Sample records for femur shaft fracture

  1. A new classification and treatment protocol for combined fractures of the femoral shaft with the proximal or distal femur with closed locked intramedullary nailing: clinical experience of 63 fractures.

    PubMed

    Lambiris, Elias; Giannikas, Dimitrios; Galanopoulos, George; Tyllianakis, Minos; Megas, Panagiotis

    2003-03-01

    The medical records and radiographs of 63 patients, who were admitted between 1989-1997, with a combined femur fracture, were reviewed. Associated injuries were present in 38 (60%) patients. The combined fractures were classified into four major types depending on their anatomical position: type I, femoral shaft fracture combined with hip neck fracture; type II, femoral shaft fracture combined with a trochanteric fracture; type III, femoral shaft fracture combined with a distal femur fracture; and type IV, femoral shaft fracture combined with a proximal or distal femur fracture. The fractures were treated with locked intramedullary nailing and additional free cancellous 6.5-mm screws as needed. Fifty-six fractures healed without further operations. Of the remaining 6 fractures, 2 were material failures, 1 malunion with 3-cm shortening and external rotation of the femoral diaphysis, 2 early infections of the surgical wound, and 1 pseudarthrosis of the femoral shaft. All fractures were healed between 16 and 32 weeks (average: 20 weeks).

  2. Lateral and posterior dynamic bending of the mid-shaft femur: fracture risk curves for the adult population.

    PubMed

    Kennedy, Eric A; Hurst, William J; Stitzel, Joel D; Cormier, Joseph M; Hansen, Gail A; Smith, Eric P; Duma, Stefan M

    2004-11-01

    The purpose of this study was to develop injury risk functions for dynamic bending of the human femur in the lateral-to-medial and posterior-to-anterior loading directions. A total of 45 experiments were performed on human cadaver femurs using a dynamic three-point drop test setup. An impactor of 9.8 kg was dropped from 2.2 m for an impact velocity of 5 m/s. Five-axis load cells measured the impactor and support loads, while an in situ strain gage measured the failure strain and subsequent strain rate. All 45 tests resulted in mid-shaft femur fractures with comminuted wedge and oblique fractures as the most common fracture patterns. In the lateral-to-medial bending tests the reaction loads were 4180 +/- 764 N, and the impactor loads were 4780 +/- 792 N. In the posterior-to-anterior bending tests the reaction loads were 3780 +/- 930 N, and the impactor loads were 4310 +/- 1040 N. The difference between the sum of the reaction forces and the applied load is due to inertial effects. The reaction loads were used to estimate the mid-shaft bending moments at failure since there was insufficient data to include the inertial effects in the calculations. The resulting moments are conservative estimates (lower bounds) of the mid-shaft bending moments at failure and are appropriate for use in the assessment of knee restraints and pedestrian impacts with ATD measurements. Regression analysis was used to identify significant parameters, and parametric survival analysis was used to estimate risk functions. Femur cross-sectional area, area moment of inertia (I), maximum distance to the neutral axis (c), I/c, occupant gender, and occupant mass are shown to be significant predictors of fracture tolerance, while no significant difference is shown for loading direction, bone mineral density, leg aspect and age. Risk functions are presented for femur cross-sectional area and I/c as they offer the highest correlation to peak bending moment. The risk function that utilizes the most

  3. Fecal Fistula Communicating with a Femur Shaft Fracture Secondary to a Malpositioned Suprapubic Catheter: A Case Report

    PubMed Central

    Guled, Uday; Goni, Vijay G.; Honnurappa, Arjun R.H.; John, Rakesh; Vardhana, Harsha; Sharma, Gaurav; Pattabhiraman, Kirubakaran S.

    2015-01-01

    Patient: Male, 18 Final Diagnosis: Fecal fistula communicating with fracture shaft femur secondary to malpositioned SPC Symptoms: — Medication: — Clinical Procedure: Advertisement and rail fixator application Specialty: Orthopedics and Trauamtology Objective: Diagnostic/therapeutic accidents Background: Suprapubic catheter (SPC) insertion is a common urological procedure. Though considered a simple and safe procedure, complications are bound to occur if proper precautions are not taken during the procedure. The reported complications include gross hematuria, post-obstruction diuresis, insertion site skin-related complications, and intra-abdominal visceral injuries. Iatrogenic bowel injuries have been reported to occur as a complication in around 2.5% of cases. Case Report: We report a very rare case of a bowel injury due to improper insertion of a SPC leading to fecal matter tracking along the muscle planes to reach the fracture site of the femur shaft and formation of an external fecal fistula along the lateral aspect of thigh, which according to us is the first reported case in the literature. Conclusions: This case report shows the devastating complication of a technically simple procedure done in an improper manner and successful management of a rare case of femur fracture with communicating fecal fistula. The purpose of this case report is to highlight the importance of taking proper precautions before the procedure. PMID:26439133

  4. Ipsilateral obturator type of hip dislocation with fracture shaft femur in a child: a case report and literature review.

    PubMed

    Arjun, R H H; Kumar, Vishal; Saibaba, Balaji; John, Rakesh; Guled, Uday; Aggarwal, Sameer

    2016-09-01

    The incidence of traumatic hip dislocations in children is rising in this fast developing world along with increasing numbers of high-velocity road traffic accidents. Anterior dislocation of the hip has a lower incidence compared with posterior dislocation of the hip. We encountered a rare case of the obturator type of anteriorly dislocated hip associated with ipsilateral fracture of the shaft femur in an 11-year-old child. This is a highly unusual injury combination and the mechanism of injury is obscure. Only two similar cases have been reported in the English literature to date. Closed reduction of the hip using a hitherto undescribed technique and an intramedullary interlocking nail was performed in this case. At 6 months of follow-up, the fracture shaft femur has united and the child is bearing full weight on the limb.

  5. Percutaneous K-Wire Fixation for Femur Shaft Fractures in Children: A Treatment Concepts for Developing Countries

    PubMed Central

    Sahu, RL

    2013-01-01

    Background: Fractures shaft femur is a major cause of morbidity and mortality in patients with lower extremity injuries. Aims: The aim of this study was to evaluate the efficacy of intramedullary Kirschner wires for the treatment of femoral shaft fracture in children. Subjects and Methods: This prospective study was conducted in the Department of Orthopaedic surgery in M. M. Medical College from June 2005 to June 2010. Sixty eight children with a mean age of 7.7 years (range, 2-14 years) were recruited from Emergency and out patient department having closed fracture of femoral shaft. All patients were operated under general anesthesia. All patients were followed for twelve months. Results: Out of sixty eight patients, sixty four patients underwent union in 42 to 70 days with a mean of 56 days. Touch down weight bearing was started on 2nd post-operative day. Complications found in four patients who had insignificant delayed union which were united next three weeks. Intramedullary Kirschner-wires were removed after an average of five months without any complications. The results were excellent in 94.1% (64/68) and good in 5.8% (4/68). Conclusion: This technique is simple, quick to perform, safe and reliable and avoids prolonged hospitalization with good results and is economical. PMID:23919189

  6. Bilateral simultaneous femoral neck and shafts fractures - a case report.

    PubMed

    Sadeghifar, Amirreza; Saied, Alireza

    2014-10-01

    Simultaneous fractures of the femoral neck and shaft are not common injuries, though they cannot be considered rare. Herein, we report our experience with a patient with bilateral occurance of this injury. Up to the best of our knowkedge this is the first case reported in literature in which correct diagnosis was made initially. Both femurs were fixed using broad 4.5 mm dynamic compression plate and both necks were fixed using 6.5 mm cannulated screws. Femur fixation on one side was converted to retrograde nailing because of plate failure. Both neck fractures healed uneventfully. In spite of rarity of concomitant fractures of femoral neck and shaft, this injury must be approached carefully demanding especial attention and careful device selection.

  7. Titanium elastic nail - Complications in the treatment of paediatric diaphyseal fracture of femur [corrected].

    PubMed

    Sarkar, Saikat; Bandyopadhyay, Ranadeb; Mukherjee, Arindam

    2013-01-01

    Femoral shaft fracture is the most common major paediatric orthopaedic. For generations traction and casting was the standard treatment for all femoral shaft fractures in children. Over the past two decades the advantages of fixation and rapid mobilisation have been increasingly recognised. A prospective study was conducted in five private hospitals in the district of Bankura, West Bengal over a period of two years (April 2010 to March 2012) on 70 patients with closed shaft femur fractures between 6- 14 years age of either sex. The aim was to find out the short term complications of titanium elastic nailing in diaphyseal fracture of femur in children and compare the findings of this study with pre- existing studies in this field. In our study the most common complication was pain at nail entry site (60%). 5.71% had local inflammatory reaction due to nails. Superficial infection occurred in 2.85%. At the end of 1 year, 2.85% had limb length discripancies. Proximal migration occurred in 2.85%. 2.85% encountered acute reactive synovitis, 5.71% developed angulation of fracture site and 2.85% developed per operative breakage of nail. The treatment of paediatric shaft femur fracture has been drastically changed over the last two decades to internal fixation by elastically stable intra- medullary nail (ESIN). In our study, we encountered only a few complications most of them being minor. Most of the complications were surgical technique related and were seen at the initial phase of the learning curve.

  8. Intramedullary Stabilization of Periprosthetic Fractures of the Femur Taking Special Account of Bone Defects.

    PubMed

    Eingartner, Christoph; Volkmann, Rüdiger; Ochs, Uwe; Egetemeyr, Daniel; Weise, Kuno

    2007-10-01

    Healing of the periprosthetic fracture and area of defective bone by the bone healing mechanisms of intramedullary stabilization. Reconstruction of the correct length, axial alignment, and rotation of the fractured femoral shaft by anchoring a revision stem in the intact femoral diaphysis. Periprosthetic femoral shaft fracture in the region of the prosthetic stem combined with preexistent loosening and/or defect in the periprosthetic bone bed (Vancouver classification type B2 and B3). General contraindications, local infection. Lateral transmuscular approach to the femoral shaft. Longitudinal osteotomy of the proximal femur taking the geometry of the fracture into account. Opening of an anterior "bone shell". Removal of the loose prosthetic stem and cement. Debridement. Preparation of the femoral diaphysis and insertion of a distally anchored revision stem. Distal locking. Repositioning of the "bone shell", reduction of the fracture, and retention with cerclage wires. Bed rest for approximately 1 week, mobilization with 20 kg partial weight bearing for 12 weeks, gradual increase in weight bearing with radiologic checks on progress, removal of the distal locking bolts after 12-24 months at the earliest. 21 patients (13 women, eight men) aged between 43 and 86 years (mean age: 71.2 years) with periprosthetic fracture of the femur, additional loosening of the stem in eight cases (Vancouver B2) and additional bone loss in 13 cases (Vancouver B3). Postoperative complications: two fractures following another fall (repeat operations: one replacement, one plate), four revisions due to subsidence of the stem (three replacements involving change to a standard stem with healed proximal femur, one replacement with another interlocked revision stem). Bone healing occurred for all fractures after a mean 5.6 months (3-11 months). Follow- up examination after a mean 4.5 years: all patients were able to walk, average Harris Score 70.5 points (29- 95 points).

  9. Intramedullary stabilization of periprosthetic fractures of the femur taking special account of bone defects.

    PubMed

    Eingartner, Christoph; Volkmann, Rüdiger; Ochs, Uwe; Egetemeyr, Daniel; Weise, Kuno

    2006-10-01

    Healing of the periprosthetic fracture and area of defective bone by the bone healing mechanisms of intramedullary stabilization. Reconstruction of the correct length, axial alignment, and rotation of the fractured femoral shaft by anchoring a revision stem in the intact femoral diaphysis. Periprosthetic femoral shaft fracture in the region of the prosthetic stem combined with preexistent loosening and/or defect in the periprosthetic bone bed (Vancouver classification type B2 and B3). General contraindications, local infection. Lateral transmuscular approach to the femoral shaft. Longitudinal osteotomy of the proximal femur taking the geometry of the fracture into account. Opening of an anterior "bone shell". Removal of the loose prosthetic stem and cement. Debridement. Preparation of the femoral diaphysis and insertion of a distally anchored revision stem. Distal locking. Repositioning of the "bone shell", reduction of the fracture, and retention with cerclage wires. Bed rest for approximately 1 week, mobilization with 20 kg partial weight bearing for 12 weeks, gradual increase in weight bearing with radiologic checks on progress, removal of the distal locking bolts after 12-24 months at the earliest. 21 patients (13 women, eight men) aged between 43 and 86 years (mean age: 71.2 years) with periprosthetic fracture of the femur, additional loosening of the stem in eight cases (Vancouver B2) and additional bone loss in 13 cases (Vancouver B3). Postoperative complications: two fractures following another fall (repeat operations: one replacement, one plate), four revisions due to subsidence of the stem (three replacements involving change to a standard stem with healed proximal femur, one replacement with another interlocked revision stem). Bone healing occurred for all fractures after a mean 5.6 months (3-11 months). Follow-up examination after a mean 4.5 years: all patients were able to walk, average Harris Score 70.5 points (29-95 points).

  10. Osteosynthesis of fractures of the femur with flexible metallic intramedullary nails.

    PubMed

    Firica, A; Troianescu, O; Petre, M

    1978-04-01

    The authors discuss their use of Ender's method in the treatment of fractures of the femur. The diameter and length of the nails depends on the type of fracture. 1) Three nails of 4 mm diameter are introduced in parallel from the medial condyle in fractures of the femoral neck; 2) 5 mm nails are used, in similar fashion, for the fixation of intertrochanteric and subtrochanteric fractures; 3) 5 mm nails are used for diaphyseal, supracondylar and intercondylar fractures, introduced in crossed fashion ("Eiffel Tower" technique) from both medial and lateral condyles. This method of fixation has proved to be extremely stable. The operation itself is quick, with no blood loss or shock. The patient can resume partial weight bearing after a week in stabilised intertrochanteric and shaft fractures, after a month in less stable types, and after three to four months in fractures of the neck of the femur. This report is based on the first 250 cases treated by this method.

  11. Complications and functional recovery in treatment of femoral shaft fractures with unreamed intramedullary nailing.

    PubMed

    Sadic, Sahmir; Custovic, Svemir; Smajic, Nedim; Fazlic, Mirsad; Vujadinovic, Aleksandar; Hrustic, Asmir; Jasarevic, Mahir

    2014-01-01

    Fracture of the femoral shaft is a common fracture encountered in orthopedic practice. In the 1939, Küntscher introduced the concept of intramedullary nailing for stabilization of long bone fractures. Intramedullary nailing has revolutionized the treatment of fractures. The study included 37 male patients and 13 female patients, averaged 39 +/- 20.5 years (range, 16 to 76 years). There were 31 left femurs and 21 right femurs fractured. 46 fractures were the result of blunt trauma. Low energy trauma was the cause of fractures in six patients, of which five in elderly females. 49 fractures were closed. Healing time given in weeks was 19.36 +/- 6.1. The overall healing rate was 93.6%. There were three (6.25%) major complications nonunion. There were one (2%) delayed union, one (2%) rotational malunion and no infection. The shortening of 1 cm were in two patients. Antercurvatum of 10 degrees was found in one patient. There was no statistically significant reduction of a motion in the hip and knee (p < 0.05). There was statistically significant in the thigh (knee extensors) muscle weakness (p < 0.001). : Intramedullary nailing is the treatment of choice for femoral shaft fractures.

  12. Complications and Functional Recovery in Treatment of Femoral Shaft Fractures with Unreamed Intramedullary Nailing

    PubMed Central

    Sadic, Sahmir; Custovic, Svemir; Smajic, Nedim; Fazlic, Mirsad; Vujadinovic, Aleksandar; Hrustic, Asmir; Jasarevic, Mahir

    2014-01-01

    ABSTRACT Introduction: Fracture of the femoral shaft is a common fracture encountered in orthopedic practice. In the 1939, Küntscher introduced the concept of intramedullary nailing for stabilization of long bone fractures. Intramedullary nailing has revolutionized the treatment of fractures. Material and methods: The study included 37 male patients and 13 female patients, averaged 39±20,5 years (range, 16 to 76 years). Results and discussion: There were 31 left femurs and 21 right femurs fractured. 46 fractures were the result of blunt trauma. Low energy trauma was the cause of fractures in six patients, of which five in elderly females. 49 fractures were closed. Healing time given in weeks was 19,36 ± 6,1. The overall healing rate was 93,6%. There were three (6,25%) major complications nonunion. There were one (2%) delayed union, one (2%) rotational malunion and no infection. The shortening of 1 cm were in two patients. Antercurvatum of 10 degrees was found in one patient. There was no statistically significant reduction of a motion in the hip and knee (p<0.05). There was statistically significant in the thigh (knee extensors) muscle weakness (p<0.001). Conclusion: Intramedullary nailing is the treatment of choice for femoral shaft fractures. PMID:24783908

  13. Femoral neck shaft angle in men with fragility fractures.

    PubMed

    Tuck, S P; Rawlings, D J; Scane, A C; Pande, I; Summers, G D; Woolf, A D; Francis, R M

    2011-01-01

    Introduction. Femoral neck shaft angle (NSA) has been reported to be an independent predictor of hip fracture risk in men. We aimed to assess the role of NSA in UK men. Methods. The NSA was measured manually from the DXA scan printout in men with hip (62, 31 femoral neck and 31 trochanteric), symptomatic vertebral (91), and distal forearm (67) fractures and 389 age-matched control subjects. Age, height, weight, and BMD (g/cm(2): lumbar spine, femoral neck, and total femur) measurements were performed. Results. There was no significant difference in mean NSA between men with femoral neck and trochanteric hip fractures, so all further analyses of hip fractures utilised the combined data. There was no difference in NSA between those with hip fractures and those without (either using the combined data or analysing trochanteric and femoral neck shaft fractures separately), nor between fracture subjects as a whole and controls. Mean NSA was smaller in those with vertebral fractures (129.2° versus 131°: P = 0.001), but larger in those with distal forearm fractures (129.8° versus 128.5°: P = 0.01). Conclusions. The conflicting results suggest that femoral NSA is not an important determinant of hip fracture risk in UK men.

  14. Randomized, controlled, two-arm, interventional, multicenter study on risk-adapted damage control orthopedic surgery of femur shaft fractures in multiple-trauma patients.

    PubMed

    Rixen, Dieter; Steinhausen, Eva; Sauerland, Stefan; Lefering, Rolf; Maegele, Marc G; Bouillon, Bertil; Grass, Guido; Neugebauer, Edmund A M

    2016-01-25

    Long bone fractures, particularly of the femur, are common in multiple-trauma patients, but their optimal management has not yet been determined. Although a trend exists toward the concept of "damage control orthopedics" (DCO), current literature is inconclusive. Thus, a need exists for a more specific controlled clinical study. The primary objective of this study was to clarify whether a risk-adapted procedure for treating femoral fractures, as opposed to an early definitive treatment strategy, leads to an improved outcome (morbidity and mortality). The study was designed as a randomized controlled multicenter study. Multiple-trauma patients with femur shaft fractures and a calculated probability of death of 20 to 60 % were randomized to either temporary fracture fixation with external fixation and defined secondary definitive treatment (DCO) or primary reamed nailing (early total care). The primary objective was to reduce the extent of organ failure as measured by the maximum sepsis-related organ failure assessment (SOFA) score. Thirty-four patients were randomized to two groups of 17 patients each. Both groups were comparable regarding sex, age, injury severity score, Glasgow Coma Scale, prothrombin time, base excess, calculated probability of death, and other physiologic variables. The maximum SOFA score was comparable (nonsignificant) between the groups. Regarding the secondary endpoints, the patients with external fixation required a significantly longer ventilation period (p = 0.049) and stayed on the intensive care significantly longer (p = 0.037), whereas the in-hospital length of stay was balanced for both groups. Unfortunately, the study had to be terminated prior to reaching the anticipated sample size because of unexpected low patient recruitment. Thus, the results of this randomized study reflect the ambivalence in the literature. No advantage of the damage control concept could be detected in the treatment of femur fractures in multiple

  15. Adherence to oral bisphosphonates and the risk of subtrochanteric and femoral shaft fractures among female medicare beneficiaries

    PubMed Central

    Wang, Z.; Ward, M. M.; Chan, L.

    2014-01-01

    Summary Previous studies have shown an association between duration of bisphosphonate use and atypical femur fractures. This cohort study showed an increasingly higher risk of subtrochanteric and femoral shaft fractures among those who were more adherent to oral bisphosphonates. Introduction Long-term use of oral bisphosphonates has been implicated in an increased risk of atypical femur fractures located in subtrochanteric and femoral shaft regions. Another measure of drug exposure, medication adherence, however, has not been investigated. Methods Among all Medicare fee-for-service female beneficiaries from 2006–2010, we followed 522,287 new bisphosphonate users from their index prescription until being censored or having a primary diagnosis of closed subtrochanteric/ femoral shaft or intertrochanteric/femoral neck fractures. Data about radiographs of fracture site and features were not available. Adherence was classified according to the medication possession ratio (MPR) as the following: MPR<1/3 as less compliant, MPR≥1/3–<2/3 as compliant, and MPR≥2/3 as highly compliant. Alternative cutoff points at 50 and 80 % were also used. Survival analysis was used to determine the cumulative incidence and hazard of subtrochanteric/femoral shaft or intertrochanteric/femoral neck fractures. Results There was a graded increase in incidence of subtrochanteric/femoral shaft fractures as the level of adherence increased (Gray’s test, P<0.001). The adjusted hazard ratio (HR) for the highly compliant vs. the less compliant was 1.23 (95 % Confidence Interval [CI] 1.06–1.43) overall, became significant after 2 years of follow-up (HR=1.51, 95 % CI 1.06–2.15) and reached the highest risk in the fifth year (HR=4.06, 95 % CI 1.47–11.19). However, age-adjusted incidence rates of intertrochanteric/femoral neck fractures were significantly lower among highly compliant beneficiaries, compared to less compliant users (HR=0.69, 95 % CI 0.66–0.73). Similar results were

  16. Nontraumatic femur fracture in an oligomenorrheic athlete.

    PubMed

    Dugowson, C E; Drinkwater, B L; Clark, J M

    1991-12-01

    Exercise-associated amenorrhea is the cessation of menses in a woman following onset of training or an increase in training intensity. Its physiologic basis is characterized by consistently low levels of gonadotropin and ovarian hormones, but the underlying cause of this phenomenon is unknown. Although osteopenia has been described in amenorrheic women athletes, it has been primarily a laboratory diagnosis. Several recent studies have described a significantly lower bone mineral density (BMD) in the lumbar spine of amenorrheic athletes. Marcus et al. also reported an increased number of metatarsal and tibial stress fractures in a group of amenorrheic women. We report here the first case of a nontraumatic femur fracture in an amenorrheic athlete. A 32-yr-old white female, with four prior fibular stress fractures, suffered a left femoral shaft fracture during the 13th mile of a half-marathon. The fracture was successfully internally fixed. Biochemical studies showed no metabolic abnormality. Bone mineral density of the lumbar spine, femoral neck, tibia, and fibula were below the mean for both eumenorrheic and amenorrheic female athletes. Exercise-associated amenorrhea is a medical problem that may have serious implications for both competitive and high-intensity recreational female athletes.

  17. Secondary Radial Nerve Palsy after Minimally Invasive Plate Osteosynthesis of a Distal Humeral Shaft Fracture

    PubMed Central

    Bichsel, Ursina; Nyffeler, Richard Walter

    2015-01-01

    Minimally invasive plate osteosynthesis is a widely used procedure for the treatment of fractures of the femur and the tibia. For a short time it is also used for the treatment of humeral shaft fractures. Among other advantages, the ambassadors of this technique emphasize the lower risk of nerve injuries when compared to open reduction and internal fixation. We report the case of secondary radial nerve palsy caused by percutaneous fixation of a plate above the antecubital fold. The nerve did not recover and the patient needed a tendon transfer to regain active extension of the fingers. This case points to the importance of adequate exposure of the bone and plate if a humeral shaft fracture extends far distally. PMID:26558125

  18. Incidence and epidemiology of tibial shaft fractures.

    PubMed

    Larsen, Peter; Elsoe, Rasmus; Hansen, Sandra Hope; Graven-Nielsen, Thomas; Laessoe, Uffe; Rasmussen, Sten

    2015-04-01

    The literature lacks recent population-based epidemiology studies of the incidence, trauma mechanism and fracture classification of tibial shaft fractures. The purpose of this study was to provide up-to-date information on the incidence of tibial shaft fractures in a large and complete population and report the distribution of fracture classification, trauma mechanism and patient baseline demographics. Retrospective reviews of clinical and radiological records. A total of 196 patients were treated for 198 tibial shaft fractures in the years 2009 and 2010. The mean age at time of fracture was 38.5 (21.2SD) years. The incidence of tibial shaft fracture was 16.9/100,000/year. Males have the highest incidence of 21.5/100,000/year and present with the highest frequency between the age of 10 and 20, whereas women have a frequency of 12.3/100,000/year and have the highest frequency between the age of 30 and 40. AO-type 42-A1 was the most common fracture type, representing 34% of all tibial shaft fractures. The majority of tibial shaft fractures occur during walking, indoor activity and sports. The distribution among genders shows that males present a higher frequency of fractures while participating in sports activities and walking. Women present the highest frequency of fractures while walking and during indoor activities. This study shows an incidence of 16.9/100,000/year for tibial shaft fractures. AO-type 42-A1 was the most common fracture type, representing 34% of all tibial shaft fractures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. [Electromagnetic navigation interlocking intramedullary nail technology for treatment of femoral shaft fractures].

    PubMed

    Zuo, Kangkang; Qin, Wei; Guo, Qing; Palati-Ababaikeli; Qiao, Peiliu; Shen, Mingquan; Yin, Lele; Pan, Qilin; Xu, Xiaoxiong

    2014-10-01

    To explore the value of electromagnetic navigation interlocking intramedullary nail in the treatment of femoral shaft fracture. Between July 2012 and October 2013, 53 cases of femoral shaft fracture were treated. There were 40 males and 13 females, aged 16-52 years (mean, 38.3 years). The causes of injury were traffic accident in 28 cases, falling from height in 11 cases, falling in 7 cases, crush injury in 4 cases, and other in 3 cases. Of 53 cases, there were 3 cases of open fracture (Gustilo I degree) and 50 cases of closed fracture. Fracture was located in the proximal femur in 17 cases, middle femur in 29 cases, and distal femur in 7 cases. According to Winquist classification, 7 cases were rated as type I, 8 cases as type II, 22 cases as type III, and 16 cases as type IV; according to AO classification, 18 cases were rated as type 32-A, 28 cases as type 32-B, and 7 cases as type 32-C. The time from injury to operation was 3-11 days (mean, 5 days). Distal interlocking intramedullary nail was implanted using electromagnetic navigation. The distal locking nail operation with interlocking intramedullary nail was successfully completed under electromagnetic navigation; the one-time success rate of distal locking nail operation reached 100%; and the locking nail time was 5.0-9.5 minutes (mean, 7.0 minutes). Healing of incision by first intention was obtained after operation, and no complication of skin necrosis, infection, and sinus tract occurred. Fifty-three cases were all followed up 5-12 months (mean, 9 months). One case had hip pain and weaken middle gluteal muscle strength, and the symptoms disappeared after removing the nail. During the follow-up period, no broken nails, nail exit, infection, or re-fracture occurred. All fractures achieved clinical healing, and the healing time was 8-22 weeks (mean, 14.5 weeks). In 49 patients followed up 8 months, the Lysholm score was excellent in 44 cases, good in 4 cases, and acceptable in 1 case, with an excellent and

  20. Treatment of femoral shaft fractures with monoaxial external fixation in polytrauma patients

    PubMed Central

    Testa, Gianluca; Aloj, Domenico; Ghirri, Alessandro; Petruccelli, Eraclite; Pavone, Vito; Massé, Alessandro

    2017-01-01

    Background: Femoral shaft fractures, typical in younger people, are often associated with polytrauma followed by traumatic shock. In these situations, despite intramedullary nailing being the treatment of choice, external fixation could be used as the definitive treatment. The aim of this study is to report evidence regarding definitive treatment of femoral shaft fractures with monoaxial external fixation. Methods: Between January 2006 and December 2015, 83 patients with 87 fractures were treated at the Department of Orthopaedics and Traumatology CTO of Turin, with a monoaxial external fixation device. Mean age at surgery, type of fracture, mean follow-up, time and modalities of treatment, non-weight bearing period, average healing, external fixation removal time, and complications were reported. Results: The average patient age was 31.43±15.19 years. In 37 cases (42.53%) the right femur was involved. 73 (83.91%) fractures were closed, and 14 (16.09%) were open. The average follow-up time was 61.07±21.86 weeks.  In 68 (78.16%) fractures the fixation was carried out in the first 24 hours, using a monoaxial external fixator. In the remaining 19 cases, the average delay was 6.80±4.54 days. Mean non-weight bearing time was 25.82±27.66 days (ranging from 0 to 120). The 87 fractures united at an average of 23.60±11.37 weeks (ranging from 13 to 102). The external fixator was removed after an average of 33.99±14.33 weeks (ranging from 20 to 120). Reported complications included 9.19% of delayed union, 1.15% of septic non-union, 5.75% of malunion, and 8.05% cases of loss of reduction. Conclusions: External fixation of femoral shaft fractures in polytrauma is an ideal method for definitive fracture stabilization, with minimal additional operative trauma and an acceptable complication rate. PMID:28928953

  1. Rotational malalignment after closed intramedullary nailing of femoral shaft fractures and its influence on daily life.

    PubMed

    Karaman, Ozgur; Ayhan, Egemen; Kesmezacar, Hayrettin; Seker, Ali; Unlu, Mehmet Can; Aydingoz, Onder

    2014-10-01

    Any intraoperative rotational malalignment during intramedullary nailing (IMN) of femoral shaft fractures will become permanent. We hypothesized that rotational malalignment of the femur and its compensatory biomechanics may induce problems in the hip, knee, patellofemoral and ankle joints. We purposed to clarify the influence of a femoral rotational malalignment of ≥10° on daily activities. Twenty-four femoral shaft fracture patients treated with closed antegrade IMN were included. At last follow-up, to reveal any rotational malalignment, computerized tomography (CT) scans of both femurs (injured and uninjured sides) were examined. The patient groups with or without CT-detected true rotational malalignment ≥10° were compared with respect to the activity scores. Ten of the 24 patients (41.7%) had a CT-detected true rotational malalignment of ≥10° compared with the unaffected side. The AOFAS scores were 100.00 for all of the patients. LKS, WOMAC knee, and WOMAC hip scores were significantly decreased in the patients with rotational malalignment compared to those without. Patients without rotational malalignment tolerated climbing stairs significantly better than those with rotational malalignment. Patients who could not tolerate climbing stairs were consistently complaining of anterior knee pain. A femoral rotational malalignment of ≥10° is symptomatic for the patients, and the hip, knee, and patellofemoral joints were affected. Because of the possibly altered joint loadings and biomechanics, these could render patients prone to degenerative joint disease. In addition, due to the high rates of rotational malalignment after femoral shaft fracture and consequent malpractice claims, it is important for surgeons to be more aware of rotational alignment during surgery.

  2. Femur Fractures in Professional Athletes: A Case Series

    PubMed Central

    Sikka, Robby; Fetzer, Gary; Hunkele, Thomas; Sugarman, Eric; Boyd, Joel

    2015-01-01

    Objective: To discuss return to play after femur fractures in several professional athletes. Background: Femur fractures are rare injuries and can be associated with significant morbidity and mortality. No reports exist, to our knowledge, on return to play after treatment of isolated femur fractures in professional athletes. Return to play is expected in patients with femur fractures, but recovery can take more than 1 year, with an expected decrease in performance. Treatment: Four professional athletes sustained isolated femur fractures during regular-season games. Two athletes played hockey, 1 played football, and 1 played baseball. Three players were treated with anterograde intramedullary nails, and 1 was treated with retrograde nailing. All players missed the remainder of the season. At an average of 9.5 months (range, 7–13 months) from the time of injury, all athletes were able to return to play. One player required the removal of painful hardware, which delayed his return to sport. Final radiographs revealed that all fractures were well healed. No athletes had subjective complaints or concerns that performance was affected by the injury at an average final follow-up of 25 months (range, 22–29 months). Uniqueness: As the size and speed of players increase, on-field trauma may result in significant injury. All players returned to previous levels of performance or exceeded previous statistical performance levels. Conclusions: In professional athletes, return to play from isolated femur fractures treated with either an anterograde or retrograde intramedullary nail is possible within 1 year. Return to the previous level of performance is possible, and it is important to develop management protocols, including rehabilitation guidelines, for such injuries. However, return to play may be delayed by subsequent procedures, including hardware removal. PMID:25680071

  3. A biomechanical comparison of composite femurs and cadaver femurs used in experiments on operated hip fractures.

    PubMed

    Basso, Trude; Klaksvik, Jomar; Syversen, Unni; Foss, Olav A

    2014-12-18

    Fourth generation composite femurs (4GCFs, models #3406 and #3403) simulate femurs of males <80 years with good bone quality. Since most hip fractures occur in old women with fragile bones, concern is raised regarding the use of standard 4GCFs in biomechanical experiments. In this study the stability of hip fracture fixations in 4GCFs was compared to human cadaver femurs (HCFs) selected to represent patients with hip fractures. Ten 4GCFs (Sawbones, Pacific Research Laboratories, Inc., Vashon, WA, USA) were compared to 24 HCFs from seven females and five males >60 years. Proximal femur anthropometric measurements were noted. Strain gauge rosettes were attached and femurs were mounted in a hip simulator applying a combined subject-specific axial load and torque. Baseline measurements of resistance to deformation were recorded. Standardized femoral neck fractures were surgically stabilized before the constructs were subjected to 20,000 load-cycles. An optical motion tracking system measured relative movements. Median (95% CI) head fragment migration was 0.8mm (0.4 to 1.1) in the 4GCF group versus 2.2mm (1.5 to 4.6) in the cadaver group (p=0.001). This difference in fracture stability could not be explained by observed differences in femoral anthropometry or potential overloading of 4GCFs. 4GCFs failed with fracture-patterns different from those observed in cadavers. To conclude, standard 4GCFs provide unrealistically stable bone-implant constructs and fail with fractures not observed in cadavers. Until a validated osteopenic or osteoporotic composite femur model is provided, standard 4GCFs should only be used when representing the biomechanical properties of young healthy femurs. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Incidence of Avascular Necrosis of the Femoral Head After Intramedullary Nailing of Femoral Shaft Fractures

    PubMed Central

    Kim, Ji Wan; Oh, Jong-Keon; Byun, Young-Soo; Shon, Oog-Jin; Park, Jai Hyung; Oh, Hyoung Keun; Shon, Hyun Chul; Park, Ki Chul; Kim, Jung Jae; Lim, Seung-Jae

    2016-01-01

    Abstract The goal of this study was to determine the incidence of avascular necrosis of the femoral head (AVNFH) after intramedullary nailing of femoral shaft fractures and to identify risk factors for developing AVNFH. We retrospectively reviewed all patients with femoral shaft fractures treated with antegrade intramedullary nailing at 10 institutions. Among the 703 patients enrolled, 161 patients were excluded leaving 542 patients in the study. Average age was 42.1 years with average follow-up of 26.3 months. Patient characteristics and fracture patterns as well as entry point of femoral nails were identified and the incidence of AVNFH was investigated. Patients were divided into 2 groups according to open versus closed physis, open versus closed fractures, and age (<20 versus ≥20 years). Overall incidence of AVNFH was 0.2% (1 of 542): the patient was 15-year-old boy. Of 25 patients with open physis, the incidence of AVNFH was 4%, whereas none of 517 patients with closed physis developed AVNFH (P < 0.001). The incidence of AVNFH in patients aged < 20 versus ≥20 years was 1.1% (1 of 93) and 0.0% (0 of 449), respectively (P = 0.172), which meant that the incidence of AVNFH was 0% in adult with femur shaft fracture. Of 61 patients with open fractures, the incidence of AVNFH was 0%. The number of cases with entry point at the trochanteric fossa or tip of the greater trochanter (GT) was 324 and 218, respectively, and the incidence of AVNFH was 0.3% and 0.0%, respectively (P = 0.412). In patients aged ≥20 years with isolated femoral shaft fracture, there was no case of AVNFH following antegrade intramedullary nailing regardless of the entry point. Therefore, our findings suggest that the risk of AVNFH following antegrade femoral nailing is extremely low in adult patients. PMID:26844518

  5. Periprosthetic fractures of the femur after total knee arthroplasty.

    PubMed

    McGraw, Phil; Kumar, Arun

    2010-09-01

    Periprosthetic fracture following total knee arthroplasty is a potentially serious complication. This injury can involve the distal femur, proximal tibia or the patella. This review article analyzes the prevalence, risk factors, classification and treatment options for periprosthetic fractures of the femur.

  6. Dynamic Locked Plating of Distal Femur Fractures.

    PubMed

    Linn, Michael S; McAndrew, Christopher M; Prusaczyk, Beth; Brimmo, Olubusola; Ricci, William M; Gardner, Michael J

    2015-10-01

    Nonunion after locked bridge plating of comminuted distal femur fractures is not uncommon. "Dynamic" locked plating may create an improved mechanical environment, thereby achieving higher union rates than standard locked plating constructs. Academic Level 1 Trauma Center. Twenty-eight patients with comminuted supracondylar femur fractures treated with either dynamic or standard locked plating. Dynamic plating was achieved using an overdrilling technique of the near cortex to allow for a 0.5-mm "halo" around the screw shaft at the near cortex. Standard locked plating was done based on manufacturer's suggested technique. The patients treated with dynamic plating were matched 1:1 with those treated with standard locked plating based on OTA classification and working length. Three blinded observers made callus measurements on 6-week radiographs using a 4-point ordinal scale. The results were analyzed using a 2-tailed t test and 2-way intraclass correlations. The dynamic plating group had significantly greater callus (2.0; SD, 0.7) compared with the control group (1.3: SD, 0.8, P = 0.048) with substantial agreement amongst observers in both consistency (0.724) and absolute score (0.734). With dynamic plating group, 1 patient failed to unite, versus three in the control group (P = 0.59). The dynamic group had a mean change in coronal plane alignment of 0.5 degrees (SD, 2.6) compared with 0.6 (SD, 3.0) for the control group (P = 0.9) without fixation failure in either group. Overdrilling the near cortex in metaphyseal bridge plating can be adapted to standard implants to create a dynamic construct and increase axial motion. This technique seems to be safe and leads to increased callus formation, which may decrease nonunion rates seen with standard locked plating. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  7. The management of femur shaft fracture associated with severe traumatic brain injury.

    PubMed

    Mrozek, S; Gaussiat, F; Geeraerts, T

    2013-01-01

    The aim of this article is to describe the management of femoral shaft fractures in patients with severe traumatic brain injury (TBI). This is a major problem and two questions remain currently of interest: When and how to perform orthopedic surgery in severe TBI patients? The main point of perioperative management remains the prevention of secondary brain insults and the monitoring of intracranial pressure is essential especially in patients with intracranial lesions on the CT-scan. The "double hit" concept, suggesting that surgery by itself might increase the preexisting systemic inflammatory response, gives argument for very early or delayed surgery. Early definitive femoral osteosynthesis, if requires lengthy surgical procedure, does not seem appropriate in this context and "damage-control orthopedics" with external fixation seems to be a good alternative. Copyright © 2013. Published by Elsevier SAS.

  8. Single Stage Treatment of Non - Union of Transcervical Neck Femur Fracture with Shepherd Crook Deformity of Proximal Femur in A Case of Fibrous Dysplasia using Dynamic Hip Screw Fixation.

    PubMed

    Vk, Kandhari; Ss, Bava; Mm, Desai; Rn, Wade

    2015-01-01

    Fibrous dysplasia is a rare benign disorder of the skeletal system characterized by fibro osseous proliferation with intervening areas of normal or immature bone in the intramedullary region. It can either be a monostotic (involves one bone) or a polyostotic (involves more than one bone) presentation and usually occurs equally in males and females. Deformities like scoliosis and shepherd's crook deformity are frequently encountered in the polyostotic form. We report a rare managed case of bilateral non-union of the pathological fracture of femur neck with shepherd's crook deformity of the proximal femur in a case of polyostotic fibrous dysplasia. A 16 years old female case of polyostotic fibrous dysplasia had bilateral Shepherd's crook deformity of the proximal femur with bilateral non - union of pathological fracture of neck femur. We managed each side in one stage with two osteotomies. On the right side, first oblique osteotomy was done from just distal to the greater trochanter up to the level of the neck and the second; lateral closing wedge abduction osteotomy was done at the subtrochanteric level. 2 months later on the left side double lateral closing wedge abduction osteotomies were performed both at the subtrochanteric level. Fixation of both the sides was done using a 135° Dynamic Richard's screw with a long side plate to span the osteotomy sites and the lesion. Post - operatively we achieved a neck shaft angle of 135° on right side and 133° on the left side. Follow up imaging showed union at both the osteotomy sites bilaterally and also at the site of the pathological fracture of neck femur. Presently, at 18 months post - operatively, patient is walking full weight bearing without support and there are no signs of recurrence of lesions of fibrous dysplasia or the deformity. Double osteotomy is an easy and effective method to correct the shepherd's crook deformity and achieve correct mechanical alignment. Dynamic hip screw with long side plate is a

  9. Improving consent in patients undergoing surgery for fractured neck of femur.

    PubMed

    Thiruchandran, Gajendiran; McKean, Andrew R; Rudran, Branavan; Imam, Mohamed A; Yeong, Keefai; Hassan, Abdel

    2018-05-02

    Background Neck of femur fractures and their subsequent operative fixation are associated with high rates of perioperative morbidity and mortality. Consenting in this setting is suboptimal with the Montgomery court ruling changing the perspective of consent. This quality improvement project assessed the adequacy of consenting against British Orthopaedic Association-endorsed guidance and implemented a series of changes to improve the documentation of risks associated with surgery for fractured neck of femur. Methods Seventy consecutive patients who underwent any operative fixation of a neck of femur fracture were included over a 6-month period at a single centre. Patients unable to consent or without electronic notes were excluded. Consent forms were analysed and the documented potential risks or complications associated with surgery were compared to British Orthopaedic Association-endorsed guidance. A series of changes (using the plan, do study, act (PDSA) approach) was implemented to improve the adequacy of consent. Results Documentation of four out of 12 potential risks or complications was recorded in <50% of cases for patients with intracapsular fractures (n=35), and documentation of seven out of 12 potential risks or complications was recorded in <50% of cases for patients with extracapsular fractures (n=35). Re-audit following raising awareness and attaching consent guidance showed 100% documentation of potential risks or complications in patients with intracapsular and extracapsular fractures (n=70). A neck of femur fracture-specific consent form has been implemented which will hopefully lead to sustained improvement. Conclusions Consenting patients with fractured neck of femur for surgery in the authors' unit was suboptimal when compared to British Orthopaedic Association-endorsed consent guidance. This project has shown that ensuring such guidance is readily available has improved the adequacy of consent. The authors hope that introduction of a neck of

  10. Arthroscopic fixation of the clavicle shaft fracture.

    PubMed

    Kim, Yang-Soo; Lee, Hyo-Jin; Kim, Jong-Ick; Yang, Hyo; Jin, Hong-Ki; Patel, Hiren Kirtibhai; Kim, Jong-Ho; Park, In

    2017-01-01

    This article describes an arthroscopic technique for the fixation of clavicle shaft fractures. A viewing portal is made 2 cm anterior to the fracture site, and a working portal is made 2 cm lateral to the fracture site. The guide wire for a 4.0-mm cannulated screw is inserted through the fracture site to the medial fracture fragment under arthroscopic guidance. Through the medial fragment, the guide wire is delivered through the skin anteriorly. The fracture is reduced, and then, the guide wire is drilled back across the fracture site to the lateral fracture fragment. After confirming the reduction under arthroscopy, the appropriately sized cannulated screw is inserted after reaming. This arthroscopic technique would be useful for the precise reduction and minimal invasive fixation of clavicle shaft fractures. Preliminary results are encouraging, and further studies with long-term follow-up are needed to determine the precise indications and limitations of the procedure.

  11. Single Stage Treatment of Non – Union of Transcervical Neck Femur Fracture with Shepherd Crook Deformity of Proximal Femur in A Case of Fibrous Dysplasia using Dynamic Hip Screw Fixation

    PubMed Central

    VK, Kandhari; SS, Bava; MM, Desai; RN, Wade

    2015-01-01

    Introduction: Fibrous dysplasia is a rare benign disorder of the skeletal system characterized by fibro osseous proliferation with intervening areas of normal or immature bone in the intramedullary region. It can either be a monostotic (involves one bone) or a polyostotic (involves more than one bone) presentation and usually occurs equally in males and females. Deformities like scoliosis and shepherd’s crook deformity are frequently encountered in the polyostotic form. We report a rare managed case of bilateral non-union of the pathological fracture of femur neck with shepherd’s crook deformity of the proximal femur in a case of polyostotic fibrous dysplasia. Case Report: A 16 years old female case of polyostotic fibrous dysplasia had bilateral Shepherd’s crook deformity of the proximal femur with bilateral non – union of pathological fracture of neck femur. We managed each side in one stage with two osteotomies. On the right side, first oblique osteotomy was done from just distal to the greater trochanter up to the level of the neck and the second; lateral closing wedge abduction osteotomy was done at the subtrochanteric level. 2 months later on the left side double lateral closing wedge abduction osteotomies were performed both at the subtrochanteric level. Fixation of both the sides was done using a 135° Dynamic Richard’s screw with a long side plate to span the osteotomy sites and the lesion. Post – operatively we achieved a neck shaft angle of 135° on right side and 133° on the left side. Follow up imaging showed union at both the osteotomy sites bilaterally and also at the site of the pathological fracture of neck femur. Presently, at 18 months post – operatively, patient is walking full weight bearing without support and there are no signs of recurrence of lesions of fibrous dysplasia or the deformity. Conclusion: Double osteotomy is an easy and effective method to correct the shepherd’s crook deformity and achieve correct mechanical

  12. Interpretation of hip fracture patterns using areal bone mineral density in the proximal femur.

    PubMed

    Hey, Hwee Weng Dennis; Sng, Weizhong Jonathan; Lim, Joel Louis Zongwei; Tan, Chuen Seng; Gan, Alfred Tau Liang; Ng, Jun Han Charles; Kagda, Fareed H Y

    2015-12-01

    Bone mineral density scans are currently interpreted based on an average score of the entire proximal femur. Improvements in technology now allow us to measure bone density in specific regions of the proximal femur. The study attempts to explain the pathophysiology of neck of femur (NOF) and intertrochanteric/basi-cervical (IT) fractures by correlating areal BMD (aBMD) scores with fracture patterns, and explore possible predictors for these fracture patterns. This is a single institution retrospective study on all patients who underwent hip surgeries from June 2010 to August 2012. A total of 106 patients (44 IT/basi-cervical, 62 NOF fractures) were studied. The data retrieved include patient characteristics and aBMD scores measured at different regions of the contralateral hip within 1 month of the injury. Demographic and clinical characteristic differences between IT and NOF fractures were analyzed using Fisher's Exact test and two-sample t test. Relationship between aBMD scores and fracture patterns was assessed using multivariable regression modeling. After adjusted multivariable analysis, T-Troc and T-inter scores were significantly lower in intertrochanteric/basi-cervical fractures compared to neck of femur fractures (P = 0.022 and P = 0.026, respectively). Both intertrochanteric/basi-cervical fractures (mean T.Tot -1.99) and neck of femur fractures (mean T.Tot -1.64) were not found to be associated with a mean T.tot less than -2.5. However, the mean aBMD scores were consistently less than -2.5 for both intertrochanteric/basi-cervical fractures and neck of femur fractures. Gender and calcium intake at the time of injury were associated with specific hip fracture patterns (P = 0.002 and P = 0.011, respectively). Hip fracture patterns following low energy trauma may be influenced by the pattern of reduced bone density in different areas of the hip. Intertrochanteric/basi-cervical fractures were associated with significantly lower T-Troc and T-Inter scores

  13. Classification and treatment of periprosthetic supracondylar femur fractures.

    PubMed

    Ricci, William

    2013-02-01

    Locked plating and retrograde nailing are two accepted methods for treatment of periprosthetic distal femur fractures. Each has relative benefits and potential pitfalls. Appropriate patient selection and knowledge of the specific femoral component geometry are required to optimally choose between these two methods. Locked plating may be applied to most periprosthetic distal femur fractures. The fracture pattern, simple or comminuted, will dictate the specific plating technique, compression plating or bridge plating. Nailing requires an open intercondylar box and a distal fragment of enough size to allow interlocking. With proper patient selection and proper techniques, good results can be obtained with either method. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  14. Fracture of Human Femur Tissue Monitored by Acoustic Emission Sensors

    PubMed Central

    Aggelis, Dimitrios. G.; Strantza, Maria; Louis, Olivia; Boulpaep, Frans; Polyzos, Demosthenes; van Hemelrijck, Danny

    2015-01-01

    The study describes the acoustic emission (AE) activity during human femur tissue fracture. The specimens were fractured in a bending-torsion loading pattern with concurrent monitoring by two AE sensors. The number of recorded signals correlates well with the applied load providing the onset of micro-fracture at approximately one sixth of the maximum load. Furthermore, waveform frequency content and rise time are related to the different modes of fracture (bending of femur neck or torsion of diaphysis). The importance of the study lies mainly in two disciplines. One is that, although femurs are typically subjects of surgical repair in humans, detailed monitoring of the fracture with AE will enrich the understanding of the process in ways that cannot be achieved using only the mechanical data. Additionally, from the point of view of monitoring techniques, applying sensors used for engineering materials and interpreting the obtained data pose additional difficulties due to the uniqueness of the bone structure. PMID:25763648

  15. The efficacy of single-stage open intramedullary nailing of neglected femur fractures.

    PubMed

    Boopalan, P R J V C; Sait, Azad; Jepegnanam, Thilak Samuel; Matthai, Thomas; Varghese, Viju Daniel

    2014-02-01

    Neglected femur fractures are not rare in the developing world. Treatment options include single-stage open reduction and intramedullary nailing, or open release, skeletal traction, and then second-stage open intramedullary nailing, with bone grafting. Single-stage procedures have the potential advantage of avoiding neurovascular complications secondary to acute lengthening, but they require a second operation, with potentially increased resource use and infection risk. We sought to determine the (1) likelihood of union, (2) complications and reoperations, and (3) functional results with single-stage open intramedullary nailing without bone grafting in patients with neglected femur fractures. Between January 2003 and December 2007, 17 consecutive patients presented to our practice with neglected femoral shaft fractures. All were treated with single-stage nailing without bone grafting. There were 15 men and two women with a median age of 27 years. The average time from fracture to treatment was 13 weeks (range, 4-44 weeks). Eleven patients underwent open nailing with interlocked nails and six were treated with cloverleaf Kuntscher nails. Patients were followed for a minimum of 6 months (mean, 33 months; range, 6-72 months). The mean preoperative ROM of the knee was 28° (range, 10°-150°) and femoral length discrepancy was 3.1 cm (range, 1-5 cm). All fractures united and the mean time to union was 16 weeks (range, 7-32 weeks). There were no neurologic complications secondary to acute lengthening. The mean postoperative ROM of the knee was 130° (range, 60°-150°). All patients were able to return to preinjury work. Sixteen patients regained their original femoral length. One-stage open intramedullary nailing of neglected femoral diaphyseal fractures without bone grafting was safe and effective, and obviated the need for a two-stage approach. Although the findings need to be replicated in larger numbers of patients, we believe this technique may be useful in

  16. Proximal third humeral shaft fractures -- a fracture entity not fully characterized by conventional AO classification.

    PubMed

    Stedtfeld, H W; Biber, R

    2014-01-01

    The retrospective study was made to evaluate the fracture patterns at the proximal humeral shaft for which the long version of a standard proximal humeral nail (PHNLV) has been used. The indication has been decided by the individual surgeons. Over a five year period 72 consecutive PHNLV cases of an acute fracture were identified and were included in the study. Mean patient age was 68.9 years. Gender ratio was m/f=22/50. 86.1% of the patients fractured their humerus by a fall, the rest by a high velocity accident. We analysed patient comorbidity, ASA score, osteoporosis, social status before accident, additional injuries affecting local soft tissues or other anatomic regions. We analysed the expansion of the fractures, dividing the humerus into five zones. Fracture morphology was categorized according to the standard AO/ASIF classification (if applicable). Comorbidities were found in 76.4% of the patients. Almost all patients (93.1%) had been living independently at home before the accident. 47.2% of patients had osteoporosis in their medical history. Five patients (6.9%) had a primary palsy of the radial nerve. Six fractures chosen for PHNLV fixation were clearly restricted to the humeral head. The remaining 66 fractures were located in the humeral shaft (AO region 12). There were 5 segmental fractures. Of the remaining 67 fractures affecting the proximal third of the humeral shaft 49.3 percent extended into the humeral head. 98 percent of these fractures displayed spiral morphology. Proximal humeral shaft fractures are amazingly similar to subtrochanteric and distal tibial shaft fractures: Spiral fracture types with different grades of comminution are absolutely dominant; a great proportion of the fractures extend into the humeral head with growing tendency of displacement if located closer to the humeral head. Diverging traction of deltoid and pectoralis muscle causes typical displacement if the fracture line runs in between their attachments substantiating the

  17. Treatment of the femoral shaft fracture with a curved heat-treated COP clover-leaf nail.

    PubMed

    Onoue, Y; Sunami, Y; Fujiwara, H; Sadakane, T; Yasuda, S

    1979-01-01

    The commonly used straight intramedullary nail has certain limitations and disadvantages. Following radiographic and metallurgical studies we have developed a curved heat-treated clover-leaf nail using a newly developed precipitation hardening stainless steel (COP). The nail is bent with a slot on the convex side and the radius of curvature is 115 cm which corresponds to the anatomical antero-lateral convexity of the human femur. The nail has been satisfactory in clinical use since 1971 and has provided not only more stable internal fixation but also allowed fixation of fractures beyond the middle third of the shaft.

  18. A double-plating approach to distal femur fracture: A clinical study.

    PubMed

    Steinberg, Ely L; Elis, Jacov; Steinberg, Yohai; Salai, Moshe; Ben-Tov, Tomer

    2017-10-01

    Locked plating is one of the latest innovative options for treating supracondylar femur fractures with relatively low failure rates. Single lateral plating was often found to have a relative higher failure rate. No clinical studies of double-plating distal femur fixation have thus far been reported. The aim of this study is to present our clinical experience with this surgical approach. Thirty-two patients (26 females and 6 males, mean age 76 years, range 44-101) were included in the study. Eight of them patients had a periprosthetic stable implant fracture and two patients were treated for a nonunion. All fractures, excluding one that needed bone grafting and one refracture, healed within 12 weeks. One patient needed bone grafting for delayed union and one patient needed fixation exchange due to femur re-fracture at the site of the most proximal screw. Two patients developed superficial wound infection and one patient required medial plate removal after union due to deep infection. Based on these promising results, we propose that the double-plating technique should be considered in the surgeon's armamentarium for the treatment of supracondylar femur fractures, particularly in patients with poor bone quality, comminuted fractures and very low periprosthetic fractures. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. High revision rate but good healing capacity of atypical femoral fractures. A comparison with common shaft fractures.

    PubMed

    Schilcher, Jörg

    2015-12-01

    Healing of complete, atypical femoral fractures is thought to be impaired, but the evidence is weak and appears to be based on the delayed healing observed in patients with incomplete atypical fractures. Time until fracture healing is difficult to assess, therefore we compared the reoperation rates between women with complete atypical femoral fractures and common femoral shaft fractures. We searched the orthopaedic surgical registry in Östergötland County for patients with subtrochanteric and femoral shaft fractures (ICD-10 diagnosis codes S72.2, S72.3 and M84.3F) between January 1st 2007 and December 31st 2013. Out of 895 patients with surgically treated femoral shaft fractures, 511 were women 50 years of age or older. Among these we identified 24 women with atypical femoral shaft fractures, and 71 with common shaft fractures. Reoperations were performed in 6 and 5 patients, respectively, odds ratio 4.4 (95% CI 1.2 to 16.1). However, 5 reoperations in the atypical fracture group could not be ascribed to poor healing. In 3 patients the reoperation was due to a new fracture proximal to a standard intramedullary nail. In 2 patients the distal locking screws were removed due to callus formation that was deemed incomplete 5 months post-operatively. The one patient with poor healing showed faint callus formation at 5 months when the fracture was dynamised and callus remained sparse at 11 months. Among patients with common shaft fractures, 2 reoperations were performed to remove loose screws, 2 because of peri-implant fractures and 1 reoperation due to infection. Reoperation rates in patients with complete atypical femoral fractures are higher than in patients with common shaft fractures. The main reason for failure was peri-implant fragility fractures which might be prevented with the use of cephalomedullary nails at the index surgery. Fracture healing however, seems generally good. A watchful waiting approach is advocated in patients with fractures that appear to

  20. Comparison of tibial shaft ski fractures in children and adults.

    PubMed

    Hamada, Tomo; Matsumoto, Kazu; Ishimaru, Daichi; Sumi, Hiroshi; Shimizu, Katsuji

    2014-09-01

    To examine whether child and adult skiers have different risk factors or mechanisms of injury for tibial shaft fractures. Descriptive epidemiological study. Prospectively analyzed the epidemiologic factors, injury types, and injury mechanisms at Sumi Memorial Hospital. This study analyzed information obtained from 276 patients with tibial fractures sustained during skiing between 2004 and 2012. We focused on 174 ski-related tibial shaft fractures with respect to the following factors: age, gender, laterality of fracture, skill level, mechanism of fracture (fall vs collision), scene of injury (steepness of slope), snow condition, and weather. Fracture pattern was graded according to Arbeitsgemeinschaft für Osteosynthesefragen (AO) classification and mechanical direction [external (ER) or internal rotation (IR)]. Tibial shaft fractures were the most common in both children (89.3%) and adults (47.4%). There were no significant differences in gender, side of fracture, mechanism of fracture, snow condition, or weather between children and adults. Skill levels were significantly lower in children than in adults (P < 0.0001). Type A fractures were more dominant in children (73 cases, 72.3%) than in adults (39 cases, 53.4%). There was significantly more ER in children than in adults (P < 0.0001). Among children, female patients had significantly more IR than ER; in contrast, among adults, women were injured by ER. We found significant differences in some of these parameters, suggesting that child and adult skiers have different risk factors or mechanisms of injury for tibial shaft fractures.

  1. Compartment syndrome of the thigh complicating surgical treatment of ipsilateral femur and ankle fractures

    NASA Technical Reports Server (NTRS)

    Moore, M. R.; Garfin, S. R.; Hargens, A. R.

    1987-01-01

    A 26-year-old man presented with ipsilateral femur and ankle fractures. The patient was treated with interlocking nail of his femur fracture, followed by open reduction and internal fixation of his ankle fracture under tourniquet control. Postoperatively, the patient developed compartment syndrome of his thigh with elevated pressures, requiring decompressive fasciotomies. This case illustrates the possible complication of treating a femur fracture with intramedullary nailing and then immediately applying a tourniquet to treat an ipsilateral extremity fracture. Because of the complication with this patient, we feel the procedure should be staged, or a tourniquet should be avoided if possible.

  2. Femur Neck Fracture in a Young Marfan Syndrome Patient.

    PubMed

    Kwon, Yong-Uk; Kong, Gyu-Min; Park, Jun-Ho

    2016-12-01

    Marfan syndrome is an autosomal dominant and could decrease bone mineral density. So patients with Marfan syndrome could vulnerable to trauma in old ages. We present the first report, to the best of our knowledge, of a rare fracture of the femoral neck with a minor traumatic history in a juvenile Marfan syndrome patient whose physis is still open. Although the patient is young, her bone mineral density was low and the geometry of femur is changed like old ages. The femur neck fracture in children is very rare and only caused by high energy trauma, we concluded that the Marfan syndrome makes the bone weaker in young age and preventative medications to avoid fractures in younger Marfan syndrome patients are necessary in early ages.

  3. TIBIAL SHAFT FRACTURES.

    PubMed

    Kojima, Kodi Edson; Ferreira, Ramon Venzon

    2011-01-01

    The long-bone fractures occur most frequently in the tibial shaft. Adequate treatment of such fractures avoids consolidation failure, skewed consolidation and reoperation. To classify these fractures, the AO/OTA classification method is still used, but it is worthwhile getting to know the Ellis classification method, which also includes assessment of soft-tissue injuries. There is often an association with compartmental syndrome, and early diagnosis can be achieved through evaluating clinical parameters and constant clinical monitoring. Once the diagnosis has been made, fasciotomy should be performed. It is always difficult to assess consolidation, but the RUST method may help in this. Radiography is assessed in two projections, and points are scored for the presence of the fracture line and a visible bone callus. Today, the dogma of six hours for cleaning the exposed fracture is under discussion. It is considered that an early start to intravenous antibiotic therapy and the lesion severity are very important. The question of early or late closure of the lesion in an exposed fracture has gone through several phases: sometimes early closure has been indicated and sometimes late closure. Currently, whenever possible, early closure of the lesion is recommended, since this diminishes the risk of infection. Milling of the canal when the intramedullary nail is introduced is still a controversial subject. Despite strong personal positions in favor of milling, studies have shown that there may be some advantage in relation to closed fractures, but not in exposed fractures.

  4. FRACTURES OF THE FEMUR NECK RESULTING FROM RADIATION DAMAGE (in German)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koschitz-Kosic, H.

    Fractures of the neck of the femur following radiation therapy may involve three interrelated factors: age of the patient, archetectonic phylogenesis of the femur neck, and onset of radionecrosis. Up to now approximates 144 cases of femur neck fracture have been reported in the literature. Of the 10 cases reported here there was no clear relation between the time of irradiation and the fracture. One fracture followed 35 months after 17,400 r, and another 15 months after 4000 r of x ray, but both of these patients had also received Ra therapy. The average time span between irradiation and fracturemore » was 21 months. Only x ray had been given to five patients, but five had received combined x-ray and Ra treatment. One of the patients with a medial femur neck fracture became ambulatory after three weeks bed rest. The other nine fractures were nailed without any fatality. Subsequently, two cases were practically free of difficulties 12 and 18 months later, three cases exhibited slight fatigue 2, 5, and 63 months later, and five cases limped and required a cane 1, 3, 14, 17, and 76 months later. So far none of the nails have been removed. In no case was there complete recalcification of the fracture, and the ability of the ambulatory patients to walk depended on a combination of callus formation and the support of the nail. The fractures never gave any contraindication for use of the nails. Their use reduced the time for bed rest needed to an average of approximates 5 weeks. Treatment of this type of patient should also include appropriate geriatric and physical therapy measures. (BBB)« less

  5. Femur fractures should not be considered distracting injuries for cervical spine assessment.

    PubMed

    Dahlquist, Robert T; Fischer, Peter E; Desai, Harsh; Rogers, Amelia; Christmas, A Britton; Gibbs, Michael A; Sing, Ronald F

    2015-12-01

    The National Emergency X-Radiography Utilization Study (NEXUS) clinical decision rule is extremely sensitive for clearance of cervical spine (C-spine) injury in blunt trauma patients with distracting injuries. We sought to determine whether the NEXUS criteria would maintain sensitivity for blunt trauma patients when femur fractures were not considered a distracting injury and an absolute indication for diagnostic imaging. We retrospectively analyzed blunt trauma patients with at least 1 femur fracture who presented to our emergency department as trauma activations from 2009 to 2011 and underwent C-spine injury evaluation. Presence of C-spine injury requiring surgical intervention was evaluated. Of 566 trauma patients included, 77 (13.6%) were younger than 18 years. Cervical spine injury was diagnosed in 53 (9.4%) of 566. A total of 241 patients (42.6%) had positive NEXUS findings in addition to distracting injury; 51 (21.2%) of these had C-spine injuries. Of 325 patients (57.4%) with femur fractures who were otherwise NEXUS negative, only 2 (0.6%) had C-spine injuries (95% confidence interval [CI], 0.2%-2.2%); both were stable and required no operative intervention. Use of NEXUS criteria, excluding femur fracture as an indication for imaging, detected all significant injuries with a sensitivity for any C-spine injury of 96.2% (95% CI, 85.9%-99.3%) and negative predictive value of 99.4% (95% CI, 97.6%-99.9%). In our patient population, all significant C-spine injuries were identified by NEXUS criteria without considering the femur fracture a distracting injury and indication for computed tomographic imaging. Reconsidering femur fracture in this context may decrease radiation exposure and health care expenditure with little risk of missed diagnoses. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Pathological Fracture of the Femur by Metastatic Carcinoma Penis-a Rare Presentation.

    PubMed

    Hussain, Shabbir; Solanki, Fanindra Singh; Sharma, Deepti B; Sharma, Dhananjay

    2016-04-01

    We report herein a clinical case of a patient with femur fracture due to metastasis from penile squamous cell carcinoma. A young man, who was treated for carcinoma penis, presented with pathological fracture of femur and lung metastasis from metastatic carcinoma penis after 18 months. Long bone metastasis from penile cancer is extremely rare, to the best of our knowledge; this is the first report of a patient with penile cancer spread to the femur from primary squamous cell carcinoma of the penis.

  7. Use of anti-depressants and the risk of fracture of the hip or femur.

    PubMed

    van den Brand, M W M; Pouwels, S; Samson, M M; van Staa, T P; Thio, B; Cooper, C; Leufkens, H G M; Egberts, A C G; Verhaar, H J J; de Vries, F

    2009-10-01

    Anti-depressants are used largely, but have serious side effects. We show that both selective serotonin re-uptake inhibitors (SSRIs) and tricyclic anti-depressants (TCAs) increase the risk of hip/femur fracture and that this risk is time related and depends on the degree of serotonin transporter inhibition. This should be considered when prescribing anti-depressants to patients. Anti-depressants are known to have serious side effects. We examined the association between the use of anti-depressants and the risk of hip/femur fractures with a special focus on the relation with the degree of 5-hydroxytryptamine transporter (5-HTT) inhibition and the duration of use. A case-control study was conducted within the Dutch PHARMO-RLS database. Cases (n = 6,763) were adult patients with a first hip/femur fracture during the study period. For each case, four controls (n = 26341) were matched by age, gender and geographic region. The risk of hip/femur fracture increased with current use of SSRIs (adjusted odds ratio (OR(adj)) 2.35 [95% confidence interval (CI) 1.94-2.84]) and TCAs (ORadj 1.76 [95% CI 1.45-2.15]). The risk of hip/femur fracture declined rapidly after discontinuation of use. The risk of hip/femur fracture increased as the degree of 5-HTT inhibition of all anti-depressants increased from OR(adj) 1.64 [95% CI 1.14-2.35] for drugs with low 5-HTT inhibition to OR(adj) 2.31 [95% CI 1.94-2.76] for those with high 5-HTT inhibiting properties. Current use of both SSRIs and TCAs increase hip/femur fracture risk. Further studies are needed to elucidate the mechanistic pathways and the relation with the underlying pathophysiology. Until then, the elevated fracture risk should be considered when prescribing anti-depressants.

  8. Lateral drill holes decrease strength of the femur: an observational study using finite element and experimental analyses.

    PubMed

    Fox, Melanie J; Scarvell, Jennie M; Smith, Paul N; Kalyanasundaram, Shankar; Stachurski, Zbigniew H

    2013-08-30

    Internal fixation of femoral fractures requires drilling holes through the cortical bone of the shaft of the femur. Intramedullary suction reduces the fat emboli produced by reaming and nailing femoral fractures but requires four suction portals to be drilled into the femoral shaft. This work investigated the effect of these additional holes on the strength of the femur. Finite element analysis (FEA) was used to calculate compression, tension and load limits which were then compared to the results from mechanical testing. Models of intact femora and fractured femora internally fixed with intramedullary nailing were generated. In addition, four suction portals, lateral, anterior and posterior, were modelled. Stresses were used to calculate safety factors and predict fatigue. Physical testing on synthetic femora was carried out on a universal mechanical testing machine. The FEA model for stresses generated during walking showed tensile stresses in the lateral femur and compression stresses in the medial femur with a maximum sheer stress through the neck of the femur. The lateral suction portals produced tensile stresses up to over 300% greater than in the femur without suction portals. The anterior and posterior portals did not significantly increase stresses. The lateral suction portals had a safety factor of 0.7, while the anterior and posterior posts had safety factors of 2.4 times walking loads. Synthetic bone subjected to cyclical loading and load to failure showed similar results. On mechanical testing, all constructs failed at the neck of the femur. The anterior suction portals produced minimal increases in stress to loading so are the preferred site should a femur require such drill holes for suction or internal fixation.

  9. Effect of fragmentary displacement and morphology in the treatment of comminuted femoral shaft fractures with an intramedullary nail.

    PubMed

    Lin, Shih-Jie; Chen, Chi-Lung; Peng, Kuo-Ti; Hsu, Wei-Hsiu

    2014-04-01

    Our study aimed to determine whether the displacement and morphology of a fragment in femur fracture with Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association/32-B/32-C (AO/OTA/32-B/32-C) classification affect the outcomes following closed reduction and internal fixation with an interlocking nail. This was a retrospective study. The study was conducted at a Level III trauma centre. A total of 50 consecutive patients presenting femoral shaft fracture with AO/OTA-type 32-B/32-C were included in the present study. Patients were divided into two groups according to the displacement of the fragments. In the large displacement group, patients were further subgrouped according to whether a reversed morphology of the fragment was present. The radiographic union score of femur (RUSF), the mean union time and the re-operation rate were assessed. The union rate of small- and large-gap groups at 12 months postoperatively was 75.9% and 21.1%, respectively (p=0.000). The mean union time of those union cases in these two groups was 7.8 and 13.0 months, respectively (p=0.000). The union rate of the non-reversed and reversed groups at 12 months postoperatively was 30% and 11.1%, respectively (p=0.179). The mean RUSF at 12 months in the non-reversed and reversed groups was 8.8 and 8.3, respectively (p=0.590). However, we found that patients presenting a reversed fragment had an increased risk of more than one re-operation (p=0.030). A fragmentary displacement of >1cm in AO/OTA-type 32-B/32-C femoral shaft fracture after nailing affected bone healing. Among the large-gap group patients, an unreduced reverse fragment presented a negative prognostic factor for re-operation. Prognostic level III. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Measurement of bone adjacent to tibial shaft fracture.

    PubMed

    Findlay, S C; Eastell, R; Ingle, B M

    2002-12-01

    Delayed union and non-union are common complications after fracture of the tibial shaft. Response of the surrounding bone as a fracture heals could be monitored using techniques currently used in the study of osteoporosis. The aims of our study were to: (1) evaluate the decrement in bone measurements made close to the fracture using dual-energy X-ray absorptiometry (DXA), quantitative ultrasound (QUS) and peripheral quantitative computed tomography (pQCT); (2) compare values for fractured versus non-fractured leg to determine the duration of decrement in bone measurements; and (3) calculate short-term precision in DXA, QUS and pQCT in order to calculate the ratio of decrement to precision (response ratio, RR) to determine the optimal test for monitoring changes after tibial fracture. The biggest decrement in bone measurements at the ipsilateral limb of 28 patients with tibial shaft fracture was observed at the pQCT tibial trabecular sites (distal = 19%, p<0.0001; proximal 5% = 21%, p<0.001; proximal 10% = 28%, p<0.001) and the ultradistal tibia/fibula measured by DXA (19%, p<0.0001). When comparing Z-scores, the magnitude of decrements at the ipsilateral limb was bigger for variables measured directly at the tibia, both proximal and distal to the fracture. The magnitude of the decrement in ultradistal tibia/fibula BMD decreased as the time since fracture increased ( r = 0.55). When response ratios are considered, pQCT measurements at the distal tibia (RR 6-8) and proximal 5% and 10% trabecular sites (RR 5 and 9 respectively) were found to be the most sensitive to change. Therefore, pQCT of the trabecular regions of either the proximal or distal tibia should prove the most sensitive measurement for monitoring changes in bone adjacent to a tibial shaft fracture.

  11. Mortality and Financial Burden of Periprosthetic Fractures of the Femur.

    PubMed

    Shields, Edward; Behrend, Caleb; Bair, Jeff; Cram, Peter; Kates, Stephen

    2014-12-01

    This study examines patient factors to identify risks of 12-month mortality following periprosthetic femur fractures. Hospital charges were analyzed to quantify the financial burden for treatment modalities. Data were retrospectively analyzed from a prospective database at a university hospital setting. One-hundred and thirteen patients with a periprosthetic fracture of the proximal or distal femur were identified. Risk factors for 12-month mortality were analyzed, and financial data were compared between the various treatment modalities. In all, 14% of patients died (16 of 113) within 3 months and the 1-year mortality was 17.7% (20 of 113). Patients who died within 1 year had higher hospital charges (US$33 880 ± 25 051 vs US$22 886 ± 16 841; P = .01) and were older (87.6 ± 8.5 vs 81.5 ± 8.6; P = .004). Logistic regression analysis revealed age was the only significant predictor of 1-year mortality (P = .029, odds ratio 1.1). Analysis of financial data revealed 4 distinct groups (P < .05 between groups). Distal femoral revision arthroplasty (RA-DF) generated the highest hospital charges of US$91 035 ± 25 579 (n = 3). The second most highly charged group included proximal femoral fractures treated with revision arthroplasty (US$34 078 ± 17 832; n = 20) and hemi/total hip arthroplasty (THA; US$41 556 ± 23 651; n = 8). The third most charged group underwent open reduction internal fixation of the proximal (US$18 706 ± 6829; n = 35) and distal (US$22 381 ± 10 835; n = 35) femur. Nonoperative treatment generated the lowest charges (US$6426 ± 2899; n = 11). On average, the hospital lost money treating patients with RA-DF (US$-19 080 ± 2022 per patient) and hemi/THA (US$-6594 ± 9305 per patient), while all other treatment groups were profitable. One-year mortality after periprosthetic femur fractures was 17.7%, is mostly influenced by age, and 80% of deaths occur within 3 months. Patients treated with primary/revision arthroplasty generate more hospital

  12. Ipsilateral femoral shaft and vertical patella fracture: a case report

    PubMed Central

    Ozkan, Korhan; Eceviz, Engin; Sahin, Adem; Ugutmen, Ender

    2009-01-01

    Introduction A femoral shaft fracture with an ipsilateral patella fracture has been, to our knowledge, given only cursory attention in English-speaking literature. Case presentation A 15 year old male patient had hitten by a car to his motorcycle came to emergency room and he had been operated for his femoral shaft freacture and vertical patellar fracture which was iniatally missed. Conclusion To us it is vital to obtain CT scan of the patient’s knee if there is an ipsilateral femoral fracture with an ipsilateral knee effusion and a punction which reveals hematoma even in the absence of a fracture line seen in AP and lateral projections. PMID:19829933

  13. Comparison of submuscular and open plating of pediatric femur fractures: a retrospective review.

    PubMed

    Abbott, Matthew D; Loder, Randall T; Anglen, Jeffrey O

    2013-01-01

    Plate osteosynthesis is an accepted method of treatment of pediatric femur fractures. Historically, open plating has been used. Submuscular bridge plating has gained recent popularity due to the theoretical advantages of decreased operative time, decreased blood loss, and decreased risk for infection. The purpose of this study was to compare submuscular bridge plating to open plating of pediatric femur fractures. We retrospectively reviewed 79 patients (80 treated femur fractures) between 1999 and 2011 that underwent either open plating (58 femur fractures) or submuscular bridge plating (22 femur fractures). The outcome measures evaluated were operative time, estimated blood loss, malunion, leg length discrepancy, time to union, infection, unplanned return to the operating room, and length of hospital stay after surgery. Among our outcome measures, there was no difference between the 2 groups in terms of operative time, leg length discrepancy, time to union, infection, or length of hospital stay after surgery. There was greater estimated blood loss in the open plating group (P≤0.0001) and greater rotational asymmetry in the submuscular bridge plating group (P=0.005). There was a trend of increased unplanned return to the operating room in the open plating group (5/58 vs. 0/22) although not statistically significant (P=0.32). Submuscular bridge plating and open plating seem to be equally viable options for the management of pediatric diaphyseal femur fractures. In this study, open plating had an increase in estimated blood loss and a trend of more unplanned returns to the operating room, whereas submuscular bridge plating had an increase in asymptomatic rotational asymmetry. Further larger, prospective, randomized studies are necessary to further evaluate these operative techniques. Therapeutic Level III.

  14. Minimizing Leg Length Discrepancy After Intramedullary Nailing of Comminuted Femoral Shaft Fractures: A Quality Improvement Initiative Using the Scout Computed Tomography Scanogram.

    PubMed

    Gheraibeh, Petra; Vaidya, Rahul; Hudson, Ian; Meehan, Robert; Tonnos, Frederick; Sethi, Anil

    2018-05-01

    To prevent leg length discrepancy (LLD) after locked femoral nailing in patients with comminuted femoral shaft fractures. Prospective consecutive case series aimed at quality improvement. Level 1 Trauma Center PATIENTS:: Ninety-eight consecutive patients with a comminuted femoral shaft fracture underwent statically locked intramedullary nailing, with a focused attempt at minimizing LLD during surgery. A computed tomography scanogram of both legs was performed on postoperative day 1 to assess for residual LLD. Patients were offered the option to have LLD >1.5 cm corrected before discharge. LLD >1.5 cm. Twenty-one patients (21.4%) were found to have an LLD >1.5 cm. An LLD >1.5 cm occurred in 10/55 (18%) antegrade nail patients and 11/43 (26%) retrograde nail patients (P = 0.27). No difference was noted based on the mechanism of injury, surgeon training and OTA/AO type B versus C injury. Ninety of 98 patients left with <1.5 cm LLD, 13/21 had a correction all to ≤0.6 cm, and 8 decided to accept the LLD and declined early correction. No patient left the hospital with an LLD >1.5 cm after locked intramedullary nailing for a comminuted femoral shaft fracture without being informed and the option of early correction. We recommend using a full-length computed tomography scanogram after IM nailing of comminuted femur fractures to prevent iatrogenic LLD. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  15. The tolerance of the femoral shaft in combined axial compression and bending loading.

    PubMed

    Ivarsson, B Johan; Genovese, Daniel; Crandall, Jeff R; Bolton, James R; Untaroiu, Costin D; Bose, Dipan

    2009-11-01

    The likelihood of a front seat occupant sustaining a femoral shaft fracture in a frontal crash has traditionally been assessed by an injury criterion relying solely on the axial force in the femur. However, recently published analyses of real world data indicate that femoral shaft fracture occurs at axial loads levels below those found experimentally. One hypothesis attempting to explain this discrepancy suggests that femoral shaft fracture tends to occur as a result of combined axial compression and applied bending. The current study aims to evaluate this hypothesis by investigating how these two loading components interact. Femoral shafts harvested from human cadavers were loaded to failure in axial compression, sagittal plane bending, and combined axial compression and sagittal plane bending. All specimens subjected to bending and combined loading fractured midshaft, whereas the specimens loaded in axial compression demonstrated a variety of failure locations including midshaft and distal end. The interaction between the recorded levels of applied moment and axial compression force at fracture were evaluated using two different analysis methods: fitting of an analytical model to the experimental data and multiple regression analysis. The two analysis methods yielded very similar relationships between applied moment and axial compression force at midshaft fracture. The results indicate that posteroanterior bending reduces the tolerance of the femoral shaft to axial compression and that that this type of combined loading therefore may contribute to the high prevalence of femoral shaft fracture in frontal crashes.

  16. Fractures of the Femur. End Results*

    PubMed Central

    2008-01-01

    guidance [5]. We reproduce here an article in which Dr. Henderson reviewed 222 consecutive cases of femur fractures, 165 of which had been referred late because of complications of fractures treated elsewhere (clearly, by 1921, the Mayo Clinic was a referral source for others) [2]. Followup could not have been easy at a time when patients often came from a distance and travel was difficult, but it was described when available and in 40 of the 57 recent fractures, Henderson reported 87.5% were “cured.” Of the 165 old fractures, he was able to trace 143 (87%), a remarkable figure even today. He reported 90% of the femoral neck fractures were cured by various sorts of nonsurgical (6 patients) or surgical reconstructive (39 patients) means; 85% of the femoral shaft fractures were cured by either nonoperative (29 patients) or operative (69 patients) means. While he did not use the sort of outcomes we use today (the earliest orthopaedic outcome instruments were not introduced for four more decades: by Carroll B. Larson in 1963 [3] and William H. Harris in 1969 [1]), we can only presume Henderson meant union was achieved when patients were “cured” since nonunion or malunion would not have likely produced good results. That being the case, his rate of union was remarkable and would be enviable today in these sometimes difficult situations, attesting to his understanding of the individual situations and his skills. Melvin S. Henderson, MD is shown. Photograph is reproduced with permission and ©American Academy of Orthopaedic Surgeons. Fifty Years of Progress, 1983. References Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty: an end-result study using a new method of result evaluation. J Bone Joint Surg Am. 1969;51:737–755. Henderson MS. Fractures of the femur: end results. J Bone Joint Surg Am. 1921;3:520–528. Larson CB. Rating scale for hip disabilities. Clin Orthop Relat Res. 1963;31:85–93. Mostofi

  17. Biomechanical properties of the mid-shaft femur in middle-aged hypophysectomized rats as assessed by bending test.

    PubMed

    Bozzini, Clarisa; Picasso, Emilio O; Champin, Graciela M; Alippi, Rosa María; Bozzini, Carlos E

    2012-10-01

    Both stiffness and strength of bones are thought to be controlled by the "bone mechanostat". Its natural stimuli would be the strains of bone tissue (sensed by osteocytes) that are induced by both gravitational forces (body weight) and contraction of regional muscles. Body weight and muscle mass increase with age. Biomechanical performance of load-bearing bones must adapt to these growth-induced changes. Hypophysectomy in the rat slows the rate of body growth. With time, a great difference in body size is established between a hypophysectomized rat and its age-matched control, which makes it difficult to establish the real effect of pituitary ablation on bone biomechanics. The purpose of the present investigation was to compare mid-shaft femoral mechanical properties between hypophysectomized and weight-matched normal rats, which will show similar sizes and thus will be exposed to similar habitual loads. Two groups of 10 female rats each (H and C) were established. H rats were 12-month-old that had been hypophysectomized 11 months before. C rats were 2.5-month-old normals. Right femur mechanical properties were tested in 3-point bending. Structural (load-bearing capacity and stiffness), geometric (cross-sectional area, cortical sectional area, and moment of inertia), and material (modulus of elasticity and maximum elastic stress) properties were evaluated. The left femur was ashed for calcium content. Comparisons between parameters were performed by the Student's t test. Average body weight, body length, femur weight, femur length, and gastrocnemius weight were not significantly different between H and C rats. Calcium content in ashes was significantly higher in H than in C rats. Cross-sectional area, medullary area, and cross-sectional moment of inertia were higher in C rats, whereas cortical area did not differ between groups. Structural properties (diaphyseal stiffness, elastic limit, and load at fracture) were about four times higher in hypophysectomized rats

  18. Case reports: A subtrochanteric femur fracture with long intramedullary femorotibial nail for knee arthrodesis.

    PubMed

    Torga-Spak, Roger; Gugala, Zbigniew; Lindsey, Ronald W

    2006-03-01

    We present a case report of a patient who had a transverse subtrochanteric femur fracture develop 2 months after uneventful placement of a long femorotibial intramedullary nail for knee arthrodesis. To date, diaphyseal fracture of a femur already stabilized with an intramedullary nail has not been reported. The possible etiology for this unusual complication is discussed.

  19. Avoidance of malreduction of proximal femoral shaft fractures with the use of a minimally invasive nail insertion technique (MINIT).

    PubMed

    Russell, Thomas A; Mir, Hassan R; Stoneback, Jason; Cohen, Jose; Downs, Brandon

    2008-07-01

    To determine our rate of malalignment in proximal femoral shaft fractures treated with intramedullary (IM) nails, with and without the use of a minimally invasive nail insertion technique (MINIT). Retrospective study. Level 1 trauma center. Between July 1, 2003, and June 31, 2005, 100 consecutive proximal femoral shaft fractures (97 patients) were treated with IM nails. The average age of the 56 men and 41 women was 43.5 years (range, 17 to 96 years). There were 92 closed fractures and 8 open fractures. Fractures were classified according to the Russell-Taylor classification (69 type 1A, 11 type 1B, 3 type 2A, 17 type 2B). All patients underwent antegrade IM nailing using a fracture table in the supine (83) or lateral (17) position. A total of 72 entry portals were trochanteric, and 28 were piriformis. Seventy-seven percent of the femurs were opened with MINIT, a technique that uses a percutaneous cannulated channel reamer over a guide pin as opposed to the standard method of Kuntscher, which employs a femoral awl. Nails were locked proximally using standard locking in 37 fractures, and recon mode in 63. Fracture reduction was examined on immediate postoperative films to determine angulation in the coronal and sagittal planes. Criteria for acceptable reduction were less than 5 degrees angulation in any plane. In addition, surgical position, entry portal, mechanism of injury, Russell-Taylor classification, OTA classification, open or closed fracture, open or closed reduction, and type of implant used were analyzed for significance. The frequency of malalignment was 10% for the entire group of patients. Malalignment occurred in 26% of fractures treated without the use of the MINIT and in 5.2% when the MINIT was used (P < 0.01). There was no statistically significant difference between the different Russell-Taylor fracture types, although there was a trend towards more malalignment in type 2A and 2B fractures (P = 0.06). None of the other factors studied had a

  20. Systemic Delivery of Free Chitosan Accelerates Femur Fracture Healing in Rats.

    PubMed

    Shao, Peng; Wei, Yongzhong; Dass, Crispin R; Zhang, Guoying; Wu, Zhisheng

    2018-01-01

    Chitosan-containing compounds have been shown to be suitable for bone replacement, but few studies demonstrate the impact of the chitosan as a free drug on the fracture.In this study, we aimed to evaluate possible effects of free chitosan on fracture healing. Thirty adult male Sprague-Dawley rats with a mean body weight of 205 g (range from 200g to 210g) were randomly and equally divided into two groups. Standardized femur fractures were created in all rats. Treatments were administered intraperitoneally twice weekly at 1 mg chitosan per injection and the controls were administered physiological saline. The site of the fracture was compared with the control group at 1, 2 and 4 weeks after surgery (n=5 in each group). The weight, activity and reaction of the rats were observed at all the timepoints. Anterior-posterior radiographs and micro-CT scans of all fractures were taken after surgery, and the parameters included: the volume of callus that was calculated using the Perkins volume formula, BV/TV, BV, BMD of cortical bone, cortical thickness, and cortical number at the fracture sites. After sacrifice, fractured femurs from rats were dissected and carefully cleaned of muscle around the fracture callus to preserve callus integrity. Sections were stained with haematoxylin and eosin for histological evaluation of healing. Radiological (X-ray and micro-CT) evaluation showed that fracture healing of the experimental group was better than control group at the second week and fourth week. Histological evaluation revealed fracture healing of the experimental group was better than control group at the same time. There was no statistically significant difference in fracture healing between the two groups at the first week. Systemic delivery of free chitosan can accelerate the bone healing process in rat femur fracture at the early-middle stage. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  1. Return to Sport After Tibial Shaft Fractures

    PubMed Central

    Robertson, Greg A. J.; Wood, Alexander M.

    2015-01-01

    Context: Acute tibial shaft fractures represent one of the most severe injuries in sports. Return rates and return-to-sport times after these injuries are limited, particularly with regard to the outcomes of different treatment methods. Objective: To determine the current evidence for the treatment of and return to sport after tibial shaft fractures. Data Sources: OVID/MEDLINE (PubMed), EMBASE, CINAHL, Cochrane Collaboration Database, Web of Science, PEDro, SPORTDiscus, Scopus, and Google Scholar were all searched for articles published from 1988 to 2014. Study Selection: Inclusion criteria comprised studies of level 1 to 4 evidence, written in the English language, that reported on the management and outcome of tibial shaft fractures and included data on either return-to-sport rate or time. Studies that failed to report on sporting outcomes, those of level 5 evidence, and those in non–English language were excluded. Study Design: Systematic review. Level of Evidence: Level 4. Data Extraction: The search used combinations of the terms tibial, tibia, acute, fracture, athletes, sports, nonoperative, conservative, operative, and return to sport. Two authors independently reviewed the selected articles and created separate data sets, which were subsequently combined for final analysis. Results: A total of 16 studies (10 retrospective, 3 prospective, 3 randomized controlled trials) were included (n = 889 patients). Seventy-six percent (672/889) of the patients were men, with a mean age of 27.7 years. Surgical management was assessed in 14 studies, and nonsurgical management was assessed in 8 studies. Return to sport ranged from 12 to 54 weeks after surgical intervention and from 28 to 182 weeks after nonsurgical management (mean difference, 69.5 weeks; 95% CI, –83.36 to −55.64; P < 0.01). Fractures treated surgically had a return-to-sport rate of 92%, whereas those treated nonsurgically had a return rate of 67% (risk ratio, 1.37; 95% CI, 1.20 to 1.57; P < 0

  2. Lateral Cortical Thickening and Bone Heterogeneity of the Subtrochanteric Femur Measured With Quantitative CT as Indicators for Early Detection of Atypical Femoral Fractures in Long-Term Bisphosphonate Users.

    PubMed

    Lee, Seung Hyun; Lee, Young Han; Suh, Jin-Suck

    2017-10-01

    The objective of our study was to compare subtrochanteric femur bone mineral density (BMD) and bone quality of long-term bisphosphonate (BP) users who sustained an atypical femoral fracture (AFF) with BP users who did not sustain a femoral fracture and BP-naïve patients with no history of femoral fracture using quantitative CT (QCT). Fourteen female BP users with an AFF (mean age, 72.6 years; mean duration of BP use, 6.2 years; mean body mass index, 21.9) who had undergone QCT before fracture events were sex-, age-, BP use duration-, and body mass index-matched to 14 BP users who did not sustain a fracture and 14 BP-naïve patients. The lateral cortical thickness index (CTI) and the mean BMD (BMD mean ) and SD of the BMD (BMD SD ) within the lateral cortex and within the entire cross-sectional area of the subtrochanteric femur were measured on axial QCT. Femoral neck-shaft angles were measured on the QCT scout image. Parameters were analyzed using the Kruskal-Wallis test. Lateral CTIs were greater in the BP users with an AFF (median, 0.28) than in the BP users without a femoral fracture (median, 0.21) (p = 0.038) and the BP-naïve group (median, 0.21) (p = 0.009). The lateral cortex BMD SD was significantly higher in the BP users with an AFF (median, 59.59 mg/cm 3 ) than the BP users without a femoral fracture (median, 39.27 mg/cm 3 ; p = 0.049) and the BP-naïve group (median, 31.02 mg/cm 3 ; p = 0.037). There was no significant difference among groups in lateral cortex BMD mean , BMD mean and BMD SD of the entire cross-sectional area, and femoral neck-shaft angle. Long-term BP users with a subsequent AFF had a thicker lateral cortex and higher lateral cortex BMD SD at the subtrochanteric area before the fracture on QCT than BP users who did not sustain a femoral fracture and BP-naïve patients.

  3. Bisphosphonates and atypical subtrochanteric fractures of the femur

    PubMed Central

    Kharwadkar, N.; Mayne, B.; Lawrence, J. E.

    2017-01-01

    Objectives Bisphosphonates are widely used as first-line treatment for primary and secondary prevention of fragility fractures. Whilst they have proved effective in this role, there is growing concern over their long-term use, with much evidence linking bisphosphonate-related suppression of bone remodelling to an increased risk of atypical subtrochanteric fractures of the femur (AFFs). The objective of this article is to review this evidence, while presenting the current available strategies for the management of AFFs. Methods We present an evaluation of current literature relating to the pathogenesis and treatment of AFFs in the context of bisphosphonate use. Results Six broad themes relating to the pathogenesis and management of bisphosphonate-related AFFs are presented. The key themes in fracture pathogenesis are: bone microdamage accumulation; altered bone mineralisation and altered collagen formation. The key themes in fracture management are: medical therapy and surgical therapy. In addition, primary prevention strategies for AFFs are discussed. Conclusions This article presents current knowledge about the relationship between bisphosphonates and the development of AFFs, and highlights key areas for future research. In particular, studies aimed at identifying at-risk subpopulations and organising surveillance for those on long-term therapy will be crucial in both increasing our understanding of the condition, and improving population outcomes. Cite this article: N. Kharwadkar, B. Mayne, J. E. Lawrence, V. Khanduja. Bisphosphonates and atypical subtrochanteric fractures of the femur. Bone Joint Res 2017;6:144–153. DOI: 10.1302/2046-3758.63.BJR-2016-0125.R1. PMID:28288986

  4. Tibial shaft fractures in football players

    PubMed Central

    Chang, Winston R; Kapasi, Zain; Daisley, Susan; Leach, William J

    2007-01-01

    Background Football is officially the most popular sport in the world. In the UK, 10% of the adult population play football at least once a year. Despite this, there are few papers in the literature on tibial diaphyseal fractures in this sporting group. In addition, conflicting views on the nature of this injury exist. The purpose of this paper is to compare our experience of tibial shaft football fractures with the little available literature and identify any similarities and differences. Methods and Results A retrospective study of all tibial football fractures that presented to a teaching hospital was undertaken over a 5 year period from 1997 to 2001. There were 244 tibial fractures treated. 24 (9.8%) of these were football related. All patients were male with a mean age of 23 years (range 15 to 29) and shin guards were worn in 95.8% of cases. 11/24 (45.8%) were treated conservatively, 11/24 (45.8%) by Grosse Kemp intramedullary nail and 2/24 (8.3%) with plating. A difference in union times was noted, conservative 19 weeks compared to operative group 23.9 weeks (p < 0.05). Return to activity was also different in the two groups, conservative 27.6 weeks versus operative 23.3 weeks (p < 0.05). The most common fracture pattern was AO Type 42A3 in 14/24 (58.3%). A high number 19/24 (79.2%) were simple transverse or short oblique fractures. There was a low non-union rate 1/24 (4.2%) and absence of any open injury in our series. Conclusion Our series compared similarly with the few reports available in the literature. However, a striking finding noted by the authors was a drop in the incidence of tibial shaft football fractures. It is likely that this is a reflection of recent compulsory FIFA regulations on shinguards as well as improvements in the design over the past decade since its introduction. PMID:17567522

  5. Minimally invasive plating osteosynthesis for mid-distal third humeral shaft fractures.

    PubMed

    Lian, Kejian; Wang, Lei; Lin, Dasheng; Chen, Zhiwen

    2013-08-01

    Mid-distal third humeral shaft fractures can be effectively treated with minimally invasive plating osteosynthesis and intramedullary nailing (IMN). However, these 2 treatments have not been adequately compared. Forty-seven patients (47 fractures) with mid-distal third humeral shaft fractures were randomly allocated to undergo either minimally invasive plating osteosynthesis (n=24) or IMN (n=23). The 2 groups were similar in terms of fracture patterns, fracture location, age, and associated injuries. Intraoperative measurements included blood loss and operative time. Clinical outcome measurements included fracture healing, radial nerve recovery, and elbow and shoulder discomfort. Radiographic measurements included fracture alignment, time to healing, delayed union, and nonunion. Functional outcome was satisfactory in both groups. Mean American Shoulder and Elbow Surgeons score and Mayo score were both better for the minimally invasive plating osteosynthesis group than for the IMN group (98.2 vs 97.6, respectively, and 93.5 vs 94.1, respectively; P<.001). Operative time was shorter and less intraoperative blood loss occurred in the minimally invasive plating osteosynthesis group than in the IMN group. Average time to union was similar in both groups. Primary union was achieved in 23 of 24 patients in the minimally invasive plating osteosynthesis group and in 22 of 23 in the IMN group. Minimally invasive plating osteosynthesis may have outcomes comparable with IMN for the management of mid-distal third humeral shaft fractures. Minimally invasive plating osteosynthesis is more suitable for complex fractures, especially for radial protection and motion recovery of adjacent joints, compared with IMN for simple fractures. Copyright 2013, SLACK Incorporated.

  6. Prediction of incident hip fracture by femoral neck bone mineral density and neck-shaft angle: a 5-year longitudinal study in post-menopausal females.

    PubMed

    Gnudi, S; Sitta, E; Pignotti, E

    2012-08-01

    To compare hip fracture incidence in post-menopausal females who were differently stratified for the fracture risk according to bone mineral density and proximal femur geometry. In a 5 year follow-up study, the hip fracture incidence in 729 post-menopausal females (45 of whom suffered from incident hip fracture) was assessed and compared. Forward logistic regression was used to select independent predictors of hip fracture risk, including age, age at menopause, height, weight, femoral neck bone mineral density (FNBMD), neck-shaft angle (NSA), hip axis length, femoral neck diameter and femoral shaft diameter as covariates. Fracture incidence was then calculated for the categories of young/old age, high/low FNBMD and wide/narrow NSA, which were obtained by dichotomising each hip fracture independent predictor at the value best separating females with and without a hip fracture. The hip fracture incidence of the whole cohort was significantly higher in females with a wide NSA (8.52%) than in those with a narrow NSA (3.51%). The combination of wide NSA and low FNBMD had the highest hip fracture incidence in the whole cohort (17.61%) and each age category. The combinations of narrow/wide NSA with low/high FNBMD, respectively, gave a significantly higher fracture incidence in older than in younger women, whereas women with a combined wide NSA and low FNBMD had no significantly different fracture incidence in young (14.60%) or old age (21.62%). Our study showed that NSA is effective at predicting the hip fracture risk and that the detection in early post-menopause of a wide NSA together with a low FNBMD should identify females at high probability of incident hip fracture.

  7. Reverse distal femoral locking compression plate a salvage option in nonunion of proximal femoral fractures.

    PubMed

    Dumbre Patil, Sampat S; Karkamkar, Sachin S; Patil, Vaishali S Dumbre; Patil, Shailesh S; Ranaware, Abhijeet S

    2016-01-01

    When primary fixation of proximal femoral fractures with implants fails, revision osteosynthesis may be challenging. Tracts of previous implants and remaining insufficient bone stock in the proximal femur pose unique problems for the treatment. Intramedullary implants like proximal femoral nail (PFN) or surface implants like Dynamic Condylar Screw (DCS) are few of the described implants for revision surgery. There is no evidence in the literature to choose one implant over the other. We used the reverse distal femur locking compression plate (LCP) of the contralateral side in such cases undergoing revision surgery. This implant has multiple options of fixation in proximal femur and its curvature along the length matches the anterior bow of the femur. We aimed to evaluate the efficacy of this implant in salvage situations. Twenty patients of failed primary proximal femoral fractures who underwent revision surgery with reverse distal femoral locking plate from February 2009 to November 2012 were included in this retrospective study. There were 18 subtrochanteric fractures and two ipsilateral femoral neck and shaft fractures, which exhibited delayed union or nonunion. The study included 14 males and six females. The mean patient age was 43.6 years (range 22-65 years) and mean followup period was 52.1 months (range 27-72 months). Delayed union was considered when clinical and radiological signs of union failed to progress at the end of four months from initial surgery. All fractures exhibited union without any complications. Union was assessed clinically and radiologically. One case of ipsilateral femoral neck and shaft fracture required bone grafting at the second stage for delayed union of the femoral shaft fracture. Reverse distal femoral LCP of the contralateral side can be used as a salvage option for failed fixation of proximal femoral fractures exhibiting nonunion.

  8. Intramedullary nailing of humeral shaft fractures.

    PubMed

    Pickering, Robert M; Crenshaw, Andrew H; Zinar, Daniel M

    2002-01-01

    The development of interlocking humeral nail systems has greatly broadened the indications for nailing of humeral shaft fracture. Rotational control is better than with earlier nail systems, and most nails have an oblong distal hole that allows axial loading of the fracture site with muscle contraction. When nailing is done with closed technique, loss of the fracture hematoma and periosteal stripping are avoided. Even when open reduction is required, periosteal stripping can be kept to a minimum. Surgical wounds are smaller, even when open reduction is necessary, and when closed nailing is done, bone grafting is unnecessary. Intramedullary nails are ideal for segmental fractures, pathologic fractures, and fractures in osteopenic bone. Because the arm usually is not a weight-bearing extremity, hardware failure is rare and union rates are equivalent to those of compression plate and screw fixation. Compression plates and external fixation certainly have their place for some fracture patterns and for severe wounds that are unsuitable for intramedullary nailing. The surgeon should be well versed in all three techniques and should be able to rapidly choose among these, depending upon the fracture pattern, skin wound, associated injuries, and overall condition of the patient.

  9. Prediction on fracture risk of femur with Osteogenesis Imperfecta using finite element models: Preliminary study

    NASA Astrophysics Data System (ADS)

    Wanna, S. B. C.; Basaruddin, K. S.; Mat Som, M. H.; Mohamad Hashim, M. S.; Daud, R.; Majid, M. S. Abdul; Sulaiman, A. R.

    2017-10-01

    Osteogenesis imperfecta (OI) is a genetic disease which affecting the bone geometry. In a severe case, this disease can cause death to patients. The main issue of this disease is the prediction on bone fracture by the orthopaedic surgeons. The resistance of the bone to withstand the force before the bones fracture often become the main concern. Therefore, the objective of the present preliminary study was to investigate the fracture risk associated with OI bone, particularly in femur, when subjected to the self-weight. Finite element (FEA) was employed to reconstruct the OI bone model and analyse the mechanical stress response of femur before it fractures. Ten deformed models with different severity of OI bones were developed and the force that represents patient self-weight was applied to the reconstructed models in static analysis. Stress and fracture risk were observed and analysed throughout the simulation. None of the deformed model were observed experienced fracture. The fracture risk increased with increased severity of the deformed bone. The results showed that all deformed femur models were able to bear the force without experienced fracture when subjected to only the self-weight.

  10. Pediatric Diaphyseal Femur Fractures: Submuscular Plating Compared With Intramedullary Nailing.

    PubMed

    Sutphen, Sean A; Mendoza, Juan D; Mundy, Andrew C; Yang, Jingzhen G; Beebe, Allan C; Samora, Walter P; Klingele, Kevin E

    2016-11-01

    This study compared the radiographic and clinical outcomes of pediatric diaphyseal femur fractures treated by submuscular plating, flexible retrograde intramedullary nailing, or rigid antegrade intramedullary nailing with a trochanteric entry point in skeletally immature patients who were 8 years and older. A retrospective review was conducted of skeletally immature patients 8 years and older who were treated for femur fracture with submuscular plating, flexible intramedullary nailing, or rigid intramedullary nailing from 2001 to 2014 with a minimum 12-week follow-up. Treatment outcomes were compared for statistical significance, including time to union, malunion, nonunion, heterotopic ossification, avascular necrosis, time to full weight bearing, limb length discrepancy, residual limp, painful hardware, and infection. The study identified 198 femur fractures in 196 patients (mean age, 11.9 years). Each femur fracture was treated with submuscular plating (35), flexible intramedullary nailing (61), or rigid intramedullary nailing (102). Mean follow-up across the cohort was 48 weeks, ranging from 12 to 225 weeks. Flexible nailing was associated with an increased incidence of malunion (P<.0001) and hardware irritation (P=.0204) and longer time to full weight bearing (P=.0018). Rigid nailing was associated with an increased incidence of limp at 12-week followup (P=.0412). Additionally, 23.5% of patients who were treated with rigid nailing had heterotopic ossification. Of all surgical methods, submuscular plating allowed for the most rapid return to full weight bearing (mean, 7 weeks) and offered the fastest healing rate (mean, 6 weeks). Submuscular plating resulted in faster times to union and full weight bearing, with minimal complication rates. Rigid intramedullary nailing with trochanteric entry resulted in a lower incidence of malunion and hardware-related complications; however, these patients had an increased incidence of heterotopic ossification and residual

  11. Effectiveness of a Model Bundle Payment Initiative for Femur Fracture Patients.

    PubMed

    Lott, Ariana; Belayneh, Rebekah; Haglin, Jack; Konda, Sanjit; Egol, Kenneth A

    2018-05-28

    Analyze the effectiveness of a BPCI (Bundle Payments for Care Improvement) initiative for patients who would be included in a future potential Surgical Hip and Femur Fracture Treatment (SHFFT) bundle. Retrospective cohort SETTING:: Single Academic Institution PATIENTS/PARTICIPANTS:: Patients discharged with operative fixation of a hip or femur fracture (DRG codes 480-482) between 1/2015-10/2016 were included. A BPCI initiative based upon an established program for BPCI Total Joint Arthroplasty (TJA) was initiated for patients with hip and femur fractures in January 2016. Patients were divided into non-bundle (care before initiative) and bundle (care with initiative) cohorts. Application of BPCI principles MAIN OUTCOME MEASURES:: Length of stay, location of discharge, readmissions RESULTS:: 116 patients participated in the "institutional bundle," and 126 received care prior to the initiative. There was a trend towards decreased mean length of stay, (7.3 ± 6.3 days vs. 6.8 ± 4.0 days, p=0.457) and decreased readmission within 90 days (22.2% vs. 18.1%, p=0.426). The number of patients discharged home doubled (30.2% vs. 14.3%, p=0.008). There was no difference in readmission rates in bundle vs. non-bundle patients based on discharged home status; however, bundle patients discharged to SNF trended towards less readmissions than non-bundle patients discharged to SNF (37.3% vs. 50.6%, p=0.402). Mean episode cost reduction due to initiative was estimated to be $6,450 using Medicare reimbursement data. This study demonstrates the potential success of a BPCI initiative at one institution in decreasing post-acute care facility utilization and cost of care when used for a hip and femur fracture population. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  12. Biomechanical characterisation of osteosyntheses for proximal femur fractures: helical blade versus screw.

    PubMed

    Al-Munajjed, Amir A; Hammer, Joachim; Mayr, Edgar; Nerlich, Michael; Lenich, Andreas

    2008-01-01

    Proximal femur fractures are of main concern for elderly and especially osteoporotic patients. Despite advanced implant modifications and surgical techniques, serious mechanical complication rates between 4-18% are found in conventional osteosyntheses of proximal femur fractures. Clinical complications such as the rotation of the femoral head and the cut-out phenomenon of the fracture fixation bolt are often diagnosed during post-operative treatments. Therefore, efforts in new intramedulary techniques focus on the load bearing characteristics of the implant by developing new geometries to improve the implant-tissue interface. The objective of this investigation was to analyse the osteosynthesis/femur head interaction of two commonly used osteosyntheses, one with a helical blade and the other one with a screw design under different loading conditions. For the comparative investigation the helical blade of the Proximal Femur Nail Antirotation was investigated versus the screw system of the Dynamic Hip Screw. After implantation in a femoral head the loads for rotational overwinding of the implants were analysed. Pull-out forces with suppressed rotation were investigated with analysis of the influence of the previous overwinding. All investigations were performed on human femoral heads taken of patients with average age of 70.3+/-11.8. The bone mineral densities of the human specimens were detected by QCT-scans (average BMD: 338.9+/- 61.3$\\frac[\\mathit[mg

  13. Management of Open Tibial Shaft Fractures: Does the Timing of Surgery Affect Outcomes?

    PubMed

    Duyos, Oscar A; Beaton-Comulada, David; Davila-Parrilla, Ariel; Perez-Lopez, Jose Carlos; Ortiz, Krystal; Foy-Parrilla, Christian; Lopez-Gonzalez, Francisco

    2017-03-01

    Open tibial shaft fractures require emergent care. Treatment with intravenous antibiotics and fracture débridement within 6 to 24 hours is recommended. Few studies have examined outcomes when surgical treatment is performed >24 hours after occurrence of the fracture. This retrospective study included 227 patients aged ≥18 years with isolated open tibial shaft fractures in whom the time to initial débridement was >24 hours. The statistical analysis was based on time from injury to surgical débridement, Gustilo-Anderson classification, method of fixation, union status, and infection status. Fractures débrided within 24 to 48 hours and 48 to 96 hours after injury did not show a statistically significant difference in terms of infection rates (P = 0.984). External fixation showed significantly greater infection rates (P = 0.044) and nonunion rates (P = 0.001) compared with intramedullary nailing. Open tibial shaft fractures should be débrided within 24 hours after injury. Our data indicate that after the 24-hour period and up to 4 days, the risk of infection remains relatively constant independent of the time to débridement. Patients treated with external fixation had more complications than did patients treated with other methods of fixation. Primary reamed intramedullary nailing appears to be a reasonable option for the management of Gustilo-Anderson types 1 and 2 open tibial shaft fractures. Level III retrospective study.

  14. Development of a fixation device for robot assisted fracture reduction of femoral shaft fractures: a biomechanical study.

    PubMed

    Weber-Spickschen, T S; Oszwald, M; Westphal, R; Krettek, C; Wahl, F; Gosling, T

    2010-01-01

    Robot assisted fracture reduction of femoral shaft fractures provides precise alignment while reducing the amount of intraoperative imaging. The connection between the robot and the fracture fragment should allow conventional intramedullary nailing, be minimally invasive and provide interim fracture stability. In our study we tested three different reduction tools: a conventional External Fixator, a Reposition-Plate and a Three-Point-Device with two variations (a 40 degrees and a 90 degrees version). We measured relative movements between the tools and the bone fragments in all translation and rotation planes. The Three-Point-Device 90 degrees showed the smallest average relative displacement and was the only device able to withstand the maximum applied load of 70 Nm without failure of any bone fragment. The Three-Point-Device 90 degrees complies with all the stipulated requirements and is a suitable interface for robot assisted fracture reduction of femoral shaft fractures.

  15. Atypical femur fractures: a review of the evidence and its implication to clinical practice

    PubMed Central

    Girgis, Christian M.

    2011-01-01

    Whilst bisphosphonates are an established modality in the treatment of osteoporosis, there have been increasing concerns regarding the risk of an unusual form of femur fracture amongst patients receiving bisphosphonates for prolonged periods. These fractures, referred to as ‘atypical’, have been characterized by a number of clinical and radiographic features that distinguish them from ‘typical’ osteoporotic fractures. The evidence base is currently split between a large number of case series demonstrating an association between the occurrence of atypical fractures and bisphosphonate use and several population-based studies that do not confirm such an association. Hence, a degree of uncertainty surrounds this important issue. In this review, we examine the emerging evidence on atypical femur fractures, assess hypotheses on their biomechanical evolution and discuss the wider clinical implications of this phenomenon. PMID:22870488

  16. Prediction of incident hip fracture by femoral neck bone mineral density and neck–shaft angle: a 5-year longitudinal study in post-menopausal females

    PubMed Central

    Gnudi, S; Sitta, E; Pignotti, E

    2012-01-01

    Objective To compare hip fracture incidence in post-menopausal females who were differently stratified for the fracture risk according to bone mineral density and proximal femur geometry. Methods In a 5 year follow-up study, the hip fracture incidence in 729 post-menopausal females (45 of whom suffered from incident hip fracture) was assessed and compared. Forward logistic regression was used to select independent predictors of hip fracture risk, including age, age at menopause, height, weight, femoral neck bone mineral density (FNBMD), neck–shaft angle (NSA), hip axis length, femoral neck diameter and femoral shaft diameter as covariates. Fracture incidence was then calculated for the categories of young/old age, high/low FNBMD and wide/narrow NSA, which were obtained by dichotomising each hip fracture independent predictor at the value best separating females with and without a hip fracture. Results The hip fracture incidence of the whole cohort was significantly higher in females with a wide NSA (8.52%) than in those with a narrow NSA (3.51%). The combination of wide NSA and low FNBMD had the highest hip fracture incidence in the whole cohort (17.61%) and each age category. The combinations of narrow/wide NSA with low/high FNBMD, respectively, gave a significantly higher fracture incidence in older than in younger women, whereas women with a combined wide NSA and low FNBMD had no significantly different fracture incidence in young (14.60%) or old age (21.62%). Conclusion Our study showed that NSA is effective at predicting the hip fracture risk and that the detection in early post-menopause of a wide NSA together with a low FNBMD should identify females at high probability of incident hip fracture. PMID:22096224

  17. The Tribology of Explanted Hip Resurfacings Following Early Fracture of the Femur.

    PubMed

    Lord, James K; Langton, David J; Nargol, Antoni V F; Meek, R M Dominic; Joyce, Thomas J

    2015-10-15

    A recognized issue related to metal-on-metal hip resurfacings is early fracture of the femur. Most theories regarding the cause of fracture relate to clinical factors but an engineering analysis of failed hip resurfacings has not previously been reported. The objective of this work was to determine the wear volumes and surface roughness values of a cohort of retrieved hip resurfacings which were removed due to early femoral fracture, infection and avascular necrosis (AVN). Nine resurfacing femoral heads were obtained following early fracture of the femur, a further five were retrieved due to infection and AVN. All fourteen were measured for volumetric wear using a co-ordinate measuring machine. Wear rates were then calculated and regions of the articulating surface were divided into "worn" and "unworn". Roughness values in these regions were measured using a non-contacting profilometer. The mean time to fracture was 3.7 months compared with 44.4 months for retrieval due to infection and AVN. Average wear rates in the early fracture heads were 64 times greater than those in the infection and AVN retrievals. Given the high wear rates of the early fracture components, such wear may be linked to an increased risk of femoral neck fracture.

  18. Systematic review of spica casting for the treatment of paediatric diaphyseal femur fractures

    PubMed Central

    Tisherman, R. T.; Hoellwarth, J. S.; Mendelson, S. A.

    2018-01-01

    Purpose Paediatric femur fractures are commonly encountered and often successfully managed with spica casting. Despite spica casting’s long history there is little formal guidance for optimal outcomes and no consolidation of existing literature. The purpose of this study is to review the available literature regarding the use of spica casting for the management of paediatric diaphyseal femur fractures. Methods The PubMed database was queried for all research articles including the phrase “spica”. A total of 788 abstracts were reviewed for relevance to the current study. Data was extracted from all available research studies which specified tolerance for fracture angulation or shortening in the cast. Additionally, all articles describing alternative materials, methods for spica application, and complications of spica casting were reviewed. Results In all, 106 articles were found relevant to the management of diaphyseal femur fractures in the paediatric population. The aggregated, accepted fracture shortening decreased from 16 mm to 18 mm before age ten years to 12 mm to 14 mm after puberty. Aggregated, accepted angulation decreased from 14° to 16° varus/valgus and 18° to 22° pro/recurvatum before age two years, to 6° to 8° and 10° to 12° by puberty, respectively. The overall reported complication rate was 19.6%, with the most common complication being skin compromise in 8.2% of patients, followed by unacceptable angulation at the fracture site in 4.2% of patients and excessive limb shortening in 1.9% of patients. Conclusion This article reviews the available spica casting literature and compiles the available data. Spica casting offers a safe, effective means for definitive management of paediatric diaphyseal femur fractures. Future research identifying the rate and pattern of remodelling as it relates to angulation and shortening at various patient ages, particularly beyond the aforementioned norms, would be valuable to identify true biological

  19. Systematic review of spica casting for the treatment of paediatric diaphyseal femur fractures.

    PubMed

    Tisherman, R T; Hoellwarth, J S; Mendelson, S A

    2018-04-01

    Paediatric femur fractures are commonly encountered and often successfully managed with spica casting. Despite spica casting's long history there is little formal guidance for optimal outcomes and no consolidation of existing literature. The purpose of this study is to review the available literature regarding the use of spica casting for the management of paediatric diaphyseal femur fractures. The PubMed database was queried for all research articles including the phrase "spica". A total of 788 abstracts were reviewed for relevance to the current study. Data was extracted from all available research studies which specified tolerance for fracture angulation or shortening in the cast. Additionally, all articles describing alternative materials, methods for spica application, and complications of spica casting were reviewed. In all, 106 articles were found relevant to the management of diaphyseal femur fractures in the paediatric population. The aggregated, accepted fracture shortening decreased from 16 mm to 18 mm before age ten years to 12 mm to 14 mm after puberty. Aggregated, accepted angulation decreased from 14° to 16° varus/valgus and 18° to 22° pro/recurvatum before age two years, to 6° to 8° and 10° to 12° by puberty, respectively. The overall reported complication rate was 19.6%, with the most common complication being skin compromise in 8.2% of patients, followed by unacceptable angulation at the fracture site in 4.2% of patients and excessive limb shortening in 1.9% of patients. This article reviews the available spica casting literature and compiles the available data. Spica casting offers a safe, effective means for definitive management of paediatric diaphyseal femur fractures. Future research identifying the rate and pattern of remodelling as it relates to angulation and shortening at various patient ages, particularly beyond the aforementioned norms, would be valuable to identify true biological tolerances versus accepted expert opinion

  20. [Incidence of proximal femur fractures in relation to seasons of the year and weather].

    PubMed

    Burget, F; Pleva, L; Kudrna, K; Kudrnová, Z

    2012-01-01

    The opinion that proximal femur fractures occur mainly in the winter season and are related to slippery surfaces prevails in both the lay and medical communities. The elucidation of this relationship would lead to a better understanding of the aetiology of these fractures and may help to prevent them in the elderly population. In a retrospective study conducted at two departments, the occurrence of proximal femur fractures in patients 60+ years old in relation to weather conditions (air temperature and its humidity, atmospheric pressure, rain and mist) between January 1, 2001 and December 31, 2005 was investigated. Patients with high-energy or pathological fractures were excluded. The results were evaluated by Statistika software. A total of 1720 patients were studied, of whom 1313 were women and 407 were men. The numbers of fractures did not differ significantly among either the seasons or months of the year. No correlation was found between the number of fractures and each of the weather characteristics (air temperature and its humidity, atmospheric pressure, wind speed and visibility). It is widely believed that hip fractures are connected with winter months and temperatures below zero. This is supported by several facts related to winter characteristics, such as slippery icy pavements, clumsiness due to warm bulky clothes, bodies affected by cold and thus predisposed to a fall and poorer visibility on shorter winter days. The effect of seasonal variation on hip fracture incidence has been investigated in 10 studies of which only one has taken the influence of daily temperature into consideration. All studies were conduced in the countries north of 40° latitude, i.e., in climatic conditions similar to our country, with temperatures falling below zero and ice-glazed pavements in winter months. Of them, six have found no relation between proximal femur fractures and weather conditions, two have reported an increased incidence of these fractures in winter months

  1. Basic principles of fracture treatment in children.

    PubMed

    Ömeroğlu, Hakan

    2018-04-01

    This review aims to summarize the basic treatment principles of fractures according to their types and general management principles of special conditions including physeal fractures, multiple fractures, open fractures, and pathologic fractures in children. Definition of the fracture is needed for better understanding the injury mechanism, planning a proper treatment strategy, and estimating the prognosis. As the healing process is less complicated, remodeling capacity is higher and non-union is rare, the fractures in children are commonly treated by non-surgical methods. Surgical treatment is preferred in children with multiple injuries, in open fractures, in some pathologic fractures, in fractures with coexisting vascular injuries, in fractures which have a history of failed initial conservative treatment and in fractures in which the conservative treatment has no/little value such as femur neck fractures, some physeal fractures, displaced extension and flexion type humerus supracondylar fractures, displaced humerus lateral condyle fractures, femur, tibia and forearm shaft fractures in older children and adolescents and unstable pelvis and acetabulum fractures. Most of the fractures in children can successfully be treated by non-surgical methods.

  2. A tumor endoprosthesis is useful in elderly rheumatoid arthritis patient with acute intercondylar fracture of the distal femur.

    PubMed

    Wakabayashi, Hiroki; Naito, Yohei; Hasegawa, Masahiro; Nakamura, Tomoki; Sudo, Akihiro

    2012-05-01

    The purpose of this paper is to report the use of total knee arthroplasty using a tumor prosthesis in the treatment of elderly patients with an intercondylar fracture of the distal femur. Supracondylar fractures of the femur in patients with rheumatoid arthritis are difficult to treat due to joint deformity. We present outcomes for treating intercondylar fractures of the distal femur in rheumatoid arthritis patient using a tumor endoprosthesis. This technique allows early mobilization of the patient, with restoration of a good range of knee motion. A tumor prosthesis appears to be a viable treatment option for intercondylar femoral fractures in elderly patients. It is well tolerated and permits early ambulation and return to activities of daily living.

  3. Bone density of the radius, spine, and proximal femur in osteoporosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mazess, R.B.; Barden, H.; Ettinger, M.

    1988-02-01

    Bone mineral density (BMD) was measured in 140 normal young women (aged 20 to 39 years) and in 423 consecutive women over age 40 referred for evaluation of osteoporosis. Lumbar spine and proximal femur BMD was measured using dual-photon absorptiometry (/sup 153/Gd), whereas the radius shaft measurement used single-photon absorptiometry (/sup 125/I). There were 324 older women with no fractures, of which 278 aged 60 to 80 years served as age-matched controls. There were 99 women with fractures including 32 with vertebral and 22 with hip fractures. Subsequently, another 25 women with hip fractures had BMD measured in another laboratory;more » their mean BMD was within 2% of that of the original series. The mean age in both the nonfracture and fracture groups was 70 +/- 5 years. The BMD in the age-matched controls was 20% to 25% below that of normal young women for the radius, spine, and femur, but the Ward's triangle region of the femur showed even greater loss (35%). The mean BMD at all sites in the crush fracture cases was about 10% to 15% below that of age-matched controls. Spinal abnormality was best discriminated by spine and femoral measurements (Z score about 0.9). In women with hip fractures, the BMD was 10% below that of age-matched controls for the radius and the spine, and the BMD for the femoral sites was about 25% to 30% below that of age-matched control (Z score about 1.6). Femoral densities gave the best discrimination of hip fracture cases and even reflected spinal osteopenia. In contrast, neither the spine nor the radius reflected the full extent of femoral osteopenia in hip fracture.« less

  4. Fat Embolism Syndrome After Femur Fracture Fixation: a Case Report

    PubMed Central

    Akoh, Craig C; Schick, Cameron; Otero, Jesse; Karam, Matthew

    2014-01-01

    Fat embolism syndrome (FES) is a multi-organ disorder with potentially serious sequelae that is commonly seen in the orthopaedic patient population after femur fractures. The major clinical features of FES include hypoxia, pulmonary dysfunction, mental status changes, petechiae, tachycardia, fever, thrombocytopenia, and anemia. Due to technological advances in supportive care and intramedullary reaming techniques, the incidence of FES has been reported as low as 0.5 percent. Here, we present a rare case of FES with cerebral manifestations. A previously healthy 24-year old nonsmoking male was admitted to our hospital after an unrestrained head-on motor vehicle collision. The patient's injuries included a left olecranon fracture and closed bilateral comminuted midshaft femur fractures. The patient went on to develop cerebral fat embolism syndrome (CFES) twelve hours after immediate bilateral intramedullary nail fixation. His symptoms included unresponsiveness, disconjugate gaze, seizures, respiratory distress, fever, anemia, thrombocytopenia, and visual changes. Head computed tomography and brain magnetic resonance imaging showed pathognomonic white-matter punctate lesions and watershed involvement. With early recognition and supportive therapy and seizure therapy, the patient went on to have complete resolution of symptoms without cognitive sequelae. PMID:25328460

  5. Long-term functional outcome following intramedullary nailing of femoral shaft fractures.

    PubMed

    el Moumni, Mostafa; Voogd, Emma Heather; ten Duis, Henk Jan; Wendt, Klaus Wilhelm

    2012-07-01

    The management of femoral shaft fractures using intramedullary nailing is a popular method. The purpose of this study was to evaluate the long-term functional outcome after antegrade or retrograde intramedullary nailing of traumatic femoral shaft fractures. We further determined predictors of these functional outcome scores. In a retrospective study, patients with a femoral shaft fracture but no other injuries to the lower limbs or pelvis were included. A total of 59 patients met the inclusion criteria. Functional outcome scores (Short Musculoskeletal Functional Assessment (SMFA), Western Ontario and McMaster University Osteoarthritis (WOMAC) index, Harris Hip Score (HHS) and the Lysholm knee function scoring scale) were measured at a mean of 7.8 years (± 3.5 years) postoperatively. The Visual Analogue Scale (VAS) was used to determine pain complaints of the lower limb. The range of motion (ROM) of the hip and knee joints was comparable between the injured and uninjured leg, regardless of the nailing technique. Correlation between ROM and the final outcome scores was found to be fair to moderate. Even years after surgery, 17% of the patients still reported moderate to severe pain. A substantial correlation was observed between VAS and the patient-reported outcome scores. The most significant predictor of functional outcome was pain in the lower limb. Our findings suggest that the ROM of hip and knee returns to normal over time, regardless of the nailing method used. However, pain in the lower limb is an important predictor and source of disability after femoral shaft fractures, even though most patients achieved good functional outcome scores. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. Comminuted distal femur closed fractures: a new application of the Ilizarov concept of compression-distraction.

    PubMed

    El-Tantawy, Ahmad; Atef, Ashraf

    2015-04-01

    The treatment of intra-articular distal femur fractures with severe metaphyseal comminution is challenging. It is important to choose a technique that provides secure fixation, minimum tissue handling, and early ambulation. The aim of this work was to evaluate the outcomes of application of Ilizarov concept as an early definitive treatment of comminuted distal femur closed fractures. A total of 17 male patients (mean age 28.53±6.33 years) presented with comminuted distal femur fractures (with 10 type C2 and 7 type C3-2 fractures according to AO/ASIF system) were included in this prospective study. Initial fixation of the articular fragments was done by inter-fragmentary screws, percutaneously through a limited open approach, and stabilization was completed by Ilizarov fixator. The procedure included acute shortening, through the comminution, followed by gradual re-distraction to compensate the created shortening. Radiological and functional results were assessed according to ASAMI evaluation system. The mean amount of intra-operative shortening was 3.68±0.53 cm. The mean external fixation index was 37.24±2.53 days/cm. The mean follow-up period was 18.18±1.91 months. All fractures united primarily in an average 137.65±4.12 days, with no evident angular deformity or limb-length discrepancy. None of the cases required a second major procedure or bone graft. The functional results were excellent in three cases, good in 12, and fair in two patients. The Ilizarov concept of acute compression-distraction is a valuable alternative for the treatment of distal femur fractures with severe metaphyseal comminution.

  7. Biomechanical assessment of composite versus metallic intramedullary nailing system in femoral shaft fractures: A finite element study.

    PubMed

    Samiezadeh, Saeid; Tavakkoli Avval, Pouria; Fawaz, Zouheir; Bougherara, Habiba

    2014-08-01

    Intramedullary nails are the primary choice for treating long bone fractures. However, complications following nail surgery including non-union, delayed union, and fracture of the bone or the implant still exist. Reducing nail stiffness while still maintaining sufficient stability seems to be the ideal solution to overcome the abovementioned complications. In this study, a new hybrid concept for nails made of carbon fibers/flax/epoxy was developed in order to reduce stress shielding. The mechanical performance of this new implant in terms of fracture stability and load sharing was assessed using a comprehensive non-linear FE model. This model considers several mechanical factors in nine fracture configurations at immediately post-operative, and in the healed bone stages. Post-operative results showed that the hybrid composite nail increases the average normal force at the fracture site by 319.23N (P<0.05), and the mean stress in the vicinity of fracture by 2.11MPa (P<0.05) at 45% gait cycle, while only 0.33mm and 0.39mm (P<0.05) increases in the fracture opening and the fragments' shear movement were observed. The healed bone results revealed that implantation of the titanium nail caused 20.2% reduction in bone stiffness, while the composite nail lowered the stiffness by 11.8% as compared to an intact femur. Our results suggest that the composite nail can provide a preferred mechanical environment for healing, particularly in transverse shaft fractures. This may help bioengineers better understand the biomechanics of fracture healing, and aid in the design of effective implants. Copyright © 2014. Published by Elsevier Ltd.

  8. Rereduction for Redisplacement of Both-Bone Forearm Shaft Fractures in Children.

    PubMed

    Eismann, Emily A; Parikh, Shital N; Jain, Viral V

    2016-06-01

    There is a high rate of redisplacement after closed reduction and cast treatment of displaced both-bone forearm shaft fractures in children. Little evidence is available on the efficacy of rereduction of these redisplaced fractures. This study evaluates the impact of rereduction on radiographic outcomes and compares the cost to surgical stabilization. This retrospective study included 31 children (mean age, 6.3 y; 18 boys) treated with rereduction for redisplacement of a displaced both-bone forearm shaft fracture between 2008 and 2013. Angulation was measured on anteroposterior and lateral radiographs of the radius and ulna at injury, after reduction, at redisplacement, after rereduction, and at fracture union. Average procedure costs for rereduction and surgical stabilization were calculated. Initial reduction decreased apex volar angulation (initially >20 degrees) of both bones to a median of ≤2 degrees. After an average of 15 days (range, 4 to 35 d), apex volar angulation of the radius worsened to 9 degrees, and apex ulnar angulation worsened to >10 degrees for both bones. For every 5 days after initial reduction, apex ulnar angulation of the radius worsened by 4 degrees. Rereduction reduced apex ulnar and volar angulation of both bones to <5 degrees, which was maintained after cast removal. There were no complications. The average procedure cost for rereduction was $2056 compared with $4589 for surgical stabilization with or without implant removal. Rereduction of both-bone forearm shaft fractures after redisplacement following initial closed reduction had satisfactory radiographic outcomes and is a safe, effective, and less expensive option than surgical stabilization. Level IV-therapeutic.

  9. Implant Augmentation: Adding Bone Cement to Improve the Treatment of Osteoporotic Distal Femur Fractures

    PubMed Central

    Wähnert, Dirk; Hofmann-Fliri, Ladina; Richards, R. Geoff; Gueorguiev, Boyko; Raschke, Michael J.; Windolf, Markus

    2014-01-01

    Abstract The increasing problems in the field of osteoporotic fracture fixation results in specialized implants as well as new operation methods, for example, implant augmentation with bone cement. The aim of this study was to determine the biomechanical impact of augmentation in the treatment of osteoporotic distal femur fractures. Seven pairs of osteoporotic fresh frozen distal femora were randomly assigned to either an augmented or nonaugmented group. In both groups, an Orthopaedic Trauma Association 33 A3 fractures was fixed using the locking compression plate distal femur and cannulated and perforated screws. In the augmented group, additionally, 1 mL of polymethylmethacrylate cement was injected through the screw. Prior to mechanical testing, bone mineral density (BMD) and local bone strength were determined. Mechanical testing was performed by cyclic axial loading (100 N to 750 N + 0.05N/cycle) using a servo-hydraulic testing machine. As a result, the BMD as well as the axial stiffness did not significantly differ between the groups. The number of cycles to failure was significantly higher in the augmented group with the BMD as a significant covariate. In conclusion, cement augmentation can significantly improve implant anchorage in plating of osteoporotic distal femur fractures. PMID:25415673

  10. Numerical Modelling of Femur Fracture and Experimental Validation Using Bone Simulant.

    PubMed

    Marco, Miguel; Giner, Eugenio; Larraínzar-Garijo, Ricardo; Caeiro, José Ramón; Miguélez, María Henar

    2017-10-01

    Bone fracture pattern prediction is still a challenge and an active field of research. The main goal of this article is to present a combined methodology (experimental and numerical) for femur fracture onset analysis. Experimental work includes the characterization of the mechanical properties and fracture testing on a bone simulant. The numerical work focuses on the development of a model whose material properties are provided by the characterization tests. The fracture location and the early stages of the crack propagation are modelled using the extended finite element method and the model is validated by fracture tests developed in the experimental work. It is shown that the accuracy of the numerical results strongly depends on a proper bone behaviour characterization.

  11. EPIDEMIOLOGY OF FEMUR FRACTURES IN THE ELDERLY AND COST TO THE STATE OF PARANÁ, BRAZIL.

    PubMed

    Oliveira, Camila Cristine; Borba, Victoria Zeghbi Cochenski

    2017-01-01

    To evaluate the incidence and economic impact of femur fractures in the state of Paraná, Brazil . This descriptive study included men and women ≥ 60 years of age with hip fractures which were treated by the Public Health System in emergency care from January 2010 to December 2014. Data were collected from the DATASUS public health database using filters to select patients; results were presented descriptively and as proportions. The standardized incidence of femur fracture was calculated by sex and age for 10,000 inhabitants in Paraná state and in Brazil for the year 2012 . During the study period, 11,226 fractures were registered, 66.8% in women and 33.2% in men. There was a preponderance of fractures in Caucasians and in older age groups. Mortality during hospitalization was 5.9%, higher in males, in patients aged ≥80 years, and in Blacks and Asians. The total cost was R$ 29,393,442.78 and the average cost per hospitalization was R$ 2,618.34. The eastern region of the state had the highest rate of fractures, predominantly in the capital, Curitiba. The standardized incidence rate was higher in females and in the population of Paraná . Femur fractures have a high incidence rate in the elderly population of Paraná and a large economic impact. Level of Evidence II, Prognostic Studies Investigating the effect of a Patient Characterisctic on the Outcome of Disease.

  12. EPIDEMIOLOGY OF FEMUR FRACTURES IN THE ELDERLY AND COST TO THE STATE OF PARANÁ, BRAZIL

    PubMed Central

    Oliveira, Camila Cristine; Borba, Victoria Zeghbi Cochenski

    2017-01-01

    ABSTRACT Objectives: To evaluate the incidence and economic impact of femur fractures in the state of Paraná, Brazil . Methods: This descriptive study included men and women ≥ 60 years of age with hip fractures which were treated by the Public Health System in emergency care from January 2010 to December 2014. Data were collected from the DATASUS public health database using filters to select patients; results were presented descriptively and as proportions. The standardized incidence of femur fracture was calculated by sex and age for 10,000 inhabitants in Paraná state and in Brazil for the year 2012 . Results: During the study period, 11,226 fractures were registered, 66.8% in women and 33.2% in men. There was a preponderance of fractures in Caucasians and in older age groups. Mortality during hospitalization was 5.9%, higher in males, in patients aged ≥80 years, and in Blacks and Asians. The total cost was R$ 29,393,442.78 and the average cost per hospitalization was R$ 2,618.34. The eastern region of the state had the highest rate of fractures, predominantly in the capital, Curitiba. The standardized incidence rate was higher in females and in the population of Paraná . Conclusion: Femur fractures have a high incidence rate in the elderly population of Paraná and a large economic impact. Level of Evidence II, Prognostic Studies Investigating the effect of a Patient Characterisctic on the Outcome of Disease. PMID:28955173

  13. [New anterolateral approach of distal femur for treatment of distal femoral fractures].

    PubMed

    Zhang, Bin; Dai, Min; Zou, Fan; Luo, Song; Li, Binhua; Qiu, Ping; Nie, Tao

    2013-11-01

    To assess the effectiveness of the new anterolateral approach of the distal femur for the treatment of distal femoral fractures. Between July 2007 and December 2009, 58 patients with distal femoral fractures were treated by new anterolateral approach of the distal femur in 28 patients (new approach group) and by conventional approach in 30 patients (conventional approach group). There was no significant difference in gender, age, cause of injury, affected side, type of fracture, disease duration, complication, or preoperative intervention (P > 0.05). The operation time, intraoperative blood loss, intraoperative fluoroscopy frequency, hospitalization days, and Hospital for Special Surgery (HSS) score of knee were recorded. Operation was successfully completed in all patients of 2 groups, and healing of incision by first intention was obtained; no vascular and nerves injuries occurred. The operation time and intraoperative fluoroscopy frequency of new approach group were significantly less than those of conventional approach group (P < 0.05). But the intraoperative blood loss and the hospitalization days showed no significant difference between 2 groups (P > 0.05). All patients were followed up 12-36 months (mean, 19.8 months). Bone union was shown on X-ray films; the fracture healing time was (12.62 +/- 2.34) weeks in the new approach group and was (13.78 +/- 1.94) weeks in the conventional approach group, showing no significant difference (t=2.78, P=0.10). The knee HSS score at last follow-up was 94.4 +/- 4.2 in the new approach group, and was 89.2 +/- 6.0 in the conventional approach group, showing significant difference between 2 groups (t=3.85, P=0.00). New anterolateral approach of the distal femur for distal femoral fractures has the advantages of exposure plenitude, minimal tissue trauma, and early function rehabilitation training so as to enhance the function recovery of knee joint.

  14. Convergence and stress analysis of the homogeneous structure of human femur bone during standing up condition

    NASA Astrophysics Data System (ADS)

    Izzawati, B.; Daud, R.; Afendi, M.; Majid, M. S. Abdul; Zain, N. A. M.

    2017-09-01

    Finite element models have been widely used to quantify the stress analysis and to predict the bone fractures of the human body. The present study highlights on the stress analysis of the homogeneous structure of human femur bone during standing up condition. The main objective of this study is to evaluate and understand the biomechanics for human femur bone and to prepare orthotropic homogeneous material models used for FE analysis of the global proximal femur. Thus, it is necessary to investigate critical stress on the human femur bone for future study on implantation of internal fixator and external fixator. The implication possibility to create a valid FE model by simply comparing the FE results with the actual biomechanics structures. Thus, a convergence test was performed by FE model of the femur and the stress analysis based on the actual biomechanics of the human femur bone. An increment of critical stress shows in the femur shaft as the increasing of load on the femoral head and decreasing the pulling force at greater trochanter.

  15. Design factors of femur fracture fixation plates made of shape memory alloy based on the Taguchi method by finite element analysis.

    PubMed

    Ko, Cheolwoong; Yang, Mikyung; Byun, Taemin; Lee, Sang-Wook

    2018-05-01

    This study proposed a way to design femur fracture fixation plates made of shape memory alloy based on computed tomography (CT) images of Korean cadaveric femurs. To this end, 3 major design factors of femur fracture fixation plates (circumference angle, thickness, and inner diameter) were selected based on the contact pressure when a femur fracture fixation plate was applied to a cylinder model using the Taguchi method. Then, the effects of the design factors were analyzed. It was shown that the design factors were statistically significant at a level of p = 0.05 concerning the inner diameter and the thickness. The factors affecting the contact pressure were inner diameter, thickness, and circumference angle, in that order. Particularly, in the condition of Case 9 (inner diameter 27 mm, thickness 2.4 mm, and circumference angle 270°), the max. average contact pressure was 21.721 MPa, while the min. average contact pressure was 3.118 MPa in Case 10 (inner diameter 29 mm, thickness 2.0 mm, and circumference angle 210°). When the femur fracture fixation plate was applied to the cylinder model, the displacement due to external sliding and pulling forces was analyzed. As a result, the displacement in the sliding condition was at max. 3.75 times greater than that in the pulling condition, which indicated that the cohesion strength between the femur fracture fixation plate and the cylinder model was likely to be greater in the pulling condition. When a human femur model was applied, the max. average contact pressure was 10.76 MPa, which was lower than the yield strength of a human femur (108 MPa). In addition, the analysis of the rib behaviors of the femur fracture fixation plate in relation to the recovery effect of the shape memory alloy showed that the rib behaviors varied depending on the arbitrarily curved shapes of the femur sections. Copyright © 2018 John Wiley & Sons, Ltd.

  16. Lateral Radiograph of the Hip in Fracture Neck of Femur: Is it a Ritual?

    PubMed

    Kumar, Dheerendra S; Gubbi, Shivarathre D; Abdul, Bari; Bisalahalli, Muddu

    2008-10-01

    Historically routine work up of a patient with a fracture neck of femur has always included an antero-posterior (AP) and a lateral view of the hip. The aim of the study was to know whether a lateral view of hip influenced the decision of an Orthopedic Surgeon regarding management at a District General Hospital. A prospective study was conducted from February 2005 to September 2005 at Tameside General Hospital. X-rays of patients admitted with fracture neck of femur were shown to two independent observers in the daily trauma meeting. AP view of the hip was shown initially to observers and their classification and intended treatment was recorded. They were asked if they needed a lateral view to decide on management option and answers were recorded. The observers were then showed a lateral view of same hip and asked to comment on quality of film and also whether it would change their classification or intended management. There were 100 patients over six months. On AP view 56 were classified to have extra-capsular fracture, 37 were classified as displaced subcapital fracture and seven were classified undisplaced subcapital fracture. There was an interobserver variation in one patient between undisplaced or displaced subcapital fracture. The observers felt they would need a lateral X-ray on three occasions and there was a change in classification from undisplaced subcapital to displaced subcapital fracture on first occasion. There was no change in management plan in all the 100 patients after looking at a lateral X-ray. We can conclude that unless required for management a lateral X-ray of hip should be avoided routinely in all patients with fracture neck of femur as it would not only be cost effective but will also reduce radiation exposure to patient and relieve work pressure on radiographers, nursing and portering staff.

  17. "Clothesline technique" for proximal tibial shaft fracture fixation using conventional intramedullary nail: a simple, useful, and inexpensive technique to prevent fracture malalignment.

    PubMed

    Belangero, William Dias; Santos Pires, Robinson Esteves; Livani, Bruno; Rossi, Felipe Lins; de Andrade, Andre Luis Lugnani

    2018-05-01

    Treatment of proximal tibial shaft fractures is always challenging. Despite the development of modern techniques, the literature still shows high complication rates, especially regarding proximal fragment malalignment. It is well known that knee position in flexion during tibial nailing is responsible for extension and valgus deformities of the proximal fragment. Unlike in tibial shaft fractures, nails do not reduce proximal tibial fractures due to the medullary canal width. This study aims to describe a simple, useful, and inexpensive technique to prevent valgus and extension deformities when treating proximal tibial fractures using conventional nails: the so-called clothesline technique.

  18. Outcomes of tibia shaft fractures caused by low energy gunshot wounds.

    PubMed

    Su, Charles A; Nguyen, Mai P; O'Donnell, Jeffrey A; Vallier, Heather A

    2018-05-16

    The purpose of this project was to compare the rates of infections, nonunions, malunions, and secondary operations in tibia fractures resultant from low energy GSWs versus those seen in open and closed tibia fractures resultant from blunt trauma. A secondary objective was to assess the utility of using the traditional Gustilo-Anderson classification system for open fractures to describe fractures secondary to low energy GSW. A retrospective review of 327 patients with tibia shaft fractures was conducted at our level I trauma center. Patients underwent a variety of interventions depending on their injury. Standard fixation techniques were utilized. Outcome measures include: mechanism of injury, rates of superficial and deep infection, nonunion, malunion, and secondary operations. Deep infection after low energy GSW tibia fractures was uncommon and seen in only 2.3% of patients. Rates of infection after low energy GSWs were similar to low and high energy closed tibia fractures resultant from blunt trauma, but significantly less than that seen in open type II (25%, p < 0.05), type IIIA (19.5%, p < 0.05), and type IIIB fractures (47%, p < 0.01). There were no nonunions following GSW fractures, versus 3.7% after closed tibia fractures from blunt trauma (p = 0.2). Nonunions were more common after open fractures from blunt trauma (11%, p < 0.05) versus GSWs. Differences in infection and nonunion were associated with more secondary operations (18%, p < 0.01) in the open tibia fracture group compared with GSWs (2.3%) and closed fractures (7.9% p = 0.19). While GSWs are traditionally thought of as open injuries, low energy GSW tibia fractures had a low rate of infection and no nonunions, and resulted in a reoperation rate similar to closed blunt tibia shaft fractures and significantly lower than open tibia fractures. Copyright © 2018. Published by Elsevier Ltd.

  19. Individual risk factors for deep infection and compromised fracture healing after intramedullary nailing of tibial shaft fractures: a single centre experience of 480 patients.

    PubMed

    Metsemakers, W-J; Handojo, K; Reynders, P; Sermon, A; Vanderschot, P; Nijs, S

    2015-04-01

    Despite modern advances in the treatment of tibial shaft fractures, complications including nonunion, malunion, and infection remain relatively frequent. A better understanding of these injuries and its complications could lead to prevention rather than treatment strategies. A retrospective study was performed to identify risk factors for deep infection and compromised fracture healing after intramedullary nailing (IMN) of tibial shaft fractures. Between January 2000 and January 2012, 480 consecutive patients with 486 tibial shaft fractures were enrolled in the study. Statistical analysis was performed to determine predictors of deep infection and compromised fracture healing. Compromised fracture healing was subdivided in delayed union and nonunion. The following independent variables were selected for analysis: age, sex, smoking, obesity, diabetes, American Society of Anaesthesiologists (ASA) classification, polytrauma, fracture type, open fractures, Gustilo type, primary external fixation (EF), time to nailing (TTN) and reaming. As primary statistical evaluation we performed a univariate analysis, followed by a multiple logistic regression model. Univariate regression analysis revealed similar risk factors for delayed union and nonunion, including fracture type, open fractures and Gustilo type. Factors affecting the occurrence of deep infection in this model were primary EF, a prolonged TTN, open fractures and Gustilo type. Multiple logistic regression analysis revealed polytrauma as the single risk factor for nonunion. With respect to delayed union, no risk factors could be identified. In the same statistical model, deep infection was correlated with primary EF. The purpose of this study was to evaluate risk factors of poor outcome after IMN of tibial shaft fractures. The univariate regression analysis showed that the nature of complications after tibial shaft nailing could be multifactorial. This was not confirmed in a multiple logistic regression model, which

  20. Locked plating of comminuted distal femur fractures: does unlocked screw placement affect stability and failure?

    PubMed

    Cui, Shari; Bledsoe, J G; Israel, Heidi; Watson, J T; Cannada, Lisa K

    2014-02-01

    Locked plates provide greater stiffness, possibly at the expense of fracture healing. The purpose of this study is to evaluate construct stiffness of distal femur plates as a function of unlocked screw position in cadaveric distal femur fractures. Osteoporotic cadaveric femurs were used. Four diaphyseal bridge plate constructs were created using 13-hole distal femur locking plates, all with identical condylar fixation. Constructs included all locked (AL), all unlocked (AUL), proximal unlocked (PUL), and distally unlocked (DUL) groups. Constructs underwent cyclic axial loading with increasing force per interval. Data were gathered on axial stiffness, torsional stiffness, maximum torque required for 5-degree external rotation, and axial force to failure. Twenty-one specimens were divided into AL, AUL, PUL, and DUL groups. Axial stiffness was not significantly different between the constructs. AL and PUL demonstrated greater torsional stiffness, maximum torque, and force to failure than AUL and AL showed greater final torsional stiffness and failure force than DUL (P < 0.05). AL and PUL had similar axial, torsion, and failure measures, as did AUL and DUL constructs. All but 2 specimens fractured before medial gap closure during failure tests. Drop-offs on load-displacement curves confirmed all failures. Only the screw nearest the gap had significant effect on torsional and failure stiffness but not axial stiffness. Construct mechanics depended on the type of screw placed in this position. This screw nearest the fracture dictates working length stiffness when the working length itself is constant and in turn determines overall construct stiffness in osteoporotic bone.

  1. [Treatment of pediatric distal femur fractures by external fixator combined with limited internal fixation].

    PubMed

    Wei, Sheng-wang; Shi, Zhan-ying; Hu, Ju-zheng; Wu, Hao

    2016-03-01

    To discuss the clinical effects of external fixator combined with limited internal fixation in the treatment of pediatric distal femur fractures. From January 2008 to June 2014, 17 children of distal femur fractures were treated by external fixator combined with limited internal fixation. There were 12 males and 5 females, aged from 6 to 13 years old with an average of 10.2 years, ranged in the course of disease from 1 h to 2 d. Preoperative diagnoses were confirmed by X-ray films in all children. There were 11 patients with supracondylar fracture , and 6 patients with intercondylar comminuted fracture. According to AO/ASIF classification, 9 fractures were type A1, 5 cases were type A2,and 3 cases were type C1. The intraoperative and postoperative complications, postoperative radiological examination, lower limbs length and motion of knee joints were observed. Knee joint function was assessed by KSS score. All the patients were followed up from 6 to 38 months with an average of 24.4 months. No nerve or blood vessel injury was found. One case complicated with the external fixation loosening, 2 cases with the infection of pin hole and 3 cases with the leg length discrepancy. Knee joint mobility and length measurement (compared with the contralateral), the average limited inflexion was 10 degrees (0 degrees to 20 degrees), the average limited straight was 4 degrees (0 degrees to 10), the average varus or valgus angle was 3 degrees (0 degrees to 5 degrees). KSS of the injured side was (96.4 +/- 5.0) points at final follow-up, 16 cases got excellent results and 1 good. All fractures obtained healing and no epiphyseal closed early was found. External fixator combined with limited internal fixation has advantages of simple operation, reliable fixation, early functional exercise in treating pediatric distal femurs fractures.

  2. [Antero-medial incision of knee joint for the treatment of intercondylar fracture of femur].

    PubMed

    Yin, Zi-Fei; Sun, Bin-Feng; Yang, Xiao-Hai; Wang, Qing; Qian, Ping-Kang; Wu, Xiao-Feng; Xu, Feng

    2017-12-25

    To explore the clinical effect of antero-medial incision of knee joint in treating intercondylar fracture of femur. From September 2012 to March 2015, 24 patients with intercondylar fracture of femur were selected, including 17 males and 7 females, aged from 20 to 65 years old with an average of(38.3±9.5) years old. Among them, 12 cases were caused by traffic accident, 8 cases were caused by falling injury and 4 cases were caused by falling down. All patients were closed fractures. The time from injury to hospital was from 30 min to 8 h with an average of(2.2±0.3) h. According to AO classification, 4 cases were type B1, 3 type B2, 2 type B3, 5 type C1, 6 type C2 and 4 type C3. All patients were treated with antero-medial incision of knee joint. Operative time, blood loss and postoperative complications were observed and recovery of keen function was evaluated by Kolmert scoring. All patients were followed-up from 6 to 12 months with average of (9.0±1.7) months. Operative time ranged from 50 to 90 min with an average of (70.0±8.2) min; blood loss ranged from 90 to 400 ml with an average of (180±36) ml; negative pressure flow was from 30 to 90 ml, with an average of (50.0±7.1) ml. All fracture were healed at stage I without loosening of internal fixator, fracture nonunion, and deep vein thrombosis. According to Kolmert scoring, 16 patients got excellent result, 5 patients good and 3 fair. Antero-medial incision of knee joint in treating intercondylar fracture of femur, which has advantages of good fracture reduction, less injury of soft tissue and simple operation, could obtain good clinical results.

  3. Biomechanical Testing of a 3-Hole versus a 4-Hole Sliding Hip Screw in the presence of a Retrograde Intramedullary Nail for Ipsilateral Intertrochanteric and Femur Shaft Fractures.

    PubMed

    Olsen, Michael; Goshulak, Peter; Crookshank, Meghan C; Moktar, Joel; Brazda, Ignace J; Schemitsch, Emil H; Zdero, Radovan

    2018-04-03

    The goal of this study was to compare a 3-hole vs. a 4-hole sliding hip screw (SHS) in the presence of a retrograde intramedullary (RIM) nail for fixing intertrochanteric and comminuted midshaft femur fractures. Mechanical tests were performed on 10 matched pairs of human cadaveric femurs that were osteotomized and then fixed using a 3-hole SHS vs. the traditional "gold standard" 4-hole SHS in the presence of a RIM nail. Data showed no differences between the 3-hole SHS with RIM nail vs. 4-hole SHS with RIM nail for stiffness (281 +/- 127 vs. 260 +/- 118 N/mm, p=0.76), clinical failure at 10 mm of hip displacement (2014 +/- 363 vs. 2134 +/- 614 N, p=0.52), or ultimate mechanical failure (3476 +/- 776 vs. 3669 +/- 755 N, p=0.12). For this fracture pattern, a 3-hole SHS with RIM nail may be a suitable surgical alternative to the traditional "gold standard" method, since it provides the same biomechanical properties while potentially reducing surgical time, blood loss, and hardware used. Level III biomechanical study.

  4. Location of Femoral Fractures in Patients with Different Weight Classes in Fall and Motorcycle Accidents: A Retrospective Cross-Sectional Analysis.

    PubMed

    Chang, Meng-Wei; Liu, Hang-Tsung; Huang, Chun-Ying; Chien, Peng-Chen; Hsieh, Hsiao-Yun; Hsieh, Ching-Hua

    2018-05-27

    This study aimed to determine the incidence of femoral fracture location in trauma patients with different weight classes in fall and motorcycle accidents. A total of 2647 hospitalized adult patients with 2760 femoral fractures from 1 January 2009 to 31 December 2014 were included in this study. Femoral fracture sites were categorized based on their location: proximal femur (type A, trochanteric; type B, neck; and type C, head), femoral shaft, and distal femur. The patients were further classified as obese (body mass index [BMI] of ≥30 kg/m²), overweight (BMI of.

  5. Robust QCT/FEA Models of Proximal Femur Stiffness and Fracture Load During a Sideways Fall on the Hip

    PubMed Central

    Dragomir-Daescu, Dan; Buijs, Jorn Op Den; McEligot, Sean; Dai, Yifei; Entwistle, Rachel C.; Salas, Christina; Melton, L. Joseph; Bennet, Kevin E.; Khosla, Sundeep; Amin, Shreyasee

    2013-01-01

    Clinical implementation of quantitative computed tomography-based finite element analysis (QCT/FEA) of proximal femur stiffness and strength to assess the likelihood of proximal femur (hip) fractures requires a unified modeling procedure, consistency in predicting bone mechanical properties, and validation with realistic test data that represent typical hip fractures, specifically, a sideways fall on the hip. We, therefore, used two sets (n = 9, each) of cadaveric femora with bone densities varying from normal to osteoporotic to build, refine, and validate a new class of QCT/FEA models for hip fracture under loading conditions that simulate a sideways fall on the hip. Convergence requirements of finite element models of the first set of femora led to the creation of a new meshing strategy and a robust process to model proximal femur geometry and material properties from QCT images. We used a second set of femora to cross-validate the model parameters derived from the first set. Refined models were validated experimentally by fracturing femora using specially designed fixtures, load cells, and high speed video capture. CT image reconstructions of fractured femora were created to classify the fractures. The predicted stiffness (cross-validation R2 = 0.87), fracture load (cross-validation R2 = 0.85), and fracture patterns (83% agreement) correlated well with experimental data. PMID:21052839

  6. Retrograde nailing for distal third femoral shaft fractures: a prospective study.

    PubMed

    Acharya, K N; Rao, M R

    2006-12-01

    To evaluate the postoperative knee function and results of unreamed retrograde nailing for distal third femoral shaft fractures. Between January 2002 and 2003 inclusive, a consecutive series of 27 patients (with 28 fractures) who underwent retrograde nailing were prospectively evaluated. Outcome measures were union time, initiation of weight bearing, deformity and shortening, functional length of the nail, knee function assessed using a modified Knee Society Knee Score. Correlations between union time and other variables were also studied. In these patients 26 (93%) of the 28 fractures achieved union, of which 5 underwent dynamisation; the mean union time for the other 21 fractures was 4.4 months. Angular malalignment was present in 4 patients and shortening in 4 others. There was negligible correlation between union time and variables of nail-canal diameter mismatch, functional length of nail, fracture geometry, or initiation of partial weight bearing ambulation. Knee flexion of more than 100 degrees was achieved in 26 patients. 19 patients had anterior knee pain and 10 had instability. By the end of one year, excellent or good scores for pain and function were recorded in 77% and 73% respectively, of the 26 patients. In view of such favourable union rates but significant deterioration in overall knee joint function, at best retrograde nailing is a reliable alternative in the management of selected complicated fractures of the distal femoral shaft.

  7. CORRELATION BETWEEN TIME UNTIL SURGICAL TREATMENT AND MORTALITY AMONG ELDERLY PATIENTS WITH FRACTURES AT THE PROXIMAL END OF THE FEMUR.

    PubMed

    Arliani, Gustavo Gonçalves; da Costa Astur, Diego; Linhares, Glauber Kazuo; Balbachevsky, Daniel; Fernandes, Hélio Jorge Alvachian; Dos Reis, Fernando Baldy

    2011-01-01

    The primary aim of this study was to analyze the possible association between delay in receiving surgical treatment and mortality among elderly patients with fractures at the proximal end of the femur. 269 patients with fractures at the proximal end of the femur (femur neck and intertrochanteric fractures) who were treated surgically at Hospital São Paulo, UNIFESP, São Paulo, between January 2003 and December 2007, were studied. The following attributes were analyzed and compared with the literature relating to this subject: sex, age, type of fracture, classification of the fracture, affected side, synthesis used, trauma mechanism, length of hospitalization, waiting time for surgery, associated comorbidities, hemogram on admission, type of anesthesia, need for blood transfusion, day of the week and season of the year of the fracture. The study showed that higher mortality correlated with higher numbers of clinical comorbidities, longer hospitalization and use of general anesthesia during the surgery. There was no association between the time spent waiting for surgery and mortality.

  8. Bone Parameters and Risk of Hip and Femur Fractures in Patients on Hemodialysis

    PubMed Central

    Hazzan, Azzour D.; Jhaveri, Kenar D.; Ma, Lin; Lacson, Eduardo

    2016-01-01

    Background and objectives Patients on hemodialysis have a high rate of hip fractures. In this study, we performed a contemporary analysis of mineral and bone parameters and their relationship to hip and femur fracture risk. Design, setting, participants, & measurements Patients on hemodialysis treated between 2000 and 2013 in Fresenius Medical Care North America facilities were included. Predictors were on the basis of data as of December 31 of each baseline year and time-averaged values of selected laboratory parameters and medication doses throughout the year. Four period cohorts were constructed from baseline years: 2000, 2003, 2006, and 2009. Follow-up for each cohort was ≤3 years. Results The incidence of hip and femur fractures remained generally unchanged (P=0.40), except among patients who were white and >65 years of age, in whom the rate decreased significantly over the 14-year period (P<0.01). Results from combined multivariable models indicated that the lowest quartiles of time–averaged intact parathyroid hormone were independently associated with higher hip fracture risk (intact parathyroid hormone =181–272 pg/ml: hazard ratio, 1.20; 95% confidence interval [95% CI], 1.03 to 1.41 and intact parathyroid hormone <181 pg/ml: hazard ratio, 1.20; 95% CI, 1.01 to 1.44; referent third quartile, 273 to <433 pg/ml). The lowest quartile of time–averaged serum calcium was also associated with higher risk (calcium <8.7 mg/dl; hazard ratio, 1.17; 95% CI, 1.00 to 1.37) compared with the referent third quartile of 9.1 to <9.5 mg/dl. Conclusions We found an association between lower levels of intact parathyroid hormone and serum calcium and greater risk for hip and femur fractures among patients on hemodialysis. These findings support additional research toward elucidating long-term safety of treatment approaches for hyperparathyroidism in patients with ESRD. PMID:27026521

  9. Atypical Femoral Shaft Fractures in Female Bisphosphonate Users Were Associated with an Increased Anterolateral Femoral Bow and a Thicker Lateral Cortex: A Case-Control Study.

    PubMed

    Jang, Seung Pil; Yeo, Ingwon; So, Sang-Yeon; Kim, Keunbyuel; Moon, Young-Wan; Park, Youn-Soo; Lim, Seung-Jae

    2017-01-01

    The purpose of our study was to investigate the radiographic characteristics of atypical femoral shaft fractures (AFSFs) in females with a particular focus on femoral bow and cortical thickness. We performed a fracture location-, age-, gender-, and ethnicity-matched case-control study. Forty-two AFSFs in 29 patients and 22 typical osteoporotic femoral shaft fractures in 22 patients were enrolled in AFSF group and control group, respectively. With comparing demographics between two groups, radiographically measured femoral bow and cortical thicknesses of AFSF group were compared with control group. All AFSF patients were females with a mean age of 74.4 years (range, 58-85 years). All had a history of bisphosphonate (BP) use with a mean duration of 7.3 years (range 1-17 years). Femoral bow of AFSF group was significantly higher than control group on both anteroposterior (AP) and lateral radiographs after age correction. Mean femoral bow on an AP radiograph was 12.39° ± 5.38° in AFSF group and 3.97 ± 3.62° in control group ( P < 0.0001). Mean femoral bow on the lateral radiograph was 15.71° ± 5.62° in AFSF group and 10.72° ± 4.61° in control group (after age correction P = 0.003). And cortical thicknesses of AFSF group demonstrated marked disparity between tensile and compressive side of bowed femurs in this study. An adjusted lateral cortical thickness was 10.5 ± 1.4 mm in AFSF group and 8.1 ± 1.3 mm in control group (after age correction P < 0.0001) while medial cortical thickness of AFSF group was not statistically different from control group. Correlation analysis showed that the lateral femoral bow on the AP radiograph was solely related to lateral CTI ( R = 0.378, P = 0.002). AFSFs in female BP users were associated with an increased anterolateral femoral bow and a thicker lateral cortex of femurs.

  10. Does the Angle of the Nail Matter for Pertrochanteric Fracture Reduction? Matching Nail Angle and Native Neck-Shaft Angle.

    PubMed

    Parry, Joshua A; Barrett, Ian; Schoch, Bradley; Yuan, Brandon; Cass, Joseph; Cross, William

    2018-04-01

    To determine whether fixation of pertrochanteric hip fractures with cephalomedullary nails (CMNs) with a neck-shaft angle (NSA) less than the native NSA affects reduction and lag screw cutout. Retrospective comparative study. Level I trauma center. Patients treated with a CMN for unstable pertrochanteric femur fractures (OTA/AO 31-A2.2 and 31-A2.3) between 2005 and 2014. CMN fixation. NSA reduction and lag screw cutout. Patients fixed with a nail angle less than their native NSA were less likely to have good reductions [17% vs. 60%, 95% confidence interval (CI), -63% to -18%; P = 0.0005], secondary to more varus reductions (41% vs. 10%, 95% CI, 9%-46%; P = 0.01) and more fractures with ≥4 mm of displacement (63% vs. 35%, 95% CI, 3%-49%; P = 0.03). The cutout was not associated with the use of a nail angle less than the native NSA (60% vs. 76%, 95% CI, -56% to 18%; P = 0.5), varus reductions (60% vs. 32%, 95% CI, -13% to 62%; P = 0.3), or poor reductions (20% vs. 17%, 95% CI, -24% to 44%; P = 1.0). The fixation of unstable pertrochanteric hip fractures with a nail angle less than the native NSA was associated with more varus reductions and fracture displacement but did not affect the lag screw cutout. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  11. The effect of canal fill on paediatric femur fractures treated with titanium elastic nails.

    PubMed

    Nielsen, E; Bonsu, N; Andras, L M; Goldstein, R Y

    2018-02-01

    Traditional teaching for fixation of paediatric femur fractures recommends 80% nail diameter/medullary canal diameter ratio (ND/MCD) for successful maintenance of reduction. Prior studies have investigated this with stainless steel Enders nails. Our aim was to assess the impact of ND/MCD on maintenance of reduction and malunion rates in paediatric femur fractures treated with flexible intramedullary nails (FINs). Retrospective data was collected on all paediatric patients treated with FINs for diaphyseal femur fractures at a single tertiary care institution over a ten-year period. Patients with co-morbidities affecting bone quality were excluded. Patients were subdivided into groups based on ND/MCD. A total of 66 patients met inclusion criteria. Mean ND/MCD was 76.3% (32.9% to 98.8%, SD 14.3). In all, 50% (n = 33/66) of patients had > 80% ND/MCD, and only 13.6% (n = 9/66) of patients had less than 60% ND/MCD. When controlling for fracture stability, ND/MCD had no correlation with mean shortening (p = 0.07) There was no correlation between ND/MCD and angulation in the sagittal (p = 0.96) or coronal plane (p = 0.20). Three patients fit malunion criteria. ND/MCD for these patients were 40%, 67% and 79%. There was no correlation between ND/MCD and shortening or malangulation. The majority of patients in this series with less than 80% fill with FIN healed within acceptable parameters. III.

  12. Body mass index as a prognostic factor for fracturing of the proximal extremity of the femur: a case–control study☆☆☆

    PubMed Central

    Pagani, Renato Cavanus; Kunz, Rodrigo Ernesto; Girardi, Ricardo; Guerra, Marcelo

    2014-01-01

    Objectives To compare the body mass index (BMI) of patients with fractures in the proximal extremity of the femur with the BMI of patients without any previous history of fractures. Methods We investigated patients of both sexes, aged 65 years or over, who were admitted to Hospital Independência, Hospital Beneficência Portuguesa or ULBRA University Hospital, between December 2007 and December 2010, with histories of low-energy trauma such as falling from a standing position. These individuals were compared with patients of the same age but without any history of fracturing of the proximal extremity of the femur (n = 89), who were attended at the geriatrics outpatient clinic of the Sociedade Porto-Alegrense de Auxílio aos Necessitados (SPAAN). Results The age group of the patients with fractures in the proximal extremity of the femur ranged from 65 to 96 years (mean: 77.58). The main type of fracture was trochanteric (47; 62.2%), followed by femoral neck fractures (27; 36%). Among the patients who presented on fracturing the proximal extremity of the femur, 12% had low weight, 62.7% normal weight, 24% overweight, and 1.3% obesity. Among the patients without any history of fractures, 5.6% presented low weight, 43.8% normal weight, 33.7% overweight, and 9.8% obesity. It was observed that the patients with fractures in the proximal extremity of the femur (n = 75) presented a mean BMI of 22.6, while the patients without fractures presented a mean BMI of 25.5. Conclusion The patients in the group with fractures were significantly taller than those in the group without fractures and presented significantly lower BMI than those in the group without fractures. PMID:26229845

  13. Complications of short versus long cephalomedullary nail for intertrochanteric femur fractures, minimum 1 year follow-up.

    PubMed

    Vaughn, Josh; Cohen, Eric; Vopat, Bryan G; Kane, Patrick; Abbood, Emily; Born, Christopher

    2015-05-01

    Hip fractures are becoming increasingly common resulting in significant morbidity, mortality and raising healthcare costs. Both short and long cephalomedullary devices are currently employed to treat intertrochanteric hip fractures. However, which device is optimal continues to be debated as each implant has unique characteristics and theoretical advantages. This study looked to identify rates of complications associated with both long and short cephalomedullary nails for the treatment of intertrochanteric hip fractures. We retrospectively reviewed charts from 2006 to 2011, and we identified 256 patients were identified with AO class 31.1-32.3 fractures. Sixty were treated with short nails and 196 with long nails. Radiographs and charts were then analysed for failures and hardware complications. Catastrophic failure and hardware complication rates were not statistically different between short or long cephalomedullary nails. The overall catastrophic failure rate was 3.1 %; there was a 5 % failure rate in the short-nail group compared with a 2.6 % failure rate in the long-nail group (p = 0.191). There was a 3.33 % secondary femur fracture rate in the short-nail group, compared with none in the long-nail cohort (p = 0.054). The rate of proximal fixation failure was 1.67 % for the short-nail group and 2.0 % in the long-nail group (p = 0.406). Our data suggests equivocal outcomes as measured by similar catastrophic failure rate between both short and long cephalomedullary nails for intertrochanteric femur fractures. However, there was an increased risk of secondary femur fracture with short cephalomedullary nails when compared to long nails that approached statistical significance.

  14. [Direct medical costs of hospital treatment of fractures of the upper extremity of the femur].

    PubMed

    El Ayoubi, Abdelghani; Bouhelo, Kevin Parfait Bienvenu; Chafik, Hachem; Nasri, Mohammed; El Idrissi, Mohammed; Shimi, Mohammed; El Ibrahimi, Abdelhalim; Elmrini, Abdelmajid

    2017-01-01

    Fractures of the upper extremity of the femur are serious because of their morbidity and social and/or economic consequences. They have been the subject of several studies of world literature concerning their hospital treatment, evolution and prevention. The increase in the incidence of this pathology seems unavoidable due to population ageing and to the lengthening life expectancy; it is posing a real long-term public health problem whose importance will be further increased by the need to control health care costs. The results of this study show that the average age of onset of fracture of the proximal extremity of the femur is 68,13 ± 16.9 years, with a male predominance and a sex ratio of 1.14. In our study pertrochanterian fractures represented 69.4% of cases. Direct medical costs of the hospital treatment of fractures of the upper extremity of the femur at the Hassan II University Hospital were £387 714,38 in 222 cases, with an average cost of £1757,4 , including costs for patient's stay in hospital, which represented the majority of expenses ( 77% of total costs). It is desirable to raise staff awareness of the costs of consumables in order to reduce treatment costs and to adopt cost-oriented behaviour. Length of stay should be limited to the maximum extent because it only allows to reduce staff and accommodation costs.

  15. Biomechanical Study of the Fixation Strength of Anteromedial Plating for Humeral Shaft Fractures

    PubMed Central

    Zheng, Yin-Feng; Zhou, Jun-Lin; Wang, Xiao-Hong; Shan, Lei; Liu, Yang

    2016-01-01

    Background: Open reduction and internal fixation with plate and screws are the gold standard for the surgical treatment of humeral shaft fractures, this study was to compare the mechanical properties of anteromedial, anterolateral, and posterior plating for humeral shaft fractures. Methods: A distal third humeral shaft fracture model was constructed using fourth-generation sawbones (#3404, composite bone). A total of 24 sawbones with a distal third humeral shaft fracture was randomly divided into three Groups: A, B, and C (n = 8 in each group) for anteromedial, anterolateral, and posterior plating, respectively. All sawbones were subjected to horizontal torsional fatigue tests, horizontal torsional and axial compressive fatigue tests, four-point bending fatigue tests in anteroposterior (AP) and mediolateral (ML) directions and horizontal torsional destructive tests. Results: In the horizontal torsional fatigue tests, the mean torsional angle amplitude in Groups A, B, and C were 6.12°, 6.53°, and 6.81°. In horizontal torsional and axial compressive fatigue tests, the mean torsional angle amplitude in Groups A, B, and C were 5.66°, 5.67°, and 6.36°. The mean plate displacement amplitude was 0.05 mm, 0.08 mm, and 0.10 mm. Group A was smaller than Group C (P < 0.05). In AP four-point bending fatigue tests, the mean plate displacement amplitude was 0.16 mm, 0.13 mm, and 0.20 mm. Group B was smaller than Group C (P < 0.05). In ML four-point bending fatigue tests, the mean plate displacement amplitude were 0.16 mm, 0.19 mm, and 0.17 mm. In horizontal torsional destructive tests, the mean torsional rigidity in Groups A, B, and C was 0.82, 0.75, and 0.76 N·m/deg. The yielding torsional angle was 24.50°, 25.70°, and 23.86°. The mean yielding torque was 18.46, 18.05, and 16.83 N·m, respectively. Conclusions: Anteromedial plating was superior to anterolateral or posterior plating in all mechanical tests except in AP four-point bending fatigue tests compared to the

  16. Biomechanical Study of the Fixation Strength of Anteromedial Plating for Humeral Shaft Fractures.

    PubMed

    Zheng, Yin-Feng; Zhou, Jun-Lin; Wang, Xiao-Hong; Shan, Lei; Liu, Yang

    2016-08-05

    Open reduction and internal fixation with plate and screws are the gold standard for the surgical treatment of humeral shaft fractures, this study was to compare the mechanical properties of anteromedial, anterolateral, and posterior plating for humeral shaft fractures. A distal third humeral shaft fracture model was constructed using fourth-generation sawbones (#3404, composite bone). A total of 24 sawbones with a distal third humeral shaft fracture was randomly divided into three Groups: A, B, and C (n = 8 in each group) for anteromedial, anterolateral, and posterior plating, respectively. All sawbones were subjected to horizontal torsional fatigue tests, horizontal torsional and axial compressive fatigue tests, four-point bending fatigue tests in anteroposterior (AP) and mediolateral (ML) directions and horizontal torsional destructive tests. In the horizontal torsional fatigue tests, the mean torsional angle amplitude in Groups A, B, and C were 6.12°, 6.53°, and 6.81°. In horizontal torsional and axial compressive fatigue tests, the mean torsional angle amplitude in Groups A, B, and C were 5.66°, 5.67°, and 6.36°. The mean plate displacement amplitude was 0.05 mm, 0.08 mm, and 0.10 mm. Group A was smaller than Group C (P < 0.05). In AP four-point bending fatigue tests, the mean plate displacement amplitude was 0.16 mm, 0.13 mm, and 0.20 mm. Group B was smaller than Group C (P < 0.05). In ML four-point bending fatigue tests, the mean plate displacement amplitude were 0.16 mm, 0.19 mm, and 0.17 mm. In horizontal torsional destructive tests, the mean torsional rigidity in Groups A, B, and C was 0.82, 0.75, and 0.76 N·m/deg. The yielding torsional angle was 24.50°, 25.70°, and 23.86°. The mean yielding torque was 18.46, 18.05, and 16.83 N·m, respectively. Anteromedial plating was superior to anterolateral or posterior plating in all mechanical tests except in AP four-point bending fatigue tests compared to the anterolateral plating group. We can suggest

  17. Outcome of nonoperative management of displaced oblique spiral fractures of the fifth metatarsal shaft.

    PubMed

    Aynardi, Michael; Pedowitz, David I; Saffel, Heather; Piper, Christine; Raikin, Steven M

    2013-12-01

    Nonoperative management has been the preferred treatment for displaced oblique spiral fractures of the fifth metatarsal shaft; yet a paucity of literature supports this claim. The purpose of this investigation was to report the incidence and long-term outcome in the largest cohort of these fractures reported to date. From 2006 through 2010, 2990 patients sustaining closed metatarsal fractures were seen and treated. Displaced, oblique, spiral fractures of the distal shaft of the fifth metatarsal were identified and follow-up was conducted. Only patients who were initially treated with nonoperative management were included. Patients were seen at 6 and 12 weeks, and a minimum 2-year follow-up was conducted. In addition, demographic information was obtained, and the Short Form-12 (SF-12) and Foot and Ankle Ability Measure (FAAM) were administered. Average follow-up was 3.5 years. In all, 142 acute fractures were managed for an incidence of 4.8% of all metatarsal fractures. There were 117 females and 25 males, average age was 55. FAAM activities of daily living subscale scores averaged 95.5 (±5.7), while FAAM sports subscales were 92.7 (±9.1). SF-12 physical and mental scores averaged 51.4 (±4.9) and 50.3 (±4.6), respectively. There were 2 delayed unions, 1 asymptomatic nonunion treated nonoperatively, and 2 painful nonunions that required open reduction internal fixation with bone grafting. This large cohort described the relative incidence and functional outcomes of displaced oblique fracture of shaft of the fifth metatarsal bone treated nonoperatively. Nonoperative management of these fractures resulted in excellent, long-term functional outcomes. Level II, prospective cohort study.

  18. Paediatric tibial shaft fractures treated by open reduction and stabilization with monolateral external fixation

    PubMed Central

    Simon, A.-L.; Apostolou, N.; Vidal, C.; Ferrero, E.; Mazda, K.; Ilharreborde, B.

    2018-01-01

    Abstract Purpose Elastic stable intramedullary nailing is increasingly used for surgical treatment of tibial shaft fractures, but frequently requires immobilization and delayed full weight-bearing. Therefore, external fixation remains interesting. The aim was to report clinico-radiological outcomes of monolateral external fixation for displaced and unstable tibial shaft fractures in children. Methods All tibial fractures consecutively treated by monolateral external fixation between 2008 and 2013 were followed. Inclusion criteria included skeletal immaturity and closed and open Gustilo I fractures caused by a direct impact. Patients were seen until two years postoperatively. Demographics, mechanism of injury, surgical data and complications were recorded. Anteroposterior and lateral side radiographs were performed at each visit. Full-limb 3D reconstructions using biplanar stereroradiography was performed for final limb length and alignment measures. Results A total of 45 patients (mean age 9.7 years ± 0.5) were included. In all, 17 were Gustilo I fractures, with no difference between open and closed fractures for any data. Mean time to full weight bearing was 18.2 days ± 0.7. After 15 days, 39 patients returned to school. Hardware removal (mean time to union 15.6 weeks ± 0.8) was performed during consultation under analgesic gas. There were no cases of nonunion. No fracture healed with > 10° of angulation (mean 5.1° ± 0.4°). Leg-length discrepancy > 10 mm was found for six patients. Conclusions This procedure can be a safe and simple surgical treatment for children with tibial shaft fractures. Few complications and early return to school were reported, with the limitations of non-comparative study. Level of Evidence IV PMID:29456750

  19. Internal derangement of the knee after ipsilateral femoral shaft fracture: MR imaging findings.

    PubMed

    Blacksin, M F; Zurlo, J V; Levy, A S

    1998-08-01

    This study uses magnetic resonance (MR) imaging to delineate the types and frequencies of injuries seen in the knee after ipsilateral femoral shaft fracture. We also compare the results of the orthopedic knee examination with the MR findings. MR imaging of the ipsilateral knee was performed on 34 patients with closed femoral shaft fractures. Indications for knee MR imaging included knee pain at the time of fracture, soft tissue swelling or an effusion of the knee, or a positive knee examination under anesthesia. The patients had a mean age of 27 years and all were stabilized with intramedullary nails. Imaging was performed a mean time of 2.5 days after surgery. All patients had knee examinations done under anesthesia, and the MR results were compiled and compared with the clinical examinations. Ninety-seven percent of patients demonstrated knee effusions. Twenty-seven percent of patients demonstrated meniscal tears, with the posterior horn of the medial meniscus most frequently torn. The medial collateral ligament was the most frequent site of ligamentous injury (38%) followed by the posterior cruciate ligament (21%). Fifty percent of patients had injuries of the extensor mechanism. Bone bruises were noted in 32% of patients. Articular cartilage injuries were confined to the patella in four cases. One occult tibial plateau fracture and one meniscocapsular separation were seen. There is a common incidence of both ligamentous and meniscal injury to the knee after ipsilateral femoral shaft fracture. MR imaging can be useful in assessing the extent of injury, and may reveal findings unsuspected after clinical examination of the knee.

  20. Indirect reduction technique using a distraction support in minimally invasive percutaneous plate osteosynthesis of tibial shaft fractures.

    PubMed

    Dong, Wen-Wei; Shi, Zeng-Yuan; Liu, Zheng-Xin; Mao, Hai-Jiao

    2016-12-01

    To describe an indirect reduction technique during minimally invasive percutaneous plate osteosynthesis (MIPPO) of tibial shaft fractures with the use of a distraction support. Between March 2011 and October 2014, 52 patients with a mean age of 48 years (16-72 years) sustaining tibial shaft fractures were included. All the patients underwent MIPPO for the fractures using a distraction support prior to insertion of the plate. Fracture angular deformity was assessed by goni- ometer measurement on preoperative and postoperative images. Preoperative radiographs revealed a mean of 7.6°(1.2°-28°) angulation in coronal plane and a mean of 6.8°(0.5°-19°) angulation in sagittal plane. Postoperative anteroposterior and lateral radio- graphs showed a mean of 0.8°(0°-4.0°) and 0.6°(0°-3.6°) of varus/valgus and apex anterior/posterior angulation, respectively. No intraoperative or postoperative complications were noted. This study suggests that the distraction support during MIPPO of tibial shaft fractures is an effective and safe method with no associated complications.

  1. Internal fixators: a safe option for managing distal femur fractures?

    PubMed Central

    Batista, Bruno Bellaguarda; Salim, Rodrigo; Paccola, Cleber Antonio Jansen; Kfuri, Mauricio

    2014-01-01

    OBJECTIVE: Evaluate safety and reliability of internal fixator for the treatment of intra-articular and periarticular distal femur fractures. METHODS: Retrospective data evaluation of 28 patients with 29 fractures fixed with internal fixator was performed. There was a predominance of male patients (53.5%), with 52% of open wound fractures, 76% of AO33C type fractures, and a mean follow up of 21.3 months. Time of fracture healing, mechanical axis deviation, rate of infection and postoperative complications were registered. RESULTS: Healing rate was 93% in this sample, with an average time of 5.5 months. Twenty-seven percent of patients ended up with mechanical axis deviation, mostly resulting from poor primary intra-operative reduction. There were two cases of implant loosening; two implant breakage, and three patients presented stiff knee. No case of infection was observed. Healing rate in this study was comparable with current literature; there was a high degree of angular deviation, especially in the coronal plane. CONCLUSION: Internal fixators are a breakthrough in the treatment of knee fractures, but its use does not preclude application of principles of anatomical articular reduction and mechanical axis restoration. Level of Evidence II, Retrospective Study. PMID:25061424

  2. An Unexpected Complication of Residual Fibular Strut Graft While Performing A Press fit Hemiarthroplasty for A Secondary Nonunion Fracture Neck of the Femur.

    PubMed

    Huda, Najmul; Julfiqar; Pant, Ajay; Aslam, M

    2015-01-01

    Perioperative complications are well known during partial and total hip arthroplasty. One of the common categories of these complications is an intraoperative fractures of the proximal femur. Here we discuss a case of perforation of posteromedial cortex of the proximal femur, while doing a press fit modular bipolar hemiarthroplasty, in a young adult with secondary nonunion of the femoral neck fracture. The cause of this proximal femur perforation was residual fibular strut graft that, redirected the femoral stem into undesirable direction. This complication of residual fibular strut graft has not been disscussed much in the orthopedic literature previously. A press fit modular bipolar hiparthroplasty was performed in a young adult male with nonunion fracture neck of the femur secondary to initial fixation using 6.5mm cannulated hip screws and nonvascularized free fibular strut grafting. Failure to completely remove the fibular strut from the proximal femur lead to difficult negotiation of the femoral stem into the femoral canal and ultimately a perforation in the proximal femur at the level of the lesser trochanter. A revision procedure was done to completely remove the residual fibular graft, and then a fresh press fit modular bipolar hemiarthroplasty was done. Complete removal of fibular strut graft should be done, while performing hip arthroplasty in patients with failed fibular grafting for fracture neck of the femur.

  3. Treatment of humeral shaft fractures using antegrade nailing: functional outcome in the shoulder.

    PubMed

    Patino, Juan Martin

    2015-08-01

    The purpose of this study was to evaluate shoulder outcomes and function after humeral shaft fractures treated with antegrade nailing. Thirty patients with acute humeral shaft fractures who underwent antegrade locked intramedullary nailing were retrospectively studied. Range of motion (ROM) of the affected shoulder was evaluated, comparing it with the nonaffected shoulder, radiologic position of the nails, complications, and need for a second surgery. The study enrolled 20 men and 10 women (average age, 41.9 years). The average follow-up was 35.8 months. The average shoulder elevation averaged 157°, internal rotation was variable (reaching the sacroiliac joint to T7), and external rotation averaged 75°. Elbow flexion-extension ROM averaged 133° (115°-145°). According to the Rodriguez-Merchan criteria, 12 patients achieved excellent results (40%), 7 good (20%), and 6 fair (23.3%); poor results were found in 5 cases (16.6%). Twelve patients achieved full mobility of the shoulder, whereas 18 had some loss of motion, with significant differences between the affected and nonaffected shoulders (P = .001). Decreased shoulder ROM is common after antegrade nailing of humeral shaft fractures. Avoidance of nail impingement can improve final outcomes. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  4. Use of fibular bone graft and cancellous screw fixation in the management of neglected femur neck fractures in young patients.

    PubMed

    Khani, Ghulam Mustafa Kaim; Hafeez, Kamran; Bux, Muhammad; Rasheed, Nusrat; Ahmed, Naveed; Anjum, M Perwez

    2017-01-01

    To present the clinical outcome of patients with neglected femur neck fracture treated with fibular bone graft. During May 2010-February 2013, 15 patients younger than 35 years of age with neglected fracture neck of femur were managed with non-vascularized fibular graft and cannulated screws. Fractures were classified according to Sandhu Classification. Hip function was assessed using Harris hip score. Fifteen patients with mean age of 28.67 years were managed. Mean period of delay from injury to presentation was 3.07 months. Mean follow-up was 18.5 months. Union was achieved in 13 cases. 2 patients developed nonunion with progression of avascular necrosis (AVN). Patients with healed fracture did not show radiological signs of AVN till the past follow-up. Functional status was evaluated at 6 months according to Harris hip score and was poor in 2 patients, fair in 2 patients, good in 6 patients, and excellent in 5 patients. Fibular graft along with two cancellous screws proved to be an effective technique in our cases with neglected femur neck fractures.

  5. Study of the variations of fall induced hip fracture risk between right and left femurs using CT-based FEA.

    PubMed

    Faisal, Tanvir R; Luo, Yunhua

    2017-10-03

    Hip fracture of elderly people-suffering from osteoporosis-is a severe public health concern, which can be reduced by providing a prior assessment of hip fracture risk. Image-based finite element analysis (FEA) has been considered an effective computational tool to assess the hip fracture risk. Considering the femoral neck region is the weakest, fracture risk indicators (FRI) are evaluated for both single-legged stance and sideways fall configurations and are compared between left and right femurs of each subject. Quantitative Computed Tomography (QCT) scan datasets of thirty anonymous patients' left and right femora have been considered for the FE models, which have been simulated with an equal magnitude of load applied to the aforementioned configurations. The requirement of bilateral hip assessment in predicting the fracture risk has been explored in this study. Comparing the sideways fall and single-legged stance, the FRI varies by 64 to 74% at the superior aspects and by 14 to 19% at the inferior surfaces of both the femora. The results of this in vivo analysis clearly substantiate that the fracture is expected to initiate at the superior surface of femoral neck region if a patient falls from his/her standing height. The distributions of FRI between the femurs vary considerably, and the variability is significant at the superior aspects. The p value (= 0.02) obtained from paired sample t-Test yields p value ≤ 0.05, which shows the evidence of variability of the FRI distribution between left and right femurs. Moreover, the comparison of FRIs between the left and right femur of men and women shows that women are more susceptible to hip fracture than men. The results and statistical variation clearly signify a need for bilateral hip scanning in predicting hip fracture risk, which is clinically conducted, at present, based on one hip chosen randomly and may lead to inaccurate fracture prediction. This study, although preliminary, may play a crucial role in

  6. Finite element analysis of functionally graded bone plate at femur bone fracture site

    NASA Astrophysics Data System (ADS)

    Satapathy, Pravat Kumar; Sahoo, Bamadev; Panda, L. N.; Das, S.

    2018-03-01

    This paper focuses on the analysis of fractured Femur bone with functionally graded bone plate. The Femur bone is modeled by using the data from the CT (Computerized Tomography) scan and the material properties are assigned using Mimics software. The fracture fixation plate used here is composed of Functionally Graded Material (FGM). The functionally graded bone plate is considered to be composed of different layers of homogeneous materials. Finite element method approach is adopted for analysis. The volume fraction of the material is calculated by considering its variation along the thickness direction (z) according to a power law and the effective properties of the homogeneous layers are estimated. The model developed is validated by comparing numerical results available in the literature. Static analysis has been performed for the bone plate system by considering both axial compressive load and torsional load. The investigation shows that by introducing FG bone plate instead of titanium, the stress at the fracture site increases by 63 percentage and the deformation decreases by 15 percentage, especially when torsional load is taken into consideration. The present model yields better results in comparison with the commercially available bone plates.

  7. The management of pediatric subtrochanteric femur fractures with a statically locked intramedullary nail.

    PubMed

    Herrera-Soto, José A; Meuret, Robert; Phillips, Jonathan H; Vogel, Daniel J

    2015-01-01

    To evaluate locked intramedullary (IM) fixation as an alternative treatment method for children with subtrochanteric fractures. Retrospective review. Level 1 trauma center in a Children's Hospital. Pediatric patients with subtrochanteric femur fractures with open growth plates. All patients were treated with a lateral entry IM locking nail. Patients were followed until full fracture consolidation or until implant removal. Data on time to full weight bearing, return to full activity, residual pain, any form of gait abnormality, and any other complication from follow-up visits were collected. There were 9 males and 1 female patient with an average age of 12 years and average follow-up of 22 months. Most of the fractures occurred secondary to high-energy trauma. Partial weight bearing was started at 24 days and full at 66 days. Implants were removed on average at 11 months after implantation. There were neither intraoperative complications nor major complications in the postoperative period recorded after removal. Two patients presented with a longer limb on the affected side, both 8 mm, and 2 presented with asymptomatic grade I heterotopic ossification. The use of a statically locked lateral entry IM nail for subtrochanteric femur fractures in children is a safe and efficacious method of treatment with few complications and risks and satisfactory outcomes in children over the age of 8 years. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  8. Head salvage of an infected neck of femur fracture in an adult: a case report.

    PubMed

    Joseph, Christina Marie; Jepegnanam, Thilak Samuel

    2018-05-23

    Head preservation of an infected neck of femur fracture appears to be extremely rare with no described cases in literature till date. We present the outcome of head salvage in a young adult with an infected neck of femur nonunion who in addition had chronic osteomyelitic sequelae of his entire femur with reactivation of latent infection in the distal femoral diaphysis. Osteosynthesis was performed by means of cancellous screw fixation augmented with bone substitute following a failed attempt at salvage with a valgus intertrochanteric osteotomy. The patient had an excellent functional outcome with near normal hip range of movements at a follow-up of 5 years after union.

  9. Physical therapy in the postoperative of proximal femur fracture in elderly. Literature review

    PubMed Central

    Carneiro, Mariana Barquet; Alves, Débora Pinheiro Lédio; Mercadante, Marcelo Tomanik

    2013-01-01

    The proximal femoral fracture in the elderly is a serious public health problem. Surgical treatment of this fracture is used to reduce morbidity, together with postoperative physical therapy. The objective was to conduct a systematic review of physical therapy protocols in postoperative for fractures of the proximal femur in elderly. We selected randomized controlled trials in elderly in the past 10 years, in Portuguese and English. There were 14 articles in the literature. Physical therapy has an important role in functional recovery of the elderly. Level of Evidence I, Systematic Review RCTs (Study results were homogenous). PMID:24453665

  10. Post-traumatic cerebral fat embolism prior to operative repair of femoral and tibial fractures.

    PubMed

    Kim, Kyung-Cheon; Hwang, Deuk-Soo; Shin, Hyun-Dae

    2008-02-01

    Rare cases of primary cerebral fat embolism as a postoperative complication have been reported. In addition, cerebral fat embolism occurring before operative repair without shunt lesion are more rarely reported. We report a patient with a posttraumatic cerebral fat embolism resulting in severe neurologic dysfunction without right to left shunt. A 25-year-old man was brought to the hospital immediately after a traffic accident. He sustained a right segmental femoral shaft fracture and a left tibial shaft fracture. The patient was alert with no neurological deficits. Approximately 13 hours after injury, the patient developed acute mental status deterioration and dyspnea. Magnetic resonance imaging of the brain revealed extensive multifocal infarction owing to embolic showering throughout nearly the entire brain parenchyma. Computed tomography with intravenous contrast revealed no evidence of embolism in the lung, abdomen, and pelvis. Transthoracic and transesophageal echocardiogram revealed no circulating embolic particles or intracardiac shunt. The patient underwent closed reduction and internal fixation with a reamed intramedullary nail in the tibia and underwent open reduction and internal fixation with a reamed nail in the femur at 5 days after injury. We performed decompression of a hematoma containing a large number of lipid droplets via a small incision in the femur shaft fracture, established suction drainage of the tibia medullar cavity, and applied a tourniquet to the thigh in the tibia shaft fracture. Supportive medical treatment included endotracheal ventilatory support and tracheostomy. The patient was discharged from the hospital 50 days after admission. On follow-up 2 months later, he had returned to activities of daily living, however a speech disturbance remained.

  11. Comparison of Percutaneous Cementoplasty with and Without Interventional Internal Fixation for Impending Malignant Pathological Fracture of the Proximal Femur

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tian, Qing-Hua, E-mail: ddqinghua-tian@163.com; He, Cheng-Jian, E-mail: tianhechengjian@163.com; Wu, Chun-Gen, E-mail: 649514608@qq.com

    PurposeTo compare the efficacy of percutaneous cementoplasty (PCP) with and without interventional internal fixation (IIF) on malignant impending pathological fracture of proximal femur.MethodsA total of 40 patients with malignant impending pathological fracture of proximal femur were selected for PCP and IIF (n = 19, group A) or PCP alone (n = 21, group B) in this non-randomized prospective study. Bone puncture needles were inserted into the proximal femur, followed by sequential installation of the modified trocar inner needles through the puncture needle sheath. Then, 15–45 ml cement was injected into the femur lesion.ResultsThe overall excellent and good pain relief rate during follow-ups were significantly highermore » in group A than that in group B (89 vs. 57 %, P = 0.034). The average change of VAS, ODI, KPS, and EFES in group A were significantly higher than those in group B at 1-, 3-, 6-month, 1-year (P < 0.05). Meanwhile, The stability of the treated femur was significantly higher in group A than that in group B (P < 0.05).ConclusionPCP and IIF were not only a safe and effective procedure, but resulted in greater pain relief, bone consolidation, and also reduced the risk of fracture than the currently recommended approach of PCP done on malignant proximal femoral tumor.« less

  12. Bilateral femoral shaft fractures complicated by fat and pulmonary embolism: a case report.

    PubMed

    Randelli, Filippo; Capitani, Paolo; Pace, Fabrizio; Favilla, Sara; Galante, Claudio; Randelli, Pietro

    2015-12-01

    A 25-year-old man was admitted to our hospital because of pulmonary embolism and suspected fat embolism after sustaining bilateral femoral shaft fracture. A left arm weakness, tachycardia and sudden hemoglobin drop delayed his definitive fixation with intramedullary nailing. His clinical course was further complicated by bleeding from the pin sites of the external fixators which had initially been used to temporarily stabilize his femoral fractures (clotting disturbances). A lower leg Doppler ultrasound and a new pelvic-chest CT angiography excluded any remaining thrombus, meanwhile the embolus had broken in smaller pieces, more distally. His unfractionated heparin was revised to a Low Molecular Weight Heparin at prophylactic dose. After a 10 day period and when his condition had been improved bilateral reamed nailing was performed. Although bilateral closed femoral shaft fractures should be stabilized early, fat embolism syndrome (FES) and thromboembolic events (TEV) should always be kept in mind in these patients. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Short-term muscle atrophy caused by botulinum toxin-A local injection impairs fracture healing in the rat femur.

    PubMed

    Hao, Yongqiang; Ma, Yongcheng; Wang, Xuepeng; Jin, Fangchun; Ge, Shengfang

    2012-04-01

    Damaged bone is sensitive to mechanical stimulation throughout the remodeling phase of bone healing. Muscle damage and muscular atrophy associated with open fractures and subsequent fixation are not beneficial to maintaining optimum conditions for mechanical stability. The aim of this study was to investigate whether local muscle atrophy and dysfunction affect fracture healing in a rat femur fracture model. We combined the rat model of a short period atrophy of the quadriceps with femur fracture. Forty-four-month-old male Wistar rats were adopted for this study. Two units of botulinum toxin-A (BXTA) were administered locally into the right side of the quadriceps of each rat, while the same dose of saline was injected into the contralateral quadriceps. After BXTA had been fully absorbed by the quadriceps, osteotomy was performed in both femurs with intramedullary fixation. Gross observation and weighing of muscle tissue, X-ray analysis, callus histology, and bone biomechanical testing were performed at different time points up to 8 weeks post-surgery. Local injection of BXTA led to a significant decrease in the volume and weight of the quadriceps compared to the control side. At the eighth week, the left side femurs of the saline-injected quadriceps almost reached bony union, and fibrous calluses were completely calcified into woven bone. However, a gap was still visible in the BXTA-treated side on X-ray images. As showed by bone histology, there were no mature osseous calluses or woven bone on the BXTA-treated side, but a resorption pattern was evident. Biomechanical testing indicated that the femurs of the BXTA-treated side exhibited inferior mechanical properties compared with the control side. The inferior outcome following BXTA injection, compared with saline injection, in terms of callus resistance may be the consequence of unexpected load and mechanical unsteadiness caused by muscle atrophy and dysfunction. Copyright © 2011 Orthopaedic Research Society.

  14. Use of a statistical model of the whole femur in a large scale, multi-model study of femoral neck fracture risk.

    PubMed

    Bryan, Rebecca; Nair, Prasanth B; Taylor, Mark

    2009-09-18

    Interpatient variability is often overlooked in orthopaedic computational studies due to the substantial challenges involved in sourcing and generating large numbers of bone models. A statistical model of the whole femur incorporating both geometric and material property variation was developed as a potential solution to this problem. The statistical model was constructed using principal component analysis, applied to 21 individual computer tomography scans. To test the ability of the statistical model to generate realistic, unique, finite element (FE) femur models it was used as a source of 1000 femurs to drive a study on femoral neck fracture risk. The study simulated the impact of an oblique fall to the side, a scenario known to account for a large proportion of hip fractures in the elderly and have a lower fracture load than alternative loading approaches. FE model generation, application of subject specific loading and boundary conditions, FE processing and post processing of the solutions were completed automatically. The generated models were within the bounds of the training data used to create the statistical model with a high mesh quality, able to be used directly by the FE solver without remeshing. The results indicated that 28 of the 1000 femurs were at highest risk of fracture. Closer analysis revealed the percentage of cortical bone in the proximal femur to be a crucial differentiator between the failed and non-failed groups. The likely fracture location was indicated to be intertrochantic. Comparison to previous computational, clinical and experimental work revealed support for these findings.

  15. Finite element analysis of locking plate and two types of intramedullary nails for treating mid-shaft clavicle fractures.

    PubMed

    Ni, Ming; Niu, Wenxin; Wong, Duo Wai-Chi; Zeng, Wei; Mei, Jiong; Zhang, Ming

    2016-08-01

    Both plate and intramedullary nail fixations, including straight and anatomic nails, have been clinically adopted for the treatment of displaced mid-shaft clavicle fractures. However, the biomechanical performances of these fixations and implants have not been well evaluated. This study aims to compare the construct stability, stress distribution and fracture micro-motion of three fixations based on finite element (FE) method. The FE model of clavicle was reconstructed from CT images of a male volunteer. A mid-shaft fracture gap was created in the intact clavicle. Three fixation styles were simulated including locking plate (LP), anatomic intramedullary nail (CRx), and straight intramedullary nail (RCP). Two loading scenarios (axial compression and inferior bending) were applied at the distal end of the clavicle to simulate arm abduction, while the sternal end was fixed. Under both conditions, the LP was the stiffest, followed by the CRx, and the RCP was the weakest. LP also displayed a more evenly stress distribution for both implant and bone. RCP had a higher stress compared with CRx in both conditions. Moreover, all implants sustained higher stress level under the loading condition of bending than compression. The plate fixation significantly stabilizes the fracture gap, reduces the implant stress, and serves as the recommended fixation for the mid-shaft clavicle fracture. The CRx is an alternative device to treat clavicle shaft fracture, but the shoulder excessive activities should be avoided after operation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Forecasting Proximal Femur and Wrist Fracture Caused by a Fall to the Side during Space Exploration Missions to the Moon and Mars

    NASA Technical Reports Server (NTRS)

    Lewandowski, Beth E.; Myers, Jerry G.; Sulkowski, C.; Ruehl, K.; Licata, A.

    2008-01-01

    The possibility of bone fracture in space is a concern due to the negative impact it could have on a mission. The Bone Fracture Risk Module (BFxRM) developed at the NASA Glenn Research Center is a statistical simulation that quantifies the probability of bone fracture at specific skeletal locations for particular activities or events during space exploration missions. This paper reports fracture probability predictions for the proximal femur and wrist resulting from a fall to the side during an extravehicular activity (EVA) on specific days of lunar and Martian exploration missions. The risk of fracture at the proximal femur on any given day of the mission is small and fairly constant, although it is slightly greater towards the end of the mission, due to a reduction in proximal femur bone mineral density (BMD). The risk of wrist fracture is greater than the risk of hip fracture and there is an increased risk on Mars since it has a higher gravitational environment than the moon. The BFxRM can be used to help manage the risk of bone fracture in space as an engineering tool that is used during mission operation and resource planning.

  17. Metachronous bilateral subtrochanteric fracture of femur in an osteopetrotic bone: A case report with technical note.

    PubMed

    Kumar, Dharmendra; Jain, Vijay Kumar; Lal, Hitesh; Arya, Rajinder Kumar; Sinha, Skand

    2012-12-01

    Osteopetrosis is a rare inherited skeletal disorder characterized by increased density. The increased fragility of such dense bone results in a greater incidence of fractures, especially around hip and proximal femur. The surgical treatment of such fractures is difficult due to hard but brittle structure of bone. Herein we report a case of bilateral subtrochanteric fracture in an osteopetrotic patient. It was fixed using a dynamic hip screw with plate.

  18. Displaced mid-shaft clavicular fractures: is conservative treatment still preferred?

    PubMed

    Brin, Yaron S; Palmanovich, Ezequiel; Dolev, Eran; Nyska, Meir; Kish, Benyamin J

    2014-12-01

    A clavicular fracture accounts for 2.6%-5% of adult fractures. Fractures in the middle-third (OTA 15-B) represent 69%-82% of all clavicular fractures. There is no consensus among orthopedic surgeons regarding treatment for these fractures: many support conservative treatment even for displaced middle-third clavicular fractures, while others choose operative treatment. To assess the attitudes of orthopedic surgeons regarding treatment of displaced mid-shaft clavicular fractures. We conducted a survey in which we interviewed orthopedic surgeons from various countries during the 2012 EFORT meeting in Berlin. The questionnaire included an X-ray of a displaced middle-third clavicular fracture, as well as questions regarding the surgeon's proposed treatment plan. A total of 177 orthopedic surgeons completed the questionnaire; 49% preferred operative treatment for a displaced middle-third clavicular fracture. Among the orthopedic trauma specialists, 58% suggested operative treatment, as did 82% of shoulder specialists. Most surgeons preferred a locking plate for fixation. The treatment approach for a displaced middle-third clavicular fracture seems to be evenly split between conservative and operative approaches. The tendency toward operative treatment was.even more remarkable among orthopedic trauma specialists and shoulder specialists who completed the questionnaire. Most surgeons prefer a locking plate as a fixation system for this type of fracture.

  19. Recurrent Proximal Femur Fractures in a Teenager With Osteogenesis Imperfecta on Continuous Bisphosphonate Therapy: Are We Overtreating?

    PubMed

    Vasanwala, Rashida F; Sanghrajka, Anish; Bishop, Nicholas J; Högler, Wolfgang

    2016-07-01

    Long-term bisphosphonate (BP) therapy in adults with osteoporosis is associated with atypical femoral fractures, caused by increased material bone density and prolonged suppression of bone remodeling which may reduce fracture toughness. In children with osteogenesis imperfecta (OI), long-term intravenous BP therapy improves bone structure and mass without further increasing the already hypermineralized bone matrix, and is generally regarded as safe. Here we report a teenage girl with OI type IV, who was started on cyclical intravenous pamidronate therapy at age 6 years because of recurrent fractures. Transiliac bone biopsy revealed classical structural features of OI but unusually low bone resorption surfaces. She made substantial improvements in functional ability, bone mass, and fracture rate. However, after 5 years of pamidronate therapy she started to develop recurrent, bilateral, nontraumatic, and proximal femur fractures, which satisfied the case definition for atypical femur fractures. Some fractures were preceded by periosteal reactions and prodromal pain. Pamidronate was discontinued after 7 years of therapy, following which she sustained two further nontraumatic femur fractures, and continued to show delayed tibial osteotomy healing. Despite rodding surgery, and very much in contrast to her affected, untreated, and normally mobile mother, she remains wheelchair-dependent. The case of this girl raises questions about the long-term safety of BP therapy in some children, in particular about the risk of oversuppressed bone remodeling with the potential for microcrack accumulation, delayed healing, and increased stiffness. The principal concern is whether there is point at which benefit from BP therapy could turn into harm, where fracture risk increases again. This case should stimulate debate whether current adult atypical femoral fracture guidance should apply to children, and whether low-frequency, low-dose cyclical, intermittent, or oral treatment

  20. Clinic research on the treatment for humeral shaft fracture with minimal invasive plate osteosynthesis: a retrospective study of 128 cases.

    PubMed

    Chen, H; Hu, X; Yang, G; Xiang, M

    2017-04-01

    Minimal invasive plate osteosynthesis (MIPO) is one of the most important techniques in the treatment for humeral shaft fractures. This study was performed to evaluate the efficacy of MIPO technique for the treatment for humeral shaft fractures. We retrospectively evaluated 128 cases with humeral shaft fractures that were treated with MIPO technique from March 2005 to August 2008. All the patients were followed up by routine radiological imaging and clinical examinations. Constant-Murley score and HSS elbow joint score were used to evaluate the treatment outcome. The average duration of the surgery was 60 min (range 40-95 min) without blood transfusion. All fractures healed without infection. All cases recovered carrying angle except four cases with 10°-15° cubitus varus. After the average follow-up of 23 (13-38) months, satisfactory function was achieved according to Constant-Murley score and HSS elbow joint score. Constant-Murley score was 80 on average (range 68-91). According to HSS elbow joint score, there were 123 cases of excellent clinical outcome and five cases of effective outcome. It seems to be a safe and effective method for managing humeral shaft fractures with MIPO technique.

  1. Ipsilateral femur and tibia fractures in pediatric patients: A systematic review

    PubMed Central

    Anari, Jason B; Neuwirth, Alexander L; Horn, B David; Baldwin, Keith D

    2017-01-01

    AIM To better understand how pediatric floating knee injuries are managed after the wide spread use of new orthopaedic technology. METHODS We searched EMBASE, COCHRANE and MEDLINE computerized literature databases from the earliest date available in the databases to February 2017 using the following search term including variants and pleural counterparts: Pediatric floating knee. All studies were thoroughly reviewed by multiple authors. Reference lists from all articles were scrutinized to identify any additional studies of interest. A final database of individual patients was assembled from the literature. Univariate and multivariate statistical tests were applied to the assembled database to assess differences in outcomes. RESULTS The English language literature contains series with a total of 97 pediatric patients who sustained floating knee injuries. Patients averaged 9.3 years of age and were mostly male (73). Approximately 25% of the fractures were open injuries, more tibia (27) than femur (10). Over 75% of the fractures of both the tibia and the femur involved the diaphysis. More than half (52) of the patients were treated non-operatively for both fractures. As a sequela of the injury 32 (33%) patients were left with a limb length discrepancy, 24 (25%) patients had lengthening of the injured limb at follow up, while 8 (8%) had shortening of the affected limb. Infection developed in 9 patients and 3 had premature physeal closure. Younger patients were more likely to be treated non-operatively (P < 0.001) and patients treated with operative intervention had statistically significant shorter hospital length of stays (P = 0.001). CONCLUSION Given the predominance of non-operative management in published studies, the available literature is not clinically relevant since the popularization of internal fixation for pediatric long-bone fractures PMID:28875130

  2. Ipsilateral femur and tibia fractures in pediatric patients: A systematic review.

    PubMed

    Anari, Jason B; Neuwirth, Alexander L; Horn, B David; Baldwin, Keith D

    2017-08-18

    To better understand how pediatric floating knee injuries are managed after the wide spread use of new orthopaedic technology. We searched EMBASE, COCHRANE and MEDLINE computerized literature databases from the earliest date available in the databases to February 2017 using the following search term including variants and pleural counterparts: Pediatric floating knee. All studies were thoroughly reviewed by multiple authors. Reference lists from all articles were scrutinized to identify any additional studies of interest. A final database of individual patients was assembled from the literature. Univariate and multivariate statistical tests were applied to the assembled database to assess differences in outcomes. The English language literature contains series with a total of 97 pediatric patients who sustained floating knee injuries. Patients averaged 9.3 years of age and were mostly male (73). Approximately 25% of the fractures were open injuries, more tibia (27) than femur (10). Over 75% of the fractures of both the tibia and the femur involved the diaphysis. More than half (52) of the patients were treated non-operatively for both fractures. As a sequela of the injury 32 (33%) patients were left with a limb length discrepancy, 24 (25%) patients had lengthening of the injured limb at follow up, while 8 (8%) had shortening of the affected limb. Infection developed in 9 patients and 3 had premature physeal closure. Younger patients were more likely to be treated non-operatively ( P < 0.001) and patients treated with operative intervention had statistically significant shorter hospital length of stays ( P = 0.001). Given the predominance of non-operative management in published studies, the available literature is not clinically relevant since the popularization of internal fixation for pediatric long-bone fractures.

  3. The Relationship Between Fractures and DXA Measures of BMD in the Distal Femur of Children and Adolescents With Cerebral Palsy or Muscular Dystrophy

    PubMed Central

    Henderson, Richard C; Berglund, Lisa M; May, Ryan; Zemel, Babette S; Grossberg, Richard I; Johnson, Julie; Plotkin, Horacio; Stevenson, Richard D; Szalay, Elizabeth; Wong, Brenda; Kecskemethy, Heidi H; Harcke, H Theodore

    2010-01-01

    Children with limited or no ability to ambulate frequently sustain fragility fractures. Joint contractures, scoliosis, hip dysplasia, and metallic implants often prevent reliable measures of bone mineral density (BMD) in the proximal femur and lumbar spine, where BMD is commonly measured. Further, the relevance of lumbar spine BMD to fracture risk in this population is questionable. In an effort to obtain bone density measures that are both technically feasible and clinically relevant, a technique was developed involving dual-energy X-ray absorptiometry (DXA) measures of the distal femur projected in the lateral plane. The purpose of this study is to test the hypothesis that these new measures of BMD correlate with fractures in children with limited or no ability to ambulate. The relationship between distal femur BMD Z-scores and fracture history was assessed in a cross-sectional study of 619 children aged 6 to 18 years with muscular dystrophy or moderate to severe cerebral palsy compiled from eight centers. There was a strong correlation between fracture history and BMD Z-scores in the distal femur; 35% to 42% of those with BMD Z-scores less than −5 had fractured compared with 13% to 15% of those with BMD Z-scores greater than −1. Risk ratios were 1.06 to 1.15 (95% confidence interval 1.04–1.22), meaning a 6% to 15% increased risk of fracture with each 1.0 decrease in BMD Z-score. In clinical practice, DXA measure of BMD in the distal femur is the technique of choice for the assessment of children with impaired mobility. © 2010 American Society for Bone and Mineral Research PMID:19821773

  4. COMplex Fracture Orthopedic Rehabilitation (COMFORT) - Real-time visual biofeedback on weight bearing versus standard training methods in the treatment of proximal femur fractures in the elderly: study protocol for a multicenter randomized controlled trial.

    PubMed

    Raaben, Marco; Redzwan, Syaiful; Augustine, Robin; Blokhuis, Taco Johan

    2018-04-12

    Proximal femur fractures are a common injury after low energy trauma in the elderly. Most rehabilitation programs are based on restoring mobility and early resumption of weight-bearing. However, therapy compliance is low in patients following lower extremity fractures. Moreover, little is known about the relevance of gait parameters and how to steer the rehabilitation after proximal femur fractures in the elderly. Therefore, the aim of this prospective, randomized controlled trial is to gain insight in gait parameters and evaluate if real-time visual biofeedback can improve therapy compliance after proximal femur fractures in the elderly. This is a two-arm, parallel-design, prospective, randomized controlled trial. Inclusion criteria are age ≥ 60 years, a proximal femur fracture following low energy trauma, and unrestricted-weight bearing. Exclusion criteria are cognitive impairment and limited mobility before trauma. Participants are randomized into either the control group, which receives care as usual, or the intervention group, which receives real-time visual biofeedback about weight-bearing during gait in addition to care as usual. Spatiotemporal gait parameters will be measured in 94 participants per group during a 30-m walk with an ambulatory biofeedback system (SensiStep). The progress of rehabilitation will be evaluated by the primary outcome parameters maximum peak load and step duration in relation to the discharge date. Secondary outcome parameters include other spatiotemporal gait parameters in relation to discharge date. Furthermore, the gait parameters will be related to three validated clinical tests: Elderly Mobility Scale; Functional Ambulation Categories; and Visual Analogue Scale. The primary hypothesis is that participants in the intervention group will show improved and faster rehabilitation compared to the control group. The first aim of this multicenter trial is to investigate the normal gait patterns after proximal femur fractures in

  5. Elastic nailing of tibia shaft fractures in young children up to 10 years of age.

    PubMed

    Heo, Jeong; Oh, Chang-Wug; Park, Kyeong-Hyeon; Kim, Joon-Woo; Kim, Hee-June; Lee, Jong-Chul; Park, Il-Hyung

    2016-04-01

    Although tibia shaft fractures in children usually have satisfactory results after closed reduction and casting, there are several surgical indications, including associated fractures and soft tissue injuries such as open fractures. Titanium elastic nails (TENs) are often used for pediatric tibia fractures, and have the advantage of preserving the open physis. However, complications such as delayed union or nonunion are not uncommon in older children or open fractures. In the present study, we evaluated children up to 10 years of age with closed or open tibial shaft fractures treated with elastic nailing technique. A total of 16 tibia shaft fractures treated by elastic nailing from 2001 to 2013 were reviewed. The mean patient age at operation was 7 years (range: 5-10 years). Thirteen of 16 cases were open fractures (grade I: 4, grade II: 6, grade IIIA: 3 cases); the other cases had associated fractures that necessitated operative treatments. Closed, antegrade intramedullary nailing was used to insert two nails through the proximal tibial metaphysis. All patients were followed up for at least one year after the injury. Outcomes were evaluated using modified Flynn's criteria, including union, alignment, leg length discrepancies, and complications. All fractures achieved union a mean of 16.1 weeks after surgery (range: 11-26 weeks). No patient reported knee pain or experienced any loss of knee or ankle motion. There was a case of superficial infection in a patient with grade III open fracture. Three patients reported soft tissue discomfort due to prominent TEN tips at the proximal insertion site, which required cutting the tip before union or removing the nail after union. At the last follow-up, there were no angular or rotational deformities over 10° in either the sagittal or coronal planes. With the exception of one case with an overgrowth of 15 mm, no patient showed shortening or overgrowth exceeding 10mm. Among final outcomes, 15 were excellent and 1 was

  6. Acromioclavicular Joint Dislocation with Ipsilateral Mid Third Clavicle, Mid Shaft Humerus and Coracoid Process Fracture - A Case Report.

    PubMed

    Sharma, Naveen; Mandloi, Avinash; Agrawal, Ashish; Singh, Shailendra

    2016-01-01

    The clavicle, humerus and acromioclavicular (AC) joint separately are very commonly involved in traumatic injuries around the shoulder. Acromioclavicular joint dislocation with distal clavicle fracture is a well recognized entity in clinical practice. AC joint dislocation with mid shaft clavicle fracture is uncommon and only few cases have been reported in literature. However, to the best of our knowledge, this is the first case report to describe an acromioclavicular dislocation with ipsilateral mid shaft clavicle, mid shaft humerus and coracoid process fracture. Fractures of the humerus and clavicle along with the acromioclavicular joint dislocation were fixed at the same setting. A 65-year-old male met with a high velocity road traffic accident. Plain radiographs showed displaced mid third clavicle fracture with acromioclavicular joint dislocation with mid shaft humerus fracture. Surgical fixation was planned for humerus with interlocking nail, clavicle with locking plate and acromioclavicular joint with reconstruction of coracoclavicular ligaments. Intraoperatively, coracoid process was found to have a comminuted fracture. The operative plan had to be changed on table as coracoclavicular fixation was not possible. So acromioclavicular joint fixation was done using tension band wiring and the coracoclavicular ligament was repaired using a 2-0 ethibond. The comminuted coracoid fracture was managed conservatively. K wires were removed at 6 weeks. Early mobilization was started. In acromioclavicular joint injuries, clavicle must be evaluated for any injury. Although it is more commonly associated with distal clavicle fractures, it can be associated with middle third clavicle fractures. As plain radiographs, AP view are most of the times insufficient for viewing integrity of coracoid process, either special views like Stryker notch or CT scan may help in diagnosing such concealed injuries. When associated with fractures of the humerus and clavicle, anatomical

  7. Assessment of Outcomes of Treatment of Fractures of Distal Femur with a Locking Plate Taking into Account Factors Influencing the Result.

    PubMed

    Pakuła, Grzegorz; Kwiatkowski, Krzysztof; Kuczmera, Piotr; Fudalej, Piotr

    2015-10-01

    The aim of this paper is to evaluate the results of treatment of distal femoral fractures (DFF) fixed with locking plates and analysis of factors that influence the final outcome. The patients were treated at the Department of Traumatology and Orthopedics, Military Medical Institute in Warsaw, and the Department of Orthopedics and Traumatology, 4th Military Research Hospital in Wroclaw. We analysed 39 patients with 42 fractures of the distal femur. Treatment results were analysed using the KOOS and KSS scales. Factors influencing the outcome were also investigated. Statistical analysis was performed using STATISTICA v. 10. Mean KOOS scores indicate a predominance of poor outcomes, while mean KSS scores indicate good outcomes. Treatment outcomes were significantly influenced by pain and limited mobility. 1. Subjective evaluation of treatment of fractures of the distal femur using the KOOS scale per form edworse than a clinical evaluation using the KSS. 2. Post-operative management should emphasise pain relief and restoration of the performance of the treated lower limb to ensure good mobility without crutches. 3. Despite the use of modern operational methods of fracture fixation, treatment of distal femur fractures is still a challenge.

  8. Paediatric femur fractures at the emergency department: accidental or not?

    PubMed Central

    Vrolijk-Bosschaart, Thekla F; Bakx, Roel; Van Rijn, Rick R.

    2016-01-01

    Only a small proportion of all paediatric fractures is caused by child abuse or neglect, especially in highly prevalent long bone fractures. It can be difficult to differentiate abusive fractures from non-abusive fractures. This article focuses on femoral fractures in young children. Based on three cases, this article presents a forensic evidence-based approach to differentiate between accidental and non-accidental causes of femoral fractures. We describe three cases of young children who were presented to the emergency department because of a suspected femur fracture. Although in all cases, the fracture had a similar location and appearance, the clinical history and developmental stage of the child led to three different conclusions. In the first two cases, an accidental mechanism was a plausible conclusion, although in the second case, neglect of parental supervision was the cause for concern. In the third case, a non-accidental injury was diagnosed and appropriate legal prosecution followed. Any doctor treating children should always be aware of the possibility of child abuse and neglect in children with injuries, especially in young and non-mobile children presenting with an unknown trauma mechanism. If a suspicion of child abuse or neglect arises, a thorough diagnostic work-up should be performed, including a full skeletal survey according to the guidelines of the Royal College of Radiologists and the Royal College of Paediatrics and Child Health. In order to make a good assessment, the radiologist reviewing the skeletal survey needs access to all relevant clinical and social information. PMID:26642309

  9. Radiographic outcomes of single versus dual plate fixation of acute mid-shaft clavicle fractures.

    PubMed

    Chen, Xiaobin; Shannon, Steven F; Torchia, Michael; Schoch, Bradley

    2017-06-01

    The clavicle exhibits considerable movement in three planes making rigid fixation challenging. The addition of a second plate may be considered to improve fixation rigidity, but risks compromising the blood supply to the fracture site. The purpose of this study is to assess if extraperiosteal dual plate fixation increases the rate of non-union, reoperation, and complications at 1 year for surgically treated acute mid-shaft clavicle fractures. Between June 1998 and June 2013, surgically treated mid-shaft clavicle fractures undergoing open reduction internal fixation within 4 weeks of injury were retrospectively reviewed. Patients undergoing single plate fixation were compared to dual plate fixation. Patients were followed for a minimum of 1 year. Charts were reviewed to assess union rates, reoperation, and complications. One hundred and sixty-three clavicles (125 single plates, 34 dual plates) were evaluated. All patients (100%) in dual plating group and one hundred and fourteen (91%) in single plating group obtained bony union by 1 year (p = 0.13). Six patients (4.8%) experienced a non-union in the single plating cohort compared to the dual plating cohort who had a 100% union rate. Seven patients required reoperation in the single plate cohort due to implant failure (N = 4), infection (N = 2), and non-union (N = 1). This limited series of patients demonstrates dual plate fixation is a reliable option for acute mid-shaft clavicle fractures, with excellent union rates and low complication rates. Compared to single plate fixation, no significant differences in outcomes were identified. In the case of more complex fracture patterns, application of a second extraperiosteal plate may be utilized without compromising healing or increasing complication rates.

  10. Principles of management and results of treating the fractured femur during and after total hip arthroplasty.

    PubMed

    Greidanus, Nelson V; Mitchell, Philip A; Masri, Bassam A; Garbuz, Donald S; Duncan, Clive P

    2003-01-01

    The management of fractures of the femur during and after total hip arthroplasty can be difficult, and treatment can be fraught with complications. The ideal scenario would be one in which these fractures are prevented. It is important that the surgeon has a through understanding of the principles of managing these fractures and has access to a variety of fixation and prosthetic devices and allograft bone when necessary in order to provide the best treatment. Because periprosthetic fractures range from the very simple (requiring no surgical intervention) to the complex (requiring major revision), a classification system of these fractures aids in understanding both the principles of management and results of treatment.

  11. Ball-joint versus single monolateral external fixators for definitive treatment of tibial shaft fractures.

    PubMed

    Beltsios, Michail; Mavrogenis, Andreas F; Savvidou, Olga D; Karamanis, Eirineos; Kokkalis, Zinon T; Papagelopoulos, Panayiotis J

    2014-07-01

    To compare modular monolateral external fixators with single monolateral external fixators for the treatment of open and complex tibial shaft fractures, to determine the optimal construct for fracture union. A total of 223 tibial shaft fractures in 212 patients were treated with a monolateral external fixator from 2005 to 2011; 112 fractures were treated with a modular external fixator with ball-joints (group A), and 111 fractures were treated with a single external fixator without ball-joints (group B). The mean follow-up was 2.9 years. We retrospectively evaluated the operative time for fracture reduction with the external fixator, pain and range of motion of the knee and ankle joints, time to union, rate of malunion, reoperations and revisions of the external fixators, and complications. The time for fracture reduction was statistically higher in group B; the rate of union was statistically higher in group B; the rate of nonunion was statistically higher in group A; the mean time to union was statistically higher in group A; the rate of reoperations was statistically higher in group A; and the rate of revision of the external fixator was statistically higher in group A. Pain, range of motion of the knee and ankle joints, rates of delayed union, malunion and complications were similar. Although modular external fixators are associated with faster intraoperative fracture reduction with the external fixator, single external fixators are associated with significantly better rates of union and reoperations; the rates of delayed union, malunion and complications are similar.

  12. Can PET-CT imaging and radiokinetic analyses provide useful clinical information on atypical femoral shaft fracture in osteoporotic patients?

    PubMed

    Chesnut, C Haile; Chesnut, Charles H

    2012-03-01

    Atypical femoral shaft fractures are associated with the extended usage of nitrogen-containing bisphosphonates as therapy for osteoporosis. For such fractures, the positron emission tomography (PET) procedure, coupled with computerized tomography (CT), provides a potential imaging modality for defining aspects of the pathogenesis, site specificity, and possible prodromal abnormalities prior to fracture. PET-CT may assess the radiokinetic variables K1 (a putative marker for skeletal blood flow) and Ki (a putative marker for skeletal bone formation), and when combined with PET imaging modalities and CT skeletal site localization, may define the site of such radiokinetic findings. Further studies into the clinical usage of PET-CT in patients with atypical femoral shaft fractures are warranted.

  13. Early Comparative Outcomes of Carbon Fiber Reinforced Polymer Plate in the Fixation of Distal Femur Fractures.

    PubMed

    Mitchell, Phillip M; Lee, Adam K; Collinge, Cory A; Ziran, Bruce H; Hartley, Kate G; Jahangir, A Alex

    2018-05-16

    To evaluate the early clinical results of distal femur fractures treated with carbon fiber reinforced - polyetheretherketone (CFR-PEEK) plates compared to stainless steel (SS) lateral locking plates. Retrospective comparative cohort study SETTING:: ACS Level I trauma center. Twenty-two patients (11 SS, 11 CFR-PEEK) with closed distal femur fractures treated by a single surgeon over a 6-year period. Nonunion, hardware failure, reoperation, time to full weight bearing, and time ` union were assessed. The CFR-PEEK cohort was on average older (71 vs. 57 years, p=0.03) and more likely to have diabetes (p=0.02). Nonunion was diagnosed in 4/11 (36%) patients in the SS group and 1/11 (9%) patients in the CFR-PEEK group (p=0.12). Hardware failure occurred in two SS patients (18%) compared to none in the CFR-PEEK group (p=0.14). Time to full weight bearing was similar between groups occurring at 9.9 weeks and 12.4 weeks in the CFR-PEEK and SS groups, respectively (p=0.23). Time to radiographic union averaged 12.4 weeks in the SS group and 18.7 weeks in the CFR-PEEK group (p=0.26). There were 4 reoperations in the SS group and one in the CFR-PEEK group (p=0.12). CFR-PEEK plates show encouraging short-term results in the treatment of distal femur fractures with a comparable nonunion, reoperation, and hardware failure rates to those treated with SS plates. This data suggests CFR-PEEK plates may be a viable alternative to SS plates in fixation of these fractures. Level III.

  14. Patient-specific finite element estimated femur strength as a predictor of the risk of hip fracture: the effect of methodological determinants.

    PubMed

    Qasim, M; Farinella, G; Zhang, J; Li, X; Yang, L; Eastell, R; Viceconti, M

    2016-09-01

    A finite element modelling pipeline was adopted to predict femur strength in a retrospective cohort of 100 women. The effects of the imaging protocol and the meshing technique on the ability of the femur strength to classify the fracture and the control groups were analysed. The clinical standard to estimate the risk of osteoporotic hip fracture is based on the areal bone mineral density (aBMD). A few retrospective studies have concluded that finite element (FE)-based femoral strength is a better classifier of fracture and control groups than the aBMD, while others could not find significant differences. We investigated the effect of the imaging protocol and of the FE modelling techniques on the discriminatory power of femoral strength. A retrospective cohort of 100 post-menopausal women (50 with hip fracture, 50 controls) was examined. Each subject received a dual-energy absorptiometry (DXA) exam and a computed tomography (CT) scan of the proximal femur region. Each case was modelled a number of times, using different modelling pipelines, and the results were compared in terms of accuracy in discriminating the fracture and the control cases. The baseline pipeline involved local anatomical orientation and mesh morphing. Revised pipelines involved global anatomical orientation using a full-femur atlas registration and an optimised meshing algorithm. Minimum physiological (MPhyS) and pathological (MPatS) strengths were estimated for each subject. Area under the receiver operating characteristic (ROC) curve (AUC) was calculated to compare the ability of MPhyS, MPatS and aBMD to classify the control and the cases. Differences in the modelling protocol were found to considerably affect the accuracy of the FE predictors. For the most optimised protocol, logistic regression showed aBMDNeck, MPhyS and MPatS to be significantly associated with the facture status, with AUC of 0.75, 0.75 and 0.79, respectively. The study emphasized the necessity of modelling the whole femur

  15. Delay in weight bearing in surgically treated tibial shaft fractures is associated with impaired healing: a cohort analysis of 166 tibial fractures.

    PubMed

    Houben, I B; Raaben, M; Van Basten Batenburg, M; Blokhuis, T J

    2018-04-09

    The relation between timing of weight bearing after a fracture and the healing outcome is yet to be established, thereby limiting the implementation of a possibly beneficial effect for our patients. The current study was undertaken to determine the effect of timing of weight bearing after a surgically treated tibial shaft fracture. Surgically treated diaphyseal tibial fractures were retrospectively studied between 2007 and 2015. The timing of initial weight bearing (IWB) was analysed as a predictor for impaired healing in a multivariate regression. Totally, 166 diaphyseal tibial fractures were included, 86 cases with impaired healing and 80 with normal healing. The mean age was 38.7 years (range 16-89). The mean time until IWB was significantly shorter in the normal fracture healing group (2.6 vs 7.4 weeks, p < 0.001). Correlation analysis yielded four possible confounders: infection requiring surgical intervention, fracture type, fasciotomy and open fractures. Logistic regression identified IWB as an independent predictor for impaired healing with an odds ratio of 1.13 per week delay (95% CI 1.03-1.25). Delay in initial weight bearing is independently associated with impaired fracture healing in surgically treated tibial shaft fractures. Unlike other factors such as fracture type or soft tissue condition, early resumption of weight bearing can be influenced by the treating physician and this factor therefore has a direct clinical relevance. This study indicates that early resumption of weight bearing should be the treatment goal in fracture fixation. 3b.

  16. Femoral fracture repair using a locking plate technique in an adult captive polar bear (Ursus maritimus).

    PubMed

    Zimmerman, Dawn M; Dew, Terry; Douglass, Michael; Perez, Edward

    2010-02-01

    To report successful femoral fracture repair in a polar bear. Case report. Female polar bear (Ursus maritimus) 5 years and approximately 250 kg. A closed, complete, comminuted fracture of the distal midshaft femur was successfully reduced and stabilized using a compression plating technique with 2 specialized human femur plates offering axial, rotational, and bending support, and allowing the bone to share loads with the implant. Postoperative radiographs were obtained at 11.5 weeks, 11 months, and 24 months. Bone healing characterized by marked periosteal reaction was evident at 11 months with extensive remodeling evident at 24 months. No complications were noted. Distal mid shaft femoral fracture was reduced, stabilized, and healed in an adult polar bear with a locking plate technique using 2 plates. Previously, femoral fractures in polar bears were considered irreparable. Use of 2 plates applied with a locking plate technique can result in successful fracture repair despite large body weight and inability to restrict postoperative activity.

  17. Comparison between open plating versus minimally invasive plate osteosynthesis for acute displaced clavicular shaft fractures.

    PubMed

    Sohn, Hoon-Sang; Kim, Won Ju; Shon, Min Soo

    2015-08-01

    Current literatures describe good clinical outcomes of acute displaced fracture of clavicle treated with minimally invasive plate osteosynthesis (MIPO). But, there are little comparative data of the outcomes between open plating and MIPO techniques. We compared the outcomes of open plating and MIPO for treatment of acute displaced clavicular shaft fractures. The author performed a retrospective review on a consecutive series of patients with clavicular shaft fracture who underwent open plating or MIPO. Fourteen patients were treated with open plating with interfragmentary screw fixation, and 19 were treated with the MIPO technique without exposing a fracture site itself. A superior plating method was applied to both groups. Patient demographics, clinical outcomes using Constant score and University of California Los Angeles (UCLA) shoulder score, operation time, union rate, complications, and radiographic evaluation were evaluated. There were no statistically significant differences in the demographic data, including patient's variables (age, gender, involved side, smoking, alcohol, and diabetic status) and fracture characteristics (trauma mechanism, distribution of fracture type, presence of polytrauma, and time from trauma to surgery) between the two groups. Mean operation time was 87.5 min in open plating and 77.2 min in MIPO (p=0.129). The mean time to union was 15.7 weeks in patients who underwent open plating and 16.8 weeks in patients who underwent MIPO (p=0.427). Although there was no significant difference, nonunion developed 1 case in MIPO while none was in open plating. Four patients in open plating had skin numbness (none in MIPO, p=0.024). There was no significant difference in the Constant score and UCLA score of the two surgical methods. This study showed that both open plating with interfragmentary screw fixation (Open plating) and minimally invasive plate osteosynthesis (MIPO) are equally effective and safe treatment methods for acute displaced

  18. Dynamic Fixation of Humeral Shaft Fractures Using Active Locking Plates: A Prospective Observational Study.

    PubMed

    Madey, Steven M; Tsai, Stanley; Fitzpatrick, Daniel C; Earley, Kathleen; Lutsch, Michael; Bottlang, Michael

    2017-01-01

    Rigid locked plating constructs can suppress fracture healing by inhibiting interfragmentary motion required to stimulate natural bone healing by callus formation. Dynamic fixation with active locking plates reduces construct stiffness, enables controlled interfragmentary motion, and has been shown to induce faster and stronger bone healing in vivo compared to rigid locking plates. This prospective observational study represents the first clinical use of active locking plates. It documents our early clinical experience with active plates for stabilization of humeral shaft fractures to assess their durability and understand potential complications. Eleven consecutive patients with humeral shaft fractures (AO/OTA types 12 A-C) were prospectively enrolled at a level I and a level II trauma center. Fractures were stabilized by using active locking plates without supplemental bone graft or bone morphogenic proteins. The screw holes of active locking plates are elastically suspended in elastomer envelopes inside the plate, enabling up to 1.5 mm of controlled interfragmentary motion. Progression of fracture healing and integrity of implant fixation was assessed radiographically at 3, 6, 12, and 24 weeks post surgery. Patient-reported functional outcome measures were obtained at 6, 12, and 24 weeks post surgery. The primary endpoint of this study was plate durability in absence of plate bending or breakage, or failure of the elastically suspended locking hole mechanism. Secondary endpoints included fracture healing, complications requiring revision surgery, and functional outcome scores. The eleven patients had six simple AO/ OTA type 12A fractures, three wedge type 12B fractures, and two comminuted type 12C fracture, including one open fracture. All active locking plates endured the 6-month loading period without any signs of fatigue or failure. Ten of eleven fractures healed at 10.9 ± 5.2 weeks, as evident by bridging callus and pain-free function. One fracture required

  19. Ketorolac Administered in the Recovery Room for Acute Pain Management Does Not Affect Healing Rates of Femoral and Tibial Fractures.

    PubMed

    Donohue, David; Sanders, Drew; Serrano-Riera, Rafa; Jordan, Charles; Gaskins, Roger; Sanders, Roy; Sagi, H Claude

    2016-09-01

    To determine whether ketorolac administered in the immediate perioperative period affects the rate of nonunion in femoral and tibial shaft fractures. Retrospective comparative study. Single Institution, Academic Level 1 Trauma Center. Three hundred and thirteen skeletally mature patients with 137 femoral shaft (OTA 32) and 191 tibial shaft (OTA 42) fractures treated with intramedullary rod fixation. Eighty patients with 33 femoral shaft and 52 tibial shaft fractures were administered ketorolac within the first 24 hours after surgery (group 1-study group). Two-hundred thirty-three patients with 104 femoral shaft and 139 tibial shaft fractures were not (group 2-control group). Rate of reoperation for repair of a nonunion and time to union. Average time to union of the femur was 147 days for group 1 and 159 days for group 2 (P = 0.57). Average time to union of the tibia was 175 days for group 1 and 175 days for group 2 (P = 0.57). There were 3 femoral nonunions (9%) in group 1 and eleven femoral nonunions (11.6%) in group 2 (P = 1.00). There were 3 tibial nonunions (5.8%) in group 1 and 17 tibial nonunions (12.2%) in group 2 (P = 0.29). The average dose of ketorolac for patients who healed their fracture was 85 mg, whereas it was 50 mg for those who did not (P = 0.27). All patients with a nonunion in the study group were current smokers. Ketorolac administered in the first 24 hours after fracture repair for acute pain management does not seem to have a negative impact on time to healing or incidence of nonunion for femoral or tibial shaft fractures. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  20. Minimizing the complications of intramedullary nailing for distal third tibial shaft and metaphyseal fractures

    PubMed Central

    Yaligod, Vishwanath; Rudrappa, Girish H.; Nagendra, Srinivas; Shivanna, Umesh M.

    2013-01-01

    Background The complications of intramedullary nailing of distal third tibial shaft and metaphyseal fractures have a direct impact on ankle and hind foot function. Methods We retrospectively evaluated 28 patients. Unreamed nail was negotiated across the well reduced fracture till subchondral bone and fixed with 2 to 3 distal locking screws in different planes. Results Fracture union rate was 85%. Three out of 28 patients had malalignment. Mean ankle, hindfoot functional score was 85. Conclusion Complications can be minimized by impacting the unreamed nail till the subchondral bone while maintaining the fracture well reduced and by using multiple distal locking screws in different planes. PMID:24719527

  1. Fracture prevention by prophylactic femoroplasty of the proximal femur--metallic compared with cemented augmentation.

    PubMed

    Springorum, Hans-Robert; Gebauer, Matthias; Mehrl, Alexander; Stark, Olaf; Craiovan, Benjamin; Püschel, Klaus; Amling, Michael; Grifka, Joachim; Beckmann, Johannes

    2014-07-01

    To compare 2 different femoral neck augmentation techniques at improving the mechanical strength of the femoral neck. Twenty pairs of human cadaveric femora were randomly divided into 2 groups. In 1 group, the femora were augmented with a steel spiral; the other group with the cemented technique. The untreated contralateral side served as an intraindividual control. Fracture strength was evaluated using an established biomechanical testing scenario mimicking a fall on the greater trochanter (Hayes fall). The peak load to failure was significantly higher in the steel spiral group (P = 0.0024) and in the cemented group (P = 0.001) compared with the intraindividual controls. The peak load to failure showed a median of 3167 N (1825-5230 N) in the spiral group and 2485 N (1066-4395 N) in the spiral control group. The peak load to failure in the cemented group was 3698 N (SD ± 1249 N) compared with 2763 N (SD ± 1335 N) in the cement control group. Furthermore, fracture displacement was clearly reduced in the steel spiral group. Femoral augmentations using steel spirals or cement-based femoroplasty are technically feasible procedures. Our results demonstrate that a prophylactic reinforced proximal femur has higher strength when compared with the untreated contralateral limb. Prophylactic augmentation has potential to become an auxiliary treatment option to protect the osteoporotic proximal femur against fracture.

  2. Time intervals in the treatment of fractured femurs as indicators of the quality of trauma systems.

    PubMed

    Matityahu, Amir; Elliott, Iain; Marmor, Meir; Caldwell, Amber; Coughlin, Richard; Gosselin, Richard A

    2014-01-01

    To investigate the use of time intervals in the treatment of fractured femurs as indicators of the quality of trauma systems. Time intervals from injury to admission, admission to surgery and surgery to discharge for patients with isolated femur fractures in four low- and middle-income countries were compared with the corresponding values from one German hospital, an Israeli hospital and the National Trauma Data Bank of the United States of America by means of Student's t-tests. The correlations between the time intervals recorded in a country and that country's expenditure on health and gross domestic product (GDP) were also evaluated using Pearson's product moment correlation coefficient. Relative to patients from high-income countries, those from low- and middle-income countries were significantly more likely to be male and to have been treated by open femoral nailing, and their intervals from injury to admission, admission to surgery and surgery to discharge were significantly longer. Strong negative correlations were detected between the interval from injury to admission and government expenditure on health, and between the interval from admission to surgery and the per capita values for total expenditure on health, government expenditure on health and GDP. Strong positive correlations were detected between the interval from surgery to discharge and general government expenditure on health. The time intervals for the treatment of femur fractures are relatively long in low- and middle-income countries, can easily be measured, and are highly correlated with accessible and quantifiable country data on health and economics.

  3. Dynamic locked plating for fixation of distal femur fractures using near- cortical over-drilling: Preliminary results of a prospective observational study.

    PubMed

    Galal, Sherif

    2017-01-01

    Nonunion after locked plating of distal femur fractures is not uncommon. Authors wanted to assess if "Dynamic" locked plating using near-cortex over-Drilling technique would provide a mechanical environment the promotes callus formation, thereby avoiding non-union encountered when applying locked plates with the conventional method. This study was conducted at an academic Level 1 Trauma Center. This is a prospective study conducted from November 2015 to November 2016. Follow-up was 10 months on average (ranging from 8 to 12 months). The study included 20 patients with 20 fractures (13 males, 7 females). The average patients' age was 41.2 years (18-64 years). According to the Müller AO classification of distal femur fractures (33A-C) there were 15 cases with extra-articular fractures (AO 33A), 5 patients with intra-articular fractures (AO 33C). Dynamic Locked plating using near-cortical over-drilling technique was done for all patients. Two blinded observers assessed callus score on 6-week radiographs using a 4-point ordinal scale. A 2-tailed t -test. Two-way mixed intra-class correlation testing was performed to determine reliability of the callus measurements by the 2 observers. All patients achieved union, time to union was 13.4 weeks on average (range form 8-24 weeks). Delayed union was observed in 2 patients. The average callus score for fractures was 1.8 (SD 0.6). All fractures united in alignment except 1 fracture which united in valgus malalignment, the deformity was appreciated in the postoperative radiographs. No wound related complications, no loss of reduction, no catastrophic implant failure or screw breakage were detected. Dynamic locked plating using near-cortex over-drilling is a simple technique that uses standard locked plates that promotes callus formation when used for fixing distal femur fractures.

  4. Mechanical evaluation of hip pads to protect against fracture of elderly femurs in falls.

    PubMed

    Tadano, Shigeru; Nakatsuchi, Hiroki; Goto, Naoko; Fujisaki, Kazuhiro; Nakatsuchi, Yukio

    2011-01-01

    Hip fracture in the aged easily occurs by falls and may cause these persons to become bedridden. Hip pads are effective in protecting hip fracture as they directly deflect and absorb the impact forces by falls. It is necessary for the material and the structure of hip pads to be designed to realize both high impact absorption and compliance (comfort during wearing). In this report, an impact testing system was developed to test the impact absorbing performance of hip pad with air cushions designed by the research group. The impact absorbing performance was evaluated by the impact load, collision time, and maximum load. To confirm the effectiveness in protecting against hip fracture, an impact force was applied to the greater trochanter of the human femur and the degree of fracture was measured by X-ray examination. As a result, the hip pad with air cushions had a high impact absorbing performance and was sufficiently effective to protect against hip fracture.

  5. Humerus shaft fracture associated with traumatic radial nerve palsy: An international survey among orthopedic trauma surgeons from Latin America and Asia/Pacific.

    PubMed

    Giordano, Vincenzo; Belangero, William; Pires, Robinson Esteves; Labronici, Pedro José

    2017-01-01

    The purpose of this article is to explore the real-life practice of clinical management of humeral shaft fracture associated with traumatic radial nerve palsy among orthopedic trauma surgeons. Two hundred seventy-nine orthopedic surgeons worldwide reviewed 10 real cases of a humeral shaft fracture associated with traumatic radial nerve palsy answering two questions: (1) What treatment would you choose/recommend: nonoperative or operative? (2) What are the reasons for your decision-making? The survey was developed in an online survey tool. All participants were active members from AOTrauma International. Two hundred sixty-six (95.3%) participants were from Latin America and Asia/Pacific. One hundred sixty-two participants (58.1%) had more than 10 years in practice and 178 (63.8%) of them did trauma as the main area of interest. One hundred fifty-one (54.1%) participants treated less than three humeral shaft fractures a month. Traumatic radial nerve palsy was the main reason (88.4%) for surgeons to recommend surgical treatment. Open reduction and internal fixation (ORIF) or percutaneous fixation of the fracture associated with acutely explore of radial nerve was the first option in 62.0% of the cases. A combination of morphology and level of the fracture and the presence of the radial nerve palsy was the most suggested reason to surgically treat the humerus fracture. The main isolated factor was the morphology of the fracture. Our survey highlight the tendency for a more aggressive management of any humeral shaft fracture associated with a traumatic radial nerve palsy, with surgeons preferring to use ORIF with acute exploration of the radial nerve. Nonsurgical management was the less chosen option among the 279 respondents. Fracture morphology, level of the fracture, and the presence of the radial nerve palsy were most influential for guiding their treatment.

  6. Sensitivity and specificity of CT- and MRI-scanning in evaluation of occult fracture of the proximal femur.

    PubMed

    Haubro, M; Stougaard, C; Torfing, T; Overgaard, S

    2015-08-01

    To estimate sensitivity and specificity of CT and MRI examinations in patients with fractures of the proximal femur. To determine the interobserver agreement of the modalities among a senior consulting radiologist, a resident in radiology and a resident in orthopaedics surgery. 67 patients (27 males, 40 females, mean age 80.5) seen in the emergency room with hip pain after fall, inability to stand and a primary X-ray without fracture were evaluated with both CT and MRI. The images were analysed by a senior consulting musculoskeletal radiologist, a resident in radiology and a resident in orthopaedic surgery. Sensitivity and specificity were estimated with MRI as the golden standard. Kappa value was used to assess level of agreement in both MRI and CT finding. 15 fractures of the proximal femur were found (7 intertrochanteric-, 3 femoral neck and 5 fractures of the greater trochanter). Two fractures were not identified by CT and four changed fracture location. Among those, three patients underwent surgery. Sensitivity of CT was 0.87; 95% CI [0.60; 0.98]. Kappa for interobserver agreement for CT were 0.46; 95% CI [0.23; 0.76] and 0.67; 95% CI [0.42; 0.90]. For MRI 0.67; 95% CI [0.43; 0.91] and 0.69; 95% CI [0.45; 0.92]. MRI was observed to have a higher diagnostic accuracy than CT in detecting occult fractures of the hip. Interobserver analysis showed high kappa values corresponding substantial agreement in both CT and MRI. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Percutaneous or Open Reduction of Closed Tibial Shaft Fractures During Intramedullary Nailing Does Not Increase Wound Complications, Infection or Nonunion Rates.

    PubMed

    Auston, Darryl A; Meiss, Jordan; Serrano, Rafael; Sellers, Thomas; Carlson, Gregory; Hoggard, Timothy; Beebe, Michael; Quade, Jonathan; Watson, David; Simpson, Robert Bruce; Kistler, Brian; Shah, Anjan; Sanders, Roy; Mir, Hassan R

    2017-04-01

    To compare the incidence of complications (wound, infection, and nonunion) among those patients treated with closed, percutaneous, and open intramedullary nailing for closed tibial shaft fractures. Retrospective review. Multiple trauma centers. Skeletally mature patients with closed tibia fractures amenable to treatment with an intramedullary device. Intramedullary fixation with closed, percutaneous, or open reduction. Superficial wound complication, deep infection, nonunion. A total of 317 tibial shaft fractures in 315 patients were included in the study. Two-hundred fractures in 198 patients were treated with closed reduction, 61 fractures in 61 patients were treated with percutaneous reduction, and 56 fractures in 56 patients were treated with formal open reduction. The superficial wound complication rate was 1% (2/200) for the closed group, 1.6% (1/61) for the percutaneous group, and 3.6% (2/56) for the open group with no statistical difference between the groups (P = 0.179). The deep infection rate was 2% (4/200) for the closed group, 1.6% (1/61) for the percutaneous group, and 7.1% (4/56) for the open group with no significant difference between the groups (P = 0.133). Nonunion rate was 5.0% (10/200) for the closed group, 4.9% (3/61) for the percutaneous group, and 7.1% (4/56) for the open group, with no statistical difference between the groups (P = 0.492). This is the largest reported series of closed tibial shaft fractures nailed with percutaneous and open reduction. Percutaneous or open reduction did not result in increased wound complications, infection, or nonunion rates. Carefully performed percutaneous or open approaches can be safely used in obtaining reduction of difficult tibial shaft fractures treated with intramedullary devices. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  8. Factors affecting length of stay after isolated femoral shaft fractures.

    PubMed

    Pendleton, Albert M; Cannada, Lisa K; Guerrero-Bejarano, Maria

    2007-03-01

    Controlling escalating health care costs is important for hospitals and has far reaching implications for society. Hospital length of stay (LOS) is one of the most reliable predictors of cost after trauma. Our purpose was to establish LOS after isolated femur fractures treated by intramedullary (IM) nail. The trauma registry was queried to identify patients. Patients were excluded if they required assistive ambulatory devices before injury, had chronic/terminal illness or compromised brain function. There were 102 patients with an average age of 27 years. Statistical analysis was completed. The average LOS was 3.9 days. In all, 27 patients stayed longer than 4 days. Reasons included social (7), medical (10), and hospital delays (10). The average time from arrival to surgery was 17 hours. The average time from surgery to physical therapy was 1.3 days. Patients who had surgery more than 24 hours after arrival stayed longer. Patients requiring placement stayed 2.4 days longer until placement was found. Factors the hospital can control to reduce LOS include time to surgery, time for physical therapy evaluation, and radiology delays (for spine clearance radiographs). Physical therapy availability within 24 hours of surgery is important and should include weekends and holidays. Early evaluation of social factors including homelessness or obstacles to independent living may reduce time to find placement. LOS reduction after femur fractures will decrease the cost of trauma to the hospital. In addition, LOS reduction will possibly increase bed availability and minimize the time spent on diversion yielding greater revenues and increasing patient satisfaction.

  9. Enhanced hip fracture management: use of statistical methods and dataset to evaluate a fractured neck of femur fast track pathway-pilot study.

    PubMed

    Gilchrist, Nigel; Dalzell, Kristian; Pearson, Scott; Hooper, Gary; Hoeben, Kit; Hickling, Jeremy; McKie, John; Yi, Ma; Chamberlain, Sandra; McCullough, Caroline; Gutenstein, Marc

    2017-05-12

    The increasing elderly population and subsequent rise in total hip fracture(s) in this group means more effective management strategies are necessary to improve efficiency. We have changed our patient care strategy from the emergency department (ED), acute orthopaedic wards, operating theatre, post-operation and rehabilitation, and called it Fracture Neck of Femur Fast Track Pathway. All clinical data and actions were captured, integrated and displayed on a weekly basis using 'signalfromnoise' (SFN) software. The initial four months analysis of this project showed significant improvement in patient flow within the hospitals. The overall length of stay was reduced by four days. Time in ED was reduced by 30 minutes, and the wait for rehabilitation reduced by three days. Overall time in rehabilitation reduced by 3-7 days depending on facility. On average, fast track patients spent 95 less hours in hospital, resulting in 631 bed days saved in this period, with projected savings of NZD700,000. No adverse effects were seen in mortality, readmission and functional improvement status. Fractured neck of femur has increasing clinical demand in a busy tertiary hospital. Length of stay, co-morbidities and waiting time for theatres are seen as major barriers to treatment for these conditions. Wait for rehabilitation can significantly lengthen hospital stay; also poor communication between the individual hospital management facets of this condition has been an ongoing issue. Lack of instant and available electronic information on this patient group has also been seen as a major barrier to improvement. This paper demonstrates how integration of service components that are involved in fractured neck of femur can be achieved. It also shows how the use of electronic data capture and analysis can give a very quick and easily interpretable data trend that will enable change in practice. This paper indicates that cooperation between health professionals and practitioners can

  10. A case report of a completely displaced stress fracture of the femoral shaft in a middle-aged male athlete - A precursor of things to come?

    PubMed

    Larsen, Peter; Elsoe, Rasmus; Rathleff, Michael S

    2016-05-01

    Displaced stress fractures of the femoral shaft are very uncommon. The proportion of middle-aged and older age groups participating in long-distance running, triathlon and other high intensity sports is increasing. As a consequence stress fracture of the femoral shaft may be on the rise in the future. The patient was 43 years old male caucasian triathlete. The authors met the patient after he was admitted with a displaced femoral shaft fracture. The fracture occurred during running at the national championship in ½ Ironman. The patient reported that his symptoms had gradually developed over the last month before the fracture with pain localized anterior to the thigh. The patient interpreted the symptoms as local muscle damage. A clinical examination was conducted by a physiotherapist and the symptoms were interpreted as a simple muscle injury in the quadriceps. When presented with a patient with non-traumatic, diffuse anterior thigh pain in an individual of this age, who is participating in high-level endurance running; clinicians should consider the possibility that the cause of the symptoms may be a femoral shaft stress fracture. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. [Ender nailing in fractures of the proximal femur. II. Analysis of our cohort].

    PubMed

    Bartonícek, J

    1989-12-01

    The work presents the analysis of the group of 172 patients with the fracture of the proximal femur treated by the technique of Ender nailing between June 1985 and December 1988. The group comprised 45 male (26 per cent) and 127 female (74 per cent) patients. Their average age was 76 years (ranging from 20 to 97 years of age) out of which 75 per cent of patients were older than 70 years and 40 per cent older than 80 years. Indication of Ender nailing in patients under 60 years of age we consider exceptional. In our group we operated on in total 14 patients under 60 years of age (ranging from 20 to 57 years of age) and namely in case of the comminuted type of fracture increased risk of infection or serious total condition. The whole group was operated on by 21 variously experienced surgeons. 147 operations were performed in the general anesthesia and 25 in the epidural one. The fractures of the proximal femur were divided into basicervical--10 (6 per cent), stable pertrochanteric 96 (56 per cent), unstable pertrochanteric--38 (22 per cent), per-subtrochanteric--19 (11 per cent) and subtrochanteric--9 (5 per cent). For the objective evaluation we compared our classification of the fracture of the trochanteric part with these of Evens, Kyle and Jensen. For stable fractures we considered the types I and II according to Kyle, for unstable the type III of Kyle classification. Per-subtrochanteric fractures (Kyle IV) we singled out for their seriousness as a separate group of unstable pertrochanteric fractures. Almost the same spectrum of fractures was in the group of 108 patients in which we evaluated longterm results. The minimum observence period was 3 months the mean period 6.3 months. Almost all patients from this group were followed up until complete healing. The mean duration of operation was 52 minutes, the mean duration of anesthesia was 81 minutes and the duration of X-ray exposure was 2.6 minutes. These data were calculated also for individual types of fractures

  12. Fat embolus in femur fractures: a comparison of two reaming systems.

    PubMed

    Volgas, David A; Burch, Tommy; Stannard, James P; Ellis, Truitt; Bilotta, Jessica; Alonso, Jorge E

    2010-11-01

    To measure the amount of fat presented to the right heart during reaming and nail placement using two different reamer systems. Prospective, randomized clinical trial. University-based Level I Trauma Center. 20 patients with femur fractures. Patients with femur fractures were treated with intramedullary nailing using either reamer-irrigator-aspirator or a conventional reamer. four-chamber trans-esophageal echocardiogram was used to quantify the amount of fat presented to the right atrium. There were 2 female and 18 male patients enrolled, 10 in each group. There was no significant difference (p = 0.10) between reaming systems on the opening reamer, which was expected since both trial limbs used the same opening reamer. However, during the first pass of the reamer, the RIA showed a nearly-significant decrease in the volume of fat in the right atrium (p = 0.06). During passage of the nail, there was a significant difference with Group B having less fat embolus than Group A (p = 0.01). The power of this study is 0.81. The mean ISS was not significantly different between the two groups, nor was the sex, age or race. There was one death from cardiac complications in a patient who showed no fat during any phase of the procedure. This patient had significant mitral and aortic regurgitation pre-operatively. There was one patient with clinical fat embolism syndrome and one patient with a nonunion. There is a statistically significant difference in the amount of fat presented to the lungs using a RIA versus conventional reamer. Copyright © 2010 Elsevier Ltd. All rights reserved.

  13. A Comparison of More and Less Aggressive Bone Debridement Protocols for the Treatment of Open Supracondylar Femur Fractures

    PubMed Central

    Ricci, William M.; Collinge, Cory; Streubel, Philipp N.; McAndrew, Christopher M.; Gardner, Michael J.

    2014-01-01

    Objectives This study compared results of aggressive and nonaggressive debridement protocols for the treatment of high energy open supracondylar femur fractures after the primary procedure, with respect to the requirement for secondary bone grafting procedures, and deep infection. Design Retrospective review Setting Level I and Level II Trauma Centers Patients/Participants Twenty-nine consecutive patients with high grade open (Gustilo Types II and III) supracondylar femur fractures (OTA/AO 33A and C) treated with debridement and locked plating. Intervention Surgeons at two different Level I trauma centers had different debridement protocols for open supracondylar femur fractures. One center used a More Aggressive (MA)protocol in their patients (n=17) that included removal of all devitalized bone and placement of antibiotic cement spacers to fill large segmental defects. The other center used a Less Aggressive (LA) protocol in their patients (n=12) that included debridement of grossly contaminated bone with retention of other bone fragments and no use of antibiotic cement spacers. All other aspects of the treatment protocol at the two centers were similar: definitive fixation with locked plates in all cases; IV antibiotics were used until definitive wound closure; and weight bearing was advanced upon clinical and radiographic evidence of fracture healing. Main Outcome Measurements Healing after the primary procedure, requirement for secondary bone grafting procedures, and the presence of deep infection. Results Demographics were similar between included patients at each center with regard to: age; gender; rate of open fractures; open fracture classification; mechanism; and smoking (p>.05). Patients at the MA center were more often diabetic (p<.05).Cement spacers to fill segmental defects were used more often after MA debridement (35% vs 0%, p<0.006) and more patients had a plan for staged bone grafting after MA debridement (71% vs 8%, p<0.006). Healing after the

  14. A comparison of more and less aggressive bone debridement protocols for the treatment of open supracondylar femur fractures.

    PubMed

    Ricci, William M; Collinge, Cory; Streubel, Philipp N; McAndrew, Christopher M; Gardner, Michael J

    2013-12-01

    This study compared results of aggressive and nonaggressive debridement protocols for the treatment of high-energy, open supracondylar femur fractures after the primary procedure, with respect to the requirement for secondary bone grafting procedures, and deep infection. Retrospective review. Level I and level II trauma centers. Twenty-nine consecutive patients with high-grade, open (Gustilo types II and III) supracondylar femur fractures (OTA/AO 33A and C) treated with debridement and locked plating. Surgeons at 2 different level I trauma centers had different debridement protocols for open supracondylar femur fractures. One center used a more aggressive (MA) protocol in their patients (n = 17) that included removal of all devitalized bone and placement of antibiotic cement spacers to fill large segmental defects. The other center used a less aggressive (LA) protocol in their patients (n = 12) that included debridement of grossly contaminated bone with retention of other bone fragments and no use of antibiotic cement spacers. All other aspects of the treatment protocol at the 2 centers were similar: definitive fixation with locked plates in all cases, IV antibiotics were used until definitive wound closure, and weight bearing was advanced upon clinical and radiographic evidence of fracture healing. Healing after the primary procedure, requirement for secondary bone grafting procedures, and the presence of deep infection. Demographics were similar between included patients at each center with regard to age, gender, rate of open fractures, open fracture classification, mechanism, and smoking (P > 0.05). Patients at the MA center were more often diabetic (P < 0.05). Cement spacers to fill segmental defects were used more often after MA debridement (35% vs. 0%, P < 0.006), and more patients had a plan for staged bone grafting after MA debridement (71% vs. 8%, P < 0.006). Healing after the index fixation procedure occurred more often after LA debridement (92% vs. 35

  15. Treatment of pediatric femoral shaft fractures by stainless steel and titanium elastic nail system: A randomized comparative trial.

    PubMed

    Gyaneshwar, Tank; Nitesh, Rustagi; Sagar, Tomar; Pranav, Kothiyal; Rustagi, Nitesh

    2016-08-01

    Literature suggests that the lower modulus of elasticity of titanium makes it ideal for use in children compared with stainless steel. Better fracture stability was observed in association with titanium nails on torsional and axial compression testing. However, stainless steel nails are stiffer than titanium counterparts, which may provide a rigid construct when fixing paediatric femoral shaft fractures. Complications have been observed more frequently by various researchers when titanium nails are used for fracture fixation in patients with increasing age or weight. The concept of this study was to compare the functional outcome after internal fixation with titanium elastic nail system and stainless steel elastic nail system in paediatric femoral shaft fractures. The study was conducted on 34 patients admitted in the department of orthopaedics, LLRM Medical College & SVBP Hospital, Meerut, India from January 2013 to August 2014. We included patients aged 5-12 years with fracture of the femoral shaft, excluding compound fractures, pathological fractures and other lower limb fractures. Patients were treated by titanium (n=17) or stainless steel (n=17) elastic nail system and followed up for one year. The clinical parameters like range of motion at hip and knee joints, time to full weight bearing on the operated limb and radiological parameters like time to union were compared between two groups. A special note was made of intra- and post-operative complications. Functional outcomes were analysed according to Flynn criteria. Based on the Flynn criteria, 59% of patients had excellent results, 41% had satisfactory results, and no one showed poor results. There was no clinically significant difference between the two groups with respect to time to union and full weight bearing. But the incidence of puncture of the opposite cortex while inserting the nail and trying to advance it through the diaphysis during operation is greatly different. Only one such case was observed

  16. Bisphosphonates and atypical femoral fractures.

    PubMed

    Adler, Robert A

    2016-12-01

    Bisphosphonates are used widely for the treatment of osteoporosis and prevention of fractures. Although generally well tolerated and effective, bisphosphonates (and denosumab, a newer antiresorptive agent) have been associated with unusual fractures of the femoral shaft. New information about the incidence, pathophysiology, and management of atypical femoral fractures (AFFs) are reviewed. Histomorphometric studies have shown variable amounts of bone turnover suppression, but new studies suggest that healing near bone cracks may not occur in patients with AFF. Some studies suggest that hip and femur geometry make certain people more at risk for AFF. In some but not all studies, the risk of AFF appears to be related to duration of treatment. Thus, the benefit/risk ratio needs to be reassessed as bisphosphonate therapy is prolonged. If we can better understand the pathogenesis of AFF, it may be possible to identify those patients at highest risk. In the meantime, clinicians must periodically assess risk for osteoporotic fracture versus risk for AFF in managing patients with osteoporosis.

  17. Comparison of suprapatellar and infrapatellar intramedullary nailing for tibial shaft fractures: a systematic review and meta-analysis.

    PubMed

    Yang, Liqing; Sun, Yuefeng; Li, Ge

    2018-06-14

    Optimal surgical approach for tibial shaft fractures remains controversial. We perform a meta-analysis from randomized controlled trials (RCTs) to compare the clinical efficacy and prognosis between infrapatellar and suprapatellar intramedullary nail in the treatment of tibial shaft fractures. PubMed, OVID, Embase, ScienceDirect, and Web of Science were searched up to December 2017 for comparative RCTs involving infrapatellar and suprapatellar intramedullary nail in the treatment of tibial shaft fractures. Primary outcomes were blood loss, visual analog scale (VAS) score, range of motion, Lysholm knee scores, and fluoroscopy times. Secondary outcomes were length of hospital stay and postoperative complications. We assessed statistical heterogeneity for each outcome with the use of a standard χ 2 test and the I 2 statistic. The meta-analysis was undertaken using Stata 14.0. Four RCTs involving 293 participants were included in our study. The present meta-analysis indicated that there were significant differences between infrapatellar and suprapatellar intramedullary nail regarding the total blood loss, VAS scores, Lysholm knee scores, and fluoroscopy times. Suprapatellar intramedullary nailing could significantly reduce total blood loss, postoperative knee pain, and fluoroscopy times compared to infrapatellar approach. Additionally, it was associated with an improved Lysholm knee scores. High-quality RCTs were still required for further investigation.

  18. Risks of concomitant trauma to the knee in lower limb long bone shaft fractures: A retrospective analysis from a prospective study population.

    PubMed

    Kumar, Brajesh; Borgohain, Bhaskar; Balasubramanian, S; Sathyanarayana, V; Muthusamy, M

    2014-01-01

    Numerous associated injuries (bony and/or soft tissue lesions) occur commonly in conjunction with fractures of the femoral shaft in young patients after high-energy injuries. Knee ligamentous injuries, historically called as the internal derangements of the knee or IDK, are mostly not visible in plain radiographs taken in the emergency and these injuries are likely to be overlooked by clinicians because first attention always goes to open wounds and radiologically visible injuries of the limb whenever a patient is received in a trauma unit. A total of 93 cases of lower limb long bone fractures were retrospectively analyzed from materials of a prospective study conducted on consecutive patients having high-velocity injuries to lower limb long bones with a view to confirm or rule out concomitant ipsilateral IDK in cases of femoral and tibial shaft fractures, that already employed a policy of focused clinical examination followed by arthroscopy of the ipsilateral knee, immediately after operative fracture fixation under the same anesthesia. The goal was to determine the incidence of concomitant internal derangement of the ipsilateral knee and to understand any value of adding arthroscopy to detect concomitant IDK in lower limb long bone fractures besides careful intraoperative examination to propose a recommendation thereof. Concomitant knee injury was found in 14 femoral fractures and 1 tibial fracture. Fifteen out of 93 (16%) such cases had concomitant knee ligamentous or meniscal injures. A total of 13 anterior cruciate and 4 posterior cruciate tears, 11 collateral ligament tears, and 10 meniscal injuries were confirmed in these 15 knees. Femoral shaft fractures were associated with a high incidence of serious ligamentous, meniscal, and chondral injury. Twelve out of 41 femoral fractures had chondral injuries (contusion), especially of the patello-femoral articulation, identifiable during arthroscopy. One should have high index of suspicion about internal knee

  19. Femur loading in feet-first fall experiments using an anthropomorphic test device.

    PubMed

    Thompson, Angela; Bertocci, Gina; Smalley, Craig

    2018-03-31

    Femur fractures are a common orthopedic injury in young children. Falls account for a large portion of accidental femur fractures in young children, but there is also a high prevalence of femur fractures in child abuse, with falls often provided as false histories. Objective information regarding fracture potential in short distance fall scenarios may aid in assessing whether a child's injuries are the result of abuse or an accidental fall. Knowledge of femur loading is the first step towards understanding likelihood of fracture in a fall. Characterize femur loading during feet-first free falls using a surrogate representing a 12-month-old child. The femur and hip joint of a surrogate representing a 12-month-old were modified to improve biofidelity and measure femur loading; 6-axis load cells were integrated into the proximal and distal femur. Femur modification was based upon CT imaging of cadaveric femurs in children 10-14 months of age. Using the modified 12-month-old surrogate, feet-first free falls from 69 cm and 119 cm heights onto padded carpet and linoleum were conducted to assess fall dynamics and determine femur loading. Femur compression, bending moment, shear and torsional moment were measured for each fall. Fall dynamics differed across fall heights, but did not substantially differ by impact surface type. Significant differences were found in all loading conditions across fall heights, while only compression and bending loads differed between carpet and linoleum surfaces. Maximum compression, bending, torsion and shear occurred in 119 cm falls and were 572 N, 23 N-m, 11 N-m and 281 N, respectively. Fall dynamics play an important role in the biomechanical assessment of falls. Fall height was found to influence both fall dynamics and femur loading, while impact surface affected only compression and bending in feet-first falls; fall dynamics did not differ across carpet and linoleum. Improved pediatric thresholds are necessary to predict

  20. Prediction of fracture load and stiffness of the proximal femur by CT-based specimen specific finite element analysis: cadaveric validation study.

    PubMed

    Miura, Michiaki; Nakamura, Junichi; Matsuura, Yusuke; Wako, Yasushi; Suzuki, Takane; Hagiwara, Shigeo; Orita, Sumihisa; Inage, Kazuhide; Kawarai, Yuya; Sugano, Masahiko; Nawata, Kento; Ohtori, Seiji

    2017-12-16

    Finite element analysis (FEA) of the proximal femur has been previously validated with large mesh size, but these were insufficient to simulate the model with small implants in recent studies. This study aimed to validate the proximal femoral computed tomography (CT)-based specimen-specific FEA model with smaller mesh size using fresh frozen cadavers. Twenty proximal femora from 10 cadavers (mean age, 87.1 years) were examined. CT was performed on all specimens with a calibration phantom. Nonlinear FEA prediction with stance configuration was performed using Mechanical Finder (mesh,1.5 mm tetrahedral elements; shell thickness, 0.2 mm; Poisson's coefficient, 0.3), in comparison with mechanical testing. Force was applied at a fixed vertical displacement rate, and the magnitude of the applied load and displacement were continuously recorded. The fracture load and stiffness were calculated from force-displacement curve, and the correlation between mechanical testing and FEA prediction was examined. A pilot study with one femur revealed that the equations proposed by Keller for vertebra were the most reproducible for calculating Young's modulus and the yield stress of elements of the proximal femur. There was a good linear correlation between fracture loads of mechanical testing and FEA prediction (R 2 = 0.6187) and between the stiffness of mechanical testing and FEA prediction (R 2 = 0.5499). There was a good linear correlation between fracture load and stiffness (R 2 = 0.6345) in mechanical testing and an excellent correlation between these (R 2 = 0.9240) in FEA prediction. CT-based specimen-specific FEA model of the proximal femur with small element size was validated using fresh frozen cadavers. The equations proposed by Keller for vertebra were found to be the most reproducible for the proximal femur in elderly people.

  1. HUMeral shaft fractures: measuring recovery after operative versus non-operative treatment (HUMMER): a multicenter comparative observational study.

    PubMed

    Mahabier, Kiran C; Van Lieshout, Esther M M; Bolhuis, Hugo W; Bos, P Koen; Bronkhorst, Maarten Wga; Bruijninckx, Milko M M; De Haan, Jeroen; Deenik, Axel R; Dwars, Boudewijn J; Eversdijk, Martin G; Goslings, J Carel; Haverlag, Robert; Heetveld, Martin J; Kerver, Albert J H; Kolkman, Karel A; Leenhouts, Peter A; Meylaerts, Sven A G; Onstenk, Ron; Poeze, Martijn; Poolman, Rudolf W; Punt, Bas J; Roerdink, W Herbert; Roukema, Gert R; Sintenie, Jan Bernard; Soesman, Nicolaj M R; Tanka, Andras K F; Ten Holder, Edgar J T; Van der Elst, Maarten; Van der Heijden, Frank H W M; Van der Linden, Frits M; Van der Zwaal, Peer; Van Dijk, Jan P; Van Jonbergen, Hans-Peter W; Verleisdonk, Egbert J M M; Vroemen, Jos P A M; Waleboer, Marco; Wittich, Philippe; Zuidema, Wietse P; Polinder, Suzanne; Verhofstad, Michael H J; Den Hartog, Dennis

    2014-02-11

    Fractures of the humeral shaft are associated with a profound temporary (and in the elderly sometimes even permanent) impairment of independence and quality of life. These fractures can be treated operatively or non-operatively, but the optimal tailored treatment is an unresolved problem. As no high-quality comparative randomized or observational studies are available, a recent Cochrane review concluded there is no evidence of sufficient scientific quality available to inform the decision to operate or not. Since randomized controlled trials for this injury have shown feasibility issues, this study is designed to provide the best achievable evidence to answer this unresolved problem. The primary aim of this study is to evaluate functional recovery after operative versus non-operative treatment in adult patients who sustained a humeral shaft fracture. Secondary aims include the effect of treatment on pain, complications, generic health-related quality of life, time to resumption of activities of daily living and work, and cost-effectiveness. The main hypothesis is that operative treatment will result in faster recovery. The design of the study will be a multicenter prospective observational study of 400 patients who have sustained a humeral shaft fracture, AO type 12A or 12B. Treatment decision (i.e., operative or non-operative) will be left to the discretion of the treating surgeon. Critical elements of treatment will be registered and outcome will be monitored at regular intervals over the subsequent 12 months. The primary outcome measure is the Disabilities of the Arm, Shoulder, and Hand score. Secondary outcome measures are the Constant score, pain level at both sides, range of motion of the elbow and shoulder joint at both sides, radiographic healing, rate of complications and (secondary) interventions, health-related quality of life (Short-Form 36 and EuroQol-5D), time to resumption of ADL/work, and cost-effectiveness. Data will be analyzed using univariate

  2. Closed retrograde multiple intramedullary Kirschner wires fixation for humeral shaft fractures with the limb flexed over an articulated support

    PubMed Central

    Sié, Essoh J.B.; Kacou, Aka D.; Traoré, A.; Mobiot, C.; Bamba, I.; Lambin, Y.

    2014-01-01

    Objective To evaluate the results of multiple closed intramedullary Kirschner wiring via a supracondylar entry point for humeral shaft fractures. Patients and methods The charts of 37 patients with humeral shaft fractures treated with the Hackethal's technique between January 2007 and December 2011 were reviewed retrospectively. The operation was performed with the patient lying in supine (n = 22) or lateral (n = 15) position. The elbow was flexed over an articulated support with the arm kept in a vertical position. Thirty-three patients were available for final evaluation with a mean follow-up delay of 14 (range, 6–24) months. We were concerned about fracture union, range of motion of the shoulder and the elbow, and complications. Final evaluation used the criteria by Qidwai. Results Bone union rate was 94%. Restriction of ranges of motion of the shoulder more than 20° was noticed in two patients due to protruding wires. Three patients developed limitation of elbow extension owing to backing out of the wires. The overall results were excellent (n = 26; 79%), good (n = 4; 12%), and poor (n = 3; 9%). Conclusion Closed Hackethal's technique using K-wires gives satisfactory results in terms of bone union and elbow and shoulder function in selected humeral shaft fractures. The articulated support precludes the transolecranon traction. PMID:25983469

  3. Effectiveness of sonography assisted minimal invasive plate osteosynthesis (MIPO) compare with fluoroscope assisted in femoral shaft fracture: A cadaveric study.

    PubMed

    Saengsin, Jirawat; Vaseenon, Tanawat; Pattamapaspong, Nuttaya; Kritsaneephaiboon, Apipop

    2017-08-01

    A minimal invasive plate osteosynthesis (MIPO) has an advantage of biological soft tissue preservation that consists of preserving bony blood supply, fracture hematoma and less soft tissue damage which leads to decreasing of infection rate and rapid bone healing. However, the radiation exposure is still a disadvantage of this technique. A sonography that provides dynamic real time imaging may be used as an alternative technique for assisting MIPO. The aim of this study was to compare the effectiveness of MIPO in femoral shaft fracture between the sonography assisted and the fluoroscopy assisted. Twenty-eight cadaveric limbs were subjected to create femoral shaft fracture. Then, sonography assisted reduction with temporary external fixation and MIPO were performed. Images of the sonography and the fluoroscopy were recorded including before reduction, after reduction and after MIPO in order to identify fracture displacements in anteroposterior and mediolateral directions. Moreover, the anterior and posterior distances from edge of the bone to the plate were measured to confirm plate position. The effectiveness of this technique was defined as the proper plate position and acceptable alignment after fixation. All distances from the sonography and the fluoroscopy were also analyzed and compared using Pearson correlation and Bland-Altman method to assess the agreements between two tests. All of the subjects were met the criteria for acceptable alignment. We found only three femoral shaft fracture (11%) operated with MIPO by sonography assisted that showed slipped plate off femoral bones. According to Pearson correlation, there were good to excellent agreements in term of measuring fracture displacement before (Pearson Correlation >0.7) and after reduction (Pearson Correlation >0.7) between these two tests. There was moderate agreement regarding to evaluation of plate position (Pearson Correlation 03.-0.7). When we compared two methods of measurement using Bland

  4. Tibia shaft fractures: costly burden of nonunions.

    PubMed

    Antonova, Evgeniya; Le, T Kim; Burge, Russel; Mershon, John

    2013-01-26

    Tibia shaft fractures (TSF) are common for men and women and cause substantial morbidity, healthcare use, and costs. The impact of nonunions on healthcare use and costs is poorly described. Our goal was to investigate patient characteristics and healthcare use and costs associated with TSF in patients with and without nonunion. We retrospectively analyzed medical claims in large U.S. managed care claims databases (Thomson Reuters MarketScan®, 16 million lives). We studied patients ≥ 18 years old with a TSF diagnosis (ICD-9 codes: 823.20, 823.22, 823.30, 823.32) in 2006 with continuous pharmaceutical and medical benefit enrollment 1 year prior and 2 years post-fracture. Nonunion was defined by ICD-9 code 733.82 (after the TSF date). Among the 853 patients with TSF, 99 (12%) had nonunion. Patients with nonunion had more comorbidities (30 vs. 21, pre-fracture) and were more likely to have their TSF open (87% vs. 70%) than those without nonunion. Patients with nonunion were more likely to have additional fractures during the 2-year follow-up (of lower limb [88.9% vs. 69.5%, P < 0.001], spine or trunk [16.2% vs. 7.2%, P = 0.002], and skull [5.1% vs. 1.3%, P = 0.008]) than those without nonunion. Nonunion patients were more likely to use various types of surgical care, inpatient care (tibia and non-tibia related: 65% vs. 40%, P < 0.001) and outpatient physical therapy (tibia-related: 60% vs. 42%, P < 0.001) than those without nonunion. All categories of care (except emergency room costs) were more expensive in nonunion patients than in those without nonunion: median total care cost $25,556 vs. $11,686, P < 0.001. Nonunion patients were much more likely to be prescribed pain medications (99% vs. 92%, P = 0.009), especially strong opioids (90% vs. 76.4%, P = 0.002) and had longer length of opioid therapy (5.4 months vs. 2.8 months, P < 0.001) than patients without nonunion. Tibia fracture patterns in men differed from those in women. Nonunions in TSF's are associated

  5. [Treatment of multi-segment fracture of complex femoral shaft with instrument-assisted reduction combined with intramedullary interlocking nail fixation].

    PubMed

    Fan, Ke-Jie; Chen, Ke; Ma, Wen-Long; Tian, Ke-Wei; Ye, Ye; Chen, Hong-Gan; Tang, Yan-Feng; Cai, Hong-Min

    2018-05-25

    To investigate the effect of minimally invasive mini-incision and instrumented reduction combined with interlocking intramedullary nailing in the treatment of patients with multi-segment fracture of complex femoral shaft. From January 2013 to January 2016, 32 patients with multiple fractures segments of femoral shaft were treated with instrumentation-assisted reduction combined with interlocking intramedullary nailing, including 22 males and 10 females with an average age of 45 years old ranging 17 to 68 years old. The time from injured to operation was 5 to 10 days with an average of 7 days. After admission, routine tibial tubercle or supracondylar bone traction was performed. The patient's general condition was evaluated, the operation time and intraoperative blood loss were recorded. According to Thorsen femoral fracture morphology evaluation criteria and Hohl knee function evaluation of postoperative efficacy, postoperative fracture healing, complications and postoperative recovery of limb function were observed. All patients were followed up for 6 to 24 months with an average of 12 months. The operative time ranged from 48 to 76 minutes with an average of 67 min. The intraoperative blood loss was 150 to 400 ml with an average of 220 ml. The surgical incisions all achieved grade A healing. The fractures reached the clinical standard of healing. The fracture healing time ranged from 4.2 to 10.8 months with an average of 5.7 months. There were no nonunion, incision infection and internal fixation fracture, failure and other complications. According to Thorsen femoral fracture morphology evaluation criteria, the result was excellent in 28 cases, good in 3 cases, fair in 1 case. According to Hohl knee function evaluation criteria, the result was excellent in 30 cases, good in 2 cases. Instrument-assisted reduction combined with interlocking intramedullary nail fixation is a safe and effective method for the treatment of complex femoral shaft fractures. It has

  6. Studying the effect of photodynamic therapy (PDT) to enhance healing of femur fractures using polarimetric second-harmonic generation microscopy

    NASA Astrophysics Data System (ADS)

    Golaraei, Ahmad; Raja, Vaishnavi; Akens, Margarete K.; Wilson, Brian C.; Barzda, Virginijus

    2017-07-01

    Linear polarization-in, polarization-out second-harmonic generation microscopy was used to study the effect of Photodynamic therapy treatment on enhancing the healing of femur fracture by investigating the ultrastructure of collagen as a major component of bone matrix.

  7. Failure analysis of stainless steel femur fixation plate.

    PubMed

    Hussain, P B; Mohammad, M

    2004-05-01

    Failure analysis was performed to investigate the failure of the femur fixation plate which was previously fixed on the femur of a girl. Radiography, metallography, fractography and mechanical testing were conducted in this study. The results show that the failure was due to the formation of notches on the femur plate. These notches act as stress raisers from where the cracks start to propagate. Finally fracture occurred on the femur plate and subsequently, the plate failed.

  8. Simultaneous Bilateral Femur Neck Fracture in A Young Adult with Chronic Renal Failure- A Case Report and Review of Literature.

    PubMed

    V, Sathyanarayana; Patel, Maulik Tulsibhai; S, Raghavan; D, Naresh

    2015-01-01

    Pathological bilateral femoral neck fracture due to renal osteodystrophy is rare. This is a report of a chronic renal failure patient who had sustained bilateral intra-capsular displaced fracture neck of femur following an episode of convulsion and the difficulties encountered in early diagnosis and treatment. The pathophysiology of renal osteodystrophy and the treatment of hip fractures in patients with renal failure are also discussed. A 23 years old male patient admitted with h/o dysuria, pyuria and loss of appetite since 3 months. He was a known case of chronic renal failure and reflux nephropathy. On investigating, patient's renal parameters were high and he was started with haemodialysis. The next day patient had c/o bilateral hip pain and inability to move bilateral lower limbs following an episode of seizure. Radiograph of pelvis showed vertical sub capital fractures of bilateral neck of femur. In this patient, considering his age, general condition & prognosis, an elective surgery in the form of bilateral uncemented modular bipolar hemiarthroplasty was done. Overall risk of hip fracture among patients with chronic renal failure is considerably higher than in the general population, independent of age and gender. Simultaneous spontaneous bilateral fractures of the femoral neck are rare and a delayed diagnosis is usual. The study of etiological factors of these fractures is essential to guide us in choosing the treatment of choice. Obviously patient's age, life expectancy as well as renal co morbidity has an influence over deciding treatment and outcome.

  9. Reoperation following open reduction and plate fixation of displaced mid-shaft clavicle fractures.

    PubMed

    Ashman, Bradley D; Slobogean, Gerard P; Stone, Trevor B; Viskontas, Darius G; Moola, Farhad O; Perey, Bertrand H; Boyer, Dory S; McCormack, Robert G

    2014-10-01

    Operative fixation of displaced, mid-shaft clavicle fractures has become an increasingly common practice. With this emerging trend, data describing patient outcomes with longer follow-up are necessary. We retrospectively reviewed the medical records of subjects treated with plate fixation for displaced mid-shaft clavicle fractures from 2003 to 2009 at a Level I trauma hospital. All subjects were greater than 12 months post-index surgery. Treatment involved ORIF with either a low-contact dynamic compression plate (LCDC) or a contoured plate (pre-contoured or pelvic reconstruction plate). Our primary outcome was reoperation for any indication. 143 subjects were included. The mean age was 36 ± 14 years and the mean time to reoperation or chart review was 33 months. Contoured plates were used in 64% of cases and LCDC plates were used in the remaining subjects. Twenty-nine subjects (20%) underwent reoperation: 23.5% of subjects treated with LCDC plates and 18.5% of subjects treated with contoured plates (p=0.52). Indications for reoperation included implant irritation (n=25), implant failure (n=2), and non-union (n=2). There was near statistically significant association with reoperation and female gender (p=0.05) but no association between reoperation and age (p=0.14), fracture class (p=0.53), plate type (p=0.49), or plate location (p=0.93). The mean QuickDASH score for the population surveyed was 8.8 (5.5-12.1; 95% CI) with near statistically significant and clinically relevant difference between those considering reoperation and those not 22.3 (8.6-36.0; 95% CI) versus 6.7 (3.6-9.8; 95% CI). This study represents a large series of displaced clavicle fractures treated with open reduction and plate fixation. Reoperation following plate fixation is relatively common, but primarily due to implant irritation. No difference in reoperation rates between plate types or location could be detected in our current sample size. Also, excellent functional outcomes continue to be

  10. [Comparison of mid-term surgical results between plate and intramedullary nail for humeral shaft fracture].

    PubMed

    Zhao, G; Liu, H N; Li, N; He, L; Wu, X B

    2016-10-11

    Objective: To evaluate the mid-term clinical efficacy of plate and intramedullary nail for humeral shaft fracture. Methods: In this retrospective study a total of 122 patients with humeral shaft fracture were divided into 2 groups according to surgery type from May 2010 to July 2012. There were 63 patients in plate group and 59 patients in intramedullary nail group. The factors related to the operation for each group were compared respectively. The clinical outcome was evaluated by the Neer scores, Myao scores and EuroQol 5 dimensions scores (EQ-5D). All the patients were followed up periodically in the next 3 years. Results: There were no significant differences between the two groups on hospital stay and time of returning to work ( P >0.05). While the operation time, amount of intraoperative blood loss and complication rate were less in intramedullary nail group. The mean follow-up duration was (41.2±4.2) months in plate group and (42.1±4.7) months in intramedullary nail group respectively. At the last follow-up the postoperative Neer scores, Myao scores and EQ-5D scores showed no significant differences between the 2 groups[Neer: (93.8±6.1) vs(92.1±4.2); Myao: (94.9±2.9) vs(96.2±1.5), P >0.05]. There were no cases complicated with nonunion, delayed union, infection and deformity during the follow-up period. Conclusions: The mid-term outcome of open reduction and internal fixation with plate and close reduction with intramedullary nail for humeral shaft fracture is satisfactory. Although both surgeries are safe and effective, they also have some defaults. The doctors should choose the right surgery carefully according to the actual situation of the patients.

  11. Biomechanical evaluation of fracture fixation constructs using a variable-angle locked periprosthetic femur plate system.

    PubMed

    Hoffmann, Martin F; Burgers, Travis A; Mason, James J; Williams, Bart O; Sietsema, Debra L; Jones, Clifford B

    2014-07-01

    In the United States there are more than 230,000 total hip replacements annually, and periprosthetic femoral fractures occur in 0.1-4.5% of those patients. The majority of these fractures occur at the tip of the stem (Vancouver type B1). The purpose of this study was to compare the biomechanically stability and strength of three fixation constructs and identify the most desirable construct. Fifteen medium adult synthetic femurs were implanted with a hip prosthesis and were osteotomized in an oblique plane at the level of the implant tip to simulate a Vancouver type B1 periprosthetic fracture. Fractures were fixed with a non-contact bridging periprosthetic proximal femur plate (Zimmer Inc., Warsaw, IN). Three proximal fixation methods were used: Group 1, bicortical screws; Group 2, unicortical screws and one cerclage cable; and Group 3, three cerclage cables. Distally, all groups had bicortical screws. Biomechanical testing was performed using an axial-torsional testing machine in three different loading modalities (axial compression, lateral bending, and torsional/sagittal bending), next in axial cyclic loading to 10,000 cycles, again in the three loading modalities, and finally to failure in torsional/sagittal bending. Group 1 had significantly greater load to failure and was significantly stiffer in torsional/sagittal bending than Groups 2 and 3. After cyclic loading, Group 2 had significantly greater axial stiffness than Groups 1 and 3. There was no difference between the three groups in lateral bending stiffness. The average energy absorbed during cyclic loading was significantly lower in Group 2 than in Groups 1 and 3. Bicortical screw placement achieved the highest load to failure and the highest torsional/sagittal bending stiffness. Additional unicortical screws improved axial stiffness when using cable fixation. Lateral bending was not influenced by differences in proximal fixation. To treat periprosthetic fractures, bicortical screw placement should be

  12. Tibia shaft fractures: costly burden of nonunions

    PubMed Central

    2013-01-01

    Background Tibia shaft fractures (TSF) are common for men and women and cause substantial morbidity, healthcare use, and costs. The impact of nonunions on healthcare use and costs is poorly described. Our goal was to investigate patient characteristics and healthcare use and costs associated with TSF in patients with and without nonunion. Methods We retrospectively analyzed medical claims in large U.S. managed care claims databases (Thomson Reuters MarketScan®, 16 million lives). We studied patients ≥ 18 years old with a TSF diagnosis (ICD-9 codes: 823.20, 823.22, 823.30, 823.32) in 2006 with continuous pharmaceutical and medical benefit enrollment 1 year prior and 2 years post-fracture. Nonunion was defined by ICD-9 code 733.82 (after the TSF date). Results Among the 853 patients with TSF, 99 (12%) had nonunion. Patients with nonunion had more comorbidities (30 vs. 21, pre-fracture) and were more likely to have their TSF open (87% vs. 70%) than those without nonunion. Patients with nonunion were more likely to have additional fractures during the 2-year follow-up (of lower limb [88.9% vs. 69.5%, P < 0.001], spine or trunk [16.2% vs. 7.2%, P = 0.002], and skull [5.1% vs. 1.3%, P = 0.008]) than those without nonunion. Nonunion patients were more likely to use various types of surgical care, inpatient care (tibia and non-tibia related: 65% vs. 40%, P < 0.001) and outpatient physical therapy (tibia-related: 60% vs. 42%, P < 0.001) than those without nonunion. All categories of care (except emergency room costs) were more expensive in nonunion patients than in those without nonunion: median total care cost $25,556 vs. $11,686, P < 0.001. Nonunion patients were much more likely to be prescribed pain medications (99% vs. 92%, P = 0.009), especially strong opioids (90% vs. 76.4%, P = 0.002) and had longer length of opioid therapy (5.4 months vs. 2.8 months, P < 0.001) than patients without nonunion. Tibia fracture patterns in men

  13. Multifocal humeral fractures.

    PubMed

    Maresca, A; Pascarella, R; Bettuzzi, C; Amendola, L; Politano, R; Fantasia, R; Del Torto, M

    2014-02-01

    Multifocal humeral fractures are extremely rare. These may affect the neck and the shaft, the shaft alone, or the diaphysis and the distal humerus. There is no classification of these fractures in the literature. From 2004 to 2010, 717 patients with humeral fracture were treated surgically at our department. Thirty-five patients presented with an associated fracture of the proximal and diaphyseal humerus: synthesis was performed with plate and screws in 34 patients, and the remaining patient had an open fracture that was treated with an external fixator. Mean follow-up was 3 years and 3 months. A classification is proposed in which type A fractures are those affecting the proximal and the humeral shaft, type B the diaphysis alone, and type C the diaphysis in association with the distal humerus. Type A fractures are then divided into three subgroups: A-I, undisplaced fracture of the proximal humerus and displaced shaft fracture; A-II: displaced fracture of the proximal and humeral shaft; and A-III: multifragmentary fracture affecting the proximal humerus and extending to the diaphysis. Multifocal humeral fractures are very rare and little described in the literature, both for classification and treatment. The AO classification describes bifocal fracture of the humeral diaphysis, type B and C. The classification suggested in this article mainly concerns fractures involving the proximal and humeral shaft. A simple classification of multifocal fractures is suggested to help the surgeon choose the most suitable type of synthesis for surgical treatment. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. [Manipulative reduction and small splint fixation combined with micromovement exercise for treatment of humeral shaft fractures].

    PubMed

    Tang, Hao-chen; Xiang, Ming; Chen, Hang; Hu, Xiao-chuan; Yang, Guo-yong

    2016-01-01

    To investigate the therapeutic efficacy of bone-setting manipulative reduction and small splint fixation combined with micro-movement theory exercise for treatment of humeral shaft fractures. From March 2011 to February 2014, 64 cases of humeral shaft fractures were treated by bone-setting manipulative reduction and small splint fixation including 28 males and 36 females with an average age of 38.1 years old ranging from 22 to 67 years old. According to the classification of AO/OTA, there were 10 cases of type A1, 12 cases of type A2,11 cases of type A3,10 cases of type B1,12 cases of type B2, 7 cases of type B3, 2 cases of type C1, 1 case of type C2, 1 case of type C3. After close reduction early functional exercise performed according to micro-movement theory. All patients had no other parts of the fractures, neurovascular injury, and serious medical problems. Patients were followed up for fracture healing, shoulder and elbow joint function recovery, and curative effect. All patients were followed up from 10 to 12 months with an average of 10.3 months. Of them, 2 cases had a small amount of callus growth at 3 months after close reduction, so instead of operation; 2 cases appeared radial nerve symptoms after close reduction ,so instead of operation. Other patients were osseous healing, the time was 8 to 12 weeks with an average of 10.2 weeks. After osseous healing, according to Constant-Murley score system ,the average score was (93.5 ± 3.2) points, the result was excellent in 29 cases, good in 29 cases, fair in 6 cases, excellent and good rate was 90.3%; according to the Mayo score system, the average score was (93.7 ± 4.2) points, the result was excellent in 35 cases, good in 23 cases, fair in 6 cases, excellent and good rate was 91.9%. Bone-setting manipulative reduction and small splint fixation combined with micromovement theory exercise for treatment of humeral shaft fractures has advantage of positive effect, easy and inexpensive method, the treatment has

  15. Completed Ulnar Shaft Stress Fracture in a Fast-Pitch Softball Pitcher.

    PubMed

    Wiltfong, Roger E; Carruthers, Katherine H; Popp, James E

    2017-03-01

    Stress fractures of the upper extremity have been previously described in the literature, yet reports of isolated injury to the ulna diaphysis or olecranon are rare. The authors describe a case involving an 18-year-old fast-pitch softball pitcher. She presented with a long history of elbow and forearm pain, which was exacerbated during a long weekend of pitching. Her initial physician diagnosed her as having forearm tendinitis. She was treated with nonsurgical means including rest, anti-inflammatory medications, therapy, and kinesiology taping. She resumed pitching when allowed and subsequently had an acute event immediately ceasing pitching. She presented to an urgent care clinic that evening and was diagnosed as having a complete ulnar shaft fracture subsequently needing surgical management. This case illustrates the need for a high degree of suspicion for ulnar stress fractures in fast-pitch soft-ball pitchers with an insidious onset of unilateral forearm pain. Through early identification and intervention, physicians may be able to reduce the risk of injury progression and possibly eliminate the need for surgical management. [Orthopedics. 2017; 40(2):e360-e362.]. Copyright 2016, SLACK Incorporated.

  16. Peri-anterior cruciate ligament reconstruction femur fracture: a biomechanical analysis of the femoral tunnel as a stress riser.

    PubMed

    Han, Yung; Sardar, Zeeshan; McGrail, Scott; Steffen, Thomas; Martineau, Paul A

    2011-12-01

    Sixteen case reports of distal femur fractures as post-operative complications after anterior cruciate ligament (ACL) reconstruction have been described in the literature. The femoral tunnel has been suggested as a potential stress riser for fracture formation. Additionally, double bundle ACL reconstructions may compound this risk. This is the first biomechanical study to examine the significance of a stress riser effect of the femoral tunnel(s) after ACL reconstruction. The hypotheses tested in this study are that the femoral tunnel acts as a stress riser for fracture and that this effect increases with the size of the tunnel (8 mm vs. 10 mm) and with the number of tunnels (1 vs. 2). Femoral tunnels simulating single bundle (SB) hamstring graft (8 mm), bone-patellar tendon-bone graft (10 mm), and double bundle (DB) ACL reconstruction (7, 6 mm) were drilled in fourth-generation saw bones. These three experimental groups and a control group consisting of native saw bones without tunnels were loaded to failure. All fractures occurred through the tunnels in the DB group, whereas fractures did not consistently occur through the tunnels in the SB groups. The mean fracture load was 6,145N ± 471N in the native group, 5,691N ± 198N in the 8 mm SB group, 5,702N ± 282N in the 10 mm SB group, and 4,744N ± 418N in the DB group. The mean fracture load for the DB group was significantly lower when compared to the native, 8 mm SB, and 10 mm SB groups independently (P value = 0.0016, 0.0060, and 0.0038, respectively). The mean fracture loads for neither SB groups were not significantly different from the native group. An anatomically placed femoral tunnel in single bundle ACL reconstruction in our experimental model was not a significant stress riser to fracture, whereas the two femoral tunnels in double bundle ACL reconstruction significantly decreased load to failure. The results support the sparsity of reported peri-ACL reconstruction femur fractures in single femoral

  17. Fascia iliaca compartment nerve block versus systemic pain control for acute femur fractures in the pediatric emergency department.

    PubMed

    Neubrand, Tara L; Roswell, Kelley; Deakyne, Sara; Kocher, Kendra; Wathen, Joseph

    2014-07-01

    To compare management of acute femur fractures in children who received a fascia iliaca compartment nerve block (FICNB) to those who received systemic intravenously administered analgesics in the pediatric emergency department. The comparison evaluated frequency of use, effectiveness, and associated adverse event profiles. Study population was derived from a retrospective chart review of pediatric patients sustaining acute femur fractures between 2005 and 2009. Cases (received FICNB) were compared with controls (only systemic analgesia) in terms of effectiveness and adverse event. Outcomes included total doses of systemic medications received and comparison of preintervention and postintervention pain scores. Two hundred fifty-nine charts were reviewed: 158 who received FICNB versus 101 who did not. The median dose of systemic medications was 1 dose lower in the FICNB group compared with the systemic medications group. This remained significant after controlling for age and preintervention pain scores (P = 0.02). Median postintervention pain scores in the FICNB group were 1.5 points lower than those in the systemic medications group. This remained significant while controlling for preintervention pain scores and age (P < 0.01). There was no difference in the total adverse events between the FICNB and the control group in either the unadjusted or adjusted analyses (P = 0.08). The FICNB group had 2 seizure episodes, one of which had associated subarachnoid hemorrhage. No patient in either group experienced bradycardia, arrhythmia, visual disturbance, abnormal hearing, mouth numbness, motor tremors, pain or bleeding at injection site, or prolonged nerve block. We report on the largest number of FICNBs administered in a pediatric emergency department for acute femur fractures. Effectiveness, as measured by pain scores and total doses of systemic analgesia, was improved in the FICNB group versus the control. There was no difference in adverse events between the groups.

  18. A method for assessment of the shape of the proximal femur and its relationship to osteoporotic hip fracture.

    PubMed

    Gregory, J S; Testi, D; Stewart, A; Undrill, P E; Reid, D M; Aspden, R M

    2004-01-01

    The shape of the proximal femur has been demonstrated to be important in the occurrence of fractures of the femoral neck. Unfortunately, multiple geometric measurements frequently used to describe this shape are highly correlated. A new method, active shape modeling (ASM) has been developed to quantify the morphology of the femur. This describes the shape in terms of orthogonal modes of variation that, consequently, are all independent. To test this method, digitized standard pelvic radiographs were obtained from 26 women who had suffered a hip fracture and compared with images from 24 age-matched controls with no fracture. All subjects also had their bone mineral density (BMD) measured at five sites using dual-energy X-ray absorptiometry. An ASM was developed and principal components analysis used to identify the modes which best described the shape. Discriminant analysis was used to determine which variable, or combination of variables, was best able to discriminate between the groups. ASM alone correctly identified 74% of the individuals and placed them in the appropriate group. Only one of the BMD values (Ward's triangle) achieved a higher value (82%). A combination of Ward's triangle BMD and ASM improved the accuracy to 90%. Geometric variables used in this study were weaker, correctly classifying less than 60% of the study group. Logistic regression showed that after adjustment for age, body mass index, and BMD, the ASM data was still independently associated with hip fracture (odds ratio (OR)=1.83, 95% confidence interval 1.08 to 3.11). The odds ratio was calculated relative to a 10% increase in the probability of belonging to the fracture group. Though these initial results were obtained from a limited data set, this study shows that ASM may be a powerful method to help identify individuals at risk of a hip fracture in the future.

  19. Cortical thickness estimation of the proximal femur from multi-view dual-energy X-ray absorptiometry (DXA)

    NASA Astrophysics Data System (ADS)

    Tsaousis, N.; Gee, A. H.; Treece, G. M.; Poole, K. E. S.

    2013-02-01

    Hip fracture is the leading cause of acute orthopaedic hospital admission amongst the elderly, with around a third of patients not surviving one year post-fracture. Although various preventative therapies are available, patient selection is difficult. The current state-of-the-art risk assessment tool (FRAX) ignores focal structural defects, such as cortical bone thinning, a critical component in characterizing hip fragility. Cortical thickness can be measured using CT, but this is expensive and involves a significant radiation dose. Instead, Dual-Energy X-ray Absorptiometry (DXA) is currently the preferred imaging modality for assessing hip fracture risk and is used routinely in clinical practice. Our ambition is to develop a tool to measure cortical thickness using multi-view DXA instead of CT. In this initial study, we work with digitally reconstructed radiographs (DRRs) derived from CT data as a surrogate for DXA scans: this enables us to compare directly the thickness estimates with the gold standard CT results. Our approach involves a model-based femoral shape reconstruction followed by a data-driven algorithm to extract numerous cortical thickness point estimates. In a series of experiments on the shaft and trochanteric regions of 48 proximal femurs, we validated our algorithm and established its performance limits using 20 views in the range 0°-171°: estimation errors were 0:19 +/- 0:53mm (mean +/- one standard deviation). In a more clinically viable protocol using four views in the range 0°-51°, where no other bony structures obstruct the projection of the femur, measurement errors were -0:07 +/- 0:79 mm.

  20. Reverse Less Invasive Stabilization System (LISS) Plating for Proximal Femur Fractures in Poliomyelitis Survivors: A Report of Two Cases.

    PubMed

    Yao, Chen; Jin, Dongxu; Zhang, Changqing

    2017-11-15

    BACKGROUND Poliomyelitis is a neuromuscular disease which causes muscle atrophy, skeletal deformities, and disabilities. Treatment of hip fractures on polio-affect limbs is unique and difficult, since routine fixation methods like nailing may not be suitable due to abnormal skeletal structures. CASE REPORT We report one femoral neck fracture and one subtrochanteric fracture in polio survivors successfully treated with reverse less invasive stabilization system (LISS) plating technique. Both fractures were on polio-affected limbs with significant skeletal deformities and low bone density. A contralateral femoral LISS plate was applied upside down to the proximal femur as an internal fixator after indirect or direct reduction. Both patients had uneventful bone union and good functional recovery. CONCLUSIONS Reverse LISS plating is a safe and effective technique to treat hip fractures with skeletal deformities caused by poliomyelitis.

  1. Epidemiology of fractures of the proximal third of the femur in elderly patients☆

    PubMed Central

    Daniachi, Daniel; Netto, Alfredo dos Santos; Ono, Nelson Keiske; Guimarães, Rodrigo Pereira; Polesello, Giancarlo Cavalli; Honda, Emerson Kiyoshi

    2015-01-01

    Objective This was an epidemiological study on fractures of the proximal third of the femur in elderly patients who were treated at a teaching hospital in the central region of São Paulo. Methods The subjects were patients over the age of 60 years who were attended over a 1-year period. A questionnaire seeking basic sociodemographic data and information on comorbidities presented and medications used was drawn up. The circumstances of the fractures and their characteristics, the treatment instituted and the intra-hospital mortality rate were evaluated. Results The 113 patients included in the study presented a mean age of 79 years. The ratio between the sexes was three women to each man. Only 30.4% of the patients reported having osteoporosis and only 0.9% had had treatment for the disease. Low-energy trauma was the cause of 92.9% of the fractures. Femoral neck fractures accounted for 42.5% of the fractures and trochanteric fractures, 57.5%. Five patients did not undergo operations; 39 underwent joint replacement; and 69 underwent osteosynthesis. The mean length of hospital stay was 13.5 days and the mean length of waiting time until surgery was 7 days. The intra-hospital mortality rate was 7.1%. Conclusion The patients attended at this institution presented an epidemiological profile similar to what is found in the Brazilian literature. Chronic kidney failure is a significant factor with regard to intra-hospital mortality. Preventive measures such as early diagnosis and treatment of osteoporosis and regular physical activity practices were not implemented. PMID:26401497

  2. Fat embolism syndrome in an adolescent before surgical treatment of an isolated closed tibial shaft fracture.

    PubMed

    Nawaf, Cayce B; Kelly, Derek M; Warner, William C; Beaty, James H; Rhodes, Leslie; Sawyer, Jeffrey R

    2012-12-01

    Fat embolism syndrome (FES) occurs most commonly in adults with high-energy trauma, especially fractures of the long-bones and pelvis. Because of unique age-related physiologic differences in the immature skeleton, as well as differences in fracture management in pediatric patients, FES is rare in children. To our knowledge, this is the first case report of FES occurring before surgical fixation of a closed tibial shaft fracture in an adolescent. A 16-year-old, 109 kg, Caucasian adolescent boy developed FES after closed diaphyseal fractures of the distal tibia and fibula, showing signs of respiratory distress and mental status changes. The FES resolved with supportive respiratory care and intramedullary nailing of the fracture was done without further respiratory compromise. FES is uncommon in children and adolescents. A high index of suspicion is required to make the diagnosis promptly and institute appropriate treatment. Intramedullary nailing of a long-bone fracture can be done safely and successfully after resolution of the FES.

  3. Which Surgical Treatment for Open Tibial Shaft Fractures Results in the Fewest Reoperations? A Network Meta-analysis.

    PubMed

    Foote, Clary J; Guyatt, Gordon H; Vignesh, K Nithin; Mundi, Raman; Chaudhry, Harman; Heels-Ansdell, Diane; Thabane, Lehana; Tornetta, Paul; Bhandari, Mohit

    2015-07-01

    Open tibial shaft fractures are one of the most devastating orthopaedic injuries. Surgical treatment options include reamed or unreamed nailing, plating, Ender nails, Ilizarov fixation, and external fixation. Using a network meta-analysis allows comparison and facilitates pooling of a diverse population of randomized trials across these approaches in ways that a traditional meta-analysis does not. Our aim was to perform a network meta-analysis using evidence from randomized trials on the relative effect of alternative approaches on the risk of unplanned reoperation after open fractures of the tibial diaphysis. Our secondary study endpoints included malunion, deep infection, and superficial infection. A network meta-analysis allows for simultaneous consideration of the relative effectiveness of multiple treatment alternatives. To do this on the subject of surgical treatments for open tibial fractures, we began with systematic searches of databases (including EMBASE and MEDLINE) and performed hand searches of orthopaedic journals, bibliographies, abstracts from orthopaedic conferences, and orthopaedic textbooks, for all relevant material published between 1980 and 2013. Two authors independently screened abstracts and manuscripts and extracted the data, three evaluated the risk of bias in individual studies, and two applied Grading of Recommendation Assessment, Development and Evaluation (GRADE) criteria to bodies of evidence. We included all randomized and quasirandomized trials comparing two (or more) surgical treatment options for open tibial shaft fractures in predominantly (ie, > 80%) adult patients. We calculated pooled estimates for all direct comparisons and conducted a network meta-analysis combining direct and indirect evidence for all 15 comparisons between six stabilization strategies. Fourteen trials published between 1989 and November 2011 met our inclusion criteria; the trials comprised a total of 1279 patients surgically treated for open tibial

  4. An evaluation of flexible intramedullary nail fixation in femoral shaft fractures in paediatric age group.

    PubMed

    Kumar, Sanjay; Roy, Sandip Kumar; Jha, Amrish Kumar; Chatterjee, Debdutta; Banerjee, Debabrata; Garg, Anant Kumar

    2011-06-01

    Sixty-two femoral shaft fractures in 60 patients treated by elastic intramedullary nailing with mean age of the patients being 9.2 years (range 5 years to 12 years) and average follow-up of 15 months (range 7 months to 60 months) are evaluated. Twenty-eight fractures were fixed with titanium elastic nail while 34 fractures were fixed with Enders nail. There were 40 midshaft fractures, 18 proximal femoral and 4 were fractures of distal third. Fracture patterns were transverse in 35, short oblique in 14 cases and 13 were spiral fractures. Mean age of union in this series was 17 weeks (range 12 weeks to 28 weeks). Ten cases had complications, 5 had nail tip irritation, 3 varus or valgus malalignment and 2 had delayed union. In this series, we did not have any non-union, refracture, limb length discrepancy or any major infection. The result demonstrates 100% union rate irrespective of the age, weight and height of the patient. Regardless of the site of fracture and their pattern, it united every time with elastic nail fixation. We did not find and mismatch in the results of fractures stabilised with titanium elastic nail with that of elastic stainless steel nail.

  5. Computed tomography for occult fractures of the proximal femur, pelvis, and sacrum in clinical practice: single institution, dual-site experience.

    PubMed

    Mandell, Jacob C; Weaver, Michael J; Khurana, Bharti

    2018-06-01

    The purpose of this study was to evaluate the diagnostic performance of CT for assessment of occult fractures of the proximal femur, pelvis, and sacrum. A retrospective review was performed on patients who received a CT of the hip or pelvis for suspected occult fracture after negative or equivocal radiographs performed within 24 h. The official radiology report was utilized for the determination of CT findings and calculation of sensitivity and specificity. Surgical reports, MRI reports, and clinical follow-up were used as the standard of reference. Sensitivity and specificity were calculated with 95% confidence intervals. Seventy-four patients received CT of the hip or pelvis for clinical concern for occult fracture after negative or equivocal radiographs. By the reference standard, a total of 40 fractures were present in 25/74 (33.8%) patients, including 35 conservatively treated fractures of the greater trochanter, pelvis, and sacrum, and 5 operatively treated proximal femoral fractures. A total of 14/74 (18.9%) of patients had an MRI within 1 day of CT. MRI identified an operatively treated femoral neck fracture not seen on CT and an operatively treated intertrochanteric fracture, which CT described as a greater trochanteric fracture. There were two false negative conservatively treated pelvic fractures not seen on CT but diagnosed on MRI. On a per-patient basis, CT had an overall sensitivity of 88% (22/25; 95% confidence intervals 69-97%), specificity of 98% (48/49; 95% confidence intervals 89-100%), and negative predictive value of 94%. For the five operative proximal femoral fractures, the sensitivity of CT was 60% (3/5; 95% confidence intervals 15-95%), specificity was 99% (68/69; 95% confidence intervals 92-100%), and negative predictive value was 97%. In the clinical setting of suspected occult fracture, the sensitivity of clinical CT reports for detection of any type of fracture of the proximal femur, pelvis, or sacrum was 88%. For the small number of

  6. Evaluation of malrotation following intramedullary nailing in a femoral shaft fracture model: Can a 3D c-arm improve accuracy?

    PubMed

    Ramme, Austin J; Egol, Jonathan; Chang, Gregory; Davidovitch, Roy I; Konda, Sanjit

    2017-07-01

    Difficulty determining anatomic rotation following intramedullary (IM) nailing of the femur continues to be problematic for surgeons. Clinical exam and fluoroscopic imaging of the hip and knee have been used to estimate femoral version, but are inaccurate. We hypothesize that 3D c-arm imaging can be used to accurately measure femoral version following IM nailing of femur fractures to prevent rotational malreduction. A midshaft osteotomy was created in a femur Sawbone to simulate a transverse diaphyseal fracture. An intramedullary (IM) nail was inserted into the Sawbone femur without locking screws or cephalomedullary fixation. A goniometer was used to simulate four femoral version situations after IM nailing: 20° retroversion, 0° version, 15° anteversion, and 30° anteversion. In each simulated position, 3D c-arm imaging and, for comparison purposes, perfect lateral radiographs of the knee and hip were performed. The femoral version of each simulated 3D and fluoroscopic case was measured and the results were tabulated. The measured version from the 3D c-arm images was 22.25° retroversion, 0.66° anteversion, 19.53° anteversion, and 25.15° anteversion for the simulated cases of 20° retroversion, 0° version, 15° anteversion, and 30° anteversion, respectively. The lateral fluoroscopic views were measured to be 9.66° retroversion, 12.12° anteversion, 20.91° anteversion, and 18.77° anteversion for the simulated cases, respectively. This study demonstrates the utility of a novel intraoperative method to evaluate femur rotational malreduction following IM nailing. The use of 3D c-arm imaging to measure femoral version offers accuracy and reproducibility. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Augmentation plating in hypertrophic non-union after nail fixation of femoral shaft fracture compared with exchange plating.

    PubMed

    Jiang, Liangjun; Pan, Zhijun; Zheng, Qiang

    2014-01-01

    Augmentation plating has been used successfully to treat hypertrophic non-union after nail fixation. This study compared the efficacy of augmentation plating and exchange plating for treating hypertrophic non-union of femoral shaft fracture after intramedullary nail fixation. A total of 12 patients received augmentation plating and 15 patients received exchange plating as treatment for femoral shaft hypertrophic non-union. The procedures were conducted at our medical centre between January 2005 and January 2012. Clinical follow-up was conducted at 2 weeks, 1 month and then monthly until union was achieved to compare union time, operation time, bleeding and complications between the two groups. All patients underwent follow-up examinations until fracture union was achieved. The average length of follow-up time after the second treatment was (18.37 ± 3.28) months. The time needed for union was (4.17 ± 0.94) months in the augmentation plating group and (5.33 ± 1.72) months in the exchange plating group. The operation time was (90.00 ± 17.58) minutes in the augmentation plating group and (160.00 ± 25.35) minutes in the exchange plating group. The amount of blood loss during the operation was (270.00 ± 43.32) ml in the augmentation plating group and (530.00 ± 103.65) ml in the exchange plating group. Both groups showed significant difference (P < 0.05) in their results. No complications were reported after the second operation. Augmentation plating after nail fixation could remove local rotation instability, facilitate simple operation, create minimal damage and enable exercise for early functional recovery. Therefore, augmentation plating is excellent for treating hypertrophic non-union after nail fixation in femoral shaft fracture.

  8. Shock wave treatment shows dose-dependent enhancement of bone mass and bone strength after fracture of the femur.

    PubMed

    Wang, Ching-Jen; Yang, Kuender D; Wang, Feng-Sheng; Hsu, Chia-Chen; Chen, Hsiang-Ho

    2004-01-01

    Shock wave treatment is believed to improve bone healing after fracture. The purpose of this study was to evaluate the effect of shock wave treatment on bone mass and bone strength after fracture of the femur in a rabbit model. A standardized closed fracture of the right femur was created with a three-point bending method in 24 New Zealand white rabbits. Animals were randomly divided into three groups: (1) control (no shock wave treatment), (2) low-energy (shock wave treatment at 0.18 mJ/mm2 energy flux density with 2000 impulses), and (3) high-energy (shock wave treatment at 0.47 mJ/mm2 energy flux density with 4000 impulses). Bone mass (bone mineral density (BMD), callus formation, ash and calcium contents) and bone strength (peak load, peak stress and modulus of elasticity) were assessed at 12 and 24 weeks after shock wave treatment. While the BMD values of the high-energy group were significantly higher than the control group (P = 0.021), the BMD values between the low-energy and control groups were not statistically significant (P = 0.358). The high-energy group showed significantly more callus formation (P < 0.001), higher ash content (P < 0.001) and calcium content (P = 0.003) than the control and low-energy groups. With regard to bone strength, the high-energy group showed significantly higher peak load (P = 0.012), peak stress (P = 0.015) and modulus of elasticity (P = 0.011) than the low-energy and control groups. Overall, the effect of shock wave treatment on bone mass and bone strength appears to be dose dependent in acute fracture healing in rabbits.

  9. Asymmetry in gait pattern following tibial shaft fractures - a prospective one-year follow-up study of 49 patients.

    PubMed

    Larsen, Peter; Laessoe, Uffe; Rasmussen, Sten; Graven-Nielsen, Thomas; Berre Eriksen, Christian; Elsoe, Rasmus

    2017-01-01

    Despite the high number of studies evaluating the outcomes following tibial shaft fractures, the literature lacks studies including objective assessment of patients' recovery regarding gait pattern. The purpose of the present study was to evaluate whether gait patterns at 6 and 12 months post-operatively following intramedullary nailing of a tibial shaft fracture are different compared with a healthy reference population. The study design was a prospective cohort study. The primary outcome measurement was the gait patterns at 6 and 12 months post-operatively measured with a 6-metre-long pressure-sensitive mat. The mat registers footprints and present gait speed, cadence as well as temporal and spatial parameters of the gait cycle. Gait patterns were compared to a healthy reference population. 49 patients were included with a mean age of 43.1 years (18-79 years). Forty-three patients completed the 12-month follow-up (88%). Gait speed and cadence were significantly increased between the 6- and 12-month follow-up (P<0.001). At 6-month follow-up, patients showed considerable asymmetry in the injured leg compared with the non-injured leg: single-support time 12.8% shorter, swing-time 12.8% longer, step-length 11.9% shorter, and rotation of the foot increased by 32.3%. At the 12-month follow-up, gait asymmetry become almost normalized compared to a healthy reference group. In patients treated by intramedullary nailing following a tibial shaft fracture, gait asymmetry accompanied with slower speed and cadence are common during the first 6 months and become normalized compared with a healthy reference population between 6 and 12 months post-operatively. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Comparison of fibrinogen- and collagen-based treatments for penetrating wounds with comminuted femur fractures in a Swine model.

    PubMed

    Rothwell, Stephen W; Sawyer, Evelyn; Lombardini, Eric; Royal, Joseph; Tang, Haiyin; Selwyn, Reed; Bodo, Michael; Settle, Timothy L

    2013-01-01

    Military servicemembers in combat operations often sustain injuries to the extremities from highspeed projectiles, resulting in bleeding and comminuted open fractures. Severe injury with bone fragmentation can result in limb amputation. Surgical treatment options include materials that promote osteogenesis and bone proliferation, such as growth hormones, stem cells, or mineralized matrix adjuncts. However, none of these are amenable to use by the first responder, nor do they address the question of hemorrhage control, which is a common problem in traumatic injuries. Our hypothesis was that treatment with a fibrinogen-based protein mixture at the time of the bone injury will provide both hemostasis and a supportive environment for preservation of injured bone. A comminuted femur fracture was produced in 28 female Yorkshire swine, and one of four treatments was instilled into the wound immediately after injury. Each animal was evaluated for the following parameters: inflammation, new bone growth, osteoclast proliferation, callus formation, and femur wound cavity fill, using post-mortem computed tomography and analysis of histological sections. Overall, salmon fibrinogen?thrombin and porcine fibrinogen?thrombin showed a trend for improved healing based on bone filling and calcification. However, statistically significant differences could not be established between treatment groups. These findings indicate that a fibrinogen?thrombin matrix may be a useful as an immediate response product to enhance fracture healing. Salmon fibrinogen?thrombin has the advantages of cost and a pathogen profile compared to mammalian fibrinogens. 2013.

  11. Comparison of knee function in patients with a healed fracture of the femoral shaft fixed with retrograde and antegrade intramedullary nailing.

    PubMed

    Andrzejewski, Krzysztof; Panasiuk, Michał; Grzegorzewski, Andrzej; Synder, Marek

    2013-10-31

    BACKGROUND. Despite extensive current knowledge about fractures of the femoral shaft, the choice between antegrade and retrograde intramedullary (IM) nailing with respect to the future function of the joint serving to introduce the nail continues to raise controversy. To compare knee function in patients with a healed fracture of the femoral shaft fixed by antegrade vs. retrograde IM nailing. MATERIAL AND METHODS. The study involved a group of 65 individuals with traumatic fractures of the femoral shaft who underwent stabilisation with IM nails in the years 2001-2010. Thirty-two cases were retrograde nails (Group R) and 33 antegrade nails (Group A). Patient age at trauma ranged from 19 to 91 years (mean: 47). Knee function was assessed in both groups with the KOOS, KSS1 and KSS2 scoring systems. RESULTS. Knee function as assessed with KOOS differed significantly between retrograde and antegrade nailing, with a greater incidence of poor and fair results in the former and more excellent outcomes in the latter group (p=0.0133). As regards KSS1 and KSS2, there were no significant differences between the groups (p=0.1947, p=0.4038). The range of motion was 86-125 degrees in Group R and 121-125 degrees in Group A. Knee pain was reported by 37.5% of the patients treated with retrograde nailing and 39.4% of those who had the IM nail inserted via the antegrade approach (p=0.22). The mean time to bone union was 180 days in Group R and 219 days in Group A (p=0.25). Age and presence of osteoarthritis at trauma significantly lowered the KOOS (p=0.0027, p= 0.005) and KSS (p=0.0002, p=0.002) scores, as well as the knee range of motion (p=0.0014, p=0.004) CONCLUSIONS. 1. Knee function following retrograde and antegrade IM nailing to stabilise femoral shaft fractures was comparable. 2. The choice of IM nailing method should not be based solely on orthopaedic indications, but also on the severity of osteoarthritis present at trauma.

  12. Numerical simulation of stress amplification induced by crack interaction in human femur bone

    NASA Astrophysics Data System (ADS)

    Alia, Noor; Daud, Ruslizam; Ramli, Mohammad Fadzli; Azman, Wan Zuki; Faizal, Ahmad; Aisyah, Siti

    2015-05-01

    This research is about numerical simulation using a computational method which study on stress amplification induced by crack interaction in human femur bone. Cracks in human femur bone usually occur because of large load or stress applied on it. Usually, the fracture takes longer time to heal itself. At present, the crack interaction is still not well understood due to bone complexity. Thus, brittle fracture behavior of bone may be underestimated and inaccurate. This study aims to investigate the geometrical effect of double co-planar edge cracks on stress intensity factor (K) in femur bone. This research focuses to analyze the amplification effect on the fracture behavior of double co-planar edge cracks, where numerical model is developed using computational method. The concept of fracture mechanics and finite element method (FEM) are used to solve the interacting cracks problems using linear elastic fracture mechanics (LEFM) theory. As a result, this study has shown the identification of the crack interaction limit (CIL) and crack unification limit (CUL) exist in the human femur bone model developed. In future research, several improvements will be made such as varying the load, applying thickness on the model and also use different theory or method in calculating the stress intensity factor (K).

  13. [Early total care pattern for intertrochanteric fracture of femur in the elderly].

    PubMed

    Gu, Jie; Kang, Xin-yong; Xu, Hong-wei; Li, Yong-fu; Zahng, Bin; Guo, Jian; He, Zhen-nian

    2016-06-01

    To evaluate clinical results of early total care (ETC) treatment for elderly patients with intertrochanteric femur fractures. Clinical data of 106 elderly patients with intertrochanteric fracture treated from January 2012 and February 2015 were retrospectively studied. According to whether receiving the early total care mode, the patients were divided into 2 groups, 34 cases were diagnosed and treated with early total care pattern (ETC group), including 14 males and 20 females with an average age of (74.88 ± 4.38) years old ranging from 70 to 86. According to Evans types, 4 cases were type I, 5 cases were type II, 13 cases were type III, 11 cases were type IV, 1 case was type V. Seventy-two patients were treated with conventional trauma method (conventional group), including 35 males and 37 females with an average age of (74.46 ± 3.63) years old ranging from 70 to 85. According to Evans type, 8 cases were type I ,13 cases were type II, 25 cases were type III, 25 cases were type IV, and 1 case was type V. All fractures were treated with proximal femoral nails anti-rotation (PFNA). Operative time, hospital stays, leaving bed time, complications, cases of death at 1 year after operation, postoperative Harris score at 12 months were observed and compared. All patients were followed up, the time of ETC group ranged from 9 to 18 months with an average of 13.29 ± 1.51, and the time in conventional group ranged from 12 to 16 months with an average 12.93 ± 1.15, while there was no significant difference between two groups in time of following-up (t = 1.368, P = 0.174). There was no significant meaning in cases of death between ETC group (2 cases) and conventional group (8 cases). Three cases occurred complications in ETC group, and 20 cases in conventional group,there was obvious meaning between two groups (χ² = 0.739, P = 0.318). Operative time,hospital stays,leaving bed time in ETC group respectively was (2.03 ± 0.67) d, (15.41 ± 2.87) d and (3.62 ± 0.74) d

  14. Open Tibia Shaft Fractures and Soft-Tissue Coverage: The Effects of Management by an Orthopaedic Microsurgical Team.

    PubMed

    VandenBerg, James; Osei, Daniel; Boyer, Martin I; Gardner, Michael J; Ricci, William M; Spraggs-Hughes, Amanda; McAndrew, Christopher M

    2017-06-01

    To compare the timing of soft-tissue (flap) coverage and occurrence of complications before and after the establishment of an integrated orthopaedic trauma/microsurgical team. Retrospective cohort study. A single level 1 trauma center. Twenty-eight subjects (13 pre- and 15 post-integration) with open tibia shaft fractures (OTA/AO 42A, 42B, and 42C) treated with flap coverage between January 2009 and March 2015. Flap coverage for open tibia shaft fractures treated before ("preintegration") and after ("postintegration") implementation of an integrated orthopaedic trauma/microsurgical team. Time from index injury to flap coverage. The unadjusted median time to coverage was 7 days (95% confidence interval, 5.9-8.1) preintegration, and 6 days (95% confidence interval, 4.6-7.4) postintegration (P = 0.48). For preintegration, 9 (69%) of the patients experienced complications, compared with 7 (47%) postintegration (P = 0.23). After formation of an integrated orthopaedic trauma/microsurgery team, we observed a 1-day decrease in median days to coverage from index injury. Complications overall were lowered in the postintegration group, although statistically insignificant. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  15. Lower limb fracture presentations at a regional hospital.

    PubMed

    Holloway, K L; Yousif, D; Bucki-Smith, G; Hosking, S; Betson, A G; Williams, L J; Brennan-Olsen, S L; Kotowicz, M A; Sepetavc, A; Pasco, J A

    2017-08-28

    We found that lower limb fractures, which were largely the result of minimal trauma, had high levels of hospitalisation, length of stay and surgery. It is therefore important to prevent fractures at all sites to avoid the associated morbidity and mortality. Hip fractures are a major cause of morbidity and mortality, particularly in older women. In comparison, less is known about the epidemiology and burden of other lower limb fractures. The study aimed to investigate the epidemiology and burden of these fractures. Incident fractures of the hip, femur, tibia/fibula, ankle and foot in women (≥ 20 years) managed through the University Hospital Geelong, Australia, were ascertained from 1 Jan. 2014 to 31 Dec. 2014 from radiology reports. Age, cause of fracture, post-fracture hospitalisation, surgery, length of stay and discharge location were ascertained from medical records. We identified 585 fractures of the lower limb (209 hip, 42 femur, 41 tibia/fibula, 162 ankle, 131 foot). Most fractures were sustained by women aged ≥ 50 years. Fractures were largely a result of minimal trauma. Most women with hip or femur fractures were hospitalised; fewer were hospitalised for fractures at other sites. Surgery for fracture followed the same pattern as hospitalisations. Length of stay was the highest for hip and femur fractures and the lowest for foot fractures. Women with hip or femur fractures were discharged to rehabilitation more often than home. Fractures at other sites were most commonly discharged home. Fractures of the lower limb occurred frequently in older women. Hospitalisation and subsequent surgery were common in cases of hip and femur fractures. It is important for prevention strategies to target fractures at a range of skeletal sites to reduce costs, hospitalisations, loss of independence and reduced quality of life.

  16. Femoral neck shaft angles: A radiological anthropometry study.

    PubMed

    Adekoya-Cole, Thomas Oduntan; Akinmokun, Olasode Israel; Soyebi, Kofoworola O; Oguche, Omachoko Emmanuel

    2016-01-01

    Most of the available orthopaedic implants were designed and manufactured based on data from Western population whose skeletal dimensions are different from those of Africans. This study was conducted to determine the value of the neck-shaft angle (NSA) of Nigerians living in Lagos for the purpose of adequate planning, preparation, and pre-operative selection of orthopaedic implants for surgeries involving the femoral neck and stocking of orthopaedic implants in hospitals located in resource poor countries like Nigeria. This was a retrospective study which involved measuring the NSAs of anterior-posterior views of pelvic radiographs of adult patients reported "normal study" by the radiologist. A total of 264 femoral necks were analysed from 132 patients' radiographs comprising of 68 males and 64 females. The average NSA for an adult Nigerian living in Lagos is 130.77° ± 6.03° with mean NSA value of 131.28° ± 6.56° for the right and 130.22° ± 5.18° for the left. The mean value of NSA for an adult male is 131.57° ± 5.66° whereas the mean value for an adult female is 129.97° ± 6.33°. The value of NSA obtained from this study should be considered during the surgical fixation of the neck of femur fractures or osteotomies around the neck of the femur of adult Nigerians. It should also be noted during designing and bioengineering construction of orthopaedic implants and hip prosthesis for Nigerians.

  17. Effects of third fragment size and displacement on non-union of femoral shaft fractures after locking for intramedullary nailing.

    PubMed

    Lee, J R; Kim, H-J; Lee, K-B

    2016-04-01

    The femoral shaft fractures with large fragments makes anatomical reduction challenging and often results in non-union. In some studies, the degree of fragment displacement was reported to have affected non-union, but the association between the one fragment size and degree of displacement has not been fully clarified. Therefore we performed a retrospective study to assess: (1) the more influential factor of non-union: the degree of fragment displacement, or the fragment size? (2) the non-union rates according to different sizes and degrees of displacement. The degree of displacement is the more potent factor of non-union than the third fragment size in femoral shaft fractures. We assessed retrospectively 64 cases, which could be followed up for longer than one year. Fragments were divided according to the length of their long axis into three groups: group A (0-3.9cm), (n=21); group B (4-7.9cm), (n=22); group C (8cm or more), (n=21). Fragment displacement was also assessed in the proximal (P) or distal (D) end to the nearest cortex of the femoral shaft, and divided into the following groups: group P1 (n=44) or D1 (n=47), (0-9mm); group P2 (n=10) or D2 (n=11), (10-19mm); group P3 (n=7) or D3 (n=3), (20-29mm); and group P4 (n=3) or D4 (n=3), (30mm or more). The bone union rate was 86% in the small (less than 8cm) fragment groups and 71% in the large (8cm or more) fragment group (P=0.046). With respect to the degree of displacement, the union rate was lower (P=0.001) and the average union time was longer (P=0.012) in the 20mm or more group for both the proximal fragment part and the distal fragment part (P=0.002, P=0.014). A logistic regression analysis underlined the displacement in the proximal site (OR: 0.298, 95% CI: 0.118-0.750) as in the distal site (OR: 0.359, 95% CI: 0.162-0.793) as a larger effect on union rate than the fragment size that as no effect in logistic regression (OR 3.8, 95% CI: 0.669-21.6). Non-union develops significantly more frequently in

  18. Damage characterization on human femur bone by means of ultrasonics and acoustic emission

    NASA Astrophysics Data System (ADS)

    Strantza, M.; Polyzos, D.; Louis, O.; Boulpaep, F.; Van Hemelrijck, D.; Aggelis, D. G.

    2015-07-01

    Human bone tissue is characterized as a material with high brittleness. Due to this nature, visible signs of cracking are not easy to be detected before final failure. The main objective of this work is to investigate if the acoustic emission (AE) technique can offer valuable insight to the fracture process of human femur specimens as in other engineering materials characterization. This study describes the AE activity during fracture of whole femur bones under flexural load. Before fracture, broadband AE sensors were used in order to measure parameters like wave velocity dispersion and attenuation. Waveform parameters like the duration, rise time and average frequency, were also examined relatively to the propagation distance as a preparation for the AE monitoring during fracture. After the ultrasonic study, the samples were partly cast in concrete and fixed as cantilevers. A point load was applied on the femur head, which due to the test geometry resulted in a combination of two different patterns of fracture, bending and torsion. Two AE broadband sensors were placed in different points of the sample, one near the fixing end and the other near the femur head. Preliminary analysis shows that parameters like the number of acquired AE signals and their amplitude are well correlated with the load history. Furthermore, the parameters of rise time and frequency can differentiate the two fracture patterns. Additionally, AE allows the detection of the load at the onset of fracture from the micro-cracking events that occur at the early loading stages, allowing monitoring of the whole fracture process. Parameters that have been used extensively for monitoring and characterization of fracture modes of engineering materials seem to poses characterization power in the case of bone tissue monitoring as well.

  19. Surgical strategies in polytraumatized patients with femoral shaft fractures - comparing a German and an Australian level I trauma centre.

    PubMed

    Andruszkow, Hagen; Dowrick, Adam S; Frink, Michael; Zeckey, Christian; Krettek, Christian; Hildebrand, Frank; Edwards, Elton R; Mommsen, Philipp

    2013-08-01

    Femoral shaft fractures are one of the most common injuries in multiple trauma patients. Due to their prognostic relevance, there is an ongoing controversial discussion as to the optimal treatment strategy in terms of Damage Control Orthopaedics (DCO) and Early Total Care (ETC). We aimed to describe the differences in fracture management and clinical outcome of multiple trauma patients with concomitant femoral shaft fractures treated at a German and an Australian level I trauma centre using the same inclusion criteria. Polytraumatized patients (ISS ≥ 16) with a femoral shaft fracture aged ≥ 16 years treated at a German and an Australian trauma centre between 2003 and 2007 were included. According to ETC and DCO management principles, we evaluated demographic parameters as well as posttraumatic complications and clinical outcome. Seventy-three patients were treated at the German and 134 patients at the Australian trauma centre. DCO was performed in case of increased injury severity in both hospitals. Prolonged mechanical ventilation time, and length of ICU and hospital stay were demonstrated in DCO treatment regardless of the trauma centre. No differences concerning posttraumatic complications and survival were found between both centres. Survival of patients after DCO was similar to those managed using ETC despite a greater severity of injury and lower probability of survival. There was no difference in the incidence of ARDS. DCO was, however, associated with a greatly increased length of time on mechanical ventilation and length of stay in the ICU. We found no differences concerning patient demographics or clinical outcomes in terms of incidence of ARDS, MODS, or mortality. As such, we propose that comparability between German and Australian trauma populations is justified. Despite a higher ISS in the DCO group, there were no differences in posttraumatic complications and survival depending on ETC or DCO treatment. Further research is required to confirm

  20. A prospective multi-center study of intramedullary nailing vs casting of stable tibial shaft fractures.

    PubMed

    Obremskey, William T; Cutrera, Norele; Kidd, Christopher M

    2017-03-01

    The purpose of this study was to determine optimal treatment of stable tibial shaft fractures using intramedullary nailing (IMN) or casting. We performed a multi-center prospective study cohort. Patients with stable tibia shaft fractures meeting Sarmiento's criteria (isolated closed fractures with less than 12 mm of shortening and 10° of angulation) were enrolled prospectively and treated with either a reamed IMN with static interlocking screws or closed reduction followed by long-leg casting. Both groups were weight bearing following surgery. Radiographs were taken until union, and range of motion of knee and ankle joints was assessed. Malalignment (>5°) and malunion (>10°) were determined. Functional outcome measures using short musculoskeletal assessment scores (SMFA) and a knee pain score were scheduled at 6 weeks, 3 months and 6 months. At 3 months, differences between the casting and IMN groups were noted in return to work (6/15 vs 3/17, P < 0.05); ankle dorsiflexion (7° vs 12°, P < 0.05); plantar flexion (28° vs 39°, P < 0.05); and SMFA domains of Dysfunction Index, Bother Index, daily activities, emotional status, and arm/hand function (P < 0.05). The SMFA mobility function demonstrated a significant trend (P = 0.065). At 6 months, malalignment was present in 3/15 in the casting group and in 1/17 in the IMN group (P = 0.02). Malunion was present in 1/15 in the cast group. One fracture in the casting group went on to nonunion and required late IMN placement at 7 months and eventually healed. There were no differences in ankle motion, SMFA scores, or return to work. There was no difference in knee pain between the groups as measured by VAS and Court-Brown pain scale at 6 months. Patients with stable tibia fractures treated with intramedullary nailing have improved clinical and functional outcomes at 3 months compared with those treated with casting, but there are no differences in any other outcome measure. Patients treated in a

  1. Correlation of Hip Fracture with Other Fracture Types: Toward a Rational Composite Hip Fracture Endpoint

    PubMed Central

    Colón-Emeric, Cathleen; Pieper, Carl F.; Grubber, Janet; Van Scoyoc, Lynn; Schnell, Merritt L; Van Houtven, Courtney Harold; Pearson, Megan; Lafleur, Joanne; Lyles, Kenneth W.; Adler, Robert A.

    2016-01-01

    Purpose With ethical requirements to the enrollment of lower risk subjects, osteoporosis trials are underpowered to detect reduction in hip fractures. Different skeletal sites have different levels of fracture risk and response to treatment. We sought to identify fracture sites which cluster with hip fracture at higher than expected frequency; if these sites respond to treatment similarly, then a composite fracture endpoint could provide a better estimate of hip fracture reduction. Methods Cohort study using Veterans Affairs and Medicare administrative data. Male Veterans (n=5,036,536) aged 50-99 years receiving VA primary care between1999-2009 were included. Fractures were ascertained using ICD9 and CPT codes and classified by skeletal site. Pearson correlation coefficients, logistic regression and kappa statistics, were used to describe the correlation between each fracture type and hip fracture within individuals, without regards to the timing of the events. Results 595,579 (11.8%) men suffered 1 or more fractures and 179,597 (3.6%) suffered 2 or more fractures during the time under study. Of those with one or more fractures, rib was the most common site (29%), followed by spine (22%), hip (21%) and femur (20%). The fracture types most highly correlated with hip fracture were pelvic/acetabular (Pearson correlation coefficient 0.25, p<0.0001), femur (0.15, p<0.0001), and shoulder (0.11, p<0.0001). Conclusions Pelvic, acetabular, femur, and shoulder fractures cluster with hip fractures within individuals at greater than expected frequency. If we observe similar treatment risk reductions within that cluster, subsequent trials could consider use of a composite endpoint to better estimate hip fracture risk. PMID:26151123

  2. Redefining Optimal Nail to Medullary Canal Diameter Ratio in Stainless Steel Flexible Intramedullary Nailing of Pediatric Femur Fractures.

    PubMed

    Shaha, James S; Cage, Jason M; Black, Sheena R; Wimberly, Robert L; Shaha, Steven H; Riccio, Anthony I

    The ideal canal fill for flexible intramedullary fixation of pediatric femoral shaft fractures is considered to be 80% based upon relatively few clinical studies. The purpose of this study is to assess the relationship between the summed nail to intramedullary canal diameter (ND/MCD) ratio and alignment at radiographic union following flexible intramedullary nailing (FIMN) of pediatric femoral shaft fractures. An Internal Review Board approved, retrospective review of a consecutive series of patients who sustained a femoral shaft fracture treated by retrograde, stainless steel FIMN was performed at a single level 1 pediatric trauma center from 2005 to 2012. Preoperative radiographs were analyzed to determine fracture pattern, location, and isthmic canal diameter. ND/MCD ratio was calculated using the sum of the known nail diameters and the measured isthmic diameter. Radiographs at bony union were reviewed to measure shortening, coronal angulation, and sagittal angulation. ND/MCD ratio was analyzed to determine correlative factors with final radiographic outcomes. In total, 261 children underwent retrograde FIMN at an average age of 8.2 years (range, 2.2 to 17.0 y). ND/MCD ratio of ≥80% was seen in 108 (41.4%) patients. When compared with those with <80% ND/MCD ratio, there were no significant differences in age (8.8 vs. 8.0 y), sex (76.9% vs. 71.0% males), or body mass index (18.5 vs. 17.2 kg/m). There were significantly more length unstable fractures in the <80% ND/MCD ratio group (49.4% vs. 29.7%; P<0.01). Radiographic outcome was no different with respect to coronal angulation (2.7 vs. 3.0 degrees), sagittal angulation (3.0 vs. 3.2 degrees), or shortening (2.5 vs. 4.1 mm). ND/MCD ratio of ≥70% was seen in 176 (67.4%) patients and, when compared with the <70% ND/MCD ratio group, there were no differences in shortening (3.3 vs. 3.9 mm), coronal angulation (2.8 vs. 3.0 degrees), or sagittal angulation (3.0 vs. 3.4 degrees). Finally, 6.9% of the population (18

  3. Clavicle Shaft Fractures in Adolescents.

    PubMed

    Yang, Scott; Andras, Lindsay

    2017-01-01

    Midshaft clavicle fractures in adolescents are common. Recent literature in adults fractures favors open reduction and plate fixation for significantly displaced and/or shortened midshaft clavicle fractures, although whether this applies to adolescents remains debatable. This article reviews the current literature and controversy in the management of displaced adolescent clavicle fractures. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Associations of Age, BMI, and Years of Menstruation with Proximal Femur Strength in Chinese Postmenopausal Women: A Cross-Sectional Study.

    PubMed

    Kang, Huili; Chen, Yu-Ming; Han, Guiyuan; Huang, Hua; Chen, Wei-Qing; Wang, Xidan; Zhu, Ying-Ying; Xiao, Su-Mei

    2016-01-23

    This study aimed to elucidate the associations of age, BMI, and years of menstruation with proximal femur strength in Chinese postmenopausal women, which may improve the prediction of hip fracture risk. A cross-sectional study was conducted in 1322 Chinese postmenopausal women recruited from communities. DXA images were used to generate bone mineral density (BMD) and geometric parameters, including cross-sectional area (CSA), outer diameter (OD), cortical thickness (CT), section modulus (SM), buckling ratio (BR) at the narrow neck (NN), intertrochanter (IT), and femoral shaft (FS). Relationships of age, BMI, and years of menstruation with bone phenotypes were analyzed with the adjustment of height, age at menarche, total daily physical activity, education, smoking status, calcium tablet intake, etc. Age was associated with lower BMD, CSA, CT, SM, and higher BR (p < 0.05), which indicated a weaker bone strength at the proximal femur. BMI and years of menstruation had the positive relationships with proximal femur strength (p < 0.05). Further analyses showed that the ranges of absolute value of change slope per year, per BMI or per year of menstruation were 0.14%-1.34%, 0.20%-2.70%, and 0.16%-0.98%, respectively. These results supported that bone strength deteriorated with aging and enhanced with higher BMI and longer time of years of menstruation in Chinese postmenopausal women.

  5. Associations of Age, BMI, and Years of Menstruation with Proximal Femur Strength in Chinese Postmenopausal Women: A Cross-Sectional Study

    PubMed Central

    Kang, Huili; Chen, Yu-Ming; Han, Guiyuan; Huang, Hua; Chen, Wei-Qing; Wang, Xidan; Zhu, Ying-Ying; Xiao, Su-Mei

    2016-01-01

    This study aimed to elucidate the associations of age, BMI, and years of menstruation with proximal femur strength in Chinese postmenopausal women, which may improve the prediction of hip fracture risk. A cross-sectional study was conducted in 1322 Chinese postmenopausal women recruited from communities. DXA images were used to generate bone mineral density (BMD) and geometric parameters, including cross-sectional area (CSA), outer diameter (OD), cortical thickness (CT), section modulus (SM), buckling ratio (BR) at the narrow neck (NN), intertrochanter (IT), and femoral shaft (FS). Relationships of age, BMI, and years of menstruation with bone phenotypes were analyzed with the adjustment of height, age at menarche, total daily physical activity, education, smoking status, calcium tablet intake, etc. Age was associated with lower BMD, CSA, CT, SM, and higher BR (p < 0.05), which indicated a weaker bone strength at the proximal femur. BMI and years of menstruation had the positive relationships with proximal femur strength (p < 0.05). Further analyses showed that the ranges of absolute value of change slope per year, per BMI or per year of menstruation were 0.14%–1.34%, 0.20%–2.70%, and 0.16%–0.98%, respectively. These results supported that bone strength deteriorated with aging and enhanced with higher BMI and longer time of years of menstruation in Chinese postmenopausal women. PMID:26805871

  6. Shaft-Condylar Angle for surgical correction in neglected and displaced lateral humeral condyle fracture in children.

    PubMed

    Mulpruek, Pornchai; Angsanuntsukh, Chanika; Woratanarat, Patarawan; Sa-Ngasoongsong, Paphon; Tawonsawatruk, Tulyapruek; Chanplakorn, Pongsthorn

    2015-09-01

    To assess the outcome after using the Shaft-Condylar angle (SCA) as intraoperative reference for sagittal plane correction in displaced lateral humeral condyle fractures in children presented 3-weeks after injury. Ten children, with delayed presentation of a displaced lateral humeral condyle fracture and undergoing surgery during 1999-2011, were reviewed. The goal was to obtain a smooth articular surface with an intraoperative SCA of nearly 40° and nearest-anatomical carrying angle. They were allocated into two groups according to the postoperative SCA [Good-reduction group (SCA=30-50°), and Bad-reduction group (SCA<30°, >50°)] and the final outcomes were then compared. All fractures united without avascular necrosis. The Good-reduction group (n=7) showed a significant improvement in final range of motion and functional outcome compared to the Bad-reduction group (n=3) (p=0.02). However, there was no significant difference in pain, carrying angle and overall outcome between both groups. SCA is a possible intraoperative reference for sagittal alignment correction in late presented displaced lateral humeral condyle fractures.

  7. Can a semi-automated surface matching and principal axis-based algorithm accurately quantify femoral shaft fracture alignment in six degrees of freedom?

    PubMed

    Crookshank, Meghan C; Beek, Maarten; Singh, Devin; Schemitsch, Emil H; Whyne, Cari M

    2013-07-01

    Accurate alignment of femoral shaft fractures treated with intramedullary nailing remains a challenge for orthopaedic surgeons. The aim of this study is to develop and validate a cone-beam CT-based, semi-automated algorithm to quantify the malalignment in six degrees of freedom (6DOF) using a surface matching and principal axes-based approach. Complex comminuted diaphyseal fractures were created in nine cadaveric femora and cone-beam CT images were acquired (27 cases total). Scans were cropped and segmented using intensity-based thresholding, producing superior, inferior and comminution volumes. Cylinders were fit to estimate the long axes of the superior and inferior fragments. The angle and distance between the two cylindrical axes were calculated to determine flexion/extension and varus/valgus angulation and medial/lateral and anterior/posterior translations, respectively. Both surfaces were unwrapped about the cylindrical axes. Three methods of matching the unwrapped surface for determination of periaxial rotation were compared based on minimizing the distance between features. The calculated corrections were compared to the input malalignment conditions. All 6DOF were calculated to within current clinical tolerances for all but two cases. This algorithm yielded accurate quantification of malalignment of femoral shaft fractures for fracture gaps up to 60 mm, based on a single CBCT image of the fractured limb. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  8. Surgical Management of Ipsilateral Fracture of the Femur and Tibia in Adults (the Floating Knee): Postoperative Clinical, Radiological, and Functional Outcomes

    PubMed Central

    2011-01-01

    Background This study evaluated the outcomes of surgical management of ipsilateral femoral and tibial fractures in adults. Methods Fifteen patients (13 men, 2 women; mean age, 34.8 years; range, 18 to 65 years) were enrolled in this study. The fractures types were classified according to the classification by Fraser et al. as follows: type I (5), type IIa (3), IIb (4), IIc (3). Femur fractures were treated using locked intramedullary nails, plate-screws, or dynamic condylar screws, and tibia fractures were treated with an external fixator (in open fractures), or plate-screws, and locked intramedullary nailing. The mean follow-up duration was 2.2 years (range, 1.3 to 4 years). Results The extent of bony union according to the Karlstrom criteria was as follows: excellent, 8; good, 4; acceptable, 2; poor, 1. Conclusions The associated injuries and type of fracture (open, intra-articular, comminution) are prognostic factors in a floating knee. The best management of the associated injuries for good final outcome involves intramedullary nailing of both the fractures and postoperative rehabilitation. PMID:21629474

  9. Weight-bearing recommendations after operative fracture treatment-fact or fiction? Gait results with and feasibility of a dynamic, continuous pedobarography insole.

    PubMed

    Braun, Benedikt J; Veith, Nils T; Rollmann, Mika; Orth, Marcel; Fritz, Tobias; Herath, Steven C; Holstein, Jörg H; Pohlemann, Tim

    2017-08-01

    Rehabilitation after lower-extremity fractures is based on the physicians' recommendation for non-, partial-, or full weight-bearing. Clinical studies rely on this assumption, but continuous compliance or objective loading rates are unknown. The purpose of this study was to determine the compliance to weight-bearing recommendations by introducing a novel, pedobarography system continuously registering postoperative ground forces into ankle, tibial shaft and proximal femur fracture aftercare and test its feasibility for this purpose. In this prospective, observational study, a continuously measuring pedobarography insole was placed in the patients shoe during the immediate post-operative aftercare after ankle, tibial shaft and intertrochanteric femur fractures. Weight-bearing was ordered as per the institutional standard and controlled by physical therapy. The insole was retrieved after a maximum of six weeks (28 days [range 5-42 days]). Non-compliance was defined as a failure to maintain, or reach the ordered weight-bearing within 30%. Overall 30 patients were included in the study. Fourteen (47%) of the patients were compliant to the weight-bearing recommendations. Within two weeks after surgery patients deviated from the recommendation by over 50%. Sex, age and weight did not influence the performance (p > 0.05). Ankle fracture patients (partial weight-bearing) showed a significantly increased deviation from the recommendation (p = 0.01). Our study results show that, despite physical therapy training, weight-bearing compliance to recommended limits was low. Adherence to the partial weight-bearing task was further decreased over time. Uncontrolled weight-bearing recommendations should thus be viewed with caution and carefully considered as fiction. The presented insole is feasible to determine weight bearing continuously, could immediately help define real-time patient behaviour and establish realistic, individual weight-bearing recommendations.

  10. Cost effectiveness of using surgery versus skeletal traction in management of femoral shaft fractures at Thika level 5 hospital, Kenya.

    PubMed

    Opondo, Everisto; Wanzala, Peter; Makokha, Ansellimo

    2013-01-01

    A prospective quasi experimental study was undertaken at the Thika level 5 hospital. The study aimed to compare the costs of managing femoral shaft fracture by surgery as compared to skeletal traction. Sixty nine (46.6%) patients were enrolled in group A and managed surgically by intramedullary nailing while 79 (53.4%) patients were enrolled in group B and managed by skeletal traction. Exclusion criteria included patients with pathological fractures and previous femoral fractures. Data was collected by evaluation of patients in patient bills using a standardized questionnaire. The questionnaire included cost of haematological and radiological tests, bed fees, theatre fees and physiotherapy costs. The data was compiled and analyzed using SPSS version 16. Person's chi square and odds ratios were used to measure associations and risk analysis respectively. A higher proportion of patients (88.4%) in group A were hospitalized for less than one month compared to 20 patients (30.4%) in group B (p, 0.001).Total cost of treatment in group A was significantly lower than in group B. Nineteen (27.9%) patients who underwent surgery paid a total bill of Ksh 5000-7500 compared to 7(10.4%) who were treated by traction. The financial cost benefit of surgery was further complimented by better functional outcomes. The data indicates a cost advantage of managing femoral shaft fracture by surgery compared to traction. Furthermore the longer hospital stay in the traction group is associated with more malunion, limb deformity and shortening.

  11. Sex estimation by femur in modern Thai population.

    PubMed

    Monum, T; Prasitwattanseree, S; Das, S; Siriphimolwat, P; Mahakkanukrauh, P

    2017-01-01

    Sex estimation is an important step of postmortem investigation and the femur is a useful bone for sex estimation by using metric analysis method. Even though there have been a reported sex estimation method by using femur in Thais, the temporal change related to time and anthropological data need to be renewed. Thus the aim of this study is to re-evaluate sex estimation by femur in Thais. 97 adult male and 103 female femora were random chosen from Forensic osteology research center and 6 measurements were applied tend to. To compare with previous Thai data, mid shaft diameter to increase but femoral head and epicondylar breadth to stabilize and when tested previous discriminant function by vertical head diameter and epicondalar breadth, the accuracy of prediction was lower than previous report. From the new data, epicondalar breadth is the best variable for distinguishing male and female at 88.7 percent of accuracy, following by transverse and vertical head diameter at 86.7 percent and femoral neck diameter at 81.7 percent of accuracy. Multivariate discriminant analysis indicated transverse head diameter and epicondylar breadth performed highest rate of accuracy at 89.7 percent. The percent of accuracy of femur was close to previous reported sex estimation by talus and calcaneus in Thai population. Thus, for especially in case of lower limb remain, which absence of pelvis.

  12. Auckland City Hospital's ortho-geriatric service: an audit of patients aged over 65 with fractured neck of femur.

    PubMed

    Fergus, Lucy; Cutfield, Greer; Harris, Roger

    2011-06-24

    The process of care of older patients with fractured neck of femur at Auckland City Hospital has recently changed with selected patients "fast-tracked" as soon as possible postoperatively to a specialised Older People's Health (OPH) ward. The aims of this study were: to evaluate patient characteristics; to analyse process of care; to compare outcomes in those "fast-tracked" patients with those receiving usual care; and to compare this information with previous data from Auckland City Hospital and other centres in New Zealand. Prospective case record audit of patients with fractured neck of femur aged 65 years and over admitted under Orthopaedics over a 4-month period. 115 patients were audited; mean age was 84 years, 77% were female. Inpatient mortality was 5%. Twenty-four percent of patients had surgery within 24 hours of admission. Of those who did not have surgery within 24 hours, 39% were awaiting operating theatre availability. Median overall length of stay (LOS) was 27 days. Eighty-four percent of patients were transferred to Older Peoples Health. Considering all patients, 70% of those living at home pre-fracture returned home on discharge. However, only 26% of those in Rest Home returned to Rest Home. Overall, 35% of patients were discharged to a higher level of care. Forty-four percent of the group were able to walk unaided prior to hip fracture, but only 1% on discharge. Forty-three patients were "fast-tracked" to Older Peoples Health. Their median overall LOS was 23 days compared to 28 days for those receiving usual care. This was due to the shorter time in Orthopaedics. Thirty-three percent of this group went to a higher level of care on discharge compared to 35% in the group that received usual care. Many patients experience a delay to surgery for non-medical reasons. The percentage transferred to Older Peoples Health is high. Fast-tracking to Older Peoples Health shortens overall length of stay due to fewer days in Orthopaedics. Many patients require a

  13. Tangential Bicortical Locked Fixation Improves Stability in Vancouver B1 Periprosthetic Femur Fractures: A Biomechanical Study.

    PubMed

    Lewis, Gregory S; Caroom, Cyrus T; Wee, Hwabok; Jurgensmeier, Darin; Rothermel, Shane D; Bramer, Michelle A; Reid, John Spence

    2015-10-01

    The biomechanical difficulty in fixation of a Vancouver B1 periprosthetic fracture is purchase of the proximal femoral segment in the presence of the hip stem. Several newer technologies provide the ability to place bicortical locking screws tangential to the hip stem with much longer lengths of screw purchase compared with unicortical screws. This biomechanical study compares the stability of 2 of these newer constructs to previous methods. Thirty composite synthetic femurs were prepared with cemented hip stems. The distal femur segment was osteotomized, and plates were fixed proximally with either (1) cerclage cables, (2) locked unicortical screws, (3) a composite of locked screws and cables, or tangentially directed bicortical locking screws using either (4) a stainless steel locking compression plate system with a Locking Attachment Plate (Synthes) or (5) a titanium alloy Non-Contact Bridging system (Zimmer). Specimens were tested to failure in either axial or torsional quasistatic loading modes (n = 3) after 20 moderate load preconditioning cycles. Stiffness, maximum force, and failure mechanism were determined. Bicortical constructs resisted higher (by an average of at least 27%) maximum forces than the other 3 constructs in torsional loading (P < 0.05). Cables constructs exhibited lower maximum force than all other constructs, in both axial and torsional loading. The bicortical titanium construct was stiffer than the bicortical stainless steel construct in axial loading. Proximal fixation stability is likely improved with the use of bicortical locking screws as compared with traditional unicortical screws and cable techniques. In this study with a limited sample size, we found the addition of cerclage cables to unicortical screws may not offer much improvement in biomechanical stability of unstable B1 fractures.

  14. Tangential Bicortical Locked Fixation Improves Stability in Vancouver B1 Periprosthetic Femur Fractures: A Biomechanical Study

    PubMed Central

    Lewis, Gregory S.; Caroom, Cyrus T.; Wee, Hwabok; Jurgensmeier, Darin; Rothermel, Shane D.; Bramer, Michelle A.; Reid, J. Spence

    2015-01-01

    Objectives The biomechanical difficulty in fixation of a Vancouver B1 periprosthetic fracture is purchase of the proximal femoral segment in the presence of the hip stem. Several newer technologies provide the ability to place bicortical locking screws tangential to the hip stem with much longer lengths of screw purchase compared to unicortical screws. This biomechanical study compares the stability of two of these newer constructs to previous methods. Methods Thirty composite synthetic femurs were prepared with cemented hip stems. The distal femur segment was osteotomized, and plates were fixed proximally with either: (1) cerclage cables; (2) locked unicortical screws; (3) a composite of locked screws and cables; or tangentially directed bicortical locking screws using either (4) a stainless steel LCP system with a Locking Attachment Plate (Synthes), or (5) a titanium alloy NCB system (Zimmer). Specimens were tested to failure in either axial or torsional quasi-static loading modes (n = 3) after 20 moderate load pre-conditioning cycles. Stiffness, maximum force, and failure mechanism were determined. Results Bicortical constructs resisted higher (by an average of at least 27%) maximum forces than the other three constructs in torsional loading (p<0.05). Cables constructs exhibited lower maximum force than all other constructs, in both axial and torsional loading. The bicortical titanium construct was stiffer than the bicortical stainless steel construct in axial loading. Conclusions Proximal fixation stability is likely improved with the use of bicortical locking screws as compared to traditional unicortical screws and cable techniques. In this study with a limited sample size, we found the addition of cerclage cables to unicortical screws may not offer much improvement in biomechanical stability of unstable B1 fractures. PMID:26053467

  15. The Radial Bow following Square Nailing in Radius and Ulna Shaft Fractures in Adults and its Relation to Disability and Function.

    PubMed

    Dave, M B; Parmar, K D; Sachde, B A

    2016-07-01

    One of the points made against nailing in radius and ulna shaft fractures has been the loss of radial bow and its impact on function. The aims of the study were to assess the change in magnitude and location of the radial bow in radius and ulna shaft fractures treated with intramedullary square nails and to assess the impact of this change on functional outcome, patient reported disability and the range of motion of the forearm. We measured the magnitude of radial bow and its location in the operated extremity and compared it to the uninjured side in 32 adult patients treated with intramedullary square nailing for radius and ulna shaft fractures at our institute. The mean loss of magnitude of maximum radial bow was 2.18 mm which was statistically significant by both student-T test and Mann-Whitney U test with p value less than 0.01. The location of maximum radial bow shifted distally but was statistically insignificant. The magnitude of maximum radial bow had a negative correlation with DASH score that was statistically insignificant (R=- 0.22, p=0.21). It had a positive, statistically significant correlation to the extent of supination in the operated extremity (R = 0.66, p = 0.0004). A loss of up to 2mm of radial bow did not influence the functional outcome as assessed by criteria reported by Anderson et al. The magnitude of radial bow influenced the supination of the forearm but not the final disability as measured by DASH score. Intramedullary nailing did decrease the magnitude of radial bow but a reduction of up to 2mm did not influence the functional outcome.

  16. A comparative study of trochanteric and basicervical fractures of the femur treated with the Ender and McLaughlin techniques.

    PubMed

    Indemini, E; Clerico, P; Fenoglio, E; Mariotti, U

    1982-09-01

    Endomedullary nailing as proposed by Ender is an important alternative in the treatment of trochanteric and basicervical fractures of the femur (Amici et al., 1980; Carret et al., 1980; Ender, 1970; Kempf et al., 1979; Zinghi et al., 1979). Rush's concept (Eiffel Tower, for the distal epiphysis) is reproposed with some variations and transposed to the femoral neck. The aim of the operation differs from that of the nail and plate technique in that, instead of trying to achieve anatomical reconstruction, an immediate functional by-pass of the fractured part is attempted. After using this technique for three years, we compared the old method, which we had not abandoned, the McLaughlin nail and plate, with the new Ender nail.

  17. Treatment of open tibial shaft fracture with soft tissue and bone defect caused by aircraft bomb--case report.

    PubMed

    Golubović, Zoran; Vidić, Goran; Trenkić, Srbobran; Vukasinović, Zoran; Lesić, Aleksandar; Stojiljković, Predrag; Stevanović, Goran; Golubović, Ivan; Visnjić, Aleksandar; Najman, Stevo

    2010-01-01

    Aircraft bombs can cause severe orthopaedic injuries. Tibia shaft fractures caused by aircraft bombs are mostly comminuted and followed by bone defects, which makes the healing process extremely difficult and prone to numerous complications. The goal of this paper is to present the method of treatment and the end results of treatment of a serious open tibial fracture with soft and bone tissue defects resulting from aircraft bomb shrapnel wounds. A 26-year-old patient presented with a tibial fracture as the result of a cluster bomb shrapnel wound. He was treated applying the method of external bone fixation done two days after wounding, as well as of early coverage of the lower leg soft tissue defects done on the tenth day after the external fixation of the fracture. The external fixator was removed after five months, whereas the treatment was continued by means of functional plaster cast for another two months. The final functional result was good. Radical wound debridement, external bone fixation of the fracture, and early reconstruction of any soft tissue and bone defects are the main elements of the treatment of serious fractures.

  18. Fat embolism syndrome in femoral shaft fractures: does the initial treatment make a difference?

    PubMed

    Silva, Jânio José Alves Bezerra; Diana, Diogo de Almeida; Salas, Victor Eduardo Roman; Zamboni, Caio; Hungria Neto, José Soares; Christian, Ralph Walter

    2017-01-01

    To identify the risk factors correlated with the initial treatment performed. This is a retrospective study involving a total of 272 patients diagnosed with femoral shaft fractures. Of the patients, 14% were kept at rest until the surgical treatment, 52% underwent external fixation, 10% received immediate definitive treatment, and 23% remained in skeletal traction (23%) until definitive treatment. There were six cases of fat embolism syndrome (FES), which showed that polytrauma is the main risk factor for its development and that initial therapy was not important. Polytrauma patients have a greater chance of developing FES and there was no influence from the initial treatment.

  19. Auckland City Hospital's Ortho-Geriatric Service: an audit of patients aged over 65 with fractured neck of femur.

    PubMed

    Wimalasena, Bodhi; Harris, Roger

    2016-07-01

    The aims of this audit were to collect the Minimum Data Set outlined by the Australia New Zealand Hip Fracture Registry (ANZHFR), assess patient characteristics, analyse process of care, and evaluate how this compares to NICE guidelines for hip fracture care, as well as to Auckland Hospital data from 2007. Retrospective case record audit of patients with fractured neck of femur aged 65 years and over admitted under Orthopaedics over a 4-month period in 2013. Ninety-one patients were audited; mean age was 83 years, 68% were female. Both inpatient and 30-day mortality was 5%. 120-day mortality was 15%. Seventy-six percent of patients were admitted from ED within the national health target prescribed period of 6 hours. Only one patient was treated non-surgically. Eighty-six percent had surgery within 48 hours of admission. Eighty-two percent of patients had rehabilitation and treatment by Older People's Health. Of those living at home pre-fracture, 76% returned home on discharge. Thirty-seven percent of patients were able to walk unaided prior to hip fracture, but only 1% on discharge. Average overall length of stay was 22 days. Bisphosphonates were prescribed for 56% of patients. Compared to 2007, Auckland City Hospital has demonstrated a significant improvement in the rate of provision of timely surgery for hip fracture patients. Most patients are receiving the guideline recommended fracture-specific surgical interventions. The assessment and treatment of osteoporosis needs further attention.

  20. MANAGEMENT OF ENDOCRINE DISEASE: Atypical femoral fractures: risks and benefits of long-term treatment of osteoporosis with anti-resorptive therapy.

    PubMed

    Adler, Robert A

    2018-03-01

    Modern osteoporosis treatment began in the mid-1990s with the approval of amino-bisphosphonates, anti-resorptive agents that have been shown to decrease osteoporotic fracture risk by about half. In 2005, the first cases of atypical femoral fractures (AFF), occurring in the shaft of the femur, were reported. Since then, more cases have been found, leading to great concern among patients and a dramatic decrease in bisphosphonate prescribing. The pathogenesis and incidence of AFF are reviewed herein. Management and an approach to prevention or early detection of AFF are also provided. Denosumab, a more recently approved anti-resorptive medication has also been associated with AFF. Long-term management of osteoporosis and prevention of fracture are challenging in light of this serious but uncommon side effect, yet with an aging population osteoporotic fracture is destined to increase in frequency. © 2018 European Society of Endocrinology.

  1. The management of humeral shaft fractures with associated radial nerve palsy: a review of 117 cases.

    PubMed

    Bumbasirević, Marko; Lesić, Aleksandar; Bumbasirević, Vesna; Cobeljić, Goran; Milosević, Ivan; Atkinson, Henry Dushan E

    2010-04-01

    This single center retrospective study reviews the management and outcomes of 117 consecutive patients with humeral shaft fractures and associated radial nerve palsy (RNP) treated over a 20-year period (1986-2006). A total of 101 fractures were managed conservatively and 16 fractures underwent external fixation for poor bony alignment. Sixteen grade 1 and 2 open fractures underwent wound toileting alone. No patients underwent initial radial nerve exploration or opening of the fracture sites. All patients achieved clinical and radiological bony union at a mean of 8 weeks (range 7-12 weeks). There were no complications or pin tract infections in the operated patients. A total of 111 cases had initial spontaneous RNP recovery at a mean of 6 weeks (range 3-24 weeks) with full RNP recovery at a mean of 17 weeks (range 3-70 weeks) post-injury. Fourteen patients had no clinical/EMG signs of nerve activity at 12 weeks and 6 subsequently failed to regain any radial nerve recovery; 2 had late explorations and the lacerated nerves underwent sural nerve cable neurorraphy; and 4 patients underwent delayed tendon transposition 2-3 years after initial injury, with good/excellent functional outcomes. Humeral fractures with associated RNP may be treated expectantly. With low rates of humeral nonunion, 95% spontaneous nerve recovery in closed fractures and 94% in grade 1 and 2 open fractures, one has the opportunity of waiting. If at 10-12 weeks there are no clinical/EMG signs of recovery, then nerve exploration/secondary reconstruction is indicated. Late tendon transfers may also give good/excellent functional results.

  2. [Current status of surgical technique for unreamed nailing of tibial shaft fractures with the UTN (unreamed tibia nail)].

    PubMed

    Krettek, C; Schandelmaier, P; Rudolf, J; Tscherne, H

    1994-11-01

    Nailing technique has changed in recent years in some important aspects which are not limited to the omitted reaming procedure. These changes concern patient positioning, reduction technique, the use of temporary stabilizers such as the 'Pinless', and determination of implant length and diameter. Approach and exposure techniques have been modified to new, less invasive procedures, in order to fulfill technical, functional and aesthetic requirements. Techniques and tricks have been developed for avoidance of fragment diastasis and axial and torsional malalignment. Finally, simple algorithms are described for the management of large bone defects, bilateral tibia shaft or ipsilateral femoral shaft fractures, number and location of locking bolts, the 'when and how' of patient mobilization and load bearing, and primary and secondary dynamization. These algorithms, techniques and procedures were developed in a series of 152 tibia shafts, which were stabilized with the AO unreamed tibia nail (UTN) in a prospective study between March 1989 and June 1994. Of these, 75 cases with a mean follow-up of 19.4 +/- 6.3 (range 11-37) months after trauma were reviewed. Fractures were classified according to Müller (1990): 14 type A, 37 type B and 24 type C. Closed soft tissue damage was categorized according to our classification: C0/1, n = 5; C2, n = 12; C3, n = 9 (Tscherne 1982). Among 49 open fractures 8 were OI, 18 OII, 10 OIIIA and 13 OIIIB (Gustilo 1976). The main minor intraoperative complication was drill bit breakage (n = 10), most frequently at the proximal locking holes. The main postoperative complication was breakage of locking bolts (n = 16), mainly between weeks 6 and 20. Minor secondary reinterventions were, in most cases, secondary dynamization under local anaesthesia. Major reintervention were: soft tissue reconstructions (n = 5), isolated cancellous bone graft (n = 6), and change of treatment (n = 12). There were nine changes to a reamed nail, two changes, in very

  3. Mechanical Strength of the Proximal Femur After Arthroscopic Osteochondroplasty for Femoroacetabular Impingement: Finite Element Analysis and 3-Dimensional Image Analysis.

    PubMed

    Oba, Masatoshi; Kobayashi, Naomi; Inaba, Yutaka; Choe, Hyonmin; Ike, Hiroyuki; Kubota, So; Saito, Tomoyuki

    2018-06-21

    To examine the influence of femoral neck resection on the mechanical strength of the proximal femur in actual surgery. Eighteen subjects who received arthroscopic cam resection for cam-type femoroacetabular impingement (FAI) were included. Finite element analyses (FEAs) were performed to calculate changes in simulative fracture load between pre- and postoperative femur models. The finite element femur models were constructed from computed tomographic images; thus, the models represented the shape of the original femur, including the bone resection site. Three-dimensional image analysis of the bone resection site was performed to identify morphometric factors that affect strength in the postoperative femur model. Four oblique sagittal planes running perpendicular to the femoral neck axis were used as reference planes to measure the bone resection site. At the transcervical reference plane, both the bone resection depth and the cross-sectional area at the resection site correlated strongly with postoperative changes in the simulated fracture load (R 2  = 0.6, P = .0001). However, only resection depth was significantly correlated with the simulated fracture load at the reference plane for the head-neck junction. The resected bone volume did not correlate with the postoperative changes in the simulated fracture load. The results of our FEA suggest that the bone resection depth measured at the head-neck junction and transcervical reference plane correlates with fracture risk after osteochondroplasty. By contrast, bone resection at more proximal areas did not have a significant effect on the postoperative femur model strength in our FEA. The total volume of resected bone was also not significantly correlated with postoperative changes in femur model strength. This biomechanical study using FEA suggest that there is a risk of femoral neck fracture after arthroscopic cam resection, particularly when the resected lesion is located distally. Copyright © 2018 Arthroscopy

  4. Lateral gastrocnemius myocutaneous flap transposition to the midlateral femur: extending the arc of rotation.

    PubMed

    Agarwal, Rishi Raj; Broder, Kevin; Kulidjian, Anna; Bodor, Richard

    2014-05-01

    We report the successful use of an extended lateral gastrocnemius myocutaneous flap for coverage of the midlateral femur using successive delayed elevations. A 62-year-old man underwent wide resection of a liposarcoma of the right anterior thigh with free flap reconstruction and subsequent radiation therapy 10 years before. Four years later, the patient fractured his irradiated femur and was treated with a retrograde intramedullary nail, which subsequently became infected, causing osteomyelitis of the distal femur, septic arthritis of the knee joint, and nonunion of his pathologic fracture. Although advised by numerous surgeons to undergo above-knee amputation, we offered our motivated patient a multidisciplinary approach to clear his infection and pathology; implanted new orthopedic hardware; performed delayed flap reconstruction; and rehabilitated him back to painless, unassisted ambulation. The extended lateral gastrocnemius myocutaneous flap used provided perfused soft tissues and durable coverage for the patient's exposed orthopedic hardware of the midlateral femur, 14 cm above the joint line of the knee. By using this flap to cover a femur defect well above published heights, our patient avoided amputation after years of worsening incapacitation.

  5. Rare stress fracture: longitudinal fracture of the femur.

    PubMed

    Pérez González, M; Velázquez Fragua, P; López Miralles, E; Abad Moretón, M M

    42-year-old man with pain in the posterolateral region of the right knee that began while he was running. Initially, it was diagnosed by magnetic resonance (MR) as a possible aggressive process (osteosarcoma or Ewing's sarcoma) but with computed tomography it was noted a cortical hypodense linear longitudinal image with a continuous, homogeneous and solid periosteal reaction without clear soft tissue mass that in this patient suggest a longitudinal distal femoral fatigue stress fracture. This type of fracture at this location is very rare. Stress fractures are entities that can be confused with an agressive process. MR iscurrently the most sensitive and specific imaging method for its diagnosis. Copyright © 2017 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  6. Elastic-plastic fracture mechanics of compact bone

    NASA Astrophysics Data System (ADS)

    Yan, Jiahau

    Bone is a composite composed mainly of organics, minerals and water. Most studies on the fracture toughness of bone have been conducted at room temperature. Considering that the body temperature of animals is higher than room temperature, and that bone has a high volumetric percentage of organics (generally, 35--50%), the effect of temperature on fracture toughness of bone should be studied. Single-edged V-shaped notched (SEVN) specimens were prepared to measure the fracture toughness of bovine femur and manatee rib in water at 0, 10, 23, 37 and 50°C. The fracture toughness of bovine femur and manatee rib were found to decrease from 7.0 to 4.3 MPa·m1/2 and from 5.5 to 4.1 MPa·m1/2, respectively, over a temperature range of 50°C. The decreases were attributed to inability of the organics to sustain greater stresses at higher temperatures. We studied the effects of water and organics on fracture toughness of bone using water-free and organics-free SEVN specimens at 23°C. Water-free and organics-free specimens were obtained by placing fresh bone specimen in a furnace at different temperatures. Water and organics significantly affected the fracture toughness of bone. Fracture toughness of the water-free specimens was 44.7% (bovine femur) and 32.4% (manatee rib) less than that of fresh-bone specimens. Fracture toughness of the organics-free specimens was 92.7% (bovine femur) and 91.5% (manatee rib) less than that of fresh bone specimens. Linear Elastic Fracture Mechanics (LEFM) is widely used to study bone. However, bone often has small to moderate scale yielding during testing. We used J integral, an elastic-plastic fracture-mechanics parameter, to study the fracture process of bone. The J integral of bovine femur increased from 6.3 KJ/mm2 at 23°C to 6.7 KJ/mm2 at 37°C. Although the fracture toughness of bovine bone decreases as the temperature increases, the J integral results show a contrary trend. The energy spent in advancing the crack beyond the linear

  7. Decreased muscle strength is associated with impaired long-term functional outcome after intramedullary nailing of femoral shaft fracture.

    PubMed

    Larsen, P; Elsoe, R; Graven-Nielsen, T; Laessoe, U; Rasmussen, S

    2015-12-01

    To examine the long-term outcome after intramedullary nailing of femoral diaphysial fractures measured as disease-specific patient reported function, walking ability, muscle strength, pain and quality of life (QOL). Cross-sectional study. Retrospective review and follow-up with clinical examination of 48 patients treated with intramedullary nailing after femoral shaft fracture between 2007 and 2010. The patients underwent a clinical examination and assessment of walking ability, maximal muscle strength during knee flexion and extension and hip abduction. Hip disability and Osteoarthritis Outcome Score (HOOS) and questionnaire evaluating QOL (Eq5D-5L) were completed by patients. Fourty-eight patients agreed to participate. Mean time for follow-up was 4.7 years. The mean HOOS scores were 84.9 (Pain), 86.6 (ADL), 85.0 (Symptoms), 72.6 (QOL), and 69.1 (Sport). The mean muscle strength of knee flexion with the injured leg (226.0 N) was significantly lower then knee flexion with the non-injured leg (259.5 N, P < 0.0001). Likewise for knee extension (335.2 vs 406.4 N, P < 0.001) and hip abduction (129.2 vs 156.0 N, P < 0.001). Significant association between HOOS and an increase in the difference in muscle strength were observed as well as between worse HOOS outcome and increasing body mass index. This study showed that decreased muscle strength for knee flexion, knee extension and hip abduction was associated with worse long-term functional outcome measured with a disease-specific questionnaire (HOOS) after intramedullary nailing of femoral shaft fracture.

  8. Sex-specific quantitative trait loci contribute to normal variation in bone structure at the proximal femur in men

    PubMed Central

    Peacock, Munro; Koller, Daniel L.; Lai, Dongbing; Hui, Siu; Foroud, Tatiana; Econs, Michael J.

    2006-01-01

    Bone structure is an important determinant of osteoporotic fracture. In women bone structure is highly heritable and several quantitative trait loci (QTL) have been reported. There are few comparable data in men. This study in men aimed at establishing the heritability of bone structure at the proximal femur, identifying QTL contributing to normal variation in bone structure, and determining which QTL might be sex-specific. Bone structure at the proximal femur was measured in 205 pairs of brothers age 18–61. Heritability was calculated and linkage analysis performed on phenotypes at the proximal femur. Heritability estimates ranged from 0.99 to 0.39. A genome wide scan identified suggestive QTL (LOD>2.2) for femoral shaft width on chromosome 14q (LOD=2.69 at position 99cM), calcar femorale at chromosome 2p (LOD= 3.97 at position 194cM) and at the X chromosome (LOD= 3.01 at position 77cM), femoral neck width on chromosome 5p (LOD=2.28 at position 0 cM), femoral head width on chromosome 11q (LOD=2.30 at position 131 cM) and 15q (LOD=3.11 at position 90 cM), and pelvic axis length on chromosome 4q (LOD= 4.16 at 99cM) and 17q (LOD=2.80 at position 112 cM). Comparison with published data in 437 pairs of premenopausal sisters from the same geographical region suggested that 3 of the 7 autosomal QTL were male-specific. This study demonstrates that bone structure at the proximal femur in healthy men is highly heritable. The occurrence of sex-specific genes in humans for bone structure has important implications for the pathogenesis and treatment of osteoporosis. PMID:16046210

  9. Antomy of the Proximal Femur -geometry and architecture. Morphologic investigation and literature review.

    PubMed

    Glinkowski, Wojciech; Ciszek, Bogdan

    2002-04-30

    Material and methods. To analyze morphology and endosteal anatomy of the proximal ends of the femur of 40 cadaver femora were x-rayed, dissected and measured. Various variables including trabecular pattern, calcar size, and cortical bone were measured and correlated. Observations were compared to literature concerns the various aspects of anatomy of the proximal femur.
    Results. One must recognize that much of the information that we gather in every day practice is two dimensional, namely, x-rays of the hip. Morphological data with three-dimensional perspective demonstrate internal architecture of proximal femur including calcar femorale. Authors pointed out lower values of neck shaft angle than observed in other examined populations.
    Conclusions. They found that topographic and angular position of calcar femorale depends on anteversion angle. Shadow of the calcar on X-ray of the femur in Lauenstein's view may become invisible in some cases what is correlated to its real dimension. Calcar femorale as a anatomical structure has no strict topographic coincidence with "calcar resorption" observed in some total hip replacements.

  10. Treatment of femur fractures in young children: a multicenter comparison of flexible intramedullary nails to spica casting in young children aged 2 to 6 years.

    PubMed

    Heffernan, Michael J; Gordon, J Eric; Sabatini, Coleen S; Keeler, Kathryn A; Lehmann, Charles L; O'Donnell, June C; Seehausen, Derek A; Luhmann, Scott J; Arkader, Alexandre

    2015-03-01

    Spica casting is the standard of care for femur fractures in children up to 6 years of age. The indications for surgery are controversial. We sought to compare immediate spica casting (Spica) and flexible intramedullary nailing [titanium elastic nailing (TEN)] in a group of children ages 2 to 6 years. We hypothesized that young children can be successfully treated with flexible nails, resulting in faster return to ambulation and an equivalent complication rate when compared with spica casting. This was a multicenter retrospective review of 215 patients, 141 treated with immediate spica casting, and 74 treated with elastic nails. Patient demographics, fracture characteristics, mechanism of injury, associated injuries, outcomes, and complications were recorded and compared between the 2 groups. Patients in the elastic nailing group were more likely to be injured as a pedestrian struck by an automobile (Spica 8% vs. TEN 26%, P=0.001), and had increased rates of associated injuries (P<0.001). Time to fracture union was similar between the 2 groups (P=0.652). The TEN group had shorter time to independent ambulation (Spica 51±14 vs. TEN 29±14 d, P<0.001) and return to full activities (Spica 87±19 vs. TEN 74±28 d, P=0.023). TEN is a reasonable option for treatment of femur fractures in young children when compared with spica casting with shorter time to independent ambulation and full activities. Fractures associated with a high-energy mechanism are especially appropriate for consideration of treatment with TEN. Level III, this was a retrospective comparative study.

  11. Treatment of close-range, low-velocity gunshot fractures of tibia and femur diaphysis with consecutive compression-distraction technique: a report of 11 cases.

    PubMed

    Ateşalp, A Sabri; Kömürcü, Mahmut; Demiralp, Bahtiyar; Bek, Dogan; Oğuz, Erbil; Yanmiş, Ibrahim

    2004-01-01

    Lower extremity injuries secondary to close-range, low-velocity gunshot wounds are frequently seen in both civilian and military populations. A close-range, low-velocity injury produces high energy and often results in comminuted and complicated fractures with significant morbidity. In this study, four femoral, four tibial, and three combined tibia and fibular comminuted diaphyseal fractures secondary to close-range, low-velocity gunshot wounds in 11 military personnel were treated with debridement followed by compression-distraction lengthening using a circular external fixator frame. Fracture union was obtained in all without significant major complications. Fracture consolidation occurred at a mean of 3.5 months. At follow-up of 46.8 months, there were no delayed unions, nonunions, or malunions. Minor complications included four pin-tract infections and knee flexion limitation in two femur fractures. Osteomyelitis and deep soft tissue infection were not observed. This technique provided an alternative to casting, open reduction internal fixation, or intermedullary fixation with an acceptable complication rate.

  12. A method for accounting for test fixture compliance when estimating proximal femur stiffness.

    PubMed

    Rossman, Timothy; Dragomir-Daescu, Dan

    2016-09-06

    Fracture testing of cadaveric femora to obtain strength and stiffness information is an active area of research in developing tools for diagnostic prediction of bone strength. These measurements are often used in the estimation and validation of companion finite element models constructed from the femora CT scan data, therefore, the accuracy of the data is of paramount importance. However, experimental stiffness calculated from force-displacement data has largely been ignored by most researchers due to inherent error in the differential displacement measurement obtained when not accounting for testing apparatus compliance. However, having such information is necessary for validation of computational models. Even in the few cases when fixture compliance was considered the measurements showed large lab-to-lab variation due to lack of standardization in fixture design. We examined the compliance of our in-house designed cadaveric femur test fixture to determine the errors we could expect when calculating stiffness from the collected experimental force-displacement data and determined the stiffness of the test fixture to be more than 10 times the stiffness of the stiffest femur in a sample of 44 femora. When correcting the apparent femur stiffness derived from the original data, we found that the largest stiffness was underestimated by about 10%. The study confirmed that considering test fixture compliance is a necessary step in improving the accuracy of fracture test data for characterizing femur stiffness, and highlighted the need for test fixture design standardization for proximal femur fracture testing. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Fragile external phenotype of modern human proximal femur in comparison with medieval bone.

    PubMed

    Sievänen, Harri; Józsa, László; Pap, Ildiko; Järvinen, Markku; Järvinen, Tero A; Kannus, Pekka; Järvinen, Teppo L

    2007-04-01

    Proximal femur macroanatomy of 118 medieval and 67 contemporary adults, 84 contemporary elderly, and 48 contemporary hip fracture cases was evaluated. Within approximately 1000 years, the femoral neck axis has become longer, and its cross-section has become proportionally smaller and more oval in shape. These changes in the present external phenotype alone account for approximately 50% higher fall-induced stress compared with the medieval situation. Bones, as whole skeletal structures, adapt to mechanical stresses they customarily experience. Because the present, mechanized lifestyle apparently deprives our skeletons of vigorous, habitual physical exertion, we studied whether the proximal femur phenotype has evolved vulnerable to fragility fractures by time. Proximal femur macroanatomy of 118 medieval and 67 contemporary adults, 84 contemporary elderly, and 48 contemporary hip fracture cases was evaluated. Using direct measurements of external bone dimensions and geometric properties, we estimated the fall-induced stress as an index of hip fragility. Within approximately 1000 years, the femoral axis length has become substantially longer (analysis of covariance, body height adjusted, p < 0.001), whereas the neck circumference has not increased. The macroanatomy was found similar between the contemporary adult and elderly groups. In hip fracture cases, however, the femoral axis length was further lengthened (p < 0.001), but the circumference was somewhat smaller (p = 0.001). Consequently, the estimated fall-induced stress can be approximately 1.5-fold today compared with the medieval times (p < 0.001), and the secular trend seemed to be worse in women (sex-time interaction, p = 0.001). The modern, relatively slender phenotype of the proximal femur alone seems to increase the fall-induced stress considerably, and when this phenotype coincides the osteoporotic, internally deteriorated femoral neck structure, fracture risk is imminent. This mechanically compromised

  14. The outcome of unstable proximal femoral fracture treated with reverse LISS plates.

    PubMed

    Lin, Shih-Jie; Huang, Kuo-Chin; Chuang, Po-Yao; Lee, Chien-Yin; Huang, Tsan-Wen; Lee, Mel S; Hsu, Robert Wen-Wei

    2016-10-01

    The Russel-Taylor type 2B fractures compromised the trochanteric region and medial buttress of proximal femur. This fracture pattern limits the choice of implants and raises the risk of adverse outcomes. We aimed to (i) determine the outcome of Russel-Taylor type 2B fractures treated using reverse less invasive stabilization system plates (LISS-DF) and to (ii) learn what factors affected outcomes after osteosynthesis with reverse LISS plates. A retrospective study SETTING: The study was conducted at a Level III trauma center in Taiwan. Twenty-five consecutive patients presenting with a Russel-Taylor type 2B fracture were enrolled. All cases were treated with reverse LISS plates. A Modified Radiographic Union Scale for Femur (RUSF), Radiographic parameters, functional scores, and complications were assessed. Union occurred in 21 cases at an average of 18.8 weeks. The average immediate postoperative neck-shaft angle was 130° (range: 122-135°) compared with 139° (range: 135-141°, p=0.05) on the contralateral side. Two cases had complications of proximal screws cutting out and two cases had broken implants. Finally, all 4 cases required repeated surgeries (16%). Malunion occurred in 4 patients and early mechanical failure (proximal screws cut out) occurred in 2. There was a significant difference in the purchase index of the proximal screws between cases with redisplacement and those without (26.4mm and 98.6mm, p=0.01). The use of reverse LISS plate appeared to be an alternative procedure for the specific pattern in the present study. We recommend using this reverse locking plate to treat unstable proximal femoral fractures with meticulous techniques of placing plates. Adequate purchase of the proximal locking screws might decrease the risks of complications. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Femoral neck-shaft angle in extra-capsular proximal femoral fracture fixation; does it make a TAD of difference?

    PubMed

    Walton, N P; Wynn-Jones, H; Ward, M S; Wimhurst, J A

    2005-11-01

    The effect of femoral neck-shaft angle and implant type on the accuracy of lag screw placement in extra-capsular proximal femoral fracture fixation was investigated. Radiographs of all extra-capsular proximal femoral fractures seen in one unit over 18 months were reviewed. Of 399 cases, 307 (237 female, 70 male) were included in the study as they had no contra-lateral proximal femoral metal work. Femoral neck-shaft angle (NSA) of the uninjured hip and magnification adjusted tip-apex distance (TAD) of femoral head lag screw were measured. Type of fixation implant was 135 degrees classic hip screw (CHS) (n=144) or 130 degrees intra-medullary hip screw (IMHS) (n=163). Mean contra-lateral NSA was 130.2 degrees (112.9--148 degrees ) and 64 patients (58 female, 6 male) had a NSA <125 degrees . Mean adjusted TAD was 18.7 mm (5.8--43.8mm) and 88.9% of cases had a TAD of less than 25 mm. TAD values were significantly greater using an IMHS if NSA was <125 degrees than if NSA was >125 degrees (p=0.028). This was not the case with the CHS. The use of the 130 degrees -IMHS in patients with a NSA <125 degrees leads to poorer lag screw placement than if NSA >125 degrees and caution is advocated when using this device in such cases.

  16. Additional Tension Screws Improve Stability in Elastic Stable Intramedullary Nailing: Biomechanical Analysis of a Femur Spiral Fracture Model.

    PubMed

    Zachert, Gregor; Rapp, Marion; Eggert, Rebecca; Schulze-Hessing, Maaike; Gros, Nina; Stratmann, Christina; Wendlandt, Robert; Kaiser, Martin M

    2015-08-01

    For pediatric femoral shaft fractures, elastic stable intramedullary nailing (ESIN) is an accepted method of treatment. But problems regarding stability with shortening or axial deviation are well known in complex fracture types and heavier children. Biomechanical in vitro testing was performed to determine whether two modified osteosyntheses with an additional tension screw fixation or screw fixation alone without nails could significantly improve the stability in comparison to classical ESIN. A total of 24 synthetic adolescent-sized femoral bone models (Sawbones, 4th generation; Vashon, Washington, United States) with an identical spiral fracture (length 100 mm) were used. All grafts underwent retrograde fixation with two C-shaped steel nails (2C). Of the 24, 8 osteosyntheses were supported by one additional tension screw (2C1S) and another 8 by two screws (2S) in which the intramedullary nails were removed before testing. Each configuration underwent biomechanical testing in 4-point bending, external rotation (ER) and internal rotation (IR). Furthermore, the modifications were tested in axial physiological 9 degrees position for shifting and dynamic compression as well as dynamic load. Both screw configurations (2C1S and 2S) demonstrated a significantly higher stability in comparison to the 2C configuration in 4-point bending (anterior-posterior, 0.95 Nm/mm [2C] < 8.41 Nm/mm [2C1S] and 15.12 Nm/mm [2S]; posterior-anterior, 8.55 Nm/mm [2C] < 12.65 Nm/mm [2C1S] and 17.54 Nm/mm [2S]; latero-medial, 1.17 Nm/mm [2C] < 5.53 Nm/mm [2C1S] and 9.15 Nm/mm [2S]; medio-lateral, 1.74 Nm/mm [2C] < 9.69 Nm/mm [2C1S] and 12.20 Nm [2S]; all p < 0.001) and during torsion (ER, 0.61 Nm/degree [2C] < 4.10 Nm/degree [2C1S] and 9.29 Nm/degree [2S]; IR, 0.18 Nm/degree [2C] < 6.17 Nm/degree [2C1S] and 10.61 Nm/degree [2S]; all p < 0.001]. The shifting in compression in 9 degrees position was only slightly influenced. The comparison of 2S versus 2C1S showed more stability for

  17. Influence of ethanol on stiffness, toughness, and ductility of femurs of rats.

    PubMed

    Kusy, R P; Hirsch, P F; Peng, T C

    1989-04-01

    Recently, we reported that the ingestion of alcohol in rats reduced the mechanical strength of femurs. Our results showed that, as the dose exceeded 0.012 g of ethanol per gram of body weight, a significant (p less than 0.001) loss of "strength" occurred that was independent of sex according to the relationship, Strength (N) = 140.4 - 6003 dose (g/g). In the present effort, the same flexure tests were reevaluated to include the parameters of stiffness, toughness, and ductility. These latest results confirm that the femurs of rats fed an ethanol liquid diet for 4 weeks are not only weaker but also more compliant and less energy absorbing. Although the femurs of rats fed ethanol are more ductile, the bones are more prone to fracture in fatigue and impact circumstances as well as under simple loading situations. The rat may be an appropriate model to study the mechanisms that lead to the higher incidence of fractures in the alcoholic human.

  18. Return to sport following clavicle fractures: a systematic review.

    PubMed

    Robertson, G A J; Wood, A M

    2016-09-01

    This review aims to provide information on the return rates and return times to sport following clavicle fractures. A systematic search of Medline, EMBASE, CINAHAL, Cochrane, Web of Science, PEDro, SPORTDiscus, Scopus and Google Scholar was performed using the keywords 'clavicle', 'clavicular', 'fractures', 'athletes', 'sports', 'non-operative', 'conservative', 'operative', 'return to sport'. Twenty-three studies were included: 10 reported on mid-shaft fractures, 14 on lateral fractures. The management principles for athletic patients were to attempt non-operative management for undisplaced fractures to undertake operative intervention for displaced lateral fractures and to recommend operative intervention for displaced mid-shaft fractures. The optimal surgical modality for mid-shaft and lateral clavicle fractures. Operative management of displaced mid-shaft fractures offers improved return rates and times to sport compared to non-operative management. Suture fixation and non-acromio-clavicular joint (ACJ)-spanning plate fixation of displaced lateral fractures show promising results. Future prospective studies should aim to establish the optimal treatment modalities for clavicle fractures. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  19. Relationships of bone characteristics in MYO9B deficient femurs.

    PubMed

    Kim, Do-Gyoon; Jeong, Yong-Hoon; McMichael, Brooke K; Bähler, Martin; Bodnyk, Kyle; Sedlar, Ryan; Lee, Beth S

    2018-08-01

    The objective of this study was to examine relationships among a variety of bone characteristics, including volumetric, mineral density, geometric, dynamic mechanical analysis, and static fracture mechanical properties. As MYO9B is an unconventional myosin in bone cells responsible for normal skeletal growth, bone characteristics of wild-type (WT), heterozygous (HET), and MYO9B knockout (KO) mice groups were compared as an animal model to express different bone quantity and quality. Forty-five sex-matched 12-week-old mice were used in this study. After euthanization, femurs were isolated and scanned using microcomputed tomography (micro-CT) to assess bone volumetric, tissue mineral density (TMD), and geometric parameters. Then, a non-destructive dynamic mechanical analysis (DMA) was performed by applying oscillatory bending displacement on the femur. Finally, the same femur was subject to static fracture testing. KO group had significantly lower length, bone mineral density (BMD), bone mass and volume, dynamic and static stiffness, and strength than WT and HET groups (p < 0.019). On the other hand, TMD parameters of KO group were comparable with those of WT group. HET group showed volumetric, geometric, and mechanical properties similar to WT group, but had lower TMD (p < 0.014). Non-destructive micro-CT and DMA parameters had significant positive correlations with strength (p < 0.015) without combined effect of groups and sex on the correlations (p > 0.077). This comprehensive characterization provides a better understanding of interactive behavior between the tissue- and organ-level of the same femur. The current findings elucidate that MYO9B is responsible for controlling bone volume to determine the growth rate and fracture risk of bone. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Anatomical evaluation and stress distribution of intact canine femur.

    PubMed

    Verim, Ozgur; Tasgetiren, Suleyman; Er, Mehmet S; Ozdemir, Vural; Yuran, Ahmet F

    2013-03-01

    In the biomedical field, three-dimensional (3D) modeling and analysis of bones and tissues has steadily gained in importance. The aim of this study was to produce more accurate 3D models of the canine femur derived from computed tomography (CT) data by using several modeling software programs and two different methods. The accuracy of the analysis depends on the modeling process and the right boundary conditions. Solidworks, Rapidform, Inventor, and 3DsMax software programs were used to create 3D models. Data derived from CT were converted into 3D models using two different methods: in the first, 3D models were generated using boundary lines, while in the second, 3D models were generated using point clouds. Stress analyses in the models were made by ANSYS v12, also considering any muscle forces acting on the canine femur. When stress values and statistical values were taken into consideration, more accurate models were obtained with the point cloud method. It was found that the maximum von Mises stress on the canine femur shaft was 34.8 MPa. Stress and accuracy values were obtained from the model formed using the Rapidform software. The values obtained were similar to those in other studies in the literature. Copyright © 2012 John Wiley & Sons, Ltd.

  1. Fat Embolism Among Patients with Hip and Long Bone Fractures in Albania

    PubMed Central

    Hysa, Elida

    2012-01-01

    Objective: The aim of this study was to assess the incidence and the effectiveness of treatment of fat embolism in patients with hip and long bone fractures (femur and tibia) in Albania. Methods: 229 patients (68% men) with combined hip and long bone fractures (femur and tibia) hospitalized at the Orthopedics-Traumatology Services of the University Center “Mother Teresa” during 2004-2006 were included in the study. Patients were classified into three groups based on astrupogram data: PaO2<60mmHg, 65mmHg75mmHg. Chi square test was used to compare fracture differences between men and women and the effectiveness of combined use of metilprednisolon and anticoagulants vs. anticoagulants alone. Results: Poly traumas combined with femur fracture were more frequent in 2005. These combined poly traumas combined were more frequent among men than women (P<0.001). Remarkably, femur fractures were more frequent among men than women (9:1). Coli femur fractures peaked in the age-group 76-85 years. In general, poly traumas were less frequent in the older age groups, with a peak between 36-55 years, being more frequent among men, but the difference was not statistically significant. Fractures of coli femur and those of tibia were more frequent in 2006, while in 2004 femur fractures were more frequent. In almost all age groups fractures of coli femur were more frequent, followed by fractures of femur and tibia. In general, poly traumas were more frequent among men than women, ranging from 6:1 for fractures of femur to 2:1 for tibia fractures. The incidence of fat embolism ranged from 4.9% to 8.9% for the period 2004-2006. Among fat embolism patients, 100% of them had tachycardia, 88.2% had petechia, 84% tachipnea, 23.5% cyanosis and blood sputum, and 41.2% obnubilation. In general, during 2004-2006 the frequency of combined use of metilprednisolon and anticoagulants has increased. Conclusions: Clinical diagnosis remains the most important element for the

  2. Fat embolism among patients with hip and long bone fractures in Albania.

    PubMed

    Hysa, Elida

    2012-01-01

    The aim of this study was to assess the incidence and the effectiveness of treatment of fat embolism in patients with hip and long bone fractures (femur and tibia) in Albania. 229 patients (68% men) with combined hip and long bone fractures (femur and tibia) hospitalized at the Orthopedics-Traumatology Services of the University Center "Mother Teresa" during 2004-2006 were included in the study. Patients were classified into three groups based on astrupogram data: PaO2<60mmHg, 65mmHg75mmHg. Chi square test was used to compare fracture differences between men and women and the effectiveness of combined use of metilprednisolon and anticoagulants vs. anticoagulants alone. Poly traumas combined with femur fracture were more frequent in 2005. These combined poly traumas combined were more frequent among men than women (P<0.001). Remarkably, femur fractures were more frequent among men than women (9:1). Coli femur fractures peaked in the age-group 76-85 years. In general, poly traumas were less frequent in the older age groups, with a peak between 36-55 years, being more frequent among men, but the difference was not statistically significant. Fractures of coli femur and those of tibia were more frequent in 2006, while in 2004 femur fractures were more frequent. In almost all age groups fractures of coli femur were more frequent, followed by fractures of femur and tibia. In general, poly traumas were more frequent among men than women, ranging from 6:1 for fractures of femur to 2:1 for tibia fractures. The incidence of fat embolism ranged from 4.9% to 8.9% for the period 2004-2006. Among fat embolism patients, 100% of them had tachycardia, 88.2% had petechia, 84% tachipnea, 23.5% cyanosis and blood sputum, and 41.2% obnubilation. In general, during 2004-2006 the frequency of combined use of metilprednisolon and anticoagulants has increased. Clinical diagnosis remains the most important element for the detection of fat embolism syndrome. The

  3. Location of civilian ballistic femoral fracture indicates likelihood of arterial injury.

    PubMed

    Gitajn, Leah; Perdue, Paul; Hardcastle, John; O'Toole, Robert V

    2014-10-01

    We evaluated whether the location of a ballistic femoral fracture helps predict the presence of arterial injury. We hypothesized that fractures located in the distal third of the femur are associated with a higher rate of arterial injury. We conducted a retrospective review of electronic medical records at our level I trauma centre and found 133 consecutive patients with femoral fractures from civilian gunshots from 2002 to 2007, 14 of whom sustained arterial injury. Fracture extent was measured with computerized viewing software and recorded with a standard technique, calculating proximal, distal, and central locations of the fracture as a function of overall length of the bone. Analyses were conducted with Student's t, Chi-squared, and Fisher's exact tests. The location of any fracture line in the distal third of the femur was associated with increased risk of arterial injury (P<0.05). The odds ratio for the presence of arterial injury when the proximal fracture line was in the distal third of the femur was 5.63 (95% confidence interval, 1.7-18.6; P<0.05) and when the distal fracture line was in the distal third of the femur was 6.72 (95% confidence interval, 1.78-25.44; P<0.05). A fracture line in the distal third of the femur after ballistic injury is six times more likely to be associated with arterial injury and warrants careful evaluation. Our data show that fracture location can help alert clinicians to possible arterial injury after ballistic femoral fracture. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Accidental Bolt Gun Injury to Femur - A Case Report.

    PubMed

    Kattimani, Ravi Prasad; Shetty, Sanath; Mirza, Humayun

    2016-01-01

    Bolt gun or slaughterer's guns are used in meat industry for "humane killing" of animals. Injuries caused by bolt gun are rare, reported exclusively from central European countries. We report a case of 28 year old male, who accidentally shot himself with a bolt gun to his right thigh. A 28 years old male presented to our Accident and Emergency department after accidental injury to his right thigh with bolt gun. He had an entry wound measuring 2 cm in length and 1 cm in breadth over anterior aspect of lower one third of thigh at lower and sustained Grade II compound fracture of right femur shaft at distal one third. The wound was treated with multiple debridements, negative pressure wound therapy and intravenous antibiotics based on culture and sensitivity. Bolt gun or slaughterer's guns are weapons used in meat industry for slaughtering animals. Wounds inflicted by bolt guns have specific morphological feature, distinctive from wounds made by other kinds of hand firearms. Most of the time wound will be infected at presentation. Lesions caused by these weapons are likely to have a more serious character than is to be expected from the size of the entrance wound. The mainstay of treatment is liberal wound exploration, multiple debridement's and intra venous antibiotics based on culture reports to treat infection and prevent morbidity.

  5. Infected Textiloma, 35 Years after the Operation for Femur Fracture, an extermly rare occurance.

    PubMed

    Sadeghifar, Amir R; Saeed, Ali R

    2013-09-01

    Retained gauze after surgery is an uncommon error and it may be associated with many complications. We are reporting our case to call attention to the fact that retained gauze may become symptomatic even after a very long interval. Herein we report on a patient who developed infection and fistula with discharge from this error 35 years after a surgery for femur fracture and insertion of a IM nail. The diagnosis was easily made because of a marker in the gauze. Removal of the gauze and irrigation and debridement of the wound in two stages led to complete recovery of the patient as was shown in the 1 year follow up. Retained gauze after surgery is a preventable complication and may be asymptomatic for a very long period, but can become a complication post-operatively at any time. Hence, if diagnosed immediately after the surgery or at any other time, the gauze should be removed.

  6. Infected Textiloma, 35 Years after the Operation for Femur Fracture, an extermly rare occurance

    PubMed Central

    Sadeghifar, Amir R; Saeed, Ali R

    2013-01-01

    Retained gauze after surgery is an uncommon error and it may be associated with many complications. We are reporting our case to call attention to the fact that retained gauze may become symptomatic even after a very long interval. Herein we report on a patient who developed infection and fistula with discharge from this error 35 years after a surgery for femur fracture and insertion of a IM nail. The diagnosis was easily made because of a marker in the gauze. Removal of the gauze and irrigation and debridement of the wound in two stages led to complete recovery of the patient as was shown in the 1 year follow up. Retained gauze after surgery is a preventable complication and may be asymptomatic for a very long period, but can become a complication post-operatively at any time. Hence, if diagnosed immediately after the surgery or at any other time, the gauze should be removed. PMID:25207284

  7. The effect of lower limb rehabilitation gymnastics on postoperative rehabilitation in elderly patients with femoral shaft fracture

    PubMed Central

    Yang, Si-Dong; Ning, Sheng-Hua; Zhang, Li-Hong; Zhang, Ying-Ze; Ding, Wen-Yuan; Yang, Da-Long

    2016-01-01

    Abstract The purpose of this study was to explore the effect of lower limb rehabilitation gymnastics on postoperative rehabilitation in elderly patients with femoral shaft fracture after undergoing intramedullary nail fixation surgery. We collected medical records of elderly patients aged ≥ 60 years with femoral shaft fracture between 03/2010 and 03/2015 in Longyao County Hospital. Totally, 160 patients were identified and divided into the intervention group (n = 80) and the control group (n = 80). During the postoperative period, the intervention group received lower limb rehabilitation gymnastics treatment for 3 months, but the control group did not. All patients were routinely asked to return hospital for a check in the 1st postoperative week, as well as the 2nd week, the 1st month, and the 3rd month, after surgery. The clinical rehabilitation effect was evaluated by checking lower limb action ability, detecting the lower limb deep venous thrombosis (DVT), scoring muscle strength of quadriceps and visual analog scale (VAS) score, and performing satisfaction survey. At the 1st week and 2nd week after surgery, the clinical rehabilitation effect in the intervention group was better regarding lower limb action ability, lower limb DVT, muscle strength of quadriceps, VAS score, and patient satisfaction, as compared with the control group. However, there was no significant difference at the 1st month and the 3rd month after surgery when comparing the intervention group to the control group. In the early postoperative stage, lower limb rehabilitation gymnastics can effectively improve the recovery of lower limb function, beneficial to reducing postoperative complications such as lower limb DVT and muscle atrophy, and increasing patient satisfaction rate. PMID:27537579

  8. [Osteoarthritic changes in hip joint in patients with fractures of femoral neck].

    PubMed

    Kravtsov, Vladimir; Saranga, Dan; Kidron, Debora

    2013-06-01

    Fractures of proximal femur are common among elderly people. They are associated with considerable morbidity and mortality. Identification of etiopathogenetic factors associated with fractures might facilitate prevention. Osteoporosis is commonly present in the heads of femurs. The prevalence of osteoarthritic changes in hip joints is controversial. Some authorities report low prevalence and even speculate on the protective effect of osteoarthritis against fractures. The goal of the study was to examine the association between osteoarthritic changes (radiologic and histologic) and fractures of the neck of the femur. The patient population included 41 patients undergoing replacement of femoral head for subcapital fracture; their ages ranged from 61 - 93 years of age. Radiologic criteria for osteoarthritis included: (a)narrowing of joint space (b) subchondral sclerosis (c) deformation of head of femur (d) subchondra cysts and (e] osteophytes. Osteoarthritic changes, usually mild, were present in 22 (54%) patients, regardless of age and gender The frequency of radioLogical changes was similar to the general population. HistoLogic findings included subchondral fibrosis and subchondral cysts. Mild subchondral fibrosis was present in 78% of cases. The findings support lack of association between osteoarthritic changes in hip joint and fracture of proximal femur, without a protective effect.

  9. The Effects of Age, Adiposity, and Physical Activity on the Risk of Seven Site‐Specific Fractures in Postmenopausal Women

    PubMed Central

    Lacombe, Jason; Cairns, Benjamin J; Green, Jane; Reeves, Gillian K; Beral, Valerie

    2016-01-01

    ABSTRACT Risk factors for fracture of the neck of the femur are relatively well established, but those for fracture at other sites are little studied. In this large population study we explore the role of age, body mass index (BMI), and physical activity on the risk of fracture at seven sites in postmenopausal women. As part of the Million Women Study, 1,154,821 postmenopausal UK women with a mean age of 56.0 (SD 4.8) years provided health and lifestyle data at recruitment in 1996 to 2001. All participants were linked to National Health Service (NHS) hospital records for day‐case or overnight admissions with a mean follow‐up of 11 years per woman. Adjusted absolute and relative risks for seven site‐specific incident fractures were calculated using Cox regression models. During follow‐up, 4931 women had a fracture of the humerus; 2926 of the forearm; 15,883 of the wrist; 9887 of the neck of the femur; 1166 of the femur (not neck); 3199 a lower leg fracture; and 10,092 an ankle fracture. Age‐specific incidence rates increased gradually with age for fractures of forearm, lower leg, ankle, and femur (not neck), and steeply with age for fractures of neck of femur, wrist, and humerus. When compared to women with desirable BMI (20.0 to 24.9 kg/m2), higher BMI was associated with a reduced risk of fracture of the neck of femur, forearm, and wrist, but an increased risk of humerus, femur (not neck), lower leg, and ankle fractures (p < 0.001 for all). Strenuous activity was significantly associated with a decreased risk of fracture of the humerus and femur (both neck and remainder of femur) (p < 0.001), but was not significantly associated with lower leg, ankle, wrist, and forearm fractures. Postmenopausal women are at a high lifetime risk of fracture. BMI and physical activity are modifiable risk factors for fracture, but their associations with fracture risk differ substantially across fracture sites. © 2016 The Authors. Journal of Bone and Mineral

  10. Biomechanical Concepts for Fracture Fixation

    PubMed Central

    Bottlang, Michael; Schemitsch, Christine E.; Nauth, Aaron; Routt, Milton; Egol, Kenneth; Cook, Gillian E.; Schemitsch, Emil H.

    2015-01-01

    Application of the correct fixation construct is critical for fracture healing and long-term stability; however, it is a complex issue with numerous significant factors. This review describes a number of common fracture types, and evaluates their currently available fracture fixation constructs. In the setting of complex elbow instability, stable fixation or radial head replacement with an appropriately sized implant in conjunction with ligamentous repair is required to restore stability. For unstable sacral fractures, “standard” iliosacral screw fixation is not sufficient for fractures with vertical or multiplanar instabilities. Periprosthetic femur fractures, in particular Vancouver B1 fractures, have increased stability when using 90/90 fixation versus a single locking plate. Far Cortical Locking combines the concept of dynamization with locked plating in order to achieve superior healing of a distal femur fracture. Finally, there is no ideal construct for syndesmotic fracture stabilization; however, these fractures should be fixed using a device that allows for sufficient motion in the syndesmosis. In general, orthopaedic surgeons should select a fracture fixation construct that restores stability and promotes healing at the fracture site, while reducing the potential for fixation failure. PMID:26584263

  11. Outcome of bone marrow instillation at fracture site in intracapsular fracture of femoral neck treated by head preserving surgery.

    PubMed

    Verma, Nikhil; Singh, M P; Ul-Haq, Rehan; Rajnish, Rajesh K; Anshuman, Rahul

    2017-08-01

    The aim of present study is to evaluate the outcome of bone marrow instillation at the fracture site in fracture of intracapsular neck femur treated by head preserving surgery. This study included 32 patients of age group 18-50 years with closed fracture of intracapsular neck femur. Patients were randomized into two groups as per the plan generated via www.randomization.com. The two groups were Group A (control), in which the fracture of intracapsular neck femur was treated by closed reduction and cannulated cancellous screw fixation, and Group B (intervention), in which additional percutaneous autologous bone marrow aspirate instillation at fracture site was done along with cannulated cancellous screw fixation. Postoperatively the union at fracture site and avascular necrosis of the femoral head were assessed on serial plain radiographs at final follow-up. Functional outcome was evaluated by Harris hip score. The average follow-up was 19.6 months. Twelve patients in each group had union and 4 patients had signs of nonunion. One patient from each group had avascular necrosis of the femoral head. The average Harris hip score at final follow-up in Group A was 80.50 and in Group B was 75.73, which was found to be not significant. There is no significant role of adding on bone marrow aspirate instillation at the fracture site in cases of fresh fracture of intracapsular neck femur treated by head preserving surgery in terms of accelerating the bone healing and reducing the incidence of femoral head necrosis. Copyright © 2017 Daping Hospital and the Research Institute of Surgery of the Third Military Medical University. Production and hosting by Elsevier B.V. All rights reserved.

  12. Safe zones and a technical guide for cerclage wiring of the femur: a computed topographic angiogram (CTA) study.

    PubMed

    Apivatthakakul, Theerachai; Siripipattanamongkol, P; Oh, Chang-Wug; Sananpanich, K; Phornphutkul, C

    2018-01-01

    Cerclage wiring for reduction of complex femoral shaft fractures can create iatrogenic vascular injury. To describe the anatomical relation of blood vessels to the femur and develop a technical guide for safe passage of cerclage wire. CT lower-limb angiographs (CTA) of 80 patients were reviewed and analysed to identify the superficial femoral artery (SFA) and the deep femoral artery (DFA) as well as the relation of those arteries to the femoral cortex. The total length of the femur was measured and divided into eight equal segments (seven levels). At each level, the medial half of the femur was divided into eight sectors labelled A through H and the position of the SFA and DFA was recorded. The shortest distance between the femoral cortex and the SFA and DFA at each level was measured. The data was analysed using STATA version 10.0. The average total femoral length from the tip of greater trochanter to lateral joint line was 402.98 ± 26.16 cm. The average distances from the SFA to the femur (d1) for levels 1 through 7 were 37.20 ± 5.0, 32.09 ± 4.74, 27.13 ± 4.19, 27.71 ± 5.46, 23.71 ± 4.40, 13.63 ± 3.59 and 10.08 ± 3.09 mm, respectively. The average distances between the DFA and the femur (d2) for levels 1 through 3 were 26.70 ± 4.13, 14.76 ± 3.27 and 9.58 ± 3.79 mm, respectively. The position of the SFA is located in sectors B through E at levels 1-3 and in sectors E through H at levels 4-7 and the position of the DFA located in sectors B through F at levels 1-3. Cerclage wiring should be started from the posterior intermuscular septum at the linea aspera. The safe area is the proximal half (midshaft) of the femur where the SFA and DFA lie at a safe distance from the femur. Between the midshaft and the distal 1/4, insertion of the passer must be done meticulously with the tip kept close to posteromedial cortex. Below the distal 1/4, the tip of the passer should be kept close to the posterior cortex to avoid injury to the SFA and

  13. Femoral neck shaft angle width is associated with hip-fracture risk in males but not independently of femoral neck bone density.

    PubMed

    Ripamonti, C; Lisi, L; Avella, M

    2014-05-01

    To investigate the specificity of the neck shaft angle (NSA) to predict hip fracture in males. We consecutively studied 228 males without fracture and 38 with hip fracture. A further 49 males with spine fracture were studied to evaluate the specificity of NSA for hip-fracture prediction. Femoral neck (FN) bone mineral density (FN-BMD), NSA, hip axis length and FN diameter (FND) were measured in each subject by dual X-ray absorptiometry. Between-mean differences in the studied variables were tested by the unpaired t-test. The ability of NSA to predict hip fracture was tested by logistic regression. Compared with controls, FN-BMD (p < 0.01) was significantly lower in both groups of males with fractures, whereas FND (p < 0.01) and NSA (p = 0.05) were higher only in the hip-fracture group. A significant inverse correlation (p < 0.01) was found between NSA and FN-BMD. By age-, height- and weight-corrected logistic regression, none of the tested geometric parameters, separately considered from FN-BMD, entered the best model to predict spine fracture, whereas NSA (p < 0.03) predicted hip fracture together with age (p < 0.001). When forced into the regression, FN-BMD (p < 0.001) became the only fracture predictor to enter the best model to predict both fracture types. NSA is associated with hip-fracture risk in males but is not independent of FN-BMD. The lack of ability of NSA to predict hip fracture in males independent of FN-BMD should depend on its inverse correlation with FN-BMD by capturing, as the strongest fracture predictor, some of the effects of NSA on the hip fracture. Conversely, NSA in females does not correlate with FN-BMD but independently predicts hip fractures.

  14. Femoral neck shaft angle width is associated with hip-fracture risk in males but not independently of femoral neck bone density

    PubMed Central

    Lisi, L; Avella, M

    2014-01-01

    Objective: To investigate the specificity of the neck shaft angle (NSA) to predict hip fracture in males. Methods: We consecutively studied 228 males without fracture and 38 with hip fracture. A further 49 males with spine fracture were studied to evaluate the specificity of NSA for hip-fracture prediction. Femoral neck (FN) bone mineral density (FN-BMD), NSA, hip axis length and FN diameter (FND) were measured in each subject by dual X-ray absorptiometry. Between-mean differences in the studied variables were tested by the unpaired t-test. The ability of NSA to predict hip fracture was tested by logistic regression. Results: Compared with controls, FN-BMD (p < 0.01) was significantly lower in both groups of males with fractures, whereas FND (p < 0.01) and NSA (p = 0.05) were higher only in the hip-fracture group. A significant inverse correlation (p < 0.01) was found between NSA and FN-BMD. By age-, height- and weight-corrected logistic regression, none of the tested geometric parameters, separately considered from FN-BMD, entered the best model to predict spine fracture, whereas NSA (p < 0.03) predicted hip fracture together with age (p < 0.001). When forced into the regression, FN-BMD (p < 0.001) became the only fracture predictor to enter the best model to predict both fracture types. Conclusion: NSA is associated with hip-fracture risk in males but is not independent of FN-BMD. Advances in knowledge: The lack of ability of NSA to predict hip fracture in males independent of FN-BMD should depend on its inverse correlation with FN-BMD by capturing, as the strongest fracture predictor, some of the effects of NSA on the hip fracture. Conversely, NSA in females does not correlate with FN-BMD but independently predicts hip fractures. PMID:24678889

  15. Development and testing of texture discriminators for the analysis of trabecular bone in proximal femur radiographs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huber, M. B.; Carballido-Gamio, J.; Fritscher, K.

    2009-11-15

    Purpose: Texture analysis of femur radiographs may serve as a potential low cost technique to predict osteoporotic fracture risk and has received considerable attention in the past years. A further application of this technique may be the measurement of the quality of specific bone compartments to provide useful information for treatment of bone fractures. Two challenges of texture analysis are the selection of the best suitable texture measure and reproducible placement of regions of interest (ROIs). The goal of this in vitro study was to automatically place ROIs in radiographs of proximal femur specimens and to calculate correlations between variousmore » different texture analysis methods and the femurs' anchorage strength. Methods: Radiographs were obtained from 14 femoral specimens and bone mineral density (BMD) was measured in the femoral neck. Biomechanical testing was performed to assess the anchorage strength in terms of failure load, breakaway torque, and number of cycles. Images were segmented using a framework that is based on the usage of level sets and statistical in-shape models. Five ROIs were automatically placed in the head, upper and lower neck, trochanteric, and shaft compartment in an atlas subject. All other subjects were registered rigidly, affinely, and nonlinearly, and the resulting transformation was used to map the five ROIs onto the individual femora. Results: In each ROI, texture features were extracted using gray level co-occurence matrices (GLCM), third-order GLCM, morphological gradients (MGs), Minkowski dimensions (MDs), Minkowski functionals (MFs), Gaussian Markov random fields, and scaling index method (SIM). Coefficients of determination for each texture feature with parameters of anchorage strength were computed. In a stepwise multiregression analysis, the most predictive parameters were identified in different models. Texture features were highly correlated with anchorage strength estimated by the failure load of up to R

  16. [The effect of verticalization of the resulting force (R) of weight bearing in the hip joint on morphologic characteristics of the medullary canal in the femoral shaft in patients with coxarthrosis].

    PubMed

    Jovanović, S

    1992-01-01

    An influence of verticalization of the resulting force of weight-bearing on the hip joint "R" on the morphological characteristics of the medullar canal on the proximal edge of the shaft of femur was researched. Progressive degenerative changes of the hip joint with a consequent sideways limping or changes of the collodiaphysial angle (ccd angle) were the cause of the verticalization of the resulting force "R". The analysis of patients treated and operated on The Orthopaedic Department of the General Hospital Osijek and The Orthopaedic Clinic of The Medical Faculty of The University of Zagreb. The research, undoubtedly, proved that the patients with coxarthrosis and side-ways in the hip or with changed collodiaphysial angle experienced verticalization of the resulting force of weigh-bearing of the hip joint and the proximal edge of femur which caused morphological changes of the medular canal of the shaft of femur.

  17. RECONSIDERATIONS REGARDING TIME OF FRACTURE HEALING IN PYCNODYSOSTOSIS

    PubMed Central

    Rabelo, Flávio Dorcilo; do Prado, Carlos Henrique Ribeiro; Rabelo, Flávio Leão; Martins, Letícia

    2015-01-01

    Objective: To discuss what has been described so far in the literature regarding the time taken for fracture consolidation in pycnodysostosis. Materials and Methods: Thirteen new cases were studied, as available from the medical records and radiographic examinations, thus encompassing a total of 44 fractures in patients evaluated between November 1970 and August 2004 at the Orthopedics Hospital, Goiânia. Field research, simultaneous clinical monitoring for new fractures in two patients and retrospective evaluation of medical records were undertaken. The purpose was to determine the total number of fractures in each patient and to determine which of these were viable for this study. The patient group was composed of three women and two men of mean age 51.4 years. The tibia was the bone most affected, followed by the femur. Fractures for which the follow-up was done at another clinic were excluded. Results: Out of the 12 fractures that were considered fully suitable for the study, nine occurred in femurs (six in the left femur and three in the right femur); one in the right tibia; one in the right clavicle; and one in the left ulna. Among these 12 fractures, eight developed pseudarthrosis after an average of 29.25 months; three consolidated well after an average of 5.83 months; and one evolved with delayed consolidation in just 2 months. Conclusion: In combination with genetic and micromorphological evaluations, further studies are awaited for reconfirmation of the diagnosis of such a rare clinical entity. PMID:27026972

  18. Impact energy absorption by specimens from the upper end of the human femur.

    PubMed

    Panagiotopoulos, E; Kostopoulos, V; Tsantzalis, S; Fortis, A P; Doulalas, A

    2005-05-01

    A cadaveric biomechanical study was performed to investigate the fracture energy absorbed by strips of bone from the proximal femur in relation to age and gender, under impact loading conditions. Four groups (young male, young female, old male, old female) of four cadaveric proximal femurs were used in each case. Four bone strips were taken from the neck and four from the subtrochanteric area and these were tested under dynamic-impact conditions using the Charpy impact test. The fracture energy was calculated as the energy needed to achieve fracture per unit area, and expressed in J/m2. Bone specimens from young males are significantly tougher under impact conditions to those of females (p = 0.001), whereas between the old male and female groups, fracture energy does not significantly differ (p = 0.165). There was also significant difference (p < 0.0005) between the young and the old groups in both genders. The fracture energy absorption of the subtrochanteric area compared to that of the femoral neck for the same group of age and gender is in general slightly higher for all groups. In conclusion, gender in the young age group played a significant role in bone resistance in breaking whereas in the older age group it played a less important role.

  19. Radiation-induced alterations of fracture healing biomechanics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pelker, R.R.; Friedlaender, G.E.; Panjabi, M.M.

    1984-01-01

    The effects of irradiation on the normal temporal progression of the physical properties of healing fractures were studied in a rat model. Fractures were surgically produced in the femur, stabilized with an intramedullary pin, and irradiated. One group of rats was exposed to 2,500 rads in divided doses over 2 weeks, beginning 3 days after fracture, and compared to a control group with fractures which were not irradiated. Animals were sacrificed at periodic intervals and the bones were tested to failure in torsion. The torque, stiffness, and energy increased and the angle decreased for the nonirradiated specimens in the expectedmore » fashion. This progression was deleteriously altered in the irradiated femurs.« less

  20. Pediatric distal femur fixation by proximal humeral plate.

    PubMed

    Abdelgawad, Amr Atef; Kanlic, Enes M

    2013-12-01

    Distal femoral metaphyseal fractures are common injuries in children. Multiple treatment options have been described for this type of injury. For older children with distal metaphyseal fracture, there is still no optimal method of fixation. We propose that the commonly used proximal humeral plate can provide good method of fixation for this fracture in adolescents. Two children (12 and 14 years old) with distal metaphyseal femoral fracture were treated with proximal humeral plate. We describe the surgical technique and postoperative management. The two children healed with good alignment and full range of motion of the knee. No external immobilization (other than knee immobilizer for the first 2 weeks) was used. We concluded that proximal humeral plate can provide adequate fixation for teenagers with distal femoral metaphyseal fracture. It is readily available; provide multiple options for screw fixation in the distal part of the fracture and fits easily on the distal part of the femur proximal to the physis. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  1. Long-bone fractures in persons with spinal cord injury.

    PubMed

    Frotzler, A; Cheikh-Sarraf, B; Pourtehrani, M; Krebs, J; Lippuner, K

    2015-09-01

    Retrospective data analysis. To document fracture characteristics, management and related complications in individuals with traumatic spinal cord injury (SCI). Rehabilitation centre for SCI individuals. Patients' records were reviewed. Patients with traumatic SCI and extremity fractures that had occurred after SCI were included. Patient characteristics, fractured bone, fracture localisation, severity and management (operative/conservative), and fracture-related complications were extracted. A total of 156 long-bone fractures in 107 SCI patients (34 women and 73 men) were identified. The majority of patients were paraplegics (77.6%) and classified as American Spinal Injury Association Impairment Scale A (86.0%). Only the lower extremities were affected, whereby the femur (60.9% of all fractures) was fractured more frequently than the lower leg (39.1%). A total of 70 patients (65.4%) had one fracture, whereas 37 patients (34.6%) had two or more fractures. Simple or extraarticular fractures were most common (75.0%). Overall, 130 (83.3%) fractures were managed operatively. Approximately half of the femur fractures (48.2%) were treated with locking compression plates. In the lower leg, fractures were mainly managed with external fixation (48.8%). Conservative fracture management was applied in 16.7% of the cases and consisted of braces or a well-padded soft cast. Fracture-associated complications were present in 13.5% of the cases but did not differ significantly between operative (13.1%) and conservative (15.4%) fracture management. SCI was associated with simple or extraarticular fractures of the distal femur and the lower leg. Fractures were mainly managed operatively with a low complication rate.

  2. Proximal femoral fractures: Principles of management and review of literature.

    PubMed

    Mittal, Ravi; Banerjee, Sumit

    2012-06-01

    The purpose of this study was to review the principles involved in the management of proximal femoral fractures as reported in the literature. A medical literature search in the MEDLINE (PubMed) and Cochrane database was undertaken to review strategies and principles in proximal femoral fracture treatment. Randomized control trials and meta analysis were given preference while case reports/small series were rejected. Early anatomical reduction and surgical fixation remains the best option to reduce the risk of complications like non-union and avascular necrosis in treating fracture neck femurs. Cancellous screws continue to be the preferred treatment for fixation of neck femur fractures in younger population until the benefit of using sliding hip screws is validated by large multicentric studies. In the geriatric age group, early prosthetic replacement brings down the mortality and morbidity associated with neck femur fractures. Sliding hip screw (DHS) is the best available option for stable inter trochanteric fractures. The use of intramedullary nails e.g. PFN is beneficial in treating inter trochanteric fractures with comminution and loss of lateral buttress. Intramedullary implants have been proven to have increased success rates in subtrochanteric fractures and should be preferred over extramedullary plate fixation systems.

  3. Distinct frequency dependent effects of whole-body vibration on non-fractured bone and fracture healing in mice.

    PubMed

    Wehrle, Esther; Wehner, Tim; Heilmann, Aline; Bindl, Ronny; Claes, Lutz; Jakob, Franz; Amling, Michael; Ignatius, Anita

    2014-08-01

    Low-magnitude high-frequency vibration (LMHFV) provokes anabolic effects in non-fractured bone; however, in fracture healing, inconsistent results were reported and optimum vibration conditions remain unidentified. Here, we investigated frequency dependent effects of LMHFV on fracture healing. Twelve-week-old, female C57BL/6 mice received a femur osteotomy stabilized using an external fixator. The mice received whole-body vibrations (20 min/day) with 0.3g peak-to-peak acceleration and a frequency of either 35 or 45 Hz. After 10 and 21 days, the osteotomized femurs and intact bones (contra-lateral femurs, lumbar spine) were evaluated using bending-testing, µ-computed tomography, and histomorphometry. In non-fractured trabecular bone, vibration with 35 Hz significantly increased the relative amount of bone (+28%) and the trabecular number (+29%), whereas cortical bone was not influenced. LMHFV with 45 Hz failed to provoke anabolic effects in trabecular or cortical bone. Fracture healing was not significantly influenced by whole-body vibration with 35 Hz, whereas 45 Hz significantly reduced bone formation (-64%) and flexural rigidity (-34%) of the callus. Although the exact mechanisms remain open, our results suggest that small vibration setting changes could considerably influence LMHFV effects on bone formation in remodeling and repair, and even disrupt fracture healing, implicating caution when treating patients with impaired fracture healing. © 2014 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  4. Morphometric analysis of the femur in cerebral palsy: 3-dimensional CT study.

    PubMed

    Gose, Shinichi; Sakai, Takashi; Shibata, Toru; Murase, Tsuyoshi; Yoshikawa, Hideki; Sugamoto, Kazuomi

    2010-09-01

    The cause of hip disorder in cerebral palsy (CP) has been thought to involve muscle imbalance, flexion, and adduction contracture of the hip joint, acetabular dysplasia, and femoral growth abnormalities. The aim of this study was to quantitatively evaluate the 3-dimensional femoral geometry and subluxation/dislocation of the hip in spastic CP using 3D-CT reconstructed images of the pelvis and the femur, focusing on the femoral growth abnormalities in CP. Between June 2006 and September 2009, 186 hips in 93 bilateral spastic CP patients, including spastic diplegia (SD) in 73 patients and spastic quadriplegia (SQ) in 20 patients, who had not received any surgical treatment, were investigated using 3D-CT at our hospital. There were 59 boys and 34 girls with an average age of 5.3 years (range: 2.6 to 6.8 y). As an index for the femoral geometry, the neck-shaft angle, the femoral anteversion, and the femoral offset were 3-dimensionally measured. The center of the acetabulum and the femoral head were determined to calculate the CT migration percentage as the distance between these centers divided by the femoral head diameter. To elucidate the factors related to hip subluxation/dislocation, the relationships between the neck-shaft angle, the femoral anteversion, the femoral offset, and the CT migration percentage were investigated. The mean neck-shaft angle was 150.4+/-9.4 degrees (range: 129.4 to 173.2 degrees). The mean femoral anteversion was 44.4+/-13.6 degrees (range: 5.8 to 84.0 degrees). The mean CT migration percentage was 22.4+/-22.7% (range: 3 to 129%). There was positive correlation between the CT migration percentage and the neck-shaft angle (r=0.49). Hips with large CT migration percentage tended to show coxa valga. There was an inverse correlation between the neck-shaft angle and the femoral offset (r=-0.90), but no correlation between the CT migration percentage and the femoral anteversion (r=0.26), between the femoral offset and the femoral anteversion (r

  5. Proximal femoral fractures.

    PubMed

    Webb, Lawrence X

    2002-01-01

    Fractures of the proximal femur include fractures of the head, neck, intertrochanteric, and subtrochanteric regions. Head fractures commonly accompany dislocations. Neck fractures and intertrochanteric fractures occur with greatest frequency in elderly patients with a low bone mineral density and are produced by low-energy mechanisms. Subtrochanteric fractures occur in a predominantly strong cortical osseous region which is exposed to large compressive stresses. Implants used to address these fractures must be able to accommodate significant loads while the fractures consolidate. Complications secondary to these injuries produce significant morbidity and include infection, nonunion, malunion, decubitus ulcers, fat emboli, deep venous thrombosis, pulmonary embolus, pneumonia, myocardial infarction, stroke, and death.

  6. Angle of torsion of the femur and its correlates.

    PubMed

    Prasad, R; Vettivel, S; Isaac, B; Jeyaseelan, L; Chandi, G

    1996-01-01

    Unpaired femora (171), devoid of gross pathology and grouped by gender (94 male and 77 female) and side (88 left and 83 right), were used to measure the angle of femoral torsion and the maximum femur length and to score the degree of prominency of the superior cervical tubercle, intertrochanteric line, quadrate tubercle, linea aspera, and adductor tubercle. The angle of torsion ranged from -9 to +35 degrees with a mean of +12.3 degrees. The means were not significantly different either by gender or side. The angle correlated negatively with superior cervical tubercle, intertrochanteric line, and adductor tubercle (P < 0.001), positively with quadrate tubercle (P < 0.001) but not with linea aspera, neck-shaft angle, or length of femur. Bony prominences were significantly more apparent in males. There was no significant association between prominency and side. The torsion seems to be brought about by muscular activity and capsular and ligamentous strain at the hip. This study suggests to clinicians the possibility of correction of torsion defects in certain hip diseases of growing children by suitable alteration in posture of the lower extremity.

  7. Prediction of biomechanical parameters of the proximal femur using statistical appearance models and support vector regression.

    PubMed

    Fritscher, Karl; Schuler, Benedikt; Link, Thomas; Eckstein, Felix; Suhm, Norbert; Hänni, Markus; Hengg, Clemens; Schubert, Rainer

    2008-01-01

    Fractures of the proximal femur are one of the principal causes of mortality among elderly persons. Traditional methods for the determination of femoral fracture risk use methods for measuring bone mineral density. However, BMD alone is not sufficient to predict bone failure load for an individual patient and additional parameters have to be determined for this purpose. In this work an approach that uses statistical models of appearance to identify relevant regions and parameters for the prediction of biomechanical properties of the proximal femur will be presented. By using Support Vector Regression the proposed model based approach is capable of predicting two different biomechanical parameters accurately and fully automatically in two different testing scenarios.

  8. Pre-operative digital templating in cemented hip hemiarthroplasty for neck of femur fractures.

    PubMed

    Kwok, Iris H Y; Pallett, Scott J C; Massa, Edward; Cundall-Curry, Duncan; Loeffler, Mark D

    2016-03-01

    Pre-operative digital templating allows the surgeon to foresee any anatomical anomalies which may lead to intra-operative problems, and anticipate appropriate instruments and implants required during surgery. Although its role is well-established in successful elective total hip arthroplasty, little work has been done on its use in hip hemiarthroplasty in neck of femur fractures. We describe our initial experience of digital templating in 40 consecutive patients who have undergone cemented hip hemiarthroplasty, assessing templating accuracy between templated implant sizes to actual implant sizes. 81% of implanted heads were templated to within two head sizes, and 89% of implanted stems were templated to within two sizes. Although there was a moderately strong correlation of 0.52 between templated and actual head sizes, this correlation was not demonstrated in femoral stem sizes. Mean leg length discrepancy was -2.5mm (S.D. 8.5), and the mean difference in femoral offset between the operated and non-operated hip was -1mm (S.D. 4.4). Digital templating is a useful adjunct to the surgeon in pre-operative planning of hip hemiarthroplasty in the restoration of leg length and femoral offset. However, its accuracy is inferior to that of elective total hip arthroplasty. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. The effects of once-weekly teriparatide on hip geometry assessed by hip structural analysis in postmenopausal osteoporotic women with high fracture risk.

    PubMed

    Sone, Teruki; Ito, Masako; Fukunaga, Masao; Tomomitsu, Tatsushi; Sugimoto, Toshitsugu; Shiraki, Masataka; Yoshimura, Takeshi; Nakamura, Toshitaka

    2014-07-01

    Weekly administration of teriparatide has been shown to reduce the risk of vertebral and non-vertebral fractures in patients with osteoporosis at higher fracture risk in Japan. However, its efficacy for hip fracture has not been established. To gain insight into the effect of weekly teriparatide on the hip, hip structural analysis (HSA) based on dual-energy X-ray absorptiometry (DXA) was performed using the data of 209 postmenopausal osteoporotic women who had participated in the original randomized, multicenter, double-blind, placebo-controlled trial assessing the effects of once-weekly 56.5 μg teriparatide for 72 weeks. The DXA scans, obtained at baseline, 48 weeks and 72 weeks, were analyzed to extract bone mineral density (BMD) and cross-sectional geometrical indices at the narrowest point on the neck (NN), the intertrochanteric region (IT), and the proximal shaft. Compared with placebo after 72 weeks, the teriparatide group showed significantly higher BMD, average cortical thickness, bone cross-sectional area, and section modulus, and lower buckling ratio at both the NN and IT regions. No significant expansion of periosteal diameter was observed at these regions. There were no significant differences in BMD and HSA indices at the shaft region. The results indicate that overall structural strength in the proximal femur increased compared to placebo, suggesting that once-weekly teriparatide effectively reverses changes in hip geometry and strength with aging. Copyright © 2014. Published by Elsevier Inc.

  10. Correlation between Parameters of Calcaneal Quantitative Ultrasound and Hip Structural Analysis in Osteoporotic Fracture Patients

    PubMed Central

    Zheng, Hailiang; Li, Ming; Yin, Pengbin; Peng, Ye; Gao, Yuan; Zhang, Lihai; Tang, Peifu

    2015-01-01

    Background Calcaneal quantitative ultrasound (QUS), which is used in the evaluation of osteoporosis, is believed to be intimately associated with the characteristics of the proximal femur. However, the specific associations of calcaneal QUS with characteristics of the hip sub-regions remain unclear. Design A cross-sectional assessment of 53 osteoporotic patients was performed for the skeletal status of the heel and hip. Methods We prospectively enrolled 53 female osteoporotic patients with femoral fractures. Calcaneal QUS, dual energy X-ray absorptiometry (DXA), and hip structural analysis (HSA) were performed for each patient. Femoral heads were obtained during the surgery, and principal compressive trabeculae (PCT) were extracted by a three-dimensional printing technique-assisted method. Pearson’s correlation between QUS measurement with DXA, HSA-derived parameters and Young’s modulus were calculated in order to evaluate the specific association of QUS with the parameters for the hip sub-regions, including the femoral neck, trochanteric and Ward’s areas, and the femoral shaft, respectively. Results Significant correlations were found between estimated BMD (Est.BMD) and BMD of different sub-regions of proximal femur. However, the correlation coefficient of trochanteric area (r = 0.356, p = 0.009) was higher than that of the neck area (r = 0.297, p = 0.031) and total proximal femur (r = 0.291, p = 0.034). Furthermore, the quantitative ultrasound index (QUI) was significantly correlated with the HSA-derived parameters of the trochanteric area (r value: 0.315–0.356, all p<0.05) as well as with the Young’s modulus of PCT from the femoral head (r = 0.589, p<0.001). Conclusion The calcaneal bone had an intimate association with the trochanteric cancellous bone. To a certain extent, the parameters of the calcaneal QUS can reflect the characteristics of the trochanteric area of the proximal hip, although not specifically reflective of those of the femoral neck

  11. Proximal femoral fractures: Principles of management and review of literature

    PubMed Central

    Mittal, Ravi; Banerjee, Sumit

    2012-01-01

    Purpose The purpose of this study was to review the principles involved in the management of proximal femoral fractures as reported in the literature. Methods: A medical literature search in the MEDLINE (PubMed) and Cochrane database was undertaken to review strategies and principles in proximal femoral fracture treatment. Randomized control trials and meta analysis were given preference while case reports/small series were rejected. Results and conclusions: Early anatomical reduction and surgical fixation remains the best option to reduce the risk of complications like non-union and avascular necrosis in treating fracture neck femurs. Cancellous screws continue to be the preferred treatment for fixation of neck femur fractures in younger population until the benefit of using sliding hip screws is validated by large multicentric studies. In the geriatric age group, early prosthetic replacement brings down the mortality and morbidity associated with neck femur fractures. Sliding hip screw (DHS) is the best available option for stable inter trochanteric fractures. The use of intramedullary nails e.g. PFN is beneficial in treating inter trochanteric fractures with comminution and loss of lateral buttress. Intramedullary implants have been proven to have increased success rates in subtrochanteric fractures and should be preferred over extramedullary plate fixation systems. PMID:25983451

  12. Preliminary analysis of force-torque measurements for robot-assisted fracture surgery.

    PubMed

    Georgilas, Ioannis; Dagnino, Giulio; Tarassoli, Payam; Atkins, Roger; Dogramadzi, Sanja

    2015-08-01

    Our group at Bristol Robotics Laboratory has been working on a new robotic system for fracture surgery that has been previously reported [1]. The robotic system is being developed for distal femur fractures and features a robot that manipulates the small fracture fragments through small percutaneous incisions and a robot that re-aligns the long bones. The robots controller design relies on accurate and bounded force and position parameters for which we require real surgical data. This paper reports preliminary findings of forces and torques applied during bone and soft tissue manipulation in typical orthopaedic surgery procedures. Using customised orthopaedic surgical tools we have collected data from a range of orthopaedic surgical procedures at Bristol Royal Infirmary, UK. Maximum forces and torques encountered during fracture manipulation which involved proximal femur and soft tissue distraction around it and reduction of neck of femur fractures have been recorded and further analysed in conjunction with accompanying image recordings. Using this data we are establishing a set of technical requirements for creating safe and dynamically stable minimally invasive robot-assisted fracture surgery (RAFS) systems.

  13. Prediction of Hip Failure Load: In Vitro Study of 80 Femurs Using Three Imaging Methods and Finite Element Models-The European Fracture Study (EFFECT).

    PubMed

    Pottecher, Pierre; Engelke, Klaus; Duchemin, Laure; Museyko, Oleg; Moser, Thomas; Mitton, David; Vicaut, Eric; Adams, Judith; Skalli, Wafa; Laredo, Jean Denis; Bousson, Valérie

    2016-09-01

    Purpose To evaluate the performance of three imaging methods (radiography, dual-energy x-ray absorptiometry [DXA], and quantitative computed tomography [CT]) and that of a numerical analysis with finite element modeling (FEM) in the prediction of failure load of the proximal femur and to identify the best densitometric or geometric predictors of hip failure load. Materials and Methods Institutional review board approval was obtained. A total of 40 pairs of excised cadaver femurs (mean patient age at time of death, 82 years ± 12 [standard deviation]) were examined with (a) radiography to measure geometric parameters (lengths, angles, and cortical thicknesses), (b) DXA (reference standard) to determine areal bone mineral densities (BMDs), and (c) quantitative CT with dedicated three-dimensional analysis software to determine volumetric BMDs and geometric parameters (neck axis length, cortical thicknesses, volumes, and moments of inertia), and (d) quantitative CT-based FEM to calculate a numerical value of failure load. The 80 femurs were fractured via mechanical testing, with random assignment of one femur from each pair to the single-limb stance configuration (hereafter, stance configuration) and assignment of the paired femur to the sideways fall configuration (hereafter, side configuration). Descriptive statistics, univariate correlations, and stepwise regression models were obtained for each imaging method and for FEM to enable us to predict failure load in both configurations. Results Statistics reported are for stance and side configurations, respectively. For radiography, the strongest correlation with mechanical failure load was obtained by using a geometric parameter combined with a cortical thickness (r(2) = 0.66, P < .001; r(2) = 0.65, P < .001). For DXA, the strongest correlation with mechanical failure load was obtained by using total BMD (r(2) = 0.73, P < .001) and trochanteric BMD (r(2) = 0.80, P < .001). For quantitative CT, in both configurations

  14. A comparative study of the therapeutic effect between long and short intramedullary nails in the treatment of intertrochanteric femur fractures in the elderly.

    PubMed

    Guo, Xue-Feng; Zhang, Ke-Ming; Fu, Hong-Bo; Cao, Wen; Dong, Qiang

    2015-01-01

    To compare the clinical effects of long vs. short intramedullary nails in the treatment of intertrochanteric fractures in old patients more than 65 years old. A retrospective analysis of 178 cases of intertrochanteric fractures of the femur (AO type A1 and A2) in the elderly was conducted from January 2008 to December 2013. There were 85 males (47.8%) and 93 females (52.2%) with the age of 65e89 (70.2±10.8) years. The patients were treated by closed reduction and long or short intramedullary nail (Gamma 3) fixation. The length of short nail was 180 mm and that for long nail was 320e360 mm. The general data of patients, operation time, intraoperative blood loss, length of hospital stay, preoperative hemoglobin level, blood transfusion rate, postoperative periprosthetic fractures, infections, complications, etc were carefully recorded. There were 76 cases (42.7%) in the long intramedullary nail group and 102 cases (57.3%) in the short nail group. All the cases were followed up for 12e48 (21.3±6.8) months, during which there were 21 deaths (11.8%), mean (13.8±6.9) months after operation. The intraoperative blood loss was (90.7±50.6) ml in short nail group, greatly less than that in long nail group (127.8±85.9) ml (p=0.004). The short nail group also had a significantly shorter operation time (43.5 min±12.3 min vs. 58.5 min±20.3 min, p=0.002) and lower rate of postoperative transfusion (42.3% vs. 56.7%, p=0.041). But the length of hospital stay showed no big differences. After operation, in each group there was 1 case of periprosthetic fracture with a total incidence of 1.1%, 1.3% in long nail group and 0.9% in short nail group. At the end of the follow-up, all patients achieved bony union. The average healing time of the long nail group was (6.5±3.1) months, and the short nail group was (6.8±3.7) months, revealing no significant differences (p=0.09). Postoperative complications showed no great differences either. Both the intramedullary long and short nail

  15. Three-dimensional measurement of femur based on structured light scanning

    NASA Astrophysics Data System (ADS)

    Li, Jie; Ouyang, Jianfei; Qu, Xinghua

    2009-12-01

    Osteometry is fundamental to study the human skeleton. It has been widely used in palaeoanthropology, bionics, and criminal investigation for more than 200 years. The traditional osteometry is a simple 1-dimensional measurement that can only get 1D size of the bones in manual step-by-step way, even though there are more than 400 parameters to be measured. For today's research and application it is significant and necessary to develop an advanced 3-dimensional osteometry technique. In this paper a new 3D osteometry is presented, which focuses on measurement of the femur, the largest tubular bone in human body. 3D measurement based on the structured light scanning is developed to create fast and precise measurement of the entire body of the femur. The cloud data and geometry model of the sample femur is established in mathematic, accurate and fast way. More than 30 parameters are measured and compared with each other. The experiment shows that the proposed method can meet traditional osteometry and obtain all 1D geometric parameters of the bone at the same time by the mathematics model, such as trochanter-lateral condyle length, superior breadth of shaft, and collo-diaphyseal angle, etc. In the best way, many important geometric parameters that are very difficult to measure by existing osteometry, such as volume, surface area, and curvature of the bone, can be obtained very easily. The overall measuring error is less than 0.1mm.

  16. Three-dimensional measurement of femur based on structured light scanning

    NASA Astrophysics Data System (ADS)

    Li, Jie; Ouyang, Jianfei; Qu, Xinghua

    2010-03-01

    Osteometry is fundamental to study the human skeleton. It has been widely used in palaeoanthropology, bionics, and criminal investigation for more than 200 years. The traditional osteometry is a simple 1-dimensional measurement that can only get 1D size of the bones in manual step-by-step way, even though there are more than 400 parameters to be measured. For today's research and application it is significant and necessary to develop an advanced 3-dimensional osteometry technique. In this paper a new 3D osteometry is presented, which focuses on measurement of the femur, the largest tubular bone in human body. 3D measurement based on the structured light scanning is developed to create fast and precise measurement of the entire body of the femur. The cloud data and geometry model of the sample femur is established in mathematic, accurate and fast way. More than 30 parameters are measured and compared with each other. The experiment shows that the proposed method can meet traditional osteometry and obtain all 1D geometric parameters of the bone at the same time by the mathematics model, such as trochanter-lateral condyle length, superior breadth of shaft, and collo-diaphyseal angle, etc. In the best way, many important geometric parameters that are very difficult to measure by existing osteometry, such as volume, surface area, and curvature of the bone, can be obtained very easily. The overall measuring error is less than 0.1mm.

  17. Femur Osteomyelitis Due to a Mixed Fungal Infection in a Previously Healthy Man

    PubMed Central

    Cimerman, M.; Gunde-Cimerman, N.; Zalar, P.; Perkovic, T.

    1999-01-01

    We describe a previously healthy, 22-year-old man who, after a closed fracture of the femur and subsequent operation, developed chronic osteomyelitis. Within a few days, infected bone fragments, bone, and wound drainage repeatedly yielded three different filamentous fungi: Aspergillus fumigatus, Aspergillus flavus, and Chalara ellisii. Histologic examination of the bone revealed septate hyphae. After sequential necrotomies of the femur and irrigation-suction drainage with added antimycotic therapy, the infection ceased and the fracture healed. This case is unique in that it is the only known instance in which a long bone was affected in an immunocompetent individual, with no evidence of any systemic infection, by a mixed population of two different Aspergillus spp. and the rare filamentous fungus C. ellisii. Environmental factors that could potentiate the infection include blood and edema fluid resulting from the surgical procedure and the presence of the osteosynthetic plate. PMID:10203517

  18. 118. #3 SHAFT ALLEY (PROPELLER SHAFT) FORWARD LOOKING AFT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    118. #3 SHAFT ALLEY (PROPELLER SHAFT) - FORWARD LOOKING AFT ON PORT SIDE SHOWING THE SHAFT, SHAFT PACKING GLAND, SHAFT SEAL COOLING WATER LINE AND FIVE INCH FIRE MAIN PIPING. - U.S.S. HORNET, Puget Sound Naval Shipyard, Sinclair Inlet, Bremerton, Kitsap County, WA

  19. The biomechanics of plate fixation of periprosthetic femoral fractures near the tip of a total hip implant: cables, screws, or both?

    PubMed

    Shah, S; Kim, S Y R; Dubov, A; Schemitsch, E H; Bougherara, H; Zdero, R

    2011-09-01

    Femoral shaft fractures after total hip arthroplasty (THA) remain a serious problem, since there is no optimal surgical repair method. Virtually all studies that examined surgical repair methods have done so clinically or experimentally. The present study assessed injury patterns computationally by developing three-dimensional (3D) finite element (FE) models that were validated experimentally. The investigation evaluated three different constructs for the fixation of Vancouver B1 periprosthetic femoral shaft fractures following THA. Experimentally, three bone plate repair methods were applied to a synthetic femur with a 5 mm fracture gap near the tip of a total hip implant. Repair methods were identical distal to the fracture gap, but used cables only (construct A), screws only (construct B), or cables plus screws (construct C) proximal to the fracture gap. Specimens were oriented in 15 degrees adduction to simulate the single-legged stance phase of walking, subjected to 1000 N of axial force, and instrumented with strain gauges. Computationally, a linearly elastic and isotropic 3D FE model was developed to mimic experiments. Results showed excellent agreement between experimental and FE strains, yielding a Pearson linearity coefficient, R2, of 0.92 and a slope for the line of best data fit of 1.06. FE-computed axial stiffnesses were 768 N/mm (construct A), 1023 N/mm (construct B), and 1102 N/mm (construct C). FE surfaces stress maps for cortical bone showed Von Mises stresses, excluding peaks, of 0-8 MPa (construct A), 0-15 MPa (construct B), and 0-20 MPa (construct C). Cables absorbed the majority of load, followed by the plates and then the screws. Construct A yielded peak stress at one of the empty holes in the plate. Constructs B and C had similar bone stress patterns, and can achieve optimal fixation.

  20. EPIDEMIOLOGICAL STUDY OF CHILDREN DIAPHYSEAL FEMORAL FRACTURES

    PubMed Central

    Hoffmann, Cassiano Ricardo; Traldi, Eduardo Franceschini; Posser, Alexandre

    2015-01-01

    Objective: To evaluate the personal, fracture, treatment and complication characteristics among patients with pediatric femoral shaft fractures attended at the pediatric orthopedic service of the Joana de Gusmão Children's Hospital. Methods: This was a retrospective cross-sectional study on a population consisting of patients with femoral shaft fractures, aged between birth and 14 years and 11 months, who were divided into four age groups. Information was obtained from medical records and was transferred to a survey questionnaire to present personal, fracture, treatment and complication variables. Results: The study population consisted of 96 patients. Their mean age was 6.8 years. The cases were predominantly among males, comprising closed fractures on the right side, in the middle third with a single line. Regarding fracture etiology, traffic accidents predominated overall in the sample. Most of the patients (74 to 77.1%) presented femoral fractures as their only injury. Conservative treatment predominated in the group younger than six years of age, and surgical treatment in the group aged 6 to 14 years and 11 months. The complications observed until bone union were: discrepancy, infection and movement limitation. The mean time taken for consolidation was 9.6 ± 2.4 weeks, varying with age. Conclusion: The features of these fractures were similar to those described in the literature and the treatment used showed good results. The Joana de Gusmão Children's Hospital has used the treatment proposed in the literature for pediatric femoral shaft fractures. PMID:27042619

  1. Osteosynthesis using plates and screws after removing a limited area of the periosteum in order to reduce misclassified during radiological assessment metacarpal shaft fractures

    PubMed Central

    Neagu, TP; Popescu, SA; Cobilinschi, C; Tincu, R; Tiglis, M; Lascar, I

    2016-01-01

    Hand fractures are one of the most common causes for presenting to the emergency room. Metacarpal fractures count about 18 to 44% of all hand fractures, and are most often standalone closed injuries, without misplacement, not needing operative treatment. We present a case in which osteosynthesis with plates and screws was used to reduce two metacarpal fractures in order to allow an early motion recovery, despite the fact that a small portion of the periosteum needed to be removed. The type of fractures were misclassified according to the radiological findings, therefore the correct diagnosis was established during surgery. The results according to the radiological aspects and to the DASH score were excellent with 95% function recovery at twelve months. In this case, the use of osteosynthesis with plates and screws led to a good fracture healing without any major complications. However, there are a series of complications related to this method that should be taken into consideration. Being misled by the radiological aspects of the fractures, the most certain way to classify a metacarpal shaft fracture is through exploratory surgery, even if in most of the cases the three radiological views are enough to establish the diagnosis. Abbreviations: DASH score = Disability of Arm, Shoulder and Hand score, TAM = Total Active Motion, MCP = metacarpal phalangeal joint, PIP = proximal inter phalangeal joint PMID:27974942

  2. Anterior augmentation plating of aseptic humeral shaft nonunions after intramedullary nailing.

    PubMed

    Gessmann, Jan; Königshausen, Matthias; Coulibaly, Marlon Osman; Schildhauer, Thomas Armin; Seybold, Dominik

    2016-05-01

    Humeral shaft nonunion after intramedullary nailing is a rare but serious complication. Treatment options include implant removal, open plating, exchange nailing and external fixation. The objective of this retrospective study was to determine whether augmentation plating without nail removal is feasible for treating a humeral shaft nonunion. Between 2002 and 2014, 37 patients (mean age 51, range 20-84 years) with aseptic humeral shaft nonunions prior to intramedullary nailing were treated with augmentation plating. The initial fractures had been fixed with retrograde nails (10 cases) or anterograde nails (27 cases). There were 34 atrophic nonunions and 3 hypertrophic nonunions. Nonunion treatment of all patients consisted of local debridement through an anterior approach to the humerus and anterior placement of the augmentation plates. Supplemental bone grafting was performed in all atrophic nonunion cases. All patients were followed until union was radiologically confirmed. Union was achieved in 36 patients (97 %) after a mean of 6 months (range 3-24 months). There was one case of iatrogenic median nerve palsy that showed complete spontaneous recovery 6 weeks postoperatively. One patient sustained a peri-implant stress fracture that was treated successfully by exchanging the augmentation plate to bridge the nonunion and the fracture. No infections or wound healing complications developed. At a mean follow-up of 14 months, all patients showed free shoulder and elbow motion and no restrictions in daily or working life. The results indicate that augmentation plating using an anterior approach is a safe and reliable option for humeral shaft nonunions after failed nailing, and the treatment has no substantial complications. Because the healing rates are similar to the standard technique of nail removal and fixation by compression or locking plates, we consider this technique to be an alternative choice for treatment.

  3. Nandrolone decanoate appears to increase bone callus formation in young adult rats after a complete femoral fracture.

    PubMed

    Guimarães, Ana Paula Franttini Garcia Moreno; Butezloff, Mariana Maloste; Zamarioli, Ariane; Issa, João Paulo Mardegan; Volpon, José Batista

    2017-11-01

    To evaluate the influence of nandrolone decanoate on fracture healing and bone quality in normal rats. Male rats were assigned to four groups (n=28/group): Control group consisting of animals without any intervention, Nandrolone decanoate (DN) group consisting of animals that received intramuscular injection of nandrolone decanoate, Fracture group consisting of animals with a fracture at the mid-diaphysis of the femur, and Fracture and nandrolone decanoate group consisting of animals with a femur fracture and treatment with nandrolone decanoate. Fractures were created at the mid-diaphysis of the right femur by a blunt trauma and internally fixed using an intramedullary steel wire. The DN was injected intramuscularly twice per week (10 mg/kg of body mass). The femurs were measured and evaluated by densitometry and mechanical resistance after animal euthanasia. The newly formed bone and collagen type I levels were quantified in the callus. The treated animals had longer femurs after 28 days. The quality of the intact bone was not significantly different between groups. The bone callus did show a larger mass in the treated rats. The administration of nandrolone decanoate did not affect the quality of the intact bone, but might have enhanced the bone callus formation.

  4. Biomechanical outcome of proximal femoral nail antirotation is superior to proximal femoral locking compression plate for reverse oblique intertrochanteric fractures: a biomechanical study of intertrochanteric fractures.

    PubMed

    Ma, Jian-Xiong; Wang, Jie; Xu, Wei-Guo; Yu, Jing-Tao; Yang, Yang; Ma, Xin-Long

    2015-01-01

    Reverse obliquity intertrochanteric fractures are a challenge for orthopedic surgeons. The optimal internal fixation for repairing this type of unstable intertrochanteric fractures remains controversial. This study aimed to compare the biomechanical properties in axial load and cyclical axial load of proximal femoral nail antirotation (PFNA) and proximal femoral locking compression plate (PFLCP) for fixation of reverse obliquity intertrochanteric fractures. Sixteen embalmed cadaver femurs were sawed to simulate reverse obliquity intertrochanteric fracture and instrumented with PFNA or PFLCP. Axial loads and axial cyclic loads were applied to the femoral head by an Instron tester. If the implant-femur constructs did not fail, axial failure load was added to the remaining implant-femur constructs. Mean axial stiffness for PFNA was 21.10% greater than that of PFLCP. Cyclic axial loading caused significantly less (p=0.022) mean irreversible deformation in PFNA (3.43 mm) than in PFLCP (4.34 mm). Significantly less (p=0.002) mean total deformation was detected in PFNA (6.16 mm) than in PFLCP (8.67 mm). For fixing reverse obliquity intertrochanteric fractures, PFNA is superior to PFLCP under axial load.

  5. Peri-prosthetic fractures around tumor endoprostheses: a retrospective analysis of eighteen cases.

    PubMed

    Barut, Nicolas; Anract, Philippe; Babinet, Antoine; Biau, David

    2015-09-01

    Tumour hip and knee endoprostheses have become the mainstay for reconstruction of patients with bone tumours. Fixation into host bone has improved over time. However, some patients present with a peri-prosthetic fracture over follow-up. The objective of this study was to analyse the mode of presentation and survival of implant after a peri-prosthetic fracture around a tumour endoprosthesis. Eighteen peri-prosthetic fractures (17 patients) were included. All patients were treated at a tertiary care center. There were 11 (65%) women; the median age at the time of fracture was 38 years old. All implants were cemented and all knee endoprostheses were fixed-hinge. Twelve (67%) fractures occurred after femoral resection and six (33%) fractures after proximal tibial resection. There were three femoral neck fractures (UCS C), three femoral shaft type C fractures, two femoral shaft type B1, one tibial shaft type B2, three tibial shaft type C, three ankle fractures (UCS C) and three patella fractures (UCS F). Two fractures were treated conservatively and 16 were operated on. Only one patient had the implant revised. There were eight (44%) failures over follow-up; none of the conservative treatment failed. The cumulative probability of failure for any reason was 27% (8-52) and 55% (22-79) at five and ten years, respectively. Peri-prosthetic fractures around massive endoprostheses are different from that of standard implants. There are more type C fractures; internal fixation is an attractive option at the time of presentation but the risk of revision over follow-up is high and patients should be informed accordingly.

  6. Specimen-specific modeling of hip fracture pattern and repair.

    PubMed

    Ali, Azhar A; Cristofolini, Luca; Schileo, Enrico; Hu, Haixiang; Taddei, Fulvia; Kim, Raymond H; Rullkoetter, Paul J; Laz, Peter J

    2014-01-22

    Hip fracture remains a major health problem for the elderly. Clinical studies have assessed fracture risk based on bone quality in the aging population and cadaveric testing has quantified bone strength and fracture loads. Prior modeling has primarily focused on quantifying the strain distribution in bone as an indicator of fracture risk. Recent advances in the extended finite element method (XFEM) enable prediction of the initiation and propagation of cracks without requiring a priori knowledge of the crack path. Accordingly, the objectives of this study were to predict femoral fracture in specimen-specific models using the XFEM approach, to perform one-to-one comparisons of predicted and in vitro fracture patterns, and to develop a framework to assess the mechanics and load transfer in the fractured femur when it is repaired with an osteosynthesis implant. Five specimen-specific femur models were developed from in vitro experiments under a simulated stance loading condition. Predicted fracture patterns closely matched the in vitro patterns; however, predictions of fracture load differed by approximately 50% due to sensitivity to local material properties. Specimen-specific intertrochanteric fractures were induced by subjecting the femur models to a sideways fall and repaired with a contemporary implant. Under a post-surgical stance loading, model-predicted load sharing between the implant and bone across the fracture surface varied from 59%:41% to 89%:11%, underscoring the importance of considering anatomic and fracture variability in the evaluation of implants. XFEM modeling shows potential as a macro-level analysis enabling fracture investigations of clinical cohorts, including at-risk groups, and the design of robust implants. © 2013 Published by Elsevier Ltd.

  7. Biologic fixation through bridge plating for comminuted shaft fracture of the clavicle: technical aspects and prospective clinical experience with a minimum of 12-month follow-up.

    PubMed

    Jung, Gu Hee; Park, Chang-Min; Kim, Jae-Do

    2013-12-01

    For comminuted shaft fracture of clavicle, the operative goal, aside from sound bone healing without complications of direct reduction, is maintenance of the original length in order to maintain the normal biomechanics of adjacent joint. Our bridge plating technique utilizing distraction through a lumbar spreader was expected to be effective for restoring clavicular length with soft tissue preservation. However, there are two disadvantages. First, there is more exposure to radiation compared to conventional plating; and second, it is difficult to control the rotational alignment. Despite these disadvantages, our technique has important benefits, in particular, the ability to preserve clavicular length without soft tissue injury around the fracture site.

  8. Proximal and distal alignment of normal canine femurs: A morphometric analysis.

    PubMed

    Kara, Mehmet Erkut; Sevil-Kilimci, Figen; Dilek, Ömer Gürkan; Onar, Vedat

    2018-05-01

    Many researchers are interested in femoral conformation because most orthopaedic problems of the long bones occur in the femur and its joints. The neck-shaft (NSA) and the anteversion (AVA) angles are good predictors for understanding the orientation of the proximal end of the femur. The varus (aLDFA) and procurvatum (CDFA) angles have also been used to understand the orientation of the distal end of the femur. The purposes of this study were to investigate the relationship between the proximal and distal angles of the femur and to compare the distal femoral angles in male and female dogs in order to investigate the sexual dimorphism. The measurements of normal CDFAs, which have not been previously reported, may also provide a database of canine distal femoral morphology. A total of 75 cleaned healthy femora from different breeds or mixed breed of dogs were used. The three-dimensional images were reconstructed from computed tomographic images. The AVA, NSA, aLDFA and CDFA were measured on the 3D images. The correlation coefficients were calculated among the measured angles. The distal femoral angles were also compared between male and female femora. The 95% confidence intervals of the AVA and the NSA were calculated to be 24.22°-29.50° and 144.97°-147.50°, respectively. The 95% confidence intervals of the aLDFA and the CDFA for all studied dogs were 92.62°-94.08° and 89.09°-91.94°, respectively. The NSA showed no correlation with either the aLDFA or CDFA. There was a weak inverse correlation between the AVA and CDFA and a weak positive correlation between the AVA and aLDFA. The differences in the aLDFA and CDFA measurements between male and female dog were not significant. In conclusion, femoral version, regardless of the plane, might have little influence on distal femoral morphology in normal dogs. Besides this, there is no evidence of a sexual dimorphism in the varus and procurvatum angles of the dog distal femur. The data from this study may be used in

  9. Periprosthetic Fractures Following Total Knee Arthroplasty

    PubMed Central

    Kim, Nam Ki

    2015-01-01

    Periprosthetic fractures after total knee arthroplasty may occur in any part of the femur, tibia and patella, and the most common pattern involves the supracondylar area of the distal femur. Supracondylar periprosthetic fractures frequently occur above a well-fixed prosthesis, and risk factors include anterior femoral cortical notching and use of the rotational constrained implant. Periprosthetic tibial fractures are frequently associated with loose components and malalignment or malposition of implants. Fractures of the patella are much less common and associated with rheumatoid arthritis, use of steroid, osteonecrosis and malalignment of implants. Most patients with periprosthetic fractures around the knee are the elderly with poor bone quality. There are many difficulties and increased risk of nonunion after treatment because reduction and internal fixation is interfered with by preexisting prosthesis and bone cement. Additionally, previous soft tissue injury is another disadvantageous condition for bone healing. Many authors reported good clinical outcomes after non-operative treatment of undisplaced or minimally displaced periprosthetic fractures; however, open reduction or revision arthroplasty was required in displaced fractures or fractures with unstable prosthesis. Periprosthetic fractures around the knee should be prevented by appropriate technique during total knee arthroplasty. Nevertheless, if a periprosthetic fracture occurs, an appropriate treatment method should be selected considering the stability of the prosthesis, displacement of fracture and bone quality. PMID:25750888

  10. Radiographic Review of Helical Blade Versus Lag Screw Fixation for Cephalomedullary Nailing of Low-Energy Peritrochanteric Femur Fractures: There is a Difference in Cutout.

    PubMed

    Stern, Lorraine C; Gorczyca, John T; Kates, Stephen; Ketz, John; Soles, Gillian; Humphrey, Catherine A

    2017-06-01

    To compare the rate of cutout of helical blades and lag screws in low-energy peritrochanteric femur fractures treated with a cephalomedullary nail (CMN). Retrospective review. Academic medical center. Overall, this study included 362 patients with an average age of 83 year old, a majority of whom were women, and had sustained a low-energy peritrochanteric femur fracture treated with a CMN. All patients had at least 3 months of clinical and radiographic follow, with an average follow-up of 11 months and a range of 3-88 months follow-up. Cephalomedullary nailing with the use of a helical blade or single lag screw for proximal fixation. Cutout of the helical blade or lag screw. Twenty-two cutouts occurred, 14 (15.1%) of 93 patients with helical blades and 8 (3.0%) of 269 patients with lag screws. Cutout with the helical blade was significantly more frequent than with the lag screw (P = 0.0001). The average tip-apex distance (TAD) was significantly greater for those patients who experienced cutout both for the helical blades (23.5 vs. 19.7 mm; P = 0.0194) and lag screws (24.5 vs. 20.0 mm; P = 0.0197). An absolute TAD predictive of cutout could not be determined. When the helical blade was used, implant cutout occurred at a significantly higher rate compared with lag screw fixation. There was not a threshold TAD that was predictive of cutout for either implant. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  11. Femoral Neck Anteversion and Neck Shaft Angles: Determination and their Clinical Implications in Fetuses of Different Gestational Ages.

    PubMed

    Souza, A D; Ankolekar, V H; Padmashali, S; Das, A; Souza, Asd; Hosapatna, M

    2015-07-01

    Precise anatomical assessment of femoral neck anteversion (FNA) and the neck shaft angles (NSA) would be essential in diagnosing the pathological conditions involving hip joint and its ligaments. The present study was undertaken on 48 fetal femurs to calculate the NSA and FNA in fetuses digitally. End on images of upper end of the femurs were taken for the estimation of FNA and a photograph in a perpendicular plane was taken to calculate the NSA. Microsoft Paint software was used to mark the points and Image J software was used to calculate the angles digitally. The FNA ranged from 17.08º to 33.97 º on right and 17.32 º to 45.08 º on left. The NSA ranged from 139.33 º to 124.91 º on right and 143.98 º to 123.8 º on left. Unpaired t test showed the FNA and NSA of femur did not vary significantly during the third trimester.

  12. Two new regions of interest to evaluate separately cortical and trabecular BMD in the proximal femur using DXA.

    PubMed

    Prevrhal, Sven; Meta, Margarita; Genant, Harry K

    2004-01-01

    To differentiate changes in trabecular and cortical bone density at a skeletal site bearing body weight, the main goal of this retrospective study was to develop and characterize two new regions of interest (ROIs) for DXA at the hip, one mainly focusing on trabecular bone and another mainly focusing on cortical bone. Specific aims were to maximize the precision of the ROIs and to characterize their usefulness for monitoring age-related bone loss and discriminating controls from fracture cases in a cross-sectional study population and to compare them with earlier ROIs designed by our group. The study used populations from two different previous studies conducted in our laboratory, with one comprising cohorts of healthy premenopausal women, healthy postmenopausal women, and postmenopausal osteoporotic women with at least one spinal fracture (Spine Fx Study) and the other one comprising two cohorts of age-matched postmenopausal women, in whom cases had sustained a hip fracture (Hip Fx study). The new ROI for trabecular bone (CIRCROI) tries to improve on the earlier custom-designed Central ROI, which was also targeted at trabecular bone. CIRCROI consists of an approximate largest circle that can fit inside the femoral proximal metaphysis without touching the superior and inferior endocortical walls. The new ROI for cortical bone (CORTROI) at a site bearing body weight is defined as a horizontal rectangular box crossing the femoral shaft below the lesser trochanter. CORTROI BMD cohort means were significantly higher than all other ROIs, and CIRCROI BMD cohort means were lower than standard ROIs with the exception of Ward's ROI. CIRCROI BMD was highly correlated with total femur BMD ( r=0.94) and Central BMD ( r=0.93), whereas CORTROI BMD correlations were lower (highest with total femur BMD ( r=0.86)). Fracture discrimination odds ratios (ORs) of all ROIs were significant for the Hip Fx Study, with CIRCROI BMD having the highest, and CORTROI BMD the lowest, OR (4.83 and

  13. In vivo impact testing on a lengthened femur with external fixation: a future option for the non-invasive monitoring of fracture healing?

    PubMed

    Mattei, Lorenza; Di Puccio, Francesca; Marchetti, Stefano

    2018-05-01

    Non-invasive methods for assessing fracture healing are crucial for biomedical engineers. An approach based on mechanical vibrations was tried out in the 1990s, but was soon abandoned due to insufficiently advanced technologies. The same approach is re-proposed in the present study in order to monitor the healing process of a lengthened femur with an external fixator. The pins screwed into the bone were exploited for the impact testing (IT) to excite the bone and capture its response. Transmission through the soft tissues was thus prevented, and the quality of the signals was improved. Impact tests were performed every three to four weeks for five months. Unfortunately, after seven weeks, some pins were removed due to infection, and thus, the system was modified. Two different configurations were considered: before and after pin removal. An additional configuration was examined in the last two sessions, when the fixator body was removed, while four pins were left in the femur. The evolution of the frequency response function and of the resonant frequencies of the system were analysed for the duration of the monitoring period. The IT results were compared to the indications provided by X-ray images. During the evolution of the callus from the soft phase to the woven bone, the resonant frequencies of the system were found to increase by approximately 2-3% per week. The largest increase (approx. 22%) was observed for the first resonant frequency. After formation of the woven bone, the vibratory response remained almost the same, suggesting that the healing assessment could be related to the relative variation in the resonant frequencies. The results presented support the application of the IT approach for fracture healing assessment. © 2018 The Author(s).

  14. The cam impinging femur has multiple morphologic abnormalities.

    PubMed

    Ellis, Andrew R; Noble, Philip C; Schroder, Steven J; Thompson, Matthew T; Stocks, Gregory W

    2011-09-01

    This study was performed to establish whether the "cam" impinging femur has a single deformity of the head-neck junction or multiple abnormalities. Average dimensions (anteversion angle, α angle of Notzli, β angle of Beaulé, normalized anterior head offset) were compared between normal and impinging femora. The results demonstrated that impinging femora had wider necks, larger heads, and decreased head-neck ratios. There was no difference in neck-shaft angle or anteversion angle. Forty-six percent of impinging femora had significant posterior head displacement (>2mm), which averaged 1.93 mm for the cam impinging group, and 0.78 mm for the normal group. In conclusion, surgical treatment limited to localized recontouring of the head-neck profile may fail to address significant components of the underlying abnormality. Copyright © 2011 Elsevier Inc. All rights reserved.

  15. One-stage lengthening using a locked nailing technique for distal femoral shaft nonunions associated with shortening.

    PubMed

    Wu, Chi-Chuan; Lee, Zhon-Liau

    2004-02-01

    To assess the effectiveness of a one-stage lengthening using a locked nail technique for the treatment of distal femoral shaft nonunions associated with shortening. Retrospective. University hospital. During a 6-year period, 36 distal femoral shaft nonunions associated with shortening (>1.5 cm) were treated by the one-stage lengthening technique. Indications for this technique were distal femoral shaft aseptic or quiescent infected nonunions, 1.5-5 cm shortening, and a fracture level suitable for the insertion of two distal locked screws. The surgical technique involved skeletal traction using the femoral condyle, local débridement, lengthening by fractures healed. The median union period was 4.5 months (range 3-6 months). Three fractures persistently failed to heal. One was treated successfully with exchange nailing, and the remaining two patients were followed annually and had no symptoms. At the latest follow-up, all 32 patients had achieved a satisfactory outcome. The average lengthening was 2.5 cm (range 1.5-3.5 cm). One-stage lengthening using the locked nailing technique to treat distal femoral shaft nonunions associated with shortening can achieve a high success rate and low complication rate. The key to successful treatment is the patient's complete cooperation with strictly protected weight bearing until the fracture has healed.

  16. [Multiple long bone fractures in a child with pycnodysostosis. A case report].

    PubMed

    Rojas, Paula I; Niklitschek, Nathia E; Sepúlveda, Matías F

    2016-06-01

    Fractures are an important entity to consider in pediatric patients. There are certain diseases in which bones fracture with a minimal trauma. Pycnodysostosis is an autosomal recessive unusual type of cráneo metaphyseal dysplasia, that presents frequently as fracture in a pathological bone. A 9 year old caucasian female, diagnosed with pycnodysostosis, was admitted with a right femur fracture as a result of a low energy trauma. Radiographic studies showed bilateral femur fractures, proximal fracture and non-union in antecurvatum of the left tibia. Pycnodysostosis is a rare disease, generally diagnosed at an early age by growth restriction, frequent fractures or fractures with low energy trauma. Therapy alternatives are limited, and no permanent cure has been developed. If a patient has dysmorphic facial features and fractures in a pathological bone, it is important to suspect bone dysplasia, such as pycnodysostosis and its differential diagnoses. Sociedad Argentina de Pediatría.

  17. Prophylactic augmentation of the proximal femur: an investigation of two techniques.

    PubMed

    Raas, Christoph; Hofmann-Fliri, Ladina; Hörmann, Romed; Schmoelz, Werner

    2016-03-01

    Osteoporotic hip fractures are an increasing problem in an ageing population. They result in high morbidity, mortality and high socioeconomic costs. For patients with poor bone quality, prophylactic augmentation of the proximal femur might be an option for fracture prevention. In two groups of paired human femora the potential of limited polymethyl-methacrylate (PMMA) augmentation (11-15 ml) in a V-shape pattern and the insertion of a proximal femur nail antirotation (PFNA) blade were investigated. The testing was carried out pair wise simulating the single leg stand. The untreated femur in each pair served as control. An axial load was applied until failure. Load displacement parameters and temperature increase during the augmentation process were recorded. In the PMMA group no significant difference was found between the augmented and non-augmented specimen concerning load to failure (p = 0.35) and energy to failure (p = 0.9). A median temperature increase of 9.5 °C was observed in the augmented specimen. A significant correlation was found between the amount of applied PMMA and the temperature increase (Cor. Coef. = 0.82, p = 0.042). In the PFNA group, a significant decrease of load to failure and a non-significant decrease of energy to failure were observed (p = 0.037 and p = 0.075). Limited V-shaped PMMA augmentation and PFNA blade insertion did not show any improvement in failure load or energy to failure. Volumes of up to 15 ml PMMA did not cause a critical surface temperature increase.

  18. Augmentation plating in management of failed femoral nailing.

    PubMed

    Verma, Rahul; Sharma, Pulak; Gaur, Sanjiv

    2017-08-01

    Non-union following interlocking nailing is a troubling complication in treatment of shaft femur fractures. There is no clear consensus on the treatment of this problem. This research was undertaken to study the role of augmentation plating combined with exchange nailing in such cases. A prospective clinical study was undertaken from January 2010 to December 2015. Patients with aseptic femoral shaft non-union, with or without implant failure following intramedullary nailing were included in the study. Augmentation plating combined with Exchange Nailing with a 4.5mm LCP was done. Fifteen patients (nine male and six female) with an average age of 43.7 years (range 18-67 years) were treated. Average timing from the first surgery was 7.3 months. Complete clinical and radiological union was achieved in all cases in a mean duration of 5.2 months. Average duration of follow up was 12.6 months. All the patients retained the preoperative hip and knee range of motion till the last follow up. Augmentation plating combined with exchange nailing in non-unions following intramedullary nailing of femur shaft fractures is a reasonably good and effective procedure with a very high success rate. © 2017 Elsevier Ltd. All rights reserved.

  19. Secondary prevention of osteoporosis in non-neck of femur fragility fractures: is it value for money? A retrospective, prospective and cross-sectional cohort study.

    PubMed

    Mettyas, Tamer; Carpenter, Clare

    2013-12-01

    Osteoporosis is one of the commonest bone diseases in which bone fragility is increased. Over 300,000 patients present to hospitals in the UK with fragility fractures each year, with medical and social care costs - most of which relate to hip fracture care - at around £2 billion. The number of these fractures rises by 2% a year. The 30 days mortality is 10% and 30% at 1 year. The purpose of this study is to review the current practice according to NICE and BOA guidelines of secondary prevention of osteoporosis and to suggest changes to these guidelines. Patients over 50 years old admitted as inpatients to our facility with non-neck-of-femur (NOF) fragility fractures in March and September 2008 were studied. Retrospectively (March), looking for risk factors and if treated or not, then prospectively (September), after introducing the new trauma admission sheet. Also cross-sectional study was performed by comparing the services provided for NOF and non-NOF fragility fractures in September. Two-sample t test is used to compare between percentages. Twenty-nine percent of fragility fractures are non-NOF fractures with a mean age of 70 years, while the remaining 71% are NOF fractures with a mean age of 80 years. There is a great difference in the care provided to these patients: non-NOF fragility fractures got less attention for assessment of osteoporosis (25%) and obtained less interest in investigations by medical staff (11%) and, finally, less intentions to treat osteoporosis (35%), compared to NOF fractures in which 35% of cases were assessed, 47% were investigated and 71% were treated for osteoporosis. Twenty-five percent of NOF fracture patients were found to have previous fragility fractures in the preceding years, while only 6% were on osteoporosis treatment before the fracture. Osteoporosis (a new epidemic) is the most common disease of the bone and its incidence is rising rapidly as the population ages. Though treatable, it is often left untreated. We believe

  20. PROSPECTIVE ASSESSMENT OF THE CLINICAL, RADIOGRAPHIC AND FUNCTIONAL EVOLUTION OF TREATMENT FOR UNSTABLE TROCHANTERIC FRACTURES OF THE FEMUR USING A CEPHALOMEDULLARY NAIL

    PubMed Central

    Borger, Richard Armelin; Borger, Frederico Araújo; Pires de Araújo, Rodrigo; Pereira, Thiago Ferreira Nunes; Queiroz, Roberto Dantas

    2015-01-01

    To assess the clinical, radiological and functional evolution of osteosynthesis using a cephalomedullary nail, in unstable trochanteric fractures of the femur, over a one-year postoperative follow-up. Methods: Fourteen men and 23 women of mean age 77.7 years were evaluated. Twenty-seven of them had fractures classified as AO/ASIF 31A2 and ten as 31A3. The patients were evaluated clinically, radiologically and functionally one week, two weeks, one month, two months, six months and one year after the operation. Results: The clinical complications comprised five cases of death, one case of calcaneal ulcer, one case of acute arterial obstruction and two cases of deep vein thrombosis. The radiographic evaluation showed that the mean cervicodiaphyseal angle in the immediate postoperative period was 132.5°. The mean tip-apex index was 22.8 mm. After one year, the mean cervicodiaphyseal angle was 131.7°. Fracture consolidation was seen in all the patients six months after the operation, except in one case that presented cut-out. There were no cases of fracture below the implant. The functional evaluation using the Harris score after one year showed a mean of 69.3 points. The evaluation of walking progress showed that after one year, 40.6% of the patients had the same ability to walk that they had before the fracture. The visual analogue pain scale showed that a significant decrease in pain complaints occurred, going from 5.19 in the first week to 2.25 after 1 year. Conclusion: Osteosynthesis using a cephalomedullary nail resulted in low rates of clinical and mechanical complications and adequate functional outcomes. PMID:27027025

  1. PROSPECTIVE ASSESSMENT OF THE CLINICAL, RADIOGRAPHIC AND FUNCTIONAL EVOLUTION OF TREATMENT FOR UNSTABLE TROCHANTERIC FRACTURES OF THE FEMUR USING A CEPHALOMEDULLARY NAIL.

    PubMed

    Borger, Richard Armelin; Borger, Frederico Araújo; Pires de Araújo, Rodrigo; Pereira, Thiago Ferreira Nunes; Queiroz, Roberto Dantas

    2011-01-01

    To assess the clinical, radiological and functional evolution of osteosynthesis using a cephalomedullary nail, in unstable trochanteric fractures of the femur, over a one-year postoperative follow-up. Fourteen men and 23 women of mean age 77.7 years were evaluated. Twenty-seven of them had fractures classified as AO/ASIF 31A2 and ten as 31A3. The patients were evaluated clinically, radiologically and functionally one week, two weeks, one month, two months, six months and one year after the operation. The clinical complications comprised five cases of death, one case of calcaneal ulcer, one case of acute arterial obstruction and two cases of deep vein thrombosis. The radiographic evaluation showed that the mean cervicodiaphyseal angle in the immediate postoperative period was 132.5°. The mean tip-apex index was 22.8 mm. After one year, the mean cervicodiaphyseal angle was 131.7°. Fracture consolidation was seen in all the patients six months after the operation, except in one case that presented cut-out. There were no cases of fracture below the implant. The functional evaluation using the Harris score after one year showed a mean of 69.3 points. The evaluation of walking progress showed that after one year, 40.6% of the patients had the same ability to walk that they had before the fracture. The visual analogue pain scale showed that a significant decrease in pain complaints occurred, going from 5.19 in the first week to 2.25 after 1 year. Osteosynthesis using a cephalomedullary nail resulted in low rates of clinical and mechanical complications and adequate functional outcomes.

  2. [Recent advances in treatment of aseptic femoral shaft nonunion].

    PubMed

    Zhang, Wei; Chen, Hua; Tang, Peifu

    2018-05-01

    To review the recent advances in treatment of aseptic femoral shaft nonunion. The clinical studies about the treatments of aseptic femoral shaft nonunion in recent years were widely reviewed and analyzed. There are several surgical methods for aseptic femoral shaft nonunion. Due to uncertain clinical outcome, dynamization of nail should be carefully selected. The exchange nailing is suitable for the hypertrophic nonunion of the isthmal femoral shaft fracture. The exchange lateral plating is suitable for nonunion with obvious malformation. However, wave plate or dual plate should be chosen when the bone nonuinon is combined with the medial defect. The augmentation plating improves the success rate of nailing for femoral shaft nonunion, but it should be carefully selected for patients with obvious deformity or bone defect. Ilizarov technique is suitable for various bone nonunion, especially with complicated or large segmental bone defects. Induced membrane technique is also an important method for the treatment of bone nonunion with large bone defects. The clinical efficacy of the blocking screw remains to be supported by further evidence. Biological stimulants are mainly used for atrophic nonunion, and the clinical efficacy of them alone are still controversial. Due to lack of comparative studies between different surgical methods, the orthopedist should choose the appropriate treatment according to the individual situations of the patient and the types of bone nonunion.

  3. Fatigue Fractures

    PubMed Central

    Morris, James M.

    1968-01-01

    Fatigue (or stress) fracture of bone in military recruits has been recognized for many years. Most often it is a metatarsal bone that is involved but the tarsal bones, calcaneus, tibia, fibula, femur, and pelvis are occasionally affected. Reports of such fractures in the ribs, ulna and vertebral bodies may be found in the literature. In recent years, there has been increasing awareness of the occurrence of fatigue fractures in the civilian population. Weekend sportsmen, athletes in an early phase of training, and persons engaged in unaccustomed, repetitive, vigorous activity are potential victims of such a fracture. The signs and symptoms, roentgenographic findings, treatment and etiology of fatigue fractures are dealt with in this presentation. ImagesFigure 1.Figure 2.Figure 3.Figure 4.Figure 5.Figure 6. PMID:5652745

  4. Unexpected timely fracture union in matrix metalloproteinase 9 deficient mice.

    PubMed

    Yuasa, Masato; Saito, Masanori; Molina, Cesar; Moore-Lotridge, Stephanie N; Benvenuti, Michael A; Mignemi, Nicholas A; Okawa, Atsushi; Yoshii, Toshitaka; Schwartz, Herbert S; Nyman, Jeffry S; Schoenecker, Jonathan G

    2018-01-01

    Immediately following a fracture, a fibrin laden hematoma is formed to prevent bleeding and infection. Subsequently, the organized removal of fibrin, via the protease plasmin, is essential to permit fracture repair through angiogenesis and ossification. Yet, when plasmin activity is lost, the depletion of fibrin alone is insufficient to fully restore fracture repair, suggesting the existence of additional plasmin targets important for fracture repair. Previously, activated matrix metalloproteinase 9 (MMP-9) was demonstrated to function in fracture repair by promoting angiogenesis. Given that MMP-9 is a defined plasmin target, it was hypothesized that pro-MMP-9, following plasmin activation, promotes fracture repair. This hypothesis was tested in a fixed murine femur fracture model with serial assessment of fracture healing. Contrary to previous findings, a complete loss of MMP-9 failed to affect fracture healing and union through 28 days post injury. Therefore, these results demonstrated that MMP-9 is dispensable for timely fracture union and cartilage transition to bone in fixed femur fractures. Pro-MMP-9 is therefore not a significant target of plasmin in fracture repair and future studies assessing additional plasmin targets associated with angiogenesis are warranted.

  5. Whole-body vibration improves fracture healing and bone quality in rats with ovariectomy-induced osteoporosis.

    PubMed

    Butezloff, Mariana Maloste; Zamarioli, Ariane; Leoni, Graziela Bianchi; Sousa-Neto, Manoel Damião; Volpon, Jose Batista

    2015-11-01

    To investigate the effect of vibration therapy on the bone callus of fractured femurs and the bone quality of intact femurs in ovariectomized rats. Fifty-six rats aged seven weeks were divided into four groups: control with femoral fracture (CON, n=14), ovariectomized with femoral fracture (OVX, n=14), control with femoral fracture plus vibration therapy (CON+VT, n=14), and ovariectomized with femoral fracture plus vibration therapy (OVX+VT, n=14). Three months after ovariectomy or sham surgery, a complete fracture was produced at the femoral mid-diaphysis and stabilized with a 1-mm-diameter intramedullary Kirschner wire. X-rays confirmed the fracture alignment and fixation. Three days later, the VT groups underwent vibration therapy (1 mm, 60 Hz for 20 minutes, three times per week for 14 or 28 days). The bone and callus quality were assessed by densitometry, three-dimensional microstructure, and mechanical test. Ovariectomized rats exhibited a substantial loss of bone mass and severe impairment in bone microarchitecture, both in the non-fractured femur and the bone callus. Whole-body vibration therapy exerted an important role in ameliorating the bone and fracture callus parameters in the osteoporotic bone. Vibration therapy improved bone quality and the quality of the fracture bone callus in ovariectomized rats.

  6. The Treatment of Mid-shaft Clavicle Fractures

    PubMed Central

    Sang, Qing-Hua; Gou, Zhi-Gang; Zheng, Hua-Yong; Yuan, Jing-Tao; Zhao, Jian-Wen; He, Hong-Ying; Liu, Chuang; Liu, Zhi

    2015-01-01

    Objective: Through reviewing the relevant literature from the past decades, to summarize the assessment and management of fractures of the clavicle, and provide an overview of the clinical results of a range of treatment options. Data Sources: The data analyzed in this review are mainly from articles included in PubMed and EMBASE, published from 1960 to 2015. Study Selection: Studies involving assessment of fractures of the clavicle were reviewed. Further literatures were gathered regarding the conservative and surgical treatment of these fractures, including the methods of fixation and the surgical approaches used. Both conservative and surgical treatments were then compared and contrasted. Results: Through retrieving and reading the abstract, a total of 42 representative articles were selected, which covered all aspects of the conservative treatment and surgical treatment, and compared the advantages and disadvantages of different treatment options. Conclusions: Although the majority of recent data suggest that surgery may be more appropriate as it improves functional outcome and reduces the risk of complications, we recommend that the treatment should be individually assessed. PMID:26521795

  7. Segmentation of radiographic images under topological constraints: application to the femur.

    PubMed

    Gamage, Pavan; Xie, Sheng Quan; Delmas, Patrice; Xu, Wei Liang

    2010-09-01

    A framework for radiographic image segmentation under topological control based on two-dimensional (2D) image analysis was developed. The system is intended for use in common radiological tasks including fracture treatment analysis, osteoarthritis diagnostics and osteotomy management planning. The segmentation framework utilizes a generic three-dimensional (3D) model of the bone of interest to define the anatomical topology. Non-rigid registration is performed between the projected contours of the generic 3D model and extracted edges of the X-ray image to achieve the segmentation. For fractured bones, the segmentation requires an additional step where a region-based active contours curve evolution is performed with a level set Mumford-Shah method to obtain the fracture surface edge. The application of the segmentation framework to analysis of human femur radiographs was evaluated. The proposed system has two major innovations. First, definition of the topological constraints does not require a statistical learning process, so the method is generally applicable to a variety of bony anatomy segmentation problems. Second, the methodology is able to handle both intact and fractured bone segmentation. Testing on clinical X-ray images yielded an average root mean squared distance (between the automatically segmented femur contour and the manual segmented ground truth) of 1.10 mm with a standard deviation of 0.13 mm. The proposed point correspondence estimation algorithm was benchmarked against three state-of-the-art point matching algorithms, demonstrating successful non-rigid registration for the cases of interest. A topologically constrained automatic bone contour segmentation framework was developed and tested, providing robustness to noise, outliers, deformations and occlusions.

  8. [Proximal femoral fractures in the elderly: pathogenesis, sequelae, interventions].

    PubMed

    Runge, M; Schacht, E

    1999-08-01

    Hip fractures are a health problem of paramount importance for the individual and society. They are associated with a sharp increase of the incidence of immobility, dependency, nursing home placement, and death. In Germany, more than 100,000 elderly suffer a hip fracture every year. 90% of fractures of the proximal femur result from a fall with an impact near the hip. The kinetic energy of a fall from standing height without successful protective reactions is far above the fracture threshold of a femur in a man aged 70 and older, regardless of osteoporosis and sex. Therefore, propensity to fall and mechanisms of falling are more important in the pathogenesis of hip fracture than bone mineral density alone. The combination of age-associated gait and balance disorders, which increase the probability of falls, and age-related decreasing strength of the femur is responsible for the high incidence of hip fractures. Besides the interventions to reduce the fall frequency it is possible to decrease the number of hip fractures by a passive protection of the trochanter. An energy-shunting protector (crash helmet-like, hip padding) has been developed by Lauritzen and Lund (safehip). The protector consists of two stiff shells, sewn into special undergarment. The shells disperse the impact away from the trochanter to soft tissue, and increase the area of contact. A controlled study among nursing home residents has demonstrated a relative risk of hip fracture of 0.44 (95% CC 0.21 to 0.94) in the intervention group, i.e., the protector has reduced the number of hip fractures by more than a half. No hip fracture has happened during use of the protector. Using the protector can improve self-confidence and diminish self-restraint of physical activity, which is not rarely caused by fear of falling. Further investigations of compliance are necessary.

  9. Direct medical costs attributable to peripheral fractures in Canadian post-menopausal women.

    PubMed

    Bessette, L; Jean, S; Lapointe-Garant, M-P; Belzile, E L; Davison, K S; Ste-Marie, L G; Brown, J P

    2012-06-01

    This study determined the cost of treating fractures at osteoporotic sites (except spine fractures) for the year following fracture. While the average cost of treating a hip fracture was the highest of all fractures ($46,664 CAD per fracture), treating other fractures also accounted for significant expenditures ($5,253 to $10,410 CAD per fracture). This study aims to determine the mean direct medical cost of treating fractures at peripheral osteoporotic sites in the year post-fracture (through 2 years post-hip fracture). Health administrative databases from the province of Quebec, Canada were used to estimate the cost of treating peripheral fractures at osteoporotic sites for the year following fracture (through 2 years for hip fractures). Included in costs analyses were physician claims, emergency and outpatient clinic costs, hospitalization costs, and subsequent costs for treatment of complications. A total of 15,827 patients (mean age 72 years) who suffered one fracture at an osteoporotic site had data for analyses. Hip/femur fractures had the highest rate of hospital stays related to fracture (91%) and the highest rate of hospital stays associated with a post-fracture complication (8%). In the year following fracture, the mean (SD) costs (2009 Canadian dollars) of treating acute fractures and post-fracture complications were: hip/femur fracture $46,664 ($43,198), wrist fracture $5,253 ($18,982), and fractures at other peripheral sites $10,410 ($27,641). The average (SD) cost of treating post-fracture complications at the hip/femur in the second year post-fracture was $1,698 ($12,462). Hospitalizations associated with the fracture accounted for 88% of the total cost of fracture treatment. The treatment of hip fractures accounts for a significant proportion of the costs associated with the treatment of peripheral osteoporotic fractures. Interventions to reduce the incidence of fractures, particularly hip fractures, would result in significant cost savings to the

  10. A Novel Computer-Aided Approach for Parametric Investigation of Custom Design of Fracture Fixation Plates.

    PubMed

    Chen, Xiaozhong; He, Kunjin; Chen, Zhengming

    2017-01-01

    The present study proposes an integrated computer-aided approach combining femur surface modeling, fracture evidence recover plate creation, and plate modification in order to conduct a parametric investigation of the design of custom plate for a specific patient. The study allows for improving the design efficiency of specific plates on the patients' femur parameters and the fracture information. Furthermore, the present approach will lead to exploration of plate modification and optimization. The three-dimensional (3D) surface model of a detailed femur and the corresponding fixation plate were represented with high-level feature parameters, and the shape of the specific plate was recursively modified in order to obtain the optimal plate for a specific patient. The proposed approach was tested and verified on a case study, and it could be helpful for orthopedic surgeons to design and modify the plate in order to fit the specific femur anatomy and the fracture information.

  11. Should patients with a hip or femur fracture sustained abroad be repatriated for surgery?

    PubMed

    Graf, Stefan August; Zimmermann, Heinz; Albrecht, Roland; Roggenmoser, Philipp

    2013-10-25

    To investigate the clinical outcome of patients with hip or femur fractures sustained while travelling, depending on the place where surgery was performed (abroad or in Switzerland). This was an ambispective cohort study of 90 patients in two groups. Outcome measures were: number and type of complications, impairment of walking ability at six months compared to the preoperative state, and chronic pain with ongoing use of analgesic medication at six months A total of 62 patients were transported to be operated on in Switzerland, and 28 patients received their surgery abroad. Age and gender distribution of the two groups were comparable, as was comorbidity status. A total of 64% of patients operated on abroad suffered one or more complications, as compared with 37% of patients operated on in Switzerland (p = 0.01). Logistical regression showed no evidence of an association between the variables investigated as possible confounding factors and the outcome, the place where surgery was performed (abroad or at home), was the only predictor of complications in general and of a reoperation in particular (95% confidence intervals 1.55-13.7 and 1.39-41.25, respectively). When compared with their preoperative state, 89% of patients operated on abroad reported some postoperative walking impairment, compared with 57% of patients operated on in Switzerland (p = 0.004). A total of 59% of patients operated on abroad had to use analgesic medication intermittently or regularly six months after surgery, as compared with 35% of patients operated on in Switzerland (p = 0.03). Swiss patients with hip or femoral fractures sustained while travelling in a foreign country had fewer complications and a better functional outcome if repatriated and operated on in Switzerland than if operated on abroad. The reasons for this unexpected result remain unclear. Medical, ethnic and psychological factors could well play a part. These results need further clarification and should be tested in larger

  12. The fracture sites of atypical femoral fractures are associated with the weight-bearing lower limb alignment.

    PubMed

    Saita, Yoshitomo; Ishijima, Muneaki; Mogami, Atsuhiko; Kubota, Mitsuaki; Baba, Tomonori; Kaketa, Takefumi; Nagao, Masashi; Sakamoto, Yuko; Sakai, Kensuke; Kato, Rui; Nagura, Nana; Miyagawa, Kei; Wada, Tomoki; Liu, Lizu; Obayashi, Osamu; Shitoto, Katsuo; Nozawa, Masahiko; Kajihara, Hajime; Gen, Hogaku; Kaneko, Kazuo

    2014-09-01

    Atypical femoral fractures (AFFs) are stress-related fractures that are speculated to associate with long-term treatment with bisphosphonates for osteoporosis. A history of AFF is a high risk factor for the development of a subsequent AFF in the same location of the contralateral femur, suggesting that a patient's individual anatomical factor(s) are related to the fracture site of AFFs. In this study, we investigated the radiographs of fourteen AFFs (four bilateral fractures among ten patients) treated at six hospitals associated with our university between 2005 and 2010. The fracture site and standing femorotibial angle (FTA), which reflects the mechanical axis of the lower limb, were measured on weight-bearing lower limb radiographs. The fracture site and FTA of patients with typical femoral fractures (TFF) were compared to those of patients with AFFs. The correlations were examined using Spearman's rank correlation coefficients. The fracture locations in the femora were almost the same in the patients with bilateral AFFs. There was a positive correlation between the fracture site and the standing FTA in the patients with AFFs (r=0.82, 95% confidence interval; 0.49 to 0.94), indicating that the larger the standing FTA (varus alignment), the more distal the site of the fracture in the femur. The FTA of the patients with atypical diaphyseal femoral fracture were significantly larger compared to that of those with not only atypical subtrochanteric fractures but also TFFs. In conclusion, the fracture sites of AFFs are associated with the standing lower limb alignment, while those of TFFs are not. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Minimally Invasive Osteosynthesis with a Bridge Plate Versus a Functional Brace for Humeral Shaft Fractures: A Randomized Controlled Trial.

    PubMed

    Matsunaga, Fabio Teruo; Tamaoki, Marcel Jun Sugawara; Matsumoto, Marcelo Hide; Netto, Nicola Archetti; Faloppa, Flavio; Belloti, Joao Carlos

    2017-04-05

    Nonoperative treatment has historically been considered the standard for fractures of the shaft of the humerus. Minimally invasive bridge-plate osteosynthesis for isolated humeral shaft fractures has been proven to be a safe technique, with good and reproducible results. This study was designed to compare clinical and radiographic outcomes between patients who had been treated with bridge plate osteosynthesis and those who had been managed nonoperatively with a functional brace. A prospective randomized trial was designed and included 110 patients allocated to 1 of 2 groups: surgery with a bridge plate or nonoperative treatment with a functional brace. The primary outcome was the Disabilities of the Arm, Shoulder and Hand (DASH) score at 6 months. The score on the Short Form-36 (SF-36) life-quality questionnaire, complications of treatment, Constant-Murley score for the shoulder, pain level, and radiographic results were assessed as secondary outcomes. Participants were assessed at 2 weeks; 1, 2, and 6 months; and 1 year after the interventions. The mean DASH score of the bridge plate group was statistically superior to that of the functional brace group (mean scores, 10.9 and 16.9, respectively; p = 0.046) only at 6 months. The bridge plate group also had a significantly more favorable nonunion rate (0% versus 15%) and less mean residual angular displacement seen on the anteroposterior radiograph (2.0° versus 10.5°) (both p < 0.05). No difference between the groups was detected with regard to the SF-36 score, pain level, Constant-Murley score, or angular displacement seen on the lateral radiograph. This trial demonstrates that, compared with functional bracing, surgical treatment with a bridge plate has a statistically significant advantage, of uncertain clinical benefit, with respect to self-reported outcome (DASH score) at 6 months, nonunion rate, and residual deformity in the coronal plane as seen on radiographs. Therapeutic Level I. See Instructions for

  14. The direct and indirect costs of long bone fractures in a working age US population.

    PubMed

    Bonafede, Machaon; Espindle, Derek; Bower, Anthony G

    2013-01-01

    Information regarding the burden of fractures is limited, especially among working age patients. The objective of this study was to evaluate the direct and indirect costs associated with long bone fractures in a working age population using real-world claims data. This was a claims-based retrospective analysis, comparing adult patients in the 6 months before and 6 months after a long bone fracture between 1/1/2001 and 12/31/2008 using the MarketScan Research Databases. Outcomes included direct medical costs and utilization, as well as work absenteeism and short term disability, which was available for a sub-set of the patients. Observed and adjusted incremental costs (i.e., the difference in costs before and after a fracture) were evaluated and reported in 2008 US$. A total of 208,094 patients with at least one fracture were included in the study. Six, mutually exclusive fracture cohorts were evaluated: tibia shaft (n = 49,839), radius (n = 97,585), hip (n = 11,585), femur (n = 6788), humerus (n = 29,884), and those with multiple long bone fractures (n = 12,413). Average unadjusted direct costs in the 6-months before a long bone fracture ranged from $3291 (radius) to $12,923 (hip). The average incremental direct cost increase in the 6-months following a fracture ranged from $5707 (radius) to $39,041 (multiple fractures). Incremental absenteeism costs ranged from $950 (radius) to $2600 (multiple fractures), while incremental short-term disability costs ranged from $2050 (radius) to $4600 (multiple fractures). The results of this study indicate that long bone fractures are costly, both in terms of direct medical costs and lost productivity. Workplace absences and short-term disability represent a significant component of the burden of long bone fractures. These results may not be generalizable to all patients with fractures in the US, and do not reflect the burden of undiagnosed or sub-clinical fractures.

  15. The effect of lower limb rehabilitation gymnastics on postoperative rehabilitation in elderly patients with femoral shaft fracture: A retrospective case-control study.

    PubMed

    Yang, Si-Dong; Ning, Sheng-Hua; Zhang, Li-Hong; Zhang, Ying-Ze; Ding, Wen-Yuan; Yang, Da-Long

    2016-08-01

    The purpose of this study was to explore the effect of lower limb rehabilitation gymnastics on postoperative rehabilitation in elderly patients with femoral shaft fracture after undergoing intramedullary nail fixation surgery.We collected medical records of elderly patients aged ≥ 60 years with femoral shaft fracture between 03/2010 and 03/2015 in Longyao County Hospital. Totally, 160 patients were identified and divided into the intervention group (n = 80) and the control group (n = 80). During the postoperative period, the intervention group received lower limb rehabilitation gymnastics treatment for 3 months, but the control group did not. All patients were routinely asked to return hospital for a check in the 1st postoperative week, as well as the 2nd week, the 1st month, and the 3rd month, after surgery. The clinical rehabilitation effect was evaluated by checking lower limb action ability, detecting the lower limb deep venous thrombosis (DVT), scoring muscle strength of quadriceps and visual analog scale (VAS) score, and performing satisfaction survey.At the 1st week and 2nd week after surgery, the clinical rehabilitation effect in the intervention group was better regarding lower limb action ability, lower limb DVT, muscle strength of quadriceps, VAS score, and patient satisfaction, as compared with the control group. However, there was no significant difference at the 1st month and the 3rd month after surgery when comparing the intervention group to the control group.In the early postoperative stage, lower limb rehabilitation gymnastics can effectively improve the recovery of lower limb function, beneficial to reducing postoperative complications such as lower limb DVT and muscle atrophy, and increasing patient satisfaction rate.

  16. Mineral to matrix ratio determines biomaterial and biomechanical properties of rat femur--application of Fourier transform infrared spectroscopy.

    PubMed

    Takata, Shinjiro; Yonezu, Hiroshi; Shibata, Akira; Enishi, Tetsuya; Sato, Nori; Takahashi, Mitsuhiko; Nakao, Shigetaka; Komatsu, Koji; Yasui, Natsuo

    2011-08-01

    We studied the changes of biomaterial and biomechanical properties of the rat femur during development. Thirty male Wistar rats were allocated to 6 groups: aged 6 weeks (n=5), 9 weeks (n=5), 12 weeks (n=5), 15 weeks (n=5), 24 weeks (n=5), and 36 weeks (n=5). The mineral to matrix ratio (M/M ratio) of rat femur by Fourier transform infrared spectroscopy was 0.97 ± 0.10 at the age of 6 weeks, and reached the maximum of 1.52 ± 0.17 at the age of 36 weeks. Total bone mineral density (BMD) by peripheral quantitative computed tomography of the femoral shaft aged 6 weeks was 479.1 ± 58.7 mg/cm(3), and reached the maximum of 1022.2 ± 42.3 mg/cm(3) at the age of 36 weeks. The ultimate load to failure of the femur of the rat aged 6 weeks by the three-point bending test was 29.6 ± 6.1 N. At the age of 36 weeks, the ultimate load to failure of the rat femur increased to the maximum of 283.5 ± 14.7 N. The results showed that the M/M ratio increased with development as total BMD and bone strength increased. The results suggest that the M/M ratio is one of the determinants of the biomaterial and biomechanical properties of bone.

  17. Adult periarticular locking plates for the treatment of pediatric and adolescent subtrochanteric hip fractures.

    PubMed

    Sanders, Samuel; Egol, Kenneth A

    2009-01-01

    Two cases are presented in which adult, precontoured, lower-extremity periarticular locking plates were utilized for fixation of subtrochanteric femur fractures in pediatric patients. Recognition of the fact that a distal tibial locking plate in a small child and a proximal tibial locking plate in an adolescent anatomically ft the proximal femur in each case may provide a surgeon treating subtrochanteric hip fractures in this population increased options for operative stabilization.

  18. Bent shaft motor

    DOEpatents

    Benavides, Gilbert L.

    1998-01-01

    A nonelectromagnetic motor comprising a base, a bent shaft which is rotable relative to the base wherein the bent shaft comprises a straight portion aligned with a main axis and an offset portion that is offset with respect to the main axis; and a drive means for driving the offset portion of the bent shaft along a generally circular path in a plane perpendicular to the main axis to rotate the bent shaft. The bent shaft and drive means for driving the bent shaft can be selected from piezoelectric, magnetostrictive, rheological and shape memory alloys. The drive means of the nonelectromagnetic motor can additionally comprise a shell which shell surrounds and houses the bent shaft and precesses or gyrates which in turn causes the bent drive shaft to rotate. The nonelectromagnetic motor does not rely on friction for the application of torque upon a rotor.

  19. Bent shaft motor

    DOEpatents

    Benavides, G.L.

    1998-05-05

    A nonelectromagnetic motor comprising a base, a bent shaft which is rotatable relative to the base wherein the bent shaft comprises a straight portion aligned with a main axis and an offset portion that is offset with respect to the main axis; and a drive means for driving the offset portion of the bent shaft along a generally circular path in a plane perpendicular to the main axis to rotate the bent shaft. The bent shaft and drive means for driving the bent shaft can be selected from piezoelectric, magnetostrictive, rheological and shape memory alloys. The drive means of the nonelectromagnetic motor can additionally comprise a shell which shell surrounds and houses the bent shaft and precesses or gyrates which in turn causes the bent drive shaft to rotate. The nonelectromagnetic motor does not rely on friction for the application of torque upon a rotor. 11 figs.

  20. Lower Trabecular Volumetric BMD at Metaphyseal Regions of Weight-Bearing Bones is Associated With Prior Fracture in Young Girls

    PubMed Central

    Farr, Joshua N; Tomás, Rita; Chen, Zhao; Lisse, Jeffrey R; Lohman, Timothy G; Going, Scott B

    2011-01-01

    Understanding the etiology of skeletal fragility during growth is critical for the development of treatments and prevention strategies aimed at reducing the burden of childhood fractures. Thus we evaluated the relationship between prior fracture and bone parameters in young girls. Data from 465 girls aged 8 to 13 years from the Jump-In: Building Better Bones study were analyzed. Bone parameters were assessed at metaphyseal and diaphyseal sites of the nondominant femur and tibia using peripheral quantitative computed tomography (pQCT). Dual-energy X-ray absorptiometry (DXA) was used to assess femur, tibia, lumbar spine, and total body less head bone mineral content. Binary logistic regression was used to evaluate the relationship between prior fracture and bone parameters, controlling for maturity, body mass, leg length, ethnicity, and physical activity. Associations between prior fracture and all DXA and pQCT bone parameters at diaphyseal sites were nonsignificant. In contrast, lower trabecular volumetric BMD (vBMD) at distal metaphyseal sites of the femur and tibia was significantly associated with prior fracture. After adjustment for covariates, every SD decrease in trabecular vBMD at metaphyseal sites of the distal femur and tibia was associated with 1.4 (1.1–1.9) and 1.3 (1.0–1.7) times higher fracture prevalence, respectively. Prior fracture was not associated with metaphyseal bone size (ie, periosteal circumference). In conclusion, fractures in girls are associated with lower trabecular vBMD, but not bone size, at metaphyseal sites of the femur and tibia. Lower trabecular vBMD at metaphyseal sites of long bones may be an early marker of skeletal fragility in girls. © 2011 American Society for Bone and Mineral Research. PMID:20721933

  1. Lower trabecular volumetric BMD at metaphyseal regions of weight-bearing bones is associated with prior fracture in young girls.

    PubMed

    Farr, Joshua N; Tomás, Rita; Chen, Zhao; Lisse, Jeffrey R; Lohman, Timothy G; Going, Scott B

    2011-02-01

    Understanding the etiology of skeletal fragility during growth is critical for the development of treatments and prevention strategies aimed at reducing the burden of childhood fractures. Thus we evaluated the relationship between prior fracture and bone parameters in young girls. Data from 465 girls aged 8 to 13 years from the Jump-In: Building Better Bones study were analyzed. Bone parameters were assessed at metaphyseal and diaphyseal sites of the nondominant femur and tibia using peripheral quantitative computed tomography (pQCT). Dual-energy X-ray absorptiometry (DXA) was used to assess femur, tibia, lumbar spine, and total body less head bone mineral content. Binary logistic regression was used to evaluate the relationship between prior fracture and bone parameters, controlling for maturity, body mass, leg length, ethnicity, and physical activity. Associations between prior fracture and all DXA and pQCT bone parameters at diaphyseal sites were nonsignificant. In contrast, lower trabecular volumetric BMD (vBMD) at distal metaphyseal sites of the femur and tibia was significantly associated with prior fracture. After adjustment for covariates, every SD decrease in trabecular vBMD at metaphyseal sites of the distal femur and tibia was associated with 1.4 (1.1-1.9) and 1.3 (1.0-1.7) times higher fracture prevalence, respectively. Prior fracture was not associated with metaphyseal bone size (ie, periosteal circumference). In conclusion, fractures in girls are associated with lower trabecular vBMD, but not bone size, at metaphyseal sites of the femur and tibia. Lower trabecular vBMD at metaphyseal sites of long bones may be an early marker of skeletal fragility in girls. Copyright © 2011 American Society for Bone and Mineral Research.

  2. [The rotationally stable screw-anchor with trochanteric stabilizing plate (RoSA/TSP) : First results in unstable trochanteric femur fractures].

    PubMed

    Maier, K-J; Bücking, B; Horst, K; Andruszkow, H; Hildebrand, F; Knobe, M

    2017-12-01

    In unstable trochanteric fractures, the extramedullary rotationally stable screw-anchor (RoSA) combines the benefits of the load and rotational stability of the blade with the advantages of the screw (pull-out resistance, compression capability) in a single load carrier, and was designed to prevent femoral neck shortening by using an additional locked trochanteric stabilizing plate (TSP). The aim of the current prospective cohort study was the clinical evaluation of the RoSA/TSP system regarding the mechanical re-operation rate and the amount of postoperative femoral neck shortening. From September 2011 to January 2014 80 patients with unstable trochanteric fractures underwent internal extramedullary fixation with the RoSA/TSP (Königsee Implantate GmbH, Allendorf, Germany). Due to fracture stability and after induction of compression, additional long locked antitelescoping screws (AT, n = 1-4) were placed reaching the femoral head. Radiological (femoral neck shortening) and clinical re-examination of patients (n = 61) was performed 6-10 weeks and 6-10 months later. In the 61 re-examined patients (76 %) femoral neck shortening was very low with 2 mm 6-10 months after operation. Re-operations occurred in 8 % (n = 6) and in 4 % (n = 3) as prophylactic surgical intervention. Whereas one-third (4 %) of re-operations occurred due to iatrogenic surgical problems from the first operation two-thirds of patients (8 %) had a re-operation due to delay of bone union (3× nonunion, 3 planned removals of AT-screws to improve healing). The in-hospital mortality was 3 % (n = 2). The fixation of unstable trochanteric femur fractures using the RoSA/TSP in a first clinical setting led to a great primary stability, with significant advantages with regard to limited femoral neck shortening. However, the rigidity of the construct with its consequences regarding bone healing can be challenging for the surgeon. Nevertheless, in some cases of revision it could be beneficial

  3. Bilateral avascular necrosis of the femoral head following asynchronous postictal femoral neck fractures: a case report and review of the literature.

    PubMed

    Venkatadass, K; Avinash, M; Rajasekaran, S

    2018-05-01

    Bilateral avascular necrosis (AVN) following postictal bilateral fracture neck of the femur is a rare occurrence. Here, we report a case of bilateral AVN of the femoral head following an asynchronous bilateral postictal fracture neck of the femur. A 16-year-old autistic boy presented with left hip pain following an episode of seizures and radiographs showed Delbet type II fracture neck of the left femur. This was treated by closed reduction and cancellous screw fixation and skeletal traction for 6 weeks. At 3 months, follow-up radiograph showed union of the fracture, but he had developed segmental AVN with collapse of the head. At 8 months, the patient presented with pain in the right hip following another episode of seizures and radiograph of the pelvis showed a fresh Delbet type II fracture neck of the right femur with established AVN of the left femoral head. He underwent closed reduction and cancellous screw fixation of the right hip and implant exit of the left hip. At the 6-month follow-up after this surgery, his radiograph of the pelvis showed AVN with collapse and extrusion of the femoral head on the right side as well. Literature review shows an increased risk of fracture neck of the femur among epileptics. The incidence of AVN is maximum in Delbet type I, followed by Delbet type II and type III in that order. Although there are no clear guidelines on the management of post-traumatic AVN of the femoral head, the majority have reported that most of them will eventually develop arthritis and will require total hip replacement at a later date. Upon extensive literature search, no case report of bilateral fracture neck of the femur with bilateral AVN was found and hence this case was reported.

  4. Isolated, extra-articular neck and shaft fractures of the 4th and 5th metacarpals: a comparison of transverse and bouquet (intra-medullary) pinning in 67 patients.

    PubMed

    Sletten, I N; Nordsletten, L; Husby, T; Ødegaard, R A; Hellund, J C; Kvernmo, H D

    2012-06-01

    Although extra-articular metacarpal fractures are common, there is no consensus on the mode of treatment. We evaluated the outcome in 67 patients operated for isolated, extra-articular fractures in the neck or shaft of the ulnar two metacarpals 28 months post-operatively. There were 22 bouquet (intra-medullary) pinnings and 45 transverse pinnings; 11 were lost to follow-up. Overall, hand function was good, and no difference was detected between the two methods (QuickDASH, grip strength, range of motion, VAS pain and VAS satisfaction). Many patients suffered complications: 12% had a superficial infection (all treated with transverse pinning with wires left exposed); 39% had some impairment in skin sensation; 29% reported cold intolerance; and 10% had other complications. Due to the potential risk of a secondary fracture of the neighbouring metacarpal after transverse pinning, we recommend bouquet (intra-medullary) pinning. We also recommend burying wires beneath the skin surface to avoid infection.

  5. Treatment dilemma in multiple metatarsal fractures: when to operate?

    PubMed

    Mahan, Susan T; Lierhaus, Anneliese M; Spencer, Samantha A; Kasser, James R

    2016-07-01

    Fractures of multiple metatarsals in the pediatric population are uncommon; however, indications for surgical treatment have not been delineated. The aim of this study was to review multiple metatarsal fractures to help refine surgical indications. A total of 98 patients had multiple metatarsal fractures; displacement greater than 10% shaft width (displaced) was encountered in 33 (34.0%) patients. Fifteen patients had displacement of more than 75% shaft width of one metatarsal. Patients older than 14 years of age were more likely to have surgery for their injury (52.6%) than those younger than 14 years of age (3.7%) (P<0.0001). Younger patients and those with less than 75% displacement should be considered for nonoperative care. Level IV.

  6. Semiextended approach for intramedullary nailing via a patellar eversion technique for tibial-shaft fractures: Evaluation of the patellofemoral joint.

    PubMed

    Yasuda, Tomohiro; Obara, Shu; Hayashi, Junji; Arai, Masayuki; Sato, Kaoru

    2017-06-01

    Intramedullary nail fixation is a common treatment for tibial-shaft fractures, and it offers a better functional prognosis than other conservative treatments. Currently, the primary approach employed during intramedullary nail insertion is the semiextended position is the suprapatellar approach, which involves a vertical incision of the quadriceps tendon Damage to the patellofemoral joint cartilage has been highlighted as a drawback associated with this approach. To avoid this issue, we perform surgery using the patellar eversion technique and a soft sleeve. This method allows the articular surface to be monitored during intramedullary nail insertion. We arthroscopically assessed the effect of this technique on patellofemoral joint cartilage. The patellar eversion technique allows a direct view and protection of the patellofemoral joint without affecting the patella. Thus, damage to the patellofemoral joint cartilage can be avoided. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Real frequency of ordinary and atypical sub-trochanteric and diaphyseal fractures in France based on X-rays and medical file analysis.

    PubMed

    Beaudouin-Bazire, Constance; Dalmas, Noémie; Bourgeois, Julie; Babinet, Antoine; Anract, Philippe; Chantelot, Christophe; Farizon, Frédéric; Chopin, Florence; Briot, Karine; Roux, Christian; Cortet, Bernard; Thomas, Thierry

    2013-03-01

    Atypical sub-trochanteric and femoral shaft fractures have been reported in patients treated with bisphosphonates. Their incidence has been determined from registered data analysis using international codes. Therefore, the aim of our study was to estimate the real frequency of typical and atypical sub-trochanteric or diaphyseal fractures, based on radiological and clinical data compared to registered data. In the registers of three large French University Hospitals, patients identified with International Classification of Diseases, 10th Revision diagnosis codes for sub-trochanteric or diaphyseal fracture were selected. Frequencies of ordinary and atypical fractures were calculated after both registered data, radiological and clinical files analysis. Among the 4592 patients hospitalized for a femoral fracture over 5 years, 574 were identified to have had a sub-trochanteric or femoral shaft fracture. 47.7% of the sub-trochanteric and femoral shaft fractures were misclassified, predominantly in the sub-trochanteric fractures subset. 12 patients had an atypical fracture (4% of the sub-trochanteric and femoral shaft fractures) and 11 fractures presented radiological features of atypical fractures, whereas clinical files analysis revealed they were pathological or traumatic fractures. Atypical fractures frequency is very low. Because of their low frequency and the unreliability of registered databases, the risk of atypical fractures is very difficult to estimate retrospectively. A prospective study is needed to clarify the risk factors associated with these fractures. Copyright © 2012 Société française de rhumatologie. Published by Elsevier SAS. All rights reserved.

  8. Radiographic Investigation of the Distal Extension of Fractures Into the Articular Surface of the Tibia (The RIDEFAST Study).

    PubMed

    Marchand, Lucas S; Rane, Ajinkya A; Working, Zachary M; Jacobson, Lance G; Kubiak, Erik N; Higgins, Thomas F; Rothberg, David L

    2017-12-01

    To determine whether radiographic measurements are predictive of involvement of the distal tibia articular surface in tibial shaft fractures. Retrospective review. Academic Level-I trauma hospital. Two-hundred seventeen patients with tibial shaft fractures distal to the isthmus (OTA/AO: 42-A1-3; 42-B1-3; 42-C1-3; and 43-A1-3). Analysis of anteroposterior (AP) and lateral radiographs. The following parameters were measured: (1) angle between the predominant fracture line and the plane of the tibial plafond (α-angle), (2) length of the shaft fracture, (3) distance from the most inferior extent of the shaft fracture to the tibial plafond (DTP), (4) width of the tibial plafond, (5) width of the tibial isthmus, (6) ratio of fracture length to DTP (FTP), and (7) fibular fracture distance. Distal intra-articular involvement (DIA). A total of 217 patients were identified, 56 (26%) with DIA. The FTP ratio as measured on both the AP (odds ratio: 8.20, confidence interval, 4.26-17.22, P < 0.0001) and lateral radiographs (10.00, 4.78-23.23, <0.0001) was the most effective screening measurement for DIA. AP and lateral FTP ratios of 0.224 and 0.255, respectively, achieved a negative predictive value of 100%, eliminating the need for computed tomography in 16%-23% of injuries. Involvement of the distal articular surface in patients with distal tibial shaft fractures is significantly associated with fracture geometry and pattern. The FTP ratio may be used as an effective screening tool to rule out of intra-articular involvement. Diagnostic Level III. See Instructions for Authors for a complete description of levels of evidence.

  9. Insights into the effects of tensile and compressive loadings on human femur bone.

    PubMed

    Havaldar, Raviraj; Pilli, S C; Putti, B B

    2014-01-01

    Fragile fractures are most likely manifestations of fatigue damage that develop under repetitive loading conditions. Numerous microcracks disperse throughout the bone with the tensile and compressive loads. In this study, tensile and compressive load tests are performed on specimens of both the genders within 19 to 83 years of age and the failure strength is estimated. Fifty five human femur cortical samples are tested. They are divided into various age groups ranging from 19-83 years. Mechanical tests are performed on an Instron 3366 universal testing machine, according to American Society for Testing and Materials International (ASTM) standards. The results show that stress induced in the bone tissue depends on age and gender. It is observed that both tensile and compression strengths reduces as age advances. Compressive strength is more than tensile strength in both the genders. The compression and tensile strength of human femur cortical bone is estimated for both male and female subjecting in the age group of 19-83 years. The fracture toughness increases till 35 years in male and 30 years in female and reduces there after. Mechanical properties of bone are age and gender dependent.

  10. Assessment of risk of femoral neck fracture with radiographic texture parameters: a retrospective study.

    PubMed

    Thevenot, Jérôme; Hirvasniemi, Jukka; Pulkkinen, Pasi; Määttä, Mikko; Korpelainen, Raija; Saarakkala, Simo; Jämsä, Timo

    2014-07-01

    To investigate whether femoral neck fracture can be predicted retrospectively on the basis of clinical radiographs by using the combined analysis of bone geometry, textural analysis of trabecular bone, and bone mineral density (BMD). Formal ethics committee approval was obtained for the study, and all participants gave informed written consent. Pelvic radiographs and proximal femur BMD measurements were obtained in 53 women aged 79-82 years in 2006. By 2012, 10 of these patients had experienced a low-impact femoral neck fracture. A Laplacian-based semiautomatic custom algorithm was applied to the radiographs to calculate the texture parameters along the trabecular fibers in the lower neck area for all subjects. Intra- and interobserver reproducibility was calculated by using the root mean square average coefficient of variation to evaluate the robustness of the method. The best predictors of hip fracture were entropy (P = .007; reproducibility coefficient of variation < 1%), the neck-shaft angle (NSA) (P = .017), and the BMD (P = .13). For prediction of fracture, the area under the receiver operating characteristic curve was 0.753 for entropy, 0.608 for femoral neck BMD, and 0.698 for NSA. The area increased to 0.816 when entropy and NSA were combined and to 0.902 when entropy, NSA, and BMD were combined. Textural analysis of pelvic radiographs enables discrimination of patients at risk for femoral neck fracture, and our results show the potential of this conventional imaging method to yield better prediction than that achieved with dual-energy x-ray absorptiometry-based BMD. The combination of the entropy parameter with NSA and BMD can further enhance predictive accuracy. © RSNA, 2014.

  11. Diaphyseal long bone nonunions - types, aetiology, economics, and treatment recommendations.

    PubMed

    Rupp, Markus; Biehl, Christoph; Budak, Matthäus; Thormann, Ulrich; Heiss, Christian; Alt, Volker

    2018-02-01

    The intention of the current article is to review the epidemiology with related socioeconomic costs, pathophysiology, and treatment options for diaphyseal long bone delayed unions and nonunions. Diaphyseal nonunions in the tibia and in the femur are estimated to occur 4.6-8% after modern intramedullary nailing of closed fractures with an even much higher risk in open fractures. There is a high socioeconomic burden for long bone nonunions mainly driven by indirect costs, such as productivity losses due to long treatment duration. The classic classification of Weber and Cech of the 1970s is based on the underlying biological aspect of the nonunion differentiating between "vital" (hypertrophic) and "avital" (hypo-/atrophic) nonunions, and can still be considered to represent the basis for basic evaluation of nonunions. The "diamond concept" units biomechanical and biological aspects and provides the pre-requisites for successful bone healing in nonunions. For humeral diaphyseal shaft nonunions, excellent results for augmentation plating were reported. In atrophic humeral shaft nonunions, compression plating with stimulation of bone healing by bone grafting or BMPs seem to be the best option. For femoral and tibial diaphyseal shaft fractures, dynamization of the nail is an atraumatic, effective, and cheap surgical possibility to achieve bony consolidation, particularly in delayed nonunions before 24 weeks after initial surgery. In established hypertrophic nonunions in the tibia and femur, biomechanical stability should be addressed by augmentation plating or exchange nailing. Hypotrophic or atrophic nonunions require additional biological stimulation of bone healing for augmentation plating.

  12. Shaft/shaft-seal interface characteristics of a multiple disk centrifugal blood pump.

    PubMed

    Manning, K B; Miller, G E

    1999-06-01

    A multiple disk centrifugal pump (MDCP) is under investigation as a potential left ventricular assist device. As is the case with most shaft driven pumps, leakage problems around the shaft/shaft seal interface are of major interest. If leakage were to occur during or after implantation, potential events such as blood loss, clotting, blood damage, and/or infections might result in adverse effects for the patient. Because these effects could be quite disastrous, potential shaft and shaft seal materials have been investigated to determine the most appropriate course to limit these effects. Teflon and nylon shaft seals were analyzed as potential candidates along with a stainless steel shaft and a Melonite coated shaft. The materials and shafts were evaluated under various time durations (15, 30, 45, and 60 min), motor speeds (800, 1,000, 1,200, and 1,400 rpm), and outer diameters (1/2 and 3/4 inches). The motor speed and geometrical configurations were typical for the MDCP under normal physiologic conditions. An air and water study was conducted to analyze the inner diameter wear, the inner temperature values, and the outer temperature values. Statistical comparisons were computed for the shaft seal materials, the shafts, and the outer diameters along with the inner and outer temperatures. The conclusions made from the results indicate that both the tested shaft seal materials and shaft materials are not ideal candidates to be used for the MDCP. Teflon experienced a significant amount of wear in air and water studies. Nylon did experience little wear, but heat generation was an evident problem. A water study on nylon was not conducted because of its molecular structure.

  13. Evaluation for Occult Fractures in Injured Children

    PubMed Central

    French, Benjamin; Song, Lihai; Feudtner, Chris

    2015-01-01

    OBJECTIVES: To examine variation across US hospitals in evaluation for occult fractures in (1) children <2 years old diagnosed with physical abuse and (2) infants <1 year old with injuries associated with a high likelihood of abuse and to identify factors associated with such variation. METHODS: We performed a retrospective study in children <2 years old with a diagnosis of physical abuse and in infants <1 year old with non-motor vehicle crash–related traumatic brain injury or femur fractures discharged from 366 hospitals in the Premier database from 2009 to 2013. We examined across-hospital variation and identified child- and hospital-level factors associated with evaluation for occult fractures. RESULTS: Evaluations for occult fractures were performed in 48% of the 2502 children with an abuse diagnosis, in 51% of the 1574 infants with traumatic brain injury, and in 53% of the 859 infants with femur fractures. Hospitals varied substantially with regard to their rates of evaluation for occult fractures in all 3 groups. Occult fracture evaluations were more likely to be performed at teaching hospitals than at nonteaching hospitals (all P < .001). The hospital-level annual volume of young, injured children was associated with the probability of occult fracture evaluation, such that hospitals treating more young, injured patients were more likely to evaluate for occult fractures (all P < .001). CONCLUSIONS: Substantial variation in evaluation for occult fractures among young children with a diagnosis of abuse or injuries associated with a high likelihood of abuse highlights opportunities for quality improvement in this vulnerable population. PMID:26169425

  14. Evaluation for Occult Fractures in Injured Children.

    PubMed

    Wood, Joanne N; French, Benjamin; Song, Lihai; Feudtner, Chris

    2015-08-01

    To examine variation across US hospitals in evaluation for occult fractures in (1) children <2 years old diagnosed with physical abuse and (2) infants <1 year old with injuries associated with a high likelihood of abuse and to identify factors associated with such variation. We performed a retrospective study in children <2 years old with a diagnosis of physical abuse and in infants <1 year old with non-motor vehicle crash-related traumatic brain injury or femur fractures discharged from 366 hospitals in the Premier database from 2009 to 2013. We examined across-hospital variation and identified child- and hospital-level factors associated with evaluation for occult fractures. Evaluations for occult fractures were performed in 48% of the 2502 children with an abuse diagnosis, in 51% of the 1574 infants with traumatic brain injury, and in 53% of the 859 infants with femur fractures. Hospitals varied substantially with regard to their rates of evaluation for occult fractures in all 3 groups. Occult fracture evaluations were more likely to be performed at teaching hospitals than at nonteaching hospitals (all P < .001). The hospital-level annual volume of young, injured children was associated with the probability of occult fracture evaluation, such that hospitals treating more young, injured patients were more likely to evaluate for occult fractures (all P < .001). Substantial variation in evaluation for occult fractures among young children with a diagnosis of abuse or injuries associated with a high likelihood of abuse highlights opportunities for quality improvement in this vulnerable population. Copyright © 2015 by the American Academy of Pediatrics.

  15. Shaft balancing

    DOEpatents

    Irwin, John A.

    1979-01-01

    A gas turbine engine has an internal drive shaft including one end connected to a driven load and an opposite end connected to a turbine wheel and wherein the shaft has an in situ adjustable balance system near the critical center of a bearing span for the shaft including two 360.degree. rings piloted on the outer diameter of the shaft at a point accessible through an internal engine panel; each of the rings has a small amount of material removed from its periphery whereby both of the rings are precisely unbalanced an equivalent amount; the rings are locked circumferentially together by radial serrations thereon; numbered tangs on the outside diameter of each ring identify the circumferential location of unbalance once the rings are locked together; an aft ring of the pair of rings has a spline on its inside diameter that mates with a like spline on the shaft to lock the entire assembly together.

  16. Reconstruction of juxta-articular huge defects of distal femur with vascularized fibular bone graft and Ilizarov's distraction osteogenesis.

    PubMed

    Lai, Davy; Chen, Chuan-Mu; Chiu, Fang-Yao; Chang, Ming-Chau; Chen, Tain-Hsiung

    2007-01-01

    We evaluate the effect of reconstructing huge defects (mean, 15.8 cm) of the distal femur with Ilizarov's distraction osteogenesis and free twin-barreled vascularized fibular bone graft (TVFG). We retrospectively reviewed a consecutive series of five patients who had cases of distal femoral fractures with huge defects and infection that were treated by the Ilizarov's distraction osteogenesis. After radical debridement, two of the five cases had free TVFG and monolocal distraction osteogenesis, and another two cases had multilocal distraction osteogenesis with knee fusion because of loss of the joint congruity. The other case with floating knee injury had bilocal distraction osteogenesis and a preserved knee joint. The mean defect of distal femur was 15.8 cm (range, 14-18 cm) in length. The mean length of distraction osteogenesis by Ilizarov's apparatus was 8.2 cm. The mean length of TVFG was 8 cm. The average duration from application of Ilizarov's apparatus to achievement of bony union was 10.2 months (range, 8-13 months). At the end of the follow-up, ranges of motion of three knees were 0 to 45 degrees, 0 to 60 degrees, and 0 to 90 degrees. Two cases had knee arthrodesis with bony fusion because of loss of the joint congruity. There were no leg length discrepancies in all five patients. In addition, three patients had pin tract infections and one case had a 10 degree varus deformity of the femur. Juxta-articular huge defect (>10 cm) of distal femur remains a challenge to orthopedic surgeons. Ilizarov's technique provides the capability to maintain stability, eradicate infection, restore leg length, and to perform adjuvant reconstructive procedure easily. In this study, we found that combining Ilizarov's distraction osteogenesis with TVFG results in improved patient outcome for patients with injuries such as supracondylar or intercondylar infected fractures or nonunion of distal femur with huge bone defect.

  17. Detection of cracks in shafts with the Approximated Entropy algorithm

    NASA Astrophysics Data System (ADS)

    Sampaio, Diego Luchesi; Nicoletti, Rodrigo

    2016-05-01

    The Approximate Entropy is a statistical calculus used primarily in the fields of Medicine, Biology, and Telecommunication for classifying and identifying complex signal data. In this work, an Approximate Entropy algorithm is used to detect cracks in a rotating shaft. The signals of the cracked shaft are obtained from numerical simulations of a de Laval rotor with breathing cracks modelled by the Fracture Mechanics. In this case, one analysed the vertical displacements of the rotor during run-up transients. The results show the feasibility of detecting cracks from 5% depth, irrespective of the unbalance of the rotating system and crack orientation in the shaft. The results also show that the algorithm can differentiate the occurrence of crack only, misalignment only, and crack + misalignment in the system. However, the algorithm is sensitive to intrinsic parameters p (number of data points in a sample vector) and f (fraction of the standard deviation that defines the minimum distance between two sample vectors), and good results are only obtained by appropriately choosing their values according to the sampling rate of the signal.

  18. Finite element analysis of a bone healing model: 1-year follow-up after internal fixation surgery for femoral fracture.

    PubMed

    Jiang-Jun, Zhou; Min, Zhao; Ya-Bo, Yan; Wei, Lei; Ren-Fa, Lv; Zhi-Yu, Zhu; Rong-Jian, Chen; Wei-Tao, Yu; Cheng-Fei, Du

    2014-03-01

    Finite element analysis was used to compare preoperative and postoperative stress distribution of a bone healing model of femur fracture, to identify whether broken ends of fractured bone would break or not after fixation dislodgement one year after intramedullary nailing. Method s: Using fast, personalized imaging, bone healing models of femur fracture were constructed based on data from multi-slice spiral computed tomography using Mimics, Geomagic Studio, and Abaqus software packages. The intramedullary pin was removed by Boolean operations before fixation was dislodged. Loads were applied on each model to simulate a person standing on one leg. The von Mises stress distribution, maximum stress, and its location was observed. Results : According to 10 kinds of display groups based on material assignment, the nodes of maximum and minimum von Mises stress were the same before and after dislodgement, and all nodes of maximum von Mises stress were outside the fracture line. The maximum von Mises stress node was situated at the bottom quarter of the femur. The von Mises stress distribution was identical before and after surgery. Conclusion : Fast, personalized model establishment can simulate fixation dislodgement before operation, and personalized finite element analysis was performed to successfully predict whether nail dislodgement would disrupt femur fracture or not.

  19. Online shaft encoder geometry compensation for arbitrary shaft speed profiles using Bayesian regression

    NASA Astrophysics Data System (ADS)

    Diamond, D. H.; Heyns, P. S.; Oberholster, A. J.

    2016-12-01

    The measurement of instantaneous angular speed is being increasingly investigated for its use in a wide range of condition monitoring and prognostic applications. Central to many measurement techniques are incremental shaft encoders recording the arrival times of shaft angular increments. The conventional approach to processing these signals assumes that the angular increments are equidistant. This assumption is generally incorrect when working with toothed wheels and especially zebra tape encoders and has been shown to introduce errors in the estimated shaft speed. There are some proposed methods in the literature that aim to compensate for this geometric irregularity. Some of the methods require the shaft speed to be perfectly constant for calibration, something rarely achieved in practice. Other methods assume the shaft speed to be nearly constant with minor deviations. Therefore existing methods cannot calibrate the entire shaft encoder geometry for arbitrary shaft speeds. The present article presents a method to calculate the shaft encoder geometry for arbitrary shaft speed profiles. The method uses Bayesian linear regression to calculate the encoder increment distances. The method is derived and then tested against simulated and laboratory experiments. The results indicate that the proposed method is capable of accurately determining the shaft encoder geometry for any shaft speed profile.

  20. Navigation system for robot-assisted intra-articular lower-limb fracture surgery.

    PubMed

    Dagnino, Giulio; Georgilas, Ioannis; Köhler, Paul; Morad, Samir; Atkins, Roger; Dogramadzi, Sanja

    2016-10-01

    In the surgical treatment for lower-leg intra-articular fractures, the fragments have to be positioned and aligned to reconstruct the fractured bone as precisely as possible, to allow the joint to function correctly again. Standard procedures use 2D radiographs to estimate the desired reduction position of bone fragments. However, optimal correction in a 3D space requires 3D imaging. This paper introduces a new navigation system that uses pre-operative planning based on 3D CT data and intra-operative 3D guidance to virtually reduce lower-limb intra-articular fractures. Physical reduction in the fractures is then performed by our robotic system based on the virtual reduction. 3D models of bone fragments are segmented from CT scan. Fragments are pre-operatively visualized on the screen and virtually manipulated by the surgeon through a dedicated GUI to achieve the virtual reduction in the fracture. Intra-operatively, the actual position of the bone fragments is provided by an optical tracker enabling real-time 3D guidance. The motion commands for the robot connected to the bone fragment are generated, and the fracture physically reduced based on the surgeon's virtual reduction. To test the system, four femur models were fractured to obtain four different distal femur fracture types. Each one of them was subsequently reduced 20 times by a surgeon using our system. The navigation system allowed an orthopaedic surgeon to virtually reduce the fracture with a maximum residual positioning error of [Formula: see text] (translational) and [Formula: see text] (rotational). Correspondent physical reductions resulted in an accuracy of 1.03 ± 0.2 mm and [Formula: see text], when the robot reduced the fracture. Experimental outcome demonstrates the accuracy and effectiveness of the proposed navigation system, presenting a fracture reduction accuracy of about 1 mm and [Formula: see text], and meeting the clinical requirements for distal femur fracture reduction procedures.

  1. Factors related to curved femur in elderly Japanese women

    PubMed Central

    Tsuchie, Hiroyuki; Miyakoshi, Naohisa; Kasukawa, Yuji; Senma, Seietsu; Narita, Yuichiro; Miyamoto, Seiya; Hatakeyama, Yuji; Sasaki, Kana; Shimada, Yoichi

    2016-01-01

    Background Multiple factors are involved in the development of atypical femoral fractures, and excessive curvature of the femur is thought to be one of them. However, the pathogenesis of femoral curvature is unknown. We evaluated the influence of factors related to bone metabolism and posture on the development of femoral curvature. Methods A total of 139 women participated in the present study. Curvatures were measured using antero-posterior and lateral radiography of the femur. We evaluated some bone and vitamin D metabolism markers in serum, the bone mineral density (BMD), lumbar spine alignment, and pelvic tilt. Results We divided the women into two groups, curved and non-curved groups, based on the average plus standard deviation as the cut-off between the groups. When univariate logistic regression analysis was performed to detect factors affecting femoral curvature, the following were identified as indices significantly affecting the curvature: age of the patients, serum concentrations of calcium, intact parathyroid hormone, pentosidine, homocysteine and 25-hydroxyvitamin D (25(OH)D), and BMD of the proximal femur (P < 0.05) both in the lateral and anterior curvatures. When we used multivariate analyses to assess these factors, only 25(OH)D and age (lateral and anterior standardized odds ratio: 0.776 and 0.385, and 2.312 and 4.472, respectively) affected the femoral curvature (P < 0.05). Conclusion Femoral curvature is strongly influenced by age and serum vitamin D. PMID:27228191

  2. Hormone Therapy Improves Femur Geometry Among Ethnically Diverse Postmenopausal Participants in the Women's Health Initiative Hormone Intervention Trials

    PubMed Central

    Chen, Zhao; Beck, Thomas J; Cauley, Jane A; Lewis, Cora E; LaCroix, Andrea; Bassford, Tamsen; Wu, Guanglin; Sherrill, Duane; Going, Scott

    2008-01-01

    Loss of bone strength underlies osteoporotic fragility fractures. We hypothesized that hormone interventions significantly improve the structural geometry of proximal femur cross-sections. Study participants were from the Women's Health Initiative hormone intervention trials: either the conjugated equine estrogen (CEE) only (N placebo = 447, N CEE = 422) trial or the estrogen (E) plus progestin (P) (N placebo = 441, N E+P = 503) trial, who were 50–79 yr old at baseline and were followed up to 6 yr. BMD scans by DXA were conducted at baseline, year 1, year 3, and year 6. Femur geometry was derived from hip DXA scans using the hip structural analysis (HSA) method. Mixed effects models with the intent-to-treat analysis approach were used. There were no significant differences in treatment effects between the E-alone and the E + P trial, so the analyses were conducted with participants combined from both trials. Treatment benefits (p < 0.05) on femur geometry were observed as early as 1 yr after the intervention. From baseline to year 6, section modulus (a measure of maximum bending stress) was preserved, and buckling ratio (an index of cortical instability under compression) was reduced by hormone interventions (p < 0.05); the differences in the percent changes from baseline to year 6 between women on hormone intervention versus women on placebo were 2.3–3.6% for section modulus and –5.3% to – 4.3% for buckling ratio. Hormone interventions led to favorable changes in femur geometry, which may help explain the reduced fracture risk observed in hormone interventions. PMID:18665788

  3. Is arthroplasty preferable to internal fixation for the treatment of extracapsular fracture of the upper femur in the elderly?

    PubMed

    Duriez, P; Devaux, T; Chantelot, C; Baudrier, N; Hery, J-Y; Mainard, D; Favier, T; Massin, P

    2016-10-01

    Although internal fixation is the reference treatment for extracapsular fracture of the upper femur, indications for arthroplasty are broadening, especially in unstable comminutive fracture in fragile bone. The present study hypothesis was that arthroplasty reduces early mortality and morbidity and provides better recovery of autonomy in over-80 year-old patients than does internal fixation. A prospective multicenter study was conducted on 8 sites. Internal fixation was systematically used in 5 centers; arthroplasty was used systematically in 1 center, and reserved for unstable fracture in 2 centers. A total of 697 patients aged over 80 years (mean age, 85±5 years), presenting with extracapsular fracture, were included; 521 were treated by internal fixation and 176 by arthroplasty. Results were studied on multivariate analysis of ASA score, blood loss, transfusion, and also of treatment modality as an independent factor for early (first 6 months) mortality and morbidity (mechanical, general and nutritional complications) and functional outcome (autonomy and dependence). Overall mortality was 19.2%. Autonomy deteriorated in 56% of patients alive at 6 months and dependence worsened in 44%. Two percent of those managed by internal fixation underwent revision for disassembly (n=8) or infection (n=1). Eight percent of those managed by arthroplasty underwent revision for dislocation (n=4), implant loosening (n=3) or infection (n=7). On univariate analysis, mortality was higher in the arthroplasty group (25%) than with internal fixation (17%; P=0.002), as were blood loss (425±286mL versus 333±223mL; P<0.0001), transfusion rate (61% versus 32%; P<0.0001) and infection (4% versus 0.2%; P<0.001). On multivariate analysis, however, treatment modality no longer showed impact on mortality or on morbidity and autonomy at 6 months. Nutritional status was better conserved at 6 months following arthroplasty, but dependence worsened. Poor preoperative autonomy, ASA score, and

  4. Fully automatic segmentation of the femur from 3D-CT images using primitive shape recognition and statistical shape models.

    PubMed

    Ben Younes, Lassad; Nakajima, Yoshikazu; Saito, Toki

    2014-03-01

    Femur segmentation is well established and widely used in computer-assisted orthopedic surgery. However, most of the robust segmentation methods such as statistical shape models (SSM) require human intervention to provide an initial position for the SSM. In this paper, we propose to overcome this problem and provide a fully automatic femur segmentation method for CT images based on primitive shape recognition and SSM. Femur segmentation in CT scans was performed using primitive shape recognition based on a robust algorithm such as the Hough transform and RANdom SAmple Consensus. The proposed method is divided into 3 steps: (1) detection of the femoral head as sphere and the femoral shaft as cylinder in the SSM and the CT images, (2) rigid registration between primitives of SSM and CT image to initialize the SSM into the CT image, and (3) fitting of the SSM to the CT image edge using an affine transformation followed by a nonlinear fitting. The automated method provided good results even with a high number of outliers. The difference of segmentation error between the proposed automatic initialization method and a manual initialization method is less than 1 mm. The proposed method detects primitive shape position to initialize the SSM into the target image. Based on primitive shapes, this method overcomes the problem of inter-patient variability. Moreover, the results demonstrate that our method of primitive shape recognition can be used for 3D SSM initialization to achieve fully automatic segmentation of the femur.

  5. Interlocking Intramedullary Nailing Versus Locked Dual-Plating Fixation for Femoral Shaft Fractures in Patients with Multiple Injuries: A Retrospective Comparative Study.

    PubMed

    Cheng, Tao; Xia, Rong-Gang; Dong, Shi-Kui; Yan, Xiao-Yu; Luo, Cong-Feng

    2017-12-18

    Intramedullary nailing (IMN) is a popular method in the management of femoral shaft fractures (FSFs). However, whether the association of IMN with pulmonary fat emboli can compromise the pulmonary and nervous systems is debatable. The purpose of this study is to compare IMN with the locked dual plating (LDP) method by assessing the clinical outcomes of FSF patients with head or chest injury. A total of 126 FSF patients were included in this study between January 2010 and July 2016 and divided into LDP and IMN groups. Patient demographic characteristics, operative time, blood loss, Harris Hip Score, Lysholm Knee Score, radiological outcomes, and systemic complications were collected and compared between the two treatment groups. Patients were followed up for at least 12 months. The LDP group performed better than IMN in terms of operative time, estimated blood loss amount, and malunion rate. Differences in function scores, fracture union rate, overall pulmonary complication rate, and in-hospital mortality between the two groups were not significant. Average radiographic union time was significantly longer in the LDP group (36.3 weeks) than in the IMN group (32.5 weeks). One case of fixation failure occurred postoperatively in the LDP group, whereas one case of fracture nonunion took place in the IMN group. Our findings suggest that dual-plating fixation is a promising method for FSFs with multiple injuries. However, the retrospective nature of this study necessitates high-quality trials to be performed to assess the clinical efficiency of dual plating.

  6. Comparative investigation of percutaneous plating and intramedullary nailing effects on IL-6 production in patients with tibia shaft fracture.

    PubMed

    Ebrahimpour, Adel; Okhovatpour, Mohammad-Ali; Sadighi, Mehrdad; Sarejloo, Amir-Hossein; Sajjadi, Mohammad-Reza Minator

    2017-12-01

    The aim of this study was to analyze the effect of intramedullary nailing (IMN), open plating and percutaneous plating on the induction of IL-6 in patients with tibia fractures. A total of 30 patients with tibia shaft fracture underwent either intramedullary nailing (IMN, n = 15; 14 males and 1 female; mean age: 32.1 ± 15.6), ORIF plating (n = 8; 5 males and 3 females; mean age: 60.0 ± 17.8), or percutaneous plating (n = 7; 6 males and 1 female; mean age: 43.1 ± 21.4). Serum IL-6 cytokine levels were measured prior to, and 6 and 24 h after the surgery, using a special ELISA kit. The IL-6 concentration increased to peak levels at 6 h in both IMN and percutaneous plating groups, and at 24 h in ORIF plating group (p < 0.001). The mean IL-6 concentration of percutaneous plating group was significantly lower than that of the IMN group at 6 h following the surgery (p = 0.022). In addition, the mean IL-6 concentration of ORIF plating group was significantly higher than that of the percutaneous plating group at 24 h post operation (p = 0.009). Our results suggest that percutaneous plating compared to the IMN has lower effects on IL-6 production in patients with tibia fracture. Level III, therapeutic study. Copyright © 2017 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  7. Necrotizing fasciitis after internal fixation of fracture of femoral trochanteric☆☆☆

    PubMed Central

    Santos, Leandro Emílio Nascimento; Pires, Robinson Esteves Santos; Figueiredo, Leonardo Brandão; Soares, Eduardo Augusto Marques

    2014-01-01

    Necrotizing fasciitis is a rare and potentially lethal soft tissue infection. We report a case of trochanteric femur fracture in a patient who underwent fracture fixation and developed necrotizing fasciitis. A literature review on the topic will be addressed. PMID:26229777

  8. Transverse Stress Fracture of the Proximal Patella

    PubMed Central

    Atsumi, Satoru; Arai, Yuji; Kato, Ko; Nishimura, Akinobu; Nakazora, Shigeto; Nakagawa, Shuji; Ikoma, Kazuya; Fujiwara, Hiroyoshi; Sudo, Akihiro; Kubo, Toshikazu

    2016-01-01

    Abstract Among stress fractures associated with sports activities, patellar stress fracture is rare. Regarding patella stress fractures, so far only distal transverse or lateral longitudinal fractures have been reported, but there are no reports of transverse fractures occurring in the proximal patella. We describe an extremely rare case of transverse stress fracture of proximal patella in a 9-year-old athlete. A 9-year old boy, who participated in sports (sprints and Kendo) presented with left knee pain without any external injury. In plain radiographs, a fracture line was observed in the proximal 1/3 of the left patella, and a patella stress fracture was diagnosed. For treatment, because 7 months of conservative therapy showed no improvement, internal fixation was carried out using Acutrak screws, and bone union was thus achieved. Three months after the operation, he was able to return to his previous level of athletic sports activity. Regarding the mechanism of onset, it is believed that the causes are longitudinal traction force and patellofemoral contact pressure. On the other hand, the contact region of the patella with the femur changes with the flexion angle of the knee. In the current case, the fracture occurred at a site where the patella was in contact with the femur at a flexion angle of >90°, so it is believed that it occurred as a clinical condition from being subjected to repeated longitudinal traction force and patellofemoral contact pressure at a flexion angle of >90°, during the sports activities of sprints and Kendo. The nonunion of the transverse stress fracture of his proximal patella was successfully treated with internal fixation using Acutrak screws. PMID:26871789

  9. Removal of well-fixed components in femoral revision arthroplasty with controlled segmentation of the proximal femur.

    PubMed

    Megas, Panagiotis; Georgiou, Christos S; Panagopoulos, Andreas; Kouzelis, Antonis

    2014-12-31

    The transfemoral and the extended trochanteric osteotomies are the most common osteotomies used in femoral revision, both when proximal or diaphyseal fixation of the new component has been decided. We present an alternative approach to the trochanteric osteotomies, most frequently used with distally fixated stems, to overcome their shortcomings of osteotomy migration and nonunion, but, most of all, the uncontrollable fragmentation of the femur. The procedure includes a complete circular femoral osteotomy just below the stem tip to prevent distal fracture propagation and a subsequent preplanned segmentation of the proximal femur for better exposure and fast removal of the old prosthesis. The bone fragments are reattached with cerclage wires to the revision prosthesis, which is safely anchored distally. A modified posterolateral approach is used, as the preservation of the continuity of the abductors, the greater trochanter, and the vastus lateralis is a prerequisite. Between 2006 and 2012, 47 stems (33 women, 14 men, mean age 68 years, range 39-88 years) were revised using this technique. They were 12 (26%) stable and 35 (74%) loose prostheses and were all revised to tapered, fluted, grit-blasted stems. No fracture of the trochanters or the distal femur occurred intraoperatively. Mean follow-up was 28 months (range 6-70 months). No case of trochanteric migration or nonunion of the osteotomies was recorded. Restoration of the preexisting bone defects occurred in 83% of the patients. Three patients required repeat revision due to dislocation and one due to a postoperative periprosthetic fracture. None of the failures was attributed to the procedure itself. This new osteotomy technique may seem aggressive at first, but, at least in our hands, has effectively increased the speed of the femoral revision, particularly for the most difficult well-fixed components, but not at the expense of safety.

  10. Design of transmission shafting

    NASA Technical Reports Server (NTRS)

    Loewenthal, S. H.

    1978-01-01

    Formula considers flexure fatigue characteristics of shaft material under combined cyclic bending and static torsion stress. Formula permits selecting shaft sizes that meet common loading conditions without adding on excessive shaft material. Formula is applicable to design of rotary power or torque transmission shafting external to machine elements.

  11. [Simultaneous existence of unicameral bone cysts involving the femur and ischium].

    PubMed

    Makris, Vassilios; Papavasiliou, Kyriakos A; Bobos, Mattheos; Hytiroglou, Prodromos; Kirkos, John M; Kapetanos, George A

    2009-01-01

    We report a 30-year-old male patient with two unicameral bone cysts (UBC) simultaneously located in the proximal third of the right femur and ipsilateral ischium ramus, respectively. Fine needle biopsies were attempted for both lesions. Biopsy of the femoral lesion under local anesthesia was unsuccessful, so an open biopsy was performed which confirmed the diagnosis of UBC. Biopsy of the ischial lesion was not sufficient for diagnosis. Cytological examination of both specimens showed no other benign or malignant pathology. The femoral lesion was treated with intralesional (due to its large size) excision-curettage, bone grafting, and the introduction of a long gamma locking intramedullary nail to prevent the occurrence of a pathological fracture. The ischial lesion was left untreated and followed conservatively. The patient was free of any symptoms and complications three years postoperatively. This is the first report of an adult patient with UBCs simultaneously located both in a long tubular bone (femur) and a flat bone (ischium ramus).

  12. Should fractures in massive intercalary bone allografts of the lower limb be treated with ORIF or with a new allograft?

    PubMed

    Aponte-Tinao, Luis A; Ayerza, Miguel A; Muscolo, D Luis; Farfalli, Germán L

    2015-03-01

    Massive bone allografts have been used for limb salvage of bone tumor resections as an alternative to endoprostheses, although they have different outcomes and risks. There is no general consensus about when to use these alternatives, but when it is possible to save the native joints after the resection of a long bone tumor, intercalary allografts offer some advantages despite complications, such as fracture. The management and outcomes of this complication deserve more study. The purposes of this study were to (1) analyze the fracture frequency in a group of patients treated with massive intercalary bone allografts of the femur and tibia; (2) compare the results of allografts treated with open reduction and internal fixation (ORIF) with those treated with resection and repeat allograft reconstruction; and (3) determine the likelihood that treatment of a fracture resulted in a healed intercalary reconstruction. We reviewed patients treated with intercalary bone allografts between 1991 and 2011. During this period, patients were generally treated with intercalary allografts when after tumor resection at least 1 cm of residual epiphysis remained to allow fixation of the osteotomy junction. To obtain a homogeneous group of patients, we excluded allograft-prosthesis composites and osteoarticular and hemicylindrical intercalary allografts from this study. We analyzed the fracture rate of 135 patients reconstructed with segmental intercalary bone allografts of the lower extremities (98 femurs and 37 tibias). In patients whose grafts fractured were treated either by internal fixation or a second allograft, ORIF generally was attempted but after early failures in femur fractures, these fractures were treated with a second allograft. Using a chart review, we ascertained the frequency of osseous union, complications, and reoperations after the treatment of fractured intercalary allografts. Followup was at a mean of 101 months (range, 24-260 months); of the original 135

  13. Fracture of Fully-coated Femoral Stem after Primary Total Hip Arthroplasty for Nonunion of Intertrochanteric Fracture: A Case Report.

    PubMed

    Chun, Young Soo; Juh, Hyung Suk; Cho, Yoon Je; Rhyu, Kee Hyung

    2015-09-01

    Femoral stem fracture is an uncommon reason for the failure of total hip arthroplasty, with only 16 cases of fully coated stem fractures reported to date. Here we report a case in which a fully coated primary femoral stem fracture occurred after conversion to total hip arthroplasty for the non-union of an intertrochanteric fracture of the femur. Metallurgic evaluation of the etiology and mechanism revealed that the fracture was initiated by fatigue-related failure and completed by ductile failure on the posterior side of the fracture. Considering the recent trend of treating an intertrochanteric fracture with hip arthroplasty, possible stem failure should be considered, since most patients will have at least one of the known risk factors for stem fracture.

  14. Fracture of Fully-coated Femoral Stem after Primary Total Hip Arthroplasty for Nonunion of Intertrochanteric Fracture: A Case Report

    PubMed Central

    Chun, Young Soo; Juh, Hyung Suk; Cho, Yoon Je

    2015-01-01

    Femoral stem fracture is an uncommon reason for the failure of total hip arthroplasty, with only 16 cases of fully coated stem fractures reported to date. Here we report a case in which a fully coated primary femoral stem fracture occurred after conversion to total hip arthroplasty for the non-union of an intertrochanteric fracture of the femur. Metallurgic evaluation of the etiology and mechanism revealed that the fracture was initiated by fatigue-related failure and completed by ductile failure on the posterior side of the fracture. Considering the recent trend of treating an intertrochanteric fracture with hip arthroplasty, possible stem failure should be considered, since most patients will have at least one of the known risk factors for stem fracture. PMID:27536622

  15. Another fractured neck of femur: do we need a lateral X-ray?

    PubMed

    Almazedi, B; Smith, C D; Morgan, D; Thomas, G; Pereira, G

    2011-05-01

    This study aimed to define the role of the lateral X-ray in the assessment and treatment planning of proximal femoral fractures. Occult fractures were not included. Radiographs from 359 consecutive patients with proximal femoral fractures admitted to our emergency department over a 12 month period were divided into anteroposterior (AP) views and lateral views. Three blinded reviewers independently assessed the radiographs, first AP views alone then AP plus lateral views, noting the fracture classification for each radiograph. These assessments were then compared with the intra-operative diagnosis, which was used as the gold standard. A 2 × 2 contingency square table was created and Pearson's χ(2) test was used for statistical analysis. The rate of correct classification by the reviewers was improved by the assessment of the lateral X-ray in addition to the AP view for intracapsular fractures (p<0.013) but not for extracapsular fractures (p=0.27). However, the only advantage obtained by assessing the lateral view in intracapsular fractures was the detection of displacement where the fracture appeared undisplaced on the initial AP view. This study provides statistical evidence that one view is adequate and safe for the majority of hip fractures. The lateral radiograph should not be performed routinely in order to make considerable savings in money and time and to avoid unnecessary patient discomfort.

  16. Acute osteomyelitis complicating a simple fracture. A case report.

    PubMed

    Drummond-Webb, J J; Schnaid, E

    1983-11-26

    Osteomyelitis complicating a simple fracture is unusual, but the reason for its rarity is unknown. We report on a 9-year-old Black boy who developed acute osteomyelitis after sustaining an acute simple fracture of the femur. The causative role of trauma in acute osteomyelitis is discussed and 'the relative resistance of healthy bone' questioned.

  17. Implant material and design alter construct stiffness in distal femur locking plate fixation: a pilot study.

    PubMed

    Schmidt, Ulf; Penzkofer, Rainer; Bachmaier, Samuel; Augat, Peter

    2013-09-01

    Construct stiffness affects healing of bones fixed with locking plates. However, variable construct stiffness reported in the literature may be attributable to differing test configurations and direct comparisons may clarify these differences. We therefore asked whether different distal femur locking plate systems and constructs will lead to different (1) axial and rotational stiffness and (2) fatigue under cyclic loading. We investigated four plate systems for distal femur fixation (AxSOS, LCP, PERI-LOC, POLYAX) of differing designs and materials using bone substitutes in a distal femur fracture model (OTA/AO 33-A3). We created six constructs of each of the four plating systems. Stiffness under static and cyclic loading and fatigue under cyclic loading were measured. Mean construct stiffness under axial loading was highest for AxSOS (100.8 N/mm) followed by PERI-LOC (80.8 N/mm) and LCP (62.6 N/mm). POLYAX construct stiffness testing showed the lowest stiffness (51.7 N/mm) with 50% stiffness of AxSOS construct testing. Mean construct stiffness under torsional loading was similar in the group of AxSOS and PERI-LOC (3.40 Nm/degree versus 3.15 Nm/degree) and in the group of LCP and POLYAX (2.63 Nm/degree versus 2.56 Nm/degree). The fourth load level of > 75,000 cycles was reached by three of six AxSOS, three of six POLYAX, and two of six PERI-LOC constructs. All others including all LCP constructs failed earlier. Implant design and material of new-generation distal femur locking plate systems leads to a wide range of differences in construct stiffness. Assuming construct stiffness affects fracture healing, these data may influence surgical decision-making in choosing an implant system.

  18. Anterior knee pain and thigh muscle strength after intramedullary nailing of a tibial shaft fracture: an 8-year follow-up of 28 consecutive cases.

    PubMed

    Väistö, Olli; Toivanen, Jarmo; Kannus, Pekka; Järvinen, Markku

    2007-03-01

    Chronic anterior knee pain is a common complication after intramedullary nailing of a tibial shaft fracture. The source of pain is often not known, although it correlates with a simultaneous decrease in thigh muscle strength. No long-term follow-up study has assessed whether weakness of the thigh muscles is associated with anterior knee pain after the procedure in question. Prospective study. University Hospital of Tampere, University of Tampere. The muscular performance of 40 consecutive patients with a nailed tibial shaft fracture was tested isokinetically in a follow-up examination an average of 3.2 +/- 0.4 (SD) years after the initial surgery. An 8-year follow-up was possible in 28 of these cases. Isokinetic muscle strength measurements were made in 28 patients at an average 8.1 +/- 0.3 (SD) years after nail insertion and an average 6.6 +/- 0.3 (SD) years after nail extraction. All nails were extracted at an average 1.6 +/- 0.2 years after the nailing. : Seven patients were painless initially and still were at final follow-up (never pain, or NP). In 13 patients, the previous symptom of anterior knee pain was no longer present at final follow-up [pain, no pain (PNP)], and the remaining 8 had anterior knee pain initially and at final follow-up [always pain group (AP)]. With reference to the hamstring muscles, the mean peak torque difference between the injured and uninjured limb was -2.2% +/- 12% in the NP group, 1.6% +/- 15% in the PNP group, and 10.3% +/- 30% in the AP group at a speed of 60 degrees/second (Kruskal-Wallis test; chi(2) = 1.0; P = 0.593). At a speed of 180 degrees/second, the corresponding differences were -2.9% +/- 23% and 7.0% +/- 19% and 4.4% +/- 16% (Kruskal-Wallis test; chi = 1.7; P = 0.429). With reference to the quadriceps muscles, the mean peak torque difference was -2.8% +/- 9% in the NP group, 5.9% +/- 15% in the PNP group, and -13.0% +/- 16% in the AP group at a speed of 60 degrees/second (Kruskal-Wallis test; chi(2) = 7.9; P = 0

  19. Penile fracture: outcomes of early surgical intervention.

    PubMed

    Swanson, Daniel E W; Polackwich, A Scott; Helfand, Brian T; Masson, Puneet; Hwong, James; Dugi, Daniel D; Martinez Acevedo, Ann C; Hedges, Jason C; McVary, Kevin T

    2014-11-01

    To report a series of penile fractures, describing preoperative evaluation, surgical repair, and long-term outcomes. Medical records from Northwestern Memorial Hospital and Oregon Health & Science University from 2002 to 2011 were reviewed. Clinical presentation, preoperative evaluation, time from injury, mechanism and site of injury, and presence of urethral injury were assessed. Outcomes including erectile dysfunction, penile curvature, and voiding symptoms were evaluated using International Prostate Symptom Score and International Index of Erectile Function scores. Twenty-nine patients with 30 separate episodes of penile fractures presenting to the emergency room were identified. Mean patient age was 43 ± 9.6 years. The time from presentation to the initiation of surgery was 5.5 ± 4.4 hours. Mechanism of injury was intercourse in 26 of 30 fractures with the remaining attributed to masturbation or "rolling over." Immediate surgical repair was offered to all patients. Twenty-seven patients underwent surgery. Urethral injury was noted in 5 of the 27. The site of fracture was at the proximal shaft in 11, mid shaft in 12, and distal shaft in 4 patients. The mean follow-up period was 14.3 ± 15.8 weeks. Nine patients reported new mild erectile dysfunction or penile curvature. One patient reported new irritative voiding symptoms. The most common mechanism of penile fracture was from sexual intercourse, and frequent concomitant urethral injuries were observed. The frequency of concomitant urethral injury was higher than in previous studies. Although we observed high incidence of erectile dysfunction or penile curvature with early surgical repair, we retain it as the favored approach. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Slow Recovery of Weight Bearing After Stabilization of Long-Bone Fractures Using Elastic Stable Intramedullary Nails in Children.

    PubMed

    Lardelli, Patrizia; Frech-Dörfler, Martina; Holland-Cunz, Stefan; Mayr, Johannes

    2016-03-01

    Stabilization of diaphyseal long-bone fractures using elastic stable intramedullary nails (ESIN) in children promises early mobilization and rapid resumption of full weight bearing. We evaluated the duration of postoperative functional rehabilitation after ESIN, measured by the time from stabilization until first partial weight bearing, full weight bearing, and resumption of school sports. Fifty children with unstable, displaced fractures of the femur or lower leg treated with ESIN between 2002 and 2012 were included in this retrospective analysis. We classified fractures according to the pediatric comprehensive classification of fractures (PCCF). Thirty-five children sustained a femur fracture, and 15 children had a fracture of the lower leg or tibia. The surgeons in charge applied an additional plaster cast in 7 of 15 children who suffered a lower leg fracture. The postoperative time interval until full weight bearing in the group of children who had suffered transverse or short oblique femur fractures was significantly shorter (median: 4.4 weeks; range: 0.1-9.1 weeks) than that in the group who had sustained more complex fracture patterns (median: 6.8 weeks; range: 2.9-13.9 weeks; P = 0.04). Similarly, transverse and short oblique lower leg and tibia fractures required less time until full weight bearing (median: 4.1 weeks; range 2.7-6.0 weeks) than complex lower leg fractures (median: 6.1 weeks; range: 1.3-12.9 weeks; P = 0.04). ESIN proved fairly effective in restoring full weight bearing in transverse or short oblique fractures of the lower extremities but was less effective in complex fractures.

  1. Periprosthetic supracondylar femoral fractures following total knee arthroplasty: clinical comparison and related complications of the femur plate system and retrograde-inserted supracondylar nail.

    PubMed

    Gondalia, Viral; Choi, Duck Hyun; Lee, Su Chan; Nam, Chang Hyun; Hwang, Bo Hyun; Ahn, Hye Sun; Ong, Alvin C; Park, Ha Young; Jung, Kwang Am

    2014-09-01

    The purpose of this study is to analyze the clinical results and related complications of the femur plate system (FP) and the retrograde-inserted supracondylar nail (RISN). The study included 42 cases of periprosthetic supracondylar femoral fractures (PSF) proximal to posterior stabilized total knee arthroplasty between 2005 and 2009. Twenty-four cases of PSF were treated with the FP, and the other 18 cases were treated with the RISN. This study cohort was divided into subgroups according to the AO classification. We retrospectively compared the clinical results between the FP and RISN group. There were no significant differences between the two groups in terms of time of clinical union (p = 0.649). In the subgroup analysis, the mean operation time was significantly different only in subgroup A1 (p = 0.03). Complications were seen in 29.2 % (7/24) of patients in the FP group and 27.8 % (5/18) in the RISN group. The age during the index TKA and fracture fixation was a significant risk (p = 0.008) factor for complications between the two groups. No significant differences were found in the other factors between the two groups. The p value for operative time (p = 0.223), immobilization period (p = 0.129), ROM (p = 0.573), KSS (p = 0.379), KSS functional scores (p = 0.310) and time to union (p = 0.649). Clinical results did not differ according to the treatment methods used. Fixation method and fracture type did not cause an increase in the complication rate, but there was a trend toward higher non-union rates with the FP method and higher re-fracture rate with the RISN method. Noting the fact that only increasing age correlated with an increased complication rate, more careful attention should be paid to elderly patients in terms of both prevention and surgical care. Level III, therapeutic study.

  2. Bone Shaft Revascularization After Marrow Ablation Is Dramatically Accelerated in BSP-/- Mice, Along With Faster Hematopoietic Recolonization.

    PubMed

    Bouleftour, Wafa; Granito, Renata Neves; Vanden-Bossche, Arnaud; Sabido, Odile; Roche, Bernard; Thomas, Mireille; Linossier, Marie Thérèse; Aubin, Jane E; Lafage-Proust, Marie-Hélène; Vico, Laurence; Malaval, Luc

    2017-09-01

    The bone organ integrates the activity of bone tissue, bone marrow, and blood vessels and the factors ensuring this coordination remain ill defined. Bone sialoprotein (BSP) is with osteopontin (OPN) a member of the small integrin binding ligand N-linked glycoprotein (SIBLING) family, involved in bone formation, hematopoiesis and angiogenesis. In rodents, bone marrow ablation induces a rapid formation of medullary bone which peaks by ∼8 days (d8) and is blunted in BSP-/- mice. We investigated the coordinate hematopoietic and vascular recolonization of the bone shaft after marrow ablation of 2 month old BSP+/+ and BSP-/- mice. At d3, the ablated area in BSP-/- femurs showed higher vessel density (×4) and vascular volume (×7) than BSP+/+. Vessel numbers in the shaft of ablated BSP+/+ mice reached BSP-/- values only by d8, but with a vascular volume which was twice the value in BSP-/-, reflecting smaller vessel size in ablated mutants. At d6, a much higher number of Lin - (×3) as well as LSK (Lin - IL-7Rα - Sca-1 hi c-Kit hi , ×2) and hematopoietic stem cells (HSC: Flt3 - LSK, ×2) were counted in BSP-/- marrow, indicating a faster recolonization. However, the proportion of LSK and HSC within the Lin - was lower in BSP-/- and more differentiated stages were more abundant, as also observed in unablated bone, suggesting that hematopoietic differentiation is favored in the absence of BSP. Interestingly, unablated BSP-/- femur marrow also contains more blood vessels than BSP+/+, and in both intact and ablated shafts expression of VEGF and OPN are higher, and DMP1 lower in the mutants. In conclusion, bone marrow ablation in BSP-/- mice is followed by a faster vascular and hematopoietic recolonization, along with lower medullary bone formation. Thus, lack of BSP affects the interplay between hematopoiesis, angiogenesis, and osteogenesis, maybe in part through higher expression of VEGF and the angiogenic SIBLING, OPN. J. Cell. Physiol. 232: 2528-2537, 2017. © 2016

  3. Levothyroxine treatment and occurrence of fracture of the hip.

    PubMed

    Sheppard, Michael C; Holder, Roger; Franklyn, Jayne A

    2002-02-11

    Levothyroxine sodium is widely prescribed and has been implicated as a cause of reduction in bone mineral density and, therefore, suggested to be a major contributor to the risk of osteoporotic fractures. To investigate whether levothyroxine use increases the risk of developing osteoporotic fractures. We conducted a population-based, case-control analysis of the risk of a femur fracture in a large cohort of patients who had been prescribed levothyroxine. We used the United Kingdom General Practice (primary care) Research Database to identify 23,183 patients who had been prescribed long-term thyroid hormone therapy and to identify for each patient taking levothyroxine 4 controls matched for age, sex, primary care practice, and duration of registration on the database. The number of patients who had sustained a fracture of the proximal femur was ascertained for each group, together with drug therapies and medical diagnoses likely to affect fracture risk. Of the 23,183 patients prescribed thyroid hormone, a mean +/- SE of 1.61% +/- 0.08% had sustained a fracture of the femur, compared with 1.44% +/- 0.04% of 92,732 controls (P =.06). When analyzed according to sex, a significant difference in rate of fracture between patients taking levothyroxine and controls was found in males (P =.008). Compared with controls, patients taking levothyroxine had higher reported rates of medical diagnoses and therapies, potentially confounding the fracture risk. Independent predictors of the occurrence of fracture after adjustment for other factors were age (adjusted odds ratio [AOR], 1.11; 95% confidence interval [CI], 1.10-1.11; P<.001), medical diagnoses including rheumatoid arthritis (AOR in females, 1.69; 95% CI, 1.27-2.26; P<.001), excessive use of alcohol (AOR in females, 3.05; 95% CI, 1.94-4.76; P<.001), and prescription of drugs (eg, anticonvulsants; AOR in females, 2.49; 95% CI, 2.00-3.09; P<.001). Prescription of levothyroxine was an independent predictor of fracture

  4. Influence of the shaft rotation on the stability of magnetic fluid shaft seal characteristics

    NASA Astrophysics Data System (ADS)

    Krakov, M. S.; Nikiforov, I. V.

    2008-12-01

    Distribution of the magnetic particles concentration in a magnetic fluid shaft seal is studied numerically for a rotating shaft. It is revealed that the shaft rotation causes not only an azimuthal flow of the magnetic fluid, but a meridional flow as well. This meridional flow prevents the growth of magnetic particle concentration in the gap of the magnetic fluid shaft seal. As a result, the burst pressure of the magnetic fluid shaft seal for the rotating shaft is stable and does not change with time. Figs 6, Refs 7.

  5. [Intramedullary stabilisation of clavicula fractures].

    PubMed

    Prokop, A; Schiffer, G; Jubel, A; Chmielnicki, M

    2013-10-01

    With an incidence of 64/100,000, clavicular shaft fractures are one of the most common fractures. Intramedullary fixation with Prevot nails was initially reported in the late 1990s. This procedure offers minimally invasive stabilization of the fracture, thus enabling immediate mobilization and rapid loading capacity. Using a case study, the positioning and procedure are demonstrated on video. The intramedullary implant accommodates the varying tension loading of the clavicle. This treatment is ideal for clavicular fractures with 2-3 fragments. Compared to patients treated conservatively, operated patients achieve more rapid and improved mobility. Employment disability is shorter, and malunion occurs less frequently. Georg Thieme Verlag KG Stuttgart · New York.

  6. Further consideration of the curvature of the Neandertal Femur.

    PubMed

    Chapman, Tara; Sholukha, Victor; Semal, Patrick; Louryan, Stéphane; Van Sint Jan, Serge

    2018-01-01

    Neandertal femora are particularly known for having a marked sagittal femoral curvature. This study examined femoral curvature in Neandertals in comparison to a modern human population from Belgium by the use of three-dimensional (3D) quadric surfaces modeled from the bone surface. 3D models provide detailed information and enabled femoral curvature to be analyzed in conjunction with other morphological parameters. 3D models were created from CT scans of 75 modern human femora and 7 Neandertal femora. Quadric surfaces (QS) were created from the triangulated surface vertices in all areas of interest (neck, head, diaphyseal shaft, condyles) extracted from previously placed anatomical landmarks. The diaphyseal shaft was divided into five QS shapes and curvature was measured by degrees of difference between QS shapes. Each bone was placed in a local coordinate system enabling each bone to be analyzed in the same way. The use of 3D quadric surface fitting allowed the distribution of curvature with similarly curved femora to be analyzed and the different patterns of curvature between the two groups to be determined. The Neandertals were shown to have a higher degree of femoral curvature and a more distal point of femoral curvature than the modern human population from Belgium. Morphological aspects of the Neandertal femur are different from this modern human population although mainly seem unrelated to femoral curvature. The relative lack of correlations with other femoral bony morphological factors suggests femoral curvature variations may be related to other aspects. © 2017 Wiley Periodicals, Inc.

  7. Black bone disease in a healing fracture.

    PubMed

    Thiam, Desmond; Teo, Tse Yean; Malhotra, Rishi; Tan, Kong Bing; Chee, Yu Han

    2016-01-28

    Black bone disease refers to the hyperpigmentation of bone secondary to prolonged usage of minocycline. We present a report of a 34-year-old man who underwent femoral shaft fracture fixation complicated by deep infection requiring debridement. The implants were removed 10 months later after long-term treatment with minocycline and fracture union. A refracture of the femoral shaft occurred 2 days after implant removal and repeat fixation was required. Intraoperatively, abundant heavily pigmented and dark brown bone callus was noted over the old fracture site. There was no evidence of other bony pathology and the appearance was consistent with minocycline-associated pigmentation. As far as we are aware, this is the first case of black bone disease affecting callus within the interval period of bone healing. We also discuss the relevant literature on black bone disease to bring light on this rare entity that is an unwelcomed surprise to operating orthopaedic surgeons. 2016 BMJ Publishing Group Ltd.

  8. Pre-cementation of deep shaft

    NASA Astrophysics Data System (ADS)

    Heinz, W. F.

    1988-12-01

    Pre-cementation or pre-grouting of deep shafts in South Africa is an established technique to improve safety and reduce water ingress during shaft sinking. The recent completion of several pre-cementation projects for shafts deeper than 1000m has once again highlighted the effectiveness of pre-grouting of shafts utilizing deep slimline boreholes and incorporating wireline technique for drilling and conventional deep borehole grouting techniques for pre-cementation. Pre-cementation of deep shaft will: (i) Increase the safety of shaft sinking operation (ii) Minimize water and gas inflow during shaft sinking (iii) Minimize the time lost due to additional grouting operations during sinking of the shaft and hence minimize costly delays and standing time of shaft sinking crews and equipment. (iv) Provide detailed information of the geology of the proposed shaft site. Informations on anomalies, dykes, faults as well as reef (gold bearing conglomerates) intersections can be obtained from the evaluation of cores of the pre-cementation boreholes. (v) Provide improved rock strength for excavations in the immediate vicinity of the shaft area. The paper describes pre-cementation techniques recently applied successfully from surface and some conclusions drawn for further considerations.

  9. The assessment of bone mineral content and density of the lumbar spine and proximal femur in US submariners.

    PubMed

    Gasier, H G; Hughes, L M; Young, C R; Richardson, A M; Richardson, A R

    2014-09-01

    The submarine environment is unique in that there is limited space and no sunlight, which may negatively affect skeletal health and lead to accelerated bone loss, osteoporosis, and fractures. The primary purpose of this study was to determine whether there was an association with submarine service, specifically time spent at sea, and bone mineral content (BMC) and bone mineral density (BMD) of the lumbar spine and dual proximal femur (total hip and femoral neck) measured by DXA. This is a cross-sectional study of 462 submariners 20-91 years old. Variables included in the analysis were age, height, race, alcohol intake, tobacco use, fracture history, conditions, and medications known to cause bone loss and osteoporosis and submarine service. Of the submarine service predictors, only serving onboard a diesel submarine was determined to be independently associated with a reduction in BMD of the total hip and femur neck, while no submarine service predictor increased the odds of having low BMD. In submariners 50+ years old, the age-adjusted prevalence of osteopenia was 15.7 % (lumbar spine) and 40.4 % (femur neck), while the prevalence of osteoporosis was 4.8 % (lumbar spine) and 4.2 % (femur neck), rates that did not differ from NHANES 2005-2008. In submariners <50 years old, 3.1 % was below the expected range for age. The proportion of submariners 50+ years old that met the FRAX criteria for pharmacological treatment was 12 %. Intermittent periods of submergence that can range from a few days to 3+ months do not appear to compromise skeletal health differently than the general population.

  10. Rotary shaft seal

    DOEpatents

    Langebrake, C.O.

    1984-01-01

    The invention is a novel rotary shaft seal assembly which provides positive-contact sealing when the shaft is not rotated and which operates with its sealing surfaces separated by a film of compressed ambient gas whose width is independent of the speed of shaft rotation. In a preferred embodiment, the assembly includes a disc affixed to the shaft for rotation therewith. Axially movable, non-rotatable plates respectively supported by sealing bellows are positioned on either side of the disc to be in sealing engagement therewith. Each plate carries piezoelectric transucer elements which are electrically energized at startup to produce films of compressed ambient gas between the confronting surfaces of the plates and the disc. Following shutdown of the shaft, the transducer elements are de-energized. A control circuit responds to incipient rubbing between the plate and either disc by altering the electrical input to the transducer elements to eliminate rubbing.

  11. Rotary shaft seal

    DOEpatents

    Langebrake, Clair O.

    1984-01-01

    The invention is a novel rotary shaft seal assembly which provides positive-contact sealing when the shaft is not rotated and which operates with its sealing surfaces separated by a film of compressed ambient gas whose width is independent of the speed of shaft rotation. In a preferred embodiment, the assembly includes a disc affixed to the shaft for rotation therewith. Axially movable, non-rotatable plates respectively supported by sealing bellows are positioned on either side of the disc to be in sealing engagement therewith. Each plate carries piezoelectric transducer elements which are electrically energized at startup to produce films of compressed ambient gas between the confronting surfaces of the plates and the disc. Following shutdown of the shaft, the transducer elements are de-energized. A control circuit responds to incipient rubbing between the plate and either disc by altering the electrical input to the transducer elements to eliminate rubbing.

  12. Pattern of Cortical Fracture following Corticotomy for Distraction Osteogenesis.

    PubMed

    Luvan, M; Kanthan, S R; Roshan, G; Saw, A

    2015-11-01

    Corticotomy is an essential procedure for deformity correction and there are many techniques described. However there is no proper classification of the fracture pattern resulting from corticotomies to enable any studies to be conducted. We performed a retrospective study of corticotomy fracture patterns in 44 patients (34 tibias and 10 femurs) performed for various indications. We identified four distinct fracture patterns, Type I through IV classification based on the fracture propagation following percutaneous corticotomy. Type I transverse fracture, Type II transverse fracture with a winglet, Type III presence of butterfly fragment and Type IV fracture propagation to a fixation point. No significant correlation was noted between the fracture pattern and the underlying pathology or region of corticotomy.

  13. Pattern of Cortical Fracture following Corticotomy for Distraction Osteogenesis

    PubMed Central

    Luvan, M; Roshan, G; Saw, A

    2015-01-01

    Corticotomy is an essential procedure for deformity correction and there are many techniques described. However there is no proper classification of the fracture pattern resulting from corticotomies to enable any studies to be conducted. We performed a retrospective study of corticotomy fracture patterns in 44 patients (34 tibias and 10 femurs) performed for various indications. We identified four distinct fracture patterns, Type I through IV classification based on the fracture propagation following percutaneous corticotomy. Type I transverse fracture, Type II transverse fracture with a winglet, Type III presence of butterfly fragment and Type IV fracture propagation to a fixation point. No significant correlation was noted between the fracture pattern and the underlying pathology or region of corticotomy. PMID:28611907

  14. The AO Pediatric Comprehensive Classification of Long Bone Fractures (PCCF)

    PubMed Central

    Audigé, Laurent; Slongo, Theddy; Lutz, Nicolas; Blumenthal, Andrea; Joeris, Alexander

    2017-01-01

    Background and purpose The AO Pediatric Comprehensive Classification of Long Bone Fractures (PCCF) describes the localization and morphology of fractures, and considers severity in 2 categories: (1) simple, and (2) multifragmentary. We evaluated simple and multifragmentary fractures in a large consecutive cohort of children diagnosed with long bone fractures in Switzerland. Patients and methods Children and adolescents treated for fractures between 2009 and 2011 at 2 tertiary pediatric surgery hospitals were retrospectively included. Fractures were classified according to the AO PCCF. Severity classes were described according to fracture location, patient age and sex, BMI, and cause of trauma. Results Of all trauma events, 3% (84 of 2,730) were diagnosed with a multifragmentary fracture. This proportion was age-related: 2% of multifragmentary fractures occurred in school­children and 7% occurred in adolescents. In patients diagnosed with a single fracture only, the highest percentage of multifragmentation occurred in the femur (12%, 15 of 123). In fractured paired radius/ulna bones, multifragmentation occurred in 2% (11 of 687); in fractured paired tibia/fibula bones, it occurred in 21% (24 of 115), particularly in schoolchildren (5 of 18) and adolescents (16 of 40). In a multivariable regression model, age, cause of injury, and bone were found to be relevant prognostic factors of multifragmentation (odds ratio (OR) > 2). Interpretation Overall, multifragmentation in long bone fractures in children was rare and was mostly observed in adolescents. The femur was mostly affected in single fractures and the lower leg was mostly affected in paired-bone fractures. The clinical relevance of multifragmentation regarding growth and long-term functional recovery remains to be determined. PMID:27882814

  15. The AO Pediatric Comprehensive Classification of Long Bone Fractures (PCCF).

    PubMed

    Audigé, Laurent; Slongo, Theddy; Lutz, Nicolas; Blumenthal, Andrea; Joeris, Alexander

    2017-04-01

    Background and purpose - The AO Pediatric Comprehensive Classification of Long Bone Fractures (PCCF) describes the localization and morphology of fractures, and considers severity in 2 categories: (1) simple, and (2) multifragmentary. We evaluated simple and multifragmentary fractures in a large consecutive cohort of children diagnosed with long bone fractures in Switzerland. Patients and methods - Children and adolescents treated for fractures between 2009 and 2011 at 2 tertiary pediatric surgery hospitals were retrospectively included. Fractures were classified according to the AO PCCF. Severity classes were described according to fracture location, patient age and sex, BMI, and cause of trauma. Results - Of all trauma events, 3% (84 of 2,730) were diagnosed with a multifragmentary fracture. This proportion was age-related: 2% of multifragmentary fractures occurred in school-children and 7% occurred in adolescents. In patients diagnosed with a single fracture only, the highest percentage of multifragmentation occurred in the femur (12%, 15 of 123). In fractured paired radius/ulna bones, multifragmentation occurred in 2% (11 of 687); in fractured paired tibia/fibula bones, it occurred in 21% (24 of 115), particularly in schoolchildren (5 of 18) and adolescents (16 of 40). In a multivariable regression model, age, cause of injury, and bone were found to be relevant prognostic factors of multifragmentation (odds ratio (OR) > 2). Interpretation - Overall, multifragmentation in long bone fractures in children was rare and was mostly observed in adolescents. The femur was mostly affected in single fractures and the lower leg was mostly affected in paired-bone fractures. The clinical relevance of multifragmentation regarding growth and long-term functional recovery remains to be determined.

  16. Preventing painful age-related bone fractures: Anti-sclerostin therapy builds cortical bone and increases the proliferation of osteogenic cells in the periosteum of the geriatric mouse femur.

    PubMed

    Thompson, Michelle L; Chartier, Stephane R; Mitchell, Stefanie A; Mantyh, Patrick W

    2016-01-01

    Age-related bone fractures are usually painful and have highly negative effects on a geriatric patient's functional status, quality of life, and survival. Currently, there are few analgesic therapies that fully control bone fracture pain in the elderly without significant unwanted side effects. However, another way of controlling age-related fracture pain would be to preemptively administer an osteo-anabolic agent to geriatric patients with high risk of fracture, so as to build new cortical bone and prevent the fracture from occurring. A major question, however, is whether an osteo-anabolic agent can stimulate the proliferation of osteogenic cells and build significant amounts of new cortical bone in light of the decreased number and responsiveness of osteogenic cells in aging bone. To explore this question, geriatric and young mice, 20 and 4 months old, respectively, received either vehicle or a monoclonal antibody that sequesters sclerostin (anti-sclerostin) for 28 days. From days 21 to 28, animals also received sustained administration of the thymidine analog, bromodeoxyuridine (BrdU), which labels the DNA of dividing cells. Animals were then euthanized at day 28 and the femurs were examined for cortical bone formation, bone mineral density, and newly borne BrdU+ cells in the periosteum which is a tissue that is pivotally involved in the formation of new cortical bone. In both the geriatric and young mice, anti-sclerostin induced a significant increase in the thickness of the cortical bone, bone mineral density, and the proliferation of newly borne BrdU+ cells in the periosteum. These results suggest that even in geriatric animals, anti-sclerostin therapy can build new cortical bone and increase the proliferation of osteogenic cells and thus reduce the likelihood of painful age-related bone fractures. © The Author(s) 2016.

  17. Influence of Regional Difference in Bone Mineral Density on Hip Fracture Site in Elderly Females by Finite Element Analysis.

    PubMed

    Lin, Z L; Li, P F; Pang, Z H; Zheng, X H; Huang, F; Xu, H H; Li, Q L

    2015-11-01

    Hip fracture is a kind of osteoporotic fractures in elderly patients. Its important monitoring indicator is to measure bone mineral density (BMD) using DXA. The stress characteristics and material distribution in different parts of the bones can be well simulated by three-dimensional finite element analysis. Our previous studies have demonstrated a linear positive correlation between clinical BMD and the density of three-dimensional finite element model of the femur. However, the correlation between the density variation between intertrochanteric region and collum femoris region of the model and the fracture site has not been studied yet. The present study intends to investigate whether the regional difference in the density of three-dimensional finite element model of the femur can be used to predict hip fracture site in elderly females. The CT data of both hip joints were collected from 16 cases of elderly female patients with hip fractures. Mimics 15.01 software was used to reconstruct the model of proximal femur on the healthy side. Ten kinds of material properties were assigned. In Abaqus 6.12 software, the collum femoris region and intertrochanteric region were, respectively, drawn for calculating the corresponding regional density of the model, followed by prediction of hip fracture site and final comparison with factual fracture site. The intertrochanteric region/collum femoris region density was [(1.20 ± 0.02) × 10(6)] on the fracture site and [(1.22 ± 0.03) × 10(6)] on the non-fracture site, and the difference was statistically significant (P = 0.03). Among 16 established models of proximal femur on the healthy side, 14 models were consistent with the actual fracture sites, one model was inconsistent, and one model was unpredictable, with the coincidence rate of 87.5 %. The intertrochanteric region or collum femoris region with lower BMD is more prone to hip fracture of the type on the corresponding site.

  18. Reassessment of osteoporosis-related femoral fractures and economic burden in Saudi Arabia.

    PubMed

    Sadat-Ali, Mir; Al-Dakheel, Dakheel A; Azam, Md Q; Al-Bluwi, Mohammed T; Al-Farhan, Mohammed F; AlAmer, Hussein A; Al-Meer, Zakaria; Al-Mohimeed, Abdallah; Tabash, Ibrahim K; Karry, Maher O; Rassasy, Yaseen M; Baragaba, Mohammed A; Amer, Ahmed S; AlJawder, Abdallah; Al-Bouri, Kamil M; ElTinay, Mohammed; Badawi, Hamed A; Al-Othman, Abdallah A; Tayara, Badar K; Al-Faraidy, Moaad H; Amin, Ahmed H

    2015-01-01

    The current study reassesses the prevalence of fragility fractures and lifetime costs in the Eastern Province of Saudi Arabia. Forty-two percent (391) of the fractures were at the neck of the femur, and 38.6 % (354) were inter-trochanteric fractures. The overall incidence was assessed to be 7528 (1,300,336 population 55 years or older) with the direct cost of SR564.75 million ($150.60 million). A National Fracture Registry and osteoporosis awareness programs are recommended. Proximal femur fragility fractures are reported to be increasing worldwide due to increased life expectancy. The current study is carried out to assess the incidence of such fractures in the Eastern Province of Saudi Arabia and to assess the costs incurred in managing them annually. Finally, by extrapolating the data, the study can calculate the overall economic burden in Saudi Arabia. The data of fragility proximal femur fractures was collected from 24 of 28 hospitals in the Eastern Province. The data included age, sex, mode of injury, type of fracture, prescribed drug (and its cost), and length of hospital stay. Population statistics were obtained from the Department of Statistics of the Saudi Arabian government Web site. Twenty-four hospitals (85 %) participated in the study. A total of 780 fractures were sustained by 681 patients. Length of stay in the hospital averaged 23.28 ± 13.08 days. The projected fracture rate from all the hospitals would be 917 (an incidence of 5.81/1000), with a total cost of SR68.77 million. Further extrapolation showed that the overall incidence could be 7528 (1,300,336 population 55 years or older) with the direct cost of SR564.75 million ($150.60 million). Osteoporosis-related femoral fractures in Saudi Arabia are significant causes of morbidity besides incurring economic burden. We believe that a National Fracture Registry needs to be established, and osteoporosis awareness programs should be instituted in every part of Saudi Arabia so that these patients can

  19. Slow Recovery of Weight Bearing After Stabilization of Long-Bone Fractures Using Elastic Stable Intramedullary Nails in Children

    PubMed Central

    Lardelli, Patrizia; Frech-Dörfler, Martina; Holland-Cunz, Stefan; Mayr, Johannes

    2016-01-01

    Abstract Stabilization of diaphyseal long-bone fractures using elastic stable intramedullary nails (ESIN) in children promises early mobilization and rapid resumption of full weight bearing. We evaluated the duration of postoperative functional rehabilitation after ESIN, measured by the time from stabilization until first partial weight bearing, full weight bearing, and resumption of school sports. Fifty children with unstable, displaced fractures of the femur or lower leg treated with ESIN between 2002 and 2012 were included in this retrospective analysis. We classified fractures according to the pediatric comprehensive classification of fractures (PCCF). Thirty-five children sustained a femur fracture, and 15 children had a fracture of the lower leg or tibia. The surgeons in charge applied an additional plaster cast in 7 of 15 children who suffered a lower leg fracture. The postoperative time interval until full weight bearing in the group of children who had suffered transverse or short oblique femur fractures was significantly shorter (median: 4.4 weeks; range: 0.1–9.1 weeks) than that in the group who had sustained more complex fracture patterns (median: 6.8 weeks; range: 2.9–13.9 weeks; P = 0.04). Similarly, transverse and short oblique lower leg and tibia fractures required less time until full weight bearing (median: 4.1 weeks; range 2.7–6.0 weeks) than complex lower leg fractures (median: 6.1 weeks; range: 1.3–12.9 weeks; P = 0.04). ESIN proved fairly effective in restoring full weight bearing in transverse or short oblique fractures of the lower extremities but was less effective in complex fractures. PMID:26986106

  20. Pathologic femur fracture due to a brown tumor in a patient with secondary hyperparathyroidism and vitamin D-resistant rickets.

    PubMed

    Wallace, Eric; Day, Matthew; Fadare, Oluwole; Schaefer, Heidi

    2013-02-01

    Vitamin D-resistant rickets is the common clinical outcome of multiple genetic mutations that alter the regulation of phosphorus and vitamin D metabolism, mainly through their effects on fibroblast growth factor 23 (FGF-23). These diseases typically present in childhood with the classic physical examination finding of nutritional rickets, such as genu varum/valgum and rachitic rosary. Treatment, which is aimed at improving severe bone disease with vitamin D and phosphorus supplementation, can cause secondary hyperparathyroidism and/or kidney failure from nephrocalcinosis over the life of the patient. Although FGF-23 has been shown to downregulate parathyroid hormone in vitro, its effect on parathyroid secretion in disease states such as chronic kidney disease and X-linked hypophosphatemic rickets is unclear because elevations in FGF-23 and parathyroid hormone levels characterize both of these disease states. We describe a case of vitamin D-resistant rickets that presented with a femur fracture through a brown tumor. Radiographs show the combination of severe bony abnormalities associated with both long-standing hyperparathyroidism and vitamin D-resistant rickets. Copyright © 2013 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  1. SEAL FOR ROTATING SHAFT

    DOEpatents

    Coffman, R.T.

    1957-12-10

    A seal is described for a rotatable shaft that must highly effective when the shaft is not rotating but may be less effective while the shaft is rotating. Weights distributed about a sealing disk secured to the shaft press the sealing disk against a tubular section into which the shiilt extends, and whem the shaft rotates, the centrifugal forces on the weights relieve the pressurc of the sealing disk against the tubular section. This action has the very desirible result of minimizing the wear of the rotating disk due to contact with the tubular section, while affording maximum sealing action when it is needed.

  2. Fat embolism: special situations bilateral femoral fractures and pathologic femoral fractures.

    PubMed

    Kontakis, George M; Tossounidis, Theodoros; Weiss, Kurt; Pape, Hans-Christoph; Giannoudis, Peter V

    2006-10-01

    Few data are available in the literature regarding fat embolism in cases of bilateral femoral and pathological femoral fractures. The incidence of bilateral femoral fractures ranges from 2-9.5% of the total number of patients with femoral fractures, and they usually occur in high energy trauma and multi-trauma patients. Although injury severity scores tend to underestimate the severity of these injuries, fat embolism seems to occur in increased frequency ranging from 4.8-7.5%. Intramedullary nailing, which is the preferred surgical treatment, triggers a systemic inflammatory response that poses an additional burden to pulmonary function. In addition, the femur is a common site of metastatic bone disease. The treatment of impending and actual pathological fractures is complicated by increased rates of lung damage due to various factors. Fat embolism during treatment--mainly with intramedullary nails--generally seems to range from 0-10%.

  3. [Treatment of periprosthetic femoral fractures after total hip arthroplasty with specially constructed retrograde hollow nails].

    PubMed

    Szalay, G; Meyer, C; Mika, J; Schnettler, R; Thormann, U

    2014-12-01

    Treatment of periprosthetic fractures by implantation of a specially constructed, retrograde hollow nail which fits over the tip of the prosthesis and becomes locked on it. Periprosthetic femoral fractures with firmly anchored prosthesis shaft after total hip arthroplasty of types B1 and C according to the Vancouver classification. Loosened prosthesis (type B2/B3) and trochanteric fractures (type A). Broken or damaged prosthesis, florid inflammation and soft tissue injuries in the operation field, contracted knee joint, advanced deformation in the knee joint and distal femur, enclosed prosthesis and general contraindications. In a supine position the periprosthetic fracture is exposed via a lateral access. For cemented prostheses the cement is removed around the tip of the prosthesis (at least 2-3 cm) and medullary cavity. Arthrotomy with flexion of the knee joint and marking of the nail entry point. Drill the medullary cavity, retrograde introduction of the nail, visually fit the nail over the tip of the prosthesis and lock the nail with the prosthesis. If necessary use additional spongiosaplasty or also placement of additional cerclages depending on fracture type and size of the defect zone. Lock the nail distally. Use intraoperative radiological imaging to control correct positioning and length of the nail. Close the wound layer by layer with placement of suction drainage devices and dressing. Partial loading for 6 weeks with a subsequent pain-adapted loading gradient until full loading is possible. If selective partial loading is not possible, a decision must be made in individual cases as to whether the intraoperative findings allow immediate full loading. From 2004 to 2011 a total of 25 periprosthetic femoral fractures in 25 patients were treated in 2 locations using specially constructed slotted hollow nails. Within the framework of a retrospective study 20 of these patients (16 female and 4 male; average age 77.2 [72-84] years) were clinically and

  4. Do thoraco-lumbar spinal injuries classification systems exhibit lower inter- and intra-observer agreement than other fractures classifications?: A comparison using fractures of the trochanteric area of the proximal femur as contrast model.

    PubMed

    Urrutia, Julio; Zamora, Tomas; Klaber, Ianiv; Carmona, Maximiliano; Palma, Joaquin; Campos, Mauricio; Yurac, Ratko

    2016-04-01

    It has been postulated that the complex patterns of spinal injuries have prevented adequate agreement using thoraco-lumbar spinal injuries (TLSI) classifications; however, limb fracture classifications have also shown variable agreements. This study compared agreement using two TLSI classifications with agreement using two classifications of fractures of the trochanteric area of the proximal femur (FTAPF). Six evaluators classified the radiographs and computed tomography scans of 70 patients with acute TLSI using the Denis and the new AO Spine thoraco-lumbar injury classifications. Additionally, six evaluators classified the radiographs of 70 patients with FTAPF using the Tronzo and the AO schemes. Six weeks later, all cases were presented in a random sequence for repeat assessment. The Kappa coefficient (κ) was used to determine agreement. Inter-observer agreement: For TLSI, using the AOSpine classification, the mean κ was 0.62 (0.57-0.66) considering fracture types, and 0.55 (0.52-0.57) considering sub-types; using the Denis classification, κ was 0.62 (0.59-0.65). For FTAPF, with the AO scheme, the mean κ was 0.58 (0.54-0.63) considering fracture types and 0.31 (0.28-0.33) considering sub-types; for the Tronzo classification, κ was 0.54 (0.50-0.57). Intra-observer agreement: For TLSI, using the AOSpine scheme, the mean κ was 0.77 (0.72-0.83) considering fracture types, and 0.71 (0.67-0.76) considering sub-types; for the Denis classification, κ was 0.76 (0.71-0.81). For FTAPF, with the AO scheme, the mean κ was 0.75 (0.69-0.81) considering fracture types and 0.45 (0.39-0.51) considering sub-types; for the Tronzo classification, κ was 0.64 (0.58-0.70). Using the main types of AO classifications, inter- and intra-observer agreement of TLSI were comparable to agreement evaluating FTAPF; including sub-types, inter- and intra-observer agreement evaluating TLSI were significantly better than assessing FTAPF. Inter- and intra-observer agreements using the Denis

  5. Critical differences between subtrochanteric and diaphyseal atypical femoral fractures: analyses of 51 cases at a single institution in Korean population.

    PubMed

    Cho, Yoon-Je; Kang, Kyung-Chung; Chun, Young-Soo; Rhyu, Kee Hyung; Kim, Sang-Jun; Jang, Tae-Su

    2018-05-03

    There still remains controversy on the pathomechanism of atypical femoral fracture (AFF). The angle of lateral bowing and bone mineral density showed significant differences between subtrochanteric and diaphyseal atypical fracture groups. In addition to the use of bisphosphonate, mechanical factors might play important roles in the occurrence of AFFs. Although AFF could be divided into subtrochanteric and diaphyseal fracture according to the location of fractures, there is a lack of evidence regarding differences between two fractures and etiology of the occurrence. The aim of study is to determine differences between atypical subtrochanteric and diaphyseal fracture in Korean population. Between February 2010 and March 2015, 51 AFFs in 40 patients were included in this study. Their medical records were retrospectively reviewed. The AFF patients satisfied all the diagnostic criteria of the 2014 revised edition of the ASMBR. To analyze the differences according to the location of fracture, the AFFs were divided into subtrochanteric (n = 16) and diaphyseal (n = 35) fracture groups. The following factors were compared between two groups: patients' demographics, underlying diseases, laboratory findings (serum-25(OH) VitD3, osteocalcin, c-telopeptide, ALP, Ca, and P), bone mineral density (BMD), duration of bisphosphonate (BP) usage, and lateral bowing of the femur at time of the fracture. All AFFs happened in female patients (mean age, 73.8 years) who have received bisphosphonate treatments except three patients. The mean duration of bisphosphonate usage was 95.3 months. Between the two groups, demographic data (age, height, weight, and BMI), underlying diseases, laboratory findings, hip BMD, and duration of BP treatment were comparable to each other (p > 0.05). However, the subtrochanteric fracture group showed higher FNSBA (femoral neck shaft bowing angle, p < 0.001) and spine BMD (p = 0.014) compared to the diaphyseal fracture group. Angle of

  6. Type 2 Diabetes and Metformin Influence on Fracture Healing in an Experimental Rat Model.

    PubMed

    La Fontaine, Javier; Chen, Chris; Hunt, Nathan; Jude, Edward; Lavery, Lawrence

    2016-01-01

    Persons with diabetes have a greater incidence of fractures compared with persons without diabetes. However, very little published information is available concerning the deleterious effect of late-stage diabetes on osseous structure and bone healing. The purpose of the present study was to evaluate the role of diabetes on fracture healing in a rat femur repair model. Thirty-six lean and diabetic Zucker rats were subdivided into 3 groups: (1) 12 lean rats as the control group; (2) 12 diabetic rats without blood glucose control (DM group); and (3) 12 diabetic rats treated with 300 mg/kg metformin to reduce the blood glucose levels (DM + Met group). Radiographs were taken every week to determine the incidence of bone repair and delayed union. All the rats were killed at 6 weeks after surgery. In both the sham-operated and the fractured and repaired femurs, significant decreases in the fracture-load/weight and marginal decreases in the fracture-load between the lean and DM groups were found. Metformin treatment significantly reduced the blood glucose and body weight 12 days postoperatively. Furthermore, a decrease in the fracture-load and fracture-load/weight in the repaired femurs was found in the DM + Met group. Diabetes impairs bone fracture healing. Metformin treatment reduces the blood glucose and body weight but had an adverse effect on fracture repair in diabetic rats. Further investigations are needed to reveal the mechanisms responsible for the effects of type 2 diabetes mellitus on bone and bone quality and the effect of medications such as metformin might have in diabetic bone in the presence of neuropathy and vascular disease. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  7. Statistical Analyses of Femur Parameters for Designing Anatomical Plates.

    PubMed

    Wang, Lin; He, Kunjin; Chen, Zhengming

    2016-01-01

    Femur parameters are key prerequisites for scientifically designing anatomical plates. Meanwhile, individual differences in femurs present a challenge to design well-fitting anatomical plates. Therefore, to design anatomical plates more scientifically, analyses of femur parameters with statistical methods were performed in this study. The specific steps were as follows. First, taking eight anatomical femur parameters as variables, 100 femur samples were classified into three classes with factor analysis and Q-type cluster analysis. Second, based on the mean parameter values of the three classes of femurs, three sizes of average anatomical plates corresponding to the three classes of femurs were designed. Finally, based on Bayes discriminant analysis, a new femur could be assigned to the proper class. Thereafter, the average anatomical plate suitable for that new femur was selected from the three available sizes of plates. Experimental results showed that the classification of femurs was quite reasonable based on the anatomical aspects of the femurs. For instance, three sizes of condylar buttress plates were designed. Meanwhile, 20 new femurs are judged to which classes the femurs belong. Thereafter, suitable condylar buttress plates were determined and selected.

  8. Mechanical torque measurement for in vivo quantification of bone strength in the proximal femur.

    PubMed

    Mueller, Marc Andreas; Hengg, Clemens; Hirschmann, Michael; Schmid, Denise; Sprecher, Christoph; Audigé, Laurent; Suhm, Norbert

    2012-10-01

    Bone strength determines fracture risk and fixation strength of osteosynthesis implants. In vivo, bone strength is currently measured indirectly by quantifying bone mineral density (BMD) which is however only one determinant of the bone's biomechanical competence besides the bone's macro- and micro-architecture and tissue related parameters. We have developed a measurement principle (DensiProbe™ Hip) for direct, mechanical quantification of bone strength within the proximal femur upon hip fracture fixation. Previous cadaver tests indicated a close correlation between DensiProbe™ Hip measurements, 3D micro-CT analysis and biomechanical indicators of bone strength. The goal of this study was to correlate DensiProbe™ Hip measurements with areal bone mineral density (BMD). Forty-three hip fracture patients were included in this study. Intraoperatively, DensiProbe™ Hip was inserted to the subsequent hip screw tip position within the femoral head. Peak torque to breakaway of local cancellous bone was registered. Thirty-seven patients underwent areal BMD measurements of the contralateral proximal femur. Failure of fixation was assessed radio graphically 6 and 12 weeks postoperatively. Peak torque and femoral neck BMD showed significant correlations (R=0.60, P=0.0001). In regression analysis, areal BMD explained 46% of femoral neck BMD variance in a quadratic relationship. Throughout the 12-week follow-up period, no failure of fixation was observed. DensiProbe™ Hip may capture variations of bone strength beyond areal BMD which are currently difficult to measure in vivo. A multicenter study will clarify if peak torque predicts fixation failure. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. Injury risk functions based on population-based finite element model responses: Application to femurs under dynamic three-point bending.

    PubMed

    Park, Gwansik; Forman, Jason; Kim, Taewung; Panzer, Matthew B; Crandall, Jeff R

    2018-02-28

    The goal of this study was to explore a framework for developing injury risk functions (IRFs) in a bottom-up approach based on responses of parametrically variable finite element (FE) models representing exemplar populations. First, a parametric femur modeling tool was developed and validated using a subject-specific (SS)-FE modeling approach. Second, principal component analysis and regression were used to identify parametric geometric descriptors of the human femur and the distribution of those factors for 3 target occupant sizes (5th, 50th, and 95th percentile males). Third, distributions of material parameters of cortical bone were obtained from the literature for 3 target occupant ages (25, 50, and 75 years) using regression analysis. A Monte Carlo method was then implemented to generate populations of FE models of the femur for target occupants, using a parametric femur modeling tool. Simulations were conducted with each of these models under 3-point dynamic bending. Finally, model-based IRFs were developed using logistic regression analysis, based on the moment at fracture observed in the FE simulation. In total, 100 femur FE models incorporating the variation in the population of interest were generated, and 500,000 moments at fracture were observed (applying 5,000 ultimate strains for each synthesized 100 femur FE models) for each target occupant characteristics. Using the proposed framework on this study, the model-based IRFs for 3 target male occupant sizes (5th, 50th, and 95th percentiles) and ages (25, 50, and 75 years) were developed. The model-based IRF was located in the 95% confidence interval of the test-based IRF for the range of 15 to 70% injury risks. The 95% confidence interval of the developed IRF was almost in line with the mean curve due to a large number of data points. The framework proposed in this study would be beneficial for developing the IRFs in a bottom-up manner, whose range of variabilities is informed by the population

  10. Ballistic fractures: indirect fracture to bone.

    PubMed

    Dougherty, Paul J; Sherman, Don; Dau, Nathan; Bir, Cynthia

    2011-11-01

    Two mechanisms of injury, the temporary cavity and the sonic wave, have been proposed to produce indirect fractures as a projectile passes nearby in tissue. The purpose of this study is to evaluate the temporal relationship of pressure waves using strain gauge technology and high-speed video to elucidate whether the sonic wave, the temporary cavity, or both are responsible for the formation of indirect fractures. Twenty-eight fresh frozen cadaveric diaphyseal tibia (2) and femurs (26) were implanted into ordnance gelatin blocks. Shots were fired using 9- and 5.56-mm bullets traversing through the gelatin only, passing close to the edge of the bone, but not touching, to produce an indirect fracture. High-speed video of the impact event was collected at 20,000 frames/s. Acquisition of the strain data were synchronized with the video at 20,000 Hz. The exact time of fracture was determined by analyzing and comparing the strain gauge output and video. Twenty-eight shots were fired, 2 with 9-mm bullets and 26 with 5.56-mm bullets. Eight indirect fractures that occurred were of a simple (oblique or wedge) pattern. Comparison of the average distance of the projectile from the bone was 9.68 mm (range, 3-20 mm) for fractured specimens and 15.15 mm (range, 7-28 mm) for nonfractured specimens (Student's t test, p = 0.036). In this study, indirect fractures were produced after passage of the projectile. Thus, the temporary cavity, not the sonic wave, was responsible for the indirect fractures.

  11. Femoral fracture repair and postoperative management in new zealand white rabbits.

    PubMed

    Reuter, Jon D; Ovadia, Shira; Howell, Paula; Jaskwich, David H

    2002-07-01

    Low bone density and large muscle mass predispose rabbits to femoral fractures. However, there are few reports describing treatment and prognosis. Two New Zealand White rabbits presented with unilateral left rear limb abduction and lateral rotation of the distal left rear limb 2 and 17 days after experimental surgery to create a "stair step" in the patellar groove of the left medial femoral chondyle. This procedure was performed after approval by the Institutional Animal Care and Use Committee. Radiography revealed a spiral oblique mid-shaft fracture of the left femur in both rabbits. Open fracture reduction was undertaken. Because of the presence of screws and Kirschner-wires in the medial femoral condyle, a lateral approach to surgical correction was chosen. Intramedullary fixation was used to reduce and stabilize the fractures. A 0.062" Kirschner wire was selected for the intramedullary device, because it was sufficiently flexible to allow easy passage into the femoral canal while being sufficiently stiff to promote reduction of the fracture. In addition, the ends of the fracture were secured with a 0.032" Kirschner cerclage wire to provide additional control of rotation and angulation. Then we assessed the range of motion of the knee joint to determine fracture stability and ensure that the hardware did not impinge on soft-tissue elements. After closure and application of sterile dressing, the hind legs were hobbled proximal to the hock by using elastic veterinary wrap in a figure-eight pattern to maintain limb alignment and prevent formation of pressure ulcers. Intraoperative fluoroscopic evaluation and postoperative radiographs confirmed fracture reduction. Bruising and seroma formation occurred at the surgical site, and transient anorexia developed. Rabbits were treated with fluids, analgesics, antibiotics, and fitted with Elizabethan collars. They were housed in isolation to limit excessive environmental stimulation, which could alarm them and provoke

  12. Trabecular bone analysis in CT and X-ray images of the proximal femur for the assessment of local bone quality.

    PubMed

    Fritscher, Karl; Grunerbl, Agnes; Hanni, Markus; Suhm, Norbert; Hengg, Clemens; Schubert, Rainer

    2009-10-01

    Currently, conventional X-ray and CT images as well as invasive methods performed during the surgical intervention are used to judge the local quality of a fractured proximal femur. However, these approaches are either dependent on the surgeon's experience or cannot assist diagnostic and planning tasks preoperatively. Therefore, in this work a method for the individual analysis of local bone quality in the proximal femur based on model-based analysis of CT- and X-ray images of femur specimen will be proposed. A combined representation of shape and spatial intensity distribution of an object and different statistical approaches for dimensionality reduction are used to create a statistical appearance model in order to assess the local bone quality in CT and X-ray images. The developed algorithms are tested and evaluated on 28 femur specimen. It will be shown that the tools and algorithms presented herein are highly adequate to automatically and objectively predict bone mineral density values as well as a biomechanical parameter of the bone that can be measured intraoperatively.

  13. Femoral nerve block Intervention in Neck of Femur fracture (FINOF): study protocol for a randomized controlled trial

    PubMed Central

    2014-01-01

    Background Hip fractures are very painful leading to lengthy hospital stays. Conventional methods of treating pain are limited. Non-steroidal anti-inflammatories are relatively contraindicated and opioids have significant side effects.Regional anaesthesia holds promise but results from these techniques are inconsistent. Trials to date have been inconclusive with regard to which blocks to use and for how long. Interpatient variability remains a problem. Methods/Design This is a single centre study conducted at Queen’s Medical Centre, Nottingham; a large regional trauma centre in England. It is a pragmatic, parallel arm, randomized controlled trial. Sample size will be 150 participants (75 in each group). Randomization will be web-based, using computer generated concealed tables (service provided by Nottingham University Clinical Trials Unit). There is no blinding. Intervention will be a femoral nerve block (0.5 mls/kg 0.25% levo-bupivacaine) followed by ropivacaine (0.2% 5 ml/hr−1) infused via a femoral nerve catheter until 48 hours post-surgery. The control group will receive standard care. Participants will be aged over 70 years, cognitively intact (abbreviated mental score of seven or more), able to provide informed consent, and admitted directly through the Emergency Department from their place of residence. Primary outcomes will be cumulative ambulation score (from day 1 to 3 postoperatively) and cumulative dynamic pain scores (day 1 to 3 postoperatively). Secondary outcomes will be cumulative dynamic pain score preoperatively, cumulative side effects, cumulative calorific and protein intake, EUROQOL EQ-5D score, length of stay, and rehabilitation outcome (measured by mobility score). Discussion Many studies have shown the effectiveness of regional blockade in neck of femur fractures, but the techniques used have varied. This study aims to identify whether early and continuous femoral nerve block can be effective in relieving pain and enhancing mobilization

  14. [Trochanteric femoral fractures: anatomy, biomechanics and choice of implants].

    PubMed

    Bonnaire, F; Lein, T; Bula, P

    2011-06-01

    The objective of any surgical care of a trochanteric femoral fracture should be the achievement of a stable osteosynthesis that allows early full weight-bearing mobilisation of the patient, because long-term immobilisation soon becomes a vital threat to the affected patients who are usually elderly with correlating comorbidities. The anatomical references of the proximal femur and the structure of the hip joint contain some specifics that play an essential role in the incurrence of a trochanteric femoral fracture and the planning of the osteosynthesis as well. With reposition and fracture stabilisation particular importance must be attached to the collo-diaphyseal and the antetorsion angle so that they do not interfere with the functional interaction of the hip and knee joint. Uncomplex trochanteric fractures ordinarily stabilise sufficiently after reposition so that even an extramedullary implant can ensure full weight-bearing stability. With evermore distal fracture course and intertrochanteric comminution zone, rotational instability and pivot transfer of the fracture area to lateral and caudal are followed by an increase of the dislocating forces. These kinds of fractures (A2 and A3 according to the AO/ASIF classification) profit from an intramedullary and rotationally stable osteosynthesis. Basically primary total hip arthroplasty is a potential option for surgical care of a trochanteric fracture in elderly patients with relevant coxarthrosis. However this procedure can only be recommended in cases of a stable uncomplex fracture. The more the medial interlocking of the proximal femur is destroyed the more difficult it will be to primarily implant a total hip prosthesis with good offset and without a varus and rotational failure in the fracture zone.The current studies in the main show disadvantages due to increased complications in these patients, so that in cases of an unstable trochanteric fracture a primary osteosynthesis should be performed followed by

  15. Risk of refracture through unicameral bone cysts of the proximal femur.

    PubMed

    Norman-Taylor, Fabian H; Hashemi-Nejad, Aresh; Gillingham, Bruce L; Stevens, David; Cole, William G

    2002-01-01

    The authors determined the results after traction or traction and hip spica treatment of the initial fractures through unicameral bone cysts of the proximal femur in 20 children. All of the eight displaced fractures healed, but with coxa vara and avascular necrosis in one, coxa vara in a second, and coxa breva in a third. Spontaneous healing of the cyst occurred in three of the eight children; satisfactory healing was achieved and maintained after intralesional corticosteroid injections in four of the eight children. In the remaining child with a displaced fracture, reactivation of the cyst and exercise-related pain, indicative of an incipient refracture, occurred 3 years after initial presentation. All of the 12 undisplaced fractures healed without deformity or avascular necrosis. Intralesional corticosteroids were used in all of the 12 children because none of them showed spontaneous healing of their cysts. Satisfactory radiographic healing was achieved 1 year after presentation in all of the 12 children. However, one or more refractures resulting from reactivation of the cyst occurred in 6 of the 12 children 2 to 5 years after initial presentation. The results of this study indicate that satisfactory radiographic healing needs to be achieved by the end of the first year and needs to be maintained thereafter to prevent refractures.

  16. Combined spinal epidural anesthesia in achondroplastic dwarf for femur surgery

    PubMed Central

    Bakhshi, Rochana Girish; Jagtap, Sheetal R.

    2011-01-01

    Achondroplasia is the commonest form of short-limbed dwarfism and occurs in 1:26,000-40,000 live births. This is an autosomal dominant disorder with abnormal endochondral ossification whereas periosteal and intramembranous ossification are normal. The basic abnormality is a disturbance of cartilage formation mainly at the epiphyseal growth plates and at the base of the skull. The anesthetic management of achondroplastic dwarfs is a challenge to the anesthesiologist. Both regional as well as general anesthesia have their individual risks and consequences. We report a case of an achondroplastic dwarf in whom combined spinal epidural anesthesia was used for fixation of a fractured femur. The patient had undergone previous femur surgery under general anesthesia since he had been informed that spinal anesthesia could be very problematic. There was no technical difficulty encountered during the procedure and an adequate level was achieved with low-dose local anesthetics without any problem. Postoperative pain relief was offered for three consecutive postoperative days using epidural tramadol. We discuss the anesthetic issues and highlight the role of combined spinal epidural anesthesia with low-dose local anesthetics in this patient. This approach also helped in early ambulation and postoperative pain relief. PMID:24765361

  17. Osteomalacia: a forgotten cause of fractures in the elderly

    PubMed Central

    Rokan, Z; Kealey, W D

    2015-01-01

    We present a case of a man who suffered bilateral neck of femur fractures secondary to osteomalacia, attributable to a combination of his reclusive lifestyle, poor diet and long-term anticonvulsant therapy. These fractures may have been prevented if certain risk factors had been identified early. This case aims to highlight the importance of identifying vulnerable older adults in the community who are at risk of fragility fractures secondary to osteomalacia. It should be recognised that not only osteoporosis but other factors can precipitate these fractures as well and that preventative measures should be undertaken in those individuals at risk. PMID:25666245

  18. Fracture epidemiology and control in a developmental center.

    PubMed Central

    Lohiya, G S; Crinella, F M; Tan-Figueroa, L; Caires, S; Lohiya, S

    1999-01-01

    During 3.5 years, 182 fractures occurred among 994 residents of a developmental center. The fracture rate was 5.2 per 100 person-years (1.7 times greater than the rate in the US population). Fracture rate was significantly greater in residents with: epilepsy, older age, male gender, white race, independent ambulation, osteoporosis, and residence in intermediate care (versus skilled nursing) units; it was not affected by severity of mental retardation. Hand and foot bones were fractured in 58% of cases. Femur fracture occurred in 13 cases (7%). Fracture was caused by a fall in 41 cases (23%); its cause was indeterminable in 105 cases (58%). Fractures, occurring without significant injury, may be an important cause of preventable disability in this population. Control measures are suggested. Images Figure 1. Figure 2. PMID:10344173

  19. [Periprosthetic knee fractures].

    PubMed

    Mittlmeier, T; Beck, M; Bosch, U; Wichelhaus, A

    2016-01-01

    The cumulative incidence of periprosthetic fractures around the knee is increasing further because of an extended indication for knee replacement, previous revision arthroplasty, rising life expectancy and comorbidities. The relevance of local parameters such as malalignment, osseous defects, neighbouring implants, aseptic loosening and low-grade infections may sometimes be hidden behind the manifestation of a traumatic fracture. A differentiated diagnostic approach before the treatment of a periprosthetic fracture is of paramount importance, while the physician in-charge should also have particular expertise in fracture treatment and in advanced techniques of revision endoprosthetics. The following work gives an overview of this topic. Valid classifications are available for categorising periprosthetic fractures of the femur, the tibia and the patella respectively, which are helpful for the selection of treatment. With the wide-ranging modern treatment portfolio bearing in mind the substantial rate of complications and the heterogeneous functional outcome, the adequate analysis of fracture aetiology and the corresponding transformation into an individualised treatment concept offer the chance of an acceptable functional restoration of the patient at early full weight-bearing and prolonged implant survival. The management of complications is crucial to the final outcome.

  20. Longitudinal elastic properties and porosity of cortical bone tissue vary with age in human proximal femur.

    PubMed

    Malo, M K H; Rohrbach, D; Isaksson, H; Töyräs, J; Jurvelin, J S; Tamminen, I S; Kröger, H; Raum, K

    2013-04-01

    Tissue level structural and mechanical properties are important determinants of bone strength. As an individual ages, microstructural changes occur in bone, e.g., trabeculae and cortex become thinner and porosity increases. However, it is not known how the elastic properties of bone change during aging. Bone tissue may lose its elasticity and become more brittle and prone to fractures as it ages. In the present study the age-dependent variation in the spatial distributions of microstructural and microelastic properties of the human femoral neck and shaft were evaluated by using acoustic microscopy. Although these properties may not be directly measured in vivo, there is a major interest to investigate their relationships with the linear elastic measurements obtained by diagnostic ultrasound at the most severe fracture sites, e.g., the femoral neck. However, before the validity of novel in vivo techniques can be established, it is essential to understand the age-dependent variation in tissue elastic properties and porosity at different skeletal sites. A total of 42 transverse cross-sectional bone samples were obtained from the femoral neck (Fn) and proximal femoral shaft (Ps) of 21 men (mean±SD age 47.1±17.8, range 17-82years). Samples were quantitatively imaged using a scanning acoustic microscope (SAM) equipped with a 50MHz ultrasound transducer. Distributions of the elastic coefficient (c33) of cortical (Ct) and trabecular (Tr) tissues and microstructure of cortex (cortical thickness Ct.Th and porosity Ct.Po) were determined. Variations in c33 were observed with respect to tissue type (c33Trc33(Ct.Fn)=35.3GPa>c33(Tr.Ps)=33.8GPa>c33(Tr.Fn)=31.9GPa), and cadaver age (R(2)=0.28-0.46, p<0.05). Regional variations in porosity were found in the neck (superior 13.1%; inferior 6.1%; anterior 10.1%; posterior 8.6%) and in the shaft (medial 9.5%; lateral 7.7%; anterior 8.6%; posterior 12.0%). In conclusion, significant variations in

  1. Comminuted supracondylar femoral fractures: a biomechanical analysis comparing the stability of medial versus lateral plating in axial loading.

    PubMed

    Briffa, Nikolai; Karthickeyan, Raju; Jacob, Joshua; Khaleel, Arshad

    2016-11-01

    The aim of this study was to compare the biomechanical properties of medial and lateral plating of a medially comminuted supracondylar femoral fracture. A supracondylar femoral fracture model comparing two fixation methods was tested cyclically in axial loading. One-centimetre supracondylar gap osteotomies were created in six synthetic femurs approximately 6 cm proximal to the knee joint. There were two constructs investigated: group 1 and group 2 were stabilized with an 8-hole LC-DCP, medially and laterally, respectively. Both construct groups were axially loaded. Global displacement (total length), wedge displacement, bending moment and strain were measured. Medial plating showed a significantly decreased displacement, bending moment and strain at the fracture site in axial loading. Medial plating of a comminuted supracondylar femur fracture is more stable than lateral plating.

  2. Ultrasound Diagnosis of Penile Fracture.

    PubMed

    Nizamani, Waseem Mehmood; Ali, Syed Imtiaz; Vaswani, Aneel Kumar; Shahani, Bhesham Kumar

    2015-10-01

    A rare but possibly underreported urological emergency is penile fracture which results from tear in the tunica albuginea of the penis. The proposed etiology is forceful manipulation of an erect penis or secondary to blunt trauma. We would like to report a case of young patient presenting with large penile shaft hematoma and deformity. The patient did not provide obvious history of trauma or sexual intercourse. The ultrasound of penis was performed which suggested the diagnosis of penile fracture and ultrasound findings were correlated with peroperative findings.

  3. Locally applied simvastatin improves fracture healing at late period in osteoporotic rat

    NASA Astrophysics Data System (ADS)

    Tian, Faming; Zhang, Liu; Kang, Yuchuan; Zhang, Junshan; Ao, Jiao; Yang, Fang

    effect of simvastatin locally applied from a bioactive polymer coating of implants on osteoporotic fracture healing at late period. Methods:Femur fracture model was established on normal or osteotoporotic mature female SD rats, intramedullary stabilization was achieved with uncoated titanium Kirschnerwires in normal rats(group A),with polymer-only coated vs. polymer plus simvastatin coated titanium Kirschner wires in osteoporotic rats(group B and C, respectively).Femurs were harvested after 12 weeks, and underwent radiographic and histologic analysis, as well as immunohistochemical evaluation for BMP-2 expression. Results:Radiographic results demonstrated progressed callus in the simvastatin-treated groups compared to the uncoated group.The histologic analysis revealed a significantly processed callus with irregular-shaped newly formed bone trabeculae in simvastatin-treated group. Immunohistochemical evaluation showed markedly higher expression levels of B:MP-2 in simvastatin-treated group.Conclusions: The present study revealed a improved fracture healing under local application of simvastatin in osteoporotic rat,which might partially from upregulation of the B:MP-2 expression at fractured site.

  4. Transverse Stress Fracture of the Proximal Patella: A Case Report.

    PubMed

    Atsumi, Satoru; Arai, Yuji; Kato, Ko; Nishimura, Akinobu; Nakazora, Shigeto; Nakagawa, Shuji; Ikoma, Kazuya; Fujiwara, Hiroyoshi; Sudo, Akihiro; Kubo, Toshikazu

    2016-02-01

    Among stress fractures associated with sports activities, patellar stress fracture is rare. Regarding patella stress fractures, so far only distal transverse or lateral longitudinal fractures have been reported, but there are no reports of transverse fractures occurring in the proximal patella. We describe an extremely rare case of transverse stress fracture of proximal patella in a 9-year-old athlete.A 9-year old boy, who participated in sports (sprints and Kendo) presented with left knee pain without any external injury. In plain radiographs, a fracture line was observed in the proximal 1/3 of the left patella, and a patella stress fracture was diagnosed. For treatment, because 7 months of conservative therapy showed no improvement, internal fixation was carried out using Acutrak screws, and bone union was thus achieved. Three months after the operation, he was able to return to his previous level of athletic sports activity.Regarding the mechanism of onset, it is believed that the causes are longitudinal traction force and patellofemoral contact pressure. On the other hand, the contact region of the patella with the femur changes with the flexion angle of the knee. In the current case, the fracture occurred at a site where the patella was in contact with the femur at a flexion angle of >90°, so it is believed that it occurred as a clinical condition from being subjected to repeated longitudinal traction force and patellofemoral contact pressure at a flexion angle of >90°, during the sports activities of sprints and Kendo. The nonunion of the transverse stress fracture of his proximal patella was successfully treated with internal fixation using Acutrak screws.

  5. Minimal impact of a care pathway for geriatric hip fracture patients.

    PubMed

    Panella, Massimiliano; Seys, Deborah; Sermeus, Walter; Bruyneel, Luk; Lodewijckx, Cathy; Deneckere, Svin; Sermon, An; Nijs, Stefaan; Boto, Paulo; Vanhaecht, Kris

    2018-06-04

    Adherence to guidelines for patients with proximal femur fracture is suboptimal. To evaluate the effect of a care pathway for the in-hospital management of older geriatric hip fracture patients on adherence to guidelines and patient outcomes. The European Quality of Care Pathways study is a cluster randomized controlled trial. 26 hospitals in Belgium, Italy and Portugal. Older adults with a proximal femur fracture (n = 514 patients) were included. Hospitals treating older adults (>65) with a proximal femur fracture were randomly assigned to an intervention group, i.e. implementation of a care pathway, or control group, i.e. usual care. Thirteen patient outcomes and 24 process indicators regarding in-hospital management, as well as three not-recommended care activities were measured. Adjusted and unadjusted regression analyses were conducted using intention-to-treat procedures. In the intervention group 301 patients in 15 hospitals were included, and in the control group 213 patients in 11 hospitals. Sixty-five percent of the patients were older than 80 years. The implementation of this care pathway had no significant impact on the thirteen patient outcomes. The preoperative management improved significantly. Eighteen of 24 process indicators improved, but only two improved significantly. Only for a few teams a geriatrician was an integral member of the treatment team. Implementation of a care pathway improved compliance to evidence, but no significant effect on patient outcomes was found. The impact of the collaboration between surgeons and geriatricians on adherence to guidelines and patient outcomes should be studied. ClinicalTrials.gov: NCT00962910. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Circumferential shaft seal

    NASA Technical Reports Server (NTRS)

    Ludwig, L. P. (Inventor)

    1981-01-01

    A circumferential shaft seal comprising two sealing rings held to a rotating shaft by means of a surrounding elastomeric band is disclosed. The rings are segmented and are of a rigid sealing material such as carbon or a polyimide and graphite fiber composite.

  7. Crank shaft support assembly

    DOEpatents

    Natkin, Robert J.; Oltmans, Bret; Allison, John E.; Heater, Thomas J.; Hines, Joy Adair; Tappen, Grant K.; Peiskammer, Dietmar

    2007-10-23

    A crank shaft support assembly for increasing stiffness and reducing thermal mismatch distortion in a crank shaft bore of an engine comprising different materials. A cylinder block comprises a first material and at least two crank journal inserts are insert-molded into respective crank journal regions of the cylinder block and comprise a second material having greater stiffness and a lower thermal coefficient of expansion that the first material. At least two bearing caps are bolted to the respective crank journal inserts and define, along with the crank journal inserts, at least two crank shaft support rings defining a crank shaft bore coaxially aligned with a crank shaft axis. The bearing caps comprise a material having higher stiffness and a lower thermal coefficient of expansion than the first material and are supported on the respective crank journal inserts independently of any direct connection to the cylinder block.

  8. Circumferential shaft seal

    NASA Technical Reports Server (NTRS)

    Ludwig, L. P. (Inventor)

    1980-01-01

    A circumferential shaft seal is described which comprises two sealing rings held to a rotating shaft by means of a surrounding elastomeric band. The rings are segmented and are of a rigid sealing material such as carbon or a polyimide and graphite fiber composite.

  9. Elastic interactions between single microcrack and single osteon microstructure of human femur cortical bone

    NASA Astrophysics Data System (ADS)

    Mansor, N. N.; Daud, R.; Basaruddin, K. S.; Mat, F.; Bajuri, Y.; Ariffin, A. K.

    2017-09-01

    Inmultiscale Haversian system of cortical bone fracture, a homogenous bone modeling consideration is limited to only one Young modulus was significant for each cortex without having any constituents in that bone. A two dimension model of human femur cortical bone is presented by considering the anatomical positions of four cortices, e.g anterior, posterior, medial and lateral. The Haversian system is modeled under tensile loading by considering the interstitial matrix, osteon and cement line mechanical properties. The interaction between single microcrack and single osteon is evaluated using linear elastic fracture mechanics theory, and was determined using of stress intensity factor, strain energy release rate, and the critical stress intensity factor and critical strain energy release rate parameter. The results indicate that the medial cortex has the highest SIFs while the lowest was posterior cortex. The Young modulus of material was greatly influence the fracture parameters. More stiff the material, the SIF was reduced.

  10. Active shape modeling of the hip in the prediction of incident hip fracture.

    PubMed

    Baker-LePain, Julie C; Luker, Kali R; Lynch, John A; Parimi, Neeta; Nevitt, Michael C; Lane, Nancy E

    2011-03-01

    The objective of this study was to evaluate right proximal femur shape as a risk factor for incident hip fracture using active shape modeling (ASM). A nested case-control study of white women 65 years of age and older enrolled in the Study of Osteoporotic Fractures (SOF) was performed. Subjects (n = 168) were randomly selected from study participants who experienced hip fracture during the follow-up period (mean 8.3 years). Controls (n = 231) had no fracture during follow-up. Subjects with baseline radiographic hip osteoarthritis were excluded. ASM of digitized right hip radiographs generated 10 independent modes of variation in proximal femur shape that together accounted for 95% of the variance in proximal femur shape. The association of ASM modes with incident hip fracture was analyzed by logistic regression. Together, the 10 ASM modes demonstrated good discrimination of incident hip fracture. In models controlling for age and body mass index (BMI), the area under receiver operating characteristic (AUROC) curve for hip shape was 0.813, 95% confidence interval (CI) 0.771-0.854 compared with models containing femoral neck bone mineral density (AUROC = 0.675, 95% CI 0.620-0.730), intertrochanteric bone mineral density (AUROC = 0.645, 95% CI 0.589-0.701), femoral neck length (AUROC = 0.631, 95% CI 0.573-0.690), or femoral neck width (AUROC = 0.633, 95% CI 0.574-0.691). The accuracy of fracture discrimination was improved by combining ASM modes with femoral neck bone mineral density (AUROC = 0.835, 95% CI 0.795-0.875) or with intertrochanteric bone mineral density (AUROC = 0.834, 95% CI 0.794-0.875). Hips with positive standard deviations of ASM mode 4 had the highest risk of incident hip fracture (odds ratio = 2.48, 95% CI 1.68-3.31, p < .001). We conclude that variations in the relative size of the femoral head and neck are important determinants of incident hip fracture. The addition of hip shape to fracture-prediction tools may improve the risk

  11. Callus features of regenerate fracture cases in femoral lengthening in achondroplasia.

    PubMed

    Devmurari, Kamlesh N; Song, Hae Ryong; Modi, Hitesh N; Venkatesh, K P; Ju, Kim Seung; Song, Sang Heon

    2010-09-01

    We studied the callus features seen in cases of regenerate fracture in femoral lengthening using a monolateral fixator in achondroplasia to determine whether callus types and shapes can predict the probability of callus fracture. The radiographs of 28 cases of femoral lengthening in 14 patients, 14 cases of callus fracture, and 14 cases without callus fracture were retrospectively analyzed by four observers and classified into different shapes and types in concordance with the Ru Li classification. The average lengthening of 9.4 cm (range 7.5-11.8 cm) was achieved, which was 41% (range 30-55%) of the original length and the average timing of callus fracture was 470 days (range 440-545 days) after surgery in the callus fracture group. While the average lengthening of 9.1 cm (range 8-9.7 cm) was achieved, this was 30% (range 28-32%) of the original length in the group of patients without callus fracture. The callus was atypically shaped, there was a 48% average (range 30-72%) reduction of the callus width compared with the natural width of the femur, and a lucent pathway was present in all cases of regenerate fracture. A lucent pathway was seen in all fracture cases with concave, lateral, and atypical shapes, and there was more than 30% lengthening and 30% reduction of the callus width compared with the natural width of the femur, which are the warning signs for regenerate fractures. These signs help the surgeon to predict the outcome and guide him in planning for any additional interventions. The Ru Li classification is an effective method for the evaluation of the chance of callus fracture.

  12. Change in fracture risk and fracture pattern after bariatric surgery: nested case-control study.

    PubMed

    Rousseau, Catherine; Jean, Sonia; Gamache, Philippe; Lebel, Stéfane; Mac-Way, Fabrice; Biertho, Laurent; Michou, Laëtitia; Gagnon, Claudia

    2016-07-27

     To investigate whether bariatric surgery increases the risk of fracture.  Retrospective nested case-control study.  Patients who underwent bariatric surgery in the province of Quebec, Canada, between 2001 and 2014, selected using healthcare administrative databases.  12 676 patients who underwent bariatric surgery, age and sex matched with 38 028 obese and 126 760 non-obese controls.  Incidence and sites of fracture in patients who had undergone bariatric surgery compared with obese and non-obese controls. Fracture risk was also compared before and after surgery (index date) within each group and by type of surgery from 2006 to 2014. Multivariate conditional Poisson regression models were adjusted for fracture history, number of comorbidities, sociomaterial deprivation, and area of residence.  Before surgery, patients undergoing bariatric surgery (9169 (72.3%) women; mean age 42 (SD 11) years) were more likely to fracture (1326; 10.5%) than were obese (3065; 8.1%) or non-obese (8329; 6.6%) controls. A mean of 4.4 years after surgery, bariatric patients were more susceptible to fracture (514; 4.1%) than were obese (1013; 2.7%) and non-obese (3008; 2.4%) controls. Postoperative adjusted fracture risk was higher in the bariatric group than in the obese (relative risk 1.38, 95% confidence interval 1.23 to 1.55) and non-obese (1.44, 1.29 to 1.59) groups. Before surgery, the risk of distal lower limb fracture was higher, upper limb fracture risk was lower, and risk of clinical spine, hip, femur, or pelvic fractures was similar in the bariatric and obese groups compared with the non-obese group. After surgery, risk of distal lower limb fracture decreased (relative risk 0.66, 0.56 to 0.78), whereas risk of upper limb (1.64, 1.40 to 1.93), clinical spine (1.78, 1.08 to 2.93), pelvic, hip, or femur (2.52, 1.78 to 3.59) fractures increased. The increase in risk of fracture reached significance only for biliopancreatic diversion.  Patients undergoing bariatric

  13. Osteomalacia: a forgotten cause of fractures in the elderly.

    PubMed

    Rokan, Z; Kealey, W D

    2015-02-09

    We present a case of a man who suffered bilateral neck of femur fractures secondary to osteomalacia, attributable to a combination of his reclusive lifestyle, poor diet and long-term anticonvulsant therapy. These fractures may have been prevented if certain risk factors had been identified early. This case aims to highlight the importance of identifying vulnerable older adults in the community who are at risk of fragility fractures secondary to osteomalacia. It should be recognised that not only osteoporosis but other factors can precipitate these fractures as well and that preventative measures should be undertaken in those individuals at risk. 2015 BMJ Publishing Group Ltd.

  14. Epidemiology of fractures in people with severe and profound developmental disabilities

    USGS Publications Warehouse

    Glick, N.R.; Fischer, M.H.; Heisey, D.M.; Leverson, G.E.; Mann, D.C.

    2005-01-01

    Fractures are more prevalent among people with severe and profound developmental disabilities than in the general population. In order to characterize the tendency of these people to fracture, and to identify features that may guide the development of preventive strategies, we analyzed fracture epidemiology in people with severe and profound developmental disabilities who lived in a stable environment. Data from a 23-year longitudinal cohort registry of 1434 people with severe and profound developmental disabilities were analyzed to determine the effects of age, gender, mobility, bone fractured, month of fracture, and fracture history upon fracture rates. Eighty-five percent of all fractures involved the extremities. The overall fracture rate increased as mobility increased. In contrast, femoral shaft fracture risk was substantially higher in the least mobile [relative risk (RR), 10.36; 95% confidence interval (CI), 3.29-32.66] compared with the most mobile group. Although the overall fracture rate was not associated with age, the femoral shaft fractures decreased but hand/foot fractures increased with age. Overall fracture risk declined in August and September (RR, 0.70; 95% CI, 0.55-0.89), being especially prominent for tibial/fibular fractures (RR, 0.31; 95% CI, 0.13-0.70). Gender was not a factor in fracture risk. Two primary fracture mechanisms are apparent: one, largely associated with lack of weight-bearing in people with the least mobility, is exemplified by femoral fractures during non-traumatic events as simple as diapering or transfers; the other, probably due to movement- or fall-related trauma, is exemplified by hand/foot fractures in people who ambulate. The fracture experience of people with severe and profound developmental disabilities is unique and, because it differs qualitatively from postmenopausal osteoporosis, may require population-specific methods for assessing risk, for improving bone integrity, and for reduction of falls and accidents

  15. Comparison of femoral strength and fracture risk index derived from DXA-based finite element analysis for stratifying hip fracture risk: A cross-sectional study.

    PubMed

    Yang, Shuman; Luo, Yunhua; Yang, Lang; Dall'Ara, Enrico; Eastell, Richard; Goertzen, Andrew L; McCloskey, Eugene V; Leslie, William D; Lix, Lisa M

    2018-05-01

    Dual-energy X-ray absorptiometry (DXA)-based finite element analysis (FEA) has been studied for assessment of hip fracture risk. Femoral strength (FS) is the maximum force that the femur can sustain before its weakest region reaches the yielding limit. Fracture risk index (FRI), which also considers subject-specific impact force, is defined as the ratio of von Mises stress induced by a sideways fall to the bone yield stress over the proximal femur. We compared risk stratification for prior hip fracture using FS and FRI derived from DXA-based FEA. The study cohort included women aged ≥65years undergoing baseline hip DXA, with femoral neck T-scores <-1 and no osteoporosis treatment; 324 cases had prior hip fracture and 655 controls had no prior fracture. Using anonymized DXA hip scans, we measured FS and FRI. Separate multivariable logistic regression models were used to estimate odds ratios (ORs), c-statistics and their 95% confidence intervals (95% CIs) for the association of hip fracture with FS and FRI. Increased hip fracture risk was associated with lower FS (OR per SD 1.36, 95% CI: 1.15, 1.62) and higher FRI (OR per SD 1.99, 95% CI: 1.63, 2.43) after adjusting for Fracture Risk Assessment Tool (FRAX) hip fracture probability computed with bone mineral density (BMD). The c-statistic for the model containing FS (0.69; 95% CI: 0.65, 0.72) was lower than the c-statistic for the model with FRI (0.77; 95% CI: 0.74, 0.80) or femoral neck BMD (0.74; 95% CI: 0.71, 0.77; all P<0.05). FS and FRI were independently associated with hip fracture, but there were differences in performance characteristics. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. Incidence patterns of pediatric and adolescent orthopaedic fractures according to age groups and seasons in South Korea: a population-based study.

    PubMed

    Park, Moon Seok; Chung, Chin Youb; Choi, In Ho; Kim, Tae Won; Sung, Ki Hyuk; Lee, Seung Yeol; Lee, Sang Hyeong; Kwon, Dae Gyu; Park, Jung Woo; Kim, Tae Gyun; Choi, Young; Cho, Tae-Joon; Yoo, Won Joon; Lee, Kyoung Min

    2013-09-01

    Fractures which need urgent or emergency treatment are common in children and adolescents. This study investigated the incidence patterns of pediatric and adolescent orthopaedic fractures according to age groups and seasons in South Korea based on population data. Data on the number of pediatric and adolescent patients under the age of 18 years who utilized medical services due to fractures were retrieved from the Health Insurance Review and Assessment service in South Korea. The data included four upper extremity and two lower extremity fractures according to four age groups (0-4 years, 5-9 years, 10-14 years, and 15-18 years). Incidences of the fractures were calculated as the incidence per 10,000 per year, and patterns according to age groups and seasons were demonstrated. The annual incidence of clavicle, distal humerus, both forearm bone, distal radius, femoral shaft and tibial shaft fractures were 27.5, 34.6, 7.7, 80.1, 2.5, and 9.6 per 10,000 per year in children and adolescents, respectively. Clavicle and distal radius fractures showed significant seasonal variation for all age groups but femoral shaft fracture showed no significant seasonal variation for any of the age groups. The four upper extremity fractures tended to show greater variations than the two lower extremity fractures in the nationwide database in South Korea. The study results are believed to be helpful in the planning and assignment of medical resources for fracture management in children and adolescents.

  17. Biomechanical analysis of a new carbon fiber/flax/epoxy bone fracture plate shows less stress shielding compared to a standard clinical metal plate.

    PubMed

    Bagheri, Zahra S; Tavakkoli Avval, Pouria; Bougherara, Habiba; Aziz, Mina S R; Schemitsch, Emil H; Zdero, Radovan

    2014-09-01

    Femur fracture at the tip of a total hip replacement (THR), commonly known as Vancouver B1 fracture, is mainly treated using rigid metallic bone plates which may result in "stress shielding" leading to bone resorption and implant loosening. To minimize stress shielding, a new carbon fiber (CF)/Flax/Epoxy composite plate has been developed and biomechanically compared to a standard clinical metal plate. For fatigue tests, experiments were done using six artificial femurs cyclically loaded through the femoral head in axial compression for four stages: Stage 1 (intact), stage 2 (after THR insertion), stage 3 (after plate fixation of a simulated Vancouver B1 femoral midshaft fracture gap), and stage 4 (after fracture gap healing). For fracture fixation, one group was fitted with the new CF/Flax/Epoxy plate (n = 3), whereas another group was repaired with a standard clinical metal plate (Zimmer, Warsaw, IN) (n = 3). In addition to axial stiffness measurements, infrared thermography technique was used to capture the femur and plate surface stresses during the testing. Moreover, finite element analysis (FEA) was performed to evaluate the composite plate's axial stiffness and surface stress field. Experimental results showed that the CF/Flax/Epoxy plated femur had comparable axial stiffness (fractured = 645 ± 67 N/mm; healed = 1731 ± 109 N/mm) to the metal-plated femur (fractured = 658 ± 69 N/mm; healed = 1751 ± 39 N/mm) (p = 1.00). However, the bone beneath the CF/Flax/Epoxy plate was the only area that had a significantly higher average surface stress (fractured = 2.10 ± 0.66 MPa; healed = 1.89 ± 0.39 MPa) compared to bone beneath the metal plate (fractured = 1.18 ± 0.93 MPa; healed = 0.71 ± 0.24 MPa) (p < 0.05). FEA bone surface stresses yielded peak of 13 MPa at distal epiphysis (stage 1), 16 MPa at distal epiphysis (stage 2), 85 MPa for composite and 129

  18. Short-term effect of zoledronic acid upon fracture resistance of the mandibular condyle and femoral head in an animal model

    PubMed Central

    López-Jornet, Pía; Vicente-Hernández, Ascensión

    2013-01-01

    Objective: The aim of this study was to compare the effects in terms of resistance to fracture of the mandibular condyle and femoral head following different doses of zoledronic acid in an animal model. Study design: A total of 80 adult male Sprague-Dawley rats were included in a prospective randomized study. The animals were randomly divided into four groups of 20 rats each. Group 1 (control) received sterile saline solution, while groups 2, 3 and 4 received a accumulated dose of 0.2 mg, 0.4 mg and 0.6 mg of zoledronic acid, respectively. The animals were sacrificed 28 days after the last dose, and the right hemimandible and the right femur were removed. The fracture strength was measured (in Newtons) with a universal test machine using a 1 kN load connected to a metal rod with one end angled at 30 degrees. The cross-head speed was 1 mm/min. Later, the specimens were observed under a scanning electron microscope with backscattered electron imaging (SEM-BSE). At last, chemical analysis and elemental mapping of the mineral bone composition were generated using a microanalytical system based on energy-dispersive and X-ray spectrometry (EDX). Results: A total of 160 fracture tests were performed. The fracture resistance increased in mandible and femur with a higher accumulated dose of zoledronic acid. Statistically significant differences were recorded versus the controls with all the studies groups. The chemical analysis in mandible showed a significantly increased of calcium and phosphorous to compare the control with all of the study groups; however, in femur no statistically significant differences between the four study groups were observed. Conclusions: The administration of bisphosphonates increases the fracture resistance in mandible and femur. Key words:Zoledronic acid, bisphosphonates, animal experimentation, fracture test. PMID:23524420

  19. Differentiating Stress Fracture From Periostitis.

    PubMed

    Martire, J R

    1994-10-01

    In brief Even in the age of high-technology MRI and CT, the triple-phase bone scan (TPBS) remains an exceptionally useful and accurate tool in evaluating athletic injuries. This is perhaps best seen in active people with overuse injuries of the tibia, femur, or humerus when plain films are negative but bone pain persists. Differentiating periostitis from stress fracture requires analyzing distinctive TPBS appearances and patterns.

  20. Potential relationship between design of nickel-titanium rotary instruments and vertical root fracture.

    PubMed

    Kim, Hyeon-Cheol; Lee, Min-Ho; Yum, Jiwan; Versluis, Antheunis; Lee, Chan-Joo; Kim, Byung-Min

    2010-07-01

    Nickel-titanium (NiTi) rotary files can produce cleanly tapered canal shapes with low tendency of transporting the canal lumen. Because NiTi instruments are generally perceived to have high fracture risk during use, new designs have been marketed to lower fracture risks. However, these design variations may also alter the forces on a root during instrumentation and increase dentinal defects that predispose a root to fracture. This study compared the stress conditions during rotary instrumentation in a curved root for three NiTi file designs. Stresses were calculated using finite element (FE) analysis. FE models of ProFile (Dentsply Maillefer, Ballaigues, Switzerland; U-shaped cross-section and constant 6% tapered shaft), ProTaper Universal (Dentsply; convex triangular cross-section with notch and progressive taper shaft), and LightSpeed LSX (Lightspeed Technology, Inc, San Antonio, TX; noncutting round shaft) were rotated within a curved root canal. The stress and strain conditions resulting from the simulated shaping action were evaluated in the apical root dentin. ProTaper Universal induced the highest von Mises stress concentration in the root dentin and had the highest tensile and compressive principal strain components at the external root surface. The calculated stress values from ProTaper Universal, which had the biggest taper shaft, approached the strength properties of dentin. LightSpeed generated the lowest stresses. The stiffer file designs generated higher stress concentrations in the apical root dentin during shaping of the curved canal, which raises the risk of dentinal defects that may lead to apical root cracking. Thus, stress levels during shaping and fracture susceptibility after shaping vary with instrument design. Copyright 2010 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  1. Birth-associated long-bone fractures.

    PubMed

    Basha, Asma; Amarin, Zouhair; Abu-Hassan, Freih

    2013-11-01

    To assess the incidence and outcome of neonatal long-bone fractures at a tertiary teaching hospital. A retrospective study of all neonates with long-bone fractures delivered at Jordan University Hospital between January 1, 2000, and December 31, 2010. Among a total of 34 519 live births, 8 neonates had a long-bone fracture (incidence 0.23/1000 live births); of these, 6 had a femur fracture (0.17/1000 live births) and 2 had a humerus fracture (0.05/1000 live births). The route of delivery was emergency cesarean delivery for 6 infants, elective cesarean delivery for 1 infant, and the vaginal route for 1 infant. The mean birth weight was 2723g. All neonates weighed more than 2200g and their gestational age was more than 35weeks, with the exception of 1 neonate born at 31weeks weighing 1500g. The mean time interval from birth to fracture diagnosis was 1.5days. All fractures healed with no residual deformity. Emergency cesarean delivery carries a higher risk of long-bone fracture than vaginal delivery. Prematurity, malpresentation, abnormal lie, and multiple pregnancies may predispose to long-bone fractures. The prognosis of birth-associated long-bone fractures is good. © 2013.

  2. Assessment of Hip Fracture Risk Using Cross-Section Strain Energy Determined by QCT-Based Finite Element Modeling

    PubMed Central

    Kheirollahi, Hossein

    2015-01-01

    Accurate assessment of hip fracture risk is very important to prevent hip fracture and to monitor the effect of a treatment. A subject-specific QCT-based finite element model was constructed to assess hip fracture risk at the critical locations of femur during the single-leg stance and the sideways fall. The aim of this study was to improve the prediction of hip fracture risk by introducing a novel failure criterion to more accurately describe bone failure mechanism. Hip fracture risk index was defined using cross-section strain energy, which is able to integrate information of stresses, strains, and material properties affecting bone failure. It was found that the femoral neck and the intertrochanteric region have higher fracture risk than other parts of the femur, probably owing to the larger content of cancellous bone in these regions. The study results also suggested that women are more prone to hip fracture than men. The findings in this study have a good agreement with those clinical observations reported in the literature. The proposed hip fracture risk index based on strain energy has the potential of more accurate assessment of hip fracture risk. However, experimental validation should be conducted before its clinical applications. PMID:26601105

  3. The best location for proximal locking screw for femur interlocking nailing: A biomechanical study

    PubMed Central

    Karaarslan, Ahmet A; Karakaşli, Ahmet; Aycan, Hakan; Çeçen, Berivan; Yildiz, Didem Venüs; Sesli, Erhan

    2016-01-01

    Background: Proximal locking screw deformation and screw fracture is a frequently seen problem for femur interlocking nailing that affects fracture healing. We realized that there is lack of literature for the right level for the proximal locking screw. We investigated the difference of locking screw bending resistance between the application of screws on different proximal femoral levels. Materials and Methods: We used a total of 80 proximal locking screws for eight groups, 10 screws for each group. Three-point bending tests were performed on four types of screws in two different trochanteric levels (the lesser trochanter and 20 mm proximal). We determined the yield points at three-point bending tests that a permanent deformation started in the locking screws using an axial compression testing machine. Results: The mean yield point value of 5 mm threaded locking screws applied 20 mm proximal of lesser trochanter was 1022 ± 49 (range 986–1057) (mean ± standard deviation, 95% confidence interval). On the other hand, the mean yield point value of the same type of locking screws applied on the lesser trochanteric level was 2089 ± 249 (range 1911–2268). Which means 103% increase of screw resistance between two levels (P = 0.000). In all screw groups, on the lesser trochanter line we determined 98–174% higher than the yield point values of the same type of locking screws in comparison with 20 mm proximal to the lesser trochanter (P = 0.000). Conclusion: According to our findings, there is twice as much difference in locking screw bending resistance between these two application levels. To avoid proximal locking screw deformation, locking screws should be placed in the level of the lesser trochanter in nailing of 1/3 middle and distal femur fractures. PMID:26955183

  4. Periprosthetic fractures of the humerus.

    PubMed

    McDonough, Edward B; Crosby, Lynn A

    2005-12-01

    Periprosthetic humeral fractures present a treatment challenge for the orthopedic surgeon. The overall incidence of fracture is between 0.5% and 3%, with the majority of fractures occurring intraoperatively and involving the humeral diaphysis. Excess torque produced during surgery is usually responsible for intraoperative fractures. Improper canal preparation or prosthetic placement may also increase the chance of sustaining a fracture. Postoperative fractures are most commonly caused by minor trauma, such as a fall. Poor bone quality, female sex, advanced age, and history of rheumatoid arthritis are the risk factors most commonly associated with periprosthetic fractures. All 4 systems used to describe periprosthetic humeral shaft fractures classify fracture patterns according to the anatomic relation of the fracture to the prosthetic stem. Treatment decisions should be made with respect to obtaining fracture stability, initiating early gleno-humeral motion, and restoring shoulder function. Intraoperative fractures and any postoperative fracture resulting in prosthetic instability should be treated with a long-stem prosthesis extending at least 2 to 3 cortical diameters past the fracture site with consideration for rigid plate fixation. Short oblique or transverse postoperative fractures should be managed with early stable fixation. There has been some support for conservative treatment of long oblique or spiral postoperative fractures. Postoperative diaphyseal fractures distal to the stem generally are well maintained with standard fracture management.

  5. Towards automatic computer-aided knee surgery by innovative methods for processing the femur surface model.

    PubMed

    Cerveri, Pietro; Marchente, Mario; Bartels, Ward; Corten, Kristoff; Simon, Jean-Pierre; Manzotti, Alfonso

    2010-09-01

    The femoral shaft (FDA) and transepicondylar (TA), anterior-posterior (WL) and posterior condylar (PCL) axes are fundamental quantities in planning knee arthroplasty surgery. As an alternative to the TA, we introduce the anatomical flexion axis (AFA). Obtaining such axes from image data without any manual supervision remains a practical objective. We propose a novel method that automatically computes the axes of the distal femur by processing the femur mesh surface. Surface data were processed by exploiting specific geometric, anatomical and functional properties. Robust ellipse fitting of the two-dimensional (2D) condylar profiles was utilized to determine the AFA alternative to the TA. The repeatability of the method was tested upon 20 femur surfaces reconstructed from CT scans taken on cadavers. At the highest surface resolutions, the relative median error in the direction of the FDA, AFA, PCL, WL and TA was < 0.50 degrees, 1.20 degrees, 1.0 degrees, 1.30 degrees and 1.50 degrees, respectively. As expected, at the lowest surface resolution, the repeatability decreased to 1.20 degrees, 2.70 degrees, 3.30 degrees, 3.0 degrees and 4.70 degrees, respectively. The computed directions of the FDA, PCL, WL and TA were in agreement (0.60 degrees, 1.55 degrees, 1.90 degrees, 2.40 degrees) with the corresponding reference parameters manually identified in the original CT images by medical experts and with the literature. The proposed method proved that: (a) the AFA can be robustly computed by a geometrical analysis of the posterior profiles of the two condyles and can be considered a useful alternative to the TA; (b) higher surface resolutions leads to higher repeatability of all computed quantities; (c) the TA is less repeatable than the other axes. Copyright 2010 John Wiley & Sons, Ltd.

  6. Axial and appendicular bone density predict fractures in older women

    NASA Technical Reports Server (NTRS)

    Black, D. M.; Cummings, S. R.; Genant, H. K.; Nevitt, M. C.; Palermo, L.; Browner, W.

    1992-01-01

    To determine whether measurement of hip and spine bone mass by dual-energy x-ray absorptiometry (DEXA) predicts fractures in women and to compare the predictive value of DEXA with that of single-photon absorptiometry (SPA) of appendicular sites, we prospectively studied 8134 nonblack women age 65 years and older who had both DEXA and SPA measurements of bone mass. A total of 208 nonspine fractures, including 37 wrist fractures, occurred during the follow-up period, which averaged 0.7 years. The risk of fracture was inversely related to bone density at all measurement sites. After adjusting for age, the relative risks per decrease of 1 standard deviation in bone density for the occurrence of any fracture was 1.40 for measurement at the proximal femur (95% confidence interval 1.20-1.63) and 1.35 (1.15-1.58) for measurement at the spine. Results were similar for all regions of the proximal femur as well as SPA measurements at the calcaneus, distal radius, and proximal radius. None of these measurements was a significantly better predictor of fractures than the others. Furthermore, measurement of the distal radius was not a better predictor of wrist fracture (relative risk 1.64: 95% CI 1.13-2.37) than other sites, such as the lumbar spine (RR 1.56; CI 1.07-2.26), the femoral neck (RR 1.65; CI 1.12-2.41), or the calcaneus (RR 1.83; CI 1.26-2.64). We conclude that the inverse relationship between bone mass and risk of fracture in older women is similar for absorptiometric measurements made at the hip, spine, and appendicular sites.

  7. Stress fracture of the pelvis and lower limbs including atypical femoral fractures-a review.

    PubMed

    Tins, Bernhard J; Garton, Mark; Cassar-Pullicino, Victor N; Tyrrell, Prudencia N M; Lalam, Radhesh; Singh, Jaspreet

    2015-02-01

    Stress fractures, that is fatigue and insufficiency fractures, of the pelvis and lower limb come in many guises. Most doctors are familiar with typical sacral, tibial or metatarsal stress fractures. However, even common and typical presentations can pose diagnostic difficulties especially early after the onset of clinical symptoms. This article reviews the aetiology and pathophysiology of stress fractures and their reflection in the imaging appearances. The role of varying imaging modalities is laid out and typical findings are demonstrated. Emphasis is given to sometimes less well-appreciated fractures, which might be missed and can have devastating consequences for longer term patient outcomes. In particular, atypical femoral shaft fractures and their relationship to bisphosphonates are discussed. Migrating bone marrow oedema syndrome, transient osteoporosis and spontaneous osteonecrosis are reviewed as manifestations of stress fractures. Radiotherapy-related stress fractures are examined in more detail. An overview of typical sites of stress fractures in the pelvis and lower limbs and their particular clinical relevance concludes this review. Teaching Points • Stress fractures indicate bone fatigue or insufficiency or a combination of these. • Radiographic visibility of stress fractures is delayed by 2 to 3 weeks. • MRI is the most sensitive and specific modality for stress fractures. • Stress fractures are often multiple; the underlying cause should be evaluated. • Infratrochanteric lateral femoral fractures suggest an atypical femoral fracture (AFF); endocrinologist referral is advisable.

  8. Medial submuscular plating of the femur in a series of paediatric patients: a useful alternative to standard lateral techniques.

    PubMed

    Nayagam, S; Davis, B; Thevendran, G; Roche, A J

    2014-01-01

    We describe the technique and results of medial submuscular plating of the femur in paediatric patients and discuss its indications and limitations. Specifically, the technique is used as part of a plate-after-lengthening strategy, where the period of external fixation is reduced and the plate introduced by avoiding direct contact with the lateral entry wounds of the external fixator pins. The technique emphasises that vastus medialis is interposed between the plate and the vascular structures. A total of 16 patients (11 male and five female, mean age 9.6 years (5 to 17)), had medial submuscular plating of the femur. All underwent distraction osteogenesis of the femur with a mean lengthening of 4.99 cm (3.2 to 12) prior to plating. All patients achieved consolidation of the regenerate without deformity. The mean follow-up was 10.5 months (7 to 15) after plating for those with plates still in situ, and 16.3 months (1 to 39) for those who subsequently had their plates removed. None developed a deep infection. In two patients a proximal screw fractured without loss of alignment; one patient sustained a traumatic fracture six months after removal of the plate. Placing the plate on the medial side is advantageous when the external fixator is present on the lateral side, and is biomechanically optimal in the presence of a femoral defect. We conclude that medial femoral submuscular plating is a useful technique for specific indications and can be performed safely with a prior understanding of the regional anatomy.

  9. Individual-specific multi-scale finite element simulation of cortical bone of human proximal femur

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ascenzi, Maria-Grazia, E-mail: mgascenzi@mednet.ucla.edu; Kawas, Neal P., E-mail: nealkawas@ucla.edu; Lutz, Andre, E-mail: andre.lutz@hotmail.de

    2013-07-01

    We present an innovative method to perform multi-scale finite element analyses of the cortical component of the femur using the individual’s (1) computed tomography scan; and (2) a bone specimen obtained in conjunction with orthopedic surgery. The method enables study of micro-structural characteristics regulating strains and stresses under physiological loading conditions. The analysis of the micro-structural scenarios that cause variation of strain and stress is the first step in understanding the elevated strains and stresses in bone tissue, which are indicative of higher likelihood of micro-crack formation in bone, implicated in consequent remodeling or macroscopic bone fracture. Evidence that micro-structuremore » varies with clinical history and contributes in significant, but poorly understood, ways to bone function, motivates the method’s development, as does need for software tools to investigate relationships between macroscopic loading and micro-structure. Three applications – varying region of interest, bone mineral density, and orientation of collagen type I, illustrate the method. We show, in comparison between physiological loading and simple compression of a patient’s femur, that strains computed at the multi-scale model’s micro-level: (i) differ; and (ii) depend on local collagen-apatite orientation and degree of calcification. Our findings confirm the strain concentration role of osteocyte lacunae, important for mechano-transduction. We hypothesize occurrence of micro-crack formation, leading either to remodeling or macroscopic fracture, when the computed strains exceed the elastic range observed in micro-structural testing.« less

  10. Preload Torque Limiting Shaft Coupling

    NASA Technical Reports Server (NTRS)

    Harmening, W. A. (Inventor)

    1975-01-01

    A torque limiting spring for a rotating shaft system which acts bidirectionally and is preloaded is examined. The spring is a split circular ring compressed into cavities on facing surfaces of matching shafts. The spring is preloaded by varying the width of a tang in the shaft cavity relative to the split in the spring.

  11. Aqueous extract of Peperomia pellucida (L.) HBK accelerates fracture healing in Wistar rats.

    PubMed

    Florence, Ngueguim Tsofack; Huguette, Sakouong Talle Suewellyne; Hubert, Donfack Jean; Raceline, Gounoue Kamkumo; Desire, Dzeufiet Djomeni Paul; Pierre, Kamtchouing; Theophile, Dimo

    2017-04-04

    Peperomia pellucida (L.) HBK is consumed as vegetable and used in Cameroonian traditional medicine for the management of diseases and for fracture healing. Therefore the aim of this study was to evaluate the effects of the aqueous whole plant extract of Peperomia pellucida on fracture healing in female Wistar rats. A drill hole injury was created by inserting a drill bit inthe diaphysis of the femur. The aqueous extract of the whole plant of Peperomia pellucida was administered orally at the doses of 100, 200 and 400 mg/kg to adult female Wistar rats. The vehicle (distilled water) was given to the control. Besides these rats, one group of rats without fracture received the extract (400 mg/kg). After 14 days of treatment, the rats were sacrificed under anesthesia and the effects of the extract were evaluated on body weight, the relative weights of organs (femurs, uteri and ovaries) and on hematology. Bone (calcium, phosphorus, alkaline phosphatase) and serum biochemical parameters (calcium, phosphorus, alkaline phosphatase) were also evaluated. Radiological and histological tests were carried out on the femurs. The mineral content of the plant extract was also investigated. The extract induced an increase in body weight at high dose and in WBCs count at low doses. Aqueous extract from Peperomia pellucida increased bone calcium at lowest dose but maintained this parameter at normal range at high dose in fractured rat. Alkaline phophatase and phosphorus concentrations reduced significantly (p < 0.01) at the dose of 400 mg/kg as compared to fractured rats. Moreover, radiological tests revealed a dose dependent formation of callus at the level of the fracture gap, confirmed by the formation of a highly dense and compact fibrocartilagenous callus. The mineral content of the plant extract revealed the presence of calcium, phosphorus, magnesium, sodium and potassium. The aqueous extract of P. pellucida accelerates bone healing due partly to the mineral content of the

  12. Forging Long Shafts On Disks

    NASA Technical Reports Server (NTRS)

    Tilghman, Chris; Askey, William; Hopkins, Steven

    1989-01-01

    Isothermal-forging apparatus produces long shafts integral with disks. Equipment based on modification of conventional isothermal-forging equipment, required stroke cut by more than half. Enables forging of shafts as long as 48 in. (122 cm) on typical modified conventional forging press, otherwise limited to making shafts no longer than 18 in. (46cm). Removable punch, in which forged material cools after plastic deformation, essential novel feature of forging apparatus. Technology used to improve such products as components of gas turbines and turbopumps and of other shaft/disk parts for powerplants, drive trains, or static structures.

  13. Review of literature of radial nerve injuries associated with humeral fractures-an integrated management strategy.

    PubMed

    Li, YuLin; Ning, GuangZhi; Wu, Qiang; Wu, QiuLi; Li, Yan; Feng, ShiQing

    2013-01-01

    Radial nerve palsy associated with fractures of the shaft of the humerus is the most common nerve lesion complicating fractures of long bones. However, the management of radial nerve injuries associated with humeral fractures is debatable. There was no consensus between observation and early exploration. The PubMed, Embase, Cochrane Central Register of Controlled Trials, Google Scholar, CINAHL, International Bibliography of the Social Sciences, and Social Sciences Citation Index were searched. Two authors independently searched for relevant studies in any language from 1966 to Jan 2013. Thirty studies with 2952 humeral fractures participants were identified. Thirteen studies favored conservative strategy. No significant difference between early exploration and no exploration groups (OR, 1.03, 95% CI 0.61, 1.72; I(2) = 0.0%, p = 0.918 n.s.). Three studies recommend early radial nerve exploration in patients with open fractures of humerus with radial nerve injury. Five studies proposed early exploration was performed in high-energy humeral shaft fractures with radial nerve injury. The conservative strategy was a good choice for patients with low-energy closed fractures of humerus with radial nerve injury. We recommend early radial nerve exploration (within the first 2 weeks) in patients with open fractures or high-energy closed fractures of humerus with radial nerve injury.

  14. MULTIPLE SHAFT TOOL HEAD

    DOEpatents

    Colbert, H.P.

    1962-10-23

    An improved tool head arrangement is designed for the automatic expanding of a plurality of ferruled tubes simultaneously. A plurality of output shafts of a multiple spindle drill head are driven in unison by a hydraulic motor. A plurality of tube expanders are respectively coupled to the shafts through individual power train arrangements. The axial or thrust force required for the rolling operation is provided by a double acting hydraulic cylinder having a hollow through shaft with the shaft cooperating with an internally rotatable splined shaft slidably coupled to a coupling rigidly attached to the respectlve output shaft of the drill head, thereby transmitting rotary motion and axial thrust simultaneously to the tube expander. A hydraulic power unit supplies power to each of the double acting cylinders through respective two-position, four-way valves, under control of respective solenoids for each of the cylinders. The solenoids are in turn selectively controlled by a tool selection control unit which in turn is controlled by signals received from a programmed, coded tape from a tape reader. The number of expanders that are extended in a rolling operation, which may be up to 42 expanders, is determined by a predetermined program of operations depending upon the arrangement of the ferruled tubes to be expanded in the tube bundle. The tape reader also supplies dimensional information to a machine tool servo control unit for imparting selected, horizontal and/or vertical movement to the tool head assembly. (AEC)

  15. Hindfoot Valgus following Interlocking Nail Treatment for Tibial Diaphysis Fractures: Can the Fibula Be Neglected?

    PubMed Central

    Uzun, Metin; Kara, Adnan; Adaş, Müjdat; Karslioğlu, Bülent; Bülbül, Murat; Beksaç, Burak

    2014-01-01

    Purpose. We evaluated whether intramedullary nail fixation for tibial diaphysis fractures with concomitant fibula fractures (except at the distal one-third level) managed conservatively with an associated fibula fracture resulted in ankle deformity and assessed the impact of the ankle deformity on lower extremity function. Methods. Sixty middle one-third tibial shaft fractures with associated fibular fractures, except the distal one-third level, were included in this study. All tibial shaft fractures were anatomically reduced and fixed with interlocking intramedullary nails. Fibular fractures were managed conservatively. Hindfoot alignment was assessed clinically. Tibia and fibular lengths were compared to contralateral measurements using radiographs. Functional results were evaluated using the Knee Injury and Osteoarthritis Outcome Score (KOOS) and the Foot and Ankle Disability Index Score (FADI). Results. Anatomic union, defined as equal length in operative and contralateral tibias, was achieved in 60 fractures (100%). Fibular shortening was identified in 42 fractures (68%). Mean fibular shortening was 1.2 cm (range, 0.5–2 cm). Clinical exams showed increased hindfoot valgus in 42 fractures (68%). The mean KOOS was 88.4, and the mean FADI score was 90. Conclusion. Fibular fractures in the middle or proximal one-third may need to be stabilized at the time of tibial intramedullary nail fixation to prevent development of hindfoot valgus due to fibular shortening. PMID:25544899

  16. Minimal internal fixation augmented by small wire transfixion frames for high-energy tibial plateau fractures.

    PubMed

    Katsenis, Dimitris; Athanasiou, Vasilis; Vasilis, Athanasiou; Megas, Panayiotis; Panayiotis, Megas; Tyllianakis, Minos; Minos, Tillianakis; Lambiris, Elias

    2005-04-01

    To evaluate the outcome of bicondylar tibial plateau fractures treated with minimal internal fixation augmented by small wire external fixation frames and to assess the necessity of bridging the knee joint by extending the external fixation to the distal femur. This is a retrospective study of 48 tibial plateau fractures. There were 40 (83.5%) Schatzker type VI fractures, 8 Schatzker type V fractures, and 18 (37.5%) fractures were open. A complex injury according to the Tscherne-Lobenhoffer classification was recorded in 30 (62.5%) patients. All fractures were treated with combined minimally invasive internal and external fixation. Closed reduction was achieved in 32 (66.6%) of the fractures. Extension of the external fixation to the distal femur was done in 30 (62.5%) fractures. Results were assessed according to the criteria of Honkonen-Jarvinen. Follow-up ranged from 28 to 60 months with an average of 38 months. All fractures but 1 united at an average of 13.5 weeks (range 11-18 weeks). One patient developed an infected nonunion of the diaphyseal segment of his fracture. Thirty-nine (81%) patients achieved an excellent or good radiologic result. An excellent or good final clinical result was recorded in 36 patients (76%). Bridging the knee joint did not affect significantly the result (P < 0.418). No significant correlation was found between the type of fracture and the final score (P < 0.458). Hybrid internal and external fixation combined with tibiofemoral extension of the fixation is an attractive treatment option for complex tibial plateau fractures.

  17. A novel role for cathepsin K in periosteal osteoclast precursors during fracture repair.

    PubMed

    Walia, Bhavita; Lingenheld, Elizabeth; Duong, Le; Sanjay, Archana; Drissi, Hicham

    2018-03-01

    Osteoporosis management is currently centered around bisphosphonates, which inhibit osteoclast (OC) bone resorption but do not affect bone formation. This reduces fracture risk, but fails to restore healthy bone remodeling. Studies in animal models showed that cathepsin K (CatK) inhibition by genetic deletion or chemical inhibitors maintained bone formation while abrogating resorption during bone remodeling and stimulated periosteal bone modeling. Recently, periosteal mononuclear tartrate-resistant acid phosphatase-positive (TRAP + ) osteoclast precursors (OCPs) were shown to augment angiogenesis-coupled osteogenesis. CatK gene deletion increased osteoblast differentiation via enhanced OCP and OC secretion of platelet-derived growth factor (PDGF)-BB and sphingosine 1 phosphate. The effects of periosteum-derived OCPs on bone remodeling are unknown, particularly with regard to fracture repair. We hypothesized that periosteal OCPs derived from CatK-null (Ctsk -/- ) mice may enhance periosteal bone formation during fracture repair. We found fewer periosteal OCPs in Ctsk -/- mice under homeostatic conditions; however, after fracture, this population increased in number relative to that seen in wild-type (WT) mice. Enhanced TRAP staining and greater expression of PDGF-BB were observed in fractured Ctsk -/- femurs relative to WT femurs. This early pattern of augmented PDGF-BB expression in Ctsk -/- mice may contribute to improved fracture healing by enhancing callus mineralization in Ctsk -/- mice. © 2018 New York Academy of Sciences.

  18. Shaft seal assembly and method

    NASA Technical Reports Server (NTRS)

    Keba, John E. (Inventor)

    2007-01-01

    A pressure-actuated shaft seal assembly and associated method for controlling the flow of fluid adjacent a rotatable shaft are provided. The seal assembly includes one or more seal members that can be adjusted between open and closed positions, for example, according to the rotational speed of the shaft. For example, the seal member can be configured to be adjusted according to a radial pressure differential in a fluid that varies with the rotational speed of the shaft. In addition, in the closed position, each seal member can contact a rotatable member connected to the shaft to form a seal with the rotatable member and prevent fluid from flowing through the assembly. Thus, the seal can be closed at low speeds of operation and opened at high speeds of operation, thereby reducing the heat and wear in the seal assembly while maintaining a sufficient seal during all speeds of operation.

  19. Is Total Femur Replacement a Reliable Treatment Option for Patients With Metastatic Carcinoma of the Femur?

    PubMed

    Sevelda, Florian; Waldstein, Wenzel; Panotopoulos, Joannis; Kaider, Alexandra; Funovics, Philipp Theodor; Windhager, Reinhard

    2018-05-01

    The majority of metastatic bone lesions to the femoral bone can be treated without surgery or with minimally invasive intramedullary nailing. In rare patients with extensive metastatic disease to the femur, total femur replacement may be the only surgical alternative to amputation; however, little is known about this approach. In a highly selected small group of patients with metastatic carcinoma of the femur, we asked: (1) What was the patient survivorship after this treatment? (2) What was the implant survivorship free from all-cause revision and amputation, and what complications were associated with this treatment? (3) What functional outcomes were achieved by patients after total femur replacement for this indication? Eleven patients (three men, eight women) with a mean age of 64 years (range, 41-78 years) received total femur replacements between 1986 and 2016; none were lost to followup. The most common primary disease was breast cancer. In general, during this period, our indications for this procedure were extensive metastatic disease precluding internal fixation or isolated proximal or distal femur replacement, and an anticipated lifespan exceeding 6 months. Our contraindication for this procedure during this time was expected lifespan less than 6 months. Patient survival was assessed by Kaplan-Meier analysis; implant survival free from revision surgery and amputation were assessed by competing risk analysis. Function was determined preoperatively and 6 to 12 weeks postoperatively with the Musculoskeletal Tumor Society (MSTS) score normalized to a 100-point scale, with higher scores representing better function from a longitudinally maintained institutional database. Eleven patients died at a median of 5 months (range, 1-31 months) after surgery. One-year revision-free and limb survival were 82% (95% CI, 51%-98%) and 91% (95% CI, 61%-99%), respectively. Reasons for reoperation were hip dislocation, infection and local recurrence in one patient each. The

  20. Noncontact Measurements Of Torques In Shafts

    NASA Technical Reports Server (NTRS)

    Schwartzbart, Aaron

    1991-01-01

    Additional information extracted from eddy-current proximeter. Positioned over rotating shaft, measures both displacement of and torsion in shaft. Torque applied to shaft calculable from output of proximeter. Possible to extract torsion information from existing tape-recorded proximeter data.

  1. The effect of hip positioning on the projected femoral neck-shaft angle: a modeling study.

    PubMed

    Bhashyam, Abhiram R; Rodriguez, Edward K; Appleton, Paul; Wixted, John J

    2018-04-03

    The femoral neck-shaft angle (NSA) is used to restore normal hip geometry during hip fracture repair. Femoral rotation is known to affect NSA measurement, but the effect of hip flexion-extension is unknown. The goals of this study were to determine and test mathematical models of the relationship between hip flexion-extension, femoral rotation and NSA. We hypothesized that hip flexion-extension and femoral rotation would result in NSA measurement error. Two mathematical models were developed to predict NSA in varying degrees of hip flexion-extension and femoral rotation. The predictions of the equations were tested in vitro using a model that varied hip flexion-extension while keeping rotation constant, and vice versa. The NSA was measured from an AP radiograph obtained with a C-arm. Attributable measurement error based on hip positioning was calculated from the models. The predictions of the model correlated well with the experimental data (correlation coefficient = 0.82 - 0.90). A wide range of patient positioning was found to result in less than 5-10 degree error in the measurement of NSA. Hip flexion-extension and femoral rotation had a synergistic effect in measurement error of the NSA. Measurement error was minimized when hip flexion-extension was within 10 degrees of neutral. This study demonstrates that hip flexion-extension and femoral rotation significantly affect the measurement of the NSA. To avoid inadvertently fixing the proximal femur in varus or valgus, the hip should be positioned within 10 degrees of neutral flexion-extension with respect to the C-arm to minimize positional measurement error. N/A, basic science study.

  2. Lower limb stress fractures in sport: Optimising their management and outcome

    PubMed Central

    Robertson, Greg A J; Wood, Alexander M

    2017-01-01

    Stress fractures in sport are becoming increasing more common, comprising up to 10% of all of sporting injuries. Around 90% of such injuries are located in the lower limb. This articles aims to define the optimal management of lower limb stress fractures in the athlete, with a view to maximise return rates and minimise return times to sport. Treatment planning of this condition is specific to the location of the injury. However, there remains a clear division of stress fractures by “high” and “low” risk. “Low risk” stress fractures are those with a low probability of fracture propagation, delayed union, or non-union, and so can be managed reliably with rest and exercise limitation. These include stress fractures of the Postero-Medial Tibial Diaphysis, Metatarsal Shafts, Distal Fibula, Medial Femoral Neck, Femoral Shaft and Calcaneus. “High risk” stress fractures, in contrast, have increased rates of fracture propagation, displacement, delayed and non-union, and so require immediate cessation of activity, with orthopaedic referral, to assess the need for surgical intervention. These include stress fractures of the Anterior Tibial Diaphysis, Fifth Metatarsal Base, Medial Malleolus, Lateral Femoral Neck, Tarsal Navicular and Great Toe Sesamoids. In order to establish the optimal methods for managing these injuries, we present and review the current evidence which guides the treatment of stress fractures in athletes. From this, we note an increased role for surgical management of certain high risk stress fractures to improve return times and rates to sport. Following this, key recommendations are provided for the management of the common stress fracture types seen in the athlete. Five case reports are also presented to illustrate the application of sport-focussed lower limb stress fracture treatment in the clinical setting. PMID:28361017

  3. Hyperacute cerebral fat embolism in a patient with femoral shaft fracture.

    PubMed

    Chen, Po-Chuan; Hsu, Chin-Wang; Liao, Wen-I; Chen, Yu-Long; Ho, Cheng-Hsuan; Tsai, Shih-Hung

    2013-09-01

    Fat embolism syndrome is a potentially fatal complication and occurs most commonly after long bone fracture. In patients who sustained severe trauma, both cerebral fat embolism(CFE) and diffuse axonal injury (DAI) could be the cause of altered consciousness in the absence of marked intracranial lesions in cranial computed tomography. However, distinguishing CFE and DAI can be difficult clinically. Generally, DAI develops immediately after the insult, whereas CFE occurs 48 to 72 hours after the trauma and even after internal fixation for the fractures. Fat embolism syndrome develops within an average of 48.5 hours after long bone fracture [1] but has never been reported to occur in less than 2 hours. Here, we present a patient who developed hyperacute CFE and eventually had poor neurological outcome, in contrast to previous reports stating that CFE usually has a long latent period and favorable outcomes.

  4. Short-term effect of zoledronic acid upon fracture resistance of the mandibular condyle and femoral head in an animal model.

    PubMed

    Camacho-Alonso, Fabio; López-Jornet, Pía; Vicente-Hernández, Ascensión

    2013-05-01

    The aim of this study was to compare the effects in terms of resistance to fracture of the mandibular condyle and femoral head following different doses of zoledronic acid in an animal model. A total of 80 adult male Sprague-Dawley rats were included in a prospective randomized study. The animals were randomly divided into four groups of 20 rats each. Group 1 (control) received sterile saline solution, while groups 2, 3 and 4 received a accumulated dose of 0.2 mg, 0.4 mg and 0.6 mg of zoledronic acid, respectively. The animals were sacrificed 28 days after the last dose, and the right hemimandible and the right femur were removed. The fracture strength was measured (in Newtons) with a universal test machine using a 1 kN load connected to a metal rod with one end angled at 30 degrees. The cross-head speed was 1 mm/min. Later, the specimens were observed under a scanning electron microscope with backscattered electron imaging (SEM-BSE). At last, chemical analysis and elemental mapping of the mineral bone composition were generated using a microanalytical system based on energy-dispersive and X-ray spectrometry (EDX). A total of 160 fracture tests were performed. The fracture resistance increased in mandible and femur with a higher accumulated dose of zoledronic acid. Statistically significant differences were recorded versus the controls with all the studies groups. The chemical analysis in mandible showed a significantly increased of calcium and phosphorous to compare the control with all of the study groups; however, in femur no statistically significant differences between the four study groups were observed. The administration of bisphosphonates increases the fracture resistance in mandible and femur.

  5. Dual-energy X-ray absorptiometry derived structural geometry for stress fracture prediction in male U.S. Marine Corps recruits.

    PubMed

    Beck, T J; Ruff, C B; Mourtada, F A; Shaffer, R A; Maxwell-Williams, K; Kao, G L; Sartoris, D J; Brodine, S

    1996-05-01

    A total of 626 U.S. male Marine Corps recruits underwent anthropometric measurements and dual-energy X-ray absorptiometry (DXA) scans of the femoral midshaft and the distal third of the tibia prior to a 12 week physical training program. Conventionally obtained frontal plane DXA scan data were used to measure the bone mineral density (BMD) as well as to derive the cross-sectional area, moment of inertia, section modulus, and bone width in the femur, tibia, and fibula. During training, 23 recruits (3.7%) presented with a total of 27 radiologically confirmed stress fractures in various locations in the lower extremity. After excluding 16 cases of shin splints, periostitis, and other stress reactions that did not meet fracture definition criteria, we compared anthropometric and bone structural geometry measurements between fracture cases and the remaining 587 normals. There was no significant difference in age (p = 0.8), femur length (p = 0.2), pelvic width (p = 0.08), and knee width at the femoral condyles (p = 0.06), but fracture cases were shorter (p = 0.01), lighter (p = 0.0006), and smaller in most anthropometric girth dimensions (p < 0.04). Fracture case bone cross-sectional areas (p < 0.001), moments of inertia (p < 0.001), section moduli (p < 0.001), and widths (p < 0.001) as well as BMD (p < 0.03) were significantly smaller in the tibia and femur. After correcting for body weight differences, the tibia cross-sectional area (p = 0.03), section modulus (p = 0.05), and width (p = 0.03) remained significantly smaller in fracture subjects. We conclude that both small body weight and small diaphyseal dimensions relative to body weight are factors predisposing to the development of stress fractures in this population. These results suggest that bone structural geometry measurements derived from DXA data may provide a simple noninvasive methodology for assessing the risk of stress fracture.

  6. Fabricated torque shaft

    DOEpatents

    Mashey, Thomas Charles

    2002-01-01

    A fabricated torque shaft is provided that features a bolt-together design to allow vane schedule revisions with minimal hardware cost. The bolt-together design further facilitates on-site vane schedule revisions with parts that are comparatively small. The fabricated torque shaft also accommodates stage schedules that are different one from another in non-linear inter-relationships as well as non-linear schedules for a particular stage of vanes.

  7. The cumulative effect of bisphosphonates and statins on stress fractures. Is it a failure of steroid biosynthesis? Case Report.

    PubMed

    Dzugan, Sergey S; Dzugan, Sergey A

    2016-01-01

    Osteoporosis related fractures pose a significant economic and healthcare problem. There is a growing concern about increased numbers of stress or low energy fractures after bisphosphonates therapy. A 65-year-old woman is presented with a stress fracture of the left femur. From our point of view, this fracture was associated with a long-term statin and bisphosphonate therapy. We did not find a similar presentation in medical literature.

  8. 30 CFR 57.19100 - Shaft landing gates.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Shaft landing gates. 57.19100 Section 57.19100 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... Shafts § 57.19100 Shaft landing gates. Shaft landings shall be equipped with substantial safety gates so...

  9. 30 CFR 57.19100 - Shaft landing gates.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Shaft landing gates. 57.19100 Section 57.19100 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... Shafts § 57.19100 Shaft landing gates. Shaft landings shall be equipped with substantial safety gates so...

  10. Automated Acquisition of Proximal Femur Morphological Characteristics

    NASA Astrophysics Data System (ADS)

    Tabakovic, Slobodan; Zeljkovic, Milan; Milojevic, Zoran

    2014-10-01

    The success of the hip arthroplasty surgery largely depends on the endoprosthesis adjustment to the patient's femur. This implies that the position of the femoral bone in relation to the pelvis is preserved and that the endoprosthesis position ensures its longevity. Dimensions and body shape of the hip joint endoprosthesis and its position after the surgery depend on a number of geometrical parameters of the patient's femur. One of the most suitable methods for determination of these parameters involves 3D reconstruction of femur, based on diagnostic images, and subsequent determination of the required geometric parameters. In this paper, software for automated determination of geometric parameters of the femur is presented. Detailed software development procedure for the purpose of faster and more efficient design of the hip endoprosthesis that ensures patients' specific requirements is also offered

  11. Shaft-Angle Sensor Based on Tunnel-Diode Oscillator

    NASA Technical Reports Server (NTRS)

    Chui, Talso

    2008-01-01

    A proposed brushless shaft-angle sensor for use in extreme cold would offer significant advantages over prior such sensors: (1) It would be capable of operating in extreme cold; and (2) Its electronic circuitry would be simpler than that of a permanent-magnet/ multiple-Hall-probe shaft-angle sensor that would otherwise ordinarily be used to obtain comparable angular resolution. The principle of operation of the proposed shaft-angle sensor requires that the shaft (or at least the portion of the shaft at the sensor location) be electrically insulating. The affected portion of the shaft would be coated with metal around half of its circumference. Two half-circular-cylinder electrodes having a radius slightly larger than that of the shaft would be mounted on the stator, concentric with the shaft, so that there would be a small radial gap between them and the outer surface of the shaft. Hence, there would be a capacitance between each stationary electrode and the metal coat on the shaft.

  12. [Clinical observation of proximal femoral anti-rotation nail for the treatment of femoral intertrochanteric fracture].

    PubMed

    Sun, Fang-Gui; Wang, De-Xin; Hu, Yu-Tong; Xu, Rong-Ming

    2017-10-25

    To explore the curative effect and the recessive loss of blooding of PFNA for the treatment of intertrochanteric fractures of femur. From January 2012 to January 2015, a total of 49 patients with intertrochanteric fractures of femur were treated with proximal femoral anti-rotation nail including 41 males and 8 females with an average age of 79 years old ranging from 65 to 91 years old. According to the modified Evans type, 1 case was type I, 12 cases were type II, 36 cases were type III. All cases were fresh fractures. Patients had hip pain, movement limited, joint swelling, bruising, extorsion deformity, X-ray and CT examination showed completely fractures. All patients were treated by closed reduction and PFNA internal fixation. Three comminuted fractures using closed reduction were not satisfied, then were treated by limited PFNA fixation after open reduction. The patients' incision got the grade A healing, no complications such as infection and internal fixation failure happened. All patients were followed up from 6 to 36 months (means 22 months). The pain VAS score decreased from preoperative 7.70±1.97 to 1.00±0.26 at 6 months after operation( P <0.01). Harris hip score improved from preoperative 8.70±4.19 to 91.70±5.31 at 6 months after operation( P <0.01). The outcome at 6 months after operation was excellent in 34 cases, good in 7, poor in 1. The fracture healing time was from 8 to 16 weeks with an average of 12 weeks after operation. One patient with osteoporosis, crushing broken, poor compliance, associated with schizophrenia at the same time, appeared with the displacement of the femoral greater trochanter, with conservative treatment for healing. Intertrochanteric fractures of femur are common in the elderly trauma, in pain relief, recovery of hip function, to provide quality of life for the patients, PFNA achieved satisfactory effect, but its existence is worth to pay close attention to the recessive loss of blood.

  13. Femoral diaphyseal stress fracture as the initial presentation of acute leukaemia in an adolescent.

    PubMed

    Chase, Helen Emily; Pang, Joe Hwong; Sanghrajka, Anish Pradip

    2016-06-28

    A 14-year-old boy was referred to the orthopaedic clinic by his general practitioner, reporting of a 6-week history of left thigh pain. Clinical examination was unremarkable. Radiographs demonstrated a periosteal reaction at the proximal femur. MRI scans demonstrated a stress fracture of the femur, with no associated sinister features and no evidence of a pathological lesion. As the fracture healed and symptoms improved, the patient became unwell with weight loss, lethargy, chest and jaw pain and fevers. After multiple blood tests over a 25-day period, including five full blood counts and two normal blood films, a third blood film finally demonstrated blasts in keeping with acute leukaemia. We discuss a literature review of musculoskeletal manifestations of leukaemia and the often atypical presentations found. 2016 BMJ Publishing Group Ltd.

  14. Fracture following lower limb lengthening in children: a series of 58 patients.

    PubMed

    Launay, F; Younsi, R; Pithioux, M; Chabrand, P; Bollini, G; Jouve, J-L

    2013-02-01

    Fracture is one of the main complications following external fixator removal used in cases of progressive lower limb lengthening; rates as high as 50% are found in the literature. The aim of this study was to determine the factors influencing this complication. One hundred and eleven cases of lower limb lengthening were performed in 58 patients (40 femurs and 71 tibias). The mean age at surgery was 10.1years old. Lengthening was performed in all cases with an external fixator alone, associated in 39.6% of cases with intramedullary nailing. The patients were divided into three groups according to disease etiology (congenital, achondroplasia and other). The fractures were classified according to the Simpson classification. Twenty fractures were recorded (18%). Sixteen fractures were found in patients with congenital disease, four with achondroplasia and none in the group of other etiologies. The fracture was more often in the femur (27.5%) than in the tibia (12.7%). The rate of fracture is influenced by different factors depending on the etiology of disease. In congenital diseases, the fracture rate is higher when there is lengthening of more than 15% of the initial length and a delay between surgery and the beginning of lengthening of less than 7days. In patients with achondroplasia, the influence of a relative percentage of lengthening is less important than in those with congenital disease. However, to avoid fractures, lengthening should not be started in children under the age of nine. Moreover, lengthening should begin at least 7days after the fixator has been placed. Retrospective. Level IV. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  15. Fracture bone healing and biodegradation of AZ31 implant in rats.

    PubMed

    Iglesias, C; Bodelón, O G; Montoya, R; Clemente, C; Garcia-Alonso, M C; Rubio, J C; Escudero, M L

    2015-04-17

    The ideal temporary implant should offer enough mechanical support to allow healing of the fracture and then biodegrade and be resorbed by metabolic mechanisms without causing any toxic effect. The aim of this research has been to simultaneously study in situ bone healing and the biodegradation of AZ31 Mg alloy as an osteosynthesis material. The in vivo study was carried out in AZ31 implants with and without Mg-fluoride coating inserted in un-fractured and fractured femurs of Wistar rats for long experimentation time, from 1 to 13 months, by means of computed tomography, histological and histomorphometric analysis. Tomography analysis showed the bone healing and biodegradation of AZ31 implants. The fracture is healed in 100% of the animals, and AZ31 maintains its mechanical integrity throughout the healing process. Biodegradation was monitored, quantifying the evolution of gas over time by 3D composition of tomography images. In all the studied groups, gas pockets disappear with time as a result of the diffusion process through soft tissues. Histomorphometric studies reveal that after 13 months the 46.32% of AZ31 alloy has been resorbed. The resorption of the coated and uncoated AZ31 implants inserted in fractured femurs after 1, 9 and 13 months does not have statistically significant differences. There is a balance between the biodegradation of AZ31 and bone healing which allows the use of AZ31 to be proposed as an osteosynthesis material.

  16. Total Hip Intraoperative Femur Fracture: Do the Design Enhancements of a Second-Generation Tapered-Wedge Stem Reduce the Incidence?

    PubMed

    Colacchio, Nicholas D; Robbins, Claire E; Aghazadeh, Mehran S; Talmo, Carl T; Bono, James V

    2017-10-01

    Intraoperative femur fracture (IFF) is a well-known complication in primary uncemented total hip arthroplasty (THA). Variations in implant instrumentation design and operative technique may influence the risk of IFF. This study investigates IFF between a standard uncemented tapered-wedge femoral stem and its second-generation successor with the following design changes: size-specific medial curvature, proportional incremental stem growth, modest reduction in stem length, and distal lateral relief. A single experienced surgeon's patient database was retrospectively queried for IFF occurring during primary uncemented THA using a standard tapered-wedge femoral stem system or a second-generation stem. All procedures were performed using soft tissue preserving anatomic capsule repair and posterior approach. The primary outcome measure was IFF. A z-test of proportions was performed to determine significant difference between the 2 stems with respect to IFF. Patient demographics, Dorr classification, and implant characteristics were also examined. Forty-one of 1510 patients (2.72%) who received a standard tapered-wedge femoral stem sustained an IFF, whereas 5 of 800 patients (0.63%) using the second-generation stem incurred an IFF. No other significant associations were found. A standard tapered-wedge femoral stem instrumentation system resulted in greater than 4 times higher incidence of IFF than its second-generation successor used for primary uncemented THA. Identifying risk factors for IFF is necessary to facilitate implant system improvements and thus maximize patient outcomes. Copyright © 2017. Published by Elsevier Inc.

  17. Parametric instability of shaft with discs

    NASA Astrophysics Data System (ADS)

    Wahab, A. M. Abdul; Rasid, Z. A.; Abu, A.; Rudin, N. F. Mohd Noor

    2017-12-01

    The occurrence of resonance is a major criterion to be considered in the design of shaft. While force resonance occurs merely when the natural frequency of the rotor system equals speed of the shaft, parametric resonance or parametric instability can occur at excitation speed that is integral or sub-multiple of the frequency of the rotor. This makes the study on parametric resonance crucial. Parametric instability of a shaft system consisting of a shaft and disks has been investigated in this study. The finite element formulation of the Mathieu-Hill equation that represents the parametric instability problem of the shaft is developed based on Timoshenko’s beam theory and Nelson’s finite element method (FEM) model that considers the effect of torsional motion on such problem. The Bolotin’s method is used to determine the regions of instability and the Strut-Ince diagram. The validation works show that the results of this study are in close agreement to past results. It is found that a larger radius of disk will cause the shaft to become more unstable compared to smaller radius although both weights are similar. Furthermore, the effect of torsional motion on the parametric instability of the shaft is significant at higher rotating speed.

  18. The effects of once-weekly teriparatide on hip structure and biomechanical properties assessed by CT.

    PubMed

    Ito, M; Oishi, R; Fukunaga, M; Sone, T; Sugimoto, T; Shiraki, M; Nishizawa, Y; Nakamura, T

    2014-03-01

    Once-weekly administration of 56.5 μg teriparatide improved cortical bone parameters and biomechanical parameters at the proximal femur by CT geometry analysis. The aim of this study was to evaluate the effects of weekly administration of teriparatide [human PTH (1-34)] on bone geometry, volumetric bone mineral density (vBMD), and parameters of bone strength at the proximal femur which were longitudinally investigated using computed tomography (CT). The subjects were a subgroup of a recent, randomly assigned, double-blind study (578 subjects) comparing the anti-fracture efficacy of a once-weekly subcutaneous injection of 56.5 μg teriparatide with placebo (TOWER trial). Sixty-six ambulatory postmenopausal women with osteoporosis were enrolled at 15 study sites having multi-detector row CT, and included women injected with teriparatide (n = 29, 74.2 ± 5.1 years) or with placebo (n = 37, 74.8 ± 5.3 years). CT data were obtained at baseline and follow-up scans were performed at 48 and 72 weeks. The data were analyzed to obtain cross-sectional densitometric, geometric, and biomechanical parameters including the section modulus (SM) and buckling ratio (BR) of the femoral neck, inter-trochanter, and femoral shaft. We found that once-weekly teriparatide increased cortical thickness/cross-sectional area (CSA) and total area, and improved biomechanical properties (i.e., decreasing BR) at the femoral neck and shaft. Teriparatide did not change the cortical perimeter. Our longitudinal analysis of proximal femur geometry by CT revealed that once-weekly administration of 56.5 μg teriparatide improved cortical bone parameters at the femoral neck and shaft and also improved biomechanical parameters.

  19. The Incidence of Atypical Femoral Fractures in Patients with Rheumatic Disease: Yamagata Prefectural Committee of Atypical Femoral Fractures (YamaCAFe) Study.

    PubMed

    Takakubo, Yuya; Ohta, Daichi; Ishi, Masaji; Ito, Juji; Oki, Hiroharu; Naganuma, Yasushi; Uno, Tomohiro; Sasaki, Akiko; Akabane, Takeru; Dairaku, Katsuyuki; Goto, Shinichi; Goto, Yasuo; Kanauchi, Yumiko; Kobayashi, Shinji; Nakajima, Taku; Masuda, Keiji; Matsuda, Michiharu; Mura, Nariyuki; Takenouchi, Kenji; Tsuchida, Hiroyuki; Onuma, Yasushi; Shibuya, Junichirou; Seino, Mitsuyoshi; Yamaguchi, Osamu; Hiragami, Ken; Urayama, Yasuhiro; Furukawa, Takashi; Okuda, Shouta; Ogura, Ken; Nakamura, Takeshi; Sasaki, Kan; Konta, Tsuneo; Takagi, Michiaki

    2017-08-01

    Atypical femoral fractures (AFFs) have been reported to occur with minimal or spontaneous subtrochanteric and femoral shaft fractures with a characteristic transverse pattern, compared with typical femoral fractures in young patients with high-energy trauma. AFFs are related to long-term use of bisphosphonates (BPs), glucocorticoids and rheumatic diseases. We have estimated a blind analysis of AFFs in rheumatic patients receiving BPs and glucocorticoids ordinary over a long time in all Yamagata prefectural area through radiographic examination. The 123 AFFs including suspected cases over six years were collected and reviewed by two independent orthopedic surgeons. We found 86 patients with a total of 99 AFFs between 2009 and 2014 (1.43 cases/100,000 person/year). Of these 99 AFFs, 11 were in 8 rheumatic patients including three patients with bilateral AFFs. The incidence of AFFs in rheumatic patients had trend to increase from 2012. The mean age of all 8 patients was 54.9 years. All 8 patients received BPs and 7/8 received prednisolone (PSL). The mean dose of PSL was 14 mg/day. Compared to patients with unilateral AFFs, those with bilateral AFFs in rheumatic patients were on a higher dose of PSL (20 mg/day vs. 7 mg/day) and had less femoral neck-shaft angle (129° vs. 136°, p < 0.05). In conclusion, the incidence of AFFs in rheumatic patients showed a trend to increase from 2012 to 2014 in Yamagata prefecture. Careful management of AFFs is of particular importance in rheumatic patients who have taken high doses of PSL and have small femoral neck-shaft angle.

  20. An animal model of co-existing sarcopenia and osteoporotic fracture in senescence accelerated mouse prone 8 (SAMP8).

    PubMed

    Zhang, Ning; Chow, Simon Kwoon Ho; Leung, Kwok Sui; Lee, Ho Hin; Cheung, Wing Hoi

    2017-10-15

    Sarcopenia and osteoporotic fracture are common aging-related musculoskeletal problems. Recent evidences report that osteoporotic fracture patients showed high prevalence of sarcopenia; however, current clinical practice basically does not consider sarcopenia in the treatment or rehabilitation of osteoporotic fracture. There is almost no report studying the relationship of the co-existing of sarcopenia and osteoporotic fracture healing. In this study, we validated aged senescence accelerated mouse prone 8 (SAMP8) and senescence accelerated mouse resistant 1 (SAMR1) as animal models of senile osteoporosis with/without sarcopenia. Bone mineral density (BMD) at the 5th lumbar and muscle testing of the two animal strains were measured to confirm the status of osteoporosis and sarcopenia, respectively. Closed fracture was created on the right femur of 8-month-old animals. Radiographs were taken weekly post-fracture. MicroCT and histology of the fractured femur were performed at week 2, 4 and 6 post-fracture, while mechanical test of both femora at week 4 and 6 post-fracture. Results showed that the callus of SAMR1 was significantly larger at week 2 but smaller at week 6 post-fracture than SAMP8. Mechanical properties were significantly better at week 4 post-fracture in SAMR1 than SAMP8, indicating osteoporotic fracture healing was delayed in sarcopenic SAMP8. This study validated an animal model of co-existing sarcopenia and osteoporotic fracture, where a delayed fracture healing might be resulted in the presence of sarcopenia. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Polygonal shaft hole rotor

    DOEpatents

    Hussey, John H.; Rose, John Scott; Meystrik, Jeffrey J.; White, Kent Lee

    2001-01-23

    A laminated rotor for an induction motor has a plurality of ferro-magnetic laminations mounted axially on a rotor shaft. Each of the plurality of laminations has a central aperture in the shape of a polygon with sides of equal length. The laminations are alternatingly rotated 180.degree. from one another so that the straight sides of the polygon shaped apertures are misaligned. As a circular rotor shaft is press fit into a stack of laminations, the point of maximum interference occurs at the midpoints of the sides of the polygon (i.e., at the smallest radius of the central apertures of the laminations). Because the laminates are alternatingly rotated, the laminate material at the points of maximum interference yields relatively easily into the vertices (i.e., the greatest radius of the central aperture) of the polygonal central aperture of the next lamination as the shaft is inserted into the stack of laminations. Because of this yielding process, the amount of force required to insert the shaft is reduced, and a tighter fit is achieved.

  2. Shaft seal system

    DOEpatents

    Kapich, Davorin D.

    1985-01-01

    A shaft seal system is disclosed for isolating two regions of different fluid mediums through which a rotatable shaft extends. The seal system includes a seal housing through which the shaft extends and which defines an annular land and an annular labyrinth both of which face on the shaft so that each establishes a corresponding fluid sealing annulus. A collection cavity is formed in communication with the annular sealing spaces, and fluids compatible with the fluids in each of the two regions to be isolated are introduced, respectively, into the annular sealing spaces and collected in the collection cavity from which the fluid mixture is removed and passed to a separator which separates the fluids and returns them to their respective annular sealing spaces in a recycling manner. In the illustrated embodiment, the isolated fluid mediums comprise a liquid region and a gas region. Gas is removed from the gas region and passed through a purifier and a gas pump operative to introduce the purified gas through the labyrinth sealing annulus to the collection cavity. After passing to the separator, the separated gas is passed through a dryer from which the dried gas is caused to pass through the labyrinth sealing annulus into the collection cavity independently of the purified gas so as to insure isolation of the gas region in the event of sealing gas pump malfunction.

  3. Cerebral fat embolism: pulmonary contusion is a more important etiology than long bone fractures.

    PubMed

    Aydin, M D; Akçay, F; Aydin, N; Gündogdu, C

    2005-01-01

    Lipid embolism is a serious and life-threatening problem and usually arises as a complication of severe trauma associated with long bone or pelvic fractures. It is generally thought that fat droplets enter the circulation at the site of fracture. In the systemic circulation, they become emboli to brain, kidney and other areas. Lipids are absorbed from the intestinal tract and transported into pulmonary tissue via thoracic duct and exposed to first catabolic procedures in the lungs. We have predicted that systemic lipid embolism may not occur unless bone fractures lead to pulmonary injury. This study was planned to investigate this hypothesis with respect to the role of pulmonary contusion and long bone fractures in the formation of cerebral fat embolism. Twenty male hybrid rabbits were included in this study. Pulmonary contusion was performed on half of the rabbits (n = 10) and femur fracture was applied to the remaining ones (n = 10). Ten days after procedure, all rabbits were sacrificed. Brain specimens were taken by frozen-section method and stained with Sudan black. Intraarteriolar lipid particles in the brain were examined microscopically. Cerebral fat embolism was detected in seven animals exposed to pulmonary contusion and only in one animal exposed to femur fracture. The mean number of branches of middle cerebral artery at midparietal level occluded with fat particles were higher in the pulmonary contusion group than in the long bone fracture group. In conclusion, we found that pulmonary contusion had more deleterious effects than long bone fracture in the formation of cerebral fat embolism.

  4. Tachometer Derived From Brushless Shaft-Angle Resolver

    NASA Technical Reports Server (NTRS)

    Howard, David E.; Smith, Dennis A.

    1995-01-01

    Tachometer circuit operates in conjunction with brushless shaft-angle resolver. By performing sequence of straightforward mathematical operations on resolver signals and utilizing simple trigonometric identity, generates voltage proportional to rate of rotation of shaft. One advantage is use of brushless shaft-angle resolver as main source of rate signal: no brushes to wear out, no brush noise, and brushless resolvers have proven robustness. No switching of signals to generate noise. Another advantage, shaft-angle resolver used as shaft-angle sensor, tachometer input obtained without adding another sensor. Present circuit reduces overall size, weight, and cost of tachometer.

  5. The Loss of Activating Transcription Factor 4 (ATF4) Reduces Bone Toughness and Fracture Toughness

    PubMed Central

    Makowski, Alexander J.; Uppuganti, Sasidhar; Waader, Sandra A.; Whitehead, Jack M.; Rowland, Barbara J.; Granke, Mathilde; Mahadevan-Jansen, Anita; Yang, Xiangli; Nyman, Jeffry S.

    2014-01-01

    Even though age-related changes to bone tissue affecting fracture risk are well characterized, only a few matrix-related factors have been identified as important to maintaining fracture resistance. As a gene critical to osteoblast differentiation, activating transcription factor 4 (ATF4) is possibly one of the seimportant factors. To test the hypothesis that the loss of ATF4 affects the fracture resistance of bone beyond bone mass and structure, we harvested bones from Atf4+/+ and Atf4−/− littermates at 8 and 20 weeks of age (n≥9 per group) for bone assessment across several length scales. From whole bone mechanical tests in bending, femurs from Atf4−/− mice were found to be brittle with reduced toughness and fracture toughness compared to femurs from Atf4+/+ mice. However, there were no differences in material strength and in tissue hardness, as determined by nanoindentation, between the genotypes, irrespective age. Tissue mineral density of the cortex at the point of loading as determined by micro-computed tomography was also not significantly different. However, by analyzing local composition by Raman Spectroscopy (RS), bone tissue of Atf4−/− mice was found to have higher mineral to collagen ratio compared to wild-type tissue, primarily at 20 weeks of age. From RS analysis of intact femurs at 2 orthogonal orientations relative to the polarization axis of the laser, we also found that the organizational-sensitive peak ratio, ν1 Phosphate per Amide I, changed to a greater extent upon bone rotation for Atf4-deficient tissue, implying bone matrix organization may contribute to the brittleness phenotype. Target genes of ATF4 activity are not only important to osteoblast differentiation but also maintaining bone toughness and fracture toughness. PMID:24509412

  6. The loss of activating transcription factor 4 (ATF4) reduces bone toughness and fracture toughness.

    PubMed

    Makowski, Alexander J; Uppuganti, Sasidhar; Wadeer, Sandra A; Whitehead, Jack M; Rowland, Barbara J; Granke, Mathilde; Mahadevan-Jansen, Anita; Yang, Xiangli; Nyman, Jeffry S

    2014-05-01

    Even though age-related changes to bone tissue affecting fracture risk are well characterized, only a few matrix-related factors have been identified as important to maintaining fracture resistance. As a gene critical to osteoblast differentiation, activating transcription factor 4 (ATF4) is possibly one of these important factors. To test the hypothesis that the loss of ATF4 affects the fracture resistance of bone beyond bone mass and structure, we harvested bones from Atf4+/+ and Atf4-/- littermates at 8 and 20 weeks of age (n≥9 per group) for bone assessment across several length scales. From whole bone mechanical tests in bending, femurs from Atf4-/- mice were found to be brittle with reduced toughness and fracture toughness compared to femurs from Atf4+/+ mice. However, there were no differences in material strength and in tissue hardness, as determined by nanoindentation, between the genotypes, irrespective of age. Tissue mineral density of the cortex at the point of loading as determined by micro-computed tomography was also not significantly different. However, by analyzing local composition by Raman Spectroscopy (RS), bone tissue of Atf4-/- mice was found to have higher mineral to collagen ratio compared to wild-type tissue, primarily at 20 weeks of age. From RS analysis of intact femurs at 2 orthogonal orientations relative to the polarization axis of the laser, we also found that the organizational-sensitive peak ratio, ν1Phosphate per Amide I, changed to a greater extent upon bone rotation for Atf4-deficient tissue, implying bone matrix organization may contribute to the brittleness phenotype. Target genes of ATF4 activity are not only important to osteoblast differentiation but also in maintaining bone toughness and fracture toughness. Published by Elsevier Inc.

  7. Fat embolism due to bilateral femoral fracture: a case report.

    PubMed

    Porpodis, Konstantinos; Karanikas, Michael; Zarogoulidis, Paul; Konoglou, Maria; Domvri, Kalliopi; Mitrakas, Alexandros; Boglou, Panagiotis; Bakali, Stamatia; Iordanidis, Alkis; Zervas, Vasilis; Courcoutsakis, Nikolaos; Katsikogiannis, Nikolaos; Zarogoulidis, Konstantinos

    2012-01-01

    Fat embolism syndrome is usually associated with surgery for large bone fractures. Symptoms usually occur within 36 hours of hospitalization after traumatic injury. We present a case with fat embolism syndrome due to femur fracture. Prompt supportive treatment of the patient's respiratory system and additional pharmaceutical treatment provided the positive clinical outcome. There is no specific therapy for fat embolism syndrome; prevention, early diagnosis, and adequate symptomatic treatment are very important. Most of the studies in the last 20 years have shown that the incidence of fat embolism syndrome is reduced by early stabilization of the fractures and the risk is even further decreased with surgical correction rather than conservative management.

  8. [Treatment of trochanteric fractures of the femoral bone].

    PubMed

    Wierer, I; Pospísil, M; Holubár, J; Volf, V

    1994-01-01

    The authors present the evaluation of some most often methods of treatment of trochanteric fractures of femur. They analyze the group of 235 patients in the years 1987 - 1991 treated for fractures by the McLaughlin technique and by Ender nailing. The first method was performed on 121 people and the technique of Ender nailing on 97 people. The results and complications of these methods of osteosynthesis are presented in the paper. The experiences of the authors confirm the advantage of Ender nailing in treating fractures of the oldest injured patients. The Ender nailing method of osteosynthesis is the more advantageous, because the operation takes less time and is easier for patients. After Ender nailing, the possibility of functional rehabilitation and walking on crutches is greater. McLaughlin osteosynthesis of these fractures proved the more advantageous in younger injured patients.

  9. Integrated controls and health monitoring fiberoptic shaft monitor

    NASA Technical Reports Server (NTRS)

    Coleman, P.; Darejeh, H.; Collins, J. J.

    1989-01-01

    Recent work was performed on development optical technology to provide real time monitoring of shaft speed, shaft axial displacement, and shaft orbit of the OTVE hydrostatic bearing tester. Results show shaft axial displacement can be optically measured (at the same time as shaft orbital motion and speed) to within 0.3 mills by two fiber optic deflectometers. The final results of this condition monitoring development effort are presented.

  10. Root bark of Sambucus Williamsii Hance promotes rat femoral fracture healing by the BMP-2/Runx2 signaling pathway.

    PubMed

    Yang, Bingyou; Lin, Xiaoying; Tan, Jinyan; She, Xian; Liu, Yan; Kuang, Haixue

    2016-09-15

    Sambucus Williamsii Hance (SWH) is a plant from a family of Caprifoliaceae, which has a long medical history of use as an effective folk treatment for fracture bruises. To evaluate the effects of 50% ethanol extracts of root-bark of Sambucus Williamsii Hance(EE-rbSWH) on fracture healing of rats and explore its mechanism of actions related to the BMP-2 signaling pathway. EE-rbSWH was orally administered at the doses of 340 and 680mg/kg to adult Sprague-Dawley rats with operation of open femur fracture completely for 2, 4 and 8 weeks. And the rats of sham operation and Model groups were administered Vehicle (distilled water 0.8mL/200g/day). Firstly, the bone X-ray morphology and bone mineral density(BMD) of the fracture site were observed and measured after anesthesia the rats at weeks 2, 4, and 8 after surgery, then the serum levels of alkaline phosphatase(ALP) and osteocalcin (BGP) were measured; Secondly, the tissue morphology of the fracture site was observed after sacrificed the rats; Thirdly, the formation of mineralized nodules in bone marrow stromal cells(BMSC) were evaluated at week 2; Lastly, the genes levels of BMP-2 and Runx2 in the femur were detected at week 2 and 4, and the proteins expression of BMP-2 signaling pathway (BMP-2, BMPRIB, BMPRII and Runx2) in the femur also were detected at week 2. EE-rbSWH remarkably accelerated fracture healing by promoting bone formation at all the time points of fracture healing. Mainly by increasing the BMD level at the fracture site, the levels of serum ALP and BGP, and also the numbers increasing of calcified nodules in BMSC. The mechanism studies, EE-rbSWH can promote fracture healing by enhancing the expressions of BMP-2 and Runx2 mRNA, and also the proteins of BMP-2, BMPRIB, BMPRII and Runx2 at the fracture site of rats. Our results suggested that 50% ethanol extracts of root-bark of Sambucus Williamsii Hance can accelerate fracture healing by recruitment of osteoblasts at the fracture site and through up

  11. Design of experiments confirms optimization of lithium administration parameters for enhanced fracture healing.

    PubMed

    Vachhani, Kathak; Pagotto, Andrea; Wang, Yufa; Whyne, Cari; Nam, Diane

    2018-01-03

    Fracture healing is a lengthy process which fails in 5-10% of cases. Lithium, a low-cost therapeutic used in psychiatric medicine, up-regulates the canonical Wingless pathway crucial for osteoblastic mineralization in fracture healing. A design-of-experiments (DOE) methodology was used to optimize lithium administration parameters (dose, onset time and treatment duration) to enhance healing in a rat femoral fracture model. In the previously completed first stage (screening), onset time was found to significantly impact healing, with later (day 7 vs. day 3 post-fracture) treatment yielding improved maximum yield torque. The greatest strength was found in healing femurs treated at day 7 post fracture, with a low lithium dose (20 mg/kg) for 2 weeks duration. This paper describes the findings of the second (optimization) and third (verification) stages of the DOE investigation. Closed traumatic diaphyseal femur fractures were induced in 3-month old rats. Healing was evaluated on day 28 post fracture by CT-based morphometry and torsional loading. In optimization, later onset times of day 10 and 14 did not perform as well as day 7 onset. As such, efficacy of the best regimen (20 mg/kg dose given at day 7 onset for 2 weeks duration) was reassessed in a distinct cohort of animals to complete the DOE verification. A significant 44% higher maximum yield torque (primary outcome) was seen with optimized lithium treatment vs. controls, which paralleled the 46% improvement seen in the screening stage. Successful completion of this robustly designed preclinical DOE study delineates the optimal lithium regimen for enhancing preclinical long-bone fracture healing. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Trochanteric fracture-implant motion during healing - A radiostereometry (RSA) study.

    PubMed

    Bojan, Alicja J; Jönsson, Anders; Granhed, Hans; Ekholm, Carl; Kärrholm, Johan

    2018-03-01

    Cut-out complication remains a major unsolved problem in the treatment of trochanteric hip fractures. A better understanding of the three-dimensional fracture-implant motions is needed to enable further development of clinical strategies and countermeasures. The aim of this clinical study was to characterise and quantify three-dimensional motions between the implant and the bone and between the lag screw and nail of the Gamma nail. Radiostereometry Analysis (RSA) analysis was applied in 20 patients with trochanteric hip fractures treated with an intramedullary nail. The following three-dimensional motions were measured postoperatively, at 1 week, 3, 6 and 12 months: translations of the tip of the lag screw in the femoral head, motions of the lag screw in the nail, femoral head motions relative to the nail and nail movements in the femoral shaft. Cranial migration of the tip of the lag screw dominated over the other two translation components in the femoral head. In all fractures the lag screw slid laterally in the nail and the femoral head moved both laterally and inferiorly towards the nail. All femoral heads translated posteriorly relative to the nail, and rotations occurred in both directions with median values close to zero. The nail tended to retrovert in the femoral shaft. Adverse fracture-implant motions were detected in stable trochanteric hip fractures treated with intramedullary nails with high resolution. Therefore, RSA method can be used to evaluate new implant designs and clinical strategies, which aim to reduce cut-out complications. Future RSA studies should aim at more unstable fractures as these are more likely to fail with cut-out. Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. Endoscope shaft-rigidity control mechanism: "FORGUIDE".

    PubMed

    Loeve, Arjo J; Plettenburg, Dick H; Breedveld, Paul; Dankelman, Jenny

    2012-02-01

    Recent developments in flexible endoscopy and other fields of medical technology have raised the need for compact slender shafts that can be made rigid and compliant at will. A novel compact mechanism, named FORGUIDE, with this functionality was developed. The FORGUIDE shaft rigidifies due to friction between a ring of cables situated between a spring and an inflated tube. A mathematical model for the FORGUIDE mechanism working principle was made and used to obtain understanding of this mechanism, predict the maximum rigidity of a FORGUIDE shaft design, and tune its design variables. The mathematical model gave suggestions for significant performance improvement by fine-tuning the design. A prototype FORGUIDE shaft was built and put to a series of bench tests. These tests showed that the FORGUIDE mechanism provides a reliable and simple way to control the rigidity of a flexible shaft. © 2011 IEEE

  14. Patella Fractures Prior to Total Knee Arthroplasty: Worse Outcomes but Equivalent Survivorship.

    PubMed

    Houdek, Matthew T; Shannon, Steven F; Watts, Chad D; Wagner, Eric R; Sems, Stephen A; Sierra, Rafael J

    2015-12-01

    Distal femur and/or tibial plateau fractures adversely affect outcomes of TKA; however it is unknown if a previous patella fracture affects outcome. We reviewed 113 patients undergoing TKA with a previous patella fracture from 1990 to 2012. Component survival was compared to 19,641 patients undergoing TKA for osteoarthritis during the same period. The 15-year implant survivals following a previous patella fracture was 86%. There was no difference in implant survival compared to patients undergoing TKA for OA (P=0.31). Knee society scores significantly improved following TKA; however patients with a fracture had complications related to knee flexion. Patients undergoing primary TKA following a patella fracture have similar overall revision free survival compared to those undergoing TKA for OA at 15-years. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Semi-rigid screws provide an auxiliary option to plate working length to control interfragmentary movement in locking plate fixation at the distal femur.

    PubMed

    Heyland, Mark; Duda, Georg N; Haas, Norbert P; Trepczynski, Adam; Döbele, Stefan; Höntzsch, Dankward; Schaser, Klaus-Dieter; Märdian, Sven

    2015-10-01

    Extent and orientation of interfragmentary movement (IFM) are crucially affecting course and quality of fracture healing. The effect of different configurations for implant fixation on successful fracture healing remain unclear. We hypothesize that screw type and configuration of locking plate fixation profoundly influences stiffness and IFM for a given load in a distal femur fracture model. Simple analytical models are presented to elucidate the influence of fixation configuration on construct stiffness. Models were refined with a consistent single-patient-data-set to create finite-element femur models. Locking plate fixation of a distal femoral 10mm-osteotomy (comminution model) was fitted with rigid locking screws (rLS) or semi-rigid locking screws (sLS). Systematic variations of screw placements in the proximal fragment were tested. IFM was quantitatively assessed and compared for different screw placements and screw types. Different screw allocations significantly affect IFM in a locking plate construct. LS placement of the first screw proximal to the fracture (plate working length, PWL) has a significant effect on axial IFM (p < 0.001). Replacing rLS with sLS caused an increase (p < 0.001) of IFM under the plate (cis-cortex) between +8.4% and +28.1% for the tested configurations but remained constant medially (<1.1%, trans-cortex). Resultant shear movements markedly increased at fracture level (p < 0.001) to the extent that plate working length increased. The ratio of shear/axial IFM was found to enhance for longer PWL. sLS versus rLS lead to significantly smaller ratios of shear/axial IFM at the cis-cortex for PWL of ≥ 62 mm (p ≤ 0.003). Mechanical frame conditions can be significantly influenced by type and placement of the screws in locking plate osteosynthesis of the distal femur. By varying plate working length stiffness and IFM are modulated. Moderate axial and concomitantly low shear IFM could not be achieved through changes in screw placement

  16. Gravity in a Mine Shaft.

    ERIC Educational Resources Information Center

    Hall, Peter M.; Hall, David J.

    1995-01-01

    Discusses the effects of gravity, local density compared to the density of the earth, the mine shaft, centrifugal force, and air buoyancy on the weight of an object at the top and at the bottom of a mine shaft. (JRH)

  17. Intramedullary nail fixation of non-traditional fractures: Clavicle, forearm, fibula.

    PubMed

    Dehghan, Niloofar; Schemitsch, Emil H

    2017-06-01

    Locked intramedullary fixation is a well-established technique for managing long-bone fractures. While intramedullary nail fixation of diaphyseal fractures in the femur, tibia, and humerus is well established, the same is not true for other fractures. Surgical fixations of clavicle, forearm and ankle are traditionally treated with plate and screw fixation. In some cases, fixation with an intramedullary device is possible, and may be advantageous. However, there is however a concern regarding a lack of rotational stability and fracture shortening. While new generation of locked intramedullary devices for fractures of clavicle, forearm and fibula are recently available, the outcomes are not as reliable as fixation with plates and screws. Further research in this area is warranted with high quality comparative studies, to investigate the outcomes and indication of these fractures treated with intramedullary nail devices compared to intramedullary nail fixation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. EVALUATION OF PRESENTATION OF SIGNS AND SYMPTOMS OF FEMOROACETABULAR IMPINGEMENT AFTER EPIPHYSIOLYSIS OF THE PROXIMAL FEMUR.

    PubMed

    Krüger, Fábio Peng; de Britto, Paulo Sérgio Gérzon; Neto, Lauro Machado; Schwartsmann, Carlos Roberto

    2011-01-01

    The long-bone fractures occur most frequently in the tibial shaft. Adequate treatment of such fractures avoids consolidation failure, skewed consolidation and reoperation. To classify these fractures, the AO/OTA classification method is still used, but it is worthwhile getting to know the Ellis classification method, which also includes assessment of soft-tissue injuries. There is often an association with compartmental syndrome, and early diagnosis can be achieved through evaluating clinical parameters and constant clinical monitoring. Once the diagnosis has been made, fasciotomy should be performed. It is always difficult to assess consolidation, but the RUST method may help in this. Radiography is assessed in two projections, and points are scored for the presence of the fracture line and a visible bone callus. Today, the dogma of six hours for cleaning the exposed fracture is under discussion. It is considered that an early start to intravenous antibiotic therapy and the lesion severity are very important. The question of early or late closure of the lesion in an exposed fracture has gone through several phases: sometimes early closure has been indicated and sometimes late closure. Currently, whenever possible, early closure of the lesion is recommended, since this diminishes the risk of infection. Milling of the canal when the intramedullary nail is introduced is still a controversial subject. Despite strong personal positions in favor of milling, studies have shown that there may be some advantage in relation to closed fractures, but not in exposed fractures.

  19. Fracture of the penis with urethral rupture.

    PubMed

    Roy, Mk; Matin, Ma; Alam, Mm; Suruzzaman, M; Rahman, Mm

    2008-01-01

    We report a rare case of penile fracture with incomplete urethral rupture in a 25 years old male who sustained the injury during sexual intercourse. He presented with a tense haematoma on the ventral aspect of the penile shaft, associated with urethral bleeding. Per urethral catheterization was possible though it was painful. Exploration and repair of the penile fracture and urethra were performed within 16 hrs. The patient made an uneventful recovery with good erectile and voiding function. This case illustrates the value of early surgical repair of the fracture in order to prevent complications. The true incidence of penile fracture is not known even in the Western countries because it is under reported or hidden for social embracement and even it is reported to physicians it remains undiagnosed or mismanaged. Very rarely it is associated with urethral rupture.

  20. DXA and pQCT predict pertrochanteric and not femoral neck fracture load in a human side-impact fracture model.

    PubMed

    Gebauer, Matthias; Stark, Olaf; Vettorazzi, Eik; Grifka, Joachim; Püschel, Klaus; Amling, Michael; Beckmann, Johannes

    2014-01-01

    The validity of dual energy X-ray absorptiometry (DXA) and peripheral quantitative computed tomography (pQCT) measurements as predictors of pertrochanteric and femoral neck fracture loads was compared in an experimental simulation of a fall on the greater trochanter. 65 proximal femora were harvested from patients at autopsy. All specimens were scanned with use of DXA for areal bone mineral density and pQCT for volumetric densities at selected sites of the proximal femur. A three-point bending test simulating a side-impact was performed to determine fracture load and resulted in 16 femoral neck and 49 pertrochanteric fractures. Regression analysis revealed that DXA BMD trochanter was the best variable at predicting fracture load of pertrochanteric fractures with an adjusted R(2) of 0.824 (p < 0.0001). There was no correlation between densitometric parameters and the fracture load of femoral neck fractures. A significant correlation further was found between body weight, height, femoral head diameter, and neck length on the one side and fracture load on the other side, irrespective of the fracture type. Clinically, the DXA BMD trochanter should be favored and integrated routinely as well as biometric and geometric parameters, particularly in elderly people with known osteoporosis at risk for falls. © 2013 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.