Science.gov

Sample records for energy control strategy

  1. Coordinated train control and energy management control strategies

    SciTech Connect

    Gordon, S.P.; Lehrer, D.G.

    1998-05-01

    The Bay Area Rapid Transit (BART) system, in collaboration with Hughes Aircraft Company and Harmon Industries, as in the process of developing an Advanced Automatic Train Control (AATC) system to replace the current fixed-block automatic system. In the long run, the AATC system is expected to not only allow for safe short headway operation, but also to facilitate coordinated train control and energy management. This new system will employ spread spectrum radios, installed onboard trains, at wayside locations, and at control stations, to determine train locations and reliably transfer control information. Sandia National Laboratories has worked cooperatively with BART to develop a simulator of the train control and the power consumption of the AATC system. The authors are now in the process of developing enhanced train control algorithms to supplement the safety critical controller in order to smooth out train trajectories through coordinated control of multiple trains, and to reduce energy consumption and power infrastructure requirements. The control algorithms so far considered include (1) reducing peak power consumption to avoid voltage sags, especially during an outage or while clearing a backup, (2) rapid and smooth recovery from a backup, (3) avoiding oscillations due to train interference, (4) limiting needle peaks in power demand at substations to some specified level, (5) coasting, and (6) coordinating train movement, e.g., starts/stops and hills.

  2. Energy control strategy for a hybrid electric vehicle

    DOEpatents

    Phillips, Anthony Mark; Blankenship, John Richard; Bailey, Kathleen Ellen; Jankovic, Miroslava

    2002-08-27

    An energy control strategy (10) for a hybrid electric vehicle that controls an electric motor during bleed and charge modes of operation. The control strategy (10) establishes (12) a value of the power level at which the battery is to be charged. The power level is used to calculate (14) the torque to be commanded to the electric motor. The strategy (10) of the present invention identifies a transition region (22) for the electric motor's operation that is bounded by upper and lower speed limits. According to the present invention, the desired torque is calculated by applying equations to the regions before, during and after the transition region (22), the equations being a function of the power level and the predetermined limits and boundaries.

  3. Energy control strategy for a hybrid electric vehicle

    DOEpatents

    Phillips, Anthony Mark; Blankenship, John Richard; Bailey, Kathleen Ellen; Jankovic, Miroslava

    2002-01-01

    An energy control strategy (10) for a hybrid electric vehicle that controls an electric motor during bleed and charge modes of operation. The control strategy (10) establishes (12) a value of the power level at which the battery is to be charged. The power level is used to calculate (14) the torque to be commanded to the electric motor. The strategy (10) of the present invention identifies a transition region (22) for the electric motor's operation that is bounded by upper and lower speed limits. According to the present invention, the desired torque is calculated by applying equations to the regions before, during and after the transition region (22), the equations being a function of the power level and the predetermined limits and boundaries.

  4. Real Time Energy Management Control Strategies for Hybrid Powertrains

    NASA Astrophysics Data System (ADS)

    Zaher, Mohamed Hegazi Mohamed

    In order to improve fuel efficiency and reduce emissions of mobile vehicles, various hybrid power-train concepts have been developed over the years. This thesis focuses on embedded control of hybrid powertrain concepts for mobile vehicle applications. Optimal robust control approach is used to develop a real time energy management strategy for continuous operations. The main idea is to store the normally wasted mechanical regenerative energy in energy storage devices for later usage. The regenerative energy recovery opportunity exists in any condition where the speed of motion is in opposite direction to the applied force or torque. This is the case when the vehicle is braking, decelerating, or the motion is driven by gravitational force, or load driven. There are three main concepts for regernerative energy storing devices in hybrid vehicles: electric, hydraulic, and flywheel. The real time control challenge is to balance the system power demand from the engine and the hybrid storage device, without depleting the energy storage device or stalling the engine in any work cycle, while making optimal use of the energy saving opportunities in a given operational, often repetitive cycle. In the worst case scenario, only engine is used and hybrid system completely disabled. A rule based control is developed and tuned for different work cycles and linked to a gain scheduling algorithm. A gain scheduling algorithm identifies the cycle being performed by the machine and its position via GPS, and maps them to the gains.

  5. A new energy optimizing control strategy for switched reluctance motors

    SciTech Connect

    Kjaer, P.C.; Nielsen, P.

    1995-09-01

    This paper describes a new and machine-independent method to minimize the energy consumption of a speed controlled Switched Reluctance Motor (SRM). The control strategy is to vary the duty cycle of the applied dc voltage in order to obtain the desired speed quickly and when operating in steady-state vary the turn-on angle ({alpha}{sub on}) of the phase voltage to minimize the energy consumption. The power flow is measured in the dc-link and used to control the turn-on angle. Simulations carried out on a three-phase 6/4 pole SRM justify the algorithm and the physical implementation in a Siemens SAB 80C517A microcontroller is described. Measurements on two different load systems show it is possible to minimize the energy consumption on-line in a speed controlled Switched Reluctance Motor without losing the dynamic performance. A comparison with an ordinary mode-shift controlled SRM shows more than an 8% increase in overall efficiency for some operation points. The algorithm is fully applicable to other Switched Reluctance Motors at other power levels or with other pole configurations.

  6. Optimal control strategies for hydrogen production when coupling solid oxide electrolysers with intermittent renewable energies

    NASA Astrophysics Data System (ADS)

    Cai, Qiong; Adjiman, Claire S.; Brandon, Nigel P.

    2014-12-01

    The penetration of intermittent renewable energies requires the development of energy storage technologies. High temperature electrolysis using solid oxide electrolyser cells (SOECs) as a potential energy storage technology, provides the prospect of a cost-effective and energy efficient route to clean hydrogen production. The development of optimal control strategies when SOEC systems are coupled with intermittent renewable energies is discussed. Hydrogen production is examined in relation to energy consumption. Control strategies considered include maximizing hydrogen production, minimizing SOEC energy consumption and minimizing compressor energy consumption. Optimal control trajectories of the operating variables over a given period of time show feasible control for the chosen situations. Temperature control of the SOEC stack is ensured via constraints on the overall temperature difference across the cell and the local temperature gradient within the SOEC stack, to link materials properties with system performance; these constraints are successfully managed. The relative merits of the optimal control strategies are analyzed.

  7. Investigation of energy management strategies for photovoltaic systems - A predictive control algorithm

    NASA Technical Reports Server (NTRS)

    Cull, R. C.; Eltimsahy, A. H.

    1983-01-01

    The present investigation is concerned with the formulation of energy management strategies for stand-alone photovoltaic (PV) systems, taking into account a basic control algorithm for a possible predictive, (and adaptive) controller. The control system controls the flow of energy in the system according to the amount of energy available, and predicts the appropriate control set-points based on the energy (insolation) available by using an appropriate system model. Aspects of adaptation to the conditions of the system are also considered. Attention is given to a statistical analysis technique, the analysis inputs, the analysis procedure, and details regarding the basic control algorithm.

  8. Advanced Control Technologies and Strategies Linking DemandResponse and Energy Efficiency

    SciTech Connect

    Kiliccote, Sila; Piette, Mary Ann

    2005-09-02

    This paper presents a preliminary framework to describe how advanced controls can support multiple modes of operations including both energy efficiency and demand response (DR). A general description of DR, its benefits, and nationwide status is outlined. The role of energy management and control systems for DR is described. Building systems such as HVAC and lighting that utilize control technologies and strategies for energy efficiency are mapped on to DR and demand shedding strategies are developed. Past research projects are presented to provide a context for the current projects. The economic case for implementing DR from a building owner perspective is also explored.

  9. Energy savings and economics of advanced control strategies for packaged air conditioners with gas heat

    SciTech Connect

    Wang, Weimin; Katipamula, Srinivas; Huang, Yunzhi; Brambley, Michael R.

    2013-10-01

    This paper presents an evaluation of the potential energy savings from adding advanced control to existing packaged air conditioners. Advanced control options include air-side economizer, multi-speed fan control, demand control ventilation and staged cooling. The energy and cost savings from the different control strategies individually and in combination are estimated using the EnergyPlus detailed energy simulation program for four building types, namely, a small office building, a stand-alone retail building, a strip mall building and a supermarket building. For each of the four building types, the simulation was run for 16 locations covering all 15 climate zones in the U.S. The maximum installed cost of a replacement controller that provides acceptable payback periods to owners is estimated.

  10. Effect of switching control strategies on the energy performance of electrochromic windows

    SciTech Connect

    Sullivan, R.; Lee, E.S.; Papamichael, K.; Rubin, M.; Selkowitz, S.

    1994-04-01

    This paper presents the results of a study investigating the energy performance of electrochromic windows under a variety of state-switching control strategies. The authors used the DOE-2.1E energy simulation program to analyze the annual cooling, lighting, and total electricity use and peak demand as a function of glazing type, size, and electrochromic control strategy. They simulated a prototypical commercial office building module located in the cooling-dominated location of Blythe, California. Control strategies analyzed were based on daylight illuminance, incident total solar radiation, and space cooling load. Their results show that when a daylighting strategy is used to reduce electrical lighting requirements, control algorithms based on daylight illuminance results in the best overall annual energy performance. If daylighting is not a design option, controls based on space cooling load yield the best performance through solar heat gain reduction. The performance of the incident total solar radiation control strategies varies as a function of the values of solar radiation which trigger the bleached and colored states of the electrochromic (setpoint range); for small to moderate window sizes which result in small to moderate solar gains, a large setpoint-range was best since it provides increased illuminance for daylighting without much cooling penalty; for larger window sizes, which provide adequate daylight, a small setpoint-range was best to reduce unwanted solar heat gains and the consequential increased cooling requirement. Of particular importance is the fact that reduction in peak electric demand was found to be independent of the type of control strategy used for electrochromic switching. This is because the electrochromics are generally in their most colored state under peak conditions, and the mechanism used for achieving such a state is not important.

  11. The impact of demand-controlled and economizer ventilation strategies on energy use in buildings

    SciTech Connect

    Brandemuehl, M.J.; Braun, J.E.

    1999-07-01

    The overall objective of this work was to evaluate typical energy requirements associated with alternative ventilation control strategies for constant-air-volume (CAV) systems in commercial buildings. The strategies included different combinations of economizer and demand-controlled ventilation, and energy analyses were performed for four typical building types, eight alternative ventilation systems, and twenty US climates. Only single-zone buildings were considered so that simultaneous heating and cooling did not exist. The energy savings associated with economizer and demand-controlled ventilation strategies were found to be very significant for both heating and cooling. In general, the greatest savings in electrical usage for cooling with the addition of demand-controlled ventilation occur in situations where the opportunities for economizer cooling are less. This is true for warm and humid climates and for buildings that have relatively low internal gains (i.e., low occupant densities). As much as 20% savings in electrical energy for cooling were possible with demand-controlled ventilation. The savings in heating energy associated with demand-controlled ventilation were generally much larger but were strongly dependent upon the building type and occupancy schedule. Significantly greater savings were found for buildings with highly variable occupancy schedules and large internal gains (i.e., restaurants) as compared with office buildings. In some cases, the primary heating energy was virtually eliminated by demand-controlled ventilation as compared with fixed ventilation rates. For both heating and cooling, the savings associated with demand-controlled ventilation are dependent on the fixed minimum ventilation rate of the base case at design conditions.

  12. Control strategies to optimise power output in heave buoy energy convertors

    NASA Astrophysics Data System (ADS)

    Abu Zarim, M. A. U. A.; Sharip, R. M.

    2013-12-01

    Wave energy converter (WEC) designs are always discussed in order to obtain an optimum design to generate the power from the wave. Output power from wave energy converter can be improved by controlling the oscillation in order to acquire the interaction between the WEC and the incident wave.The purpose of this research is to study the heave buoys in the interest to generate an optimum power output by optimising the phase control and amplitude in order to maximise the active power. In line with the real aims of this study which investigate the theory and function and hence optimise the power generation of heave buoys as renewable energy sources, the condition that influence the heave buoy must be understand in which to propose the control strategies that can be use to control parameters to obtain optimum power output. However, this research is in an early stage, and further analysis and technical development is require.

  13. Demand Responsive and Energy Efficient Control Technologies andStrategies in Commercial Buildings

    SciTech Connect

    Piette, Mary Ann; Kiliccote, Sila

    2006-09-01

    Commercial buildings account for a large portion of summer peak electric demand. Research results show that there is significant potential to reduce peak demand in commercial buildings through advanced control technologies and strategies. However, a better understanding of commercial buildings contribution to peak demand and the use of energy management and control systems is required to develop this demand response resource to its full potential. The main objectives of the study were: (1) To evaluate the size of contributions of peak demand commercial buildings in the U.S.; (2) To understand how commercial building control systems support energy efficiency and DR; and (3) To disseminate the results to the building owners, facility managers and building controls industry. In order to estimate the commercial buildings contribution to peak demand, two sources of data are used: (1) Commercial Building Energy Consumption Survey (CBECS) and (2) National Energy Modeling System (NEMS). These two sources indicate that commercial buildings noncoincidental peak demand is about 330GW. The project then focused on technologies and strategies that deliver energy efficiency and also target 5-10% of this peak. Based on a building operations perspective, a demand-side management framework with three main features: (1) daily energy efficiency, (2) daily peak load management and (3) dynamic, event-driven DR are outlined. A general description of DR, its benefits, and nationwide DR potential in commercial buildings are presented. Case studies involving these technologies and strategies are described. The findings of this project are shared with building owners, building controls industry, researchers and government entities through a webcast and their input is requested. Their input is presented in the appendix section of this report.

  14. Design and control strategy for a hybrid green energy system for mobile telecommunication sites

    NASA Astrophysics Data System (ADS)

    Okundamiya, Michael S.; Emagbetere, Joy O.; Ogujor, Emmanuel A.

    2014-07-01

    The rising energy costs and carbon footprint of operating mobile telecommunication sites in the emerging world have increased research interests in green technology. The intermittent nature of most green energy sources creates the problem of designing the optimum configuration for a given location. This study presents the design analysis and control strategy for a cost effective and reliable operation of the hybrid green energy system (HGES) for GSM base transceiver station (BTS) sites in isolated regions. The design constrains the generation and distribution of power to reliably satisfy the energy demand while ensuring safe operation of the system. The overall process control applies the genetic algorithm-based technique for optimal techno-economic sizing of system's components. The process simulation utilized meteorological data for 3 locations (Abuja, Benin City and Sokoto) with varying climatic conditions in Nigeria. Simulation results presented for green GSM BTS sites are discussed and compared with existing approaches.

  15. Control strategies on stable manifolds for energy-efficient swing-ups of double pendula

    NASA Astrophysics Data System (ADS)

    Flaßkamp, Kathrin; Timmermann, Julia; Ober-Blöbaum, Sina; Trächtler, Ansgar

    2014-09-01

    Optimal control problems for mechanical systems often arise in technical applications. To find solutions with minimal control effort, the system's natural, uncontrolled dynamics can be used. Promising candidates to be considered for energy-efficient trajectories are highly dynamic, but uncontrolled motions on (un)stable manifolds of equilibria. In this contribution, we propose a control strategy for mechanical systems which sequences uncontrolled trajectories on (un)stable manifolds with short control manoeuvres to design a feedforward control. In particular, we present optimal swing-up solutions for a double pendulum which are based on trajectories on the stable manifold of the pendulum's up-up equilibrium. To demonstrate the advantages of our approach compared to a black-box optimisation, we perform a post-optimisation with the optimal control sequence as an initial guess. The numerical results are evaluated in a simulation environment for the double pendulum on a cart and applied to a real test rig.

  16. A control strategy for a variable-speed wind energy conversion system

    NASA Astrophysics Data System (ADS)

    Jacob, A.; Rajagopalan, V.; Veillette, D.

    1980-01-01

    In this article, a method of calculating an optimal control strategy for a variable-speed wind power generation scheme incorporating a squirrel cage induction machine and operating in a self-excited induction generator mode is discussed. This scheme also uses a conventional three-phase thyristor rectifier, a line-commutated inverter and an economical auxiliary commutated-voltage-source inverter. The three regulated variables are: (1) drive speed as a function of available mechanical energy by manipulating the resistive torque developed by induction generator; (2) induction motor power consumption during start-up of the wind machine of vertical axis type; (3) operating slip of the induction machine, thereby limiting start-up and braking currents. The developed strategy is also suitable for any other variable-speed drive system incorporating an induction machine.

  17. Strategies and Decision Support Systems for Integrating Variable Energy Resources in Control Centers for Reliable Grid Operations

    SciTech Connect

    Jones, Lawrence E.

    2011-11-01

    This report provides findings from the field regarding the best ways in which to guide operational strategies, business processes and control room tools to support the integration of renewable energy into electrical grids.

  18. Strategies and Decision Support Systems for Integrating Variable Energy Resources in Control Centers for Reliable Grid Operations. Executive Summary

    SciTech Connect

    Jones, Lawrence E.

    2011-11-01

    This is the executive summary for a report that provides findings from the field regarding the best ways in which to guide operational strategies, business processes and control room tools to support the integration of renewable energy into electrical grids.

  19. FY12 annual Report: PHEV Engine Control and Energy Management Strategy

    SciTech Connect

    Chambon, Paul H

    2012-05-01

    The objectives are: (1) Investigate novel engine control strategies targeted at rapid engine/catalyst warming for the purpose of mitigating tailpipe emissions from plug-in hybrid electric vehicles (PHEV) exposed to multiple engine cold start events; (2) Optimize integration of engine control strategies with hybrid supervisory control strategies in order to reduce cold start emissions and fuel consumption of PHEVs; and (3) Ensure that development of new vehicle technologies complies with existing emission standards.

  20. An Optimal Control Strategy for DC Bus Voltage Regulation in Photovoltaic System with Battery Energy Storage

    PubMed Central

    Daud, Muhamad Zalani; Mohamed, Azah; Hannan, M. A.

    2014-01-01

    This paper presents an evaluation of an optimal DC bus voltage regulation strategy for grid-connected photovoltaic (PV) system with battery energy storage (BES). The BES is connected to the PV system DC bus using a DC/DC buck-boost converter. The converter facilitates the BES power charge/discharge to compensate for the DC bus voltage deviation during severe disturbance conditions. In this way, the regulation of DC bus voltage of the PV/BES system can be enhanced as compared to the conventional regulation that is solely based on the voltage-sourced converter (VSC). For the grid side VSC (G-VSC), two control methods, namely, the voltage-mode and current-mode controls, are applied. For control parameter optimization, the simplex optimization technique is applied for the G-VSC voltage- and current-mode controls, including the BES DC/DC buck-boost converter controllers. A new set of optimized parameters are obtained for each of the power converters for comparison purposes. The PSCAD/EMTDC-based simulation case studies are presented to evaluate the performance of the proposed optimized control scheme in comparison to the conventional methods. PMID:24883374

  1. An optimal control strategy for DC bus voltage regulation in photovoltaic system with battery energy storage.

    PubMed

    Daud, Muhamad Zalani; Mohamed, Azah; Hannan, M A

    2014-01-01

    This paper presents an evaluation of an optimal DC bus voltage regulation strategy for grid-connected photovoltaic (PV) system with battery energy storage (BES). The BES is connected to the PV system DC bus using a DC/DC buck-boost converter. The converter facilitates the BES power charge/discharge to compensate for the DC bus voltage deviation during severe disturbance conditions. In this way, the regulation of DC bus voltage of the PV/BES system can be enhanced as compared to the conventional regulation that is solely based on the voltage-sourced converter (VSC). For the grid side VSC (G-VSC), two control methods, namely, the voltage-mode and current-mode controls, are applied. For control parameter optimization, the simplex optimization technique is applied for the G-VSC voltage- and current-mode controls, including the BES DC/DC buck-boost converter controllers. A new set of optimized parameters are obtained for each of the power converters for comparison purposes. The PSCAD/EMTDC-based simulation case studies are presented to evaluate the performance of the proposed optimized control scheme in comparison to the conventional methods. PMID:24883374

  2. Cost Control Strategies for Zero Energy Buildings: High-Performance Design and Construction on a Budget (Brochure)

    SciTech Connect

    Not Available

    2014-09-01

    There is mounting evidence that zero energy can, in many cases, be achieved within typical construction budgets. To ensure that the momentum behind zero energy buildings and other low-energy buildings will continue to grow, this guide assembles recommendations for replicating specific successes of early adopters who have met their energy goals while controlling costs. Contents include: discussion of recommended cost control strategies, which are grouped by project phase (acquisition and delivery, design, and construction) and accompanied by industry examples; recommendations for balancing key decision-making factors; and quick reference tables that can help teams apply strategies to specific projects.

  3. Energy Savings and Economics of Advanced Control Strategies for Packaged Air-Conditioning Units with Gas Heat

    SciTech Connect

    Wang, Weimin; Katipamula, Srinivas; Huang, Yunzhi; Brambley, Michael R.

    2011-12-31

    Pacific Northwest National Laboratory (PNNL) with funding from the U.S. Department of Energy's Building Technologies Program (BTP) evaluated a number of control strategies that can be implemented in a controller, to improve the operational efficiency of the packaged air conditioning units. The two primary objectives of this research project are: (1) determine the magnitude of energy savings achievable by retrofitting existing packaged air conditioning units with advanced control strategies not ordinarily used for packaged units and (2) estimating what the installed cost of a replacement control with the desired features should be in various regions of the U.S. This document reports results of the study.

  4. Study of energy efficient supercritical coal-fired power plant dynamic responses and control strategies

    NASA Astrophysics Data System (ADS)

    Mohamed, Omar R. Ibrahim

    The world is facing the challenge of global warming and environment protection. On the other hand, the demand of electricity is growing fast due to economic growth and increase in population. Since the growth in demand is also a heavy factor in energy equations, then the renewable energy alone is not able to generate enough electricity to fill the gap within a short time of period. Therefore, fossil fuel such as coal fired power plants cannot be ruled out immediately due to their generation capacity and flexibility in load following. However, any new coal fired stations should be cleaner compared with traditional power plants. Supercritical power plants are one of the most suitable choices for environmental enhancement and higher efficiency. However, there has been an issue of whether or not to adopt this technology in the UK because it is not clear whether the performance for SC plants can satisfy the British Grid Code requirement. This thesis reports a study of dynamic responses of SC power plants through mathematical modelling, and simulation for Grid Code compliance. It also presents a new control strategy based on an alternative configuration of generalized predictive control for power plant control..

  5. Structuring energy supply and demand networks in a general equilibrium model to simulate global warming control strategies

    SciTech Connect

    Hamilton, S.; Veselka, T.D.; Cirillo, R.R.

    1991-01-01

    Global warming control strategies which mandate stringent caps on emissions of greenhouse forcing gases can substantially alter a country's demand, production, and imports of energy products. Although there is a large degree of uncertainty when attempting to estimate the potential impact of these strategies, insights into the problem can be acquired through computer model simulations. This paper presents one method of structuring a general equilibrium model, the ENergy and Power Evaluation Program/Global Climate Change (ENPEP/GCC), to simulate changes in a country's energy supply and demand balance in response to global warming control strategies. The equilibrium model presented in this study is based on the principle of decomposition, whereby a large complex problem is divided into a number of smaller submodules. Submodules simulate energy activities and conversion processes such as electricity production. These submodules are linked together to form an energy supply and demand network. Linkages identify energy and fuel flows among various activities. Since global warming control strategies can have wide reaching effects, a complex network was constructed. The network represents all energy production, conversion, transportation, distribution, and utilization activities. The structure of the network depicts interdependencies within and across economic sectors and was constructed such that energy prices and demand responses can be simulated. Global warming control alternatives represented in the network include: (1) conservation measures through increased efficiency; and (2) substitution of fuels that have high greenhouse gas emission rates with fuels that have lower emission rates. 6 refs., 4 figs., 4 tabs.

  6. Supervisory Control Strategy Development

    SciTech Connect

    Gary D. Storrick; Bojan Petrovic

    2007-02-28

    Task 4 of this collaborative effort between ORNL, Brazil, and Westinghouse for the International Nuclear Energy Research Initiative entitled “Development of Advanced Instrumentation and Control for an Integrated Primary System Reactor” focused on the design of the hierarchical supervisory control for multiple-module units. The state of the IRIS plant design – specifically, the lack of a detailed secondary system design – made developing a detailed hierarchical control difficult at this time. However, other simultaneous and ongoing efforts have contributed to providing the needed information. This report summarizes the results achieved under Task 4 of this Financial Assistance Award. Section 1.2 describes the scope of this effort. Section 2 discusses the IRIS control functions. Next, it briefly reviews the current control concepts, and then reviews the maneuvering requirements for the IRIS plant. It closes by noting the benefits that automated sequences have in reducing operator workload. Section 3 examines reactor loading in the frequency domain to establish some guidelines for module operation, paying particular attention to strategies for using process steam for desalination and/or district heating. The final subsection discusses the implications for reactor control, and argues that using the envisioned percentage (up to 10%) of the NSSS thermal output for these purposes should not significantly affect the NSSS control strategies. Section 4 uses some very general economic assumptions to suggest how one should approach multi-module operation. It concludes that the well-known algorithms used for economic dispatching could be used to help manage a multi-unit IRIS site. Section 5 addresses the human performance factors of multi-module operation. Section 6 summarizes our conclusions.

  7. FY11 annual Report: PHEV Engine Control and Energy Management Strategy

    SciTech Connect

    Chambon, Paul H

    2011-10-01

    Objectives are to: (1) Investigate novel engine control strategies targeted at rapid engine/catalyst warming for the purpose of mitigating tailpipe emissions from plug-in hybrid electric vehicles (PHEV) exposed to multiple engine cold start events; and (2) Validate and optimize hybrid supervisory control techniques developed during previous and on-going research projects by integrating them into the vehicle level control system and complementing them with the modified engine control strategies in order to further reduce emissions during both cold start and engine re-starts. Approach used are: (1) Perform a literature search of engine control strategies used in conventional powertrains to reduce cold start emissions; (2) Develop an open source engine controller providing full access to engine control strategies in order to implement new engine/catalyst warm-up behaviors; (3) Modify engine cold start control algorithms and characterize impact on cold start behavior; and (4) Develop an experimental Engine-In-the-Loop test stand in order to validate control methodologies and verify transient thermal behavior and emissions of the real engine when combined with a virtual hybrid powertrain. Some major accomplishments are: (1) Commissioned a prototype engine controller on a GM Ecotec 2.4l direct injected gasoline engine on an engine test cell at the University of Tennessee. (2) Obtained from Bosch (with GM's approval) an open calibration engine controller for a GM Ecotec LNF 2.0l Gasoline Turbocharged Direct Injection engine. Bosch will support the bypass of cold start strategies if calibration access proves insufficient. The LNF engine and its open controller were commissioned on an engine test cell at ORNL. (3) Completed a literature search to identify key engine cold start control parameters and characterized their impact on the real engine using the Bosch engine controller to calibrate them. (4) Ported virtual hybrid vehicle model from offline simulation environment to

  8. Energy Savings and Economics of Advanced Control Strategies for Packaged Heat Pumps

    SciTech Connect

    Wang, Weimin; Huang, Yunzhi; Katipamula, Srinivas

    2012-10-31

    Pacific Northwest National Laboratory (PNNL), with funding from the U.S. Department of Energy’s (DOE’s) Building Technologies Program (BTP), evaluated a number of control strategies for packaged cooling equipment that can be implemented in an advanced controller, which can be retrofit into existing packaged heat pump units to improve their operational efficiency. This report documents the results of that analysis.

  9. Control strategy for a variable-speed wind energy conversion system

    NASA Technical Reports Server (NTRS)

    Jacob, A.; Veillette, D.; Rajagopalan, V.

    1979-01-01

    A control concept for a variable-speed wind energy conversion system is proposed, for which a self-exited asynchronous cage generator is used along with a system of thyristor converters. The control loops are the following: (1) regulation of the entrainment speed as function of available mechanical energy by acting on the resistance couple of the asynchronous generator; (2) control of electric power delivered to the asynchronous machine, functioning as a motor, for start-up of the vertical axis wind converter; and (3) limitation of the slip value, and by consequence, of the induction currents in the presence of sudden variations of input parameters.

  10. World Energy Strategies

    ERIC Educational Resources Information Center

    Lovins, Amory B.

    1974-01-01

    Examines possible energy options and outlines assessments and conclusions influencing recent top level energy thinking and planning. Indicates that no nation on earth appears to have either a coherent long-range energy strategy or the institutions needed to devise one. (JR)

  11. An energy-saving nonlinear position control strategy for electro-hydraulic servo systems.

    PubMed

    Baghestan, Keivan; Rezaei, Seyed Mehdi; Talebi, Heidar Ali; Zareinejad, Mohammad

    2015-11-01

    The electro-hydraulic servo system (EHSS) demonstrates numerous advantages in size and performance compared to other actuation methods. Oftentimes, its utilization in industrial and machinery settings is limited by its inferior efficiency. In this paper, a nonlinear backstepping control algorithm with an energy-saving approach is proposed for position control in the EHSS. To achieve improved efficiency, two control valves including a proportional directional valve (PDV) and a proportional relief valve (PRV) are used to achieve the control objectives. To design the control algorithm, the state space model equations of the system are transformed to their normal form and the control law through the PDV is designed using a backstepping approach for position tracking. Then, another nonlinear set of laws is derived to achieve energy-saving through the PRV input. This control design method, based on the normal form representation, imposes internal dynamics on the closed-loop system. The stability of the internal dynamics is analyzed in special cases of operation. Experimental results verify that both tracking and energy-saving objectives are satisfied for the closed-loop system. PMID:26520165

  12. Comprehensive national energy strategy

    SciTech Connect

    1998-04-01

    This Comprehensive National Energy Strategy sets forth a set of five common sense goals for national energy policy: (1) improve the efficiency of the energy system, (2) ensure against energy disruptions, (3) promote energy production and use in ways that respect health and environmental values, (4) expand future energy choices, and (5) cooperate internationally on global issues. These goals are further elaborated by a series of objectives and strategies to illustrate how the goals will be achieved. Taken together, the goals, objectives, and strategies form a blueprint for the specific programs, projects, initiatives, investments, and other actions that will be developed and undertaken by the Federal Government, with significant emphasis on the importance of the scientific and technological advancements that will allow implementation of this Comprehensive National Energy Strategy. Moreover, the statutory requirement of regular submissions of national energy policy plans ensures that this framework can be modified to reflect evolving conditions, such as better knowledge of our surroundings, changes in energy markets, and advances in technology. This Strategy, then, should be thought of as a living document. Finally, this plan benefited from the comments and suggestions of numerous individuals and organizations, both inside and outside of government. The Summary of Public Comments, located at the end of this document, describes the public participation process and summarizes the comments that were received. 8 figs.

  13. Numerical Laser Energy Deposition on Supersonic Cavity Flow and Sensor Placement Strategies to Control the Flow

    PubMed Central

    Aradag, Selin

    2013-01-01

    In this study, the impact of laser energy deposition on pressure oscillations and relative sound pressure levels (SPL) in an open supersonic cavity flow is investigated. Laser energy with a magnitude of 100 mJ is deposited on the flow just above the cavity leading edge and up to 7 dB of reduction is obtained in the SPL values along the cavity back wall. Additionally, proper orthogonal decomposition (POD) method is applied to the x-velocity data obtained as a result of computational fluid dynamics simulations of the flow with laser energy deposition. Laser is numerically modeled using a spherically symmetric temperature distribution. By using the POD results, the effects of laser energy on the flow mechanism are presented. A one-dimensional POD methodology is applied to the surface pressure data to obtain critical locations for the placement of sensors for real time flow control applications. PMID:24363612

  14. Numerical laser energy deposition on supersonic cavity flow and sensor placement strategies to control the flow.

    PubMed

    Yilmaz, Ibrahim; Aradag, Selin

    2013-01-01

    In this study, the impact of laser energy deposition on pressure oscillations and relative sound pressure levels (SPL) in an open supersonic cavity flow is investigated. Laser energy with a magnitude of 100 mJ is deposited on the flow just above the cavity leading edge and up to 7 dB of reduction is obtained in the SPL values along the cavity back wall. Additionally, proper orthogonal decomposition (POD) method is applied to the x-velocity data obtained as a result of computational fluid dynamics simulations of the flow with laser energy deposition. Laser is numerically modeled using a spherically symmetric temperature distribution. By using the POD results, the effects of laser energy on the flow mechanism are presented. A one-dimensional POD methodology is applied to the surface pressure data to obtain critical locations for the placement of sensors for real time flow control applications. PMID:24363612

  15. Control Strategies for Smoothing of Output Power of Wind Energy Conversion Systems

    NASA Astrophysics Data System (ADS)

    Pratap, Alok; Urasaki, Naomitsu; Senju, Tomonobu

    2013-10-01

    This article presents a control method for output power smoothing of a wind energy conversion system (WECS) with a permanent magnet synchronous generator (PMSG) using the inertia of wind turbine and the pitch control. The WECS used in this article adopts an AC-DC-AC converter system. The generator-side converter controls the torque of the PMSG, while the grid-side inverter controls the DC-link and grid voltages. For the generator-side converter, the torque command is determined by using the fuzzy logic. The inputs of the fuzzy logic are the operating point of the rotational speed of the PMSG and the difference between the wind turbine torque and the generator torque. By means of the proposed method, the generator torque is smoothed, and the kinetic energy stored by the inertia of the wind turbine can be utilized to smooth the output power fluctuations of the PMSG. In addition, the wind turbines shaft stress is mitigated compared to a conventional maximum power point tracking control. Effectiveness of the proposed method is verified by the numerical simulations.

  16. Energy savings from indirect evaporative pre-cooling: Control strategies and commissioning

    SciTech Connect

    Felts, D.; Jump, D.A.

    1998-07-01

    Package rooftop air conditioning units (RTU) with evaporative pre-cooling systems were installed at an Agricultural History Museum and conference center in the northern Sacramento Valley in California, a hot and dry summer climate region. The evaporative pre-coolers serve to extend the economizer range of the RTU's. A commissioning team monitored the performance of the RTU evaporative pre-coolers. The purpose of the monitoring was to determine if changes were warranted to optimize the system's energy efficiency. The commissioning process revealed that the RTU evaporative pre-coolers were being controlled by the economizer control cycle. With this control cycle, the evaporative pre-cooler operates when the outdoor air temperature is falling below the space return air temperature. This means that the pre-cooler will never operate at peak load conditions. The conference center is an assembly occupancy. Building codes require significant levels of outdoor air for ventilation. The evaporative pre-cooler system provides the means to significantly offset the energy requirements for cooling down and heating up this ventilation air. A DOE2 energy simulation analysis indicated that the evaporative pre-cooler could cut energy use by over 50% if it were working correctly. Investigation concludes that in buildings with high outdoor air requirements, evaporative pre-cooling, using building exhaust air as the indirect evaporative cooling source, significantly reduce building energy consumption. This evaporative pre-cooling technology works in any climate, regardless of outdoor conditions, since the return air stream exhausted from the building provides a relatively constant temperature and humidity source for evaporative cooling. An added benefit is that the evaporative pre-cooler heat exchanger recovers heat from the exhausted air stream in cold weather.

  17. Energy-aware topology control strategy for human-centric wireless sensor networks.

    PubMed

    Meseguer, Roc; Molina, Carlos; Ochoa, Sergio F; Santos, Rodrigo

    2014-01-01

    The adoption of mobile and ubiquitous solutions that involve participatory or opportunistic sensing increases every day. This situation has highlighted the relevance of optimizing the energy consumption of these solutions, because their operation depends on the devices' battery lifetimes. This article presents a study that intends to understand how the prediction of topology control messages in human-centric wireless sensor networks can be used to help reduce the energy consumption of the participating devices. In order to do that, five research questions have been defined and a study based on simulations was conducted to answer these questions. The obtained results help identify suitable mobile computing scenarios where the prediction of topology control messages can be used to save energy of the network nodes. These results also allow estimating the percentage of energy saving that can be expected, according to the features of the work scenario and the participants behavior. Designers of mobile collaborative applications that involve participatory or opportunistic sensing, can take advantage of these findings to increase the autonomy of their solutions. PMID:24514884

  18. Energy-Aware Topology Control Strategy for Human-Centric Wireless Sensor Networks

    PubMed Central

    Meseguer, Roc; Molina, Carlos; Ochoa, Sergio F.; Santos, Rodrigo

    2014-01-01

    The adoption of mobile and ubiquitous solutions that involve participatory or opportunistic sensing increases every day. This situation has highlighted the relevance of optimizing the energy consumption of these solutions, because their operation depends on the devices' battery lifetimes. This article presents a study that intends to understand how the prediction of topology control messages in human-centric wireless sensor networks can be used to help reduce the energy consumption of the participating devices. In order to do that, five research questions have been defined and a study based on simulations was conducted to answer these questions. The obtained results help identify suitable mobile computing scenarios where the prediction of topology control messages can be used to save energy of the network nodes. These results also allow estimating the percentage of energy saving that can be expected, according to the features of the work scenario and the participants behavior. Designers of mobile collaborative applications that involve participatory or opportunistic sensing, can take advantage of these findings to increase the autonomy of their solutions. PMID:24514884

  19. Use of the Edmonds-Reilly Model to model energy-sector impacts of greenhouse gas emissions control strategies

    SciTech Connect

    Barns, D.W.; Edmonds, J.A.; Reilly, J.M.

    1992-01-01

    The purpose of this paper is to document the results of our application of the Edmonds-Reilly Model (ERM) using several scenarios provided in connection with the 1991 Energy Modeling Forum (EMF). The purpose of this session of the forum is to compare the efforts of several modeling teams using common assumptions to examine the energy sector impacts of strategies to control greenhouse gas emissions. Because the output of this exercise is data-rich, most of this exposition is in graphical form with the narrative serving mainly as a roadmap for moving from one highlight to the next. The following sessions briefly describe the model and some of the special modifications made for this effort. The case-by-case discussion is contained in Section IV, followed by a summary of the potential pitfalls involved in attempting to assess the cost of emissions reduction from the model data.

  20. An Energy Storage Assessment: Using Optimal Control Strategies to Capture Multiple Services

    SciTech Connect

    Wu, Di; Jin, Chunlian; Balducci, Patrick J.; Kintner-Meyer, Michael CW

    2015-09-01

    This paper presents a methodology for evaluating benefits of battery storage for multiple grid applications, including energy arbitrage, balancing service, capacity value, distribution system equipment deferral, and outage mitigation. In the proposed method, at each hour, a look-ahead optimization is first formulated and solved to determine battery base operating point. The minute by minute simulation is then performed to simulate the actual battery operation. This methodology is used to assess energy storage alternatives in Puget Sound Energy System. Different battery storage candidates are simulated for a period of one year to assess different value streams and overall benefits, as part of a financial feasibility evaluation of battery storage projects.

  1. Effect of operating-point-control strategy on the annual energy production of degraded photovoltaic arrays

    NASA Astrophysics Data System (ADS)

    Branz, H. M.

    1982-09-01

    A new computer simulation of the annual operation of degraded flat-plate photovoltaic (PV) arrays is used to evaluate the need for maximum-power-point tracking in real PV systems. The simulations are based on single-glitch I-V curve shapes rather than particular array degradations, making the data reported applicable to any system whose likely failure modes are predictable and result in single-glitch I-V curves. The simulations show that with a reasonable array wiring strategy, effective maintenance, periodic I-V curve tracing, and avoidance of frequent and serious array shadowing, there is no reason that considerations of degradation should force the adoption of maximum-power-point-tracking power conditioning on a PV system that would otherwise operate economically at fixed voltage.

  2. National Drug Control Strategy, 2011

    ERIC Educational Resources Information Center

    Office of National Drug Control Policy, 2011

    2011-01-01

    In May of 2010, President Obama released the Administration's inaugural "National Drug Control Strategy". Based on the premise that drug use and its consequences pose a threat not just to public safety, but also to public health, the 2010 "Strategy" represented the first comprehensive rebalancing of Federal drug control policy in the nearly 40…

  3. New process modeling [sic], design, and control strategies for energy efficiency, high product quality, and improved productivity in the process industries. Final project report

    SciTech Connect

    Ray, W. Harmon

    2002-06-05

    This project was concerned with the development of process design and control strategies for improving energy efficiency, product quality, and productivity in the process industries. In particular, (i) the resilient design and control of chemical reactors, and (ii) the operation of complex processing systems, was investigated. Specific topics studied included new process modeling procedures, nonlinear controller designs, and control strategies for multiunit integrated processes. Both fundamental and immediately applicable results were obtained. The new design and operation results from this project were incorporated into computer-aided design software and disseminated to industry. The principles and design procedures have found their way into industrial practice.

  4. Introduction to Cost Control Strategies for Zero Energy Buildings: High-Performance Design and Construction on a Budget (Fact Sheet)

    SciTech Connect

    Not Available

    2014-09-01

    Momentum behind zero energy building design and construction is increasing, presenting a tremendous opportunity for advancing energy performance in the commercial building industry. At the same time, there is a lingering perception that zero energy buildings must be cost prohibitive or limited to showcase projects. Fortunately, an increasing number of projects are demonstrating that high performance can be achieved within typical budgets. This factsheet highlights replicable, recommended strategies for achieving high performance on a budget, based on experiences from past projects.

  5. Hawaii Energy Strategy: Program guide

    SciTech Connect

    Not Available

    1992-09-01

    The Hawaii Energy Strategy program, or HES, is a set of seven projects which will produce an integrated energy strategy for the State of Hawaii. It will include a comprehensive energy vulnerability assessment with recommended courses of action to decrease Hawaii`s energy vulnerability and to better prepare for an effective response to any energy emergency or supply disruption. The seven projects are designed to increase understanding of Hawaii`s energy situation and to produce recommendations to achieve the State energy objectives of: Dependable, efficient, and economical state-wide energy systems capable of supporting the needs of the people, and increased energy self-sufficiency. The seven projects under the Hawaii Energy Strategy program include: Project 1: Develop Analytical Energy Forecasting Model for the State of Hawaii. Project 2: Fossil Energy Review and Analysis. Project 3: Renewable Energy Resource Assessment and Development Program. Project 4: Demand-Side Management Program. Project 5: Transportation Energy Strategy. Project 6: Energy Vulnerability Assessment Report and Contingency Planning. Project 7: Energy Strategy Integration and Evaluation System.

  6. National Drug Control Strategy. Update

    ERIC Educational Resources Information Center

    Office of National Drug Control Policy, 2005

    2005-01-01

    The first National Drug Control Strategy set ambitious two and five-year performance based goals: (1) to lower the rate of drug use by 10 percent over 2 years among both youth and adults; and (2) to lower the rate by 25 percent over 5 years. The chapters in this updated version are keyed to the strategies three priorities: (1) Stopping Use Before…

  7. National Drug Control Strategy. Update.

    ERIC Educational Resources Information Center

    Office of National Drug Control Policy, Washington, DC.

    President Bush's new National Drug Control Strategy for 2003 focuses on three core priorities: stopping drug use before it starts; healing America's drug users; and disrupting the market. The 2003 strategy reports progress toward meeting the President's goals of reducing drug use by 10 percent over 2 years, and 25 percent over 5 years. With regard…

  8. Strategies for Energy Use.

    ERIC Educational Resources Information Center

    Gibbons, John H.; And Others

    1989-01-01

    Discusses the efficient use of energy. Compares reserves and pollutants generated by natural gas, oil, and coal. Points out some alternative energy sources and ways for improving energy efficiency in buildings, industrial processes, and transportation. Describes some problems in developing and developed countries. (YP)

  9. Lighting Control Energy Savings

    Energy Science and Technology Software Center (ESTSC)

    1985-01-01

    CONTROLITE 1.0 is a lighting energy analysis program designed to calculate the energy savings and cost benefits obtainable using lighting controls in buildings. The program can compute the lighting energy reductions that result from using daylighting, scheduling, and other control strategies. When modeling daylight control systems, the program uses QUICKLITE to compute the daylight illuminances at specified points 5 times a day, 12 days a year (the 21st of each month), and for two skymore » conditions (clear and overcast skies). Fourier series techniques are used to fit a continuous curve through the computed illuminance points. The energy use for each of the 12 days is then computed given user-specified power-in/light-out characteristics of the modeled control system. The monthly and annual energy usage for overcast and clear conditions are found separately by fitting two long-term Fourier series curves to the energy use computed for each of the 12 days. Finally, the monthly energy use is calculated by taking a weighted average for the monthly energy use computed for the overcast and clear sky conditions. The program only treats the energy use directly attributable to lighting. The impact of lighting control strategies on building thermal loads is not computed. The program allows input of different control schedules (i.e., on/off times for the lighting system) for each day of the week, but every week of the year is treated the same; thus, holidays cannot be modeled explicitly. When used for daylighting purposes, CONTROLITE1.0 understands only clear and overcast conditions. User-supplied values for the proportion of clear and overcast hours for each month of the year are required to accommodate different climatic conditions.« less

  10. National Drug Control Strategy, 2006

    ERIC Educational Resources Information Center

    The White House, 2006

    2006-01-01

    This report presents a summary of the Fiscal Year 2007 Budget for the National Drug Control Strategy within the three key priority areas; education and community action, treatment and intervention, and disruption in the illegal drug market. The first chapter, "Stopping Drug Use Before It Starts," outlines the Administration's work to prevent the…

  11. Analysis of pilot control strategy

    NASA Technical Reports Server (NTRS)

    Heffley, R. K.; Hanson, G. D.; Jewell, W. F.; Clement, W. F.

    1983-01-01

    Methods for nonintrusive identification of pilot control strategy and task execution dynamics are presented along with examples based on flight data. The specific analysis technique is Nonintrusive Parameter Identification Procedure (NIPIP), which is described in a companion user's guide (NASA CR-170398). Quantification of pilot control strategy and task execution dynamics is discussed in general terms followed by a more detailed description of how NIPIP can be applied. The examples are based on flight data obtained from the NASA F-8 digital fly by wire airplane. These examples involve various piloting tasks and control axes as well as a demonstration of how the dynamics of the aircraft itself are identified using NIPIP. Application of NIPIP to the AFTI/F-16 flight test program is discussed. Recommendations are made for flight test applications in general and refinement of NIPIP to include interactive computer graphics.

  12. Hawaii energy strategy report, October 1995

    SciTech Connect

    1995-10-01

    This is a report on the Hawaii Energy Strategy Program. The topics of the report include the a description of the program including an overview, objectives, policy statement and purpose and objectives; energy strategy policy development; energy strategy projects; current energy situation; modeling Hawaii`s energy future; energy forecasts; reducing energy demand; scenario assessment, and recommendations.

  13. Hawaii energy strategy: Executive summary, October 1995

    SciTech Connect

    1995-10-01

    This is an executive summary to a report on the Hawaii Energy Strategy Program. The topics of the report include the a description of the program including an overview, objectives, policy statement and purpose and objectives; energy strategy policy development; energy strategy projects; current energy situation; modeling Hawaii`s energy future; energy forecasts; reducing energy demand; scenario assessment, and recommendations.

  14. Neural Control of Energy Expenditure.

    PubMed

    Münzberg, Heike; Qualls-Creekmore, Emily; Berthoud, Hans-Rudolf; Morrison, Christopher D; Yu, Sangho

    2016-01-01

    The continuous rise in obesity is a major concern for future healthcare management. Many strategies to control body weight focus on a permanent modification of food intake with limited success in the long term. Metabolism or energy expenditure is the other side of the coin for the regulation of body weight, and strategies to enhance energy expenditure are a current focus for obesity treatment, especially since the (re)-discovery of the energy depleting brown adipose tissue in adult humans. Conversely, several human illnesses like neurodegenerative diseases, cancer, or autoimmune deficiency syndrome suffer from increased energy expenditure and severe weight loss. Thus, strategies to modulate energy expenditure to target weight gain or loss would improve life expectancies and quality of life in many human patients. The aim of this book chapter is to give an overview of our current understanding and recent progress in energy expenditure control with specific emphasis on central control mechanisms. PMID:26578523

  15. Neural Control of Energy Expenditure

    PubMed Central

    Qualls-Creekmore, Emily; Berthoud, Hans-Rudolf; Morrison, Christopher D.; Yu, Sangho

    2016-01-01

    The continuous rise in obesity is a major concern for future healthcare management. Many strategies to control body weight focus on a permanent modification of food intake with limited success in the long term. Metabolism or energy expenditure is the other side of the coin for the regulation of body weight, and strategies to enhance energy expenditure are a current focus for obesity treatment, especially since the (re)-discovery of the energy depleting brown adipose tissue in adult humans. Conversely, several human illnesses like neurodegenerative diseases, cancer, or autoimmune deficiency syndrome suffer from increased energy expenditure and severe weight loss. Thus, strategies to modulate energy expenditure to target weight gain or loss would improve life expectancies and quality of life in many human patients. The aim of this book chapter is to give an overview of our current understanding and recent progress in energy expenditure control with specific emphasis on central control mechanisms. PMID:26578523

  16. Environmental Strategies for Portion Control in Children

    PubMed Central

    Robinson, Thomas N.; Matheson, Donna M.

    2015-01-01

    Evidence from laboratory and field studies indicates that large portions lead to greater food and energy intake relative to small portions. However, most children and adults demonstrate limited abilities to estimate and control the amounts of food they serve and consume. Five potential environmental strategies appear promising for improving portion control in children: (1) using tall, thin, and small volume glasses and mugs, (2) using smaller diameter and volume plates, bowls and serving utensils, (3) using plates with rims, (4) reducing total television and other screen watching and (5) reducing or eliminating eating while watching television and/or other screens. Further experimental research in real world settings is needed to test these interventions as strategies for portion control and their roles in prevention and treatment of obesity. PMID:25485874

  17. 40 CFR 52.07 - Control strategies.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Control strategies. 52.07 Section 52.07... PROMULGATION OF IMPLEMENTATION PLANS General Provisions § 52.07 Control strategies. (a) Each subpart specifies in what respects the control strategies are approved or disapproved. Where emission limitations...

  18. 40 CFR 52.07 - Control strategies.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control strategies. 52.07 Section 52.07... PROMULGATION OF IMPLEMENTATION PLANS General Provisions § 52.07 Control strategies. (a) Each subpart specifies in what respects the control strategies are approved or disapproved. Where emission limitations...

  19. 40 CFR 52.07 - Control strategies.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Control strategies. 52.07 Section 52.07... PROMULGATION OF IMPLEMENTATION PLANS General Provisions § 52.07 Control strategies. (a) Each subpart specifies in what respects the control strategies are approved or disapproved. Where emission limitations...

  20. 40 CFR 52.07 - Control strategies.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Control strategies. 52.07 Section 52.07... PROMULGATION OF IMPLEMENTATION PLANS General Provisions § 52.07 Control strategies. (a) Each subpart specifies in what respects the control strategies are approved or disapproved. Where emission limitations...

  1. 40 CFR 52.07 - Control strategies.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategies. 52.07 Section 52.07... PROMULGATION OF IMPLEMENTATION PLANS General Provisions § 52.07 Control strategies. (a) Each subpart specifies in what respects the control strategies are approved or disapproved. Where emission limitations...

  2. Intermittent locomotion as an optimal control strategy

    PubMed Central

    Paoletti, P.; Mahadevan, L.

    2014-01-01

    Birds, fish and other animals routinely use unsteady effects to save energy by alternating between phases of active propulsion and passive coasting. Here, we construct a minimal model for such behaviour that can be couched as an optimal control problem via an analogy to travelling with a rechargeable battery. An analytical solution of the optimal control problem proves that intermittent locomotion has lower energy requirements relative to steady-state strategies. Additional realistic hypotheses, such as the assumption that metabolic cost at a given power should be minimal (the fixed gear hypothesis), a nonlinear dependence of the energy storage rate on propulsion and/or a preferred average speed, allow us to generalize the model and demonstrate the flexibility of intermittent locomotion with implications for biological and artificial systems. PMID:24711718

  3. Mixed-Strategy Chance Constrained Optimal Control

    NASA Technical Reports Server (NTRS)

    Ono, Masahiro; Kuwata, Yoshiaki; Balaram, J.

    2013-01-01

    This paper presents a novel chance constrained optimal control (CCOC) algorithm that chooses a control action probabilistically. A CCOC problem is to find a control input that minimizes the expected cost while guaranteeing that the probability of violating a set of constraints is below a user-specified threshold. We show that a probabilistic control approach, which we refer to as a mixed control strategy, enables us to obtain a cost that is better than what deterministic control strategies can achieve when the CCOC problem is nonconvex. The resulting mixed-strategy CCOC problem turns out to be a convexification of the original nonconvex CCOC problem. Furthermore, we also show that a mixed control strategy only needs to "mix" up to two deterministic control actions in order to achieve optimality. Building upon an iterative dual optimization, the proposed algorithm quickly converges to the optimal mixed control strategy with a user-specified tolerance.

  4. (New process modeling, design and control strategies for energy efficiency, high product quality and improved productivity in the process industries)

    SciTech Connect

    Not Available

    1991-01-01

    Highlights are reported of work to date on: resilient design and control of chemical reactors (polymerization, packed bed), operation of complex processing systems (compensators for multivariable systems with delays and Right Half Plane zeroes, process identification and controller design for multivariable systems, nonlinear systems control, distributed parameter systems), and computer-aided design software (CONSYD, POLYRED, expert systems). 15 figs, 54 refs. (DLC)

  5. [New process modeling, design and control strategies for energy efficiency, high product quality and improved productivity in the process industries

    SciTech Connect

    Not Available

    1991-12-31

    Highlights are reported of work to date on: resilient design and control of chemical reactors (polymerization, packed bed), operation of complex processing systems (compensators for multivariable systems with delays and Right Half Plane zeroes, process identification and controller design for multivariable systems, nonlinear systems control, distributed parameter systems), and computer-aided design software (CONSYD, POLYRED, expert systems). 15 figs, 54 refs. (DLC)

  6. Strategies and Decision Support Systems for Integrating Variable Energy Resources in Control Centers for Reliable Grid Operations

    SciTech Connect

    Jones, Lawrence E.

    2012-01-05

    A variety of studies have recently evaluated the opportunities for the large-scale integration of wind energy into the US power system. These studies have included, but are not limited to, "20 Percent Wind Energy by 2030: Increasing Wind Energy's Contribution to US Electricity Supply", the "Western Wind and Solar Integration Study", and the "Eastern Wind Integration and Transmission Study." Each of these US based studies have evaluated a variety of activities that can be undertaken by utilities to help integrate wind energy.

  7. Energy strategy: Roadmap to consensus

    SciTech Connect

    Not Available

    1990-11-01

    The United States lacks a comprehensive approach to policy-making in the energy realm. Today, as in the past, individual constituency groups tend to focus on their particular aspect of the energy challenge. Many employ a ``decide-announce-defend`` approach to policy-making, setting out to secure a unilateral advantage for themselves. By so doing, they inevitably pit interest against interest. The result is a polarization of constituencies, and shortsighted policies designed to address the issue of the moment. The American Energy Assurance Council (AEAC) is a non-profit organization founded in 1987 for the sole purpose of facilitating progress toward a fair efficient wise, stable, and consensus-based national energy strategy. AEAC does not have a substantive policy agencies. Rather, we are committed to supporting a process whereby the many stakeholders and policy makers concerned with energy-related issues can come together in productive discourse, thereby overcoming ignorance of each other`s positions. The Council seeks to act as a facilitative body, providing a ``safe`` context for inventive and creative thinking. We attempt to build a store of common knowledge, and to build on that store according to mutually agreed-upon groundrules, and employing sophisticated approaches to facilitation and mediation. This report, the National Energy Consensus Experiment (NECE), was an ambitious experiment in consensus-building. We learned a great deal from it, both in terms of substance and process, and we are convinced that it holds important lessons for others who may seek to build consensus in the public policy realm.

  8. Energy strategy: Roadmap to consensus

    SciTech Connect

    Not Available

    1990-11-01

    The United States lacks a comprehensive approach to policy-making in the energy realm. Today, as in the past, individual constituency groups tend to focus on their particular aspect of the energy challenge. Many employ a decide-announce-defend'' approach to policy-making, setting out to secure a unilateral advantage for themselves. By so doing, they inevitably pit interest against interest. The result is a polarization of constituencies, and shortsighted policies designed to address the issue of the moment. The American Energy Assurance Council (AEAC) is a non-profit organization founded in 1987 for the sole purpose of facilitating progress toward a fair efficient wise, stable, and consensus-based national energy strategy. AEAC does not have a substantive policy agencies. Rather, we are committed to supporting a process whereby the many stakeholders and policy makers concerned with energy-related issues can come together in productive discourse, thereby overcoming ignorance of each other's positions. The Council seeks to act as a facilitative body, providing a safe'' context for inventive and creative thinking. We attempt to build a store of common knowledge, and to build on that store according to mutually agreed-upon groundrules, and employing sophisticated approaches to facilitation and mediation. This report, the National Energy Consensus Experiment (NECE), was an ambitious experiment in consensus-building. We learned a great deal from it, both in terms of substance and process, and we are convinced that it holds important lessons for others who may seek to build consensus in the public policy realm.

  9. 2011 National Drug Control Strategy. Executive Summary

    ERIC Educational Resources Information Center

    Office of National Drug Control Policy, 2011

    2011-01-01

    In May of 2010, President Obama released the Administration's inaugural "National Drug Control Strategy", a comprehensive approach to combat the public health and safety consequences posed by drug use. Now, a year later, the Administration is releasing its update building upon that initial "Strategy". The "Strategy" establishes ambitious goals to…

  10. Alternative Strategies for Control of Sulfur Dioxide Emissions

    ERIC Educational Resources Information Center

    MacDonald, Bryce I.

    1975-01-01

    Achievement of air quality goals requires careful consideration of alternative control strategies in view of national concerns with energy and the economy. Three strategies which might be used by coal fired steam electric plants to achieve ambient air quality standards for sulfur dioxide have been compared and the analysis presented. (Author/BT)

  11. High-Energy-Density Fuel Blending Strategies and Drop Dispersion for Fuel Cost Reduction and Soot Propensity Control

    NASA Technical Reports Server (NTRS)

    Bellan, J.; Harstad, K.

    1998-01-01

    The idea that low soot propensity of high-energy-density (HED) liquid sooting fuels and cost reduction of a multicomponent energetic fuel can be achieved by doping a less expensive, less sooting liquid fuel with HED is tested through numerical simulations.

  12. National Drug Control Strategy. 2008 Annual Report

    ERIC Educational Resources Information Center

    Office of National Drug Control Policy, 2008

    2008-01-01

    This report presents the 2008 National Drug Control Strategy of the White House Office of National Drug Control Policy. The overarching goal of the President's Strategy is to reduce drug use in America through a balanced approach that focuses on stopping use before it starts, healing America's drug users, and disrupting the market for illegal…

  13. Energy Control Systems: Energy Savings.

    ERIC Educational Resources Information Center

    School Business Affairs, 1980

    1980-01-01

    The installation of proper control systems is estimated as saving up to 25 percent of the energy used in schools. Other potential energy-saving areas are transmission (heat loss or gain through walls, especially ceilings); internal load (heat from students, lights, and machinery); ventilation; and equipment maintenance. (Author/MLF)

  14. Optimal control of anthracnose using mixed strategies.

    PubMed

    Fotsa Mbogne, David Jaures; Thron, Christopher

    2015-11-01

    In this paper we propose and study a spatial diffusion model for the control of anthracnose disease in a bounded domain. The model is a generalization of the one previously developed in [15]. We use the model to simulate two different types of control strategies against anthracnose disease. Strategies that employ chemical fungicides are modeled using a continuous control function; while strategies that rely on cultivational practices (such as pruning and removal of mummified fruits) are modeled with a control function which is discrete in time (though not in space). For comparative purposes, we perform our analyses for a spatially-averaged model as well as the space-dependent diffusion model. Under weak smoothness conditions on parameters we demonstrate the well-posedness of both models by verifying existence and uniqueness of the solution for the growth inhibition rate for given initial conditions. We also show that the set [0, 1] is positively invariant. We first study control by impulsive strategies, then analyze the simultaneous use of mixed continuous and pulse strategies. In each case we specify a cost functional to be minimized, and we demonstrate the existence of optimal control strategies. In the case of pulse-only strategies, we provide explicit algorithms for finding the optimal control strategies for both the spatially-averaged model and the space-dependent model. We verify the algorithms for both models via simulation, and discuss properties of the optimal solutions. PMID:26407644

  15. Control Strategy for Echinococcus multilocularis

    PubMed Central

    Deplazes, Peter

    2008-01-01

    Echinococcus multilocularis, the causative agent of zoonotic alveolar echinococcosis, can be controlled effectively by the experimental delivery of anthelminthic baits for urban foxes. Monthly baiting over a 45-month period was effective for long-lasting control. Trimonthly baiting intervals were far less effective and did not prevent parasite recovery. PMID:18826831

  16. Control strategy for Echinococcus multilocularis.

    PubMed

    Hegglin, Daniel; Deplazes, Peter

    2008-10-01

    Echinococcus multilocularis, the causative agent of zoonotic alveolar echinococcosis, can be controlled effectively by the experimental delivery of anthelminthic baits for urban foxes. Monthly baiting over a 45-month period was effective for long-lasting control. Trimonthly baiting intervals were far less effective and did not prevent parasite recovery. PMID:18826831

  17. White House Presses New Energy Strategy

    ERIC Educational Resources Information Center

    Science, 1975

    1975-01-01

    Outlines the energy strategy of the Democrats and details the energy proposals of the Ford Administration. The Administration plan involves a complex system of taxes and tariffs and a proposed Synthetic Fuels Commercialization Program. (GS)

  18. Transportation energy strategy: Project {number_sign}5 of the Hawaii Energy Strategy Development Program

    SciTech Connect

    1995-08-01

    This study was prepared for the State Department of Business, Economic Development and Tourism (DBEDT) as part of the Hawaii Energy Strategy program. Authority and responsibility for energy planning activities, such as the Hawaii Energy Strategy, rests with the State Energy Resources Coordinator, who is the Director of DBEDT. Hawaii Energy Strategy Study No. 5, Transportation Energy Strategy Development, was prepared to: collect and synthesize information on the present and future use of energy in Hawaii`s transportation sector, examine the potential of energy conservation to affect future energy demand; analyze the possibility of satisfying a portion of the state`s future transportation energy demand through alternative fuels; and recommend a program targeting energy use in the state`s transportation sector to help achieve state goals. The analyses and conclusions of this report should be assessed in relation to the other Hawaii Energy Strategy Studies in developing a comprehensive state energy program. 56 figs., 87 tabs.

  19. Meningococcal meningitis outbreak control strategies.

    PubMed

    Ahlawat, S; Kumar, R; Roy, P; Varma, S; Sharma, B K

    2000-12-01

    Meningococcal meningitis has been occurring worldwide in both endemic and epidemic forms. Serogroup A accounts for majority of cases of epidemic as well as endemic Meningococcal meningitis in developing nations, whereas group C and group B causes epidemic and endemic meningococcal meningitis in developed countries. Person to person spread of N. meningitides generally occurs through inhalation of droplets of infected nasopharyngeal secretions by direct or indirect oral contact. Incubation period varies from 2 to 10 days. N. meningitides typically causes acute infective illness characterized by sequential development of upper respiratory tract infection, meningococcemia, meningitis and focal neurological deficit. Over 90 per cent cases of adult meningococcal infections have cerebrospinal meningitis, whereas in children prevalence of meningitis is much lower (50 per cent). Acute meningitis manifests with fever, severe headache, vomiting and neck stiffness. Presentations may be non-specific in infants, elderly and in patients with fulminant meningococcemia. Diagnosis is confirmed with cerebrospinal fluid analysis. Overall mortality due to meningitis is usually around 10 per cent. In meningococcal septicemia, the case fatality rate may exceed 50 per cent. Preventive strategies include vaccination, chemoprophylaxis and early detection and treatment. Mass vaccination campaign, if appropriately carried out, has been documented to halt an epidemic of meningococcal disease due to serogroup A or C. In the present review we have discussed the available evidence with regards to prevention at primary, secondary and tertiary level. Public health approach to an outbreak of meningococcal meningitis in a community or an organization is also outlined. PMID:11668937

  20. Adaptive Control Strategies for Flexible Robotic Arm

    NASA Technical Reports Server (NTRS)

    Bialasiewicz, Jan T.

    1996-01-01

    The control problem of a flexible robotic arm has been investigated. The control strategies that have been developed have a wide application in approaching the general control problem of flexible space structures. The following control strategies have been developed and evaluated: neural self-tuning control algorithm, neural-network-based fuzzy logic control algorithm, and adaptive pole assignment algorithm. All of the above algorithms have been tested through computer simulation. In addition, the hardware implementation of a computer control system that controls the tip position of a flexible arm clamped on a rigid hub mounted directly on the vertical shaft of a dc motor, has been developed. An adaptive pole assignment algorithm has been applied to suppress vibrations of the described physical model of flexible robotic arm and has been successfully tested using this testbed.

  1. HTGR Resilient Control System Strategy

    SciTech Connect

    Lynne M. Stevens

    2010-09-01

    A preeminent objective for corporate and government organizations is the protection of major investments, which is attained by achieving state awareness, a comprehensive understanding of security and safety, for critical infrastructures. Given the dependence of critical infrastructure on control systems for automation, the integrity of these systems and their ability to provide owner/operators a high degree of state awareness is essential in attaining a high degree of investment protection and public acceptance. Operators as well as government are therefore burdened to ensure they have a timely understanding of the status of their plant or all plants, respectively, to ensure efficient operations and investment and public protection. “This characterization is a significant objective that must consider many aspects of instrumentation, control, and intelligent systems in order to achieve the required result. These aspects include sensory, communication, analysis, decision, and human system interfaces necessary to achieve fusion of data and presentation of results that will provide an understanding of what issues are important and why.

  2. Household energy management strategies in Bulgaria's transitioning energy sector

    NASA Astrophysics Data System (ADS)

    Carper, Mark Daniel Lynn

    Recent transition literature of post-socialist states has addressed the shortcomings of a rapid blanket implementation of neo-liberal policies and practices placed upon a landscape barren of the needed institutions and experiences. Included in these observations are the policy-making oversight of spatial socioeconomic variations and their individual and diverse methods of coping with their individual challenges. Of such literature addressing the case of Bulgaria, a good portion deals with the spatial consequences of restructuring as well as with embedded disputes over access to and control of resources. With few exceptions, studies of Bulgaria's changing energy sector have largely been at the state level and have not been placed within the context of spatial disparities of socioeconomic response. By exploring the variations of household energy management strategies across space, my dissertation places this resource within such a theoretical context and offers analysis based on respective levels of economic and human development, inherited material infrastructures, the organization and activities of institutions, and fuel and technological availability. A closed survey was distributed to explore six investigational themes across four geographic realms. The investigational themes include materials of housing construction, methods of household heating, use of electrical appliances, energy conservation strategies, awareness and use of energy conservation technologies, and attitudes toward the transitioning energy sector. The geographic realms include countrywide results, the urban-rural divide, regional variations, and urban divisions of the capital city, Sofia. Results conclude that, indeed, energy management strategies at the household level have been shaped by multiple variables, many of which differ across space. These variables include price sensitivity, degree of dependence on remnant technologies, fuel and substitute availability, and level of human and

  3. Dispatch Strategy Development for Grid-tied Household Energy Systems

    NASA Astrophysics Data System (ADS)

    Cardwell, Joseph

    The prevalence of renewable generation will increase in the next several decades and offset conventional generation more and more. Yet this increase is not coming without challenges. Solar, wind, and even some water resources are intermittent and unpredictable, and thereby create scheduling challenges due to their inherent "uncontrolled" nature. To effectively manage these distributed renewable assets, new control algorithms must be developed for applications including energy management, bridge power, and system stability. This can be completed through a centralized control center though efforts are being made to parallel the control architecture with the organization of the renewable assets themselves--namely, distributed controls. Building energy management systems are being employed to control localized energy generation, storage, and use to reduce disruption on the net utility load. One such example is VOLTTRONTM, an agent-based platform for building energy control in real time. In this thesis, algorithms developed in VOLTTRON simulate a home energy management system that consists of a solar PV array, a lithium-ion battery bank, and the grid. Dispatch strategies are implemented to reduce energy charges from overall consumption (/kWh) and demand charges (/kW). Dispatch strategies for implementing storage devices are tuned on a month-to-month basis to provide a meaningful economic advantage under simulated scenarios to explore algorithm sensitivity to changing external factors. VOLTTRON agents provide automated real-time optimization of dispatch strategies to efficiently manage energy supply and demand, lower consumer costs associated with energy usage, and reduce load on the utility grid.

  4. A new control strategy of SMES for mitigating subsynchronous oscillations

    NASA Astrophysics Data System (ADS)

    Farahani, Mohsen

    2012-12-01

    This paper proposes a new strategy to mitigate the subsynchronous oscillations in power systems compensated by series capacitors via control of active power of superconducting magnetic energy storage (SMES) unit. The strategy is based on the generator acceleration signal. So, the SMES absorbs or generates the energy imbalance caused by different disturbances in the power system and suppresses the subsynchronous oscillations. The chaotic optimization algorithm (COA) is used to achieve the optimal parameter of the proposed controller. To validate the capability of the SMES in damping oscillations, some simulations with different disturbances are performed on the first model of IEEE second benchmark model. All the simulation results show that the subsynchronous resonance as well as low frequency oscillation (LFO) is satisfactorily mitigated by the SMES controlled by the proposed strategy.

  5. Low Activity Waste Feed Process Control Strategy

    SciTech Connect

    STAEHR, T.W.

    2000-06-14

    The primary purpose of this document is to describe the overall process control strategy for monitoring and controlling the functions associated with the Phase 1B high-level waste feed delivery. This document provides the basis for process monitoring and control functions and requirements needed throughput the double-shell tank system during Phase 1 high-level waste feed delivery. This document is intended to be used by (1) the developers of the future Process Control Plan and (2) the developers of the monitoring and control system.

  6. Control of DC Motor Using Different Control Strategies

    NASA Astrophysics Data System (ADS)

    Alasooly, Hedaya; Redha, Mohammed

    2010-06-01

    A simple model of a DC motor driving an inertial load has the angular rate of the load, ω, as the output and applied voltage, νapp, as the input. The ultimate goal of this paper is to control the angular rate by varying the applied voltage using different control strategies for comparison purpose. The comparision is made between the proptional controller, integral controller, propotional and integral controller, phase lag compensator, derivitive controller, lead integral compensator, lead lag compensator, PID controller and the the linear quadratic tracker design based on the optimal control theory.

  7. Hawaii Energy Strategy program. Annual report 1993

    SciTech Connect

    Not Available

    1993-12-31

    This is the second annual report on the Hawaii Energy Strategy (HES) program which began on March 2, 1992, under a Cooperative Agreement (FCO3-92F19l68) with the United States Department of Energy (USDOE). The HES program is scheduled for completion by December 31, 1994. As outlined in the Statement of Joint Objectives. The purpose of the study is to develop an integrated State of Hawaii energy strategy, including an assessment of the State`s fossil fuel reserve requirements and the most effective way to meet those needs, the availability and practicality of increasing the use of native energy resources, potential alternative fossil energy technologies such as coal gasification and potential energy efficiency measures which could lead to demand reduction. This work contributes to the (US)DOE mission, will reduce the State`s vulnerability to energy supply disruptions and contributes to the public good.

  8. Hawaii Energy Strategy program. [First Annual Report

    SciTech Connect

    Not Available

    1992-01-01

    The Hawaii Energy Strategy (HES) program began on March 2, 1992, under United States Department of Energy Cooperative Agreement DE-FC03-92F19168, and is scheduled for completion by December 31, 1994. As outlined in the Statement of Joint Objectives: The purpose of the study is to develop an integrated State of Hawaii energy strategy, including an assessment of the State's fossil fuel reserve requirements and the most effective way to meet those needs, the availability and practicality of increasing the use of native energy resources, potential alternative fossil energy technologies such as coal gasification and potential energy efficiency measures which could lead to demand reduction. This work contributes to the DOE mission, will reduce the State's vulnerability to energy supply disruptions and contributes to the public good.

  9. Hawaii Energy Strategy program. Annual report, 1992

    SciTech Connect

    Not Available

    1992-12-31

    The Hawaii Energy Strategy (HES) program began on March 2, 1992, under United States Department of Energy Cooperative Agreement DE-FC03-92F19168, and is scheduled for completion by December 31, 1994. As outlined in the Statement of Joint Objectives: The purpose of the study is to develop an integrated State of Hawaii energy strategy, including an assessment of the State`s fossil fuel reserve requirements and the most effective way to meet those needs, the availability and practicality of increasing the use of native energy resources, potential alternative fossil energy technologies such as coal gasification and potential energy efficiency measures which could lead to demand reduction. This work contributes to the DOE mission, will reduce the State`s vulnerability to energy supply disruptions and contributes to the public good.

  10. Energy strategy on five continents

    SciTech Connect

    Lee, B.S.; Sen, C.T.

    1981-01-01

    Energy programs in Japan, New Zealand, Brazil, South Africa, and Federal Republic of Germany are examined. All abandoned their previous energy policies following the initial oil shock of 1973 by immediately putting in place programs designed to reduce dependence on oil imports by developing domestic resources, diversifying sources of supply, and conserving energy - programs that were expanded following the second oil shock of 1979. Their governments took the lead in formulating overall national policy, while industry implemented the programs with varying degrees of government participation and financial support. Short-term economics were not the prime consideration in developing these programs, for the use of indigenous resources is not necessarily cheaper than imported oil on a strictly per-barrel basis. But these countries have been willing to pay a premium that takes into account the very-real, though perhaps less-obvious, long-term effects of reduced reliance on imports: a slowdown in inflation; more jobs for citizens; freedom from the vicissitudes of geopolitics; and increased security of supply - the so-called externalities. The importance these countries assign to their efforts toward energy self-reliance is evident from the size of their expenditures.

  11. Advanced control strategies for fluidized bed dryers

    SciTech Connect

    Siettos, C.I.; Kiranoudis, C.T.; Bafas, G.V.

    1999-11-01

    Generating the best possible control strategy comprises a necessity for industrial processes, by virtue of product quality, cost reduction and design simplicity. Three different control approaches, namely an Input-Output linearizing, a fuzzy logic and a PID controller, are evaluated for the control of a fluidized bed dryer, a typical non-linear drying process of wide applicability. Based on several closed loop characteristics such as settling times, maximum overshoots and dynamic performance criteria such as IAE, ISE and ITAE, it is shown that the Input-Output linearizing and the fuzzy logic controller exhibit a better performance compared to the PID controller tuned optimally with respect to IAE, for a wide range of disturbances; yet, the relevant advantage of the fuzzy logic over the conventional nonlinear controller issues upon its design simplicity. Typical load rejection and set-point tracking examples are given to illustrate the effectiveness of the proposed approach.

  12. A perfect match: Nuclear energy and the National Energy Strategy

    SciTech Connect

    Not Available

    1990-11-01

    In the course of developing the National Energy Strategy, the Department of Energy held 15 public hearings, heard from more than 375 witnesses and received more than 1000 written comments. In April 1990, the Department published an Interim Report on the National Energy Strategy, which compiles those public comments. The National Energy Strategy must be based on actual experience and factual analysis of our energy, economic and environmental situation. This report by the Nuclear Power Oversight committee, which represents electric utilities and other organizations involved in supplying electricity from nuclear energy to the American people, provides such an analysis. The conclusions here are based on hard facts and actual worldwide experience. This analysis of all the available data supports -- indeed, dictates -- expanded reliance on nuclear energy in this nation's energy supply to achieve the President's goals. 33 figs.

  13. A Pollution Control Strategy Game: Costs of Control Policies.

    ERIC Educational Resources Information Center

    Bierma, Thomas J.; Walbert, Mark S.

    1987-01-01

    Describes an interactive classroom game designed to enhance student understanding of air pollution control strategies. Discusses the game's focus on the differences in compliance costs that can occur between the three principal control approaches of emission limits, emission permits, and emission taxes. (TW)

  14. Situational Strategies for Self-Control.

    PubMed

    Duckworth, Angela L; Gendler, Tamar Szabó; Gross, James J

    2016-01-01

    Exercising self-control is often difficult, whether declining a drink in order to drive home safely, passing on the chocolate cake to stay on a diet, or ignoring text messages to finish reading an important paper. But enacting self-control is not always difficult, particularly when it takes the form of proactively choosing or changing situations in ways that weaken undesirable impulses or potentiate desirable ones. Examples of situational self-control include the partygoer who chooses a seat far from where drinks are being poured, the dieter who asks the waiter not to bring around the dessert cart, and the student who goes to the library without a cell phone. Using the process model of self-control, we argue that the full range of self-control strategies can be organized by considering the timeline of the developing tempting impulse. Because impulses tend to grow stronger over time, situational self-control strategies-which can nip a tempting impulse in the bud-may be especially effective in preventing undesirable action. Ironically, we may underappreciate situational self-control for the same reason it is so effective-namely, that by manipulating our circumstances to advantage, we are often able to minimize the in-the-moment experience of intrapsychic struggle typically associated with exercising self-control. PMID:26817725

  15. Optimal charge control strategies for stationary photovoltaic battery systems

    NASA Astrophysics Data System (ADS)

    Li, Jiahao; Danzer, Michael A.

    2014-07-01

    Battery systems coupled to photovoltaic (PV) modules for example fulfill one major function: they locally decouple PV generation and consumption of electrical power leading to two major effects. First, they reduce the grid load, especially at peak times and therewith reduce the necessity of a network expansion. And second, they increase the self-consumption in households and therewith help to reduce energy expenses. For the management of PV batteries charge control strategies need to be developed to reach the goals of both the distribution system operators and the local power producer. In this work optimal control strategies regarding various optimization goals are developed on the basis of the predicted household loads and PV generation profiles using the method of dynamic programming. The resulting charge curves are compared and essential differences discussed. Finally, a multi-objective optimization shows that charge control strategies can be derived that take all optimization goals into account.

  16. Vertical axis wind turbine control strategy

    SciTech Connect

    McNerney, G.M.

    1981-08-01

    Early expensive in automatic operation of the Sandia 17-m vertical axis research wind turbine (VAWT) has demonstrated the need for a systematic study of control algorithms. To this end, a computer model has been developed that uses actual wind time series and turbine performance data to calculate the power produced by the Sandia 17-m VAWT operating in automatic control. The model has been used to investigate the influence of starting algorithms on annual energy production. The results indicate that, depending on turbine and local wind characteristics, a bad choice of a control algorithm can significantly reduce overall energy production. The model can be used to select control algorithms and threshold parameters that maximize long-term energy production. An attempt has been made to generalize these results from local site and turbine characteristics to obtain general guidelines for control algorithm design.

  17. Analysis of alternative strategies for energy conservation in new buildings

    SciTech Connect

    Fang, J.M.; Tawil, J.J.

    1980-12-01

    Building Energy Performance Standards (BEPS) were mandated by the Energy Conservation Standards for New Buildings Act of 1976 (Title III of Energy Conservation and Production Act) to promote energy efficiency and the use of renewable resources in new buildings. The report analyzes alternative Federal strategies and their component policy instruments and recommends a strategy for achieving the goals of the Act. The concern is limited to space conditioning (heating, cooling, and lighting) and water heating. The policy instruments considered include greater reliance on market forces; research and development; information, education and demonstration programs; tax incentives and sanctions; mortgage and finance programs; and regulations and standards. The analysis starts with an explanation of the barriers to energy conservation in the residential and commercial sectors. Individual policy instruments are then described and evaluated with respect to energy conservation, economic efficiency, equity, political impacts, and implementation and other transitional impacts. Five possible strategies are identified: (1) increased reliance on the market place; (2) energy consumption tax and supply subsidies; (3) BEPS with no sanctions and no incentives; (4) BEPS with sanctions and incentives (price control); and (5) BEPS with sanctions and incentives (no price controls). A comparative analysis is performed. Elements are proposed for inclusion in a comprehensive strategy for conservation in new buildings. (MCW)

  18. Cigarette smoking: health effects and control strategies.

    PubMed

    Alberg, Anthony J

    2008-12-01

    Active cigarette smoking causes a broad spectrum of diseases that extend to many different organ systems. Its numerous deleterious health effects, combined with the substantial prevalence of cigarette smoking, make it a major worldwide cause of death. Smoking contributes so heavily to the mortality burden because it is a major cause of vascular disease, cancer and chronic obstructive pulmonary disease. In addition to these diseases, cigarette smoking also causes other respiratory symptoms, adversely affects reproductive outcomes and is a cause of diminished health status. Furthermore, exposure to secondhand smoke is an established cause of coronary heart disease and lung cancer, as well as a host of other adverse health effects. Given that cigarette smoking is such a major threat to global public health, controlling the worldwide epidemic of cigarette smoking would lead to enormous public health benefits. Strategies to control cigarette smoking at the societal level include smoke-free workplace legislation, increasing cigarette taxes and regulating cigarette advertising. On the individual level, preventing the initiation of cigarette smoking among youths is the optimal strategy; in practice, discovering efficacious primary prevention interventions has proven challenging. During the past two decades, major advances have been made in extending the menu of options available to assist dependent smokers in successfully quitting smoking. Successfully combating cigarette smoking requires a broad-based commitment to smoking control from multiple stakeholders, along with a multifaceted strategy that addresses both societal and individual factors. PMID:19198699

  19. Analysis of alternative strategies for energy conservation in new buildings

    NASA Astrophysics Data System (ADS)

    Fang, J. M.; Tawil, J.

    1980-12-01

    The policy instruments considered include: greater reliance on market forces; research and development; information, education and demonstration programs; tax incentives and sanctions; mortgage and finance programs; and regulations and standards. The analysis starts with an explanation of the barriers to energy conservation in the residential and commercial sectors. Individual policy instruments are described and evaluated with respect to energy conservation, economic efficiency, equity, political impacts, and implementation and other transitional impacts. Five possible strategies are identified: (1) increased reliance on the market place; (2) energy consumption tax and supply subsidies; (3) Building Energy Performance Standards (BEPS) with no sanctions and no incentives; (4) BEPS with sanctions and incentives (price control); and (5) BEPS with sanctions and incentives (no price controls). A comparative analysis is performed. Elements are proposed for inclusion in a comprehensive strategy for conservation in new buildings.

  20. Automated Demand Response Strategies and Commissioning CommercialBuilding Controls

    SciTech Connect

    Piette, Mary Ann; Watson, David; Motegi, Naoya; Kiliccote, Sila; Linkugel, Eric

    2006-05-01

    California electric utilities have been exploring the use of dynamic critical peak pricing (CPP) and other demand response programs to help reduce peaks in customer electric loads. CPP is a new electricity tariff design to promote demand response. This paper begins with a brief review of terminology regarding energy management and demand response, followed by a discussion of DR control strategies and a preliminary overview of a forthcoming guide on DR strategies. The final section discusses experience to date with these strategies, followed by a discussion of the peak electric demand savings from the 2005 Automated CPP program. An important concept identified in the automated DR field tests is that automated DR will be most successful if the building commissioning industry improves the operational effectiveness of building controls. Critical peak pricing and even real time pricing are important trends in electricity pricing that will require new functional tests for building commissioning.

  1. NSIDC Data Center: Energy Reduction Strategies

    SciTech Connect

    2012-05-01

    The Green Data Center Project was a successful effort to significantly reduce the energy use of the National Snow and Ice Data Center (NSIDC). Through a full retrofit of a traditional air conditioning system, the cooling energy required to meet the data center’s constant load has been reduced by over 70% for summer months and over 90% for cooler winter months. This significant reduction is achievable through the use of airside economization and a new indirect evaporative cooling cycle. One of the goals of this project was to create awareness of simple and effective energy reduction strategies for data centers. Although this particular project was able to maximize the positive effects of airside economization and indirect evaporative cooling because of its geographic location, similar strategies may also be relevant for many other sites and data centers in the United States.

  2. Guidance and control strategies for aerospace vehicles

    NASA Technical Reports Server (NTRS)

    Hibey, Joseph L.; Naidu, Desineni S.

    1990-01-01

    The first part of the report concerns broadly the summary of the work done in the areas of singular perturbations and time scales (SPaTS), aerobraking technology, guidance and aerocruise. The synergistic plane change problem connected with orbital transfer employing aeroassist technology, is addressed. The mission involves transfer from high Earth orbit to low Earth orbit with plane change being performed within the atmosphere. The complete mission consists of a deorbit phase, atmospheric phase, and finally reorbit phase. The atmospheric maneuver is composed of an entry mode, a cruise mode, and finally an exit mode. During the cruise mode, constant altitude and velocity are maintained by means of bank angle control with constant thrust or thrust control with constant bank angle. Comparisons between these two control strategies bring out some interesting features.

  3. Combining sustainable energy development and employment strategies

    SciTech Connect

    Olesen, G.B.

    1994-12-31

    International Network for Sustainable Energy--Europe (INforSE--Europe) is developing proposals to focus on the important connections between CO,-abatement strategies and employment. Basically, support for unemployed people in industrialized countries can be used to support job-creating sustainable energy measures. This paper describes the first version of the proposals for the European Union (EU), covering estimates of potential employment effects of wind energy, solar thermal energy, combustible and digestible biomass, and increased energy efficiency in heat and electricity. The result of these first estimates is that these proposals can create directly about 600,000 jobs and by induced effects an additional 1,300,000 jobs lasting for more than 10 years. The proposed elements of a sustainable energy strategy will have a significant role in reducing the unemployment of 17 million persons in EU. Because of reduced expenses of the states for unemployment benefits and increased tax revenue, it is estimated that the states can support the implementation of the proposals with at least 25% of the investments and still have a positive effect on the state budgets, The paper also describes the worldwide INforSE campaign and a number of other NGO activities on environment, energy, and employment.

  4. Control strategies for planetary rover motion and manipulator control

    NASA Technical Reports Server (NTRS)

    Trautwein, W.

    1973-01-01

    An unusual insect-like vehicle designed for planetary surface exploration is made the occasion for a discussion of control concepts in path selection, hazard detection, obstacle negotiation, and soil sampling. A control scheme which actively articulates the pitching motion between a single-loop front module and a dual loop rear module leads to near optimal behavior in soft soil; at the same time the vehicle's front module acts as a reliable tactile forward probe with a detection range much longer than the stopping distance. Some optimal control strategies are discussed, and the photos of a working scale model are displayed.

  5. Active control strategy on a catenary-pantograph validated model

    NASA Astrophysics Data System (ADS)

    Sanchez-Rebollo, C.; Jimenez-Octavio, J. R.; Carnicero, A.

    2013-04-01

    Dynamic simulation methods have become essential in the design process and control of the catenary-pantograph system, overall since high-speed trains and interoperability criteria are getting very trendy. This paper presents an original hardware-in-the-loop (HIL) strategy aimed at integrating a multicriteria active control within the catenary-pantograph dynamic interaction. The relevance of HIL control systems applied in the frame of the pantograph is undoubtedly increasing due to the recent and more demanding requirements for high-speed railway systems. Since the loss of contact between the catenary and the pantograph leads to arcing and electrical wear, and too high contact forces cause mechanical wear of both the catenary wires and the strips of the pantograph, not only prescribed but also economic and performance criteria ratify such a relevance. Different configurations of the proportional-integral-derivative (PID) controller are proposed and applied to two different plant systems. Since this paper is mainly focused on the control strategy, both plant systems are simulation models though the methodology is suitable for a laboratory bench. The strategy of control involves a multicriteria optimisation of the contact force and the consumption of the energy supplied by the control force, a genetic algorithm has been applied for this purpose. Thus, the PID controller is fitted according to these conflicting objectives and tested within a nonlinear lumped model and a nonlinear finite element model, being the last one validated against the European Standard EN 50318. Finally, certain tests have been accomplished in order to analyse the robustness of the control strategy. Particularly, the relevance or the plant simulation, the running speed and the instrumentation time delay are studied in this paper.

  6. Genetic control of mosquitoes: population suppression strategies.

    PubMed

    Wilke, André Barretto Bruno; Marrelli, Mauro Toledo

    2012-01-01

    Over the last two decades, morbidity and mortality from malaria and dengue fever among other pathogens are an increasing Public Health problem. The increase in the geographic distribution of vectors is accompanied by the emergence of viruses and diseases in new areas. There are insufficient specific therapeutic drugs available and there are no reliable vaccines for malaria or dengue, although some progress has been achieved, there is still a long way between its development and actual field use. Most mosquito control measures have failed to achieve their goals, mostly because of the mosquito's great reproductive capacity and genomic flexibility. Chemical control is increasingly restricted due to potential human toxicity, mortality in no target organisms, insecticide resistance, and other environmental impacts. Other strategies for mosquito control are desperately needed. The Sterile Insect Technique (SIT) is a species-specific and environmentally benign method for insect population suppression, it is based on mass rearing, radiation mediated sterilization, and release of a large number of male insects. Releasing of Insects carrying a dominant lethal gene (RIDL) offers a solution to many of the drawbacks of traditional SIT that have limited its application in mosquitoes while maintaining its environmentally friendly and species-specific utility. The self-limiting nature of sterile mosquitoes tends to make the issues related to field use of these somewhat less challenging than for self-spreading systems characteristic of population replacement strategies. They also are closer to field use, so might be appropriate to consider first. The prospect of genetic control methods against mosquito vectored human diseases is rapidly becoming a reality, many decisions will need to be made on a national, regional and international level regarding the biosafety, social, cultural and ethical aspects of the use and deployment of these vector control methods. PMID:22983293

  7. Hawaii Energy Strategy: Program guide. [Contains special sections on analytical energy forecasting, renewable energy resource assessment, demand-side energy management, energy vulnerability assessment, and energy strategy integration

    SciTech Connect

    Not Available

    1992-09-01

    The Hawaii Energy Strategy program, or HES, is a set of seven projects which will produce an integrated energy strategy for the State of Hawaii. It will include a comprehensive energy vulnerability assessment with recommended courses of action to decrease Hawaii's energy vulnerability and to better prepare for an effective response to any energy emergency or supply disruption. The seven projects are designed to increase understanding of Hawaii's energy situation and to produce recommendations to achieve the State energy objectives of: Dependable, efficient, and economical state-wide energy systems capable of supporting the needs of the people, and increased energy self-sufficiency. The seven projects under the Hawaii Energy Strategy program include: Project 1: Develop Analytical Energy Forecasting Model for the State of Hawaii. Project 2: Fossil Energy Review and Analysis. Project 3: Renewable Energy Resource Assessment and Development Program. Project 4: Demand-Side Management Program. Project 5: Transportation Energy Strategy. Project 6: Energy Vulnerability Assessment Report and Contingency Planning. Project 7: Energy Strategy Integration and Evaluation System.

  8. A personal history: Technology to energy strategy

    SciTech Connect

    Starr, C.

    1995-11-01

    This personal history spans a half century of participation in the frontiers of applies science and engineering ranging from the nuclear weapons project of World War II, through the development of nuclear power, engineering education, and risk analysis, to today`s energy research and development. In each of these areas, this account describes some of the exciting opportunities for technology to contribute to society`s welfare, as well as the difficulties and constraints imposed by society`s institutional and political systems. The recounting of these experiences in energy research and development illustrates the importance of embracing social values, cultures, and environmental views into the technologic design of energy options. The global importance of energy in a rapidly changing and unpredictable world suggests a strategy for the future based on these experiences which emphasizes the value of applied research and development on a full spectrum of potential options.

  9. Does energy availability predict gastropod reproductive strategies?

    PubMed Central

    McClain, Craig R.; Filler, Ryan; Auld, Josh R.

    2014-01-01

    The diversity of reproductive strategies in nature is shaped by a plethora of factors including energy availability. For example, both low temperatures and limited food availability could increase larval exposure to predation by slowing development, selecting against pelagic and/or feeding larvae. The frequency of hermaphroditism could increase under low food availability as population density (and hence mate availability) decreases. We examine the relationship between reproductive/life-history traits and energy availability for 189 marine gastropod families. Only larval type was related to energy availability with the odds of having planktotrophic larvae versus direct development decreasing by 1% with every one-unit increase in the square root of carbon flux. Simultaneous hermaphroditism also potentially increases with carbon flux, but this effect disappears when accounting for evolutionary relationships among taxa. Our findings are in contrast to some theory and empirical work demonstrating that hermaphroditism should increase and planktotrophic development should decrease with decreasing productivity. Instead, they suggest that some reproductive strategies are too energetically expensive at low food availabilities, or arise only when energy is available, and others serve to capitalize on opportunities for aggregation or increased energy availability. PMID:25009058

  10. Does energy availability predict gastropod reproductive strategies?

    PubMed

    McClain, Craig R; Filler, Ryan; Auld, Josh R

    2014-08-22

    The diversity of reproductive strategies in nature is shaped by a plethora of factors including energy availability. For example, both low temperatures and limited food availability could increase larval exposure to predation by slowing development, selecting against pelagic and/or feeding larvae. The frequency of hermaphroditism could increase under low food availability as population density (and hence mate availability) decreases. We examine the relationship between reproductive/life-history traits and energy availability for 189 marine gastropod families. Only larval type was related to energy availability with the odds of having planktotrophic larvae versus direct development decreasing by 1% with every one-unit increase in the square root of carbon flux. Simultaneous hermaphroditism also potentially increases with carbon flux, but this effect disappears when accounting for evolutionary relationships among taxa. Our findings are in contrast to some theory and empirical work demonstrating that hermaphroditism should increase and planktotrophic development should decrease with decreasing productivity. Instead, they suggest that some reproductive strategies are too energetically expensive at low food availabilities, or arise only when energy is available, and others serve to capitalize on opportunities for aggregation or increased energy availability. PMID:25009058

  11. 40 CFR 52.2584 - Control strategy; Particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy; Particulate matter... Control strategy; Particulate matter. (a) Part D—Disapproval—USEPA disapproves Regulation NR 154.11(7)(b... control strategy to attain and maintain the standards for particulate matter, because it does not...

  12. 40 CFR 52.2584 - Control strategy; Particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 5 2012-07-01 2012-07-01 false Control strategy; Particulate matter... Control strategy; Particulate matter. (a) Part D—Disapproval—USEPA disapproves Regulation NR 154.11(7)(b... control strategy to attain and maintain the standards for particulate matter, because it does not...

  13. 40 CFR 52.2584 - Control strategy; Particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 5 2014-07-01 2014-07-01 false Control strategy; Particulate matter... Control strategy; Particulate matter. (a) Part D—Disapproval—USEPA disapproves Regulation NR 154.11(7)(b... control strategy to attain and maintain the standards for particulate matter, because it does not...

  14. 40 CFR 52.2584 - Control strategy; Particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 5 2013-07-01 2013-07-01 false Control strategy; Particulate matter... Control strategy; Particulate matter. (a) Part D—Disapproval—USEPA disapproves Regulation NR 154.11(7)(b... control strategy to attain and maintain the standards for particulate matter, because it does not...

  15. 40 CFR 52.2584 - Control strategy; Particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy; Particulate matter... Control strategy; Particulate matter. (a) Part D—Disapproval—USEPA disapproves Regulation NR 154.11(7)(b... control strategy to attain and maintain the standards for particulate matter, because it does not...

  16. 40 CFR 52.728 Control strategy: Nitrogen dioxide. - [Reserved

    Code of Federal Regulations, 2014 CFR

    1998-07-01

    ... 40 Protection of Environment 3 1998-07-01 1998-07-01 false 52.728 Control strategy: Nitrogen dioxide. Section 52.728 Control strategy: Nitrogen dioxide. AIR PROGRAMS-(CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Illinois § 52.728Control strategy: Nitrogen dioxide....

  17. 40 CFR 52.728 Control strategy: Nitrogen dioxide. - [Reserved

    Code of Federal Regulations, 2010 CFR

    1997-07-01

    ... 40 Protection of Environment 3 1997-07-01 1997-07-01 false 52.728 Control strategy: Nitrogen dioxide. Section 52.728 Control strategy: Nitrogen dioxide. AIR PROGRAMS-(CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Illinois § 52.728Control strategy: Nitrogen dioxide....

  18. 40 CFR 52.728 Control strategy: Nitrogen dioxide. - [Reserved

    Code of Federal Regulations, 2013 CFR

    1996-07-01

    ... 40 Protection of Environment 2 1996-07-01 1996-07-01 false 52.728 Control strategy: Nitrogen dioxide. Section 52.728 Control strategy: Nitrogen dioxide. AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Illinois § 52.728Control strategy: Nitrogen dioxide....

  19. ACIS Thermal Control and Observing Strategies

    NASA Astrophysics Data System (ADS)

    Adams-Wolk, Nancy; Plucinsky, P. P.; Alcroft, T. L.; Germain, G.

    2011-09-01

    Nearing its 13th observing cycle, the Chandra X-Ray Observatory continues to deliver excellent science to the High Energy community. The orbit of Chandra, and thermal conditions of the spacecraft and instruments have changed over time which has necessitated changes in observing strategies; particularly for the ACIS instrument. This poster focuses on expected changes to be implemented in Cycle 13 for observing with the ACIS instrument. We will focus on the thermal issues with ACIS, including warming of the PSMC, DEA, and Focal Plane. We discuss the causes of the warming of these components of ACIS based on past data, and how this warming can affect observations. Trending studies have strongly suggested changes to the future observing strategies for ACIS. We discuss these changes which include reducing the number of CCDs powered on for temperature sensitive observations, implementing an ACIS FP temperature model to predict temperatures, and the use of optional CCDs to reduce the number of CCDs during the planning of a particular week.

  20. ACIS Thermal Control and Observing Strategies

    NASA Astrophysics Data System (ADS)

    Adams-Wolk, Nancy; Aldcroft, T.; Plucinsky, P. P.; Germain, G.

    2011-05-01

    Nearing its 13th observing cycle, the Chandra X-Ray Observatory continues to deliver excellent science to the High Energy community. The orbit of Chandra, and thermal conditions of the spacecraft and instruments have changed over time which has necessitated changes in observing strategies; particularly for the ACIS instrument. This poster focuses on expected changes to be implemented in Cycle 13 for observing with the ACIS instrument. We will focus on the thermal issues with ACIS, including warming of the PSMC, DEA, and Focal Plane. We discuss the causes of the warming of these components of ACIS based on past data, and how this warming can affect observations. Trending studies have strongly suggested changes to the future observing strategies for ACIS. We discuss these changes which include reducing the number of CCDs powered on for temperature sensitive observations, implementing an ACIS FP temperature model to predict temperatures based on spacecraft pitch and pointing, and the use of optional CCDs to reduce the number of CCDs during the planning of a particular week.

  1. Promoting sustainable energy strategies in Russia

    SciTech Connect

    Watson, R.K.

    1995-12-31

    Enormous structural changes are taking place in the economy of Russia. It is important that vital sectors of the economy undergo a smooth transition from a centrally-planned paradigm to a more market-oriented structure. Introducing market-oriented-institutional structures and energy planning approaches to Russian utilities can facilitate the transition to the market and allow them to become vehicles for change rather than mere witnesses. As real electricity prices increase relative to other prices, a significant industrial restructuring can be expected, with an accompanying reduction of energy consumption. By developing programs to help industry become more energy-efficiency, the electricity sector can play a central role in Russia`s economic recovery. A robust energy sector will be in a much better position to lead other sectors of the economy toward market-oriented solutions to the present economic crisis. Because of the magnitude of the task of recreating an economy for one of the world`s superpowers, institutional restructuring should take place incrementally. The transition of US utilities from a {open_quotes}build-and-grow{close_quotes} paradigm to one of Integrated Resource Planning (IRP) and subsequently to a hybrid of competition and IRP began and is continuing on the state and regional level. Local success stories on the West Coast and New England persuaded other states to adopt these methods. This strategy could also prove to be very effective in regions of Russia that are served by integrated electricity grids, such as the South Russia Power pool (Yuzhenergo) that serves the North Caucasus region. As the Russian energy system currently undergoes change, simultaneously privatizing and restructuring, these issues will be largely decided within the next two years. One of the greatest challenges involves implementing an environmentally sustainable strategy which ensures that energy efficiency and renewable energy are incorporated into the new structure.

  2. Gorbachev's arms-control strategy. Final report

    SciTech Connect

    Nogee, J.L.

    1987-01-22

    Soviet foreign policy under the Gorbachev administration, along with domestic policy, has been in a state of flux, particularly in the realm of arms-control policy. Both in substance and style, Gorbachev introduced a new dynamic in arms-control policy. He has skillfully manipulated the issue for propaganda appeal. But also he has shown flexibility in modifying Soviet positions both to respond to U.S. demands and to exert pressure on the United States to reach an agreement. Soviet arms-control objectives (some of which are incompatible) may be realized either through a formal agreement with the United States or without an agreement. These objectives include: (a) to use arms control to build a new framework for relations with the United States to replace detente; (b) to kill the Strategic Defense Initiative; (c) to constrain U.S. development in manned aircraft and cruise missiles (d) to deligitimize nuclear weapons as an instrument of military strategy; (e) to exacerbate differences between the United States and Europe. During his first year in power, Gorbachev relied heavily on propaganda with calls for eliminating nuclear weapons by the 21st century, his test ban moratorium and denunciation of SDI. After the 21st Party Congress he significantly modified Soviet positions closer to those of the United States with his acceptance of the zero option for INF forces, deep cuts in strategic weapons and willingness to accept limited research on SDI. Gorbachev now sees an arms control agreement as essential to his program for domestic reform and is prepared to make genuine concessions to achieve it.

  3. A Composite PWM Control Strategy for Boost Converter

    NASA Astrophysics Data System (ADS)

    Qingfeng, Liu; Zhaoxia, Leng; Jinkun, Sun; Huamin, Wang

    In order to improve the control performance of boost converter with large signal disturbance, a composite PWM control strategy for boost converter operating in continuous condition mode (CCM) was proposed in this paper. The parasitical loss of Boost converter was analyzed and a loss compensation strategy was adopted to design feed-forward tracker for converter. The composite PWM controller consisted of the tracker and PID controller. Simulation and experiment results validated the validity of the control strategy presented in this paper.

  4. Malaria control: achievements, problems and strategies.

    PubMed

    Nájera, J A

    2001-06-01

    scale was steered by the Malaria Commission of the League of Nations and greatly supported by the Rockefeller Foundation. Perhaps the most important contribution of this period was the development of malaria epidemiology, including the study of the genesis of epidemics and their possible forecasting and prevention. Although the great effectiveness of DDT was perhaps the main determinant for proposing the global eradication of the disease in the 1950s, it was the confidence in the epidemiological knowledge and the prestige of malariology, which gave credibility to the proposal at the political level. The second part deals with the global malaria eradication campaign of the 1950s and 1960s. It recognises the enormous impact of the eradication effort in the consolidation of the control successes of the first half of the century, as well as its influence in the development of planning of health programmes. Nevertheless, it also stresses the negative influence that the failure to achieve its utopian expectations had on the general disappointment and slow progress of malaria control, which characterised the last third of the century. The paper then analyses the evolution of malaria control funding, which often appears out of tune with political statements. The fourth part is devoted to the search for realistic approaches to malaria control, leading to the adoption of the global malaria control strategy in Amsterdam in 1992, and the challenge, at the end of the century, to rally forces commensurate with the magnitude of the problem, while aiming at realistic objectives. After discussing the conflicting views on the relations between malaria and socio-economic development and the desirable integration of malaria control into sustainable development, the paper ends with some considerations on the perspectives of malaria control, as seen by the author in early 1998, just before the launching of the current Roll Back Malaria initiative by WHO. PMID:11921521

  5. Strategies for the control of catheter encrustation.

    PubMed

    Stickler, D J; Evans, A; Morris, N; Hughes, G

    2002-06-01

    Two general strategies have been adopted to develop catheter materials that resist encrustaion by bacterial biofilms: (a) the incorporation of antimicrobial agents into the polymers and (b) the production of materials with surface properties which prevent the adherence of bacterial cells. Our experience to develop non-adherent surfaces which abstracts design from nature is reported. Compounds based on 2-methacryloloxyethylphosphorylcholine co-polymerised with long-chain alkyl methacrylates have been produced which have structural and surface properties similar to those of the outer membranes of erythrocytes. These PC-coatings have been applied onto catheter base materials where they produce polar surfaces that are extremely hydrophilic. In experiments using a laboratory model of the catheterised bladder we found that the PC-coatings did not reduce colonisation of latex or silicone catheters by crystalline Proteus mirabilis biofilm. There were no significant difference between the amounts of calcium and magnesium salts deposited on coated and non-coated catheters. In a further set of experiments the PC-coatings did not significantly increase the mean times for which catheters drained freely. In a parallel clinical study, the performance of PC-coated ureteral stents was investigated. Scanning electron microscopy and bacteriological analysis on 44 PC-coated stents that had been implanted in patients for 12-week periods and 28 control stents suggested that the PC-coated devices were less vulnerable to encrustation and colonisation by bacterial biofilm than normal stents. It was of interest that in contrast to encrusted catheters, urease producing species such as P. mirabilis were rarely isolated from the stents. The main organisms colonising the stents were enterococci and coagulase-negative staphylococci. These results suggest that the mechanisms of catheter and stent encrustation may be different and require different strategies for control. PMID:12135840

  6. Intervention strategies for control of foodborne pathogens

    NASA Astrophysics Data System (ADS)

    Juneja, Vijay K.

    2004-03-01

    The increasing numbers of illnesses associated with foodborne pathogens such as Listeria monocytogenes and Escherichia coli O157:H7, has renewed concerns about food safety because of consumer preferences for minimally processed foods that offer convenience in availability and preparation. Accordingly, the need for better control of foodborne pathogens has been paramount in recent years. Mechanical removal of microorganisms from food can be accomplished by centrifugation, filtration, trimming and washing. Cleaning and sanitation strategies can be used for minimizing the access of microorganisms in foods from various sources. Other strategies for control of foodborne pathogens include established physical microbiocidal treatments such as ionizing radiation and heating. Research has continued to demonstrate that food irradiation is a suitable process to control and possibly eliminate foodborne pathogens, for example Listeria monocytogenes and Escherichia coli O157:H7, from a number of raw and cooked meat and poultry products. Heat treatment is the most common method in use today for the inactivation of microorganisms. Microorganisms can also be destroyed by nonthermal treatments, such as application of high hydrostatic pressure, pulsed electric fields, oscillating magnetic fields or a combination of physical processes such as heat-irradiation, or heat-high hydrostatic pressure, etc. Each of the non-thermal technologies has specific applications in terms of the types of food that can be processed. Both conventional and newly developed physical treatments can be used in combination for controlling foodborne pathogens and enhancing the safety and shelf life of foods. Recent research has focused on combining traditional preservation factors with emerging intervention technologies. However, many key issues still need to be addressed for combination preservation factors or technologies to be useful in the food industry to meet public demands for foods with enhanced safety

  7. [Harm reduction strategy in tobacco control].

    PubMed

    Gorini, Giuseppe

    2011-01-01

    .Thus, California Department of Health Services prohibits promotion of snus and medicinal nicotine as a harm reduction strategy. However, the US Federal Family Smoking Prevention and Tobacco Control Act, signed by President Obama in 2009, places tobacco products under FDA jurisdiction: FDA must define criteria for lowering carcinogens and toxicants in tobacco products, making more available medicinal nicotine, evaluating PREPs, creating a federal Tobacco Control Agency.Which approaches is Italy going to follow? PMID:21926451

  8. Machining strategies exploring reduction in energy consumption

    NASA Astrophysics Data System (ADS)

    Mamun, Abdullah Al

    The main aim of this thesis is to explore machining strategies, analyzing energy consumption using Design of Experiments (DOE) at the material removal rate (MRR), compare to cutting geometrical trajectories according to CNC parameters such as spindle RPM, feed rate, depth of cut per pass and total depth of cut. Spindle RPM, depth of cut per pass, and feed rate are selected as the main three factors and each factor has two levels: low-level (-) and high-level (+). These experiments have been performed at an end-milling machine by using a concept of a constant volume of material removal processes in the circular and linear geometrical slots in pine wood blocks. Standard energy logger equipment has used to measure energy consumption during end-milling operation. Different statistical analysis, such as ANOVA, regression line, and cause & effect diagram have used to show different energy consumption results in the material removal process. At the end the of data analysis, it is found that a significant amount of electricity demand is associated with machining pre-cutting & post-cutting stage and this significant amount of electricity demand is defined as peripheral energy. This peripheral energy is not involved in the actual performance of material removal process in the end-milling process. In the [Figure 11] end-milling process has been involved with pine wood blocks at constant volume of material removal (2.8 cubic inch) process. Results can be varied using of hard material removal process, such as steel & aluminum metals.

  9. A novel multimode hybrid energy storage system and its energy management strategy for electric vehicles

    NASA Astrophysics Data System (ADS)

    Wang, Bin; Xu, Jun; Cao, Binggang; Zhou, Xuan

    2015-05-01

    This paper proposes a novel topology of multimode hybrid energy storage system (HESS) and its energy management strategy for electric vehicles (EVs). Compared to the conventional HESS, the proposed multimode HESS has more operating modes and thus it could in further enhance the efficiency of the system. The rule-based control strategy and the power-balancing strategy are developed for the energy management strategy to realize mode selection and power distribution. Generally, the DC-DC converter will operate at peak efficiency to convey the energy from the batteries to the UCs. Otherwise, the pure battery mode or the pure ultracapacitors (UCs) mode will be utilized without the DC-DC converter. To extend the battery life, the UCs have the highest priority to recycle the energy and the batteries are isolated from being recharged directly during regenerative braking. Simulations and experiments are established to validate the proposed multimode HESS and its energy management strategy. The results reveal that the energy losses in the DC-DC converter, the total energy consumption and the overall system efficiency of the proposed multimode HESS are improved compared to the conventional HESS.

  10. 40 CFR 52.1025 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Particulate matter. 52.1025 Section 52.1025 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... strategy: Particulate matter. (a) The revisions to the control strategy resulting from the modification...

  11. 40 CFR 52.1025 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Particulate matter. 52.1025 Section 52.1025 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... strategy: Particulate matter. (a) The revisions to the control strategy resulting from the modification...

  12. 40 CFR 52.1025 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Particulate matter. 52.1025 Section 52.1025 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... strategy: Particulate matter. (a) The revisions to the control strategy resulting from the modification...

  13. 40 CFR 52.1025 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Particulate matter. 52.1025 Section 52.1025 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... strategy: Particulate matter. (a) The revisions to the control strategy resulting from the modification...

  14. 40 CFR 52.1025 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Particulate matter. 52.1025 Section 52.1025 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... strategy: Particulate matter. (a) The revisions to the control strategy resulting from the modification...

  15. 40 CFR 52.2033 - Control strategy: Sulfur oxides.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Sulfur oxides. 52.2033 Section 52.2033 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... strategy: Sulfur oxides. (a) The revision to the control strategy resulting from the modification to...

  16. 40 CFR 52.1476 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Particulate matter... strategy: Particulate matter. (a) The requirements of subpart G of this chapter are not met since the plan... strategy are disapproved since they do not provide the degree of control needed to attain and maintain...

  17. 40 CFR 52.2033 - Control strategy: Sulfur oxides.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 5 2012-07-01 2012-07-01 false Control strategy: Sulfur oxides. 52.2033 Section 52.2033 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... strategy: Sulfur oxides. (a) The revision to the control strategy resulting from the modification to...

  18. 40 CFR 52.2033 - Control strategy: Sulfur oxides.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Sulfur oxides. 52.2033 Section 52.2033 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... strategy: Sulfur oxides. (a) The revision to the control strategy resulting from the modification to...

  19. 40 CFR 52.2033 - Control strategy: Sulfur oxides.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 5 2013-07-01 2013-07-01 false Control strategy: Sulfur oxides. 52.2033 Section 52.2033 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... strategy: Sulfur oxides. (a) The revision to the control strategy resulting from the modification to...

  20. A control strategy for PV stand-alone applications

    NASA Astrophysics Data System (ADS)

    Slouma, S.; Baccar, H.

    2015-04-01

    This paper proposes a stand-alone photovoltaic (PV) system study in domestic applications. Because of the decrease in power of photovoltaic module as a consequence of changes in solar radiation and temperature which affect the photovoltaic module performance, the design and control of DC-DC buck converter was proposed for providing power to the load from a photovoltaic source.In fact, the control of this converter is carried out with integrated MPPT (Maximum Power Point Tracking) algorithm which ensures a maximum energy generated by the PV arrays. Moreover, the output stage is composed by a battery energy storage system, dc-ac inverter, LCL filter which enables higher efficiency, low distortion ac waveforms and low leakage currents. The control strategy adopted is cascade control composed by two regulation loops.Simulations performed with PSIM software were able to validate the control system.The realization and testing of the photovoltaic system were achieved in the Photovoltaic laboratory of the Centre for Research and Energy Technologies at the Technopark Borj Cedria. Experimental results verify the effeciency of the proposed system.

  1. Maximum wind energy extraction strategies using power electronic converters

    NASA Astrophysics Data System (ADS)

    Wang, Quincy Qing

    2003-10-01

    This thesis focuses on maximum wind energy extraction strategies for achieving the highest energy output of variable speed wind turbine power generation systems. Power electronic converters and controls provide the basic platform to accomplish the research of this thesis in both hardware and software aspects. In order to send wind energy to a utility grid, a variable speed wind turbine requires a power electronic converter to convert a variable voltage variable frequency source into a fixed voltage fixed frequency supply. Generic single-phase and three-phase converter topologies, converter control methods for wind power generation, as well as the developed direct drive generator, are introduced in the thesis for establishing variable-speed wind energy conversion systems. Variable speed wind power generation system modeling and simulation are essential methods both for understanding the system behavior and for developing advanced system control strategies. Wind generation system components, including wind turbine, 1-phase IGBT inverter, 3-phase IGBT inverter, synchronous generator, and rectifier, are modeled in this thesis using MATLAB/SIMULINK. The simulation results have been verified by a commercial simulation software package, PSIM, and confirmed by field test results. Since the dynamic time constants for these individual models are much different, a creative approach has also been developed in this thesis to combine these models for entire wind power generation system simulation. An advanced maximum wind energy extraction strategy relies not only on proper system hardware design, but also on sophisticated software control algorithms. Based on literature review and computer simulation on wind turbine control algorithms, an intelligent maximum wind energy extraction control algorithm is proposed in this thesis. This algorithm has a unique on-line adaptation and optimization capability, which is able to achieve maximum wind energy conversion efficiency through

  2. Hierarchical Control Strategy for the Cooperative Braking System of Electric Vehicle

    PubMed Central

    Peng, Jiankun; He, Hongwen; Liu, Wei; Guo, Hongqiang

    2015-01-01

    This paper provides a hierarchical control strategy for cooperative braking system of an electric vehicle with separated driven axles. Two layers are defined: the top layer is used to optimize the braking stability based on two sliding mode control strategies, namely, the interaxle control mode and signal-axle control strategies; the interaxle control strategy generates the ideal braking force distribution in general braking condition, and the single-axle control strategy can ensure braking safety in emergency braking condition; the bottom layer is used to maximize the regenerative braking energy recovery efficiency with a reallocated braking torque strategy; the reallocated braking torque strategy can recovery braking energy as much as possible in the premise of meeting battery charging power. The simulation results show that the proposed hierarchical control strategy is reasonable and can adapt to different typical road surfaces and load cases; the vehicle braking stability and safety can be guaranteed; furthermore, the regenerative braking energy recovery efficiency can be improved. PMID:26236772

  3. Hierarchical Control Strategy for the Cooperative Braking System of Electric Vehicle.

    PubMed

    Peng, Jiankun; He, Hongwen; Liu, Wei; Guo, Hongqiang

    2015-01-01

    This paper provides a hierarchical control strategy for cooperative braking system of an electric vehicle with separated driven axles. Two layers are defined: the top layer is used to optimize the braking stability based on two sliding mode control strategies, namely, the interaxle control mode and signal-axle control strategies; the interaxle control strategy generates the ideal braking force distribution in general braking condition, and the single-axle control strategy can ensure braking safety in emergency braking condition; the bottom layer is used to maximize the regenerative braking energy recovery efficiency with a reallocated braking torque strategy; the reallocated braking torque strategy can recovery braking energy as much as possible in the premise of meeting battery charging power. The simulation results show that the proposed hierarchical control strategy is reasonable and can adapt to different typical road surfaces and load cases; the vehicle braking stability and safety can be guaranteed; furthermore, the regenerative braking energy recovery efficiency can be improved. PMID:26236772

  4. Energy saving strategies of honeybees in dipping nectar

    PubMed Central

    Wu, Jianing; Yang, Heng; Yan, Shaoze

    2015-01-01

    The honeybee’s drinking process has generally been simplified because of its high speed and small scale. In this study, we clearly observed the drinking cycle of the Italian honeybee using a specially designed high-speed camera system. We analysed the pattern of glossal hair erection and the movement kinematics of the protracting tongue (glossa). Results showed that the honeybee used two special protraction strategies to save energy. First, the glossal hairs remain adpressed until the end of the protraction, which indicates that the hydraulic resistance is reduced to less than 1/3 of that in the case if the hairs remain erect. Second, the glossa protracts with a specific velocity profile and we quantitatively demonstrated that this moving strategy helps reduce the total energy needed for protraction compared with the typical form of protraction with constant acceleration and deceleration. These findings suggest effective methods to optimise the control policies employed by next-generation microfluidic pumps. PMID:26446300

  5. Energy saving strategies of honeybees in dipping nectar.

    PubMed

    Wu, Jianing; Yang, Heng; Yan, Shaoze

    2015-01-01

    The honeybee's drinking process has generally been simplified because of its high speed and small scale. In this study, we clearly observed the drinking cycle of the Italian honeybee using a specially designed high-speed camera system. We analysed the pattern of glossal hair erection and the movement kinematics of the protracting tongue (glossa). Results showed that the honeybee used two special protraction strategies to save energy. First, the glossal hairs remain adpressed until the end of the protraction, which indicates that the hydraulic resistance is reduced to less than 1/3 of that in the case if the hairs remain erect. Second, the glossa protracts with a specific velocity profile and we quantitatively demonstrated that this moving strategy helps reduce the total energy needed for protraction compared with the typical form of protraction with constant acceleration and deceleration. These findings suggest effective methods to optimise the control policies employed by next-generation microfluidic pumps. PMID:26446300

  6. Mission aware energy saving strategies for Army ground vehicles

    NASA Astrophysics Data System (ADS)

    Dattathreya, Macam S.

    on, gear is on neutral position, the vehicle is stationary, and the alternator powers the systems. The proposed energy saving strategy for silent surveillance mission minimizes unnecessary battery discharges by controlling the power states of systems according to the mission needs and available battery capacity. Initial experiments show that the proposed approach saves 3% energy when compared with the baseline strategy for one scenario and 1.8% for the second scenario. The proposed energy saving strategy for normal surveillance mission operates the engine at fuel-efficient speeds to meet vehicle demand and to save fuel. The experiment and simulation uses a computerized vehicle model and a test bench to validate the approach. In comparison to vehicles with fixed high-idle engine speed increments, experiments show that the proposed strategy saves fuel energy in the range of 0-4.9% for the tested power demand range of 44-69 kW. It is hoped to implement the proposed strategies on a real Army ground vehicle to start realizing the energy savings.

  7. Behavioral Self-Control Strategies for Young Children

    ERIC Educational Resources Information Center

    Barry, Leasha M.; Haraway, Dana L.

    2005-01-01

    In this paper, self-control strategies are conceptualized as existing on two intersecting continuums of more or less individual control and increasing complexity depending on individual need. Behavioral self-control strategies for young children require external supports to assist children in learning the skills necessary to practice and implement…

  8. Optimal Control of Distributed Energy Resources using Model Predictive Control

    SciTech Connect

    Mayhorn, Ebony T.; Kalsi, Karanjit; Elizondo, Marcelo A.; Zhang, Wei; Lu, Shuai; Samaan, Nader A.; Butler-Purry, Karen

    2012-07-22

    In an isolated power system (rural microgrid), Distributed Energy Resources (DERs) such as renewable energy resources (wind, solar), energy storage and demand response can be used to complement fossil fueled generators. The uncertainty and variability due to high penetration of wind makes reliable system operations and controls challenging. In this paper, an optimal control strategy is proposed to coordinate energy storage and diesel generators to maximize wind penetration while maintaining system economics and normal operation. The problem is formulated as a multi-objective optimization problem with the goals of minimizing fuel costs and changes in power output of diesel generators, minimizing costs associated with low battery life of energy storage and maintaining system frequency at the nominal operating value. Two control modes are considered for controlling the energy storage to compensate either net load variability or wind variability. Model predictive control (MPC) is used to solve the aforementioned problem and the performance is compared to an open-loop look-ahead dispatch problem. Simulation studies using high and low wind profiles, as well as, different MPC prediction horizons demonstrate the efficacy of the closed-loop MPC in compensating for uncertainties in wind and demand.

  9. Improving epidemic control strategies by extended detection

    NASA Astrophysics Data System (ADS)

    Karp, Paweł; Dybiec, Bartłomiej; Kleczkowski, Adam

    2014-11-01

    Majority of epidemics eradication programs work in preventive responsive way. The lack of exact information about epidemiological status of individuals makes responsive actions less efficient. Here, we demonstrate that additional tests can significantly increase the efficiency of "blind" treatment (vaccination or culling). Eradication strategy consisting of "blind" treatment in very limited local neighborhood supplemented by extra tests in a little bit larger neighborhood is able to prevent invasion of even highly infectious diseases and to achieve this at a cost lower than for the "blind" strategy. The effectiveness of the extended strategy depends on such parameters as the test efficiency and test cost.

  10. Selecting a Control Strategy for Plug and Process Loads

    SciTech Connect

    Lobato, C.; Sheppy, M.; Brackney, L.; Pless, S.; Torcellini, P.

    2012-09-01

    Plug and Process Loads (PPLs) are building loads that are not related to general lighting, heating, ventilation, cooling, and water heating, and typically do not provide comfort to the building occupants. PPLs in commercial buildings account for almost 5% of U.S. primary energy consumption. On an individual building level, they account for approximately 25% of the total electrical load in a minimally code-compliant commercial building, and can exceed 50% in an ultra-high efficiency building such as the National Renewable Energy Laboratory's (NREL) Research Support Facility (RSF) (Lobato et al. 2010). Minimizing these loads is a primary challenge in the design and operation of an energy-efficient building. A complex array of technologies that measure and manage PPLs has emerged in the marketplace. Some fall short of manufacturer performance claims, however. NREL has been actively engaged in developing an evaluation and selection process for PPLs control, and is using this process to evaluate a range of technologies for active PPLs management that will cap RSF plug loads. Using a control strategy to match plug load use to users' required job functions is a huge untapped potential for energy savings.

  11. The design and evaluation of integrated envelope and lighting control strategies for commercial buildings

    SciTech Connect

    Lee, E.S.; Selkowitz, S.E.

    1994-06-01

    This study investigates control strategies for coordinating the variable solar-optical properties of a dynamic building envelope system with a daylight controlled electric lighting system to reduce electricity consumption and increase comfort in the perimeter zone of commercial buildings. Control strategy design can be based on either simple, instantaneous measured data, or on complex, predictive algorithms that estimate the energy consumption for a selected operating state of the dynamic envelope and lighting system. The potential benefits of optimizing the operation of a dynamic envelope and lighting system are (1) significant reductions in electrical energy end-uses - lighting, and cooling due to solar and lighting heat gains - over that achieved by conventional static envelope and lighting systems, (2) significant reductions in peak demand, and (3) increased occupant visual and thermal comfort. The DOE-2 building energy simulation program was used to model two dynamic envelope and lighting systems, an automated venetian blind and an electrochromic glazing system, and their control strategies under a range of building conditions. The energy performance of simple control strategies are compared to the optimum performance of a theoretical envelope and lighting system to determine the maximum potential benefit of using more complex, predictive control algorithms. Results indicate that (1) predictive control algorithms may significantly increase the energy-efficiency of systems with non-optimal solar-optical properties such as the automated venetian blind, and (2) simpler, non-predictive control strategies may suffice for more advanced envelope systems 1 incorporating spectrally selective, narrow-band electrochromic coatings.

  12. Internal Roof and Attic Thermal Radiation Control Retrofit Strategies for Cooling-Dominated Climates

    SciTech Connect

    Fallahi, A.; Duraschlag, H.; Elliott, D.; Hartsough, J.; Shukla, N.; Kosny, J.

    2013-12-01

    This project evaluates the cooling energy savings and cost effectiveness of radiation control retrofit strategies for residential attics in U.S. cooling-dominated climates. Usually, in residential applications, radiation control retrofit strategies are applied below the roof deck or on top of the attic floor insulation. They offer an alternative option to the addition of conventional bulk insulation such as fiberglass or cellulose insulation. Radiation control is a potentially low-cost energy efficiency retrofit strategy that does not require significant changes to existing homes. In this project, two groups of low-cost radiation control strategies were evaluated for southern U.S. applications. One uses a radiant barrier composed of two aluminum foils combined with an enclosed reflective air space and the second uses spray-applied interior radiation control coatings (IRCC).

  13. Internal Roof and Attic Thermal Radiation Control Retrofit Strategies for Cooling-Dominated Climates

    SciTech Connect

    Fallahi, A.; Durschlag, H.; Elliott, D.; Hartsough, J.; Shukla, N.; Kosny, J.

    2013-12-01

    This project evaluates the cooling energy savings and cost effectiveness of radiation control retrofit strategies for residential attics in U.S. cooling-dominated climates. Usually, in residential applications, radiation control retrofit strategies are applied below the roof deck or on top of the attic floor insulation. They offer an alternative option to the addition of conventional bulkinsulation such as fiberglass or cellulose insulation. Radiation control is a potentially low-cost energy efficiency retrofit strategy that does not require significant changes to existing homes. In this project, two groups of low-cost radiation control strategies were evaluated for southern U.S. applications. One uses a radiant barrier composed of two aluminum foils combined with an enclosedreflective air space and the second uses spray-applied interior radiation control coatings (IRCC).

  14. Public authority control strategy for opinion evolution in social networks

    NASA Astrophysics Data System (ADS)

    Chen, Xi; Xiong, Xi; Zhang, Minghong; Li, Wei

    2016-08-01

    This paper addresses the need to deal with and control public opinion and rumors. Existing strategies to control public opinion include degree, random, and adaptive bridge control strategies. In this paper, we use the HK model to present a public opinion control strategy based on public authority (PA). This means utilizing the influence of expert or high authority individuals whose opinions we control to obtain the optimum effect in the shortest time possible and thus reach a consensus of public opinion. Public authority (PA) is only influenced by individuals' attributes (age, economic status, and education level) and not their degree distribution; hence, in this paper, we assume that PA complies with two types of public authority distribution (normal and power-law). According to the proposed control strategy, our experiment is based on random, degree, and public authority control strategies in three different social networks (small-world, scale-free, and random) and we compare and analyze the strategies in terms of convergence time (T), final number of controlled agents (C), and comprehensive efficiency (E). We find that different network topologies and the distribution of the PA in the network can influence the final controlling effect. While the effect of PA strategy differs in different network topology structures, all structures achieve comprehensive efficiency with any kind of public authority distribution in any network. Our findings are consistent with several current sociological phenomena and show that in the process of public opinion/rumor control, considerable attention should be paid to high authority individuals.

  15. Public authority control strategy for opinion evolution in social networks.

    PubMed

    Chen, Xi; Xiong, Xi; Zhang, Minghong; Li, Wei

    2016-08-01

    This paper addresses the need to deal with and control public opinion and rumors. Existing strategies to control public opinion include degree, random, and adaptive bridge control strategies. In this paper, we use the HK model to present a public opinion control strategy based on public authority (PA). This means utilizing the influence of expert or high authority individuals whose opinions we control to obtain the optimum effect in the shortest time possible and thus reach a consensus of public opinion. Public authority (PA) is only influenced by individuals' attributes (age, economic status, and education level) and not their degree distribution; hence, in this paper, we assume that PA complies with two types of public authority distribution (normal and power-law). According to the proposed control strategy, our experiment is based on random, degree, and public authority control strategies in three different social networks (small-world, scale-free, and random) and we compare and analyze the strategies in terms of convergence time (T), final number of controlled agents (C), and comprehensive efficiency (E). We find that different network topologies and the distribution of the PA in the network can influence the final controlling effect. While the effect of PA strategy differs in different network topology structures, all structures achieve comprehensive efficiency with any kind of public authority distribution in any network. Our findings are consistent with several current sociological phenomena and show that in the process of public opinion/rumor control, considerable attention should be paid to high authority individuals. PMID:27586601

  16. 40 CFR 52.350 - Control strategy: Ozone.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control strategy: Ozone. 52.350 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Colorado § 52.350 Control strategy: Ozone. (a) Revisions to the Colorado State Implementation Plan, 1-hour ozone NAAQS Redesignation Request and...

  17. 40 CFR 52.66 - Control Strategy: Ozone.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Control Strategy: Ozone. 52.66 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Alabama § 52.66 Control Strategy: Ozone. (a) The redesignation request submitted by the State of Alabama, on March 16, 1995 for the Birmingham marginal...

  18. 40 CFR 52.66 - Control Strategy: Ozone.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control Strategy: Ozone. 52.66 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Alabama § 52.66 Control Strategy: Ozone. (a) The redesignation request submitted by the State of Alabama, on March 16, 1995 for the Birmingham marginal...

  19. 40 CFR 52.930 - Control strategy: Ozone.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control strategy: Ozone. 52.930 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Kentucky § 52.930 Control strategy: Ozone. (a) The VOC..., Campbell and Kenton Counties) ozone nonattainment area. The demonstration of attainment of the...

  20. 40 CFR 52.350 - Control strategy: Ozone.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Control strategy: Ozone. 52.350 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Colorado § 52.350 Control strategy: Ozone. (a) Revisions to the Colorado State Implementation Plan, 1-hour ozone NAAQS Redesignation Request and...

  1. 40 CFR 52.476 - Control strategy: ozone.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... determination, in accordance with 40 CFR 51.918, suspends the requirements for this area to submit an attainment... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Control strategy: ozone. 52.476 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS District of Columbia § 52.476 Control strategy: ozone....

  2. 40 CFR 52.350 - Control strategy: Ozone.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Control strategy: Ozone. 52.350 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Colorado § 52.350 Control strategy: Ozone. (a) Revisions to the Colorado State Implementation Plan, 1-hour ozone NAAQS Redesignation Request and...

  3. 40 CFR 52.476 - Control strategy: ozone.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Control strategy: ozone. 52.476 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS District of Columbia § 52.476 Control strategy: ozone. (a... of Progress Plan for the District of Columbia's portion of the Metropolitan Washington, D.C....

  4. 40 CFR 52.476 - Control strategy: ozone.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... determination, in accordance with 40 CFR 51.918, suspends the requirements for this area to submit an attainment... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Control strategy: ozone. 52.476 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS District of Columbia § 52.476 Control strategy: ozone....

  5. 40 CFR 52.350 - Control strategy: Ozone.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Control strategy: Ozone. 52.350 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Colorado § 52.350 Control strategy: Ozone. (a) Revisions to the Colorado State Implementation Plan, 1-hour ozone NAAQS Redesignation Request and...

  6. 40 CFR 52.66 - Control Strategy: Ozone.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Control Strategy: Ozone. 52.66 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Alabama § 52.66 Control Strategy: Ozone. (a) The redesignation request submitted by the State of Alabama, on March 16, 1995 for the Birmingham marginal...

  7. 40 CFR 52.476 - Control strategy: ozone.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... determination, in accordance with 40 CFR 51.918, suspends the requirements for this area to submit an attainment... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control strategy: ozone. 52.476 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS District of Columbia § 52.476 Control strategy: ozone....

  8. 40 CFR 52.1582 - Control strategy and regulations: Ozone.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... § 52.11582, see the List of CFR Sections Affected, which appears in the Finding Aids section of the... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy and regulations: Ozone... Control strategy and regulations: Ozone. (a) Subchapter 16 of the New Jersey Administrative Code,...

  9. 40 CFR 52.66 - Control Strategy: Ozone.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control Strategy: Ozone. 52.66 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Alabama § 52.66 Control Strategy: Ozone. (a) The redesignation request submitted by the State of Alabama, on March 16, 1995 for the Birmingham marginal...

  10. 40 CFR 52.476 - Control strategy: ozone.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: ozone. 52.476 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS District of Columbia § 52.476 Control strategy: ozone. (a... of Progress Plan for the District of Columbia's portion of the Metropolitan Washington, D.C....

  11. 40 CFR 52.930 - Control strategy: Ozone.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: Ozone. 52.930 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Kentucky § 52.930 Control strategy: Ozone. (a) The VOC..., Campbell and Kenton Counties) ozone nonattainment area. The demonstration of attainment of the...

  12. 40 CFR 52.2429 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ....5 NAAQS has attained the 1997 PM2.5 NAAQS. This determination, in accordance with 40 CFR 52.1004(c... 40 Protection of Environment 5 2012-07-01 2012-07-01 false Control strategy: Particulate matter... Control strategy: Particulate matter. Determination of Attainment. EPA has determined, as of January...

  13. 40 CFR 52.1131 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Particulate matter. 52.1131 Section 52.1131 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) Revisions to the following regulations submitted on March...

  14. 40 CFR 52.2429 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....5 NAAQS has attained the 1997 PM2.5 NAAQS. This determination, in accordance with 40 CFR 52.1004(c... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Particulate matter... Control strategy: Particulate matter. Determination of Attainment. EPA has determined, as of January...

  15. 40 CFR 52.1131 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Particulate matter. 52.1131 Section 52.1131 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) Revisions to the following regulations submitted on March...

  16. 40 CFR 52.477 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... the 1997 PM2.5 NAAQS has attained the 1997 PM2.5 NAAQS. This determination, in accordance with 40 CFR... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Control strategy: Particulate matter... Control strategy: Particulate matter. Determination of Attainment. EPA has determined, as of January...

  17. 40 CFR 52.1131 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Particulate matter. 52.1131 Section 52.1131 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) Revisions to the following regulations submitted on March...

  18. 40 CFR 52.2429 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ....5 NAAQS has attained the 1997 PM2.5 NAAQS. This determination, in accordance with 40 CFR 52.1004(c... 40 Protection of Environment 5 2014-07-01 2014-07-01 false Control strategy: Particulate matter... Control strategy: Particulate matter. Determination of Attainment. EPA has determined, as of January...

  19. 40 CFR 52.477 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... the 1997 PM2.5 NAAQS has attained the 1997 PM2.5 NAAQS. This determination, in accordance with 40 CFR... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Control strategy: Particulate matter... Control strategy: Particulate matter. Determination of Attainment. EPA has determined, as of January...

  20. 40 CFR 52.477 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... the 1997 PM2.5 NAAQS has attained the 1997 PM2.5 NAAQS. This determination, in accordance with 40 CFR... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Control strategy: Particulate matter... Control strategy: Particulate matter. Determination of Attainment. EPA has determined, as of January...

  1. 40 CFR 52.1131 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Particulate matter. 52.1131 Section 52.1131 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) Revisions to the following regulations submitted on March...

  2. 40 CFR 52.1341 - Control strategy: particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... This determination, in accordance with 40 CFR 51.1004(c), suspends the requirements for this area to... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: particulate matter... Control strategy: particulate matter. Determination of Attainment. EPA has determined, as of May 23,...

  3. 40 CFR 52.1374 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Particulate matter. 52.1374 Section 52.1374 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) On July 8, 1997, the Governor of Montana submitted...

  4. 40 CFR 52.477 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... the 1997 PM2.5 NAAQS has attained the 1997 PM2.5 NAAQS. This determination, in accordance with 40 CFR... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control strategy: Particulate matter... Control strategy: Particulate matter. Determination of Attainment. EPA has determined, as of January...

  5. 40 CFR 52.2429 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ....5 NAAQS has attained the 1997 PM2.5 NAAQS. This determination, in accordance with 40 CFR 52.1004(c... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Particulate matter... Control strategy: Particulate matter. Determination of Attainment. EPA has determined, as of January...

  6. 40 CFR 52.1374 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Particulate matter. 52.1374 Section 52.1374 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) On July 8, 1997, the Governor of Montana submitted...

  7. 40 CFR 52.2429 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ....5 NAAQS has attained the 1997 PM2.5 NAAQS. This determination, in accordance with 40 CFR 52.1004(c... 40 Protection of Environment 5 2013-07-01 2013-07-01 false Control strategy: Particulate matter... Control strategy: Particulate matter. Determination of Attainment. EPA has determined, as of January...

  8. 40 CFR 52.2526 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... NAAQS. These determinations, in accordance with 40 CFR 52.1004(c), suspend the requirements for these... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Particulate matter... Control strategy: Particulate matter. (a) EPA approves West Virginia's November 15, 1991 SIP submittal...

  9. 40 CFR 52.2526 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... NAAQS. These determinations, in accordance with 40 CFR 52.1004(c), suspend the requirements for these... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Particulate matter... Control strategy: Particulate matter. (a) EPA approves West Virginia's November 15, 1991 SIP submittal...

  10. 40 CFR 52.1374 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Particulate matter. 52.1374 Section 52.1374 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) On July 8, 1997, the Governor of Montana submitted...

  11. 40 CFR 52.1374 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Particulate matter. 52.1374 Section 52.1374 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) On July 8, 1997, the Governor of Montana submitted...

  12. 40 CFR 52.1375 - Control strategy: Lead.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Lead. 52.1375 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Montana § 52.1375 Control strategy: Lead. Determination—EPA has determined that the East Helena Lead nonattainment area has attained the lead...

  13. 40 CFR 52.1681 - Control strategy: Lead.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Lead. 52.1681 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) New York § 52.1681 Control strategy: Lead. As part of the attainment demonstration for lead, the State of New York has committed to rate all...

  14. 40 CFR 52.58 - Control strategy: Lead.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: Lead. 52.58 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Alabama § 52.58 Control strategy: Lead. The lead plan... the lead standard throughout Alabama. The lead plan submitted by the State on October 7, 1985,...

  15. 40 CFR 52.2236 - Control strategy; lead.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy; lead. 52.2236 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Tennessee § 52.2236 Control strategy; lead... on October 6, 1994. These revisions address the requirements necessary to change a lead...

  16. 40 CFR 52.527 - Control strategy: General.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: General. 52.527 Section 52.527 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Florida § 52.527 Control strategy: General....

  17. 40 CFR 52.1680 - Control strategy: Monitoring and reporting.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Control strategy: Monitoring and reporting. (a) Section 227.6 (a) and (f) are disapproved because they are not consistent with the continuous monitoring and reporting requirements of 40 CFR 51.214. ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Monitoring...

  18. 40 CFR 52.477 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the 1997 PM2.5 NAAQS has attained the 1997 PM2.5 NAAQS. This determination, in accordance with 40 CFR... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: Particulate matter... Control strategy: Particulate matter. Determination of Attainment. EPA has determined, as of January...

  19. 40 CFR 52.573 - Control strategy: General.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: General. 52.573 Section 52.573 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Georgia> § 52.573 Control strategy:...

  20. 40 CFR 52.776 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: Particulate matter. 52.776 Section 52.776 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Indiana § 52.776 Control strategy: Particulate matter. (a) The requirements...

  1. 40 CFR 52.350 - Control strategy: Ozone.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: Ozone. 52.350 Section 52.350 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Colorado § 52.350 Control strategy: Ozone. (a) Revisions to the Colorado State...

  2. 40 CFR 52.582 - Control strategy: Ozone.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: Ozone. 52.582 Section 52.582 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Georgia> § 52.582 Control strategy: Ozone. (a) Approval—The Administrator approves...

  3. National Drug Control Strategy. FY 2009 Budget Summary

    ERIC Educational Resources Information Center

    The White House, 2008

    2008-01-01

    The National Drug Control Budget Summary identifies resources and performance indicators for programs within the Executive Branch that are integral to the President's National Drug Control Strategy. The Strategy, which is the Administration's plan for reducing drug use and availability, is based on three pillars: (1) Stopping Use Before It Starts,…

  4. 40 CFR 52.1131 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Particulate matter. 52.1131 Section 52.1131 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Massachusetts § 52.1131 Control strategy: Particulate matter....

  5. 40 CFR 52.377 - Control strategy: Ozone.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...'s ozone implementation rule (see 40 CFR 51.918), this determination suspends the reasonable further... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Control strategy: Ozone. 52.377 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Connecticut § 52.377 Control strategy: Ozone....

  6. 40 CFR 52.1126 - Control strategy: Sulfur oxides.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Sulfur oxides. 52.1126 Section 52.1126 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Massachusetts § 52.1126 Control strategy: Sulfur oxides. (a) The...

  7. 40 CFR 52.930 - Control strategy: Ozone.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Control strategy: Ozone. 52.930 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Kentucky § 52.930 Control strategy: Ozone. (a) The VOC... nonattainment to attainment was approved on October 23, 2001. The motor vehicle emissions budgets for VOC...

  8. 40 CFR 52.1885 - Control strategy: Ozone.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Ozone. 52.1885 Section 52.1885 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Ohio § 52.1885 Control strategy: Ozone. (a) Part D—Approval. The following...

  9. 40 CFR 52.2575 - Control strategy: Sulfur dioxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Sulfur dioxide. 52... strategy: Sulfur dioxide. (a) Part D—Approval—With the exceptions set forth in this subpart, the Administrator approved the Wisconsin sulfur dioxide control plan. (1) Part D—No action—USEPA takes no action...

  10. 40 CFR 52.928 - Control strategy: Sulfur oxides.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: Sulfur oxides. 52.928 Section 52.928 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Kentucky § 52.928 Control strategy:...

  11. 40 CFR 52.834 - Control strategy: Sulfur dioxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: Sulfur dioxide. 52.834 Section 52.834 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Iowa § 52.834 Control strategy: Sulfur...

  12. 40 CFR 52.57 - Control strategy: Sulfur oxides.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: Sulfur oxides. 52.57... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Alabama § 52.57 Control strategy: Sulfur oxides... for attainment and maintenance of the national standards for sulfur oxides in the vicinity of...

  13. 40 CFR 52.785 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Indiana § 52.785 Control strategy: Carbon... for attainment and maintenance of the national standards for carbon monoxide in the...

  14. 40 CFR 52.785 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Indiana § 52.785 Control strategy: Carbon... for attainment and maintenance of the national standards for carbon monoxide in the...

  15. 40 CFR 52.376 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Connecticut § 52.376 Control strategy: Carbon... submitted a revision to the carbon monoxide State Implementation Plan for the 1990 base year...

  16. 40 CFR 52.349 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... SIP. The Clean Air Campaign was approved into the SIP at 40 CFR 52.320(c)(43)(i)(A). (d) Revisions to... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Colorado § 52.349 Control strategy:...

  17. 40 CFR 52.785 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Indiana § 52.785 Control strategy: Carbon... for attainment and maintenance of the national standards for carbon monoxide in the...

  18. 40 CFR 52.729 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Illinois> § 52.729 Control strategy: Carbon..., Illinois be granted a carbon monoxide (CO) state implementation plan (SIP) revision with...

  19. 40 CFR 52.349 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... SIP. The Clean Air Campaign was approved into the SIP at 40 CFR 52.320(c)(43)(i)(A). (d) Revisions to... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Colorado § 52.349 Control strategy:...

  20. 40 CFR 52.729 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Illinois> § 52.729 Control strategy: Carbon..., Illinois be granted a carbon monoxide (CO) state implementation plan (SIP) revision with...

  1. 40 CFR 52.785 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Indiana § 52.785 Control strategy: Carbon... for attainment and maintenance of the national standards for carbon monoxide in the...

  2. 40 CFR 52.376 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Connecticut § 52.376 Control strategy: Carbon... submitted a revision to the carbon monoxide State Implementation Plan for the 1990 base year...

  3. 40 CFR 52.349 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... SIP. The Clean Air Campaign was approved into the SIP at 40 CFR 52.320(c)(43)(i)(A). (d) Revisions to... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Colorado § 52.349 Control strategy:...

  4. 40 CFR 52.349 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... SIP. The Clean Air Campaign was approved into the SIP at 40 CFR 52.320(c)(43)(i)(A). (d) Revisions to... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Colorado § 52.349 Control strategy:...

  5. 40 CFR 52.729 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Illinois> § 52.729 Control strategy: Carbon..., Illinois be granted a carbon monoxide (CO) state implementation plan (SIP) revision with...

  6. 40 CFR 52.785 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Indiana § 52.785 Control strategy: Carbon... for attainment and maintenance of the national standards for carbon monoxide in the...

  7. 40 CFR 52.729 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Illinois> § 52.729 Control strategy: Carbon..., Illinois be granted a carbon monoxide (CO) state implementation plan (SIP) revision with...

  8. 40 CFR 52.729 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Illinois> § 52.729 Control strategy: Carbon..., Illinois be granted a carbon monoxide (CO) state implementation plan (SIP) revision with...

  9. 40 CFR 52.349 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... SIP. The Clean Air Campaign was approved into the SIP at 40 CFR 52.320(c)(43)(i)(A). (d) Revisions to... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Colorado § 52.349 Control strategy:...

  10. 40 CFR 52.376 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Connecticut § 52.376 Control strategy: Carbon... submitted a revision to the carbon monoxide State Implementation Plan for the 1990 base year...

  11. 40 CFR 52.376 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Connecticut § 52.376 Control strategy: Carbon... submitted a revision to the carbon monoxide State Implementation Plan for the 1990 base year...

  12. 40 CFR 52.376 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Control strategy: Carbon monoxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Connecticut § 52.376 Control strategy: Carbon... submitted a revision to the carbon monoxide State Implementation Plan for the 1990 base year...

  13. 40 CFR 52.527 - Control strategy: General.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control strategy: General. 52.527 Section 52.527 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Florida § 52.527 Control strategy: General....

  14. 40 CFR 52.527 - Control strategy: General.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Control strategy: General. 52.527 Section 52.527 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Florida § 52.527 Control strategy: General....

  15. 40 CFR 52.1374 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Particulate matter. 52.1374 Section 52.1374 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Control strategy: Particulate matter. (a) On July 8, 1997, the Governor of Montana submitted...

  16. 40 CFR 52.378 - Control strategy: PM10.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control strategy: PM10. 52.378 Section 52.378 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Connecticut § 52.378 Control strategy: PM10. (a)...

  17. 40 CFR 52.1680 - Control strategy: Monitoring and reporting.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Control strategy: Monitoring and reporting. (a) Section 227.6 (a) and (f) are disapproved because they are not consistent with the continuous monitoring and reporting requirements of 40 CFR 51.214. ... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Monitoring...

  18. 40 CFR 52.527 - Control strategy: General.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Control strategy: General. 52.527 Section 52.527 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Florida § 52.527 Control strategy: General....

  19. 40 CFR 52.378 - Control strategy: PM10

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Control strategy: PM10 52.378 Section 52.378 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Connecticut § 52.378 Control strategy: PM10 (a)...

  20. 40 CFR 52.1680 - Control strategy: Monitoring and reporting.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Control strategy: Monitoring and reporting. (a) Section 227.6 (a) and (f) are disapproved because they are not consistent with the continuous monitoring and reporting requirements of 40 CFR 51.214. ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Monitoring...

  1. 40 CFR 52.834 - Control strategy: Sulfur dioxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Control strategy: Sulfur dioxide. 52.834 Section 52.834 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Iowa § 52.834 Control strategy: Sulfur...

  2. 40 CFR 52.928 - Control strategy: Sulfur oxides.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control strategy: Sulfur oxides. 52.928 Section 52.928 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Kentucky § 52.928 Control strategy:...

  3. 40 CFR 52.834 - Control strategy: Sulfur dioxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Control strategy: Sulfur dioxide. 52.834 Section 52.834 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Iowa § 52.834 Control strategy: Sulfur...

  4. 40 CFR 52.57 - Control strategy: Sulfur oxides.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control strategy: Sulfur oxides. 52.57... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Alabama § 52.57 Control strategy: Sulfur oxides... for attainment and maintenance of the national standards for sulfur oxides in the vicinity of...

  5. 40 CFR 52.928 - Control strategy: Sulfur oxides.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Control strategy: Sulfur oxides. 52.928 Section 52.928 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Kentucky § 52.928 Control strategy:...

  6. 40 CFR 52.57 - Control strategy: Sulfur oxides.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Control strategy: Sulfur oxides. 52.57... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Alabama § 52.57 Control strategy: Sulfur oxides... for attainment and maintenance of the national standards for sulfur oxides in the vicinity of...

  7. 40 CFR 52.928 - Control strategy: Sulfur oxides.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Control strategy: Sulfur oxides. 52.928 Section 52.928 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Kentucky § 52.928 Control strategy:...

  8. 40 CFR 52.928 - Control strategy: Sulfur oxides.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Control strategy: Sulfur oxides. 52.928 Section 52.928 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Kentucky § 52.928 Control strategy:...

  9. 40 CFR 52.2575 - Control strategy: Sulfur dioxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Sulfur dioxide. 52... strategy: Sulfur dioxide. (a) Part D—Approval—With the exceptions set forth in this subpart, the Administrator approved the Wisconsin sulfur dioxide control plan. (1) Part D—No action—USEPA takes no action...

  10. 40 CFR 52.2575 - Control strategy: Sulfur dioxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 5 2014-07-01 2014-07-01 false Control strategy: Sulfur dioxide. 52... strategy: Sulfur dioxide. (a) Part D—Approval—With the exceptions set forth in this subpart, the Administrator approved the Wisconsin sulfur dioxide control plan. (1) Part D—No action—USEPA takes no action...

  11. 40 CFR 52.57 - Control strategy: Sulfur oxides.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Control strategy: Sulfur oxides. 52.57... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Alabama § 52.57 Control strategy: Sulfur oxides... for attainment and maintenance of the national standards for sulfur oxides in the vicinity of...

  12. 40 CFR 52.2575 - Control strategy: Sulfur dioxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 5 2013-07-01 2013-07-01 false Control strategy: Sulfur dioxide. 52... strategy: Sulfur dioxide. (a) Part D—Approval—With the exceptions set forth in this subpart, the Administrator approved the Wisconsin sulfur dioxide control plan. (1) Part D—No action—USEPA takes no action...

  13. 40 CFR 52.834 - Control strategy: Sulfur dioxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control strategy: Sulfur dioxide. 52.834 Section 52.834 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Iowa § 52.834 Control strategy: Sulfur...

  14. 40 CFR 52.2575 - Control strategy: Sulfur dioxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 5 2012-07-01 2012-07-01 false Control strategy: Sulfur dioxide. 52... strategy: Sulfur dioxide. (a) Part D—Approval—With the exceptions set forth in this subpart, the Administrator approved the Wisconsin sulfur dioxide control plan. (1) Part D—No action—USEPA takes no action...

  15. 40 CFR 52.57 - Control strategy: Sulfur oxides.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Control strategy: Sulfur oxides. 52.57... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Alabama § 52.57 Control strategy: Sulfur oxides... for attainment and maintenance of the national standards for sulfur oxides in the vicinity of...

  16. 40 CFR 52.834 - Control strategy: Sulfur dioxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Control strategy: Sulfur dioxide. 52.834 Section 52.834 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Iowa § 52.834 Control strategy: Sulfur...

  17. 40 CFR 52.2236 - Control strategy; lead.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 5 2014-07-01 2014-07-01 false Control strategy; lead. 52.2236 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Tennessee § 52.2236 Control strategy; lead... SIP on October 6, 1994. These revisions address the requirements necessary to change a...

  18. 40 CFR 52.1681 - Control strategy: Lead.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Lead. 52.1681 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) New York § 52.1681 Control strategy: Lead. As part of the attainment demonstration for lead, the State of New York has committed to rate all...

  19. 40 CFR 52.1681 - Control strategy: Lead.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Lead. 52.1681 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) New York § 52.1681 Control strategy: Lead. As part of the attainment demonstration for lead, the State of New York has committed to rate all...

  20. 40 CFR 52.797 - Control strategy: Lead.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Control strategy: Lead. 52.797 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Indiana § 52.797 Control strategy: Lead. (a)-(b) (c) On... redesignate the County to attainment of the lead standard. (e) On April 1, 2009, Indiana submitted an...

  1. 40 CFR 52.1681 - Control strategy: Lead.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Lead. 52.1681 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) New York § 52.1681 Control strategy: Lead. As part of the attainment demonstration for lead, the State of New York has committed to rate all...

  2. 40 CFR 52.797 - Control strategy: Lead.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control strategy: Lead. 52.797 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Indiana § 52.797 Control strategy: Lead. (a)-(b) (c) On... redesignate the County to attainment of the lead standard. (e) On April 1, 2009, Indiana submitted an...

  3. 40 CFR 52.1375 - Control strategy: Lead.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Lead. 52.1375 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Montana § 52.1375 Control strategy: Lead. Determination—EPA has determined that the East Helena Lead nonattainment area has attained the lead...

  4. 40 CFR 52.1375 - Control strategy: Lead.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Lead. 52.1375 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Montana § 52.1375 Control strategy: Lead. Determination—EPA has determined that the East Helena Lead nonattainment area has attained the lead...

  5. 40 CFR 52.797 - Control strategy: Lead.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Control strategy: Lead. 52.797 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Indiana § 52.797 Control strategy: Lead. (a)-(b) (c) On... redesignate the County to attainment of the lead standard. (e) On April 1, 2009, Indiana submitted an...

  6. 40 CFR 52.58 - Control strategy: Lead.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Control strategy: Lead. 52.58 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Alabama § 52.58 Control strategy: Lead. The lead plan... the lead standard throughout Alabama. The lead plan submitted by the State on October 7, 1985,...

  7. 40 CFR 52.58 - Control strategy: Lead.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Control strategy: Lead. 52.58 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Alabama § 52.58 Control strategy: Lead. The lead plan... the lead standard throughout Alabama. The lead plan submitted by the State on October 7, 1985,...

  8. 40 CFR 52.58 - Control strategy: Lead.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Control strategy: Lead. 52.58 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Alabama § 52.58 Control strategy: Lead. The lead plan... the lead standard throughout Alabama. The lead plan submitted by the State on October 7, 1985,...

  9. 40 CFR 52.58 - Control strategy: Lead.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control strategy: Lead. 52.58 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Alabama § 52.58 Control strategy: Lead. The lead plan... the lead standard throughout Alabama. The lead plan submitted by the State on October 7, 1985,...

  10. 40 CFR 52.2236 - Control strategy; lead.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 5 2013-07-01 2013-07-01 false Control strategy; lead. 52.2236 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Tennessee § 52.2236 Control strategy; lead... SIP on October 6, 1994. These revisions address the requirements necessary to change a...

  11. 40 CFR 52.2236 - Control strategy; lead.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 5 2012-07-01 2012-07-01 false Control strategy; lead. 52.2236 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Tennessee § 52.2236 Control strategy; lead... on October 6, 1994. These revisions address the requirements necessary to change a lead...

  12. 40 CFR 52.1681 - Control strategy: Lead.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Lead. 52.1681 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) New York § 52.1681 Control strategy: Lead. As part of the attainment demonstration for lead, the State of New York has committed to rate all...

  13. 40 CFR 52.1375 - Control strategy: Lead.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Lead. 52.1375 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Montana § 52.1375 Control strategy: Lead. Determination—EPA has determined that the East Helena Lead nonattainment area has attained the lead...

  14. 40 CFR 52.2236 - Control strategy; lead.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy; lead. 52.2236 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Tennessee § 52.2236 Control strategy; lead... on October 6, 1994. These revisions address the requirements necessary to change a lead...

  15. 40 CFR 52.1375 - Control strategy: Lead.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Lead. 52.1375 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Montana § 52.1375 Control strategy: Lead. Determination—EPA has determined that the East Helena Lead nonattainment area has attained the lead...

  16. 40 CFR 52.65 - Control Strategy: Nitrogen oxides.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Control Strategy: Nitrogen oxides. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Alabama § 52.65 Control Strategy: Nitrogen... using to implement provisions of the Prevention of Significant Deterioration regulations for...

  17. 40 CFR 52.728 - Control strategy: Nitrogen dioxide. [Reserved

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control strategy: Nitrogen dioxide. 52.728 Section 52.728 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Illinois> § 52.728 Control strategy:...

  18. 40 CFR 52.1676 - Control strategy: Nitrogen dioxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... August 10, 1979, is disapproved because it is inconsistent with 40 CFR Subpart G, Control strategy... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Nitrogen dioxide. 52...: Nitrogen dioxide. (a) The requirements of § 52.14(c)(3) of this chapter as of May 8, 1974 (39 FR...

  19. 40 CFR 52.728 - Control strategy: Nitrogen dioxide. [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: Nitrogen dioxide. 52.728 Section 52.728 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Illinois> § 52.728 Control strategy:...

  20. 40 CFR 52.1676 - Control strategy: Nitrogen dioxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... August 10, 1979, is disapproved because it is inconsistent with 40 CFR Subpart G, Control strategy... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Nitrogen dioxide. 52...: Nitrogen dioxide. (a) The requirements of § 52.14(c)(3) of this chapter as of May 8, 1974 (39 FR...

  1. 40 CFR 52.1676 - Control strategy: Nitrogen dioxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... August 10, 1979, is disapproved because it is inconsistent with 40 CFR Subpart G, Control strategy... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Nitrogen dioxide. 52...: Nitrogen dioxide. (a) The requirements of § 52.14(c)(3) of this chapter as of May 8, 1974 (39 FR...

  2. 40 CFR 52.1676 - Control strategy: Nitrogen dioxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... August 10, 1979, is disapproved because it is inconsistent with 40 CFR Subpart G, Control strategy... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Nitrogen dioxide. 52...: Nitrogen dioxide. (a) The requirements of § 52.14(c)(3) of this chapter as of May 8, 1974 (39 FR...

  3. 40 CFR 52.728 - Control strategy: Nitrogen dioxide. [Reserved

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Control strategy: Nitrogen dioxide. 52.728 Section 52.728 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Illinois> § 52.728 Control strategy:...

  4. 40 CFR 52.728 - Control strategy: Nitrogen dioxide. [Reserved

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Control strategy: Nitrogen dioxide. 52.728 Section 52.728 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Illinois> § 52.728 Control strategy:...

  5. 40 CFR 52.65 - Control Strategy: Nitrogen oxides.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Control Strategy: Nitrogen oxides. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Alabama § 52.65 Control Strategy: Nitrogen... using to implement provisions of the Prevention of Significant Deterioration regulations for...

  6. 40 CFR 52.728 - Control strategy: Nitrogen dioxide. [Reserved

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Control strategy: Nitrogen dioxide. 52.728 Section 52.728 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Illinois> § 52.728 Control strategy:...

  7. 40 CFR 52.65 - Control Strategy: Nitrogen oxides.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control Strategy: Nitrogen oxides. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Alabama § 52.65 Control Strategy: Nitrogen... using to implement provisions of the Prevention of Significant Deterioration regulations for...

  8. 40 CFR 52.1676 - Control strategy: Nitrogen dioxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... August 10, 1979, is disapproved because it is inconsistent with 40 CFR Subpart G, Control strategy... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Nitrogen dioxide. 52...: Nitrogen dioxide. (a) The requirements of § 52.14(c)(3) of this chapter as of May 8, 1974 (39 FR...

  9. 40 CFR 52.1982 - Control strategy: Ozone.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Ozone. 52.1982... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Oregon § 52.1982 Control strategy... approximately 1,200 gasoline service stations where compliance is determined by observing whether...

  10. 40 CFR 52.724 - Control strategy: Sulfur dioxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Control strategy: Sulfur dioxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Illinois> § 52.724 Control strategy: Sulfur... comply.) 3 Source is in compliance per 204(e)(3). CIPS=Central Illinois Public Service....

  11. 40 CFR 52.724 - Control strategy: Sulfur dioxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Control strategy: Sulfur dioxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Illinois> § 52.724 Control strategy: Sulfur... comply.) 3 Source is in compliance per 204(e)(3). CIPS=Central Illinois Public Service....

  12. 40 CFR 52.724 - Control strategy: Sulfur dioxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control strategy: Sulfur dioxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Illinois> § 52.724 Control strategy: Sulfur... comply.) 3 Source is in compliance per 204(e)(3). CIPS=Central Illinois Public Service....

  13. 40 CFR 52.1982 - Control strategy: Ozone.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Ozone. 52.1982... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Oregon § 52.1982 Control strategy... approximately 1,200 gasoline service stations where compliance is determined by observing whether...

  14. 40 CFR 52.1982 - Control strategy: Ozone.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Ozone. 52.1982... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Oregon § 52.1982 Control strategy... approximately 1,200 gasoline service stations where compliance is determined by observing whether...

  15. 40 CFR 52.1982 - Control strategy: Ozone.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Ozone. 52.1982... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Oregon § 52.1982 Control strategy... approximately 1,200 gasoline service stations where compliance is determined by observing whether...

  16. 40 CFR 52.724 - Control strategy: Sulfur dioxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Control strategy: Sulfur dioxide. 52... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Illinois> § 52.724 Control strategy: Sulfur... comply.) 3 Source is in compliance per 204(e)(3). CIPS=Central Illinois Public Service....

  17. 40 CFR 52.1982 - Control strategy: Ozone.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Ozone. 52.1982... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Oregon § 52.1982 Control strategy... approximately 1,200 gasoline service stations where compliance is determined by observing whether...

  18. 40 CFR 52.2585 - Control strategy: Ozone.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Ozone. 52.2585 Section 52.2585 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Wisconsin § 52.2585 Control strategy: Ozone. (a) Disapproval—On November 6,...

  19. 40 CFR 52.1174 - Control strategy: Ozone.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Ozone. 52.1174 Section 52.1174 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Michigan § 52.1174 Control strategy: Ozone. (a) Part...

  20. 40 CFR 52.1174 - Control strategy: Ozone.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Ozone. 52.1174 Section 52.1174 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Michigan § 52.1174 Control strategy: Ozone. (a) Part...

  1. 40 CFR 52.1174 - Control strategy: Ozone.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Ozone. 52.1174 Section 52.1174 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Michigan § 52.1174 Control strategy: Ozone. (a) Part...

  2. Energy strategies for oil-importing developing countries

    SciTech Connect

    Munasinghe, M.

    1984-04-01

    The author analyzes the impact of the past oil crises on the world economy in general, and on the oil importers in particular. He identifies possible adjustment strategies that the oil-importing developing countries (OIDCs) might adopt in the coming years. Energy planning will generally require the coordinated use of interrelated policy tools such as physical controls and legislation, technical methods (including research and development), direct investments or investment-inducing policies, education and propaganda, and pricing. The broad energy options available to OIDCs are efficiency improvements to both energy supply and consumption, an increased pace of developing indigenous resources, and a restructing of their economies for longer-run payoffs. 12 references, 1 figure, 1 table.

  3. Global lessons from Nigeria's ebolavirus control strategy.

    PubMed

    Elemuwa, Chris; Kutalek, Ruth; Ali, Mohammad; Mworozi, Edison; Kochhar, Sonali; Rath, Barbara

    2015-01-01

    The current Ebola virus disease outbreak challenged medical and public health systems in West Africa. In Nigeria, the existing infrastructure of the polio surveillance system was leveraged rapidly to contain the spread of Ebola virus. We highlight important lessons learnt from the successful implementation of Ebola virus disease surveillance strategies, which should be amplified further to prepare the ground for successful vaccination programs. Close collaboration between national and international stakeholders as well as public/private partnerships will be instrumental in future Ebola virus immunization strategies. PMID:26190046

  4. An extended signal control strategy for urban network traffic flow

    NASA Astrophysics Data System (ADS)

    Yan, Fei; Tian, Fuli; Shi, Zhongke

    2016-03-01

    Traffic flow patterns are in general repeated on a daily or weekly basis. To improve the traffic conditions by using the inherent repeatability of traffic flow, a novel signal control strategy for urban networks was developed via iterative learning control (ILC) approach. Rigorous analysis shows that the proposed learning control method can guarantee the asymptotic convergence. The impacts of the ILC-based signal control strategy on the macroscopic fundamental diagram (MFD) were analyzed by simulations on a test road network. The results show that the proposed ILC strategy can evenly distribute the accumulation in the network and improve the network mobility.

  5. SANITARY-SEWER OVERFLOW CONTROL STRATEGY

    EPA Science Inventory

    This paper presents a strategy for the abatement of pollution from storm-generated sanitary-sewer overflows (SSO). Because of the great lengths of sanitary-sewer systems and their associated vast number of house-service laterals or building connections, it is often less expensive...

  6. The National Drug Control Strategy, 1997.

    ERIC Educational Resources Information Center

    Office of National Drug Control Policy, Washington, DC.

    This federal document offers a comprehensive approach to reduce demand for illegal drugs and decrease their availability. Supported by statistical tables and graphs, the summary is divided into six sections. "The Purpose and Nature of the Strategy" outlines a 10-year plan for drug interdiction and reduction and identifies the elements of that…

  7. Adaptive control strategies for flexible robotic arm

    NASA Technical Reports Server (NTRS)

    Bialasiewicz, Jan T.

    1993-01-01

    The motivation of this research came about when a neural network direct adaptive control scheme was applied to control the tip position of a flexible robotic arm. Satisfactory control performance was not attainable due to the inherent non-minimum phase characteristics of the flexible robotic arm tip. Most of the existing neural network control algorithms are based on the direct method and exhibit very high sensitivity if not unstable closed-loop behavior. Therefore a neural self-tuning control (NSTC) algorithm is developed and applied to this problem and showed promising results. Simulation results of the NSTC scheme and the conventional self-tuning (STR) control scheme are used to examine performance factors such as control tracking mean square error, estimation mean square error, transient response, and steady state response.

  8. A computer simulation approach to measurement of human control strategy

    NASA Technical Reports Server (NTRS)

    Green, J.; Davenport, E. L.; Engler, H. F.; Sears, W. E., III

    1982-01-01

    Human control strategy is measured through use of a psychologically-based computer simulation which reflects a broader theory of control behavior. The simulation is called the human operator performance emulator, or HOPE. HOPE was designed to emulate control learning in a one-dimensional preview tracking task and to measure control strategy in that setting. When given a numerical representation of a track and information about current position in relation to that track, HOPE generates positions for a stick controlling the cursor to be moved along the track. In other words, HOPE generates control stick behavior corresponding to that which might be used by a person learning preview tracking.

  9. A multiple pointing-mount control strategy for space platforms

    NASA Technical Reports Server (NTRS)

    Johnson, C. D.

    1992-01-01

    A new disturbance-adaptive control strategy for multiple pointing-mount space platforms is proposed and illustrated by consideration of a simplified 3-link dynamic model of a multiple pointing-mount space platform. Simulation results demonstrate the effectiveness of the new platform control strategy. The simulation results also reveal a system 'destabilization phenomena' that can occur if the set of individual platform-mounted experiment controllers are 'too responsive.'

  10. Strategies for Energy Efficient Remodeling: SEER 2003 Case Study Report

    SciTech Connect

    2004-11-01

    The goal of the Strategies for Energy Efficiency in Remodeling (SEER) project is to provide information, based on research and case studies, to remodelers and consumers about opportunities to increase home energy performance.

  11. Control strategy optimization of HVAC plants

    SciTech Connect

    Facci, Andrea Luigi; Zanfardino, Antonella; Martini, Fabrizio; Pirozzi, Salvatore; Ubertini, Stefano

    2015-03-10

    In this paper we present a methodology to optimize the operating conditions of heating, ventilation and air conditioning (HVAC) plants to achieve a higher energy efficiency in use. Semi-empiric numerical models of the plant components are used to predict their performances as a function of their set-point and the environmental and occupied space conditions. The optimization is performed through a graph-based algorithm that finds the set-points of the system components that minimize energy consumption and/or energy costs, while matching the user energy demands. The resulting model can be used with systems of almost any complexity, featuring both HVAC components and energy systems, and is sufficiently fast to make it applicable to real-time setting.

  12. Recommended Ventilation Strategies for Energy-Efficient Production Homes

    SciTech Connect

    Roberson, J.; Brown, R.; Koomey, J.; Warner, J.; Greenberg, S.

    1998-12-01

    This report evaluates residential ventilation systems for the U.S. Environmental Protection Agency's (EPA's) ENERGY STAR{reg_sign} Homes program and recommends mechanical ventilation strategies for new, low-infiltration, energy-efficient, single-family, ENERGY STAR production (site-built tract) homes in four climates: cold, mixed (cold and hot), hot humid, and hot arid. Our group in the Energy Analysis Department at Lawrence Berkeley National Lab compared residential ventilation strategies in four climates according to three criteria: total annualized costs (the sum of annualized capital cost and annual operating cost), predominant indoor pressure induced by the ventilation system, and distribution of ventilation air within the home. The mechanical ventilation systems modeled deliver 0.35 air changes per hour continuously, regardless of actual infiltration or occupant window-opening behavior. Based on the assumptions and analysis described in this report, we recommend independently ducted multi-port supply ventilation in all climates except cold because this strategy provides the safety and health benefits of positive indoor pressure as well as the ability to dehumidify and filter ventilation air. In cold climates, we recommend that multi-port supply ventilation be balanced by a single-port exhaust ventilation fan, and that builders offer balanced heat-recovery ventilation to buyers as an optional upgrade. For builders who continue to install forced-air integrated supply ventilation, we recommend ensuring ducts are airtight or in conditioned space, installing a control that automatically operates the forced-air fan 15-20 minutes during each hour that the fan does not operate for heating or cooling, and offering ICM forced-air fans to home buyers as an upgrade.

  13. Health benefit modelling and optimization of vehicular pollution control strategies

    NASA Astrophysics Data System (ADS)

    Sonawane, Nayan V.; Patil, Rashmi S.; Sethi, Virendra

    2012-12-01

    This study asserts that the evaluation of pollution reduction strategies should be approached on the basis of health benefits. The framework presented could be used for decision making on the basis of cost effectiveness when the strategies are applied concurrently. Several vehicular pollution control strategies have been proposed in literature for effective management of urban air pollution. The effectiveness of these strategies has been mostly studied as a one at a time approach on the basis of change in pollution concentration. The adequacy and practicality of such an approach is studied in the present work. Also, the assessment of respective benefits of these strategies has been carried out when they are implemented simultaneously. An integrated model has been developed which can be used as a tool for optimal prioritization of various pollution management strategies. The model estimates health benefits associated with specific control strategies. ISC-AERMOD View has been used to provide the cause-effect relation between control options and change in ambient air quality. BenMAP, developed by U.S. EPA, has been applied for estimation of health and economic benefits associated with various management strategies. Valuation of health benefits has been done for impact indicators of premature mortality, hospital admissions and respiratory syndrome. An optimization model has been developed to maximize overall social benefits with determination of optimized percentage implementations for multiple strategies. The model has been applied for sub-urban region of Mumbai city for vehicular sector. Several control scenarios have been considered like revised emission standards, electric, CNG, LPG and hybrid vehicles. Reduction in concentration and resultant health benefits for the pollutants CO, NOx and particulate matter are estimated for different control scenarios. Finally, an optimization model has been applied to determine optimized percentage implementation of specific

  14. Can Tribes Control Energy Development?

    ERIC Educational Resources Information Center

    Owens, Nancy J.

    1979-01-01

    Emphasizing that the Indian future does not have to be bleak if only Indians take greater control over energy development on their lands. Two-thirds of the total Indian population control 33 percent of U.S. low-sulfer, strippable coal; 80 percent of U.S. uranium reserves; and about 10 percent of petroleum and gas reserves. (Author/RTS)

  15. Adaptive bridge control strategy for opinion evolution on social networks

    NASA Astrophysics Data System (ADS)

    Qian, Cheng; Cao, Jinde; Lu, Jianquan; Kurths, Jürgen

    2011-06-01

    In this paper, we present an efficient opinion control strategy for complex networks, in particular, for social networks. The proposed adaptive bridge control (ABC) strategy calls for controlling a special kind of nodes named bridge and requires no knowledge of the node degrees or any other global or local knowledge, which are necessary for some other immunization strategies including targeted immunization and acquaintance immunization. We study the efficiency of the proposed ABC strategy on random networks, small-world networks, scale-free networks, and the random networks adjusted by the edge exchanging method. Our results show that the proposed ABC strategy is efficient for all of these four kinds of networks. Through an adjusting clustering coefficient by the edge exchanging method, it is found out that the efficiency of our ABC strategy is closely related with the clustering coefficient. The main contributions of this paper can be listed as follows: (1) A new high-order social network is proposed to describe opinion dynamic. (2) An algorithm, which does not require the knowledge of the nodes' degree and other global/local network structure information, is proposed to control the "bridges" more accurately and further control the opinion dynamics of the social networks. The efficiency of our ABC strategy is illustrated by numerical examples. (3) The numerical results indicate that our ABC strategy is more efficient for networks with higher clustering coefficient.

  16. Analysis of Alternative Mercury Control Strategies

    EIA Publications

    2005-01-01

    This analysis responds to a September 14, 2004, request from Chairmen James M. Inhofe and George V. Voinovich asking the Energy Information Administration (EIA) to analyze the impacts of different approaches for removing mercury from coal-fired power plants.

  17. Control system options and strategies for supercritical CO2 cycles.

    SciTech Connect

    Moisseytsev, A.; Kulesza, K. P.; Sienicki, J. J.; Nuclear Engineering Division; Oregon State Univ.

    2009-06-18

    The Supercritical Carbon Dioxide (S-CO{sub 2}) Brayton Cycle is a promising alternative to Rankine steam cycle and recuperated gas Brayton cycle energy converters for use with Sodium-Cooled Fast Reactors (SFRs), Lead-Cooled Fast Reactors (LFRs), as well as other advanced reactor concepts. The S-CO{sub 2} Brayton Cycle offers higher plant efficiencies than Rankine or recuperated gas Brayton cycles operating at the same liquid metal reactor core outlet temperatures as well as reduced costs or size of key components especially the turbomachinery. A new Plant Dynamics Computer Code has been developed at Argonne National Laboratory for simulation of a S-CO{sub 2} Brayton Cycle energy converter coupled to an autonomous load following liquid metal-cooled fast reactor. The Plant Dynamics code has been applied to investigate the effectiveness of a control strategy for the S-CO{sub 2} Brayton Cycle for the STAR-LM 181 MWe (400 MWt) Lead-Cooled Fast Reactor. The strategy, which involves a combination of control mechanisms, is found to be effective for controlling the S-CO{sub 2} Brayton Cycle over the complete operating range from 0 to 100 % load for a representative set of transient load changes. While the system dynamic analysis of control strategy performance for STARLM is carried out for a S-CO{sub 2} Brayton Cycle energy converter incorporating an axial flow turbine and compressors, investigations of the S-CO{sub 2} Brayton Cycle have identified benefits from the use of centrifugal compressors which offer a wider operating range, greater stability near the critical point, and potentially further cost reductions due to fewer stages than axial flow compressors. Models have been developed at Argonne for the conceptual design and performance analysis of centrifugal compressors for use in the SCO{sub 2} Brayton Cycle. Steady state calculations demonstrate the wider operating range of centrifugal compressors versus axial compressors installed in a S-CO{sub 2} Brayton Cycle as

  18. Efficient community-based control strategies in adaptive networks

    NASA Astrophysics Data System (ADS)

    Yang, Hui; Tang, Ming; Zhang, Hai-Feng

    2012-12-01

    Most studies on adaptive networks concentrate on the properties of steady state, but neglect transient dynamics. In this study, we pay attention to the emergence of community structure in the transient process and the effects of community-based control strategies on epidemic spreading. First, by normalizing the modularity, we investigate the evolution of community structure during the transient process, and find that a strong community structure is induced by the rewiring mechanism in the early stage of epidemic dynamics, which, remarkably, delays the outbreak of disease. We then study the effects of control strategies started at different stages on the prevalence. Both immunization and quarantine strategies indicate that it is not ‘the earlier, the better’ for the implementation of control measures. And the optimal control effect is obtained if control measures can be efficiently implemented in the period of a strong community structure. For the immunization strategy, immunizing the susceptible nodes on susceptible-infected links and immunizing susceptible nodes randomly have similar control effects. However, for the quarantine strategy, quarantining the infected nodes on susceptible-infected links can yield a far better result than quarantining infected nodes randomly. More significantly, the community-based quarantine strategy performs better than the community-based immunization strategy. This study may shed new light on the forecast and the prevention of epidemics among humans.

  19. Investigation of energy management strategies for photovoltaic systems - An analysis technique

    NASA Technical Reports Server (NTRS)

    Cull, R. C.; Eltimsahy, A. H.

    1982-01-01

    Progress is reported in formulating energy management strategies for stand-alone PV systems, developing an analytical tool that can be used to investigate these strategies, applying this tool to determine the proper control algorithms and control variables (controller inputs and outputs) for a range of applications, and quantifying the relative performance and economics when compared to systems that do not apply energy management. The analysis technique developed may be broadly applied to a variety of systems to determine the most appropriate energy management strategies, control variables and algorithms. The only inputs required are statistical distributions for stochastic energy inputs and outputs of the system and the system's device characteristics (efficiency and ratings). Although the formulation was originally driven by stand-alone PV system needs, the techniques are also applicable to hybrid and grid connected systems.

  20. CHOOSING OPTIMUM MANAGEMENT STRATEGIES FOR POLLUTION CONTROL

    EPA Science Inventory

    This seminar publication is addressed to managers and supervisors who have some responsibility for their plant's pollution control measures. The information and guidance provided to these decision personnel are drawn from case histories of working plants and include laws, regulat...

  1. An overview of energy strategies for Jamaica

    SciTech Connect

    Palmedo, P.F.; Ashby, W.R.; Doernberg, A.; Tunnah, B.

    1981-05-25

    Jamaica, with a virtual total dependence on imported oil, must develop alternative energy sources if expected GNP growth rates are to be achieved. This study selectively assesses alternative energy techniques and places Jamaica's various energy options in perspective according to anticipated levels of energy demand. The major energy options considered include use of coal and peat in industry and electric generation; promotion of energy conservation in industry, transportation, and utilities; hydropower; solar power; and biomass generation.

  2. 40 CFR 52.1486 - Control strategy: Hydrocarbons and ozone.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Hydrocarbons and ozone. 52.1486 Section 52.1486 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... strategy: Hydrocarbons and ozone. (a) The requirements of subpart G of this chapter are not met since...

  3. 40 CFR 52.1486 - Control strategy: Hydrocarbons and ozone.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Hydrocarbons and ozone. 52.1486 Section 52.1486 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... strategy: Hydrocarbons and ozone. (a) The requirements of subpart G of this chapter are not met since...

  4. 40 CFR 52.1486 - Control strategy: Hydrocarbons and ozone.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Hydrocarbons and ozone. 52.1486 Section 52.1486 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... strategy: Hydrocarbons and ozone. (a) The requirements of subpart G of this chapter are not met since...

  5. 40 CFR 52.1486 - Control strategy: Hydrocarbons and ozone.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Hydrocarbons and ozone. 52.1486 Section 52.1486 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... strategy: Hydrocarbons and ozone. (a) The requirements of subpart G of this chapter are not met since...

  6. 40 CFR 52.1486 - Control strategy: Hydrocarbons and ozone.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Hydrocarbons and ozone. 52.1486 Section 52.1486 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... strategy: Hydrocarbons and ozone. (a) The requirements of subpart G of this chapter are not met since...

  7. 40 CFR 52.2125 - Control strategy: Ozone.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... for the 1997 8-hour ozone NAAQS. This determination, in accordance with 40 CFR 51.918, suspends the... 40 Protection of Environment 5 2013-07-01 2013-07-01 false Control strategy: Ozone. 52.2125... strategy: Ozone. (a) Determination of attaining data. EPA has determined, as of November 15, 2011, the...

  8. 40 CFR 52.1779 - Control strategy: Ozone.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... for the 1997 8-hour ozone NAAQS. This determination, in accordance with 40 CFR 51.918, suspends the... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Ozone. 52.1779... strategy: Ozone. (a) Determination of attaining data. EPA has determined, as of November 15, 2011, the...

  9. 40 CFR 52.2125 - Control strategy: Ozone.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... for the 1997 8-hour ozone NAAQS. This determination, in accordance with 40 CFR 51.918, suspends the... 40 Protection of Environment 5 2014-07-01 2014-07-01 false Control strategy: Ozone. 52.2125... strategy: Ozone. (a) Determination of attaining data. EPA has determined, as of November 15, 2011, the...

  10. 40 CFR 52.2125 - Control strategy: Ozone.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... for the 1997 8-hour ozone NAAQS. This determination, in accordance with 40 CFR 51.918, suspends the... 40 Protection of Environment 5 2012-07-01 2012-07-01 false Control strategy: Ozone. 52.2125... strategy: Ozone. (a) Determination of attaining data. EPA has determined, as of November 15, 2011, the...

  11. 40 CFR 52.2235 - Control strategy: Ozone.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... This determination, in accordance with 40 CFR 51.918, suspends the requirements for this area to submit... 40 Protection of Environment 5 2012-07-01 2012-07-01 false Control strategy: Ozone. 52.2235... strategy: Ozone. (a) Determination—EPA is determining that, as of August 8, 1995, the Nashville...

  12. 40 CFR 52.2235 - Control strategy: Ozone.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    .... This determination, in accordance with 40 CFR 51.918, suspends the requirements for this area to submit... 40 Protection of Environment 5 2014-07-01 2014-07-01 false Control strategy: Ozone. 52.2235... strategy: Ozone. (a) Determination—EPA is determining that, as of August 8, 1995, the Nashville...

  13. 40 CFR 52.1779 - Control strategy: Ozone.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... for the 1997 8-hour ozone NAAQS. This determination, in accordance with 40 CFR 51.918, suspends the... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Ozone. 52.1779... strategy: Ozone. (a) Determination of attaining data. EPA has determined, as of November 15, 2011, the...

  14. 40 CFR 52.2235 - Control strategy: Ozone.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... This determination, in accordance with 40 CFR 51.918, suspends the requirements for this area to submit... 40 Protection of Environment 5 2013-07-01 2013-07-01 false Control strategy: Ozone. 52.2235... strategy: Ozone. (a) Determination—EPA is determining that, as of August 8, 1995, the Nashville...

  15. 40 CFR 52.1779 - Control strategy: Ozone.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... for the 1997 8-hour ozone NAAQS. This determination, in accordance with 40 CFR 51.918, suspends the... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Ozone. 52.1779... strategy: Ozone. (a) Determination of attaining data. EPA has determined, as of November 15, 2011, the...

  16. 40 CFR 52.2235 - Control strategy: Ozone.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... This determination, in accordance with 40 CFR 51.918, suspends the requirements for this area to submit... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Ozone. 52.2235... strategy: Ozone. (a) Determination—EPA is determining that, as of August 8, 1995, the Nashville...

  17. 40 CFR 52.2088 - Control strategy: Ozone.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the provisions of EPA's ozone implementation rule (see 40 CFR 51.918), this determination suspends the... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Ozone. 52.2088... strategy: Ozone. (a) Revisions to the State Implementation Plan submitted by the Rhode Island Department...

  18. 40 CFR 52.2235 - Control strategy: Ozone.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Ozone. 52.2235... strategy: Ozone. (a) Determination—EPA is determining that, as of August 8, 1995, the Nashville ozone nonattainment area has attained the ozone standard and that the reasonable further progress and...

  19. 40 CFR 52.1476 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Particulate matter... strategy: Particulate matter. (a) The requirements of subpart G of this chapter are not met since the plan does not provide for the attainment and maintenance of the national standards for particulate matter...

  20. 40 CFR 52.1880 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... NAAQS. These determinations, in accordance with 40 CFR 52.1004(c), suspend the requirements for these... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Particulate matter... strategy: Particulate matter. (a) The requirements of subpart G of this chapter are not met because...

  1. 40 CFR 52.1476 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Particulate matter... strategy: Particulate matter. (a) The requirements of subpart G of this chapter are not met since the plan does not provide for the attainment and maintenance of the national standards for particulate matter...

  2. 40 CFR 52.1476 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Particulate matter... strategy: Particulate matter. (a) The requirements of subpart G of this chapter are not met since the plan does not provide for the attainment and maintenance of the national standards for particulate matter...

  3. 40 CFR 52.1880 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... NAAQS. These determinations, in accordance with 40 CFR 52.1004(c), suspend the requirements for these... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Particulate matter... strategy: Particulate matter. (a) The requirements of subpart G of this chapter are not met because...

  4. 40 CFR 52.1476 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Particulate matter... strategy: Particulate matter. (a) The requirements of subpart G of this chapter are not met since the plan does not provide for the attainment and maintenance of the national standards for particulate matter...

  5. OPTIMIZATION OF INTEGRATED URBAN WET-WEATHER CONTROL STRATEGIES

    EPA Science Inventory

    An optimization method for urban wet weather control (WWC) strategies is presented. The developed optimization model can be used to determine the most cost-effective strategies for the combination of centralized storage-release systems and distributed on-site WWC alternatives. T...

  6. 40 CFR 52.2525 - Control strategy: Sulfur dioxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Sulfur dioxide. 52.2525 Section 52.2525 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... strategy: Sulfur dioxide. (a) The provisions of § 51.112(a) are not met because the State did...

  7. 40 CFR 52.2780 - Control strategy for sulfur oxides.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy for sulfur oxides. 52... strategy for sulfur oxides. (a) The requirements of subpart G of this chapter are not met since there has... maintenance of the national ambient air quality standards for sulfur oxides on the island of St. Croix....

  8. 40 CFR 52.2089 - Control strategy: carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 5 2012-07-01 2012-07-01 false Control strategy: carbon monoxide. 52... strategy: carbon monoxide. (a) Approval—On September 22, 2008, the Rhode Island Department of Environmental Management submitted a request to establish a limited maintenance plan for the Providence Rhode Island...

  9. 40 CFR 52.1581 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Carbon monoxide. 52... strategy: Carbon monoxide. (a) Approval—The September 28, 1995 revision to the carbon monoxide state... Quality Standard for carbon monoxide through the year 2007. (b) The base year carbon monoxide...

  10. 40 CFR 52.2089 - Control strategy: carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: carbon monoxide. 52... strategy: carbon monoxide. (a) Approval—On September 22, 2008, the Rhode Island Department of Environmental Management submitted a request to establish a limited maintenance plan for the Providence Rhode Island...

  11. 40 CFR 52.1132 - Control strategy: Carbon Monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Carbon Monoxide. 52... strategy: Carbon Monoxide. (a) Approval—On November 13, 1992, the Massachusetts Department of Environmental Protection submitted a revision to the carbon monoxide State Implementation Plan for the 1990 base...

  12. 40 CFR 52.1528 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Carbon monoxide. 52... strategy: Carbon monoxide. (a) Approval—On February 1, 1999, the New Hampshire Department of Environmental... program for carbon monoxide that ceased operating on January 1, 1995. The Nashua...

  13. 40 CFR 52.1237 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Carbon monoxide. 52... strategy: Carbon monoxide. (a) The base year carbon monoxide emission inventory requirement of section 187... Metropolitan Area and Minneapolis-St. Paul Metropolitan Area. (b) Approval—The 1993 carbon monoxide...

  14. 40 CFR 52.1581 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Carbon monoxide. 52... strategy: Carbon monoxide. (a) Approval—The September 28, 1995 revision to the carbon monoxide state... Quality Standard for carbon monoxide through the year 2007. (b) The base year carbon monoxide...

  15. 40 CFR 52.1528 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Carbon monoxide. 52... strategy: Carbon monoxide. (a) Approval—On February 1, 1999, the New Hampshire Department of Environmental... program for carbon monoxide that ceased operating on January 1, 1995. The Nashua...

  16. 40 CFR 52.1132 - Control strategy: Carbon Monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Carbon Monoxide. 52... strategy: Carbon Monoxide. (a) Approval—On November 13, 1992, the Massachusetts Department of Environmental Protection submitted a revision to the carbon monoxide State Implementation Plan for the 1990 base...

  17. 40 CFR 52.2089 - Control strategy: carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 5 2013-07-01 2013-07-01 false Control strategy: carbon monoxide. 52... strategy: carbon monoxide. (a) Approval—On September 22, 2008, the Rhode Island Department of Environmental Management submitted a request to establish a limited maintenance plan for the Providence Rhode Island...

  18. 40 CFR 52.1237 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Carbon monoxide. 52... strategy: Carbon monoxide. (a) The base year carbon monoxide emission inventory requirement of section 187... Metropolitan Area and Minneapolis-St. Paul Metropolitan Area. (b) Approval—The 1993 carbon monoxide...

  19. 40 CFR 52.1528 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Carbon monoxide. 52... strategy: Carbon monoxide. (a) Approval—On February 1, 1999, the New Hampshire Department of Environmental... program for carbon monoxide that ceased operating on January 1, 1995. The Nashua...

  20. 40 CFR 52.1237 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Carbon monoxide. 52... strategy: Carbon monoxide. (a) The base year carbon monoxide emission inventory requirement of section 187... Metropolitan Area and Minneapolis-St. Paul Metropolitan Area. (b) Approval—The 1993 carbon monoxide...

  1. 40 CFR 52.1132 - Control strategy: Carbon Monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Carbon Monoxide. 52... strategy: Carbon Monoxide. (a) Approval—On November 13, 1992, the Massachusetts Department of Environmental Protection submitted a revision to the carbon monoxide State Implementation Plan for the 1990 base...

  2. 40 CFR 52.1237 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Carbon monoxide. 52... strategy: Carbon monoxide. (a) The base year carbon monoxide emission inventory requirement of section 187... Metropolitan Area and Minneapolis-St. Paul Metropolitan Area. (b) Approval—The 1993 carbon monoxide...

  3. 40 CFR 52.2089 - Control strategy: carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: carbon monoxide. 52... strategy: carbon monoxide. (a) Approval—On September 22, 2008, the Rhode Island Department of Environmental Management submitted a request to establish a limited maintenance plan for the Providence Rhode Island...

  4. 40 CFR 52.1132 - Control strategy: Carbon Monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Carbon Monoxide. 52... strategy: Carbon Monoxide. (a) Approval—On November 13, 1992, the Massachusetts Department of Environmental Protection submitted a revision to the carbon monoxide State Implementation Plan for the 1990 base...

  5. 40 CFR 52.1581 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Carbon monoxide. 52... strategy: Carbon monoxide. (a) Approval—The September 28, 1995 revision to the carbon monoxide state... Quality Standard for carbon monoxide through the year 2007. (b) The base year carbon monoxide...

  6. 40 CFR 52.1528 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Carbon monoxide. 52... strategy: Carbon monoxide. (a) Approval—On February 1, 1999, the New Hampshire Department of Environmental... program for carbon monoxide that ceased operating on January 1, 1995. The Nashua...

  7. 40 CFR 52.1237 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Carbon monoxide. 52... strategy: Carbon monoxide. (a) The base year carbon monoxide emission inventory requirement of section 187... Metropolitan Area and Minneapolis-St. Paul Metropolitan Area. (b) Approval—The 1993 carbon monoxide...

  8. 40 CFR 52.2089 - Control strategy: carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 5 2014-07-01 2014-07-01 false Control strategy: carbon monoxide. 52... strategy: carbon monoxide. (a) Approval—On September 22, 2008, the Rhode Island Department of Environmental Management submitted a request to establish a limited maintenance plan for the Providence Rhode Island...

  9. 40 CFR 52.1581 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Carbon monoxide. 52... strategy: Carbon monoxide. (a) Approval—The September 28, 1995 revision to the carbon monoxide state... Quality Standard for carbon monoxide through the year 2007. (b) The base year carbon monoxide...

  10. 40 CFR 52.1528 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Carbon monoxide. 52... strategy: Carbon monoxide. (a) Approval—On February 1, 1999, the New Hampshire Department of Environmental... program for carbon monoxide that ceased operating on January 1, 1995. The Nashua...

  11. 40 CFR 52.1581 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Carbon monoxide. 52... strategy: Carbon monoxide. (a) Approval—The September 28, 1995 revision to the carbon monoxide state... Quality Standard for carbon monoxide through the year 2007. (b) The base year carbon monoxide...

  12. 40 CFR 52.1132 - Control strategy: Carbon Monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Carbon Monoxide. 52... strategy: Carbon Monoxide. (a) Approval—On November 13, 1992, the Massachusetts Department of Environmental Protection submitted a revision to the carbon monoxide State Implementation Plan for the 1990 base...

  13. 40 CFR 52.2780 - Control strategy for sulfur oxides.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 5 2014-07-01 2014-07-01 false Control strategy for sulfur oxides. 52... strategy for sulfur oxides. (a) The requirements of subpart G of this chapter are not met since there has... maintenance of the national ambient air quality standards for sulfur oxides on the island of St. Croix....

  14. 40 CFR 52.2780 - Control strategy for sulfur oxides.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 5 2012-07-01 2012-07-01 false Control strategy for sulfur oxides. 52... strategy for sulfur oxides. (a) The requirements of subpart G of this chapter are not met since there has... maintenance of the national ambient air quality standards for sulfur oxides on the island of St. Croix....

  15. 40 CFR 52.2780 - Control strategy for sulfur oxides.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 5 2013-07-01 2013-07-01 false Control strategy for sulfur oxides. 52... strategy for sulfur oxides. (a) The requirements of subpart G of this chapter are not met since there has... maintenance of the national ambient air quality standards for sulfur oxides on the island of St. Croix....

  16. 40 CFR 52.2780 - Control strategy for sulfur oxides.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy for sulfur oxides. 52... strategy for sulfur oxides. (a) The requirements of subpart G of this chapter are not met since there has... maintenance of the national ambient air quality standards for sulfur oxides on the island of St. Croix....

  17. 40 CFR 52.2525 - Control strategy: Sulfur dioxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Sulfur dioxide. 52.2525 Section 52.2525 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... strategy: Sulfur dioxide. (a) The provisions of § 51.112(a) are not met because the State did...

  18. 40 CFR 52.2525 - Control strategy: Sulfur dioxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 5 2012-07-01 2012-07-01 false Control strategy: Sulfur dioxide. 52.2525 Section 52.2525 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... strategy: Sulfur dioxide. (a) The provisions of § 51.112(a) are not met because the State did...

  19. 40 CFR 52.2033 - Control strategy: Sulfur oxides.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 5 2014-07-01 2014-07-01 false Control strategy: Sulfur oxides. 52.2033 Section 52.2033 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... strategy: Sulfur oxides. (a) (b) EPA approves the attainment demonstration State Implementation Plan...

  20. 40 CFR 52.2525 - Control strategy: Sulfur dioxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 5 2014-07-01 2014-07-01 false Control strategy: Sulfur dioxide. 52.2525 Section 52.2525 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... strategy: Sulfur dioxide. (a) (b) EPA approves the attainment demonstration State Implementation Plan...

  1. 40 CFR 52.1576 - Control strategy: Nitrogen dioxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Nitrogen dioxide. 52... strategy: Nitrogen dioxide. (a) The requirements of § 52.14(c)(3) of this chapter as of May 8, 1974 (39 FR 16346), are not met since the plan does not provide for the degree of nitrogen oxides emission...

  2. 40 CFR 52.2275 - Control strategy and regulations: Ozone.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 5 2014-07-01 2014-07-01 false Control strategy and regulations: Ozone... strategy and regulations: Ozone. (a) Section 510.3 of revised Regulation V, which was submitted by the... accordance with the schedule set forth below. (c)(1) Removal from service of a 12,000 BPD vacuum...

  3. 40 CFR 52.2275 - Control strategy and regulations: Ozone.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 5 2012-07-01 2012-07-01 false Control strategy and regulations: Ozone... strategy and regulations: Ozone. (a) Section 510.3 of revised Regulation V, which was submitted by the... accordance with the schedule set forth below. (c)(1) Removal from service of a 12,000 BPD vacuum...

  4. 40 CFR 52.2275 - Control strategy and regulations: Ozone.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy and regulations: Ozone... strategy and regulations: Ozone. (a) Section 510.3 of revised Regulation V, which was submitted by the... accordance with the schedule set forth below. (c)(1) Removal from service of a 12,000 BPD vacuum...

  5. 40 CFR 52.1534 - Control strategy: Ozone.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... implementation rule (see 40 CFR 51.918), this determination suspends the reasonable further progress and... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Ozone. 52.1534... strategy: Ozone. (a) Revisions to the State Implementation Plan submitted by the New Hampshire...

  6. 40 CFR 52.2275 - Control strategy and regulations: Ozone.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 5 2013-07-01 2013-07-01 false Control strategy and regulations: Ozone... strategy and regulations: Ozone. (a) Section 510.3 of revised Regulation V, which was submitted by the... accordance with the schedule set forth below. (c)(1) Removal from service of a 12,000 BPD vacuum...

  7. 40 CFR 52.2275 - Control strategy and regulations: Ozone.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy and regulations: Ozone... strategy and regulations: Ozone. (a) Section 510.3 of revised Regulation V, which was submitted by the... accordance with the schedule set forth below. (c)(1) Removal from service of a 12,000 BPD vacuum...

  8. A nonlinear strategy for sensor based vehicle path control

    NASA Technical Reports Server (NTRS)

    Mayr, R.

    1994-01-01

    A method of transverse control which makes use of nonlinear formulations is presented. The strategy is utilized to stabilize a vehicle. The vehicle is autonomously guided and takes its control inputs from an optical sensing system. Additionally, the velocity of the vehicle is dictated by a longitudinal controller, which is also discussed.

  9. The Myriad Strategies for Seeking Control in the Dying Process

    ERIC Educational Resources Information Center

    Schroepfer, Tracy A.; Noh, Hyunjin; Kavanaugh, Melinda

    2009-01-01

    Purpose: This study explored the role control plays in the dying process of terminally ill elders by investigating the aspects of the dying process over which they seek to exercise control, the strategies they use, and whether they desire to exercise more control. Design and Methods: In-depth face-to-face interviews were conducted with 84…

  10. Dynamic Analysis of Nuclear Energy System Strategies

    SciTech Connect

    Den Durpel, Luc Van

    2004-06-17

    DANESS is an integrated process model for nuclear energy systems allowing the simulation of multiple reactors and fuel cycles in a continuously changing nuclear reactor park configuration. The model is energy demand driven and simulates all nuclear fuel cycle facilites, up to 10 reactors and fuels. Reactor and fuel cycle facility history are traced and the cost of generating energy is calculated per reactor and for total nuclear energy system. The DANESS model aims at performing dynamic systems analysis of nuclear energy development used for integrated analysis of development paths for nuclear energy, parameter scoping for new nuclear energy systems, economic analysis of nuclear energy, government role analysis, and education.

  11. 40 CFR 52.1877 - Control strategy: Photochemical oxidants (hydrocarbons).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... oxidants (hydrocarbons). 52.1877 Section 52.1877 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY....1877 Control strategy: Photochemical oxidants (hydrocarbons). (a) The requirements of Subpart G of this... national standard for photochemical oxidants (hydrocarbons) in the Metropolitan Cincinnati...

  12. 40 CFR 52.1877 - Control strategy: Photochemical oxidants (hydrocarbons).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... oxidants (hydrocarbons). 52.1877 Section 52.1877 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY....1877 Control strategy: Photochemical oxidants (hydrocarbons). (a) The requirements of Subpart G of this... national standard for photochemical oxidants (hydrocarbons) in the Metropolitan Cincinnati...

  13. 40 CFR 52.1877 - Control strategy: Photochemical oxidants (hydrocarbons).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... oxidants (hydrocarbons). 52.1877 Section 52.1877 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY....1877 Control strategy: Photochemical oxidants (hydrocarbons). (a) The requirements of Subpart G of this... national standard for photochemical oxidants (hydrocarbons) in the Metropolitan Cincinnati...

  14. 40 CFR 52.1877 - Control strategy: Photochemical oxidants (hydrocarbons).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... oxidants (hydrocarbons). 52.1877 Section 52.1877 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY....1877 Control strategy: Photochemical oxidants (hydrocarbons). (a) The requirements of Subpart G of this... national standard for photochemical oxidants (hydrocarbons) in the Metropolitan Cincinnati...

  15. 40 CFR 52.1877 - Control strategy: Photochemical oxidants (hydrocarbons).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... oxidants (hydrocarbons). 52.1877 Section 52.1877 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY....1877 Control strategy: Photochemical oxidants (hydrocarbons). (a) The requirements of Subpart G of this... national standard for photochemical oxidants (hydrocarbons) in the Metropolitan Cincinnati...

  16. 40 CFR 52.573 - Control strategy: General.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Georgia § 52.573 Control strategy: General. The generic rules and procedures for emission trades (bubbles), submitted on October 27, 1982, by the...

  17. 40 CFR 52.573 - Control strategy: General.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Georgia § 52.573 Control strategy: General. The generic rules and procedures for emission trades (bubbles), submitted on October 27, 1982, by the...

  18. 40 CFR 52.573 - Control strategy: General.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Georgia> § 52.573 Control strategy: General... Georgia Department of Natural Resources, are disapproved because they do not meet the requirements of...

  19. 40 CFR 52.573 - Control strategy: General.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Georgia § 52.573 Control strategy: General. The generic rules and procedures for emission trades (bubbles), submitted on October 27, 1982, by the...

  20. Optimal control strategies for coupled quantum dots

    NASA Astrophysics Data System (ADS)

    Räsänen, Esa; Putaja, Antti; Mardoukhi, Yousof

    2013-09-01

    Semiconductor quantum dots are ideal candidates for quantum information applications in solid-state technology. However, advanced theoretical and experimental tools are required to coherently control, for example, the electronic charge in these systems. Here we demonstrate how quantum optimal control theory provides a powerful way to manipulate the electronic structure of coupled quantum dots with an extremely high fidelity. As alternative control fields we apply both laser pulses as well as electric gates, respectively. We focus on double and triple quantum dots containing a single electron or two electrons interacting via Coulomb repulsion. In the two-electron situation we also briefly demonstrate the challenges of timedependent density-functional theory within the adiabatic local-density approximation to produce comparable results with the numerically exact approach.

  1. Control strategies and algorithms for large astronomical optical telescope

    NASA Astrophysics Data System (ADS)

    Yang, Shihai

    2010-07-01

    This paper gives a summary on control strategies and algorithms for contemporary large astronomical optical telescopes. The study lays emphasis on high precision tracking for large astronomical optical telescopes with large inertia, ultra-low speed and multi-disturbance. The control strategies and algorithms of some telescopes based on direct drive or friction drive are analyzed carefully. Finally, the future development in this field is presented.

  2. Control strategies for yellow nutsedge and nightshade

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Yellow nutsedge is a perennial weed that is difficult to control in several crops once established. It is particularly problematic in onion production. Yellow nutsedge reproduces and is dispersed primarily by tubers that are formed at the apical ends of underground rhizomes. Tubers may remain viable...

  3. Abnormal Web Usage Control by Proxy Strategies.

    ERIC Educational Resources Information Center

    Yu, Hsiang-Fu; Tseng, Li-Ming

    2002-01-01

    Approaches to designing a proxy server with Web usage control and to making the proxy server effective on local area networks are proposed to prevent abnormal Web access and to prioritize Web usage. A system is implemented to demonstrate the approaches. The implementation reveals that the proposed approaches are effective, such that the abnormal…

  4. CHOOSING OPTIMUM FINANCIAL STRATEGIES: POLLUTION CONTROL SYSTEMS

    EPA Science Inventory

    The report alerts decision makers to qualifications for and availability of financial assistance from federal, state and local governments, and illustrates that it is well worth the time to analyze the special methods of financing pollution control expenditures and the available ...

  5. OPTIMAL COST CONTROL STRATEGIES FOR ATTACHED ALGAE

    EPA Science Inventory

    This paper presents a cost-benefit analysis for alternative programs intended for the control of the nuisance growth of an attached alga (Cladophora). Such analyses require that changes in water quality be quantitatively related to the cost of implementation for specific manageme...

  6. Control Strategies and Social Face in Conflict.

    ERIC Educational Resources Information Center

    Tjosvold, Dean

    This study explores the effects of controlling influence attempts on social face and constructive conflict resolution. It also investigates the role of social face in how persons respond to evaluations by their peers. A sample of 90 college undergraduates randomly assigned to six conditions. The group's evaluation of the representative's relative…

  7. Synthesis of nonlinear control strategies from fuzzy logic control algorithms

    NASA Technical Reports Server (NTRS)

    Langari, Reza

    1993-01-01

    Fuzzy control has been recognized as an alternative to conventional control techniques in situations where the plant model is not sufficiently well known to warrant the application of conventional control techniques. Precisely what fuzzy control does and how it does what it does is not quite clear, however. This important issue is discussed and in particular it is shown how a given fuzzy control scheme can resolve into a nonlinear control law and that in those situations the success of fuzzy control hinges on its ability to compensate for nonlinearities in plant dynamics.

  8. Flight testing TECS - The Total Energy Control System

    NASA Technical Reports Server (NTRS)

    Kelly, James R.; Person, Lee H., Jr.; Bruce, Kevin R.

    1986-01-01

    This paper describes some of the unique features of an integrated throttle-elevator control law known as the Total Energy Control System (TECS) which has been flight tested on NASA Langley's Transport Systems Research Vehicle. The TECS concept is designed around total energy principles. It utilizes a full-time autothrottle to control the total energy of the aircraft and the elevator to distribute the energy between speed and flight path objectives. Time histories of selected parameters generated from flight data are used to illustrate the pilot-like control strategy of the system and the priority logic employed when throttle limiting is encountered.

  9. Unique strategies to control reproduction in camels.

    PubMed

    Skidmore, J A; Morton, K M; Billah, M

    2010-01-01

    The reproductive efficiency of camels is low under natural pastural conditions and so the use of artifical insemination and embryo transfer are becoming increasingly important to improve their breeding potential. Methods to control their reproductive cycle are therefore essential. This review describes characteristics of the ovarian follicular wave pattern in camels and exogenous hormonal control of ovulation. It also summarizes the difficulties involved with artifical insemination and analyzing the highly gelatinous semen, and reports on the latest methods used to try and reduce the viscosity and liquefy camel semen. In addition an account is given of different hormonal and physical methods used to synchronise follicular waves, and various hormone treatments used to broaden the availability of ovulated, asynchronous and non-ovulated recipients are discussed. PMID:21755692

  10. Flight penetration of wind shear: Control strategies

    NASA Technical Reports Server (NTRS)

    Joshi, Amit S.

    1988-01-01

    Wind shear is a dangerous condition where there is a sharp change in the direction and magnitude of the wind velocity over a short distance or time. This condition is especially dangerous to aircraft during landing and takeoff and can cause a sudden loss of lift and thereby height at a critical time. A numerical simulation showed the effective performance of the Linear Quadratic Regulator and the Nonlinear Inverse Dynamics controllers. The major conclusions are listed and discussed.

  11. Energy scaling and reduction in controlling complex networks

    PubMed Central

    Chen, Yu-Zhong; Wang, Le-Zhi; Wang, Wen-Xu; Lai, Ying-Cheng

    2016-01-01

    Recent works revealed that the energy required to control a complex network depends on the number of driving signals and the energy distribution follows an algebraic scaling law. If one implements control using a small number of drivers, e.g. as determined by the structural controllability theory, there is a high probability that the energy will diverge. We develop a physical theory to explain the scaling behaviour through identification of the fundamental structural elements, the longest control chains (LCCs), that dominate the control energy. Based on the LCCs, we articulate a strategy to drastically reduce the control energy (e.g. in a large number of real-world networks). Owing to their structural nature, the LCCs may shed light on energy issues associated with control of nonlinear dynamical networks. PMID:27152220

  12. Energy scaling and reduction in controlling complex networks.

    PubMed

    Chen, Yu-Zhong; Wang, Le-Zhi; Wang, Wen-Xu; Lai, Ying-Cheng

    2016-04-01

    Recent works revealed that the energy required to control a complex network depends on the number of driving signals and the energy distribution follows an algebraic scaling law. If one implements control using a small number of drivers, e.g. as determined by the structural controllability theory, there is a high probability that the energy will diverge. We develop a physical theory to explain the scaling behaviour through identification of the fundamental structural elements, the longest control chains (LCCs), that dominate the control energy. Based on the LCCs, we articulate a strategy to drastically reduce the control energy (e.g. in a large number of real-world networks). Owing to their structural nature, the LCCs may shed light on energy issues associated with control of nonlinear dynamical networks. PMID:27152220

  13. Dynamic Analysis of Nuclear Energy System Strategies

    Energy Science and Technology Software Center (ESTSC)

    2004-06-17

    DANESS is an integrated process model for nuclear energy systems allowing the simulation of multiple reactors and fuel cycles in a continuously changing nuclear reactor park configuration. The model is energy demand driven and simulates all nuclear fuel cycle facilites, up to 10 reactors and fuels. Reactor and fuel cycle facility history are traced and the cost of generating energy is calculated per reactor and for total nuclear energy system. The DANESS model aims atmore » performing dynamic systems analysis of nuclear energy development used for integrated analysis of development paths for nuclear energy, parameter scoping for new nuclear energy systems, economic analysis of nuclear energy, government role analysis, and education.« less

  14. Energy Demands and Efficiency Strategies in Data Center Buildings

    SciTech Connect

    Shehabi, Arman

    2009-09-01

    for office or residential buildings. Estimates using a material-balance model match well with empirical results, indicating that the dominant particle sources and losses -- ventilation and filtration -- have been characterized. Measurements taken at a data center using economizers show nearly an order of magnitude increase in particle concentration during economizer activity. However, even with the increase, themeasured particle concentrations are still below concentration limits recommended in most industry standards. The research proceeds by exploring the feasibility of using economizers in data centers while simultaneously controlling particle concentrations with high-quality air filtration. Physical and chemical properties of indoor and outdoor particles were analyzed at a data center using economizers and varying levels of air filtration efficiency. Results show that when improved filtration is used in combination with an economizer, the indoor/outdoor concentration ratios for most measured particle types were similar to the measurements when using conventional filtration without economizers. An energy analysis of the data center reveals that, even during the summer months, chiller savings from economizer use greatly outweigh the increase in fan power associated with improved filtration. These findings indicate that economizer use combined with improved filtration couldsignificantly reduce data center energy demand while providing a level of protection from particles of outdoor origin similar to that observed with conventional design. The emphasis of the dissertation then shifts to evaluate the energy benefits of economizer use in data centers under different design strategies. Economizer use with high ventilation rates is compared against an alternative, water-side economizer design that does not affect indoor particle concentrations. Building energy models are employed to estimate energy savings of both economizer designs for data centers in

  15. Energy, industry and nitrogen: strategies for decreasing reactive nitrogen emissions.

    PubMed

    Moomaw, William R

    2002-03-01

    Nitrogen oxides are released during atmospheric combustion of fossil fuels and biomass, and during the production of certain chemicals and products. They can react with natural or man-made volatile organic compounds to produce smog, or else can be further oxidized to produce particulate haze, or acid rain that can eutrophy land and water. The reactive nitrogen that begins in the energy sector thus cascades through the atmosphere, the hydrosphere and soils before being eventually partially denitrifed to the global warming and stratospheric ozone-depleting gas nitrous oxide or molecular nitrogen. This paper will suggest how an economic analysis of the nitrogen cycle can identify the most cost-effective places to intervene. Nitrogen oxides released during fossil-fuel combustion in vehicles, power plants and heating boilers can either be controlled by add-on emission control technology, or can be eliminated by many of the same technical options that lead to carbon dioxide reduction. These integrated strategies also address sustainability, economic development and national security issues. Similarly in industrial production, it is more effective to focus on redesigning industrial processes rather than on nitrogen oxide pollution elimination from the current system. This paper will suggest which strategies might be utilized to address multiple benefits rather than focusing on single pollutants. PMID:12078008

  16. Guidance and control strategies for aerospace vehicles

    NASA Technical Reports Server (NTRS)

    Hibey, Joseph L.; Naidu, D. S.

    1987-01-01

    A simplified method of matched asymptotic expansions was developed where the common part in composite solution is generated as a polynomial in stretched variable instead of actually evaluating the same from the outer solution. This methodology was applied to the solution of the exact equations for three dimensional atmospheric entry problems. Compared to previous works, the present simplified methodology yields explicit analytical expressions for various components of the composite solution without resorting to any type of transcendental equations to be solved only by numerical methods. The optimal control problem arising in the noncoplanar orbital transfer employing aeroassist was also addressed.

  17. Guidance and control strategies for aerospace vehicles

    NASA Technical Reports Server (NTRS)

    Naidu, Desineni S.; Hibey, Joseph L.

    1988-01-01

    The optimal control problem arising in coplanar, orbital transfer employing aeroassist technology is addressed. The maneuver involves the transfer from high Earth orbit to low Earth orbit. A performance index is chosen the minimize the fuel consumpltion for the transfer. Simulations are carried out for establishing a corridor of entry conditions which are suitable for flying the spacecraft through the atmosphere. A highlight of the paper is the application of an efficient multiple shooting method for taming the notorious nonlinear, two-point, boundary value problem resulting from optimization procedure.

  18. Attention, intention, and strategy in preparatory control

    PubMed Central

    Ruge, Hannes; Braver, Todd; Meiran, Nachshon

    2009-01-01

    The neural mechanisms underlying different forms of preparatory control were examined using event-related fMRI. Preparatory brain activation was monitored in relation to different types of advance information: (1) random task cues indicating which of two possible tasks to perform upon subsequent target presentation, (2) task-ambiguous target stimuli, or 3) targets for which the correct response could be pre-determined. Three types of activation pattern were observed in different brain regions. First, more posterior regions of lateral prefrontal cortex (LPFC) and parietal cortex were activated by both advance task cues and advance targets, but with increased and more sustained activation for the latter. Second, more anterior regions of LPFC and parietal cortex were selectively activated by advance targets. Importantly, in these regions preparatory activation was not further modulated by the availability of advance response information. In contrast, preparatory activation in a third set of brain regions, including medial frontal cortex, reflected the utilization of advance response information, but by only a subset of participants. These results suggest three types of preparatory control: attentional (stimulus-oriented), intentional (action-oriented), and a possibly strategic component that might determine inter-individual differences in response readiness. Notably, the absence of regions selectively or even preferentially activated during cue-based preparation argues against certain conceptualizations of task-selective attention under cued task switching conditions. PMID:19397862

  19. Research of Energy Substitution Strategy of China

    NASA Astrophysics Data System (ADS)

    Zhang, Lifeng; kai, Chen

    For a long time, China's energy endowment structure determines the production structure and consumption structure of energy are coal-based.This situation is difficult to change for quite a long time. With the rapid economic growth, industrialization and urbanization, the demand for energy, especially for oil, natural gas will continue to increase. But the oil and gas supply can not meet the needs of rapid growth. The most direct way is to import, and imports will be charged by the international energy situation, and will affect energy and economic security. In view of our country abundant coal resources, we can consider to use coal substituting oil and natural gas to reduce dependence on foreign energy, to strengthen energy and economic security. Therefore, using translog production function, the text forecasts substitution elasticity and the marginal substitution rate between the capital, coal, oil and natural gas, and puts forward substitution program.

  20. Topographical strategies to control neural outgrowth.

    PubMed

    Roccasalvo, I Morana; Sergi, P N; Tonazzini, I; Cecchini, M; Micera, S

    2015-08-01

    In this work a synergistic approach is used to investigate how directional anisotropic surfaces (i.e., nanogratings) control the alignment of PC12 neurites. Finite Element models were used to assess the distribution of stresses in non-spread growth cones and filopodia. The stress field was assumed to be the main triggering cause fostering the increase and stabilization of filopodia, so the local stress maxima were directly related to the neuritic orientation. Moreover, a computational framework was implemented within an open source Java environment (CX3D), and in silico simulations were carried out to reproduce and predict biological experiments. No significant differences were found between biological experiments and in silico simulations (alignment angle, p = 0.4685; tortuosity, p = 0.9075) with a standard level of confidence (95%). PMID:26737940

  1. Control strategy for cooperating disparate manipulators

    NASA Technical Reports Server (NTRS)

    Lew, Jae Young

    1989-01-01

    To manipulate large payloads typical of space construction, the concept of a small arm mounted on the end of a large arm is introduced. The main purposes of such a configuration are to increase the structural stiffness of the robot by bracing against or locking to a stationary frame, and to maintain a firm position constraint between the robot's base and workpieces by grasping them. Possible topologies for a combination of disparate large and small arms are discussed, and kinematics, dynamics, controls, and coordination of the two arms, especially when they brace at the tip of the small arm, are developed. The feasibility and improvement in performance are verified, not only with analytical work and simulation results but also with experiments on the existing arrangement Robotic Arm Large and Flexible and Small Articulated Manipulator.

  2. IMPACT OF POINT SOURCE CONTROL STRATEGIES ON NO2 LEVELS

    EPA Science Inventory

    The report gives final results of a study of the effect of two point source NOx control strategies in the Chicago Air Quality Control Region (AQCR): combustion modification and flue gas treatment. The study involved the dispersion modeling of essentially all point and area source...

  3. Practical control strategy eliminates FCCU compressor surge problems

    SciTech Connect

    Campos, M.C.M.M.; Rodriques, P.S.B. )

    1993-01-11

    This paper reports that the control system originally designed for the fluid catalytic cracking unit (FCCU) compressor at Petroleo Brasileiro SA's (Petrobras) Presidente Bernardes refinery, in Sao Paulo, Brazil, was inadequate. The system required almost permanent flow recirculation to prevent surge. An improved antisurge control strategy was implemented in mid-1990. Since then, the unit has operated without the former surge problems.

  4. Strategies for Control of Man-Made Eutrophication

    ERIC Educational Resources Information Center

    Grundy, Richard D.

    1971-01-01

    The key concerns for both long- and short-term control strategies for cultural eutrophication are: (1) controls which reflect the regional character of the problem, and (2) concern for the potential public health and environmental implications of the nonphosphate detergent formulations. (Author/CP)

  5. 40 CFR 52.1373 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Carbon monoxide. 52...: Carbon monoxide. (a) On July 8, 1997, the Governor of Montana submitted revisions to the SIP narrative for the Missoula carbon monoxide control plan. (b) Revisions to the Montana State Implementation...

  6. 40 CFR 52.1373 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Carbon monoxide. 52...: Carbon monoxide. (a) On July 8, 1997, the Governor of Montana submitted revisions to the SIP narrative for the Missoula carbon monoxide control plan. (b) Revisions to the Montana State Implementation...

  7. 40 CFR 52.1373 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Carbon monoxide. 52...: Carbon monoxide. (a) On July 8, 1997, the Governor of Montana submitted revisions to the SIP narrative for the Missoula carbon monoxide control plan. (b) Revisions to the Montana State Implementation...

  8. 40 CFR 52.1373 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Carbon monoxide. 52...: Carbon monoxide. (a) On July 8, 1997, the Governor of Montana submitted revisions to the SIP narrative for the Missoula carbon monoxide control plan. (b) Revisions to the Montana State Implementation...

  9. 40 CFR 52.1373 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Carbon monoxide. 52...: Carbon monoxide. (a) On July 8, 1997, the Governor of Montana submitted revisions to the SIP narrative for the Missoula carbon monoxide control plan. (b) Revisions to the Montana State Implementation...

  10. Wetting-controlled strategies: from theories to bio-inspiration.

    PubMed

    Song, Cheng; Zheng, Yongmei

    2014-08-01

    Creatures have evolved the unique wetting-controlled strategies on their surfaces to collect water for the sake of survival, such as Beetle back, spider silk and plant leaf as well, which inspires us to open the area of novel researches. In this feature article, we review the theoretical basis of wetting-controlling regarding of wettability and highlight the biological wetting-controlled strategies in water transport, and water collection, and also introduce some bio-inspired materials with water collection properties. It is significant to design the novel materials that would be used in the fields of responsive, smart catalysis, filtration and sensing besides water collection. PMID:24290249

  11. Innovative Energy Strategies for CO2 Stabilization

    NASA Astrophysics Data System (ADS)

    Watts, Robert G.

    2002-08-01

    Many of the world's climate scientists believe that the build-up of heat-trapping CO2 in the atmosphere will lead to global warming unless we burn less fossil fuels. At the same time, energy must be supplied in increasing amounts for the developing world to continue its growth. This work discusses the feasibility of increasingly efficient energy use and the potential for supplying energy from sources that do not introduce CO2. The book analyzes the prospects for Earth-based renewables: solar, wind, biomass, hydroelectricity, geothermal and ocean energy. It then discusses nuclear fission and fusion, and the relatively new idea of harvesting solar energy on satellites or lunar bases. It will be essential reading for all those interested in energy issues.

  12. U.S. Department of Energy - Critical Materials Strategy

    SciTech Connect

    2010-12-01

    The Critical Materials Strategy builds on the Department’s previous work in this area and provides a foundation for future action. This Strategy is a first step toward a comprehensive response to the challenges before us. We hope it will also encourage others to engage in a dialogue about these issues and work together to achieve our Nation’s clean energy goals.

  13. Design and testing of a control strategy for a large naturallyventilated office building

    SciTech Connect

    Carrilho da Graca, Guilherme; Linden, Paul F.; Haves, Philip

    2004-03-16

    The design for the new Federal Building for San Franciscoincludes an office tower that is to be naturally ventilated. Each flooris designed to be cross-ventilated, through upper windows that arecontrolled by the building management system (BMS). Users have controlover lower windows, which can be as much as 50 percent of the totalopenable area. There are significant differences in the performance andthe control of the windward and leeward sides of the building, andseparate monitoring and control strategies are determined for each side.The performance and control of the building has been designed and testedusing a modified version of EnergyPlus. Results from studies withEnergyPlus and CFD are used in designing the control strategy. EnergyPluswas extended to model a simplified version of the airflow patterndetermined using CFD. Wind-driven cross-ventilation produces a main jetthrough the upper openings of the building, across the ceiling from thewindward to the leeward side. Below this jet, the occupied regions aresubject to a recirculating air flow. Results show that temperatureswithin the building are predicted to be satisfactory, provided a suitablecontrol strategy is implemented uses night cooling in periods of hotweather. The control strategy has 10 window opening modes. EnergyPlus wasextended to simulate the effects of these modes, and to assess theeffects of different forms of user behavior. The results show how userbehavior can significantly influence the buildingperformance.

  14. Inhibitory control gains from higher-order cognitive strategy training.

    PubMed

    Motes, Michael A; Gamino, Jacquelyn F; Chapman, Sandra B; Rao, Neena K; Maguire, Mandy J; Brier, Matthew R; Kraut, Michael A; Hart, John

    2014-02-01

    The present study examined the transfer of higher-order cognitive strategy training to inhibitory control. Middle school students enrolled in a comprehension- and reasoning-focused cognitive strategy training program and passive controls participated. The training program taught students a set of steps for inferring essential gist or themes from materials. Both before and after training or a comparable duration in the case of the passive controls, participants completed a semantically cued Go/No-Go task that was designed to assess the effects of depth of semantic processing on response inhibition and components of event-related potentials (ERP) related to response inhibition. Depth of semantic processing was manipulated by varying the level of semantic categorization required for response selection and inhibition. The SMART-trained group showed inhibitory control gains and changes in fronto-central P3 ERP amplitudes on inhibition trials; whereas, the control group did not. The results provide evidence of the transfer of higher-order cognitive strategy training to inhibitory control and modulation of ERPs associated with semantically cued inhibitory control. The findings are discussed in terms of implications for cognitive strategy training, models of cognitive abilities, and education. PMID:24286804

  15. Energy management strategy based on fuzzy logic for a fuel cell hybrid bus

    NASA Astrophysics Data System (ADS)

    Gao, Dawei; Jin, Zhenhua; Lu, Qingchun

    Fuel cell vehicles, as a substitute for internal-combustion-engine vehicles, have become a research hotspot for most automobile manufacturers all over the world. Fuel cell systems have disadvantages, such as high cost, slow response and no regenerative energy recovery during braking; hybridization can be a solution to these drawbacks. This paper presents a fuel cell hybrid bus which is equipped with a fuel cell system and two energy storage devices, i.e., a battery and an ultracapacitor. An energy management strategy based on fuzzy logic, which is employed to control the power flow of the vehicular power train, is described. This strategy is capable of determining the desired output power of the fuel cell system, battery and ultracapacitor according to the propulsion power and recuperated braking power. Some tests to verify the strategy were developed, and the results of the tests show the effectiveness of the proposed energy management strategy and the good performance of the fuel cell hybrid bus.

  16. Control Strategies for the DAB Based PV Interface System

    PubMed Central

    El-Helw, Hadi M.; Al-Hasheem, Mohamed; Marei, Mostafa I.

    2016-01-01

    This paper presents an interface system based on the Dual Active Bridge (DAB) converter for Photovoltaic (PV) arrays. Two control strategies are proposed for the DAB converter to harvest the maximum power from the PV array. The first strategy is based on a simple PI controller to regulate the terminal PV voltage through the phase shift angle of the DAB converter. The Perturb and Observe (P&O) Maximum Power Point Tracking (MPPT) technique is utilized to set the reference of the PV terminal voltage. The second strategy presented in this paper employs the Artificial Neural Network (ANN) to directly set the phase shift angle of the DAB converter that results in harvesting maximum power. This feed-forward strategy overcomes the stability issues of the feedback strategy. The proposed PV interface systems are modeled and simulated using MATLAB/SIMULINK and the EMTDC/PSCAD software packages. The simulation results reveal accurate and fast response of the proposed systems. The dynamic performance of the proposed feed-forward strategy outdoes that of the feedback strategy in terms of accuracy and response time. Moreover, an experimental prototype is built to test and validate the proposed PV interface system. PMID:27560138

  17. Control Strategies for the DAB Based PV Interface System.

    PubMed

    El-Helw, Hadi M; Al-Hasheem, Mohamed; Marei, Mostafa I

    2016-01-01

    This paper presents an interface system based on the Dual Active Bridge (DAB) converter for Photovoltaic (PV) arrays. Two control strategies are proposed for the DAB converter to harvest the maximum power from the PV array. The first strategy is based on a simple PI controller to regulate the terminal PV voltage through the phase shift angle of the DAB converter. The Perturb and Observe (P&O) Maximum Power Point Tracking (MPPT) technique is utilized to set the reference of the PV terminal voltage. The second strategy presented in this paper employs the Artificial Neural Network (ANN) to directly set the phase shift angle of the DAB converter that results in harvesting maximum power. This feed-forward strategy overcomes the stability issues of the feedback strategy. The proposed PV interface systems are modeled and simulated using MATLAB/SIMULINK and the EMTDC/PSCAD software packages. The simulation results reveal accurate and fast response of the proposed systems. The dynamic performance of the proposed feed-forward strategy outdoes that of the feedback strategy in terms of accuracy and response time. Moreover, an experimental prototype is built to test and validate the proposed PV interface system. PMID:27560138

  18. Resurgent malaria at the millennium: control strategies in crisis.

    PubMed

    Baird, J K

    2000-04-01

    Completion of the Panama Canal in 1914 marked the beginning of an era of vector control that achieved conspicuous success against malaria. In 1955 the World Health Organization (WHO) adopted the controversial Global Eradication Campaign emphasising DDT (dichlorodiphenyltrichloroethane) spraying in homes. The incidence of malaria fell sharply where the programme was implemented, but the strategy was not applied in holoendemic Africa. This, along with the failure to achieve eradication in larger tropical regions, contributed to disillusionment with the policy. The World Health Assembly abandoned the eradication strategy in 1969. A resurgence of malaria began at about that time and today reaches into areas where eradication or control had been achieved. A global malaria crisis looms. In 1993 the WHO adopted a Global Malaria Control Strategy that placed priority in control of disease rather than infection. This formalises a policy that emphasises diagnosis and treatment in a primary healthcare setting, while de-emphasising spraying of residual insecticides. The new policy explicitly stresses malaria in Africa, but expresses the intent to bring control programmes around the world into line with the strategy. This review raises the argument that a global control strategy conceived to address the extraordinary malaria situation in Africa may not be suitable elsewhere. The basis of argument lies in the accomplishments of the Global Eradication Campaign viewed in an historical and geographical context. Resurgent malaria accompanying declining vector control activities in Asia and the Americas suggests that the abandonment of residual spraying may be premature given the tools now at hand. The inadequacy of vector control as the primary instrument of malaria control in holoendemic Africa does not preclude its utility in Asia and the Americas. PMID:10804031

  19. Optimal control strategy for abnormal innate immune response.

    PubMed

    Tan, Jinying; Zou, Xiufen

    2015-01-01

    Innate immune response plays an important role in control and clearance of pathogens following viral infection. However, in the majority of virus-infected individuals, the response is insufficient because viruses are known to use different evasion strategies to escape immune response. In this study, we use optimal control theory to investigate how to control the innate immune response. We present an optimal control model based on an ordinary-differential-equation system from a previous study, which investigated the dynamics and regulation of virus-triggered innate immune signaling pathways, and we prove the existence of a solution to the optimal control problem involving antiviral treatment or/and interferon therapy. We conduct numerical experiments to investigate the treatment effects of different control strategies through varying the cost function and control efficiency. The results show that a separate treatment, that is, only inhibiting viral replication (u1(t)) or enhancing interferon activity (u2(t)), has more advantages for controlling viral infection than a mixed treatment, that is, controlling both (u1(t)) and (u2(t)) simultaneously, including the smallest cost and operability. These findings would provide new insight for developing effective strategies for treatment of viral infectious diseases. PMID:25949271

  20. Energy's role in competitiveness: Context and strategy

    SciTech Connect

    Roop, J.M.

    1990-02-01

    This study of competitiveness has three objectives. The first objective is to explain how macroeconomic and microeconomic factors can affect structural change in the US economy and how energy is linked to these factors. The second objective is to provide an explanation of how many individual decision makers, in responding to higher energy prices, have changed the structure of the economy. This structural change, and the effect it has had on energy use, is estimated for the US economy. A major component of these changes results from changes in US trade with other countries, which gives rise to the third objective. The third objective is to develop a research design that will allow a better understanding of the role that energy plays in the competitiveness of goods in world trade. 30 refs., 11 figs., 5 tabs.

  1. High Level Waste (HLW) Feed Process Control Strategy

    SciTech Connect

    STAEHR, T.W.

    2000-06-14

    The primary purpose of this document is to describe the overall process control strategy for monitoring and controlling the functions associated with the Phase 1B high-level waste feed delivery. This document provides the basis for process monitoring and control functions and requirements needed throughput the double-shell tank system during Phase 1 high-level waste feed delivery. This document is intended to be used by (1) the developers of the future Process Control Plan and (2) the developers of the monitoring and control system.

  2. Modelling the control strategies against dengue in Singapore

    PubMed Central

    BURATTINI, M. N.; CHEN, M.; CHOW, A.; COUTINHO, F. A. B.; GOH, K. T.; LOPEZ, L. F.; MA, S.; MASSAD, E.

    2008-01-01

    SUMMARY Notified cases of dengue infections in Singapore reached historical highs in 2004 (9459 cases) and 2005 (13 817 cases) and the reason for such an increase is still to be established. We apply a mathematical model for dengue infection that takes into account the seasonal variation in incidence, characteristic of dengue fever, and which mimics the 2004–2005 epidemics in Singapore. We simulated a set of possible control strategies and confirmed the intuitive belief that killing adult mosquitoes is the most effective strategy to control an ongoing epidemic. On the other hand, the control of immature forms was very efficient in preventing the resurgence of dengue epidemics. Since the control of immature forms allows the reduction of adulticide, it seems that the best strategy is to combine both adulticide and larvicide control measures during an outbreak, followed by the maintenance of larvicide methods after the epidemic has subsided. In addition, the model showed that the mixed strategy of adulticide and larvicide methods introduced by the government seems to be very effective in reducing the number of cases in the first weeks after the start of control. PMID:17540051

  3. Tsetse Control and Gambian Sleeping Sickness; Implications for Control Strategy

    PubMed Central

    Kovacic, Vanja; Mangwiro, T. N. Clement; Vale, Glyn A.; Hastings, Ian; Solano, Philippe; Lehane, Michael J.; Torr, Steve J.

    2015-01-01

    Background Gambian sleeping sickness (human African trypanosomiasis, HAT) outbreaks are brought under control by case detection and treatment although it is recognised that this typically only reaches about 75% of the population. Vector control is capable of completely interrupting HAT transmission but is not used because it is considered too expensive and difficult to organise in resource-poor settings. We conducted a full scale field trial of a refined vector control technology to determine its utility in control of Gambian HAT. Methods and Findings The major vector of Gambian HAT is the tsetse fly Glossina fuscipes which lives in the humid zone immediately adjacent to water bodies. From a series of preliminary trials we determined the number of tiny targets required to reduce G. fuscipes populations by more than 90%. Using these data for model calibration we predicted we needed a target density of 20 per linear km of river in riverine savannah to achieve >90% tsetse control. We then carried out a full scale, 500 km2 field trial covering two HAT foci in Northern Uganda to determine the efficacy of tiny targets (overall target density 5.7/km2). In 12 months, tsetse populations declined by more than 90%. As a guide we used a published HAT transmission model and calculated that a 72% reduction in tsetse population is required to stop transmission in those settings. Interpretation The Ugandan census suggests population density in the HAT foci is approximately 500 per km2. The estimated cost for a single round of active case detection (excluding treatment), covering 80% of the population, is US$433,333 (WHO figures). One year of vector control organised within the country, which can completely stop HAT transmission, would cost US$42,700. The case for adding this method of vector control to case detection and treatment is strong. We outline how such a component could be organised. PMID:26267814

  4. Estimating costs of sea lice control strategy in Norway.

    PubMed

    Liu, Yajie; Bjelland, Hans Vanhauwaer

    2014-12-01

    This paper explores the costs of sea lice control strategies associated with salmon aquaculture at a farm level in Norway. Diseases can cause reduction in growth, low feed efficiency and market prices, increasing mortality rates, and expenditures on prevention and treatment measures. Aquaculture farms suffer the most direct and immediate economic losses from diseases. The goal of a control strategy is to minimize the total disease costs, including biological losses, and treatment costs while to maximize overall profit. Prevention and control strategies are required to eliminate or minimize the disease, while cost-effective disease control strategies at the fish farm level are designed to reduce the losses, and to enhance productivity and profitability. Thus, the goal can be achieved by integrating models of fish growth, sea lice dynamics and economic factors. A production function is first constructed to incorporate the effects of sea lice on production at a farm level, followed by a detailed cost analysis of several prevention and treatment strategies associated with sea lice in Norway. The results reveal that treatments are costly and treatment costs are very sensitive to treatment types used and timing of the treatment conducted. Applying treatment at an early growth stage is more economical than at a later stage. PMID:25443395

  5. Control Systems Cyber Security:Defense in Depth Strategies

    SciTech Connect

    David Kuipers; Mark Fabro

    2006-05-01

    Information infrastructures across many public and private domains share several common attributes regarding IT deployments and data communications. This is particularly true in the control systems domain. A majority of the systems use robust architectures to enhance business and reduce costs by increasing the integration of external, business, and control system networks. However, multi-network integration strategies often lead to vulnerabilities that greatly reduce the security of an organization, and can expose mission-critical control systems to cyber threats. This document provides guidance and direction for developing ‘defense-in-depth’ strategies for organizations that use control system networks while maintaining a multi-tier information architecture that requires: Maintenance of various field devices, telemetry collection, and/or industrial-level process systems Access to facilities via remote data link or modem Public facing services for customer or corporate operations A robust business environment that requires connections among the control system domain, the external Internet, and other peer organizations.

  6. Two-DOF precision platform for spacecraft thrust vector control: control strategies and simulations

    NASA Astrophysics Data System (ADS)

    Ma, Kougen; Ghasemi-Nejhad, Mehrdad N.

    2004-07-01

    This paper presents control strategies and simulations of a two-DOF precision platform as an adaptive thruster mount structure with precision positioning and active vibration suppression capabilities for thrust vector control of space satellites. First, the configuration of the two-DOF precision platform is introduced, which is an intelligent tripod with two in-plane rotational degrees of freedom for the top device-plate. Precision positioning of this platform is achieved using active members that extend or contract to tilt the top device-plate where the thruster is mounted. Kinematic analysis of the platform is then presented and followed by two control strategies; namely local control strategy and global control strategy. In the local control strategy, the motion of each active member is controlled locally according to the kinematical feature of the platform and the local sensor information to achieve the desired tilt of the top device-plate. In the global control strategy, the motion of each active member is adjusted according to the system level information from a tilt sensor. Fuzzy logic control is employed and the two control strategies are simulated and compared.

  7. THE CHOICE OF REAL-TIME CONTROL STRATEGY FOR COMBINED SEWER OVERFLOW CONTROL

    EPA Science Inventory

    This paper focuses on the strategies used to operate a collection system in real-time control (RTC) in order to optimize use of system capacity and to reduce the cost of long-term combined sewer overflow (CSO) control. Three RTC strategies were developed and analyzed based on the...

  8. Control strategies for underactuated neural ensembles driven by optogenetic stimulation

    PubMed Central

    Ching, ShiNung; Ritt, Jason T.

    2013-01-01

    Motivated by experiments employing optogenetic stimulation of cortical regions, we consider spike control strategies for ensembles of uncoupled integrate and fire neurons with a common conductance input. We construct strategies for control of spike patterns, that is, multineuron trains of action potentials, up to some maximal spike rate determined by the neural biophysics. We emphasize a constructive role for parameter heterogeneity, and find a simple rule for controllability in pairs of neurons. In particular, we determine parameters for which common drive is not limited to inducing synchronous spiking. For large ensembles, we determine how the number of controllable neurons varies with the number of observed (recorded) neurons, and what collateral spiking occurs in the full ensemble during control of the subensemble. While complete control of spiking in every neuron is not possible with a single input, we find that a degree of subensemble control is made possible by exploiting dynamical heterogeneity. As most available technologies for neural stimulation are underactuated, in the sense that the number of target neurons far exceeds the number of independent channels of stimulation, these results suggest partial control strategies that may be important in the development of sensory neuroprosthetics and other neurocontrol applications. PMID:23576956

  9. Control strategy for a dual-arm maneuverable space robot

    NASA Technical Reports Server (NTRS)

    Wang, P. K. C.

    1987-01-01

    A simple strategy for the attitude control and arm coordination of a maneuverable space robot with dual arms is proposed. The basic task for the robot consists of the placement of marked rigid solid objects with specified pairs of gripping points and a specified direction of approach for gripping. The strategy consists of three phases each of which involves only elementary rotational and translational collision-free maneuvers of the robot body. Control laws for these elementary maneuvers are derived by using a body-referenced dynamic model of the dual-arm robot.

  10. Analysis of Control Strategies for Aircraft Flight Upset Recovery

    NASA Technical Reports Server (NTRS)

    Crespo, Luis G.; Kenny, Sean P.; Cox, David E.; Muri, Daniel G.

    2012-01-01

    This paper proposes a framework for studying the ability of a control strategy, consisting of a control law and a command law, to recover an aircraft from ight conditions that may extend beyond the normal ight envelope. This study was carried out (i) by evaluating time responses of particular ight upsets, (ii) by evaluating local stability over an equilibrium manifold that included stall, and (iii) by bounding the set in the state space from where the vehicle can be safely own to wings-level ight. These states comprise what will be called the safely recoverable ight envelope (SRFE), which is a set containing the aircraft states from where a control strategy can safely stabilize the aircraft. By safe recovery it is implied that the tran- sient response stays between prescribed limits before converging to a steady horizontal ight. The calculation of the SRFE bounds yields the worst-case initial state corresponding to each control strategy. This information is used to compare alternative recovery strategies, determine their strengths and limitations, and identify the most e ective strategy. In regard to the control law, the authors developed feedback feedforward laws based on the gain scheduling of multivariable controllers. In regard to the command law, which is the mechanism governing the exogenous signals driving the feed- forward component of the controller, we developed laws with a feedback structure that combines local stability and transient response considera- tions. The upset recovery of the Generic Transport Model, a sub-scale twin-engine jet vehicle developed by NASA Langley Research Center, is used as a case study.

  11. Thermal Comfort and Strategies for Energy Conservation.

    ERIC Educational Resources Information Center

    Rohles, Frederick H., Jr.

    1981-01-01

    Discusses studies in thermal comfort which served as the basis for the comfort standard. Examines seven variables in the human response to the thermal environment in terms of the ways in which they can be modified to conserve energy. (Author/MK)

  12. Control strategies used in the control software for the Heavy Ion Research Facility in Lanzhou

    NASA Astrophysics Data System (ADS)

    Zhou, Wen-Xiong; Wang, Yan-Yu; Pan, Liang-Ming; Tu, Sheng-Pan

    2016-07-01

    Automation control systems are important for the operation of an accelerator. To ensure the reliable, stable and flexible operation of the Heavy Ion Research Facility in Lanzhou (HIRFL), several control systems are developed. The developed control systems are the SECRAL control system, the LECR3 control system, the LAPECR1 control system and the Electro-Static septum control system. The corresponding control software systems are developed using Visual C++. To ensure the accuracy, stability and flexibility of the control systems, some special control strategies are developed in the control software systems. This paper provides a detailed description of the main control strategies used in the control software systems. The main control strategies are composed of a reliable communication mechanism, a correct data/command transmission mechanism, an efficient data storage mechanism and an interlock protection mechanism. To guarantee a reliable communication between the devices for the commercially purchased devices and the built in-house ones, a modified heartbeat method is developed. To provide flexible reconstitution function for the control systems, the command queue and the state machine are combined. The message mechanism and the multiple windows mechanism are also used for the module mechanism. The relevant control systems are introduced as examples of these control strategies. These systems have been running stably for several years.

  13. Self-control of epileptic seizures by nonpharmacological strategies.

    PubMed

    Kotwas, Iliana; McGonigal, Aileen; Trebuchon, Agnès; Bastien-Toniazzo, Mireille; Nagai, Yoko; Bartolomei, Fabrice; Micoulaud-Franchi, Jean-Arthur

    2016-02-01

    Despite the unpredictability of epileptic seizures, many patients report that they can anticipate seizure occurrence. Using certain alert symptoms (i.e., auras, prodromes, precipitant factors), patients can adopt behaviors to avoid injury during and after the seizure or may implement spontaneous cognitive and emotional strategies to try to control the seizure itself. From the patient's view point, potential means of enhancing seizure prediction and developing seizure control supports are seen as very important issues, especially when the epilepsy is drug-resistant. In this review, we first describe how some patients anticipate their seizures and whether this is effective in terms of seizure prediction. Secondly, we examine how these anticipatory elements might help patients to prevent or control their seizures and how the patient's neuropsychological profile, specifically parameters of perceived self-control (PSC) and locus of control (LOC), might impact these strategies and quality of life (QOL). Thirdly, we review the external supports that can help patients to better predict seizures. Finally, we look at nonpharmacological means of increasing perceived self-control and achieving potential reduction of seizure frequency (i.e., stress-based and arousal-based strategies). In the past few years, various approaches for detection and control of seizures have gained greater interest, but more research is needed to confirm a positive effect on seizure frequency as well as on QOL. PMID:26780213

  14. Energy options and strategies for Western europe.

    PubMed

    Häfele, W; Sassin, W

    1978-04-14

    Western Europe, now largely dependent on oil imports, has to prepare for strong competition for oil and energy imports in general before the year 2000. The more unlikely it is for Western Europe to secure from outside rich supplies of coal or uranium at readily acceptable economic and political conditions, the more serious this competition becomes. Even exceptionally low projections of economic growth and optimistic assumptions about energy conservation urgently call for vigorous and simultaneous development of indigenous coal and nuclear sources, including the breeder. Long-term contracts for the possession and deployment of foreign oil, gas, and coal deposits are mandatory and should be negotiated in view of the possible aggravation of north-south confrontation. PMID:17818793

  15. Emerging trends in vibration control of wind turbines: a focus on a dual control strategy.

    PubMed

    Staino, Andrea; Basu, Biswajit

    2015-02-28

    The paper discusses some of the recent developments in vibration control strategies for wind turbines, and in this context proposes a new dual control strategy based on the combination and modification of two recently proposed control schemes. Emerging trends in the vibration control of both onshore and offshore wind turbines are presented. Passive, active and semi-active structural vibration control algorithms have been reviewed. Of the existing controllers, two control schemes, active pitch control and active tendon control, have been discussed in detail. The proposed new control scheme is a merger of active tendon control with passive pitch control, and is designed using a Pareto-optimal problem formulation. This combination of controllers is the cornerstone of a dual strategy with the feature of decoupling vibration control from optimal power control as one of its main advantages, in addition to reducing the burden on the pitch demand. This dual control strategy will bring in major benefits to the design of modern wind turbines and is expected to play a significant role in the advancement of offshore wind turbine technologies. PMID:25583867

  16. 40 CFR 52.65 - Control Strategy: Nitrogen oxides.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... oxides. On October 22, 1990, the Alabama Department of Environmental Management submitted a revision to... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Control Strategy: Nitrogen oxides. 52.65 Section 52.65 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR...

  17. 40 CFR 52.1342 - Control strategy: Ozone.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., in accordance with 40 CFR 51.918, suspends the requirements for this area to submit an attainment... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Ozone. 52.1342...: Ozone. Determination of Attainment. EPA has determined, as of June 9, 2011, that the St. Louis...

  18. 40 CFR 52.2332 - Control Strategy: Ozone.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 5 2013-07-01 2013-07-01 false Control Strategy: Ozone. 52.2332...: Ozone. Determinations—EPA is determining that, as of July 18, 1995, the Salt Lake and Davis Counties ozone nonattainment area has attained the ozone standard based on air quality monitoring data from...

  19. 40 CFR 52.1885 - Control strategy: Ozone.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., see the List of CFR Sections Affected, which appears in the Finding Aids section of the printed volume... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Ozone. 52.1885...: Ozone. (a) Part D—Approval. The following portions of the Ohio plan are approved: (1) The ozone...

  20. 40 CFR 52.1342 - Control strategy: Ozone.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... determination, in accordance with 40 CFR 51.918, suspends the requirements for this area to submit an attainment... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Ozone. 52.1342...: Ozone. (a) Determination of attainment. EPA has determined, as of June 9, 2011, that the St. Louis...

  1. 40 CFR 52.2332 - Control Strategy: Ozone.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 5 2012-07-01 2012-07-01 false Control Strategy: Ozone. 52.2332...: Ozone. Determinations—EPA is determining that, as of July 18, 1995, the Salt Lake and Davis Counties ozone nonattainment area has attained the ozone standard based on air quality monitoring data from...

  2. 40 CFR 52.1885 - Control strategy: Ozone.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Register citations affecting § 52.1885, see the List of CFR Sections Affected, which appears in the Finding... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Ozone. 52.1885...: Ozone. (a) Part D—Approval. The following portions of the Ohio plan are approved: (1) The ozone...

  3. 40 CFR 52.2332 - Control Strategy: Ozone.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 5 2014-07-01 2014-07-01 false Control Strategy: Ozone. 52.2332...: Ozone. Determinations—EPA is determining that, as of July 18, 1995, the Salt Lake and Davis Counties ozone nonattainment area has attained the ozone standard based on air quality monitoring data from...

  4. 40 CFR 52.1885 - Control strategy: Ozone.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Register citations affecting § 52.1885, see the List of CFR Sections Affected, which appears in the Finding... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Ozone. 52.1885...: Ozone. (a) Part D—Approval. The following portions of the Ohio plan are approved: (1) The ozone...

  5. 40 CFR 52.1342 - Control strategy: Ozone.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... determination, in accordance with 40 CFR 51.918, suspends the requirements for this area to submit an attainment... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Ozone. 52.1342...: Ozone. (a) Determination of attainment. EPA has determined, as of June 9, 2011, that the St. Louis...

  6. 40 CFR 52.1342 - Control strategy: Ozone.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... determination, in accordance with 40 CFR 51.918, suspends the requirements for this area to submit an attainment... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Ozone. 52.1342...: Ozone. (a) Determination of attainment. EPA has determined, as of June 9, 2011, that the St. Louis...

  7. 40 CFR 52.2332 - Control Strategy: Ozone.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control Strategy: Ozone. 52.2332...: Ozone. Determinations—EPA is determining that, as of July 18, 1995, the Salt Lake and Davis Counties ozone nonattainment area has attained the ozone standard based on air quality monitoring data from...

  8. 40 CFR 52.977 - Control strategy and regulations: Ozone.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy and regulations: Ozone... and regulations: Ozone. Determination of Attainment. Effective March 12, 2010 EPA has determined the Baton Rouge 1-hour ozone nonattainment area has attained the 1-hour ozone National Ambient Air...

  9. 40 CFR 52.1885 - Control strategy: Ozone.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .... Editorial Note: For Federal Register citations affecting § 52.1885, see the List of CFR Sections Affected... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Ozone. 52.1885...: Ozone. (a) Part D—Approval. The following portions of the Ohio plan are approved: (1) The ozone...

  10. SMOG CHAMBER EXPERIMENTS TO TEST OXIDANT RELATED CONTROL STRATEGY ISSUES

    EPA Science Inventory

    Outdoor smog chamber experiments were performed to address various issues relating to ozone (O3) production and oxidant control strategies. Temperature effects on single hydrocarbon-NOx systems were studied. Propylene-NOx systems were modeled with particular attention to peroxyni...

  11. 40 CFR 52.1341 - Control strategy: particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... This determination, in accordance with 40 CFR 51.1004(c), suspends the requirements for this area to... area has attained the 1997 PM2.5 NAAQS. This determination, in accordance with 40 CFR 51.1004(c... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: particulate...

  12. 40 CFR 52.2059 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... the 1997 PM2.5 NAAQS. This determination, in accordance with 40 CFR 52.1004(c), suspends the... nonattainment areas have clean data for the 1997 PM2.5 NAAQS. This determination, in accordance with 40 CFR 52... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Particulate...

  13. 40 CFR 52.427 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... nonattainment area has attained the 1997 annual PM2.5 NAAQS. This determination, in accordance with 40 CFR 51... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Control strategy: Particulate matter...: Particulate matter. (a) Determination of attainment. EPA has determined, as of May 16, 2012, that based...

  14. 40 CFR 52.332 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ....332, see the List of CFR Sections Affected, which appears in the Finding Aids section of the printed... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Control strategy: Particulate matter...: Particulate matter. (a) On April 9, 1992, the Governor of Colorado submitted the moderate PM-10...

  15. 40 CFR 52.2059 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the 1997 PM2.5 NAAQS. This determination, in accordance with 40 CFR 52.1004(c), suspends the... nonattainment areas have clean data for the 1997 PM2.5 NAAQS. This determination, in accordance with 40 CFR 52... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Particulate...

  16. 40 CFR 52.427 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... area has attained the 1997 annual PM2.5 NAAQS. This determination, in accordance with 40 CFR 51.1004(c... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control strategy: Particulate matter...: Particulate matter. Determination of attainment. EPA has determined, as of May 16, 2012, that based on 2007...

  17. 40 CFR 52.1081 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 1997 PM2.5 NAAQS has attained the 1997 PM2.5 NAAQS. This determination, in accordance with 40 CFR 52..., in accordance with 40 CFR 52.1004(c), suspend the requirements for this area to submit an attainment... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Particulate...

  18. 40 CFR 52.1081 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 1997 PM2.5 NAAQS has attained the 1997 PM2.5 NAAQS. This determination, in accordance with 40 CFR 52..., in accordance with 40 CFR 52.1004(c), suspend the requirements for this area to submit an attainment... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Particulate...

  19. 40 CFR 52.332 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... Editorial Note: For Federal Register citations affecting § 52.332, see the List of CFR Sections Affected... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control strategy: Particulate matter...: Particulate matter. (a) On April 9, 1992, the Governor of Colorado submitted the moderate PM-10...

  20. 40 CFR 52.427 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... nonattainment area has attained the 1997 annual PM2.5 NAAQS. This determination, in accordance with 40 CFR 51... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Control strategy: Particulate matter...: Particulate matter. (a) Determination of attainment. EPA has determined, as of May 16, 2012, that based...

  1. 40 CFR 52.332 - Control strategy: Particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... Editorial Note: For Federal Register citations affecting § 52.332, see the List of CFR Sections Affected... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Control strategy: Particulate matter...: Particulate matter. (a) On April 9, 1992, the Governor of Colorado submitted the moderate PM-10...

  2. 40 CFR 123.46 - Individual control strategies.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... satisfies the criteria for listing under CWA section 304(l) and 40 CFR 130.10(d)(6). (e) If the Regional... CFR part 122, including § 122.44(d). At any time after the Regional Administrator disapproves an ICS... PROGRAM REQUIREMENTS Transfer of Information and Permit Review § 123.46 Individual control strategies....

  3. 40 CFR 52.330 - Control strategy: Total suspended particulates.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... State demonstrates by December 31, 1981, through air quality modeling, attainment of the 24-hour and... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Control strategy: Total suspended particulates. 52.330 Section 52.330 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)...

  4. 40 CFR 52.330 - Control strategy: Total suspended particulates.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... State demonstrates by December 31, 1981, through air quality modeling, attainment of the 24-hour and... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Control strategy: Total suspended particulates. 52.330 Section 52.330 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)...

  5. 40 CFR 52.330 - Control strategy: Total suspended particulates.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... State demonstrates by December 31, 1981, through air quality modeling, attainment of the 24-hour and... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Control strategy: Total suspended particulates. 52.330 Section 52.330 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)...

  6. 40 CFR 52.330 - Control strategy: Total suspended particulates.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... State demonstrates by December 31, 1981, through air quality modeling, attainment of the 24-hour and... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Control strategy: Total suspended particulates. 52.330 Section 52.330 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)...

  7. 40 CFR 52.330 - Control strategy: Total suspended particulates.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... State demonstrates by December 31, 1981, through air quality modeling, attainment of the 24-hour and... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Control strategy: Total suspended particulates. 52.330 Section 52.330 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)...

  8. 40 CFR 52.930 - Control strategy: Ozone.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Control strategy: Ozone. 52.930 Section 52.930 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED... year 2012. (l) Disapproval. EPA is disapproving in part, the Commonwealth of Kentucky's...

  9. 40 CFR 52.930 - Control strategy: Ozone.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Control strategy: Ozone. 52.930 Section 52.930 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED... year 2012. (l) Disapproval. EPA is disapproving in part, the Commonwealth of Kentucky's...

  10. 40 CFR 52.1129 - Control strategy: Ozone.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Ozone. 52.1129 Section 52.1129 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Massachusetts § 52.1129...

  11. 40 CFR 52.1129 - Control strategy: Ozone.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Ozone. 52.1129 Section 52.1129 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Massachusetts § 52.1129...

  12. 40 CFR 52.1129 - Control strategy: Ozone.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 CFR 51.918), this determination suspends the reasonable further progress and attainment... of EPA's ozone implementation rule (see 40 CFR 51.918), this determination suspends the reasonable... 40 Protection of Environment 4 2014-07-01 2014-07-01 false Control strategy: Ozone....

  13. 40 CFR 52.1129 - Control strategy: Ozone.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 CFR 51.918), this determination suspends the reasonable further progress and attainment... of EPA's ozone implementation rule (see 40 CFR 51.918), this determination suspends the reasonable... 40 Protection of Environment 4 2013-07-01 2013-07-01 false Control strategy: Ozone....

  14. 40 CFR 52.1129 - Control strategy: Ozone.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 CFR 51.918), this determination suspends the reasonable further progress and attainment... ozone standard. Under the provisions of EPA's ozone implementation rule (see 40 CFR 51.918), this... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Ozone....

  15. EVALUATION OF FLEXIBLE AND INNOVATIVE STRATEGIES FOR OZONE CONTROL

    EPA Science Inventory

    This Task provides the scientific understanding, evidence and tools needed by the Agency and States to evaluate the feasibility of using a reactivity-based control strategy for VOCs, based on the potential ozone and PM formation characteristics of individual VOCs. The research d...

  16. Adaptive Insecure Attachment and Resource Control Strategies during Middle Childhood

    ERIC Educational Resources Information Center

    Chen, Bin-Bin; Chang, Lei

    2012-01-01

    By integrating the life history theory of attachment with resource control theory, the current study examines the hypothesis that insecure attachment styles reorganized in middle childhood are alternative adaptive strategies used to prepare for upcoming competition with the peer group. A sample of 654 children in the second through seventh grades…

  17. 40 CFR 52.1030 - Control strategy: Sulfur oxides.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Sulfur oxides. 52.1030 Section 52.1030 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS...: Sulfur oxides. (a) The revision to Regulation 100.6 (Chapter 106) “Low Sulfur Fuel Regulation” for...

  18. 40 CFR 52.1117 - Control strategy: Sulfur oxides.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Sulfur oxides. 52...: Sulfur oxides. (a) (b) The requirements of § 51.112(a) of this chapter are not met because the State did....04B (1) and (2) would not interfere with the attainment and maintenance of the national sulfur...

  19. 40 CFR 52.1340 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 4 2012-07-01 2012-07-01 false Control strategy: Carbon monoxide. 52.1340 Section 52.1340 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS...: Carbon monoxide. Approval—A maintenance plan and redesignation request for the St. Louis, Missouri,...

  20. 40 CFR 52.1179 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 4 2011-07-01 2011-07-01 false Control strategy: Carbon monoxide. 52.1179 Section 52.1179 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS...: Carbon monoxide. (a) Approval—On March 18, 1999, the Michigan Department of Environmental...