Sample records for focus camera suprime-cam

  1. Hyper Suprime-Cam: Camera dewar design

    NASA Astrophysics Data System (ADS)

    Komiyama, Yutaka; Obuchi, Yoshiyuki; Nakaya, Hidehiko; Kamata, Yukiko; Kawanomoto, Satoshi; Utsumi, Yousuke; Miyazaki, Satoshi; Uraguchi, Fumihiro; Furusawa, Hisanori; Morokuma, Tomoki; Uchida, Tomohisa; Miyatake, Hironao; Mineo, Sogo; Fujimori, Hiroki; Aihara, Hiroaki; Karoji, Hiroshi; Gunn, James E.; Wang, Shiang-Yu

    2018-01-01

    This paper describes the detailed design of the CCD dewar and the camera system which is a part of the wide-field imager Hyper Suprime-Cam (HSC) on the 8.2 m Subaru Telescope. On the 1.°5 diameter focal plane (497 mm in physical size), 116 four-side buttable 2 k × 4 k fully depleted CCDs are tiled with 0.3 mm gaps between adjacent chips, which are cooled down to -100°C by two pulse tube coolers with a capability to exhaust 100 W heat at -100°C. The design of the dewar is basically a natural extension of Suprime-Cam, incorporating some improvements such as (1) a detailed CCD positioning strategy to avoid any collision between CCDs while maximizing the filling factor of the focal plane, (2) a spherical washers mechanism adopted for the interface points to avoid any deformation caused by the tilt of the interface surface to be transferred to the focal plane, (3) the employment of a truncated-cone-shaped window, made of synthetic silica, to save the back focal space, and (4) a passive heat transfer mechanism to exhaust efficiently the heat generated from the CCD readout electronics which are accommodated inside the dewar. Extensive simulations using a finite-element analysis (FEA) method are carried out to verify that the design of the dewar is sufficient to satisfy the assigned errors. We also perform verification tests using the actually assembled CCD dewar to supplement the FEA and demonstrate that the design is adequate to ensure an excellent image quality which is key to the HSC. The details of the camera system, including the control computer system, are described as well as the assembling process of the dewar and the process of installation on the telescope.

  2. DWARF IRREGULAR GALAXY LEO A: SUPRIME-CAM WIDE-FIELD STELLAR PHOTOMETRY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stonkutė, Rima; Narbutis, Donatas; Vansevičius, Vladas

    2014-10-01

    We have surveyed a complete extent of Leo A—an apparently isolated gas-rich low-mass dwarf irregular galaxy in the Local Group. The B, V, and I passband CCD images (typical seeing ∼0.''8) were obtained with the Subaru Telescope equipped with the Suprime-Cam mosaic camera. The wide-field (20' × 24') photometry catalog of 38,856 objects (V ∼ 16-26 mag) is presented. This survey is also intended to serve as ''a finding chart'' for future imaging and spectroscopic observation programs of Leo A.

  3. Hyper Suprime-Cam: System design and verification of image quality

    NASA Astrophysics Data System (ADS)

    Miyazaki, Satoshi; Komiyama, Yutaka; Kawanomoto, Satoshi; Doi, Yoshiyuki; Furusawa, Hisanori; Hamana, Takashi; Hayashi, Yusuke; Ikeda, Hiroyuki; Kamata, Yukiko; Karoji, Hiroshi; Koike, Michitaro; Kurakami, Tomio; Miyama, Shoken; Morokuma, Tomoki; Nakata, Fumiaki; Namikawa, Kazuhito; Nakaya, Hidehiko; Nariai, Kyoji; Obuchi, Yoshiyuki; Oishi, Yukie; Okada, Norio; Okura, Yuki; Tait, Philip; Takata, Tadafumi; Tanaka, Yoko; Tanaka, Masayuki; Terai, Tsuyoshi; Tomono, Daigo; Uraguchi, Fumihiro; Usuda, Tomonori; Utsumi, Yousuke; Yamada, Yoshihiko; Yamanoi, Hitomi; Aihara, Hiroaki; Fujimori, Hiroki; Mineo, Sogo; Miyatake, Hironao; Oguri, Masamune; Uchida, Tomohisa; Tanaka, Manobu M.; Yasuda, Naoki; Takada, Masahiro; Murayama, Hitoshi; Nishizawa, Atsushi J.; Sugiyama, Naoshi; Chiba, Masashi; Futamase, Toshifumi; Wang, Shiang-Yu; Chen, Hsin-Yo; Ho, Paul T. P.; Liaw, Eric J. Y.; Chiu, Chi-Fang; Ho, Cheng-Lin; Lai, Tsang-Chih; Lee, Yao-Cheng; Jeng, Dun-Zen; Iwamura, Satoru; Armstrong, Robert; Bickerton, Steve; Bosch, James; Gunn, James E.; Lupton, Robert H.; Loomis, Craig; Price, Paul; Smith, Steward; Strauss, Michael A.; Turner, Edwin L.; Suzuki, Hisanori; Miyazaki, Yasuhito; Muramatsu, Masaharu; Yamamoto, Koei; Endo, Makoto; Ezaki, Yutaka; Ito, Noboru; Kawaguchi, Noboru; Sofuku, Satoshi; Taniike, Tomoaki; Akutsu, Kotaro; Dojo, Naoto; Kasumi, Kazuyuki; Matsuda, Toru; Imoto, Kohei; Miwa, Yoshinori; Suzuki, Masayuki; Takeshi, Kunio; Yokota, Hideo

    2018-01-01

    The Hyper Suprime-Cam (HSC) is an 870 megapixel prime focus optical imaging camera for the 8.2 m Subaru telescope. The wide-field corrector delivers sharp images of 0{^''.}2 (FWHM) in the HSC-i band over the entire 1.5° diameter field of view. The collimation of the camera with respect to the optical axis of the primary mirror is done with hexapod actuators, the mechanical accuracy of which is a few microns. Analysis of the remaining wavefront error in off-focus stellar images reveals that the collimation of the optical components meets design specifications. While there is a flexure of mechanical components, it also is within the design specification. As a result, the camera achieves its seeing-limited imaging on Maunakea during most of the time; the median seeing over several years of observing is 0.67" (FWHM) in the i band. The sensors use p-channel, fully depleted CCDs of 200 μm thickness (2048 × 4176 15 μm square pixels) and we employ 116 of them to pave the 50 cm diameter focal plane. The minimum interval between exposures is 34 s, including the time to read out arrays, to transfer data to the control computer, and to save them to the hard drive. HSC on Subaru uniquely features a combination of a large aperture, a wide field of view, sharp images and a high sensitivity especially at longer wavelengths, which makes the HSC one of the most powerful observing facilities in the world.

  4. The Hyper Suprime-Cam SSP Survey: Overview and survey design

    NASA Astrophysics Data System (ADS)

    Aihara, Hiroaki; Arimoto, Nobuo; Armstrong, Robert; Arnouts, Stéphane; Bahcall, Neta A.; Bickerton, Steven; Bosch, James; Bundy, Kevin; Capak, Peter L.; Chan, James H. H.; Chiba, Masashi; Coupon, Jean; Egami, Eiichi; Enoki, Motohiro; Finet, Francois; Fujimori, Hiroki; Fujimoto, Seiji; Furusawa, Hisanori; Furusawa, Junko; Goto, Tomotsugu; Goulding, Andy; Greco, Johnny P.; Greene, Jenny E.; Gunn, James E.; Hamana, Takashi; Harikane, Yuichi; Hashimoto, Yasuhiro; Hattori, Takashi; Hayashi, Masao; Hayashi, Yusuke; Hełminiak, Krzysztof G.; Higuchi, Ryo; Hikage, Chiaki; Ho, Paul T. P.; Hsieh, Bau-Ching; Huang, Kuiyun; Huang, Song; Ikeda, Hiroyuki; Imanishi, Masatoshi; Inoue, Akio K.; Iwasawa, Kazushi; Iwata, Ikuru; Jaelani, Anton T.; Jian, Hung-Yu; Kamata, Yukiko; Karoji, Hiroshi; Kashikawa, Nobunari; Katayama, Nobuhiko; Kawanomoto, Satoshi; Kayo, Issha; Koda, Jin; Koike, Michitaro; Kojima, Takashi; Komiyama, Yutaka; Konno, Akira; Koshida, Shintaro; Koyama, Yusei; Kusakabe, Haruka; Leauthaud, Alexie; Lee, Chien-Hsiu; Lin, Lihwai; Lin, Yen-Ting; Lupton, Robert H.; Mandelbaum, Rachel; Matsuoka, Yoshiki; Medezinski, Elinor; Mineo, Sogo; Miyama, Shoken; Miyatake, Hironao; Miyazaki, Satoshi; Momose, Rieko; More, Anupreeta; More, Surhud; Moritani, Yuki; Moriya, Takashi J.; Morokuma, Tomoki; Mukae, Shiro; Murata, Ryoma; Murayama, Hitoshi; Nagao, Tohru; Nakata, Fumiaki; Niida, Mana; Niikura, Hiroko; Nishizawa, Atsushi J.; Obuchi, Yoshiyuki; Oguri, Masamune; Oishi, Yukie; Okabe, Nobuhiro; Okamoto, Sakurako; Okura, Yuki; Ono, Yoshiaki; Onodera, Masato; Onoue, Masafusa; Osato, Ken; Ouchi, Masami; Price, Paul A.; Pyo, Tae-Soo; Sako, Masao; Sawicki, Marcin; Shibuya, Takatoshi; Shimasaku, Kazuhiro; Shimono, Atsushi; Shirasaki, Masato; Silverman, John D.; Simet, Melanie; Speagle, Joshua; Spergel, David N.; Strauss, Michael A.; Sugahara, Yuma; Sugiyama, Naoshi; Suto, Yasushi; Suyu, Sherry H.; Suzuki, Nao; Tait, Philip J.; Takada, Masahiro; Takata, Tadafumi; Tamura, Naoyuki; Tanaka, Manobu M.; Tanaka, Masaomi; Tanaka, Masayuki; Tanaka, Yoko; Terai, Tsuyoshi; Terashima, Yuichi; Toba, Yoshiki; Tominaga, Nozomu; Toshikawa, Jun; Turner, Edwin L.; Uchida, Tomohisa; Uchiyama, Hisakazu; Umetsu, Keiichi; Uraguchi, Fumihiro; Urata, Yuji; Usuda, Tomonori; Utsumi, Yousuke; Wang, Shiang-Yu; Wang, Wei-Hao; Wong, Kenneth C.; Yabe, Kiyoto; Yamada, Yoshihiko; Yamanoi, Hitomi; Yasuda, Naoki; Yeh, Sherry; Yonehara, Atsunori; Yuma, Suraphong

    2018-01-01

    Hyper Suprime-Cam (HSC) is a wide-field imaging camera on the prime focus of the 8.2-m Subaru telescope on the summit of Mauna Kea in Hawaii. A team of scientists from Japan, Taiwan, and Princeton University is using HSC to carry out a 300-night multi-band imaging survey of the high-latitude sky. The survey includes three layers: the Wide layer will cover 1400 deg2 in five broad bands (grizy), with a 5 σ point-source depth of r ≈ 26. The Deep layer covers a total of 26 deg2 in four fields, going roughly a magnitude fainter, while the UltraDeep layer goes almost a magnitude fainter still in two pointings of HSC (a total of 3.5 deg2). Here we describe the instrument, the science goals of the survey, and the survey strategy and data processing. This paper serves as an introduction to a special issue of the Publications of the Astronomical Society of Japan, which includes a large number of technical and scientific papers describing results from the early phases of this survey.

  5. Hyper Suprime-Cam: development of the CCD readout electronics

    NASA Astrophysics Data System (ADS)

    Nakaya, Hidehiko; Uchida, Tomohisa; Miyatake, Hironao; Fujimori, Hiroki; Mineo, Sogo; Aihara, Hiroaki; Furusawa, Hisanori; Kamata, Yukiko; Karoji, Hiroshi; Kawanomoto, Satoshi; Komiyama, Yutaka; Miyazaki, Satoshi; Morokuma, Tomoki; Obuchi, Yoshiyuki; Okura, Yuki; Tanaka, Manobu; Tanaka, Yoko; Uraguchi, Fumihiro; Utsumi, Yosuke

    2010-07-01

    Hyper Suprime-Cam (HSC) employs 116 of 2k×4k CCDs with 464 signal outputs in total. The image size exceeds 2 GBytes, and the data can be readout every 10 seconds which results in the data rate of 210 Mbytes / sec. The data is digitized to 16-bit. The readout noise of the electronics at the readout time of 20 seconds is ~0.9 ADU, and the one with CCD is ~1.5 ADU which corresponds to ~4.5 e. The linearity error fits within +/- 0.5 % up to 150,000 e. The CCD readout electronics for HSC was newly developed based on the electronics for Suprime-Cam. The frontend electronics (FEE) is placed in the vacuum dewar, and the backend electronics (BEE) is mounted on the outside of the dewar on the prime focus unit. The FEE boards were designed to minimize the outgas and to maximize the heat transfer efficiency to keep the vacuum of the dewar. The BEE boards were designed to be simple and small as long as to achieve the readout time within 10 seconds. The production of the system has been finished, and the full set of the boards are being tested with several CCDs installed in the HSC dewar. We will show the system design, performance, and the current status of the development.

  6. Hyper Suprime-Cam: characteristics of 116 fully depleted back-illuminated CCDs

    NASA Astrophysics Data System (ADS)

    Kamata, Yukiko; Miyazaki, Satoshi; Nakaya, Hidehiko; Komiyama, Yutaka; Obuchi, Yoshiyuki; Kawanomoto, Satoshi; Uraguchi, Fumihiro; Utsumi, Yosuke; Suzuki, Hisanori; Miyazaki, Yasuhito; Muramatsu, Masaharu

    2012-07-01

    Hyper Suprime-Cam (HSC)1,2 is a wide field imaging camera with the field of view (FOV) 1.5 degree diameter, which is to be installed at the prime focus of the Subaru Telescope. The large FOV is realized by the 116 2K × 4K pixels fully depleted back-illuminated CCD (FDCCD) with 15 μm pixel square. The acceptance inspection of the CCDs started around the end of 2009 and finished June 2011. We measured basic characteristics such as charge transfer efficiency (CTE), dark current, readout noise, linearity and the number of the dead column for all CCDs, and measured the quantum effciency (QE) of 21 CCDs. As a result, we confirmed exceptional quality and performance fdor all CCDs ans were able to select the best pissible 116 CCDs. We also measured the flatness of each CCD at room temperature, and optimally placed them on the focal plane plate. In this paper, we report the results of the acceptance inspection asn the installation process into the HSC dewar3,4.

  7. Web-based Hyper Suprime-Cam Data Providing System

    NASA Astrophysics Data System (ADS)

    Koike, M.; Furusawa, H.; Takata, T.; Price, P.; Okura, Y.; Yamada, Y.; Yamanoi, H.; Yasuda, N.; Bickerton, S.; Katayama, N.; Mineo, S.; Lupton, R.; Bosch, J.; Loomis, C.

    2014-05-01

    We describe a web-based user interface to retrieve Hyper Suprime-Cam data products, including images and. Users can access data directly from a graphical user interface or by writing a database SQL query. The system provides raw images, reduced images and stacked images (from multiple individual exposures), with previews available. Catalog queries can be executed in preview or queue mode, allowing for both exploratory and comprehensive investigations.

  8. Development of database system for data obtained by Hyper Suprime-Cam on Subaru Telescope

    NASA Astrophysics Data System (ADS)

    Yamada, Yoshihiko; Takata, Tadafumi; Furusawa, Hisanori; Okura, Yuki; Koike, Michitaro; Yamanoi, Hitomi; Mineo, Sogo; Yasuda, Naoki; Bickerton, Steve; Katayama, Nobuhiko; Lupton, Robert H.; Bosch, Jim; Loomis, Craig; Miyatake, Hironao; Price, Paul A.; Smith, Kendrick; Lang, Dustin

    2014-08-01

    Hyper Suprime-Cam (HSC) is the optical and near-infrared wide-field camera equipped on the Subaru Telescope. Its huge field of view (1.5 degree diameter) with 104 CCDs and the large mirror (8.2m) of the telescope will make us to study the Universe more efficiently. The analysis pipeline for HSC data produces processed images, and object catalogs of each CCD and stacked images. For survey in next 5 years, the number of rows in the object catalog table will reach to at least 5 x 109. We show the outline of the database systems of HSC data to store those huge data.

  9. The Hyper Suprime-Cam software pipeline

    NASA Astrophysics Data System (ADS)

    Bosch, James; Armstrong, Robert; Bickerton, Steven; Furusawa, Hisanori; Ikeda, Hiroyuki; Koike, Michitaro; Lupton, Robert; Mineo, Sogo; Price, Paul; Takata, Tadafumi; Tanaka, Masayuki; Yasuda, Naoki; AlSayyad, Yusra; Becker, Andrew C.; Coulton, William; Coupon, Jean; Garmilla, Jose; Huang, Song; Krughoff, K. Simon; Lang, Dustin; Leauthaud, Alexie; Lim, Kian-Tat; Lust, Nate B.; MacArthur, Lauren A.; Mandelbaum, Rachel; Miyatake, Hironao; Miyazaki, Satoshi; Murata, Ryoma; More, Surhud; Okura, Yuki; Owen, Russell; Swinbank, John D.; Strauss, Michael A.; Yamada, Yoshihiko; Yamanoi, Hitomi

    2018-01-01

    In this paper, we describe the optical imaging data processing pipeline developed for the Subaru Telescope's Hyper Suprime-Cam (HSC) instrument. The HSC Pipeline builds on the prototype pipeline being developed by the Large Synoptic Survey Telescope's Data Management system, adding customizations for HSC, large-scale processing capabilities, and novel algorithms that have since been reincorporated into the LSST codebase. While designed primarily to reduce HSC Subaru Strategic Program (SSP) data, it is also the recommended pipeline for reducing general-observer HSC data. The HSC pipeline includes high-level processing steps that generate coadded images and science-ready catalogs as well as low-level detrending and image characterizations.

  10. Exploring the Brighter-fatter Effect with the Hyper Suprime-Cam

    NASA Astrophysics Data System (ADS)

    Coulton, William R.; Armstrong, Robert; Smith, Kendrick M.; Lupton, Robert H.; Spergel, David N.

    2018-06-01

    The brighter-fatter effect has been postulated to arise due to the build up of a transverse electric field, produced as photocharges accumulate in the pixels’ potential wells. We investigate the brighter-fatter effect in the Hyper Suprime-Cam by examining flat fields and moments of stars. We observe deviations from the expected linear relation in the photon transfer curve (PTC), luminosity-dependent correlations between pixels in flat-field images, and a luminosity-dependent point-spread function (PSF) in stellar observations. Under the key assumptions of translation invariance and Maxwell’s equations in the quasi-static limit, we give a first-principles proof that the effect can be parameterized by a translationally invariant scalar kernel. We describe how this kernel can be estimated from flat fields and discuss how this kernel has been used to remove the brighter-fatter distortions in Hyper Suprime-Cam images. We find that our correction restores the expected linear relation in the PTCs and significantly reduces, but does not completely remove, the luminosity dependence of the PSF over a wide range of magnitudes.

  11. The Hyper Suprime-Cam software pipeline

    DOE PAGES

    Bosch, James; Armstrong, Robert; Bickerton, Steven; ...

    2017-10-12

    Here in this article, we describe the optical imaging data processing pipeline developed for the Subaru Telescope’s Hyper Suprime-Cam (HSC) instrument. The HSC Pipeline builds on the prototype pipeline being developed by the Large Synoptic Survey Telescope’s Data Management system, adding customizations for HSC, large-scale processing capabilities, and novel algorithms that have since been reincorporated into the LSST codebase. While designed primarily to reduce HSC Subaru Strategic Program (SSP) data, it is also the recommended pipeline for reducing general-observer HSC data. The HSC pipeline includes high-level processing steps that generate coadded images and science-ready catalogs as well as low-level detrendingmore » and image characterizations.« less

  12. The Hyper Suprime-Cam software pipeline

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bosch, James; Armstrong, Robert; Bickerton, Steven

    Here in this article, we describe the optical imaging data processing pipeline developed for the Subaru Telescope’s Hyper Suprime-Cam (HSC) instrument. The HSC Pipeline builds on the prototype pipeline being developed by the Large Synoptic Survey Telescope’s Data Management system, adding customizations for HSC, large-scale processing capabilities, and novel algorithms that have since been reincorporated into the LSST codebase. While designed primarily to reduce HSC Subaru Strategic Program (SSP) data, it is also the recommended pipeline for reducing general-observer HSC data. The HSC pipeline includes high-level processing steps that generate coadded images and science-ready catalogs as well as low-level detrendingmore » and image characterizations.« less

  13. Improving Photometric Redshifts for Hyper Suprime-Cam

    NASA Astrophysics Data System (ADS)

    Speagle, Josh S.; Leauthaud, Alexie; Eisenstein, Daniel; Bundy, Kevin; Capak, Peter L.; Leistedt, Boris; Masters, Daniel C.; Mortlock, Daniel; Peiris, Hiranya; HSC Photo-z Team; HSC Weak Lensing Team

    2017-01-01

    Deriving accurate photometric redshift (photo-z) probability distribution functions (PDFs) are crucial science components for current and upcoming large-scale surveys. We outline how rigorous Bayesian inference and machine learning can be combined to quickly derive joint photo-z PDFs to individual galaxies and their parent populations. Using the first 170 deg^2 of data from the ongoing Hyper Suprime-Cam survey, we demonstrate our method is able to generate accurate predictions and reliable credible intervals over ~370k high-quality redshifts. We then use galaxy-galaxy lensing to empirically validate our predicted photo-z's over ~14M objects, finding a robust signal.

  14. Outskirts of Local Group Dwarf Galaxies Revealed by Subaru Hyper Suprime-Cam

    NASA Astrophysics Data System (ADS)

    Komiyama, Yutaka

    2017-03-01

    Local Group galaxies are important targets since their stellar populations can be resolved, and their properties can be investigated in detail with the help of stellar evolutionary models. The newly-built instrument for the 8.2m Subaru Telescope, Hyper Suprime-Cam (HSC), which has a 1 Giga pixel CCD camera with 1.5 degrees field of view, is the best instrument for observing Local Group galaxies. We have carried out a survey for Local Group dwarf galaxies using HSC aiming to shed light on the outskirts of these galaxies. The survey covers target galaxies out beyond the tidal radii down to a depth unexplored by previous surveys. Thanks to the high spatial resolution and high sensitivity provided by the Subaru Telescope, we are able to investigate properties such as spatial distribution and stellar population from the very center of galaxies to the outskirts. In this article, I will show results for the dwarf irregular galaxy NGC 6822 and the dwarf spheroidal galaxy Ursa Minor.

  15. First On-Site Data Analysis System for Subaru/Suprime-Cam

    NASA Astrophysics Data System (ADS)

    Furusawa, Hisanori; Okura, Yuki; Mineo, Sogo; Takata, Tadafumi; Nakata, Fumiaki; Tanaka, Manobu; Katayama, Nobuhiko; Itoh, Ryosuke; Yasuda, Naoki; Miyazaki, Satoshi; Komiyama, Yutaka; Utsumi, Yousuke; Uchida, Tomohisa; Aihara, Hiroaki

    2011-03-01

    We developed an automated on-site quick analysis system for mosaic CCD data of Suprime-Cam, which is a wide-field camera mounted at the prime focus of the Subaru Telescope, Mauna Kea, Hawaii. The first version of the data-analysis system was constructed, and started to operate in general observations. This system is a new function of observing support at the Subaru Telescope to provide the Subaru user community with an automated on-site data evaluation, aiming at improvements of observers' productivity, especially in large imaging surveys. The new system assists the data evaluation tasks in observations by the continuous monitoring of the characteristics of every data frame during observations. The evaluation results and data frames processed by this system are also useful for reducing the data-processing time in a full analysis after an observation. The primary analysis functions implemented in the data-analysis system are composed of automated realtime analysis for data evaluation and on-demand analysis, which is executed upon request, including mosaicing analysis and flat making analysis. In data evaluation, which is controlled by the organizing software, the database keeps track of the analysis histories, as well as the evaluated values of data frames, including seeing and sky background levels; it also helps in the selection of frames for mosaicing and flat making analysis. We examined the system performance and confirmed an improvement in the data-processing time by a factor of 9 with the aid of distributed parallel data processing and on-memory data processing, which makes the automated data evaluation effective.

  16. Data mining of near-Earth asteroids in the Subaru Suprime-Cam archive

    NASA Astrophysics Data System (ADS)

    Vaduvescu, O.; Conovici, M.; Popescu, M.; Sonka, A.; Paraschiv, A.; Lacatus, D.; Tudorica, A.; Hudin, L.; Curelaru, L.; Inceu, V.; Zavoianu, D.; Cornea, R.; Toma, R.; Asher, D. J.; Hadnett, J.; Cheallaigh, L. Ó.

    2017-06-01

    As part of the EURONEAR project, almost 70,000 mosaic Suprime-Cam images taken between 1999 and 2013 were data mined for about 9,800 near Earth asteroids (NEAs) known by 2013 May. Using our PRECOVERY server and the "Find Subaru CCD" tool, we scrutinized 4,186 candidate CCD images possibly holding 518 NEAs. We found 113 NEAs as faint as V<25 magnitude, their positions being measured in 589 images using Astrometrica, then reported to the Minor Planet Center. Among them, 18 objects represent encounters of previously single opposition NEAs, their orbital arcs being extended by up to 10 years. In the second part of this work we searched for unknown NEAs in 78 sequences (780 CCD fields) of 4-5 mosaic images selected from the same Suprime-Cam archive and totaling 16.6 sq.deg, with the aim to assess the faint NEA distribution observable with an 8-m class survey. A total of 2,018 moving objects were measured, from which we identified 18 better NEA candidates. Using the R_c filter in good weather conditions, mostly dark time and sky directions slightly biased towards the ecliptic, at least one NEA could be discovered in every 1 sq.deg surveyed.

  17. The on-site quality-assurance system for Hyper Suprime-Cam: OSQAH

    NASA Astrophysics Data System (ADS)

    Furusawa, Hisanori; Koike, Michitaro; Takata, Tadafumi; Okura, Yuki; Miyatake, Hironao; Lupton, Robert H.; Bickerton, Steven; Price, Paul A.; Bosch, James; Yasuda, Naoki; Mineo, Sogo; Yamada, Yoshihiko; Miyazaki, Satoshi; Nakata, Fumiaki; Koshida, Shintaro; Komiyama, Yutaka; Utsumi, Yousuke; Kawanomoto, Satoshi; Jeschke, Eric; Noumaru, Junichi; Schubert, Kiaina; Iwata, Ikuru; Finet, Francois; Fujiyoshi, Takuya; Tajitsu, Akito; Terai, Tsuyoshi; Lee, Chien-Hsiu

    2018-01-01

    We have developed an automated quick data analysis system for data quality assurance (QA) for Hyper Suprime-Cam (HSC). The system was commissioned in 2012-2014, and has been offered for general observations, including the HSC Subaru Strategic Program, since 2014 March. The system provides observers with data quality information, such as seeing, sky background level, and sky transparency, based on quick analysis as data are acquired. Quick-look images and validation of image focus are also provided through an interactive web application. The system is responsible for the automatic extraction of QA information from acquired raw data into a database, to assist with observation planning, assess progress of all observing programs, and monitor long-term efficiency variations of the instrument and telescope. Enhancements of the system are being planned to facilitate final data analysis, to improve the HSC archive, and to provide legacy products for astronomical communities.

  18. Development of a Database System for Data Obtained by Hyper Suprime-Cam on the Subaru Telescope

    NASA Astrophysics Data System (ADS)

    Yamada, Y.; Takata, T.; Furusawa, H.; Okura, Y.; Koike, M.; Yamanoi, H.; Yasuda, N.; Bickerton, S.; Katayama, N.; Mineo, S.; Lupton, R.; Bosch, J.; Loomis, C.; Miyatake, H.; Price, P.; Smith, K.; Lang, D.

    2014-05-01

    We are developing a database system for the Hyper Suprime-Cam (HSC) data on the Subaru Telescope in preparation for the HSC Survey. Since HSC has a huge field of view (1.5 degree diameter), it will produce a huge amount of data. Here, we make a brief report on the prototype of our database.

  19. Minimoon Survey with Subaru Hyper Suprime-Cam

    NASA Astrophysics Data System (ADS)

    Jedicke, Robert; Boe, Ben; Bolin, Bryce T.; Bottke, William; Chyba, Monique; Denneau, Larry; Dodds, Curt; Granvik, Mikael; Kleyna, Jan; Weryk, Robert J.

    2017-10-01

    We will present the status of our search for minimoons using Hyper Suprime-Cam on the Subaru telescope on Maunkea, Hawaii. We use the term 'minimoon' to refer to objects that are gravitationally bound to the Earth-Moon system, make at least one revolution around the barycenter in a co-rotating frame relative to the Earth-Sun axis, and are within 3 Earth Hill-sphere radii (˜12 LD). There are one or two 1 to 2 meter diameter minimoons in the steady state population at any time, and about a dozen larger than 50 cm diameter. `Drifters' are also bound to the Earth-Moon system but make less than one revolution about the barycenter. The combined population of minimoons and drifters provide a new opportunity for scientific exploration of small asteroids and testing concepts for in-situ resource utilization. These objects provide interesting challenges for rendezvous missions because of their limited lifetime and complicated trajectories. Furthermore, they are difficult to detect because they are small, available for a limited time period, and move quickly across the sky.

  20. Proper motion of the Draco dwarf galaxy from Subaru Suprime-Cam data

    NASA Astrophysics Data System (ADS)

    Casetti-Dinescu, Dana I.; Girard, Terrence M.

    2016-09-01

    We have measured the absolute proper motion of the Draco dwarf spheroidal galaxy using Subaru Suprime-Cam images taken at three epochs, with time baselines of 4.4 and 7 yr. The magnitude limit of the proper-motion study is I = 25, thus allowing for thousands of background galaxies and Draco stars to be used to perform extensive astrometric tests and to derive the correction to an inertial reference frame. The derived proper motion is (μα, μδ) = (-0.284 ± 0.047, -0.289 ± 0.041) mas yr-1. This motion implies an orbit that takes Draco to a pericentre of ˜20 kpc; a somewhat disruptive orbit suggesting that tides might account for the rising velocity-dispersion profile of Draco seen in line-of-sight velocity studies. The orbit is only marginally consistent with Draco's membership to the vast polar structure of Galactic satellites, in contrast to a recent Hubble Space Telescope proper-motion measurement that finds alignment very likely. Our study is a test case to demonstrate that deep imaging with mosaic cameras of appropriate resolution can be used for high-accuracy, ground-based proper-motion measurement. As a useful by-product of the study, we also identify two faint brown-dwarf candidates in the foreground field.

  1. To the Galactic Virial Radius with Hyper Suprime-Cam

    NASA Astrophysics Data System (ADS)

    Deason, Alis J.; Belokurov, Vasily; Koposov, Sergey E.

    2018-01-01

    We exploit the exquisite, deep Hyper Suprime-Cam (HSC) imaging data to probe the Galactic halo out to 200 kpc. Using the ∼100 square degree, multiband photometry of the first HSC Wide survey data release, we identify blue horizontal branch (BHB) stars beyond 50 kpc in the halo. The presence of the Sagittarius (Sgr) stream in the HSC fields produces a notable excess of stars at the apocenter of the leading arm (∼50–60 kpc). For fields excluding Sgr, the BHB counts are consistent with a continuation of a ‑4 power law from the inner halo. However, we find that the majority of the non-Sgr BHB stars beyond 50 kpc reside in one 27 square degree HSC field called “VVDS.” Curiously, this field is located close to the Magellanic plane, and we hypothesize that the excess of stars between 50 and 200 kpc could be associated with distant Magellanic debris. Indeed, without the VVDS, there are very few BHBs in the remaining portions of the Galaxy probed by the HSC. Accordingly, this scarcity of tracers is consistent with a significant decline in stellar density beyond 50 kpc, with a power law of ‑4 or steeper.

  2. Metrology camera system of prime focus spectrograph for Suburu telescope

    NASA Astrophysics Data System (ADS)

    Wang, Shiang-Yu; Chou, Richard C. Y.; Huang, Pin-Jie; Ling, Hung-Hsu; Karr, Jennifer; Chang, Yin-Chang; Hu, Yen-Sang; Hsu, Shu-Fu; Chen, Hsin-Yo; Gunn, James E.; Reiley, Dan J.; Tamura, Naoyuki; Takato, Naruhisa; Shimono, Atsushi

    2016-08-01

    The Prime Focus Spectrograph (PFS) is a new optical/near-infrared multi-fiber spectrograph designed for the prime focus of the 8.2m Subaru telescope. PFS will cover a 1.3 degree diameter field with 2394 fibers to complement the imaging capabilities of Hyper SuprimeCam. To retain high throughput, the final positioning accuracy between the fibers and observing targets of PFS is required to be less than 10 microns. The metrology camera system (MCS) serves as the optical encoder of the fiber motors for the configuring of fibers. MCS provides the fiber positions within a 5 microns error over the 45 cm focal plane. The information from MCS will be fed into the fiber positioner control system for the closed loop control. MCS will be located at the Cassegrain focus of Subaru telescope in order to cover the whole focal plane with one 50M pixel Canon CMOS camera. It is a 380mm Schmidt type telescope which generates a uniform spot size with a 10 micron FWHM across the field for reasonable sampling of the point spread function. Carbon fiber tubes are used to provide a stable structure over the operating conditions without focus adjustments. The CMOS sensor can be read in 0.8s to reduce the overhead for the fiber configuration. The positions of all fibers can be obtained within 0.5s after the readout of the frame. This enables the overall fiber configuration to be less than 2 minutes. MCS will be installed inside a standard Subaru Cassgrain Box. All components that generate heat are located inside a glycol cooled cabinet to reduce the possible image motion due to heat. The optics and camera for MCS have been delivered and tested. The mechanical parts and supporting structure are ready as of spring 2016. The integration of MCS will start in the summer of 2016. In this report, the performance of the MCS components, the alignment and testing procedure as well as the status of the PFS MCS will be presented.

  3. Illuminating Low Surface Brightness Galaxies with the Hyper Suprime-Cam Survey

    NASA Astrophysics Data System (ADS)

    Greco, Johnny P.; Greene, Jenny E.; Strauss, Michael A.; Macarthur, Lauren A.; Flowers, Xzavier; Goulding, Andy D.; Huang, Song; Kim, Ji Hoon; Komiyama, Yutaka; Leauthaud, Alexie; Leisman, Lukas; Lupton, Robert H.; Sifón, Cristóbal; Wang, Shiang-Yu

    2018-04-01

    We present a catalog of extended low surface brightness galaxies (LSBGs) identified in the Wide layer of the Hyper Suprime-Cam Subaru Strategic Program (HSC-SSP). Using the first ∼200 deg2 of the survey, we have uncovered 781 LSBGs, spanning red (g ‑ i ≥ 0.64) and blue (g ‑ i < 0.64) colors and a wide range of morphologies. Since we focus on extended galaxies (r eff = 2.″5–14″), our sample is likely dominated by low-redshift objects. We define LSBGs to have mean surface brightnesses {\\bar{μ }}eff}(g)> 24.3 mag arcsec‑2, which allows nucleated galaxies into our sample. As a result, the central surface brightness distribution spans a wide range of μ 0(g) = 18–27.4 mag arcsec‑2, with 50% and 95% of galaxies fainter than 24.3 and 22 mag arcsec‑2, respectively. Furthermore, the surface brightness distribution is a strong function of color, with the red distribution being much broader and generally fainter than that of the blue LSBGs, and this trend shows a clear correlation with galaxy morphology. Red LSBGs typically have smooth light profiles that are well characterized by single-component Sérsic functions. In contrast, blue LSBGs tend to have irregular morphologies and show evidence for ongoing star formation. We cross-match our sample with existing optical, H I, and ultraviolet catalogs to gain insight into the physical nature of the LSBGs. We find that our sample is diverse, ranging from dwarf spheroidals and ultradiffuse galaxies in nearby groups to gas-rich irregulars to giant LSB spirals, demonstrating the potential of the HSC-SSP to provide a truly unprecedented view of the LSBG population.

  4. Status of the NectarCAM camera project

    NASA Astrophysics Data System (ADS)

    Glicenstein, J.-F.; Barcelo, M.; Barrio, J.-A.; Blanch, O.; Boix, J.; Bolmont, J.; Boutonnet, C.; Brun, P.; Chabanne, E.; Champion, C.; Colonges, S.; Corona, P.; Courty, B.; Delagnes, E.; Delgado, C.; Diaz, C.; Ernenwein, J.-P.; Fegan, S.; Ferreira, O.; Fesquet, M.; Fontaine, G.; Fouque, N.; Henault, F.; Gascón, D.; Giebels, B.; Herranz, D.; Hermel, R.; Hoffmann, D.; Horan, D.; Houles, J.; Jean, P.; Karkar, S.; Knödlseder, J.; Martinez, G.; Lamanna, G.; LeFlour, T.; Lévêque, A.; Lopez-Coto, R.; Louis, F.; Moudden, Y.; Moulin, E.; Nayman, P.; Nunio, F.; Olive, J.-F.; Panazol, J.-L.; Pavy, S.; Petrucci, P.-O.; Punch, M.; Prast, Julie; Ramon, P.; Rateau, S.; Ribó, M.; Rosier-Lees, S.; Sanuy, A.; Sizun, P.; Sieiro, J.; Sulanke, K.-H.; Tavernet, J.-P.; Tejedor, L. A.; Toussenel, F.; Vasileiadis, G.; Voisin, V.; Waegebert, V.; Zurbach, C.

    2014-07-01

    NectarCAM is a camera designed for the medium-sized telescopes of the Cherenkov Telescope Array (CTA) covering the central energy range 100 GeV to 30 TeV. It has a modular design based on the NECTAr chip, at the heart of which is a GHz sampling Switched Capacitor Array and 12-bit Analog to Digital converter. The camera will be equipped with 265 7-photomultiplier modules, covering a field of view of 7 to 8 degrees. Each module includes the photomultiplier bases, High Voltage supply, pre-amplifier, trigger, readout and Thernet transceiver. Events recorded last between a few nanoseconds and tens of nanoseconds. A flexible trigger scheme allows to read out very long events. NectarCAM can sustain a data rate of 10 kHz. The camera concept, the design and tests of the various subcomponents and results of thermal and electrical prototypes are presented. The design includes the mechanical structure, the cooling of electronics, read-out, clock distribution, slow control, data-acquisition, trigger, monitoring and services. A 133-pixel prototype with full scale mechanics, cooling, data acquisition and slow control will be built at the end of 2014.

  5. Effect of camera angulation on adaptation of CAD/CAM restorations.

    PubMed

    Parsell, D E; Anderson, B C; Livingston, H M; Rudd, J I; Tankersley, J D

    2000-01-01

    A significant concern with computer-assisted design/computer-assisted manufacturing (CAD/CAM)-produced prostheses is the accuracy of adaptation of the restoration to the preparation. The objective of this study is to determine the effect of operator-controlled camera misalignment on restoration adaptation. A CEREC 2 CAD/CAM unit (Sirona Dental Systems, Bensheim, Germany) was used to capture the optical impressions and machine the restorations. A Class I preparation was used as the standard preparation for optical impressions. Camera angles along the mesio-distal and buccolingual alignment were varied from the ideal orientation. Occlusal marginal gaps and sample height, width, and length were measured and compared to preparation dimensions. For clinical correlation, clinicians were asked to take optical impressions of mesio-occlusal preparations (Class II) on all four second molar sites, using a patient simulator. On the adjacent first molar occlusal surfaces, a preparation was machined such that camera angulation could be calculated from information taken from the optical impression. Degree of tilt and plane of tilt were compared to the optimum camera positions for those preparations. One-way analysis of variance and Dunnett C post hoc testing (alpha = 0.01) revealed little significant degradation in fit with camera angulation. Only the apical length fit was significantly degraded by excessive angulation. The CEREC 2 CAD/CAM system was found to be relatively insensitive to operator-induced errors attributable to camera misalignments of less than 5 degrees in either the buccolingual or the mesiodistal plane. The average camera tilt error generated by clinicians for all sites was 1.98 +/- 1.17 degrees.

  6. Photometric redshifts for Hyper Suprime-Cam Subaru Strategic Program Data Release 1

    NASA Astrophysics Data System (ADS)

    Tanaka, Masayuki; Coupon, Jean; Hsieh, Bau-Ching; Mineo, Sogo; Nishizawa, Atsushi J.; Speagle, Joshua; Furusawa, Hisanori; Miyazaki, Satoshi; Murayama, Hitoshi

    2018-01-01

    Photometric redshifts are a key component of many science objectives in the Hyper Suprime-Cam Subaru Strategic Program (HSC-SSP). In this paper, we describe and compare the codes used to compute photometric redshifts for HSC-SSP, how we calibrate them, and the typical accuracy we achieve with the HSC five-band photometry (grizy). We introduce a new point estimator based on an improved loss function and demonstrate that it works better than other commonly used estimators. We find that our photo-z's are most accurate at 0.2 ≲ zphot ≲ 1.5, where we can straddle the 4000 Å break. We achieve σ[Δzphot/(1 + zphot)] ˜ 0.05 and an outlier rate of about 15% for galaxies down to i = 25 within this redshift range. If we limit ourselves to a brighter sample of i < 24, we achieve σ ˜ 0.04 and ˜8% outliers. Our photo-z's should thus enable many science cases for HSC-SSP. We also characterize the accuracy of our redshift probability distribution function (PDF) and discover that some codes over-/underestimate the redshift uncertainties, which has implications for N(z) reconstruction. Our photo-z products for the entire area in Public Data Release 1 are publicly available, and both our catalog products (such as point estimates) and full PDFs can be retrieved from the data release site, "https://hsc-release.mtk.nao.ac.jp/".

  7. Multi-band photometry of trans-Neptunian objects in the Subaru Hyper Suprime-Cam survey

    NASA Astrophysics Data System (ADS)

    Terai, Tsuyoshi; Yoshida, Fumi; Ohtsuki, Keiji; Lykawka, Patryk Sofia; Takato, Naruhisa; Higuchi, Arika; Ito, Takashi; Komiyama, Yutaka; Miyazaki, Satoshi; Wang, Shiang-Yu

    2018-01-01

    We present visible multi-band photometry of trans-Neptunian objects (TNOs) observed by the Subaru Telescope in the framework of the Hyper Suprime-Cam Subaru Strategic Program (HSC-SSP) from 2014 March to 2016 September. We measured the five broad-band (g, r, i, z, and Y) colors over the wavelength range from 0.4 μm to 1.0 μm for 30 known TNOs using the HSC-SSP survey data covering ˜500 deg2 of sky within ±30° of ecliptic latitude. This dataset allows us to investigate the correlations between the dynamical classes and visible reflectance spectra of TNOs. Our results show that the hot classical and scattered populations with orbital inclination (I) of I ≳ 6° share similar color distributions, while the cold classical population with I ≲ 6° has a different color distribution from the others. The low-I population has reflectance increasing toward longer wavelengths up to ˜0.8 μm, with a steeper slope than the high-I population at ≲ 0.6 μm. We also find a significant anti-correlation between g - r/r - i colors and inclination in the high-I population, as well as a possible bimodality in the g - i color vs. eccentricity plot.

  8. First data release of the Hyper Suprime-Cam Subaru Strategic Program

    NASA Astrophysics Data System (ADS)

    Aihara, Hiroaki; Armstrong, Robert; Bickerton, Steven; Bosch, James; Coupon, Jean; Furusawa, Hisanori; Hayashi, Yusuke; Ikeda, Hiroyuki; Kamata, Yukiko; Karoji, Hiroshi; Kawanomoto, Satoshi; Koike, Michitaro; Komiyama, Yutaka; Lang, Dustin; Lupton, Robert H.; Mineo, Sogo; Miyatake, Hironao; Miyazaki, Satoshi; Morokuma, Tomoki; Obuchi, Yoshiyuki; Oishi, Yukie; Okura, Yuki; Price, Paul A.; Takata, Tadafumi; Tanaka, Manobu M.; Tanaka, Masayuki; Tanaka, Yoko; Uchida, Tomohisa; Uraguchi, Fumihiro; Utsumi, Yousuke; Wang, Shiang-Yu; Yamada, Yoshihiko; Yamanoi, Hitomi; Yasuda, Naoki; Arimoto, Nobuo; Chiba, Masashi; Finet, Francois; Fujimori, Hiroki; Fujimoto, Seiji; Furusawa, Junko; Goto, Tomotsugu; Goulding, Andy; Gunn, James E.; Harikane, Yuichi; Hattori, Takashi; Hayashi, Masao; Hełminiak, Krzysztof G.; Higuchi, Ryo; Hikage, Chiaki; Ho, Paul T. P.; Hsieh, Bau-Ching; Huang, Kuiyun; Huang, Song; Imanishi, Masatoshi; Iwata, Ikuru; Jaelani, Anton T.; Jian, Hung-Yu; Kashikawa, Nobunari; Katayama, Nobuhiko; Kojima, Takashi; Konno, Akira; Koshida, Shintaro; Kusakabe, Haruka; Leauthaud, Alexie; Lee, Chien-Hsiu; Lin, Lihwai; Lin, Yen-Ting; Mandelbaum, Rachel; Matsuoka, Yoshiki; Medezinski, Elinor; Miyama, Shoken; Momose, Rieko; More, Anupreeta; More, Surhud; Mukae, Shiro; Murata, Ryoma; Murayama, Hitoshi; Nagao, Tohru; Nakata, Fumiaki; Niida, Mana; Niikura, Hiroko; Nishizawa, Atsushi J.; Oguri, Masamune; Okabe, Nobuhiro; Ono, Yoshiaki; Onodera, Masato; Onoue, Masafusa; Ouchi, Masami; Pyo, Tae-Soo; Shibuya, Takatoshi; Shimasaku, Kazuhiro; Simet, Melanie; Speagle, Joshua; Spergel, David N.; Strauss, Michael A.; Sugahara, Yuma; Sugiyama, Naoshi; Suto, Yasushi; Suzuki, Nao; Tait, Philip J.; Takada, Masahiro; Terai, Tsuyoshi; Toba, Yoshiki; Turner, Edwin L.; Uchiyama, Hisakazu; Umetsu, Keiichi; Urata, Yuji; Usuda, Tomonori; Yeh, Sherry; Yuma, Suraphong

    2018-01-01

    The Hyper Suprime-Cam Subaru Strategic Program (HSC-SSP) is a three-layered imaging survey aimed at addressing some of the most important outstanding questions in astronomy today, including the nature of dark matter and dark energy. The survey has been awarded 300 nights of observing time at the Subaru Telescope, and it started in 2014 March. This paper presents the first public data release of HSC-SSP. This release includes data taken in the first 1.7 yr of observations (61.5 nights), and each of the Wide, Deep, and UltraDeep layers covers about 108, 26, and 4 square degrees down to depths of i ˜ 26.4, ˜26.5, and ˜27.0 mag, respectively (5 σ for point sources). All the layers are observed in five broad bands (grizy), and the Deep and UltraDeep layers are observed in narrow bands as well. We achieve an impressive image quality of 0{^''.}6 in the i band in the Wide layer. We show that we achieve 1%-2% point spread function (PSF) photometry (root mean square) both internally and externally (against Pan-STARRS1), and ˜10 mas and 40 mas internal and external astrometric accuracy, respectively. Both the calibrated images and catalogs are made available to the community through dedicated user interfaces and database servers. In addition to the pipeline products, we also provide value-added products such as photometric redshifts and a collection of public spectroscopic redshifts. Detailed descriptions of all the data can be found online. The data release website is https://hsc-release.mtk.nao.ac.jp.

  9. Status of the photomultiplier-based FlashCam camera for the Cherenkov Telescope Array

    NASA Astrophysics Data System (ADS)

    Pühlhofer, G.; Bauer, C.; Eisenkolb, F.; Florin, D.; Föhr, C.; Gadola, A.; Garrecht, F.; Hermann, G.; Jung, I.; Kalekin, O.; Kalkuhl, C.; Kasperek, J.; Kihm, T.; Koziol, J.; Lahmann, R.; Manalaysay, A.; Marszalek, A.; Rajda, P. J.; Reimer, O.; Romaszkan, W.; Rupinski, M.; Schanz, T.; Schwab, T.; Steiner, S.; Straumann, U.; Tenzer, C.; Vollhardt, A.; Weitzel, Q.; Winiarski, K.; Zietara, K.

    2014-07-01

    The FlashCam project is preparing a camera prototype around a fully digital FADC-based readout system, for the medium sized telescopes (MST) of the Cherenkov Telescope Array (CTA). The FlashCam design is the first fully digital readout system for Cherenkov cameras, based on commercial FADCs and FPGAs as key components for digitization and triggering, and a high performance camera server as back end. It provides the option to easily implement different types of trigger algorithms as well as digitization and readout scenarios using identical hardware, by simply changing the firmware on the FPGAs. The readout of the front end modules into the camera server is Ethernet-based using standard Ethernet switches and a custom, raw Ethernet protocol. In the current implementation of the system, data transfer and back end processing rates of 3.8 GB/s and 2.4 GB/s have been achieved, respectively. Together with the dead-time-free front end event buffering on the FPGAs, this permits the cameras to operate at trigger rates of up to several ten kHz. In the horizontal architecture of FlashCam, the photon detector plane (PDP), consisting of photon detectors, preamplifiers, high voltage-, control-, and monitoring systems, is a self-contained unit, mechanically detached from the front end modules. It interfaces to the digital readout system via analogue signal transmission. The horizontal integration of FlashCam is expected not only to be more cost efficient, it also allows PDPs with different types of photon detectors to be adapted to the FlashCam readout system. By now, a 144-pixel mini-camera" setup, fully equipped with photomultipliers, PDP electronics, and digitization/ trigger electronics, has been realized and extensively tested. Preparations for a full-scale, 1764 pixel camera mechanics and a cooling system are ongoing. The paper describes the status of the project.

  10. Subaru Hyper Suprime-Cam Survey for an optical counterpart of GW170817

    NASA Astrophysics Data System (ADS)

    Tominaga, Nozomu; Tanaka, Masaomi; Morokuma, Tomoki; Utsumi, Yousuke; Yamaguchi, Masaki S.; Yasuda, Naoki; Tanaka, Masayuki; Yoshida, Michitoshi; Fujiyoshi, Takuya; Furusawa, Hisanori; Kawabata, Koji S.; Lee, Chien-Hsiu; Motohara, Kentaro; Ohsawa, Ryou; Ohta, Kouji; Terai, Tsuyoshi; Abe, Fumio; Aoki, Wako; Asakura, Yuichiro; Barway, Sudhanshu; Bond, Ian A.; Fujisawa, Kenta; Honda, Satoshi; Ioka, Kunihito; Itoh, Youichi; Kawai, Nobuyuki; Kim, Ji Hoon; Koshimoto, Naoki; Matsubayashi, Kazuya; Miyazaki, Shota; Saito, Tomoki; Sekiguchi, Yuichiro; Sumi, Takahiro; Tristram, Paul J.

    2018-03-01

    We perform a z-band survey for an optical counterpart of the binary neutron star coalescence GW170817 with Subaru/Hyper Suprime-Cam. Our untargeted transient search covers 23.6 deg2 corresponding to the 56.6% credible region of GW170817 and reaches the 50% completeness magnitude of 20.6 mag on average. As a result, we find 60 candidate extragalactic transients, including J-GEM17btc (also known as SSS17a/DLT17ck). While J-GEM17btc is associated with NGC 4993, which is firmly located inside the 3D skymap of GW170817, the other 59 candidates do not have distance information in the GLADE v2 catalog or NASA/IPAC Extragalactic Database. Among 59 of the candidates, 58 are located at the center of extended objects in the Pan-STARRS1 catalog, while one candidate has an offset. We present location, z-band apparent magnitude, and time variability of the candidates and evaluate the probabilities that they are located within the 3D skymap of GW170817. The probability for J-GEM17btc is 64%, which is much higher than for the other 59 candidates (9.3 × 10-3-2.1 × 10-1%). Furthermore, the possibility that at least one of the other 59 candidates is located within the 3D skymap is only 3.2%. Therefore, we conclude that J-GEM17btc is the most likely and distinguished candidate to be the optical counterpart of GW170817.

  11. InfraCAM (trade mark): A Hand-Held Commercial Infrared Camera Modified for Spaceborne Applications

    NASA Technical Reports Server (NTRS)

    Manitakos, Daniel; Jones, Jeffrey; Melikian, Simon

    1996-01-01

    In 1994, Inframetrics introduced the InfraCAM(TM), a high resolution hand-held thermal imager. As the world's smallest, lightest and lowest power PtSi based infrared camera, the InfraCAM is ideal for a wise range of industrial, non destructive testing, surveillance and scientific applications. In addition to numerous commercial applications, the light weight and low power consumption of the InfraCAM make it extremely valuable for adaptation to space borne applications. Consequently, the InfraCAM has been selected by NASA Lewis Research Center (LeRC) in Cleveland, Ohio, for use as part of the DARTFire (Diffusive and Radiative Transport in Fires) space borne experiment. In this experiment, a solid fuel is ignited in a low gravity environment. The combustion period is recorded by both visible and infrared cameras. The infrared camera measures the emission from polymethyl methacrylate, (PMMA) and combustion products in six distinct narrow spectral bands. Four cameras successfully completed all qualification tests at Inframetrics and at NASA Lewis. They are presently being used for ground based testing in preparation for space flight in the fall of 1995.

  12. A New Milky Way Satellite Discovered in the Subaru/Hyper Suprime-Cam Survey

    NASA Astrophysics Data System (ADS)

    Homma, Daisuke; Chiba, Masashi; Okamoto, Sakurako; Komiyama, Yutaka; Tanaka, Masayuki; Tanaka, Mikito; Ishigaki, Miho N.; Akiyama, Masayuki; Arimoto, Nobuo; Garmilla, José A.; Lupton, Robert H.; Strauss, Michael A.; Furusawa, Hisanori; Miyazaki, Satoshi; Murayama, Hitoshi; Nishizawa, Atsushi J.; Takada, Masahiro; Usuda, Tomonori; Wang, Shiang-Yu

    2016-11-01

    We report the discovery of a new ultra-faint dwarf satellite companion of the Milky Way (MW) based on the early survey data from the Hyper Suprime-Cam Subaru Strategic Program. This new satellite, Virgo I, which is located in the constellation of Virgo, has been identified as a statistically significant (5.5σ) spatial overdensity of star-like objects with a well-defined main sequence and red giant branch in the color-magnitude diagram. The significance of this overdensity increases to 10.8σ when the relevant isochrone filter is adopted for the search. Based on the distribution of the stars around the likely main-sequence turnoff at r ˜ 24 mag, the distance to Virgo I is estimated as 87 kpc, and its most likely absolute magnitude calculated from a Monte Carlo analysis is M V = -0.8 ± 0.9 mag. This stellar system has an extended spatial distribution with a half-light radius of {38}-11+12 pc, which clearly distinguishes it from a globular cluster with comparable luminosity. Thus, Virgo I is one of the faintest dwarf satellites known and is located beyond the reach of the Sloan Digital Sky Survey. This demonstrates the power of this survey program to identify very faint dwarf satellites. This discovery of Virgo I is based only on about 100 square degrees of data, thus a large number of faint dwarf satellites are likely to exist in the outer halo of the MW.

  13. Hyper Suprime-Camera Survey of the Akari NEP Wide Field

    NASA Astrophysics Data System (ADS)

    Goto, Tomotsugu; Toba, Yoshiki; Utsumi, Yousuke; Oi, Nagisa; Takagi, Toshinobu; Malkan, Matt; Ohayma, Youichi; Murata, Kazumi; Price, Paul; Karouzos, Marios; Matsuhara, Hideo; Nakagawa, Takao; Wada, Takehiko; Serjeant, Steve; Burgarella, Denis; Buat, Veronique; Takada, Masahiro; Miyazaki, Satoshi; Oguri, Masamune; Miyaji, Takamitsu; Oyabu, Shinki; White, Glenn; Takeuchi, Tsutomu; Inami, Hanae; Perason, Chris; Malek, Katarzyna; Marchetti, Lucia; Lee, Hyung Mok; Im, Myung; Kim, Seong Jin; Koptelova, Ekaterina; Chao, Dani; Wu, Yi-Han; AKARI NEP Survey Team; AKARI All Sky Survey Team

    2017-03-01

    The extragalactic background suggests half the energy generated by stars was reprocessed into the infrared (IR) by dust. At z ∼1.3, 90% of star formation is obscured by dust. To fully understand the cosmic star formation history, it is critical to investigate infrared emission. AKARI has made deep mid-IR observation using its continuous 9-band filters in the NEP field (5.4 deg^2), using ∼10% of the entire pointed observations available throughout its lifetime. However, there remain 11,000 AKARI infrared sources undetected with the previous CFHT/Megacam imaging (r ∼25.9ABmag). Redshift and IR luminosity of these sources are unknown. These sources may contribute significantly to the cosmic star-formation rate density (CSFRD). For example, if they all lie at 1 < z < 2, the CSFRD will be twice as high at the epoch. We are carrying out deep imaging of the NEP field in 5 broad bands (g,r,i,z, and y) using Hyper Suprime-Camera (HSC), which has 1.5 deg field of view in diameter on Subaru 8m telescope. This will provide photometric redshift information, and thereby IR luminosity for the previously-undetected 11,000 faint AKARI IR sources. Combined with AKARI's mid-IR AGN/SF diagnosis, and accurate mid-IR luminosity measurement, this will allow a complete census of cosmic star-formation/AGN accretion history obscured by dust.

  14. QuadCam - A Quadruple Polarimetric Camera for Space Situational Awareness

    NASA Astrophysics Data System (ADS)

    Skuljan, J.

    A specialised quadruple polarimetric camera for space situational awareness, QuadCam, has been built at the Defence Technology Agency (DTA), New Zealand, as part of collaboration with the Defence Science and Technology Laboratory (Dstl), United Kingdom. The design was based on a similar system originally developed at Dstl, with some significant modifications for improved performance. The system is made up of four identical CCD cameras looking in the same direction, but in a different plane of polarisation at 0, 45, 90 and 135 degrees with respect to the reference plane. A standard set of Stokes parameters can be derived from the four images in order to describe the state of polarisation of an object captured in the field of view. The modified design of the DTA QuadCam makes use of four small Raspberry Pi computers, so that each camera is controlled by its own computer in order to speed up the readout process and ensure that the four individual frames are taken simultaneously (to within 100-200 microseconds). In addition, a new firmware was requested from the camera manufacturer so that an output signal is generated to indicate the state of the camera shutter. A specialised GPS unit (also developed at DTA) is then used to monitor the shutter signals from the four cameras and record the actual time of exposure to an accuracy of about 100 microseconds. This makes the system well suited for the observation of fast-moving objects in the low Earth orbit (LEO). The QuadCam is currently mounted on a Paramount MEII robotic telescope mount at the newly built DTA space situational awareness observatory located on Whangaparaoa Peninsula near Auckland, New Zealand. The system will be used for tracking satellites in low Earth orbit and geostationary belt as well. The performance of the camera has been evaluated and a series of test images have been collected in order to derive the polarimetric signatures for selected satellites.

  15. Galaxy Interactions and AGN-triggering to z~1: an unprecedented new view from the Hyper Suprime-Cam Survey

    NASA Astrophysics Data System (ADS)

    Goulding, Andy D.; Greene, Jenny E.; Bezanson, Rachel; Greco, Johnny; Johnson, Sean; Medezinski, Elinor; Strauss, Michael A.; HSC Collaboration

    2017-01-01

    Collisions and interactions between galaxies are thought to be pivotal stages in their formation and evolution, causing the rapid production of new stars, and may also serve as a mechanism for fueling supermassive black holes (BH). Harnessing the exquisite spatial resolution (0.3—0.7 arcsec) afforded by the new 1400 deg2 Hyper Suprime-Cam (HSC) Survey, we present our new constraints on the importance of major and minor mergers in growing BHs throughout the last ~7 Gyrs. Utilizing the first ~170 deg2 of the HSC Survey, and mid-infrared observations in the WISE All-Sky survey, we have robustly selected active galactic nuclei (AGN), starburst, and mass-matched control galaxy samples, totaling ~120,000 spectroscopically confirmed systems at i<22 mag. We identify galaxy interactions using a novel machine-learning technique, and use these data to map the growth of BHs as a function of interaction-stage, redshift and AGN luminosity, ultimately providing the necessary large-number statistics required to investigate merger—AGN triggering in the context of galaxy evolution out to z~1.

  16. Characterization and photometric performance of the Hyper Suprime-Cam Software Pipeline

    NASA Astrophysics Data System (ADS)

    Huang, Song; Leauthaud, Alexie; Murata, Ryoma; Bosch, James; Price, Paul; Lupton, Robert; Mandelbaum, Rachel; Lackner, Claire; Bickerton, Steven; Miyazaki, Satoshi; Coupon, Jean; Tanaka, Masayuki

    2018-01-01

    The Subaru Strategic Program (SSP) is an ambitious multi-band survey using the Hyper Suprime-Cam (HSC) on the Subaru telescope. The Wide layer of the SSP is both wide and deep, reaching a detection limit of i ˜ 26.0 mag. At these depths, it is challenging to achieve accurate, unbiased, and consistent photometry across all five bands. The HSC data are reduced using a pipeline that builds on the prototype pipeline for the Large Synoptic Survey Telescope. We have developed a Python-based, flexible framework to inject synthetic galaxies into real HSC images, called SynPipe. Here we explain the design and implementation of SynPipe and generate a sample of synthetic galaxies to examine the photometric performance of the HSC pipeline. For stars, we achieve 1% photometric precision at i ˜ 19.0 mag and 6% precision at i ˜ 25.0 in the i band (corresponding to statistical scatters of ˜0.01 and ˜0.06 mag respectively). For synthetic galaxies with single-Sérsic profiles, forced CModel photometry achieves 13% photometric precision at i ˜ 20.0 mag and 18% precision at i ˜ 25.0 in the i band (corresponding to statistical scatters of ˜0.15 and ˜0.22 mag respectively). We show that both forced point spread function and CModel photometry yield unbiased color estimates that are robust to seeing conditions. We identify several caveats that apply to the version of HSC pipeline used for the first public HSC data release (DR1) that need to be taking into consideration. First, the degree to which an object is blended with other objects impacts the overall photometric performance. This is especially true for point sources. Highly blended objects tend to have larger photometric uncertainties, systematically underestimated fluxes, and slightly biased colors. Secondly, >20% of stars at 22.5 < i < 25.0 mag can be misclassified as extended objects. Thirdly, the current CModel algorithm tends to strongly underestimate the half-light radius and ellipticity of galaxy with i > 21.5 mag.

  17. Performance verification of the FlashCam prototype camera for the Cherenkov Telescope Array

    NASA Astrophysics Data System (ADS)

    Werner, F.; Bauer, C.; Bernhard, S.; Capasso, M.; Diebold, S.; Eisenkolb, F.; Eschbach, S.; Florin, D.; Föhr, C.; Funk, S.; Gadola, A.; Garrecht, F.; Hermann, G.; Jung, I.; Kalekin, O.; Kalkuhl, C.; Kasperek, J.; Kihm, T.; Lahmann, R.; Marszalek, A.; Pfeifer, M.; Principe, G.; Pühlhofer, G.; Pürckhauer, S.; Rajda, P. J.; Reimer, O.; Santangelo, A.; Schanz, T.; Schwab, T.; Steiner, S.; Straumann, U.; Tenzer, C.; Vollhardt, A.; Wolf, D.; Zietara, K.; CTA Consortium

    2017-12-01

    The Cherenkov Telescope Array (CTA) is a future gamma-ray observatory that is planned to significantly improve upon the sensitivity and precision of the current generation of Cherenkov telescopes. The observatory will consist of several dozens of telescopes with different sizes and equipped with different types of cameras. Of these, the FlashCam camera system is the first to implement a fully digital signal processing chain which allows for a traceable, configurable trigger scheme and flexible signal reconstruction. As of autumn 2016, a prototype FlashCam camera for the medium-sized telescopes of CTA nears completion. First results of the ongoing system tests demonstrate that the signal chain and the readout system surpass CTA requirements. The stability of the system is shown using long-term temperature cycling.

  18. NectarCAM, a camera for the medium sized telescopes of the Cherenkov telescope array

    NASA Astrophysics Data System (ADS)

    Glicenstein, J.-F.; Shayduk, M.

    2017-01-01

    NectarCAM is a camera proposed for the medium-sized telescopes of the Cherenkov Telescope Array (CTA) which covers the core energy range of 100 GeV to 30 TeV. It has a modular design and is based on the NECTAr chip, at the heart of which is a GHz sampling Switched Capacitor Array and 12-bit Analog to Digital converter. The camera will be equipped with 265 7-photomultiplier modules, covering a field of view of 8 degrees. Each module includes photomultiplier bases, high voltage supply, pre-amplifier, trigger, readout and Ethernet transceiver. The recorded events last between a few nanoseconds and tens of nanoseconds. The expected performance of the camera are discussed. Prototypes of NectarCAM components have been built to validate the design. Preliminary results of a 19-module mini-camera are presented, as well as future plans for building and testing a full size camera.

  19. STAR FORMATION AT 4 < z < 6 FROM THE SPITZER LARGE AREA SURVEY WITH HYPER-SUPRIME-CAM (SPLASH)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steinhardt, Charles L.; Capak, Peter; Masters, Dan

    2014-08-20

    Using the first 50% of data collected for the Spitzer Large Area Survey with Hyper-Suprime-Cam observations on the 1.8 deg{sup 2} Cosmological Evolution Survey we estimate the masses and star formation rates of 3398 M {sub *} > 10{sup 10} M {sub ☉} star-forming galaxies at 4 < z < 6 with a substantial population up to M {sub *} ≳ 10{sup 11.5} M {sub ☉}. We find that the strong correlation between stellar mass and star formation rate seen at lower redshift (the ''main sequence'' of star-forming galaxies) extends to z ∼ 6. The observed relation and scatter is consistentmore » with a continued increase in star formation rate at fixed mass in line with extrapolations from lower-redshift observations. It is difficult to explain this continued correlation, especially for the most massive systems, unless the most massive galaxies are forming stars near their Eddington-limited rate from their first collapse. Furthermore, we find no evidence for moderate quenching at higher masses, indicating quenching either has not occurred prior to z ∼ 6 or else occurs rapidly, so that few galaxies are visible in transition between star-forming and quenched.« less

  20. Star/Galaxy Separation in Hyper Suprime-Cam and Mapping the Milky Way with Star Counts

    NASA Astrophysics Data System (ADS)

    Garmilla, Jose Antonio

    We study the problem of separating stars and galaxies in the Hyper Suprime-Cam (HSC) multi-band imaging data at high galactic latitudes. We show that the current separation technique implemented in the HSC pipeline is unable to produce samples of stars with i 24 without a significant contamination from galaxies (> 50%). We study various methods for measuring extendedness in HSC with simulated and real data and find that there are a number of available techniques that give nearly optimal results; the extendedness measure HSC is currently using is among these. We develop a star/galaxy separation method for HSC based on the Extreme Deconvolution (XD) algorithm that uses colors and extendedness simultaneously, and show that with it we can generate samples of faint stars keeping contamination from galaxies under control to i ≤ 25. We apply our star/galaxy separation method to carry out a preliminary study of the structure of the Milky Way (MW) with main sequence (MS) stars using photometric parallax relations derived for the HSC photometric system. We show that it will be possible to generate a tomography of the MW stellar halo to galactocentric radii ˜ 100 kpc with ˜ 106 MS stars in the HSC Wide layer once the survey has been completed. We report two potential detections of the Sagittarius tidal stream with MS stars in the XMM and GAMA15 fields at ≈ 20 kpc and ≈ 40 kpc respectively.

  1. Population gradient in the Sextans dSph: comprehensive mapping of a dwarf galaxy by Suprime-Cam

    NASA Astrophysics Data System (ADS)

    Okamoto, S.; Arimoto, N.; Tolstoy, E.; Jablonka, P.; Irwin, M. J.; Komiyama, Y.; Yamada, Y.; Onodera, M.

    2017-05-01

    We present the deep and wide V and Ic photometry of the Sextans dwarf spheroidal galaxy (dSph) taken by the Suprime-Cam imager on the Subaru Telescope, which extends out to the tidal radius. The colour-magnitude diagram (CMD) reaches two magnitudes below the main-sequence (MS) turn-off, showing a steep red giant branch, a blue and a red horizontal branch (BHB and RHB, respectively), a sub-giant branch (SGB), an MS and blue stragglers (BSs). We construct the radial profile of each evolutionary phase and demonstrate that blue HB stars are more spatially extended, while red HB stars are more centrally concentrated than the other components. The colour distribution of SGB stars also varies with the galactocentric distance; the inner SGB stars shift bluer than those in the outskirts. The radial differences in the CMD morphology indicate the existence of the age gradient. The relatively younger stars (˜10 Gyr) are more centrally concentrated than the older ones (˜13 Gyr). The spatial contour maps of stars in different age bins also show that the younger population has a higher concentration and higher ellipticity than the older one. We also detect the centrally concentrated bright BS stars, the number of which is consistent with the idea that a part of these stars belongs to the remnant of a disrupted star cluster discovered in the previous spectroscopic studies.

  2. Minor Contribution of Quasars to Ionizing Photon Budget at z ˜ 6: Update on Quasar Luminosity Function at the Faint End with Subaru/Suprime-Cam

    NASA Astrophysics Data System (ADS)

    Onoue, Masafusa; Kashikawa, Nobunari; Willott, Chris J.; Hibon, Pascale; Im, Myungshin; Furusawa, Hisanori; Harikane, Yuichi; Imanishi, Masatoshi; Ishikawa, Shogo; Kikuta, Satoshi; Matsuoka, Yoshiki; Nagao, Tohru; Niino, Yuu; Ono, Yoshiaki; Ouchi, Masami; Tanaka, Masayuki; Tang, Ji-Jia; Toshikawa, Jun; Uchiyama, Hisakazu

    2017-10-01

    We constrain the quasar contribution to the cosmic reionization based on our deep optical survey of z ˜ 6 quasars down to z R = 24.15 using Subaru/Suprime-Cam in three UKIDSS-DXS fields covering 6.5 deg2. In Kashikawa et al. (2015), we select 17 quasar candidates and report our initial discovery of two low-luminosity quasars ({M}1450˜ -23) from seven targets, one of which might be a Lyα-emitting galaxy. From an additional optical spectroscopy, none of the four candidates out of the remaining 10 turn out to be genuine quasars. Moreover, the deeper optical photometry provided by the Hyper Suprime-Cam Subaru Strategic Program (HSC-SSP) shows that, unlike the two already-known quasars, the I - z and z - y colors of the last six candidates are consistent with M- or L-type brown dwarfs. Therefore, the quasar luminosity function (QLF) measurement in the previous paper is confirmed. Compiling the QLF measurements from the literature over a wide magnitude range, including an extremely faint AGN candidate from Parsa et al. (2017), to fit them with a double power law, we find that the best-fit faint-end slope is α =-{2.04}-0.18+0.33 (-{1.98}-0.21+0.48) and characteristic magnitude is {M}1450* =-{25.8}-1.9+1.1 (-{25.7}-1.8+1.0) in the case of two (one) quasar detection. Our result suggests that, if the QLF is integrated down to {M}1450=-18, quasars produce ˜1%-12% of the ionizing photons required to fully ionize the universe at z ˜ 6 with a 2σ confidence level, assuming that the escape fraction is {f}{esc}=1 and the intergalactic medium clumpy factor is C = 3. Even when the systematic uncertainties are taken into account, our result supports the scenario that quasars are the minor contributors of the reionization.

  3. A Subaru/Suprime-Cam wide-field survey of globular cluster populations around M87 - I. Observation, data analysis and luminosity function

    NASA Astrophysics Data System (ADS)

    Tamura, Naoyuki; Sharples, Ray M.; Arimoto, Nobuo; Onodera, Masato; Ohta, Kouji; Yamada, Yoshihiko

    2006-12-01

    In this paper and a companion paper, we report on a wide-field imaging survey of the globular cluster (GC) populations around M87 carried out with Suprime-Cam on the 8.2-m Subaru telescope. Here, we describe the observations, data reduction and data analysis, and present luminosity functions of GC populations around M87 and NGC 4552, another luminous Virgo elliptical in our survey field. The imaging data were taken in the B, V and I bands with a sky coverage of extending from the M87 centre out to ~0.5 Mpc. GC candidates were selected by applying a colour criterion on the B - V and V - I diagram to unresolved objects, which greatly reduces contamination. The data from control fields taken with Subaru/Suprime-Cam were also analysed for subtraction of contamination in the GC sample. These control field data are compatible with those in the M87 field in terms of the filter set (BVI), limiting magnitudes and image quality, which minimize the possibility of introducing any systematic errors into the subtractive correction. We investigate GC luminosity functions (GCLFs) at distances <= 10 arcmin (<~45 kpc) from the host galaxy centre in detail. By fitting Gaussians to the GCLFs, the V-band turnover magnitude (VTO) is estimated to be 23.62 +/- 0.06 and 23.56 +/- 0.20 mag for the GC population in M87 and NGC 4552, respectively. The GCLF is found to be a function of GC colour; VTO of the red GC subpopulation (V - I > 1.1) is fainter than that of the blue GC subpopulation (V - I <= 1.1) in both M87 and NGC 4552, as expected if the colour differences are primarily due to a metallicity effect, and the mass functions of the two subpopulations are similar. The radial dependence of the GCLF is also investigated for the GC population in M87. The GCLF of each subpopulation at 1 <= R <= 5 arcmin is compared to that at 5 <= R <= 10arcmin, but no significant trend with distance is found in the shape of the GCLF. We also estimate GC-specific frequencies (SN) for M87 and NGC 4552. The

  4. Resolved Stellar Streams around NGC 4631 from a Subaru/Hyper Suprime-Cam Survey

    NASA Astrophysics Data System (ADS)

    Tanaka, Mikito; Chiba, Masashi; Komiyama, Yutaka

    2017-06-01

    We present the first results of the Subaru/Hyper Suprime-Cam survey of the interacting galaxy system, NGC 4631 and NGC 4656. From the maps of resolved stellar populations, we identify 11 dwarf galaxies (including already-known dwarfs) in the outer region of NGC 4631 and the two tidal stellar streams around NGC 4631, named Stream SE and Stream NW, respectively. This paper describes the fundamental properties of these tidal streams. Based on the tip of the red giant branch method and the Bayesian statistics, we find that Stream SE (7.10 Mpc in expected a posteriori, EAP, with 90% credible intervals of [6.22, 7.29] Mpc) and Stream NW (7.91 Mpc in EAP with 90% credible intervals of [6.44, 7.97] Mpc) are located in front of and behind NGC 4631, respectively. We also calculate the metallicity distribution of stellar streams by comparing the member stars with theoretical isochrones on the color-magnitude diagram. We find that both streams have the same stellar population based on the Bayesian model selection method, suggesting that they originated from a tidal interaction between NGC 4631 and a single dwarf satellite. The expected progenitor has a positively skewed metallicity distribution function with {[M/H]}{EAP}=-0.92, with 90% credible intervals of [-1.46, -0.51]. The stellar mass of the progenitor is estimated as 3.7× {10}8 {M}⊙ , with 90% credible intervals of [5.8× {10}6,8.6× {10}9] {M}⊙ based on the mass-metallicity relation for Local group dwarf galaxies. This is in good agreement with the initial stellar mass of the progenitor that was presumed in the previous N-body simulation.

  5. Source selection for cluster weak lensing measurements in the Hyper Suprime-Cam survey

    NASA Astrophysics Data System (ADS)

    Medezinski, Elinor; Oguri, Masamune; Nishizawa, Atsushi J.; Speagle, Joshua S.; Miyatake, Hironao; Umetsu, Keiichi; Leauthaud, Alexie; Murata, Ryoma; Mandelbaum, Rachel; Sifón, Cristóbal; Strauss, Michael A.; Huang, Song; Simet, Melanie; Okabe, Nobuhiro; Tanaka, Masayuki; Komiyama, Yutaka

    2018-03-01

    We present optimized source galaxy selection schemes for measuring cluster weak lensing (WL) mass profiles unaffected by cluster member dilution from the Subaru Hyper Suprime-Cam Strategic Survey Program (HSC-SSP). The ongoing HSC-SSP survey will uncover thousands of galaxy clusters to z ≲ 1.5. In deriving cluster masses via WL, a critical source of systematics is contamination and dilution of the lensing signal by cluster members, and by foreground galaxies whose photometric redshifts are biased. Using the first-year CAMIRA catalog of ˜900 clusters with richness larger than 20 found in ˜140 deg2 of HSC-SSP data, we devise and compare several source selection methods, including selection in color-color space (CC-cut), and selection of robust photometric redshifts by applying constraints on their cumulative probability distribution function (P-cut). We examine the dependence of the contamination on the chosen limits adopted for each method. Using the proper limits, these methods give mass profiles with minimal dilution in agreement with one another. We find that not adopting either the CC-cut or P-cut methods results in an underestimation of the total cluster mass (13% ± 4%) and the concentration of the profile (24% ± 11%). The level of cluster contamination can reach as high as ˜10% at R ≈ 0.24 Mpc/h for low-z clusters without cuts, while employing either the P-cut or CC-cut results in cluster contamination consistent with zero to within the 0.5% uncertainties. Our robust methods yield a ˜60 σ detection of the stacked CAMIRA surface mass density profile, with a mean mass of M200c = [1.67 ± 0.05(stat)] × 1014 M⊙/h.

  6. Imaging Extended Emission-Line Regions of Obscured AGN with the Subaru Hyper Suprime-Cam Survey

    NASA Astrophysics Data System (ADS)

    Sun, Ai-Lei; Greene, Jenny E.; Zakamska, Nadia L.; Goulding, Andy; Strauss, Michael A.; Huang, Song; Johnson, Sean; Kawaguchi, Toshihiro; Matsuoka, Yoshiki; Marsteller, Alisabeth A.; Nagao, Tohru; Toba, Yoshiki

    2018-05-01

    Narrow-line regions excited by active galactic nuclei (AGN) are important for studying AGN photoionization and feedback. Their strong [O III] lines can be detected with broadband images, allowing morphological studies of these systems with large-area imaging surveys. We develop a new broad-band imaging technique to reconstruct the images of the [O III] line using the Subaru Hyper Suprime-Cam (HSC) Survey aided with spectra from the Sloan Digital Sky Survey (SDSS). The technique involves a careful subtraction of the galactic continuum to isolate emission from the [O III]λ5007 and [O III]λ4959 lines. Compared to traditional targeted observations, this technique is more efficient at covering larger samples without dedicated observational resources. We apply this technique to an SDSS spectroscopically selected sample of 300 obscured AGN at redshifts 0.1 - 0.7, uncovering extended emission-line region candidates with sizes up to tens of kpc. With the largest sample of uniformly derived narrow-line region sizes, we revisit the narrow-line region size - luminosity relation. The area and radii of the [O III] emission-line regions are strongly correlated with the AGN luminosity inferred from the mid-infrared (15 μm rest-frame) with a power-law slope of 0.62^{+0.05}_{-0.06}± 0.10 (statistical and systematic errors), consistent with previous spectroscopic findings. We discuss the implications for the physics of AGN emission-line regions and future applications of this technique, which should be useful for current and next-generation imaging surveys to study AGN photoionization and feedback with large statistical samples.

  7. A Spectroscopically Confirmed Double Source Plane Lens System in the Hyper Suprime-Cam Subaru Strategic Program

    NASA Astrophysics Data System (ADS)

    Tanaka, Masayuki; Wong, Kenneth C.; More, Anupreeta; Dezuka, Arsha; Egami, Eiichi; Oguri, Masamune; Suyu, Sherry H.; Sonnenfeld, Alessandro; Higuchi, Ryo; Komiyama, Yutaka; Miyazaki, Satoshi; Onoue, Masafusa; Oyamada, Shuri; Utsumi, Yousuke

    2016-08-01

    We report the serendipitous discovery of HSC J142449-005322, a double source plane lens system in the Hyper Suprime-Cam Subaru Strategic Program. We dub the system Eye of Horus. The lens galaxy is a very massive early-type galaxy with stellar mass of ˜ 7× {10}11 {M}⊙ located at {z}{{L}}=0.795. The system exhibits two arcs/rings with clearly different colors, including several knots. We have performed spectroscopic follow-up observations of the system with FIRE on Magellan. The outer ring is confirmed at {z}{{S}2}=1.988 with multiple emission lines, while the inner arc and counterimage is confirmed at {z}{{S}1}=1.302. This makes it the first double source plane system with spectroscopic redshifts of both sources. Interestingly, redshifts of two of the knots embedded in the outer ring are found to be offset by {{Δ }}z=0.002 from the other knots, suggesting that the outer ring consists of at least two distinct components in the source plane. We perform lens modeling with two independent codes and successfully reproduce the main features of the system. However, two of the lensed sources separated by ˜0.7 arcsec cannot be reproduced by a smooth potential, and the addition of substructure to the lens potential is required to reproduce them. Higher-resolution imaging of the system will help decipher the origin of this lensing feature and potentially detect the substructure.

  8. The quasar luminosity function at redshift 4 with the Hyper Suprime-Cam Wide Survey

    NASA Astrophysics Data System (ADS)

    Akiyama, Masayuki; He, Wanqiu; Ikeda, Hiroyuki; Niida, Mana; Nagao, Tohru; Bosch, James; Coupon, Jean; Enoki, Motohiro; Imanishi, Masatoshi; Kashikawa, Nobunari; Kawaguchi, Toshihiro; Komiyama, Yutaka; Lee, Chien-Hsiu; Matsuoka, Yoshiki; Miyazaki, Satoshi; Nishizawa, Atsushi J.; Oguri, Masamune; Ono, Yoshiaki; Onoue, Masafusa; Ouchi, Masami; Schulze, Andreas; Silverman, John D.; Tanaka, Manobu M.; Tanaka, Masayuki; Terashima, Yuichi; Toba, Yoshiki; Ueda, Yoshihiro

    2018-01-01

    We present the luminosity function of z ˜ 4 quasars based on the Hyper Suprime-Cam Subaru Strategic Program Wide layer imaging data in the g, r, i, z, and y bands covering 339.8 deg2. From stellar objects, 1666 z ˜ 4 quasar candidates are selected via the g-dropout selection down to i = 24.0 mag. Their photometric redshifts cover the redshift range between 3.6 and 4.3, with an average of 3.9. In combination with the quasar sample from the Sloan Digital Sky Survey in the same redshift range, a quasar luminosity function covering the wide luminosity range of M1450 = -22 to -29 mag is constructed. The quasar luminosity function is well described by a double power-law model with a knee at M1450 = -25.36 ± 0.13 mag and a flat faint-end slope with a power-law index of -1.30 ± 0.05. The knee and faint-end slope show no clear evidence of redshift evolution from those seen at z ˜ 2. The flat slope implies that the UV luminosity density of the quasar population is dominated by the quasars around the knee, and does not support the steeper faint-end slope at higher redshifts reported at z > 5. If we convert the M1450 luminosity function to the hard X-ray 2-10 keV luminosity function using the relation between the UV and X-ray luminosity of quasars and its scatter, the number density of UV-selected quasars matches well with that of the X-ray-selected active galactic nuclei (AGNs) above the knee of the luminosity function. Below the knee, the UV-selected quasars show a deficiency compared to the hard X-ray luminosity function. The deficiency can be explained by the lack of obscured AGNs among the UV-selected quasars.

  9. A Hyper Suprime-Cam View of the Interacting Galaxies of the M81 Group

    NASA Astrophysics Data System (ADS)

    Okamoto, Sakurako; Arimoto, Nobuo; Ferguson, Annette M. N.; Bernard, Edouard J.; Irwin, Mike J.; Yamada, Yoshihiko; Utsumi, Yousuke

    2015-08-01

    We present the first results of a wide-field mapping survey of the M81 group conducted with Hyper Suprime-Cam on the Subaru Telescope. Our deep photometry reaches ˜2 mag below the tip of the red giant branch (RGB) and reveals the spatial distribution of both old and young stars over an area of ˜ 100 × 115 kpc at the distance of M81. The young stars (˜30-160 Myr old) closely follow the neutral hydrogen distribution and can be found in a stellar stream between M81 and NGC 3077 and in numerous outlying stellar associations, including the known concentrations of Arp's Loop, Holmberg IX, an arc in the halo of M82, BK3N, and the Garland. Many of these groupings do not have counterparts in the RGB maps, suggesting they may be genuinely young systems. Our survey also reveals for the first time the very extended (≥slant 2× {R}25) halos of RGB stars around M81, M82, and NGC 3077, as well as faint tidal streams that link these systems. The halos of M82 and NGC 3077 exhibit highly disturbed morphologies, presumably a consequence of the recent gravitational encounter and their ongoing disruption. While the halos of M81 and NGC 3077 and the inner halo of M82 have similar {(g-i)}0 colors, the outer halo of M82 is significantly bluer indicating it is more metal poor. Remarkably, our deep panoramic view of the M81 group demonstrates that the complexity long known to be present in HI is equally matched in the low surface brightness stellar component. Based on data collected at Subaru Telescope, which is operated by the National Astronomical Observatory of Japan.

  10. Probabilistic Selection of High-redshfit Quasars with Subaru / Hyper Suprime-Cam Survey

    NASA Astrophysics Data System (ADS)

    Onoue, Masafusa

    2015-08-01

    High-redshift quasrs are an important probe of the distant Universe. They enable observational studies of the early growth of supermassive blackholes, cosmic reionization, chemical enrichment of host galaxies, and so on. We are now starting a new ground-breaking survey of high-redsfhit quasars (z>6) using the exquisite imaging data provided by the Hyper Suprime-Cam (HSC) Subaru Strategic Program (SSP) Survey. With the extremely wide-area coverage and high sensitivity thorugh five optical bands (1,400 deg2 to the depth of r~26 in Wide layer), it is one of the most powerful contemporary surveys that makes it possible for the HSC-AGN collaboration to increase the number of z>6 quasars by almost an order of magnitude, i.e., 300 at z~6 and 50 at z~7 based on the current estimate of the QLF at z>6 (Willott et al. 2010).One of the biggest challenges in the candidate selection is the significant contamination of Galactic brown dwarfs, which have the same point-like appearance as and similarly red colors to z>6 quasars. To overcome this issue, we have developed template SED fitting method optimized to high-redshift quasars selection for constructing the largest z>6 quasar sample with the HSC survey. Since 500 deg2 of the footprints of the HSC survey overlaps with the VISTA/VIKING survey, it is expected that z>6 quasars, with characteristic large Lyman break and flat red-continuum in its SED, can be separated out from contaminating sources by applying SED fitting with multi-wavelength photometric data. In practice, its application with 27 photometric bands to the COSMOS quasars at 36 quasar search with the first-year data products of the HSC survey, which results in extracting several promising candidates

  11. X-ray-bright optically faint active galactic nuclei in the Subaru Hyper Suprime-Cam wide survey

    NASA Astrophysics Data System (ADS)

    Terashima, Yuichi; Suganuma, Makoto; Akiyama, Masayuki; Greene, Jenny E.; Kawaguchi, Toshihiro; Iwasawa, Kazushi; Nagao, Tohru; Noda, Hirofumi; Toba, Yoshiki; Ueda, Yoshihiro; Yamashita, Takuji

    2018-01-01

    We construct a sample of X-ray-bright optically faint active galactic nuclei by combining Subaru Hyper Suprime-Cam, XMM-Newton, and infrared source catalogs. Fifty-three X-ray sources satisfying i-band magnitude fainter than 23.5 mag and X-ray counts with the EPIC-PN detector larger than 70 are selected from 9.1 deg2, and their spectral energy distributions (SEDs) and X-ray spectra are analyzed. Forty-four objects with an X-ray to i-band flux ratio FX/Fi > 10 are classified as extreme X-ray-to-optical flux sources. Spectral energy distributions of 48 among 53 are represented by templates of type 2 AGNs or star-forming galaxies and show the optical signature of stellar emission from host galaxies in the source rest frame. Infrared/optical SEDs indicate a significant contribution of emission from dust to the infrared fluxes, and that the central AGN is dust obscured. The photometric redshifts determined from the SEDs are in the range of 0.6-2.5. The X-ray spectra are fitted by an absorbed power-law model, and the intrinsic absorption column densities are modest (best-fit log NH = 20.5-23.5 cm-2 in most cases). The absorption-corrected X-ray luminosities are in the range of 6 × 1042-2 × 1045 erg s-1. Twenty objects are classified as type 2 quasars based on X-ray luminsosity and NH. The optical faintness is explained by a combination of redshifts (mostly z > 1.0), strong dust extinction, and in part a large ratio of dust/gas.

  12. Deep Subaru Hyper Suprime-Cam Observations of Milky Way Satellites Columba I and Triangulum II

    NASA Astrophysics Data System (ADS)

    Carlin, Jeffrey L.; Sand, David J.; Muñoz, Ricardo R.; Spekkens, Kristine; Willman, Beth; Crnojević, Denija; Forbes, Duncan A.; Hargis, Jonathan; Kirby, Evan; Peter, Annika H. G.; Romanowsky, Aaron J.; Strader, Jay

    2017-12-01

    We present deep, wide-field Subaru Hyper Suprime-Cam photometry of two recently discovered satellites of the Milky Way (MW): Columba I (Col I) and Triangulum II (Tri II). The color-magnitude diagrams of both objects point to exclusively old and metal-poor stellar populations. We re-derive structural parameters and luminosities of these satellites, and find {M}{{V},{Col}{{I}}}=-4.2+/- 0.2 for Col I and {M}{{V},{Tri}{II}}=-1.2+/- 0.4 for Tri II, with corresponding half-light radii of {r}{{h},{Col}{{I}}}=117+/- 17 pc and {r}{{h},{Tri}{II}}=21+/- 4 pc. The properties of both systems are consistent with observed scaling relations for MW dwarf galaxies. Based on archival data, we derive upper limits on the neutral gas content of these dwarfs, and find that they lack H I, as do the majority of observed satellites within the MW virial radius. Neither satellite shows evidence of tidal stripping in the form of extensions or distortions in matched-filter stellar density maps or surface-density profiles. However, the smaller Tri II system is relatively metal-rich for its luminosity (compared to other MW satellites), possibly because it has been tidally stripped. Through a suite of orbit simulations, we show that Tri II is approaching pericenter of its eccentric orbit, a stage at which tidal debris is unlikely to be seen. In addition, we find that Tri II may be on its first infall into the MW, which helps explain its unique properties among MW dwarfs. Further evidence that Tri II is likely an ultra-faint dwarf comes from its stellar mass function, which is similar to those of other MW dwarfs. Based in part on data collected at the Subaru Telescope, which is operated by the National Astronomical Observatory of Japan.

  13. PreCam Survey Work at ANL

    Science.gov Websites

    - Astrophysics - DES - PreCam PreCam Work at ANL The Argonne/HEP Dark Energy Survey (DES) group, working on the Dark Energy Camera (DECam), built a mini-DECam camera called PreCam. This camera has provided valuable

  14. Galaxy interactions trigger rapid black hole growth: An unprecedented view from the Hyper Suprime-Cam survey

    NASA Astrophysics Data System (ADS)

    Goulding, Andy D.; Greene, Jenny E.; Bezanson, Rachel; Greco, Johnny; Johnson, Sean; Leauthaud, Alexie; Matsuoka, Yoshiki; Medezinski, Elinor; Price-Whelan, Adrian M.

    2018-01-01

    Collisions and interactions between gas-rich galaxies are thought to be pivotal stages in their formation and evolution, causing the rapid production of new stars, and possibly serving as a mechanism for fueling supermassive black holes (BHs). Harnessing the exquisite spatial resolution (˜0{^''.}5) afforded by the first ˜170 deg2 of the Hyper Suprime-Cam (HSC) survey, we present our new constraints on the importance of galaxy-galaxy major mergers (1 : 4) in growing BHs throughout the last ˜8 Gyr. Utilizing mid-infrared observations in the WISE all-sky survey, we robustly select active galactic nuclei (AGN) and mass-matched control galaxy samples, totaling ˜140000 spectroscopically confirmed systems at i < 22 mag. We identify galaxy interaction signatures using a novel machine-learning random forest decision tree technique allowing us to select statistically significant samples of major mergers, minor mergers / irregular systems, and non-interacting galaxies. We use these samples to show that galaxies undergoing mergers are a factor of ˜2-7 more likely to contain luminous obscured AGN than non-interacting galaxies, and this is independent of both stellar mass and redshift to z < 0.9. Furthermore, based on our comparison of AGN fractions in mass-matched samples, we determine that the most luminous AGN population (LAGN ≳ 1045 erg s-1) systematically reside in merging systems over non-interacting galaxies. Our findings show that galaxy-galaxy interactions do, on average, trigger luminous AGN activity substantially more often than in secularly evolving non-interacting galaxies, and we further suggest that the BH growth rate may be closely tied to the dynamical time of the merger system.

  15. A large sample of shear-selected clusters from the Hyper Suprime-Cam Subaru Strategic Program S16A Wide field mass maps

    NASA Astrophysics Data System (ADS)

    Miyazaki, Satoshi; Oguri, Masamune; Hamana, Takashi; Shirasaki, Masato; Koike, Michitaro; Komiyama, Yutaka; Umetsu, Keiichi; Utsumi, Yousuke; Okabe, Nobuhiro; More, Surhud; Medezinski, Elinor; Lin, Yen-Ting; Miyatake, Hironao; Murayama, Hitoshi; Ota, Naomi; Mitsuishi, Ikuyuki

    2018-01-01

    We present the result of searching for clusters of galaxies based on weak gravitational lensing analysis of the ˜160 deg2 area surveyed by Hyper Suprime-Cam (HSC) as a Subaru Strategic Program. HSC is a new prime focus optical imager with a 1.5°-diameter field of view on the 8.2 m Subaru telescope. The superb median seeing on the HSC i-band images of 0.56" allows the reconstruction of high angular resolution mass maps via weak lensing, which is crucial for the weak lensing cluster search. We identify 65 mass map peaks with a signal-to-noise (S/N) ratio larger than 4.7, and carefully examine their properties by cross-matching the clusters with optical and X-ray cluster catalogs. We find that all the 39 peaks with S/N > 5.1 have counterparts in the optical cluster catalogs, and only 2 out of the 65 peaks are probably false positives. The upper limits of X-ray luminosities from the ROSAT All Sky Survey (RASS) imply the existence of an X-ray underluminous cluster population. We show that the X-rays from the shear-selected clusters can be statistically detected by stacking the RASS images. The inferred average X-ray luminosity is about half that of the X-ray-selected clusters of the same mass. The radial profile of the dark matter distribution derived from the stacking analysis is well modeled by the Navarro-Frenk-White profile with a small concentration parameter value of c500 ˜ 2.5, which suggests that the selection bias on the orientation or the internal structure for our shear-selected cluster sample is not strong.

  16. Stellar Stream and Halo Structure in the Andromeda Galaxy from a Subaru/Hyper Suprime-Cam Survey

    NASA Astrophysics Data System (ADS)

    Komiyama, Yutaka; Chiba, Masashi; Tanaka, Mikito; Tanaka, Masayuki; Kirihara, Takanobu; Miki, Yohei; Mori, Masao; Lupton, Robert H.; Guhathakurta, Puragra; Kalirai, Jason S.; Gilbert, Karoline; Kirby, Evan; Lee, Myun Gyoon; Jang, In Sung; Sharma, Sanjib; Hayashi, Kohei

    2018-01-01

    We present wide and deep photometry of the northwestern part of the halo of the Andromeda galaxy (M31) using Hyper Suprime-Cam on the Subaru Telescope. The survey covers a 9.2 deg2 field in the g, i, and NB515 bands and shows a clear red giant branch (RGB) of M31's halo stars and a pronounced red clump (RC) feature. The spatial distribution of RC stars shows a prominent stream feature, the Northwestern (NW) Stream, and a diffuse substructure in the southern part of our survey field. We estimate the distances based on the RC method and obtain (m{--}M) = 24.63 ± 0.191 (random) ± 0.057 (systematic) and 24.29 ± 0.211 (random) ± 0.057 (systematic) mag for the NW Stream and diffuse substructure, respectively, implying that the NW Stream is located behind M31, whereas the diffuse substructure is located in front of it. We also estimate line-of-sight distances along the NW Stream and find that the southern part of the stream is ∼20 kpc closer to us relative to the northern part. The distance to the NW Stream inferred from the isochrone fitting to the color–magnitude diagram favors the RC-based distance, but the tip of the RGB (TRGB)-based distance estimated for NB515-selected RGB stars does not agree with it. The surface number density distribution of RC stars across the NW Stream is found to be approximately Gaussian with an FWHM of ∼25 arcmin (5.7 kpc), with a slight skew to the southwest side. That along the NW Stream shows a complicated structure, including variations in number density and a significant gap in the stream. Based on data collected at the Subaru Telescope, which is operated by the National Astronomical Observatory of Japan.

  17. Individual stellar haloes of massive galaxies measured to 100 kpc at 0.3 < z < 0.5 using Hyper Suprime-Cam

    NASA Astrophysics Data System (ADS)

    Huang, Song; Leauthaud, Alexie; Greene, Jenny E.; Bundy, Kevin; Lin, Yen-Ting; Tanaka, Masayuki; Miyazaki, Satoshi; Komiyama, Yutaka

    2018-04-01

    Massive galaxies display extended light profiles that can reach several hundreds of kiloparsecs. We use data from the Hyper Suprime-Cam (HSC) survey that is simultaneously wide (˜100 deg2) and deep (>28.5 mag arcsec-2 in i band) to study the stellar haloes of a sample of ˜7000 massive galaxies at z ˜ 0.4. The depth of the HSC data enables us to measure surface mass density profiles to 100 kpc for individual galaxies without stacking. As in previous work, we find that more massive galaxies exhibit more extended outer profiles than smaller galaxies. When this extended light is not properly accounted for (because of shallow imaging and/or inadequate profile modelling), the derived stellar mass function can be significantly underestimated at the high-mass end. Across our sample, the ellipticity of outer light profile increases substantially with radius. We show for the first time that these ellipticity gradients steepen dramatically as a function of galaxy mass, but we detect no mass dependence in outer colour gradients. Our results support the two-phase formation scenario for massive galaxies in which outer envelopes are built up at a later time from a series of merging events. We provide surface mass density profiles in a convenient tabulated format to facilitate comparisons with predictions from numerical simulations of galaxy formation.

  18. Cluster galaxy population evolution from the Subaru Hyper Suprime-Cam survey: brightest cluster galaxies, stellar mass distribution, and active galaxies

    NASA Astrophysics Data System (ADS)

    Lin, Yen-Ting; Hsieh, Bau-Ching; Lin, Sheng-Chieh; Oguri, Masamune; Chen, Kai-Feng; Tanaka, Masayuki; Chiu, I.-non; Huang, Song; Kodama, Tadayuki; Leauthaud, Alexie; More, Surhud; Nishizawa, Atsushi J.; Bundy, Kevin; Lin, Lihwai; Miyazaki, Satoshi; HSC Collaboration

    2018-01-01

    The unprecedented depth and area surveyed by the Subaru Strategic Program with the Hyper Suprime-Cam (HSC-SSP) have enabled us to construct and publish the largest distant cluster sample out to z~1 to date. In this exploratory study of cluster galaxy evolution from z=1 to z=0.3, we investigate the stellar mass assembly history of brightest cluster galaxies (BCGs), and evolution of stellar mass and luminosity distributions, stellar mass surface density profile, as well as the population of radio galaxies. Our analysis is the first high redshift application of the top N richest cluster selection, which is shown to allow us to trace the cluster galaxy evolution faithfully. Our stellar mass is derived from a machine-learning algorithm, which we show to be unbiased and accurate with respect to the COSMOS data. We find very mild stellar mass growth in BCGs, and no evidence for evolution in both the total stellar mass-cluster mass correlation and the shape of the stellar mass surface density profile. The clusters are found to contain more red galaxies compared to the expectations from the field, even after the differences in density between the two environments have been taken into account. We also present the first measurement of the radio luminosity distribution in clusters out to z~1.

  19. PhenoCam Dataset v1.0: Vegetation Phenology from Digital Camera Imagery, 2000-2015

    USDA-ARS?s Scientific Manuscript database

    This data set provides a time series of vegetation phenological observations for 133 sites across diverse ecosystems of North America and Europe from 2000-2015. The phenology data were derived from conventional visible-wavelength automated digital camera imagery collected through the PhenoCam Networ...

  20. The nature of H α-selected galaxies along the large-scale structure at z = 0.4 revealed by Subaru Hyper Suprime-Cam survey

    NASA Astrophysics Data System (ADS)

    Koyama, Yusei; Hayashi, Masao; Tanaka, Masayuki; Kodama, Tadayuki; Shimakawa, Rhythm; Yamamoto, Moegi; Nakata, Fumiaki; Tanaka, Ichi; Suzuki, Tomoko L.; Tadaki, Ken-ichi; Nishizawa, Atsushi J.; Yabe, Kiyoto; Toba, Yoshiki; Lin, Lihwai; Jian, Hung-Yu; Komiyama, Yutaka

    2018-01-01

    We present the environmental dependence of color, stellar mass, and star formation (SF) activity in Hα-selected galaxies along the large-scale structure at z = 0.4 hosting twin clusters in the DEEP2-3 field, discovered by the Subaru Strategic Program of Hyper Suprime-Cam (HSC SSP). By combining photo-z-selected galaxies and Hα emitters selected with broadband and narrowband (NB) data from the recent data release of HSC SSP (DR1), we confirm that galaxies in higher-density environments or galaxies in cluster central regions show redder colors. We find that there still remains a possible color-density and color-radius correlation even if we restrict the sample to Hα-selected galaxies, probably due to the presence of massive Hα emitters in denser regions. We also find a hint of increased star formation rates (SFR) amongst Hα emitters toward the highest-density environment, again primarily driven by the excess of red/massive Hα emitters in high-density environments, while their specific SFRs do not significantly change with environment. This work demonstrates the power of the HSC SSP NB data for studying SF galaxies across environments in the distant universe.

  1. Clustering of quasars in a wide luminosity range at redshift 4 with Subaru Hyper Suprime-Cam Wide-field imaging

    NASA Astrophysics Data System (ADS)

    He, Wanqiu; Akiyama, Masayuki; Bosch, James; Enoki, Motohiro; Harikane, Yuichi; Ikeda, Hiroyuki; Kashikawa, Nobunari; Kawaguchi, Toshihiro; Komiyama, Yutaka; Lee, Chien-Hsiu; Matsuoka, Yoshiki; Miyazaki, Satoshi; Nagao, Tohru; Nagashima, Masahiro; Niida, Mana; Nishizawa, Atsushi J.; Oguri, Masamune; Onoue, Masafusa; Oogi, Taira; Ouchi, Masami; Schulze, Andreas; Shirasaki, Yuji; Silverman, John D.; Tanaka, Manobu M.; Tanaka, Masayuki; Toba, Yoshiki; Uchiyama, Hisakazu; Yamashita, Takuji

    2018-01-01

    We examine the clustering of quasars over a wide luminosity range, by utilizing 901 quasars at \\overline{z}_phot˜ 3.8 with -24.73 < M1450 < -22.23 photometrically selected from the Hyper Suprime-Cam Subaru Strategic Program (HSC-SSP) S16A Wide2 date release and 342 more luminous quasars at 3.4 < zspec < 4.6 with -28.0 < M1450 < -23.95 from the Sloan Digital Sky Survey that fall in the HSC survey fields. We measure the bias factors of two quasar samples by evaluating the cross-correlation functions (CCFs) between the quasar samples and 25790 bright z ˜ 4 Lyman break galaxies in M1450 < -21.25 photometrically selected from the HSC dataset. Over an angular scale of 10.0" to 1000.0", the bias factors are 5.93+1.34-1.43 and 2.73+2.44-2.55 for the low- and high-luminosity quasars, respectively, indicating no significant luminosity dependence of quasar clustering at z ˜ 4. It is noted that the bias factor of the luminous quasars estimated by the CCF is smaller than that estimated by the auto-correlation function over a similar redshift range, especially on scales below 40.0". Moreover, the bias factor of the less-luminous quasars implies the minimal mass of their host dark matter halos is 0.3-2 × 1012 h-1 M⊙, corresponding to a quasar duty cycle of 0.001-0.06.

  2. Hyper-luminous dust-obscured galaxies discovered by the Hyper Suprime-Cam on Subaru and WISE

    NASA Astrophysics Data System (ADS)

    Toba, Yoshiki; Nagao, Tohru; Strauss, Michael A.; Aoki, Kentaro; Goto, Tomotsugu; Imanishi, Masatoshi; Kawaguchi, Toshihiro; Terashima, Yuichi; Ueda, Yoshihiro; Bosch, James; Bundy, Kevin; Doi, Yoshiyuki; Inami, Hanae; Komiyama, Yutaka; Lupton, Robert H.; Matsuhara, Hideo; Matsuoka, Yoshiki; Miyazaki, Satoshi; Morokuma, Tomoki; Nakata, Fumiaki; Oi, Nagisa; Onoue, Masafusa; Oyabu, Shinki; Price, Paul; Tait, Philip J.; Takata, Tadafumi; Tanaka, Manobu M.; Terai, Tsuyoshi; Turner, Edwin L.; Uchida, Tomohisa; Usuda, Tomonori; Utsumi, Yousuke; Yamada, Yoshihiko; Wang, Shiang-Yu

    2015-10-01

    We present the photometric properties of a sample of infrared (IR) bright dust-obscured galaxies (DOGs). Combining wide and deep optical images obtained with the Hyper Suprime-Cam on the Subaru Telescope and all-sky mid-IR (MIR) images taken with Wide-Field Infrared Survey Explorer, we discovered 48 DOGs with i - Ks > 1.2 and i - [22] > 7.0, where i, Ks, and [22] represent AB magnitude in the i-band, Ks-band, and 22 μm, respectively, in the GAMA 14 hr field (˜ 9 deg2). Among these objects, 31 (˜ 65%) show power-law spectral energy distributions (SEDs) in the near-IR (NIR) and MIR regime, while the remainder show an NIR bump in their SEDs. Assuming that the redshift distribution for our DOGs sample is Gaussian, with mean and sigma z = 1.99 ± 0.45, we calculated their total IR luminosity using an empirical relation between 22 μm luminosity and total IR luminosity. The average value of the total IR luminosity is (3.5 ± 1.1) × 1013 L⊙, which classifies them as hyper-luminous infrared galaxies. We also derived the total IR luminosity function (LF) and IR luminosity density (LD) for a flux-limited subsample of 18 DOGs with 22 μm flux greater than 3.0 mJy and with i-band magnitude brighter than 24 AB magnitude. The derived space density for this subsample is log φ = -6.59 ± 0.11 [Mpc-3]. The IR LF for DOGs including data obtained from the literature is fitted well by a double-power law. The derived lower limit for the IR LD for our sample is ρIR ˜ 3.8 × 107 [L⊙ Mpc-3] and its contributions to the total IR LD, IR LD of all ultra-luminous infrared galaxies, and that of all DOGs are > 3%, > 9%, and > 15%, respectively.

  3. Probabilistic Selection of High-redshift Quasars with Subaru/Hyper Suprime-Cam Survey

    NASA Astrophysics Data System (ADS)

    Onoue, Masafusa

    High-redshift quasars are an important probe of the distant Universe. They enable observational studies of the early growth of supermassive blackholes, cosmic reionization, chemical enrichment of host galaxies, and so on. Through pioneering optical and near-infrared wide-area surveys such as the SDSS and the VIKING Survey, about one hundred quasars have been found at z > 6 (e.g., Fan et al. (2006b), Venemans et al. (2013)). However, its current small sample size and the fact that most of them are the most luminous (M 1450 <~ -24) population in this epoch prevents one from constraining statistics on high-redshift quasars, namely quasar luminosity function (QLF), and redshift evolution of IGM neutral fraction. Thus, discovery of large number of z > 6 quasars, especially low-luminous or z > 7 quasars, is highly desired for further understanding of the early universe. We are now starting a new ground-breaking survey of high-redshift (z > 6) quasars using the exquisite imaging data provided by the Hyper Suprime-Cam (HSC) Subaru Strategic Program (SSP) Survey. Thanks to its extremely wide coverage and its high sensitivity thorough five optical bands (1,400 deg2 to the depth of r ~ 26 in HSC-Wide layer), it is one of the most powerful contemporary surveys that makes it possible for us to increase the number of z > 6 quasars by almost an order of magnitude, i.e., 300 at z ~ 6 and 50 at z ~ 7, based on the current estimate of the QLF at z > 6 by Willott et al. (2010b). One of the biggest challenges in z > 6 quasar candidate selection is contamination of Galactic brown dwarfs, which have the same point-like appearance as and similarly red colors to the quasars. To overcome this issue and maximize the selection efficiency, we apply a double-layered approach to the HSC survey products, namely combination of two probabilistic selections: SED-fitting and Bayesian selection. In particular, we have developed a template SED fitting method optimized to high-redshift quasars

  4. VizieR Online Data Catalog: MUSYC optical imaging in ECDF-S (Cardamone+, 2010)

    NASA Astrophysics Data System (ADS)

    Cardamone, C. N.; van Dokkum, P. G.; Urry, C. M.; Taniguchi, Y.; Gawiser, E.; Brammer, G.; Taylor, E.; Damen, M.; Treister, E.; Cobb, B. E.; Bond, N.; Schawinski, K.; Lira, P.; Murayama, T.; Saito, T.; Sumikawa, K.

    2011-10-01

    We carried out a medium-band imaging campaign on the Subaru Telescope using the wide field-of-view camera Suprime-Cam. Observations were collected in six runs over 2 years, in 2006 January, February, and December and 2007 January, March, and December. (2 data files).

  5. Lightcurve Studies of Trans-Neptunian Objects from the Outer Solar System Origins Survey using the Hyper Suprime-Camera

    NASA Astrophysics Data System (ADS)

    Alexandersen, Mike; Benecchi, Susan D.; Chen, Ying-Tung; Schwamb, Megan Elizabeth; Wang, Shiang-Yu; Lehner, Matthew; Gladman, Brett; Kavelaars, JJ; Petit, Jean-Marc; Bannister, Michele T.; Gwyn, Stephen; Volk, Kathryn

    2016-10-01

    Lightcurves can reveal information about the gravitational processes that have acted on small bodies since their formation and/or their gravitational history.At the extremes, lightcurves can provide constraints on the material properties and interior structure of individual objects.In large sets, lightcurves can possibly shed light on the source of small body populations that did not form in place (such as the dynamically excited trans-Neptunian Objects (TNOs)).We have used the sparsely sampled photometry from the well characterized Outer Solar System Origins Survey (OSSOS) discovery and recovery observations to identify TNOs with potentially large amplitude lightcurves.Large lightcurve amplitudes would indicate that the objects are likely elongated or in potentially interesting spin states; however, this would need to be confirmed with further follow-up observations.We here present the results of a 6-hour pilot study of a subset of 17 OSSOS objects using Hyper Suprime-Cam (HSC) on the Subaru Telescope.Subaru's large aperture and HSC's large field of view allows us to obtain measurements on multiple objects with a range of magnitudes in each telescope pointing.Photometry was carefully measusured using an elongated aperture method to account for the motion of the objects, producing the short but precise lightcurves that we present here.The OSSOS objects span a large range of sizes, from as large as several hundred kilometres to as small as a few tens of kilometres in diameter.We are thus investigating smaller objects than previous light-curve projects have typically studied.

  6. Touch And Go Camera System (TAGCAMS) for the OSIRIS-REx Asteroid Sample Return Mission

    NASA Astrophysics Data System (ADS)

    Bos, B. J.; Ravine, M. A.; Caplinger, M.; Schaffner, J. A.; Ladewig, J. V.; Olds, R. D.; Norman, C. D.; Huish, D.; Hughes, M.; Anderson, S. K.; Lorenz, D. A.; May, A.; Jackman, C. D.; Nelson, D.; Moreau, M.; Kubitschek, D.; Getzandanner, K.; Gordon, K. E.; Eberhardt, A.; Lauretta, D. S.

    2018-02-01

    NASA's OSIRIS-REx asteroid sample return mission spacecraft includes the Touch And Go Camera System (TAGCAMS) three camera-head instrument. The purpose of TAGCAMS is to provide imagery during the mission to facilitate navigation to the target asteroid, confirm acquisition of the asteroid sample, and document asteroid sample stowage. The cameras were designed and constructed by Malin Space Science Systems (MSSS) based on requirements developed by Lockheed Martin and NASA. All three of the cameras are mounted to the spacecraft nadir deck and provide images in the visible part of the spectrum, 400-700 nm. Two of the TAGCAMS cameras, NavCam 1 and NavCam 2, serve as fully redundant navigation cameras to support optical navigation and natural feature tracking. Their boresights are aligned in the nadir direction with small angular offsets for operational convenience. The third TAGCAMS camera, StowCam, provides imagery to assist with and confirm proper stowage of the asteroid sample. Its boresight is pointed at the OSIRIS-REx sample return capsule located on the spacecraft deck. All three cameras have at their heart a 2592 × 1944 pixel complementary metal oxide semiconductor (CMOS) detector array that provides up to 12-bit pixel depth. All cameras also share the same lens design and a camera field of view of roughly 44° × 32° with a pixel scale of 0.28 mrad/pixel. The StowCam lens is focused to image features on the spacecraft deck, while both NavCam lens focus positions are optimized for imaging at infinity. A brief description of the TAGCAMS instrument and how it is used to support critical OSIRIS-REx operations is provided.

  7. Coincidence velocity map imaging using Tpx3Cam, a time stamping optical camera with 1.5 ns timing resolution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhao, Arthur; van Beuzekom, Martin; Bouwens, Bram

    Here, we demonstrate a coincidence velocity map imaging apparatus equipped with a novel time-stamping fast optical camera, Tpx3Cam, whose high sensitivity and nanosecond timing resolution allow for simultaneous position and time-of-flight detection. This single detector design is simple, flexible, and capable of highly differential measurements. We show detailed characterization of the camera and its application in strong field ionization experiments.

  8. Coincidence velocity map imaging using Tpx3Cam, a time stamping optical camera with 1.5 ns timing resolution

    DOE PAGES

    Zhao, Arthur; van Beuzekom, Martin; Bouwens, Bram; ...

    2017-11-07

    Here, we demonstrate a coincidence velocity map imaging apparatus equipped with a novel time-stamping fast optical camera, Tpx3Cam, whose high sensitivity and nanosecond timing resolution allow for simultaneous position and time-of-flight detection. This single detector design is simple, flexible, and capable of highly differential measurements. We show detailed characterization of the camera and its application in strong field ionization experiments.

  9. Multiwavelength study of X-ray luminous clusters in the Hyper Suprime-Cam Subaru Strategic Program S16A field

    NASA Astrophysics Data System (ADS)

    Miyaoka, Keita; Okabe, Nobuhiro; Kitaguchi, Takao; Oguri, Masamune; Fukazawa, Yasushi; Mandelbaum, Rachel; Medezinski, Elinor; Babazaki, Yasunori; Nishizawa, Atsushi J.; Hamana, Takashi; Lin, Yen-Ting; Akamatsu, Hiroki; Chiu, I.-Non; Fujita, Yutaka; Ichinohe, Yuto; Komiyama, Yutaka; Sasaki, Toru; Takizawa, Motokazu; Ueda, Shutaro; Umetsu, Keiichi; Coupon, Jean; Hikage, Chiaki; Hoshino, Akio; Leauthaud, Alexie; Matsushita, Kyoko; Mitsuishi, Ikuyuki; Miyatake, Hironao; Miyazaki, Satoshi; More, Surhud; Nakazawa, Kazuhiro; Ota, Naomi; Sato, Kousuke; Spergel, David; Tamura, Takayuki; Tanaka, Masayuki; Tanaka, Manobu M.; Utsumi, Yousuke

    2018-01-01

    We present a joint X-ray, optical, and weak-lensing analysis for X-ray luminous galaxy clusters selected from the MCXC (Meta-Catalog of X-Ray Detected Clusters of Galaxies) cluster catalog in the Hyper Suprime-Cam Subaru Strategic Program (HSC-SSP) survey field with S16A data. As a pilot study for a series of papers, we measure hydrostatic equilibrium (HE) masses using XMM-Newton data for four clusters in the current coverage area out of a sample of 22 MCXC clusters. We additionally analyze a non-MCXC cluster associated with one MCXC cluster. We show that HE masses for the MCXC clusters are correlated with cluster richness from the CAMIRA catalog, while that for the non-MCXC cluster deviates from the scaling relation. The mass normalization of the relationship between cluster richness and HE mass is compatible with one inferred by matching CAMIRA cluster abundance with a theoretical halo mass function. The mean gas mass fraction based on HE masses for the MCXC clusters is = 0.125 ± 0.012 at spherical overdensity Δ = 500, which is ˜80%-90% of the cosmic mean baryon fraction, Ωb/Ωm, measured by cosmic microwave background experiments. We find that the mean baryon fraction estimated from X-ray and HSC-SSP optical data is comparable to Ωb/Ωm. A weak-lensing shear catalog of background galaxies, combined with photometric redshifts, is currently available only for three clusters in our sample. Hydrostatic equilibrium masses roughly agree with weak-lensing masses, albeit with large uncertainty. This study demonstrates that further multiwavelength study for a large sample of clusters using X-ray, HSC-SSP optical, and weak-lensing data will enable us to understand cluster physics and utilize cluster-based cosmology.

  10. Illustrating MastCam Capabilities with a Terrestrial Scene

    NASA Image and Video Library

    2011-11-28

    This set of views illustrates capabilities of the Mast Camera MastCam instrument on NASA Mars Science Laboratory Curiosity rover, using a scene on Earth as an example of what MastCam two cameras can see from different distances.

  11. SenseCam: A new tool for memory rehabilitation?

    PubMed

    Dubourg, L; Silva, A R; Fitamen, C; Moulin, C J A; Souchay, C

    2016-12-01

    The emergence of life-logging technologies has led neuropsychologist to focus on understanding how this new technology could help patients with memory disorders. Despite the growing number of studies using life-logging technologies, a theoretical framework supporting its effectiveness is lacking. This review focuses on the use of life-logging in the context of memory rehabilitation, particularly the use of SenseCam, a wearable camera allowing passive image capture. In our opinion, reviewing SenseCam images can be effective for memory rehabilitation only if it provides more than an assessment of prior occurrence in ways that reinstates previous thoughts, feelings and sensory information, thus stimulating recollection. Considering the fact that, in memory impairment, self-initiated processes are impaired, we propose that the environmental support hypothesis can explain the value of SenseCam for memory retrieval. Twenty-five research studies were selected for this review and despite the general acceptance of the value of SenseCam as a memory technique, only a small number of studies focused on recollection. We discuss the usability of this tool to improve episodic memory and in particular, recollection. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  12. Checking out ChemCam View

    NASA Image and Video Library

    2012-08-17

    This mosaic shows the calibration target for the Chemistry and Camera ChemCam instrument on NASA Curiosity rover, as seen by the ChemCam remote micro-imager. The 10 images incorporated in this mosaic were taken on Aug. 15.

  13. New Focal Plane Array Controller for the Instruments of the Subaru Telescope

    NASA Astrophysics Data System (ADS)

    Nakaya, Hidehiko; Komiyama, Yutaka; Miyazaki, Satoshi; Yamashita, Takuya; Yagi, Masafumi; Sekiguchi, Maki

    2006-03-01

    We have developed a next-generation data acquisition system, MESSIA5 (Modularized Extensible System for Image Acquisition), which comprises the digital part of a focal plane array controller. The new data acquisition system was constructed based on a 64 bit, 66 MHz PCI (peripheral component interconnect) bus architecture and runs on an x86 CPU computer with (non-real-time) Linux. The system, including the CPU board, is placed at the telescope focus, and standard gigabit Ethernet is adopted for the data transfer, as opposed to a dedicated fiber link. During the summer of 2002, we installed the new system for the first time on the Subaru prime-focus camera Suprime-Cam and successfully improved the observing performance.

  14. SpectraCAM SPM: a camera system with high dynamic range for scientific and medical applications

    NASA Astrophysics Data System (ADS)

    Bhaskaran, S.; Baiko, D.; Lungu, G.; Pilon, M.; VanGorden, S.

    2005-08-01

    A scientific camera system having high dynamic range designed and manufactured by Thermo Electron for scientific and medical applications is presented. The newly developed CID820 image sensor with preamplifier-per-pixel technology is employed in this camera system. The 4 Mega-pixel imaging sensor has a raw dynamic range of 82dB. Each high-transparent pixel is based on a preamplifier-per-pixel architecture and contains two photogates for non-destructive readout of the photon-generated charge (NDRO). Readout is achieved via parallel row processing with on-chip correlated double sampling (CDS). The imager is capable of true random pixel access with a maximum operating speed of 4MHz. The camera controller consists of a custom camera signal processor (CSP) with an integrated 16-bit A/D converter and a PowerPC-based CPU running a Linux embedded operating system. The imager is cooled to -40C via three-stage cooler to minimize dark current. The camera housing is sealed and is designed to maintain the CID820 imager in the evacuated chamber for at least 5 years. Thermo Electron has also developed custom software and firmware to drive the SpectraCAM SPM camera. Included in this firmware package is the new Extreme DRTM algorithm that is designed to extend the effective dynamic range of the camera by several orders of magnitude up to 32-bit dynamic range. The RACID Exposure graphical user interface image analysis software runs on a standard PC that is connected to the camera via Gigabit Ethernet.

  15. Camera-augmented mobile C-arm (CamC): A feasibility study of augmented reality imaging in the operating room.

    PubMed

    von der Heide, Anna Maria; Fallavollita, Pascal; Wang, Lejing; Sandner, Philipp; Navab, Nassir; Weidert, Simon; Euler, Ekkehard

    2018-04-01

    In orthopaedic trauma surgery, image-guided procedures are mostly based on fluoroscopy. The reduction of radiation exposure is an important goal. The purpose of this work was to investigate the impact of a camera-augmented mobile C-arm (CamC) on radiation exposure and the surgical workflow during a first clinical trial. Applying a workflow-oriented approach, 10 general workflow steps were defined to compare the CamC to traditional C-arms. The surgeries included were arbitrarily identified and assigned to the study. The evaluation criteria were radiation exposure and operation time for each workflow step and the entire surgery. The evaluation protocol was designed and conducted in a single-centre study. The radiation exposure was remarkably reduced by 18 X-ray shots 46% using the CamC while keeping similar surgery times. The intuitiveness of the system, its easy integration into the surgical workflow, and its great potential to reduce radiation have been demonstrated. Copyright © 2017 John Wiley & Sons, Ltd.

  16. Structure and Population of the Andromeda Stellar Halo from a Subaru/Suprime-Cam Survey

    NASA Astrophysics Data System (ADS)

    Tanaka, Mikito; Chiba, Masashi; Komiyama, Yutaka; Guhathakurta, Puragra; Kalirai, Jason S.; Iye, Masanori

    2010-01-01

    We present a photometric survey of the stellar halo of the nearest giant spiral galaxy, Andromeda (M31), using Suprime-Cam on the Subaru Telescope. A detailed analysis of VI color-magnitude diagrams of the resolved stellar population is used to measure properties such as line-of-sight distance, surface brightness, metallicity, and age. These are used to isolate and characterize different components of the M31 halo: (1) the giant southern stream (GSS); (2) several other substructures; and (3) the smooth halo. First, the GSS is characterized by a broad red giant branch (RGB) and a metal-rich/intermediate-age red clump (RC). The I magnitude of the well-defined tip of the RGB suggests that the distance to the observed GSS field is (m - M)0 = 24.73 ± 0.11 (883 ± 45 kpc) at a projected radius of R ~ 30 kpc from M31's center. The GSS shows a high metallicity peaked at [Fe/H]gsim-0.5 with a mean (median) of -0.7 (-0.6), estimated via comparison with theoretical isochrones. Combined with the luminosity of the RC, we estimate the mean age of its stellar population to be ~8 Gyr. The mass of its progenitor galaxy is likely in the range of 107-109 M sun. Second, we study M31's halo substructure along the northwest/southeast minor axis out to R ~ 100 kpc and the southwest major-axis region at R ~ 60 kpc. We confirm two substructures in the southeast halo reported by Ibata et al. and discover two overdense substructures in the northwest halo. We investigate the properties of these four substructures as well as other structures including the western shelf and find that differences in stellar populations among these systems, thereby suggesting each has a different origin. Our statistical analysis implies that the M31 halo as a whole may contain at least 16 substructures, each with a different origin, so its outer halo has experienced at least this many accretion events involving dwarf satellites with mass 107-109 M sun since a redshift of z ~ 1. Third, we investigate the

  17. First Results on the Cluster Galaxy Population from the Subaru Hyper Suprime-Cam Survey. III. Brightest Cluster Galaxies, Stellar Mass Distribution, and Active Galaxies

    NASA Astrophysics Data System (ADS)

    Lin, Yen-Ting; Hsieh, Bau-Ching; Lin, Sheng-Chieh; Oguri, Masamune; Chen, Kai-Feng; Tanaka, Masayuki; Chiu, I.-Non; Huang, Song; Kodama, Tadayuki; Leauthaud, Alexie; More, Surhud; Nishizawa, Atsushi J.; Bundy, Kevin; Lin, Lihwai; Miyazaki, Satoshi

    2017-12-01

    The unprecedented depth and area surveyed by the Subaru Strategic Program with the Hyper Suprime-Cam (HSC-SSP) have enabled us to construct and publish the largest distant cluster sample out to z∼ 1 to date. In this exploratory study of cluster galaxy evolution from z = 1 to z = 0.3, we investigate the stellar mass assembly history of brightest cluster galaxies (BCGs), the evolution of stellar mass and luminosity distributions, the stellar mass surface density profile, as well as the population of radio galaxies. Our analysis is the first high-redshift application of the top N richest cluster selection, which is shown to allow us to trace the cluster galaxy evolution faithfully. Over the 230 deg2 area of the current HSC-SSP footprint, selecting the top 100 clusters in each of the four redshift bins allows us to observe the buildup of galaxy population in descendants of clusters whose z≈ 1 mass is about 2× {10}14 {M}ȯ . Our stellar mass is derived from a machine-learning algorithm, which is found to be unbiased and accurate with respect to the COSMOS data. We find very mild stellar mass growth in BCGs (about 35% between z = 1 and 0.3), and no evidence for evolution in both the total stellar mass–cluster mass correlation and the shape of the stellar mass surface density profile. We also present the first measurement of the radio luminosity distribution in clusters out to z∼ 1, and show hints of changes in the dominant accretion mode powering the cluster radio galaxies at z∼ 0.8.

  18. The role of complementary and alternative medicine (CAM) in Germany - a focus group study of GPs.

    PubMed

    Joos, Stefanie; Musselmann, Berthold; Miksch, Antje; Rosemann, Thomas; Szecsenyi, Joachim

    2008-06-12

    There has been a marked increase in the use of complementary and alternative medicine (CAM) in recent years worldwide. In Germany, apart from 'Heilpraktiker' (= state-licensed, non-medical CAM practitioners), some general practitioners (GPs) provide CAM in their practices. This paper aims to explore the attitudes of GPs about the role of CAM in Germany, in relation to the healthcare system, quality of care, medical education and research. Furthermore, experiences of GPs integrating CAM in their daily practice were explored. Using a qualitative methodological approach 3 focus groups with a convenience sample of 17 GPs were conducted. The discussions were transcribed verbatim and analysed using qualitative content analysis. The majority of the participating GPs had integrated one or more CAM therapies into their every-day practice. Four key themes were identified based on the topics covered in the focus groups: the role of CAM within the German healthcare system, quality of care, education and research. Within the theme 'role of CAM within the healthcare system' there were five categories: integration of CAM, CAM in the Statutory Health Insurance, modernisation of the Statutory Health Insurance Act, individual healthcare services and 'Heilpraktiker'. Regarding quality of care there were two broad groups of GPs: those who thought patients would benefit from standardizing CAM and those who feared that quality control would interfere with the individual approach of CAM. The main issues identified relating to research and education were the need for the development of alternative research strategies and the low quality of existing CAM education respectively. The majority of the participating GPs considered CAM as a reasonable complementary approach within primary care. The study increased our understanding of GPs attitudes about the role of CAM within the German healthcare system and the use of 'Heilpraktiker' as a competing CAM-provider. It seems to be a need for

  19. Curiosity ChemCam Removes Dust

    NASA Image and Video Library

    2013-04-08

    This pair of images taken a few minutes apart show how laser firing by NASA Mars rover Curiosity removes dust from the surface of a rock. The images were taken by the remote micro-imager camera in the laser-firing Chemistry and Camera ChemCam.

  20. Passive auto-focus for digital still cameras and camera phones: Filter-switching and low-light techniques

    NASA Astrophysics Data System (ADS)

    Gamadia, Mark Noel

    In order to gain valuable market share in the growing consumer digital still camera and camera phone market, camera manufacturers have to continually add and improve existing features to their latest product offerings. Auto-focus (AF) is one such feature, whose aim is to enable consumers to quickly take sharply focused pictures with little or no manual intervention in adjusting the camera's focus lens. While AF has been a standard feature in digital still and cell-phone cameras, consumers often complain about their cameras' slow AF performance, which may lead to missed photographic opportunities, rendering valuable moments and events with undesired out-of-focus pictures. This dissertation addresses this critical issue to advance the state-of-the-art in the digital band-pass filter, passive AF method. This method is widely used to realize AF in the camera industry, where a focus actuator is adjusted via a search algorithm to locate the in-focus position by maximizing a sharpness measure extracted from a particular frequency band of the incoming image of the scene. There are no known systematic methods for automatically deriving the parameters such as the digital pass-bands or the search step-size increments used in existing passive AF schemes. Conventional methods require time consuming experimentation and tuning in order to arrive at a set of parameters which balance AF performance in terms of speed and accuracy ultimately causing a delay in product time-to-market. This dissertation presents a new framework for determining an optimal set of passive AF parameters, named Filter- Switching AF, providing an automatic approach to achieve superior AF performance, both in good and low lighting conditions based on the following performance measures (metrics): speed (total number of iterations), accuracy (offset from truth), power consumption (total distance moved), and user experience (in-focus position overrun). Performance results using three different prototype cameras

  1. Searches for new Milky Way satellites from the first two years of data of the Subaru/Hyper Suprime-Cam survey: Discovery of Cetus III

    NASA Astrophysics Data System (ADS)

    Homma, Daisuke; Chiba, Masashi; Okamoto, Sakurako; Komiyama, Yutaka; Tanaka, Masayuki; Tanaka, Mikito; Ishigaki, Miho N.; Hayashi, Kohei; Arimoto, Nobuo; Garmilla, José A.; Lupton, Robert H.; Strauss, Michael A.; Miyazaki, Satoshi; Wang, Shiang-Yu; Murayama, Hitoshi

    2018-01-01

    We present the results from a search for new Milky Way (MW) satellites from the first two years of data from the Hyper Suprime-Cam (HSC) Subaru Strategic Program (SSP) ˜300 deg2 and report the discovery of a highly compelling ultra-faint dwarf galaxy candidate in Cetus. This is the second ultra-faint dwarf we have discovered after Virgo I reported in our previous paper. This satellite, Cetus III, has been identified as a statistically significant (10.7 σ) spatial overdensity of star-like objects, which are selected from a relevant isochrone filter designed for a metal-poor and old stellar population. This stellar system is located at a heliocentric distance of 251^{+24}_{-11}kpc with a most likely absolute magnitude of MV = -2.4 ± 0.6 mag estimated from a Monte Carlo analysis. Cetus III is extended with a half-light radius of r_h = 90^{+42}_{-17}pc, suggesting that this is a faint dwarf satellite in the MW located beyond the detection limit of the Sloan Digital Sky Survey. Further spectroscopic studies are needed to assess the nature of this stellar system. We also revisit and update the parameters for Virgo I, finding M_V = -0.33^{+0.75}_{-0.87}mag and r_h = 47^{+19}_{-13}pc. Using simulations of Λ-dominated cold dark matter models, we predict that we should find one or two new MW satellites from ˜300 deg2 HSC-SSP data, in rough agreement with the discovery rate so far. The further survey and completion of HSC-SSP over ˜1400 deg2 will provide robust insights into the missing satellites problem.

  2. SILVERRUSH. VI. A simulation of Lyα emitters in the reionization epoch and a comparison with Subaru Hyper Suprime-Cam survey early data

    NASA Astrophysics Data System (ADS)

    Inoue, Akio K.; Hasegawa, Kenji; Ishiyama, Tomoaki; Yajima, Hidenobu; Shimizu, Ikkoh; Umemura, Masayuki; Konno, Akira; Harikane, Yuichi; Shibuya, Takatoshi; Ouchi, Masami; Shimasaku, Kazuhiro; Ono, Yoshiaki; Kusakabe, Haruka; Higuchi, Ryo; Lee, Chien-Hsiu

    2018-06-01

    The survey of Lyman α emitters (LAEs) with the Subaru Hyper Suprime-Cam, called SILVERRUSH (Ouchi et al. 2018, PASJ, 70, S13), is producing massive data of LAEs at z ≳ 6. Here we present LAE simulations to compare the SILVERRUSH data. In 1623 comoving Mpc3 boxes, where numerical radiative transfer calculations of reionization were performed, LAEs have been modeled with physically motivated analytic recipes as a function of halo mass. We have examined 23 models depending on the presence or absence of dispersion of halo Lyα emissivity, dispersion of the halo Lyα optical depth, τα, and halo mass dependence of τα. The unique free parameter in our model, a pivot value of τα, is calibrated so as to reproduce the z = 5.7 Lyα luminosity function (LF) of SILVERRUSH. We compare our model predictions with Lyα LFs at z = 6.6 and 7.3, LAE angular auto-correlation functions (ACFs) at z = 5.7 and 6.6, and LAE fractions in Lyman break galaxies at 5 < z < 7. The Lyα LFs and ACFs are reproduced by multiple models, but the LAE fraction turns out to be the most critical test. The dispersion of τα and the halo mass dependence of τα are essential to explain all observations reasonably. Therefore, a simple model of one-to-one correspondence between halo mass and Lyα luminosity with a constant Lyα escape fraction has been ruled out. Based on our best model, we present a formula to estimate the intergalactic neutral hydrogen fraction, x_{H I}, from the observed Lyα luminosity density at z ≳ 6. We finally obtain x_{H I}=0.5_{-0.3}^{+0.1} as a volume-average at z = 7.3.

  3. SILVERRUSH. VI. A simulation of Lyα emitters in the reionization epoch and a comparison with Subaru Hyper Suprime-Cam survey early data

    NASA Astrophysics Data System (ADS)

    Inoue, Akio K.; Hasegawa, Kenji; Ishiyama, Tomoaki; Yajima, Hidenobu; Shimizu, Ikkoh; Umemura, Masayuki; Konno, Akira; Harikane, Yuichi; Shibuya, Takatoshi; Ouchi, Masami; Shimasaku, Kazuhiro; Ono, Yoshiaki; Kusakabe, Haruka; Higuchi, Ryo; Lee, Chien-Hsiu

    2018-05-01

    The survey of Lyman α emitters (LAEs) with the Subaru Hyper Suprime-Cam, called SILVERRUSH (Ouchi et al. 2018, PASJ, 70, S13), is producing massive data of LAEs at z ≳ 6. Here we present LAE simulations to compare the SILVERRUSH data. In 1623 comoving Mpc3 boxes, where numerical radiative transfer calculations of reionization were performed, LAEs have been modeled with physically motivated analytic recipes as a function of halo mass. We have examined 23 models depending on the presence or absence of dispersion of halo Lyα emissivity, dispersion of the halo Lyα optical depth, τα, and halo mass dependence of τα. The unique free parameter in our model, a pivot value of τα, is calibrated so as to reproduce the z = 5.7 Lyα luminosity function (LF) of SILVERRUSH. We compare our model predictions with Lyα LFs at z = 6.6 and 7.3, LAE angular auto-correlation functions (ACFs) at z = 5.7 and 6.6, and LAE fractions in Lyman break galaxies at 5 < z < 7. The Lyα LFs and ACFs are reproduced by multiple models, but the LAE fraction turns out to be the most critical test. The dispersion of τα and the halo mass dependence of τα are essential to explain all observations reasonably. Therefore, a simple model of one-to-one correspondence between halo mass and Lyα luminosity with a constant Lyα escape fraction has been ruled out. Based on our best model, we present a formula to estimate the intergalactic neutral hydrogen fraction, x_{H I}, from the observed Lyα luminosity density at z ≳ 6. We finally obtain x_{H I}=0.5_{-0.3}^{+0.1} as a volume-average at z = 7.3.

  4. Readying ChemCam

    NASA Image and Video Library

    2012-08-17

    This image shows the calibration target for the Chemistry and Camera ChemCam instrument on NASA Curiosity rover. The calibration target is one square and a group of nine circles that look dark in the black-and-white image.

  5. The PanCam Instrument for the ExoMars Rover

    NASA Astrophysics Data System (ADS)

    Coates, A. J.; Jaumann, R.; Griffiths, A. D.; Leff, C. E.; Schmitz, N.; Josset, J.-L.; Paar, G.; Gunn, M.; Hauber, E.; Cousins, C. R.; Cross, R. E.; Grindrod, P.; Bridges, J. C.; Balme, M.; Gupta, S.; Crawford, I. A.; Irwin, P.; Stabbins, R.; Tirsch, D.; Vago, J. L.; Theodorou, T.; Caballo-Perucha, M.; Osinski, G. R.; PanCam Team

    2017-07-01

    The scientific objectives of the ExoMars rover are designed to answer several key questions in the search for life on Mars. In particular, the unique subsurface drill will address some of these, such as the possible existence and stability of subsurface organics. PanCam will establish the surface geological and morphological context for the mission, working in collaboration with other context instruments. Here, we describe the PanCam scientific objectives in geology, atmospheric science, and 3-D vision. We discuss the design of PanCam, which includes a stereo pair of Wide Angle Cameras (WACs), each of which has an 11-position filter wheel and a High Resolution Camera (HRC) for high-resolution investigations of rock texture at a distance. The cameras and electronics are housed in an optical bench that provides the mechanical interface to the rover mast and a planetary protection barrier. The electronic interface is via the PanCam Interface Unit (PIU), and power conditioning is via a DC-DC converter. PanCam also includes a calibration target mounted on the rover deck for radiometric calibration, fiducial markers for geometric calibration, and a rover inspection mirror.

  6. Calibration and accuracy analysis of a focused plenoptic camera

    NASA Astrophysics Data System (ADS)

    Zeller, N.; Quint, F.; Stilla, U.

    2014-08-01

    In this article we introduce new methods for the calibration of depth images from focused plenoptic cameras and validate the results. We start with a brief description of the concept of a focused plenoptic camera and how from the recorded raw image a depth map can be estimated. For this camera, an analytical expression of the depth accuracy is derived for the first time. In the main part of the paper, methods to calibrate a focused plenoptic camera are developed and evaluated. The optical imaging process is calibrated by using a method which is already known from the calibration of traditional cameras. For the calibration of the depth map two new model based methods, which make use of the projection concept of the camera are developed. These new methods are compared to a common curve fitting approach, which is based on Taylor-series-approximation. Both model based methods show significant advantages compared to the curve fitting method. They need less reference points for calibration than the curve fitting method and moreover, supply a function which is valid in excess of the range of calibration. In addition the depth map accuracy of the plenoptic camera was experimentally investigated for different focal lengths of the main lens and is compared to the analytical evaluation.

  7. Depth estimation and camera calibration of a focused plenoptic camera for visual odometry

    NASA Astrophysics Data System (ADS)

    Zeller, Niclas; Quint, Franz; Stilla, Uwe

    2016-08-01

    This paper presents new and improved methods of depth estimation and camera calibration for visual odometry with a focused plenoptic camera. For depth estimation we adapt an algorithm previously used in structure-from-motion approaches to work with images of a focused plenoptic camera. In the raw image of a plenoptic camera, scene patches are recorded in several micro-images under slightly different angles. This leads to a multi-view stereo-problem. To reduce the complexity, we divide this into multiple binocular stereo problems. For each pixel with sufficient gradient we estimate a virtual (uncalibrated) depth based on local intensity error minimization. The estimated depth is characterized by the variance of the estimate and is subsequently updated with the estimates from other micro-images. Updating is performed in a Kalman-like fashion. The result of depth estimation in a single image of the plenoptic camera is a probabilistic depth map, where each depth pixel consists of an estimated virtual depth and a corresponding variance. Since the resulting image of the plenoptic camera contains two plains: the optical image and the depth map, camera calibration is divided into two separate sub-problems. The optical path is calibrated based on a traditional calibration method. For calibrating the depth map we introduce two novel model based methods, which define the relation of the virtual depth, which has been estimated based on the light-field image, and the metric object distance. These two methods are compared to a well known curve fitting approach. Both model based methods show significant advantages compared to the curve fitting method. For visual odometry we fuse the probabilistic depth map gained from one shot of the plenoptic camera with the depth data gained by finding stereo correspondences between subsequent synthesized intensity images of the plenoptic camera. These images can be synthesized totally focused and thus finding stereo correspondences is enhanced

  8. The PanCam instrument on the 2018 Exomars rover: Scientific objectives

    NASA Astrophysics Data System (ADS)

    Jaumann, Ralf; Coates, Andrew; Hauber, Ernst; Hoffmann, Harald; Schmitz, Nicole; Le Deit, Laetitia; Tirsch, Daniela; Paar, Gerhard; Griffiths, Andrew

    2010-05-01

    The Exomars Panoramic Camera System is an imaging suite of three camera heads to be mounted on the ExoMars rover`s mast, with the boresight 1.8 m above ground. As late as the ExoMars Pasteur Payload Design Review (PDR) in 2009, the PanCam consists of two identical wide angle cameras (WAC) with fixed focal length lenses, and a high resolution camera (HRC) with an automatic focus mechanism, placed adjacent to the right WAC. The WAC stereo pair provides binocular vision for stereoscopic studies as well as 12 filter positions (per camera) for stereoscopic colour imaging and scientific multispectral studies. The stereo baseline of the pair is 500 mm. The two WAC have 22 mm focal length, f/10 lenses that illuminate detectors with 1024 × 1024 pixels. WAC lenses are fixed, with an optimal focus set to 4 m, and a focus ranging from 1.2 m (corresponding to the nearest view of the calibration target on the rover deck) to infinity. The HRC is able to focus between 0.9 m (distance to a drill core on the rover`s sample tray) and infinity. The instantaneous field of views of WAC and HRC are 580 μrad/pixel and 83 μrad/pixel, respectively. The corresponding resolution (in mm/pixel) at a distance of 2 m are 1.2 (WAC) and 0.17 (HRC), at 100 m distance it is 58 (WAC) and 8.3 (HRC). WAC and HRC will be geometrically co-aligned. The main scientific goal of PanCam is the geologic characterisation of the environment in which the rover is operating, providing the context for investigations carried out by the other instruments of the Pasteur payload. PanCam data will serve as a bridge between orbital data (high-resolution images from HRSC, CTX, and HiRISE, and spectrometer data from OMEGA and CRISM) and the data acquired in situ on the Martian surface. The position of HRC on top of the rover`s mast enables the detailed panoramic inspection of surface features over the full horizontal range of 360° even at large distances, an important prerequisite to identify the scientifically most

  9. The PanCam Instrument for the ExoMars Rover

    PubMed Central

    Coates, A.J.; Jaumann, R.; Griffiths, A.D.; Leff, C.E.; Schmitz, N.; Josset, J.-L.; Paar, G.; Gunn, M.; Hauber, E.; Cousins, C.R.; Cross, R.E.; Grindrod, P.; Bridges, J.C.; Balme, M.; Gupta, S.; Crawford, I.A.; Irwin, P.; Stabbins, R.; Tirsch, D.; Vago, J.L.; Theodorou, T.; Caballo-Perucha, M.; Osinski, G.R.

    2017-01-01

    Abstract The scientific objectives of the ExoMars rover are designed to answer several key questions in the search for life on Mars. In particular, the unique subsurface drill will address some of these, such as the possible existence and stability of subsurface organics. PanCam will establish the surface geological and morphological context for the mission, working in collaboration with other context instruments. Here, we describe the PanCam scientific objectives in geology, atmospheric science, and 3-D vision. We discuss the design of PanCam, which includes a stereo pair of Wide Angle Cameras (WACs), each of which has an 11-position filter wheel and a High Resolution Camera (HRC) for high-resolution investigations of rock texture at a distance. The cameras and electronics are housed in an optical bench that provides the mechanical interface to the rover mast and a planetary protection barrier. The electronic interface is via the PanCam Interface Unit (PIU), and power conditioning is via a DC-DC converter. PanCam also includes a calibration target mounted on the rover deck for radiometric calibration, fiducial markers for geometric calibration, and a rover inspection mirror. Key Words: Mars—ExoMars—Instrumentation—Geology—Atmosphere—Exobiology—Context. Astrobiology 17, 511–541.

  10. OCAMS: The OSIRIS-REx Camera Suite

    NASA Astrophysics Data System (ADS)

    Rizk, B.; Drouet d'Aubigny, C.; Golish, D.; Fellows, C.; Merrill, C.; Smith, P.; Walker, M. S.; Hendershot, J. E.; Hancock, J.; Bailey, S. H.; DellaGiustina, D. N.; Lauretta, D. S.; Tanner, R.; Williams, M.; Harshman, K.; Fitzgibbon, M.; Verts, W.; Chen, J.; Connors, T.; Hamara, D.; Dowd, A.; Lowman, A.; Dubin, M.; Burt, R.; Whiteley, M.; Watson, M.; McMahon, T.; Ward, M.; Booher, D.; Read, M.; Williams, B.; Hunten, M.; Little, E.; Saltzman, T.; Alfred, D.; O'Dougherty, S.; Walthall, M.; Kenagy, K.; Peterson, S.; Crowther, B.; Perry, M. L.; See, C.; Selznick, S.; Sauve, C.; Beiser, M.; Black, W.; Pfisterer, R. N.; Lancaster, A.; Oliver, S.; Oquest, C.; Crowley, D.; Morgan, C.; Castle, C.; Dominguez, R.; Sullivan, M.

    2018-02-01

    The OSIRIS-REx Camera Suite (OCAMS) will acquire images essential to collecting a sample from the surface of Bennu. During proximity operations, these images will document the presence of satellites and plumes, record spin state, enable an accurate model of the asteroid's shape, and identify any surface hazards. They will confirm the presence of sampleable regolith on the surface, observe the sampling event itself, and image the sample head in order to verify its readiness to be stowed. They will document Bennu's history as an example of early solar system material, as a microgravity body with a planetesimal size-scale, and as a carbonaceous object. OCAMS is fitted with three cameras. The MapCam will record color images of Bennu as a point source on approach to the asteroid in order to connect Bennu's ground-based point-source observational record to later higher-resolution surface spectral imaging. The SamCam will document the sample site before, during, and after it is disturbed by the sample mechanism. The PolyCam, using its focus mechanism, will observe the sample site at sub-centimeter resolutions, revealing surface texture and morphology. While their imaging requirements divide naturally between the three cameras, they preserve a strong degree of functional overlap. OCAMS and the other spacecraft instruments will allow the OSIRIS-REx mission to collect a sample from a microgravity body on the same visit during which it was first optically acquired from long range, a useful capability as humanity reaches out to explore near-Earth, Main-Belt and Jupiter Trojan asteroids.

  11. Enhancement of galaxy overdensity around quasar pairs at z < 3.6 based on the Hyper Suprime-Cam Subaru Strategic Program Survey

    NASA Astrophysics Data System (ADS)

    Onoue, Masafusa; Kashikawa, Nobunari; Uchiyama, Hisakazu; Akiyama, Masayuki; Harikane, Yuichi; Imanishi, Masatoshi; Komiyama, Yutaka; Matsuoka, Yoshiki; Nagao, Tohru; Nishizawa, Atsushi J.; Oguri, Masamune; Ouchi, Masami; Tanaka, Masayuki; Toba, Yoshiki; Toshikawa, Jun

    2018-01-01

    We investigate the galaxy overdensity around proto-cluster scale quasar pairs at high (z > 3) and low (z ˜ 1) redshift based on the unprecedentedly wide and deep optical survey of the Hyper Suprime-Cam Subaru Strategic Program (HSC-SSP). Using the first-year survey data covering effectively ˜121 deg2 with the 5σ depth of i ˜ 26.4 and the SDSS DR12Q catalog, we find two luminous pairs at z ˜ 3.3 and 3.6 which reside in >5σ overdensity regions of g-dropout galaxies at i < 25. The projected separations of the two pairs are R⊥ = 1.75 and 1.04 proper Mpc (pMpc), and their velocity offsets are ΔV = 692 and 1448 km s-1, respectively. This result is in clear contrast to the average z ˜ 4 quasar environments as discussed in Uchiyama et al. (2018, PASJ 70, S32) and implies that the quasar activities of the pair members are triggered via major mergers in proto-clusters, unlike the vast majority of isolated quasars in general fields that may turn on via non-merger events such as bar and disk instabilities. At z ˜ 1, we find 37 pairs with R⊥ < 2 pMpc and ΔV < 2300 km s-1 in the current HSC-Wide coverage, including four from Hennawi et al. (2006, AJ, 131, 1). The distribution of the peak overdensity significance within two arcminutes around the pairs has a long tail toward high-density (>4σ) regions. Thanks to the large sample size, we find statistical evidence that this excess is unique to the pair environments when compared to single-quasar and randomly selected galaxy environments at the same redshift range. Moreover, there are nine small-scale (R⊥ < 1 pMpc) pairs, two of which are found to reside in cluster fields. Our results demonstrate that <2 pMpc scale quasar pairs at both redshift ranges tend to occur in massive haloes, although perhaps not the most massive ones, and that they are useful in searching for rare density peaks.

  12. Mars Rock Rocknest 3 Imaged by Curiosity ChemCam

    NASA Image and Video Library

    2012-11-26

    This view of a rock called Rocknest 3 combines two images taken by the Chemistry and Camera ChemCam instrument on the NASA Mars rover Curiosity and indicates five spots where ChemCam had hit the rock with laser pulses to check its composition.

  13. JunoCam: A Public Endeavor

    NASA Astrophysics Data System (ADS)

    Hansen, Candice; Bolton, S.; Caplinger, M.; Dyches, P.; Jensen, E.; Levin, S.; Ravine, M.

    2012-10-01

    The camera on the Juno spacecraft is part of the payload specifically for public outreach. Juno’s JunoCam camera team will rely on public participation to accomplish our goals. Our theme is “science in a fishbowl” - execution of camera operation includes several amateur communities playing essential roles, and the public to help make decisions. JunoCam is a push-frame imager with 4 filters, built by Malin Space Science Systems (MSSS). It uses the Juno spacecraft rotation to sweep its field of view across the planet. Its wide field of view (58 deg) is optimized to take advantage of Juno’s polar orbit, yielding images of the poles with 50 km spatial scale. At perijove of Juno’s elliptical orbit images will have 3 km spatial scale. Jupiter is a dynamic planet - timely images of its cloudtops from amateur astronomers will be used to simulate what may be in the camera field of view at a given time. We are developing a website to organize contributions from amateur astronomers and tools to predict ahead where storms will be. Students will lead blog discussions (or the 2016 equivalent) on the merits of imaging any given target and the entire public is invited to weigh in on both the merits and the actual decision of what images to acquire. Images will be available within days for the public to process. The JunoCam team is relying on the amateur image processing community for color products, maps, and movies. When Junocam acquires images of the Earth in October 2013, we will use the opportunity to gain experience operating the instrument with public involvement. Although we will have a professional ops team at MSSS, the tiny size of the team overall means that the public participation is not just an extra - it is essential to our success.

  14. Auto-Focused on Details in Yellowjacket on Mars

    NASA Image and Video Library

    2015-05-22

    This image from the Chemistry and Camera (ChemCam) instrument on NASA's Curiosity Mars rover shows detailed texture of a rock target called "Yellowjacket" on Mars' Mount Sharp. This was the first rock target for ChemCam after checkout of restored capability for autonomous focusing. The image covers a patch of rock surface about 2.5 inches (6 centimeters) across. It was taken on May 15, 2015, during the mission's 986th Martian day, or sol. ChemCam's Remote Micro-Imager camera, on top of Curiosity's mast, captured the image from a distance of about 8 feet (2.4 meters). ChemCam also hit the target with laser pulses and recorded spectrographic information from the resulting flashes to reveal the chemical composition. Yellowjacket, located near an area called "Logan Pass" on lower Mount Sharp, is a layered sedimentary rock. The laser analysis yielded a composition very close to that of Mars soil and unlike the lakebed sedimentary compositions observed at lower elevations earlier in the mission. The soil-like composition may indicate that the rock formed from sediment transported by wind, rather than by water. http://photojournal.jpl.nasa.gov/catalog/PIA19661

  15. The ExoMars PanCam Instrument

    NASA Astrophysics Data System (ADS)

    Griffiths, Andrew; Coates, Andrew; Muller, Jan-Peter; Jaumann, Ralf; Josset, Jean-Luc; Paar, Gerhard; Barnes, David

    2010-05-01

    The ExoMars mission has evolved into a joint European-US mission to deliver a trace gas orbiter and a pair of rovers to Mars in 2016 and 2018 respectively. The European rover will carry the Pasteur exobiology payload including the 1.56 kg Panoramic Camera. PanCam will provide multispectral stereo images with 34 deg horizontal field-of-view (580 microrad/pixel) Wide-Angle Cameras (WAC) and (83 microrad/pixel) colour monoscopic "zoom" images with 5 deg horizontal field-of-view High Resolution Camera (HRC). The stereo Wide Angle Cameras (WAC) are based on Beagle 2 Stereo Camera System heritage [1]. Integrated with the WACs and HRC into the PanCam optical bench (which helps the instrument meet its planetary protection requirements) is the PanCam interface unit (PIU); which provides image storage, a Spacewire interface to the rover and DC-DC power conversion. The Panoramic Camera instrument is designed to fulfil the digital terrain mapping requirements of the mission [2] as well as providing multispectral geological imaging, colour and stereo panoramic images and solar images for water vapour abundance and dust optical depth measurements. The High Resolution Camera (HRC) can be used for high resolution imaging of interesting targets detected in the WAC panoramas and of inaccessible locations on crater or valley walls. Additionally HRC will be used to observe retrieved subsurface samples before ingestion into the rest of the Pasteur payload. In short, PanCam provides the overview and context for the ExoMars experiment locations, required to enable the exobiology aims of the mission. In addition to these baseline capabilities further enhancements are possible to PanCam to enhance it's effectiveness for astrobiology and planetary exploration: 1. Rover Inspection Mirror (RIM) 2. Organics Detection by Fluorescence Excitation (ODFE) LEDs [3-6] 3. UVIS broadband UV Flux and Opacity Determination (UVFOD) photodiode This paper will discuss the scientific objectives and resource

  16. Barratt with AgCam setup

    NASA Image and Video Library

    2009-04-16

    ISS019-E-007253 (16 April 2009) --- Astronaut Michael Barratt, Expedition 19/20 flight engineer, performs Agricultural Camera (AgCam) setup and activation in the Destiny laboratory of the International Space Station. AgCam takes frequent images, in visible and infrared light, of vegetated areas on Earth, such as farmland, rangeland, grasslands, forests and wetlands in the northern Great Plains and Rocky Mountain regions of the United States. Images will be delivered directly to requesting farmers, ranchers, foresters, natural resource managers and tribal officials to help improve environmental stewardship.

  17. The Computerized Anatomical Man (CAM) model

    NASA Technical Reports Server (NTRS)

    Billings, M. P.; Yucker, W. R.

    1973-01-01

    A computerized anatomical man (CAM) model, representing the most detailed and anatomically correct geometrical model of the human body yet prepared, has been developed for use in analyzing radiation dose distribution in man. This model of a 50-percentile standing USAF man comprises some 1100 unique geometric surfaces and some 2450 solid regions. Internal body geometry such as organs, voids, bones, and bone marrow are explicitly modeled. A computer program called CAMERA has also been developed for performing analyses with the model. Such analyses include tracing rays through the CAM geometry, placing results on magnetic tape in various forms, collapsing areal density data from ray tracing information to areal density distributions, preparing cross section views, etc. Numerous computer drawn cross sections through the CAM model are presented.

  18. The Mars NetLander panoramic camera

    NASA Astrophysics Data System (ADS)

    Jaumann, Ralf; Langevin, Yves; Hauber, Ernst; Oberst, Jürgen; Grothues, Hans-Georg; Hoffmann, Harald; Soufflot, Alain; Bertaux, Jean-Loup; Dimarellis, Emmanuel; Mottola, Stefano; Bibring, Jean-Pierre; Neukum, Gerhard; Albertz, Jörg; Masson, Philippe; Pinet, Patrick; Lamy, Philippe; Formisano, Vittorio

    2000-10-01

    The panoramic camera (PanCam) imaging experiment is designed to obtain high-resolution multispectral stereoscopic panoramic images from each of the four Mars NetLander 2005 sites. The main scientific objectives to be addressed by the PanCam experiment are (1) to locate the landing sites and support the NetLander network sciences, (2) to geologically investigate and map the landing sites, and (3) to study the properties of the atmosphere and of variable phenomena. To place in situ measurements at a landing site into a proper regional context, it is necessary to determine the lander orientation on ground and to exactly locate the position of the landing site with respect to the available cartographic database. This is not possible by tracking alone due to the lack of on-ground orientation and the so-called map-tie problem. Images as provided by the PanCam allow to determine accurate tilt and north directions for each lander and to identify the lander locations based on landmarks, which can also be recognized in appropriate orbiter imagery. With this information, it will be further possible to improve the Mars-wide geodetic control point network and the resulting geometric precision of global map products. The major geoscientific objectives of the PanCam lander images are the recognition of surface features like ripples, ridges and troughs, and the identification and characterization of different rock and surface units based on their morphology, distribution, spectral characteristics, and physical properties. The analysis of the PanCam imagery will finally result in the generation of precise map products for each of the landing sites. So far comparative geologic studies of the Martian surface are restricted to the timely separated Mars Pathfinder and the two Viking Lander Missions. Further lander missions are in preparation (Beagle-2, Mars Surveyor 03). NetLander provides the unique opportunity to nearly double the number of accessible landing site data by providing

  19. Portable retinal imaging for eye disease screening using a consumer-grade digital camera

    NASA Astrophysics Data System (ADS)

    Barriga, Simon; Larichev, Andrey; Zamora, Gilberto; Soliz, Peter

    2012-03-01

    The development of affordable means to image the retina is an important step toward the implementation of eye disease screening programs. In this paper we present the i-RxCam, a low-cost, hand-held, retinal camera for widespread applications such as tele-retinal screening for eye diseases like diabetic retinopathy (DR), glaucoma, and age-related ocular diseases. Existing portable retinal imagers do not meet the requirements of a low-cost camera with sufficient technical capabilities (field of view, image quality, portability, battery power, and ease-of-use) to be distributed widely to low volume clinics, such as the offices of single primary care physicians serving rural communities. The i-RxCam uses a Nikon D3100 digital camera body. The camera has a CMOS sensor with 14.8 million pixels. We use a 50mm focal lens that gives a retinal field of view of 45 degrees. The internal autofocus can compensate for about 2D (diopters) of focusing error. The light source is an LED produced by Philips with a linear emitting area that is transformed using a light pipe to the optimal shape at the eye pupil, an annulus. To eliminate corneal reflex we use a polarization technique in which the light passes through a nano-wire polarizer plate. This is a novel type of polarizer featuring high polarization separation (contrast ratio of more than 1000) and very large acceptance angle (>45 degrees). The i-RxCam approach will yield a significantly more economical retinal imaging device that would allow mass screening of the at-risk population.

  20. Applications of Action Cam Sensors in the Archaeological Yard

    NASA Astrophysics Data System (ADS)

    Pepe, M.; Ackermann, S.; Fregonese, L.; Fassi, F.; Adami, A.

    2018-05-01

    In recent years, special digital cameras called "action camera" or "action cam", have become popular due to their low price, smallness, lightness, strength and capacity to make videos and photos even in extreme environment surrounding condition. Indeed, these particular cameras have been designed mainly to capture sport actions and work even in case of dirt, bumps, or underwater and at different external temperatures. High resolution of Digital single-lens reflex (DSLR) cameras are usually preferred to be employed in photogrammetric field. Indeed, beyond the sensor resolution, the combination of such cameras with fixed lens with low distortion are preferred to perform accurate 3D measurements; at the contrary, action cameras have small and wide-angle lens, with a lower performance in terms of sensor resolution, lens quality and distortions. However, by considering the characteristics of the action cameras to acquire under conditions that may result difficult for standard DSLR cameras and because of their lower price, these could be taken into consideration as a possible and interesting approach during archaeological excavation activities to document the state of the places. In this paper, the influence of lens radial distortion and chromatic aberration on this type of cameras in self-calibration mode and an evaluation of their application in the field of Cultural Heritage will be investigated and discussed. Using a suitable technique, it has been possible to improve the accuracy of the 3D model obtained by action cam images. Case studies show the quality and the utility of the use of this type of sensor in the survey of archaeological artefacts.

  1. Exploring the Potential of a Wearable Camera to Examine the Early Obesogenic Home Environment: Comparison of SenseCam Images to the Home Environment Interview.

    PubMed

    Schrempft, Stephanie; van Jaarsveld, Cornelia Hm; Fisher, Abigail

    2017-10-12

    The obesogenic home environment is usually examined via self-report, and objective measures are required. This study explored whether the wearable camera SenseCam can be used to examine the early obesogenic home environment and whether it is useful for validation of self-report measures. A total of 15 primary caregivers of young children (mean age of child 4 years) completed the Home Environment Interview (HEI). Around 12 days after the HEI, participants wore the SenseCam at home for 4 days. A semistructured interview assessed participants' experience of wearing the SenseCam. Intraclass correlation coefficients (ICCs), percent agreement, and kappa statistics were used as validity estimates for 54 home environment features. Wearing the SenseCam was generally acceptable to those who participated. The SenseCam captured all 54 HEI features but with varying detail; 36 features (67%) had satisfactory validity (ICC or kappa ≥0.40; percent agreement ≥80 where kappa could not be calculated). Validity was good or excellent (ICC or kappa ≥0.60) for fresh fruit and vegetable availability, fresh vegetable variety, display of food and drink (except sweet snacks), family meals, child eating lunch or dinner while watching TV, garden and play equipment, the number of TVs and DVD players, and media equipment in the child's bedroom. Validity was poor (ICC or kappa <0.40) for tinned and frozen vegetable availability and variety, and sweet snack availability. The SenseCam has the potential to objectively examine and validate multiple aspects of the obesogenic home environment. Further research should aim to replicate the findings in a larger, representative sample. ©Stephanie Schrempft, Cornelia HM van Jaarsveld, Abigail Fisher. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 12.10.2017.

  2. Drilled Hole and ChemCam Marks at Cumberland

    NASA Image and Video Library

    2013-06-05

    The Chemistry and Camera ChemCam instrument on NASA Mars rover Curiosity was used to check the composition of gray tailings from the hole in rock target Cumberland that the rover drilled on May 19, 2013.

  3. ChemCam Mast Unit Being Prepared for Laser Firing

    NASA Image and Video Library

    2010-12-23

    Researchers prepare for a test of the Chemistry and Camera ChemCam instrument that will fly on NASA Mars Science Laboratory mission; researchers are preparing the instrument mast unit for a laser firing test.

  4. Modeled hydraulic redistribution in tree-grass, CAM-grass, and tree-CAM associations: the implications of crassulacean acid metabolism (CAM).

    PubMed

    Yu, Kailiang; Foster, Adrianna

    2016-04-01

    Past studies have largely focused on hydraulic redistribution (HR) in trees, shrubs, and grasses, and recognized its role in interspecies interactions. HR in plants that conduct crassulacean acid metabolism (CAM), however, remains poorly investigated, as does the effect of HR on transpiration in different vegetation associations (i.e., tree-grass, CAM-grass, and tree-CAM associations). We have developed a mechanistic model to investigate the net direction and magnitude of HR at the patch scale for tree-grass, CAM-grass, and tree-CAM associations at the growing season to yearly timescale. The modeling results show that deep-rooted CAM plants in CAM-grass associations could perform hydraulic lift at a higher rate than trees in tree-grass associations in a relatively wet environment, as explained by a significant increase in grass transpiration rate in the shallow soil layer, balancing a lower transpiration rate by CAM plants. By comparison, trees in tree-CAM associations may perform hydraulic descent at a higher rate than those in tree-grass associations in a dry environment. Model simulations also show that hydraulic lift increases the transpiration of shallow-rooted plants, while hydraulic descent increases that of deep-rooted plants. CAM plants transpire during the night and thus perform HR during the day. Based on these model simulations, we suggest that the ability of CAM plants to perform HR at a higher rate may have different effects on the surrounding plant community than those of plants with C3 or C4 photosynthetic pathways (i.e., diurnal transpiration).

  5. Using focused plenoptic cameras for rich image capture.

    PubMed

    Georgiev, T; Lumsdaine, A; Chunev, G

    2011-01-01

    This approach uses a focused plenoptic camera to capture the plenoptic function's rich "non 3D" structure. It employs two techniques. The first simultaneously captures multiple exposures (or other aspects) based on a microlens array having an interleaved set of different filters. The second places multiple filters at the main lens aperture.

  6. On the accuracy potential of focused plenoptic camera range determination in long distance operation

    NASA Astrophysics Data System (ADS)

    Sardemann, Hannes; Maas, Hans-Gerd

    2016-04-01

    Plenoptic cameras have found increasing interest in optical 3D measurement techniques in recent years. While their basic principle is 100 years old, the development in digital photography, micro-lens fabrication technology and computer hardware has boosted the development and lead to several commercially available ready-to-use cameras. Beyond their popular option of a posteriori image focusing or total focus image generation, their basic ability of generating 3D information from single camera imagery depicts a very beneficial option for certain applications. The paper will first present some fundamentals on the design and history of plenoptic cameras and will describe depth determination from plenoptic camera image data. It will then present an analysis of the depth determination accuracy potential of plenoptic cameras. While most research on plenoptic camera accuracy so far has focused on close range applications, we will focus on mid and long ranges of up to 100 m. This range is especially relevant, if plenoptic cameras are discussed as potential mono-sensorial range imaging devices in (semi-)autonomous cars or in mobile robotics. The results show the expected deterioration of depth measurement accuracy with depth. At depths of 30-100 m, which may be considered typical in autonomous driving, depth errors in the order of 3% (with peaks up to 10-13 m) were obtained from processing small point clusters on an imaged target. Outliers much higher than these values were observed in single point analysis, stressing the necessity of spatial or spatio-temporal filtering of the plenoptic camera depth measurements. Despite these obviously large errors, a plenoptic camera may nevertheless be considered a valid option for the application fields of real-time robotics like autonomous driving or unmanned aerial and underwater vehicles, where the accuracy requirements decrease with distance.

  7. Beliefs, decision-making, and dialogue about complementary and alternative medicine (CAM) within families using CAM: a qualitative study.

    PubMed

    Nichol, James; Thompson, Elizabeth A; Shaw, Alison

    2011-02-01

    The rise in complementary and alternative medicine (CAM) use is well documented. Surveys provide varying estimates of the prevalence of CAM use. Qualitative research has explored individuals' decision-making regarding CAM. This study aimed to examine the family as a context for beliefs, decision-making, and dialogue about CAM. Families were recruited via the Avon Longitudinal Study of Parents and Children. A subsample of CAM users was targeted using purposeful sampling. Focus groups and interviews were conducted with 15 families and the data were analyzed thematically. Family understandings and beliefs about CAM: CAM was understood as treatments provided outside mainstream care, offering a more "natural" and "holistic" approach, tailored to individual needs and overlapping with wider healthy lifestyle practices. Hierarchies of acceptability of CAM: Physical and "mainstream" therapies were widely supported, with "fringe" therapies producing the most polarized views. There was a belief particularly among fathers and young people that certain therapies rely on "placebo" effects and their value was contested. Types of CAM users within families: Family members were predominantly "pragmatic" CAM users, with "committed" users (all mothers) characterized by deeper philosophical commitment to CAM and skepticism toward conventional medicine. Family dynamics of CAM decision-making: Mothers tended to "champion" CAM within families, while not determining family CAM use. Fathers largely positioned themselves as lacking expertise or skeptical of CAM. Young people were beginning to articulate independent and more critical views of CAM, some directly challenging their mother's perspective. However, all families shared openness to CAM as part of broader beliefs in proactive healthy lifestyles. Family focus groups and interviews allow a window on beliefs, decision-making, and dialogue about CAM within families, illuminating the CAM "champion" role held by mothers, and young people

  8. JunoCam: Outreach and Science Opportunities

    NASA Astrophysics Data System (ADS)

    Hansen, Candice; Ingersoll, Andy; Caplinger, Mike; Ravine, Mike; Orton, Glenn

    2014-11-01

    JunoCam is a visible imager on the Juno spacecraft en route to Jupiter. Although the primary role of the camera is for outreach, science objectives will be addressed too. JunoCam is a wide angle camera (58 deg field of view) with 4 color filters: red, green and blue (RGB) and methane at 889 nm. Juno’s elliptical polar orbit will offer unique views of Jupiter’s polar regions with a spatial scale of ~50 km/pixel. The polar vortex, polar cloud morphology, and winds will be investigated. RGB color mages of the aurora will be acquired. Stereo images and images taken with the methane filter will allow us to estimate cloudtop heights. Resolution exceeds that of Cassini about an hour from closest approach and at closest approach images will have a spatial scale of ~3 km/pixel. JunoCam is a push-frame imager on a rotating spacecraft. The use of time-delayed integration takes advantage of the spacecraft spin to build up signal. JunoCam will acquire limb-to-limb views of Jupiter during a spacecraft rotation, and has the possibility of acquiring images of the rings from in-between Jupiter and the inner edge of the rings. Galilean satellite views will be fairly distant but some images will be acquired. Outer irregular satellites and small ring moons Metis and Adrastea will also be imaged. The theme of our outreach is “science in a fish bowl”, with an invitation to the science community and the public to participate. Amateur astronomers will supply their ground-based images for planning, so that we can predict when prominent atmospheric features will be visible. With the aid of professional astronomers observing at infrared wavelengths, we’ll predict when hot spots will be visible to JunoCam. Amateur image processing enthusiasts are onboard to create image products. Many of the earth flyby image products from Juno’s earth gravity assist were processed by amateurs. Between the planning and products will be the decision-making on what images to take when and why. We

  9. Xi-cam: Flexible High Throughput Data Processing for GISAXS

    NASA Astrophysics Data System (ADS)

    Pandolfi, Ronald; Kumar, Dinesh; Venkatakrishnan, Singanallur; Sarje, Abinav; Krishnan, Hari; Pellouchoud, Lenson; Ren, Fang; Fournier, Amanda; Jiang, Zhang; Tassone, Christopher; Mehta, Apurva; Sethian, James; Hexemer, Alexander

    With increasing capabilities and data demand for GISAXS beamlines, supporting software is under development to handle larger data rates, volumes, and processing needs. We aim to provide a flexible and extensible approach to GISAXS data treatment as a solution to these rising needs. Xi-cam is the CAMERA platform for data management, analysis, and visualization. The core of Xi-cam is an extensible plugin-based GUI platform which provides users an interactive interface to processing algorithms. Plugins are available for SAXS/GISAXS data and data series visualization, as well as forward modeling and simulation through HipGISAXS. With Xi-cam's advanced mode, data processing steps are designed as a graph-based workflow, which can be executed locally or remotely. Remote execution utilizes HPC or de-localized resources, allowing for effective reduction of high-throughput data. Xi-cam is open-source and cross-platform. The processing algorithms in Xi-cam include parallel cpu and gpu processing optimizations, also taking advantage of external processing packages such as pyFAI. Xi-cam is available for download online.

  10. Field Test of the ExoMars Panoramic Camera in the High Arctic - First Results and Lessons Learned

    NASA Astrophysics Data System (ADS)

    Schmitz, N.; Barnes, D.; Coates, A.; Griffiths, A.; Hauber, E.; Jaumann, R.; Michaelis, H.; Mosebach, H.; Paar, G.; Reissaus, P.; Trauthan, F.

    2009-04-01

    The ExoMars mission as the first element of the ESA Aurora program is scheduled to be launched to Mars in 2016. Part of the Pasteur Exobiology Payload onboard the ExoMars rover is a Panoramic Camera System (‘PanCam') being designed to obtain high-resolution color and wide-angle multi-spectral stereoscopic panoramic images from the mast of the ExoMars rover. The PanCam instrument consists of two wide-angle cameras (WACs), which will provide multispectral stereo images with 34° field-of-view (FOV) and a High-Resolution RGB Channel (HRC) to provide close-up images with 5° field-of-view. For field testing of the PanCam breadboard in a representative environment the ExoMars PanCam team joined the 6th Arctic Mars Analogue Svalbard Expedition (AMASE) 2008. The expedition took place from 4-17 August 2008 in the Svalbard archipelago, Norway, which is considered to be an excellent site, analogue to ancient Mars. 31 scientists and engineers involved in Mars Exploration (among them the ExoMars WISDOM, MIMA and Raman-LIBS team as well as several NASA MSL teams) combined their knowledge, instruments and techniques to study the geology, geophysics, biosignatures, and life forms that can be found in volcanic complexes, warm springs, subsurface ice, and sedimentary deposits. This work has been carried out by using instruments, a rover (NASA's CliffBot), and techniques that will/may be used in future planetary missions, thereby providing the capability to simulate a full mission environment in a Mars analogue terrain. Besides demonstrating PanCam's general functionality in a field environment, test and verification of the interpretability of PanCam data for in-situ geological context determination and scientific target selection was a main objective. To process the collected data, a first version of the preliminary PanCam 3D reconstruction processing & visualization chain was used. Other objectives included to test and refine the operational scenario (based on ExoMars Rover

  11. About Jupiter's Reflectance Function in JunoCam Images

    NASA Astrophysics Data System (ADS)

    Eichstaedt, G.; Orton, G. S.; Momary, T.; Hansen, C. J.; Caplinger, M.

    2017-09-01

    NASA's Juno spacecraft has successfully completed several perijove passes. JunoCam is Juno's visible light and infrared camera. It was added to the instrument complement to investigate Jupiter's polar regions, and for education and public outreach purposes. Images of Jupiter taken by JunoCam have been revealing effects that can be interpreted as caused by a haze layer. This presumed haze layer appears to be structured, and it partially obscures Jupiter's cloud top. With empirical investigation of Jupiter's reflectance function we intend to separate light contributed by haze from light reflected off Jupiter's cloud tops, enabling both layers to be investigated separately.

  12. Curiosity's ChemCam Checks 'Christmas Cove' Colors

    NASA Image and Video Library

    2017-11-01

    The Chemistry and Camera (ChemCam) instrument on NASA's Curiosity Mars rover examined a freshly brushed area on target rock "Christmas Cove" and found spectral evidence of hematite, an iron-oxide mineral. ChemCam sometimes zaps rocks with a laser, but can also be used, as in this case, in a "passive" mode. In this type of investigation, the instrument's telescope delivers to spectrometers the sunlight reflected from a small target point. The upper-left inset of this graphic is an image from ChemCam's Remote Micro-Imager with five labeled points that the instrument analyzed. The image covers an area about 2 inches (5 centimeters) wide, and the bright lines are fractures in the rock filled with calcium sulfate minerals. The five charted lines of the graphic correspond to those five points and show the spectrometer measurements of brightness at thousands of different wavelengths, from 400 nanometers (at the violet end of the visible-light spectrum) to 840 nanometers (in near-infrared). Sections of the spectrum measurements that are helpful for identifying hematite are annotated. These include a dip around 535 nanometers, the green-light portion of the spectrum at which fine-grained hematite tends to absorb more light and reflect less compared to other parts of the spectrum. That same green-absorbing characteristic of the hematite makes it appear purplish when imaged through special filters of Curiosity's Mast Camera and even in usual color images. The spectra also show maximum reflectance values near 750 nanometers, followed by a steep decrease in the spectral slope toward 840 nanometers, both of which are consistent with hematite. This ChemCam examination of Christmas Cove was part of an experiment to determine whether the rock had evidence of hematite under a tan coating of dust. The target area was brushed with Curiosity's Dust Removal Tool prior to these ChemCam passive observations on Sept. 17, 2017, during the 1,819th Martian day, or sol, of Curiosity's work on

  13. Metric Calibration of a Focused Plenoptic Camera Based on a 3d Calibration Target

    NASA Astrophysics Data System (ADS)

    Zeller, N.; Noury, C. A.; Quint, F.; Teulière, C.; Stilla, U.; Dhome, M.

    2016-06-01

    In this paper we present a new calibration approach for focused plenoptic cameras. We derive a new mathematical projection model of a focused plenoptic camera which considers lateral as well as depth distortion. Therefore, we derive a new depth distortion model directly from the theory of depth estimation in a focused plenoptic camera. In total the model consists of five intrinsic parameters, the parameters for radial and tangential distortion in the image plane and two new depth distortion parameters. In the proposed calibration we perform a complete bundle adjustment based on a 3D calibration target. The residual of our optimization approach is three dimensional, where the depth residual is defined by a scaled version of the inverse virtual depth difference and thus conforms well to the measured data. Our method is evaluated based on different camera setups and shows good accuracy. For a better characterization of our approach we evaluate the accuracy of virtual image points projected back to 3D space.

  14. Earth's Radiation Belts: The View from Juno's Cameras

    NASA Astrophysics Data System (ADS)

    Becker, H. N.; Joergensen, J. L.; Hansen, C. J.; Caplinger, M. A.; Ravine, M. A.; Gladstone, R.; Versteeg, M. H.; Mauk, B.; Paranicas, C.; Haggerty, D. K.; Thorne, R. M.; Connerney, J. E.; Kang, S. S.

    2013-12-01

    Juno's cameras, particle instruments, and ultraviolet imaging spectrograph have been heavily shielded for operation within Jupiter's high radiation environment. However, varying quantities of >1-MeV electrons and >10-MeV protons will be energetic enough to penetrate instrument shielding and be detected as transient background signatures by the instruments. The differing shielding profiles of Juno's instruments lead to differing spectral sensitivities to penetrating electrons and protons within these regimes. This presentation will discuss radiation data collected by Juno in the Earth's magnetosphere during Juno's October 9, 2013 Earth flyby (559 km altitude at closest approach). The focus will be data from Juno's Stellar Reference Unit, Advanced Stellar Compass star cameras, and JunoCam imager acquired during coordinated proton measurements within the inner zone and during the spacecraft's inbound and outbound passages through the outer zone (L ~3-5). The background radiation signatures from these cameras will be correlated with dark count background data collected at these geometries by Juno's Ultraviolet Spectrograph (UVS) and Jupiter Energetic Particle Detector Instrument (JEDI). Further comparison will be made to Van Allen Probe data to calibrate Juno's camera results and contribute an additional view of the Earth's radiation environment during this unique event.

  15. The smartphone as a platform for wearable cameras in health research.

    PubMed

    Gurrin, Cathal; Qiu, Zhengwei; Hughes, Mark; Caprani, Niamh; Doherty, Aiden R; Hodges, Steve E; Smeaton, Alan F

    2013-03-01

    The Microsoft SenseCam, a small camera that is worn on the chest via a lanyard, increasingly is being deployed in health research. However, the SenseCam and other wearable cameras are not yet in widespread use because of a variety of factors. It is proposed that the ubiquitous smartphones can provide a more accessible alternative to SenseCam and similar devices. To perform an initial evaluation of the potential of smartphones to become an alternative to a wearable camera such as the SenseCam. In 2012, adults were supplied with a smartphone, which they wore on a lanyard, that ran life-logging software. Participants wore the smartphone for up to 1 day and the resulting life-log data were both manually annotated and automatically analyzed for the presence of visual concepts. The results were compared to prior work using the SenseCam. In total, 166,000 smartphone photos were gathered from 47 individuals, along with associated sensor readings. The average time spent wearing the device across all users was 5 hours 39 minutes (SD=4 hours 11 minutes). A subset of 36,698 photos was selected for manual annotation by five researchers. Software analysis of these photos supports the automatic identification of activities to a similar level of accuracy as for SenseCam images in a previous study. Many aspects of the functionality of a SenseCam largely can be replicated, and in some cases enhanced, by the ubiquitous smartphone platform. This makes smartphones good candidates for a new generation of wearable sensing devices in health research, because of their widespread use across many populations. It is envisioned that smartphones will provide a compelling alternative to the dedicated SenseCam hardware for a number of users and application areas. This will be achieved by integrating new types of sensor data, leveraging the smartphone's real-time connectivity and rich user interface, and providing support for a range of relatively sophisticated applications. Copyright © 2013

  16. AEGIS Automated Targeting for the MSL ChemCam Instrument

    NASA Astrophysics Data System (ADS)

    Estlin, T.; Anderson, R. C.; Blaney, D. L.; Bornstein, B.; Burl, M. C.; Castano, R.; Gaines, D.; Judd, M.; Thompson, D. R.; Wiens, R. C.

    2013-12-01

    The Autonomous Exploration for Gathering Increased Science (AEGIS) system enables automated science data collection by a planetary rover. AEGIS has been in use on the Mars Exploration Rover (MER) mission Opportunity rover since 2010 to provide onboard targeting of the MER Panoramic Camera based on scientist-specified objectives. AEGIS is now being applied for use with the Mars Science Laboratory (MSL) mission ChemCam spectrometer. ChemCam uses a Laser Induced Breakdown Spectrometer (LIBS) to analyze the elemental composition of rocks and soil from up to seven meters away. ChemCam's tightly-focused laser beam (350-550 um) enables targeting of very fine-scale terrain features. AEGIS is being applied in two ways to help ChemCam collect valuable science data. The first application is to enable automated targeting of ChemCam during or after or in the middle of long drives. The majority of ChemCam measurements are collected by allowing the science team to select specific targets in rover images. However this requires the rover to stay in the same area while images are downlinked, analyzed for targets, and new commands uplinked. The only data that can be acquired without this communication cycle is via blind targeting, where measurements are often of soil patches vs. instead of more valuable targets such as rocks with specific properties. AEGIS is being applied to automatically analyze images onboard and select targets for ChemCam analysis. This approach allows the rover to autonomously select and sequence targeted measurements in an opportunistic fashion at different points along the rover's drive path. Rock targets can be prioritized for measurement based on various geologically relevant features, including size, shape and albedo. A second application is to enable intelligent pointing refinement of ChemCam when acquiring data of small targets, such as veins or concretions that are only a few millimeters wide. Due to backlash and other pointing challenges, it can often

  17. Variable-focus liquid lens for miniature cameras

    NASA Astrophysics Data System (ADS)

    Kuiper, S.; Hendriks, B. H. W.

    2004-08-01

    The meniscus between two immiscible liquids can be used as an optical lens. A change in curvature of this meniscus by electrowetting leads to a change in focal distance. It is demonstrated that two liquids in a tube form a self-centered lens with a high optical quality. The motion of the lens during a focusing action was studied by observation through the transparent tube wall. Finally, a miniature achromatic camera module was designed and constructed based on this adjustable lens, showing that it is excellently suited for use in portable applications.

  18. Fluorometric Biosniffer Camera "Sniff-Cam" for Direct Imaging of Gaseous Ethanol in Breath and Transdermal Vapor.

    PubMed

    Arakawa, Takahiro; Sato, Toshiyuki; Iitani, Kenta; Toma, Koji; Mitsubayashi, Kohji

    2017-04-18

    Various volatile organic compounds can be found in human transpiration, breath and body odor. In this paper, a novel two-dimensional fluorometric imaging system, known as a "sniffer-cam" for ethanol vapor released from human breath and palm skin was constructed and validated. This imaging system measures ethanol vapor concentrations as intensities of fluorescence through an enzymatic reaction induced by alcohol dehydrogenase (ADH). The imaging system consisted of multiple ultraviolet light emitting diode (UV-LED) excitation sheet, an ADH enzyme immobilized mesh substrate and a high-sensitive CCD camera. This imaging system uses ADH for recognition of ethanol vapor. It measures ethanol vapor by measuring fluorescence of nicotinamide adenine dinucleotide (NADH), which is produced by an enzymatic reaction on the mesh. This NADH fluorometric imaging system achieved the two-dimensional real-time imaging of ethanol vapor distribution (0.5-200 ppm). The system showed rapid and accurate responses and a visible measurement, which could lead to an analysis of metabolism function at real time in the near future.

  19. Visible camera cryostat design and performance for the SuMIRe Prime Focus Spectrograph (PFS)

    NASA Astrophysics Data System (ADS)

    Smee, Stephen A.; Gunn, James E.; Golebiowski, Mirek; Hope, Stephen C.; Madec, Fabrice; Gabriel, Jean-Francois; Loomis, Craig; Le fur, Arnaud; Dohlen, Kjetil; Le Mignant, David; Barkhouser, Robert; Carr, Michael; Hart, Murdock; Tamura, Naoyuki; Shimono, Atsushi; Takato, Naruhisa

    2016-08-01

    We describe the design and performance of the SuMIRe Prime Focus Spectrograph (PFS) visible camera cryostats. SuMIRe PFS is a massively multi-plexed ground-based spectrograph consisting of four identical spectrograph modules, each receiving roughly 600 fibers from a 2394 fiber robotic positioner at the prime focus. Each spectrograph module has three channels covering wavelength ranges 380 nm - 640 nm, 640 nm - 955 nm, and 955 nm - 1.26 um, with the dispersed light being imaged in each channel by a f/1.07 vacuum Schmidt camera. The cameras are very large, having a clear aperture of 300 mm at the entrance window, and a mass of 280 kg. In this paper we describe the design of the visible camera cryostats and discuss various aspects of cryostat performance.

  20. Feasibility of a SenseCam-assisted 24-h recall to reduce under-reporting of energy intake.

    PubMed

    Gemming, L; Doherty, A; Kelly, P; Utter, J; Ni Mhurchu, C

    2013-10-01

    The SenseCam is a camera worn on a lanyard around the neck that automatically captures point-of-view images in response to movement, heat and light (every 20-30 s). This device may enhance the accuracy of self-reported dietary intake by assisting participants' recall of food and beverage consumption. It was the objective of this study to evaluate if the wearable camera, SenseCam, can enhance the 24-h dietary recall by providing visual prompts to improve recall of food and beverage consumption. Thirteen volunteer adults in Oxford, United Kingdom, were recruited. Participants wore the SenseCam for 2 days while continuing their usual daily activities. On day 3, participants' diets were assessed using an interviewer-administered 24-h recall. SenseCam images were then shown to the participants and any additional dietary information that participants provided after viewing the images was recorded. Energy and macronutrient intakes were compared between the 24-h recall and 24-h recall+SenseCam. Data from 10 participants were included in the final analysis (8 males and 2 females), mean age 33 ± 11 years, mean BMI 25.9 ± 5.1 kg/m(2). Viewing the SenseCam images increased self-reported energy intake by approximately 1432 ± 1564 kJ or 12.5% compared with the 24-h recall alone (P=0.02). The increase was predominantly due to reporting of 41 additional foods (241 vs 282 total foods) across a range of food groups. Eight changes in portion size were made, which resulted in a negligible change to energy intake. Wearable cameras are promising method to enhance the accuracy of self-reported dietary assessment methods.

  1. The Camera of the MASCOT Asteroid Lander on Board Hayabusa 2

    NASA Astrophysics Data System (ADS)

    Jaumann, R.; Schmitz, N.; Koncz, A.; Michaelis, H.; Schroeder, S. E.; Mottola, S.; Trauthan, F.; Hoffmann, H.; Roatsch, T.; Jobs, D.; Kachlicki, J.; Pforte, B.; Terzer, R.; Tschentscher, M.; Weisse, S.; Mueller, U.; Perez-Prieto, L.; Broll, B.; Kruselburger, A.; Ho, T.-M.; Biele, J.; Ulamec, S.; Krause, C.; Grott, M.; Bibring, J.-P.; Watanabe, S.; Sugita, S.; Okada, T.; Yoshikawa, M.; Yabuta, H.

    2017-07-01

    and those made by the in-situ measurements. The MasCam is mounted inside the lander slightly tilted, such that the center of its 54.8° square field-of-view is directed towards the surface at an angle of 22° with respect to the surface plane. This is to ensure that both the surface close to the lander and the horizon are observable. The camera optics is designed according to the Scheimpflug principle, thus that the entire scene along the camera's depth of field (150 mm to infinity) is in focus. The camera utilizes a 1024×1024 pixel CMOS sensor sensitive in the 400-1000 nm wavelength range, peaking at 600-700 nm. Together with the f-16 optics, this yields a nominal ground resolution of 150 micron/px at 150 mm distance (diffraction limited). The camera flight model has undergone standard radiometric and geometric calibration both at the component and system (lander) level. MasCam relies on the use of wavelet compression to maximize data return within stringent mission downlink limits. All calibration and flight data products will be generated and archived in the Planetary Data System in PDS image format.

  2. Characterization of TimepixCam, a fast imager for the time-stamping of optical photons

    NASA Astrophysics Data System (ADS)

    Nomerotski, Andrei; Chakaberia, I.; Fisher-Levine, M.; Janoska, Z.; Takacs, P.; Tsang, T.

    2017-01-01

    We describe the characterization of TimepixCam, a novel camera used to time-stamp optical photons. The camera employs a specialized silicon sensor with a thin entrance window, read out by a Timepix ASIC. TimepixCam is able to record and time-stamp light flashes exceeding 1,000 photons with 15 ns time resolution. Specially produced photodiodes were used to evaluate the quantum efficiency, which was determined to be higher than 90% in the wavelength range of 430-900 nm. The quantum efficiency, sensitivity and ion detection efficiency were compared for a variety of sensors with different surface treatments. Sensors with the thinnest window, 50 nm, had the best performance.

  3. JunoCam: Science and Outreach Opportunities with Juno

    NASA Astrophysics Data System (ADS)

    Hansen, C. J.; Orton, G. S.

    2015-12-01

    JunoCam is a visible imager on the Juno spacecraft en route to Jupiter. Although the primary role of the camera is for outreach, science objectives will be addressed too. JunoCam is a wide angle camera (58 deg field of view) with 4 color filters: red, green and blue (RGB) and methane at 889 nm. Juno's elliptical polar orbit will offer unique views of Jupiter's polar regions with a spatial scale of ~50 km/pixel. The polar vortex, polar cloud morphology, and winds will be investigated. RGB color mages of the aurora will be acquired. Stereo images and images taken with the methane filter will allow us to estimate cloudtop heights. Resolution exceeds that of Cassini about an hour from closest approach and at closest approach images will have a spatial scale of ~3 km/pixel. JunoCam is a push-frame imager on a rotating spacecraft. The use of time-delayed integration takes advantage of the spacecraft spin to build up signal. JunoCam will acquire limb-to-limb views of Jupiter during a spacecraft rotation, and has the possibility of acquiring images of the rings from in-between Jupiter and the inner edge of the rings. Galilean satellite views will be fairly distant but some images will be acquired. Small ring moons Metis and Adrastea will also be imaged. The theme of our outreach is "science in a fish bowl", with an invitation to the science community and the public to participate. Amateur astronomers will supply their ground-based images for planning, so that we can predict when prominent atmospheric features will be visible. With the aid of professional astronomers observing at infrared wavelengths, we'll predict when hot spots will be visible to JunoCam. Amateur image processing enthusiasts are prepared to create image products. Between the planning and products will be the decision-making on what images to take when and why. We invite our colleagues to propose science questions for JunoCam to address, and to be part of the participatory process of deciding how to use

  4. The UV Survey Mission Concept, CETUS

    NASA Astrophysics Data System (ADS)

    Heap, Sara; and the CETUS Team

    2018-01-01

    In March 2017, NASA selected CETUS for study of a Probe-class mission concept. W. Danchi is the CETUS PI, and S. Heap is the Science PI. CETUS is primarily a UV survey telescope to complement survey telescopes of the 2020’s including E-ROSITA, Subaru Hyper Suprime Cam and Prime-Focus Spectrograph, WFIRST, and the Square Kilometer Array. CETUS comprises a 1.5-m wide-field telescope and three science instruments: a wide-field (1045” on a side) far-UV and near-UV camera; a similarly wide-field near-UV multi-object spectrograph utilizing a next-generation micro-shutter array; and a single-object spectrograph with options of spectral region (far-UV or near-UV) and spectral resolving power (2,000 or 40,000). The survey instruments will operate simultaneously thereby producing wide-field images in the near-UV and far-UV and a spectrogram containing near-UV spectra of up to 100 sources free of spectral overlap and astronomical background. ln concert with other survey telescopes, CETUS will focus on understanding galaxy evolution at cosmic noon (z~1-2).

  5. L1CAM in human cancer.

    PubMed

    Altevogt, Peter; Doberstein, Kai; Fogel, Mina

    2016-04-01

    L1 cell adhesion molecule (L1CAM) is one of the first neural adhesion molecules described with important functions in the development of the nervous system. Subsequent work discovered that L1CAM is expressed in many human cancers and is often associated with bad prognosis. This is most likely due to the motility and invasion promoting function of L1CAM. Here, we describe the path L1CAM has taken from a neural adhesion molecule to a recognized tumor antigen. We summarize the literature on L1CAM expression in cancers and pre-cancerous lesions. We focus on the genetic elements required for its re-expression and highlight preclinical studies for targeted therapy. The data suggest that L1CAM is a valuable diagnostic/prognostic marker and an attractive target for the therapy of several human cancers. © 2015 UICC.

  6. Next Generation CAD/CAM/CAE Systems

    NASA Technical Reports Server (NTRS)

    Noor, Ahmed K. (Compiler); Malone, John B. (Compiler)

    1997-01-01

    This document contains presentations from the joint UVA/NASA Workshop on Next Generation CAD/CAM/CAE Systems held at NASA Langley Research Center in Hampton, Virginia on March 18-19, 1997. The presentations focused on current capabilities and future directions of CAD/CAM/CAE systems, aerospace industry projects, and university activities related to simulation-based design. Workshop attendees represented NASA, commercial software developers, the aerospace industry, government labs, and academia. The workshop objectives were to assess the potential of emerging CAD/CAM/CAE technology for use in intelligent simulation-based design and to provide guidelines for focused future research leading to effective use of CAE systems for simulating the entire life cycle of aerospace systems.

  7. Using Microporous Polytetrafluoroethylene Thin Sheets as a Flexible Solar Diffuser to Minimize Sunlight Glint to Cameras in Space

    NASA Technical Reports Server (NTRS)

    Choi, Michael K.

    2016-01-01

    An innovative design of using microporous PTFE thin sheets as a solar diffuser for MLI blankets or mechanical structure has been developed. It minimizes sunlight or stray-light glint to cameras when it is incident on these components in space. A microporous black PTFE thin sheet solar diffuser has been qualified for flight at NASA GSFC and installed to the TAGSAM arm MLI, OCAMS PolyCam sunshade MLI and SamCam motor riser MLI in the NASA OSIRIS-REx mission to meet the SamCam camera BRDF requirement.

  8. Using microporous polytetrafluoroethylene thin sheets as a flexible solar diffuser to minimize sunlight glint to cameras in space

    NASA Astrophysics Data System (ADS)

    Choi, Michael K.

    2016-09-01

    An innovative design of using microporous PTFE thin sheets as a solar diffuser for MLI blankets or mechanical structure has been developed. It minimizes sunlight or stray-light glint to cameras when it is incident on these components in space. A microporous black PTFE thin sheet solar diffuser has been qualified for flight at NASA GSFC and installed to the TAGSAM arm MLI, OCAMS PolyCam sunshade MLI and SamCam motor riser MLI in the NASA OSIRIS-REx mission to meet the SamCam camera BRDF requirement.

  9. Characterization of TimepixCam, a fast imager for the time-stamping of optical photons

    DOE PAGES

    Nomerotski, Andrei; Chakaberia, I.; Fisher-Levine, M.; ...

    2017-01-04

    Here we describe the characterization of TimepixCam, a novel camera used to time-stamp optical photons. The camera employs a specialized silicon sensor with a thin entrance window, read out by a Timepix ASIC. TimepixCam is able to record and time-stamp light flashes exceeding 1,000 photons with 15 ns time resolution. Specially produced photodiodes were used to evaluate the quantum efficiency, which was determined to be higher than 90% in the wavelength range of 430–900 nm. The quantum efficiency, sensitivity and ion detection efficiency were compared for a variety of sensors with different surface treatments. We found sensors with the thinnestmore » window, 50 nm, had the best performance.« less

  10. Characterization of TimepixCam, a fast imager for the time-stamping of optical photons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nomerotski, Andrei; Chakaberia, I.; Fisher-Levine, M.

    Here we describe the characterization of TimepixCam, a novel camera used to time-stamp optical photons. The camera employs a specialized silicon sensor with a thin entrance window, read out by a Timepix ASIC. TimepixCam is able to record and time-stamp light flashes exceeding 1,000 photons with 15 ns time resolution. Specially produced photodiodes were used to evaluate the quantum efficiency, which was determined to be higher than 90% in the wavelength range of 430–900 nm. The quantum efficiency, sensitivity and ion detection efficiency were compared for a variety of sensors with different surface treatments. We found sensors with the thinnestmore » window, 50 nm, had the best performance.« less

  11. Time-resolved spectra of dense plasma focus using spectrometer, streak camera, and CCD combination.

    PubMed

    Goldin, F J; Meehan, B T; Hagen, E C; Wilkins, P R

    2010-10-01

    A time-resolving spectrographic instrument has been assembled with the primary components of a spectrometer, image-converting streak camera, and CCD recording camera, for the primary purpose of diagnosing highly dynamic plasmas. A collection lens defines the sampled region and couples light from the plasma into a step index, multimode fiber which leads to the spectrometer. The output spectrum is focused onto the photocathode of the streak camera, the output of which is proximity-coupled to the CCD. The spectrometer configuration is essentially Czerny-Turner, but off-the-shelf Nikon refraction lenses, rather than mirrors, are used for practicality and flexibility. Only recently assembled, the instrument requires significant refinement, but has now taken data on both bridge wire and dense plasma focus experiments.

  12. Occultation and Triangulation Camera (OcTriCam) Cubesat

    NASA Astrophysics Data System (ADS)

    Batchelor, D. A.

    2018-02-01

    A camera at Earth-Moon L2 would provide a 240,000 km triangulation baseline to augment near-Earth object observations with Earth-based telescopes such as Pan-STARRS, and planetary occultation research to refine ephemerides and probe ring systems.

  13. Memory for staged events: Supporting older and younger adults' memory with SenseCam.

    PubMed

    Mair, Ali; Poirier, Marie; Conway, Martin A

    2018-03-01

    Two experiments measured the effect of retrieval support provided by a wearable camera, SenseCam, on older and younger adults' memory for a recently experienced complex staged event. In each experiment, participants completed a series of tasks in groups, and the events were recalled 2 weeks later, after viewing SenseCam images (experimental condition) or thinking about the event (control condition). When IQ and education were matched, young adults recalled more event details than older adults, demonstrating an age-related deficit for novel autobiographical material. Reviewing SenseCam images increased the number of details recalled by older and younger adults, and the effect was similar for both groups. These results suggest that memory can be supported by the use of SenseCam, but the age-related deficit is not eliminated.

  14. Fixed-focus camera objective for small remote sensing satellites

    NASA Astrophysics Data System (ADS)

    Topaz, Jeremy M.; Braun, Ofer; Freiman, Dov

    1993-09-01

    An athermalized objective has been designed for a compact, lightweight push-broom camera which is under development at El-Op Ltd. for use in small remote-sensing satellites. The high performance objective has a fixed focus setting, but maintains focus passively over the full range of temperatures encountered in small satellites. The lens is an F/5.0, 320 mm focal length Tessar type, operating over the range 0.5 - 0.9 micrometers . It has a 16 degree(s) field of view and accommodates various state-of-the-art silicon detector arrays. The design and performance of the objective is described in this paper.

  15. Time-resolved ion imaging at free-electron lasers using TimepixCam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fisher-Levine, Merlin; Boll, Rebecca; Ziaee, Farzaneh

    In this paper, the application of a novel fast optical-imaging camera, TimepixCam, to molecular photoionization experiments using the velocity-map imaging technique at a free-electron laser is described. TimepixCam is a 256 × 256 pixel CMOS camera that is able to detect and time-stamp ion hits with 20 ns timing resolution, thus making it possible to record ion momentum images for all fragment ions simultaneously and avoiding the need to gate the detector on a single fragment. This allows the recording of significantly more data within a given amount of beam time and is particularly useful for pump–probe experiments, where drifts,more » for example, in the timing and pulse energy of the free-electron laser, severely limit the comparability of pump–probe scans for different fragments taken consecutively. Finally, in principle, this also allows ion–ion covariance or coincidence techniques to be applied to determine angular correlations between fragments.« less

  16. Time-resolved ion imaging at free-electron lasers using TimepixCam

    DOE PAGES

    Fisher-Levine, Merlin; Boll, Rebecca; Ziaee, Farzaneh; ...

    2018-02-20

    In this paper, the application of a novel fast optical-imaging camera, TimepixCam, to molecular photoionization experiments using the velocity-map imaging technique at a free-electron laser is described. TimepixCam is a 256 × 256 pixel CMOS camera that is able to detect and time-stamp ion hits with 20 ns timing resolution, thus making it possible to record ion momentum images for all fragment ions simultaneously and avoiding the need to gate the detector on a single fragment. This allows the recording of significantly more data within a given amount of beam time and is particularly useful for pump–probe experiments, where drifts,more » for example, in the timing and pulse energy of the free-electron laser, severely limit the comparability of pump–probe scans for different fragments taken consecutively. Finally, in principle, this also allows ion–ion covariance or coincidence techniques to be applied to determine angular correlations between fragments.« less

  17. Time-resolved ion imaging at free-electron lasers using TimepixCam.

    PubMed

    Fisher-Levine, Merlin; Boll, Rebecca; Ziaee, Farzaneh; Bomme, Cédric; Erk, Benjamin; Rompotis, Dimitrios; Marchenko, Tatiana; Nomerotski, Andrei; Rolles, Daniel

    2018-03-01

    The application of a novel fast optical-imaging camera, TimepixCam, to molecular photoionization experiments using the velocity-map imaging technique at a free-electron laser is described. TimepixCam is a 256 × 256 pixel CMOS camera that is able to detect and time-stamp ion hits with 20 ns timing resolution, thus making it possible to record ion momentum images for all fragment ions simultaneously and avoiding the need to gate the detector on a single fragment. This allows the recording of significantly more data within a given amount of beam time and is particularly useful for pump-probe experiments, where drifts, for example, in the timing and pulse energy of the free-electron laser, severely limit the comparability of pump-probe scans for different fragments taken consecutively. In principle, this also allows ion-ion covariance or coincidence techniques to be applied to determine angular correlations between fragments.

  18. Hundred lightcurves of sub-km main-belt asteroids

    NASA Astrophysics Data System (ADS)

    Yoshida, F.; Souami, D.; Bouquillon, S.; Nakamura, T.; Dermawan, B.; Yagi, M.; Souchay, J.

    2014-07-01

    We observed a single sky field near opposition and near the ecliptic plane using the Subaru telescope equipped with the Suprime-Cam. Taking advantage of the wide field of view (FOV) for the Suprime-Cam, the plan was to obtain 100 lightcurves of asteroids at the same time. The total observing time interval was about 8 hours on September 2, 2002, with 2-min exposures. We detected 147 moving objects in the single FOV (34'×27') on the Suprime-Cam (see Figure). Of those, 112 detections corresponded to different objects. We used the R filter during almost the entire observing run, but we took a few images with the B filter at the beginning, the middle, and the end of the run. We classified main-belt asteroids into S- and C-complexes with the B-R color of the object (Yoshida & Nakamura 2007). Although we carefully avoided regions of bright stars, the sky in the images taken by Suprime-Cam were actually crowded with faint objects. Therefore, the asteroids overlapped with background stars very often. Thus, it was very difficult to get lightcurves with high accuracy. We modified the GAIA-GBOT (Ground Based Optical Tracking) PIPELINE to measure the position and brightness of each object (Bouquillon et al. 2012). Once the objects were identified and their positions measured in pixel coordinates, the pipeline proceeded to the astrometric calibration and then to the photometric calibrations with the Guide Star Catalog II (Lasker et al. 2008). The pipeline produced time series of photometry for each object. The average brightness of each lightcurve ranged between 19--24 mag. We then estimated the rotational period from the lightcurve of each object. In our presentation, we will show the spin-period distribution of sub- km main-belt asteroids and compare it with that of large main-belt asteroids obtained from the lightcurve catalogue.

  19. TimepixCam: a fast optical imager with time-stamping

    NASA Astrophysics Data System (ADS)

    Fisher-Levine, M.; Nomerotski, A.

    2016-03-01

    We describe a novel fast optical imager, TimepixCam, based on an optimized silicon pixel sensor with a thin entrance window, read out by a Timepix ASIC. TimepixCam is able to record and time-stamp light flashes in excess of 1,000 photons with high quantum efficiency in the 400-1000nm wavelength range with 20ns timing resolution, corresponding to an effective rate of 50 Megaframes per second. The camera was used for imaging ions impinging on a microchannel plate followed by a phosphor screen. Possible applications include spatial and velocity map imaging of ions in time-of-flight mass spectroscopy; coincidence imaging of ions and electrons, and other time-resolved types of imaging spectroscopy.

  20. [Intraoperative augmented reality visualization. Current state of development and initial experiences with the CamC].

    PubMed

    Weidert, S; Wang, L; von der Heide, A; Navab, N; Euler, E

    2012-03-01

    The intraoperative application of augmented reality (AR) has so far mainly taken place in the field of endoscopy. Here, the camera image of the endoscope was augmented by computer graphics derived mostly from preoperative imaging. Due to the complex setup and operation of the devices, they have not yet become part of routine clinical practice. The Camera Augmented Mobile C-arm (CamC) that extends a classic C-arm by a video camera and mirror construction is characterized by its uncomplicated handling. It combines its video live stream geometrically correct with the acquired X-ray. The clinical application of the device in 43 cases showed the strengths of the device in positioning for X-ray acquisition, incision placement, K-wire placement, and instrument guidance. With its new function and the easy integration into the OR workflow of any procedure that requires X-ray imaging, the CamC has the potential to become the first widely used AR technology for orthopedic and trauma surgery.

  1. "Baby-Cam" and Researching with Infants: Viewer, Image and (Not) Knowing

    ERIC Educational Resources Information Center

    Elwick, Sheena

    2015-01-01

    This article offers a methodological reflection on how "baby-cam" enhanced ethically reflective attitudes in a large-scale research project that set out to research with infants in Australian early childhood education and care settings. By juxtaposing digital images produced by two different digital-camera technologies and drawing on…

  2. Mars Science Laboratory Engineering Cameras

    NASA Technical Reports Server (NTRS)

    Maki, Justin N.; Thiessen, David L.; Pourangi, Ali M.; Kobzeff, Peter A.; Lee, Steven W.; Dingizian, Arsham; Schwochert, Mark A.

    2012-01-01

    NASA's Mars Science Laboratory (MSL) Rover, which launched to Mars in 2011, is equipped with a set of 12 engineering cameras. These cameras are build-to-print copies of the Mars Exploration Rover (MER) cameras, which were sent to Mars in 2003. The engineering cameras weigh less than 300 grams each and use less than 3 W of power. Images returned from the engineering cameras are used to navigate the rover on the Martian surface, deploy the rover robotic arm, and ingest samples into the rover sample processing system. The navigation cameras (Navcams) are mounted to a pan/tilt mast and have a 45-degree square field of view (FOV) with a pixel scale of 0.82 mrad/pixel. The hazard avoidance cameras (Haz - cams) are body-mounted to the rover chassis in the front and rear of the vehicle and have a 124-degree square FOV with a pixel scale of 2.1 mrad/pixel. All of the cameras utilize a frame-transfer CCD (charge-coupled device) with a 1024x1024 imaging region and red/near IR bandpass filters centered at 650 nm. The MSL engineering cameras are grouped into two sets of six: one set of cameras is connected to rover computer A and the other set is connected to rover computer B. The MSL rover carries 8 Hazcams and 4 Navcams.

  3. The Panoramic Camera (PanCam) Instrument for the ESA ExoMars Rover

    NASA Astrophysics Data System (ADS)

    Griffiths, A.; Coates, A.; Jaumann, R.; Michaelis, H.; Paar, G.; Barnes, D.; Josset, J.

    The recently approved ExoMars rover is the first element of the ESA Aurora programme and is slated to deliver the Pasteur exobiology payload to Mars by 2013. The 0.7 kg Panoramic Camera will provide multispectral stereo images with 65° field-of- view (1.1 mrad/pixel) and high resolution (85 µrad/pixel) monoscopic "zoom" images with 5° field-of-view. The stereo Wide Angle Cameras (WAC) are based on Beagle 2 Stereo Camera System heritage. The Panoramic Camera instrument is designed to fulfil the digital terrain mapping requirements of the mission as well as providing multispectral geological imaging, colour and stereo panoramic images, solar images for water vapour abundance and dust optical depth measurements and to observe retrieved subsurface samples before ingestion into the rest of the Pasteur payload. Additionally the High Resolution Camera (HRC) can be used for high resolution imaging of interesting targets detected in the WAC panoramas and of inaccessible locations on crater or valley walls.

  4. Intercomparison of phenological transition dates derived from the PhenoCam Dataset V1.0 and MODIS satellite remote sensing.

    PubMed

    Richardson, Andrew D; Hufkens, Koen; Milliman, Tom; Frolking, Steve

    2018-04-09

    Phenology is a valuable diagnostic of ecosystem health, and has applications to environmental monitoring and management. Here, we conduct an intercomparison analysis using phenological transition dates derived from near-surface PhenoCam imagery and MODIS satellite remote sensing. We used approximately 600 site-years of data, from 128 camera sites covering a wide range of vegetation types and climate zones. During both "greenness rising" and "greenness falling" transition phases, we found generally good agreement between PhenoCam and MODIS transition dates for agricultural, deciduous forest, and grassland sites, provided that the vegetation in the camera field of view was representative of the broader landscape. The correlation between PhenoCam and MODIS transition dates was poor for evergreen forest sites. We discuss potential reasons (including sub-pixel spatial heterogeneity, flexibility of the transition date extraction method, vegetation index sensitivity in evergreen systems, and PhenoCam geolocation uncertainty) for varying agreement between time series of vegetation indices derived from PhenoCam and MODIS imagery. This analysis increases our confidence in the ability of satellite remote sensing to accurately characterize seasonal dynamics in a range of ecosystems, and provides a basis for interpreting those dynamics in the context of tangible phenological changes occurring on the ground.

  5. A novel calibration method of focused light field camera for 3-D reconstruction of flame temperature

    NASA Astrophysics Data System (ADS)

    Sun, Jun; Hossain, Md. Moinul; Xu, Chuan-Long; Zhang, Biao; Wang, Shi-Min

    2017-05-01

    This paper presents a novel geometric calibration method for focused light field camera to trace the rays of flame radiance and to reconstruct the three-dimensional (3-D) temperature distribution of a flame. A calibration model is developed to calculate the corner points and their projections of the focused light field camera. The characteristics of matching main lens and microlens f-numbers are used as an additional constrains for the calibration. Geometric parameters of the focused light field camera are then achieved using Levenberg-Marquardt algorithm. Total focused images in which all the points are in focus, are utilized to validate the proposed calibration method. Calibration results are presented and discussed in details. The maximum mean relative error of the calibration is found less than 0.13%, indicating that the proposed method is capable of calibrating the focused light field camera successfully. The parameters obtained by the calibration are then utilized to trace the rays of flame radiance. A least square QR-factorization algorithm with Plank's radiation law is used to reconstruct the 3-D temperature distribution of a flame. Experiments were carried out on an ethylene air fired combustion test rig to reconstruct the temperature distribution of flames. The flame temperature obtained by the proposed method is then compared with that obtained by using high-precision thermocouple. The difference between the two measurements was found no greater than 6.7%. Experimental results demonstrated that the proposed calibration method and the applied measurement technique perform well in the reconstruction of the flame temperature.

  6. Using the VentCam and Optical Plume Velocimetry to Measure High-Temperature Hydrothermal Fluid Flow Rates in the ASHES Vent Field on Axial Volcano

    NASA Astrophysics Data System (ADS)

    Crone, T. J.; Mittelstaedt, E. L.; Fornari, D. J.

    2014-12-01

    Fluid flow rates through high-temperature mid-ocean ridge hydrothermal vents are likely quite sensitive to poroelastic forcing mechanisms such as tidal loading and tectonic activity. Because poroelastic deformation and flow perturbations are estimated to extend to considerable depths within young oceanic crust, observations of flow rate changes at seafloor vents have the potential to provide constraints on the flow geometry and permeability structure of the underlying hydrothermal systems, as well as the quantities of heat and chemicals they exchange with overlying ocean, and the potential biological productivity of ecosystems they host. To help provide flow rate measurements in these challenging environments, we have developed two new optical flow oriented technologies. The first is a new form of Optical Plume Velocimetry (OPV) which relies on single-frame temporal cross-correlation to obtain time-averaged image velocity fields from short video sequences. The second is the VentCam, a deep sea camera system that can collect high-frame-rate video sequences at focused hydrothermal vents suitable for analysis with OPV. During the July 2014 R/V Atlantis/Alvin expedition to Axial Seamount, we deployed the VentCam at the ~300C Phoenix vent within the ASHES vent field and positioned it with DSRV Alvin. We collected 24 seconds of video at 50 frames per second every half-hour for approximately 10 days beginning July 22nd. We are currently applying single-frame lag OPV to these videos to estimate relative and absolute fluid flow rates through this vent. To explore the relationship between focused and diffuse venting, we deployed a second optical flow camera, the Diffuse Effluent Measurement System (DEMS), adjacent to this vent at a fracture within the lava carapace where low-T (~30C) fluids were exiting. This system collected video sequences and diffuse flow measurements at overlapping time intervals. Here we present the preliminary results of our work with VentCam and OPV

  7. The path to CAM6: coupled simulations with CAM5.4 and CAM5.5

    NASA Astrophysics Data System (ADS)

    Bogenschutz, Peter A.; Gettelman, Andrew; Hannay, Cecile; Larson, Vincent E.; Neale, Richard B.; Craig, Cheryl; Chen, Chih-Chieh

    2018-01-01

    This paper documents coupled simulations of two developmental versions of the Community Atmosphere Model (CAM) towards CAM6. The configuration called CAM5.4 introduces new microphysics, aerosol, and ice nucleation changes, among others to CAM. The CAM5.5 configuration represents a more radical departure, as it uses an assumed probability density function (PDF)-based unified cloud parameterization to replace the turbulence, shallow convection, and warm cloud macrophysics in CAM. This assumed PDF method has been widely used in the last decade in atmosphere-only climate simulations but has never been documented in coupled mode. Here, we compare the simulated coupled climates of CAM5.4 and CAM5.5 and compare them to the control coupled simulation produced by CAM5.3. We find that CAM5.5 has lower cloud forcing biases when compared to the control simulations. Improvements are also seen in the simulated amplitude of the Niño-3.4 index, an improved representation of the diurnal cycle of precipitation, subtropical surface wind stresses, and double Intertropical Convergence Zone biases. Degradations are seen in Amazon precipitation as well as slightly colder sea surface temperatures and thinner Arctic sea ice. Simulation of the 20th century results in a credible simulation that ends slightly colder than the control coupled simulation. The authors find this is due to aerosol indirect effects that are slightly stronger in the new version of the model and propose a solution to ameliorate this. Overall, in these early coupled simulations, CAM5.5 produces a credible climate that is appropriate for science applications and is ready for integration into the National Center for Atmospheric Research's (NCAR's) next-generation climate model.

  8. Alkali trace elements in Gale crater, Mars, with ChemCam: Calibration update and geological implications

    NASA Astrophysics Data System (ADS)

    Payré, V.; Fabre, C.; Cousin, A.; Sautter, V.; Wiens, R. C.; Forni, O.; Gasnault, O.; Mangold, N.; Meslin, P.-Y.; Lasue, J.; Ollila, A.; Rapin, W.; Maurice, S.; Nachon, M.; Le Deit, L.; Lanza, N.; Clegg, S.

    2017-03-01

    The Chemistry Camera (ChemCam) instrument onboard Curiosity can detect minor and trace elements such as lithium, strontium, rubidium, and barium. Their abundances can provide some insights about Mars' magmatic history and sedimentary processes. We focus on developing new quantitative models for these elements by using a new laboratory database (more than 400 samples) that displays diverse compositions that are more relevant for Gale crater than the previous ChemCam database. These models are based on univariate calibration curves. For each element, the best model is selected depending on the results obtained by using the ChemCam calibration targets onboard Curiosity. New quantifications of Li, Sr, Rb, and Ba in Gale samples have been obtained for the first 1000 Martian days. Comparing these data in alkaline and magnesian rocks with the felsic and mafic clasts from the Martian meteorite NWA7533—from approximately the same geologic period—we observe a similar behavior: Sr, Rb, and Ba are more concentrated in soluble- and incompatible-element-rich mineral phases (Si, Al, and alkali-rich). Correlations between these trace elements and potassium in materials analyzed by ChemCam reveal a strong affinity with K-bearing phases such as feldspars, K-phyllosilicates, and potentially micas in igneous and sedimentary rocks. However, lithium is found in comparable abundances in alkali-rich and magnesium-rich Gale rocks. This very soluble element can be associated with both alkali and Mg-Fe phases such as pyroxene and feldspar. These observations of Li, Sr, Rb, and Ba mineralogical associations highlight their substitution with potassium and their incompatibility in magmatic melts.

  9. Marginal and internal fit of CAD-CAM-fabricated composite resin and ceramic crowns scanned by 2 intraoral cameras.

    PubMed

    de Paula Silveira, Alessandra C; Chaves, Sacha B; Hilgert, Leandro A; Ribeiro, Ana Paula D

    2017-03-01

    The precision of fit of chairside computer-aided design and computer-aided manufacturing (CAD-CAM) complete crowns is affected by digital impression and restorative material. The purpose of this in vitro study was to evaluate by microcomputed tomography (μCT) the marginal and internal adaptation of composite resin and ceramic complete crowns fabricated with 2 different intraoral cameras and 2 restorative materials. Ten extracted human third molars received crown preparations. For each prepared molar, 2 digital impressions were made with different intraoral cameras of the CEREC system, Bluecam and Omnicam. Four groups were formed: LB (Lava Ultimate+Bluecam), EB (Emax+Bluecam), LO (Lava Ultimate+Omnicam), and EO (Emax+Omnicam). Before measuring the precision of fit, all crowns were stabilized with a silicone material. Each unit (crown + prepared tooth) was imaged with μCT, and marginal and internal discrepancies were analyzed. For the 2D analysis, 120 measurements were made of each crown for marginal adaptation, 20 for marginal discrepancy (MD), and 20 for absolute marginal discrepancy (AMD); and for internal adaptation, 40 for axial space (AS) and 40 for occlusal space (OS). After reconstructing the 3D images, the average internal space (AIS) was calculated by dividing the total volume of the internal space by the contact surface. Data were analyzed with 2-way ANOVA and quantile regression. Regarding marginal adaptation, no significant differences were observed among groups. For internal adaptation measured in the 2D evaluation, a significant difference was observed between LO and EO for the AS variable (Mann-Whitney test; P<.008). In assessment of AIS by the 3D reconstruction, LB presented significantly lower values than the other groups (Tukey post hoc test; P<.05). Bluecam presented lower values of AIS than Omnicam, and composite resin crowns showed less discrepancy than did ceramic crowns. The marginal adaptations assessed in all groups showed values within

  10. Dental calculus detection using the VistaCam.

    PubMed

    Shakibaie, Fardad; Walsh, Laurence J

    2016-12-01

    The VistaCam® intra-oral camera system (Dürr Dental, Bietigheim-Bissingen, Germany) is a fluorescence system using light emitting diodes that produce a 405-nm violet light. This wavelength has potential application for detection of dental calculus based on red emissions from porphyrin molecules. This study assessed the digital scores obtained for both supragingival and subgingival calculus on 60 extracted teeth and compared these with lesions of dental caries. It has also examined the effect of saliva and blood on the fluorescence readings for dental calculus. VistaCam fluorescence scores for both supragingival (1.7-3.3) and subgingival calculus (1.3-2.4) were higher than those for sound root surfaces (0.9-1.1) and dental caries (0.9-2.2) ( p  < .05). The readings for calculus samples were not affected by the presence of saliva or blood. These results suggest that the use of violet light fluorescence could be a possible adjunct to clinical examination for deposits of dental calculus.

  11. Laser-Induced Fluorescence Emission (L.I.F.E.): searching for Mars organics with a UV-enhanced PanCam.

    PubMed

    Storrie-Lombardi, Michael C; Muller, Jan-Peter; Fisk, Martin R; Cousins, Claire; Sattler, Birgit; Griffiths, Andrew D; Coates, Andrew J

    2009-12-01

    The European Space Agency will launch the ExoMars mission in 2016 with a primary goal of surveying the martian subsurface for evidence of organic material. We have recently investigated the utility of including either a 365 nm light-emitting diode or a 375 nm laser light source in the ExoMars rover panoramic camera (PanCam). Such a modification would make it feasible to monitor rover drill cuttings optically for the fluorescence signatures of aromatic organic molecules and map the distribution of polycyclic aromatic hydrocarbons (PAHs) as a function of depth to the 2 m limit of the ExoMars drill. The technique described requires no sample preparation, does not consume irreplaceable resources, and would allow mission control to prioritize deployment of organic detection experiments that require sample destruction, expenditure of non-replaceable consumables, or both. We report here for the first time laser-induced fluorescence emission (L.I.F.E.) imaging detection limits for anthracene, pyrene, and perylene targets doped onto a Mars analog granular peridotite with a 375 nm Nichia laser diode in optically uncorrected wide-angle mode. Data were collected via the Beagle 2 PanCam backup filter wheel fitted with original blue (440 nm), green (530 nm), and red (670 nm) filters. All three PAH species can be detected with the PanCam green (530 nm) filter. Detection limits in the green band for signal-to-noise ratios (S/N) > 10 are 49 parts per million (ppm) for anthracene, 145 ppm for pyrene, and 20 ppm for perylene. The anthracene detection limit improves to 7 ppm with use of the PanCam blue filter. We discuss soil-dependent detection limit constraints; use of UV excitation with other rover cameras, which provides higher spatial resolution; and the advantages of focused and wide-angle laser modes. Finally, we discuss application of L.I.F.E. techniques at multiple wavelengths for exploration of Mars analog extreme environments on Earth, including Icelandic hydrothermally

  12. SenseCam improves memory for recent events and quality of life in a patient with memory retrieval difficulties.

    PubMed

    Browne, Georgina; Berry, Emma; Kapur, Narinder; Hodges, Steve; Smyth, Gavin; Watson, Peter; Wood, Ken

    2011-10-01

    A wearable camera that takes pictures automatically, SenseCam, was used to generate images for rehearsal, promoting consolidation and retrieval of memories for significant events in a patient with memory retrieval deficits. SenseCam images of recent events were systematically reviewed over a 2-week period. Memory for these events was assessed throughout and longer-term recall was tested up to 6 months later. A written diary control condition followed the same procedure. The SenseCam review procedure resulted in significantly more details of an event being recalled, with twice as many details recalled at 6 months follow up compared to the written diary method. Self-report measures suggested autobiographical recollection was triggered by the SenseCam condition but not by reviewing the written diary. Emotional and social wellbeing questionnaires indicated improved confidence and decreased anxiety as a result of memory rehearsal using SenseCam images. We propose that SenseCam images provide a powerful boost to autobiographical recall, with secondary benefits for quality of life.

  13. Complementary and alternative medicine (CAM) among hospitalised patients: reported use of CAM and reasons for use, CAM preferred during hospitalisation, and the socio-demographic determinants of CAM users.

    PubMed

    Shorofi, Seyed Afshin

    2011-11-01

    This paper reports a study to examine hospitalised patients' frequency and patterns of CAM use, their reasons for CAM use, their preferences of CAMs during hospitalisation, and the association between patients' socio-demographic variables and use of each individual CAM/CAM domain. A convenience sample of 353 patients hospitalised in 19 surgical wards at four metropolitan hospitals completed a questionnaire on CAM use and socio-demographic variables. The response rate was 73.5%, and over 90% of the sample acknowledged using CAMs. Non-herbal supplements (60.3%) and massage therapy (45%) were the most frequently used CAMs, with biologically based therapies (68.8%) as well as mind-body interventions (65.4%) being the most often used CAM domains. About 1 in 10 patients (9.6%) used CAMs from all five domains. With the exception of herbal-botanical therapies, self-prayer for health reasons/spiritual healing and music therapy, all CAMs were mainly used on an 'only when needed' basis. The most common reason nominated for using CAMs was that '[it] fits into my way of life/philosophy' (26%). The majority of patients declared interest in and support for the hospital providing CAMs. Patients were most inclined to choose therapies categorised as manipulative and body-based methods (65.4%) for use in hospital. Massage therapy (53.5%) and non-herbal supplements (43.1%) were the top two CAMs favoured for use in hospital. CAM use was also dependent of socio-demographic data (age, gender, marital status, place of residence, education level, religion, and income in hospitalised patients). The use of CAMs is pervasive amongst surgical in-patients, making it feasible to initially assess these patients for CAM use and provide them with clinically approved CAMs where possible. Notwithstanding that CAM use is fairly predictable by socio-demographic variables, further studies should be directed to know the variables useful for predicting the use of each CAM approach. Copyright © 2011

  14. Volume phase holographic gratings for the Subaru Prime Focus Spectrograph: performance measurements of the prototype grating set

    NASA Astrophysics Data System (ADS)

    Barkhouser, Robert H.; Arns, James; Gunn, James E.

    2014-08-01

    The Prime Focus Spectrograph (PFS) is a major instrument under development for the 8.2 m Subaru telescope on Mauna Kea. Four identical, fixed spectrograph modules are located in a room above one Nasmyth focus. A 55 m fiber optic cable feeds light into the spectrographs from a robotic fiber positioner mounted at the telescope prime focus, behind the wide field corrector developed for Hyper Suprime-Cam. The positioner contains 2400 fibers and covers a 1.3 degree hexagonal field of view. Each spectrograph module will be capable of simultaneously acquiring 600 spectra. The spectrograph optical design consists of a Schmidt collimator, two dichroic beamsplitters to separate the light into three channels, and for each channel a volume phase holographic (VPH) grating and a dual- corrector, modified Schmidt reimaging camera. This design provides a 275 mm collimated beam diameter, wide simultaneous wavelength coverage from 380 nm to 1.26 µm, and good imaging performance at the fast f/1.1 focal ratio required from the cameras to avoid oversampling the fibers. The three channels are designated as the blue, red, and near-infrared (NIR), and cover the bandpasses 380-650 nm (blue), 630-970 nm (red), and 0.94-1.26 µm (NIR). A mosaic of two Hamamatsu 2k×4k, 15 µm pixel CCDs records the spectra in the blue and red channels, while the NIR channel employs a 4k×4k, substrate-removed HAWAII-4RG array from Teledyne, with 15 µm pixels and a 1.7 µm wavelength cutoff. VPH gratings have become the dispersing element of choice for moderate-resolution astronomical spectro- graphs due their potential for very high diffraction efficiency, low scattered light, and the more compact instru- ment designs offered by transmissive dispersers. High quality VPH gratings are now routinely being produced in the sizes required for instruments on large telescopes. These factors made VPH gratings an obvious choice for PFS. In order to reduce risk to the project, as well as fully exploit the performance

  15. Measuring and modelling ecosystem productivity: a PhenoCam-based approach.

    NASA Astrophysics Data System (ADS)

    Hufkens, K.; Keenan, T. F.; Flanagan, L. B.; Richardson, A. D.

    2015-12-01

    Phenology controls feedbacks to the climate system through abiotic and biotic forces such as albedo or fluxes of water, energy and CO2. Understanding and modelling these vegetation-climate feedbacks is key to accurately predicting a future climate. For the past 6 years the PhenoCam network, a network of near-surface remote sensing cameras, has consistently monitored vegetation phenology in a wide range of ecoregions, climate zones, and plant functional types. Here we explore the tight coupling between canopy greenness and rates of photosynthesis using two studies. A first study highlights how PhenoCam data can be used to quantify the effect of a late spring frost event on ecosystem productivity, introducing a 7-14% loss in annual gross productivity across 8753 km2 in the northeastern United States. This case study emphasizes the use of the PhenoCam data in estimating productivity loss / the opportunity cost of ecosystem disturbance in areas not covered by ecosystem flux measurement equipment. In a more recent, second, study we developed a PhenoCam data-informed pulse-response model of grassland growth to explore potential responses of grasslands to future climate change across North America. Our findings projected widespread and consistent increase in grassland productivity (for the current range of grassland ecosystems of North American) over the coming century, despite a general increase in aridity projected across most of our study area. Once more PhenoCam data allowed us to inform our modelling efforts with data of a high temporal and spatial resolution. In conclusion, both studies illustrate direct applications of the ever growing PhenoCam network (http://phenocam.sr.unh.edu/webcam/) in scaling the effects of ecosystem disturbances, predicting future ecosystem productivity and underscore the complementary nature of PhenoCam data with ecosystem exchange measurements.

  16. JunoCam's Images of Jupiter

    NASA Astrophysics Data System (ADS)

    Hansen, C. J.; Ravine, M. A.; Caplinger, M. A.; Orton, G. S.; Ingersoll, A. P.; Jensen, E.; Lipkaman, L.; Krysak, D.; Zimdar, R.; Bolton, S. J.

    2016-12-01

    JunoCam is a visible imager on the Juno spacecraft in orbit around Jupiter. It is a wide angle camera (58 deg field of view) with 4 color filters: red, green and blue (RGB) and methane at 889 nm, designed for optimal imaging of Jupiter's poles. Juno's elliptical polar orbit will offer unique views of Jupiter's polar regions with a spatial scale of 50 km/pixel. At closest approach the images will have a spatial scale of 3 km/pixel. As a push-frame imager on a rotating spacecraft, JunoCam uses time-delayed integration to take advantage of the spacecraft spin to extend integration time to increase signal. Images of Jupiter's poles reveal a largely uncharted region of Jupiter, as nearly all earlier spacecraft have orbited or flown by in the equatorial plane. Most of the images of Jupiter will be acquired in the +/-2 hours surrounding closest approach. The polar vortex, polar cloud morphology, and winds will be investigated. RGB color images of the aurora will be acquired if detectable. Stereo images and images taken with the methane filter will allow us to estimate cloud-top heights. Images of the cloud-tops will aid in understanding the data collected by other instruments on Juno that probe deeper in the atmosphere. During the two months that Jupiter is too close to the sun for ground-based observers to collect data, JunoCam will take images routinely to monitor large-scale features. Occasional, opportunistic images of the Galilean moons will be acquired.

  17. Integrating CAM into nursing curricula: CAM camp as an educational intervention.

    PubMed

    Cornman, B Jane; Carr, Catherine A; Heitkemper, Margaret M

    2006-05-01

    In 2002, the University of Washington School of Nursing (SON) partnered with Bastyr University on a five-year plan to offer a four-week intensive "CAM Camp" (CAMp) for SON faculty members and medical students from across the country. The four-week educational program introduced attendees to various complementary and alternative medicine (CAM) modalities through didactic and experiential learning. To enhance complementary and alternative medicine content in a SON curriculum and to increase SON faculty knowledge and understanding about (1) the range of CAM therapies, (2) the theoretic and cultural backgrounds of these therapies, and (3) their potential contributions to the health of diverse populations. A descriptive pretest, posttest design was used to compare pre-CAMp CAM knowledge and CAM course content with post-CAMp knowledge levels of faculty and course CAM content. On post-CAMp surveys, familiarity with CAM modalities was rated with mixed results as compared with positive reports on the qualitative interviews. Interview results were more positive about CAM in general and were less specific about individual CAM topics. Statistically significant increases in competences were evident in each of 13 competencies rated with four competencies at P < .01. The number of required and elective courses containing CAM content increased as did the CAM content in continuing education conferences offered by the SON.

  18. Is prayer CAM?

    PubMed

    Tippens, Kim; Marsman, Kevin; Zwickey, Heather

    2009-04-01

    Alternative medicine researchers and policy makers have classified prayer as a mind-body intervention, and thus, a modality of complementary and alternative medicine (CAM). As such, numerous epidemiological surveys of CAM utilization-which have included prayer-depict increasing CAM use, particularly in specific racial and ethnic groups. This paper discusses the implications of conflating prayer and CAM, especially regarding the definitions of both concepts and the resulting statistics of CAM utilization.

  19. Three dimensional measurement with an electrically tunable focused plenoptic camera

    NASA Astrophysics Data System (ADS)

    Lei, Yu; Tong, Qing; Xin, Zhaowei; Wei, Dong; Zhang, Xinyu; Liao, Jing; Wang, Haiwei; Xie, Changsheng

    2017-03-01

    A liquid crystal microlens array (LCMLA) with an arrayed microhole pattern electrode based on nematic liquid crystal materials using a fabrication method including traditional UV-photolithography and wet etching is presented. Its focusing performance is measured under different voltage signals applied between the electrodes of the LCMLA. The experimental outcome shows that the focal length of the LCMLA can be tuned easily by only changing the root mean square value of the voltage signal applied. The developed LCMLA is further integrated with a main lens and an imaging sensor to construct a LCMLA-based focused plenoptic camera (LCFPC) prototype. The focused range of the LCFPC can be shifted electrically along the optical axis of the imaging system. The principles and methods for acquiring several key parameters such as three dimensional (3D) depth, positioning, and motion expression are given. The depth resolution is discussed in detail. Experiments are carried out to obtain the static and dynamic 3D information of objects chosen.

  20. Three dimensional measurement with an electrically tunable focused plenoptic camera.

    PubMed

    Lei, Yu; Tong, Qing; Xin, Zhaowei; Wei, Dong; Zhang, Xinyu; Liao, Jing; Wang, Haiwei; Xie, Changsheng

    2017-03-01

    A liquid crystal microlens array (LCMLA) with an arrayed microhole pattern electrode based on nematic liquid crystal materials using a fabrication method including traditional UV-photolithography and wet etching is presented. Its focusing performance is measured under different voltage signals applied between the electrodes of the LCMLA. The experimental outcome shows that the focal length of the LCMLA can be tuned easily by only changing the root mean square value of the voltage signal applied. The developed LCMLA is further integrated with a main lens and an imaging sensor to construct a LCMLA-based focused plenoptic camera (LCFPC) prototype. The focused range of the LCFPC can be shifted electrically along the optical axis of the imaging system. The principles and methods for acquiring several key parameters such as three dimensional (3D) depth, positioning, and motion expression are given. The depth resolution is discussed in detail. Experiments are carried out to obtain the static and dynamic 3D information of objects chosen.

  1. Alkali trace elements in Gale crater, Mars, with ChemCam: Calibration update and geological implications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Payre, Valerie; Fabre, Cecile; Cousin, Agnes

    The Chemistry Camera (ChemCam) instrument onboard Curiosity can detect minor and trace elements such as lithium, strontium, rubidium, and barium. Their abundances can provide some insights about Mars' magmatic history and sedimentary processes. We focus on developing new quantitative models for these elements by using a new laboratory database (more than 400 samples) that displays diverse compositions that are more relevant for Gale crater than the previous ChemCam database. These models are based on univariate calibration curves. For each element, the best model is selected depending on the results obtained by using the ChemCam calibration targets onboard Curiosity. New quantificationsmore » of Li, Sr, Rb, and Ba in Gale samples have been obtained for the first 1000 Martian days. Comparing these data in alkaline and magnesian rocks with the felsic and mafic clasts from the Martian meteorite NWA7533—from approximately the same geologic period—we observe a similar behavior: Sr, Rb, and Ba are more concentrated in soluble- and incompatible-element-rich mineral phases (Si, Al, and alkali-rich). Correlations between these trace elements and potassium in materials analyzed by ChemCam reveal a strong affinity with K-bearing phases such as feldspars, K-phyllosilicates, and potentially micas in igneous and sedimentary rocks. However, lithium is found in comparable abundances in alkali-rich and magnesium-rich Gale rocks. This very soluble element can be associated with both alkali and Mg-Fe phases such as pyroxene and feldspar. Here, these observations of Li, Sr, Rb, and Ba mineralogical associations highlight their substitution with potassium and their incompatibility in magmatic melts.« less

  2. Alkali trace elements in Gale crater, Mars, with ChemCam: Calibration update and geological implications

    DOE PAGES

    Payre, Valerie; Fabre, Cecile; Cousin, Agnes; ...

    2017-03-20

    The Chemistry Camera (ChemCam) instrument onboard Curiosity can detect minor and trace elements such as lithium, strontium, rubidium, and barium. Their abundances can provide some insights about Mars' magmatic history and sedimentary processes. We focus on developing new quantitative models for these elements by using a new laboratory database (more than 400 samples) that displays diverse compositions that are more relevant for Gale crater than the previous ChemCam database. These models are based on univariate calibration curves. For each element, the best model is selected depending on the results obtained by using the ChemCam calibration targets onboard Curiosity. New quantificationsmore » of Li, Sr, Rb, and Ba in Gale samples have been obtained for the first 1000 Martian days. Comparing these data in alkaline and magnesian rocks with the felsic and mafic clasts from the Martian meteorite NWA7533—from approximately the same geologic period—we observe a similar behavior: Sr, Rb, and Ba are more concentrated in soluble- and incompatible-element-rich mineral phases (Si, Al, and alkali-rich). Correlations between these trace elements and potassium in materials analyzed by ChemCam reveal a strong affinity with K-bearing phases such as feldspars, K-phyllosilicates, and potentially micas in igneous and sedimentary rocks. However, lithium is found in comparable abundances in alkali-rich and magnesium-rich Gale rocks. This very soluble element can be associated with both alkali and Mg-Fe phases such as pyroxene and feldspar. Here, these observations of Li, Sr, Rb, and Ba mineralogical associations highlight their substitution with potassium and their incompatibility in magmatic melts.« less

  3. Buying CAM.

    ERIC Educational Resources Information Center

    Meloy, Jim; And Others

    1990-01-01

    The relationship between computer-aided design (CAD), computer-aided manufacturing (CAM), and computer numerical control (CNC) computer applications is described. Tips for helping educate the CAM buyer on what to look for and what to avoid when searching for the most appropriate instructional CAM package are provided. (KR)

  4. Resin-composite blocks for dental CAD/CAM applications.

    PubMed

    Ruse, N D; Sadoun, M J

    2014-12-01

    Advances in digital impression technology and manufacturing processes have led to a dramatic paradigm shift in dentistry and to the widespread use of computer-aided design/computer-aided manufacturing (CAD/CAM) in the fabrication of indirect dental restorations. Research and development in materials suitable for CAD/CAM applications are currently the most active field in dental materials. Two classes of materials are used in the production of CAD/CAM restorations: glass-ceramics/ceramics and resin composites. While glass-ceramics/ceramics have overall superior mechanical and esthetic properties, resin-composite materials may offer significant advantages related to their machinability and intra-oral reparability. This review summarizes recent developments in resin-composite materials for CAD/CAM applications, focusing on both commercial and experimental materials. © International & American Associations for Dental Research.

  5. A challenge to identify an optical counterpart of the gravitational wave event GW151226 with Hyper Suprime-Cam†

    NASA Astrophysics Data System (ADS)

    Utsumi, Yousuke; Tominaga, Nozomu; Tanaka, Masaomi; Morokuma, Tomoki; Yoshida, Michitoshi; Asakura, Yuichiro; Finet, François; Furusawa, Hisanori; Kawabata, Koji S.; Liu, Wei; Matsubayashi, Kazuya; Moritani, Yuki; Motohara, Kentaro; Nakata, Fumiaki; Ohta, Kouji; Terai, Tsuyoshi; Uemura, Makoto; Yasuda, Naoki

    2018-01-01

    We present the results of detailed analysis of an optical imaging survey conducted using the Subaru/Hyper Suprime-Cam (HSC) that aimed to identify an optical counterpart to the gravitational wave event GW151226. In half a night, the i- and z-band imaging survey by HSC covered 63.5 deg2 of the error region, which contains about 7% of the LIGO localization probability, and the same field was observed in three different epochs. The detectable magnitude of the candidates in a differenced image is evaluated as i ˜ 23.2 mag for the requirement of at least two 5 σ detections, and 1744 candidates are discovered. Assuming a kilonova as an optical counterpart, we compare the optical properties of the candidates with model predictions. A red and rapidly declining light curve condition enables the discrimination of a kilonova from other transients, and a small number of candidates satisfy this condition. The presence of stellar-like counterparts in the reference frame suggests that the surviving candidates are likely to be flare stars. The fact that most of those candidates are in the galactic plane, |b| < 5°, supports this interpretation. We also check whether the candidates are associated with the nearby GLADE galaxies, which reduces the number of contaminants even with a looser color cut. When a better probability map (with localization accuracy of ˜50 deg2) is available, kilonova searches of up to approximately 200 Mpc will become feasible by conducting immediate follow-up observations with an interval of 3-6 d.

  6. Is Prayer CAM?

    PubMed Central

    Marsman, Kevin; Zwickey, Heather

    2009-01-01

    Abstract Background Alternative medicine researchers and policy makers have classified prayer as a mind–body intervention, and thus, a modality of complementary and alternative medicine (CAM). As such, numerous epidemiological surveys of CAM utilization—which have included prayer—depict increasing CAM use, particularly in specific racial and ethnic groups. Objectives This paper discusses the implications of conflating prayer and CAM, especially regarding the definitions of both concepts and the resulting statistics of CAM utilization. PMID:19388867

  7. NASA's "Webb-cam" Captures Engineers at Work on Webb at Johnson Space Center

    NASA Image and Video Library

    2017-05-30

    Now that NASA's James Webb Space Telescope has moved to NASA's Johnson Space Center in Houston, Texas, a special Webb camera was installed there to continue providing daily video feeds on the telescope's progress. Space enthusiasts, who are fascinated to see how this next generation space telescope has come together and how it is being tested, are able to see the telescope’s progress as it happens by watching the Webb-cam feed online. The Web camera at NASA’s Johnson Space Center can be seen online at: jwst.nasa.gov/, with larger views of the cams available at: jwst.nasa.gov/webcam.html. Read more: go.nasa.gov/2rQYpT2 NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram

  8. CAMS confirmation of previously reported meteor showers

    NASA Astrophysics Data System (ADS)

    Jenniskens, P.; Nénon, Q.; Gural, P. S.; Albers, J.; Haberman, B.; Johnson, B.; Holman, D.; Morales, R.; Grigsby, B. J.; Samuels, D.; Johannink, C.

    2016-03-01

    Leading up to the 2015 IAU General Assembly, the International Astronomical Union's Working List of Meteor Showers included 486 unconfirmed showers, showers that are not certain to exist. If confirmed, each shower would provide a record of past comet or asteroid activity. Now, we report that 41 of these are detected in the Cameras for Allsky Meteor Surveillance (CAMS) video-based meteor shower survey. They manifest as meteoroids arriving at Earth from a similar direction and orbit, after removing the daily radiant drift due to Earth's motion around the Sun. These showers do exist and, therefore, can be moved to the IAU List of Established Meteor Showers. This adds to 31 previously confirmed showers from CAMS data. For each shower, finding charts are presented based on 230,000 meteors observed up to March of 2015, calculated by re-projecting the drift-corrected Sun-centered ecliptic coordinates into more familiar equatorial coordinates. Showers that are not detected, but should have, and duplicate showers that project to the same Sun-centered ecliptic coordinates, are recommended for removal from the Working List.

  9. Retinal axial focusing and multi-layer imaging with a liquid crystal adaptive optics camera

    NASA Astrophysics Data System (ADS)

    Liu, Rui-Xue; Zheng, Xian-Liang; Li, Da-Yu; Xia, Ming-Liang; Hu, Li-Fa; Cao, Zhao-Liang; Mu, Quan-Quan; Xuan, Li

    2014-09-01

    With the help of adaptive optics (AO) technology, cellular level imaging of living human retina can be achieved. Aiming to reduce distressing feelings and to avoid potential drug induced diseases, we attempted to image retina with dilated pupil and froze accommodation without drugs. An optimized liquid crystal adaptive optics camera was adopted for retinal imaging. A novel eye stared system was used for stimulating accommodation and fixating imaging area. Illumination sources and imaging camera kept linkage for focusing and imaging different layers. Four subjects with diverse degree of myopia were imaged. Based on the optical properties of the human eye, the eye stared system reduced the defocus to less than the typical ocular depth of focus. In this way, the illumination light can be projected on certain retina layer precisely. Since that the defocus had been compensated by the eye stared system, the adopted 512 × 512 liquid crystal spatial light modulator (LC-SLM) corrector provided the crucial spatial fidelity to fully compensate high-order aberrations. The Strehl ratio of a subject with -8 diopter myopia was improved to 0.78, which was nearly close to diffraction-limited imaging. By finely adjusting the axial displacement of illumination sources and imaging camera, cone photoreceptors, blood vessels and nerve fiber layer were clearly imaged successfully.

  10. Cryogenic Cam Butterfly Valve

    NASA Technical Reports Server (NTRS)

    McCormack, Kenneth J. (Inventor)

    2016-01-01

    A cryogenic cam butterfly valve has a body that includes an axially extending fluid conduit formed there through. A disc lug is connected to a back side of a valve disc and has a circular bore that receives and is larger than a cam of a cam shaft. The valve disc is rotatable for a quarter turn within the body about a lug axis that is offset from the shaft axis. Actuating the cam shaft in the closing rotational direction first causes the camming side of the cam of the cam shaft to rotate the disc lug and the valve disc a quarter turn from the open position to the closed position. Further actuating causes the camming side of the cam shaft to translate the valve disc into sealed contact with the valve seat. Opening rotational direction of the cam shaft reverses these motions.

  11. Explosive Transient Camera (ETC) Program

    DTIC Science & Technology

    1991-10-01

    VOLTAGES 4.- VIDEO OUT CCD CLOCKING UNIT UUPSTAIRS" ELECTRONICS AND ANALOG TO DIGITAL IPR OCECSSER I COMMANDS TO DATA AND STATUS INSTRUMENT INFORMATION I...and transmits digital video and status information to the "downstairs" system. The clocking unit and regulator/driver board are the only CCD dependent...A. 1001, " Video Cam-era’CC’" tandari Piells" (1(P’ll m-norartlum, unpublished). Condon,, J.J., Puckpan, M.A., and Vachalski, J. 1970, A. J., 9U, 1149

  12. Integrated ExoMars PanCam, Raman, and close-up imaging field tests on AMASE 2009

    NASA Astrophysics Data System (ADS)

    Foss Amundsen, Hans Erik; Westall, Frances; Steele, Andrew; Vago, Jorge; Schmitz, Nicole; Bauer, Arnold; Cousins, Claire; Rull, Fernando; Sansano, Antonio; Midtkandal, Ivar

    2010-05-01

    Arctic Mars Analog Svalbard Expedition (AMASE) uses Mars analog field sites on the Arctic islands of Svalbard (Norway) for research within astrobiology and for testing of payload instruments onboard Mars missions Mars Science Laboratory, ExoMars and Mars Sample Return. AMASE 2009 marked the seventh consecutive year of field testing. Instrument shakedowns were arranged to mimic rover operations on Mars and included the panoramic camera (PanCam), mineral- and organic chemistry sensors (Raman-LIBS) and ground penetrating radar (Wisdom) onboard ExoMars together with CheMin and SAM instruments onboard MSL and testing of sampling and caching protocols using JPĹs Fido rover. Test sites included volcanic rocks within the Bockfjord Volcanic Complex (BVC) with carbonate deposits identical to those in ALH84001 and Carboniferous sandstones and paleosols at Ismåsestranda. In view of the 2018 ExoMars mission, field models of the PanCam and Raman instruments, as well as an Olympus E410 camera having similar technical specifications to the ExoMars Close-Up Imager (CLUPI) were used in an integrated exercise to characterise the geology and habitability of the different field sites. The BVC locality consisted of volcanclastic sediments deposited on the flanks of the 1 Ma old Sverrefjell volcano. This volcano is constructed of primitive alkaline basalt with abundant mantle xenoliths. The sediments were a mixture of hyaloclastite, ash, volcanic bombs, lava detritus, and xenoliths (peridotites, granulites) deposited in a roughly laminated fashion on the slopes of the volcano. Late stage carbonate deposits were also present. The Ismåsestranda locality consisted of fine-grained sandstone deposited in a littoral environment. The sandstones were characterised by a variety of sedimentary structures reflecting a marginal marine depositional environment. They were highly variegated in colour due to diagenetic remobilisation of trace elements. PanCam made general context observations using

  13. NGEE Arctic Zero Power Warming PhenoCamera Images, Barrow, Alaska, 2016

    DOE Data Explorer

    Shawn Serbin; Andrew McMahon; Keith Lewin; Kim Ely; Alistair Rogers

    2016-11-14

    StarDot NetCam SC pheno camera images collected from the top of the Barrow, BEO Sled Shed. The camera was installed to monitor the BNL TEST group's prototype ZPW (Zero Power Warming) chambers during the growing season of 2016 (including early spring and late fall). Images were uploaded to the BNL FTP server every 10 minutes and renamed with the date and time of the image. See associated data "Zero Power Warming (ZPW) Chamber Prototype Measurements, Barrow, Alaska, 2016" http://dx.doi.org/10.5440/1343066.

  14. L1-CAM and N-CAM: From Adhesion Proteins to Pharmacological Targets.

    PubMed

    Colombo, Federico; Meldolesi, Jacopo

    2015-11-01

    L1 cell adhesion molecule (L1-CAM) and neural cell adhesion molecule (N-CAM), key members of the immunoglobulin-like CAM (Ig-CAM) family, were first recognized to play critical roles in surface interactions of neurons, by binding with each other and with extracellular matrix (ECM) proteins. Subsequently, adhesion was recognized to include signaling due to both activation of β-integrin, with the generation of intracellular cascades, and integration with the surface cytoskeleton. The importance of the two Ig-CAMs was revealed by their activation of the tyrosine kinase receptors of fibroblast growth factor (FGF), epidermal growth factor (EGF), and nerve growth factor (NGF). Based on these complex signaling properties, L1-CAM and N-CAM have become of great potential pharmacological interest in neurons and cancers. Treatment of neurodegenerative disorders and cognitive deficits of neurons is aimed to increase the cell Ig-CAM tone, possibly provided by synthetic/mimetic peptides. In cancer cells, where Ig-CAMs are often overexpressed, the proteins are employed for prognosis. The approaches to therapy are based on protein downregulation, antibodies, and adoptive immunotherapy. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Quantifying external focus of attention in sailing by means of action sport cameras.

    PubMed

    Pluijms, Joost P; Cañal-Bruland, Rouwen; Hoozemans, Marco J M; Van Beek, Morris W; Böcker, Kaj; Savelsbergh, Geert J P

    2016-08-01

    The aim of the current study was twofold: (1) to validate the use of action sport cameras for quantifying focus of visual attention in sailing and (2) to apply this method to examine whether an external focus of attention is associated with better performance in upwind sailing. To test the validity of this novel quantification method, we first calculated the agreement between gaze location measures and head orientation measures in 13 sailors sailing upwind during training regattas using a head mounted eye tracker. The results confirmed that for measuring visual focus of attention in upwind sailing, the agreement for the two measures was high (intraclass correlation coefficient (ICC) = 0.97) and the 95% limits of agreement were acceptable (between -8.0% and 14.6%). In a next step, we quantified the focus of visual attention in sailing upwind as fast as possible by means of an action sport camera. We captured sailing performance, operationalised as boat speed in the direction of the wind, and environmental conditions using a GPS, compass and wind meter. Four trials, each lasting 1 min, were analysed for 15 sailors each, resulting in a total of 30 upwind speed trials on port tack and 30 upwind speed trials on starboard tack. The results revealed that in sailing - within constantly changing environments - the focus of attention is not a significant predictor for better upwind sailing performances. This implicates that neither external nor internal foci of attention was per se correlated with better performances. Rather, relatively large interindividual differences seem to indicate that different visual attention strategies can lead to similar performance outcomes.

  16. VizieR Online Data Catalog: Subaru-UDGs in the Coma cluster (Yagi+, 2016)

    NASA Astrophysics Data System (ADS)

    Yagi, M.; Koda, J.; Komiyama, Y.; Yamanoi, H.

    2016-10-01

    We retrieved a wide W-C-RC band (R-band) survey of the Coma cluster of Suprime-Cam from the Subaru public archive (SMOKA; Baba et al. 2002ASPC..281..298B) between 2011 Mar 02 and 2011 Apr 01. (1 data file).

  17. JunoCam's Imaging of Jupiter

    NASA Astrophysics Data System (ADS)

    Orton, Glenn; Hansen, Candice; Momary, Thomas; Caplinger, Michael; Ravine, Michael; Atreya, Sushil; Ingersoll, Andrew; Bolton, Scott; Rogers, John; Eichstaedt, Gerald

    2017-04-01

    Juno's visible imager, JunoCam, is a wide-angle camera (58° field of view) with 4 color filters: red, green and blue (RGB) and methane at 889 nm, designed for optimal imaging of Jupiter's poles. Juno's elliptical polar orbit offers unique views of Jupiter's polar regions with spatial scales as good as 50 km/pixel. At closest approach ("perijove") the images have spatial scale down to ˜3 km/pixel. As a push-frame imager on a rotating spacecraft, JunoCam uses time-delayed integration to take advantage of the spacecraft spin to extend integration time to increase signal. Images of Jupiter's poles reveal a largely uncharted region of Jupiter, as nearly all earlier spacecraft except Pioneer 11 have orbited or flown by close to the equatorial plane. Poleward of 64-68° planetocentric latitude, Jupiter's familiar east-west banded structure breaks down. Several types of discrete features appear on a darker, bluish-cast background. Clusters of circular cyclonic spirals are found immediately around the north and south poles. Oval-shaped features are also present, ranging in size down to JunoCam's resolution limits. The largest and brightest features usually have chaotic shapes; animations over ˜1 hour can reveal cyclonic motion in them. Narrow linear features traverse tens of degrees of longitude and are not confined in latitude. JunoCam also detected optically thin clouds or hazes that are illuminated beyond the nightside ˜1-bar terminator; one of these detected at Perijove lay some 3 scale heights above the main cloud deck. Tests have been made to detect the aurora and lightning. Most close-up images of Jupiter have been acquired at lower latitudes within 2 hours of closest approach. These images aid in understanding the data collected by other instruments on Juno that probe deeper in the atmosphere. When Jupiter was too close to the sun for ground-based observers to collect data between perijoves 1 and 2, JunoCam took a sequence of routine images to monitor large

  18. The ChemCam Instrument Suite on the Mars Science Laboratory (MSL) Rover: Science Objectives and Mast Unit Description

    USGS Publications Warehouse

    Maurice, S.; Wiens, R.C.; Saccoccio, M.; Barraclough, B.; Gasnault, O.; Forni, O.; Mangold, N.; Baratoux, D.; Bender, S.; Berger, G.; Bernardin, J.; Berthé, M.; Bridges, N.; Blaney, D.; Bouyé, M.; Caïs, P.; Clark, B.; Clegg, S.; Cousin, A.; Cremers, D.; Cros, A.; DeFlores, L.; Derycke, C.; Dingler, B.; Dromart, G.; Dubois, B.; Dupieux, M.; Durand, E.; d'Uston, L.; Fabre, C.; Faure, B.; Gaboriaud, A.; Gharsa, T.; Herkenhoff, K.; Kan, E.; Kirkland, L.; Kouach, D.; Lacour, J.-L.; Langevin, Y.; Lasue, J.; Le Mouélic, S.; Lescure, M.; Lewin, E.; Limonadi, D.; Manhès, G.; Mauchien, P.; McKay, C.; Meslin, P.-Y.; Michel, Y.; Miller, E.; Newsom, Horton E.; Orttner, G.; Paillet, A.; Parès, L.; Parot, Y.; Pérez, R.; Pinet, P.; Poitrasson, F.; Quertier, B.; Sallé, B.; Sotin, Christophe; Sautter, V.; Séran, H.; Simmonds, J.J.; Sirven, J.-B.; Stiglich, R.; Striebig, N.; Thocaven, J.-J.; Toplis, M.J.; Vaniman, D.

    2012-01-01

    ChemCam is a remote sensing instrument suite on board the "Curiosity" rover (NASA) that uses Laser-Induced Breakdown Spectroscopy (LIBS) to provide the elemental composition of soils and rocks at the surface of Mars from a distance of 1.3 to 7 m, and a telescopic imager to return high resolution context and micro-images at distances greater than 1.16 m. We describe five analytical capabilities: rock classification, quantitative composition, depth profiling, context imaging, and passive spectroscopy. They serve as a toolbox to address most of the science questions at Gale crater. ChemCam consists of a Mast-Unit (laser, telescope, camera, and electronics) and a Body-Unit (spectrometers, digital processing unit, and optical demultiplexer), which are connected by an optical fiber and an electrical interface. We then report on the development, integration, and testing of the Mast-Unit, and summarize some key characteristics of ChemCam. This confirmed that nominal or better than nominal performances were achieved for critical parameters, in particular power density (>1 GW/cm2). The analysis spot diameter varies from 350 μm at 2 m to 550 μm at 7 m distance. For remote imaging, the camera field of view is 20 mrad for 1024×1024 pixels. Field tests demonstrated that the resolution (˜90 μrad) made it possible to identify laser shots on a wide variety of images. This is sufficient for visualizing laser shot pits and textures of rocks and soils. An auto-exposure capability optimizes the dynamical range of the images. Dedicated hardware and software focus the telescope, with precision that is appropriate for the LIBS and imaging depths-of-field. The light emitted by the plasma is collected and sent to the Body-Unit via a 6 m optical fiber. The companion to this paper (Wiens et al. this issue) reports on the development of the Body-Unit, on the analysis of the emitted light, and on the good match between instrument performance and science specifications.

  19. CAMS newly detected meteor showers and the sporadic background

    NASA Astrophysics Data System (ADS)

    Jenniskens, P.; Nénon, Q.; Gural, P. S.; Albers, J.; Haberman, B.; Johnson, B.; Morales, R.; Grigsby, B. J.; Samuels, D.; Johannink, C.

    2016-03-01

    The Cameras for Allsky Meteor Surveillance (CAMS) video-based meteoroid orbit survey adds 60 newly identified showers to the IAU Working List of Meteor Showers (numbers 427, 445-446, 506-507, and part of 643-750). 28 of these are also detected in the independent SonotaCo survey. In total, 230 meteor showers and shower components are identified in CAMS data, 177 of which are detected in at least two independent surveys. From the power-law size frequency distribution of detected showers, we extrapolate that 36% of all CAMS-observed meteors originated from ∼700 showers above the N = 1 per 110,000 shower limit. 71% of mass falling to Earth from streams arrives on Jupiter-family type orbits. The transient Geminids account for another 15%. All meteoroids not assigned to streams form a sporadic background with highest detected numbers from the apex source, but with 98% of mass falling in from the antihelion source. Even at large ∼7-mm sizes, a Poynting-Robertson drag evolved population is detected, which implies that the Grün et al. collisional lifetimes at these sizes are underestimated by about a factor of 10. While these large grains survive collisions, many fade on a 104-y timescale, possibly because they disintegrate into smaller particles by processes other than collisions, leaving a more resilient population to evolve.

  20. L1CAM: amending the "low-risk" category in endometrial carcinoma.

    PubMed

    Kommoss, Felix; Kommoss, Friedrich; Grevenkamp, Friederike; Bunz, Anne-Kathrin; Taran, Florin-Andrei; Fend, Falko; Brucker, Sara Y; Wallwiener, Diethelm; Schönfisch, Birgitt; Greif, Karen; Lax, Sigurd; Staebler, Annette; Kommoss, Stefan

    2017-02-01

    Low- and intermediate-risk endometrial carcinomas have an excellent prognosis. Nonetheless, a small subgroup of such patients will experience unexpected relapse. Recently L1CAM was suggested to be a strong prognosticator in endometrial carcinoma. The focus of our study was on low- and intermediate-risk disease, where no or only limited adjuvant treatment is recommended according to current guidelines. Endometrial carcinomas of low, intermediate and high-intermediate risk according to published 2016 consensus guidelines were identified. The study was limited to cases with previous central pathology review focusing on histotype, depth of myometrial invasion, presence of lymphovascular space invasion (LVSI) and MELF pattern of invasion. Standard L1CAM immunohistochemistry was performed. Disease-specific uni- and multivariate survival analyses were calculated. A total of 344 cases were available for immunohistochemistry (low-risk: n = 250; intermediate-risk: n = 67; high-intermediate-risk: n = 27). L1CAM positivity rates were: 29/344 (8.4 %; all cases), 18/250 (7.2 %; low-risk), 6/67 (9.0 %; intermediate-risk) and 5/27 (18.5 %; high-intermediate-risk). Expression of L1CAM was independent of LVSI and MELF. L1CAM was a significant independent prognosticator for disease-specific survival with a hazard ratio of 5.98 [CI 1.50-22.14, p = 0.012]. Adverse prognostic significance of L1CAM positivity was maintained after low-risk subgroup analysis (5-year disease-specific survival rates 71.8 vs. 100 %, p < 0.0001). All four tumour-related deaths in the subgroup of low-risk disease occurred in patients with L1CAM-positive tumours. The current definition of "low-risk" in endometrial carcinoma should be amended. "Low-risk carcinomas" should be limited to L1CAM-negative tumours. L1CAM status will play a key role in future algorithms to tailor adjuvant treatment and patient follow-up strategies.

  1. The use of low cost compact cameras with focus stacking functionality in entomological digitization projects

    PubMed Central

    Mertens, Jan E.J.; Roie, Martijn Van; Merckx, Jonas; Dekoninck, Wouter

    2017-01-01

    Abstract Digitization of specimen collections has become a key priority of many natural history museums. The camera systems built for this purpose are expensive, providing a barrier in institutes with limited funding, and therefore hampering progress. An assessment is made on whether a low cost compact camera with image stacking functionality can help expedite the digitization process in large museums or provide smaller institutes and amateur entomologists with the means to digitize their collections. Images of a professional setup were compared with the Olympus Stylus TG-4 Tough, a low-cost compact camera with internal focus stacking functions. Parameters considered include image quality, digitization speed, price, and ease-of-use. The compact camera’s image quality, although inferior to the professional setup, is exceptional considering its fourfold lower price point. Producing the image slices in the compact camera is a matter of seconds and when optimal image quality is less of a priority, the internal stacking function omits the need for dedicated stacking software altogether, further decreasing the cost and speeding up the process. In general, it is found that, aware of its limitations, this compact camera is capable of digitizing entomological collections with sufficient quality. As technology advances, more institutes and amateur entomologists will be able to easily and affordably catalogue their specimens. PMID:29134038

  2. Advancements in CAD/CAM technology: Options for practical implementation.

    PubMed

    Alghazzawi, Tariq F

    2016-04-01

    The purpose of this review is to present a comprehensive review of the current published literature investigating the various methods and techniques for scanning, designing, and fabrication of CAD/CAM generated restorations along with detailing the new classifications of CAD/CAM technology. I performed a review of a PubMed using the following search terms "CAD/CAM, 3D printing, scanner, digital impression, and zirconia". The articles were screened for further relevant investigations. The search was limited to articles written in English, published from 2001 to 2015. In addition, a manual search was also conducted through articles and reference lists retrieved from the electronic search and peer-reviewed journals. CAD/CAM technology has advantages including digital impressions and models, and use of virtual articulators. However, the implementation of this technology is still considered expensive and requires highly trained personnel. Currently, the design software has more applications including complete dentures and removable partial denture frameworks. The accuracy of restoration fabrication can be best attained with 5 axes milling units. The 3D printing technology has been incorporated into dentistry, but does not include ceramics and is limited to polymers. In the future, optical impressions will be replaced with ultrasound impressions using ultrasonic waves, which have the capability to penetrate the gingiva non-invasively without retraction cords and not be affected by fluids. The coming trend for most practitioners will be the use of an acquisition camera attached to a computer with the appropriate software and the capability of forwarding the image to the laboratory. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  3. External combustion engine having an asymmetrical CAM

    NASA Astrophysics Data System (ADS)

    Duva, Anthony W.

    1994-11-01

    An external combustion engine having an asymmetrical cam is the focus of this patent. The engine includes a combustion chamber for generating a high-pressure, energized gas from a monopropellant fuel and an even number of cylinders for receiving sequentially the energized gas through the rotary valve, the gas performing work on a piston disposed within each cylinder. The pistons transfer energy to a drive shaft through a connection to the asymmetrically shaped cam. The cam is shaped having two identical halves, each half having a power and an exhaust stroke. The identical halves provide that opposing cylinders are in thermodynamic balance, thus reducing rocking vibrations and torque pulsations. Having opposing pistons within the same thermodynamic cycle allows piston stroke to be reduced while maintaining displacement comparable to an engine having individual cycle positions. The reduced stroke diminishes gas flow velocity thus reducing flow induced noise. The power and exhaust strokes within each identical half of the cam are asymmetrical in that the power stroke is of greater duration than the exhaust stroke. The shape and length of the power stroke is optimized for increased efficiency.

  4. Impact of SenseCam on memory, identity and mood in Korsakoff's syndrome: a single case experimental design study.

    PubMed

    Svanberg, Jenny; Evans, Jonathan J

    2014-01-01

    This study aimed to investigate the impact of SenseCam, a wearable, automatic camera, on subjective mood and identity in a patient with severe memory impairment due to Korsakoff's syndrome. It was hypothesised that SenseCam would improve Ms A's mood and identity through enhancing recall of autobiographical memories of recent events, therefore supporting a coherent sense of self; the lack of which was contributing to Ms A's mood deterioration. An ABA single case experimental design investigated whether using SenseCam to record regular activities impacted on Ms A's mood and identity. Ms A experienced improved recall for events recorded using SenseCam, and showed improvement on subjective ratings of identity. However, a corresponding improvement in mood was not seen, and the study was ended early at Ms A's request. Qualitative information was gathered to explore Ms A's experience of the study, and investigate psychosocial factors that may have impacted on the use of SenseCam. SenseCam may be of significant use as a compensatory memory aid for people with Korsakoff's syndrome and other types of alcohol-related brain damage (ARBD), but acceptance of memory impairment and consistent support may be among the factors required to support the use of such assistive technologies in a community setting.

  5. CAM/LIFTER forces and friction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gabbey, D.J.; Lee, J.; Patterson, D.J.

    1992-02-01

    This report details the procedures used to measure the cam/lifter forces and friction. The present effort employed a Cummins LTA-10, and focuses on measurements and dynamic modeling of the injector train. The program was sponsored by the US Department of Energy in support of advanced diesel engine technology. The injector train was instrumented to record the instantaneous roller speed, roller pin friction torque, pushrod force, injector link force and cam speed. These measurements, together with lift profiles for pushrod and injector link displacement, enabled the friction work loss in the injector train to be determined. Other significant design criteria suchmore » as camshaft roller follower slippage and maximum loads on components were also determined. Future efforts will concentrate on the dynamic model, with tests run as required for correlation.« less

  6. PillCam(TradeMark), a Noninvasive Endoscopic Device for the Measurement of Gastrointestinal Motility Changes

    NASA Technical Reports Server (NTRS)

    Vaksman, Zahman; Crady, Camille; Raju, G. S.; Putcha, Lakshmi

    2007-01-01

    Introduction: Bioavailability and effectiveness of drugs given by mouth are governed in part by gastrointestinal (GI) motility and function. Microgravity has been shown to decrease GI motility as indicated by a 3 fold increase in gastrointestinal transit time (GITT). The PillCam(TradeMark), an endoscopic camera embedded in a capsule, is a novel noninvasive and unobtrusive device that is used for the diagnosis of GI pathology. The purpose of this study is to evaluate the usefulness of PillCam(TradeMark) as an alternative to the Lactulose Breath Hydrogen Test (LBHT) for estimating GI motility. The sensitivity and applicability of this device for detection and estimation of the effect of promethazine, a deterrent, and caffeine, a prokinetic, on GI motility were also examined. Method: In this semi-randomized cross-over design study, six male and six female subjects were administered the following 4 treatments: PillCam(TradeMark) alone, PillCam(TradeMark)+Lactulose (10g), PillCam(TradeMark)+caffeine (200mg), and PillCam(TradeMark)+Promethazine (50mg). Results: GITT ranged between 1:24 and 7:52 hr:min. Lactulose did not alter GITT. A significant increase in GITT was noticed after administration of PMZ when compared to values from PillCam(TradeMark) treatment alone or PillCam(TradeMark)+Lactulose treatment. No difference in GITT after caffeine treatment was noticed. While there were no gender related differences in GITT after administration of PillCam(TradeMark) or with lactulose, a significant difference (p<.05) between genders was observed after promethazine administration with mean GITT higher in males (5:50 hr:min) than females (4:15 hr:min). Conclusion: The PillCam(TradeMark) capsule is applicable for the determination of GITT using time stamped GI images. It can be successfully used for the assessment of drug induced changes in GI motility and therefore, may be applicable for microgravity and analog environment studies on GI motility and function.

  7. Consequences of systematic model drift in DYNAMO MJO hindcasts with SP-CAM and CAM5

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hannah, Walter M.; Maloney, Eric D.; Pritchard, Michael S.

    Hindcast simulations of MJO events during the dynamics of the MJO (DYNAMO) field campaign are conducted with two models, one with conventional parameterization (CAM5) and a comparable model that utilizes superparameterization (SP–CAM). SP–CAM is shown to produce a qualitatively better reproduction of the fluctuations of precipitation and low–level zonal wind associated with the first two DYNAMO MJO events compared to CAM5. Interestingly, skill metrics using the real–time multivariate MJO index (RMM) suggest the opposite conclusion that CAM5 has more skill than SP–CAM. This inconsistency can be explained by a systematic increase of RMM amplitude with lead time, which results frommore » a drift of the large–scale wind field in SP–CAM that projects strongly onto the RMM index. CAM5 hindcasts exhibit a contraction of the moisture distribution, in which extreme wet and dry conditions become less frequent with lead time. SP–CAM hindcasts better reproduce the observed moisture distribution, but also have stronger drift patterns of moisture budget terms, such as an increase in drying by meridional advection in SP–CAM. This advection tendency in SP–CAM appears to be associated with enhanced off–equatorial synoptic eddy activity with lead time. In conclusion, systematic drift moisture tendencies in SP–CAM are of similar magnitude to intraseasonal moisture tendencies, and therefore are important for understanding MJO prediction skill.« less

  8. Subcellular distributions of rat CaM kinase phosphatase N and other members of the CaM kinase regulatory system.

    PubMed

    Kitani, Takako; Okuno, Sachiko; Takeuchi, Masayuki; Fujisawa, Hitoshi

    2003-07-01

    Ca2+/Calmodulin-dependent protein kinase (CaM kinase) regulatory system is composed of multifunctional CaM kinases such as CaM kinases IV and I, upstream CaM kinases such as CaM kinase kinases alpha and beta, which activate multifunctional CaM kinases, and CaM kinase phosphatases such as CaM kinase phosphatase and CaM kinase phosphatase N, which deactivate the activated multifunctional CaM kinases. To understand the combinations of CaM kinases I and IV, CaM kinase kinases alpha and beta, and CaM kinase phosphatases, the locations of the enzymes in the cell were examined by immunocytochemical studies of cultured cells. The results indicate that CaM kinase I, CaM kinase kinase beta, and CaM kinase phosphatase occur in the cytoplasm and that CaM kinase IV, CaM kinase kinase alpha (and CaM kinase kinase beta in some cell types and tissues), and CaM kinase phosphatase N occur inside the cellular nucleus, suggesting that there are at least two different sets of CaM kinase regulatory systems, one consisting of CaM kinase I, CaM kinase kinase beta, and CaM kinase phosphatase in the cytoplasm and the other consisting of CaM kinase IV, CaM kinase kinase alpha (and CaM kinase kinase beta in some cell types and tissues), and CaM kinase phosphatase N in the nucleus.

  9. A randomized comparison of laparoscopic, flexible endoscopic, and wired and wireless magnetic cameras on ex vivo and in vivo NOTES surgical performance.

    PubMed

    Chang, Victoria C; Tang, Shou-Jiang; Swain, C Paul; Bergs, Richard; Paramo, Juan; Hogg, Deborah C; Fernandez, Raul; Cadeddu, Jeffrey A; Scott, Daniel J

    2013-08-01

    The influence of endoscopic video camera (VC) image quality on surgical performance has not been studied. Flexible endoscopes are used as substitutes for laparoscopes in natural orifice translumenal endoscopic surgery (NOTES), but their optics are originally designed for intralumenal use. Manipulable wired or wireless independent VCs might offer advantages for NOTES but are still under development. To measure the optical characteristics of 4 VC systems and to compare their impact on the performance of surgical suturing tasks. VC systems included a laparoscope (Storz 10 mm), a flexible endoscope (Olympus GIF 160), and 2 prototype deployable cameras (magnetic anchoring and guidance system [MAGS] Camera and PillCam). In a randomized fashion, the 4 systems were evaluated regarding standardized optical characteristics and surgical manipulations of previously validated ex vivo (fundamentals of laparoscopic surgery model) and in vivo (live porcine Nissen model) tasks; objective metrics (time and errors/precision) and combined surgeon (n = 2) performance were recorded. Subtle differences were detected for color tests, and field of view was variable (65°-115°). Suitable resolution was detected up to 10 cm for the laparoscope and MAGS camera but only at closer distances for the endoscope and PillCam. Compared with the laparoscope, surgical suturing performances were modestly lower for the MAGS camera and significantly lower for the endoscope (ex vivo) and PillCam (ex vivo and in vivo). This study documented distinct differences in VC systems that may be used for NOTES in terms of both optical characteristics and surgical performance. Additional work is warranted to optimize cameras for NOTES. Deployable systems may be especially well suited for this purpose.

  10. Facultative crassulacean acid metabolism (CAM) plants: powerful tools for unravelling the functional elements of CAM photosynthesis.

    PubMed

    Winter, Klaus; Holtum, Joseph A M

    2014-07-01

    Facultative crassulacean acid metabolism (CAM) describes the optional use of CAM photosynthesis, typically under conditions of drought stress, in plants that otherwise employ C3 or C4 photosynthesis. In its cleanest form, the upregulation of CAM is fully reversible upon removal of stress. Reversibility distinguishes facultative CAM from ontogenetically programmed unidirectional C3-to-CAM shifts inherent in constitutive CAM plants. Using mainly measurements of 24h CO2 exchange, defining features of facultative CAM are highlighted in five terrestrial species, Clusia pratensis, Calandrinia polyandra, Mesembryanthemum crystallinum, Portulaca oleracea and Talinum triangulare. For these, we provide detailed chronologies of the shifts between photosynthetic modes and comment on their usefulness as experimental systems. Photosynthetic flexibility is also reviewed in an aquatic CAM plant, Isoetes howellii. Through comparisons of C3 and CAM states in facultative CAM species, many fundamental biochemical principles of the CAM pathway have been uncovered. Facultative CAM species will be of even greater relevance now that new sequencing technologies facilitate the mapping of genomes and tracking of the expression patterns of multiple genes. These technologies and facultative CAM systems, when joined, are expected to contribute in a major way towards our goal of understanding the essence of CAM. © The Author 2014. Published by Oxford University Press on behalf of the Society for Experimental Biology. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  11. Reconstruction of refocusing and all-in-focus images based on forward simulation model of plenoptic camera

    NASA Astrophysics Data System (ADS)

    Zhang, Rumin; Liu, Peng; Liu, Dijun; Su, Guobin

    2015-12-01

    In this paper, we establish a forward simulation model of plenoptic camera which is implemented by inserting a micro-lens array in a conventional camera. The simulation model is used to emulate how the space objects at different depths are imaged by the main lens then remapped by the micro-lens and finally captured on the 2D sensor. We can easily modify the parameters of the simulation model such as the focal lengths and diameters of the main lens and micro-lens and the number of micro-lens. Employing the spatial integration, the refocused images and all-in-focus images are rendered based on the plenoptic images produced by the model. The forward simulation model can be used to determine the trade-offs between different configurations and to test any new researches related to plenoptic camera without the need of prototype.

  12. Use of Complementary and Alternative Medicine (CAM) as Part of the Oncological Treatment: Survey about Patients' Attitude towards CAM in a University-Based Oncology Center in Germany.

    PubMed

    Kessel, Kerstin A; Lettner, Sabrina; Kessel, Carmen; Bier, Henning; Biedermann, Tilo; Friess, Helmut; Herrschbach, Peter; Gschwend, Jürgen E; Meyer, Bernhard; Peschel, Christian; Schmid, Roland; Schwaiger, Markus; Wolff, Klaus-Dietrich; Combs, Stephanie E

    2016-01-01

    To understand if and which patients would be open-minded to Complementary and Alternative Medicine (CAM) use parallel to their oncological treatment. Moreover, we sought to determine which methods are most accepted and which are the primary motivators to use CAM. We developed and anonymously conducted a questionnaire for patients in the oncology center (TU Munich). Questions focus on different CAM methods, previous experiences, and willingness to apply or use CAM when offered in a university-based setting. A total of 171 of 376 patients (37.4% women, 62.0% men, 0.6% unknown) participated. This corresponds to a return rate of 45%. Median age was 64 years (17-87 years). Of all participants, 15.2% used CAM during their oncological therapy; 32.7% have used it in the past. The majority (81.9%) was not using CAM during therapy; 55.5% have not used CAM in the past respectively. The analysis revealed a significant correlation between education and CAM use during therapy (r = 0.18; p = 0.02), and CAM use in the past (r = 0.17; p = 0.04). Of all patients using CAM during therapy, favored methods were food supplements (42.3%), vitamins/minerals (42.3%), massage (34.6%). Motivations are especially the reduction of side effect and stress, the positive effect of certain CAM-treatments on the immune system and tumor therapy. Results showed no difference between women and men. Most patients not having had any experience with CAM complain about the deficiency of information by their treating oncologist (31.4%) as well as missing treatment possibilities (54.3%). Since many patients believe in study results demonstrating the efficacy of CAM, it stresses our task to develop innovative study protocols to investigate the outcomes of certain CAM on symptom reduction or other endpoints. Thus, prospective trials and innovative evidence-based treatment concepts to include CAM into high-end oncology is what patients demand and what a modern oncology center should offer.

  13. Study of Permanent Magnet Focusing for Astronomical Camera Tubes

    NASA Technical Reports Server (NTRS)

    Long, D. C.; Lowrance, J. L.

    1975-01-01

    A design is developed of a permanent magnet assembly (PMA) useful as the magnetic focusing unit for the 35 and 70 mm (diagonal) format SEC tubes. Detailed PMA designs for both tubes are given, and all data on their magnetic configuration, size, weight, and structure of magnetic shields adequate to screen the camera tube from the earth's magnetic field are presented. A digital computer is used for the PMA design simulations, and the expected operational performance of the PMA is ascertained through the calculation of a series of photoelectron trajectories. A large volume where the magnetic field uniformity is greater than 0.5% appears obtainable, and the point spread function (PSF) and modulation transfer function(MTF) indicate nearly ideal performance. The MTF at 20 cycles per mm exceeds 90%. The weight and volume appear tractable for the large space telescope and ground based application.

  14. Sub-Camera Calibration of a Penta-Camera

    NASA Astrophysics Data System (ADS)

    Jacobsen, K.; Gerke, M.

    2016-03-01

    Penta cameras consisting of a nadir and four inclined cameras are becoming more and more popular, having the advantage of imaging also facades in built up areas from four directions. Such system cameras require a boresight calibration of the geometric relation of the cameras to each other, but also a calibration of the sub-cameras. Based on data sets of the ISPRS/EuroSDR benchmark for multi platform photogrammetry the inner orientation of the used IGI Penta DigiCAM has been analyzed. The required image coordinates of the blocks Dortmund and Zeche Zollern have been determined by Pix4Dmapper and have been independently adjusted and analyzed by program system BLUH. With 4.1 million image points in 314 images respectively 3.9 million image points in 248 images a dense matching was provided by Pix4Dmapper. With up to 19 respectively 29 images per object point the images are well connected, nevertheless the high number of images per object point are concentrated to the block centres while the inclined images outside the block centre are satisfying but not very strongly connected. This leads to very high values for the Student test (T-test) of the finally used additional parameters or in other words, additional parameters are highly significant. The estimated radial symmetric distortion of the nadir sub-camera corresponds to the laboratory calibration of IGI, but there are still radial symmetric distortions also for the inclined cameras with a size exceeding 5μm even if mentioned as negligible based on the laboratory calibration. Radial and tangential effects of the image corners are limited but still available. Remarkable angular affine systematic image errors can be seen especially in the block Zeche Zollern. Such deformations are unusual for digital matrix cameras, but it can be caused by the correlation between inner and exterior orientation if only parallel flight lines are used. With exception of the angular affinity the systematic image errors for corresponding

  15. In-flight photogrammetric camera calibration and validation via complementary lidar

    NASA Astrophysics Data System (ADS)

    Gneeniss, A. S.; Mills, J. P.; Miller, P. E.

    2015-02-01

    This research assumes lidar as a reference dataset against which in-flight camera system calibration and validation can be performed. The methodology utilises a robust least squares surface matching algorithm to align a dense network of photogrammetric points to the lidar reference surface, allowing for the automatic extraction of so-called lidar control points (LCPs). Adjustment of the photogrammetric data is then repeated using the extracted LCPs in a self-calibrating bundle adjustment with additional parameters. This methodology was tested using two different photogrammetric datasets, a Microsoft UltraCamX large format camera and an Applanix DSS322 medium format camera. Systematic sensitivity testing explored the influence of the number and weighting of LCPs. For both camera blocks it was found that when the number of control points increase, the accuracy improves regardless of point weighting. The calibration results were compared with those obtained using ground control points, with good agreement found between the two.

  16. Adaptive DOF for plenoptic cameras

    NASA Astrophysics Data System (ADS)

    Oberdörster, Alexander; Lensch, Hendrik P. A.

    2013-03-01

    Plenoptic cameras promise to provide arbitrary re-focusing through a scene after the capture. In practice, however, the refocusing range is limited by the depth of field (DOF) of the plenoptic camera. For the focused plenoptic camera, this range is given by the range of object distances for which the microimages are in focus. We propose a technique of recording light fields with an adaptive depth of focus. Between multiple exposures { or multiple recordings of the light field { the distance between the microlens array (MLA) and the image sensor is adjusted. The depth and quality of focus is chosen by changing the number of exposures and the spacing of the MLA movements. In contrast to traditional cameras, extending the DOF does not necessarily lead to an all-in-focus image. Instead, the refocus range is extended. There is full creative control about the focus depth; images with shallow or selective focus can be generated.

  17. Impact of IPAD on CAD/CAM database university research

    NASA Technical Reports Server (NTRS)

    Leach, L. M.; Wozny, M. J.

    1984-01-01

    IPAD program has provided direction, focus and software products which impacted on CAD/CAM data base research and follow-on research. The relationship of IPAD to the research projects which involve the storage of geometric data in common data ase facilities such as data base machines, the exchange of data between heterogeneous data bases, the development of IGES processors, the migration of lrge CAD/CAM data base management systems to noncompatible hosts, and the value of RIM as a research tool is described.

  18. A CNES remote operations center for the MSL ChemCam instrument

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wiens, Roger C; Lafaille, Vivian; Lorgny, Eric

    2010-01-01

    For the first time, a CNES remote operations center in Toulouse will be involved in the tactical operations of a Martian rover in order to operate the ChemCam science instrument in the framework of the NASA MSL (Mars Science Laboratory) mission in 2012. CNES/CESR and LANL have developed and delivered to JPL the ChemCam (Chemistry Camera) instrument located on the top of mast and in the body of the rover. This instrument incorporates a Laser-Induced Breakdown Spectrometer (LIBS) and a Remote Micro-Imager (RMI) for determining elemental compositions of rock targets or soil samples at remote distances from the rover (2-7more » m). An agreement has been achieved for operating ChemCam, alternatively, from Toulouse (FR) and Los Alamos (NM, USA), through the JPL ground data system in Pasadena (CA, USA) for a complete Martian year (2 years on Earth). After a brief overview of the MSL mission, this paper presents the instrument, the mission operational system and JPL organization requirements for the scientific investigators (PI and Co-Is). This paper emphasizes innovations applied on the ground segment components and on the operational approach to satisfy the requirements and constraints due to these shared and distributed operations over the world.« less

  19. Cam-Operated Pitch-Change Apparatus

    NASA Technical Reports Server (NTRS)

    Barnes, P. E. (Inventor)

    1978-01-01

    A pitch-change apparatus for a ducted thrust fan having a plurality of variable pitch blades employs a camming ring mounted coaxially at the hub at an axially fixed station along the hub axis for rotation about the hub axis both with the blades and relative to the blades. The ring has a generally spherical outer periphery and a plurality of helical camming grooves extending in a generally spherical plane on the periphery. Each of the variable pitch blades is connected to a pitch-change horn having a cam follower mounted on its outer end, and the camming ring and the horns are so arranged about the hub axis that the plurality of followers on the horns engage respectively the plurality of helical camming grooves. Rotary drive means rotates the camming ring relative to the blades to cause blade pitch to be changed through the cooperative operation of the camming grooves on the ring and the cam followers on the pitch-change horns.

  20. Preparing CAM-SE for Multi-Tracer Applications: CAM-SE-Cslam

    NASA Astrophysics Data System (ADS)

    Lauritzen, P. H.; Taylor, M.; Goldhaber, S.

    2014-12-01

    The NCAR-DOE spectral element (SE) dynamical core comes from the HOMME (High-Order Modeling Environment; Dennis et al., 2012) and it is available in CAM. The CAM-SE dynamical core is designed with intrinsic mimetic properties guaranteeing total energy conservation (to time-truncation errors) and mass-conservation, and has demonstrated excellent scalability on massively parallel compute platforms (Taylor, 2011). For applications involving many tracers such as chemistry and biochemistry modeling, CAM-SE has been found to be significantly more computationally costly than the current "workhorse" model CAM-FV (Finite-Volume; Lin 2004). Hence a multi-tracer efficient scheme, called the CSLAM (Conservative Semi-Lagrangian Multi-tracer; Lauritzen et al., 2011) scheme, has been implemented in the HOMME (Erath et al., 2012). The CSLAM scheme has recently been cast in flux-form in HOMME so that it can be coupled to the SE dynamical core through conventional flux-coupling methods where the SE dynamical core provides background air mass fluxes to CSLAM. Since the CSLAM scheme makes use of a finite-volume gnomonic cubed-sphere grid and hence does not operate on the SE quadrature grid, the capability of running tracer advection, the physical parameterization suite and dynamics on separate grids has been implemented in CAM-SE. The default CAM-SE-CSLAM setup is to run physics on the quasi-equal area CSLAM grid. The capability of running physics on a different grid than the SE dynamical core may provide a more consistent coupling since the physics grid option operates with quasi-equal-area cell average values rather than non-equi-distant grid-point (SE quadrature point) values. Preliminary results on the performance of CAM-SE-CSLAM will be presented.

  1. SuperCam_MastUnit

    NASA Astrophysics Data System (ADS)

    Deleuze, M. D.; Bernardi, P. B.; Caïs, Ph. C.; Perez, R. P.; Rees, J. M. R.; Pares, L. P.; Dubois, B. D.; Parot, Y. P.; Quertier, B. Q.; Maurice, S. M.; Maccabe, K. M.; Wiens, R. W.; Rull, F. R.

    2016-10-01

    This paper will describe and give a development status of SuperCam's mast unit. SuperCam will be carried on the Mars 2020 rover, and consists in an enhanced version of the ChemCam LIBS which is still performing at the surface of Mars, on Curiosity.

  2. The application of CAD / CAM technology in Dentistry

    NASA Astrophysics Data System (ADS)

    Susic, I.; Travar, M.; Susic, M.

    2017-05-01

    Information and communication technologies have found their application in the healthcare sector, including the frameworks of modern dentistry. CAD / CAM application in dentistry is the process by which is attained finished dental restoration through fine milling process of ready ceramic blocks. CAD / CAM is an acronym of english words Computer-Aided-Design (CAD) / Computer-Aided-Manufacture (CAM), respectively dental computer aided design and computer aided manufacture of inlays, onlays, crowns and bridges. CAD / CAM technology essentially allows you to create a two-dimensional and three-dimensional models and their materialization by numerical controlled machines. In order to operate more efficiently, reduce costs, increase user/patient satisfaction and ultimately achieve profits, many dental offices in the world have their attention focused on implementation of modern IT solutions in everyday practice. In addition to the specialized clinic management software, inventory control, etc., or hardware such as the use of lasers in cosmetic dentistry or intraoral scanning, recently the importance is given to the application of CAD / CAM technology in the field of prosthetic. After the removal of pathologically altered tooth structure, it is necessary to achieve restoration that will be most similar to the anatomy of a natural tooth. Applying CAD / CAM technology on applicable ceramic blocks it can be obtained very quick, but also very accurate restoration, in the forms of inlays, onlays, bridges and crowns. The paper presents the advantages of using this technology as well as satisfaction of the patients and dentists by using systems as: Cercon, Celay, Cerec, Lava, Everest, which represent imperative of modern dentistry in creating fixed dental restorations.

  3. Cam-controlled boring bar

    DOEpatents

    Glatthorn, Raymond H.

    1986-01-01

    A cam-controlled boring bar system (100) includes a first housing (152) which is rotatable about its longitudinal axis (154), and a second housing in the form of a cam-controlled slide (158) which is also rotatable about the axis (154) as well as being translatable therealong. A tool-holder (180) is mounted within the slide (158) for holding a single point cutting tool. Slide (158) has a rectangular configuration and is disposed within a rectangularly configured portion of the first housing (152). Arcuate cam slots (192) are defined within a side plate (172) of the housing (152), while cam followers (194) are mounted upon the cam slide (158) for cooperative engagement with the cam slots (192). In this manner, as the housing (152) and slide (158) rotate, and as the slide (158) also translates, a through-bore (14) having an hourglass configuration will be formed within a workpiece (16) which may be, for example, a nuclear reactor steam generator tube support plate.

  4. Real-time multiple objects tracking on Raspberry-Pi-based smart embedded camera

    NASA Astrophysics Data System (ADS)

    Dziri, Aziz; Duranton, Marc; Chapuis, Roland

    2016-07-01

    Multiple-object tracking constitutes a major step in several computer vision applications, such as surveillance, advanced driver assistance systems, and automatic traffic monitoring. Because of the number of cameras used to cover a large area, these applications are constrained by the cost of each node, the power consumption, the robustness of the tracking, the processing time, and the ease of deployment of the system. To meet these challenges, the use of low-power and low-cost embedded vision platforms to achieve reliable tracking becomes essential in networks of cameras. We propose a tracking pipeline that is designed for fixed smart cameras and which can handle occlusions between objects. We show that the proposed pipeline reaches real-time processing on a low-cost embedded smart camera composed of a Raspberry-Pi board and a RaspiCam camera. The tracking quality and the processing speed obtained with the proposed pipeline are evaluated on publicly available datasets and compared to the state-of-the-art methods.

  5. VARIABLE-THROW CAM

    DOEpatents

    Godsil, E.C.; Robinson, E.Y.

    1963-07-16

    A variable-throw cam comprising inner and outer eccentric sleeves which are adjustably locked together is described. The cam throw is varied by unlocking the inner and outer sleeves, rotating the outer sleeve relative to the inner one until the desired throw is obtained, and locking the sleeves together again. The cam is useful in applications wherein a continuously-variable throw is required, e.g., ram-and-die pressing operations, cyclic fatigue testing of materials, etc. (AEC)

  6. Quantitative analysis of digital outcrop data obtained from stereo-imagery using an emulator for the PanCam camera system for the ExoMars 2020 rover

    NASA Astrophysics Data System (ADS)

    Barnes, Robert; Gupta, Sanjeev; Gunn, Matt; Paar, Gerhard; Balme, Matt; Huber, Ben; Bauer, Arnold; Furya, Komyo; Caballo-Perucha, Maria del Pilar; Traxler, Chris; Hesina, Gerd; Ortner, Thomas; Banham, Steven; Harris, Jennifer; Muller, Jan-Peter; Tao, Yu

    2017-04-01

    A key focus of planetary rover missions is to use panoramic camera systems to image outcrops along rover traverses, in order to characterise their geology in search of ancient life. This data can be processed to create 3D point clouds of rock outcrops to be quantitatively analysed. The Mars Utah Rover Field Investigation (MURFI 2016) is a Mars Rover field analogue mission run by the UK Space Agency (UKSA) in collaboration with the Canadian Space Agency (CSA). It took place between 22nd October and 13th November 2016 and consisted of a science team based in Harwell, UK, and a field team including an instrumented Rover platform at the field site near Hanksville (Utah, USA). The Aberystwyth University PanCam Emulator 3 (AUPE3) camera system was used to collect stereo panoramas of the terrain the rover encountered during the field trials. Stereo-imagery processed in PRoViP is rendered as Ordered Point Clouds (OPCs) in PRo3D, enabling the user to zoom, rotate and translate the 3D outcrop model. Interpretations can be digitised directly onto the 3D surface, and simple measurements can be taken of the dimensions of the outcrop and sedimentary features, including grain size. Dip and strike of bedding planes, stratigraphic and sedimentological boundaries and fractures is calculated within PRo3D from mapped bedding contacts and fracture traces. Merging of rover-derived imagery with UAV and orbital datasets, to build semi-regional multi-resolution 3D models of the area of operations for immersive analysis and contextual understanding. In-simulation, AUPE3 was mounted onto the rover mast, collecting 16 stereo panoramas over 9 'sols'. 5 out-of-simulation datasets were collected in the Hanksville-Burpee Quarry. Stereo panoramas were processed using an automated pipeline and data transfer through an ftp server. PRo3D has been used for visualisation and analysis of this stereo data. Features of interest in the area could be annotated, and their distances between to the rover

  7. Complementary and alternative medicine (CAM) among Australian hospital-based nurses: knowledge, attitude, personal and professional use, reasons for use, CAM referrals, and socio-demographic predictors of CAM users.

    PubMed

    Shorofi, Seyed Afshin; Arbon, Paul

    2017-05-01

    This study was intended to examine CAM among Australian hospital-based nurses, identifying their knowledge, attitude, personal and professional use, reasons for use, CAM referrals, and socio-demographic predictors of CAM users. Nurses holding a qualification in nursing and working in surgical wards were included using a convenience sampling technique. A self-complete questionnaire was developed to achieve the aims of the study. Descriptive and non-parametric statistics were calculated to describe and analyse data. Overall, 95.7% and 49.7% of nurses reported personal and professional use of CAM, respectively. The most popular CAM/CAM domain personally and professionally used by nurses was massage therapy and mind-body therapies. The primary reason for personal use of CAM was "[it] fits into my way of life/philosophy". Furthermore, massage therapists were the most commonly recommended CAM practitioners to patients. Only 15.8% of nurses would always ask patients about use of herbal medicines as part of nursing history taking. Over one-fifth (22.4%) of nurses rated their attitude as having a very positive, and 60.3% rated themselves as having very little or no knowledge of CAM. A positive correlation was also found between knowledge and attitude about CAM. Positive attitude and higher knowledge about CAM were positively correlated to CAM referrals. Several socio-demographic factors predicted personal and professional use of CAM. This study revealed that nurses generally believe not to have sufficient knowledge of CAM but are open to use CAM with patients. Nurses' positive attitude toward and personal use of CAM could be an indication that they are poised for further integration of evidence-based CAM into nursing practice to treat whole person. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Helmet-Cam: tool for assessing miners’ respirable dust exposure

    PubMed Central

    Cecala, A.B.; Reed, W.R.; Joy, G.J.; Westmoreland, S.C.; O’Brien, A.D.

    2015-01-01

    Video technology coupled with datalogging exposure monitors have been used to evaluate worker exposure to different types of contaminants. However, previous application of this technology used a stationary video camera to record the worker’s activity while the worker wore some type of contaminant monitor. These techniques are not applicable to mobile workers in the mining industry because of their need to move around the operation while performing their duties. The Helmet-Cam is a recently developed exposure assessment tool that integrates a person-wearable video recorder with a datalogging dust monitor. These are worn by the miner in a backpack, safety belt or safety vest to identify areas or job tasks of elevated exposure. After a miner performs his or her job while wearing the unit, the video and dust exposure data files are downloaded to a computer and then merged together through a NIOSH-developed computer software program called Enhanced Video Analysis of Dust Exposure (EVADE). By providing synchronized playback of the merged video footage and dust exposure data, the EVADE software allows for the assessment and identification of key work areas and processes, as well as work tasks that significantly impact a worker’s personal respirable dust exposure. The Helmet-Cam technology has been tested at a number of metal/nonmetal mining operations and has proven to be a valuable assessment tool. Mining companies wishing to use this technique can purchase a commercially available video camera and an instantaneous dust monitor to obtain the necessary data, and the NIOSH-developed EVADE software will be available for download at no cost on the NIOSH website. PMID:26380529

  9. Quality of Life in CAM and Non-CAM Users among Breast Cancer Patients during Chemotherapy in Malaysia

    PubMed Central

    Chui, Ping Lei; Abdullah, Khatijah Lim; Wong, Li Ping; Taib, Nur Aishah

    2015-01-01

    Background Complementary and alternative medicine (CAM) use has become increasingly popular among patients with cancer. The purposes of this study were to compare the QOL in CAM users and non-CAM users and to determine whether CAM use influences QOL among breast cancer patients during chemotherapy. Methodology A cross-sectional survey was conducted at two outpatient chemotherapy centers. A total of 546 patients completed the questionnaires on CAM use. QOL was evaluated based on the European Organization for Research and Treatment of Cancer (EORTC) core quality of life (QLQ-C30) and breast cancer-specific quality of life (QLQ-BR23) questionnaires. Results A total of 70.7% of patients were identified as CAM users. There was no significant difference in global health status scores and in all five subscales of the QLQ C30 functional scales between CAM users and non-CAM users. On the QLQ-C30 symptom scales, CAM users (44.96±3.89) had significantly (p = 0.01) higher mean scores for financial difficulties than non-CAM users (36.29±4.81). On the QLQ-BR23 functional scales, CAM users reported significantly higher mean scores for sexual enjoyment (6.01±12.84 vs. 4.64±12.76, p = 0.04) than non-CAM users. On the QLQ-BR23 symptom scales, CAM users reported higher systemic therapy side effects (41.34±2.01 vs. 37.22±2.48, p = 0.04) and breast symptoms (15.76±2.13 vs. 11.08±2.62, p = 0.02) than non-CAM users. Multivariate logistic regression analysis indicated that the use of CAM modality was not significantly associated with higher global health status scores (p = 0.71). Conclusion While the findings indicated that there was no significant difference between users and non-users of CAM in terms of QOL, CAM may be used by health professionals as a surrogate to monitor patients with higher systemic therapy side effects and breast symptoms. Furthermore, given that CAM users reported higher financial burdens (which may have contributed to increased distress), patients should

  10. L1-CAM in cancerous tissues.

    PubMed

    Gavert, Nancy; Ben-Shmuel, Amir; Raveh, Shani; Ben-Ze'ev, Avri

    2008-11-01

    L1-cell adhesion molecule (L1-CAM) is a cell adhesion receptor of the immunoglobulin superfamily, known for its roles in nerve cell function. While originally believed to be present only in brain cells, in recent years L1-CAM has been detected in other tissues, and in a variety of cancer cells, including some common types of human cancer. We review the prevalence of L1-CAM in human cancer, the possible mechanisms involved in L1-CAM-mediated tumorigenesis, and cancer therapies based upon L1-CAM antibody treatment. In colon cancer cells, the L1-CAM gene was identified as a target of the Wnt/beta-catenin-TCF signaling pathway, and L1-CAM was exclusively detected at the invasive front of colon and ovarian cancer tissue. The expression of L1-CAM in normal and cancer cells enhanced tumorigenesis and conferred metastasis in colon cancer cells. Antibodies against the L1-CAM ectodomain severely inhibited the proliferation of a variety of cancer cells in culture and reduced tumor burden when injected into mice harboring cancer cells expressing L1-CAM. These results, in addition to the presence of L1-CAM on the cell surface and its restricted distribution in normal tissues, make it an ideal target for tumor therapy.

  11. Exploration of use of SenseCam to support autobiographical memory retrieval within a cognitive-behavioural therapeutic intervention following acquired brain injury.

    PubMed

    Brindley, Rob; Bateman, Andrew; Gracey, Fergus

    2011-10-01

    Delivering effective psychotherapy to address the significant emotional consequences of acquired brain injury (ABI) is challenged by the presence of acquired cognitive impairments, especially retrieval of detailed autobiographical memories of emotional trigger events. Initial studies using a wearable camera (SenseCam) suggest long-term improvements in autobiographical retrieval of recorded events. In this study a single-case experimental design was implemented to explore the use of SenseCam as a memory aid for a man with a specific anxiety disorder and memory and executive difficulties following ABI. We predicted that SenseCam supported rehearsal of memories of events that trigger high levels of anxiety would yield improved retrieval of both factual detail and internal state information (thoughts and feelings) compared with a conventional psychotherapy aid (automatic thought record sheets, ATRs) and no strategy. The findings indicated SenseCam supported retrieval of anxiety trigger events was superior to ATRs or no strategy in terms of both detail and internal state information, with 94% of the information being recalled in the SenseCam condition, compared to 39% for the "no strategy" and 22% for the ATR conditions. It is concluded that SenseCam may be of use as a compensatory aid in psychotherapies relying on retrieval of emotionally salient trigger events.

  12. The multifocus plenoptic camera

    NASA Astrophysics Data System (ADS)

    Georgiev, Todor; Lumsdaine, Andrew

    2012-01-01

    The focused plenoptic camera is based on the Lippmann sensor: an array of microlenses focused on the pixels of a conventional image sensor. This device samples the radiance, or plenoptic function, as an array of cameras with large depth of field, focused at a certain plane in front of the microlenses. For the purpose of digital refocusing (which is one of the important applications) the depth of field needs to be large, but there are fundamental optical limitations to this. The solution of the above problem is to use and array of interleaved microlenses of different focal lengths, focused at two or more different planes. In this way a focused image can be constructed at any depth of focus, and a really wide range of digital refocusing can be achieved. This paper presents our theory and results of implementing such camera. Real world images are demonstrating the extended capabilities, and limitations are discussed.

  13. The PanCam instrument on the 2018 Exomars rover: Science Implementation Strategy and Integrated Surface Operations Concept

    NASA Astrophysics Data System (ADS)

    Schmitz, Nicole; Jaumann, Ralf; Coates, Andrew; Griffiths, Andrew; Hauber, Ernst; Trauthan, Frank; Paar, Gerhard; Barnes, Dave; Bauer, Arnold; Cousins, Claire

    2010-05-01

    Geologic context as a combination of orbital imaging and surface vision, including range, resolution, stereo, and multispectral imaging, is commonly regarded as basic requirement for remote robotic geology and forms the first tier of any multi-instrument strategy for investigating and eventually understanding the geology of a region from a robotic platform. Missions with objectives beyond a pure geologic survey, e.g. exobiology objectives, require goal-oriented operational procedures, where the iterative process of scientific observation, hypothesis, testing, and synthesis, performed via a sol-by-sol data exchange with a remote robot, is supported by a powerful vision system. Beyond allowing a thorough geological mapping of the surface (soil, rocks and outcrops) in 3D, using wide angle stereo imagery, such a system needs to be able to provide detailed visual information on targets of interest in high resolution, thereby enabling the selection of science targets and samples for further analysis with a specialized in-situ instrument suite. Surface vision for ESA's upcoming ExoMars rover will come from a dedicated Panoramic Camera System (PanCam). As integral part of the Pasteur payload package, the PanCam is designed to support the search for evidence of biological processes by obtaining wide angle multispectral stereoscopic panoramic images and high resolution RGB images from the mast of the rover [1]. The camera system will consist of two identical wide-angle cameras (WACs), which are arranged on a common pan-tilt mechanism, with a fixed stereo base length of 50 cm. The WACs are being complemented by a High Resolution Camera (HRC), mounted between the WACs, which allows a magnification of selected targets by a factor of ~8 with respect to the wide-angle optics. The high-resolution images together with the multispectral and stereo capabilities of the camera will be of unprecedented quality for the identification of water-related surface features (such as sedimentary

  14. Rutger's CAM2000 chip architecture

    NASA Technical Reports Server (NTRS)

    Smith, Donald E.; Hall, J. Storrs; Miyake, Keith

    1993-01-01

    This report describes the architecture and instruction set of the Rutgers CAM2000 memory chip. The CAM2000 combines features of Associative Processing (AP), Content Addressable Memory (CAM), and Dynamic Random Access Memory (DRAM) in a single chip package that is not only DRAM compatible but capable of applying simple massively parallel operations to memory. This document reflects the current status of the CAM2000 architecture and is continually updated to reflect the current state of the architecture and instruction set.

  15. CAM Photosynthesis in Submerged Aquatic Plants

    USGS Publications Warehouse

    Keeley, J.E.

    1998-01-01

    Crassulacean acid metabolism (CAM) is a CO2-concentrating mechanism selected in response to aridity in terrestrial habitats, and, in aquatic environments, to ambient limitations of carbon. Evidence is reviewed for its presence in five genera of aquatic vascular plants, including Isoe??tes, Sagittaria, Vallisneria, Crassula, and Littorella. Initially, aquatic CAM was considered by some to be an oxymoron, but some aquatic species have been studied in sufficient detail to say definitively that they possess CAM photosynthesis. CO2-concentrating mechanisms in photosynthetic organs require a barrier to leakage; e.g., terrestrial C4 plants have suberized bundle sheath cells and terrestrial CAM plants high stomatal resistance. In aquatic CAM plants the primary barrier to CO2 leakage is the extremely high diffusional resistance of water. This, coupled with the sink provided by extensive intercellular gas space, generates daytime CO2(Pi) comparable to terrestrial CAM plants. CAM contributes to the carbon budget by both net carbon gain and carbon recycling, and the magnitude of each is environmentally influenced. Aquatic CAM plants inhabit sites where photosynthesis is potentially limited by carbon. Many occupy moderately fertile shallow temporary pools that experience extreme diel fluctuations in carbon availability. CAM plants are able to take advantage of elevated nighttime CO2 levels in these habitats. This gives them a competitive advantage over non-CAM species that are carbon starved during the day and an advantage over species that expend energy in membrane transport of bicarbonate. Some aquatic CAM plants are distributed in highly infertile lakes, where extreme carbon limitation and light are important selective factors. Compilation of reports on diel changes in titratable acidity and malate show 69 out of 180 species have significant overnight accumulation, although evidence is presented discounting CAM in some. It is concluded that similar proportions of the aquatic

  16. 3D-CAM: Derivation and Validation of a 3-Minute Diagnostic Interview for CAM-defined Delirium

    PubMed Central

    Marcantonio, Edward R.; Ngo, Long H.; O’Connor, Margaret; Jones, Richard N.; Crane, Paul K.; Metzger, Eran D.; Inouye, Sharon K.

    2015-01-01

    Background Delirium is common, morbid, and costly, yet remains often unrecognized in most clinical settings. The Confusion Assessment Method (CAM) is the most widely used diagnostic algorithm, and operationalizing its features would represent a substantial advance for clinical care. Objective To derive the 3D-CAM, a new 3-minute diagnostic assessment for CAM-defined delirium, and to validate it against a clinical reference standard. Design Diagnostic test study Setting 4 general medicine units in an academic medical center Participants 201 inpatients aged ≥ 75 years old Measurements We identified 20 items that best operationalized the 4 CAM diagnostic features to create the 3D-CAM. For prospective validation, 3D-CAM assessments were administered by trained research assistants. Independently, clinicians performed an extensive assessment that included patient interviews, family interviews, and review of the medical record. These data were considered by an expert panel to determine the presence or absence of delirium and dementia (reference standard). We compared the 3D-CAM delirium determination to the reference standard in all patients and in subgroups with and without dementia. Results The 201 participants in the prospective validation study had mean age (SD) of 84 (5.5) years, and 27% had dementia. The expert panel identified delirium in 21%. Median administration time for 3D-CAM was 3 minutes (inter-quartile range: 2–5 minutes). The sensitivity [95% CI] of 3D-CAM was 95% [84%, 99%] and the specificity was 94% [90%, 97%]. The 3D-CAM performed well in patients both with dementia (sensitivity=96% [82%, 100%], specificity=86% [67%, 96%]) and without dementia (sensitivity=93% [66%, 100%], specificity=96% [91%,99%]). Limitations Limited to single center, cross-sectional, and medicine patients only Conclusion The 3D-CAM operationalizes the CAM algorithm using a 3-minute structured assessment with high sensitivity and specificity relative to a reference standard and

  17. A scoping review of research on complementary and alternative medicine (CAM) and the mass media: looking back, moving forward.

    PubMed

    Weeks, Laura C; Strudsholm, Tina

    2008-07-19

    The use of complementary and alternative medicine (CAM) has become more common in Western developed countries in recent years, as has media reporting on CAM and related issues. Correspondingly, media reports are a primary information source regarding decisions to use CAM. Research on CAM related media reports is becoming increasingly relevant and important; however, identifying key concepts to guide future research is problematic due to the dispersed nature of completed research in this field. A scoping review was conducted to: 1) determine the amount, focus and nature of research on CAM and the mass media; and 2) summarize and disseminate related research results. The main phases were: 1) searching for relevant studies; 2) selecting studies based on pre-defined inclusion criteria; 3) extracting data; and 4) collating, summarizing and reporting the results. Of 4,454 studies identified through various search strategies, 16 were relevant to our objectives and included in a final sample. CAM and media research has focused primarily on print media coverage of a range of CAM therapies, although only a few studies articulated differences within the range of therapies surveyed. Research has been developed through a variety of disciplinary perspectives, with a focus on representation research. The research reviewed suggests that journalists draw on a range of sources to prepare media reports, although most commonly they cite conventional (versus CAM) sources and personal anecdotes. The tone of media reports appears generally positive, which may be related to a lack of reporting on issues related to risk and safety. Finally, a variety of discourses within media representations of CAM are apparent that each appeal to a specific audience through resonance with their specific concerns. Research on CAM and the mass media spans multiple disciplines and strategies of inquiry; however, despite the diversity in approach, it is clear that issues related to production and reception

  18. Machine-learning-based real-bogus system for the HSC-SSP moving object detection pipeline

    NASA Astrophysics Data System (ADS)

    Lin, Hsing-Wen; Chen, Ying-Tung; Wang, Jen-Hung; Wang, Shiang-Yu; Yoshida, Fumi; Ip, Wing-Huen; Miyazaki, Satoshi; Terai, Tsuyoshi

    2018-01-01

    Machine-learning techniques are widely applied in many modern optical sky surveys, e.g., Pan-STARRS1, PTF/iPTF, and the Subaru/Hyper Suprime-Cam survey, to reduce human intervention in data verification. In this study, we have established a machine-learning-based real-bogus system to reject false detections in the Subaru/Hyper-Suprime-Cam Strategic Survey Program (HSC-SSP) source catalog. Therefore, the HSC-SSP moving object detection pipeline can operate more effectively due to the reduction of false positives. To train the real-bogus system, we use stationary sources as the real training set and "flagged" data as the bogus set. The training set contains 47 features, most of which are photometric measurements and shape moments generated from the HSC image reduction pipeline (hscPipe). Our system can reach a true positive rate (tpr) ˜96% with a false positive rate (fpr) ˜1% or tpr ˜99% at fpr ˜5%. Therefore, we conclude that stationary sources are decent real training samples, and using photometry measurements and shape moments can reject false positives effectively.

  19. The effects of end-of-day picture review and a sensor-based picture capture procedure on autobiographical memory using SenseCam.

    PubMed

    Finley, Jason R; Brewer, William F; Benjamin, Aaron S

    2011-10-01

    Emerging "life-logging" technologies have tremendous potential to augment human autobiographical memory by recording and processing vast amounts of information from an individual's experiences. In this experiment undergraduate participants wore a SenseCam, a small, sensor-equipped digital camera, as they went about their normal daily activities for five consecutive days. Pictures were captured either at fixed intervals or as triggered by SenseCam's sensors. On two of five nights, participants watched an end-of-day review of a random subset of pictures captured that day. Participants were tested with a variety of memory measures at intervals of 1, 3, and 8 weeks. The most fruitful of six measures were recognition rating (on a 1-7 scale) and picture-cued recall length. On these tests, end-of-day review enhanced performance relative to no review, while pictures triggered by SenseCam's sensors showed little difference in performance compared to those taken at fixed time intervals. We discuss the promise of SenseCam as a tool for research and for improving autobiographical memory.

  20. CAM-SE: A scalable spectral element dynamical core for the Community Atmosphere Model.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dennis, John; Edwards, Jim; Evans, Kate J

    2012-01-01

    The Community Atmosphere Model (CAM) version 5 includes a spectral element dynamical core option from NCAR's High-Order Method Modeling Environment. It is a continuous Galerkin spectral finite element method designed for fully unstructured quadrilateral meshes. The current configurations in CAM are based on the cubed-sphere grid. The main motivation for including a spectral element dynamical core is to improve the scalability of CAM by allowing quasi-uniform grids for the sphere that do not require polar filters. In addition, the approach provides other state-of-the-art capabilities such as improved conservation properties. Spectral elements are used for the horizontal discretization, while most othermore » aspects of the dynamical core are a hybrid of well tested techniques from CAM's finite volume and global spectral dynamical core options. Here we first give a overview of the spectral element dynamical core as used in CAM. We then give scalability and performance results from CAM running with three different dynamical core options within the Community Earth System Model, using a pre-industrial time-slice configuration. We focus on high resolution simulations of 1/4 degree, 1/8 degree, and T340 spectral truncation.« less

  1. Wide-Angle Polarimetric Camera for Korea Pathfinder Lunar Orbiter

    NASA Astrophysics Data System (ADS)

    Choi, Y. J.; Kim, S.; Kang, K. I.

    2016-12-01

    A polarimetry data contains valuable information about the lunar surface such as the grain size and porosity of the regolith. However, a polarimetry toward the Moon in its orbit has not been performed. We plan to perform the polarimetry in lunar orbit through Korea Pathfinder Lunar Orbiter (KPLO), which will be launched around 2018/2019 as the first Korean lunar mission. Wide-Angle Polarimetric Camera (PolCam) is selected as one of the onboard instrument for KPLO. The science objectives are ; (1) To obtain the polarization data of the whole lunar surface at wavelengths of 430nm and 650nm for phase angle range from 0° to 120° with a spatial resolution of 80 m. (2) To obtain the reflectance ratios at 320 nm and 430 nm for the whole lunar surface with a spatial resolution of 80m. We will summarize recent results of lunar surface from ground-based polarimetric observations and will briefly introduce the science rationals and operation concept of PolCam.

  2. Patterns of complementary and alternative medicine (CAM) use in children: a systematic review.

    PubMed

    Italia, Salvatore; Wolfenstetter, Silke Britta; Teuner, Christina Maria

    2014-11-01

    Utilization of complementary and alternative medicine (CAM) among children/adolescents is popular. This review summarizes the international findings for prevalence and predictors of CAM use among children/adolescents. We therefore systematically searched four electronic databases (PubMed, Embase, PsycINFO, AMED; last update in 07/2013) and reference lists of existing reviews and all included studies. Publications without language restriction reporting patterns of CAM utilization among children/adolescents without chronic conditions were selected for inclusion. The prevalence rates for overall CAM use, homeopathy, and herbal drug use were extracted with a focus on country and recall period (lifetime, 1 year, current use). As predictors, we extracted socioeconomic factors, child's age, and gender. The database search and citation tracking yielded 58 eligible studies from 19 countries. There was strong variation regarding study quality. Prevalence rates for overall CAM use ranged from 10.9-87.6 % for lifetime use and from 8-48.5 % for current use. The respective percentages for homeopathy (highest in Germany, United Kingdom, and Canada) ranged from 0.8-39 % (lifetime) and from 1-14.3 % (current). Herbal drug use (highest in Germany, Turkey, and Brazil) was reported for 0.8-85.5 % (lifetime) and 2.2-8.9 % (current) of the children/adolescents. Studies provided a relatively uniform picture of the predictors of overall CAM use (higher parental income and education, older children), but only a few studies analyzed predictors for single CAM modalities. CAM use is widespread among children/adolescents. Prevalence rates vary widely regarding CAM modality, country, and reported recall period.

  3. Ecophysiology of Crassulacean Acid Metabolism (CAM).

    PubMed

    Lüttge, Ulrich

    2004-06-01

    Crassulacean Acid Metabolism (CAM) as an ecophysiological modification of photosynthetic carbon acquisition has been reviewed extensively before. Cell biology, enzymology and the flow of carbon along various pathways and through various cellular compartments have been well documented and discussed. The present attempt at reviewing CAM once again tries to use a different approach, considering a wide range of inputs, receivers and outputs. Input is given by a network of environmental parameters. Six major ones, CO(2), H(2)O, light, temperature, nutrients and salinity, are considered in detail, which allows discussion of the effects of these factors, and combinations thereof, at the individual plant level ('physiological aut-ecology'). Receivers of the environmental cues are the plant types genotypes and phenotypes, the latter including morphotypes and physiotypes. CAM genotypes largely remain 'black boxes', and research endeavours of genomics, producing mutants and following molecular phylogeny, are just beginning. There is no special development of CAM morphotypes except for a strong tendency for leaf or stem succulence with large cells with big vacuoles and often, but not always, special water storage tissues. Various CAM physiotypes with differing degrees of CAM expression are well characterized. Output is the shaping of habitats, ecosystems and communities by CAM. A number of systems are briefly surveyed, namely aquatic systems, deserts, salinas, savannas, restingas, various types of forests, inselbergs and paramós. While quantitative census data for CAM diversity and biomass are largely missing, intuition suggests that the larger CAM domains are those systems which are governed by a network of interacting stress factors requiring versatile responses and not systems where a single stress factor strongly prevails. CAM is noted to be a strategy for variable, flexible and plastic niche occupation rather than lush productivity. 'Physiological syn-ecology' reveals

  4. THE DARK ENERGY CAMERA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Flaugher, B.; Diehl, H. T.; Alvarez, O.

    2015-11-15

    The Dark Energy Camera is a new imager with a 2.°2 diameter field of view mounted at the prime focus of the Victor M. Blanco 4 m telescope on Cerro Tololo near La Serena, Chile. The camera was designed and constructed by the Dark Energy Survey Collaboration and meets or exceeds the stringent requirements designed for the wide-field and supernova surveys for which the collaboration uses it. The camera consists of a five-element optical corrector, seven filters, a shutter with a 60 cm aperture, and a charge-coupled device (CCD) focal plane of 250 μm thick fully depleted CCDs cooled inside a vacuummore » Dewar. The 570 megapixel focal plane comprises 62 2k × 4k CCDs for imaging and 12 2k × 2k CCDs for guiding and focus. The CCDs have 15 μm × 15 μm pixels with a plate scale of 0.″263 pixel{sup −1}. A hexapod system provides state-of-the-art focus and alignment capability. The camera is read out in 20 s with 6–9 electron readout noise. This paper provides a technical description of the camera's engineering, construction, installation, and current status.« less

  5. The Dark Energy Camera

    DOE PAGES

    Flaugher, B.

    2015-04-11

    The Dark Energy Camera is a new imager with a 2.2-degree diameter field of view mounted at the prime focus of the Victor M. Blanco 4-meter telescope on Cerro Tololo near La Serena, Chile. The camera was designed and constructed by the Dark Energy Survey Collaboration, and meets or exceeds the stringent requirements designed for the wide-field and supernova surveys for which the collaboration uses it. The camera consists of a five element optical corrector, seven filters, a shutter with a 60 cm aperture, and a CCD focal plane of 250-μm thick fully depleted CCDs cooled inside a vacuum Dewar.more » The 570 Mpixel focal plane comprises 62 2k x 4k CCDs for imaging and 12 2k x 2k CCDs for guiding and focus. The CCDs have 15μm x 15μm pixels with a plate scale of 0.263" per pixel. A hexapod system provides state-of-the-art focus and alignment capability. The camera is read out in 20 seconds with 6-9 electrons readout noise. This paper provides a technical description of the camera's engineering, construction, installation, and current status.« less

  6. The Role of Public Interaction with the Juno Mission: Documentation, Discussion, Selection and Processing of JunoCam Images of Jovian Cloud Features

    NASA Astrophysics Data System (ADS)

    Orton, Glenn; Hansen, Candice; Momary, Thomas; Bolton, Scott

    2017-04-01

    Among the many "firsts" of the Juno mission is the open enlistment of the public in the operation of its visible camera, JunoCam. Although the scientific thrust of the Juno mission is largely focused on innovative approaches to understanding the structure and composition of Jupiter's interior, JunoCam was added to the payload largely to function in the role of education and public outreach (E/PO). For the first time, the public was able to engage in the discussion and choice of targets for a major NASA mission. The discussion about which features to image is enabled by a continuously updated map of Jupiter's cloud system while Jupiter is far enough from the sun to be observable by non-professional astronomers. Contributors range from very devoted astrophotographers to telescope and video 'hobbyists'. Juno therefore engages the world-wide amateur-astronomy community as a vast network of co-investigators, whose products stimulate conversation and global public awareness of Jupiter and Juno's investigative role. Contributed images also provide a temporal context to inform the Juno atmospheric investigation team of the state and evolution of the atmosphere. The contributed images are used to create s global map on a bi-weekly basis. These bi-weekly maps provide the focus for ongoing discussion about various planetary features over a long time frame. Approximately two weeks before Juno's closest approach to Jupiter on each orbit ("perijove" or PJ), starting in mid-November of 2016 in preparation for PJ3 on December 11, the atmospheric features that have been under discussion and available to JunoCam on that perijove were nominated for voting, and the public at large voted on where to point JunoCam's "elective" features. In addition, JunoCam provides the first close-up images of Jupiter's polar regions from a non-oblique viewpoint for the first time in over 40 years since the passage of Pioneer 11 over Jupiter's north pole. The Juno mission science team also provides

  7. Ringfield lithographic camera

    DOEpatents

    Sweatt, William C.

    1998-01-01

    A projection lithography camera is presented with a wide ringfield optimized so as to make efficient use of extreme ultraviolet radiation from a large area radiation source (e.g., D.sub.source .apprxeq.0.5 mm). The camera comprises four aspheric mirrors optically arranged on a common axis of symmetry with an increased etendue for the camera system. The camera includes an aperture stop that is accessible through a plurality of partial aperture stops to synthesize the theoretical aperture stop. Radiation from a mask is focused to form a reduced image on a wafer, relative to the mask, by reflection from the four aspheric mirrors.

  8. Airborne camera and spectrometer experiments and data evaluation

    NASA Astrophysics Data System (ADS)

    Lehmann, F. F.; Bucher, T.; Pless, S.; Wohlfeil, J.; Hirschmüller, H.

    2009-09-01

    New stereo push broom camera systems have been developed at German Aerospace Centre (DLR). The new small multispectral systems (Multi Functional Camerahead - MFC, Advanced Multispectral Scanner - AMS) are light weight, compact and display three or five RGB stereo lines of 8000, 10 000 or 14 000 pixels, which are used for stereo processing and the generation of Digital Surface Models (DSM) and near True Orthoimage Mosaics (TOM). Simultaneous acquisition of different types of MFC-cameras for infrared and RGB data has been successfully tested. All spectral channels record the image data in full resolution, pan-sharpening is not necessary. Analogue to the line scanner data an automatic processing chain for UltraCamD and UltraCamX exists. The different systems have been flown for different types of applications; main fields of interest among others are environmental applications (flooding simulations, monitoring tasks, classification) and 3D-modelling (e.g. city mapping). From the DSM and TOM data Digital Terrain Models (DTM) and 3D city models are derived. Textures for the facades are taken from oblique orthoimages, which are created from the same input data as the TOM and the DOM. The resulting models are characterised by high geometric accuracy and the perfect fit of image data and DSM. The DLR is permanently developing and testing a wide range of sensor types and imaging platforms for terrestrial and space applications. The MFC-sensors have been flown in combination with laser systems and imaging spectrometers and special data fusion products have been developed. These products include hyperspectral orthoimages and 3D hyperspectral data.

  9. A scoping review of research on complementary and alternative medicine (CAM) and the mass media: Looking back, moving forward

    PubMed Central

    Weeks, Laura C; Strudsholm, Tina

    2008-01-01

    Background The use of complementary and alternative medicine (CAM) has become more common in Western developed countries in recent years, as has media reporting on CAM and related issues. Correspondingly, media reports are a primary information source regarding decisions to use CAM. Research on CAM related media reports is becoming increasingly relevant and important; however, identifying key concepts to guide future research is problematic due to the dispersed nature of completed research in this field. A scoping review was conducted to: 1) determine the amount, focus and nature of research on CAM and the mass media; and 2) summarize and disseminate related research results. Methods The main phases were: 1) searching for relevant studies; 2) selecting studies based on pre-defined inclusion criteria; 3) extracting data; and 4) collating, summarizing and reporting the results. Results Of 4,454 studies identified through various search strategies, 16 were relevant to our objectives and included in a final sample. CAM and media research has focused primarily on print media coverage of a range of CAM therapies, although only a few studies articulated differences within the range of therapies surveyed. Research has been developed through a variety of disciplinary perspectives, with a focus on representation research. The research reviewed suggests that journalists draw on a range of sources to prepare media reports, although most commonly they cite conventional (versus CAM) sources and personal anecdotes. The tone of media reports appears generally positive, which may be related to a lack of reporting on issues related to risk and safety. Finally, a variety of discourses within media representations of CAM are apparent that each appeal to a specific audience through resonance with their specific concerns. Conclusion Research on CAM and the mass media spans multiple disciplines and strategies of inquiry; however, despite the diversity in approach, it is clear that issues

  10. Ecophysiology of Crassulacean Acid Metabolism (CAM)

    PubMed Central

    LÜTTGE, ULRICH

    2004-01-01

    • Background and Scope Crassulacean Acid Metabolism (CAM) as an ecophysiological modification of photosynthetic carbon acquisition has been reviewed extensively before. Cell biology, enzymology and the flow of carbon along various pathways and through various cellular compartments have been well documented and discussed. The present attempt at reviewing CAM once again tries to use a different approach, considering a wide range of inputs, receivers and outputs. • Input Input is given by a network of environmental parameters. Six major ones, CO2, H2O, light, temperature, nutrients and salinity, are considered in detail, which allows discussion of the effects of these factors, and combinations thereof, at the individual plant level (‘physiological aut‐ecology’). • Receivers Receivers of the environmental cues are the plant types genotypes and phenotypes, the latter including morphotypes and physiotypes. CAM genotypes largely remain ‘black boxes’, and research endeavours of genomics, producing mutants and following molecular phylogeny, are just beginning. There is no special development of CAM morphotypes except for a strong tendency for leaf or stem succulence with large cells with big vacuoles and often, but not always, special water storage tissues. Various CAM physiotypes with differing degrees of CAM expression are well characterized. • Output Output is the shaping of habitats, ecosystems and communities by CAM. A number of systems are briefly surveyed, namely aquatic systems, deserts, salinas, savannas, restingas, various types of forests, inselbergs and paramós. • Conclusions While quantitative census data for CAM diversity and biomass are largely missing, intuition suggests that the larger CAM domains are those systems which are governed by a network of interacting stress factors requiring versatile responses and not systems where a single stress factor strongly prevails. CAM is noted to be a strategy for variable, flexible and plastic

  11. Wearable cameras can reduce dietary under-reporting: doubly labelled water validation of a camera-assisted 24 h recall.

    PubMed

    Gemming, Luke; Rush, Elaine; Maddison, Ralph; Doherty, Aiden; Gant, Nicholas; Utter, Jennifer; Ni Mhurchu, Cliona

    2015-01-28

    Preliminary research has suggested that wearable cameras may reduce under-reporting of energy intake (EI) in self-reported dietary assessment. The aim of the present study was to test the validity of a wearable camera-assisted 24 h dietary recall against the doubly labelled water (DLW) technique. Total energy expenditure (TEE) was assessed over 15 d using the DLW protocol among forty adults (n 20 males, age 35 (sd 17) years, BMI 27 (sd 4) kg/m2 and n 20 females, age 28 (sd 7) years, BMI 22 (sd 2) kg/m2). EI was assessed using three multiple-pass 24 h dietary recalls (MP24) on days 2-4, 8-10 and 13-15. On the days before each nutrition assessment, participants wore an automated wearable camera (SenseCam (SC)) in free-living conditions. The wearable camera images were viewed by the participants following the completion of the dietary recall, and their changes in self-reported intakes were recorded (MP24+SC). TEE and EI assessed by the MP24 and MP24+SC methods were compared. Among men, the MP24 and MP24+SC measures underestimated TEE by 17 and 9%, respectively (P< 0.001 and P= 0.02). Among women, these measures underestimated TEE by 13 and 7%, respectively (P< 0.001 and P= 0.004). The assistance of the wearable camera (MP24+SC) reduced the magnitude of under-reporting by 8% for men and 6% for women compared with the MP24 alone (P< 0.001 and P< 0.001). The increase in EI was predominantly from the addition of 265 unreported foods (often snacks) as revealed by the participants during the image review. Wearable cameras enhance the accuracy of self-report by providing passive and objective information regarding dietary intake. High-definition image sensors and increased imaging frequency may improve the accuracy further.

  12. Constrained space camera assembly

    DOEpatents

    Heckendorn, F.M.; Anderson, E.K.; Robinson, C.W.; Haynes, H.B.

    1999-05-11

    A constrained space camera assembly which is intended to be lowered through a hole into a tank, a borehole or another cavity is disclosed. The assembly includes a generally cylindrical chamber comprising a head and a body and a wiring-carrying conduit extending from the chamber. Means are included in the chamber for rotating the body about the head without breaking an airtight seal formed therebetween. The assembly may be pressurized and accompanied with a pressure sensing means for sensing if a breach has occurred in the assembly. In one embodiment, two cameras, separated from their respective lenses, are installed on a mounting apparatus disposed in the chamber. The mounting apparatus includes means allowing both longitudinal and lateral movement of the cameras. Moving the cameras longitudinally focuses the cameras, and moving the cameras laterally away from one another effectively converges the cameras so that close objects can be viewed. The assembly further includes means for moving lenses of different magnification forward of the cameras. 17 figs.

  13. Constrained space camera assembly

    DOEpatents

    Heckendorn, Frank M.; Anderson, Erin K.; Robinson, Casandra W.; Haynes, Harriet B.

    1999-01-01

    A constrained space camera assembly which is intended to be lowered through a hole into a tank, a borehole or another cavity. The assembly includes a generally cylindrical chamber comprising a head and a body and a wiring-carrying conduit extending from the chamber. Means are included in the chamber for rotating the body about the head without breaking an airtight seal formed therebetween. The assembly may be pressurized and accompanied with a pressure sensing means for sensing if a breach has occurred in the assembly. In one embodiment, two cameras, separated from their respective lenses, are installed on a mounting apparatus disposed in the chamber. The mounting apparatus includes means allowing both longitudinal and lateral movement of the cameras. Moving the cameras longitudinally focuses the cameras, and moving the cameras laterally away from one another effectively converges the cameras so that close objects can be viewed. The assembly further includes means for moving lenses of different magnification forward of the cameras.

  14. Interprofessional education: merging nursing, midwifery and CAM.

    PubMed

    Netherwood, Maggie; Derham, Ruth

    To ascertain the value of bringing together undergraduate students from nursing, midwifery, and complementary and alternative medicine (CAM) to determine what they could learn from each other. Interprofessional education (IPE) is a growing field promoting interaction between professional groups, collaborative working and quality of health. In conventional health, IPE has a role to play in undergraduate education. No studies have been undertaken to investigate the integration of CAM students and conventional undergraduate healthcare students. In a mixed-method study, in 2010, a sample of third-year students enrolled on adult nursing, midwifery, homeopathy and complementary therapies degree courses took part in two workshops and a focus-group discussion. Six themes were identified from qualitative data analysis: interaction; breaking down prejudices; knowledge of self; knowledge of others; common aims; and organisational limitations. The common aim of patient-centred care allowed students to recognise the benefits of a more integrated health system.

  15. Comparative study of RetCamRetCam II vs. binocular ophthalmoscopy in a screening program for retinopathy of prematurity.

    PubMed

    Tejada-Palacios, P; Zarratea, L; Moral, M; de la Cruz-Bértolo, J

    2015-08-01

    To determine the performance of RetCam vs. binocular ophthalmoscopy (BIO) in a screening program for retinopathy of prematurity (ROP). Observational comparative study with prospective data collection. Examinations with RetCam (n=169) were performed on 83 infants included in a screening program for ROP and stored for analysis at a later stage. An experienced ophthalmologist examined the ocular fundus with binocular indirect ophthalmoscopy (BIO). The RetCam images were assessed for the presence of ROP, zone, grade, and presence of plus disease. RetCam and BIO data were compared by visually to estimate sensitivity, specificity, positive (VPP) and negative (VPN) predictive values. ROP disease was detected in 108 eyes with BIO, and in 74 with RetCam. Out of 306 eyes examined with RetCam, false negative results were found in 34 eyes, with no false positives. Sensitivity of RetCam exam vs. BIO was 0.68, and specificity was 0.99. Positive predictive value was 0.93 and negative predictive value was 0.85. All 34 ROP cases not detected with RetCam were in zone III or outer zone II. They were all mild and regressed spontaneously. No threshold ROP was missed with RetCam. Binocular indirect ophthalmoscopy is the reference method for the diagnosis of ROP. RetCam may be used as an alternative for ROP screening. Copyright © 2010 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  16. The SLUGGS Survey: HST/ACS Mosaic Imaging of the NGC 3115 Globular Cluster System

    NASA Astrophysics Data System (ADS)

    Jennings, Zachary G.; Strader, Jay; Romanowsky, Aaron J.; Brodie, Jean P.; Arnold, Jacob A.; Lin, Dacheng; Irwin, Jimmy A.; Sivakoff, Gregory R.; Wong, Ka-Wah

    2014-08-01

    We present Hubble Space Telescope/Advanced Camera for Surveys (HST/ACS) g and z photometry and half-light radii R h measurements of 360 globular cluster (GC) candidates around the nearby S0 galaxy NGC 3115. We also include Subaru/Suprime-Cam g, r, and i photometry of 421 additional candidates. The well-established color bimodality of the GC system is obvious in the HST/ACS photometry. We find evidence for a "blue tilt" in the blue GC subpopulation, wherein the GCs in the blue subpopulation get redder as luminosity increases, indicative of a mass-metallicity relationship. We find a color gradient in both the red and blue subpopulations, with each group of clusters becoming bluer at larger distances from NGC 3115. The gradient is of similar strength in both subpopulations, but is monotonic and more significant for the blue clusters. On average, the blue clusters have ~10% larger R h than the red clusters. This average difference is less than is typically observed for early-type galaxies but does match that measured in the literature for the Sombrero Galaxy (M104), suggesting that morphology and inclination may affect the measured size difference between the red and blue clusters. However, the scatter on the R h measurements is large. We also identify 31 clusters more extended than typical GCs, which we term ultra-compact dwarf (UCD) candidates. Many of these objects are actually considerably fainter than typical UCDs. While it is likely that a significant number will be background contaminants, six of these UCD candidates are spectroscopically confirmed as NGC 3115 members. To explore the prevalence of low-mass X-ray binaries in the GC system, we match our ACS and Suprime-Cam detections to corresponding Chandra X-ray sources. We identify 45 X-ray-GC matches: 16 among the blue subpopulation and 29 among the red subpopulation. These X-ray/GC coincidence fractions are larger than is typical for most GC systems, probably due to the increased depth of the X-ray data

  17. HST Imaging of the Brightest z ∼ 8–9 Galaxies from UltraVISTA: The Extreme Bright End of the UV Luminosity Function

    NASA Astrophysics Data System (ADS)

    Stefanon, Mauro; Labbé, Ivo; Bouwens, Rychard J.; Brammer, Gabriel B.; Oesch, Pascal; Franx, Marijn; Fynbo, Johan P. U.; Milvang-Jensen, Bo; Muzzin, Adam; Illingworth, Garth D.; Le Fèvre, Olivier; Caputi, Karina I.; Holwerda, Benne W.; McCracken, Henry J.; Smit, Renske; Magee, Dan

    2017-12-01

    We report on the discovery of three especially bright candidate {z}{phot}≳ 8 galaxies. Five sources were targeted for follow-up with the Hubble Space Telescope (HST)/Wide Field Camera 3 (WFC3), selected from a larger sample of 16 bright (24.8≲ H≲ 25.5 mag) candidate z≳ 8 Lyman break galaxies (LBGs) identified over 1.6 degrees2 of the COSMOS/UltraVISTA field. These were selected as Y and J dropouts by leveraging the deep (Y-to-{K}{{S}}∼ 25.3{--}24.8 mag, 5σ ) NIR data from the UltraVISTA DR3 release, deep ground-based optical imaging from the CFHTLS and Suprime-Cam programs, and Spitzer/IRAC mosaics combining observations from the SMUVS and SPLASH programs. Through the refined spectral energy distributions, which now also include new HyperSuprimeCam g-, r-, i-, z-, and Y-band data, we confirm that 3/5 galaxies have robust {z}{phot}∼ 8.0{--}8.7, consistent with the initial selection. The remaining 2/5 galaxies have a nominal {z}{phot}∼ 2. However, with HST data alone, these objects have increased probability of being at z∼ 9. We measure mean UV continuum slopes β =-1.74+/- 0.35 for the three z∼ 8{--}9 galaxies, marginally bluer than similarly luminous z∼ 4{--}6 in CANDELS but consistent with previous measurements of similarly luminous galaxies at z∼ 7. The circularized effective radius for our brightest source is 0.9 ± 0.3 kpc, similar to previous measurements for a bright z∼ 11 galaxy and bright z∼ 7 galaxies. Finally, enlarging our sample to include the six brightest z∼ 8 LBGs identified over UltraVISTA (i.e., including three other sources from Labbé et al.) we estimate for the first time the volume density of galaxies at the extreme bright end ({M}{UV}∼ -22 mag) of the z∼ 8 UV luminosity function. Despite this exceptional result, the still large statistical uncertainties do not allow us to discriminate between a Schechter and a double-power-law form.

  18. CAD/CAM. High-Technology Training Module.

    ERIC Educational Resources Information Center

    Zuleger, Robert

    This high technology training module is an advanced course on computer-assisted design/computer-assisted manufacturing (CAD/CAM) for grades 11 and 12. This unit, to be used with students in advanced drafting courses, introduces the concept of CAD/CAM. The content outline includes the following seven sections: (1) CAD/CAM software; (2) computer…

  19. Exploration of Mars with the ChemCam LIBS Instrument and the Curiosity Rover

    NASA Technical Reports Server (NTRS)

    Newsom, Horton E.

    2016-01-01

    The Mars Science Laboratory (MSL) Curiosity rover landed on Mars in August 2012, and has been exploring the planet ever since. Dr. Horton E. Newsom will discuss the MSL's design and main goal, which is to characterize past environments that may have been conducive to the evolution and sustainability of life. He will also discuss Curiosity's science payload, and remote sensing, analytical capabilities, and direct discoveries of the Chemistry & Camera (ChemCam) instrument, which is the first Laser Induced Breakdown Spectrometer (LIBS) to operate on another planetary surface and determine the chemistry of the rocks and soils.

  20. Evaluation of marginal fit of 2 CAD-CAM anatomic contour zirconia crown systems and lithium disilicate glass-ceramic crown.

    PubMed

    Ji, Min-Kyung; Park, Ji-Hee; Park, Sang-Won; Yun, Kwi-Dug; Oh, Gye-Jeong; Lim, Hyun-Pil

    2015-08-01

    This study was to evaluate the marginal fit of two CAD-CAM anatomic contour zirconia crown systems compared to lithium disilicate glass-ceramic crowns. Shoulder and deep chamfer margin were formed on each acrylic resin tooth model of a maxillary first premolar. Two CAD-CAM systems (Prettau®Zirconia and ZENOSTAR®ZR translucent) and lithium disilicate glass ceramic (IPS e.max®press) crowns were made (n=16). Each crown was bonded to stone dies with resin cement (Rely X Unicem). Marginal gap and absolute marginal discrepancy of crowns were measured using a light microscope equipped with a digital camera (Leica DFC295) magnified by a factor of 100. Two-way analysis of variance (ANOVA) and post-hoc Tukey's HSD test were conducted to analyze the significance of crown marginal fit regarding the finish line configuration and the fabrication system. The mean marginal gap of lithium disilicate glass ceramic crowns (IPS e.max®press) was significantly lower than that of the CAD-CAM anatomic contour zirconia crown system (Prettau®Zirconia) (P<.05). Both fabrication systems and finish line configurations significantly influenced the absolute marginal discrepancy (P<.05). The lithium disilicate glass ceramic crown (IPS e.max®press) had significantly smaller marginal gap than the CAD-CAM anatomic contour zirconia crown system (Prettau®Zirconia). In terms of absolute marginal discrepancy, the CAD-CAM anatomic contour zirconia crown system (ZENOSTAR®ZR translucent) had under-extended margin, whereas the CAD-CAM anatomic contour zirconia crown system (Prettau®Zirconia) and lithium disilicate glass ceramic crowns (IPS e.max®press) had overextended margins.

  1. Ringfield lithographic camera

    DOEpatents

    Sweatt, W.C.

    1998-09-08

    A projection lithography camera is presented with a wide ringfield optimized so as to make efficient use of extreme ultraviolet radiation from a large area radiation source (e.g., D{sub source} {approx_equal} 0.5 mm). The camera comprises four aspheric mirrors optically arranged on a common axis of symmetry. The camera includes an aperture stop that is accessible through a plurality of partial aperture stops to synthesize the theoretical aperture stop. Radiation from a mask is focused to form a reduced image on a wafer, relative to the mask, by reflection from the four aspheric mirrors. 11 figs.

  2. CAD/CAM data management

    NASA Technical Reports Server (NTRS)

    Bray, O. H.

    1984-01-01

    The role of data base management in CAD/CAM, particularly for geometric data is described. First, long term and short term objectives for CAD/CAM data management are identified. Second, the benefits of the data base management approach are explained. Third, some of the additional work needed in the data base area is discussed.

  3. Dark Energy Camera for Blanco

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Binder, Gary A.; /Caltech /SLAC

    2010-08-25

    In order to make accurate measurements of dark energy, a system is needed to monitor the focus and alignment of the Dark Energy Camera (DECam) to be located on the Blanco 4m Telescope for the upcoming Dark Energy Survey. One new approach under development is to fit out-of-focus star images to a point spread function from which information about the focus and tilt of the camera can be obtained. As a first test of a new algorithm using this idea, simulated star images produced from a model of DECam in the optics software Zemax were fitted. Then, real images frommore » the Mosaic II imager currently installed on the Blanco telescope were used to investigate the algorithm's capabilities. A number of problems with the algorithm were found, and more work is needed to understand its limitations and improve its capabilities so it can reliably predict camera alignment and focus.« less

  4. Capturing exposures: using automated cameras to document environmental determinants of obesity.

    PubMed

    Barr, Michelle; Signal, Louise; Jenkin, Gabrielle; Smith, Moira

    2015-03-01

    Children's exposure to food marketing across multiple everyday settings, a key environmental influence on health, has not yet been objectively documented. Wearable automated cameras (ACs) may have the potential to provide an objective account of this exposure. The purpose of this study is to assess the feasibility of using ACs to document children's exposure to food marketing in multiple settings. A convenience sample of six participants (aged 12) wore a SenseCam device for two full days. Following which, participants attended a focus group to ascertain their experiences of using the device. The collected data were analysed to determine participants' daily and setting specific exposure to 'healthy' and 'unhealthy' food marketing (in minutes). The focus group transcript was analysed using thematic analysis to identify the common themes. Participants collected usable data that could be analysed to determine participant's daily exposure (in minutes) to 'unhealthy' food marketing across a number of everyday settings. Results from the focus group discussion indicated that participants were comfortable wearing the device, after an initial adjustment period. ACs may be an effective tool for documenting children's exposure to food marketing in multiple settings. ACs provide a new method for documenting environmental determinants of obesity and likely other environmental impacts on health. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. SPLASH-SXDF Multi-wavelength Photometric Catalog

    NASA Astrophysics Data System (ADS)

    Mehta, Vihang; Scarlata, Claudia; Capak, Peter; Davidzon, Iary; Faisst, Andreas; Hsieh, Bau Ching; Ilbert, Olivier; Jarvis, Matt; Laigle, Clotilde; Phillips, John; Silverman, John; Strauss, Michael A.; Tanaka, Masayuki; Bowler, Rebecca; Coupon, Jean; Foucaud, Sébastien; Hemmati, Shoubaneh; Masters, Daniel; McCracken, Henry Joy; Mobasher, Bahram; Ouchi, Masami; Shibuya, Takatoshi; Wang, Wei-Hao

    2018-04-01

    We present a multi-wavelength catalog in the Subaru/XMM-Newton Deep Field (SXDF) as part of the Spitzer Large Area Survey with Hyper-Suprime-Cam (SPLASH). We include the newly acquired optical data from the Hyper-Suprime-Cam Subaru Strategic Program, accompanied by IRAC coverage from the SPLASH survey. All available optical and near-infrared data is homogenized and resampled on a common astrometric reference frame. Source detection is done using a multi-wavelength detection image including the u-band to recover the bluest objects. We measure multi-wavelength photometry and compute photometric redshifts as well as physical properties for ∼1.17 million objects over ∼4.2 deg2, with ∼800,000 objects in the 2.4 deg2 HSC-Ultra-Deep coverage. Using the available spectroscopic redshifts from various surveys over the range of 0 < z < 6, we verify the performance of the photometric redshifts and we find a normalized median absolute deviation of 0.023 and outlier fraction of 3.2%. The SPLASH-SXDF catalog is a valuable, publicly available resource, perfectly suited for studying galaxies in the early universe and tracing their evolution through cosmic time.

  6. Small form-factor VGA camera with variable focus by liquid lens

    NASA Astrophysics Data System (ADS)

    Oikarinen, Kari A.; Aikio, Mika

    2010-05-01

    We present the design of a 24 mm long variable focus lens for 1/4" sensor. The chosen CMOS color sensor has VGA (640×480) resolution and 5.6 μm pixel size. The lens utilizes one Varioptic Arctic 320 liquid lens that has a voltage-controllable focal length due to the electrowetting effect. There are no mechanical moving parts. The principle of operation of the liquid lens is explained briefly. We discuss designing optical systems with this type of lens. This includes a modeling approach that allows entering a voltage value to modify the configuration of the liquid lens. The presented design consists only of spherical glass surfaces. The choice to use spherical surfaces was made in order to decrease the costs of manufacturing and provide more predictable performance by the better established method. Fabrication tolerances are compensated by the adjustability of the liquid lens, further increasing the feasibility of manufacturing. The lens is manufactured and assembled into a demonstrator camera. It has an f-number of 2.5 and 40 degree full field of view. The effective focal length varies around 6 millimeters as the liquid lens is adjusted. In simulations we have achieved a focus distance controllable between 20 millimeters and infinity. The design differs from previous approaches by having the aperture stop in the middle of the system instead of in front.

  7. The Collaborative Assessment and Management of Suicidality (CAMS): an evolving evidence-based clinical approach to suicidal risk.

    PubMed

    Jobes, David A

    2012-12-01

    The Collaborative Assessment and Management of Suicidality (CAMS) is an evidence-based clinical intervention that has significantly evolved over 25 years of clinical research. CAMS is best understood as a therapeutic framework that emphasizes a unique collaborative assessment and treatment planning process between the suicidal patient and clinician. This process is designed to enhance the therapeutic alliance and increase treatment motivation in the suicidal patient. Central to the CAMS approach is the use of the Suicide Status Form (SSF), which is a multipurpose clinical assessment, treatment planning, tracking, and outcome tool. The original development of CAMS was largely rooted in SSF-based quantitative and qualitative assessment of suicidal risk. As this line of research progressed, CAMS emerged as a problem-focused clinical intervention that is designed to target and treat suicidal "drivers" and ultimately eliminate suicidal coping. To date, CAMS (and the clinical use of the SSF) has been supported by six published correlational studies and one randomized clinical trial (RCT). Currently, two well-powered RCTs are under way, and various new CAMS-related projects are also being pursued. The clinical and empirical evolution of CAMS-how it was developed and what are the next steps for this clinical approach-are described here. © 2012 The American Association of Suicidology.

  8. Validity of PALMS GPS scoring of active and passive travel compared with SenseCam.

    PubMed

    Carlson, Jordan A; Jankowska, Marta M; Meseck, Kristin; Godbole, Suneeta; Natarajan, Loki; Raab, Fredric; Demchak, Barry; Patrick, Kevin; Kerr, Jacqueline

    2015-03-01

    The objective of this study is to assess validity of the personal activity location measurement system (PALMS) for deriving time spent walking/running, bicycling, and in vehicle, using SenseCam (Microsoft, Redmond, WA) as the comparison. Forty adult cyclists wore a Qstarz BT-Q1000XT GPS data logger (Qstarz International Co., Taipei, Taiwan) and SenseCam (camera worn around the neck capturing multiple images every minute) for a mean time of 4 d. PALMS used distance and speed between global positioning system (GPS) points to classify whether each minute was part of a trip (yes/no), and if so, the trip mode (walking/running, bicycling, or in vehicle). SenseCam images were annotated to create the same classifications (i.e., trip yes/no and mode). Contingency tables (2 × 2) and confusion matrices were calculated at the minute level for PALMS versus SenseCam classifications. Mixed-effects linear regression models estimated agreement (mean differences and intraclass correlation coefficients) between PALMS and SenseCam with regard to minutes/day in each mode. Minute-level sensitivity, specificity, and negative predictive value were ≥88%, and positive predictive value was ≥75% for non-mode-specific trip detection. Seventy-two percent to 80% of outdoor walking/running minutes, 73% of bicycling minutes, and 74%-76% of in-vehicle minutes were correctly classified by PALMS. For minutes per day, PALMS had a mean bias (i.e., amount of over or under estimation) of 2.4-3.1 min (11%-15%) for walking/running, 2.3-2.9 min (7%-9%) for bicycling, and 4.3-5 min (15%-17%) for vehicle time. Intraclass correlation coefficients were ≥0.80 for all modes. PALMS has validity for processing GPS data to objectively measure time spent walking/running, bicycling, and in vehicle in population studies. Assessing travel patterns is one of many valuable applications of GPS in physical activity research that can improve our understanding of the determinants and health outcomes of active

  9. Volcano monitoring with an infrared camera: first insights from Villarrica Volcano

    NASA Astrophysics Data System (ADS)

    Rosas Sotomayor, Florencia; Amigo Ramos, Alvaro; Velasquez Vargas, Gabriela; Medina, Roxana; Thomas, Helen; Prata, Fred; Geoffroy, Carolina

    2015-04-01

    This contribution focuses on the first trials of the, almost 24/7 monitoring of Villarrica volcano with an infrared camera. Results must be compared with other SO2 remote sensing instruments such as DOAS and UV-camera, for the ''day'' measurements. Infrared remote sensing of volcanic emissions is a fast and safe method to obtain gas abundances in volcanic plumes, in particular when the access to the vent is difficult, during volcanic crisis and at night time. In recent years, a ground-based infrared camera (Nicair) has been developed by Nicarnica Aviation, which quantifies SO2 and ash on volcanic plumes, based on the infrared radiance at specific wavelengths through the application of filters. Three Nicair1 (first model) have been acquired by the Geological Survey of Chile in order to study degassing of active volcanoes. Several trials with the instruments have been performed in northern Chilean volcanoes, and have proven that the intervals of retrieved SO2 concentration and fluxes are as expected. Measurements were also performed at Villarrica volcano, and a location to install a ''fixed'' camera, at 8km from the crater, was discovered here. It is a coffee house with electrical power, wifi network, polite and committed owners and a full view of the volcano summit. The first measurements are being made and processed in order to have full day and week of SO2 emissions, analyze data transfer and storage, improve the remote control of the instrument and notebook in case of breakdown, web-cam/GoPro support, and the goal of the project: which is to implement a fixed station to monitor and study the Villarrica volcano with a Nicair1 integrating and comparing these results with other remote sensing instruments. This works also looks upon the strengthen of bonds with the community by developing teaching material and giving talks to communicate volcanic hazards and other geoscience topics to the people who live "just around the corner" from one of the most active volcanoes

  10. IPAD 2: Advances in Distributed Data Base Management for CAD/CAM

    NASA Technical Reports Server (NTRS)

    Bostic, S. W. (Compiler)

    1984-01-01

    The Integrated Programs for Aerospace-Vehicle Design (IPAD) Project objective is to improve engineering productivity through better use of computer-aided design and manufacturing (CAD/CAM) technology. The focus is on development of technology and associated software for integrated company-wide management of engineering information. The objectives of this conference are as follows: to provide a greater awareness of the critical need by U.S. industry for advancements in distributed CAD/CAM data management capability; to present industry experiences and current and planned research in distributed data base management; and to summarize IPAD data management contributions and their impact on U.S. industry and computer hardware and software vendors.

  11. CAMS meeting 11 March 2018

    NASA Astrophysics Data System (ADS)

    Roggemans, Paul

    2018-03-01

    The annual CAMS BeNeLux meeting took place in Bussloo, Netherlands on 11 March 2018 and was attended by about 25 people. Recent CAMS results were presented and various hardware and software aspects were considered. A summary is presented of the different presentations.

  12. Liquid lens enabling real-time focus and tilt compensation for optical image stabilization in camera modules

    NASA Astrophysics Data System (ADS)

    Simon, Eric; Craen, Pierre; Gaton, Hilario; Jacques-Sermet, Olivier; Laune, Frédéric; Legrand, Julien; Maillard, Mathieu; Tallaron, Nicolas; Verplanck, Nicolas; Berge, Bruno

    2010-05-01

    A new generation of liquid lenses based on electrowetting has been developed, using a multi-electrode design, enabling to induce optical tilt and focus corrections in the same component. The basic principle is to rely on a conical shape for supporting the liquid interface, the conical shape insuring a restoring force for the liquid liquid interface to come at the center position. The multi-electrode design enables to induce an average tilt of the liquid liquid interface when a bias voltage is applied to the different electrodes. This tilt is reversible, vanishing when voltage bias is cancelled. Possible application of this new lens component is the realization of miniature camera featuring auto-focus and optical image stabilization (OIS) without any mobile mechanical part. Experimental measurements of actual performances of liquid lens component will be presented : focus and tilt amplitude, residual optical wave front error and response time.

  13. Laser Transformation Hardening of Firing Zone Cutout Cams.

    DTIC Science & Technology

    1981-06-01

    bath nitriding to case harden firing zone cutout cams for the Mk 10 Guided Missile Launcher System (GMLS). These cams, machined of 4340 steel ...salt bath nitriding to case harden firing zone cutout cams for the Mk 10 Guided Missile Launcher System (GMLS). These cams, machined of 4340 steel ...Patterns ........ ................ 8 9 Laser Beam Step Pattern ...... .................. .. 10 10 Hardness Profile, 4340 Steel

  14. Studying medical communication with video vignettes: a randomized study on how variations in video-vignette introduction format and camera focus influence analogue patients' engagement.

    PubMed

    Visser, Leonie N C; Bol, Nadine; Hillen, Marij A; Verdam, Mathilde G E; de Haes, Hanneke C J M; van Weert, Julia C M; Smets, Ellen M A

    2018-01-19

    Video vignettes are used to test the effects of physicians' communication on patient outcomes. Methodological choices in video-vignette development may have far-stretching consequences for participants' engagement with the video, and thus the ecological validity of this design. To supplement the scant evidence in this field, this study tested how variations in video-vignette introduction format and camera focus influence participants' engagement with a video vignette showing a bad news consultation. Introduction format (A = audiovisual vs. B = written) and camera focus (1 = the physician only, 2 = the physician and the patient at neutral moments alternately, 3 = the physician and the patient at emotional moments alternately) were varied in a randomized 2 × 3 between-subjects design. One hundred eighty-one students were randomly assigned to watch one of the six resulting video-vignette conditions as so-called analogue patients, i.e., they were instructed to imagine themselves being in the video patient's situation. Four dimensions of self-reported engagement were assessed retrospectively. Emotional engagement was additionally measured by recording participants' electrodermal and cardiovascular activity continuously while watching. Analyses of variance were used to test the effects of introduction format, camera focus and their interaction. The audiovisual introduction induced a stronger blood pressure response during watching the introduction (p = 0.048, [Formula: see text]= 0.05) and the consultation part of the vignette (p = 0.051, [Formula: see text]= 0.05), when compared to the written introduction. With respect to camera focus, results revealed that the variant focusing on the patient at emotional moments evoked a higher level of electrodermal activity (p = 0.003, [Formula: see text]= 0.06), when compared to the other two variants. Furthermore, an interaction effect was shown on self-reported emotional engagement (p = 0

  15. Education and Training Packages for CAD/CAM.

    ERIC Educational Resources Information Center

    Wright, I. C.

    1986-01-01

    Discusses educational efforts in the fields of Computer Assisted Design and Manufacturing (CAD/CAM). Describes two educational training initiatives underway in the United Kingdom, one of which is a resource materials package for teachers of CAD/CAM at the undergraduate level, and the other a training course for managers of CAD/CAM systems. (TW)

  16. CAM practitioners in the Australian health workforce: an underutilized resource

    PubMed Central

    2012-01-01

    Background CAM practitioners are a valuable but underutilizes resource in Australian health care. Despite increasing public support for complementary and alternative medicine (CAM) little is known about the CAM workforce. Apart from the registered professions of chiropractic, osteopathy and Chinese medicine, accurate information about the number of CAM practitioners in the workforce has been difficult to obtain. It appears that many non-registered CAM practitioners, although highly qualified, are not working to their full capacity. Discussion Increasing public endorsement of CAM stands in contrast to the negative attitude toward the CAM workforce by some members of the medical and other health professions and by government policy makers. The marginalisation of the CAM workforce is evident in prejudicial attitudes held by some members of the medical and other health professions and its exclusion from government policy making. Inconsistent educational standards has meant that non-registered CAM practitioners, including highly qualified and competent ones, are frequently overlooked. Legitimising their contribution to the health workforce could alleviate workforce shortages and provide opportunities for redesigned job roles and new multidisciplinary teams. Priorities for better utilisation of the CAM workforce include establishing a guaranteed minimum education standard for more CAM occupation groups through national registration, providing interprofessional education that includes CAM practitioners, developing courses to upgrade CAM practitioners' professional skills in areas of indentified need, and increasing support for CAM research. Summary Marginalisation of the CAM workforce has disadvantaged those qualified and competent CAM practitioners who practise evidence-informed medicine on the basis of many years of university training. Legitimising and expanding the important contribution of CAM practitioners could alleviate projected health workforce shortages

  17. CAM practitioners in the Australian health workforce: an underutilized resource.

    PubMed

    Grace, Sandra

    2012-11-02

    CAM practitioners are a valuable but underutilizes resource in Australian health care. Despite increasing public support for complementary and alternative medicine (CAM) little is known about the CAM workforce. Apart from the registered professions of chiropractic, osteopathy and Chinese medicine, accurate information about the number of CAM practitioners in the workforce has been difficult to obtain. It appears that many non-registered CAM practitioners, although highly qualified, are not working to their full capacity. Increasing public endorsement of CAM stands in contrast to the negative attitude toward the CAM workforce by some members of the medical and other health professions and by government policy makers. The marginalisation of the CAM workforce is evident in prejudicial attitudes held by some members of the medical and other health professions and its exclusion from government policy making. Inconsistent educational standards has meant that non-registered CAM practitioners, including highly qualified and competent ones, are frequently overlooked. Legitimising their contribution to the health workforce could alleviate workforce shortages and provide opportunities for redesigned job roles and new multidisciplinary teams. Priorities for better utilisation of the CAM workforce include establishing a guaranteed minimum education standard for more CAM occupation groups through national registration, providing interprofessional education that includes CAM practitioners, developing courses to upgrade CAM practitioners' professional skills in areas of indentified need, and increasing support for CAM research. Marginalisation of the CAM workforce has disadvantaged those qualified and competent CAM practitioners who practise evidence-informed medicine on the basis of many years of university training. Legitimising and expanding the important contribution of CAM practitioners could alleviate projected health workforce shortages, particularly for the prevention and

  18. EpCAM and the biology of hepatic stem/progenitor cells

    PubMed Central

    Theise, Neil D.; Schmelzer, Eva; Boulter, Luke; Gires, Olivier; van Grunsven, Leo A.

    2014-01-01

    Epithelial cell adhesion molecule (EpCAM) is a transmembrane glycoprotein, which is frequently and highly expressed on carcinomas, tumor-initiating cells, selected tissue progenitors, and embryonic and adult stem cells. During liver development, EpCAM demonstrates a dynamic expression, since it can be detected in fetal liver, including cells of the parenchyma, whereas mature hepatocytes are devoid of EpCAM. Liver regeneration is associated with a population of EpCAM-positive cells within ductular reactions, which gradually lose the expression of EpCAM along with maturation into hepatocytes. EpCAM can be switched on and off through a wide panel of strategies to fine-tune EpCAM-dependent functional and differentiative traits. EpCAM-associated functions relate to cell–cell adhesion, proliferation, maintenance of a pluripotent state, regulation of differentiation, migration, and invasion. These functions can be conferred by the full-length protein and/or EpCAM-derived fragments, which are generated upon regulated intramembrane proteolysis. Control by EpCAM therefore not only depends on the presence of full-length EpCAM at cellular membranes but also on varying rates of the formation of EpCAM-derived fragments that have their own regulatory properties and on changes in the association of EpCAM with interaction partners. Thus spatiotemporal localization of EpCAM in immature liver progenitors, transit-amplifying cells, and mature liver cells will decisively impact the regulation of EpCAM functions and might be one of the triggers that contributes to the adaptive processes in stem/progenitor cell lineages. This review will summarize EpCAM-related molecular events and how they relate to hepatobiliary differentiation and regeneration. PMID:25477371

  19. WindCam and MSPI: two cloud and aerosol instrument concepts derived from Terra/MISR heritage

    NASA Astrophysics Data System (ADS)

    Diner, David J.; Mischna, Michael; Chipman, Russell A.; Davis, Ab; Cairns, Brian; Davies, Roger; Kahn, Ralph A.; Muller, Jan-Peter; Torres, Omar

    2008-08-01

    The Multi-angle Imaging SpectroRadiometer (MISR) has been acquiring global cloud and aerosol data from polar orbit since February 2000. MISR acquires moderately high-resolution imagery at nine view angles from nadir to 70.5°, in four visible/near-infrared spectral bands. Stereoscopic parallax, time lapse among the nine views, and the variation of radiance with angle and wavelength enable retrieval of geometric cloud and aerosol plume heights, height-resolved cloud-tracked winds, and aerosol optical depth and particle property information. Two instrument concepts based upon MISR heritage are in development. The Cloud Motion Vector Camera, or WindCam, is a simplified version comprised of a lightweight, compact, wide-angle camera to acquire multiangle stereo imagery at a single visible wavelength. A constellation of three WindCam instruments in polar Earth orbit would obtain height-resolved cloud-motion winds with daily global coverage, making it a low-cost complement to a spaceborne lidar wind measurement system. The Multiangle SpectroPolarimetric Imager (MSPI) is aimed at aerosol and cloud microphysical properties, and is a candidate for the National Research Council Decadal Survey's Aerosol-Cloud-Ecosystem (ACE) mission. MSPI combines the capabilities of MISR with those of other aerosol sensors, extending the spectral coverage to the ultraviolet and shortwave infrared and incorporating high-accuracy polarimetric imaging. Based on requirements for the nonimaging Aerosol Polarimeter Sensor on NASA's Glory mission, a degree of linear polarization uncertainty of 0.5% is specified within a subset of the MSPI bands. We are developing a polarization imaging approach using photoelastic modulators (PEMs) to accomplish this objective.

  20. ChemCam Targeted Science at Gale Crater

    NASA Astrophysics Data System (ADS)

    Wiens, R. C.; Blaney, D. L.; Clark, B. C.; Bridges, N. T.; Clegg, S. M.; Maurice, S.; Newsom, H. E.; Vaniman, D. T.; Herkenhoff, K. E.; Ollila, A. M.; Gasnault, O.; Pinet, P. C.; Dromart, G.; Barraclough, B. L.; Lasue, J.

    2011-12-01

    The MSL rover, Curiosity, uses a novel remote-sensing instrument, ChemCam, which combines laser-induced breakdown spectroscopy (LIBS) with a high resolution remote micro-imager (RMI). ChemCam uses a focused, pulsed laser beam at targets up to 7 m away to excite a light-emitting plasma. Spectral analysis identifies elements present and provides rapid semi-quantitative analyses. Repeated laser pulses remove dust and weathering coatings from rock samples to depths >0.5 mm and ~0.4 mm in diameter. The RMI, with ~20x20 mrad field of view, provides a broad-band image with 100 μm resolution. LIBS yields abundances of H, Li, Be, B, C, N, O, F, Na, Mg, Al, Si, P, Cl, K, Ca, Ti, V, Cr, Fe, Ni, Zr, Rb, Sr, As, Ba, and Pb. Interference from atmospheric constituents raises the detection limits of C, N, and O (e.g., >2% wt for C). LIBS is very sensitive to alkali and alkali earth elements, with some detection limits to ~1 ppm at close range. Conversely, LIBS is insensitive to F, Cl, S, P, and N, with detection limits of several wt. %. Pointing accuracy is ~3 mrad, however relative pointing accuracy is better, so line scans and rasters will enable analyses of targeted features to ~1 mm. At Gale Crater, determination of elements not previously analyzed in-situ, i.e., H, Li, Rb, Sr, and Ba, along with other elements will constrain aqueous, hydrothermal and vapor geochemical transport processes. Initial analyses after landing will characterize air fall dust and weathering coatings on local rocks, and profile the soil and surfacial materials including bedforms to investigate compositional differences in near-surface layers. Targets within the landing ellipse include fan and inverted channel deposits derived from the crater rim, which may contain alteration minerals produced by impact hydrothermal processes. Enigmatic deposits with bright fracture fill could represent lake sediments modified by injection of deposits from groundwater. During the drive to the Gale mound, ChemCam will

  1. Printed Educational Materials’ Impact on Tobacco Cessation Brief Interventions in CAM Practice: Patient and Practitioner Experiences

    PubMed Central

    Eaves, Emery R.; Nichter, Mark; Howerter, Amy; Floden, Lysbeth; Ritenbaugh, Cheryl; Gordon, Judith S.; Muramoto, Myra L.

    2017-01-01

    Printed educational materials (PEMs) have long demonstrated their usefulness as economical and effective media for health communication. In this article, we evaluate the impact of targeted tobacco cessation PEMS for use along with a brief intervention training designed for three types of complementary and alternative medicine (CAM) practitioners: chiropractic, acupuncture, and massage. We describe how PEMs in CAM practitioners’ offices were perceived and used by practitioners and by patients. Semistructured qualitative interviews were conducted with 53 practitioners and 38 of their patients. This analysis specifically focused on developing and distributing project-related posters and pamphlets in CAM practice. Our findings indicate that materials (1) legitimated tobacco-related expertise among CAM practitioners and tobacco-related conversations as part of routine CAM practice, (2) increased practitioners’ willingness to approach the topic of tobacco with patients, (3) created an effective way to communicate tobacco-related information and broaden the reach of brief intervention initiatives, and (4) were given to patients who were not willing to engage in direct discussion of tobacco use with practitioners. PMID:27591225

  2. Progress with the Prime Focus Spectrograph for the Subaru Telescope: a massively multiplexed optical and near-infrared fiber spectrograph

    NASA Astrophysics Data System (ADS)

    Sugai, Hajime; Tamura, Naoyuki; Karoji, Hiroshi; Shimono, Atsushi; Takato, Naruhisa; Kimura, Masahiko; Ohyama, Youichi; Ueda, Akitoshi; Aghazarian, Hrand; de Arruda, Marcio V.; Barkhouser, Robert H.; Bennett, Charles L.; Bickerton, Steve; Bozier, Alexandre; Braun, David F.; Bui, Khanh; Capocasale, Christopher M.; Carr, Michael A.; Castilho, Bruno; Chang, Yin-Chang; Chen, Hsin-Yo; Chou, Richard C. Y.; Dawson, Olivia R.; Dekany, Richard G.; Ek, Eric M.; Ellis, Richard S.; English, Robin J.; Ferrand, Didier; Ferreira, Décio; Fisher, Charles D.; Golebiowski, Mirek; Gunn, James E.; Hart, Murdock; Heckman, Timothy M.; Ho, Paul T. P.; Hope, Stephen; Hovland, Larry E.; Hsu, Shu-Fu; Hu, Yen-Sang; Huang, Pin Jie; Jaquet, Marc; Karr, Jennifer E.; Kempenaar, Jason G.; King, Matthew E.; Le Fèvre, Olivier; Le Mignant, David; Ling, Hung-Hsu; Loomis, Craig; Lupton, Robert H.; Madec, Fabrice; Mao, Peter; Marrara, Lucas S.; Ménard, Brice; Morantz, Chaz; Murayama, Hitoshi; Murray, Graham J.; de Oliveira, Antonio Cesar; de Oliveira, Claudia M.; de Oliveira, Ligia S.; Orndorff, Joe D.; de Paiva Vilaça, Rodrigo; Partos, Eamon J.; Pascal, Sandrine; Pegot-Ogier, Thomas; Reiley, Daniel J.; Riddle, Reed; Santos, Leandro; dos Santos, Jesulino B.; Schwochert, Mark A.; Seiffert, Michael D.; Smee, Stephen A.; Smith, Roger M.; Steinkraus, Ronald E.; Sodré, Laerte; Spergel, David N.; Surace, Christian; Tresse, Laurence; Vidal, Clément; Vives, Sebastien; Wang, Shiang-Yu; Wen, Chih-Yi; Wu, Amy C.; Wyse, Rosie; Yan, Chi-Hung

    2014-07-01

    The Prime Focus Spectrograph (PFS) is an optical/near-infrared multi-fiber spectrograph with 2394 science fibers, which are distributed in 1.3 degree diameter field of view at Subaru 8.2-meter telescope. The simultaneous wide wavelength coverage from 0.38 μm to 1.26 μm, with the resolving power of 3000, strengthens its ability to target three main survey programs: cosmology, Galactic archaeology, and galaxy/AGN evolution. A medium resolution mode with resolving power of 5000 for 0.71 μm to 0.89 μm also will be available by simply exchanging dispersers. PFS takes the role for the spectroscopic part of the Subaru Measurement of Images and Redshifts (SuMIRe) project, while Hyper Suprime-Cam (HSC) works on the imaging part. HSC's excellent image qualities have proven the high quality of the Wide Field Corrector (WFC), which PFS shares with HSC. The PFS collaboration has succeeded in the project Preliminary Design Review and is now in a phase of subsystem Critical Design Reviews and construction. To transform the telescope plus WFC focal ratio, a 3-mm thick broad-band coated microlens is glued to each fiber tip. The microlenses are molded glass, providing uniform lens dimensions and a variety of refractive-index selection. After successful production of mechanical and optical samples, mass production is now complete. Following careful investigations including Focal Ratio Degradation (FRD) measurements, a higher transmission fiber is selected for the longest part of cable system, while one with a better FRD performance is selected for the fiber-positioner and fiber-slit components, given the more frequent fiber movements and tightly curved structure. Each Fiber positioner consists of two stages of piezo-electric rotary motors. Its engineering model has been produced and tested. After evaluating the statistics of positioning accuracies, collision avoidance software, and interferences (if any) within/between electronics boards, mass production will commence. Fiber

  3. The CFHT MegaCam control system: new solutions based on PLCs, WorldFIP fieldbus and Java softwares

    NASA Astrophysics Data System (ADS)

    Rousse, Jean Y.; Boulade, Olivier; Charlot, Xavier; Abbon, P.; Aune, Stephan; Borgeaud, Pierre; Carton, Pierre-Henri; Carty, M.; Da Costa, J.; Deschamps, H.; Desforge, D.; Eppele, Dominique; Gallais, Pascal; Gosset, L.; Granelli, Remy; Gros, Michel; de Kat, Jean; Loiseau, Denis; Ritou, J. L.; Starzynski, Pierre; Vignal, Nicolas; Vigroux, Laurent G.

    2003-03-01

    MegaCam is a wide-field imaging camera built for the prime focus of the 3.6m Canada-France-Hawaii Telescope. This large detector has required new approaches from the hardware up to the instrument control system software. Safe control of the three sub-systems of the instrument (cryogenics, filters and shutter), measurement of the exposure time with an accuracy of 0.1%, identification of the filters and management of the internal calibration source are the major challenges that are taken up by the control system. Another challenge is to insure all these functionalities with the minimum space available on the telescope structure for the electrical hardware and a minimum number of cables to keep the highest reliability. All these requirements have been met with a control system which different elements are linked by a WorldFip fieldbus on optical fiber. The diagnosis and remote user support will be insured with an Engineering Control System station based on software developed on Internet JAVA technologies (applets, servlets) and connected on the fieldbus.

  4. Children's everyday exposure to food marketing: an objective analysis using wearable cameras.

    PubMed

    Signal, L N; Stanley, J; Smith, M; Barr, M B; Chambers, T J; Zhou, J; Duane, A; Gurrin, C; Smeaton, A F; McKerchar, C; Pearson, A L; Hoek, J; Jenkin, G L S; Ni Mhurchu, C

    2017-10-08

    Over the past three decades the global prevalence of childhood overweight and obesity has increased by 47%. Marketing of energy-dense nutrient-poor foods and beverages contributes to this worldwide increase. Previous research on food marketing to children largely uses self-report, reporting by parents, or third-party observation of children's environments, with the focus mostly on single settings and/or media. This paper reports on innovative research, Kids'Cam, in which children wore cameras to examine the frequency and nature of everyday exposure to food marketing across multiple media and settings. Kids'Cam was a cross-sectional study of 168 children (mean age 12.6 years, SD = 0.5) in Wellington, New Zealand. Each child wore a wearable camera on four consecutive days, capturing images automatically every seven seconds. Images were manually coded as either recommended (core) or not recommended (non-core) to be marketed to children by setting, marketing medium, and product category. Images in convenience stores and supermarkets were excluded as marketing examples were considered too numerous to count. On average, children were exposed to non-core food marketing 27.3 times a day (95% CI 24.8, 30.1) across all settings. This was more than twice their average exposure to core food marketing (12.3 per day, 95% CI 8.7, 17.4). Most non-core exposures occurred at home (33%), in public spaces (30%) and at school (19%). Food packaging was the predominant marketing medium (74% and 64% for core and non-core foods) followed by signs (21% and 28% for core and non-core). Sugary drinks, fast food, confectionary and snack foods were the most commonly encountered non-core foods marketed. Rates were calculated using Poisson regression. Children in this study were frequently exposed, across multiple settings, to marketing of non-core foods not recommended to be marketed to children. The study provides further evidence of the need for urgent action to reduce children's exposure to

  5. METALLICITY AND AGE OF THE STELLAR STREAM AROUND THE DISK GALAXY NGC 5907

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Laine, Seppo; Grillmair, Carl J.; Capak, Peter

    2016-09-01

    Stellar streams have become central to studies of the interaction histories of nearby galaxies. To characterize the most prominent parts of the stellar stream around the well-known nearby ( d  = 17 Mpc) edge-on disk galaxy NGC 5907, we have obtained and analyzed new, deep gri Subaru/Suprime-Cam and 3.6 μ m Spitzer /Infrared Array Camera observations. Combining the near-infrared 3.6 μ m data with visible-light images allows us to use a long wavelength baseline to estimate the metallicity and age of the stellar population along an ∼60 kpc long segment of the stream. We have fitted the stellar spectral energy distributionmore » with a single-burst stellar population synthesis model and we use it to distinguish between the proposed satellite accretion and minor/major merger formation models of the stellar stream around this galaxy. We conclude that a massive minor merger (stellar mass ratio of at least 1:8) can best account for the metallicity of −0.3 inferred along the brightest parts of the stream.« less

  6. LANL Researcher Roger Wiens Discusses ChemCam

    ScienceCinema

    Wiens, Roger

    2018-01-16

    Discussion of the ChemCam instrument on the Curiosity Rover that occurred during the NASA press conference prior to launch of the Mars Science Laboratory. The ChemCam instrument was developed by Los Alamos National Laboratory and the French Space Institute. Los Alamos National Laboratory researcher Roger Wiens discusses the instrument on this video. ChemCam uses a laser to "zap" features of the Martian landscape and then uses a spectrometer to gather information about the composition of the sample. ChemCam will help the Curiosity Rover determine whether Mars is or was habitable. The Rover is expected to touch down on the Red Planet on August 5, 2012.

  7. Lytro camera technology: theory, algorithms, performance analysis

    NASA Astrophysics Data System (ADS)

    Georgiev, Todor; Yu, Zhan; Lumsdaine, Andrew; Goma, Sergio

    2013-03-01

    The Lytro camera is the first implementation of a plenoptic camera for the consumer market. We consider it a successful example of the miniaturization aided by the increase in computational power characterizing mobile computational photography. The plenoptic camera approach to radiance capture uses a microlens array as an imaging system focused on the focal plane of the main camera lens. This paper analyzes the performance of Lytro camera from a system level perspective, considering the Lytro camera as a black box, and uses our interpretation of Lytro image data saved by the camera. We present our findings based on our interpretation of Lytro camera file structure, image calibration and image rendering; in this context, artifacts and final image resolution are discussed.

  8. Pose estimation and tracking of non-cooperative rocket bodies using Time-of-Flight cameras

    NASA Astrophysics Data System (ADS)

    Gómez Martínez, Harvey; Giorgi, Gabriele; Eissfeller, Bernd

    2017-10-01

    This paper presents a methodology for estimating the position and orientation of a rocket body in orbit - the target - undergoing a roto-translational motion, with respect to a chaser spacecraft, whose task is to match the target dynamics for a safe rendezvous. During the rendezvous maneuver the chaser employs a Time-of-Flight camera that acquires a point cloud of 3D coordinates mapping the sensed target surface. Once the system identifies the target, it initializes the chaser-to-target relative position and orientation. After initialization, a tracking procedure enables the system to sense the evolution of the target's pose between frames. The proposed algorithm is evaluated using simulated point clouds, generated with a CAD model of the Cosmos-3M upper stage and the PMD CamCube 3.0 camera specifications.

  9. A Wide-Angle Camera for the Mobile Asteroid Surface Scout (MASCOT) on Hayabusa-2

    NASA Astrophysics Data System (ADS)

    Schmitz, N.; Koncz, A.; Jaumann, R.; Hoffmann, H.; Jobs, D.; Kachlicki, J.; Michaelis, H.; Mottola, S.; Pforte, B.; Schroeder, S.; Terzer, R.; Trauthan, F.; Tschentscher, M.; Weisse, S.; Ho, T.-M.; Biele, J.; Ulamec, S.; Broll, B.; Kruselburger, A.; Perez-Prieto, L.

    2014-04-01

    JAXA's Hayabusa-2 mission, an asteroid sample return mission, is scheduled for launch in December 2014, for a rendezvous with the C-type asteroid 1999 JU3 in 2018. MASCOT, the Mobile Asteroid Surface Scout [1], is a small lander, designed to deliver ground truth for the orbiter remote measurements, support the selection of sampling sites, and provide context for the returned samples.MASCOT's main objective is to investigate the landing site's geomorphology, the internal structure, texture and composition of the regolith (dust, soil and rocks), and the thermal, mechanical, and magnetic properties of the surface. MASCOT comprises a payload of four scientific instruments: camera, radiometer, magnetometer and hyper-spectral microscope. The camera (MASCOT CAM) was designed and built by DLR's Institute of Planetary Research, together with Airbus DS Germany.

  10. LANL Researcher Roger Wiens Discusses ChemCam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wiens, Roger

    2012-02-15

    Discussion of the ChemCam instrument on the Curiosity Rover that occurred during the NASA press conference prior to launch of the Mars Science Laboratory. The ChemCam instrument was developed by Los Alamos National Laboratory and the French Space Institute. Los Alamos National Laboratory researcher Roger Wiens discusses the instrument on this video. ChemCam uses a laser to "zap" features of the Martian landscape and then uses a spectrometer to gather information about the composition of the sample. ChemCam will help the Curiosity Rover determine whether Mars is or was habitable. The Rover is expected to touch down on the Redmore » Planet on August 5, 2012.« less

  11. Therapeutic uses of the WebCam in child psychiatry.

    PubMed

    Chlebowski, Susan; Fremont, Wanda

    2011-01-01

    The authors provide examples for the use of the WebCam as a therapeutic tool in child psychiatry, discussing cases to demonstrate the application of the WebCam, which is most often used in psychiatry training programs during resident supervision and for case presentations. Six cases illustrate the use of the WebCam in individual and family therapy. The WebCam, used during individual sessions, can facilitate the development of prosocial skills. Comparing individual WebCam video sessions can help to evaluate the effectiveness of medication and progress in therapy. The WebCam has proven to be useful in psycho-education, facilitating communication, and treating children and families. The applications of this technology may include cognitive-behavioral therapy, dialectical-behavioral, and group therapy.

  12. The Role of Public Interaction with the Juno Mission: Contextual Information about the Atmosphere and Target Selection for the JunoCam

    NASA Astrophysics Data System (ADS)

    Orton, G. S.; Hansen, C. J.; Momary, T.; Bolton, S. J.

    2016-12-01

    Among the many "firsts" of the Juno mission is the open enlistment of the public in the operation of its visible camera, JunoCam. Although the scientific thrust of the Juno mission is largely focused on innovative approaches to understanding the structure and composition of the interior of Jupiter, JunoCam was added to the payload largely to function in the role of education and public outreach (E/PO). For the first time, the public will be able to engage in the discussion and choice of targets for a major NASA mission, other than two images of Jupiter's polar regions that will be made on each orbit. The discussion about which "electable" features to image is enabled by a continuously updated map of Jupiter's cloud system while Jupiter is far enough from the sun to be observable by the amateur community. This map is created bi-weekly from a set of images uploaded by a world-wide network of amateur astronomers, ranging from very devoted astrophotographers to telescope and video `hobbyists'. Juno therefore engages the world-wide amateur-astronomy community as a vast network of co-investigators, whose products stimulate conversation and global public awareness of Jupiter and Juno's investigative role. Contributed images also provide a temporal context to inform the Juno atmospheric investigation team of the state and evolution of the atmosphere. These bi-weekly maps provide the focus for ongoing discussion about various planetary features over a long time frame. Approximately two weeks before Juno's closest approach to Jupiter on each orbit, starting in mid-November of 2016, the atmospheric features that have been under discussion and will be in the field of view of the instrument nominated for voting, and the public will vote on where to point JunoCam's "elective" features (each orbit will otherwise image the north polar region and south polar region from a non-oblique viewpoint for the first time in over 40 years since the passage of Pioneer 11. The Juno mission

  13. Photographing the Earth G324: The Can Do GeoCam payload

    NASA Technical Reports Server (NTRS)

    Nicholson, James H.; Obrien, Thomas J.; Tempel, Carol A.

    1995-01-01

    The flight of the Charleston County School District Can Do Project GeoCam payload on STS-57 was the climax of a decade long endeavor to bring the promise and excitement of the space program directly into the classroom. The payload carried four cameras designed to take high resolution photographs of the Earth under the direction of children operating the first ever student control room. During the course of the flight, the students followed the Shuttle's orbital tract, satellite weather images and selected a target list that was sent up to the crew each night as part of the execute package. Targets from this list, as well as ones chosen by the crew visually, resulted in the successful collection of photographic runs at many interesting sites on three on three continents.

  14. Combustion pinhole camera system

    DOEpatents

    Witte, Arvel B.

    1984-02-21

    A pinhole camera system utilizing a sealed optical-purge assembly which provides optical access into a coal combustor or other energy conversion reactors. The camera system basically consists of a focused-purge pinhole optical port assembly, a conventional TV vidicon receiver, an external, variable density light filter which is coupled electronically to the vidicon automatic gain control (agc). The key component of this system is the focused-purge pinhole optical port assembly which utilizes a purging inert gas to keep debris from entering the port and a lens arrangement which transfers the pinhole to the outside of the port assembly. One additional feature of the port assembly is that it is not flush with the interior of the combustor.

  15. Complementary and Alternative Medicine (CAM) use by Malaysian oncology patients.

    PubMed

    Farooqui, Maryam; Hassali, Mohamed Azmi; Abdul Shatar, Aishah Knight; Shafie, Asrul Akmal; Seang, Tan Boon; Farooqui, Muhammad Aslam

    2012-05-01

    The current study sought to evaluate Malaysian oncology patients' decision making about the use of Complementary and Alternative Medicine (CAM) for the management of their care. Patients were interviewed across three major Malaysian ethnic groups, Malay, Chinese and Indian. Thematic content analysis identified four central themes: Conceptualizing CAM, the decision making process; rationale given for selecting or rejecting CAM and barriers to CAM use. Participants generally used the term 'traditional medicine', referred to locally as 'ubat kampung', meaning medicine derived from 'local traditions'. Mixed reactions were shown concerning the effectiveness of CAM to cure cancer and the slow progression of CAM results and treatment costs were cited as major barriers to CAM use. Concerns regarding safety and efficacy of CAM in ameliorating cancer as well as potential interactions with conventional therapies highlighted the importance of patients' knowledge about cancer treatments. Copyright © 2011 Elsevier Ltd. All rights reserved.

  16. CAM controlled retractable door latch

    NASA Technical Reports Server (NTRS)

    Carsley, R. B. (Inventor)

    1982-01-01

    A latching mechanism in which there is linear movement and rotational movement is described. The umbilical doors of the space shuttle orbiter are required to be open during vehicle launch. After the external tank is released, the doors are closed. Presently, the device for maintaining the doors in an open position is mounted on the external tank and therefore has a single mission life. The latching mechanism of the invention is mounted in the orbiter and therefore is returned and has multimission capability. The latching mechanism is comprised of a pair of concentric nested, cylindrical cams and motors to actuate the cams, and latch pin all contained within a cover mounted on a support bracket carried by the substructure. A shaft having a latch pin is mounted inside the inner cylindrical cam.

  17. STARL -- a Program to Correct CCD Image Defects

    NASA Astrophysics Data System (ADS)

    Narbutis, D.; Vanagas, R.; Vansevičius, V.

    We present a program tool, STARL, designed for automatic detection and correction of various defects in CCD images. It uses genetic algorithm for deblending and restoring of overlapping saturated stars in crowded stellar fields. Using Subaru Telescope Suprime-Cam images we demonstrate that the program can be implemented in the wide-field survey data processing pipelines for production of high quality color mosaics. The source code and examples are available at the STARL website.

  18. Depth-of-Interaction Compensation Using a Focused-Cut Scintillator for a Pinhole Gamma Camera.

    PubMed

    Alhassen, Fares; Kudrolli, Haris; Singh, Bipin; Kim, Sangtaek; Seo, Youngho; Gould, Robert G; Nagarkar, Vivek V

    2011-06-01

    Preclinical SPECT offers a powerful means to understand the molecular pathways of drug interactions in animal models by discovering and testing new pharmaceuticals and therapies for potential clinical applications. A combination of high spatial resolution and sensitivity are required in order to map radiotracer uptake within small animals. Pinhole collimators have been investigated, as they offer high resolution by means of image magnification. One of the limitations of pinhole geometries is that increased magnification causes some rays to travel through the detection scintillator at steep angles, introducing parallax errors due to variable depth-of-interaction in scintillator material, especially towards the edges of the detector field of view. These parallax errors ultimately limit the resolution of pinhole preclinical SPECT systems, especially for higher energy isotopes that can easily penetrate through millimeters of scintillator material. A pixellated, focused-cut (FC) scintillator, with its pixels laser-cut so that they are collinear with incoming rays, can potentially compensate for these parallax errors and thus improve the system resolution. We performed the first experimental evaluation of a newly developed focused-cut scintillator. We scanned a Tc-99m source across the field of view of pinhole gamma camera with a continuous scintillator, a conventional "straight-cut" (SC) pixellated scintillator, and a focused-cut scintillator, each coupled to an electron-multiplying charge coupled device (EMCCD) detector by a fiber-optic taper, and compared the measured full-width half-maximum (FWHM) values. We show that the FWHMs of the focused-cut scintillator projections are comparable to the FWHMs of the thinner SC scintillator, indicating the effectiveness of the focused-cut scintillator in compensating parallax errors.

  19. Depth-of-Interaction Compensation Using a Focused-Cut Scintillator for a Pinhole Gamma Camera

    PubMed Central

    Alhassen, Fares; Kudrolli, Haris; Singh, Bipin; Kim, Sangtaek; Seo, Youngho; Gould, Robert G.; Nagarkar, Vivek V.

    2011-01-01

    Preclinical SPECT offers a powerful means to understand the molecular pathways of drug interactions in animal models by discovering and testing new pharmaceuticals and therapies for potential clinical applications. A combination of high spatial resolution and sensitivity are required in order to map radiotracer uptake within small animals. Pinhole collimators have been investigated, as they offer high resolution by means of image magnification. One of the limitations of pinhole geometries is that increased magnification causes some rays to travel through the detection scintillator at steep angles, introducing parallax errors due to variable depth-of-interaction in scintillator material, especially towards the edges of the detector field of view. These parallax errors ultimately limit the resolution of pinhole preclinical SPECT systems, especially for higher energy isotopes that can easily penetrate through millimeters of scintillator material. A pixellated, focused-cut (FC) scintillator, with its pixels laser-cut so that they are collinear with incoming rays, can potentially compensate for these parallax errors and thus improve the system resolution. We performed the first experimental evaluation of a newly developed focused-cut scintillator. We scanned a Tc-99m source across the field of view of pinhole gamma camera with a continuous scintillator, a conventional “straight-cut” (SC) pixellated scintillator, and a focused-cut scintillator, each coupled to an electron-multiplying charge coupled device (EMCCD) detector by a fiber-optic taper, and compared the measured full-width half-maximum (FWHM) values. We show that the FWHMs of the focused-cut scintillator projections are comparable to the FWHMs of the thinner SC scintillator, indicating the effectiveness of the focused-cut scintillator in compensating parallax errors. PMID:21731108

  20. Depth-of-Interaction Compensation Using a Focused-Cut Scintillator for a Pinhole Gamma Camera

    NASA Astrophysics Data System (ADS)

    Alhassen, Fares; Kudrolli, Haris; Singh, Bipin; Kim, Sangtaek; Seo, Youngho; Gould, Robert G.; Nagarkar, Vivek V.

    2011-06-01

    Preclinical SPECT offers a powerful means to understand the molecular pathways of drug interactions in animal models by discovering and testing new pharmaceuticals and therapies for potential clinical applications. A combination of high spatial resolution and sensitivity are required in order to map radiotracer uptake within small animals. Pinhole collimators have been investigated, as they offer high resolution by means of image magnification. One of the limitations of pinhole geometries is that increased magnification causes some rays to travel through the detection scintillator at steep angles, introducing parallax errors due to variable depth-of-interaction in scintillator material, especially towards the edges of the detector field of view. These parallax errors ultimately limit the resolution of pinhole preclinical SPECT systems, especially for higher energy isotopes that can easily penetrate through millimeters of scintillator material. A pixellated, focused-cut (FC) scintillator, with its pixels laser-cut so that they are collinear with incoming rays, can potentially compensate for these parallax errors and thus improve the system resolution. We performed the first experimental evaluation of a newly developed focused-cut scintillator. We scanned a Tc-99 m source across the field of view of pinhole gamma camera with a continuous scintillator, a conventional “straight-cut” (SC) pixellated scintillator, and a focused-cut scintillator, each coupled to an electron-multiplying charge coupled device (EMCCD) detector by a fiber-optic taper, and compared the measured full-width half-maximum (FWHM) values. We show that the FWHMs of the focused-cut scintillator projections are comparable to the FWHMs of the thinner SC scintillator, indicating the effectiveness of the focused-cut scintillator in compensating parallax errors.

  1. Evaluating the feasibility of measuring travel to school using a wearable camera.

    PubMed

    Kelly, Paul; Doherty, Aiden R; Hamilton, Alex; Matthews, Anne; Batterham, Alan M; Nelson, Michael; Foster, Charlie; Cowburn, Gill

    2012-11-01

    The school journey is often studied in relation to health outcomes in children and adolescents. Self-report is the most common measurement tool. To investigate the error on self-reported journey duration in adolescents, using a wearable digital camera (Microsoft SenseCam). During March-May 2011, participants (n=17; aged 13-15 years) from four schools wore wearable cameras to and from school for 1 week. The device automatically records time-stamped, first-person point-of-view images, without any action from the wearer. Participants also completed a researcher-administered self-report travel survey over the same period. Analysis took place in November 2011. Within- and between-subjects correlation coefficients and Bland-Altman 95% limits of agreement were derived, accounting for the multiple observations per individual. Self-report data were collected for 150 journey stages and SenseCam data for 135 (90%) of these. The within-subjects correlation coefficient for journey duration was 0.89 (95% CI=0.84, 0.93). The between-subjects correlation coefficient was 0.92 (95% CI=0.79, 0.97). The mean difference (bias) between methods at the whole sample level was small (10 seconds per journey, 95% CI= -33, 53). The wide limits of agreement (± 501 seconds, 95% CI= -491, 511) reveal large random error. Compared to direct observation from images, self-reported journey duration is accurate at the mean group level but imprecise at the level of the individual participant. Copyright © 2012 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  2. Changing the Production Pipeline - Use of Oblique Aerial Cameras for Mapping Purposes

    NASA Astrophysics Data System (ADS)

    Moe, K.; Toschi, I.; Poli, D.; Lago, F.; Schreiner, C.; Legat, K.; Remondino, F.

    2016-06-01

    This paper discusses the potential of current photogrammetric multi-head oblique cameras, such as UltraCam Osprey, to improve the efficiency of standard photogrammetric methods for surveying applications like inventory surveys and topographic mapping for public administrations or private customers. In 2015, Terra Messflug (TM), a subsidiary of Vermessung AVT ZT GmbH (Imst, Austria), has flown a number of urban areas in Austria, Czech Republic and Hungary with an UltraCam Osprey Prime multi-head camera system from Vexcel Imaging. In collaboration with FBK Trento (Italy), the data acquired at Imst (a small town in Tyrol, Austria) were analysed and processed to extract precise 3D topographic information. The Imst block comprises 780 images and covers an area of approx. 4.5 km by 1.5 km. Ground truth data is provided in the form of 6 GCPs and several check points surveyed with RTK GNSS. Besides, 3D building data obtained by photogrammetric stereo plotting from a 5 cm nadir flight and a LiDAR point cloud with 10 to 20 measurements per m² are available as reference data or for comparison. The photogrammetric workflow, from flight planning to Dense Image Matching (DIM) and 3D building extraction, is described together with the achieved accuracy. For each step, the differences and innovation with respect to standard photogrammetric procedures based on nadir images are shown, including high overlaps, improved vertical accuracy, and visibility of areas masked in the standard vertical views. Finally the advantages of using oblique images for inventory surveys are demonstrated.

  3. Chiropractic and CAM utilization: a descriptive review.

    PubMed

    Lawrence, Dana J; Meeker, William C

    2007-01-22

    To conduct a descriptive review of the scientific literature examining use rates of modalities and procedures used by CAM clinicians to manage chronic LBP and other conditions A literature of PubMed and MANTIS was performed using the key terms Chiropractic; Low Back Pain; Utilization Rate; Use Rate; Complementary and Alternative Medicine; and Health Services in various combinations. A total of 137 papers were selected, based upon including information about chiropractic utilization, CAM utilization and low back pain and other conditions. Information was extracted from each paper addressing use of chiropractic and CAM, and is summarized in tabular form. Thematic analysis of the paper topics indicated that there were 5 functional areas covered by the literature: back pain papers, general chiropractic papers, insurance-related papers, general CAM-related papers; and worker's compensation papers. Studies looking at chiropractic utilization demonstrate that the rates vary, but generally fall into a range from around 6% to 12% of the population, most of whom seek chiropractic care for low back pain and not for organic disease or visceral dysfunction. CAM is itself used by people suffering from a variety of conditions, though it is often used not as a primary intervention, but rather as an additional form of care. CAM and chiropractic often offer lower costs for comparable results compared to conventional medicine.

  4. Self-latching eccentric cam for dual stroke compressor or pump

    DOEpatents

    Sisk, Francis J.

    1985-01-01

    For a dual capacity refrigerant compressor of the type which has an eccentric cam rotatable on a crankpin between two opposite positions which changes the total eccentricity of the crankpin and cam so as to obtain two different stroke lengths, the rotation of the cam on the crankpin being effected by a reversal of motor operation, the cam moves through an angle of about 270.degree. around the crankpin so that a centrifugal force torque tending to hold the cam in place is available at least in the reduced stroke length position of the cam, and by providing lightening cavities and eccentric weightings, the center of mass 74 of the cam can be shifted to obtain the centrifugal torque in the proper direction at both the maximum and reduced stroke positions.

  5. Self-latching eccentric cam for dual stroke compressor or pump

    DOEpatents

    Sisk, F.J.

    1985-01-22

    For a dual capacity refrigerant compressor of the type which has an eccentric cam rotatable on a crankpin between two opposite positions which changes the total eccentricity of the crankpin and cam so as to obtain two different stroke lengths, the rotation of the cam on the crankpin being effected by a reversal of motor operation, the cam moves through an angle of about 270[degree] around the crankpin so that a centrifugal force torque tending to hold the cam in place is available at least in the reduced stroke length position of the cam, and by providing lightening cavities and eccentric weightings, the center of mass of the cam can be shifted to obtain the centrifugal torque in the proper direction at both the maximum and reduced stroke positions. 7 figs.

  6. An overview of CAM: components and clinical uses.

    PubMed

    Kiefer, David; Pitluk, Jessica; Klunk, Kathryn

    2009-01-01

    Complementary and alternative medicine (CAM), more recently known as integrative health or integrative medicine, is a diverse field comprising numerous treatments and practitioners of various levels of training. This review defines several of the main CAM modalities and reviews some of the research relevant to their clinical application. The goal is to provide healthcare providers with a basic understanding of CAM to start the incorporation of proven treatments into their clinical practice as well as guide them to working with CAM providers; ultimately, such knowledge is a fundamental part of a collaborative approach to optimal patient health and wellness.

  7. CAD/CAM produces dentures with improved fit.

    PubMed

    Steinmassl, Otto; Dumfahrt, Herbert; Grunert, Ingrid; Steinmassl, Patricia-Anca

    2018-02-22

    Resin polymerisation shrinkage reduces the congruence of the denture base with denture-bearing tissues and thereby decreases the retention of conventionally fabricated dentures. CAD/CAM denture manufacturing is a subtractive process, and polymerisation shrinkage is not an issue anymore. Therefore, CAD/CAM dentures are assumed to show a higher denture base congruence than conventionally fabricated dentures. It has been the aim of this study to test this hypothesis. CAD/CAM dentures provided by four different manufacturers (AvaDent, Merz Dental, Whole You, Wieland/Ivoclar) were generated from ten different master casts. Ten conventional dentures (pack and press, long-term heat polymerisation) made from the same master casts served as control group. The master casts and all denture bases were scanned and matched digitally. The absolute incongruences were measured using a 2-mm mesh. Conventionally fabricated dentures showed a mean deviation of 0.105 mm, SD = 0.019 from the master cast. All CAD/CAM dentures showed lower mean incongruences. From all CAD/CAM dentures, AvaDent Digital Dentures showed the highest congruence with the master cast surface with a mean deviation of 0.058 mm, SD = 0.005. Wieland Digital Dentures showed a mean deviation of 0.068 mm, SD = 0.005, Whole You Nexteeth prostheses showed a mean deviation of 0.074 mm, SD = 0.011 and Baltic Denture System prostheses showed a mean deviation of 0.086 mm, SD = 0.012. CAD/CAM produces dentures with better fit than conventional dentures. The present study explains the clinically observed enhanced retention and lower traumatic ulcer-frequency in CAD/CAM dentures.

  8. Nonholonomic camera-space manipulation using cameras mounted on a mobile base

    NASA Astrophysics Data System (ADS)

    Goodwine, Bill; Seelinger, Michael J.; Skaar, Steven B.; Ma, Qun

    1998-10-01

    The body of work called `Camera Space Manipulation' is an effective and proven method of robotic control. Essentially, this technique identifies and refines the input-output relationship of the plant using estimation methods and drives the plant open-loop to its target state. 3D `success' of the desired motion, i.e., the end effector of the manipulator engages a target at a particular location with a particular orientation, is guaranteed when there is camera space success in two cameras which are adequately separated. Very accurate, sub-pixel positioning of a robotic end effector is possible using this method. To date, however, most efforts in this area have primarily considered holonomic systems. This work addresses the problem of nonholonomic camera space manipulation by considering the problem of a nonholonomic robot with two cameras and a holonomic manipulator on board the nonholonomic platform. While perhaps not as common in robotics, such a combination of holonomic and nonholonomic degrees of freedom are ubiquitous in industry: fork lifts and earth moving equipment are common examples of a nonholonomic system with an on-board holonomic actuator. The nonholonomic nature of the system makes the automation problem more difficult due to a variety of reasons; in particular, the target location is not fixed in the image planes, as it is for holonomic systems (since the cameras are attached to a moving platform), and there is a fundamental `path dependent' nature of nonholonomic kinematics. This work focuses on the sensor space or camera-space-based control laws necessary for effectively implementing an autonomous system of this type.

  9. Combustion pinhole-camera system

    DOEpatents

    Witte, A.B.

    1982-05-19

    A pinhole camera system is described utilizing a sealed optical-purge assembly which provides optical access into a coal combustor or other energy conversion reactors. The camera system basically consists of a focused-purge pinhole optical port assembly, a conventional TV vidicon receiver, an external, variable density light filter which is coupled electronically to the vidicon automatic gain control (agc). The key component of this system is the focused-purge pinhole optical port assembly which utilizes a purging inert gas to keep debris from entering the port and a lens arrangement which transfers the pinhole to the outside of the port assembly. One additional feature of the port assembly is that it is not flush with the interior of the combustor.

  10. Combustion pinhole camera system

    DOEpatents

    Witte, A.B.

    1984-02-21

    A pinhole camera system is described utilizing a sealed optical-purge assembly which provides optical access into a coal combustor or other energy conversion reactors. The camera system basically consists of a focused-purge pinhole optical port assembly, a conventional TV vidicon receiver, an external, variable density light filter which is coupled electronically to the vidicon automatic gain control (agc). The key component of this system is the focused-purge pinhole optical port assembly which utilizes a purging inert gas to keep debris from entering the port and a lens arrangement which transfers the pinhole to the outside of the port assembly. One additional feature of the port assembly is that it is not flush with the interior of the combustor. 2 figs.

  11. Electronographic cameras for space astronomy.

    NASA Technical Reports Server (NTRS)

    Carruthers, G. R.; Opal, C. B.

    1972-01-01

    Magnetically-focused electronographic cameras have been under development at the Naval Research Laboratory for use in far-ultraviolet imagery and spectrography, primarily in astronomical and optical-geophysical observations from sounding rockets and space vehicles. Most of this work has been with cameras incorporating internal optics of the Schmidt or wide-field all-reflecting types. More recently, we have begun development of electronographic spectrographs incorporating an internal concave grating, operating at normal or grazing incidence. We also are developing electronographic image tubes of the conventional end-window-photo-cathode type, for far-ultraviolet imagery at the focus of a large space telescope, with image formats up to 120 mm in diameter.

  12. Development of biostereometric experiments. [stereometric camera system

    NASA Technical Reports Server (NTRS)

    Herron, R. E.

    1978-01-01

    The stereometric camera was designed for close-range techniques in biostereometrics. The camera focusing distance of 360 mm to infinity covers a broad field of close-range photogrammetry. The design provides for a separate unit for the lens system and interchangeable backs on the camera for the use of single frame film exposure, roll-type film cassettes, or glass plates. The system incorporates the use of a surface contrast optical projector.

  13. Genomic analyses of the CAM plant pineapple.

    PubMed

    Zhang, Jisen; Liu, Juan; Ming, Ray

    2014-07-01

    The innovation of crassulacean acid metabolism (CAM) photosynthesis in arid and/or low CO2 conditions is a remarkable case of adaptation in flowering plants. As the most important crop that utilizes CAM photosynthesis, the genetic and genomic resources of pineapple have been developed over many years. Genetic diversity studies using various types of DNA markers led to the reclassification of the two genera Ananas and Pseudananas and nine species into one genus Ananas and two species, A. comosus and A. macrodontes with five botanical varieties in A. comosus. Five genetic maps have been constructed using F1 or F2 populations, and high-density genetic maps generated by genotype sequencing are essential resources for sequencing and assembling the pineapple genome and for marker-assisted selection. There are abundant expression sequence tag resources but limited genomic sequences in pineapple. Genes involved in the CAM pathway has been analysed in several CAM plants but only a few of them are from pineapple. A reference genome of pineapple is being generated and will accelerate genetic and genomic research in this major CAM crop. This reference genome of pineapple provides the foundation for studying the origin and regulatory mechanism of CAM photosynthesis, and the opportunity to evaluate the classification of Ananas species and botanical cultivars. © The Author 2014. Published by Oxford University Press on behalf of the Society for Experimental Biology. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  14. The sluggs survey: HST/ACS mosaic imaging of the NGC 3115 globular cluster system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jennings, Zachary G.; Romanowsky, Aaron J.; Brodie, Jean P.

    We present Hubble Space Telescope/Advanced Camera for Surveys (HST/ACS) g and z photometry and half-light radii R {sub h} measurements of 360 globular cluster (GC) candidates around the nearby S0 galaxy NGC 3115. We also include Subaru/Suprime-Cam g, r, and i photometry of 421 additional candidates. The well-established color bimodality of the GC system is obvious in the HST/ACS photometry. We find evidence for a 'blue tilt' in the blue GC subpopulation, wherein the GCs in the blue subpopulation get redder as luminosity increases, indicative of a mass-metallicity relationship. We find a color gradient in both the red and bluemore » subpopulations, with each group of clusters becoming bluer at larger distances from NGC 3115. The gradient is of similar strength in both subpopulations, but is monotonic and more significant for the blue clusters. On average, the blue clusters have ∼10% larger R {sub h} than the red clusters. This average difference is less than is typically observed for early-type galaxies but does match that measured in the literature for the Sombrero Galaxy (M104), suggesting that morphology and inclination may affect the measured size difference between the red and blue clusters. However, the scatter on the R {sub h} measurements is large. We also identify 31 clusters more extended than typical GCs, which we term ultra-compact dwarf (UCD) candidates. Many of these objects are actually considerably fainter than typical UCDs. While it is likely that a significant number will be background contaminants, six of these UCD candidates are spectroscopically confirmed as NGC 3115 members. To explore the prevalence of low-mass X-ray binaries in the GC system, we match our ACS and Suprime-Cam detections to corresponding Chandra X-ray sources. We identify 45 X-ray-GC matches: 16 among the blue subpopulation and 29 among the red subpopulation. These X-ray/GC coincidence fractions are larger than is typical for most GC systems, probably due to the increased

  15. Automatically assisting human memory: a SenseCam browser.

    PubMed

    Doherty, Aiden R; Moulin, Chris J A; Smeaton, Alan F

    2011-10-01

    SenseCams have many potential applications as tools for lifelogging, including the possibility of use as a memory rehabilitation tool. Given that a SenseCam can log hundreds of thousands of images per year, it is critical that these be presented to the viewer in a manner that supports the aims of memory rehabilitation. In this article we report a software browser constructed with the aim of using the characteristics of memory to organise SenseCam images into a form that makes the wealth of information stored on SenseCam more accessible. To enable a large amount of visual information to be easily and quickly assimilated by a user, we apply a series of automatic content analysis techniques to structure the images into "events", suggest their relative importance, and select representative images for each. This minimises effort when browsing and searching. We provide anecdotes on use of such a system and emphasise the need for SenseCam images to be meaningfully sorted using such a browser.

  16. Concerns of Hydrothermal Degradation in CAD/CAM Zirconia

    PubMed Central

    Kim, J.-W.; Covel, N.S.; Guess, P.C.; Rekow, E.D.; Zhang, Y.

    2010-01-01

    Zirconia-based restorations are widely used in prosthetic dentistry; however, their susceptibility to hydrothermal degradation remains elusive. We hypothesized that CAD/CAM machining and subsequent surface treatments, i.e., grinding and/or grit-blasting, have marked effects on the hydrothermal degradation behavior of Y-TZP. CAD/CAM-machined Y-TZP plates (0.5 mm thick), both with and without subsequent grinding with various grit sizes or grit-blasting with airborne alumina particles, were subjected to accelerated aging tests in a steam autoclave. Results showed that the CAD/CAM-machined surfaces initially exhibited superior hydrothermal degradation resistance, but deteriorated at a faster rate upon prolonged autoclave treatment compared with ground and grit-blasted surfaces. The accelerated hydrothermal degradation of CAD/CAM surfaces is attributed to the CAD/CAM machining damage and the absence of surface compressive stresses in the fully sintered material. Clinical relevance for surface treatments of zirconia frameworks in terms of hydrothermal and structural stabilities is addressed. PMID:19966039

  17. Fringing in MonoCam Y4 filter images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brooks, J.; Fisher-Levine, M.; Nomerotski, A.

    Here, we study the fringing patterns observed in MonoCam, a camera with a single Large Synoptic Survey Telescope (LSST) CCD sensor. Images were taken at the U.S. Naval Observatory in Flagstaff, Arizona (NOFS) employing its 1.3 m telescope and an LSST y4 filter. Fringing occurs due to the reflection of infrared light (700 nm or larger) from the bottom surface of the CCD which constructively or destructively interferes with the incident light to produce a net "fringe" pattern which is superimposed on all images taken. Emission lines from the atmosphere, dominated by hydroxyl (OH) spectra, can change in their relativemore » intensities as the night goes on, producing different fringe patterns in the images taken. We found through several methods that the general shape of the fringe patterns remained constant, though with slight changes in the amplitude and phase of the fringes. Lastly, we also found that a superposition of fringes from two monochromatic lines taken in the lab offered a reasonable description of the sky data.« less

  18. Fringing in MonoCam Y4 filter images

    DOE PAGES

    Brooks, J.; Fisher-Levine, M.; Nomerotski, A.

    2017-05-05

    Here, we study the fringing patterns observed in MonoCam, a camera with a single Large Synoptic Survey Telescope (LSST) CCD sensor. Images were taken at the U.S. Naval Observatory in Flagstaff, Arizona (NOFS) employing its 1.3 m telescope and an LSST y4 filter. Fringing occurs due to the reflection of infrared light (700 nm or larger) from the bottom surface of the CCD which constructively or destructively interferes with the incident light to produce a net "fringe" pattern which is superimposed on all images taken. Emission lines from the atmosphere, dominated by hydroxyl (OH) spectra, can change in their relativemore » intensities as the night goes on, producing different fringe patterns in the images taken. We found through several methods that the general shape of the fringe patterns remained constant, though with slight changes in the amplitude and phase of the fringes. Lastly, we also found that a superposition of fringes from two monochromatic lines taken in the lab offered a reasonable description of the sky data.« less

  19. Diagenetic Features Analyzed by ChemCam/Curiosity at Pahrump Hills, Gale Crater, Mars

    NASA Technical Reports Server (NTRS)

    Nachon, M.; Mangold, N.; Cousin, A.; Forni, O.; Anderson, R. B.; Blank, J. G.; Calef, F.; Clegg, S.; Fabre, C.; Fisk, M.; hide

    2015-01-01

    Onboard the Mars Science Laboratory (MSL) Curiosity rover, the ChemCam instrument consists of : (1) a Laser-Induced Breakdown Spectrometer (LIBS) for elemental analysis of targets and (2) a Remote Micro Imager (RMI), which provides imaging context for the LIBS. The LIBS/ChemCam performs analysis typically of spot sizes 350-550 micrometers in diameter, up to 7 meters from the rover. Within Gale crater, Curiosity traveled from Bradbury Landing toward the base of Mount Sharp, reaching Pahrump Hills outcrop circa sol 750. This region, as seen from orbit, represents the first exposures of lower Mount Sharp. In this abstract we focus on two types of features present within the Pahrump Hills outcrop: concretion features and light-toned veins.

  20. Online Tobacco Cessation Training and Competency Assessment for Complementary and Alternative Medicine (CAM) Practitioners: Protocol for the CAM Reach Web Study

    PubMed Central

    Howerter, Amy; Eaves, Emery R; Hall, John R; Buller, David B; Gordon, Judith S

    2016-01-01

    Background Complementary and alternative medicine (CAM) practitioners, such as chiropractors, acupuncturists, and massage therapists, are a growing presence in the US health care landscape and already provide health and wellness care to significant numbers of patients who use tobacco. For decades, conventional biomedical practitioners have received training to provide evidence-based tobacco cessation brief interventions (BIs) and referrals to cessation services as part of routine clinical care, whereas CAM practitioners have been largely overlooked for BI training. Web-based training has clear potential to meet large-scale training dissemination needs. However, despite the exploding use of Web-based training for health professionals, Web-based evaluation of clinical skills competency remains underdeveloped. Objective In pursuit of a long-term goal of helping CAM practitioners integrate evidence-based practices from US Public Health Service Tobacco Dependence Treatment Guideline into routine clinical care, this pilot protocol aims to develop and test a Web-based tobacco cessation training program tailored for CAM practitioners. Methods In preparation for a larger trial to examine the effect of training on CAM practitioner clinical practice behaviors around tobacco cessation, this developmental study will (1) adapt an existing in-person tobacco cessation BI training program that is specifically tailored for CAM therapists for delivery via the Internet; (2) develop a novel, Web-based tool to assess CAM practitioner competence in tobacco cessation BI skills, and conduct a pilot validation study comparing the competency assessment tool to live video role plays with a standardized patient; (3) pilot test the Web-based training with 120 CAM practitioners (40 acupuncturists, 40 chiropractors, 40 massage therapists) for usability, accessibility, acceptability, and effects on practitioner knowledge, self-efficacy, and competency with tobacco cessation; and (4) conduct

  1. Complementary and alternative medicine (CAM) in obstetrics and gynaecology: a survey of office-based obstetricians and gynaecologists regarding attitudes towards CAM, its provision and cooperation with other CAM providers in the state of Hesse, Germany.

    PubMed

    Münstedt, K; Maisch, M; Tinneberg, H R; Hübner, J

    2014-12-01

    Whereas we have some information on complementary medicine in the field of oncology, little is known about complementary medicine in the field of obstetrics and gynaecology especially outside of hospitals. All office-based obstetricians and gynaecologists in the state of Hesse, Germany, were contacted and asked to fill in an assessment form regarding cooperation in the field of complementary and alternative medicine (CAM), as well as the perceived efficacy of various CAM methods for a number of pathological conditions in the field of obstetrics and gynaecology. It was found that more than half of Hessian office-based obstetricians and gynaecologists had existing cooperation regarding CAM, especially with colleagues, but also midwives, pharmacists, physiotherapists, and health practitioners. The probability of cooperation was significantly inversely associated with age. It was found that the probability for advising CAM differed between various health problems. The following CAM methods were considered reasonable for the treatment of different conditions: phytotherapy for climacteric complaints and premenstrual syndrome; homoeopathy for puerperal problems; acupuncture and traditional Chinese medicine for complaints during pregnancy; and dietary supplements for the side effects of cancer therapy. The analysis shows that there is much cooperation in the field of CAM. Comparison between physicians' perceived efficacy of CAM methods and objective findings shows that there is a need for the provision of valid information in the field.

  2. Continuous monitoring of Hawaiian volcanoes using thermal cameras

    NASA Astrophysics Data System (ADS)

    Patrick, M. R.; Orr, T. R.; Antolik, L.; Lee, R.; Kamibayashi, K.

    2012-12-01

    Matlab, includes automated measurements of lava lake level and surface crust velocity, tracking temperatures and hot areas in real-time, and alerts which notify users of notable temperature increases via text messaging. Lastly, real-time image and processed data display, which is vital for effective use of the images at the observatory, is done through a custom Web-based environment . Near real-time webcam images are displayed for the public at hvo.wr.usgs.gov/cams. Thermal cameras are costly, but have proven to be an extremely effective monitoring and research tool at the Hawaiian Volcano Observatory.

  3. Loss of membranous Ep-CAM in budding colorectal carcinoma cells.

    PubMed

    Gosens, Marleen J E M; van Kempen, Léon C L; van de Velde, Cornelis J H; van Krieken, J Han J M; Nagtegaal, Iris D

    2007-02-01

    Tumor budding is a histological feature that reflects loss of adhesion of tumor cells and is associated with locoregional metastasis of colorectal carcinoma. Although nuclear localization of beta-catenin is associated with tumor budding, the molecular mechanism remains largely elusive. In this study, we hypothesize that the epithelial cell adhesion molecule (Ep-CAM) is involved in tumor budding. In order to address this question, we performed immunohistochemistry on Ep-CAM using three different antibodies (monoclonal antibodies Ber-ep4 and 311-1K1 and a polyclonal antibody) and a double staining on beta-catenin and Ep-CAM. In addition, Ep-CAM mRNA was monitored with mRNA in situ hybridization. Subsequently, we determined the effect of Ep-CAM staining patterns on tumor spread in rectal cancer. In contrast to the tumor mass, budding cells of colorectal carcinoma displayed lack of membranous but highly increased cytoplasmic Ep-CAM staining and nuclear translocation of beta-catenin. mRNA in situ hybridization suggested no differences in Ep-CAM expression between the invasive front and the tumor mass. Importantly, reduced Ep-CAM staining at the invasive margin of rectal tumor specimens (n=133) correlated significantly with tumor budding, tumor grade and an increased risk of local recurrence (P=0.001, P=0.04 and P=0.03, respectively). These data demonstrate abnormal processing of Ep-CAM at the invasive margin of colorectal carcinomas. Our observations indicate that loss of membranous Ep-CAM is associated with nuclear beta-catenin localization and suggest that this contributes to reduced cell-cell adhesions, increased migratory potential and tumor budding.

  4. Three New Z Cam Stars (Abstract)

    NASA Astrophysics Data System (ADS)

    Simonsen, M.

    2016-12-01

    (Abstract only) I will present the evidence and discovery stories of three cataclysmic variables who appear to be members of the Z Cam class of dwarf novae. One discovered by a lone visual observer and his unwavering patience and persistence, one through the directed effort of the ongoing Z CamPaign and one via survey data from the Gaia satellite.

  5. An open CAM system for dentistry on the basis of China-made 5-axis simultaneous contouring CNC machine tool and industrial CAM software.

    PubMed

    Lu, Li; Liu, Shusheng; Shi, Shenggen; Yang, Jianzhong

    2011-10-01

    China-made 5-axis simultaneous contouring CNC machine tool and domestically developed industrial computer-aided manufacture (CAM) technology were used for full crown fabrication and measurement of crown accuracy, with an attempt to establish an open CAM system for dental processing and to promote the introduction of domestic dental computer-aided design (CAD)/CAM system. Commercially available scanning equipment was used to make a basic digital tooth model after preparation of crown, and CAD software that comes with the scanning device was employed to design the crown by using domestic industrial CAM software to process the crown data in order to generate a solid model for machining purpose, and then China-made 5-axis simultaneous contouring CNC machine tool was used to complete machining of the whole crown and the internal accuracy of the crown internal was measured by using 3D-MicroCT. The results showed that China-made 5-axis simultaneous contouring CNC machine tool in combination with domestic industrial CAM technology can be used for crown making and the crown was well positioned in die. The internal accuracy was successfully measured by using 3D-MicroCT. It is concluded that an open CAM system for dentistry on the basis of China-made 5-axis simultaneous contouring CNC machine tool and domestic industrial CAM software has been established, and development of the system will promote the introduction of domestically-produced dental CAD/CAM system.

  6. Electronic still camera

    NASA Astrophysics Data System (ADS)

    Holland, S. Douglas

    1992-09-01

    A handheld, programmable, digital camera is disclosed that supports a variety of sensors and has program control over the system components to provide versatility. The camera uses a high performance design which produces near film quality images from an electronic system. The optical system of the camera incorporates a conventional camera body that was slightly modified, thus permitting the use of conventional camera accessories, such as telephoto lenses, wide-angle lenses, auto-focusing circuitry, auto-exposure circuitry, flash units, and the like. An image sensor, such as a charge coupled device ('CCD') collects the photons that pass through the camera aperture when the shutter is opened, and produces an analog electrical signal indicative of the image. The analog image signal is read out of the CCD and is processed by preamplifier circuitry, a correlated double sampler, and a sample and hold circuit before it is converted to a digital signal. The analog-to-digital converter has an accuracy of eight bits to insure accuracy during the conversion. Two types of data ports are included for two different data transfer needs. One data port comprises a general purpose industrial standard port and the other a high speed/high performance application specific port. The system uses removable hard disks as its permanent storage media. The hard disk receives the digital image signal from the memory buffer and correlates the image signal with other sensed parameters, such as longitudinal or other information. When the storage capacity of the hard disk has been filled, the disk can be replaced with a new disk.

  7. Electronic Still Camera

    NASA Technical Reports Server (NTRS)

    Holland, S. Douglas (Inventor)

    1992-01-01

    A handheld, programmable, digital camera is disclosed that supports a variety of sensors and has program control over the system components to provide versatility. The camera uses a high performance design which produces near film quality images from an electronic system. The optical system of the camera incorporates a conventional camera body that was slightly modified, thus permitting the use of conventional camera accessories, such as telephoto lenses, wide-angle lenses, auto-focusing circuitry, auto-exposure circuitry, flash units, and the like. An image sensor, such as a charge coupled device ('CCD') collects the photons that pass through the camera aperture when the shutter is opened, and produces an analog electrical signal indicative of the image. The analog image signal is read out of the CCD and is processed by preamplifier circuitry, a correlated double sampler, and a sample and hold circuit before it is converted to a digital signal. The analog-to-digital converter has an accuracy of eight bits to insure accuracy during the conversion. Two types of data ports are included for two different data transfer needs. One data port comprises a general purpose industrial standard port and the other a high speed/high performance application specific port. The system uses removable hard disks as its permanent storage media. The hard disk receives the digital image signal from the memory buffer and correlates the image signal with other sensed parameters, such as longitudinal or other information. When the storage capacity of the hard disk has been filled, the disk can be replaced with a new disk.

  8. Imaging Emission Spectra with Handheld and Cellphone Cameras

    NASA Astrophysics Data System (ADS)

    Sitar, David

    2012-12-01

    As point-and-shoot digital camera technology advances it is becoming easier to image spectra in a laboralory setting on a shoestring budget and get immediale results. With this in mind, I wanted to test three cameras to see how their results would differ. Two undergraduate physics students and I used one handheld 7.1 megapixel (MP) digital Cannon point-and-shoot auto focusing camera and two different cellphone cameras: one at 6.1 MP and the other at 5.1 MP.

  9. Calibration of the MSL/ChemCam/LIBS Remote Sensing Composition Instrument

    NASA Technical Reports Server (NTRS)

    Wiens, R. C.; Maurice S.; Bender, S.; Barraclough, B. L.; Cousin, A.; Forni, O.; Ollila, A.; Newsom, H.; Vaniman, D.; Clegg, S.; hide

    2011-01-01

    The ChemCam instrument suite on board the 2011 Mars Science Laboratory (MSL) Rover, Curiosity, will provide remote-sensing composition information for rock and soil samples within seven meters of the rover using a laser-induced breakdown spectroscopy (LIBS) system, and will provide context imaging with a resolution of 0.10 mradians using the remote micro-imager (RMI) camera. The high resolution is needed to image the small analysis footprint of the LIBS system, at 0.2-0.6 mm diameter. This fine scale analytical capability will enable remote probing of stratigraphic layers or other small features the size of "blueberries" or smaller. ChemCam is intended for rapid survey analyses within 7 m of the rover, with each measurement taking less than 6 minutes. Repeated laser pulses remove dust coatings and provide depth profiles through weathering layers, allowing detailed investigation of rock varnish features as well as analysis of the underlying pristine rock composition. The LIBS technique uses brief laser pulses greater than 10 MW/square mm to ablate and electrically excite material from the sample of interest. The plasma emits photons with wavelengths characteristic of the elements present in the material, permitting detection and quantification of nearly all elements, including the light elements H, Li, Be, B, C, N, O. ChemCam LIBS projects 14 mJ of 1067 nm photons on target and covers a spectral range of 240-850 nm with resolutions between 0.15 and 0.60 nm FWHM. The Nd:KGW laser is passively cooled and is tuned to provide maximum power output from -10 to 0 C, though it can operate at 20% degraded energy output at room temperature. Preliminary calibrations were carried out on the flight model (FM) in 2008. However, the detectors were replaced in 2009, and final calibrations occurred in April-June, 2010. This presentation describes the LIBS calibration and characterization procedures and results, and details plans for final analyses during rover system thermal testing

  10. Relative and Absolute Calibration of a Multihead Camera System with Oblique and Nadir Looking Cameras for a Uas

    NASA Astrophysics Data System (ADS)

    Niemeyer, F.; Schima, R.; Grenzdörffer, G.

    2013-08-01

    Numerous unmanned aerial systems (UAS) are currently flooding the market. For the most diverse applications UAVs are special designed and used. Micro and mini UAS (maximum take-off weight up to 5 kg) are of particular interest, because legal restrictions are still manageable but also the payload capacities are sufficient for many imaging sensors. Currently a camera system with four oblique and one nadir looking cameras is under development at the Chair for Geodesy and Geoinformatics. The so-called "Four Vision" camera system was successfully built and tested in the air. A MD4-1000 UAS from microdrones is used as a carrier system. Light weight industrial cameras are used and controlled by a central computer. For further photogrammetric image processing, each individual camera, as well as all the cameras together have to be calibrated. This paper focuses on the determination of the relative orientation between the cameras with the „Australis" software and will give an overview of the results and experiences of test flights.

  11. Use of alternative–complementary-medicine (CAM) in Calabrian children

    PubMed Central

    2012-01-01

    Objective The use of complementary and alternative medicine (CAM) has not been widely studied among children in Italy. ISTAT-2005 survey showed a prevalence of 10% concerning children treated with CAM. The lack of data about the use of CAM in pediatrics in the South of Italy aimed us to conduct an epidemiological inquiry in Calabria. Methods The study has been conducted from 2009 and 2011 at the Pediatric Units of: University “Magna Graecia”- Catanzaro (CZ), Pugliese-Ciaccio Hospital-Catanzaro (CZ), Annunziata Hospital-Cosenza (CS), Jazzolino Hospital- ViboValentia (VV), Riuniti Hospitals- Reggio Calabria (RC) and San Giovanni di Dio Hospital- Crotone (KR). All information was collected through a questionnaire proposed to children’s parents admitted to these hospitals as out-patients or in-patients. Results 1387 parents were approached to complete the questionnaire. 21(1,5%) refused to answer. A total of 1366 questionnaire was analyzed: 378 at CZ , 450 at CS, 131 at KR, 201 at VV and 206 at RC, with a response rate of 98,5%. In total, the percentage of children using CAM varied from 18% in Crotone to 38% in Cosenza. The parents who used CAM for their children were older and with a higher education. Phytotherapy was preferred to homeopathy. The gastrointestinal pathologies and upper respiratory tract are those ones for which frequently parents recur to CAM. Of note we have not to disregard their use “ to strengthen” the immune system. In most of cases CAM have been prescribed by pediatrician. Conclusions Our study remarks that the use of CAM is increased dramatically among the calabrian children in the last years as well as in other countries. Pediatricians need to improve their knowledge about CAM in order to better manage the parental attitude. PMID:23231804

  12. The pineapple genome and the evolution of CAM photosynthesis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ming, Ray; VanBuren, Robert; Wai, Ching Man

    Pineapple (Ananas comosus (L.) Merr.) is the most economically valuable crop possessing crassulacean acid metabolism (CAM), a photosynthetic carbon assimilation pathway with high water-use efficiency, and the second most important tropical fruit. We sequenced the genomes of pineapple varieties F153 and MD2 and a wild pineapple relative, Ananas bracteatus accession CB5. The pineapple genome has one fewer ancient whole-genome duplication event than sequenced grass genomes and a conserved karyotype with seven chromosomes from before the ρ duplication event. The pineapple lineage has transitioned from C 3 photosynthesis to CAM, with CAM-related genes exhibiting a diel expression pattern in photosynthetic tissues.more » CAM pathway genes were enriched with cis-regulatory elements associated with the regulation of circadian clock genes, providing the first cis-regulatory link between CAM and circadian clock regulation. Lastly, we found pineapple CAM photosynthesis evolved by the reconfiguration of pathways in C 3 plants, through the regulatory neofunctionalization of preexisting genes and not through the acquisition of neofunctionalized genes via whole-genome or tandem gene duplication.« less

  13. The pineapple genome and the evolution of CAM photosynthesis.

    PubMed

    Ming, Ray; VanBuren, Robert; Wai, Ching Man; Tang, Haibao; Schatz, Michael C; Bowers, John E; Lyons, Eric; Wang, Ming-Li; Chen, Jung; Biggers, Eric; Zhang, Jisen; Huang, Lixian; Zhang, Lingmao; Miao, Wenjing; Zhang, Jian; Ye, Zhangyao; Miao, Chenyong; Lin, Zhicong; Wang, Hao; Zhou, Hongye; Yim, Won C; Priest, Henry D; Zheng, Chunfang; Woodhouse, Margaret; Edger, Patrick P; Guyot, Romain; Guo, Hao-Bo; Guo, Hong; Zheng, Guangyong; Singh, Ratnesh; Sharma, Anupma; Min, Xiangjia; Zheng, Yun; Lee, Hayan; Gurtowski, James; Sedlazeck, Fritz J; Harkess, Alex; McKain, Michael R; Liao, Zhenyang; Fang, Jingping; Liu, Juan; Zhang, Xiaodan; Zhang, Qing; Hu, Weichang; Qin, Yuan; Wang, Kai; Chen, Li-Yu; Shirley, Neil; Lin, Yann-Rong; Liu, Li-Yu; Hernandez, Alvaro G; Wright, Chris L; Bulone, Vincent; Tuskan, Gerald A; Heath, Katy; Zee, Francis; Moore, Paul H; Sunkar, Ramanjulu; Leebens-Mack, James H; Mockler, Todd; Bennetzen, Jeffrey L; Freeling, Michael; Sankoff, David; Paterson, Andrew H; Zhu, Xinguang; Yang, Xiaohan; Smith, J Andrew C; Cushman, John C; Paull, Robert E; Yu, Qingyi

    2015-12-01

    Pineapple (Ananas comosus (L.) Merr.) is the most economically valuable crop possessing crassulacean acid metabolism (CAM), a photosynthetic carbon assimilation pathway with high water-use efficiency, and the second most important tropical fruit. We sequenced the genomes of pineapple varieties F153 and MD2 and a wild pineapple relative, Ananas bracteatus accession CB5. The pineapple genome has one fewer ancient whole-genome duplication event than sequenced grass genomes and a conserved karyotype with seven chromosomes from before the ρ duplication event. The pineapple lineage has transitioned from C3 photosynthesis to CAM, with CAM-related genes exhibiting a diel expression pattern in photosynthetic tissues. CAM pathway genes were enriched with cis-regulatory elements associated with the regulation of circadian clock genes, providing the first cis-regulatory link between CAM and circadian clock regulation. Pineapple CAM photosynthesis evolved by the reconfiguration of pathways in C3 plants, through the regulatory neofunctionalization of preexisting genes and not through the acquisition of neofunctionalized genes via whole-genome or tandem gene duplication.

  14. The pineapple genome and the evolution of CAM photosynthesis

    DOE PAGES

    Ming, Ray; VanBuren, Robert; Wai, Ching Man; ...

    2015-11-02

    Pineapple (Ananas comosus (L.) Merr.) is the most economically valuable crop possessing crassulacean acid metabolism (CAM), a photosynthetic carbon assimilation pathway with high water-use efficiency, and the second most important tropical fruit. We sequenced the genomes of pineapple varieties F153 and MD2 and a wild pineapple relative, Ananas bracteatus accession CB5. The pineapple genome has one fewer ancient whole-genome duplication event than sequenced grass genomes and a conserved karyotype with seven chromosomes from before the ρ duplication event. The pineapple lineage has transitioned from C 3 photosynthesis to CAM, with CAM-related genes exhibiting a diel expression pattern in photosynthetic tissues.more » CAM pathway genes were enriched with cis-regulatory elements associated with the regulation of circadian clock genes, providing the first cis-regulatory link between CAM and circadian clock regulation. Lastly, we found pineapple CAM photosynthesis evolved by the reconfiguration of pathways in C 3 plants, through the regulatory neofunctionalization of preexisting genes and not through the acquisition of neofunctionalized genes via whole-genome or tandem gene duplication.« less

  15. L1CAM in the Early Enteric and Urogenital System

    PubMed Central

    Pechriggl, Elisabeth Judith; Concin, Nicole; Blumer, Michael J.; Bitsche, Mario; Zwierzina, Marit; Dudas, Jozsef; Koziel, Katarzyna; Altevogt, Peter; Zeimet, Alain-Gustave; Fritsch, Helga

    2016-01-01

    L1 cell adhesion molecule (L1CAM) is a transmembrane molecule belonging to the L1 protein family. It has shown to be a key player in axonal guidance in the course of neuronal development. Furthermore, L1CAM is also crucial for the establishment of the enteric and urogenital organs and is aberrantly expressed in cancer originating in these organs. Carcinogenesis and embryogenesis follow a lot of similar molecular pathways, but unfortunately, comprehensive data on L1CAM expression and localization in human developing organs are lacking so far. In the present study we, therefore, examined the spatiotemporal distribution of L1CAM in the early human fetal period (weeks 8–12 of gestation) by means of immunohistochemistry and in situ hybridization (ISH). In the epithelia of the gastrointestinal organs, L1CAM localization cannot be observed in the examined stages most likely due to their advanced polarization and differentiation. Despite these results, our ISH data indicate weak L1CAM expression, but only in few epithelial cells. The genital tracts, however, are distinctly L1CAM positive throughout the entire fetal period. We, therefore, conclude that in embryogenesis L1CAM is crucial for further differentiation of epithelia. PMID:28026654

  16. Therapeutic Uses of the WebCam in Child Psychiatry

    ERIC Educational Resources Information Center

    Chlebowski, Susan; Fremont, Wanda

    2011-01-01

    Objective: The authors provide examples for the use of the WebCam as a therapeutic tool in child psychiatry, discussing cases to demonstrate the application of the WebCam, which is most often used in psychiatry training programs during resident supervision and for case presentations. Method: Six cases illustrate the use of the WebCam in individual…

  17. Abnormal placental development and early embryonic lethality in EpCAM-null mice.

    PubMed

    Nagao, Keisuke; Zhu, Jianjian; Heneghan, Mallorie B; Hanson, Jeffrey C; Morasso, Maria I; Tessarollo, Lino; Mackem, Susan; Udey, Mark C

    2009-12-31

    EpCAM (CD326) is encoded by the tacstd1 gene and expressed by a variety of normal and malignant epithelial cells and some leukocytes. Results of previous in vitro experiments suggested that EpCAM is an intercellular adhesion molecule. EpCAM has been extensively studied as a potential tumor marker and immunotherapy target, and more recent studies suggest that EpCAM expression may be characteristic of cancer stem cells. To gain insights into EpCAM function in vivo, we generated EpCAM -/- mice utilizing an embryonic stem cell line with a tacstd1 allele that had been disrupted. Gene trapping resulted in a protein comprised of the N-terminus of EpCAM encoded by 2 exons of the tacstd1 gene fused in frame to betageo. EpCAM +/- mice were viable and fertile and exhibited no obvious abnormalities. Examination of EpCAM +/- embryos revealed that betageo was expressed in several epithelial structures including developing ears (otocysts), eyes, branchial arches, gut, apical ectodermal ridges, lungs, pancreas, hair follicles and others. All EpCAM -/- mice died in utero by E12.5, and were small, developmentally delayed, and displayed prominent placental abnormalities. In developing placentas, EpCAM was expressed throughout the labyrinthine layer and by spongiotrophoblasts as well. Placentas of EpCAM -/- embryos were compact, with thin labyrinthine layers lacking prominent vascularity. Parietal trophoblast giant cells were also dramatically reduced in EpCAM -/- placentas. EpCAM was required for differentiation or survival of parietal trophoblast giant cells, normal development of the placental labyrinth and establishment of a competent maternal-fetal circulation. The findings in EpCAM-reporter mice suggest involvement of this molecule in development of vital organs including the gut, kidneys, pancreas, lungs, eyes, and limbs.

  18. EpCAM expression in primary tumour tissues and metastases: an immunohistochemical analysis.

    PubMed

    Spizzo, Gilbert; Fong, Dominic; Wurm, Martin; Ensinger, Christian; Obrist, Peter; Hofer, Carina; Mazzoleni, Guido; Gastl, Guenther; Went, Philip

    2011-05-01

    Epithelial cell adhesion molecule (EpCAM) is a cell surface protein with oncogenic features that is expressed on healthy human epithelia and corresponding malignant tumours. EpCAM expression frequently correlates with more aggressive tumour behaviour and new EpCAM-specific therapeutic agents have recently been approved for clinical use in patients with cancer. However, no consensus exists on how and when to evaluate EpCAM expression in patients with cancer. EpCAM expression was assessed by a well-established immunohistochemical staining protocol in 2291 primary tumour tissues and in 108 metastases using the EpCAM-specific antibody clone VU1D9. A total immunostaining score was calculated as the product of a proportion score and an intensity score. Four expression subgroups (no, weak, moderate and intense) were defined. As described previously, the term 'EpCAM overexpression' was reserved for tissues showing a total immunostaining score >4. EpCAM was highly expressed in most tumours of gastrointestinal origin and in some carcinomas of the genitourinary tract. However, hepatocellular carcinomas, clear cell renal cell cancer, urothelial cancer and squamous cell cancers were frequently EpCAM negative. EpCAM expression in breast cancer depended on the histological subtype; lobular histology usually showed no or weak expression. Most metastases were EpCAM positive and they frequently reflected the expression phenotype of the primary tumour. EpCAM expression was detected on adenocarcinomas of various primary sites. If EpCAM-specific antibodies are intended to be used in patients with cancer, we recommend prior immunohistochemical evaluation of EpCAM expression, particularly in patients with renal cell cancer, hepatocellular carcinoma, urothelial carcinoma, breast cancer and squamous cell carcinomas.

  19. A CAM- and starch-deficient mutant of the facultative CAM species Mesembryanthemum crystallinum reconciles sink demands by repartitioning carbon during acclimation to salinity

    PubMed Central

    Haider, Muhammad Sajjad; Barnes, Jeremy D.; Cushman, John C.; Borland, Anne M.

    2012-01-01

    In the halophytic species Mesembryanthemum crystallinum, the induction of crassulacean acid metabolism (CAM) by salinity requires a substantial investment of resources in storage carbohydrates to provide substrate for nocturnal CO2 uptake. Acclimation to salinity also requires the synthesis and accumulation of cyclitols as compatible solutes, maintenance of root respiration, and nitrate assimilation. This study assessed the hierarchy and coordination of sinks for carbohydrate in leaves and roots during acclimation to salinity in M. crystallinum. By comparing wild type and a CAM-/starch-deficient mutant of this species, it was sought to determine if other metabolic sinks could compensate for a curtailment in CAM and enable acclimation to salinity. Under salinity, CAM deficiency reduced 24 h photosynthetic carbon gain by >50%. Cyclitols were accumulated to comparable levels in leaves and roots of both the wild type and mutant, but represented only 5% of 24 h carbon balance. Dark respiration of leaves and roots was a stronger sink for carbohydrate in the mutant compared with the wild type and implied higher maintenance costs for the metabolic processes underpinning acclimation to salinity when CAM was curtailed. CAM required the nocturnal mobilization of >70% of primary carbohydrate in the wild type and >85% of carbohydrate in the mutant. The substantial allocation of carbohydrate to CAM limited the export of sugars to roots, and the root:shoot ratio declined under salinity. The data suggest a key role for the vacuole in regulating the supply and demand for carbohydrate over the day/night cycle in the starch-/CAM-deficient mutant. PMID:22219316

  20. Xi-CAM v1.2.3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    PANDOLFI, RONALD; KUMAR, DINESH; VENKATAKRISHNAN, SINGANALLUR

    Xi-CAM aims to provide a community driven platform for multimodal analysis in synchrotron science. The platform core provides a robust plugin infrastructure for extensibility, allowing continuing development to simply add further functionality. Current modules include tools for characterization with (GI)SAXS, Tomography, and XAS. This will continue to serve as a development base as algorithms for multimodal analysis develop. Seamless remote data access, visualization and analysis are key elements of Xi-CAM, and will become critical to synchrotron data infrastructure as expectations for future data volume and acquisition rates rise with continuously increasing throughputs. The highly interactive design elements of Xi-cam willmore » similarly support a generation of users which depend on immediate data quality feedback during high-throughput or burst acquisition modes.« less

  1. No Ly α emitters detected around a QSO at z = 6.4: Suppressed by the QSO?★

    NASA Astrophysics Data System (ADS)

    Goto, Tomotsugu; Utsumi, Yousuke; Kikuta, Satoshi; Miyazaki, Satoshi; Shiki, Kensei; Hashimoto, Tetsuya

    2017-09-01

    Understanding how quasars' (QSOs') ultraviolet (UV) radiation affects galaxy formation is vital to our understanding of the reionization era. Using a custom-made narrow-band filter, NB906, on Subaru/Suprime-Cam, we investigated the number density of Ly α emitters (LAEs) around a QSO at z = 6.4. To date, this is the highest redshift narrow-band observation, where LAEs around a luminous QSO are investigated. Due to the large field of view of Suprime-Cam, our survey area is ˜5400 cMpc2, much larger than previous studies at z = 5.7 (˜200 cMpc2). In this field, we previously found a factor of 7 overdensity of Lyman break galaxies. Based on this, we expected to detect ˜100 LAEs down to NB906 = 25 ABmag. However, our 6.4 h exposure found none. The obtained upper limit on the number density of LAEs is more than an order lower than the blank fields. Furthermore, this lower density of LAEs spans a large scale of 10 pMpc across. A simple argument suggests that a strong UV radiation from the QSO can suppress star formation in haloes with Mvir < 1010 M⊙ within a pMpc from the QSO, but the deficit at the edge of the field (5 pMpc) remains to be explained.

  2. iPhone 4s and iPhone 5s Imaging of the Eye.

    PubMed

    Jalil, Maaz; Ferenczy, Sandor R; Shields, Carol L

    2017-01-01

    To evaluate the technical feasibility of a consumer-grade cellular iPhone camera as an ocular imaging device compared to existing ophthalmic imaging equipment for documentation purposes. A comparison of iPhone 4s and 5s images was made with external facial images (macrophotography) using Nikon cameras, slit-lamp images (microphotography) using Zeiss photo slit-lamp camera, and fundus images (fundus photography) using RetCam II. In an analysis of six consecutive patients with ophthalmic conditions, both iPhones achieved documentation of external findings (macrophotography) using standard camera modality, tap to focus, and built-in flash. Both iPhones achieved documentation of anterior segment findings (microphotography) during slit-lamp examination through oculars. Both iPhones achieved fundus imaging using standard video modality with continuous iPhone illumination through an ophthalmic lens. Comparison to standard ophthalmic cameras, macrophotography and microphotography were excellent. In comparison to RetCam fundus photography, iPhone fundus photography revealed smaller field and was technically more difficult to obtain, but the quality was nearly similar to RetCam. iPhone versions 4s and 5s can provide excellent ophthalmic macrophotography and microphotography and adequate fundus photography. We believe that iPhone imaging could be most useful in settings where expensive, complicated, and cumbersome imaging equipment is unavailable.

  3. Nucleic acid encoding DS-CAM proteins and products related thereto

    DOEpatents

    Korenberg, Julie R.

    2005-11-01

    In accordance with the present invention, there are provided Down Syndrome-Cell Adhesion Molecule (DS-CAM) proteins. Nucleic acid sequences encoding such proteins and assays employing same are also disclosed. The invention DS-CAM proteins can be employed in a variety of ways, for example, for the production of anti-DS-CAM antibodies thereto, in therapeutic compositions and methods employing such proteins and/or antibodies. DS-CAM proteins are also useful in bioassays to identify agonists and antagonists thereto.

  4. Thyroid Disease and Complementary and Alternative Medicine (CAM)

    MedlinePlus

    ... spirit; this combines standard medicine with CAM practices. TYPES OF COMPLEMENTARY AND ALTERNATIVE MEDICINE (CAM) The NIH ... on stories from a handful of people) or qualitative evidence (based on feelings about the treatment) is ...

  5. Cameras on the moon with Apollos 15 and 16.

    NASA Technical Reports Server (NTRS)

    Page, T.

    1972-01-01

    Description of the cameras used for photography and television by Apollo 15 and 16 missions, covering a hand-held Hasselblad camera for black and white panoramic views at locations visited by the astronauts, a special stereoscopic camera designed by astronomer Tom Gold, a 16-mm movie camera used on the Apollo 15 and 16 Rovers, and several TV cameras. Details are given on the far-UV camera/spectrograph of the Apollo 16 mission. An electronographic camera converts UV light to electrons which are ejected by a KBr layer at the focus of an f/1 Schmidt camera and darken photographic films much more efficiently than far-UV. The astronomical activity of the Apollo 16 astronauts on the moon, using this equipment, is discussed.

  6. SonotaCo network and CAMS

    NASA Astrophysics Data System (ADS)

    Koseki, Masahiro

    2017-04-01

    You might think that the newly developed CAMS video system can get much more fine results than the system of SonotaCo network. There are small differences between them surely, but the comparison between the statistics of them reveals both data are comparable in accuracy. We find that the SonotaCo system cannot detect slow velocity meteors as good as CAMS but it is superior for faster meteors. There is a more important difference between them, that is, the definition of meteor showers and this is resulting in curious stream data.

  7. Super-resolved all-refocused image with a plenoptic camera

    NASA Astrophysics Data System (ADS)

    Wang, Xiang; Li, Lin; Hou, Guangqi

    2015-12-01

    This paper proposes an approach to produce the super-resolution all-refocused images with the plenoptic camera. The plenoptic camera can be produced by putting a micro-lens array between the lens and the sensor in a conventional camera. This kind of camera captures both the angular and spatial information of the scene in one single shot. A sequence of digital refocused images, which are refocused at different depth, can be produced after processing the 4D light field captured by the plenoptic camera. The number of the pixels in the refocused image is the same as that of the micro-lens in the micro-lens array. Limited number of the micro-lens will result in poor low resolution refocused images. Therefore, not enough details will exist in these images. Such lost details, which are often high frequency information, are important for the in-focus part in the refocused image. We decide to super-resolve these in-focus parts. The result of image segmentation method based on random walks, which works on the depth map produced from the 4D light field data, is used to separate the foreground and background in the refocused image. And focusing evaluation function is employed to determine which refocused image owns the clearest foreground part and which one owns the clearest background part. Subsequently, we employ single image super-resolution method based on sparse signal representation to process the focusing parts in these selected refocused images. Eventually, we can obtain the super-resolved all-focus image through merging the focusing background part and the focusing foreground part in the way of digital signal processing. And more spatial details will be kept in these output images. Our method will enhance the resolution of the refocused image, and just the refocused images owning the clearest foreground and background need to be super-resolved.

  8. The pineapple genome and the evolution of CAM photosynthesis

    PubMed Central

    Ming, Ray; VanBuren, Robert; Wai, Ching Man; Tang, Haibao; Schatz, Michael C.; Bowers, John E.; Lyons, Eric; Wang, Ming-Li; Chen, Jung; Biggers, Eric; Zhang, Jisen; Huang, Lixian; Zhang, Lingmao; Miao, Wenjing; Zhang, Jian; Ye, Zhangyao; Miao, Chenyong; Lin, Zhicong; Wang, Hao; Zhou, Hongye; Yim, Won C.; Priest, Henry D.; Zheng, Chunfang; Woodhouse, Margaret; Edger, Patrick P.; Guyot, Romain; Guo, Hao-Bo; Guo, Hong; Zheng, Guangyong; Singh, Ratnesh; Sharma, Anupma; Min, Xiangjia; Zheng, Yun; Lee, Hayan; Gurtowski, James; Sedlazeck, Fritz J.; Harkess, Alex; McKain, Michael R.; Liao, Zhenyang; Fang, Jingping; Liu, Juan; Zhang, Xiaodan; Zhang, Qing; Hu, Weichang; Qin, Yuan; Wang, Kai; Chen, Li-Yu; Shirley, Neil; Lin, Yann-Rong; Liu, Li-Yu; Hernandez, Alvaro G.; Wright, Chris L.; Bulone, Vincent; Tuskan, Gerald A.; Heath, Katy; Zee, Francis; Moore, Paul H.; Sunkar, Ramanjulu; Leebens-Mack, James H.; Mockler, Todd; Bennetzen, Jeffrey L.; Freeling, Michael; Sankoff, David; Paterson, Andrew H.; Zhu, Xinguang; Yang, Xiaohan; Smith, J. Andrew C.; Cushman, John C.; Paull, Robert E.; Yu, Qingyi

    2016-01-01

    Pineapple (Ananas comosus (L.) Merr.) is the most economically valuable crop possessing crassulacean acid metabolism (CAM), a photosynthetic carbon assimilation pathway with high water use efficiency, and the second most important tropical fruit after banana in terms of international trade. We sequenced the genomes of pineapple varieties ‘F153’ and ‘MD2’, and a wild pineapple relative A. bracteatus accession CB5. The pineapple genome has one fewer ancient whole genome duplications than sequenced grass genomes and, therefore, provides an important reference for elucidating gene content and structure in the last common ancestor of extant members of the grass family (Poaceae). Pineapple has a conserved karyotype with seven pre rho duplication chromosomes that are ancestral to extant grass karyotypes. The pineapple lineage has transitioned from C3 photosynthesis to CAM with CAM-related genes exhibiting a diel expression pattern in photosynthetic tissues using beta-carbonic anhydrase (βCA) for initial capture of CO2. Promoter regions of all three βCA genes contain a CCA1 binding site that can bind circadian core oscillators. CAM pathway genes were enriched with cis-regulatory elements including the morning (CCACAC) and evening (AAAATATC) elements associated with regulation of circadian-clock genes, providing the first link between CAM and the circadian clock regulation. Gene-interaction network analysis revealed both activation and repression of regulatory elements that control key enzymes in CAM photosynthesis, indicating that CAM evolved by reconfiguration of pathways preexisting in C3 plants. Pineapple CAM photosynthesis is the result of regulatory neofunctionalization of preexisting gene copies and not acquisition of neofunctionalized genes via whole genome or tandem gene duplication. PMID:26523774

  9. Different CAD/CAM-processing routes for zirconia restorations: influence on fitting accuracy.

    PubMed

    Kohorst, Philipp; Junghanns, Janet; Dittmer, Marc P; Borchers, Lothar; Stiesch, Meike

    2011-08-01

    The aim of the present in vitro study was to evaluate the influence of different processing routes on the fitting accuracy of four-unit zirconia fixed dental prostheses (FDPs) fabricated by computer-aided design/computer-aided manufacturing (CAD/CAM). Three groups of zirconia frameworks with ten specimens each were fabricated. Frameworks of one group (CerconCAM) were produced by means of a laboratory CAM-only system. The other frameworks were made with different CAD/CAM systems; on the one hand by in-laboratory production (CerconCAD/CAM) and on the other hand by centralized production in a milling center (Compartis) after forwarding geometrical data. Frameworks were then veneered with the recommended ceramics, and marginal accuracy was determined using a replica technique. Horizontal marginal discrepancy, vertical marginal discrepancy, absolute marginal discrepancy, and marginal gap were evaluated. Statistical analyses were performed by one-way analysis of variance (ANOVA), with the level of significance chosen at 0.05. Mean horizontal discrepancies ranged between 22 μm (CerconCAM) and 58 μm (Compartis), vertical discrepancies ranged between 63 μm (CerconCAD/CAM) and 162 μm (CerconCAM), and absolute marginal discrepancies ranged between 94 μm (CerconCAD/CAM) and 181 μm (CerconCAM). The marginal gap varied between 72 μm (CerconCAD/CAM) and 112 μm (CerconCAM, Compartis). Statistical analysis revealed that, with all measurements, the marginal accuracy of the zirconia FDPs was significantly influenced by the processing route used (p < 0.05). Within the limitations of this study, all restorations showed a clinically acceptable marginal accuracy; however, the results suggest that the CAD/CAM systems are more precise than the CAM-only system for the manufacture of four-unit FDPs.

  10. The use of economic evaluation in CAM: an introductory framework

    PubMed Central

    2010-01-01

    Background For CAM to feature prominently in health care decision-making there is a need to expand the evidence-base and to further incorporate economic evaluation into research priorities. In a world of scarce health care resources and an emphasis on efficiency and clinical efficacy, CAM, as indeed do all other treatments, requires rigorous evaluation to be considered in budget decision-making. Methods Economic evaluation provides the tools to measure the costs and health consequences of CAM interventions and thereby inform decision making. This article offers CAM researchers an introductory framework for understanding, undertaking and disseminating economic evaluation. The types of economic evaluation available for the study of CAM are discussed, and decision modelling is introduced as a method for economic evaluation with much potential for use in CAM. Two types of decision models are introduced, decision trees and Markov models, along with a worked example of how each method is used to examine costs and health consequences. This is followed by a discussion of how this information is used by decision makers. Conclusions Undoubtedly, economic evaluation methods form an important part of health care decision making. Without formal training it can seem a daunting task to consider economic evaluation, however, multidisciplinary teams provide an opportunity for health economists, CAM practitioners and other interested researchers, to work together to further develop the economic evaluation of CAM. PMID:21067622

  11. The use of economic evaluation in CAM: an introductory framework.

    PubMed

    Ford, Emily; Solomon, Daniela; Adams, Jon; Graves, Nicholas

    2010-11-11

    For CAM to feature prominently in health care decision-making there is a need to expand the evidence-base and to further incorporate economic evaluation into research priorities.In a world of scarce health care resources and an emphasis on efficiency and clinical efficacy, CAM, as indeed do all other treatments, requires rigorous evaluation to be considered in budget decision-making. Economic evaluation provides the tools to measure the costs and health consequences of CAM interventions and thereby inform decision making. This article offers CAM researchers an introductory framework for understanding, undertaking and disseminating economic evaluation. The types of economic evaluation available for the study of CAM are discussed, and decision modelling is introduced as a method for economic evaluation with much potential for use in CAM. Two types of decision models are introduced, decision trees and Markov models, along with a worked example of how each method is used to examine costs and health consequences. This is followed by a discussion of how this information is used by decision makers. Undoubtedly, economic evaluation methods form an important part of health care decision making. Without formal training it can seem a daunting task to consider economic evaluation, however, multidisciplinary teams provide an opportunity for health economists, CAM practitioners and other interested researchers, to work together to further develop the economic evaluation of CAM.

  12. Qualification Tests of Micro-camera Modules for Space Applications

    NASA Astrophysics Data System (ADS)

    Kimura, Shinichi; Miyasaka, Akira

    Visual capability is very important for space-based activities, for which small, low-cost space cameras are desired. Although cameras for terrestrial applications are continually being improved, little progress has been made on cameras used in space, which must be extremely robust to withstand harsh environments. This study focuses on commercial off-the-shelf (COTS) CMOS digital cameras because they are very small and are based on an established mass-market technology. Radiation and ultrahigh-vacuum tests were conducted on a small COTS camera that weighs less than 100 mg (including optics). This paper presents the results of the qualification tests for COTS cameras and for a small, low-cost COTS-based space camera.

  13. Optical design of portable nonmydriatic fundus camera

    NASA Astrophysics Data System (ADS)

    Chen, Weilin; Chang, Jun; Lv, Fengxian; He, Yifan; Liu, Xin; Wang, Dajiang

    2016-03-01

    Fundus camera is widely used in screening and diagnosis of retinal disease. It is a simple, and widely used medical equipment. Early fundus camera expands the pupil with mydriatic to increase the amount of the incoming light, which makes the patients feel vertigo and blurred. Nonmydriatic fundus camera is a trend of fundus camera. Desktop fundus camera is not easy to carry, and only suitable to be used in the hospital. However, portable nonmydriatic retinal camera is convenient for patient self-examination or medical stuff visiting a patient at home. This paper presents a portable nonmydriatic fundus camera with the field of view (FOV) of 40°, Two kinds of light source are used, 590nm is used in imaging, while 808nm light is used in observing the fundus in high resolving power. Ring lights and a hollow mirror are employed to restrain the stray light from the cornea center. The focus of the camera is adjusted by reposition the CCD along the optical axis. The range of the diopter is between -20m-1 and 20m-1.

  14. Aquatic CAM photosynthesis: a brief history of its discovery

    USGS Publications Warehouse

    Keeley, Jon E.

    2014-01-01

    Aquatic CAM (Crassulacean Acid Metabolism) photosynthesis was discovered while investigating an unrelated biochemical pathway concerned with anaerobic metabolism. George Bowes was a significant contributor to this project early in its infancy. Not only did he provide me with some valuable perspectives on peer review rejections, but by working with his gas exchange system I was able to take our initial observations of diel fluctuations in malic acid to the next level, showing this aquatic plant exhibited dark CO2 uptake. CAM is universal in all aquatic species of the worldwide Lycophyta genus Isoetes and non-existent in terrestrial Isoetes. Outside of this genus aquatic CAM has a limited occurrence in three other families, including the Crassulaceae. This discovery led to fascinating adventures in the highlands of the Peruvian Andes in search of Stylites, a terrestrial relative of Isoetes. Stylites is a plant that is hermetically sealed from the atmosphere and obtains all of its carbon from terrestrial sources and recycles carbon through CAM. Considering the Mesozoic origin of Isoetes in shallow pools, coupled with the fact that aquatic Isoetes universally possess CAM, suggests the earliest evolution of CAM photosynthesis was most likely not in terrestrial plants.

  15. Evaluation of NCAR CAM5 Simulated Marine Boundary Layer Cloud Properties Using a Combination of Satellite and Surface Observations

    NASA Astrophysics Data System (ADS)

    Zhang, Z.; Song, H.; Wang, M.; Ghan, S. J.; Dong, X.

    2016-12-01

    he main objective of this study is to systematically evaluate the MBL cloud properties simulated in CAM5 family models using a combination of satellite-based CloudSat/MODIS observations and ground-based observations from the ARM Azores site, with a special focus on MBL cloud microphysics and warm rain process. First, we will present a global evaluation based on satellite observations and retrievals. We will compare global cloud properties (e.g., cloud fraction, cloud vertical structure, cloud CER, COT, and LWP, as well as drizzle frequency and intensity diagnosed using the CAM5-COSP instrumental simulators) simulated in the CAM5 models with the collocated CloudSat and MODIS observations. We will also present some preliminary results from a regional evaluation based mainly on ground observations from ARM Azores site. We will compare MBL cloud properties simulated in CAM5 models over the ARM Azores site with collocated satellite (MODIS and CloudSat) and ground-based observations from the ARM site.

  16. HectoMAPping the Universe. Karl Schwarzschild Award Lecture 2014

    NASA Astrophysics Data System (ADS)

    Geller, Margaret J.; Hwang, Ho Seong

    2015-06-01

    During the last three decades progress in mapping the Universe from an age of 400 000 years to the present has been stunning. Instrument/telescope combinations have naturally determined the sampling of various redshift ranges. Here we outline the impact of the Hectospec on the MMT on exploration of the Universe in the redshift range 0.2 ⪉ z ⪉ 0.8. We focus on dense redshift surveys, SHELS and HectoMAP. SHELS is a complete magnitude limited survey covering 8 square degrees. The HectoMAP survey combines a red-selected dense redshift survey and a weak lensing map covering 50 square degrees. Combining the dense redshift survey with a Subaru HyperSuprimeCam (HSC) weak lensing map will provide a powerful probe of the way galaxies trace the distribution of dark matter on a wide range of physical scales.

  17. Thermal assessment of sunlight impinging on OSIRIS-REx OCAMS PolyCam, OTES, and IMU-sunshade MLI blankets in flight

    NASA Astrophysics Data System (ADS)

    Choi, Michael K.

    2017-09-01

    The NASA Origins, Spectral Interpretation, Resource Identification, Security, Regolith Explorer (OSIRIS-REx) spacecraft was successfully launched into orbit on September 8, 2016. It is traveling to a near-Earth asteroid (101955) Bennu, study it in detail, and bring back a pristine sample to Earth for scientific analyses. At the Outbound Cruise nominal spacecraft attitude, with Sun on +X, sunlight impinges on the OSIRIS-REx camera suite (OCAMS) PolyCam sunshade multilayer insulation (MLI) with microporous black polytetrafluoroethylene (PTFE), a portion of the PolyCam optics support tube (MLI with germanium black Kapton (GBK)), a portion of the OSIRIS-REx Thermal Emission Spectrometer (OTES) sunshade (MLI with GBK), the Inertia Measurement Unit (IMU) sunshade (MLI with GBK), and the OSIRIS-REx Laser Altimeter (OLA) sunshade (MLI with GBK). Sunlight is reflected or scattered by the above MLIs to the other components on the forward (+Z) deck. It illuminates the forward deck. A detailed thermal assessment on the solar impingement has been performed for the Proximity Ops at the asteroid, Touch-and-Go sample acquisition, and Return Cruise mission phases.

  18. Classification of igneous rocks analyzed by ChemCam at Gale crater, Mars

    DOE PAGES

    Cousin, Agnes; Sautter, Violaine; Payré, Valérie; ...

    2017-02-09

    Several recent studies have revealed that Mars is not a simple basalt-covered planet, but has a more complex geological history. In Gale crater on Mars, the Curiosity rover discovered 59 igneous rocks. This article focuses on their textures (acquired from the cameras such as MAHLI and MastCam) and their geochemical compositions that have been obtained using the ChemCam instrument. Light-toned crystals have been observed in most of the rocks. They correspond to feldspars ranging from andesines/oligoclases to anorthoclases and sanidines in the leucocratic vesiculated rocks. Darker crystals observed in all igneous rocks (except the leucocratic vesiculated ones) were analyzed bymore » LIBS and mainly identified as Fe-rich pigeonites and Fe-augites. Iron oxides have been observed in all groups whereas F-bearing minerals have been detected only in few of them. From their textural analysis and their whole-rock compositions, all these 59 igneous rocks have been classified in five different groups; from primitive rocks i.e. dark aphanitic basalts/basanites, trachybasalts, tephrites and fine/coarse-grained gabbros/norites to more evolved materials i.e. porphyritic trachyandesites, leucocratic trachytes and quartz-diorites. The basalts and gabbros are found all along the traverse of the rover, whereas the felsic rocks are located before the Kimberley formation, i.e. close to the Peace Vallis alluvial fan deposits. This suggests that these alkali rocks have been transported by fluvial activity and could come from the Northern rim of the crater, and may correspond to deeper strata buried under basaltic regolith (Sautter et al., 2015). Some of the basaltic igneous rocks are surprisingly enriched in iron, presenting low Mg# similar to the nakhlite parental melt that cannot be produced by direct melting of the Dreibus and Wanke (1986) martian primitive mantle. The basaltic rocks at Gale are thus different from Gusev basalts. They could originate from different mantle reservoirs

  19. Classification of igneous rocks analyzed by ChemCam at Gale crater, Mars

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cousin, Agnes; Sautter, Violaine; Payré, Valérie

    Several recent studies have revealed that Mars is not a simple basalt-covered planet, but has a more complex geological history. In Gale crater on Mars, the Curiosity rover discovered 59 igneous rocks. This article focuses on their textures (acquired from the cameras such as MAHLI and MastCam) and their geochemical compositions that have been obtained using the ChemCam instrument. Light-toned crystals have been observed in most of the rocks. They correspond to feldspars ranging from andesines/oligoclases to anorthoclases and sanidines in the leucocratic vesiculated rocks. Darker crystals observed in all igneous rocks (except the leucocratic vesiculated ones) were analyzed bymore » LIBS and mainly identified as Fe-rich pigeonites and Fe-augites. Iron oxides have been observed in all groups whereas F-bearing minerals have been detected only in few of them. From their textural analysis and their whole-rock compositions, all these 59 igneous rocks have been classified in five different groups; from primitive rocks i.e. dark aphanitic basalts/basanites, trachybasalts, tephrites and fine/coarse-grained gabbros/norites to more evolved materials i.e. porphyritic trachyandesites, leucocratic trachytes and quartz-diorites. The basalts and gabbros are found all along the traverse of the rover, whereas the felsic rocks are located before the Kimberley formation, i.e. close to the Peace Vallis alluvial fan deposits. This suggests that these alkali rocks have been transported by fluvial activity and could come from the Northern rim of the crater, and may correspond to deeper strata buried under basaltic regolith (Sautter et al., 2015). Some of the basaltic igneous rocks are surprisingly enriched in iron, presenting low Mg# similar to the nakhlite parental melt that cannot be produced by direct melting of the Dreibus and Wanke (1986) martian primitive mantle. The basaltic rocks at Gale are thus different from Gusev basalts. They could originate from different mantle reservoirs

  20. SNACC Extras

    NASA Astrophysics Data System (ADS)

    Huber, Mark; Scolnic, D.; Riess, A. G.; Tonry, J. L.; Rodney, S. A.; Rest, A.; Stubbs, C. W.

    2010-01-01

    The extensive application of the SuperNovAe Cross-Correlation (SNACC) filters developed by Scolnic et al. (2009) for follow-up identification and redshift of type Ia supernovae in current and upcoming supernovae surveys will itself produce a unique imaging survey. We will present a collection of simulated and actual sources from the initial observing run using the new 4-band SNACC filters with Suprime-Cam on the Subaru telescope to explore the extra potential of this unique data set.

  1. Multi-Angle Snowflake Camera Instrument Handbook

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stuefer, Martin; Bailey, J.

    2016-07-01

    The Multi-Angle Snowflake Camera (MASC) takes 9- to 37-micron resolution stereographic photographs of free-falling hydrometers from three angles, while simultaneously measuring their fall speed. Information about hydrometeor size, shape orientation, and aspect ratio is derived from MASC photographs. The instrument consists of three commercial cameras separated by angles of 36º. Each camera field of view is aligned to have a common single focus point about 10 cm distant from the cameras. Two near-infrared emitter pairs are aligned with the camera’s field of view within a 10-angular ring and detect hydrometeor passage, with the lower emitters configured to trigger the MASCmore » cameras. The sensitive IR motion sensors are designed to filter out slow variations in ambient light. Fall speed is derived from successive triggers along the fall path. The camera exposure times are extremely short, in the range of 1/25,000th of a second, enabling the MASC to capture snowflake sizes ranging from 30 micrometers to 3 cm.« less

  2. J-GEM follow-up observations of the gravitational wave source GW151226*

    NASA Astrophysics Data System (ADS)

    Yoshida, Michitoshi; Utsumi, Yousuke; Tominaga, Nozomu; Morokuma, Tomoki; Tanaka, Masaomi; Asakura, Yuichiro; Matsubayashi, Kazuya; Ohta, Kouji; Abe, Fumio; Chimasu, Sho; Furusawa, Hisanori; Itoh, Ryosuke; Itoh, Yoichi; Kanda, Yuka; Kawabata, Koji S.; Kawabata, Miho; Koshida, Shintaro; Koshimoto, Naoki; Kuroda, Daisuke; Moritani, Yuki; Motohara, Kentaro; Murata, Katsuhiro L.; Nagayama, Takahiro; Nakaoka, Tatsuya; Nakata, Fumiaki; Nishioka, Tsubasa; Saito, Yoshihiko; Terai, Tsuyoshi; Tristram, Paul J.; Yanagisawa, Kenshi; Yasuda, Naoki; Doi, Mamoru; Fujisawa, Kenta; Kawachi, Akiko; Kawai, Nobuyuki; Tamura, Yoichi; Uemura, Makoto; Yatsu, Yoichi

    2017-02-01

    We report the results of optical-infrared follow-up observations of the gravitational wave (GW) event GW151226 detected by the Advanced LIGO in the framework of J-GEM (Japanese collaboration for Gravitational wave ElectroMagnetic follow-up). We performed wide-field optical imaging surveys with the Kiso Wide Field Camera (KWFC), Hyper Suprime-Cam (HSC), and MOA-cam3. The KWFC survey started at 2.26 d after the GW event and covered 778 deg2 centered at the high Galactic region of the skymap of GW151226. We started the HSC follow-up observations from ˜12 d after the event and covered an area of 63.5 deg2 of the highest probability region of the northern sky with limiting magnitudes of 24.6 and 23.8 for the i and z bands, respectively. MOA-cam3 covered 145 deg2 of the skymap with the MOA-red filter ˜2.5 mon after the GW alert. The total area covered by the wide-field surveys was 986.5 deg2. The integrated detection probability for the observed area was ˜29%. We also performed galaxy-targeted observations with six optical and near-infrared telescopes from 1.61 d after the event. A total of 238 nearby (≤100 Mpc) galaxies were observed with a typical I band limiting magnitude of ˜19.5. We detected 13 supernova candidates with the KWFC survey, and 60 extragalactic transients with the HSC survey. Two thirds of the HSC transients were likely supernovae and the remaining one third were possible active galactic nuclei. With our observational campaign, we found no transients that are likely to be associated with GW151226.

  3. Architecture of PAU survey camera readout electronics

    NASA Astrophysics Data System (ADS)

    Castilla, Javier; Cardiel-Sas, Laia; De Vicente, Juan; Illa, Joseph; Jimenez, Jorge; Maiorino, Marino; Martinez, Gustavo

    2012-07-01

    PAUCam is a new camera for studying the physics of the accelerating universe. The camera will consist of eighteen 2Kx4K HPK CCDs: sixteen for science and two for guiding. The camera will be installed at the prime focus of the WHT (William Herschel Telescope). In this contribution, the architecture of the readout electronics system is presented. Back- End and Front-End electronics are described. Back-End consists of clock, bias and video processing boards, mounted on Monsoon crates. The Front-End is based on patch panel boards. These boards are plugged outside the camera feed-through panel for signal distribution. Inside the camera, individual preamplifier boards plus kapton cable completes the path to connect to each CCD. The overall signal distribution and grounding scheme is shown in this paper.

  4. Turnkey CAD/CAM systems' integration with IPAD systems

    NASA Technical Reports Server (NTRS)

    Blauth, R. E.

    1980-01-01

    Today's commercially available turnkey CAD/CAM systems provide a highly interactive environment, and support many specialized application functions for the design/drafting/manufacturing process. This paper presents an overview of several aerospace companies which have successfully integrated turnkey CAD/CAM systems with their own company wide engineering and manufacturing systems. It also includes a vendor's view of the benefits as well as the disadvantages of such integration efforts. Specific emphasis is placed upon the selection of standards for representing geometric engineering data and for communicating such information between different CAD/CAM systems.

  5. CamBAfx: Workflow Design, Implementation and Application for Neuroimaging

    PubMed Central

    Ooi, Cinly; Bullmore, Edward T.; Wink, Alle-Meije; Sendur, Levent; Barnes, Anna; Achard, Sophie; Aspden, John; Abbott, Sanja; Yue, Shigang; Kitzbichler, Manfred; Meunier, David; Maxim, Voichita; Salvador, Raymond; Henty, Julian; Tait, Roger; Subramaniam, Naresh; Suckling, John

    2009-01-01

    CamBAfx is a workflow application designed for both researchers who use workflows to process data (consumers) and those who design them (designers). It provides a front-end (user interface) optimized for data processing designed in a way familiar to consumers. The back-end uses a pipeline model to represent workflows since this is a common and useful metaphor used by designers and is easy to manipulate compared to other representations like programming scripts. As an Eclipse Rich Client Platform application, CamBAfx's pipelines and functions can be bundled with the software or downloaded post-installation. The user interface contains all the workflow facilities expected by consumers. Using the Eclipse Extension Mechanism designers are encouraged to customize CamBAfx for their own pipelines. CamBAfx wraps a workflow facility around neuroinformatics software without modification. CamBAfx's design, licensing and Eclipse Branding Mechanism allow it to be used as the user interface for other software, facilitating exchange of innovative computational tools between originating labs. PMID:19826470

  6. L1CAM expression in endometrial carcinomas: an ENITEC collaboration study.

    PubMed

    van der Putten, Louis Jm; Visser, Nicole Cm; van de Vijver, Koen; Santacana, Maria; Bronsert, Peter; Bulten, Johan; Hirschfeld, Marc; Colas, Eva; Gil-Moreno, Antonio; Garcia, Angel; Mancebo, Gemma; Alameda, Fransesc; Trovik, Jone; Kopperud, Reidun K; Huvila, Jutta; Schrauwen, Stefanie; Koskas, Martin; Walker, Francine; Weinberger, Vit; Minar, Lubos; Jandakova, Eva; Snijders, Marc Plm; van den Berg-van Erp, Saskia; Matias-Guiu, Xavier; Salvesen, Helga B; Amant, Frederic; Massuger, Leon Fag; Pijnenborg, Johanna Ma

    2016-09-06

    Identification of aggressive endometrioid endometrial carcinomas (EECs) and non-endometrioid carcinomas (NEECs) is essential to improve outcome. L1 cell adhesion molecule (L1CAM) expression is a strong prognostic marker in stage I EECs, but less is known about L1CAM expression in advanced-stage EECs and NEECs. This study analyses L1CAM expression in a clinically representative cohort of endometrial carcinomas. The expression of L1CAM was immunohistochemically determined in 1199 endometrial carcinomas, treated at one of the European Network for Individualized Treatment of Endometrial Cancer (ENITEC) centres. Staining was considered positive when >10% of the tumour cells expressed L1CAM. The association between L1CAM expression and several clincopathological characteristics and disease outcome was calculated. In all, L1CAM was expressed in 10% of the 935 stage I EECs, 18% of the 160 advanced stage EECs, and 75% of the 104 NEECs. The expression of L1CAM was associated with advanced stage, nodal involvement, high tumour grade, non-endometrioid histology, lymphovascular space invasion, and distant recurrences in all cases, and with reduced survival in the EECs, but not in the NEECs. The expression of L1CAM is a strong predictor of poor outcome in EECs, but not NEECs. It is strongly associated with non-endometrioid histology and distant spread, and could improve the postoperative selection of high-risk endometrial carcinomas. The value of L1CAM expression in the preoperative selection of high-risk endometrial carcinomas should be studied.

  7. L1CAM expression in endometrial carcinomas: an ENITEC collaboration study

    PubMed Central

    van der Putten, Louis JM; Visser, Nicole CM; van de Vijver, Koen; Santacana, Maria; Bronsert, Peter; Bulten, Johan; Hirschfeld, Marc; Colas, Eva; Gil-Moreno, Antonio; Garcia, Angel; Mancebo, Gemma; Alameda, Fransesc; Trovik, Jone; Kopperud, Reidun K; Huvila, Jutta; Schrauwen, Stefanie; Koskas, Martin; Walker, Francine; Weinberger, Vit; Minar, Lubos; Jandakova, Eva; Snijders, Marc PLM; van den Berg-van Erp, Saskia; Matias-Guiu, Xavier; Salvesen, Helga B; Amant, Frederic; Massuger, Leon FAG; Pijnenborg, Johanna MA

    2016-01-01

    Background: Identification of aggressive endometrioid endometrial carcinomas (EECs) and non-endometrioid carcinomas (NEECs) is essential to improve outcome. L1 cell adhesion molecule (L1CAM) expression is a strong prognostic marker in stage I EECs, but less is known about L1CAM expression in advanced-stage EECs and NEECs. This study analyses L1CAM expression in a clinically representative cohort of endometrial carcinomas. Methods: The expression of L1CAM was immunohistochemically determined in 1199 endometrial carcinomas, treated at one of the European Network for Individualized Treatment of Endometrial Cancer (ENITEC) centres. Staining was considered positive when >10% of the tumour cells expressed L1CAM. The association between L1CAM expression and several clincopathological characteristics and disease outcome was calculated. Results: In all, L1CAM was expressed in 10% of the 935 stage I EECs, 18% of the 160 advanced stage EECs, and 75% of the 104 NEECs. The expression of L1CAM was associated with advanced stage, nodal involvement, high tumour grade, non-endometrioid histology, lymphovascular space invasion, and distant recurrences in all cases, and with reduced survival in the EECs, but not in the NEECs. Conclusions: The expression of L1CAM is a strong predictor of poor outcome in EECs, but not NEECs. It is strongly associated with non-endometrioid histology and distant spread, and could improve the postoperative selection of high-risk endometrial carcinomas. The value of L1CAM expression in the preoperative selection of high-risk endometrial carcinomas should be studied. PMID:27505134

  8. X-ray Reverberation Mapping of Ci Cam

    NASA Astrophysics Data System (ADS)

    Bartlett, Elizabeth; Garcia, M.

    2009-01-01

    We have analyzed the X-ray lightcurve of the star CI Cam, the optical counterpart of the X-ray transient XTE J0421+56 using data from XMM-Newton. Our motivation is based on evidence from ground based optical interferometry from the Keck and IOTA observatories which suggests that the dust surrounding CI CAM has a taurus morphology rather than a spherical distribution as previously hypothesized. By using a technique known as reverberation mapping we have constrained the time delay between the continuum of CI Cam and the Fe-K fluorescence line, corresponding to the reflection of the continuum off the dusty taurus. The time delay yields information on the size of the taurus.

  9. Science, conservation, and camera traps

    USGS Publications Warehouse

    Nichols, James D.; Karanth, K. Ullas; O'Connel, Allan F.; O'Connell, Allan F.; Nichols, James D.; Karanth, K. Ullas

    2011-01-01

    Biologists commonly perceive camera traps as a new tool that enables them to enter the hitherto secret world of wild animals. Camera traps are being used in a wide range of studies dealing with animal ecology, behavior, and conservation. Our intention in this volume is not to simply present the various uses of camera traps, but to focus on their use in the conduct of science and conservation. In this chapter, we provide an overview of these two broad classes of endeavor and sketch the manner in which camera traps are likely to be able to contribute to them. Our main point here is that neither photographs of individual animals, nor detection history data, nor parameter estimates generated from detection histories are the ultimate objective of a camera trap study directed at either science or management. Instead, the ultimate objectives are best viewed as either gaining an understanding of how ecological systems work (science) or trying to make wise decisions that move systems from less desirable to more desirable states (conservation, management). Therefore, we briefly describe here basic approaches to science and management, emphasizing the role of field data and associated analyses in these processes. We provide examples of ways in which camera trap data can inform science and management.

  10. ChemCam passive reflectance spectroscopy of surface materials at the Curiosity landing site, Mars

    NASA Astrophysics Data System (ADS)

    Johnson, Jeffrey R.; Bell, J. F.; Bender, S.; Blaney, D.; Cloutis, E.; DeFlores, L.; Ehlmann, B.; Gasnault, O.; Gondet, B.; Kinch, K.; Lemmon, M.; Le Mouélic, S.; Maurice, S.; Rice, M.; Wiens, R. C.

    2015-03-01

    The spectrometers on the Mars Science Laboratory (MSL) ChemCam instrument were used in passive mode to record visible/near-infrared (400-840 nm) radiance from the martian surface. Using the onboard ChemCam calibration targets' housing as a reflectance standard, we developed methods to collect, calibrate, and reduce radiance observations to relative reflectance. Such measurements accurately reproduce the known reflectance spectra of other calibration targets on the rover, and represent the highest spatial resolution (0.65 mrad) and spectral sampling (<1 nm) visible/near-infrared reflectance spectra from a landed platform on Mars. Relative reflectance spectra of surface rocks and soils match those from orbital observations and multispectral data from the MSL Mastcam camera. Preliminary analyses of the band depths, spectral slopes, and reflectance ratios of the more than 2000 spectra taken during the first year of MSL operations demonstrate at least six spectral classes of materials distinguished by variations in ferrous and ferric components. Initial comparisons of ChemCam spectra to laboratory spectra of minerals and Mars analog materials demonstrate similarities with palagonitic soils and indications of orthopyroxene in some dark rocks. Magnesium-rich "raised ridges" tend to exhibit distinct near-infrared slopes. The ferric absorption downturn typically found for martian materials at <600 nm is greatly subdued in brushed rocks and drill tailings, consistent with their more ferrous nature. Calcium-sulfate veins exhibit the highest relative reflectances observed, but are still relatively red owing to the effects of residual dust. Such dust is overall less prominent on rocks sampled within the "blast zone" immediately surrounding the landing site. These samples were likely affected by the landing thrusters, which partially removed the ubiquitous dust coatings. Increased dust coatings on the calibration targets during the first year of the mission were documented by

  11. 21 CFR 872.3661 - Optical Impression Systems for CAD/CAM.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Optical Impression Systems for CAD/CAM. 872.3661... (CAD/CAM) is a device used to record the topographical characteristics of teeth, dental impressions, or... Design and Manufacturing (CAD/CAM) of Dental Restorations; Guidance for Industry and FDA.” For the...

  12. 21 CFR 872.3661 - Optical Impression Systems for CAD/CAM.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Optical Impression Systems for CAD/CAM. 872.3661... (CAD/CAM) is a device used to record the topographical characteristics of teeth, dental impressions, or... Design and Manufacturing (CAD/CAM) of Dental Restorations; Guidance for Industry and FDA.” For the...

  13. 21 CFR 872.3661 - Optical Impression Systems for CAD/CAM.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Optical Impression Systems for CAD/CAM. 872.3661... (CAD/CAM) is a device used to record the topographical characteristics of teeth, dental impressions, or... Design and Manufacturing (CAD/CAM) of Dental Restorations; Guidance for Industry and FDA.” For the...

  14. Focus collimator press for a collimator for gamma ray cameras

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    York, R.N.; York, D.L.

    A focus collimator press for collimators for gamma ray cameras is described comprising a pivot arm of fixed length mounted on a travelling pivot which is movable in the plane of a spaced apart work table surface in a direction toward and away from the work table. A press plate is carried at the opposite end of the fixed length pivot arm, and is maintained in registration with the same portion of the work table for pressing engagement with each undulating radiation opaque strip as it is added to the top of a collimator stack in process by movement ofmore » the travelling pivot inward toward the work table. This enables the press plate to maintain its relative position above the collimator stack and at the same time the angle of the press plate changes, becoming less acute in relation to the work table as the travelling pivot motes inwardly toward the work table. The fixed length of the pivot arm is substantially equal to the focal point of the converging apertures formed by each pair of undulating strips stacked together. Thus, the focal point of each aperture row falls substantially on the axis of the travelling pivot, and since it moves in the plane of the work table surface the focal point of each aperture row is directed to lie in the same common plane. When one of two collimator stacks made in this way is rotated 180 degrees and the two bonded together along their respective first strips, all focal points of every aperture row lie on the central axis of the completed collimator.« less

  15. Plenoptic camera based on a liquid crystal microlens array

    NASA Astrophysics Data System (ADS)

    Lei, Yu; Tong, Qing; Zhang, Xinyu; Sang, Hongshi; Xie, Changsheng

    2015-09-01

    A type of liquid crystal microlens array (LCMLA) with tunable focal length by the voltage signals applied between its top and bottom electrodes, is fabricated and then the common optical focusing characteristics are tested. The relationship between the focal length and the applied voltage signals is given. The LCMLA is integrated with an image sensor and further coupled with a main lens so as to construct a plenoptic camera. Several raw images at different voltage signals applied are acquired and contrasted through the LCMLA-based plenoptic camera constructed by us. Our experiments demonstrate that through utilizing a LCMLA in a plenoptic camera, the focused zone of the LCMLA-based plenoptic camera can be shifted effectively only by changing the voltage signals loaded between the electrodes of the LCMLA, which is equivalent to the extension of the depth of field.

  16. SenseCam reminiscence and action recall in memory-unimpaired people.

    PubMed

    Seamon, John G; Moskowitz, Tacie N; Swan, Ashley E; Zhong, Boyuan; Golembeski, Amy; Liong, Christopher; Narzikul, Alexa C; Sosan, Olumide A

    2014-01-01

    Case studies of memory-impaired individuals consistently show that reminiscing with SenseCam images enhances event recall. This exploratory study examined whether a similar benefit would occur for the consolidation of memories in memory-unimpaired people. We tested delayed recall for atypical actions observed on a lengthy walk. Participants used SenseCam, a diary, or no external memory aid while walking, followed by reminiscence with SenseCam images, diary entries, or no aid, either alone (self-reminiscence) or with the experimenter (social reminiscence). One week later, when tested without SenseCam images or diary entries, prior social reminiscence produced greater recall than self-reminiscence, but there were no differences between memory aid conditions for action free recall or action order recall. When methodological variables were controlled, there was no recall advantage for SenseCam reminiscence with memory-unimpaired participants. The case studies and present study differ in multiple ways, making direct comparisons problematic. SenseCam is a valuable aid to the memory impaired, but its mnemonic value for non-clinical populations remains to be determined.

  17. CAM/LIFTER forces and friction. Final report, September 15, 1988--November 30, 1991

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gabbey, D.J.; Lee, J.; Patterson, D.J.

    1992-02-01

    This report details the procedures used to measure the cam/lifter forces and friction. The present effort employed a Cummins LTA-10, and focuses on measurements and dynamic modeling of the injector train. The program was sponsored by the US Department of Energy in support of advanced diesel engine technology. The injector train was instrumented to record the instantaneous roller speed, roller pin friction torque, pushrod force, injector link force and cam speed. These measurements, together with lift profiles for pushrod and injector link displacement, enabled the friction work loss in the injector train to be determined. Other significant design criteria suchmore » as camshaft roller follower slippage and maximum loads on components were also determined. Future efforts will concentrate on the dynamic model, with tests run as required for correlation.« less

  18. WADeG Cell Phone

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2009-09-01

    The on cell phone software captures the images from the CMOS camera periodically, stores the pictures, and periodically transmits those images over the cellular network to the server. The cell phone software consists of several modules: CamTest.cpp, CamStarter.cpp, StreamIOHandler .cpp, and covertSmartDevice.cpp. The camera application on the SmartPhone is CamStarter, which is "the" user interface for the camera system. The CamStarter user interface allows a user to start/stop the camera application and transfer files to the server. The CamStarter application interfaces to the CamTest application through registry settings. Both the CamStarter and CamTest applications must be separately deployed on themore » smartphone to run the camera system application. When a user selects the Start button in CamStarter, CamTest is created as a process. The smartphone begins taking small pictures (CAPTURE mode), analyzing those pictures for certain conditions, and saving those pictures on the smartphone. This process will terminate when the user selects the Stop button. The camtest code spins off an asynchronous thread, StreamIOHandler, to check for pictures taken by the camera. The received image is then tested by StreamIOHandler to see if it meets certain conditions. If those conditions are met, the CamTest program is notified through the setting of a registry key value and the image is saved in a designated directory in a custom BMP file which includes a header and the image data. When the user selects the Transfer button in the CamStarter user interface, the covertsmartdevice code is created as a process. Covertsmartdevice gets all of the files in a designated directory, opens a socket connection to the server, sends each file, and then terminates.« less

  19. The utilisation of Complementary and Alternative Medicine (CAM) among ethnic minorities in South Korea

    PubMed Central

    2014-01-01

    Background Race has been reported to affect the use of complementary and alternative medicine (CAM), but there is very little research on the use of CAM by ethnicity in Korea. This study explores the prevalence of CAM use among ethnic minorities in South Korea. Methods The design is a descriptive and cross-sectional study. A convenience sample of ethnic minorities was recruited from two public healthcare centres in Gyeonggi province. The survey instrument included 37 questions regarding CAM use, factors influencing use of CAM, self-health management, and the socio-demographic profile of study participants. Results Sixty-two percent of study participants reported the use of CAM. Multivitamins (53.3%), acupuncture (48.9%), and traditional Korean herbal medicine (38.9%) were popular CAM modalities in our sample. Other notable CAM modalities included herbal plants, therapeutic massage, and moxibustion therapy. The majority of CAM users (52.2%) received CAM services to treat diseases or as a secondary treatment while receiving conventional care. Having positive perceptions toward the effectiveness of CAM was a major determining factor in CAM use. Conclusions Physicians need to be aware of the fact that many ethnic minorities use CAM therapies. Many CAM users reported that they want doctors to know about their CAM use and have a basic understanding of traditional medicine in their home country. Overcoming language and cultural barriers will help reduce unwanted medical complications. High prevalence of CAM use among ethnic minorities in our study warrants further studies using larger sample population. PMID:24641983

  20. The SALSA Project - High-End Aerial 3d Camera

    NASA Astrophysics Data System (ADS)

    Rüther-Kindel, W.; Brauchle, J.

    2013-08-01

    The ATISS measurement drone, developed at the University of Applied Sciences Wildau, is an electrical powered motor glider with a maximum take-off weight of 25 kg including a payload capacity of 10 kg. Two 2.5 kW engines enable ultra short take-off procedures and the motor glider design results in a 1 h endurance. The concept of ATISS is based on the idea to strictly separate between aircraft and payload functions, which makes ATISS a very flexible research platform for miscellaneous payloads. ATISS is equipped with an autopilot for autonomous flight patterns but under permanent pilot control from the ground. On the basis of ATISS the project SALSA was undertaken. The aim was to integrate a system for digital terrain modelling. Instead of a laser scanner a new design concept was chosen based on two synchronized high resolution digital cameras, one in a fixed nadir orientation and the other in a oblique orientation. Thus from every object on the ground images from different view angles are taken. This new measurement camera system MACS-TumbleCam was developed at the German Aerospace Center DLR Berlin-Adlershof especially for the ATISS payload concept. Special advantage in comparison to laser scanning is the fact, that instead of a cloud of points a surface including texture is generated and a high-end inertial orientation system can be omitted. The first test flights show a ground resolution of 2 cm and height resolution of 3 cm, which underline the extraordinary capabilities of ATISS and the MACS measurement camera system.

  1. CAD/CAM approach to improving industry productivity gathers momentum

    NASA Technical Reports Server (NTRS)

    Fulton, R. E.

    1982-01-01

    Recent results and planning for the NASA/industry Integrated Programs for Aerospace-Vehicle Design (IPAD) program for improving productivity with CAD/CAM methods are outlined. The industrial group work is being mainly done by Boeing, and progress has been made in defining the designer work environment, developing requirements and a preliminary design for a future CAD/CAM system, and developing CAD/CAM technology. The work environment was defined by conducting a detailed study of a reference design process, and key software elements for a CAD/CAM system have been defined, specifically for interactive design or experiment control processes. Further work is proceeding on executive, data management, geometry and graphics, and general utility software, and dynamic aspects of the programs being developed are outlined

  2. Camões e a cosmogonia

    NASA Astrophysics Data System (ADS)

    Costa, J. M.

    2003-08-01

    Os Lusíadas, escrito por Luis de Camões em 1572, é um poema épico renascentista e a visão Cosmogônica do autor é apresentada, principalmente, no último canto do poema, quando Tétis mostra ao Gama a Máquina do Mundo. A Cosmogonia de Camões neste poema reflete uma visão de uma época de transição, que ainda não incorporou os elementos da revolução Copernicana. É uma visão Grego- Ptolomaica e também medieval. O poeta guia-se pela tradução e notas feita por Pedro Nunes, inventor do Nonio, do Tratado da Esfera "De Sphaera" do Astrônomo Inglês John Holywood, mais conhecido pelo nome latinizado de Johannes Sacrobosco. Outra provável fonte de Camões, de acordo com Luciano Antonio Pereira da Silva em Astronomia de os Lusíadas, é o "Theoricae novae Planetarum" (1460) do astrólogo Alemão Jorge Purbáquio (1423 - 1461). A Astronomia de Os Lusíadas representa a ciência do tempo de Camões. Camões nunca emprega a palavra constelação e seu catálogo é bastante completo. A Máquina do Mundo tem a Terra no centro. Em redor, em círculos concêntricos, a lua (Diana), Mercúrio, Vênus, o Sol (Febo), Marte, Júpiter e Saturno. Envolvendo estes astros tem o firmamento seguido pelo "Céu Áqueo" ou cristalino, depois o 1o Móbil, esfera que arrasta todas as outras consigo. Este trabalho, multidisciplinar, serve tanto para ensinar aos alunos da Física como das Ciências Humanas, a concepção de mundo do renascimento de uma forma belamente poética em versos decassílabos Este trabalho também ajuda na apreciação do maior clássico da língua portuguesa e mostra como as Ciências e as artes, em geral, estão correlacionadas e refletem a visão de mundo da época em que foi produzida.

  3. Implications of atmospheric conditions for analysis of surface temperature variability derived from landscape-scale thermography.

    PubMed

    Hammerle, Albin; Meier, Fred; Heinl, Michael; Egger, Angelika; Leitinger, Georg

    2017-04-01

    Thermal infrared (TIR) cameras perfectly bridge the gap between (i) on-site measurements of land surface temperature (LST) providing high temporal resolution at the cost of low spatial coverage and (ii) remotely sensed data from satellites that provide high spatial coverage at relatively low spatio-temporal resolution. While LST data from satellite (LST sat ) and airborne platforms are routinely corrected for atmospheric effects, such corrections are barely applied for LST from ground-based TIR imagery (using TIR cameras; LST cam ). We show the consequences of neglecting atmospheric effects on LST cam of different vegetated surfaces at landscape scale. We compare LST measured from different platforms, focusing on the comparison of LST data from on-site radiometry (LST osr ) and LST cam using a commercially available TIR camera in the region of Bozen/Bolzano (Italy). Given a digital elevation model and measured vertical air temperature profiles, we developed a multiple linear regression model to correct LST cam data for atmospheric influences. We could show the distinct effect of atmospheric conditions and related radiative processes along the measurement path on LST cam , proving the necessity to correct LST cam data on landscape scale, despite their relatively low measurement distances compared to remotely sensed data. Corrected LST cam data revealed the dampening effect of the atmosphere, especially at high temperature differences between the atmosphere and the vegetated surface. Not correcting for these effects leads to erroneous LST estimates, in particular to an underestimation of the heterogeneity in LST, both in time and space. In the most pronounced case, we found a temperature range extension of almost 10 K.

  4. Biofuel crops with CAM photosynthesis: Economic potential on moisture-limited lands

    NASA Astrophysics Data System (ADS)

    Bartlett, Mark; Hartzell, Samantha; Porporato, Amilcare

    2017-04-01

    As the demand for food and renewable energy increases, the intelligent utilization of marginal lands is becoming increasingly critical. In marginal lands classified by limited rainfall or soil salinity, the cultivation of traditional C3 and C4 photosynthesis crops often is economically infeasible. However, in such lands, nontraditional crops with crassulacean acid metabolism (CAM) photosynthesis show great economic potential for cultivation. CAM crops including Opuntia (prickly pear) and Ananas (pineapple) achieve a water use efficiency which is three fold higher than C4 crops such as corn and 6-fold higher than C3 crops such as wheat, leading to a comparable annual productivity with only 20% of the water demand. This feature, combined with a shallow rooting depth and a high water storage capacity, allows CAM plants to take advantage of small, infrequent rainfall amounts in shallow, quickly draining soils. Furthermore, CAM plants typically have properties (e.g., high content of non-structural carbohydrates) that are favorable for biofuel production. Here, for marginal lands characterized by low soil moisture availability and/or high salinity, we assess the potential productivity and economic benefits of CAM plants. CAM productivity is estimated using a recently developed model which simulates CAM photosynthesis under a range of soil and climate conditions. From these results, we compare the energy and water resource inputs required by CAM plants to those required by more traditional C3 and C4 crops (corn, wheat, sorghum), and we evaluate the economic potential of CAM crops as sources of food, fodder, or biofuel in marginal soils. As precipitation events become more intense and infrequent, we show that even though marginal land area may increase, CAM crop cultivation shows great promise for maintaining high productivity with minimal water inputs. Our analysis indicates that on marginal lands, widespread cultivation of CAM crops as biofuel feedstock may help

  5. Classification of CAM use and its correlates in patients with early-stage breast cancer.

    PubMed

    Saquib, Juliann; Madlensky, Lisa; Kealey, Sheila; Saquib, Nazmus; Natarajan, Loki; Newman, Vicky A; Patterson, Ruth E; Pierce, John P

    2011-06-01

    Self-reported use of complementary and alternative medicine (CAM) has been shown to increase following a cancer diagnosis, and breast cancer survivors are the heaviest users among cancer survivors. The aim of this study was to determine whether the prevalence estimate of CAM use varied according to classification of CAM. The authors used a comprehensive system to classify CAM users and test differences in demographic, lifestyle, quality of life, and cancer characteristics among them. Participants were 2562 breast cancer survivors participating in the Women's Healthy Eating and Living (WHEL) Study, aged 28 to 74 years. A structured telephone interview assessed CAM use, questioning about specific CAM practices, and whether use was related to cancer. This study examined CAM use in relation to demographics, health behaviors, and quality of life. Approximately 80% of the women used CAM for general purposes but only 50% reported CAM use for cancer purposes. Visual imagery, spiritual healing, and meditation were the most frequently used practices for cancer purposes. CAM use, defined as consulting a CAM practitioner and regular use, was significantly related to younger age, higher education, increased fruit and vegetable intake, and lower body mass index (P < .05). CAM users who had seen a practitioner were also more likely to report poor physical and mental health than non-CAM users (P < .05). CAM use was not associated with changes in physical and mental health between study baseline and 1-year follow-up. This study addressed important differences in the classification of CAM use among breast cancer survivors. Future studies need to further test the potential benefits and risks associated with CAM use.

  6. Safety Modification of Cam-and-Groove Hose Coupling

    NASA Technical Reports Server (NTRS)

    Schwindt, Paul; Littlefield, Alan

    2008-01-01

    A modification has been made in the mating halves of a cam-and-groove hose coupling to prevent rapid separation of the halves in the event that the cam levers are released while the fluid in the hose is pressurized. The need for this modification arises because commercial off-the-shelf cam-and-groove hose-coupling halves do not incorporate safety features to prevent separation in the pressurized state. Especially when the pressurized fluid is compressible (e.g., steam or compressed air), the separated halves can be propelled with considerable energy, causing personal injury and/or property damage. Therefore, one purpose served by the modification is to provide for venting to release compressive energy in a contained and safe manner while preventing personal injury and/or property damage. Another purpose served by the modification, during the process of connecting the coupling halves, is to ensure that the coupling halves are properly aligned before the cam levers can be locked into position.

  7. Numerical Control/Computer Aided Manufacturing (NC/CAM), A Descom Study

    DTIC Science & Technology

    1979-07-01

    CAM machines operate directly from computers, but most get instructions in the form of punched tape. The applications of NC/CAM are virtually...Although most NC/CAM equipment is metal working, its applications include electronics manufacturing, glass making, food processing, materiel handling...drafting, woodworking, plastics and inspection, just to name a few. Numerical control, like most technologies, is an advancing and evolutionary process

  8. The Confusion Assessment Method (CAM): A Systematic Review of Current Usage

    PubMed Central

    Wei, Leslie A.; Fearing, Michael A.; Sternberg, Eliezer J.; Inouye, Sharon K.

    2008-01-01

    Objectives To examine the psychometric properties, adaptations, translations, and applications of the Confusion Assessment Method (CAM), a widely-used instrument and diagnostic algorithm for identification of delirium. Design Systematic literature review Setting NA Measurements Electronic searches of PubMED, EMBASE, PsychINFO, CINAHL, Ageline, and Google Scholar, augmented by reviews of reference listings, were conducted to identify original English-language articles utilizing the CAM from January 1, 1991 to December 31, 2006. Two reviewers independently abstracted key information from each article. Participants NA Results Of 239 original articles, 10 (4%) were categorized as validation studies, 16 (7%) as adaptations; 12 (5%) as translations, and 222 (93%) as applications. Validation studies evaluated performance of the CAM against a reference standard. Results were combined across 7 high quality studies (n=1071), demonstrating an overall sensitivity of 94% (95% confidence interval, CI, 91–97%), and specificity of 89% (95% CI, 85–94%). CAM has been adapted for use in ICU, emergency, and institutional settings, and for scoring severity and subsyndromal delirium. CAM has been translated into 10 languages where published articles are available. In application studies, CAM-rated delirium is most commonly used as a risk factor or outcome, but also as an intervention or reference standard. Conclusions The CAM has helped to improve identification of delirium in clinical and research settings. To optimize performance, the CAM should be scored based on observations made during formal cognitive testing, and training is recommended. Future action is needed to optimize use of the CAM and to improve the recognition and management of delirium. PMID:18384586

  9. Enrichment, Isolation and Molecular Characterization of EpCAM-Negative Circulating Tumor Cells.

    PubMed

    Lampignano, Rita; Schneck, Helen; Neumann, Martin; Fehm, Tanja; Neubauer, Hans

    2017-01-01

    The presence of EpCAM-positive circulating tumor cells (CTCs) in the peripheral blood is associated with poor clinical outcomes in breast, colorectal and prostate cancer, as well as the prognosis of other tumor types. In addition, recent studies have suggested that the presence of CTCs undergoing epithelial-to-mesenchymal transition and, as such, may exhibit reduced or no expression of epithelial proteins e.g. EpCAM, might be related to disease progression in metastatic breast cancer (MBC) patients. Analyzing the neoplastic nature of this EpCAM-low/negative (EpCAM-neg) subpopulation remains an open issue as the current standard detection methods for CTCs are not efficient at identifying this subpopulation of cells. The possible association of EpCAM-neg CTCs with EpCAM-positive (EpCAM-pos) CTCs and role in the clinicopathological features and prognosis of MBC patients has still to be demonstrated. Several technologies have been developed and are currently being tested for the identification and the downstream analyses of EpCAM-pos CTCs. These technologies can be adapted and implemented into workflows to isolate and investigate EpCAM-neg cells to understand their biology and clinical relevance. This chapter will endeavour to explain the rationale behind the identification and analyses of all CTC subgroups, as well as to review the current strategies employed to enrich, isolate and characterize EpCAM-negative CTCs. Finally, the latest findings in the field will briefly be discussed with regard to their clinical relevance.

  10. NICMOS Focus and HST Breathing

    NASA Astrophysics Data System (ADS)

    Suchkov, A.; Hershey, J.

    1998-09-01

    The program 7608 monitored on a biweekly basis NICMOS camera foci from June 9, 1997, through February 18, 1998. Each of the biweekly observations included 17 measurements of focus position (focus sweeps), individually for each of the three cameras. The measurements for camera 1 and camera 3 foci covered one or two HST orbital periods. Comparison of these measurements with the predictions of the three OTA focus breathing models has shown the following. (1). Focus variations seen in NICMOS focus sweeps correlate well with the OTA focus thermal breathing as predicted by breathing models (“4- temperature”, “full-temperature”, and “attitude” models). Thus they can be attributed mostly to the HST orbital temperature variation. (2). The amount of breathing (breathing amplitude) has been found to be on average larger in the first orbit after a telescope slew to a new target. This is explained as being due to additional thermal perturbations caused by the change in the HST attitude as the telescope repoints to a new target. (3). In the first orbit, the amount of focus change predicted by the 4-temperature model is about the same as that seen in the focus sweeps data (breathing scale factor ~1). However the full-temperature model predicts a two times smaller breathing amplitude (breathing scale factor ~1.7). This suggests that the light shield temperatures are more responsive to the attitude change than temperatures from the other temperature sensors. The results of this study may help to better understand the HST thermal cycles and to improve the models describing the impact of those on both the OTA and NICMOS focus.

  11. Georeferencing CAMS data: Polynomial rectification and beyond

    NASA Astrophysics Data System (ADS)

    Yang, Xinghe

    The Calibrated Airborne Multispectral Scanner (CAMS) is a sensor used in the commercial remote sensing program at NASA Stennis Space Center. In geographic applications of the CAMS data, accurate geometric rectification is essential for the analysis of the remotely sensed data and for the integration of the data into Geographic Information Systems (GIS). The commonly used rectification techniques such as the polynomial transformation and ortho rectification have been very successful in the field of remote sensing and GIS for most remote sensing data such as Landsat imagery, SPOT imagery and aerial photos. However, due to the geometric nature of the airborne line scanner which has high spatial frequency distortions, the polynomial model and the ortho rectification technique in current commercial software packages such as Erdas Imagine are not adequate for obtaining sufficient geometric accuracy. In this research, the geometric nature, especially the major distortions, of the CAMS data has been described. An analytical step-by-step geometric preprocessing has been utilized to deal with the potential high frequency distortions of the CAMS data. A generic sensor-independent photogrammetric model has been developed for the ortho-rectification of the CAMS data. Three generalized kernel classes and directional elliptical basis have been formulated into a rectification model of summation of multisurface functions, which is a significant extension to the traditional radial basis functions. The preprocessing mechanism has been fully incorporated into the polynomial, the triangle-based finite element analysis as well as the summation of multisurface functions. While the multisurface functions and the finite element analysis have the characteristics of localization, piecewise logic has been applied to the polynomial and photogrammetric methods, which can produce significant accuracy improvement over the global approach. A software module has been implemented with full

  12. Angle assessment by EyeCam, goniophotography, and gonioscopy.

    PubMed

    Baskaran, Mani; Perera, Shamira A; Nongpiur, Monisha E; Tun, Tin A; Park, Judy; Kumar, Rajesh S; Friedman, David S; Aung, Tin

    2012-09-01

    To compare EyeCam (Clarity Medical Systems, Pleasanton, CA) and goniophotography in detecting angle closure, using gonioscopy as the reference standard. In this hospital-based, prospective, cross-sectional study, participants underwent gonioscopy by a single observer, and EyeCam imaging and goniophotography by different operators. The anterior chamber angle in a quadrant was classified as closed if the posterior trabecular meshwork could not be seen. A masked observer categorized the eyes as per the number of closed quadrants, and an eye was classified as having angle closure if there were 2 or more quadrants of closure. Agreement between the methods was analyzed by κ statistic and comparison of area under receiver operating characteristic curves (AUC). Eighty-five participants (85 eyes) were included, the majority of whom were Chinese. Angle closure was detected in 38 eyes (45%) with gonioscopy, 40 eyes (47%) using EyeCam, and 40 eyes (47%) with goniophotography (P=0.69 in both comparisons, McNemar test). The agreement for angle closure diagnosis (by eye) between gonioscopy and the 2 imaging modalities was high (κ=0.86; 95% Confidence Interval (CI), 0.75-0.97), whereas the agreement between EyeCam and goniophotography was not as good (κ=0.72; 95% CI, 0.57-0.87); largely due to lack of agreement in the nasal and temporal quadrants (κ=0.55 to 0.67). The AUC for detecting eyes with gonioscopic angle closure was similar for goniophotography and EyeCam (AUC 0.93, sensitivity=94.7%, specificity=91.5%; P>0.95). EyeCam and goniophotography have similarly high sensitivity and specificity for the detection of gonioscopic angle closure.

  13. Use of EyeCam for imaging the anterior chamber angle.

    PubMed

    Perera, Shamira A; Baskaran, Mani; Friedman, David S; Tun, Tin A; Htoon, Hla M; Kumar, Rajesh S; Aung, Tin

    2010-06-01

    To compare EyeCam (Clarity Medical Systems, Pleasanton, CA) imaging with gonioscopy for detecting angle closure. In this prospective, hospital-based study, subjects underwent gonioscopy by a single observer and EyeCam imaging by a different operator. EyeCam images were graded by two masked observers. The anterior chamber angle in a quadrant was classified as closed if the trabecular meshwork could not be seen. The eye was classified as having angle closure if two or more quadrants were closed. One hundred fifty-two subjects were studied. The mean age was 57.4 years (SD 12.9) and there were 82 (54%) men. Of the 152 eyes, 21 (13.8%) had angle closure. The EyeCam provided clear images of the angles in 98.8% of subjects. The agreement between the EyeCam and gonioscopy for detecting angle closure in the superior, inferior, nasal, and temporal quadrants based on agreement coefficient (AC1) statistics was 0.73, 0.75, 0.76, and 0.72, respectively. EyeCam detected more closed angles than did gonioscopy in all quadrants (P < 0.05). With gonioscopy, 21/152 (13.8%) eyes were diagnosed as angle closure compared to 41 (27.0%) of 152 with EyeCam (P < 0.001, McNemar Test), giving an overall sensitivity of 76.2% (95% confidence interval [CI], 54.9%-90.7%), specificity of 80.9% (95%CI, 73.5%-87.3%), and an area under the receiver operating characteristic curve (AUC) of 0.79. The EyeCam showed good agreement with gonioscopy for detecting angle closure. However, it detected more closed angles than did gonioscopy in all quadrants.

  14. Pinhole Cameras: For Science, Art, and Fun!

    ERIC Educational Resources Information Center

    Button, Clare

    2007-01-01

    A pinhole camera is a camera without a lens. A tiny hole replaces the lens, and light is allowed to come in for short amount of time by means of a hand-operated shutter. The pinhole allows only a very narrow beam of light to enter, which reduces confusion due to scattered light on the film. This results in an image that is focused, reversed, and…

  15. Rationale for the Use of CAD/CAM Technology in Implant Prosthodontics

    PubMed Central

    Abduo, Jaafar; Lyons, Karl

    2013-01-01

    Despite the predictable longevity of implant prosthesis, there is an ongoing interest to continue to improve implant prosthodontic treatment and outcomes. One of the developments is the application of computer-aided design and computer-aided manufacturing (CAD/CAM) to produce implant abutments and frameworks from metal or ceramic materials. The aim of this narrative review is to critically evaluate the rationale of CAD/CAM utilization for implant prosthodontics. To date, CAD/CAM allows simplified production of precise and durable implant components. The precision of fit has been proven in several laboratory experiments and has been attributed to the design of implants. Milling also facilitates component fabrication from durable and aesthetic materials. With further development, it is expected that the CAD/CAM protocol will be further simplified. Although compelling clinical evidence supporting the superiority of CAD/CAM implant restorations is still lacking, it is envisioned that CAD/CAM may become the main stream for implant component fabrication. PMID:23690778

  16. iPhone 4s and iPhone 5s Imaging of the Eye

    PubMed Central

    Jalil, Maaz; Ferenczy, Sandor R.; Shields, Carol L.

    2017-01-01

    Background/Aims To evaluate the technical feasibility of a consumer-grade cellular iPhone camera as an ocular imaging device compared to existing ophthalmic imaging equipment for documentation purposes. Methods A comparison of iPhone 4s and 5s images was made with external facial images (macrophotography) using Nikon cameras, slit-lamp images (microphotography) using Zeiss photo slit-lamp camera, and fundus images (fundus photography) using RetCam II. Results In an analysis of six consecutive patients with ophthalmic conditions, both iPhones achieved documentation of external findings (macrophotography) using standard camera modality, tap to focus, and built-in flash. Both iPhones achieved documentation of anterior segment findings (microphotography) during slit-lamp examination through oculars. Both iPhones achieved fundus imaging using standard video modality with continuous iPhone illumination through an ophthalmic lens. Comparison to standard ophthalmic cameras, macrophotography and microphotography were excellent. In comparison to RetCam fundus photography, iPhone fundus photography revealed smaller field and was technically more difficult to obtain, but the quality was nearly similar to RetCam. Conclusions iPhone versions 4s and 5s can provide excellent ophthalmic macrophotography and microphotography and adequate fundus photography. We believe that iPhone imaging could be most useful in settings where expensive, complicated, and cumbersome imaging equipment is unavailable. PMID:28275604

  17. Temporal and spatial transcriptomic and microRNA dynamics of CAM photosynthesis in pineapple.

    PubMed

    Wai, Ching M; VanBuren, Robert; Zhang, Jisen; Huang, Lixian; Miao, Wenjing; Edger, Patrick P; Yim, Won C; Priest, Henry D; Meyers, Blake C; Mockler, Todd; Smith, J Andrew C; Cushman, John C; Ming, Ray

    2017-10-01

    The altered carbon assimilation pathway of crassulacean acid metabolism (CAM) photosynthesis results in an up to 80% higher water-use efficiency than C 3 photosynthesis in plants making it a potentially useful pathway for engineering crop plants with improved drought tolerance. Here we surveyed detailed temporal (diel time course) and spatial (across a leaf gradient) gene and microRNA (miRNA) expression patterns in the obligate CAM plant pineapple [Ananas comosus (L.) Merr.]. The high-resolution transcriptome atlas allowed us to distinguish between CAM-related and non-CAM gene copies. A differential gene co-expression network across green and white leaf diel datasets identified genes with circadian oscillation, CAM-related functions, and source-sink relations. Gene co-expression clusters containing CAM pathway genes are enriched with clock-associated cis-elements, suggesting circadian regulation of CAM. About 20% of pineapple microRNAs have diel expression patterns, with several that target key CAM-related genes. Expression and physiology data provide a model for CAM-specific carbohydrate flux and long-distance hexose transport. Together these resources provide a list of candidate genes for targeted engineering of CAM into C 3 photosynthesis crop species. © 2017 The Authors The Plant Journal © 2017 John Wiley & Sons Ltd.

  18. Refocusing distance of a standard plenoptic camera.

    PubMed

    Hahne, Christopher; Aggoun, Amar; Velisavljevic, Vladan; Fiebig, Susanne; Pesch, Matthias

    2016-09-19

    Recent developments in computational photography enabled variation of the optical focus of a plenoptic camera after image exposure, also known as refocusing. Existing ray models in the field simplify the camera's complexity for the purpose of image and depth map enhancement, but fail to satisfyingly predict the distance to which a photograph is refocused. By treating a pair of light rays as a system of linear functions, it will be shown in this paper that its solution yields an intersection indicating the distance to a refocused object plane. Experimental work is conducted with different lenses and focus settings while comparing distance estimates with a stack of refocused photographs for which a blur metric has been devised. Quantitative assessments over a 24 m distance range suggest that predictions deviate by less than 0.35 % in comparison to an optical design software. The proposed refocusing estimator assists in predicting object distances just as in the prototyping stage of plenoptic cameras and will be an essential feature in applications demanding high precision in synthetic focus or where depth map recovery is done by analyzing a stack of refocused photographs.

  19. Camera calibration for multidirectional flame chemiluminescence tomography

    NASA Astrophysics Data System (ADS)

    Wang, Jia; Zhang, Weiguang; Zhang, Yuhong; Yu, Xun

    2017-04-01

    Flame chemiluminescence tomography (FCT), which combines computerized tomography theory and multidirectional chemiluminescence emission measurements, can realize instantaneous three-dimensional (3-D) diagnostics for flames with high spatial and temporal resolutions. One critical step of FCT is to record the projections by multiple cameras from different view angles. For high accuracy reconstructions, it requires that extrinsic parameters (the positions and orientations) and intrinsic parameters (especially the image distances) of cameras be accurately calibrated first. Taking the focus effect of the camera into account, a modified camera calibration method was presented for FCT, and a 3-D calibration pattern was designed to solve the parameters. The precision of the method was evaluated by reprojections of feature points to cameras with the calibration results. The maximum root mean square error of the feature points' position is 1.42 pixels and 0.0064 mm for the image distance. An FCT system with 12 cameras was calibrated by the proposed method and the 3-D CH* intensity of a propane flame was measured. The results showed that the FCT system provides reasonable reconstruction accuracy using the camera's calibration results.

  20. The Effects of End-of-Day Picture Review and a Sensor-based Picture Capture Procedure on Autobiographical Memory using SenseCam

    PubMed Central

    Finley, Jason R.; Brewer, William F.; Benjamin, Aaron S.

    2011-01-01

    Emerging “life-logging” technologies have tremendous potential to augment human autobiographical memory by recording and processing vast amounts of information from an individual’s experiences. In this experiment undergraduate participants wore a SenseCam, a small, sensor-equipped digital camera, as they went about their normal daily activities for five consecutive days. Pictures were captured either at fixed intervals or as triggered by SenseCam’s sensors. On two of five nights, participants watched an end-of-day review of a random subset of pictures captured that day. Participants were tested with a variety of memory measures at intervals of 1, 3, and 8 weeks. The most fruitful of six measures were recognition rating (on a 1–7 scale) and picture-cued recall length. On these tests, end-of-day review enhanced performance relative to no review, while pictures triggered by SenseCam’s sensors showed little difference in performance compared to those taken at fixed time intervals. We discuss the promise of SenseCam as a tool for research and for improving autobiographical memory. PMID:21229457

  1. Family Medicine Residency Program Directors Attitudes and Knowledge of Family Medicine CAM Competencies

    PubMed Central

    Gardiner, Paula; Filippelli, Amanda C.; Lebensohn, Patricia; Bonakdar, Robert

    2013-01-01

    Context Little is known about the incorporation of integrative medicine (IM) and complementary and alternative medicine (CAM) into family medicine residency programs. Objective The Society for Teachers of Family Medicine (STFM) approved a set of CAM/IM competencies for family medicine residencies. We hope to evaluate with an online survey tool, whether residency programs are implementing such competencies into their curriculum. We also hope to assess the knowledge and attitudes of Residency Directors (RDs) on the CAM/IM competencies. Design A survey was distributed by the CAFM (Council of Academic Family Medicine) Educational Research Alliance to RDs via email. The survey was distributed to 431 RDs. Of those who received it, 212 responded for a response rate of 49.1%. Questions assessed the knowledge and attitudes of CAM/IM competencies and incorporation of CAM/IM into residency curriculum. Results Forty-five percent of RDs were aware of the competencies. In term of RD attitudes, 58% reported that CAM/IM is an important component of residents' curriculum yet, 60% report not having specific learning objectives for CAM/IM in their residency curriculum. Among all programs, barriers to CAM/IM implementation included: time in residents' schedules (77%); faculty training (75%); access to CAM experts (43%); lack of reimbursement (43%), and financial resources (29%). Conclusions While many RDs are aware of the STFM CAM/IM competencies and acknowledge their role in residence education, there are many barriers preventing residencies to implementing the STFM CAM/IM competencies. PMID:24021471

  2. False CAM alarms from radon fluctuations.

    PubMed

    Hayes, Robert

    2003-11-01

    The root cause of many false continuous air monitor (CAM) alarms is revealed for CAMs that use constant spectral shape assumptions in transuranic (TRU) alpha activity determination algorithms. This paper shows that when atmospheric radon levels continually decrease and bottom out at a minimum level, reduced false TRU count rates are not only expected but measured. Similarly, when the radon levels continually increase to a maximum level, elevated false TRU count rates were measured as predicted. The basis for expecting this dependence on changes in radon levels is discussed.

  3. Management of CAD/CAM information: Key to improved manufacturing productivity

    NASA Technical Reports Server (NTRS)

    Fulton, R. E.; Brainin, J.

    1984-01-01

    A key element to improved industry productivity is effective management of CAD/CAM information. To stimulate advancements in this area, a joint NASA/Navy/Industry project designated Integrated Programs for Aerospace-Vehicle Design (IPAD) is underway with the goal of raising aerospace industry productivity through advancement of technology to integrate and manage information involved in the design and manufacturing process. The project complements traditional NASA/DOD research to develop aerospace design technology and the Air Force's Integrated Computer-Aided Manufacturing (ICAM) program to advance CAM technology. IPAD research is guided by an Industry Technical Advisory Board (ITAB) composed of over 100 repesentatives from aerospace and computer companies. The IPAD accomplishments to date in development of requirements and prototype software for various levels of company-wide CAD/CAM data management are summarized and plans for development of technology for management of distributed CAD/CAM data and information required to control future knowledge-based CAD/CAM systems are discussed.

  4. Accuracy Analysis for Automatic Orientation of a Tumbling Oblique Viewing Sensor System

    NASA Astrophysics Data System (ADS)

    Stebner, K.; Wieden, A.

    2014-03-01

    Dynamic camera systems with moving parts are difficult to handle in photogrammetric workflow, because it is not ensured that the dynamics are constant over the recording period. Minimum changes of the camera's orientation greatly influence the projection of oblique images. In this publication these effects - originating from the kinematic chain of a dynamic camera system - are analysed and validated. A member of the Modular Airborne Camera System family - MACS-TumbleCam - consisting of a vertical viewing and a tumbling oblique camera was used for this investigation. Focus is on dynamic geometric modeling and the stability of the kinematic chain. To validate the experimental findings, the determined parameters are applied to the exterior orientation of an actual aerial image acquisition campaign using MACS-TumbleCam. The quality of the parameters is sufficient for direct georeferencing of oblique image data from the orientation information of a synchronously captured vertical image dataset. Relative accuracy for the oblique data set ranges from 1.5 pixels when using all images of the image block to 0.3 pixels when using only adjacent images.

  5. Thermal infrared data of active lava surfaces using a newly-developed camera system

    NASA Astrophysics Data System (ADS)

    Thompson, J. O.; Ramsey, M. S.

    2017-12-01

    Our ability to acquire accurate data during lava flow emplacement greatly improves models designed to predict their dynamics and down-flow hazard potential. For example, better constraint on the physical property of emissivity as a lava cools improves the accuracy of the derived temperature, a critical parameter for flow models that estimate at-vent eruption rate, flow length, and distribution. Thermal infrared (TIR) data are increasingly used as a tool to determine eruption styles and cooling regimes by measuring temperatures at high temporal resolutions. Factors that control the accurate measurement of surface temperatures include both material properties (e.g., emissivity and surface texture) as well as external factors (e.g., camera geometry and the intervening atmosphere). We present a newly-developed, field-portable miniature multispectral thermal infrared camera (MMT-Cam) to measure both temperature and emissivity of basaltic lava surfaces at up to 7 Hz. The MMT-Cam acquires emitted radiance in six wavelength channels in addition to the broadband temperature. The instrument was laboratory calibrated for systematic errors and fully field tested at the Overlook Crater lava lake (Kilauea, HI) in January 2017. The data show that the major emissivity absorption feature (around 8.5 to 9.0 µm) transitions to higher wavelengths and the depth of the feature decreases as a lava surface cools, forming a progressively thicker crust. This transition occurs over a temperature range of 758 to 518 K. Constraining the relationship between this spectral change and temperature derived from this data will provide more accurate temperatures and therefore, more accurate modeling results. This is the first time that emissivity and its link to temperature has been measured in situ on active lava surfaces, which will improve input parameters of flow propagation models and possibly improve flow forecasting.

  6. Use of CAM in local African-American communities: community-partnered research.

    PubMed Central

    Barnett, Marina C.; Cotroneo, Margaret; Purnell, Joseph; Martin, Danielle; Mackenzie, Elizabeth; Fishman, Alfred

    2003-01-01

    Although previous national surveys have shown an increase in the use of complementary and alternative medicine (CAM) in the U.S. population, racial and ethnic minority populations were under-represented in these surveys. As a result, a profile of the CAM user as white, female, affluent, middle-aged and well educated has emerged. Representing the mainstream population, these previous studies did not take into account the racial and ethnic minority populations who may have their own healing traditions and who may hold different beliefs, use different terminology, and have unique patterns of CAM use. In partnership with community-based organizations and community residents, a culturally sensitive survey instrument and protocols were designed and tested to gather data on lower income, urban African-Americans' use of, attitudes toward, and understanding of CAM. The major findings of this pilot research are 1.) Community-partnered research can help researchers gain access to sensitive data and design culturally appropriate studies; 2.) CAM terminology varies by cultural group; 3.) Certain forms of CAM (folk or family practices) are commonly found in African-American populations; and 4.) Factors that affect CAM use--including age, lack of access to conventional medicine, cultural heritage, and dissatisfaction with conventional medicine. PMID:14620706

  7. Comparative evaluation of RetCam vs. gonioscopy images in congenital glaucoma.

    PubMed

    Azad, Raj V; Chandra, Parijat; Chandra, Anuradha; Gupta, Aparna; Gupta, Viney; Sihota, Ramanjit

    2014-02-01

    To compare clarity, exposure and quality of anterior chamber angle visualization in congenital glaucoma patients, using RetCam and indirect gonioscopy images. Cross-sectional study Participants. Congenital glaucoma patients over age of 5 years. A prospective consecutive pilot study was done in congenital glaucoma patients who were older than 5 years. Methods used are indirect gonioscopy and RetCam imaging. Clarity of the image, extent of angle visible and details of angle structures seen were graded for both methods, on digitally recorded images, in each eye, by two masked observers. Image clarity, interobserver agreement. 40 eyes of 25 congenital glaucoma patients were studied. RetCam image had excellent clarity in 77.5% of patients versus 47.5% by gonioscopy. The extent of angle seen was similar by both methods. Agreement between RetCam and gonioscopy images regarding details of angle structures was 72.50% by observer 1 and 65.00% by observer 2. There was good agreement between RetCam and indirect gonioscopy images in detecting angle structures of congenital glaucoma patients. However, RetCam provided greater clarity, with better quality, and higher magnification images. RetCam can be a useful alternative to gonioscopy in infants and small children without the need for general anesthesia.

  8. Camera systems in human motion analysis for biomedical applications

    NASA Astrophysics Data System (ADS)

    Chin, Lim Chee; Basah, Shafriza Nisha; Yaacob, Sazali; Juan, Yeap Ewe; Kadir, Aida Khairunnisaa Ab.

    2015-05-01

    Human Motion Analysis (HMA) system has been one of the major interests among researchers in the field of computer vision, artificial intelligence and biomedical engineering and sciences. This is due to its wide and promising biomedical applications, namely, bio-instrumentation for human computer interfacing and surveillance system for monitoring human behaviour as well as analysis of biomedical signal and image processing for diagnosis and rehabilitation applications. This paper provides an extensive review of the camera system of HMA, its taxonomy, including camera types, camera calibration and camera configuration. The review focused on evaluating the camera system consideration of the HMA system specifically for biomedical applications. This review is important as it provides guidelines and recommendation for researchers and practitioners in selecting a camera system of the HMA system for biomedical applications.

  9. CAD/CAM: Practical and Persuasive in Canadian Schools

    ERIC Educational Resources Information Center

    Willms, Ed

    2007-01-01

    Chances are that many high school students would not know how to use drafting instruments, but some might want to gain competence in computer-assisted design (CAD) and possibly computer-assisted manufacturing (CAM). These students are often attracted to tech courses by the availability of CAD/CAM instructions, and many go on to impress employers…

  10. Energy considerations in the Community Atmosphere Model (CAM)

    DOE PAGES

    Williamson, David L.; Olson, Jerry G.; Hannay, Cécile; ...

    2015-06-30

    An error in the energy formulation in the Community Atmosphere Model (CAM) is identified and corrected. Ten year AMIP simulations are compared using the correct and incorrect energy formulations. Statistics of selected primary variables all indicate physically insignificant differences between the simulations, comparable to differences with simulations initialized with rounding sized perturbations. The two simulations are so similar mainly because of an inconsistency in the application of the incorrect energy formulation in the original CAM. CAM used the erroneous energy form to determine the states passed between the parameterizations, but used a form related to the correct formulation for themore » state passed from the parameterizations to the dynamical core. If the incorrect form is also used to determine the state passed to the dynamical core the simulations are significantly different. In addition, CAM uses the incorrect form for the global energy fixer, but that seems to be less important. The difference of the magnitude of the fixers using the correct and incorrect energy definitions is very small.« less

  11. Complementary and Alternative Medicine (CAM) Treatments and Pediatric Psychopharmacology

    ERIC Educational Resources Information Center

    Rey, Joseph M.; Walter, Garry; Soh, Nerissa

    2008-01-01

    Children and adolescents often use complementary and alternative medicine (CAM) treatments outside their indications, particularly to lose weight. Some of the herbal remedies and dietary supplements that may of relevance for psychopharmacological practice are discussed with respect to CAM treatments.

  12. Single lens 3D-camera with extended depth-of-field

    NASA Astrophysics Data System (ADS)

    Perwaß, Christian; Wietzke, Lennart

    2012-03-01

    Placing a micro lens array in front of an image sensor transforms a normal camera into a single lens 3D camera, which also allows the user to change the focus and the point of view after a picture has been taken. While the concept of such plenoptic cameras is known since 1908, only recently the increased computing power of low-cost hardware and the advances in micro lens array production, have made the application of plenoptic cameras feasible. This text presents a detailed analysis of plenoptic cameras as well as introducing a new type of plenoptic camera with an extended depth of field and a maximal effective resolution of up to a quarter of the sensor resolution.

  13. Examining CAM use disclosure using the Behavioral Model of Health Services Use.

    PubMed

    Faith, Jennifer; Thorburn, Sheryl; Tippens, Kimberly M

    2013-10-01

    To improve understanding of factors that may influence disclosure of complementary and alternative medicine (CAM) use in the U.S. Cross-sectional survey. Data are from the 2001 Health Care Quality Survey (HCQS), a nationally representative study of adults aged 18 and older living in the continental United States. Using the Behavioral Model of Health Services Use, we conducted multivariate logistic regressions to identify factors associated with disclosing CAM use among the sub-sample of recent CAM users (n=1995). Disclosure of CAM use. Most CAM users (71.0%) disclosed their use of CAM to their doctors. Contextual, individual, and health behavior factors were associated with CAM use disclosure. Of particular interest, disclosure was significantly more likely among those who perceived high quality relationships with their providers (AOR=1.59, CI: 1.01, 2.49) and among those who had a regular source of medical care (AOR=1.54, CI: 1.03, 2.29). The odds of disclosure were also higher among those who used practitioner-provided CAM, with (AOR=2.02, CI: 1.34, 3.06) or without (AOR=1.52, CI: 1.05, 2.20) concurrent herbal medicine use, compared to those who used herbal medicines only. The Behavioral Model of Health Services Use is a useful framework for examining factors that may influence disclosure of CAM use. Further research should examine these relationships using more comprehensive measures. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. Special Section: Complementary and Alternative Medicine (CAM): Low Back Pain and CAM

    MedlinePlus

    ... back, he has used conventional and complementary and alternative medicine (CAM) approaches, including regular visits to the chiropractor and massage therapist to address his pain. "I'm looking for something so that I don't ... with other alternative and traditional therapies to help them resume normal ...

  15. SatCam: A mobile application for coordinated ground/satellite observation of clouds and validation of satellite-derived cloud mask products.

    NASA Astrophysics Data System (ADS)

    Gumley, L.; Parker, D.; Flynn, B.; Holz, R.; Marais, W.

    2011-12-01

    SatCam is an application for iOS devices that allows users to collect observations of local cloud and surface conditions in coordination with an overpass of the Terra, Aqua, or NPP satellites. SatCam allows users to acquire images of sky conditions and ground conditions at their location anywhere in the world using the built-in iPhone or iPod Touch camera at the same time that the satellite is passing overhead and viewing their location. Immediately after the sky and ground observations are acquired, the application asks the user to rate the level of cloudiness in the sky (Completely Clear, Mostly Clear, Partly Cloudy, Overcast). For the ground observation, the user selects their assessment of the surface conditions (Urban, Green Vegetation, Brown Vegetation, Desert, Snow, Water). The sky condition and surface condition selections are stored along with the date, time, and geographic location for the images, and the images are uploaded to a central server. When the MODIS (Terra and Aqua) or VIIRS (NPP) imagery acquired over the user location becomes available, a MODIS or VIIRS true color image centered at the user's location is delivered back to the SatCam application on the user's iOS device. SSEC also proposes to develop a community driven SatCam website where users can share their observations and assessments of satellite cloud products in a collaborative environment. SSEC is developing a server side data analysis system to ingest the SatCam user observations, apply quality control, analyze the sky images for cloud cover, and collocate the observations with MODIS and VIIRS satellite products (e.g., cloud mask). For each observation that is collocated with a satellite observation, the server will determine whether the user scored a "hit", meaning their sky observation and sky assessment matched the automated cloud mask obtained from the satellite observation. The hit rate will be an objective assessment of the accuracy of the user's sky observations. Users with

  16. Family medicine residency program directors attitudes and knowledge of family medicine CAM competencies.

    PubMed

    Gardiner, Paula; Filippelli, Amanda C; Lebensohn, Patricia; Bonakdar, Robert

    2013-01-01

    Little is known about the incorporation of integrative medicine (IM) and complementary and alternative medicine (CAM) into family medicine residency programs. The Society for Teachers of Family Medicine (STFM) approved a set of CAM/IM competencies for family medicine residencies. We hope to evaluate whether residency programs are implementing such competencies into their curriculum using an online survey tool. We also hope to assess the knowledge and attitudes of Residency Directors (RDs) on the CAM/IM competencies. A survey was distributed by the Council of Academic Family Medicine (CAFM) Educational Research Alliance to RDs via e-mail. The survey was distributed to 431 RDs. Of those who received it, 212 responded, giving a response rate of 49.1%. Questions assessed the knowledge and attitudes of CAM/IM competencies and incorporation of CAM/IM into the residency curriculum. Forty-five percent of RDs were aware of the competencies. In terms of RD attitudes, 58% reported that CAM/IM is an important component of residents' curriculum; yet, 60% report not having specific learning objectives for CAM/IM in their residency curriculum. Among all programs, barriers to CAM/IM implementation included time in residents' schedules (77%); faculty training (75%); access to CAM experts (43%); lack of reimbursement (43%); and financial resources (29%). While many RDs are aware of the STFM CAM/IM competencies and acknowledge their role in residence education, there are many barriers that prevent residencies from implementing the STFM CAM/IM competencies. © 2013 Elsevier Inc. All rights reserved.

  17. Complementary and Alternative Medicine (CAM) and Next-Generation CAM (NG-CAM) Strategies for Therapeutic Gut Microbiota Modulation in Inflammatory Bowel Disease

    PubMed Central

    Basson, Abigail R; Minh, Lam; Cominelli, Fabio

    2018-01-01

    SUMMARY The human gastrointestinal tract is resident to a vastly diverse microbial consortium that co-exists through strict rules of invasion, dominance, resilience and succession. While some members possess stronger capabilities for survival than others, each one retains a genome characteristic of their bacterial denomination which subsequently determines survival and ultimately the composition of a human gut microbiome. Collective evidence advocates the concept of gut microbiota modulation via dietary compounds, with or without nutraceutical supplementation. However, consistent reports of strong individuality in responsiveness suggest that initial composition of host microbiota mediates the effect of nutrition modulation. There is also a strong potential for the interaction between mind and microbe to influence responsiveness, although mechanistic understanding of these complex exchanges remains in its infancy at best. Synthetic stool for FMT is a next-generation microbiome-therapy shown effective in treating C.difficile [417] which could provide a feasible alternative to current methods for patients with IBD. Nevertheless, studies investigating optimum timing for FMT administration are essential. Animal and human studies are only starting to highlight the Pandora of interactions that endure between members of gut microbiome, their associated metabolites, dietary compounds, as well as host neurological and immune systems, all of which characteristic to each individual. Advanced research technologies have excelled the scientific evidence in support of CAM and toward generating NG-CAM systems designed for treatment of specific disease states, such as IBD. While the majority of envisioned NG-CAM strategies presently exist in their experimental and discovery phases, many show promise for future clinical application. PMID:29173517

  18. Pattern and predictors of complementary and alternative medicine (CAM) use among pediatric patients with epilepsy.

    PubMed

    Doering, Jan H; Reuner, Gitta; Kadish, Navah E; Pietz, Joachim; Schubert-Bast, Susanne

    2013-10-01

    Parents of pediatric patients with chronic conditions such as epilepsy increasingly opt for complementary and alternative medicine (CAM). However, data on the pattern and reasons of CAM use in childhood epilepsy are scarce. The objectives of this study were as follows: first, to characterize CAM use among pediatric patients with epilepsy by assessing its spectrum, prevalence, costs, and frequency of use; second, to evaluate the influence of CAM use on compliance and satisfaction with conventional care as well as to explore parent-child neurologist communication concerning CAM; and third, to investigate predictors of CAM use. A postal survey was administered to all parents of pediatric outpatients with epilepsy aged 6 to 12, who have received treatment at the neuropediatric outpatient clinic of the University Children's Hospital Heidelberg between 2007 and 2009. One hundred thirty-two of the 297 distributed questionnaires were suitable for inclusion in statistical analysis (44.7%). Forty-nine participants indicated that their children used CAM during the previous year (37.1%). Thirty different types of CAM were used, with homeopathy (55.1%), osteopathy (24.5%), and kinesiology (16.3%) being the most commonly named. A mean of 86€ (0€-500€) and 3h (1 h-30 h) per month was committed to CAM treatment. Only 53% of the users informed their child neurologist of the additional CAM treatment, while 85.6% of all parents wished to discuss CAM options with their child neurologist. Seventy-five percent of users considered the CAM treatment effective. Among the participants most likely to seek CAM treatment are parents whose children show a long duration of epileptic symptoms, parents who make use of CAM treatment themselves, and parents who value a holistic and natural treatment approach. A substantial portion of pediatric patients with epilepsy receive CAM treatment. The high prevalence of use and significant level of financial and time resources spent on CAM indicate the

  19. Experimentally induced cam impingement in the sheep hip.

    PubMed

    Siebenrock, Klaus A; Fiechter, Ruth; Tannast, Moritz; Mamisch, Tallal C; von Rechenberg, Brigitte

    2013-04-01

    Sheep hips have a natural non-spherical femoral head similar to a cam-type deformity in human beings. By performing an intertrochanteric varus osteotomy, cam-type femoro-acetabular impingement (FAI) during flexion can be created. We tested the hypotheses that macroscopic lesions of the articular cartilage and an increased Mankin score (MS) can be reproduced by an experimentally induced cam-type FAI in this ovine in vivo model. Furthermore, we hypothesized that the MS increases with longer ambulatory periods. Sixteen sheep underwent unilateral intertrochanteric varus osteotomy of the hip with the non-operated hip as a control. Four sheep were sacrificed after 14, 22, 30, and 38-weeks postoperatively. We evaluated macroscopic chondrolabral alterations, and recorded the MS, based on histochemical staining, for each ambulatory period. A significantly higher prevalence of macroscopic chondrolabral lesions was found in the impingement zone of the operated hips. The MS was significantly higher in the acetabular/femoral cartilage of the operated hips. Furthermore, these scores increased as the length of the ambulatory period increased. Cam-type FAI can be induced in an ovine in vivo model. Localized chondrolabral degeneration of the hip, similar to that seen in humans (Tannast et al., Clin Orthop Relat Res 2008; 466: 273-280; Beck et al., J Bone Joint Surg Br 2005; 87: 1012-1018), can be reproduced. This experimental sheep model can be used to study cam-type FAI. Copyright © 2012 Orthopaedic Research Society.

  20. Fiber-optical switch using cam-micromotor driven by scratch drive actuators

    NASA Astrophysics Data System (ADS)

    Kanamori, Y.; Aoki, Y.; Sasaki, M.; Hosoya, H.; Wada, A.; Hane, K.

    2005-01-01

    We fabricated a 1 × 1 fiber-optic switch using a cam-micromotor driven by scratch drive actuators (SDAs). Using the cam-micromotor, mechanical translation and precise positioning of an optical fiber were performed. An optical fiber of diameter 50 µm was bent and pushed out with a cam-mechanism driven by the SDAs fabricated by surface micromachining. The maximum rotation speed of the cam-micromotor was 7.5 rpm at a driving frequency of 1.5 kHz. The transient time of the switch to attenuate coupling efficiency less than -40 dB was around 10 ms.

  1. Plenoptic camera image simulation for reconstruction algorithm verification

    NASA Astrophysics Data System (ADS)

    Schwiegerling, Jim

    2014-09-01

    Plenoptic cameras have emerged in recent years as a technology for capturing light field data in a single snapshot. A conventional digital camera can be modified with the addition of a lenslet array to create a plenoptic camera. Two distinct camera forms have been proposed in the literature. The first has the camera image focused onto the lenslet array. The lenslet array is placed over the camera sensor such that each lenslet forms an image of the exit pupil onto the sensor. The second plenoptic form has the lenslet array relaying the image formed by the camera lens to the sensor. We have developed a raytracing package that can simulate images formed by a generalized version of the plenoptic camera. Several rays from each sensor pixel are traced backwards through the system to define a cone of rays emanating from the entrance pupil of the camera lens. Objects that lie within this cone are integrated to lead to a color and exposure level for that pixel. To speed processing three-dimensional objects are approximated as a series of planes at different depths. Repeating this process for each pixel in the sensor leads to a simulated plenoptic image on which different reconstruction algorithms can be tested.

  2. CAM: A high-performance cellular-automaton machine

    NASA Astrophysics Data System (ADS)

    Toffoli, Tommaso

    1984-01-01

    CAM is a high-performance machine dedicated to the simulation of cellular automata and other distributed dynamical systems. Its speed is about one-thousand times greater than that of a general-purpose computer programmed to do the same task; in practical terms, this means that CAM can show the evolution of cellular automata on a color monitor with an update rate, dynamic range, and spatial resolution comparable to those of a Super-8 movie, thus permitting intensive interactive experimentation. Machines of this kind can open up novel fields of research, and in this context it is important that results be easy to obtain, reproduce, and transmit. For these reasons, in designing CAM it was important to achieve functional simplicity, high flexibility, and moderate production cost. We expect that many research groups will be able to own their own copy of the machine to do research with.

  3. Transcript, protein and metabolite temporal dynamics in the CAM plant Agave

    DOE PAGES

    Abraham, Paul E.; Yin, Hengfu; Borland, Anne M.; ...

    2016-11-21

    Already a proven mechanism for drought resilience, crassulacean acid metabolism (CAM) is a specialized type of photosynthesis that maximizes water-use efficiency (WUE) via an inverse (compared to C 3 and C 4 photosynthesis-performing species) day/night pattern of stomatal closure/opening to shift CO 2 uptake to the night, when evapotranspiration rates are low. A systems-level understanding of temporal molecular and metabolic controls is needed to define the cellular behavior that underpins CAM. Here, we report high-resolution temporal behaviors of transcript, protein and metabolite abundances across a CAM diel cycle and, where applicable, compare those observations to the well-established C 3 modelmore » plant, Arabidopsis thaliana. A mechanistic finding that emerged is that CAM operates with a diel redox poise that is shifted relative to that in Arabidopsis thaliana. Moreover, we identified widespread rescheduled expression of genes associated with signal transduction mechanisms that regulate stomatal opening/closing. Controlled production and degradation of transcripts and proteins represents a timing mechanism by which to regulate cellular function, yet how this molecular timekeeping regulates CAM physiology remains unclear. In this paper, we provide new insights into complex post-transcriptional and -translational hierarchies that govern CAM in Agave. These data sets together provide a resource to inform efforts to engineer more water-use efficient CAM pathway traits into economically valuable C 3 crops.« less

  4. Transcript, protein and metabolite temporal dynamics in the CAM plant Agave

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abraham, Paul E.; Yin, Hengfu; Borland, Anne M.

    Already a proven mechanism for drought resilience, crassulacean acid metabolism (CAM) is a specialized type of photosynthesis that maximizes water-use efficiency (WUE) via an inverse (compared to C 3 and C 4 photosynthesis-performing species) day/night pattern of stomatal closure/opening to shift CO 2 uptake to the night, when evapotranspiration rates are low. A systems-level understanding of temporal molecular and metabolic controls is needed to define the cellular behavior that underpins CAM. Here, we report high-resolution temporal behaviors of transcript, protein and metabolite abundances across a CAM diel cycle and, where applicable, compare those observations to the well-established C 3 modelmore » plant, Arabidopsis thaliana. A mechanistic finding that emerged is that CAM operates with a diel redox poise that is shifted relative to that in Arabidopsis thaliana. Moreover, we identified widespread rescheduled expression of genes associated with signal transduction mechanisms that regulate stomatal opening/closing. Controlled production and degradation of transcripts and proteins represents a timing mechanism by which to regulate cellular function, yet how this molecular timekeeping regulates CAM physiology remains unclear. In this paper, we provide new insights into complex post-transcriptional and -translational hierarchies that govern CAM in Agave. These data sets together provide a resource to inform efforts to engineer more water-use efficient CAM pathway traits into economically valuable C 3 crops.« less

  5. Comparative evaluation of RetCam vs. gonioscopy images in congenital glaucoma

    PubMed Central

    Azad, Raj V; Chandra, Parijat; Chandra, Anuradha; Gupta, Aparna; Gupta, Viney; Sihota, Ramanjit

    2014-01-01

    Purpose: To compare clarity, exposure and quality of anterior chamber angle visualization in congenital glaucoma patients, using RetCam and indirect gonioscopy images. Design: Cross-sectional study Participants. Congenital glaucoma patients over age of 5 years. Materials and Methods: A prospective consecutive pilot study was done in congenital glaucoma patients who were older than 5 years. Methods used are indirect gonioscopy and RetCam imaging. Clarity of the image, extent of angle visible and details of angle structures seen were graded for both methods, on digitally recorded images, in each eye, by two masked observers. Outcome Measures: Image clarity, interobserver agreement. Results: 40 eyes of 25 congenital glaucoma patients were studied. RetCam image had excellent clarity in 77.5% of patients versus 47.5% by gonioscopy. The extent of angle seen was similar by both methods. Agreement between RetCam and gonioscopy images regarding details of angle structures was 72.50% by observer 1 and 65.00% by observer 2. Conclusions: There was good agreement between RetCam and indirect gonioscopy images in detecting angle structures of congenital glaucoma patients. However, RetCam provided greater clarity, with better quality, and higher magnification images. RetCam can be a useful alternative to gonioscopy in infants and small children without the need for general anesthesia. PMID:24008788

  6. VizieR Online Data Catalog: The M87 globular cluster system (Strader+, 2011)

    NASA Astrophysics Data System (ADS)

    Strader, J.; Romanowsky, A. J.; Brodie, J. P.; Spitler, L. R.; Beasley, M. A.; Arnold, J. A.; Tamura, N.; Sharples, R. M.; Arimoto, N.

    2012-01-01

    We selected GC candidates from the Subaru/Suprime-Cam imaging study of Tamura et al. (2006MNRAS.373..588T). Spectroscopic data were obtained from Keck/DEIMOS in 2007 Mar 20 and 21 and in 2010 Mar 12, from Keck/Low Resolution Spectrometer (LRIS) in 2010 Apr 8-11 and from Multiple Mirror Telescope (MMT)/Hectospec in 2010 Feb 17. We chose to use for our default GC photometry the new gri CFHT/Megacam imaging of M87 published in Harris (2009ApJ...703..939H). (9 data files).

  7. Incorporation of CAD/CAM Restoration Into Navy Dentistry

    DTIC Science & Technology

    2017-09-26

    CAD/CAM Computer-aided design /Computer-assisted manufacturing CDT Common Dental Terminology DENCAS Dental Common Access System DTF Dental...to reduce avoidable dental emergencies for deployed sailors and marines. Dental Computer-aided design /Computer-assisted manufacturing (CAD/CAM...report will review and evaluate the placement rate by Navy dentists of digitally fabricated in-office ceramic restorations compared to traditional direct

  8. Sky camera geometric calibration using solar observations

    DOE PAGES

    Urquhart, Bryan; Kurtz, Ben; Kleissl, Jan

    2016-09-05

    camera model and associated automated calibration procedure for stationary daytime sky imaging cameras is presented. The specific modeling and calibration needs are motivated by remotely deployed cameras used to forecast solar power production where cameras point skyward and use 180° fisheye lenses. Sun position in the sky and on the image plane provides a simple and automated approach to calibration; special equipment or calibration patterns are not required. Sun position in the sky is modeled using a solar position algorithm (requiring latitude, longitude, altitude and time as inputs). Sun position on the image plane is detected using a simple image processing algorithm. Themore » performance evaluation focuses on the calibration of a camera employing a fisheye lens with an equisolid angle projection, but the camera model is general enough to treat most fixed focal length, central, dioptric camera systems with a photo objective lens. Calibration errors scale with the noise level of the sun position measurement in the image plane, but the calibration is robust across a large range of noise in the sun position. In conclusion, calibration performance on clear days ranged from 0.94 to 1.24 pixels root mean square error.« less

  9. Evaluation of complementary-alternative medicine (CAM) questionnaire development for Indonesian clinical psychologists: A pilot study.

    PubMed

    Liem, Andrian; Newcombe, Peter A; Pohlman, Annie

    2017-08-01

    This study aimed to evaluate questionnaire development to measure the knowledge of Complementary-Alternative Medicine (CAM), attitudes towards CAM, CAM experiences, and CAM educational needs of clinical psychologists in Indonesia. A 26-item questionnaire was developed through an extensive literature search. Data was obtained from provisional psychologists from the Master of Professional Clinical Psychology programs at two established public universities in urban areas of Indonesia. To validate the questionnaire, panel reviews by executive members of the Indonesian Clinical Psychology Association (ICPA), experts in health psychology, and experts in public health and CAM provided their professional judgements. The self-reporting questionnaire consisted of four scales including: knowledge of CAM (6 items), attitudes towards CAM (10 items), CAM experiences (4 items), and CAM educational needs (6 items). All scales, except CAM Experiences, were assessed on a 7-point Likert scale. Sixty provisional psychologists were eligible to complete the questionnaire with a response rate of 73% (N=44). The results showed that the CAM questionnaire was reliable (Cronbach's coefficient alpha range=0.62-0.96; item-total correlation range=0.14-0.92) and demonstrated content validity. Following further psychometric evaluation, the CAM questionnaire may provide the evidence-based information to inform the education and practice of Indonesian clinical psychologists. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Evolution of CAM and C4 carbon-concentrating mechanisms

    USGS Publications Warehouse

    Keeley, Jon E.; Rundel, Philip W.

    2003-01-01

    Mechanisms for concentrating carbon around the Rubisco enzyme, which drives the carbon-reducing steps in photosynthesis, are widespread in plants; in vascular plants they are known as crassulacean acid metabolism (CAM) and C4 photosynthesis. CAM is common in desert succulents, tropical epiphytes, and aquatic plants and is characterized by nighttime fixation of CO2. The proximal selective factor driving the evolution of this CO2-concentrating pathway is low daytime CO2, which results from the unusual reverse stomatal behavior of terrestrial CAM species or from patterns of ambient CO2 availability for aquatic CAM species. In terrestrials the ultimate selective factor is water stress that has selected for increased water use efficiency. In aquatics the ultimate selective factor is diel fluctuations in CO2 availability for palustrine species and extreme oligotrophic conditions for lacustrine species. C4 photosynthesis is based on similar biochemistry but carboxylation steps are spatially separated in the leaf rather than temporally as in CAM. This biochemical pathway is most commonly associated with a specialized leaf anatomy known as Kranz anatomy; however, there are exceptions. The ultimate selective factor driving the evolution of this pathway is excessively high photorespiration that inhibits normal C3 photosynthesis under high light and high temperature in both terrestrial and aquatic habitats. CAM is an ancient pathway that likely has been present since the Paleozoic era in aquatic species from shallow-water palustrine habitats. While atmospheric CO2 levels have undoubtedly affected the evolution of terrestrial plant carbon-concentrating mechanisms, there is reason to believe that past atmospheric changes have not played as important a selective role in the aquatic milieu since palustrine habitats today are not generally carbon sinks, and the selective factors driving aquatic CAM are autogenic. Terrestrial CAM, in contrast, is of increasing selective value under

  11. Applying Principles from Complex Systems to Studying the Efficacy of CAM Therapies

    PubMed Central

    Nahin, Richard L.; Calabrese, Carlo; Folkman, Susan; Kimbrough, Elizabeth; Shoham, Jacob; Haramati, Aviad

    2010-01-01

    Abstract In October 2007, a National Center for Complementary and Alternative Medicine (NCCAM)–sponsored workshop, entitled “Applying Principles from Complex Systems to Studying the Efficacy of CAM Therapies,” was held at Georgetown University in Washington, DC. Over a 2-day period, the workshop engaged a small group of experts from the fields of complementary and alternative medicine (CAM) research and complexity science to discuss and examine ways in which complexity science can be applied to CAM research. After didactic presentations and small-group discussions, a number of salient themes and ideas emerged. This paper article describes the workshop program and summarizes these emergent ideas, which are divided into five broad categories: (1) introduction to complexity; (2) challenges to CAM research; (3) applications of complexity science to CAM; (4) CAM as a model of complexity applied to medicine; and (5) future directions. This discusses possible benefits and challenges associated with applying complexity science to CAM research. By providing an introductory framework for this collaboration and exchange, it is hoped that this article may stimulate further inquiry into this largely unexplored area of research. PMID:20715978

  12. Automatic inference of geometric camera parameters and inter-camera topology in uncalibrated disjoint surveillance cameras

    NASA Astrophysics Data System (ADS)

    den Hollander, Richard J. M.; Bouma, Henri; Baan, Jan; Eendebak, Pieter T.; van Rest, Jeroen H. C.

    2015-10-01

    Person tracking across non-overlapping cameras and other types of video analytics benefit from spatial calibration information that allows an estimation of the distance between cameras and a relation between pixel coordinates and world coordinates within a camera. In a large environment with many cameras, or for frequent ad-hoc deployments of cameras, the cost of this calibration is high. This creates a barrier for the use of video analytics. Automating the calibration allows for a short configuration time, and the use of video analytics in a wider range of scenarios, including ad-hoc crisis situations and large scale surveillance systems. We show an autocalibration method entirely based on pedestrian detections in surveillance video in multiple non-overlapping cameras. In this paper, we show the two main components of automatic calibration. The first shows the intra-camera geometry estimation that leads to an estimate of the tilt angle, focal length and camera height, which is important for the conversion from pixels to meters and vice versa. The second component shows the inter-camera topology inference that leads to an estimate of the distance between cameras, which is important for spatio-temporal analysis of multi-camera tracking. This paper describes each of these methods and provides results on realistic video data.

  13. Climate-resilient agroforestry: physiological responses to climate change and engineering of crassulacean acid metabolism (CAM) as a mitigation strategy: CAM engineering in trees

    DOE PAGES

    Borland, Anne M.; Wullschleger, Stan D.; Weston, David J.; ...

    2014-12-15

    We know that global climate change threatens the sustainability of agriculture and agroforestry worldwide through increased heat, drought, surface evaporation and associated soil drying. Exposure of crops and forests to warmer and drier environments will increase leaf:air water vapour–pressure deficits (VPD), and will result in increased drought susceptibility and reduced productivity, not only in arid regions but also in tropical regions with seasonal dry periods. Fast-growing, short-rotation forestry (SRF) bioenergy crops such as poplar (Populus spp.) and willow (Salix spp.) are particularly susceptible to hydraulic failure following drought stress due to their isohydric nature and relatively high stomatal conductance. Onemore » approach to sustaining plant productivity is to improve water-use efficiency (WUE) by engineering crassulacean acid metabolism (CAM) into C3 crops. CAM improves WUE by shifting stomatal opening and primary CO 2 uptake and fixation to the night-time when leaf:air VPD is low. CAMmembers of the tree genus Clusia exemplify the compatibility of CAM performance within tree species and highlight CAM as a mechanism to conserve water and maintain carbon uptake during drought conditions. Moreover, the introduction of bioengineered CAM into SRF bioenergy trees is a potentially viable path to sustaining agroforestry production systems in the face of a globally changing climate.« less

  14. Climate-resilient agroforestry: physiological responses to climate change and engineering of crassulacean acid metabolism (CAM) as a mitigation strategy: CAM engineering in trees

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Borland, Anne M.; Wullschleger, Stan D.; Weston, David J.

    We know that global climate change threatens the sustainability of agriculture and agroforestry worldwide through increased heat, drought, surface evaporation and associated soil drying. Exposure of crops and forests to warmer and drier environments will increase leaf:air water vapour–pressure deficits (VPD), and will result in increased drought susceptibility and reduced productivity, not only in arid regions but also in tropical regions with seasonal dry periods. Fast-growing, short-rotation forestry (SRF) bioenergy crops such as poplar (Populus spp.) and willow (Salix spp.) are particularly susceptible to hydraulic failure following drought stress due to their isohydric nature and relatively high stomatal conductance. Onemore » approach to sustaining plant productivity is to improve water-use efficiency (WUE) by engineering crassulacean acid metabolism (CAM) into C3 crops. CAM improves WUE by shifting stomatal opening and primary CO 2 uptake and fixation to the night-time when leaf:air VPD is low. CAMmembers of the tree genus Clusia exemplify the compatibility of CAM performance within tree species and highlight CAM as a mechanism to conserve water and maintain carbon uptake during drought conditions. Moreover, the introduction of bioengineered CAM into SRF bioenergy trees is a potentially viable path to sustaining agroforestry production systems in the face of a globally changing climate.« less

  15. Survey of UK dentists regarding the use of CAD/CAM technology.

    PubMed

    Tran, D; Nesbit, M; Petridis, H

    2016-11-18

    Statement of the problem Digital workflows (CAD/CAM) have been introduced in dentistry during recent years. No published information exists on dentists' use and reporting of this technology.Purpose The purpose of this survey was to identify the infiltration of CAD/CAM technology in UK dental practices and to investigate the relationship of various demographic factors to the answers regarding use or non-use of this technology.Materials and methods One thousand and thirty-one online surveys were sent to a sample of UK dentists composing of both users and non-users of CAD/CAM. It aimed to reveal information regarding type of usage, materials, perceived benefits, barriers to access, and disadvantages of CAD/CAM dentistry. Statistical analysis was undertaken to test the influence of various demographic variables such as country of work, dentist experience, level of training and type of work (NHS or private).Results The number of completed responses totalled 385. Most of the respondents did not use any part of a digital workflow, and the main barriers to CAD/CAM use were initial costs and a lack of perceived benefit over conventional methods. Dentists delivering mostly private work were most likely to have adopted CAD/CAM technology (P <0.001). Further training also correlated with a greater likelihood of CAD/CAM usage (P <0.001). Most users felt that the technology had led to a change in the use of dental materials, leading to increased use of, for example, zirconia and lithium disilicate. Most users were trained either by companies or self-trained, and a third felt that their training was insufficient. The majority of respondents (89%) felt that CAD/CAM had a big role to play in the future.Conclusion Most of the respondents did not use any part of a digital workflow. However, the majority of surveyed dentists were interested in incorporating CAD/CAM into their workflow, while most believed that it will have a big role in the future. There are still some concerns from

  16. Fracture strength testing of crowns made of CAD/CAM composite resins.

    PubMed

    Okada, Ryota; Asakura, Masaki; Ando, Akihiro; Kumano, Hirokazu; Ban, Seiji; Kawai, Tatsushi; Takebe, Jun

    2018-03-28

    The purpose of this study was to ascertain whether computer aided design/computer aided manufacturing (CAD/CAM) composite resin crowns have sufficient strength to withstand the bite force of the molar teeth. The null hypothesis was that the fracture strength of CAD/CAM composite resin crowns is lower than the average maximum bite force of the molar tooth. The crowns, which shape is the right maxillary first molar, were fabricated using four CAD/CAM blanks made of composite resins (Block HC: HC, KZR-CAD HR: HR, KZR-CAD HR2: HR2, Avencia Block: AVE) and one CAD/CAM blank made of lithium disilicate glass-ceramic (IPS e.max CAD: IPS), which was used as a control. Fracture strength of fabricated crowns bonded to metal abutment and biaxial flexural strength of the materials were evaluated. The results of fracture strength test and biaxial flexural strength test showed different tendencies. The fracture strength of CAD/CAM composite resin crowns except HC ranged from 3.3kN to 3.9kN, and was similar to that of IPS (3.3kN). In contrast, biaxial flexural strength of CAD/CAM composite resins ranged from 175MPa to 247MPa, and was significantly lower than that of IPS (360MPa). All CAD/CAM composite resin crowns studied presented about 3-4 times higher fracture strength than the average maximum bite force of the molar tooth (700-900N), which result leads to the conclusion that CAD/CAM composite resin crowns would have sufficient strength to withstand the bite force of the molar teeth. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  17. Focus adjustment method for CBERS 3 and 4 satellites Mux camera to be performed in air condition and its experimental verification for best performance in orbital vacuum condition

    NASA Astrophysics Data System (ADS)

    Scaduto, Lucimara C. N.; Malavolta, Alexandre T.; Modugno, Rodrigo G.; Vales, Luiz F.; Carvalho, Erica G.; Evangelista, Sérgio; Stefani, Mario A.; de Castro Neto, Jarbas C.

    2017-11-01

    The first Brazilian remote sensing multispectral camera (MUX) is currently under development at Opto Eletronica S.A. It consists of a four-spectral-band sensor covering a 450nm to 890nm wavelength range. This camera will provide images within a 20m ground resolution at nadir. The MUX camera is part of the payload of the upcoming Sino-Brazilian satellites CBERS 3&4 (China-Brazil Earth Resource Satellite). The preliminary alignment between the optical system and the CCD sensor, which is located at the focal plane assembly, was obtained in air condition, clean room environment. A collimator was used for the performance evaluation of the camera. The preliminary performance evaluation of the optical channel was registered by compensating the collimator focus position due to changes in the test environment, as an air-to-vacuum environment transition leads to a defocus process in this camera. Therefore, it is necessary to confirm that the alignment of the camera must always be attained ensuring that its best performance is reached for an orbital vacuum condition. For this reason and as a further step on the development process, the MUX camera Qualification Model was tested and evaluated inside a thermo-vacuum chamber and submitted to an as-orbit vacuum environment. In this study, the influence of temperature fields was neglected. This paper reports on the performance evaluation and discusses the results for this camera when operating within those mentioned test conditions. The overall optical tests and results show that the "in air" adjustment method was suitable to be performed, as a critical activity, to guarantee the equipment according to its design requirements.

  18. Reasons for continuing use of Complementary and Alternative Medicine (CAM) in students: a consumer commitment model.

    PubMed

    Sirois, Fuschia M; Salamonsen, Anita; Kristoffersen, Agnete E

    2016-02-24

    Research on continued CAM use has been largely atheoretical and has not considered the broader range of psychological and behavioral factors that may be involved. The purpose of this study was to test a new conceptual model of commitment to CAM use that implicates utilitarian (trust in CAM) and symbolic (perceived fit with CAM) in psychological and behavioral dimensions of CAM commitment. A student sample of CAM consumers, (N = 159) completed a survey about their CAM use, CAM-related values, intentions for future CAM use, CAM word-of-mouth behavior, and perceptions of being an ongoing CAM consumer. Analysis revealed that the utilitarian, symbolic, and CAM commitment variables were significantly related, with r's ranging from .54 to .73. A series hierarchical regression analyses controlling for relevant demographic variables found that the utilitarian and symbolic values uniquely accounted for significant and substantial proportion of the variance in each of the three CAM commitment indicators (R(2) from .37 to .57). The findings provide preliminary support for the new model that posits that CAM commitment is a multi-dimensional psychological state with behavioral indicators. Further research with large-scale samples and longitudinal designs is warranted to understand the potential value of the new model.

  19. Effectiveness and efficiency of a CAD/CAM orthodontic bracket system.

    PubMed

    Brown, Matthew W; Koroluk, Lorne; Ko, Ching-Chang; Zhang, Kai; Chen, Mengqi; Nguyen, Tung

    2015-12-01

    The first straight-wire appliance was introduced over 40 years ago to increase the consistency and efficiency of orthodontic treatment. More recently, computer-aided design and computer-aided manufacturing (CAD/CAM) technology has been used to create individualized orthodontic appliances. The purpose of this study was to investigate the clinical effectiveness and efficiency of CAD/CAM customized orthodontic appliances compared with direct and indirect bonded stock orthodontic brackets. This retrospective study included 3 treatment groups: group 1 patients were direct bonded with self-ligating appliances, group 2 patients were indirect bonded with self-ligating appliances, and group 3 patients were indirect bonded with CAD/CAM self-ligating appliances. Complete pretreatment and posttreatment records were obtained for all patients. The American Board of Orthodontics (ABO) Discrepancy Index was used to evaluate the pretreatment records, and the posttreatment outcomes were analyzed using the ABO Cast-Radiograph Evaluation. All data collection and analysis were completed by 1 evaluator. There were no statistically significant differences in the ABO Discrepancy Index or the ABO Cast-Radiograph Evaluation among the groups. Treatment times for the 3 groups were significantly different; the CAD/CAM group was the shortest at 13.8 ± 3.4 months, compared with 21.9 ± 5.0 and 16.9 ± 4.1 months for the direct bonded and indirect bonded groups, respectively. The number of treatment appointments for the CAD/CAM group was significantly fewer than for the direct bonded group. The CAD/CAM orthodontic bracket system evaluated in this study was as effective in treatment outcome measures as were standard brackets bonded both directly and indirectly. The CAD/CAM appliance was more efficient in regard to treatment duration, although the decrease in total archwire appointments was minimal. Further investigation is needed to better quantify the clinical benefits of CAD/CAM orthodontic

  20. Distributed Energy Resources Customer Adoption Model Plus (DER-CAM+), Version 1.0.0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stadler, Michael; Cardorso, Goncalo; Mashayekh, Salman

    DER-CAM+ v1.0.0 is internally referred to as DER-CAM v5.0.0. Due to fundamental changes from previous versions, a new name (DER-CAM+) will be used for DER-CAM version 5.0.0 and above. DER-CAM+ is a Decision Support Tool for Decentralized Energy Systems that has been tailored for microgrid applications, and now explicitly considers electrical and thermal networks within a microgrid, ancillary services, and operating reserve. DER-CAM was initially created as an exclusively economic energy model, able to find the cost minimizing combination and operation profile of a set of DER technologies that meet energy loads of a building or microgrid for a typicalmore » test year. The previous versions of DER-CAM were formulated without modeling the electrical/thermal networks within the microgrid, and hence, used aggregate single-node approaches. Furthermore, they were not able to consider operating reserve constraints, and microgrid revenue streams from participating in ancillary services markets. This new version DER-CAM+ considers these issues by including electrical power flow and thermal flow equations and constraints in the microgrid, revenues from various ancillary services markets, and operating reserve constraints.« less

  1. Overview of Digital Forensics Algorithms in Dslr Cameras

    NASA Astrophysics Data System (ADS)

    Aminova, E.; Trapeznikov, I.; Priorov, A.

    2017-05-01

    The widespread usage of the mobile technologies and the improvement of the digital photo devices getting has led to more frequent cases of falsification of images including in the judicial practice. Consequently, the actual task for up-to-date digital image processing tools is the development of algorithms for determining the source and model of the DSLR (Digital Single Lens Reflex) camera and improve image formation algorithms. Most research in this area based on the mention that the extraction of unique sensor trace of DSLR camera could be possible on the certain stage of the imaging process into the camera. It is considered that the study focuses on the problem of determination of unique feature of DSLR cameras based on optical subsystem artifacts and sensor noises.

  2. Effect of Crystallization Firing on Marginal Gap of CAD/CAM Fabricated Lithium Disilicate Crowns.

    PubMed

    Gold, Steven A; Ferracane, Jack L; da Costa, Juliana

    2018-01-01

    To evaluate the marginal gaps of CAD/CAM (CEREC 3) produced crowns made from leucite-reinforced glass-ceramic (IPS Empress CAD) blocks (LG), and lithium-disilicate (IPS e.max CAD) blocks before (LD-B), and after (LD-A) crystallization firing. A human molar tooth (#19) was mounted with adjacent teeth on a typodont and prepared for a full-coverage ceramic crown. The typodont was assembled in the mannequin head to simulate clinical conditions. After tooth preparation 15 individual optical impressions were taken by the same operator using titanium dioxide powder and a CEREC 3 camera per manufacturer's instructions. One operator designed and machined the crowns in leucite-reinforced glass-ceramic blocks (n = 5) and lithium-disilicate blocks (n = 10) using the CEREC 3 system. The crowns were rigidly seated on the prepared tooth, and marginal gaps (μm) were measured with an optical microscope (500×) at 12 points, 3 on each of the M, B, D, and L surfaces of the leucite-reinforced glass-ceramic crowns and the lithium-disilicate crowns before and after crystallization firing. Results were analyzed by two-way ANOVA followed by a Tukey's post hoc multiple comparison test (α = 0.05). The overall mean marginal gaps (μm) for the crowns evaluated were: LG = 49.2 ± 5.5, LD-B = 42.9 ± 12.2, and LD-A = 57.2 ± 16.0. The marginal gaps for LG and LD-B were not significantly different, but both were significantly less than for LD-A. The type of ceramic material did not affect the marginal gap of CAD/CAM crowns. The crystallization firing process required for lithium-disilicate crowns resulted in a significant increase in marginal gap size, likely due to shrinkage of the ceramic during the crystallization process. The marginal gap of CAD/CAM-fabricated lithium disilicate crowns increases following crystallization firing. The marginal gap still remains within clinically acceptable parameters. © 2017 by the American College of Prosthodontists.

  3. CAM use in pediatric neurology: an exploration of concurrent use with conventional medicine.

    PubMed

    Galicia-Connolly, Elaine; Adams, Denise; Bateman, Justin; Dagenais, Simon; Clifford, Tammy; Baydala, Lola; King, W James; Vohra, Sunita

    2014-01-01

    Previous studies have found that up to 60% of children with neurologic conditions have tried complementary and alternative medicine (CAM). To assess the use of CAM among patients presenting to neurology clinics at two academic centers in Canada. A survey instrument was developed to inquire about use of CAM products and therapies, including reasons for use, perceived helpfulness, and concurrent use with conventional medicine, and administered to patients or their parents/guardians at the Stollery Children's Hospital in Edmonton and the Children's Hospital of Eastern Ontario (CHEO) in Ottawa. Overall CAM use at the Stollery was 78%, compared to 48% at CHEO. The most common CAM products used were multi-vitamins (84%), vitamin C (37%), homeopathic remedies (24%), and fish oil/omega 3 s (22%). The most common CAM practices used were massage (47%), chiropractic (37%), faith healing (18%), aromatherapy (16%), homeopathy (16%), and relaxation (16%). Many patients used CAM products at the same time as conventional medicine but just over half (57%) discussed this concurrent use with their physician. CAM use is common in pediatric neurology patients and most respondents felt that it was helpful, with few or no harms associated. However, this use is often undisclosed, increasing possibility of interactions with conventional drugs. We urge clinicians to inquire about CAM use during routine history taking at every patient visit. Parents would clearly like more information about CAM from their specialty clinics; such information would be easier to share if more primary data were available about the safety and effectiveness of commonly used therapies.

  4. CAM Use in Pediatric Neurology: An Exploration of Concurrent Use with Conventional Medicine

    PubMed Central

    Galicia-Connolly, Elaine; Adams, Denise; Bateman, Justin; Dagenais, Simon; Clifford, Tammy; Baydala, Lola; King, W. James; Vohra, Sunita

    2014-01-01

    Background Previous studies have found that up to 60% of children with neurologic conditions have tried complementary and alternative medicine (CAM). Objective To assess the use of CAM among patients presenting to neurology clinics at two academic centers in Canada. Methods A survey instrument was developed to inquire about use of CAM products and therapies, including reasons for use, perceived helpfulness, and concurrent use with conventional medicine, and administered to patients or their parents/guardians at the Stollery Children's Hospital in Edmonton and the Children's Hospital of Eastern Ontario (CHEO) in Ottawa. Results Overall CAM use at the Stollery was 78%, compared to 48% at CHEO. The most common CAM products used were multi-vitamins (84%), vitamin C (37%), homeopathic remedies (24%), and fish oil/omega 3 s (22%). The most common CAM practices used were massage (47%), chiropractic (37%), faith healing (18%), aromatherapy (16%), homeopathy (16%), and relaxation (16%). Many patients used CAM products at the same time as conventional medicine but just over half (57%) discussed this concurrent use with their physician. Conclusion CAM use is common in pediatric neurology patients and most respondents felt that it was helpful, with few or no harms associated. However, this use is often undisclosed, increasing possibility of interactions with conventional drugs. We urge clinicians to inquire about CAM use during routine history taking at every patient visit. Parents would clearly like more information about CAM from their specialty clinics; such information would be easier to share if more primary data were available about the safety and effectiveness of commonly used therapies. PMID:24736474

  5. Auto-converging stereo cameras for 3D robotic tele-operation

    NASA Astrophysics Data System (ADS)

    Edmondson, Richard; Aycock, Todd; Chenault, David

    2012-06-01

    Polaris Sensor Technologies has developed a Stereovision Upgrade Kit for TALON robot to provide enhanced depth perception to the operator. This kit previously required the TALON Operator Control Unit to be equipped with the optional touchscreen interface to allow for operator control of the camera convergence angle adjustment. This adjustment allowed for optimal camera convergence independent of the distance from the camera to the object being viewed. Polaris has recently improved the performance of the stereo camera by implementing an Automatic Convergence algorithm in a field programmable gate array in the camera assembly. This algorithm uses scene content to automatically adjust the camera convergence angle, freeing the operator to focus on the task rather than adjustment of the vision system. The autoconvergence capability has been demonstrated on both visible zoom cameras and longwave infrared microbolometer stereo pairs.

  6. Prevalence of cam hip shape morphology: a systematic review.

    PubMed

    Dickenson, E; Wall, P D H; Robinson, B; Fernandez, M; Parsons, H; Buchbinder, R; Griffin, D R

    2016-06-01

    Cam hip shape morphology is a recognised cause of femoroacetabular impingement (FAI) and is associated with hip osteoarthritis. Our aim was to systematically review the available epidemiological evidence assessing the prevalence of cam hip shape morphology in the general population and any studied subgroups including subjects with and without hip pain. All studies that reported the prevalence of cam morphology, measured by alpha angles, in subjects aged 18 and over, irrespective of study population or presence of hip symptoms were considered for inclusion. We searched AMED, MEDLINE, EMBASE, CINAHL and CENTRAL in October 2015. Two authors independently identified eligible studies and assessed risk of bias. We planned to pool data of studies considered clinically homogenous. Thirty studies met inclusion criteria. None of the included studies were truly population-based: three included non-representative subgroups of the general population, 19 included differing clinical populations, while eight included professional athletes. All studies were judged to be at high risk of bias. Due to substantial clinical heterogeneity meta analysis was not possible. Across all studies, the prevalence estimates of cam morphology ranged from 5 to 75% of participants affected. We were unable to demonstrate a higher prevalence in selected subgroups such as athletes or those with hip pain. There is currently insufficient high quality data to determine the true prevalence of cam morphology in the general population or selected subgroups. Well-designed population-based epidemiological studies that use homogenous case definitions are required to determine the prevalence of cam morphology and its relationship to hip pain. Copyright © 2016 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  7. The prevalence extent of Complementary and Alternative Medicine (CAM) use among Saudis.

    PubMed

    Alrowais, Norah A; Alyousefi, Nada A

    2017-03-01

    Introduction: There is worldwide interest in the use of CAM. Studying CAM in Saudi population is important as it will reflect the influence of psychosocial, cultural and religious factors on health beliefs and behaviors. The objective of this study was to present an updated review on the use of CAM practices in Saudi Arabia including commonly used types, common conditions for which it has been used and who uses CAM. Methods: This review used data from national surveys conducted in Saudi Arabia and published between 2000 and 2015. The literature search was performed considering standards adopted such as Moose guidelines for observational studies. Two authors independently reviewed each article. The search yielded 73 articles, and a total of 36 articles were included. Further careful data extraction was carried out by two independents reviewers. Results: Most of the reviewed studies were cross-sectional in design and were published between 2014 and 2015, and mostly in Riyadh region. Substantial difference in the findings for the patterns of CAM use was revealed. The most commonly employed practice was of spiritual type such as prayer and reciting Quran alone or on water. Other types include herbs (8-76%), honey (14-73%) and dietary products (6-82%). Cupping (Alhijamah) was least used (4-45%). Acupuncture was more practiced among professionals. Conclusion: The utilization of CAM is widely practiced in Saudi Arabia. There is need for efforts to promote research in the field of CAM to address each practice individually. Population surveys should be encouraged supported by mass media to raise knowledge and awareness about the practice of different CAM modalities. The national center of CAM should play a major role in these efforts.

  8. The Zwicky Transient Facility Camera

    NASA Astrophysics Data System (ADS)

    Dekany, Richard; Smith, Roger M.; Belicki, Justin; Delacroix, Alexandre; Duggan, Gina; Feeney, Michael; Hale, David; Kaye, Stephen; Milburn, Jennifer; Murphy, Patrick; Porter, Michael; Reiley, Daniel J.; Riddle, Reed L.; Rodriguez, Hector; Bellm, Eric C.

    2016-08-01

    The Zwicky Transient Facility Camera (ZTFC) is a key element of the ZTF Observing System, the integrated system of optoelectromechanical instrumentation tasked to acquire the wide-field, high-cadence time-domain astronomical data at the heart of the Zwicky Transient Facility. The ZTFC consists of a compact cryostat with large vacuum window protecting a mosaic of 16 large, wafer-scale science CCDs and 4 smaller guide/focus CCDs, a sophisticated vacuum interface board which carries data as electrical signals out of the cryostat, an electromechanical window frame for securing externally inserted optical filter selections, and associated cryo-thermal/vacuum system support elements. The ZTFC provides an instantaneous 47 deg2 field of view, limited by primary mirror vignetting in its Schmidt telescope prime focus configuration. We report here on the design and performance of the ZTF CCD camera cryostat and report results from extensive Joule-Thompson cryocooler tests that may be of broad interest to the instrumentation community.

  9. Complementary and Alternative Medicine (CAM): Expanding Horizons of Health Care

    MedlinePlus

    ... Past Issues Special Section CAM Expanding Horizons of Health Care Past Issues / Winter 2009 Table of Contents For ... and why it is important to tell your health care providers about your use of CAM. We hope ...

  10. A multi-criteria approach to camera motion design for volume data animation.

    PubMed

    Hsu, Wei-Hsien; Zhang, Yubo; Ma, Kwan-Liu

    2013-12-01

    We present an integrated camera motion design and path generation system for building volume data animations. Creating animations is an essential task in presenting complex scientific visualizations. Existing visualization systems use an established animation function based on keyframes selected by the user. This approach is limited in providing the optimal in-between views of the data. Alternatively, computer graphics and virtual reality camera motion planning is frequently focused on collision free movement in a virtual walkthrough. For semi-transparent, fuzzy, or blobby volume data the collision free objective becomes insufficient. Here, we provide a set of essential criteria focused on computing camera paths to establish effective animations of volume data. Our dynamic multi-criteria solver coupled with a force-directed routing algorithm enables rapid generation of camera paths. Once users review the resulting animation and evaluate the camera motion, they are able to determine how each criterion impacts path generation. In this paper, we demonstrate how incorporating this animation approach with an interactive volume visualization system reduces the effort in creating context-aware and coherent animations. This frees the user to focus on visualization tasks with the objective of gaining additional insight from the volume data.

  11. A Prospective, Multicenter Study of Complementary/Alternative Medicine (CAM) Utilization During Definitive Radiation for Breast Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moran, Meena S., E-mail: meena.moran@yale.edu; Department of Radiation Therapy, William W. Backus Hospital, Norwich, Connecticut; Ma Shuangge

    Purpose: Although complementary and alternative medicine (CAM) utilization in breast cancer patients is reported to be high, there are few data on CAM practices in breast patients specifically during radiation. This prospective, multi-institutional study was conducted to define CAM utilization in breast cancer during definitive radiation. Materials/Methods: A validated CAM instrument with a self-skin assessment was administered to 360 Stage 0-III breast cancer patients from 5 centers during the last week of radiation. All data were analyzed to detect significant differences between users/nonusers. Results: CAM usage was reported in 54% of the study cohort (n=194/360). Of CAM users, 71% reportedmore » activity-based CAM (eg, Reiki, meditation), 26% topical CAM, and 45% oral CAM. Only 16% received advice/counseling from naturopathic/homeopathic/medical professionals before initiating CAM. CAM use significantly correlated with higher education level (P<.001), inversely correlated with concomitant hormone/radiation therapy use (P=.010), with a trend toward greater use in younger patients (P=.066). On multivariate analysis, level of education (OR: 6.821, 95% CI: 2.307-20.168, P<.001) and hormones/radiation therapy (OR: 0.573, 95% CI: 0.347-0.949, P=.031) independently predicted for CAM use. Significantly lower skin toxicity scores were reported in CAM users vs nonusers, respectively (mild: 34% vs 25%, severe: 17% vs 29%, P=.017). Conclusion: This is the first prospective study to assess CAM practices in breast patients during radiation, with definition of these practices as the first step for future investigation of CAM/radiation interactions. These results should alert radiation oncologists that a large percentage of breast cancer patients use CAM during radiation without disclosure or consideration for potential interactions, and should encourage increased awareness, communication, and documentation of CAM practices in patients undergoing radiation treatment for

  12. The shed ectodomain of Nr-CAM stimulates cell proliferation and motility, and confers cell transformation.

    PubMed

    Conacci-Sorrell, Maralice; Kaplan, Anna; Raveh, Shani; Gavert, Nancy; Sakurai, Takeshi; Ben-Ze'ev, Avri

    2005-12-15

    Nr-CAM, a cell-cell adhesion molecule of the immunoglobulin-like cell adhesion molecule family, known for its function in neuronal outgrowth and guidance, was recently identified as a target gene of beta-catenin signaling in human melanoma and colon carcinoma cells and tissue. Retrovirally mediated transduction of Nr-CAM into fibroblasts induces cell motility and tumorigenesis. We investigated the mechanisms by which Nr-CAM can confer properties related to tumor cell behavior and found that Nr-CAM expression in NIH3T3 cells protects cells from apoptosis in the absence of serum by constitutively activating the extracellular signal-regulated kinase and AKT signaling pathways. We detected a metalloprotease-mediated shedding of Nr-CAM into the culture medium of cells transfected with Nr-CAM, and of endogenous Nr-CAM in B16 melanoma cells. Conditioned medium and purified Nr-CAM-Fc fusion protein both enhanced cell motility, proliferation, and extracellular signal-regulated kinase and AKT activation. Moreover, Nr-CAM was found in complex with alpha4beta1 integrins in melanoma cells, indicating that it can mediate, in addition to homophilic cell-cell adhesion, heterophilic adhesion with extracellular matrix receptors. Suppression of Nr-CAM levels by small interfering RNA in B16 melanoma inhibited the adhesive and tumorigenic capacities of these cells. Stable expression of the Nr-CAM ectodomain in NIH3T3 cells conferred cell transformation and tumorigenesis in mice, suggesting that the metalloprotease-mediated shedding of Nr-CAM is a principal route for promoting oncogenesis by Nr-CAM.

  13. Ceramic dental biomaterials and CAD/CAM technology: state of the art.

    PubMed

    Li, Raymond Wai Kim; Chow, Tak Wah; Matinlinna, Jukka Pekka

    2014-10-01

    Ceramics are widely used as indirect restorative materials in dentistry because of their high biocompatibility and pleasing aesthetics. The objective is to review the state of the arts of CAD/CAM all-ceramic biomaterials. CAD/CAM all-ceramic biomaterials are highlighted and a subsequent literature search was conducted for the relevant subjects using PubMed followed by manual search. Developments in CAD/CAM technology have catalyzed researches in all-ceramic biomaterials and their applications. Feldspathic glass ceramic and glass infiltrated ceramic can be fabricated by traditional laboratory methods or CAD/CAM. The advent of polycrystalline ceramics is a direct result of CAD/CAM technology without which the fabrication would not have been possible. The clinical uses of these ceramics have met with variable clinical success. Multiple options are now available to the clinicians for the fabrication of aesthetic all ceramic restorations. Copyright © 2014 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  14. Complementary and alternative medicine (CAM) use among hypertensive patients in Palestine.

    PubMed

    Ali-Shtayeh, Mohammed S; Jamous, Rana M; Jamous, Rania M; Salameh, Nihaya M Y

    2013-11-01

    To explore the frequency of CAM use among hypertensive patients in Palestine, determine demographic characteristics that may increase the likelihood of CAM use and to find out how benefits were perceived by patients. Across-sectional survey of patients attending outpatient hypertension clinics. The method was based on a semi-structured questionnaire. Of the 4575 hypertensive patients interviewed, 85.7% respondents used at least one type of CAM. Of the 3921 CAM users, 62.13% reported taking herbs. Most of these users were >50 years old, of low educational level, and had a family history of HTN, 62.9% claimed to have obtained the desired effect from taking these herbs; however, 68.1% did not disclose this fact to their health care providers, 83 plant taxa were reported by these patients, Allium sativum was the most commonly used herb. The use of CAM, particularly herbal therapies for hypertension treatment, is highly prevalent in Palestine. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Comparative fracture strength analysis of Lava and Digident CAD/CAM zirconia ceramic crowns

    PubMed Central

    Kwon, Taek-Ka; Pak, Hyun-Soon; Han, Jung-Suk; Lee, Jai-Bong; Kim, Sung-Hun

    2013-01-01

    PURPOSE All-ceramic crowns are subject to fracture during function. To minimize this common clinical complication, zirconium oxide has been used as the framework for all-ceramic crowns. The aim of this study was to compare the fracture strengths of two computer-aided design/computer-aided manufacturing (CAD/CAM) zirconia crown systems: Lava and Digident. MATERIALS AND METHODS Twenty Lava CAD/CAM zirconia crowns and twenty Digident CAD/CAM zirconia crowns were fabricated. A metal die was also duplicated from the original prepared tooth for fracture testing. A universal testing machine was used to determine the fracture strength of the crowns. RESULTS The mean fracture strengths were as follows: 54.9 ± 15.6 N for the Lava CAD/CAM zirconia crowns and 87.0 ± 16.0 N for the Digident CAD/CAM zirconia crowns. The difference between the mean fracture strengths of the Lava and Digident crowns was statistically significant (P<.001). Lava CAD/CAM zirconia crowns showed a complete fracture of both the veneering porcelain and the core whereas the Digident CAD/CAM zirconia crowns showed fracture only of the veneering porcelain. CONCLUSION The fracture strengths of CAD/CAM zirconia crowns differ depending on the compatibility of the core material and the veneering porcelain. PMID:23755332

  16. Comparative fracture strength analysis of Lava and Digident CAD/CAM zirconia ceramic crowns.

    PubMed

    Kwon, Taek-Ka; Pak, Hyun-Soon; Yang, Jae-Ho; Han, Jung-Suk; Lee, Jai-Bong; Kim, Sung-Hun; Yeo, In-Sung

    2013-05-01

    All-ceramic crowns are subject to fracture during function. To minimize this common clinical complication, zirconium oxide has been used as the framework for all-ceramic crowns. The aim of this study was to compare the fracture strengths of two computer-aided design/computer-aided manufacturing (CAD/CAM) zirconia crown systems: Lava and Digident. Twenty Lava CAD/CAM zirconia crowns and twenty Digident CAD/CAM zirconia crowns were fabricated. A metal die was also duplicated from the original prepared tooth for fracture testing. A universal testing machine was used to determine the fracture strength of the crowns. THE MEAN FRACTURE STRENGTHS WERE AS FOLLOWS: 54.9 ± 15.6 N for the Lava CAD/CAM zirconia crowns and 87.0 ± 16.0 N for the Digident CAD/CAM zirconia crowns. The difference between the mean fracture strengths of the Lava and Digident crowns was statistically significant (P<.001). Lava CAD/CAM zirconia crowns showed a complete fracture of both the veneering porcelain and the core whereas the Digident CAD/CAM zirconia crowns showed fracture only of the veneering porcelain. The fracture strengths of CAD/CAM zirconia crowns differ depending on the compatibility of the core material and the veneering porcelain.

  17. Connecting American Manufacturers (CAM) Virtual Manufacturing Marketplace (VMM)

    DTIC Science & Technology

    2013-11-01

    88ABW-2013-5037 1.0 SUMMARY The Connecting American Manufacturing (CAM) initiative was designed to improve the sourcing capability for Department...addition, CAM was designed to increase the number of US companies bidding on DoD business. The team’s overall approach was based on three major...is to designate a North American Industry Classification System (NAICS) code for each opportunity. Every manufacturing opportunity is posted to

  18. Uav Cameras: Overview and Geometric Calibration Benchmark

    NASA Astrophysics Data System (ADS)

    Cramer, M.; Przybilla, H.-J.; Zurhorst, A.

    2017-08-01

    Different UAV platforms and sensors are used in mapping already, many of them equipped with (sometimes) modified cameras as known from the consumer market. Even though these systems normally fulfil their requested mapping accuracy, the question arises, which system performs best? This asks for a benchmark, to check selected UAV based camera systems in well-defined, reproducible environments. Such benchmark is tried within this work here. Nine different cameras used on UAV platforms, representing typical camera classes, are considered. The focus is laid on the geometry here, which is tightly linked to the process of geometrical calibration of the system. In most applications the calibration is performed in-situ, i.e. calibration parameters are obtained as part of the project data itself. This is often motivated because consumer cameras do not keep constant geometry, thus, cannot be seen as metric cameras. Still, some of the commercial systems are quite stable over time, as it was proven from repeated (terrestrial) calibrations runs. Already (pre-)calibrated systems may offer advantages, especially when the block geometry of the project does not allow for a stable and sufficient in-situ calibration. Especially for such scenario close to metric UAV cameras may have advantages. Empirical airborne test flights in a calibration field have shown how block geometry influences the estimated calibration parameters and how consistent the parameters from lab calibration can be reproduced.

  19. Understanding dental CAD/CAM for restorations--accuracy from a mechanical engineering viewpoint.

    PubMed

    Tapie, Laurent; Lebon, Nicolas; Mawussi, Bernardin; Fron-Chabouis, Hélène; Duret, Francois; Attal, Jean-Pierre

    2015-01-01

    As is the case in the field of medicine, as well as in most areas of daily life, digital technology is increasingly being introduced into dental practice. Computer-aided design/ computer-aided manufacturing (CAD/CAM) solutions are available not only for chairside practice but also for creating inlays, crowns, fixed partial dentures (FPDs), implant abutments, and other dental prostheses. CAD/CAM dental practice can be considered as the handling of devices and software processing for the almost automatic design and creation of dental restorations. However, dentists who want to use dental CAD/CAM systems often do not have enough information to understand the variations offered by such technology practice. Knowledge of the random and systematic errors in accuracy with CAD/CAM systems can help to achieve successful restorations with this technology, and help with the purchasing of a CAD/CAM system that meets the clinical needs of restoration. This article provides a mechanical engineering viewpoint of the accuracy of CAD/ CAM systems, to help dentists understand the impact of this technology on restoration accuracy.

  20. Dual cameras acquisition and display system of retina-like sensor camera and rectangular sensor camera

    NASA Astrophysics Data System (ADS)

    Cao, Nan; Cao, Fengmei; Lin, Yabin; Bai, Tingzhu; Song, Shengyu

    2015-04-01

    For a new kind of retina-like senor camera and a traditional rectangular sensor camera, dual cameras acquisition and display system need to be built. We introduce the principle and the development of retina-like senor. Image coordinates transformation and interpolation based on sub-pixel interpolation need to be realized for our retina-like sensor's special pixels distribution. The hardware platform is composed of retina-like senor camera, rectangular sensor camera, image grabber and PC. Combined the MIL and OpenCV library, the software program is composed in VC++ on VS 2010. Experience results show that the system can realizes two cameras' acquisition and display.

  1. Application of phase matching autofocus in airborne long-range oblique photography camera

    NASA Astrophysics Data System (ADS)

    Petrushevsky, Vladimir; Guberman, Asaf

    2014-06-01

    The Condor2 long-range oblique photography (LOROP) camera is mounted in an aerodynamically shaped pod carried by a fast jet aircraft. Large aperture, dual-band (EO/MWIR) camera is equipped with TDI focal plane arrays and provides high-resolution imagery of extended areas at long stand-off ranges, at day and night. Front Ritchey-Chretien optics is made of highly stable materials. However, the camera temperature varies considerably in flight conditions. Moreover, a composite-material structure of the reflective objective undergoes gradual dehumidification in dry nitrogen atmosphere inside the pod, causing some small decrease of the structure length. The temperature and humidity effects change a distance between the mirrors by just a few microns. The distance change is small but nevertheless it alters the camera's infinity focus setpoint significantly, especially in the EO band. To realize the optics' resolution potential, the optimal focus shall be constantly maintained. In-flight best focus calibration and temperature-based open-loop focus control give mostly satisfactory performance. To get even better focusing precision, a closed-loop phase-matching autofocus method was developed for the camera. The method makes use of an existing beamsharer prism FPA arrangement where aperture partition exists inherently in an area of overlap between the adjacent detectors. The defocus is proportional to an image phase shift in the area of overlap. Low-pass filtering of raw defocus estimate reduces random errors related to variable scene content. Closed-loop control converges robustly to precise focus position. The algorithm uses the temperature- and range-based focus prediction as an initial guess for the closed-loop phase-matching control. The autofocus algorithm achieves excellent results and works robustly in various conditions of scene illumination and contrast.

  2. Bidirectional modulation of endogenous EpCAM expression to unravel its function in ovarian cancer

    PubMed Central

    van der Gun, B T F; Huisman, C; Stolzenburg, S; Kazemier, H G; Ruiters, M H J; Blancafort, P; Rots, M G

    2013-01-01

    Background: The epithelial cell adhesion molecule (EpCAM) is overexpressed on most carcinomas. Dependent on the tumour type, its overexpression is either associated with improved or worse patient survival. For ovarian cancer, however, the role of EpCAM remains unclear. Methods: Cell survival of ovarian cancer cell lines was studied after induction or repression of endogenous EpCAM expression using siRNA/cDNA or artificial transcription factors (ATF) consisting of engineered zinc-fingers fused to either a transcriptional activator or repressor domain. Results: Two ATFs were selected as the most potent down- and upregulator, showing at least a two-fold alteration of EpCAM protein expression compared with control. Downregulation of EpCAM expression resulted in growth inhibition in breast cancer, but showed no effect on cell growth in ovarian cancer. Induction or further upregulation of EpCAM expression decreased ovarian cancer cell survival. Conclusion: The bidirectional ATF-based approach is uniquely suited to study cell-type-specific biological effects of EpCAM expression. Using this approach, the oncogenic function of EpCAM in breast cancer was confirmed. Despite its value as a diagnostic marker and for immunotherapy, EpCAM does not seem to represent a therapeutic target for gene expression silencing in ovarian cancer. PMID:23403823

  3. Collecting Information About a CAM Practitioner’s Practice: A Preliminary Report of a Self-Interview Methodology

    PubMed Central

    Elder, William G.; Purdy, Hunter; Bentley, Andrew

    2009-01-01

    To prepare allopathic providers to advise patients about complementary and alternative medicine (CAM) therapies, the University of Kentucky CAM curriculum integration project has identified and trained CAM practitioners to coteach, precept, and demonstrate their respective practices. This project is interested in integrating CAM practitioners as teachers into this university and has formed a multidisciplinary committee for advice. The committee has recognized the importance of increased understanding of CAM practices to enhance communication within itself and to decide to which CAM practices students should receive exposure. This article reports our attempt to create a CAM practice description, based on questions general to CAM practice and specific to a particular approach. Because there is limited existing systematic research on CAM practice characteristics, these questions may interest researchers conducting qualitative studies, especially those seeking an example of questions to ask CAM practitioners. We also believe this practice description will be of general interest. PMID:19890441

  4. Expression of L1-CAM and ADAM10 in human colon cancer cells induces metastasis.

    PubMed

    Gavert, Nancy; Sheffer, Michal; Raveh, Shani; Spaderna, Simone; Shtutman, Michael; Brabletz, Thomas; Barany, Francis; Paty, Phillip; Notterman, Daniel; Domany, Eytan; Ben-Ze'ev, Avri

    2007-08-15

    L1-CAM, a neuronal cell adhesion receptor, is also expressed in a variety of cancer cells. Recent studies identified L1-CAM as a target gene of beta-catenin-T-cell factor (TCF) signaling expressed at the invasive front of human colon cancer tissue. We found that L1-CAM expression in colon cancer cells lacking L1-CAM confers metastatic capacity, and mice injected in their spleen with such cells form liver metastases. We identified ADAM10, a metalloproteinase that cleaves the L1-CAM extracellular domain, as a novel target gene of beta-catenin-TCF signaling. ADAM10 overexpression in colon cancer cells displaying endogenous L1-CAM enhanced L1-CAM cleavage and induced liver metastasis, and ADAM10 also enhanced metastasis in colon cancer cells stably transfected with L1-CAM. DNA microarray analysis of genes induced by L1-CAM in colon cancer cells identified a cluster of genes also elevated in a large set of human colon carcinoma tissue samples. Expression of these genes in normal colon epithelium was low. These results indicate that there is a gene program induced by L1-CAM in colon cancer cells that is also present in colorectal cancer tissue and suggest that L1-CAM can serve as target for colon cancer therapy.

  5. Camera calibration: active versus passive targets

    NASA Astrophysics Data System (ADS)

    Schmalz, Christoph; Forster, Frank; Angelopoulou, Elli

    2011-11-01

    Traditionally, most camera calibrations rely on a planar target with well-known marks. However, the localization error of the marks in the image is a source of inaccuracy. We propose the use of high-resolution digital displays as active calibration targets to obtain more accurate calibration results for all types of cameras. The display shows a series of coded patterns to generate correspondences between world points and image points. This has several advantages. No special calibration hardware is necessary because suitable displays are practically ubiquitious. The method is fully automatic, and no identification of marks is necessary. For a coding scheme based on phase shifting, the localization accuracy is approximately independent of the camera's focus settings. Most importantly, higher accuracy can be achieved compared to passive targets, such as printed checkerboards. A rigorous evaluation is performed to substantiate this claim. Our active target method is compared to standard calibrations using a checkerboard target. We perform camera, calibrations with different combinations of displays, cameras, and lenses, as well as with simulated images and find markedly lower reprojection errors when using active targets. For example, in a stereo reconstruction task, the accuracy of a system calibrated with an active target is five times better.

  6. Arabidopsis CaM1 and CaM4 Promote Nitric Oxide Production and Salt Resistance by Inhibiting S-Nitrosoglutathione Reductase via Direct Binding

    PubMed Central

    Wu, Dan; Peng, Xuan; Liu, Xu; Zhang, Jiaojiao; Zhao, Junfeng; Chen, Kunming; Zhao, Liqun

    2016-01-01

    Salt is a major threat to plant growth and crop productivity. Calmodulin (CaM), the most important multifunctional Ca2+ sensor protein in plants, mediates reactions against environmental stresses through target proteins; however, direct proof of the participation of CaM in salt tolerance and its corresponding signaling pathway in vivo is lacking. In this study, we found that AtCaM1 and AtCaM4 produced salt-responsive CaM isoforms according to real-time reverse transcription-polymerase chain reaction analyses; this result was verified based on a phenotypic analysis of salt-treated loss-of-function mutant and transgenic plants. We also found that the level of nitric oxide (NO), an important salt-responsive signaling molecule, varied in response to salt treatment depending on AtCaM1 and AtCaM4 expression. GSNOR is considered as an important and widely utilized regulatory component of NO homeostasis in plant resistance protein signaling networks. In vivo and in vitro protein-protein interaction assays revealed direct binding between AtCaM4 and S-nitrosoglutathione reductase (GSNOR), leading to reduced GSNOR activity and an increased NO level. Overexpression of GSNOR intensified the salt sensitivity of cam4 mutant plants accompanied by a reduced internal NO level, whereas a gsnor deficiency increased the salt tolerance of cam4 plants accompanied by an increased internal NO level. Physiological experiments showed that CaM4-GSNOR, acting through NO, reestablished the ion balance to increase plant resistance to salt stress. Together, these data suggest that AtCaM1 and AtCaM4 serve as signals in plant salt resistance by promoting NO accumulation through the binding and inhibition of GSNOR. This could be a conserved defensive signaling pathway in plants and animals. PMID:27684709

  7. Head-coupled remote stereoscopic camera system for telepresence applications

    NASA Astrophysics Data System (ADS)

    Bolas, Mark T.; Fisher, Scott S.

    1990-09-01

    The Virtual Environment Workstation Project (VIEW) at NASA's Ames Research Center has developed a remotely controlled stereoscopic camera system that can be used for telepresence research and as a tool to develop and evaluate configurations for head-coupled visual systems associated with space station telerobots and remote manipulation robotic arms. The prototype camera system consists of two lightweight CCD video cameras mounted on a computer controlled platform that provides real-time pan, tilt, and roll control of the camera system in coordination with head position transmitted from the user. This paper provides an overall system description focused on the design and implementation of the camera and platform hardware configuration and the development of control software. Results of preliminary performance evaluations are reported with emphasis on engineering and mechanical design issues and discussion of related psychophysiological effects and objectives.

  8. An electrically tunable plenoptic camera using a liquid crystal microlens array

    NASA Astrophysics Data System (ADS)

    Lei, Yu; Tong, Qing; Zhang, Xinyu; Sang, Hongshi; Ji, An; Xie, Changsheng

    2015-05-01

    Plenoptic cameras generally employ a microlens array positioned between the main lens and the image sensor to capture the three-dimensional target radiation in the visible range. Because the focal length of common refractive or diffractive microlenses is fixed, the depth of field (DOF) is limited so as to restrict their imaging capability. In this paper, we propose a new plenoptic camera using a liquid crystal microlens array (LCMLA) with electrically tunable focal length. The developed LCMLA is fabricated by traditional photolithography and standard microelectronic techniques, and then, its focusing performance is experimentally presented. The fabricated LCMLA is directly integrated with an image sensor to construct a prototyped LCMLA-based plenoptic camera for acquiring raw radiation of targets. Our experiments demonstrate that the focused region of the LCMLA-based plenoptic camera can be shifted efficiently through electrically tuning the LCMLA used, which is equivalent to the extension of the DOF.

  9. An electrically tunable plenoptic camera using a liquid crystal microlens array.

    PubMed

    Lei, Yu; Tong, Qing; Zhang, Xinyu; Sang, Hongshi; Ji, An; Xie, Changsheng

    2015-05-01

    Plenoptic cameras generally employ a microlens array positioned between the main lens and the image sensor to capture the three-dimensional target radiation in the visible range. Because the focal length of common refractive or diffractive microlenses is fixed, the depth of field (DOF) is limited so as to restrict their imaging capability. In this paper, we propose a new plenoptic camera using a liquid crystal microlens array (LCMLA) with electrically tunable focal length. The developed LCMLA is fabricated by traditional photolithography and standard microelectronic techniques, and then, its focusing performance is experimentally presented. The fabricated LCMLA is directly integrated with an image sensor to construct a prototyped LCMLA-based plenoptic camera for acquiring raw radiation of targets. Our experiments demonstrate that the focused region of the LCMLA-based plenoptic camera can be shifted efficiently through electrically tuning the LCMLA used, which is equivalent to the extension of the DOF.

  10. Is complementary and alternative medicine (CAM) cost-effective? a systematic review

    PubMed Central

    Herman, Patricia M; Craig, Benjamin M; Caspi, Opher

    2005-01-01

    Background Out-of-pocket expenditures of over $34 billion per year in the US are an apparent testament to a widely held belief that complementary and alternative medicine (CAM) therapies have benefits that outweigh their costs. However, regardless of public opinion, there is often little more than anecdotal evidence on the health and economic implications of CAM therapies. The objectives of this study are to present an overview of economic evaluation and to expand upon a previous review to examine the current scope and quality of CAM economic evaluations. Methods The data sources used were Medline, AMED, Alt-HealthWatch, and the Complementary and Alternative Medicine Citation Index; January 1999 to October 2004. Papers that reported original data on specific CAM therapies from any form of standard economic analysis were included. Full economic evaluations were subjected to two types of quality review. The first was a 35-item checklist for reporting quality, and the second was a set of four criteria for study quality (randomization, prospective collection of economic data, comparison to usual care, and no blinding). Results A total of 56 economic evaluations (39 full evaluations) of CAM were found covering a range of therapies applied to a variety of conditions. The reporting quality of the full evaluations was poor for certain items, but was comparable to the quality found by systematic reviews of economic evaluations in conventional medicine. Regarding study quality, 14 (36%) studies were found to meet all four criteria. These exemplary studies indicate CAM therapies that may be considered cost-effective compared to usual care for various conditions: acupuncture for migraine, manual therapy for neck pain, spa therapy for Parkinson's, self-administered stress management for cancer patients undergoing chemotherapy, pre- and post-operative oral nutritional supplementation for lower gastrointestinal tract surgery, biofeedback for patients with "functional" disorders

  11. In Vitro Analysis of the Fracture Resistance of CAD/CAM Denture Base Resins.

    PubMed

    Steinmassl, Otto; Offermanns, Vincent; Stöckl, Wolfgang; Dumfahrt, Herbert; Grunert, Ingrid; Steinmassl, Patricia-Anca

    2018-03-08

    Computer-aided design and computer-aided manufacturing (CAD/CAM) denture base manufacturers claim to produce their resin pucks under high heat and pressure. Therefore, CAD/CAM dentures are assumed to have enhanced mechanical properties and, as a result, are often produced with lower denture base thicknesses than conventional, manually fabricated dentures. The aim of this study was to investigate if commercially available CAD/CAM denture base resins have more favourable mechanical properties than conventionally processed denture base resins. For this purpose, a series of three-point bending tests conforming to ISO specifications were performed on a total of 80 standardised, rectangular CAD/CAM denture base resin specimens from five different manufacturers (AvaDent, Baltic Denture System, Vita VIONIC, Whole You Nexteeth, and Wieland Digital Dentures). A heat-polymerising resin and an autopolymerising resin served as the control groups. The breaking load, fracture toughness, and the elastic modulus were assessed. Additionally, the fracture surface roughness and texture were investigated. Only one CAD/CAM resin showed a significantly increased breaking load. Two CAD/CAM resins had a significantly higher fracture toughness than the control groups, and all CAD/CAM resins had higher elastic moduli than the controls. Our results indicate that CAD/CAM denture base resins do not generally have better mechanical properties than manually processed resins. Therefore, the lower minimum denture base thicknesses should be regarded with some caution.

  12. In Vitro Analysis of the Fracture Resistance of CAD/CAM Denture Base Resins

    PubMed Central

    Stöckl, Wolfgang; Dumfahrt, Herbert; Grunert, Ingrid

    2018-01-01

    Computer-aided design and computer-aided manufacturing (CAD/CAM) denture base manufacturers claim to produce their resin pucks under high heat and pressure. Therefore, CAD/CAM dentures are assumed to have enhanced mechanical properties and, as a result, are often produced with lower denture base thicknesses than conventional, manually fabricated dentures. The aim of this study was to investigate if commercially available CAD/CAM denture base resins have more favourable mechanical properties than conventionally processed denture base resins. For this purpose, a series of three-point bending tests conforming to ISO specifications were performed on a total of 80 standardised, rectangular CAD/CAM denture base resin specimens from five different manufacturers (AvaDent, Baltic Denture System, Vita VIONIC, Whole You Nexteeth, and Wieland Digital Dentures). A heat-polymerising resin and an autopolymerising resin served as the control groups. The breaking load, fracture toughness, and the elastic modulus were assessed. Additionally, the fracture surface roughness and texture were investigated. Only one CAD/CAM resin showed a significantly increased breaking load. Two CAD/CAM resins had a significantly higher fracture toughness than the control groups, and all CAD/CAM resins had higher elastic moduli than the controls. Our results indicate that CAD/CAM denture base resins do not generally have better mechanical properties than manually processed resins. Therefore, the lower minimum denture base thicknesses should be regarded with some caution. PMID:29518022

  13. Students' framing of laboratory exercises using infrared cameras

    NASA Astrophysics Data System (ADS)

    Haglund, Jesper; Jeppsson, Fredrik; Hedberg, David; Schönborn, Konrad J.

    2015-12-01

    Thermal science is challenging for students due to its largely imperceptible nature. Handheld infrared cameras offer a pedagogical opportunity for students to see otherwise invisible thermal phenomena. In the present study, a class of upper secondary technology students (N =30 ) partook in four IR-camera laboratory activities, designed around the predict-observe-explain approach of White and Gunstone. The activities involved central thermal concepts that focused on heat conduction and dissipative processes such as friction and collisions. Students' interactions within each activity were videotaped and the analysis focuses on how a purposefully selected group of three students engaged with the exercises. As the basis for an interpretative study, a "thick" narrative description of the students' epistemological and conceptual framing of the exercises and how they took advantage of the disciplinary affordance of IR cameras in the thermal domain is provided. Findings include that the students largely shared their conceptual framing of the four activities, but differed among themselves in their epistemological framing, for instance, in how far they found it relevant to digress from the laboratory instructions when inquiring into thermal phenomena. In conclusion, the study unveils the disciplinary affordances of infrared cameras, in the sense of their use in providing access to knowledge about macroscopic thermal science.

  14. Comparison of denture tooth movement between CAD-CAM and conventional fabrication techniques.

    PubMed

    Goodacre, Brian J; Goodacre, Charles J; Baba, Nadim Z; Kattadiyil, Mathew T

    2018-01-01

    Data comparing the denture tooth movement of computer-aided design and computer-aided manufacturing (CAD-CAM) and conventional denture processing techniques are lacking. The purpose of this in vitro study was to compare the denture tooth movement of pack-and-press, fluid resin, injection, CAD-CAM-bonded, and CAD-CAM monolithic techniques for fabricating dentures to determine which process produces the most accurate and reproducible prosthesis. A total of 50 dentures were evaluated, 10 for each of the 5 groups. A master denture was fabricated and milled from prepolymerized poly(methyl methacrylate). For the conventional processing techniques (pack-and-press, fluid resin, and injection) a polyvinyl siloxane putty mold of the master denture was made in which denture teeth were placed and molten wax injected. The cameo surface of each wax-festooned denture was laser scanned, resulting in a standard tessellation language (STL) format file. The CAD-CAM dentures included 2 subgroups: CAD-CAM-bonded teeth in which the denture teeth were bonded into the milled denture base and CAD-CAM monolithic teeth in which the denture teeth were milled as part of the denture base. After all specimens had been fabricated, they were hydrated for 24 hours, and the cameo surface laser scanned. The preprocessing and postprocessing scan files of each denture were superimposed using surface-matching software. Measurements were made at 64 locations, allowing evaluation of denture tooth movement in a buccal, lingual, mesial-distal, and occlusal direction. The use of median and interquartile range values was used to assess accuracy and reproducibility. Levene and Kruskal-Wallis analyses of variance were used to evaluate differences between processing techniques (α=.05). The CAD-CAM monolithic technique was the most accurate, followed by fluid resin, CAD-CAM-bonded, pack-and-press, and injection. CAD-CAM monolithic technique was the most reproducible, followed by pack-and-press, CAD-CAM

  15. Medical student attitudes towards complementary and alternative medicine (CAM) in medical education: a critical review.

    PubMed

    Joyce, Paul; Wardle, Jon; Zaslawski, Chris

    2016-12-01

    Background This paper aims to remedy a gap in the knowledge by presenting the first critical review of the literature on major themes relating to medical students perceptions and attitudes towards the exponentially growing field of complementary and alternative medicine (CAM). MethodsAfter a comprehensive database search of the literature, 21 papers were chosen as suitable for the review. The results from these papers were tabled and discussed. ResultsThe results indicated that medical students lacked knowledge of CAM and are generally positive towards CAM education (especially in the preclinical years, if it provided evidence of efficacy and post-placement). Medical students thought that CAM should generally be incorporated into the medical curriculum mainly so they can confidently undertake referral to CAM practitioners. Being able to communicate with future patients about their CAM use was a major motivation for medical students to learn about CAM and a factor for medical student support of further incorporation of CAM content in the medical curricula. Educational exposure to CAM in many forms and in many papers was shown to significantly affect medical student attitudes to CAM. This may be reflective of the fact that, outside direct CAM training, there may be limited accessible opportunities for medical students and if integration is to occur, educational exposure is most important. ConclusionsThe rise of CAM as a social and clinical phenomenon necessitates consideration of further inclusion of these topics in the medical curriculum, if future physicians are to be able to fully discharge their role as care providers in an increasingly medically pluralistic world. However, the inclusion of CAM needs to be done in an objective and critical manner, which is relevant to the learner.

  16. The sL1CAM in sera of patients with endometrial and ovarian cancers.

    PubMed

    Wojciechowski, Michał; Głowacka, Ewa; Wilczyński, Miłosz; Pękala-Wojciechowska, Anna; Malinowski, Andrzej

    2017-01-01

    L1CAM is a cell adhesion molecule suspected to play an important role in carcinogenesis. The objective of the study was to evaluate the level of soluble L1CAM in the sera of patients with endometrial and ovarian carcinomas and verify the feasibility of the sL1CAM as a marker of these carcinomas. 35 endometrial and 18 ovarian cancer patients were enrolled in the study. 43 patients with benign gynecological conditions constituted a control group. The sL1CAM serum level was measured with ELISA test in each patient and it was referred to the data from the surgical staging of the cancers. The sL1CAM serum level was significantly lower in patients with endometrial cancer than in healthy women and slightly lower in the ovarian cancer group than in the control group. In the endometrial cancer group there was no correlation between sL1CAM concentration and cancer histopathology, stage or grade. sL1CAM concentration positively correlated with ovarian cancer stage and (not significantly) with grade. Despite the increasing data about the possible role of L1CAM as a strong prognostic factor of poor outcome in many cancers, we did not find evidence supporting the use of sL1CAM as a marker of endometrial or ovarian cancers.

  17. Marginal adaptation and CAD-CAM technology: A systematic review of restorative material and fabrication techniques.

    PubMed

    Papadiochou, Sofia; Pissiotis, Argirios L

    2018-04-01

    The comparative assessment of computer-aided design and computer-aided manufacturing (CAD-CAM) technology and other fabrication techniques pertaining to marginal adaptation should be documented. Limited evidence exists on the effect of restorative material on the performance of a CAD-CAM system relative to marginal adaptation. The purpose of this systematic review was to investigate whether the marginal adaptation of CAD-CAM single crowns, fixed dental prostheses, and implant-retained fixed dental prostheses or their infrastructures differs from that obtained by other fabrication techniques using a similar restorative material and whether it depends on the type of restorative material. An electronic search of English-language literature published between January 1, 2000, and June 30, 2016, was conducted of the Medline/PubMed database. Of the 55 included comparative studies, 28 compared CAD-CAM technology with conventional fabrication techniques, 12 contrasted CAD-CAM technology and copy milling, 4 compared CAD-CAM milling with direct metal laser sintering (DMLS), and 22 investigated the performance of a CAD-CAM system regarding marginal adaptation in restorations/infrastructures produced with different restorative materials. Most of the CAD-CAM restorations/infrastructures were within the clinically acceptable marginal discrepancy (MD) range. The performance of a CAD-CAM system relative to marginal adaptation is influenced by the restorative material. Compared with CAD-CAM, most of the heat-pressed lithium disilicate crowns displayed equal or smaller MD values. Slip-casting crowns exhibited similar or better marginal accuracy than those fabricated with CAD-CAM. Cobalt-chromium and titanium implant infrastructures produced using a CAD-CAM system elicited smaller MD values than zirconia. The majority of cobalt-chromium restorations/infrastructures produced by DMLS displayed better marginal accuracy than those fabricated with the casting technique. Compared with copy

  18. Gas exchange and leaf anatomy of a C3-CAM hybrid, Yucca gloriosa (Asparagaceae).

    PubMed

    Heyduk, Karolina; Burrell, Nia; Lalani, Falak; Leebens-Mack, Jim

    2016-03-01

    While the majority of plants use the typical C3 carbon metabolic pathway, ~6% of angiosperms have adapted to carbon limitation as a result of water stress by employing a modified form of photosynthesis known as Crassulacean acid metabolism (CAM). CAM plants concentrate carbon in the cells by temporally separating atmospheric carbon acquisition from fixation into carbohydrates. CAM has been studied for decades, but the evolutionary progression from C3 to CAM remains obscure. In order to better understand the morphological and physiological characteristics associated with CAM photosynthesis, phenotypic variation was assessed in Yucca aloifolia, a CAM species, Yucca filamentosa, a C3 species, and Yucca gloriosa, a hybrid species derived from these two yuccas exhibiting intermediate C3-CAM characteristics. Gas exchange, titratable leaf acidity, and leaf anatomical traits of all three species were assayed in a common garden under well-watered and drought-stressed conditions. Yucca gloriosa showed intermediate phenotypes for nearly all traits measured, including the ability to acquire carbon at night. Using the variation found among individuals of all three species, correlations between traits were assessed to better understand how leaf anatomy and CAM physiology are related. Yucca gloriosa may be constrained by a number of traits which prevent it from using CAM to as high a degree as Y. aloifolia. The intermediate nature of Y. gloriosa makes it a promising system in which to study the evolution of CAM. © The Author 2015. Published by Oxford University Press on behalf of the Society for Experimental Biology.

  19. CO2 Acquisition Membrane (CAM) Project

    NASA Technical Reports Server (NTRS)

    Mason, Larry W.

    2003-01-01

    The CO2 Acquisition Membrane (CAM) project was performed to develop, test, and analyze thin film membrane materials for separation and purification of carbon dioxide (CO2) from mixtures of gases, such as those found in the Martian atmosphere. The membranes developed in this project are targeted toward In Situ Resource Utilization (ISRU) applications, such as In Situ Propellant Production (ISPP) and In Situ Consumables Production (ISCP). These membrane materials may be used in a variety of ISRU systems, for example as the atmospheric inlet filter for an ISPP process to enhance the concentration of CO2 for use as a reactant gas, to passively separate argon and nitrogen trace gases from CO2 for habitat pressurization, to provide a system for removal of CO2 from breathing gases in a closed environment, or within a process stream to selectively separate CO2 from other gaseous components. The membranes identified and developed for CAM were evaluated for use in candidate ISRU processes and other gas separation applications, and will help to lay the foundation for future unmanned sample return and human space missions. CAM is a cooperative project split among three institutions: Lockheed Martin Astronautics (LMA), the Colorado School of Mines (CSM), and Marshall Space Flight Center (MSFC).

  20. Perspectives of complementary and alternative medicine (CAM) practitioners in the support and treatment of infertility.

    PubMed

    O'Reilly, Erin; Sevigny, Marika; Sabarre, Kelley-Anne; Phillips, Karen P

    2014-10-14

    Infertility patients are increasingly using complementary and alternative medicine (CAM) to supplement or replace conventional fertility treatments. The objective of this study was to determine the roles of CAM practitioners in the support and treatment of infertility. Ten semi-structured interviews were conducted in Ottawa, Canada in 2011 with CAM practitioners who specialized in naturopathy, acupuncture, traditional Chinese medicine, hypnotherapy and integrated medicine. CAM practitioners played an active role in both treatment and support of infertility, using a holistic, interdisciplinary and individualized approach. CAM practitioners recognized biological but also environmental and psychosomatic determinants of infertility. Participants were receptive to working with physicians, however little collaboration was described. Integrated infertility patient care through both collaboration with CAM practitioners and incorporation of CAM's holistic, individualized and interdisciplinary approaches would greatly benefit infertility patients.

  1. The star formation history of the Sextans dwarf spheroidal galaxy: a true fossil of the pre-reionization era

    NASA Astrophysics Data System (ADS)

    Bettinelli, M.; Hidalgo, S. L.; Cassisi, S.; Aparicio, A.; Piotto, G.

    2018-05-01

    We present the star formation history (SFH) of the Sextans dwarf spheroidal galaxy based on deep archive B, I photometry taken with Suprime-Cam at Subaru telescope focusing our analysis on the inner region of the galaxy, fully located within the core radius. Within the errors of our SFH, we have not detected any metallicity gradient along the considered radial distance interval. As a main result of this work, we can state that the Sextans dwarf spheroidal stopped forming stars less than ˜1.3 Gyr after big bang in correspondence to the end of the reionization epoch. We have been able to constrain the duration of the main burst of star formation to ˜0.6 Gyr. From the calculation of the mechanical luminosity released from supernovae (SNe) during the brief episode of star formation, there are strong indications that SNe could have played an important role in the fate of Sextans, by removing almost completely the gas component, so preventing a prolonged star formation.

  2. Analysis of Mass Averaged Tissue Doses in CAM, CAF, MAX, and FAX

    NASA Technical Reports Server (NTRS)

    Slaba, Tony C.; Qualls, Garry D.; Clowdsley, Martha S.; Blattnig, Steve R.; Simonsen, Lisa C.; Walker, Steven A.; Singleterry, Robert C.

    2009-01-01

    To estimate astronaut health risk due to space radiation, one must have the ability to calculate exposure-related quantities averaged over specific organs and tissue types. In this study, we first examine the anatomical properties of the Computerized Anatomical Man (CAM), Computerized Anatomical Female (CAF), Male Adult voXel (MAX), and Female Adult voXel (FAX) models by comparing the masses of various tissues to the reference values specified by the International Commission on Radiological Protection (ICRP). Major discrepancies are found between the CAM and CAF tissue masses and the ICRP reference data for almost all of the tissues. We next examine the distribution of target points used with the deterministic transport code HZETRN to compute mass averaged exposure quantities. A numerical algorithm is used to generate multiple point distributions for many of the effective dose tissues identified in CAM, CAF, MAX, and FAX. It is concluded that the previously published CAM and CAF point distributions were under-sampled and that the set of point distributions presented here should be adequate for future studies involving CAM, CAF, MAX, or FAX. It is concluded that MAX and FAX are more accurate than CAM and CAF for space radiation analyses.

  3. The CUPCIG (CAM-Use in Primary Care in Germany) Study:Part I-Pain. Study Protocol of a Pilot-trial to Assess Feasibility, Acceptability and Perceived Effectiveness of CAM in Pain Disorders in Primary Care.

    PubMed

    Schencking, Martin; Sönnichsen, Andreas; Bassüner, Susanne; Redaelli, Marcus

    2015-01-01

    There is limited valid data available on CAM procedures for chronic joint and neuropathic pain in primary care in Germany. Indiviual CAM qualifications of the general practitioners (GPs) and the potential of cost reduction through CAM treatment are almost unknown. The aim of this pilot trial preceding the main study is to examine the survey mode, to estimate the response rate by GPs with or without an additional qualification for CAM, and to identify the status quo in therapeutic approaches for chronic pain disorders in primary care. This is a cross-sectional study with an ex post facto design among German GPs consisting of 2 parts: In a first step, a pilot trial precedes the main study targeting 200 GPs with and 200 GPs without additional qualification in CAM in a selected region. The results of the CUPCIG study comprise the distribution of pain types treated in primary care practices, the GPs' attitude toward complementary pain therapy, pharmacological or CAM treatment, the estimate of cost reduction through CAM treatment of pain, the application of diverse CAM procedures, and biographical data. The CUPCIG study serves to compile pain therapy approaches in primary care in Germany with respect to the individual CAM expertise of the GPs. © 2015 S. Karger GmbH, Freiburg.

  4. Opto-mechanical design of the G-CLEF flexure control camera system

    NASA Astrophysics Data System (ADS)

    Oh, Jae Sok; Park, Chan; Kim, Jihun; Kim, Kang-Min; Chun, Moo-Young; Yu, Young Sam; Lee, Sungho; Nah, Jakyoung; Park, Sung-Joon; Szentgyorgyi, Andrew; McMuldroch, Stuart; Norton, Timothy; Podgorski, William; Evans, Ian; Mueller, Mark; Uomoto, Alan; Crane, Jeffrey; Hare, Tyson

    2016-08-01

    The GMT-Consortium Large Earth Finder (G-CLEF) is the very first light instrument of the Giant Magellan Telescope (GMT). The G-CLEF is a fiber feed, optical band echelle spectrograph that is capable of extremely precise radial velocity measurement. KASI (Korea Astronomy and Space Science Institute) is responsible for Flexure Control Camera (FCC) included in the G-CLEF Front End Assembly (GCFEA). The FCC is a kind of guide camera, which monitors the field images focused on a fiber mirror to control the flexure and the focus errors within the GCFEA. The FCC consists of five optical components: a collimator including triple lenses for producing a pupil, neutral density filters allowing us to use much brighter star as a target or a guide, a tent prism as a focus analyzer for measuring the focus offset at the fiber mirror, a reimaging camera with three pair of lenses for focusing the beam on a CCD focal plane, and a CCD detector for capturing the image on the fiber mirror. In this article, we present the optical and mechanical FCC designs which have been modified after the PDR in April 2015.

  5. Advancement of thyroid surgery video recording: A comparison between two full HD head mounted video cameras.

    PubMed

    Ortensi, Andrea; Panunzi, Andrea; Trombetta, Silvia; Cattaneo, Alberto; Sorrenti, Salvatore; D'Orazi, Valerio

    2017-05-01

    The aim of this study was to test two different video cameras and recording systems used in thyroid surgery in our Department. This is meant to be an attempt to record the real point of view of the magnified vision of surgeon, so as to make the viewer aware of the difference with the naked eye vision. In this retrospective study, we recorded and compared twenty thyroidectomies performed using loupes magnification and microsurgical technique: ten were recorded with GoPro ® 4 Session action cam (commercially available) and ten with our new prototype of head mounted video camera. Settings were selected before surgery for both cameras. The recording time is about from 1 to 2 h for GoPro ® and from 3 to 5 h for our prototype. The average time of preparation to fit the camera on the surgeon's head and set the functionality is about 5 min for GoPro ® and 7-8 min for the prototype, mostly due to HDMI wiring cable. Videos recorded with the prototype require no further editing, which is mandatory for videos recorded with GoPro ® to highlight the surgical details. the present study showed that our prototype of video camera, compared with GoPro ® 4 Session, guarantees best results in terms of surgical video recording quality, provides to the viewer the exact perspective of the microsurgeon and shows accurately his magnified view through the loupes in thyroid surgery. These recordings are surgical aids for teaching and education and might be a method of self-analysis of surgical technique. Copyright © 2017 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  6. Child/Adolescent Anxiety Multimodal Study (CAMS): rationale, design, and methods

    PubMed Central

    2010-01-01

    Objective To present the design, methods, and rationale of the Child/Adolescent Anxiety Multimodal Study (CAMS), a recently completed federally-funded, multi-site, randomized placebo-controlled trial that examined the relative efficacy of cognitive-behavior therapy (CBT), sertraline (SRT), and their combination (COMB) against pill placebo (PBO) for the treatment of separation anxiety disorder (SAD), generalized anxiety disorder (GAD) and social phobia (SoP) in children and adolescents. Methods Following a brief review of the acute outcomes of the CAMS trial, as well as the psychosocial and pharmacologic treatment literature for pediatric anxiety disorders, the design and methods of the CAMS trial are described. Results CAMS was a six-year, six-site, randomized controlled trial. Four hundred eighty-eight (N = 488) children and adolescents (ages 7-17 years) with DSM-IV-TR diagnoses of SAD, GAD, or SoP were randomly assigned to one of four treatment conditions: CBT, SRT, COMB, or PBO. Assessments of anxiety symptoms, safety, and functional outcomes, as well as putative mediators and moderators of treatment response were completed in a multi-measure, multi-informant fashion. Manual-based therapies, trained clinicians and independent evaluators were used to ensure treatment and assessment fidelity. A multi-layered administrative structure with representation from all sites facilitated cross-site coordination of the entire trial, study protocols and quality assurance. Conclusions CAMS offers a model for clinical trials methods applicable to psychosocial and psychopharmacological comparative treatment trials by using state-of-the-art methods and rigorous cross-site quality controls. CAMS also provided a large-scale examination of the relative and combined efficacy and safety of the best evidenced-based psychosocial (CBT) and pharmacologic (SSRI) treatments to date for the most commonly occurring pediatric anxiety disorders. Primary and secondary results of CAMS will hold

  7. PCI bus content-addressable-memory (CAM) implementation on FPGA for pattern recognition/image retrieval in a distributed environment

    NASA Astrophysics Data System (ADS)

    Megherbi, Dalila B.; Yan, Yin; Tanmay, Parikh; Khoury, Jed; Woods, C. L.

    2004-11-01

    Recently surveillance and Automatic Target Recognition (ATR) applications are increasing as the cost of computing power needed to process the massive amount of information continues to fall. This computing power has been made possible partly by the latest advances in FPGAs and SOPCs. In particular, to design and implement state-of-the-Art electro-optical imaging systems to provide advanced surveillance capabilities, there is a need to integrate several technologies (e.g. telescope, precise optics, cameras, image/compute vision algorithms, which can be geographically distributed or sharing distributed resources) into a programmable system and DSP systems. Additionally, pattern recognition techniques and fast information retrieval, are often important components of intelligent systems. The aim of this work is using embedded FPGA as a fast, configurable and synthesizable search engine in fast image pattern recognition/retrieval in a distributed hardware/software co-design environment. In particular, we propose and show a low cost Content Addressable Memory (CAM)-based distributed embedded FPGA hardware architecture solution with real time recognition capabilities and computing for pattern look-up, pattern recognition, and image retrieval. We show how the distributed CAM-based architecture offers a performance advantage of an order-of-magnitude over RAM-based architecture (Random Access Memory) search for implementing high speed pattern recognition for image retrieval. The methods of designing, implementing, and analyzing the proposed CAM based embedded architecture are described here. Other SOPC solutions/design issues are covered. Finally, experimental results, hardware verification, and performance evaluations using both the Xilinx Virtex-II and the Altera Apex20k are provided to show the potential and power of the proposed method for low cost reconfigurable fast image pattern recognition/retrieval at the hardware/software co-design level.

  8. 7. VAL CAMERA CAR, DETAIL OF 'FLARE' OR TRAJECTORY CAMERA ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. VAL CAMERA CAR, DETAIL OF 'FLARE' OR TRAJECTORY CAMERA INSIDE CAMERA CAR. - Variable Angle Launcher Complex, Camera Car & Track, CA State Highway 39 at Morris Reservior, Azusa, Los Angeles County, CA

  9. Multi-Target Camera Tracking, Hand-off and Display LDRD 158819 Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anderson, Robert J.

    2014-10-01

    Modern security control rooms gather video and sensor feeds from tens to hundreds of cameras. Advanced camera analytics can detect motion from individual video streams and convert unexpected motion into alarms, but the interpretation of these alarms depends heavily upon human operators. Unfortunately, these operators can be overwhelmed when a large number of events happen simultaneously, or lulled into complacency due to frequent false alarms. This LDRD project has focused on improving video surveillance-based security systems by changing the fundamental focus from the cameras to the targets being tracked. If properly integrated, more cameras shouldn’t lead to more alarms, moremore » monitors, more operators, and increased response latency but instead should lead to better information and more rapid response times. For the course of the LDRD we have been developing algorithms that take live video imagery from multiple video cameras, identify individual moving targets from the background imagery, and then display the results in a single 3D interactive video. In this document we summarize the work in developing this multi-camera, multi-target system, including lessons learned, tools developed, technologies explored, and a description of current capability.« less

  10. Multi-target camera tracking, hand-off and display LDRD 158819 final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anderson, Robert J.

    2014-10-01

    Modern security control rooms gather video and sensor feeds from tens to hundreds of cameras. Advanced camera analytics can detect motion from individual video streams and convert unexpected motion into alarms, but the interpretation of these alarms depends heavily upon human operators. Unfortunately, these operators can be overwhelmed when a large number of events happen simultaneously, or lulled into complacency due to frequent false alarms. This LDRD project has focused on improving video surveillance-based security systems by changing the fundamental focus from the cameras to the targets being tracked. If properly integrated, more cameras shouldn't lead to more alarms, moremore » monitors, more operators, and increased response latency but instead should lead to better information and more rapid response times. For the course of the LDRD we have been developing algorithms that take live video imagery from multiple video cameras, identifies individual moving targets from the background imagery, and then displays the results in a single 3D interactive video. In this document we summarize the work in developing this multi-camera, multi-target system, including lessons learned, tools developed, technologies explored, and a description of current capability.« less

  11. Day/night regulation of aquaporins during the CAM cycle in Mesembryanthemum crystallinum.

    PubMed

    Vera-Estrella, Rosario; Barkla, Bronwyn J; Amezcua-Romero, Julio C; Pantoja, Omar

    2012-03-01

    Mesembryanthemum crystallinum exhibits induction of Crassulacean acid metabolism (CAM) after a threshold stage of development, by exposure to long days with high light intensities or by water and salt stress. During the CAM cycle, fluctuations in carbon partitioning within the cell lead to transient drops in osmotic potential, which are likely stabilized/balanced by passive movement of water via aquaporins (AQPs). Protoplast swelling assays were used to detect changes in water permeability during the day/night cycle of CAM. To assess the role of AQPs during the same period, we followed transcript accumulation and protein abundance of four plasma membrane intrinsic proteins (PIPs) and one tonoplast intrinsic protein (TIP). CAM plants showed a persistent rhythm of specific AQP protein abundance changes throughout the day/night cycle, including changes in amount of McPIP2;1, McTIP1;2, McPIP1;4 and McPIP1;5, while the abundance of McPIP1;2 was unchanged. These protein changes did not appear to be coordinated with transcript levels for any of the AQPs analysed; however, they did occur in parrallel to alterations in water permeability, as well as variations in cell osmolarity, pinitol, glucose, fructose and phosphoenolpyruvate carboxylase (PEPc) levels measured throughout the day/night CAM cycle. Results suggest a role for AQPs in maintaining water balance during CAM and highlight the complexity of protein expression during the CAM cycle. © 2011 Blackwell Publishing Ltd.

  12. Nonlinear dynamics of the CAM circadian rhythm in response to environmental forcing.

    PubMed

    Hartzell, Samantha; Bartlett, Mark S; Virgin, Lawrence; Porporato, Amilcare

    2015-03-07

    Crassulacean acid metabolism (CAM) photosynthesis functions as an endogenous circadian rhythm coupled to external environmental forcings of energy and water availability. This paper explores the nonlinear dynamics of a new CAM photosynthesis model (Bartlett et al., 2014) and investigates the responses of CAM plant carbon assimilation to different combinations of environmental conditions. The CAM model (Bartlett et al., 2014) consists of a Calvin cycle typical of C3 plants coupled to an oscillator of the type employed in the Van der Pol and FitzHugh-Nagumo systems. This coupled system is a function of environmental variables including leaf temperature, leaf moisture potential, and irradiance. Here, we explore the qualitative response of the system and the expected carbon assimilation under constant and periodically forced environmental conditions. The model results show how the diurnal evolution of these variables entrains the CAM cycle with prevailing environmental conditions. While constant environmental conditions generate either steady-state or periodically oscillating responses in malic acid uptake and release, forcing the CAM system with periodic daily fluctuations in light exposure and leaf temperature results in quasi-periodicity and possible chaos for certain ranges of these variables. This analysis is a first step in quantifying changes in CAM plant productivity with variables such as the mean temperature, daily temperature range, irradiance, and leaf moisture potential. Results may also be used to inform model parametrization based on the observed fluctuating regime. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Can light-field photography ease focusing on the scalp and oral cavity?

    PubMed

    Taheri, Arash; Feldman, Steven R

    2013-08-01

    Capturing a well-focused image using an autofocus camera can be difficult in oral cavity and on a hairy scalp. Light-field digital cameras capture data regarding the color, intensity, and direction of rays of light. Having information regarding direction of rays of light, computer software can be used to focus on different subjects in the field after the image data have been captured. A light-field camera was used to capture the images of the scalp and oral cavity. The related computer software was used to focus on scalp or different parts of oral cavity. The final pictures were compared with pictures taken with conventional, compact, digital cameras. The camera worked well for oral cavity. It also captured the pictures of scalp easily; however, we had to repeat clicking between the hairs on different points to choose the scalp for focusing. A major drawback of the system was the resolution of the resulting pictures that was lower than conventional digital cameras. Light-field digital cameras are fast and easy to use. They can capture more information on the full depth of field compared with conventional cameras. However, the resolution of the pictures is relatively low. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. LoCuSS: THE MASS DENSITY PROFILE OF MASSIVE GALAXY CLUSTERS AT z = 0.2 {sup ,}

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Okabe, Nobuhiro; Umetsu, Keiichi; Smith, Graham P.

    We present a stacked weak-lensing analysis of an approximately mass-selected sample of 50 galaxy clusters at 0.15 < z < 0.3, based on observations with Suprime-Cam on the Subaru Telescope. We develop a new method for selecting lensed background galaxies from which we estimate that our sample of red background galaxies suffers just 1% contamination. We detect the stacked tangential shear signal from the full sample of 50 clusters, based on this red sample of background galaxies, at a total signal-to-noise ratio of 32.7. The Navarro-Frenk-White model is an excellent fit to the data, yielding sub-10% statistical precision on massmore » and concentration: M{sub vir}=7.19{sup +0.53}{sub -0.50} Multiplication-Sign 10{sup 14} h{sup -1} M{sub sun}, c{sub vir}=5.41{sup +0.49}{sub -0.45} (c{sub 200}=4.22{sup +0.40}{sub -0.36}). Tests of a range of possible systematic errors, including shear calibration and stacking-related issues, indicate that they are subdominant to the statistical errors. The concentration parameter obtained from stacking our approximately mass-selected cluster sample is broadly in line with theoretical predictions. Moreover, the uncertainty on our measurement is comparable with the differences between the different predictions in the literature. Overall, our results highlight the potential for stacked weak-lensing methods to probe the mean mass density profile of cluster-scale dark matter halos with upcoming surveys, including Hyper-Suprime-Cam, Dark Energy Survey, and KIDS.« less

  15. An electrically tunable plenoptic camera using a liquid crystal microlens array

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lei, Yu; School of Automation, Huazhong University of Science and Technology, Wuhan 430074; Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074

    2015-05-15

    Plenoptic cameras generally employ a microlens array positioned between the main lens and the image sensor to capture the three-dimensional target radiation in the visible range. Because the focal length of common refractive or diffractive microlenses is fixed, the depth of field (DOF) is limited so as to restrict their imaging capability. In this paper, we propose a new plenoptic camera using a liquid crystal microlens array (LCMLA) with electrically tunable focal length. The developed LCMLA is fabricated by traditional photolithography and standard microelectronic techniques, and then, its focusing performance is experimentally presented. The fabricated LCMLA is directly integrated withmore » an image sensor to construct a prototyped LCMLA-based plenoptic camera for acquiring raw radiation of targets. Our experiments demonstrate that the focused region of the LCMLA-based plenoptic camera can be shifted efficiently through electrically tuning the LCMLA used, which is equivalent to the extension of the DOF.« less

  16. Caught on Camera.

    ERIC Educational Resources Information Center

    Milshtein, Amy

    2002-01-01

    Describes the benefits of and rules to be followed when using surveillance cameras for school security. Discusses various camera models, including indoor and outdoor fixed position cameras, pan-tilt zoom cameras, and pinhole-lens cameras for covert surveillance. (EV)

  17. Sandblasting may damage the surface of composite CAD-CAM blocks.

    PubMed

    Yoshihara, Kumiko; Nagaoka, Noriyuki; Maruo, Yukinori; Nishigawa, Goro; Irie, Masao; Yoshida, Yasuhiro; Van Meerbeek, Bart

    2017-03-01

    CAD-CAM blocks to fabricate semi-direct and indirect restorations are available in different sorts of ceramics as well as composite. In order to bond restorations prepared out of composite blocks into tooth cavities, it is recommended to gently sandblast the surface prior to the application of a primer/adhesive. Today, the effect of sandblasting composite block surfaces has not thoroughly been investigated. In this study, the ultra-structure of composite CAD-CAM blocks was investigated with special attention to the effect of sandblasting on the surface topography and of silanization on the bonding performance. Five different composite CAD-CAM blocks were involved. We correlatively investigated their structural and chemical composition using X-ray diffraction (XRD), energy dispersion spectroscopy (EDS), scanning electron microscopy (SEM) and (scanning) transmission electron microscopy ((S)TEM). The effect of sandblasting was also imaged in cross-section and at the interface with composite cement. Finally, we measured the shear bond strength to the sandblasted block surface with and without silanization. All composite blocks revealed a different ultra-structure. Sandblasting increased surface roughness and resulted in an irregular surface with some filler exposure. Sandblasting also damaged the surface. When the sandblasted composite blocks were silanized, superior bonding receptiveness in terms of higher bond strength was achieved except for Shofu Block HC. Sandblasting followed by silanization improved the bond strength to composite CAD-CAM blocks. However, sandblasting may also damage the composite CAD-CAM block surface. For the composite CAD-CAM block Shofu Block HC, the damage was so severe that silanization did not improve bond strength. Copyright © 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  18. A MegaCam Survey of Outer Halo Satellites. I. Description of the Survey

    NASA Astrophysics Data System (ADS)

    Muñoz, Ricardo R.; Côté, Patrick; Santana, Felipe A.; Geha, Marla; Simon, Joshua D.; Oyarzún, Grecco A.; Stetson, Peter B.; Djorgovski, S. G.

    2018-06-01

    We describe a deep, systematic imaging study of satellites in the outer halo of the Milky Way. Our sample consists of 58 stellar overdensities—i.e., substructures classified as either globular clusters, classical dwarf galaxies, or ultra-faint dwarf galaxies—that are located at Galactocentric distances of R GC ≥ 25 kpc (outer halo) and out to ∼400 kpc. This includes 44 objects for which we have acquired deep, wide-field, g- and r-band imaging with the MegaCam mosaic cameras on the 3.6 m Canada–France–Hawaii Telescope and the 6.5 m Magellan-Clay telescope. These data are supplemented by archival imaging, or published gr photometry, for an additional 14 objects, most of which were discovered recently in the Dark Energy Survey (DES). We describe the scientific motivation for our survey, including sample selection, observing strategy, data reduction pipeline, calibration procedures, and the depth and precision of the photometry. The typical 5σ point-source limiting magnitudes for our MegaCam imaging—which collectively covers an area of ≈52 deg2—are g lim ≃ 25.6 and r lim ≃ 25.3 AB mag. These limits are comparable to those from the coadded DES images and are roughly a half-magnitude deeper than will be reached in a single visit with the Large Synoptic Survey Telescope. Our photometric catalog thus provides the deepest and most uniform photometric database of Milky Way satellites available for the foreseeable future. In other papers in this series, we have used these data to explore the blue straggler populations in these objects, their density distributions, star formation histories, scaling relations, and possible foreground structures.

  19. 6. VAL CAMERA CAR, DETAIL OF COMMUNICATION EQUIPMENT INSIDE CAMERA ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. VAL CAMERA CAR, DETAIL OF COMMUNICATION EQUIPMENT INSIDE CAMERA CAR WITH CAMERA MOUNT IN FOREGROUND. - Variable Angle Launcher Complex, Camera Car & Track, CA State Highway 39 at Morris Reservior, Azusa, Los Angeles County, CA

  20. Geometric Calibration and Validation of Ultracam Aerial Sensors

    NASA Astrophysics Data System (ADS)

    Gruber, Michael; Schachinger, Bernhard; Muick, Marc; Neuner, Christian; Tschemmernegg, Helfried

    2016-03-01

    We present details of the calibration and validation procedure of UltraCam Aerial Camera systems. Results from the laboratory calibration and from validation flights are presented for both, the large format nadir cameras and the oblique cameras as well. Thus in this contribution we show results from the UltraCam Eagle and the UltraCam Falcon, both nadir mapping cameras, and the UltraCam Osprey, our oblique camera system. This sensor offers a mapping grade nadir component together with the four oblique camera heads. The geometric processing after the flight mission is being covered by the UltraMap software product. Thus we present details about the workflow as well. The first part consists of the initial post-processing which combines image information as well as camera parameters derived from the laboratory calibration. The second part, the traditional automated aerial triangulation (AAT) is the step from single images to blocks and enables an additional optimization process. We also present some special features of our software, which are designed to better support the operator to analyze large blocks of aerial images and to judge the quality of the photogrammetric set-up.

  1. SenseCam as a rehabilitation tool in a child with anterograde amnesia.

    PubMed

    Pauly-Takacs, Katalin; Moulin, Chris J A; Estlin, Edward J

    2011-10-01

    We present the case of a 13-year-old boy, CJ, with profound episodic memory difficulties following the diagnosis of a metastatic intracranial germ cell tumour and subsequent treatment with radiotherapy and chemotherapy. At the core of this study is the first application of SenseCam to a child with severe memory impairment. CJ was taken for a walk while he was wearing SenseCam. This included visiting four different locations. We manipulated the number of locations he could review on SenseCam "films" and then tested recognition memory (forced choice) for both reviewed and non-reviewed locations. We also collected his justifications for the choices he made. Our results indicate that repeated viewings of SenseCam images support the formation of personal semantic memories. Overall our results suggest that the use of SenseCam in memory rehabilitation extends beyond supporting episodic memory and recollection, and supports the feasibility of its use with children who have marked memory difficulties.

  2. 40 Gbps data acquisition system for NectarCAM

    NASA Astrophysics Data System (ADS)

    Hoffmann, Dirk; Houles, Julien; NectarCAM Team; CTA Consortium, the

    2017-10-01

    The Cherenkov Telescope Array (CTA) will be the next generation ground-based gamma-ray observatory. It will be made up of approximately 100 telescopes of three different sizes, from 4 to 23 meters in diameter. The previously presented prototype of a high speed data acquisition (DAQ) system for CTA (CHEP 2012, [6]) has become concrete within the NectarCAM project, one of the most challenging camera projects with very demanding needs for bandwidth of data handling. We designed a Linux-PC system able to concentrate and process without packet loss the 40 Gb/s average data rate coming from the 265 Front End Boards (FEB) through Gigabit Ethernet links, and to reduce data to fit the two ten-Gigabit Ethernet downstream links by external trigger decisions as well as custom tailored compression algorithms. Within the given constraints, we implemented de-randomisation of the event fragments received as relatively small UDP packets emitted by the FEB, using off-the-shelf equipment as required by the project and for an operation period of at least 30 years. We tested out-of-the-box interfaces and used original techniques to cope with these requirements, and set up a test bench with hundreds of synchronous Gigabit links in order to validate and tune the acquisition chain including downstream data logging based on zeroMQ and Google ProtocolBuffers [8].

  3. The Dutch complementary and alternative medicine (CAM) protocol: to ensure the safe and effective use of complementary and alternative medicine within Dutch mental health care.

    PubMed

    Hoenders, H J Rogier; Appelo, Martin T; van den Brink, Erik H; Hartogs, Bregje M A; de Jong, Joop T V M

    2011-12-01

    Complementary and alternative medicine (CAM) is subject to heated debates and prejudices. Studies show that CAM is widely used by psychiatric patients, usually without the guidance of a therapist and without the use of a solid working method, leading to potential health risks. The purpose of this study is to facilitate the judicious use of CAM alongside conventional psychiatry in an outpatient psychiatric clinic. A search was made through scientific and legal articles and discussion in focus groups. In the Centre for Integrative Psychiatry (CIP) of Lentis in The Netherlands, some carefully selected CAM are offered under strict conditions, alongside conventional treatments. Because of the controversy and the potential health risks, Lentis designed a protocol that is presented. The CIP hopes, by using this protocol, to better serve and respect the individual needs and preferences of the diversity of psychiatric patients in our Dutch multicultural society, and better protect them from harm.

  4. Bonding Effectiveness of Luting Composites to Different CAD/CAM Materials.

    PubMed

    Peumans, Marleen; Valjakova, Emilija Bajraktarova; De Munck, Jan; Mishevska, Cece Bajraktarova; Van Meerbeek, Bart

    To evaluate the influence of different surface treatments of six novel CAD/CAM materials on the bonding effectiveness of two luting composites. Six different CAD/CAM materials were tested: four ceramics - Vita Mark II; IPS Empress CAD and IPS e.max CAD; Celtra Duo - one hybrid ceramic, Vita Enamic, and one composite CAD/CAM block, Lava Ultimate. A total of 60 blocks (10 per material) received various mechanical surface treatments: 1. 600-grit SiC paper; 2. sandblasting with 30-μm Al2O3; 3. tribochemical silica coating (CoJet). Subsequent chemical surface treatments involved either no further treatment (control), HF acid etching (HF), silanization (S, or HF acid etching followed by silanization (HF+S). Two specimens with the same surface treatment were bonded together using two dual-curing luting composites: Clearfil Esthetic Cement (self-etching) or Panavia SA Cement (self-adhesive). After 1 week of water storage, the microtensile bond strength of the sectioned microspecimens was measured and the failure mode was evaluated. The bonding performance of the six CAD/CAM materials was significantly influenced by surface treatment (linear mixed models, p < 0.05). The luting cement had a significant influence on bond strength for Celtra Duo and Lava Ultimate (linear mixed models, p < 0.05). Mechanical surface treatment significantly influenced the bond strength for Celtra Duo (p = 0.0117), IPS e.max CAD (p = 0.0115), and Lava Ultimate (p < 0.0001). Different chemical surface treatments resulted in the highest bond strengths for the six CAD/CAM materials: Vita Mark II and IPS Empress CAD: S, HF+S; Celtra Duo: HF, HF+S; IPS e.max CAD: HF+S; Vita Enamic: HF+S, S. For Lava Ultimate, the highest bond strengths were obtained with HF, S, HF+S. Failure analysis showed a relation between bond strength and failure type: more mixed failures were observed with higher bond strengths. Mainly adhesive failures were noticed if no further surface treatment was done. The percentage of

  5. Improving Formative Assessment in Language Classrooms Using "GradeCam Go!"

    ERIC Educational Resources Information Center

    Kiliçkaya, Ferit

    2017-01-01

    This study aimed to determine EFL (English as a Foreign Language) teachers' perceptions and experience regarding their use of "GradeCam Go!" to grade multiple choice tests. The results of the study indicated that the participants overwhelmingly valued "GradeCam Go!" due to its features such as grading printed forms for…

  6. LAMOST CCD camera-control system based on RTS2

    NASA Astrophysics Data System (ADS)

    Tian, Yuan; Wang, Zheng; Li, Jian; Cao, Zi-Huang; Dai, Wei; Wei, Shou-Lin; Zhao, Yong-Heng

    2018-05-01

    The Large Sky Area Multi-Object Fiber Spectroscopic Telescope (LAMOST) is the largest existing spectroscopic survey telescope, having 32 scientific charge-coupled-device (CCD) cameras for acquiring spectra. Stability and automation of the camera-control software are essential, but cannot be provided by the existing system. The Remote Telescope System 2nd Version (RTS2) is an open-source and automatic observatory-control system. However, all previous RTS2 applications were developed for small telescopes. This paper focuses on implementation of an RTS2-based camera-control system for the 32 CCDs of LAMOST. A virtual camera module inherited from the RTS2 camera module is built as a device component working on the RTS2 framework. To improve the controllability and robustness, a virtualized layer is designed using the master-slave software paradigm, and the virtual camera module is mapped to the 32 real cameras of LAMOST. The new system is deployed in the actual environment and experimentally tested. Finally, multiple observations are conducted using this new RTS2-framework-based control system. The new camera-control system is found to satisfy the requirements for automatic camera control in LAMOST. This is the first time that RTS2 has been applied to a large telescope, and provides a referential solution for full RTS2 introduction to the LAMOST observatory control system.

  7. 2. VAL CAMERA CAR, VIEW OF CAMERA CAR AND TRACK ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. VAL CAMERA CAR, VIEW OF CAMERA CAR AND TRACK WITH CAMERA STATION ABOVE LOOKING WEST TAKEN FROM RESERVOIR. - Variable Angle Launcher Complex, Camera Car & Track, CA State Highway 39 at Morris Reservior, Azusa, Los Angeles County, CA

  8. Comparison of Flexural Strength of Different CAD/CAM PMMA-Based Polymers.

    PubMed

    Alp, Gülce; Murat, Sema; Yilmaz, Burak

    2018-01-28

    To compare the flexural strength of different computer-aided design/computer-aided manufacturing (CAD/CAM) poly(methyl methacrylate)-based (PMMA) polymers and conventional interim resin materials after thermocycling. Rectangular-shaped specimens (n = 15, for each material) (25 × 2 × 2 mm 3 ) were fabricated from 3 CAD/CAM PMMA-based polymers (Telio CAD [T]; M-PM-Disc [M]; Polident-PMMA [P]), 1 bis-acrylate composite resin (Protemp 4 [PT]), and 1 conventional PMMA (ArtConcept Artegral Dentine [C]) according to ISO 10477:2004 Standards (Dentistry-Polymer-Based Crown and Bridge Materials). The specimens were subjected to 10,000 thermocycles (5 to 55°C). Three-point flexural strength of the specimens was tested in a universal testing machine at a 1.0 mm/min crosshead speed, and the flexural strength data (σ) were calculated (MPa). The flexural strength values were statistically analyzed using 1-way ANOVA, and Tukey HSD post-hoc test for multiple comparisons (α = 0.05). Flexural strength values ranged between 66.1 ± 13.1 and 131.9 ± 19.8 MPa. There were significant differences among the flexural strengths of tested materials, except for between T and P CAD/CAM PMMA-based polymers (p > 0.05). CAD/CAM PMMA-based polymer M had the highest flexural strength and conventional PMMA had the lowest (p < 0.05). CAD/CAM PMMA-based T and P polymers had significantly higher flexural strength than the bis-acrylate composite resin (p < 0.05), and conventional PMMA (p < 0.0001), and significantly lower flexural strength compared to CAD/CAM PMMA-based M (p < 0.05). The flexural strength of CAD/CAM PMMA-based polymers was greater than the flexural strength of bis-acrylate composite resin, which had a greater flexural strength compared to conventional PMMA resin. © 2018 by the American College of Prosthodontists.

  9. An automated qualification framework for the MeerKAT CAM (Control-And-Monitoring)

    NASA Astrophysics Data System (ADS)

    van den Heever, Lize; Marais, Neilen; Slabber, Martin

    2016-08-01

    This paper introduces and discusses the design of an Automated Qualification Framework (AQF) that was developed to automate as much as possible of the formal Qualification Testing of the Control And Monitoring (CAM) subsystem of the 64 dish MeerKAT radio telescope currently under construction in the Karoo region of South Africa. The AQF allows each Integrated CAM Test to reference the MeerKAT CAM requirement and associated verification requirement it covers and automatically produces the Qualification Test Procedure and Qualification Test Report from the test steps and evaluation steps annotated in the Integrated CAM Tests. The MeerKAT System Engineers are extremely happy with the AQF results, but mostly by the approach and process it enforces.

  10. Do CAD/CAM dentures really release less monomer than conventional dentures?

    PubMed

    Steinmassl, Patricia-Anca; Wiedemair, Verena; Huck, Christian; Klaunzer, Florian; Steinmassl, Otto; Grunert, Ingrid; Dumfahrt, Herbert

    2017-06-01

    Computer-aided design (CAD)/computer-aided manufacturing (CAM) dentures are assumed to have more favourable material properties than conventionally fabricated dentures, among them a lower methacrylate monomer release. The aim of this study was to test this hypothesis. CAD/CAM dentures were generated from ten different master casts by using four different CAD/CAM systems. Conventional, heat-polymerised dentures served as control group. Denture weight and volume were measured; the density was calculated, and the denture surface area was assessed digitally. The monomer release after 7 days of water storage was measured by high-performance liquid chromatography. Whole You Nexteeth and Wieland Digital Dentures had significantly lower mean volume and weight than conventional dentures. Baltic Denture System and Whole You Nexteeth had a significantly increased density. Baltic Denture System had a significantly smaller surface area. None of the CAD/CAM dentures released significantly less monomer than the control group. All tested dentures released very low amounts of methacrylate monomer, but not significantly less than conventional dentures. A statistically significant difference might nevertheless exist in comparison to other, less recommendable denture base materials, such as the frequently used autopolymerising resins. CAD/CAM denture fabrication has numerous advantages. It enables the fabrication of dentures with lower resin volume and lower denture weight. Both could increase the patient comfort. Dentures with higher density might exhibit more favourable mechanical properties. The hypothesis that CAD/CAM dentures release less monomer than conventional dentures could, however, not be verified.

  11. N-glycosylation at the SynCAM (synaptic cell adhesion molecule) immunoglobulin interface modulates synaptic adhesion.

    PubMed

    Fogel, Adam I; Li, Yue; Giza, Joanna; Wang, Qing; Lam, Tukiet T; Modis, Yorgo; Biederer, Thomas

    2010-11-05

    Select adhesion molecules connect pre- and postsynaptic membranes and organize developing synapses. The regulation of these trans-synaptic interactions is an important neurobiological question. We have previously shown that the synaptic cell adhesion molecules (SynCAMs) 1 and 2 engage in homo- and heterophilic interactions and bridge the synaptic cleft to induce presynaptic terminals. Here, we demonstrate that site-specific N-glycosylation impacts the structure and function of adhesive SynCAM interactions. Through crystallographic analysis of SynCAM 2, we identified within the adhesive interface of its Ig1 domain an N-glycan on residue Asn(60). Structural modeling of the corresponding SynCAM 1 Ig1 domain indicates that its glycosylation sites Asn(70)/Asn(104) flank the binding interface of this domain. Mass spectrometric and mutational studies confirm and characterize the modification of these three sites. These site-specific N-glycans affect SynCAM adhesion yet act in a differential manner. Although glycosylation of SynCAM 2 at Asn(60) reduces adhesion, N-glycans at Asn(70)/Asn(104) of SynCAM 1 increase its interactions. The modification of SynCAM 1 with sialic acids contributes to the glycan-dependent strengthening of its binding. Functionally, N-glycosylation promotes the trans-synaptic interactions of SynCAM 1 and is required for synapse induction. These results demonstrate that N-glycosylation of SynCAM proteins differentially affects their binding interface and implicate post-translational modification as a mechanism to regulate trans-synaptic adhesion.

  12. N-Glycosylation at the SynCAM (Synaptic Cell Adhesion Molecule) Immunoglobulin Interface Modulates Synaptic Adhesion*

    PubMed Central

    Fogel, Adam I.; Li, Yue; Giza, Joanna; Wang, Qing; Lam, TuKiet T.; Modis, Yorgo; Biederer, Thomas

    2010-01-01

    Select adhesion molecules connect pre- and postsynaptic membranes and organize developing synapses. The regulation of these trans-synaptic interactions is an important neurobiological question. We have previously shown that the synaptic cell adhesion molecules (SynCAMs) 1 and 2 engage in homo- and heterophilic interactions and bridge the synaptic cleft to induce presynaptic terminals. Here, we demonstrate that site-specific N-glycosylation impacts the structure and function of adhesive SynCAM interactions. Through crystallographic analysis of SynCAM 2, we identified within the adhesive interface of its Ig1 domain an N-glycan on residue Asn60. Structural modeling of the corresponding SynCAM 1 Ig1 domain indicates that its glycosylation sites Asn70/Asn104 flank the binding interface of this domain. Mass spectrometric and mutational studies confirm and characterize the modification of these three sites. These site-specific N-glycans affect SynCAM adhesion yet act in a differential manner. Although glycosylation of SynCAM 2 at Asn60 reduces adhesion, N-glycans at Asn70/Asn104 of SynCAM 1 increase its interactions. The modification of SynCAM 1 with sialic acids contributes to the glycan-dependent strengthening of its binding. Functionally, N-glycosylation promotes the trans-synaptic interactions of SynCAM 1 and is required for synapse induction. These results demonstrate that N-glycosylation of SynCAM proteins differentially affects their binding interface and implicate post-translational modification as a mechanism to regulate trans-synaptic adhesion. PMID:20739279

  13. Consistency between the global and regional modeling components of CAMS over Europe.

    NASA Astrophysics Data System (ADS)

    Katragkou, Eleni; Akritidis, Dimitrios; Kontos, Serafim; Zanis, Prodromos; Melas, Dimitrios; Engelen, Richard; Plu, Matthieu; Eskes, Henk

    2017-04-01

    The Copernicus Atmosphere Monitoring Service (CAMS) is a component of the European Earth Observation programme Copernicus. CAMS consists of two major forecast and analysis systems: i) the CAMS global near-real time service, based on the ECMWF Integrated Forecast System (C-IFS), which provides daily analyses and forecasts of reactive trace gases, greenhouse gases and aerosol concentrations ii) a regional ensemble (ENS) for European air quality, compiled and disseminated by Météo-France, which consists of seven ensemble members. The boundaries from the regional ensemble members are extracted from the global CAMS forecast product. This work reports on the consistency between the global and regional modeling components of CAMS, and the impact of global CAMS boundary conditions on regional forecasts. The current analysis includes ozone (O3) carbon monoxide (CO) and aerosol (PM10/PM2.5) forecasts. The comparison indicates an overall good agreement between the global C-IFS and the regional ENS patterns for O3 and CO, especially above 250m altitude, indicating that the global boundary conditions are efficiently included in the regional ensemble simulations. As expected, differences are found within the PBL, with lower/higher C-IFS O3/CO concentrations over continental Europe with respect to ENS.

  14. 1. VARIABLEANGLE LAUNCHER CAMERA CAR, VIEW OF CAMERA CAR AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. VARIABLE-ANGLE LAUNCHER CAMERA CAR, VIEW OF CAMERA CAR AND TRACK WITH CAMERA STATION ABOVE LOOKING NORTH TAKEN FROM RESERVOIR. - Variable Angle Launcher Complex, Camera Car & Track, CA State Highway 39 at Morris Reservior, Azusa, Los Angeles County, CA

  15. 21 CFR 872.3661 - Optical Impression Systems for CAD/CAM.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Optical Impression Systems for CAD/CAM. 872.3661 Section 872.3661 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Design and Manufacturing (CAD/CAM) of Dental Restorations; Guidance for Industry and FDA.” For the...

  16. Understanding dental CAD/CAM for restorations--the digital workflow from a mechanical engineering viewpoint.

    PubMed

    Tapie, L; Lebon, N; Mawussi, B; Fron Chabouis, H; Duret, F; Attal, J-P

    2015-01-01

    As digital technology infiltrates every area of daily life, including the field of medicine, so it is increasingly being introduced into dental practice. Apart from chairside practice, computer-aided design/computer-aided manufacturing (CAD/CAM) solutions are available for creating inlays, crowns, fixed partial dentures (FPDs), implant abutments, and other dental prostheses. CAD/CAM dental solutions can be considered a chain of digital devices and software for the almost automatic design and creation of dental restorations. However, dentists who want to use the technology often do not have the time or knowledge to understand it. A basic knowledge of the CAD/CAM digital workflow for dental restorations can help dentists to grasp the technology and purchase a CAM/CAM system that meets the needs of their office. This article provides a computer-science and mechanical-engineering approach to the CAD/CAM digital workflow to help dentists understand the technology.

  17. Mutation of EpCAM leads to intestinal barrier and ion transport dysfunction.

    PubMed

    Kozan, Philip A; McGeough, Matthew D; Peña, Carla A; Mueller, James L; Barrett, Kim E; Marchelletta, Ronald R; Sivagnanam, Mamata

    2015-05-01

    Congenital tufting enteropathy (CTE) is a devastating diarrheal disease seen in infancy that is typically associated with villous changes and the appearance of epithelial tufts. We previously found mutations in epithelial cell adhesion molecule (EpCAM) to be causative in CTE. We developed a knock-down cell model of CTE through transfection of an EpCAM shRNA construct into T84 colonic epithelial cells to elucidate the in vitro role of EpCAM in barrier function and ion transport. Cells with EpCAM deficiency exhibited decreased electrical resistance, increased permeability, and decreased ion transport. Based on mutations in CTE patients, an in vivo mouse model was developed, with tamoxifen-inducible deletion of exon 4 in Epcam resulting in mutant protein with decreased expression. Tamoxifen treatment of Epcam (Δ4/Δ4) mice resulted in pathological features of villous atrophy and epithelial tufts, similar to those in human CTE patients, within 4 days post induction. Epcam (Δ4/Δ4) mice also showed decreased expression of tight junctional proteins, increased permeability, and decreased ion transport in the intestines. Taken together, these findings reveal mechanisms that may underlie disease in CTE. Knock-down EpCAM cell model of congenital tufting enteropathy was developed. In vivo inducible mouse model was developed resulting in mutant EpCAM protein. Cells with EpCAM deficiency demonstrated barrier and ion transport dysfunction. Tamoxifen-treated Epcam (Δ4/Δ4) mice demonstrated pathological features. Epcam (Δ4/Δ4) mice showed improper barrier function and ion transport.

  18. Analysis of Camera Arrays Applicable to the Internet of Things.

    PubMed

    Yang, Jiachen; Xu, Ru; Lv, Zhihan; Song, Houbing

    2016-03-22

    The Internet of Things is built based on various sensors and networks. Sensors for stereo capture are essential for acquiring information and have been applied in different fields. In this paper, we focus on the camera modeling and analysis, which is very important for stereo display and helps with viewing. We model two kinds of cameras, a parallel and a converged one, and analyze the difference between them in vertical and horizontal parallax. Even though different kinds of camera arrays are used in various applications and analyzed in the research work, there are few discussions on the comparison of them. Therefore, we make a detailed analysis about their performance over different shooting distances. From our analysis, we find that the threshold of shooting distance for converged cameras is 7 m. In addition, we design a camera array in our work that can be used as a parallel camera array, as well as a converged camera array and take some images and videos with it to identify the threshold.

  19. Critical review of complementary and alternative medicine use in menopause: focus on prevalence, motivation, decision-making, and communication.

    PubMed

    Peng, Wenbo; Adams, Jon; Sibbritt, David W; Frawley, Jane E

    2014-05-01

    This study aims to undertake the first critical review of complementary and alternative medicine (CAM) use among menopausal women (a term here used to include premenopausal, perimenopausal and postmenopausal women) by focusing on the prevalence of CAM use and CAM users' characteristics, motivation, decision-making, and communication with healthcare providers. A comprehensive search of 2002-2012 international literature in the Medline, CINAHL, AMED, and SCOPUS databases was conducted. The search was confined to peer-reviewed articles published in English with abstracts and reporting new empirical research findings regarding CAM use and menopause. A considerable level of CAM use was observed among women in menopause. Many menopausal women use CAM concurrently with their conventional medicine. However, communication regarding CAM between menopausal women and healthcare providers seems less than optimal, with a demand for further information on the safety and efficacy of medicines. Existing literature is of variable methodological rigor, often presenting small sample sizes and low-quality data collection. Further rigorous research on this topic-including quantitative and qualitative methods using large national samples, where relevant-is required. The findings of this critical review provide insights for those practicing and managing health care in this area of women's health. Healthcare providers should prepare to inform menopausal women about all treatment options, including CAM, and should be aware of the possible adverse effects of CAM and potential interactions between CAM and conventional medicine among women in menopause who are under their care.

  20. Cam type femoro-acetabular impingement: quantifying the diagnosis using three dimensional head-neck ratios.

    PubMed

    Masjedi, Milad; Marquardt, Charles S; Drummond, Isabella M H; Harris, Simon J; Cobb, Justin P

    2013-03-01

    Cam hips are commonly quantified using the two-dimensional α angle. The accuracy of this measurement may be affected by patient position and the technician's experience. In this paper, we describe a method of measurement that provides a quantitative definition of cam hips based upon three-dimensional computed tomography (CT) images. CT scans of 47 (24 cam, 23 normal) femurs were segmented. A sphere was fitted to the articulating surface of the femoral head, the radius (r) recorded, and the femoral neck axis obtained. The cross sectional area at four locations spanning the head neck junction (r/4, r/2, 3r/4 and r), perpendicular to the neck axis, was measured. The ratios (Neck/Head) between the areas at each cut relative to the surface area at the head centre were calculated and aggregated. Normal and cam hips were significantly different: the sum of the head-neck ratios (HNRs) of the cam hips were always smaller than normal hips (p < 0.01). A cut off point of 2.55 with no overlap was found between the two groups, with HNRs larger than this being cam hips, and smaller being normal ones. Owing to its sensitivity and repeatability, the method could be used to confirm or refute the clinical diagnosis of a cam hip. Furthermore it can be used as a tool to measure the outcome of cam surgery.