Science.gov

Sample records for hidrogel steril radiasi

  1. Postpartum Sterilization

    MedlinePlus

    ... sterilization. In tubal sterilization, the fallopian tubes are closed off or removed. Tubal sterilization prevents the egg ... through the incision. The tubes are cut and closed with special thread or removed completely. The incision ...

  2. Spacecraft sterilization.

    NASA Technical Reports Server (NTRS)

    Kalfayan, S. H.

    1972-01-01

    Spacecraft sterilization is a vital factor in projects for the successful biological exploration of other planets. The microorganisms of major concern are the fungi and bacteria. Sterilization procedures are oriented toward the destruction of bacterial spores. Gaseous sterilants are examined, giving attention to formaldehyde, beta-propiolactone, ethylene oxide, and the chemistry of the bactericidal action of sterilants. Radiation has been seriously considered as another method for spacecraft sterilization. Dry heat sterilization is discussed together with the effects of ethylene oxide decontamination and dry heat sterilization on materials.

  3. Reversible Sterilization

    ERIC Educational Resources Information Center

    Largey, Gale

    1977-01-01

    Notes that difficult questions arise concerning the use of sterilization for alleged eugenic and euthenic purposes. Thus, how reversible sterilization will be used with relation to the poor, mentally ill, mentally retarded, criminals, and minors, is questioned. (Author/AM)

  4. Sterile technique

    MedlinePlus

    Sterile gloves ... water and soap A sterile kit or pad Gloves (sometimes these are in your kit) A clean, ... border around it. Throw the wrapper away. Your gloves may be separate or inside the kit. To ...

  5. Sterilization System

    NASA Technical Reports Server (NTRS)

    1990-01-01

    Cox Sterile Products, Inc.'s Rapid Heat Transfer Sterilizer employs a heat exchange process that induces rapid air movement; the air becomes the heat transfer medium, maintaining a uniform temperature of 375 degrees Fahrenheit. It features pushbutton controls for three timing cycles for different instrument loads, a six-minute cycle for standard unpackaged instruments, eight minutes for certain specialized dental/medical instruments and 12 minutes for packaged instruments which can then be stored in a drawer in sterile condition. System will stay at 375 degrees all day. Continuous operation is not expensive because of the sterilizer's very low power requirements.

  6. Sterile Neutrinos

    NASA Astrophysics Data System (ADS)

    Palazzo, Antonio

    2016-05-01

    Several anomalies recorded in short-baseline neutrino experiments suggest the possibility that the standard 3-flavor framework may be incomplete and point towards a manifestation of new physics. Light sterile neutrinos provide a credible solution to these puzzling results. Here, we present a concise review of the status of the neutrino oscillations within the 3+1 scheme, the minimal extension of the standard 3-flavor framework endowed with one sterile neutrino species. We emphasize the potential role of LBL experiments in the searches of CP violation related to sterile neutrinos and their complementarity with the SBL experiments.

  7. Sterile technique

    MedlinePlus

    ... kit) A clean, dry surface Clean paper towels Wash your hands well and keep all work surfaces ... To open a sterile pad or kit: Wash your hands with soap and running ... palms, fingers, and between your fingers thoroughly. Wash ...

  8. Tubal Sterilization

    MedlinePlus

    ... you feel after the operation depends on your general health, the type of procedure and your tolerance to ... to work after sterilization? That depends on your general health, your attitude, your job and the type of ...

  9. Sterile neutrinos

    NASA Astrophysics Data System (ADS)

    Kopp, J.; Machado, P. A. N.; Maltoni, M.; Schwetz, T.

    2016-06-01

    We characterize statistically the indications of a presence of one or more light sterile neutrinos from MiniBooNE and LSND data, together with the reactor and gallium anomalies, in the global context. The compatibility of the aforementioned signals with null results from solar, atmospheric, reactor, and accelerator experiments is evaluated. We conclude that a severe tension is present in the global fit, and therefore the addition of eV-scale sterile neutrinos does not satisfactorily explain the anomalies.

  10. Sterilizing the Poor

    ERIC Educational Resources Information Center

    Rothman, Sheila M.

    1977-01-01

    Suggests that freedom for the middle classes may mean vulnerability for the poor. The enthusiasm for sterilization may be so intense as to deprive the poor of their right not to be sterilized. (Author/AM)

  11. Apparatus Circulates Sterilizing Gas

    NASA Technical Reports Server (NTRS)

    Cross, John H.; Schwarz, Ray P.

    1991-01-01

    Apparatus circulates sterilizing gas containing ethylene oxide and chlorofluorocarbon through laboratory or medical equipment. Confines sterilizing gas, circulating it only through parts to be treated. Consists of two units. One delivers ethylene oxide/chlorofluorocarbon gas mixture and removes gas after treatment. Other warms, humidifies, and circulates gas through equipment to be treated. Process provides reliable sterilization with negligible residual toxicity from ethylene oxide. Particularly suitable for sterilization of interiors of bioreactors, heart/lung machines, dialyzers, or other equipment including complicated tubing.

  12. ISO radiation sterilization standards

    NASA Astrophysics Data System (ADS)

    Lambert, Byron J.; Hansen, Joyce M.

    1998-06-01

    This presentation provides an overview of the current status of the ISO radiation sterilization standards. The ISO standards are voluntary standards which detail both the validation and routine control of the sterilization process. ISO 11137 was approved in 1994 and published in 1995. When reviewing the standard you will note that less than 20% of the standard is devoted to requirements and the remainder is guidance on how to comply with the requirements. Future standards developments in radiation sterilization are being focused on providing additional guidance. The guidance that is currently provided in informative annexes of ISO 11137 includes: device/packaging materials, dose setting methods, and dosimeters and dose measurement, currently, there are four Technical Reports being developed to provide additional guidance: 1. AAMI Draft TIR, "Radiation Sterilization Material Qualification" 2. ISO TR 13409-1996, "Sterilization of health care products — Radiation sterilization — Substantiation of 25 kGy as a sterilization dose for small or infrequent production batches" 3. ISO Draft TR, "Sterilization of health care products — Radiation sterilization Selection of a sterilization dose for a single production batch" li]4. ISO Draft TR, "Sterilization of health care products — Radiation sterilization-Product Families, Plans for Sampling and Frequency of Dose Audits."

  13. Female Tubal Sterilization

    PubMed Central

    Rowe, Timothy C.; Pabuccu, Recai

    1986-01-01

    Tubal ligation has become the second most popular method of contraception in Canada, after oral contraception. Refinement of techniques has resulted in sterilization procedures which have minimal potential for failure and high potential for reversibility. Laparoscopic and minilaparatomy techniques allow outpatient “Band-Aid” sterilizations with less risk of complications than more destructive procedures. Laparoscopic application of tubal clips or rings is highly effective, with minimal tubal destruction. Tubal ligation following a pregnancy is more often regretted than is interval sterilization. The search continues for a satisfactory transcervical sterilization procedure. PMID:21267115

  14. Sterilization for Women and Men

    MedlinePlus

    ... are rare. Can sterilization be reversed? Sterilization is permanent birth control and is not meant to be reversible. Before ... that can fertilize a female egg. Sterilization: A permanent method of birth control. Testes: Two male organs that produce sperm and ...

  15. [Sterilization and eugenics].

    PubMed

    Shasha, Shaul M

    2011-04-01

    The term "eugenics" was coined by Francis Galton in 1883 and was defined as the science of the improvement of the human race by better breeding. "Positive eugenics" referred to methods of encouraging the "most fit" to reproduce more often, while "negative eugenics" was related to ways of discouraging or preventing the "less fit" from reproducing by birth control and sterilization. Many western countries adopted eugenics programs including Britain, Canada, Norway, Australia, Switzerland and others. In Sweden more then 62,000 "unfits" were forcibly sterilized. Many states in the U.S.A. had adopted marriage laws with eugenics criteria including forced sterilization. Approximately 64,000 individuals were sterilized. Eugenics considerations also lay behind the adoption of the Immigration Restriction Act of 1924. The Largest plan on eugenics was adopted by the Nazi regime in Germany. Hundreds of thousands of people, who were viewed as being "unfit", were forcibly sterilized by different methods: Surgical sterilization or castration with severe complications and high mortality rates. X-ray irradiation. The method was suggested by Brack, and tested by Schuman using prisoners in Block No. 10 in Auschwitz and Birkenau. Experiments were also performed by Brack on prisoners using the "window method". "Klauberg method"--injection of irritating materials into the uterus. Experiments were conducted using the plant Caladium Seguinum which was believed to have sterilization and castration properties. PMID:22164927

  16. Sterilization of space hardware.

    NASA Technical Reports Server (NTRS)

    Pflug, I. J.

    1971-01-01

    Discussion of various techniques of sterilization of space flight hardware using either destructive heating or the action of chemicals. Factors considered in the dry-heat destruction of microorganisms include the effects of microbial water content, temperature, the physicochemical properties of the microorganism and adjacent support, and nature of the surrounding gas atmosphere. Dry-heat destruction rates of microorganisms on the surface, between mated surface areas, or buried in the solid material of space vehicle hardware are reviewed, along with alternative dry-heat sterilization cycles, thermodynamic considerations, and considerations of final sterilization-process design. Discussed sterilization chemicals include ethylene oxide, formaldehyde, methyl bromide, dimethyl sulfoxide, peracetic acid, and beta-propiolactone.

  17. Sterilization by Laparoscopy

    MedlinePlus

    ... sleep-like state to prevent pain during surgery. Human Immunodeficiency Virus (HIV): A virus that attacks certain cells of the body’s immune system and causes acquired immunodeficiency syndrome (AIDS). Hysteroscopic Sterilization: ...

  18. Female Sterilization (Tubal Ligation)

    MedlinePlus

    ... when you want to have it done. Some women are sterilized right after they have a baby or an abortion, ... videos on Youtube © 1998-2016 | Center for Young Women's Health, Boston Children's Hospital. All rights reserved.

  19. Sterilization: A Review and Update.

    PubMed

    Moss, Chailee; Isley, Michelle M

    2015-12-01

    Sterilization is a frequently used method of contraception. Female sterilization is performed 3 times more frequently than male sterilization, and it can be performed immediately postpartum or as an interval procedure. Methods include mechanical occlusion, coagulation, or tubal excision. Female sterilization can be performed using an abdominal approach, or via laparoscopy or hysteroscopy. When an abdominal approach or laparoscopy is used, sterilization occurs immediately. When hysteroscopy is used, tubal occlusion occurs over time, and additional testing is needed to confirm tubal occlusion. Comprehensive counseling about sterilization should include discussion about male sterilization (vasectomy) and long-acting reversible contraceptive methods. PMID:26598311

  20. Auditing radiation sterilization facilities

    NASA Astrophysics Data System (ADS)

    Beck, Jeffrey A.

    The diversity of radiation sterilization systems available today places renewed emphasis on the need for thorough Quality Assurance audits of these facilities. Evaluating compliance with Good Manufacturing Practices is an obvious requirement, but an effective audit must also evaluate installation and performance qualification programs (validation_, and process control and monitoring procedures in detail. The present paper describes general standards that radiation sterilization operations should meet in each of these key areas, and provides basic guidance for conducting QA audits of these facilities.

  1. Hysteroscopic Tubal Sterilization

    PubMed Central

    McMartin, K

    2013-01-01

    Background Hysteroscopic tubal sterilization is a minimally invasive alternative to laparoscopic tubal ligation for women who want permanent contraception. The procedures involves non-surgical placement of permanent microinserts into both fallopian tubes. Patients must use alternative contraception for at least 3 months postprocedure until tubal occlusion is confirmed. Compared to tubal ligation, potential advantages of the hysteroscopic procedure are that it can be performed in 10 minutes in an office setting without the use of general or even local anesthesia. Objective The objective of this analysis was to determine the effectiveness and safety of hysteroscopic tubal sterilization compared with tubal ligation for permanent female sterilization. Data Sources A standard systematic literature search was conducted for studies published from January 1, 2008, until December 11, 2012. Review Methods Observational studies, randomized controlled trials (RCTs), systematic reviews and meta-analyses with 1 month or more of follow-up were examined. Outcomes included failure/pregnancy rates, adverse events, and patient satisfaction. Results No RCTs were identified. Two systematic reviews covered 22 observational studies of hysteroscopic sterilization. Only 1 (N = 93) of these 22 studies compared hysteroscopic sterilization to laparoscopic tubal ligation. Two other noncomparative case series not included in the systematic reviews were also identified. In the absence of comparative studies, data on tubal ligation were derived for this analysis from the CREST study, a large, multicentre, prospective, noncomparative observational study in the United States (GRADE low). Overall, hysteroscopic sterilization is associated with lower pregnancy rates and lower complication rates compared to tubal ligation. No deaths have been reported for hysteroscopic sterilization. Limitations A lack of long-term follow-up for hysteroscopic sterilization and a paucity of studies that directly

  2. The emergence of load-oriented sterilization.

    PubMed

    Kolstad, R A

    1994-01-01

    Achieving maximum equipment sterilization is critical. Factors that contribute to sterilization efficiency are covered, including sterilization accuracy level, chamber loading and biological indicators. PMID:8031354

  3. Karlson ozone sterilizer. Final report

    SciTech Connect

    Karlson, E.

    1984-05-07

    The authors have a functional sterilization system employing ozone as a sterilization agent. This final report covers the work that led to the first medical sterilizer using ozone as the sterilizing agent. The specifications and the final design were set by hospital operating room personnel and public safety standards. Work on kill tests using bacteria, viruses and fungi determined the necessary time and concentration of ozone necessary for sterilization. These data were used in the Karlson Ozone Sterilizer to determine the length of the steps of the operating cycle and the concentration of ozone to be used. 27 references.

  4. Light sterile neutrinos

    NASA Astrophysics Data System (ADS)

    Gariazzo, S.; Giunti, C.; Laveder, M.; Li, Y. F.; Zavanin, E. M.

    2016-03-01

    The theory and phenomenology of light sterile neutrinos at the eV mass scale is reviewed. The reactor, gallium and Liquid Scintillator Neutrino Detector anomalies are briefly described and interpreted as indications of the existence of short-baseline oscillations which require the existence of light sterile neutrinos. The global fits of short-baseline oscillation data in 3 + 1 and 3 + 2 schemes are discussed, together with the implications for β-decay and neutrinoless double-β decay. The cosmological effects of light sterile neutrinos are briefly reviewed and the implications of existing cosmological data are discussed. The review concludes with a summary of future perspectives. This review is dedicated to the memory of Hai-Wei Long, our dear friend and collaborator, who passed away on 29 May 2015. He was an exceptionally kind person and an enthusiastic physicist. We deeply miss him.

  5. Light sterile neutrinos

    NASA Astrophysics Data System (ADS)

    Gariazzo, S.; Giunti, C.; Laveder, M.; Li, Y. F.; Zavanin, E. M.

    2015-03-01

    The theory and phenomenology of light sterile neutrinos at the eV mass scale is reviewed. The reactor, gallium and Liquid Scintillator Neutrino Detector anomalies are briefly described and interpreted as indications of the existence of short-baseline oscillations which require the existence of light sterile neutrinos. The global fits of short-baseline oscillation data in 3 + 1 and 3 + 2 schemes are discussed, together with the implications for β-decay and neutrinoless double-β decay. The cosmological effects of light sterile neutrinos are briefly reviewed and the implications of existing cosmological data are discussed. The review concludes with a summary of future perspectives. This review is dedicated to the memory of Hai-Wei Long, our dear friend and collaborator, who passed away on 29 May 2015. He was an exceptionally kind person and an enthusiastic physicist. We deeply miss him.

  6. Continuous sterilization of plumbing systems

    NASA Technical Reports Server (NTRS)

    Bryan, C. J.; Moyers, C. V.; Wright, E. E., Jr.

    1979-01-01

    Continuous sterilization of plumbing, such as in hospitals, clinics, and biological testing laboratories is possible with ethylene oxide/Freon 12 (ETO/F-12) humidifier developed for sterilization of potable water systems.

  7. Sterilization surgery - making a decision

    MedlinePlus

    ... have sterilization surgery. However, some may regret the decision later. Men or women who are younger at ... the options available to you before making the decision to have a sterilization procedure.

  8. MINOS Sterile Neutrino Search

    SciTech Connect

    Koskinen, David Jason

    2009-02-01

    The Main Injector Neutrino Oscillation Search (MINOS) is a long-baseline accelerator neutrino experiment designed to measure properties of neutrino oscillation. Using a high intensity muon neutrino beam, produced by the Neutrinos at Main Injector (NuMI) complex at Fermilab, MINOS makes two measurements of neutrino interactions. The first measurement is made using the Near Detector situated at Fermilab and the second is made using the Far Detector located in the Soudan Underground laboratory in northern Minnesota. The primary goal of MINOS is to verify, and measure the properties of, neutrino oscillation between the two detectors using the v μ→ Vτ transition. A complementary measurement can be made to search for the existence of sterile neutrinos; an oft theorized, but experimentally unvalidated particle. The following thesis will show the results of a sterile neutrino search using MINOS RunI and RunII data totaling ~2.5 x 1020 protons on target. Due to the theoretical nature of sterile neutrinos, complete formalism that covers transition probabilities for the three known active states with the addition of a sterile state is also presented.

  9. Sterilization of Native Americans

    ERIC Educational Resources Information Center

    Dillingham, Brint

    1977-01-01

    The U.S. State Department's Agency for International Development (AID) is spending more than $143 million this year for population control measures in over 70 nations around the world and it is estimated that as much as $10 million was spent in one year for surgical sterilization procedures. (JC)

  10. Dark matter and sterility

    NASA Astrophysics Data System (ADS)

    Smith, Peter F.

    2014-10-01

    In reply to Louise Mayor's dark-matter flow-chart "What's the matter?" (July pp30-31), which summarized the most likely candidates for galactic dark matter, and to Jon Cartwright's feature "A fourth type of neutrino" on the possibility of "sterile" neutrinos (August pp24-28).

  11. Radiation sterilization of ketoprofen

    NASA Astrophysics Data System (ADS)

    Katušin-Ražem, Branka; Hamitouche, Katia; Maltar-Strmečki, Nadica; Kos, Karmen; Pucić, Irina; Britvić-Budicin, Smiljana; Ražem, Dušan

    2005-06-01

    Radiation sterilization of ketoprofen (KP) dry powder was investigated by selected physico-chemical methods. High-performance liquid chromatography, ultraviolet spectrophotometry, infrared spectrophotometry, differential scanning calorimetry, X-ray diffraction and electron spin resonance spectroscopy did not show any significant degradation at sterilization dose 25 kGy. To determine the nature, extent and direction of radiation-induced changes, KP was irradiated to extremely high doses, much higher than necessary to achieve sterility. The irradiated KP did not show any difference of XRD patterns up to 200 kGy; with DSC and IR some changes were detected only above 1000 and 2000 kGy, respectively; HPLC has shown about 5% destruction at 2000 kGy. Acetyl benzophenon (AcBph) was generated by irradiation with G(AcBph)=(1.6±0.1)×10 -8 mol J -1. Ames test has shown no mutagenicity of KP irradiated with 3000 kGy or of the oily mixure of radiolytic products isolated from it. Solid KP has proven to be very stable on irradiation, and irradiation has been found to be a suitable method for its sterilization.

  12. Sterility of packaged implant components.

    PubMed

    Worthington, Philip

    2005-01-01

    Several implant components in their original glass vial and peel-back packages were subjected to sterility testing to determine whether the contents remained sterile after the expiration date marked on the package had passed. The results from a university microbiology laboratory showed that the contents remained sterile for 6 to 11 years after the expiration dates. PMID:15973959

  13. 21 CFR 880.6850 - Sterilization wrap.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Sterilization wrap. 880.6850 Section 880.6850 Food... § 880.6850 Sterilization wrap. (a) Identification. A sterilization wrap (pack, sterilization wrapper... sterilized by a health care provider. It is intended to allow sterilization of the enclosed medical...

  14. 21 CFR 880.6850 - Sterilization wrap.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Sterilization wrap. 880.6850 Section 880.6850 Food... § 880.6850 Sterilization wrap. (a) Identification. A sterilization wrap (pack, sterilization wrapper... sterilized by a health care provider. It is intended to allow sterilization of the enclosed medical...

  15. 21 CFR 880.6850 - Sterilization wrap.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Sterilization wrap. 880.6850 Section 880.6850 Food... § 880.6850 Sterilization wrap. (a) Identification. A sterilization wrap (pack, sterilization wrapper... sterilized by a health care provider. It is intended to allow sterilization of the enclosed medical...

  16. 21 CFR 880.6850 - Sterilization wrap.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Sterilization wrap. 880.6850 Section 880.6850 Food... § 880.6850 Sterilization wrap. (a) Identification. A sterilization wrap (pack, sterilization wrapper... sterilized by a health care provider. It is intended to allow sterilization of the enclosed medical...

  17. 21 CFR 880.6850 - Sterilization wrap.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Sterilization wrap. 880.6850 Section 880.6850 Food... § 880.6850 Sterilization wrap. (a) Identification. A sterilization wrap (pack, sterilization wrapper... sterilized by a health care provider. It is intended to allow sterilization of the enclosed medical...

  18. Sterile neutrino anarchy

    NASA Astrophysics Data System (ADS)

    Heeck, Julian; Rodejohann, Werner

    2013-02-01

    Lepton mixing, which requires physics beyond the Standard Model, is surprisingly compatible with a minimal, symmetryless and unbiased approach, called anarchy. This contrasts with highly involved flavor symmetry models. On the other hand, hints for light sterile neutrinos have emerged from a variety of independent experiments and observations. If confirmed, their existence would represent a groundbreaking discovery, calling for a theoretical interpretation. We discuss anarchy in the two-neutrino eV-scale seesaw framework. The distributions of mixing angles and masses according to anarchy are in agreement with global fits for the active and sterile neutrino parameters. Our minimal and economical scenario predicts the absence of neutrinoless double beta decay and one vanishing neutrino mass, and can therefore be tested in future experiments.

  19. Immediate Sterility after Vasectomy

    PubMed Central

    Hay, D. Urquhart

    1973-01-01

    A 2·5-ml injection of 1/1,000 solution of euflavine given down each vas during vasectomy for sterilization will destroy all sperms within the semen and eliminate the necessity for examining two consecutive specimens of semen for azoospermia after the operation. No local inflammatory response has been observed in the seminal vesicles or prostate of 81 consecutive patients in whom the method has been used. PMID:4730187

  20. Sterilization by oxygen plasma

    NASA Astrophysics Data System (ADS)

    Moreira, Adir José; Mansano, Ronaldo Domingues; Andreoli Pinto, Terezinha de Jesus; Ruas, Ronaldo; Zambon, Luis da Silva; da Silva, Mônica Valero; Verdonck, Patrick Bernard

    2004-07-01

    The use of polymeric medical devices has stimulated the development of new sterilization methods. The traditional techniques rely on ethylene oxide, but there are many questions concerning the carcinogenic properties of the ethylene oxide residues adsorbed on the materials after processing. Another common technique is the gamma irradiation process, but it is costly, its safe operation requires an isolated site and it also affects the bulk properties of the polymers. The use of a gas plasma is an elegant alternative sterilization technique. The plasma promotes an efficient inactivation of the micro-organisms, minimises the damage to the materials and presents very little danger for personnel and the environment. Pure oxygen reactive ion etching type of plasmas were applied to inactivate a biologic indicator, the Bacillus stearothermophilus, to confirm the efficiency of this process. The sterilization processes took a short time, in a few minutes the mortality was complete. In situ analysis of the micro-organisms' inactivating time was possible using emission spectrophotometry. The increase in the intensity of the 777.5 nm oxygen line shows the end of the oxidation of the biologic materials. The results were also observed and corroborated by scanning electron microscopy.

  1. [Sterilization of women].

    PubMed

    Tandberg, A

    1988-01-30

    The records of 209 women sterilized in the Lillehammer (Norway) county hospital during the period 1980-82 were examined for age, residence, parity, method of operation, induced abortions and frequency of complications. The patients were sent a questionnaire 6 months after the operation and were asked about how long they had felt unable to work after the operation, whether they regretted the operation, and whether they were satisfied with the cosmetic results. 96% of the patients returned the questionnaires. On the average the women had had 2.4 children at the time of sterilization. Those who had received induced abortions at the same time had 2.5 children. Women resident in the city had 2.1 children, those in the country had 2.4 children. None had 6 children. 20% had received abortion simultaneously. Aside from 1 patient who had transitory paresis in the left arm due to faulty padding in a shoulder support, there were no complications noted in the material. 2 patients regretted the operation. Neither of them had had simultaneous abortion. 1 of these had 1 child. Advised to be sterilized because of severe preeclampsia in her 1st pregnancy, she desired more children. The other, who had 4 children, gave decreased libido as the cause for her regret. Of the 177 who had had laparoscopy, only 6 patients (3.5%) said that they were dissatisfied with the appearance of the scar. PMID:3353913

  2. Hysteroscopic Tubal Sterilization

    PubMed Central

    2013-01-01

    Background Hysteroscopic sterilization is a minimally invasive alternative to laparoscopic tubal ligation for women who want permanent contraception. In contrast to the laparoscopic technique, a hysteroscope is used to pass permanent microinserts through the cervix and place them in the fallopian tubes. This procedure does not require local or general anesthesia and can be performed in an office setting. Objectives The objective of this analysis was to determine, based on published literature, the cost-effectiveness of hysteroscopic tubal sterilization (HS) compared with laparoscopic tubal ligation (LS) for permanent female sterilization. Data Sources A systematic literature search was conducted for studies published between January 1, 2008, and December 11, 2012. Review Methods Potentially relevant studies were identified based on the title and abstract. Cost-utility analyses (studies that report outcomes in terms of costs and quality-adjusted life-years) were prioritized for inclusion. When not available, cost-effectiveness, cost-benefit, and cost-consequence analyses were considered. Costing studies were considered in the absence of all other analyses. Results A total of 33 abstracts were identified. Three cost analyses were included. A retrospective chart review from Canada found that HS was $111 less costly than LS; a prospective activity-based cost management study from Italy reported that it was €337 less costly than LS; and the results of an American decision model showed that HS was $1,178 less costly than LS. Limitations All studies had limited applicability to the Ontario health care system due to differences in setting, resource use, and costs. Conclusions Three cost analyses found that, although the HS procedure was more expensive due to the cost of the microinserts, HS was less costly than LS overall due to the shorter recovery time required. Plain Language Summary Hysteroscopic sterilization is a minimally invasive alternative to conventional tubal

  3. Effectiveness of dental office instrument sterilization procedures.

    PubMed

    Hastreiter, R J; Molinari, J A; Falken, M C; Roesch, M H; Gleason, M J; Merchant, V A

    1991-10-01

    To evaluate instrument sterilization procedures in Minnesota, biological indicators were used to monitor 406 sterilizers in 381 dental offices. Findings suggest a general improvement in instrument performance over that of a decade ago, but sterilization failure rates are still too high. Sterilizer operator errors are a major cause of sterilization failures. BIs are useful in monitoring sterilization performance only when sterilization procedures are performed consistently and competently by well-trained staff using adequately maintained equipment. PMID:1660501

  4. Sterilization in the United States

    PubMed Central

    Bartz, Deborah; Greenberg, James A

    2008-01-01

    Unintended pregnancies are expensive for patients and for society in terms of medical costs, the cost of caring for more children, and the cost to personal and professional goals. Sterilization is the most common contraceptive method utilized by couples in the United States. Given technological advances over the past few decades, male and female surgical sterilization has become a safe, convenient, easy, and highly effective birth control method for the long term. This article reviews current male and female sterilization options. PMID:18701927

  5. Bioequivalent chemical steam sterilization indicators.

    PubMed

    Hirsch, A; Manne, S

    1984-01-01

    Biological indicators used to monitor steam sterilization cycles have two major shortcomings--the incubation period needed to determine if sterilization was accomplished, and the reliance on test packs for gathering information in each load. Chemical indicators do not suffer from these shortcomings. Chemical indicators can respond to time, temperature, and steam parameters to thus parallel the BI reaction. Nine commercially available chemical indicators and four biological indicators were evaluated under the conditions of dry heat, in a biological indicator-evaluator resistometer vessel, and in a hospital sterilizer. The results indicate that wider use of integrated chemical steam sterilization indicators is recommended. PMID:6493101

  6. New disinfection and sterilization methods.

    PubMed Central

    Rutala, W. A.; Weber, D. J.

    2001-01-01

    New disinfection methods include a persistent antimicrobial coating that can be applied to inanimate and animate objects (Surfacine), a high-level disinfectant with reduced exposure time (ortho-phthalaldehyde), and an antimicrobial agent that can be applied to animate and inanimate objects (superoxidized water). New sterilization methods include a chemical sterilization process for endoscopes that integrates cleaning (Endoclens), a rapid (4-hour) readout biological indicator for ethylene oxide sterilization (Attest), and a hydrogen peroxide plasma sterilizer that has a shorter cycle time and improved efficacy (Sterrad 50). PMID:11294738

  7. Electrolytic silver ion cell sterilizes water supply

    NASA Technical Reports Server (NTRS)

    Albright, C. F.; Gillerman, J. B.

    1968-01-01

    Electrolytic water sterilizer controls microbial contamination in manned spacecraft. Individual sterilizer cells are self-contained and require no external power or control. The sterilizer generates silver ions which do not impart an unpleasant taste to water.

  8. Sterilization of Extracted Human Teeth.

    ERIC Educational Resources Information Center

    Pantera, Eugene A., Jr.; Schuster, George S.

    1990-01-01

    At present, there is no specific recommendation for sterilization of extracted human teeth used in dental technique courses. The purpose of this study was to determine whether autoclaving would be effective in the sterilization of extracted teeth without compromising the characteristics that make their use in clinical simulations desirable. (MLW)

  9. The sterilization of endodontic hand files.

    PubMed

    Hurtt, C A; Rossman, L E

    1996-06-01

    Several different methods of file sterilization were analyzed to determine the best method of providing complete file sterility, including the metal shaft and plastic handle. Six test groups of 15 files were studied using Bacillus stearothermophilus as the test organism. Groups were "sterilized" by glutaraldehyde immersion, steam autoclaving, and various techniques of salt sterilization. Only proper steam autoclaving reliably produced completely sterile instruments. Salt sterilization and glutaraldehyde solutions may not be adequate sterilization methods for endodontic hand files and should not be relied on to provide completely sterile instruments. PMID:8934994

  10. [Sterility in medieval noblemen].

    PubMed

    van Eickels, Klaus

    2009-01-01

    The social competence of the medieval nobleman was closely associated with his male sense of honour. One essential aspect of his masculinity was the ability to produce progeny. The childlessness of a good ruler needed special justification, the childlessness of a bad ruler was seen as God's punishment. In terms of canon law, the inability to procreate was irrelevant as long as the marriage could be consummated. Considering the importance of the procreative capacity and its symbolic significance one must ask to what extent it was possible to ascertain sterility in the Middle Ages. In the case of noblemen one can assume that they could obtain certainty about their fertility through their premarital and extramarital intercourse. This might explain why some rulers and nobles accepted a childless marriage without deeming it necessary to take another wife (or plan their itinerary in a way that enabled them to produce progeny). PMID:20506725

  11. Conditional sterility in plants

    DOEpatents

    Meagher, Richard B.; McKinney, Elizabeth; Kim, Tehryung

    2010-02-23

    The present disclosure provides methods, recombinant DNA molecules, recombinant host cells containing the DNA molecules, and transgenic plant cells, plant tissue and plants which contain and express at least one antisense or interference RNA specific for a thiamine biosynthetic coding sequence or a thiamine binding protein or a thiamine-degrading protein, wherein the RNA or thiamine binding protein is expressed under the regulatory control of a transcription regulatory sequence which directs expression in male and/or female reproductive tissue. These transgenic plants are conditionally sterile; i.e., they are fertile only in the presence of exogenous thiamine. Such plants are especially appropriate for use in the seed industry or in the environment, for example, for use in revegetation of contaminated soils or phytoremediation, especially when those transgenic plants also contain and express one or more chimeric genes which confer resistance to contaminants.

  12. Effectiveness of salt versus glass bead sterilizers.

    PubMed

    Haddad, A J; Girard, B; Bouclin, R; Valois, M; Landry, R G

    1997-06-01

    Microorganisms can be removed from dental instruments by various methods, including treatment in salt and glass bead sterilizers. However, no rigorous, controlled, in vivo or in vitro studies have been performed to verify the respective efficiencies of these methods. The goals of this study were to determine if the positioning of instruments at the centre or edge of a salt sterilizer results in differential sterilization effectiveness, and to compare the effectiveness of salt sterilizers relative to glass bead sterilizers. Autoclaved number 60 reamers were contaminated by plunging them to the handle in a commercial Bacillus stearothermophilus spore suspension. They were then sterilized for different periods of time and at different positions in the sterilizers. Each experiment included positive and negative controls. The results showed that better sterilization is achieved at the edge of the chamber than at the centre, and that salt sterilizers are more effective than glass bead sterilizers for a given period of time (15 seconds) in the sterilizer. PMID:9203778

  13. Pain Associated With Hysteroscopic Sterilization

    PubMed Central

    Levy, Jenna; Childers, Meredith E.

    2007-01-01

    Background and Objectives: The safety and efficacy of female hysteroscopic sterilization using the Essure system has been well documented. Given the marked differences in the execution of hysteroscopic and laparoscopic sterilization, the objective of this study was to assess the experience of pain postprocedure between the 2. Secondary end-points included postoperative pain medication, time to return to normal activities, postprocedure bleeding, and patient satisfaction. Methods: Twenty cases each of laparoscopic sterilization (LS) and hysteroscopic sterilization (HS) were performed. Patients were surveyed regarding their experience of pain immediately postoperatively, 1 week, and 4 weeks post-procedure. Results: The average pain score immediately postprocedure was significantly lower among HS patients than among LS patients (t=−8.17, P<.0001). One-week post-procedure, none of the patients in the HS group reported any pain, while the average pain score among the LS patients was 2.65 (t =−9.67, P<.0001). Four weeks post-procedure, women in the HS group continued to report no pain, 35% of the LS group continued to report some pain (t=−3.04, P=.004). Conclusions: Hysteroscopic sterilization offers a minimally invasive, less painful, equally efficacious modality for sterilization than laparoscopic sterilization and should be available to all women seeking permanent birth control. PMID:17651558

  14. [Sterilization: necessity or genocide?].

    PubMed

    Muraro, R M

    1991-01-01

    Recent warnings by the UN Fund for Population Activities about the rapid growth of the world population and the overwhelming role in it played by impoverished women in developing countries are of interest to all women in Latin America. According to the document, Third World Women require drastic improvements in their socioeconomic positions in order to achieve reductions in their family sizes and avoid an increase in the world population from 5 billion at present to 10 billion in 2025, which would be a disaster for the planet. The document states that much of the environmental damage that would occur would be attributable to the combination of poverty and rapid population increase. If the proportion of the world's women using contraceptives increases from the current 45% to 58% by the year 2000, the world population in 2025 will be 8.5 billion. The document recommends that the amount of money invested in family planning be greatly increased by 2000 in order to make possible increased use of family planning. It appears, however, that much of the funding for family planning is under the control of private organizations and is used to serve the interests of foreign countries. The 2 principal private family planning organizations in Brazil, for example, received 18.2 million US dollars between 1978--84, which were used largely to finance a campaign of mass sterilization. Brazil's rate of population growth, which was 2.1% in 1980-85 and 1.8% in 1990, is expected to drop to 1.6% in 1995. With the decline in the rate of growth, the population will be 170 million in 2000 instead of the 220 million projected using data from the 1970s. A much higher proportion of fertile-aged women in Brazil is sterilized than in the US or Europe . Closer examination of the premises behind family planning policies shows them to be questionable. The premise that population density affects the environment is questionable; Japan, West Germany, and Holland have some of the highest population

  15. 21 CFR 880.6880 - Steam sterilizer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Steam sterilizer. 880.6880 Section 880.6880 Food... § 880.6880 Steam sterilizer. (a) Identification. A steam sterilizer (autoclave) is a device that is intended for use by a health care provider to sterilize medical products by means of pressurized steam....

  16. 21 CFR 880.6880 - Steam sterilizer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Steam sterilizer. 880.6880 Section 880.6880 Food... § 880.6880 Steam sterilizer. (a) Identification. A steam sterilizer (autoclave) is a device that is intended for use by a health care provider to sterilize medical products by means of pressurized steam....

  17. 21 CFR 880.6880 - Steam sterilizer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Steam sterilizer. 880.6880 Section 880.6880 Food... § 880.6880 Steam sterilizer. (a) Identification. A steam sterilizer (autoclave) is a device that is intended for use by a health care provider to sterilize medical products by means of pressurized steam....

  18. 21 CFR 880.6880 - Steam sterilizer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Steam sterilizer. 880.6880 Section 880.6880 Food... § 880.6880 Steam sterilizer. (a) Identification. A steam sterilizer (autoclave) is a device that is intended for use by a health care provider to sterilize medical products by means of pressurized steam....

  19. 21 CFR 880.6880 - Steam sterilizer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Steam sterilizer. 880.6880 Section 880.6880 Food... § 880.6880 Steam sterilizer. (a) Identification. A steam sterilizer (autoclave) is a device that is intended for use by a health care provider to sterilize medical products by means of pressurized steam....

  20. Sterilization surgery - making a decision

    MedlinePlus

    ... can sometimes be reversed, both must be considered permanent forms of birth control. When deciding if you want to have a ... other options for preventing pregnancy that are not permanent. Talk ... before making the decision to have a sterilization procedure.

  1. [Sterilization of mentally retarded women].

    PubMed

    Heidenreich, W; Petersen, P; Schneider, J

    1982-07-01

    Seven mentally retarded women were sterilized in the Department of Obstetrics and Gynaecology of Medical School Hannover between 1.6.74 and 1.6.81. The decision to operate proceeded only after careful consideration by the director of the clinic. Each case was documented with proof that improvement of the mental situation was unprobable and that sterilization seemed highly desirable. In spite of strong reservation the sterilization of a mentally retarded may medically and ethically be justified in exceptional cases. The operation seems possible by the following: The sterilization may only be performed if the patient does not obviously refuse it. Diagnosis and prognosis of the mental handicap must undoubtedly be proven. If the patient cannot judge the consequence of the operation the legal guardian must decide for her. The court must consent in these cases. Regarding legal theory the decision by the guardian is an open question. PMID:6922080

  2. Food irradiation and sterilization

    NASA Astrophysics Data System (ADS)

    Josephson, Edward S.

    Radiation sterilization of food (radappertization) requires exposing food in sealed containers to ionizing radiation at absorbed doses high enough (25-70 kGy) to kill all organisms of food spoilage and public health significance. Radappertization is analogous to thermal canning is achieving shelf stability (long term storage without refrigeration). Except for dry products in which autolysis is negligible, the radappertization process also requires that the food be heated to an internal temperature of 70-80°C (bacon to 53°C) to inactivate autolytic enzymes which catalyze spoilage during storage without refrigeration. To minimize the occurence of irradiation induced off-flavors and odors, undesirable color changes, and textural and nutritional losses from exposure to the high doses required for radappertization, the foods are vacuum sealed and irradiated frozen (-40°C to -20°C). Radappertozed foods have the characteristic of fresh foods prepared for eating. Radappertization can substitute in whole or in part for some chemical food additives such as ethylene oxide and nitrites which are either toxic, carcinogenic, mutagenic, or teratogenic. After 27 years of testing for "wholesomeness" (safety for consumption) of radappertized foods, no confirmed evidence has been obtained of any adverse effecys of radappertization on the "wholesomeness" characteristics of these foods.

  3. Voluntary sterilization in North Tyneside.

    PubMed

    Carnegie-Smith, K

    1984-04-01

    Since 1975, sterilization operations, on both men and women have been performed with increasing frequency within the National Health Service in the North Tyneside Area in northeast England. A prospective study was undertaken to discover some of the reasons why healthy young men and women chose surgical sterilization rather than use the established reversible methods of family planning available to them. The study examined some of the characteristics of those requesting sterilization, attempted to understand why they did so at that particular time, and assessed the patient-perceived morbidity resulting from this elective procedure. The study population included all individuals referred for consultation following the patient's request for voluntary sterilization by vasectomy or occlusive tubal surgery, during the period of 1 year (August 1, 1980-July 31, 1981). Women sterilized in association with a pregnancy outcome were not included in the study. Data on pregnancies and sterilizations in North Tyneside demonstrate a rapid increase in requests for vasectomy after 1975. Patients requesting sterilization were admitted to the study during the initial out-patient appointment with their surgeon. Couples seeking sterilization show similar age range for men (mean 34.2) and women (33.1). The proportion of patients who were not married at the time of the operation is perhaps a reflection of doctors' increasing willingness to perform sterilizations on the unmarried, and of individuals to seek such surgery in a committed manner. The increasing tendency for requests to be received from people still in their early 20s is seen as a problem. Data indicates that married people who request the operation at an early age are also those who were married under age 21, started a family immediately and with a 25% divorce rate. At the other end of the age range, couples who ahve been sucessfully using oral contraceptives have become concerned about its safety, especially after age 35. Data

  4. Radiation sterilization of skin allograft

    NASA Astrophysics Data System (ADS)

    Kairiyama, E.; Horak, C.; Spinosa, M.; Pachado, J.; Schwint, O.

    2009-07-01

    In the treatment of burns or accidental loss of skin, cadaveric skin allografts provide an alternative to temporarily cover a wounded area. The skin bank facility is indispensable for burn care. The first human skin bank was established in Argentina in 1989; later, 3 more banks were established. A careful donor selection is carried out according to the national regulation in order to prevent transmissible diseases. As cadaveric human skin is naturally highly contaminated, a final sterilization is necessary to reach a sterility assurance level (SAL) of 10 -6. The sterilization dose for 106 batches of processed human skin was determined on the basis of the Code of Practice for the Radiation Sterilization of Tissue Allografts: Requirements for Validation and Routine Control (2004) and ISO 11137-2 (2006). They ranged from 17.6 to 33.4 kGy for bioburdens of >10-162.700 CFU/100 cm 2. The presence of Gram negative bacteria was checked for each produced batch. From the analysis of the experimental results, it was observed that the bioburden range was very wide and consequently the estimated sterilization doses too. If this is the case, the determination of a tissue-specific dose per production batch is necessary to achieve a specified requirement of SAL. Otherwise if the dose of 25 kGy is preselected, a standardized method for substantiation of this dose should be done to confirm the radiation sterilization process.

  5. Neutrino Oscillations With Two Sterile Neutrinos

    NASA Astrophysics Data System (ADS)

    Kisslinger, Leonard S.

    2016-06-01

    This work estimates the probability of μ to e neutrino oscillation with two sterile neutrinos using a 5×5 U-matrix, an extension of the previous estimate with one sterile neutrino and a 4×4 U-matrix. The sterile neutrino-active neutrino mass differences and the mixing angles of the two sterile neutrinos with the three active neutrinos are taken from recent publications, and the oscillation probability for one sterile neutrino is compared to the previous estimate.

  6. Genomic Networks of Hybrid Sterility

    PubMed Central

    Turner, Leslie M.; White, Michael A.; Tautz, Diethard; Payseur, Bret A.

    2014-01-01

    Hybrid dysfunction, a common feature of reproductive barriers between species, is often caused by negative epistasis between loci (“Dobzhansky-Muller incompatibilities”). The nature and complexity of hybrid incompatibilities remain poorly understood because identifying interacting loci that affect complex phenotypes is difficult. With subspecies in the early stages of speciation, an array of genetic tools, and detailed knowledge of reproductive biology, house mice (Mus musculus) provide a model system for dissecting hybrid incompatibilities. Male hybrids between M. musculus subspecies often show reduced fertility. Previous studies identified loci and several X chromosome-autosome interactions that contribute to sterility. To characterize the genetic basis of hybrid sterility in detail, we used a systems genetics approach, integrating mapping of gene expression traits with sterility phenotypes and QTL. We measured genome-wide testis expression in 305 male F2s from a cross between wild-derived inbred strains of M. musculus musculus and M. m. domesticus. We identified several thousand cis- and trans-acting QTL contributing to expression variation (eQTL). Many trans eQTL cluster into eleven ‘hotspots,’ seven of which co-localize with QTL for sterility phenotypes identified in the cross. The number and clustering of trans eQTL—but not cis eQTL—were substantially lower when mapping was restricted to a ‘fertile’ subset of mice, providing evidence that trans eQTL hotspots are related to sterility. Functional annotation of transcripts with eQTL provides insights into the biological processes disrupted by sterility loci and guides prioritization of candidate genes. Using a conditional mapping approach, we identified eQTL dependent on interactions between loci, revealing a complex system of epistasis. Our results illuminate established patterns, including the role of the X chromosome in hybrid sterility. The integrated mapping approach we employed is

  7. Bacterial Sterilization Using Cavitating Jet

    NASA Astrophysics Data System (ADS)

    Azuma, Yohei; Kato, Hiroharu; Usami, Ron; Fukushima, Tadamasa

    In this paper, a new sterilization method using cavitating flow is presented. Water with bacteria was pressurized up to 105 MPa and flushed out through two very small nozzles 0.1-0.31 mm in diameter, where a cavitating jet was generated containing bubbles that collapsed downstream. First, the effects of jet velocity and cavitation number on the sterilization rate of Escherichia coli JCM1649T (E. coli) were examined. The sterilization rate increased with jet velocity. The rate was proportional to the 3rd power of the velocity. All the E. coli cells were killed by three successive treatments at V=355.7 m/s and cavitation number σ=0.154. The sterilization rate has a peak depending on cavitation number at the low-jet-velocity region of less than 300 m/s. An experiment was also performed to compare two types of bacteria, E. coli, as typical Gram-negative bacteria and Bacillus subtilis JCM1465T (B. subtilis), as typical Gram-positive bacteria. Additional tests were performed using Pseudomonas putida JCM13063T, Gram-negative bacteria and Bacillus halodurans JCTM9153, Gram-positive bacteria. The sterilization rate of the Gram-positive bacteria was much lower than that of the Gram-negative bacteria under the same experimental conditions. Gram-positive bacteria have a thicker peptidoglycan layer than Gram-negative bacteria. This may be the reason why B. subtilis is more resistant to the mechanical stress caused by cavitating flow.

  8. [Psychosexual implications of female sterilization].

    PubMed

    Grio, R; Fusi, D; Corsello, F P; Canestrelli, M; Abbondanza, M; Arrichiello, G; Marchino, G L

    1991-12-01

    According to data of the Italian Association for Demographic Education, from 1978 to 1991 a total of 16,000 sterilizations were carried out in patients with an average age of 36 years. There was an increasing frequency of anxiety, depression, and lack of satisfaction with sexual life, and deterioration of marital life as the consequence of the operations. Psychological improvement has been reported in only a few cases. Hysterectomy, mastectomy, abortion, and sterilization produce profound psychological effects in women. The ideal candidate for such intervention should be fully aware of the choice and be well informed about the reproductive system, and aged over 30 with at least 2 children in a stable marital relationship. A 1973 review of 80 different studies carried out in 12 different countries reported that 82% of women benefited from the operation. In a study of 180 patients in Glasgow, Scotland, psychosexual disorders were found, in only 3.6%. In a 1975 report, postoperative psychiatric disturbances in sexual life were recorded in 2% of 98 women. Another study of 94 women who were sterilized did not find any medical or psychological problems but did find patients who were completely satisfied 2 years later. In a study of 50 patients who underwent surgical sterilization by the Pomeroy technique during cesarean section, sexual behavior in the women, measured as desire, frequency of intercourse, and satisfaction, was unchanged in 47, while in 3 there were only modest variations in libido and frequency of intercourse. On the basis of these reports in the majority of cases the outcome of sterilization was favorable when assessing various gynecological problems over time. On the other hand, when the candidate is a young woman the information has to be particularly detailed and scrupulous with respect to risks and the probable irreversibility of sterilization. PMID:1819775

  9. Portable Ethylene Oxide Sterilization Chamber

    PubMed Central

    Songer, J. R.; Mathis, R. G.

    1969-01-01

    A portable ethylene oxide sterilization chamber was designed, constructed, and tested for use in the sterilization of embolectomy catheters. The unit can accommodate catheters up to 40 inches (101.6 cm) in length and can be operated for less than 4 cents per cycle. A constant concentration of 500 mg of ethylene oxide per liter of space and holding periods of 4 and 6 hr at 43 and 22 C, respectively, were adequate when tested with B. subtilis spores. The estimated cost of construction was $165.00. If temperature control is unnecessary, the cost is approximately $80.00. Images PMID:4977644

  10. Sterilization of Persons with Mental Retardation.

    ERIC Educational Resources Information Center

    Elkins, Thomas E.; Andersen, H. Frank

    1992-01-01

    This article examines the historical, legal, and ethical concerns regarding sterilization for persons with mental retardation and offers guidelines to help counsel individuals with disabilities or their families regarding decision making about sterilization. (DB)

  11. 45 CFR 96.73 - Sterilization.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ....73 Sterilization. If a State authorizes sterilization as a family planning service, it must comply with the provisions of 42 CFR Part 441, Subpart F, except that the State plan requirement under 42...

  12. 45 CFR 96.73 - Sterilization.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ....73 Sterilization. If a State authorizes sterilization as a family planning service, it must comply with the provisions of 42 CFR Part 441, Subpart F, except that the State plan requirement under 42...

  13. 45 CFR 96.73 - Sterilization.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ....73 Sterilization. If a State authorizes sterilization as a family planning service, it must comply with the provisions of 42 CFR part 441, subpart F, except that the State plan requirement under 42...

  14. 45 CFR 96.73 - Sterilization.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ....73 Sterilization. If a State authorizes sterilization as a family planning service, it must comply with the provisions of 42 CFR Part 441, Subpart F, except that the State plan requirement under 42...

  15. Low Temperature Atmospheric Pressure Plasma Sterilization Shower

    NASA Astrophysics Data System (ADS)

    Gandhiraman, R. P.; Beeler, D.; Meyyappan, M.; Khare, B. N.

    2012-10-01

    Low-temperature atmospheric pressure plasma sterilization shower to address both forward and backward biological contamination issues is presented. The molecular effects of plasma exposure required to sterilize microorganisms is also analysed.

  16. Sterilization beneath rings on dental instruments.

    PubMed

    Miller, C H; Sheldrake, M A

    1991-12-01

    This study determined the effectiveness of standard methods of instrument sterilization beneath instrument rings. Sets of three types of dental instruments were contaminated with known amounts of bacterial spores (Bacillus stearothermophilus or Bacillus subtilis). Instrument rings were placed over the contamination and the instruments processed through standard cycles in a steam autoclave, an unsaturated chemical vapor sterilizer, a standard dry heat sterilizer, an ethylene oxide gas sterilizer or a 2.0% alkaline glutaraldehyde solution. Controls consisted of spore-contaminated instruments without rings that were not processed through any sterilizing method and that were processed through each sterilizing method. All instruments and their associated rings were cultured for the presence of live spores. The results indicate that the reliability of sterilization beneath the instrument rings used is greatest if the ringed instruments are processed through a steam autoclave or an unsaturated chemical vapor sterilizer. PMID:1814351

  17. Plasma Sterilization Technology for Spacecraft Applications

    NASA Technical Reports Server (NTRS)

    Fraser, S. J.; Olson, R. L.; Leavens, W. M.

    1975-01-01

    The application of plasma gas technology to sterilization and decontamination of spacecraft components is considered. Areas investigated include: effective sterilizing ranges of four separate gases; lethal constituents of a plasma environment; effectiveness of plasma against a diverse group of microorganisms; penetrating efficiency of plasmas for sterilization; and compatibility of spacecraft materials with plasma environments. Results demonstrated that plasma gas, specifically helium plasma, is a highly effective sterilant and is compatible with spacecraft materials.

  18. Sterile pyuria: a forgotten entity

    PubMed Central

    Persad, Raj

    2015-01-01

    Sterile pyuria is a common entity. Yet there are no guidelines to address this issue. We have conducted a systematic review over 20 years and reviewed the results. Guidelines for assessment, diagnosis and management are developed based on these results. PMID:26425144

  19. Microwave powered sterile access port

    NASA Technical Reports Server (NTRS)

    Sauer, Richard L. (Inventor); Atwater, James E. (Inventor); Dahl, Roger W. (Inventor); Garmon, Frank C. (Inventor); Lunsford, Teddie D. (Inventor); Michalek, William F. (Inventor); Wheeler, Jr., Richard R. (Inventor)

    2000-01-01

    A device and method for elimination of contamination during transfer of materials either into or from bioreactors, food containers, or other microbially vulnerable systems. Using microwave power, thermal sterilizations of mating fixtures are achieved simply, reliably, and quickly by the volatilization of small quantities of water to produce superheated steam which contacts all exposed surfaces.

  20. Sterile Neutrino Search with MINOS

    SciTech Connect

    Devan, Alena V.

    2015-08-01

    MINOS, Main Injector Neutrino Oscillation Search, is a long-baseline neutrino oscillation experiment in the NuMI muon neutrino beam at the Fermi National Accelerator Laboratory in Batavia, IL. It consists of two detectors, a near detector positioned 1 km from the source of the beam and a far detector 734 km away in Minnesota. MINOS is primarily designed to observe muon neutrino disappearance resulting from three flavor oscillations. The Standard Model of Particle Physics predicts that neutrinos oscillate between three active flavors as they propagate through space. This means that a muon-type neutrino has a certain probability to later interact as a different type of neutrino. In the standard picture, the neutrino oscillation probabilities depend only on three neutrino flavors and two mass splittings, Δm2. An anomaly was observed by the LSND and MiniBooNE experiments that suggests the existence of a fourth, sterile neutrino flavor that does not interact through any of the known Standard Model interactions. Oscillations into a theoretical sterile flavor may be observed by a deficit in neutral current interactions in the MINOS detectors. A distortion in the charged current energy spectrum might also be visible if oscillations into the sterile flavor are driven by a large mass-squared difference, ms2 ~ 1 eV2. The results of the 2013 sterile neutrino search are presented here.

  1. Sterile Neutrino Search with MINOS

    NASA Astrophysics Data System (ADS)

    Devan, Alena V.

    MINOS, Main Injector Neutrino Oscillation Search, is a long-baseline neutrino oscillation experiment in the NuMI muon neutrino beam at the Fermi National Accelerator Laboratory in Batavia, IL. It consists of two detectors, a near detector positioned 1 km from the source of the beam and a far detector 734 km away in Minnesota. MINOS is primarily designed to observe muon neutrino disappearance resulting from three flavor oscillations. The Standard Model of Particle Physics predicts that neutrinos oscillate between three active flavors as they propagate through space. This means that a muon type neutrino has a certain probability to later interact as a different type of neutrino. In the standard picture, the neutrino oscillation probabilities depend only on three neutrino flavors and two mass splittings, Amt. An anomaly was observed by the LSND and MiniBooNE experiments that suggests the existence of a fourth, sterile neutrino flavor that does not interact through any of the known Standard Model interactions. Oscillations into a theoretical sterile flavor may be observed by a deficit in neutral current interactions in the MINOS detectors. A distortion in the charged current energy spectrum might also be visible if oscillations into the sterile flavor are driven by a large mass-squared difference, Delta m2s 1 eV2. The results of the 2013 sterile neutrino search are presented here.

  2. The limits of sterility assurance

    PubMed Central

    von Woedtke, Thomas; Kramer, Axel

    2008-01-01

    Sterility means the absence of all viable microorganisms including viruses. At present, a sterility assurance level (SAL) of 10–6 is generally accepted for pharmacopoeial sterilization procedures, i.e., a probability of not more than one viable microorganism in an amount of one million sterilised items of the final product. By extrapolating the reduction rates following extreme artificial initial contamination, a theoretical overall performance of the procedure of at least 12 lg increments (overkill conditions) is demanded to verify an SAL of 10–6. By comparison, other recommendations for thermal sterilization procedures demand only evidence that the difference between the initial contamination and the number of test organisms at the end of the process amount to more than six orders of magnitude. However, a practical proof of the required level of sterility assurance of 10–6 is not possible. Moreover, the attainability of this condition is fundamentally dubious, at least in non-thermal procedures. Thus, the question is discussed whether the undifferentiated adherence to the concept of sterility assurance on the basis of a single SAL of 10–6 corresponds with the safety requirements in terms of patient or user safety, costs and energy efficiency. Therefore, in terms of practical considerations, a concept of tiered SALs is recommended, analogous to the comparable and well-established categorization into “High-level disinfection”, “Intermediate-level disinfection” and “Low-level disinfection”. The determination of such tiered SALs is geared both to the intended application of the sterilized goods, as well as to the characteristics of the products and the corresponding treatment options. In the case of aseptic preparation, filling and production procedures, a mean contamination probability of 10–3 is assumed. In automated processes, lower contamination rates can be realized. In the case of the production of re-usable medical devices, a reduction of

  3. 45 CFR 96.73 - Sterilization.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ....73 Sterilization. If a State authorizes sterilization as a family planning service, it must comply with the provisions of 42 CFR Part 441, Subpart F, except that the State plan requirement under 42 CFR... 45 Public Welfare 1 2010-10-01 2010-10-01 false Sterilization. 96.73 Section 96.73 Public...

  4. Microwave Sterilization and Depyrogenation System

    NASA Technical Reports Server (NTRS)

    Akse, James R.; Dahl, Roger W.; Wheeler, Richard R., Jr.

    2009-01-01

    A fully functional, microgravity-compatible microwave sterilization and depyrogenation system (MSDS) prototype was developed that is capable of producing medical-grade water (MGW) without expendable supplies, using NASA potable water that currently is available aboard the International Space Station (ISS) and will be available for Lunar and planetary missions in the future. The microwave- based, continuous MSDS efficiently couples microwaves to a single-phase, pressurized, flowing water stream that is rapidly heated above 150 C. Under these conditions, water is rapidly sterilized. Endotoxins, significant biological toxins that originate from the cell walls of gram-negative bacteria and which represent another defining MGW requirement, are also deactivated (i.e., depyrogenated) albeit more slowly, with such deactivation representing a more difficult challenge than sterilization. Several innovations culminated in the successful MSDS prototype design. The most significant is the antenna-directed microwave heating of a water stream flowing through a microwave sterilization chamber (MSC). Novel antenna designs were developed to increase microwave transmission efficiency. These improvements resulted in greater than 95-percent absorption of incident microwaves. In addition, incorporation of recuperative heat exchangers (RHxs) in the design reduced the microwave power required to heat a water stream flowing at 15 mL/min to 170 C to only 50 W. Further improvements in energy efficiency involved the employment of a second antenna to redirect reflected microwaves back into the MSC, eliminating the need for a water load and simplifying MSDS design. A quick connect (QC) is another innovation that can be sterilized and depyrogenated at temperature, and then cooled using a unique flow design, allowing collection of MGW at atmospheric pressure and 80 C. The final innovation was the use of in-line mixers incorporated in the flow path to disrupt laminar flow and increase contact time

  5. Bisexual Hybrid Sterility in DROSOPHILA MELANOGASTER

    PubMed Central

    Colgan, D. J.; Angus, D. S.

    1978-01-01

    A new type of hybrid sterility was investigated in D. melanogaster . Matings between strain 27 males from Para Wirra, South Australia, and Canton-S females produce 70–80% fully sterile male and female progeny. Strain 27 males produce sterile progeny when crossed to females of other geographic origins, but produce fertile progeny when crossed to a second sympatric strain. The sterility is avoided by lower rearing temperatures. Heat shock and tetracycline produce no improvement in the fertility of the hybrids. Normal flies produce sterile progeny when injected with, or fed, homogenates of sterile flies. A combination of maternal and paternal factors may interact to produce sterile hybrids by inhibiting gonad development. PMID:17248832

  6. Implementing AORN recommended practices for sterilization.

    PubMed

    Graybill-D'Ercole, Patricia

    2013-05-01

    Any hospital or facility in which surgery and other invasive procedures are performed should have accommodations for cleaning, decontaminating, disinfecting, and sterilizing instruments, equipment, and other essential supplies that are used for patient procedures. Sterilization is essential to reducing or preventing the risk of surgical site infections. This is a collaborative process and should include all health care providers who handle these instruments, including perioperative nurses. The revised AORN "Recommended practices for sterilization," which became effective June 15, 2012, includes updates on sterilizing single-use items, inspecting critical items before sterilization, using low-temperature hydrogen peroxide vapor sterilization methods, and immediate use steam sterilization. This RP document is the first AORN document to be evidence rated and accepted for inclusion in the Agency for Healthcare Research and Quality National Guideline Clearinghouse. PMID:23622825

  7. Sixteen years of experience with sterilization monitoring.

    PubMed

    Molinari, J A; Gleason, M J; Merchant, V A

    1994-12-01

    Sterilization in the dental office should be monitored to ascertain proper sterilizer function. Biologic monitoring with calibrated preparations of bacterial spores is the preferred, as well as the only method that actually measures sterilization. A dental school-based sterilization monitoring service for dental practices was established in 1978 at the University of Detroit. This service has grown from 20 participating dental offices to more than 1,500. In 1993, 18,137 biologic monitoring tests were performed. The participants in the service primarily use autoclaves (70%) for heat sterilization, while unsaturated chemical-vapor sterilizers (20%) and dry-heat units (10%) are less common. This article describes the history of sterilization monitoring in dental practices from 1978 to the present through a dental school-based service. PMID:7758029

  8. [Prolactin and sterility (author's transl)].

    PubMed

    Santeler, P; Martin, J; Daxenbichler, G

    1980-07-01

    From July 1975 to December 1979 at the Univ.-Klinik für Frauenheilkunde, Innsbruck, 91 female sterile patients were examined due to hyperprolactinaemia. Since hyperprolactin presents common symptoms of different diseases, we established a differentiated clarification and therapy scheme using the guidelines of the W.H.O. and all new knowledge. After disqualification of patients with corresponding tubular sterility, we induced in 24 patients 32 pregnancies with medication or operative therapy. After birth or abortion a prolactin-caused dysfunction reappeared in the reproductive system. With a gradual prolactin increasion in the serum level, the grade of this dysfunction in the reproductive system was worsened. A reduction of the prolactin serum level to 40 ng/ml seems to be the basis for spontaneous ovulation. Present therapeutic possibilities and as a result the reversibility of this disturbance after interruption of prolactin inhibitors, we find that long-therm therapy is necessary. PMID:6933737

  9. Method of sterilization using ozone

    NASA Technical Reports Server (NTRS)

    Murphy, Oliver J. (Inventor); Hitchens, G. Duncan (Inventor)

    2002-01-01

    Methods of using ozone have been developed which sterilize instruments and medical wastes, oxidize, organics found in wastewater, clean laundry, break down contaminants in soil into a form more readily digested by microbes, kill microorganisms present in food products, and destroy toxins present in food products. The preferred methods for killing microorganism and destroying toxins use pressurized, humidified, and concentrated ozone produced by an electrochemical cell.

  10. Observation of Effectiveness of Clinical Sterilization by CASP-80A Low-Temperature Plasma Sterilizer

    NASA Astrophysics Data System (ADS)

    Li, Si; Zhang, Yangde; Liu, Weidong

    2006-09-01

    The influence on the effectiveness of sterilization by low-temperature plasma sterilizer CASP-80A was investigated so as to provide a theoretical basis for reducing medical costs and achieving ideal sterilization effectiveness. To conduct the on-site simulation test, a clinical material sterilization test and a test of the influence of organic substance were conducted, the former by using the representative of Bacillus Stearothermophilus, preparing the bacteria-contaminated carrier through polytetrafluoroethylene (PTFE) simulated hose endoscopes, and the latter by using calf serum as the influence factor of the organic substance. The results show that the CASP-80A low-temperature plasma sterilizer could achieve effective sterilization by either the short-cycle or the long-cycle sterilization method depending on different materials, apparatus, and extent of contamination. The organic substances could influence the effectiveness of sterilization by the low-temperature plasma (H2O2) sterilizer.

  11. Sterile neutrinos as dark matter

    SciTech Connect

    Dodelson, S.; Widrow, L.M. |

    1993-03-01

    The simplest model that can accommodate a viable nonbaryonic dark matter candidate is the standard electroweak theory with the addition of right-handed or sterile neutrinos. This model has been studied extensively in the context of the hot dark matter scenario. We reexamine this model and find that hot, warm, and cold dark matter are all possibilities. We focus on the case where sterile neutrinos are the dark matter. Since their only direct coupling is to left-handed or active neutrinos, the most efficient production mechanism is via neutrino oscillations. If the production rate is always less than the expansion rate, then these neutrinos will never be in thermal equilibrium. However, they may still play a significant role in the dynamics of the Universe and possibly provide the missing mass necessary for closure. We consider a single generation of neutrino fields ({nu}{sub L}, {nu}{sub R}) with a Dirac mass, {mu}, and a Majorana mass for the right-handed components only, M. For M {much_gt} {mu} we show that the number density of sterile neutrinos is proportional to {mu}{sup 2}/M so that the energy density today is independent of M. However M is crucial in determining the large scale structure of the Universe. In particular, M {approx_equal} 0.1--1.0 key leads to warm dark matter and a structure formation scenario that may have some advantages over both the standard hot and cold dark matter scenarios.

  12. Sterile neutrinos as dark matter

    SciTech Connect

    Dodelson, S. ); Widrow, L.M. . Dept. of Physics Toronto Univ., ON . Canadian Inst. for Theoretical Astrophysics)

    1993-03-01

    The simplest model that can accommodate a viable nonbaryonic dark matter candidate is the standard electroweak theory with the addition of right-handed or sterile neutrinos. This model has been studied extensively in the context of the hot dark matter scenario. We reexamine this model and find that hot, warm, and cold dark matter are all possibilities. We focus on the case where sterile neutrinos are the dark matter. Since their only direct coupling is to left-handed or active neutrinos, the most efficient production mechanism is via neutrino oscillations. If the production rate is always less than the expansion rate, then these neutrinos will never be in thermal equilibrium. However, they may still play a significant role in the dynamics of the Universe and possibly provide the missing mass necessary for closure. We consider a single generation of neutrino fields ([nu][sub L], [nu][sub R]) with a Dirac mass, [mu], and a Majorana mass for the right-handed components only, M. For M [much gt] [mu] we show that the number density of sterile neutrinos is proportional to [mu][sup 2]/M so that the energy density today is independent of M. However M is crucial in determining the large scale structure of the Universe. In particular, M [approx equal] 0.1--1.0 key leads to warm dark matter and a structure formation scenario that may have some advantages over both the standard hot and cold dark matter scenarios.

  13. Sterile Neutrinos in Cold Climates

    SciTech Connect

    Jones, Benjamin J.P.

    2015-09-01

    Measurements of neutrino oscillations at short baselines contain an intriguing set of experimental anomalies that may be suggestive of new physics such as the existence of sterile neutrinos. This three-part thesis presents research directed towards understanding these anomalies and searching for sterile neutrino oscillations. Part I contains a theoretical discussion of neutrino coherence properties. The open-quantum-system picture of neutrino beams, which allows a rigorous prediction of coherence distances for accelerator neutrinos, is presented. Validity of the standard treatment of active and sterile neutrino oscillations at short baselines is verified, and non-standard coherence loss effects at longer baselines are predicted. Part II concerns liquid argon detector development for the MicroBooNE experiment, which will search for short-baseline oscillations in the Booster Neutrino Beam at Fermilab. Topics include characterization and installation of the MicroBooNE optical system; test-stand measurements of liquid argon optical properties with dissolved impurities; optimization of wavelength-shifting coatings for liquid argon scintillation light detection; testing and deployment of high-voltage surge arrestors to protect TPC field cages; and software development for optical and TPC simulation and reconstruction. Part III presents a search for sterile neutrinos using the IceCube neutrino telescope, which has collected a large sample of atmospheric-neutrino-induced events in the 1-10 TeV energy range. Sterile neutrinos would modify the detected neutrino flux shape via MSW-resonant oscillations. Following a careful treatment of systematic uncertainties in the sample, no evidence for MSW-resonant oscillations is observed, and exclusion limits on 3+1 model parameter space are derived. Under the mixing assumptions made, the 90% confidence level exclusion limit extends to sin224 ≤ 0.02 at m2 ~ 0.3 eV2, and the LSND and Mini

  14. Plasma Sterilization: New Epoch in Medical Textiles

    NASA Astrophysics Data System (ADS)

    Senthilkumar, P.; Arun, N.; Vigneswaran, C.

    2015-04-01

    Clothing is perceived to be second skin to the human body since it is in close contact with the human skin most of the times. In hospitals, use of textile materials in different forms and sterilization of these materials is an essential requirement for preventing spread of germs. The need for appropriate disinfection and sterilization techniques is of paramount importance. There has been a continuous demand for novel sterilization techniques appropriate for use on various textile materials as the existing sterilization techniques suffer from various technical and economical drawbacks. Plasma sterilization is the alternative method, which is friendlier and more effective on the wide spectrum of prokaryotic and eukaryotic microorganisms. Basically, the main inactivation factors for cells exposed to plasma are heat, UV radiation and various reactive species. Plasma exposure can kill micro-organisms on a surface in addition to removing adsorbed monolayer of surface contaminants. Advantages of plasma surface treatment are removal of contaminants from the surface, change in the surface energy and sterilization of the surface. Plasma sterilization aims to kill and/or remove all micro-organisms which may cause infection of humans or animals, or which can cause spoilage of foods or other goods. This review paper emphasizes necessity for sterilization, essentials of sterilization, mechanism of plasma sterilization and the parameters influencing it.

  15. Radiation sterilization of new drug delivery systems

    PubMed Central

    Abuhanoğlu, Gürhan

    2014-01-01

    Radiation sterilization has now become a commonly used method for sterilization of several active ingredients in drugs or drug delivery systems containing these substances. In this context, many applications have been performed on the human products that are required to be sterile, as well as on pharmaceutical products prepared to be developed. The new drug delivery systems designed to deliver the medication to the target tissue or organ, such as microspheres, nanospheres, microemulsion, and liposomal systems, have been sterilized by gamma (γ) and beta (β) rays, and more recently, by e-beam sterilization. In this review, the sterilization of new drug delivery systems was discussed other than conventional drug delivery systems by γ irradiation. PMID:24936306

  16. Surgical Sterilization, Regret, and Race: Contemporary Patterns*

    PubMed Central

    Shreffler, Karina M.; McQuillan, Julia; Greil, Arthur L.; Johnson, David R.

    2014-01-01

    Surgical sterilization is a relatively permanent form of contraception that has been disproportionately used by Black, Hispanic, and Native American women in the United States in the past. We use a nationally representative sample of 4,609 women ages 25 to 45 to determine whether sterilization continues to be more common and consequential by race for reproductive-age women. Results indicate that Native American and Black women are more likely to be sterilized than non-Hispanic White women, and Hispanic and Native American women are more likely than non-Hispanic White women to report that their sterilization surgeries prevent them from conceiving children they want. Reasons for sterilization differ significantly by race. These findings suggest that stratified reproduction has not ended in the United States and that the patterns and consequences of sterilization continue to vary by race. PMID:25592919

  17. Locating the voices of the sterilized.

    PubMed

    Kluchin, Rebecca M

    2007-01-01

    Scholars have been studying eugenics and sterilization for years, but only recently have some begun to examine these issues from the point of view of those sterilized. This is in large part because so few records containing the voices of the sterilized exist or are accessible to scholars. This essay examines my own effort to recover the voices of women sterilized in the post-baby boom United States from the "bottom up" and includes my own experience researching and writing Fit to Be Tied?: Sterilization and Reproductive Rights in America, 1960-1984. It represents the beginning of a discussion about locating and using sources containing the voices of the sterilized and working with the limitations inherent to them. PMID:18175455

  18. Hysteroscopic Sterilization: History and Current Methods

    PubMed Central

    Greenberg, James A

    2008-01-01

    For many practicing obstetrician-gynecologists, tubal ligation was the gold standard by which female sterilization techniques were measured. Yet gynecologic surgeons have simultaneously sought to occlude the fallopian tubes transcervically to avoid discomfort and complications associated with transabdominal approaches. In this review, the history of transcervical sterilization is discussed. Past, current, and upcoming techniques are reviewed. This article focuses on interval sterilization techniques, thus removing post-vaginal and post-cesarean delivery tubal ligations from the discussion. PMID:19015762

  19. New developments in disinfection and sterilization.

    PubMed

    Wallace, Craig A

    2016-05-01

    A review of regulatory clearances for selected new sterilization and disinfection products for the period January 2012-June 2015 indicates continued leverage of established technologies for steam and low-temperature sterilization, and high-level disinfection. New products in these areas were typically modified and improved versions of existing products, with the exception of a new combination hydrogen peroxide/ozone sterilizer. Development of new low-temperature sterilization technologies to address continued evolution of complex medical devices is expected to continue. PMID:27131131

  20. Ramifications of a sterile Mars

    NASA Astrophysics Data System (ADS)

    Levin, Gilbert V.

    2011-10-01

    The seldom considered ramifications of a sterile Mars are explored. Very much is now known about the environment on Mars. Herein, the individual and collective environmental parameters are examined with particular consideration of those that might be inimical to life as we know it, or as might reasonably be assumed to be so to alien life. It is shown that no single measurement or combination of them precludes the ability of Mars to support even a wide number of terrestrial microbial species, let alone the likely greater tolerance and/or adaptability of possible alien life forms. Some yet unknown factor or combination of factors would have to be responsible for Mars' failure to generate life or to successfully harbor viable forms received from space. Since Mars is so Earth-like, the red planet's sterility could deliver a fatal blow to the growing concept of a cosmic Biologic Imperative, and would raise the daunting prospect that Earth is a unique or a very rare habitat.

  1. Review of surface steam sterilization for validation purposes.

    PubMed

    van Doornmalen, Joost; Kopinga, Klaas

    2008-03-01

    Sterilization is an essential step in the process of producing sterile medical devices. To guarantee sterility, the process of sterilization must be validated. Because there is no direct way to measure sterility, the techniques applied to validate the sterilization process are based on statistical principles. Steam sterilization is the most frequently applied sterilization method worldwide and can be validated either by indicators (chemical or biological) or physical measurements. The steam sterilization conditions are described in the literature. Starting from these conditions, criteria for the validation of steam sterilization are derived and can be described in terms of physical parameters. Physical validation of steam sterilization appears to be an adequate and efficient validation method that could be considered as an alternative for indicator validation. Moreover, physical validation can be used for effective troubleshooting in steam sterilizing processes. PMID:18313509

  2. 9 CFR 109.2 - Sterilizers.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false Sterilizers. 109.2 Section 109.2 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE VIRUSES, SERUMS, TOXINS, AND ANALOGOUS PRODUCTS; ORGANISMS AND VECTORS STERILIZATION AND PASTEURIZATION...

  3. 21 CFR 610.12 - Sterility.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... BIOLOGICAL PRODUCTS STANDARDS General Provisions § 610.12 Sterility. (a) The test. Except as provided in paragraph (h) of this section, manufacturers of biological products must perform sterility testing of each lot of each biological product's final container material or other material, as appropriate and...

  4. 21 CFR 610.12 - Sterility.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... BIOLOGICAL PRODUCTS STANDARDS General Provisions § 610.12 Sterility. (a) The test. Except as provided in paragraph (h) of this section, manufacturers of biological products must perform sterility testing of each lot of each biological product's final container material or other material, as appropriate and...

  5. 9 CFR 109.2 - Sterilizers.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Sterilizers. 109.2 Section 109.2 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE VIRUSES, SERUMS, TOXINS, AND ANALOGOUS PRODUCTS; ORGANISMS AND VECTORS STERILIZATION AND PASTEURIZATION...

  6. Eugenics and Involuntary Sterilization: 1907-2015.

    PubMed

    Reilly, Philip R

    2015-01-01

    In England during the late nineteenth century, intellectuals, especially Francis Galton, called for a variety of eugenic policies aimed at ensuring the health of the human species. In the United States, members of the Progressive movement embraced eugenic ideas, especially immigration restriction and sterilization. Indiana enacted the first eugenic sterilization law in 1907, and the US Supreme Court upheld such laws in 1927. State programs targeted institutionalized, mentally disabled women. Beginning in the late 1930s, proponents rationalized involuntary sterilization as protecting vulnerable women from unwanted pregnancy. By World War II, programs in the United States had sterilized approximately 60,000 persons. After the horrific revelations concerning Nazi eugenics (German Hereditary Health Courts approved at least 400,000 sterilization operations in less than a decade), eugenic sterilization programs in the United States declined rapidly. Simplistic eugenic thinking has faded, but coerced sterilization remains widespread, especially in China and India. In many parts of the world, involuntary sterilization is still intermittently used against minority groups. PMID:26322647

  7. 9 CFR 109.2 - Sterilizers.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 9 Animals and Animal Products 1 2013-01-01 2013-01-01 false Sterilizers. 109.2 Section 109.2 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE VIRUSES, SERUMS, TOXINS, AND ANALOGOUS PRODUCTS; ORGANISMS AND VECTORS STERILIZATION AND PASTEURIZATION...

  8. 9 CFR 109.2 - Sterilizers.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 9 Animals and Animal Products 1 2014-01-01 2014-01-01 false Sterilizers. 109.2 Section 109.2 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE VIRUSES, SERUMS, TOXINS, AND ANALOGOUS PRODUCTS; ORGANISMS AND VECTORS STERILIZATION AND PASTEURIZATION...

  9. 9 CFR 109.2 - Sterilizers.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 9 Animals and Animal Products 1 2012-01-01 2012-01-01 false Sterilizers. 109.2 Section 109.2 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE VIRUSES, SERUMS, TOXINS, AND ANALOGOUS PRODUCTS; ORGANISMS AND VECTORS STERILIZATION AND PASTEURIZATION...

  10. Monitoring dental sterilizers' effectiveness using biological indicators.

    PubMed

    Nickerson, A; Bhuta, P; Orton, G; Alvin, B

    1990-02-01

    The purpose of this study was to evaluate the effectiveness of dental office sterilizers as measured by their ability to kill bacterial spores present on biological indicator strips. The biological indicators used in this study contained two different spores, Bacillus stearothermophilus and Bacillus subtilis (Spordi, AMSCO/Medical Products). Ten spore test strips were sent to 87 dental offices; 51 sterilizers were tested. Office personnel were instructed to place four strips in the center of a normal sterilization load and process the load. The procedure was repeated on a second day. The processed strips, along with two unprocessed control strips, were returned by mail for laboratory culturing. The results indicated the overall failure rate (positive test) of sterlizers tested for both days was 51% at the culturing temperature of 37 degrees C and 33.3% at 55 degrees C. McNemar's test indicated a significant difference (p less than .03) in sterilization failures associated with the type and number of microorganisms present on the test strips. This study also showed that the more times a sterilizer was tested, the more likely a failure would occur. Overall, an alarming number of sterilizers (64.7%) were not effective in killing all the spores present on the indicator strips. When office personnel were given information for improving sterilizer performance, there was a noticeable reduction in sterilization failures following retesting. PMID:2370583

  11. Viking heat sterilization - Progress and problems

    NASA Technical Reports Server (NTRS)

    Daspit, L. P.; Cortright, E. M.; Stern, J. A.

    1974-01-01

    The Viking Mars landers to be launched in 1975 will carry experiments in biology, planetology, and atmospheric physics. A terminal dry-heat sterilization process using an inert gas was chosen to meet planetary quarantine requirements and preclude contamination of the biology experiment by terrestrial organisms. Deep sterilization is performed at the component level and terminal surface sterilization at the system level. Solutions to certain component problems relating to sterilization are discussed, involving the gyroscope, tape recorder, battery, electronic circuitry, and outgassing. Heat treatment placed special requirements on electronic packaging, including fastener preload monitoring and solder joints. Chemical and physical testing of nonmetallic materials was performed to establish data on their behavior in heat-treatment and vacuum environments. A Thermal Effects Test Model and a Proof Test Capsule were used. It is concluded that a space vehicle can be designed and fabricated to withstand heat sterilization requirements.

  12. Disinfection, sterilization, and antisepsis: An overview.

    PubMed

    Rutala, William A; Weber, David J

    2016-05-01

    All invasive procedures involve contact by a medical device or surgical instrument with a patient's sterile tissue or mucous membranes. The level of disinfection or sterilization is dependent on the intended use of the object: critical (items that contact sterile tissue such as surgical instruments), semicritical (items that contact mucous membrane such as endoscopes), and noncritical (devices that contact only intact skin such as stethoscopes) items require sterilization, high-level disinfection and low-level disinfection, respectively. Cleaning must always precede high-level disinfection and sterilization. Antiseptics are essential to infection prevention as part of a hand hygiene program as well as several other uses such as surgical hand antisepsis and pre-operative skin preparation. PMID:27131128

  13. Sterilization and contraceptive services in Catholic hospitals.

    PubMed

    O'Lane, J M

    1979-02-15

    Sterilization and contraceptive practices in United States Catholic hospitals were surveyed by anonymous mail questionnaires, obtaining a 57% response rate (340 of 598). Twenty per cent of the hospitals permitted medically indicated sterilization operations. Forty-seven per cent of those hospitals not allowing sterilization procedures reported that their medical staffs were interested in performing medically indicated sterilizations. The types of contraceptive services offered varied widely. The rhythm method was most frequently available, with oral contraceptives in second place; many hospitals did not provide any family-planning services; 13% utilized all types of contraception. The thesis is advanced that improvement in availability of sterilization and contraceptive services is a duty of hospital medical staffs. PMID:433994

  14. Vapor Hydrogen Peroxide Sterilization Certification

    NASA Astrophysics Data System (ADS)

    Chen, Fei; Chung, Shirley; Barengoltz, Jack

    For interplanetary missions landing on a planet of potential biological interest, United States NASA planetary protection currently requires that the flight system must be assembled, tested and ultimately launched with the intent of minimizing the bioload taken to and deposited on the planet. Currently the only NASA approved microbial reduction method is dry heat sterilization process. However, with utilization of such elements as highly sophisticated electronics and sensors in modern spacecraft, this process presents significant materials challenges and is thus an undesirable bioburden reduction method to design engineers. The objective of this work is to introduce vapor hydrogen peroxide (VHP) as an alternative to dry heat microbial reduction to meet planetary protection requirements. The VHP sterilization technology is widely used by the medical industry, but high doses of VHP may degrade the performance of flight hardware, or compromise material compatibility. The goal of our study is determine the minimum VHP process conditions for PP acceptable microbial reduction levels. A series of experiments were conducted using Geobacillus stearothermophilus to determine VHP process parameters that provided significant reductions in spore viability while allowing survival of sufficient spores for statistically significant enumeration. In addition to the obvious process parameters -hydrogen peroxide concentration, number of pulses, and exposure duration -the investigation also considered the possible effect of environmental pa-rameters. Temperature, relative humidity, and material substrate effects on lethality were also studied. Based on the results, a most conservative D value was recommended. This recom-mended D value was also validated using VHP "hardy" strains that were isolated from clean-rooms and environmental populations collected from spacecraft relevant areas. The efficiency of VHP at ambient condition as well as VHP material compatibility will also be

  15. Iran eases limits on sterilization.

    PubMed

    Roudi, N

    1991-03-01

    The government of Iran announced in November 1990, in an abrupt reversal of previous policies, the legislation of sterilization and its provision free-of-charge upon request, as well as the distribution of other contraceptive gratis. At the time of the Islamic Revolution in 1979 the government adopted a pronatalist policy, family planning programs were interrupted, legal ages of marriage were lowered, and barriers against polygamy were loosened. Iran had a 3.5% growth rate in 1990 and a total fertility rate of 6.3 lifetime births/woman. After the end of the war between Iran and Iraq in 1988, the population explosion became an obstacle to reconstruction. In 1950, the population numbered 14.2 million; by 1970 it had doubled to 28.4 million. In 1990, the country had 54.6 million people. According to a 1990 UN assessment the population will soar to 100 million by 2020. Over 8 million live in Tehran where overcrowding, traffic congestion, air pollution, and high living costs are the norm. the 1989 National Birth Control Policy Summary adopted targets to reduce the average number of lifetime births per woman to 4 children and natural growth rate to 2.3% by 2011, and to provide family planning to 24% of reproductive-age women whereby 1 million conceptions would be prevented. Indirect measures to curb fertility include raising literacy promoting the education of girls, improving the status and health conditions of women, and reducing maternal and child mortality. A media campaign has started to encourage a small family model. The low legal, social, educational, and employment status of women poses obstacles to this plan, however, the revision of laws that conflict with these goals has been urged. In other Islamic countries such as Turkey, Tunisia, Indonesia, Pakistan, and Bangladesh, female sterilization is legal. Abortion in Iran remains banned except for saving the life of the mother. PMID:12343087

  16. An investigation of a sterile access technique for the repair and adjustment of sterile spacecraft

    NASA Technical Reports Server (NTRS)

    Farmer, F. H.; Fuller, H. V.; Hueschen, R. M.

    1973-01-01

    A description is presented of a unique system for the sterilization and sterile repair of spacecraft and the results of a test program designed to assess the biological integrity and engineering reliability of the system. This trailer-mounted system, designated the model assembly sterilizer for testing (MAST), is capable of the dry-heat sterilization of spacecraft and/or components less than 2.3 meters in diameter at temperatures up to 433 K and the steam sterilization of components less than 0.724 meter in diameter. Sterile access to spacecraft is provided by two tunnel suits, called the bioisolator suit systems (BISS), which are contiguous with the walls of the sterilization chambers. The test program was designed primarily to verify the biological and engineering reliability of the MAST system by processing simulated space hardware. Each test cycle simulated the initial sterilization of a spacecraft, sterile repair of a failed component, removal of the spacecraft from the MAST for mating with the bus, and a sterile recycle repair.

  17. EPR STUDIES OF THERMALLY STERILIZED VASELINUM ALBUM.

    PubMed

    Ramos, Paweł; Pilawa, Barbara

    2015-01-01

    Electron paramagnetic resonance (EPR) spectroscopy was used for examination of free radicals in thermally treated vaselinum album (VA). Thermal treatment in hot air as sterilization process was tested. Conditions of thermal sterilization were chosen according to the pharmaceutical norms. Vaselinum album was heated at the following conditions (T--temperature, t--time): T = 160°C and t = 120 min, T = 170°C and t = 60 min and T = 180°C and t = 30 min. The aim of this work was to determine concentration and free radical properties of thermally sterilized VA. EPR analysis for VA was done 15 min after sterilization. EPR measurements were done at room temperature. EPR spectra were recorded in the range of microwave power of 2.2-70 mW. g-Factor, amplitudes (A) and line width (ΔBpp) of the spectra were determined. The shape of the EPR spectra was analyzed. Free radical concentration (N) in the heated samples was determined. EPR spectra were not obtained for the non heated VA. EPR spectra were detected for all thermally sterilized samples. The spectra revealed complex character, their asymmetry depends on microwave power. The lowest free radicals concentration was found for the VA sterilized at 180°C during 30 min. EPR spectroscopy is proposed as the method useful for optimization of sterilization process of drugs. PMID:26647625

  18. New sterilization technologies alternative to ethylene oxide

    NASA Astrophysics Data System (ADS)

    Tabrizian, Maryam; Lerouge, Sophie; Debrie, Anne; Yahia, L'Hocine

    1997-06-01

    Sterilization of biomedical devices may induce bulk and surface modification, responsible for the decrease or loss of their biofunctionality. Pure ethylene oxide (EO) at low temperature and new alternative techniques such as cold gas plasma sterilization have been developed for heat-sensitive polymers. There is a lack of the knowledge concerning their safety in terms of materials damage and consequences on the biofunctionality of sterilized devices. The objective of our work consists in studying bulk and surface changes in biomedical devices induced by these two sterilization techniques. Samples from PVC, Polyurethane, Polyacrylate and Polyethylene-based medical devices are subjected to 1, 5, and 10 sterilization cycles by Steri-Vac-3M (pure EO), Sterrad-100$TM, J&J (gas plasma + H2O2), and studied by X-rays photoelectron spectroscopy. Preliminary results show an increasing in Oxygen/Carbon ratio by a factor of 1.3 to 4.4 between the first and tenth cycle indicating the surface oxidation by gas plasma sterilization processes. Some changes in C-C chemical bounding are associated with EO sterilization.

  19. Characteristics of Surface Sterilization using ECR Plasma

    NASA Astrophysics Data System (ADS)

    Yonesu, Akira; Hara, Kazufumi; Nishikawa, Tatsuya; Hayashi, Nobuya

    2015-09-01

    Plasma sterilization techniques have superior characteristics such as a short treatment times, non-toxicity and low thermal damages on the sterilized materials. In plasma sterilization, microorganisms can be sterilized by active radicals, energetic charged particles, and vacuum UV radiation. The influence of each factor depends on the plasma operating parameters. Microwave discharges under the electron cyclotron resonance (ECR) condition produce higher electron temperature and density plasma as compared with other plasma generation techniques. In the present study, characteristics of surface sterilization using ECR plasma have been investigated.The experiment was performed in the vacuum chamber which contains a magnet holder. A pair of rectangular Sm-Co permanent magnets is aligned parallel to each other within the magnet holder. The region of the magnetic field for ECR exists near the magnet holder surface. When the microwave is introduced into the vacuum chamber, a ECR plasma is produced around surface of the magnet holder. High energy electrons and oxygen radicals were observed at ECR zone by electric probe method and optical spectroscopic method. Biological indicators (B.I.) having spore of 106 was sterilized in 2min for oxygen discharge. The temperature of the B.I. installation position was about 55°. The sterilization was achieved by the effect of oxygen radicals and high energy electrons.

  20. Prospects for vector control through sterilization procedures

    PubMed Central

    Smith, Carroll N.

    1963-01-01

    Interest in sterilization as a possible method for controlling insects of public health importance can be said to have arisen first in the mid-fifties, when the screw-worm fly was successfully eradicated from the island of Curaçao by the release over the entire island of large numbers of male flies sterilized by gamma-radiation. Since then, many studies on the sterilization of various insect vectors of disease have been carried out. This paper reviews these studies and discusses the present position regarding vector control by sterilization procedures, with special reference to the use of chemosterilants. These compounds have certain advantages over radiation since they can be used not only as a substitute for X-rays or gamma-rays in the sterilization of insects specially reared for release in large numbers, but also as a means of inducing sterility in natural populations of insects. The author emphasizes that chemosterilants cannot at present be recommended as a practical control or eradication procedure for any vector species of insect, but considers that this extension of the sterilization method holds great promise and merits intensive investigation. PMID:20604181

  1. Parameters governing steam sterilization of deadlegs.

    PubMed

    Young, J H; Ferko, B L; Gaber, R P

    1994-01-01

    Use of saturated steam for sterilization-in-place (SIP) is limited by factors effecting displacement of air from deadlegs. Effects of tube diameter, length, orientation and position within a deadleg were quantitatively studied by examining temperature profiles and rates of kill of Bacillus stearothermophilus spores. Tube diameter had the greatest effect on sterilization. For small diameter tubes, 0.4 cm inside diameter (ID), air displacement was minimal and due mainly to diffusion. 8.8 cm long tubes with 0.4 cm IDs could not be sterilized at 121 degrees C. As tube diameter was increased and buoyant driven convective flow became dominant over viscous forces, sterilization was achieved and tube orientation became critical. Sterilization time, as defined by a twelve log reduction in spore population, was 75 minutes in a 19.0 cm long vertical tube with 1.7 cm ID, whereas 167 minutes were required for an 8.8 cm long tube with 1.0 cm ID. For 8.8 cm long tubes, only the 1.7 cm ID tube could be sterilized when orientated 5 degrees above horizontal. Data show that length to diameter ratios, L/Ds, do not provide a general guideline which can be used to predict sterilization. In the absence of steam bleeders, equipment should be designed to assure strong buoyancy driven convective flow to assure adequate air removal. This requires elimination of small diameter deadlegs (0.4 cm ID and less) and vertical positioning of deadlegs. PMID:8069515

  2. Safety and efficacy of hysteroscopic sterilization compared with laparoscopic sterilization: an observational cohort study

    PubMed Central

    Mao, Jialin; Pfeifer, Samantha; Schlegel, Peter

    2015-01-01

    Objective To compare the safety and efficacy of hysteroscopic sterilization with the “Essure” device with laparoscopic sterilization in a large, all-inclusive, state cohort. Design Population based cohort study. Settings Outpatient interventional setting in New York State. Participants Women undergoing interval sterilization procedure, including hysteroscopic sterilization with Essure device and laparoscopic surgery, between 2005 and 2013. Main outcomes measures Safety events within 30 days of procedures; unintended pregnancies and reoperations within one year of procedures. Mixed model accounting for hospital clustering was used to compare 30 day and 1 year outcomes, adjusting for patient characteristics and other confounders. Time to reoperation was evaluated using frailty model for time to event analysis. Results We identified 8048 patients undergoing hysteroscopic sterilization and 44 278 undergoing laparoscopic sterilization between 2005 and 2013 in New York State. There was a significant increase in the use of hysteroscopic procedures during this period, while use of laparoscopic sterilization decreased. Patients undergoing hysteroscopic sterilization were older than those undergoing laparoscopic sterilization and were more likely to have a history of pelvic inflammatory disease (10.3% v 7.2%, P<0.01), major abdominal surgery (9.4% v 7.9%, P<0.01), and cesarean section (23.2% v 15.4%, P<0.01). At one year after surgery, hysteroscopic sterilization was not associated with a higher risk of unintended pregnancy (odds ratio 0.84 (95% CI 0.63 to 1.12)) but was associated with a substantially increased risk of reoperation (odds ratio 10.16 (7.47 to 13.81)) compared with laparoscopic sterilization. Conclusions Patients undergoing hysteroscopic sterilization have a similar risk of unintended pregnancy but a more than 10-fold higher risk of undergoing reoperation compared with patients undergoing laparoscopic sterilization. Benefits and risks of both procedures

  3. Laparoscopic sterilization in HIV-1-positive women.

    PubMed

    Intaraprasert, S; Taneepanichskul, S; Chaturachinda, K

    1996-11-01

    Laparoscopic sterilizations in HIV-1-positive women were performed. Patients, who were HIV-1-positive, underwent voluntary laparoscopic sterilization. The mean age of patients was 27.5 +/- 3.8 years. Most were of low socioeconomic status. The mean duration of the operation was 14.4 +/- 5.4 min. No accidental injury to the surgical team was recorded, and no complications occurred among the patients. It was concluded that laparoscopic sterilization in HIV-positive patients was safe with low risk of HIV transmission to the surgical team. PMID:8934065

  4. Spore-Forming Bacteria that Resist Sterilization

    NASA Technical Reports Server (NTRS)

    LaDuc, Myron; Venkateswaran, Kasthuri

    2003-01-01

    A report presents a phenotypic and genotypic characterization of a bacterial species that has been found to be of the genus Bacillus and has been tentatively named B. odysseensis because it was isolated from surfaces of the Mars Odyssey spacecraft as part of continuing research on techniques for sterilizing spacecraft to prevent contamination of remote planets by terrestrial species. B. odysseensis is a Gram-positive, facultatively anaerobic, rod-shaped bacterium that forms round spores. The exosporium has been conjectured to play a role in the elevated resistance to sterilization. Research on the exosporium is proposed as a path toward improved means of sterilization, medical treatment, and prevention of biofouling.

  5. Dynamic ultraviolet sterilization of different implant types.

    PubMed

    Delgado, A A; Schaaf, N G

    1990-01-01

    This paper investigates the use of the dynamic ultraviolet sterilization process with various dental implants, stainless steel orthopedic cortical bone screws, and polysulfone polymer healing caps. These biomaterials were inoculated with the spores of Bacillus subtilis and Bacillus stearothermophilus. They were then exposed to dynamic ultraviolet radiation in the chamber of a BUD Ultraviolet Device. Samples were incubated in trypticase soy broth at 37 degrees C and 56 degrees C, and they were subcultured onto an enriched agar medium. Results indicate that 16 seconds of dynamic ultraviolet radiation is effective in sterilizing these materials. This is significantly less time than other sterilization techniques presently used. PMID:2133336

  6. Gamma-ray irradiation, autoclave and ethylene oxide sterilization to thermosetting polyurethane: Sterilization to polyurethane

    NASA Astrophysics Data System (ADS)

    Hirata, Noriko; Matsumoto, Ken-Ichi; Inishita, Takashi; Takenaka, Yoshinori; Suma, Yasunori; Shintani, Hideharu

    1995-09-01

    Thermosetting polyurethane (PU) is widely used in a large variety of medical devices. 4,4'-methylenedianiline (MDA) was produced from PU by sterilization and it was studied for the relationship between urethane components or polymer characteristics and formation of MDA upon sterilization, using the commercially available dialyzers fabricated with different combination of isocyanate and polyol. We confirmed that the molecular-weight of polyol influenced the production of MDA upon sterilization.

  7. [Low-temperature sterilization for the surgical infection prophylaxis].

    PubMed

    Kornev, I I; Baranov, G A; Ul'ianov, V I

    2011-01-01

    The comparative characteristic of the accepted methods of low-temperature sterilization of medical equipment is given. Special attention is devoted to the surgical infection prophylaxis. The efficacy, expediency and safety of gas sterilization with ethilenoxide is proved. Plasmic methods of sterilization is recommended for use together with other methods of low-temperature sterilization. PMID:21716218

  8. 21 CFR 880.2800 - Sterilization process indicator.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Sterilization process indicator. 880.2800 Section... Monitoring Devices § 880.2800 Sterilization process indicator. (a) Biological sterilization process indicator—(1) Identification. A biological sterilization process indicator is a device intended for use by...

  9. Neutrino Oscillations with Three Active and Three Sterile Neutrinos

    NASA Astrophysics Data System (ADS)

    Kisslinger, Leonard S.

    2016-07-01

    This is an extension of estimates of the probability of μ to e neutrino oscillation with one sterile neutrino to three sterile neutrinos, using a 6x6 matrix. Since the mixing angle for only one sterile neutrino has been experimentally determined, we estimate the μ to e neutrino oscillation probability with different mixing angles for two of the sterile neutrinos.

  10. 21 CFR 880.6870 - Dry-heat sterilizer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Dry-heat sterilizer. 880.6870 Section 880.6870... Devices § 880.6870 Dry-heat sterilizer. (a) Identification. A dry-heat sterilizer is a device that is intended for use by a health care provider to sterilize medical products by means of dry heat....

  11. 21 CFR 880.6870 - Dry-heat sterilizer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Dry-heat sterilizer. 880.6870 Section 880.6870... Devices § 880.6870 Dry-heat sterilizer. (a) Identification. A dry-heat sterilizer is a device that is intended for use by a health care provider to sterilize medical products by means of dry heat....

  12. 21 CFR 880.6870 - Dry-heat sterilizer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Dry-heat sterilizer. 880.6870 Section 880.6870... Devices § 880.6870 Dry-heat sterilizer. (a) Identification. A dry-heat sterilizer is a device that is intended for use by a health care provider to sterilize medical products by means of dry heat....

  13. 21 CFR 880.6870 - Dry-heat sterilizer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Dry-heat sterilizer. 880.6870 Section 880.6870... Devices § 880.6870 Dry-heat sterilizer. (a) Identification. A dry-heat sterilizer is a device that is intended for use by a health care provider to sterilize medical products by means of dry heat....

  14. 21 CFR 880.6870 - Dry-heat sterilizer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dry-heat sterilizer. 880.6870 Section 880.6870... Devices § 880.6870 Dry-heat sterilizer. (a) Identification. A dry-heat sterilizer is a device that is intended for use by a health care provider to sterilize medical products by means of dry heat....

  15. ETHYLENE OXIDE CONTROL TECHNOLOGY DEVELOPMENT FOR HOSPITAL STERILIZERS

    EPA Science Inventory

    The report discusses the development of ethylene oxide (EO) control technology for hospital sterilizers. Hospitals sterilize heat-sensitive items in gas sterilizers that use a mixture of EO (12 wt %) and a chlorofluorocarbon (CFC) (88 wt %). The active sterilizing agent is EO. Th...

  16. 21 CFR 880.2800 - Sterilization process indicator.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Sterilization process indicator. 880.2800 Section... Monitoring Devices § 880.2800 Sterilization process indicator. (a) Biological sterilization process indicator—(1) Identification. A biological sterilization process indicator is a device intended for use by...

  17. 21 CFR 880.2800 - Sterilization process indicator.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Sterilization process indicator. 880.2800 Section... Monitoring Devices § 880.2800 Sterilization process indicator. (a) Biological sterilization process indicator—(1) Identification. A biological sterilization process indicator is a device intended for use by...

  18. 21 CFR 880.2800 - Sterilization process indicator.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Sterilization process indicator. 880.2800 Section... Monitoring Devices § 880.2800 Sterilization process indicator. (a) Biological sterilization process indicator—(1) Identification. A biological sterilization process indicator is a device intended for use by...

  19. 21 CFR 880.2800 - Sterilization process indicator.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Sterilization process indicator. 880.2800 Section... Monitoring Devices § 880.2800 Sterilization process indicator. (a) Biological sterilization process indicator—(1) Identification. A biological sterilization process indicator is a device intended for use by...

  20. Encapsulation process sterilizes and preserves surgical instruments

    NASA Technical Reports Server (NTRS)

    Montgomery, L. C.; Morelli, F. A.

    1964-01-01

    Ethylene oxide is blended with an organic polymer to form a sterile material for encapsulating surgical instruments. The material does not bond to metal and can be easily removed when the instruments are needed.

  1. The sterilization of gutta-percha points.

    PubMed

    Ehrmann, E H; Boquest, A; Faine, S

    1975-06-01

    The traditional methods employed for the sterilization of gutta-percha points are unsatisfactory. The use of propylene oxide for this purpose is described and experimental evidence is advanced to support this use. PMID:169776

  2. Sterile post-traumatic immunosuppression.

    PubMed

    Islam, Md Nahidul; Bradley, Benjamin A; Ceredig, Rhodri

    2016-04-01

    After major trauma, the human immune system initiates a series of inflammatory events at the injury site that is later followed by suppression of local inflammation favoring the repair and remodeling of the damaged tissues. This local immune response involves complex interactions between resident cells such as macrophages and dendritic cells, soluble mediators such as cytokines and chemokines, and recruited cells such as neutrophils, monocytes and mesenchymal stromal cells. If of sufficient magnitude, these initial immune responses nevertheless have systemic consequences resulting in a state called post-traumatic immunosuppression (PTI). However, controversy exists regarding the exact immunological changes occurring in systemic compartments triggered by these local immune responses. PTI is one of the leading causes of post-surgical mortality and makes patients vulnerable to hospital-acquired infections, multiple organ failure and many other complications. In addition, hemorrhage, blood transfusion, immunesenescence and immunosuppressant drugs aggravate PTI. PTI has been intensively studied, but published results are frequently cloudy. The purpose of this review is to focus on the contributions made by different responsive modalities to immunosuppression following sterile trauma and to try to integrate these into an overall scheme of PTI. PMID:27195120

  3. Sterile post-traumatic immunosuppression

    PubMed Central

    Islam, Md Nahidul; Bradley, Benjamin A; Ceredig, Rhodri

    2016-01-01

    After major trauma, the human immune system initiates a series of inflammatory events at the injury site that is later followed by suppression of local inflammation favoring the repair and remodeling of the damaged tissues. This local immune response involves complex interactions between resident cells such as macrophages and dendritic cells, soluble mediators such as cytokines and chemokines, and recruited cells such as neutrophils, monocytes and mesenchymal stromal cells. If of sufficient magnitude, these initial immune responses nevertheless have systemic consequences resulting in a state called post-traumatic immunosuppression (PTI). However, controversy exists regarding the exact immunological changes occurring in systemic compartments triggered by these local immune responses. PTI is one of the leading causes of post-surgical mortality and makes patients vulnerable to hospital-acquired infections, multiple organ failure and many other complications. In addition, hemorrhage, blood transfusion, immunesenescence and immunosuppressant drugs aggravate PTI. PTI has been intensively studied, but published results are frequently cloudy. The purpose of this review is to focus on the contributions made by different responsive modalities to immunosuppression following sterile trauma and to try to integrate these into an overall scheme of PTI. PMID:27195120

  4. Experimental Study of Sterilizing Molds by Ultrasound

    NASA Astrophysics Data System (ADS)

    Ren, Jin-lian; Niu, Yong

    1998-02-01

    An ultrasound method of sterilizing aspergillus flavus and fusarium is proposed and demonstrated. The dependence of sterilizing effect on ultrasonic intensity, frequency, and treatment time is experimentally investigated. The density of surviving spores decreases first with increasing ultrasonic frequency and then increases with the further increase of the frequency, that is to say, there exists the optimum frequency 26 kHz at which the killing rate is near 100%. The killing rate seems proportional to the intensity and the time.

  5. Production of a sterile species: Quantum kinetics

    SciTech Connect

    Ho, Chiu Man; Boyanovsky, D.; Ho, C.M.

    2007-04-23

    Production of a sterile species is studied within an effective model of active-sterile neutrino mixing in a medium in thermal equilibrium. The quantum kinetic equations for the distribution functions and coherences are obtained from two independent methods: the effective action and the quantum master equation. The decoherence time scale for active-sterile oscillations is tau(dec)=2/Gamma(aa), but the evolution of the distribution functions is determined by the two different time scales associated with the damping rates of the quasiparticle modes in the medium: Gamma(1)=Gamma(aa)cos^2theta(m); Gamma(2)=Gamma(aa)sin^2theta(m) where Gamma(aa) is the interaction rate of the active species in the absence of mixing and theta(m) the mixing angle in the medium. These two time scales are widely different away from Mikheyev-Smirnov-Wolfenstein resonances and preclude the kinetic description of active-sterile production in terms of a simple rate equation. We give the complete set of quantum kinetic equations for the active and sterile populations and coherences and discuss in detail the various approximations. A generalization of the active-sterile transition probability in a medium is provided via the quantum master equation. We derive explicitly the usual quantum kinetic equations in terms of the"polarization vector" and show their equivalence to those obtained from the quantum master equation and effective action.

  6. Health technology assessment: Off-site sterilization

    PubMed Central

    Dehnavieh, Reza; Mirshekari, Nadia; Ghasemi, Sara; Goudarzi, Reza; Haghdoost, AliAkbar; Mehrolhassani, Mohammad Hossain; Moshkani, Zahra; Noori Hekmat, Somayeh

    2016-01-01

    Background: Every year millions of dollars are expended to equip and maintain the hospital sterilization centers, and our country is not an exception of this matter. According to this, it is important to use more effective technologies and methods in health system in order to reach more effectiveness and saving in costs. This study was conducted with the aim of evaluating the technology of regional sterilization centers. Methods: This study was done in four steps. At the first step, safety and effectiveness of technology was studied via systematic study of evidence. The next step was done to evaluate the economical aspect of off-site sterilization technology using gathered data from systematic review of the texts which were related to the technology and costs of off-site and in-site hospital sterilization. Third step was conducted to collect experiences of using technology in some selected hospitals around the world. And in the last step different aspects of acceptance and use of this technology in Iran were evaluated. Results: Review of the selected articles indicated that efficacy and effectiveness of this technology is Confirmed. The results also showed that using this method is not economical in Iran. Conclusion: According to the revealed evidences and also cost analysis, due to shortage of necessary substructures and economical aspect, installing the off-site sterilization health technology in hospitals is not possible currently. But this method can be used to provide sterilization services for clinics and outpatients centers. PMID:27390714

  7. Is cosmology compatible with sterile neutrinos?

    SciTech Connect

    Dodelson, Scott; Melchiorri, Alessandro; Slosar, Anze; /Ljubljana U.

    2005-11-01

    By combining data from cosmic microwave background (CMB) experiments (including the recent BOOMERANG-2K2 results), large scale structure (LSS) and Lyman-{alpha} forest observations, we constrain the hypothesis of a fourth, sterile, massive neutrino. For the 3 massless + 1 massive neutrino case we bound the mass of the sterile neutrino to m{sub s} < 0.55eV at 95% c.l.. These results exclude at high significance the sterile neutrino hypothesis as an explanation of the LSND anomaly. We then generalize the analysis to account for active neutrino masses (which tightens the limit to m{sub s} < 0.51eV) and the possibility that the sterile abundance is not thermal. In the latter case, the constraints in the (mass, density) plane are non-trivial. For a mass of > 1eV or < 0.05eV the cosmological energy density in sterile neutrinos is always constrained to be {omega}{sub {nu}} < 0.005 at 95% c.l.. However, for a sterile neutrino mass of {approx} 0.25 eV, {omega}{sub {nu}} can be as large as 0.015.

  8. Sterilization techniques for biodegradable scaffolds in tissue engineering applications

    PubMed Central

    Dai, Zheng; Ronholm, Jennifer; Tian, Yiping; Sethi, Benu; Cao, Xudong

    2016-01-01

    Biodegradable scaffolds have been extensively studied due to their wide applications in biomaterials and tissue engineering. However, infections associated with in vivo use of these scaffolds by different microbiological contaminants remain to be a significant challenge. This review focuses on different sterilization techniques including heat, chemical, irradiation, and other novel sterilization techniques for various biodegradable scaffolds. Comparisons of these techniques, including their sterilization mechanisms, post-sterilization effects, and sterilization efficiencies, are discussed. PMID:27247758

  9. Using high-temperature formaldehyde sterilization as a model for studying gaseous sterilization.

    PubMed

    Mosley, Gregg A

    2008-01-01

    This study uses the high-temperature formaldehyde sterilization system provided by the Harvey Chemiclave, manufactured by Barnstead Thermolyne Corporation (Dubuque, IA), as a model to investigate certain phenomena associated with gaseous chemical sterilization systems. Although formaldehyde sterilization presents some unique and complex system attributes, the current studies provide helpful insights into general sterilization methods by chemicals in the gaseous state. Both population recovery and fraction negative (FN) techniques were used to assay surviving populations from biological indicators of the organism Geobacillus stearothermophilus following exposure to incremental Chemiclave cycles. Models 5500 and 6000 of the Barnstead/Thermolyne Chemiclave were used in the study. Reusable instruments such as scalers, explorers, and various hinged pieces were tested in minimum versus maximum load studies. Population recovery study results demonstrated that lethality rates increase with time throughout the Chemiclave sterilization process and that there are significant variations in lethality according to load location. The population recovery data in conjunction with the FN studies and temperature data confirm that one-half the full-cycle time is not a good estimator of one-half the full-cycle lethality because lethality curves are concave downward and lethality varies by load location. This conclusion can also be applied to other types of gaseous, chemical sterilization such as ethylene oxide. The work outlined in this study was a result of investigations into the parameters affecting formaldehyde chemical vapor sterilization with the Harvey Chemiclave sterilizer. During these studies, it became apparent that results clearly depicted the effects of continued acceleration of the rate of microbial lethality, as well as variations in delivered lethality as a function of position in the sterilizer load. This publication focuses on these observations because they are

  10. Electroporation System for Sterilizing Water

    NASA Technical Reports Server (NTRS)

    Schlager, Kenneth J.

    2005-01-01

    A prototype of an electroporation system for sterilizing wastewater or drinking water has been developed. In electroporation, applied electric fields cause transient and/or permanent changes in the porosities of living cells. Electroporation at lower field strengths can be exploited to increase the efficiency of chemical disinfection (as in chlorination). Electroporation at higher field strengths is capable of inactivating and even killing bacteria and other pathogens, without use of chemicals. Hence, electroporation is at least a partial alternative to chlorination. The transient changes that occur in micro-organisms at lower electric-field strengths include significantly increased uptake of ions and molecules. Such increased uptake makes it possible to achieve disinfection at lower doses of chemicals (e.g., chlorine or ozone) than would otherwise be needed. Lower doses translate to lower costs and reduced concentrations of such carcinogenic chemical byproducts as trichloromethane. Higher electric fields cause cell membranes to lose semipermeability and thereby become unable to function as selective osmotic barriers between the cells and the environment. This loss of function is the cause of the cell death at higher electric-field intensities. Experimental evidence does not indicate cell lysis but, rather, combined leaking of cell proteins out of the cells as well as invasion of foreign chemical compounds into the cells. The concept of electroporation is not new: it has been applied in molecular biology and genetic engineering for decades. However, the laboratory-scale electroporators used heretofore have been built around small (400-microliter) cuvettes, partly because the smallness facilitates the generation of electric fields of sufficient magnitude to cause electroporation. Moreover, most laboratory- scale electroporators have been designed for testing static water. In contrast, the treatment cell in the present system is much larger and features a flow

  11. Improving sterile male performance in support of programmes integrating the sterile insect technique against fruit flies

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The Sterile Insect Technique (SIT) is being applied against fruit fly pests in many areas of the world. Currently, factories have the capacity to produce several billion sterile male insects per week and to make them available for, irradiatiation and shipment to their destinations, where the emergin...

  12. Effect of sterilization on contaminated sponges.

    PubMed

    Kuritani, R H; McDonald, N J; Sydiskis, R J

    1993-02-01

    Sponges are routinely used as a storage medium for endodontic files during clinical practice; however, very little research has been done to determine the effectiveness of sterilization procedures for these contaminated sponges. The purpose of this in vitro study was to determine the efficacy of chemical vapor sterilizers (chemiclaves), steam pressure sterilizers (autoclaves), and dry heat sterilizers on laboratory contaminated sponges. Four different types of sponges were used in this study: a black, relatively nonporous sponge; a red, semiporous stationary sponge; a blue, endodontic sponge, and a yellow, common household sponge. Natural sponges were eliminated from the study, because their large pore size made them unsuitable as a storage medium for endodontic instruments. The sponges were divided into three groups: chemiclave, autoclave, and dry heat. Five samples of each sponge type were impregnated with biological indicating strips containing spores of Bacillus stearothermophilus. Each sponge was subjected to 25 cycles of sterilization. The spore strip indicator was inserted into the sponges at 1, 5, 10, 15, 20, and 25 cycles. The spore strip was cultivated in trypticase soy broth medium solution at 55 +/- 1 degree C for 7 days. At 7 days the culture vials were read for turbidity; its presence indicating a positive culture. The samples that were subjected to chemiclaving demonstrated positive cultures of 0.00%, 0.00%, and 30.00% and those to autoclaving 3.33%, 0.00%, and 0.00% positive cultures for the black, red, and blue sponge types, respectively. None of the sponges survived dry heat sterilization. The O-Cell-O sponges become unusable when subjected to all of the sterilization methods used in this study. PMID:8509738

  13. Experiences of coercion to sterilize and forced sterilization among women living with HIV in Latin America

    PubMed Central

    Kendall, Tamil; Albert, Claire

    2015-01-01

    Introduction Forced and coerced sterilization is an internationally recognized human rights violation reported by women living with HIV (WLHIV) around the globe. Forced sterilization occurs when a person is sterilized without her knowledge or informed consent. Coerced sterilization occurs when misinformation, intimidation tactics, financial incentives or access to health services or employment are used to compel individuals to accept the procedure. Methods Drawing on community-based research with 285 WLHIV from four Latin American countries (El Salvador, Honduras, Mexico and Nicaragua), we conduct thematic qualitative analysis of reports of how and when healthcare providers pressured women to sterilize and multivariate logistic regression to assess whether social and economic characteristics and fertility history were associated with pressure to sterilize. Results A quarter (23%) of the participant WLHIV experienced pressure to sterilize post-diagnosis. WLHIV who had a pregnancy during which they (and their healthcare providers) knew their HIV diagnosis were almost six times more likely to experience coercive or forced sterilization than WLHIV who did not have a pregnancy with a known diagnosis (OR 5.66 CI 95% 2.35–13.58 p≤0.001). WLHIV reported that healthcare providers told them that living with HIV annulled their right to choose the number and spacing of their children and their contraceptive method, employed misinformation about the consequences of a subsequent pregnancy for women's and children's health, and denied medical services needed to prevent vertical (mother-to-child) HIV transmission to coerce women into accepting sterilization. Forced sterilization was practiced during caesarean delivery. Conclusions The experiences of WLHIV indicate that HIV-related stigma and discrimination by healthcare providers is a primary driver of coercive and forced sterilization. WLHIV are particularly vulnerable when seeking maternal health services. Health worker

  14. Sterilization of Fuji pressure-sensitive film.

    PubMed

    Liggins, A B; Hardie, W R; Finlay, J B

    1994-11-01

    Fuji Prescale film is a pressure-sensitive medium which produces a characteristic pink stain on the application of pressure. Up to a saturation level, increases in pressure will produce a denser stain, thereby providing a method of determining pressures within the interface between two articulating surfaces. The relationship between the magnitude of applied pressure and the optical density of the resulting stain is non-linear; this relationship also varies with ambient temperature and humidity, in addition to load rate, and therefore requires a calibration procedure prior to use. The use of Fuji prescale film for recording interface pressures within the joint space in vivo has been widely reported; however, the object of this study was to assess the effects of sterilizing this medium, with a view to future in vivo applications. Samples of Fuji film were sterilized using a standard ethylene oxide (ETO) gas process and their subsequent pressure-recording properties were compared to a control group of samples. The 'optical-density vs pressure' relationship for the sterilized group was significantly different from that of the control group (paired Student's t-test, P < = 0.001); however, both groups provided reliable data across the same pressure-range and both exhibited an excellent degree of repeatability (coefficient of variation < 2.5%). It was concluded that Fuji film will continue to produce pressure-stains following ETO sterilization; however, the calibration of this film will only be valid if it is conducted using film from the sterilized group. PMID:7858782

  15. Vaporized hydrogen peroxide sterilization of freeze dryers.

    PubMed

    Johnson, J W; Arnold, J F; Nail, S L; Renzi, E

    1992-01-01

    The feasibility of using vapor hydrogen peroxide (VHP) as an alternative to steam sterilization has been examined using a pilot plant freeze dryer equipped with a prototype vapor generator. Specific objectives of the study discussed in this presentation were to: 1. Identify critical process variables affecting the lethality of VHP to Bacillus stearothermophilus spores, particularly within dead legs in the system. 2. Measure the efficacy of system degassing after sterilization. 3. Determine the effect of repeated sterilization cycles on the integrity of elastomeric components of the freeze dryer. Penetration of adequate concentrations of hydrogen peroxide vapor into small diameter piping, such as tubing connected to pressure gauges, is the most challenging aspect of VHP sterilization of freeze dryers. Prior to equipment modifications, spore strips placed within such dead legs remained positive irrespective of the number of gas/degas pulses and system pressure. Equipment modifications necessary to effect complete kill of biological indicators placed in system dead legs is discussed. Results of this study support the conclusion that vaporized hydrogen peroxide shows promise as an alternative sterilization method for freeze dryers. PMID:1474433

  16. Dynamic sterilization of titanium implants with ultraviolet light.

    PubMed

    Singh, S; Schaaf, N G

    1989-01-01

    All implantable devices must be sterile. However, autoclaves produce poor surface properties that jeopardize the integration process. The application of a modified ultraviolet light source has proven to enhance bioreactivity by controlling surface properties, but it lacks validation of its sterilization capabilities. Forty-eight titanium implants were contaminated with spores of the biological indicator Bacillus stearothermophilus and subjected to "dynamic sterilization" by ultraviolet light. Forty-seven of the implants were successfully sterilized, as indicated by not producing turbidity in a suitable growth medium. This sterilization technique only requires a 20-second exposure to achieve sterility. PMID:2599585

  17. Radiation sterilization of tissue allografts: A review

    PubMed Central

    Singh, Rita; Singh, Durgeshwer; Singh, Antaryami

    2016-01-01

    Tissue substitutes are required in a number of clinical conditions for treatment of injured and diseased tissues. Tissues like bone, skin, amniotic membrane and soft tissues obtained from human donor can be used for repair or reconstruction of the injured part of the body. Allograft tissues from human donor provide an excellent alternative to autografts. However, major concern with the use of allografts is the risk of infectious disease transmission. Therefore, tissue allografts should be sterilized to make them safe for clinical use. Gamma radiation has several advantages and is the most suitable method for sterilization of biological tissues. This review summarizes the use of gamma irradiation technology as an effective method for sterilization of biological tissues and ensuring safety of tissue allografts. PMID:27158422

  18. Light sterile neutrinos in the early universe

    SciTech Connect

    Lunardini, Cecilia

    2014-06-24

    Cosmological and terrestrial data suggests the number of light neutrinos may be greater than 3, motivating a careful reexamination of cosmological bounds on extra light species. Big bang nucleosynthesis constrains the number of relativistic neutrino species present during nucleosynthesis, N{sub eff}{sup BBN}, while measurements of the cosmic microwave background (CMB) angular power spectrum constrain the effective energy density in relativistic neutrinos at the time of matter-radiation equality, N{sub eff}{sup CMB}. We review a scenario with two sterile neutrinos and explore whether partial thermalization of the sterile states can ease the tension between cosmological constraints on N{sub eff}{sup BBN} and terrestrial data. We conclude that, still, two additional light sterile neutrinos species cannot fit all the data at the 95% confidence level.

  19. Radiation sterilization of tissue allografts: A review.

    PubMed

    Singh, Rita; Singh, Durgeshwer; Singh, Antaryami

    2016-04-28

    Tissue substitutes are required in a number of clinical conditions for treatment of injured and diseased tissues. Tissues like bone, skin, amniotic membrane and soft tissues obtained from human donor can be used for repair or reconstruction of the injured part of the body. Allograft tissues from human donor provide an excellent alternative to autografts. However, major concern with the use of allografts is the risk of infectious disease transmission. Therefore, tissue allografts should be sterilized to make them safe for clinical use. Gamma radiation has several advantages and is the most suitable method for sterilization of biological tissues. This review summarizes the use of gamma irradiation technology as an effective method for sterilization of biological tissues and ensuring safety of tissue allografts. PMID:27158422

  20. Sterilization and disinfection in the physician's office.

    PubMed Central

    Drummond, D C; Skidmore, A G

    1991-01-01

    OBJECTIVE: To review the principles and practice of sterilization and disinfection of medical instruments in the office setting. DATA SOURCES: Searches of MEDLINE for articles published from 1980 to 1990 on disinfection, sterilization, cross infection, surgical instruments and iatrogenic disease, bibliographies, standard texts and reference material located in a central processing department. STUDY SELECTION: We reviewed surveys of decontamination practices in physicians' offices, reviews of current recommendations for office decontamination procedures, case reports of cross infection in offices and much of the standard reference material on decontamination theory and practice. DATA SYNTHESIS: There have been few surveys of physicians' decontamination practices and few case reports of cross infection. Office practitioners have little access to practical information on sterilization and disinfection. CONCLUSION: The increasing threat of cross infection from medical instruments calls for greater knowledge about decontamination. We have adapted material from various sources and offer a primer on the subject. PMID:1913427

  1. Biological Sterilization of Returned Mars Samples

    NASA Technical Reports Server (NTRS)

    Allen, C. C.; Albert, F. G.; Combie, J.; Bodnar, R. J.; Hamilton, V. E.; Jolliff, B. L.; Kuebler, K.; Wang, A.; Lindstrom, D. J.; Morris, P. A.

    1999-01-01

    Martian rock and soil, collected by robotic spacecraft, will be returned to terrestrial laboratories early in the next century. Current plans call for the samples to be immediately placed into biological containment and tested for signs of present or past life and biological hazards. It is recommended that "Controlled distribution of unsterilized materials from Mars should occur only if rigorous analyses determine that the materials do not constitute a biological hazard. If any portion of the sample is removed from containment prior to completion of these analyses it should first be sterilized." While sterilization of Mars samples may not be required, an acceptable method must be available before the samples are returned to Earth. The sterilization method should be capable of destroying a wide range of organisms with minimal effects on the geologic samples. A variety of biological sterilization techniques and materials are currently in use, including dry heat, high pressure steam, gases, plasmas and ionizing radiation. Gamma radiation is routinely used to inactivate viruses and destroy bacteria in medical research. Many commercial sterilizers use Co-60 , which emits gamma photons of 1.17 and 1.33 MeV. Absorbed doses of approximately 1 Mrad (10(exp 8) ergs/g) destroy most bacteria. This study investigates the effects of lethal doses of Co-60 gamma radiation on materials similar to those anticipated to be returned from Mars. The goals are to determine the gamma dose required to kill microorganisms in rock and soil samples and to determine the effects of gamma sterilization on the samples' isotopic, chemical and physical properties. Additional information is contained in the original extended abstract.

  2. STERILIZED in the Name of Public Health

    PubMed Central

    Stern, Alexandra Minna

    2005-01-01

    In exploring the history of involuntary sterilization in California, I connect the approximately 20 000 operations performed on patients in state institutions between 1909 and 1979 to the federally funded procedures carried out at a Los Angeles County hospital in the early 1970s. Highlighting the confluence of factors that facilitated widespread sterilization abuse in the early 1970s, I trace prosterilization arguments predicated on the protection of public health. This historical overview raises important questions about the legacy of eugenics in contemporary California and relates the past to recent developments in health care delivery and genetic screening. PMID:15983269

  3. Decontamination formulations for disinfection and sterilization

    DOEpatents

    Tucker, Mark D.; Engler, Daniel E.

    2007-09-18

    Aqueous decontamination formulations that neutralize biological pathogens for disinfection and sterilization applications. Examples of suitable applications include disinfection of food processing equipment, disinfection of areas containing livestock, mold remediation, sterilization of medical instruments and direct disinfection of food surfaces, such as beef carcasses. The formulations include at least one reactive compound, bleaching activator, inorganic base, and water. The formulations can be packaged as a two-part kit system, and can have a pH value in the range of 7-8.

  4. Calculating Neutrino Oscillations with Sterile Neutrinos

    NASA Astrophysics Data System (ADS)

    Linehan, Bryan

    2014-09-01

    In particle physics, it is currently known that three types of neutrinos exist that interact via the weak force. Referred to as ``flavors,'' they are distinguishable and named for the lepton they produce through charged current interactions: electron, muon, and tau. In a process called neutrino oscillation, one flavor of neutrino can change into another flavor as it propagates through space. At the moment, mild discrepancies between expected and measured neutrino oscillations suggest that more types of neutrinos that do not interact via the weak force exist: sterile neutrinos. The goal of this project was to calculate non-sterile flavor oscillation probabilities when 1, 2 or 3 sterile neutrinos were assumed to exist. An application has been written in Mathematica that calculates these probabilities with the neutrino masses, linear relationships between mass and flavor states, values of CP symmetry violating constants, and constant densities of media in which the neutrinos propagate set as parameters. The application was published online for researchers to use as a tool when considering the existence of sterile neutrinos. In the immediate future, the insights this application gives into neutrino oscillations will be studied and reported. In particle physics, it is currently known that three types of neutrinos exist that interact via the weak force. Referred to as ``flavors,'' they are distinguishable and named for the lepton they produce through charged current interactions: electron, muon, and tau. In a process called neutrino oscillation, one flavor of neutrino can change into another flavor as it propagates through space. At the moment, mild discrepancies between expected and measured neutrino oscillations suggest that more types of neutrinos that do not interact via the weak force exist: sterile neutrinos. The goal of this project was to calculate non-sterile flavor oscillation probabilities when 1, 2 or 3 sterile neutrinos were assumed to exist. An application

  5. Sterilization of Cotton Fabrics Using Plasma Treatment

    NASA Astrophysics Data System (ADS)

    Shahidi, S.; Ghoranneviss, M.

    2013-10-01

    Microbial contamination induces surface deformations and strength degradation of cotton fabrics by invading deeply into the fibers. In this study, the sterilization effects of low pressure plasmas on bacteria-inoculated cotton fabrics were investigated. Oxygen plasma treatment completely sterilized the cotton fabrics inoculated with various concentrations of staphylococcus aureus. Also, the influence of plasma treatment on physical properties of fabrics was examined. It was found that the plasma treatment did not affect ultimate tensile strength and surface morphology of the fabrics because it took advantage of relatively low plasma temperature.

  6. Low temperature steam and formaldehyde sterilization.

    PubMed

    Robertshaw, R G

    1983-09-01

    A standard low temperature steam/formaldehyde autoclave was tested according to the manufacturer's instructions, using a range of test pieces containing Bacillus stearothermophilus spores as the challenge organism. There were failures in killing the challenge organism and the reasons for these are discussed. A description of modifications made to the autoclave is given together with details of an improved operating cycle. The performance of the modified autoclave was greatly improved and conditions were established for reliable and consistent sterilization of all the test pieces. A commercially produced prototype autoclave similarly modified also showed effective sterilization. PMID:6195245

  7. Effects of sterilization on wear in total knee arthroplasty.

    PubMed

    White, S E; Paxson, R D; Tanner, M G; Whiteside, L A

    1996-10-01

    Twenty-nine Ortholoc II ultrahigh molecular weight polyethylene tibial components were retrieved from 27 patients at revision surgery from the same hospital. The polyethylene material grade, method of sterilization, and sterilization dosage for 26 of the tibial components were determined by tracing the material lot number for each component. Each tibial surface was scored for wear using a qualitative scoring system that evaluated delamination, pitting, scratching, cold flow, abrasion, and burnishing. After the wear score analysis, 14 of the 26 components were analyzed to determine the physical and mechanical properties of the polyethylene including toughness and elongation. Seven of these 14 components were sterilized using ethylene oxide and 7 were sterilized using gamma radiation. Tibial components sterilized with gamma radiation had significantly higher wear rates than those sterilized with ethylene oxide. Thirteen of the 18 components sterilized with gamma radiation had delamination of the articular surface compared with 2 of 8 components sterilized with ethylene oxide. Mechanical properties were significantly affected by the sterilization method. Components sterilized with ethylene oxide had significantly higher toughness and percent elongation than those sterilized with gamma radiation. These findings suggest that ethylene oxide sterilization caused less microstructural damage to the polyethylene and resulted in significantly less wear than was found in those components sterilized with gamma radiation. PMID:8895634

  8. Biological monitoring of sterilizers and sterilization failures in Norwegian dental offices in 1985 and 1996.

    PubMed

    Skaug, N; Lingaas, E; Nielsen, O; Palenik, C J

    1999-08-01

    It is essential that dental office sterilizers be regularly challenged with biological indicators (BIs) in order to prove that the test spores are being killed during sterilization. The aims of the study were to biologically monitor Norwegian dental office sterilizers and to identify factors contributing to sterilization failure. In 1985, participants received a packet containing: (i) 4 BI units; (ii) a set of instructions; (iii) a questionnaire concerning operation (including biological monitoring) of the office sterilizer(s), and (iv) a return-address envelope. In 1996, offices were sent (i) a survey which included demographic questions and inquiries concerning instrument sterilization processes; (ii) 2 sets of 3 BI units with instructions for their use on 2 different days; (iii) 1 control BI unit that was not to be processed, and (iv) a return-address envelope. Both private and public offices participated. Response rate to the 1996 study was 60%, which was 9.1% of all dental offices in Norway. Testing results indicated a 6.3% overall sterilization failure rate. Three out of 163 steam autoclaves (SAs) (1.8% of total) and 14 out of 109 dry heat (DH) ovens (12.8% of total) failed. DH ovens were over 7 times more likely to fail BI testing than were SAs (chi2, P < 0.01). Demographic or hygiene procedural factors could not be correlated to sterilization performance (chi2, P > 0.05). The failure rate for SAs (n = 216) in 1985 was almost 5 times greater than in 1996 (8.8% vs 1.8%). Improvement in sterilizer performance during the decade may be related to issuance in 1986 of Norway's 1st infection control guidelines for dentistry and greater awareness of infection control practices and/or to increases over the previous 10 years in the number of postgraduate courses offered in infection control. The current Norwegian guidelines on infection control practices in public health services, including dentistry, recommend regular biological monitoring of sterilizers without

  9. System for sterilizing objects. [cleaning space vehicle systems

    NASA Technical Reports Server (NTRS)

    Bryan, C. J.; Wright, E. E., Jr.; Moyers, C. V. (Inventor)

    1981-01-01

    A system for producing a stream of humidified sterilizing gas for sterilizing objects such as the water systems of space vehicles and the like includes a source of sterilant gas which is fed to a mixing chamber which has inlet and outlet ports. The level of the water only partially fills the mixing chamber so as to provide an empty space adjacent the top of the chamber. A heater is provided for heating the water in the chamber so as to produce a humidified atmosphere. The sterilant gas is fed through an arcuate shaped tubular member connected to the inlet port of the mixing chamber for producing a vortex type of flow of sterilant gas into the chamber for humidification. A tubular member extends from the mixing chamber for supplying the humidified sterilant gas to the object for being sterilized. Scrubbers are provided for removing the sterilant gas after use.

  10. Proper monitoring of sterilization procedures used in oral surgery.

    PubMed

    Skaug, N

    1983-06-01

    The sterilization procedures used by oral surgeons in Norway have been surveyed. In 22 of the 25 oral surgical clinics controlled, instruments were sterilized by saturated steam at 121 degrees C or 134 degrees C; 3 used a dry heat oven sterilizer; dry heat and/or gas sterilization procedures supplemented steam sterilization in 17 clinics. When these sterilization procedures were monitored with biological indicators, 5 autoclaves (challenged with B. stearothermophilus spores), 2 dry heat sterilizers (B. subtilis spores), and all the Harvey Chemiclaves tested (B. subtilis spores) did not inactivate the bacterial spores. A biological monitoring system that fulfills the valid requirements for sterilization procedures given by the national health authorities and that is reliable, convenient, economical and self-contained should be used routinely in oral surgery clinics. PMID:6411637

  11. Selection of biological indicator for validating microwave heating sterilization.

    PubMed

    Sasaki, K; Mori, Y; Honda, W; Miyake, Y

    1998-01-01

    For the purpose of selecting an appropriate biological indicator for evaluation of the effects of microwave heating sterilization, we examined aerobic bacterial spores to determine whether microwaves have non-thermal sterilization effects. After microwave irradiation on dry bacterial spores (three species), none of the bacterial spores were killed. The survival rate of the spores after microwave irradiation of spore suspensions (twelve species) was compared with that after heating by a conventional method. The order of heat resistance in the bacterial species was similar between the two heating methods. Bacillus stearothermophilus spores were the most heat-resistant. These results suggest that microwaves have no non-thermal sterilization effects on bacterial spores, the specific resistant spores to microwave heating, and microwave heating sterilization can be evaluated in the same way as for conventional heating sterilization. As a biological indicator for evaluation of overkill sterilization, B. stearothermophilus spores may be appropriate for microwave heating sterilization as well as steam sterilization. PMID:9610169

  12. A general review of chemical sterilization in space research.

    PubMed

    Opfell, J B

    1964-01-01

    The unsolved problems in the biology and the chemistry of chemical sterilization are legion. This discussion of them emphasizes some interesting areas for useful research. Studies in molecular biology and cancer chemotherapy have produced information which has important implications in chemical sterilization, particularly with the alkylating and the oxidizing agents. Many of these problems must be solved soon if chemical sterilization is to play the role it should in space research by providing means for effectively controlling the rate and extent of mingling of the forms of terrestrial life with those of extraterrestrial life. In space research in the United States, recent work on chemical sterilization has laid heavy emphasis on the identification and exploration of principles of engineering sciences which control sterilization effectiveness. These principles are reviewed and their significance in chemical sterilization is discussed in terms of the engineering factors involved. Among these factors are: consequence of sterilant polymerization or reaction with the object to be sterilized; criteria for chemical sterilization process effectiveness; depletion of the concentration of the sterilant by evaporation or chemical reaction, including polymerization; obstacles to the diffusion or convection of the sterilizing chemical to the immediate vicinity of the microorganisms to be destroyed; protection of the microorganisms from direct contact with the sterilant; phase behavior of the sterilant in the environment of the sterilization process; presence of water or water vapor; the nature, sources and numbers of microorganisms which survive standard chemical sterilization processes; and the length of exposure required to sterilize at each temperature. The significance of chemical sterilization to space science has been well reviewed at the previous COSPAR symposia. Because several thorough reviews of the empirical knowledge concerning the effects of chemical agents on

  13. Gas plasma sterilization--application of space-age technology.

    PubMed

    Crow, S; Smith, J H

    1995-08-01

    Gas plasma sterilization is new to the healthcare field. The first such sterilizer has been manufactured by Advanced Sterilization Products (J&J, Irvine, CA). The system uses hydrogen peroxide as the substrate gas and radio frequency emissions to generate plasma. This system is a low-temperature, quick-acting process with no toxic residues. It appears that this sterilizer system holds promise in the healthcare field and could help to reduce the use of ethylene oxide. PMID:7594394

  14. Status of radiation sterilization of healthcare products in China

    NASA Astrophysics Data System (ADS)

    Zhu, Nankang; Wang, Chunlei; Teng, Weifang

    2004-09-01

    This paper describes the status of 60Co radiation facilities both in service and under construction in China and examines the future market for radiation sterilization of healthcare products. Policies for developing the industry of radiation sterilization are also put forward; these include implementation of appropriate quality systems, scale-up and merging of existing radiation facilities, development of electron beam radiation for sterilization purposes and increasing awareness of the technology of radiation sterilization.

  15. The sterility of hospital-prepared Soffban bandages.

    PubMed

    Wood, E V; Fenwick, H; Manning, M P; Mobbs, P

    2005-11-01

    An evaluation of the sterility of hospital-prepared Soffban bandages was undertaken. Discs of Bacillus stearothermophilus were inserted into the bandage rolls, prior to sterilization in "porous load" autoclaves. The discs were subsequently removed and placed in culture media, with growth of the organism indicating failure of sterilization. It was demonstrated that Soffban could not be sterilized reliably using standard hospital autoclave techniques. PMID:16019112

  16. Sterilization of Microorganisms by Ozone and Ultrasound

    NASA Astrophysics Data System (ADS)

    Krasnyj, V. V.; Klosovskij, A. V.; Panasko, T. A.; Shvets, O. M.; Semenova, O. T.; Taran, V. S.; Tereshin, V. I.

    2008-03-01

    The results of recent experimental methods of sterilization of microorganisms with the use of ozone and ultrasound are presented. The main aim was to optimize the process of sterilization in water solution taking into account the ozone concentration, the power of ultrasonic emitter and the temperature of water. In the present work, the ultrasonic cavitation with simultaneous ozone generation has been used. The high ozone concentration in water solution was achieved by two-barrier glow discharge generated at atmospheric pressure and a cooling thermo-electric module. Such a sterilizer consists of ozone generator in a shape of flat electrodes covered with dielectric material and a high-voltage pulsed power supply of 250 W. The sterilization camera was equipped with ultrasonic source operated at 100 W. The experiments on the inactivation of bacteria of the Bacillus Cereus type were carried out in the distilled water saturated by ozone. The ozone concentration in the aqueous solution was 10 mg/1, whereas the ozone concentration at the output of ozone generator was 30 mg/1. The complete inactivation of spores took 15 min. Selection of the temperature of water, the ozone concentrations and ultrasonic power allowed to determine the time necessary for destroying the row of microorganisms.

  17. Male sterility and hybrid seed production

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Sexual reproduction in angiosperms is a complex process that includes a portion of the vegetative generation and all of the sexual generation. Coordination of both female and male reproduction ontogenies must occur. An abnormality anywhere in this process may lead to sterility. Genetic (nuclear) and...

  18. The Decision for Male versus Female Sterilization.

    ERIC Educational Resources Information Center

    Clark, Margaret Pruitt; And Others

    1979-01-01

    The increasing popularity of sterilization underscores the need for knowledge about couples choosing male and female procedures. This research delineates four sets of variables that may be important for the decision and examines their relationship with the choice of male or female procedure among a sample of married couples. (Author)

  19. Sterilization: A Conference and a Report.

    ERIC Educational Resources Information Center

    Dillingham, Brint

    1978-01-01

    This article continues a series on Native American sterilization, based on a conference of the National Council of Churches' Interreligious Foundation for Community Organization (IFCO). Also included are an article and a report by the American Civil Liberties Union. (Author/RTS)

  20. Perspectives: Eugenics and Sterilization in the Heartland.

    ERIC Educational Resources Information Center

    Wehmeyer, Michael L.

    2003-01-01

    Noting the Governor of Virginia's recent apology for his state's participation in eugenics, this article reviews the history of the sterilization of people with epilepsy and mental retardation in several states, and the importance of the Buck v. Bell (1927) Supreme Court decision in the promotion of eugenics. (Contains references.) (CR)

  1. Advances in Sterilization and Decontamination: a Survey

    NASA Technical Reports Server (NTRS)

    1978-01-01

    Recent technical advances made in the field of sterilization and decontamination and their applicability to private and commercial interests are discussed. Government-sponsored programs by NASA produced the bulk of material presented in this survey. The summary of past and current research discussed is detailed to enhance an effective transfer of technology from NASA to potential users.

  2. Light sterile neutrinos: Status and perspectives

    NASA Astrophysics Data System (ADS)

    Giunti, Carlo

    2016-07-01

    The indications in favor of the existence of light sterile neutrinos at the eV scale found in short-baseline neutrino oscillation experiments is reviewed. The future perspectives of short-baseline neutrino oscillation experiments and the connections with β-decay measurements of the neutrino masses and with neutrinoless double-β decay experiments are discussed.

  3. SPAN - Terminal sterilization process analysis program

    NASA Technical Reports Server (NTRS)

    1969-01-01

    Computer program, SPAN, measures the dry heat thermal sterilization process applied to a planetary capsule and calculates the time required for heat application, steady state conditions, and cooling. The program is based on the logarithmic survival of micro-organisms. Temperature profiles must be input on tape.

  4. SPAN C - Terminal sterilization process analysis program

    NASA Technical Reports Server (NTRS)

    1969-01-01

    Computer program, SPAN-C, measures the dry heat thermal sterilization process applied to a planetary capsule and calculates the time required for heat application, steady state conditions, and cooling. The program is based on the logarithmic survival of micro-organisms. Temperature profiles must be input on cards.

  5. Steam sterilization of air turbine dental handpieces.

    PubMed

    Edwardsson, S; Svensäter, G; Birkhed, D

    1983-12-01

    The efficacy of autoclaving high-speed dental handpieces was tested in two types of downward displacement steam sterilizers (instrument autoclaves), commonly used in the dentist's office. Eight series of experiments were performed with various sterilization schedules. Lubrication oils with or without antimicrobial agent were used in four of the series. Each handpiece was inoculated with 1 ml of a suspension containing equal amounts of saliva and spores of Bacillus stearothermophilus (approx. 10(6) spores/ml). Neither sterilization at 120-124 degrees C for 20 min nor at 134-136 degrees C for 10 min resulted in complete inactivation of the spores in series in which the instruments were tested without oil or with oil containing no antimicrobial agent. However, when the handpieces were lubricated with oil containing isopropanol and formaldehyde and the schedule 134-136 degrees C/10 min was used, no growth was observed. The results indicate that instrument autoclaves with built-in programs of 120-124 degrees C/20 min and 134-136 degrees C/10 min could have insufficient capacity to sterilize lubricated or unlubricated dental handpieces. The use of oils containing an antimicrobial agent can overcome this problem. PMID:6362319

  6. Molecular analysis of cytoplasmic male sterility

    SciTech Connect

    Hanson, M.R.

    1990-01-01

    The ultimate aims of the project are to understand the molecular mechanism of the disruption in pollen development which occurs in cytoplasmic male sterile plants and to understand the control of respiratory energy flow in the higher plant cell. A mitochondrial locus termed S-pcf segregates with sterility and with an alteration in respiration in Petunia. This cloned locus contains three genes, an abnormal fused gene termed pcf, a gene for a subunit of an NADH dehydrogenase complex, and a small ribosomal subunit protein. The pcf gene is comprised of partial sequences of ATPase subunit 9, cytochrome oxidase subunit II, and an unidentified reading frame. Components of the S-Pcf locus will be introduced into the nuclear of a fertile genotype under the control of appropriate regulatory signals, and polypeptide products of introduced genes will be directed to the mitochondrion with a transit peptide. By examining transgenic plants, we can determine what elements of the locus are critical for altered respiration or sterility. Such knowledge could explain how mitochondrial DNA affects pollen development in the large number of plant species which exhibit the agronomically important trait of male sterility. 10 refs., 3 figs.

  7. Light sterile neutrinos after BICEP-2

    SciTech Connect

    Archidiacono, Maria; Hannestad, Steen; Fornengo, Nicolao; Gariazzo, Stefano; Giunti, Carlo; Laveder, Marco E-mail: fornengo@to.infn.it E-mail: giunti@to.infn.it E-mail: marco.laveder@pd.infn.it

    2014-06-01

    The recent discovery of B-modes in the polarization pattern of the Cosmic Microwave Background by the BICEP2 experiment has important implications for neutrino physics. We revisit cosmological bounds on light sterile neutrinos and show that they are compatible with all current cosmological data provided that the mass is relatively low. Using CMB data, including BICEP-2, we find an upper bound of m{sub s} < 0.85 eV (2σ Confidence Level). This bound is strengthened to 0.48 eV when HST measurements of H{sub 0} are included. However, the inclusion of SZ cluster data from the Planck mission and weak gravitational measurements from the CFHTLenS project favours a non-zero sterile neutrino mass of 0.44{sup +0.11}{sub −0.16} eV. Short baseline neutrino oscillations, on the other hand, indicate a new mass state around 1.2 eV. This mass is highly incompatible with cosmological data if the sterile neutrino is fully thermalised (Δχ{sup 2} > 10). However, if the sterile neutrino only partly thermalises it can be compatible with all current data, both cosmological and terrestrial.

  8. Basics of sterile compounding: aseptic processing.

    PubMed

    Akers, Michael J

    2015-01-01

    This article discusses factors that affect the assurance of sterility of an aseptic process operation and balances what is required/practiced in the pharmaceutical industry via the U.S. Food and Drug Administration and European aseptic processing guidelines and what is required/practiced in compounding pharmacies via the United States Pharmacopeia (USP) General Chapter <797>. PMID:25902628

  9. Diluted equilibrium sterile neutrino dark matter

    NASA Astrophysics Data System (ADS)

    Patwardhan, Amol V.; Fuller, George M.; Kishimoto, Chad T.; Kusenko, Alexander

    2015-11-01

    We present a model where sterile neutrinos with rest masses in the range ˜keV to ˜MeV can be the dark matter and be consistent with all laboratory, cosmological, and large-scale structure, as well as x-ray constraints. These sterile neutrinos are assumed to freeze out of thermal and chemical equilibrium with matter and radiation in the very early Universe, prior to an epoch of prodigious entropy generation ("dilution") from out-of-equilibrium decay of heavy particles. In this work, we consider heavy, entropy-producing particles in the ˜TeV to ˜EeV rest-mass range, possibly associated with new physics at high-energy scales. The process of dilution can give the sterile neutrinos the appropriate relic densities, but it also alters their energy spectra so that they could act like cold dark matter, despite relatively low rest masses as compared to conventional dark matter candidates. Moreover, since the model does not rely on active-sterile mixing for producing the relic density, the mixing angles can be small enough to evade current x-ray or lifetime constraints. Nevertheless, we discuss how future x-ray observations, future lepton number constraints, and future observations and sophisticated simulations of large-scale structure could, in conjunction, provide evidence for this model and/or constrain and probe its parameters.

  10. Particulate contamination of sterile syringes and needles.

    PubMed

    Taylor, S A

    1982-08-01

    Commercially available sterile needles and syringes have been examined for particulate contamination using the Hiac light blockage technique. The number of particles delivered was small compared with the total number permitted for large volume parenterals. Where syringes are used in particle counting techniques, the contribution of particles should be taken into account. PMID:6126558

  11. Microwave continuous sterilization of injection ampoules.

    PubMed

    Sasaki, K; Honda, W; Shimizu, K; Iizima, K; Ehara, T; Okuzawa, K; Miyake, Y

    1996-01-01

    A new microwave continuous sterilizer (MWS) for applying microwave dielectric heating as an alternative to an autoclave was developed. The developmental objectives of the MWS were: 1. Achieving sufficient sterilization for the drugs containing heat-sensitive ingredients. 2. Measuring and recording sterilization temperature of each ampoule. 3. Ensuring automatic continuous operation and linkage with the preceding and following machines in an injection ampoule production process. The temperature of the drug solution in an ampoule was heated to 140 degrees C within about 30 seconds by the MWS. Target F0 value is achieved through the maintaining heater to maintain the target temperature for 12 seconds. Ampoules are cooled with air and water after completion of heating. The MWS is capable of processing 150 ampoules per minute. The newly developed techniques which minimized temperature distribution of heated ampoule solution were: 1. Microwave irradiation in a direction opposite to the direction of ampoules transportation. 2. Microwave irradiation in the lower part of ampoule solution (i.e., heating up the drug solution by thermal convection.) 3. Microwave power control by feedback of measured temperatures. 4. Heating rate control corresponding to the dielectric property of ampoule solution. The drug stability test was performed using 3% pyridoxamine phosphate solution, and the inactivation of spores in 3% pyridoxamine phosphate solution was examined using Bacillus stearothermophilus ATCC 7953 spores. The MWS was proved to have an adequate efficiency of sterilization with less chemical degradation of the contents than an autoclave. PMID:8696781

  12. Sterilization Efficiency of Spore forming Bacteria in Powdery Food by Atmospheric Pressure Plasmas Sterilizer

    NASA Astrophysics Data System (ADS)

    Nagata, Masayoshi; Tanaka, Masashi; Kikuchi, Yusuke

    2015-09-01

    To provide food sterilization method capable of killing highly heat resistant spore forming bacteria, we have studied effects of plasma treatment method at atmospheric pressure in order to develop a new high speed plasma sterilization apparatus with a low cost and a high efficiency. It is also difficult even for the plasma treatment to sterilize powdery food including spices such as soybean, basil and turmeric. This paper describes that an introduction of mechanical rotation of a treatment space increases the efficiency so that perfect inactivation of spore forming bacteria in these materials by a short treatment time has been demonstrated in our experiments. We also will discuss the sterilization mechanism by dielectric barrier discharge.

  13. 7 CFR 305.23 - Steam sterilization treatment schedules.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 5 2010-01-01 2010-01-01 false Steam sterilization treatment schedules. 305.23... Steam sterilization treatment schedules. Treatment schedule Temperature( °F) Pressure Exposure period (minutes) Directions T303-b-1 10 lbs 20 Use 28″ vacuum. Steam sterilization is not practical for...

  14. 42 CFR 441.255 - Sterilization by hysterectomy.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Sterilization by hysterectomy. 441.255 Section 441.255 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Sterilizations § 441.255 Sterilization by hysterectomy. (a) FFP is not available in expenditures for...

  15. The Coercive Sterilization of Aboriginal Women in Canada

    ERIC Educational Resources Information Center

    Stote, Karen

    2012-01-01

    This paper considers the coercive sterilization of Aboriginal women in legislated and non-legislated form in Canada. I provide an historical and materialist critique of coercive sterilization. I argue for coercive sterilization to be understood as one of many policies employed to undermine Aboriginal women, to separate Aboriginal peoples from…

  16. 42 CFR 50.207 - Sterilization by hysterectomy.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Sterilization by hysterectomy. 50.207 Section 50... GENERAL APPLICABILITY Sterilization of Persons in Federally Assisted Family Planning Projects § 50.207 Sterilization by hysterectomy. (a) Programs or projects to which this subpart applies shall not perform...

  17. 9 CFR 116.4 - Sterilization and pasteurization -records.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Sterilization and pasteurization... REPORTS § 116.4 Sterilization and pasteurization -records. Records shall be made by means of automatic... ingredients, equipment, or biological product subjected to sterilization or pasteurization. (Approved by...

  18. 21 CFR 872.6710 - Boiling water sterilizer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Boiling water sterilizer. 872.6710 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6710 Boiling water sterilizer. (a) Identification. A boiling water sterilizer is an AC-powered device that consists of a container for boiling...

  19. 21 CFR 522.1484 - Neomycin sulfate sterile solution.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Neomycin sulfate sterile solution. 522.1484... § 522.1484 Neomycin sulfate sterile solution. (a) Specifications. Each milliliter of sterile aqueous solution contains 50 milligrams of neomycin sulfate (equivalent to 35 milligrams of neomycin base).1...

  20. 21 CFR 522.82 - Aminopropazine fumarate sterile solution injection.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Aminopropazine fumarate sterile solution injection... ANIMAL DRUGS § 522.82 Aminopropazine fumarate sterile solution injection. (a) Specifications. Each milliliter of aminopropazine fumarate sterile aqueous solution, veterinary, contains aminopropazine...

  1. 21 CFR 522.1484 - Neomycin sulfate sterile solution.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Neomycin sulfate sterile solution. 522.1484... § 522.1484 Neomycin sulfate sterile solution. (a) Specifications. Each milliliter of sterile aqueous solution contains 50 milligrams of neomycin sulfate (equivalent to 35 milligrams of neomycin base).1...

  2. 21 CFR 522.82 - Aminopropazine fumarate sterile solution injection.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 6 2012-04-01 2012-04-01 false Aminopropazine fumarate sterile solution injection... ANIMAL DRUGS § 522.82 Aminopropazine fumarate sterile solution injection. (a) Specifications. Each milliliter of aminopropazine fumarate sterile aqueous solution, veterinary, contains aminopropazine...

  3. 21 CFR 522.1484 - Neomycin sulfate sterile solution.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 6 2013-04-01 2013-04-01 false Neomycin sulfate sterile solution. 522.1484... § 522.1484 Neomycin sulfate sterile solution. (a) Specifications. Each milliliter of sterile aqueous solution contains 50 milligrams of neomycin sulfate (equivalent to 35 milligrams of neomycin base).1...

  4. 21 CFR 522.82 - Aminopropazine fumarate sterile solution injection.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 6 2013-04-01 2013-04-01 false Aminopropazine fumarate sterile solution injection... ANIMAL DRUGS § 522.82 Aminopropazine fumarate sterile solution injection. (a) Specifications. Each milliliter of aminopropazine fumarate sterile aqueous solution, veterinary, contains aminopropazine...

  5. 21 CFR 522.1484 - Neomycin sulfate sterile solution.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 6 2012-04-01 2012-04-01 false Neomycin sulfate sterile solution. 522.1484... § 522.1484 Neomycin sulfate sterile solution. (a) Specifications. Each milliliter of sterile aqueous solution contains 50 milligrams of neomycin sulfate (equivalent to 35 milligrams of neomycin base).1...

  6. 21 CFR 872.6710 - Boiling water sterilizer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Boiling water sterilizer. 872.6710 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6710 Boiling water sterilizer. (a) Identification. A boiling water sterilizer is an AC-powered device that consists of a container for boiling...

  7. 21 CFR 872.6710 - Boiling water sterilizer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Boiling water sterilizer. 872.6710 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6710 Boiling water sterilizer. (a) Identification. A boiling water sterilizer is an AC-powered device that consists of a container for boiling...

  8. 21 CFR 872.6710 - Boiling water sterilizer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Boiling water sterilizer. 872.6710 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6710 Boiling water sterilizer. (a) Identification. A boiling water sterilizer is an AC-powered device that consists of a container for boiling...

  9. Development of male-sterile lines for breeding hybrid rice

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Rice is a self-pollinated crop that depends on male-sterility for F1 hybrid seed production. As an alternative to accessing existing male-sterile lines from other hybrid breeding programs, the program in Arkansas has created its own novel male-sterile sources. These were developed out of germplasm...

  10. 21 CFR 872.6710 - Boiling water sterilizer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Boiling water sterilizer. 872.6710 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6710 Boiling water sterilizer. (a) Identification. A boiling water sterilizer is an AC-powered device that consists of a container for boiling...

  11. Suppression of Pest Lepidoptera by Releasing Partially Sterile Males

    ERIC Educational Resources Information Center

    Knipling. E. F.

    1970-01-01

    Uses population growth models to calculate the theoretical suppression of reproduction achieved by releasing irradiated male moths carrying genetic sterility factors. Shows that releasing partially sterile males should be more effective than releasing fully sterile males. Discusses the costs and advantages of applying this approach to the control…

  12. 21 CFR 522.1085 - Guaifenesin sterile powder.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Guaifenesin sterile powder. 522.1085 Section 522.1085 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED....1085 Guaifenesin sterile powder. (a) Specifications. It is a sterile powder containing guaifenesin....

  13. 21 CFR 522.1085 - Guaifenesin sterile powder.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Guaifenesin sterile powder. 522.1085 Section 522.1085 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED....1085 Guaifenesin sterile powder. (a) Specifications. It is a sterile powder containing guaifenesin....

  14. 42 CFR 441.255 - Sterilization by hysterectomy.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 4 2012-10-01 2012-10-01 false Sterilization by hysterectomy. 441.255 Section 441... Sterilizations § 441.255 Sterilization by hysterectomy. (a) FFP is not available in expenditures for a hysterectomy if— (1) It was performed solely for the purpose of rendering an individual permanently...

  15. 42 CFR 441.255 - Sterilization by hysterectomy.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 4 2013-10-01 2013-10-01 false Sterilization by hysterectomy. 441.255 Section 441... Sterilizations § 441.255 Sterilization by hysterectomy. (a) FFP is not available in expenditures for a hysterectomy if— (1) It was performed solely for the purpose of rendering an individual permanently...

  16. 42 CFR 441.255 - Sterilization by hysterectomy.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 4 2011-10-01 2011-10-01 false Sterilization by hysterectomy. 441.255 Section 441... Sterilizations § 441.255 Sterilization by hysterectomy. (a) FFP is not available in expenditures for a hysterectomy if— (1) It was performed solely for the purpose of rendering an individual permanently...

  17. 9 CFR 116.4 - Sterilization and pasteurization -records.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 9 Animals and Animal Products 1 2014-01-01 2014-01-01 false Sterilization and pasteurization... REPORTS § 116.4 Sterilization and pasteurization -records. Records shall be made by means of automatic... ingredients, equipment, or biological product subjected to sterilization or pasteurization. (Approved by...

  18. 9 CFR 116.4 - Sterilization and pasteurization -records.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 9 Animals and Animal Products 1 2013-01-01 2013-01-01 false Sterilization and pasteurization... REPORTS § 116.4 Sterilization and pasteurization -records. Records shall be made by means of automatic... ingredients, equipment, or biological product subjected to sterilization or pasteurization. (Approved by...

  19. 9 CFR 116.4 - Sterilization and pasteurization -records.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 9 Animals and Animal Products 1 2012-01-01 2012-01-01 false Sterilization and pasteurization... REPORTS § 116.4 Sterilization and pasteurization -records. Records shall be made by means of automatic... ingredients, equipment, or biological product subjected to sterilization or pasteurization. (Approved by...

  20. 9 CFR 116.4 - Sterilization and pasteurization -records.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false Sterilization and pasteurization... REPORTS § 116.4 Sterilization and pasteurization -records. Records shall be made by means of automatic... ingredients, equipment, or biological product subjected to sterilization or pasteurization. (Approved by...

  1. Orthodontic instrument sterilization with microwave irradiation

    PubMed Central

    Yezdani, Arif; Mahalakshmi, Krishnan; Padmavathy, Kesavaram

    2015-01-01

    Objective: This study was designed to evaluate the efficiency of microwave sterilization of orthodontic instruments and molar bands immersed in plain distilled water with and without oral rinse, and to ascertain the minimum time of exposure required to sterilize. Materials and Methods: The orthodontic instruments (hinged and nonhinged), molar bands and mouth mirrorsused in the patient 's mouth were selected for the study. The instruments were divided into two groups – Group I with oral rinse-set A (0.01% chlorhexidine gluconate) and set B (0.025% betadine) and Group II (included sets C and D without oral rinse). The instruments of set A, B and C were microwaved at 2,450 MHz, 800 W for 5 min, whereas, set D was microwaved for 10 min at the same above mentioned specifications. The efficacy of sterilization was assessed by stab inoculation of the instruments onto trypticase soya agar plates. The plates were checked for bacterial growth following incubation at 37 °C for 24 h. For sterility control,Geobacillus stearothermophilus (MTCC 1518) was included. Results: No growth was observed in the plates that were inoculated with the microwaved orthodontic instruments of sets A, B and D, whereas scanty bacterial growth was observed in the plates inoculatedwith the microwaved set C instruments. Conclusion: Effective sterilization was achieved when the orthodontic instruments and molar bands were immersed in distilled water without oral rinse and microwaved for 10 min as also for those that were immersed in distilled water with oral rinse and microwaved for 5 min. PMID:26015686

  2. Device and Container for Reheating and Sterilization

    NASA Technical Reports Server (NTRS)

    Sastry, Sudhir K.; Heskitt, Brian F.; Jun, Soojin; Marcy, Joseph E.; Mahna, Ritesh

    2012-01-01

    Long-duration space missions require the development of improved foods and novel packages that do not represent a significant disposal issue. In addition, it would also be desirable if rapid heating technologies could be used on Earth as well, to improve food quality during a sterilization process. For this purpose, a package equipped with electrodes was developed that will enable rapid reheating of contents via ohmic heating to serving temperature during space vehicle transit. Further, the package is designed with a resealing feature, which enables the package, once used, to contain and sterilize waste, including human waste for storage prior to jettison during a long-duration mission. Ohmic heating is a technology that has been investigated on and off for over a century. Literature indicates that foods processed by ohmic heating are of superior quality to their conventionally processed counterparts. This is due to the speed and uniformity of ohmic heating, which minimizes exposure of sensitive materials to high temperatures. In principle, the material may be heated rapidly to sterilization conditions, cooled rapidly, and stored. The ohmic heating device herein is incorporated within a package. While this by itself is not novel, a reusable feature also was developed with the intent that waste may be stored and re-sterilized within the packages. These would then serve a useful function after their use in food processing and storage. The enclosure should be designed to minimize mass (and for NASA's purposes, Equivalent System Mass, or ESM), while enabling the sterilization function. It should also be electrically insulating. For this reason, Ultem high-strength, machinable electrical insulator was used.

  3. Thermal sterilization of heat-sensitive products using high-temperature short-time sterilization.

    PubMed

    Mann, A; Kiefer, M; Leuenberger, H

    2001-03-01

    High-temperature short-time (HTST) sterilization with a continuous-flow sterilizer, developed for this study, was evaluated. The evaluation was performed with respect to (a) the chemical degradation of two heat-sensitive drugs in HTST range (140-160 degrees C) and (b) the microbiological effect of HTST sterilization. Degradation kinetics of two heat-sensitive drugs showed that a high peak temperature sterilization process resulted in less chemical degradation for the same microbiological effect than a low peak temperature process. Both drugs investigated could be sterilized with acceptable degradation at HTST conditions. For the evaluation of the microbiological effect, Bacillus stearothermophilus ATCC 7953 spores were used as indicator bacteria. Indicator spore kinetics (D(T), z value, k, and E(a)), were determined in the HTST range. A comparison between the Bigelow model (z value concept) and the Arrhenius model, used to describe the temperature coefficient of the microbial inactivation, demonstrated that the Bigelow model is more accurate in prediction of D(T) values in the HTST range. The temperature coefficient decreased with increasing temperature. The influence of Ca(2+) ions and pH value on the heat resistance of the indicator spores, which is known under typical sterilization conditions, did not change under HTST conditions. PMID:11170021

  4. Coelioscopic and Endoscope-Assisted Sterilization of Chelonians.

    PubMed

    Proença, Laila M; Divers, Stephen J

    2015-09-01

    Elective sterilization is a safe and well-established surgical procedure performed in dogs and cats worldwide. Conversely, chelonian sterilization has been mostly performed therapeutically, because of the intricate anatomy and difficult access to the reproductive organs, and consequently, reproductive problems and diseases remain common. With the advance of veterinary endoscopy, novel techniques of soft tissue prefemoral coelioscopic and endoscope-assisted sterilization have been published, and preventative chelonian sterilization is now a reality. Nevertheless, extrapolations between species should be carefully considered, and further studies are warranted. This article summarizes and describes the current coelioscopic and coelioscope-assisted sterilization techniques for chelonia. PMID:26336003

  5. Bounds on sterile neutrino parameters from reactor experiments

    NASA Astrophysics Data System (ADS)

    Bora, Kalpana

    2014-03-01

    In this work, we present a realistic analysis of the potential of the present-day reactor experiments Double Chooz, Daya Bay and RENO for probing the existence of sterile neutrinos. We present exclusion regions for sterile oscillation parameters and find that these experimental set-ups give significant bounds on the parameter Θee especially in the low sterile oscillation region 0.01 < Δm241 < 0.05 eV2. These bounds can add to our understanding of the sterile neutrino sector since there is still a tension in the allowed regions from different experiments for sterile parameters.

  6. Modelling releases of sterile mosquitoes with different strategies.

    PubMed

    Li, Jia; Yuan, Zhiling

    2015-01-01

    To prevent the transmissions of malaria, dengue fever, or other mosquito-borne diseases, one effective weapon is the sterile insect technique in which sterile mosquitoes are released to reduce or eradicate the wild mosquito population. To study the impact of the sterile insect technique on disease transmission, we formulate discrete-time mathematical models, based on difference equations, for the interactive dynamics of the wild and sterile mosquitoes, incorporating different strategies in releasing sterile mosquitoes. We investigate the model dynamics and compare the impact of the different release strategies. Numerical examples are given to demonstrate rich dynamical features of the models. PMID:25377433

  7. Sterilization of dental instruments and devices: an update.

    PubMed

    Goodman, H S; Carpenter, R D; Cox, M R

    1994-04-01

    Dental sterilization techniques have become a focus of attention as a result of disclosure of occupational HIV transmission from an infected dentist to a cluster of patients. Although there has never been a confirmed report of a patient acquiring an infectious blood-borne disease from a dental instrument or device, recommendations for universal sterilization of dental handpieces and other devices have recently been implemented. Because of the higher rate of hepatitis B virus transmissability in the dental health care environment, an upgrade in sterilization protocols may be warranted. Stringent sterilization standards are especially necessary in higher-risk institutional dental care settings. However, a high rate of dental sterilization errors has been reported and traced to operator error. Recent institutional dental sterilization policy changes have been developed to reduce the chance of sterilization error, further diminishing the risk of cross contamination. PMID:8060010

  8. The sterilization efficacy of reprocessed single use diathermy pencils.

    PubMed

    Batista Neto, Simone; Graziano, Kazuko Uchikawa; Padoveze, Maria Clara; Kawagoe, Júlia Yaeko

    2010-01-01

    In Brazil, single use diathermy pencils (SUDP) are among the most common reused devices. This study assesses the sterilization efficacy of reprocessing SUDP using two cleansing methods (manual or automated), followed by one of three of the low-temperature sterilization methods: Hydrogen Peroxide Plasma (HPP), Ethylene Oxide (ETO) or Low-Temperature Steam Formaldehyde (LTSF). The sample was composed of 360 SUDP after their first use. The probability of sterilization failure was estimated considering the number of positive microbiological results obtained by cultures of the studied devices. The overall sterilization failure probability for SUDP was 0.26. The sterilization method, which presented the lowest failure probability was the LTSF (0.01), followed by ETO (0.21) and HPP (0.56). Automated cleansing obtained a better result than manual cleansing. This trial demonstrated that the probability of sterilization in reprocessed SUDP is highly dependent on both the type of cleansing and the sterilization method applied. PMID:20428701

  9. Daughters mimic sterile neutrinos (almost!) perfectly

    NASA Astrophysics Data System (ADS)

    Hasenkamp, Jasper

    2014-09-01

    Since only recently, cosmological observations are sensitive to hot dark matter (HDM) admixtures with sub-eV mass, mhdmeff < eV, that are not fully-thermalised, Δ Neff < 1. We argue that their almost automatic interpretation as a sterile neutrino species is neither from theoretical nor practical parsimony principles preferred over HDM formed by decay products (daughters) of an out-of-equilibrium particle decay. While daughters mimic sterile neutrinos in Neff and mhdmeff, there are opportunities to assess this possibility in likelihood analyses. Connecting cosmological parameters and moments of momentum distribution functions, we show that—also in the case of mass-degenerate daughters with indistinguishable main physical effects—the mimicry breaks down when the next moment, the skewness, is considered. Predicted differences of order one in the root-mean-squares of absolute momenta are too small for current sensitivities.

  10. A Sterile Robotic Mars Soil Analyzer

    NASA Technical Reports Server (NTRS)

    Levin, Gilbert V.; Miller, Joseph D.; Straat, Patricia Ann; Hoover, Richard E.

    2002-01-01

    Since the 1976 Viking Mission to Mars, follow-on efforts to resolve its controversial life detection results have been thwarted by two heretofore insurmountable difficulties: the huge expense of sterilizing the entire spacecraft to protect the integrity of life detection experiments; and the lack of a practical robotic life detection package that could produce results acceptable as unambiguous by the scientific community. We here present a method that assures sterility and the complete integrity of robotic life detection experiments, all at a negligible cost. Second, we propose a candidate set of integrated, highly sensitive experiments that we believe could produce results acceptable to the vast majority of scientists. In addition to the biology-chemistry issue, the extensively debated oxidative state of the Martian surface and other chemical and physical characteristics of the Martian soil would be determined. We present our concept for a miniaturized instrument that could carry out a number of candidate experiments to achieve the objective.

  11. Surgical sterilization of free-ranging wolves.

    PubMed Central

    Spence, C E; Kenyon, J E; Smith, D R; Hayes, R D; Baer, A M

    1999-01-01

    The objective of the study was to determine whether surgical sterilization of both males and females in wolf pairs alters basic wolf social and territorial behaviors. Wolves were located from the air by snow-tracking methods and were tranquilizer-darted from a helicopter. Surgeries were performed either in a tent at the capture site or in a heated building in a nearby village. Six vasectomies and seven uterine horn ligations were performed in January and February of 1996 and 1997. Two females died: one likely related to the capture procedure, the other of a peritonitis unrelated to the surgery. One wolf had a litter. None of the wolves have shown changes in behavioral patterns. Surgical sterilization can be effective, but other, less invasive, fertility control techniques should be investigated. PMID:10065320

  12. A search for sterile neutrinos in MINOS

    SciTech Connect

    Osiecki, Thomas Henry; /Texas U.

    2007-12-01

    MINOS, the Main Injector Neutrino Oscillation Search, is a long baseline neutrino oscillation experiment based at Fermilab National Accelerator Laboratory. The experiment uses a neutrino beam, which is measured 1 km downstream from its origin in the Near detector at Fermilab and then 735 km later in the Far detector at the Soudan mine. By comparing these two measurements, MINOS can attain a very high precision for parameters in the atmospheric sector of neutrino oscillations. In addition to precisely determining {Delta}m{sub 23}{sup 2} and {theta}{sub 23} through the disappearance of {nu}{sub {mu}}, MINOS is able to measure {nu}{sub {mu}} {yields} {nu}{sub sterile} by looking for a deficit in the number of neutral current interactions seen in the Far detector. In this thesis, we present the results of a search for sterile neutrinos in MINOS.

  13. How well does the Chemiclave sterilize handpieces?

    PubMed

    Kolstad, R A

    1998-07-01

    Using the Food and Drug Administration's protocol for testing health care sterilizers, the author investigated the ability of chemical vapor and steam to sterilize handpieces. Five internal sites of six high-speed handpiece models and four internal positions of one low-speed handpiece model were each inoculated with 10(6) Bacillus stearothermophilus spores. Half-cycle challenges were conducted with Chemiclave models EC 5500 and 8000 (Barnstead/Thermolyne) and with two autoclaves, Tuttnauer 2540M (large chamber) (Tuttnauer USA Co., Ltd.) and Statim Cassette (SciCan USA). Experiments with spores either openly exposed or partially enclosed prove that chemical vapor is an excellent lethal agent, but strongly suggest penetration weakness [corrected]. PMID:9685763

  14. Gas dynamics of ethylene oxide during sterilization

    NASA Astrophysics Data System (ADS)

    Zhu, Z.; Matthews, I. P.; Wang, C.

    1999-07-01

    This article reports a case study of the dynamics of ethylene oxide gas during sterilization using a microwave spectrometer. A diffusion equation is used to describe the processes of gas penetration, gas sorption, and chemical reactions. The three processes, although mathematically related, may be solved separately under simplified assumptions. This permits the prediction of gas penetration and sorption as well as the effect of chemical reactions upon the gas concentration for loads of differing dimensions and densities.

  15. Fertility following reversal of female sterilization.

    PubMed

    Rachagan, S P; Jaafar, Y

    1993-06-01

    This retrospective study presents data from 26 women who underwent a reversal of female sterilization. The intrauterine pregnancy rate and ectopic pregnancy rate were 38.5% and 7.7% respectively. The most successful site of tubal anastomosis was isthmic-isthmic anastomosis. The importance of proper patient selection and factors that affect the success rate in attempted reversals are emphasised. The importance of microsurgical approach is highlighted. PMID:8350801

  16. Sterile neutrinos in the early universe

    SciTech Connect

    Malaney, R.A. ); Fuller, G.M. . Dept. of Physics)

    1990-11-14

    We discuss the role played by right-handed sterile neutrinos in the early universe. We show how well known {sup 4}He constraint on the number of relativistic degrees of freedom at early times limits the equilibration of the right handed neutrino sea with the background plasma. We discuss how this allows interesting constraints to be placed on neutrino properties. In particular, a new limit on the Dirac mass of the neutrino is presented. 12 refs.

  17. Bone banking and sterilization of bones

    NASA Astrophysics Data System (ADS)

    Minamisawa, I.; Itoman, M.; Maehara, H.; Kobayashi, A.; Watanabe, T.

    1995-08-01

    The use of banked bone (preserved allograft bone) is various and essential, because it has numerous advantages including the relative ease in retrieval a large amount of bone material and requisite shape and size. But bone banking and allografting must be promoted under obligation to stably supply safe and high-quality bone. To avoid transferring disease perfectly, irradiation sterilization is especially recommended at the present time.

  18. [Principles of antisepsis, disinfection and sterilization].

    PubMed

    Hernández-Navarrete, María-Jesús; Celorrio-Pascual, José-Miguel; Lapresta Moros, Carlos; Solano Bernad, Victor-Manuel

    2014-12-01

    This article aims to provide a brief review of the main concepts on which the prevention and control of infection are based. Antisepsis comprises a set of techniques aimed at the total sterilization, or at most, disinfection, removing germs that contaminate an environment. Both procedures must be preceded by an environmental cleanup in the location in which they intend to be applied. The disinfection is carried out using biocides or germicides. Antimicrobial chemicals, that have mechanisms of action and resistances very similar to antibiotics, are generating concern due to the possibility of crossing genetic information that aggravates the problem of bacterial resistance. Most biocides can act as antiseptics, and applied to skin tissue, or disinfectants on inanimate materials. The spectrum of action of germicides depends on the product itself and external controllable factors: temperature, concentration, exposure time, etc. Sterilization techniques are primarily physical, by exposing the material to steam, or sterilizing gas, using autoclaves. Major advances are the use of low temperatures with shorter exposure times, in parallel with technological advances in instrumentation in order to avoid high temperatures and high use rotations due to workload. PMID:25023372

  19. Sterile neutrinos as subdominant warm dark matter

    SciTech Connect

    Palazzo, A.; Cumberbatch, D.; Slosar, A.; Silk, J.

    2007-11-15

    In light of recent findings which seem to disfavor a scenario with (warm) dark matter entirely constituted of sterile neutrinos produced via the Dodelson-Widrow mechanism, we investigate the constraints attainable for this mechanism by relaxing the usual hypothesis that the relic neutrino abundance must necessarily account for all of the dark matter. We first study how to reinterpret the limits attainable from x-ray nondetection and Lyman-{alpha} forest measurements in the case that sterile neutrinos constitute only a fraction f{sub s} of the total amount of dark matter. Then, assuming that sterile neutrinos are generated in the early universe solely through the Dodelson-Widrow mechanism, we show how the x-ray and Lyman-{alpha} results jointly constrain the mass-mixing parameters governing their production. Furthermore, we show how the same data allow us to set a robust upper limit f{sub s} < or approx. 0.7 at the 2{sigma} level, rejecting the case of dominant dark matter (f{sub s}=1) at the {approx}3{sigma} level.

  20. [Defective function of bioindicators for steam sterilization].

    PubMed

    Botzenhart, K; Merkt-Kinzler, M

    1990-05-01

    It can be shown, that under certain conditions commercially available indicators with Bacillus stearothermophilus and packages of native spores from soil prepared according to DIN 58 946/4 react differently to treatment in a lab-type steam sterilizer. The differences were most evident when incomplete evacuation of air had to be supposed. These results lead to the conclusion that some bioindicators are not able to show the inefficient function of steam sterilizers caused by local residuals of air. This may be caused by the properties of the selected strain, by the conditions of growth and preparation of the spores and by the culture medium used after exposition. The results of our experiments as well as the resistance of mesophilic spore forming bacilli against dry heat described by other authors make it necessary to test the resistance of bioindicators for steam sterilization not only against steam according to DIN 58946/4 but also against dry heat or mixtures of steam and air. PMID:2393488

  1. Surgical sterilization: an underutilized procedure for evaluating the merits of induced sterility

    USGS Publications Warehouse

    Kennelly, James J.; Converse, Kathryn A.

    1993-01-01

    Despite more than 4 decades of effort, development of effective wildlife damage control programs based on sterilization of target species has met with limited success. This is partly due to the fact that investigators have assumed, rather than empirically tested, whether the reproductive strategies of the target populations were vulnerable to the planned treatment. Equally important, methods selected to include sterility usually involve a chemical agent that can affect sociosexual behaviors of the nuisance population. In this report, we illustrate how surgically induced sterility circumvents both problems--how the concept without the potentially confounding secondary effects of a chemical. We assessed the merits of initiating research to develop a male chemosterilant for Norway rats, red-winged blackbirds, beaver, and Canada geese by inducing sterility surgically. The infidelity of many red-winged females to their polygynous territorial male was surprising and argued against searching for a male sterilant. On the other hand, beaver and Canada goose studies confirmed previous reports that both form par-bonds and are monogamous. Both should be vulnerable to a male chemosterilant approach, and research toward this goal is justified.

  2. Sterile Insect Technique and F1 Sterility in the European Grapevine Moth, Lobesia botrana

    PubMed Central

    Saour, George

    2014-01-01

    Newly emerged adults of the European grapevine moth, Lobesia botrana (Denis and Schiffermuller) (Lepidoptera: Tortricidae), were irradiated with various doses of gamma radiation and crossed to unirradiated counterparts of the opposite sex. Fecundity was decreased when unirradiated females were mated with either 300- or 350-Gy-irradiated males. Adult males that were irradiated with 400 Gy and mated with unirradiated females retained a residual fertility of 2.7%. The radiation dose at which irradiated females were found to be 100% sterile when mated with unirradiated males was 150 Gy. The inherited effects in the F1 progeny of irradiated male parents were examined at 100, 150, and 200 Gy. Fecundity and fertility of the F1 progeny of males irradiated with 150 Gy and inbred or crossed with irradiated and unirradiated moths were also recorded. A significant reduction in fertility was observed when F1 males mated with either F1 or unirradiated females. According to sterility index, F1 females who mated with F1 males had greater sterility than when F1 females were crossed to 150-Gy-irradiated males. Based upon the results of this study, 150 Gy of gamma radiation would be the optimal dose to use in a sterile insect technique and F1 sterility program against L. botrana. PMID:25373155

  3. Sterile insect technique and F₁ sterility in the European grapevine moth, Lobesia botrana.

    PubMed

    Saour, George

    2014-01-01

    Newly emerged adults of the European grapevine moth, Lobesia botrana (Denis and Schiffermuller) (Lepidoptera: Tortricidae), were irradiated with various doses of gamma radiation and crossed to unirradiated counterparts of the opposite sex. Fecundity was decreased when unirradiated females were mated with either 300-or 350-Gy-irradiated males. Adult males that were irradiated with 400 Gy and mated with unirradiated females retained a residual fertility of 2.7%. The radiation dose at which irradiated females were found to be 100% sterile when mated with unirradiated males was 150 Gy. The inherited effects in the F1 progeny of irradiated male parents were examined at 100, 150, and 200 Gy. Fecundity and fertility of the F1 progeny of males irradiated with 150 Gy and inbred or crossed with irradiated and unirradiated moths were also recorded. A significant reduction in fertility was observed when F1 males mated with either F1 or unirradiated females. According to sterility index, F1 females who mated with F1 males had greater sterility than when F1 females were crossed to 150-Gy-irradiated males. Based upon the results of this study, 150 Gy of gamma radiation would be the optimal dose to use in a sterile insect technique and F1 sterility program against L. botrana. PMID:25373155

  4. Degradation of chitosan-based materials after different sterilization treatments

    NASA Astrophysics Data System (ADS)

    San Juan, A.; Montembault, A.; Gillet, D.; Say, J. P.; Rouif, S.; Bouet, T.; Royaud, I.; David, L.

    2012-02-01

    Biopolymers have received in recent years an increasing interest for their potential applications in the field of biomedical engineering. Among the natural polymers that have been experimented, chitosan is probably the most promising in view of its exceptional biological properties. Several techniques may be employed to sterilize chitosan-based materials. The aim of our study was to compare the effect of common sterilization treatments on the degradation of chitosan-based materials in various physical states: solutions, hydrogels and solid flakes. Four sterilization methods were compared: gamma irradiation, beta irradiation, exposure to ethylene oxide and saturated water steam sterilization (autoclaving). Exposure to gamma or beta irradiation was shown to induce an important degradation of chitosan, regardless of its physical state. The chemical structure of chitosan flakes was preserved after ethylene oxide sterilization, but this technique has a limited use for materials in the dry state. Saturated water steam sterilization of chitosan solutions led to an important depolymerization. Nevertheless, steam sterilization of chitosan flakes bagged or dispersed in water was found to preserve better the molecular weight of the polymer. Hence, the sterilization of chitosan flakes dispersed in water would represent an alternative step for the preparation of sterilized chitosan solutions. Alternatively, autoclaving chitosan physical hydrogels did not significantly modify the macromolecular structure of the polymer. Thus, this method is one of the most convenient procedures for the sterilization of physical chitosan hydrogels after their preparation.

  5. Some aspects of the sterilization program in Malaysia.

    PubMed

    Arshat, H; Ali, J; Noor Laily Abu Bakar

    1984-06-01

    Sterilization is most often indicated when the desired family size is reached and no more children are desired. Because of technical advances and societal changes surgical sterilization is increasingly becoming the most utilized method of contraception. Since female sterilization is more common, several methods have been devised to make it safe and reliable. The traditional large abdominal incision (laparotomy) is now replaced by minilaparotomy, which is a small abdominal incision. Other techniques, such as transvaginal and trancervical approaches require no incision at all. These method permit occlusion of any part of the fallopian tube. Minilapatomy is the recommended method of female sterilization for 3rd world countries. Laparoscopic sterilization appears to be more psychologically acceptable to 3rd world women who have an inherent dread of surgery. A higher incidence of hematoma formation has been reported in puerperal laparoscopic sterilizations and the failure rate is also higher than in other methods. Other complications associated with laparoscopic sterilization include wound sepsis, surgical emphysema of the parieties and uterine perforation. Laparoscopic sterilizations can be performed under local, general, spinal or epidural anesthesia. Local and general anesthesia is the commonest. Both tubal ligations and vasectomies have been available in Malaysia since the 1960s. Laparoscopy was 1st introduced in Malaysia in the early 1970s. Several laparoscopy centers have been established in Malaysia to provide specialized family planning services. Outpatient laparoscopic sterilization is a feature of the Kuala Lumpur Specialist Center. Traditonally doctors and specialists in Malaysia received their practical training in sterilization techniques during their internship or residency. Since 1980, however, a formal training program was initiated. Because laparoscopy provides interval sterilization without major abdominal surgery, this procedure has played a major

  6. Sporicidal activity of a new low-temperature sterilization technology: the Sterrad 50 sterilizer.

    PubMed

    Rutala, W A; Gergen, M F; Weber, D J

    1999-07-01

    This study was undertaken to evaluate the efficacy of a new low-temperature sterilization system that recently has been cleared by the Food and Drug Administration, the Sterrad 50. Flat stainless steel carriers were inoculated with approximately 10(6) Bacillus stearothermophilus spores. These carriers were placed aseptically in the middle of 40-cm-long stainless steel-lumened test units of varying diameters (1 mm, 2 mm, and 3 mm). After inoculation, the test units were processed in the Sterrad 50. After sterilization, the carriers were assayed for growth of the B. stearothermophilus spores. Our data demonstrated that the Sterrad 50 was highly effective in killing the B. stearothermophilus spores (no positive carriers with 30 tests of each lumen-diameter test unit). The Sterrad 50 is likely to be clinically useful for the sterilization of heat-sensitive medical equipment. PMID:10432166

  7. Condom Use among Sterilized and Non-sterilized Women in County Jail and Residential Treatment Centers

    PubMed Central

    Pruitt, Sandi L.; von Sternberg, Kirk; Velasquez, Mary M.; Mullen, Patricia Dolan

    2010-01-01

    Purpose While sterilized women do not need condoms for pregnancy prevention, they may still be at risk for sexually transmitted infections (STIs). Previous studies have shown that sterilized women have lower rates of condom use but have not controlled for the nested multilevel structure of data in which individual women have multiple partners with different STI risk factors. We address this limitation by testing the association of condom use and tubal ligation using multilevel analysis. Methods Data were obtained from a cross-sectional survey of sterilized and non-sterilized women aged 18–44 in substance abuse treatment centers or county jail. Multilevel random intercept logistic models examined the association of tubal ligation and any condom use in the 30 days prior to entry and controlled for individual- and partner- level correlates. Findings Of 484 pre-menopausal respondents without hysterectomy, 194 (40.1%) reported tubal ligation. Overall, 48.3% of all women reported any condom use. In unadjusted and adjusted analyses, sterilized women were less likely to report any condom use. Women were least likely to use condoms with their main partners and more likely to use condoms with other partners and partners with whom they trade sex for drugs or money. Women were also more likely to use condoms with partners they believed to be HIV positive. Conclusion In these high-risk settings, we found a high prevalence of women reporting tubal ligation and lower odds of condom use among these women. Condom use interventions targeting sterilized women in these settings are needed. PMID:20880718

  8. Comparative Transcriptome Analysis of Recessive Male Sterility (RGMS) in Sterile and Fertile Brassica napus Lines

    PubMed Central

    Zhao, Huiyan; Liu, Chuan; Li, Jiana; Tang, Zhanglin; Xu, Xinfu; Qiu, Xiao; Wang, Rui; Lu, Kun

    2015-01-01

    The recessive genetic male sterility (RGMS) system plays a key role in the production of hybrid varieties in self-pollinating B. napus plants, and prevents negative cytoplasmic effects. However, the complete molecular mechanism of the male sterility during male-gametogenesis in RGMS remains to be determined. To identify transcriptomic changes that occur during the transition to male sterility in RGMS, we examined the male sterile line WSLA and male fertile line WSLB, which are near-isogenic lines (NILs) differing only in the fertility trait. We evaluated the phenotypic features and sterility stage using anatomical analysis. Comparative RNA sequencing analysis revealed that 3,199 genes were differentially expressed between WSLA and WSLB. Many of these genes are mainly involved in biological processes related to flowering, including pollen tube development and growth, pollen wall assembly and modification, and pollen exine formation and pollination. The transcript profiles of 93 genes associated with pollen wall and anther development were determined by quantitative RT-PCR in different flower parts, and classified into the following three major clades: 1) up-regulated in WSLA plants; 2) down-regulated in WSLA plants; and 3) down-regulated in buds, but have a higher expression in stigmas of WSLA than in WSLB. A subset of genes associated with sporopollenin accumulation were all up-regulated in WSLA. An excess of sporopollenin results in defective pollen wall formation, which leads to male sterility in WSLA. Some of the genes identified in this study are candidates for future research, as they could provide important insight into the molecular mechanisms underlying RGMS in WSLA. PMID:26656530

  9. Comparative Transcriptome Analysis of Recessive Male Sterility (RGMS) in Sterile and Fertile Brassica napus Lines.

    PubMed

    Qu, Cunmin; Fu, Fuyou; Liu, Miao; Zhao, Huiyan; Liu, Chuan; Li, Jiana; Tang, Zhanglin; Xu, Xinfu; Qiu, Xiao; Wang, Rui; Lu, Kun

    2015-01-01

    The recessive genetic male sterility (RGMS) system plays a key role in the production of hybrid varieties in self-pollinating B. napus plants, and prevents negative cytoplasmic effects. However, the complete molecular mechanism of the male sterility during male-gametogenesis in RGMS remains to be determined. To identify transcriptomic changes that occur during the transition to male sterility in RGMS, we examined the male sterile line WSLA and male fertile line WSLB, which are near-isogenic lines (NILs) differing only in the fertility trait. We evaluated the phenotypic features and sterility stage using anatomical analysis. Comparative RNA sequencing analysis revealed that 3,199 genes were differentially expressed between WSLA and WSLB. Many of these genes are mainly involved in biological processes related to flowering, including pollen tube development and growth, pollen wall assembly and modification, and pollen exine formation and pollination. The transcript profiles of 93 genes associated with pollen wall and anther development were determined by quantitative RT-PCR in different flower parts, and classified into the following three major clades: (1) up-regulated in WSLA plants; (2) down-regulated in WSLA plants; and 3) down-regulated in buds, but have a higher expression in stigmas of WSLA than in WSLB. A subset of genes associated with sporopollenin accumulation were all up-regulated in WSLA. An excess of sporopollenin results in defective pollen wall formation, which leads to male sterility in WSLA. Some of the genes identified in this study are candidates for future research, as they could provide important insight into the molecular mechanisms underlying RGMS in WSLA. PMID:26656530

  10. Social and psychological perspectives on voluntary sterilization: a review.

    PubMed

    Philliber, S G; Philliber, W W

    1985-01-01

    This paper reviews social science research on the antecedents and consequences of voluntary sterilization. The major conclusions are that socioeconomic status has little impact on the decision to be sterilized and that sterilizations are rare among those without sons and among male non-whites. Significant others are important sources of encouragement and information, and good marital relations increase the likelihood of having the procedure performed. Most acceptors experience no change in sexual activity, quality of marital relationships, or work-related behavior, and few regret their choice. Negative consequences are more likely among those in India, those coerced into having a sterilization, those who did not understand the consequences of the procedure, those with health complications after sterilization, and those couples who have unstable marriages or who disagree about sterilization. PMID:3983979