Science.gov

Sample records for eyes detectrors based

  1. Feature-based eye corner detection from static images

    NASA Astrophysics Data System (ADS)

    Xia, Haiying; Yan, Guoping; You, Chao

    2009-10-01

    Eye corner detection is important for eye extraction, face normalization, other facial landmark extraction and so on. We present a feature-based method for eye corner detection from static images in this paper. This method is capable of locating eye corners automatically. The process of eye corner detection is divided into two stages: classifier training and classifier application. For training, two classifiers trained by AdaBoost with Haar-like features, are skillfully designed to detect inner eye corners and outer eye corners. Then, two classifiers are applied to input images to search targets. Eye corners are finally located according to two eye models from targets. Experimental results tested on BioID face database and our own database demonstrate that our method obtains a high accuracy under clutter conditions.

  2. Segmentation method of eye region based on fuzzy logic system for classifying open and closed eyes

    NASA Astrophysics Data System (ADS)

    Kim, Ki Wan; Lee, Won Oh; Kim, Yeong Gon; Hong, Hyung Gil; Lee, Eui Chul; Park, Kang Ryoung

    2015-03-01

    The classification of eye openness and closure has been researched in various fields, e.g., driver drowsiness detection, physiological status analysis, and eye fatigue measurement. For a classification with high accuracy, accurate segmentation of the eye region is required. Most previous research used the segmentation method by image binarization on the basis that the eyeball is darker than skin, but the performance of this approach is frequently affected by thick eyelashes or shadows around the eye. Thus, we propose a fuzzy-based method for classifying eye openness and closure. First, the proposed method uses I and K color information from the HSI and CMYK color spaces, respectively, for eye segmentation. Second, the eye region is binarized using the fuzzy logic system based on I and K inputs, which is less affected by eyelashes and shadows around the eye. The combined image of I and K pixels is obtained through the fuzzy logic system. Third, in order to reflect the effect by all the inference values on calculating the output score of the fuzzy system, we use the revised weighted average method, where all the rectangular regions by all the inference values are considered for calculating the output score. Fourth, the classification of eye openness or closure is successfully made by the proposed fuzzy-based method with eye images of low resolution which are captured in the environment of people watching TV at a distance. By using the fuzzy logic system, our method does not require the additional procedure of training irrespective of the chosen database. Experimental results with two databases of eye images show that our method is superior to previous approaches.

  3. Model-based dose calculations for COMS eye plaque brachytherapy using an anatomically realistic eye phantom

    SciTech Connect

    Lesperance, Marielle; Inglis-Whalen, M.; Thomson, R. M.

    2014-02-15

    Purpose : To investigate the effects of the composition and geometry of ocular media and tissues surrounding the eye on dose distributions for COMS eye plaque brachytherapy with{sup 125}I, {sup 103}Pd, or {sup 131}Cs seeds, and to investigate doses to ocular structures. Methods : An anatomically and compositionally realistic voxelized eye model with a medial tumor is developed based on a literature review. Mass energy absorption and attenuation coefficients for ocular media are calculated. Radiation transport and dose deposition are simulated using the EGSnrc Monte Carlo user-code BrachyDose for a fully loaded COMS eye plaque within a water phantom and our full eye model for the three radionuclides. A TG-43 simulation with the same seed configuration in a water phantom neglecting the plaque and interseed effects is also performed. The impact on dose distributions of varying tumor position, as well as tumor and surrounding tissue media is investigated. Each simulation and radionuclide is compared using isodose contours, dose volume histograms for the lens and tumor, maximum, minimum, and average doses to structures of interest, and doses to voxels of interest within the eye. Results : Mass energy absorption and attenuation coefficients of the ocular media differ from those of water by as much as 12% within the 20–30 keV photon energy range. For all radionuclides studied, average doses to the tumor and lens regions in the full eye model differ from those for the plaque in water by 8%–10% and 13%–14%, respectively; the average doses to the tumor and lens regions differ between the full eye model and the TG-43 simulation by 2%–17% and 29%–34%, respectively. Replacing the surrounding tissues in the eye model with water increases the maximum and average doses to the lens by 2% and 3%, respectively. Substituting the tumor medium in the eye model for water, soft tissue, or an alternate melanoma composition affects tumor dose compared to the default eye model

  4. A wide angle low coherence interferometry based eye length optometer

    NASA Astrophysics Data System (ADS)

    Meadway, Alexander; Siegwart, John; Wildsoet, Christine; Norton, Thomas; Zhang, Yuhua

    2015-03-01

    Interest in eye growth regulation has burgeoned with the rise in myopia prevalence world-wide. Eye length and eye shape are fundamental metrics for related research, but current in vivo measurement techniques are generally limited to the optical axis of the eye. We describe a high resolution, time domain low coherence interferometry based optometer for measuring the eye length of small animals over a wide field of view. The system is based upon a Michelson interferometer using a superluminescent diode as a source, including a sample arm and a reference arm. The sample arm is split into two paths by a polarisation beam splitter; one focuses the light on the cornea and the other focuses the light on the retina. This method has a high efficiency of detection for reflections from both surfaces. The reference arm contains a custom high speed linear motor with 25 mm stroke and equipped with a precision displacement encoder. Light reflected from the cornea and the retina is combined with the reference beam to generate low coherence interferograms. Two galvo scanners are employed to steer the light to different angles so that the eye length over a field of view of 20° × 20° can be measured. The system has an axial resolution of 6.8 μm (in air) and the motor provides accurate movement, allowing for precise and repeatable measurement of coherence peak positions. Example scans from a tree shrew are presented.

  5. simEye: Computer-based simulation of visual perception under various eye defects using Zernike polynomials.

    PubMed

    Fink, Wolfgang; Micol, Daniel

    2006-01-01

    We describe a computer eye model that allows for aspheric surfaces and a three-dimensional computer-based ray-tracing technique to simulate optical properties of the human eye and visual perception under various eye defects. Eye surfaces, such as the cornea, eye lens, and retina, are modeled or approximated by a set of Zernike polynomials that are fitted to input data for the respective surfaces. A ray-tracing procedure propagates light rays using Snell's law of refraction from an input object (e.g., digital image) through the eye under investigation (i.e., eye with defects to be modeled) to form a retinal image that is upside down and left-right inverted. To obtain a first-order realistic visual perception without having to model or simulate the retina and the visual cortex, this retinal image is then back-propagated through an emmetropic eye (e.g., Gullstrand exact schematic eye model with no additional eye defects) to an output screen of the same dimensions and at the same distance from the eye as the input object. Visual perception under instances of emmetropia, regular astigmatism, irregular astigmatism, and (central symmetric) keratoconus is simulated and depicted. In addition to still images, the computer ray-tracing tool presented here (simEye) permits the production of animated movies. These developments may have scientific and educational value. This tool may facilitate the education and training of both the public, for example, patients before undergoing eye surgery, and those in the medical field, such as students and professionals. Moreover, simEye may be used as a scientific research tool to investigate optical lens systems in general and the visual perception under a variety of eye conditions and surgical procedures such as cataract surgery and laser assisted in situ keratomileusis (LASIK) in particular. PMID:17092160

  6. EEG and eye-tracking based measures for enhanced training.

    PubMed

    Soussou, Walid; Rooksby, Michael; Forty, Charles; Weatherhead, James; Marshall, Sandra

    2012-01-01

    This paper describes a project whose goal was to establish the feasibility of using unobtrusive cognitive assessment methodologies in order to optimize efficiency and expediency of training. QUASAR, EyeTracking, Inc. (ETI), and Safe Passage International (SPI), teamed to demonstrate correlation between EEG and eye-tracking based cognitive workload, performance assessment and subject expertise on X-Ray screening tasks. Results indicate significant correlation between cognitive workload metrics based on EEG and eye-tracking measurements recorded during a simulated baggage screening task and subject expertise and error rates in that same task. These results suggest that cognitive monitoring could be useful in improving training efficiency by enabling training paradigms that adapts to increasing expertise. PMID:23366217

  7. Context-based questions: optics in animal eyes

    NASA Astrophysics Data System (ADS)

    Kaltakci, Derya; Eryilmaz, Ali

    2011-05-01

    Context is important as a motivational factor for student involvement with physics. The diversity in the types and the functions of animal eyes is an excellent context in which to achieve this goal. There exists a range of subtopics in optics including pinhole, reflection, refraction, and superposition that can be discussed in the context of the animal eye. In addition to ordinary textbook optics questions, the use of context-based questions that model the real world may increase the students' motivation toward optics concepts and their understanding of them. In this article, different optical systems in animal eyes are discussed as a context to teach optics topics with context-based questions. The preliminary version of this study was presented at the International Conference of GIREP 2008 in Cyprus.

  8. Measuring eye movements during locomotion: filtering techniques for obtaining velocity signals from a video-based eye monitor

    NASA Technical Reports Server (NTRS)

    Das, V. E.; Thomas, C. W.; Zivotofsky, A. Z.; Leigh, R. J.

    1996-01-01

    Video-based eye-tracking systems are especially suited to studying eye movements during naturally occurring activities such as locomotion, but eye velocity records suffer from broad band noise that is not amenable to conventional filtering methods. We evaluated the effectiveness of combined median and moving-average filters by comparing prefiltered and postfiltered records made synchronously with a video eye-tracker and the magnetic search coil technique, which is relatively noise free. Root-mean-square noise was reduced by half, without distorting the eye velocity signal. To illustrate the practical use of this technique, we studied normal subjects and patients with deficient labyrinthine function and compared their ability to hold gaze on a visual target that moved with their heads (cancellation of the vestibulo-ocular reflex). Patients and normal subjects performed similarly during active head rotation but, during locomotion, patients held their eyes more steadily on the visual target than did subjects.

  9. Feature quality-based multimodal unconstrained eye recognition

    NASA Astrophysics Data System (ADS)

    Zhou, Zhi; Du, Eliza Y.; Lin, Yong; Thomas, N. Luke; Belcher, Craig; Delp, Edward J.

    2013-05-01

    Iris recognition has been tested to the most accurate biometrics using high resolution near infrared images. However, it does not work well under visible wavelength illumination. Sclera recognition, however, has been shown to achieve reasonable recognition accuracy under visible wavelengths. Combining iris and sclera recognition together can achieve better recognition accuracy. However, image quality can significantly affect the recognition accuracy. Moreover, in unconstrained situations, the acquired eye images may not be frontally facing. In this research, we proposed a feature quality-based multimodal unconstrained eye recognition method that combine the respective strengths of iris recognition and sclera recognition for human identification and can work with frontal and off-angle eye images. The research results show that the proposed method is very promising.

  10. Height estimations based on eye measurements throughout a gait cycle.

    PubMed

    Yang, Sylvia X M; Larsen, Peter K; Alkjær, Tine; Juul-Kristensen, Birgit; Simonsen, Erik B; Lynnerup, Niels

    2014-03-01

    Anthropometric measurements (e.g. the height to the head, nose tip, eyes or shoulders) of a perpetrator based on video material may be used in criminal cases. However, several height measurements may be difficult to assess as the perpetrators may be disguised by clothes or headwear. The eye height (EH) measurement, on the other hand, is less prone to concealment. The purpose of the present study was to investigate: (1) how the eye height varies during the gait cycle, and (2) how the eye height changes with head position. The eyes were plotted manually in APAS for 16 test subjects during a complete gait cycle. The influence of head tilt on the EH was investigated in 20 healthy men. Markers were attached to the face and the subjects were instructed to stand relaxed, tilt their head to the right, to the left, forward and backward. The marker data for the right eye were used to calculate the EH. The respective deviation and SD from the relaxed standing EH and the EH in the Frankfurt plane, left tilted, right tilted, forward tilted and backward tilted, in addition to the corresponding head tilt angles were calculated. There was no correlation between the height of the subject and the maximum vertical displacement of the EH throughout the gait cycle nor between height of the subjects and the variation of the EH throughout the gait cycle. The average maximum vertical displacement for the test subject group was 4.76 cm (± 1.56 cm). The average EH was lower when the subjects were standing in the relaxed position than in the Frankfurt plane. The average EH was higher in the relaxed position than when the subjects tilted their heads, except when they tilted their heads backwards. The subjects had a slightly larger range of motion to the right than to the left, which was not significant. The results of this study provide a range for eye height estimates and may be readily implemented in forensic case work. It can be used as a reference in height estimates in cases with height

  11. A low cost human computer interface based on eye tracking.

    PubMed

    Hiley, Jonathan B; Redekopp, Andrew H; Fazel-Rezai, Reza

    2006-01-01

    This paper describes the implementation of a human computer interface based on eye tracking. Current commercially available systems exist, but have limited use due mainly to their large cost. The system described in this paper was designed to be a low cost and unobtrusive. The technique was video-oculography assisted by corneal reflections. An off-the shelf CCD webcam was used to capture images. The images were analyzed in software to extract key features of the eye. The users gaze point was then calculated based on the relative position of these features. The system is capable of calculating eye-gaze in real-time to provide a responsive interaction. A throughput of eight gaze points per second was achieved. The accuracy of the fixations based on the calculated eye-gazes were within 1 cm of the on-screen gaze location. By developing a low-cost system, this technology is made accessible to a wider range of applications. PMID:17946167

  12. Model of the Human Eye Based on ABCD Matrix

    NASA Astrophysics Data System (ADS)

    González, G. Díaz; Castillo, M. David Iturbe

    2008-04-01

    At the moment several models of the human eye exist, nevertheless the gradient index models of the human lens (crystalline) have received little attention in optometry and vision sciences, although they consider how the refractive index and the refracting power can change with the accommodation. On the other hand, in study fields like ophthalmology and optometry, exist cases where there is a lack of information about the factors that influence the change of refractive power and therefore the focal length of the eye. By such reason, in this paper we present a model of the human eye based on the ABCD matrix in order to describe the propagation of light rays, that can be understood by professional people in optics, ophthalmology and optometry, and the dispersions of the different ocular mediums are taken into account,. The aim of the model is to obtain data about the refractive power of the eye under different considerations, such as: changes in wavelength, radius of curvature and thicknesses of the ocular mediums. We present results of simulations in Matlab of our model, assuming that the object is punctual and is placed to a certain distance of the eye, and considering at the beginning to the crystalline like a medium with fixed refractive index, and after like a gradient lens. By means of graphs, we show the total refractive power of the eye and its form and type of dependence with respect to variations in radius of curvature and thicknesses of the cornea and crystalline, as well as variations in the thickness of the previous and later cameras.

  13. Image-based modeling of the human eye.

    PubMed

    François, Guillaume; Gautron, Pascal; Breton, Gaspard; Bouatouch, Kadi

    2009-01-01

    Rendering realistic organic materials is a challenging issue. The human eye is an important part of nonverbal communication which, consequently, requires specific modeling and rendering techniques to enhance the realism of virtual characters. We propose an image-based method for estimating both iris morphology and scattering features in order to generate convincing images of virtual eyes. In this regard, we develop a technique to unrefract iris photographs. We model the morphology of the human iris as an irregular multilayered tissue. We then approximate the scattering features of the captured iris. Finally, we propose a real-time rendering technique based on the subsurface texture mapping representation and introduce a precomputed refraction function as well as a caustic function, which accounts for the light interactions at the corneal interface. PMID:19590107

  14. Driver fatigue alarm based on eye detection and gaze estimation

    NASA Astrophysics Data System (ADS)

    Sun, Xinghua; Xu, Lu; Yang, Jingyu

    2007-11-01

    The driver assistant system has attracted much attention as an essential component of intelligent transportation systems. One task of driver assistant system is to prevent the drivers from fatigue. For the fatigue detection it is natural that the information about eyes should be utilized. The driver fatigue can be divided into two types, one is the sleep with eyes close and another is the sleep with eyes open. Considering that the fatigue detection is related with the prior knowledge and probabilistic statistics, the dynamic Bayesian network is used as the analysis tool to perform the reasoning of fatigue. Two kinds of experiments are performed to verify the system effectiveness, one is based on the video got from the laboratory and another is based on the video got from the real driving situation. Ten persons participate in the test and the experimental result is that, in the laboratory all the fatigue events can be detected, and in the practical vehicle the detection ratio is about 85%. Experiments show that in most of situations the proposed system works and the corresponding performance is satisfying.

  15. Comparison of novel lipid-based eye drops with aqueous eye drops for dry eye: a multicenter, randomized controlled trial

    PubMed Central

    Simmons, Peter A; Carlisle-Wilcox, Cindy; Vehige, Joseph G

    2015-01-01

    Background Dry eye may be caused or exacerbated by deficient lipid secretion. Recently, lipid-containing artificial tears have been developed to alleviate this deficiency. Our study compared the efficacy, safety, and acceptability of lipid-containing eye drops with that of aqueous eye drops. Methods A non-inferiority, randomized, parallel-group, investigator-masked multicenter trial was conducted. Subjects with signs and symptoms of dry eye were randomized to use one of two lipid-containing artificial tears, or one of two aqueous artificial tears. Subjects instilled assigned drops in each eye at least twice daily for 30 days. The primary efficacy analysis tested non-inferiority of a preservative-free lipid tear formulation (LT UD) to a preservative-free aqueous tear formulation (AqT UD) for change in Ocular Surface Disease Index (OSDI) score from baseline at day 30. Secondary measures included OSDI at day 7, tear break-up time (TBUT), corneal and conjunctival staining, Schirmer’s test, acceptability and usage questionnaires, and safety assessments. Results A total of 315 subjects were randomized and included in the analyses. Subjects reported instilling a median of three doses of study eye drops per day in all groups. At days 7 and 30, all groups showed statistically significant improvements from baseline in OSDI (P<0.001) and TBUT (P≤0.005). LT UD was non-inferior to AqT UD for mean change from baseline in OSDI score at day 30. No consistent or clinically relevant differences for the other efficacy variables were observed. Acceptability was generally similar across the groups and there was a low incidence of adverse events. Conclusion In this heterogeneous population of dry eye subjects, there were no clinically significant differences in safety, effectiveness, and acceptability between lipid-containing artificial tears and aqueous eye drops. The results suggest that lipid-containing artificial tears can be used to counteract lipid deficiency that is common in

  16. Characterization of porcine eyes based on autofluorescence lifetime imaging

    NASA Astrophysics Data System (ADS)

    Batista, Ana; Breunig, Hans Georg; Uchugonova, Aisada; Morgado, António Miguel; König, Karsten

    2015-03-01

    Multiphoton microscopy is a non-invasive imaging technique with ideal characteristics for biological applications. In this study, we propose to characterize three major structures of the porcine eye, the cornea, crystalline lens, and retina using two-photon excitation fluorescence lifetime imaging microscopy (2PE-FLIM). Samples were imaged using a laser-scanning microscope, consisting of a broadband sub-15 femtosecond (fs) near-infrared laser. Signal detection was performed using a 16-channel photomultiplier tube (PMT) detector (PML-16PMT). Therefore, spectral analysis of the fluorescence lifetime data was possible. To ensure a correct spectral analysis of the autofluorescence lifetime data, the spectra of the individual endogenous fluorophores were acquired with the 16-channel PMT and with a spectrometer. All experiments were performed within 12h of the porcine eye enucleation. We were able to image the cornea, crystalline lens, and retina at multiple depths. Discrimination of each structure based on their autofluorescence intensity and lifetimes was possible. Furthermore, discrimination between different layers of the same structure was also possible. To the best of our knowledge, this was the first time that 2PE-FLIM was used for porcine lens imaging and layer discrimination. With this study we further demonstrated the feasibility of 2PE-FLIM to image and differentiate three of the main components of the eye and its potential as an ophthalmologic technique.

  17. Research on moving object detection based on frog's eyes

    NASA Astrophysics Data System (ADS)

    Fu, Hongwei; Li, Dongguang; Zhang, Xinyuan

    2008-12-01

    On the basis of object's information processing mechanism with frog's eyes, this paper discussed a bionic detection technology which suitable for object's information processing based on frog's vision. First, the bionics detection theory by imitating frog vision is established, it is an parallel processing mechanism which including pick-up and pretreatment of object's information, parallel separating of digital image, parallel processing, and information synthesis. The computer vision detection system is described to detect moving objects which has special color, special shape, the experiment indicates that it can scheme out the detecting result in the certain interfered background can be detected. A moving objects detection electro-model by imitating biologic vision based on frog's eyes is established, the video simulative signal is digital firstly in this system, then the digital signal is parallel separated by FPGA. IN the parallel processing, the video information can be caught, processed and displayed in the same time, the information fusion is taken by DSP HPI ports, in order to transmit the data which processed by DSP. This system can watch the bigger visual field and get higher image resolution than ordinary monitor systems. In summary, simulative experiments for edge detection of moving object with canny algorithm based on this system indicate that this system can detect the edge of moving objects in real time, the feasibility of bionic model was fully demonstrated in the engineering system, and it laid a solid foundation for the future study of detection technology by imitating biologic vision.

  18. Optic nerve head perfusion in normal eyes and eyes with glaucoma using optical coherence tomography-based microangiography

    PubMed Central

    Chen, Chieh-Li; Bojikian, Karine D.; Gupta, Divakar; Wen, Joanne C.; Zhang, Qinqin; Xin, Chen; Kono, Rei; Mudumbai, Raghu C.; Johnstone, Murray A.; Chen, Philip P.

    2016-01-01

    Background To investigate the differences of perfusion in the optic nerve head (ONH) between normal and glaucomatous eyes using optical microangiography (OMAG) based optical coherence tomography (OCT) angiography technique. Methods One eye from each subject was scanned with a 68 kHz Cirrus 5000 HD-OCT-based OMAG prototype system centered at the ONH (Carl Zeiss Meditec Inc, Dublin, CA, USA). Microvascular images were generated from the OMAG dataset by detecting the differences in OCT signal between consecutive B-scans. The pre-laminar layer (preLC) was isolated by a semi-automatic segmentation program. En face OMAG images for preLC were generated using signals with highest blood flow signal intensity. ONH perfusion was quantified as flux, vessel area density, and normalized flux within the ONH. Standard t-tests were performed to analyze the ONH perfusion differences between normal and glaucomatous eyes. Linear regression models were constructed to analyze the correlation between ONH perfusion and other clinical measurements. Results Twenty normal and 21 glaucoma subjects were enrolled. Glaucomatous eyes had significantly lower ONH perfusion in preLC in all three perfusion metrics compared to normal eyes (P≤0.0003). Significant correlations between ONH perfusion and disease severity as well as structural changes were detected in glaucomatous eyes (P≤0.012). Conclusions ONH perfusion detected by OMAG showed significant differences between glaucoma and normal controls and was significantly correlated with disease severity and structural defects in glaucomatous eyes. ONH perfusion measurement using OMAG may provide useful information for detection and monitoring of glaucoma. PMID:27190764

  19. CUE: counterfeit-resistant usable eye movement-based authentication via oculomotor plant characteristics and complex eye movement patterns

    NASA Astrophysics Data System (ADS)

    Komogortsev, Oleg V.; Karpov, Alexey; Holland, Corey D.

    2012-06-01

    The widespread use of computers throughout modern society introduces the necessity for usable and counterfeit-resistant authentication methods to ensure secure access to personal resources such as bank accounts, e-mail, and social media. Current authentication methods require tedious memorization of lengthy pass phrases, are often prone to shouldersurfing, and may be easily replicated (either by counterfeiting parts of the human body or by guessing an authentication token based on readily available information). This paper describes preliminary work toward a counterfeit-resistant usable eye movement-based (CUE) authentication method. CUE does not require any passwords (improving the memorability aspect of the authentication system), and aims to provide high resistance to spoofing and shoulder-surfing by employing the combined biometric capabilities of two behavioral biometric traits: 1) oculomotor plant characteristics (OPC) which represent the internal, non-visible, anatomical structure of the eye; 2) complex eye movement patterns (CEM) which represent the strategies employed by the brain to guide visual attention. Both OPC and CEM are extracted from the eye movement signal provided by an eye tracking system. Preliminary results indicate that the fusion of OPC and CEM traits is capable of providing a 30% reduction in authentication error when compared to the authentication accuracy of individual traits.

  20. Head-mounted computer interface based on eye tracking

    NASA Astrophysics Data System (ADS)

    Schroeder, William E.

    1993-10-01

    A head-mounted computer interface using eye-tracking as a `pointer' was demonstrated at the Third Annual Weapons Technology Review and Training Exposition at San Diego in January 1992, and is under further development for military and civilian applications. in this interface, the computer interprets eye gaze direction just as it would input from a mouse or trackball. This technology makes possible computer-human interaction with many ideal aspects: complete portability, hands-free operation, silent, secure operation anywhere and any time. Commercial systems using control inputs from the tracked eye are available and effective within their limits, but size, weight, and cost have been barriers to wider use. This paper describes the latest head-mounted eye tracking display (HETD) development prototype. We are exploring the technological limits of current and near-term lighting, detector, and lens technology to project the feasibility of this device.

  1. Optimization of hyaluronan-based eye drop formulations.

    PubMed

    Salzillo, Rosanna; Schiraldi, Chiara; Corsuto, Luisana; D'Agostino, Antonella; Filosa, Rosanna; De Rosa, Mario; La Gatta, Annalisa

    2016-11-20

    Hyaluronan (HA) is frequently incorporated in eye drops to extend the pre-corneal residence time, due to its viscosifying and mucoadhesive properties. Hydrodynamic and rheological evaluations of commercial products are first accomplished revealing molecular weights varying from about 360 to about 1200kDa and viscosity values in the range 3.7-24.2mPa s. The latter suggest that most products could be optimized towards resistance to drainage from the ocular surface. Then, a study aiming to maximize the viscosity and mucoadhesiveness of HA-based preparations is performed. The effect of polymer chain length and concentration is investigated. For the whole range of molecular weights encountered in commercial products, the concentration maximizing performance is identified. Such concentration varies from 0.3 (wt%) for a 1100kDa HA up to 1.0 (wt%) for a 250kDa HA, which is 3-fold higher than the highest concentration on the market. The viscosity and mucoadhesion profiles of optimized formulations are superior than commercial products, especially under conditions simulating in vivo blinking. Thus longer retention on the corneal epithelium can be predicted. An enhanced capacity to protect corneal porcine epithelial cells from dehydration is also demonstrated in vitro. Overall, the results predict formulations with improved efficacy. PMID:27561497

  2. Implicit prosody mining based on the human eye image capture technology

    NASA Astrophysics Data System (ADS)

    Gao, Pei-pei; Liu, Feng

    2013-08-01

    The technology of eye tracker has become the main methods of analyzing the recognition issues in human-computer interaction. Human eye image capture is the key problem of the eye tracking. Based on further research, a new human-computer interaction method introduced to enrich the form of speech synthetic. We propose a method of Implicit Prosody mining based on the human eye image capture technology to extract the parameters from the image of human eyes when reading, control and drive prosody generation in speech synthesis, and establish prosodic model with high simulation accuracy. Duration model is key issues for prosody generation. For the duration model, this paper put forward a new idea for obtaining gaze duration of eyes when reading based on the eye image capture technology, and synchronous controlling this duration and pronunciation duration in speech synthesis. The movement of human eyes during reading is a comprehensive multi-factor interactive process, such as gaze, twitching and backsight. Therefore, how to extract the appropriate information from the image of human eyes need to be considered and the gaze regularity of eyes need to be obtained as references of modeling. Based on the analysis of current three kinds of eye movement control model and the characteristics of the Implicit Prosody reading, relative independence between speech processing system of text and eye movement control system was discussed. It was proved that under the same text familiarity condition, gaze duration of eyes when reading and internal voice pronunciation duration are synchronous. The eye gaze duration model based on the Chinese language level prosodic structure was presented to change previous methods of machine learning and probability forecasting, obtain readers' real internal reading rhythm and to synthesize voice with personalized rhythm. This research will enrich human-computer interactive form, and will be practical significance and application prospect in terms of

  3. Optimizations and Applications in Head-Mounted Video-Based Eye Tracking

    ERIC Educational Resources Information Center

    Li, Feng

    2011-01-01

    Video-based eye tracking techniques have become increasingly attractive in many research fields, such as visual perception and human-computer interface design. The technique primarily relies on the positional difference between the center of the eye's pupil and the first-surface reflection at the cornea, the corneal reflection (CR). This…

  4. Effects of Bilateral Eye Movements on Gist Based False Recognition in the DRM Paradigm

    ERIC Educational Resources Information Center

    Parker, Andrew; Dagnall, Neil

    2007-01-01

    The effects of saccadic bilateral (horizontal) eye movements on gist based false recognition was investigated. Following exposure to lists of words related to a critical but non-studied word participants were asked to engage in 30s of bilateral vs. vertical vs. no eye movements. Subsequent testing of recognition memory revealed that those who…

  5. Context-Based Questions: Optics in Animal Eyes

    ERIC Educational Resources Information Center

    Kaltakci, Derya; Eryilmaz, Ali

    2011-01-01

    Context is important as a motivational factor for student involvement with physics. The diversity in the types and the functions of animal eyes is an excellent context in which to achieve this goal. There exists a range of subtopics in optics including pinhole, reflection, refraction, and superposition that can be discussed in the context of the…

  6. Intraocular lens design for treating high myopia based on individual eye model

    NASA Astrophysics Data System (ADS)

    Wang, Yang; Wang, Zhaoqi; Wang, Yan; Zuo, Tong

    2007-02-01

    In this research, we firstly design the phakic intraocular lens (PIOL) based on individual eye model with optical design software ZEMAX. The individual PIOL is designed to correct the defocus and astigmatism, and then we compare the PIOL power calculated from the individual eye model with that from the experiential formula. Close values of PIOL power are obtained between the individual eye model and the formula, but the suggested method has more accuracy with more functions. The impact of PIOL decentration on human eye is evaluated, including rotation decentration, flat axis decentration, steep axis decentration and axial movement of PIOL, which is impossible with traditional method. To control the PIOL decentration errors, we give the limit values of PIOL decentration for the specific eye in this study.

  7. Full 3-D OCT-based pseudophakic custom computer eye model.

    PubMed

    Sun, M; Pérez-Merino, P; Martinez-Enriquez, E; Velasco-Ocana, M; Marcos, S

    2016-03-01

    We compared measured wave aberrations in pseudophakic eyes implanted with aspheric intraocular lenses (IOLs) with simulated aberrations from numerical ray tracing on customized computer eye models, built using quantitative 3-D OCT-based patient-specific ocular geometry. Experimental and simulated aberrations show high correlation (R = 0.93; p<0.0001) and similarity (RMS for high order aberrations discrepancies within 23.58%). This study shows that full OCT-based pseudophakic custom computer eye models allow understanding the relative contribution of optical geometrical and surgically-related factors to image quality, and are an excellent tool for characterizing and improving cataract surgery. PMID:27231608

  8. Full 3-D OCT-based pseudophakic custom computer eye model

    PubMed Central

    Sun, M.; Pérez-Merino, P.; Martinez-Enriquez, E.; Velasco-Ocana, M.; Marcos, S.

    2016-01-01

    We compared measured wave aberrations in pseudophakic eyes implanted with aspheric intraocular lenses (IOLs) with simulated aberrations from numerical ray tracing on customized computer eye models, built using quantitative 3-D OCT-based patient-specific ocular geometry. Experimental and simulated aberrations show high correlation (R = 0.93; p<0.0001) and similarity (RMS for high order aberrations discrepancies within 23.58%). This study shows that full OCT-based pseudophakic custom computer eye models allow understanding the relative contribution of optical geometrical and surgically-related factors to image quality, and are an excellent tool for characterizing and improving cataract surgery. PMID:27231608

  9. Risk functions for human and porcine eye rupture based on projectile characteristics of blunt objects.

    PubMed

    Kennedy, Eric A; Ng, Tracy P; McNally, Craig; Stitzel, Joel D; Duma, Stephan M

    2006-11-01

    Eye ruptures are among the most devastating eye injuries and can occur in automobile crashes, sporting impacts, and military events, where blunt projectile impacts to the eye can be encountered. The purpose of this study was to develop injury risk functions for globe rupture of both human and porcine eyes from blunt projectile impacts. This study was completed in two parts by combining published eye experiments with new test data. In the first part, data from 57 eye impact tests that were reported in the literature were analyzed. Projectile characteristics such as mass, cross-sectional area, and velocity, as well as injury outcome were noted for all tests. Data were sorted by species type and areas were identified where a paucity of data existed, based on the kinetic and normalized energy of assaulting objects. For the second part, a total of 126 projectile tests were performed on human and porcine eyes. Projectiles used for these tests included blunt aluminum projectiles, BBs, foam pellets, Airsoft pellets, and paintballs. Data for each projectile were recorded prior to testing and high-speed video was used to determine projectile velocity prior to striking the eye. In part three the data were pooled for a total of 183 eye impact tests, 83 human and 100 porcine, and were analyzed to develop the injury risk criteria. Binary logistic regression was used to develop injury risk functions based on kinetic and normalized energy. Probit analysis was used to estimate confidence intervals for the injury risk functions. Porcine eyes were found to be significantly stronger than human eyes in resisting globe rupture (p=0.01). For porcine eyes a 50% risk of globe rupture was found to be 71,145 J/m2, with a confidence interval of 63,245 J/m2 to 80,390 J/m2. Human eyes were found to have a 50% risk of globe rupture at a lower, 35,519 J/m2, with confidence intervals of 32,018 J/m2 to 40,641 J/m2. The results presented in this paper are useful in estimating the risk of globe

  10. Assessment of eye fatigue caused by 3D displays based on multimodal measurements.

    PubMed

    Bang, Jae Won; Heo, Hwan; Choi, Jong-Suk; Park, Kang Ryoung

    2014-01-01

    With the development of 3D displays, user's eye fatigue has been an important issue when viewing these displays. There have been previous studies conducted on eye fatigue related to 3D display use, however, most of these have employed a limited number of modalities for measurements, such as electroencephalograms (EEGs), biomedical signals, and eye responses. In this paper, we propose a new assessment of eye fatigue related to 3D display use based on multimodal measurements. compared to previous works Our research is novel in the following four ways: first, to enhance the accuracy of assessment of eye fatigue, we measure EEG signals, eye blinking rate (BR), facial temperature (FT), and a subjective evaluation (SE) score before and after a user watches a 3D display; second, in order to accurately measure BR in a manner that is convenient for the user, we implement a remote gaze-tracking system using a high speed (mega-pixel) camera that measures eye blinks of both eyes; thirdly, changes in the FT are measured using a remote thermal camera, which can enhance the measurement of eye fatigue, and fourth, we perform various statistical analyses to evaluate the correlation between the EEG signal, eye BR, FT, and the SE score based on the T-test, correlation matrix, and effect size. Results show that the correlation of the SE with other data (FT, BR, and EEG) is the highest, while those of the FT, BR, and EEG with other data are second, third, and fourth highest, respectively. PMID:25192315

  11. Assessment of Eye Fatigue Caused by 3D Displays Based on Multimodal Measurements

    PubMed Central

    Bang, Jae Won; Heo, Hwan; Choi, Jong-Suk; Park, Kang Ryoung

    2014-01-01

    With the development of 3D displays, user's eye fatigue has been an important issue when viewing these displays. There have been previous studies conducted on eye fatigue related to 3D display use, however, most of these have employed a limited number of modalities for measurements, such as electroencephalograms (EEGs), biomedical signals, and eye responses. In this paper, we propose a new assessment of eye fatigue related to 3D display use based on multimodal measurements. compared to previous works Our research is novel in the following four ways: first, to enhance the accuracy of assessment of eye fatigue, we measure EEG signals, eye blinking rate (BR), facial temperature (FT), and a subjective evaluation (SE) score before and after a user watches a 3D display; second, in order to accurately measure BR in a manner that is convenient for the user, we implement a remote gaze-tracking system using a high speed (mega-pixel) camera that measures eye blinks of both eyes; thirdly, changes in the FT are measured using a remote thermal camera, which can enhance the measurement of eye fatigue, and fourth, we perform various statistical analyses to evaluate the correlation between the EEG signal, eye BR, FT, and the SE score based on the T-test, correlation matrix, and effect size. Results show that the correlation of the SE with other data (FT, BR, and EEG) is the highest, while those of the FT, BR, and EEG with other data are second, third, and fourth highest, respectively. PMID:25192315

  12. Contact-flatted measurement of eye stiffness based on force-displacement relationship

    NASA Astrophysics Data System (ADS)

    Zhang, Jin; Ma, Jianguo; Zhang, Xueyong

    2011-12-01

    This paper presents a noninvasive approach in vivo measurement of eye stiffness based on a force-displacement relationship, which is based on a new contact-probe method of simultaneously measuring the static force and displacement. First, a simple spherical eye model is introduced for deriving analytical eye stiffness when a static force is applied to an eye. Next, a measurement system for simultaneously measuring force and displacement when a probe is pressed onto the eye is presented. Static eye stiffness is defined which based on the measured force-displacement relationship. A photoelectric probe transducer acts as displacement detector. A 16-bit single-chip microprocessor with E2PROM in the electronic circuit played the role of a nucleus, which stored the program instructions and the interrelated data. Laboratory experiments were carried out on a simulated eyeball connected to a hydraulic manometer to obtain intraocular pressure at different levels. The experimental results show that the measured eye stiffness nicely matches the analytical result.

  13. DNA-based eye colour prediction across Europe with the IrisPlex system.

    PubMed

    Walsh, Susan; Wollstein, Andreas; Liu, Fan; Chakravarthy, Usha; Rahu, Mati; Seland, Johan H; Soubrane, Gisele; Tomazzoli, Laura; Topouzis, Fotis; Vingerling, Johannes R; Vioque, Jesus; Fletcher, Astrid E; Ballantyne, Kaye N; Kayser, Manfred

    2012-05-01

    The ability to predict Externally Visible Characteristics (EVCs) from DNA, also referred to as Forensic DNA Phenotyping (FDP), is an exciting new chapter in forensic genetics holding great promise for tracing unknown individuals who are unidentifiable via standard forensic short tandem repeat (STR) profiling. For the purpose of DNA-based eye colour prediction, we previously developed the IrisPlex system consisting of a multiplex genotyping assay and a prediction model based on genotype and phenotype data from 3804 Dutch Europeans. Recently, we performed a forensic developmental validation study of the highly sensitive IrisPlex assay, which currently represents the only validated tool available for DNA-based prediction of eye colour in forensic applications. In the present study, we validate the IrisPlex prediction model by extending our initially described model towards genotype and phenotype data from multiple European populations. We performed IrisPlex analysis on 3840 individuals from seven sites across Europe as part of the European Eye (EUREYE) study for which DNA and high-resolution eye images were available. The accuracy rate of correctly predicting an individual's eye colour as being blue or brown, above the empirically established probability threshold of 0.7, was on average 94% across all seven European populations, ranging from 91% to 98%, despite the large variation in eye colour frequencies between the populations. The overall prediction accuracies expressed by the area under the receiver characteristic operating curves (AUC) were 0.96 for blue and 0.96 for brown eyes, which is considerably higher than those established before. The IrisPlex prediction model parameters generated from this multi-population European dataset, and thus its prediction capabilities, were highly comparable to those previously established. Therefore, the increased information regarding eye colour phenotype and genotype distributions across Europe, and the system's ability to

  14. Point detection and positioning system of the target based on surface cluster eyes

    NASA Astrophysics Data System (ADS)

    Guo, Fang; Zhang, Hao; Wang, Keyi

    2010-10-01

    The research of target detection and position is a challenge task in the fields where machine vision was used to develop various systems. However, monocular vision and binocular vision traditionally are difficult to meet the applications for high resolution and high sensitivity. Because compound eye imaging system is capacity of the large field of view for moving target detection with high sensitivity, the optical system has the potential to meet the applications above mentioned. In this paper, a preliminary exploration of the surface imaging system for the characteristics of cluster eyes was made and the optical signal processing methods of cluster eyes were introduced in detail. First the structure of the cluster eyes was described and the imaging channels of cluster eyes were ray traced with Zemax. Then based on the surface imaging mechanism with clusters eyes, the center of gravity of image space for target was extracted. Subsequently by the neural networks training based on LM (Levenberg-Marquardt) algorithm, the non-linear relationship between target and image was effectively calibrated. Finally, the corresponding relationship between target point and its image point among the various channels was established. The experimental results show that the multicast visual imaging systems are capable of providing the information of target azimuth and distance. Some attempts to study the systems were made to achieve high resolution, high sensitivity of target detection and positioning tasks. At the same time the surface imaging system also laid a solid foundation for the large compound eye imaging system from theory to practical application.

  15. Glucose sensing using the Brewster reflection: polarimetric ray-tracing based upon an anatomical eye model

    NASA Astrophysics Data System (ADS)

    Bockle, Stefan; Rovati, Luigi; Ansari, Rafat R.

    2003-07-01

    In this paper we present theoretical analysis to support the polarimetric approach for glucose detection in the human eye applying Brewster reflection off the ocular lens. The theoretical eye model of Navarro, which is based upon anatomical data, was used to perform ray-tracing, whereas the electromagnetic and polarization parameters of light propagation through the eye-media were calculated. The errors in glucose concentration determination due to refraction and deviation from the ideal optical path were calculated under different conditions. Effects of using incident linearly and circularly polarized light and variation of intersection condition of the incoming light beam with the anterior corneal surface were taken into consideration. Calculations were performed for a wide spectral range by applying dispersion curves for the eye-media. These simulations show the potential and the limits of the proposed optical approach.

  16. Quantitative evaluation of a low-cost noninvasive hybrid interface based on EEG and eye movement.

    PubMed

    Kim, Minho; Kim, Byung Hyung; Jo, Sungho

    2015-03-01

    This paper describes a low-cost noninvasive brain-computer interface (BCI) hybridized with eye tracking. It also discusses its feasibility through a Fitts' law-based quantitative evaluation method. Noninvasive BCI has recently received a lot of attention. To bring the BCI applications into real life, user-friendly and easily portable devices need to be provided. In this work, as an approach to realize a real-world BCI, electroencephalograph (EEG)-based BCI combined with eye tracking is investigated. The two interfaces can be complementary to attain improved performance. Especially to consider public availability, a low-cost interface device is intentionally used for test. A low-cost commercial EEG recording device is integrated with an inexpensive custom-built eye tracker. The developed hybrid interface is evaluated through target pointing and selection experiments. Eye movement is interpreted as cursor movement and noninvasive BCI selects a cursor point with two selection confirmation schemes. Using Fitts' law, the proposed interface scheme is compared with other interface schemes such as mouse, eye tracking with dwell time, and eye tracking with keyboard. In addition, the proposed hybrid BCI system is discussed with respect to a practical interface scheme. Although further advancement is required, the proposed hybrid BCI system has the potential to be practically useful in a natural and intuitive manner. PMID:25376041

  17. OCT-based crystalline lens topography in accommodating eyes

    PubMed Central

    Pérez-Merino, Pablo; Velasco-Ocana, Miriam; Martinez-Enriquez, Eduardo; Marcos, Susana

    2015-01-01

    Custom Spectral Domain Optical Coherence Tomography (SD-OCT) provided with automatic quantification and distortion correction algorithms was used to measure anterior and posterior crystalline lens surface elevation in accommodating eyes and to evaluate relationships between anterior segment surfaces. Nine young eyes were measured at different accommodative demands. Anterior and posterior lens radii of curvature decreased at a rate of 0.78 ± 0.18 and 0.13 ± 0.07 mm/D, anterior chamber depth decreased at 0.04 ± 0.01 mm/D and lens thickness increased at 0.04 ± 0.01 mm/D with accommodation. Three-dimensional surface elevations were estimated by subtracting best fitting spheres. In the relaxed state, the spherical term accounted for most of the surface irregularity in the anterior lens (47%) and astigmatism (70%) in the posterior lens. However, in accommodated lenses astigmatism was the predominant surface irregularity (90%) in the anterior lens. The RMS of high-order irregularities of the posterior lens surface was statistically significantly higher than that of the anterior lens surface (x2.02, p<0.0001). There was significant negative correlation in vertical coma (Z3−1) and oblique trefoil (Z3−3) between lens surfaces. The astigmatic angle showed high degree of alignment between corneal surfaces, moderate between corneal and anterior lens surface (~27 deg), but differed by ~80 deg between the anterior and posterior lens surfaces (including relative anterior/posterior lens astigmatic angle shifts (10-20 deg). PMID:26713216

  18. OCT-based crystalline lens topography in accommodating eyes.

    PubMed

    Pérez-Merino, Pablo; Velasco-Ocana, Miriam; Martinez-Enriquez, Eduardo; Marcos, Susana

    2015-12-01

    Custom Spectral Domain Optical Coherence Tomography (SD-OCT) provided with automatic quantification and distortion correction algorithms was used to measure anterior and posterior crystalline lens surface elevation in accommodating eyes and to evaluate relationships between anterior segment surfaces. Nine young eyes were measured at different accommodative demands. Anterior and posterior lens radii of curvature decreased at a rate of 0.78 ± 0.18 and 0.13 ± 0.07 mm/D, anterior chamber depth decreased at 0.04 ± 0.01 mm/D and lens thickness increased at 0.04 ± 0.01 mm/D with accommodation. Three-dimensional surface elevations were estimated by subtracting best fitting spheres. In the relaxed state, the spherical term accounted for most of the surface irregularity in the anterior lens (47%) and astigmatism (70%) in the posterior lens. However, in accommodated lenses astigmatism was the predominant surface irregularity (90%) in the anterior lens. The RMS of high-order irregularities of the posterior lens surface was statistically significantly higher than that of the anterior lens surface (x2.02, p<0.0001). There was significant negative correlation in vertical coma (Z3 (-1)) and oblique trefoil (Z3 (-3)) between lens surfaces. The astigmatic angle showed high degree of alignment between corneal surfaces, moderate between corneal and anterior lens surface (~27 deg), but differed by ~80 deg between the anterior and posterior lens surfaces (including relative anterior/posterior lens astigmatic angle shifts (10-20 deg). PMID:26713216

  19. Retinal Image-Based Eye-Tracking Using the Tracking Scanning Laser Ophthalmoscope

    NASA Astrophysics Data System (ADS)

    Sheehy, Christy Kathleen

    The tracking scanning laser ophthalmoscope (TSLO) was designed, built and characterized for high-resolution eye-tracking, imaging, and targeted retinal stimulus delivery. Eye-tracking is done via an image-based software program that monitors the image of the retina over time while simultaneously logging the displacements of the eye. Currently, this system is the most accurate, fast and functional eye-tracking system used in a standard ophthalmic instrument. The TSLO has the ability to non-invasively track the eye at 960 Hz (with an accuracy of 0.2 arcminutes or roughly 1 micron) and present stimuli to the retina at the resolution of single cone photoreceptors (0.66 arcminutes, which is roughly 3 microns). The combination of structural imaging and functional testing allows one to begin to more thoroughly understand retinal disease progression, as well probe specific retinal locations in order to test new treatment efficacies. This level of accuracy is unprecedented in the clinic and is crucial when monitoring minute changes in eye motion, structure, and function. Additionally, the system is capable of providing external eye-tracking for other high-resolution imaging systems, such as optical coherence tomography (OCT) and adaptive optics scanning laser ophthalmoscope (AOSLO) systems through the active steering of an imaging beam. This feature allows the imaging raster or stimuli to stay on target during fixational eye motion. This dissertation steps through all of the above-mentioned uses of the TSLO and further elaborates on the optimal design and system test performance capabilities of the system.

  20. Real-time distortion correction of fish-eye lens based on Bayer image signal

    NASA Astrophysics Data System (ADS)

    Lai, Shiming; Xiong, Zhihui; Chen, Lidong; Tan, Xin; Zhang, Maojun

    2014-03-01

    The imaging system based on a fish-eye lens generally has to correct the distortion of fish-eye images. The distortion correction based on the Bayer image signal is valuable, such as reducing the computation burden of image signal processing chips and providing a new imaging system structure of fish-eye lens. In this paper, a distortion correction method of fish-eye lens based on the Bayer image signal is proposed. Firstly, a distortion correction method that focuses on vertical straight lines and processing delay is proposed. Secondly, according to the correlation among color channels of the Bayer image, a novel Hermite interpolation method appropriate for Bayer image signal is proposed. Finally, a prototype system of fish-eye-lens-based imaging is established and the real-time field-programmable gate array (FPGA) implementation of the proposed method is demonstrated. The experiment demonstrates that the proposed distortion correction is not only characteristic of real-time processing and the smaller computation amount, but also applicable to embedded hardware.

  1. Gaze Stripes: Image-Based Visualization of Eye Tracking Data.

    PubMed

    Kurzhals, Kuno; Hlawatsch, Marcel; Heimerl, Florian; Burch, Michael; Ertl, Thomas; Weiskopf, Daniel

    2016-01-01

    We present a new visualization approach for displaying eye tracking data from multiple participants. We aim to show the spatio-temporal data of the gaze points in the context of the underlying image or video stimulus without occlusion. Our technique, denoted as gaze stripes, does not require the explicit definition of areas of interest but directly uses the image data around the gaze points, similar to thumbnails for images. A gaze stripe consists of a sequence of such gaze point images, oriented along a horizontal timeline. By displaying multiple aligned gaze stripes, it is possible to analyze and compare the viewing behavior of the participants over time. Since the analysis is carried out directly on the image data, expensive post-processing or manual annotation are not required. Therefore, not only patterns and outliers in the participants' scanpaths can be detected, but the context of the stimulus is available as well. Furthermore, our approach is especially well suited for dynamic stimuli due to the non-aggregated temporal mapping. Complementary views, i.e., markers, notes, screenshots, histograms, and results from automatic clustering, can be added to the visualization to display analysis results. We illustrate the usefulness of our technique on static and dynamic stimuli. Furthermore, we discuss the limitations and scalability of our approach in comparison to established visualization techniques. PMID:26529744

  2. Spatial Resolution Effects of Remote Sensing Informed Soil Nutrient Models Based on Landsat 8, RapidEye, WorldView-2 and GeoEye-1 Images

    NASA Astrophysics Data System (ADS)

    Xu, Y.; Grunwald, S.; Smith, S. E.; Abd-Elrahman, A.; Clingensmith, C. M.; Wani, S.

    2015-12-01

    Soil nutrient storage is essential and important to maintain food security and soil security in smallholder farm settings. The objective of this research was to analyze the spatial resolution effects of different remote sensing images on soil prediction models in Kothapally, India. We utilized Bayesian kriging (BK) to characterize the spatial pattern of total nitrogen (TN) and exchangeable potassium (Kex) in the topsoil (0-15 cm) at different spatial resolutions by incorporating spectral indices from Landsat 8 (30m), RapidEye (5m) and WorldView-2/GeoEye-1 images (2m). The band ratio of red to green, red to blue and green to blue, Crust Index and Atmospherically Resistant Vegetation Index from multiple images generally had high linear correlations with TN and Kex. The BK model of TN based on WorldView-2 and GeoEye-1 attained the highest model fit (R2=0.41) and lowest prediction error (RMSE=171.35 mg kg-1) compared with the BK models of TN based on Landsat 8 (R2=0.30; RMSE=182.26 mg kg-1) and RapidEye (R2=0.28; RMSE=183.52 mg kg-1). The BK model of Kex based on Landsat 8 had the highest model fit (R2=0.55) and the second lowest prediction error (RMSE=79.57 mg kg-1) compared with the BK models of Kex based on WorldView-2 and GeoEye-1 (R2=0.52; RMSE=79.42 mg kg-1) and RapidEye (R2=0.47; RMSE=83.91 mg kg-1). The lowest prediction fit and highest prediction error of soil TN and Kex models based on RapidEye suggest that the effect of fine spatial remote sensing spectral data inputs do not always lead to an increase of model fit. Soil maps based on WorldView-2 and GeoEye-1 have significant advantages in characterizing the variation of soil TN and Kex spatial pattern in smallholder farm settings compared with coarser maps. This research suggests that Digital Soil Mapping utilizing remote sensing spectral data from WorldView-2 and GeoEye-1 has high potential to be widely applied in smallholder farm settings and help smallholder farmers manage their soils and attain soil

  3. Online Learners' Reading Ability Detection Based on Eye-Tracking Sensors.

    PubMed

    Zhan, Zehui; Zhang, Lei; Mei, Hu; Fong, Patrick S W

    2016-01-01

    The detection of university online learners' reading ability is generally problematic and time-consuming. Thus the eye-tracking sensors have been employed in this study, to record temporal and spatial human eye movements. Learners' pupils, blinks, fixation, saccade, and regression are recognized as primary indicators for detecting reading abilities. A computational model is established according to the empirical eye-tracking data, and applying the multi-feature regularization machine learning mechanism based on a Low-rank Constraint. The model presents good generalization ability with an error of only 4.9% when randomly running 100 times. It has obvious advantages in saving time and improving precision, with only 20 min of testing required for prediction of an individual learner's reading ability. PMID:27626418

  4. Prior Knowledge and Online Inquiry-Based Science Reading: Evidence from Eye Tracking

    ERIC Educational Resources Information Center

    Ho, Hsin Ning Jessie; Tsai, Meng-Jung; Wang, Ching-Yeh; Tsai, Chin-Chung

    2014-01-01

    This study employed eye-tracking technology to examine how students with different levels of prior knowledge process text and data diagrams when reading a web-based scientific report. Students' visual behaviors were tracked and recorded when they read a report demonstrating the relationship between the greenhouse effect and global climate…

  5. Automatic system for 3D reconstruction of the chick eye based on digital photographs.

    PubMed

    Wong, Alexander; Genest, Reno; Chandrashekar, Naveen; Choh, Vivian; Irving, Elizabeth L

    2012-01-01

    The geometry of anatomical specimens is very complex and accurate 3D reconstruction is important for morphological studies, finite element analysis (FEA) and rapid prototyping. Although magnetic resonance imaging, computed tomography and laser scanners can be used for reconstructing biological structures, the cost of the equipment is fairly high and specialised technicians are required to operate the equipment, making such approaches limiting in terms of accessibility. In this paper, a novel automatic system for 3D surface reconstruction of the chick eye from digital photographs of a serially sectioned specimen is presented as a potential cost-effective and practical alternative. The system is designed to allow for automatic detection of the external surface of the chick eye. Automatic alignment of the photographs is performed using a combination of coloured markers and an algorithm based on complex phase order likelihood that is robust to noise and illumination variations. Automatic segmentation of the external boundaries of the eye from the aligned photographs is performed using a novel level-set segmentation approach based on a complex phase order energy functional. The extracted boundaries are sampled to construct a 3D point cloud, and a combination of Delaunay triangulation and subdivision surfaces is employed to construct the final triangular mesh. Experimental results using digital photographs of the chick eye show that the proposed system is capable of producing accurate 3D reconstructions of the external surface of the eye. The 3D model geometry is similar to a real chick eye and could be used for morphological studies and FEA. PMID:21181572

  6. An integrated Mach-Zehnder modulator bias controller based on eye-amplitude monitoring

    NASA Astrophysics Data System (ADS)

    Kim, Min-Hyeong; Jung, Hyun-Yong; Zimmermann, Lars; Choi, Woo-Young

    2016-03-01

    A novel integrated Mach-Zehnder modulator (MZM) bias controller based on eye-amplitude monitoring is demonstrated in IHP's 0.25-μm BiCMOS technology. The bias controller monitors the MZM output light, automatically moves the MZM bias voltage to the optimal value that produces the largest eye amplitude, and maintains it there even if the MZM transfer characteristics change due to thermal drift. The controller is based on the feedback loop consisting of Si photodetector, trans-impedance amplifier, rectifier, square amplifier, track-and-hold circuit, comparator, polarity changer, and charge-pump, all of which are monolithically integrated. The area of the controller is 0.083-mm2 and it consumes 92.5-mW. Our bias controller shows successful operation for a commercially-available 850-nm LiNbO3 MZM modulated with 3-Gbps PRBS data by maintaining a very clean eye for at least 30 minutes. Without the controller, the eye for the same MZM modulation becomes completely closed due to thermal drift. The data rate is limited by the Si PD integrated in the controller not by the controller architecture. Since our controller is based on the Si BiCMOS technology which can also provide integrated Si photonics devices on the same Si, it has a great potential for realizing a Si MZM with an integrated bias controller, which should fully demonstrate the advantage of electronic-photonic integrated circuit technology.

  7. A Field Test of Web-Based Screening for Dry Eye Disease to Enhance Awareness of Eye Problems Among General Internet Users: A Latent Strategy to Promote Health

    PubMed Central

    Uchino, Miki; Kawazoe, Takashi; Kamiyashiki, Masaaki; Sano, Kokoro; Tsubota, Kazuo

    2013-01-01

    Background A Web-based self-check system including a brief questionnaire would seem to be a suitable tool for rapid disease screening. Objective The purpose of this preliminary study was to test a Web-based self-screening questionnaire for drawing attention to dry eye disease among general Internet users and identifying those with a higher risk of developing the condition. Methods A survey website was launched and used to recruit participants from general Internet users. In the first phase, volunteers were asked to complete a Web-based self-screening questionnaire containing 12 questions on dry eye symptoms. The second phase focused on the respondents who reported five or more dry eye symptoms and expressed their intention to seek medical attention. These participants performed the Schirmer test, for evaluating tear production, and completed a paper-based lifestyle questionnaire to provide relevant background data. Results Of the 1689 visitors to the website, 980 (58.0%) volunteers completed the Web-based self-screening questionnaire. Among these, 355 (36.2%) respondents reported five or more dry eye symptoms. Then, 99 (27.9%) of the symptomatic participants performed the Schirmer test and completed the paper-based lifestyle questionnaire. Out of these, 32 (32.2%) had abnormal tear production (≤5 mm). Conclusions The proposed Web-based self-screening questionnaire seems to be a promising tool for raising awareness of dry eye disease among general Internet users and identifying those with a higher risk of developing the condition, although further research is needed to validate its effectiveness. PMID:24072379

  8. Gaze Estimation for Off-Angle Iris Recognition Based on the Biometric Eye Model

    SciTech Connect

    Karakaya, Mahmut; Barstow, Del R; Santos-Villalobos, Hector J; Thompson, Joseph W; Bolme, David S; Boehnen, Chris Bensing

    2013-01-01

    Iris recognition is among the highest accuracy biometrics. However, its accuracy relies on controlled high quality capture data and is negatively affected by several factors such as angle, occlusion, and dilation. Non-ideal iris recognition is a new research focus in biometrics. In this paper, we present a gaze estimation method designed for use in an off-angle iris recognition framework based on the ANONYMIZED biometric eye model. Gaze estimation is an important prerequisite step to correct an off-angle iris images. To achieve the accurate frontal reconstruction of an off-angle iris image, we first need to estimate the eye gaze direction from elliptical features of an iris image. Typically additional information such as well-controlled light sources, head mounted equipment, and multiple cameras are not available. Our approach utilizes only the iris and pupil boundary segmentation allowing it to be applicable to all iris capture hardware. We compare the boundaries with a look-up-table generated by using our biologically inspired biometric eye model and find the closest feature point in the look-up-table to estimate the gaze. Based on the results from real images, the proposed method shows effectiveness in gaze estimation accuracy for our biometric eye model with an average error of approximately 3.5 degrees over a 50 degree range.

  9. Research on the image fusion and target extraction based on bionic compound eye system

    NASA Astrophysics Data System (ADS)

    Zhang, Shaowei; Hao, Qun; Song, Yong; Wang, Zihan; Zhang, Kaiyu; Zhang, Shiyu

    2015-08-01

    People attach more and more importance to bionic compound eye due to its advantages such as small volume, large field of view and sensitivity to high-speed moving objects. Small field of view and large volume are the disadvantages of traditional image sensor and in order to avoid these defects, this paper intends to build a set of compound eye system based on insect compound eye structure and visual processing mechanism. In the center of this system is the primary sensor which has high resolution ratio. The primary sensor is surrounded by the other six sensors which have low resolution ratio. Based on this system, this paper will study the target image fusion and extraction method by using plane compound eye structure. This paper designs a control module which can combine the distinguishing features of high resolution image with local features of low resolution image so as to conduct target detection, recognition and location. Compared with traditional ways, the way of high resolution in the center and low resolution around makes this system own the advantages of high resolution and large field of view and enables the system to detect the object quickly and recognize the object accurately.

  10. Gaze estimation for off-angle iris recognition based on the biometric eye model

    NASA Astrophysics Data System (ADS)

    Karakaya, Mahmut; Barstow, Del; Santos-Villalobos, Hector; Thompson, Joseph; Bolme, David; Boehnen, Christopher

    2013-05-01

    Iris recognition is among the highest accuracy biometrics. However, its accuracy relies on controlled high quality capture data and is negatively affected by several factors such as angle, occlusion, and dilation. Non-ideal iris recognition is a new research focus in biometrics. In this paper, we present a gaze estimation method designed for use in an off-angle iris recognition framework based on the ORNL biometric eye model. Gaze estimation is an important prerequisite step to correct an off-angle iris images. To achieve the accurate frontal reconstruction of an off-angle iris image, we first need to estimate the eye gaze direction from elliptical features of an iris image. Typically additional information such as well-controlled light sources, head mounted equipment, and multiple cameras are not available. Our approach utilizes only the iris and pupil boundary segmentation allowing it to be applicable to all iris capture hardware. We compare the boundaries with a look-up-table generated by using our biologically inspired biometric eye model and find the closest feature point in the look-up-table to estimate the gaze. Based on the results from real images, the proposed method shows effectiveness in gaze estimation accuracy for our biometric eye model with an average error of approximately 3.5 degrees over a 50 degree range.

  11. Eye Infections

    MedlinePlus

    Your eyes can get infections from bacteria, fungi, or viruses. Eye infections can occur in different parts of the eye and can affect just one eye or both. Two common eye infections are Conjunctivitis - also known as pinkeye. Conjunctivitis is ...

  12. From neural-based object recognition toward microelectronic eyes

    NASA Technical Reports Server (NTRS)

    Sheu, Bing J.; Bang, Sa Hyun

    1994-01-01

    Engineering neural network systems are best known for their abilities to adapt to the changing characteristics of the surrounding environment by adjusting system parameter values during the learning process. Rapid advances in analog current-mode design techniques have made possible the implementation of major neural network functions in custom VLSI chips. An electrically programmable analog synapse cell with large dynamic range can be realized in a compact silicon area. New designs of the synapse cells, neurons, and analog processor are presented. A synapse cell based on Gilbert multiplier structure can perform the linear multiplication for back-propagation networks. A double differential-pair synapse cell can perform the Gaussian function for radial-basis network. The synapse cells can be biased in the strong inversion region for high-speed operation or biased in the subthreshold region for low-power operation. The voltage gain of the sigmoid-function neurons is externally adjustable which greatly facilitates the search of optimal solutions in certain networks. Various building blocks can be intelligently connected to form useful industrial applications. Efficient data communication is a key system-level design issue for large-scale networks. We also present analog neural processors based on perceptron architecture and Hopfield network for communication applications. Biologically inspired neural networks have played an important role towards the creation of powerful intelligent machines. Accuracy, limitations, and prospects of analog current-mode design of the biologically inspired vision processing chips and cellular neural network chips are key design issues.

  13. NGS-based Molecular diagnosis of 105 eyeGENE® probands with Retinitis Pigmentosa

    PubMed Central

    Ge, Zhongqi; Bowles, Kristen; Goetz, Kerry; Scholl, Hendrik P. N.; Wang, Feng; Wang, Xinjing; Xu, Shan; Wang, Keqing; Wang, Hui; Chen, Rui

    2015-01-01

    The National Ophthalmic Disease Genotyping and Phenotyping Network (eyeGENE®) was established in an effort to facilitate basic and clinical research of human inherited eye disease. In order to provide high quality genetic testing to eyeGENE®’s enrolled patients which potentially aids clinical diagnosis and disease treatment, we carried out a pilot study and performed Next-generation sequencing (NGS) based molecular diagnosis for 105 Retinitis Pigmentosa (RP) patients randomly selected from the network. A custom capture panel was designed, which incorporated 195 known retinal disease genes, including 61 known RP genes. As a result, disease-causing mutations were identified in 52 out of 105 probands (solving rate of 49.5%). A total of 82 mutations were identified, and 48 of them were novel. Interestingly, for three probands the molecular diagnosis was inconsistent with the initial clinical diagnosis, while for five probands the molecular information suggested a different inheritance model other than that assigned by the physician. In conclusion, our study demonstrated that NGS target sequencing is efficient and sufficiently precise for molecular diagnosis of a highly heterogeneous patient cohort from eyeGENE®. PMID:26667666

  14. MEMS scanner mirror based system for retina scanning and in eye projection

    NASA Astrophysics Data System (ADS)

    Woittennek, Franziska; Knobbe, Jens; Pügner, Tino; Dallmann, Hans-Georg; Schelinski, Uwe; Grüger, Heinrich

    2015-02-01

    Many applications could benefit from miniaturized systems to scan blood vessels behind the retina in the human eye, so called "retina scanning". This reaches from access control to sophisticated security applications and medical devices. High volume systems for consumer applications require low cost and a user friendly operation. For example this includes no need for removal of glasses and self-adjustment, in turn guidance of focus and point of attraction by simultaneous projection for the user. A new system has been designed based on the well-known resonantly driven 2-d scanner mirror of Fraunhofer IPMS. A combined NIR and VIS laser system illuminates the eye through an eye piece designed for an operating distance allowing the use of glasses and granting sufficient field of view. This usability feature was considered to be more important than highest miniaturization. The modulated VIS laser facilitates the projection of an image directly onto the retina. The backscattered light from the continuous NIR laser contains the information of the blood vessels and is detected by a highly sensitive photo diode. A demonstrational setup has been realized including readout and driving electronics. The laser power was adjusted to an eye-secure level. Additional security features were integrated. Test measurements revealed promising results. In a first demonstration application the detection of biometric pattern of the blood vessels was evaluated for issues authentication in.

  15. Image-Based Grouping during Binocular Rivalry Is Dictated by Eye-Of-Origin

    PubMed Central

    Stuit, Sjoerd M.; Paffen, Chris L. E.; van der Smagt, Maarten J.; Verstraten, Frans A. J.

    2014-01-01

    Prolonged viewing of dichoptically presented images with different content results in perceptual alternations known as binocular rivalry. This phenomenon is thought to be the result of competition at a local level, where local rivalry zones interact to give rise to a single, global dominant percept. Certain perceived combinations that result from this local competition are known to last longer than others, which is referred to as grouping during binocular rivalry. In recent years, the phenomenon has been suggested to be the result of competition at both eye- and image-based processing levels, although the exact contribution from each level remains elusive. Here we use a paradigm designed specifically to quantify the contribution of eye- and image-based processing to grouping during rivalry. In this paradigm we used sine-wave gratings as well as upright and inverted faces, with and without binocular disparity-based occlusion. These stimuli and conditions were used because they are known to result in processing at different stages throughout the visual processing hierarchy. Specifically, more complex images were included in order to maximize the potential contribution of image-based grouping. In spite of this, our results show that increasing image complexity did not lead to an increase in the contribution of image-based processing to grouping during rivalry. In fact, the results show that grouping was primarily affected by the eye-of-origin of the image parts, irrespective of stimulus type. We suggest that image content affects grouping during binocular rivalry at low-level processing stages, where it is intertwined with eye-of-origin information. PMID:24987847

  16. Spectral optimization simulation of white light based on the photopic eye-sensitivity curve

    NASA Astrophysics Data System (ADS)

    Dai, Qi; Hao, Luoxi; Lin, Yi; Cui, Zhe

    2016-02-01

    Spectral optimization simulation of white light is studied to boost maximum attainable luminous efficacy of radiation at high color-rendering index (CRI) and various color temperatures. The photopic eye-sensitivity curve V(λ) is utilized as the dominant portion of white light spectra. Emission spectra of a blue InGaN light-emitting diode (LED) and a red AlInGaP LED are added to the spectrum of V(λ) to match white color coordinates. It is demonstrated that at the condition of color temperature from 2500 K to 6500 K and CRI above 90, such white sources can achieve spectral efficacy of 330-390 lm/W, which is higher than the previously reported theoretical maximum values. We show that this eye-sensitivity-based approach also has advantages on component energy conversion efficiency compared with previously reported optimization solutions.

  17. A paper-based cantilever array sensor: Monitoring volatile organic compounds with naked eye.

    PubMed

    Fraiwan, Arwa; Lee, Hankeun; Choi, Seokheun

    2016-09-01

    Volatile organic compound (VOC) detection is critical for controlling industrial and commercial emissions, environmental monitoring, and public health. Simple, portable, rapid and low-cost VOC sensing platforms offer the benefits of on-site and real-time monitoring anytime and anywhere. The best and most practically useful approaches to monitoring would include equipment-free and power-free detection by the naked eye. In this work, we created a novel, paper-based cantilever sensor array that allows simple and rapid naked-eye VOC detection without the need for power, electronics or readout interface/equipment. This simple VOC detection method was achieved using (i) low-cost paper materials as a substrate and (ii) swellable thin polymers adhered to the paper. Upon exposure to VOCs, the polymer swelling adhered to the paper-based cantilever, inducing mechanical deflection that generated a distinctive composite pattern of the deflection angles for a specific VOC. The angle is directly measured by the naked eye on a 3-D protractor printed on a paper facing the cantilevers. The generated angle patterns are subjected to statistical algorithms (linear discriminant analysis (LDA)) to classify each VOC sample and selectively detect a VOC. We classified four VOC samples with 100% accuracy using LDA. PMID:27343578

  18. Eye redness

    MedlinePlus

    Bloodshot eyes; Red eyes; Scleral infection; Conjunctival infection ... There are many causes of a red eye or eyes. Some are medical emergencies and some are a cause for concern, but not an emergency. Others are nothing to worry about. ...

  19. Eye Cancer

    MedlinePlus

    ... Eye Cancer - Overview Request Permissions Print to PDF Eye Cancer - Overview Approved by the Cancer.Net Editorial Board , ... Cancer Research and Advocacy Survivorship Blog About Us Eye Cancer Guide Cancer.Net Guide Eye Cancer Overview Statistics ...

  20. Eye emergencies

    MedlinePlus

    ... Trauma A black eye is usually caused by direct trauma to the eye or face. The bruise ... can cause bruising around the eyes, even without direct injury to the eye. Sometimes, serious damage to ...

  1. Eye pain

    MedlinePlus

    Ophthalmalgia; Pain - eye ... Pain in the eye can be an important symptom of a health problem. Make sure you tell your health care provider if you have eye pain that does not go away. Tired eyes or ...

  2. An eye movement based reading intervention in lexical and segmental readers with acquired dyslexia.

    PubMed

    Ablinger, Irene; von Heyden, Kerstin; Vorstius, Christian; Halm, Katja; Huber, Walter; Radach, Ralph

    2014-01-01

    Due to their brain damage, aphasic patients with acquired dyslexia often rely to a greater extent on lexical or segmental reading procedures. Thus, therapy intervention is mostly targeted on the more impaired reading strategy. In the present work we introduce a novel therapy approach based on real-time measurement of patients' eye movements as they attempt to read words. More specifically, an eye movement contingent technique of stepwise letter de-masking was used to support sequential reading, whereas fixation-dependent initial masking of non-central letters stimulated a lexical (parallel) reading strategy. Four lexical and four segmental readers with acquired central dyslexia received our intensive reading intervention. All participants showed remarkable improvements as evident in reduced total reading time, a reduced number of fixations per word and improved reading accuracy. Both types of intervention led to item-specific training effects in all subjects. A generalisation to untrained items was only found in segmental readers after the lexical training. Eye movement analyses were also used to compare word processing before and after therapy, indicating that all patients, with one exclusion, maintained their preferred reading strategy. However, in several cases the balance between sequential and lexical processing became less extreme, indicating a more effective individual interplay of both word processing routes. PMID:24813563

  3. Assessing visual attention using eye tracking sensors in intelligent cognitive therapies based on serious games.

    PubMed

    Frutos-Pascual, Maite; Garcia-Zapirain, Begonya

    2015-01-01

    This study examines the use of eye tracking sensors as a means to identify children's behavior in attention-enhancement therapies. For this purpose, a set of data collected from 32 children with different attention skills is analyzed during their interaction with a set of puzzle games. The authors of this study hypothesize that participants with better performance may have quantifiably different eye-movement patterns from users with poorer results. The use of eye trackers outside the research community may help to extend their potential with available intelligent therapies, bringing state-of-the-art technologies to users. The use of gaze data constitutes a new information source in intelligent therapies that may help to build new approaches that are fully-customized to final users' needs. This may be achieved by implementing machine learning algorithms for classification. The initial study of the dataset has proven a 0.88 (±0.11) classification accuracy with a random forest classifier, using cross-validation and hierarchical tree-based feature selection. Further approaches need to be examined in order to establish more detailed attention behaviors and patterns among children with and without attention problems. PMID:25985158

  4. Assessing Visual Attention Using Eye Tracking Sensors in Intelligent Cognitive Therapies Based on Serious Games

    PubMed Central

    Frutos-Pascual, Maite; Garcia-Zapirain, Begonya

    2015-01-01

    This study examines the use of eye tracking sensors as a means to identify children's behavior in attention-enhancement therapies. For this purpose, a set of data collected from 32 children with different attention skills is analyzed during their interaction with a set of puzzle games. The authors of this study hypothesize that participants with better performance may have quantifiably different eye-movement patterns from users with poorer results. The use of eye trackers outside the research community may help to extend their potential with available intelligent therapies, bringing state-of-the-art technologies to users. The use of gaze data constitutes a new information source in intelligent therapies that may help to build new approaches that are fully-customized to final users' needs. This may be achieved by implementing machine learning algorithms for classification. The initial study of the dataset has proven a 0.88 (±0.11) classification accuracy with a random forest classifier, using cross-validation and hierarchical tree-based feature selection. Further approaches need to be examined in order to establish more detailed attention behaviors and patterns among children with and without attention problems. PMID:25985158

  5. A practical efficient human computer interface based on saccadic eye movements for people with disabilities.

    PubMed

    Soltani, Sima; Mahnam, Amin

    2016-03-01

    Human computer interfaces (HCI) provide new channels of communication for people with severe motor disabilities to state their needs, and control their environment. Some HCI systems are based on eye movements detected from the electrooculogram. In this study, a wearable HCI, which implements a novel adaptive algorithm for detection of saccadic eye movements in eight directions, was developed, considering the limitations that people with disabilities have. The adaptive algorithm eliminated the need for calibration of the system for different users and in different environments. A two-stage typing environment and a simple game for training people with disabilities to work with the system were also developed. Performance of the system was evaluated in experiments with the typing environment performed by six participants without disabilities. The average accuracy of the system in detecting eye movements and blinking was 82.9% at first tries with an average typing rate of 4.5cpm. However an experienced user could achieve 96% accuracy and 7.2cpm typing rate. Moreover, the functionality of the system for people with movement disabilities was evaluated by performing experiments with the game environment. Six people with tetraplegia and significant levels of speech impairment played with the computer game several times. The average success rate in performing the necessary eye movements was 61.5%, which increased significantly with practice up to 83% for one participant. The developed system is 2.6×4.5cm in size and weighs only 15g, assuring high level of comfort for the users. PMID:26848728

  6. Eye tracker.

    PubMed

    Pruehsner, W; Enderle, J D

    1999-01-01

    A device that records saccadic eye movements, the Eye Tracker, is presented in this paper. The Eye Tracker utilizes infra-red technology mounted on fully adjustable goggles to follow eye movements targeted by either a goggles mounted HUD type display or a wall mounted light bank. Output from the goggles is remotely sent to a PC type computer, which leads to device portability. The goggles can also maintain output data in an internal memory for latter download. The user interface is Windows based with the output from the goggles represented as a trace map or plotted points. This output can also be saved or printed for future reference. The user interface can be used on any PC type computer. The device is designed with reference to standard ISO design methodology. Safety in design and final product usage has also been addressed with reference to standard ISO type procedures. Device accuracy is maintained by precise construction of the IR units in the goggles and tight control of cross talk between each IR device plus filtering of ambient light signals. Also, a reset feature is included to maintain equal baseline control. An automatic switching device is included in the goggles to allow the Eye Tracker to "warm up," assuring that equal IR power is delivered for each subject tested. The IR units in the goggles are also modular in case replacement is required. PMID:11143354

  7. Neural-Net-Based Predictive Modeling of Spout Eye Size in Steelmaking

    NASA Astrophysics Data System (ADS)

    Palaneeswaran, Ekambaram; Brooks, Geoffrey; Xu, Xiaodong Bernard

    2012-06-01

    Gas stirring is commonly used in pyrometallurgical vessels to enhance mass and heat transfer and to promote impurity removal. In the case of secondary steelmaking, the spout eye area is caused by the escape of the gas from the top of the smelt where the liquid steel is directly exposed to the air, and oxygen can be picked up through the spout eye area that can reduce the quality of steel. Thus, controlling the size of the spout eye area is very important to improving the quality of the steel and to keeping the consistency of the product. The set of prevailing models to predict spout eye size are based on specific practically difficult variables, e.g., height of slag in hot upper layer of vessels and gas flow rate at nozzle exit. Recently, the cold model results showed that the stirring process can be conveniently monitored by the signals such as (1) the image signal from the top of the vessel, (2) the sound of the stirring process, and (3) the vibration on the wall of the vessel. This article outlines the key details of a novel research investigation using neural-network-based predictive modeling such as general regression neural networks (GRNN) with genetic adaptive calibrations. Predictive capacities and generalization potentials of five model constructs ( i.e., with different sets of input parameters) were explored, and the neural net modeling yielded encouraging outcomes, e.g., (1) excellent goodness-of-fit generalization measures including high values of correlation and R 2 validation parameters ( e.g., r = 0.921 and R 2 = 0.845 in a model validation), and (2) low values of root mean square of errors ( e.g., 3.034). Overall, the research outlined in this article demonstrates that the spout eye size can be effectively predicted by predictive neural net modeling with convenient and practically measurable variables such as sound and vibration observations on the steelmaking vessels. These results have only been demonstrated for a cold model of the process, and

  8. Development of a cyclodextrin-based aqueous cyclosporin A eye drop formulations.

    PubMed

    Jóhannsdóttir, Sunna; Jansook, Phatsawee; Stefánsson, Einar; Loftsson, Thorsteinn

    2015-09-30

    Cyclosporin A (CyA) is a lipophilic, cyclic polypeptide drug with anti-inflammatory properties. It is used in topical treatment of dry eyes and is now commercially available in oil based surfactant containing eye drops. Surfactants can irritate the eye surface causing burning, itching and irritation of the conjunctiva, and oil-based drops can result in blurred vision. Thus, the aim of this study was to develop surfactant free aqueous 0.05% (w/v) CyA eye drops where the drug is present in an aqueous vehicle containing CyA/cyclodextrin (CyA/CD) nanoparticles. The effects of the natural α-, β- and γ-cyclodextrins (αCD, βCD and γCD), as well as of the water soluble hydroxypropyl derivatives of γCD and αCD (HPγCD, HPαCD) and randomly methylated βCD (RMβCD), were determined in pure water. αCD had the best solubilizing effect increasing the solubility of CyA above 0.05% upon addition of only 5% (w/v) αCD. γCD did not have as good solubilizing effect but was tested further due to its superior ability to form nanoparticles and its favorable toxicological profile. Seven eye drop formulations were prepared and tested. All contained 0.05% (w/v) CyA in addition to polyvinyl alcohol, benzalkonium chloride, disodium edetate and various amounts of CD (αCD, γCD and mixtures thereof). When the formulation contained only αCD most of the drug was dissolved but some small aggregates were formed with hydrodynamic diameter of about 6 and 155 nm. When the formulation contained only γCD negligible CyA/CD complexation occurred with most of the drug present as solid CyA particles. When the formulation contained a mixture of αCD and γCD, where αCD concentration was at least 3% (w/v), the entire drug content was dissolved in the media under formation of relatively large (100-2000 nm) CyA/CD nanoparticles. αCD solubilized the drug while γCD enhanced nanoparticle formation. The effect of polyvinyl alcohol, benzalkonium chloride and disodium edetate on the nanoparticle

  9. Collaborative EDNAP exercise on the IrisPlex system for DNA-based prediction of human eye colour.

    PubMed

    Chaitanya, Lakshmi; Walsh, Susan; Andersen, Jeppe Dyrberg; Ansell, Ricky; Ballantyne, Kaye; Ballard, David; Banemann, Regine; Bauer, Christiane Maria; Bento, Ana Margarida; Brisighelli, Francesca; Capal, Tomas; Clarisse, Lindy; Gross, Theresa E; Haas, Cordula; Hoff-Olsen, Per; Hollard, Clémence; Keyser, Christine; Kiesler, Kevin M; Kohler, Priscila; Kupiec, Tomasz; Linacre, Adrian; Minawi, Anglika; Morling, Niels; Nilsson, Helena; Norén, Lina; Ottens, Renée; Palo, Jukka U; Parson, Walther; Pascali, Vincenzo L; Phillips, Chris; Porto, Maria João; Sajantila, Antti; Schneider, Peter M; Sijen, Titia; Söchtig, Jens; Syndercombe-Court, Denise; Tillmar, Andreas; Turanska, Martina; Vallone, Peter M; Zatkalíková, Lívia; Zidkova, Anastassiya; Branicki, Wojciech; Kayser, Manfred

    2014-07-01

    The IrisPlex system is a DNA-based test system for the prediction of human eye colour from biological samples and consists of a single forensically validated multiplex genotyping assay together with a statistical prediction model that is based on genotypes and phenotypes from thousands of individuals. IrisPlex predicts blue and brown human eye colour with, on average, >94% precision accuracy using six of the currently most eye colour informative single nucleotide polymorphisms (HERC2 rs12913832, OCA2 rs1800407, SLC24A4 rs12896399, SLC45A2 (MATP) rs16891982, TYR rs1393350, and IRF4 rs12203592) according to a previous study, while the accuracy in predicting non-blue and non-brown eye colours is considerably lower. In an effort to vigorously assess the IrisPlex system at the international level, testing was performed by 21 laboratories in the context of a collaborative exercise divided into three tasks and organised by the European DNA Profiling (EDNAP) Group of the International Society of Forensic Genetics (ISFG). Task 1 involved the assessment of 10 blood and saliva samples provided on FTA cards by the organising laboratory together with eye colour phenotypes; 99.4% of the genotypes were correctly reported and 99% of the eye colour phenotypes were correctly predicted. Task 2 involved the assessment of 5 DNA samples extracted by the host laboratory from simulated casework samples, artificially degraded, and provided to the participants in varying DNA concentrations. For this task, 98.7% of the genotypes were correctly determined and 96.2% of eye colour phenotypes were correctly inferred. For Tasks 1 and 2 together, 99.2% (1875) of the 1890 genotypes were correctly generated and of the 15 (0.8%) incorrect genotype calls, only 2 (0.1%) resulted in incorrect eye colour phenotypes. The voluntary Task 3 involved participants choosing their own test subjects for IrisPlex genotyping and eye colour phenotype inference, while eye photographs were provided to the organising

  10. Naked-eye quantitative aptamer-based assay on paper device.

    PubMed

    Zhang, Yun; Gao, Dong; Fan, Jinlong; Nie, Jinfang; Le, Shangwang; Zhu, Wenyuan; Yang, Jiani; Li, Jianping

    2016-04-15

    This work initially describes the design of low-cost, naked-eye quantitative aptamer-based assays by using microfluidic paper-based analytical device (μPAD). Two new detection motifs are proposed for quantitative μPAD measurement without using external electronic readers, which depend on the length of colored region in a strip-like μPAD and the number of colorless detection microzones in a multi-zone μPAD. The length measuring method is based on selective color change of paper from colorless to blue-black via formation of iodine-starch complex. The counting method is conducted on the basis of oxidation-reduction reaction between hydrogen peroxide and potassium permanganate. Their utility is well demonstrated with sensitive, specific detection of adenosine as a model analyte with the naked eye in buffer samples and undiluted human serum. These equipment-free quantitative methods proposed thus hold great potential for the development of more aptamer-based assays that are simple, cost-efficient, portable, and user-friendly for various point-of-care applications particularly in resource-constrained environments. PMID:26684676

  11. Dew inspired breathing-based detection of genetic point mutation visualized by naked eye

    NASA Astrophysics Data System (ADS)

    Xie, Liping; Wang, Tongzhou; Huang, Tianqi; Hou, Wei; Huang, Guoliang; Du, Yanan

    2014-09-01

    A novel label-free method based on breathing-induced vapor condensation was developed for detection of genetic point mutation. The dew-inspired detection was realized by integration of target-induced DNA ligation with rolling circle amplification (RCA). The vapor condensation induced by breathing transduced the RCA-amplified variances in DNA contents into visible contrast. The image could be recorded by a cell phone for further or even remote analysis. This green assay offers a naked-eye-reading method potentially applied for point-of-care liver cancer diagnosis in resource-limited regions.

  12. Dew inspired breathing-based detection of genetic point mutation visualized by naked eye

    PubMed Central

    Xie, Liping; Wang, Tongzhou; Huang, Tianqi; Hou, Wei; Huang, Guoliang; Du, Yanan

    2014-01-01

    A novel label-free method based on breathing-induced vapor condensation was developed for detection of genetic point mutation. The dew-inspired detection was realized by integration of target-induced DNA ligation with rolling circle amplification (RCA). The vapor condensation induced by breathing transduced the RCA-amplified variances in DNA contents into visible contrast. The image could be recorded by a cell phone for further or even remote analysis. This green assay offers a naked-eye-reading method potentially applied for point-of-care liver cancer diagnosis in resource-limited regions. PMID:25199907

  13. Machine vision based on the concept of contrast sensitivity of the human eye

    NASA Astrophysics Data System (ADS)

    Bezzubik, Vitali; Belashenkov, Nikolai; Vdovin, Gleb

    2014-09-01

    The model of contrast sensitivity function (CSF) of machine vision system, based on the CSF of the human visual system is proposed. By analogy with the human eye, we employ the concept of ganglion cell receptive field to the artificial light-sensitive elements. By further following this concept, we introduced quantative metrics of local and global contrast of digital image. We suggested that the contrast sensitivity threshold forms an iso-line in the parameter space contrast - spatial frequency. The model, implemented in a computer vision system, has been compared to the results of contrast sensitivity research, conducted directly with the human visual system, and demonstrated a good match.

  14. A Fuzzy-Based Fusion Method of Multimodal Sensor-Based Measurements for the Quantitative Evaluation of Eye Fatigue on 3D Displays

    PubMed Central

    Bang, Jae Won; Choi, Jong-Suk; Heo, Hwan; Park, Kang Ryoung

    2015-01-01

    With the rapid increase of 3-dimensional (3D) content, considerable research related to the 3D human factor has been undertaken for quantitatively evaluating visual discomfort, including eye fatigue and dizziness, caused by viewing 3D content. Various modalities such as electroencephalograms (EEGs), biomedical signals, and eye responses have been investigated. However, the majority of the previous research has analyzed each modality separately to measure user eye fatigue. This cannot guarantee the credibility of the resulting eye fatigue evaluations. Therefore, we propose a new method for quantitatively evaluating eye fatigue related to 3D content by combining multimodal measurements. This research is novel for the following four reasons: first, for the evaluation of eye fatigue with high credibility on 3D displays, a fuzzy-based fusion method (FBFM) is proposed based on the multimodalities of EEG signals, eye blinking rate (BR), facial temperature (FT), and subjective evaluation (SE); second, to measure a more accurate variation of eye fatigue (before and after watching a 3D display), we obtain the quality scores of EEG signals, eye BR, FT and SE; third, for combining the values of the four modalities we obtain the optimal weights of the EEG signals BR, FT and SE using a fuzzy system based on quality scores; fourth, the quantitative level of the variation of eye fatigue is finally obtained using the weighted sum of the values measured by the four modalities. Experimental results confirm that the effectiveness of the proposed FBFM is greater than other conventional multimodal measurements. Moreover, the credibility of the variations of the eye fatigue using the FBFM before and after watching the 3D display is proven using a t-test and descriptive statistical analysis using effect size. PMID:25961382

  15. SU-E-I-37: Eye Lens Dose Reduction From CT Scan Using Organ Based Tube Current Modulation

    SciTech Connect

    Liu, H; Liu, T; Xu, X; Wu, J; Zhuo, W

    2015-06-15

    Purpose: To investigate the eye lens dose reduction by CT scan with organ based tube current modulation (OBTCM) using GPU Monte Carlo code ARCHER-CT. Methods: 36 X-ray sources and bowtie filters were placed around the patient head with the projection angle interval of 10° for one rotation of CT scan, each projection was simulated respectively. The voxel eye models with high resolution(0.1mm*0.1mm*0.1mm) were used in the simulation and different tube voltage including 80kVp, 100kVp, 120kVp and 140kVp were taken into consideration. Results: The radiation doses to the eye lens increased with the tube voltage raised from 80kVp to 140kVp, and the dose results from 0° (AP) direction are much higher than those from 180° (PA) direction for all the 4 different tube voltage investigated. This 360° projection dose characteristic enables organ based TCM, which can reduce the eye lens dose by more than 55%. Conclusion: As the eye lens belongs to superficial tissues, its radiation dose to external exposure like CT is direction sensitive, and this characteristic feature makes organ based TCM to be an effective way to reduce the eye lens dose, so more clinical use of this technique were recommended. National Nature Science Foundation of China(No.11475047)

  16. Is ophthalmology evidence based? A clinical audit of the emergency unit of a regional eye hospital

    PubMed Central

    Lai, T Y Y; Wong, V W Y; Leung, G M

    2003-01-01

    Aim: To evaluate the proportion of interventions that are evidence based in the acute care unit of a regional eye hospital. Methods: A prospective clinical audit was carried out at Hong Kong Eye Hospital in July 2002 to investigate the extent to which ophthalmic practices were evidence based. The major diagnosis and intervention provided were identified through chart review. A corresponding literature search using Medline and the Cochrane Library was performed to assess the degree to which each intervention was based on current, best evidence. Each diagnosis intervention pair was accordingly analysed and graded. The level of best, current evidence supporting each intervention was graded and analysed. Results: A total of 274 consecutive consultation episodes were examined. 22 cases were excluded since no diagnosis or intervention was made during the consultation. 108 (42.9%) patient interventions were found to be based on evidence from systematic reviews, meta-analyses, or randomised controlled trials (RCT). Evidence from prospective or retrospective observational studies supported the interventions in 86 (34.1%) patients. In 58 (23.0%) cases, no evidence or opposing evidence was found regarding the intervention. The proportion of evidence based on RCT or systematic reviews was higher for surgical interventions compared with non-surgical interventions (p=0.007). The proportion of interventions based on RCT or systematic reviews was higher for specialist ophthalmologists than trainee ophthalmologists (p=0.021). Conclusion: This study demonstrated that the majority of interventions in the ophthalmic unit were evidence based and comparable to the experience of other specialties. PMID:12642295

  17. Symmetric Kullback-Leibler Metric Based Tracking Behaviors for Bioinspired Robotic Eyes

    PubMed Central

    Liu, Hengli; Luo, Jun; Wu, Peng; Xie, Shaorong; Li, Hengyu

    2015-01-01

    A symmetric Kullback-Leibler metric based tracking system, capable of tracking moving targets, is presented for a bionic spherical parallel mechanism to minimize a tracking error function to simulate smooth pursuit of human eyes. More specifically, we propose a real-time moving target tracking algorithm which utilizes spatial histograms taking into account symmetric Kullback-Leibler metric. In the proposed algorithm, the key spatial histograms are extracted and taken into particle filtering framework. Once the target is identified, an image-based control scheme is implemented to drive bionic spherical parallel mechanism such that the identified target is to be tracked at the center of the captured images. Meanwhile, the robot motion information is fed forward to develop an adaptive smooth tracking controller inspired by the Vestibuloocular Reflex mechanism. The proposed tracking system is designed to make the robot track dynamic objects when the robot travels through transmittable terrains, especially bumpy environment. To perform bumpy-resist capability under the condition of violent attitude variation when the robot works in the bumpy environment mentioned, experimental results demonstrate the effectiveness and robustness of our bioinspired tracking system using bionic spherical parallel mechanism inspired by head-eye coordination. PMID:27019592

  18. Symmetric Kullback-Leibler Metric Based Tracking Behaviors for Bioinspired Robotic Eyes.

    PubMed

    Liu, Hengli; Luo, Jun; Wu, Peng; Xie, Shaorong; Li, Hengyu

    2015-01-01

    A symmetric Kullback-Leibler metric based tracking system, capable of tracking moving targets, is presented for a bionic spherical parallel mechanism to minimize a tracking error function to simulate smooth pursuit of human eyes. More specifically, we propose a real-time moving target tracking algorithm which utilizes spatial histograms taking into account symmetric Kullback-Leibler metric. In the proposed algorithm, the key spatial histograms are extracted and taken into particle filtering framework. Once the target is identified, an image-based control scheme is implemented to drive bionic spherical parallel mechanism such that the identified target is to be tracked at the center of the captured images. Meanwhile, the robot motion information is fed forward to develop an adaptive smooth tracking controller inspired by the Vestibuloocular Reflex mechanism. The proposed tracking system is designed to make the robot track dynamic objects when the robot travels through transmittable terrains, especially bumpy environment. To perform bumpy-resist capability under the condition of violent attitude variation when the robot works in the bumpy environment mentioned, experimental results demonstrate the effectiveness and robustness of our bioinspired tracking system using bionic spherical parallel mechanism inspired by head-eye coordination. PMID:27019592

  19. Graphene-Based Bioinspired Compound Eyes for Programmable Focusing and Remote Actuation.

    PubMed

    Wang, Lanlan; Li, Fang; Liu, Hongzhong; Jiang, Weitao; Niu, Dong; Li, Rui; Yin, Lei; Shi, Yongsheng; Chen, Bangdao

    2015-09-30

    Inspired by creatures' eyes, bioinspired compound eyes (BCEs) endowed with larger fields of view and vari-focal capability are extremely appealing in micro-optical devices. However, the present actuation strategies of BCEs commonly demand complicated fields, e.g., electro-wetting actuation, dielectrophoretic drive and pressure gradient, which greatly limits their practical applications. In this work, the photothermal conversion of graphene nanosheets (GNSs) is first utilized to fabricate lenslets toward BCEs. Under the actuation of near-infrared (nIR) pulsed laser, GNSs absorb photo energy and convert it to thermal energy, which increases the temperature of lenslets and then leads to the adjustment of lenslet curvature. At a result, BCEs manifest a reversible 4-fold zoom and a wide FOV up to 160°. In addition, BCEs also perform the programmable focusing by selectively confining nIR laser to a vari-focal region. In contrast with traditional BCEs, graphene-based BCEs are versatile with wide FOV and vari-focal ability by nIR actuation. Herein, these excellent properties make graphene-based BCEs promising for remote-driven microfluidic devices. PMID:26360819

  20. Evidence of an eye movement-based memory effect in congenital prosopagnosia.

    PubMed

    Bate, Sarah; Haslam, Catherine; Tree, Jeremy J; Hodgson, Timothy L

    2008-01-01

    While extensive work has examined the role of covert recognition in acquired prosopagnosia, little attention has been directed to this process in the congenital form of the disorder. Indeed, evidence of covert recognition has only been demonstrated in one congenital case in which autonomic measures provided evidence of recognition (Jones and Tranel, 2001), whereas two investigations using behavioural indicators failed to demonstrate the effect (de Haan and Campbell, 1991; Bentin et al., 1999). In this paper, we use a behavioural indicator, an "eye movement-based memory effect" (Althoff and Cohen, 1999), to provide evidence of covert recognition in congenital prosopagnosia. In an initial experiment, we examined viewing strategies elicited to famous and novel faces in control participants, and found fewer fixations and reduced regional sampling for famous compared to novel faces. In a second experiment, we examined the same processes in a patient with congenital prosopagnosia (AA), and found some evidence of an eye movement-based memory effect regardless of his recognition accuracy. Finally, we examined whether a difference in scanning strategy was evident for those famous faces AA failed to explicitly recognise, and again found evidence of reduced sampling for famous faces. We use these findings to (a) provide evidence of intact structural representations in a case of congenital prosopagnosia, and (b) to suggest that covert recognition can be demonstrated using behavioural indicators in this disorder. PMID:18489961

  1. Web-based Training in German University Eye Hospitals – Education 2.0?

    PubMed Central

    Handzel, Daniel M.; Hesse, L.

    2011-01-01

    Purpose: To analyse web-based training in ophthalmology offered by German university eye hospitals. Methods: In January 2010 the websites of all 36 German university hospitals were searched for information provided for visitors, students and doctors alike. We evaluated the offer in terms of quantity and quality. Results: All websites could be accessed at the time of the study. 28 pages provided information for students and doctors, one page only for students, three exclusively for doctors. Four pages didn’t offer any information for these target groups. The websites offered information on events like congresses or students curricular education, there were also material for download for these events or for other purposes. We found complex e-learning-platforms on 9 pages. These dealt with special ophthalmological topics in a didactic arrangement. In spite of the extensive possibilities offered by the technology of Web 2.0, many conceivable tools were only rarely made available. It was not always possible to determine if the information provided was up-to-date, very often the last actualization of the content was long ago. On one page the date for the last change was stated as 2004. Conclusion: Currently there are 9 functional e-learning-applications offered by German university eye hospitals. Two additional hospitals present links to a project of the German Ophthalmological Society. There was a considerable variation in quantity and quality. No website made use of crediting successful studying, e.g. with CME-points or OSCE-credits. All German university eye hospitals present themselves in the World Wide Web. However, the lack of modern, technical as well as didactical state-of-the-art learning applications is alarming as it leaves an essential medium of today’s communication unused. PMID:21866245

  2. Eye Emergencies

    MedlinePlus

    ... Emergencies Cardiac Emergencies Eye Emergencies Lung Emergencies Surgeries Eye Emergencies Marfan syndrome significantly increases your risk of ... light-sensitive membrane in the back of the eye (the retina) from its supporting layers. It is ...

  3. Eye Wear

    MedlinePlus

    Eye wear protects or corrects your vision. Examples are Sunglasses Safety goggles Glasses (also called eyeglasses) Contact ... jobs and some sports carry a risk of eye injury. Thousands of children and adults get eye ...

  4. Eye Injuries

    MedlinePlus

    The structure of your face helps protect your eyes from injury. Still, injuries can damage your eye, sometimes severely enough that you could lose your vision. Most eye injuries are preventable. If you play sports or ...

  5. Eye Cancer

    MedlinePlus

    Cancer of the eye is uncommon. It can affect the outer parts of the eye, such as the eyelid, which are made up ... adults are melanoma and lymphoma. The most common eye cancer in children is retinoblastoma, which starts in ...

  6. Eye Diseases

    MedlinePlus

    ... the back of the eye Macular degeneration - a disease that destroys sharp, central vision Diabetic eye problems ... defense is to have regular checkups, because eye diseases do not always have symptoms. Early detection and ...

  7. Eye Injuries

    MedlinePlus

    ... of your face helps protect your eyes from injury. Still, injuries can damage your eye, sometimes severely enough that you could lose your vision. Most eye injuries are preventable. If you play sports or work ...

  8. Study on warning radius of diffuse reflection laser warning based on fish-eye lens

    NASA Astrophysics Data System (ADS)

    Chen, Bolin; Zhang, Weian

    2013-09-01

    The diffuse reflection type of omni-directional laser warning based on fish-eye lens is becoming more and more important. As one of the key parameters of warning system, the warning radius should be put into investigation emphatically. The paper firstly theoretically analyzes the energy detected by single pixel of FPA detector in the system under complicated environment. Then the least energy detectable by each single pixel of the system is computed in terms of detector sensitivity, system noise, and minimum SNR. Subsequently, by comparison between the energy detected by single pixel and the least detectable energy, the warning radius is deduced from Torrance-Sparrow five-parameter semiempirical statistic model. Finally, a field experiment was developed to validate the computational results. It has been found that the warning radius has a close relationship with BRDF parameters of the irradiated target, propagation distance, angle of incidence, and detector sensitivity, etc. Furthermore, an important fact is shown that the experimental values of warning radius are always less than that of theoretical ones, due to such factors as the optical aberration of fish-eye lens, the transmissivity of narrowband filter, and the packing ratio of detector.

  9. HotEye (tm) Based Coordinate Measuring Machine for Forging Industry

    SciTech Connect

    OG Technologies

    2003-06-09

    The objective of this project is to develop a 3 dimensional measurement system for the domestic forging industry based on HotEye{trademark}. This technology will allow high definition camera to accurately image a red hot object. The project marries conventional Coordinate Measurement Machine ''CMM'' technology to HotEye{trademark} technology to permit the accurate measurement of forged parts while they are at high temperature. Being able to take such measurements will dramatically reduce the amount of scrap produced by the domestic forging industry. This industry wastes a significant amount of energy because of the high rate of scrap it produces. OGT will: (1) Develop a 3D measurement sensor head that will work on a part at a temperature up to 1,450 C with an accuracy of 0.1mm or better and with a scanning speed of less than 10 seconds for an area of 100mm x 100mm. (2) Develop a Virtual-Fixturing software package to alleviate the need of precise hard fixturing. (3) Integrate the 3D measurement sensor head and the Virtual-Fixturing software into a standard CMM, both hardware (replacing the probes) and software (data format and user interface match) so that the system can automatically perform a complete preprogrammed measurement of a hot product. (4) Test and evaluate the system in a forging facility.

  10. Evaluation of helmet-mounted display targeting symbology based on eye tracking technology

    NASA Astrophysics Data System (ADS)

    Wang, Lijing; Wen, Fuzhen; Ma, Caixin; Zhao, Shengchu; Liu, Xiaodong

    2014-06-01

    The purpose of this paper is to find the Target Locator Lines (TLLs) which perform best by contrasting and comparing experiment based on three kinds of TTLs of fighter HMD. 10 university students, male, with an average age of 21-23, corrected visual acuity 1.5, participated in the experiment. In the experiment, head movement data was obtained by TrackIR. The geometric relationship between the coordinates of the real world and coordinates of the visual display was obtained by calculating the distance from viewpoint to midpoint of both eyes and the head movement data. Virtual helmet system simulation experiment environment was created by drawing TLLs of fighter HMD in the flight simulator visual scene. In the experiment, eye tracker was used to record the time and saccade trajectory. The results were evaluated by the duration of the time and saccade trajectory. The results showed that the symbol"locator line with digital vector length indication" cost most time and had the longest length of the saccade trajectory. It is the most ineffective and most unacceptable way. "Locator line with extending head vector length symbol" cost less time and had less length of the saccade trajectory. It is effective and acceptable;"Locator line with reflected vector length symbol" cost the least time and had the least length of the saccade trajectory. It is the most effective and most acceptable way. "Locator line with reflected vector length symbol" performs best. The results will provide reference value for the research of TTLs in future.

  11. Gender is a major factor explaining discrepancies in eye colour prediction based on HERC2/OCA2 genotype and the IrisPlex model.

    PubMed

    Martinez-Cadenas, Conrado; Peña-Chilet, Maria; Ibarrola-Villava, Maider; Ribas, Gloria

    2013-07-01

    In recent years, several studies have greatly increased our understanding of the genetic basis underlying human eye colour variation. A large percentage of the eye colour diversity present in humans can already be genetically explained, so much so that different DNA-based eye colour prediction models, such as IrisPlex, have been recently developed for forensic purposes. Though these models are already highly accurate, they are by no means perfect, with many genotype-phenotype discrepancies still remaining unresolved. In this work we have genotyped six SNPs associated with eye colour (IrisPlex) in 535 individuals from Spain, a Mediterranean population. Aside from different SNP frequencies in Spain compared to Northern Europe, the results for eye colour prediction are quite similar to other studies. However, we have found an association between gender and eye colour prediction. When comparing similar eye colour genetic profiles, females tend, as a whole, to have darker eyes than males (and, conversely, males lighter than females). These results are also corroborated by the revision and meta-analysis of data from previously published eye colour genetic studies in several Caucasian populations, which significantly support the fact that males are more likely to have blue eyes than females, while females tend to show higher frequencies of green and brown eyes than males. This significant gender difference would suggest that there is an as yet unidentified gender-related factor contributing to human eye colour variation. PMID:23601698

  12. Absolute radiometric calibration of the RapidEye multispectral imager using the reflectance-based vicarious calibration method

    NASA Astrophysics Data System (ADS)

    Naughton, Denis; Brunn, Andreas; Czapla-Myers, Jeff; Douglass, Scott; Thiele, Michael; Weichelt, Horst; Oxfort, Michael

    2011-01-01

    RapidEye AG is a commercial provider of geospatial information products and customized solutions derived from Earth observation image data. The source of the data is the RapidEye constellation consisting of five low-earth-orbit imaging satellites. We describe the rationale, methods, and results of a reflectance-based vicarious calibration campaign that was conducted between April 2009 and May 2010 at Railroad Valley Playa and Ivanpah Playa to determine the on-orbit radiometric accuracy of the RapidEye sensor. In situ surface spectral reflectance measurements of known ground targets and an assessment of the atmospheric conditions above the sites were taken during spacecraft overpasses. The ground data are used as input to a radiative transfer code to compute a band-specific top-of-atmosphere spectral radiance. A comparison of these predicted values based on absolute physical data to the measured at-sensor spectral radiance provide the absolute calibration of the sensor. Initial assessments show that the RapidEye sensor response is within 8% of the predicted values. Outcomes from this campaign are then used to update the calibration parameters in the ground segment processing system. Subsequent verification events confirmed that the measured RapidEye response improved to within 4% of the predictions based on the vicarious calibration method.

  13. A multi level system design for vigilance measurement based on head posture estimation and eyes blinking

    NASA Astrophysics Data System (ADS)

    Teyeb, Ines; Jemai, Olfa; Zaied, Mourad; ben Amar, Chokri

    2015-12-01

    Driving security is an important task for human society. The major challenge in the field of accident avoidance systems is the driver vigilance monitoring. The lack of vigilance can be noticed by various ways, such as, fatigue, drowsiness and distraction. Hence, the need of a reliable driver's vigilance decrease detection system which can alert drivers before a mishap happens. In this paper, we present a novel approach for vigilance estimation based on multilevel system by combining head movement analysis and eyes blinking. We have used Viola and Jones algorithm to analyse head movement and a classification system using wavelet networks for eyelid closure measuring. The contribution of our application is classifiying the vigilance state at multi level. This is different from the binary-class (awakening or hypovigilant state) existing in most popular systems.

  14. High-speed, image-based eye tracking with a scanning laser ophthalmoscope

    PubMed Central

    Sheehy, Christy K.; Yang, Qiang; Arathorn, David W.; Tiruveedhula, Pavan; de Boer, Johannes F.; Roorda, Austin

    2012-01-01

    We demonstrate a high-speed, image-based tracking scanning laser ophthalmoscope (TSLO) that can provide high fidelity structural images, real-time eye tracking and targeted stimulus delivery. The system was designed for diffraction-limited performance over an 8° field of view (FOV) and operates with a flexible field of view of 1°–5.5°. Stabilized videos of the retina were generated showing an amplitude of motion after stabilization of 0.2 arcmin or less across all frequencies. In addition, the imaging laser can be modulated to place a stimulus on a targeted retinal location. We show a stimulus placement accuracy with a standard deviation less than 1 arcmin. With a smaller field size of 2°, individual cone photoreceptors were clearly visible at eccentricities outside of the fovea. PMID:23082300

  15. Similarity-Based Interference During Language Comprehension: Evidence from Eye Tracking During Reading

    PubMed Central

    Gordon, Peter C.; Hendrick, Randall; Johnson, Marcus; Lee, Yoonhyoung

    2006-01-01

    The nature of working memory operation during complex sentence comprehension was studied using eye-tracking methodology. Readers had difficulty when the syntax of a sentence required them to hold two similar noun phrases (NPs) in working memory before syntactically and semantically integrating either of the NPs with a verb. In sentence structures that placed these NPs at the same linear distances from one another but allowed integration with a verb for one of the NPs, the comprehension difficulty was not seen. These results are interpreted as indicating that similarity-based interference occurs online during the comprehension of complex sentences and that the degree of memory accessibility conventionally associated with different types of NPs does not have a strong effect on sentence processing. PMID:17087585

  16. A novel lobster-eye imaging system based on Schmidt-type objective for X-ray-backscattering inspection

    NASA Astrophysics Data System (ADS)

    Xu, Jie; Wang, Xin; Zhan, Qi; Huang, Shengling; Chen, Yifan; Mu, Baozhong

    2016-07-01

    This paper presents a novel lobster-eye imaging system for X-ray-backscattering inspection. The system was designed by modifying the Schmidt geometry into a treble-lens structure in order to reduce the resolution difference between the vertical and horizontal directions, as indicated by ray-tracing simulations. The lobster-eye X-ray imaging system is capable of operating over a wide range of photon energies up to 100 keV. In addition, the optics of the lobster-eye X-ray imaging system was tested to verify that they meet the requirements. X-ray-backscattering imaging experiments were performed in which T-shaped polymethyl-methacrylate objects were imaged by the lobster-eye X-ray imaging system based on both the double-lens and treble-lens Schmidt objectives. The results show similar resolution of the treble-lens Schmidt objective in both the vertical and horizontal directions. Moreover, imaging experiments were performed using a second treble-lens Schmidt objective with higher resolution. The results show that for a field of view of over 200 mm and with a 500 mm object distance, this lobster-eye X-ray imaging system based on a treble-lens Schmidt objective offers a spatial resolution of approximately 3 mm.

  17. A novel lobster-eye imaging system based on Schmidt-type objective for X-ray-backscattering inspection.

    PubMed

    Xu, Jie; Wang, Xin; Zhan, Qi; Huang, Shengling; Chen, Yifan; Mu, Baozhong

    2016-07-01

    This paper presents a novel lobster-eye imaging system for X-ray-backscattering inspection. The system was designed by modifying the Schmidt geometry into a treble-lens structure in order to reduce the resolution difference between the vertical and horizontal directions, as indicated by ray-tracing simulations. The lobster-eye X-ray imaging system is capable of operating over a wide range of photon energies up to 100 keV. In addition, the optics of the lobster-eye X-ray imaging system was tested to verify that they meet the requirements. X-ray-backscattering imaging experiments were performed in which T-shaped polymethyl-methacrylate objects were imaged by the lobster-eye X-ray imaging system based on both the double-lens and treble-lens Schmidt objectives. The results show similar resolution of the treble-lens Schmidt objective in both the vertical and horizontal directions. Moreover, imaging experiments were performed using a second treble-lens Schmidt objective with higher resolution. The results show that for a field of view of over 200 mm and with a 500 mm object distance, this lobster-eye X-ray imaging system based on a treble-lens Schmidt objective offers a spatial resolution of approximately 3 mm. PMID:27475544

  18. Etiology and Features of Eyes with Rubeosis Iridis among Korean Patients: A Population-Based Single Center Study

    PubMed Central

    Jeong, Yun Cheol; Hwang, Young Hoon

    2016-01-01

    Purpose To estimate the etiology and features of the eyes with rubeosis iridis among Korean patients. Materials and Methods This study is a retrospective review of 533 Korean patients with rubeosis iridis who visited an eye hospital in Seoul, Korea. We defined rubeosis iridis as visible blood vessels on the iris surface detected during a slit-lamp examination. All cases were reviewed for age at the time of diagnosis, medical history, the most likely cause of rubeosis iridis, visual acuity, and intraocular pressure. Results The most commonly observed cause of rubeosis iridis was diabetic retinopathy (DR; n = 337, 63.2%), followed by retinal vein occlusion (RVO; n = 101, 18.9%), ocular ischemic syndrome (OIS; n = 24, 4.5%), retinal detachment (n = 17, 3.2%), and uveitis (n = 15, 2.8%). The cause was classified as miscellaneous in 18 cases (3.4%); in 21 eyes (3.9%), the cause was not clear. Age at the time of rubeosis iridis diagnosis was lower in patients with DR (56.5 years) than in those with RVO (61.0 years) and OIS (64.8 years; P < 0.01). Intraocular pressure of the eyes with DR (37.3 mmHg) and RVO (39.5 mmHg) was higher than that of the eyes with OIS (25.8 mmHg; P < 0.01). Conclusion In our population-based single center study, DR was the leading cause of rubeosis iridis followed by RVO and OIS among Korean patients. The clinical characteristics of the eyes with rubeosis iridis differed according to etiology. This finding may be useful when assessing eyes with rubeosis iridis. PMID:27490797

  19. Structure Modulates Similarity-Based Interference in Sluicing: An Eye Tracking study

    PubMed Central

    Harris, Jesse A.

    2015-01-01

    In cue-based content-addressable approaches to memory, a target and its competitors are retrieved in parallel from memory via a fast, associative cue-matching procedure under a severely limited focus of attention. Such a parallel matching procedure could in principle ignore the serial order or hierarchical structure characteristic of linguistic relations. I present an eye tracking while reading experiment that investigates whether the sentential position of a potential antecedent modulates the strength of similarity-based interference, a well-studied effect in which increased similarity in features between a target and its competitors results in slower and less accurate retrieval overall. The manipulation trades on an independently established Locality bias in sluiced structures to associate a wh-remnant (which ones) in clausal ellipsis with the most local correlate (some wines), as in The tourists enjoyed some wines, but I don't know which ones. The findings generally support cue-based parsing models of sentence processing that are subject to similarity-based interference in retrieval, and provide additional support to the growing body of evidence that retrieval is sensitive to both the structural position of a target antecedent and its competitors, and the specificity or diagnosticity of retrieval cues. PMID:26733893

  20. Eye gaze performance for children with severe physical impairments using gaze-based assistive technology—A longitudinal study

    PubMed Central

    Borgestig, Maria; Sandqvist, Jan; Parsons, Richard; Falkmer, Torbjörn; Hemmingsson, Helena

    2016-01-01

    ABSTRACT Gaze-based assistive technology (gaze-based AT) has the potential to provide children affected by severe physical impairments with opportunities for communication and activities. This study aimed to examine changes in eye gaze performance over time (time on task and accuracy) in children with severe physical impairments, without speaking ability, using gaze-based AT. A longitudinal study with a before and after design was conducted on 10 children (aged 1–15 years) with severe physical impairments, who were beginners to gaze-based AT at baseline. Thereafter, all children used the gaze-based AT in daily activities over the course of the study. Compass computer software was used to measure time on task and accuracy with eye selection of targets on screen, and tests were performed with the children at baseline, after 5 months, 9–11 months, and after 15–20 months. Findings showed that the children improved in time on task after 5 months and became more accurate in selecting targets after 15–20 months. This study indicates that these children with severe physical impairments, who were unable to speak, could improve in eye gaze performance. However, the children needed time to practice on a long-term basis to acquire skills needed to develop fast and accurate eye gaze performance. PMID:26496529

  1. Eye gaze performance for children with severe physical impairments using gaze-based assistive technology-A longitudinal study.

    PubMed

    Borgestig, Maria; Sandqvist, Jan; Parsons, Richard; Falkmer, Torbjörn; Hemmingsson, Helena

    2016-01-01

    Gaze-based assistive technology (gaze-based AT) has the potential to provide children affected by severe physical impairments with opportunities for communication and activities. This study aimed to examine changes in eye gaze performance over time (time on task and accuracy) in children with severe physical impairments, without speaking ability, using gaze-based AT. A longitudinal study with a before and after design was conducted on 10 children (aged 1-15 years) with severe physical impairments, who were beginners to gaze-based AT at baseline. Thereafter, all children used the gaze-based AT in daily activities over the course of the study. Compass computer software was used to measure time on task and accuracy with eye selection of targets on screen, and tests were performed with the children at baseline, after 5 months, 9-11 months, and after 15-20 months. Findings showed that the children improved in time on task after 5 months and became more accurate in selecting targets after 15-20 months. This study indicates that these children with severe physical impairments, who were unable to speak, could improve in eye gaze performance. However, the children needed time to practice on a long-term basis to acquire skills needed to develop fast and accurate eye gaze performance. PMID:26496529

  2. An Examination of Cognitive Processing of Multimedia Information Based on Viewers' Eye Movements

    ERIC Educational Resources Information Center

    Liu, Han-Chin; Chuang, Hsueh-Hua

    2011-01-01

    This study utilized qualitative and quantitative designs and eye-tracking technology to understand how viewers process multimedia information. Eye movement data were collected from eight college students (non-science majors) while they were viewing web pages containing different types of text and illustrations depicting the mechanism of…

  3. A Microcomputer-Based Software Package for Eye-Monitoring Research. Technical Report No. 434.

    ERIC Educational Resources Information Center

    McConkie, George W.; And Others

    A software package is described that collects and reduces eye behavior data (eye position and pupil size) using an IBM-PC compatible computer. Written in C language for speed and portability, it includes several features: (1) data can be simultaneously collected from other sources (such as electroencephalography and electromyography); (2)…

  4. A new rhodamine-based colorimetric chemosensor for naked-eye detection of Cu2 + in aqueous solution

    NASA Astrophysics Data System (ADS)

    Hu, Yang; Zhang, Jing; Lv, Yuan-Zheng; Huang, Xiao-Huan; Hu, Sheng-li

    2016-03-01

    A new colorimetric probe 1 based on rhodamine B lactam was developed for naked-eye detection of Cu2 +. The optical feature of 1 for Cu2 + was investigated by UV-vis absorption spectroscopy. Upon the addition of Cu2 +, the 1 displayed a distinct color change from colorless to pink, which can be directly detected by the naked eye. The stoichiometry of 1 to Cu2 + complex was found to be 1:1 and the naked-eye detection limit was determined as low as 2 μM. The results suggest that the probe 1 may provide a convenient method for visual detection of Cu2 + with high sensitivity.

  5. Is Making a Risky Choice Based on a Weighting and Adding Process? An Eye-Tracking Investigation

    ERIC Educational Resources Information Center

    Su, Yin; Rao, Li-Lin; Sun, Hong-Yue; Du, Xue-Lei; Li, Xingshan; Li, Shu

    2013-01-01

    The debate about whether making a risky choice is based on a weighting and adding process has a long history and is still unresolved. To address this long-standing controversy, we developed a comparative paradigm. Participants' eye movements in 2 risky choice tasks that required participants to choose between risky options in single-play and…

  6. Wide field OCT based microangiography in living human eye (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Zhang, Qinqin; Chen, Chieh-Li; Chu, Zhongdi; Zhang, Anqi; An, Lin; Durbin, Mary; Sharma, Utkarsh; Rosenfeld, Philip J.; Wang, Ruikang K.

    2016-03-01

    To investigate the application of optical microangiography (OMAG) in living human eye. Patients with different macular diseases were recruited, including diabetic retinopathy (DR), geographic atrophy (GA), retinitis pigmentosa (RP), and venous occlusion, et al. Wide field OCT angiography images can be generated by montage scanning protocol based on the tracking system. OMAG algorithm based on complex differentiation was used to extract the blood flow and removed the bulk motion by 2D cross-correlation method. The 3D angiography was segmented into 3 layers in the retina and 2 layers in the choroid. The en-face maximum projection was used to obtain 2-dimensional angiograms of different layers coded with different colors. Flow and structure images were combined for cross-sectional view. En face OMAG images of different macular diseases showed a great agreement with FA. Meanwhile, OMAG gave more distinct vascular network visions that were less affected by hemorrhage and leakage. The MAs were observed in both superficial and middle retinal layers based on OMAG angiograms in different layers of DR patients. The contour line of FAZ was extracted as well, which can be quantitative the retinal diseases. For GA patient, the damage of RPE layer enhanced the penetration of light and enabled the acquisition of choriocapillaries and choroidal vessels. The wide field OMAG angiogram enabled the capability of capturing the entire geographic atrophy. OMAG provides depth-resolved information and detailed vascular images of DR and GA patients, providing a better visualization of vascular network compared to FA.

  7. Posterior segment eye disease in sub-Saharan Africa: review of recent population-based studies

    PubMed Central

    Bastawrous, Andrew; Burgess, Philip I; Mahdi, Abdull M; Kyari, Fatima; Burton, Matthew J; Kuper, Hannah

    2014-01-01

    Objective To assess the burden of posterior segment eye diseases (PSEDs) in sub-Saharan Africa (SSA). Methods We reviewed published population-based data from SSA and other relevant populations on the leading PSED, specifically glaucoma, diabetic retinopathy and age-related macular degeneration, as causes of blindness and visual impairment in adults. Data were extracted from population-based studies conducted in SSA and elsewhere where relevant. Results PSEDs, when grouped or as individual diseases, are a major contributor to blindness and visual impairment in SSA. PSED, grouped together, was usually the second leading cause of blindness after cataract, ranging as a proportion of blindness from 13 to 37%. Conclusions PSEDs are likely to grow in importance as causes of visual impairment and blindness in SSA in the coming years as populations grow, age and become more urban in lifestyle. African-based cohort studies are required to help estimate present and future needs and plan services to prevent avoidable blindness. PMID:24479434

  8. Optic Disc Perfusion in Primary Open Angle and Normal Tension Glaucoma Eyes Using Optical Coherence Tomography-Based Microangiography

    PubMed Central

    Wen, Joanne C.; Zhang, Qinqin; Xin, Chen; Gupta, Divakar; Mudumbai, Raghu C.; Johnstone, Murray A.; Wang, Ruikang K.; Chen, Philip P.

    2016-01-01

    Purpose To investigate optic disc perfusion differences in normal, primary open-angle glaucoma (POAG), and normal tension glaucoma (NTG) eyes using optical microangiography (OMAG) based optical coherence tomography (OCT) angiography technique. Design Cross-sectional, observational study. Subjects Twenty-eight normal, 30 POAG, and 31 NTG subjects. Methods One eye from each subject was scanned with a 68 kHz Cirrus HD-OCT 5,000-based OMAG prototype system centered at the optic nerve head (ONH) (Carl Zeiss Meditec Inc, Dublin, CA). Microvascular images were generated from the OMAG dataset by detecting the differences in OCT signal between consecutive B-scans. The pre-laminar layer (preLC) was isolated by a semi-automatic segmentation program. Main Outcome Measures Optic disc perfusion, quantified as flux, vessel area density, and normalized flux (flux normalized by the vessel area) within the ONH. Results Glaucomatous eyes had significantly lower optic disc perfusion in preLC in all three perfusion metrics (p<0.0001) compared to normal eyes. The visual field (VF) mean deviation (MD) and pattern standard deviation (PSD) were similar between the POAG and NTG groups, and no differences in optic disc perfusion were observed between POAG and NTG. Univariate analysis revealed significant correlation between optic disc perfusion and VF MD, VF PSD, and rim area in both POAG and NTG groups (p≤0.0288). However, normalized optic disc perfusion was correlated with some structural measures (retinal nerve fiber layer thickness and ONH cup/disc ratio) only in POAG eyes. Conclusions Optic disc perfusion detected with OMAG was significantly reduced in POAG and NTG groups compared to normal controls, but no difference was seen between POAG and NTG groups with similar levels of VF damage. Disc perfusion was significantly correlated with VF MD, VF PSD, and rim area in glaucomatous eyes. Vascular changes at the optic disc as measured using OMAG may provide useful information for

  9. Eye detection based on head contour geometry and wavelet subband projection

    NASA Astrophysics Data System (ADS)

    Wang, Jing-Weing; Chen, Wen-Yuan

    2006-05-01

    We propose a novel two-step approach for eyes detection in complex scenes including both indoor and outdoor environments. This approach adopts face localization to eye extraction strategy. First, we use energy analysis to remove most noise-like regions to enhance face localization performance, and then use the head contour detection (HCD) approach to search for the best combinations of facial sides and head contours with an anthropometric measure, and thereafter the face-of-interest (FOI) region is located. In the meantime, via the deedging preprocessing for facial sides, a wavelet subband interorientation projection method is adopted to select eye-like candidates. Along with the geometric discrimination among the facial components, such as the eyes, nose, and mouth, this eye verification rule verifies the selected eyes candidates. The eye positions are then marked and refined by the bounding box of FOI region as the ellipse being the best fit of the facial oval shape. The experimental results demonstrate that the performance of our proposed method has significant improvement compared to others on three head-and-shoulder databases.

  10. Monitoring eye movement with a computer based Electro-oculogram (EOG).

    PubMed

    Dibble, Jamie M; Teters, Cherish K

    2004-01-01

    This project investigated ways to improve retinal laser surgery techniques. Currently, the surgery is manual and not very accurate because the eye has a tendency to move involuntarily and the laser can cause permanent damage to the patient if the eye moves out of range. Therefore, an Electro-oculogram (EOG) system was designed and tested capable of recording eye movement in both horizontal and vertical directions using the voltages produced by the eye for the purpose of feedback to the surgeon. The EOG system consisted of various filters and amplifiers to amplify the small signals created by the eye, which were obtained using surface electrodes placed around the eyes. An LED board was also designed for the subject to follow various LED lights with his/her eyes in all directions. A program was written with LabView software that was used to control the LED board as well as record and analyze the EOG signals. MatLab was used in correlation with LabView to perform additional filtering and to find the mean, root square mean, and standard deviation of the signal. This data was used to determine if a relationship exists between the direction of eye movement and the voltage produced by the eye. The EOG system and LED board operated as expected and the LabView program was capable of recording and analyzing the signals. The information gathered from this project could make retinal laser surgery more precise and safer by alleviating the potential for error and therefore unintentional damage to the patient. PMID:15134002

  11. Fast cat-eye effect target recognition based on saliency extraction

    NASA Astrophysics Data System (ADS)

    Li, Li; Ren, Jianlin; Wang, Xingbin

    2015-09-01

    Background complexity is a main reason that results in false detection in cat-eye target recognition. Human vision has selective attention property which can help search the salient target from complex unknown scenes quickly and precisely. In the paper, we propose a novel cat-eye effect target recognition method named Multi-channel Saliency Processing before Fusion (MSPF). This method combines traditional cat-eye target recognition with the selective characters of visual attention. Furthermore, parallel processing enables it to achieve fast recognition. Experimental results show that the proposed method performs better in accuracy, robustness and speed compared to other methods.

  12. A neural model of the frontal eye fields with reward-based learning.

    PubMed

    Ye, Weijie; Liu, Shenquan; Liu, Xuanliang; Yu, Yuguo

    2016-09-01

    Decision-making is a flexible process dependent on the accumulation of various kinds of information; however, the corresponding neural mechanisms are far from clear. We extended a layered model of the frontal eye field to a learning-based model, using computational simulations to explain the cognitive process of choice tasks. The core of this extended model has three aspects: direction-preferred populations that cluster together the neurons with the same orientation preference, rule modules that control different rule-dependent activities, and reward-based synaptic plasticity that modulates connections to flexibly change the decision according to task demands. After repeated attempts in a number of trials, the network successfully simulated three decision choice tasks: an anti-saccade task, a no-go task, and an associative task. We found that synaptic plasticity could modulate the competition of choices by suppressing erroneous choices while enhancing the correct (rewarding) choice. In addition, the trained model captured some properties exhibited in animal and human experiments, such as the latency of the reaction time distribution of anti-saccades, the stop signal mechanism for canceling a reflexive saccade, and the variation of latency to half-max selectivity. Furthermore, the trained model was capable of reproducing the re-learning procedures when switching tasks and reversing the cue-saccade association. PMID:27284696

  13. The Effectiveness of Panoramic Maps Design: a Preliminary Study Based on Mobile Eye-Tracking

    NASA Astrophysics Data System (ADS)

    Balzarini, R.; Murat, M.

    2016-06-01

    This paper presents preliminary results from an ongoing research based on the study of visual attention through mobile eye-tracking techniques. The visual-cognitive approach investigates the reading-comprehension of a particular territorial representation: ski trails maps. The general issue of the study is to provide insights about the effectiveness of panoramic ski maps and more broadly, to suggest innovative efficient representation of the geographic information in mountain. According to some mountain operators, the information provided by paper ski maps no longer meets the needs of a large part of the customers; the question now arises of their adaptation to new digital practices (iPhone, tablets). In a computerized process perspective, this study particularly focuses on the representations, and the inferred information, which are really helpful to the users-skiers to apprehend the territory and make decisions, and which could be effectively replicated into a digital system. The most interesting output relies on the relevance of the panorama view: panorama still fascinates, but contrary to conventional wisdom, the information it provides does not seem to be useful to the skier. From a socio-historical perspective this study shows how empirical evidence-based approach can support the change: our results enhance the discussion on the effectiveness of the message that mountain operators want to convey to the tourist and therefore, on the renewal of (geographical) information in ski resorts.

  14. Updating OSHA Standards Based on National Consensus Standards; Eye and Face Protection. Final rule.

    PubMed

    2016-03-25

    On March 13, 2015, OSHA published in the Federal Register a notice of proposed rulemaking (NPRM) to revise its eye and face protection standards for general industry, shipyard employment, marine terminals, longshoring, and construction by updating the references to national consensus standards approved by the American National Standards Institute (ANSI). OSHA received no significant objections from commenters and therefore is adopting the amendments as proposed. This final rule updates the references in OSHA's eye and face standards to reflect the most recent edition of the ANSI/International Safety Equipment Association (ISEA) eye and face protection standard. It removes the oldest-referenced edition of the same ANSI standard. It also amends other provisions of the construction eye and face protection standard to bring them into alignment with OSHA's general industry and maritime standards. PMID:27017630

  15. Healthy Eyes

    MedlinePlus

    ... please turn Javascript on. Healthy Eyes Maintaining Your Vision Click for more information Taking good care of ... are qualified to perform eye exams. Aging and Vision Changes As you age, it is normal to ...

  16. Eye Cancer

    MedlinePlus

    ... adults are melanoma and lymphoma. The most common eye cancer in children is retinoblastoma, which starts in the cells of the retina. ... from other parts of the body. Treatment for eye cancer varies by the type and by how advanced ...

  17. Eye Anatomy

    MedlinePlus

    ... News About Us Donate In This Section Eye Anatomy en Español email Send this article to a ... You at Risk For Glaucoma? Childhood Glaucoma Eye Anatomy Five Common Glaucoma Tests Glaucoma Facts and Stats ...

  18. Your Eyes

    MedlinePlus

    ... the eye and keeps it healthy. previous continue Light, Lens, Action These next parts are really cool, ... the eye. previous continue Rods and Cones Process Light The retina uses special cells called rods and ...

  19. Role of muscle pulleys in producing eye position-dependence in the angular vestibuloocular reflex: a model-based study

    NASA Technical Reports Server (NTRS)

    Thurtell, M. J.; Kunin, M.; Raphan, T.; Wall, C. C. (Principal Investigator)

    2000-01-01

    It is well established that the head and eye velocity axes do not always align during compensatory vestibular slow phases. It has been shown that the eye velocity axis systematically tilts away from the head velocity axis in a manner that is dependent on eye-in-head position. The mechanisms responsible for producing these axis tilts are unclear. In this model-based study, we aimed to determine whether muscle pulleys could be involved in bringing about these phenomena. The model presented incorporates semicircular canals, central vestibular pathways, and an ocular motor plant with pulleys. The pulleys were modeled so that they brought about a rotation of the torque axes of the extraocular muscles that was a fraction of the angle of eye deviation from primary position. The degree to which the pulleys rotated the torque axes was altered by means of a pulley coefficient. Model input was head velocity and initial eye position data from passive and active yaw head impulses with fixation at 0 degrees, 20 degrees up and 20 degrees down, obtained from a previous experiment. The optimal pulley coefficient required to fit the data was determined by calculating the mean square error between data and model predictions of torsional eye velocity. For active head impulses, the optimal pulley coefficient varied considerably between subjects. The median optimal pulley coefficient was found to be 0.5, the pulley coefficient required for producing saccades that perfectly obey Listing's law when using a two-dimensional saccadic pulse signal. The model predicted the direction of the axis tilts observed in response to passive head impulses from 50 ms after onset. During passive head impulses, the median optimal pulley coefficient was found to be 0.21, when roll gain was fixed at 0.7. The model did not accurately predict the alignment of the eye and head velocity axes that was observed early in the response to passive head impulses. We found that this alignment could be well predicted if

  20. Great apes generate goal-based action predictions: an eye-tracking study.

    PubMed

    Kano, Fumihiro; Call, Josep

    2014-09-01

    To examine great apes' on-line prediction of other individuals' actions, we used an eye-tracking technique and an experimental paradigm previously used to test human infants. Twenty-two great apes, including bonobos, chimpanzees, and orangutans, were familiarized to movie clips of a human hand reaching to grasp one of two objects. Then the objects' locations were swapped, and in the test event, the hand made an incomplete reach between the objects. In a control condition, a mechanical claw performed the same actions. The apes predictively looked at the familiarized goal object rather than the familiarized location when viewing the hand action in the test event. However, they made no prediction when viewing the claw action. These results are similar to those reported previously for human infants, and predictive looking did not differ among the three species of great apes. Thus, great apes make on-line goal-based predictions about the actions of other individuals; this skill is not unique to humans but is shared more widely among primates. PMID:25022278

  1. Eye Problems

    MedlinePlus

    ... Do you have diabetes, and have you noticed any changes in your vision? Yes Over time, too much glucose (sugar) in the ... eye pink, red or irritated, and are there any secretions or mucus from the eye? Yes CONJUNCTIVITIS, also called "PINK EYE," can be caused ...

  2. Eye floaters

    MedlinePlus

    ... eyes are not on the surface of your eyes, but inside them. These floaters are bits of cell debris that drift around ... is the layer in the back of the eye.) If you notice a sudden increase in floaters or if you see floaters along with flashes ...

  3. What the human eye tells the brain: a new approach toward a hardware-based modeling of mental functions

    NASA Astrophysics Data System (ADS)

    Lauinger, N.

    2007-09-01

    A better understanding of intelligent information processing in human vision can be reached through a closer look at the macro- and micro-hardware available in the hierarchy of cortical processors along the main visual pathway connecting the retina, the CGL (corpus geniculatum laterale) and area V1 (cortical visual area 17). The building of the eye is driven by the brain and the engineering of the main visual pathway back to V1 seems to be driven by the eyes. The human eye offers to the brain much more intelligent information about the outer visible world than a camera producing flat 2D images on a CCD. Intelligent processing of visual information in human vision - a strong cooperation between eyes and brain - relays on axes related symmetry operations relevant for navigation in 4D spectral space-times, on a hierarchy of dynamically balanced equilibrium states, on diffractive-optical transformation of the Visible into RGB space, on range mapping based on RGB data (monocular and binocular 3D vision), on illuminant-adaptive optical correlations of local onto global RGB data (color constancy performances) and on invariant fourier-optical log-polar processing of image data (generic object classification; identification of objects). These performances are more compatible with optical processing of modern diffractive-optical sensors and interference-optical correlators than with cameras. The R+D project NAMIROS (Nano- and Micro-3D gratings for Optical Sensors) [8], coordinated by an interdisciplinary team of specialists at Corrsys 3D Sensors AG, describes the roadmap towards a technical realization of outstanding high-tech performances corresponding to human eye-brain co-processing.

  4. Modeling of micro cat's eye retroreflectors using a matrix-based three-dimensional ray tracing technique.

    PubMed

    Yang, Bing-jun; Chao, Keng-hsing; Tsai, Jui-che

    2012-09-01

    In this paper we develop a three-dimensional (3D) ray tracing tool based on the ABCD ray transfer matrices. With symmetric optical components and under paraxial approximation, two sets of 2×2 ABCD matrices, each for a two-dimensional subspace, can be used to describe the 3D ray propagation completely. Compared to commercial ray-tracing software packages, our tool requires no tedious drawing, and the results for various conditions, such as different device dimensions and incident angles, can be easily obtained by simply changing the parameter values used for the calculation. We have employed this matrix-based 3D ray tracing tool to model cat's eye retroreflectors. The cat's eye performance, including the retroreflection efficiency, acceptance angle (i.e., field of view), and beam divergence and deviation, is fully studied. The application of this 3D ray tracing technique can be further extended to other optical components. PMID:22945148

  5. A Model-Based Approach for the Measurement of Eye Movements Using Image Processing

    NASA Technical Reports Server (NTRS)

    Sung, Kwangjae; Reschke, Millard F.

    1997-01-01

    This paper describes a video eye-tracking algorithm which searches for the best fit of the pupil modeled as a circular disk. The algorithm is robust to common image artifacts such as the droopy eyelids and light reflections while maintaining the measurement resolution available by the centroid algorithm. The presented algorithm is used to derive the pupil size and center coordinates, and can be combined with iris-tracking techniques to measure ocular torsion. A comparison search method of pupil candidates using pixel coordinate reference lookup tables optimizes the processing requirements for a least square fit of the circular disk model. This paper includes quantitative analyses and simulation results for the resolution and the robustness of the algorithm. The algorithm presented in this paper provides a platform for a noninvasive, multidimensional eye measurement system which can be used for clinical and research applications requiring the precise recording of eye movements in three-dimensional space.

  6. Solution-based nanosensors for in-field detection with the naked eye.

    PubMed

    Paterson, S; de la Rica, R

    2015-05-21

    Nanomaterials are revolutionising analytical applications with low-cost tests that enable detecting a target molecule in a few steps and with the naked eye. With this approach, non-experts can perform analyses on-site and without utilising electronic readers. This is advantageous in point-of-care diagnostics, in-field measurements and analyses performed in resource-constrained settings. Here we review the main strategies adopted for detecting analytes with the naked eye and at the point of need using plasmonic nanosensors, catalytic nanoparticles and fluorescent nanomaterials. Examples of the detection of ions, glucose, small molecules, peptides and proteins with the nanosensors are explained in detail. PMID:25802896

  7. Towards Quantum Experiments with Human Eye Detectors Based on Cloning via Stimulated Emission ?

    NASA Astrophysics Data System (ADS)

    De Martini, Francesco

    2010-05-01

    In a recent theoretical paper published in Physical Review Letters, Sekatsky, Brunner, Branciard, Gisin, Simon report an extended investigation on some properties of the human eye that affect its behavior as a quantum detector. We believe that the content of this work, albeit appealing at fist sight, is highly questionable simply because the human eye cannot be adopted as a sensing device within any quantum measurement apparatus. Furthermore, the criticism raised by these Authors against a real experiment on Micro—Macro entanglement recently published in Physical Review Letters (100, 253601, 2008) is found misleading and misses its target.

  8. A wavelet based method for automatic detection of slow eye movements: a pilot study.

    PubMed

    Magosso, Elisa; Provini, Federica; Montagna, Pasquale; Ursino, Mauro

    2006-11-01

    Electro-oculographic (EOG) activity during the wake-sleep transition is characterized by the appearance of slow eye movements (SEM). The present work describes an algorithm for the automatic localisation of SEM events from EOG recordings. The algorithm is based on a wavelet multiresolution analysis of the difference between right and left EOG tracings, and includes three main steps: (i) wavelet decomposition down to 10 detail levels (i.e., 10 scales), using Daubechies order 4 wavelet; (ii) computation of energy in 0.5s time steps at any level of decomposition; (iii) construction of a non-linear discriminant function expressing the relative energy of high-scale details to both high- and low-scale details. The main assumption is that the value of the discriminant function increases above a given threshold during SEM episodes due to energy redistribution toward higher scales. Ten EOG recordings from ten male patients with obstructive sleep apnea syndrome were used. All tracings included a period from pre-sleep wakefulness to stage 2 sleep. Two experts inspected the tracings separately to score SEMs. A reference set of SEM (gold standard) were obtained by joint examination by both experts. Parameters of the discriminant function were assigned on three tracings (design set) to minimize the disagreement between the system classification and classification by the two experts; the algorithm was then tested on the remaining seven tracings (test set). Results show that the agreement between the algorithm and the gold standard was 80.44+/-4.09%, the sensitivity of the algorithm was 67.2+/-7.37% and the selectivity 83.93+/-8.65%. However, most errors were not caused by an inability of the system to detect intervals with SEM activity against NON-SEM intervals, but were due to a different localisation of the beginning and end of some SEM episodes. The proposed method may be a valuable tool for computerized EOG analysis. PMID:16497535

  9. Behavioural and eye-movement outcomes in response to text-based reading treatment for acquired alexia.

    PubMed

    Kim, Esther S; Lemke, Shannon F

    2016-01-01

    Text-based reading treatments, such as Multiple Oral Rereading (MOR) and Oral Reading for Language in Aphasia (ORLA) have been used successfully to remediate reading impairments in individuals with acquired alexia, but the mechanisms underlying such improvements are not well understood. In this study, an individual with acquired alexia who demonstrated reliance on a sub-lexical reading strategy (i.e., presence of spelling regularity effect and phonologically plausible errors) underwent 12 weeks of text-based reading treatment combining MOR and ORLA procedures. Behavioural assessments of single-word and text reading, along with eye-tracking assessments were conducted pre-treatment, post-treatment and at 5 month follow-up. Improved reading fluency (rate, accuracy) was observed for both trained and untrained passages. Evidence from behavioural and eye-tracking assessment suggested text-based reading treatment facilitated use of a lexical-semantic reading strategy. Increased frequency and lexicality effects, as well as a shift in initial landing position towards the centre of the word (the "optimal viewing position") were observed at post-treatment and follow-up assessments. These results demonstrate the potential utility of using eye movements as a parameter of interest in addition to traditional behavioural outcomes when investigating response to reading treatment. PMID:25582781

  10. High-sensitive and high-efficient biochemical analysis method using a bionic electronic eye in combination with a smartphone-based colorimetric reader system.

    PubMed

    Kaiqi Su; Quchao Zou; Ning Hu; Ping Wang

    2015-08-01

    Bionic electronic eye (Bionic e-Eye), a developed smartphone-based colorimetric reader system, consists of smartphone or pad (iPhone 4s or iPad 3) as detection instrument and portable accessory as illumination provider, integrating with a wide-angle lens, a piece of lowest-power electro luminescent and a custom-made dark hood. A 96-well microtiter plate (MTP) was positioned on the electro luminescent and Bionic e-Eye captures the detection images by the back camera of smartphone. Being similar to human visual system, the hue, saturation and value (HSV, also called hex cone model) color model was employed in image processing algorithm of Bionic e-Eye. Optimized system dimension was determined by the system steadiness experiment of different photograph distances. Moreover, the commercially available BCA protein assay and CCK8 cell number assay were carried out to evaluate this Bionic e-Eye. Analytical performance of Bionic e-Eye had the better precision, higher sensitivity than microtiter plate reader (MTPR) and previous smartphone-based colorimetric reader for both two assays. Also, Bionic e-Eye using optical image detection had simultaneous and synchronous working mode, while MPTR using machine moving detection had asynchronous working mode in high throughput detection. Therefore, Bionic e-Eye will be an ideal point-of-care (POC) colorimetric detection device in the field of clinical application, industrial quality control, environment monitoring, and food assessment. PMID:26738081

  11. Eye development.

    PubMed

    Baker, Nicholas E; Li, Ke; Quiquand, Manon; Ruggiero, Robert; Wang, Lan-Hsin

    2014-06-15

    The eye has been one of the most intensively studied organs in Drosophila. The wealth of knowledge about its development, as well as the reagents that have been developed, and the fact that the eye is dispensable for survival, also make the eye suitable for genetic interaction studies and genetic screens. This article provides a brief overview of the methods developed to image and probe eye development at multiple developmental stages, including live imaging, immunostaining of fixed tissues, in situ hybridizations, and scanning electron microscopy and color photography of adult eyes. Also summarized are genetic approaches that can be performed in the eye, including mosaic analysis and conditional mutation, gene misexpression and knockdown, and forward genetic and modifier screens. PMID:24784530

  12. EYE DEVELOPMENT

    PubMed Central

    Baker, Nicholas E.; Li, Ke; Quiquand, Manon; Ruggiero, Robert; Wang, Lan-Hsin

    2014-01-01

    The eye has been one of the most intensively studied organs in Drosophila. The wealth of knowledge about its development, as well as the reagents that have been developed, and the fact that the eye is dispensable for survival, also make the eye suitable for genetic interaction studies and genetic screens. This chapter provides a brief overview of the methods developed to image and probe eye development at multiple developmental stages, including live imaging, immunostaining of fixed tissues, in situ hybridizations, and scanning electron microscopy and color photography of adult eyes. Also summarized are genetic approaches that can be performed in the eye, including mosaic analysis and conditional mutation, gene misexpression and knockdown, and forward genetic and modifier screens. PMID:24784530

  13. Probabilistic modeling of eye movement data during conjunction search via feature-based attention.

    PubMed

    Rutishauser, Ueli; Koch, Christof

    2007-01-01

    Where the eyes fixate during search is not random; rather, gaze reflects the combination of information about the target and the visual input. It is not clear, however, what information about a target is used to bias the underlying neuronal responses. We here engage subjects in a variety of simple conjunction search tasks while tracking their eye movements. We derive a generative model that reproduces these eye movements and calculate the conditional probabilities that observers fixate, given the target, on or near an item in the display sharing a specific feature with the target. We use these probabilities to infer which features were biased by top-down attention: Color seems to be the dominant stimulus dimension for guiding search, followed by object size, and lastly orientation. We use the number of fixations it took to find the target as a measure of task difficulty. We find that only a model that biases multiple feature dimensions in a hierarchical manner can account for the data. Contrary to common assumptions, memory plays almost no role in search performance. Our model can be fit to average data of multiple subjects or to individual subjects. Small variations of a few key parameters account well for the intersubject differences. The model is compatible with neurophysiological findings of V4 and frontal eye fields (FEF) neurons and predicts the gain modulation of these cells. PMID:17685788

  14. Advanced Clinical Imaging and Tissue-based Biomarkers of the Eye for Toxicology Studies in Minipigs.

    PubMed

    Atzpodien, Elke-Astrid; Jacobsen, Bjoern; Funk, Juergen; Altmann, Bernd; Silva Munoz, Manuel A; Singer, Thomas; Gyger, Cyrill; Hasler, Pascal; Maloca, Peter

    2016-04-01

    There is increased interest to use minipigs in ocular toxicology studies due to their anatomical similarities with human eyes and as a substitute for nonhuman primates. This requires adaptation of enhanced optical coherence tomography (OCT) techniques and of ocular relevant immunohistochemistry (IHC) or in situ hybridization (ISH) markers to porcine eyes. In this study, OCT and OCT angiography (AngioOCT) were performed on adult Göttingen minipigs. To increase structural information on retinal and choroidal vasculature, OCT data were speckle denoized and choroidal blood vessels were segmented with threshold filtering. In addition, we established a set of IHC and ISH markers on Davidson's fixed paraffin-embedded minipig eyes: neurofilament-160, neuronal nuclei, calretinin, protein kinase C-α, vimentin, glial fibrillary acidic protein, glutamine synthetase, ionized calcium-binding adaptor molecule-1, rhodopsin, synaptophysin, postsynaptic density protein-95, retinal pigment epithelium (RPE)-specific protein-65, von Willebrand factor, α-smooth muscle actin, desmin, and Ki-67, thus enabling visualization of retinal neuronal and glial cells, photoreceptors, synapses, RPE, blood vessels, myocytes, macrophages, or cell proliferation. Using ISH, transcripts of vascular endothelial growth factor A, angiopoietin-2, and endothelial tyrosine kinase were visualized. This article describes for the first time in minipig eyes speckle noise-free OCT, AngioOCT, and a set of IHC/ISH markers on Davidson's fixed paraffin-embedded tissues and helps to establish the minipig for ocular toxicology and pharmacology studies. PMID:26680760

  15. Similarity-Based Interference during Language Comprehension: Evidence from Eye Tracking during Reading

    ERIC Educational Resources Information Center

    Gordon, Peter C.; Hendrick, Randall; Johnson, Marcus; Lee, Yoonhyoung

    2006-01-01

    The nature of working memory operation during complex sentence comprehension was studied by means of eye-tracking methodology. Readers had difficulty when the syntax of a sentence required them to hold 2 similar noun phrases (NPs) in working memory before syntactically and semantically integrating either of the NPs with a verb. In sentence …

  16. A novel attention training paradigm based on operant conditioning of eye gaze: Preliminary findings.

    PubMed

    Price, Rebecca B; Greven, Inez M; Siegle, Greg J; Koster, Ernst H W; De Raedt, Rudi

    2016-02-01

    Inability to engage with positive stimuli is a widespread problem associated with negative mood states across many conditions, from low self-esteem to anhedonic depression. Though attention retraining procedures have shown promise as interventions in some clinical populations, novel procedures may be necessary to reliably attenuate chronic negative mood in refractory clinical populations (e.g., clinical depression) through, for example, more active, adaptive learning processes. In addition, a focus on individual difference variables predicting intervention outcome may improve the ability to provide such targeted interventions efficiently. To provide preliminary proof-of-principle, we tested a novel paradigm using operant conditioning to train eye gaze patterns toward happy faces. Thirty-two healthy undergraduates were randomized to receive operant conditioning of eye gaze toward happy faces (train-happy) or neutral faces (train-neutral). At the group level, the train-happy condition attenuated sad mood increases following a stressful task, in comparison to train-neutral. In individual differences analysis, greater physiological reactivity (pupil dilation) in response to happy faces (during an emotional face-search task at baseline) predicted decreased mood reactivity after stress. These Preliminary results suggest that operant conditioning of eye gaze toward happy faces buffers against stress-induced effects on mood, particularly in individuals who show sufficient baseline neural engagement with happy faces. Eye gaze patterns to emotional face arrays may have a causal relationship with mood reactivity. Personalized medicine research in depression may benefit from novel cognitive training paradigms that shape eye gaze patterns through feedback. Baseline neural function (pupil dilation) may be a key mechanism, aiding in iterative refinement of this approach. PMID:26389646

  17. Liquid Crystal based adaptive optics system to compensate both low and high order aberrations in a model eye

    NASA Astrophysics Data System (ADS)

    Mu, Quanquan; Cao, Zhaoliang; Li, Dayu; Hu, Lifa; Xuan, Li

    2007-02-01

    Based on a simple eye model system, a high resolution adaptive optics retina imaging system was built to demonstrate the availability of using liquid crystal devices as a wave-front corrector for both low and high order aberrations. Myopia glass was used to introduce large low order aberrations. A fiber bundle was used to simulate the retina. After correction, its image at different diopters became very clear. We can get a root mean square (RMS) correction precision of lower than 0.049λ (λ=0.63μm) for over to 10 diopters and the modulation transfer function (MTF) retains 511p/mm, which is nearly the diffraction limited resolution for a 2.7mm pupil diameter. The closed loop bandwidth was nearly 4 Hz, which is capable to track most of the aberration dynamics in a real eye.

  18. Trehalose-Based Eye Drops Preserve Viability and Functionality of Cultured Human Corneal Epithelial Cells during Desiccation

    PubMed Central

    Hill-Bator, Aneta; Misiuk-Hojło, Marta; Marycz, Krzysztof; Grzesiak, Jakub

    2014-01-01

    This paper presents the evaluation of cytoprotective ability of trehalose-based eye drops in comparison with commercially available preparations during the experimental desiccation of cultured human corneal epithelial cells. Cultured human corneal epithelial cells (hCEC) underwent incubation with 7 different, commercially available medicaments used commonly in dry eye syndrome treatment, followed by desiccation trial performed on air under the flow hood for 5, 15, 30, and 45 minutes. Cell viability was quantified by live/dead fluorescent assay, while the presence of apoptotic cells was estimated by immunofluorescent staining for active caspase 3 protein. The preservation of membrane functions was evaluated using neutral red staining, while the preservation of proper morphology and phenotype was determined by fluorescent staining for actin filaments, nuclei, and p63 protein. The trehalose-based eye drops showed the highest efficiency in prevention of cell death from desiccation; moreover, this preparation preserved the normal cellular morphology, functions of cell membrane, and proliferative activity more effectively than other tested medicaments. PMID:24995283

  19. Eye Injuries at Home

    MedlinePlus

    ... Patient Stories Español Eye Health / Tips & Prevention Eye Injuries Sections Preventing Eye Injuries Recognizing and Treating Eye ... Sports Eye Injuries by the Numbers — Infographic Eye Injuries at Home Reviewed by: Brenda Pagan-Duran MD ...

  20. An insect eye-based image sensor with very large field of view

    NASA Astrophysics Data System (ADS)

    Moens, Els; Meuret, Youri; Ottevaere, Heidi; Sarkar, Mukul; San Segundo Bello, David; Merken, Patrick; Thienpont, Hugo

    2010-05-01

    In this paper we discuss the design of a novel miniaturized image sensor based on the working principle of insect facet eyes. The main goals are to design an imaging system which captures a large field of view (FOV) and to find a good trade-off between image resolution and sensitivity. To capture a total FOV of 124°, we split up this FOV into 25 different zones. Each of these angular zones is imaged by an isolated optical channel on our image sensor. There is an overlap between the zones to cover the full FOV but the different zones are imaged on separated regions at the image sensor. Every optical channel in the designed component consists of two lenses that are tilted with respect to each other and the optical axis. Because of this tilt of the lenses, we are able to minimize field curvature and distortion in the obtained images at the detector, and have an angular resolution below 1°. The optical system was implemented and optimized in the ray-tracing program ASAP. The parameters (in one channel) that are optimized to obtain this large FOV with a good image resolution and sensitivity are the radius of curvature of the two lenses, their conical factor and their tilt in two directions with respect to the optical axis of the complete system. The lenses are each placed on a pedestal that connects the lens to a planar substrate. We also add absorbing tubes that connect the two lenses in one channel to eliminate stray-light between different optical channels. The obtained image quality of the design is analyzed using our simulation model. This is determined by different parameters as there are: modulation transfer function, distortion, sensitivity, angular resolution, energy distribution in each channel and channel overlap. The modulation transfer function shows us that maximum contrast in the image is reached up to 0.3LP/°, distortion is maximal 21% in one of the 25 different channels, the sensitivity is 0.3% and the resolution is better than 1°.

  1. A Divalent PAMAM-Based Matrix Metalloproteinase/Carbonic Anhydrase Inhibitor for the Treatment of Dry Eye Syndrome.

    PubMed

    Richichi, B; Baldoneschi, V; Burgalassi, S; Fragai, M; Vullo, D; Akdemir, A; Dragoni, E; Louka, A; Mamusa, M; Monti, D; Berti, D; Novellino, E; De Rosa, G; Supuran, C T; Nativi, C

    2016-01-26

    Synthetic sulfonamide derivatives are a class of potent matrix metalloproteinase inhibitors (MMPI) that have potential for the treatment of diseases related to uncontrolled expression of these enzymes. The lack of selectivity of the large majority of such inhibitors, leading to the inhibition of MMPs in tissues other than the targeted one, has dramatically reduced the therapeutic interest in MMPIs. The recent development of efficient drug delivery systems that allow the transportation of a selected drug to its site of action has opened the way to new perspectives in the use of MMPIs. Here, a PAMAM-based divalent dendron with two sulfonamidic residues was synthesized. This nanomolar inhibitor binds to the catalytic domain of two MMPs as well as to the transmembrane human carbonic anhydrases (hCAs) XII, which is present in the eye and considered an antiglaucoma target. In the animal model of an experimental dry eye, no occurrence of dotted staining in eyes treated with our inhibitor was observed, indicating no symptoms of corneal desiccation. PMID:26692423

  2. Dry Eye

    MedlinePlus

    ... surgery, called punctal cautery, is recommended to permanently close the drainage holes. The procedure helps keep the limited volume of tears on the eye for a longer period of time. In some patients with dry eye, supplements or dietary sources (such as tuna fish) of omega-3 fatty ...

  3. Eye Complications

    MedlinePlus

    ... the cornea, which focuses light while protecting the eye. After light passes through the cornea, it travels through a ... and have them progress faster. With cataracts, the eye's clear lens clouds, blocking light. To help deal with mild cataracts, you may ...

  4. Fiber-based polarization-sensitive OCT for birefringence imaging of the anterior eye segment.

    PubMed

    Yamanari, Masahiro; Tsuda, Satoru; Kokubun, Taiki; Shiga, Yukihiro; Omodaka, Kazuko; Yokoyama, Yu; Himori, Noriko; Ryu, Morin; Kunimatsu-Sanuki, Shiho; Takahashi, Hidetoshi; Maruyama, Kazuichi; Kunikata, Hiroshi; Nakazawa, Toru

    2015-02-01

    We demonstrate a prototype system of polarization-sensitive optical coherence tomography (PS-OCT) designed for clinical studies of the anterior eye segment imaging. The system can measure Jones matrices of the sample with depth-multiplexing of two orthogonal incident polarizations and polarization-sensitive detection. An optical clock is generated using a quadrature modulator and a logical circuit to double the clock frequency. Systematic artifacts in measured Jones matrices are theoretically analyzed and numerically compensated using signals at the surface of the sample. Local retardation images of filtering blebs after trabeculectomy show improved visualization of subconjunctival tissue, sclera, and scar tissue of the bleb wall in the anterior eye segment. PMID:25780730

  5. Fiber-based polarization-sensitive OCT for birefringence imaging of the anterior eye segment

    PubMed Central

    Yamanari, Masahiro; Tsuda, Satoru; Kokubun, Taiki; Shiga, Yukihiro; Omodaka, Kazuko; Yokoyama, Yu; Himori, Noriko; Ryu, Morin; Kunimatsu-Sanuki, Shiho; Takahashi, Hidetoshi; Maruyama, Kazuichi; Kunikata, Hiroshi; Nakazawa, Toru

    2015-01-01

    We demonstrate a prototype system of polarization-sensitive optical coherence tomography (PS-OCT) designed for clinical studies of the anterior eye segment imaging. The system can measure Jones matrices of the sample with depth-multiplexing of two orthogonal incident polarizations and polarization-sensitive detection. An optical clock is generated using a quadrature modulator and a logical circuit to double the clock frequency. Systematic artifacts in measured Jones matrices are theoretically analyzed and numerically compensated using signals at the surface of the sample. Local retardation images of filtering blebs after trabeculectomy show improved visualization of subconjunctival tissue, sclera, and scar tissue of the bleb wall in the anterior eye segment. PMID:25780730

  6. Eye fixation during multiple object attention is based on a representation of discrete spatial foci.

    PubMed

    Fluharty, Meg; Jentzsch, Ines; Spitschan, Manuel; Vishwanath, Dhanraj

    2016-01-01

    We often look at and attend to several objects at once. How the brain determines where to point our eyes when we do this is poorly understood. Here we devised a novel paradigm to discriminate between different models of spatial selection guiding fixation. In contrast to standard static attentional tasks where the eye remains fixed at a predefined location, observers selected their own preferred fixation position while they tracked static targets that were arranged in specific geometric configurations and which changed identity over time. Fixations were best predicted by a representation of discrete spatial foci, not a polygonal grouping, simple 2-foci division of attention or a circular spotlight. Moreover, attentional performance was incompatible with serial selection. Together with previous studies, our findings are compatible with a view that attentional selection and fixation rely on shared spatial representations and suggest a more nuanced definition of overt vs. covert attention. PMID:27561413

  7. Eye fixation during multiple object attention is based on a representation of discrete spatial foci

    PubMed Central

    Fluharty, Meg; Jentzsch, Ines; Spitschan, Manuel; Vishwanath, Dhanraj

    2016-01-01

    We often look at and attend to several objects at once. How the brain determines where to point our eyes when we do this is poorly understood. Here we devised a novel paradigm to discriminate between different models of spatial selection guiding fixation. In contrast to standard static attentional tasks where the eye remains fixed at a predefined location, observers selected their own preferred fixation position while they tracked static targets that were arranged in specific geometric configurations and which changed identity over time. Fixations were best predicted by a representation of discrete spatial foci, not a polygonal grouping, simple 2-foci division of attention or a circular spotlight. Moreover, attentional performance was incompatible with serial selection. Together with previous studies, our findings are compatible with a view that attentional selection and fixation rely on shared spatial representations and suggest a more nuanced definition of overt vs. covert attention. PMID:27561413

  8. Tracking device of multiple targets based on IR fish-eye system

    NASA Astrophysics Data System (ADS)

    Li, Gang; Lu, Xuguang; He, Yongqiang; Shen, HongBin; Wang, Yuanbo; Li, Li

    2009-11-01

    A tracking device of multiple target is proposed, whose field range reaches hemisphere airspace(sr) because of the using of IR Fish-eye system. The infrared ray is collected by Fish-eye lens, by this way can get the thermal image about the whole space, whose range depends on the lens used. Thanks to the Fish-eye system and Ptsi staring focal plane array, the tracking device can get a big range, that means can get multiple target at one time. Depends on the algorithm adopted to process the image has been gotten, the tracking device specify some points with intensive ray which means elevated temperature, and that will be the targets. At the next step after targets detection, the algorithm will compute out the speed and orientation of every target, then figure out a quotient-for-danger about every target. With this quotient, the algorithm can judge which one is the most dangerous from those flying to us, and it should be treated firstly, then the less dangerous ones, etc. To ensure the whole system run at real-time, all of the processing has to be finished at a moment. A TM320 DSP is adopted to run the algorithm. The result will be displayed at a LCD with every target labeled by their quotient-for-danger. The reaction speed and precision of this tracking device has been proved on our multiple target experiment platform.

  9. Healthy Eyes in Schools: An Evaluation of a School and Community-Based Intervention to Promote Eye Health in Rural Timor-Leste

    ERIC Educational Resources Information Center

    Hobday, Karen; Ramke, Jacqueline; du Toit, Rènée; Pereira, Sara M.

    2015-01-01

    Objective: To assess whether there was an improvement in the knowledge, attitudes and practices of students after the Healthy Eyes in Schools Project intervention and to complete a process evaluation to inform future implementation of health promotion interventions. Design: A descriptive, mixed-methods design was used, including questionnaires and…

  10. Development of a hybrid mental speller combining EEG-based brain-computer interface and webcam-based eye-tracking.

    PubMed

    Lee, Jun-Hak; Lim, Jeong-Hwan; Hwang, Han-Jeong; Im, Chang-Hwan

    2013-01-01

    The main goal of this study was to develop a hybrid mental spelling system combining a steady-state visual evoked potential (SSVEP)-based brain-computer interface (BCI) technology and a webcam-based eye-tracker, which utilizes information from the brain electrical activity and eye gaze direction at the same time. In the hybrid mental spelling system, a character decoded using SSVEP was not typed if the position of the selected character was not matched with the eye direction information ('left' or 'right') obtained from the eye-tracker. Thus, the users did not need to correct a misspelled character using a 'BACKSPACE' key. To verify the feasibility of the developed hybrid mental spelling system, we conducted online experiments with ten healthy participants. Each participant was asked to type 15 English words consisting of 68 characters. As a result, 16.6 typing errors could be prevented on average, demonstrating that the implemented hybrid mental spelling system could enhance the practicality of our mental spelling system. PMID:24110169

  11. Towards Quantum Experiments with Human Eyes as Detectors Based on Cloning via Stimulated Emission

    NASA Astrophysics Data System (ADS)

    Sekatski, Pavel; Brunner, Nicolas; Branciard, Cyril; Gisin, Nicolas; Simon, Christoph

    2009-09-01

    We show theoretically that a large Bell inequality violation can be obtained with human eyes as detectors, in a “micro-macro” experiment where one photon from an entangled pair is greatly amplified via stimulated emission. The violation is robust under photon loss. This leads to an apparent paradox, which we resolve by noting that the violation proves the existence of entanglement before the amplification. The same is true for the micro-macro experiments performed so far with conventional detectors. However, we also prove that there is genuine micro-macro entanglement even for high loss.

  12. Healthy Eyes

    MedlinePlus

    ... Programs Training and Jobs Home > Healthy Eyes Healthy Vision Diabetes Diabetes Home How Much Do You Know? ... seeing your best. Read more. What are common vision problems? Some of the most common vision problems ...

  13. Eye Allergies

    MedlinePlus

    ... MD Mar. 01, 2015 Eye allergies, called allergic conjunctivitis , are a common condition that occurs when the ... with tearing and burning. Unlike bacterial or viral conjunctivitis, allergic conjunctivitis is not spread from person to ...

  14. Eye emergencies

    MedlinePlus

    ... and there is a good chance of recovery. Alkaline substances -- such as lime, lye, drain cleaners, and ... at high speed by machining, grinding, or hammering metal have the highest risk of injuring the eye. ...

  15. Eye Infections

    MedlinePlus

    ... Health Issues Conditions Abdominal ADHD Allergies & Asthma Autism Cancer Chest & Lungs Chronic Conditions Cleft & Craniofacial Developmental Disabilities Ear Nose & Throat Emotional Problems Eyes Fever From Insects or Animals Genitals and Urinary Tract Glands & Growth ...

  16. Black Eye

    MedlinePlus

    ... Aug 30, 2016 Toddlers Most at Risk of Chemical Burns to Eyes Aug 26, 2016 Firework Blinds Teenager, Severs Hand Jun 29, ... at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms of Service For ...

  17. Linear fitting interpolation based on FOV division for correcting wide angle fish-eye lens distortion

    NASA Astrophysics Data System (ADS)

    Li, An; Wu, Yi-si; Chen, Chi; Zheng, Zhen-rong

    2015-09-01

    The wide angle lens, like fish eye lens, suffers great optical distortion that causes severe deformation of the real world. A method to correct the strong distortion was presented in this work. Due to the nonlinear distribution of the distortion, linear algorithms are generally not under consideration to establish the math model of distorted-to-ideal images. However, this method employed the calibration pattern that comprised of regular array of dots to divides the full field of view (FOV) to subsections, each subsection is a small FOV, the mapping parameters between the distorted image and ideal image in each small FOV can be calculated by employing the very simple linear polynomial. Thus, applying the determined parameters to their corresponding sub-FOVs, respectively, all the ideal pixel coordinates of the distorted image can be obtained. The method employed linear polynomial characterizes the geometric deformation between the distorted and ideal images directly. Therefore, it contains both of radial distortion and tangential distortion and there is no need of concerning any intrinsic or extrinsic parameters of the optical systems. So, this algorithm reliefs the computational work that employed by conventional radial models and other mathematical models. Experiments performed on off-axis optical systems which exist complicated distortion, such as the head mounted displays (HMDs), had already yielded accurate correcting results. Likewise, in this paper, the experiments refer to the fish-eye lens also verify the effectiveness and flexibility of this method, as well, high correcting accuracy is achieved.

  18. Ion therapy for uveal melanoma in new human eye phantom based on GEANT4 toolkit.

    PubMed

    Mahdipour, Seyed Ali; Mowlavi, Ali Asghar

    2016-01-01

    Radiotherapy with ion beams like proton and carbon has been used for treatment of eye uveal melanoma for many years. In this research, we have developed a new phantom of human eye for Monte Carlo simulation of tumors treatment to use in GEANT4 toolkit. Total depth-dose profiles for the proton, alpha, and carbon incident beams with the same ranges have been calculated in the phantom. Moreover, the deposited energy of the secondary particles for each of the primary beams is calculated. The dose curves are compared for 47.8MeV proton, 190.1MeV alpha, and 1060MeV carbon ions that have the same range in the target region reaching to the center of tumor. The passively scattered spread-out Bragg peak (SOBP) for each incident beam as well as the flux curves of the secondary particles including neutron, gamma, and positron has been calculated and compared for the primary beams. The high sharpness of carbon beam׳s Bragg peak with low lateral broadening is the benefit of this beam in hadrontherapy but it has disadvantages of dose leakage in the tail after its Bragg peak and high intensity of neutron production. However, proton beam, which has a good conformation with tumor shape owing to the beam broadening caused by scattering, can be a good choice for the large-size tumors. PMID:26831752

  19. Eye region-based fusion technique of thermal and dark visual images for human face recognition

    NASA Astrophysics Data System (ADS)

    Bhowmik, Mrinal Kanti; Bhattacharjee, Debotosh; Basu, Dipak Kumar; Nasipuri, Mita

    2012-07-01

    We present an approach for human face recognition using eye region extraction/replacement method under low illumination and varying expression conditions. For conducting experiments, two different sets of face images, namely visual and corresponding thermal, are used from Imaging, Robotics, and Intelligent Systems (IRIS) thermal/visual face data. A decomposition and reconstruction technique of Daubechies wavelet co-efficient (db4) is used to generate the fused image by replacing the eye region in the visual image with the same region from the corresponding thermal image. After that, independent component analysis over the natural logarithm domain (Log-ICA) is used for feature extraction/dimensionality reduction, and finally, a classifier is used to classify the fused face images. Two different image sets, i.e., training and test image sets, are mainly prepared using the IRIS thermal/visual face database for finding the accuracy of the proposed system. Experimental results show the proposed method is more efficient than other image fusion techniques which have used region extraction techniques for dark faces.

  20. Are higher blood mercury levels associated with dry eye symptoms in adult Koreans? A population-based cross-sectional study

    PubMed Central

    Chung, So-Hyang

    2016-01-01

    Objectives The purpose of this study was to investigate whether blood mercury concentrations associated with the presence of dry eye symptoms in a nationally representative Korean population. Methods Population-based prospective cross-sectional study using the heavy metal data set of the 2010–2012 Korean National Health and Nutrition Examination Survey (KNHANES). A total of 4761 adult Koreans were the eligible population in this study. Of the 7162 survey participants, 2401 were excluded because they were <19 years of age, there were missing data in the heavy metal data set, or they had diabetes, rheumatoid arthritis, thyroid disease, asthma, depression and/or under-the-eye surgery. Blood mercury levels were measured on the day the participants completed a questionnaire regarding the presence of dry eye symptoms (persistent dryness or eye irritation). The population was divided into low and high groups by median level (4.26 and 2.89 µg/L for males and females, respectively). Results Self-reported dry eye symptoms were present in 13.0% of the cohort. Participants with dry eye symptoms were significantly more likely to have blood mercury levels exceeding the median than those without dry eye symptoms (45.7% vs 51.7%, p=0.021). Logistic regression analysis showed that, after adjusting for age, gender, education, total household income, smoking status, heavy alcohol use, sleep time, perceived stress status, total cholesterol levels and atopy history, dry eye symptoms were significantly associated with blood mercury levels that exceeded the median (reference: lower mercury group; OR, 1.324; 95% CI 1.059 to 1.655; p<0.05). Conclusions High blood mercury levels were associated with dry eye symptoms in a nationally representative Korean population. PMID:27121705

  1. Aging and Your Eyes

    MedlinePlus

    ... Your Eyes Heath and Aging Aging and Your Eyes Steps to Protect Your Eyesight Common Eye Problems ... weight can also help protect your vision. Common Eye Problems The following common eye problems can be ...

  2. Improving video captioning for deaf and hearing-impaired people based on eye movement and attention overload

    NASA Astrophysics Data System (ADS)

    Chapdelaine, C.; Gouaillier, V.; Beaulieu, M.; Gagnon, L.

    2007-02-01

    Deaf and hearing-impaired people capture information in video through visual content and captions. Those activities require different visual attention strategies and up to now, little is known on how caption readers balance these two visual attention demands. Understanding these strategies could suggest more efficient ways of producing captions. Eye tracking and attention overload detections are used to study these strategies. Eye tracking is monitored using a pupilcenter- corneal-reflection apparatus. Afterward, gaze fixation is analyzed for each region of interest such as caption area, high motion areas and faces location. This data is also used to identify the scanpaths. The collected data is used to establish specifications for caption adaptation approach based on the location of visual action and presence of character faces. This approach is implemented in a computer-assisted captioning software which uses a face detector and a motion detection algorithm based on the Lukas-Kanade optical flow algorithm. The different scanpaths obtained among the subjects provide us with alternatives for conflicting caption positioning. This implementation is now undergoing a user evaluation with hearing impaired participants to validate the efficiency of our approach.

  3. Screening neonatal jaundice based on the sclera color of the eye using digital photography

    PubMed Central

    Leung, Terence S.; Kapur, Karan; Guilliam, Ashley; Okell, Jade; Lim, Bee; MacDonald, Lindsay W.; Meek, Judith

    2015-01-01

    A new screening technique for neonatal jaundice is proposed exploiting the yellow discoloration in the sclera. It involves taking digital photographs of newborn infants’ eyes (n = 110) and processing the pixel colour values of the sclera to predict the total serum bilirubin (TSB) levels. This technique has linear and rank correlation coefficients of 0.75 and 0.72 (both p<0.01) with the measured TSB. The mean difference ( ± SD) is 0.00 ± 41.60 µmol/l. The receiver operating characteristic curve shows that this technique can identify subjects with TSB above 205 µmol/l with sensitivity of 1.00 and specificity of 0.50, showing its potential as a screening device. PMID:26601015

  4. Screening neonatal jaundice based on the sclera color of the eye using digital photography.

    PubMed

    Leung, Terence S; Kapur, Karan; Guilliam, Ashley; Okell, Jade; Lim, Bee; MacDonald, Lindsay W; Meek, Judith

    2015-11-01

    A new screening technique for neonatal jaundice is proposed exploiting the yellow discoloration in the sclera. It involves taking digital photographs of newborn infants' eyes (n = 110) and processing the pixel colour values of the sclera to predict the total serum bilirubin (TSB) levels. This technique has linear and rank correlation coefficients of 0.75 and 0.72 (both p<0.01) with the measured TSB. The mean difference ( ± SD) is 0.00 ± 41.60 µmol/l. The receiver operating characteristic curve shows that this technique can identify subjects with TSB above 205 µmol/l with sensitivity of 1.00 and specificity of 0.50, showing its potential as a screening device. PMID:26601015

  5. The role of character-based knowledge in online narrative comprehension: evidence from eye movements and ERPs.

    PubMed

    Filik, Ruth; Leuthold, Hartmut

    2013-04-19

    Little is known about the on-line evaluation of information relating to well-known story characters during text comprehension. For example, it is not clear in how much detail readers represent character-based information, and the time course over which this information is utilized during on-line language comprehension. We describe an event-related potential (ERP) study (Experiment 1) and an eye-tracking study (Experiment 2) investigating whether, and when, readers utilize their prior knowledge of a character in processing event information. Participants read materials in which an event was described that either did or did not fit with the character's typical behavior. ERPs elicited by the critical word revealed an N400 effect when the action described did not fit with the character's typical behavior. Results from early eye movement measures supported these findings, and later measures suggested that such violations were more easily accommodated for well-known fictional characters than real-world characters. PMID:23419895

  6. Relationships between high resolution RapidEye based fPAR and MODIS vegetation indices in a heterogeneous agricultural region

    NASA Astrophysics Data System (ADS)

    Fritsch, Sebastian; Machwitz, Miriam; Conrad, Christopher; Dech, Stefan

    2011-11-01

    The Moderate Imaging Spectroradiometer (MODIS) provides operational products of the Normalized Difference Vegetation Index (NDVI), the Enhanced Vegetation Index (EVI), and the fraction of photosynthetic active radiation (fPAR). FPAR can be used in productivity models, but agricultural applications depend on sub-pixel heterogeneity. Examples for heterogeneous areas are the irrigation systems of the inner Aral Sea Basin, where the 1 km fPAR product proved less suited. An alternative can be to upscale fPAR to the 250 m scale, but there are few studies evaluating this approach. In this study, the use of MODIS 250 m NDVI and EVI for this approach was investigated in an irrigation system in western Uzbekistan. The analysis was based on high resolution fPAR maps and a crop map for the growing season 2009, derived from ground measurements and multitemporal RapidEye data. The data was used to explore statistical relationships between RapidEye fPAR and MODIS NDVI/EVI with respect to spatial heterogeneity. The correlations varied between products (daily NDVI, 8-day NDVI, 16-day NDVI/EVI), with results suggesting that 8-day NDVI performed best. The analyses and the compiled fPAR maps show that, compared to 1 km MODIS fPAR, the 250 m scale is more homogeneous, allows for crop-specific analyses, and better captures the spatial patterns in the study region.

  7. Acupuncture Therapy Is More Effective Than Artificial Tears for Dry Eye Syndrome: Evidence Based on a Meta-Analysis

    PubMed Central

    Yang, Lei; Yu, Hong; Song, Hui

    2015-01-01

    Background. The efficacy of acupuncture in dry eye syndrome patients remains controversial. Methods. Pubmed, Ovid, Cochrane libraries, CNKI, Wanfang, and CQVIP databases were electronically searched until October 1, 2014. Outcomes including tear break-up time (BUT), Schirmer I test (SIT), and cornea fluorescein staining (CFS) were analyzed. A meta-analysis was performed using both fixed- and random-effects models based on heterogeneity across studies. Results. Seven studies were included in this study; 198 and 185 patients were randomly treated with acupuncture and artificial tears, respectively. The overall BUT of patients in acupuncture group was significantly longer than that of the artificial tears group after treatment (P < 0.00001). The SIT was significantly higher in the acupuncture group than that in the artificial tears group after treatment (P = 0.001). The CFS of patients in acupuncture group was significantly improved compared to that in artificial group (P < 0.0001). Conclusions. Acupuncture therapy is effective for the dry eye patients, partly better than artificial tear treatment. PMID:25960747

  8. Mindless reading revisited: an analysis based on the SWIFT model of eye-movement control.

    PubMed

    Nuthmann, Antje; Engbert, Ralf

    2009-02-01

    In this article, we revisit the mindless reading paradigm from the perspective of computational modeling. In the standard version of the paradigm, participants read sentences in both their normal version as well as the transformed (or mindless) version where each letter is replaced with a z. z-String scanning shares the oculomotor requirements with reading but none of the higher-level lexical and semantic processes. Here we use the z-string scanning task to validate the SWIFT model of saccade generation [Engbert, R., Nuthmann, A., Richter, E., & Kliegl, R. (2005). SWIFT: A dynamical model of saccade generation during reading. Psychological Review, 112(4), 777-813] as an example for an advanced theory of eye-movement control in reading. We test the central assumption of spatially distributed processing across an attentional gradient proposed by the SWIFT model. Key experimental results like prolonged average fixation durations in z-string scanning compared to normal reading and the existence of a string-length effect on fixation durations and probabilities were reproduced by the model, which lends support to the model's assumptions on visual processing. Moreover, simulation results for patterns of regressive saccades in z-string scanning confirm SWIFT's concept of activation field dynamics for the selection of saccade targets. PMID:19026673

  9. The advantage of word-based processing in Chinese reading: evidence from eye movements.

    PubMed

    Li, Xingshan; Gu, Junjuan; Liu, Pingping; Rayner, Keith

    2013-05-01

    In 2 experiments, we tested the prediction that reading is more efficient when characters belonging to a word are presented simultaneously than when they are not in Chinese reading using a novel variation of the moving window paradigm (McConkie & Rayner, 1975). In Experiment 1, we found that reading was slowed down when Chinese readers could not see characters belonging to a word simultaneously compared to when they could do so. In Experiment 2, when Chinese readers could choose whether the 2 characters in the moving window contained a word or 2 characters that did not constitute a word, they had a clear tendency to look at 2 characters belonging to a word simultaneously. The results of the current study provide strong evidence that character processing is affected by word knowledge and the processing of other characters belonging to the same word in Chinese reading, and add to a growing body of evidence demonstrating that words do have psychological reality for Chinese readers. The results also suggest that the eye movement control strategy of Chinese readers is rather flexible in that it can be adjusted online to modify the characteristics of the window. PMID:23088542

  10. Eye and orbit ultrasound

    MedlinePlus

    Echography - eye orbit; Ultrasound - eye orbit; Ocular ultrasonography; Orbital ultrasonography ... ophthalmology department of a hospital or clinic. Your eye is numbed with medicine (anesthetic drops). The ultrasound ...

  11. Fabrication and characterization of nitride-based blue light-emitting diodes on moth-eye patterned sapphire substrate (MPSS)

    NASA Astrophysics Data System (ADS)

    Tsuchiya, T.; Umeda, S.; Sowa, Mihoko; Kondo, T.; Kitano, T.; Mori, M.; Suzuki, A.; Naniwae, K.; Sekine, H.; Iwaya, M.; Takeuchi, T.; Kamiyama, S.; Akasaki, I.

    2013-03-01

    The fabrication procedure of a moth-eye patterned sapphire substrate (MPSS), which can enhance the light extraction efficiency of nitride-based light emitting diodes (LEDs) has been examined. The optimization of surface morphology after the etching of the MPSS for high-quality GaN growth was also performed. Then, we fabricated MPSS samples with a fixed pitch of 460nm, and corn height ranging from 50 to 350nm. The light extraction efficiency of blue-LEDs grown on a series of MPSS was enhanced about 1.4 times compared with the devices grown on a flat sapphire substrate. We found that if corn height exceeds 150nm, the MPSS effect is sufficiently observed.

  12. Optical performance simulation of free-form optics for an eye implant based on a measurement data enhanced model.

    PubMed

    Sieber, Ingo; Li, Likai; Gengenbach, Ulrich; Beckert, Erik; Steinkopf, Ralf; Yi, Allen Y

    2016-08-20

    This paper describes the application of a modeling approach for precise optical performance prediction of free-form optics-based subsystems on a demonstration model of an eye implant. The simulation model is enhanced by surface data measured on the free-form lens parts. The manufacturing of the free-form lens parts is realized by two different manufacturing processes: ultraprecision diamond machining and microinjection molding. Evaluation of both processes is conducted by a simulation of the optical performance on the basis of their surface measurement comparisons with the nominal geometry. The simulation results indicate that improvements from the process optimization of microinjection molding were obtained for the best manufacturing accuracy. PMID:27556988

  13. Increased Burden of Vision Impairment and Eye Diseases in Persons with Chronic Kidney Disease — A Population-Based Study

    PubMed Central

    Wong, Chee Wai; Lamoureux, Ecosse L.; Cheng, Ching-Yu; Cheung, Gemmy Chui Ming; Tai, E. Shyong; Wong, Tien Y.; Sabanayagam, Charumathi

    2016-01-01

    Background Chronic kidney disease (CKD) has been shown to be associated with diabetic retinopathy (DR) and age-related macular degeneration (AMD), leading causes of blindness in elderly adults in previous studies. However, the association of CKD with visual impairment (VI) is not clear. We aimed to examine the association of CKD with VI and other age-related ocular diseases in a population-based sample of Asian adults. Methods We analyzed data from 10,033 adults aged 40–80 years who participated in the Singapore Epidemiology of Eye Diseases (SEED, 2004–11) Study. CKD was defined as an estimated glomerular filtration rate (eGFR) < 60 ml/min/1.73 m2 from serum creatinine. VI was defined as best-corrected visual acuity < 20/40 in the better eye. Cataract, retinopathy, DR, glaucoma and AMD were assessed using standardized ocular examination, retinal photography and visual field assessments. The associations of CKD with VI and ocular conditions were examined using logistic regression models adjusted for age, sex, race, smoking, alcohol intake, education status, body mass index, systolic blood pressure, diabetes mellitus, cholesterol levels and cardiovascular disease. Findings The prevalence of VI and ocular disease were significantly higher in participants with CKD (36.1% and 84.7%) than in those without (12.9% and 54.3%, both p < 0.001). In multivariable models, CKD was significantly associated with VI (odds ratio [95% confidence interval] = 1.34 [1.14–1.58]), any ocular disease (1.28 [1.03–1.61]), cataract (1.24 [1.01–1.52]), any retinopathy (1.77 [1.45–2.15]), and DR (1.94 [1.47–2.54]). Interpretation The burden of VI and eye diseases is high among persons with CKD. Our findings suggest that it may be useful to screen for ocular disease and VI in persons with CKD. PMID:27077127

  14. Dilating Eye Drops

    MedlinePlus

    ... Conditions Most Common Searches Adult Strabismus Amblyopia Cataract Conjunctivitis Corneal Abrasions Dilating Eye Drops Lazy eye (defined) ... Loading... Most Common Searches Adult Strabismus Amblyopia Cataract Conjunctivitis Corneal Abrasions Dilating Eye Drops Lazy eye (defined) ...

  15. Eye muscle repair - discharge

    MedlinePlus

    ... Lazy eye repair - discharge; Strabismus repair - discharge; Extraocular muscle surgery - discharge ... You or your child had eye muscle repair surgery to correct eye muscle ... term for crossed eyes is strabismus. Children most often ...

  16. Eye Movement Disorders

    MedlinePlus

    ... t work properly. There are many kinds of eye movement disorders. Two common ones are Strabismus - a disorder ... of the eyes, sometimes called "dancing eyes" Some eye movement disorders are present at birth. Others develop over ...

  17. Why Do Eyes Water?

    MedlinePlus

    ... Help White House Lunch Recipes Why Do Eyes Water? KidsHealth > For Kids > Why Do Eyes Water? Print ... out of your nose. continue Why Do Eyes Water? Eyes water for lots of different reasons besides ...

  18. How to administer eye drops and eye ointment.

    PubMed

    Shaw, Mary

    2016-05-25

    Rationale and key points Eye drops and eye ointment are the mainstay of treatment of ocular conditions. Failure to prioritise administration of these medicines can prolong the condition and may present a risk to the patient's vision. ▶ Eye drops and eye ointments are used to treat acute and chronic conditions of the eye and surrounding structures. Eye drops must be instilled before applying eye ointment, since the ointment will affect the absorption of the eye drop. ▶ Nurses require knowledge of the technique, side effects and potential interactions associated with systemically or topically applied medicines to the eye to ensure patient safety and optimum outcomes. Reflective activity Clinical skills articles can help update your practice and ensure it remains evidence based. Apply this article to your practice. Reflect on and write a short account of: 1. How this article will change your practice. 2. How you intend to develop your knowledge and skills regarding treatment of ocular conditions. Subscribers can update their reflective accounts at rcni.com/portfolio. PMID:27224628

  19. TH-E-17A-10: Markerless Lung Tumor Tracking Based On Beams Eye View EPID Images

    SciTech Connect

    Chiu, T; Kearney, V; Liu, H; Jiang, L; Foster, R; Mao, W; Rozario, T; Bereg, S; Klash, S

    2014-06-15

    Purpose: Dynamic tumor tracking or motion compensation techniques have proposed to modify beam delivery following lung tumor motion on the flight. Conventional treatment plan QA could be performed in advance since every delivery may be different. Markerless lung tumor tracking using beams eye view EPID images provides a best treatment evaluation mechanism. The purpose of this study is to improve the accuracy of the online markerless lung tumor motion tracking method. Methods: The lung tumor could be located on every frame of MV images during radiation therapy treatment by comparing with corresponding digitally reconstructed radiograph (DRR). A kV-MV CT corresponding curve is applied on planning kV CT to generate MV CT images for patients in order to enhance the similarity between DRRs and MV treatment images. This kV-MV CT corresponding curve was obtained by scanning a same CT electron density phantom by a kV CT scanner and MV scanner (Tomotherapy) or MV CBCT. Two sets of MV DRRs were then generated for tumor and anatomy without tumor as the references to tracking the tumor on beams eye view EPID images. Results: Phantom studies were performed on a Varian TrueBeam linac. MV treatment images were acquired continuously during each treatment beam delivery at 12 gantry angles by iTools. Markerless tumor tracking was applied with DRRs generated from simulated MVCT. Tumors were tracked on every frame of images and compared with expected positions based on programed phantom motion. It was found that the average tracking error were 2.3 mm. Conclusion: This algorithm is capable of detecting lung tumors at complicated environment without implanting markers. It should be noted that the CT data has a slice thickness of 3 mm. This shows the statistical accuracy is better than the spatial accuracy. This project has been supported by a Varian Research Grant.

  20. Naked-eye sensitive ELISA-like assay based on gold-enhanced peroxidase-like immunogold activity.

    PubMed

    Wang, Shasha; Chen, Zhaopeng; Choo, Jaebum; Chen, Lingxin

    2016-02-01

    A naked-eye sensitive ELISA-like assay was developed based on gold-enhanced peroxidase-like activity of gold nanoparticles (AuNPs). Using human IgG (H-IgG) as an analytical model, goat anti-human IgG antibody (anti-IgG) adsorbed on microtiter plate and AuNPs-labeled anti-IgG acted as capture antibody and detection antibody, respectively. Because the surfaces of AuNPs were blocked by protein molecules, the peroxidase-like activity of AuNPs was almost inhibited, evaluated by the catalytic oxidation of peroxidase enzyme substrate 3,3',5,5'-tetramethylbenzidine (TMB), which could produce a bright blue color in the presence of H2O2. Fortunately, the catalytic ability of AuNPs was dramatically increased by the deposition of gold due to the formation of a new gold shell on immunogold. Under optimal reaction conditions, the colorimetric immunoassay presented a good linear relationship in the range of 0.7-100 ng/mL and the limit of detection (LOD) of 0.3 ng/mL calculated by 3σ/S for UV-vis detection, and obtained LOD of 5 ng/mL for naked-eye detection. The obtained results were competitive with conventional sandwich ELISA with the LOD of 1.6 ng/mL. Furthermore, this developed colorimetric immunoassay was successfully applied to diluted human serum and fetal bovine serum samples, and predicted a broad prospect for the use of peroxidase-like activity involving nanomaterials in bioassay and diagnostics. PMID:26677026

  1. Building metamemorial knowledge over time: insights from eye tracking about the bases of feeling-of-knowing and confidence judgments

    PubMed Central

    Chua, Elizabeth F.; Solinger, Lisa A.

    2015-01-01

    Metamemory processes depend on different factors across the learning and memory time-scale. In the laboratory, subjects are often asked to make prospective feeling-of-knowing (FOK) judgments about target retrievability, or are asked to make retrospective confidence judgments (RCJs) about the retrieved target. We examined distinct and shared contributors to metamemory judgments, and how they were built over time. Eye movements were monitored during a face-scene associative memory task. At test, participants viewed a studied scene, then rated their FOK that they would remember the associated face. This was followed by a forced choice recognition test and RCJs. FOK judgments were less accurate than RCJ judgments, showing that the addition of mnemonic experience can increase metacognitive accuracy over time. However, there was also evidence that the given FOK rating influenced RCJs. Turning to eye movements, initial analyses showed that higher cue fluency was related to both higher FOKs and higher RCJs. However, further analyses revealed that the effects of the scene cue on RCJs were mediated by FOKs. Turning to the target, increased viewing time and faster viewing of the correct associate related to higher FOKs, consistent with the idea that target accessibility is a basis of FOKs. In contrast, the amount of viewing directed to the chosen face, regardless of whether it was correct, predicted higher RCJs, suggesting that choice experience is a significant contributor RCJs. We also examined covariates of the change in RCJ rating from the FOK rating, and showed that increased and faster viewing of the chosen face predicted raising one’s confidence above one’s FOK. Taken together these results suggest that metamemory judgments should not be thought of only as distinct subjective experiences, but complex processes that interact and evolve as new psychological bases for subjective experience become available. PMID:26347677

  2. Video-Based Eye Tracking to Detect the Attention Shift: A Computer Classroom Context-Aware System

    ERIC Educational Resources Information Center

    Kuo, Yung-Lung; Lee, Jiann-Shu; Hsieh, Min-Chai

    2014-01-01

    Eye and head movements evoked in response to obvious visual attention shifts. However, there has been little progress on the causes of absent-mindedness so far. The paper proposes an attention awareness system that captures the conditions regarding the interaction of eye gaze and head pose under various attentional switching in computer classroom.…

  3. Portable eye-safe ceilometers

    NASA Astrophysics Data System (ADS)

    Kryuchkov, A. V.; Grishin, A. I.; Gricuta, A. N.

    2014-11-01

    Developed and tested a simplified version of the definition of the cloud base height of the backscatter signal obtained in the laser meter height of the cloud base with eye-safe level of radiation intensity.

  4. Object-based visual attention in 8-month-old infants: evidence from an eye-tracking study.

    PubMed

    Bulf, Hermann; Valenza, Eloisa

    2013-10-01

    Visual attention is one of the infant's primary tools for gathering relevant information from the environment for further processing and learning. The space-based component of visual attention in infants has been widely investigated; however, the object-based component of visual attention has received scarce interest. This scarcity is surprising, given the importance of objects in driving infants' attention and predispositions to attend to object information. Here, we investigated the object-based component of attention in 8-month-old infants. An eye tracker measured the saccade latencies to find a target that could appear in a previously cued end of 2 bars (valid targets), in the other end of the cued bar (invalid same-object targets), or in the other bar but at the same distance from the cue (invalid different-object targets). Bars were unoccluded or partly occluded; if attention is object based, it should also operate on objects that require perceptual completion. After verifying in a sample of adults (Experiment 1) that a measure of saccade latency suitably assessed space-based and object-based attention, we tested 8-month-old infants (Experiment 2) using the same procedure. The results showed that in both adults and infants, target detection was faster for valid targets than for invalid ones (space-based effect). Moreover, for both the unoccluded and partly occluded conditions, detection was faster on invalid within-object trials than on invalid between-objects trials (object-based effect). These findings demonstrate that visual objects can operate as units of attention for infants by the age of 8 months, offering implications for cognitive development. PMID:23276133

  5. Classification of binary intentions for individuals with impaired oculomotor function: ‘eyes-closed’ SSVEP-based brain-computer interface (BCI)

    NASA Astrophysics Data System (ADS)

    Lim, Jeong-Hwan; Hwang, Han-Jeong; Han, Chang-Hee; Jung, Ki-Young; Im, Chang-Hwan

    2013-04-01

    Objective. Some patients suffering from severe neuromuscular diseases have difficulty controlling not only their bodies but also their eyes. Since these patients have difficulty gazing at specific visual stimuli or keeping their eyes open for a long time, they are unable to use the typical steady-state visual evoked potential (SSVEP)-based brain-computer interface (BCI) systems. In this study, we introduce a new paradigm for SSVEP-based BCI, which can be potentially suitable for disabled individuals with impaired oculomotor function. Approach. The proposed electroencephalography (EEG)-based BCI system allows users to express their binary intentions without needing to open their eyes. A pair of glasses with two light emitting diodes flickering at different frequencies was used to present visual stimuli to participants with their eyes closed, and we classified the recorded EEG patterns in the online experiments conducted with five healthy participants and one patient with severe amyotrophic lateral sclerosis (ALS). Main results. Through offline experiments performed with 11 participants, we confirmed that human SSVEP could be modulated by visual selective attention to a specific light stimulus penetrating through the eyelids. Furthermore, the recorded EEG patterns could be classified with accuracy high enough for use in a practical BCI system. After customizing the parameters of the proposed SSVEP-based BCI paradigm based on the offline analysis results, binary intentions of five healthy participants were classified in real time. The average information transfer rate of our online experiments reached 10.83 bits min-1. A preliminary online experiment conducted with an ALS patient showed a classification accuracy of 80%. Significance. The results of our offline and online experiments demonstrated the feasibility of our proposed SSVEP-based BCI paradigm. It is expected that our ‘eyes-closed’ SSVEP-based BCI system can be potentially used for communication of

  6. Artificial neural superposition eye.

    PubMed

    Brückner, Andreas; Duparré, Jacques; Dannberg, Peter; Bräuer, Andreas; Tünnermann, Andreas

    2007-09-17

    We propose an ultra-thin imaging system which is based on the neural superposition compound eye of insects. Multiple light sensitive pixels in the footprint of each lenslet of this multi-channel configuration enable the parallel imaging of the individual object points. Together with the digital superposition of related signals this multiple sampling enables advanced functionalities for artificial compound eyes. Using this technique, color imaging and a circumvention for the trade-off between resolution and sensitivity of ultra-compact camera devices have been demonstrated in this article. The optical design and layout of such a system is discussed in detail. Experimental results are shown which indicate the attractiveness of microoptical artificial compound eyes for applications in the field of machine vision, surveillance or automotive imaging. PMID:19547555

  7. A Featured-Based Strategy for Stereovision Matching in Sensors with Fish-Eye Lenses for Forest Environments

    PubMed Central

    Herrera, Pedro Javier; Pajares, Gonzalo; Guijarro, Maria; Ruz, José J.; Cruz, Jesús M.; Montes, Fernando

    2009-01-01

    This paper describes a novel feature-based stereovision matching process based on a pair of omnidirectional images in forest stands acquired with a stereovision sensor equipped with fish-eye lenses. The stereo analysis problem consists of the following steps: image acquisition, camera modelling, feature extraction, image matching and depth determination. Once the depths of significant points on the trees are obtained, the growing stock volume can be estimated by considering the geometrical camera modelling, which is the final goal. The key steps are feature extraction and image matching. This paper is devoted solely to these two steps. At a first stage a segmentation process extracts the trunks, which are the regions used as features, where each feature is identified through a set of attributes of properties useful for matching. In the second step the features are matched based on the application of the following four well known matching constraints, epipolar, similarity, ordering and uniqueness. The combination of the segmentation and matching processes for this specific kind of sensors make the main contribution of the paper. The method is tested with satisfactory results and compared against the human expert criterion. PMID:22303134

  8. A featured-based strategy for stereovision matching in sensors with fish-eye lenses for forest environments.

    PubMed

    Herrera, Pedro Javier; Pajares, Gonzalo; Guijarro, Maria; Ruz, José J; Cruz, Jesús M; Montes, Fernando

    2009-01-01

    This paper describes a novel feature-based stereovision matching process based on a pair of omnidirectional images in forest stands acquired with a stereovision sensor equipped with fish-eye lenses. The stereo analysis problem consists of the following steps: image acquisition, camera modelling, feature extraction, image matching and depth determination. Once the depths of significant points on the trees are obtained, the growing stock volume can be estimated by considering the geometrical camera modelling, which is the final goal. The key steps are feature extraction and image matching. This paper is devoted solely to these two steps. At a first stage a segmentation process extracts the trunks, which are the regions used as features, where each feature is identified through a set of attributes of properties useful for matching. In the second step the features are matched based on the application of the following four well known matching constraints, epipolar, similarity, ordering and uniqueness. The combination of the segmentation and matching processes for this specific kind of sensors make the main contribution of the paper. The method is tested with satisfactory results and compared against the human expert criterion. PMID:22303134

  9. Autologous serum eye drops for dry eye

    PubMed Central

    Pan, Qing; Angelina, Adla; Zambrano, Andrea; Marrone, Michael; Stark, Walter J; Heflin, Thomas; Tang, Li; Akpek, Esen K

    2014-01-01

    Background Theoretically, autologous serum eye drops (AS) have a potential advantage over traditional therapies based on the assumption that AS serve not only as a lacrimal substitute to provide lubrication, but also contain other biochemical components mimicking natural tears more closely. The application of AS in dry eye treatment has gained popularity as a second-line therapy in the treatment of dry eye. Published studies on the subject indicate that autologous serum could be an effective treatment for dry eye. Objectives To evaluate the efficacy and safety of AS compared to artificial tears for treating dry eye. Search methods We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2013, Issue 3), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLD MEDLINE, (January 1950 to April 2013), EMBASE (January 1980 to April 2013), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to April 2013), the meta Register of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We also searched the Science Citation Index Expanded database (September 2013) and reference lists of included studies. We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 15 April 2013. Selection criteria We included randomized controlled trials (RCTs) in which AS was compared to artificial tears in the treatment of dry eye in adults. Data collection and analysis Two review authors independently screened all titles and abstracts and assessed full-text articles of potentially eligible trials. Two review authors extracted data and assessed the methodological quality and characteristics of the included trials.We contacted investigators for missing data

  10. Meeting report: the road to science-based policy - ESOF through the eyes of young scientists.

    PubMed

    Sinjab, Ansam; Nöske, Katharina

    2014-12-01

    Communication and common understanding between politicians, scientists, and the society can lead to evidence-based science policy, a core principle that guides high caliber research and open innovation for a sustainable future. PMID:25346005

  11. Improving eye safety in citrus harvest crews through the acceptance of personal protective equipment, community-based participatory research, social marketing, and community health workers.

    PubMed

    Tovar-Aguilar, J Antonio; Monaghan, Paul F; Bryant, Carol A; Esposito, Andrew; Wade, Mark; Ruiz, Omar; McDermott, Robert J

    2014-01-01

    For the last 10 years, the Partnership for Citrus Workers Health (PCWH) has been an evidence-based intervention program that promotes the adoption of protective eye safety equipment among Spanish-speaking farmworkers of Florida. At the root of this program is the systematic use of community-based preventive marketing (CBPM) and the training of community health workers (CHWs) among citrus harvester using popular education. CBPM is a model that combines the organizational system of community-based participatory research (CBPR) and the strategies of social marketing. This particular program relied on formative research data using a mixed-methods approach and a multilevel stakeholder analysis that allowed for rapid dissemination, effective increase of personal protective equipment (PPE) usage, and a subsequent impact on adoptive workers and companies. Focus groups, face-to-face interviews, surveys, participant observation, Greco-Latin square, and quasi-experimental tests were implemented. A 20-hour popular education training produced CHWs that translated results of the formative research to potential adopters and also provided first aid skills for eye injuries. Reduction of injuries is not limited to the use of safety glasses, but also to the adoption of timely intervention and regular eye hygiene. Limitations include adoption in only large companies, rapid decline of eye safety glasses without consistent intervention, technological limitations of glasses, and thorough cost-benefit analysis. PMID:24911686

  12. Copula regression analysis of simultaneously recorded frontal eye field and inferotemporal spiking activity during object-based working memory.

    PubMed

    Hu, Meng; Clark, Kelsey L; Gong, Xiajing; Noudoost, Behrad; Li, Mingyao; Moore, Tirin; Liang, Hualou

    2015-06-10

    Inferotemporal (IT) neurons are known to exhibit persistent, stimulus-selective activity during the delay period of object-based working memory tasks. Frontal eye field (FEF) neurons show robust, spatially selective delay period activity during memory-guided saccade tasks. We present a copula regression paradigm to examine neural interaction of these two types of signals between areas IT and FEF of the monkey during a working memory task. This paradigm is based on copula models that can account for both marginal distribution over spiking activity of individual neurons within each area and joint distribution over ensemble activity of neurons between areas. Considering the popular GLMs as marginal models, we developed a general and flexible likelihood framework that uses the copula to integrate separate GLMs into a joint regression analysis. Such joint analysis essentially leads to a multivariate analog of the marginal GLM theory and hence efficient model estimation. In addition, we show that Granger causality between spike trains can be readily assessed via the likelihood ratio statistic. The performance of this method is validated by extensive simulations, and compared favorably to the widely used GLMs. When applied to spiking activity of simultaneously recorded FEF and IT neurons during working memory task, we observed significant Granger causality influence from FEF to IT, but not in the opposite direction, suggesting the role of the FEF in the selection and retention of visual information during working memory. The copula model has the potential to provide unique neurophysiological insights about network properties of the brain. PMID:26063909

  13. Quadcopter flight control using a low-cost hybrid interface with EEG-based classification and eye tracking.

    PubMed

    Kim, Byung Hyung; Kim, Minho; Jo, Sungho

    2014-08-01

    We propose a wearable hybrid interface where eye movements and mental concentration directly influence the control of a quadcopter in three-dimensional space. This noninvasive and low-cost interface addresses limitations of previous work by supporting users to complete their complicated tasks in a constrained environment in which only visual feedback is provided. The combination of the two inputs augments the number of control commands to enable the flying robot to travel in eight different directions within the physical environment. Five human subjects participated in the experiments to test the feasibility of the hybrid interface. A front view camera on the hull of the quadcopter provided the only visual feedback to each remote subject on a laptop display. Based on the visual feedback, the subjects used the interface to navigate along pre-set target locations in the air. The flight performance was evaluated by comparing with a keyboard-based interface. We demonstrate the applicability of the hybrid interface to explore and interact with a three-dimensional physical space through a flying robot. PMID:24880998

  14. Longitudinal trends in use of targeted therapies for treatment of malignant neoplasms of the eye: a population-based study in Taiwan

    PubMed Central

    Hsu, Jason C; Gonzalez-Gonzalez, Luis A; Lu, Vicky H; Lu, Christine Y

    2016-01-01

    Objectives This study examined the recent trend in use and costs of antineoplastic agents for treatment of eye malignancies in Taiwan from 2009 to 2012. We also forecasted use and costs of targeted therapies up to and including year 2016 based on the current patterns. Design Retrospective observational study focusing on the usage of targeted therapies for treatment of eye malignancy. Setting The monthly claims data for eye malignancy-related antineoplastic agents were retrieved from Taiwan's National Health Insurance Research Database (2009–2012). Main outcome measures We calculated the number of prescriptions and costs for each class of medications, and analysed their time trends. In addition, using a time series design with ARIMA models, we estimated the market share by prescription volume and the proportion of costs for targeted therapies for year 2016. Results The market share by prescription volume of targeted therapies grew from 1.56% in 2009 to 9.98% in 2012 among all antineoplastic agents, and the proportion of costs for targeted therapies rose from 15.12% in 2009 to 58.88% in 2012. Especially, the proportion of costs for protein kinase inhibitors grew from 25.62% to 45.28% among all antineoplastic agents between 2010 and 2012. The market share by prescription volume and the proportion of costs for targeted therapies for treatment of eye malignancies were predicted to reach 27.33% and 91.39% by the fourth quarter in 2016, respectively. Conclusions This is the first study that examined and forecasted use and costs of targeted therapies for treatment of eye malignancies in Taiwan. Our findings indicate that, compared with other classes of drugs, targeted therapies are having a more and more relevant share among all treatment strategies for eye malignancies in Taiwan, and due to their high costs they are likely to cause great economic burden. PMID:27235298

  15. The Eyes Have It: A Problem-Based Learning Exercise in Molecular Evolution

    ERIC Educational Resources Information Center

    White, Harold B.

    2007-01-01

    Molecular evolution provides an interesting context in which to use problem-based learning because it integrates a variety of topics in biology, biochemistry, and molecular biology. This three-stage problem for advanced students deals with the structure, multiple functions, and properties of lactate dehydrogenase isozymes, and the related…

  16. Conveying Clinical Reasoning Based on Visual Observation via Eye-Movement Modelling Examples

    ERIC Educational Resources Information Center

    Jarodzka, Halszka; Balslev, Thomas; Holmqvist, Kenneth; Nystrom, Marcus; Scheiter, Katharina; Gerjets, Peter; Eika, Berit

    2012-01-01

    Complex perceptual tasks, like clinical reasoning based on visual observations of patients, require not only conceptual knowledge about diagnostic classes but also the skills to visually search for symptoms and interpret these observations. However, medical education so far has focused very little on how visual observation skills can be…

  17. Eye Examination Findings Among Children. United States.

    ERIC Educational Resources Information Center

    Health Services and Mental Health Administration (DHEW), Bethesda, MD.

    Reported were extensive statistical data on the prevalence of abnormal eye conditions found on examination, heterophoria test results, and history of eye problems as well as extent of interrelationship of the eye examination and vision test findings among children aged 6 to 11 years in the United States, based on findings from the Health…

  18. Deficits in cue detection underlie event-based prospective memory impairment in major depression: an eye tracking study.

    PubMed

    Chen, Siyi; Zhou, Renlai; Cui, Hong; Chen, Xinyin

    2013-10-30

    This study examined the cue detection in the non-focal event-based prospective memory (PM) of individuals with and without a major depressive disorder using behavioural and eye tracking assessments. The participants were instructed to search on each trial for a different target stimulus that could be present or absent and to make prospective responses to the cue object. PM tasks included cue only and target plus cue, whereas ongoing tasks included target only and distracter only. The results showed that a) participants with depression performed more poorly than those without depression in PM; b) participants with depression showed more fixations and longer total and average fixation durations in both ongoing and PM conditions; c) participants with depression had lower scores on accuracy in target-plus-cue trials than in cue-only trials and had a higher gaze rate of targets on hits and misses in target-plus-cue trials than did those without depression. The results indicate that the state of depression may impair top-down cognitive control function, which in turn results in particular deficits in the engagement of monitoring for PM cues. PMID:23477903

  19. Drosophila MAGI interacts with RASSF8 to regulate E-Cadherin-based adherens junctions in the developing eye.

    PubMed

    Zaessinger, Sophie; Zhou, Yanxiang; Bray, Sarah J; Tapon, Nicolas; Djiane, Alexandre

    2015-03-15

    Morphogenesis is crucial during development to generate organs and tissues of the correct size and shape. During Drosophila late eye development, interommatidial cells (IOCs) rearrange to generate the highly organized pupal lattice, in which hexagonal ommatidial units pack tightly. This process involves the fine regulation of adherens junctions (AJs) and of adhesive E-Cadherin (E-Cad) complexes. Localized accumulation of Bazooka (Baz), the Drosophila PAR3 homolog, has emerged as a critical step to specify where new E-Cad complexes should be deposited during junction remodeling. However, the mechanisms controlling the correct localization of Baz are still only partly understood. We show here that Drosophila Magi, the sole fly homolog of the mammalian MAGI scaffolds, is an upstream regulator of E-Cad-based AJs during cell rearrangements, and that Magi mutant IOCs fail to reach their correct position. We uncover a direct physical interaction between Magi and the Ras association domain protein RASSF8 through a WW domain-PPxY motif binding, and show that apical Magi recruits the RASSF8-ASPP complex during AJ remodeling in IOCs. We further show that this Magi complex is required for the cortical recruitment of Baz and of the E-Cad-associated proteins α- and β-catenin. We propose that, by controlling the proper localization of Baz to remodeling junctions, Magi and the RASSF8-ASPP complex promote the recruitment or stabilization of E-Cad complexes at junction sites. PMID:25725070

  20. Synthesis and evaluation of simple naked-eye colorimetric chemosensors for anions based on azo dye-thiosemicarbazones

    NASA Astrophysics Data System (ADS)

    Radchatawedchakoon, Widchaya; Sangsuwan, Withsakorn; Kruanetr, Senee; Sakee, Uthai

    2014-03-01

    A series of novel, highly selective azo dye-thiosemicarbazones based anion sensors (3e-f) have been synthesized from the condensation reaction between thiosemicarbazide and six different azo salicylaldehydes. The structure of the sensors was confirmed by spectroscopic methods. The selectivity and sensitivity in the recognition for acetate anion over other anions such as fluoride, chloride, iodide and dihydrogenphosphate anions were determined by naked-eyes and UV-vis spectra. The color of the solution containing sensor had an obvious change from light yellow to orange only after the addition of acetate anion in aqueous solution (water/dimethylsulfoxide, 7:3, v/v) while other anions did not cause obvious color change. The anion recognition property of the receptor via proton-transfer is monitored by UV-vis titration and 1H NMR spectroscopy. Under condition in aqueous solution of sensor 3e (water/dimethylsulfoxide, 7:3, v/v), linearity range for the quantification of acetate anion was 1-22 μM and limit of detection (LOD) of acetate anion was 0.71 μM.

  1. Burn severity estimation using GeoEye imagery, object-based image analysis (OBIA), and Composite Burn Index (CBI) measurements

    NASA Astrophysics Data System (ADS)

    Dragozi, E.; Gitas, Ioannis Z.; Stavrakoudis, Dimitris G.; Minakou, C.

    2015-06-01

    Forest fires greatly influence the stability and functions of the forest ecosystems. The ever increasing need for accurate and detailed information regarding post-fire effects (burn severity) has led to several studies on the matter. In this study the combined use of Very High Resolution (VHR) satellite data (GeoEye), Objectbased image analysis (OBIA) and Composite Burn Index (CBI) measurements in estimating burn severity, at two different time points (2011 and 2012) is assessed. The accuracy of the produced maps was assessed and changes in burn severity between the two dates were detected using the post classification comparison approach. It was found that the produced burn severity map for 2011 was approximately 10% more accurate than that of 2012. This was mainly attributed to the increased heterogeneity of the study area in the second year, which led to an increased number of mixed class objects and consequently made it more difficult to spectrally discriminate between the severity classes. Following the post-classification analysis, the severity class changes were mainly attributed to the trees' ability to survive severe fire damage and sprout new leaves. Moreover, the results of the study suggest that when classifying CBI-based burn severity using VHR imagery it would be preferable to use images captured soon after the fire.

  2. Quantification of anthropogenic and natural changes in oil sands mining infrastructure land based on RapidEye and SPOT5

    NASA Astrophysics Data System (ADS)

    Zhang, Ying; Guindon, Bert; Lantz, Nicholas; Shipman, Todd; Chao, Dennis; Raymond, Don

    2014-06-01

    Natural resources development, spanning exploration, production and transportation activities, alters local land surface at various spatial scales. Quantification of these anthropogenic changes, both permanent and reversible, is needed for compliance assessment and for development of effective sustainable management strategies. Multi-spectral high resolution imagery data from SPOT5 and RapidEye were used for extraction and quantification of the anthropogenic and natural changes for a case study of Alberta bitumen (oil sands) mining located in the Western Boreal Plains near Fort McMurray, Canada. Two test sites representative of the major Alberta bitumen production extraction processes, open pit and in situ extraction, were selected. A hybrid change detection approach, combining pixel- and object-based target detection and extraction, is proposed based on Change Vector Analysis (CVA). The extraction results indicate that the changed infrastructure landscapes of these two sites have different footprints linked with their differing oil sands production processes. Pixel- and object-based accuracy assessments have been applied for validation of the change detection results. For manmade disturbances, except for those fine linear features such as the seismic lines, accuracies of about 80% have been achieved at the pixel level while, at the object level, these rise to 90-95%. Since many disturbance features are transient, a new landscape index, entitled the Re-growth Index, has been formulated at single object level specifically to monitor restoration of these features to their natural state. It is found that the temporal behaviour of the Re-growth Index in an individual patch varies depending on the type of natural land cover. In addition, the Re-growth Index is also useful for assessing the detectability of disturbed sites.

  3. Diabetes eye exams

    MedlinePlus

    ... catch problems early if you get regular eye exams. ... diabetes checks your eyes, you need an eye exam every 1 to 2 years by an eye ... problems with your vision. Many can do screening exams for damage from diabetes. Once you have eye ...

  4. Making a photomap of the human eye based on the spherical shape of its sclera and the circular contour of its iris

    NASA Astrophysics Data System (ADS)

    Ethrog, U.

    Iridology was defined as a method of diagnostic used in alternative medicine to analyze health status by studying colors, marks and signs in the sclera of the eye which according to iridologists can be demarcated into zones corresponding to parts of the human body. These are then made into "iridology charts" for comparison with photo images of a patient's eyes. Due to the large tilt angles of the images relative to the eye's geometrical axis, accurate comparison is not possible, and this paper suggests the use of photogrammetric methods for making a photomap for each of the patient's eyes which is then compared to its respective iridology chart. Because of the small overlapping area between any two successive images (about 20%) and the lack of control points, we were prevented from using conventional photogrammetric methods and instead had to develop an alternative photogrammetric method based on the spherical shape of the sclera and the circular shape of the iris contour. Accuracy tests showed that this method is relatively accurate and has small residuals following the process of bundle adjustment.

  5. Seeing through the dentist's eyes: video-based clinical demonstrations in preclinical dental training.

    PubMed

    Rystedt, Hans; Reit, Claes; Johansson, Elin; Lindwall, Oskar

    2013-12-01

    The clinical demonstration is an established way of bridging the disciplinary content in preclinical and clinical courses. In dentistry, however, clinical demonstrations have often been perceived as less rewarding due to the restricted visual access to the details of the treatment. This study investigated a course in endodontics at the University of Gothenburg, Sweden, in which traditional clinical demonstrations were replaced by instructor-led seminars that enabled students to follow and discuss broadcasted root canal treatments. Two cameras provided overviews of the operating room, whereas a third camera attached to a surgical microscope offered a magnified view of procedures carried out in the inner parts of teeth. The hypothesis was that this arrangement would increase the students' sense of the clinical relevance of basic scientific knowledge. Two focus group interviews were designed to explore the students' perceptions of this change. The students expressed that the video-based seminars offered ample opportunities to integrate theoretical and clinical understanding. The major reasons were that the visualization displayed procedures on a sufficiently detailed level; instructors demonstrated clinical reasoning in situ and provided the context necessary for understanding procedures; and the interactive format encouraged discussions on the generalizability of knowledge beyond the specific case. PMID:24319135

  6. Eye-gaze independent EEG-based brain-computer interfaces for communication.

    PubMed

    Riccio, A; Mattia, D; Simione, L; Olivetti, M; Cincotti, F

    2012-08-01

    The present review systematically examines the literature reporting gaze independent interaction modalities in non-invasive brain-computer interfaces (BCIs) for communication. BCIs measure signals related to specific brain activity and translate them into device control signals. This technology can be used to provide users with severe motor disability (e.g. late stage amyotrophic lateral sclerosis (ALS); acquired brain injury) with an assistive device that does not rely on muscular contraction. Most of the studies on BCIs explored mental tasks and paradigms using visual modality. Considering that in ALS patients the oculomotor control can deteriorate and also other potential users could have impaired visual function, tactile and auditory modalities have been investigated over the past years to seek alternative BCI systems which are independent from vision. In addition, various attentional mechanisms, such as covert attention and feature-directed attention, have been investigated to develop gaze independent visual-based BCI paradigms. Three areas of research were considered in the present review: (i) auditory BCIs, (ii) tactile BCIs and (iii) independent visual BCIs. Out of a total of 130 search results, 34 articles were selected on the basis of pre-defined exclusion criteria. Thirteen articles dealt with independent visual BCIs, 15 reported on auditory BCIs and the last six on tactile BCIs, respectively. From the review of the available literature, it can be concluded that a crucial point is represented by the trade-off between BCI systems/paradigms with high accuracy and speed, but highly demanding in terms of attention and memory load, and systems requiring lower cognitive effort but with a limited amount of communicable information. These issues should be considered as priorities to be explored in future studies to meet users' requirements in a real-life scenario. PMID:22831893

  7. Eye-gaze independent EEG-based brain-computer interfaces for communication

    NASA Astrophysics Data System (ADS)

    Riccio, A.; Mattia, D.; Simione, L.; Olivetti, M.; Cincotti, F.

    2012-08-01

    The present review systematically examines the literature reporting gaze independent interaction modalities in non-invasive brain-computer interfaces (BCIs) for communication. BCIs measure signals related to specific brain activity and translate them into device control signals. This technology can be used to provide users with severe motor disability (e.g. late stage amyotrophic lateral sclerosis (ALS); acquired brain injury) with an assistive device that does not rely on muscular contraction. Most of the studies on BCIs explored mental tasks and paradigms using visual modality. Considering that in ALS patients the oculomotor control can deteriorate and also other potential users could have impaired visual function, tactile and auditory modalities have been investigated over the past years to seek alternative BCI systems which are independent from vision. In addition, various attentional mechanisms, such as covert attention and feature-directed attention, have been investigated to develop gaze independent visual-based BCI paradigms. Three areas of research were considered in the present review: (i) auditory BCIs, (ii) tactile BCIs and (iii) independent visual BCIs. Out of a total of 130 search results, 34 articles were selected on the basis of pre-defined exclusion criteria. Thirteen articles dealt with independent visual BCIs, 15 reported on auditory BCIs and the last six on tactile BCIs, respectively. From the review of the available literature, it can be concluded that a crucial point is represented by the trade-off between BCI systems/paradigms with high accuracy and speed, but highly demanding in terms of attention and memory load, and systems requiring lower cognitive effort but with a limited amount of communicable information. These issues should be considered as priorities to be explored in future studies to meet users’ requirements in a real-life scenario.

  8. Validation of a paleo river system derived by ground based electromagnetic induction measurements with satellite based RapidEye images

    NASA Astrophysics Data System (ADS)

    Rudolph, Sebastian; von Hebel, Christian; Ali, Mohammed; Stadler, Anja; Herbst, Michael; Montzka, Carsten; Pätzold, Stefan; Weihermüller, Lutz; van der Kruk, Jan; Vereecken, Harry

    2013-04-01

    Morphological remnants of an inactive river system that has been filled by younger sediments can provide datable proxies about past climatic conditions. However, sediment composition of their infillings is a challenge for agriculture, in particular for precision agriculture. Differential crop development and yield reduction are often a consequence of lateral and vertical textural inhomogeneities. Several studies have shown that buried river systems can be traced by the use of remote sensing. However, the appearance of crop marks strongly depends on environmental conditions, and therefore, the reliance of remotely acquired data can become time and cost expensive. Soil physical properties which are related to textural differences can be mapped fast and cost-effective by the use of near surface geophysics. Especially electromagnetic induction (EMI), which measures soil apparent conductivity (ECa), has become a tool of choice to characterize large areas in high resolution. The introduction of multiple coil EMI systems as well as the quantification of respective measurements enables a reliable multilayer inversion. The aim of this study was to map a postglacial river system on agricultural fields and to mark out buried remains such as trenches and bomb craters of World War II. In summer 2012 ten fields (17 ha) were mapped with the CMD MiniExplorer, a multiple coil EMI system especially appropriate for near surface applications, after the harvest of winter wheat and sugar beet. At elevated sandy sites meander like patterns with higher conductivity were mapped. ECa measurements were verified by textural data taken from directed soil samples and vertical ECa logs. Sediment thickness was evaluated on soil cores and electrical resistivity tomography (ERT) transects. Furthermore, ERT quantified ECa measurements were correlated with satellite as well as destructive derived leaf area index (LAI) measurements. In 3 of 71 LAI maps derived by multispectral RapidEye imagery crop

  9. Numerical study on statistical properties of speckle pattern in laser projection display based on human eye model

    NASA Astrophysics Data System (ADS)

    Cui, Zhe; Wang, Anting; Ma, Qianli; Ming, Hai

    2013-12-01

    In this paper, the laser speckle pattern on human retina for a laser projection display is simulated. By introducing a specific eye model `Indiana Eye', the statistical properties of the laser speckle are numerical investigated. The results show that the aberrations of human eye (mostly spherical and chromatic) will decrease the speckle contrast felt by people. When the wavelength of the laser source is 550 nm (green), people will feel the strongest speck pattern and the weakest when the wavelength is 450 nm (blue). Myopia and hyperopia will decrease the speckle contrast by introducing large spherical aberrations. Although aberration is good for speckle reduction, but it will degrade the imaging capability of the eye. The results show that laser source (650 nm) will have the best image quality on the retina. At last, we compare the human eye with an aberration-free imaging system. Both the speckle contrast and the image quality appear different behavior in these two imaging systems. The results are useful when a standardized measurement procedure for speckle contrast needs to be built.

  10. Eye muscle repair - discharge

    MedlinePlus

    ... page: //medlineplus.gov/ency/patientinstructions/000111.htm Eye muscle repair - discharge To use the sharing features on ... enable JavaScript. You or your child had eye muscle repair surgery to correct eye muscle problems that ...

  11. Eye muscle repair - slideshow

    MedlinePlus

    ... page: //medlineplus.gov/ency/presentations/100062.htm Eye muscle repair - series—Normal anatomy To use the sharing ... the eyeball to the eye socket. The external muscles of the eye are found behind the conjunctiva. ...

  12. Dilating Eye Drops

    MedlinePlus

    ... Frequently Asked Questions Español Condiciones Chinese Conditions Dilating Eye Drops En Español Read in Chinese What are dilating eye drops? Dilating eye drops contain medication to enlarge ( ...

  13. Fluorescent eye test (image)

    MedlinePlus

    The fluorescent eye test is useful in determining if there is a scratch or other problem with the surface ... has thoroughly covered the eye a cobalt blue light is then directed on the eye. The light ...

  14. Evaluating Experience-Based Geologic Field Instruction: Lessons Learned from A Large-Scale Eye-Tracking Experiment

    NASA Astrophysics Data System (ADS)

    Tarduno, J. A.; Walders, K.; Bono, R. K.; Pelz, J.; Jacobs, R.

    2015-12-01

    A course centered on experience-based learning in field geology has been offered ten times at the University of Rochester. The centerpiece of the course is a 10-day field excursion to California featuring a broad cross-section of the geology of the state, from the San Andreas Fault to Death Valley. Here we describe results from a large-scale eye-tracking experiment aimed at understanding how experts and novices acquire visual geologic information. One ultimate goal of the project is to determine whether expert gaze patterns can be quantified to improve the instruction of beginning geology students. Another goal is to determine if aspects of the field experience can be transferred to the classroom/laboratory. Accordingly, ultra-high resolution segmented panoramic images have been collected at key sites visited during the field excursion. We have found that strict controls are needed in the field to obtain meaningful data; this often involves behavior atypical of geologists (e.g. limiting the field of view prior to data collection and placing time limits on scene viewing). Nevertheless some general conclusions can be made from a select data set. After an initial quick search, experts tend to exhibit scanning behavior that appears to support hypothesis testing. Novice fixations appear to define a scattered search pattern and/or one distracted by geologic noise in a scene. Noise sources include modern erosion features and vegetation. One way to quantify noise is through the use of saliency maps. With the caveat that our expert data set is small, our preliminary analysis suggests that experts tend to exhibit top-down behavior (indicating hypothesis driven responses) whereas novices show bottom-up gaze patterns, influenced by more salient features in a scene. We will present examples and discuss how these observations might be used to improve instruction.

  15. Eyeing Ganymede

    NASA Technical Reports Server (NTRS)

    2000-01-01

    Jupiter casts a baleful eye toward the moon Ganymede in this enhanced-contrast image from NASA's Cassini spacecraft.

    Jupiter's 'eye', the Great Red Spot, was captured just before disappearing around the eastern edge of the planet. The furrowed eyebrow above and to the left of the spot is a turbulent wake region caused by westward flow that has been deflected to the north and around the Red Spot. The smallest features visible are about 240 kilometers (150 miles) across.

    Within the band south of the Red Spot are a trio of white ovals, high pressure counterclockwise-rotating regions that are dynamically similar to the Red Spot. The dark filamentary features interspersed between white ovals are probably cyclonic circulations and, unlike the ovals, are rotating clockwise.

    Jupiter's equatorial zone stretching across the planet north of the Spot appears bright white, with gigantic plume clouds spreading out from the equator both to the northeast and to the southeast in a chevron pattern. This zone looks distinctly different than it did during the Voyager flyby 21 years ago. Then, its color was predominantly brown and the only white plumes conspicuous against the darker material beneath them were oriented southwest-to-northeast.

    Ganymede is Jupiter's largest moon, about 50 percent larger than our own Moon and larger than the planet Mercury. The visible details in this image are different geological terrains. Dark areas tend to be older and heavily cratered; brighter areas are younger and less cratered. Cassini images of Ganymede and Jupiter's other large moons taken near closest approach on Dec. 30 will have resolutions about four times better than that seen here.

    This image is a color composite of ones taken with different filters by Cassini's narrow-angle camera on Nov. 18, 2000, processed to enhance contrast. Cassini is a cooperative project of NASA, the European Space Agency and the Italian Space Agency. The Jet Propulsion Laboratory, a division of

  16. Prediction of eye irritation potential of surfactant-based rinse-off personal care formulations by the bovine corneal opacity and permeability (BCOP) assay.

    PubMed

    Cater, Kathleen C; Harbell, John W

    2006-01-01

    Evaluation of eye irritation potential is a routine part of product safety testing. Many companies have elected to use in vitro methods for this evaluation. We used the bovine corneal opacity and permeability (BCOP) assay for the prediction of the eye irritation potential of surfactant-based rinse-off personal care formulations in this study because of its positive performance in previous studies (1), and its potential to measure depth of injury through histological evaluation. The BCOP uses isolated corneas maintained in short-term organ culture and measures changes in opacity and epithelial barrier integrity (as determined by fluorescein passage through the cornea). Surfactants (anionic and nonionic) used in personal care formulations induce only small increases in direct opacity but the degree of epithelial damage is reflected in permeability measurement (OD490). The permeability measurement is the primary endpoint for this class of products. Marketed liquid hand soap was selected as the benchmark due to extensive in vivo and market history data. Using the liquid hand soap, a 25% v/v aqueous dilution with a 30-minute exposure produced the optimal resolution. A series of products with known in vivo eye irritation scores were evaluated to establish a prediction model. Histological evaluation was used to compare the degree of tissue damage to the permeability scores. Based on the permeability scores and histological review, the testing protocol for a surfactant-based rinse-off personal care formulation was developed using a 25% v/v aqueous dilution, a 30-minute exposure, concurrent testing of the benchmark control, and use of permeability measurements as the endpoint for the evaluation of eye irritation potential. PMID:16980247

  17. A software module for implementing auditory and visual feedback on a video-based eye tracking system

    NASA Astrophysics Data System (ADS)

    Rosanlall, Bharat; Gertner, Izidor; Geri, George A.; Arrington, Karl F.

    2016-05-01

    We describe here the design and implementation of a software module that provides both auditory and visual feedback of the eye position measured by a commercially available eye tracking system. The present audio-visual feedback module (AVFM) serves as an extension to the Arrington Research ViewPoint EyeTracker, but it can be easily modified for use with other similar systems. Two modes of audio feedback and one mode of visual feedback are provided in reference to a circular area-of-interest (AOI). Auditory feedback can be either a click tone emitted when the user's gaze point enters or leaves the AOI, or a sinusoidal waveform with frequency inversely proportional to the distance from the gaze point to the center of the AOI. Visual feedback is in the form of a small circular light patch that is presented whenever the gaze-point is within the AOI. The AVFM processes data that are sent to a dynamic-link library by the EyeTracker. The AVFM's multithreaded implementation also allows real-time data collection (1 kHz sampling rate) and graphics processing that allow display of the current/past gaze-points as well as the AOI. The feedback provided by the AVFM described here has applications in military target acquisition and personnel training, as well as in visual experimentation, clinical research, marketing research, and sports training.

  18. Wave optics analysis of corner-cube retro-reflectors in near-to-eye displays based on scanning laser projectors

    NASA Astrophysics Data System (ADS)

    Kazempourradi, Seyedmahdi; Ulusoy, Erdem; Holmstrom, Sven; Urey, Hakan

    2015-09-01

    In near to eye displays based on scanning laser projectors, retro-reflectors seem as convenient image relay components since they can ideally be placed at any location on the scanned beam path. In case of practical retro reflectors though, such as corner cube retro-reflectors (CCRs), the relayed image suffers from loss in quality and resolution due to the positional shift in the retro-reflected rays and the diffraction effects. We perform a wave optics simulation to analyze the image relay performance of a CCR. Our model assumes that the scanned spot of the projector is imaged by the CCR into an array of spots, which superpose and interfere to yield the effective scan spot seen by an eye looking at the CCR. The results indicate that the CCR results in a significant broadened spot size. Experimental results verify the simulation model in terms of achievable resolution and image quality.

  19. Grader agreement, and sensitivity and specificity of digital photography in a community optometry-based diabetic eye screening program

    PubMed Central

    Sellahewa, Luckni; Simpson, Craig; Maharajan, Prema; Duffy, John; Idris, Iskandar

    2014-01-01

    Background Digital retinal photography with mydriasis is the preferred modality for diabetes eye screening. The purpose of this study was to evaluate agreement in grading levels between primary and secondary graders and to calculate their sensitivity and specificity for identifying sight-threatening disease in an optometry-based retinopathy screening program. Methods This was a retrospective study using data from 8,977 patients registered in the North Nottinghamshire retinal screening program. In all cases, the ophthalmology diagnosis was used as the arbitrator and considered to be the gold standard. Kappa statistics were used to evaluate the level of agreement between graders. Results Agreement between primary and secondary graders was 51.4% and 79.7% for detecting no retinopathy (R0) and background retinopathy (R1), respectively. For preproliferative (R2) and proliferative retinopathy (R3) at primary grading, agreement between the primary and secondary grader was 100%. Where there was disagreement between the primary and secondary grader for R1, only 2.6% (n=41) were upgraded by an ophthalmologist. The sensitivity and specificity for detecting R3 was 78.2% and 98.1%, respectively. None of the patients upgraded from any level of retinopathy to R3 required photocoagulation therapy. The observed kappa between the primary and secondary grader was 0.3223 (95% confidence interval 0.2937–0.3509), ie, fair agreement, and between the primary grader and ophthalmology for R3 was 0.5667 (95% confidence interval 0.4557–0.6123), ie, moderate agreement. Conclusion These data provide information on the safety of a community optometry-based retinal screening program for screening as a primary and as a secondary grader. The level of agreement between the primary and secondary grader at a higher level of retinopathy (R2 and R3) was 100%. Sensitivity and specificity for R3 were 78.2% and 98.1%, respectively. None of the false-negative results required photocoagulation therapy

  20. Eye muscle repair - series (image)

    MedlinePlus

    ... the eyeball to the eye socket. The external muscles of the eye are found behind the conjunctiva. ... The extraocular muscles of the eye (external to the eyeball) control the positioning of the eyes. They coordinate of the eye ...

  1. Eating for Your Eyes

    ERIC Educational Resources Information Center

    Stastny, Sherri Nordstrom; Garden-Robinson, Julie

    2011-01-01

    An educational program targeting older adults was developed to increase knowledge regarding nutrition and eye health. With age, the chance for eye disease increases, so prevention is critical. The Eating for Your Eyes program has promoted behavior changes regarding eye health among the participants. This program is easily replicated and use is…

  2. Eye Injury Prevention for the Pediatric Population.

    PubMed

    Hoskin, Annette K; Philip, Swetha S; Yardley, Anne-Marie E; Mackey, David A

    2016-05-01

    Each year an estimated 3.3 to 5.7 million pediatric eye injuries occur worldwide. It is widely reported that 90% of ocular injuries are preventable. Our aim was to identify legislation and policies, education, and mandatory eye protection strategies that have successfully contributed to reducing rates of children's eye injuries. A literature search was conducted using the terms "pediatric" or "children" or "adolescent" and "ocular" or "eye" and "protection" or "injury prevention." Articles were retrieved based on titles and abstracts and assessed in the context of our research question. Strategies identified aimed at reducing ocular trauma fell into 3 broad categories: legislation and policies, education, and personal eye protection. Policies including restrictions on the sale and supply of certain consumer products, mandatory vehicle seatbelts, and laminated windscreens in vehicles have assisted in reducing children's eye injuries. Educational tools aimed at children and their caregivers have been effective in changing attitudes to eye health and safety. Effective pediatric eye injury prevention systems require a multifactorial approach combining legislation, policies, standards, education, and personal eye protection to limit exposure to ocular hazards. A paucity of standardized measurement and lack of funding have limited advances in the field of children's eye injury prevention. Improved eye injury surveillance and research funding along with collaboration with health care providers are important components for strategies to prevent pediatric ocular trauma. PMID:27183290

  3. Choroidal vascularity index as a measure of vascular status of the choroid: Measurements in healthy eyes from a population-based study

    NASA Astrophysics Data System (ADS)

    Agrawal, Rupesh; Gupta, Preeti; Tan, Kara-Anne; Cheung, Chui Ming Gemmy; Wong, Tien-Yin; Cheng, Ching-Yu

    2016-02-01

    The vascularity of the choroid has been implicated in the pathogenesis of various eye diseases. To date, no established quantifiable parameters to estimate vascular status of the choroid exists. Choroidal vascularity index (CVI) may potentially be used to assess vascular status of the choroid. We aimed to establish normative database for CVI and identify factors associated with CVI in healthy eyes. In this population-based study on 345 healthy eyes, choroidal enhanced depth imaging optical coherence tomography scans were segmented by modified image binarization technique. Total subfoveal choroidal area (TCA) was segmented into luminal (LA) and stromal (SA) area. CVI was calculated as the proportion of LA to TCA. Linear regression was used to identify ocular and systemic factors associated with CVI and subfoveal choroidal thickness (SFCT). Subfoveal CVI ranged from 60.07 to 71.27% with a mean value of 65.61 ± 2.33%. CVI was less variable than SFCT (coefficient of variation for CVI was 3.55 vs 40.30 for SFCT). Higher CVI was associated with thicker SFCT, but not associated with most physiological variables. CVI was elucidated as a significant determinant of SFCT. While SFCT was affected by many factors, CVI remained unaffected suggesting CVI to be a more robust marker of choroidal diseases.

  4. Choroidal vascularity index as a measure of vascular status of the choroid: Measurements in healthy eyes from a population-based study

    PubMed Central

    Agrawal, Rupesh; Gupta, Preeti; Tan, Kara-Anne; Cheung, Chui Ming Gemmy; Wong, Tien-Yin; Cheng, Ching-Yu

    2016-01-01

    The vascularity of the choroid has been implicated in the pathogenesis of various eye diseases. To date, no established quantifiable parameters to estimate vascular status of the choroid exists. Choroidal vascularity index (CVI) may potentially be used to assess vascular status of the choroid. We aimed to establish normative database for CVI and identify factors associated with CVI in healthy eyes. In this population-based study on 345 healthy eyes, choroidal enhanced depth imaging optical coherence tomography scans were segmented by modified image binarization technique. Total subfoveal choroidal area (TCA) was segmented into luminal (LA) and stromal (SA) area. CVI was calculated as the proportion of LA to TCA. Linear regression was used to identify ocular and systemic factors associated with CVI and subfoveal choroidal thickness (SFCT). Subfoveal CVI ranged from 60.07 to 71.27% with a mean value of 65.61 ± 2.33%. CVI was less variable than SFCT (coefficient of variation for CVI was 3.55 vs 40.30 for SFCT). Higher CVI was associated with thicker SFCT, but not associated with most physiological variables. CVI was elucidated as a significant determinant of SFCT. While SFCT was affected by many factors, CVI remained unaffected suggesting CVI to be a more robust marker of choroidal diseases. PMID:26868048

  5. Novel automatic eye detection and tracking algorithm

    NASA Astrophysics Data System (ADS)

    Ghazali, Kamarul Hawari; Jadin, Mohd Shawal; Jie, Ma; Xiao, Rui

    2015-04-01

    The eye is not only one of the most complex but also the most important sensory organ of the human body. Eye detection and eye tracking are basement and hot issue in image processing. A non-invasive eye location and eye tracking is promising for hands-off gaze-based human-computer interface, fatigue detection, instrument control by paraplegic patients and so on. For this purpose, an innovation work frame is proposed to detect and tracking eye in video sequence in this paper. The contributions of this work can be divided into two parts. The first contribution is that eye filters were trained which can detect eye location efficiently and accurately without constraints on the background and skin colour. The second contribution is that a framework of tracker based on sparse representation and LK optic tracker were built which can track eye without constraint on eye status. The experimental results demonstrate the accuracy aspects and the real-time applicability of the proposed approach.

  6. Factors Associated with Awareness, Attitudes and Practices Regarding Common Eye Diseases in the General Population in a Rural District in Bangladesh: The Bangladesh Population-based Diabetes and Eye Study (BPDES)

    PubMed Central

    Islam, Fakir M. Amirul; Chakrabarti, Rahul; Islam, Silvia Z.; Finger, Robert P.; Critchley, Christine

    2015-01-01

    Background To assess the awareness, attitudes, and practices associated with common eye diseases and eye care utilization in a rural district of Bangladesh. Methods Data were collected using a multilevel cluster random sampling technique from 3104 adults aged ≥30 years from the Banshgram union with a questionnaire assessing the awareness, attitudes and practice about diabetes and common eye diseases, educational attainment, socio-economic status, and medical history. Results Participants were aged between 30 and 89 years with a mean (SD) age of 51 (12) years and 65% were female. The majority of participants had heard of cataracts (90%), trachoma (86%) and Pterygium (84%), yet only 4% had heard of diabetic retinopathy (DR), 7% of glaucoma and 8% of Age-related macular degeneration (AMD). However, 58% of participants did not know vision loss could be prevented. Factors associated with lower awareness regarding common eye diseases were increasing age, lack of formal schooling, and lower socio-economic status. A lower proportion (57%) of people with no schooling compared to those who had attained at least secondary school certificate education (72%) reported that they knew that vision loss could be prevented (p<0.001). Overall 51% of people had heard of at least six (67%) out of nine items relating to awareness of common eye diseases. This included 41% of participants aged 65 years or older compared to 61% of those aged 30–35 years (p<0.001). Only 4% had an eye check at least once a year and higher education and better SES were associated with higher frequency of eye checks. Conclusions In rural Bangladesh awareness of cataract, trachoma and pterygium was good but limited in relation to the potentially blinding conditions of glaucoma, DR, and AMD. The results show a large gap between public awareness and treatment practices about common eye diseases. Public health promotion should be designed to address these knowledge gaps. PMID:26200458

  7. Considerations concerning the basic bandwidth reduction of high definition television systems (HDTV) component signals, based on psychophysiological properties of the eye

    NASA Astrophysics Data System (ADS)

    Holoch, G.

    1987-03-01

    Psychophysiological properties of human vision are described, with a view to a reduction of irrelevant signal components in the transmission of TV component signals. The space-time frequency response of human vision, and the sensitivity of the eye to diagonal structures, peripheral vision, and luminosity graduation are discussed. Based on these characteristics, scanning and filtering methods are proposed. It is shown that a compression of the bandwidth to 4.6 MHz is possible provided a spatial resolution of 14 periods/deg for the brilliance signal (18 MHz) is realized using diagonal filtering, offset scanning, and vertical subscanning.

  8. Lens of Eye Dosimetry

    SciTech Connect

    Mallett, Michael Wesley

    2015-03-23

    An analysis of LANL occupational dose measurements was made with respect to lens of eye dose (LOE), in particular, for plutonium workers. Table 1 shows the reported LOE as a ratio of the “deep” (photon only) and “deep+neutron” dose for routine monitored workers at LANL for the past ten years. The data compares the mean and range of these values for plutonium workers* and non-routine plutonium workers. All doses were reported based on measurements with the LANL Model 8823 TLD.

  9. Lasik eye surgery - discharge

    MedlinePlus

    ... page: //medlineplus.gov/ency/patientinstructions/000525.htm Lasik eye surgery - discharge To use the sharing features on this page, please enable JavaScript. Lasik eye surgery permanently changes the shape of the cornea ( ...

  10. Diabetic Eye Problems

    MedlinePlus

    ... too high. Over time, this can damage your eyes. The most common problem is diabetic retinopathy. It ... light-sensitive tissue at the back of your eye. You need a healthy retina to see clearly. ...

  11. Fluorescein eye stain

    MedlinePlus

    Abnormal results may point to: Abnormal tear production (dry eye) Blocked tear duct Corneal abrasion (a scratch on ... foreign object in ) Infection Injury or trauma Severe dry eye associated with arthritis (keratoconjunctivitis sicca)

  12. Eye Injuries at Work

    MedlinePlus

    ... Bureau of Labor Statistics, more than 20,000 workplace eye injuries happen each year. Injuries on the job often ... Occupational Safety and Health Administration (OSHA) reports that workplace eye injuries cost an estimated $300 million a year in ...

  13. Eye Injuries (For Parents)

    MedlinePlus

    ... eye nausea or vomiting after an eye injury Think Prevention! Kids who play sports should wear protective goggles or unbreakable glasses as needed. Keep chemicals and other potentially dangerous objects out of the reach of children. Reviewed by: ...

  14. Diabetic Eye Problems

    MedlinePlus

    ... this can damage your eyes. The most common problem is diabetic retinopathy. It is a leading cause ... surgery, with follow-up care. Two other eye problems can happen to people with diabetes. A cataract ...

  15. Eye muscle repair

    MedlinePlus

    ... Your child's eyes should look normal a few weeks after the surgery. ... Surgical Approach to the Rectus Muscles. In: Tasman W, Jaeger EA, ... Hug D, Plummer LS, Stass-Isern M. Disorders of eye movement and ...

  16. Anatomy of the Eye

    MedlinePlus

    ... Examinations, Adults Patient Eye Examinations, Children Refractive Errors Scientists in the Laboratory Visual Acuity Testing Anatomy of the Eye × Warning message Automatic fallback to the cURL connection method kicked in to handle the request. Result code ...

  17. Patient Eye Examinations - Adults

    MedlinePlus

    ... Examinations, Adults Patient Eye Examinations, Children Refractive Errors Scientists in the Laboratory Visual Acuity Testing Patient Eye Examinations, Adults × Warning message Automatic fallback to the cURL connection method kicked in to handle the request. Result code ...

  18. Eye muscle repair

    MedlinePlus

    ... and physical exam before the procedure Orthoptic measurements (eye movement measurements) Always tell your child's doctor or nurse: ... D, Plummer LS, Stass-Isern M. Disorders of eye movement and alignment. In: Kliegman RM, Behrman RE, Jenson ...

  19. Eye Injuries (For Parents)

    MedlinePlus

    ... and comfortable as possible until help arrives. continue Chemical Exposure Many chemicals, even those found around the house, can damage an eye. If your child gets a chemical in the eye and you know what it ...

  20. Diabetes - eye care

    MedlinePlus

    ... dilated eye exam. This is called digital retinal photography. Your eye doctor may ask you to come ... doctor if: You cannot see well in dim light. You have blind spots. You have double vision ( ...

  1. Diabetes and eye disease

    MedlinePlus

    ... the eye that can lead to blindness Macular edema: blurry vision due to fluid leaking into the ... in your retina (neovascularization) or you develop macular edema, treatment is usually needed. Eye surgery is the ...

  2. Eye and orbit ultrasound

    MedlinePlus

    ... the eye (vitreous hemorrhage) Cancer of the retina ( retinoblastoma ), under the retina, or in other parts of ... Cataract removal Melanoma of the eye Retinal detachment Retinoblastoma Ultrasound Update Date 2/23/2015 Updated by: ...

  3. Down Syndrome: Eye Problems

    MedlinePlus

    ... life expectancy. Do children with Down syndrome have eye problems? Individuals with Down syndrome are at increased ... When should children with Down syndrome receive an eye exam? The American Academy of Pediatrics recommends that ...

  4. Toxoplasmosis (and the Eye)

    MedlinePlus

    ... of known infected babies. What happens to the eyes of babies born with congenital toxoplasmosis? The infection ... to further reduce the inflammation. Updated 03/2015 Eye Terms & Conditions Most Common Searches Adult Strabismus Amblyopia ...

  5. Sports and Your Eyes

    MedlinePlus

    ... Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and Safety First Aid Tips Healthy Vision ... More Information Optical Illusions Printables Sports and Your Eyes Gear up! If you play sports, you know ...

  6. Diabetes eye exams

    MedlinePlus

    ... are near. Sunlight can damage your eye. Wear dark glasses or shade your eyes until the effects ... to the principles of the Health on the Net Foundation (www.hon.ch). The information provided herein ...

  7. Anatomy of the Eye

    MedlinePlus

    ... it becomes red or pink. This is called conjunctivitis or “pinkeye”. Lacrimal Gland: The lacrimal gland produces tears that ... Conditions Most Common Searches Adult Strabismus Amblyopia Cataract Conjunctivitis Corneal Abrasions Dilating Eye Drops Lazy eye (defined) ...

  8. Eye - foreign object in

    MedlinePlus

    ... medlineplus.gov/ency/article/002084.htm Eye - foreign object in To use the sharing features on this ... Blinking The eye will often flush out small objects, like eyelashes and sand, through blinking and tearing. ...

  9. Shack–Hartmann-based objective straylight assessment of the human eye in an increased scattering angle range

    NASA Astrophysics Data System (ADS)

    Schramm, Stefan; Schikowski, Patrick; Lerm, Elena; Kaeding, André; Haueisen, Jens; Baumgarten, Daniel

    2016-07-01

    Objective measurement of straylight in the human eye with a Shack-Hartmann (SH) wavefront aberrometer is limited in imaging angle. We propose a measurement principle and a point spread function (PSF) reconstruction algorithm to overcome this limitation. In our optical setup, a variable stop replaces the stop conventionally used to suppress reflections and scatter in SH aberrometers. We record images with 21 diameters of the stop. From each SH image, the average intensity of the pupil is computed and normalized. The intensities represent integral values of the PSF. We reconstruct the PSF, which is the derivative of the intensities with respect to the visual angle. A modified Stiles Holladay approximation is fitted to the reconstructed PSF, resulting in a straylight parameter. A proof-of-principle study was carried out on eight healthy young volunteers. Scatter filters were positioned in front of the volunteers' eyes to simulate straylight. The straylight parameter was compared to the C-Quant measurements and the filter values. The PSF parameter shows strong correlation with the density of the filters and a linear relation to the C-Quant straylight parameter. Our measurement and reconstruction techniques allow for objective straylight analysis of visual angles up to 4 deg.

  10. Protective area of laser eye protectors

    NASA Astrophysics Data System (ADS)

    Sutter, E.; Schirmacher, A.

    2001-06-01

    An objective definition of the protective area of laser eye protectors is discussed. First an appropriate test method is described, which is based on the current eye protection standard EN 168. For a variety of already CE type approved laser eye protectors, i.e. for different goggle and spectacle types, results of corresponding measurements are shown. From these results the requirements on the vertical and horizontal angle ranges are derived, which have to be covered by laser eye protectors. This proposal will be implemented in the currently processed amendments of the laser safety standards EN 207 and EN 208.

  11. Automatic emotional expression analysis from eye area

    NASA Astrophysics Data System (ADS)

    Akkoç, Betül; Arslan, Ahmet

    2015-02-01

    Eyes play an important role in expressing emotions in nonverbal communication. In the present study, emotional expression classification was performed based on the features that were automatically extracted from the eye area. Fırst, the face area and the eye area were automatically extracted from the captured image. Afterwards, the parameters to be used for the analysis through discrete wavelet transformation were obtained from the eye area. Using these parameters, emotional expression analysis was performed through artificial intelligence techniques. As the result of the experimental studies, 6 universal emotions consisting of expressions of happiness, sadness, surprise, disgust, anger and fear were classified at a success rate of 84% using artificial neural networks.

  12. Get Your Eyes Tested

    MedlinePlus

    ... over age 40 Have a family history of glaucoma Have diabetes People with diabetes may need eye exams more ... or if you have a family member with diabetes or an eye disease. Eye diseases like glaucoma can lead to vision loss and blindness if ...

  13. Dwarf Eye Disorder

    ERIC Educational Resources Information Center

    Science Teacher, 2005

    2005-01-01

    Johns Hopkins researchers at the Wilmer Eye Institute have discovered what appears to be the first human gene mutation that causes extreme farsightedness. The researchers report that nanophthalmos, Greek for "dwarf eye," is a rare, potentially blinding disorder caused by an alteration in a gene called MFRP that helps control eye growth and…

  14. Calibration of an eye oximeter with a dynamic eye phantom

    NASA Astrophysics Data System (ADS)

    Nabili, A.; Bardakci, D.; Helling, K.; Matyas, C.; Muro, S.; Ramella-Roman, J. C.

    2008-02-01

    Measurements of oxygen saturation and flow in the retina can yield information about the eye health and the onset of eye pathologies such as Diabetic Retinopathy. Recently we have realized an instrument capable of measuring oxygenation in the retina using six different wavelengths and capable of measuring blood flow using speckle-based techniques. The calibration of such instrument is particularly difficult due to the layered structure of the eye and the lack of alternative measurement techniques. For this purpose we have realized an in vitro model of the human eye. The artificial eye is composed of four layers: the retina vessels, the choroids, the retinal pigmented epithelium (RPE), and the sclera. The retina vessels are modeled with 150 μm tube connected to a micro-pump delivering 34 μl/min. The micro-tube, the pump, and a blood reservoir were connected in a closed circulatory system; blood oxygenation in the vessel could be modified using an external oxygen reservoir. The optical properties of all other layers were mimicked using titanium dioxide as a scatterer and ink as an absorber. The absorption coefficient μa and the scattering coefficient µs of these layers were independently measured using an integrating sphere. Absorption and scattering coefficient of all layers were modified before experimental measurements and a Monte Carlo program was finally used to model the experimental results.

  15. Exploitation of GeoEye-1 Data for Land Use/Land Cover Analysis Using Object-Based Image Analysis in the Eastern Nile Basin of Sudan

    NASA Astrophysics Data System (ADS)

    Guma Biro Turk, Khalid; Pradhan, Biswajeet

    Recently, object-oriented classification techniques based on image segmentation approaches are being studied using high-resolution satellite images to extract various thematic information. In this study different types of land use/land cover (LULC) types were analysed by employing object-based image analysis approach to GeoEye-1 data at the Eastern Nile Basin of Sudan. For that purpose, multi-resolution segmentation (MRS) of the Definiens software was used for creating the image objects. Using the feature space optimisation (FSO) tool the attributes of the GeoEye-1 image were optimised in order to obtain the best separability among classes for the LULC mapping. The best separation distance of the tested spectral, shape and textural features showed different variations among the discriminated LULC classes. An overall accuracy of 94 % with a kappa value 0.92 was resulted from the classification scheme, while accuracy differences among the classes were kept minimal. Finally, the results highlighted the importance of using very high-resolution satellite images for delineating the complex land use cover in the dry lands of the Eastern Nile Basin. Key Words: Multi-resolution segmentation; feature space optimisation; land use/land cover mapping; Eastern Nile Basin

  16. Lowered threshold energy for femtosecond laser induced optical breakdown in a water based eye model by aberration correction with adaptive optics.

    PubMed

    Hansen, Anja; Géneaux, Romain; Günther, Axel; Krüger, Alexander; Ripken, Tammo

    2013-06-01

    In femtosecond laser ophthalmic surgery tissue dissection is achieved by photodisruption based on laser induced optical breakdown. In order to minimize collateral damage to the eye laser surgery systems should be optimized towards the lowest possible energy threshold for photodisruption. However, optical aberrations of the eye and the laser system distort the irradiance distribution from an ideal profile which causes a rise in breakdown threshold energy even if great care is taken to minimize the aberrations of the system during design and alignment. In this study we used a water chamber with an achromatic focusing lens and a scattering sample as eye model and determined breakdown threshold in single pulse plasma transmission loss measurements. Due to aberrations, the precise lower limit for breakdown threshold irradiance in water is still unknown. Here we show that the threshold energy can be substantially reduced when using adaptive optics to improve the irradiance distribution by spatial beam shaping. We found that for initial aberrations with a root-mean-square wave front error of only one third of the wavelength the threshold energy can still be reduced by a factor of three if the aberrations are corrected to the diffraction limit by adaptive optics. The transmitted pulse energy is reduced by 17% at twice the threshold. Furthermore, the gas bubble motions after breakdown for pulse trains at 5 kilohertz repetition rate show a more transverse direction in the corrected case compared to the more spherical distribution without correction. Our results demonstrate how both applied and transmitted pulse energy could be reduced during ophthalmic surgery when correcting for aberrations. As a consequence, the risk of retinal damage by transmitted energy and the extent of collateral damage to the focal volume could be minimized accordingly when using adaptive optics in fs-laser surgery. PMID:23761849

  17. Lowered threshold energy for femtosecond laser induced optical breakdown in a water based eye model by aberration correction with adaptive optics

    PubMed Central

    Hansen, Anja; Géneaux, Romain; Günther, Axel; Krüger, Alexander; Ripken, Tammo

    2013-01-01

    In femtosecond laser ophthalmic surgery tissue dissection is achieved by photodisruption based on laser induced optical breakdown. In order to minimize collateral damage to the eye laser surgery systems should be optimized towards the lowest possible energy threshold for photodisruption. However, optical aberrations of the eye and the laser system distort the irradiance distribution from an ideal profile which causes a rise in breakdown threshold energy even if great care is taken to minimize the aberrations of the system during design and alignment. In this study we used a water chamber with an achromatic focusing lens and a scattering sample as eye model and determined breakdown threshold in single pulse plasma transmission loss measurements. Due to aberrations, the precise lower limit for breakdown threshold irradiance in water is still unknown. Here we show that the threshold energy can be substantially reduced when using adaptive optics to improve the irradiance distribution by spatial beam shaping. We found that for initial aberrations with a root-mean-square wave front error of only one third of the wavelength the threshold energy can still be reduced by a factor of three if the aberrations are corrected to the diffraction limit by adaptive optics. The transmitted pulse energy is reduced by 17% at twice the threshold. Furthermore, the gas bubble motions after breakdown for pulse trains at 5 kilohertz repetition rate show a more transverse direction in the corrected case compared to the more spherical distribution without correction. Our results demonstrate how both applied and transmitted pulse energy could be reduced during ophthalmic surgery when correcting for aberrations. As a consequence, the risk of retinal damage by transmitted energy and the extent of collateral damage to the focal volume could be minimized accordingly when using adaptive optics in fs-laser surgery. PMID:23761849

  18. Chemical and thermal injuries of the eyes. Surgical and medical treatment based on clinical and pathophysiological findings.

    PubMed

    Reim, M; Redbrake, C; Schrage, N

    2001-02-01

    Light burns heal well within a few days. Severe chemical and thermal injuries of the eyes destroy surface epithelia and cause ischemic necroses of conjunctiva, cornea, sclera, iris, ciliary body, and lids. An inflammatory response follows with leucocyte infiltration and release of inflammatory mediators. Prostaglandins, lipoxygenase products, cytokines, superoxide radicals and Iysosomal enzymes are known to be active in eye burn disease. Their activities result in corneal, scleral and conjunctival ulceration, tissue proliferation and scarification, which develop within weeks, months and even years after the accident. Pathophysiological events produce defined clinical pictures. Some agents take special actions, e.g. alkali penetrates within seconds into the anterior chamber, sulfuric acid burns as well as quick lime burns forming slaked lime produce considerable heat. Hydrofluoric acid is highly toxic and induces early necroses. Heat causes deep ischemic necroses and lateron strongly shrinking scars. Onset and intensity of first aid decided on the outcome. Immediate rinsing is essential. Cool water, saline, Ringers lactate solution and BSS are good rinsing media. For first aid, buffered Previn seems suitable. Major chemical and thermal injuries need a variety of medical and surgical treatments: Necroses must be excised surgically. Tenon plasty is performed to reconstruct conjunctiva. Amnion-, limbus- and early keratoplasty or artificial epithelium are applied, initially to save the cornea from melting, and later to restore vision. Conjunctical, lid and intraocular surgery may be necessary. The aim of medical treatment is to suppress the inflammatory response and to prevent infection. Corticosteroids, antibiotics, ascorbate and inhibitors of proteolytic enzymes are used. Secondary glaucoma must not be forgotten. Extensive therapy is sometimes rewarding, results are presented. PMID:11228610

  19. One-step detection of pathogens and cancer biomarkers by the naked eye based on aggregation of immunomagnetic beads

    NASA Astrophysics Data System (ADS)

    Chen, Yiping; Xianyu, Yunlei; Sun, Jiashu; Niu, Yajing; Wang, Yu; Jiang, Xingyu

    2015-12-01

    This report shows that immunomagnetic beads (IMBs) can act as the optical readout for assays, in addition to serving as the carrier for purification/separation. Under the influence of an external magnet, IMBs are attracted to coat one side of a test tube. IMBs specifically bound to targets can form a narrow brown stripe, whereas free IMBs will form a diffuse, yellow coating on the side of the test tube. Target analytes can aggregate initially dispersed IMBs in a sample concentration-dependent manner, yielding a color change from yellow to brown that can be seen with the naked eye. This assay combines the convenience of a lateral flow assay, allowing a one-step assay to finish within 15 min, with the sensitivity of an enzyme-linked immonosorbent assay.This report shows that immunomagnetic beads (IMBs) can act as the optical readout for assays, in addition to serving as the carrier for purification/separation. Under the influence of an external magnet, IMBs are attracted to coat one side of a test tube. IMBs specifically bound to targets can form a narrow brown stripe, whereas free IMBs will form a diffuse, yellow coating on the side of the test tube. Target analytes can aggregate initially dispersed IMBs in a sample concentration-dependent manner, yielding a color change from yellow to brown that can be seen with the naked eye. This assay combines the convenience of a lateral flow assay, allowing a one-step assay to finish within 15 min, with the sensitivity of an enzyme-linked immonosorbent assay. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr07044a

  20. Infrared eye: an operational prototype

    NASA Astrophysics Data System (ADS)

    Chevrette, Paul C.; Fortin, Jean; St-Germain, Daniel; Delisle, Jean

    1998-09-01

    A new concept of surveillance system called Wide Area Coverage Infrared Surveillance System (WACISS), based on the human vision, was developed and a first laboratory prototype was demonstrated recently. A second prototype, more operational, is named the Infrared Eye is being built and will be tested in cooperation with the NRCC Flight Research Laboratory. The Infrared Eye will use the new pixel-less quantum well infrared photodetector sensors, coupled to light emitting diodes (QWIP/LED), currently being developed at NRCC Institute for Microstructural Science under DREV sponsorship. The multiple advantages of the pixel-less QWIP/LED over conventional sensors will considerably simplify the design of the system. As the WACISS, the IR Eye will integrate two cameras: the first, with a wide field-of- view, will be used for detection while the second camera, with a narrower field with higher resolution for identification, will be mobile within the WFOV and slaved to the operator's line-of-sight by means of an eye-tracking system. The images from both cameras will be fused and shown simultaneously on a standard high resolution CRT display unit, interfaced with the eye-tracking unit. The basic concepts pertaining to the project and the design constraints of this second prototype are presented.

  1. Best practice eye care models

    PubMed Central

    Qureshi, Babar M; Mansur, Rabiu; Al-Rajhi, Abdulaziz; Lansingh, Van; Eckert, Kristen; Hassan, Kunle; Ravilla, Thulasiraj; Muhit, Mohammad; Khanna, Rohit C; Ismat, Chaudhry

    2012-01-01

    Since the launching of Global Initiative, VISION 2020 “the Right to Sight” many innovative, practical and unique comprehensive eye care services provision models have evolved targeting the underserved populations in different parts of the World. At places the rapid assessment of the burden of eye diseases in confined areas or utilizing the key informants for identification of eye diseases in the communities are promoted for better planning and evidence based advocacy for getting / allocation of resources for eye care. Similarly for detection and management of diabetes related blindness, retinopathy of prematurity and avoidable blindness at primary level, the major obstacles are confronted in reaching to them in a cost effective manner and then management of the identified patients accordingly. In this regard, the concept of tele-ophthalmology model sounds to be the best solution. Whereas other models on comprehensive eye care services provision have been emphasizing on surgical output through innovative scales of economy that generate income for the program and ensure its sustainability, while guaranteeing treatment of the poorest of the poor. PMID:22944741

  2. Eye mechanics and their implications for eye movement control

    NASA Astrophysics Data System (ADS)

    Koene, Ansgar Roald

    2002-11-01

    The topic of this thesis is the investigation of the mechanical properties of the oculomotor system and the implications of these properties for eye movement control. The investigation was conducted by means of computer models and simulations. This allowed us to combine data from anatomy, physiology and psychophysics with basic principles of physics (mechanics) and mathematics (geometry). In chapter 2 we investigate the degree to which mechanical and neural non-linearities contribute to the kinematic differences between centrifugal and centripetal saccades. On the basis of the velocity profiles of centrifugal and centripetal saccades we calculate the forces and muscle innervations during these eye movements. This was done using an inverted model of the eye plant. Our results indicate that the non-linear force-velocity relationship (i.e. muscle viscosity) of the muscles is probably the cause of the kinematic differences between centrifugal and centripetal saccades. In chapter 3 we calculate the adjustment of the saccadic command that is necessary to compensate for the eye plant non-linearities. These calculations show that the agonist and antagonist muscles require different net saccade signal gain changes. In order to better understand how this gain change is accomplished we use the inverted model of the eye plant (chapter 2) to calculate the muscle innervation profiles of saccades with different starting orientations. Based on these calculations we conclude that the saccade signal gain changes are accomplished primarily by changes in the magnitude of the saccade signal. In chapter 4 we examine the requirements that the oculomotor system must meet for the eye to be able to make desired gaze changes and fixate at various eye orientations. We first determine how the axes of action (i.e. unit moment vectors) of the muscles are related to eye orientation and the location of the effective muscle origin (i.e. the muscle pulleys). Next we show how this relation constrains

  3. Optical properties of the mouse eye

    PubMed Central

    Geng, Ying; Schery, Lee Anne; Sharma, Robin; Dubra, Alfredo; Ahmad, Kamran; Libby, Richard T.; Williams, David R.

    2011-01-01

    The Shack-Hartmann wavefront sensor (SHWS) spots upon which ocular aberration measurements depend have poor quality in mice due to light reflected from multiple retinal layers. We have designed and implemented a SHWS that can favor light from a specific retinal layer and measured monochromatic aberrations in 20 eyes from 10 anesthetized C57BL/6J mice. Using this instrument, we show that mice are myopic, not hyperopic as is frequently reported. We have also measured longitudinal chromatic aberration (LCA) of the mouse eye and found that it follows predictions of the water-filled schematic mouse eye. Results indicate that the optical quality of the mouse eye assessed by measurement of its aberrations is remarkably good, better for retinal imaging than the human eye. The dilated mouse eye has a much larger numerical aperture (NA) than that of the dilated human eye (0.5 NA vs. 0.2 NA), but it has a similar amount of root mean square (RMS) higher order aberrations compared to the dilated human eye. These measurements predict that adaptive optics based on this method of wavefront sensing will provide improvements in retinal image quality and potentially two times higher lateral resolution than that in the human eye. PMID:21483598

  4. Bologna with Student Eyes, 2007

    ERIC Educational Resources Information Center

    Mikkola, Anne, Ed.; Carapinha, Bruno, Ed.; Tuck, Colin, Ed.; MacSithigh, Daithi, Ed.; Aberg, Nina Gustaffson, Ed.; Brus, Sanja, Ed.

    2007-01-01

    "Bologna with Student Eyes" is a survey published by the National Unions of Students in Europe, based on questionnaires sent to national unions across the continent. The survey gives a broad overview of student union perspectives as to national implementations of Bologna Process Action Lines in the period 2005-2007. It addresses the topics of:…

  5. Occupational exposure to the whole body, extremities and to the eye lens in interventional radiology in Poland, as based on personnel dosimetry records at IFJ PAN

    NASA Astrophysics Data System (ADS)

    Szumska, Agnieszka; Budzanowski, M.; Kopeć, R.

    2014-11-01

    We report results of measurements of Hp(10) from whole body dosimeters (about 53 thousand readouts), of Hp(0.07) from finger ring dosimeters (23 thousand readouts) and of Hp(3) from eye lens dosimeters (100 readouts), issued in the years 2010-12 to over 150 medical departments in Poland which apply X-rays in radiology, interventional radiology (haemodynamic, angiology, cardiac surgery), urology, orthopaedics, electrophysiology or electro-cardiology. In all measurements thermoluminescence detectors (TLD) were used: the well-known standard MTS-N (LiF:Mg, Ti) for whole body and extremity dosimetry, and the high-sensitivity MCP-N (LiF:Mg, Cu, P) for eye lens dosimetry and environmental monitoring. We analysed the data base of the accredited Laboratory of Individual and Environmental Dosimetry (LADIS) at the Institute of Nuclear Physics PAN which offers its dosimetry service to these departments on a regular basis. We found that in the population of radiation workers that studied over the years 2010-2012 in 84%, 87%, and 34% of Hp(10), Hp(0.07) and Hp(3) measurements, respectively, the level of 0.1 mSv/quarter did not exceed, indicating lack of their occupational exposure. In the remaining 16%, 13% and 66% of individual cases, the 0.1 mSv/quarter exceeded, occasionally reaching several hundreds of mSv/quarter.

  6. On the comparison of visual discomfort generated by S3D and 2D content based on eye-tracking features

    NASA Astrophysics Data System (ADS)

    Iatsun, Iana; Larabi, Mohamed-Chaker; Fernandez-Maloigne, Christine

    2014-03-01

    The changing of TV systems from 2D to 3D mode is the next expected step in the telecommunication world. Some works have already been done to perform this progress technically, but interaction of the third dimension with humans is not yet clear. Previously, it was found that any increased load of visual system can create visual fatigue, like prolonged TV watching, computer work or video gaming. But watching S3D can cause another nature of visual fatigue, since all S3D technologies creates illusion of the third dimension based on characteristics of binocular vision. In this work we propose to evaluate and compare the visual fatigue from watching 2D and S3D content. This work shows the difference in accumulation of visual fatigue and its assessment for two types of content. In order to perform this comparison eye-tracking experiments using six commercially available movies were conducted. Healthy naive participants took part into the test and gave their answers feeling the subjective evaluation. It was found that watching stereo 3D content induce stronger feeling of visual fatigue than conventional 2D, and the nature of video has an important effect on its increase. Visual characteristics obtained by using eye-tracking were investigated regarding their relation with visual fatigue.

  7. A dynamic response and eye scanning data base useful in the development of theories and methods for the description of control/display relationships

    NASA Technical Reports Server (NTRS)

    Klein, R.

    1972-01-01

    A set of specially prepared digital tapes is reported which contain synchronized measurements of pilot scanning behavior, control response, and vehicle response obtained during instrument landing system approaches made in a fixed-base DC-8 transport simulator. The objective of the master tape is to provide a common data base which can be used by the research community to test theories, models, and methods for describing and analyzing control/display relations and interactions. The experimental conditions and tasks used to obtain the data and the detailed format of the tapes are described. Conventional instrument panel and controls were used, with simulated vertical gust and glide slope beam bend forcing functions. Continuous pilot eye fixations and scan traffic on the panel were measured. Both flight director and standard localizer/glide slope types of approaches were made, with both fixed and variable instrument range sensitivities.

  8. The Role of Biological Agents and Immunomodulators in Treatment Strategies for Thyroid Eye Disease: An Evidence-based Review.

    PubMed

    Ginter, Anna; Migliori, Michael E

    2016-01-01

    Graves' Disease is an autoimmune disease where circulating antibodies bind to the thyrotropin receptors on the thyroid gland. These bound antibodies mimic thyroid stimulating hormone without the normal feedback from the anterior pituitary, causing hyperthyroidism and thyrotoxicosis. These antibodies also interact with orbital tissues and cause the characteristic orbital findings of thyroid eye disease (TED). It is not clearly understood why anatomically and physiologically distinct tissues like the thyroid gland and orbit are affected selectively, or why the orbital disease tends to be self-limited. Identifying and understanding these processes is critical to targeting therapy. In the active phase of the disease patients may experience orbital inflammation, eyelid and conjunctiva edema (chemosis), eyelid retraction, proptosis, ocular motility restriction, and optic nerve compression. Current treatment strategies for the ocular symptoms have been predominantly directed at symptomatic relief. More recently, investigators have concentrated their efforts to better understanding the underlying pathophysiologic processes to direct therapy at these processes. This review examines the current literature exploring a variety of newer therapeutic alternatives, including immunomodulative and suppressive agents, targeted at strategic points of the active-phase TED pathophysiological pathways. Specifically, biological agents including rituximab, adalimumab, intravenous immunoglobulin and others are reviewed with considerations for pathophysiology, extent of literature support, and adverse effects. [Full article available at http://rimed.org/rimedicaljournal-2016-06.asp, free with no login]. PMID:27247969

  9. Prevention of Eye Injuries

    PubMed Central

    Pashby, Tom

    1981-01-01

    In Canada 30,000 people are registered as blind; in one third of these, blindness might have been avoided. Prevention is the key to reducing the number of eye injuries and blind eyes. The role of the family physician in early identification of treatable conditions and in the education of patients is discussed, but responsibility for prevention belongs to all physicians. The success of prevention is seen in the great reduction in eye injuries in industry and sports since eye protectors have been commonly used. However, many dangers to the eyes are either not recognized or are not taken seriously enough. This paper discusses some of the common causes of serious eye injuries in the home, in sports and in industry. Imagesp464-aFig. 1Fig. 2Fig. 3Fig. 4 PMID:21289691

  10. Benefits of Red-Edge Spectral Band and Texture Features for the Object-based Classification using RapidEye sSatellite Image data

    NASA Astrophysics Data System (ADS)

    Kim, H. O.; Yeom, J. M.

    2014-12-01

    Space-based remote sensing in agriculture is particularly relevant to issues such as global climate change, food security, and precision agriculture. Recent satellite missions have opened up new perspectives by offering high spatial resolution, various spectral properties, and fast revisit rates to the same regions. Here, we examine the utility of broadband red-edge spectral information in multispectral satellite image data for classifying paddy rice crops in South Korea. Additionally, we examine how object-based spectral features affect the classification of paddy rice growth stages. For the analysis, two seasons of RapidEye satellite image data were used. The results showed that the broadband red-edge information slightly improved the classification accuracy of the crop condition in heterogeneous paddy rice crop environments, particularly when single-season image data were used. This positive effect appeared to be offset by the multi-temporal image data. Additional texture information brought only a minor improvement or a slight decline, although it is well known to be advantageous for object-based classification in general. We conclude that broadband red-edge information derived from conventional multispectral satellite data has the potential to improve space-based crop monitoring. Because the positive or negative effects of texture features for object-based crop classification could barely be interpreted, the relationships between the textual properties and paddy rice crop parameters at the field scale should be further examined in depth.

  11. Bio-inspired hemispherical compound eye camera

    NASA Astrophysics Data System (ADS)

    Xiao, Jianliang; Song, Young Min; Xie, Yizhu; Malyarchuk, Viktor; Jung, Inhwa; Choi, Ki-Joong; Liu, Zhuangjian; Park, Hyunsung; Lu, Chaofeng; Kim, Rak-Hwan; Li, Rui; Crozier, Kenneth B.; Huang, Yonggang; Rogers, John A.

    2014-03-01

    Compound eyes in arthropods demonstrate distinct imaging characteristics from human eyes, with wide angle field of view, low aberrations, high acuity to motion and infinite depth of field. Artificial imaging systems with similar geometries and properties are of great interest for many applications. However, the challenges in building such systems with hemispherical, compound apposition layouts cannot be met through established planar sensor technologies and conventional optics. We present our recent progress in combining optics, materials, mechanics and integration schemes to build fully functional artificial compound eye cameras. Nearly full hemispherical shapes (about 160 degrees) with densely packed artificial ommatidia were realized. The number of ommatidia (180) is comparable to those of the eyes of fire ants and bark beetles. The devices combine elastomeric compound optical elements with deformable arrays of thin silicon photodetectors, which were fabricated in the planar geometries and then integrated and elastically transformed to hemispherical shapes. Imaging results and quantitative ray-tracing-based simulations illustrate key features of operation. These general strategies seem to be applicable to other compound eye devices, such as those inspired by moths and lacewings (refracting superposition eyes), lobster and shrimp (reflecting superposition eyes), and houseflies (neural superposition eyes).

  12. Videos from the National Eye Institute: Eye Diseases

    MedlinePlus

    ... this page please turn Javascript on. Feature: Vision Videos from the National Eye Institute: Eye Diseases Past ... the early detection of eye disease. Share these videos with friends, family and colleagues. www.nei.nih. ...

  13. Range verification for eye proton therapy based on proton-induced x-ray emissions from implanted metal markers.

    PubMed

    La Rosa, Vanessa; Kacperek, Andrzej; Royle, Gary; Gibson, Adam

    2014-06-01

    Metal fiducial markers are often implanted on the back of the eye before proton therapy to improve target localization and reduce patient setup errors. We aim to detect characteristic x-ray emissions from metal targets during proton therapy to verify the treatment range accuracy. Initially gold was chosen for its biocompatibility properties. Proton-induced x-ray emissions (PIXE) from a 15 mm diameter gold marker were detected at different penetration depths of a 59 MeV proton beam at the CATANA proton facility at INFN-LNS (Italy). The Monte Carlo code Geant4 was used to reproduce the experiment and to investigate the effect of different size markers, materials, and the response to both mono-energetic and fully modulated beams. The intensity of the emitted x-rays decreases with decreasing proton energy and thus decreases with depth. If we assume the range to be the depth at which the dose is reduced to 10% of its maximum value and we define the residual range as the distance between the marker and the range of the beam, then the minimum residual range which can be detected with 95% confidence level is the depth at which the PIXE peak is equal to 1.96 σ(bkg), which is the standard variation of the background noise. With our system and experimental setup this value is 3 mm, when 20 GyE are delivered to a gold marker of 15 mm diameter. Results from silver are more promising. Even when a 5 mm diameter silver marker is placed at a depth equal to the range, the PIXE peak is 2.1 σ(bkg). Although these quantitative results are dependent on the experimental setup used in this research study, they demonstrate that the real-time analysis of the PIXE emitted by fiducial metal markers can be used to derive beam range. Further analysis are needed to demonstrate the feasibility of the technique in a clinical setup. PMID:24786372

  14. Photorefraction of the Eye

    ERIC Educational Resources Information Center

    Colicchia, Giuseppe; Wiesner, Hartmut; Zollman, Dean

    2015-01-01

    Photorefraction is a method to easily estimate the refractive state of the eye. The principle of photorefraction involves projecting light into the eye during flash photography and then examining the paths of light that emerge from the pupil after scattering on the back portion of the interior of the eyeball (fundus). We will explain the optical…

  15. Eye tissues study

    NASA Astrophysics Data System (ADS)

    Tuchin, Valery V.; Bashkatov, Alexey N.; Maksimova, Irina L.; Sinichkin, Yurii P.; Simonenko, Georgy V.; Genina, Elina A.; Lakodina, Nina A.

    2001-08-01

    Theoretical and in vitro and in vivo experimental study of spectral and polarization characteristics of the human and rabbit eye tissues are presented. The possibility of control of optical properties of eye cornea, lens and sclera is discussed and realized experimentally for glucose solution as the refractive index matching factor.

  16. Preventing Eye Injuries

    MedlinePlus

    ... Eye Injuries Reviewed by: Brenda Pagan-Duran MD Mar. 01, 2016 Protecting your eyes from injury is one of the most basic things you can do to keep your vision healthy throughout your life. You may be somewhat aware of the possible ...

  17. Lasik eye surgery - slideshow

    MedlinePlus

    ... this page: //medlineplus.gov/ency/presentations/100206.htm Lasik eye surgery - series To use the sharing features ... A.M. Editorial team. Related MedlinePlus Health Topics Laser Eye Surgery A.D.A.M., Inc. is accredited by ...

  18. Diabetes and eye disease

    MedlinePlus

    ... the back of the inner eye. It changes light and images that enter the eye into nerve signals, which are sent to the brain. Diabetic retinopathy is a main cause of decreased vision or blindness in Americans 20 to 74 years old. People with type 1 or type 2 ...

  19. Fluorescein eye stain

    MedlinePlus

    ... eye. The health care provider then shines a blue light at your eye. Any problems on the surface of the cornea will be stained by the dye and appear green under the blue light. The provider can determine the location and ...

  20. Understanding pink eye

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Pink eye (PE) is a physiological tuber disorder that can result in serious processing complications and storage losses. The earliest external symptoms consist of an ephemeral pinkish discoloration around tuber eyes, predominately at the bud end of the tuber. These pinkish areas can then develop into...

  1. An Eye for Learning.

    ERIC Educational Resources Information Center

    Ostwald, Thomas

    1995-01-01

    Presents a hands-on activity as an excellent starting point for investigations related to the eye. Involves making a simple model of the vertebrate eye to illustrate the formation of an upside-down image on the retina by the lens. Links to investigations in numerous science disciplines including astronomy, genetics, biology, earth science, and…

  2. Smoking and Eye Health

    MedlinePlus

    ... Eye Health Apr. 14, 2014 Avoiding smoking and second hand smoke — or quitting if you are a smoker — are ... influence your eyes’ health. And tobacco smoke, including second-hand smoke, is an irritant that worsens dry eye , a ...

  3. Eye burning - itching and discharge

    MedlinePlus

    ... allergies or hay fever Infections, bacterial or viral ( conjunctivitis or pink eye) Chemical irritants (such as chlorine ... to help with allergies. Pink eye or viral conjunctivitis causes a red or bloodshot eye and excessive ...

  4. Estimating peak skin and eye lens dose from neuroperfusion examinations: Use of Monte Carlo based simulations and comparisons to CTDIvol, AAPM Report No. 111, and ImPACT dosimetry tool values

    PubMed Central

    Zhang, Di; Cagnon, Chris H.; Villablanca, J. Pablo; McCollough, Cynthia H.; Cody, Dianna D.; Zankl, Maria; Demarco, John J.; McNitt-Gray, Michael F.

    2013-01-01

    Purpose: CT neuroperfusion examinations are capable of delivering high radiation dose to the skin or lens of the eyes of a patient and can possibly cause deterministic radiation injury. The purpose of this study is to: (a) estimate peak skin dose and eye lens dose from CT neuroperfusion examinations based on several voxelized adult patient models of different head size and (b) investigate how well those doses can be approximated by some commonly used CT dose metrics or tools, such as CTDIvol, American Association of Physicists in Medicine (AAPM) Report No. 111 style peak dose measurements, and the ImPACT organ dose calculator spreadsheet. Methods: Monte Carlo simulation methods were used to estimate peak skin and eye lens dose on voxelized patient models, including GSF's Irene, Frank, Donna, and Golem, on four scanners from the major manufacturers at the widest collimation under all available tube potentials. Doses were reported on a per 100 mAs basis. CTDIvol measurements for a 16 cm CTDI phantom, AAPM Report No. 111 style peak dose measurements, and ImPACT calculations were performed for available scanners at all tube potentials. These were then compared with results from Monte Carlo simulations. Results: The dose variations across the different voxelized patient models were small. Dependent on the tube potential and scanner and patient model, CTDIvol values overestimated peak skin dose by 26%–65%, and overestimated eye lens dose by 33%–106%, when compared to Monte Carlo simulations. AAPM Report No. 111 style measurements were much closer to peak skin estimates ranging from a 14% underestimate to a 33% overestimate, and with eye lens dose estimates ranging from a 9% underestimate to a 66% overestimate. The ImPACT spreadsheet overestimated eye lens dose by 2%–82% relative to voxelized model simulations. Conclusions: CTDIvol consistently overestimates dose to eye lens and skin. The ImPACT tool also overestimated dose to eye lenses. As such they are still

  5. Object-Based Visual Attention in 8-Month-Old Infants: Evidence from an Eye-Tracking Study

    ERIC Educational Resources Information Center

    Bulf, Hermann; Valenza, Eloisa

    2013-01-01

    Visual attention is one of the infant's primary tools for gathering relevant information from the environment for further processing and learning. The space-based component of visual attention in infants has been widely investigated; however, the object-based component of visual attention has received scarce interest. This scarcity is…

  6. [Treatment of eye allergies].

    PubMed

    Kari, Osmo; Saari, K Matti

    2012-01-01

    Seasonal atopic conjunctivitis is treated with antihistamines, cromoglycate and short courses of corticosteroids, in severe cases with subcutaneous or sublingual immunotherapy. Chronic conjunctivitis requires year-round treatment with mast cell stabilizers, antihistamines or topical corticosteroids. Long-term treatment of atopic blepharoconjunctivitis consists of tacrolimus or pimecrolimus cream. For atopic keratoconjunctivitis corticosteroid and, if necessary, cyclosporine eye drops are needed. First-line therapy of vernal conjunctivitis involves mast cell stabilizers and, if necessary, corticosteroid eye drops. Treatment of non-allergic eosinophilic conjunctivitis involves mast cell stabilizers, corticosteroid and, if necessary, cyclosporine eye drops. PMID:22428383

  7. Eye-Safe Lidar

    NASA Technical Reports Server (NTRS)

    Byer, Robert L.

    1989-01-01

    Laser infrared radar (lidar) undergoing development harmless to human eyes, consists almost entirely of solid-state components, and offers high range resolution. Operates at wavelength of about 2 micrometers. If radiation from such device strikes eye, almost completely absorbed by cornea without causing damage, even if aimed directly at eye. Continuous-wave light from laser oscillator amplified and modulated for transmission from telescope. Small portion of output of oscillator fed to single-mode fiber coupler, where mixed with return pulses. Intended for remote Doppler measurements of winds and differential-absorption measurements of concentrations of gases in atmosphere.

  8. Modelling human eye under blast loading.

    PubMed

    Esposito, L; Clemente, C; Bonora, N; Rossi, T

    2015-01-01

    Primary blast injury (PBI) is the general term that refers to injuries resulting from the mere interaction of a blast wave with the body. Although few instances of primary ocular blast injury, without a concomitant secondary blast injury from debris, are documented, some experimental studies demonstrate its occurrence. In order to investigate PBI to the eye, a finite element model of the human eye using simple constitutive models was developed. The material parameters were calibrated by a multi-objective optimisation performed on available eye impact test data. The behaviour of the human eye and the dynamics of mechanisms occurring under PBI loading conditions were modelled. For the generation of the blast waves, different combinations of explosive (trinitrotoluene) mass charge and distance from the eye were analysed. An interpretation of the resulting pressure, based on the propagation and reflection of the waves inside the eye bulb and orbit, is proposed. The peculiar geometry of the bony orbit (similar to a frustum cone) can induce a resonance cavity effect and generate a pressure standing wave potentially hurtful for eye tissues. PMID:23521031

  9. How to perform irrigation of the eye.

    PubMed

    Marsden, Janet

    2016-02-01

    rationale and key points: This article aims to help nurses to understand the importance of performing irrigation immediately following chemical injury to the eye, and outlines the most effective technique. It is essential that irrigation of the eye is understood and performed correctly. Chemical injury to the eye is an ophthalmic emergency. It presents a serious risk to the patient's vision and may cause blindness. The length of time the chemical remains in contact with the eye determines the severity of the injury. Immediate irrigation of the eye is essential to minimise preventable loss of vision. REFLECTIVE ACTIVITY: Clinical skills articles can help update your practice and ensure it remains evidence based. Apply this article to your practice. Reflect on and write a short account of: 1. How you would ensure immediate irrigation following chemical injury to the eye in your clinical area. 2. How you know when you have irrigated the eye for long enough, if you have previously performed this procedure, and how reading this article might influence your practice. Subscribers can upload their reflective accounts at: rcni.com/portfolio . PMID:26838655

  10. Brain-machine interface for eye movements.

    PubMed

    Graf, Arnulf B A; Andersen, Richard A

    2014-12-01

    A number of studies in tetraplegic humans and healthy nonhuman primates (NHPs) have shown that neuronal activity from reach-related cortical areas can be used to predict reach intentions using brain-machine interfaces (BMIs) and therefore assist tetraplegic patients by controlling external devices (e.g., robotic limbs and computer cursors). However, to our knowledge, there have been no studies that have applied BMIs to eye movement areas to decode intended eye movements. In this study, we recorded the activity from populations of neurons from the lateral intraparietal area (LIP), a cortical node in the NHP saccade system. Eye movement plans were predicted in real time using Bayesian inference from small ensembles of LIP neurons without the animal making an eye movement. Learning, defined as an increase in the prediction accuracy, occurred at the level of neuronal ensembles, particularly for difficult predictions. Population learning had two components: an update of the parameters of the BMI based on its history and a change in the responses of individual neurons. These results provide strong evidence that the responses of neuronal ensembles can be shaped with respect to a cost function, here the prediction accuracy of the BMI. Furthermore, eye movement plans could be decoded without the animals emitting any actual eye movements and could be used to control the position of a cursor on a computer screen. These findings show that BMIs for eye movements are promising aids for assisting paralyzed patients. PMID:25422454

  11. In the eye of the beholder: a survey of models for eyes and gaze.

    PubMed

    Hansen, Dan Witzner; Ji, Qiang

    2010-03-01

    Despite active research and significant progress in the last 30 years, eye detection and tracking remains challenging due to the individuality of eyes, occlusion, variability in scale, location, and light conditions. Data on eye location and details of eye movements have numerous applications and are essential in face detection, biometric identification, and particular human-computer interaction tasks. This paper reviews current progress and state of the art in video-based eye detection and tracking in order to identify promising techniques as well as issues to be further addressed. We present a detailed review of recent eye models and techniques for eye detection and tracking. We also survey methods for gaze estimation and compare them based on their geometric properties and reported accuracies. This review shows that, despite their apparent simplicity, the development of a general eye detection technique involves addressing many challenges, requires further theoretical developments, and is consequently of interest to many other domains problems in computer vision and beyond. PMID:20075473

  12. The Perfect Eye A Novel Model for Teaching the Theory of Refraction.

    ERIC Educational Resources Information Center

    Kurtz, Daniel

    1999-01-01

    The Perfect Eye model simplifies solutions to a wide variety of optometry instructional problems by facilitating student understanding of the interaction among lenses, objects, accommodation, and ametropia. The model is based on the premise that inside every eye is a perfect (emmetropic) eye, and that the physiological eye is a combination of the…

  13. Faith-Based Media Literacy Education: A Look at the Past with an Eye toward the Future

    ERIC Educational Resources Information Center

    Iaquinto, Stephanie; Keeler, John

    2012-01-01

    This article addresses several fundamental questions about faith-based media literacy education in the United States, including how the assumptions, motivations, goals, and pedagogy of those Christians who are operating within a media literacy framework come together to create a unique approach to teaching media literacy. After briefly reviewing…

  14. "Kindergarten, can I have your eyes and ears?" politeness and teacher directive choices in inquiry-based science classrooms

    NASA Astrophysics Data System (ADS)

    Oliveira, Alandeom Wanderlei

    2009-12-01

    This study explores elementary teachers' social understandings and employment of directives and politeness while facilitating inquiry science lessons prior and subsequent to their participation in a summer institute in which they were introduced to the scholarly literature on regulative discourse (directives used by teachers to regulate student behavior). A grounded theory analysis of the institute professional development activities revealed that teachers developed an increased awareness of the authoritative functions served by impolite or direct directives (i.e., pragmatic awareness). Furthermore, a comparative microethnographic analysis of participants' inquiry-based classroom practices revealed that after the institute teachers demonstrated an increased ability to share authority with students by strategically making directive choices that were more polite, indirect, inclusive, involvement-focused and creative. Such ability led to a reduced emphasis on teacher regulation of student compliance with classroom behavioral norms and an increased focus on the discursive organization of the inquiry-based science learning/teaching process. Despite teachers' increased pragmatic awareness, teacher-student linguistic relationships did not become entirely symmetrical subsequent to their participation in the summer institute (i.e., teacher authority was not completely relinquished or lost). Based on such findings, it is argued that teachers need to develop higher levels of pragmatic awareness to become effectively prepared to engage in language-mediated teacher-student interaction in the context of inquiry-based science classroom discourse.

  15. Diabetic Eye Disease

    MedlinePlus

    ... Health Education Program Diabetic Eye Disease Education Program Glaucoma Education Program Low Vision Education Program Spanish-language ... FAQ Watch out for your vision! Glossary Resources Glaucoma Glaucoma Home How Much Do You Know? What ...

  16. Dry eye syndrome

    MedlinePlus

    ... of dry eyes include: Dry environment or workplace (wind, air conditioning) Sun exposure Smoking or second-hand ... NOT smoke and avoid second-hand smoke, direct wind, and air conditioning. Use a humidifier, especially in ...

  17. Amblyopia: Lazy Eye Treatment

    MedlinePlus

    ... Choosing Safe Toys this Holiday Dec 02, 2015 Digital Glasses For Lazy Eye Nov 19, 2015 Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About ...

  18. Amblyopia: Lazy Eye Symptoms

    MedlinePlus

    ... Choosing Safe Toys this Holiday Dec 02, 2015 Digital Glasses For Lazy Eye Nov 19, 2015 Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About ...

  19. Amblyopia: Lazy Eye Diagnosis

    MedlinePlus

    ... Choosing Safe Toys this Holiday Dec 02, 2015 Digital Glasses For Lazy Eye Nov 19, 2015 Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About ...

  20. What Is Dry Eye?

    MedlinePlus

    ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Academy Publications EyeNet Ophthalmology Information for: International Ophthalmologists Media Medical Students Patients and Public Technicians and Nurses ...

  1. Down Syndrome: Eye Problems

    MedlinePlus

    American Association for Pediatric Ophthalmology and Strabismus Home About AAPOS Patient Info Resources Allied Health News & Events Meetings J AAPOS American Association for Pediatric Ophthalmology and Strabismus Eye Terms ...

  2. Fungal Eye Infections

    MedlinePlus

    ... Zoonotic Infectious Disease Division of Foodborne, Waterborne, and Environmental Diseases Mycotic Diseases Branch Fungal Eye Infections Recommend on ... Zoonotic Infectious Disease Division of Foodborne, Waterborne, and Environmental Diseases Mycotic Diseases Branch File Formats Help: How do ...

  3. Dry eye syndrome

    MedlinePlus

    ... particles that have gotten in. A healthy tear film on the eye is necessary for good vision. ... exam Diagnostic staining of the cornea and tear film Measurement of tear film break-up time (TBUT) ...

  4. Using Eye Makeup

    MedlinePlus

    ... in a moving vehicle. Do not separate your mascara-clumped lashes with sharp items. If you tend ... all eye makeup at night before sleeping, especially mascara that can stick to the lashes. Brush a ...

  5. Anatomy of the Eye

    MedlinePlus

    ... Conditions Frequently Asked Questions Español Condiciones Chinese Conditions Anatomy of the Eye En Español Read in Chinese External (Extraocular) Anatomy Extraocular Muscles: There are six muscles that are ...

  6. Melanoma of the eye

    MedlinePlus

    ... modified July 9, 2015. www.cancer.gov/types/eye/hp/intraocular-melanoma-treatment-pdq . Accessed October 7, 2015. Read ... by: Yi-Bin Chen, MD, Leukemia/Bone Marrow Transplant Program, Massachusetts General Hospital, Boston, MA. Also reviewed ...

  7. Eye Injuries in Sports

    MedlinePlus

    ... these injuries can be prevented. Overall, basketball and baseball cause the most eye injuries, followed by water ... involve body contact. Some high-risk sports are baseball, basketball, hockey, football, lacrosse, tennis and other racquet ...

  8. [Straight in the eyes].

    PubMed

    Diop, E; Beylot, V; Berta, C; Dugardin, C; Aigle, L

    2015-01-01

    This case report about a young French soldier hit in the eye by a spitting cobra in the Central African Republic prompts us to review the potential toxicity of this venom to the eyes and the management of this injury. The initial phase is simple to implement, but is often performed badly or not at all because unknown. It is a condition, however, for optimal recovery of the cornea. PMID:26067984

  9. Eye Tracking Young Children with Autism

    PubMed Central

    Sasson, Noah J.; Elison, Jed T.

    2012-01-01

    The rise of accessible commercial eye-tracking systems has fueled a rapid increase in their use in psychological and psychiatric research. By providing a direct, detailed and objective measure of gaze behavior, eye-tracking has become a valuable tool for examining abnormal perceptual strategies in clinical populations and has been used to identify disorder-specific characteristics1, promote early identification2, and inform treatment3. In particular, investigators of autism spectrum disorders (ASD) have benefited from integrating eye-tracking into their research paradigms4-7. Eye-tracking has largely been used in these studies to reveal mechanisms underlying impaired task performance8 and abnormal brain functioning9, particularly during the processing of social information1,10-11. While older children and adults with ASD comprise the preponderance of research in this area, eye-tracking may be especially useful for studying young children with the disorder as it offers a non-invasive tool for assessing and quantifying early-emerging developmental abnormalities2,12-13. Implementing eye-tracking with young children with ASD, however, is associated with a number of unique challenges, including issues with compliant behavior resulting from specific task demands and disorder-related psychosocial considerations. In this protocol, we detail methodological considerations for optimizing research design, data acquisition and psychometric analysis while eye-tracking young children with ASD. The provided recommendations are also designed to be more broadly applicable for eye-tracking children with other developmental disabilities. By offering guidelines for best practices in these areas based upon lessons derived from our own work, we hope to help other investigators make sound research design and analysis choices while avoiding common pitfalls that can compromise data acquisition while eye-tracking young children with ASD or other developmental difficulties. PMID:22491039

  10. Eye Protection in Educational Institutions.

    ERIC Educational Resources Information Center

    New Jersey State Dept. of Education, Trenton. Div. of Vocational Education.

    Intended to help reduce the number of school eye injuries in New Jersey, this document begins with a brief review of existing legislation regarding eye protection in educational institutions and a list of elements essential in an eye safety program. Second, eye protection equipment is examined in terms of: the advantages of safety spectacles over…

  11. Eye Safety. Mississippi Industrial Arts.

    ERIC Educational Resources Information Center

    Mississippi State Dept. of Education, Jackson. Div. of Vocational and Technical Education.

    This manual is designed to help industrial arts teachers eliminate student eye injuries within industrial arts programs. Presented first is Mississippi eye safety law. Following a discussion of eye protection equipment, illustrations of eye protection devices are provided. Guidelines are set forth for selecting shade numbers for welding filters.…

  12. Image based remote sensing method for modeling black-eyed beans ( Vigna unguiculata) Leaf Area Index (LAI) and Crop Height (CH) over Cyprus

    NASA Astrophysics Data System (ADS)

    Papadavid, Giorgos; Fasoula, Dionysia; Hadjimitsis, Michael; Skevi Perdikou, P.; Hadjimitsis, Diofantos G.

    2013-03-01

    In this paper, Leaf Area Index (LAI) and Crop Height (CH) are modeled to the most known spectral vegetation index — NDVI — using remotely sensed data. This approach has advantages compared to the classic approaches based on a theoretical background. A GER-1500 field spectro-radiometer was used in this study in order to retrieve the necessary spectrum data for estimating a spectral vegetation index (NDVI), for establishing a semiempirical relationship between black-eyed beans' canopy factors and remotely sensed data. Such semi-empirical models can be used then for agricultural and environmental studies. A field campaign was undertaken with measurements of LAI and CH using the Sun-Scan canopy analyzer, acquired simultaneously with the spectroradiometric (GER1500) measurements between May and June of 2010. Field spectroscopy and remotely sensed imagery have been combined and used in order to retrieve and validate the results of this study. The results showed that there are strong statistical relationships between LAI or CH and NDVI which can be used for modeling crop canopy factors (LAI, CH) to remotely sensed data. The model for each case was verified by the factor of determination. Specifically, these models assist to avoid direct measurements of the LAI and CH for all the dates for which satellite images are available and support future users or future studies regarding crop canopy parameters.

  13. Image based remote sensing method for modeling black-eyed beans (Vigna unguiculata) Leaf Area Index (LAI) and Crop Height (CH) over Cyprus

    NASA Astrophysics Data System (ADS)

    Papadavid, Giorgos; Fasoula, Dionysia; Hadjimitsis, Michael; Skevi Perdikou, P.; Hadjimitsis, Diofantos

    2013-03-01

    In this paper, Leaf Area Index (LAI) and Crop Height (CH) are modeled to the most known spectral vegetation index — NDVI — using remotely sensed data. This approach has advantages compared to the classic approaches based on a theoretical background. A GER-1500 field spectro-radiometer was used in this study in order to retrieve the necessary spectrum data for estimating a spectral vegetation index (NDVI), for establishing a semiempirical relationship between black-eyed beans' canopy factors and remotely sensed data. Such semi-empirical models can be used then for agricultural and environmental studies. A field campaign was undertaken with measurements of LAI and CH using the Sun-Scan canopy analyzer, acquired simultaneously with the spectroradiometric (GER1500) measurements between May and June of 2010. Field spectroscopy and remotely sensed imagery have been combined and used in order to retrieve and validate the results of this study. The results showed that there are strong statistical relationships between LAI or CH and NDVI which can be used for modeling crop canopy factors (LAI, CH) to remotely sensed data. The model for each case was verified by the factor of determination. Specifically, these models assist to avoid direct measurements of the LAI and CH for all the dates for which satellite images are available and support future users or future studies regarding crop canopy parameters.

  14. Rational design of a novel azoimine appended maleonitrile-based Salen chemosensor for rapid naked-eye detection of copper(II) ion in aqueous media.

    PubMed

    Rezaeian, Khatereh; Khanmohammadi, Hamid; Arab, Vajihe

    2015-12-01

    Achieving specific selectivity and high sensitivity for the colorimetric recognition of copper(II) ions in aqueous media over a complex background of potentially competing metal ions is inherently challenging in sensor development. Thus, a novel azo-azomethine receptor (L) based on the combination of 2-amino-3-(5-bromo-2-hydroxybenzylamino)maleonitrile and azo-coupled salicylaldehyde scaffold has been designed and synthesized for the naked-eye and rapid detection of Cu(2+) ion at trace level in a wide pH range. Accordingly, the devised chemosensor distinguished Cu(2+) from other metal ions by distinct color change from light yellow to light brown without any expensive equipment. The binding stoichiometry between Cu(2+) and L has been investigated using Job's plot and MALDI-TOF mass analysis. Remarkably, the current sensor can detect Cu(2+) ions even at 1.07 μM level, which is lower than the World Health Organization (WHO) permissible level (30 μM) in drinking water. Furthermore, sensor L was successfully utilized in the preparation of test strips for the detection of copper(II) ions from aqueous environment. PMID:26184468

  15. [Use of plasmapheresis-based extracorporeal hemocorrection in the treatment of endogenic uveitis and autoimmune eye diseases].

    PubMed

    Frolov, A B; Grechanyĭ, M P; Chentsova, O B

    2009-01-01

    The paper gives the methods of plasmapheresis-based extracorporeal exposure to blood and its components to correct hemostatic disorders. Afferent methods, as well as quantum hemotherapy methods are outlined. The immunomodulating mechanism of their action, which favors a prompter elimination of inflammation, increases ocular functions, and reduces recurrences, is revealed. The mechanisms of action of plasmapheresis as a technique used alone and in combination with laser and ultraviolet blood irradiation and indications for and contraindications to the use of various hemocorrection methods are described. PMID:19916339

  16. In pursuit of objective dry eye screening clinical techniques.

    PubMed

    Kanellopoulos, Anastasios John; Asimellis, George

    2016-01-01

    Dry eye is a multifactorial, progressive, and chronic disease of the tears and ocular surface. The disease is multi-factorial and has intermittent symptoms. Discomfort, visual disturbance, tear film instability with potential damage to the ocular surface, and increased tear film osmolarity are known associates. Dry eye is a common clinical problem for eye-care providers worldwide and there is a large number of clinical investigative techniques for the evaluation of dry eye. Despite this, however, there is no globally accepted guideline for dry eye diagnosis and none of the available tests may hold the title of the 'gold standard'. The majority of the techniques involved in the diagnosis of the disease, particularly for its early stages, has a large degree of subjectivity. The purpose of this article is to review existing dry eye investigative techniques and to present a new objective dry eye screening technique based on optical coherence tomography. PMID:26783543

  17. Dry Eye Disease and Microbial Keratitis: Is There a Connection?

    PubMed Central

    Narayanan, Srihari; Redfern, Rachel L.; Miller, William L.; Nichols, Kelly K.; McDermott, Alison M.

    2013-01-01

    Dry eye is a common ocular surface disease of multifactorial etiology characterized by elevated tear osmolality and inflammation leading to a disrupted ocular surface. The latter is a risk factor for ocular surface infection, yet overt infection is not commonly seen clinically in the typical dry eye patient. This suggests that important innate mechanisms operate to protect the dry eye from invading pathogens. This article reviews the current literature on epidemiology of ocular surface infection in dry eye patients and laboratory-based studies on innate immune mechanisms operating at the ocular surface and their alterations in human dry eye and animal models. The review highlights current understanding of innate immunity in dry eye and identifies gaps in our knowledge to help direct future studies to further unravel the complexities of dry eye disease and its sequelae. PMID:23583043

  18. Structural Neural Substrates of Reading the Mind in the Eyes

    PubMed Central

    Sato, Wataru; Kochiyama, Takanori; Uono, Shota; Sawada, Reiko; Kubota, Yasutaka; Yoshimura, Sayaka; Toichi, Motomi

    2016-01-01

    The ability to read the minds of others in their eyes plays an important role in human adaptation to social environments. Behavioral studies have resulted in the development of a test to measure this ability (Reading the Mind in the Eyes Test, revised version; Eyes Test), and have demonstrated that this ability is consistent over time. Although functional neuroimaging studies revealed brain activation while performing the Eyes Test, the structural neural substrates supporting consistent performance on the Eyes Test remain unclear. In this study, we assessed the Eyes Test and analyzed structural magnetic resonance images using voxel-based morphometry (VBM) in healthy participants. Test performance was positively associated with the gray matter volumes of the dorsomedial prefrontal cortex, inferior parietal lobule (temporoparietal junction), and precuneus in the left hemisphere. These results suggest that the fronto-temporoparietal network structures support the consistent ability to read the mind in the eyes. PMID:27148008

  19. The incidence of acute hospital-treated eye injuries.

    PubMed

    Karlson, T A; Klein, B E

    1986-10-01

    Little information is available on the incidence and severity of eye injuries despite the disfigurement and vision loss they cause. From a population-based study in Dane County, Wisconsin, the incidence of acute hospital-treated eye injuries was 423/100,000 residents in 1979. The most common causes of eye injuries were assaults, work-related events, sports and recreational activities, motor vehicle crashes, and falls. Consumer products were involved in almost 70% (9/13) of severe eye injuries classified as severe. Injuries from fireworks were not found at all in this population. Implementing known strategies for eye injury prevention would substantially reduce their incidence. These include requiring certified eye protectors at workplaces and in sports activities whenever possible rather than making their use voluntary. For the preponderance of eye injuries, however, modifying potentially hazardous consumer products, including the interior of passenger cars, will be necessary. PMID:3767676

  20. Development of infrared thermal imager for dry eye diagnosis

    NASA Astrophysics Data System (ADS)

    Chiang, Huihua Kenny; Chen, Chih Yen; Cheng, Hung You; Chen, Ko-Hua; Chang, David O.

    2006-08-01

    This study aims at the development of non-contact dry eye diagnosis based on an infrared thermal imager system, which was used to measure the cooling of the ocular surface temperature of normal and dry eye patients. A total of 108 subjects were measured, including 26 normal and 82 dry eye patients. We have observed that the dry eye patients have a fast cooling of the ocular surface temperature than the normal control group. We have developed a simplified algorithm for calculating the temperature decay constant of the ocular surface for discriminating between normal and dry eye. This study shows the diagnostic of dry eye syndrome by the infrared thermal imager system has reached a sensitivity of 79.3%, a specificity of 75%, and the area under the ROC curve 0.841. The infrared thermal imager system has a great potential to be developed for dry eye screening with the advantages of non-contact, fast, and convenient implementation.

  1. Investigating the Temporal Patterns within and between Intrinsic Connectivity Networks under Eyes-Open and Eyes-Closed Resting States: A Dynamical Functional Connectivity Study Based on Phase Synchronization

    PubMed Central

    Wang, Xun-Heng; Li, Lihua; Xu, Tao; Ding, Zhongxiang

    2015-01-01

    The brain active patterns were organized differently under resting states of eyes open (EO) and eyes closed (EC). The altered voxel-wise and regional-wise resting state active patterns under EO/EC were found by static analysis. More importantly, dynamical spontaneous functional connectivity has been observed in the resting brain. To the best of our knowledge, the dynamical mechanisms of intrinsic connectivity networks (ICNs) under EO/EC remain largely unexplored. The goals of this paper were twofold: 1) investigating the dynamical intra-ICN and inter-ICN temporal patterns during resting state; 2) analyzing the altered dynamical temporal patterns of ICNs under EO/EC. To this end, a cohort of healthy subjects with scan conditions of EO/EC were recruited from 1000 Functional Connectomes Project. Through Hilbert transform, time-varying phase synchronization (PS) was applied to evaluate the inter-ICN synchrony. Meanwhile, time-varying amplitude was analyzed as dynamical intra-ICN temporal patterns. The results found six micro-states of inter-ICN synchrony. The medial visual network (MVN) showed decreased intra-ICN amplitude during EC relative to EO. The sensory-motor network (SMN) and auditory network (AN) exhibited enhanced intra-ICN amplitude during EC relative to EO. Altered inter-ICN PS was found between certain ICNs. Particularly, the SMN and AN exhibited enhanced PS to other ICNs during EC relative to EO. In addition, the intra-ICN amplitude might influence the inter-ICN synchrony. Moreover, default mode network (DMN) might play an important role in information processing during EO/EC. Together, the dynamical temporal patterns within and between ICNs were altered during different scan conditions of EO/EC. Overall, the dynamical intra-ICN and inter-ICN temporal patterns could benefit resting state fMRI-related research, and could be potential biomarkers for human functional connectome. PMID:26469182

  2. Design and Implementation of Real-Time Off-Grid Detection Tool Based on FNET/GridEye

    SciTech Connect

    Guo, Jiahui; Zhang, Ye; Liu, Yilu; Young II, Marcus Aaron; Irminger, Philip; Dimitrovski, Aleksandar D; Willging, Patrick

    2014-01-01

    Real-time situational awareness tools are of critical importance to power system operators, especially during emergencies. The availability of electric power has become a linchpin of most post disaster response efforts as it is the primary dependency for public and private sector services, as well as individuals. Knowledge of the scope and extent of facilities impacted, as well as the duration of their dependence on backup power, enables emergency response officials to plan for contingencies and provide better overall response. Based on real-time data acquired by Frequency Disturbance Recorders (FDRs) deployed in the North American power grid, a real-time detection method is proposed. This method monitors critical electrical loads and detects the transition of these loads from an on-grid state, where the loads are fed by the power grid to an off-grid state, where the loads are fed by an Uninterrupted Power Supply (UPS) or a backup generation system. The details of the proposed detection algorithm are presented, and some case studies and off-grid detection scenarios are also provided to verify the effectiveness and robustness. Meanwhile, the algorithm has already been implemented based on the Grid Solutions Framework (GSF) and has effectively detected several off-grid situations.

  3. A bare-eye based one-step signal amplified semiquantitative immunochromatographic assay for the detection of imidacloprid in Chinese cabbage samples.

    PubMed

    Fang, Qingkui; Wang, Limin; Cheng, Qi; Cai, Jia; Wang, Yulong; Yang, Mingming; Hua, Xiude; Liu, Fengquan

    2015-06-30

    A novel bare-eye based one-step signal amplified semi-quantitative immunochromatographic assay (SAS-ICA) was developed for detection of the pesticide imidacloprid. This method was based on competitive immunoreactions. Signal amplification was achieved by dual labeling of the test lines (TLs) on the strip using high affinity nanogold-biotinylated anti-imidacloprid mAb (BAb) and nanogold-streptavidin (Sa) probes. The relative color intensities of three TLs (TL-I, TL-II and TL-III) on a nitrocellulose (NC) membrane were used for direct visual analysis of the SAS-ICA strips, and could be used for semi-quantitation of analyte concentrations by observing what TLs disappeared in the amplification zone. Under optimized conditions, the following imidacloprid concentration ranges would be detected by visual examination of the SAS-ICA strip: 0-5ngmL(-1) (negative samples), and 5-25ngmL(-1), 25-250ngmL(-1), 250-1000ngmL(-1) and >1000ngmL(-1) (positive samples). The sensitivity (the visual detection limit (VDL) of TL-III) and semi-quantitative analytical capacity (when TL-III disappeared completely) of the SAS-ICA strip were 10-fold and 160-fold higher than those of traditional ICA, respectively. The developed SAS-ICA strip was applied to the analysis of spiked and authentic contaminated Chinese cabbage samples in the laboratory and under field conditions, and the results were validated by high-performance liquid chromatography (HPLC). This process could be adopted as a potential generous technique for all ICA-based detection methods. PMID:26041523

  4. New pediatric vision screener employing polarization-modulated, retinal-birefringence-scanning-based strabismus detection and bull's eye focus detection with an improved target system: opto-mechanical design and operation

    NASA Astrophysics Data System (ADS)

    Irsch, Kristina; Gramatikov, Boris I.; Wu, Yi-Kai; Guyton, David L.

    2014-06-01

    Amblyopia ("lazy eye") is a major public health problem, caused by misalignment of the eyes (strabismus) or defocus. If detected early in childhood, there is an excellent response to therapy, yet most children are detected too late to be treated effectively. Commercially available vision screening devices that test for amblyopia's primary causes can detect strabismus only indirectly and inaccurately via assessment of the positions of external light reflections from the cornea, but they cannot detect the anatomical feature of the eyes where fixation actually occurs (the fovea). Our laboratory has been developing technology to detect true foveal fixation, by exploiting the birefringence of the uniquely arranged Henle fibers delineating the fovea using retinal birefringence scanning (RBS), and we recently described a polarization-modulated approach to RBS that enables entirely direct and reliable detection of true foveal fixation, with greatly enhanced signal-to-noise ratio and essentially independent of corneal birefringence (a confounding variable with all polarization-sensitive ophthalmic technology). Here, we describe the design and operation of a new pediatric vision screener that employs polarization-modulated, RBS-based strabismus detection and bull's eye focus detection with an improved target system, and demonstrate the feasibility of this new approach.

  5. The injured eye

    PubMed Central

    Scott, Robert

    2011-01-01

    Eye injuries come at a high cost to society and are avoidable. Ocular blast injuries can be primary, from the blast wave itself; secondary, from fragments carried by the blast wind; tertiary; due to structural collapse or being thrown against a fixed object; or quaternary, from burns and indirect injuries. Ballistic eye protection significantly reduces the incidence of eye injuries and should be encouraged from an early stage in Military training. Management of an injured eye requires meticulous history taking, evaluation of vision that measures the acuity and if there is a relative pupillary defect as well as careful inspection of the eyes, under anaesthetic if necessary. A lateral canthotomy with cantholysis should be performed immediately if there is a sight-threatening retrobulbar haemorrhage. Systemic antibiotics should be prescribed if there is a suspected penetrating or perforating injury. A ruptured globe should be protected by an eye shield. Primary repair of ruptured globes should be performed in a timely fashion. Secondary procedures will often be required at a later date to achieve sight preservation. A poor initial visual acuity is not a guarantee of a poor final result. The final result can be predicted after approximately 3–4 weeks. Future research in eye injuries attempts to reduce scarring and neuronal damage as well as to promote photoreceptor rescue, using post-transcriptional inhibition of cell death pathways and vaccination to promote neural recovery. Where the sight has been lost sensory substitution of a picture from a spectacle mounted video camera to the touch receptors of the tongue can be used to achieve appreciation of the outside world. PMID:21149360

  6. A bird's eye view of anisatin induced convulsive seizures in brain by a (1)H NMR based metabolic approach.

    PubMed

    Wei, Dan-Dan; Ge-Dong; Guo, Ping-Ping; Wang, Jun-Song; Li, Ming-Hui; Yang, Ming-Hua; Kong, Ling-Yi

    2014-11-01

    Anisatin is the main convulsant component in plants of the genus Illicium, many of which are important spices or folk medicines. The neurotoxicity of anisatin has been widely investigated, mainly focusing on its action on the γ-amino butyrate (GABA) system; however, little is known about the metabolic alterations that it causes. In this study, a NMR-based metabolomic approach was performed on the extracts of cortexes and cerebellums of mice administered with anisatin to explore the metabolic events associated with its intoxication. Orthogonal partial least squares-discriminant analysis (OPLS-DA) revealed many differential metabolites that indicated metabolic disturbance in neurotransmission and neuromodulation (GABA, glutamate, glutamine, and taurine), stress of reactive oxygen species (ROS) (ascorbate, phosphatidylcholine, choline, and ethanolamine), energy metabolism (NAD(+)i.e., nicotinamide-adenine dinucleotide, lactate, citrate, fumarate, creatine/phosphocreatine, and creatinine), amino acid metabolism (leucine, isoleucine, valine, phenylalanine, tyrosine, tryptophan, alanine, threonine, and glycine) and nucleic acid metabolism (NAD(+), nicotinamide/niacinamide, adenosine, and guanosine). This pilot metabolomic study on anisatin intoxication should help to develop a holistic view of convulsive seizures induced by anisatin, and provide a better understanding of the mechanisms. PMID:25133938

  7. Synthesis and studies of selective chemosensor for naked-eye detection of anions and cations based on a new Schiff-base derivative.

    PubMed

    Orojloo, Masoumeh; Amani, Saeid

    2016-10-01

    A new chromogenic receptor, 4-((2,4-dichlorophenyl)diazenyl)-2-(3-hydroxypropylimino) methyl)phenol, has been designed and synthesized for quantitative and low-cost detection of various biological anions and cations. The dye was characterized by elemental analyses, infrared, UV-visible spectroscopy, and NMR spectroscopy. Upon the addition of F(-) and H2PO4(-) to the solution of chemosensor in DMSO, the dramatic naked eye detectable color changes were observed from yellow to red and orange with a limit of detection (LOD) of 1.66×10(-6)mol. L(-1) and 1.24×10(-6)mol. L(-1) at room temperature, respectively. The chemosensor showed visual changes towards cations, such as Al(3+), Cu(2+), Fe(3+), and Cr(3+), in DMSO/water (9:1). The detection limit of receptor L for the analysis of Al(3+) ion was calculated to be 3.02×10(-6)mol. L(-1). The anion recognition property of the receptor via proton transfer was monitored by UV-visible titration and (1)HNMR spectroscopy. The binding constant (Ka) and stoichiometry of the host-guest complexes formed were determined by the Benesi-Hildebrand (B-H) plot and Job's method, respectively. PMID:27474311

  8. Eye movements and information geometry.

    PubMed

    Lenz, Reiner

    2016-08-01

    The human visual system uses eye movements to gather visual information. They act as visual scanning processes and can roughly be divided into two different types: small movements around fixation points and larger movements between fixation points. The processes are often modeled as random walks, and recent models based on heavy tail distributions, also known as Levý flights, have been used in these investigations. In contrast to these approaches we do not model the stochastic processes, but we will show that the step lengths of the movements between fixation points follow generalized Pareto distributions (GPDs). We will use general arguments from the theory of extreme value statistics to motivate the usage of the GPD and show empirically that the GPDs provide good fits for measured eye tracking data. In the framework of information geometry the GPDs with a common threshold form a two-dimensional Riemann manifold with the Fisher information matrix as a metric. We compute the Fisher information matrix for the GPDs and introduce a feature vector describing a GPD by its parameters and different geometrical properties of its Fisher information matrix. In our statistical analysis we use eye tracker measurements in a database with 15 observers viewing 1003 images under free-viewing conditions. We use Matlab functions with their standard parameter settings and show that a naive Bayes classifier using the eigenvalues of the Fisher information matrix provides a high classification rate identifying the 15 observers in the database. PMID:27505658

  9. Undiagnosed hypertension in a rural district in Bangladesh: The Bangladesh Population-based Diabetes and Eye Study (BPDES).

    PubMed

    Islam, F M A; Bhuiyan, A; Chakrabarti, R; Rahman, M A; Kanagasingam, Y; Hiller, J E

    2016-04-01

    Hypertension is mainly asymptomatic and remains undiagnosed until the disease progresses. The objective of the study was to determine the prevalence of and risk factors for hypertension in rural Bangladesh. Using a population-based cluster random sampling strategy, 3096 adults aged ⩾30 years were recruited from a rural district in Bangladesh. Data collected included two blood pressure (BP) measurements, fasting blood glucose, socio-demographic and anthropometric measurements. Hypertension was defined as systolic BP (SBP) ⩾140 mm Hg or diastolic BP (DBP) ⩾90 mm Hg or self-reported diagnosed hypertension. Logistic regression techniques were used for data analyses. The crude prevalence of hypertension was 40% (95% confidence interval (CI) 38-42%) of which 82% were previously undiagnosed. People from lower socio-economic status (SES) had a significantly higher percentage of undiagnosed hypertension compared with people with higher SES (P<0.001). There was no significant gender difference in severity of hypertension. Males with higher education level compared with no education had a higher prevalence of hypertension (odds ratio 2.34, 95% CI 1.49-3.69). Older age and waist circumference in both genders, and diabetes, lack of physical activity in females were found to be associated with higher prevalence of hypertension. Our research suggests the prevalence of undiagnosed hypertension was higher in the rural area in Bangladesh than that reported from the rural area in neighbouring India and China. Lower SES was associated with a higher risk of undiagnosed hypertension. Public health programs at the grass-roots level must emphasise the provision of primary care and preventive services in managing this non-communicable disease. PMID:26108363

  10. Beam’s-eye-view dosimetrics (BEVD) guided rotational station parameter optimized radiation therapy (SPORT) planning based on reweighted total-variation minimization.

    PubMed

    Kim, Hojin; Li, Ruijiang; Lee, Rena; Xing, Lei

    2015-03-01

    Conventional VMAT optimizes aperture shapes and weights at uniformly sampled stations, which is a generalization of the concept of a control point. Recently, rotational station parameter optimized radiation therapy (SPORT) has been proposed to improve the plan quality by inserting beams to the regions that demand additional intensity modulations, thus formulating nonuniform beam sampling. This work presents a new rotational SPORT planning strategy based on reweighted total-variation (TV) minimization (min.), using beam’s-eye-view dosimetrics (BEVD) guided beam selection. The convex programming based reweighted TV min. assures the simplified fluence-map, which facilitates single-aperture selection at each station for single-arc delivery. For the rotational arc treatment planning and non-uniform beam angle setting, the mathematical model needs to be modified by additional penalty term describing the fluence-map similarity and by determination of appropriate angular weighting factors. The proposed algorithm with additional penalty term is capable of achieving more efficient and deliverable plans adaptive to the conventional VMAT and SPORT planning schemes by reducing the dose delivery time about 5 to 10 s in three clinical cases (one prostate and two head-and-neck (HN) cases with a single and multiple targets). The BEVD guided beam selection provides effective and yet easy calculating methodology to select angles for denser, non-uniform angular sampling in SPORT planning. Our BEVD guided SPORT treatment schemes improve the dose sparing to femoral heads in the prostate and brainstem, parotid glands and oral cavity in the two HN cases, where the mean dose reduction of those organs ranges from 0.5 to 2.5 Gy. Also, it increases the conformation number assessing the dose conformity to the target from 0.84, 0.75 and 0.74 to 0.86, 0.79 and 0.80 in the prostate and two HN cases, while preserving the delivery efficiency, relative to conventional single-arc VMAT plans. PMID

  11. COMPU-EYE: a high resolution computational compound eye.

    PubMed

    Lee, Woong-Bi; Jang, Hwanchol; Park, Sangjun; Song, Young Min; Lee, Heung-No

    2016-02-01

    In nature, the compound eyes of arthropods have evolved towards a wide field of view (FOV), infinite depth of field and fast motion detection. However, compound eyes have inferior resolution when compared with the camera-type eyes of vertebrates, owing to inherent structural constraints such as the optical performance and the number of ommatidia. For resolution improvements, in this paper, we propose COMPUtational compound EYE (COMPU-EYE), a new design that increases acceptance angles and uses a modern digital signal processing (DSP) technique. We demonstrate that the proposed COMPU-EYE provides at least a four-fold improvement in resolution. PMID:26906778

  12. Multiple states and joint objects particle filter for eye tracking

    NASA Astrophysics Data System (ADS)

    Xiong, Jin; Jiang, Zhaohui; Liu, Junwei; Feng, Huanqing

    2007-11-01

    Recent works have proven that the particle filter is a powerful tracking technique for non-linear and non-Gaussian estimation problem. This paper presents an extension algorithm based on the color-based particle filter framework, which is applicable for complex eye tracking because of two main innovations. Firstly, an employment of an extra discrete-value variable and its associated transition probability matrix (TPM) makes it feasible in tracking multiple states of the eye during blinking. Secondly, the joint-object thought used in state vector eliminates the distraction from eyes to each other. The experimental results illustrate that the proposed algorithm is efficient for eye tracking.

  13. Photorefraction of the Eye

    NASA Astrophysics Data System (ADS)

    Colicchia, Giuseppe; Wiesner, Hartmut; Zollman, Dean

    2015-02-01

    Photorefraction is a method to easily estimate the refractive state of the eye. The principle of photorefraction involves projecting light into the eye during flash photography and then examining the paths of light that emerge from the pupil after scattering on the back portion of the interior of the eyeball (fundus). We will explain the optical principles underlying the method for eccentric photorefraction and describe how students can perform it using current digital cameras. Our purpose is not to diagnose refractive errors reliably, but to use devices popular among young people that, in combination with an important ophthalmic context, may be successful in improving students' interest for learning optical concepts.

  14. Glaucoma: Eye-to-Eye with Dr. Rachel Bishop

    MedlinePlus

    ... of this page please turn JavaScript on. Feature: Glaucoma Eye-to-Eye with Dr. Rachel Bishop Past ... nerves are pale and cupped—signs of advanced glaucoma. Yet the patient wasn't aware of any ...

  15. Eye evolution: two eyes can be better than one.

    PubMed

    Foster, Kenneth W

    2009-03-10

    The development of our eyes is owed in part to ancestral structures which functioned in phototaxis. With the origin of bilateral annelid larva, two eyes co-evolved with neurons to improve phototaxis performance. PMID:19278637

  16. Design of a computer game using an eye-tracking device for eye's activity rehabilitation

    NASA Astrophysics Data System (ADS)

    Lin, Chern-Sheng; Huan, Chia-Chin; Chan, Chao-Ning; Yeh, Mau-Shiun; Chiu, Chuang-Chien

    2004-07-01

    An eye mouse interface that can be used to operate a computer using the movement of the eyes is described. We developed this eye-tracking system for eye motion disability rehabilitation. When the user watches the screen of a computer, a charge-coupled device will catch images of the user's eye and transmit it to the computer. A program, based on a new cross-line tracking and stabilizing algorithm, will locate the center point of the pupil in the images. The calibration factors and energy factors are designed for coordinate mapping and blink functions. After the system transfers the coordinates of pupil center in the images to the display coordinate, it will determine the point at which the user gazed on the display, then transfer that location to the game subroutine program. We used this eye-tracking system as a joystick to play a game with an application program in a multimedia environment. The experimental results verify the feasibility and validity of this eye-game system and the rehabilitation effects for the user's visual movement.

  17. Comparison of eye imaging pattern recognition using neural network

    NASA Astrophysics Data System (ADS)

    Bukhari, W. M.; Syed A., M.; Nasir, M. N. M.; Sulaima, M. F.; Yahaya, M. S.

    2015-05-01

    The beauty of eye recognition system that it is used in automatic identifying and verifies a human weather from digital images or video source. There are various behaviors of the eye such as the color of the iris, size of pupil and shape of the eye. This study represents the analysis, design and implementation of a system for recognition of eye imaging. All the eye images that had been captured from the webcam in RGB format must through several techniques before it can be input for the pattern and recognition processes. The result shows that the final value of weight and bias after complete training 6 eye images for one subject is memorized by the neural network system and be the reference value of the weight and bias for the testing part. The target classifies to 5 different types for 5 subjects. The eye images can recognize the subject based on the target that had been set earlier during the training process. When the values between new eye image and the eye image in the database are almost equal, it is considered the eye image is matched.

  18. Prevalence of skeletal and eye malformations in frogs from north-central United States: estimations based on collections from randomly selected sites

    USGS Publications Warehouse

    Schoff, P.K.; Johnson, C.M.; Schotthoefer, A.M.; Murphy, J.E.; Lieske, C.; Cole, R.A.; Johnson, L.B.; Beasley, V.R.

    2003-01-01

    Skeletal malformation rates for several frog species were determined in a set of randomly selected wetlands in the north-central USA over three consecutive years. In 1998, 62 sites yielded 389 metamorphic frogs, nine (2.3%) of which had skeletal or eye malformations. A subset of the original sites was surveyed in the following 2 yr. In 1999, 1,085 metamorphic frogs were collected from 36 sites and 17 (1.6%) had skeletal or eye malformations, while in 2000, examination of 1,131 metamorphs yielded 16 (1.4%) with skeletal or eye malformations. Hindlimb malformations predominated in all three years, but other abnormalities, involving forelimb, eye, and pelvis were also found. Northern leopard frogs (Rana pipiens) constituted the majority of collected metamorphs as well as most of the malformed specimens. However, malformations were also noted in mink frogs (R. septentrionalis), wood frogs (R. sylvatica), and gray tree frogs (Hyla spp.). The malformed specimens were found in clustered sites in all three years but the cluster locations were not the same in any year. The malformation rates reported here are higher than the 0.3% rate determined for metamorphic frogs collected from similar sites in Minnesota in the 1960s, and thus, appear to represent an elevation of an earlier baseline malformation rate.

  19. Pursuit Eye Movements

    NASA Technical Reports Server (NTRS)

    Krauzlis, Rich; Stone, Leland; Null, Cynthia H. (Technical Monitor)

    1998-01-01

    When viewing objects, primates use a combination of saccadic and pursuit eye movements to stabilize the retinal image of the object of regard within the high-acuity region near the fovea. Although these movements involve widespread regions of the nervous system, they mix seamlessly in normal behavior. Saccades are discrete movements that quickly direct the eyes toward a visual target, thereby translating the image of the target from an eccentric retinal location to the fovea. In contrast, pursuit is a continuous movement that slowly rotates the eyes to compensate for the motion of the visual target, minimizing the blur that can compromise visual acuity. While other mammalian species can generate smooth optokinetic eye movements - which track the motion of the entire visual surround - only primates can smoothly pursue a single small element within a complex visual scene, regardless of the motion elsewhere on the retina. This ability likely reflects the greater ability of primates to segment the visual scene, to identify individual visual objects, and to select a target of interest.

  20. Through Our Eyes

    ERIC Educational Resources Information Center

    Narva, Sara

    2009-01-01

    Through Our Eyes was a multimedia performance created in collaboration with the author's five modern dance students. Through video, sound, and dance, the piece shows some ways race has affected their lives. The author did not set out at the beginning of the semester to make this project in her dance class. It was born out of a hard conversation,…

  1. The Eyes Have It.

    ERIC Educational Resources Information Center

    Walsh, Janet

    1982-01-01

    Discusses the health hazards of working with the visual display systems of computers, in particular the eye problems associated with long-term use of video display terminals. Excerpts from and ordering information for the National Institute for Occupational Safety and Health report on such hazards are included. (JJD)

  2. The Eyes Have It

    NASA Technical Reports Server (NTRS)

    1999-01-01

    NASA'S Ames Research Center contracted with SRI international to contract a device that would be able to anticipate, track, and monitor involuntary ocular movement horizontally, vertically, and with respect to depth-of-field. This development helped research institutions to understand the eye. The Eyetracker, manufactured and distributed by Forward Optical Technologies, Inc. is now used in the clinical/medical field.

  3. Through Students' Eyes.

    ERIC Educational Resources Information Center

    McLean-Donaldson, Karen B.

    1994-01-01

    Identifies how students perceive racism and its effects on student learning and whether antiracist/multicultural arts (ARMA) curricula can empower students to address racism in schools. Results show racism, through students' eyes, damages learning, attitudes, and behavior. ARMA positively effected students' ability to confront racism within their…

  4. Administering Eye Medications.

    ERIC Educational Resources Information Center

    Morris, Sara; Michael, Nancy, Ed.

    This module on administering eye medications is intended for use in inservice or continuing education programs for persons who administer medications in long-term care facilities. Instructor information, including teaching suggestions, and a listing of recommended audiovisual materials and their sources appear first. A brief discussion follows of…

  5. Red or uncomfortable eye.

    PubMed Central

    Davey, C.; Hurwitz, B.

    1992-01-01

    1. A red, uncomfortable eye may be accompanied by other symptoms such as blurred, decreased, or double vision, haloes, photophobia, pain or discharge. 2. A careful history and brief systematic examination will sort out most problems. 3. Examine eyelids, the conjunctivae and corneas. Checking visual acuity is often important. 4. The most common underlying causes can usually be managed within general practice, though a few patients will require urgent eye assessment, or routine referral to ophthalmic outpatients. 5. The following are typical eye problems which require urgent referral: History of pain as opposed to discomfort, Trauma including foreign bodies, chemicals and suspected penetrating injury, Unexplained drop in visual acuity of two lines or more in a painful eye. Specific conditions: preseptal cellulitis, herpes simplex ulcer, scleritis, orbital cellulitis, herpes zoster, bacterial corneal ulcer, dacryocystitis. 6. The following are typical problems which may require routine referral: Persistence of the problem not relieved by simple measures, Recurrent disorders of uncertain diagnosis, Eyelid swelling such as chalazion, cysts, basal cell carcinoma, Gradual loss of vision, for example cataract, macular degeneration. PMID:1345157

  6. Diabetes - eye care

    MedlinePlus

    ... blurred vision is caused by having too much sugar and water in the lens of the eye, which is in front of the retina. Control your blood pressure . Blood pressure less than 130/80 is a ... sugar - self-care Diabetes - preventing heart attack and stroke ...

  7. Eye of the Beholder

    ERIC Educational Resources Information Center

    Rogers, Michael

    2010-01-01

    Art, like beauty, as the adage goes, is in the eye of the beholder. Art also is a living, breathing thing that evolves over time, so what is considered "art" is ever changing--how many of the great artists whose works today sell for fortunes were failures during their lifetime? The 20th century unknowingly gave birth to new variations of art that…

  8. Eyes for Learning

    ERIC Educational Resources Information Center

    Orfield, Antonia

    2008-01-01

    Vision is the dominant sense, and the eyes are connected with almost every other part of the brain. If the vision system is poorly developed, children trying to learn suffer. Without good up close vision, students are handicapped even if no one knows or suspects it--they may not even know it themselves. Students do not know that the way they see…

  9. Common eye emergencies.

    PubMed

    Gelston, Christopher D

    2013-10-15

    Ocular emergencies such as retinal detachments, mechanical globe injuries, and chemical injuries can cause permanent vision loss if they are not recognized and treated promptly. Family physicians should be familiar with the signs and symptoms associated with each condition, and be able to perform a basic eye examination to assess the situation. The assessment includes measurement of visual acuity, pupillary examination, visual field testing, slit lamp or penlight examination of the anterior segment of the eye, and direct funduscopic examination. Patients with symptomatic floaters and flashing lights require a dilated fundoscopic examination and prompt referral to an ophthalmologist for evaluation of a retinal tear or detachment. A globe laceration or rupture should be suspected in patients with a recent history of trauma from a blunt or penetrating object. Prophylactic oral antibiotics can be administered after a globe injury to prevent endophthalmitis, and the eye should be covered with a metal shield until evaluation by an ophthalmologist. Chemical injuries require immediate irrigation of the eye to neutralize the pH of the ocular surface. PMID:24364572

  10. Simple Solutions for Dry Eye

    MedlinePlus

    ... are more concentrated in the tear film of dry eye patients. In hot weather, sleep with the windows shut and keep cool with air conditioning. • Dry eye patients often develop or aggravate allergies. An ...

  11. Infographic on the Aging Eye

    MedlinePlus

    ... retina. Dry eye Low vision Damage to the optic nerve. Eyes do not make enough tears. Difficulty ... retina that can be seen through undilated pupil. OPTIC NERVE RAY OF LIGHT PUPIL RETINA Portion of ...

  12. Recognizing and Treating Eye Injuries

    MedlinePlus

    ... and seek medical attention. In case of a chemical burn to the eye: Immediately flush the eye ... Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms of Service For ...

  13. Medicare Benefits and Your Eyes

    MedlinePlus

    ... Eye Health Report Reports and External Resources The Cost of Vision Problems The Future of Vision Vision Problems in the U.S. Healthy Eyes Education Series Online Training and Certification Patient Education Materials ...

  14. Patterns of uveitis at the Apex Institute for Eye Care in India: Results from a prospectively enrolled patient data base (2011-2013).

    PubMed

    Venkatesh, Pradeep; Gogia, Varun; Shah, Bhavin; Gupta, Shikha; Sagar, Pradeep; Garg, Satpal

    2016-06-01

    The purpose of the study was to identify the clinical and etiological profile of uveitis at the apex institute for eye care in India. This is a prospective, prevalence study. 980 consecutive patients with uveitis referred to uvea clinic, Dr. RP Centre for Ophthalmic Sciences (Ophthalmology division, All India Institute of Medical Sciences). Demographic data of each patient were noted and a thorough ocular examination including slit lamp examination and dilated fundus evaluation was carried out. OCT and fluorescein angiography were undertaken whenever indicated. Uveitis was classified based on the anatomic location of inflammation (IUSG classification). Relevant serological and radiological investigations were obtained based on systemic symptomatology, and if the uveitis was recurrent (even in the absence of systemic symptoms). The presence of a systemic disease was confirmed by obtaining an internist consultation. The main outcome measures include pattern of uveitis according to anatomical classification and the etiology. Out of 980 patients with uveitis, 413 (42.14 %) patients had anterior uveitis, 131 (13.36 %) had intermediate uveitis, 165 (16.83 %) had posterior uveitis, 91 (9.2 %) had panuveitis, 47 (4.7 %) had retinal vasculitis, 22 (2.24 %) had scleritis, 17 (1.7 %) had masquerade syndromes, 8 (0.8 %) had keratouveitis, 22 (2.24 %) had sclerokeratouveitis, 19 (1.9 %) had endophthalmitis and 45 (4.5 %) had other causes of inflammation including trauma and intraocular surgery. Out of all uveitic patients definite etiological correlation could be made out in 225 (23 %) patients; thus 77 % were categorised as idiopathic. Only 9 % of all patients were found to have uveitis with an infectious etiology. Amongst infectious causes of uveitis tuberculosis was the leading cause, accounting for sixty percent of all infectious uveitis (approximately 5 % of overall uveitis). Non-infectious uveitis etiology accounted for more than 90 % of all cases with

  15. Beam’s-eye-view dosimetrics (BEVD) guided rotational station parameter optimized radiation therapy (SPORT) planning based on reweighted total-variation minimization

    NASA Astrophysics Data System (ADS)

    Kim, Hojin; Li, Ruijiang; Lee, Rena; Xing, Lei

    2015-03-01

    Conventional VMAT optimizes aperture shapes and weights at uniformly sampled stations, which is a generalization of the concept of a control point. Recently, rotational station parameter optimized radiation therapy (SPORT) has been proposed to improve the plan quality by inserting beams to the regions that demand additional intensity modulations, thus formulating non-uniform beam sampling. This work presents a new rotational SPORT planning strategy based on reweighted total-variation (TV) minimization (min.), using beam’s-eye-view dosimetrics (BEVD) guided beam selection. The convex programming based reweighted TV min. assures the simplified fluence-map, which facilitates single-aperture selection at each station for single-arc delivery. For the rotational arc treatment planning and non-uniform beam angle setting, the mathematical model needs to be modified by additional penalty term describing the fluence-map similarity and by determination of appropriate angular weighting factors. The proposed algorithm with additional penalty term is capable of achieving more efficient and deliverable plans adaptive to the conventional VMAT and SPORT planning schemes by reducing the dose delivery time about 5 to 10 s in three clinical cases (one prostate and two head-and-neck (HN) cases with a single and multiple targets). The BEVD guided beam selection provides effective and yet easy calculating methodology to select angles for denser, non-uniform angular sampling in SPORT planning. Our BEVD guided SPORT treatment schemes improve the dose sparing to femoral heads in the prostate and brainstem, parotid glands and oral cavity in the two HN cases, where the mean dose reduction of those organs ranges from 0.5 to 2.5 Gy. Also, it increases the conformation number assessing the dose conformity to the target from 0.84, 0.75 and 0.74 to 0.86, 0.79 and 0.80 in the prostate and two HN cases, while preserving the delivery efficiency, relative to conventional single-arc VMAT plans.

  16. Combining EEG and eye tracking: identification, characterization, and correction of eye movement artifacts in electroencephalographic data.

    PubMed

    Plöchl, Michael; Ossandón, José P; König, Peter

    2012-01-01

    Eye movements introduce large artifacts to electroencephalographic recordings (EEG) and thus render data analysis difficult or even impossible. Trials contaminated by eye movement and blink artifacts have to be discarded, hence in standard EEG-paradigms subjects are required to fixate on the screen. To overcome this restriction, several correction methods including regression and blind source separation have been proposed. Yet, there is no automated standard procedure established. By simultaneously recording eye movements and 64-channel-EEG during a guided eye movement paradigm, we investigate and review the properties of eye movement artifacts, including corneo-retinal dipole changes, saccadic spike potentials and eyelid artifacts, and study their interrelations during different types of eye- and eyelid movements. In concordance with earlier studies our results confirm that these artifacts arise from different independent sources and that depending on electrode site, gaze direction, and choice of reference these sources contribute differently to the measured signal. We assess the respective implications for artifact correction methods and therefore compare the performance of two prominent approaches, namely linear regression and independent component analysis (ICA). We show and discuss that due to the independence of eye artifact sources, regression-based correction methods inevitably over- or under-correct individual artifact components, while ICA is in principle suited to address such mixtures of different types of artifacts. Finally, we propose an algorithm, which uses eye tracker information to objectively identify eye-artifact related ICA-components (ICs) in an automated manner. In the data presented here, the algorithm performed very similar to human experts when those were given both, the topographies of the ICs and their respective activations in a large amount of trials. Moreover it performed more reliable and almost twice as effective than human experts

  17. The impact of speckle on the measurement of eye aberrations

    NASA Astrophysics Data System (ADS)

    Goncharov, Alexey S.; Iroshnikov, Nikita G.; Larichev, Andrey V.; Nikolaev, Ilia P.

    2015-12-01

    We report the results of modeling the speckle structure of an optical field, which arises due to scattering of laser radiation at the retina of the human eye. The presence of such a speckle structure in the scattered radiation leaving the eye affects the accuracy of wavefront measurements aimed at determining the overall aberrations of the eye. We compared two methods for suppressing such speckle structures based on spatial and spectral averaging of a variety of speckle field realizations. The results of both theoretical calculations and numerical simulations appeared to be in a good agreement with experimental data obtained with the eye model and in vivo.

  18. Experiments on a Model Eye

    ERIC Educational Resources Information Center

    Arell, Antti; Kolari, Samuli

    1978-01-01

    Explains a laboratory experiment dealing with the optical features of the human eye. Shows how to measure the magnification of the retina and the refractive anomaly of the eye could be used to measure the refractive power of the observer's eye. (GA)

  19. How the Human Eye Focuses.

    ERIC Educational Resources Information Center

    Koretz, Jane F.; Handelman, George H.

    1988-01-01

    Describes the decline in people's ability to focus their eyes as their age increases. Discusses probable causes of this effect including changes in the eye's geometry and biochemistry. Diagrammatically illustrates age related changes in the lens of the human eye. (CW)

  20. Eye Protection in Kansas Schools.

    ERIC Educational Resources Information Center

    Hay, Kenneth M.; And Others

    A law passed by a state legislature requires that students in industrial arts shops and science laboratories must wear eye protective devices. Explanatory material presents the text of the bill and guidelines for implementation, including--(1) types of eye hazards, (2) types of protective devices, (3) administrating eye safety equipment, (4)…

  1. Reconstructing the eyes of Urbilateria.

    PubMed Central

    Arendt, D; Wittbrodt, J

    2001-01-01

    The shared roles of Pax6 and Six homologues in the eye development of various bilaterians suggest that Urbilateria, the common ancestors of all Bilateria, already possessed some simple form of eyes. Here, we re-address the homology of bilaterian cerebral eyes at the level of eye anatomy, of eye-constituting cell types and of phototransductory molecules. The most widespread eye type found in Bilateria are the larval pigment-cup eyes located to the left and right of the apical organ in primary, ciliary larvae of Protostomia and Deuterostomia. They can be as simple as comprising a single pigment cell and a single photoreceptor cell in inverse orientation. Another more elaborate type of cerebral pigment-cup eyes with an everse arrangement of photoreceptor cells is found in adult Protostomia. Both inverse larval and everse adult eyes employ rhabdomeric photoreceptor cells and thus differ from the chordate cerebral eyes with ciliary photoreceptors. This is highly significant because on the molecular level we find that for phototransduction rhabdomeric versus ciliary photoreceptor cells employ divergent rhodopsins and non-orthologous G-proteins, rhodopsin kinases and arrestins. Our comparison supports homology of cerebral eyes in Protostomia; it challenges, however, homology of chordate and non-chordate cerebral eyes that employ photoreceptor cells with non-orthologous phototransductory cascades. PMID:11604122

  2. LIMNOLOGICAL OPTOMETRY: EXAMINING EARTH'S EYE

    EPA Science Inventory

    In Thoreau's Walden, a lake is described as the landscape's most expressive feature and the earth's eye. Collectively, scientists are charged by society to assess, monitor, and remedy maladies of earth's eye in the same way optometrists maintain the health of the human eye. This ...

  3. Application of 3-Dimensional Printing Technology to Construct an Eye Model for Fundus Viewing Study

    PubMed Central

    Li, Xinhua; Gao, Zhishan; Yuan, Dongqing; Liu, Qinghuai

    2014-01-01

    Objective To construct a life-sized eye model using the three-dimensional (3D) printing technology for fundus viewing study of the viewing system. Methods We devised our schematic model eye based on Navarro's eye and redesigned some parameters because of the change of the corneal material and the implantation of intraocular lenses (IOLs). Optical performance of our schematic model eye was compared with Navarro's schematic eye and other two reported physical model eyes using the ZEMAX optical design software. With computer aided design (CAD) software, we designed the 3D digital model of the main structure of the physical model eye, which was used for three-dimensional (3D) printing. Together with the main printed structure, polymethyl methacrylate(PMMA) aspherical cornea, variable iris, and IOLs were assembled to a physical eye model. Angle scale bars were glued from posterior to periphery of the retina. Then we fabricated other three physical models with different states of ammetropia. Optical parameters of these physical eye models were measured to verify the 3D printing accuracy. Results In on-axis calculations, our schematic model eye possessed similar size of spot diagram compared with Navarro's and Bakaraju's model eye, much smaller than Arianpour's model eye. Moreover, the spherical aberration of our schematic eye was much less than other three model eyes. While in off- axis simulation, it possessed a bit higher coma and similar astigmatism, field curvature and distortion. The MTF curves showed that all the model eyes diminished in resolution with increasing field of view, and the diminished tendency of resolution of our physical eye model was similar to the Navarro's eye. The measured parameters of our eye models with different status of ametropia were in line with the theoretical value. Conclusions The schematic eye model we designed can well simulate the optical performance of the human eye, and the fabricated physical one can be used as a tool in fundus

  4. What Happens After Treatment for Eye Cancer?

    MedlinePlus

    ... having eye cancer What happens after treatment for eye cancer? For many people with eye cancer, treatment ... manage them. Follow-up after treatment of uveal (eye) melanoma Your doctor will most likely want to ...

  5. What Is a Comprehensive Dilated Eye Exam?

    MedlinePlus

    ... su oculista What is a comprehensive dilated eye exam? You may think your eyes are healthy, but ... eye care professional for a comprehensive dilated eye exam is the only way to really be sure. ...

  6. Do Personally Tailored Videos in a Web-Based Physical Activity Intervention Lead to Higher Attention and Recall? – An Eye-Tracking Study

    PubMed Central

    Alley, Stephanie; Jennings, Cally; Persaud, Nayadin; Plotnikoff, Ronald C.; Horsley, Mike; Vandelanotte, Corneel

    2014-01-01

    Over half of the Australian population does not meet physical activity guidelines and has an increased risk of chronic disease. Web-based physical activity interventions have the potential to reach large numbers of the population at low-cost, however issues have been identified with usage and participant retention. Personalized (computer-tailored) physical activity advice delivered through video has the potential to address low engagement, however it is unclear whether it is more effective in engaging participants when compared to text-delivered personalized advice. This study compared the attention and recall outcomes of tailored physical activity advice in video- vs. text-format. Participants (n = 41) were randomly assigned to receive either video- or text-tailored feedback with identical content. Outcome measures included attention to the feedback, measured through advanced eye-tracking technology (TobiiX 120), and recall of the advice, measured through a post intervention interview. Between group ANOVA’s, Mann–Whitney U tests and chi square analyses were applied. Participants in the video-group displayed greater attention to the physical activity feedback in terms of gaze-duration on the feedback (7.7 vs. 3.6 min, p < 001), total fixation-duration on the feedback (6.0 vs. 3.3 min, p < 001), and focusing on feedback (6.8 vs. 3.5 min, p < 001). Despite both groups having the same ability to navigate through the feedback, the video-group completed a significantly (p < 0.001) higher percentage of feedback sections (95%) compared to the text-group (66%). The main messages were recalled in both groups, but many details were forgotten. No significant between group differences were found for message recall. These results suggest that video-tailored feedback leads to greater attention compared to text-tailored feedback. More research is needed to determine how message recall can be improved, and whether video-tailored advice can lead to

  7. 'PET' vs. 'push-pull' induced ICT: a remarkable coumarinyl-appended pyrimidine based naked eye colorimetric and fluorimetric sensor for the detection of Hg2+ ions in aqueous media with test trips.

    PubMed

    Goswami, Shyamaprosad; Das, Avijit Kumar; Maity, Sibaprasad

    2013-12-14

    A novel colorimetric and fluorescent chemosensor based on 7-(diethylamino)-3-(pyrimidin-4-yl)-2H-chromen-2-one (PYC) has been designed and synthesized for the detection of Hg(2+) in the presence of other competing metals in mixed aqueous media. The PYC exhibits naked eye color change from green to red, and the fluorescence color changes from yellowish green to light orange with Hg(2+). It also shows a red shift in wavelength of about 80 nm in absorption spectra. Test strips based on PYC were fabricated, which could act as convenient and efficient Hg(2+) test kits. PMID:24096453

  8. [Conservative treatment of dry eye].

    PubMed

    Hefner, J; Reinshagen, H

    2014-11-01

    The use of topic anti-inflammatory drugs has become very important in the treatment of dry eye disease. Besides the basic therapy including tear replacement, use of serum eye drops and mucolytic eye drops, the topical application of corticosteroids and cyclosporin A is more commonly used in moderate to severe forms of dry eye disease. The consistent treatment of Meibomian gland dysfunction as a frequent reason for evaporative dry eye is also of particular importance. Understanding the chronicity of the disease and long-term compliance are the essential for successful therapy of this widespread disease. PMID:25275793

  9. Increasing accessibility to the blind of virtual environments, using a virtual mobility aid based on the "EyeCane": feasibility study.

    PubMed

    Maidenbaum, Shachar; Levy-Tzedek, Shelly; Chebat, Daniel-Robert; Amedi, Amir

    2013-01-01

    Virtual worlds and environments are becoming an increasingly central part of our lives, yet they are still far from accessible to the blind. This is especially unfortunate as such environments hold great potential for them for uses such as social interaction, online education and especially for use with familiarizing the visually impaired user with a real environment virtually from the comfort and safety of his own home before visiting it in the real world. We have implemented a simple algorithm to improve this situation using single-point depth information, enabling the blind to use a virtual cane, modeled on the "EyeCane" electronic travel aid, within any virtual environment with minimal pre-processing. Use of the Virtual-EyeCane, enables this experience to potentially be later used in real world environments with identical stimuli to those from the virtual environment. We show the fast-learned practical use of this algorithm for navigation in simple environments. PMID:23977316

  10. Eye movement abnormalities.

    PubMed

    Moncayo, Jorge; Bogousslavsky, Julien

    2012-01-01

    Generation and control of eye movements requires the participation of the cortex, basal ganglia, cerebellum and brainstem. The signals of this complex neural network finally converge on the ocular motoneurons of the brainstem. Infarct or hemorrhage at any level of the oculomotor system (though more frequent in the brain-stem) may give rise to a broad spectrum of eye movement abnormalities (EMAs). Consequently, neurologists and particularly stroke neurologists are routinely confronted with EMAs, some of which may be overlooked in the acute stroke setting and others that, when recognized, may have a high localizing value. The most complex EMAs are due to midbrain stroke. Horizontal gaze disorders, some of them manifesting unusual patterns, may occur in pontine stroke. Distinct varieties of nystagmus occur in cerebellar and medullary stroke. This review summarizes the most representative EMAs from the supratentorial level to the brainstem. PMID:22377853

  11. Nutrition and the eye.

    PubMed

    Congdon, N G; West, K P

    1999-12-01

    The topic "nutrition and the eye" cannot adequately be covered in a single review article; indeed, dozens of books and hundreds of articles have been written on the subject. This review concentrates on three areas in which specific nutrients are known or theorized to have a major impact on vision and the visual system: vitamin A deficiency; antioxidants and their proposed role in the prevention of age-related cataract and macular degeneration; and nutritional optic neuropathies, including those of the recent Cuban epidemic. In addition, this article touches on nutritional treatments that have been suggested for several less common eye diseases and, finally, considers several less prevalent conditions in which deficiency of or excess exposure to a particular nutrient has been associated with ocular pathology. PMID:10662253

  12. [The eye and cancer].

    PubMed

    Schalenbourg, Ann; Mantel, Irmela

    2015-12-16

    Cancer involves so rarely the eye that it may be recognized late. The most frequent primary intra-ocular tumours are retinoblastoma in small children and uveal melanoma in adults. Vision loss in systemic cancer has a varied differential diagnosis. Uveal metastases are most often associated with breast cancer, but can herald lung carcinoma. Masquerade syndrome looks like inflammation but represents the ocular involvement of primary CNS non-Hodgkin lymphoma. Systemic cancer drugs, as well as radiotherapy, can cause ocular toxicity, mostly at the retina. In the rare paraneoplastic syndromes, patient's cancer antibodies cross-react with retinal antigens, leading to severe vision loss. When cancer involves the eye, a fast referral into specialized care can significantly improve visual and vital prognosis. PMID:26852556

  13. New two dimensional liquid-phase colorimetric assay based on old iodine-starch complexation for the naked-eye quantitative detection of analytes.

    PubMed

    Nie, Jinfang; Brown, Tom; Zhang, Yun

    2016-06-14

    A new type of quantitative point-of-care liquid-phase colorimetric assay (LPCA) termed as two dimensional (2D) LPCA is designed using old iodine-starch complexation reaction firstly discovered in 1814. The naked-eye 2D LPCA's utility is well demonstrated with the simple, low-cost, portable detection and quantification of model analytes in buffer and/or human serum samples without the use of external electronic readers. PMID:27074248

  14. Pioneers of eye movement research

    PubMed Central

    Wade, Nicholas J

    2010-01-01

    Recent advances in the technology affording eye movement recordings carry the risk of neglecting past achievements. Without the assistance of this modern armoury, great strides were made in describing the ways the eyes move. For Aristotle the fundamental features of eye movements were binocular, and he described the combined functions of the eyes. This was later given support using simple procedures like placing a finger over the eyelid of the closed eye and culminated in Hering's law of equal innervation. However, the overriding concern in the 19th century was with eye position rather than eye movements. Appreciating discontinuities of eye movements arose from studies of vertigo. The characteristics of nystagmus were recorded before those of saccades and fixations. Eye movements during reading were described by Hering and by Lamare in 1879; both used similar techniques of listening to sounds made during contractions of the extraocular muscles. Photographic records of eye movements during reading were made by Dodge early in the 20th century, and this stimulated research using a wider array of patterns. In the mid-20th century attention shifted to the stability of the eyes during fixation, with the emphasis on involuntary movements. The contributions of pioneers from Aristotle to Yarbus are outlined. PMID:23396982

  15. Eye preferences in captive chimpanzees.

    PubMed

    Braccini, Stephanie N; Lambeth, Susan P; Schapiro, Steven J; Fitch, W Tecumseh

    2012-09-01

    Over the last century, the issue of brain lateralization in primates has been extensively investigated and debated, yet no previous study has reported eye preference in great apes. This study examined eye preference in 45 captive chimpanzees (Pan troglodytes) in response to various stimuli. Eye preference was assessed when animals looked through a hole that only accommodated one eye at an empty box, a mirror, a picture of a dog, a rubber snake, food biscuits, bananas, a rubber duck, and a video camera. Main effects of stimulus type were found for direction of eye preference, number of looks, and looking duration, but not for strength of eye preference. A left-eye bias was found for viewing the rubber snake and a right-eye bias was found for viewing the bananas, supporting theories that emotional valence may affect lateralized behaviors. In addition, a significant shift in eye preference took place from the initial look to subsequent looks when viewing the snake. These results are not consistent with previous reports of human eye preference and may reflect lateralization differences for emotional processing. No relationship between eye preference and previously recorded hand preference was found. PMID:22733385

  16. Ultrasonic biomicroscopy in ophthalmology and eye banking

    NASA Astrophysics Data System (ADS)

    Rosenwasser, George O. D.

    1999-06-01

    Echography has become a valuable diagnostic tool in ophthalmology. Ultrasonic biomicroscopy (UBM) in particular may be applied to the evaluation of small lesions of the anterior segment of the eye. Disease processes such as conjunctival and iris melanoma, other forms of neoplasia, intraocular cysts, narrow angle glaucoma, and intraocular foreign bodies can be diagnostically evaluated and followed longitudinally by UBM. Combining UBM with spectroscopy may become useful in determining cell type origins of a variety of tumors. Eye banking also has an increased need for UBM in corneal tissue banking. The recent development of the Laser In Situ Keratomileusis procedure has allowed corneal surgeries to create a partial thickness flap of tissue in the cornea, remove tissue from the base of the cornea with excimer laser ablation, and replace the hinged flap. This causes a substantial change in refractive error while thinning the cornea and leaving an interface within the corneal stroma. The ability to detect this type of surgery is essential in eye banking. Ultrasonic pachymetry to determine central thickness and biomicroscopy to detect the presence of an interface are essential in avoiding the use of these corneas for transplantation purposes. Determining the topography of the preserved corneas is another potential application for ultrasonography. Using this information to reduce optical aberration after transplant is crucial in improving visual performance post transplantation. A review of the anatomy of the eye, pathology of ocular diseases relevant to UBM, and principles of eye banking will be presented.

  17. Michelangelo's eye disease.

    PubMed

    Gallenga, P E; Neri, Giampiero; D'Anastasio, Ruggero; Pettorrossi, Vito Enrico; Alfieri, Emilio; Capasso, Luigi

    2012-06-01

    Charged by the Pope Julius II for painting the Cappella Sistina in Rome (between 1508 and 1512), Michelangelo worked in an elevated scaffolding, in an anomalous position with dyes (including poisoning lead salts) and solvents (such as toxic turpentine) dripping on his face and continuously inhaling, in a dim environment illuminated only with oil lamps and candles, as he described himself and sketched in a sonet addressed to Giovanni da Pistoia. In 1510 he began suffering from eye disease: the main symptom was the necessity to elevate the document he was reading up to the level of his eyes. This defect disappeared few months after he finished painting his masterpiece. We hypothesize that the Michelangelo's eyes disease was a form of acquired and transitory nystagmus induced by the many hours he spent in up gaze, with a skew deviation, a form of ocular tilt reaction resulting from the impairment of spatial sensitivity (inversion illusion) due to the persistence of the artist's head in a horizontal position, looking upward. PMID:22425178

  18. Schizophrenia and the eye

    PubMed Central

    Silverstein, Steven M.; Rosen, Richard

    2015-01-01

    Although visual processing impairments are common in schizophrenia, it is not clear to what extent these originate in the eye vs. the brain. This review highlights potential contributions, from the retina and other structures of the eye, tovisual processing impairments in schizophrenia and high-risk states. A second goal is to evaluate the status of retinal abnormalities as biomarkers for schizophrenia. The review was motivated by known retinal changes in other disorders (e.g., Parkinson's disease, multiple sclerosis), and their relationships to perceptual and cognitive impairments, and disease progression therein. The evidence reviewed suggests two major conclusions. One is that there are multiple structural and functional disturbances of the eye in schizophrenia, all of which could be factors in the visual disturbances of patients. These include retinal venule widening, retinal nerve fiber layer thinning, dopaminergic abnormalities, abnormal ouput of retinal cells as measured by electroretinography (ERG), maculopathies and retinopathies, cataracts, poor acuity, and strabismus. Some of these are likely to be illness-related, whereas others may be due to medication or comorbid conditions. The second conclusion is that certain retinal findings can serve as biomarkers of neural pathology, and disease progression, in schizophrenia. The strongest evidence for this to date involves findings of widened retinal venules, thinning of the retinal nerve fiber layer, and abnormal ERG amplitudes. These data suggest that a greater understanding of the contribution of retinal and other ocular pathology to the visual and cognitive disturbances of schizophrenia is warranted, and that retinal changes have untapped clinical utility. PMID:26345525

  19. Christoph Scheiner's eye studies.

    PubMed

    Daxecker, F

    1992-01-01

    Christoph Scheiner was born in 1573 or 1575. In 1595 he entered into the Order of the Jesuits; he died in 1650. In 1619 his book Oculus, dealing with the optics of the eye, appeared in Innsbruck. The invention of the telescope was of utmost importance for progress in astronomical and physical research. Scheiner himself built telescopes and discovered the sunspots. As a result, an unpleasant priority dispute with Galilei ensued. From 1624 onwards, Scheiner was in Rome, where his main work Rosa Ursina was published in 1630. A part of this book deals with the physiological optics of the eye as well. Some of his discoveries and experiments are taken from these two books: determination of the radius of curvature of the cornea, discovery of the nasal exit of the optic nerve, increase in the radius of curvature of the lens in case of accommodation, Scheiner's procedure (double images with ametropia), refractive indices of various parts of the eye, Scheiner's experiment. Without any doubt, Christoph Scheiner belongs to the foremost scientists of the first half of the 17th century. PMID:1473465

  20. Natural coordinates for specification of eye movements.

    PubMed

    Clement, R A

    1991-01-01

    Tweed and Vilis (Journal of Neurophysiology, 58, 832-849, 1987) have argued that quaternion algebra provides the most appropriate description of the rotations of the eye, and have derived a three-dimensional model of gaze control based on quaternion operations. Euler angles give a simpler description of the rotations of the eye, and can also be used to formulate an alternative version of the three-dimensional gaze control model. Comparison of the two versions of the model highlights the distinction between the functional predictions of the model, and the predictions which depend only on the choice of mathematical descriptions. PMID:1771787

  1. Eye-gaze driven surgical workflow segmentation.

    PubMed

    James, A; Vieira, D; Lo, B; Darzi, A; Yang, G Z

    2007-01-01

    In today's climate of clinical governance there is growing pressure on surgeons to demonstrate their competence, improve standards and reduce surgical errors. This paper presents a study on developing a novel eye-gaze driven technique for surgical assessment and workflow recovery. The proposed technique investigates the use of a Parallel Layer Perceptor (PLP) to automate the recognition of a key surgical step in a porcine laparoscopic cholecystectomy model. The classifier is eye-gaze contingent but combined with image based visual feature detection for improved system performance. Experimental results show that by fusing image instrument likelihood measures, an overall classification accuracy of 75% is achieved. PMID:18044559

  2. Eye model for the ground squirrel

    NASA Astrophysics Data System (ADS)

    Sussman, Dafna; Chou, B. Ralph; Lakshminarayanan, Vasudevan

    2011-11-01

    This paper presents an anatomically-correct eye model for the ground squirrel, a diurnal, highly-developed mammal with high visual acuity. This model can assist in understanding the relationship between ocular structural development and its corresponding function. The eye model is constructed based on anatomical measurements of thicknesses and indices of refraction of the various ocular media. The model then derives the gradient index distribution of the crystalline lens using a ray tracing method with a Monte Carlo optimization. Results indicate a diffraction-limited ocular behaviour, implying the visual acuity of the ground squirrel is more likely to be limited by photoreceptor density and diffraction effects, than by ocular geometry.

  3. Visibility limit of naked-eye sunspots

    NASA Astrophysics Data System (ADS)

    Keller, H. U.; Friedli, T. K.

    1992-06-01

    Based on observations of 20 observers, a visibility limit for naked-eye sunspot observations has been calculated. A sunspot with a penumbral diameter of at least 41 arcsec and an umbral diameter of at least 15 arcsec can be detected by an average eye. An eyesight test was designed to solve the question whether the penumbral or the umbral diameter is conclusive for the visibility of a sunspot. The measured limit of 19.3 arcsec indicates that a combination of both is the determining factor.

  4. Cortexin diffusion in human eye sclera

    SciTech Connect

    Genina, Elina A; Bashkatov, A N; Tuchin, Valerii V; Ghosn, M G; Larin, Kirill V; Kamenskikh, T G

    2011-05-31

    Investigation of the diffusion of cytamines, a typical representative of which is cortexin, is important for evaluating the drug dose, necessary to provide sufficient concentration of the preparation in the inner tissues of the eye. In the present paper, the cortexin diffusion rate in the eye sclera is measured using the methods of optical coherence tomography (OCT) and reflectance spectroscopy. The technique for determining the diffusion coefficient is based on the registration of temporal dependence of the eye sclera scattering parameters caused by partial replacement of interstitial fluid with the aqueous cortexin solution, which reduces the level of the OCT signal and decreases the reflectance of the sclera. The values of the cortexin diffusion coefficient obtained using two independent optical methods are in good agreement. (optical technologies in biophysics and medicine)

  5. Effects of tear gases on the eye.

    PubMed

    Kim, Yonwook J; Payal, Abhishek R; Daly, Mary K

    2016-01-01

    Chemical agents that target the eyes have been a popular choice for law enforcement during riots and for military training for nearly a century. The most commonly used agents are chloroacetophenone (formerly sold as Mace), o-chlorobenzylidene malononitrile, and oleoresin capsicum (OC or pepper spray, current ingredient for Mace). Initially, most severe ocular injuries were caused by the explosive force rather than the chemical itself. The development of sprays reduced the mechanical severity of ocular injuries, but resulted in a variety of chemical injuries. The effects on eyes include conjunctival injection, complete corneal epithelial defects, pseudopterygium, corneal neovascularization, persistent conjunctivalization, corneal opacities, and reduced visual acuity. Current management, based on limited human studies, emphasizes decontamination and symptomatic treatment. We review the literature related to clinical and histopathologic effects of tear gas agents on the eye and their management. PMID:26808721

  6. Optical eye simulator for laser dazzle events.

    PubMed

    Coelho, João M P; Freitas, José; Williamson, Craig A

    2016-03-20

    An optical simulator of the human eye and its application to laser dazzle events are presented. The simulator combines optical design software (ZEMAX) with a scientific programming language (MATLAB) and allows the user to implement and analyze a dazzle scenario using practical, real-world parameters. Contrary to conventional analytical glare analysis, this work uses ray tracing and the scattering model and parameters for each optical element of the eye. The theoretical background of each such element is presented in relation to the model. The overall simulator's calibration, validation, and performance analysis are achieved by comparison with a simpler model based uponCIE disability glare data. Results demonstrate that this kind of advanced optical eye simulation can be used to represent laser dazzle and has the potential to extend the range of applicability of analytical models. PMID:27140558

  7. Eye Movement Correlates of Acquired Central Dyslexia

    ERIC Educational Resources Information Center

    Schattka, Kerstin I.; Radach, Ralph; Huber, Walter

    2010-01-01

    Based on recent progress in theory and measurement techniques, the analysis of eye movements has become one of the major methodological tools in experimental reading research. Our work uses this approach to advance the understanding of impaired information processing in acquired central dyslexia of stroke patients with aphasia. Up to now there has…

  8. "Dry Eye" Is the Wrong Diagnosis for Millions.

    PubMed

    Korb, Donald R; Blackie, Caroline A

    2015-09-01

    The clinical perspective that dry eye is, at best, an incomplete diagnosis and the benefit of an etiology-based approach to dry eye are presented. To provide context for this perspective, the historical and current definition of dry eye is reviewed. The paradigm shift introduced by the Meibomian Gland Dysfunction (MGD) Workshop, that MGD is likely the leading cause of dry eye, is discussed in combination with the advancements in the diagnosis and treatment of MGD. To facilitate discussion on the benefit of an etiology-based approach, a retrospective observational analysis was performed on deidentified data from eligible, fully consented, refractory dry eye patients, where conventional sequelae-based dry eye treatment had failed. In this refractory population, the diagnosis of MGD, which directed treatment to evacuating gland obstructions and rehabilitating gland function, was successful. The clinical perspective that "dry eye" is the wrong diagnosis for millions is provocative. However, the MGD-first approach has the potential to revolutionize the timing of diagnosis and the choice of frontline therapy in most patients with dry eye. Additionally, the ability to screen for MGD in its earliest stages, during routine care, expands the scope of clinical practice to include early intervention. For most patients, we are no longer constrained to delay diagnosis until the tear film has decompensated and the cascade of inflammation has ensued. We do not have to wait for our patients to tell us there is a problem. PMID:26204473

  9. Novel hydroxypropyl-guar gellable lubricant eye drops for treatment of dry eye.

    PubMed

    Springs, Clark L

    2010-10-01

    OBJECTIVE|: The objective of this review is to evaluate the safety and efficacy of polyethylene glycol 400/propylene glycol/hydroxypropyl-guar (Systane® Ultra [PEG/PG with HP-guar], Alcon Laboratories, Inc., Fort Worth, TX, USA) lubricant eye drops in reducing the signs and symptoms of dry-eye disease. METHODS|: A systematic literature search utilizing MEDLINE was conducted to identify peer-reviewed articles related to dry-eye disease and PEG/PG with HP-guar lubricant eye drops. The search covered the period prior to October 2009. Additionally, a manual search based on citations in the published literature was conducted. RESULTS|: The PEG/PG with HP-guar artificial tears shows in-vitro viscoelastic properties with pH optimization. The pH of the solution adjusts to the pH of the ocular surface upon instillation, which results in tear film elasticity and viscosity similar to that of subjects without dry-eye disease. The reviewed literature demonstrated that this delivery system showed a reduction in corneal and conjunctival staining in dryeye disease, an improvement in tear film stability, a low coefficient of friction in an in-vitro model, and improved maintenance of best-corrected visual acuity over time. CONCLUSION|: A few small-sized studies with short-term follow-up demonstrated that PEG/PG with HP-guar is a safe and effective lubricant eye drops for the treatment of dry-eye disease. Larger studies with longer duration are warranted to assess the long-term safety and efficacy of this formulation in patients with dry.eye disease. PMID:20803266

  10. Electroanalytical and naked eye determination of Cu(2+) ion in various environmental samples using 5-amino-1,3,4-thiadiazole-2-thiol based Schiff bases.

    PubMed

    Bandi, Koteswara Rao; Singh, Ashok Kumar; Upadhyay, Anjali

    2014-01-01

    Novel polydentate Schiff bases 4-(5-mercapto-1,3,4-thiadiazol-2-ylimino)pentan-2-one (S1) and (2-(indol-3-yl)vinyl)-1,3,4-thiadiazole-2-thiol (S2) were synthesized and explored as Cu(2+) selective polymeric membrane electrodes (PME) using different plasticizers and anionic excluders. The potentiometric data revealed that the PME having the membrane composition (S2: NaTPB: TBP: PVC as 4: 2: 58: 36 (w/w; mg)) is shown to have good results. Thus the coated graphite electrode (CGE) with the same composition as the best PME was also fabricated and investigated as Cu(2+) selective electrode. It was found that CGE showed better response characteristics than PME with respect to low detection limit (1.2×10(-8)molL(-1)), near Nernstian slope (29.8±0.4mV decade(-1) of activity), wide working concentration range (6.4×10(-8)-1.0×10(-1)molL(-1)), long shelf life (90days) and fast response time (9s). The CGE was used successfully as an indicator electrode for the potentiometric determination of Cu(2+) ion against EDTA and also used to quantify Cu(2+) ion in soil, water, medicinal plants, vegetables and edible oil samples. The Schiff base S2 is used as chemosensor for the selective determination of Cu(2+) ion. PMID:24268244

  11. Genetic analyses of the human eye colours using a novel objective method for eye colour classification.

    PubMed

    Andersen, Jeppe D; Johansen, Peter; Harder, Stine; Christoffersen, Susanne R; Delgado, Mikaela C; Henriksen, Sarah T; Nielsen, Mette M; Sørensen, Erik; Ullum, Henrik; Hansen, Thomas; Dahl, Anders L; Paulsen, Rasmus R; Børsting, Claus; Morling, Niels

    2013-09-01

    In this study, we present a new objective method for measuring the eye colour on a continuous scale that allows researchers to associate genetic markers with different shades of eye colour. With the use of the custom designed software Digital Iris Analysis Tool (DIAT), the iris was automatically identified and extracted from high resolution digital images. DIAT was made user friendly with a graphical user interface. The software counted the number of blue and brown pixels in the iris image and calculated a Pixel Index of the Eye (PIE-score) that described the eye colour quantitatively. The PIE-score ranged from -1 to 1 (brown to blue). The software eliminated the need for user based interpretation and qualitative eye colour categories. In 94% (570) of 605 analyzed eye images, the iris region was successfully extracted and a PIE-score was calculated. A very high correlation between the PIE-score and the human perception of eye colour was observed. The correlations between the PIE-scores and the six IrisPlex SNPs (HERC2 rs12913832, OCA2 rs1800407, SLC24A4 rs12896399, TYR rs1393350, SLC45A2 rs16891982 and IRF4 rs12203592) were analyzed in 570 individuals. Significant differences (p<10(-6)) in the PIE-scores of the individuals typed as HERC2 rs12913832 G (PIE=0.99) and rs12913832 GA (PIE=-0.71) or A (PIE=-0.87) were observed. We adjusted for the effect of HERC2 rs12913832 and showed that the quantitative PIE-scores were significantly associated with SNPs with minor effects (OCA2 rs1800407, SLC24A4 rs12896399 and TYR rs1393350) on the eye colour. We evaluated the two published prediction models for eye colour (IrisPlex [1] and Snipper[2]) and compared the predictions with the PIE-scores. We found good concordance with the prediction from individuals typed as HERC2 rs12913832 G. However, both methods had difficulties in categorizing individuals typed as HERC2 rs12913832 GA because of the large variation in eye colour in HERC2 rs12913832 GA individuals. With the use of

  12. Eye safety: irritants, exposure effects, and protective devices. January 1975-March 1989 (Citations from the INSPEC: Information Services for the Physics and Engineering Communities data base). Report for January 1975-March 1989

    SciTech Connect

    Not Available

    1989-04-01

    This bibliography contains citations concerning the development, performance and applications of eye-protection devices. Eye protection from laser radiation is examined. Eye safe hand-held laser range finders, laser beam safety in tactical training, human eye exposure limitations to laser radiation, and the development and testing of protective goggles and glasses against laser beams are discussed. Fluorescent lighting effects on the human eye, eye strain from visual display units, and the use of closed circuit TV for monitoring hazardous engineering processes are considered. (This updated bibliography contains 260 citations, 40 of which are new entries to the previous edition.)

  13. Eyes wide shut: amygdala mediates eyes-closed effect on emotional experience with music.

    PubMed

    Lerner, Yulia; Papo, David; Zhdanov, Andrey; Belozersky, Libi; Hendler, Talma

    2009-01-01

    The perceived emotional value of stimuli and, as a consequence the subjective emotional experience with them, can be affected by context-dependent styles of processing. Therefore, the investigation of the neural correlates of emotional experience requires accounting for such a variable, a matter of an experimental challenge. Closing the eyes affects the style of attending to auditory stimuli by modifying the perceptual relationship with the environment without changing the stimulus itself. In the current study, we used fMRI to characterize the neural mediators of such modification on the experience of emotionality in music. We assumed that closed eyes position will reveal interplay between different levels of neural processing of emotions. More specifically, we focused on the amygdala as a central node of the limbic system and on its co-activation with the Locus Ceruleus (LC) and Ventral Prefrontal Cortex (VPFC); regions involved in processing of, respectively, 'low', visceral-, and 'high', cognitive-related, values of emotional stimuli. Fifteen healthy subjects listened to negative and neutral music excerpts with eyes closed or open. As expected, behavioral results showed that closing the eyes while listening to emotional music resulted in enhanced rating of emotionality, specifically of negative music. In correspondence, fMRI results showed greater activation in the amygdala when subjects listened to the emotional music with eyes closed relative to eyes open. More so, by using voxel-based correlation and a dynamic causal model analyses we demonstrated that increased amygdala activation to negative music with eyes closed led to increased activations in the LC and VPFC. This finding supports a system-based model of perceived emotionality in which the amygdala has a central role in mediating the effect of context-based processing style by recruiting neural operations involved in both visceral (i.e. 'low') and cognitive (i.e. 'high') related processes of emotions

  14. [Eye and the environment].

    PubMed

    Voide, Nathalie; Kaeser, Pierre-François; Behar-Cohen, Francine

    2015-12-16

    The eyes are exposed to multiple environmental factors, which affect visual development, comfort, and visual health. While overexposure to sunlight can cause ocular surface and retinal pathologies, insufficient exposure to daylight could significantly contribute to myopia progression. New artificial lights, namely LED, have a higher risk of retinal phototoxicity, and could alter ocular circadian rhythm. The significant increase of prevalence of ocular allergies could be caused by the proliferation of environmental polluting substances, like tobacco smoke, fuel combustion by-products, or phtalates, which are found in many types of plastics. Finally, some dietary supplements could play a protective role in certain types of ocular pathologies, namely retinal pathologies. PMID:26852551

  15. Pathology of a lepromatous eye.

    PubMed

    Ebenezer, G J; Daniel, E

    2000-03-01

    Histopathological examination of an enucleated eye from a lepromatous leprosy patient showed the cornea, ciliary body, and part of the choroid to be infiltrated by macrophages filled with Mycobacterium leprae. The walls of blood vessels in the sclera, ciliary body and the anterior choroid demonstrated the presence of M. leprae, giving credence to the blood-borne entry of M. leprae into the eye. Unlike the eyes of experimental animals infected with M. leprae, histopathological study of this eye from a lepromatous leprosy patient demonstrated that M. leprae, although demonstrable in the anterior choroid, could not be found in the posterior parts of the eye, substantiating the claim that leprosy does not affect the posterior parts of the eye directly. PMID:10834066

  16. Perceived visual motion as effective stimulus to pursuit eye movement system

    NASA Technical Reports Server (NTRS)

    Yasui, S.; Young, L. R.

    1975-01-01

    Human eye tracking of a foveal afterimage during angular head oscillation in the dark produced smooth eye movements exceeding those for normal vestibular nystagmus, and a reduction in the frequency of the fast phase component of nystagmus eye movements. These results may support a closed loop extension of the corollary discharge theory, with oculomotor commands based on perceived object velocity.

  17. Aging and dry eye disease

    PubMed Central

    Ding, Juan; Sullivan, David A.

    2012-01-01

    Dry eye disease is a prevalent eye disorder that in particular affects the elderly population. One of the major causes of dry eye, meibomian gland dysfunction (MGD), shows increased prevalence with aging. MGD is caused by hyperkeratinization of the ductal epithelium of meibomian gland and reduced quantity and/or quality of meibum, the holocrine product that stabilizes and prevents the evaporation of the tear film. Of note, retinoids which are used in current anti-aging cosmetics may promote the development of MGD and dry eye disease. In this review, we will discuss the possible mechanisms of age-related MGD. PMID:22569356

  18. A novel approach to formulation factor of aceclofenac eye drops efficiency evaluation based on physicochemical characteristics of in vitro and in vivo permeation

    PubMed Central

    Dave, Vivek; Paliwal, Sarvesh

    2013-01-01

    The purpose of the present study was to evaluate aceclofenac eye drop through excised goat cornea. Raising pH of the formulation from 6.0 to 8.0, effect of different preservatives or effect of viscosity enhancer decreases apparent permeability coefficient. Topical ophthalmic NSAID are used to treat ocular surface and anterior segment inflammation as well as post operative management of pain and inflammation. Aceclofenac’s unique chemical structure makes it both a potent anti inflammatory drug and lipophilic molecule that penetrates ocular tissue, ensuring relief of pain in cataract and refractive surgery and corneal abrasion. The octanol/water partition coefficient of aceclofenac drug is 1.86 ± 0.75. Permeation characteristics of the drug were evaluated by putting 1 ml formulation on freshly excised goat cornea fixed between donor and receptor compartments of an all-glass modified Franz diffusion cell and measuring the drug permeated in the receptor by spectrophotometry at 275 nm, after 120 min. The results suggest that aceclofenac ophthalmic solution (pH 7) containing BAC provides increased in vitro ocular availability through goat corneas. The combination of methyl paraben and propyl paraben MP–PP preservative in aceclofenac ophthalmic eye drop 0.1% formulated in phosphate buffer increases transcorneal permeation. The developed formulations were evaluated for their pharmacodynamics in albino rabbits, by measuring in-vivo study and were compared to a marketed voltrane ophthalmic solution. PMID:25061410

  19. A novel approach to formulation factor of aceclofenac eye drops efficiency evaluation based on physicochemical characteristics of in vitro and in vivo permeation.

    PubMed

    Dave, Vivek; Paliwal, Sarvesh

    2014-07-01

    The purpose of the present study was to evaluate aceclofenac eye drop through excised goat cornea. Raising pH of the formulation from 6.0 to 8.0, effect of different preservatives or effect of viscosity enhancer decreases apparent permeability coefficient. Topical ophthalmic NSAID are used to treat ocular surface and anterior segment inflammation as well as post operative management of pain and inflammation. Aceclofenac's unique chemical structure makes it both a potent anti inflammatory drug and lipophilic molecule that penetrates ocular tissue, ensuring relief of pain in cataract and refractive surgery and corneal abrasion. The octanol/water partition coefficient of aceclofenac drug is 1.86 ± 0.75. Permeation characteristics of the drug were evaluated by putting 1 ml formulation on freshly excised goat cornea fixed between donor and receptor compartments of an all-glass modified Franz diffusion cell and measuring the drug permeated in the receptor by spectrophotometry at 275 nm, after 120 min. The results suggest that aceclofenac ophthalmic solution (pH 7) containing BAC provides increased in vitro ocular availability through goat corneas. The combination of methyl paraben and propyl paraben MP-PP preservative in aceclofenac ophthalmic eye drop 0.1% formulated in phosphate buffer increases transcorneal permeation. The developed formulations were evaluated for their pharmacodynamics in albino rabbits, by measuring in-vivo study and were compared to a marketed voltrane ophthalmic solution. PMID:25061410

  20. Eye Surgery Light

    NASA Technical Reports Server (NTRS)

    1978-01-01

    During eye surgery, the surgeon uses an illuminating instrument called an opthalmoscope for close examination of the retina or the interior of the eye. Ordinarily, electric power for the head-mounted light is supplied through a cord from an overhead swivel arm or a floor pedestal. Within limits of cord length and swivel arm movement, the surgeon has considerable freedom of motion. But when more than one opthalmoscope is involved, tangling and interference of the power cords becomes a problem. St. Luke's Hospital, Cleveland, Ohio asked Lewis Research Center for assistance in finding a solution. Lewis responded with a battery-powered system that totally frees the surgeon of attached cords and swivels. Borrowing from space technology, Lewis used small, lightweight nickel-cadmium batteries that can deliver high intensity light for an hour and can be recharged overnight. The Opthalmoscope Powerpack consists of eight batteries in three containers affixed to a webbed belt, and a novel on-off switch equipped with a springloaded plexiglass "flapper." The belt pack is worn underneath the surgical gown and the flapper permits the doctor to activate the switch by elbow pressure. Lewis built five units and they have been in service at St. Luke's Hospital for a year. Used for routine examinations as well as for surgery, they have demonstrated excellent reliability.

  1. Eye Surgery Light

    NASA Technical Reports Server (NTRS)

    1978-01-01

    During eye surgery, the surgeon uses an illuminating instrument called an opthalmoscope for close examination of the retina or the interior of the eye. Ordinarily, electric power for the head-mounted light is supplied through a cord from an overhead swivel arm or a floor pedestal. Within limits of cord length and swivel arm movement, the surgeon has considerable freedom of motion. But when more than one opthalmoscope is involved, tangling and interference of the power cords becomes a problem. St. Luke's Hospital, Cleveland, Ohio asked Lewis Research Center for assistance in finding a solution. Lewis responded with a battery-powered system that totally frees the surgeon of attached cords and swivels. Borrowing from space technology, Lewis used small, lightweight nickel-cadmium batteries that can deliver high intensity light for an hour and can be recharged overnight. The Opthalmoscope Powerpack consists of eight batteries in three containers affixed to a webbed belt, and a novel on-off switch equipped with a spring-loaded plexiglass 'flapper.' The belt pack is worn underneath the surgical gown and the flapper permits the doctor to activate the switch by elbow pressure. Lewis built five units and they have been in service at St. Luke's Hospital for a year. Used for routine examinations as well as for surgery, they have demonstrated excellent reliability.

  2. Alternative methods for the replacement of eye irritation testing.

    PubMed

    Lotz, Christian; Schmid, Freia F; Rossi, Angela; Kurdyn, Szymon; Kampik, Daniel; De Wever, Bart; Walles, Heike; Groeber, Florian K

    2016-01-01

    In the last decades significant regulatory attempts were made to replace, refine and reduce animal testing to assess the risk of consumer products for the human eye. As the original in vivo Draize eye test has been criticized for limited predictivity, costs and ethical issues, several animal-free test methods have been developed to categorize substances according to the global harmonized system (GHS) for eye irritation.This review summarizes the progress of alternative test methods for the assessment of eye irritation. Based on the corneal anatomy and the current knowledge of the mechanisms causing eye irritation, different ex vivo and in vitro methods will be presented and discussed in regard of possible limitations and their status of regulatory acceptance. In addition to established in vitro models, this review will also highlight emerging, full thickness cornea models that might be applicable to predict all GHS categories. PMID:26626125

  3. Multimodal emotion recognition using EEG and eye tracking data.

    PubMed

    Zheng, Wei-Long; Dong, Bo-Nan; Lu, Bao-Liang

    2014-01-01

    This paper presents a new emotion recognition method which combines electroencephalograph (EEG) signals and pupillary response collected from eye tracker. We select 15 emotional film clips of 3 categories (positive, neutral and negative). The EEG signals and eye tracking data of five participants are recorded, simultaneously, while watching these videos. We extract emotion-relevant features from EEG signals and eye tracing data of 12 experiments and build a fusion model to improve the performance of emotion recognition. The best average accuracies based on EEG signals and eye tracking data are 71.77% and 58.90%, respectively. We also achieve average accuracies of 73.59% and 72.98% for feature level fusion strategy and decision level fusion strategy, respectively. These results show that both feature level fusion and decision level fusion combining EEG signals and eye tracking data can improve the performance of emotion recognition model. PMID:25571125

  4. Simultaneous Eye Tracking and Blink Detection with Interactive Particle Filters

    NASA Astrophysics Data System (ADS)

    Wu, Junwen; Trivedi, Mohan M.

    2007-12-01

    We present a system that simultaneously tracks eyes and detects eye blinks. Two interactive particle filters are used for this purpose, one for the closed eyes and the other one for the open eyes. Each particle filter is used to track the eye locations as well as the scales of the eye subjects. The set of particles that gives higher confidence is defined as the primary set and the other one is defined as the secondary set. The eye location is estimated by the primary particle filter, and whether the eye status is open or closed is also decided by the label of the primary particle filter. When a new frame comes, the secondary particle filter is reinitialized according to the estimates from the primary particle filter. We use autoregression models for describing the state transition and a classification-based model for measuring the observation. Tensor subspace analysis is used for feature extraction which is followed by a logistic regression model to give the posterior estimation. The performance is carefully evaluated from two aspects: the blink detection rate and the tracking accuracy. The blink detection rate is evaluated using videos from varying scenarios, and the tracking accuracy is given by comparing with the benchmark data obtained using the Vicon motion capturing system. The setup for obtaining benchmark data for tracking accuracy evaluation is presented and experimental results are shown. Extensive experimental evaluations validate the capability of the algorithm.

  5. Automatic red eye correction and its quality metric

    NASA Astrophysics Data System (ADS)

    Safonov, Ilia V.; Rychagov, Michael N.; Kang, KiMin; Kim, Sang Ho

    2008-01-01

    The red eye artifacts are troublesome defect of amateur photos. Correction of red eyes during printing without user intervention and making photos more pleasant for an observer are important tasks. The novel efficient technique of automatic correction of red eyes aimed for photo printers is proposed. This algorithm is independent from face orientation and capable to detect paired red eyes as well as single red eyes. The approach is based on application of 3D tables with typicalness levels for red eyes and human skin tones and directional edge detection filters for processing of redness image. Machine learning is applied for feature selection. For classification of red eye regions a cascade of classifiers including Gentle AdaBoost committee from Classification and Regression Trees (CART) is applied. Retouching stage includes desaturation, darkening and blending with initial image. Several versions of approach implementation using trade-off between detection and correction quality, processing time, memory volume are possible. The numeric quality criterion of automatic red eye correction is proposed. This quality metric is constructed by applying Analytic Hierarchy Process (AHP) for consumer opinions about correction outcomes. Proposed numeric metric helped to choose algorithm parameters via optimization procedure. Experimental results demonstrate high accuracy and efficiency of the proposed algorithm in comparison with existing solutions.

  6. Accurate eye center location through invariant isocentric patterns.

    PubMed

    Valenti, Roberto; Gevers, Theo

    2012-09-01

    Locating the center of the eyes allows for valuable information to be captured and used in a wide range of applications. Accurate eye center location can be determined using commercial eye-gaze trackers, but additional constraints and expensive hardware make these existing solutions unattractive and impossible to use on standard (i.e., visible wavelength), low-resolution images of eyes. Systems based solely on appearance are proposed in the literature, but their accuracy does not allow us to accurately locate and distinguish eye centers movements in these low-resolution settings. Our aim is to bridge this gap by locating the center of the eye within the area of the pupil on low-resolution images taken from a webcam or a similar device. The proposed method makes use of isophote properties to gain invariance to linear lighting changes (contrast and brightness), to achieve in-plane rotational invariance, and to keep low-computational costs. To further gain scale invariance, the approach is applied to a scale space pyramid. In this paper, we extensively test our approach for its robustness to changes in illumination, head pose, scale, occlusion, and eye rotation. We demonstrate that our system can achieve a significant improvement in accuracy over state-of-the-art techniques for eye center location in standard low-resolution imagery. PMID:22813958

  7. Double Eye Brow: A Rare Case Report

    PubMed Central

    Kar, Sudipta; Ghosh, Chiranjit; Bazmi, Badruddin Ahamed; Sarkar, Subrata

    2013-01-01

    Eye brows are essential for esthetic and functional purposes. Various kinds of eye brows are found in human species. Protective function is one of the important functions of eye brows. Double eye brow is a very rare condition found in human. This case report describes one of the rare cases of double eye brow. PMID:24574697

  8. Computer Analysis of Eye Blood-Vessel Images

    NASA Technical Reports Server (NTRS)

    Wall, R. J.; White, B. S.

    1984-01-01

    Technique rapidly diagnoses diabetes mellitus. Photographs of "whites" of patients' eyes scanned by computerized image analyzer programmed to quantify density of small blood vessels in conjuctiva. Comparison with data base of known normal and diabetic patients facilitates rapid diagnosis.

  9. Wavefront Derived Refraction and Full Eye Biometry in Pseudophakic Eyes

    PubMed Central

    Mao, Xinjie; Banta, James T.; Ke, Bilian; Jiang, Hong; He, Jichang; Liu, Che; Wang, Jianhua

    2016-01-01

    Purpose To assess wavefront derived refraction and full eye biometry including ciliary muscle dimension and full eye axial geometry in pseudophakic eyes using spectral domain OCT equipped with a Shack-Hartmann wavefront sensor. Methods Twenty-eight adult subjects (32 pseudophakic eyes) having recently undergone cataract surgery were enrolled in this study. A custom system combining two optical coherence tomography systems with a Shack-Hartmann wavefront sensor was constructed to image and monitor changes in whole eye biometry, the ciliary muscle and ocular aberration in the pseudophakic eye. A Badal optical channel and a visual target aligning with the wavefront sensor were incorporated into the system for measuring the wavefront-derived refraction. The imaging acquisition was performed twice. The coefficients of repeatability (CoR) and intraclass correlation coefficient (ICC) were calculated. Results Images were acquired and processed successfully in all patients. No significant difference was detected between repeated measurements of ciliary muscle dimension, full-eye biometry or defocus aberration. The CoR of full-eye biometry ranged from 0.36% to 3.04% and the ICC ranged from 0.981 to 0.999. The CoR for ciliary muscle dimensions ranged from 12.2% to 41.6% and the ICC ranged from 0.767 to 0.919. The defocus aberrations of the two measurements were 0.443 ± 0.534 D and 0.447 ± 0.586 D and the ICC was 0.951. Conclusions The combined system is capable of measuring full eye biometry and refraction with good repeatability. The system is suitable for future investigation of pseudoaccommodation in the pseudophakic eye. PMID:27010674

  10. Method for Improving EEG Based Emotion Recognition by Combining It with Synchronized Biometric and Eye Tracking Technologies in a Non-invasive and Low Cost Way

    PubMed Central

    López-Gil, Juan-Miguel; Virgili-Gomá, Jordi; Gil, Rosa; García, Roberto

    2016-01-01

    Technical advances, particularly the integration of wearable and embedded sensors, facilitate tracking of physiological responses in a less intrusive way. Currently, there are many devices that allow gathering biometric measurements from human beings, such as EEG Headsets or Health Bracelets. The massive data sets generated by tracking of EEG and physiology may be used, among other things, to infer knowledge about human moods and emotions. Apart from direct biometric signal measurement, eye tracking systems are nowadays capable of determining the point of gaze of the users when interacting in ICT environments, which provides an added value research on many different areas, such as psychology or marketing. We present a process in which devices for eye tracking, biometric, and EEG signal measurements are synchronously used for studying both basic and complex emotions. We selected the least intrusive devices for different signal data collection given the study requirements and cost constraints, so users would behave in the most natural way possible. On the one hand, we have been able to determine basic emotions participants were experiencing by means of valence and arousal. On the other hand, a complex emotion such as empathy has also been detected. To validate the usefulness of this approach, a study involving forty-four people has been carried out, where they were exposed to a series of affective stimuli while their EEG activity, biometric signals, and eye position were synchronously recorded to detect self-regulation. The hypothesis of the work was that people who self-regulated would show significantly different results when analyzing their EEG data. Participants were divided into two groups depending on whether Electro Dermal Activity (EDA) data indicated they self-regulated or not. The comparison of the results obtained using different machine learning algorithms for emotion recognition shows that using EEG activity alone as a predictor for self-regulation does

  11. Method for Improving EEG Based Emotion Recognition by Combining It with Synchronized Biometric and Eye Tracking Technologies in a Non-invasive and Low Cost Way.

    PubMed

    López-Gil, Juan-Miguel; Virgili-Gomá, Jordi; Gil, Rosa; García, Roberto

    2016-01-01

    Technical advances, particularly the integration of wearable and embedded sensors, facilitate tracking of physiological responses in a less intrusive way. Currently, there are many devices that allow gathering biometric measurements from human beings, such as EEG Headsets or Health Bracelets. The massive data sets generated by tracking of EEG and physiology may be used, among other things, to infer knowledge about human moods and emotions. Apart from direct biometric signal measurement, eye tracking systems are nowadays capable of determining the point of gaze of the users when interacting in ICT environments, which provides an added value research on many different areas, such as psychology or marketing. We present a process in which devices for eye tracking, biometric, and EEG signal measurements are synchronously used for studying both basic and complex emotions. We selected the least intrusive devices for different signal data collection given the study requirements and cost constraints, so users would behave in the most natural way possible. On the one hand, we have been able to determine basic emotions participants were experiencing by means of valence and arousal. On the other hand, a complex emotion such as empathy has also been detected. To validate the usefulness of this approach, a study involving forty-four people has been carried out, where they were exposed to a series of affective stimuli while their EEG activity, biometric signals, and eye position were synchronously recorded to detect self-regulation. The hypothesis of the work was that people who self-regulated would show significantly different results when analyzing their EEG data. Participants were divided into two groups depending on whether Electro Dermal Activity (EDA) data indicated they self-regulated or not. The comparison of the results obtained using different machine learning algorithms for emotion recognition shows that using EEG activity alone as a predictor for self-regulation does

  12. Learning rational temporal eye movement strategies.

    PubMed

    Hoppe, David; Rothkopf, Constantin A

    2016-07-19

    During active behavior humans redirect their gaze several times every second within the visual environment. Where we look within static images is highly efficient, as quantified by computational models of human gaze shifts in visual search and face recognition tasks. However, when we shift gaze is mostly unknown despite its fundamental importance for survival in a dynamic world. It has been suggested that during naturalistic visuomotor behavior gaze deployment is coordinated with task-relevant events, often predictive of future events, and studies in sportsmen suggest that timing of eye movements is learned. Here we establish that humans efficiently learn to adjust the timing of eye movements in response to environmental regularities when monitoring locations in the visual scene to detect probabilistically occurring events. To detect the events humans adopt strategies that can be understood through a computational model that includes perceptual and acting uncertainties, a minimal processing time, and, crucially, the intrinsic costs of gaze behavior. Thus, subjects traded off event detection rate with behavioral costs of carrying out eye movements. Remarkably, based on this rational bounded actor model the time course of learning the gaze strategies is fully explained by an optimal Bayesian learner with humans' characteristic uncertainty in time estimation, the well-known scalar law of biological timing. Taken together, these findings establish that the human visual system is highly efficient in learning temporal regularities in the environment and that it can use these regularities to control the timing of eye movements to detect behaviorally relevant events. PMID:27382164

  13. Self-inflicted eye injuries.

    PubMed Central

    Brown, R; al-Bachari, M A; Kambhampati, K K

    1991-01-01

    Five cases of self-inflicted eye injury are described and discussed. A review of the literature shows that several psychiatric diagnoses have been assigned to people who damage their eyes. A variety of mechanisms to explain this phenomenon are described. PMID:1873272

  14. Miniature curved artificial compound eyes

    PubMed Central

    Floreano, Dario; Pericet-Camara, Ramon; Viollet, Stéphane; Ruffier, Franck; Brückner, Andreas; Leitel, Robert; Buss, Wolfgang; Menouni, Mohsine; Expert, Fabien; Juston, Raphaël; Dobrzynski, Michal Karol; L’Eplattenier, Geraud; Recktenwald, Fabian; Mallot, Hanspeter A.; Franceschini, Nicolas

    2013-01-01

    In most animal species, vision is mediated by compound eyes, which offer lower resolution than vertebrate single-lens eyes, but significantly larger fields of view with negligible distortion and spherical aberration, as well as high temporal resolution in a tiny package. Compound eyes are ideally suited for fast panoramic motion perception. Engineering a miniature artificial compound eye is challenging because it requires accurate alignment of photoreceptive and optical components on a curved surface. Here, we describe a unique design method for biomimetic compound eyes featuring a panoramic, undistorted field of view in a very thin package. The design consists of three planar layers of separately produced arrays, namely, a microlens array, a neuromorphic photodetector array, and a flexible printed circuit board that are stacked, cut, and curved to produce a mechanically flexible imager. Following this method, we have prototyped and characterized an artificial compound eye bearing a hemispherical field of view with embedded and programmable low-power signal processing, high temporal resolution, and local adaptation to illumination. The prototyped artificial compound eye possesses several characteristics similar to the eye of the fruit fly Drosophila and other arthropod species. This design method opens up additional vistas for a broad range of applications in which wide field motion detection is at a premium, such as collision-free navigation of terrestrial and aerospace vehicles, and for the experimental testing of insect vision theories. PMID:23690574

  15. Miniature curved artificial compound eyes.

    PubMed

    Floreano, Dario; Pericet-Camara, Ramon; Viollet, Stéphane; Ruffier, Franck; Brückner, Andreas; Leitel, Robert; Buss, Wolfgang; Menouni, Mohsine; Expert, Fabien; Juston, Raphaël; Dobrzynski, Michal Karol; L'Eplattenier, Geraud; Recktenwald, Fabian; Mallot, Hanspeter A; Franceschini, Nicolas

    2013-06-01

    In most animal species, vision is mediated by compound eyes, which offer lower resolution than vertebrate single-lens eyes, but significantly larger fields of view with negligible distortion and spherical aberration, as well as high temporal resolution in a tiny package. Compound eyes are ideally suited for fast panoramic motion perception. Engineering a miniature artificial compound eye is challenging because it requires accurate alignment of photoreceptive and optical components on a curved surface. Here, we describe a unique design method for biomimetic compound eyes featuring a panoramic, undistorted field of view in a very thin package. The design consists of three planar layers of separately produced arrays, namely, a microlens array, a neuromorphic photodetector array, and a flexible printed circuit board that are stacked, cut, and curved to produce a mechanically flexible imager. Following this method, we have prototyped and characterized an artificial compound eye bearing a hemispherical field of view with embedded and programmable low-power signal processing, high temporal resolution, and local adaptation to illumination. The prototyped artificial compound eye possesses several characteristics similar to the eye of the fruit fly Drosophila and other arthropod species. This design method opens up additional vistas for a broad range of applications in which wide field motion detection is at a premium, such as collision-free navigation of terrestrial and aerospace vehicles, and for the experimental testing of insect vision theories. PMID:23690574

  16. Photographic Screening for Eye Defects

    NASA Technical Reports Server (NTRS)

    Richardson, J.

    1985-01-01

    Images of retinas examined for characteristic patterns. Color photographs of retinas taken. Proper alinement of eye obtained by asking subject to gaze at light-emitting diode. "Red-eye" patterns in resulting color photographs examined by trained observers for signs of ocular defects. System used to check power of contact lenses and eyeglasses by taking photographs with these items in place.

  17. Occupational eye injuries in Finland.

    PubMed

    Saari, K M; Parvi, V

    1984-01-01

    In Finland 11.9% of all industrial accidents in 1973 were eye injuries including superficial eye injuries (79.2%), ultraviolet burns of the cornea (3.9%), eye burns (3.6%), blunt ocular trauma (2,5%), wounds (2.4%), and post-traumatic infections (5.8%). Eye injuries constituted 34.3% of all industrial accidents which needed only ambulatory treatment and 17.5% of all industrial accidents causing an absence for 1-2 days. In 1981 2.1% of all compensated industrial accidents (incapacity for work 3 days or more) were eye injuries. Most compensated eye injuries occurred in manufacturing and in construction work (80.4%) and 8.5% occurred in agriculture. The annual incidence rates of compensated accidents to the eyes (accidents X 1 000/number of employees) were highest in several branches of metal industry (4.96-6.88), excavating and foundation work (6.88), and in logging (5.64). Compensated eye injuries were caused by machines (32.8%), hand tools (25.6%), other equipment and constructions (4.8%), work environment (23.6%), chemical substances (10.8%), and other accidents (2.3%). PMID:6328849

  18. Eye Injuries Can Be Prevented.

    ERIC Educational Resources Information Center

    PTA Today, 1987

    1987-01-01

    Eleven thousand eye injuries are suffered annually by 5- to-14-year-old youngsters during sports and recreational activities. Baseball-related accidents result in more eye injuries to youth than any other sport. Protective face gear is discussed and recommended. (MT)

  19. Dry eye disease after LASIK

    PubMed Central

    Ţuru, L; Alexandrescu, C; Stana, D; Tudosescu, R

    2012-01-01

    LASIK is a surgical tehnique for the correction of refractive errors (myopia, hyperopia, astygmatism). It results in a reshape of the cornea with ocular surface and especially tear film disease. It is a cause for a iatrogenic dry eye syndrome. Neurogenic and inflamatory theory explain this disease. The main therapy of dry eye is the replacement with artificial tears. PMID:22574092

  20. Penetrating eye injury in war.

    PubMed

    Biehl, J W; Valdez, J; Hemady, R K; Steidl, S M; Bourke, D L

    1999-11-01

    The percentage of penetrating eye injuries in war has increased significantly in this century compared with the total number of combat injuries. With the increasing use of fragmentation weapons and possibly laser weapons on the battle-field in the future, the rate of eye injuries may exceed the 13% of the total military injuries found in Operations Desert Storm/Shield. During the Iran-Iraq War (1980-1988), eye injuries revealed that retained foreign bodies and posterior segment injuries have an improved prognosis in future military ophthalmic surgery as a result of modern diagnostic and treatment modalities. Compared with the increasing penetrating eye injuries on the battlefield, advances in ophthalmic surgery are insignificant. Eye armor, such as visors that flip up and down and protect the eyes from laser injury, needs to be developed. Similar eye protection is being developed in civilian sportswear. Penetrating eye injury in the civilian sector is becoming much closer to the military model and is now comparable for several reasons. PMID:10578588

  1. Microoptical telescope compound eye

    NASA Astrophysics Data System (ADS)

    Duparré, Jacques W.; Schreiber, Peter; Matthes, André; Pshenay–Severin, Ekaterina; Bräuer, Andreas; Tünnermann, Andreas; Völkel, Reinhard; Eisner, Martin; Scharf, Toralf

    2005-02-01

    A new optical concept for compact digital image acquisition devices with large field of view is developed and proofed experimentally. Archetypes for the imaging system are compound eyes of small insects and the Gabor Superlens. A paraxial 3x3 matrix formalism is used to describe the telescope arrangement of three microlens arrays with different pitch to find first order parameters of the imaging system. A 2mm thin imaging system with 21x3 channels, 70ºx10º field of view and 4.5mm x 0.5mm image size is optimized and analyzed using sequential and non sequential raytracing and fabricated by microoptics technology. Anamorphic lenses, where the parameters are a function of the considered optical channel, are used to achieve a homogeneous optical performance over the whole field of view. Captured images are presented and compared to simulation results.

  2. Microoptical telescope compound eye.

    PubMed

    Duparré, Jacques; Schreiber, Peter; Matthes, André; Pshenay-Severin, Ekaterina; Bräuer, Andreas; Tünnermann, Andreas; Völkel, Reinhard; Eisner, Martin; Scharf, Toralf

    2005-02-01

    A new optical concept for compact digital image acquisition devices with large field of view is developed and proofed experimentally. Archetypes for the imaging system are compound eyes of small insects and the Gabor-Superlens. A paraxial 3x3 matrix formalism is used to describe the telescope arrangement of three microlens arrays with different pitch to find first order parameters of the imaging system. A 2mm thin imaging system with 21x3 channels, 70 masculinex10 masculine field of view and 4.5mm x 0.5mm image size is optimized and analyzed using sequential and non-sequential raytracing and fabricated by microoptics technology. Anamorphic lenses, where the parameters are a function of the considered optical channel, are used to achieve a homogeneous optical performance over the whole field of view. Captured images are presented and compared to simulation results. PMID:19494951

  3. [Diabetic eye disease].

    PubMed

    Henriques, José; Vaz-Pereira, Sara; Nascimento, João; Rosa, Paulo Caldeira

    2015-01-01

    Diabetes mellitus is a chronic metabolic disease characterized by sustained hyperglycemia leading to macro and microvascular complications. The eye is one of the main organs affected by this disease, being diabetic retinopathy the most well-known microvascular complication and the leading cause of blindness in the working age population. However, diabetic ocular disease is not only characterized by diabetic retinopathy. Other important ocular manifestations of diabetes mellitus include cataract, glaucoma, ischemic optic neuropathy, cranial nerve palsies and recurrent corneal erosion syndrome. Here, we emphasize diabetic retinopathy as the most important and characteristic complication of diabetes mellitus, but also review less well-known complications with the aim to alert and sensitize non-ophthalmologist clinicians that treat diabetic individuals, in order to promote an early diagnosis and treatment of the sight-threatening complications of diabetes. PMID:25817504

  4. Eyes of Ganges

    NASA Technical Reports Server (NTRS)

    2005-01-01

    21 December 2005 This Mars Global Surveyor (MGS) Mars Orbiter Camera (MOC) image shows eroded, light-toned layered rock outcrops on the side of a large mound in Ganges Chasma, part of the vast Valles Marineris trough system. Perhaps a testament to the inherent human (and primate) ability to pick out faces where partially hidden from view (even when a face is not really there) -- near the top of this picture are two features, each a product of erosion, resembling a pair of human eyes. This picture was acquired in late November 2005.

    Location near: 7.1oS, 49.4oW Image width: width: 0.55 km (0.3 mi) Illumination from: left/lower left Season: Southern Summer

  5. Evaluation of the Painful Eye.

    PubMed

    Pflipsen, Matthew; Massaquoi, Mariama; Wolf, Suzanne

    2016-06-15

    Eye problems constitute 2% to 3% of all primary care and emergency department visits. Common eye conditions that can cause eye pain are conjunctivitis, corneal abrasion, and hordeolum, and some of the most serious eye conditions include acute angle-closure glaucoma, orbital cellulitis, and herpetic keratitis. The history should focus on vision changes, foreign body sensation, photophobia, and associated symptoms, such as headache. The physical examination includes an assessment of visual acuity and systematic evaluation of the conjunctiva, eyelids, sclera, cornea, pupil, anterior chamber, and anterior uvea. Further examination with fluorescein staining and tonometry is often necessary. Because eye pain can be the first sign of an ophthalmologic emergency, the physician should determine if referral is warranted. Specific conditions that require ophthalmology consultation include acute angle-closure glaucoma, optic neuritis, orbital cellulitis, scleritis, anterior uveitis, and infectious keratitis. PMID:27304768

  6. "Doctor my eyes": A natural experiment on the demand for eye care services.

    PubMed

    Dickey, H; Ikenwilo, D; Norwood, P; Watson, V; Zangelidis, A

    2016-02-01

    Preventive health care is promoted by many organisations from the World Health Organisation (WHO) to regional and national governments. The degree of cost-sharing between individuals and the health care service affects preventive service use. For instance, out-of-pocket fees that are paid by individuals for curative services reduce preventive care demand. We examine the impact of subsidised preventive care on demand. We motivate our analysis with a theoretical model of inter-temporal substitution in which individuals decide whether to have a health examination in period one and consequently whether to be treated if required in period two. We derive four testable hypotheses. We test these using the subsidised eye care policy introduced in Scotland in 2006. This provides a natural experiment that allows us to identify the effect of the policy on the demand for eye examinations. We also explore socio-economic differences in the response to the policy. The analysis is based on a sample from the British Household Panel Survey of 52,613 observations of people, aged between 16 and 59 years, living in England and Scotland for the period 2001-2008. Using the difference-in-difference methodology, we find that on average the policy did not affect demand for eye examinations. We find that demand for eye examinations only increased among high income households, and consequently, inequalities in eye-care services demand have widened in Scotland since the introduction of the policy. PMID:26745866

  7. Genetics Home Reference: fish-eye disease

    MedlinePlus

    ... Understand Genetics Home Health Conditions fish-eye disease fish-eye disease Enable Javascript to view the expand/ ... boxes. Download PDF Open All Close All Description Fish-eye disease , also called partial LCAT deficiency, is ...

  8. Tamoxifen-Containing Eye Drops Successfully Trigger Cre-Mediated Recombination in the Entire Eye.

    PubMed

    Schlecht, Anja; Leimbeck, Sarah V; Tamm, Ernst R; Braunger, Barbara M

    2016-01-01

    Embryonic lethality in mice with targeted gene deletion is a major issue that can be circumvented by using Cre-loxP-based animal models. Various inducible Cre systems are available, e.g. such that are activated following tamoxifen treatment, and allow deletion of a specific target gene at any desired time point during the life span of the animal. In this study, we describe the efficiency of topical tamoxifen administration by eye drops using a Cre- reporter mouse strain (R26R). We report that tamoxifen-responsive CAGGCre-ER (TM) mice show a robust Cre- mediated recombination throughout the entire eye. PMID:26427451

  9. Eye growth and myopia development: Unifying theory and Matlab model.

    PubMed

    Hung, George K; Mahadas, Kausalendra; Mohammad, Faisal

    2016-03-01

    The aim of this article is to present an updated unifying theory of the mechanisms underlying eye growth and myopia development. A series of model simulation programs were developed to illustrate the mechanism of eye growth regulation and myopia development. Two fundamental processes are presumed to govern the relationship between physiological optics and eye growth: genetically pre-programmed signaling and blur feedback. Cornea/lens is considered to have only a genetically pre-programmed component, whereas eye growth is considered to have both a genetically pre-programmed and a blur feedback component. Moreover, based on the Incremental Retinal-Defocus Theory (IRDT), the rate of change of blur size provides the direction for blur-driven regulation. The various factors affecting eye growth are shown in 5 simulations: (1 - unregulated eye growth): blur feedback is rendered ineffective, as in the case of form deprivation, so there is only genetically pre-programmed eye growth, generally resulting in myopia; (2 - regulated eye growth): blur feedback regulation demonstrates the emmetropization process, with abnormally excessive or reduced eye growth leading to myopia and hyperopia, respectively; (3 - repeated near-far viewing): simulation of large-to-small change in blur size as seen in the accommodative stimulus/response function, and via IRDT as well as nearwork-induced transient myopia (NITM), leading to the development of myopia; (4 - neurochemical bulk flow and diffusion): release of dopamine from the inner plexiform layer of the retina, and the subsequent diffusion and relay of neurochemical cascade show that a decrease in dopamine results in a reduction of proteoglycan synthesis rate, which leads to myopia; (5 - Simulink model): model of genetically pre-programmed signaling and blur feedback components that allows for different input functions to simulate experimental manipulations that result in hyperopia, emmetropia, and myopia. These model simulation programs

  10. Core-shell GaN-ZnO moth-eye nanostructure arrays grown on a-SiO2/Si (1 1 1) as a basis for improved InGaN-based photovoltaics and LEDs

    NASA Astrophysics Data System (ADS)

    Rogers, D. J.; Sandana, V. E.; Gautier, S.; Moudakir, T.; Abid, M.; Ougazzaden, A.; Teherani, F. Hosseini; Bove, P.; Molinari, M.; Troyon, M.; Peres, M.; Soares, Manuel J.; Neves, A. J.; Monteiro, T.; McGrouther, D.; Chapman, J. N.; Drouhin, H.-J.; McClintock, R.; Razeghi, M.

    2015-06-01

    Self-forming, vertically-aligned, ZnO moth-eye-like nanoarrays were grown by catalyst-free pulsed laser deposition on a-SiO2/Si (1 1 1) substrates. X-Ray Diffraction (XRD) and Cathodoluminescence (CL) studies indicated that nanostructures were highly c-axis oriented wurtzite ZnO with strong near band edge emission. The nanostructures were used as templates for the growth of non-polar GaN by metal organic vapor phase epitaxy. XRD, scanning electron microscopy, energy dispersive X-ray microanalysis and CL revealed ZnO encapsulated with GaN, without evidence of ZnO back-etching. XRD showed compressive epitaxial strain in the GaN, which is conducive to stabilization of the higher indium contents required for more efficient green light emitting diode (LED) and photovoltaic (PV) operation. Angular-dependent specular reflection measurements showed a relative reflectance of less than 1% over the wavelength range of 400-720 nm at all angles up to 60°. The superior black-body performance of this moth-eye-like structure would boost LED light extraction and PV anti-reflection performance compared with existing planar or nanowire LED and PV morphologies. The enhancement in core conductivity, provided by the ZnO, would also improve current distribution and increase the effective junction area compared with nanowire devices based solely on GaN.

  11. The eye and its diseases in Ancient Egypt.

    PubMed

    Andersen, S R

    1997-06-01

    Based on a study of mummies, skeletons, burial rites, medical instruments, medicaments, literature and objets d'art from Ancient Egypt before the Hellenistic Period, the understanding of the eye, its diseases and their treatment at that time is described. Magic spells, religious rites and medical treatments, especially with eye ointments, were probably used often complementary to one another. We must be very cautious about our conclusions in regard to the effectiveness of the treatments. Eye diseases have been depicted only exceptionally in Egyptian art, except for blindness and 'symbolic blindness'. PMID:9253993

  12. Arousal facilitates involuntary eye movements.

    PubMed

    DiGirolamo, Gregory J; Patel, Neha; Blaukopf, Clare L

    2016-07-01

    Attention plays a critical role in action selection. However, the role of attention in eye movements is complicated as these movements can be either voluntary or involuntary, with, in some circumstances (antisaccades), these two actions competing with each other for execution. But attending to the location of an impending eye movement is only one facet of attention that may play a role in eye movement selection. In two experiments, we investigated the effect of arousal on voluntary eye movements (antisaccades) and involuntary eye movements (prosaccadic errors) in an antisaccade task. Arousal, as caused by brief loud sounds and indexed by changes in pupil diameter, had a facilitation effect on involuntary eye movements. Involuntary eye movements were both significantly more likely to be executed and significantly faster under arousal conditions (Experiments 1 and 2), and the influence of arousal had a specific time course (Experiment 2). Arousal, one form of attention, can produce significant costs for human movement selection as potent but unplanned actions are benefited more than planned ones. PMID:26928432

  13. Biomimetic artificial Si compound eye surface structures with broadband and wide-angle antireflection properties for Si-based optoelectronic applications

    NASA Astrophysics Data System (ADS)

    Leem, Jung Woo; Song, Young Min; Yu, Jae Su

    2013-10-01

    We report the biomimetic artificial silicon (Si) compound eye structures for broadband and wide-angle antireflection by integrating nanostructures (NSs) into periodically patterned microstructures (p-MSs) via thermal dewetting of gold and subsequent dry etching. The truncated cone microstructures with a two-dimensional hexagonal symmetry pattern were fabricated by photolithography and dry etching processes. The desirable shape and density of the nanostructures were obtained by controlled dewetting. The incorporation of p-MSs into the NS/Si surface further reduced the surface total reflectance over a wide wavelength range of 300-1030 nm at near normal incidence, indicating the average reflectance (Ravg) and solar weighted reflectance (RSWR) values of ~2.5% and 2%, respectively, compared to the only NSs on the flat Si surface (i.e., Ravg ~ 4.9% and RSWR ~ 4.5%). Additionally, the resulting structure improved the angle-dependent antireflection property due to its relatively omnidirectional shape, which exhibited the Ravg < 4.3% and RSWR < 3.7% in the wavelength region of 300-1100 nm even at a high incident light angle of 70° in the specular reflectance.We report the biomimetic artificial silicon (Si) compound eye structures for broadband and wide-angle antireflection by integrating nanostructures (NSs) into periodically patterned microstructures (p-MSs) via thermal dewetting of gold and subsequent dry etching. The truncated cone microstructures with a two-dimensional hexagonal symmetry pattern were fabricated by photolithography and dry etching processes. The desirable shape and density of the nanostructures were obtained by controlled dewetting. The incorporation of p-MSs into the NS/Si surface further reduced the surface total reflectance over a wide wavelength range of 300-1030 nm at near normal incidence, indicating the average reflectance (Ravg) and solar weighted reflectance (RSWR) values of ~2.5% and 2%, respectively, compared to the only NSs on the flat Si

  14. [Eye Myiasis - a Case Report].

    PubMed

    Kopecký, A; Němčanský, J; Doležil, Z; Mašková, R; Mašek, P

    2015-09-01

    The authors describe a case of 47 years old patient who came to the department of ophthalmology with eye discomfort, ear bleeding and itching of both legs. The diagnosis of ophthalmomyiasis was made after an eye examination. Manual extraction of maggots from upper and lower fornix of the left eye was performed and symptomatic therapy was given. The patient was sent to otolaryngology and dermatology departments and MRI. The maggots were also found in both external auditory meatus and between the toes. MRI excluded affection of the deeper structures of the head. Improvement of the local condition was observed since the first follow-up visit. PMID:26782730

  15. 'By seeing with our own eyes, it can remain in our mind': qualitative evaluation findings suggest the ability of participatory video to reduce gender-based violence in conflict-affected settings.

    PubMed

    Gurman, Tilly A; Trappler, Regan M; Acosta, Angela; McCray, Pamella A; Cooper, Chelsea M; Goodsmith, Lauren

    2014-08-01

    Gender-based violence is pervasive and poses unique challenges in conflict-affected settings, with women and girls particularly vulnerable to its sequelae. Furthermore, widespread stigmatization of gender-based violence promotes silence among survivors and families, inhibiting access to services. Little evidence exists regarding effective gender-based violence prevention interventions in these settings. Through Our Eyes, a multi-year participatory video project, addressed gender-based violence by stimulating community dialogue and action in post-conflict settings in South Sudan, Uganda, Thailand, Liberia and Rwanda. The present qualitative analysis of project evaluation data included transcripts from 18 focus group discussions (n = 125) and key informant interviews (n = 76). Study participants included project team members, representatives from partner agencies, service providers and community members who either participated in video production or attended video screenings. Study findings revealed that the video project contributed to a growing awareness of women's rights and gender equality. The community dialogue helped to begin dismantling the culture of silence gender-based violence, encouraging survivors to access health and law enforcement services. Furthermore, both men and women reported attitude and behavioral changes related to topics such as wife beating, gender-based violence reporting and girls' education. Health education professionals should employ participatory video to address gender-based violence within conflict-affected settings. PMID:24973224

  16. The Prevalence of Dry Eye Syndrome’s and the Likelihood to Develop Sjögren’s Syndrome in Taiwan: A Population-Based Study

    PubMed Central

    Yen, Ju-Chuan; Hsu, Chia-An; Li, Yu-Chuan (Jack); Hsu, Min-Huei

    2015-01-01

    Background: Dry eye syndrome (DES) is one of the key clinical features and possibly an early clinical presentation of Sjögren’s syndrome (SS). We explore DES prevalence and assess the likelihood of DES patients to develop SS in Taiwan through the National Health Insurance Research Database (NHIRD). Methods: Through a cohort comparison study, longitudinal data from the NHIRD (2000 to 2008) in Taiwan was used to probe the prevalence of DES and the odds that DES patients would later develop SS. Results: The prevalence of DES in the present study is 4.87%. The incidence rates of developing SS were 4.8% for the DES group and 1.5% for comparison group. The median age and interquartile range of DES and comparison patients was 49.8 (10) and 48.7 (15) years old, respectively. The crude hazard ratio (with 95% confidence interval) for DES patients to develop SS was 3.13 (3.10–3.50) for the DES group, and the adjusted hazard ratio (with 95% confidence interval) was 3.64 (3.43–3.87). The observation period and interquartile range for DES and comparison patients to develop SS later were 1418 (781–2316) versus 1641 (971–2512) days respectively. Conclusions: DES patients carried a higher risk for developing SS (hazard ratio 3.13) and presented for SS 3.88 years earlier than comparison group patients in this study. PMID:26184245

  17. Eyes in the Sky

    NASA Technical Reports Server (NTRS)

    2006-01-01

    These shape-shifting galaxies have taken on the form of a giant mask. The icy blue eyes are actually the cores of two merging galaxies, called NGC 2207 and IC 2163, and the mask is their spiral arms. The false-colored image consists of infrared data from NASA's Spitzer Space Telescope (red) and visible data from NASA's Hubble Space Telescope (blue/green).

    NGC 2207 and IC 2163 met and began a sort of gravitational tango about 40 million years ago. The two galaxies are tugging at each other, stimulating new stars to form. Eventually, this cosmic ball will come to an end, when the galaxies meld into one. The dancing duo is located 140 million light-years away in the Canis Major constellation.

    The infrared data from Spitzer highlight the galaxies' dusty regions, while the visible data from Hubble indicates starlight. In the Hubble-only image (not pictured here), the dusty regions appear as dark lanes.

    The Hubble data correspond to light with wavelengths of .44 and .55 microns (blue and green, respectively). The Spitzer data represent light of 8 microns.

  18. The eyes of LITENING

    NASA Astrophysics Data System (ADS)

    Moser, Eric K.

    2016-05-01

    LITENING is an airborne system-of-systems providing long-range imaging, targeting, situational awareness, target tracking, weapon guidance, and damage assessment, incorporating a laser designator and laser range finders, as well as non-thermal and thermal imaging systems, with multi-sensor boresight. Robust operation is at a premium, and subsystems are partitioned to modular, swappable line-replaceable-units (LRUs) and shop-replaceable-units (SRUs). This presentation will explore design concepts for sensing, data storage, and presentation of imagery associated with the LITENING targeting pod. The "eyes" of LITENING are the electro-optic sensors. Since the initial LITENING II introduction to the US market in the late 90s, as the program has evolved and matured, a series of spiral functional improvements and sensor upgrades have been incorporated. These include laser-illuminated imaging, and more recently, color sensing. While aircraft displays are outside of the LITENING system, updates to the available viewing modules have also driven change, and resulted in increasingly effective ways of utilizing the targeting system. One of the latest LITENING spiral upgrades adds a new capability to display and capture visible-band color imagery, using new sensors. This is an augmentation to the system's existing capabilities, which operate over a growing set of visible and invisible colors, infrared bands, and laser line wavelengths. A COTS visible-band camera solution using a CMOS sensor has been adapted to meet the particular needs associated with the airborne targeting use case.

  19. Visible-spectrum remote eye tracker for gaze communication

    NASA Astrophysics Data System (ADS)

    Imabuchi, Takashi; Prima, Oky Dicky A.; Kikuchi, Hikaru; Horie, Yusuke; Ito, Hisayoshi

    2015-03-01

    Many approaches have been proposed to create an eye tracker based on visible-spectrum. These efforts provide a possibility to create inexpensive eye tracker capable to operate outdoor. Although the resulted tracking accuracy is acceptable for a visible-spectrum head-mounted eye tracker, there are many limitations of these approaches to create a remote eye tracker. In this study, we propose a high-accuracy remote eye tracker that uses visible-spectrum imaging and several gaze communication interfaces suited to the tracker. The gaze communication interfaces are designed to assist people with motor disability. Our results show that the proposed eye tracker achieved an average accuracy of 0.77° and a frame rate of 28 fps with a personal computer. With a tablet device, the proposed eye tracker achieved an average accuracy of 0.82° and a frame rate of 25 fps. The proposed gaze communication interfaces enable users to type a complete sentence containing eleven Japanese characters in about a minute.

  20. Arthropod eye-inspired digital camera with unique imaging characteristics

    NASA Astrophysics Data System (ADS)

    Xiao, Jianliang; Song, Young Min; Xie, Yizhu; Malyarchuk, Viktor; Jung, Inhwa; Choi, Ki-Joong; Liu, Zhuangjian; Park, Hyunsung; Lu, Chaofeng; Kim, Rak-Hwan; Li, Rui; Crozier, Kenneth B.; Huang, Yonggang; Rogers, John A.

    2014-06-01

    In nature, arthropods have a remarkably sophisticated class of imaging systems, with a hemispherical geometry, a wideangle field of view, low aberrations, high acuity to motion and an infinite depth of field. There are great interests in building systems with similar geometries and properties due to numerous potential applications. However, the established semiconductor sensor technologies and optics are essentially planar, which experience great challenges in building such systems with hemispherical, compound apposition layouts. With the recent advancement of stretchable optoelectronics, we have successfully developed strategies to build a fully functional artificial apposition compound eye camera by combining optics, materials and mechanics principles. The strategies start with fabricating stretchable arrays of thin silicon photodetectors and elastomeric optical elements in planar geometries, which are then precisely aligned and integrated, and elastically transformed to hemispherical shapes. This imaging device demonstrates nearly full hemispherical shape (about 160 degrees), with densely packed artificial ommatidia. The number of ommatidia (180) is comparable to those of the eyes of fire ants and bark beetles. We have illustrated key features of operation of compound eyes through experimental imaging results and quantitative ray-tracing-based simulations. The general strategies shown in this development could be applicable to other compound eye devices, such as those inspired by moths and lacewings (refracting superposition eyes), lobster and shrimp (reflecting superposition eyes), and houseflies (neural superposition eyes).

  1. Interactive Interface with Evolutionary Eye Sensing and Physiological Knowledge

    NASA Astrophysics Data System (ADS)

    Akashi, Takuya; Wakasa, Yuji; Tanaka, Kanya; Karungaru, Stephen; Fukumi, Minoru

    The purpose of this study is to develop an interactive interface using eye movement to operate a welfare apparatus, such as a feeding device for an orthopedically-impaired person. A part of the purpose is to eliminate special calibration and re-calibration during the operation. Originalities of this proposed system are as follows: eye sensing with evolutionary processing and interactive operation screen based on some physiological knowledge. The proposed system uses a non-contact type interface by the eye movement. An iris is tracked and eye movement is measured by the evolutionary eye sensing (EES) method. An operation screen is divided into 9 areas, which has visual stimulation using the physiological knowledge. A user can select these areas by eye movement and decide by eye fixation. The effectiveness of the proposed system is evaluated by comparison experiments with 20 subjects. The results indicate that the proposed system is easy to use for first-timer, who can become proficient in operation just after a few exercises.

  2. Absorbed dose behind eye shields during kilovoltage photon radiotherapy.

    PubMed

    Baker, C R; Luhana, F; Thomas, S J

    2002-08-01

    The absorbed dose at the position of the lens of the eye under lead or tungsten eye shields during kilovoltage photon radiotherapy is critically dependent not so much on the thickness of the eye shield itself as on the size of the treatment field and the diameter of the shield used. Whilst dose from primary photons is easily attenuated to relatively insignificant levels by a few millimetres of lead or tungsten, scattered photons from outside the shielded area can provide over 25% of the prescribed dose. Since backscatter factors do not increase monotonically with photon energy, it is not safe to assume that the highest photon energy used will provide the highest dose. A simple method to estimate the dose under an eye shield based on tabulated backscatter factors is shown. Measurements under commercially available eye shields were made to verify the expression and to determine the attenuation of primary photons. Predicted and measured absorbed dose under the eye shields were found to agree to within 1% of the prescribed dose. The relative dose due to primary photons beneath the eye shields was found to be less than 0.1% and 0.5 (+/-0.1)% for the 150 kV and 260 kV beams, respectively. This is considerably less than the dose from backscattered radiation. PMID:12153943

  3. Nutrition and the Aging Eye

    MedlinePlus

    ... of this page please turn Javascript on. Feature: Vision Nutrition and the Aging Eye Past Issues / Winter ... related macular degeneration (AMD), the leading cause of vision loss for people over 60. But new research ...

  4. Childhood Eye Diseases and Conditions

    MedlinePlus

    ... and Conditions Nov. 01, 2013 The importance of vision screening There are many eye conditions and diseases ... child’s vision. Focus and alignment disorders that affect vision If any of the following conditions is suspected, ...

  5. Conjunctivitis (Pink Eye) in Newborns

    MedlinePlus

    ... Antibiotics Work Adenovirus Non-Polio Enterovirus Parent Portal Conjunctivitis (Pink Eye) in Newborns Language: English Español (Spanish) ... can be very serious. Symptoms and Causes of Conjunctivitis in Newborns Newborns with conjunctivitis develop drainage from ...

  6. Eye movements when viewing advertisements

    PubMed Central

    Higgins, Emily; Leinenger, Mallorie; Rayner, Keith

    2013-01-01

    In this selective review, we examine key findings on eye movements when viewing advertisements. We begin with a brief, general introduction to the properties and neural underpinnings of saccadic eye movements. Next, we provide an overview of eye movement behavior during reading, scene perception, and visual search, since each of these activities is, at various times, involved in viewing ads. We then review the literature on eye movements when viewing print ads and warning labels (of the kind that appear on alcohol and tobacco ads), before turning to a consideration of advertisements in dynamic media (television and the Internet). Finally, we propose topics and methodological approaches that may prove to be useful in future research. PMID:24672500

  7. Genetic Testing and Eye Disease

    MedlinePlus

    ... a History of Eye Disease, Do You Need Genetic Testing? Mar. 23, 2012 Thanks to news coverage, ... of breast or ovarian cancer. Physicians now use genetic tests to decide on treatment for some types ...

  8. Applications of lobster eye optics

    NASA Astrophysics Data System (ADS)

    Hudec, R.; Pina, L.; Inneman, A.; Tichy, V.

    2015-05-01

    Applications of wide field Lobster Eye X ray telescopes are presented and discussed. The wide field X ray optics was originally proposed for use in X-ray astronomy, but there are numerous other application areas as well.

  9. Desperate for Shut-Eye?

    MedlinePlus

    ... html Desperate for Shut-Eye? Physicians' group recommends cognitive behavioral therapy before drugs for insomnia To use the sharing ... recommends. Specifically, people with chronic insomnia should try cognitive behavioral therapy (CBT), the experts said. This treatment combines talk ...

  10. Eye movements when viewing advertisements.

    PubMed

    Higgins, Emily; Leinenger, Mallorie; Rayner, Keith

    2014-01-01

    In this selective review, we examine key findings on eye movements when viewing advertisements. We begin with a brief, general introduction to the properties and neural underpinnings of saccadic eye movements. Next, we provide an overview of eye movement behavior during reading, scene perception, and visual search, since each of these activities is, at various times, involved in viewing ads. We then review the literature on eye movements when viewing print ads and warning labels (of the kind that appear on alcohol and tobacco ads), before turning to a consideration of advertisements in dynamic media (television and the Internet). Finally, we propose topics and methodological approaches that may prove to be useful in future research. PMID:24672500

  11. Human eye color difference threshold measurement system

    NASA Astrophysics Data System (ADS)

    Liu, Lin; Zhou, Taogeng

    2013-12-01

    The human eye has the ability to distinguish millions of colors, with this feature we can identify very subtle color differences, and the measurement of human eye color difference threshold can provide a visual function diagnosis for testee. In recent years, people begin to focus on studies on visual threshold diagnostic equipment. This paper proposes a human eye color difference threshold measurement system which is based on dual integrating sphere. The system includes two pairs of dual integrating sphere and color control module. Dual integrating sphere uses to mix and produce color, and palette unit which produces primary colors (red (R), green (G), blue (B)) is embedded in dual integrating sphere. At the same time, the embedded palette unit which produces cyan (C), magenta (M), and yellow (Y) expands color area that the system can generate. One optical path based on dual integrating sphere generates standard color, the other path produces the matching color which is similar to a standard color. In the high-precision closed-loop color control module, photoelectric switch records stepper motor's origin position and limits move displacement. Precision stepper motor pushes the light-blocking panel of the palette unit to a predetermined position, while real-time monitoring the position of the light-blocking panel and mixing the ideal controllable color. Two colors that the system generates are projected onto the same target area. Subjects make a judgment on color difference threshold by observing the target eventually.

  12. Eye gaze tracking using correlation filters

    NASA Astrophysics Data System (ADS)

    Karakaya, Mahmut; Bolme, David; Boehnen, Chris

    2014-03-01

    In this paper, we studied a method for eye gaze tracking that provide gaze estimation from a standard webcam with a zoom lens and reduce the setup and calibration requirements for new users. Specifically, we have developed a gaze estimation method based on the relative locations of points on the top of the eyelid and eye corners. Gaze estimation method in this paper is based on the distances between top point of the eyelid and eye corner detected by the correlation filters. Advanced correlation filters were found to provide facial landmark detections that are accurate enough to determine the subjects gaze direction up to angle of approximately 4-5 degrees although calibration errors often produce a larger overall shift in the estimates. This is approximately a circle of diameter 2 inches for a screen that is arm's length from the subject. At this accuracy it is possible to figure out what regions of text or images the subject is looking but it falls short of being able to determine which word the subject has looked at.

  13. Eye Gaze Tracking using Correlation Filters

    SciTech Connect

    Karakaya, Mahmut; Boehnen, Chris Bensing; Bolme, David S; Mahallesi, Mevlana; Kayseri, Talas

    2014-01-01

    In this paper, we studied a method for eye gaze tracking that provide gaze estimation from a standard webcam with a zoom lens and reduce the setup and calibration requirements for new users. Specifically, we have developed a gaze estimation method based on the relative locations of points on the top of the eyelid and eye corners. Gaze estimation method in this paper is based on the distances between top point of the eyelid and eye corner detected by the correlation filters. Advanced correlation filters were found to provide facial landmark detections that are accurate enough to determine the subjects gaze direction up to angle of approximately 4-5 degrees although calibration errors often produce a larger overall shift in the estimates. This is approximately a circle of diameter 2 inches for a screen that is arm s length from the subject. At this accuracy it is possible to figure out what regions of text or images the subject is looking but it falls short of being able to determine which word the subject has looked at.

  14. Electroporation of Embryonic Chick Eyes

    PubMed Central

    Luz-Madrigal, Agustín; Grajales-Esquivel, Erika; Del Rio-Tsonis, Katia

    2016-01-01

    The chick embryo has prevailed as one of the major models to study developmental biology, cell biology and regeneration. From all the anatomical features of the chick embryo, the eye is one of the most studied. In the chick embryo, the eye develops between 26 and 33 h after incubation (Stages 8–9, Hamburger and Hamilton, 1951). It originates from the posterior region of the forebrain, called the diencephalon. However, the vertebrate eye includes tissues from different origins including surface ectoderm (lens and cornea), anterior neural plate (retina, iris, ciliary body and retinal pigmented epithelium) and neural crest/head mesoderm (stroma of the iris and of the ciliary body as well as choroid, sclera and part of the cornea). After gastrulation, a single eye field originates from the anterior neural plate and is characterized by the expression of eye field transcriptional factors (EFTFs) that orchestrate the program for eye development. Later in development, the eye field separates in two and the optic vesicles form. After several inductive interactions with the lens placode, the optic cup forms. At Stages 14–15, the outer layer of the optic cup becomes the retinal pigmented epithelium (RPE) while the inner layer forms the neuroepithelium that eventually differentiates into the retina. One main advantage of the chick embryo, is the possibility to perform experiments to over-express or to down-regulate gene expression in a place and time specific manner to explore gene function and regulation. The aim of this protocol is to describe the electroporation techniques at Stages 8–12 (anterior neural fold and optic vesicle stages) and Stages 19–26 (eye cup, RPE and neuroepithelium). We provide a full description of the equipment, materials and electrode set up as well as a detailed description of the highly reproducible protocol including some representative results. This protocol has been adapted from our previous publications Luz-Madrigal et al. (2014) and Zhu

  15. Eye-voice-controlled interface

    NASA Technical Reports Server (NTRS)

    Glenn, Floyd A., III; Iavecchia, Helene P.; Ross, Lorna V.; Stokes, James M.; Weiland, William J.

    1986-01-01

    The Ocular Attention-Sensing Interface System (OASIS) is an innovative human-computer interface which utilizes eye movement and voice commands to communicate messages between the operator and the system. This report initially describes some technical issues relevant to the development of such an interface. The results of preliminary experiments which evaluate alternative eye processing algorithms and feedback techniques are presented. Candidate interface applications are also discussed.

  16. Eye complaints in the office environment: precorneal tear film integrity influenced by eye blinking efficiency.

    PubMed

    Wolkoff, P; Nøjgaard, J K; Troiano, P; Piccoli, B

    2005-01-01

    To achieve a common base for understanding work related eye complaints in the office environment, it is necessary to merge approaches from indoor air science, occupational health, and ophthalmology. Based on database searches, it is concluded that precorneal tear film (PTF) alteration leads to eye complaints that may be caused by: (1) thermal factors (low relative humidity; high room temperature); (2) demanding task content (attention decreases blinking and widens the exposed ocular surface area); and (3) individual characteristics (for example, tear film alterations, blinking anomalies, gland dysfunctions, and use of contact lenses). These factors and conditions are able to progressively increase water evaporation and faster thinning of the PTF, which causes dryness and dry spot formation on the cornea, possibly followed by corneal and conjunctiva epithelial alterations and eye complaints. Another possible cause of eye complaints is certain irritating chemical compounds, in addition to oxidation mixtures that are formed in reactions between ozone and unsaturated organic compounds (alkenes). The effect may be exacerbated by low relative humidity. PMID:15613602

  17. Treatment of chronic dry eye: focus on cyclosporine

    PubMed Central

    Kymionis, George D; Bouzoukis, Dimitrios I; Diakonis, Vassilios F; Siganos, Charalambos

    2008-01-01

    To review the current treatment of chronic dry eye syndrome, focusing on cyclosporine A (CsA), a systematic literature search was performed using PubMed databases in two steps. The first step was oriented to articles published for dry eye. The second step was focused on the use of CsA in dry eye. A manual literature search was also undertaken based on citations in the published articles. The knowledge on the pathogenesis of dry eye syndrome has changed dramatically during the last few years. Inflammation and the interruption of the inflammatory cascade seem to be the main focus of the ophthalmologic community in the treatment of dry eye, giving the anti-inflammatory therapy a new critical role. The infiltration of T-cells in the conjuctiva tissue and the presence of cytokines and proteasis in the tear fluid were the main reason introducing the use of immunomodulator agents such as corticosteroids, cyclosporine, and doxycicline in order to treat dry eye syndrome. CsA emulsion is approved by the FDA for the treatment of dry eye, while clinical trials of this agent have demonstrated efficacy and safety of CsA. CsA seems to be a promising treatment against dry eye disease. New agents focused on the inflammatory pathogenesis of this syndrome in combination with CsA may be the future in the quest of treating dry eye. More studies are needed to determine the efficacy, safety, timing, and relative cost/effect of CsA. PMID:19668437

  18. A new amplicon based approach of whole mitogenome sequencing for phylogenetic and phylogeographic analysis: An example of East African white-eyes (Aves, Zosteropidae).

    PubMed

    Meimberg, Harald; Schachtler, Christina; Curto, Manuel; Husemann, Martin; Habel, Jan Christian

    2016-09-01

    Classical Sanger sequencing is still frequently used to generate sequence data for phylogenetic and phylogeographic inference. In this contribution we present a novel approach to genotype whole mitogenomic haplotypes using Illumina MiSeq reads from indexed amplicons. Our new approach reduces preparation time by multiplexing loci within a single or few PCR reactions and by plate format library construction. The use of paired-end reads allows covering amplicons of about 0.5kb and thus no nebulisation and assembly are necessary. We tested the power and effectiveness of this technique by analysing the mitogenomic diversity of East African white-eye bird species (Zosteropidae), a taxonomically highly diverse and complex species flock found in various ecosystems spread across major parts of Africa. We compare the newly generated mitogenomic data set with published data of three mitochondrial genes for a similar set of populations and taxa. The comparison demonstrates that our new procedure represents a cost effective use of NGS for medium throughput phylogenetic analyses. Using this method, we were able to increase the amount of phylogenetic information significantly, while reducing the costs and effort in the laboratory. The mitogenomic data show a higher resolution than previous studies providing higher support and new insights in the relationships of Zosterops species. Our data suggest to split Z. poliogaster into four distinct species, three of which had previously been proposed: Z. silvanus, Z. mbulensis, Z. kikyuensis and Z. kulalensis. Our approach allows the genotyping of whole mitogenomes for a large number of individuals and thus allows more reliable reconstruction of phylogenetic and phylogeographic relationships - also for non-model organisms. PMID:27233440

  19. The Cat's Eye Nebula

    NASA Technical Reports Server (NTRS)

    1994-01-01

    This NASA Hubble Space Telescope image shows one of the most complex planetary nebulae ever seen, NGC 6543, nicknamed the 'Cat's Eye Nebula.' Hubble reveals surprisingly intricate structures including concentric gas shells, jets of high-speed gas and unusual shock-induced knots of gas. Estimated to be 1,000 years old, the nebula is a visual 'fossil record' of the dynamics and late evolution of a dying star. A preliminary interpretation suggests that the star might be a double-star system. The suspected companion star also might be responsible for a pair of high-speed jets of gas that lie at right angles to this equatorial ring. If the companion were pulling in material from a neighboring star, jets escaping along the companion's rotation axis could be produced. These jets would explain several puzzling features along the periphery of the gas lobes. Like a stream of water hitting a sand pile, the jets compress gas ahead of them, creating the 'curlicue' features and bright arcs near the outer edge of the lobes. The twin jets are now pointing in different directions than these features. This suggests the jets are wobbling, or precessing, and turning on and off episodically. This color picture, taken with the Wide Field Planetary Camera-2, is a composite of three images taken at different wavelengths. (red, hydrogen-alpha; blue, neutral oxygen, 6300 angstroms; green, ionized nitrogen, 6584 angstroms). The image was taken on September 18, 1994. NGC 6543 is 3,000 light- years away in the northern constellation Draco. The term planetary nebula is a misnomer; dying stars create these cocoons when they lose outer layers of gas. The process has nothing to do with planet formation, which is predicted to happen early in a star's life.

  20. Eye Movements in Risky Choice

    PubMed Central

    Hermens, Frouke; Matthews, William J.

    2015-01-01

    Abstract We asked participants to make simple risky choices while we recorded their eye movements. We built a complete statistical model of the eye movements and found very little systematic variation in eye movements over the time course of a choice or across the different choices. The only exceptions were finding more (of the same) eye movements when choice options were similar, and an emerging gaze bias in which people looked more at the gamble they ultimately chose. These findings are inconsistent with prospect theory, the priority heuristic, or decision field theory. However, the eye movements made during a choice have a large relationship with the final choice, and this is mostly independent from the contribution of the actual attribute values in the choice options. That is, eye movements tell us not just about the processing of attribute values but also are independently associated with choice. The pattern is simple—people choose the gamble they look at more often, independently of the actual numbers they see—and this pattern is simpler than predicted by decision field theory, decision by sampling, and the parallel constraint satisfaction model. © 2015 The Authors. Journal of Behavioral Decision Making published by John Wiley & Sons Ltd. PMID:27522985

  1. Simulation of Ametropic Human Eyes

    NASA Astrophysics Data System (ADS)

    Tan, Bo; Chen, Ying-Ling; Lewis, James W. L.

    2004-11-01

    The computational simulation of the performance of human eyes is complex because the optical parameters of the eye depend on many factors, including age, gender, race, refractive status (accommodation and near- or far-sightedness). This task is made more difficult by the inadequacy of the population statistical characteristics of these parameters. Previously we simulated ametropic (near- or far-sighted) eyes using three independent variables: the axial length of the eye, the corneal surface curvature, and the intraocular refractive index gradient. The prescription for the correction of an ametropic eye is determined by its second-order coefficients of the wavefront aberrations. These corrections are typically achieved using contact lens, spectacle lens, or laser surgery (LASIK). However, the higher order aberrations, which are not corrected and are likely complicated or enhanced by the lower-order correction, could be important for visual performance in a darkened environment. In this paper, we investigate the higher order wavefront aberrations of synthetic ametropic eyes and compare results with measured data published in the past decade. The behavior of three types of ametropes is discussed.

  2. Eye casualty services in London

    PubMed Central

    Smith, H B; Daniel, C S; Verma, S

    2013-01-01

    The combined pressures of the European Working Time Directive, 4 h waiting time target, and growing rates of unplanned hospital attendances have forced a major consolidation of eye casualty departments across the country, with the remaining units seeing a rapid increase in demand. We examine the effect of these changes on the provision of emergency eye care in Central London, and see what wider lessons can be learned. We surveyed the managers responsible for each of London's 8 out-of-hours eye casualty services, analysed data on attendance numbers, and conducted detailed interviews with lead clinicians. At London's two largest units, Moorfields Eye Hospital and the Western Eye Hospital, annual attendance numbers have been rising at 7.9% per year (to 76 034 patients in 2010/11) and 9.6% per year (to 31 128 patients in 2010/11), respectively. Using Moorfields as a case study, we discuss methods to increase capacity and efficiency in response to this demand, and also examine some of the unintended consequences of service consolidation including patients travelling long distances to geographically inappropriate units, and confusion over responsibility for out-of-hours inpatient cover. We describe a novel ‘referral pathway' developed to minimise unnecessary travelling and delay for patients, and propose a forum for the strategic planning of London's eye casualty services in the future. PMID:23370420

  3. What's on TV? Detecting age-related neurodegenerative eye disease using eye movement scanpaths

    PubMed Central

    Crabb, David P.; Smith, Nicholas D.; Zhu, Haogang

    2014-01-01

    Purpose: We test the hypothesis that age-related neurodegenerative eye disease can be detected by examining patterns of eye movement recorded whilst a person naturally watches a movie. Methods: Thirty-two elderly people with healthy vision (median age: 70, interquartile range [IQR] 64–75 years) and 44 patients with a clinical diagnosis of glaucoma (median age: 69, IQR 63–77 years) had standard vision examinations including automated perimetry. Disease severity was measured using a standard clinical measure (visual field mean deviation; MD). All study participants viewed three unmodified TV and film clips on a computer set up incorporating the Eyelink 1000 eyetracker (SR Research, Ontario, Canada). Eye movement scanpaths were plotted using novel methods that first filtered the data and then generated saccade density maps. Maps were then subjected to a feature extraction analysis using kernel principal component analysis (KPCA). Features from the KPCA were then classified using a standard machine based classifier trained and tested by a 10-fold cross validation which was repeated 100 times to estimate the confidence interval (CI) of classification sensitivity and specificity. Results: Patients had a range of disease severity from early to advanced (median [IQR] right eye and left eye MD was −7 [−13 to −5] dB and −9 [−15 to −4] dB, respectively). Average sensitivity for correctly identifying a glaucoma patient at a fixed specificity of 90% was 79% (95% CI: 58–86%). The area under the Receiver Operating Characteristic curve was 0.84 (95% CI: 0.82–0.87). Conclusions: Huge data from scanpaths of eye movements recorded whilst people freely watch TV type films can be processed into maps that contain a signature of vision loss. In this proof of principle study we have demonstrated that a group of patients with age-related neurodegenerative eye disease can be reasonably well separated from a group of healthy peers by considering these eye movement

  4. 14 CFR 67.303 - Eye.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 2 2011-01-01 2011-01-01 false Eye. 67.303 Section 67.303 Aeronautics and... AND CERTIFICATION Third-Class Airman Medical Certificate § 67.303 Eye. Eye standards for a third-class airman medical certificate are: (a) Distant visual acuity of 20/40 or better in each eye separately,...

  5. 21 CFR 878.4440 - Eye pad.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Eye pad. 878.4440 Section 878.4440 Food and Drugs... GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4440 Eye pad. (a) Identification. An eye pad is... use as a bandage over the eye for protection or absorption of secretions. (b) Classification. Class...

  6. 21 CFR 886.3200 - Artificial eye.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Artificial eye. 886.3200 Section 886.3200 Food and... OPHTHALMIC DEVICES Prosthetic Devices § 886.3200 Artificial eye. (a) Identification. An artificial eye is a device resembling the anterior portion of the eye, usually made of glass or plastic, intended to...

  7. 21 CFR 886.3200 - Artificial eye.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Artificial eye. 886.3200 Section 886.3200 Food and... OPHTHALMIC DEVICES Prosthetic Devices § 886.3200 Artificial eye. (a) Identification. An artificial eye is a device resembling the anterior portion of the eye, usually made of glass or plastic, intended to...

  8. 21 CFR 878.4440 - Eye pad.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Eye pad. 878.4440 Section 878.4440 Food and Drugs... GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4440 Eye pad. (a) Identification. An eye pad is... use as a bandage over the eye for protection or absorption of secretions. (b) Classification. Class...

  9. Eye Movement Disorders in Dyslexia. Final Report.

    ERIC Educational Resources Information Center

    Festinger, Leon; And Others

    Eye movements of 18 male and seven female dyslexic children and 10 normal children were evaluated to determine if eye movement disorders may be the cause of some of the symptoms associated with dyslexia. Data on eye movements were collected while Ss moved their eyes from one fixation point to another in a nonreading situation. Errors in vertical…

  10. Eye Movements, Perceptual Span, and Reading Disability.

    ERIC Educational Resources Information Center

    Rayner, Keith

    1983-01-01

    Research is reviewed on eye movements during reading, on the perceptual span and control of eye movements during normal reading, and on the nature of eye movements in dyslexia. Rather than the cause of dyslexia, eye movements are said to reflect underlying cognitive or neurological problems. (CL)

  11. Contact Lens-Related Eye Infections

    MedlinePlus

    ... Stories Español Eye Health / Eye Health A-Z Contact Lens-Related Eye Infections Sections Contact Lens-Related ... About Contact Lenses Proper Care of Contact Lenses Contact Lens-Related Eye Infections Written by: Kierstan Boyd ...

  12. A New Method to Assess Eye Dominance

    ERIC Educational Resources Information Center

    Valle-Inclan, Fernando; Blanco, Manuel J.; Soto, David; Leiros, Luz

    2008-01-01

    People usually show a stable preference for one of their eyes when monocular viewing is required ("sighting dominance") or under dichoptic stimulation conditions ("sensory eye-dominance"). Current procedures to assess this "eye dominance" are prone to error. Here we present a new method that provides a continuous measure of eye dominance and…

  13. Recent developments on dry eye disease treatment compounds

    PubMed Central

    Colligris, Basilio; Alkozi, Hanan Awad; Pintor, Jesus

    2013-01-01

    Dry eye syndrome is a common tears and ocular surface multifactorial disease, described by changes in the ocular surface epithelia related to reduced tears quantity and ocular surface sensitivity, leading to inflammatory reaction. Managing the eye inflammation proved helpful to patients with dry eye disease and current treatment is based on the use of topically applied artificial tear products/lubricants, tear retention management, stimulation of tear secretion and using anti-inflammatory drugs. In this article we revise the corresponding literature and patents assembling the new treatment approaches of novel and future pharmaceutical compounds destined for the dry eye disease treatment. The most frequent categories of compounds presented are secretagogues and anti-inflammatory drugs. These compounds are the research outcome of novel therapeutic strategies designed to reduce key inflammatory pathways and restore healthy tear film. PMID:24526854

  14. The perception of heading during eye movements

    NASA Technical Reports Server (NTRS)

    Royden, Constance S.; Banks, Martin S.; Crowell, James A.

    1992-01-01

    Warren and Hannon (1988, 1990), while studying the perception of heading during eye movements, concluded that people do not require extraretinal information to judge heading with eye/head movements present. Here, heading judgments are examined at higher, more typical eye movement velocities than the extremely slow tracking eye movements used by Warren and Hannon. It is found that people require extraretinal information about eye position to perceive heading accurately under many viewing conditions.

  15. Severity of Age-Related Macular Degeneration in 1 Eye and the Incidence and Progression of Age-Related Macular Degeneration in the Fellow Eye

    PubMed Central

    Gangnon, Ronald E.; Lee, Kristine E.; Klein, Barbara E. K.; Iyengar, Sudha K.; Sivakumaran, Theru A.; Klein, Ronald

    2014-01-01

    Importance Previous studies of the implications of age-related macular degeneration (AMD) severity in one eye on prognosis for the fellow eye have focused on incidence of neovascular AMD in the fellow eye of subjects with neovascular AMD in the other eye. It is unclear to what extent AMD severity in one eye impacts incidence, progression, and regression of AMD in its fellow eye across the entire range of AMD severity. Objective To investigate the impact of severity of AMD in one eye on incidence, progression, and regression of AMD in the fellow eye. Design, Setting and Participants The Beaver Dam Eye Study, a longitudinal population-based study of age-related eye diseases conducted in the city and township of Beaver Dam, Wisconsin. Examinations were performed every 5 years over a 20-year period (1988-1990 through 2008-2010). Study participants (N=4379) were aged 43 to 86 years at the baseline examination. At baseline and up to 4 subsequent examinations, retinal photographs were taken. Exposures Age, sex, and the Y402H polymorphism in the Complement Factor H gene on chromosome 1q; AMD severity in the fellow eye. Main Outcome Measures Incidence, progression, and regression of AMD assessed in retinal photographs according to the Wisconsin Age-Related Maculopathy Grading System; mortality. Results More severe AMD in one eye was associated with increased incidence and progression of AMD in its fellow eye (Level 1 to 2: hazard ratio [HR] 4.90, 95% confidence interval [CI] 4.26-5.63; Level 2 to 3: HR 2.09, CI 1.42-3.06; Level 3 to 4: HR 2.38, CI 1.74-3.25; Level 4 to Level 5: HR 2.46, CI 1.65-3.66). Less severe AMD in one eye was associated with less progression of AMD in its fellow eye (Level 2 to 3: HR 0.42, CI 0.33-0.55; Level 3 to 4: HR 0.50, CI 0.34-0.83). We estimate that 51% of subjects who develop any AMD always maintain AMD severity states within 1 step of each other between eyes; 90% stay within 2 steps. Conclusions and Relevance Using multi-state models, we

  16. Drugs affecting the eye.

    PubMed

    Taylor, F

    1985-08-01

    This discussion reviews drugs that affect the eye, including antihyperglycemic agents; corticosteroids; antirheumatic drugs (quinolines, indomethacin, and allopurinol); psychiatric drugs (phenothiazine, thioridazine, and chlorpromazine); drugs used in cardiology (practolol, amiodarone, and digitalis gylcosides); drugs implicated in optic neuritis and atrophy, drugs with an anticholinergic action; oral contraceptives (OCs); and topical drugs and systemic effects. Refractive changes, either myopic or hypermetropic, can occur as a result of hyperglycemia, and variation in vision is sometimes a presenting symptom in diabetes mellitus. If it causes a change in the refraction, treatment of hyperglycemia almost always produces a temporary hypermetropia. A return to the original refractive state often takes weeks, sometimes months. There is some evidence that patients adequately treated with insulin improve more rapidly than those taking oral medication. Such patients always should be referred for opthalmological evaluation as other factors might be responsible, but it might not be possible to order the appropriate spectacle correction for some time. The most important ocular side effect of the systemic adiministration of corticosteroids is the formation of a posterior subcapsular cataract. Glaucoma also can result from corticosteroids, most often when they are applied topically. Corticosteroids have been implicated in the production of benign intracranial hypertension, which is paradoxical because they also are used in its treatment. The most important side effect of drugs such as chloroquine and hydroxychloroquine is an almost always irreversible maculopathy with resultant loss of central vision. Corneal and retinal changes similar to those caused by the quinolines have been reported with indomethacin, but there is some question about a cause and effect relationship. The National Registry of Drug Induced Ocular Side Effects in the US published 30 case histories of

  17. Eye movements reset visual perception

    PubMed Central

    Paradiso, Michael A.; Meshi, Dar; Pisarcik, Jordan; Levine, Samuel

    2012-01-01

    Human vision uses saccadic eye movements to rapidly shift the sensitive foveal portion of our retina to objects of interest. For vision to function properly amidst these ballistic eye movements, a mechanism is needed to extract discrete percepts on each fixation from the continuous stream of neural activity that spans fixations. The speed of visual parsing is crucial because human behaviors ranging from reading to driving to sports rely on rapid visual analysis. We find that a brain signal associated with moving the eyes appears to play a role in resetting visual analysis on each fixation, a process that may aid in parsing the neural signal. We quantified the degree to which the perception of tilt is influenced by the tilt of a stimulus on a preceding fixation. Two key conditions were compared, one in which a saccade moved the eyes from one stimulus to the next and a second simulated saccade condition in which the stimuli moved in the same manner but the subjects did not move their eyes. We find that there is a brief period of time at the start of each fixation during which the tilt of the previous stimulus influences perception (in a direction opposite to the tilt aftereffect)—perception is not instantaneously reset when a fixation starts. Importantly, the results show that this perceptual bias is much greater, with nearly identical visual input, when saccades are simulated. This finding suggests that, in real-saccade conditions, some signal related to the eye movement may be involved in the reset phenomenon. While proprioceptive information from the extraocular muscles is conceivably a factor, the fast speed of the effect we observe suggests that a more likely mechanism is a corollary discharge signal associated with eye movement. PMID:23241264

  18. Eye movements reset visual perception.

    PubMed

    Paradiso, Michael A; Meshi, Dar; Pisarcik, Jordan; Levine, Samuel

    2012-01-01

    Human vision uses saccadic eye movements to rapidly shift the sensitive foveal portion of our retina to objects of interest. For vision to function properly amidst these ballistic eye movements, a mechanism is needed to extract discrete percepts on each fixation from the continuous stream of neural activity that spans fixations. The speed of visual parsing is crucial because human behaviors ranging from reading to driving to sports rely on rapid visual analysis. We find that a brain signal associated with moving the eyes appears to play a role in resetting visual analysis on each fixation, a process that may aid in parsing the neural signal. We quantified the degree to which the perception of tilt is influenced by the tilt of a stimulus on a preceding fixation. Two key conditions were compared, one in which a saccade moved the eyes from one stimulus to the next and a second simulated saccade condition in which the stimuli moved in the same manner but the subjects did not move their eyes. We find that there is a brief period of time at the start of each fixation during which the tilt of the previous stimulus influences perception (in a direction opposite to the tilt aftereffect)--perception is not instantaneously reset when a fixation starts. Importantly, the results show that this perceptual bias is much greater, with nearly identical visual input, when saccades are simulated. This finding suggests that, in real-saccade conditions, some signal related to the eye movement may be involved in the reset phenomenon. While proprioceptive information from the extraocular muscles is conceivably a factor, the fast speed of the effect we observe suggests that a more likely mechanism is a corollary discharge signal associated with eye movement. PMID:23241264

  19. Chance and Necessity in Eye Evolution

    PubMed Central

    Gehring, Walter J.

    2011-01-01

    Charles Darwin has proposed the theory that evolution of live organisms is based on random variation and natural selection. Jacques Monod in his classic book Chance and Necessity, published 40 years ago, presented his thesis “that the biosphere does not contain a predictable class of objects or events, but constitutes a particular occurrence, compatible indeed with the first principles, but not deducible from those principals and therefore, essentially unpredictable.” Recent discoveries in eye evolution are in agreement with both of these theses. They confirm Darwin's assumption of a simple eye prototype and lend strong support for the notion of a monophyletic origin of the various eye types. Considering the complexity of the underlying gene regulatory networks the unpredictability is obvious. The evolution of the Hox gene cluster and the specification of the body plan starting from an evolutionary prototype segment is discussed. In the course of evolution, a series of similar prototypic segments gradually undergoes cephalization anteriorly and caudalization posteriorly through diversification of the Hox genes. PMID:21979158

  20. [Georg Friedrich Händel's eye disease].

    PubMed

    Evers, S

    1993-09-01

    In his last years Georg Friedrich Händel suffered from a loss of sight not definitely to be defined. Based on primary sources, this disease, often mentioned in his biographies, is described and analysed. Altogether, Händel's eye-disease can be best interpreted as a central vascular disorder with degeneration of retina or with ischemic changes in the corresponding nuclei or tractus, complicated by a simple senile or post-traumatic cataract. Händel's profile of risk factors points most probably to a vascular degeneration of macula or a damage of choroidal vessels. Händel's eye-disease must be seen in relation to his cerebro-vascular disorder. His most probable strokes as well as his loss of sight were of vital importance in his biography, as is reflected even by his compositions. However, both disorders did not fundamentally influence his creativity. Only in a few compositions a reference to the loss of sight can be found. Apart from changes in concert-practising during his last years Händel's eye-disease, however, had no direct effect on his musical work. PMID:8264215

  1. Stem cell treatment of degenerative eye disease☆

    PubMed Central

    Mead, Ben; Berry, Martin; Logan, Ann; Scott, Robert A.H.; Leadbeater, Wendy; Scheven, Ben A.

    2015-01-01

    Stem cell therapies are being explored extensively as treatments for degenerative eye disease, either for replacing lost neurons, restoring neural circuits or, based on more recent evidence, as paracrine-mediated therapies in which stem cell-derived trophic factors protect compromised endogenous retinal neurons from death and induce the growth of new connections. Retinal progenitor phenotypes induced from embryonic stem cells/induced pluripotent stem cells (ESCs/iPSCs) and endogenous retinal stem cells may replace lost photoreceptors and retinal pigment epithelial (RPE) cells and restore vision in the diseased eye, whereas treatment of injured retinal ganglion cells (RGCs) has so far been reliant on mesenchymal stem cells (MSC). Here, we review the properties of non-retinal-derived adult stem cells, in particular neural stem cells (NSCs), MSC derived from bone marrow (BMSC), adipose tissues (ADSC) and dental pulp (DPSC), together with ESC/iPSC and discuss and compare their potential advantages as therapies designed to provide trophic support, repair and replacement of retinal neurons, RPE and glia in degenerative retinal diseases. We conclude that ESCs/iPSCs have the potential to replace lost retinal cells, whereas MSC may be a useful source of paracrine factors that protect RGC and stimulate regeneration of their axons in the optic nerve in degenerate eye disease. NSC may have potential as both a source of replacement cells and also as mediators of paracrine treatment. PMID:25752437

  2. A novel nanoscale-dispersed eye ointment for the treatment of dry eye disease.

    PubMed

    Zhang, Wenjian; Wang, Yan; Lee, Benjamin Tak Kwong; Liu, Chang; Wei, Gang; Lu, Weiyue

    2014-03-28

    A novel nanoscale-dispersed eye ointment (NDEO) for the treatment of severe evaporative dry eye has been successfully developed. The excipients used as semisolid lipids were petrolatum and lanolin, as used in conventional eye ointment, which were coupled with medium-chain triglycerides (MCT) as a liquid lipid; both phases were then dispersed in polyvinyl pyrrolidone solution to form a nanodispersion. Single-factor experiments were conducted to optimize the formulations. A transmission electron micrograph showed that the ointment matrix was entrapped in the nanoemulsion of MCT, with a mean particle size of about 100 nm. The optimized formulation of NDEO was stable when stored for six months at 4 °C, and demonstrated no cytotoxicity to human corneal epithelial cells when compared with commercial polymer-based artificial tears (Tears Natural Forte). The therapeutic effects of NDEO were evaluated on a mouse model with 'dry eye'. Both the tear break-up time and fluorescein staining demonstrated therapeutic improvement, displaying a trend of positive correlation with higher concentrations of ointment matrix in the NDEO formulations compared to a marketed product. Histological evaluation demonstrated that the NDEO restored the normal corneal and conjunctival morphology and is safe for ophthalmic application. PMID:24571862

  3. Can children with autism read emotions from the eyes? The eyes test revisited.

    PubMed

    Franco, Fabia; Itakura, Shoji; Pomorska, Krystyna; Abramowski, Anna; Nikaido, Kozue; Dimitriou, Dagmara

    2014-05-01

    This study aimed to test two new, simplified tasks related to the eye-test, targeting children with autism spectrum disorder (ASD) and typically developing controls (TD). Test-1 assessed the recognition of emotion/mental states with displays using one word and two eye-pictures, whereas Test-2 presented displays using two words and one eye-picture. Black and white photographs of children were used as materials. A cross-cultural study (Caucasian/East-Asian) with adults was initially carried out to verify generalizability across different ethnic groups. Cross-sectional trajectory analyses were used to compare emotion recognition from the eyes in the two tests. Trajectories were constructed linking performance on both tests either to chronological age or to different measures of mental age (receptive vocabulary based on the BPVS, CARS or ASQ for the ASD group). Performance improved with chronological age in both the ASD and TD groups of children. However, performance in Test-1 was significantly superior in children with ASD, who showed delayed onset and slower rate of improvement than TD children in Test-2. In both the ASD and TD groups the lowest error rate was recorded for the item 'anger', suggesting that threat-detection cue mechanisms may be intact in autism. In general, all children showed good performance on our novel tests, thus making them good candidates for assessing younger children and those with lower general abilities. PMID:24636022

  4. Human eye anisoplanatism: eye as a lamellar structure

    NASA Astrophysics Data System (ADS)

    Dubinin, Alexander; Cherezova, Tatyana; Belyakov, Alexey; Kudryashov, Alexis

    2006-02-01

    In this paper we consider anisoplanatism effect as a fundamental limitation on the size of high resolution area (isoplanatic patch) of retinal images obtained using fundus cameras equipped with adaptive optics. Isoplanatic patch size was estimated using experimental results for on-axis and off-axis eye aberrations measured by Shack-Hartmann technique. Isoplanatic patch size varied among examined subjects in the range from 1.5 ° to 2.5 ° which is in good agreement with results obtained using ray-tracing technique1. We estimated isoplanatic patch size for Gullstrand eye model and found it to be close to the values obtained from experimental results for subjects with good vision. We also discuss the possibilities of Gullstrand eye model modifications for modeling anisoplanatism effect for each particular subject. We also estimated the efficiency of multibeacon correction method and found out that this method allows us to almost twice increase the area with high resolution.

  5. Dorsal eye selector pannier (pnr) suppresses the eye fate to define dorsal margin of the Drosophila eye

    PubMed Central

    Oros, Sarah M.; Tare, Meghana; Kango-Singh, Madhuri; Singh, Amit

    2010-01-01

    Axial patterning is crucial for organogenesis. During Drosophila eye development, dorso-ventral (DV) axis determination is the first lineage restriction event. The eye primordium begins with a default ventral fate, on which the dorsal eye fate is established by expression of the GATA-1 transcription factor pannier (pnr). Earlier, it was suggested that loss of pnr function induces enlargement in the dorsal eye due to ectopic equator formation. Interestingly, we found that in addition to regulating DV patterning, pnr suppresses the eye fate by downregulating the core retinal determination genes eyes absent (eya), sine oculis (so) and dacshund (dac) to define the dorsal eye margin. We found that pnr acts downstream of Ey and affect the retinal determination pathway by suppressing eya. Further analysis of the “eye suppression” function of pnr revealed that this function is likely mediated through suppression of the homeotic gene teashirt (tsh) and is independent of homothorax (hth), a negative regulator of eye. Pnr expression is restricted to the peripodial membrane on the dorsal eye margin, which gives rise to head structures around the eye, and pnr is not expressed in the eye disc proper that forms the retina. Thus, pnr has dual function, during early developmental stages pnr is involved in axial patterning whereas later it promotes the head specific fate. These studies will help in understanding the developmental regulation of boundary formation of the eye field on the dorsal eye margin. PMID:20691679

  6. How flies clean their eyes

    NASA Astrophysics Data System (ADS)

    Amador, Guillermo; Durand, Fabien; Mao, Wenbin; Alexeev, Alexander; Hu, David

    2013-11-01

    Flying insects face a barrage of foreign particles such as dust and pollen, which threaten to coat the insect's eyes and antennae, limiting their sensing abilities. In this study, we elucidate novel aerodynamic and elastic mechanisms by which insects keep these organs clean. The compound eye of many species of insects is covered by an array of short bristles, or setae, evenly spaced between each photoreceptor unit. Among these insect species, setae length is triple their spacing. We conduct numerical simulations and wind tunnel experiments using an insect eye mimic to show this critical setae length reduces shear rate at the eye surface by 80%. Thus, the setae create a stagnant zone in front of the eye, which diverts airflow to reduce deposition of particles. Setae can also act as springboards to catapult accumulated particles. In high speed videography of insects using their legs to clean themselves, we observe deflected setae hurling micron scale particles at accelerations over 100 times earth's gravity. The dual abilities of setae to divert airflow and catapult particles may motivate bio-inspired designs for dust-controlling lenses, sensors, and solar panels.

  7. Indications for eye removal surgeries

    PubMed Central

    Koylu, Mehmet T.; Gokce, Gokcen; Uysal, Yusuf; Ceylan, Osman M.; Akıncıoglu, Dorukcan; Gunal, Armagan

    2015-01-01

    Objectives: To analyze the indications and types of eye removals at a military tertiary care hospital in Turkey. Methods: The medical records (age, gender, affected eye, type of surgical procedure, indications of surgery) of 123 patients who underwent evisceration and enucleation in the course of a 15-year period (January 2000 to December 2014) at Gulhane Military Medical Academy, Ankara, Turkey were reviewed retrospectively. Results: The mean age was 35.61±18.52 (range 3-80 years). The number of male in the patient group was 92 (74.8%) and female was 31 (25.2%). Patients who underwent evisceration were 95 (77.2%), whereas 28 (22.8%) of them underwent enucleation. The mean age of the eviscerated patients was 30.63±13.08, whereas the mean age of the enucleated patients was 52.50±23.92 (p<0.001). The leading indications for eye amputations were trauma (n=62, 50.4%), malignancy (n=20, 16.3%), painful blind eye and absolute glaucoma (n=20, 16.3%), endophthalmitis (n=12, 9.7%), and phthisis bulbi, and cosmetic reasons (n=9, 7.3%). Conclusion: Trauma was the most common etiology for evisceration, and malignancy was the most common etiology for enucleation. Using protective eyewear and early detection of intraocular malignancy and glaucoma through routine ophthalmic examinations are essential for providing non-invasive treatment modalities instead of eye removal. PMID:26446332

  8. Eye-Eye with Dr. Rachel Bishop | NIH MedlinePlus the Magazine

    MedlinePlus

    ... this page please turn JavaScript on. Feature: Glaucoma Eye-to-Eye with Dr. Rachel Bishop Past Issues / Spring 2015 ... new patient comes in because they scratched their eye while working in the yard, or they think ...

  9. Videos from the National Eye Institute: Eye Diseases | NIH MedlinePlus the Magazine

    MedlinePlus

    ... this page please turn Javascript on. Feature: Vision Videos from the National Eye Institute: Eye Diseases Past ... the early detection of eye disease. Share these videos with friends, family and colleagues. www.nei.nih. ...

  10. Comparison of Dry Eye Parameters between Diabetics and Non-Diabetics in District of Kuantan, Pahang

    PubMed Central

    Aljarousha, Mohammed; Badarudin, Noor Ezailina; Che Azemin, Mohd Zulfaezal

    2016-01-01

    Introduction Diabetes may affect the human body’s systems and organs, including the eye. Diabetic retinopathy is the 5th leading cause of blindness globally. Diabetic subjects demonstrated dry eye symptoms that were also supported by the low values of the clinical tests. Purpose This study aimed to compare the dry eye symptoms and signs between diabetics and non-diabetics and tear functions between diabetic subjects with and without dry eye. Methods This retrospective study was based on the observation of 643 medical files. Using a convenience sampling method, 88 subjects were found to report diabetes mellitus. The information extracted from the files included: date of first examination, age at first visit, gender, past ocular history, systemic disease, symptoms of dry eye disease and details of clinical diagnostic signs. Non-contact lens wearers were excluded. A group of 88, age and gender matched, control subjects were included for this comparison study. Results The percentage of dry eye symptoms was higher in diabetic subjects (15.9%) compared with non-diabetic subjects (13.6%; p<0.001). The percentage of dry eye symptoms was also higher in diabetics with dry eye (63%) than in diabetics without dry eye (36.9%; p<0.001). Tear break up time was significantly different between diabetics and non-diabetics (p<0.001) and between diabetics with and without dry eye (p=0.046). The corneal staining was significantly different between diabetic subjects with and without dry eye (p=0.028). Conclusion Dry eye symptoms were significantly associated with diabetics. Tear break up time was significantly shorter in diabetics with dry eye compared to diabetics without dry eye. PMID:27418872

  11. Determinants of Utilization of Eye Care Services in a Rural Adult Population of a Developing Country

    PubMed Central

    Olusanya, Bolutife A.; Ashaye, Adeyinka O.; Owoaje, Eme T.; Baiyeroju, Aderonke M.; Ajayi, Benedictus G.

    2016-01-01

    Purpose: To describe the factors that determine the utilization of eye care services in a rural community in South-Western Nigeria. Methods: A descriptive cross-sectional survey using a multistage sampling technique was conducted. The main outcome measure was self-reported previous consultation of an orthodox medical facility for eye care. Results: The study sample included 643 participants. Only 122 (19%) respondents had previously visited orthodox facilities in search of eye care and 24% of those with presenting visual acuity <6/18 had sought eye care. Characteristics associated with previous utilization of eye care services were age of =70 years (odds ratio [OR] ≥ 1.7, P = 0.02); male gender (OR = 1.5, P = 0.04); literacy (OR = 1.7, P = 0.007); and residing close to an eye care facility (OR = 2.8, P < 0.001). Blind respondents were three times more likely to seek eye care (P < 0.001). Regression analysis revealed that factors associated with increased likelihood of utilization of eye care services included age ≥70 years; literacy; residence close to an eye facility; being diabetic or hypertensive; history of ocular symptoms, and blindness. Conclusions: These findings suggest that a significant proportion (75%) of adults in the study area are not utilizing eye care services and that blindness is an important determinant of utilization of eye care services. Health education and awareness campaigns about the importance and benefits of seeking eye care early, and the provision of community-based eye care programs are essential to boost the uptake of eye care services in this community as well as other rural areas of West Africa. PMID:26957847

  12. The Use of Eye Tracking in Research on Video-Based Second Language (L2) Listening Assessment: A Comparison of Context Videos and Content Videos

    ERIC Educational Resources Information Center

    Suvorov, Ruslan

    2015-01-01

    Investigating how visuals affect test takers' performance on video-based L2 listening tests has been the focus of many recent studies. While most existing research has been based on test scores and self-reported verbal data, few studies have examined test takers' viewing behavior (Ockey, 2007; Wagner, 2007, 2010a). To address this gap, in the…

  13. Tracking with the mind's eye

    NASA Technical Reports Server (NTRS)

    Krauzlis, R. J.; Stone, L. S.

    1999-01-01

    The two components of voluntary tracking eye-movements in primates, pursuit and saccades, are generally viewed as relatively independent oculomotor subsystems that move the eyes in different ways using independent visual information. Although saccades have long been known to be guided by visual processes related to perception and cognition, only recently have psychophysical and physiological studies provided compelling evidence that pursuit is also guided by such higher-order visual processes, rather than by the raw retinal stimulus. Pursuit and saccades also do not appear to be entirely independent anatomical systems, but involve overlapping neural mechanisms that might be important for coordinating these two types of eye movement during the tracking of a selected visual object. Given that the recovery of objects from real-world images is inherently ambiguous, guiding both pursuit and saccades with perception could represent an explicit strategy for ensuring that these two motor actions are driven by a single visual interpretation.

  14. Yarbus, eye movements, and vision

    PubMed Central

    Tatler, Benjamin W; Wade, Nicholas J; Kwan, Hoi; Findlay, John M; Velichkovsky, Boris M

    2010-01-01

    The impact of Yarbus's research on eye movements was enormous following the translation of his book Eye Movements and Vision into English in 1967. In stark contrast, the published material in English concerning his life is scant. We provide a brief biography of Yarbus and assess his impact on contemporary approaches to research on eye movements. While early interest in his work focused on his study of stabilised retinal images, more recently this has been replaced with interest in his work on the cognitive influences on scanning patterns. We extended his experiment on the effect of instructions on viewing a picture using a portrait of Yarbus rather than a painting. The results obtained broadly supported those found by Yarbus. PMID:23396904

  15. Making eye contact without awareness.

    PubMed

    Rothkirch, Marcus; Madipakkam, Apoorva Rajiv; Rehn, Erik; Sterzer, Philipp

    2015-10-01

    Direct gaze is a potent non-verbal signal that establishes a communicative connection between two individuals, setting the course for further interactions. Although consciously perceived faces with direct gaze have been shown to capture attention, it is unknown whether an attentional preference for these socially meaningful stimuli exists even in the absence of awareness. In two experiments, we recorded participants' eye movements while they were exposed to faces with direct and averted gaze rendered invisible by interocular suppression. Participants' inability to correctly guess the occurrence of the faces in a manual forced-choice task demonstrated complete unawareness of the faces. However, eye movements were preferentially directed towards faces with direct compared to averted gaze, indicating a specific sensitivity to others' gaze directions even without awareness. This oculomotor preference suggests that a rapid and automatic establishment of mutual eye contact constitutes a biological advantage, which could be mediated by fast subcortical pathways in the human brain. PMID:26133642

  16. Aspectual coercion in eye movements.

    PubMed

    Townsend, David J

    2013-06-01

    Comprehension includes interpreting sentences in terms of aspectual categories such as processes (Harry climbed) and culminations (Harry reached the top). Adding a verbal modifier such as for many years to a culmination coerces its interpretation from one to many culminations. Previous studies have found that coercion increases lexical decision and meaning judgment time, but not eye fixation time. This study recorded eye movements as participants read sentences in which a coercive adverb increased the interpretation of multiple events. Adverbs appeared at the end of a clause and line; the post-adverb region appeared at the beginning of the next line; follow-up questions occasionally asked about aspectual meaning; and clause type varied systematically. Coercive adverbs increased eye fixation time in the post-adverb region and in the adverb and post-adverb regions combined. Factors that influence the appearance of aspectual coercion may include world knowledge, follow-up questions, and the location and ambiguity of adverbs. PMID:22492206

  17. Moving Ahead With Eye Power

    NASA Technical Reports Server (NTRS)

    2002-01-01

    NASA's Jet Propulsion Laboratory's collaborated with LC Technologies, Inc., to improve LCT's Eyegaze Communication System, an eye tracker that enables people with severe cerebral palsy, muscular dystrophy, multiple sclerosis, strokes, brain injuries, spinal cord injuries, and ALS (amyotrophic lateral sclerosis) to communicate and control their environment using their eye movements. To operate the system, the user sits in front of the computer monitor while the camera focuses on one eye. By looking at control keys on the monitor for a fraction of a second, the user can 'talk' with speech synthesis, type, operate a telephone, access the Internet and e-mail, and run computer software. Nothing is attached to the user's head or body, and the improved size and portability allow the system to be mounted on a wheelchair. LCT and JPL are working on several other areas of improvement that have commercial add-on potential.

  18. PACAP suppresses dry eye signs by stimulating tear secretion.

    PubMed

    Nakamachi, Tomoya; Ohtaki, Hirokazu; Seki, Tamotsu; Yofu, Sachiko; Kagami, Nobuyuki; Hashimoto, Hitoshi; Shintani, Norihito; Baba, Akemichi; Mark, Laszlo; Lanekoff, Ingela; Kiss, Peter; Farkas, Jozsef; Reglodi, Dora; Shioda, Seiji

    2016-01-01

    Dry eye syndrome is caused by a reduction in the volume or quality of tears. Here, we show that pituitary adenylate cyclase-activating polypeptide (PACAP)-null mice develop dry eye-like symptoms such as corneal keratinization and tear reduction. PACAP immunoreactivity is co-localized with a neuronal marker, and PACAP receptor (PAC1-R) immunoreactivity is observed in mouse infraorbital lacrimal gland acinar cells. PACAP eye drops stimulate tear secretion and increase cAMP and phosphorylated (p)-protein kinase A levels in the infraorbital lacrimal glands that could be inhibited by pre-treatment with a PAC1-R antagonist or an adenylate cyclase inhibitor. Moreover, these eye drops suppress corneal keratinization in PACAP-null mice. PACAP eye drops increase aquaporin 5 (AQP5) levels in the membrane and pAQP5 levels in the infraorbital lacrimal glands. AQP5 siRNA treatment of the infraorbital lacrimal gland attenuates PACAP-induced tear secretion. Based on these results, PACAP might be clinically useful to treat dry eye disorder. PMID:27345595

  19. Predicting the Valence of a Scene from Observers’ Eye Movements

    PubMed Central

    R.-Tavakoli, Hamed; Atyabi, Adham; Rantanen, Antti; Laukka, Seppo J.; Nefti-Meziani, Samia; Heikkilä, Janne

    2015-01-01

    Multimedia analysis benefits from understanding the emotional content of a scene in a variety of tasks such as video genre classification and content-based image retrieval. Recently, there has been an increasing interest in applying human bio-signals, particularly eye movements, to recognize the emotional gist of a scene such as its valence. In order to determine the emotional category of images using eye movements, the existing methods often learn a classifier using several features that are extracted from eye movements. Although it has been shown that eye movement is potentially useful for recognition of scene valence, the contribution of each feature is not well-studied. To address the issue, we study the contribution of features extracted from eye movements in the classification of images into pleasant, neutral, and unpleasant categories. We assess ten features and their fusion. The features are histogram of saccade orientation, histogram of saccade slope, histogram of saccade length, histogram of saccade duration, histogram of saccade velocity, histogram of fixation duration, fixation histogram, top-ten salient coordinates, and saliency map. We utilize machine learning approach to analyze the performance of features by learning a support vector machine and exploiting various feature fusion schemes. The experiments reveal that ‘saliency map’, ‘fixation histogram’, ‘histogram of fixation duration’, and ‘histogram of saccade slope’ are the most contributing features. The selected features signify the influence of fixation information and angular behavior of eye movements in the recognition of the valence of images. PMID:26407322

  20. PACAP suppresses dry eye signs by stimulating tear secretion

    PubMed Central

    Nakamachi, Tomoya; Ohtaki, Hirokazu; Seki, Tamotsu; Yofu, Sachiko; Kagami, Nobuyuki; Hashimoto, Hitoshi; Shintani, Norihito; Baba, Akemichi; Mark, Laszlo; Lanekoff, Ingela; Kiss, Peter; Farkas, Jozsef; Reglodi, Dora; Shioda, Seiji

    2016-01-01

    Dry eye syndrome is caused by a reduction in the volume or quality of tears. Here, we show that pituitary adenylate cyclase-activating polypeptide (PACAP)-null mice develop dry eye-like symptoms such as corneal keratinization and tear reduction. PACAP immunoreactivity is co-localized with a neuronal marker, and PACAP receptor (PAC1-R) immunoreactivity is observed in mouse infraorbital lacrimal gland acinar cells. PACAP eye drops stimulate tear secretion and increase cAMP and phosphorylated (p)-protein kinase A levels in the infraorbital lacrimal glands that could be inhibited by pre-treatment with a PAC1-R antagonist or an adenylate cyclase inhibitor. Moreover, these eye drops suppress corneal keratinization in PACAP-null mice. PACAP eye drops increase aquaporin 5 (AQP5) levels in the membrane and pAQP5 levels in the infraorbital lacrimal glands. AQP5 siRNA treatment of the infraorbital lacrimal gland attenuates PACAP-induced tear secretion. Based on these results, PACAP might be clinically useful to treat dry eye disorder. PMID:27345595