Sample records for gore viabahn endoprosthesis

  1. Three-year results of the VIBRANT trial of VIABAHN endoprosthesis versus bare nitinol stent implantation for complex superficial femoral artery occlusive disease.

    PubMed

    Geraghty, Patrick J; Mewissen, Mark W; Jaff, Michael R; Ansel, Gary M

    2013-08-01

    The predominant mode of bare nitinol stent failure is diffuse in-stent restenosis, and failure rates correlate to the length and complexity of the treated lesion. Addition of an expanded polytetrafluoroethylene lining to a nitinol stent frame, as found in the VIABAHN endoprosthesis, mitigates the ingrowth of intimal hyperplasia. We compared the long-term outcomes of complex superficial femoral artery disease intervention using the VIABAHN endoprosthesis to those obtained with bare nitinol stent implantation. One hundred forty-eight patients with symptomatic complex superficial femoral artery disease (TransAtlantic Inter-Society Consensus I class C and D lesions, accompanied by intermittent claudication or ischemic rest pain) were randomized to endovascular intervention using either bare nitinol stent implantation (76 patients) or nonheparin-bonded VIABAHN endoprosthesis deployment (72 patients). Patency, limb hemodynamics, and quality of life were evaluated at 1, 6, 12, 24, and 36 months following intervention. The average treated lesion measured 18 ± 8 cm in length, and 58.8% of lesions displayed segmental or complete occlusion. At 3 years, primary patency rates (defined by peak systolic velocity ratio ≤ 2.0 and no target lesion revascularization) did not significantly differ between patients treated with the VIABAHN stent graft and those who received a bare nitinol stent (24.2% vs 25.9%; P = .392). Stent fractures were significantly more common in bare nitinol stents (50.0%) than in the VIABAHN endoprostheses (2.6%). Primary-assisted patency rates were higher in those receiving bare nitinol stents than the VIABAHN stent graft (88.8% vs 69.8%; P = .04), although secondary patency rates did not differ between bare nitinol stent and stent graft recipients (89.3% vs 79.5%; P = .304). There were no instances of procedure-related mortality or amputation. The hemodynamic improvement and quality measures improved equally in both groups. The long-term outcomes of

  2. Heparin-bonded covered stents versus bare-metal stents for complex femoropopliteal artery lesions: the randomized VIASTAR trial (Viabahn endoprosthesis with PROPATEN bioactive surface [VIA] versus bare nitinol stent in the treatment of long lesions in superficial femoral artery occlusive disease).

    PubMed

    Lammer, Johannes; Zeller, Thomas; Hausegger, Klaus A; Schaefer, Philipp J; Gschwendtner, Manfred; Mueller-Huelsbeck, Stefan; Rand, Thomas; Funovics, Martin; Wolf, Florian; Rastan, Aljoscha; Gschwandtner, Michael; Puchner, Stefan; Ristl, Robin; Schoder, Maria

    2013-10-08

    lesions in the TPP analysis. In the ITT analysis for all lesions, which was flawed by major protocol deviations in 8.5% of the patients, the difference was not significant. (GORE VIABAHN® endoprosthesis with bioactive propaten surface versus bare nitinol stent in the treatment of TASC B, C and D lesions in superficial femoral artery occlusive disease; ISRCTN48164244). Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  3. Heparin-bonded, expanded polytetrafluoroethylene-lined stent graft in the treatment of femoropopliteal artery disease: 1-year results of the VIPER (Viabahn Endoprosthesis with Heparin Bioactive Surface in the Treatment of Superficial Femoral Artery Obstructive Disease) trial.

    PubMed

    Saxon, Richard R; Chervu, Arun; Jones, Paul A; Bajwa, Tanvir K; Gable, Dennis R; Soukas, Peter A; Begg, Richard J; Adams, John G; Ansel, Gary M; Schneider, Darren B; Eichler, Charles M; Rush, Michael J

    2013-02-01

    To evaluate the performance of a heparin-bonded, expanded polytetrafluoroethylene (ePTFE)-lined nitinol endoprosthesis in the treatment of long-segment occlusive disease of the femoropopliteal artery (FPA) and to identify factors associated with loss of patency. In a single-arm, prospective, 11-center study (VIPER [Gore Viabahn Endoprosthesis with Heparin Bioactive Surface in the Treatment of Superficial Femoral Artery Obstructive Disease] trial), 119 limbs (113 patients; 69 men; mean age, 67 y), including 88 with Rutherford category 3-5 disease and 72 with Inter-Society Consensus for the Management of Peripheral Arterial Disease (TASC II) C or D lesions of the FPA, underwent stent graft implantation. The mean lesion length was 19 cm; 56% of lesions were occlusions. Follow-up evaluations included color duplex ultrasonography in all patients, with patency defined as a peak systolic velocity ratio< 2.5. At 12 months, Rutherford category and ankle-brachial index (ABI) were significantly improved (mean category improvement, 2.4; ABI increased from 0.6±0.2 to 0.9±0.19; P<.0001). Primary and secondary patency rates were 73% and 92%. The primary patency for devices oversized<20% at the proximal landing zone was 88%, whereas the primary patency for devices oversized by>20% was 70% (P = .047). Primary patency was not significantly affected by device diameter (5 vs 6 vs 7 mm) or lesion length (≤20 cm vs>20 cm). The 30-day major adverse event rate was 0.8%. The heparin-bonded, ePTFE/nitinol stent graft provided clinical improvement and a primary patency rate of 73% at 1 year in the treatment of long-segment FPA disease. Careful sizing of the device relative to vessel landing zones is essential for achieving optimal outcomes. Copyright © 2013 SIR. Published by Elsevier Inc. All rights reserved.

  4. Early outcomes of thoracic endovascular stent-graft repair for acute complicated type B dissection using the Gore TAG endoprosthesis.

    PubMed

    Pearce, Benjamin J; Passman, Marc A; Patterson, Mark A; Taylor, Steve M; Lecroy, Christopher J; Combs, Bart R; Jordan, William D

    2008-11-01

    We assessed the technical success and early outcome of thoracic endovascular aortic repair (TEVAR) for complicated acute type B thoracic aortic dissection treated at a single institution using a commercially available device. All patients with symptomatic complicated acute type B thoracic aortic dissection treated with TEVAR since Food and Drug Administration approval of the Gore (Flagstaff, AZ) TAG endoprosthesis were identified from a prospectively maintained vascular registry. Clinical indications, operative technique, perioperative complications, follow-up imaging, and mortality were analyzed. Between March 2005 and November 2007, 127 TEVARs using the TAG endoprosthesis were performed, of which 15 (11.8%) were for complicated acute type B thoracic aortic dissection. Indications for repair were malperfusion (53%), persistent pain (27%), and primary aortic failure (33%). Technical feasibility and success with deployment proximal to the entry tear was 93.3%, requiring at least partial coverage of the left subclavian artery in seven (46.7%). Adjunctive procedures required at the time of TEVAR included renal stent (n = 2), iliac stent (n = 3), and access-artery open repair (n = 2). Twelve patients (80%) had immediate resolution of the malperfusion deficit. Major perioperative complications included paraplegia (13.3%), renal failure requiring hemodialysis (13.3%), and stroke (6.7%). Perioperative mortality was 13.3%, occurring in one patient presenting with rupture and one with profound heart failure on admission. For complicated acute type B thoracic aortic dissection, TEVAR using commercially available stent grafts showed high technical success, excellent results at resolving malperfusion, and acceptably low complications and perioperative mortality.

  5. Prospective, multicenter study of endovascular repair of aortoiliac and iliac aneurysms using the Gore Iliac Branch Endoprosthesis.

    PubMed

    Schneider, Darren B; Matsumura, Jon S; Lee, Jason T; Peterson, Brian G; Chaer, Rabih A; Oderich, Gustavo S

    2017-09-01

    The GORE EXCLUDER Iliac Branch Endoprosthesis (IBE; W. L. Gore and Associates, Flagstaff, Ariz) is an iliac branch stent graft system designed to preserve internal iliac artery perfusion during endovascular repair of aortoiliac aneurysms (AIAs) and common iliac artery (CIA) aneurysms (CIAAs). We report the 6-month primary end point results of the IBE 12-04 United States pivotal trial for endovascular treatment of AIAs and CIAAs using the IBE device. The trial prospectively enrolled 63 patients with AIA or CIAA who underwent implantation of the IBE device at 28 centers in the United States from 2013 to 2015. All patients underwent placement of a single IBE device. Twenty-two patients (34.9%) with bilateral CIAs were enrolled after undergoing staged coil or plug embolization (21 of 22) or surgical revascularization (1 of 22) of the contralateral internal iliac artery. Follow-up at 30 days and 6 months included clinical assessment and computed tomography angiography evaluation as assessed by an independent core laboratory. The primary effectiveness end point was freedom from IBE limb occlusion and reintervention for type I or III endoleak and ≥60% stenosis at 6 months, and the secondary effectiveness end point was freedom from new onset of buttock claudication on the IBE side at 6 months. Mean CIA diameter on the IBE side was 41.0 ± 11.4 mm (range, 25.2-76.3 mm). There were no procedural deaths, and technical success, defined as successful deployment and patency of all IBE components and freedom from type I or III endoleak, was 95.2% (60 of 63). Data for 61 patients were available for primary and secondary effectiveness end point analysis. Internal iliac limb patency was 95.1% (58 of 61), and no new type I or III endoleaks or device migrations were observed at 6 months. The three patients with loss of internal iliac limb patency were asymptomatic, and freedom from new-onset buttock claudication on the IBE side was 100% at 6 months. New-onset buttock

  6. Traveltime characteristics of Gore Creek and Black Gore Creek, upper Colorado River basin, Colorado

    USGS Publications Warehouse

    Gurdak, Jason J.; Spahr, Norman E.; Szmajter, Richard J.

    2002-01-01

    In the Rocky Mountains of Colorado, major highways are often constructed in stream valleys. In the event of a vehicular accident involving hazardous materials, the close proximity of highways to the streams increases the risk of contamination entering the streams. Recent population growth has contributed to increased traffic volume along Colorado highways and has resulted in increased movement of hazardous materials, particularly along Interstate 70. Gore Creek and its major tributary, Black Gore Creek, are vulnerable to such contamination from vehicular accidents along Interstate 70. Gore Creek, major tributary of the Eagle River, drains approximately 102 square miles, some of which has recently undergone significant urban development. The headwaters of Gore Creek originate in the Gore Range in the eastern part of the Gore Creek watershed. Gore Creek flows west to the Eagle River. Beginning at the watershed boundary on Vail Pass, southeast of Vail Ski Resort, Interstate 70 parallels Black Gore Creek and then closely follows Gore Creek the entire length of the watershed. Interstate 70 crosses Gore Creek and tributaries 20 times in the watershed. In the event of a vehicular accident involving a contaminant spill into Gore Creek or Black Gore Creek, a stepwise procedure has been developed for water-resource managers to estimate traveltimes of the leading edge and peak concentration of a conservative contaminant. An example calculating estimated traveltimes for a hypothetical contaminant release in Black Gore Creek is provided. Traveltime measurements were made during May and September along Black Gore Creek and Gore Creek from just downstream from the Black Lakes to the confluence with the Eagle River to account for seasonal variability in stream discharge. Fluorometric dye injection of rhodamine WT and downstream dye detection by fluorometry were used to measure traveltime characteristics of Gore Creek and Black Gore Creek. During the May traveltime measurements

  7. Cephalic Arch Stenosis in Autogenous Haemodialysis Fistulas: Treatment With the Viabahn Stent-Graft

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shawyer, Andrew, E-mail: andrew.shawyer@bartsandthelondon.nhs.uk; Fotiadis, Nicos I., E-mail: fotiadis.nicholas@gmail.com; Namagondlu, Girish, E-mail: girish.namagondlu@bartsandthelondon.nhs.uk

    2013-02-15

    Cephalic arch stenosis (CAS) is an important and common cause of dysfunction in autogenous haemodialysis fistulas that requires multiple reinterventions and aggressive surveillance. We evaluated the safety and efficacy of the Viabahn stent-graft for the management of CAS. Between April 2005 and October 2011, 11 consecutive patients [four men and seven women (mean age 56.7 years)] with CAS and dysfunctional fistulas were treated with insertion of 11 Viabahn stent-grafts. Six stent-grafts were inserted due to residual stenosis after angioplasty and five for fistuloplasty-induced rupture. No patient was lost to follow-up. The technical and clinical success rate was 100 %. Primarymore » access patency rates were 81.8 % [95 % confidence interval (CI) 0.482-0.977] at 6 months and 72.7 % (95 % CI 0.390-0.939) at 12 months. Secondary access patency rates were 90.9 % at 6 months (95 % CI 0.587-0.997). There were no procedure-related complications. Mean follow-up was 543.8 days (range 156-2,282). The use of the Viabahn stent-graft in the management of CAS is technically feasible and, in this small series, showed patency rates that compare favorably with historical data of angioplasty and bare stents.« less

  8. The modular endoprosthesis for mandibular body replacement. Part 2: finite element analysis of endoprosthesis reconstruction of the mandible.

    PubMed

    Wong, Raymond C W; Tideman, Henk; Merkx, Matthias A W; Jansen, John; Goh, Suk Ming

    2012-12-01

    Problems with loosening of the modules for the modular endoprosthesis were encountered in animal studies for mandibular body replacement. We performed a finite element analysis to look at the stress distribution and areas of stress concentration in a human sized mandible. Variations were made to the stem and defect length to look at how the forces changed. The hypothesis was: (1) reconstruction with a modular endoprosthesis did not lead to areas of stress concentration beyond the material strength of cortical bone and titanium alloy; (2) changes in dimensions of the endoprosthesis did not cause a corresponding linear increase to the stresses. The endoprosthesis was modelled to create a male, female part with stems and a connection screw (Case I). The stem length was halved (Case II) and defect length doubled (Case III). Geometric data of a human sized mandible were obtained, a continuity defect created digitally at the right molar area and the models combined. Boundary conditions were set and the model loaded to get a bite force of 300 N at the incisor region. An intact mandible was used as a control. The right side of the reconstructed mandible became less rigid and flexed more. The highest stresses were within the endoprosthesis at two areas of stress concentration: (1) shear stress at the superior surface of the stems close to the junction of the stem and the module body; (2) compressive stresses at the bottom bevel of the dove-tailed connection. The stress distribution for Case I and II did not differ much except for the magnitude which was slightly higher for Case II. There was a tendency for outward bending at the module connection for Case III which potentially might cause loosening of the module connection. Displacements of the mandible were less than 1 mm throughout. The endoprosthesis with its present dimensions would be expected to perform adequately at a bite force of 300 N. An increase in defect length caused a tendency for bending at the stem and the

  9. Infective complications following tumour endoprosthesis surgery for bone and soft tissue tumours.

    PubMed

    Peel, T; May, D; Buising, K; Thursky, K; Slavin, M; Choong, P

    2014-09-01

    This study aims to describe the incidence of infective complications, including tumour endoprosthesis infection, in a cohort of patients undergoing tumour endoprosthesis surgery in Victoria, Australia. This retrospective cohort study was performed over 15 years (January 1996-December 2010). 121 patients underwent tumour endoprosthesis surgery during the study period. Patients were followed for a median of 34 months (interquartile range [IQR] 17, 80). Overall, 34 patients (28%) experienced infective complications including: bacteraemia in 19 patients (16%) and tumour endoprosthesis infection in 17 (14%). The majority of patients with early and late acute infections (haematogenous) were managed with debridement and retention of the prosthesis in addition to biofilm-active antibiotics. Late chronic infections were predominantly managed by exchange of the prosthesis. The overall success rate of treatment was 71%. The success rate for debridement and retention was 75% compared with 67% for exchange procedures. There is a significant rate of infective complications following tumour endoprosthesis surgery including 14% of patients experiencing infection involving the tumour endoprosthesis. This study is the first to report on outcomes from debridement and retention of the prosthesis; which had comparable success rates to other treatment modalities. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  10. New lumbar disc endoprosthesis applied to the patient's anatomic features.

    PubMed

    Mróz, Adrian; Skalski, Konstanty; Walczyk, Wojciech

    2015-01-01

    The paper describes the process of designing, manufacturing and design verification of the intervertebral of a new structure of lumbar disc endoprosthesis - INOP/LSP.1101. Modern and noninvasive medical imagining techniques, make it possible to record results of tests in a digital form, which creates opportunities for further processing. Mimics Innovation Suite software generates three-dimensional virtual models reflecting the real shape and measurements of components of L4-L5 spinal motion segment. With the use of 3D Print technique, physical models of bone structures of the mobile segment of the spine as well as the INOP/LSP.1101 endoprosthesis model were generated. A simplified FEA analysis of stresses in the endoprosthesis was performed to evaluate the designed geometries and materials of the new structure. The endoprosthesis prototype was made of Co28Cr6Mo alloy with the use of selective laser technology. The prototypes were subject to tribological verification with the use of the SBT-03.1 spine simulator. The structure of the endoprosthesis ensures a full reflection of its kinematics, full range of mobility of the motion segment in all anatomical planes as well as restoration of a normal height of the intervertebral space and curvature of the lordosis. The results of the tribological tests confirmed that SLM technology has the potential for production of the human bone and jointendoprostheses.

  11. John Ellard Gore: "Giant Suns and Miniature Stars"

    NASA Astrophysics Data System (ADS)

    Holberg, Jay B.

    2007-12-01

    The Irish amateur astronomer John Ellard Gore (1845-1910) was a founding member of the British Astronomical Association and a prolific author of popular astronomy between 1880 and 1910. He is perhaps best remembered for his books `The Visible Universe’ (1893), an English language translation of Camille Flammarion's `Popular Astronomy’ (1894) and his contributions to Agnes Clerk's `Astronomy’ (1898). I consider a little known investigation that Gore undertook into the question of stellar `sizes’ using binary stars. This led him to the realization of the existence of "Giant Suns” as well as "Miniature Stars” the latter included the sun. Gore also considered the existence of hyper-dense compact objects, now known as white dwarfs. Unfortunately Gore rejected the reality of the latter stellar types. Gore based his conclusions on a formula developed by fellow Irish astronomer W.H.S. Monck, who was reaching similar conclusions about Giant stars through the study of stellar motions.

  12. The Gore/Bush Records on Higher Education.

    ERIC Educational Resources Information Center

    Walters, Ronald

    2000-01-01

    Compares the records of presidential candidates George W. Bush and Al Gore on higher education issues and, specifically, those of interest to the Black community. Concludes that Al Gore's record makes him an overall better choice in the 2000 campaign. (DB)

  13. Modeling knee joint endoprosthesis mode of deformation

    NASA Astrophysics Data System (ADS)

    Skeeba, V. Yu; Ivancivsky, V. V.

    2018-03-01

    The purpose of the work was to define the efficient design of the endoprosthesis, working in a multiple-cycle loading environment. Methodology and methods: triangulated surfaces of the base contact surfaces of endoprosthesis butt elements have been created using the PowerShape and SolidWorks software functional environment, and the assemblies of the possible combinations of the knee joint prosthetic designs have been prepared. The mode of deformation modeling took place in the multipurpose program complex ANSYS. Results and discussion: as a result of the numerical modeling, the following data were obtained for each of the developed knee joint versions: the distribution fields of absolute (total) and relative deformations; equivalent stress distribution fields; fatigue strength coefficient distribution fields. In the course of the studies, the following efficient design assembly has been established: 1) Ti-Al-V alloy composite femoral component with polymer inserts; 2) ceramic liners of the compound separator; 3) a Ti-Al-V alloy composite tibial component. The fatigue strength coefficient for the femoral component is 4.2; for the femoral component polymer inserts is 1.2; for the ceramic liners of the compound separator is 3.1; for the tibial component is 2.7. This promising endoprosthesis structure is recommended for further design and technological development.

  14. Student Town Meeting with Vice President Al Gore. Teacher's Guide.

    ERIC Educational Resources Information Center

    Edwards, Amy N.

    This teacher's guide accompanies a videotape of the same name. Vice President Albert Gore, Jr., discusses current issues with students who question Mr. Gore on such topics as the environment, reinventing government, voter participation, crime, and the United States' role in foreign affairs. Gore tailors his answers to the teenage audience as the…

  15. Development of Aluminum-Lithium 2195 Gores by the Stretch Forming Process

    NASA Technical Reports Server (NTRS)

    Volz, M. P.; Chen, P. S.; Gorti, S.; Salvail, P.

    2014-01-01

    Aluminum-Lithium alloy 2195 exhibits higher mechanical properties and lower density than aluminum alloy 2219, which is the current baseline material for Space Launch System (SLS) cryogenic tank components. Replacement of Al 2219 with Al-Li 2195 would result in substantial weight savings, as was the case when this replacement was made on the shuttle external tank. A key component of cryogenic tanks are the gores, which are welded together to make the rounded ends of the tanks. The required thicknesses of these gores depend on the specific SLS configuration and may exceed the current experience base in the manufacture of such gores by the stretch forming process. Here we describe the steps taken to enhance the formability of Al-Li 2195 by optimizing the heat treatment and stretch forming processes for gore thicknesses up to 0.75", which envelopes the maximum expected gore thicknesses for SLS tanks. An annealing treatment, developed at Marshall Space Flight Center, increased the forming range and strain hardening exponent of Al-Li 2195 plates. Using this annealing treatment, one 0.525" thick and two 0.75" thick gores were manufactured by the stretch forming process. The annealing treatment enabled the stretch forming of the largest ever cross sectional area (thickness x width) of an Al-Li 2195 plate achieved by the manufacturer. Mechanical testing of the gores showed greater than expected ultimate tensile strength, yield strength, modulus, and elongation values. The gores also exhibited acceptable fracture toughness at room and LN2 temperatures. All of the measured data indicate that the stretch formed gores have sufficient material properties to be used in flight domes.

  16. Corrigendum.

    PubMed

    2017-04-01

    Holden A, Merrilees S, Buckley B, et al. First-in-human experience with the Gore balloon-expandable covered endoprosthesis in iliac artery occlusive disease. J Endovasc Ther. 2017;24:11-18. doi: 10.1177/1526602816680570 .

  17. [Prophylactics and treatment of postoperative hernias of the lateral abdominal walls using polypropylene endoprosthesis].

    PubMed

    Sukovatykh, B S; Valuĭskaia, N M; Pravednikova, N V; Netiaga, A A; Kas'ianova, M A; Zhukovskiĭ, V A

    2011-01-01

    An analysis of complex examination and treatment of 151 patients after planned and performed surgical interventions on organs of the retroperitoneal space was made. The patients were divided into 4 groups. The first group (of comparison) included 46 patients who were treated by lumbotomy for different diseases of organs of the urinary system. In 35 patients of the second group (prophylactics) the indications were determined and in 20 patients preventive endoprosthesis of the lateral abdominal wall using polypropylene endoprosthesis was fulfilled. Herniotomy with plasty of the lateral abdominal wall using local tissues was fulfilled in 30 patients. Prosthesing hernioplasty of the lateral abdominal wall was fulfilled in 40 patients of the main group. It was found that preventive endoprosthesis of the lateral abdominal wall allowed prevention of progressing anatomo-functional i/isufficiency and the appearance of postoperative hernias. The application of polypropylene endoprosthesis for the treatment of postoperative hernias allows obtaining 36.4% more good results as compared with the control group, 21.7% decreased number of satisfactory results and no recurrent hernias.

  18. Truth and opinion in climate change discourse: the Gore-Hansen disagreement.

    PubMed

    Russill, Chris

    2011-11-01

    In this paper, I discuss the "inconvenient truth" strategy of Al Gore. I argue that Gore's notion of truth upholds a conception of science and policy that narrows our understanding of climate change discourse. In one notable exchange, Gore and NASA scientist, James Hansen, disagreed about whether scientific statements based on Hansen's computer simulations were truth or opinion. This exchange is featured in An Inconvenient Truth, yet the disagreement is edited from the film and presented simply as an instance of Hansen speaking "inconvenient truth". In this article, I compare the filmic representation of Hansen's testimony with the congressional record. I place their exchange in a broader historical perspective on climate change disputation in order to discuss the implications of Gore's perspective on truth.

  19. Abrupt transition from fractional crystallization to magma mixing at Gorely volcano (Kamchatka) after caldera collapse

    NASA Astrophysics Data System (ADS)

    Gavrilenko, Maxim; Ozerov, Alexey; Kyle, Philip R.; Carr, Michael J.; Nikulin, Alex; Vidito, Christopher; Danyushevsky, Leonid

    2016-07-01

    A series of large caldera-forming eruptions (361-38 ka) transformed Gorely volcano, southern Kamchatka Peninsula, from a shield-type system dominated by fractional crystallization processes to a composite volcanic center, exhibiting geochemical evidence of magma mixing. Old Gorely, an early shield volcano (700-361 ka), was followed by Young Gorely eruptions. Calc-alkaline high magnesium basalt to rhyolite lavas have been erupted from Gorely volcano since the Pleistocene. Fractional crystallization dominated evolution of the Old Gorely magmas, whereas magma mixing is more prominent in the Young Gorely eruptive products. The role of recharge-evacuation processes in Gorely magma evolution is negligible (a closed magmatic system); however, crustal rock assimilation plays a significant role for the evolved magmas. Most Gorely magmas differentiate in a shallow magmatic system at pressures up to 300 MPa, ˜3 wt% H2O, and oxygen fugacity of ˜QFM + 1.5 log units. Magma temperatures of 1123-1218 °C were measured using aluminum distribution between olivine and spinel in Old and Young Gorely basalts. The crystallization sequence of major minerals for Old Gorely was as follows: olivine and spinel (Ol + Sp) for mafic compositions (more than 5 wt% of MgO); clinopyroxene and plagioclase crystallized at ˜5 wt% of MgO (Ol + Cpx + Plag) and magnetite at ˜3.5 wt% of MgO (Ol + Cpx + Plag + Mt). We show that the shallow magma chamber evolution of Old Gorely occurs under conditions of decompression and degassing. We find that the caldera-forming eruption(s) modified the magma plumbing geometry. This led to a change in the dominant magma evolution process from fractional crystallization to magma mixing. We further suggest that disruption of the magma chamber and accompanying change in differentiation process have the potential to transform a shield volcanic system to that of composite cone on a global scale.

  20. Aluminum 2195 T8 Gore Development for Space Launch System Core and Upper Stage

    NASA Technical Reports Server (NTRS)

    Volz, Martin

    2015-01-01

    Gores are pie-shaped panels that are welded together to form the dome ends of rocket fuel tanks as shown in figure 1. Replacing aluminum alloy 2219 with aluminum (Al)-lithium (Li) alloy 2195 as the Space Launch System (SLS) cryogenic tank material would save enormous amounts of weight. In fact, it has been calculated that simply replacing Al 2219 gores with Al 2195 gores on the SLS core stage domes could save approximately 3,800 pound-mass. This is because the Al-Li 2195 alloy exhibits both higher mechanical properties and lower density than the SLS baseline Al 2219 alloy. Indeed, the known advantages of Al 2195 led to its use as a replacement for Al 2219 in the shuttle external tank program. The required thicknesses of Al 2195 gores for either SLS core stage tanks or upper stage tanks will depend on the specific design configurations. The required thicknesses or widths may exceed the current experience base in the manufacture of such gores by the stretch-forming process. Accordingly, the primary objective of this project was to enhance the formability of Al 2195 by optimizing the heat treatment and stretch-forming process for gore thicknesses up to 0.75 inches, which envelop the maximum expected gore thicknesses for SLS tank configurations.

  1. Percutaneous treatment of delayed post-atherectomy superficial femoral artery pseudoaneurysm.

    PubMed

    Akkus, Nuri Ilker; Fay, Matt; Varma, Jai

    2012-10-01

    SilverHawk atherectomy is commonly used in lower extremity percutaneous interventions. Minor perforations during SilverHawk atherectomy procedures are reported at a range of 0.8%. There are few reported cases in the literature about very late pseuodoaneursym formation after SilverHawk atherectomy. Herein we report a very unusual, late, concealed, acute rupture of superficial femoral artery with a large, painful pseuodoaneursym formation, 1 week after Silver- Hawk atherectomy and its treatment with Viabahn stent graft (W.L. Gore & Associates).

  2. Al Gore attends Fall Meeting session on Earth observing satellite

    NASA Astrophysics Data System (ADS)

    Richman, Barbara T.

    2011-12-01

    Former U.S. vice president Al Gore, making unscheduled remarks at an AGU Fall Meeting session, said, "The reason you see so many pictures" of the Deep Space Climate Observatory (DSCOVR) satellite at this session is "that it already has been built." However, "because one of its primary missions was to help document global warming, it was canceled. So for those who are interested in struggling against political influence," Gore said, "the benefits have been documented well here." Gore made his comments after the third oral presentation at the 8 December session entitled "Earth Observations From the L1 (Lagrangian Point No. 1)," which focused on the capabilities of and progress on refurbishing DSCOVR. The satellite, formerly called Triana, had been proposed by Gore in 1998 to collect climate data. Although Triana was built, it was never launched: Congress mandated that before the satellite could be sent into space the National Academies of Science needed to confirm that the science it would be doing was worthwhile. By the time the scientific validation was complete, the satellite "was no longer compatible with the space shuttle manifest," Robert C. Smith, program manager for strategic integration at the NASA Goddard Space Flight Center, told Eos.

  3. Bidirectional lift of the anterior midcheek with Gore-Tex cable sutures.

    PubMed

    Sasaki, Gordon H; Oberg, Kerby C; Kim, E Yoonah

    2003-01-01

    The reader is presumed to have a broad understanding of the anatomy of the anterior midface. After reading this article, the participant should be able to: Physicians may earn 1 hour of Category 1 CME credit by successfully completing the examination on the basis of material covered in this article. The examination begins on page 257. We have previously described a technique of anterior midface soft tissue repositioning using 2 cable sutures directed only in a superolateral direction. This technique achieves a more normal distribution of subcutaneous fat laterally over the malar bag prominence but does little to overcome central and medial hollowness in the palpebromalar and tear-trough areas. We describe an alteration of our original technique that introduces a vertical lift of the anterior midface soft tissue utilizing Gore-Tex, (W.L. Gore & Associates, Flagstaff, AZ) cable sutures while elevating the preperiosteal soft tissue. We used a transconjunctival approach to expose the postseptal fat, orbital rim, and arcus marginalis. Subperiosteal dissection over the orbital rim was performed to prepare a pocket for the malar fat pads. Using 6.5-cm Keith needles, we placed a braided suture medially, lateral to the location of the infraorbital nerve and foramen, and maneuvered it through the soft tissue until all signs of dimpling at the nasolabial line or upward distortion of the upper lip were removed. A Gore-Tex graft was introduced and seated in a cupped configuration that anchored the caudal fat pad at the nasolabial line. The medial fat pad and vascular pedicle were transposed over the orbital rim into the predissected pocket; the central fat pad was also fashioned into a pedicle and moved into its pocket. The Gore-Tex sutures were tightened, elevating the supraperiosteal soft tissue vertically. A second set of Gore-Tex sutures elevated the anterior midface soft tissue toward the deep temporal fascia. Between 1999 and 2002, 197 patients underwent bidirectional

  4. Bush and Gore Focus on Schools.

    ERIC Educational Resources Information Center

    Joiner, Lottie L.

    2000-01-01

    In the 2000 presidential race, education seems a top priority for Vice-President Al Gore and Texas Governor George W. Bush. Although both candidates are promising billions of federal-aid dollars to raise standards, many believe they are ignoring factors such as student motivation and funding inequities. (MLH)

  5. Gore offers to help drug companies pursue research.

    PubMed

    1996-03-08

    A meeting convened between Vice President Al Gore and executives of leading pharmaceutical companies to determine means of accelerating efforts to develop vaccines, therapeutics, and microbicides for people with HIV. Gore explained that the administration will work with pharmaceutical companies to determine the long-term effectiveness of drugs approved by the Food and Drug Administration (FDA), work with international groups to increase investment in vaccine development, help develop new microbicides for women with HIV, and identify promising areas of AIDS research. According to advocates, the Clinton Administration has made great strides in improving and accelerating the FDA's drug approval process. The next goal of the pharmaceutical research agenda should be to include consumer advocates in the decision-making process.

  6. Gore's Controversial Priorities for Higher Education.

    ERIC Educational Resources Information Center

    Gose, Ben

    2000-01-01

    Evaluates presidential candidate Al Gore's priorities for higher education, noting criticism by some educators of his emphasis on benefits for the middle class and the large number of specific proposals he has offered, including the College Opportunity Tax Cut, 21st Century Teachers' Corps, 401(j) Educational Savings Accounts, the National Tuition…

  7. 77 FR 21722 - Gore Creek Restoration Project; Intent To Prepare an Environmental Impact Statement

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-11

    ... complete previously analyzed vegetation management projects, an analysis of additional temporary roads... DEPARTMENT OF AGRICULTURE Forest Service Gore Creek Restoration Project; Intent To Prepare an Environmental Impact Statement AGENCY: Medicine Bow-Routt National Forests, Forest Service, USDA. Project: Gore...

  8. Consensus on abortion unlikely at U.N. conference, Gore says.

    PubMed

    1994-08-26

    US Vice President Al Gore is pessimistic about the likelihood of consensus on abortion and contraception at the 1994 World Population Conference given opposition on the part of the Vatican, governments of nations with large Roman Catholic populations, and Muslim fundamentalists. Although the Clinton Administration is advocating safe, legal abortion and accessible contraception, it does not intent to push for abortion rights in countries where the procedure is illegal. On the other hand, Gore has expressed confidence that the Cairo conference will forge a new approach to population and development based on improvements in women's status.

  9. Malignant biliary obstruction complicated by ascites: Closure of the transhepatic tract with cyanoacrylate glue after placement of an endoprosthesis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cekirge, Saruhan; Akhan, Okan; Ozmen, Mustafa

    1997-05-15

    A new technique using cyanoacrylate glue is suggested for closing the transparenchymal tract following metallic endoprosthesis placement in a patient with malignant biliary obstruction complicated by ascites. With this technique, complications related to bile reflux through the transparenchymal tract would be avoided after transhepatic endoprosthesis placement in patients who have ascites. This technique would also be useful for avoiding bleeding following transhepatic portal venous puncture.

  10. Election 2000: The Keys Point to Gore.

    ERIC Educational Resources Information Center

    Lichtman, Allan J.

    2000-01-01

    Asserts that Vice President Al Gore will be elected in 2000 based on the performance of the Clinton administration. Utilizes the key to the White House, 13 true-or-false diagnostic questions stated as propositions. If five or less are false then the party in power wins. (CMK)

  11. Room temperature stretch forming of scale space shuttle external tank dome gores. Volume 1: Technical

    NASA Technical Reports Server (NTRS)

    Blunck, R. D.; Krantz, D. E.

    1974-01-01

    An account of activities and data gathered in the Room Temperature Stretch Forming of One-third Scale External Tank Bulkhead Gores for space shuttle study, and a tooling design and production cost study are reported. The following study phases are described: (1) the stretch forming of three approximately one-third scale external tank dome gores from single sheets of 2219-T37 aluminum alloy; (2) the designing of a full scale production die, including a determination of tooling requirements; and (3) the determination of cost per gore at the required production rates, including manufacturing, packaging, and shipping.

  12. Magma mixing and degassing processes in the magma chamber of Gorely volcano (Kamchatka): evidence from whole-rock and olivine chemistry.

    NASA Astrophysics Data System (ADS)

    Gavrilenko, M.; Ozerov, A.; Kyle, P. R.; Carr, M. J.; Nikulin, A.

    2015-12-01

    Gorely is a shield-type volcano in southern Kamchatka currently in an eruptive phase [1] with prior eruptions recorded in 1980 and 1984 [4]. It is comprised of three main structural units: ancient (middle Pleistocene) edifice called 'Old-Gorely' volcano; thick ignimbrite complex, associated with a caldera forming eruption (40 ka); modern edifice named 'Young Gorely' growing inside the caldera [6]. Gorely lavas consist of a suite of compositions ranging from basalt to rhyolite (calk-alkaline series).In this study we describe the mixing processes in magma chamber [2] based on analysis of whole-rock and mineralogical data in an attempt to compare the magma evolution pathways for 'Old Gorely' and Young Gorely volcanoes. Our results indicate that fractional crystallization (FC) is the dominant process for 'Old Gorely' magmas, while 'Young Gorely' magmas are the result of mixing of primitive and evolved magmas in Gorely magma chamber], which is located at depth range from 2 to 10 km below the volcano edifice [6]. We present results of olivine high-precision electron microprobe data analysis (20kV, 300 nA) [7], alongside traditional methods (WR diagrams, mineral zonation) to demonstrate the difference between 'Old' (FC) and 'Young' (mixing) Gorely magmas. We estimated magma H2O (~3 wt.%) content for Gorely magma using independent methods: 1) using THI [8]; 2) using ΔT Ol-Pl [3]; 3) using Ol-Sp temperatures [9]. Additionally, calculations of [4] and analysis of olivine chemistry allow us to describe water content changes during magma evolution. We show that degassing (H2O removal) is necessary for strong plagioclase fractionation, which is observed in Gorely evolved lavas (less than 5 wt.% of MgO). [1] Aiuppa et al. (2012), GRL. 39(6): p.L06307. [2] Gorbach & Portnyagin (2011) Petrology, 19(2): p.134-166. [3] Danyushevsky (2001) JVGR, 110(3-4): p.265-280. [4] Kirsanov & Melekescev (1991) Active volcanoes of Kamchatka, v.2: p.294-317. [5] Mironov & Portnyagin (2011

  13. Low-flow water-quality characterization of the Gore Creek watershed, upper Colorado River basin, Colorado, August 1996

    USGS Publications Warehouse

    Wynn, Kirby H.; Spahr, Norman E.

    1998-01-01

    The Upper Colorado River Basin (UCOL) is one of 59 National Water-Quality Assessment (NAWQA) study units designed to assess the status and trends of the Nation?s water quality (Leahy and others, 1990). The UCOL study unit began operation in 1994, and surface-water-quality data collection at a network of 14 sites began in October 1995 (Apodaca and others, 1996; Spahr and others, 1996). Gore Creek, which flows through Vail, Colorado, originates in pristine alpine headwaters and is designated a gold-medal trout fishery. The creek drains an area of about 102 square miles and is a tributary to the Eagle River. Gore Creek at the mouth near Minturn (site 13 in fig. 1) is one of the 14 sites in the UCOL network. This site was selected to evaluate water quality resulting from urban development and recreational land use. The Gore Creek watershed has undergone rapid land-use changes since the 1960?s as the Vail area shifted from traditional mountain ranchlands to a four-season resort community. Residential, recreational, commercial, and transportation development continues near Gore Creek and its tributaries to support the increasing permanent and tourist population of the area. Interstate 70 runs through the watershed from Vail Pass near site 14, along the eastern side of Black Gore Creek, and along the northern side of the main stem of Gore Creek to the mouth of the watershed (fig. 1). A major local concern is how increasing urbanization/recreation affects the water quality, gold-medal trout fishery, and aesthetic values of Gore Creek. An evaluation of the spatial characteristics of water quality in the watershed upstream from site 13 at the mouth of Gore Creek (fig. 1) can provide local water and land managers with information necessary to establish water policy and make land-use planning decisions to maintain or improve water quality. Historical data collected at the mouth of Gore Creek provide information about water quality resulting from land use, but a synoptic

  14. Mutnovsky and Gorely Volcanoes, Kamchatka as Planetary Analogue Sites

    NASA Astrophysics Data System (ADS)

    Evdokimova, N.; Izbekov, P. E.; Krupskaya, V.; Muratov, A.

    2016-12-01

    Recent advances in Mars studies suggest that volcanic rocks, which dominated Martian surface in the past, have been exposed to alteration processes in a water-bearing environment during Noachian, before 3.7 Gy. Active volcanoes on Earth are natural laboratories, where volcanic processes and their associated products can be studied directly. This is particularly important for studying of alteration of juvenile volcanic products in aqueous environment because of the transient nature of some of the alteration products, as well as the environment itself. Terrestrial analogues help us to better understand processes on Mars; they are particularly useful as a test sites for preparation to future Mars missions. In this presentation we describe planetary analogue sites at Mutnovsky and Gorely Volcanoes in Kamchatka, which might be helpful for comparative studies and preparation to future Mars missions. Mutnovsky and Gorely Volcanoes are located 75 km south of Petropavlovsk-Kamchatsky, in the southern part of the Kamchatka Peninsula, Russia. The modern volcanic landscape in the area was shaped in Holocene (recent 10,000 years) through intermittent eruption of magmas ranging in composition from basalts to dacites and rhyodacites, with basaltic andesite lavas dominating in the modern relief. Two localities could be of a particular interest: (1) Mutnovsky NW thermal field featuring processes of active hydrothermal alteration of lavas of basaltic andesite and (2) dry lake at the bottom of Gorely caldera featuring products of mechanical disintegration of basaltic andesite lavas by eolian processes with short seasonal sedimentation in aqueous environment.

  15. EVAR using the Nellix Sac-anchoring endoprosthesis: treatment of favourable and adverse anatomy.

    PubMed

    Krievins, D K; Holden, A; Savlovskis, J; Calderas, C; Donayre, C E; Moll, F L; Katzen, B; Zarins, C K

    2011-07-01

    The study aimed to review the results of endovascular aneurysm repair (EVAR) using a novel sac-anchoring endoprosthesis in patients with favourable and adverse anatomy. This is a prospective, multicentre, clinical trial. The Nellix endoprosthesis consists of dual, balloon-expandable endoframes, surrounded by polymer-filled endobags, which obliterate the aneurysm sac and maintain endograft position. The study reviewed worldwide clinical experience and Core Lab evaluation of computed tomography (CT) scans. From 2008 to 2010, 34 patients (age 71 ± 8 years, abdominal aortic aneurysm (AAA) diameter 5.8 ± 0.8 cm) were treated at four clinical sites. Seventeen patients (50%) met the inclusion criteria for Food and Drug Administration (FDA)-approved endografts (favourable anatomy); 17 (50%) had one or more adverse anatomic feature: neck length <10 mm (24%), neck angle >60° (9%) and iliac diameter >23 mm (38%). Device deployment was successful in all patients; iliac aneurysm treatment preserved hypogastric patency. Perioperative mortality was 1/34 (2.9%); one patient died at 10 months of congestive heart failure (CHF); one patient had a secondary procedure at 15 months. During 15 ± 6 months follow-up, there were no differences in outcome between favourable and adverse anatomy patients. Follow-up CT extending up to 2 years revealed no change in aneurysm size or endograft position and no new endoleaks. Favourable and adverse anatomy patients can be successfully treated using the Nellix sac-anchoring endoprosthesis. Early results are promising but longer-term studies are needed. Copyright © 2011 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  16. Sustained Benefit at 2 Years for Covered Stents Versus Bare-Metal Stents in Long SFA Lesions: The VIASTAR Trial

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lammer, Johannes, E-mail: jlammer@gmx.at, E-mail: johannes.lammer@meduniwien.ac.at; Zeller, Thomas, E-mail: thomas.zeller@universitaets-herzzentrum.de; Hausegger, Klaus A., E-mail: klaus.hausegger@lkh-klu.at

    PurposeThe hypothesis that covered stents are superior to bare-metal stents (BMS) in long femoropopliteal artery disease was tested. The one-year results of the VIASTAR trial revealed a patency benefit of covered stents in the treatment-per-protocol (TPP) analysis only.MethodsA prospective, randomized, single-blind, multicenter study evaluated 141 patients with symptomatic peripheral arterial disease (PAD) after treatment with heparin-bonded covered stents (VIABAHN{sup ®} Endoprosthesis) or BMS. Clinical outcomes and patency rates were assessed at 1, 6, 12, and 24 months. Mean lesion length was 19.0 ± 6.3 cm in the VIABAHN{sup ®} versus 17.3 ± 6.6 cm in the BMS group.ResultsThe 24-month primary patency rates in the VIABAHN{sup ®} andmore » BMS group were: intention-to-treat 63.1 (95 % CI 0.52–0.76) versus 41.2 % (95 % CI 0.29–0.57; log rank p = 0.04) and TPP 69.4 (95 % CI 0.58–0.83) versus 40.0 % (95 % CI 0.28–0.56; log rank p = 0.004). Freedom from target-lesion-revascularization (TLR) was 79.4 (95 % CI 0.70–0.90) versus 73.0 % (95 % CI 0.63–0.85) for VIABAHN{sup ®} versus BMS (log rank p = 0.37). For the TPP group in lesions ≥20 cm, the 24-month patency rates were 65.2 (95 % CI 0.50–0.85) versus 26.7 % (95 % CI 0.12–0.59; log rank p = 0.004) for VIABAHN{sup ®} versus BMS, and freedom from TLR was 80.0 (95 % CI 0.68–0.94) versus 61.9 % (95 % CI 0.44–0.87; log rank p = 0.13). The ankle brachial index was 0.89 ± 0.18 versus 0.91 ± 0.17 (p = 0.76) at 24-month in the VIABAHN{sup ®} versus the BMS group, respectively.ConclusionAt 24-month, this trial in PAD patients with long femoropopliteal lesions demonstrated a significantly improved primary patency rate for heparin-bonded covered stents compared to BMS, however, without a significant impact on clinical outcomes and TLR rate (Reg. Nr. ISRCTN48164244)« less

  17. Draw forming of scale shuttle external tank dome gores

    NASA Technical Reports Server (NTRS)

    Garfield, G.

    1974-01-01

    The process for manufacturing external tank dome gores is discussed. The test fixture and test procedure are described. The characteristics of the draw forming die are analyzed. The specific subjects included are: (1) forming, (2) trimming, (3) cleaning, and (4) heat treatment.

  18. A novel approach in managing right-sided haemothorax in neurofibromatosis type 1.

    PubMed

    Mydin, Muhammad Izanee Mohamed; Sharma, Amit; Zia, Zergham; Hawari, Mohammad; Jadoon, Mehmood; Majewski, Andrzej

    2015-06-01

    Spontaneous haemothorax due to vasculopathy in patients with neurofibromatosis type 1 is rare but life-threatening. A 56-year-old lady with neurofibromatosis type 1 presented with right-sided chest pain, dyspnoea, and collapse. Computed tomography showed a right-sided hemothorax. Urgent angiography showed contrast leakage from a right subclavian artery pseudoaneurysm. A Gore Viabahn endovascular stent graft was deployed. Completion angiography revealed satisfactory haemostasis. She underwent video-assisted thoracoscopic evacuation of the hemothorax, with good results. This case highlights a novel approach to managing a rare emergency, using combined procedures. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  19. The UNO Aviation Monograph Series: Aviation Security: An Annotated Bibliography of Responses to the Gore Commission

    NASA Technical Reports Server (NTRS)

    Carrico, John S.; Schaaf, Michaela M.

    1998-01-01

    This monograph is a companion to UNOAI Monograph 96-2, "The Image of Airport Security: An Annotated Bibliography," compiled in June 1996. The White House Commission on Aviation Safety and Security, headed by Vice President Al Gore, was formed as a result of the TWA Flight 800 crash in August 1996. The Commission's final report included 31 recommendations addressed toward aviation security. The recommendations were cause for security issues to be revisited in the media and by the aviation industry. These developments necessitated the need for an updated bibliography to review the resulting literature. Many of the articles were written in response to the recommendations made by the Gore Commission. "Aviation Security: An Annotated Bibliography of Responses to the Gore Commission" is the result of this need.

  20. Identification of the Cause of the Stem Neck Fracture in the Hip Joint Endoprosthesis

    NASA Astrophysics Data System (ADS)

    Ryniewicz, A. M.; Bojko, Ł.; Ryniewicz, A.; Pałka, P.; Ryniewicz, W.

    2018-02-01

    Endoprosthesis stem fractures are among the rarest complications that occur after hip joint arthroplasty. The aim of this paper is to evaluate the causes of the fractures of the Aura II stem neck, which is an element of an endoprosthesis implanted in a patient. In order to achieve it, a radiogram was evaluated, the FEM analysis was carried out for the hip joint replaced using the Aura II prosthesis and scanning tests as well as a chemical analysis were performed for the focus of fatigue. The tests performed indicate that the most probable causes leading to the fatigue fracture of the Aura II stem under examination were material defects in the process of casting and forging (forging the material with delamination and the presence of brittle oxides and carbides) that resulted in a significant reduction of strength and resistance to corrosion. In the light of an unprecedented stem neck fracture, this information should be an indication for non-destructive tests of ready-made stems aiming to discover the material and technological defects that may arise in the process of casting and drop forging.

  1. Multiscale methods for gore curvature calculations from FSI modeling of spacecraft parachutes

    NASA Astrophysics Data System (ADS)

    Takizawa, Kenji; Tezduyar, Tayfun E.; Kolesar, Ryan; Boswell, Cody; Kanai, Taro; Montel, Kenneth

    2014-12-01

    There are now some sophisticated and powerful methods for computer modeling of parachutes. These methods are capable of addressing some of the most formidable computational challenges encountered in parachute modeling, including fluid-structure interaction (FSI) between the parachute and air flow, design complexities such as those seen in spacecraft parachutes, and operational complexities such as use in clusters and disreefing. One should be able to extract from a reliable full-scale parachute modeling any data or analysis needed. In some cases, however, the parachute engineers may want to perform quickly an extended or repetitive analysis with methods based on simplified models. Some of the data needed by a simplified model can very effectively be extracted from a full-scale computer modeling that serves as a pilot. A good example of such data is the circumferential curvature of a parachute gore, where a gore is the slice of the parachute canopy between two radial reinforcement cables running from the parachute vent to the skirt. We present the multiscale methods we devised for gore curvature calculation from FSI modeling of spacecraft parachutes. The methods include those based on the multiscale sequentially-coupled FSI technique and using NURBS meshes. We show how the methods work for the fully-open and two reefed stages of the Orion spacecraft main and drogue parachutes.

  2. Gore Creek watershed, Colorado : assessment of historical and current water quantity, water quality, and aquatic ecology, 1968-98

    USGS Publications Warehouse

    Wynn, Kirby H.; Bauch, Nancy J.; Driver, Nancy E.

    2001-01-01

    The historical and current (1998) water-quantity, water-quality, and aquatic-ecology conditions in the Gore Creek watershed are described as part of a study by the U.S. Geological Survey, done in cooperation with the Town of Vail, the Eagle River Water and Sanitation District, and the Upper Eagle Regional Water Authority. Interpretation of the available water-quantity, water-quality, and aquatic-ecology data collected by various agencies since 1968 showed that background geology and land use in the watershed influence the water quality and stream biota. Surface-water nutrient concentrations generally increased as water moved downstream through the Town of Vail, but concentrations at the mouth of Gore Creek were typical when compared with national data for urban/undeveloped sites. Nitrate concentrations in Gore Creek were highest just downstream from a wastewater-treatment plant discharge, but concentrations decreased at sites farther downstream because of dilution and nitrogen uptake by algae. Recent total phosphorus concentrations were somewhat elevated when compared to the U.S. Environmental Protection Agency recommended level of 0.10 milligram per liter for control of eutrophication in flowing water. However, total phosphorus concentrations at the mouth of Gore Creek were relatively low when compared to a national study of phosphorus in urban land-use areas. Historically, suspended sediment associated with construction of Interstate 70 in the early 1970's has been of primary concern; however, recent data indicate that streambed aggradation of sediment originating from Interstate 70 traction sanding currently is a greater concern. About 4,000 tons of coarse sand and fine gravel is washed into Black Gore Creek each year following application of traction materials to Interstate 70 during adverse winter driving conditions. Suspended-sediment concentrations were low in Black Gore Creek; however, bedload-transport rates of as much as 4 tons per day have been measured

  3. [Treatment of postoperative abdominal hernias with polypropylene endoprosthesis].

    PubMed

    Chakhvadze, B Iu; Nakashidze, D Kh

    2009-06-01

    The results of the surgical treatment of 82 patients with postoperative abdominal hernias were analysed. All of the patients underwent surgery with polypropylene endoprosthesis. The choice of a hernioplasty method depended on relative volume of postoperative hernia. Middle-sized hernias were indications for reconstructive surgery (complete adaptation of muscular and aponeurotic layers was maintained). The large and gigantic hernias were indications for correcting surgery (specified diastasis of muscular and aponeurotic layers was maintained). In case of lacking of peritoneum (30 patients) greater omentum was used for isolation of the net from intestinal loops. It is concluded that greater omentum provides good extraperitonisation of transplant from intestinal loop and prevents complications due to contact of net with abdominal organs. Postoperative complications mainly were local and seen in 29% cases. There were no lethal outcomes.

  4. A novel combined hemipelvic endoprosthesis for peri-acetabular tumours involving sacroiliac joint: a finite element study.

    PubMed

    Wang, Bo; Sun, Peidong; Xie, Xianbiao; Wu, Weidong; Tu, Jian; Ouyang, Jun; Shen, Jingnan

    2015-11-01

    Our aim was to introduce a novel combined hemipelvic endoprosthesis for pelvic reconstruction after Enneking type I/II/IV resection and to evaluate the biomechanical properties of the endoprosthesis using finite element analysis. A three-dimensional finite element model of the postoperative pelvis was developed based on computed tomography (CT) images of the patient with the best post-operative limb function. A force of 400 N was applied along the longitudinal axis of the normal and post-operative pelvis for two positions: standing on two feet and sitting. Stress-distribution analysis was performed in both positions, and results were compared. Prosthesis improvements were simulated by intervertebral fusion and extra screw fixation. In the normal pelvis, stress distributions were mostly concentrated on the superior area of the acetabulum, arcuate line, sacroiliac joint and sacral midline in both static conditions, and peak stresses of 1.52 MPa and 4.53 MPa were observed at the superior area of the greater sciatic notch and ischial tuberosity, respectively. For the reconstructed hemipelvis, stress distributions were concentrated on the connecting rods of the acetabular component and the proximal segment of the pedicle rods, and peak stresses of 252 MPa and 213 MPa were observed on the proximal pedicle rods of the fourth lumbar vertebra for standing and sitting, respectively. Interbody fusion of the fourth and fifth lumbar vertebrae and extra screw fixation to the sacrum decreased the peak stresses by 33.0 % and 18.3 % while standing and by 10.8 % and 6.6 % while sitting. Reconstruction with combined hemipelvic endoprosthesis after types I/II/IV resection of the pelvis fulfilled physiological and biomechanical demands of the hemipelvis and yielded good biomechanical characteristics.

  5. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT--BAGHOUSE FILTRATION PRODUCTS, W.L. GORE ASSOC., INC.

    EPA Science Inventory

    The U.S. Environmental Protection Agency Air Pollution Control Technology (APCT) Verification Center evaluates the performance of baghouse filtration products used primarily to control PM2.5 emissions. This verification statement summarizes the test results for W.L. Gore & Assoc....

  6. [Joint endoprosthesis pathology. Histopathological diagnostics and classification].

    PubMed

    Krenn, V; Morawietz, L; Jakobs, M; Kienapfel, H; Ascherl, R; Bause, L; Kuhn, H; Matziolis, G; Skutek, M; Gehrke, T

    2011-05-01

    Prosthesis durability has steadily increased with high 10-year rates of 88-95%. However, four pathogenetic groups of diseases can decrease prosthesis durability: (1) periprosthetic wear particle disease (aseptic loosening) (2) bacterial infection (septic loosening) (3) periprosthetic ossification, and (4) arthrofibrosis. The histopathological "extended consensus classification of periprosthetic membranes" includes four types of membranes, arthrofibrosis, and osseous diseases of endoprosthetics: The four types of neosynovia are: wear particle-induced type (type I), mean prosthesis durability (MPD) in years 12.0; infectious type (type II), MPD 2.5; combined type (type III) MPD 4.2; and indeterminate type (type IV), MPD 5.5. Arthrofibrosis can be determined in three grades: grade 1 needs clinical information to be differentiated from a type IV membrane, and grades 2 & 3 can be diagnosed histopathologically. Periprosthetic ossification, osteopenia-induced fractures, and aseptic osteonecrosis can be histopathologically diagnosed safely with clinical information. The extended consensus classification of periprosthetic membranes may be a diagnostic groundwork for a future national endoprosthesis register.

  7. Initial clinical experience with a sac-anchoring endoprosthesis for aortic aneurysm repair.

    PubMed

    Donayre, Carlos E; Zarins, Christopher K; Krievins, Dainis K; Holden, Andrew; Hill, Andrew; Calderas, Carlos; Velez, Jaime; White, Rodney A

    2011-03-01

    All current aortic endografts depend on proximal and distal fixation to prevent migration. However, migration and rupture can occur, particularly in patients with aortic necks that are short or angulated, or both. We present our initial clinical experience with a new sac-anchoring endoprosthesis designed to anchor and seal the device within the aneurysm sac. The initial worldwide experience using a new endoprosthesis for the treatment of aortic aneurysms (Nellix Endovascular, Palo Alto, Calif) was reviewed. The endoprosthesis consists of dual balloon-expandable endoframes surrounded by polymer-filled endobags designed to obliterate the aneurysm sac and maintain endograft position. Clinical results and follow-up contrast computed tomography (CT) scans at 30 days and 6 and 12 months were reviewed. The endograft was successfully deployed in 21 patients with infrarenal aortic aneurysms measuring 5.7 ± 0.7 cm (range, 4.3-7.4 cm). Two patients with common iliac aneurysms were treated with sac-anchoring extenders that maintained patency of the internal iliac artery. Infusion of 71 ± 37 mL of polymer (range, 19-158 mL) into the aortic endobags resulted in complete aneurysm exclusion in all patients. Mean implant time was 76 ± 35 minutes, with 33 ± 17 minutes of fluoroscopy time and 180 ± 81 mL of contrast; estimated blood loss was 174 ± 116 mL. One patient died during the postoperative period (30-day mortality, 4.8%), and one died at 10 months from non-device-related causes. During a mean follow-up of 8.7 ± 3.1 months and a median of 6.3 months, there were no late aneurysm- or device-related adverse events and no secondary procedures. CT imaging studies at 6 months and 1 year revealed no increase in aneurysm size, no device migration, and no new endoleaks. One patient had a limited proximal type I endoleak at 30 days that resolved at 60 days and remained sealed. One patient has an ongoing distal type I endoleak near the iliac bifurcation, with no change in aneurysm

  8. Treatment of malignant biliary obstruction by endoscopic implantation of iridium 192 using a new double lumen endoprosthesis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Siegel, J.H.; Lichtenstein, J.L.; Pullano, W.E.

    1988-07-01

    Iridium 192 seeds contained in a ribbon were preloaded into a new double lumen 11 Fr endoprosthesis which was then inserted into malignant strictures of the bile duct and ampulla and left in place for 48 hours until 5000 rads were delivered to the tumor. The procedure was carried out in 14 patients (7 women, 7 men; mean age, 63.2 years; range, 46 to 86 years). Six patients were treated for cholangiocarcinomas, four with pancreatic carcinomas, and four with ampullary carcinomas. No complications occurred. The mean survival of the group was 7 months (range, 3 days to 27 months). Thismore » new technique provides both intraluminal brachytherapy and biliary drainage and is inserted intraduodenally across the papilla of Vater avoiding puncture of the liver and external hardware required by the percutaneous technique and hardware necessitated with a nasobiliary tube. Following removal of the iridium prosthesis, a large caliber endoprosthesis is inserted for continued decompression. Because of proven efficacy of endoprostheses, this new technique should be considered when intraluminal irradiation is indicated.« less

  9. Seismic structures beneath Popocatepetl (Mexico) and Gorely (Kamchatka) volcanoes derived from passive tomography studies

    NASA Astrophysics Data System (ADS)

    Kuznetsov, Pavel; Koulakov, Ivan

    2014-05-01

    A number of active volcanoes are observed in different parts of the world, and they attract great interest of scientists. Comparing their characteristics helps in understanding the origin and mechanisms of their activity. One of the most effective methods for studying the deep structure beneath volcanoes is passive source seismic tomography. In this study we present results of tomographic inversions for two active volcanoes located in different parts of the world: Popocatepetl (Mexico) and Gorely (Kamchatka, Russia). In the past century both volcanoes were actively erupted that explains great interest to their detailed investigations. In both cases we made the full data analysis starting from picking the arrival times from local events. In the case of the Popocatepetl study, a temporary seismological network was deployed by GFZ for the period from December 1999 to July 2000. Note that during this period there were a very few events recorded inside the volcano. Most of recorded earthquakes occurred in surrounding areas and they probably have the tectonic nature. We performed a special analysis to ground the efficiency of using these data for studying seismic structure beneath the network installed on the volcano. The tomographic inversion was performed using the LOTOS code by Koulakov (2009). Beneath the Popocatepetl volcano we have found a zone of strong anti-correlation between P- and S-velocities that leaded to high values of Vp/Vs ratio. Similar features were found for some other volcanoes in previous studies. We interpret these anomalies as zones of high content of fluids and melts that are related to active magma sources. For the case of Gorely volcano we used the data of a temporary network just deployed in summer 2013 by our team from IPGG, Novosibirsk. Luckily, during the field works, the volcano started to manifest strong seismic activity. In this period, 100 - 200 volcanic events occurred daily. We collected the continuous seismic records from 20 stations

  10. Computer-aided resection and endoprosthesis design for the management of malignant bone tumors around the knee: outcomes of 12 cases.

    PubMed

    Ding, Huan-wen; Yu, Guang-wen; Tu, Qiang; Liu, Bao; Shen, Jian-jian; Wang, Hong; Wang, Ying-jun

    2013-11-22

    To report the outcomes of computer-aided resection and endoprosthesis design for the management of malignant bone tumors around the knee. Computed tomography (CT) and magnetic resonance imaging (MRI) data were input into computer software to produce three-dimensional (3D) models of the tumor extent. Imaging data was then used to create a template for surgical resection, and development of an individualized combined allogeneic bone/endoprosthesis. Surgical simulations were performed prior to the actual surgery. This study included 9 males and 3 females with a mean age of 25.3 years (range, 13 to 40 years). There were 9 tumors in the distal femur and 3 in the proximal tibia. There were no surgical complications. In all cases pathologically confirmed clear surgical margins were obtained. Postoperative radiographs showed the range of tumor resection was in accordance with the preoperative design, and the morphological reconstruction of the bone defect was satisfactory with complete bilateral symmetry. The mean follow-up time was 26.5 months. Two patients died of their disease and the remaining are alive and well without evidence of recurrence. All patients are able to ambulate freely without restrictions. At the last follow-up, the average International Society of Limb Salvage score was 25.8 (range, 18 to 27), and was excellent in 8 cases and good in 4 cases. Computer-aided design and modeling for the surgical management of bone tumors and subsequent limb reconstruction provides accurate tumor removal with the salvage of a maximal amount of unaffected bone and precise endoprosthesis reconstruction.

  11. An automatic gore panel mapping system

    NASA Technical Reports Server (NTRS)

    Shiver, John D.; Phelps, Norman N.

    1990-01-01

    The Automatic Gore Mapping System is being developed to reduce the time and labor costs associated with manufacturing the External Tank. The present chem-milling processes and procedures are discussed. The down loading of the simulation of the system has to be performed to verify that the simulation package will translate the simulation code into robot code. Also a simulation of this system has to be programmed for a gantry robot instead of the articulating robot that is presently in the system. It was discovered using the simulation package that the articulation robot cannot reach all the point on some of the panels, therefore when the system is ready for production, a gantry robot will be used. Also a hydrosensor system is being developed to replace the point-to-point contact probe. The hydrosensor will allow the robot to perform a non-contact continuous scan of the panel. It will also provide a faster scan of the panel because it will eliminate the in-and-out movement required for the present end effector. The system software is currently being modified so that the hydrosensor will work with the system. The hydrosensor consists of a Krautkramer-Branson transducer encased in a plexiglass nozzle. The water stream pumped through the nozzle is the couplant for the probe. Also, software is being written so that the robot will have the ability to draw the contour lines on the panel displaying the out-of-tolerance regions. Presently the contour lines can only be displayed on the computer screens. Research is also being performed on improving and automating the method of scribing the panels. Presently the panels are manually scribed with a sharp knife. The use of a low power laser or water jet is being studied as a method of scribing the panels. The contour drawing pen will be replaced with scribing tool and the robot will then move along the contour lines. With these developments the Automatic Gore Mapping Systems will provide a reduction in time and labor costs

  12. George W. Bush at Goree Island: American Slavery and the Rhetoric of Redemption

    ERIC Educational Resources Information Center

    Medhurst, Martin J.

    2010-01-01

    On July 8, 2003, at Goree Island, Senegal, George W. Bush delivered the most important speech on American slavery since Abraham Lincoln. As an example of rhetorical artistry, the speech is a masterpiece, putting the brutality of slavery into historical, political, and theological perspective. Although the speech had deliberative effects--it grew…

  13. Hiatal hernia repair with gore bio-a tissue reinforcement: our experience.

    PubMed

    Antonino, Agrusa; Giorgio, Romano; Giuseppe, Frazzetta; Giovanni, De Vita; Silvia, Di Giovanni; Daniela, Chianetta; Giuseppe, Di Buono; Vincenzo, Sorce; Gaspare, Gulotta

    2014-01-01

    Type I hiatal hernia is associated with gastroesophageal reflux disease (GERD) in 50-90% of cases. Several trials strongly support surgery as an effective alternative to medical therapy. Today, laparoscopic fundoplication is considered as the procedure of choice. However, primary laparoscopic hiatal hernia repair is associated with upto 42% recurrence rate. Mesh reinforcement of the crural closure decreases the recurrence but can lead to complications, above all nonabsorbable ones. We experiment a new totally absorbable mesh by Gore. Case. We present a case of a 65-year-old female patient with a 6-year classic history of GERD. Endoscopy revealed a large hiatal hernia and esophagitis. pH study was positive for acid reflux; esophageal manometry revealed LES intrathoracic dislocation. With laparoscopic approach, the hiatal hernia defect was identified and primarily repaired, by crural closure. Gore Bio-A Tissue Reinforcement was trimmed to fit the defect accommodating the esophagus. Nissen fundoplication was performed. Result. Bio-A mesh was easily placed laparoscopically. It has good handling and could be cut and tailored intraoperatively for optimal adaptation. There were no short-term complications. Conclusion. Crural closure reinforcement can be done readily with this new totally absorbable mesh replaced by soft tissue over six months. However, further data and studies are needed to evaluate long-term outcomes.

  14. Pericardial tissue valves and Gore-Tex conduits as an alternative for right ventricular outflow tract replacement in children.

    PubMed

    Allen, Bradley S; El-Zein, Chawki; Cuneo, Betina; Cava, Joseph P; Barth, Mary Jane; Ilbawi, Michel N

    2002-09-01

    There is still no perfect conduit for reconstruction of the right ventricular outflow tract (RVOT) in children. Homografts are not always available in the appropriate size, and degenerate in a few years. This study evaluates the pericardial valve with Gore-Tex conduit as an alternative for RVOT construction. From January 1, 1993, to September 30, 1999, a pericardial tissue valve was inserted in all patients undergoing RVOT reconstruction or pulmonary valve replacement (PVR) who were large enough to accommodate a tissue valve. In patients without a native main pulmonary artery, a new technique was used to construct an RV-PA conduit out of a flat sheet of Gore-Tex, as Dacron frequently leads to stenosis. Data were collected by retrospective review, follow-up echocardiograms, and assessment by a single cardiologist. There were 48 patients, 22 undergoing a PVR alone and 26 a RV-PA valved Gore-Tex conduit. Diagnosis included tetralogy of Fallot (n = 25); truncus arteriosis (n = 9); ventricular septal defect with PA (n = 5); DORV (n = 4); D-TGA with PS (n = 2); and 1 each IAA with sub AS, VSD with PI, and PS s/p Ross procedure. Patient age ranged from 3 to 33 years and 98% were reoperations. The valve sizes ranged from 19 to 33 mm and the median hospital length of stay was 4 days. There were 2 (4.2%) perioperative and 1 (2.1%) late deaths, none related to the valve or Gore-Tex conduit. At a follow-up of 15 to 86 months (mean 43 +/- 16 months), all remaining 45 patients are New York Heart Association class I, all valves are functional, and no patient has required valve or conduit replacement or revision; more importantly, echocardiogram revealed no significant valve or conduit stenosis (mean gradient 16 +/- 8 mm Hg) and no evidence of regurgitation or structural degeneration. A pericardial tissue valve and Gore-Tex conduit provides a reliable alternative for RVOT reconstruction in pediatric patients. It is readily available, molds in the limited retrosternal space, and

  15. Feasibility and safety of a new generation of gore septal occluder device in children.

    PubMed

    Lombardi, Maristella; Tagliente, Maria R; Pirolo, Teodoro; Massari, Elena; Milella, Leonardo; Vairo, Ugo

    2016-12-01

    Transcatheter closure of an ostium secundum atrial septal defect (ASD) is now considered the standard care for most of children with the appropriate anatomy, and is a relatively well-tolerated procedure to reduce the clinical sequelae of ASD, with a low complication rate. The present case reports describe our clinical experience of the percutaneous closure of a secundum ASD in 10 children between December 2011 and November 2012, by means of a new generation of device, the GORE Septal Occluder device. The implantation was successful in all except two cases, the device being properly placed and deployed without malposition or embolization in the catheterization laboratory. No complications were related to the procedure. The successful implant was confirmed and no major adverse events were documented in the following 3-12 months. The new GORE Septal Occluder device appears to be a feasible, well-tolerated and successful tool for the closure of an ASD of 15 mm or less in childhood.

  16. Bradley vs. Gore: how media covered proposals for health insurance reform in the context of the 2000 presidential campaign.

    PubMed

    Mebane, Felicia

    2003-01-01

    This study examines how often national media reported key aspects of Senator Bill Bradley's and Vice President Al Gore's proposals for health insurance reform during the 2000 Democratic primary campaign. The results show that news media reported on Bradley's plan and major features of his plan significantly more often than Gore's. Additionally, few reports contained explicit comparisons that explained which plan would have covered more people or cost more. Public health and media professionals need to work together to improve the quality of information the public depends on to develop views about and support for the uninsured.

  17. [Self-expandable metallic biliary endoprosthesis in malignant obstructive jaundice].

    PubMed

    Güitrón-Cantú, Alfredo; Adalid-Martínez, Raúl; Gutiérrez-Bermúdez, José A

    2005-01-01

    Implantation of metallic stents for malignant biliary strictures has been recognized to be effective alternatives. To show our experience in metallic stents for palliation of malignant biliary strictures. Seventy three patients (38 males, 35 females, mean age 64.26) with malignant biliary strictures have been treated by implantation of metallic stents. Causes of obstruction were pancreatic carcinoma (23/73, 31.5%), bile duct carcinoma (31/73, 42.5%), carcinoma of ampula of Vater (11/73, 15%) and Klatskin tumor (3/73, 4.1%). Endoscopic procedure was successful in all cases. Neither procedure-related morbidity nor mortality was observed. Life surviving curve was 9 months and showed significant difference (p < 0.0071) in patients with carcinoma of ampula of Vater. Self-expanding metal endoprosthesis is a recognized method of palliation in malignant biliary obstruction. It efficiently relieves jaundice and generally improves comfort and nutritional status during the patient's remaining lifetime. The metallic stents are advantageous in patients surviving 6 months or less.

  18. Hiatal Hernia Repair with Gore Bio-A Tissue Reinforcement: Our Experience

    PubMed Central

    Antonino, Agrusa; Giorgio, Romano; Giuseppe, Frazzetta; Giovanni, De Vita; Silvia, Di Giovanni; Daniela, Chianetta; Giuseppe, Di Buono; Vincenzo, Sorce; Gaspare, Gulotta

    2014-01-01

    Type I hiatal hernia is associated with gastroesophageal reflux disease (GERD) in 50–90% of cases. Several trials strongly support surgery as an effective alternative to medical therapy. Today, laparoscopic fundoplication is considered as the procedure of choice. However, primary laparoscopic hiatal hernia repair is associated with upto 42% recurrence rate. Mesh reinforcement of the crural closure decreases the recurrence but can lead to complications, above all nonabsorbable ones. We experiment a new totally absorbable mesh by Gore. Case. We present a case of a 65-year-old female patient with a 6-year classic history of GERD. Endoscopy revealed a large hiatal hernia and esophagitis. pH study was positive for acid reflux; esophageal manometry revealed LES intrathoracic dislocation. With laparoscopic approach, the hiatal hernia defect was identified and primarily repaired, by crural closure. Gore Bio-A Tissue Reinforcement was trimmed to fit the defect accommodating the esophagus. Nissen fundoplication was performed. Result. Bio-A mesh was easily placed laparoscopically. It has good handling and could be cut and tailored intraoperatively for optimal adaptation. There were no short-term complications. Conclusion. Crural closure reinforcement can be done readily with this new totally absorbable mesh replaced by soft tissue over six months. However, further data and studies are needed to evaluate long-term outcomes. PMID:24864221

  19. [The use of vascular prothesis Gore Viabahn in the managment of the lower limbs ischemia].

    PubMed

    Pupka, Artur; Szyber, Przemysław Piotr; Skóra, Jan; Pawłowski, Stanisław

    2011-01-01

    The chronic lower limbs ischaemia is caused mainly by arteriosclerosis. After insufficient conservative treatment only the surgical intervention can salvage the limb. The revascularisation surgery can be performed by open surgery with implantation of the prosthetic bypass or by endovascular angioplasty with stent. This second method seems to be the best alternative for the patients with several concomitant systemic diseases. Nevertheless it is limited by presence of the long-distance arteriosclerotic lesions. The resolve of that problem is use of new generation of long endovascular covered stents. They can be succesfuly used in aorto-femoral and femoro-popliteal segment. Their efficiacy is simmilar to traditional prosthetic grafts.

  20. Climate Change Draws World Attention: The 2007 Nobel Peace Award Goes to Gore and IPCC

    ERIC Educational Resources Information Center

    Bisland, Beverly Milner; Ahmad, Iftikhar

    2008-01-01

    In the fall of 2007, the Nobel Committee awarded their Peace Prize to the Intergovernmental Panel on Climate Change (a scientific intergovernmental body set up by the World Meteorological Organization and by the United Nations Environment Program) and to former Vice-President Al Gore, Jr. The committee praised the United Nations panel for creating…

  1. Gore proposes doubling U.S. effort for global programs.

    PubMed

    1999-08-06

    To confront the widespread HIV crisis, Vice President Al Gore has proposed a plan for doubling the current U.S. allocations for global programs. Seventy percent of the projected $100 million is earmarked for sub-Saharan Africa, with smaller portions going to Asia and former Soviet republics. The global campaign will address issues including containment, prevention and education efforts, and medical and psychological treatment programs. Several meetings are being scheduled with political leaders, industry, AIDS activists, and foreign leaders to address worldwide problems related to HIV. Most advocacy groups are praising the initiative, stating the U.S. is now recognizing HIV as a foreign policy priority. However, other groups are critical, and state that more funds are needed to effectively address this issue.

  2. An Alternative Technique in the Control of Massive Presacral Rectal Bleeding: Fixation of GORE-TEX® Aortic Patch.

    PubMed

    Ozsoy, Mustafa; Ozsoy, Zehra; Sahin, Suleyman; Arikan, Yüksel

    2018-01-01

    The presacral venous system is located under the pelvic fascia covering the anterior of the sacrum and consists of two lateral sacral veins, middle sacral vein, and the veins that communicate them. The presacral venous system can be easily damaged and causes serious bleeding which is difficult to control and may cause intraoperative mortality. Its incidence varies between 3% and 9.4%. Although several methods have been tried to control presacral bleeding, the definitive method of treatment has not yet been identified. We present here our alternative technique in control of massive presacral massive bleeding developed from the presacral plexus secondary to the traction of the specimen during the dissection. The bleeding could not be controlled despite the use of all technical possibilities such as packing, ligation, and hemostatic agents. Bleeding control was provided by GORE-TEX ® graft. We conclude that fıxatıon of GORE-TEX ® aortic patch should be kept in mind for uncontrolled massive presacral bleeding.

  3. Long-wavelength vertical-cavity laser research at Gore

    NASA Astrophysics Data System (ADS)

    Jayaraman, Vijaysekhar; Geske, J. C.; MacDougal, Michael H.; Peters, Frank H.; Lowes, Ted D.; Char, T. T.; Van Deusen, Dale R.; Goodnough, T.; Donhowe, Mark N.; Kilcoyne, Sean P.; Welch, David J.

    1999-04-01

    Vertical cavity surface emitting lasers (VCSELs) operating near 1310 or 1550 nm have been the subject of intensive research by multiple groups for several years. In the past year at Gore, we have demonstrated the first 1300 nm VCSELs which operate with useful power, high modulation rate, and low voltage over the commercial temperature range of 0 - 70 degree(s)C. These results have been achieved using a new structure in which an 850 nm VCSEL optical pump is integrated with the 1300 nm VCSEL. Electrical drive is applied to the 850 nm pump, and 1300 nm light is emitted from the integrated structure. This approach has resulted in over a milliwatt of single transverse mode power at room temperature, and several hundred microwatts of single transverse mode power at 70 degree(s)C. In addition, these devices demonstrate multi-gigabit modulation and excellent coupling efficiency to single-mode fiber.

  4. [Usefulness of urethral endoprosthesis in the management of urinary retention after brachytherapy for localized prostate cancer].

    PubMed

    Kerkeni, W; Chahwan, C; Lenormand, C; Dubray, B; Benyoucef, A; Pfister, C

    2014-03-01

    Brachytherapy is a possible treatment for localized low risk prostate cancer. Although this option is minimally invasive, some side effects may occur. Acute retention of urine (ARU) has been observed in 5% to 22% of cases and can be prevented in most cases by alpha-blocker treatment. Several alternatives have been reported in the literature for the management of ARU following brachytherapy: prolonged suprapubic catheterization, transurethral resection of the prostate and also intermittent self-catheterization. The authors report an original endoscopic approach, using urethral endoprosthesis, with a satisfactory voiding status. Copyright © 2013. Published by Elsevier Masson SAS.

  5. Recognizing subtle evidence for silicic magma derivation from petrochemically-similar arc crust: Isotopic and chemical evidence for the bimodal volcanic series of Gorely Volcanic Center, Kamchatka, Russia

    NASA Astrophysics Data System (ADS)

    Seligman, A. N.; Bindeman, I. N.; Ellis, B. S.; Ponomareva, V.; Leonov, V.

    2012-12-01

    The Kamchatka Peninsula is home to some of the most prolific subduction related volcanic activity in the world. Gorely caldera and its central volcano are located in the rear of its currently active Eastern Volcanic Front. Recent work determined the presence of explosive ignimbrite eruptions sourced from Gorely volcano during the Pleistocene. We studied 32 eruptive units, including tephrochronologically-dated Holocene tephra, stratigraphically-arranged ignimbrites, as well as pre- and post-caldera lavas. We analyzed oxygen isotope ratios of pyroxene and plagioclase grains by laser fluorination, and major and trace element compositions of whole rocks. In addition, we determined 87Sr/86Sr and 143Nd/144Nd ratios of caldera-forming ignimbrite eruptions. Chemical compositions show that Gorely eruptive units range from basalt to basaltic andesite in the "Pra-Gorely" stages prior to caldera formation and the modern Gorely stages forming its current edifice. In contrast, eruptive material from earlier ignimbrites exposed at Opasny Ravine consists primarily of dacite. Whole rock analyses for Gorely indicate that silicic rocks and ignimbrites volumetrically dominate all other products, forming separate bimodal peaks in our SiO2-frequency diagram. In addition, trace element concentrations and ratios define two trends, one for more silicic and another for more mafic material. δ18Omelt values range from a low of 4.85 up to 6.22‰, where the lowest value was found in the last caldera forming eruption, suggesting incorporation of hydrothermally-altered material from earlier eruptions. 87Sr/86Sr and 143Nd/144Nd ratios range from 0.70328 to 0.70351 and from 0.51303 to 0.51309 respectively, with higher and more diverse values being characteristic of earlier ignimbrite units; again suggesting incorporation of surrounding crustal material. In contrast to these results, MELTS modeling using a variety of likely primitive basalts from Gorely shows it is possible to obtain silicic

  6. Successful Antibiotic Treatment of Severe Staphylococcal Infection of a Long Stent Graft in the Superficial Femoral Artery with Graft Preservation in the Long Term

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Treitl, Marcus, E-mail: Marcus.Treitl@med.uni-muenchen.de; Rademacher, Antje; Becker-Lienau, Johanna

    2011-06-15

    Introduction: Bacterial infection of endovascular stent grafts is a serious condition, regularly leading to graft replacement by open bypass surgery.Case ReportWe describe the case of a staphylococcal infection of a 150-mm covered stent graft (Gore Viabahn), placed in the superficial femoral artery. Stent graft infection was successfully treated by oral administration of penicillinase-resistant flucloxacillin and the lipopeptide daptomycin with complete graft preservation, not requiring surgical treatment. During 1-year follow-up, the graft infection did not reappear. However, the patient developed restenosis at the proximal margin of the stent with recurrence of mild claudication, so far treated conservatively. Conclusion: With the increasedmore » use of covered stent grafts in the peripheral vasculature, the frequency of graft infection will increase. We demonstrate that with newly developed antibiotics, it is possible to treat this severe complication conservatively, with complete graft preservation and without the need for bypass surgery in selected cases.« less

  7. Endovascular treatment of a spontaneous aneurysm in the axillary artery.

    PubMed

    Park, Sung Kyun; Hwang, Jeong Kye; Park, Sun Cheol; Kim, Sang Dong

    2015-01-01

    Spontaneous aneurysm in the axillary artery is extremely rare. The standard treatment for axillary artery aneurysm has been surgical repair, but endovascular management of select aneurysms using stent grafts has become more prevalent with the development of endoluminal technology. We report the case of a 36-year old man with a spontaneous aneurysm in the axillary artery. He experienced a tingling sensation and intermittent pain in the left upper extremity and had no history of trauma to the axilla. We performed endovascular treatment [placement of a Viabahn stent graft (W.L. Gore & Associates, Flagstaff, AZ, USA)] for a spontaneous aneurysm in the axillary artery. Following the procedure, his symptoms disappeared completely. After 6, 12 and 24 months, we carried out computed tomography angiography; all scans showed no complications. Now, the patient has no symptoms related to aneurysm in the axilla. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  8. Heparin surface stent-graft for the treatment of a carotid pseudoaneurysm.

    PubMed

    Tsolaki, Elpiniki; Elpiniki, Tsolaki; Salviato, Elisabetta; Rocca, Tiberio; Braccini, Lucia; Galeotti, Roberto; Mascoli, Francesco

    2010-10-01

    Carotid pseudoaneurysms are a rare consequence of carotid surgery, trauma, and infection. Historically, carotid aneurysms and pseudoaneurysms were treated surgically. However, endovascular techniques have recently become a valid alternative for the treatment of carotid pseudoaneurysms. The case of a 57-year-old male patient with a pseudoaneurysm of the right internal carotid artery is described. The patient came to our unit with a painless and pulsatile mass in the neck, which was growing slowly. Five years earlier, he had undergone surgery on a saccular aneurysm located on the distal extracranial segment of the right internal carotid artery. The pseudoaneurysm was successfully treated with a heparin surface Viabahn stent-graft system (Gore AL, Flagstaff, AZ). Heparin surface stent-grafts can be used for the treatment of carotid lesions and may offer protection against intimal hyperplasia and thrombosis. Further studies are needed to evaluate the long-term results. Copyright © 2010 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.

  9. Benchtop quantification of gutter formation and compression of chimney stent grafts in relation to renal flow in chimney endovascular aneurysm repair and endovascular aneurysm sealing configurations.

    PubMed

    Boersen, Johannes T; Donselaar, Esme J; Groot Jebbink, Erik; Starreveld, Roeliene; Overeem, Simon P; Slump, Cornelis H; de Vries, Jean-Paul P M; Reijnen, Michel M P J

    2017-11-01

    The chimney technique has been successfully used to treat juxtarenal aortic aneurysms. The two main issues with this technique are gutter formation and chimney graft (CG) compression, which induce a risk for type Ia endoleaks and stent thrombosis, respectively. In this benchtop study, the geometry and renal artery flow of chimney endovascular aneurysm repair configurations were compared with chimney configurations with endovascular aneurysm sealing (ch-EVAS). Seven flow phantoms were constructed, including one control and six chimney endovascular aneurysm repairs (Endurant [Medtronic Inc, Minneapolis, Minn] and AFX [Endologix Inc, Irvine, Calif]) or ch-EVAS (Nellix, Endologix) configurations, combined with either balloon-expandable or self-expanding CGs with an intended higher positioning of the right CG in comparison to the left CG. Geometric analysis was based on measurements at three-dimensional computed tomography angiography and included gutter volume and CG compression, quantified by the ratio between maximal and minimal diameter (D-ratio). In addition, renal artery flow was studied in a physiologic flow model and compared with the control. The average gutter volume was 343.5 ± 142.0 mm 3 , with the lowest gutter volume in the EVAS-Viabahn (W. L. Gore & Associates, Flagstaff, Ariz) combination (102.6 mm 3 ) and the largest in the AFX-Advanta V12 (Atrium Medical Corporation, Hudson, NH) configuration (559.6 mm 3 ). The maximum D-ratio was larger in self-expanding CGs than in balloon-expandable CGs in all configurations (2.02 ± 0.34 vs 1.39 ± 0.13). The CG compression had minimal influence on renal volumetric flow (right, 390.7 ± 29.4 mL/min vs 455.1 mL/min; left, 423.9 ± 28.3 mL/min vs 410.0 mL/min in the control). This study showed that gutter volume was lowest in ch-EVAS in combination with a Viabahn CG. CG compression was lower in configurations with the Advanta V12 than with Viabahn. Renal flow is unrestricted by CG compression

  10. Candidates stick to party guns. In lieu of new healthcare plans, Bush, Gore follow party reform proposals.

    PubMed

    Gardner, J; Hallam, K

    2000-07-03

    As the Democratic and GOP nominating conventions approach next month, presumptive nominees Al Gore and George W. Bush are offering no new healthcare plans, both preferring to ride the healthcare waves already set in motion by their respective party's leadership. And the really interesting thing is, the plans aren't that different. Call it creeping incrementalism.

  11. MR safety and compatibility of a noninvasively expandable total-joint endoprosthesis.

    PubMed

    Ogg, Robert J; McDaniel, C Brian; Wallace, Donald; Pitot, Pierre; Neel, Michael D; Kaste, Sue C

    2005-09-01

    A noninvasively expandable total-joint endoprosthesis is now available for pediatric patients; the prosthesis can be lengthened by external application of a magnetic field. We investigated the risks of unintentional heating or lengthening of the prosthesis during MR imaging and evaluated the effect of the device on the diagnostic efficacy of MR imaging of surrounding tissues. We performed MR imaging at 1.5 T by using standard pulse sequences and pulse sequences with high-gradient and high-radiofrequency duty cycle. MR imaging caused no measurable change in prosthesis length, and the temperature of the prosthesis increased by less than 1 degrees C during repeated 14-min exposures. Despite significant signal loss and image distortion around the prosthetic joint, clinically useful images were obtained as close as 12 cm from the ends of the prosthetic stems, measured toward the body of the device. Thus, the prosthesis can be safely exposed to MR imaging pulse sequences at 1.5 T, and the visualization of some tissue surrounding the device is clinically useful.

  12. Initial H2O content and conditions of parent magma origin for Gorely volcano (Southern Kamchatka) estimated by trace element thermobarometry

    NASA Astrophysics Data System (ADS)

    Nazarova, D. P.; Portnyagin, M. V.; Krasheninnikov, S. P.; Mironov, N. L.; Sobolev, A. V.

    2017-01-01

    The formation conditions of the parental magmas of Gorely volcano, which is located behind a volcanic front in Southern Kamchatka, have been evaluated using the modern methods of micro-element thermobarometry. These magmas contained 1.7 ± 0.8 (2σ) wt % of H2O, the majority (82%) of which has been lost from inclusions. They crystallized at 1121 ± 17°C and an oxygen fugacity of ΔQFM 1.2 ± 0.2, and could have been produced by about 11% melting of an enriched MORB source (E-DMM) at a temperature of about 1270°C, and a pressure of about 1.5 GPa. A distinctive feature of Gorely volcano, compared with frontal volcanoes of Kamchatka, is the unusually high temperature (925 ± 20°C) of formation of the subduction component corresponding to the region of existence of water-bearing melts.

  13. [The quality management in clinical diagnostic laboratory in conditions of the Federal Center of traumatology, orthopedics and endoprosthesis replacement of Minzdrav of Russia (Cheboksary)].

    PubMed

    Nikolaev, N S; Nazarova, V V; Dobrovol'skaia, N Iu; Orlova, A V; Pchelova, N N

    2014-10-01

    The article presents experience of clinical diagnostic laboratory of the Federal Center of traumatology, orthopedics and endoprosthesis replacement of Minzdrav of Russia (Cheboksary) in the area of quality management of medical laboratory services on the basis of evaluation of efficacy and effectiveness of processes. The factors effecting quality of functioning of clinical diagnostic laboratory are indicated. The criteria and indicators of efficacy of work of employees of clinical diagnostic laboratory are presented.

  14. Solar concentrator panel and gore testing in the JPL 25-foot space simulator

    NASA Technical Reports Server (NTRS)

    Dennison, E. W.; Argoud, M. J.

    1981-01-01

    The optical imaging characteristics of parabolic solar concentrator panels (or gores) have been measured using the optical beam of the JPL 25-foot space simulator. The simulator optical beam has been characterized, and the virtual source position and size have been determined. These data were used to define the optical test geometry. The point source image size and focal length have been determined for several panels. A flux distribution of a typical solar concentrator has been estimated from these data. Aperture photographs of the panels were used to determine the magnitude and characteristics of the reflecting surface errors. This measurement technique has proven to be highly successful at determining the optical characteristics of solar concentrator panels.

  15. A tumor endoprosthesis is useful in elderly rheumatoid arthritis patient with acute intercondylar fracture of the distal femur.

    PubMed

    Wakabayashi, Hiroki; Naito, Yohei; Hasegawa, Masahiro; Nakamura, Tomoki; Sudo, Akihiro

    2012-05-01

    The purpose of this paper is to report the use of total knee arthroplasty using a tumor prosthesis in the treatment of elderly patients with an intercondylar fracture of the distal femur. Supracondylar fractures of the femur in patients with rheumatoid arthritis are difficult to treat due to joint deformity. We present outcomes for treating intercondylar fractures of the distal femur in rheumatoid arthritis patient using a tumor endoprosthesis. This technique allows early mobilization of the patient, with restoration of a good range of knee motion. A tumor prosthesis appears to be a viable treatment option for intercondylar femoral fractures in elderly patients. It is well tolerated and permits early ambulation and return to activities of daily living.

  16. Kerr-McGee and the NRC: from Indian country to Silkwood to Gore.

    PubMed

    Baer, H

    1990-01-01

    By focusing upon the Nuclear Regulatory Commission's appraisal of the Kerr-McGee Corporation's safety record in the Four Corners area and at two facilities in Oklahoma, this article examines the political economy of nuclear regulation in American society. Particular attention is given to the agency's response to intervenor groups which protested various operations at Kerr-McGee facility in Gore, Oklahoma, both prior to and following the accidental rupture of a cylinder containing uranium hexafluoride. Despite a consistent record of violations and nuclear mishaps by Kerr-McGee, the Nuclear Regulatory Commission permitted the company to essentially monitor its own activities. Rather than protecting workers and the public from the hazards of the nuclear industry, state regulation attempts to legitimize and defuse public opposition to its endeavors.

  17. Gore's Nobel May Bring Even More Attention on Campuses to Environmental Issues: Award for Combating Climate Change Implicitly Honors the Work of Academic Scientists

    ERIC Educational Resources Information Center

    Byrne, Richard; Monastersky, Richard

    2007-01-01

    When the Norwegian Nobel Committee announced that the 2007 Nobel Peace Prize would be shared by Al Gore, the former U.S. vice president, and the Intergovernmental Panel on Climate Change, the award implicitly celebrated a third party--academic institutions. Much of the research on global warming has come from university scientists, and higher…

  18. Ten Years of Experience with the GORE EXCLUDER{sup Registered-Sign} Stent-Graft for the Treatment of Aortic and Iliac Aneurysms: Outcomes from a Single Center Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maleux, G., E-mail: geert.maleux@uzleuven.be; Claes, H.; Van Holsbeeck, A.

    2012-06-15

    Purpose: This study was designed to assess the long-term outcome of selected patients with aortic, aortoiliac, and isolated common iliac aneurysms treated with the GORE EXCLUDER{sup Registered-Sign} stent-graft. Methods: Between December 1998 and June 2010, 121 nonconsecutive patients underwent insertion of a GORE EXCLUDER{sup Registered-Sign} stent-graft to treat an aortic (n = 80; 66%), aortoiliac (n = 25; 21%), or isolated common iliac (n = 16; 13%) aneurysm. Procedural and follow-up data were collected prospectively. Primary endpoints are overall survival, intervention-free survival, and freedom from aneurysm rupture. Secondary endpoints are device- and procedure-related complications, including all types of endoleaks ormore » endotension, and reintervention. Results: The mean follow-up is 4.98 years (standard deviation, 3.18; median follow-up, 4.05 years). The estimated percentage overall survival (with 95% confidence interval) after respectively 5 and 10 years of follow-up is 74.5% (65.8; 81.3) and 57.8% (47.7; 66.7). The estimated intervention-free survival after respectively 5 and 10 years is 90% (84.3; 96.1) and 77.7% (67; 88.4). There was no aneurysm rupture during follow-up. Early postoperative complications occurred in 16 patients (13%); none were fatal. Late reinterventions were performed in 18 patients (15%). Finally, throughout the follow-up period, endoleaks were identified: type I (n = 4; 3%); type II (n = 39; 32%); type III (n = 0; 0%); endotension was seen in 11 patients (9%). Conclusions: Aneurysm exclusion with use of the GORE EXCLUDER{sup Registered-Sign} stent-graft is durable through a mean follow-up of nearly 5 years. There was no postprocedural aneurysm rupture. Complications occurred throughout the follow-up period, requiring continued clinical and radiological surveillance.« less

  19. Patent foramen ovale closure with GORE HELEX or CARDIOFORM Septal Occluder vs. antiplatelet therapy for reduction of recurrent stroke or new brain infarct in patients with prior cryptogenic stroke: Design of the randomized Gore REDUCE Clinical Study.

    PubMed

    Kasner, Scott E; Thomassen, Lars; Søndergaard, Lars; Rhodes, John F; Larsen, Coby C; Jacobson, Joth

    2017-12-01

    Rationale The utility of patent foramen ovale (PFO) closure for secondary prevention in patients with prior cryptogenic stroke is uncertain despite multiple randomized trials completed to date. Aims The Gore REDUCE Clinical Study (REDUCE) aims to establish superiority of patent foramen ovale closure in conjunction with antiplatelet therapy over antiplatelet therapy alone in reducing the risk of recurrent clinical ischemic stroke or new silent brain infarct in patients who have had a cryptogenic stroke. Methods and design This controlled, open-label trial randomized 664 subjects with cryptogenic stroke at 63 multinational sites in a 2:1 ratio to either antiplatelet therapy plus patent foramen ovale closure (with GORE® HELEX® Septal Occluder or GORE® CARDIOFORM Septal Occluder) or antiplatelet therapy alone. Subjects will be prospectively followed for up to five years. Neuroimaging is required for all subjects at baseline and at two years or study exit. Study outcomes The two co-primary endpoints for the study are freedom from recurrent clinical ischemic stroke through at least 24 months post-randomization and incidence of new brain infarct (defined as clinical ischemic stroke or silent brain infarct) through 24 months. The primary analyses are an unadjusted log-rank test and a binomial test of subject-based proportions, respectively, both on the intent-to-treat population, with adjustment for testing multiplicity. Discussion The REDUCE trial aims to target a patient population with truly cryptogenic strokes. Medical therapy is limited to antiplatelet agents in both arms thereby reducing confounding. The trial should determine whether patent foramen ovale closure with the Gore septal occluders is safe and more effective than medical therapy alone for the prevention of recurrent clinical ischemic stroke or new silent brain infarct; the neuroimaging data will provide an opportunity to further support the proof of concept. The main results are anticipated in 2017

  20. Toll-like receptors and aseptic loosening of hip endoprosthesis-a potential to respond against danger signals?

    PubMed

    Lähdeoja, Tuomas; Pajarinen, Jukka; Kouri, Vesa-Petteri; Sillat, Tarvo; Salo, Jari; Konttinen, Yrjö T

    2010-02-01

    Bacterial remnants and subclinical biofilms residing on prosthesis surfaces have been speculated to play a role in hip implant loosening by opsonizing otherwise relatively inert wear particles. The innate immune system recognizes these microbial pathogen-associated molecular patterns (PAMPs) using Toll-like receptors (TLRs). Our objective was to evaluate the possible presence of TLRs in aseptic synovial membrane-like interface tissue. Bacterial culture-negative, aseptic (n = 4) periprosthetic synovial membrane-like tissue was compared to osteoarthritis synovial membrane (n = 5) for the presence of cells positive for all known human functional TLRs, stained using specific antibodies by immunohistochemistry, and evaluated using morphometry. In comparison to osteoarthtritic synovium, the number of TLR-positive cells was found to be increased in the aseptic setting, reflecting the considerable macrophage infiltration to the tissues investigated. Thus aseptic periprosthetic tissue seems to be very reactive to PAMPs. It has been recently recognized that TLR do not only respond to traditional PAMPs, but also to endogenous alarmings or danger signals released from necrotic and activated cells. Alarming-TLR interaction in the periprosthetic tissue might be a novel mechanism of aseptic loosening of endoprosthesis. (c) 2009 Orthopaedic Research Society.

  1. Squeaking friction phenomena in ceramic hip endoprosthesis: Modeling and experimental validation

    NASA Astrophysics Data System (ADS)

    Ouenzerfi, G.; Massi, F.; Renault, E.; Berthier, Y.

    2015-06-01

    minimizing friction rising factors (such edge loading and situations promoting metal transfer or stripe wear) or by developing endoprosthesis design to avoid the unstable vibrations, regressing the squeaking emission to a negligible phenomenon.

  2. Hypothermia Severely Effects Performance of Nitinol-Based Endovascular Grafts In Vitro

    PubMed Central

    Robich, Michael P.; Hagberg, Robert; Schermerhorn, Marc L.; Pomposelli, Frank B.; Nilson, Michael C.; Gendron, Michelle L.; Sellke, Frank W.; Rodriguez, Roberto

    2012-01-01

    Background Nitinol is an alloy that serves as the base for numerous medical devices, including the GORE TAG Thoracic Endoprosthesis (W.L. Gore & Associates, Flagstaff, AZ) thoracic aortic graft device. Given the increasing use of therapeutic hypothermia used during the placement these devices and in post– cardiac arrest situations, we sought to understand the impact of hypothermia on this device. Methods Five 34-mm TAG devices were deployed in a temperature-controlled chamber at 20°C, 25°C, 30°C, 35°, and 37°C (25 total devices). A halographic measurement device was used to measure radial expansive force and normalized to the force at 37°C. Three 34-mm TAG devices were similarly deployed in a temperature-controlled water bath at each of the above temperatures. A laser micrometer was utilized to measure deployed diameter. Results A statistically significant decrease in expansive force at 20°C, 25°C, and 30°C of 65%, 46%, and 6%, respectively, was noted. A statistically significant decrease in radial diameter at 20°C and 25°C of 17% and 11%, respectively, was noted. Although a 9% difference was noted at 30°C, it was not significant. Conclusions The nitinol-based TAG device shows marked decreases in radial expansive force and deployed diameter at temperatures at or below 30°C. Surgeons should be aware of the potential implications of placing nitinol-based endoprostheses in hypothermic conditions. In addition, all health care providers should be aware of the changes that occur in nitinol-based endoprostheses during therapeutic hypothermia. PMID:22385821

  3. Influence of Different Patellofemoral Design Variations Based on Genesis II Total Knee Endoprosthesis on Patellofemoral Pressure and Kinematics.

    PubMed

    Leichtle, Ulf G; Lange, Barbara; Herzog, Yvonne; Schnauffer, Peter; Leichtle, Carmen I; Wülker, Nikolaus; Lorenz, Andrea

    2017-01-01

    In total knee arthroplasty (TKA), patellofemoral groove design varies greatly and likely has a distinct influence on patellofemoral biomechanics. To analyse the selective influence, five patellofemoral design variations were developed based on Genesis II total knee endoprosthesis (original design, being completely flat, being laterally elevated, being medially elevated, and both sides elevated) and made from polyamide using rapid prototyping. Muscle-loaded knee flexion was simulated on 10 human knee specimens using a custom-made knee simulator, measuring the patellofemoral pressure distribution and tibiofemoral and patellofemoral kinematics. The measurements were carried out in the native knee as well as after TKA with the 5 design prototypes. The overall influence of the different designs on the patellofemoral kinematics was small, but we found detectable effects for mediolateral tilt ( p < 0.05 for 35°-80° flexion) and translation of the patella ( p < 0.045 for 20°-65° and 75°-90°), especially for the completely flat design. Considering patellofemoral pressures, major interindividual differences were seen between the designs, which, on average, largely cancelled each other out. These results suggest that the elevation of the lateral margin of the patellofemoral groove is essential for providing mediolateral guidance, but smooth contouring as with original Genesis II design seems to be sufficient. The pronounced interindividual differences identify a need for more patellofemoral design options in TKA.

  4. Influence of Different Patellofemoral Design Variations Based on Genesis II Total Knee Endoprosthesis on Patellofemoral Pressure and Kinematics

    PubMed Central

    Lange, Barbara; Herzog, Yvonne; Schnauffer, Peter; Leichtle, Carmen I.; Wülker, Nikolaus

    2017-01-01

    In total knee arthroplasty (TKA), patellofemoral groove design varies greatly and likely has a distinct influence on patellofemoral biomechanics. To analyse the selective influence, five patellofemoral design variations were developed based on Genesis II total knee endoprosthesis (original design, being completely flat, being laterally elevated, being medially elevated, and both sides elevated) and made from polyamide using rapid prototyping. Muscle-loaded knee flexion was simulated on 10 human knee specimens using a custom-made knee simulator, measuring the patellofemoral pressure distribution and tibiofemoral and patellofemoral kinematics. The measurements were carried out in the native knee as well as after TKA with the 5 design prototypes. The overall influence of the different designs on the patellofemoral kinematics was small, but we found detectable effects for mediolateral tilt (p < 0.05 for 35°–80° flexion) and translation of the patella (p < 0.045 for 20°–65° and 75°–90°), especially for the completely flat design. Considering patellofemoral pressures, major interindividual differences were seen between the designs, which, on average, largely cancelled each other out. These results suggest that the elevation of the lateral margin of the patellofemoral groove is essential for providing mediolateral guidance, but smooth contouring as with original Genesis II design seems to be sufficient. The pronounced interindividual differences identify a need for more patellofemoral design options in TKA. PMID:28255225

  5. Vertebral Augmentation with Nitinol Endoprosthesis: Clinical Experience in 40 Patients with 1-Year Follow-up

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anselmetti, Giovanni Carlo, E-mail: gc.anselmetti@fastwebnet.it; Manca, Antonio, E-mail: anto.manca@gmail.com; Marcia, Stefano, E-mail: stemarcia@gmail.com

    PurposeThis study was designed to assess the clinical outcomes of patients treated by vertebral augmentation with nitinol endoprosthesis (VNE) to treat painful vertebral compression fractures.MethodsForty patients with one or more painful osteoporotic VCF, confirmed by MRI and accompanied by back-pain unresponsive to a minimum 2 months of conservative medical treatment, underwent VNE at 42 levels. Preoperative and postoperative pain measured with Visual Analog Scale (VAS), disability measured by Oswestry Disability Index (ODI), and vertebral height restoration (measured with 2-dimensional reconstruction CT) were compared at last follow-up (average follow-up 15 months). Cement extravasation, subsequent fractures, and implant migration were recorded.ResultsLong-term follow-up was obtainedmore » in 38 of 40 patients. Both VAS and ODI significantly improved from a median of 8.0 (range 5–10) and 66 % (range 44–88 %) to 0.5 (range 0–8) and 6 % (range 6–66 %), respectively, at 1 year (p < 0.0001). Vertebral height measurements comparing time points increased in a statistically significant manner (ANOVA, p < 0.001). Overall cement extravasation rate was 9.5 %. Discal and venous leakage rates were 7.1 and 0 % respectively. No symptomatic extravasations occurred. Five of 38 (13.1 %) patients experienced new spontaneous, osteoporotic fractures. No device change or migration was observed.ConclusionsVNE is a safe and effective procedure that is able to provide long-lasting pain relief and durable vertebral height gain with a low rate of new fractures and cement leakages.« less

  6. A recurrent empyema with peripheral bronchopleural fistulas treated by retrograde bronchial sealing with Gore Tex plugs: a case report

    PubMed Central

    Ahn, Jin-Young; Kim, Dohun; Hong, Jong-Myeon

    2015-01-01

    Bronchopleural fistulae (BPF) are communications between the bronchial tree and the pleural spaces. This anomaly is associated with significant morbidity and mortality, and its management in some patients remains a major therapeutic challenge for clinicians. Here we report a case involving a 62-year-old man with chronic empyema associated with multiple BPF caused by severe necrotizing pneumonia with parapneumonic effusion in the left lower lobe. His BPF were treated by decortication and retrograde surgical sealing with Gore-Tex plugs that were sutured to the parenchyma and bronchus and reinforced by glue and an intercostal muscle flap. The air leakage stopped immediately after surgery and the chronic empyema resolved. His subsequent postoperative course was uneventful, and he was discharged 14 days after surgery. At the 8-month follow-up visit, stable surgical outcomes with no BPF recurrence were observed. In summary, we described a novel and easy surgical technique for the repair of intractable peripheral BPF in select patients. PMID:26793385

  7. In Vitro Quantification of Gutter Formation and Chimney Graft Compression in Chimney EVAR Stent-Graft Configurations Using Electrocardiography-Gated Computed Tomography.

    PubMed

    Overeem, Simon P; Donselaar, Esmé J; Boersen, Jorrit T; Groot Jebbink, Erik; Slump, Cornelis H; de Vries, Jean-Paul P M; Reijnen, Michel M P J

    2018-03-01

    To assess the dynamic behavior of chimney grafts during the cardiac cycle. Three chimney endovascular aneurysm repair (EVAR) stent-graft configurations (Endurant and Advanta V12, Endurant and Viabahn, and Endurant and BeGraft) were placed in silicone aneurysm models and subjected to physiologic flow. Electrocardiography (ECG)-gated contrast-enhanced computed tomography was used to visualize geometric changes during the cardiac cycle. Endograft and chimney graft surface, gutter volume, chimney graft angulation over the center lumen line, and the D-ratio (the ratio between the lengths of the major and minor axes) were independently assessed by 2 observers at 10 time points in the cardiac cycle. Both gutter volumes and chimney graft geometry changed significantly during the cardiac cycle in all 3 configurations (p<0.001). Gutters and endoleaks were observed in all configurations. The largest gutter volume (232.8 mm 3 ) and change in volume (20.7 mm 3 ) between systole and diastole were observed in the Endurant-Advanta configuration. These values were 2.7- and 3.0-fold higher, respectively, compared to the Endurant-Viabahn configuration and 1.7- and 1.6-fold higher as observed in the Endurant-BeGraft configuration. The Endurant-Viabahn configuration had the highest D-ratio (right, 1.26-1.35; left, 1.33-1.48), while the Endurant-BeGraft configuration had the lowest (right, 1.11-1.17; left, 1.08-1.15). Assessment of the interobserver variability showed a high correlation (intraclass correlation >0.935) between measurements. Gutter volumes and stent compression are dynamic phenomena that reshape during the cardiac cycle. Compelling differences were observed during the cardiac cycle in all configurations, with the self-expanding (Endurant-Viabahn) chimney EVAR configurations having smaller gutters and less variation in gutter volume during the cardiac cycle yet more stent compression without affecting the chimney graft surface.

  8. Clinical trial comparing autogenous fascia lata sling and Gore-Tex suspension in bilateral congenital ptosis.

    PubMed

    Elsamkary, Mahmoud Ahmed; Roshdy, Maged Maher Salib

    2016-01-01

    To study the effect of autogenous fascia lata sling (AFLS) versus Gore-Tex suspension (GTS) regarding the functional and aesthetic outcomes in patients with bilateral congenital ptosis. A prospective comparative randomized single-center study enrolled 110 patients with bilateral congenital ptosis. One group (n=55) underwent AFLS and the second group (n=55) underwent GTS. Exclusion criteria were good levator function, absent Bell's phenomenon, and abnormal ocular motility. Follow-up period was 2 years. Functional outcome was measured from digital photos by analysis of upper eyelid margin position relative to the superior limbus and classified as very good (<3 mm), good (3-5 mm), poor (>5 mm), and recurrent. Aesthetic outcome was assessed in terms of lid contour, symmetry of eyelid height, and lid crease presence. Complications were also reported. Failure rate (recurrence and complications) was less in AFLS (P=0.035). Symmetrical lid height and good contour were more frequently attained by AFLS (P=0.007 and 0.047, respectively). However, the frequency of very good, good, poor, recurrence, lagopthalmos, ectropion, infection, and formed lid crease individually showed no statistically significant difference (P=0.252, 0.482, 1, 0.489, 0.438, 1, 0.618, and 0.506, respectively). AFLS is a better choice in surgery for patients with bilateral congenital ptosis because it has fewer complications and a lesser recurrence rate than GTS.

  9. Primary paraesophageal hernia repair with Gore® Bio-A® tissue reinforcement: long-term outcomes and association of BMI and recurrence.

    PubMed

    Olson, Michael T; Singhal, Saurabh; Panchanathan, Roshan; Roy, Sreeja Biswas; Kang, Paul; Ipsen, Taylor; Mittal, Sumeet K; Huang, Jasmine L; Smith, Michael A; Bremner, Ross M

    2018-05-14

    Laparoscopic repair remains the gold-standard treatment for paraesophageal hernia (PEH). We analyzed long-term symptomatic outcomes and surgical reintervention rates after primary PEH repair with onlay synthetic bioabsorbable mesh (W. L. Gore & Associates, Inc., Flagstaff, AZ) and examined body mass index (BMI) as a possible risk factor for poor outcomes and for recurrence. We queried a prospectively maintained database to identify patients who underwent laparoscopic primary PEH repair with onlay patch of a bioprosthetic absorbable mesh (Bio-A® Gore®) between 05/28/2009 and 12/31/2013. Electronic health records were accessed to record demographic and operative data and were reviewed up to the present to identify any repeat procedures. Patients were grouped according to preoperative BMI (A: BMI < 25; B: BMI = 25-29.9; C: BMI = 30-34.9; D: BMI ≥ 35). Patients completed standardized satisfaction and symptom surveys. In total, 399 patients were included. Most patients (n = 261; 65.4%) were women. Mean age was 59.6 ± 13.4 years; mean BMI was 29.9 ± 5.0 kg/m 2 . The patients were grouped as follows: A, 53 patients (13.3%); B, 166 (41.6%); C, 115 (28.8%); D: 65 (16.3%). Four procedures (1.0%) were converted from laparoscopy to open procedures. All patients underwent an antireflux procedure (225 Nissen, 170 Toupet, 4 Dor). A mean follow-up of 44.7 ± 22.8 months was available for 305 patients (76.4%). 24/305 patients (7.9%) underwent reoperation, and the number of reoperations did not differ among groups (P = 0.64). Long-term symptomatic outcomes were available for 217/305 patients (71.1%) at a mean follow-up of 54.0 ± 13.1  months; no significant difference was observed among groups. 194/217 patients (89.4%) reported good to excellent satisfaction, with no significant differences among the groups. Laparoscopic primary PEH repair with onlay Bio-A® mesh is a safe and feasible procedure with excellent long

  10. [Polyethylene abrasion: cause or consequence of an endoprosthesis loosening? Investigations of firm and loosened hip implants].

    PubMed

    Busse, B; Niecke, M; Püschel, K; Delling, G; Katzer, A; Hahn, M

    2007-01-01

    Periprosthetic tissue was analysed by the combination of different investigation techniques without destruction. The localisation and geometry of polyethylene abrasion particles were determined quantitatively to differentiate between abrasion due to function and abrasion due to implant loosening. Non-polyethylene particles from implant components which contaminate the tissue were micro-analytically measured. The results will help us to understand loosening mechanisms and thus lead to implant optimisations. A non-destructive particle analysis using highly sensitive proton-induced X-ray emission (PIXE) was developed to achieve a better histological allocation. Five autopsy cases with firmly fitting hip endoprosthesis (2 x Endo-Modell Mark III, 1 x St. Georg Mark II, LINK, Germany; 2 x Spongiosa Metal II, ESKA, Germany) were prepared as ground tissue specimens. Wear investigations were accomplished with a combined application of different microscopic techniques and microanalysis. The abrasion due to implant loosening was histologically evaluated on 293 loosened cup implants (St. Georg Mark II, LINK, Germany). Wear particles are heterogeneously distributed in the soft tissue. In cases of cemented prostheses, cement particles are dominating whereas metal particles could rarely be detected. The concentration of the alloy constituent cobalt (Co) is increased in the mineralised bone tissue. The measured co-depositions depend on the localisation and/or lifetime of an implant. Functional polyethylene (PE) abrasion needs to be differentiated from PE abrasion of another genesis (loosening, impingement) morphologically and by different tissue reactions. In the past a reduction of abrasion was targeted primarily by the optimisation of the bearing surfaces and tribology. The interpretation of our findings indicates that different mechanisms of origin in terms of tissue contamination with wear debris and the alloy should be included in the improvement of implants or implantation

  11. Anti-inflammatory and Antibacterial Effects of Covalently Attached Biomembrane-Mimic Polymer Grafts on Gore-Tex Implants.

    PubMed

    Jin, Young Ju; Kang, Sunah; Park, Pona; Choi, Dongkil; Kim, Dae Woo; Jung, Dongwook; Koh, Jaemoon; Jeon, Joohee; Lee, Myoungjin; Ham, Jiyeon; Seo, Ji-Hun; Jin, Hong-Ryul; Lee, Yan

    2017-06-07

    Expanded polytetrafluoroethylene (ePTFE), also known as Gore-Tex, is widely used as an implantable biomaterial in biomedical applications because of its favorable mechanical properties and biochemical inertness. However, infection and inflammation are two major complications with ePTFE implantations, because pathogenic bacteria can inhabit the microsized pores, without clearance by host immune cells, and the limited biocompatibility can induce foreign body reactions. To minimize these complications, we covalently grafted a biomembrane-mimic polymer, poly(2-methacryloyloxylethyl phosphorylcholine) (PMPC), by partial defluorination followed by UV-induced polymerization with cross-linkers on the ePTFE surface. PMPC grafting greatly reduced serum protein adsorption as well as fibroblast adhesion on the ePTFE surface. Moreover, the PMPC-grafted ePTFE surface exhibited a dramatic inhibition of the adhesion and growth of Staphylococcus aureus, a typical pathogenic bacterium in ePTFE implants, in the porous network. On the basis of an analysis of immune cells and inflammation-related factors, i.e., transforming growth factor-β (TGF-β) and myeloperoxidase (MPO), we confirmed that inflammation was efficiently alleviated in tissues around PMPC-grafted ePTFE plates implanted in the backs of rats. Covalent PMPC may be an effective strategy for promoting anti-inflammatory and antibacterial functions in ePTFE implants and to reduce side effects in biomedical applications of ePTFE.

  12. Emergency Pancreatico-Duodenectomy with Superior Mesenteric and Portal Vein Resection and Reconstruction Using a Gore-Tex Vascular Graft.

    PubMed

    Eftimie, Mihai Adrian; Lungu, Vasile; Tudoroiu, Marian; Vatachki, Genady; Batca, Severina; David, Leonard

    2017-01-01

    Emergency pancreatico-duodenectomy(EPD) is a very rare procedure and few reports are present in medical literature. It is an uncommon approach, usually used for emergency surgical treatment of abdominal trauma that involves the head of the pancreas or the duodenum, but it is also a surgical tool for the treatment of ruptured aneurysms, bleeding pseudocysts, duodenal perforations, uncontrollable hemorrhage from ulcers and tumors, severe infectious complications of acute pancreatitis or endoscopic retrograde cholangiopancreatography related complications (1,2). It is rarely used as the first line of treatment in case of acute bleeding from arterial pseudoaneurysm of the cephalad region of the pancreas. We present the case of a bleeding pseudoaneurysm of the cefalic region of the pancreas in a young patient with previously undiagnosed chronic pancreatitis and with suspicion of a malignant process located in the head of the pancreas. We performed a pancreatico-duodenectomy with resection of superior mesenteric and portal vein with reconstruction using Gore-Tex vascular graft due to probable venous abutment. Postoperative course was without any major complications, only minor grad-I pancreatic fistula was present. We determine that EPD is a useful tool in the treatment of such cases. It can be used as a first line of treatment or secondary to endovascular stenting or embolization. Celsius.

  13. Evaluating the time and temperature dependent biaxial strength of Gore-Select ® series 57 proton exchange membrane using a pressure loaded blister test

    NASA Astrophysics Data System (ADS)

    Grohs, Jacob R.; Li, Yongqiang; Dillard, David A.; Case, Scott W.; Ellis, Michael W.; Lai, Yeh-Hung; Gittleman, Craig S.

    Temperature and humidity fluctuations in operating fuel cells impose significant biaxial stresses in the constrained proton exchange membranes (PEMs) of a fuel cell stack. The strength of the PEM, and its ability to withstand cyclic environment-induced stresses, plays an important role in membrane integrity and consequently, fuel cell durability. In this study, a pressure loaded blister test is used to characterize the biaxial strength of Gore-Select ® series 57 over a range of times and temperatures. Hencky's classical solution for a pressurized circular membrane is used to estimate biaxial strength values from burst pressure measurements. A hereditary integral is employed to construct the linear viscoelastic analog to Hencky's linear elastic exact solution. Biaxial strength master curves are constructed using traditional time-temperature superposition principle techniques and the associated temperature shift factors show good agreement with shift factors obtained from constitutive (stress relaxation) and fracture (knife slit) tests of the material.

  14. An Unusual Endovascular Therapeutic Approach for a Rare Case of May-Thurner Syndrome.

    PubMed

    DaSilva-DeAbreu, Adrian; Masha, Luke; Peerbhai, Shareez

    2017-03-06

    BACKGROUND The etiology of deep venous thrombosis (DVT) may pose a significant diagnostic challenge because truly reversible causes of DVT are rare. In this regard, known pelvic anatomic abnormalities such as aortic and iliac aneurysms should be seriously considered as a complicating factor in patients presenting with acute DVT so as not to miss a potentially curable etiology of May-Thurner syndrome (MTS). CASE REPORT We report the case of a 69-year-old man with a known abdominal aortic aneurysm and bilateral iliac artery aneurysms who presented with an acute DVT. A computed tomography scan of the abdomen and pelvis showed increased dilation of his aneurysmal disease with new resultant compression of the left iliac vein representing acquired MTS. The patient underwent endovascular aneurysm repair of the infra-renal abdominal aortic aneurysm and right common iliac artery aneurysm with a Gore Excluder endoprosthesis in lieu of venous stenting, with resolution of symptoms. CONCLUSIONS Infra-renal aortic and iliac aneurysms causing MTS are extremely rare, and patients at risk for MTS through these mechanisms do not fit the classical demographics associated with this syndrome. Furthermore, this is the first case described in which MTS was treated by addressing the aneurysm through an endoprosthetic approach instead of venous stenting, which is the conventional intervention for MTS.

  15. Proximal protection with the Gore PAES can reduce DWI lesion size in high-grade stenosis during carotid stenting.

    PubMed

    Grunwald, Iris Quasar; Reith, Wolfgang; Kühn, Anna Luisa; Balami, Joyce S; Karp, Kerstin; Fassbender, Klaus; Walter, Silke; Papanagiotou, Panagiotis; Krick, Christoph

    2014-06-01

    The aim was to determine the incidence of new ischaemic lesions on diffusion-weighted MR imaging (DWI) in a non-randomised cohort of patients after protected and unprotected carotid artery stent placement using the Parodi Anti-Emboli System (PAES). A retrospective review was conducted on 269 patients who received DWI prior to, and 24-72 hours after, stent placement. All patients were enrolled in one centre. Forty patients stented with the PAES device were matched with 229 patients stented without protection (control group). New diffusion restriction on DWI was detected in 25.8% (PAES) versus 32.3% (control group); p=0.64. On average there were 0.7 lesions (PAES) versus 0.8 lesions (control group) per patient. The area of lesions was 1.7 (PAES) versus 5.6 mm2. In a subanalysis of patients (32 PAES, 148 non-protected) with >80% stenosis, the area of restricted diffusion was less when proximal protection was used (p<0.05). The number and area of DWI lesions did not differ on the contralateral, non-stented side. When the PAES system was used, patients were more likely not to have any lesion at all (p=0.028). In high-grade stenosis, the use of the Gore PAES device significantly reduced the area of new DWI lesions and patients were more likely not to have any new DWI lesion at all.

  16. [The long-term results and indications for use of Gore-Texgrafts in the femoropopliteal position in patients with atherosclerotic lesion of lower limb arteries].

    PubMed

    Pokrovskiĭ, A V; Dan, V N; Zotikov, A E; Chupin, A V; Shubin, A A; Chikharev, M V

    2004-01-01

    Presented herein are the long-term results of femoropopliteal reconstructions above the knee joint fisure in patients with atherosclerotic lesion of the femoropopliteal segment using Gore-Tex grafts. The retrospective study accrued 108 patients. Of these, IIB degree lower limb ischemia (according to the A.V. Pokrovsky classification) was initially present in 64 (60.2%) and critical ischemia in 52 (40.8%) patients. Patients suffering from lower limb ischemia of varying degree did not significantly differ in the age or coexistent diseases. The mean value of the ankle/brachial index (ABI) accounted for 0.46+/-0.23 in patients with IIB degree ischemia and for 0.40+/-0.27 in patients with critical lower limb ischemia. All the patients were evaluated for the condition of the distal bed according to the scheme proposed by Rutherford et al. in 1997. The patients were distributed into three groups: patients with "good" runoff (from 1 to 4 points, n=65), patients with "satisfactory" runoff (from 5 to 7 points, n=36), and those with an "unsatisfactory" condition of the distal bed (runoff point over 7, n=7). The long-term results were assessed in 81 (75%) patients over the period as long as 105 months. The mean follow up accounted for 58,4 months. One year later the graft patency in the total patient group constituted 73.1%, after 3 years it was equal to 54.8%, and after 5 years to 49.9%. It is demonstrated that the initial runoff point exerted a significant effect on the graft patency. It is noteworthy that in patients with an initially "good" runoff point, 57.5% of the grafts were patent 5 years after operation whereas in patients with a "satisfactory" point only 35.3% turned out patent (p<0.05). Patients with an initially "unsatisfactory" runoff point developed thrombosis of all grafts over the period as long as 6 months following operation. The five-year limb salvage was observed in 77.6% of patients. It has been revealed over the 5-year period that the degree of initial

  17. Histological Evaluation of a Self-Expanding Stent-Graft 23 Months After Implantation in the Superficial Femoral Artery.

    PubMed

    Ishihara, Takayuki; Iida, Osamu; Inoue, Katsumi; Fujita, Masashi; Masuda, Masaharu; Okamoto, Shin; Nanto, Kiyonori; Kanda, Takashi; Tsujimura, Takuya; Sunaga, Akihiro; Mano, Toshiaki; Uematsu, Masaaki

    2017-10-01

    To report histological examination of a Viabahn stent-graft implanted in the superficial femoral artery (SFA) for nearly 2 years. A 78-year-old man with peripheral artery disease was treated successfully with a 6.0×250-mm Viabahn self-expanding stent-graft in the right SFA, relieving his lower limb claudication. The patient died suddenly due to acute myocardial infarction 23 months later. Histological evaluation of the stent-graft implantation site revealed moderate neointimal proliferation at both proximal and distal edges of the device. In the middle part of the stent, significant macrophages and multinucleated foreign body giant cells had accumulated, although the stent was entirely patent. Furthermore, no endothelial cell coverage was found. Judging from these features, it might be necessary to continue dual antiplatelet therapy after stent-graft implantation over the long term to prevent thrombosis and subsequent restenosis or reocclusion.

  18. Surveillance Duplex Ultrasonography of Stent Grafts for Popliteal Aneurysms.

    PubMed

    Pineda, Danielle M; Troutman, Douglas A; Dougherty, Matthew J; Calligaro, Keith D

    2016-05-01

    Stent grafts, also known as covered stents, have become an increasingly acceptable treatment for popliteal artery aneurysms. However, endovascular exclusion confers lower primary patency compared to traditional open bypass and exclusion. The purpose of this study was to evaluate whether duplex ultrasonography (DU) can reliably diagnose failing stent grafts placed for popliteal artery aneurysms prior to occlusion. Between June 5, 2007, and March 11, 2014, 21 stent grafts (Viabahn; Gore, Flagstaff, Arizona) were placed in 19 patients for popliteal artery aneurysms. All patients had at least 1 follow-up duplex scan postoperatively. Mean follow-up was 28.9 months (9-93 months). Postoperative DU surveillance was performed in our Intersocietal Accreditation Commission noninvasive vascular laboratory at 1 week postprocedure and every 6 months thereafter. Duplex ultrasonography measured peak systolic velocities (PSVs) and ratio of adjacent PSVs (Vr) every 5 cm within the stent graft and adjacent arteries. We retrospectively classified the following factors as "abnormal DU findings": focal PSV > 300 cm/s, uniform PSVs < 50 cm/s throughout the graft, and Vr > 3.0. These DU criteria were derived from laboratory-specific data that we previously published on failing stent grafts placed for lower extremity occlusive disease. Four of the 21 stent grafts presented with symptomatic graft thrombosis within 6 months of a normal DU. Three of these 4 patients presented with rest pain and underwent thrombectomy (2) or vein bypass (1), and 1 elected for nonintervention for claudication. Our results suggest that surveillance DU using criteria established for grafts placed for occlusive disease may not be useful for predicting stent graft failure in popliteal artery aneurysms. © The Author(s) 2016.

  19. Stent Design Affects Femoropopliteal Artery Deformation.

    PubMed

    MacTaggart, Jason; Poulson, William; Seas, Andreas; Deegan, Paul; Lomneth, Carol; Desyatova, Anastasia; Maleckis, Kaspars; Kamenskiy, Alexey

    2018-03-23

    Poor durability of femoropopliteal artery (FPA) stenting is multifactorial, and severe FPA deformations occurring with limb flexion are likely involved. Different stent designs result in dissimilar stent-artery interactions, but the degree of these effects in the FPA is insufficiently understood. To determine how different stent designs affect limb flexion-induced FPA deformations. Retrievable markers were deployed into n = 28 FPAs of lightly embalmed human cadavers. Bodies were perfused and CT images were acquired with limbs in the standing, walking, sitting, and gardening postures. Image analysis allowed measurement of baseline FPA foreshortening, bending, and twisting associated with each posture. Markers were retrieved and 7 different stents were deployed across the adductor hiatus in the same limbs. Markers were then redeployed in the stented FPAs, and limbs were reimaged. Baseline and stented FPA deformations were compared to determine the influence of each stent design. Proximal to the stent, Innova, Supera, and SmartFlex exacerbated foreshortening, SmartFlex exacerbated twisting, and SmartControl restricted bending of the FPA. Within the stent, all devices except Viabahn restricted foreshortening; Supera, SmartControl, and AbsolutePro restricted twisting; SmartFlex and Innova exacerbated twisting; and Supera and Viabahn restricted bending. Distal to the stents, all devices except AbsolutePro and Innova exacerbated foreshortening, and Viabahn, Supera, Zilver, and SmartControl exacerbated twisting. All stents except Supera were pinched in flexed limb postures. Peripheral self-expanding stents significantly affect limb flexion-induced FPA deformations, but in different ways. Although certain designs seem to accommodate some deformation modes, no device was able to match all FPA deformations.

  20. Automated Acquisition of Proximal Femur Morphological Characteristics

    NASA Astrophysics Data System (ADS)

    Tabakovic, Slobodan; Zeljkovic, Milan; Milojevic, Zoran

    2014-10-01

    The success of the hip arthroplasty surgery largely depends on the endoprosthesis adjustment to the patient's femur. This implies that the position of the femoral bone in relation to the pelvis is preserved and that the endoprosthesis position ensures its longevity. Dimensions and body shape of the hip joint endoprosthesis and its position after the surgery depend on a number of geometrical parameters of the patient's femur. One of the most suitable methods for determination of these parameters involves 3D reconstruction of femur, based on diagnostic images, and subsequent determination of the required geometric parameters. In this paper, software for automated determination of geometric parameters of the femur is presented. Detailed software development procedure for the purpose of faster and more efficient design of the hip endoprosthesis that ensures patients' specific requirements is also offered

  1. Method and apparatus for an inflatable shell

    NASA Technical Reports Server (NTRS)

    Johnson, Christopher J. (Inventor)

    2012-01-01

    A method of assembling an inflatable shell of a structure comprises folding a plurality of shell sections about a set of fold lines and integrating the plurality of shell sections together with one another to form the shell. In another embodiment, an inflatable shell comprises a plurality of shell sections, each shell section having two pairs of fold lines for folding into stowage comprising a first gore section having a plurality of first gore panels layered and collectively folded about at a first set of fold lines. Each layer of the first gore panels and second gore panels are configured such that, once the first gore panel and second gore panel are attached to one another at the respective side edges of each panel, the lines of attachment forming a second set of fold lines for the shell section. A system and method for fabricating gore panels is also disclosed.

  2. Edge Stenosis After Covered Stenting for Long Superficial Femoral Artery Occlusive Disease: Risk Factor Analysis and Prevention With Drug-Coated Balloon Angioplasty.

    PubMed

    Lin, Ting-Chao; Huang, Chun-Yang; Chen, Po-Lin; Lee, Chiu-Yang; Shih, Chun-Che; Chen, I-Ming

    2018-06-01

    To report a retrospective analysis of risk factors for edge restenosis after Viabahn stent-graft treatment of superficial femoral artery (SFA) occlusive disease and determine any protective effect of drug-coated balloons (DCBs) used at the time of stent-graft implantation. Between October 2011 and July 2016, 110 patients (mean age 73.3±7.6 years; 78 men) were treated with the Viabahn stent-graft for long SFA occlusions. Thirty-eight (34.5%) patients had DCB reinforcement at the distal edge of the stent-graft. For analysis, the population was divided into groups of no edge stenosis patients (n=88; mean lesion length 22.4±4.2 cm) and edge stenosis patients (n=22; mean lesion length 23.5±5.7 cm). The clinical outcomes, ankle-brachial indices, computed tomography angiography findings, and patency were compared at a minimum of 12 months. Logistic regression analysis was employed to determine risk factors for edge stenosis; the results are presented as the odds ratio (OR) and 95% confidence interval. No differences in clinical or procedural characteristics were identified except the higher incidence of diabetes (p=0.008) and greater need for retrograde access (p=0.033) in the edge stenosis group. DCB reinforcement reduced the incidence of edge stenosis (p=0.021) and target lesion revascularization (TLR; p=0.010) and resulted in a significantly higher 1-year primary patency rate (92.1% vs 76.4%, p=0.042). However, multivariate analysis revealed only poor distal runoff (OR 0.31, 95% CI 0.11 to 0.83, p=0.020) as a predictor of edge stenosis. The risk of edge stenosis after Viabahn implantation was higher in patients with poor distal runoff. DCB reinforcement over the distal edge reduced edge stenosis, decreased 1-year TLR, and improved 1-year primary patency.

  3. Advanced solar concentrator: Preliminary and detailed design

    NASA Technical Reports Server (NTRS)

    Bell, D. M.; Maraschin, R. A.; Matsushita, M. T.; Erskine, D.; Carlton, R.; Jakovcevic, A.; Yasuda, A. K.

    1981-01-01

    A single reflection point focusing two-axis tracking paraboloidal dish with a reflector aperture diameter of approximately 11 m has a reflective surface made up of 64 independent, optical quality gores. Each gore is a composite of a thin backsilvered mirror glass face sheet continuously bonded to a contoured substrate of lightweight, rigid cellular glass. The use of largely self-supporting gores allows a significant reduction in the weight of the steel support structure as compared to alternate design concepts. Primary emphasis in the preliminary design package for the low-cost, low-weight, mass producible concentrator was placed on the design of the higher cost subsystems. The outer gore element was sufficiently designed to allow fabrication of prototype gores.

  4. One-step endosonography-guided drainage of a pancreatic pseudocyst: a new technique of stent delivery through the echo endoscope.

    PubMed

    Vilmann, P; Hancke, S; Pless, T; Schell-Hincke, J D; Henriksen, F W

    1998-10-01

    We report here the first case of a one-step endosonography(EUS)-guided pseudocyst drainage. A prototype large channel curved array echo endoscope (Pentax FG-38 UX) and a prototype delivery system for placement of an endoprosthesis was used for the procedure. The delivery system (GIP MedicinTechnik GmbH/Medi-Globe Corporation) consists of a handle part with a piston, a metal ring sheath, a plastic catheter with a diathermy needle and a double pigtail endoprosthesis (8.5 Fr). When mounted on the endoscope the endoprosthesis can be advanced out of the distal end of the endoscope. The introduction of the stent as well as the stent release can be monitored entirely by ultrasound. The procedure was tested in a 76-year-old woman with a pseudocyst measuring 60 mm in diameter located in the tail of the pancreas. The procedure was well tolerated by the patient, and there were no procedural complications. The advantage of a large channel echo endoscope and our new prototype delivery system is that the endoprosthesis can be inserted in to a pancreatic cyst guided exclusively by EUS without exchange of endoscopes, catheters or guide wires. Further studies are warranted.

  5. Geologic map of the Vail East quadrangle, Eagle County, Colorado

    USGS Publications Warehouse

    Kellogg, Karl S.; Bryant, Bruce; Redsteer, Margaret H.

    2003-01-01

    New 1:24,000-scale geologic mapping along the Interstate-70 urban corridor in western Colorado, in support of the State/USGS Cooperative Geologic Mapping Project, is contributing to a more complete understanding of the stratigraphy, structure, tectonic evolution, and hazard potential of this rapidly developing region. The 1:24,000-scale Vail East quadrangle straddles the Gore fault system, the western structural boundary of the Gore Range. The Gore fault system is a contractional structure that has been recurrently active since at least the early Paleozoic and marks the approximate eastern boundary of the Central Colorado trough, a thick late Paleozoic depocenter into which thousands of meters of clastic sediment were deposited from several uplifts, including the ancestral Front Range. The Gore fault was active during both the late Paleozoic and Upper Cretaceous-lower Tertiary (Laramide) deformations. In addition, numerous north-northwest faults that cut the crystalline rocks of the Gore Range were active during at least 5 periods, the last of which was related to Neogene uplift of the Gore Range and formation of the northern Rio Grande rift. Early Proterozoic crystalline rocks underlie the high Gore Range, north and east of the Gore fault system. These rocks consist predominantly of migmatitic biotite gneiss intruded by mostly granitic rocks of the 1.667-1.750 Ma Cross Creek batholith, part of the 1,667-1,750 Ma Routt Plutonic Suite (Tweto, 1987). Southwest of the Gore fault, a mostly gently south-dipping sequence of Pennsylvanian Mimturn Formation, as thick as 1,900 m, and the Permian and Pennsylvanian Maroon Formation (only the basal several hundred meters are exposed in the quadrangle)were shed from the ancestral Front Range and overlie a thin sequence of Devonian and Cambrian rocks. The Minturn Formation is a sequence of interlayered pink, maroon, and gray conglomerate, sandstone, shale, and marine limestone. The Maroon Formation is mostly reddish conglomerate

  6. Saturn S-2 production operations techniques: Production welding. Volume 1: Bulkhead welding

    NASA Technical Reports Server (NTRS)

    Abel, O. G.

    1970-01-01

    The complex Saturn S-2 welding processes and procedures required considerable development and refinement to establish a production capability that could consistently produce aluminum alloy welds within specified requirements. The special processes and techniques are defined that were established for the welding of gore-to-gore and manhole- or closeout-to-gore.

  7. [Acute cholangitis in interstenosis space accompanied by two-component unit of the main bile duct].

    PubMed

    Yurchenko, V V

    2016-02-01

    Palliative treatment of obstructive jaundice with the help of biliary endoprosthesis due to the possible complication of post-intervention in the form of insolvency stent deformation or dislocation. The study features in the postoperative period of the main bile duct endoprosthesis about their two-component unit, described the syndrome of the closed space of the bile ducts. On the basis of observation of 14 patients with the given anatomical feature of endoscopic, who were underwent stenting, was assessed frequency of the syndrome and possibilities of its prevention. Interstenosis space expansion of the main bile duct can be a reason for local cholangitis. For the prevention of cholangitis, it should be carried out a separate drainage of interstenosis space with the help of endoprosthesis or by proximal supra-stenotic extension of two or more stents.

  8. Individual Passive Chemical Sampler Testing Continued Chemical Agent and TIC Performance Validation

    DTIC Science & Technology

    2002-04-01

    period of high temperature, although the atmosphere was wet. 4.3 Post-Deployment Activities The deployment of the samplers did not go as...4.4 Day 0 Adsorption and Recovery Comparison Between Gore Low-Level and Gore High -Level Samplers at Varying Temperatures...43 Figure 4.5 Day 0 Adsorption and Recovery Comparison Between SKC High Level and Gore High -Level Samplers

  9. Emergency Nightmares - Rupture of Type III Thoracoabdominal Aneurysm.

    PubMed

    Dias-Neto, Marina; Ramos, José Fernando; Rocha Neves, João; Almeida, Pedro; Rocha E Silva, Augusto; Teixeira, José Fernando

    2017-01-01

    Introduction The rupture of thoracoabdominal aneurysms (rTAA) represents one of the major challenges to the vascular surgeon. Recent developments in the endovascular armamentarium and the high mortality from open surgery make endovascular treatment an attractive option. Devices to be used in an emergency environment should be "off-the-shelf" and include, among others, EVAR snorkel/chimney and branched endoprosthesis (T-branch, Cook®). We describe the case of a 70-year-old patient who was admitted to the emergency room due continuous low back pain with 3 days of evolution. The tomographic computer angiography showed a type III thoracoabdominal aneurysm, with a transverse maximum diameter of 75x81mm in the infrarenal aorta and an exuberant hematoma in the left retroperitoneum, but no active extravasation of the contrast was observed (Figure 1). There was still marked tortuosity and moderate iliac calcification. It was decided to place a branched endoprosthesis (34 mm diameter at the top and 18 mm at the bottom). The branched endoprosthesis was extra-corporeally oriented, and introduced through a right femoral approach. The final position was verified with the digital subtraction angiography in anteroposterior incidence, ensuring that the distal border of each branch was 1.5 to 2 cm above the target vessel and that the stent marks presented the desired position. After the endoprosthesis was opened, the branches are catheterized by the left axillary access, however, it was verified that the endoprosthesis had an antero-posteriorly inverted implantation. It was possible to catheterize the superior mesenteric artery and the left renal artery (celiac trunk occlusion was documented intraoperatively); occlusion of the remaining endoprosthesis branches was performed with an Amplatzer. The patient evolved with multiorgan dysfunction and died at 24 hours post-operatively. Implantation of an off-the-shelf branched endoprosthesis requires specific anatomical criteria such as

  10. Development of Non-Optimum Factors for Launch Vehicle Propellant Tank Bulkhead Weight Estimation

    NASA Technical Reports Server (NTRS)

    Wu, K. Chauncey; Wallace, Matthew L.; Cerro, Jeffrey A.

    2012-01-01

    Non-optimum factors are used during aerospace conceptual and preliminary design to account for the increased weights of as-built structures due to future manufacturing and design details. Use of higher-fidelity non-optimum factors in these early stages of vehicle design can result in more accurate predictions of a concept s actual weights and performance. To help achieve this objective, non-optimum factors are calculated for the aluminum-alloy gores that compose the ogive and ellipsoidal bulkheads of the Space Shuttle Super-Lightweight Tank propellant tanks. Minimum values for actual gore skin thicknesses and weld land dimensions are extracted from selected production drawings, and are used to predict reference gore weights. These actual skin thicknesses are also compared to skin thicknesses predicted using classical structural mechanics and tank proof-test pressures. Both coarse and refined weights models are developed for the gores. The coarse model is based on the proof pressure-sized skin thicknesses, and the refined model uses the actual gore skin thicknesses and design detail dimensions. To determine the gore non-optimum factors, these reference weights are then compared to flight hardware weights reported in a mass properties database. When manufacturing tolerance weight estimates are taken into account, the gore non-optimum factors computed using the coarse weights model range from 1.28 to 2.76, with an average non-optimum factor of 1.90. Application of the refined weights model yields non-optimum factors between 1.00 and 1.50, with an average non-optimum factor of 1.14. To demonstrate their use, these calculated non-optimum factors are used to predict heavier, more realistic gore weights for a proposed heavy-lift launch vehicle s propellant tank bulkheads. These results indicate that relatively simple models can be developed to better estimate the actual weights of large structures for future launch vehicles.

  11. [Stress analysis on the acetabular side of bipolar hemiarthroplasty by the two-dimensional finite element method incorporating the boundary friction layer].

    PubMed

    Ichihashi, K; Imura, S; Oomori, H; Gesso, H

    1994-11-01

    We compared the biomechanical characteristics of bipolar and unipolar hemiarthroplasty on the proximal migration of the outer head by determining the von Mises stress distribution and acetabular (outer head) displacement with clinical assessment of hemiarthroplasty in 75 patients. This analysis used the two-dimensional finite element method, which incorporated boundary friction layers on both the inner and outer bearings of the prosthesis. Acetabular reaming increased stress within the pelvic bone and migration of the outer head. A combination of the acetabular reaming and bone transplantation increased the stress within the pelvic bone and grafted bone, and caused outer head migration. These findings were supported by clinical results. Although the bipolar endoprosthesis was biomechanically superior to the unipolar endoprosthesis, migration of the outer head still occurred. The bipolar endoprosthesis appeared to be indicated in cases of a femoral neck fracture or of avascular necrosis in the femoral head, but its use in cases of osteoarthritis in the hip required caution.

  12. Linking Goal-Oriented Requirements and Model-Driven Development

    NASA Astrophysics Data System (ADS)

    Pastor, Oscar; Giachetti, Giovanni

    In the context of Goal-Oriented Requirement Engineering (GORE) there are interesting modeling approaches for the analysis of complex scenarios that are oriented to obtain and represent the relevant requirements for the development of software products. However, the way to use these GORE models in an automated Model-Driven Development (MDD) process is not clear, and, in general terms, the translation of these models into the final software products is still manually performed. Therefore, in this chapter, we show an approach to automatically link GORE models and MDD processes, which has been elaborated by considering the experience obtained from linking the i * framework with an industrially applied MDD approach. The linking approach proposed is formulated by means of a generic process that is based on current modeling standards and technologies in order to facilitate its application for different MDD and GORE approaches. Special attention is paid to how this process generates appropriate model transformation mechanisms to automatically obtain MDD conceptual models from GORE models, and how it can be used to specify validation mechanisms to assure the correct model transformations.

  13. GORE Flow Reversal System and GORE Embolic Filter Extension Study

    ClinicalTrials.gov

    2016-01-22

    Carotid Stenosis; Constriction, Pathologic; Carotid Artery Diseases; Cerebrovascular Disorders; Brain Diseases; Central Nervous System Diseases; Nervous System Diseases; Arterial Occlusive Diseases; Vascular Diseases; Cardiovascular Diseases; Pathological Conditions, Anatomical

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maleux, Geert; Pirenne, Jacques; Vaninbroukx, Johan

    Our purpose was to assess the feasibility of orthotopic liver transplantation (OLT) in patients priorly having undergone transjugular intrahepatic portosystemic shunt (TIPS) with an expanded tetrafluoroethylene (e-PTFE)-covered endoprosthesis. In 48 patients an e- PTFE-covered endoprosthesis was inserted to treat severe complications of portal hypertension. In 36 patients the endoprosthesis was inserted during TIPS creation (de novo TIPS); in the other 12 patients the endoprosthesis was placed to repermeabilize the previously created, but occluded bare stent (revision TIPS). Eight of them (5 de novo and 3 revision cases) later underwent an OLT. The hospital records of these patients were reviewed frommore » initial admission, through TIPS, the pre-OLT period, and OLT to current postoperative status. Five de novo and 3 revision cases underwent OLT 4-279 days (mean delay: 80.8 days) after TIPS procedure. All OLT's were performed under veno-venous bypass surgery. De visu surgical inspection confirmed correct positioning of the fully patent stent graft, starting in the portal vein and ending at the junction of the hepatic vein to the inferior caval vein. No surgical difficulty was observed during proximal or distal clamping or during resection of the diseased liver. Correctly positioned e-PTFE-covered nitinol endoprostheses do not interfere with a later OLT and may not be considered as a contraindication in patients who need a TIPS as a bridge to OLT.« less

  15. Time-dependent strains and stresses in a pumpkin balloon

    NASA Technical Reports Server (NTRS)

    Gerngross, T.; Xu, Y.; Pellegrino, S.

    2006-01-01

    This paper presents a study of pumpkin-shaped superpressure balloons, consisting of gores made from a thin polymeric film attached to high stiffness, meridional tendons. This type of design is being used for the NASA ULDB balloons. The gore film shows considerable time-dependent stress relaxation, whereas the behaviour of the tendons is essentially time-independent. Upon inflation and pressurization, the "instantaneous", i.e. linear-elastic strain and stress distribution in the film show significantly higher values in the meridional direction. However, over time, and due to the biaxial visco-elastic stress relaxation of the the material, the hoop strains increase and the meridional stresses decrease, whereas the remaining strain and stress components remain substantially unchanged. These results are important for a correct assessment of the structural integrity of a pumpkin balloon in a long-duration mission, both in terms of the material performance and the overall stability of the shape of the balloon. An experimental investigation of the time dependence of the biaxial strain distribution in the film of a 4 m diameter, 48 gore pumpkin balloon is presented. The inflated shape of selected gores has been measured using photogrammetry and the time variation in strain components at some particular points of these gores has been measured under constant pressure and temperature. The results show good correlation with a numerical study, using the ABAQUS finite-element package, that includes a widely used model of the visco-elastic response of the gore material:

  16. Treatments to reduce the frequency of freeway exit sign hits.

    DOT National Transportation Integrated Search

    2011-06-01

    Exit gore signs present a significant maintenance challenge for TxDOT. There is concern regarding the safety : of personnel working in gore areas to replace these signs, and the resources necessary for continual : maintenance. The objective of this p...

  17. Expandable endoprostheses in malignant bone tumors in children: indications and limitations.

    PubMed

    Baumgart, Rainer; Lenze, Ulrich

    2009-01-01

    Expandable endoprostheses can be an option after resection of malignant bone tumors of the lower extremity in children and adolescents not only to bridge the resultant surgical defect but also to correct a residual limb length discrepancy. Small intramedullary diameter and short residual bone segments, as well as stress-shielding, are intrinsic technical limitations of fully implantable reconstructive devices. As a consequence, until recently, repeated operative interventions to reconstruct the limb and compensate for subsequent absence of growth within the affected limb were required to compensate for continued growth of the contralateral limb. Innovative expandable endoprosthetic devices are now available to help achieve equal limb length at maturity. One common device is a conventional endoprosthesis that is lengthened using a telescopic module, whereas the "bioexpandable" system lengthens the remaining bone using a lengthening nail as a modular part of the endoprosthesis. Both systems are equipped with motor drives that electromagnetic waves activate transcutaneously. One advantage of the "bioexpandable" endoprosthesis is that with sequential lengthening, the proportion of residual bone shaft to prosthesis length increases, thereby diminishing host bone-endoprosthetic lever arm forces.

  18. Rotating mandrel speeds assembly of plastic inflatables

    NASA Technical Reports Server (NTRS)

    Mac Fadden, J. A.; Stenlund, S. J.; Wendt, A. J.

    1966-01-01

    Rotating mandrel permits the accurate cutting, forming, and sealing of plastic gores for assembly of an inflatable surface of revolution. The gores remain on the mandrel until the final seam is reached. Tolerances are tightly controlled by the mandrel configuration.

  19. We must speak of hope as well as catastrophe.

    PubMed

    Rafferty, Anne Marie

    2017-08-23

    Al Gore, the former US vice-president and now campaigner on climate change, has just released a follow-up to his groundbreaking 2006 documentary An Inconvenient Truth. Gore's first film won an Oscar and grossed $49 million - astonishing for a documentary.

  20. An Unusual Endovascular Therapeutic Approach for a Rare Case of May-Thurner Syndrome

    PubMed Central

    DaSilva-DeAbreu, Adrian; Masha, Luke; Peerbhai, Shareez

    2017-01-01

    Patient: Male, 69 Final Diagnosis: May-Thurner syndrome secondary to left common iliac artery aneurysm Symptoms: Left lower extremity edema • left lower extremity erythema • left lower extremity pain Medication: — Clinical Procedure: Endovascular aneurysm repair (EVAR) of the infra-renal abdominal aorta aneurysm and right common iliac artery aneurysm Specialty: Cardiology Objective: Unknown ethiology Background: The etiology of deep venous thrombosis (DVT) may pose a significant diagnostic challenge because truly reversible causes of DVT are rare. In this regard, known pelvic anatomic abnormalities such as aortic and iliac aneurysms should be seriously considered as a complicating factor in patients presenting with acute DVT so as not to miss a potentially curable etiology of May-Thurner syndrome (MTS). Case Report: We report the case of a 69-year-old man with a known abdominal aortic aneurysm and bilateral iliac artery aneurysms who presented with an acute DVT. A computed tomography scan of the abdomen and pelvis showed increased dilation of his aneurysmal disease with new resultant compression of the left iliac vein representing acquired MTS. The patient underwent endovascular aneurysm repair of the infra-renal abdominal aortic aneurysm and right common iliac artery aneurysm with a Gore Excluder endoprosthesis in lieu of venous stenting, with resolution of symptoms. Conclusions: Infra-renal aortic and iliac aneurysms causing MTS are extremely rare, and patients at risk for MTS through these mechanisms do not fit the classical demographics associated with this syndrome. Furthermore, this is the first case described in which MTS was treated by addressing the aneurysm through an endoprosthetic approach instead of venous stenting, which is the conventional intervention for MTS. PMID:28260745

  1. Effective treatment of benign biliary strictures with a removable, fully covered, self-expandable metal stent: A prospective, multicenter European study.

    PubMed

    Schmidt, Arthur; Pickartz, Tilman; Lerch, Markus M; Fanelli, Fabrizio; Fiocca, Fausto; Lucatelli, Pierleone; Cereatti, Fabrizio; Hoffmeister, Albrecht; van Steenbergen, Werner; Kraft, Matthias; Meier, Benjamin; Caca, Karel

    2017-04-01

    Temporary placement of removable, fully covered, self-expandable metal stents (fcSEMS) for treatment of benign biliary strictures (BBS) has been reported to be effective. However, the optimal extraction time point remains unclear and stent migration has been a major concern. The objective of this study was to evaluate the efficacy and safety of this treatment modality using an fcSEMS with a special antimigration design and prolonged stent indwell time. We performed a prospective, single-arm study at six tertiary care centers in Europe. Patients with BBS underwent endoscopic or percutaneous implantation of an fcSEMS (GORE® VIABIL® Biliary Endoprosthesis, W.L. Gore & Associates, Flagstaff, AZ, USA). The devices were scheduled to be removed nine months later, and patients were to return for follow-up for an additional 15 months. Forty-three patients were enrolled in the study. Stricture etiology was chronic pancreatitis in the majority of patients (57.5%). All fcSEMS were placed successfully, either endoscopically (76.7%) or percutaneously (23.3%). Stent migration was observed in two patients (5.2%). Primary patency of the SEMS prior to removal was 73.0%. All attempted stent removals were successful. At removal, stricture was resolved or significantly improved without need for further therapy in 78.9% of patients. Stricture recurrence during a follow-up of two years post-implant was observed in two patients. Temporary placement of the fcSEMS is a feasible, safe and effective treatment for BBS. The design of the device used in this study accounts for very low migration rates and facilitates easy stent retrieval, even after it has been in place for up to 11 months.

  2. Effective treatment of benign biliary strictures with a removable, fully covered, self-expandable metal stent: A prospective, multicenter European study

    PubMed Central

    Schmidt, Arthur; Pickartz, Tilman; Lerch, Markus M; Fanelli, Fabrizio; Fiocca, Fausto; Lucatelli, Pierleone; Cereatti, Fabrizio; Hoffmeister, Albrecht; van Steenbergen, Werner; Kraft, Matthias; Meier, Benjamin

    2016-01-01

    Background Temporary placement of removable, fully covered, self-expandable metal stents (fcSEMS) for treatment of benign biliary strictures (BBS) has been reported to be effective. However, the optimal extraction time point remains unclear and stent migration has been a major concern. Objective The objective of this study was to evaluate the efficacy and safety of this treatment modality using an fcSEMS with a special antimigration design and prolonged stent indwell time. Methods We performed a prospective, single-arm study at six tertiary care centers in Europe. Patients with BBS underwent endoscopic or percutaneous implantation of an fcSEMS (GORE® VIABIL® Biliary Endoprosthesis, W.L. Gore & Associates, Flagstaff, AZ, USA). The devices were scheduled to be removed nine months later, and patients were to return for follow-up for an additional 15 months. Results Forty-three patients were enrolled in the study. Stricture etiology was chronic pancreatitis in the majority of patients (57.5%). All fcSEMS were placed successfully, either endoscopically (76.7%) or percutaneously (23.3%). Stent migration was observed in two patients (5.2%). Primary patency of the SEMS prior to removal was 73.0%. All attempted stent removals were successful. At removal, stricture was resolved or significantly improved without need for further therapy in 78.9% of patients. Stricture recurrence during a follow-up of two years post-implant was observed in two patients. Conclusions Temporary placement of the fcSEMS is a feasible, safe and effective treatment for BBS. The design of the device used in this study accounts for very low migration rates and facilitates easy stent retrieval, even after it has been in place for up to 11 months. PMID:28507752

  3. A prospective study on the effectiveness of cotton versus waterproof cast padding in maintaining the reduction of pediatric distal forearm fractures.

    PubMed

    Robert, Christopher E; Jiang, Jimmy J; Khoury, Joseph G

    2011-03-01

    Distal forearm fractures, one of the most common fractures seen in the pediatric population, are regularly treated by closed reduction and casting. Our study investigates the effectiveness of Gore-Tex-lined casting in maintaining the reduction of 100% displaced distal forearm fractures compared with traditional cotton-lined casts. We screened all patients from February 2007 to July 2009 who presented to Children's Hospital in Birmingham, AL with a distal radius fracture. Only patients with 100% displaced distal radius fractures were eligible to be assigned to either the cotton-lined or Gore-Tex-lined cast groups. Power analysis was performed to identify an adequate patient sample size. The mean maximum change between initial post-reduction x-rays and follow-up x-rays for anterior-posterior (AP) angulation, AP displacement, lateral angulation, and lateral displacement of the radius were calculated for both cotton and Gore-Tex groups. The rate of subsequent intervention and/or unacceptable results for each group was also analyzed. Seven hundred and twenty-two patients were treated with distal radius fractures at our hospital with 59 patients eligible for inclusion in our study. Thirty-six of our patients were treated with cotton-lined casts, and 23 patients were treated with Gore-Tex-lined cast. The mean maximum change in AP angulation, AP displacement, lateral angulation, and lateral displacement of the radius after initial reduction was 9.2 degrees, 6.9%, 13.9 degrees, and 13.6%, respectively, for the cotton-lined cast group and 7.7 degrees, 6.1%, 14.6 degrees, and 9.6%, respectively, for the Gore-Tex-lined cast group. There were no statistical differences between the means of the 4 measurements (P=0.33, 0.69, 0.73, and 0.10, respectively). There were also no significant differences between groups for final AP and lateral angulation and displacement. Subgroup analysis showed no significant differences in all measurements between cotton and Gore-Tex groups. Gore

  4. [Dynamic radioulnar convergence after Darrach operation, soft tissue stabilizing operations of the distal ulna and ulnar head prosthesis implantation--an experimental biomechanical study].

    PubMed

    Sauerbier, M; Hahn, M E; Fujita, M; Neale, P G; Germann, G; An, K N; Berger, R A

    2002-08-01

    The most common method of treating the arthrotic distal radioulnar joint (DRUJ) is resection of the entire ulnar head (Darrach procedure). Complications related to instability of the distal forearm resulting from loss of the ulnar head are usually manifested by pain and weak grip strength and have remained the drawbacks of this procedure. In an attempt to mechanically stabilize the distal forearm, an endoprosthesis was developed to replace the ulnar head after Darrach resection. The purpose of this study was to: 1) evaluate the dynamic effects of the Darrach procedure on radioulnar convergence; and 2) evaluate the mechanical efficacy of two soft tissue stabilizing techniques (Pronator quadratus advancement flap and ECU/FCU tenodesis) for the unstable distal ulnar stump and 3) the stability after the implantation of an ulnar head endoprosthesis following a Darrach resection on radioulnar convergence. With a dynamic PC-controled forearm simulator the rotation of 7 fresh-frozen cadaver upper extremities was actively and passively performed while loading relevant muscles. Resultant total forearm torque and the 3-dimensional kinematics of the ulna, radius and third metacarpal were recorded simultaneously. The implantation of the ulnar head endoprosthesis effectively restored the stability of the DRUJ. There were significantly better results after the implantation of the prosthesis compared with the Darrach and the soft tissue stabilization procedures. This study provides laboratory validity to the option of implanting an ulnar head endoprosthesis as an attempt to stabilize the distal forearm after Darrach resection in lieu of performing soft tissue stabilization techniques.

  5. Experimental studies on BrO/Br ratios at Stromboli, Etna, Masaya, Gorely and Nyiragongo

    NASA Astrophysics Data System (ADS)

    Bobrowski, Nicole; Wittmer, Julian; Liotta, Marcello; Calabrese, Sergio; Giuffrida, Giovanni; Brusca, Lorenzo; Platt, Ulrich

    2014-05-01

    on the degassing of magmatic bodies inside the Earth. First results indicate that the BrO/SO2 ratio is close to a temporarily equilibrium already after only few minutes of the gas emission from the vent (e.g. Bobrowski and Giuffrida, 2012). This equilibrium seems to be relatively independent from meteorological parameters except for extreme conditions. We here present an empirical approach to answer the above question by discussing BrO formation studies from five different volcanoes, Stromboli and Etna (Italy), Masaya (Nicaragua), Gorely (Russia) and Nyiragongo (DR Congo). These volcanoes have a broad variation in their geological settings, surrounding environment and climate. They cover subduction related systems and rift volcanism and encompass climate zones from the subarctic to the tropics. For the BrO studies Multi-Axis-Differential Optical Absorption Spectroscopy (MAX-DOAS) measurements have been carried out. Active alkaline traps were applied to determine bromine emissions at the crater rim. All measurements have been taken simultaneously or within a maximum time distance of a few hours. From these measurements we determined that a range of about 5 to 30 percent of the total bromine is transformed into BrO. We show and discuss how the varying BrO-Br partition is related partly to the geological settings, the various meteorological conditions and explore further possible influences. We will shortly discuss the current limitations of the commonly used measurement techniques itself and introduce possible future improvements.

  6. The Presidential Sweepstakes 2000.

    ERIC Educational Resources Information Center

    Doyle, Denis P.

    2000-01-01

    In the 2000 presidential campaigns, both Vice-President Al Gore and Texas Governor George W. Bush want to enlarge the federal role in education. In separate essays, Bush and Gore explain their plans to invest more federal dollars in improving poor children's educational progress and opportunities. (MLH)

  7. Application of individually performed acrylic cement spacers containing 5% of antibiotic in two-stage revision of hip and knee prosthesis due to infection.

    PubMed

    Babiak, Ireneusz

    2012-07-03

    Deep infection of a joint endoprosthesis constitutes a threat to the stability of the implant and joint function. It requires a comprehensive and interdisciplinary approach, involving the joint revision and removal of the bacterial biofilm from all tissues, the endoprosthesis must be often removed and bone stock infection treated. The paper presents the author's experience with the use of acrylic cement spacers, custom-made during the surgery and containing low dose of an antibiotic supplemented with 5% of a selected, targeted antibiotic for the infection of hip and knee endoprostheses. 33 two-stage revisions of knee and hip joints with the use of a spacer were performed. They involved 24 knee joints and 9 hip joints. The infections were mostly caused by staphylococci MRSA (18) and MSSA (8), and in some cases Enterococci (4), Salmonella (1), Pseudomonas (1) and Acinetobacter (1). The infection was successfully treated in 31 out of 33 cases (93.93%), including 8 patients with the hip infection and 23 patients with the knee infection. The endoprosthesis was reimplanted in 30 cases: for 7 hips and 23 knees, in 3 remaining cases the endoprosthesis was not reimplanted. Mechanical complications due to the spacer occurred in 4 cases: 3 dislocations and 1 fracture (hip spacer). The patients with hip spacers were ambulatory with a partial weight bearing of the operated extremity and those with knee spacers were also ambulatory with a partial weight bearing, but the extremity was initially protected by an orthosis. The spacer enables to maintain a limb function, and making it by hand allows the addition of the specific bacteria targeted antibiotic thus increasing the likelihood of the effective antibacterial treatment.

  8. Endovascular approach to treat ascending aortic pseudoaneurysm in a patient with previous CABG and very high surgical risk.

    PubMed

    Zago, Alexandre C; Saadi, Eduardo K; Zago, Alcides J

    2011-10-01

    Pseudoaneurysm of the ascending aorta is an uncommon pathology and a challenge in high-risk patients who undergo conventional surgery because of high operative morbidity and mortality. Endovascular exclusion of an aortic pseudoaneurysm using an endoprosthesis is a less invasive approach, but few such cases have been reported. Moreover, the use of this approach poses unique therapeutic challenges because there is no specific endoprosthesis for ascending aortic repair, particularly to treat patients with previous coronary artery bypass graft (CABG). We describe the case of a 74-year-old patient who had undergone CABG and later presented with an iatrogenic ascending aortic pseudoaneurysm that occurred during an angiography. This patient was at very high risk for surgical treatment and, therefore, an endovascular approach was adopted: percutaneous coronary intervention for the left main coronary artery, left anterior descending and left circumflex native coronary arteries followed by endovascular endoprosthesis deployment in the ascending aorta to exclude the pseudoaneurysm. Both procedures were successfully performed, and the patient was discharged without complications 4 days later. At 5 months' clinical follow-up, his clinical condition was good and he had no complications. Copyright © 2011 Wiley-Liss, Inc.

  9. Hydrocarbon Fuel Chemistry: Sediment Water Interaction

    DTIC Science & Technology

    1981-11-01

    applicable to some soils. Goring and Hamaker (I 7) propose that, in some cases, mineral phases of soils make a siynificant contribution to adsorption...832, 1979. Goring, C. A. I., and Hamaker , J. W., eds. "Adsorption," in Organic Chemicals in the Soil Environment, Vol. 1. New York: Marcel Dekker, Inc

  10. Politics and the Environmental Agenda.

    ERIC Educational Resources Information Center

    Rogers, Adam

    1992-01-01

    Discusses the role of environmental protection in the 1992 presidential election. Includes an analysis of the positions taken by George Bush and Dan Quayle, Bill Clinton and Al Gore. Presents George Bush's "environmental" record during his tenure as President of the United States as well as those of Quayle, Gore, and Clinton. (MCO)

  11. Comparison of femoropopliteal artery stents under axial and radial compression, axial tension, bending, and torsion deformations.

    PubMed

    Maleckis, Kaspars; Deegan, Paul; Poulson, William; Sievers, Cole; Desyatova, Anastasia; MacTaggart, Jason; Kamenskiy, Alexey

    2017-11-01

    High failure rates of Peripheral Arterial Disease (PAD) stenting appear to be associated with the inability of certain stent designs to accommodate severe biomechanical environment of the femoropopliteal artery (FPA) that bends, twists, and axially compresses during limb flexion. Twelve Nitinol stents (Absolute Pro, Supera, Lifestent, Innova, Zilver, Smart Control, Smart Flex, EverFlex, Viabahn, Tigris, Misago, and Complete SE) were quasi-statically tested under bench-top axial and radial compression, axial tension, bending, and torsional deformations. Stents were compared in terms of force-strain behavior, stiffness, and geometrical shape under each deformation mode. Tigris was the least stiff stent under axial compression (6.6N/m axial stiffness) and bending (0.1N/m) deformations, while Smart Control was the stiffest (575.3N/m and 105.4N/m, respectively). Under radial compression Complete SE was the stiffest (892.8N/m), while Smart Control had the lowest radial stiffness (211.0N/m). Viabahn and Supera had the lowest and highest torsional stiffness (2.2μNm/° and 959.2μNm/°), respectively. None of the 12 PAD stents demonstrated superior characteristics under all deformation modes and many experienced global buckling and diameter pinching. Though it is yet to be determined which of these deformation modes might have greater clinical impact, results of the current analysis may help guide development of new stents with improved mechanical characteristics. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Aortic Arch Morphology and Aortic Length in Patients with Dissection, Traumatic, and Aneurysmal Disease.

    PubMed

    Alberta, H B; Takayama, T; Smits, T C; Wendorff, B B; Cambria, R P; Farber, M A; Jordan, W D; Patel, V; Azizzadeh, A; Rovin, J D; Matsumura, J S

    2015-12-01

    To assess aortic arch morphology and aortic length in patients with dissection, traumatic injury, and aneurysm undergoing TEVAR, and to identify characteristics specific to different pathologies. This was a retrospective analysis of the aortic arch morphology and aortic length of dissection, traumatic injury, and aneurysmal patients. Computed tomography imaging was evaluated of 210 patients (49 dissection, 99 traumatic injury, 62 aneurysm) enrolled in three trials that received the conformable GORE TAG thoracic endoprosthesis. The mean age of trauma patients was 43 ± 19.6 years, 57 ± 11.7 years for dissection and 72 ± 9.6 years for aneurysm patients. A standardized protocol was used to measure aortic arch diameter, length, and take-off angle and clockface orientation of branch vessels. Differences in arch anatomy and length were assessed using ANOVA and independent t tests. Of the 210 arches evaluated, 22% had arch vessel common trunk configurations. The aortic diameter and the distance from the left main coronary (LMC) to the left common carotid (LCC) were greater in dissection patients than in trauma or aneurysm patients (p < .001). Aortic diameter in aneurysm patients was greater compared with trauma patients (p < .05). The distances from the branch vessels to the celiac artery (CA) were greater in dissection and aneurysm patients than in trauma patients (p < .001). The take-off angle of the innominate (I), LCCA, and left subclavian (LS) were greater, between 19% and 36%, in trauma patients than in dissection and aneurysm patients (p < .001). Clockface orientation of the arch vessels varies between pathologies. Arch anatomy has significant morphologic differences when comparing aortic pathologies. Describing these differences in a large sample of patients is beneficial for device designs and patient selection. Copyright © 2015 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  13. Towards computer-assisted surgery in shoulder joint replacement

    NASA Astrophysics Data System (ADS)

    Valstar, Edward R.; Botha, Charl P.; van der Glas, Marjolein; Rozing, Piet M.; van der Helm, Frans C. T.; Post, Frits H.; Vossepoel, Albert M.

    A research programme that aims to improve the state of the art in shoulder joint replacement surgery has been initiated at the Delft University of Technology. Development of improved endoprostheses for the upper extremities (DIPEX), as this effort is called, is a clinically driven multidisciplinary programme consisting of many contributory aspects. A part of this research programme focuses on the pre-operative planning and per-operative guidance issues. The ultimate goal of this part of the DIPEX project is to create a surgical support infrastructure that can be used to predict the optimal surgical protocol and can assist with the selection of the most suitable endoprosthesis for a particular patient. In the pre-operative planning phase, advanced biomechanical models of the endoprosthesis fixation and the musculo-skeletal system of the shoulder will be incorporated, which are adjusted to the individual's morphology. Subsequently, the support infrastructure must assist the surgeon during the operation in executing his surgical plan. In the per-operative phase, the chosen optimal position of the endoprosthesis can be realised using camera-assisted tools or mechanical guidance tools. In this article, the pathway towards the desired surgical support infrastructure is described. Furthermore, we discuss the pre-operative planning phase and the per-operative guidance phase, the initial work performed, and finally, possible approaches for improving prosthesis placement.

  14. A deadly disease that is getting deadlier.

    PubMed

    1999-01-01

    In her role as President Clinton's mental health policy advisor, Tipper Gore underscores the data that show HIV is still a prevalent problem, despite new treatments and declining numbers of infections. Approximately 33 million people world wide are HIV-infected, and in the U.S. 40,000 people are infected each year. Gore credits the Clinton administration with support and funding for anti-HIV efforts, and urges adults to inform children about the disease.

  15. Prevention of postoperative pericardial adhesions with TachoSil.

    PubMed

    Kuschel, Tarah J; Gruszka, Anna; Hermanns-Sachweh, Benita; Elyakoubi, Jaouad; Sachweh, Joerg S; Vázquez-Jiménez, Jaime F; Schnoering, Heike

    2013-01-01

    The prevention of the pericardial adhesions largely accountable for the technical difficulty and risk of injury inherent to resternotomy continues to gain in importance with the increasing frequency of reoperations. The hemostatic sponge TachoSil (Nycomed Austria GmbH, Linz, Austria), has shown promising results in adhesion prevention in several regions of the body. This study was designed to evaluate its effectiveness in the prevention of pericardial adhesions in comparison with the Gore-Tex (W. L. Gore and Assoc, Flagstaff, AZ) surgical membrane and a control. Twenty-four rabbits were distributed into 3 groups: TachoSil, Gore-Tex, or no barrier agent (control). After median sternotomy and pericardiotomy, the cardial surface was exposed to the aggravating effects of room air, irrigation, and gauze abrasion for one hour. A pericardial defect was created and repaired with one of the barrier agents, or left uncovered (control). Resternotomy was performed after 6 months for the evaluation of adhesion formation. Significantly fewer macroscopic adhesions were observed with TachoSil than Gore-Tex in all regions (p < 0.05) excluding the coronary arteries, where the difference in favor of TachoSil did not achieve significance (0.05< p-value <0.10). TachoSil also demonstrated significantly fewer retrosternal adhesions than the control, as well as a universal non-significant trend of fewer adhesions in all regions. The limited lesions present in the TachoSil group were filmy in nature and removed with blunt dissection relatively easily. No significant differences were found between Gore-Tex and the control. Microscopically, the least pronounced fibrosis formation and inflammatory reaction was detected with TachoSil. TachoSil is effective in the prevention of pericardial adhesions. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  16. Static and quasi-static analysis of lobed-pumpkin balloon

    NASA Astrophysics Data System (ADS)

    Nakashino, Kyoichi; Sasaki, Makoto; Hashimoto, Satoshi; Saito, Yoshitaka; Izutsu, Naoki

    The present study is motivated by the need to improve design methodology for super pressure balloon with 3D gore design concept, currently being developed at the Scientific Balloon Center of ISAS/JAXA. The distinctive feature of the 3-D gore design is that the balloon film has excess materials not only in the circumferential direction but also in the meridional direction; the meridional excess is gained by attaching the film boundaries to the corresponding tendons of a shorter length with a controlled shortening rate. The resulting balloon shape is a pumpkin-like shape with large bulges formed between adjacent tendons. The balloon film, when fully inflated, develops wrinkles in the circumferential direction over its entire region, so that the stresses in the film are limited to a small amount of uniaxial tension in the circumferential direction while the high meridional loads are carried by re-enforced tendons. Naturally, the amount of wrinkling in the film is dominated by the shortening rate between the film boundaries and the tendon curve. In the 3-D gore design, as a consequence, the shortening rate becomes a fundamental design parameter along with the geometric parameters of the gore. In view of this, we have carried out a series of numerical study of the lobed-pumpkin balloon with varying gore geometry as well as with varying shortening rate. The numerical simula-tions were carried out with a nonlinear finite element code incorporating the wrinkling effect. Numerical results show that there is a threshold value for the shortening rate beyond which the stresses in the balloon film increases disproportionately. We have also carried out quasi-static simulations of the inflation process of the lobed-pumpkin balloon, and have obtained asymmetric deformations when the balloon films are in uniaxial tension state.

  17. [The spectrum of histomorphological findings related to joint endoprosthetics].

    PubMed

    Morawietz, L; Krenn, V

    2014-11-01

    Approximately 230,000 total hip and 170,000 knee joint endoprostheses are implanted in Germany annually of which approximately 10% (i.e. 40,000 interventions per year) are cases of revision surgery. These interventions involve removal of a previously implanted prosthesis which has resulted in complaints and replacement with a new prosthesis. There are manifold reasons for revision surgery, the most common indication being so-called endoprosthesis loosening, which is subdivided into septic and aseptic loosening. Histomorphological studies revealed that periprosthetic tissue from endoprosthesis loosening can be classified into four types (I) wear-particle induced type, (II) infectious type, (III) combined type and (IV) fibrous type. Types I and IV represent aseptic loosening and types II and III septic loosening. Recently, the topic of implant allergy has emerged. The detection of cellular, mostly perivascular lymphocytic infiltrates is discussed as being a sign of an allergic tissue reaction. It has most frequently been observed in type I periprosthetic membranes with a dense load of metal wear, which occurs with metal-on-metal bearings. Apart from endoprosthesis loosening, arthrofibrosis is another complication of joint endoprosthetics and can cause pain and impaired function. Histopathologically, arthrofibrosis can be evaluated by a three-tiered grading system. Furthermore, bone pathologies, such as ossification, osteopenia or osteomyelitis can occur as complications of joint endoprosthetics. This review gives an overview of the whole spectrum of pathological findings in joint endoprosthetics and offers a comprehensive and standardized classification system for routine histopathological diagnostics.

  18. [Total hip endoprosthesis following resection arthroplasty].

    PubMed

    Engelbrecht, E; Siegel, A; Kappus, M

    1995-08-01

    From 1976 to December 1994, a total of 347 patients underwent implantation of a hip prosthesis at the ENDO-Klinik for treatment of an unsatisfactory condition following resection arthroplasty. From 1976 to 1987, 143 patients were treated and in 1989 the results obtained in these patients were analysed: 99 of them were available for a follow-up examination in 1989, and 64 for a further examination in 1995. In 130 cases infection had been the reason for joint resection. At the time of the prosthesis operation (1-20 years later) intraoperative biopsy revealed that infection was still present in 41 cases (31.5%). Only 15 of these infections had been detected preoperatively by joint aspiration. This shows that the value of resection arthroplasty as a method of treating periprosthetic infection is limited and lends support to the one-stage exchange operation, which is the method we prefer in cases of infected hip prostheses. The operative technique and preparation for implantation of the prosthesis are described, as are septic and aseptic complications and the measures that can be taken to treat them. In spite of the patients' generally poor initial condition and with due consideration for the further revision operations, the medium-term results finally obtained are poor in only 9%.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Winklehner, Anna, E-mail: anna.winklehner@usz.ch; Nguyen-Kim, Thi Dan Linh, E-mail: thidanlinh.nguyen@usz.ch; Pfammatter, Thomas, E-mail: thomas.pfammatter@usz.ch

    PurposeThis study was designed to evaluate retrospectively the long-term stent-graft patency after renovisceral revascularization with Viabahn Open Revascularization Technique (VORTEC) using computed tomography angiography (CTA) and magnetic resonance angiography (MRA).MethodsIn 34 patients (seven women; mean age 72 ± 8 years) with aortic aneurysm, 63 renovisceral vessels (i.e., 54 renal, nine visceral arteries) were revascularized with VORTEC between 2004 and 2009. All patients obtained a pre- and postinterventional CTA and at least one follow-up CTA or MRA after 6 or more months following intervention (median follow up: 43 months). Detection of bypass occlusion, bypass stenosis, infolding, stent-graft fractures and dislocations, and kidney shrinkage were notedmore » by two readers in consensus. Furthermore, mortality during follow-up was assessed using the medical report.ResultsDuring follow-up, 12.6 % of stent-grafts occluded. Cumulative patency rate was 95.2 ± 2.7 % at 12 months, 87.7 ± 4.4 % at 24 and 36 months, and 84.7 ± 5.2 % at 48, 60, 72, 84, and 89 months, respectively. Overall, 19 % of stent-grafts (12/63) developed bypass stenosis (<50 %, 10 stent-grafts; > 50 %, 2 stent-grafts), in one case stenosis (>70 %) was suspected to be hemodynamically significant. No secondary dislocation, no infolding of renovisceral stent-grafts, and no stent-graft fracture occurred. Kidney shrinkage occurred in nine patients, primarily in patients with an occluded Viabahn (n = 7). Eleven patients (32.3 %) died within the follow-up time period.ConclusionsIn long-term survivors after VORTEC cumulative patency rate remained high, and no stent-graft fractures or secondary dislocations occurred.« less

  20. Robotic artificial chordal replacement for repair of mitral valve prolapse.

    PubMed

    Brunsting, Louis A; Rankin, J Scott; Braly, Kimberly C; Binford, Robert S

    2009-07-01

    Artificial chordal replacement (ACR) has emerged as a superior method of mitral valve repair with excellent early and late efficacy. It is also ideal to combine with robotic techniques for correction of mitral prolapse, and this article presents a current method of robotic Gore-Tex ACR. Patients with isolated posterior leaflet prolapse are approached with the fourth-generation DaVinci robotic system and endoaortic balloon occlusion. A pledgetted anchor stitch is placed in a papillary muscle, and a 2-o Gore-Tex suture is passed through the anchor pledget. After full annuloplasty ring placement, the Gore-Tex suture is woven into the prolapsing segment and positioned temporarily with robotic forceps. Chordal length is then "adjusted" by lengthening or shortening the temporary knot over 1-cm increments as the valve is tested by injection of cold saline into the ventricle. After achieving good leaflet position and valve competence, the chord is tied permanently. The "adjustable" ACR procedure preserves leaflet surface area and produces a competent valve in the majority of patients. Postoperative transesophageal echo shows a large surface area of coaptation. Patient recovery is facilitated by the minimally invasive approach, while long-term stability of similar open ACR techniques have been excellent with a 2% to 3% failure rate over 10 years of follow-up. Robotic Gore-Tex ACR without leaflet resection is a reproducible procedure that simplifies mitral repair for prolapse. The outcomes observed in early robotic applications have been excellent. It is suggested that most patients with simple prolapse might validly be approached in this manner.

  1. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT - PERFORMANCE VERIFICATION OF THE W.L. GORE & ASSOCIATES GORE-SORBER SCREENING SURVEY

    EPA Science Inventory

    The U.S. Environmental Protection Agency (EPA) has created the Environmental Technology Verification Program (ETV) to facilitate the deployment of innovative or improved environmental technologies through performance verification and dissemination of information. The goal of the...

  2. Stress analysis of ribbon parachutes

    NASA Technical Reports Server (NTRS)

    Reynolds, D. T.; Mullins, W. M.

    1975-01-01

    An analytical method has been developed for determining the internal load distribution for ribbon parachutes subjected to known riser and aerodynamic forces. Finite elements with non-linear elastic properties represent the parachute structure. This method is an extension of the analysis previously developed by the authors and implemented in the digital computer program CANO. The present analysis accounts for the effect of vertical ribbons in the solution for canopy shape and stress distribution. Parametric results are presented which relate the canopy stress distribution to such factors as vertical ribbon strength, number of gores, and gore shape in a ribbon parachute.

  3. Endobag separation - an ominous sign after endovascular aneurysm sealing with the Nellix device.

    PubMed

    Tasleem, Sadia; Badri, Hassan; Ranjeet, Narlawar; Antoniou, George A

    2018-06-01

    Our report aims to alert physicians performing endovascular aneurysm sealing with the Nellix endoprosthesis to the risk of rupture when endobag separation is noticed on computed tomography. Endobag separation when observed with acute presentation of abdominal pain is an indicator of imminent rupture and prompt interventional treatment should be undertaken.

  4. Bioactive nanocomposite for chest-wall replacement: Cellular response in a murine model.

    PubMed

    Jungraithmayr, Wolfgang; Laube, Isabelle; Hild, Nora; Stark, Wendelin J; Mihic-Probst, Daniela; Weder, Walter; Buschmann, Johanna

    2014-07-01

    Chest-wall invading malignancies usually necessitate the resection of the respective part of the thoracic wall. Gore-Tex® is the material of choice that is traditionally used to repair thoracic defects. This material is well accepted by the recipient; however, though not rejected, it is an inert material and behaves like a 'foreign body' within the thoracic wall. By contrast, there are materials that have the potential to physiologically integrate into the host, and these materials are currently under in vitro and also in vivo investigation. These materials offer a gradual but complete biodegradation over time, and severe adverse inflammatory responses can be avoided. Here, we present a novel material that is a biodegradable nanocomposite based on poly-lactic-co-glycolic acid and amorphous calcium phosphate nanoparticles in comparison to the traditionally employed Gore-Tex® being the standard for chest-wall replacement. On a mouse model of thoracic wall resection, that resembles the technique and localization applied in humans, poly-lactic-co-glycolic acid and amorphous calcium phosphate nanoparticles and Gore-Tex® were implanted subcutaneously and additionally tested in a separate series as a chest-wall graft. After 1, 2, 4 and 8 weeks cell infiltration into the respective materials, inflammatory reactions as well as neo-vascularization (endothelial cells) were determined in six different zones. While Gore-Tex® allowed for cell infiltration only at the outer surface, electrospun poly-lactic-co-glycolic acid and amorphous calcium phosphate nanoparticles were completely penetrated by infiltrating cells. These cells were composed mainly by macrophages, with only 4% of giant cells and lymphocytes. Total macrophage count increased by time while the number of IL1-β-expressing macrophages decreased, indicating a protective state towards the graft. As such, poly-lactic-co-glycolic acid and amorphous calcium phosphate nanoparticles seem to develop ideal

  5. Failing left ventricle to ascending aorta conduit-Hybrid implantation of a melody valve and NuMed covered stent.

    PubMed

    Gössl, Mario; Johnson, Jonathan N; Hagler, Donald J

    2014-04-01

    We present the case of a 36-year-old woman with increasing shortness of breath, a new 3/4 diastolic murmur, and a complex history of LV outflow tract obstruction. She has undergone multiple surgeries including the replacement of her old LV apex to ascending aorta conduit with a 20-mm Gore-Tex tube graft, addition of a 24-mm homograft sutured between the conduit and the LV apex, and insertion of a 21-mm Freestyle porcine valve conduit between the Gore-Tex tube graft and allograft at age 23. The current assessment showed a failing Freestyle conduit prosthesis leading to left heart decompensation. Due to substantial surgical risk, the patient underwent successful implantation of a Melody valve into the Gore-Tex tube and exclusion of the failing Freestyle bioprosthesis with a NuMed CP stent in a hybrid procedure. The case nicely illustrates the collaborative potential of cardiovascular surgeons and interventional cardiologists in the new arena of a hybrid operating room. Complex hybrid procedures like the current one, especially those including percutaneous placements of valves, offer therapeutic options for patients that are otherwise too high risk for conventional open heart surgery. Copyright © 2013 Wiley Periodicals, Inc.

  6. Modified edge-to-edge technique for correction of congenital mitral regurgitation in infants and children.

    PubMed

    Zhang, Gang; Zhang, Fusheng; Zhu, Mei; Zhang, Wenlong; Fan, Quanxin; Zou, Chengwei; Wang, Anbiao

    2011-10-01

    Since 2008, 28 patients with congenital mitral regurgitation have undergone mitral valve repair with a modified edge-to-edge technique at our institution. The regurgitant mitral leaflet was sutured with a pledget-reinforced, horizontal mattress suture with No. 4-0 polypropylene on the ventricle side and a pledget-reinforced mattress suture with Gore-Tex sutures (W.L. Gore & Associates, Flagstaff, AZ) and Dacron pledgets (Chest, Shanghai) placed on the anterior and posterior annulus corresponding to the edge-to-edge suturing site. Early results are encouraging, but a longer follow-up is needed. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  7. Custom-made endoprostheses for the femoral amputation stump: an alternative to hip disarticulation in tumour surgery.

    PubMed

    Kalson, N S; Gikas, P D; Aston, W; Miles, J; Blunn, G; Pollock, R; Skinner, J; Briggs, T W R; Cannon, S R

    2010-08-01

    Disarticulation of the hip in patients with high-grade tumours in the upper thigh results in significant morbidity. In patients with no disease of the proximal soft tissue a femoral stump may be preserved, leaving a fulcrum for movement and weight-bearing. We reviewed nine patients in whom the oncological decision would normally be to disarticulate, but who were treated by implantation of an endoprosthesis in order to create a functioning femoral stump. The surgery was undertaken for chondrosarcoma in four patients, pleomorphic sarcoma in three, osteosarcoma in one and fibrous dysplasia in one. At follow-up at a mean of 80 months (34 to 132), seven patients were alive and free from disease, one had died from lung metastases and another from a myocardial infarction. The mean functional outcome assessment was 50 (musculoskeletal tumor society), 50 and 60 (physical and mental Short-form 36 scores). Implantation of an endoprosthesis into the stump in carefully selected patients allows fitting of an above-knee prosthesis and improves wellbeing and the functional outcome.

  8. Numerical study of the influence of the thickness and roughness of TiN coatings on their wear in scratch testing

    NASA Astrophysics Data System (ADS)

    Eremina, G. M.; Smolin, A. Yu.

    2017-12-01

    One of the mostly used and complicated surgical operations on large human joints is total hip replacement. An endoprosthesis is chosen individually for each person on the basis of his anatomical features and physical activity. However, such an important factor affecting the durability of an endoprosthesis as wear in the head-acetabular cup friction pair is still poorly understood, and it is taken into account only qualitatively. The determining role in wear belongs to the structure of the surface layers and coatings of the friction pair. The mechanical and structural characteristics of the coating largely depend on the method of its application. In this paper, to study the tribological characteristics of the coating material of the friction pair, we use computer simulation of scratch testing. The simulations are performed with the application of the method of movable cellular automata. The model specimens correspond to real coatings manufactured under different treatment conditions (deposition temperature and time). The analysis of the simulation results allows one to choose the optimal regime corresponding to the maximum hardness of coatings or adhesive strength.

  9. 75 FR 423 - Native American Housing Assistance and Self-Determination Reauthorization Act of 2008: Notice of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-05

    ..., Alaska. Carol Gore, President/CEO, Cook Inlet Housing Authority, Anchorage, Alaska. Blake Kazama..., Tahlequah, Oklahoma. Thomas McGeisey, Executive Director, Seminole Nation Housing Authority, Wewoka...

  10. Endovascular Treatment of Severely Calcified Femoropopliteal Lesions Using the "Pave-and-Crack" Technique: Technical Description and 12-Month Results.

    PubMed

    Dias-Neto, Marina; Matschuck, Manuela; Bausback, Yvonne; Banning-Eichenseher, Ursula; Steiner, Sabine; Branzan, Daniela; Staab, Holger; Varcoe, Ramon L; Scheinert, Dierk; Schmidt, Andrej

    2018-06-01

    To report midterm results of the "pave-and-crack" technique to facilitate safe and effective scaffolding of heavily calcified femoropopliteal lesions in preparation for delivery of a Supera interwoven stent. Data were collected retrospectively on 67 consecutive patients (mean age 71±8 years; 54 men) treated with this technique between November 2011 and February 2017 at a single center. A third (22/64, 34%) of the patients had critical limb ischemia (CLI). Most lesions were TASC D (52/67, 78%), and the majority were occlusions (61/66, 92%). The mean lesion length was 26.9±11.2 cm. Nearly two-thirds (40/64, 62%) had grade 4 calcification (Peripheral Arterial Calcium Scoring System). To prepare for Supera stenting, the most heavily calcified segments of the lesion were predilated aggressively to obliterate recoil. A Viabahn stent-graft was then implanted to "pave" the lesion and protect from vessel rupture as aggressive predilation continued until the calcified plaque was "cracked" before lining the entire lesion with a Supera stent. Patency and target lesion revascularization (TLR) rates were estimated using the Kaplan-Meier method. Procedural success was achieved in 100% and technical success (residual stenosis <30%) in 98% (66/67). The mean cumulative stent lengths were 16±9 cm for the Viabahn and 23±12 cm for the Supera. Only 2 complications occurred (distal embolization and access-site pseudoaneurysm). Two CLI patients died within 30 days, and 3 patients (all claudicants) underwent a TLR. Patients were followed for a mean 19±18 months, during which another 2 CLI patients died and 1 patient had a major amputation. One-year primary and secondary patency estimates were 79% and 91%, respectively; freedom from TLR was 85%. Despite severe lesion calcification, patients experienced high technical success and a safe and durable therapy at midterm follow-up with the femoropopliteal "pave-and-crack" technique.

  11. [Periodontal guided tissue regeneration with a rubber dam: short term clinical study].

    PubMed

    D'Archivio, D; Di Placido, G; Tumini, V; Paolantonio, M

    1998-03-01

    The guided regeneration of periodontal tissues demonstrated to represent a therapeutical technique with predictable results. It has been observed that different materials, used as regenerative membranes, offer very similar results. Unconventional materials too, like the rubber dam, seem to be useful in the guided tissues regeneration technique. The object of the present study has been to comparatively evaluate the effectiveness of Gore-Tex and rubber dam-made membranes in the therapy of intra-osseous periodontal defects. Six patients with two similar intra-osseous defects, participated in the study; one defect has been treated using, during the surgical intervention, a Gore-Tex membrane, while the other has received, a fragment of sterile rubber dam membranes. The principal clinical parameters of the periodontal health (probing depth -PD- and attachment loss -AL-) has been evaluated in both the defects before and 6 months after the periodontal surgery. The results have showed that there are not statistically significant differences (p > 0.05) in the healing of the intra-osseous defects treated by rubber dam or Gore-Tex. The conclusion is drawn that the rubber dam can represent a valid and cheap alternative to the materials traditionally used in the regenerative surgery of the periodontal tissues.

  12. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT; GROUNDWATER SAMPLING TECHNOLOGIES; W.L. GORE AND ASSOCIATES, INC., GORE-SORBER WATER QUALITY MONITORING

    EPA Science Inventory

    The U.S. Environmental Protection Agency (EPA) has created the Environmental Technology Verification Program (ETV) to facilitate the deployment of innovative or improved environmental technologies through performance verification and dissemination of information. The goal of the...

  13. Seven Democratic Presidential Candidates Debate Educational Issues.

    ERIC Educational Resources Information Center

    Equity and Excellence, 1988

    1988-01-01

    Provides the transcript of a debate on educational issues among Democratic presidential candidates Paul Simon, Albert Gore, Joseph Biden, Jesse Jackson, Bruce Babbitt, Richard Gephart, and Michael Dukakis. (BJV)

  14. U.S. Presidential Candidate camps debate sciences issues

    NASA Astrophysics Data System (ADS)

    Showstack, Randy

    2000-10-01

    While budget surpluses, social security, and tax cut proposals have been major focuses during the U.S. presidential campaign between Texas Governor George W Bush and Vice President Al Gore, the candidates also have staked out a number of important issues related to Earth sciences and the environment. Two recent debates between representatives of the Bush and Gore camps have helped to clarify these positions. The Washington Science Policy Alliance presented a candidates forum on science and technology policy on October 5 at the American Association for the Advancement of Science (AAAS), in Washington, D.C. On September 26, the non-profit National Environmental Policy Institute (NEPI) held a debate on presidential politics and the environment at the National Press Club, also in Washington, D.C.

  15. Permanent stenting in "unextractable" common bile duct stones in high risk patients. A prospective randomized study comparing two different stents.

    PubMed

    Pisello, Franco; Geraci, Girolamo; Li Volsi, Francesco; Modica, Giuseppe; Sciumè, Carmelo

    2008-11-01

    Endoscopic sphincterotomy (ES) and stone extraction is the treatment of choice for bile duct stones. Therefore, if ES and conventional stone extraction fail, further treatment is mandatory. Insertion of a biliary endoprosthesis is an effective option. We treated 30 high-risk patients (17 women and 13 men, mean age 82 years) affected by difficult common bile duct stones. The patients were randomly assigned preoperatively using closed envelopes (blind randomization) into two groups to receive insertion of polyethylene or hydrophilic hydromer-coated polyurethane stent, respectively. Follow-up was achieved by contacting referring physicians and patient's relatives. Biliary drainage was established in all patients. Early minor complications occurred in 28%. In all these patients, the stent was a definitive measure. Median follow-up was 38 months. Late complications occurred in 34%. Cholangitis was the most frequent. During follow up, 11 patients died, two as result of a biliary-related cause. No statistically significant difference was observed on different stents patency. Endoprosthesis insertion as a permanent therapy is an effective alternative to surgery or dissolution therapy. Therefore, biliary stenting should preferably be restricted to high-risk patients unfit for operative treatment and with a short life expectancy.

  16. Esophagorespiratory fistulas of tumorous origin. Non-operative management of 264 cases in a 20-year period.

    PubMed

    Balazs, Akos; Kupcsulik, Peter K; Galambos, Zoltan

    2008-11-01

    Esophagorespiratory fistulas developing from malignant tumors have serious complications by maintaining continuous airway contamination. The objective was to reveal the incidence, causes and characteristics of fistula formation and to examine the possibilities and efficiency of the treatment. In a single-center study between 1984 and 2004, the data of 2113 patients with tumorous esophageal stenosis were analyzed. Esophagorespiratory fistulas were detected in 264 cases (12.5%). Successful esophageal intubation, stent correction or replacement was performed in 188 cases, while there was one lethal complication. Twenty-seven patients had an intervention for nutritional support: 25 gastrostomies, 1 jejunostomy and 1 percutaneous endoscopic gastrostomy. The mean survival period of all patients was 2.8 months; patients with implanted endoprosthesis 3.4 months; with nutritional support 1.1 months and with only supportive therapy 1.3 months, respectively. The differences between the endoprosthesis implanted group and the other two groups were significant (p<0.001). By sealing the fistula, a successful endoscopic esophageal intubation ends the severe respiratory contamination and the inability to swallow, improving the quality of life and survival period. After the procedure, it is the malignant tumor and not the fistula that determines the future of the patient.

  17. Effect of cup inclination on predicted contact stress-induced volumetric wear in total hip replacement.

    PubMed

    Rijavec, B; Košak, R; Daniel, M; Kralj-Iglič, V; Dolinar, D

    2015-01-01

    In order to increase the lifetime of the total hip endoprosthesis, it is necessary to understand mechanisms leading to its failure. In this work, we address volumetric wear of the artificial cup, in particular the effect of its inclination with respect to the vertical. Volumetric wear was calculated by using mathematical models for resultant hip force, contact stress and penetration of the prosthesis head into the cup. Relevance of the dependence of volumetric wear on inclination of the cup (its abduction angle ϑA) was assessed by the results of 95 hips with implanted endoprosthesis. Geometrical parameters obtained from standard antero-posterior radiographs were taken as input data. Volumetric wear decreases with increasing cup abduction angle ϑA. The correlation within the population of 95 hips was statistically significant (P = 0.006). Large cup abduction angle minimises predicted volumetric wear but may increase the risk for dislocation of the artificial head from the cup in the one-legged stance. Cup abduction angle and direction of the resultant hip force may compensate each other to achieve optimal position of the cup with respect to wear and dislocation in the one-legged stance for a particular patient.

  18. Chronic Contained Rupture of an Abdominal Aortic Aneurysm: From Diagnosis to Endovascular Resolution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gandini, Roberto, E-mail: marcello.chiocchi@fastwebnet.it; Chiocchi, Marcello; Maresca, Luciano

    2008-07-15

    A male patient, 69 years old, presented with fever, leucocytosis, and persistent low back pain; he also had an abdominal aortic aneurysm (AAA), as previously diagnosed by Doppler UltraSound (US), and was admitted to our hospital. On multislice computed tomography (msCT), a large abdominal mass having no definite border and involving the aorta and both of the psoas muscles was seen. This mass involved the forth-lumbar vertebra with lysis, thus simulating AAA rupture into a paraspinal collection; it was initially considered a paraspinal abscess. After magnetic resonance imaging examination and culture of the fluid aspirated from the mass, no infectivemore » organisms were found; therefore, a diagnosisof chronically contained AAA rupture was made, and an aortic endoprosthesis was subsequently implanted. The patient was discharged with decreased lumbar pain. At 12-month follow-up, no evidence of leakage was observed. To our knowledge, this is the first case of endoprosthesis implantation in a patient, who was a poor candidate for surgical intervention due to renal failure, leucocytosis and high fever, having a chronically contained AAA ruptured simulatingspodilodiscitis abscess. Appropriate diagnosis and therapy resolved potentially crippling pathology and avoided surgical graft-related complications.« less

  19. Development of tailorable advanced blanket insulation for advanced space transportation systems

    NASA Technical Reports Server (NTRS)

    Calamito, Dominic P.

    1987-01-01

    Two items of Tailorable Advanced Blanket Insulation (TABI) for Advanced Space Transportation Systems were produced. The first consisted of flat panels made from integrally woven, 3-D fluted core having parallel fabric faces and connecting ribs of Nicalon silicon carbide yarns. The triangular cross section of the flutes were filled with mandrels of processed Q-Fiber Felt. Forty panels were prepared with only minimal problems, mostly resulting from the unavailability of insulation with the proper density. Rigidizing the fluted fabric prior to inserting the insulation reduced the production time. The procedures for producing the fabric, insulation mandrels, and TABI panels are described. The second item was an effort to determine the feasibility of producing contoured TABI shapes from gores cut from flat, insulated fluted core panels. Two gores of integrally woven fluted core and single ply fabric (ICAS) were insulated and joined into a large spherical shape employing a tadpole insulator at the mating edges. The fluted core segment of each ICAS consisted of an Astroquartz face fabric and Nicalon face and rib fabrics, while the single ply fabric segment was Nicalon. Further development will be required. The success of fabricating this assembly indicates that this concept may be feasible for certain types of space insulation requirements. The procedures developed for weaving the ICAS, joining the gores, and coating certain areas of the fabrics are presented.

  20. Preface to RIGiM 2009

    NASA Astrophysics Data System (ADS)

    Rolland, Colette; Yu, Eric; Salinesi, Camille; Castro, Jaelson

    The use of intentional concepts, the notion of "goal" in particular, has been prominent in recent approaches to requirement engineering (RE). Goal-oriented frameworks and methods for requirements engineering (GORE) have been keynote topics in requirements engineering, conceptual modelling, and more generally in software engineering. What are the conceptual modelling foundations in these approaches? RIGiM (Requirements Intentions and Goals in Conceptual Modelling) aims to provide a forum for discussing the interplay between requirements engineering and conceptual modelling, and in particular, to investigate how goal- and intention-driven approaches help in conceptualising purposeful systems. What are the fundamental objectives and premises of requirements engineering and conceptual modelling respectively, and how can they complement each other? What are the demands on conceptual modelling from the standpoint of requirements engineering? What conceptual modelling techniques can be further taken advantage of in requirements engineering? What are the upcoming modelling challenges and issues in GORE? What are the unresolved open questions? What lessons are there to be learnt from industrial experiences? What empirical data are there to support the cost-benefit analysis when adopting GORE methods? Are there application domains or types of project settings for which goals and intentional approaches are particularly suitable or not suitable? What degree of formalization and automation, or interactivity is feasible and appropriate for what types of participants during requirements engineering?

  1. Geology of the Lachesis Tessera V18 Quadrangle, Venus

    NASA Astrophysics Data System (ADS)

    McGowan, E. M.; McGill, G. E.

    2011-03-01

    Summary of the geology of the Lachesis Tessera, focusing on a linear grouping of structural features that includes Breksta Linea. This grouping includes an unnamed corona that is obscured by a large gore.

  2. Most Recent Sampling Results for Annex III Building

    EPA Pesticide Factsheets

    Contains email from Scott Miller, US EPA to Scott Kramer. Subject: Most Recent Sampling Results for Annex III Building. (2:52 PM) and Gore(TM) Surveys Analytical Results U.S. Geological Survey, Montgomery, AL.

  3. Geologic map of the Vail West quadrangle, Eagle County, Colorado

    USGS Publications Warehouse

    Scott, Robert B.; Lidke, David J.; Grunwald, Daniel J.

    2002-01-01

    This new 1:24,000-scale geologic map of the Vail West 7.5' quadrangle, as part of the USGS Western Colorado I-70 Corridor Cooperative Geologic Mapping Project, provides new interpretations of the stratigraphy, structure, and geologic hazards in the area on the southwest flank of the Gore Range. Bedrock strata include Miocene tuffaceous sedimentary rocks, Mesozoic and upper Paleozoic sedimentary rocks, and undivided Early(?) Proterozoic metasedimentary and igneous rocks. Tuffaceous rocks are found in fault-tilted blocks. Only small outliers of the Dakota Sandstone, Morrison Formation, Entrada Sandstone, and Chinle Formation exist above the redbeds of the Permian-Pennsylvanian Maroon Formation and Pennsylvanian Minturn Formation, which were derived during erosion of the Ancestral Front Range east of the Gore fault zone. In the southwestern area of the map, the proximal Minturn facies change to distal Eagle Valley Formation and the Eagle Valley Evaporite basin facies. The Jacque Mountain Limestone Member, previously defined as the top of the Minturn Formation, cannot be traced to the facies change to the southwest. Abundant surficial deposits include Pinedale and Bull Lake Tills, periglacial deposits, earth-flow deposits, common diamicton deposits, common Quaternary landslide deposits, and an extensive, possibly late Pliocene landslide deposit. Landscaping has so extensively modified the land surface in the town of Vail that a modified land-surface unit was created to represent the surface unit. Laramide movement renewed activity along the Gore fault zone, producing a series of northwest-trending open anticlines and synclines in Paleozoic and Mesozoic strata, parallel to the trend of the fault zone. Tertiary down-to-the-northeast normal faults are evident and are parallel to similar faults in both the Gore Range and the Blue River valley to the northeast; presumably these are related to extensional deformation that occurred during formation of the northern end of the

  4. A Validated Set of MIDAS V5 Task Network Model Scenarios to Evaluate Nextgen Closely Spaced Parallel Operations Concepts

    NASA Technical Reports Server (NTRS)

    Gore, Brian Francis; Hooey, Becky Lee; Haan, Nancy; Socash, Connie; Mahlstedt, Eric; Foyle, David C.

    2013-01-01

    The Closely Spaced Parallel Operations (CSPO) scenario is a complex, human performance model scenario that tested alternate operator roles and responsibilities to a series of off-nominal operations on approach and landing (see Gore, Hooey, Mahlstedt, Foyle, 2013). The model links together the procedures, equipment, crewstation, and external environment to produce predictions of operator performance in response to Next Generation system designs, like those expected in the National Airspaces NextGen concepts. The task analysis that is contained in the present report comes from the task analysis window in the MIDAS software. These tasks link definitions and states for equipment components, environmental features as well as operational contexts. The current task analysis culminated in 3300 tasks that included over 1000 Subject Matter Expert (SME)-vetted, re-usable procedural sets for three critical phases of flight; the Descent, Approach, and Land procedural sets (see Gore et al., 2011 for a description of the development of the tasks included in the model; Gore, Hooey, Mahlstedt, Foyle, 2013 for a description of the model, and its results; Hooey, Gore, Mahlstedt, Foyle, 2013 for a description of the guidelines that were generated from the models results; Gore, Hooey, Foyle, 2012 for a description of the models implementation and its settings). The rollout, after landing checks, taxi to gate and arrive at gate illustrated in Figure 1 were not used in the approach and divert scenarios exercised. The other networks in Figure 1 set up appropriate context settings for the flight deck.The current report presents the models task decomposition from the tophighest level and decomposes it to finer-grained levels. The first task that is completed by the model is to set all of the initial settings for the scenario runs included in the model (network 75 in Figure 1). This initialization process also resets the CAD graphic files contained with MIDAS, as well as the embedded

  5. Auxetic coronary stent endoprosthesis: fabrication and structural analysis.

    PubMed

    Amin, Faisal; Ali, Murtaza Najabat; Ansari, Umar; Mir, Mariam; Minhas, Muhammad Asim; Shahid, Wakeel

    2015-07-04

    Cardiovascular heart disease is one of the leading health issues in the present era and requires considerable health care resources to prevent it. The present study was focused on the development of a new coronary stent based on novel auxetic geometry which enables the stent to exhibit a negative Poisson's ratio. Commercially available coronary stents have isotropic properties, whereas the vascular system of the body shows anisotropic characteristics. This results in a mismatch between anisotropic-isotropic properties of the stent and arterial wall, and this in turn is not favorable for mechanical adhesion of the commercially available coronary stents with the arterial wall. It is believed that an auxetic coronary stent with inherent anisotropic mechanical properties and negative Poisson's ratio will have good mechanical adhesion with the arterial wall. The auxetic design was obtained via laser cutting, and surface treatment was performed with acid pickling and electropolishing, followed by an annealing process. In vitro mechanical analysis was performed to analyze the mechanical performance of the auxetic coronary stent. Scanning electronic microscopy (SEM) was used to determine the effects of fabrication processes on the topography of the auxetic stent. The elastic recoil (3.3%) of the in vitro mechanical analysis showed that the auxetic stent design effectively maintained the luminal patency of the coronary artery. Also, the auxetic coronary stent showed no foreshortening, therefore it avoids the problem of stent migration, by expanding in both the radial and longitudinal directions. By virtue of its synclastic behavior, the auxetic stent bulges outward when it is radially expanded through an inflated balloon.

  6. The Ring Sculptor

    NASA Image and Video Library

    2006-09-08

    Prometheus zooms across the Cassini spacecraft field of view, attended by faint streamers and deep gores in the F ring. This movie sequence of five images shows the F ring shepherd moon shaping the ring inner edge

  7. Structural-Geometric Functionalization of the Additively Manufactured Prototype of Biomimetic Multispiked Connecting Ti-Alloy Scaffold for Entirely Noncemented Resurfacing Arthroplasty Endoprostheses.

    PubMed

    Uklejewski, Ryszard; Winiecki, Mariusz; Rogala, Piotr; Patalas, Adam

    2017-01-01

    The multispiked connecting scaffold (MSC-Scaffold) prototype, inspired by the biological system of anchorage of the articular cartilage in the periarticular trabecular bone by means of subchondral bone interdigitations, is the essential innovation in fixation of the bone in resurfacing arthroplasty (RA) endoprostheses. The biomimetic MSC-Scaffold, due to its complex geometric structure, can be manufactured only using additive technology, for example, selective laser melting (SLM). The major purpose of this work is determination of constructional possibilities for the structural-geometric functionalization of SLM-manufactured MSC-Scaffold prototype, compensating the reduced ability-due to the SLM technological limitations-to accommodate the ingrowing bone filling the interspike space of the prototype, which is important for the prototype bioengineering design. Confocal microscopy scanning of components of the SLM-manufactured prototype of total hip resurfacing arthroplasty (THRA) endoprosthesis with the MSC-Scaffold was performed. It was followed by the geometric measurements of a variety of specimens designed as the fragments of the MSC-Scaffold of both THRA endoprosthesis components. The reduced ability to accommodate the ingrowing bone tissue in the SLM-manufactured prototypes versus that in the corresponding CAD models has been quantitatively determined. Obtained results enabled to establish a way of compensatory structural-geometric functionalization, allowing the MSC-Scaffold adequate redesigning and manufacturing in additive SLM technology.

  8. Technology Approach: DoD Versus Boeing (A Comparative Study)

    DTIC Science & Technology

    2016-01-01

    the American public continues to demand that its gov - ernment become more efficient, prompting Vice President Al Gore to initiate a National...new world dictionary, Ohio: William Collins. Henderson, B. W. (1990, December). NASA research aircraft demonstrates solutions to powered-lift

  9. 77 FR 14369 - Granting of Request for Early Termination of the Waiting Period Under the Premerger Notification...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-09

    ... Partners HI, L.P.; The Pep Boys- Manny, Moe & Jack; Gores Capital Partners III, L.P. 02/23/2012 20120338 G.... Donald S. Clark, Secretary. [FR Doc. 2012-5606 Filed 3-8-12; 8:45 a.m.] BILLING CODE 6750-01-M ...

  10. Judging the goring ox: retribution directed toward animals.

    PubMed

    Goodwin, Geoffrey P; Benforado, Adam

    2015-04-01

    Prior research on the psychology of retribution is complicated by the difficulty of separating retributive and general deterrence motives when studying human offenders (Study 1). We isolate retribution by investigating judgments about punishing animals, which allows us to remove general deterrence from consideration. Studies 2 and 3 document a "victim identity" effect, such that the greater the perceived loss from a violent animal attack, the greater the belief that the culprit deserves to be killed. Study 3 documents a "targeted punishment" effect, such that the responsive killing of the actual "guilty" culprit is seen as more deserved than the killing of an almost identical yet "innocent" animal from the same species. Studies 4 and 5 extend both effects to participants' acceptance of inflicting pain and suffering on the offending animal at the time of its death, and show that both effects are mediated by measures of retributive sentiment, and not by consequentialist concerns. Copyright © 2014 Cognitive Science Society, Inc.

  11. Periprosthetic joint infections in modular endoprostheses of the lower extremities: a retrospective observational study in 101 patients.

    PubMed

    Zajonz, Dirk; Zieme, Almut; Prietzel, Torsten; Moche, Michael; Tiepoldt, Solveig; Roth, Andreas; Josten, Christoph; von Salis-Soglio, Georg Freiherr; Heyde, Christoph-E; Ghanem, Mohamed

    2016-01-01

    Modular mega-endoprosthesis systems are used to bridge very large bone defects and have become a widespread method in orthopaedic surgery for the treatment of tumours and revision arthroplasty. However, the indications for the use of modular mega-endoprostheses must be carefully considered. Implanting modular endoprostheses requires major, complication-prone surgery in which the limited salvage procedures should always be borne in mind. The management of periprosthetic infection is particularly difficult and beset with problems. Given this, the present study was designed to gauge the significance of periprosthetic infections in connection with modular mega-implants in the lower extremities among our own patients. Patients who had been fitted with modular endoprosthesis on a lower extremity at our department between September 1994 and December 2011 were examined retrospectively. A total of 101 patients with 114 modular prostheses were identified. Comprising 30 men (29.7 %) and 71 women (70.3 %), their average age at the time of surgery was 67 years (18-92 years). The average follow-up period was 27 months (5 months and 2 weeks to 14 years and 11 months) and the drop-out rate was about 8.8 %. Altogether, there were 19 (17.7 %) endoprosthesis infections: 3 early infections and 16 late or delayed infections. The pathogen spectrum was dominated by coagulase-negative staphylococci (36 %) and Staphylococcus aureus (16 %), including 26 % multi-resistant pathogens. Reinfection occurred in 37 % of cases of infection. Tumours were followed by significantly fewer infections than the other indications. Infections were twice as likely to occur after previous surgery. In our findings modular endoprostheses (18 %) are much more susceptible to infection than primary endoprostheses (0.5-2,5 %). Infection is the most common complication alongside the dislocation of proximal femur endoprostheses. Consistent, radical surgery is essential - although even with an adequate

  12. The Brooks Act, Is it Relevant Today?

    DTIC Science & Technology

    1994-06-01

    Publishing Company, 1990. 7. Fla=., Kenneth. Creatina The ComDuter. Washington, D.C.: The Brookings Institution, 1988. 8. Gilchrist, Bruce, & Wessel...Milton R. Reaulation of the Computer Industry. Montvale: AFIPS Press, 1972. 9. Gore, Al. Creatina A Government That Works Better & Cost Less: Renort

  13. Adolescents' Enjoyment of Graphic Horror: Effects of Viewers' Attitudes and Portrayals of Victim.

    ERIC Educational Resources Information Center

    Oliver, Mary Beth

    1993-01-01

    Finds that more permissive sexual attitudes and lower levels of punitiveness were associated with adolescents' greater enjoyment of "slasher films." Shows that traditional attitudes toward females' sexuality were positively associated with gore-watching motivations and with greater enjoyment of previews featuring female victims. (SR)

  14. [Histopathological diagnostic work-up of joint endoprosthesis-associated pathologies].

    PubMed

    Krenn, V; Perino, G; Krenn, V T; Wienert, S; Saberi, D; Hügle, T; Hopf, F; Huber, M

    2016-05-01

    Increasing classes of joint implants and the combination of materials results in increased and wear-associated pathologies. According to the revised consensus classification, the following types can be recognized at conventional histological examination: Type I, particle-induced type; Type II, infection type; Type III, combination type; Type IV, indifferent type; Type V arthrofibrotic type; Type VI, allergic/immunological/toxic adverse reactions and Type VII, bone pathologies. Wear particles are histopathologically characterized according to the Krenn particle algorithm which focuses on a descriptive identification of wear particles and the differentiation of other nonwear-related particles. Type VII is considered histologically when there is evidence of a perivascular/interstitial lymphocytic CD20- and CD3-positive infiltrate, presence of mast cells and eosinophils, and tissue necrosis/infarction associated with implant wear material. Since wear particle-induced toxicity cannot be differentiated with certainty from hypersensitivity/allergic reaction on histological examination, immunological-allergological and clinical data should be used as supplementary criteria for the differential diagnosis. Tissue sampling should be performed from periprosthetic soft tissue with location mapping and when feasible also from bone tissue. Additional information regarding the type of implant and clinical, radiological, immunological, and microbiology data should be available to the pathologist. Further immunohistochemical studies are recommended in the following settings: infection (CD15, CD20, CD68); prosthesis-associated arthrofibrosis (β‑catenin); allergic/immunologic/toxic adverse reactions (CD20, CD3, CD4, CD8, CD117 and for T‑cell characterization T‑bet, GATA-3, and FOXP3).

  15. MID-ATLANTIC REGIONAL ASSESSMENT: REPORT OF A WORKSHOP ON CLIMATE CHANGE IMPACTS IN THE MID-ATLANTIC REGION

    EPA Science Inventory

    Vice President Gore and the Office of Science and Technology Policy (OSTP) recognized that global change will be felt differently by people depending on where they live and encouraged the U.S. Global Change Research Program (USGCRP) to create a series of workshops in 1997. The p...

  16. DOS/Russian - US program overview

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pifer, M.L.

    1996-04-01

    This paper describes the organization and describes the objectives for the science and technology agreements between the U.S.A. and Russia. The Gore-Chernomyrdin Commission objectives and the Civilian Research and the Development Foundation for the Independent States of the former Soviet Union (CRDF) are discussed.

  17. Adolescents' Motivations for Viewing Graphic Horror.

    ERIC Educational Resources Information Center

    Johnston, Deirdre D.

    1995-01-01

    Identifies four motivations adolescents report for viewing graphic horror films: gore watching, thrill watching, independent watching, and problem watching. Argues that viewing motivations are predictors of responses to graphic horror. Finds that viewing motivations were related to viewers' cognitive and affective responses and a tendency to…

  18. Preservice Physical Educators' Perspectives of Sport Education

    ERIC Educational Resources Information Center

    James, Alisa R.; Collier, Douglas; Brusseau, Tim

    2015-01-01

    Although many researchers have investigated sport education (SE) as a curriculum model at different educational levels (Bennett & Hastie, 1997; MacPhail, Gorely, Kirk, & Kinchin, 2008; MacPhail & Kinchin, 2004; Spittle & Byrne, 2009), there has been limited research on preservice physical education (PE) teachers' perceptions of SE.…

  19. Myth and Multiple Readings in Environmental Rhetoric: The Case of "An Inconvenient Truth"

    ERIC Educational Resources Information Center

    Rosteck, Thomas; Frentz, Thomas S.

    2009-01-01

    Contesting interpretations of "An Inconvenient Truth" that treat it as political jeremiad, autobiography, or science documentary, we contextualize the film within Joseph Campbell's monomyth and argue that its rhetorical efficacy arises in part because Al Gore's personal transformation animates the documentary footage with jeremiad advocacy. In…

  20. Deeper Insight into Fluorescence--Excitation of Molecules by Light

    NASA Astrophysics Data System (ADS)

    Wahab, M. Farooq; Gore, Gordon R.

    2013-05-01

    In a recent issue of TPT, Gordon Gore made interesting observations about the red or yellow fluorescence when laser beams are passed through olive oil. With the excellent visuals contained in that article, we present a pictorial explanation of the questions that were raised in Ref 1.

  1. [Experiences with the condition of resection of the hip joint following removal of the alloarthroplastic implantate (author's transl)].

    PubMed

    Reflor, H J; Wirth, C J; Schreiner, B

    1979-10-01

    30 patients whose total endoprosthesis of the hip joint had been removed without any replacement, thus creating a so-called state of secondary resection, were followed up 6 months to 6 years after the operation. It was found that in almost two-thirds of the cases a subjective feeling of improved mobility was reported. The objective findings consisted in restrictions of the total rotation, abduction and adduction of 1/3 rd of the normal extent of mobility. An average value of 74.7 degrees was recorded for flexion. 28 patients stated that their walking performance was satisfactory to very good when using a walking-stick as support. More than three-quarters of the patients questioned stated their pain had been positively influenced by the creation of the state of secondary resection. Another objective finding was a difference between the length of the legs amounting to 4.2 cm on the average. We could prove the existence of a relationship between the difference in leg length and the roentgenologically visualised supporting of the resection area of the coxal end of the femur at the lateral pelvis. Since all the patients with the exception of two could resume their customary daily routine activities, the state of secondary resection after unsuccessful total endoprosthesis of the hip joint must be considered a reasonably acceptable alternative.

  2. Structural-Geometric Functionalization of the Additively Manufactured Prototype of Biomimetic Multispiked Connecting Ti-Alloy Scaffold for Entirely Noncemented Resurfacing Arthroplasty Endoprostheses

    PubMed Central

    Rogala, Piotr; Patalas, Adam

    2017-01-01

    The multispiked connecting scaffold (MSC-Scaffold) prototype, inspired by the biological system of anchorage of the articular cartilage in the periarticular trabecular bone by means of subchondral bone interdigitations, is the essential innovation in fixation of the bone in resurfacing arthroplasty (RA) endoprostheses. The biomimetic MSC‐Scaffold, due to its complex geometric structure, can be manufactured only using additive technology, for example, selective laser melting (SLM). The major purpose of this work is determination of constructional possibilities for the structural-geometric functionalization of SLM‐manufactured MSC‐Scaffold prototype, compensating the reduced ability—due to the SLM technological limitations—to accommodate the ingrowing bone filling the interspike space of the prototype, which is important for the prototype bioengineering design. Confocal microscopy scanning of components of the SLM‐manufactured prototype of total hip resurfacing arthroplasty (THRA) endoprosthesis with the MSC‐Scaffold was performed. It was followed by the geometric measurements of a variety of specimens designed as the fragments of the MSC-Scaffold of both THRA endoprosthesis components. The reduced ability to accommodate the ingrowing bone tissue in the SLM‐manufactured prototypes versus that in the corresponding CAD models has been quantitatively determined. Obtained results enabled to establish a way of compensatory structural‐geometric functionalization, allowing the MSC‐Scaffold adequate redesigning and manufacturing in additive SLM technology. PMID:28785159

  3. What is the emotional acceptance after limb salvage with an expandable prosthesis?

    PubMed

    Henderson, Eric R; Pepper, Andrew M; Marulanda, German A; Millard, Justin D; Letson, G Douglas

    2010-11-01

    Limb preservation surgery for extremity sarcomas offers the promise of improved function and cosmesis over amputation. Application of limb salvage surgery for pediatric patients with expandable metallic endoprostheses is gaining acceptance. The few studies reporting these devices have focused on functional outcomes; one has addressed quality of life. We asked the following questions: (1) how happy are these patients; (2) how do these patients perceive their bodies; (3) do these children have difficulty with social interactions; and (4) how satisfied are patients and their parents with their outcomes? We retrospectively identified and contacted 26 living patients who underwent limb salvage with an expandable device. The Pediatric Outcomes Data Collection Instrument was administered to 15 of the 26 families. Attention was paid to the happiness domain of the Pediatric Outcomes Data Collection Instrument and specific answers within this domain were reported. Children who received limb salvage with an expandable endoprosthesis showed high emotional satisfaction with their outcome. Overall patients reported excellent perceptions of body image and physical attractiveness. Most patients reported frequent social interactions with their peers and no difficulty with making new friends. Although this study has a limited number of subjects and no control group, the data correlate with previously scores and indicate a high degree of emotional acceptance after limb salvage with an expandable endoprosthesis in a pediatric population.

  4. Next-generation Digital Earth

    PubMed Central

    Goodchild, Michael F.; Guo, Huadong; Annoni, Alessandro; Bian, Ling; de Bie, Kees; Campbell, Frederick; Craglia, Max; Ehlers, Manfred; van Genderen, John; Jackson, Davina; Lewis, Anthony J.; Pesaresi, Martino; Remetey-Fülöpp, Gábor; Simpson, Richard; Skidmore, Andrew; Wang, Changlin; Woodgate, Peter

    2012-01-01

    A speech of then-Vice President Al Gore in 1998 created a vision for a Digital Earth, and played a role in stimulating the development of a first generation of virtual globes, typified by Google Earth, that achieved many but not all the elements of this vision. The technical achievements of Google Earth, and the functionality of this first generation of virtual globes, are reviewed against the Gore vision. Meanwhile, developments in technology continue, the era of “big data” has arrived, the general public is more and more engaged with technology through citizen science and crowd-sourcing, and advances have been made in our scientific understanding of the Earth system. However, although Google Earth stimulated progress in communicating the results of science, there continue to be substantial barriers in the public’s access to science. All these factors prompt a reexamination of the initial vision of Digital Earth, and a discussion of the major elements that should be part of a next generation. PMID:22723346

  5. Next-generation Digital Earth.

    PubMed

    Goodchild, Michael F; Guo, Huadong; Annoni, Alessandro; Bian, Ling; de Bie, Kees; Campbell, Frederick; Craglia, Max; Ehlers, Manfred; van Genderen, John; Jackson, Davina; Lewis, Anthony J; Pesaresi, Martino; Remetey-Fülöpp, Gábor; Simpson, Richard; Skidmore, Andrew; Wang, Changlin; Woodgate, Peter

    2012-07-10

    A speech of then-Vice President Al Gore in 1998 created a vision for a Digital Earth, and played a role in stimulating the development of a first generation of virtual globes, typified by Google Earth, that achieved many but not all the elements of this vision. The technical achievements of Google Earth, and the functionality of this first generation of virtual globes, are reviewed against the Gore vision. Meanwhile, developments in technology continue, the era of "big data" has arrived, the general public is more and more engaged with technology through citizen science and crowd-sourcing, and advances have been made in our scientific understanding of the Earth system. However, although Google Earth stimulated progress in communicating the results of science, there continue to be substantial barriers in the public's access to science. All these factors prompt a reexamination of the initial vision of Digital Earth, and a discussion of the major elements that should be part of a next generation.

  6. Studies of cartilaginous tissue using Raman spectroscopy method

    NASA Astrophysics Data System (ADS)

    Timchenko, Pavel E.; Timchenko, Elena V.; Volova, Larisa T.; Dolgyshkin, Dmitry A.; Markova, Maria D.; Kylabyhova, A. Y.; Kornilin, Dmitriy V.

    2016-10-01

    The work presents the results of studies of samples of human articular surface of the knee joint, obtained by Raman spectroscopy implementedduring endoprosthesis replacement surgery . The main spectral characteristics of articular surface areas with varying degrees of cartilage damage were detected at 956 cm-1, 1066 cm-1 wavenumbers, corresponding to phosphate and carbonate, and at 1660 cm-1, 1271 cm-1 wavenumbers, corresponding to amide I and amide III. Criteria allowing to identify the degree of articular hyaline cartilage damage were introduced.

  7. Community Update, 1999.

    ERIC Educational Resources Information Center

    Anderson, Julie, Ed.

    1999-01-01

    This document consists of nine issues (covering January through December 1999) of the newsletter "Community Update," containing articles on community and family involvement in education. Article topics include: new programs to help students prepare for college early; Vice President Al Gore announced the first-ever national Hispanic Education…

  8. A History of Educational Facilities Laboratories (EFL)

    ERIC Educational Resources Information Center

    Marks, Judy

    2009-01-01

    The Educational Facilities Laboratories (EFL), an independent research organization established by the Ford Foundation, opened its doors in 1958 under the direction of Harold B. Gores, a distinguished educator. Its purpose was to help schools and colleges maximize the quality and utility of their facilities, stimulate research, and disseminate…

  9. Voting Rights Issues in the New Millennium.

    ERIC Educational Resources Information Center

    Ryan, John Paul, Ed.

    2001-01-01

    This publication examines ways to teach about law in the liberal arts. This issue focuses on future voting rights issues by exploring the 2000 presidential election. Articles included are: "Voting Rights in the New Millennium" (Jason F. Kirksey); "Legal and Political Lessons from 'Bush v. Gore'" (David Schultz); "The…

  10. Review and Oversight of the 1998 Reading Results of the National Assessment of Educational Progress (NAEP)--The Nation's Report Card. Hearing before the Subcommittee on Oversight and Investigations of the Committee on Education and the Workforce. United States House of Representatives, One Hundred Sixth Congress, First Session.

    ERIC Educational Resources Information Center

    Congress of the U.S., Washington, DC. House Committee on Education and the Workforce.

    This document presents the transcript (and written statements) of a congressional hearing on the potential politicization of the National Assessment of Educational Progress (NAEP) and the trustworthiness of the scores that the states received during the 1998 reading assessment. It addresses whether Vice President Al Gore's "release" of…

  11. Meloplication of the malar fat pads by percutaneous cable-suture technique for midface rejuvenation: outcome study (392 cases, 6 years' experience).

    PubMed

    Sasaki, Gordon H; Cohen, Andrew T

    2002-08-01

    The aging anterior midface is restored by reversing the contour undulations produced by sagging of the malar fat pad complex toward the nasolabial line. The convex irregularities include the exposed bulges of the post-septal fat, the unveiled malar bag, and the prominent nasolabial fold. The depressed irregularities are represented by the cresent-shaped hollow at the lid-cheek junction, the accentuated nasojugal groove, and the deepening nasolabial line. Repositioning of the ptotic malar fat pad, among other elements of meloplasty, represents a key procedure. In this study, the malar fat pad has been defined as a fan-shaped structure by external anatomic landmarks that correlate closely to the findings in cadaveric dissections and clinical cases, confirmed by the findings of spiral computed tomographic scanning. A simple but powerful adjustable and long-lasting percutaneous suture elevation technique was developed over the past 6 years by the senior author (G.H.S.) to reposition the fat pad in a superolateral direction. Through a dot incision within the nasolabial line, a permanent CV-3 Gore-Tex (or 4-0 clear Prolene) suspension suture, looped through a Gore-Tex anchor graft, suspends the malar fat pad in a direction perpendicular to the nasolabial line. A second suspension system is identically passed through another lower dot incision to broaden the repositioning vectors on the malar fat pad. Tension on each of the paired suture ends elevates the malar fat pad by 1 to 3 mm as measured from the nasolabial dot incisions. The sutures are fixed to the deep temporal fascia through a Gore-Tex tab, effectively stabilizing the soft-tissue repositioning. This maneuver may be performed in younger patients who present with an isolated malar fat pad ptosis without excess facial skin. The procedure may also be incorporated into open rhytidectomies to address this recalcitrant area along with superficial musculoaponeurotic system tightening. A total of 392 patients since 1995

  12. Personalizing Post Titles in the Online Classroom: A Best Practice?

    ERIC Educational Resources Information Center

    Evans, Shelley; Steele, John; Robertson, Sarah; Dyer, Thomas

    2017-01-01

    The need for student engagement is ever present in the online classroom as engaged students are more likely to feel connected with course material, classmates, instructors, and their university (Drouin & Vartanian, 2010; Wilson & Gore, 2013). According to Tayebinik and Puteh (2013), engaged students often achieve higher final scores in the…

  13. Artificial Ligaments: Promise or Panacea?

    ERIC Educational Resources Information Center

    Lubell, Adele

    1987-01-01

    The Food and Drug Administration has approved a prosthetic ligament for limited use in persons with damaged anterior cruciate ligaments (ACL). This article addresses ligament repair, ACL tears, current treatment, development of the Gore-Tex artificial ligament, other artificial ligaments in process, and arguments for and against their use.…

  14. Alzheimer's Disease and Related Dementias. Hearing before the Subcommittee on Aging of the Committee on Labor and Human Resources. United States Senate, Ninety-Ninth Congress, Second Session on Review of Health Care Services Available for People with Alzheimer's Disease and Related Dementia and To Review Proposals Related to the Treatment of Alzheimer's Disease.

    ERIC Educational Resources Information Center

    Congress of the U.S., Washington, DC. Senate Committee on Labor and Human Resources.

    A Senate hearing reviewing health care services available for people with Alzheimer's disease and related dementia and reviewing proposals related to the treatment of Alzheimer's disease is presented in this document. Statements are given by Senators Charles E. Grassley, Albert Gore, Paula Hawkins, Howard M. Metzenbaum, Larry Pressler, and Paul…

  15. Technology Policy: Information Infrastructure [Information Superhighways and High Performance Computing]. Hearings before the Subcommittee on Technology, Environment and Aviation of the Committee on Science, Space, and Technology. House of Representatives, One Hundred Third Congress, First Session (March 23 and 25, 1993).

    ERIC Educational Resources Information Center

    Congress of the U.S., Washington, DC. House Committee on Science, Space and Technology.

    This document contains transcriptions of testimony and prepared statements on national technology policy with a focus on President Clinton and Vice President Gore's initiatives to support the development of a national information infrastructure. On the first day of the hearing testimony was received from Edward H. Salmon, Chairman, New Jersey…

  16. The Day Child Care Was the Talk of the White House.

    ERIC Educational Resources Information Center

    Neugebauer, Bonnie

    1998-01-01

    Reports on the White House Conference on Child Care held in October, 1997. Includes excerpts from remarks by President Clinton, Vice President Al Gore, Hillary Clinton, legislators, federal and state government officials, and representatives from the Families and Work Institute, National Institute on Out-of-School Time, the Kellogg Foundation, and…

  17. Competitiveness and Campaign '88.

    ERIC Educational Resources Information Center

    Kernan-Schloss, Adam, Ed.; And Others

    This report profiles the positions of the six Democratic and six Republican 1988 presidential candidates on policy issues affecting U.S. competitiveness in the global economy. Candidate profiles are provided for: Bruce Babbitt, Michael Dukakis, Richard Gephardt, Albert Gore, Jr., Jesse Jackson, and Paul Simon (Democrats); and George Bush, Robert…

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ruebben, Alexander; Tettoni, Serena; Muratore, Pierluigi

    To evaluate the feasibility of percutaneous treatment of iliac aneurysms, a covered stent was inserted in nine men suffering from common iliac artery aneurysms (six cases), external iliac aneurysms (one case), or pseudoaneurysms (two cases). Placement of the stent was successful in all patients. In one patient, an endoprosthesis thrombosed after 15 days, but was successfully treated by thrombolysis and additional stent placement. At the follow-up examinations (mean period 22 months) all stent-grafts had remained patent. No late leakage or stenosis was observed.

  19. A Lost Opportunity? Vocational Education in Physical Education

    ERIC Educational Resources Information Center

    Brown, Seth Earl; Macdonald, Doune

    2011-01-01

    Background: Vocational education in Australia and elsewhere has a history of being gendered and classed, thereby limiting the post-school options of students undertaking this form of study. Drawing on Foucauldian theory, the authors used Gore's eight techniques of power to examine the micro-functioning of power relations at two case sites.…

  20. Insurance: Profitability of the Medical Malpractice and General Liability Lines. Report to Congressional Requesters.

    ERIC Educational Resources Information Center

    General Accounting Office, Washington, DC.

    This report on the profitability of the property/casualty insurance industry and in particular of the medical malpractice insurance line was prepared at the request of Representatives Henry A. Waxman and James J. Florio and Senators Paul Simon, Daniel K. Inouye, Albert Gore, Jr., and Jay D. Rockefeller. Four different estimates of medical…

  1. Proceedings of the 1990 Annual Meeting of the Association for Education in Journalism and Mass Communication (73rd, Minneapolis, Minnesota, August 1-4, 1990). Part I: Media and Law.

    ERIC Educational Resources Information Center

    Association for Education in Journalism and Mass Communication.

    This section of the proceedings is comprised of 11 papers dealing with the relationship between media and the law. Papers include: "Equal before the Law: Three Media Myths of the American Legal System" (Henry Itkin); "The Role of Senator Albert Gore, Jr. in Satellite/Cable Legislation" (Michael B. Doyle); "The Law of…

  2. Globalization and Teacher Education

    ERIC Educational Resources Information Center

    Flinders, David J.

    2009-01-01

    Educational researchers and teacher educators are often concerned with immediate and practical questions. How can health teachers help youth avoid substance abuse? Should a high school biology teacher show Al Gore's "An Inconvenient Truth," or is that film too political for a science classroom? What sports should be included in a physical…

  3. FLIGHTFAX: Army Aviation Risk-Management Information. Volume 27, Number 11, November 1999. Flying Habits and Judgment are Infectious

    DTIC Science & Technology

    1999-11-01

    hatcanl they do to mie ? ,’Inth igt against accidents, on h ngins true- *•.,••, German hotdogs :get aitae dh angodjudgmn on th pato taste of Goring...subject to change. "... leaders must be willinq to underwrite their subordinates’ honest errors and coach them on to excellence, without toleratinq

  4. Regression Analyses on the Butterfly Ballot Effect: A Statistical Perspective of the US 2000 Election

    ERIC Educational Resources Information Center

    Wu, Dane W.

    2002-01-01

    The year 2000 US presidential election between Al Gore and George Bush has been the most intriguing and controversial one in American history. The state of Florida was the trigger for the controversy, mainly, due to the use of the misleading "butterfly ballot". Using prediction (or confidence) intervals for least squares regression lines…

  5. Who Should Be the Winner: A "Post Hoc" Analysis of the 2000 US Election

    ERIC Educational Resources Information Center

    Wu, D. W.

    2006-01-01

    The 2000 US presidential election between Al Gore and George W. Bush has been the most intriguing and controversial in American history. Using the Florida ballot data, Wu showed that the 2000 election result could have been reversed had the "butterfly ballot effect" been eliminated. Through a combinatorial approach, Harger concluded that…

  6. Education Moves into High Gear on the Information Highway.

    ERIC Educational Resources Information Center

    Noor Al-Deen, Hana S.

    The utilization of teleconferencing as part of the information highway, mainly among schools in North Carolina, is examined. The National Information Infrastructure, outlined by Vice President Gore in January 1994, is the official name of the information system. The U.S. Congress issued four pieces of legislation in support of high-tech…

  7. 77 FR 12087 - Atomic Safety and Licensing Board Panel; Strata Energy, Inc.; Memorandum and Order (Notice of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-28

    ... part 40.\\*\\ If issued, that license would authorize SEI to construct and operate an in situ recovery (ISR) uranium project at the Ross site in Crook County, Wyoming. In response to an October 27, 2011... Commission in its decision in Sequoyah Fuels Corp. (Gore, Oklahoma Site), CLI-03-15, 58 NRC 349 (2003...

  8. An Integrated Assessment of Climate Change on Timber Markets of the Southern United States

    Treesearch

    Joseph E. de Steiguer; Steven G. McNulty

    1998-01-01

    There is growing public concern that continued emissions of greenhouse gases could cause the global climate to change (Gore, 1992). Altered global climate could, in turn, have impacts on the earth's natural systems and, ultimately, on human welfare (Office of Technology Assessment, 1991). Economic assessments of these potential welfare impacts are useful to...

  9. Voter Learning and Interest in the 2000 Presidential Election: Did the Media Matter?

    ERIC Educational Resources Information Center

    Weaver, David; Drew, Dan

    2001-01-01

    Examines the relationships of exposure and attention to various news media, including the Internet, with information learned about the issue positions of George Bush and Al Gore, Jr., and intention to vote among a random sample of adult residents of Indiana. Compares results to earlier studies. Confirms the importance of television news and…

  10. Making Afterschool Count: Communities & Schools Working Together, 1998.

    ERIC Educational Resources Information Center

    Beachum-Bilby, Sheila; Seymour, Liz; Krajewski, Fran

    1998-01-01

    This document consists of the first two issues of a brief (usually 6-page) serial publication highlighting the Making After-School Count initiative, programs across the country wherein communities and schools cooperate to serve children after school hours. The June 1998 issue discusses a teleconference discussion with Vice President Al Gore to…

  11. Presidential Promises.

    ERIC Educational Resources Information Center

    Kennedy, Mike

    2000-01-01

    Explores the different strategies between George W. Bush and Al Gore for improving education. The pros and cons of school vouchers are highlighted along with issues of school safety, tax credits, teacher hiring increases, charter schools, and universal access to education. Republican and Democratic proposals on school safety conclude the article.…

  12. Early cannulation prosthetic graft (Acuseal) for arteriovenous access: a useful option to provide a personal vascular access solution.

    PubMed

    Aitken, Emma L; Jackson, Andrew J; Kingsmore, David B

    2014-01-01

    Early cannulation arteriovenous grafts (ecAVGs), such as the GORE Acuseal, have "low bleed" properties permitting cannulation within 24 hours of insertion. They may provide an alternative to tunneled central venous catheters (and associated line complications) in patients requiring urgent vascular access. We present our early experience of 37 patients treated with the GORE Acuseal ecAVG. A total of 11 upper limb, 24 lower limb and 2 complex graft procedures were performed. Indications for ecAVG were as follows: bridge to transplantation (21.6%); bridge to arteriovenous fistula (AVF) maturation (8.1%); AVF salvage (8.1%); no native options (67.6%, including 17 patients with bilateral central vein stenosis); 36 AVGs (97.3%) were successfully cannulated. Mean time to first cannulation: 30.4±23.4 hours (range: 2-192). Primary and secondary patency rates at 3, 6 and 12 months were 64.9%, 48.6%, 32.4% and 70.2%, 59.4%, 40.5% respectively. The systemic bacteremia rate was 0.2 per 1,000 access days. There was one perioperative death. Other complications included hematoma at cannulation sites (n=9), pseudoaneurysm (n=3) and local infection at graft site (n=6). A total of 26 of 37 patients (70.6%) achieved a "personal vascular access solution": bridge to transplantation (n=8), bridge to functioning AVF/interposition AVG (n=5), maintenance hemodialysis via ecAVG (n=13); death with functioning AVG (n=1). Early experience with the GORE Acuseal is encouraging. Patency and bacteremia rates are at least comparable to standard polytetrafluoroethylene grafts. ecAVGs have permitted cannulation within 24 hours of insertion and line avoidance in the majority of patients. Nearly three-quarters of patients achieved a definitive "personal vascular access solution" from their ecAVG.

  13. GAS/LIQUID MEMBRANES FOR NATURAL GAS UPGRADING

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Howard S. Meyer

    A new project was initiated this quarter to develop gas/liquid membranes for natural gas upgrading. Efforts have concentrated on legal agreements, including alternative field sites. Gas Technology Institute (GTI) is conducting this research program whose objective is to develop gas/liquid membranes for natural gas upgrading to assist DOE in achieving their goal of developing novel methods of upgrading low quality natural gas to meet pipeline specifications. Kvaerner Process Systems (KPS) and W. L. Gore & Associates (GORE) gas/liquid membrane contactors are based on expanded polytetrafluoroethylene (ePTFE) membranes acting as the contacting barrier between the contaminated gas stream and the absorbingmore » liquid. These resilient membranes provide much greater surface area for transfer than other tower internals, with packing densities five to ten times greater, resulting in equipment 50-70% smaller and lower weight for the same treating service. The scope of the research program is to (1) build and install a laboratory- and a field-scale gas/liquid membrane absorber; (2) operate the units with a low quality natural gas feed stream for sufficient time to verify the simulation model of the contactors and to project membrane life in this severe service; and (3) conducted an economic evaluation, based on the data, to quantify the impact of the technology. Chevron, one of the major producers of natural gas, has offered to host the test at a gas treating plant. KPS will use their position as a recognized leader in the construction of commercial amine plants for building the unit along with GORE providing the membranes. GTI will provide operator and data collection support during lab- and field-testing to assure proper analytical procedures are used. Kvaerner and GTI will perform the final economic evaluation. GTI will provide project management and be responsible for reporting and interactions with DOE on this project.« less

  14. GAS/LIQUID MEMBRANES FOR NATURAL GAS UPGRADING

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Howard S. Meyer

    Efforts this quarter have concentrated on legal agreements, including alternative field sites. Preliminary design of the bench-scale equipment has been initiated. Gas Technology Institute (GTI) is conducting this research program whose objective is to develop gas/liquid membranes for natural gas upgrading to assist DOE in achieving their goal of developing novel methods of upgrading low quality natural gas to meet pipeline specifications. Kvaerner Process Systems (KPS) and W. L. Gore & Associates (GORE) gas/liquid membrane contactors are based on expanded polytetrafluoroethylene (ePTFE) membranes acting as the contacting barrier between the contaminated gas stream and the absorbing liquid. These resilient membranesmore » provide much greater surface area for transfer than other tower internals, with packing densities five to ten times greater, resulting in equipment 50--70% smaller and lower weight for the same treating service. The scope of the research program is to (1) build and install a laboratory- and a field-scale gas/liquid membrane absorber; (2) operate the units with a low quality natural gas feed stream for sufficient time to verify the simulation model of the contactors and to project membrane life in this severe service; and (3) conducted an economic evaluation, based on the data, to quantify the impact of the technology. Chevron, one of the major producers of natural gas, has offered to host the test at a gas treating plant. KPS will use their position as a recognized leader in the construction of commercial amine plants for building the unit along with GORE providing the membranes. GTI will provide operator and data collection support during lab- and field-testing to assure proper analytical procedures are used. Kvaerner and GTI will perform the final economic evaluation. GTI will provide project management and be responsible for reporting and interactions with DOE on this project.« less

  15. GAS/LIQUID MEMBRANES FOR NATURAL GAS UPGRADING

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Howard S. Meyer

    Gas Technology Institute (GTI) is conducting this research program whose objective is to develop gas/liquid membranes for natural gas upgrading to assist DOE in achieving their goal of developing novel methods of upgrading low quality natural gas to meet pipeline specifications. Kvaerner Process Systems (KPS) and W. L. Gore & Associates (GORE) gas/liquid membrane contactors are based on expanded polytetrafluoroethylene (ePTFE) membranes acting as the contacting barrier between the contaminated gas stream and the absorbing liquid. These resilient membranes provide much greater surface area for transfer than other tower internals, with packing densities five to ten times greater, resulting inmore » equipment 50-70% smaller and lower weight for the same treating service. The scope of the research program is to (1) build and install a laboratory- and a field-scale gas/liquid membrane absorber; (2) operate the units with a low quality natural gas feed stream for sufficient time to verify the simulation model of the contactors and to project membrane life in this severe service; and (3) conducted an economic evaluation, based on the data, to quantify the impact of the technology. Chevron, one of the major producers of natural gas, has offered to host the test at a gas treating plant. KPS will use their position as a recognized leader in the construction of commercial amine plants for building the unit along with GORE providing the membranes. GTI will provide operator and data collection support during lab- and field-testing to assure proper analytical procedures are used. KPS and GTI will perform the final economic evaluation. GTI will provide project management and be responsible for reporting and interactions with DOE on this project. Efforts this quarter have concentrated on legal agreements, including alternative field sites. Preliminary design of the bench-scale equipment continues.« less

  16. GAS/LIQUID MEMBRANES FOR NATURAL GAS UPGRADING

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Howard S. Meyer

    Gas Technology Institute (GTI) is conducting this research program whose objective is to develop gas/liquid membranes for natural gas upgrading to assist DOE in achieving their goal of developing novel methods of upgrading low quality natural gas to meet pipeline specifications. Kvaerner Process Systems (KPS) and W. L. Gore & Associates (GORE) gas/liquid membrane contactors are based on expanded polytetrafluoroethylene (ePTFE) membranes acting as the contacting barrier between the contaminated gas stream and the absorbing liquid. These resilient membranes provide much greater surface area for transfer than other tower internals, with packing densities five to ten times greater, resulting inmore » equipment 50-70% smaller and lower weight for the same treating service. The scope of the research program is to (1) build and install a laboratory- and a field-scale gas/liquid membrane absorber; (2) operate the units with a low quality natural gas feed stream for sufficient time to verify the simulation model of the contactors and to project membrane life in this severe service; and (3) conducted an economic evaluation, based on the data, to quantify the impact of the technology. Chevron, one of the major producers of natural gas, has offered to host the test at a gas treating plant. KPS will use their position as a recognized leader in the construction of commercial amine plants for building the unit along with GORE providing the membranes. GTI will provide operator and data collection support during lab- and field-testing to assure proper analytical procedures are used. Kvaerner and GTI will perform the final economic evaluation. GTI will provide project management and be responsible for reporting and interactions with DOE on this project. Efforts this quarter have concentrated on legal agreements, including alternative field sites. Preliminary design of the bench-scale equipment continues.« less

  17. GAS/LIQUID MEMBRANES FOR NATURAL GAS UPGRADING

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Howard S. Meyer

    Efforts this quarter have concentrated on legal agreements, including alternative field sites. Preliminary design of the bench-scale equipment continues. Gas Technology Institute (GTI) is conducting this research program whose objective is to develop gas/liquid membranes for natural gas upgrading to assist DOE in achieving their goal of developing novel methods of upgrading low quality natural gas to meet pipeline specifications. Kvaerner Process Systems (KPS) and W. L. Gore & Associates (GORE) gas/liquid membrane contactors are based on expanded polytetrafluoroethylene (ePTFE) membranes acting as the contacting barrier between the contaminated gas stream and the absorbing liquid. These resilient membranes provide muchmore » greater surface area for transfer than other tower internals, with packing densities five to ten times greater, resulting in equipment 50--70% smaller and lower weight for the same treating service. The scope of the research program is to (1) build and install a laboratory- and a field-scale gas/liquid membrane absorber; (2) operate the units with a low quality natural gas feed stream for sufficient time to verify the simulation model of the contactors and to project membrane life in this severe service; and (3) conducted an economic evaluation, based on the data, to quantify the impact of the technology. Chevron, one of the major producers of natural gas, has offered to host the test at a gas treating plant. KPS will use their position as a recognized leader in the construction of commercial amine plants for building the unit along with GORE providing the membranes. GTI will provide operator and data collection support during lab- and field-testing to assure proper analytical procedures are used. Kvaerner and GTI will perform the final economic evaluation. GTI will provide project management and be responsible for reporting and interactions with DOE on this project.« less

  18. Improvement of thermophysiological stress in participants wearing protective clothing for spraying pesticide, and its application in the field.

    PubMed

    Hayashi, C; Tokura, H

    2000-04-01

    Thermoregulatory responses were compared under two experimental conditions, in the laboratory (Experiment I), and in the field (Experiment II), between two kinds of protective clothing for spraying pesticides. One was currently being used (Type A), and was composed of ready made Gore-Tex clothing, mask, polyurethane gloves and rubber boots. The other one was newly designed (Type B), and was composed of pesticide-proof clothing (100% cotton with water repellent finish), mask, Gore-Tex gloves, and special boots consisting of rubber for the feet and ankle and Gore-Tex around the legs. In addition, the head and chest were cooled by frozen gel strips fixed in the cap and undershirt. In Experiment I, five female adults took part, in a climate-chamber controlled at an ambient temperature of 28 degrees C and a relative humidity of 60%. In Experiment II, five farmers (one male and four female) were tested in an apple orchard in July, August and September. The main results are summarized as follows: (1) change of rectal temperature was inhibited more effectively in Type B in Experiment I, (2) change of heart rate tended to be lower in Type B than in Type A in both experiments, (3) salivary lactic acid concentration at the end of the first exercise was significantly higher in Type A than in Type B in Experiment I, (4) the number of contractions in the handgrip exercise which was performed immediately after the third exercise, was significantly smaller in Type A than in Type B in Experiment I, (5) subjective comfort sensation was significantly improved in Type B in Experiments I and II. Thus, it was concluded that the newly designed protective clothing could reduce thermal stress during the spraying of pesticides in an apple orchard in summer.

  19. Nickel elution properties of contemporary interatrial shunt closure devices.

    PubMed

    Verma, Divya Ratan; Khan, Muhammad F; Tandar, Anwar; Rajasekaran, Namakkal S; Neuharth, Renée; Patel, Amit N; Muhlestein, Joseph B; Badger, Rodney S

    2015-02-01

    We sought to compare nickel elution properties of contemporary interatrial shunt closure devices in vitro. There are two United States Food and Drug Administration (FDA)-approved devices for percutaneous closure of secundum atrial septal defect: the Amplatzer septal occluder (ASO; St Jude Medical Corporation) and Gore Helex septal occluder (HSO; W.L. Gore & Associates). The new Gore septal occluder (GSO) device is in clinical trials. These are also used off-label for patent foramen ovale closure in highly selected patients. These devices have high nickel content. Nickel allergy is the most common reason for surgical device explantation. Nickel elution properties of contemporary devices remain unknown. We compared nickel elution properties of 4 devices - ASO, GSO, HSO, and sternal wire (SW) - while Dulbecco's phosphate-buffered saline (DPBS) served as control. Three samples of each device were submerged in DPBS. Nickel content was measured at 14 intervals over 90 days. Nickel elution at 24 hours, compared to control (0.005 ± 0.0 mg/L), was significantly higher for ASO (2.98 ± 1.65 mg/L; P=.04) and SW (0.03 ± 0.014 mg/L; P=.03). Nickel levels at 90 days, compared to control (0.005 ± 0.0 mg/L) and adjusting for multiple comparisons, were significantly higher for ASO (19.80 ± 2.30 mg/L; P=.01) and similar for HSO (P=.34), GSO (P=.34), and SW (P=.34). ASO had significantly higher nickel elution compared to HSO, GSO, and SW (P=.01). There is substantial variability in nickel elution; devices with less exposed nickel (HSO and GSO) have minimal elution. The safety of low nickel elution devices in patients with nickel allergy needs to be evaluated in prospective trials.

  20. Proteins--The Basis of Life

    ERIC Educational Resources Information Center

    Wrigley, Colin

    2012-01-01

    Proteins are a diverse class of biochemical macromolecules, including substances as (apparently) unrelated as silk and sinew, hair and horn, feathers and flagella, enzymes and epidermis, gelatine (jelly) and gluten and gore, spider web, meat and fish muscle. Yet they are unified by being polymers of amino acids. Discovery of the nature of proteins…

  1. Shortage of Engineers and Scientists. Hearing before the Subcommittee on Science, Technology, and Space of the Committee on Commerce, Science, and Transportation. United States Senate One Hundred First Congress, Second Session on Training Scientists and Engineers for the Year 2000--The National Science Foundation's Role.

    ERIC Educational Resources Information Center

    Congress of the U.S., Washington, DC. Senate Committee on Commerce, Science, and Transportation.

    This document is the transcript of a Congressional hearing focusing on the status of the training of scientists and engineers in the United States and the role of the federal government in the improvement of this situation. Included are opening statements from Senators Albert Gore, Jr. (Tennessee), Robert W. Kasten, Jr. (Wisconsin), and Larry…

  2. Deeper Insight into Fluorescence-Excitation of Molecules by Light

    ERIC Educational Resources Information Center

    Wahab, M. Farooq; Gore, Gordon R.

    2013-01-01

    In a recent issue of "TPT," Gordon Gore made interesting observations about the red or yellow fluorescence when laser beams are passed through olive oil. With the excellent visuals contained in that article, we present a pictorial explanation of the questions that were raised in Ref 1 ("Fun with Fluorescence in Olive Oil,"…

  3. Greening Spires: Universities and the Green Agenda

    ERIC Educational Resources Information Center

    Universities UK, 2008

    2008-01-01

    We are in a time of unprecedented interest in the environment, especially climate change. What used to be purely an environmental issue has been pushed to the forefront of public and media interest by the release of the "Stern Review on the Economics of Climate Change" and Al Gore's documentary "An Inconvenient Truth."…

  4. CNN Newsroom Classroom Guides, March 2000.

    ERIC Educational Resources Information Center

    Turner Educational Services, Inc., Newtown, PA.

    These classroom guides, designed to accompany the daily CNN (Cable News Network) Newsroom broadcasts for the month of March, provide program rundowns, suggestions for class activities and discussion, Web links, and a list of related news terms. Top stories include: primary victories in the Bush campaign and preparations by Gore and Bradley for the…

  5. An Inconvenient Truth: An Application of the Extended Parallel Process Model

    ERIC Educational Resources Information Center

    Goodall, Catherine E.; Roberto, Anthony J.

    2008-01-01

    "An Inconvenient Truth" is an Academy Award-winning documentary about global warming presented by Al Gore. This documentary is appropriate for a lesson on fear appeals and the extended parallel process model (EPPM). The EPPM is concerned with the effects of perceived threat and efficacy on behavior change. Perceived threat is composed of an…

  6. P=fm: Fostering Innovative Teaching and Learning in a Digital Age

    ERIC Educational Resources Information Center

    Fluellen, Jerry E., Jr.

    2012-01-01

    A larger scale context for power teaching includes ideas from Duane Elgin, Lester Brown, Al Gore and many others. Collectively, they say the convergence of systems level global problems without national borders place before humankind a choice the species has never encountered in 195,000 years of life on "Spaceship Earth." In Elgin's…

  7. Economic Prospects for African Americans, 2001-2010: Politics and Promises.

    ERIC Educational Resources Information Center

    Brimmer, Andrew F.

    Given the different economic policy approaches of the two candidates for the 2000 presidential election, Vice President Al Gore and Texas Governor George W. Bush, the Joint Center for Political and Economic Studies analyzed and assessed the plans put forth by both candidates, focusing on the expected impacts on African Americans. Six analyses were…

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lanciego, Carlos; Rodriguez, Mario; Rodriguez, Adela

    The use of metallic stents in the management of benign and malignant superior vena cava syndrome (SVCS) is well documented. Symptomatic stenosis or occlusion of the SVC is a rare complication of a transvenous permanent pacemaker implant. Suggested treatments have included anticoagulation therapy, thrombolysis, balloon angioplasty and surgery. More recently, endovascular stenting has evolved as an attractive alternative but the data available in the literature are limited. We describe a case in which venous stenting with a Wallstent endoprosthesis was used successfully. The patient remains symptom free and with normal pacemaker function 36 months later.

  9. Major surgery in an osteosarcoma patient refusing blood transfusion: case report.

    PubMed

    Dhanoa, Amreeta; Singh, Vivek A; Shanmugam, Rukmanikanthan; Rajendram, Raja

    2010-11-08

    We describe an unusual case of osteosarcoma in a Jehovah's Witness patient who underwent chemotherapy and major surgery without the need for blood transfusion. This 16-year-old girl presented with osteosarcoma of the right proximal tibia requiring proximal tibia resection, followed by endoprosthesis replacement. She was successfully treated with neoadjuvant chemotherapy and surgery with the support of haematinics, granulocyte colony-stimulating factor, recombinant erythropoietin and intraoperative normovolaemic haemodilution. This case illustrates the importance of maintaining effective, open communication and exploring acceptable therapeutic alternative in the management of these patients, whilst still respecting their beliefs.

  10. Knee arthrodesis after infected tumor mega prosthesis of the knee using an intramedullary nail for callus distraction.

    PubMed

    Kühne, C A; Taeger, G; Nast-Kolb, D; Ruchholtz, S

    2003-03-01

    Infected tumor endoprosthesis of the knee in young patients can prove to be challenging. Common procedures are débridement and prosthesis reimplantation, amputation, revision arthroplasty, and arthrodesis. We report the case of a 44-year-old man treated by arthrodesis followed by callus distraction after removal of an infected tumor mega prosthesis (Kotz type). Callus distraction was performed over a distance of 11 cm in 4 months using a femorotibial intramedullary nail with an external traction rope-winch system. The clinical, radiological, technical, and therapeutic features are discussed.

  11. Combined medial displacement calcaneal osteotomy, subtalar joint arthrodesis, and ankle arthrodiastasis for end-stage posterior tibial tendon dysfunction.

    PubMed

    Stapleton, John J; Belczyk, Ronald; Zgonis, Thomas; Polyzois, Vasilios D

    2009-04-01

    Combining an ankle arthrodiastasis with a medial displacement calcaneal osteotomy and a subtalar joint arthrodesis offers surgeons a joint-sparing procedure for young and active patients who have end-stage posterior tibial tendon dysfunction and ankle joint involvement. An isolated subtalar joint arthrodesis or triple arthrodesis combined with an ankle arthrodiastasis is an option that can be used in certain case scenarios. Delaying the need for a joint destructive procedure through an ankle arthrodiastasis, however, may have a great impact in the near future, as advancements are underway to improve the use of ankle endoprosthesis.

  12. [Endoprosthesis failure in the ankle joint : Histopathological diagnostics and classification].

    PubMed

    Müller, S; Walther, M; Röser, A; Krenn, V

    2017-03-01

    Endoprostheses of the ankle joint show higher revision rates of 3.29 revisions per 100 component years. The aims of this study were the application and modification of the consensus classification of the synovia-like interface membrane (SLIM) for periprosthetic failure of the ankle joint, the etiological clarification of periprosthetic pseudocysts and a detailed measurement of proliferative activity (Ki67) in the region of osteolysis. Tissue samples from 159 patients were examined according to the criteria of the standardized consensus classification. Of these, 117 cases were derived from periprosthetic membranes of the ankle. The control group included 42 tissue specimens from the hip and knee joints. Particle identification and characterization were carried out using the particle algorithm. An immunohistochemical examination with Ki67 proliferation was performed in all cases of ankle pseudocysts and 19 control cases. The consensus classification of SLIM is transferrable to endoprosthetic failure of the ankle joint. Periprosthetic pseudocysts with the histopathological characteristics of the appropriate SLIM subtype were detectable in 39 cases of ankle joint endoprostheses (33.3%). The mean value of the Ki67 index was 14% and showed an increased proliferation rate in periprosthetic pseudocysts of the ankle (p-value 0.02037). In periprosthetic pseudocysts an above average higher detection rate of type 1 SLIM induced by abrasion (51.3%) with an increased Ki67 proliferation fraction (p-value 0.02037) was found, which can be interpreted as local destructive intraosseus synovialitis. This can be the reason for formation of pseudocystic osteolysis caused by high mechanical stress in ankle endoprostheses. A simplified diagnostic classification scoring system of dysfunctional endoprostheses of the ankle is proposed for collation of periprosthetic pseudocysts, ossifications and the Ki67 proliferation fraction.

  13. [Endoprosthesis of the ankle joint. Indications and long-term results].

    PubMed

    Endrich, B; Terbrüggen, D

    1991-10-01

    The treatment of a post-traumatic, progressively more painful ankle joint causes increasing disablement. It might require alternatives to conventional surgery if a patient does not consent to ankle arthrodesis to alleviate the pain. Therefore, we report on a retrospective study of 10 patients (age 25-73 years at the time of surgery). All of them refused arthrodesis; thus 10 total ankle arthroplasties were performed between 1982 and 1989. 5 women and 5 men were treated who have been suffering from severe post-traumatic arthrosis for 3-46 years. Since performance of a single-axis arthroplasty (ICLH prosthesis) in each patient, the mean follow-up has been 4.6 years. One year after surgery, the results could be considered good or excellent in 9 of the 10 patients; only 1 person experienced local wound infection, which led to removal of the implant 4 months later and ultimately to arthrodesis. Two years later, 7 patients are eligible for follow-up because 1 underwent surgery in February 1989. Another patient experienced aseptic loosening after 18 months; he was admitted to our hospital for arthrodesis. Three years after endoprosthetic surgery, all except 1 woman with occasional pain and stiffness were found to have satisfactory results on follow-up. The relief of pain was gratifying in all patients, with ankle function well maintained (at least 0-0-30 degrees). At present, the prosthesis is still functional in 6 patients (surgery 1.5-8 years ago). They can go about their usual daily business without apparent pain and with appropriate function; 2 of them, however, show radiolucent lines on standard X-rays of the ankle, suggesting some loosening.(ABSTRACT TRUNCATED AT 250 WORDS)

  14. Integrating Barriers to Caucasian Lesbians' Career Development and Super's Life-Span, Life-Space Approach

    ERIC Educational Resources Information Center

    House, Chloe J. C.

    2004-01-01

    Researchers and practitioners do not fully understand the nature and extent of actual and perceived barriers in lesbians' career development (S. L. Morrow, P. A. Gore, & B. W. Campbell, 1996). In this study, 10 lesbian women, ages 42 to 64 years, were interviewed and asked to identify barriers to career development due to sexual identity.…

  15. The Education Election: Guess Who's Coming to School.

    ERIC Educational Resources Information Center

    Weisman, Jonathan

    2000-01-01

    Describes Vice President Al Gore's 2000 presidential campaign efforts at one Michigan high school, from the arrival of advance Secret Service agents to scope out the school, to determination of what the Vice President would do during his 7-hour visit, to who would host the Vice President, to how students and staff responded to the visit. (SM)

  16. The 2012 Brown Center Report on American Education: How Well Are American Students Learning? With Sections on Predicting the Effect of the Common Core State Standards, Achievement Gaps on the Two NAEP Tests, and Misinterpreting International Test Scores. Volume III, Number 1

    ERIC Educational Resources Information Center

    Loveless, Tom

    2012-01-01

    This edition of the Brown Center Report on American Education marks the first issue of volume three--and eleventh issue over all. The first installment was published in 2000, just as the Presidential campaigns of George W. Bush and Al Gore were winding down. Education was an important issue in that campaign. It has not been thus far in the current…

  17. Taxing pollution instead of labor: Is it a prudent CO[sub 2] reduction policy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sanghi, A.K.; Joseph, A.L.

    Any serious attempt to reduce carbon dioxide emissions will require reductions from all sectors of the economy. The authors believe that top-down approaches to a carbon tax will generate heavy excess revenues, thus causing administrative and equity problems. They suggest that a better approach, which was espoused by Vice President Gore, could come through a targeted trust fund approach.

  18. Benefit from NASA

    NASA Image and Video Library

    2004-04-15

    During the Apollo era Marshall Space Flight Center's engineers developed the Magnetomotive Hammer to remove distortions from Saturn V bulkhead gore segments. Using an intense magnetic field, the Hammer removed manufacturing distortions from rejected segments which otherwise would have been discarded at a cost of $30,000 each. Various automobile, ship and aircraft manufacturers adoped the technology for commercial use.

  19. Surgical Access to Jejunal Veins for Local Thrombolysis and Stent Placement in Portal Vein Thrombosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schellhammer, Frank, E-mail: frank.schellhammer@med.uni-duesseldorf.d; Esch, Jan Schulte am; Hammerschlag, Sascha

    2008-07-15

    Portal vein thrombosis is an infrequent entity, which may cause high morbidity and mortality. We report a case of portal vein thrombosis due to benign stenosis following partial pancreatoduodenectomy with segmental replacement of the portal vein by a Gore-tex graft. Using a surgical access to jenunal veins, local thrombolysis, mechanical fragmentation of thrombus, and stent placement were successfully performed.

  20. iPSCs: induced back to controversy.

    PubMed

    Panopoulos, Athanasia D; Ruiz, Sergio; Izpisua Belmonte, Juan Carlos

    2011-04-08

    Several recent reports (Mayshar et al., 2010; Laurent et al., 2011; Lister et al., 2011; Gore et al., 2011; Hussein et al., 2011) uncover genetic and epigenetic alterations in induced pluripotent stem cells, stimulating debate about their future. However, will these important findings really impact what we hope to gain? Copyright © 2011 Elsevier Inc. All rights reserved.

  1. Closest Presidential Race Ever...Or Is It?

    ERIC Educational Resources Information Center

    Constitutional Rights Foundation, Los Angeles, CA.

    All evening on election night 2000, candidates George W. Bush and Al Gore were deadlocked in the tightest-ever race for the office of President of the United States. As the numbers were reported from each state, the battle for votes in the electoral college swung back and forth from Republicans to Democrats. The next morning, the issue was still…

  2. [The best of thrombosis in 2002].

    PubMed

    Maillard, L

    2003-01-01

    In the area of myocardial infarction one is reminded of the publication of the CADILLAC study which has reopened the debate on the systematic use of GpIIbIIIa inhibitors in the acute phase of myocardial infarction complementing primary angioplasty with the placement of an endoprosthesis. New modalities for thrombolysis are in the course of evaluation, notably Eptibaphide Alteplase combination in the INTRO-AMI study and Tenecteplase Abciximab in association with enoxaparine or non-fractionated heparin in the TIMI 23 study. Several studies comparing angioplasty to lysis have been published. STOPAMI 2 evaluated myocardial salvage in the framework of primary angioplasty with placement of an endoprosthesis combined with abciximab infusion in comparison with half dose fibrinolysis associated with abciximab. CAPTIM is a strategy evaluation comparing the results of pre-hospital fibrinolysis with primary angioplasty. With the RITA 3 study the interventional approach definitely comes top in comparison with a conservative approach for the treatment of unstable angina. One is equally reminded of the changes in the ACC/AHA recommendations for the management of unstable angina. The debate continues on the indications for thrombolysis in submassive pulmonary embolus. In the therapeutic area, one is reminded of the update on the interactions between angiotensin converting enzymes and aspirin in treatment and long term coronary syndrome. Finally, at the end of 2001, the work of French teams was published concerning the evaluation of risk of relapse for cerebral vascular accident in the presence of a foramen ovale or an aneurysm of the inter-atrial septum.

  3. Plastic Biliary Stent Occlusion: Factors Involved and Possible Preventive Approaches

    PubMed Central

    Donelli, Gianfranco; Guaglianone, Emilio; Di Rosa, Roberta; Fiocca, Fausto; Basoli, Antonio

    2007-01-01

    Endoscopic biliary stenting is today the most common palliative treatment for patients suffering from obstructive jaundice associated with malignant hepatobiliary tumors or benign strictures. However, recurrent jaundice, with or without cholangitis, is a major complication of a biliary endoprosthesis insertion. Thus, stent removal and replacement with a new one frequently occurs as a consequence of device blockage caused by microbial biofilm growth and biliary sludge accumulation in the lumen. Factors and mechanisms involved in plastic stent clogging arising from epidemiological, clinical and experimental data, as well as the possible strategies to prevent biliary stent failure, will be reviewed and discussed. PMID:17456835

  4. Understanding the Mechanical forces of Self-Expandable Metal Stents in the Biliary Ducts.

    PubMed

    Isayama, Hiroyuki; Nakai, Yousuke; Hamada, Tsuyoshi; Matsubara, Saburo; Kogure, Hirofumi; Koike, Kazuhiko

    2016-12-01

    Self-expandable metallic stent (SEMS) was an effective biliary endoprosthesis. Mechanical properties of SEMS, radial and axial force (RF, AF), may play important roles in the bile duct after placement. RF was well known dilation force and influenced on the occurrence of migration. AF, newly proposed by this author, was defined as the recovery force when the SEMS vended. AF was related with the cause of bile duct kinking, pancreatitis, and cholecystitis due to the compression of the bile duct, orifice of the cystic duct, and pancreatic orifice. Ideal SEMS may show high RF and low AF.

  5. Development of a Flexible Seal for a 60 psi Cryogenic Pressure Box

    NASA Technical Reports Server (NTRS)

    Glass, David E.

    1998-01-01

    A cryogenic pressure box test facility has been designed and fabricated for use at NASA Langley Research Center (LaRC) to subject 5 ft x 6 ft curved panels to cryogenic temperatures and biaxial tensile loads. The cryogenic pressure box is capable of testing curved panels down to -423 F (20 K) with 54 psig maximum pressure. The key challenge in the design and fabrication of the pressure box was the development of a seal that could remain flexible at -423 F and contain 60 psi gaseous helium as the pressurization gas. A C-shaped seal was developed using a Gore-tex woven fabric. Mechanical testing of the fabric at room and elevated temperature, liquid nitrogen temperature, and liquid helium temperature demonstrated the strength and creep resistance of the material over the desired operating range. A small scale cryogenic pressure box was used to test prototype seals at cryogenic temperatures up to 60 psi. Preliminary tests indicated that excessive leakage was present through the seal. As a result, an aluminized mylar liner was placed inside the Gore-tex seal to reduce leakage through the seal. The final seal configuration resulted in minimal pressure loss during seal testing.

  6. Digital Earth reloaded - Beyond the next generation

    NASA Astrophysics Data System (ADS)

    Ehlers, M.; Woodgate, P.; Annoni, A.; Schade, S.

    2014-02-01

    Digital replicas (or 'mirror worlds') of complex entities and systems are now routine in many fields such as aerospace engineering; archaeology; medicine; or even fashion design. The Digital Earth (DE) concept as a digital replica of the entire planet occurs in Al Gore's 1992 book Earth in the Balance and was popularized in his speech at the California Science Center in January 1998. It played a pivotal role in stimulating the development of a first generation of virtual globes, typified by Google Earth that achieved many elements of this vision. Almost 15 years after Al Gore's speech, the concept of DE needs to be re-evaluated in the light of the many scientific and technical developments in the fields of information technology, data infrastructures, citizen?s participation, and earth observation that have taken place since. This paper intends to look beyond the next generation predominantly based on the developments of fields outside the spatial sciences, where concepts, software, and hardware with strong relationships to DE are being developed without referring to this term. It also presents a number of guiding criteria for future DE developments.

  7. Cutting of Gold Foil in the Genesis Laboratory

    NASA Image and Video Library

    2005-02-15

    The facility for storing and examining Genesis solar wind samples consists of two adjacent laboratories. In these laboratories, the cutting of gold foil to be used in the gathering of the solar wind dust aboard the Genesis spacecraft. Views include: The process of cutting gold foil to be used aboard the Genesis spacecraft. The technicians use Gore-Tex suits with filters as to not contaminate the items.

  8. Omega-3 Fatty Acids for Major Depressive Disorder: A Systematic Review

    DTIC Science & Technology

    2015-01-01

    trademark. iii Preface The Defense Centers of Excellence for Psychological Health and Traumatic Brain Injury is interested in determining the efficacy...the Defense Centers of Excellence for Psychological Health and Traumatic Brain Injury and conducted within the Forces and Resources Policy Center of...Excellence for Psychological Health and Traumatic Brain Injury (DCoE). We gratefully acknowledge Kristie Gore for her support and guidance throughout

  9. Advanced concentrator panels

    NASA Technical Reports Server (NTRS)

    Bell, D. M.; Bedard, R. J., Jr.

    1981-01-01

    The prototype fabrication of a lightweight, high-quality cellular glass substrate reflective panel for use in an advanced point-focusing solar concentrator was completed. The reflective panel is a gore shaped segment of an 11-m paraboloidal dish. The overall concentrator design and the design of the reflective panels are described. prototype-specific panel design modifications are discussed and the fabrication approach and procedure outlined.

  10. What It? How Apportionment Methods Choose Our Presidents

    ERIC Educational Resources Information Center

    Caulfield, Michael J.

    2012-01-01

    What if Stephen Douglas instead of Abraham Lincoln had won the U.S. presidential election of 1860? What if John F. Kennedy had not carried some of the eight states he won by 2 percentage points or fewer in 1960? What if six hundred more people in Florida had voted for Al Gore in 2000? And what if, in that same year, the U.S. House of…

  11. Demonstration of the Gore Module for Passive Ground Water Sampling

    DTIC Science & Technology

    2014-06-01

    ix ACRONYMS AND ABBREVIATIONS % RSD percent relative standard deviation 12DCA 1,2-dichloroethane 112TCA 1,1,2-trichloroethane 1122TetCA...Analysis of Variance ROD Record of Decision RSD relative standard deviation SBR Southern Bush River SVOC semi-volatile organic compound...replicate samples had a relative standard deviation ( RSD ) that was 20% or less. For the remaining analytes (PCE, cDCE, and chloroform), at least 70

  12. GAS/LIQUID MEMBRANES FOR NATURAL GAS UPGRADING

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Howard S. Meyer

    Gas Technology Institute (GTI) is conducting this research program whose objective is to develop gas/liquid membranes for natural gas upgrading to assist DOE in achieving their goal of developing novel methods of upgrading low quality natural gas to meet pipeline specifications. Kvaerner Process Systems (KPS) and W. L. Gore & Associates (GORE) gas/liquid membrane contactors are based on expanded polytetrafluoroethylene (ePTFE) membranes acting as the contacting barrier between the contaminated gas stream and the absorbing liquid. These resilient membranes provide much greater surface area for transfer than other tower internals, with packing densities five to ten times greater, resulting inmore » equipment 50-70% smaller and lower weight for the same treating service. The scope of the research program is to (1) build and install a laboratory- and a field-scale gas/liquid membrane absorber; (2) operate the units with a low quality natural gas feed stream for sufficient time to verify the simulation model of the contactors and to project membrane life in this severe service; and (3) conducted an economic evaluation, based on the data, to quantify the impact of the technology. Chevron, one of the major producers of natural gas, has offered to host the test at a gas treating plant. KPS will use their position as a recognized leader in the construction of commercial amine plants for building the unit along with GORE providing the membranes. GTI will provide operator and data collection support during lab- and field-testing to assure proper analytical procedures are used. KPS and GTI will perform the final economic evaluation. GTI will provide project management and be responsible for reporting and interactions with DOE on this project. Efforts this quarter have concentrated on field site selection. ChevronTexaco has nominated their Headlee Gas Plant in Odessa, TX for a commercial-scale dehydration test. Potting and module materials testing were initiated. Preliminary

  13. GAS/LIQUID MEMBRANES FOR NATURAL GAS UPGRADING

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Howard S. Meyer

    Gas Technology Institute (GTI) is conducting this research program whose objective is to develop gas/liquid membranes for natural gas upgrading to assist DOE in achieving their goal of developing novel methods of upgrading low quality natural gas to meet pipeline specifications. Kvaerner Process Systems (KPS) and W. L. Gore & Associates (GORE) gas/liquid membrane contactors are based on expanded polytetrafluoroethylene (ePTFE) membranes acting as the contacting barrier between the contaminated gas stream and the absorbing liquid. These resilient membranes provide much greater surface area for transfer than other tower internals, with packing densities five to ten times greater, resulting inmore » equipment 50-70% smaller and lower weight for the same treating service. The scope of the research program is to (1) build and install a laboratory- and a field-scale gas/liquid membrane absorber; (2) operate the units with a low quality natural gas feed stream for sufficient time to verify the simulation model of the contactors and to project membrane life in this severe service; and (3) conducted an economic evaluation, based on the data, to quantify the impact of the technology. Chevron, one of the major producers of natural gas, has offered to host the test at a gas treating plant. KPS will use their position as a recognized leader in the construction of commercial amine plants for building the unit along with GORE providing the membranes. GTI will provide operator and data collection support during lab- and field-testing to assure proper analytical procedures are used. Kvaerner and GTI will perform the final economic evaluation. GTI will provide project management and be responsible for reporting and interactions with DOE on this project. Efforts this quarter have concentrated on field site selection. ChevronTexaco has nominated their Headlee Gas Plant in Odessa, TX for a commercial-scale dehydration test. Design and cost estimation for this new site are underway

  14. Embedded Real-Time Linux for Instrument Control and Data Logging

    NASA Technical Reports Server (NTRS)

    Clanton, Sam; Gore, Warren J. (Technical Monitor)

    2002-01-01

    When I moved to the west. coast to take a job at NASA's Ames Research Center in Mountain View, CA, I was impressed with the variety of equipment and software which scientists at the center use to conduct their research. was happy to find that I was just as likely to see a machine running Lenox as one running Windows in the offices and laboratories of NASA Ames (although many people seem to use Moos around here). I was especially happy to find that the particular group with whom I was going to work, the Atmospheric Physics Branch at Ames, relied almost entirely on Lenox machines for their day-to-day work. So it was no surprise that when it was time to construct a new control system for one of their most important pieces of hardware, a switch from an unpredictable DOS-based platform to an Embedded Linux-based one was a decision easily made. The system I am working on is called the Solar Spectral Flux Radiometer (SSFR), a PC-104 based system custom-built by Dr. Warren Gore at Ames. Dr. Gore, Dr. Peter Pilewskie, Dr. Maura Robberies and Larry Pezzolo use the SSFR in their research. The team working on the controller project consists of Dr. Gore, John Pommier, and myself. The SSFR is used by the ,cities Atmospheric Radiation Group to measure solar spectral irradiance at moderate resolution to determine the radiative effect of clouds, aerosols, and gases on climate, and also to infer the physical properties of aerosols and clouds. Two identical SSFR's have been built and successfully deployed in three field missions: 1) the Department of Energy Atmospheric Radiation Measurement (ARM) Enhanced Shortwave Experiment (ARESE) II in February/March, 2000; 2) the Puerto Rico Dust Experiment (PRIDE) in July, 2000; and 3) the South African Regional Science Initiative (SAFARI) in August/September, 2000. Additionally, the SSFR was used to acquire water vapor spectra using the Ames Diameter base-path multiple-reflection absorption cell in a laboratory experiment.

  15. Anatomic suitability of aortoiliac aneurysms for next generation branched systems.

    PubMed

    Pearce, Benjamin J; Varu, Vinit N; Glocker, Roan; Novak, Zdenek; Jordan, William D; Lee, Jason T

    2015-01-01

    Preservation of internal iliac flow is an important consideration to prevent ischemic complications during endovascular aneurysm repair. We sought to determine the suitability of aortoiliac aneurysms for off-the-shelf iliac branched systems currently in clinical trial. Patients undergoing abdominal aortic aneurysm repair from 2004 to 2013 at 2 institutions were reviewed. Centerline diameters and lengths of aortoiliac morphology were measured using three-dimensional workstations and compared with inclusion/exclusion criteria for both Cook and Gore iliac branch devices. Of the nearly 2,400 aneurysm repairs performed during the study period, 99 patients had common iliac aneurysms suitable for imaging review. Eighteen of the 99 (18.2%) patients and 25/99 (25.3%) patients fit the inclusion criteria and would have been able to be treated using the Cook and Gore iliac branch devices, respectively. The most common reason for exclusion from Cook was internal iliac diameter of <6 or >9 mm (68/99, 68.7%). The most common reason for exclusion from Gore was proximal common iliac diameter of <17 mm (39/99, 39.4%) and inadequate internal iliac artery diameter of <6.5 or >13.5 mm (37/99, 37.3%). Comparing the included patients across both devices, a total of 35/99 (35.4%) of patients would be eligible for the treatment of aortoiliac aneurysms based on anatomic criteria. Only 35% of the aneurysm repairs involving common iliac arteries would have been candidates for the 2 iliac branch devices currently in trial based on anatomic criteria. The major common reason for exclusion is the internal iliac landing zone for both devices. Design modifications for future generation iliac branch technology should focus on diameter accommodations for the hypogastric branch stent and proximal and distal sizes of the iliac branch components. Familiarity with alternate branch preserving techniques is still needed in the majority of cases. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. [Arthrodesis following revision of a knee endoprosthesis. Literature review 1984-1994].

    PubMed

    Kohn, D; Schmolke, S

    1996-04-01

    Two percent of primary and 8% of revision total knee replacements are followed by arthrodesis. Today knee arthrodesis is the most important salvage procedure after failed total knee arthroplasty, resection arthroplasty and above-the-knee amputation being the only alternatives. Analysis of the literature between 1984 and 1994 revealed 533 cases treated with arthrodesis of the knee; 403 were done after failed total knee arthroplasty. The fusion rate was 74%. External fixation, intramedullary nail, plates and combinations of these are currently used for fixation. The literature and an analysis of our own patients from 1988 to 1994 showed that arthrodesis after failed arthroplasty is a difficult procedure, and complications often occur. Bone loss of the distal femur and proximal tibia is the one most important prognostic factor. A new classification system for bone loss is presented.

  17. Ex-Vivo Cow Skin Viscoelastic Effect for Tribological Aspects in Endoprosthesis

    NASA Astrophysics Data System (ADS)

    Subhi, K. A.; Tudor, A.; Hussein, E. K.; Wahad, H.; Chisiu, G.

    2018-01-01

    The viscoelastic behavior of ex-vivo cow skin was experimentally studied by applied load from different indenter types (circle, square and triangle, all types have the same area) for different times (10 sec, 30 sec, and 60 sec). The viscoelastic tests were carried out using a UMT series (UMT-II, CETR Corporation). The experimental results collected at different operating conditions showed that the cow skin has a higher reaction against the triangle indenter compared to the other shapes. Whereas the hysteresis of cow skin was lower at low applied load time and it's increased when the time increased.

  18. [Indications for arthrodesis of the knee joint in modern orthopedics].

    PubMed

    Hart, R; Janecek, M; Bucek, P; Procházka, V; Visna, P

    2003-04-01

    Indication for arthrodesis of the knee joint is nowadays most frequently failure of a total endoprosthesis, usually septic. A less frequent indication is purulent gonitis, frequently after corticoid administration, the condition after a complicated intraarticular fracture with subsequent arthritis or oncological disease of the bones in the area of the knee joint. In the course of 2000 to 2002 at the authors' department 15 arthrodeses were implanted. In three cases the indication for arthrodesis was purulent gonitis, in three cases the condition after an open articular injury associated with infectious complications and in the remaining nine cases failure of an endoprosthesis of the knee, incl. seven caused by infection. The patients were three men and 12 women, mean age 64 years (30-75 years). For stabilization of the arthrodesis 9x external fixation was used, 5x plates and 1x intramedullary osteosynthesis. In all cases consolidation of the arthrodesis was achieved. In one case the external fixation had to be replaced by a system of two fixation devices and in one case correction of the axial position of the extremity was made. The presence of external fixation was perceived negatively in particular by female patients. Plate osteosynthesis and the use of external fixation devices are relatively quick, cheap and considerate methods of arthrodesis. External fixation must be used in acute virulent infections while plate osteosynthesis can be indicated in its absence. The characteristic of intramedullary fixation is similar, however special nails used for arthrodesis of the knee are several times more expensive than the previous types of stabilization. The advantage is the possibility to use a massive bone graft to fill the defect.

  19. A comparison of Percutaneous femoral access in Endovascular Repair versus Open femoral access (PiERO): study protocol for a randomized controlled trial.

    PubMed

    Vierhout, Bastiaan P; Saleem, Ben R; Ott, Alewijn; van Dijl, Jan Maarten; de Kempenaer, Ties D van Andringa; Pierie, Maurice E N; Bottema, Jan T; Zeebregts, Clark J

    2015-09-14

    Access for endovascular repair of abdominal aortic aneurysms (EVAR) is obtained through surgical cutdown or percutaneously. The only devices suitable for percutaneous closure of the 20 French arteriotomies of the common femoral artery (CFA) are the Prostar(™) and Proglide(™) devices (Abbott Vascular). Positive effects of these devices seem to consist of a lower infection rate, and shorter operation time and hospital stay. This conclusion was published in previous reports comparing techniques in patients in two different groups (cohort or randomized). Access techniques were never compared in one and the same patient; this research simplifies comparison because patient characteristics will be similar in both groups. Percutaneous access of the CFA is compared to surgical cutdown in a single patient; in EVAR surgery, access is necessary in both groins in each patient. Randomization is performed on the introduction site of the larger main device of the endoprosthesis. The contralateral device of the endoprosthesis is smaller. When we use this type of randomization, both groups will contain a similar number of main and contralateral devices. Preoperative nose cultures and perineal cultures are obtained, to compare colonization with postoperative wound cultures (in case of a surgical site infection). Furthermore, patient comfort will be considered, using VAS-scores (Visual analog scale). Punch biopsies of the groin will be harvested to retrospectively compare skin of patients who suffered a surgical site infection (SSI) to patients who did not have an SSI. The PiERO trial is a multicenter randomized controlled clinical trial designed to show the consequences of using percutaneous access in EVAR surgery and focuses on the occurrence of surgical site infections. NTR4257 10 November 2013, NL44578.042.13.

  20. Canine total hip replacement using a cementless threaded cup and stem: a review of 55 cases.

    PubMed

    Denny, H R; Linnell, M; Maddox, T W; Comerford, E J

    2018-06-01

    To determine the long-term results and complications associated with the Helica ® cementless hip endoprosthesis system. Retrospective study of 55 consecutive Helica total hip replacements performed between January 2010 and February 2015. A total of 55 total hip replacements were performed in 50 dogs; 45 dogs had unilateral hip replacements, and five had staged bilateral replacements. A total of 23 first-generation short femoral stems were implanted in 22 dogs, of which nine cases (39%) experienced complications and 19 (86%) recovered satisfactorily when revisions were included; 31 second-generation femoral stems were implanted in 28 dogs, of which 10 cases (32%) experienced complications, and 26 (93%) made satisfactory recoveries, including revisions. In 36 dogs for which data were available, postoperative Liverpool Osteoarthritis in Dogs scores were significantly reduced compared to preoperative scores. Complications occurred in a total of 19 cases (34·5%; 95% confidence interval: 22 to 47·1%); the most common was aseptic loosening of the femoral stem [11 cases (20%; 95% confidence interval: 9·4 to 30·6%)]. Following multivariable analysis, no risk factors were identified for overall complications, but there was a significant association of implant type (first-generation short stem) with loosening (odds ratio 4·9, 95% confidence interval: 1·1 to 22·1, P=0·034). This study found the Helica hip endoprosthesis system to be effective in the management of hip dysplasia and osteoarthritis in dogs. Aseptic loosening of the femoral stem remains the most common complication but appears to have been significantly reduced with the introduction of the second-generation stem. © 2018 British Small Animal Veterinary Association.

  1. Use of Combination Thermal Therapy and Radiation in Breast Conserving Treatment of Extensive Intraductal Breast Cancer

    DTIC Science & Technology

    1994-07-11

    Hospital (NEDH); a Harvard Medical School (HMS) affiliated hospital in Boston, Massachusetts. The program director, Goran K. Svensson, Ph.D. is an...Recipes, The Art of Scientific Computing. Cambridge University Press, 1985. 17. Recht, A., Come, S.E., Gelman, R.S., Goldstein, M., Tishler, S., Gore...of Radiation oncology, Harvard Medical School , Boston, Mh 02115 *E.C. Burdette, Dornier Medical System Inc. Champaign, IL 61820 ARTBC at the base of

  2. Experimental Facilities and Aircraft Certification, International Symposium Proceedings

    DTIC Science & Technology

    1995-08-01

    Symposium were Russian and English with providing simultaneous translation at the plenary ses- sions. The Symposium Proceedings are published in English...interstate memo- randum, signed on 30 June 1995 by V.S. Chernomyrdin and A.Gore, which was mentioned in the first part of this report. Simultaneously with this...mode by means of correction determination and trans- mission of such data to aircraft; - bench for both pilots ejection. Development of simultaneous

  3. Vigna yadavii (Leguminosae: Papilionoideae), a new species from Western Ghats, India

    PubMed Central

    Gaikwad, Sayajirao P.; Randive, Sonali D.; Garad, Krushnadeoray U.

    2014-01-01

    Abstract A new species of Vigna Savi, subgenus Ceratotropis (Piper) Verdc., Vigna yadavii S.P. Gaikwad, R.D. Gore, S.D. Randive & K.U. Garad, sp. nov. is described and illustrated here. It is morphologically close to Vigna dalzelliana (Kuntze) Verdc. but differs in its underground obligate cleistogamous flowers on positively geotropic branches, hairy calyx, small corolla, linear style beak and dimorphic seeds with shiny seed coat. PMID:25589877

  4. Maternal nodal and zebrafish embryogenesis.

    PubMed

    Bennett, James T; Stickney, Heather L; Choi, Wen-Yee; Ciruna, Brian; Talbot, William S; Schier, Alexander F

    2007-11-08

    In fish and amphibians, the dorsal axis is specified by the asymmetric localization of maternally provided components of the Wnt signalling pathway. Gore et al. suggest that the Nodal signal Squint (Sqt) is required as a maternally provided dorsal determinant in zebrafish. Here we test their proposal and show that the maternal activities of sqt and the related Nodal gene cyclops (cyc) are not required for dorsoventral patterning.

  5. [Distal stenosis of the choledochus in chronic pancreatitis: endoscopic drainage or operation?].

    PubMed

    Meyer, W; Bödeker, H; Schönekäs, H; Gebhardt, C

    1996-09-01

    With the less invasive techniques for complications regarding chronic pancreatitis, such as tubular choledochostenosis, the endoscopic transpapillary bile drainage therapy by means of endoprosthesis has undergone an enlargement of its indications range. Blocked and dislocated prostheses, however, further raise the already existing possibility of septic complications. With 15 out of 43 patients undergoing medium-term endodrainage treatment, we observed different resulting conditions of chronic cholestasis, such as abscess-forming cholangitis, hepatic abscesses, retroperitoneal phlegmon and sepsis up to biliary cirrhosis. Thus, in the case of chronic pancreatitis we still regard choledochostenosis- which, due to scarring, is mostly fixed-as a primary indication for operation.

  6. Endovascular Management of Delayed Complete Graft Thrombosis After Endovascular Aneurysm Repair

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thurley, Peter D., E-mail: pthurley@doctors.org.u; Glasby, Michael J.; Pollock, John G.

    2010-08-15

    Graft thrombosis rates after endovascular aneurysm repair (EVAR) of abdominal aortic aneurysms vary widely in published series. When thrombosis does occur, it usually involves a single limb and occurs within 3 months of stent-graft insertion. If the entire endoprosthesis is thrombosed, treatment may be challenging because femoro-femoral crossover graft insertion is not an option and a greater volume of thrombus is present, thus making thrombolysis more difficult. We present two cases of delayed thrombosis after EVAR involving the entire stent-graft. These were successfully treated by a combined surgical and endovascular technique, and patency has been maintained in both cases tomore » date.« less

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Amygdalos, Michael A.; Haskal, Ziv J.; Cope, Constantin

    Two patients with pancreatic malignancies presented with biliary obstruction which could not be treated from an endoscopic approach. Standard transhepatic biliary drainage was relatively contraindicated because of moderate ascites and coagulopathy related to underlying liver disease. In one patient, a transjugular, transvenous approach was used to deliver a Wallstent endoprosthesis across the distal common bile duct obstruction in a single step procedure. In the second case, a previously placed biliary Wallstent was revised with an additional stent from a similar approach. Transjugular biliary catheterization offers a valuable alternative approach for primary stent placement or revision in patients with contraindication tomore » standard transhepatic drainage.« less

  8. The telescoping suture--Part II: A novel method to improve the mechanical behavior of a new biomaterial: ostrich pericardium.

    PubMed

    García Páez, J M; Jorge Herrero, E; Rocha, A; Martín-Maestro, M; Castillo-Olivares, J L; Millán, I; Carrera Sanmartín, A; Cordón, A

    2002-10-01

    Ostrich pericardium, sutured using a telescoping or overlapping technique, was studied to determine its mechanical behavior. From each of 12 pericardial sacs, four contiguous strips were cut longitudinally, from root to apex, and another four contiguous strips were cut in transverse direction. One of the strips in each set of four was used as an unsutured control and the remaining three were sutured by overlapping 0.5 cm of the tissue and sewing with Gore-tex, Prolene or Pronova. These 96 samples were then subjected to tensile testing along their major axes until rupture. The tensile stresses recorded in the suture materials at the moment tears appeared in the pericardium ranged between 55.99 MPa and 70.23 MPa for Gore-tex in samples cut in the two directions. Shear stress became ostensible at 56 MPa, with clearly evident tears. However, microfracture of the collagen fibers must be produced at much lower stress levels. The comparison of the resistance in kilograms (machine-imposed), without taking into account the sections in which the load was applied, demonstrated only a slight loss of load when the telescoping suture was employed in ostrich pericardium samples. Ostrich pericardium may continue to be an alternative biological material for the construction of heart valve leaflets.

  9. Department of Defense Congressional Action on FY 1984 Authorization Request.

    DTIC Science & Technology

    1983-10-11

    AUTHORIZATION NOTE: The Military Construction Bill authorization recommendation totaIS dIO not include projects authorized using savings or authorized for...change from the request). &DE9rooi)00 ti M S in Million (Zallocki- Proc. of Ammunition. Armsy Nerve gas artillery shells .185 Bethune) Proc. of...Ammunitioin. Army Nerve gas production -96S (Gore) Missile Proc, Air Force MX Production funds -357 8 (Byron) ROTE, Air Force T-46A Trainer Aircraft . 200

  10. Air Force Sexual Assault Situations, Settings, And Offender Behaviors

    DTIC Science & Technology

    Recent high-profile reports and incidents have highlighted the ongoing problem of sexual assault within the U.S. military. For example, the 2014 RAND... experienced a sexual assault in the past year (Morral, Gore, and Schell, 2015a, p. 10). Among the women who were sexually assaulted, 82 percent indicated that...response efforts, including seeking more information about offender characteristics and behaviors and the situations and settings in which sexual assaults occur.

  11. Unfurlable satellite antennas - A review

    NASA Technical Reports Server (NTRS)

    Roederer, Antoine G.; Rahmat-Samii, Yahia

    1989-01-01

    A review of unfurlable satellite antennas is presented. Typical application requirements for future space missions are first outlined. Then, U.S. and European mesh and inflatable antenna concepts are described. Precision deployables using rigid panels or petals are not included in the survey. RF modeling and performance analysis of gored or faceted mesh reflector antennas are then reviewed. Finally, both on-ground and in-orbit RF test techniques for large unfurlable antennas are discussed.

  12. Synthetic devices for reconstructive surgery of the cruciate ligaments: a systematic review.

    PubMed

    Batty, Lachlan M; Norsworthy, Cameron J; Lash, Nicholas J; Wasiak, Jason; Richmond, Anneka K; Feller, Julian A

    2015-05-01

    The role of synthetic devices in the management of the cruciate ligament-injured knee remains controversial. The aim of this systematic review was to assess the safety and efficacy of synthetic devices in cruciate ligament surgery. A systematic review of the electronic databases Medline, Embase, and The Cochrane Library (issue 1, 2014) on January 13, 2014, was performed to identify controlled and uncontrolled trials. Trials that assessed the safety and efficacy of synthetic devices for cruciate ligament surgery were included. The main variables assessed included rates of failure, revision, and noninfective effusion and synovitis. Patient-reported outcome assessments and complications were also assessed where reported. From 511 records screened, we included 85 articles published between 1985 and 2013 reporting on 6 synthetic devices (ligament augmentation and reconstruction system [Ligament Augmentation and Reconstruction System (LARS; Surgical Implants and Devices, Arc-sur-Tille, France)]; Leeds-Keio [Xiros (formerly Neoligaments), Leeds, England]; Kennedy ligament augmentation device [3M, St Paul, MN]; Dacron [Stryker, Kalamazoo, MI]; Gore-Tex [W.L. Gore and Associates, Flagstaff, AZ]; and Trevira [Telos (limited liability company), Marburg, Germany]). The heterogeneity of the included studies precluded meta-analysis. The results were analyzed by device and then type of reconstruction (anterior cruciate ligament [ACL]/posterior cruciate ligament [PCL]/combined ACL and PCL). The lowest cumulative rates of failure were seen with the LARS device (2.6% for ACL and 1% for PCL surgery). The highest failure rate was seen in the Dacron ACL group (cumulative rate, 33.6%). Rates of noninfective synovitis and effusion ranged from 0.2% in the LARS ACL group to 27.6% in the Gore-Tex ACL group. Revision rates ranged from 2.6% (LARS) to 11.8% (Trevira-Hochfest; Telos). Recent designs, specifically the LARS, showed good improvement in the outcome scores. The mean preoperative and

  13. GAS/LIQUID MEMBRANES FOR NATURAL GAS UPGRADING

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Howard S. Meyer

    Gas Technology Institute (GTI) is conducting this research program whose objective is to develop gas/liquid membranes for natural gas upgrading to assist DOE in achieving their goal of developing novel methods of upgrading low quality natural gas to meet pipeline specifications. Kvaerner Process Systems (KPS) and W. L. Gore & Associates (GORE) gas/liquid membrane contactors are based on expanded polytetrafluoroethylene (ePTFE) membranes acting as the contacting barrier between the contaminated gas stream and the absorbing liquid. These resilient membranes provide much greater surface area for transfer than other tower internals, with packing densities five to ten times greater, resulting inmore » equipment 50-70% smaller and lower weight for the same treating service. The scope of the research program is to (1) build and install a laboratory- and a field-scale gas/liquid membrane absorber; (2) operate the units with a low quality natural gas feed stream for sufficient time to verify the simulation model of the contactors and to project membrane life in this severe service; and (3) conducted an economic evaluation, based on the data, to quantify the impact of the technology. Chevron, one of the major producers of natural gas, has offered to host the test at a gas treating plant. KPS will use their position as a recognized leader in the construction of commercial amine plants for building the unit along with GORE providing the membranes. GTI will provide operator and data collection support during lab- and field-testing to assure proper analytical procedures are used. Kvaerner and GTI will perform the final economic evaluation. GTI will provide project management and be responsible for reporting and interactions with DOE on this project. Efforts this quarter have concentrated on field site selection. ChevronTexaco has nominated their Headlee Gas Plant in Odessa, TX for a commercial-scale dehydration test. Design and cost estimation for this new site are underway. A

  14. Development of a super-pressure balloon with a diamond-shaped net --- result of a ground inflation test of a 2,000 cubic-meter balloon ---

    NASA Astrophysics Data System (ADS)

    Saito, Yoshitaka; Nakashino, Kyoichi; Akita, Daisuke; Matsushima, Kiyoho; Shimadu, Shigeyuki; Goto, Ken; Hashimoto, Hiroyuki; Matsuo, Takuma

    2016-07-01

    A light super-pressure balloon has been developed using a method to cover a balloon with a diamond-shaped net of high-tensile fibers. The goal is to fly a payload of 900 kg to the altitude of 37 km with a 300,000 m^{3} balloon. Beginning from a demonstration test of the net-balloon with a 10 m^{3} balloon in 2010, we have been polished the net-balloon through ground inflation tests and flight tests, including a flight test of a 3,000 m ^{3} balloon in the tandem balloon configuration with a 15,000 m^{3} zero-pressure balloon in 2012, and a flight test of a 10 m^{3} balloon in the tandem balloon configuration with a 2 kg rubber balloon in 2013, as reported in the last COSPAR. In 2014, we developed a 5,000 m^{3} balloon and performed a ground inflation test to find that the balloon burst from a lip panel for termination with a differential pressure of 425 Pa. It was due to a stress concentration at the edge of a thick tape attached along the termination mechanism. In 2015, we modified the balloon by adding tapes on the lip panel to avoid the stress concentration, and also shorten the net length to leave some margin of the film and performed a ground inflation test again to find the balloon showed asymmetrical deployment and burst from the edge of the net with a differential pressure of 348 Pa. We consider it is due to the margin of the film along the circumferential direction, and proposed a gore shape which circumference length is kept as determined by the pumpkin shape of the balloon but setting meridian length longer than that. We developed a 10 m^{3} balloon with the gore design to find that the balloon deployed symmetrically and showed the burst pressure of 10,000 Pa. In 2016, we are going to develop a 2,000 m^{3} balloon with the gore design and perform its ground inflation test. In this paper, we are going to report its result with the sequence of the development.

  15. Biomechanical analysis of a novel hemipelvic endoprosthesis during ascending and descending stairs.

    PubMed

    Liu, Dongxu; Hua, Zikai; Yan, Xinyi; Jin, Zhongmin

    2016-10-01

    In this study, the biomechanical characteristic of a newly developed adjustable hemipelvic prosthesis under dynamic loading conditions was investigated using explicit finite element method. Both intact and reconstructed pelvis models, including pelvis, femur and soft tissues, were established referring to human anatomic data using a solid geometry of a human pelvic bone. Hip contact forces during ascending stairs and descending stairs were imposed on pelvic models. Results showed that maximum von Mises stresses in reconstructed pelvis were 421.85 MPa for prostheses and 109.12 MPa for cortical bone, which were still within a low and elastic range below the yielding strength of Ti-6Al-4V and cortical bone, respectively. Besides, no significant difference of load transferring paths along pelvic rings was observed between the reconstructed pelvis and natural pelvis models. And good agreement was found between the overall distribution of maximum principal stresses in trabecular bones of reconstructed pelvis and natural pelvis, while at limited stances, principal stresses in trabecular bone of reconstructed pelvis were slightly lower than natural pelvis. The results indicated that the load transferring function of pelvis could be restored by this adjustable hemipelvic prosthesis. Moreover, the prosthesis was predicted to have a reliable short- and long-term performance. However, due to the occurrence of slightly lower principal stresses at a few stances, a porous structure applied on the interface between the prosthesis and bone would be studied in future work to obtain better long-term stability. © IMechE 2016.

  16. Explanting the Nellix Endovascular Aortic Sealing Endoprosthesis for Proximal Aortic Neck Failure.

    PubMed

    Lee, Cheong Jun; Cuff, Robert

    2018-05-17

    Open conversion following endovascular aortic repair (EVAR) has inherent challenges particular to the device being explanted. The Nellix endograft is unlike any other device as it utilizes polymer filling of endobags within the aorto-iliac lumen to seal the AAA sac; a developing concept known as endovascular aortic sealing (EVAS). Conversion to open repair of AAA treated with the Nellix endograft have rarely been discussed. Explants that have been previously reported were for graft infection. We present two Nellix graft explants that were required for device migration and subsequent development of a type IA endoleak. The technique and nuances observed during open conversion of this novel endograft for proximal aortic neck failure is described in this report. Copyright © 2018. Published by Elsevier Inc.

  17. [Post-traumatic arthritis in the young patient : Treatment options before the endoprosthesis].

    PubMed

    Burkhart, K J; Hollinger, B

    2016-10-01

    In the young patient, treatment of post-traumatic elbow arthritis remains difficult. Total elbow arthroplasty must be delayed for as long as possible. Therapy starts with nonoperative treatment. If this fails, operative options can be discussed. The aim of surgery is to provide a functional range of motion with acceptable pain without obstructing future treatment options. Patients with pain at terminal extension and/or flexion may benefit from arthroscopic or open debridement. Patients with advanced osteoarthritis and pain throughout the complete range of motion, who are too young for total elbow arthroplasty, are offered interposition arthroplasty or arthrodesis. Arthrodesis of the elbow leads to significant restrictions in daily life due to the complete loss of extension/flexion. Therefore, arthrodesis is only offered as treatment in exceptional circumstances. Interposition arthroplasty is a reasonable option for the young patient without significant bony defects, which may provide a stable, functional flexion arc with an acceptable pain level. Interposition arthroplasty preserves the revision options of re-interposition arthroplasty as well as the withdrawal to total elbow arthroplasty. Partial and total elbow arthroplasty are treatment options of elbow arthritis but are not subjects of this article.

  18. Causes of Warming and Thawing Permafrost in Alaska

    NASA Astrophysics Data System (ADS)

    Osterkamp, T. E.

    2007-11-01

    There is a perception that climatic warming was the cause of the twentieth-century global warming and thawing of permafrost and associated terrain instability (thermokarst) [>Gore, 2006; Perkins, 2007; Zielinski, 2007; Delisle, 2007]. While pertinent data are sparse, published results do not support this viewpoint [Zhang et al., 2001; Osterkamp, 2007]. This brief report reviews the warming of permafrost in Alaska during the twentieth century and shows that snow cover has played a significant role in it.

  19. Endovascular Treatment of an Aortoiliac Tuberculous Pseudoaneurysm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Villegas, Miguel O.; Mereles, Alberto Perez; Tamashiro, Gustavo A.

    2013-04-15

    We report a rare case of a tuberculous mycotic aortoiliac pseudoaneurysm treated with an endovascular procedure and follow-up of 36 months. The patient was a white 72-year-old man with pulmonary tuberculosis and a former smoker with hypertension, chronic renal failure, and dyslipidemia. A computed tomographic scan of the abdomen and pelvis revealed a left paravertebral cavity with fluid content and involvement of vertebrae L2-L4. After a surgical repair attempt, the patient was treated with the implant of a bifurcated endoprosthesis. Because it is unlikely that any center has extensive experience in the management of this rare manifestation of the disease,more » we reviewed the literature for similar cases.« less

  20. [Diagnosis of septic loosening of hip prosthesis with LeukoScan. SPECT scan with 99mTc-labeled monoclonal antibodies].

    PubMed

    Kaisidis, A; Megas, P; Apostolopoulos, D; Spiridonidis, T; Koumoundourou, D; Zouboulis, P; Lambiris, E; Vassilakos, P

    2005-05-01

    Diagnosis of septic loosening of hip endoprosthesis with antigranulocyte scintigraphy (AGS) was analysed. Twenty-one hip prostheses were studied using laboratory tests and, in cases of elevated values, three-phase bone scan (BS) and AGS. Elective SPECT/CT scans were performed. Histologic and microbiologic exams verified the diagnosis. The AGS analysis revealed sensitivity, specificity and accuracy of value 1, while positive and negative predictive values were also 1. BS showed sensitivity of 1 and specificity of 0.33. In three cases, SPECT/CT scans corroborated the AGS interpretation. This diagnostic algorithm proved effective in the detection of septic loosening of hip prostheses. AGS can be avoided without risk of infection being overlooked.

  1. A Modified Rabbit Ulna Defect Model for Evaluating Periosteal Substitutes in Bone Engineering: A Pilot Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    El Backly, Rania M.; IRCCS AOU San Martino–IST Istituto Nazionale per la Ricerca sul Cancro, Genova; Faculty of Dentistry, Alexandria University, Alexandria

    The present work defines a modified critical size rabbit ulna defect model for bone regeneration in which a non-resorbable barrier membrane was used to separate the radius from the ulna to create a valid model for evaluation of tissue-engineered periosteal substitutes. Eight rabbits divided into two groups were used. Critical defects (15 mm) were made in the ulna completely eliminating periosteum. For group I, defects were filled with a nanohydroxyapatite poly(ester urethane) scaffold soaked in PBS and left as such (group Ia) or wrapped with a tissue-engineered periosteal substitute (group Ib). For group II, an expanded-polytetrafluoroethylene (e-PTFE) (GORE-TEX{sup ®}) membranemore » was inserted around the radius then the defects received either scaffold alone (group IIa) or scaffold wrapped with periosteal substitute (group IIb). Animals were euthanized after 12–16 weeks, and bone regeneration was evaluated by radiography, computed microtomography (μCT), and histology. In the first group, we observed formation of radio-ulnar synostosis irrespective of the treatment. This was completely eliminated upon placement of the e-PTFE (GORE-TEX{sup ®}) membrane in the second group of animals. In conclusion, modification of the model using a non-resorbable e-PTFE membrane to isolate the ulna from the radius was a valuable addition allowing for objective evaluation of the tissue-engineered periosteal substitute.« less

  2. Criteria for evaluation of reflective surface for parabolic dish concentrators

    NASA Technical Reports Server (NTRS)

    Bouquet, F.

    1980-01-01

    Commercial, second surface glass mirror are emphasized, but aluminum and metallized polymeric films are also included. Criteria for sealing solar mirrors in order to prevent environmental degradation and criteria for bonding sagged or bent mirrors to substrate materials are described. An overview of the technical areas involved in evaluating small mirror samples, sections, and entire large gores is presented. A basis for mirror criteria was established that eventually may become part of inspection and evaluation techniques for three dimensional parabolic reflective surfaces.

  3. High Frontier, The Journal for Space & Missile Professionals. Volume 5, Number 4

    DTIC Science & Technology

    2009-08-01

    MoD Senior Responsible Owner for both Space and UAVs. He is president of RAF Rugby Union , president of the Northern Ireland Wing of the Air Training...President Bill Clinton claimed a ‘peace dividend’ after the fall of the Soviet Union . Vice President Al Gore promoted greater use by Department of...countries of the former Soviet Union . His final assignment was as the US de- fense and air attaché to Turkey where he also flew the C-12. He is a

  4. Chronic Osteomyelitis of the Distal Femur Treated with Resection and Delayed Endoprosthetic Reconstruction: A Report of Three Cases.

    PubMed

    Ryan, Sean; Eward, William; Brigman, Brian; Zura, Robert

    2017-01-01

    Chronic osteomyelitis involving the distal femur often results in amputation or arthrodesis. This article presents three cases of chronic osteomyelitis treated with a staged approach culminating in endoprosthetic reconstruction. Stage one involved resection of infected bone and placement of an intramedullary nail spanning the bony defect between proximal femur and tibia, with antibiotic cement packed around the nail. Patients were then placed on long-term IV +/- oral antibiotics to clear the infection. A "cooldown" period was then used between stages where patients were off antibiotics and inflammatory markers were monitored for signs of remaining infection. Stage two then involved reconstruction of the distal femur and knee with an endoprosthesis. In the appropriate patient, this treatment strategy offers another option in this challenging population.

  5. ChEVAS: Combining Suprarenal EVAS with Chimney Technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Torella, Francesco, E-mail: f.torella@liverpool.ac.uk; Chan, Tze Y., E-mail: tze.chan@rlbuht.nhs.uk; Shaikh, Usman, E-mail: usman.shaikh@rlbuht.nhs.uk

    2015-10-15

    Endovascular sealing with the Nellix{sup ®} endoprosthesis (EVAS) is a new technique to treat infrarenal abdominal aortic aneurysms. We describe the use of endovascular sealing in conjunction with chimney stents for the renal arteries (chEVAS) in two patients, one with a refractory type Ia endoleak and an expanding aneurysm, and one with a large juxtarenal aneurysm unsuitable for fenestrated endovascular repair (EVAR). Both aneurysms were successfully excluded. Our report confirms the utility of chEVAS in challenging cases, where suprarenal seal is necessary. We suggest that, due to lack of knowledge on its durability, chEVAS should only been considered when moremore » conventional treatment modalities (open repair and fenestrated EVAR) are deemed difficult or unfeasible.« less

  6. Petrographic Analysis of Cores from Plant 42

    DTIC Science & Technology

    2016-10-01

    ER D C TR -X X- D R AF T Petrographic Analysis of Cores from Plant 42 E n gi n ee r R es ea rc h a n d D ev el op m en t C en te r...E. Rae Reed-Gore, Kyle Klaus, and Robert D. Moser October 2016 Approved for public release; distribution is unlimited. The U.S. Army...ORIGINATOR. ii Figures and Tables Figures Figure 1. Test location map of AF Plant 42 with core number locations. ............................. 2

  7. Aerodynamic Characterization of New Parachute Configurations for Low-Density Deceleration

    NASA Technical Reports Server (NTRS)

    Tanner, Christopher L.; Clark, Ian G.; Gallon, John C.; Rivellini, Tommaso P.; Witkowski, Allen

    2013-01-01

    The Low Density Supersonic Decelerator project performed a wind tunnel experiment on the structural design and geometric porosity of various sub-scale parachutes in order to inform the design of the 110ft nominal diameter flight test canopy. Thirteen different parachute configurations, including disk-gap-band, ring sail, disk sail, and star sail canopies, were tested at the National Full-scale Aerodynamics Complex 80- by 120-foot Wind Tunnel at NASA Ames Research Center. Canopy drag load, dynamic pressure, and canopy position data were recorded in order to quantify there lative drag performance and stability of the various canopies. Desirable designs would yield increased drag above the disk-gap-band with similar, or improved, stability characteristics. Ring sail parachutes were tested at geometric porosities ranging from 10% to 22% with most of the porosity taken from the shoulder region near the canopy skirt. The disk sail canopy replaced the rings lot portion of the ring sail canopy with a flat circular disk and wastested at geometric porosities ranging from 9% to 19%. The star sail canopy replaced several ringsail gores with solid gores and was tested at 13% geometric porosity. Two disk sail configurations exhibited desirable properties such as an increase of 6-14% in the tangential force coefficient above the DGB with essentially equivalent stability. However, these data are presented with caveats including the inherent differences between wind tunnel and flight behavior and qualitative uncertainty in the aerodynamic coefficients.

  8. Comparisons of geoid models over Alaska computed with different Stokes' kernel modifications

    NASA Astrophysics Data System (ADS)

    Li, X.; Wang, Y.

    2011-01-01

    Various Stokes kernel modification methods have been developed over the years. The goal of this paper is to test the most commonly used Stokes kernel modifications numerically by using Alaska as a test area and EGM08 as a reference model. The tests show that some methods are more sensitive than others to the integration cap sizes. For instance, using the methods of Vaníček and Kleusberg or Featherstone et al. with kernel modification at degree 60, the geoid decreases by 30 cm (on average) when the cap size increases from 1° to 25°. The corresponding changes in the methods of Wong and Gore and Heck and Grüninger are only at the 1 cm level. At high modification degrees, above 360, the methods of Vaníček and Kleusberg and Featherstone et al become unstable because of numerical problems in the modification coefficients; similar conclusions have been reported by Featherstone (2003). In contrast, the methods of Wong and Gore, Heck and Grüninger and the least-squares spectral combination are stable at any modification degree, though they do not provide as good fit as the best case of the Molodenskii-type methods at the GPS/Leveling benchmarks. However, certain tests for choosing the cap size and modification degree have to be performed in advance to avoid abrupt mean geoid changes if the latter methods are applied.

  9. Long-term observations of Alaska Coastal Current in the northern Gulf of Alaska

    NASA Astrophysics Data System (ADS)

    Stabeno, Phyllis J.; Bell, Shaun; Cheng, Wei; Danielson, Seth; Kachel, Nancy B.; Mordy, Calvin W.

    2016-10-01

    The Alaska Coastal Current is a continuous, well-defined system extending for 1700 km along the coast of Alaska from Seward, Alaska to Samalga Pass in the Aleutian Islands. The currents in this region are examined using data collected at >20 mooring sites and from >400 satellite-tracked drifters. While not continuous, the mooring data span a 30 year period (1984-2014). Using current meter data collected at a dozen mooring sites spread over four lines (Seward, Gore Point, Kennedy and Stevenson Entrances, and the exit to Shelikof Strait) total transport was calculated. Transport was significantly correlated with alongshore winds, although the correlation at the Seward Line was weak. The largest mean transport in the Alaska Coastal Current occurred at Gore Point (1.4×106 m3 s-1 in winter and 0.6×106 m3 s-1 in summer), with the transport at the exit to Shelikof Strait (1.3×106 m3 s-1 in winter and 0.6×106 m3 s-1 in summer) only slightly less. The transport was modified at the Seward Line in late summer and fall by frontal undulations associated with strong river discharge that enters onto the shelf at that time of year. The interaction of the Alaska Coastal Current and tidal currents with shallow banks in the vicinity of Kodiak Archipeligo and in Kennedy-Stevenson Entrance results in mixing and prolonged primary production throughout the summer.

  10. Advanced solar concentrator mass production, operation, and maintenance cost assessment

    NASA Technical Reports Server (NTRS)

    Niemeyer, W. A.; Bedard, R. J.; Bell, D. M.

    1981-01-01

    The object of this assessment was to estimate the costs of the preliminary design at: production rates of 100 to 1,000,000 concentrators per year; concentrators per aperture diameters of 5, 10, 11, and 15 meters; and various receiver/power conversion package weights. The design of the cellular glass substrate Advanced Solar Concentrator is presented. The concentrator is an 11 meter diameter, two axis tracking, parabolic dish solar concentrator. The reflective surface of this design consists of inner and outer groups of mirror glass/cellular glass gores.

  11. Ocean management plan includes array of recommendations

    NASA Astrophysics Data System (ADS)

    Showstack, Randy

    When U.S. President Bill Clinton and Vice President Al Gore appeared in Monterey, California in June 1998 for a National Oceans Conference, some of the salt water spray from the Pacific Ocean must have clung to them.As a follow-up to the conference, the Clinton Administration on September 2 issued an interagency report to help guide federal efforts in establishing a comprehensive ocean policy.The report, which touches upon a number of global issues including the United Nations Convention on the Law of the Sea, contains nearly 150 recommendations.

  12. An occurrence of metastable cristobalite in high-pressure garnet Granulite

    USGS Publications Warehouse

    Darling, R.S.; Chou, I.-Ming; Bodnar, R.J.

    1997-01-01

    High-pressure (0.8 gigapascals) granulite facies garnet from Gore Mountain, New York, hosts multiple solid inclusions containing the low- pressure silica polymorph cristobalite along with albite and minor ilmenite. Identification of cristobalite is based on Raman spectra, electron microprobe analysis, and microthermometric measurements on the ??/?? phase transformation. The cristobalite plus albite inclusions may have originated as small, trapped samples of hydrous sodium-aluminum-siliceous melt. Diffusive loss of water from these inclusions under isothermal, isochoric conditions may have resulted in a large enough internal pressure decrease to promote the metastable crystallization of cristobalite.

  13. Assessment of surface-water quantity and quality, Eagle River watershed, Colorado, 1947-2007

    USGS Publications Warehouse

    Williams, Cory A.; Moore, Jennifer L.; Richards, Rodney J.

    2011-01-01

    The spatial patterns for concentrations of trace metals (aluminum, cadmium, copper, iron, manganese, and zinc) indicate an increase in dissolved concentrations of these metals near historical mining areas in the Eagle River and several tributaries near Belden. In general, concentrations decrease downstream from mining areas. Concentrations typically are near or below reporting limits in Gore Creek and other tributaries within the watershed. Concentrations for trace elements (arsenic, selenium, and uranium) in the watershed usually are below the reporting limit, and no prevailing spatial patterns were observed in the data. Step-trend analysis and temporal-trend analysis provide evidence that remediation of historical mining areas in the upper Eagle River have led to observed decreases in metals concentrations in many surface-waters. Comparison of pre- and post-remediation concentrations for many metals indicates significant decreases in metals concentrations for cadmium, manganese, and zinc at sites downstream from the Eagle Mine Superfund Site. Some sites show order of magnitude reductions in median concentrations between these two periods. Evaluation of monotonic trends for dissolved metals concentrations show downward trends at numerous sites in, and downstream from, historic mining areas. The spatial pattern of nutrients shows lower concentrations on many tributaries and on the Eagle River upstream from Red Cliff with increases in nutrients downstream of major urban areas. Seasonal variations show that for many nutrient species, concentrations tend to be lowest May-June and highest January-March. The gradual changes in concentrations between seasons may be related to dilution effects from increases and decreases in streamflow. Upward trends in nutrients between the towns of Gypsum and Avon were detected for nitrate, orthophosphate, and total phosphorus. An upward trend in nitrite was detected in Gore Creek. No trends were detected in un-ionized ammonia within

  14. Thermal stress in seven types of chemical defense ensembles during moderate exercise in hot environments. Final report, May 1991-July 1992

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bomalaski, S.H.; Hengst, R.; Constable, S.H.

    United States Air Force -(USAF) personnel must perform their duties in many operational environments, including those with the potential for contamination with toxic chemical warfare (CW) agents. This study evaluated the physiological response to thermal stress in subjects performing moderate work in current and prototype chemical protective garments including the Battle Dress Overgarment (BDO)+BDU, BDO without BDU, United Kingdom (UK) undercoverall+BDU, Gore-Tex rainsuit+PJ-7 undercoverall, Marine Light Fighter Suit (MLFS), CWU77P, PJ-7 alone, and the BDU alone. Experimental conditions were dry bulb temperature of 40 deg C (104 deg F), a wet bulb temperature of 270C (80.6 deg F), and amore » black globe temperature of 450C (113 deg F). Eleven subjects walked on a treadmill at 3 mph with a 5% grade incline until rectal temperature (Tre) rose 1.5 deg C (2.7 deg F) above the starting value. Heart rate, rectal and mean skin temperature, and body heat storage were monitored continuously. Sweat evaporation and production were determined from the differences between pre- and postexperiment clothed and nude weights. Significantly longer work times, lower heart rates, lower Tmsk, and lower heat storage, were seen in the group comprised of the BDU, MLFS, CWU-77P, and PJ-7 compared to the Gore-Tex with PJ-7, UK plus BD BDO+BDU, and BDO no BDU ensembles. Suits which resulted in shorter tolerance times also caused rates of sweat production and lower % sweat evaporation than the less physiologically burdensome suits. Chemical protective ensembles, Thermal stress, Clothing, Exercise.« less

  15. Penile Prosthesis Implantation in Patients with a History of Total Phallic Construction.

    PubMed

    Zuckerman, Jack M; Smentkowski, Katherine; Gilbert, David; Storme, Oscar; Jordan, Gerald; Virasoro, Ramon; Tonkin, Jeremy; McCammon, Kurt

    2015-12-01

    Outcomes following penile prosthesis implantation in patients with a history of total phallic construction are not well described. The aim of this study was to evaluate outcomes following neophallus penile prosthesis placement. Retrospective review penile prosthesis placement in patients with prior total phallic construction. GORE-TEX® (Gore Medical, Flagstaff, AZ) sleeve neotunica construction was utilized in all patients. Success defined as patient sexual activity with a functioning prosthesis. Thirty-one patients underwent neophallic prosthesis implantation at a mean 35.6 years of age. Prosthesis placement occurred at an average 56.3 months following phallic construction and follow-up was a mean of 59.7 months. Malleable prostheses were placed in 21 patients and inflatable in 10; implants were bilateral in 94%. Six percent experienced operative complications including a bladder injury (1) and phallic flap arterial injury (1). Postoperative complications occurred in 23% at a median 5.5 months following placement. Five prostheses were explanted secondary to infection or erosion and two additional required revisions. Of the explanted prosthesis two were later replaced without further complication. Eighty-one percent of patients were sexually active following prosthesis placement. Penile prosthesis placement is possible in patients with prior penile reconstruction/phallic construction. Although complications rates appear to be elevated in this population compared with historic controls of normal anatomic men, the majority of patients in this series were sexually active following prosthesis placement. This demonstrates the utility of prosthesis implantation in these difficult patients. © 2015 International Society for Sexual Medicine.

  16. GPS Ocean Reflection Experiment (GORE) Wind Explorer (WindEx) Instrument Design and Development

    NASA Astrophysics Data System (ADS)

    Ganoe, G.

    2004-12-01

    This paper describes the design and development of the WindEx instrument, and the technology implemented by it. The important design trades will be covered along with the justification for the options selected. An evaluation of the operation of the instrument, and plans for continued development and enhancements will also be given. The WindEx instrument consists of a processor that receives data from an included GPS Surface reflection receiver, and computes ocean surface wind speeds in real time utilizing an algorithm developed at LaRC by Dr. Stephen J. Katzberg. The WindEx performs a windspeed server function as well as acting as a repository for the client moving map applications, and providing a web page with instructions on the installation and use of the WindEx system. The server receives the GPS reflection data produced by the receiver, performs wind speed processing, then makes the wind speed data available as a moving map display to requesting client processors on the aircraft network. The client processors are existing systems used by the research personnel onboard. They can be configured to be WINDEX clients by downloading the Java client application from the WINDEX server. The client application provides a graphical display of a moving map that shows the aircraft position along with the position of the reflection point from the surface of the ocean where the wind speed is being estimated, and any coastlines within the field of view. Information associated with the reflection point includes the estimated wind speed, and a confidence factor that gives the researcher an idea about the reliability of the wind speed measurement. The instrument has been installed on one of NOAA's Hurricane Hunters, a Gulfstream IV, whose nickname is "Gonzo". Based at MacDill AFB, Florida, "Gonzo" flies around the periphery of the storm deploying GPS-based dropsondes which measure local winds. The dropsondes are the "gold-standard" for determining surface winds, but can only be deployed sparingly. The GPS WindEx system allows for a continuous map between dropsonde releases as well as monitoring the ocean surface for suspicious areas. The GPS technique is insensitive to clouds or rain and can give information concerning surface conditions not available to the flight crew.

  17. Al Gore did Not Invent the Internet, Hans Christian Oersted did in 1820

    NASA Astrophysics Data System (ADS)

    Roberts, James; Anand, Aman; Dahiya, Jai

    2009-04-01

    In this talk it will be shown how the simple process of a current in a wire producing ``action at a distance'' in a compass can lead to development of the telegraph, telephone, wireless communication and finally to the internet. This discovery led to the invention of a motor and an electric generator. Such simple discoveries often have profound effects on what we are able to do. A discussion of how activities based on this discovery are being used in the Regional Collaborative for Excellence in Science Teaching UNT to engage students and teachers in science activities. Hand out materials will be provided to the audience on these activities.

  18. Tricuspid Valve Repair in Infancy Using Neochordae: Three-Dimensional Echocardiographic Imaging.

    PubMed

    Martin, Billie-Jean; Khoo, Nee S; Smallhorn, Jeffrey; Aklabi, Mohammed Al

    2017-11-01

    Tricuspid regurgitation (TR) in infancy poses a surgical challenge. Both two- and three-dimensional echocardiography (3DE) can provide detailed information about the mechanism(s) of valve failure and insights into valve adaptation during follow-up. We report two patients who underwent tricuspid valve repair using Gore-Tex neochordae, repairs which were facilitated by and assessed with 3DE. Both infants had less than mild residual TR and no valve tethering at hospital discharge. Furthermore, follow-up 3DEs have helped to confirm valve competence, lack of tethering, and growth of the valve and valve apparatus.

  19. Evaluating Nextgen Closely Spaced Parallel Operations Concepts with Validated Human Performance Models: Flight Deck Guidelines

    NASA Technical Reports Server (NTRS)

    Hooey, Becky Lee; Gore, Brian Francis; Mahlstedt, Eric; Foyle, David C.

    2013-01-01

    The objectives of the current research were to develop valid human performance models (HPMs) of approach and land operations; use these models to evaluate the impact of NextGen Closely Spaced Parallel Operations (CSPO) on pilot performance; and draw conclusions regarding flight deck display design and pilot-ATC roles and responsibilities for NextGen CSPO concepts. This document presents guidelines and implications for flight deck display designs and candidate roles and responsibilities. A companion document (Gore, Hooey, Mahlstedt, & Foyle, 2013) provides complete scenario descriptions and results including predictions of pilot workload, visual attention and time to detect off-nominal events.

  20. Biliary Endoprosthesis: A Prospective Analysis of Bacterial Colonization and Risk Factors for Sludge Formation

    PubMed Central

    Schneider, Jochen; Hapfelmeier, Alexander; Fremd, Julia; Schenk, Philipp; Obermeier, Andreas; Burgkart, Rainer; Forkl, Stefanie; Feihl, Susanne; Wantia, Nina; Neu, Bruno; Bajbouj, Monther; von Delius, Stefan; Schmid, Roland M.; Algül, Hana; Weber, Andreas

    2014-01-01

    Bacterial colonization of biliary stents is one of the driving forces behind sludge formation which may result in stent occlusion. Major focus of the study was to analyze the spectrum and number of microorganisms in relation to the indwelling time of stents and the risk factors for sludge formation. 343 stents were sonicated to optimize the bacterial release from the biofilm and identified by matrix-associated laser desorption/ionization-time of flight mass spectrometer (MALDI-TOF). 2283 bacteria were analyzed in total. The most prevalent microorganisms were Enterococcus species (spp.) (504;22%), followed by Klebsiella spp. (218;10%) and Candida spp. (188;8%). Colonization of the stents mainly began with aerobic gram-positive bacteria (43/49;88%) and Candida spp. (25/49;51%), whereas stents with an indwelling time>60 days(d) showed an almost equal colonization rate by aerobic gram-negative (176/184;96%) and aerobic gram-positive bacteria (183/184;99%) and a high proportion of anaerobes (127/184;69%). Compared to stents without sludge, more Clostridium spp. [(P = 0.02; Odds Ratio (OR): 2.4; 95% confidence interval (95%CI): (1.1–4.9)]) and Staphylococcus spp. [(P = 0.03; OR (95%CI): 4.3 (1.1–16.5)] were cultured from stents with sludge. Multivariate analysis revealed a significant relationship between the number of microorganisms [P<0.01; OR (95%CI): 1.3(1.1–1.5)], the indwelling time [P<0.01; 1–15 d vs. 20–59 d: OR (95%CI): 5.6(1.4–22), 1–15 d vs. 60–3087 d: OR (95% CI): 9.5(2.5–35.7)], the presence of sideholes [P<0.01; OR (95%CI): 3.5(1.6–7.9)] and the occurrence of sludge. Stent occlusion was found in 70/343(20%) stents. In 35% of cases, stent occlusion resulted in a cholangitis or cholestasis. In conclusion, microbial colonization of the stents changed with the indwelling time. Sludge was associated with an altered spectrum and an increasing number of microorganisms, a long indwelling time and the presence of sideholes. Interestingly, stent occlusion did not necessarily lead to a symptomatic biliary obstruction. PMID:25314593

  1. Early follow-up of a custom non-fluted diaphyseal press-fit tumour prosthesis.

    PubMed

    O'Donnell, Patrick W; Griffin, Anthony M; Eward, William C; Sternheim, Amir; Wunder, Jay S; Ferguson, Peter C

    2014-01-01

    The objective of this study was to evaluate the early results of a custom non-fluted diaphyseal press-fit stem for use with the global modular replacement system (GMRS) tumour prosthesis and the early complications associated with this implant. A total of 53 patients (54 implants) were identified from a prospective database where a custom non-fluted diaphyseal press-fit stem was used as part of the reconstruction of the limb. All patients had a minimum of 22 months of follow-up. The rates of stem revision for any reason were calculated. The median follow-up was 36 months (range 22-85 months). Aseptic loosening was not observed in any patient. At early term follow-up, an uncemented non-fluted stem used with the GMRS tumour endoprosthesis provides a stable bone-prosthesis interface with no evidence of aseptic loosening.

  2. [On the history of cementless implants in extremity surgery].

    PubMed

    Dufek, Pavel

    2017-05-01

    The aim of implantation of cementless hip prostheses is vital ingrowth of bone into the structured metal surface of the implant. Since the 1960s several implants with surfaces made of cobalt-based alloys have been produced for this purpose. In the 1980s a novel hip endoprosthesis with a spongiosa-metal surface was introduced. The three-dimensional ingrowth of bone tissue into the structured surface of the implant could be demonstrated both histologically and using scanning electron microscopy (SEM). These implants made of cobalt-based alloys can also be used in endo-exo prostheses. Titanium implants with a microstructured surface have also been used and very good osseintegration of the surface was also demonstrated by histomorphology. The optimization of the surface and design of the prostheses plays an increasingly more important role in the field of revision endoprostheses.

  3. Nano-ADEPT Aeroloads Wind Tunnel Test

    NASA Technical Reports Server (NTRS)

    Smith, Brandon; Yount, Bryan; Kruger, Carl; Brivkalns, Chad; Makino, Alberto; Cassell, Alan; Zarchi, Kerry; McDaniel, Ryan; Ross, James; Wercinski, Paul; hide

    2016-01-01

    A wind tunnel test of the Adaptable Deployable Entry and Placement Technology (ADEPT) was conducted in April 2015 at the US Army's 7 by10 Foot Wind Tunnel located at NASA Ames Research Center. Key geometric features of the fabric test article were a 0.7 meter deployed base diameter, a 70 degree half-angle forebody cone angle, eight ribs, and a nose-to-base radius ratio of 0.7. The primary objective of this wind tunnel test was to obtain static deflected shape and pressure distributions while varying pretension at dynamic pressures and angles of attack relevant to entry conditions at Earth, Mars, and Venus. Other objectives included obtaining aerodynamic force and moment data and determining the presence and magnitude of any dynamic aeroelastic behavior (buzz/flutter) in the fabric trailing edge. All instrumentation systems worked as planned and a rich data set was obtained. This paper describes the test articles, instrumentation systems, data products, and test results. Four notable conclusions are drawn. First, test data support adopting a pre-tension lower bound of 10 foot pounds per inch for Nano-ADEPT mission applications in order to minimize the impact of static deflection. Second, test results indicate that the fabric conditioning process needs to be reevaluated. Third, no flutter/buzz of the fabric was observed for any test condition and should also not occur at hypersonic speeds. Fourth, translating one of the gores caused ADEPT to generate lift without the need for a center of gravity offset. At hypersonic speeds, the lift generated by actuating ADEPT gores could be used for vehicle control.

  4. KSC-2015-1314

    NASA Image and Video Library

    2015-02-08

    Sen. Bill Nelson, left, and former Vice President Al Gore greet singer Jimmy Buffett, right, at NASA’s Kennedy Space Center in Florida prior to the planned liftoff of NOAA’s Deep Space Climate Observatory mission, or DSCOVR. DSCOVR will launch aboard a SpaceX Falcon 9 rocket. The mission is a partnership between NOAA, NASA and the U.S. Air Force. DSCOVR will maintain the nation's real-time solar wind monitoring capabilities which are critical to the accuracy and lead time of NOAA's space weather alerts and forecasts. To learn more about DSCOVR, visit http://www.nesdis.noaa.gov/DSCOVR. Photo credit: NASA/Kim Shiflett

  5. KSC-2015-1312

    NASA Image and Video Library

    2015-02-08

    CAPE CANAVERAL, Fla. – Former Vice President Al Gore speaks to news media at NASA’s Kennedy Space Center in Florida prior to the planned liftoff of NOAA’s Deep Space Climate Observatory spacecraft, or DSCOVR. DSCOVR will launch aboard a SpaceX Falcon 9 rocket. The mission is a partnership between NOAA, NASA and the U.S. Air Force. DSCOVR will maintain the nation's real-time solar wind monitoring capabilities which are critical to the accuracy and lead time of NOAA's space weather alerts and forecasts. To learn more about DSCOVR, visit http://www.nesdis.noaa.gov/DSCOVR. Photo credit: NASA/Kim Shiflett

  6. Large inflated-antenna system

    NASA Technical Reports Server (NTRS)

    Hinson, W. F.; Keafer, L. S.

    1984-01-01

    It is proposed that for inflatable antenna systems, technology feasibility can be demonstrated and parametric design and scalability (scale factor 10 to 20) can be validated with an experiment using a 16-m-diameter antenna attached to the Shuttle. The antenna configuration consists of a thin film cone and paraboloid held to proper shape by internal pressure and a self-rigidizing torus. The cone and paraboloid would be made using pie-shaped gores with the paraboloid being coated with aluminum to provide reflectivity. The torus would be constructed using an aluminum polyester composite that when inflated would erect to a smooth shell that can withstand loads without internal pressure.

  7. KSC-04pd1200

    NASA Image and Video Library

    2004-05-18

    KENNEDY SPACE CENTER, FLA. -- Astronaut Dom Gorie joins faculty members of Trojan Intermediate School in Potosi, Mo., for a photo. Students from three area schools — Potosi High School, John Evans Middle School and Trojan — are on a team taking part in NASA’s Explorer Schools program. KSC Deputy Director Dr. Woodrow Whitlow and Gore are sharing America’s new vision for space exploration with the next generation of explorers. They are talking with students about our destiny as explorers, NASA’s stepping stone approach to exploring Earth, the Moon, Mars and beyond, how space impacts our lives, and how people and machines rely on each other in space.

  8. Total Artificial Heart as Rescue Therapy for Primary Graft Failure in an Infant.

    PubMed

    Ziegler, Luke A; Sainathan, Sandeep; Morell, Victor O; Sharma, Mahesh S

    2018-04-01

    An infant unable to be weaned from cardiopulmonary bypass after orthotopic heart transplantation was cannulated for extracorporeal membrane oxygenation. During the next 3 days, allograft failure and intracardiac thrombosis necessitated cardiectomy. To provide acute mechanical circulatory support, artificial atrial chambers were constructed with Gore-Tex conduits and PediMag centrifugal pumps were connected to each by Berlin Heart EXCOR cannulae. The PediMag pumps were subsequently exchanged for 10-mL Berlin Heart EXCOR pumps. After 60 days of support by total artificial heart, the patient was bridged successfully to a second heart transplant. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  9. Loop technique.

    PubMed

    Seeburger, Joerg; Noack, Thilo; Winkfein, Michael; Ender, Joerg; Mohr, Friedrich Wilhelm

    2010-01-01

    The loop technique facilitates mitral valve repair for leaflet prolapse by implantation of Gore-Tex neo-chordae. The key feature of the technique is a premade bundle of four loops made out of one suture. The loops are available in different lengths ranging from 10 to 26 mm. After assessment of the ideal length of neo-chordae with a caliper the loops are then secured to the body of the papillary muscle over an additional felt pledget. In the following step, the free ends of the loops are distributed along the free margin of the prolapsing segment using one additional suture for each loop.

  10. KSC-04PD-1199

    NASA Technical Reports Server (NTRS)

    2004-01-01

    KENNEDY SPACE CENTER, FLA. -- A reporter from KJFF radio interviews astronaut Dom Gorie after his presentation at Trojan Intermediate School in Potosi, Mo. Students from three area schools Potosi High School, John Evans Middle School and Trojan are on a team taking part in NASAs Explorer Schools program. KSC Deputy Director Dr. Woodrow Whitlow and Gore are sharing Americas new vision for space exploration with the next generation of explorers. They are talking with students about our destiny as explorers, NASAs stepping stone approach to exploring Earth, the Moon, Mars and beyond, how space impacts our lives, and how people and machines rely on each other in space.

  11. Non-surgical biliary drainage - technique, indications and results.

    PubMed

    Riemann, J F; Lux, G; Rösch, W; Beickert-Sterba, A

    1981-07-01

    Nonsurgical biliary drainage offers a therapeutic alternative in the palliation of malignant obstructive jaundice. Two basic approaches are available. The percutaneous transhepatic method can be employed either for external drainage or for the placement of an internal endoprosthesis. In the case of the transduodenal, transpapillary approach, either a pigtail catheter can be placed, after prior papillotomy, or - with or without the need to split the papillar - a nasobiliary drainage tube can be introduced. Successful drainage was achieved in 67 patients. In the majority of cases, external drainage was performed as a palliative measure in inoperable carcinoma of the biliodigestive system. In addition, however, pre-operative temporary drainage was also carried out to reduce the risks of surgery in patients with severe obstructive jaundice. The complication rate was low. Apart from biliary peritonitis, cholangitis and minor bleeds were observed. The rate of failure for technical reasons was a relatively low 10%.

  12. Structural Analysis of NASA's ULDB using Photogrammetric Measurements

    NASA Astrophysics Data System (ADS)

    Young, Leyland; Garde, Gabriel; Cathey, Henry

    the final deployment stages. In time, there is no doubt that an analytical tool will be available to fully analyze the ULDB for all concerns; however, at the present time, the analytical efforts are ongoing but are delayed by the complexity of modeling a balloon from un-deployed to deployed configuration. Thus, in the absence of an analytical tool, the development of the ULDB was steered towards more experimental work in understanding the clefting phenomena. This paper highlights the experimental analyses conducted on several scaled model ULDB's using photogrammetry measurements. The experimental work began with two 48-gore 4-meter diameter scaled ULDB's having the characteristics of a 180-degree bulge angle and 7.5-degree bulge angle respectively. The 180-degree balloon inflation experiments showed that similes of clefts appeared in the balloon at the onset of full deployment; whereas, these cleft-like formations were absent in the subsequent experiments with the 7.5-degree bulge angle balloon. This confirmed the thought that "excess material" designed in the gore width to create a 180-degree bulge angle is likely contributing to the clefting phenomena. Thus, the ULDB project decided to build three 200-gore 27-meter balloons: a 90-degree bulge angle, a 55- degree bulge angle, and a 1.8-degree bulge angle balloon to verify the hypothesis of excess material contribution to the clefting phenomena and to explore the limits of the deployment trade space. The experimental analysis with photogrammetry of these three 27-meter diameter balloons provided valuable data of stresses and strains and of the deployment mechanics of an ULDB that proves excess material is a contributor to the clefting phenomena. Significantly, the photogrammetry data showed that there are significant benefits for the lower value lobe angle designs; moreover, the lower value lobe angle balloon deployed better and had stresses and strains comparable to the other two designs. Another test was conducted

  13. Minimally invasive retrieval of a dislodged Wallstent endoprosthesis after an endovascular abdominal aortic aneurysm repair.

    PubMed

    Lam, Russell C; Rhee, Soo J; Morrissey, Nicholas J; McKinsey, James F; Faries, Peter L; Kent, K Craig

    2008-02-01

    Endovascular abdominal aortic aneurysm repair (EVAR) is being performed more frequently in patients with concomitant iliac artery occlusive disease. We report a case of a 70-year-old male status post angioplasty and stenting of bilateral iliac arteries for occlusive disease who subsequently underwent EVAR for a rapidly expanding abdominal aortic aneurysm (AAA). One month after the placement of the endograft, it was discovered that the previously placed Wallstent had been dislodged during the endovascular abdominal aortic aneurysm repair. Minimally invasive retrieval using an Amplatz Goose Neck Snare was successful in recovering the stent. This case underscores the danger of performing EVAR in the setting of prior iliac artery stenting and the potential complications that may ensue.

  14. Histologic and biomechanical evaluation of a novel macroporous polytetrafluoroethylene knit mesh compared to lightweight and heavyweight polypropylene mesh in a porcine model of ventral incisional hernia repair.

    PubMed

    Melman, L; Jenkins, E D; Hamilton, N A; Bender, L C; Brodt, M D; Deeken, C R; Greco, S C; Frisella, M M; Matthews, B D

    2011-08-01

    To evaluate the biocompatibility of heavyweight polypropylene (HWPP), lightweight polypropylene (LWPP), and monofilament knit polytetrafluoroethylene (mkPTFE) mesh by comparing biomechanics and histologic response at 1, 3, and 5 months in a porcine model of incisional hernia repair. Bilateral full-thickness abdominal wall defects measuring 4 cm in length were created in 27 Yucatan minipigs. Twenty-one days after hernia creation, animals underwent bilateral preperitoneal ventral hernia repair with 8 × 10 cm pieces of mesh. Repairs were randomized to Bard(®)Mesh (HWPP, Bard/Davol, http://www.davol.com), ULTRAPRO(®) (LWPP, Ethicon, http://www.ethicon.com), and GORE(®)INFINIT Mesh (mkPTFE, Gore & Associates, http://www.gore.com). Nine animals were sacrificed at each timepoint (1, 3, and 5 months). At harvest, a 3 × 4 cm sample of mesh and incorporated tissue was taken from the center of the implant site and subjected to uniaxial tensile testing at a rate of 0.42 mm/s. The maximum force (N) and tensile strength (N/cm) were measured with a tensiometer, and stiffness (N/mm) was calculated from the slope of the force-versus-displacement curve. Adjacent sections of tissue were stained with hematoxylin and eosin (H&E) and analyzed for inflammation, fibrosis, and tissue ingrowth. Data are reported as mean ± SEM. Statistical significance (P < 0.05) was determined using a two-way ANOVA and Bonferroni post-test. No significant difference in maximum force was detected between meshes at any of the time points (P > 0.05 for all comparisons). However, for each mesh type, the maximum strength at 5 months was significantly lower than that at 1 month (P < 0.05). No significant difference in stiffness was detected between the mesh types or between timepoints (P > 0.05 for all comparisons). No significant differences with regard to inflammation, fibrosis, or tissue ingrowth were detected between mesh types at any time point (P > 0.09 for all comparisons). However, over time

  15. Withstand pressure of a simple fibrin glue sealant: experimental study of mimicked sellar reconstruction in extended transsphenoidal surgery.

    PubMed

    Oshino, Satoru; Saitoh, Youichi; Yoshimine, Toshiki

    2010-06-01

    To examine the strength and tolerance of the fibrin glue sealant in a situation of extended transsphenoidal surgery. The withstand pressure of fibrin glue sealant was measured using a simple sellar reconstruction model. A 15-mm diameter hole at the bottom of a 51-cm high cylinder was covered with a Gore-Tex (Gore-Tex, Tokyo, Japan) sheet. A small plate was placed on the center for a brief fixation, and 3 mL of fibrin glue was applied over the entire bottom. Then water was gradually filled in five cylinders, and the water level at leakage was measured as withstand pressures at 10 minutes and 24 hours after sealant application. The stability of the sealant under pressures of 20 and 30 cm H(2)O for 12 hours was also examined. The median initial withstand pressure at 10 minutes was 32 cm H(2)O (n = 5), and was significantly increased to 47.5 cm H(2)O after 24 hours (n = 4). In four of five cylinders, fibrin glue sealants were stable against a pressure of 20 cm H(2)O for 12 hours and 30 cm H(2)O for the next 12 hours. The withstand pressure of simple fibrin glue sealant without other biological reactions could be estimated to be more than 20 cm H(2)O after application, and increased to more than 40 cm H(2)O after 24 hours. These data are practical for neurosurgeons to comprehend the strength and limit of fibrin glue sealant and suggests the importance to control the intracranial pressure to less than 20 cm H(2)O, especially for the first 12 to 24 hours. Copyright © 2010 Elsevier Inc. All rights reserved.

  16. Arteriovenous Hybrid Graft with Outflow in the Proximal Axillary Vein.

    PubMed

    Murga, Allen G; Chiriano, Jason; Kiang, Sharon C; Patel, Sheela; Bianchi, Christian; Abou-Zamzam, Ahmed M; Teruya, Theodore H

    2017-07-01

    The patency of long-term hemodialysis access in end-stage renal disease patients remains a significant challenge. Often these patients are affected with limited venous outflow options, requiring limb abandonment, and creation of new access in the contralateral arm. Vascular surgeons are familiar with the exposure of the proximal axillary artery via an infraclavicular incision. The axillary vein is easily exposed through this technique. The use of the hybrid Gore graft can make the venous anastomosis easier. A hybrid graft with its venous outflow placed in the proximal axillary vein can extend the options of upper extremity access procedures. We reviewed our early experience with this technique. A review of dialysis procedures at the Loma Linda VA was performed. All patients undergoing placement of arteriovenous grafts utilizing the Gore hybrid placed into the proximal axillary vein for outflow were identified. Outcomes in terms of primary and secondary patency rates were determined. Eight patients had placement of an arteriovenous hybrid graft in the proximal axillary vein via an infraclavicular incision. All patients had exhausted other options for hemodialysis access in the ipsilateral upper extremity. All grafts were used successfully for dialysis. The mean primary and secondary patency rates at 6 months were 37.5% and 62.5%, respectively. One patient developed steal syndrome, requiring proximalization of the graft. Seven out of the 8 patients required secondary procedures including thrombectomy (n = 16) and angioplasty (n = 17). Placement of a hybrid graft in the proximal axillary vein is an effective and suitable option for patients who have exhausted arteriovenous access sites in the arm. This procedure can easily be performed in an outpatient setting with a low complication rate and allowing for preservation of the contralateral upper extremity for future use. Published by Elsevier Inc.

  17. Silicone-Polytetrafluoroethylene Composite Implants for Asian Rhinoplasty.

    PubMed

    Zelken, Jonathan A; Hong, Joon Pio; Chang, Chun-Shin; Hsiao, Yen-Chang

    2017-02-01

    Silicone and Gore-Tex implants are mainstays of Asian rhinoplasty. Silicone implants are inexpensive and wieldy, but may elicit a foreign-body reaction and are prone to migration. Gore-Tex implants are more biocompatible and capable of ingrowth but expensive. Silicone-polytetrafluoroethylene (PTFE) composites have a silicone core and PTFE liner. Composite implants have been marketed for several years, but are not yet established alternatives for rhinoplasty because of a lack of relevant reports. From February 2012 to June 2015, 177 Asian patients underwent primary (n = 63) or secondary (n = 114) rhinoplasty using an I-shaped composite implant. One hundred fifty-nine women and 18 men were 19 to 72 years old (mean, 34 years) at the time of surgery. Composite implants were 1.5 to 5 mm thick and 3.8 to 4.5 cm long. Autologous cartilage from the septum, concha, or both was used for tip refinement in every case. Glabellar augmentation was performed in 19 (10.7%) cases. Follow-up was 6.0 months (range, 1-36 months). There were 19 (10.7%) complications including malposition/deviation (4.5%), erythema (2.3%), and infection (1.1%). Four patients were unsatisfied, citing inadequate dorsal height correction. There was an 8.8% revision rate; 7 of 12 revisions were for malposition/deviation. We did not observe implant step-offs or extrusion. There were no differences in outcomes after primary or secondary rhinoplasty, although there was a trend toward higher infection rate after primary rhinoplasty (P = 0.06). I-shaped silicone-PTFE composite implants are feasible for both primary and secondary augmentation rhinoplasty in Asians. Early outcomes data suggest an overall complication rate that is comparable to PTFE alone.

  18. A comparison of finite element and test results on the vibration and damping characteristics of laminated cylinders

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roberts, J.C.; Schaefer, E.D.

    1994-12-31

    Numerical and experimental tests were performed on three thin-wall carbon fabric/epoxy cylinders with end flanges, and their vibration characteristics were compared. Two different laminates with [(0{degree})]{sub s}-2 ply and [(0{degree})]{sub 3}-3 ply configurations were used. All cylinders were fabricated using four gore sections per ply. One of the two 3-ply configurations was fabricated with the gore sections butted together, and the other with the sections overlapped approximately 6 mm. There was very little difference in the natural frequencies from tests with butted or overlapped ply joints. However, there was a 1--20% difference in natural frequencies between the finite element analysismore » (FEA) and test results for the 3-ply cylinders over the frequency range 88 to 577 Hz. The 2-ply configuration had overlapped ply joints and a 0.50 mm thick PTFE/copper substrate adhesively bonded to the outside. In this configuration there was approximately a 7% difference in natural frequencies between the FEA and test results. The effect of the added mass of the substrate in the test samples had a greater influence on the modal analysis than the assumption of a continuum at the overlapped ply joints. The mode shapes for each of the cylinders were comparable for all configurations tested. Damping increased by 12--38% over most of the frequency range for the 3-ply overlapped compared to the butted ply joint configuration. Damping in the 2-ply overlapped ply joint cylinder with PTFE/copper substrate showed a 48-93% (depending on frequency) increase over that of the 3-ply overlapped ply joint cylinder. An increase in damping for both 3-ply configurations and the 2-ply configuration was attributed to increased matrix shearing as a result of changes in mode shape, increased warping, and the resultant increase in internal strain.« less

  19. Three empirical essays on consumer behavior related to climate change and energy

    NASA Astrophysics Data System (ADS)

    Jacobsen, Grant Douglas

    This dissertation consists of three essays. All of the chapters address a topic in the area of household and consumer behavior related to climate change or energy. The first chapter is titled "The Al Gore Effect: An Inconvenient Truth and Voluntary Carbon Offsets". This chapter examines the relationship between climate change awareness and household behavior by testing whether Al Gore's documentary An Inconvenient Truth caused an increase in the purchase of voluntary carbon offsets. The analysis shows that in the two months following the film's release, zip codes within a 10-mile radius of a zip code where the film was shown experienced a 50 percent relative increase in the purchase of voluntary carbon offsets. The second chapter is titled "Are Building Codes Effective at Saving Energy? Evidence from Residential Billing Data in Florida". The analysis shows that Florida's energy-code change that took effect in 2002 is associated with a 4-percent decrease in electricity consumption and a 6-percent decrease in natural-gas consumption in Gainesville, FL. The estimated private payback period for the average residence is 6.4 years and the social payback period ranges between 3.5 and 5.3 years. The third chapter in this dissertation is titled "Do Environmental Offsets Increase Demand for Dirty Goods? Evidence from Residential Electricity Demand". This study evaluates the relationship between green products and existing patterns of consumer behavior by examining the relationship between household enrollment in a green electricity program and consumption of residential electricity. The results suggest there are two different types of green consumers. One type makes a small monthly donation and partially views the donation as a substitute for a previously existing pattern of green behavior, in this case, energy conservation. The other type makes a larger monthly donation and views the donation as a way to make strictly additional improvements in environmental quality.

  20. Mechanics of smooth muscle in isolated single microvessels.

    PubMed

    Gore, R W; Davis, M J

    1984-01-01

    In vivo studies on frog mesenteric arterioles (4) indicate that segmental differences in the response of microvessels to physical and chemical stimuli can be explained simply in terms of the length-tension characteristics of vascular smooth muscle at different points along the vascular tree. Studies on single, isolated arterioles in vitro were initiated to examine more closely the validity of this explanation for regional response differences. This paper reports some of the results. First-, second-, and third-order arterioles (18-60 micron i.d.) were dissected from hamster cheek pouches. The vessels were cannulated with a modified Burg microperfusion system, and their mechanical properties studied using the methods described by Duling and Gore. Vessels were activated in four stages with K+ and norepinephrine. During activation, transmural pressures were adjusted to minimize vascular smooth-muscle shortening. Active pressure-diameter curves were recorded while adjusting transmural pressure through the range 5 to 400 cm H20 in 5-25 cm steps. Vessel dimensions were measured with a videomicrometer. Passive curves were obtained after equilibration overnight in Ca2+-free medium. The vessels were then fixed and prepared for histologic sectioning, and measurements of vessel-wall composition were made. The Laplace relationship was used to construct length-tension diagrams, and the histologic data were used to normalize the dimensional data to smooth-muscle lengths. Maximum active tension of second-order arterioles (1,170 dynes/cm) was two times previous values reported by Gore et al. This was due presumably to refinements in techniques and dissection procedures. Maximum active stress averaged 3.9 X 10(+6) dynes/cm2 for second-order arterioles. This number is identical to data obtained from hog carotid strips by Dillon et al.

  1. KSC-2015-1310

    NASA Image and Video Library

    2015-02-08

    CAPE CANAVERAL, Fla. – Members of the news media listen and take photos at NASA’s Kennedy Space Center in Florida as Sen. Bill Nelson, left, and former Vice President Al Gore, right, answer questions prior to the planned liftoff of NOAA’s Deep Space Climate Observatory spacecraft, or DSCOVR. DSCOVR will launch aboard a SpaceX Falcon 9 rocket. The mission is a partnership between NOAA, NASA and the U.S. Air Force. DSCOVR will maintain the nation's real-time solar wind monitoring capabilities which are critical to the accuracy and lead time of NOAA's space weather alerts and forecasts. To learn more about DSCOVR, visit http://www.nesdis.noaa.gov/DSCOVR. Photo credit: NASA/Kim Shiflett

  2. KSC-2015-1311

    NASA Image and Video Library

    2015-02-08

    CAPE CANAVERAL, Fla. – Sen. Bill Nelson, left, answers a question as former Vice President Al Gore looks on during a visit with news media at NASA’s Kennedy Space Center in Florida prior to the planned liftoff of NOAA’s Deep Space Climate Observatory spacecraft, or DSCOVR. DSCOVR will launch aboard a SpaceX Falcon 9 rocket. The mission is a partnership between NOAA, NASA and the U.S. Air Force. DSCOVR will maintain the nation's real-time solar wind monitoring capabilities which are critical to the accuracy and lead time of NOAA's space weather alerts and forecasts. To learn more about DSCOVR, visit http://www.nesdis.noaa.gov/DSCOVR. Photo credit: NASA/Kim Shiflett

  3. Lewis Research Center: Commercialization Success Stories

    NASA Technical Reports Server (NTRS)

    Heyward, Ann O.

    1996-01-01

    The NASA Lewis Research Center, located in Cleveland, Ohio, has a portfolio of research and technology capabilities and facilities that afford opportunities for productive partnerships with industry in a broad range of industry sectors. In response to the President's agenda in the area of technology for economic growth (Clinton/Gore 1993), the National Performance Review (1993), NASA's Agenda for Change (1994), and the needs of its customers, NASA Lewis Research Center has sought and achieved significant successes in technology transfer and commercialization. This paper discusses a sampling of Lewis Research Center's successes in this area, and lessons learned that Lewis Research Center is applying in pursuit of continuous improvement and excellence in technology transfer and commercialization.

  4. KSC-04pd1199

    NASA Image and Video Library

    2004-05-18

    KENNEDY SPACE CENTER, FLA. -- A reporter from KJFF radio interviews astronaut Dom Gorie after his presentation at Trojan Intermediate School in Potosi, Mo. Students from three area schools — Potosi High School, John Evans Middle School and Trojan — are on a team taking part in NASA’s Explorer Schools program. KSC Deputy Director Dr. Woodrow Whitlow and Gore are sharing America’s new vision for space exploration with the next generation of explorers. They are talking with students about our destiny as explorers, NASA’s stepping stone approach to exploring Earth, the Moon, Mars and beyond, how space impacts our lives, and how people and machines rely on each other in space.

  5. The subjective cut: sex reassignment surgery in 1960s and 1970s science fiction.

    PubMed

    Sellberg, Karin

    2016-12-01

    This article considers the way in which ethical concerns about sex reassignment surgery and especially the research and clinical practice of the sexologist Dr John Money (1921-2006) is being negotiated in the 1960s and 1970s novels Myra Breckinridge and Myron by Gore Vidal and The Passion of New Eve by Angela Carter. Drawing on the theories of gender and embodiment developed by Money, the article reads the novels as a critical response and discursive interaction with emergent sexological concepts. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  6. The global forum on environment and development

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1990-01-01

    The first Global Conference of Spiritual and Parliamentary Leaders on Human Survival was held in Oxford, England not to discuss world issues, but to test the ability of 100 spiritual leaders and 100 parliamentarians to work together in a world which has preferred to separate church and state. This conference, held in Moscow, attracted more than 1,000 people. The main purpose was to find common solutions to environmental quality, economic development, and human survival as citizens of planet Earth. Notable addresses were heard from Javier Perez de Cuellar, Senator Albert Gore, Carl Sagan, Lester Brown, Nafis Sadik, Evguenij Velikhov, andmore » Mikhail Gorbachev who advocated an International Green Cross.« less

  7. A stress index model for ascending balloons

    NASA Technical Reports Server (NTRS)

    Smith, I. S.

    1986-01-01

    Attention is given to the development on the part of NASA of a simplified stress 'index' model to establish the relative stress magnitudes along a balloon's gore position as a function of altitude. Application of this model to several hundred balloon flights showed a good correlation between balloon failure rate and stress 'index' level. This model can be used during the balloon design process to lower the levels of stress in the balloon. By increasing the wall thickness of the balloon, adding caps, lengthening caps, or using external caps, lower stress can be accomplished. As a result, in January 1985, the NASA Balloon Program established a stress index specification to limit the design and flight stresses for NASA balloons.

  8. Vignapandeyana (Fabaceae), a new species from northern Western Ghats, India.

    PubMed

    Gaikwad, Sayajirao; Gore, Ramchandra; Randive, Sonali

    2015-01-01

    Vigna subg. Ceratotropis (Piper) Verdc. represents a homogenous and distinct group of species with highly specialized complex floral characters. It is most diverse in Asia. India, with 24 species, represents a secondary center of species diversity of the subgenus. A new species, Vignapandeyana RD Gore, SP Gaikwad & SD Randive, is described from hill slopes of the northern Western Ghats of India. It resembles Vignayadavii Gaikwad et al. and Vignadalzelliana (Kuntze) Verdc. but differs from the latter in its dimorphic shoots (some subterranean, with cleistogamous flowers) and densely hairy pods, from the former by its curved style, flattened style beak, foveolate seed coat and absence of standard protuberance and horn-like keel pocket in cleistogamous flowers.

  9. The global-village pioneers

    NASA Astrophysics Data System (ADS)

    Ginsparg, Paul

    2008-10-01

    The students whom I currently teach regard Al Gore as a Nobel-prize winner and think Google invented the Internet. They view 1998 as ancient history, whereas those of us in mid-career can remember 1988 (at least) as well as yesterday. And while each generation regards itself as somehow unique, in certain regards, some are more unique than others. In the case of my generation, there are objective reasons to believe that we have witnessed a fundamental change in the way that information is accessed, and how it is communicated to and from the general public, and among research professionals. And that is undoubtedly one of the most important paradigm shifts in recent history.

  10. Theory of cooperation in a micro-organismal snow-drift game

    NASA Astrophysics Data System (ADS)

    Wang, Zhenyu; Goldenfeld, Nigel

    2011-03-01

    We present a mean field model for the phase diagram of a community of micro-organisms, interacting through their metabolism so that they are, in effect, engaging in a cooperative social game. We show that as a function of the concentration of the nutrients glucose and histidine, the community undergoes a phase transition separating a state in which one strain is dominant to a state which is characterized by coexisting populations. Our results are in good agreement with recent experimental results, correctly predicting quantitative trends and the phase diagram. We thank Jeff Gore for sharing with us his experimental data. This work was supported in part by the National Science Foundation through grant number NSF-EF-0526747.

  11. Percutaneous biliary drainage for high obstruction.

    PubMed

    Barth, K H

    1990-11-01

    PBD is the preferred route of palliative drainage for patients with high biliary obstruction. The frequency of bifurcational obstruction in this setting requires familiarity with drainages from both the right and the left transhepatic approach. The preferred right transhepatic approach is fluoroscopically guided; on the left, ultrasonography is the guidance of choice. Large caliber drainage catheters are required, and dilatation of the necessary transhepatic tracts is extremely painful unless adequate inhalation anesthesia or, preferably, epidural anesthesia, is provided. Long-term biliary drainage requires a choice between internal-external external drainage catheters and endoprostheses that is made by considering the patient's life expectancy and his or her adjustment to a stent extending to the outside. The feasibility of corrective procedures if an internal-external drainage catheter or an endoprosthesis becomes blocked needs to be considered before definitive placement. The interventional radiologist becomes intimately involved in the follow-up care of patients and frequently has to direct appropriate patient evaluation. Familiarity with antibiotic regimens is important.

  12. Preliminary results of endovascular aneurysm sealing from the multicenter Italian Research on Nellix Endoprosthesis (IRENE) study.

    PubMed

    Gossetti, Bruno; Martinelli, Ombretta; Ferri, Michelangelo; Silingardi, Roberto; Verzini, Fabio

    2018-05-01

    Because of advances in technology and experience of the operator, endovascular aneurysm repair (EVAR) has supplanted open repair to treat abdominal aortic aneurysm (AAA). The low 30-day mortality and morbidity of EVAR make the endovascular approach particularly suitable for patients at high surgical risk. However, endoleak or endograft migration requiring secondary intervention or open surgical conversion is a limitation of EVAR. The Nellix system (Endologix, Inc, Irvine, Calif) has been designed to seal the entire AAA to overcome these limitations with EVAR. We report the results of a retrospective, multicenter study with endovascular aneurysm sealing (EVAS) aimed to assess technical success, procedure-related mortality, complications, and reinterventions. This study included patients selected for elective treatment with the Nellix device per the endovascular repair protocol at 16 Italian vascular centers. All patients were enrolled in a postoperative surveillance imaging program including duplex ultrasound investigations, computed tomography, and magnetic resonance controls following local standards of care. From 2013 to 2015, there were 335 patients (age, 75.5 ± 7.4 years; 316 men) who underwent elective EVAS. In 295 cases (88.0%), EVAS was performed under standard instructions for use of the Nellix system. Preoperative aneurysm diameter was 55.5 ± 9.4 mm (range, 46-65 mm). The inferior mesenteric artery and lumbar arteries emerging from the AAA were patent in 61.8% and 81.3% of cases, respectively. Chimney grafts were electively carried out in eight cases (2.4%). One (0.3%) intraprocedural type IB endoleak was observed and promptly corrected. Device deployment was successful in all patients, with no perioperative mortality. Early (≤30 days) complications included 1 (0.3%) type IA endoleak, 2 (0.6%) type II endoleaks (0.6%), 2 (0.6%) stent occlusions (0.6%), 3 (0.9%) distal embolizations, and 2 (0.2%) femoral artery dissections. Six (2.9%) patients underwent reinterventions. At 1-year follow-up, complications included 3 (1.1%) type II endoleaks, 4 (1.4%) type IA endoleaks, 1 (0.3%) type IB endoleak, 2 (0.7%) distal stent migrations, 5 (1.8%) distal embolizations, and 1 (0.3%) stent occlusion. Twelve patients (3.7%) underwent reinterventions, including four (1.4%) surgical conversions due to aortoduodenal fistula (1), endograft infection (1), and type IA endoleak that was unsuccessfully treated percutaneously (2). Two AAA-related deaths occurred. Freedom from aneurysm-related reintervention was 98.3% at 1-month and 94.7% at 12-month follow-up. The preliminary results of this real-world multicenter study showed that EVAS with Nellix for the management of AAAs appears feasible. This device platform is associated with acceptable procedure-related mortality and low overall complication and reintervention rates. Definitive conclusions on the value of this novel device await long-term follow-up data. Published by Elsevier Inc.

  13. [A new method for microdrainage using a porous titanium nickelide endoprosthesis in resurgery of uncompensated glaucoma].

    PubMed

    Eremenko, A I; Mogil'naia, G M; Giunter, V E; Sakhnov, S N; Stebliuk, A N

    2006-01-01

    Experimental (23 rabbits) and clinical (42 patients with operated glaucoma) studies were conducted to evaluate the effect of a titanium nickelide implant on ocular tissue in modified deep sclerectomy in order to normalize intraocular pressure. Scleral morphological studies in the area of implant placement revealed the formation of a capsule with "fissures" and vessels. Clinically, there was intraocular pressure compensation in 92.8% of the patients operated on.

  14. [Total Joint Replacement and Return to Sports].

    PubMed

    Oehler, N; Schmidt, T; Niemeier, A

    2016-12-01

    Background: An increasing number of physically active patients not only need to know if they will basically be able to engage in sports after undergoing arthroplasty. They also would like to know whether or not they will be able to resume their preoperative activity levels. This article aims to provide an overview of recent data regarding the following questions on hip, knee and shoulder arthroplasty: (1) What is the impact of physical activity on an endoprosthesis? (2) What level of sports can be achieved after an arthroplasty procedure? (3) What types of sport are recommended for patients with an endoprosthesis? Methods: PubMed-based review of the literature. Narrative review focusing on current data from the years 2010 to 2016. Results: The commonly known recommendation to exercise low-impact sports such as hiking, swimming, cycling or golf at a moderate intensity remains valid for all types of prostheses in all joints. There is broad consensus that the benefits of these sports outweigh the negative effects. Having undergone total hip or knee arthroplasty, most patients with a high preoperative activity level return to sports after 3-6 months, albeit with a clear tendency to lower intensity and a shift from high-impact to low-impact sports. Some key questions have to be answered regarding the effects of low-impact sports that are exercised with high intensity, the effects resulting from high-impact sports, effects specific to different types of sport, and possibilities provided by different prosthesis types. In this context, a lot remains to be done to investigate the limits between positive and negative effects resulting from physical activity of varying intensity. New data suggests that generally a higher physical performance level may be achieved than has been traditionally recommended. Early results of unicondylar knee prostheses are far better than those achieved with bicondylar prostheses. In contrast to expert recommendations, shoulder endoprostheses show

  15. Repair of Tricuspid Valve Leaflet With CardioCel Patch After Traumatic Tricuspid Regurgitation.

    PubMed

    Konstantinidou, Maria Kalliopi; Moat, Neil

    2017-09-01

    Posttraumatic tricuspid valve regurgitation (TR) is a rare entity and is almost always associated with blunt chest trauma. It is usually identified by transthoracic echocardiography after the manifestation of clinical symptoms of heart failure. Treatment varies from long-term medical therapy and observation to surgical correction with tricuspid valve replacement or repair. We describe the case of a 26-year-old man who was involved in a major road traffic accident and was referred for surgical repair a year later because of severe posttraumatic TR. The tricuspid valve was successfully reconstructed with a CardioCel patch, Gore-Tex neochordae, and a tricuspid ring. The patient recovered well. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  16. A Medieval Irish Treatise on Astronomy Recalled, with a Memoir of its Translator and Editor, Maura Power (1887-1916)

    NASA Astrophysics Data System (ADS)

    Bruck, M. T.; Conway-Piskorski, M.

    1998-01-01

    A 15th century treatise on astronomy in Irish, an adaptation of a Latin translation of an older Arabic text, was transcribed and published together with an English translation and commentaries under the title An Irish Astronomical Tract in 1914. This work is familiar to Celtic language scholars but is little known among astronomers. Here we briefly describe the text, and include a memoir of its editor and translator Maura Power, a young woman who combined a specialist knowledge of the Irish language with an understanding of medieval science. We also recall two other Irish scholars - the geologist Maxwell Close and the astronomer John Ellard Gore - who played their part in recognizing the value of this early Irish scientific text.

  17. Using documentaries for Earth science education

    NASA Astrophysics Data System (ADS)

    Hooper, Richard; Lilienfeld, Linda; Arrigo, Jennifer

    2011-10-01

    With the success of An Inconvenient Truth, a movie about former U.S. vice president Al Gore's campaign to educate the public on global climate change, long-form documentaries, particularly those concerning environmental issues, are enjoying a renaissance. These films can be a powerful educational tool because they create teachable moments by heightening students' interest in environmental topics. Successful documentaries engage the audience emotionally and tell a compelling story, with heroes and villains. Often films touch on some scientific concepts and may even contain graphics and animations that are useful in explaining processes. However, they generally do not provide a balanced exposition of the science and technical issues that underlie the environmental problems described. Documentaries may advocate a particular policy position.

  18. Reviews

    NASA Astrophysics Data System (ADS)

    2007-05-01

    WE RECOMMEND The Snowman's Coat and Other Science Questions A book of problem-solving for the very young An Inconvenient Truth Al Gore's climate change slide show, brought to DVD OCR Physics for GCSE A thorough but interesting high-level textbook 21st Century Science GCSE Resources A full range of resources to suit teacher and pupil WORTH A LOOK Thinking Without Objects - The Transformation of Mechanics in the Seventeenth Century This book covers a fruitful period in the history of science Paper Rollercoasters An intriguing teaching resource that uses paper and sticky tape HANDLE WITH CARE STEAM - Museum of the Great Western Railway The Swindon museum proves lacking in education resources WEB WATCH Games and simulations demonstrating moments and levers

  19. Oxygen and Fuel Jet Diffusion Flame Studies in Microgravity Motivated by Spacecraft Oxygen Storage Fire Safety

    NASA Technical Reports Server (NTRS)

    Sunderland, P. B.; Yuan, Z.-G.; Krishnan, S. S.; Abshire, J. M.; Gore, J. P.

    2003-01-01

    Owing to the absence of past work involving flames similar to the Mir fire namely oxygen-enhanced, inverse gas-jet diffusion flames in microgravity the objectives of this work are as follows: 1. Observe the effects of enhanced oxygen conditions on laminar jet diffusion flames with ethane fuel. 2. Consider both earth gravity and microgravity. 3. Examine both normal and inverse flames. 4. Compare the measured flame lengths and widths with calibrated predictions of several flame shape models. This study expands on the work of Hwang and Gore which emphasized radiative emissions from oxygen-enhanced inverse flames in earth gravity, and Sunderland et al. which emphasized the shapes of normal and inverse oxygen-enhanced gas-jet diffusion flames in microgravity.

  20. Mathematical modeling of damage in unidirectional composites

    NASA Technical Reports Server (NTRS)

    Goree, J. G.; Dharani, L. R.; Jones, W. F.

    1983-01-01

    Extending the work of Goree and Gross (1979), solutions are given for a two-dimensional region of unidirectional fibers embedded in an elastic matrix whose initial flaw may take the form of a transverse notch, a rectangular cutout, or a circular hole. Subsequent flaw-induced damage is generated by remote stresses acting parallel to the fibers. For the case of such ductile matrix composites as boron/aluminum, present results indicate that both longitudinal matrix yielding and transverse notch extension must be included in order for the model to agree with experimental results. Little difference is found for the three types of initial damage considered. In all cases, the presence of additional damage changes the nature of stress distribution through the unbroken fibers.

  1. A cellular glass substrate solar concentrator

    NASA Technical Reports Server (NTRS)

    Bedard, R.; Bell, D.

    1980-01-01

    The design of a second generation point focusing solar concentration is discussed. The design is based on reflective gores fabricated of thin glass mirror bonded continuously to a contoured substrate of cellular glass. The concentrator aperture and structural stiffness was optimized for minimum concentrator cost given the performance requirement of delivering 56 kWth to a 22 cm diameter receiver aperture with a direct normal insolation of 845 watts sq m and an operating wind of 50 kmph. The reflective panel, support structure, drives, foundation and instrumentation and control subsystem designs, optimized for minimum cost, are summarized. The use of cellular glass as a reflective panel substrate material is shown to offer significant weight and cost advantages compared to existing technology materials.

  2. Vigna pandeyana (Fabaceae), a new species from northern Western Ghats, India

    PubMed Central

    Gaikwad, Sayajirao; Randive, Sonali

    2015-01-01

    Abstract Background Vigna subg. Ceratotropis (Piper) Verdc. represents a homogenous and distinct group of species with highly specialized complex floral characters. It is most diverse in Asia. India, with 24 species, represents a secondary center of species diversity of the subgenus. New information A new species, Vigna pandeyana RD Gore, SP Gaikwad & SD Randive, is described from hill slopes of the northern Western Ghats of India. It resembles Vigna yadavii Gaikwad et al. and Vigna dalzelliana (Kuntze) Verdc. but differs from the latter in its dimorphic shoots (some subterranean, with cleistogamous flowers) and densely hairy pods, from the former by its curved style, flattened style beak, foveolate seed coat and absence of standard protuberance and horn-like keel pocket in cleistogamous flowers. PMID:25829861

  3. Game dynamic model for yeast development.

    PubMed

    Huang, Yuanyuan; Wu, Zhijun

    2012-07-01

    Game theoretic models, along with replicator equations, have been applied successfully to the study of evolution of populations of competing species, including the growth of a population, the reaching of the population to an equilibrium state, and the evolutionary stability of the state. In this paper, we analyze a game model proposed by Gore et al. (Nature 456:253-256, 2009) in their recent study on the co-development of two mixed yeast strains. We examine the mathematical properties of this model with varying experimental parameters. We simulate the growths of the yeast strains and compare them with the experimental results. We also compute and analyze the equilibrium state of the system and prove that it is asymptotically and evolutionarily stable.

  4. Outcomes of Right Ventricular Outflow Tract Reconstruction for Children with Persistent Truncus Arteriosus: A 10-Year Single-Center Experience.

    PubMed

    Luo, Kai; Zheng, Jinghao; Zhu, Zhongqun; Gao, Botao; He, Xiaomin; Xu, Zhiwei; Liu, Jinfen

    2018-03-01

    The purpose of this report is to assess the mid- and long-term outcomes of right ventricular outflow tract (RVOT) reconstruction for children with persistent truncus arteriosus. Between September 2006 and 2016, 105 patients with persistent truncus arteriosus (PTA) received surgical treatment at Shanghai Children's Medical Center. Direct right ventricle-pulmonary artery anastomosis (pulmonary artery pull-down) was performed in 51 patients; a left auricle or pericardial conduit was inserted between the RVOT and pulmonary artery as a connection in 17 patients; heterograft (bovine jugular vein or Gore-tex) conduits and homograft conduits were used in 30 and 7 cases, respectively, to connect the distal pulmonary and right ventricle outflow tract; and pulmonary valve reconstruction was performed in 38 patients using a Gore-tex monocusp. There were six in-hospital deaths and one delayed death 5 months after operation. After a mean follow-up of 55.8 ± 16.5 months (6-113 months), 19 patients underwent reoperation (3 with pulmonary patch enlargement, 14 with conduit replacement and 2 with aortic valve replacement) 10-89 months after the first operation, with 1 hospital death. The actuarial survival rates were 94.2, 93.3 and 93.3% at 1, 5 and 10 years, respectively. Freedom from reoperation was 98.0, 87.8 and 82.7% at 1, 5 and 10 years, respectively. The follow-up variables included echocardiography, chest radiography, cardiac CT and cardiac function. At the last examination, most of the patients exhibited an improvement of New York Heart Association functional class from III or IV preoperatively to I or II at follow-up. Surgical treatment for PTA has an acceptable survival rate and satisfactory outcomes. Most patients exhibited an improvement in cardiac function during follow-up. Aortic arch deformity, truncal valvular regurgitation and long cardiopulmonary bypass time were regarded as risk factors for hospital mortality. Autologous tissue has a lower reoperation

  5. The Aerogel Cerenkov detector for the SHMS magnetic spectrometer in Hall C at Jefferson Lab

    DOE PAGES

    Horn, T.; Mkrtchyan, H.; Ali, S.; ...

    2016-10-28

    Hadronic reactions producing strange quarks such as exclusive or semi-inclusive kaon production, play an important role in studies of hadron structure and the dynamics that bind the most basic elements of nuclear physics. The small-angle capability of the new Super High Momentum Spectrometer (SHMS) in Hall C, coupled with its high momentum reach - up to the anticipated 11-GeV beam energy in Hall C - and coincidence capability with the well-understood High Momentum Spectrometer, will allow for probes of such hadron structure involving strangeness down to the smallest distance scales to date. To cleanly select the kaons, a threshold aerogelmore » Cerenkov detector has been constructed for the SHMS. The detector consists of an aerogel tray followed by a diffusion box. Four trays for aerogel of nominal refractive indices of n=1.030, 1.020, 1.015 and 1.011 were constructed. The tray combination will allow for identification of kaons from 1 GeV/c up to 7.2 GeV/c, reaching 10 -2 proton and 10 -3 pion rejection, with kaon detection efficiency better than 95%. The diffusion box of the detector is equipped with 14 five-inch diameter photomultiplier tubes. Its interior walls are covered with Gore diffusive reflector, which is superior to the commonly used Millipore paper and improved the detector performance by 35%. The inner surface of the two aerogel trays with higher refractive index is covered with Millipore paper, however, those two trays with lower aerogel refractive index are again covered with Gore diffusive reflector for higher performance. The measured mean number of photoelectrons in saturation is ~12 for n=1.030, ~8 for n=1.020, ~10 for n=1.015, and ~5.5 for n=1.011. Here the design details, the results of component characterization, and initial performance tests and optimization of the detector are presented.« less

  6. The Aerogel Čerenkov detector for the SHMS magnetic spectrometer in Hall C at Jefferson Lab

    NASA Astrophysics Data System (ADS)

    Horn, T.; Mkrtchyan, H.; Ali, S.; Asaturyan, A.; Carmignotto, M.; Dittmann, A.; Dutta, D.; Ent, R.; Hlavin, N.; Illieva, Y.; Mkrtchyan, A.; Nadel-Turonski, P.; Pegg, I.; Ramos, A.; Reinhold, J.; Sapkota, I.; Tadevosyan, V.; Zhamkochyan, S.; Wood, S. A.

    2017-01-01

    Hadronic reactions producing strange quarks such as the exclusive p (e , e ‧K+) Λ and p (e , e ‧K+)Σ0 reactions, or the semi-inclusive p (e , e ‧K+) X reaction, play an important role in studies of hadron structure and the dynamics that bind the most basic elements of nuclear physics. The small-angle capability of the new Super High Momentum Spectrometer (SHMS) in Hall C, coupled with its high momentum reach - up to the anticipated 11-GeV beam energy in Hall C - and coincidence capability with the well-understood High Momentum Spectrometer (HMS), will allow for probes of such hadron structure involving strangeness down to the smallest distance scales to date. To cleanly select the kaons, a threshold aerogel Cerenkov detector has been constructed for the SHMS. The detector consists of an aerogel tray followed by a diffusion box. Four trays for aerogel of nominal refractive indices of n=1.030, 1.020, 1.015 and 1.011 were constructed. The tray combination will allow for identification of kaons from 1 GeV/c up to 7.2 GeV/c, reaching ∼10-2 proton and 10-3 pion rejection, with kaon detection efficiency better than 95%. The diffusion box of the detector is equipped with 14 five-inch diameter photomultiplier tubes. Its interior walls are covered with Gore diffusive reflector, which is superior to the commonly used Millipore paper and improved the detector performance by 35%. The inner surface of the two aerogel trays with higher refractive index is covered with Millipore paper, however, those two trays with lower aerogel refractive index are again covered with Gore diffusive reflector for higher performance. The measured mean number of photoelectrons in saturation is ∼12 for n=1.030, ∼8 for n=1.020, ∼10 for n=1.015, and ∼5.5 for n=1.011. The design details, the results of component characterization, and initial performance tests and optimization of the detector are presented.

  7. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT, BAGHOUSE FILTRATION PRODUCTS, W.L. GORE & ASSOCIATES, INC., L4427 FILTER SAMPLE

    EPA Science Inventory

    Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) Verification Center. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of the size of those particles equal to and smalle...

  8. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT - BAGHOUSE FILTRATION PRODUCTS - W.L. GORE & ASSOCIATES, INC. L4347 FILTER SAMPLE

    EPA Science Inventory

    Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) pilot of the Environmental Technology Verification (ETV) Program. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of th...

  9. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT: BAGHOUSE FILTRATION PRODUCTS, W.L. GORE & ASSOCIATES, INC. LYSB3 FILTER SAMPLE

    EPA Science Inventory

    Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) Verification Center. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of the size for particles equal to or smaller than...

  10. 75 FR 59748 - Notice of License Amendment for the Sequoyah Fuels Corporation's Facility at Gore, OK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-28

    ... The purpose of this proposed CAP is to remediate existing groundwater contamination and to facilitate... decommissioning, disposal cell construction, and surface reclamation, the CAP addresses residual contamination in... placed in hydrologically strategic positions to intercept groundwater contamination remaining onsite. The...

  11. [The use of Foley catheter in reconstructive procedures involving the middle third of the facial skeleton].

    PubMed

    Medvedev, Yu A; Petruk, P S; Shamanaeva, L S; Volkova, V A; Davidov, A R

    2016-01-01

    The aim of this study was to improve the efficiency of surgical treatment of patients with fractures involving zygomatico-orbital complex and maxillary sinus through the use of Foley catheter. 352 patients with fractures of the middle third of the facial skeleton were treated at the Departments of Oral & Maxillofacial Surgery in Novokuznetsk Institute and I.M. Sechenov First MSMU. All patients underwent open reduction and osteosynthesis using extramedullary titanium mini-plates and NiTi mini-clamps. In the cases with large bone defects additional reconstructive techniques were used such as replantation of bone fragments and endoprosthesis with NiTi implants. For the purpose of drainage and retention Foley catheter was placed in the cavity of the maxillary sinus after the surgical procedure. We obtained good and satisfactory results in the majority of clinical cases. The use of Foley catheter was found to be very effective for the post-operative drainage and hemostasis of the maxillary sinus and in cases involving the use of fixation implant in the reconstructive surgeries in the middle third of the face.

  12. Endovascular Treatment of Ruptured Abdominal Aneurysm into the Inferior Vena Cava in Patient After Stent Graft Placement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Juszkat, Robert, E-mail: radiologiamim@wp.p; Pukacki, Fryderyk; Zarzecka, Anna

    We report the case of a patient who underwent endovascular repair and then reintervention as a result of the presence of a persistent endoleak complicated by an aortocaval fistula. A 76-year-old patient with a history of endovascular treatment for abdominal aortic aneurysm 2 years earlier had a palpable abdominal mass, high-output cardiac failure, and renal failure. A computed tomographic scan and angiography revealed bending of the right iliac limb, a type I endoleak, and rupture of the aneurysm into the inferior vena cava with aortocaval fistula formation. An iliac extension was positioned in the right external iliac artery. The proceduremore » was finished successfully. Control angiography showed normal flow within the endoprosthesis, and both iliac arteries were without signs of endoleakage and aortocaval fistula. Ectatic common iliac artery may lead to a late distal attachment site endoleak. The application of a stent graft in cases of secondary aortocaval fistula after stent graft repair is a good option, particularly in emergency cases.« less

  13. MOON-test - determination of motor performance in the pediatric oncology.

    PubMed

    Götte, M; Kesting, S; Albrecht, C; Worth, A; Bös, K; Boos, J

    2013-05-01

    Pediatric cancer patients suffer from various negative consequences due to the disease, the medical therapy and the inactivity during the intensive treatment. Only few studies have systematically identified the adverse effects of cancer on motor performance in childhood. To determine the motor performance of pediatric cancer patients, a motor performance test was developed which is applicable for this specific patient group. Eight test items with reference values for healthy children were merged to the MOON-test (test for motor performance in the oncology). MOON was tested for feasibility and acceptance in 33 patients aged 4-18 years. Feasibility was confirmed for children with different types of cancer (hematological malignancies and solid tumors) and with amputation, endoprosthesis, during aplasia as well as reduced general condition. Furthermore the patients showed a broad acceptance. Based on the study findings, the use of MOON-test as a standardized motor performance diagnostic tool in clinical routine of oncological acute clinics as well as rehabilitation clinics can be recommended.· © Georg Thieme Verlag KG Stuttgart · New York.

  14. Thermal comfort of dual-chamber ski gloves

    NASA Astrophysics Data System (ADS)

    Dotti, F.; Colonna, M.; Ferri, A.

    2017-10-01

    In this work, the special design of a pair of ski gloves has been assessed in terms of thermal comfort. The glove 2in1 Gore-Tex has a dual-chamber construction, with two possible wearing configurations: one called “grip” to maximize finger flexibility and one called “warm” to maximize thermal insulation in extremely cold conditions. The dual-chamber gloves has been compared with two regular ski gloves produced by the same company. An intermittent test on a treadmill was carried out in a climatic chamber: it was made of four intense activity phases, during which the volunteer ran at 9 km/h on a 5% slope for 4 minutes, spaced out by 5-min resting phases. Finger temperature measurements were compared with the thermal sensations expressed by two volunteers during the test.

  15. 2D array transducers for real-time 3D ultrasound guidance of interventional devices

    NASA Astrophysics Data System (ADS)

    Light, Edward D.; Smith, Stephen W.

    2009-02-01

    We describe catheter ring arrays for real-time 3D ultrasound guidance of devices such as vascular grafts, heart valves and vena cava filters. We have constructed several prototypes operating at 5 MHz and consisting of 54 elements using the W.L. Gore & Associates, Inc. micro-miniature ribbon cables. We have recently constructed a new transducer using a braided wiring technology from Precision Interconnect. This transducer consists of 54 elements at 4.8 MHz with pitch of 0.20 mm and typical -6 dB bandwidth of 22%. In all cases, the transducer and wiring assembly were integrated with an 11 French catheter of a Cook Medical deployment device for vena cava filters. Preliminary in vivo and in vitro testing is ongoing including simultaneous 3D ultrasound and x-ray fluoroscopy.

  16. [Geriatric Proximal Femoral Fracture and Urinary Tract Infection - Considerations for Perioperative Infection Prophylaxis].

    PubMed

    Probst, A; Reimers, N; Hecht, A; Langenhan, R

    2016-10-01

    Background: Perioperative infection prophylaxis with cephalosporins is standard in surgical treatment of proximal femoral fractures (PFF). Geriatric patients (pat.) are at risk of chronic infections and the bacteria from these can lead to unknown hygienic problems in an early operation. We therefore characterised the colonisation of the urinary tract in pat. (≥ 65 years) with PFF and observed bacterial development in deep wound infections over a period of 10 years. The aim was to discover gaps in perioperative infection prophylaxis. Patients and Methods: Between September 2013 and November 2015, colonisation of the urinary tract and microbial resistance were investigated on admission of all pat. (≥ 65 years) with the diagnosis of PFF (n = 351; f/m 263/88; median age [∅] 83.57 [65-100] years). Between 2005 and 2014, 2161 pat. with a PFF were operated in our clinic (f/m 1623/538; ∅ 82.35 [65-101] years). 991 pat. (∅ 81.84 [65-101] years) with femoral neck fracture [FNF] were treated with endoprosthesis/osteosynthesis, 1170 pat. (∅ 82,78 [65-101] years) with per-/subtrochanteric fracture [PTF] were treated with osteosynthesis. In a retrospective data analysis, deep wound infections, microbiological composition and changes in microbial resistances over time were identified. Results: Bacteriuria (BU) was detected in the urine sediment of 35.61 % (n = 125) of our pat. In 47.2 % of these pat., BU was accompanied by laboratory signs of manifest urinary tract infection. In 10.4 % of these pat., colonisation of the urinary tract with multi-resistant pathogens was detected; 26.4 % were resistant to cefuroxime. The rate of deep infections in pat. with endoprosthesis/osteosynthesis in FNF was 2.8 % (n = 28; f/m 19/9; ∅ 81.35 [67-92] years), with osteosynthesis in PTF 1,1 % (n = 14; f/m 10/4; ∅ 81.0 [70-91] years). A comparison of the periods 2005-2009 and 2010-2014 showed a shift in the spectrum of pathogens from cephalosporin

  17. Treatment of osteosarcoma around the knee in skeletally immature patients

    PubMed Central

    Yao, Weitao; Cai, Qiqing; Wang, Jiaqiang; Gao, Songtao

    2017-01-01

    Limb sparing surgery in growing young patients with malignant tumors is difficult as invasion of the physis by the tumor or surgical resection through the metaphysis may cause significant limb discrepancy following surgery. At present, hinged tumor prosthesis or biological reconstructions are the main methods following tumor resection in these patients. The aim of the present study was to assess different procedures for the treatment of osteosarcoma around knee joints in immature patients. A retrospective study of 56 patients (<15 years old, open physis) who had been treated for osteosarcoma around the knee joint between January 2007 and December 2015 was performed. Clinical data collected included patient demographics (age at diagnosis, sex and date of diagnosis), tumor characteristics [location, Enneking stage and subtype on magnetic resonance imaging (MRI)], treatment (response to neoadjuvant chemotherapy and type of primary surgery) and clinical outcomes (limb function, discrepancy and overall survival). The median age at the time of diagnosis was 12.14 years (range, 3–15 years). There were 32 male patients (57.1%). A total of 41 (82%) tumors were located at the distal femur, and 15 (18%) at the proximal tibia. A total of 49 (87.5%) patients were diagnosed with stage IIB tumors, and 7 (12.5%) had stage III, according to the Enneking stage classification. Different surgical methods, including amputation, rotation-plasty, endoprosthesis and biological instructions (e.g., allograft) were performed according to MRI type classification. During follow-up, 21 patients (37.5%) succumbed to disease. The Musculoskeletal Tumor Society score ranged from excellent to fair functional result. Recurrence (2 cases, 16.67%) and infection (2, cases, 16.67%) were the main complications following endoprosthesis replacement, while delayed union (12 cases, 57.14%) and fracture (3 cases, 14.29%) were the main causes for biological reconstructions. Limb-length discrepancy ranged from

  18. Management of Gastropleural Fistula after Revisional Bariatric Surgery: A Hybrid Laparoendoscopic Approach.

    PubMed

    Ghanem, Omar M; Abu Dayyeh, Barham K; Kellogg, Todd A

    2017-10-01

    Gastropleural fistula (GPF) is a serious complication after bariatric surgery. Multiple treatment modalities including pharmacologic, endoscopic, and revisional surgery have been proposed. We present a case of a GPF managed successfully with a laparoendoscopic approach utilizing a fistula plug. A 43-year-old male patient presented with a GPF after a revisional bariatric surgery. A laparoendoscopic approach including lysis of adhesions, identification of the fistula, plugging the fistula with a BioGore A® fistula plug, placement an enteric stent, placement of a feeding tube, and surgical drainage was performed. The multimedia video illustrates the technique used. Postoperatively, upper gastrointestinal (UGI) imaging showed no evidence of leak. The enteric stent was removed after 2 months after verifying complete healing of the fistula. A laparoendoscopic approach to GPF repair with the use of fistula plug is effective, safe, and feasible.

  19. Development status of the PDC-1 Parabolic Dish Concentrator

    NASA Technical Reports Server (NTRS)

    Thostesen, T.; Soczak, I. F.; Pons, R. L.

    1982-01-01

    The status of development of the 12 m diameter parabolic dish concentrator which is planned for use with the Small Community Solar Thermal Power System. The PDC-1 unit features the use of plastic reflector film bonded to structural plastic gores supported by front-bracing steel ribs. An elevation-over-azimuth mount arrangement is employed, with a conventional wheel-and-track arrangement; outboard trunnions permit the dish to be stored in the face down position, with the added advantage of easy access to the power conversion assembly. The control system is comprised of a central computer (LSI 1123), a manual control panel, a concentrator control unit, two motor controllers, a Sun sensor, and two angular position resolvers. The system is designed for the simultaneous control of several concentrators. The optical testing of reflective panels is described.

  20. OTA director to be Clinton's science advisor

    NASA Astrophysics Data System (ADS)

    Leath, Audrey

    President Clinton has nominated John H. “Jack” Gibbons to be Assistant to the President for Science and Technology, and director of the White House Office of Science and Technology Policy (OSTP). For over a decade, Gibbons has served as director of the Office of Technology Assessment (OTA), a bipartisan research arm of Congress.In nominating Gibbons, Clinton said, “I am delighted to appoint a brilliant scientist and gifted administrator… It is profoundly important that the president have a science advisor who understands science, who understands technology, who understands the practical application of these disciplines to the myriad of problems we face today. And I can tell you that from [Vice-president] Al Gore on down to every other member of Congress I have discussed John Gibbons with, I have hardly ever received more glowing and more consistent recommendations for anyone.”

  1. Late Complication after Superficial Femoral Artery (SFA) Aneurysm: Stent-graft Expulsion Outside the Skin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pecoraro, Felice, E-mail: felicepecoraro@libero.it; Sabatino, Ermanno R.; Dinoto, Ettore

    A 78-year-old man presented with a 7-cm aneurysm in the left superficial femoral artery, which was considered unfit and anatomically unsuitable for conventional open surgery for multiple comorbidities. The patient was treated with stent-graft [Viabhan stent-graft (WL Gore and Associates, Flagstaff, AZ)]. Two years from stent-graft implantation, the patient presented a purulent secretion and a spontaneous external expulsion through a fistulous channel. No claudication symptoms or hemorrhagic signs were present. The pus and device cultures were positive for Staphylococcus aureus sensitive to piperacillin/tazobactam. Patient management consisted of fistula drainage, systemic antibiotic therapy, and daily wound dressing. At 1-month follow-up, themore » wound was closed. To our knowledge, this is the first case of this type of stent-graft complication presenting with external expulsion.« less

  2. Attitude importance as a moderator of the relationship between implicit and explicit attitude measures.

    PubMed

    Karpinski, Andrew; Steinman, Ross B; Hilton, James L

    2005-07-01

    The authors examined attitude importance as a moderator of the relationship between the Implicit Association Test (IAT) and explicit attitude measures. In Study 1 (N = 194), as ratings of attitude importance regarding the 2000 presidential election increased, the strength of the relationship between a Bush-Gore IAT and explicit attitude measures also increased. Study 2 provided a conceptual replication of these results using attitudes toward Coke and Pepsi (N = 112). In addition, across both studies, explicit attitude measures were better predictors of deliberative behaviors than IAT scores. In Study 3 (N = 77), the authors examined the role of elaboration as a mechanism by which attitude importance may moderate IAT-explicit attitude correlations. As predicted, increased elaboration resulted in stronger IAT-explicit attitude correlations. Other possible mechanisms by which attitude importance may moderate the IAT-explicit attitude relationship also are discussed.

  3. Port closure techniques.

    PubMed

    Shaher, Z

    2007-08-01

    Laparoscopic trocars do create wounds. This article aims to review and list different techniques used for closure of the fascia incision at trocar sites. A literature search was performed for articles dealing with closure techniques. The author searched this subject in English on Medline by combining the words "trocar" and "hernia," as well as "Deschamps" and "Reverdin." All articles reporting techniques with their references were reviewed. The articles described many techniques in addition to classical closure using curved needles, including Grice needle, Maciol needles, Endoclose device, Carter-Thomason device, Tahoe ligature device, Endo-Judge device, eXit puncture closure device, Lowsley retractor, spinal cord needles, dual hemostat, suture carrier, Riverdin and Deschamps needles, and Gore-Tex closure device. Three main groups of techniques were found with favor of extracorporeal manipulations under direct visualization. Old methods are sufficient and cost-effective.

  4. 2018 Giant Dust Storm on Mars

    NASA Image and Video Library

    2018-06-13

    This set of images from NASA's Mars Reconnaissance Orbiter (MRO) shows a fierce, giant dust storm is kicking up on Mars, with rovers on the surface indicated as icons. The spread of the storm can be seen in the salmon-colored overlay. These images from MRO's Mars Color Imager start from May 31, when the dust event was first detected, and go through June 11, 2018. MRO creates global maps of Mars but roll maneuvers for targeted observations produce gaps in the coverage, which appear as black gores in the maps. On some days there are data drops where partial or full orbits of coverage are missing. Green and purple observed in the south polar region indicate saturated pixels. Latitude is indicated along the vertical axis. Longitude is indicated along the horizontal axis. https://photojournal.jpl.nasa.gov/catalog/PIA22519

  5. Unruptured Aneurysm of Sinus of Valsalva Coexisting with the Large Ventricular Septal Defect and Severe Aortic Regurgitation in a Young Man

    PubMed Central

    Nezafati, Pouya; Nezafati, Mohammad Hassan; Hoseinikhah, Hamid

    2015-01-01

    Introduction. Unruptured sinus of valsalva aneurysm (SVA) is a rare congenital anomaly, particularly, when it coexists with a ventricular septal defect (VSD) and aortic regurgitation due to the prolapse of the elongated aortic cusp into the VSD. In this report, we present the case of a 19-year-old young man with VSD challenging in spite of dyspnea and lower limb edema. Presentation of Case. Its diagnosis was made on the basis of transthoracic echocardiography results. Surgical management consisted of replacing the SVA with mechanical valve prosthesis. A Gore-Tex patch repaired the VSD. Discussion. In the follow-up periods, clinical and echocardiographic tests showed that the patient was in excellent status. Conclusion. SVA requires a surgical procedure due to its high risk of mortality in unoperated patients and a good safety of surgery. PMID:26236342

  6. KSC-99pp0836

    NASA Image and Video Library

    1999-07-16

    Morley Winograd (right), director of the National Partnership for Reinventing Government, presents the Hammer Award to Ed Gormel (left) and Chris Fairey (center) at a special presentation in the IMAX 2 Theater in the Kennedy Space Center Visitor Complex. The Hammer Award is Vice President Al Gore's special recognition of teams of federal employees who have made significant contributions in support of the principles of the National Partnership for Reinventing Government. This Hammer Award acknowledges the accomplishments of a joint NASA and Air Force team that established the Joint Base Operations and Support Contract (J-BOSC) Source Evaluation Board (SEB). Gormel and Fairey are co-chairs of the SEB. The team developed and implemented the acquisition strategy for establishing a single set of base operations and support service requirements for KSC, Cape Canaveral Air Station and Patrick Air Force Base

  7. KSC-99pp0835

    NASA Image and Video Library

    1999-07-16

    Ed Gormel (left) and Chris Fairey (center) accept the Hammer Award at a special presentation in the IMAX 2 Theater in the Kennedy Space Center Visitor Complex. Presenting the award is Morley Winograd (right), director of the National Partnership for Reinventing Government. The Hammer Award is Vice President Al Gore's special recognition of teams of federal employees who have made significant contributions in support of the principles of the National Partnership for Reinventing Government. This Hammer Award acknowledges the accomplishments of a joint NASA and Air Force team that established the Joint Base Operations and Support Contract (J-BOSC) Source Evaluation Board (SEB). Gormel and Fairey are co-chairs of the SEB. The team developed and implemented the acquisition strategy for establishing a single set of base operations and support service requirements for KSC, Cape Canaveral Air Station and Patrick Air Force Base

  8. Fixing Climate: What Past Climate Changes Reveal About the Current Threat-And How to Counter It

    NASA Astrophysics Data System (ADS)

    McKinley, Galen A.

    2008-10-01

    The Earth's climate is changing due to human activities. Recent polls suggest that the U.S. public generally recognizes this fact, and the efforts that led the Intergovernmental Panel on Climate Change (IPCC) and former U.S. vice president Al Gore to win the 2007 Nobel Peace Prize have played no small role in bringing most of the public to realize what scientists have been discussing for years. Yet aside from distorted Hollywood movie accounts such as The Day After Tomorrow, the public knows little about the potential for abrupt change in the climate system. With support from climate science philanthropist Gary Comer, climate scientist Wally Broecker has teamed with science writer Robert Kunzig in this book to bring abrupt climate change into public view. They do this elegantly and convincingly, making the first 12 chapters quite enjoyable.

  9. Modelling of the mechanical behavior of a polyurethane finger interphalangeal joint endoprosthesis after surface modification by ion implantation

    NASA Astrophysics Data System (ADS)

    Beliaev, A.; Svistkov, A.; Iziumov, R.; Osorgina, I.; Kondyurin, A.; Bilek, M.; McKenzie, D.

    2016-04-01

    Production of biocompatible implants made of polyurethane treated with plasma is very perspective. During plasma treatment the surface of polyurethane acquires unique physic-chemical properties. However such treatment may change the mechanical properties of polyurethane which may adversely affect the deformation behaviour of the real implant. Therefore careful study of the mechanical properties of the plasma-modified polyurethane is needed. In this paper, experimental observations of the elastic characteristics of plasma treated polyurethane and modelling of the deformation behaviour of polyurethane bio-implants are reported.

  10. Demonstration of the AGI Universal Samplers (F.K.A. the GORE Modules) for Passive Sampling of Groundwater

    DTIC Science & Technology

    2014-03-27

    Coefficient from Water into the Sorbent KOW Octanol-Water Partition Coefficient LF Low Flow LNAPL Light Non-aqueous Phase Liquid LTM Long-Term...Once in the vapor phase, the molecule can then diffuse through the mem- ERDC/CRREL TR-14-4 5 brane while liquid water is prevented from passing...remediation at this site was conducted in two phases. Phase I consisted of vertical contamina- tion profiling followed by the in situ injection of an

  11. Dedifferentiated chondrosarcoma with telangiectatic osteosarcoma-like features.

    PubMed

    Okada, K; Hasegawa, T; Tateishi, U; Endo, M; Itoi, E

    2006-11-01

    A 35-year-old Japanese man was admitted to the National Cancer Center, Tokyo, Japan, in December 2000, with a 2-month history of pain around the left thigh. Radiographs showed a poorly demarcated osteolytic lesion with focal mineralisation and endosteal scalloping in the left proximal femur. Biopsy showed a proliferation of highly anaplastic cells without any cartilaginous component. A wide excision of the left proximal femur with a replacement by endoprosthesis was carried out in February 2001 after treatment with methotrexate and 20 Gy radiation therapy. Pathological examination of the surgical specimen showed a focus of low-grade chondrosarcoma and the coexistence of telangiectatic osteosarcoma-like features. The patient was diagnosed with dedifferentiated chondrosarcoma with telangiectatic osteosarcoma-like features. Lung metastasis appeared in July 2001 despite an adjuvant chemotherapy including methotrexate, cis-platinum and doxorubicin. The latest follow-up study in June 2004 showed multiple lung metastases. Establishing a definitive diagnosis of dedifferentiated chondrosarcoma may be difficult with limited small biopsy specimens. Dedifferentiated chondrosarcoma should be included in the differential diagnosis of osteolytic tumours with focal calcification and endosteal scalloping even if an extraosseous tumour component is not identified.

  12. Dedifferentiated chondrosarcoma with telangiectatic osteosarcoma‐like features

    PubMed Central

    Okada, K; Hasegawa, T; Tateishi, U; Endo, M; Itoi, E

    2006-01-01

    A 35‐year‐old Japanese man was admitted to the National Cancer Center, Tokyo, Japan, in December 2000, with a 2‐month history of pain around the left thigh. Radiographs showed a poorly demarcated osteolytic lesion with focal mineralisation and endosteal scalloping in the left proximal femur. Biopsy showed a proliferation of highly anaplastic cells without any cartilaginous component. A wide excision of the left proximal femur with a replacement by endoprosthesis was carried out in February 2001 after treatment with methotrexate and 20 Gy radiation therapy. Pathological examination of the surgical specimen showed a focus of low‐grade chondrosarcoma and the coexistence of telangiectatic osteosarcoma‐like features. The patient was diagnosed with dedifferentiated chondrosarcoma with telangiectatic osteosarcoma‐like features. Lung metastasis appeared in July 2001 despite an adjuvant chemotherapy including methotrexate, cis‐platinum and doxorubicin. The latest follow‐up study in June 2004 showed multiple lung metastases. Establishing a definitive diagnosis of dedifferentiated chondrosarcoma may be difficult with limited small biopsy specimens. Dedifferentiated chondrosarcoma should be included in the differential diagnosis of osteolytic tumours with focal calcification and endosteal scalloping even if an extraosseous tumour component is not identified. PMID:17071806

  13. New TiAg composite coating for bone prosthesis engineering shows promising microvascular compatibility in the murine dorsal skinfold chamber model.

    PubMed

    Behrendt, Ann-Kathrin; Beythien, Maximilian; Huber, Jakob; Zufraß, Thorsten; Butschkau, Antje; Mittlmeier, Thomas; Vollmar, Brigitte

    2015-01-01

    The incorporation of antimicrobial substances like silver into implant surface coatings is one promising concept against primary infections of endoprosthesis, especially for immunocompromised patients as well as against reinfection after revision operations. However, besides good antimicrobial and mechanical properties it is equally important that the implant material does not disturb the local microvascular perfusion of muscle tissue to enable microbial host defense and tissue repair processes. In this study the biocompatibility of a newly developed TiAg-composite coating applied on conventional titanium via physical vapor deposition was analysed. To evaluate the local microvascular and inflammatory response of striated muscle tissue upon implantation of TiAg-coated plates the murine dorsal skinfold chamber model was used. We repetitively examined local capillary and venular perfusion, endothelial integrity as well as leucocyte activation by intravital fluorescence microscopy at 1 h, 24 h as well as 3 and 7 days after implantation. TiAg-implants were well tolerated by the vascular system as indicated by intact functional capillary density and endothelial integrity compared to pure titanium plates and controls without a metal implant. Furthermore, quantification of rolling and adherent leucocytes did not reveal signs of inflammation upon TiAg-implantation.

  14. Custom-made hinged spacers in revision knee surgery for patients with infection, bone loss and instability.

    PubMed

    Macmull, S; Bartlett, W; Miles, J; Blunn, G W; Pollock, R C; Carrington, R W J; Skinner, J A; Cannon, S R; Briggs, T W R

    2010-12-01

    Polymethyl methacrylate spacers are commonly used during staged revision knee arthroplasty for infection. In cases with extensive bone loss and ligament instability, such spacers may not preserve limb length, joint stability and motion. We report a retrospective case series of 19 consecutive patients using a custom-made cobalt chrome hinged spacer with antibiotic-loaded cement. The "SMILES spacer" was used at first-stage revision knee arthroplasty for chronic infection associated with a significant bone loss due to failed revision total knee replacement in 11 patients (58%), tumour endoprosthesis in four patients (21%), primary knee replacement in two patients (11%) and infected metalwork following fracture or osteotomy in a further two patients (11%). Mean follow-up was 38 months (range 24-70). In 12 (63%) patients, infection was eradicated, three patients (16%) had persistent infection and four (21%) developed further infection after initially successful second-stage surgery. Above knee amputation for persistent infection was performed in two patients. In this particularly difficult to treat population, the SMILES spacer two-stage technique has demonstrated encouraging results and presents an attractive alternative to arthrodesis or amputation. Copyright © 2009 Elsevier B.V. All rights reserved.

  15. SLI Complex Curvature Friction Stir Weld Risk Reduction Program

    NASA Technical Reports Server (NTRS)

    Hartley, Paula J.; Schneider, Jules; Jones, Chip; Lawless, Kirby; Russell, Carolyn

    2003-01-01

    The Space Launch Initiative Program (SLI) in conjunction with the National Center for Advanced Manufacturing (NCAM) will demonstrate the ability to produce large-scale complex curvature hardware using the self-reacting friction stir welding process. This multi-phased risk reduction program includes friction stir welding process development and manufacture of a 22-ft diameter quarter dome using a conventional tooling approach; it culminates in a 27.5-ft diameter quarter dome demonstration performed on a 5-axis Universal Weld System. The design, fabrication, and installation of the Universal Weld System is made possible through a collaboration between the State of Louisiana, NASA, and the University of New Orleans. The Universal Weld System, manufactured by MTS Systems Corporation, will be installed at the Michoud Assembly Facility in New Orleans, Louisiana, and will be capable of manufacturing domes up to 30 ft in diameter. All welding will be accomplished using the Adaptable Adjustable Pin Tool (AdAPT) weld head and controller manufactured by MTS. Weld parameters will be developed for an aluminum alloy in gauges ranging from 0.320 to 0.400 in. thick. Weld quality will be verified through radiography, mechanical property testing at ambient and LN2 temperatures, and metallurgical analysis. The AdAPT weld head will then be mounted on a 22-ft diameter dome tool, which will be modified to include a welding track and drive system for moving the AdAPT weld head along the weld joint. This tool will then be used to manufacture a 22-ft diameter dome of an aluminum alloy, with 0.320-in. constant thickness joints, consisting of three individual gore panels. Finally, the 27.5-ft diameter quarter dome will be welded on the Universal Weld System. The quarter dome will consist of three individual gore panels with weld lands tapering from 0.320 to 0.360 in. in thickness. With the demonstration of these welds, the ability to manufacture large diameter domes using the friction stir

  16. Shortwave Hyperspectral Observations During MAGIC Final Campaign Summary

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McBride, P. J.; Marshak, A.; Yang, W.

    The Marine ARM GPCI1 Investigation of Clouds (MAGIC) field campaign was initiated to improve our understanding of low-level marine clouds that have a significant influence on the Earth’s climate. The campaign was conducted using an ARM mobile facility deployed on a commercial ship traveling between Honolulu, Hawaii, and Los Angeles, California, from October 2012 to September 2013. The solar spectral flux radiometer (SSFR) was deployed on July 6, 2013, through the end of the campaign. The SSFR was calibrated and installed by Warren Gore of NASA Ames Research Center, and the data is and will be analyzed by Drs. Alexandermore » Marshak and Weidong Yang of NASA Goddard Space Flight Center, Dr. Samuel LeBlanc of NASA Ames Research Center, Dr. Sebastian Schmidt of the University of Colorado-Boulder, and Dr. Patrick McBride of Atmospheric & Space Technology Research Associates in Boulder, Colorado.« less

  17. KSC-99pp0832

    NASA Image and Video Library

    1999-07-16

    At a special presentation in the IMAX 2 Theater in the Kennedy Space Center Visitor Complex, KSC and 45th Space Wing employees share the honors as recipients of the Hammer Award. The Hammer Award is Vice President Al Gore's special recognition of teams of federal employees who have made significant contributions in support of the principles of the National Partnership for Reinventing Government. Morley Winograd, director of the National Partnership for Reinventing Government, presented the award to Ed Gormel and Chris Fairey, co-chairs of the Joint Base Operations and Support Contract (J-BOSC) Source Evaluation Board (SEB. This Hammer Award acknowledges the accomplishments of a joint NASA and Air Force team that established the J-BOSC SEB. The team developed and implemented the acquisition strategy for establishing a single set of base operations and support service requirements for KSC, Cape Canaveral Air Station and Patrick Air Force Base

  18. The Hammer Award is presented to KSC and 45th Space Wing.

    NASA Technical Reports Server (NTRS)

    1999-01-01

    At a special presentation in the IMAX 2 Theater in the Kennedy Space Center Visitor Complex, KSC and 45th Space Wing employees share the honors as recipients of the Hammer Award. The Hammer Award is Vice President Al Gore's special recognition of teams of federal employees who have made significant contributions in support of the principles of the National Partnership for Reinventing Government. Morley Winograd, director of the National Partnership for Reinventing Government, presented the award to Ed Gormel and Chris Fairey, co-chairs of the Joint Base Operations and Support Contract (J-BOSC) Source Evaluation Board (SEB. This Hammer Award acknowledges the accomplishments of a joint NASA and Air Force team that established the J-BOSC SEB. The team developed and implemented the acquisition strategy for establishing a single set of base operations and support service requirements for KSC, Cape Canaveral Air Station and Patrick Air Force Base.

  19. Health programs at risk in wake of '84 election.

    PubMed

    Iglehart, J K

    1985-01-01

    President Ronald Reagan's reelection suggests that government will continue to promote policies that favor marketplace allocation of medical care resources and that it will continue to cut social welfare programs, particularly health programs for the elderly and the poor. Unlike previous administrations, which focused on controlling private and public health care costs, President Reagan has targeted Medicare and Medicaid expenditures--a policy which has caused substantial cost shifting to underwrite hospitals' uncompensated and undercompensated care. Physician payment policies likely will receive the greatest attention in spending reduction efforts. Congress, as it showed in the president's first term, can cut spending sharply. Its task, however, has been complicated by the president's campaign declaration that defense spending and Social Security benefits were off-limits. Expected to lead health care debate on Capitol Hill are Sens. Albert Gore, Jr., D-TN, and Phil Gramm, R-TX, and Rep. James Jones, D-OK.

  20. Influence of thermofixation on artificial ACL ligament dimensional and mechanical properties

    NASA Astrophysics Data System (ADS)

    Ben Abdessalem, S.; Jedda, H.; Skhiri, S.; Karray, S.; Dahmen, J.; Boughamoura, H.

    2005-11-01

    The anterior cruciate ligament (ACL) is the major articular ligamentous structure of the knee, it functions as a joint stabilizer. When ruptured, the natural ACL ligament can be replaced by a textile synthetic ligament such as a braid, knitted cord, or woven cord. Theses structures are composed of biocompatible materials such as polyester or Gore-Tex filaments. The success of an ACL replacement is widely linked to its mechanical and dimensional properties such as tensile strength, dimensional stability and resistance to abrasion. We introduced an additional treatment in the manufacturing of textile ACL ligaments based on the thermofixation of the textile structure by using textile industry stabilization techniques. Boiling water, saturated vapor and dry heat have been tested to stabilize a braided ligament made of Dacron polyester. The application of these three techniques led to shrinkage and an increase of breaking strength of the textile structure.

  1. KSC-99pp0831

    NASA Image and Video Library

    1999-07-16

    Ed Gormel (left) and Chris Fairey (center) display the Hammer Award they received at a special presentation in the IMAX 2 Theater in the Kennedy Space Center Visitor Complex. The Hammer Award is Vice President Al Gore's special recognition of teams of federal employees who have made significant contributions in support of the principles of the National Partnership for Reinventing Government. At the podium is Morley Winograd director of the National Partnership for Reinventing Government, who presented the award. This Hammer Award acknowledges the accomplishments of a joint NASA and Air Force team that established the Joint Base Operations and Support Contract (J-BOSC) Source Evaluation Board (SEB). Fairey and Gormel are co-chairs of the SEB. The team developed and implemented the acquisition strategy for establishing a single set of base operations and support service requirements for KSC, Cape Canaveral Air Station and Patrick Air Force Base

  2. Global temperatures and the global warming ``debate''

    NASA Astrophysics Data System (ADS)

    Aubrecht, Gordon

    2009-04-01

    Many ordinary citizens listen to pronouncements on talk radio casting doubt on anthropogenic global warming. Some op-ed columnists likewise cast doubts, and are read by credulous citizens. For example, on 8 March 2009, the Boston Globe published a column by Jeff Jacoby, ``Where's global warming?'' According to Jacoby, ``But it isn't such hints of a planetary warming trend that have been piling up in profusion lately. Just the opposite.'' He goes on to write, ``the science of climate change is not nearly as important as the religion of climate change,'' and blamed Al Gore for getting his mistaken views accepted. George Will at the Washington Post also expressed denial. As a result, 44% of U.S. voters, according to the January 19 2009 Rasmussen Report, blame long-term planetary trends for global warming, not human beings. Is there global cooling, as skeptics claim? We examine the temperature record.

  3. [Are There any Differences in Quality or Complication Rate in Total Knee Arthroplasty after Establishing a Centre for Endoprosthesis?

    PubMed

    Düzgünoglu, Muzaffer; Hönle, Wolfgang; Scheller, Alexander; Schuh, Alexander

    2018-05-18

    The aim of the study is to show whether there are any changes in quality or incidence of complications in total knee arthroplasty (TKA) after establishing a centre for endoprothesis (EPZ). We conducted a retrospective study comparing 100 TKAs one year before establishing an EPZ (Group I) with 100 TKAs one year after establishing an EPZ (group II). Data were collected by analysing our electronic documentation system, and the report of the rehabilitation hospital. The following parameters were documented which are necessary to establish an EPZ: existence of X-rays before and after operation. Existence of full length weight bearing X-ray before operation or using a navigation device. Existence of preoperative planning, duration of TKA below 100 minutes. The following complications were documented: Periprosthetic infections, occurrence of periprosthetic fissures/fractures, thrombembolism, neurologic complications, patients' satisfaction rate with the hospital stay and mortality rate. Additionally femorotibial angle, femoral angle, tibial angle and tibial slope were measured. Statistical analysis was performed with SPSS 22.0. using the Kolmogorov-Smirnov test, the Qui-Square test and the Mann-Whitney U test. There were no statistical differences in local or systemic complications. The mean duration of operation was 82.9 min in group I (min.: 55, max.: 141) und 81.5 min in group II (min.: 57, max.: 129; p > 0.05). In group I, there were 20/100 cases (20%) with operation time longer than 100 minutes, in group II 13/100 cases (13%; p < 0.001). Analysis of anatomical femorotibial angle, femur angle, tibial angle and tibial slope showed no significant differences. The rate of documented survey of patients' satisfaction rate improved from 62% in group I to 98% in group II (p < 0.001). By establishing an EPZ, we achieved a significant improvement in the parameters operation time > 100 minutes and documented survey of patients' satisfaction rate, but not in complication rate. Georg Thieme Verlag KG Stuttgart · New York.

  4. Environmental Technology Verification: Baghouse filtration products--W.L. Gore & Associates L3650 filtration media (tested November--December 2009)

    EPA Science Inventory

    The U.S. Environmental Protection Agency (EPA) has created the Environmental Technology Verification (ETV) Program to facilitate the deployment of innovative or improved environmental technologies through performance verification and dissemination of information. ETV seeks to ach...

  5. Clinical experience with fibrin glue in cardiac surgery.

    PubMed

    Köveker, G; de Vivie, E R; Hellberg, K D

    1981-10-01

    Cardiac surgery is often associated with hemostatic abnormalities leading to severe bleeding. Special problems are to be expected, if prosthetic material has to be implanted. Preclotting of Dacron prostheses with blood is well established but failures are sometimes encountered. Several years ago a new hemostatic sealing system (fibrin glue) was introduced into therapy. Since 1978 fibrin glue has been applied in 176 patients. The indications were: 1. sealing of woven Dacron prostheses, 2. bleeding from suture-holes (Gore-Tex), 3. diffuse myocardial bleeding and 4. prevention of kinking of coronary artery grafts. In 32 patients with an aortoventriculoplasty operation using Dacron the "blood preclotting" and "fibrin sealing" methods were compared. In the fibrin glue group there was a significant reduction in postoperative blood loss as well as a shortening of the operation time (period of protamin administration to skin closure). No fibrinolytic dissolution of the fibrin layer on the prostheses was observed.

  6. KSC-99pp0833

    NASA Image and Video Library

    1999-07-16

    Commander of the Air Force Space Command, General Richard B. Myers (left) joins Ed Gormel (center) and Commander of the 45th Space Wing Brig. Gen. F. Randall Starbuck (right) after the presentation of the Hammer Award. The Hammer Award is Vice President Al Gore's special recognition of teams of federal employees who have made significant contributions in support of the principles of the National Partnership for Reinventing Government. Morley Winograd, director of the National Partnership for Reinventing Government, presented the award to the Joint Base Operations and Support Contract (J-BOSC) Source Evaluation Board (SEB). Gormel is a co-chair of the SEB. This Hammer Award acknowledges the accomplishments of a joint NASA and Air Force team that established the J-BOSC SEB. The team developed and implemented the acquisition strategy for establishing a single set of base operations and support service requirements for KSC, Cape Canaveral Air Station and Patrick Air Force Base

  7. Physiologic Simulation of the Fontan Surgery with Variable Wall Properties and Respiration

    NASA Astrophysics Data System (ADS)

    Long, Christopher; Bazilevs, Yuri; Feinstein, Jeffrey; Marsden, Alison

    2010-11-01

    Children born with single ventricle heart defects typically undergo a surgical procedure known as a total cavopulmonary connection (TCPC). The goal of this work is to perform hemodynamic simulations accounting for motion of the arterial walls in the TCPC. We perform fluid structure interactions (FSI) simulations using an Arbitrary Lagrangian Eulerian (ALE) finite element framework into a patient-specific model of the TCPC. The patient's post-op anatomy is reconstructed from MRI data. Respiration rate, heart rate, and venous pressures are obtained from catheterization data, and flowrates are obtained from phase contrast MRI data and are used together with a respiratory model. Lumped parameter (RCR) boundary conditions are used at the outlets. This study is the first to introduce variable elastic properties for the different areas of the TCPC, including a Gore-Tex conduit. Quantities such as wall shear stresses and pressures at critical junctions are extracted from the simulation and are compared with pressure tracings from clinical data as well as with rigid wall simulations.

  8. KSC-99pp0834

    NASA Image and Video Library

    1999-07-16

    KSC's Director of Public Affairs Joe Gordon (left) applauds as Ed Gormel and Chris Fairey are named recipients of the Hammer Award at a special presentation in the IMAX 2 Theater in the Kennedy Space Center Visitor Complex. Presenting the award is Morley Winograd (at the podium), director of the National Partnership for Reinventing Government. The Hammer Award is Vice President Al Gore's special recognition of teams of federal employees who have made significant contributions in support of the principles of the National Partnership for Reinventing Government. This Hammer Award acknowledges the accomplishments of a joint NASA and Air Force team that established the Joint Base Operations and Support Contract (J-BOSC) Source Evaluation Board (SEB). Gormel and Fairey are co-chairs of the SEB. The team developed and implemented the acquisition strategy for establishing a single set of base operations and support service requirements for KSC, Cape Canaveral Air Station and Patrick Air Force Base

  9. The Hammer Award is presented to KSC and 45th Space Wing.

    NASA Technical Reports Server (NTRS)

    1999-01-01

    KSC's Director of Public Affairs Joe Gordon (left) applauds as Ed Gormel and Chris Fairey are named recipients of the Hammer Award at a special presentation in the IMAX 2 Theater in the Kennedy Space Center Visitor Complex. Presenting the award is Morley Winograd (at the podium), director of the National Partnership for Reinventing Government. The Hammer Award is Vice President Al Gore's special recognition of teams of federal employees who have made significant contributions in support of the principles of the National Partnership for Reinventing Government. This Hammer Award acknowledges the accomplishments of a joint NASA and Air Force team that established the Joint Base Operations and Support Contract (J-BOSC) Source Evaluation Board (SEB). Gormel and Fairey are co-chairs of the SEB. The team developed and implemented the acquisition strategy for establishing a single set of base operations and support service requirements for KSC, Cape Canaveral Air Station and Patrick Air Force Base.

  10. The Hammer Award is presented to KSC and 45th Space Wing.

    NASA Technical Reports Server (NTRS)

    1999-01-01

    Commander of the Air Force Space Command, General Richard B. Myers (left) joins Ed Gormel (center) and Commander of the 45th Space Wing Brig. Gen. F. Randall Starbuck (right) after the presentation of the Hammer Award. The Hammer Award is Vice President Al Gore's special recognition of teams of federal employees who have made significant contributions in support of the principles of the National Partnership for Reinventing Government. Morley Winograd, director of the National Partnership for Reinventing Government, presented the award to the Joint Base Operations and Support Contract (J-BOSC) Source Evaluation Board (SEB). Gormel is a co-chair of the SEB. This Hammer Award acknowledges the accomplishments of a joint NASA and Air Force team that established the J-BOSC SEB. The team developed and implemented the acquisition strategy for establishing a single set of base operations and support service requirements for KSC, Cape Canaveral Air Station and Patrick Air Force Base.

  11. Time to quit my day job? My not-so-quiet crusade to become the funniest climate scientist at NASA

    NASA Astrophysics Data System (ADS)

    Schmidt, G. A.; Pulwarty, R. S.; Willis, J. K.

    2017-12-01

    The first time I showed a funny slide at AGU, it bombed. Badly. "What causes global warming?" I asked an audience of 100 learned colleagues. I pushed the space bar. Up popped a photo-shopped picture of a gigantic Al Gore breathing fire on the Earth…. Silence. Complete silence. Even the crickets were judging me. Since that time, I've completed an entire curriculum at a world-renowned school of funny (The Conservatory Program at Second City, Hollywood), written sketch shows, told funny stories, acted in short and full-length feature films, and practiced. Mostly practiced. A lot. So, did I get better at making global warming funny? Come find out. In this presentation I will tell some jokes, talk about my experience trying to use comedy in public communications, and show at least one video that educates people about climate change, and is also funny. At least—I think it's funny.

  12. A Unique Fatal Moose Attack Mimicking Homicide.

    PubMed

    Gudmannsson, Petur; Berge, Johan; Druid, Henrik; Ericsson, Göran; Eriksson, Anders

    2018-03-01

    Fatalities caused by animal attacks are rare, but have the potential to mimic homicide. We present a case in which a moose attacked and killed a woman who was walking her dog in a forest. Autopsy showed widespread blunt trauma with a large laceration on one leg in which blades of grass were embedded. Flail chest was the cause of death. The case was initially conceived as homicide by means of a riding lawn mower. A review of the case by moose experts and analyses of biological trace material that proved to originate from moose, established the true source of injury. The dog probably provoked a moose, which, in response, stomped and gored the victim to death. The injuries resembled those previously reported from attacks by cattle and water buffalo. Fatal moose attacks constitute an extremely rare threat in boreal areas, but can be considered in traumatic deaths of unknown cause. © 2017 American Academy of Forensic Sciences.

  13. 2D photoacoustic scanning imaging with a single pulsed laser diode excitation

    NASA Astrophysics Data System (ADS)

    Chen, Xuegang; Li, Changwei; Zeng, Lvming; Liu, Guodong; Huang, Zhen; Ren, Zhong

    2012-03-01

    A portable near-infrared photoacoustic scanning imaging system has been developed with a single pulsed laser diode, which was integrated with an optical lens system to straightforward boost the laser energy density for photoacoustic generation. The 905 nm laser diode provides a maximum energy output of 14 μJ within 100 ns pulse duration, and the pulse repetition frequency rate is 0.8 KHz. As a possible alternative light source, the preliminary 2D photoacoustic results primely correspond with the test phantoms of umbonate extravasated gore and knotted blood vessel network. The photoacoustic SNR can reach 20.6+/-1.2 dB while signal averaging reduces to 128 pulses from thousands to tens of thousands times, and the signal acquisition time accelerates to less than 0.2 s in each A-scan, especially the volume of the total radiation source is only 10 × 3 × 3 cm3. It demonstrated that the pulsed semiconductor laser could be a candidate of photoacoustic equipment for daily clinical application.

  14. Temporary suspension of acute facial paralysis using the S-S Cable Suture (Medical U&A, Tokyo, Japan).

    PubMed

    Ozaki, Mine; Takushima, Akihiko; Momosawa, Akira; Kurita, Masakazu; Harii, Kiyonori

    2008-07-01

    For a treatment of facial paralysis, suture suspension of soft tissue is considered effective due to its less invasiveness and relatively simple technique, with minimal bruising and rapid recovery. However, suture suspension effect may not last for a long period of time. We obtained good outcome with temporary static suture suspension in 5 cases of severe facial paralysis in the intervening period between the onset of paralysis and expected spontaneous recovery. We used the S-S Cable Suture (Medical U&A, Tokyo, Japan), which was based on the modification of previously established method using the Gore-Tex cable suture originally reported by Sasaki et al in 2002. Because of the ease of technique and relatively strong lifting capability of the malar pad, we recommend it as a useful procedure for a patient suffering acute facial paralysis with possible spontaneous recovery for an improved quality of life by the quick elimination of facial distortion.

  15. The New Zealand gravimetric quasigeoid model 2017 that incorporates nationwide airborne gravimetry

    NASA Astrophysics Data System (ADS)

    McCubbine, J. C.; Amos, M. J.; Tontini, F. C.; Smith, E.; Winefied, R.; Stagpoole, V.; Featherstone, W. E.

    2017-12-01

    A one arc-minute resolution gravimetric quasigeoid model has been computed for New Zealand, covering the region 25°S -60°S and 160°E -170°W . It was calculated by Wong and Gore modified Stokes integration using the remove-compute-restore technique with the EIGEN-6C4 global gravity model as the reference field. The gridded gravity data used for the computation consisted of 40,677 land gravity observations, satellite altimetry-derived marine gravity anomalies, historical shipborne marine gravity observations and, importantly, approximately one million new airborne gravity observations. The airborne data were collected with the specific intention of reinforcing the shortcomings of the existing data in areas of rough topography inaccessible to land gravimetry and in coastal areas where shipborne gravimetry cannot be collected and altimeter-derived gravity anomalies are generally poor. The new quasigeoid has a nominal precision of ± 48 mm on comparison with GPS-levelling data, which is approximately 14 mm less than its predecessor NZGeoid09.

  16. Capturing Requirements for Autonomous Spacecraft with Autonomy Requirements Engineering

    NASA Astrophysics Data System (ADS)

    Vassev, Emil; Hinchey, Mike

    2014-08-01

    The Autonomy Requirements Engineering (ARE) approach has been developed by Lero - the Irish Software Engineering Research Center within the mandate of a joint project with ESA, the European Space Agency. The approach is intended to help engineers develop missions for unmanned exploration, often with limited or no human control. Such robotics space missions rely on the most recent advances in automation and robotic technologies where autonomy and autonomic computing principles drive the design and implementation of unmanned spacecraft [1]. To tackle the integration and promotion of autonomy in software-intensive systems, ARE combines generic autonomy requirements (GAR) with goal-oriented requirements engineering (GORE). Using this approach, software engineers can determine what autonomic features to develop for a particular system (e.g., a space mission) as well as what artifacts that process might generate (e.g., goals models, requirements specification, etc.). The inputs required by this approach are the mission goals and the domain-specific GAR reflecting specifics of the mission class (e.g., interplanetary missions).

  17. Experimental measurement of flexion-extension movement in normal and corpse prosthetic elbow joint.

    PubMed

    TarniŢă, Daniela; TarniŢă, DănuŢ Nicolae

    2016-01-01

    This paper presents a comparative experimental study of flexion-extension movement in healthy elbow and in the prosthetic elbow joint fixed on an original experimental bench. Measurements were carried out in order to validate the functional morphology and a new elbow prosthesis type ball head. The three-dimensional (3D) model and the physical prototype of our experimental bench used to test elbow endoprosthesis at flexion-extension and pronation-supination movements is presented. The measurements were carried out on a group of nine healthy subjects and on the prosthetic corpse elbow, the experimental data being obtained for flexion-extension movement cycles. Experimental data for the two different flexion-extension tests for the nine subjects and for the corpse prosthetic elbow were acquired using SimiMotion video system. Experimental data were processed statistically. The corresponding graphs were obtained for all subjects in the experimental group, and for corpse prosthetic elbow for both flexion-extension tests. The statistical analysis has proved that the flexion angles of healthy elbows were significantly close to the values measured at the prosthetic elbow fixed on the experimental bench. The studied elbow prosthesis manages to re-establish the mobility for the elbow joint as close to the normal one.

  18. Periosteal pseudotumor in complex total knee arthroplasty resembling a neoplastic process.

    PubMed

    Chowdhry, Madhav; Dipane, Matthew V; McPherson, Edward J

    2018-05-18

    This case report describes in detail an erosive distal diaphyseal pseudotumor that occurred 6 years after a complex endoprosthetic hinge total knee arthroplasty (TKA). A female patient had conversion of a knee fusion to an endoprosthetic hinge TKA at the age of 62. At her scheduled 6-year follow-up, she presented with mild distal thigh pain and radiographs showing a 6-7 cm erosive lytic diaphyseal lesion that looked very suspicious for a neoplastic process. An en bloc resection of the distal femur and femoral endoprosthesis was performed. Histologic review showed the mass to be a pseudotumor with the wear debris emanating from within the femoral canal due to distal stem loosening. We deduce that mechanized stem abrasion created microscopic titanium alloy particles that escaped via a small diaphyseal crack and stimulated an inflammatory response resulting in a periosteal erosive pseudotumor. The main lesson of this report is that, in the face of a joint replacement surgery of the knee, pseudotumor formation is a more likely diagnosis than a neoplastic process when encountering an expanding bony mass. Thus, a biopsy prior to en bloc resection, would be our recommended course of action any time a suspicious mass is encountered close to a TKA.

  19. [Combined spinal epidural anesthesia during endoprosthetic surgeries for bone tumors in old-age children].

    PubMed

    Matinian, N V; Saltanov, A I

    2005-01-01

    Thirty-five patients (ASA II-III) aged 12 to 17 years, diagnosed as having osteogenic sarcoma and Ewing's sarcoma localizing in the femur and tibia, were examined. Surgery was performed as sectoral resection of the affected bone along with knee joint endoprosthesis. Surgical intervention was made under combined spinal and epidural anesthesia (CSEA) with sedation, by using the methods for exact dosing of propofol (6-4 mg/kg x h). During intervention, a child's respiration remains is kept spontaneous with oxygen insufflation through a nasal catheter. CSEA was performed in two-segmental fashion. The epidural space was first catheterized. After administration of a test dose, 0.5% marcaine spinal was injected into dermatomas below the subarachnoidal space, depending on body weight (3.0-4.0 ml). Sensory blockade developed following 3-5 min and lasted 90-120 min, thereafter a local anesthetic (bupivacaine) or its mixture plus promedole was epidurally administered. ??Anesthesia was effective in all cases, motor blockade. During surgery, there was a moderate arterial hypotension that did not require the use of vasopressors. The acid-alkali balance suggested the adequacy of spontaneous respiration. The only significant complication we observed was atony of the bladder that requires its catheterization till the following day. An epidural catheter makes it possible to effect adequate postoperative analgesia.

  20. [Implementation of the EndoCert system for certification of arthroplasty centers. Experiences from the pilot phase].

    PubMed

    Haas, H; Mittelmeier, W

    2014-06-01

    EndoCert is an initiative of the Deutschen Gesellschaft für Orthopädie und Orthopädische Chirurgie (DGOOC, German Society for Orthopedics and Orthopedic Surgery) which has been available since October 2012 and is the first system worldwide for certification of specialized arthroplasty centers. Before implementation of this certification concept two sequential pilot phases were carried out with representative treatment institutions. The results from these pilot clinics are presented with respect to quality improvement effects. Early effects on the quality of treatment have been achieved by rectification of nonconformities determined in the audit with respect to structural and process quality. A total of 172 nonconformities found in the 23 participating pilot clinics could be rectified. Long-term effects on the quality of results will in future be analyzed in cooperation with the German endoprosthesis register (EPRD) and by accompanying evaluations. A close feedback of the collated experiences and results to the certification committee, which is responsible for the procedure together with the DGOOC, allows continuous further development of the system EndoCert represents a substantial step towards a nationwide safety and improvement of the quality in arthroplasty treatment within the preoperative, perioperative and postoperative framework and can in future represent a decisive tool together with the EPRD in quality management.

  1. Design, analysis and verification of a knee joint oncological prosthesis finite element model.

    PubMed

    Zach, Lukáš; Kunčická, Lenka; Růžička, Pavel; Kocich, Radim

    2014-11-01

    The aim of this paper was to design a finite element model for a hinged PROSPON oncological knee endoprosthesis and to verify the model by comparison with ankle flexion angle using knee-bending experimental data obtained previously. Visible Human Project CT scans were used to create a general lower extremity bones model and to compose a 3D CAD knee joint model to which muscles and ligaments were added. Into the assembly the designed finite element PROSPON prosthesis model was integrated and an analysis focused on the PEEK-OPTIMA hinge pin bushing stress state was carried out. To confirm the stress state analysis results, contact pressure was investigated. The analysis was performed in the knee-bending position within 15.4-69.4° hip joint flexion range. The results showed that the maximum stress achieved during the analysis (46.6 MPa) did not exceed the yield strength of the material (90 MPa); the condition of plastic stability was therefore met. The stress state analysis results were confirmed by the distribution of contact pressure during knee-bending. The applicability of our designed finite element model for the real implant behaviour prediction was proven on the basis of good correlation of the analytical and experimental ankle flexion angle data. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Biodegradable implants for Pipkin fractures.

    PubMed

    Prokop, Axel; Helling, Hanns-Joachim; Hahn, Ulrich; Udomkaewkanjana, Chira; Rehm, Klaus Emil

    2005-03-01

    The current study was designed to clarify whether biodegradable poly-L/DL lactide pins provide an operative alternative for fixation of Pipkin fractures. Nine patients with Pipkin fractures (one with Pipkin Type I, one with Pipkin Type II, and seven with Pipkin Type IV fractures) were treated surgically between 1996 and 2002. In all patients, the femoral head fractures were fixed with biodegradable, 2.7-mm and 2.0-mm polylactide pins. Eight patients were followed up for an average of 54.2 months. One patient died before the final followup. Eight fractures healed uneventfully. In one patient, a persisting femoral head defect led to posttraumatic arthritis requiring insertion of a femoral endoprosthesis at 1 year. The average range of motion of the affected hips of all patients at followup was 109 degrees -0 degrees -0 degrees in flexion and extension. External and internal rotation averaged 37 degrees -0 degrees -29 degrees . One patient had Brooker Grade I heterotopic ossification develop, and another had a Grade II heterotopic develop. Merle d'Aubigne and Postel ratings showed two excellent and five satisfactory results (average score, 13.1). Adverse effects from the polylactide implants were not observed. Pipkin fractures can be fixed successfully with biodegradable polylactide pins.

  3. International Volcanological Field School in Kamchatka and Alaska: Experiencing Language, Culture, Environment, and Active Volcanoes

    NASA Astrophysics Data System (ADS)

    Eichelberger, J. C.; Gordeev, E.; Ivanov, B.; Izbekov, P.; Kasahara, M.; Melnikov, D.; Selyangin, O.; Vesna, Y.

    2003-12-01

    The Kamchatka State University of Education, University of Alaska Fairbanks, and Hokkaido University are developing an international field school focused on explosive volcanism of the North Pacific. An experimental first session was held on Mutnovsky and Gorely Volcanoes in Kamchatka during August 2003. Objectives of the school are to:(1) Acquaint students with the chemical and physical processes of explosive volcanism, through first-hand experience with some of the most spectacular volcanic features on Earth; (2) Expose students to different concepts and approaches to volcanology; (3) Expand students' ability to function in a harsh environment and to bridge barriers in language and culture; (4) Build long-lasting collaborations in research among students and in teaching and research among faculty in the North Pacific region. Both undergraduate and graduate students from Russia, the United States, and Japan participated. The school was based at a mountain hut situated between Gorely and Mutnovsky Volcanoes and accessible by all-terrain truck. Day trips were conducted to summit craters of both volcanoes, flank lava flows, fumarole fields, ignimbrite exposures, and a geothermal area and power plant. During the evenings and on days of bad weather, the school faculty conducted lectures on various topics of volcanology in either Russian or English, with translation. Although subjects were taught at the undergraduate level, lectures led to further discussion with more advanced students. Graduate students participated by describing their research activities to the undergraduates. A final session at a geophysical field station permitted demonstration of instrumentation and presentations requiring sophisticated graphics in more comfortable surroundings. Plans are underway to make this school an annual offering for academic credit in the Valley of Ten Thousand Smokes, Alaska and in Kamchatka. The course will be targeted at undergraduates with a strong interest in and

  4. Durability of hand-sewn valves in the right ventricular outlet.

    PubMed

    Nunn, Graham R; Bennetts, Jayme; Onikul, Ella

    2008-08-01

    The objective was to compare the medium- and long-term outcomes for pericardial monocusp valves, polytetrafluoroethylene (Gore-Tex, WL Gore and Associates Inc, Flagstaff, Ariz) 0.1-mm monocusp valves, and bileaflet 0.l-mm polytetrafluoroethylene valves and their efficiency in the right ventricular outlet. We reviewed all hand-sewn right ventricular outlet valves created by the author (Graham R. Nunn) in the setting of repaired tetralogy of Fallot or equivalent right ventricular outlet pathology when the native pulmonary valve could not be preserved. The valves were assessed by serial transthoracic echocardiography and more recently by magnetic resonance imaging angiography for late valve function. The bileaflet polytetrafluoroethylene valves were constructed in a standardized fashion from a semicircle of 0.1-mm polytetrafluoroethylene (the radius of which equaled the length of the outflow tract incision) that gave a lengthened free edge to the leaflets, central fixation of the free edge posteriorly just proximal to the branch pulmonary arteries, and generous augmentation of the outflow tract with polytetrafluoroethylene patch-plasty. The bileaflet configuration shortens the closing time against the posterior wall, and the leaflets are forced to maintain their configuration without prolapse into the right ventricular outlet. The valve can be generously oversized in young children to try to avoid the need for replacement. A total of 54 patients met the selection criteria--22 patients received fresh autologous pericardial monocusps, 7 patients received polytetrafluoroethylene (0.1-mm) monocusps, and 25 patients received bileaflet polytetrafluoroethylene (0.1-mm) outlet valves. The pericardial valves have the longest follow-up, and all valves developed free pulmonary incompetence. Polytetrafluoroethylene monocusps had reliable competence early after surgery but progressed to pulmonary incompetence. The bileaflet polytetrafluoroethylene (0.1-mm) valves have remained

  5. Combined Resection of the Liver and Inferior Vena Cava for Hepatic Malignancy

    PubMed Central

    Hemming, Alan W.; Reed, Alan I.; Langham, Max R.; Fujita, Shiro; Howard, Richard J.

    2004-01-01

    Objective: The objective of this paper is to review the results of combined resection of the liver and inferior vena cava for hepatic malignancy. The morbidity and mortality along with preliminary survival data are assessed in order to determine the utility of this aggressive approach to otherwise unresectable tumors. Summary Background Data: Involvement of the inferior vena cava has traditionally been considered a contraindication to resection for advanced tumors of the liver because the surgical risks are high and the long-term prognosis is poor. Progress in liver surgery allows resection in some cases. Methods: Twenty-two patients undergoing hepatic resection from 1997 to 2003, that also required resection and reconstruction of the inferior vena cava (IVC), were reviewed. The median age was 49 years (range 2 to 68 years). Resections were carried out for: hepatocellular carcinoma (n = 6), colorectal metastases (n = 6), cholangiocarcinoma (n = 5), gastrointestinal stromal tumor (n = 2), hepatoblastoma (n = 2), and squamous cell carcinoma in 1 patient. Liver resections performed included 13 right trisegmentectomies, 6 right lobectomies extended to include the caudate lobe, and 3 left trisegmentectomies. Complex ex vivo procedures were performed in 2 cases using venovenous bypass while the other 20 cases were performed using varying degrees of vascular isolation. In situ cold perfusion of the liver was used in 1 case. The IVC was reconstructed with ringed Gore-Tex tube graft (n = 14), primarily (n = 6), or with Gore-Tex patches (n = 2). Results: There were 2 perioperative deaths (9%). One cirrhotic patient died of liver failure 3 weeks post operatively and 1 patient with cholangiocarcinoma died of pulmonary hemorrhage secondary to a cavitating pulmonary infection after aspiration pneumonia 6 weeks after resection. Six patients had evidence of postoperative liver failure that resolved with supportive management and 2 patients required temporary dialysis. All vascular

  6. Demonstration of the AGI Universal Samplers (F.K.A. the GORE (registered trademark) Modules) for Passive Sampling of Groundwater

    DTIC Science & Technology

    2014-03-01

    Coefficient from Water into the Sorbent KOW Octanol-Water Partition Coefficient LF Low Flow LNAPL Light Non-aqueous Phase Liquid LTM Long-Term...Once in the vapor phase, the molecule can then diffuse through the mem- ERDC/CRREL TR-14-4 5 brane while liquid water is prevented from passing...remediation at this site was conducted in two phases. Phase I consisted of vertical contamina- tion profiling followed by the in situ injection of an

  7. Non-destructive investigation of a time capsule using neutron radiography and X-ray fluorescence

    NASA Astrophysics Data System (ADS)

    MacDonald, B. L.; Vanderstelt, J.; O'Meara, J.; McNeill, F. E.

    2016-01-01

    Non-destructive analytical techniques are becoming increasingly important for the study of objects of cultural heritage interest. This study applied two techniques: X-ray fluorescence and neutron radiography, for the investigation of a capped, tubular metal object recovered from an urban construction site in Gore Park, Hamilton, Canada. The site is an urban park containing a World War I commemorative monument that underwent renovation and relocation. Historical documentation suggested that the object buried underneath the monument was a time capsule containing a paper document listing the names of 1800 Canadians who died during WWI. The purpose of this study was to assess the condition of the object, and to verify if it was what the historical records purported. XRF analysis was used to characterize the elemental composition of the metal artifact, while neutron radiography revealed that its contents were congruent with historical records and remained intact after being interred for 91 years. Results of this study demonstrate the value of non-destructive techniques for the analysis and preservation of cultural heritage.

  8. Embolization of the Systemic Arterial Supply via a Detachable Silicon Balloon in a Child with Scimitar Syndrome

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sahin, Sinan; Celebi, Ahmet; Yalcin, Yalim

    2005-04-15

    Scimitar syndrome is a rare congenital disorder. It is characterized by partial or total abnormal venous drainage of the right lung into the inferior vena cava, which is often associated with anomalous systemic arterial supply to the right lung, congenital cardiac anomalies, hypoplasia of the right lung and bronchial anomalies. Symptoms depend on the degree of the shunt and severity of the associated anomalies, which determine the treatment. We present a 6-year-old boy who was diagnosed as having the adult form of scimitar syndrome during evaluation for recurrent pulmonary infections, and underwent embolization with a detachable silicon balloon of themore » anomalous systemic arterial supply from the abdominal aorta to the right lower lung lobe. Successful elective surgery was performed 6 months later, in which right pulmonary veins were directed to the left atrium using a Gore-Tex patch by creating an intra-atrial tunnel. The patient has been symptom-free period during 6 months of follow-up, which supports the idea that recurrent pulmonary infections can be eliminated by embolization of the anomalous arterial supply.« less

  9. Radial force measurement of endovascular stents: Influence of stent design and diameter.

    PubMed

    Matsumoto, Takuya; Matsubara, Yutaka; Aoyagi, Yukihiko; Matsuda, Daisuke; Okadome, Jun; Morisaki, Koichi; Inoue, Kentarou; Tanaka, Shinichi; Ohkusa, Tomoko; Maehara, Yoshihiko

    2016-04-01

    Angioplasty and endovascular stent placement is used in case to rescue the coverage of main branches to supply blood to brain from aortic arch in thoracic endovascular aortic repair. This study assessed mechanical properties, especially differences in radial force, of different endovascular and thoracic stents. We analyzed the radial force of three stent models (Epic, E-Luminexx and SMART) stents using radial force-tester method in single or overlapping conditions. We also analyzed radial force in three thoracic stents using Mylar film testing method: conformable Gore-TAG, Relay, and Valiant Thoracic Stent Graft. Overlapping SMART stents had greater radial force than overlapping Epic or Luminexx stents (P < 0.01). The radial force of the thoracic stents was greater than that of all three endovascular stents (P < 0.01). Differences in radial force depend on types of stents, site of deployment, and layer characteristics. In clinical settings, an understanding of the mechanical characteristics, including radial force, is important in choosing a stent for each patient. © The Author(s) 2015.

  10. Vortex formation in a complex plasma

    NASA Astrophysics Data System (ADS)

    Ishihara, Osamu

    Complex plasma experiments in ground-based laboratories as well as in microgravity conditions have shown the formation of vortex structures in various conditions (e.g., 1,2,3,4). The vortex structures formed in a complex plasma are visible by naked eyes with the help of irradiating laser and the individual dust particles in the structure give us the opportunity to study detailed physics of the commonly observed natural phenomena known such as tornadoes, typhoons, hurricanes and dust devils. Based on the Navier-Stokes equation with proper complex plasma conditions we analyze as much as possible in a universal way the vortex structure and clarifies the role of the controlling parameters like flow velocity and external magnetic field. 1. G. E. Morfill,H. M. Thomas, U. Konopka,H. Rothermel, M. Zuzic, A. Ivlev, and J. Goree, Phys,. Rev. Lett. 83, 1598 (1999). 2. E. Nebbat and R. Annou, Phys. Plasmas 17, 093702 (2010). 3. Y. Saitou and O. Ishihara, Phys. Rev. Lett. 111, 185003 (2013). 4. V. N. Tsytovich and N. G. Gusein-zade, Plasma Phys. Rep. 39, 515 (2013).

  11. [TECHNIQUES IN MITRAL VALVE REPAIR VIA A MINIMALLY INVASIVE APPROACH].

    PubMed

    Ito, Toshiaki

    2016-03-01

    In mitral valve repair via a minimally invasive approach, resection of the leaflet is technically demanding compared with that in the standard approach. For resection and suture repair of the posterior leaflet, premarking of incision lines is recommended for precise resection. As an alternative to resection and suture, the leaflet-folding technique is also recommended. For correction of prolapse of the anterior leaflet, neochordae placement with the loop technique is easy to perform. Premeasurement with transesophageal echocardiography or intraoperative measurement using a replica of artificial chordae is useful to determine the appropriate length of the loops. Fine-tuning of the length of neochordae is possible by adding a secondary fixation point on the leaflet if the loop is too long. If the loop is too short, a CV5 Gore-Tex suture can be passed through the loop and loosely tied several times to stack the knots, with subsequent fixation to the edge of the leaflet. Finally, skill in the mitral valve replacement technique is necessary as a back-up for surgeons who perform minimally invasive mitral valve repair.

  12. Chronic swine instrumentation techniques utilizing the GOR-REX peritoneal catheter

    NASA Astrophysics Data System (ADS)

    Gray, C. C.; White, F. C.; Crisman, R. P.; Wisniewski, J.; McKirnan, D.

    1985-05-01

    The GORE-TEX peritoneal catheter interface is an effective skin interface device for many types of instrumentation in the swine. When properly utilized, the interface allows the development of a stable and effective biological seal which will reduce or eliminate sinus tract formation and resultant systemic infection. The interface is suitable for running any wire or catheter (up to about 2.5mm diameter) through the integument of the animal, thus increasing the possibilities for chronic instrumentation while maintaining a healthy animal. The lack of evidence of any growth phenomenon acting to extrude the interface segment, similar to that observed using other synthetic materials, and the superior biological seal which the interface develops, may allow many chronic studies which were previously not feasible. Using special catheter adapter stubs and an intermittent infusion plug, a sterile, sealed catheter system has decreased the possibilities for introducing pathogens while allowing ready access to the blood stream. Detailed descriptions of surgical implantation techniques and catheter set up and maintenance techniques are included.

  13. Endovascular Repair of an Actively Hemorrhaging Stab Wound Injury to the Abdominal Aorta

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hussain, Qasim; Maleux, Geert, E-mail: geert.maleux@uz.kuleuven.ac.be; Heye, Sam

    Traumatic injury of the abdominal aorta is rare and potentially lethal (Yeh et al., J Vasc Surg 42(5):1007-1009, 2005; Chicos et al., Chirurgia (Bucur) 102(2):237-240, 2007) as it can result in major retroperitoneal hemorrhage, requiring an urgent open surgery. In case of concomitant bowel injury or other conditions of hostile abdomen, endovascular repair can be an alternative treatment. This case report deals with a 50-year-old man presenting at the emergency ward with three stab wounds: two in the abdomen and one in the chest. During explorative laparotomy, liver laceration and bowel perforation were repaired. One day later, abdominal CT-scan revealedmore » an additional retroperitoneal hematoma associated with an aortic pseudoaneurysm, located anteriorly 3 cm above the aortic bifurcation. Because of the risk of graft infection, an endovascular repair of the aortic injury using a Gore excluder stent-graft was performed. Radiological and clinical follow-up revealed a gradual shrinkage of the pseudo-aneurysm and no sign of graft infection at two years' follow-up.« less

  14. KSC-99pp0837

    NASA Image and Video Library

    1999-07-16

    At a special presentation in the IMAX 2 Theater in the Kennedy Space Center Visitor Complex, the Hammer Award is presented to Kennedy Space Center and the 45th Space Wing. Present for the awards are (left to right) Commander of the Air Force Space Command General Richard B. Myers, Ed Gormel, Chris Fairey, NASA Administrator Daniel Goldin, and Director of the National Partnership for Reinventing Government, Morley Winograd, who presented the award. The Hammer Award is Vice President Al Gore's special recognition of teams of federal employees who have made significant contributions in support of the principles of the National Partnership for Reinventing Government. This Hammer Award acknowledges the accomplishments of a joint NASA and Air Force team that established the Joint Base Operations and Support Contract (J-BOSC) Source Evaluation Board (SEB). Gormel and Fairey are co-chairs of the SEB. The team developed and implemented the acquisition strategy for establishing a single set of base operations and support service requirements for KSC, Cape Canaveral Air Station and Patrick Air Force Base

  15. A mathematical model for predicting the life of polymer electrolyte fuel cell membranes subjected to hydration cycling

    NASA Astrophysics Data System (ADS)

    Burlatsky, S. F.; Gummalla, M.; O'Neill, J.; Atrazhev, V. V.; Varyukhin, A. N.; Dmitriev, D. V.; Erikhman, N. S.

    2012-10-01

    Under typical Polymer Electrolyte Membrane Fuel Cell (PEMFC) fuel cell operating conditions, part of the membrane electrode assembly is subjected to humidity cycling due to variation of inlet gas RH and/or flow rate. Cyclic membrane hydration/dehydration would cause cyclic swelling/shrinking of the unconstrained membrane. In a constrained membrane, it causes cyclic stress resulting in mechanical failure in the area adjacent to the gas inlet. A mathematical modeling framework for prediction of the lifetime of a PEMFC membrane subjected to hydration cycling is developed in this paper. The model predicts membrane lifetime as a function of RH cycling amplitude and membrane mechanical properties. The modeling framework consists of three model components: a fuel cell RH distribution model, a hydration/dehydration induced stress model that predicts stress distribution in the membrane, and a damage accrual model that predicts membrane lifetime. Short descriptions of the model components along with overall framework are presented in the paper. The model was used for lifetime prediction of a GORE-SELECT membrane.

  16. Endovascular repair of an actively hemorrhaging stab wound injury to the abdominal aorta.

    PubMed

    Hussain, Qasim; Maleux, Geert; Heye, Sam; Fourneau, Inge

    2008-01-01

    Traumatic injury of the abdominal aorta is rare and potentially lethal (Yeh et al., J Vasc Surg 42(5):1007-1009, 2005; Chicos et al., Chirurgia (Bucur) 102(2):237-240, 2007) as it can result in major retroperitoneal hemorrhage, requiring an urgent open surgery. In case of concomitant bowel injury or other conditions of hostile abdomen, endovascular repair can be an alternative treatment. This case report deals with a 50-year-old man presenting at the emergency ward with three stab wounds: two in the abdomen and one in the chest. During explorative laparotomy, liver laceration and bowel perforation were repaired. One day later, abdominal CT-scan revealed an additional retroperitoneal hematoma associated with an aortic pseudoaneurysm, located anteriorly 3 cm above the aortic bifurcation. Because of the risk of graft infection, an endovascular repair of the aortic injury using a Gore excluder stent-graft was performed. Radiological and clinical follow-up revealed a gradual shrinkage of the pseudo-aneurysm and no sign of graft infection at two years' follow-up.

  17. Cooperation, cheating, and collapse in microbial populations

    NASA Astrophysics Data System (ADS)

    Gore, Jeff

    2012-02-01

    Natural populations can suffer catastrophic collapse in response to small changes in environmental conditions, and recovery after such a collapse can be exceedingly difficult. We have used laboratory yeast populations to study proposed early warning signals of impending extinction. Yeast cooperatively breakdown the sugar sucrose, meaning that there is a minimum number of cells required to sustain the population. We have demonstrated experimentally that the fluctuations in the population size increase in magnitude and become slower as the population approaches collapse. The cooperative nature of yeast growth on sucrose suggests that the population may be susceptible to cheater cells, which do not contribute to the public good and instead merely take advantage of the cooperative cells. We have confirmed this possibility experimentally by using a cheater yeast strain that lacks the gene encoding the cooperative behavior [1]. However, recent results in the lab demonstrate that the presence of a bacterial competitor may drive cooperation within the yeast population.[4pt] [1] Gore et al, Nature 459, 253 -- 256 (2009)

  18. [Technology of cementless hip endoprosthetics].

    PubMed

    Ungethüm, M; Blömer, W

    1987-06-01

    The success achieved with non-cemented hip arthroplasty depends mainly on the stability of the fixation, the quality of the stabilizing bone being just as important as favourable biomechanical conditions. The results of the intensive research and development with respect to the particular features of a non-cemented hip endoprosthesis can be divided into the following basic categories: Biomechanical aspects with special reference to bone related to the design of the prosthesis; material characteristics, such as fatigue strength, tribology, corrosion resistance, and biocompatibility; and development of new materials and coatings to permit direct bonding of implant and bone. With regard to the stem of hip prostheses, the different design parameters of various types are examined to determine their typical design characteristics, such as bearing surface of the collar, geometry of cross section, anatomically adapted shaping, and surface of the implant forming the contact with the bone. The latter can be divided into macroprofiles and macro- and micro-porous coated surfaces. On the other hand, the methods of cementless fixation of acetabular cups can be primarily divided into conical and spherical screw fixation and pegged fixation with additional macroprofiles of porous surfaces. In a separate study of the biomechanical aspects of screwed sockets, the special importance of socket shape and thread geometry are presented with reference to primary stability and long-term fixation of prostheses.

  19. Modification of Ti6Al4V surface by diazonium compounds

    NASA Astrophysics Data System (ADS)

    Sandomierski, Mariusz; Buchwald, Tomasz; Strzemiecka, Beata; Voelkel, Adam

    2018-02-01

    Ti6Al4V alloy is the most commonly used in orthopedic industry as an endoprosthesis. Ti6Al4V exhibits good mechanical properties, except the abrasion resistance. Surface modification of Ti6Al4V in order to obtain organic layer, and then the attachment of the polymer, can allow for overcoming this problem. The aim of the work was the modification of Ti6Al4V surface by diazonium compounds: salt or cation generated in situ and examine the influence of the reducing agent - ascorbic acid, and the temperature of reaction on modification process. Moreover, the simulated body fluid was used for the assessment of the organic layer stability on Ti6Al4V surface. The evaluation of the modification was carried out using the following methods: Raman microspectroscopy, scanning electron microscopy and energy-dispersive X-ray spectroscopy. Higher temperature of modification by 4-hydroxymethylbenzenediazonium cation, provides the largest amount of organic layer on the Ti6Al4V alloy. In the case of the Ti6Al4V modified by Variamine Blue B salt, the amount of organic layer is not dependent on the reaction condition. Moreover, the ascorbic acid and the presence of TiO2 does not effect on the modification. The modified surface is completely coated with the organic layer which is stable in simulated body fluid.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saad, Wael E. A., E-mail: wspikes@yahoo.com; Dasgupta, Niloy; Lippert, Allison J.

    To characterize extrahepatic pseudoaneurysm regarding incidence and etiology and determine the effectiveness of endovascular management. A retrospective audit of 1,857 liver transplants in two institutions was performed (1996-2009). Recipients' demographics, clinical presentation, transplant type, biliary anastomosis, and presence of biliary endoprostheses were noted. Pseudoaneurysms were classified into iatrogenic (associated with biliary endoprosthesis or angioplasty) or spontaneous extrahepatic pseudoaneurysms. Spontaneous and iatrogenic pseudoaneurysms were compared for time from transplant, presenting symptoms, location in the arterial anatomy, and 3-month graft survival. Arterial patency and 6-month graft survival were calculated. Twenty pseudoaneurysms were found (1.1 %, 20/1,857): 9 (0.5 % of transplants, 9/1,857)more » were spontaneous and 11 (0.6 % of transplants, 11/1,857) were 'iatrogenic' (due to minimally invasive procedures: 4 angioplasty and 7 biliary endoprostheses). Sixty percent (12/20) underwent endovascular management (4 coil embolization and 8 stent-grafts). Technical success was 83 % (10/12) with a mean arterial patency of 70 % (follow-up mean, 4.9; range, 0-18 months). The 1-, 3-, and 6-month graft survival was 70, 40, and 35 %, respectively. Due to minimally invasive procedures, posttransplant extrahepatic pseudoaneurysms are no longer an exclusive complication of the transplant surgery itself. Endovascular management is effective to stabilize patients but has not improved historic postsurgical graft survival.« less

  1. Endovascular treatment of the subclavian artery aneurysm in high-risk patient - a single-center experience.

    PubMed

    Marjanović, Ivan; Tomić, Aleksandar; Marić, Nebojša; Pecarski, Danijela; Šarac, Momir; Paunović, Dragana; Rusović, Siniša

    2016-10-01

    We present our first experience with endovascular treatment of 6 subclavian artery aneurysms (SAA) occurring in five male and one female patient. All patients, in our studies, according to ASA classification were high risk for open repair of SAA. The etiology of the all aneurysms was atherosclerosis degeneration of the artery. Two aneurysms were of intrathoracic location, then the other were extrathoracic. Symptoms related to subclavian artery aneurysms were present in two patients, compression and chest pain in one, and hemorrhage shock in second, while the remaining patients were asymptomatic. We preferred the Viabhan endoprosthesis for endovascular repair in 5 cases. In one patient with ruptured of subclavian artery aneurysm who was high-risk for open repair we made combined endovascular procedure. First at all, we covered the origin of left subclavian artery with thoracic stent graft and after that we put two coils in proximal part of subclavian artery. There was no operative mortality, and the early patency rate was 100%. The follow-up period was from 3 months to 3 years. During this period, one patient died of heart failure and one patient required endovascular reoperation due to endoleak type I. Endovascular treatment is recommended for all patients with subclavian artery aneurysm whenever this is possible due to anatomical reasons especially in high-risk patient with intrathoracic localization of aneurysm, to prevent potential complications.

  2. Manufacturing conditioned roughness and wear of biomedical oxide ceramics for all-ceramic knee implants

    PubMed Central

    2013-01-01

    Background Ceramic materials are used in a growing proportion of hip joint prostheses due to their wear resistance and biocompatibility properties. However, ceramics have not been applied successfully in total knee joint endoprostheses to date. One reason for this is that with strict surface quality requirements, there are significant challenges with regard to machining. High-toughness bioceramics can only be machined by grinding and polishing processes. The aim of this study was to develop an automated process chain for the manufacturing of an all-ceramic knee implant. Methods A five-axis machining process was developed for all-ceramic implant components. These components were used in an investigation of the influence of surface conformity on wear behavior under simplified knee joint motion. Results The implant components showed considerably reduced wear compared to conventional material combinations. Contact area resulting from a variety of component surface shapes, with a variety of levels of surface conformity, greatly influenced wear rate. Conclusions It is possible to realize an all-ceramic knee endoprosthesis device, with a precise and affordable manufacturing process. The shape accuracy of the component surfaces, as specified by the design and achieved during the manufacturing process, has a substantial influence on the wear behavior of the prosthesis. This result, if corroborated by results with a greater sample size, is likely to influence the design parameters of such devices. PMID:23988155

  3. Manufacturing conditioned roughness and wear of biomedical oxide ceramics for all-ceramic knee implants.

    PubMed

    Turger, Anke; Köhler, Jens; Denkena, Berend; Correa, Tomas A; Becher, Christoph; Hurschler, Christof

    2013-08-29

    Ceramic materials are used in a growing proportion of hip joint prostheses due to their wear resistance and biocompatibility properties. However, ceramics have not been applied successfully in total knee joint endoprostheses to date. One reason for this is that with strict surface quality requirements, there are significant challenges with regard to machining. High-toughness bioceramics can only be machined by grinding and polishing processes. The aim of this study was to develop an automated process chain for the manufacturing of an all-ceramic knee implant. A five-axis machining process was developed for all-ceramic implant components. These components were used in an investigation of the influence of surface conformity on wear behavior under simplified knee joint motion. The implant components showed considerably reduced wear compared to conventional material combinations. Contact area resulting from a variety of component surface shapes, with a variety of levels of surface conformity, greatly influenced wear rate. It is possible to realize an all-ceramic knee endoprosthesis device, with a precise and affordable manufacturing process. The shape accuracy of the component surfaces, as specified by the design and achieved during the manufacturing process, has a substantial influence on the wear behavior of the prosthesis. This result, if corroborated by results with a greater sample size, is likely to influence the design parameters of such devices.

  4. Endovascular treatment of thoracic disease: patient selection and a proposal of a risk score.

    PubMed

    Rodrigues Alves, Claudia Maria; da Fonseca, José Honório Palma; de Souza, José Augusto Marcondes; Camargo Carvalho, Antonio Carlos; Buffolo, Enio

    2002-04-01

    Although selection criteria and subgroup analysis are still in the early developmental stages, endovascular treatment of aortic disease has become an alternative to surgery for many patients. From November 1996 to November 1999, 49 patients were treated with a self-expandable endoprosthesis at our institution. Most patients had acute aortic dissections. Thirteen of these patients did not follow the anatomic selection protocol. We retrospectively analyzed these patients to compare our numerical risk score (which includes clinical and anatomic criteria) between groups with or without success and between groups that followed the anatomic protocol (P) or did not follow the anatomic protocol (E [exception]). Success rates were similar in groups P and E, although mortality rates were higher in group E. Patients from group E had longer procedures and required multiple stents more frequently. The proposed risk score was able to differentiate between groups with or without success, as well as between groups P and E. In order to reduce mortality and morbidity rates, careful selection criteria must be followed when treating patients endovascularly. Although it is time-consuming, using objective criteria can help select patients for endovascular treatment. We propose that patients with a risk score higher than 11 should only undergo percutaneous treatment when they have an unacceptably high surgical risk, and even so only after a detailed discussion of the risks.

  5. Neutrophil-derived MRP-14 is up-regulated in infectious osteomyelitis and stimulates osteoclast generation.

    PubMed

    Dapunt, Ulrike; Giese, Thomas; Maurer, Susanne; Stegmaier, Sabine; Prior, Birgit; Hänsch, G Maria; Gaida, Matthias M

    2015-10-01

    Bone infections of patients with joint replacement by endoprosthesis (so called "periprosthetic joint infection") pose a severe problem in the field of orthopedic surgery. The diagnosis is often difficult, and treatment is, in most cases, complicated and prolonged. Patients often require an implant exchange surgery, as the persistent infection and the accompanying inflammation lead to tissue damage with bone degradation and consequently, to a loosening of the implant. To gain insight into the local inflammatory process, expression of the proinflammatory cytokine MRP-14, a major content of neutrophils, and its link to subsequent bone degradation was evaluated. We found MRP-14 prominently expressed in the affected tissue of patients with implant-associated infection, in close association with the chemokine CXCL8 and a dense infiltrate of neutrophils and macrophages. In addition, the number of MRP-14-positive cells correlated with the presence of bone-resorbing osteoclasts. MRP-14 plasma concentrations were significantly higher in patients with implant-associated infection compared with patients with sterile inflammation or healthy individuals, advocating MRP-14 as a novel diagnostic marker. A further biologic activity of MRP-14 was detected: rMRP-14 directly induced the differentiation of monocytes to osteoclasts, thus linking the inflammatory response in implant infections with osteoclast generation, bone degradation, and implant loosening. © Society for Leukocyte Biology.

  6. Combined liver resection and reconstruction of the supra-renal vena cava: the Paul Brousse experience.

    PubMed

    Azoulay, Daniel; Andreani, Paola; Maggi, Umberto; Salloum, Chadi; Perdigao, Fabiano; Sebagh, Mylène; Lemoine, Antoinette; Adam, René; Castaing, Denis

    2006-07-01

    Liver tumors with inferior vena cava (IVC) involvement may require combined resection of the liver and IVC. This approach, with its high surgical risks and poor long-term prognosis, was precluded until the development of neoadjuvant chemotherapy, portal vein embolization, reinforced vascular prostheses, and technical advances in liver transplantation. We reviewed 22 cases of hepatectomy with retrohepatic IVC resection and reconstruction. The patients had a median age of 51.5 years (range, 32.8-75.3 years). Indications for resection were: liver metastases (n = 9), cholangiocarcinoma (n = 8), hepatocellular carcinoma (n = 2), other cancers (n = 3). The liver resections carried out included 18 first, 3 second, and one third hepatectomy. Segment 1 (caudate lobe) was included in the specimen in 19 cases (86%). Resection concerned 1 to 6 liver segments (median = 5.0). Vascular control was achieved by vascular exclusion of the liver preserving the caval flow (n = 1), standard vascular exclusion of the liver (n = 12), in situ cold perfusion of the liver (n = 9). Ex situ surgery was not necessary in any case. Venovenous bypass was used in 12 cases. The IVC was reconstructed with a ringed Gore-Tex tube graft (n = 10), primarily (n = 8), or by caval plasty (n = 4). A main hepatic vein was reimplanted in 6 cases: into the native IVC (n = 4) or into a Gore-Tex tube graft (n = 2). One patient died (4.5%) due to catheter infection, 7 days after in situ cold perfusion with replacement of the vena cava. Eight patients (36%) had no complications and 14 patients (64%) had 23 complications. In all but 1 case, the complications were transient and successfully controlled. The patients stayed in intensive care for 3.3 +/- 2.0 days and in the hospital for 17.7 +/- 7.8 days. All vascular reconstructions were patent at last follow-up. With median follow-up of 19 months, 10 patients died of tumor recurrence and eleven were alive with (n = 5) or without (n = 6) disease. Actuarial 1-, 3-, and

  7. Patent Foramen Ovale Closure or Antiplatelet Therapy for Cryptogenic Stroke.

    PubMed

    Søndergaard, Lars; Kasner, Scott E; Rhodes, John F; Andersen, Grethe; Iversen, Helle K; Nielsen-Kudsk, Jens E; Settergren, Magnus; Sjöstrand, Christina; Roine, Risto O; Hildick-Smith, David; Spence, J David; Thomassen, Lars

    2017-09-14

    patients (6.6%) after PFO closure. Among patients with a PFO who had had a cryptogenic stroke, the risk of subsequent ischemic stroke was lower among those assigned to PFO closure combined with antiplatelet therapy than among those assigned to antiplatelet therapy alone; however, PFO closure was associated with higher rates of device complications and atrial fibrillation. (Funded by W.L. Gore and Associates; Gore REDUCE ClinicalTrials.gov number, NCT00738894 .).

  8. Influence of material coupling and assembly condition on the magnitude of micromotion at the stem-neck interface of a modular hip endoprosthesis.

    PubMed

    Jauch, S Y; Huber, G; Hoenig, E; Baxmann, M; Grupp, T M; Morlock, M M

    2011-06-03

    Hip prostheses with a modular neck exhibit, compared to monobloc prostheses, an additional interface which bears the risk of fretting as well as corrosion. Failures at the neck adapter of modular prostheses have been observed for a number of different designs. It has been speculated that micromotions at the stem-neck interface were responsible for these implant failures. The purpose of this study was to investigate the influence of material combinations and assembly conditions on the magnitude of micromotions at the stem-neck interface during cyclic loading. Modular (n = 24) and monobloc (n = 3) hip prostheses of a similar design (Metha, Aesculap AG, Tuttlingen, Germany) were subjected to mechanical testing according to ISO 7206-4 (F(min) = 230N, F(max) = 2300N, f = 1Hz, n = 10,000 cycles). The neck adapters (Ti-6Al-4V or Co-Cr29-Mo alloy) were assembled with a clean or contaminated interface. The micromotion between stem and neck adapter was calculated at five reference points based on the measurements of the three eddy current sensors. The largest micromotions were observed at the lateral edge of the stem-neck taper connection, which is in accordance with the crack location of clinically failed prostheses. Titanium neck adapters showed significantly larger micromotions than cobalt-chromium neck adapters (p = 0.005). Contaminated interfaces also exhibited significantly larger micromotions (p < 0.001). Since excessive micromotions at the stem-neck interface might be involved in the process of implant failure, special care should be taken to clean the interface prior to assembly and titanium neck adapters with titanium stems should generally be used with caution. Copyright © 2011 Elsevier Ltd. All rights reserved.

  9. Reconstruction of the proximal humerus with a composite of extracorporeally irradiated bone and endoprosthesis following excision of high grade primary bone sarcomas.

    PubMed

    Moran, Matthew; Stalley, Paul D

    2009-10-01

    Functional reconstruction of the shoulder joint following excision of a malignant proximal humeral tumour is a difficult proposition. Eleven patients with primary osteosarcoma or Ewing's sarcoma underwent reconstruction with a composite of extra-corporeally irradiated autograft with the addition of a long stemmed hemiarthroplasty. At a mean follow-up of 5.8 years two patients had died from disseminated disease and one patient had undergone amputation for local recurrence. The eight patients with a surviving limb were examined clinically and radiographically. The mean Toronto Extremity Salvage Score was 74 and Musculo-Skeletal Tumour Society score 66. Rotation was well preserved but abduction (mean 32 degrees ) and flexion (40 degrees ) were poor. There was a high rate of secondary surgery, with five out of eleven patients requiring re-operation for complications of reconstruction surgery. Radiographic estimate of graft remaining at follow up was 71%. There were no infections, revisions or radiographic failures. Whilst the reconstructions were durable in the medium term, the functional outcome was no better than with other reported reconstructive methods. The composite technique was especially useful in subtotal humeral resections, allowing preservation of the elbow joint even with very distal osteotomy. Bone stock is restored, which may be useful for future revision surgery in this young group of patients.

  10. Hazards protection for space suits and spacecraft

    NASA Technical Reports Server (NTRS)

    Kosmo, Joseph J. (Inventor); Dawn, Frederic S. (Inventor)

    1990-01-01

    A flexible multi-layered covering article for protection against the hazards of exposure to the environment of outer space is disclosed. The covering includes an outer layer section comprising an outermost lamina of woven expanded tetrafluoroethylene yarns (Gore Tex) for protecting against abrasion and tearing, an underlying weave of meta-aramid yarns (Nomex) and para-aramid yarns (Kevlar) for particle impart protection, and electrostatic charge dissipation and control system incorporated therein, and a chemical contaminants control barrier applied as a coating. A middle section includes a succession of thermal insulating layers of polymeric thermoplastic or thermoforming material, each of which is coated with a metal deposit of high infra-red emissivity and low solar radiation absorption characteristics and separated from adjacent insulating layers by a low thermal conductance material. The covering further includes a radiation attenuating layer of a tungsten-loaded polymeric elastomer binder for protecting against bremsstrahlung radiation and an inner layer of rip-stop polyester material for abrasion protection. A chloroprene coating may be supplied the polyester-material for added micrometeroid protection. Securing means of low heat conductance material secures the multi-layers together as a laminar composite.

  11. Comparison of Envisat ASAR and Submarine Sea Ice Thickness Statistics

    NASA Astrophysics Data System (ADS)

    Hughes, Nicolas E.; Rodrigues, Joao; Wadhams, Peter

    2010-12-01

    In April 2004 and March 2007 the Royal Navy sent the submarine HMS Tireless on missions into the Arctic Ocean. On both occasions the submarine traversed the area of remaining multi-year sea ice at latitude 85°N north of Greenland acquiring ice draft measurements using upward-looking sonar. The area is outside of the "Gore Box" used for the release of U.S. Submarine data and was beyond the latitude range of the radar altimeter satellites available at that time. This paper compares ice draft statistics with contemporary data from Envisat ASAR to evaluate the level of correlation between SAR backscatter and sea ice thickness. The decline in sea ice volume over the past decade has predominantly been caused by the loss of old multi-year ice due to increased outflow through Fram Strait. Although Tireless found little decrease in the overall ice thickness between 2004 and 2007, the ice rheology was significantly changed with greatly increased quantities of first- and second-year ice in 2007 than had been encountered in 2004. These are evident in changes to the ice draft probability density functions (PDFs) and the ice appearance as seen by the SAR, and presented here.

  12. Mass loss of shuttle space suit orthofabric under simulated ionospheric atomic oxygen bombardment

    NASA Technical Reports Server (NTRS)

    Miller, W. L.

    1985-01-01

    Many polymeric materials used for thermal protection and insulation on spacecraft degrade significantly under prolonged bombardment by ionospheric atomic oxygen. The covering fabric of the multilayered shuttle space suit is composed of a loose weave of GORE-TEX fibers, Nomex and Kevlar-29, which are all polymeric materials. The complete evaluation of suit fabric degradation from ionospheric atomic oxygen is of importance in reevaluating suit lifetime and inspection procedures. The mass loss and visible physical changes of each test sample was determined. Kapton control samples and data from previous asher and flight tests were used to scale the results to reflect ionospheric conditions at about 220 km altitude. It is predicted that the orthofabric loses mass in the ionosphere at a rate of about 66% of the original orthofabric mass/yr. The outer layer of the two-layer orthofabric test samples shows few easily visible signs of degradation, even when observed at 440X. It is concluded that the orthofabric could suffer significant loss of performance after much less than a year of total exposure time, while the degradation might be undetectable in post flight visual examinations of space suits.

  13. Quantification of hepatic flow distribution using particle tracking for patient specific virtual Fontan surgery

    NASA Astrophysics Data System (ADS)

    Yang, Weiguang; Vignon-Clementel, Irene; Troianowski, Guillaume; Shadden, Shawn; Mohhan Reddy, V.; Feinstein, Jeffrey; Marsden, Alison

    2010-11-01

    The Fontan surgery is the third and final stage in a palliative series to treat children with single ventricle heart defects. In the extracardiac Fontan procedure, the inferior vena cava (IVC) is connected to the pulmonary arteries via a tube-shaped Gore-tex graft. Clinical observations have shown that the absence of a hepatic factor, carried in the IVC flow, can cause pulmonary arteriovenous malformations. Although it is clear that hepatic flow distribution is an important determinant of Fontan performance, few studies have quantified its relation to Fontan design. In this study, we virtually implanted three types of grafts (T-junction, offset and Y-graft) into 5 patient specific models of the Glenn (stage 2) anatomy. We then performed 3D time-dependent simulations and systematically compared the IVC flow distribution, energy loss, and pressure levels in different surgical designs. A robustness test is performed to evaluate the sensitivity of hepatic distribution to pulmonary flow split. Results show that the Y-graft design effectively improves the IVC flow distribution, compared to traditional designs and that surgical designs could be customized on a patient-by-patient basis.

  14. The Hammer Award is presented to KSC and 45th Space Wing.

    NASA Technical Reports Server (NTRS)

    1999-01-01

    At a special presentation of the Hammer Award in the IMAX 2 Theater in the Kennedy Space Center Visitor Complex, former Apollo astronauts Neil Armstrong (left) and Edwin 'Buzz' Aldrin (second from right) applauded the recipients, Kennedy Space Center and the 45th Space Wing. The Hammer Award is Vice President Al Gore's special recognition of teams of federal employees who have made significant contributions in support of the principles of the National Partnership for Reinventing Government. This Hammer Award acknowledges the accomplishments of a joint NASA and Air Force team that established the Joint Base Operations and Support Contract (J-BOSC) Source Evaluation Board (SEB). Ed Gormel and Chris Fairey, co-chairs of the SEB, accepted the awards for the SEB. The team developed and implemented the acquisition strategy for establishing a single set of base operations and support service requirements for KSC, Cape Canaveral Air Station and Patrick Air Force Base. Armstrong and Aldrin were at KSC to attend a banquet and other activities for the 30th anniversary of the Apollo 11 mission, which landed the first man on the moon.

  15. KSC-99pp0839

    NASA Image and Video Library

    1999-07-16

    At a special presentation of the Hammer Award in the IMAX 2 Theater in the Kennedy Space Center Visitor Complex, former Apollo astronauts Neil Armstrong (left) and Edwin "Buzz" Aldrin (second from right) applauded the recipients, Kennedy Space Center and the 45th Space Wing. The Hammer Award is Vice President Al Gore's special recognition of teams of federal employees who have made significant contributions in support of the principles of the National Partnership for Reinventing Government. This Hammer Award acknowledges the accomplishments of a joint NASA and Air Force team that established the Joint Base Operations and Support Contract (J-BOSC) Source Evaluation Board (SEB). Ed Gormel and Chris Fairey, co-chairs of the SEB, accepted the awards for the SEB. The team developed and implemented the acquisition strategy for establishing a single set of base operations and support service requirements for KSC, Cape Canaveral Air Station and Patrick Air Force Base. Armstrong and Aldrin were at KSC to attend a banquet and other activities for the 30th anniversary of the Apollo 11 mission, which landed the first man on the moon

  16. Mechanical properties of ANTRIX balloon film and fabrication of single cap large volume balloons

    NASA Astrophysics Data System (ADS)

    Suneel Kumar, B.; Sreenivasan, S.; Subba Rao, J. V.; Manchanda, R. K.

    2008-11-01

    The zero pressure plastic balloons used for high altitude studies are generally made from polyethylene material. Tensile properties of the thin film polymer are the key parameters for material selection due to extremely low temperature of -90 °C encountered by the balloons in the tropopause region during the ascent at equatorial latitudes. The physical and structural properties of the material determine the uniformity of the stress distribution over the entire shell. Load stresses from the suspended load propagate via load tapes heat sealed along with the gore seals as per the balloon design. A balance between this heat seal strength and the film strength is a desirable property of the basic resin in terms of the bubble strength, gauge uniformity, and long-term storage properties. In addition, the design of the top shell of the balloon and its stress distribution play an important role since only a fraction of the balloon is deployed during the filling operation and the ascent. In this paper we describe the mechanical properties of the 'ANTRIX' film developed by us and the optimized design of single cap balloons, which have been successfully used in our experiments over the past 5 years.

  17. Optimization of an idealized Y-Shaped Extracardiac Fontan Baffle

    NASA Astrophysics Data System (ADS)

    Yang, Weiguang; Feinstein, Jeffrey; Mohan Reddy, V.; Marsden, Alison

    2008-11-01

    Research has showed that vascular geometries can significantly impact hemodynamic performance, particularly in pediatric cardiology, where anatomy varies from one patient to another. In this study we optimize a newly proposed design for the Fontan procedure, a surgery used to treat single ventricle heart patients. The current Fontan procedure connects the inferior vena cava (IVC) to the pulmonary arteries (PA's) via a straight Gore-Tex tube, forming a T-shaped junction. In the Y-graft design, the IVC is connected to the left and right PAs by two branches. Initial studies on the Y-graft design showed an increase in efficiency and improvement in flow distribution compared to traditional designs in a single patient-specific model. We now optimize an idealized Y-graft model to refine the design prior to patient testing. A derivate-free optimization algorithm using Kriging surrogate functions and mesh adaptive direct search is coupled to a 3-D finite element Navier-Stokes solver. We will present optimization results for rest and exercise conditions and examine the influence of energy efficiency, wall shear stress, pulsatile flow, and flow distribution on the optimal design.

  18. Simulating clefts in pumpkin balloons

    NASA Astrophysics Data System (ADS)

    Baginski, Frank; Brakke, Kenneth

    2010-02-01

    The geometry of a large axisymmetric balloon with positive differential pressure, such as a sphere, leads to very high film stresses. These stresses can be significantly reduced by using a tendon re-enforced lobed pumpkin-like shape. A number of schemes have been proposed to achieve a cyclically symmetric pumpkin shape, including the constant bulge angle (CBA) design, the constant bulge radius (CBR) design, CBA/CBR hybrids, and NASA’s recent constant stress (CS) design. Utilizing a hybrid CBA/CBR pumpkin design, Flight 555-NT in June 2006 formed an S-cleft and was unable to fully deploy. In order to better understand the S-cleft phenomenon, a series of inflation tests involving four 27-m diameter 200-gore pumpkin balloons were conducted in 2007. One of the test vehicles was a 1/3-scale mockup of the Flight 555-NT balloon. Using an inflation procedure intended to mimic ascent, the 1/3-scale mockup developed an S-cleft feature strikingly similar to the one observed in Flight 555-NT. Our analysis of the 1/3-scale mockup found it to be unstable. We compute asymmetric equilibrium configurations of this balloon, including shapes with an S-cleft feature.

  19. Identifying Crucial Issues in Climate Science

    NASA Astrophysics Data System (ADS)

    Ikeda, Motoyoshi; Greve, Ralf; Hara, Toshika; Watanabe, Yutaka W.; Ohmura, Atsumu; Ito, Akihiko; Kawamiya, Michio

    2009-01-01

    Drastic Change in the Earth System During Global Warming; Sapporo, Japan, 24 June 2008; The Nobel Peace Prize awarded to the Intergovernmental Panel on Climate Change (IPCC) and former U.S. vice president Al Gore indicates that global warming is recognized as a real phenomenon critical to human beings. However, humanity's knowledge concerning global warming is based on an uncertainty larger than 50% in the warming rate during the past century. Therefore, scientific clarification is needed to understand important mechanisms that potentially produce positive feedbacks in the Earth system-such mechanisms must be better understood before scientists can develop more reliable predictions. To plan for the future, a symposium was organized at Japan's Hokkaido University in association with the G8 Summit, where the most recent updates on the five urgent issues in climate science were discussed. These issues, considered to be crucial as severe impacts on human society continue to rise, included (1) causes and magnitude of sea level rise; (2) decay of glaciers and the Greenland and Antarctic ice sheets; (3) disappearance of the summer Arctic sea ice; (4) carbon uptake or emission by the terrestrial ecosystem; and (5) marine ecosystem change resulting in carbon emissions.

  20. Systematic review of self-expanding stents in the management of benign colorectal obstruction.

    PubMed

    Currie, A; Christmas, C; Aldean, H; Mobasheri, M; Bloom, I T M

    2014-04-01

    Colorectal obstruction due to benign disease is likely to become more prevalent. Self-expanding stents have been shown to be effective in reducing morbidity and allowing one-stage resection or improved palliation in colorectal cancer. This review assessed the use of self-expanding stents in benign colorectal obstruction. A systematic review was performed using PubMed, Embase and the Cochrane Library. Keywords included: 'benign disease' 'colorectal obstruction', 'stent', 'endoprosthesis' and 'prosthesis' Original articles from all relevant listings were sourced. These were hand searched for further articles of relevance. The main outcome measures assessed were technical and clinical success, perforation, reobstruction and stoma avoidance in the bridge to surgery population. The search strategy identified 130 articles; the 21 included studies yielded a pooled analysis of 122 patients. Diverticulitis was the predominant aetiology (66/122, 54%). Technical success was achieved in 115/122 (94%) and clinical success in 108/120 (87%) patients. Overall, the perforation rate was 12% (15/122) and the reobstruction rate was 14% (17/122). A stoma was avoided in 48% (23/48) of bridge to surgery patients. Perforation and stoma avoidance in the bridge to surgery group were worse with an aetiology of diverticulitis. Complication rates in stenting for benign colorectal obstruction are higher than for malignant obstruction. On the basis of limited published evidence, stenting cannot be recommended for benign colorectal obstruction. Colorectal Disease © 2013 The Association of Coloproctology of Great Britain and Ireland.

  1. Bilateral hypogastric artery occlusion in endovascular repair of abdominal aortic aneurysms and its clinical significance.

    PubMed

    Zander, Tobias; Baldi, Sebastian; Rabellino, Martin; Rostagno, Roman; Isaza, Baltasar; Llorens, Rafael; Carreira, Jose M; Maynar, Manuel

    2007-12-01

    Endovascular treatment of aortoiliac aneurysms near or involving the hypogastric artery (HGA) requires HGA occlusion before endografting to avoid retrograde filling of the aneurysm. The purpose of this study is to evaluate clinical outcomes of bilateral HGA occlusion and determine if benefits gained by endovascular aneurysm repair (EVAR) outweigh the morbidity associated with the procedure. Between 1999 and 2004, 128 patients with abdominal aortic aneurysm (AAA) were treated with bifurcated endograft placement. Bilateral coverage or embolization of HGAs was performed in 14 patients (10.9%). Embolization was achieved by deployment of coils and coverage was accomplished by extending the endoprosthesis into the external iliac artery. Clinical follow-up and computed tomographic angiography were performed at 1, 3, 6, 9, and 12 months and annually thereafter to detect potential aneurysm growth and endoleaks. During follow-up (range, 1-72 months), buttock claudication was noted in four patients (28.6%), including unilateral claudication in two and bilateral claudication in two. One patient experienced claudication longer than 12 months, which resolved within 18 months. De novo erectile dysfunction was seen in one patient, and pelvic ischemia was not found in any patient. There was no evidence of endoleak, aneurysm enlargement, or death associated with HGA occlusion. In our series, complications of bilateral HGA occlusion before EVAR were moderate and resolved over time. The benefits gained from EVAR outweigh the clinical problems caused by bilateral HGA occlusion, as there are no technical complications added to the EVAR procedure.

  2. Variability of medial and posterior offset in patients with fourth-generation stemmed shoulder arthroplasty.

    PubMed

    Irlenbusch, Ulrich; Berth, Alexander; Blatter, Georges; Zenz, Peter

    2012-03-01

    Most anthropometric data on the proximal humerus has been obtained from deceased healthy individuals with no deformities. Endoprostheses are implanted for primary and secondary osteoarthritis, rheumatoid arthritis,humeral-head necrosis, fracture sequelae and other humeral-head deformities. This indicates that pathologicoanatomical variability may be greater than previously assumed. We therefore investigated a group of patients with typical shoulder replacement diagnoses, including posttraumatic and rheumatic deformities. One hundred and twenty-two patients with a double eccentrically adjustable shaft endoprosthesis served as a specific dimension gauge to determine in vivo the individual humeral-head rotation centres from the position of the adjustable prosthesis taper and the eccentric head. All prosthesis heads were positioned eccentrically.The entire adjustment range of the prosthesis of 12 mm medial/lateral and 6 mm dorsal/ventral was required. Mean values for effective offset were 5.84 mm mediolaterally[standard deviation (SD) 1.95, minimum +2, maximum +11]and 1.71 mm anteroposteriorly (SD 1.71, minimum −3,maximum 3 mm), averaging 5.16 mm (SD 1.76, minimum +2,maximum + 10). The posterior offset averaged 1.85 mm(SD 1.85, minimum −1, maximum + 6 mm). In summary, variability of the combined medial and dorsal offset of the humeral-head rotational centre determined in patients with typical underlying diagnoses in shoulder replacement was not greater than that recorded in the literature for healthy deceased patients.The range of deviation is substantial and shows the need for an adjustable prosthetic system.

  3. Socio-Occupational and Physical Outcomes More than 20 Years after Diagnosis for Osteosarcoma in Children and Adolescents: Limb Salvage versus Amputation

    PubMed Central

    Ottaviani, Giulia; Robert, Rhonda S.; Huh, Winston W.; Palla, Shana; Jaffe, Norman

    2013-01-01

    BACKGROUND To date, there has been relatively little research on very-long-term survivors of childhood and adolescent osteosarcoma. We sought to compare the very-long-term outcomes of osteosarcoma patients treated with either limb salvage procedures or amputation. MATERIALS AND METHODS Thirty-eight long-term osteosarcoma patients surviving 20 or more years from diagnosis were divided into two groups according to whether they underwent amputation or limb salvage. Participants were asked to complete a questionnaire about education, employment, annual income, marital status, health insurance, lifestyle, siblings, and all current and past health issues. RESULTS Education, employment, marital status, and health insurance did not differ significantly between the two groups of survivors, and they described themselves as similar to their siblings. Eight percent of survivors underwent secondary amputation due to complications with an endoprosthesis. The cumulative incidence of second primary neoplasms was 13%, and this was significantly higher in females and in survivors who underwent radiotherapy and had genetic predisposition. The second primary malignancies were breast cancer (ductal invasive carcinoma, ductal in situ carcinoma, leiomyosarcoma), mediastinal leiomyosarcoma, squamocellular carcinoma of the oral cavity and of the uterine cervix. Amputees required more assistive walking support than survivors who received limb salvage treatments (χ2 test, p <0.05). CONCLUSIONS Despite the many challenges that osteosarcoma survivors face, patients who survived over 20 years after their initial diagnosis reported having overall adjusted well to their physical limitations and were productive individuals. PMID:23907996

  4. Efficacy of transoral intraluminal Wallstents for tracheal stenosis or tracheomalacia.

    PubMed

    Casiano, R R; Numa, W A; Nurko, Y J

    2000-10-01

    The efficacy and safety of intraluminal Wallstent Endoprosthesis (Boston Scientific/ Medi-Tech, Quincy, MA) placement to restore airway patency in patients with tracheal stenosis or tracheomalacia are unknown. Retrospective review in setting of tertiary, referral, and academic center. A retrospective review of 13 consecutive patients over a 2-year period who underwent transoral resection of tracheal stenosis and immediate transoral Wallstent placement. One patient had tracheomalacia. All of the patients were considered at high risk for transcervical surgery or had failed prior traditional open procedures. The average patient age was 54.2 years, with nine male and four female patients. All had Cotton/Myer stenoses (grades II to IV) with moderate to severe degrees of inspiratory stridor. Four patients were tracheotomy dependent. The length of stenosis varied from 1 to 4 cm. One patient had a 10-cm segment of tracheomalacia. At the time of writing, none of the patients has had a problem with significant migration or extrusion and most of the patients have incorporated the stent well without any short-term obstructive granulation tissue. After a mean follow-up of 15 months (range, 4-24 mo). 10 of the 12 patients with stenosis (83%) have remained free of any inspiratory noise during breathing. The one patient with tracheomalacia also has remained free of symptoms. Transoral Wallstents appear to be safe and may be a reasonable alternative in the restoration of airway patency in select patients with tracheal stenosis or tracheomalacia.

  5. Intraluminal low-dose-rate 192Ir brachytherapy combined with external beam radiotherapy and biliary stenting for unresectable extrahepatic bile duct carcinoma.

    PubMed

    Takamura, Akio; Saito, Hiroya; Kamada, Tadashi; Hiramatsu, Kazuhide; Takeuchi, Shuhei; Hasegawa, Masakazu; Miyamoto, Noriyuki

    2003-12-01

    To evaluate the results of combined-modality therapy, including external beam radiotherapy, intraluminal (192)Ir, and biliary stenting for extrahepatic bile duct carcinoma. Between 1988 and 1998, 93 patients with unresectable extrahepatic bile duct carcinoma underwent definitive radiotherapy. The dose of external beam radiotherapy was 50 Gy in 25 fractions. Low-dose-rate (192)Ir was delivered at a dose of 27-50 Gy (mean 39.2) at 0.5 cm from the source. An expandable metallic endoprosthesis was used to establish an internal bile passage. The median survival was 12 months, with a 1-, 3-, and 5-year actuarial survival rate of 50%, 10%, and 4%, respectively. Tumor length, hepatic invasion, and distant metastasis significantly affected survival. Ninety-six percent of patients could successfully remove external drainage catheters. The actuarial biliary patency rate for these patients at 1, 3, and 5 years was 52%, 29%, and 18%, respectively. Tumor length, tumor diameter and T stage were significantly associated with the patency rate. Mild-to-severe gastroduodenal complications were observed in 32 patients and were significantly associated with the active length of (192)Ir and linear source activity. Eight patients had treatment-related biliary fistula. Our combined-modality therapy provided reasonable local control and improved the quality of life of patients with extrahepatic bile duct carcinoma. Because none of the treatment characteristics had any impact on survival or biliary patency, lower dose levels and/or a localized target volume are recommended to minimize morbidity.

  6. Endovascular repair of abdominal aortic aneurysms: vascular anatomy, device selection, procedure, and procedure-specific complications.

    PubMed

    Bryce, Yolanda; Rogoff, Philip; Romanelli, Donald; Reichle, Ralph

    2015-01-01

    Abdominal aortic aneurysm (AAA) is abnormal dilatation of the aorta, carrying a substantial risk of rupture and thereby marked risk of death. Open repair of AAA involves lengthy surgery time, anesthesia, and substantial recovery time. Endovascular aneurysm repair (EVAR) provides a safer option for patients with advanced age and pulmonary, cardiac, and renal dysfunction. Successful endovascular repair of AAA depends on correct selection of patients (on the basis of their vascular anatomy), choice of the correct endoprosthesis, and familiarity with the technique and procedure-specific complications. The type of aneurysm is defined by its location with respect to the renal arteries, whether it is a true or false aneurysm, and whether the common iliac arteries are involved. Vascular anatomy can be divided more technically into aortic neck, aortic aneurysm, pelvic perfusion, and iliac morphology, with grades of difficulty with respect to EVAR, aortic neck morphology being the most common factor to affect EVAR appropriateness. When choosing among the devices available on the market, one must consider the patient's vascular anatomy and choose between devices that provide suprarenal fixation versus those that provide infrarenal fixation. A successful technique can be divided into preprocedural imaging, ancillary procedures before AAA stent-graft placement, the procedure itself, postprocedural medical therapy, and postprocedural imaging surveillance. Imaging surveillance is important in assessing complications such as limb thrombosis, endoleaks, graft migration, enlargement of the aneurysm sac, and rupture. Last, one must consider the issue of radiation safety with regard to EVAR. (©)RSNA, 2015.

  7. Funding health technologies in decentralized systems: A comparison between Italy and Spain.

    PubMed

    Cappellaro, Giulia; Fattore, Giovanni; Torbica, Aleksandra

    2009-10-01

    Although cost-containment policies in Europe are focusing increasingly on medical devices, the impact of these policies has yet to be fully investigated, particularly in cross-country settings. This paper analyses coverage, procurement, and reimbursement of three inpatient medical devices (coronary stent, knee endoprosthesis and implantable cardioverter defibrillator) in the Italian and Spanish healthcare systems. The research was carried out by reviewing published and grey literature, as well as national and regional legislation; in addition, 19 experts from hospitals and the industry were interviewed. In both countries, there has been a shift in political power from the national to the regional level. At the same time, the content of public coverage has become more explicit. A major issue in both systems is reimbursement, i.e. the rules about funding the delivery of services included in the benefit baskets. The differences in procurement and funding mechanisms create different incentives that may have an impact on the uptake and diffusion of technologies. These mechanisms, however, can only partially explain organizational and professional behaviour, as the use of technologies in both countries is mainly left to professionals who are exposed to a variety of incentives. There is limited direct and indirect guidance of national and regional authorities over the use of technologies in both countries. It is likely that the difficult search for a balance between introducing innovations, containing costs and assuring equity will require stronger regulatory action in the next future.

  8. Modification of Ti6Al4V surface by diazonium compounds.

    PubMed

    Sandomierski, Mariusz; Buchwald, Tomasz; Strzemiecka, Beata; Voelkel, Adam

    2018-02-15

    Ti6Al4V alloy is the most commonly used in orthopedic industry as an endoprosthesis. Ti6Al4V exhibits good mechanical properties, except the abrasion resistance. Surface modification of Ti6Al4V in order to obtain organic layer, and then the attachment of the polymer, can allow for overcoming this problem. The aim of the work was the modification of Ti6Al4V surface by diazonium compounds: salt or cation generated in situ and examine the influence of the reducing agent - ascorbic acid, and the temperature of reaction on modification process. Moreover, the simulated body fluid was used for the assessment of the organic layer stability on Ti6Al4V surface. The evaluation of the modification was carried out using the following methods: Raman microspectroscopy, scanning electron microscopy and energy-dispersive X-ray spectroscopy. Higher temperature of modification by 4-hydroxymethylbenzenediazonium cation, provides the largest amount of organic layer on the Ti6Al4V alloy. In the case of the Ti6Al4V modified by Variamine Blue B salt, the amount of organic layer is not dependent on the reaction condition. Moreover, the ascorbic acid and the presence of TiO 2 does not effect on the modification. The modified surface is completely coated with the organic layer which is stable in simulated body fluid. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Carbon-Fibre-Reinforced SiC Composite (C/SiSiC) as an Alternative Material for Endoprosthesis: Fabrication, Mechanical and In-Vitro Biological Properties

    PubMed Central

    Reichert, Aline; Gadow, Rainer; Mayr, Hermann O.; Suedkamp, Norbert P.; Weichand, Partick; Bernstein, Anke

    2018-01-01

    Particle-induced periprosthetic osteolysis and subsequent aseptic implant loosening are a major cause of compromising the long-term results of total joint replacements. To date, no implant has been able to mirror radically the tribological factors (friction/lubrication/wear) of in vivo tribological pairings. Carbon-Fibre Reinforced SiC-Composites (C/SiSiC), a material primarily developed for brake technology, has the opportunity to fulfil this requirement. Until now, the material itself has not been used in medicine. The aim of this investigation was to test the suitability of C/SiSiC ceramics as a new material for bearing couples in endoprosthetics. After the preparation of the composites flexural strength was determined as well as the Young’s-modulus and the coefficient of friction. To investigate in vitro biological properties, MG 63 and primary human osteoblasts were cultured on C/SiSiC composites. To review the proliferation, the cytotoxicity standardized tests were used. The cell morphology was observed by light microscopy, ESEM, confocal and 3D-laserscanning microscopy. C/SiSiC possesses a high resistance to wear. Cells exhibited no significant alterations in morphology. Vitality was not impaired by contact with the ceramic composite. There was no higher cytotoxicity to observe. Regarding these results, C/SiSiC ceramics seem to be biologically and mechanically appropriate for orthopaedic applications. PMID:29470416

  10. "Busting with Blood and Gore and Full of Passion": The Impact of an Oral Retelling of the "Iliad" in the Primary Classroom

    ERIC Educational Resources Information Center

    Reedy, David; Lister, Bob

    2007-01-01

    This paper describes the impact of an oral retelling of Homer's "Iliad" on pupils' learning in Key Stage 2 classrooms (children aged 9-11) in schools in East London. We argue that the oral nature of the retelling and responses promoted high levels of engagement and inclusion, leading to enhanced understanding by the pupils. The use of a…

  11. Transient cracks and triple junctions induced by Cocos-Nazca propagating rift

    NASA Astrophysics Data System (ADS)

    Schouten, H.; Smith, D. K.; Zhu, W.; Montesi, L. G.; Mitchell, G. A.; Cann, J. R.

    2009-12-01

    The Galapagos triple junction is a ridge-ridge-ridge triple junction where the Cocos, Nazca, and Pacific plates meet around the Galapagos microplate (GMP). On the Cocos plate, north of the large gore that marks the propagating Cocos-Nazca (C-N) Rift, a 250-km-long and 50-km-wide band of NW-SE-trending cracks crosscuts the N-S-trending abyssal hills of the East Pacific Rise (EPR). These appear as a succession of minor rifts, accommodating some NE-SW extension of EPR-generated seafloor. The rifts successively intersected the EPR in triple junctions at distances of 50-100 km north of the tip of the C-N Rift. We proposed a simple crack interaction model to explain the location of the transient rifts and their junction with the EPR. The model predicts that crack locations are controlled by the stress perturbation along the EPR, induced by the dominant C-N Rift, and scaled by the distance of its tip to the EPR (Schouten et al., 2008). The model also predicts that tensile stresses are symmetric about the C-N Rift and thus, similar cracks should have occurred south of the C-N Rift prior to formation of the GMP about 1 Ma. There were no data at the time to test this prediction. In early 2009 (AT 15-41), we mapped an area on the Nazca plate south of the C-N rift out to 4 Ma. The new bathymetric data confirm the existence of a distinctive pattern of cracks south of the southern C-N gore that mirrors the pattern on the Cocos plate until about 1 Ma, and lends support to the crack interaction model. The envelope of the symmetric cracking pattern indicates that the distance between the C-N Rift tip and the EPR varied between 40 and 65 km during this time (1-4 Ma). The breakdown of the symmetry at 1 Ma accurately dates the onset of a southern plate boundary of the GMP, now Dietz Deep Rift. At present, the southern rift boundary of the GMP joins the EPR with a steep-sided, 80 km long ridge. This ridge releases the stress perturbation otherwise induced along the EPR by elastic

  12. Late Cenozoic Colorado River Incision and Implications for Neogene Uplift of the Colorado Rockies

    NASA Astrophysics Data System (ADS)

    Aslan, A.; Karlstrom, K. E.; Kirby, E.; Heizler, M. T.

    2012-12-01

    Basalt flows and volcanic ashes serve as a datum for calculating post-10 Ma river incision rates in western Colorado. The main picture that emerges from the data is one of regional variability of incision rates, which we hypothesize to reflect differential uplift of the Colorado Rockies during the Neogene. Maximum rates (90-180 m/Ma) and magnitudes (750-1500 m) of river incision are recorded between Grand Mesa and Glenwood Canyon, and in the Flat Tops. Minimum rates (<30 m/Ma) and magnitudes (<250 m) of river incision are associated post-Laramide normal faults within the Browns Park-Sand Wash basin in northwestern Colorado and in Middle Park of north-central Colorado. Differential uplift of the Colorado Rockies during the late Cenozoic can be inferred by comparing incision rates and magnitudes at locations upstream and downstream of knickzones. Along the Colorado River, post-10 Ma incision rates and magnitudes incision remain fairly constant (rates >100 m/Ma; magnitudes >1000 m) from Grand Mesa upstream to Gore Canyon, and then decrease markedly in Middle Park (rates <10 m/Ma; magnitudes <100 m) across the Gore Canyon knickzone. Normal-faulting of ca. 10 Ma deposits in Middle Park shows that incision rate variations partly reflect late Cenozoic faulting. Along the Yampa River, post-10 Ma incision rates and magnitudes are low (rates 15-27 m/Ma; magnitudes < 230 m) immediately upstream of Yampa Canyon, and then increase significantly (rates 96-132 m/Ma; magnitudes ~1250 m) upstream near the headwaters. We interpret this upstream increase in river incision rate and magnitude to reflect Neogene uplift of the Yampa River headwaters relative to its lower reaches. Lastly, differential late Cenozoic uplift of the Colorado Rockies is suggested by differences in the timing of regional exhumation and river incision within different drainage basins. Colorado River incision and regional exhumation occurred between 9.8 and 7.8 Ma. In contrast, Yampa River incision began between

  13. The incidence and effect of noncylindrical neck morphology on outcomes after endovascular aortic aneurysm repair in the Global Registry for Endovascular Aortic Treatment.

    PubMed

    Shutze, William; Suominem, Velipekka; Jordan, William; Cao, Piergiorgio; Oweida, Steven; Milner, Ross

    2018-05-23

    The Gore Global Registry for Endovascular Aortic Treatment (GREAT) was designed to evaluate real-world outcomes after treatment with Gore aortic endografts used in a real-world, global setting. We retrospectively analyzed the GREAT data to evaluate the incidence and effects of noncylindrical neck anatomy in patients undergoing endovascular aortic aneurysm repair. The present analysis included patients with data in the GREAT who had been treated with the EXCLUDER endograft from August 2010 to October 2016. A noncylindrical neck was defined when the proximal aortic landing zone diameter had changed ≥2 mm over the first 15 mm of the proximal landing zone, indicating a tapered, conical, or hourglass morphology. Cox multivariate regression analyses were performed for any reintervention (including reinterventions on aortic branch vessels), device-related reinterventions, and reintervention specifically for endoleak. Independent binary (cylindrical vs noncylindrical necks) and continuous (percentage of neck diameter change) variables were assessed. The abdominal aortic aneurysm (AAA) diameter, proximal neck length, maximal infrarenal neck angle, gender, and use of aortic extender cuffs were also assessed. Of 3077 GREAT patients with available proximal aortic landing zone diameter measurements available, 1765 were found to have cylindrical necks and 1312 had noncylindrical necks. The noncylindrical neck cohort had a significantly greater proportion of women (17.4% vs 12.6%; P < .001) and more severe infrarenal angulation (33.8° vs 28.4°; P < .001). A total 14.7% of noncylindrical neck patients and 11.2% cylindrical neck patients underwent implantation outside of the EXCLUDER instructions for use regarding the anatomic inclusion criteria (P = .004). The procedural characteristics were similar between the two cohorts; however, noncylindrical neck patients required significantly more aortic extender cuffs (P = .004). The average follow-up was 21.2 ± 17.5

  14. Histologic and biomechanical evaluation of a novel macroporous polytetrafluoroethylene knit mesh compared to lightweight and heavyweight polypropylene mesh in a porcine model of ventral incisional hernia repair

    PubMed Central

    Melman, L.; Jenkins, E. D.; Hamilton, N. A.; Bender, L. C.; Brodt, M. D.; Deeken, C. R.; Greco, S. C.; Frisella, M. M.

    2013-01-01

    Purpose To evaluate the biocompatibility of heavyweight polypropylene (HWPP), lightweight polypropylene (LWPP), and monofilament knit polytetrafluoroethylene (mkPTFE) mesh by comparing biomechanics and histologic response at 1, 3, and 5 months in a porcine model of incisional hernia repair. Methods Bilateral full-thickness abdominal wall defects measuring 4 cm in length were created in 27 Yucatan minipigs. Twenty-one days after hernia creation, animals underwent bilateral preperitoneal ventral hernia repair with 8 × 10 cm pieces of mesh. Repairs were randomized to Bard®Mesh (HWPP, Bard/Davol, http://www.davol.com), ULTRAPRO® (LWPP, Ethicon, http://www.ethicon.com), and GORE®INFINIT Mesh (mkPTFE, Gore & Associates, http://www.gore.com). Nine animals were sacrificed at each timepoint (1, 3, and 5 months). At harvest, a 3 × 4 cm sample of mesh and incorporated tissue was taken from the center of the implant site and subjected to uniaxial tensile testing at a rate of 0.42 mm/s. The maximum force (N) and tensile strength (N/cm) were measured with a tensiometer, and stiffness (N/mm) was calculated from the slope of the force-versus-displacement curve. Adjacent sections of tissue were stained with hematoxylin and eosin (H&E) and analyzed for inflammation, fibrosis, and tissue ingrowth. Data are reported as mean ± SEM. Statistical significance (P < 0.05) was determined using a two-way ANOVA and Bonferroni post-test. Results No significant difference in maximum force was detected between meshes at any of the time points (P > 0.05 for all comparisons). However, for each mesh type, the maximum strength at 5 months was significantly lower than that at 1 month (P < 0.05). No significant difference in stiffness was detected between the mesh types or between timepoints (P > 0.05 for all comparisons). No significant differences with regard to inflammation, fibrosis, or tissue ingrowth were detected between mesh types at any time point (P > 0.09 for all comparisons). However

  15. Unrecoverable bi-products of drilling titanium alloy and tantalum metal implants: a pilot study.

    PubMed

    Skowronek, Paweł; Olszewski, Paweł; Święszkowski, Wojciech; Synder, Marek; Sibiński, Marcin; Mazek, Jacek

    2018-05-01

    Trabecular metal implants with a porous architecture that allows for the incorporation of bone into the implant during healing are gaining popularity in alloplastic revision procedures. The bi-products of drilling titanium alloy (Ti) and tantalum (Ta) implants have not been previously assessed. Four holes were drilled in each of two spatially porous trabecular implants, one Ta and the other Ti alloy (Ti-6Al-7Nb), for this pilot in vitro study. The particles were flushed out with a continuous flow of saline. The particles' weight and the volume were then measured using a Radwag XA 110/2X (USA) laboratory balance. The total volume of the obtained metal fines was measured by titration using a 10 mm 3 measurement system. A cobalt carbide bit was used since the holes could not be made with a standard bone drill. Each Ti and Ta implant lost 1.26 g and 2.48 g of mass, respectively. The volume of free particles recovered after each stage was 280 mm 3 and 149 mm 3 , respectively. Approximately 0.6% of the total implant mass was not recovered after drilling (roughly 2% of the mass of the particles created by drilling), despite the use of 5 µm filters. It is technically difficult to drill holes in Ti and Ta implants using standard surgical tools. The drilling process creates a considerable amount of metal particles, which cannot be recovered despite intensive flushing. This may have an adverse influence on the bio-functionality (survival) of the endoprosthesis and present deleterious systemic consequences.

  16. The role of obesity, biomechanical constitution of the pelvis and contact joint stress in progression of hip osteoarthritis.

    PubMed

    Recnik, G; Kralj-Iglic, V; Iglic, A; Antolic, V; Kramberger, S; Rigler, I; Pompe, B; Vengust, R

    2009-07-01

    The aim of our study was to explore whether earlier hip arthroplasty for idiopathic osteoarthritis (OA) might be explained by enlarged contact stress in the hip joint, and to what amount can that be attributed to obesity and biomechanical constitution of the pelvis. Fifty subjects were selected from a list of consecutive recipients of hip endoprosthesis due to idiopathic OA; standard pelvic radiographs made years prior to surgery were the main selection criteria. For 65 hips resultant hip force and peak contact hip stress normalized to the body weight (R/Wb and p(max)/Wb) were determined from the radiographs with the HIPSTRESS method. Body weight and body mass index (BMI) were obtained with an interview. Regression analysis was used to correlate parameters of obesity (body weight, BMI), biomechanical constitution of the pelvis (R/Wb, p(max)/Wb) and mechanical loading within the hip joint (R, p(max)) with age at hip arthroplasty. Younger age at hip arthroplasty was associated with higher body weight (P=0.009), higher peak contact hip stress normalized to the body weight - p(max)/Wb (P=0.019), higher resultant hip force -R (P=0.027) and larger peak contact hip stress - p(max) (P<0.001), but not with BMI (P=0.121) or R/Wb (P=0.614). Our results suggest that enlarged contact stress (p(max)) plays an important role in rapid progression of hip OA with both obesity (increased body weight) and unfavorable biomechanical constitution of the pelvis (greater p(max)/Wb) contributing.

  17. Sexual function in adolescent and young adult survivors of lower extremity bone tumors.

    PubMed

    Barrera, Maru; Teall, Tanya; Barr, Ronald; Silva, Mariana; Greenberg, Mark

    2010-12-15

    Improving survival rates and new surgical options have led to increased interest regarding late effects and quality of life in adolescent and young adult survivors of bone cancers, including their sexual functioning. This study investigated sexual functioning in adolescent and young adult survivors of lower limb bone tumors, in relation to surgical treatments, gender differences, depressive symptoms, global self worth, and physical disability. Twenty-eight participants (age range 18-32 years) completed measures of gender specific sexual function, depressive symptoms, global self worth, and physical disability. For analysis, surgical intervention was grouped into limb sparing surgeries (LS; allograft fusion and endoprosthesis) and amputation or Van Nes rotationplasty (AMP). Male survivors reported significantly higher scores than females on total sexual function scores (P = 0.050), sexual drive (P = 0.002), and frequency of sexual thoughts, fantasies or erotic dreams (P = 0.021). Men also reported significantly better physical functioning scores than women (P = 0.012). LS scored significantly lower on frequency of sexual thoughts, fantasies and erotic dreams (P = 0.048) and frequency of sexual experiences (P = 0.016) compared with AMP. In addition, LS reported significantly more depressive symptoms scores (P = 0.004) and lower self worth scores (P = 0.037), than AMP. These results suggest that male survivors of lower extremity bone tumors experience better sexual functioning than women. Survivors of limb sparing surgeries struggle with sexual function, depressive symptoms, and poor self-perception compared to Van Nes rotationplasty and amputation survivors. Copyright © 2010 Wiley-Liss, Inc.

  18. Peri-prosthetic fractures around tumor endoprostheses: a retrospective analysis of eighteen cases.

    PubMed

    Barut, Nicolas; Anract, Philippe; Babinet, Antoine; Biau, David

    2015-09-01

    Tumour hip and knee endoprostheses have become the mainstay for reconstruction of patients with bone tumours. Fixation into host bone has improved over time. However, some patients present with a peri-prosthetic fracture over follow-up. The objective of this study was to analyse the mode of presentation and survival of implant after a peri-prosthetic fracture around a tumour endoprosthesis. Eighteen peri-prosthetic fractures (17 patients) were included. All patients were treated at a tertiary care center. There were 11 (65%) women; the median age at the time of fracture was 38 years old. All implants were cemented and all knee endoprostheses were fixed-hinge. Twelve (67%) fractures occurred after femoral resection and six (33%) fractures after proximal tibial resection. There were three femoral neck fractures (UCS C), three femoral shaft type C fractures, two femoral shaft type B1, one tibial shaft type B2, three tibial shaft type C, three ankle fractures (UCS C) and three patella fractures (UCS F). Two fractures were treated conservatively and 16 were operated on. Only one patient had the implant revised. There were eight (44%) failures over follow-up; none of the conservative treatment failed. The cumulative probability of failure for any reason was 27% (8-52) and 55% (22-79) at five and ten years, respectively. Peri-prosthetic fractures around massive endoprostheses are different from that of standard implants. There are more type C fractures; internal fixation is an attractive option at the time of presentation but the risk of revision over follow-up is high and patients should be informed accordingly.

  19. Globalisation and human dignity: the case of the information superhighway.

    PubMed

    Hamelink, C J

    1996-01-01

    In 1994, Vice President Al Gore coined the concept of the Information Superhighway during a speech in Buenos Aires in which he proposed the development of a global information infrastructure. The project envisions the incorporation of all existing communication networks into one system, facilitating the globalization of markets. The internet, a decentralized network of computer networks, is one small-scale, existing model of what the superhighway could be, a public space owned by nobody in which communication takes place largely for noncommercial purposes. The internet currently connects 40 million computer users from at least 90 countries. The alternative model for the superhighway is the privately managed global shopping mall, a global interactive marketplace for information, entertainment, and advertising. The author warns, however, that it is not possible to predict the future social impact of such an information superhighway. Decision makers nonetheless push ahead in development, full of confidence in the merit and infallibility of technology. Since one cannot accurately predict the future, it rational to assume that social consequences may both promote and threaten human dignity. The author explains at which level he believes the superhighway threatens the human rights norms of equality, inviolability, and liberty, and discusses what the World Association for Christian Communication can do.

  20. New role for space station—Enhanced cooperation with Russia?

    NASA Astrophysics Data System (ADS)

    Leath, Audrey T.

    The Clinton administration's recent discussions with Russia on enhanced space cooperation and a possible joint space station prompted a two-part hearing by the House Science Subcommittee on Space, held on October 6 and 14. Subcommittee members, citing rumors and news stories about a joint station, questioned Presidential Science Advisor Jack Gibbons and NASA Administrator Daniel Goldin on the status of the proposed cooperation and heard from additional witnesses regarding the feasibility of and support for the concept.Gibbons reassured subcommittee members that no decision has yet been made on Russian cooperation, and that Congress would be consulted in the process. He explained that, after the Vancouver Summit, establishment of a Joint Commission headed by Vice President Gore and Russian Prime Minister Chernomyrdin provided an opportunity for enhanced cooperation in space, as well as in such other areas as energy, nuclear safety, the environment, business development, science and technology, and defense diversification. Gibbons testified that the study of a cooperative station program took place concurrently with NASA's work on defining the redesigned U.S. space station, now being referred to as “Alpha.” He affirmed that while Alpha's modular design made it adaptable to a joint effort, it could “be built independent of any Russian participation.”

  1. Pharmacy in Space: A Session on NASA Technologies

    NASA Technical Reports Server (NTRS)

    Richmond, Robert C.

    1998-01-01

    In 1993, Vice-president Gore was charged with creation of a correctional plan for the poor findings from an efficiency study of governmental agencies. That correctional analysis was then used to support efforts to balance the budget in ways anticipated to improve the value returned per tax payer dollar spent. The final result was a broad initiative collectively termed "reinventing the government", which included major restructuring within NASA as well, termed "reinventing NASA This included substantial elimination of middle management and downsizing such that about 2 million government workers employed in 1992 has shrunk now to about 1.2 million government workers who are employed in ways that at least somewhat decrease bureaucratic and programmatic inefficiencies. Today, "reinvented NASA" has an awareness of contractual commitment to the public. NASA now operates within a so-called "strategic plan" that requires awareness and response to domestic needs. This is important to this audience because it means that NASA is committed to exploring interactions that you may wish to initiate. That is, you are urged to explore with NASA on topics of educational support, collaborative research, or commercial partnerships in drug development and application, as the pertinent examples here, in ways that can include involvement of central NASA resources and missions.

  2. Conceptual design of a self-deployable, high performance parabolic concentrator for advanced solar-dynamic power systems

    NASA Astrophysics Data System (ADS)

    Dehne, Hans J.

    1991-05-01

    NASA has initiated technology development programs to develop advanced solar dynamic power systems and components for space applications beyond 2000. Conceptual design work that was performed is described. The main efforts were the: (1) conceptual design of self-deploying, high-performance parabolic concentrator; and (2) materials selection for a lightweight, shape-stable concentrator. The deployment concept utilizes rigid gore-shaped reflective panels. The assembled concentrator takes an annular shape with a void in the center. This deployable concentrator concept is applicable to a range of solar dynamic power systems of 25 kW sub e to in excess of 75 kW sub e. The concept allows for a family of power system sizes all using the same packaging and deployment technique. The primary structural material selected for the concentrator is a polyethyl ethylketone/carbon fiber composite also referred to as APC-2 or Vitrex. This composite has a nearly neutral coefficient of thermal expansion which leads to shape stable characteristics under thermal gradient conditions. Substantial efforts were undertaken to produce a highly specular surface on the composite. The overall coefficient of thermal expansion of the composite laminate is near zero, but thermally induced stresses due to micro-movement of the fibers and matrix in relation to each other cause the surface to become nonspecular.

  3. Kinetics of common inflammatory biomarkers in postoperative course after congenital heart defects procedures with extracorporeal circulation in children.

    PubMed

    Haponiuk, Ireneusz; Jaworski, Radosław; Paczkowski, Konrad; Chojnicki, Maciej; Steffens, Mariusz; Szofer-Sendrowska, Aneta; Gierat-Haponiuk, Katarzyna; Kwaśniak, Ewelina; Paśko-Majewska, Marta; Leszczyńska, Katarzyna; Zieliński, Jacek; Szymanowicz, Wiktor

    2018-02-05

    The extracorporeal circulation is associated with systemic inflammatory response syndrome. Therefore, the diagnosis of infection should be differenced from typical postoperative course. Evaluation of kinetics of inflammatory biomarkers in children in the first days after cardiac surgery with extracorporeal circulation. Prospective data collection from 51 consecutive children referred for surgical treatment [the Institution], between February 2015 and August 2015. Blood samples were collected in the first, second and third postoperative days and send to institutional laboratory for routine lab-tests: white blood cells count, serum C-reactive protein and procalcitonin concentration. The highest levels of procalcitonin were in the first postoperative day (median 3,53 ng/mL), although the peak values of C-reactive protein concentration and white blood cells count were in the second postoperative day (as follows 96mg/L and 17,3 G/L). In the group of patients with foreign material implantation (Contegra® or Gore-Tex®), the higher values of procalcitonin concentration and white blood cells count were measured in the further postoperative days. Kinetics of analyzed inflammatory biomarkers in the first days after cardiac surgery for congenital heart disease in children have different characteristics. The knowledge about inflammatory biomarkers' kinetics could be useful in determining the possibility of evolving infections in the early postoperative period.

  4. Conceptual design study of a 5 kilowatt solar dynamic Brayton power system using a dome Fresnel lens solar concentrator

    NASA Technical Reports Server (NTRS)

    Oneill, Mark J.; Mcdanal, A. J.; Spears, Don H.

    1989-01-01

    The primary project objective was to generate a conceptual design for a nominal 5 kW solar dynamic space power system, which uses a unique, patented, transmittance-optimized, dome-shaped, point-focus Fresnel lens as the optical concentrator. Compared to reflective concentrators, the dome lens allows 200 times larger slope errors for the same image displacement. Additionally, the dome lens allows the energy receiver, the power conversion unit (PCU), and the heat rejection radiator to be independently optimized in configuration and orientation, since none of these elements causes any aperture blockage. Based on optical and thermal trade studies, a 6.6 m diameter lens with a focal length of 7.2 m was selected. This lens should provide 87 percent net optical efficienty at 800X geometric concentration ratio. The large lens is comprised of 24 gores, which compactly stow together during launch, and automatically deploy on orbit. The total mass of the microglass lens panels, the graphite/epoxy support structure, and miscellaneous hardware is about 1.2 kg per square meter of aperture. The key problem for the dome lens approach relates to the selection of a space-durable lens material. For the first time, all-glass Fresnel lens samples were successfully made by a sol-gel casting process.

  5. Geochemistry of volcanic gas from Avachinsky volcano (Kamchatka, Russia)

    NASA Astrophysics Data System (ADS)

    Chaplygin, Ilya; Taran, Yuri; Lavrushin, Vasily; Inguaggiato, Salvatore

    2015-04-01

    Among 29 active volcanoes on Kamchatka Avachinsky volcano (2741 m) attracts more attention that others due to its proximity (25 km) to Petropavlovsk-Kamchatsky, the biggest city on Kamchatka. The last eruption at Avacha occurred in summit crater in January 1991. It produced small lava flow and left lava plug, which cracked in 2001. Gas emissions from the crack and fumarolic sites at Avachinsky has been monitored from 1994 (Malik, Zelensky, 2014). Previous data show that gas temperature increase (T°C): 473 (09.94), 416 (08.97), 400 (08.99), 500 (10.01), 626 (09.13). We present chemical and isotopic data on gas and condensate samples taken from the hottest fumarole at Avacha (630°C) in July 2014 (mol.%): H2O 96.46, CO2 1.55, SO2 1.32, HCl 0.27, HF 0.02, H2 0.28; δ18O 2.28‰, δD -48.8‰. According to data available gas from Avacha is close to magmatic fluid of subduction zone volcanoes. ICP data on condensate collected allow to intercompare metal-bearing capacity of high-temperature gases from Avacha, Gorely, Tolbachik and Kudriavy volcanoes. The study is supported by RFBR, grant 14-05-00874.

  6. A One-Piece Lunar Regolith Bag Garage Prototype

    NASA Technical Reports Server (NTRS)

    Smithers, G. A.; Nehls, M. K.; Hovater, M. A.; Evans, S. W.; Miller, J. S.; Broughton, R. M., Jr.; Beale, D.; Kilinc-Balci, F.

    2007-01-01

    Shelter structures on the moon, even in early phases of exploration, should incorporate lunar materials as much as possible. This Technical Memorandum details the design and construction of a prototype for a one-piece regolith bag unpressurized garage concept and a materials testing program to investigate six candidate fabrics to learn how they might perform in the lunar environment. The conceptualization was that a lightweight fabric form be launched from Earth and landed on the lunar surface to be robotically filled with raw lunar regolith. Regolith bag fabric candidates included: Vectran(TM), Nextel(TM), Gore PTFE Fabric(TM), Zylon(TM), Twaron(TM), and Nomex(TM). Tensile (including post radiation exposure), fold, abrasion, and hypervelocity impact testing were performed under ambient conditions, and also performed under cold and elevated temperatures. In some cases, Johnson Space Center lunar simulant (JSC-1) was used in conjunction with testing. A series of preliminary structures was constructed during final prototype design based on the principles of the classic masonry arch. The prototype was constructed of Kevlar(TM) and filled with vermiculite. The structure is free-standing, but has not yet been load tested. Future plans would be to construct higher fidelity prototypes and to conduct appropriate tests of the structure.

  7. Conceptual design of a self-deployable, high performance parabolic concentrator for advanced solar-dynamic power systems

    NASA Technical Reports Server (NTRS)

    Dehne, Hans J.

    1991-01-01

    NASA has initiated technology development programs to develop advanced solar dynamic power systems and components for space applications beyond 2000. Conceptual design work that was performed is described. The main efforts were the: (1) conceptual design of self-deploying, high-performance parabolic concentrator; and (2) materials selection for a lightweight, shape-stable concentrator. The deployment concept utilizes rigid gore-shaped reflective panels. The assembled concentrator takes an annular shape with a void in the center. This deployable concentrator concept is applicable to a range of solar dynamic power systems of 25 kW sub e to in excess of 75 kW sub e. The concept allows for a family of power system sizes all using the same packaging and deployment technique. The primary structural material selected for the concentrator is a polyethyl ethylketone/carbon fiber composite also referred to as APC-2 or Vitrex. This composite has a nearly neutral coefficient of thermal expansion which leads to shape stable characteristics under thermal gradient conditions. Substantial efforts were undertaken to produce a highly specular surface on the composite. The overall coefficient of thermal expansion of the composite laminate is near zero, but thermally induced stresses due to micro-movement of the fibers and matrix in relation to each other cause the surface to become nonspecular.

  8. The Hammer Award is presented to KSC and 45th Space Wing.

    NASA Technical Reports Server (NTRS)

    1999-01-01

    At a special presentation in the IMAX 2 Theater in the Kennedy Space Center Visitor Complex, the Hammer Award is presented to Kennedy Space Center and the 45th Space Wing. Among the attendees in the audience are (center) Center Director Roy D. Bridges Jr., flanked by (at left) Commander of the 45th Space Wing Brig. Gen. F. Randall Starbuck and (at right) Commander of the Air Force Space Command General Richard B. Myers. Standing second from right is NASA Administrator Daniel S. Goldin. At the far right is Morley Winograd, director of the National Partnership for Reinventing Government, who presented the award. The Hammer Award is Vice President Al Gore's special recognition of teams of federal employees who have made significant contributions in support of the principles of the National Partnership for Reinventing Government. This Hammer Award acknowledges the accomplishments of a joint NASA and Air Force team that established the Joint Base Operations and Support Contract (J- BOSC) Source Evaluation Board (SEB). Ed Gormel and Chris Fairey, co-chairs of the SEB, accepted the awards for the SEB. The team developed and implemented the acquisition strategy for establishing a single set of base operations and support service requirements for KSC, Cape Canaveral Air Station and Patrick Air Force Base.

  9. (Re)inventing Government-Industry R and D Collaboration

    NASA Technical Reports Server (NTRS)

    Holmes, Bruce J.

    1996-01-01

    This paper describes the lessons learned in developing and operating a large-scale strategic alliance whose organization and coordination is U.S. Government-led using new means for R&D collaboration. Consortia in the United States counter a century of 1884 Sherman Anti-Trust Law-based governmental and legal policy and a longstanding business tradition of unfettered competition. Success in public-private collaboration in America requires compelling vision and motivation by both partners to reinvent our ways of doing business. The foundations for reinventing government and alliance building were laid in 1994 with Vice President Al Gore's mandates for Federal Lab Reviews and other examinations of the roles and missions for the nation's more than 700 government labs. In addition, the 1984 National Cooperative Research Act (NCRA) set in motion the abilities for U.S. companies to collaborate in pre-competitive technology development. The budget realities of the 1990's for NASA and other government agencies demand that government discover the means to accomplish its mission by leveraging resources through streamlining as well as alliances. Federal R&D investments can be significantly leveraged for greater national benefit through strategic alliances with industry and university partners. This paper presents early results from one of NASA's first large-scale public/private joint R&D ventures.

  10. The Emergence Of The National Research And Education Network (NREN) And Its Implications For American Telecommunications

    NASA Astrophysics Data System (ADS)

    Maloff, Joel H.

    1990-01-01

    "The nation which most completely assimilates high performance computing into its economy will very likely emerge as the dominant intellectual, economic, and technological force in the next century", Senator Albert Gore, Jr., May 18, 1989, while introducing Senate Bill 1067, "The National High Performance Computer Technology Act of 1989". A national network designed to link supercomputers, particle accelerators, researchers, educators, government, and industry is beginning to emerge. The degree to which the United States can mobilize the resources inherent within our academic, industrial and government sectors towards the establishment of such a network infrastructure will have direct bearing on the economic and political stature of this country in the next century. This program will have significant impact on all forms of information transfer, and peripheral benefits to all walks of life similar to those experienced from the moon landing program of the 1960's. The key to our success is the involvement of scientists, librarians, network designers, and bureaucrats in the planning stages. Collectively, the resources resident within the United States are awesome; individually, their impact is somewhat more limited. The engineers, technicians, business people, and educators participating in this conference have a vital role to play in the success of the National Research and Education Network (NREN).

  11. Trial Vocal Fold Injection Predicts Thyroplasty Outcomes in Nonparalytic Glottic Incompetence.

    PubMed

    Dumberger, Lukas D; Overton, Lewis; Buckmire, Robert A; Shah, Rupali N

    2017-04-01

    Trial vocal fold injection (TVFI) may be used prior to permanent medialization when voice outcome is uncertain. We aimed to determine whether voice outcomes of TVFI are predictive of, or correlate with outcomes after type I Gore-Tex medialization thyroplasty (GMT) in patients with nonparalytic glottic incompetence (GI). Thirty-five patients with nonparalytic GI who underwent TVFI followed by GMT were retrospectively reviewed. Change in voice-related quality of life (VRQOL) after TVFI was compared to change in VRQOL 3 to 9 months after GMT. Similar comparisons were made for change in glottal function index (GFI) and change in grade, roughness, breathiness, asthenia, and strain (GRBAS). Sample correlation coefficients were calculated. Change in VRQOL after TVFI showed good correlation with change in VRQOL after GMT, r = 0.55. Change in GFI after TVFI showed strong correlation with change in GFI after GMT, r = 0.74. Change in GRBAS after TVFI showed excellent correlation with change in GRBAS after GMT, r = 0.90. The TVFI is a useful tool in nonparalytic GI when outcomes from glottic closure procedures are not clear. Voice outcome measures after TVFI strongly correlate with outcomes from GMT. These data may be used to more confidently counsel patients regarding their predicted outcomes of permanent medialization.

  12. Preliminary design notes on a low F-number EMR

    NASA Technical Reports Server (NTRS)

    Mihora, D. J.

    1982-01-01

    Conceptual design studies were completed on a new Electrostatic Membrane Reflector, EMR. This new model incorporates both a preformed, curved membrane reflector and membrane control surface. This improved model is the second step toward a high precision large space antenna that could eventually exhibit a performance in terms of aperture diameter to surface quality exceeding 1,000,000. Design trades indicate that the goal of a low ratio of focal length to aperture diameter (f sub n) can be achieved while operating in a humid sea-level environment. A nominal surface quality of 1.0 mm (RMS) is possible using available off-the-shelf commercial membranes. Both the membrane reflector and control electrode surface are fabricated from 12 gore segments and attached to the available 12 sided, 4.88 m diameter rim. The preferred conceptual design has a f sub n = 1.0. The 4.88 m aperture is performed with a centerline displacement of 0.306 m. The nominal spacing between the membrane reflector and the electrode control surface is 50.8 mm. The centerline membrane displacement from its performed to its tensioned, smooth shape is about 3 mm. The membrane tensioning is achieved by application of an electrostatic pressure of 2.6 N/sq cm and a voltage of about 38 kV.

  13. KSC-99pp0838

    NASA Image and Video Library

    1999-07-16

    At a special presentation in the IMAX 2 Theater in the Kennedy Space Center Visitor Complex, the Hammer Award is presented to Kennedy Space Center and the 45th Space Wing. Among the attendees in the audience are (center) Center Director Roy D. Bridges Jr., flanked by (at left) Commander of the 45th Space Wing Brig. Gen. F. Randall Starbuck and (at right) Commander of the Air Force Space Command General Richard B. Myers. Standing second from right is NASA Administrator Daniel S. Goldin. At the far right is Morley Winograd, director of the National Partnership for Reinventing Government, who presented the award. The Hammer Award is Vice President Al Gore's special recognition of teams of federal employees who have made significant contributions in support of the principles of the National Partnership for Reinventing Government. This Hammer Award acknowledges the accomplishments of a joint NASA and Air Force team that established the Joint Base Operations and Support Contract (J-BOSC) Source Evaluation Board (SEB). Ed Gormel and Chris Fairey, co-chairs of the SEB, accepted the awards for the SEB. The team developed and implemented the acquisition strategy for establishing a single set of base operations and support service requirements for KSC, Cape Canaveral Air Station and Patrick Air Force Base

  14. Skin maintenance in the bed-ridden patient.

    PubMed

    Flam, E

    1990-01-01

    The skin of a patient at risk of developing pressure ulcers can resist deterioration if the conditions that weaken it are controlled. The purpose of this study is to determine the relationships between hydration level, skin temperature, and friction in patients at risk of development or reoccurrence of pressure ulcers and in patients with newly created surgical flaps. Two systems were considered: the standard hospital mattress covered with a thick occlusive plastic film and a 50/50 cotton/polyester bed sheet and the KinAir and the TheraPulse support systems with nylon/High Air Loss GORE-TEX (n/HAL) laminate cushions and coverlets. The moisture vapor management and aeration capabilities of the support system materials were determined, and the frictional force generated against the skin was measured. The results revealed that excessive hydration increases the level of friction against the skin while at the same time reducing the mechanical properties of the protective skin layers. The n/HAL laminate coverlet also had a significantly lower skin friction coefficient than the 50/50 cotton/polyester bed sheet. The significance of these findings is that over-hydration accelerates the abrading action on the skin by increasing the frictional force and decreasing the shear resistance of the skin.

  15. A humidity controlled Nephelometer system to study the hygroscopic properties of aerosols in the marine environment

    NASA Astrophysics Data System (ADS)

    Vaishya, Aditya; O'Dowd, Colin; Jennings, S. Gerard

    2010-05-01

    A Humidograph system has been designed to study the hygroscopic properties of aerosols for different air-masses and for different seasons in the marine environment. Since ambient marine aerosols are likely to be found in a metastable state, and in accordance with recommendations of WMO/GAW to sample dry aerosol, a drying unit (Nafion based) is placed just after the inlet to dry the aerosols to a relative humidity (RH) < 40% so as not to misinterpret the optical properties of hygroscopic aerosols if they are on the descending branch of the hysteresis curve. The flow after the dryer is split into two, one going to a 3-wavelength TSI-3563 Integrating Nephelometer, and the other to a Gore-Tex based humidifier followed by a single-wavelength TSI-3561 Integrating Nephelometer. The humidifier is used to vary the RH from 40% to 90%. While the TSI-3563 Integrating Nephelometer will operate at RH < 40%, the TSI-3561 Integrating Nephelometer will operate under varying RH conditions. Software developed in LabVIEW is used to control the hardware components and to log the data in a predefined format. Results of the performance of the Humidograph system in the laboratory and at the Mace Head Atmospheric Research Station are presented.

  16. [Ceramic-ceramic articulation in uncemented total hip arthroplasty].

    PubMed

    Synder, Marek; Drobniewski, Marek; Kozłowski, Piotr; Grzegorzewski, Andrzej

    2005-01-01

    The main problem in total hip arthroplasty (THA) surgery is aseptic loosening of prosthesis components. In most cases the phagocytes reaction against the wear particle during the hip movement is responsible for aseptic prosthesis loosening. To prevent this reaction different hip articulation are invented to reduce this reaction. One of these solutions is ceramic-ceramic hip prosthesis articulation. The aim of this study was to evaluate the long-term results in patients who were treated because of coxarthrosis by means of ceramic-ceramic hip prosthesis. We analyzed 258 primary THA (222 patients, 116 women and 106 men) who were treated because of advanced coxarthrosis by Mittelmeier type hip endoprosthesis (ceramic-ceramic articulation). The mean age of patients at the surgery was 45.6 years and a mean follow-up 10.2 years. In most of our cases the idiopathic, traumatic and dysplastic coxarthrosis was noted. For clinical evaluation the classification system proposed by Merle d'Aubigne and Postel with Charnley modification was used. For radiological evaluation of the steam implantation the classification system proposed by De Lee and Charnley was used and for the cup implantation the system by Gruen and Moreland. In 87 patients (33.7%) the final results was graded as very good, in 96 (37.2%) as good, in 47 (18.2%) as satisfactory and in 28 patients (10.9%) the final results was poor. In analyzed group in 13 patients (5.0%) the revision surgery was necessary. The long-term results of THA with the use of Mittelmeier type of hip prosthesis presented a very low percentage of aseptic loosening. This type of prosthesis gives very high patients satisfaction.

  17. Direct influence of titanium and zirconia particles on the morphology and functionality of mature human osteoclasts.

    PubMed

    Pasold, Juliane; Markhoff, Jana; Tillmann, Jenny; Krogull, Martin; Pisowocki, Phillip; Bader, Rainer

    2017-09-01

    Within the last ten years of biomedical implants, the focus is increasingly on bioceramics, specifically on zirconia (ZrO 2 ). Hence, we analyzed the impact of ZrO 2 particles in comparison to titanium particles on mature human osteoclasts (OCs) as little is known about the direct effect of wear particles on mature OCs and their role in the osteolytic process during aseptic endoprosthesis loosening. Changes in cell morphology and functionality of OCs incubated with particles in different concentrations were investigated in vitro. OCs tend to be enlarged after three days of cultivation with both types of particles, especially with high concentrations of ZrO 2 , suggesting increased cell fusion. Further, we identified significantly increased expression of OC specific and bone matrix related genes: VNR, RANK, TRAP, and CTSK pointing on a direct stimulatory particle effect on the functionality of mature OCs. In completion, we quantified the bone resorption activity of particle treated mature OCs but could not detect a significant difference in bone resorption compared to OCs cultivated without particles. However, we could identify significantly higher gene expression of MMP-1 in particle treated OCs compared to untreated control OCs after three days of incubation. We also detected an impaired production of the tissue inhibitor of metalloproteinase, especially for OCs treated with high ZrO 2 concentrations. In conclusion, our in vitro data show that abrasion particles could have a direct influence on mature OCs and therefore could promote increased OC-mediated bone resorption during aseptic loosening of total joint replacements. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 2608-2615, 2017. © 2017 Wiley Periodicals, Inc.

  18. Knee arthrodesis using a vascularized fibular rotatory graft after tumor resection.

    PubMed

    Nouri, H; Meherzi, M H; Jenzeri, M; Daghfous, M; Hdidane, R; Zehi, K; Tarhouni, L; Karray, S; Baccari, S; Mestiri, M; Zouari, M

    2010-02-01

    Knee arthrodesis is one of the reconstruction options for limb preservation after malignant tumor resection. Vascularised rotatory fibular transfer allows biological and, thus,definitive reconstruction. The goal of this work was to analyse the results of knee arthrodesis with vascularised fibular graft after tumor resection and to discuss the reliability of this technique. We report a retrospective series of 13 patients with an average age of 29.6 years. The pathological diagnosis was bone sarcoma in 12 cases and synovial chondrosarcoma in one case. Resection/arthrodesis was undertaken as the primary procedure in 11 cases.In two cases, arthrodesis was indicated after failure of an endoprosthesis. Reconstruction was achieved with a vascularised fibular rotatory transfer in all cases. For stabilisation, an external fixator was utilised in eight cases, a femorotibial nail in three cases, and a plate in two cases.Mean follow-up was 6 years. We encountered infection in 53% of cases, mechanical complications in 53% of cases,and nerve palsy in 23% of cases. Four patients died from metastases (only one had arthrodesis complete union). In the nine surviving patients, arthrodesis was fully united in seven cases,after an average period of 36 months. The functional score average (Enneking classification)was 20 points. Knee arthrodesis after tumor resection is a complex technique. Septic complications and mechanical failure are frequent regardless of the technique employed. They are related to the extent of bone sacrifice but also to that of soft tissues. The use of vascularised fibula alone and stabilisation by external fixation were the main shortcomings in this series. TYPE OF STUDY RETROSPECTIVE: Level IV. 2009 Published by Elsevier Masson SAS.

  19. Arthrodesis After Infected Revision TKA: Retrospective Comparison of Intramedullary Nailing and External Fixation.

    PubMed

    Iacono, Francesco; Francesco, Iacono; Raspugli, Giovanni Francesco; Francesco, Raspugli Giovanni; Bruni, Danilo; Danilo, Bruni; Lo Presti, Mirco; Mirco, Lo Presti; Sharma, Bharat; Bharat, Sharma; Akkawi, Ibrahim; Ibrahim, Akkawi; Marcacci, Maurilio; Maurilio, Marcacci

    2013-10-01

    Infection after revision total knee arthroplasty (TKA) for previous septic TKA can be a challenging problem to treat due to loss of bone stock and soft tissue integrity. In these cases, arthrodesis is a well-recognized salvage procedure. The aim of this retrospective study was to compare the results as described by a Visual Analogue Scale (VAS) and the Lequesne Algofunctional Score (LAS) of knee arthrodeses performed by using either an external fixator (EF) or an intramedullary nail (IM). The study included 34 knee arthrodesis divided in two groups: first group included 12 patients treated with EF and the second group of 22 patients dealt with IM nail. Clinical and functional evaluation was performed using the VAS and the LAS. Full-length radiographs were used to verify limb length discrepancy. VAS and LAS results showed a substantial improvement relative to preoperative condition in both groups. However, the LAS was significantly better in the IM nail group. The mean leg length discrepancy was significantly greater (4.5 cm) in the first group than in the second one (0.8 cm). No recurrence of infection was observed in the EF group while there were three recurrent infections in the IM nail group. Our study supported the existing literature and found that reinfection after revision TKA can be effectively treated with arthrodesis. In presence of massive bone loss, we recommend arthrodesis with IM nail used as an endoprosthesis, without bone-on-bone fusion, to produce a stable and painless knee, while preserving the limb length. Use of an IM nail allowed us to get a better functional result than EF.

  20. [External biliary fistulas selectively managed by endoscopic retrograde cholangiography with sphincterotomy and/or stent placement].

    PubMed

    Săftoiu, A; Gheonea, D I; Surlin, V; Ciurea, M E; Georgescu, A; Andrei, E; Blendea, A; Georgescu, C C; Georgescu, I; Ciurea, T

    2006-01-01

    External bile duct fistulas are inherent postoperative complications that usually appear after biliary tract surgery, traumatic bile duct injuries and liver surgery for hepatic hydatid disease or liver transplant. The management is highly individualized, while the success and long-term results of endoscopic and surgical techniques are conflicting. The study included 32 cases with external bile duct fistulas managed by endoscopic retrograde cholangiography (ERC) with sphincterotomy and/or stent placement, including "rendez-vous" procedures in 2 cases. The causes of the external fistula were represented by cholecystectomy with/without retained common bile duct stones or strictures (22 cases), cholecystectomy and drainage of a subphrenic abscess caused by severe acute pancreatitis (1 case) and surgical interventions for hepatic hydatid disease (9 cases). Due to the prospective protocol of the study we were able to apply an individualized endoscopic treatment: sphincterotomy with proper relief of the bile duct obstruction (stone extraction) or sphincterotomy with large-size (10 Fr) stent placement for large-sized bile duct defects. The results consisted in closure of the fistula in 3.5 +/- 1.7 days for the subgroup of patients with sphincterotomy alone. Among the patients with stent insertion, fistulas healed slower in 14 +/- 3.5 days. There were no complications after endoscopic treatment; however the stent could not be passed in one patient that required subsequent surgery. In conclusion, endoscopic intervention is the treatment of choice for small external biliary fistulas complicating biliary tract surgery or liver surgery for hepatic hydatid disease. When the fistula is large, the placement of a 10 Fr endoprosthesis becomes necessary, while failure of endoscopic treatment leads to surgery with hepatico-jejunal anastomosis.

  1. International Volcanological Field School: Introduction to Geohazard Research and Monitoring

    NASA Astrophysics Data System (ADS)

    Izbekov, P. E.; Kravchunovskaya, E. A.; Eichelberger, J. C.; Gordeev, E.; Novik, Y. O.; Chebrov, V. N.

    2012-12-01

    The Kurile-Kamchatka-Aleutian- Alaska portion of the Pacific Rim of Fire spans nearly 5,400 km. It is home for more than 110 active volcanoes, which produce 4-6 significant explosive eruptions per year. It is also the source of some of the largest tsunami-generating earthquakes in the history of mankind. Volcanic ash clouds and tsunami waves generated in this area travel for thousands of kilometers defying political boundaries, thus making the international cooperation crucial for mitigating geohazards in the Northern Pacifica. In 2003, the University of Alaska Fairbanks, the Institute of Volcanology and Seismology, the Vitus Bering Kamchatka State University, with strong support from the Kamchatka Branch of the Geophysical Survey of the Russian Academy of Sciences, have established the International Volcanological Field School. This field camp serves as an introduction to volcanology and covers fundamental aspects of geohazard research and monitoring. Offered at both sides of the Russia-US border, the School attracts students from various disciplines and cultures, providing a direct access to the best examples of explosive volcanism at Katmai National Park in Alaska and at Mutnovsky & Gorely volcanoes in Kamchatka. It complements our efforts to build a strong geoscience community in the Northern Pacifica and serves as an important tool to attract brightest young scientists to geohazard research and monitoring.

  2. The current state of the Russian reduced enrichment research reactors program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aden, V.G.; Kartashov, E.F.; Lukichev, V.A.

    1997-08-01

    During the last year after the 16-th International Conference on Reducing Fuel Enrichment in Research Reactors held in October, 1993 in Oarai, Japan, the conclusive stage of the Program on reducing fuel enrichment (to 20% in U-235) in research reactors was finally made up in Russia. The Program was started late in 70th and the first stage of the Program was completed by 1986 which allowed to reduce fuel enrichment from 80-90% to 36%. The completion of the Program current stage, which is counted for 5-6 years, will exclude the use of the fuel enriched by more than 20% frommore » RF to other countries such as: Poland, Czeck Republick, Hungary, Roumania, Bulgaria, Libya, Viet-Nam, North Korea, Egypt, Latvia, Ukraine, Uzbekistan and Kazakhstan. In 1994 the Program, approved by RF Minatom authorities, has received the status of an inter-branch program since it was admitted by the RF Ministry for Science and Technical Policy. The Head of RF Minatom central administrative division N.I.Ermakov was nominated as the Head of the Russian Program, V.G.Aden, RDIPE Deputy Director, was nominated as the scientific leader. The Program was submitted to the Commission for Scientific, Technical and Economical Cooperation between USA and Russia headed by Vice-President A. Gore and Prime Minister V. Chemomyrdin and was given support also.« less

  3. Clinical effectiveness and safety of collagen sheet for dorsal augmentation in rhinoplasty.

    PubMed

    Chang, Chul; Kong, Won Kyoung

    2014-09-01

    In Asian rhinoplasty, dorsal augmentation often requires the use of alloplastic materials because sufficient amounts of autograft are difficult to harvest. Given considerations of aesthetics, costs, and the characteristics of the oriental nose, silicone or Gore-Tex is commonly used when augmenting the nasal dorsum to a great extent. Such materials can often result in postoperative complications and foreign-body sensations. Moreover, extrusion or visualization of the implant may occur because of thinning of the skin over time. Permacol collagen implants are specifically indicated for soft tissue reinforcement and repair of the head and face in plastic and reconstructive surgery. The handling versatility of the flexible collagen sheet allows it to be layered over itself until the requisite thickness and desired shape are obtained. A total of 50 patients who underwent nasal augmentation rhinoplasty between December 2007 and May 2011 were observed for at least 24 months. Depending on the nasal dorsum, we layered the collagen sheet up to a maximum of 4 times and we have not seen any case of severe resorption or overcorrection in the nasal configuration. Collagen implant material is safe for use in select rhinoplasty patients because of its low complication rate, as shown in our series. It could therefore be considered as a useful alternative when reconstruction is problematic because of the low quality or lack of available autologous grafts.

  4. Balloon Design Software

    NASA Technical Reports Server (NTRS)

    Farley, Rodger

    2007-01-01

    PlanetaryBalloon Version 5.0 is a software package for the design of meridionally lobed planetary balloons. It operates in a Windows environment, and programming was done in Visual Basic 6. By including the effects of circular lobes with load tapes, skin mass, hoop and meridional stress, and elasticity in the structural elements, a more accurate balloon shape of practical construction can be determined as well as the room-temperature cut pattern for the gore shapes. The computer algorithm is formulated for sizing meridionally lobed balloons for any generalized atmosphere or planet. This also covers zero-pressure, over-pressure, and super-pressure balloons. Low circumferential loads with meridionally reinforced load tapes will produce shapes close to what are known as the "natural shape." The software allows for the design of constant angle, constant radius, or constant hoop stress balloons. It uses the desired payload capacity for given atmospheric conditions and determines the required volume, allowing users to design exactly to their requirements. The formulations are generalized to use any lift gas (or mixture of gases), any atmosphere, or any planet as described by the local acceleration of gravity. PlanetaryBalloon software has a comprehensive user manual that covers features ranging from, but not limited to, buoyancy and super-pressure, convenient design equations, shape formulation, and orthotropic stress/strain.

  5. Initial experience in the treatment of thoracic aortic aneurysmal disease with a thoracic aortic endograft at Baylor University Medical Center.

    PubMed

    Apple, Jeffrey; McQuade, Karen L; Hamman, Baron L; Hebeler, Robert F; Shutze, William P; Gable, Dennis R

    2008-04-01

    A retrospective review of 27 patients who underwent endovascular repair of thoracic aneurysms and of other thoracic aortic pathology with the thoracic aortic endograft (Gore Medical, Flagstaff, AZ) from June 2005 to July 2007 was performed. The mean follow-up period was 13.5 months (range, 2-25 months). Indications for thoracic endografting included descending thoracic aneurysms (n = 18), thoracoabdominal aneurysms (n = 3), traumatic aortic injuries (n = 3), penetrating aortic ulcers (n = 2), and contained rupture of a type B dissection (n = 1). One patient died during the procedure, for an overall mortality rate of 3.7%. The average length of stay was 8.1 days, with an average stay in the intensive care unit of 4.2 days. If patients with traumatic aortic injuries were excluded, the average overall and intensive care unit length of stay were 5.6 and 1.8 days, respectively. There was one incident of spinal cord ischemia (3.7%). There were five type I or type III endoleaks, three of which required revision (11.1%). In conclusion, thoracic endografting is a safe and viable option for the repair of descending thoracic aneurysms and other aortic pathologies. We have found it to be less invasive, even in conjunction with preoperative debranching procedures, with a shorter recovery time, decreased perioperative morbidity and blood loss, and decreased peri-operative mortality compared with standard open repair.

  6. The Strategic Combination of Open-Access Peer-Review, Mainstream Media and Social Media to Improve Public Climate Literacy (Invited)

    NASA Astrophysics Data System (ADS)

    Cook, J.; Nuccitelli, D. A.; Jacobs, P.

    2013-12-01

    The Skeptical Science website began in 2007, with the goal of refuting climate misinformation with peer-reviewed science. It achieved this by embracing a diversity of message formats and delivery methods. Myth rebuttals are available at beginner, intermediate and advanced levels, spanning from long, technical treatments to tweetable one-liners. Content has been translated into 20 different languages and made available via the web, an iPhone app and books while adopted by third parties in textbooks, university and MOOC curricula, books, Senate testimonies and TV documentaries. While social media has been a fruitful medium, we experimented with a new model in 2013, employing the strategic combination of open-access peer-review, mainstream media outreach and social media marketing. This strategy was adopted with the release of a paper quantifying the level of scientific consensus in published climate papers, resulting in broad mainstream media attention as well as acknowledgement from key public figures such as Al Gore, the UK Minister for Energy Edward Davey and President Obama. Our approach was informed by psychological research into both the importance of scientific consensus and how to reduce the influence of misconceptions. While multiple methods of delivery are important, equally important is the construction of the messages themselves. I will examine the science of crafting compelling messages and how combination with diverse message delivery can lead to impactful outcomes.

  7. Initial experience in the treatment of thoracic aortic aneurysmal disease with a thoracic aortic endograft at Baylor University Medical Center

    PubMed Central

    Apple, Jeffrey; McQuade, Karen L.; Hamman, Baron L.; Hebeler, Robert F.; Shutze, William P.

    2008-01-01

    A retrospective review of 27 patients who underwent endovascular repair of thoracic aneurysms and of other thoracic aortic pathology with the thoracic aortic endograft (Gore Medical, Flagstaff, AZ) from June 2005 to July 2007 was performed. The mean follow-up period was 13.5 months (range, 2–25 months). Indications for thoracic endografting included descending thoracic aneurysms (n = 18), thoracoabdominal aneurysms (n = 3), traumatic aortic injuries (n = 3), penetrating aortic ulcers (n = 2), and contained rupture of a type B dissection (n = 1). One patient died during the procedure, for an overall mortality rate of 3.7%. The average length of stay was 8.1 days, with an average stay in the intensive care unit of 4.2 days. If patients with traumatic aortic injuries were excluded, the average overall and intensive care unit length of stay were 5.6 and 1.8 days, respectively. There was one incident of spinal cord ischemia (3.7%). There were five type I or type III endoleaks, three of which required revision (11.1%). In conclusion, thoracic endografting is a safe and viable option for the repair of descending thoracic aneurysms and other aortic pathologies. We have found it to be less invasive, even in conjunction with preoperative debranching procedures, with a shorter recovery time, decreased perioperative morbidity and blood loss, and decreased peri-operative mortality compared with standard open repair. PMID:18382748

  8. Coaxial Cables for Martian Extreme Temperature Environments

    NASA Technical Reports Server (NTRS)

    Ramesham, Rajeshuni; Harvey, Wayne L.; Valas, Sam; Tsai, Michael C.

    2011-01-01

    Work was conducted to validate the use of the rover external flexible coaxial cabling for space under the extreme environments to be encountered during the Mars Science Laboratory (MSL) mission. The antennas must survive all ground operations plus the nominal 670-Martian-day mission that includes summer and winter seasons of the Mars environment. Successful development of processes established coaxial cable hardware fatigue limits, which were well beyond the expected in-flight exposures. In keeping with traditional qualification philosophy, this was accomplished by subjecting flight-representative coaxial cables to temperature cycling of the same depth as expected in-flight, but for three times the expected number of in-flight thermal cycles. Insertion loss and return loss tests were performed on the coaxial cables during the thermal chamber breaks. A vector network analyzer was calibrated and operated over the operational frequency range 7.145 to 8.450 GHz. Even though some of the exposed cables function only at UHF frequencies (approximately 400 MHz), the testing was more sensitive, and extending the test range down to 400 MHz would have cost frequency resolution. The Gore flexible coaxial cables, which were the subject of these tests, proved to be robust and displayed no sign of degradation due to the 3X exposure to the punishing Mars surface operations cycles.

  9. Globalization, pharmaceutical pricing, and South African health policy: managing confrontation with U.S. firms and politicians.

    PubMed

    Bond, P

    1999-01-01

    Brewing since the advent of South African democracy in 1994 and promises of health sector transformation, an extraordinary drug war between President Nelson Mandela's African National Congress government and U.S. pharmaceutical manufacturers took on global proportions in 1998-1999. Within months of the passage of South African legislation aimed at lowering drug prices, the U.S. government quickly applied powerful pressure points to repeal a clause allowing potential importation of generic substitutes and imposition of compulsory licensing. At stake were not only local interpretations of patent law and World Trade Organization rules on Trade in Intellectual Property, but international power relations between developing countries and the pharmaceutical industry. In reviewing the ongoing debate, this article considers post-apartheid public health policy, U.S. government pressure to change the law, and pharmaceutical industry interests and links to the U.S. government, and evaluates various kinds of resistance to U.S. corporate and government behavior. The case thus raises--not for the first time--concerns about contemporary imperialism ("globalization"), the role of the profit motive as an incentive in vital pharmaceutical products, and indeed the depth of "democracy" in a country where high-bidding international drug firms have sufficient clout to embarrass Vice President Al Gore by pitting him against the life-and-death interests of millions of consumers of essential drugs in South Africa and other developing countries.

  10. International Space Station (ISS) Emergency Mask (EM) Development

    NASA Technical Reports Server (NTRS)

    Toon, Katherine P.; Hahn, Jeffrey; Fowler, Michael; Young, Kevin

    2011-01-01

    The Emergency Mask (EM) is considered a secondary response emergency Personal Protective Equipment (PPE) designed to provide respiratory protection to the International Space Station (ISS) crewmembers in response to a post-fire event or ammonia leak. The EM is planned to be delivered to ISS in 2012 to replace the current air purifying respirator (APR) onboard ISS called the Ammonia Respirator (AR). The EM is a one ]size ]fits ]all model designed to fit any size crewmember, unlike the APR on ISS, and uses either two Fire Cartridges (FCs) or two Commercial Off-the-Shelf (COTS) 3M(Trademark). Ammonia Cartridges (ACs) to provide the crew with a minimum of 8 hours of respiratory protection with appropriate cartridge swap ]out. The EM is designed for a single exposure event, for either post ]fire or ammonia, and is a passive device that cannot help crewmembers who cannot breathe on their own. The EM fs primary and only seal is around the wearer fs neck to prevent a crewmember from inhaling contaminants. During the development of the ISS Emergency Mask, several design challenges were faced that focused around manufacturing a leak free mask. The description of those challenges are broadly discussed but focuses on one key design challenge area: bonding EPDM gasket material to Gore(Registered Trademark) fabric hood.

  11. New U/Th ages for Pleistocene megafauna deposits of southeastern Queensland, Australia

    NASA Astrophysics Data System (ADS)

    Price, Gilbert J.; Zhao, Jian-xin; Feng, Yue-xing; Hocknull, Scott A.

    2009-02-01

    Arguments over the extinction of Pleistocene megafauna have become particularly polarised in recent years. Causes for the extinctions are widely debated with climate change, human hunting and/or habitat modification, or a combination of those factors, being the dominant hypotheses. However, a lack of a spatially constrained chronology for many megafauna renders most hypotheses difficult to test. Here, we present several new U/Th dates for a series of previously undated, megafauna-bearing localities from southeastern Queensland, Australia. The sites were previously used to argue for or against various megafauna extinction hypotheses, and are the type localities for two now-extinct Pleistocene marsupials (including the giant koala, Phascolarctos stirtoni). The new dating allows the deposits to be placed in a spatially- and temporally constrained context relevant to the understanding of Australian megafaunal extinctions. The results indicate that The Joint (Texas Caves) megafaunal assemblage is middle Pleistocene or older (>292 ky); the Cement Mills (Gore) megafaunal assemblage is late Pleistocene or older (>53 ky); and the Russenden Cave Bone Chamber (Texas Caves) megafaunal assemblage is late Pleistocene (˜55 ky). Importantly, the new results broadly show that the sites date prior to the hypothesised megafaunal extinction 'window' (i.e., ˜30-50 ky), and therefore, cannot be used to argue exclusively for or against human/climate change extinction models, without first exploring their palaeoecological significance on wider temporal and spatial scales.

  12. [Bacteriuria and Symptomatic Urinary Tract Infections during Antimicrobial Prophylaxis in Patients with Short-Term Urinary Catheters - Prospective Randomised Study in Patients after Joint Replacement Surgery].

    PubMed

    Dejmek, M; Kučera, T; Ryšková, L; Čermáková, E; Šponer, P

    2017-01-01

    PURPOSE OF THE STUDY A very serious complication following joint replacement surgery is periprosthetic joint infection that can be caused by a urinary tract infection. Insertion of an indwelling urinary catheter constitutes a risk factor that may result in urinary tract infections. The aim of this prospective randomised study was to compare the occurrence of significant bacteriuria and symptomatic urinary tract infections during antibiotic prophylaxis at the time of removal of an indwelling urinary catheter by cotrimoxazole in two doses and with no administration of antibiotics. We also monitored the incidence of potential periprosthetic infection following the endoprosthesis implantation. The findings of preoperative urine tests were compared with the declared negative preoperative examination. MATERIAL AND METHODS The study included patients indicated for a total hip or knee replacement with a negative urine culture as a part of the preoperative testing. Where leukocyteria was detected, urine culture by mid-stream clean catch urine was obtained. The second part included patients, in whom an indwelling urinary catheter had to be inserted postoperatively for urine retention and/or monitoring of fluid balance and who were divided into two groups on a rota basis. No antibiotics were administered to the first group, whereas Cotrimoxazol 960 mg tablets p.o. was administered to the second group, 14 and 2 hours before the removal of the catheter. The urine culture test was performed 4 hours after the removal of the indwelling urinary catheter, in both the groups. The test was repeated after 14 days and a questionnaire was filled in to report urinary tract complications. Considered as significant bacteriuria by urinalysis was the laboratory finding of > 10x4 CFU/ml in case of a single pathogen or > 10x5 in case of multiple pathogens. The results were statistically processed by Fischer's exact test with the level of significance = 0.05. RESULTS In the first part of the

  13. Manufacturing Challenges and Benefits when Scaling the HIAD Stacked-Torus Aeroshell to a 15m-Class System

    NASA Technical Reports Server (NTRS)

    Swanson, Gregory; Cheatwood, Neil; Johnson, Keith; Calomino, Anthony; Gilles, Brian; Anderson, Paul; Bond, Bruce

    2016-01-01

    Over a decade of work has been conducted in the development of NASAs Hypersonic Inflatable Aerodynamic Decelerator (HIAD) deployable aeroshell technology. This effort has included multiple ground test campaigns and flight tests culminating in the HIAD projects second generation (Gen-2) aeroshell system. The HIAD project team has developed, fabricated, and tested stacked-torus inflatable structures (IS) with flexible thermal protection systems (F-TPS) ranging in diameters from 3-6m, with cone angles of 60 and 70 deg. To meet NASA and commercial near term objectives, the HIAD team must scale the current technology up to 12-15m in diameter. Therefore, the HIAD projects experience in scaling the technology has reached a critical juncture. Growing from a 6m to a 15m-class system will introduce many new structural and logistical challenges to an already complicated manufacturing process.Although the general architecture and key aspects of the HIAD design scale well to larger vehicles, details of the technology will need to be reevaluated and possibly redesigned for use in a 15m-class HIAD system. These include: layout and size of the structural webbing that transfers load throughout the IS, inflatable gas barrier design, torus diameter and braid construction, internal pressure and inflation line routing, adhesives used for coating and bonding, and F-TPS gore design and seam fabrication. The logistics of fabricating and testing the IS and the F-TPS also become more challenging with increased scale. Compared to the 6m aeroshell (the largest HIAD built to date), a 12m aeroshell has four times the cross-sectional area, and a 15m one has over six times the area. This means that fabrication and test procedures will need to be reexamined to ac-count for the sheer size and weight of the aeroshell components. This will affect a variety of steps in the manufacturing process, such as: stacking the tori during assembly, stitching the structural webbing, initial inflation of tori

  14. Manufacturing Challenges and Benefits When Scaling the HIAD Stacked-Torus Aeroshell to a 15 Meter Class System

    NASA Technical Reports Server (NTRS)

    Swanson, G. T.; Cheatwood, F. M.; Johnson, R. K.; Hughes, S. J.; Calomino, A. M.

    2016-01-01

    Over a decade of work has been conducted in the development of NASA's Hypersonic Inflatable Aerodynamic Decelerator (HIAD) deployable aeroshell technology. This effort has included multiple ground test campaigns and flight tests culminating in the HIAD project's second generation (Gen-2) aeroshell system. The HIAD project team has developed, fabricated, and tested stacked-torus inflatable structures (IS) with flexible thermal protection systems (F-TPS) ranging in diameters from 3-6 meters, with cone angles of 60 and 70 degrees. To meet NASA and commercial near-term objectives, the HIAD team must scale the current technology up to 12-15 meters in diameter. Therefore, the HIAD project's experience in scaling the technology has reached a critical juncture. Growing from a 6-meter to a 15-meter class system will introduce many new structural and logistical challenges to an already complicated manufacturing process. Although the general architecture and key aspects of the HIAD design scale well to larger vehicles, details of the technology will need to be reevaluated and possibly redesigned for use in a 15-meter-class HIAD system. These include: layout and size of the structural webbing that transfers load throughout the IS, inflatable gas barrier design, torus diameter and braid construction, internal pressure and inflation line routing, adhesives used for coating and bonding, and F-TPS gore design and seam fabrication. The logistics of fabricating and testing the IS and the F-TPS also become more challenging with increased scale. Compared to the 6-meter aeroshell (the largest HIAD built to date), a 12-meter aeroshell has four times the cross-sectional area, and a 15-meter one has over six times the area. This means that fabrication and test procedures will need to be reexamined to account for the sheer size and weight of the aeroshell components. This will affect a variety of steps in the manufacturing process, such as: stacking the tori during assembly, stitching the

  15. Manufacturing Challenges and Benefits when Scaling the HIAD Stacked-Torus Aeroshell to a 15m Class System

    NASA Technical Reports Server (NTRS)

    Cheatwood, F. McNeil; Swanson, Gregory T.; Johnson, R. Keith; Hughes, Stephen; Calomino, Anthony; Gilles, Brian; Anderson, Paul; Bond, Bruce

    2016-01-01

    Over a decade of work has been conducted in the development of NASA's Hypersonic Inflatable Aerodynamic Decelerator (HIAD) deployable aeroshell technology. This effort has included multiple ground test campaigns and flight tests culminating in the HIAD project's second generation (Gen-2) aeroshell system. The HIAD project team has developed, fabricated, and tested stacked-torus inflatable structures (IS) with flexible thermal protection systems (F-TPS) ranging in diameters from 3-6m, with cone angles of 60 and 70 deg. To meet NASA and commercial near term objectives, the HIAD team must scale the current technology up to 12-15m in diameter. The HIAD project's experience in scaling the technology has reached a critical juncture. Growing from a 6m to a 15m class system will introduce many new structural and logistical challenges to an already complicated manufacturing process. Although the general architecture and key aspects of the HIAD design scale well to larger vehicles, details of the technology will need to be reevaluated and possibly redesigned for use in a 15m-class HIAD system. These include: layout and size of the structural webbing that transfers load throughout the IS, inflatable gas barrier design, torus diameter and braid construction, internal pressure and inflation line routing, adhesives used for coating and bonding, and F-TPS gore design and seam fabrication. The logistics of fabricating and testing the IS and the F-TPS also become more challenging with increased scale. Compared to the 6m aeroshell (the largest HIAD built to date), a 12m aeroshell has four times the cross-sectional area, and a 15m one has over six times the area. This means that fabrication and test procedures will need to be reexamined to account for the sheer size and weight of the aeroshell components. This will affect a variety of steps in the manufacturing process, such as: stacking the tori during assembly, stitching the structural webbing, initial inflation of tori, and

  16. Improvement of dose calculation in radiation therapy due to metal artifact correction using the augmented likelihood image reconstruction.

    PubMed

    Ziemann, Christian; Stille, Maik; Cremers, Florian; Buzug, Thorsten M; Rades, Dirk

    2018-04-17

    Metal artifacts caused by high-density implants lead to incorrectly reconstructed Hounsfield units in computed tomography images. This can result in a loss of accuracy in dose calculation in radiation therapy. This study investigates the potential of the metal artifact reduction algorithms, Augmented Likelihood Image Reconstruction and linear interpolation, in improving dose calculation in the presence of metal artifacts. In order to simulate a pelvis with a double-sided total endoprosthesis, a polymethylmethacrylate phantom was equipped with two steel bars. Artifacts were reduced by applying the Augmented Likelihood Image Reconstruction, a linear interpolation, and a manual correction approach. Using the treatment planning system Eclipse™, identical planning target volumes for an idealized prostate as well as structures for bladder and rectum were defined in corrected and noncorrected images. Volumetric modulated arc therapy plans have been created with double arc rotations with and without avoidance sectors that mask out the prosthesis. The irradiation plans were analyzed for variations in the dose distribution and their homogeneity. Dosimetric measurements were performed using isocentric positioned ionization chambers. Irradiation plans based on images containing artifacts lead to a dose error in the isocenter of up to 8.4%. Corrections with the Augmented Likelihood Image Reconstruction reduce this dose error to 2.7%, corrections with linear interpolation to 3.2%, and manual artifact correction to 4.1%. When applying artifact correction, the dose homogeneity was slightly improved for all investigated methods. Furthermore, the calculated mean doses are higher for rectum and bladder if avoidance sectors are applied. Streaking artifacts cause an imprecise dose calculation within irradiation plans. Using a metal artifact correction algorithm, the planning accuracy can be significantly improved. Best results were accomplished using the Augmented Likelihood Image

  17. High-Tech Hip Implant for Wireless Temperature Measurements In Vivo

    PubMed Central

    Bergmann, Georg; Graichen, Friedmar; Dymke, Jörn; Rohlmann, Antonius; Duda, Georg N.; Damm, Philipp

    2012-01-01

    When walking long distances, hip prostheses heat up due to friction. The influence of articulating materials and lubricating properties of synovia on the final temperatures, as well as any potential biological consequences, are unknown. Such knowledge is essential for optimizing implant materials, identifying patients who are possibly at risk of implant loosening, and proving the concepts of current joint simulators. An instrumented hip implant with telemetric data transfer was developed to measure the implant temperatures in vivo. A clinical study with 100 patients is planned to measure the implant temperatures for different combinations of head and cup materials during walking. This study will answer the question of whether patients with synovia with poor lubricating properties may be at risk for thermally induced bone necrosis and subsequent implant failure. The study will also deliver the different friction properties of various implant materials and prove the significance of wear simulator tests. A clinically successful titanium hip endoprosthesis was modified to house the electronics inside its hollow neck. The electronics are powered by an external induction coil fixed around the joint. A temperature sensor inside the implant triggers a timer circuit, which produces an inductive pulse train with temperature-dependent intervals. This signal is detected by a giant magnetoresistive sensor fixed near the external energy coil. The implant temperature is measured with an accuracy of 0.1°C in a range between 20°C and 58°C and at a sampling rate of 2–10 Hz. This rate could be considerably increased for measuring other data, such as implant strain or vibration. The employed technique of transmitting data from inside of a closed titanium implant by low frequency magnetic pulses eliminates the need to use an electrical feedthrough and an antenna outside of the implant. It enables the design of mechanically safe and simple instrumented implants. PMID:22927973

  18. Knee arthodesis using a modular customized intramedullary nail.

    PubMed

    Letartre, R; Combes, A; Autissier, G; Bonnevialle, N; Gougeon, F

    2009-11-01

    Arthrodesis of the knee, particularly in infectious situations, can be achieved using either an external fixator or an intramedullary device. The objective of this study is to report the clinical, functional, and radiographic outcomes of a continuous series of 19 cases of knee arthrodesis using a customized modular intramedullary nailing system. The modular intramedullary nail offers a satisfactory functional result while maintaining limb length, in spite of a nonunion risk, since acting like a true endoprosthesis. In our retrospective series of 19 patients, the main source of patients were infected total knee replacements. The nail was customized from assembling a dual surface-sanded titanium component (femoral and tibial). The Lequesne Algofunctional score and the WOMAC score were recorded, as well as the length discrepancy between the lower extremities. Arthrodesis consolidation and the nail's fit in the shaft were verified on anterior-posterior (AP) and lateral radiographs. Five complications were observed: one anterior cortical break, one excessive tibial rotation, two cases of delayed union, and one nail revision due to residual nail instability. The postoperative Lequesne Algofunctional score was 13/24 and the WOMAC score 57/100. The nonunion rate was 32%. From a functional point of view, the patients who did not achieve complete union and those who did had similar scores. The subjective results were not as good in patients who did not achieve final consolidation. Modular intramedullary nailing simplifies the technique, shortens the procedure, and reduces the amount of blood loss at surgery. Our nonunion rate was high, although the functional result did not seem compromised by such nonunion. The risk of long-term implant failure was not studied and requires longer follow-up studies. Level IV therapeutic study. 2009 Published by Elsevier Masson SAS.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krokidis, Miltiadis, E-mail: mkrokidis@hotmail.com; Fanelli, Fabrizio; Orgera, Gianluigi

    The purpose of this study was to compare the clinical effectiveness of expanded polytetrafluoroethylene/fluorinated-ethylene-propylene (ePTFE/FEP)-covered stents with that of uncovered nitinol stents for the palliation of malignant jaundice caused by inoperable pancreatic head cancer. Eighty patients were enrolled in a prospective randomized study. Bare nitinol stents were used in half of the patients, and ePTFE/FEP-covered stents were used in the remaining patients. Patency, survival, complications, and mean cost were calculated in both groups. Mean patency was 166.0 {+-} 13.11 days for the bare-stent group and 234.0 {+-} 20.87 days for the covered-stent group (p = 0.007). Primary patency rates atmore » 3, 6, and 12 months were 77.5, 69.8, and 69.8% for the bare-stent group and 97.5, 92.2, and 87.6% for the covered-stent group, respectively. Mean secondary patency was 123.7 {+-} 22.5 days for the bare-stent group and 130.3 {+-} 21.4 days for the covered-stent group. Tumour ingrowth occurred exclusively in the bare-stent group in 27.5% of cases (p = 0.002). Median survival was 203.2 {+-} 11.8 days for the bare-stent group and 247.0 {+-} 20 days for the covered-stent group (p = 0.06). Complications and mean cost were similar in both groups. Regarding primary patency and ingrowth rate, ePTFE/FEP-covered stents have shown to be significantly superior to bare nitinol stents for the palliation of malignant jaundice caused by inoperable pancreatic head cancer and pose comparable cost and complications. Use of a covered stent does not significantly influence overall survival rate; nevertheless, the covered endoprosthesis seems to offer result in fewer reinterventions and better quality of patient life.« less

  20. Metal or plastic stents for preoperative biliary drainage in resectable pancreatic cancer.

    PubMed

    Tol, J A M G; van Hooft, J E; Timmer, R; Kubben, F J G M; van der Harst, E; de Hingh, I H J T; Vleggaar, F P; Molenaar, I Q; Keulemans, Y C A; Boerma, D; Bruno, M J; Schoon, E J; van der Gaag, N A; Besselink, M G H; Fockens, P; van Gulik, T M; Rauws, E A J; Busch, O R C; Gouma, D J

    2016-12-01

    In pancreatic cancer, preoperative biliary drainage (PBD) increases complications compared with surgery without PBD, demonstrated by a recent randomised controlled trial (RCT). This outcome might be related to the plastic endoprosthesis used. Metal stents may reduce the PBD-related complications risk. A prospective multicentre cohort study was performed including patients with obstructive jaundice due to pancreatic cancer, scheduled to undergo PBD before surgery. This cohort was added to the earlier RCT (ISRCTN31939699). The RCT protocol was adhered to, except PBD was performed with a fully covered self-expandable metal stent (FCSEMS). This FCSEMS cohort was compared with the RCT's plastic stent cohort. PBD-related complications were the primary outcome. Three-group comparison of overall complications including early surgery patients was performed. 53 patients underwent PBD with FCSEMS compared with 102 patients treated with plastic stents. Patients' characteristics did not differ. PBD-related complication rates were 24% in the FCSEMS group vs 46% in the plastic stent group (relative risk of plastic stent use 1.9, 95% CI 1.1 to 3.2, p=0.011). Stent-related complications (occlusion and exchange) were 6% vs 31%. Surgical complications did not differ, 40% vs 47%. Overall complication rates for the FCSEMS, plastic stent and early surgery groups were 51% vs 74% vs 39%. For PBD in pancreatic cancer, FCSEMS yield a better outcome compared with plastic stents. Although early surgery without PBD remains the treatment of choice, FCSEMS should be preferred over plastic stents whenever PBD is indicated. Dutch Trial Registry (NTR3142). Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.