Sample records for ihc staining showed

  1. AutoIHC-scoring: a machine learning framework for automated Allred scoring of molecular expression in ER- and PR-stained breast cancer tissue.

    PubMed

    Tewary, S; Arun, I; Ahmed, R; Chatterjee, S; Chakraborty, C

    2017-11-01

    In prognostic evaluation of breast cancer Immunohistochemical (IHC) markers namely, oestrogen receptor (ER) and progesterone receptor (PR) are widely used. The expert pathologist investigates qualitatively the stained tissue slide under microscope to provide the Allred score; which is clinically used for therapeutic decision making. Such qualitative judgment is time-consuming, tedious and more often suffers from interobserver variability. As a result, it leads to imprecise IHC score for ER and PR. To overcome this, there is an urgent need of developing a reliable and efficient IHC quantifier for high throughput decision making. In view of this, our study aims at developing an automated IHC profiler for quantitative assessment of ER and PR molecular expression from stained tissue images. We propose here to use CMYK colour space for positively and negatively stained cell extraction for proportion score. Also colour features are used for quantitative assessment of intensity scoring among the positively stained cells. Five different machine learning models namely artificial neural network, Naïve Bayes, K-nearest neighbours, decision tree and random forest are considered for learning the colour features using average red, green and blue pixel values of positively stained cell patches. Fifty cases of ER- and PR-stained tissues have been evaluated for validation with the expert pathologist's score. All five models perform adequately where random forest shows the best correlation with the expert's score (Pearson's correlation coefficient = 0.9192). In the proposed approach the average variation of diaminobenzidine (DAB) to nuclear area from the expert's score is found to be 7.58%, as compared to 27.83% for state-of-the-art ImmunoRatio software. © 2017 The Authors Journal of Microscopy © 2017 Royal Microscopical Society.

  2. Correlation of IHC and FISH for ALK gene rearrangement in non-small cell lung carcinoma: IHC score algorithm for FISH.

    PubMed

    Yi, Eunhee S; Boland, Jennifer M; Maleszewski, Joseph J; Roden, Anja C; Oliveira, Andre M; Aubry, Marie-Christine; Erickson-Johnson, Michele R; Caron, Bolette L; Li, Yan; Tang, Hui; Stoddard, Shawn; Wampfler, Jason; Kulig, Kimary; Yang, Ping

    2011-03-01

    Accurate, cost-effective methods for testing anaplastic lymphoma kinase gene rearrangement (ALK+) are needed to select patients with non-small cell lung carcinoma for ALK-inhibitor therapy. Fluorescent in situ hybridization (FISH) is used to detect ALK+, but it is expensive and not routinely available. We explored the potential of an immunohistochemistry (IHC) scoring system as an affordable, accessible approach. One hundred one samples were obtained from an enriched cohort of never-smokers with adenocarcinoma from the Mayo Clinic Lung Cancer Cohort. IHC was performed using the ALK1 monoclonal antibody with ADVANCE detection system (Dako) and FISH with dual-color, break-apart probe (Abbott Molecular) on formalin-fixed, paraffin-embedded tissue. Cases were assessed as IHC score 0 (no staining; n = 69), 1+ (faint cytoplasmic staining, n = 21), 2+ (moderate, smooth cytoplasmic staining; n = 3), or 3+ (intense, granular cytoplasmic staining in ≥10% of tumor cells; n = 8). All IHC 3+ cases were FISH+, whereas 1 of 3 IHC 2+ and 1 of 21 IHC 1+ cases were FISH+. All 69 IHC 0 cases were FISH-. Considering FISH a gold-standard reference in this study, sensitivity and specificity of IHC were 90 and 97.8%, respectively, when 2+ and 3+ were regarded as IHC positive and 0 and 1+ as IHC negative. IHC scoring correlates with FISH and may be a useful algorithm in testing ALK+ by FISH in non-small cell lung carcinoma, similar to human epidermal growth factor-2 testing in breast cancer. Further study is needed to validate this approach.

  3. Proposals for best-quality immunohistochemical staining of paraffin-embedded brain tissue slides in forensics.

    PubMed

    Trautz, Florian; Dreßler, Jan; Stassart, Ruth; Müller, Wolf; Ondruschka, Benjamin

    2018-01-03

    Immunohistochemistry (IHC) has become an integral part in forensic histopathology over the last decades. However, the underlying methods for IHC vary greatly depending on the institution, creating a lack of comparability. The aim of this study was to assess the optimal approach for different technical aspects of IHC, in order to improve and standardize this procedure. Therefore, qualitative results from manual and automatic IHC staining of brain samples were compared, as well as potential differences in suitability of common IHC glass slides. Further, possibilities of image digitalization and connected issues were investigated. In our study, automatic staining showed more consistent staining results, compared to manual staining procedures. Digitalization and digital post-processing facilitated direct analysis and analysis for reproducibility considerably. No differences were found for different commercially available microscopic glass slides regarding suitability of IHC brain researches, but a certain rate of tissue loss should be expected during the staining process.

  4. Validation of a fully automated HER2 staining kit in breast cancer.

    PubMed

    Moelans, Cathy B; Kibbelaar, Robby E; van den Heuvel, Marius C; Castigliego, Domenico; de Weger, Roel A; van Diest, Paul J

    2010-01-01

    Testing for HER2 amplification and/or overexpression is currently routine practice to guide Herceptin therapy in invasive breast cancer. At present, HER2 status is most commonly assessed by immunohistochemistry (IHC). Standardization of HER2 IHC assays is of utmost clinical and economical importance. At present, HER2 IHC is most commonly performed with the HercepTest which contains a polyclonal antibody and applies a manual staining procedure. Analytical variability in HER2 IHC testing could be diminished by a fully automatic staining system with a monoclonal antibody. 219 invasive breast cancers were fully automatically stained with the monoclonal antibody-based Oracle HER2 Bond IHC kit and manually with the HercepTest. All cases were tested for amplification with chromogenic in situ hybridization (CISH). HercepTest yielded an overall sharper membrane staining, with less cytoplasmic and stromal background than Oracle in 17% of cases. Overall concordance between both IHC techniques was 89% (195/219) with a kappa value of 0.776 (95% CI 0.698-0.854), indicating a substantial agreement. Most (22/24) discrepancies between HercepTest and Oracle showed a weaker staining for Oracle. Thirteen of the 24 discrepant cases were high-level HER2 amplified by CISH, and in 12 of these HercepTest IHC better reflected gene amplification status. All the 13 HER2 amplified discrepant cases were at least 2+ by HercepTest, while 10/13 of these were at least 2+ for Oracle. Considering CISH as gold standard, sensitivity of HercepTest and Oracle was 91% and 83%, and specificity was 94% and 98%, respectively. Positive and negative predictive values for HercepTest and Oracle were 90% and 95% for HercepTest and 96% and 91% for Oracle, respectively. Fully-automated HER2 staining with the monoclonal antibody in the Oracle kit shows a high level of agreement with manual staining by the polyclonal antibody in the HercepTest. Although Oracle shows in general some more cytoplasmic staining and may

  5. Histopathological findings in immunohistological staining of the granulomatous tissue reaction associated with tuberculosis.

    PubMed

    Karimi, Shirin; Shamaei, Masoud; Pourabdollah, Mihan; Sadr, Makan; Karbasi, Mehrdad; Kiani, Arda; Bahadori, Moslem

    2014-01-01

    Purpose. The histological diagnosis of Mycobacterium tuberculosis (MTB) remains a diagnostic challenge despite different methods. Immunohistochemistry (IHC) not only could confirm granulomatous tissue involvement but also can demonstrate MTB antigen immunolocalization. This study tries to clarify the details of immunohistochemical staining for MTB with pAbBCG. Materials/Methods. Twenty-three confirmed TB granulomatous tissue samples were studied by Ziehl-Neelsen and immunohistochemistry (IHC) staining with pAbBCG. Samples were selected from the archive of the Department of Pathology, National Research Institute of Tuberculosis and Lung Disease, Tehran, Iran. Results. IHC staining was positive in all samples, whereas Ziehl-Neelsen was positive in 9 cases out of 23 (39.1%). Tissue types used were pleural tissue, lymph nodes, and lung tissue. IHC showed positive coarse granular cytoplasmic and round, fragmented bacillary staining. In this study, epithelioid cells clearly showed more positive staining at the periphery of the granuloma rather than the center of granuloma. There is also positive staining in endothelial cells, fibroblasts, plasma cells, lymphocytes, and macrophages outside the granuloma. Conclusion. Considering the criteria of positive immunohistochemical staining of TB granulomatous reactions, this stain not only highlights the presence of mycobacterial antigens for tissue diagnosis, but also could morphologically localize its distribution in different cells.

  6. Histopathological Findings in Immunohistological Staining of the Granulomatous Tissue Reaction Associated with Tuberculosis

    PubMed Central

    Karimi, Shirin; Pourabdollah, Mihan; Sadr, Makan; Karbasi, Mehrdad; Bahadori, Moslem

    2014-01-01

    Purpose. The histological diagnosis of Mycobacterium tuberculosis (MTB) remains a diagnostic challenge despite different methods. Immunohistochemistry (IHC) not only could confirm granulomatous tissue involvement but also can demonstrate MTB antigen immunolocalization. This study tries to clarify the details of immunohistochemical staining for MTB with pAbBCG. Materials/Methods. Twenty-three confirmed TB granulomatous tissue samples were studied by Ziehl-Neelsen and immunohistochemistry (IHC) staining with pAbBCG. Samples were selected from the archive of the Department of Pathology, National Research Institute of Tuberculosis and Lung Disease, Tehran, Iran. Results. IHC staining was positive in all samples, whereas Ziehl-Neelsen was positive in 9 cases out of 23 (39.1%). Tissue types used were pleural tissue, lymph nodes, and lung tissue. IHC showed positive coarse granular cytoplasmic and round, fragmented bacillary staining. In this study, epithelioid cells clearly showed more positive staining at the periphery of the granuloma rather than the center of granuloma. There is also positive staining in endothelial cells, fibroblasts, plasma cells, lymphocytes, and macrophages outside the granuloma. Conclusion. Considering the criteria of positive immunohistochemical staining of TB granulomatous reactions, this stain not only highlights the presence of mycobacterial antigens for tissue diagnosis, but also could morphologically localize its distribution in different cells. PMID:24511393

  7. Comparing four different ALK antibodies with manual immunohistochemistry (IHC) to screen for ALK-rearranged non-small cell lung cancer (NSCLC).

    PubMed

    Shen, Qin; Wang, Xuan; Yu, Bo; Shi, Shanshan; Liu, Biao; Wang, Yanfen; Xia, Qiuyuan; Rao, Qiu; Zhou, Xiaojun

    2015-12-01

    Anaplastic lymphoma kinase (ALK)-rearranged non-small cell lung cancer (NSCLC) screening is essential to its treatment such as crizotinib. Different assays have been developed to detect ALK rearrangements, such as fluorescence in situ hybridization (FISH), reverse transcriptase-PCR (RT-PCR), and immunohistochemistry (IHC). However, ALK detection has not been applied widely in all hospitals. Moreover, IHC has been proposed to be a pre-screening tool because of its wide application in clinics. Since the low expression of ALK protein, the sensitivity and specificity of ALK antibody are the keys to the success of IHC screening. Therefore, we compared different antibodies to find the best one for IHC detection. We evaluated ALK expression by four different ALK antibodies: clone D5F3 (Ventana), clone D5F3 (CST), clone 1A4/1H7 (OriGene Tech.), and clone 5A4 (Abcam) based on manual IHC in a cohort of 60 NSCLCs. The results were compared with those from automated IHC (clone D5F3, Ventana). All cases were evaluated independently by ALK FISH. 32 ALK-positive and 28 ALK-negative NSCLCs were identified by automated IHC (D5F3, Ventana) and FISH analysis. Based on conventional manual IHC, the sensitivity of four antibodies-D5F3 (Ventana), D5F3 (CST), 1A4/1H7 (OriGene Tech.), and 5A4 (Abcam)-was 93.8%, 84.4%, 93.8%, and 56.3%, respectively. Their specificities and positive predictive values were 100%. The percentage of strong-moderate staining was 65.6%, 62.5%, 68.8%, and 21.9%, respectively. Compared with automated IHC (D5F3, Ventana), each staining concordance was 96.7%, 91.7%, 96.7%, and 76.7%, respectively, and each presented staining heterogeneity (weak-moderate-strong intensity). These data indicated that manual IHC with a more reliable ALK antibody might provide an effective strategy for screening ALK gene rearrangements in all NSCLC patients, followed by confirmatory FISH analysis in IHC-positive cases. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  8. Automated wholeslide analysis of multiplex-brightfield IHC images for cancer cells and carcinoma-associated fibroblasts

    NASA Astrophysics Data System (ADS)

    Lorsakul, Auranuch; Andersson, Emilia; Vega Harring, Suzana; Sade, Hadassah; Grimm, Oliver; Bredno, Joerg

    2017-03-01

    Multiplex-brightfield immunohistochemistry (IHC) staining and quantitative measurement of multiple biomarkers can support therapeutic targeting of carcinoma-associated fibroblasts (CAF). This paper presents an automated digitalpathology solution to simultaneously analyze multiple biomarker expressions within a single tissue section stained with an IHC duplex assay. Our method was verified against ground truth provided by expert pathologists. In the first stage, the automated method quantified epithelial-carcinoma cells expressing cytokeratin (CK) using robust nucleus detection and supervised cell-by-cell classification algorithms with a combination of nucleus and contextual features. Using fibroblast activation protein (FAP) as biomarker for CAFs, the algorithm was trained, based on ground truth obtained from pathologists, to automatically identify tumor-associated stroma using a supervised-generation rule. The algorithm reported distance to nearest neighbor in the populations of tumor cells and activated-stromal fibroblasts as a wholeslide measure of spatial relationships. A total of 45 slides from six indications (breast, pancreatic, colorectal, lung, ovarian, and head-and-neck cancers) were included for training and verification. CK-positive cells detected by the algorithm were verified by a pathologist with good agreement (R2=0.98) to ground-truth count. For the area occupied by FAP-positive cells, the inter-observer agreement between two sets of ground-truth measurements was R2=0.93 whereas the algorithm reproduced the pathologists' areas with R2=0.96. The proposed methodology enables automated image analysis to measure spatial relationships of cells stained in an IHC-multiplex assay. Our proof-of-concept results show an automated algorithm can be trained to reproduce the expert assessment and provide quantitative readouts that potentially support a cutoff determination in hypothesis testing related to CAF-targeting-therapy decisions.

  9. Image processing in digital pathology: an opportunity to solve inter-batch variability of immunohistochemical staining

    NASA Astrophysics Data System (ADS)

    van Eycke, Yves-Rémi; Allard, Justine; Salmon, Isabelle; Debeir, Olivier; Decaestecker, Christine

    2017-02-01

    Immunohistochemistry (IHC) is a widely used technique in pathology to evidence protein expression in tissue samples. However, this staining technique is known for presenting inter-batch variations. Whole slide imaging in digital pathology offers a possibility to overcome this problem by means of image normalisation techniques. In the present paper we propose a methodology to objectively evaluate the need of image normalisation and to identify the best way to perform it. This methodology uses tissue microarray (TMA) materials and statistical analyses to evidence the possible variations occurring at colour and intensity levels as well as to evaluate the efficiency of image normalisation methods in correcting them. We applied our methodology to test different methods of image normalisation based on blind colour deconvolution that we adapted for IHC staining. These tests were carried out for different IHC experiments on different tissue types and targeting different proteins with different subcellular localisations. Our methodology enabled us to establish and to validate inter-batch normalization transforms which correct the non-relevant IHC staining variations. The normalised image series were then processed to extract coherent quantitative features characterising the IHC staining patterns.

  10. Image processing in digital pathology: an opportunity to solve inter-batch variability of immunohistochemical staining

    PubMed Central

    Van Eycke, Yves-Rémi; Allard, Justine; Salmon, Isabelle; Debeir, Olivier; Decaestecker, Christine

    2017-01-01

    Immunohistochemistry (IHC) is a widely used technique in pathology to evidence protein expression in tissue samples. However, this staining technique is known for presenting inter-batch variations. Whole slide imaging in digital pathology offers a possibility to overcome this problem by means of image normalisation techniques. In the present paper we propose a methodology to objectively evaluate the need of image normalisation and to identify the best way to perform it. This methodology uses tissue microarray (TMA) materials and statistical analyses to evidence the possible variations occurring at colour and intensity levels as well as to evaluate the efficiency of image normalisation methods in correcting them. We applied our methodology to test different methods of image normalisation based on blind colour deconvolution that we adapted for IHC staining. These tests were carried out for different IHC experiments on different tissue types and targeting different proteins with different subcellular localisations. Our methodology enabled us to establish and to validate inter-batch normalization transforms which correct the non-relevant IHC staining variations. The normalised image series were then processed to extract coherent quantitative features characterising the IHC staining patterns. PMID:28220842

  11. Sensitivity of Helicobacter pylori detection by Giemsa staining is poor in comparison with immunohistochemistry and fluorescent in situ hybridization and strongly depends on inflammatory activity.

    PubMed

    Kocsmár, Éva; Szirtes, Ildikó; Kramer, Zsófia; Szijártó, Attila; Bene, László; Buzás, György Miklós; Kenessey, István; Bronsert, Peter; Csanadi, Agnes; Lutz, Lisa; Werner, Martin; Wellner, Ulrich Friedrich; Kiss, András; Schaff, Zsuzsa; Lotz, Gábor

    2017-08-01

    Conventional stainings (including H&E and special stains like Giemsa) are the most widely applied histopathologic detection methods of Helicobacter pylori (HP). We aimed to compare the diagnostic performance of Giemsa staining with immunohistochemistry (IHC) and fluorescent in situ hybridization (FISH) on a monocentric cohort of 2896 gastric biopsies and relate results to histologic alterations in order to find such histopathologic subgroups in which these methods underperform. All cases were categorized regarding presence or absence of chronic gastritis, inflammatory activity, and mucosal structural alterations. Giemsa revealed 687 cases (23.7%), IHC 795 cases (27.5%), and FISH 788 cases (27.2%) as being HP positive. Giemsa showed significantly lower overall sensitivity (83.3%) compared to IHC (98.8%) and FISH (98.0%). Moreover, the sensitivity of Giemsa dramatically dropped to 33.6% in the nonactive cases. We found that sensitivity of Giemsa strongly depends on HP density and, accordingly, on the presence of activity. Structural alterations (intestinal metaplasia, atrophy, etc.) had only no or weak effect on sensitivity of the three stainings. Both IHC and FISH proved to be equally reliable HP detecting techniques whose diagnostic performance is minimally influenced by mucosal inflammatory and structural alterations contrary to conventional stainings. We highly recommend immunohistochemistry for clinically susceptible, nonactive chronic gastritis cases, if the conventional stain-based HP detection is negative. Moreover, we recommend to use IHC more widely as basic HP stain. Helicobacter pylori FISH technique is primarily recommended to determine bacterial clarithromycin resistance. Furthermore, it is another accurate diagnostic tool for HP. © 2017 John Wiley & Sons Ltd.

  12. Digital immunohistochemistry platform for the staining variation monitoring based on integration of image and statistical analyses with laboratory information system.

    PubMed

    Laurinaviciene, Aida; Plancoulaine, Benoit; Baltrusaityte, Indra; Meskauskas, Raimundas; Besusparis, Justinas; Lesciute-Krilaviciene, Daiva; Raudeliunas, Darius; Iqbal, Yasir; Herlin, Paulette; Laurinavicius, Arvydas

    2014-01-01

    Digital immunohistochemistry (IHC) is one of the most promising applications brought by new generation image analysis (IA). While conventional IHC staining quality is monitored by semi-quantitative visual evaluation of tissue controls, IA may require more sensitive measurement. We designed an automated system to digitally monitor IHC multi-tissue controls, based on SQL-level integration of laboratory information system with image and statistical analysis tools. Consecutive sections of TMA containing 10 cores of breast cancer tissue were used as tissue controls in routine Ki67 IHC testing. Ventana slide label barcode ID was sent to the LIS to register the serial section sequence. The slides were stained and scanned (Aperio ScanScope XT), IA was performed by the Aperio/Leica Colocalization and Genie Classifier/Nuclear algorithms. SQL-based integration ensured automated statistical analysis of the IA data by the SAS Enterprise Guide project. Factor analysis and plot visualizations were performed to explore slide-to-slide variation of the Ki67 IHC staining results in the control tissue. Slide-to-slide intra-core IHC staining analysis revealed rather significant variation of the variables reflecting the sample size, while Brown and Blue Intensity were relatively stable. To further investigate this variation, the IA results from the 10 cores were aggregated to minimize tissue-related variance. Factor analysis revealed association between the variables reflecting the sample size detected by IA and Blue Intensity. Since the main feature to be extracted from the tissue controls was staining intensity, we further explored the variation of the intensity variables in the individual cores. MeanBrownBlue Intensity ((Brown+Blue)/2) and DiffBrownBlue Intensity (Brown-Blue) were introduced to better contrast the absolute intensity and the colour balance variation in each core; relevant factor scores were extracted. Finally, tissue-related factors of IHC staining variance were

  13. Digital immunohistochemistry platform for the staining variation monitoring based on integration of image and statistical analyses with laboratory information system

    PubMed Central

    2014-01-01

    Background Digital immunohistochemistry (IHC) is one of the most promising applications brought by new generation image analysis (IA). While conventional IHC staining quality is monitored by semi-quantitative visual evaluation of tissue controls, IA may require more sensitive measurement. We designed an automated system to digitally monitor IHC multi-tissue controls, based on SQL-level integration of laboratory information system with image and statistical analysis tools. Methods Consecutive sections of TMA containing 10 cores of breast cancer tissue were used as tissue controls in routine Ki67 IHC testing. Ventana slide label barcode ID was sent to the LIS to register the serial section sequence. The slides were stained and scanned (Aperio ScanScope XT), IA was performed by the Aperio/Leica Colocalization and Genie Classifier/Nuclear algorithms. SQL-based integration ensured automated statistical analysis of the IA data by the SAS Enterprise Guide project. Factor analysis and plot visualizations were performed to explore slide-to-slide variation of the Ki67 IHC staining results in the control tissue. Results Slide-to-slide intra-core IHC staining analysis revealed rather significant variation of the variables reflecting the sample size, while Brown and Blue Intensity were relatively stable. To further investigate this variation, the IA results from the 10 cores were aggregated to minimize tissue-related variance. Factor analysis revealed association between the variables reflecting the sample size detected by IA and Blue Intensity. Since the main feature to be extracted from the tissue controls was staining intensity, we further explored the variation of the intensity variables in the individual cores. MeanBrownBlue Intensity ((Brown+Blue)/2) and DiffBrownBlue Intensity (Brown-Blue) were introduced to better contrast the absolute intensity and the colour balance variation in each core; relevant factor scores were extracted. Finally, tissue-related factors of IHC

  14. New MYC IHC Classifier Integrating Quantitative Architecture Parameters to Predict MYC Gene Translocation in Diffuse Large B-Cell Lymphoma

    PubMed Central

    Dong, Wei-Feng; Canil, Sarah; Lai, Raymond; Morel, Didier; Swanson, Paul E.; Izevbaye, Iyare

    2018-01-01

    A new automated MYC IHC classifier based on bivariate logistic regression is presented. The predictor relies on image analysis developed with the open-source ImageJ platform. From a histologic section immunostained for MYC protein, 2 dimensionless quantitative variables are extracted: (a) relative distance between nuclei positive for MYC IHC based on euclidean minimum spanning tree graph and (b) coefficient of variation of the MYC IHC stain intensity among MYC IHC-positive nuclei. Distance between positive nuclei is suggested to inversely correlate MYC gene rearrangement status, whereas coefficient of variation is suggested to inversely correlate physiological regulation of MYC protein expression. The bivariate classifier was compared with 2 other MYC IHC classifiers (based on percentage of MYC IHC positive nuclei), all tested on 113 lymphomas including mostly diffuse large B-cell lymphomas with known MYC fluorescent in situ hybridization (FISH) status. The bivariate classifier strongly outperformed the “percentage of MYC IHC-positive nuclei” methods to predict MYC+ FISH status with 100% sensitivity (95% confidence interval, 94-100) associated with 80% specificity. The test is rapidly performed and might at a minimum provide primary IHC screening for MYC gene rearrangement status in diffuse large B-cell lymphomas. Furthermore, as this bivariate classifier actually predicts “permanent overexpressed MYC protein status,” it might identify nontranslocation-related chromosomal anomalies missed by FISH. PMID:27093450

  15. Microfluidics for rapid cytokeratin immunohistochemical staining in frozen sections.

    PubMed

    Brajkovic, Saska; Dupouy, Diego G; de Leval, Laurence; Gijs, Martin Am

    2017-08-01

    Frozen sections (FS) of tumor samples represent a cornerstone of pathological intraoperative consultation and have an important role in the microscopic analysis of specimens during surgery. So far, immunohistochemical (IHC) stainings on FS have been demonstrated for a few markers using manual methods. Microfluidic technologies have proven to bring substantial improvement in many fields of diagnostics, though only a few microfluidic devices have been designed to improve the performance of IHC assays. In this work, we show optimization of a complete pan-cytokeratin chromogenic immunostaining protocol on FS using a microfluidic tissue processor into a protocol taking <12 min. Our results showed specificity and low levels of background. The dimensions of the microfluidic prototype device are compatible with the space constraints of an intraoperative pathology laboratory. We therefore anticipate that the adoption of microfluidic technologies in the field of surgical pathology can significantly improve the way FSs influence surgical procedures.

  16. Microfluidics for rapid cytokeratin immunohistochemical staining in frozen sections

    PubMed Central

    Brajkovic, Saska; Dupouy, Diego G.; de Leval, Laurence; Gijs, Martin A. M.

    2017-01-01

    Frozen sections (FS) of tumor samples represent a cornerstone of pathological intraoperative consultation and play an important role in the microscopic analysis of specimens during surgery. So far, immunohistochemical (IHC) stainings on FS have been demonstrated for a few markers using manual methods. Microfluidic technologies have proven to bring substantial improvement in many fields of diagnostics, though only a few microfluidic devices have been designed to improve the performance of IHC assays. In this work, we show optimization of a complete pan-cytokeratin chromogenic immunostaining protocol on FS using a microfluidic tissue processor, into a protocol taking less than 12 minutes. Our results showed specificity and low levels of background. The dimensions of the microfluidic prototype device are compatible with the space constraints of an intraoperative pathology laboratory. We therefore anticipate that the adoption of microfluidic technologies in the field of surgical pathology can significantly improve the way FSs influence surgical procedures. PMID:28553936

  17. IHC-TM connect-disconnect and efferent control V.

    PubMed

    Crane, H D

    1982-07-01

    Four previous papers in this series have explored how the idea of a set of disconnected inner hair cells (IHCs) that can "impact" the tectorial membrane (TM) is consistent with psychophysical data. This paper extends the model and explores the potential for mechanical interaction between the IHCs and outer hair cells (OHCs). In particular, it is speculated that the advantage of IHC-TM disconnect is extended dynamic range, and that movement of the movement of the OHCs and TM, under efferent control, constitutes a mechanical servo system for adjusting IHC-TM spacing along the cochlear partition to achieve this extended range.

  18. VEGF: A critical driver for angiogenesis and subsequent tumor growth: An IHC study

    PubMed Central

    Kapoor, Prakhar; Deshmukh, RS

    2012-01-01

    Background: Tumors require blood supply for their growth and dissemination. It is a well accepted paradigm that tumors recruit new blood vessels from the existing circulation (angiogenesis) and this participates in tumor invasion and metastasis. Studies in the literature provide evidence for expression of Vascular Endothelial Growth Factor (VEGF) by the tumor for neo-angiogenesis, which is not only required for the tumor growth but also its metastasis. Based on the literary evidences we carried out an Immuno-Histochemical (IHC) study for VEGF in Oral Squamous Cell Carcinoma (OSCC) tissues to provide a strong link between the factor and oral cancer. Aim: To analyze the expression of VEGF in OSCC tissues of different histological grades, clinical sizes and lymph node status and to use this as an indicator for disease progression by helping in delineating a risk population, that may benefit from an attractive adjuvant therapeutic strategy for OSCC. Settings and Design: Studies published from 1990 till 2010 have only seen the association of VEGF with tumor angiogenesis and its possible role in metastasis. This is the first study that takes into account the clinical status of the lymph nodes and VEGF expressivity in a sample size of 30 cases. Materials and Methods: 30 oral squamous cell carcinoma tissue slides were stained using Hematoxylin and Eosin stain (to confirm the diagnosis) and immunohistochemically using VEGF antibody. IHC stained slides were thereafter evaluated for the positivity and intensity. Statistical Analysis: The result was subjected to statistical analysis using Chi-square test Results and Conclusion: VEGF positivity was seen in approximately. 90% of cases which was independent of histological grade of OSCC. However the intensity increased with the clinical size of cancer and from palpable lymph node to a tender and hard lymph node. PMID:23248460

  19. Does immunohistochemical staining have a clinical impact in early gastric cancer conducted endoscopic submucosal dissection?

    PubMed Central

    Jeon, Seong Ran; Cho, Joo Young; Bok, Gene Hyun; Lee, Tae Hee; Kim, Hyun Gun; Cho, Won Young; Jin, So Young; Kim, Yeon Soo

    2012-01-01

    AIM: To evaluate clinicopathologic parameters and the clinical significance related lymphovascular invasion (LVI) by immunohistochemical staining (IHCS) in endoscopic submucosal dissection (ESD). METHODS: Between May 2005 and May 2010, a total of 348 lesions from 321 patients (mean age 63 ± 10 years, men 74.6%) with early gastric cancer (EGC) who met indication criteria after ESD were analyzed retrospectively. The 348 lesions were divided into the absolute (n = 100, differentiated mucosal cancer without ulcer ≤ 20 mm) and expanded (n = 248) indication groups after ESD. The 248 lesions were divided into four subgroups according to the expanded ESD indication. The presence of LVI was determined by factor VIII-related antigen and D2-40 assessment. We compared LVI IHCS-negative group with LVI IHCS-positive in each group. RESULTS: LVI by hematoxylin-eosin staining (HES) and IHCS were all negative in the absolute group, while was observed in only the expanded groups. The positive rate of LVI by IHCS was higher than that of LVI by HES (n = 1, 0.4% vs n = 11, 4.4%, P = 0.044). LVI IHCS-positivity was observed when the cancer invaded to the mucosa 3 (M3) or submucosa 1 (SM1) levels, with a predominance of 63.6% in the subgroup that included only SM1 cancer (P < 0.01). In a univariate analysis, M3 or SM1 invasion by the tumor was significantly associated with a higher rate of LVI by IHCS, but no factor was significant in a multivariate analysis. There were no cases of tumor recurrence or metastasis during the median 26 mo follow-up. CONCLUSION: EGCs of the absolute group are immunohistochemically stable. The presence of LVI may be carefully examined by IHCS in an ESD expanded indication group with an invasion depth of M3 or greater. PMID:22969232

  20. Evolution of Quality Assurance for Clinical Immunohistochemistry in the Era of Precision Medicine. Part 3: Technical Validation of Immunohistochemistry (IHC) Assays in Clinical IHC Laboratories.

    PubMed

    Torlakovic, Emina E; Cheung, Carol C; D'Arrigo, Corrado; Dietel, Manfred; Francis, Glenn D; Gilks, C Blake; Hall, Jacqueline A; Hornick, Jason L; Ibrahim, Merdol; Marchetti, Antonio; Miller, Keith; van Krieken, J Han; Nielsen, Soren; Swanson, Paul E; Vyberg, Mogens; Zhou, Xiaoge; Taylor, Clive R

    2017-03-01

    Validation of immunohistochemistry (IHC) assays is a subject that is of great importance to clinical practice as well as basic research and clinical trials. When applied to clinical practice and focused on patient safety, validation of IHC assays creates objective evidence that IHC assays used for patient care are "fit-for-purpose." Validation of IHC assays needs to be properly informed by and modeled to assess the purpose of the IHC assay, which will further determine what sphere of validation is required, as well as the scope, type, and tier of technical validation. These concepts will be defined in this review, part 3 of the 4-part series "Evolution of Quality Assurance for Clinical Immunohistochemistry in the Era of Precision Medicine."

  1. High anaplastic lymphoma kinase immunohistochemical staining in neuroblastoma and ganglioneuroblastoma is an independent predictor of poor outcome.

    PubMed

    Duijkers, Floor A M; Gaal, José; Meijerink, Jules P P; Admiraal, Pieter; Pieters, Rob; de Krijger, Ronald R; van Noesel, Max M

    2012-03-01

    Anaplastic lymphoma kinase (ALK) mutations occur in 3% to 11% of neuroblastoma (NBL) cases and are associated with high ALK levels. However, high ALK levels appear to be a mutation-independent hallmark of NBL. Evidence about the prognostic relevance of ALK mutations and ALK tumor positivity in patients with NBL has been inconclusive. In this study, we investigated the prognostic relevance of ALK positivity by IHC and ALK mutation status by PCR sequencing in 71 NBL, 12 ganglioneuroblastoma (GNBL), and 20 ganglioneuroma samples in a multivariate model. ALK mutations were present in 2 of 72 NBL and 2 of 12 GNBL samples, which all contained many ALK-positive cells (>50%). In addition, half of all NBL samples showed ALK positivity in most (>50%) of tumor cells, whereas half of the GNBL showed staining in <20% of the tumor cells. In most ganglioneuroma samples, a low percentage of tumor cells stained positive for ALK, which mainly involved ganglion cells. Higher percentages of ALK-positive cells in NBL and GNBL patient samples correlated with inferior survival in univariate and multivariate analyses with established prognostic factors, such as stage, age, and MYCN status. In conclusion, ALK positivity by IHC is an independent, poor prognostic factor in patients with GNBL and NBL. ALK IHC is an easy test suitable for future risk stratification in patients with NBL and GNBL. Copyright © 2012 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.

  2. Cellient™ automated cell block versus traditional cell block preparation: a comparison of morphologic features and immunohistochemical staining.

    PubMed

    Wagner, David G; Russell, Donna K; Benson, Jenna M; Schneider, Ashley E; Hoda, Rana S; Bonfiglio, Thomas A

    2011-10-01

    Traditional cell block (TCB) sections serve as an important diagnostic adjunct to cytologic smears but are also used today as a reliable preparation for immunohistochemical (IHC) studies. There are many ways to prepare a cell block and the methods continue to be revised. In this study, we compare the TCB with the Cellient™ automated cell block system. Thirty-five cell blocks were obtained from 16 benign and 19 malignant nongynecologic cytology specimens at a large university teaching hospital and prepared according to TCB and Cellient protocols. Cell block sections from both methods were compared for possible differences in various morphologic features and immunohistochemical staining patterns. In the 16 benign cases, no significant morphologic differences were found between the TCB and Cellient cell block sections. For the 19 malignant cases, some noticeable differences in the nuclear chromatin and cellularity were identified, although statistical significance was not attained. Immunohistochemical or special stains were performed on 89% of the malignant cases (17/19). Inadequate cellularity precluded full evaluation in 23% of Cellient cell block IHC preparations (4/17). Of the malignant cases with adequate cellularity (13/17), the immunohistochemical staining patterns from the different methods were identical in 53% of cases. The traditional and Cellient cell block sections showed similar morphologic and immunohistochemical staining patterns. The only significant difference between the two methods concerned the lower overall cell block cellularity identified during immunohistochemical staining in the Cellient cell block sections. Copyright © 2010 Wiley-Liss, Inc.

  3. Modified rapid immunohistochemical staining for intraoperative diagnosis of malignant brain tumors.

    PubMed

    Suzuki, Akane; Maruyama, Takashi; Nitta, Masayuki; Komori, Takashi; Ikuta, Soko; Kawamata, Takakazu; Muragaki, Yoshihiro

    2017-10-01

    Rapid immunohistochemistry (R-IHC) has been developing mainly as a support technique in the rapid diagnosis of central nervous system tumors; however, there have been problems regarding instability in specimen preparation and immunostaining. To overcome the weakness of this technology, the instability of immunostaining, we developed a modified R-IHC. This was achieved by switching to 4% paraformaldehyde as the fixative solution and utilizing a commercially available Polymer Refine Detection Kit, as a high-sensitivity kit, in place of the secondary antibodies. In this study, we tested the modified R-IHC by evaluating rapid immunostaining on new staining items in 94 brain tumor removal cases, which took place at Tokyo Women's Medical University from 2014 to 2015. The results showed that, based on GFAP and p53 markers, the modified method obtained a higher stability in specimens than the standard rapid immunostaining method. It also achieved stainability on the same level as that of a permanent specimen. The modified method tested 86.6% (46/53) and 82.8% (24/29) in pHH3 and ATRX, respectively, in the percentage of correct classification (PCC) against the permanent specimens, and 100% (7/7) in the PCC against malignant lymphomas and gliomas that used CD20/CD3 for discrimination. We concluded that the modified R-IHC method indicated a higher stainability and PCC against the permanent specimens in comparison to the standard method in GFAP, p53, CD20/CD3, pHH3, and ATRX.

  4. Segmentation of HER2 protein overexpression in immunohistochemically stained breast cancer images using Support Vector Machines

    NASA Astrophysics Data System (ADS)

    Pezoa, Raquel; Salinas, Luis; Torres, Claudio; Härtel, Steffen; Maureira-Fredes, Cristián; Arce, Paola

    2016-10-01

    Breast cancer is one of the most common cancers in women worldwide. Patient therapy is widely supported by analysis of immunohistochemically (IHC) stained tissue sections. In particular, the analysis of HER2 overexpression by immunohistochemistry helps to determine when patients are suitable to HER2-targeted treatment. Computational HER2 overexpression analysis is still an open problem and a challenging task principally because of the variability of immunohistochemistry tissue samples and the subjectivity of the specialists to assess the samples. In addition, the immunohistochemistry process can produce diverse artifacts that difficult the HER2 overexpression assessment. In this paper we study the segmentation of HER2 overexpression in IHC stained breast cancer tissue images using a support vector machine (SVM) classifier. We asses the SVM performance using diverse color and texture pixel-level features including the RGB, CMYK, HSV, CIE L*a*b* color spaces, color deconvolution filter and Haralick features. We measure classification performance for three datasets containing a total of 153 IHC images that were previously labeled by a pathologist.

  5. An immunohistochemical and fluorescence in situ hybridization-based comparison between the Oracle HER2 Bond Immunohistochemical System, Dako HercepTest, and Vysis PathVysion HER2 FISH using both commercially validated and modified ASCO/CAP and United Kingdom HER2 IHC scoring guidelines.

    PubMed

    O'Grady, Anthony; Allen, David; Happerfield, Lisa; Johnson, Nicola; Provenzano, Elena; Pinder, Sarah E; Tee, Lilian; Gu, Mai; Kay, Elaine W

    2010-12-01

    Immunohistochemistry (IHC) is used as the frontline assay to determine HER2 status in invasive breast cancer patients. The aim of the study was to compare the performance of the Leica Oracle HER2 Bond IHC System (Oracle) with the current most readily accepted Dako HercepTest (HercepTest), using both commercially validated and modified ASCO/CAP and UK HER2 IHC scoring guidelines. A total of 445 breast cancer samples from 3 international clinical HER2 referral centers were stained with the 2 test systems and scored in a blinded fashion by experienced pathologists. The overall agreement between the 2 tests in a 3×3 (negative, equivocal and positive) analysis shows a concordance of 86.7% and 86.3%, respectively when analyzed using commercially validated and modified ASCO/CAP and UK HER2 IHC scoring guidelines. There is a good concordance between the Oracle and the HercepTest. The advantages of a complete fully automated test such as the Oracle include standardization of key analytical factors and improved turn around time. The implementation of the modified ASCO/CAP and UK HER2 IHC scoring guidelines has minimal effect on either assay interpretation, showing that Oracle can be used as a methodology for accurately determining HER2 IHC status in formalin fixed, paraffin-embedded breast cancer tissue.

  6. Epitope-positive truncating MLH1 mutation and loss of PMS2: implications for IHC-directed genetic testing for Lynch syndrome.

    PubMed

    Zighelboim, Israel; Powell, Matthew A; Babb, Sheri A; Whelan, Alison J; Schmidt, Amy P; Clendenning, Mark; Senter, Leigha; Thibodeau, Stephen N; de la Chapelle, Albert; Goodfellow, Paul J

    2009-01-01

    We assessed mismatch repair by immunohistochemistry (IHC) and microsatellite instability (MSI) analysis in an early onset endometrial cancer and a sister's colon cancer. We demonstrated high-level MSI and normal expression for MLH1, MSH2 and MSH6. PMS2 failed to stain in both tumors, strongly implicating a PMS2 defect. This family did not meet clinical criteria for Lynch syndrome. However, early onset endometrial cancers in the proband and her sister, a metachronous colorectal cancer in the sister as well as MSI in endometrial and colonic tumors suggested a heritable mismatch repair defect. PCR-based direct exonic sequencing and multiplex ligation-dependent probe amplification (MLPA) were undertaken to search for PMS2 mutations in the germline DNA from the proband and her sister. No mutation was identified in the PMS2 gene. However, PMS2 exons 3, 4, 13, 14, 15 were not evaluated by MLPA and as such, rearrangements involving those exons cannot be excluded. Clinical testing for MLH1 and MSH2 mutation revealed a germline deletion of MLH1 exons 14 and 15. This MLH1 germline deletion leads to an immunodetectable stable C-terminal truncated MLH1 protein which based on the IHC staining must abrogate PMS2 stabilization. To the best of our knowledge, loss of PMS2 in MLH1 truncating mutation carriers that express MLH1 in their tumors has not been previously reported. This family points to a potential limitation of IHC-directed gene testing for suspected Lynch syndrome and the need to consider comprehensive MLH1 testing for individuals whose tumors lack PMS2 but for whom PMS2 mutations are not identified.

  7. Digital simulation of staining in histopathology multispectral images: enhancement and linear transformation of spectral transmittance.

    PubMed

    Bautista, Pinky A; Yagi, Yukako

    2012-05-01

    Hematoxylin and eosin (H&E) stain is currently the most popular for routine histopathology staining. Special and/or immuno-histochemical (IHC) staining is often requested to further corroborate the initial diagnosis on H&E stained tissue sections. Digital simulation of staining (or digital staining) can be a very valuable tool to produce the desired stained images from the H&E stained tissue sections instantaneously. We present an approach to digital staining of histopathology multispectral images by combining the effects of spectral enhancement and spectral transformation. Spectral enhancement is accomplished by shifting the N-band original spectrum of the multispectral pixel with the weighted difference between the pixel's original and estimated spectrum; the spectrum is estimated using M < N principal component (PC) vectors. The pixel's enhanced spectrum is transformed to the spectral configuration associated to its reaction to a specific stain by utilizing an N × N transformation matrix, which is derived through application of least mean squares method to the enhanced and target spectral transmittance samples of the different tissue components found in the image. Results of our experiments on the digital conversion of an H&E stained multispectral image to its Masson's trichrome stained equivalent show the viability of the method.

  8. Responses to crizotinib in patients with ALK-positive lung adenocarcinoma who tested immunohistochemistry (IHC)-positive and fluorescence in situ hybridization (FISH)-negative.

    PubMed

    Ma, Di; Wang, Zheng; Yang, Lin; Mu, Xinlin; Wang, Yan; Zhao, Xinming; Li, Junling; Lin, Dongmei

    2016-09-27

    Although the Ventana immunohistochemistry (IHC) platform for detecting anaplastic lymphoma kinase gene (ALK) (D5F3) expression was recently approved by the US Food and Drugs Administration (FDA), fluorescence in situ hybridization (FISH) is still the "gold-standard" method recommended by the US National Comprehensive Cancer Network (NCCN) guideline for NSCLC. We evaluated 6 ALK-positive lung adenocarcinoma patients who tested Ventana IHC-positive and FISH-negative and assessed their clinical responses to the ALK tyrosine kinase inhibitor (TKI) crizotinib. Histologic and cytologic specimens from the 6 patients were stained with Ventana anti-ALK(D5F3) rabbit monoclonal primary antibody using the OptiView™ DAB IHC detection kit and OptiView™ amplification kit on a Ventana BenchMark XT processor. In addition, they were also tested by FISH, qRT-PCR, next-generation sequencing (NGS), and RNAscope ISH analysis. All patients received crizotinib treatment and their follow-up clinical data were recorded. The objective response rate achieved with crizotinib therapy was 66.7% (4/6 partial responses and 2/6 stable disease). One patient in whom a new fusion type (EML4->EXOC6B->ALK fusion) was identified obtained a partial response. These findings indicate that patients with ALK-positive lung adenocarcinoma who test Ventana IHC-positive and FISH-negative may still respond to crizotinib therapy.

  9. Comparison of IHC, FISH and RT-PCR methods for detection of ALK rearrangements in 312 non-small cell lung cancer patients in Taiwan.

    PubMed

    Wu, Yi-Cheng; Chang, Il-Chi; Wang, Chi-Liang; Chen, Tai-Di; Chen, Ya-Ting; Liu, Hui-Ping; Chu, Yen; Chiu, Yu-Ting; Wu, Tzu-Hua; Chou, Li-Hui; Chen, Yi-Rong; Huang, Shiu-Feng

    2013-01-01

    Recently Echinoderm microtubule-associated protein-like 4- anaplastic lymphoma kinase (EML4-ALK) fusion gene has become an important biomarker for ALK tyrosine kinase inhibitor (crizotinib) treatment in NSCLC. However, the best detection method and the significance of EML4-ALK variant types remain uncertain. Reverse transcriptase-polymerase chain reaction (RT-PCR), fluorescence in Situ hybridization (FISH) and Immunohistochemical (IHC) stain were performed on tumor tissues of 312 NSCLC patients for detection of ALK rearrangements. Mutation analyses for EGFR and KRAS genes were also performed. Thirteen of the 312 patients (4.17%) had ALK rearrangements detected by RT-PCR. If RT-PCR data was used as the gold standard, FISH tests had a low sensitivity (58.33%), but very good specificity (99.32%). IHC stain had better sensitivity (91.67%) than FISH, but lower specificity (79.52%), when the cut off was IHC2+. All of the 8 patients with high abundance of EML4-ALK positive cells in tumor tissues (assessed by the signal intensities of the RT-PCR product), were also have high expression of ALK protein (IHC3+), and positive for FISH, except one failed in FISH. Variants 3a+3b (4/5, 80%) of EML4-ALK fusion gene were more common to have high abundance of EML4-ALK positive cells in tumor tissues than variant 1 (1/3, 33.3%). Meta-analysis of the published data of 2273 NSCLC patients revealed that variant 3 (23/44, 52.3%) was the most common type in Chinese population, while variant 1 (28/37, 75.7%) was most common in Caucasian. Among the three detection methods, RT-PCR could detect not only the presence of EML4-ALK fusion gene and their variant types, but also the abundance of EML4-ALK positive cells in NSCLC tumor tissues. The latter two factors might affect the treatment response to anti-ALK inhibitor. Including RT-PCR as a diagnostic test for ALK inhibitor treatment in the prospective clinical trials is recommended.

  10. Comparison of IHC, FISH and RT-PCR Methods for Detection of ALK Rearrangements in 312 Non-Small Cell Lung Cancer Patients in Taiwan

    PubMed Central

    Wang, Chi-Liang; Chen, Tai-Di; Chen, Ya-Ting; Liu, Hui-Ping; Chu, Yen; Chiu, Yu-Ting; Wu, Tzu-Hua; Chou, Li-Hui; Chen, Yi-Rong; Huang, Shiu-Feng

    2013-01-01

    Background Recently Echinoderm microtubule-associated protein-like 4- anaplastic lymphoma kinase (EML4-ALK) fusion gene has become an important biomarker for ALK tyrosine kinase inhibitor (crizotinib) treatment in NSCLC. However, the best detection method and the significance of EML4-ALK variant types remain uncertain. Methods Reverse transcriptase-polymerase chain reaction (RT-PCR), fluorescence in Situ hybridization (FISH) and Immunohistochemical (IHC) stain were performed on tumor tissues of 312 NSCLC patients for detection of ALK rearrangements. Mutation analyses for EGFR and KRAS genes were also performed. Results Thirteen of the 312 patients (4.17%) had ALK rearrangements detected by RT-PCR. If RT-PCR data was used as the gold standard, FISH tests had a low sensitivity (58.33%), but very good specificity (99.32%). IHC stain had better sensitivity (91.67%) than FISH, but lower specificity (79.52%), when the cut off was IHC2+. All of the 8 patients with high abundance of EML4-ALK positive cells in tumor tissues (assessed by the signal intensities of the RT-PCR product), were also have high expression of ALK protein (IHC3+), and positive for FISH, except one failed in FISH. Variants 3a+3b (4/5, 80%) of EML4-ALK fusion gene were more common to have high abundance of EML4-ALK positive cells in tumor tissues than variant 1 (1/3, 33.3%). Meta-analysis of the published data of 2273 NSCLC patients revealed that variant 3 (23/44, 52.3%) was the most common type in Chinese population, while variant 1 (28/37, 75.7%) was most common in Caucasian. Conclusions Among the three detection methods, RT-PCR could detect not only the presence of EML4-ALK fusion gene and their variant types, but also the abundance of EML4-ALK positive cells in NSCLC tumor tissues. The latter two factors might affect the treatment response to anti-ALK inhibitor. Including RT-PCR as a diagnostic test for ALK inhibitor treatment in the prospective clinical trials is recommended. PMID:23951022

  11. Evaluation of HER-2/neu status in breast cancer specimens using immunohistochemistry (IHC) & fluorescence in-situ hybridization (FISH) assay.

    PubMed

    Goud, Kalal Iravathy; Dayakar, Seetha; Vijayalaxmi, Kolanupaka; Babu, Saidam Jangu; Reddy, P Vijay Anand

    2012-03-01

    Fluorescence in situ hybridization (FISH) is increasingly being recognized as the most accurate and predictive test for HER 2/neu gene amplification and response to therapy in breast cancer. In the present study we investigated HER-2/neu gene amplification by FISH in breast carcinoma tissue specimens and compared the results with that of immunohistochemical (IHC) analysis. A total of 90 breast carcinoma tissue samples were used for immunohistochemical (IHC) and FISH analysis. IHC was performed by using mouse monoclonal antibody to the intracellular domain of HER-2/neu protein. Each slide was scored in a blinded fashion by two pathologists according to the manufacturer's recommended criteria. FISH analysis was performed on paraffin embedded breast tumour tissue sections. The polysomy for centromere 17 (Spec green signal) was read as green signals less than 4 as moderate polysomy, and more than 4 as highly polysomy. Thirty of the 90 patients had negative results by IHC and FISH. Of the 28 patients with the score of 2+ by IHC, 20 were FISH positive for HER-2/neu gene amplification, three were FISH negative and five patients showed equivocal (1.8-2.2) results by FISH. These five cases were retested for IHC and FISH on different paraffin embedded tissue blocks, and all five were found positive for HER-2/neu gene amplification. Twenty five patients with the score of 3+ by IHC were FISH positive for HER-2/neu gene amplification (>2.2). Seven cases with the score of 3+ by IHC were FISH negative for HER-2/neu gene amplification (>2.2), and showed polysomy of chromosome number 17 high polysomy > 4. Our results indicated that HER-2/neu status by FISH should be performed in all cases of breast tumour with a 2+ score by IHC. Cases demonstrating a 3+ score by IHC may be subjected to FISH to rule out polysomy of chromosome 17 which could be falsely interpreted as HER-2/neu overexpression by IHC analysis. There is also a need for establishing a clinically validated cut-off value

  12. Evaluation of HER-2/neu status in breast cancer specimens using immunohistochemistry (IHC) & fluorescence in-situ hybridization (FISH) assay

    PubMed Central

    Goud, Kalal Iravathy; Dayakar, Seetha; Vijayalaxmi, Kolanupaka; Babu, Saidam Jangu; Vijay, Anand Reddy P.

    2012-01-01

    Background & objectives: Fluorescence in situ hybridization (FISH) is increasingly being recognized as the most accurate and predictive test for HER2/neu gene amplification and response to therapy in breast cancer. In the present study we investigated HER-2/neu gene amplification by FISH in breast carcinoma tissue specimens and compared the results with that of immunohistochemical (IHC) analysis. Methods: A total of 90 breast carcinoma tissue samples were used for immunohistochemical (IHC) and FISH analysis. IHC was performed by using mouse monoclonal antibody to the intracellular domain of HER-2/neu protein. Each slide was scored in a blinded fashion by two pathologists according to the manufacturer's recommended criteria. FISH analysis was performed on paraffin embedded breast tumour tissue sections. The polysomy for centromere 17 (Spec green signal) was read as green signals less than 4 as moderate polysomy, and more than 4 as highly polysomy. Results: Thirty of the 90 patients had negative results by IHC and FISH. Of the 28 patients with the score of 2+ by IHC, 20 were FISH positive for HER-2/neu gene amplification, three were FISH negative and five patients showed equivocal (1.8-2.2) results by FISH. These five cases were retested for IHC and FISH on different paraffin embedded tissue blocks, and all five were found positive for HER-2/neu gene amplification. Twenty five patients with the score of 3+ by IHC were FISH positive for HER-2/neu gene amplification (>2.2). Seven cases with the score of 3+ by IHC were FISH negative for HER-2/neu gene amplification (>2.2), and showed polysomy of chromosome number 17 high polysomy > 4. Interpretation & conclusions: Our results indicated that HER-2/neu status by FISH should be performed in all cases of breast tumour with a 2+ score by IHC. Cases demonstrating a 3+ score by IHC may be subjected to FISH to rule out polysomy of chromosome 17 which could be falsely interpreted as HER-2/neu overexpression by IHC analysis

  13. Quantitative image analysis of immunohistochemical stains using a CMYK color model

    PubMed Central

    Pham, Nhu-An; Morrison, Andrew; Schwock, Joerg; Aviel-Ronen, Sarit; Iakovlev, Vladimir; Tsao, Ming-Sound; Ho, James; Hedley, David W

    2007-01-01

    Background Computer image analysis techniques have decreased effects of observer biases, and increased the sensitivity and the throughput of immunohistochemistry (IHC) as a tissue-based procedure for the evaluation of diseases. Methods We adapted a Cyan/Magenta/Yellow/Key (CMYK) model for automated computer image analysis to quantify IHC stains in hematoxylin counterstained histological sections. Results The spectral characteristics of the chromogens AEC, DAB and NovaRed as well as the counterstain hematoxylin were first determined using CMYK, Red/Green/Blue (RGB), normalized RGB and Hue/Saturation/Lightness (HSL) color models. The contrast of chromogen intensities on a 0–255 scale (24-bit image file) as well as compared to the hematoxylin counterstain was greatest using the Yellow channel of a CMYK color model, suggesting an improved sensitivity for IHC evaluation compared to other color models. An increase in activated STAT3 levels due to growth factor stimulation, quantified using the Yellow channel image analysis was associated with an increase detected by Western blotting. Two clinical image data sets were used to compare the Yellow channel automated method with observer-dependent methods. First, a quantification of DAB-labeled carbonic anhydrase IX hypoxia marker in 414 sections obtained from 138 biopsies of cervical carcinoma showed strong association between Yellow channel and positive color selection results. Second, a linear relationship was also demonstrated between Yellow intensity and visual scoring for NovaRed-labeled epidermal growth factor receptor in 256 non-small cell lung cancer biopsies. Conclusion The Yellow channel image analysis method based on a CMYK color model is independent of observer biases for threshold and positive color selection, applicable to different chromogens, tolerant of hematoxylin, sensitive to small changes in IHC intensity and is applicable to simple automation procedures. These characteristics are advantageous for both

  14. Mechanical Excitation of IHC Stereocilia: An Attempt to Fit Together Diverse Evidence

    NASA Astrophysics Data System (ADS)

    Guinan, John J.

    2011-11-01

    The output of the cochlea is controlled by the bending of inner-hair-cell (IHC) stereocilia, but the mechanisms that produce this bending are poorly understood. Relevant evidence comes from several sources: measurements of cochlear motion from in-vitro and live preparations, as well as inferences about cochlear motions from responses of auditory-nerve fibers. The common conception that IHC excitation is due to shearing between the reticular lamina (RL) and the tectorial membrane (TM) does not explain the data. A hypothesis is presented that fits many of the observations into a coherent picture of how IHCs are excited. The key new concept is that stretching of outer-hair-cell (OHC) stereocilia (defined broadly) changes the RL-TM gap and produces fluid flow within the gap that bends the IHC stereocilia. Changes in the RL-TM gap and the resulting bending of IHC stereocilia provide a mechanism by which OHC active processes can enhance cochlear output without a corresponding enhancement of basilar-membrane motion.

  15. Round-robin test for the cell-of-origin classification of diffuse large B-cell lymphoma-a feasibility study using full slide staining.

    PubMed

    Reinke, Sarah; Richter, Julia; Fend, Falko; Feller, Alfred; Hansmann, Martin-Leo; Hüttl, Katrin; Oschlies, Ilske; Ott, German; Möller, Peter; Rosenwald, Andreas; Stein, Harald; Altenbuchinger, Michael; Spang, Rainer; Klapper, Wolfram

    2018-05-05

    Diffuse large B-cell lymphoma (DLBCL) is subdivided by gene expression analysis (GEP) into two molecular subtypes named germinal center B-cell-like (GCB) and activated B-cell-like (ABC) after their putative cell-of-origin (COO). Determination of the COO is considered mandatory in any new-diagnosed DLBCL, not otherwise specified according to the updated WHO classification. Despite the fact that pathologists are free to choose the method for COO classification, immunohistochemical (IHC) assays are most widely used. However, to the best of our knowledge, no round-robin test to evaluate the interlaboratory variability has been published so far. Eight hematopathology laboratories participated in an interlaboratory test for COO classification of 10 DLBCL tumors using the IHC classifier comprising the expression of CD10, BCL6, and MUM1 (so-called Hans classifier). The results were compared with GEP for COO signature and, in a subset, with results obtained by image analysis. In 7/10 cases (70%), at least seven laboratories assigned a given case to the same COO subtype (one center assessed one sample as not analyzable), which was in agreement with the COO subtype determined by GEP. The results in 3/10 cases (30%) revealed discrepancies between centers and/or between IHC and GEP subtype. Whereas the CD10 staining results were highly reproducible, staining for MUM1 was inconsistent in 50% and for BCL6 in 40% of cases. Image analysis of 16 slides stained for BCL6 (N = 8) and MUM1 (N = 8) of the two cases with the highest disagreement in COO classification were in line with the score of the pathologists in 14/16 stainings analyzed (87.5%). This study describes the first round-robin test for COO subtyping in DLBCL using IHC and demonstrates that COO classification using the Hans classifier yields consistent results among experienced hematopathologists, even when variable staining protocols are used. Data from this small feasibility study need to be validated in larger

  16. Practical considerations of image analysis and quantification of signal transduction IHC staining.

    PubMed

    Grunkin, Michael; Raundahl, Jakob; Foged, Niels T

    2011-01-01

    The dramatic increase in computer processing power in combination with the availability of high-quality digital cameras during the last 10 years has fertilized the grounds for quantitative microscopy based on digital image analysis. With the present introduction of robust scanners for whole slide imaging in both research and routine, the benefits of automation and objectivity in the analysis of tissue sections will be even more obvious. For in situ studies of signal transduction, the combination of tissue microarrays, immunohistochemistry, digital imaging, and quantitative image analysis will be central operations. However, immunohistochemistry is a multistep procedure including a lot of technical pitfalls leading to intra- and interlaboratory variability of its outcome. The resulting variations in staining intensity and disruption of original morphology are an extra challenge for the image analysis software, which therefore preferably should be dedicated to the detection and quantification of histomorphometrical end points.

  17. A matrix approach to guide IHC-based tissue biomarker development in oncology drug discovery.

    PubMed

    Smith, Neil R; Womack, Christopher

    2014-01-01

    Immunohistochemistry (IHC) is a core platform for the analysis of tissue samples, and there is an increasing demand for reliable and quantitative IHC-based tissue biomarkers in oncology clinical research and development (R&D) environments. Biomarker assay and drug development proceed in parallel. Furthermore, biomarker assay requirements change with each phase of drug development. We have therefore developed a matrix tool to enable researchers to evaluate whether a particular IHC biomarker assay is fit for purpose. Experience gained from the development of 130 IHC biomarkers, supporting a large number of oncology drug projects, was used to formulate a practical approach to IHC assay development. The resultant matrix grid and accompanying work flow incorporates 16 core decision points that link antibody and assay specificity and sensitivity, and assay performance in preclinical and clinical samples, with stages of drug development. The matrix provides a means to ensure that relevant information on an IHC assay in development is recorded and communicated consistently and that minimum assay validation requirements are met. Copyright © 2013 Pathological Society of Great Britain and Ireland. Published by John Wiley & Sons, Ltd.

  18. Validation of the IHC4 Breast Cancer Prognostic Algorithm Using Multiple Approaches on the Multinational TEAM Clinical Trial.

    PubMed

    Bartlett, John M S; Christiansen, Jason; Gustavson, Mark; Rimm, David L; Piper, Tammy; van de Velde, Cornelis J H; Hasenburg, Annette; Kieback, Dirk G; Putter, Hein; Markopoulos, Christos J; Dirix, Luc Y; Seynaeve, Caroline; Rea, Daniel W

    2016-01-01

    Hormone receptors HER2/neu and Ki-67 are markers of residual risk in early breast cancer. An algorithm (IHC4) combining these markers may provide additional information on residual risk of recurrence in patients treated with hormone therapy. To independently validate the IHC4 algorithm in the multinational Tamoxifen Versus Exemestane Adjuvant Multicenter Trial (TEAM) cohort, originally developed on the trans-ATAC (Arimidex, Tamoxifen, Alone or in Combination Trial) cohort, by comparing 2 methodologies. The IHC4 biomarker expression was quantified on TEAM cohort samples (n = 2919) by using 2 independent methodologies (conventional 3,3'-diaminobezidine [DAB] immunohistochemistry with image analysis and standardized quantitative immunofluorescence [QIF] by AQUA technology). The IHC4 scores were calculated by using the same previously established coefficients and then compared with recurrence-free and distant recurrence-free survival, using multivariate Cox proportional hazards modeling. The QIF model was highly significant for prediction of residual risk (P < .001), with continuous model scores showing a hazard ratio (HR) of 1.012 (95% confidence interval [95% CI]: 1.010-1.014), which was significantly higher than that for the DAB model (HR: 1.008, 95% CI: 1.006-1.009); P < .001). Each model added significant prognostic value in addition to recognized clinical prognostic factors, including nodal status, in multivariate analyses. Quantitative immunofluorescence, however, showed more accuracy with respect to overall residual risk assessment than the DAB model. The use of the IHC4 algorithm was validated on the TEAM trial for predicting residual risk in patients with breast cancer. These data support the use of the IHC4 algorithm clinically, but quantitative and standardized approaches need to be used.

  19. Ber-H2 (CD30) immunohistochemical staining in malignant melanoma.

    PubMed

    Polski, J M; Janney, C G

    1999-09-01

    Malignant melanoma can be included in the differential diagnosis of Hodgkin's disease, anaplastic large cell lymphoma, or embryonal carcinoma These malignancies express CD30, a marker of diagnostic value. A retrospective immunohistochemical study was undertaken to determine the frequency of immunoreactivity of Ber-H2 (anti-CD30 monoclonal antibody) in malignant melanoma Archival paraffin-embedded tissue from 24 primary and metastatic lesions was used. No Ber-H2 labeling was observed in the majority of the studied cases. Variable weak cytoplasmic staining was present in only one case. The findings are compared with the previous reports claiming frequent CD30 expression in malignant melanoma. We discuss issues pertaining to the interpretation of the Ber-H2 IHC staining in formalin-fixed, paraffin-embedded tissue.

  20. Effectiveness of Vascular Markers (Immunohistochemical Stains) in Soft Tissue Sarcomas.

    PubMed

    Naeem, Namra; Mushtaq, Sajid; Akhter, Noreen; Hussain, Mudassar; Hassan, Usman

    2018-05-01

    To ascertain the effectiveness of IHC markers of vascular origin like CD31, CD34, FLI1 and ERG in vascular soft tissue sarcomas including angiosarcomas, Kaposi sarcomas, epithelioid hemangioendothelioma and a non-vascular soft tissue sarcoma (Epithelioid sarcoma). Descriptive study. Shaukat Khanum Memorial Cancer Hospital and Research Centre, Lahore, from 2011 to 2017. Diagnosed cases of angiosarcomas (n=48), epithelioid hemangioendothelioma (n=9), Kaposi sarcoma (n=9) and epithelioid sarcoma (n=20) were selected. Immunohistochemical staining as performed on formalin fixed paraffin embedded sections. The sections were stained for the following markers: CD34 (VENTANA clone Q Bend 10), CD31 (Leica clone 1 A 10), FLI1 (CELL MARQUE clone MRQ-1) and ERG (CELL MARQUE clone EP111). A complete panel of CD34, CD31 and ERG was applied on 8/48 cases of angiosarcomas with triple positivity in 6 cases. Eight cases showed positivity for only CD31 and ERG and 2 cases showed positivity for only ERG. A complete panel of CD34, CD31 and ERG was applied on 3/9 cases of epithelioid hemangioendothelioma with positivity for all markers in 2 cases. Combined positivity for ERG and CD34 was seen in 2 cases and on 4 cases only CD31 immunohistochemical was solely applied with 100% positivity. FLI1 was not applied on any case. Among 9 cases of Kaposi sarcoma, ERG, CD34 and CD31 in combination were applied on only 1 case with triple positivity. Remaining cases show positivity for either CD34, CD31 or FLI1. Majority of cases of epithelioid sarcomas were diagnosed on the basis of cytokeratin and CD34 positivity with loss of INI1. The other vascular markers showed negativity in all cases. Among these four markers, ERG immunohistochemical stain is highly effective for endothelial differentiation due to its specific nuclear staining pattern in normal blood vessel endothelial cells (internal control) as well as neoplastic cells of vascular tumors and lack of background staining.

  1. Collagen VII deficient mice show morphologic and histologic corneal changes that phenotypically mimic human dystrophic epidermolysis bullosa of the eye.

    PubMed

    Chen, Vicki M; Shelke, Rajani; Nyström, Alexander; Laver, Nora; Sampson, James F; Zhiyi, Cao; Bhat, Najma; Panjwani, Noorjahan

    2018-06-16

    Absence of collagen VII causes blistering of the skin, eyes and many other tissues. This disease is termed dystrophic epidermolysis bullosa (DEB). Corneal fibrosis occurs in up to 41% and vision loss in up to 64% of patients. Standard treatments are supportive and there is no cure. The immune-histologic and morphologic changes in the corneas of the mouse model for this disease have not been described in the literature. Our purpose is to characterize the eyes of these mice to determine if this is an appropriate model for study of human therapeutics. Western blot analysis (WB) and immunohistochemistry (IHC) were performed to assess the relative collagen VII protein levels and its location within the cornea. Additional IHC for inflammatory and fibrotic biomarkers alpha-smooth muscle actin (α-SMA), transforming growth factor-beta (TGF-β), connective tissue growth factor (CTGF), proteinase 3, tenascin C and collagen III were performed. Clinical photographs documenting opacification of the corneas of animals of differing ages were assessed and scored independently by 2 examiners. Histology was then used to investigate morphologic changes. IHC and WB confirmed that these mice are deficient in collagen VII production at the level of the basement membrane when compared with wild-types. IHC showed anomalous deposition of collagen III throughout the stroma. Of the 5 biomarkers tested, TGF-β showed the strongest and most consistently staining. Photographs documented corneal opacities only in mice older than 10 weeks, opacities were not seen in younger animals. Histology showed multiple abnormalities, including epithelial hyperplasia, ulceration, fibrosis, edema, dysplasia, neovascularization and bullae formation. The collagen VII hypomorphic mouse shows reduced collagen VII production at the level of the corneal basement membrane. Corneal changes are similar to pathology seen in humans with this disease. The presence of anomalous stromal collagen III and TGF-β appear to be

  2. ALK status testing in non-small cell lung carcinoma: correlation between ultrasensitive IHC and FISH.

    PubMed

    Minca, Eugen C; Portier, Bryce P; Wang, Zhen; Lanigan, Christopher; Farver, Carol F; Feng, Yan; Ma, Patrick C; Arrossi, Valeria A; Pennell, Nathan A; Tubbs, Raymond R

    2013-05-01

    ALK gene rearrangements in advanced non-small cell lung carcinomas (NSCLC) are an indication for targeted therapy with crizotinib. Fluorescence in situ hybridization (FISH) using a recently approved companion in vitro diagnostic class FISH system commonly assesses ALK status. More accessible IHC is challenged by low expression of ALK-fusion transcripts in NSCLC. We compared ultrasensitive automated IHC with FISH for detecting ALK status on 318 FFPE and 40 matched ThinPrep specimens from 296 patients with advanced NSCLC. IHC was concordant with FFPE-FISH on 229 of 231 dual-informative samples (31 positive and 198 negative) and with ThinPrep-FISH on 34 of 34 samples (5 positive and 29 negative). Two cases with negative IHC and borderline-positive FFPE-FISH (15% and 18%, respectively) were reclassified as concordant based on negative matched ThinPrep-FISH and clinical data consistent with ALK-negative status. Overall, after including ThinPrep-FISH and amending the false-positive FFPE-FISH results, IHC demonstrated 100% sensitivity and specificity (95% CI, 0.86 to 1.00 and 0.97 to 1.00, respectively) for ALK detection on 249 dual-informative NSCLC samples. IHC was informative on significantly more samples than FFPE-FISH, revealing additional ALK-positive cases. The high concordance with FISH warrants IHC's routine use as the initial component of an algorithmic approach to clinical ALK testing in NSCLC, followed by reflex FISH confirmation of IHC-positive cases. Copyright © 2013 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  3. Diffuse Staining for Activated NOTCH1 Correlates With NOTCH1 Mutation Status and Is Associated With Worse Outcome in Adenoid Cystic Carcinoma.

    PubMed

    Sajed, Dipti P; Faquin, William C; Carey, Chris; Severson, Eric A; H Afrogheh, Amir; A Johnson, Carl; Blacklow, Stephen C; Chau, Nicole G; Lin, Derrick T; Krane, Jeffrey F; Jo, Vickie Y; Garcia, Joaquín J; Sholl, Lynette M; Aster, Jon C

    2017-11-01

    NOTCH1 is frequently mutated in adenoid cystic carcinoma (ACC). To test the idea that immunohistochemical (IHC) staining can identify ACCs with NOTCH1 mutations, we performed IHC for activated NOTCH1 (NICD1) in 197 cases diagnosed as ACC from 173 patients. NICD1 staining was positive in 194 cases (98%) in 2 major patterns: subset positivity, which correlated with tubular/cribriform histology; and diffuse positivity, which correlated with a solid histology. To determine the relationship between NICD1 staining and NOTCH1 mutational status, targeted exome sequencing data were obtained on 14 diffusely NICD1-positive ACC specimens from 11 patients and 15 subset NICD1-positive ACC specimens from 15 patients. This revealed NOTCH1 gain-of-function mutations in 11 of 14 diffusely NICD1-positive ACC specimens, whereas all subset-positive tumors had wild-type NOTCH1 alleles. Notably, tumors with diffuse NICD1 positivity were associated with significantly worse outcomes (P=0.003). To determine whether NOTCH1 activation is unique among tumors included in the differential diagnosis with ACC, we performed NICD1 IHC on a cohort of diverse salivary gland and head and neck tumors. High fractions of each of these tumor types were positive for NICD1 in a subset of cells, particularly in basaloid squamous cell carcinomas; however, sequencing of basaloid squamous cell carcinomas failed to identify NOTCH1 mutations. These findings indicate that diffuse NICD1 positivity in ACC correlates with solid growth pattern, the presence of NOTCH1 gain-of-function mutations, and unfavorable outcome, and suggest that staining for NICD1 can be helpful in distinguishing ACC with solid growth patterns from other salivary gland and head and neck tumors.

  4. Clinical utility of RT-PCR in assessing HER 2 gene expression versus traditional IHC and FISH in breast cancer patients.

    PubMed

    Suryavanshi, Moushumi; Mehta, Anurag; Jaipuria, Jiten; Kumar, Dushyant; Vishwakarma, Gayatri; Panigrahi, Manoj Kumar; Verma, Haristuti; Saifi, Mumtaz; Sharma, Sanjeev; Tandon, Simran; Doval, D C; Das, Bhudev C

    2018-02-09

    IHC and FISH are used for categorizing HER 2 status in breast cancer at the protein and DNA level, respectively. HER 2 expression at the RNA level is quantitative, cheaper, easier to standardize and free from interobserver variation. 115 consecutive patients were tested by IHC, FISH and RT-PCR (test cohort). Assuming FISH result to be the response variable, ROC curves for RT-PCR ratio were analyzed to label HER 2 negative, equivocal and positive cases as RT-PCR score 1, 2 and 3, respectively. Inter-relationships between RT-PCR, IHC and FISH were defined. 'Clinical benefit' of a test was defined as proportion of patients labeled unequivocally as HER 2 positive or negative. Population for 1 year was simulated constraint to previous reports of HER 2 positivity and IHC category distribution by a meta-analysis of previous studies that evaluated concordance between IHC and FISH to determine HER 2 status (simulation cohort). Four diagnostic pathways in the simulation cohort were defined-(1) initial IHC, followed by FISH (conventional pathway); (2) initial RT-PCR, followed by FISH; (3) initial IHC, followed by RT-PCR and then by FISH; (4) initial RT-PCR, followed by IHC and then by FISH. The clinical benefit of IHC and RT-PCR in the four pathways was analyzed and sensitivity analysis for incremental cost-effectiveness ratio and cost-benefit comapring RT-PCR against IHC, both as first-line tests and among those with IHC score 2 as a reflex second-line test was performed by the Monte Carlo technique. 115 patients comprised the study population. While none with IHC score of 0 or 1 was FISH positive for HER 2, all cases with IHC score of 3 were FISH positive. 43 cases were assigned IHC score of 2. Thus, 72 patients benefited from the initial IHC testing [clinical benefit 62.6%], with the overall concordance between IHC and FISH being 100% for those with IHC score of 0, 1 and 3 (conclusive IHC categories). For RT-PCR with 100% concordance, 15.7% (115-97 = 18) patients

  5. Steroidogenic Factor 1, Pit-1, and Adrenocorticotropic Hormone: A Rational Starting Place for the Immunohistochemical Characterization of Pituitary Adenoma.

    PubMed

    McDonald, William C; Banerji, Nilanjana; McDonald, Kelsey N; Ho, Bridget; Macias, Virgilia; Kajdacsy-Balla, Andre

    2017-01-01

    -Pituitary adenoma classification is complex, and diagnostic strategies vary greatly from laboratory to laboratory. No optimal diagnostic algorithm has been defined. -To develop a panel of immunohistochemical (IHC) stains that provides the optimal combination of cost, accuracy, and ease of use. -We examined 136 pituitary adenomas with stains of steroidogenic factor 1 (SF-1), Pit-1, anterior pituitary hormones, cytokeratin CAM5.2, and α subunit of human chorionic gonadotropin. Immunohistochemical staining was scored using the Allred system. Adenomas were assigned to a gold standard class based on IHC results and available clinical and serologic information. Correlation and cluster analyses were used to develop an algorithm for parsimoniously classifying adenomas. -The algorithm entailed a 1- or 2-step process: (1) a screening step consisting of IHC stains for SF-1, Pit-1, and adrenocorticotropic hormone; and (2) when screening IHC pattern and clinical history were not clearly gonadotrophic (SF-1 positive only), corticotrophic (adrenocorticotropic hormone positive only), or IHC null cell (negative-screening IHC), we subsequently used IHC for prolactin, growth hormone, thyroid-stimulating hormone, and cytokeratin CAM5.2. -Comparison between diagnoses generated by our algorithm and the gold standard diagnoses showed excellent agreement. When compared with a commonly used panel using 6 IHC for anterior pituitary hormones plus IHC for a low-molecular-weight cytokeratin in certain tumors, our algorithm uses approximately one-third fewer IHC stains and detects gonadotroph adenomas with greater sensitivity.

  6. The role of immunohistochemical analysis in the evaluation of EML4-ALK gene rearrangement in lung cancer.

    PubMed

    Sullivan, Harold C; Fisher, Kevin E; Hoffa, Anne L; Wang, Jason; Saxe, Debra; Siddiqui, Momin T; Cohen, Cynthia

    2015-04-01

    Among the mutations described in non-small cell lung carcinoma is a rearrangement resulting from an inversion within chromosome 2p leading to the formation of a fusion gene, echinoderm microtubule-associated protein-like 4-anaplastic lymphoma kinase (EML4-ALK). Fluorescence in situ hybridization (FISH) is the gold standard for the detection of ALK gene rearrangements. However, molecular methods are not readily available in all pathology laboratories. Immunohistochemistry (IHC) using an antibody directed against the EML4-ALK fusion protein provides a widely available alternative method of detection. We assessed whether IHC is a comparable and cost-effective alternative to FISH analysis for the detection of ALK gene rearrangements. A total of 110 non-small cell lung carcinoma cases (63 surgical/biopsy and 47 cytology specimens), previously tested for ALK gene rearrangements by FISH [7 (6.4%) positive for the rearrangement], were probed for the EML4-ALK fusion protein using a monoclonal EML4-ALK antibody, clone 5A4. Cells were considered to stain positive for ALK if >5% of cells showed cytoplasmic staining of at least grade 1 intensity (scale: 0 to 3). A cost analysis was performed using ALK IHC as a screening test. The sensitivity and specificity of the EML4-ALK IHC stain compared with ALK FISH analysis were 100% and 96%, respectively. All 7 FISH-positive cases stained positive by IHC, whereas 4 FISH-negative cases demonstrated positive staining. One of the 4 FISH-negative, IHC-positive cases harbored an EML4-ALK rearrangement by RT-PCR yielding 3 false-positive results overall. The κ agreement between IHC and FISH methods is 0.76 (substantial/excellent). The potential savings of implementing the ALK IHC as a screening method would be $10,418.21. Sensitivity of the EML4-ALK IHC stain is excellent (100%) but due to its suboptimal specificity, IHC cannot reliably supplant FISH analysis for the detection of ALK gene rearrangements. IHC shows promise as a screening tool

  7. Intrafocal heterogeneity of ERG protein expression and gene fusion pattern in prostate cancer.

    PubMed

    Suh, Ja Hee; Park, Jeong Hwan; Lee, Cheol; Moon, Kyung Chul

    2017-10-01

    Prostate cancer is considered to be highly heterogeneous, with various morphologic features and biologic behaviors. The TMPRSS2-ERG gene fusion is the most frequently observed genetic aberration in prostate cancer. The aim of this study was to elucidate the intrafocal heterogeneity of ERG gene fusion status. ERG immunohistochemistry (IHC) was performed in samples from 168 prostate cancer patients who had undergone radical prostatectomy, and 40 cases showing ERG-positive IHC staining were selected for tissue microarray (TMA) construction. Two to six representative cores were selected from each tumor focus. In the cases with heterogeneous ERG IHC staining intensity, the areas showing different intensities were separately selected. Using the TMA blocks, IHC and fluorescence in situ hybridization (FISH) were conducted to evaluate the heterogeneity of ERG protein expression and ERG fusion gene patterns, respectively, in a single tumor focus. Heterogeneity of ERG IHC staining was defined as the simultaneous presence of negative and positive cores in the same tumor focus. Heterogeneity of ERG FISH was defined by the presence of cores with positive and negative FISH signals or cores with break-apart and interstitial deletion FISH signals in the same tumor focus. A total of 202 TMA cores were isolated from 40 ERG-positive cases. Of the 202 total cores, 19 were negative for ERG IHC staining, and 46 showed 1+, 52 showed 2+, and 85 showed 3+ ERG staining intensity. Eleven cores were negative for ERG FISH signal, 119 cores showed ERG break-apart FISH signals, and the remaining 72 cores revealed interstitial deletion. Intrafocal heterogeneity of ERG IHC staining was found in 20% (8/40) of cases, and intrafocal heterogeneity of ERG gene fusion pattern was found in 32.5% (13/40) of cases. In summary, this study showed significantly frequent intrafocal heterogeneity of ERG protein expression, gene fusion status and fusion pattern. This heterogeneity can be caused by the development

  8. Levey-Jennings Analysis Uncovers Unsuspected Causes of Immunohistochemistry Stain Variability.

    PubMed

    Vani, Kodela; Sompuram, Seshi R; Naber, Stephen P; Goldsmith, Jeffrey D; Fulton, Regan; Bogen, Steven A

    Almost all clinical laboratory tests use objective, quantitative measures of quality control (QC), incorporating Levey-Jennings analysis and Westgard rules. Clinical immunohistochemistry (IHC) testing, in contrast, relies on subjective, qualitative QC review. The consequences of using Levey-Jennings analysis for QC assessment in clinical IHC testing are not known. To investigate this question, we conducted a 1- to 2-month pilot test wherein the QC for either human epidermal growth factor receptor 2 (HER-2) or progesterone receptor (PR) in 3 clinical IHC laboratories was quantified and analyzed with Levey-Jennings graphs. Moreover, conventional tissue controls were supplemented with a new QC comprised of HER-2 or PR peptide antigens coupled onto 8 μm glass beads. At institution 1, this more stringent analysis identified a decrease in the HER-2 tissue control that had escaped notice by subjective evaluation. The decrement was due to heterogeneity in the tissue control itself. At institution 2, we identified a 1-day sudden drop in the PR tissue control, also undetected by subjective evaluation, due to counterstain variability. At institution 3, a QC shift was identified, but only with 1 of 2 controls mounted on each slide. The QC shift was due to use of the instrument's selective reagent drop zones dispense feature. None of these events affected patient diagnoses. These case examples illustrate that subjective QC evaluation of tissue controls can detect gross assay failure but not subtle changes. The fact that QC issues arose from each site, and in only a pilot study, suggests that immunohistochemical stain variability may be an underappreciated problem.

  9. Mixture of learners for cancer stem cell detection using CD13 and H and E stained images

    NASA Astrophysics Data System (ADS)

    Oǧuz, Oǧuzhan; Akbaş, Cem Emre; Mallah, Maen; Taşdemir, Kasım.; Akhan Güzelcan, Ece; Muenzenmayer, Christian; Wittenberg, Thomas; Üner, Ayşegül; Cetin, A. E.; ćetin Atalay, Rengül

    2016-03-01

    In this article, algorithms for cancer stem cell (CSC) detection in liver cancer tissue images are developed. Conventionally, a pathologist examines of cancer cell morphologies under microscope. Computer aided diagnosis systems (CAD) aims to help pathologists in this tedious and repetitive work. The first algorithm locates CSCs in CD13 stained liver tissue images. The method has also an online learning algorithm to improve the accuracy of detection. The second family of algorithms classify the cancer tissues stained with H and E which is clinically routine and cost effective than immunohistochemistry (IHC) procedure. The algorithms utilize 1D-SIFT and Eigen-analysis based feature sets as descriptors. Normal and cancerous tissues can be classified with 92.1% accuracy in H and E stained images. Classification accuracy of low and high-grade cancerous tissue images is 70.4%. Therefore, this study paves the way for diagnosing the cancerous tissue and grading the level of it using H and E stained microscopic tissue images.

  10. Simultaneous VENTANA IHC and RT-PCR testing of ALK status in Chinese non-small cell lung cancer patients and response to crizotinib.

    PubMed

    Xu, Chun-Wei; Wang, Wen-Xian; Chen, Yan-Ping; Chen, Yu; Liu, Wei; Zhong, Li-Hua; Chen, Fang-Fang; Zhuang, Wu; Song, Zheng-Bo; Chen, Xiao-Hui; Huang, Yun-Jian; Guan, Yan-Fang; Yi, Xin; Lv, Tang-Feng; Zhu, Wei-Feng; Lu, Jian-Ping; Wang, Xiao-Jiang; Shi, Yi; Lin, Xian-Dong; Chen, Gang; Song, Yong

    2018-04-11

    ALK rearrangement-advanced NSCLC patients respond to crizotinib. ALK rearrangement is currently determined with RT-PCR. VENTANA IHC is a standard method to identify ALK protein overexpression in NSCLC; however, VENTANA IHC has rarely been used to determine the response to crizotinib in Chinese patients with NSCLC and ALK overexpression. To better clarify the clinical implication of VENTANA IHC to detect ALK rearrangements, we conducted this study to analyze VENTANA IHC and RT-PCR in a large cohort of Chinese patients with NSCLC undergoing screening for ALK rearrangements. A total of 1720 patients with NSCLC who had ALK rearrangements detected by VENTANA IHC and/or RT-PCR were included in this analysis. We compared the efficacy and survival of ALK-positive patients detected by VENTANA IHC and RT-PCR. We used NGS to identify patients in whom the two methods were inconsistent. Among 1720 patients, 187 (10.87%) were shown to be ALK-positive by VENTANA IHC and/or RT-PCR, and 66 received crizotinib treatment. We identified 10.27% (172/1674) of patients as ALK-positive by the VENTANA IHC method, and 12.73% (41/322) of patients had ALK rearrangements by the RT-PCR method. Twenty-nine of 276 (10.51%) ALK-positive patients were simultaneously analyzed using VENTANA IHC and RT-PCR. The overall response rates were 65.90% (29/44) by VENTANA IHC and 55.88% (19/34) by RT-PCR. The disease control rates were 86.36% (38/44) by VENTANA IHC and 76.47% (26/34) by RT-PCR. In contrast, the median progression-free survival for VENTANA IHC and RT-PCR was 8.5 and 9.2 months, respectively. The VENTANA IHC and RT-PCR results obtained for 6 of 17 ALK-positive patients were inconsistent based on NGS; specifically, 4 patients had EML4-ALK fusions, 2 patients had non EML4-ALK fusions, 1 patient had a KCL1-ALK fusion, and one patient had a FBXO36-ALK fusion. VENTANA IHC is a reliable and rapid screening tool used in routine pathologic laboratories for the identification of suitable candidates for

  11. Modified Field's staining--a rapid stain for Trichomonas vaginalis.

    PubMed

    Afzan, M Yusuf; Sivanandam, S; Kumar, G Suresh

    2010-10-01

    Trichomonas vaginalis, a flagellate protozoan parasite commonly found in the human genitourinary tract, is transmitted primarily by sexual intercourse. Diagnosis is usually by in vitro culture method and staining with Giemsa stain. There are laboratories that use Gram stain as well. We compared the use of modified Field's (MF), Giemsa, and Gram stains on 2 axenic and xenic isolates of T. vaginalis, respectively. Three smears from every sediment of spun cultures of all 4 isolates were stained, respectively, with each of the stains. We showed that MF staining, apart from being a rapid stain (20 s), confers sharper staining contrast, which differentiates the nucleus and the cytoplasm of the organism when compared to Giemsa and Gram staining especially on parasites from spiked urine samples. The alternative staining procedure offers in a diagnostic setting a rapid stain that can easily visualize the parasite with sharp contrasting characteristics between organelles especially the nucleus and cytoplasm. Vacuoles are more clearly visible in parasites stained with MF than when stained with Giemsa. Copyright © 2010 Elsevier Inc. All rights reserved.

  12. Usability of Immunohistochemistry in Forensic Samples With Varying Decomposition.

    PubMed

    Lesnikova, Iana; Schreckenbach, Marc Niclas; Kristensen, Maria Pihlmann; Papanikolaou, Liv Lindegaard; Hamilton-Dutoit, Stephen

    2018-05-24

    Immunohistochemistry (IHC) is an important diagnostic tool in anatomic and surgical pathology but is used less frequently in forensic pathology. Degradation of tissue because of postmortem decomposition is believed to be a major limiting factor, although it is unclear what impact such degradation actually has on IHC staining validity. This study included 120 forensic autopsy samples of liver, lung, and brain tissues obtained for diagnostic purposes. The time from death to autopsy ranged between 1 and more than 14 days. Samples were prepared using the tissue microarray technique. The antibodies chosen for the study included KL1 (for staining bile duct epithelium), S100 (for staining glial cells and myelin), vimentin (for endothelial cells in cerebral blood vessels), and CD45 (for pulmonary lymphocytes). Slides were evaluated by light microscopy. Immunohistochemistry reactions were scored according to a system based on the extent and intensity of the positive stain. An overall correlation between the postmortem interval and the IHC score for all tissue samples was found. Samples from decedents with a postmortem interval of 1 to 3 days showed positive staining with all antibodies, whereas samples from decedents with a longer postmortem interval showed decreased staining rates. Our results suggest that IHC analysis can be successfully used for postmortem diagnosis in a range of autopsy samples showing lesser degrees of decomposition.

  13. Mass spectrometry-based quantitation of Her2 in gastroesophageal tumor tissue: Comparison to IHC and FISH

    PubMed Central

    Catenacci, Daniel V.T.; Liao, Wei-Li; Zhao, Lei; Whitcomb, Emma; Henderson, Les; O’Day, Emily; Xu, Peng; Thyparambil, Sheeno; Krizman, David; Bengali, Kathleen; Uzzell, Jamar; Darfler, Marlene; Cecchi, Fabiola; Blackler, Adele; Bang, Yung-Jue; Hart, John; Xiao, Shu-Yuan; Lee, Sang Mee; Burrows, Jon; Hembrough, Todd

    2015-01-01

    Background Trastuzumab showed survival benefit for Her2-positive gastroesophageal cancers (GEC). Immunohistochemistry (IHC) and fluorescence in situ hybridization (FISH) currently determine eligibility for trastuzumab-based therapy. However, these low-throughput assays often produce discordant or equivocal results. Methods We developed a targeted proteomic assay based on selected reaction monitoring mass spectrometry (SRM-MS) and quantified levels (amol/ug) of Her2-SRM protein in cell lines (n=27) and GEC tissues (n=139). We compared Her2-SRM protein expression with IHC/FISH, seeking to determine optimal SRM protein expression cut-offs to identify HER2 gene amplification. Results After demonstrating assay development, precision, and stability, Her2-SRM protein measurement was observed to be highly concordant with HER2/CEP17 ratio, particularly in a multivariate regression model adjusted for SRM-expression of Met, Egfr, Her3, and HER2-heterogeneity covariates, and their interactions (cell lines r2=0.9842; FFPE r2=0.7643). In GEC tissues, Her2-SRM protein was detected in 71.2% of cases. ROC curves demonstrated Her2-SRM protein levels to have high specificity (100%) at an upper-level cut-off of >750 amol/μg and sensitivity (75%) at lower-level cut-off of <450 amol/ug to identify HER2 FISH amplified tumors. An ‘equivocal-zone’ of 450-750 amol/ug of Her2-SRM protein was analogous to ’IHC2+#x2019;, but represented fewer cases (9-16% of cases versus 36-41%). Conclusions Compared to IHC, targeted SRM-Her2 proteomics provided more objective and quantitative Her2 expression with excellent HER2/CEP17 FISH correlation and fewer equivocal cases. Along with the multiplex capability for other relevant oncoproteins, these results demonstrated a refined HER2 protein expression assay for clinical application. PMID:26581548

  14. Immunohistochemical findings of the granulomatous reaction associated with tuberculosis.

    PubMed

    Karimi, Shirin; Shamaei, Masoud; Pourabdollah, Mihan; Sadr, Makan; Karbasi, Mehrdad; Kiani, Arda; Bahadori, Moslem

    2016-12-01

    The histological diagnosis of Mycobacterium tuberculosis (MTB) has long been a diagnostic challenge in the anatomical pathology field despite availability of different laboratory methods. Immunohistochemistry (IHC) could not only confirm granulomatous tissue involvement but also demonstrate MTB antigen immunolocalization. This study tries to clarify the details of IHC staining for MTB with pAbBCG. A total of 50 patients undergoing simultaneous biopsy and tissue culture with positive tissue culture for MTB during 2005-2009 were selected from the MRC Department at Masih Daneshvari Hospital, Tehran, Iran. Using the archives of the Pathology Department of this hospital, which is a referral center for pathological lung lesions, hematoxylin and eosin slides of the selected patients were evaluated. Twenty-three confirmed TB granulomatous tissue samples with adequate tissue and number of granulomas were chosen and studied by Ziehl-Neelsen and IHC staining with pAbBCG. A total of 23 cases were evaluated, of which 17 (73.9%) were males. The types of tissue obtained from study cases were as follows: pleura (9 cases, 39.1%), lymph node (cervical, axillary, and thoracic [9 cases, 39.1%]), and lung tissues (5 cases, 21.7%). IHC staining was positive in all samples, whereas Ziehl-Neelsen staining was positive in nine cases of 23 (39.1%). IHC showed positive coarse granular cytoplasmic and round, fragmented bacillary staining. In this study, epithelioid cells clearly showed more positive staining at the periphery rather than at the center of granuloma. There is also positive staining in endothelial cells, fibroblasts, plasma cells, macrophages, and lymphocytes outside the granuloma. Detection of TB in tissue slides is still based on the histological pattern of the granuloma, which has several differential diagnoses with different treatments. Presence of mycobacterial antigens and tissue morphology can be evaluated using the IHC technique. Considering the criteria of positive IHC

  15. Intratumoral and peritumoral lymphovascular invasion detected by D2-40 immunohistochemistry correlates with metastasis in primary cutaneous Merkel cell carcinoma.

    PubMed

    Al-Rohil, Rami N; Milton, Denái R; Nagarajan, Priyadharsini; Curry, Jonathan L; Feldmeyer, Laurence; Torres-Cabala, Carlos A; Ivan, Doina; Prieto, Victor G; Tetzlaff, Michael T; Aung, Phyu P

    2018-07-01

    Primary cutaneous Merkel cell carcinoma (MCC) is an aggressive neuroendocrine malignancy in which lymphovascular invasion (LVI) correlates with more aggressive phenotype. The prognostic significance of LVI detected by D2-40 immunohistochemistry (IHC) in MCC remains controversial. We aimed to determine how LVI detected by D2-40 IHC compares with LVI detected by hematoxylin and eosin (H&E) staining in predicting MCC metastasis. Clinical and histopathologic features of MCCs diagnosed and treated in 2002 to 2015 were assembled and included 58 MCC tumors from 58 patients. H&E-stained tissue sections and D2-40 IHC studies were reviewed. When LVI was present, the location (peritumoral or intratumoral) and the size of the largest invaded vessel were recorded. LVI findings by H&E staining and D2-40 IHC were compared with each other and with histologic features and clinical outcomes. H&E staining showed LVI in 37 of 58 cases; D2-40 IHC confirmed LVI in 30 of these cases but failed to confirm LVI in 7. D2-40 IHC also detected 14 cases of LVI not identified on H&E staining. Histologically, D2-40-detected LVI was associated with infiltrative growth pattern and nonbrisk lymphoid infiltrate (P = .005 and P = .055, respectively). There was a statistically significant difference between the frequency of detection of peritumoral LVI by H&E in comparison to D2-40 IHC (P = .0009). MCCs in which D2-40 IHC-detected both intratumoral and peritumoral LVI were typically larger than MCCs without (mean, 24.5 mm versus 17.3 mm; P = .03) and more frequently metastasized (87% versus 51%; P = .03). D2-40 IHC detection of both intratumoral and peritumoral LVI is associated with metastasis. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. Hematoxylin and Eosin Counterstaining Protocol for Immunohistochemistry Interpretation and Diagnosis.

    PubMed

    Grosset, Andrée-Anne; Loayza-Vega, Kevin; Adam-Granger, Éloïse; Birlea, Mirela; Gilks, Blake; Nguyen, Bich; Soucy, Geneviève; Tran-Thanh, Danh; Albadine, Roula; Trudel, Dominique

    2017-12-21

    Hematoxylin and eosin (H&E) staining is a well-established technique in histopathology. However, immunohistochemistry (IHC) interpretation is done exclusively with hematoxylin counterstaining. Our goal was to investigate the potential of H&E as counterstaining (H&E-IHC) to allow for visualization of a marker while confirming the diagnosis on the same slide. The quality of immunostaining and the fast-technical performance were the main criteria to select the final protocol. We stained multiple diagnostic tissues with class I IHC tests with different subcellular localization markers (anti-CK7, CK20, synaptophysin, CD20, HMB45, and Ki-67) and with double-staining on prostate tissues with anti-high molecular weight keratins/p63 (DAB detection) and p504s (alkaline phosphatase detection). To validate the efficacy of the counterstaining, we stained tissue microarrays from the Canadian Immunohistochemistry Quality Control (cIQc) with class II IHC tests (ER, PR, HER2, and p53 markers). Interobserver and intraobserver concordance was assessed by κ statistics. Excellent agreement of H&E-IHC interpretation was observed in comparison with standard IHC from our laboratory (κ, 0.87 to 1.00), and with the cIQc reference values (κ, 0.81 to 1.00). Interobserver and intraobserver agreement was excellent (κ, 0.89 to 1.00 and 0.87 to 1.00, respectively). We therefore show for the first time the potential of using H&E counterstaining for IHC interpretation. We recommend the H&E-IHC protocol to enhance diagnostic precision for the clinical workflow and research studies.

  17. Diagnostic value of a novel fully automated immunochemistry assay for detection of ALK rearrangement in primary lung adenocarcinoma.

    PubMed

    Ying, J; Guo, L; Qiu, T; Shan, L; Ling, Y; Liu, X; Lu, N

    2013-10-01

    To evaluate the diagnostic value of a novel fully automated immunohistochemistry (IHC) assay for detection of anaplastic lymphoma kinase (ALK) fusion in a large number of ALK-positive lung adenocarcinoma (ADC) patients. We tested 196 lung ADCs for ALK rearrangement by two IHC assays (Ventana pre-diluted ALK D5F3 antibody with the Optiview DAB IHC detection kit and Optiview Amplification kit, D5F3 by Cell Signaling Technology (CST) with Ultraview DAB detection kit by Ventana), fluorescence in situ hybridization (FISH) and real-time reverse transcription-PCR (RT-PCR). CST ALK IHC was scored using the scoring scheme of 0, no staining; 1+, faint; 2+, moderate; and 3+, strong cytoplasmic reactivity in ≥ 10% of tumor cells. As for Ventana IHC, a binary scoring system (positive or negative for ALK status) was adopted for evaluating the staining results. Among 196 cases tested, 63 (32%), 65 (33%), 70 (36%), and 69 (35%) cases were ALK positive by FISH, Ventana IHC, CST IHC, and RT-PCR, respectively. The sensitivity and specificity of Ventana IHC were 100% and 98%, respectively. Two Ventana IHC-positive cases, which were also CST IHC score of 3+, showed FISH negative, but their ALK rearrangement was confirmed by RT-PCR and direct sequencing. The sensitivity and specificity of CST IHC with staining intensity score of 1+ or more were 100% and 95%, respectively. Five (25%, of 20) patients with CST IHC score of 1+ were both FISH and RT-PCR negative. The sensitivity and specificity of RT-PCR for detection of ALK fusion were 98% and 95%, respectively. The total accordance rate between ALK RT-PCR and Ventana IHC was 97%. The novel fully automated IHC assay is a reliable screening tool in routine pathologic laboratories for identification of patients with ALK rearrangement for targeted therapy in lung ADC.

  18. Concordance of IHC, FISH and RT-PCR for EML4-ALK rearrangements.

    PubMed

    Teixidó, Cristina; Karachaliou, Niki; Peg, Vicente; Gimenez-Capitan, Ana; Rosell, Rafael

    2014-04-01

    The echinoderm microtubule-associated protein-like 4 anaplastic lymphoma kinase (EML4-ALK) has emerged as the second most important driver oncogene in lung cancer and the first targetable fusion oncokinase to be identified in 4-6% of lung adenocarcinomas. Crizotinib, along with a diagnostic test-the Vysis ALK Break Apart fluorescence in situ hybridization (FISH) Probe Kit-is approved for the treatment of ALK positive advanced non-small cell lung cancer (NSCLC). However, the success of a targeted drug is critically dependent on a sensitive and specific screening assay to detect the molecular drug target. In our experience, reverse transcription polymerase chain reaction (RT-PCR)-based detection of EML4-ALK is a more sensitive and reliable approach compared to FISH and immunohistochemistry (IHC). Although ALK FISH is clinically validated, the assay can be technically challenging and other diagnostic modalities, including IHC and RT-PCR should be further explored.

  19. Molecular characterization of epithelioid haemangioendotheliomas identifies novel WWTR1-CAMTA1 fusion variants.

    PubMed

    Patel, Nimesh R; Salim, Alaa A; Sayeed, Hadi; Sarabia, Stephen F; Hollingsworth, Faith; Warren, Mikako; Jakacky, Jared; Tanas, Munir; Oliveira, Andre M; Rubin, Brian P; Lazar, Alexander J; López-Terrada, Dolores; Wang, Wei-Lien

    2015-11-01

    Epithelioid haemangioendothelioma (EHE) is a malignant vascular neoplasm. Subsets have been characterized previously by translocations resulting in either WWTR1-CAMTA1 or YAP1-TFE3 fusion. We sought to develop molecular and immunohistochemical (IHC) assays to aid in the diagnosis and characterization of EHE. Fifty-two formalin-fixed, paraffin-embedded (FFPE) cases diagnosed between 2002 and 2014 were retrieved from the pathology files of our institutions. Reverse transcription-polymerase chain reaction (RT-PCR) assays were optimized to detect WWTR1-CAMTA1 and YAP1-TFE3 fusion transcripts in FFPE tissue and transcription factor E3 (TFE3) protein accumulation was examined by immunohistochemistry (IHC). RNA was extracted from 33 adequate samples, with more recent cases providing a greater yield of high quality RNA. Fourteen of 18 informative cases were positive for WWTR1-CAMTA1 fusion transcripts, four of which showed higher-grade cytological features termed by some as 'malignant EHE'. Novel in-frame fusion transcripts were identified in four cases by direct sequencing. IHC revealed variable nuclear TFE3 staining in six of 17 cases; three with patchy staining showed WWTR1-CAMTA1 fusion. One of 18 informative cases was positive for YAP1-TFE3 fusion and showed strong nuclear TFE3 staining by IHC. This study confirms the high incidence of WWTR1-CAMTA1 and YAP1-TFE3 rearrangements in EHE and indicates that the staining pattern for TFE3 IHC is critical for specificity. © 2015 John Wiley & Sons Ltd.

  20. MYC Immunohistochemistry to Identify MYC-Driven B-Cell Lymphomas in Clinical Practice.

    PubMed

    Kluk, Michael J; Ho, Caleb; Yu, Hongbo; Chen, Benjamin J; Neuberg, Donna S; Dal Cin, Paola; Woda, Bruce A; Pinkus, Geraldine S; Rodig, Scott J

    2016-02-01

    Immunohistochemistry with anti-MYC antibody (MYC IHC) detects MYC protein in fixed samples of aggressive B-cell lymphomas and, according to the number of positive staining tumor nuclei, facilitates tumor subclassification, predicts underlying MYC rearrangements, and stratifies patient outcome. We aimed to determine the performance of MYC IHC in clinical practice. We reviewed MYC IHC performed on control specimens and 256 aggressive B-cell lymphomas and compared clinically reported IHC scores with experts' review. Control tissues showed less than 5% variation in daily IHC staining. Reported and expert IHC scores were well correlated (r = 0.86) with an SD of 14.2%. Reported IHC scores 30% or less and 70% or more were accurate (94.5%) compared with experts in categorizing tumors as "MYC IHC-Low" and "MYC IHC-High," respectively, but scores 40% to 60% were not (60.3%). The mean IHC score among lymphomas with MYC rearrangements was 80%, but with a large range of scores (20%-100%). There was no statistically significant association between IHC score and MYC copy number. Under optimal conditions, clinically reported MYC IHC scores are concordant with expert scores within 15%. MYC IHC does not capture all B-cell lymphomas with MYC rearrangements, however. MYC IHC and MYC fluorescence in situ hybridization are both recommended to identify MYC-driven B-cell lymphomas. © American Society for Clinical Pathology, 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  1. The Norwegian PMS2 founder mutation c.989-1G > T shows high penetrance of microsatellite instable cancers with normal immunohistochemistry.

    PubMed

    Grindedal, Eli Marie; Aarset, Harald; Bjørnevoll, Inga; Røyset, Elin; Mæhle, Lovise; Stormorken, Astrid; Heramb, Cecilie; Medvik, Heidi; Møller, Pål; Sjursen, Wenche

    2014-01-01

    Using immunohistochemistry (IHC) to select cases for mismatch repair (MMR) genetic testing, we failed to identify a large kindred with the deleterious PMS2 mutation c.989-1G > T. The purpose of the study was to examine the sensitivity of IHC and microsatellite instability-analysis (MSI) to identify carriers of the mutation, and to estimate its penetrance and expressions. All carriers and obligate carriers of the mutation were identified. All cancer diagnoses were confirmed. IHC and MSI-analysis were performed on available tumours. Penetrances of cancers included in the Amsterdam and the Bethesda Criteria, for MSI-high tumours and MSI-high and low tumours were calculated by the Kaplan-Meier algorithm. Probability for co-segregation of the mutation and cancers by chance was 0.000004. Fifty-six carriers or obligate carriers were identified. There was normal staining for PMS2 in 15/18 (83.3%) of tumours included in the AMS1/AMS2/Bethesda criteria. MSI-analysis showed that 15/21 (71.4%) of tumours were MSI-high and 4/21 (19.0%) were MSI-low. Penetrance at 70 years was 30.6% for AMS1 cancers (colorectal cancers), 42.8% for AMS2 cancers, 47.2% for Bethesda cancers, 55.6% for MSI-high and MSI-low cancers and 52.2% for MSI-high cancers. The mutation met class 5 criteria for pathogenicity. IHC was insensitive in detecting tumours caused by the mutation. Penetrance of cancers that displayed MSI was 56% at 70 years. Besides colorectal cancers, the most frequent expressions were carcinoma of the endometrium and breast in females and stomach and prostate in males.

  2. The Norwegian PMS2 founder mutation c.989-1G > T shows high penetrance of microsatellite instable cancers with normal immunohistochemistry

    PubMed Central

    2014-01-01

    Background Using immunohistochemistry (IHC) to select cases for mismatch repair (MMR) genetic testing, we failed to identify a large kindred with the deleterious PMS2 mutation c.989-1G > T. The purpose of the study was to examine the sensitivity of IHC and microsatellite instability-analysis (MSI) to identify carriers of the mutation, and to estimate its penetrance and expressions. Methods All carriers and obligate carriers of the mutation were identified. All cancer diagnoses were confirmed. IHC and MSI-analysis were performed on available tumours. Penetrances of cancers included in the Amsterdam and the Bethesda Criteria, for MSI-high tumours and MSI-high and low tumours were calculated by the Kaplan-Meier algorithm. Results Probability for co-segregation of the mutation and cancers by chance was 0.000004. Fifty-six carriers or obligate carriers were identified. There was normal staining for PMS2 in 15/18 (83.3%) of tumours included in the AMS1/AMS2/Bethesda criteria. MSI-analysis showed that 15/21 (71.4%) of tumours were MSI-high and 4/21 (19.0%) were MSI-low. Penetrance at 70 years was 30.6% for AMS1 cancers (colorectal cancers), 42.8% for AMS2 cancers, 47.2% for Bethesda cancers, 55.6% for MSI-high and MSI-low cancers and 52.2% for MSI-high cancers. Conclusions The mutation met class 5 criteria for pathogenicity. IHC was insensitive in detecting tumours caused by the mutation. Penetrance of cancers that displayed MSI was 56% at 70 years. Besides colorectal cancers, the most frequent expressions were carcinoma of the endometrium and breast in females and stomach and prostate in males. PMID:24790682

  3. Evaluating the Minimal Specimens From Endoscopic Ultrasound-Guided Fine-Needle Aspiration in Pancreatic Masses

    PubMed Central

    Park, Joo Kyung; Kang, Ki Joo; Oh, Cho Rong; Lee, Jong Kyun; Lee, Kyu Taek; Jang, Kee Taek; Park, Sang-Mo; Lee, Kwang Hyuck

    2016-01-01

    Abstract Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) has become one of the most useful diagnostic modalities for the diagnosis of pancreatic mass. The aim of this study was to investigate the role of analyzing the minimal specimens obtained by EUS-FNA for the diagnosis of solid masses of pancreas. This study consisted of retrospective and prospective analyses. The retrospective study was performed on 116 patients who underwent EUS-FNA of solid masses for cytological smear, histological analysis, and combined analysis including immunohistochemical (IHC) staining. In the prospective study, 79 patients were enrolled to evaluate the quality and accuracy of EUS-FNA histological analysis and feasibility of IHC staining. The final diagnoses of all patients included pancreatic cancer (n = 126), nonpancreatic cancer (n = 21), other neoplasm (n = 27), and benign lesions (n = 21). In our retrospective study, the combined analysis was more sensitive than cytological analysis alone (P < 0.01). The overall sensitivity of cytology, histology, and combined analysis was 69.8%, 67.2%, and 81.8%, respectively. In the prospective analysis, 64.2% of all punctures were helpful for determining the diagnosis and 40.7% provided sufficient tissue for IHC staining. Histological analysis was helpful for diagnosis in 74.7% of patients. IHC staining was necessary for a definite diagnosis in 11.4% of patients, especially in the cases of nonmalignant pancreatic mass. Histological analysis and IHC study of EUS-FNA specimens was useful for the accurate diagnosis of pancreatic and peripancreatic lesions. Combined analysis showed significantly higher sensitivity than cytology alone because IHC staining was helpful for a diagnosis in some patients. PMID:27227937

  4. A Microfluidic Immunostaining System Enables Quality Assured and Standardized Immunohistochemical Biomarker Analysis

    NASA Astrophysics Data System (ADS)

    Kwon, Seyong; Cho, Chang Hyun; Kwon, Youngmee; Lee, Eun Sook; Park, Je-Kyun

    2017-04-01

    Immunohistochemistry (IHC) plays an important role in biomarker-driven cancer therapy. Although there has been a high demand for standardized and quality assured IHC, it has rarely been achieved due to the complexity of IHC testing and the subjective validation-based process flow of IHC quality control. We present here a microfluidic immunostaining system for the standardization of IHC by creating a microfluidic linearly graded antibody (Ab)-staining device and a reference cell microarray. Unlike conventional efforts, our system deals primarily with the screening of biomarker staining conditions for quantitative quality assurance testing in IHC. We characterized the microfluidic matching of Ab staining intensity using three HER2 Abs produced by different manufacturers. The quality of HER2 Ab was also validated using tissues of breast cancer patients, demonstrating that our system is an efficient and powerful tool for the standardization and quality assurance of IHC.

  5. [Her2 testing in gastric cancer. What is different in comparison to breast cancer?].

    PubMed

    Rüschoff, J; Nagelmeier, I; Baretton, G; Dietel, M; Höfler, H; Schildhaus, H U; Büttner, R; Schlake, W; Stoss, O; Kreipe, H H

    2010-05-01

    Based on data from a large multicenter phase III trial (ToGA study) trastuzumab has very recently been approved by the EMEA for metastatic gastric cancer and adenocarcinoma of the gastro-esophageal junction. Only patients with tumors which over express Her2 as defined by IHC2+ and a confirmatory FISH+ result, or IHC 3+, determined by an accurate and validated assay are eligible for trastuzumab therapy. However, testing of Her2 status by immunohistochemistry (IHC) differs from breast cancer in core aspects: 1. IHC2+/3+ is scored even though membranous staining is incomplete if membrane staining is clearly detectable even at low magnification (2.5x/5x, 3+) or medium magnification (10x/20x, 2+). 2. Additionally, membrane staining at the appropriate intensity found in at least 10% of tumor cells is restricted to resection specimens. Evaluation of Her2 in situ hybridization (ISH) is similar to breast cancer with ratio values of > or =2.0 indicating Her2 gene amplification. Taking these modifications into account and defining the HER2 positive subgroup as IHC 3+ and IHC2+/FISH+, approximately 16% of gastric cancers are considered Her2 positive, affecting mainly tumor regions with intestinal (gland forming) type carcinoma. In contrast to breast cancer, up to one-third of gastric cancers show a heterogeneous Her2 status both at IHC and ISH levels which favors bright field ISH over FISH.

  6. [Classification of cardiac amyloidosis: an immunohistochemical analysis].

    PubMed

    Li, L; Duan, X J; Sun, Y; Lu, Y; Xu, H Y; Wang, Q Z; Wang, H Y

    2018-02-08

    Objective: To evaluate the sensitivity and specificity of immunohistochemistry (IHC) in the classification of cardiac amyloidosis on endomyocardial biopsy (EMB) and heart allograft. Methods: Twenty cardiac tissues from 19 patients at Fuwai Hospital from January, 1990 to April, 2017 with histopathologic features of amyloidosis and Congo red staining positivity were included. IHC was performed with monoclonal antibodies against AA amyloid and polyclonal antibodies against transthyretin (ATTR), λ-light chain (AL-λ), κ-light chain (AL-κ), ApoAⅠ, ApoAⅡ, ApoA Ⅳ and β(2)-microglobin. The extent of interstitial staining was evaluated by light microscopy, and three patterns were recognized; these included diffuse pericellular pattern, discrete pericellular pattern, and nodular pattern. Two patterns of vascular deposition were also noted, including arterial pattern and venous pattern. Endocardial involvement was also assessed and recorded. Results: Nineteen cases were divided into three groups according to the pattern of proteins expression in specimens. The first group (5 cases) only showed single protein expression on EMB. The second group (6 cases) showed more than one protein expression, but one of them was intensely stained or any staining of any protein together with ApoA Ⅳ co-staining. The third group (8 cases) also showed more than one protein expression and all of them had intense staining. Amyloid deposits were successfully subtyped as AL-λ, ATTR, AL-κ and ApoAⅠby IHC in the former two groups with the sensitivity of 11/19. In the third group, amyloid deposits could not be subtyped by immunohistochemistry due to their poor specificity. The pericellular pattern tended to favor AL over ATTR amyloidosis and vascular deposition tended to favor ATTR. Conclusions: Amyloid deposits can be reliably subtyped in diagnostic cardiac specimens using IHC. The co-deposition of chaperon proteins, the distribution of amyloid proteins and clinical features are also

  7. Cell-based quantification of biomarkers from an ultra-fast microfluidic immunofluorescent staining: application to human breast cancer cell lines

    NASA Astrophysics Data System (ADS)

    Migliozzi, D.; Nguyen, H. T.; Gijs, M. A. M.

    2018-02-01

    Immunohistochemistry (IHC) is one of the main techniques currently used in the clinics for biomarker characterization. It consists in colorimetric labeling with specific antibodies followed by microscopy analysis. The results are then used for diagnosis and therapeutic targeting. Well-known drawbacks of such protocols are their limited accuracy and precision, which prevent the clinicians from having quantitative and robust IHC results. With our work, we combined rapid microfluidic immunofluorescent staining with efficient image-based cell segmentation and signal quantification to increase the robustness of both experimental and analytical protocols. The experimental protocol is very simple and based on fast-fluidic-exchange in a microfluidic chamber created on top of the formalin-fixed-paraffin-embedded (FFPE) slide by clamping it a silicon chip with a polydimethyl siloxane (PDMS) sealing ring. The image-processing protocol is based on enhancement and subsequent thresholding of the local contrast of the obtained fluorescence image. As a case study, given that the human epidermal growth factor receptor 2 (HER2) protein is often used as a biomarker for breast cancer, we applied our method to HER2+ and HER2- cell lines. We report very fast (5 minutes) immunofluorescence staining of both HER2 and cytokeratin (a marker used to define the tumor region) on FFPE slides. The image-processing program can segment cells correctly and give a cell-based quantitative immunofluorescent signal. With this method, we found a reproducible well-defined separation for the HER2-to-cytokeratin ratio for positive and negative control samples.

  8. The minimal carcinoma triple stain is superior to commercially available multiplex immunohistochemical stains: breast triple stain and LC/DC breast cocktail.

    PubMed

    Ginter, Paula S; Varma, Sonal; Liu, Yi-Fang; Shin, Sandra J

    2015-12-01

    The Minimal Carcinoma (MC) Triple Stain is a tri-chromogen multiplex immunostain (CK7, p63, and E-cadherin) helpful in classifying morphologically ambiguous and/or small carcinomas as either ductal or lobular and/or in situ or invasive. We compared the utility of this stain with two commercially available duplex/multiplex immunostains: Breast Triple Stain (BTS) (Clarient, Aliso Viejo, CA; CK5, p63, and CK8/18) and LC/DC Breast Cocktail (LCDC) (Biocare, Concord, CA; E-cadherin and p120). Ninety-seven mammary carcinomas stained with the MC Triple Stain, BTS, and LCDC were compared. The MC Triple Stain, LCDC, and BTS were diagnostic in 90 (93%) of 97, 82 (85%) of 97, and 85 (88%) of 97 of cases, respectively. All stains showed decreased diagnostic utility due to variability in tissue integrity, quality of the staining, and/or ease of interpretation. In cases where all immunostains were interpretable, the MC Triple Stain yielded the most information. When technically sufficient, all three immunostains demonstrated relative strengths and weaknesses in their ability to provide diagnostic information with the highest consistency and ease of use. Many cases stained with LCDC were technically insufficient due to a suboptimal staining protocol provided by the company. Overall, the MC Triple Stain outperformed BTS and LCDC by more consistently providing more diagnostic information. The MC Triple Stain is a viable alternative to other multiplex immunostains in evaluating small foci of carcinoma, particularly when both the histologic type and extent of disease (in situ vs invasive) require clarification. Copyright© by the American Society for Clinical Pathology.

  9. Immunohistochemical null-phenotype for mismatch repair proteins in colonic carcinoma associated with concurrent MLH1 hypermethylation and MSH2 somatic mutations.

    PubMed

    Wang, Tao; Stadler, Zsofia K; Zhang, Liying; Weiser, Martin R; Basturk, Olca; Hechtman, Jaclyn F; Vakiani, Efsevia; Saltz, Lenard B; Klimstra, David S; Shia, Jinru

    2018-04-01

    Microsatellite instability, a well-established driver pathway in colorectal carcinogenesis, can develop in both sporadic and hereditary conditions via different molecular alterations in the DNA mismatch repair (MMR) genes. MMR protein immunohistochemistry (IHC) is currently widely used for the detection of MMR deficiency in solid tumors. The IHC test, however, can show varied staining patterns, posing challenges in the interpretation of the staining results in some cases. Here we report a case of an 80-year-old female with a colonic adenocarcinoma that exhibited an unusual "null" IHC staining pattern with complete loss of all four MMR proteins (MLH1, MSH2, MSH6, and PMS2). This led to subsequent MLH1 methylation testing and next generation sequencing which demonstrated that the loss of all MMR proteins was associated with concurrent promoter hypermethylation of MLH1 and double somatic truncating mutations in MSH2. These molecular findings, in conjunction with the patient's age being 80 years and the fact that the patient had no personal or family cancer history, indicated that the MMR deficiency was highly likely sporadic in nature. Thus, the stringent Lynch syndrome type surveillance programs were not recommended to the patient and her family members. This case illustrates a rare but important scenario where a null IHC phenotype signifies complex underlying molecular alternations that bear clinical management implications, highlighting the need for recognition and awareness of such unusual IHC staining patterns.

  10. "Atypical" chronic wasting disease in PRNP genotype 225FF mule deer.

    PubMed

    Wolfe, Lisa L; Fox, Karen A; Miller, Michael W

    2014-07-01

    We compared mule deer (Odocoileus hemionus) of two different PRNP genotypes (225SS, 225FF) for susceptibility to chronic wasting disease (CWD) in the face of environmental exposure to infectivity. All three 225SS deer had immunohistochemistry (IHC)-positive tonsil biopsies by 710 days postexposure (dpe), developed classic clinical signs by 723-1,200 dpe, and showed gross and microscopic pathology, enzyme-linked immunosorbent assay (ELISA) results, and IHC staining typical of prion disease in mule deer. In contrast, although all three 225FF deer also became infected, the two individuals surviving >720 dpe had consistently negative biopsies, developed more-subtle clinical signs of CWD, and died 924 or 1,783 dpe. The 225FF deer were "suspect" by ELISA postmortem but showed negative or equivocal IHC staining of lymphoid tissues; both clinically affected 225FF deer had spongiform encephalopathy in the absence of IHC staining in the brain tissue. The experimental cases resembled three cases encountered among five additional captive 225FF deer that were not part of our experiment but also died from CWD. Aside from differences in clinical disease presentation and detection, 225FF mule deer also showed other, more-subtle, atypical traits that may help to explain the rarity of this genotype in natural populations, even in the presence of enzootic CWD.

  11. Diagnostic utility of NCOA2 fluorescence in situ hybridization and Stat6 immunohistochemistry staining for soft tissue angiofibroma and morphologically similar fibrovascular tumors.

    PubMed

    Sugita, Shintaro; Aoyama, Tomoyuki; Kondo, Kei; Keira, Yoshiko; Ogino, Jiro; Nakanishi, Katsuya; Kaya, Mitsunori; Emori, Makoto; Tsukahara, Tomohide; Nakajima, Hisaya; Takagi, Masayuki; Hasegawa, Tadashi

    2014-08-01

    Soft tissue angiofibroma (STA), a recently suggested new histologic entity, is a benign fibrovascular soft tissue tumor composed of bland spindle-shaped tumor cells with abundant collagenous to myxoid stroma and branching small vessels. The lesion has a characteristic AHRR-NCOA2 fusion gene derived from chromosomal translocation of t(5;8)(p15;q13). However, morphologically similar tumors containing abundant fibrovascular and myxoid stroma can complicate diagnosis. We designed an original DNA probe for detecting NCOA2 split signals on fluorescence in situ hybridization (FISH) and estimated its utility with 20 fibrovascular tumors: 4 each of STAs, solitary fibrous tumors (SFTs), and cellular angiofibromas and 3 each of low-grade myxofibrosarcomas, myxoid liposarcomas, and low-grade fibromyxoid sarcomas. We also performed FISH for 13q14 deletion and immunohistochemistry (IHC) staining for estrogen receptor, progesterone receptor, retinoblastoma protein, and MUC-4 expression. Furthermore, IHC for Stat6 was conducted in the 20 cases analyzed by FISH and in an additional 26 SFTs. We found moderate to strong nuclear Stat6 expression in all SFTs but no expression in the other tumors. Both estrogen receptor and progesterone receptor expressions were observed in STAs, SFTs, and cellular angiofibromas. Expression of retinoblastoma protein was found in less than 10% of cells in all tumor types except myxoid liposarcoma. The low-grade fibromyxoid sarcomas were strongly positive for MUC-4. All STAs showed NCOA2 split signals on FISH. All tumors, regardless of histologic type, had 13q14 deletion. The NCOA2 FISH technique is a practical method for confirming STA diagnosis. The combination of NCOA2 FISH and Stat6 IHC proved effective for the differential diagnosis of STA, even when using small biopsy specimens. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. A comparative study of quantitative immunohistochemistry and quantum dot immunohistochemistry for mutation carrier identification in Lynch syndrome.

    PubMed

    Barrow, Emma; Evans, D Gareth; McMahon, Ray; Hill, James; Byers, Richard

    2011-03-01

    Lynch Syndrome is caused by mutations in DNA mismatch repair (MMR) genes. Mutation carrier identification is facilitated by immunohistochemical detection of the MMR proteins MHL1 and MSH2 in tumour tissue and is desirable as colonoscopic screening reduces mortality. However, protein detection by conventional immunohistochemistry (IHC) is subjective, and quantitative techniques are required. Quantum dots (QDs) are novel fluorescent labels that enable quantitative multiplex staining. This study compared their use with quantitative 3,3'-diaminobenzidine (DAB) IHC for the diagnosis of Lynch Syndrome. Tumour sections from 36 mutation carriers and six controls were obtained. These were stained with DAB on an automated platform using antibodies against MLH1 and MSH2. Multiplex QD immunofluorescent staining of the sections was performed using antibodies against MLH1, MSH2 and smooth muscle actin (SMA). Multispectral analysis of the slides was performed. The staining intensity of DAB and QDs was measured in multiple colonic crypts, and the mean intensity scores calculated. Receiver operating characteristic (ROC) curves of staining performance for the identification of mutation carriers were evaluated. For quantitative DAB IHC, the area under the MLH1 ROC curve was 0.872 (95% CI 0.763 to 0.981), and the area under the MSH2 ROC curve was 0.832 (95% CI 0.704 to 0.960). For quantitative QD IHC, the area under the MLH1 ROC curve was 0.812 (95% CI 0.681 to 0.943), and the area under the MSH2 ROC curve was 0.598 (95% CI 0.418 to 0.777). Despite the advantage of QD staining to enable several markers to be measured simultaneously, it is of lower utility than DAB IHC for the identification of MMR mutation carriers. Automated DAB IHC staining and quantitative slide analysis may enable high-throughput IHC.

  13. Review of Current Applications of Immunohistochemistry in Pediatric Nonneoplastic Gastrointestinal, Hepatobiliary, and Pancreatic Lesions

    PubMed Central

    de Nanassy, Joseph; El Demellawy, Dina

    2017-01-01

    Immunohistochemical (IHC) stains are widely used by pathologists for a variety of considerations in the diagnostic workup of pediatric nonneoplastic lesions in gastrointestinal (GI), hepatic, biliary, and pancreatic lesions. The pathologic changes cover a wide range and types of presentations, including inflammatory (bacterial and viral), metaplastic, posttransplant lymphoproliferative, autoimmune, metabolic, degenerative, developmental, and genetic conditions, among others. The everyday practical value of IHC stains covers primary identification, confirmation, differential, and/or exclusionary roles in the hands and eyes and minds of the practitioners. This article is intended to review and discuss the currently available IHC stains for a variety of pediatric GI, hepatobiliary, and pancreatic lesions as encountered in the day-to-day practice of pathologists and clinicians. It reflects the most recent methods and types of IHC stains with the stated aim of helping to provide a quick reference for diagnostic considerations and thereby facilitate the workup of a broad range of GI and related conditions in a pediatric population. The tables provide a handy reference on a wide range of IHC stains for commonly encountered lesions covering a variety of pediatric GI, hepatobiliary, and pancreatic conditions that are amenable to light microscopic diagnostic interpretation. PMID:28469406

  14. Exogenous bFGF or TGFβ1 accelerates healing of reconstructed dura by CO2 laser soldering in minipigs.

    PubMed

    Wang, Zhenmin; Zhong, Hongliang; Yang, Zhijun; Zhao, Fu; Wang, Bo; Qu, Peiran; Liu, Pinan

    2014-05-01

    This study aims to explore the probable mechanism of better result of dural reconstruction by CO2 laser soldering and the effect of exogenous basic fibroblast growth factor (bFGF) or transforming growth factor-beta1(TGFβ1) on wound healing. In part I of the study, ten minipigs were randomized into two equal groups, and the dural defects were reconstructed by conventional fibrin glue (FG) bonding (group I a) or by CO2 laser soldering (group Ib). In part II, 36 minipigs were randomized into three equal groups, and the dural defect was reconstructed by CO2 laser soldering; then exogenous bFGF or TGFβ1 was administered in group IIb and group IIc, respectively, while group IIa served as control group. The dural specimens were harvested at 1st week postoperatively in part I; and at 1st, 2nd, 3rd, and 4th week postoperatively in part II, they were examined for healing condition and subjected to hematoxylin-eosin (HE) staining and immunohistochemical (IHC) staining with antibodies against bFGF and TGFβ1. In part I, group Ib showed higher fibroblast cell density than group Ia (P < 0.05). The optical density (OD) for IHC staining with antibodies against bFGF of group Ib was significantly higher than that of group Ia (P < 0.05), and for IHC staining with antibodies against TGFβ1, group Ib showed positive staining while group Ia was negative. In part II, administering exogenous bFGF or TGFβ1 made a left shift of fibroblast cell number-time curve compared with control group. For specimens' IHC staining with antibodies against bFGF, the OD of group IIb was higher than that of group IIa in the corresponding time. For specimens' IHC staining with antibodies against TGFβ1, the OD of groups IIb and IIc was both higher than that of group IIa (P < 0.05 and P < 0.01, respectively). In conclusion, CO2 laser may trigger fibroblast proliferation through stimulating the secretion of bFGF and TGFβ1. Topically administering exogenous bFGF or TGFβ1 could accelerate the healing of the

  15. Differential staining of bacteria: gram stain.

    PubMed

    Moyes, Rita B; Reynolds, Jackie; Breakwell, Donald P

    2009-11-01

    In 1884, Hans Christian Gram, a Danish doctor, developed a differential staining technique that is still the cornerstone of bacterial identification and taxonomic division. This multistep, sequential staining protocol separates bacteria into four groups based on cell morphology and cell wall structure: Gram-positive cocci, Gram-negative cocci, Gram-positive rods, and Gram-negative rods. The Gram stain is useful for assessing bacterial contamination of tissue culture samples or for examining the Gram stain status and morphological features of bacteria isolated from mixed or isolated bacterial cultures. (c) 2009 by John Wiley & Sons, Inc.

  16. Alternative to xylene as a clearing agent in histopathology

    PubMed Central

    Alwahaibi, Nasar; Aljaradi, Shaima; Alazri, Horiyah

    2018-01-01

    INTRODUCTION: Clearing is an essential step in processing tissue for light microscopy. Xylene is the clearing agent used most commonly worldwide. Xylene is toxic and therefore a threat to personnel working in histopathology laboratories. We evaluated a safer alternative clearing agent for use in the histopathology laboratory. MATERIALS AND METHODS: We used 230 formalin-fixed, paraffin-embedded tissue blocks from 19 different tissues. Half of the specimens were processed using xylene and half were processed using UltraClear™. Tissues were evaluated for eight parameters: sectioning, nuclear staining, cytoplasmic staining, overall cell morphology, clarity of staining, uniformity of staining, quality of immunohistochemistry (IHC), and cost. RESULTS: Both UltraClear™ and xylene processed sections scored 100% for IHC. Sections processed using UltraClear™ were easy to cut (81.7%) as were xylene processed sections (96.5%). UltraClear™ processed sections showed 67%, 60.9%, 52.2%, 63.5%, and 67% for nuclear staining, cytoplasmic staining, cell morphology, clarity of staining, and uniformity of staining, respectively. UltraClear™ is twice as expensive as xylene. We found that tissues processed using UltraClear™ were easy to cut and worked well for both hematoxylin and eosin and IHC staining. CONCLUSION: UltraClear™ is less toxic, less flammable, friendlier to the environment, and easy to handle, but it is two times expensive than xylene. The findings of this study recommend the use of UltraClear™ solution as a routine clearing agent in histopathology laboratories. However, further studies are required. PMID:29692586

  17. Screening for ROS1 gene rearrangements in non-small cell lung cancers using immunohistochemistry with FISH confirmation is an effective method to identify this rare target

    PubMed Central

    Selinger, Christina I; Li, Bob T; Pavlakis, Nick; Links, Matthew; Gill, Anthony J; Lee, Adrian; Clarke, Stephen; Tran, Thang N; Lum, Trina; Yip, Po Yee; Horvath, Lisa; Yu, Bing; Kohonen-Corish, Maija RJ; O’Toole, Sandra A; Cooper, Wendy A

    2016-01-01

    Aims To assess the prevalence of ROS1 rearrangements in a retrospective and prospective diagnostic Australian cohort and evaluate the effectiveness of immunohistochemical screening. Methods A retrospective cohort of 278 early stage lung adenocarcinomas and an additional 104 prospective NSCLC cases referred for routine molecular testing were evaluated. ROS1 immunohistochemistry (IHC) was performed (D4D6 clone, Cell Signaling Technology) on all cases as well as fluorescence in situ hybridisation (FISH) using the ZytoVision and Abbott Molecular ROS1 FISH probes, with ≥15% of cells with split signals considered positive for rearrangement. Results Eighty eight cases (32%) from the retrospective cohort showed staining by ROS1 IHC, and one case (0.4%) showed ROS1 rearrangement by FISH. Nineteen of the prospective diagnostic cases showed ROS1 IHC staining of which 12 (12%) cases were confirmed as ROS1 rearranged by FISH. There were no ROS1 rearranged cases that showed no expression of ROS1 with IHC. The ROS1 rearranged cases in the prospective cohort were all EGFR wildtype and ALK rearrangement negative. The sensitivity of ROS1 IHC in the retrospective cohort was 100% and specificity was 76%. Conclusions ROS1 rearrangements are rare events in lung adenocarcinomas. Selection of cases for ROS1 FISH testing, by excluding EGFR/ALK positive cases and use of IHC to screen for potentially positive cases can be used to enrich for the likelihood of a identifying a ROS1 rearranged lung cancer and prevent the need to undertake expensive and time consuming FISH testing in all cases. PMID:27599111

  18. Variability in Platelet-Derived Growth Factor Receptor Alpha Antibody Specificity May Impact Clinical Utility of Immunohistochemistry Assays

    PubMed Central

    Holzer, Timothy R.; O’Neill Reising, Leslie; Credille, Kelly M.; Schade, Andrew E.; Oakley, Gerard J.

    2016-01-01

    Aberrant regulation of the receptor tyrosine kinase platelet-derived growth factor alpha (PDGFRα) is implicated in several types of cancer. Inhibition of the PDGFRα pathway may be a beneficial therapy, and detection of PDGFRα in tumor biopsies may lead to insights about which patients respond to therapy. Exploratory or clinical biomarker use of PDGFRα IHC has been frequently reported, often with polyclonal antibody sc-338. An sc-338-based assay was systematically compared with anti-PDGFRα rabbit monoclonal antibody D13C6 using immunoblot profiling and IHC in formalin-fixed and paraffin-embedded human tumor cell lines. Application of sc-338 to blots of whole cell lysates showed multiple bands including some of unknown origin, whereas application of D13C6 resulted in a prominent band at the expected molecular mass of PDGFRα. The IHC assay using D13C6 showed appropriate staining in cell lines, whereas the assay using sc-338 suggested nonspecific detection of proteins. An optimized IHC assay using D13C6 showed a range of staining in the tumor stromal compartment in lung and ovarian carcinomas. These observations suggest that use of clone sc-338 produced unreliable results and should not be used for an IHC research grade assay. In addition, this precludes its use as a potential antibody for a clinical diagnostic tool. PMID:27837159

  19. Immunohistochemical Identification and Pathologic Findings in Natural Cases of Equine Abortion Caused by Leptospiral Infection

    PubMed Central

    Szeredi, L.; Haake, D. A.

    2009-01-01

    The aim of this study was to examine the utility of immunohistochemistry (IHC) in the diagnosis of leptospiral equine abortion and to compare IHC to silver staining and serology of the aborted mares. Ninety-six fetuses from 57 farms were examined using all 3 diagnostic techniques, revealing evidence of leptospiral infection in 3 fetuses (3.1%) from 3 (5.3%) different farms. A new finding in 1 of these confirmed cases of leptospiral abortion was the presence of macroscopic pinpoint grayish-white nodules that had a histologic correlate of hepatic necrosis; other histologic findings were consistent with those previously reported. IHC performed using 2 different leptospiral antisera (multivalent whole-cell rabbit antiserum and rabbit antiserum against the major outer membrane protein LipL32) yielded similar results. IHC was more sensitive (19/21 [90.5%] tissue samples) than silver staining (8/21 [38.1%] tissue samples), and more specific than serology performed using the microscopic agglutination test. The primary advantage of IHC over silver staining was the ability of IHC to identify leptospiral antigen not only as morphologically intact spiral forms. PMID:16966455

  20. Positive nuclear BAP1 immunostaining helps differentiate non-small cell lung carcinomas from malignant mesothelioma

    PubMed Central

    Carbone, Michele; Shimizu, David; Napolitano, Andrea; Tanji, Mika; Pass, Harvey I.; Yang, Haining; Pastorino, Sandra

    2016-01-01

    The differential diagnosis between pleural malignant mesothelioma (MM) and lung cancer is often challenging. Immunohistochemical (IHC) stains used to distinguish these malignancies include markers that are most often positive in MM and less frequently positive in carcinomas, and vice versa. However, in about 10–20% of the cases, the IHC results can be confusing and inconclusive, and novel markers are sought to increase the diagnostic accuracy. We stained 45 non-small cell lung cancer samples (32 adenocarcinomas and 13 squamous cell carcinomas) with a monoclonal antibody for BRCA1-associated protein 1 (BAP1) and also with an IHC panel we routinely use to help differentiate MM from carcinomas, which include, calretinin, Wilms Tumor 1, cytokeratin 5, podoplanin D2-40, pankeratin CAM5.2, thyroid transcription factor 1, Napsin-A, and p63. Nuclear BAP1 expression was also analyzed in 35 MM biopsies. All 45 non-small cell lung cancer biopsies stained positive for nuclear BAP1, whereas 22/35 (63%) MM biopsies lacked nuclear BAP1 staining, consistent with previous data. Lack of BAP1 nuclear staining was associated with MM (two-tailed Fisher's Exact Test, P = 5.4 × 10−11). Focal BAP1 staining was observed in a subset of samples, suggesting polyclonality. Diagnostic accuracy of other classical IHC markers was in agreement with previous studies. Our study indicated that absence of nuclear BAP1 stain helps differentiate MM from lung carcinomas. We suggest that BAP1 staining should be added to the IHC panel that is currently used to distinguish these malignancies. PMID:27447750

  1. Correlation between viral loads of cytomegalovirus in blood and bronchoalveolar lavage specimens from lung transplant recipients determined by histology and immunohistochemistry.

    PubMed

    Chemaly, Roy F; Yen-Lieberman, Belinda; Castilla, Elias A; Reilly, Amy; Arrigain, Susana; Farver, Carol; Avery, Robin K; Gordon, Steven M; Procop, Gary W

    2004-05-01

    Cytomegalovirus (CMV) is an important pathogen in lung transplant recipients. Early detection of CMV end-organ disease should help with treatment management. We determined the CMV viral load by hybrid capture in bronchoalveolar lavage (BAL) fluid samples from patients who had undergone lung transplantation. For 39 of these samples (from 25 patients), corresponding transbronchial biopsy samples were available for CMV immunohistochemistry (IHC). The CMV IHC results were interpreted and categorized as positive or negative, and the positive results were subcategorized as typical if cells with both significant nuclear enlargement or Cowdry A-type inclusions and positive staining were present or as atypical if definitive nuclear staining was seen but significant nuclear enlargement was not. Diagnostic CMV viral inclusions were reported in the anatomic diagnosis, based on hematoxylin-eosin staining alone, for three (8%) of the biopsy samples. CMV was detected by IHC in 13 (33%) samples (5 typical, 8 atypical). The median CMV viral load in BAL samples was 0 copies/ml for BAL samples from patients with IHC-negative biopsy samples; 47,678 copies/ml for BAL samples from patients with biopsy samples with positive, atypical staining; and 1,548,827 copies/ml for BAL samples from patients with biopsy samples with positive, typical staining (P < 0.001). Compared to routine pathology of biopsy samples, the use of IHC increased the diagnostic yield of CMV. Also, the CMV viral load in BAL fluid samples increased along with immunoreactivity from negative to positive, atypical staining to positive, typical staining. The CMV viral load determined with the end-organ sample, the BAL fluid sample, was higher than the corresponding viral load determined with blood. Both IHC and determination of the CMV viral load in BAL samples may be useful for the detection of individuals at risk for the development of fulminant invasive CMV disease.

  2. Gram staining with an automatic machine.

    PubMed

    Felek, S; Arslan, A

    1999-01-01

    This study was undertaken to develop a new Gram-staining machine controlled by a micro-controller and to investigate the quality of slides that were stained in the machine. The machine was designed and produced by the authors. It uses standard 220 V AC. Staining, washing, and drying periods are controlled by a timer built in the micro-controller. A software was made that contains a certain algorithm and time intervals for the staining mode. One-hundred and forty smears were prepared from Escherichia coli, Staphylococcus aureus, Neisseria sp., blood culture, trypticase soy broth, direct pus and sputum smears for comparison studies. Half of the slides in each group were stained with the machine, the other half by hand and then examined by four different microbiologists. Machine-stained slides had a higher clarity and less debris than the hand-stained slides (p < 0.05). In hand-stained slides, some Gram-positive organisms showed poor Gram-positive staining features (p < 0.05). In conclusion, we suggest that Gram staining with the automatic machine increases the staining quality and helps to decrease the work load in a busy diagnostic laboratory.

  3. Screening for ROS1 gene rearrangements in non-small-cell lung cancers using immunohistochemistry with FISH confirmation is an effective method to identify this rare target.

    PubMed

    Selinger, Christina I; Li, Bob T; Pavlakis, Nick; Links, Matthew; Gill, Anthony J; Lee, Adrian; Clarke, Stephen; Tran, Thang N; Lum, Trina; Yip, Po Y; Horvath, Lisa; Yu, Bing; Kohonen-Corish, Maija R J; O'Toole, Sandra A; Cooper, Wendy A

    2017-02-01

    To assess the prevalence of ROS1 rearrangements in a retrospective and prospective diagnostic Australian cohort and evaluate the effectiveness of immunohistochemical screening. A retrospective cohort of 278 early stage lung adenocarcinomas and an additional 104 prospective non-small-cell lung cancer (NSCLC) cases referred for routine molecular testing were evaluated. ROS1 immunohistochemistry (IHC) was performed (D4D6 clone, Cell Signaling Technology) on all cases as well as fluorescence in-situ hybridization (FISH) using the ZytoVision and Abbott Molecular ROS1 FISH probes, with ≥15% of cells with split signals considered positive for rearrangement. Eighty-eight cases (32%) from the retrospective cohort showed staining by ROS1 IHC, and one case (0.4%) showed ROS1 rearrangement by FISH. Nineteen of the prospective diagnostic cases showed ROS1 IHC staining, 12 (12%) cases of which were confirmed as ROS1 rearranged by FISH. There were no ROS1 rearranged cases that showed no expression of ROS1 with IHC. The ROS1 rearranged cases in the prospective cohort were all EGFR wild-type and anaplastic lymphoma kinase (ALK) rearrangement-negative. The sensitivity of ROS1 IHC in the retrospective cohort was 100% and specificity was 76%. ROS1 rearrangements are rare events in lung adenocarcinomas. Selection of cases for ROS1 FISH testing, by excluding EGFR/ALK-positive cases and use of IHC to screen for potentially positive cases, can be used to enrich for the likelihood of identifying a ROS1 rearranged lung cancer and prevent the need to undertake expensive and time-consuming FISH testing in all cases. © 2016 John Wiley & Sons Ltd.

  4. Correlation of immunohistochemical mismatch repair protein status between colorectal carcinoma endoscopic biopsy and resection specimens.

    PubMed

    O'Brien, Odharnaith; Ryan, Éanna; Creavin, Ben; Kelly, Michael E; Mohan, Helen M; Geraghty, Robert; Winter, Des C; Sheahan, Kieran

    2018-02-01

    Microsatellite instability is reflective of a deficient mismatch repair system (dMMR), which may be due to either sporadic or germline mutations in the relevant mismatch repair (MMR) gene. MMR status is frequently determined by immunohistochemistry (IHC) for mismatch repair proteins (MMRPs) on colorectal cancer (CRC) resection specimens. However, IHC testing performed on endoscopic biopsy may be as reliable as that performed on surgical resections. We aimed to evaluate the reliability of MMR IHC staining on preoperative CRC endoscopic biopsies compared with matched-surgical resection specimens. A retrospective search of our institution's histopathology electronic database was performed. Patients with CRC who had MMR IHC performed on both their preoperative endoscopic biopsy and subsequent resection from January 2010 to January 2016 were included. Concordance of MMR staining between biopsy and resection specimens was assessed. From 2000 to 2016, 53 patients had MMR IHC performed on both their preoperative colorectal endoscopic biopsy and resection specimens; 10 patients (18.87%) demonstrated loss of ≥1 MMRP on their initial endoscopic tumour biopsy. The remainder (81.13%) showed preservation of staining for all MMRPs. There was complete agreement in MMR IHC status between the preoperative endoscopic biopsies and corresponding resection specimens in all cases (κ=1.000, P<0.000) with a sensitivity of 100% (95% CI 69.15 to 100) and specificity of 100% (95% CI 91.78 to 100) for detection of dMMR. Endoscopic biopsies are a suitable source of tissue for MMR IHC analysis. This may provide a number of advantages to both patients and clinicians in the management of CRC. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  5. Lectin Staining Shows no Evidence of Involvement of Glycocalyx/Mucous Layer Carbohydrate Structures in Development of Celiac Disease

    PubMed Central

    Toft-Hansen, Henrik; Nielsen, Christian; Biagini, Matteo; Husby, Steffen; Lillevang, Søren T.

    2013-01-01

    The presence of unique carbohydrate structures in the glycocalyx/mucous layer of the intestine may be involved in a susceptibility to celiac disease (CD) by serving as attachment sites for bacteria. This host-microbiota interaction may influence the development of CD and possibly other diseases with autoimmune components. We examined duodenal biopsies from a total of 30 children, of which 10 had both celiac disease (CD) and type 1 diabetes (T1D); 10 had CD alone; and 10 were suspected of having gastrointestinal disease, but had normal duodenal histology (non-CD controls). Patients with both CD and T1D were examined before and after remission following a gluten-free diet. We performed lectin histochemistry using peanut agglutinin (PNA) and Ulex europaeus agglutinin (UEA) staining for Gal-β(1,3)-GalNAc and Fucα1-2Gal-R, respectively, of the glycocalyx/mucous layer. The staining was scored based on dissemination of stained structures on a scale from 0 to 3. Evaluation of the scores revealed no difference between biopsies obtained before and after remission in the group of children with both CD and T1D. A comparison of this pre-remission group with the children who had CD alone or the non-CD controls also showed no significant differences. Based on our material, we found no indication that the presence of Gal-β(1,3)-GalNAc or Fucα1-2Gal-R is involved in the susceptibility to CD, or that the disease process affects the expression of these carbohydrates. PMID:24253051

  6. Bulbar conjunctival fluorescein staining in hydrogel contact lens wearers.

    PubMed

    Lakkis, C; Brennan, N A

    1996-07-01

    To evaluate the clinical usefulness of bulbar conjunctival staining in assessing hydrogel contact lens patients. Overall staining, as well as staining at five separate sites (limbal, nasal band, temporal band, superior, and inferior) was graded on an analog scale in 48 contact lens wearing subjects and 50 controls. The degree to which subjects experienced sensations of dryness, wateriness, itchiness, grittiness, and comfort was also assessed using analog scales. Some measure of conjunctival staining was noted in 98% of subjects, with contact lens wearers showing statistically significant greater staining than controls. Only 12% of controls showed staining of greater than grade 1 (equivalent), whereas 62% of contact lens wearers were above this level. Regression analysis showed that overall staining was a function of whether contact lenses were worn, the degree of dryness, and the amount of itchiness. Conjunctival fluorescein staining appears to serve some clinical usefulness as a composite indicator for certain factors and symptoms and, in addition, provides information which is unique for each individual.

  7. Utility of p57 immunohistochemistry in differentiating between complete mole, partial mole & non-molar or hydropic abortus.

    PubMed

    Samadder, Abhimanyu; Kar, Rakhee

    2017-01-01

    There is considerable inter-observer variability in the diagnosis of molar pregnancies by histomorphological examination of products of conception (POC). The p57KIP2 gene is paternally imprinted and expressed from the maternal allele. On immunohistochemistry (IHC) with p57, complete mole (CM) shows absent staining whereas hydropic abortus (HA) and partial mole (PM) show positive staining. This study was undertaken to evaluate the role of p57 IHC along with histomorphology in differentiating between CM, PM and non-molar or HA. This was a cross-sectional study over a period of three and a half years on archival material. Detailed histomorphological review along with p57 IHC was carried out in 28 diagnosed cases (23 CM, 4 PM and 1 molar pregnancy not categorized) and 25 controls of four normal placentas and 21 POC (8 non-hydropic and 13 HA). In 14.8 per cent (4/27) cases, there was discordance in accurate subtyping of molar pregnancy. One case of CM showed inconsistent IHC pattern. In 15.4 per cent (2/13) HA, molar pregnancy was final diagnosis. After final review, there were 25 CM, five PM, 22 non-molar controls including 10 HA and one not assigned (PM/HA). IHC with p57 was negative in 96 per cent CM and positive in 100 and 95 per cent PM and non-molar controls, respectively. This study showed that negative p57KIP2 immunostaining reliably identified CM and could be used in association with the histological findings to distinguish CM from its mimics.

  8. Next-generation sequencing facilitates detection of the classic E13-A20 EML4-ALK fusion in an ALK-FISH/IHC inconclusive biopsy of a stage IV lung cancer patient: a case report.

    PubMed

    Volckmar, Anna-Lena; Endris, Volker; Bozorgmehr, Farastuk; Lier, Clemens; Porcel, Carlota; Kirchner, Martina; Leichsenring, Jonas; Penzel, Roland; Thomas, Michael; Schirmacher, Peter; Warth, Arne; Stenzinger, Albrecht

    2016-11-18

    Inhibition of the oncogenic fusion-gene EML4-ALK is a current first-line approach for patients with stage IV non-small cell lung cancer. While FISH was established as the gold standard for identifying these patients, there is accumulating evidence that other methods of detection, i.e., immunohistochemistry and next-generation sequencing (NGS), exist that may be equally successful. However, the concordance of these methods is under investigation. Adding to the current literature, we here report a 56 year old female never-smoker with stage IV lung adenocarcinoma whose biopsy was IHC and FISH inconclusive but positive in NGS. Retroactive profiling of the resection specimen corroborated fusion reads obtained by NGS, FISH-positivity and showed weak ALK-positivity by IHC. Consequently, we diagnosed the case as ALK-positive rendering the patient eligible to crizotinib treatment. With IHC on biopsy material only, this case would have been overlooked withholding effective therapy.

  9. Putting vital stains in context.

    PubMed

    Efron, Nathan

    2013-07-01

    While vital staining remains a cornerstone in the diagnosis of ocular disease and contact lens complications, there are many misconceptions regarding the properties of commonly used dyes by eye-care practitioners and what is and what is not corneal staining after instillation of sodium fluorescein. Similarly, the proper use and diagnostic utility of rose Bengal and lissamine green B, the other two ophthalmic dyes commonly used for assessing ocular complications, have similarly remained unclear. Due to the limitations of vital stains for definitive diagnosis, concomitant signs and symptoms in addition to a complete patient history are required. Over the past decade, there have been many reports of a type of corneal staining--often referred to as solution-induced corneal staining (SICS)--that is observed with the use of multipurpose solutions in combination with soft lenses, more specifically silicone hydrogel lenses. Some authors believe that SICS is a sign of lens/solution incompatibility; however, new research shows that SICS may be neither a measure of lens/solution biocompatibility nor 'true' corneal staining, as that observed in pathological situations. A large component of SICS may be a benign phenomenon, known as preservative-associated transient hyperfluorescence (PATH). There is a lack of correlated signs and/or symptoms with SICS/PATH. Several properties of SICS/PATH, such as appearance and duration, differentiate it from pathological corneal staining. This paper reviews the properties of vital stains, their use and limitations in assessment of the ocular surface, the aetiology of corneal staining, characteristics of SICS/PATH that differentiate it from pathological corneal staining and what the SICS/PATH phenomenon means for contact lens-wearing patients. © 2012 The Author. Clinical and Experimental Optometry © 2012 Optometrists Association Australia.

  10. Detection of EML4-ALK in Lung Adenocarcinoma Using Pleural Effusion with FISH, IHC, and RT-PCR Methods

    PubMed Central

    Zhou, Xiaodie; Song, Yong; Zhou, Xiaojun; Yu, Like; Wang, Jiandong

    2015-01-01

    Anaplastic lymphoma kinase (ALK) and echinoderm microtubule-associated protein-like 4 (EML4) gene rearrangements occur in approximately 5% of non-small-cell lung cancers (NSCLC), leading to the overexpression of anaplastic lymphoma kinase and predicting a response to the targeted inhibitor, crizotinib. Malignant pleural effusion occurs in most patients with advanced lung cancer, especially adenocarcinoma, and tissue samples are not always available from these patients. We attempted to clarify the feasibility of detecting the EML4-ALK fusion gene in pleural effusion cells using different methods. We obtained 66 samples of pleural effusion from NSCLC patients. The pleural effusion fluid was centrifuged, and the cellular components obtained were formalin fixed and paraffin embedded. The EML4-ALK fusion gene status was determined with fluorescent in situ hybridization (FISH), reverse transcription—polymerase chain reaction (RT-PCR), and immunohistochemistry (IHC). EML4-ALK was detected in three of 66 patient samples (4.5%) with RT-PCR. When the RT-PCR data were used as the standard, one false positive and one false negative samples were identified with IHC; and one false negative sample was identified with FISH. These results suggest that a block of pleural effusion cells can be used to detect the EML4-ALK fusion gene. IHC had good sensitivity, but low specificity. FISH had low sensitivity, but high specificity. RT-PCR is a good candidate method for detecting EML4-ALK in blocks of pleural effusion cells from lung cancer patients. PMID:25785456

  11. Detection of EML4-ALK in lung adenocarcinoma using pleural effusion with FISH, IHC, and RT-PCR methods.

    PubMed

    Liu, Leilei; Zhan, Ping; Zhou, Xiaodie; Song, Yong; Zhou, Xiaojun; Yu, Like; Wang, Jiandong

    2015-01-01

    Anaplastic lymphoma kinase (ALK) and echinoderm microtubule-associated protein-like 4 (EML4) gene rearrangements occur in approximately 5% of non-small-cell lung cancers (NSCLC), leading to the overexpression of anaplastic lymphoma kinase and predicting a response to the targeted inhibitor, crizotinib. Malignant pleural effusion occurs in most patients with advanced lung cancer, especially adenocarcinoma, and tissue samples are not always available from these patients. We attempted to clarify the feasibility of detecting the EML4-ALK fusion gene in pleural effusion cells using different methods. We obtained 66 samples of pleural effusion from NSCLC patients. The pleural effusion fluid was centrifuged, and the cellular components obtained were formalin fixed and paraffin embedded. The EML4-ALK fusion gene status was determined with fluorescent in situ hybridization (FISH), reverse transcription-polymerase chain reaction (RT-PCR), and immunohistochemistry (IHC). EML4-ALK was detected in three of 66 patient samples (4.5%) with RT-PCR. When the RT-PCR data were used as the standard, one false positive and one false negative samples were identified with IHC; and one false negative sample was identified with FISH. These results suggest that a block of pleural effusion cells can be used to detect the EML4-ALK fusion gene. IHC had good sensitivity, but low specificity. FISH had low sensitivity, but high specificity. RT-PCR is a good candidate method for detecting EML4-ALK in blocks of pleural effusion cells from lung cancer patients.

  12. Why and how immunohistochemistry should now be used to screen for the BRAFV600E status in metastatic melanoma? The experience of a single institution (LCEP, Nice, France).

    PubMed

    Long, E; Ilie, M; Lassalle, S; Butori, C; Poissonnet, G; Washetine, K; Mouroux, J; Lespinet, V; Lacour, J P; Taly, V; Laurent-Puig, P; Bahadoran, P; Hofman, V; Hofman, P

    2015-12-01

    Knowledge of the BRAFV600E status is mandatory in metastatic melanoma patients (MMP). Molecular biology is currently the gold standard method for status assessment. We assessed and compared the specificity, sensibility, cost-effectiveness and turnaround time (TAT) of immunohistochemistry (IHC) and molecular biology for detection of the BRAFV600E mutation in 188 MMP. IHC, with the VE1 antibody, and pyrosequencing analysis were performed with formalin fixed paraffin embedded tumour samples. The BRAFV600E mutation was detected by pyrosequencing in 91/188 (48%) patients. IHC was strongly positive (3+) in all of these 91 cases. IHC was strongly positive in 9/188 (5%) cases in which the molecular testing failed due to non-amplifiable DNA. Weak or moderate staining was noted in 10/188 (5%) cases in which the molecular biology identified BRAF wild-type tumours. The ratio of the global cost for IHC/molecular biology testing was 1 : 2.2. The average TAT was 48 h vs. 96 h, for IHC vs. molecular biology testing, respectively. This study showed that VE1 IHC should be a substitute for molecular biology in the initial assessment of the BRAFV600E status in MPP. This methodology needs to be set up in pathology laboratories in accordance with quality control/quality assurance accreditation procedures. Under these strict conditions the question is to know if BRAFV600E-IHC can serve not only as a prescreening tool, but also as a stand-alone test (at least in cases displaying an unequivocally staining pattern) as well as an alternative predictive test for samples for which the molecular biology failed. © 2015 European Academy of Dermatology and Venereology.

  13. Comparison of the Sensitivity of Three Methods for the Early Diagnosis of Sporotrichosis in Cats.

    PubMed

    Silva, J N; Miranda, L H M; Menezes, R C; Gremião, I D F; Oliveira, R V C; Vieira, S M M; Conceição-Silva, F; Ferreiro, L; Pereira, S A

    2018-04-01

    Sporotrichosis is caused by species of fungi within the Sporothrix schenckii complex that infect man and animals. In Rio de Janeiro, Brazil, an epidemic has been observed since 1998, with most of the cases being related to transmission from infected cats. Although the definitive diagnosis of feline sporotrichosis is made by fungal culture, cytopathological and histopathological examinations are used routinely, because the long culture period may delay treatment onset. However, alternative methods are desirable in cases of low fungal burden. Immunohistochemistry (IHC) has been described as a sensitive method for diagnosing human and canine sporotrichosis, but there are no reports of its application to cats. The aim of this study was to analyse the sensitivity of cytopathological examination (Quick Panoptic method), histopathology (Grocott silver stain) and anti-Sporothrix IHC by blinded comparisons, using fungal culture as the reference standard. Samples were collected from 184 cats with sporotrichosis that exhibited skin ulcers. The sensitivities of Grocott silver stain, cytopathological examination and IHC were 91.3%, 87.0% and 88.6%, respectively. Grocott silver stain showed the best performance. IHC showed high sensitivity, as did cytopathological examination and these may be considered as alternative methodologies. When the three methods were combined, the diagnosis was established in 180 (97.8%) out of 184 cases. Taken together, these findings indicate the need to implement these methods as routine tools for the early diagnosis of sporotrichosis in cats, notably when fungal culture is not available. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. IHC-TM connect-disconnect in relation to sensitization and masking of a HF-tone burst by a LF tone. IV.

    PubMed

    Crane, H D

    1982-05-01

    Evidence continues to accumulate that although the outer hair cells (OHCs) of the cochlea are firmly bonded to the tectorial membrane (TM), the inner hair cells (IHCS) are not. This is the fourth in a series of papers that explores how the idea of a set of disconnected hair cells that "impact" the TM is consistent with psychophysical data. The paper extends the exploration to the masking of high-frequency (HF) tone bursts by low-frequency (LF) tones and shows that the model can explain the important features of these complex data.

  15. Spindle Cell Epithelioma of the Vagina Shows Immunohistochemical Staining Supporting Its Origin From a Primitive/Progenitor Cell Population

    DTIC Science & Technology

    2001-04-01

    broader spectrum of immunohistochemical stains is presented that supports the origin of these tumors from a progenitor cell popula- tion. REPORT OF A CASE ...with S100 protein, with coexpression of cytokeratins and vimentin and expression of estrogen and progesterone receptors, as previously reported in...SCEVs. In addition, diffuse expres- sion of CD34, CD99, and Bcl-2 immunohistochemical stains was found, which has not previously been reported . The

  16. Demonstration of lipofuscin and Nissl bodies in crystal violet stained sections using a fluorescence technique or pyronin Y stain.

    PubMed

    Terr, L I

    1986-09-01

    This paper presents two simple, reliable methods for identification of lipofuscin and Nissl bodies in the same section. One method shows that lipofuscin stained with crystal violet retains its ability to fluoresce and can be observed under the fluorescence microscope after the stain has faded. Fading is accompanied by a gradual increase in the intensity of the fluorescence and is complete in about 5 min. Exciting illumination from this part of the spectrum also substantially fades staining of other autofluorescing tissue elements, such as lipids. Nonfluorescing structures, such as Nissl bodies, remain stained. By changing from transillumination with tungsten light to epifluorescent illumination and vice versa, both types of structures--Nissl bodies and lipofuscin--can be identified in the same section. The second technique uses pyronin Y for staining Nissl bodies in preparations previously stained with crystal violet. Nissl bodies are stained pink but lipofuscin remains violet. Lipofuscin in these sections also remains autofluorescent after the crystal violet stain has faded under violet or near-UV light.

  17. Secondary syphilis in HIV positive individuals: correlation with histopathologic findings, CD4 counts, and quantity of treponemes in microscopic sections.

    PubMed

    Rosa, Gabriela; Procop, Gary W; Schold, Jesse D; Piliang, Melissa P

    2016-10-01

    Although syphilis is uncommon, infection rates are much higher in HIV-infected individuals than the general population. A proposed explanation is impaired cellular immunity with HIV infection. A search of one institution yielded 10 patients with a diagnosis of secondary syphilis on skin biopsy, positive syphilis serology and available CD4 counts. We evaluated 11 biopsies from the 10 patients. We correlated the patients' CD4 counts with the histologic findings and with the number of treponemes on skin biopsies, highlighted by immunohistochemistry (IHC). We also compared the detection of spirochetes in silver stained sections (e.g. Warthin-Starry) with T. pallidum IHC. All biopsies were assessed for various histologic features. The sensitivity of IHC to detect treponemes was 64% and of silver stain was 9% (p-value 0.04). The number of treponemes on the biopsies was determined by IHC. High numbers of spirochetes (i.e. >100 per 10 hpf) were only seen in patients with CD4 counts less than 250 cells/ml. The most consistent histologic finding was a moderate to severe lymphoplasmacytic infiltrate. Although the study is small, it appears that a higher number of spirochetes is associated with CD4 counts less than 250 cell/ml. The T. pallidum IHC stain was vastly superior to the Warthin-Starry stain. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Nuclear IHC enumeration: A digital phantom to evaluate the performance of automated algorithms in digital pathology.

    PubMed

    Niazi, Muhammad Khalid Khan; Abas, Fazly Salleh; Senaras, Caglar; Pennell, Michael; Sahiner, Berkman; Chen, Weijie; Opfer, John; Hasserjian, Robert; Louissaint, Abner; Shana'ah, Arwa; Lozanski, Gerard; Gurcan, Metin N

    2018-01-01

    Automatic and accurate detection of positive and negative nuclei from images of immunostained tissue biopsies is critical to the success of digital pathology. The evaluation of most nuclei detection algorithms relies on manually generated ground truth prepared by pathologists, which is unfortunately time-consuming and suffers from inter-pathologist variability. In this work, we developed a digital immunohistochemistry (IHC) phantom that can be used for evaluating computer algorithms for enumeration of IHC positive cells. Our phantom development consists of two main steps, 1) extraction of the individual as well as nuclei clumps of both positive and negative nuclei from real WSI images, and 2) systematic placement of the extracted nuclei clumps on an image canvas. The resulting images are visually similar to the original tissue images. We created a set of 42 images with different concentrations of positive and negative nuclei. These images were evaluated by four board certified pathologists in the task of estimating the ratio of positive to total number of nuclei. The resulting concordance correlation coefficients (CCC) between the pathologist and the true ratio range from 0.86 to 0.95 (point estimates). The same ratio was also computed by an automated computer algorithm, which yielded a CCC value of 0.99. Reading the phantom data with known ground truth, the human readers show substantial variability and lower average performance than the computer algorithm in terms of CCC. This shows the limitation of using a human reader panel to establish a reference standard for the evaluation of computer algorithms, thereby highlighting the usefulness of the phantom developed in this work. Using our phantom images, we further developed a function that can approximate the true ratio from the area of the positive and negative nuclei, hence avoiding the need to detect individual nuclei. The predicted ratios of 10 held-out images using the function (trained on 32 images) are

  19. Developing and validating a model to predict the success of an IHCS implementation: the Readiness for Implementation Model.

    PubMed

    Wen, Kuang-Yi; Gustafson, David H; Hawkins, Robert P; Brennan, Patricia F; Dinauer, Susan; Johnson, Pauley R; Siegler, Tracy

    2010-01-01

    To develop and validate the Readiness for Implementation Model (RIM). This model predicts a healthcare organization's potential for success in implementing an interactive health communication system (IHCS). The model consists of seven weighted factors, with each factor containing five to seven elements. Two decision-analytic approaches, self-explicated and conjoint analysis, were used to measure the weights of the RIM with a sample of 410 experts. The RIM model with weights was then validated in a prospective study of 25 IHCS implementation cases. Orthogonal main effects design was used to develop 700 conjoint-analysis profiles, which varied on seven factors. Each of the 410 experts rated the importance and desirability of the factors and their levels, as well as a set of 10 different profiles. For the prospective 25-case validation, three time-repeated measures of the RIM scores were collected for comparison with the implementation outcomes. Two of the seven factors, 'organizational motivation' and 'meeting user needs,' were found to be most important in predicting implementation readiness. No statistically significant difference was found in the predictive validity of the two approaches (self-explicated and conjoint analysis). The RIM was a better predictor for the 1-year implementation outcome than the half-year outcome. The expert sample, the order of the survey tasks, the additive model, and basing the RIM cut-off score on experience are possible limitations of the study. The RIM needs to be empirically evaluated in institutions adopting IHCS and sustaining the system in the long term.

  20. Development of a quantitative diagnostic method of estrogen receptor expression levels by immunohistochemistry using organic fluorescent material-assembled nanoparticles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gonda, Kohsuke, E-mail: gonda@med.tohoku.ac.jp; Miyashita, Minoru; Watanabe, Mika

    2012-09-28

    Highlights: Black-Right-Pointing-Pointer Organic fluorescent material-assembled nanoparticles for IHC were prepared. Black-Right-Pointing-Pointer New nanoparticle fluorescent intensity was 10.2-fold greater than Qdot655. Black-Right-Pointing-Pointer Nanoparticle staining analyzed a wide range of ER expression levels in tissue. Black-Right-Pointing-Pointer Nanoparticle staining enhanced the quantitative sensitivity for ER diagnosis. -- Abstract: The detection of estrogen receptors (ERs) by immunohistochemistry (IHC) using 3,3 Prime -diaminobenzidine (DAB) is slightly weak as a prognostic marker, but it is essential to the application of endocrine therapy, such as antiestrogen tamoxifen-based therapy. IHC using DAB is a poor quantitative method because horseradish peroxidase (HRP) activity depends on reaction time, temperature andmore » substrate concentration. However, IHC using fluorescent material provides an effective method to quantitatively use IHC because the signal intensity is proportional to the intensity of the photon excitation energy. However, the high level of autofluorescence has impeded the development of quantitative IHC using fluorescence. We developed organic fluorescent material (tetramethylrhodamine)-assembled nanoparticles for IHC. Tissue autofluorescence is comparable to the fluorescence intensity of quantum dots, which are the most representative fluorescent nanoparticles. The fluorescent intensity of our novel nanoparticles was 10.2-fold greater than quantum dots, and they did not bind non-specifically to breast cancer tissues due to the polyethylene glycol chain that coated their surfaces. Therefore, the fluorescent intensity of our nanoparticles significantly exceeded autofluorescence, which produced a significantly higher signal-to-noise ratio on IHC-imaged cancer tissues than previous methods. Moreover, immunostaining data from our nanoparticle fluorescent IHC and IHC with DAB were compared in the same region of adjacent tissues

  1. Detection of ALK translocation in non-small cell lung carcinoma (NSCLC) and its clinicopathological significance using the Ventana immunohistochemical staining method: a single-center large-scale investigation of 1, 504 Chinese Han patients

    PubMed Central

    Yang, Lin; Ling, Yun; Guo, Lei; Ma, Di; Xue, Xuemin; Wang, Bingning; Li, Junling; Ying, Jianming

    2016-01-01

    Objective The novel fully automated immunohistochemistry (IHC) assay-Ventana anaplastic lymphoma kinase (ALK)-D5F3 for screening ALK rearrangements has been approved by China’s Food and Drug Administration in 2013, our previous study disclosed a highly specificity and sensitivity nearly 100%, and its efficacy needs to be evaluated in a large cohort of primary lung adenocarcinoma patients, and to compare clinicopathological features with ALK (+) and ALK (-) lung adenocarcinoma. Methods A total of 1,504 consecutive surgical lung adenocarcinoma cases of Chinese Han population were collected and re-diagnosed according to the 2011 multidisciplinary classification of lung adenocarcinoma. Fully automated Ventana ALK-D5F3 IHC staining with a binary scoring was adopted to evaluate staining and correlated with clinicopathological characters, including age, sex, differentiation degree, histological subtype, lymph node metastasis, and clinical staging. ALK (+) patients were followed-up, and targeted therapy of ALK-inhibitors was adopted and observed in patients with stage IV according to the NCCN guideline. Results ALK positive adenocarcinomas were identified in 6.6% of the surgically resected 1,504 NSCLCs, and significantly younger than the negative group (P<0.05).Mucinous adenocarcinoma (28.2%) was determined to be predominant in ALK (+) cases, followed by the solid type (11.7%), specific type (6.8%), papillary type (5.6%), acinar type (5.5%), and lepidic type (3.1%), and the differences were statistically significant (χ2=42.011, P<0.05). ALK (+) adenocarcinoma with lymph node metastasis (10.8%) were significantly higher than that without lymph node metastasis (4.5%) (χ2=19.809, P<0.05); and ALK (+) in phase IV (20%) was significantly higher than phase III (12.9%), phase II (4.2%), phase I (4.5%), and phase 0 (0) (χ2=36.068, P<0.05). Multivariate logistic regression disclosed that patient age, AJCC staging, and histological mucinous subtype were correlated with ALK

  2. Detection of ALK translocation in non-small cell lung carcinoma (NSCLC) and its clinicopathological significance using the Ventana immunohistochemical staining method: a single-center large-scale investigation of 1, 504 Chinese Han patients.

    PubMed

    Yang, Lin; Ling, Yun; Guo, Lei; Ma, Di; Xue, Xuemin; Wang, Bingning; Li, Junling; Ying, Jianming

    2016-10-01

    The novel fully automated immunohistochemistry (IHC) assay-Ventana anaplastic lymphoma kinase (ALK)-D5F3 for screening ALK rearrangements has been approved by China's Food and Drug Administration in 2013, our previous study disclosed a highly specificity and sensitivity nearly 100%, and its efficacy needs to be evaluated in a large cohort of primary lung adenocarcinoma patients, and to compare clinicopathological features with ALK (+) and ALK (-) lung adenocarcinoma. A total of 1,504 consecutive surgical lung adenocarcinoma cases of Chinese Han population were collected and re-diagnosed according to the 2011 multidisciplinary classification of lung adenocarcinoma. Fully automated Ventana ALK-D5F3 IHC staining with a binary scoring was adopted to evaluate staining and correlated with clinicopathological characters, including age, sex, differentiation degree, histological subtype, lymph node metastasis, and clinical staging. ALK (+) patients were followed-up, and targeted therapy of ALK-inhibitors was adopted and observed in patients with stage IV according to the NCCN guideline. ALK positive adenocarcinomas were identified in 6.6% of the surgically resected 1,504 NSCLCs, and significantly younger than the negative group (P<0.05).Mucinous adenocarcinoma (28.2%) was determined to be predominant in ALK (+) cases, followed by the solid type (11.7%), specific type (6.8%), papillary type (5.6%), acinar type (5.5%), and lepidic type (3.1%), and the differences were statistically significant (χ 2 =42.011, P<0.05). ALK (+) adenocarcinoma with lymph node metastasis (10.8%) were significantly higher than that without lymph node metastasis (4.5%) (χ 2 =19.809, P<0.05); and ALK (+) in phase IV (20%) was significantly higher than phase III (12.9%), phase II (4.2%), phase I (4.5%), and phase 0 (0) (χ 2 =36.068, P<0.05). Multivariate logistic regression disclosed that patient age, AJCC staging, and histological mucinous subtype were correlated with ALK positive staining (OR=0

  3. Development of a stain shade guide to aid the measurement of extrinsic dental stain.

    PubMed

    Gadhia, K; Shah, R; Swaminathan, D; Wetton, S; Moran, J

    2006-05-01

    Accurate and reproducible assessment of extrinsic staining is pivotal to determining efficacy of some tooth whitening oral hygiene products. The aim of this study was: (1) to produce a stain shade guide to aid the in vitro and in vivo stain assessment (2) to assess intra- and inter-examiner reproducibility of stain assessment using the stain shade guide. Using chlorhexidine and tea, perspex and acrylic teeth specimens were stained. The amount of staining on the perspex was measured with a spectrophotometer and the values obtained were assigned to the stained acrylic teeth, which were made into a stain guide. Using clinical photographs and a group of 10 volunteers, stain area and intensity were assessed using the stain guide and the recognized Lobene stain index by two examiners. The degree of intra- and inter-examiner reproducibility for these measurements were assessed using Cohen's kappa statistics. For both the clinical examination and use of photographs, intra-examiner reproducibility for stain intensity was improved when using the stain guide compared with the Lobene Index. Similarly, when assessing inter-examiner reproducibility, stain intensity kappa values were greater using the stain guide (kappa = 0.82) compared with the Lobene Index (kappa = 0.57). The findings of this study would suggest that the use of the stain guide could be of importance in the assessment of extrinsic dental stain.

  4. DNA comet Giemsa staining for conventional bright-field microscopy.

    PubMed

    Osipov, Andreyan; Arkhangelskaya, Ekaterina; Vinokurov, Alexei; Smetaninа, Nadezhda; Zhavoronkov, Alex; Klokov, Dmitry

    2014-04-10

    This study was undertaken to evaluate the compatibility of Giemsa staining protocol with the comet assay. We showed, for the first time, that DNA comets can be visualized and analyzed using Giemsa staining. We generated DNA damage dose response curves for human peripheral blood lymphocytes exposed to X-ray radiation using the comet assay with either SybrGreen I or Giemsa stain. The dose response curves were fitted by linear regressions (R2>0.977). The SybrGreen I results showed only ~1.2-fold higher slope coefficient (method sensitivity) compared to the Giemsa results. The unexpectedly high sensitivity of Giemsa staining for the comet assay is due to the Romanowsky-Giemsa effect, the stain photo-stability and the higher resolution of bright-field imaging compared to fluorescence imaging. Our results demonstrate that Giemsa staining can effectively be used for measuring DNA damage by the comet assay. The low cost and availability of Giemsa stain makes this method affordable for any low budget research and will facilitate new applications of the comet assay in biology and medicine.

  5. Sputum stain for mycobacteria

    MedlinePlus

    ... results show that the stain is positive for: Mycobacterium tuberculosis Mycobacterium avium-intracellular Other mycobacteria or acid-fast bacteria Risks There are no risks, unless bronchoscopy is performed. Alternative Names Acid fast bacilli ... Sputum test References Hopewell ...

  6. Pleural fluid Gram stain

    MedlinePlus

    Gram stain of pleural fluid ... mixing it with a violet stain (called a Gram stain). A laboratory specialist uses a microscope to ... reveals an abnormal collection of pleural fluid. The Gram stain can help identify the bacteria that might ...

  7. Discriminative staining methods for the nervous system: luxol fast blue--periodic acid-Schiff--hematoxylin triple stain and subsidiary staining methods.

    PubMed

    Goto, N

    1987-09-01

    This paper describes a new series of staining methods which can discriminatively demonstrate every structure of the nervous system, including axons and capillaries, in animal and human materials. Methods described in this paper consist of one primary stain, luxol fast blue-periodic acid Schiff-hematoxylin (LPH) and six different subsidiary staining methods. The LPH triple stain can precisely differentiate the following structures: neurons (Nissl bodies, cytoplasm, nuclear membrane and nucleolus), various kinds of nuclei (glia, ependyma, endothelium, leucocyte, connective tissue, etc.), myelin sheaths, neuronal processes (axons and dendrites), reacted glial cell bodies (protoplasmic astrocytes, foamy cells, etc.), blood vessels (arteries, veins and capillaries), meninges, intervening connective tissue, erythrocytes, lipofuscin granules, amyloid bodies, and others. Subsidiary staining methods are also described briefly. Applications are discussed in the context of staining technology and neuromorphological research.

  8. Gram staining.

    PubMed

    Coico, Richard

    2005-10-01

    Named after Hans Christian Gram who developed the method in 1884, the Gram stain allows one to distinguish between Gram-positive and Gram-negative bacteria on the basis of differential staining with a crystal violet-iodine complex and a safranin counterstain. The cell walls of Gram-positive organisms retain this complex after treatment with alcohol and appear purple, whereas gram-negative organisms decolorize following such treatment and appear pink. The method described here is useful for assessing bacterial contamination of tissue culture samples or for examining the Gram stain status and morphological features of bacteria isolated from mixed or isolated bacterial cultures.

  9. Gram staining.

    PubMed

    Coico, R

    2001-05-01

    Named after Hans Christian Gram who developed the method in 1884, the Gram stain allows one to distinguish between Gram-positive and Gram-negative bacteria on the basis of differential staining with a crystal violet-iodine complex and a safranin counterstain. The cell walls of Gram-positive organisms retain this complex after treatment with alcohol and appear purple, whereas gram-negative organisms decolorize following such treatment and appear pink. The method described here is useful for assessing bacterial contamination of tissue culture samples or for examining the Gram stain status and morphological features of bacteria isolated from mixed or isolated bacterial cultures.

  10. Parasite detection in patients with post kala-azar dermal leishmaniasis in India: a comparison between molecular and immunological methods

    PubMed Central

    Salotra, P; Sreenivas, G; Beena, K R; Mukherjee, A; Ramesh, V

    2003-01-01

    Aims: To evaluate the sensitivity and specificity of serological, immunohistochemical, and molecular methods in the diagnosis of post kala-azar dermal leishmaniasis (PKDL). Methods: Twenty five patients with confirmed PKDL and 25 controls were included in the study. G2D10, a monoclonal antibody against Leishmania, was used for the immunohistochemical (IHC) staining of lesion sections to visualise anti-Leishmania donovani antibodies. The diagnostic usefulness of IHC was compared with enzyme linked immunosorbent assay (ELISA) with a recombinant (rk39) antigen, and a species specific polymerase chain reaction (PCR) assay, amplifying a kinetoplast minicircle DNA sequence. Results: IHC detected 22 of 25 PKDL cases, giving a sensitivity of 88%. The diagnostic sensitivity of both the ELISA and PCR tests was higher (96%). All of the 25 controls examined were negative in PCR, indicating 100% specificity of the test, whereas ELISA showed 96% specificity. Conclusions: IHC with G2D10 significantly enhances the sensitivity of detection of PKDL over routine haematoxylin and eosin staining. ELISA with a recombinant antigen is an economical and practical assay. PCR is the most sensitive and specific diagnostic method for PKDL. The tests described would facilitate the recognition of patients with PKDL, enabling timely treatment, which would contribute greatly to the control of kala-azar. PMID:14600129

  11. Statistical colour models: an automated digital image analysis method for quantification of histological biomarkers.

    PubMed

    Shu, Jie; Dolman, G E; Duan, Jiang; Qiu, Guoping; Ilyas, Mohammad

    2016-04-27

    Colour is the most important feature used in quantitative immunohistochemistry (IHC) image analysis; IHC is used to provide information relating to aetiology and to confirm malignancy. Statistical modelling is a technique widely used for colour detection in computer vision. We have developed a statistical model of colour detection applicable to detection of stain colour in digital IHC images. Model was first trained by massive colour pixels collected semi-automatically. To speed up the training and detection processes, we removed luminance channel, Y channel of YCbCr colour space and chose 128 histogram bins which is the optimal number. A maximum likelihood classifier is used to classify pixels in digital slides into positively or negatively stained pixels automatically. The model-based tool was developed within ImageJ to quantify targets identified using IHC and histochemistry. The purpose of evaluation was to compare the computer model with human evaluation. Several large datasets were prepared and obtained from human oesophageal cancer, colon cancer and liver cirrhosis with different colour stains. Experimental results have demonstrated the model-based tool achieves more accurate results than colour deconvolution and CMYK model in the detection of brown colour, and is comparable to colour deconvolution in the detection of pink colour. We have also demostrated the proposed model has little inter-dataset variations. A robust and effective statistical model is introduced in this paper. The model-based interactive tool in ImageJ, which can create a visual representation of the statistical model and detect a specified colour automatically, is easy to use and available freely at http://rsb.info.nih.gov/ij/plugins/ihc-toolbox/index.html . Testing to the tool by different users showed only minor inter-observer variations in results.

  12. Analytical validation of quantitative immunohistochemical assays of tumor infiltrating lymphocyte biomarkers.

    PubMed

    Singh, U; Cui, Y; Dimaano, N; Mehta, S; Pruitt, S K; Yearley, J; Laterza, O F; Juco, J W; Dogdas, B

    2018-06-04

    Tumor infiltrating lymphocytes (TIL), especially T-cells, have both prognostic and therapeutic applications. The presence of CD8+ effector T-cells and the ratio of CD8+ cells to FOXP3+ regulatory T-cells have been used as biomarkers of disease prognosis to predict response to various immunotherapies. Blocking the interaction between inhibitory receptors on T-cells and their ligands with therapeutic antibodies including atezolizumab, nivolumab, pembrolizumab and tremelimumab increases the immune response against cancer cells and has shown significant improvement in clinical benefits and survival in several different tumor types. The improved clinical outcome is presumed to be associated with a higher tumor infiltration; therefore, it is thought that more accurate methods for measuring the amount of TIL could assist prognosis and predict treatment response. We have developed and validated quantitative immunohistochemistry (IHC) assays for CD3, CD8 and FOXP3 for immunophenotyping T-lymphocytes in tumor tissue. Various types of formalin fixed, paraffin embedded (FFPE) tumor tissues were immunolabeled with anti-CD3, anti-CD8 and anti-FOXP3 antibodies using an IHC autostainer. The tumor area of stained tissues, including the invasive margin of the tumor, was scored by a pathologist (visual scoring) and by computer-based quantitative image analysis. Two image analysis scores were obtained for the staining of each biomarker: the percent positive cells in the tumor area and positive cells/mm 2 tumor area. Comparison of visual vs. image analysis scoring methods using regression analysis showed high correlation and indicated that quantitative image analysis can be used to score the number of positive cells in IHC stained slides. To demonstrate that the IHC assays produce consistent results in normal daily testing, we evaluated the specificity, sensitivity and reproducibility of the IHC assays using both visual and image analysis scoring methods. We found that CD3, CD8 and

  13. Predominant mucosal expression of 5-HT4(+h) receptor splice variants in pig stomach and colon

    PubMed Central

    Priem, Evelien KV; De Maeyer, Joris H; Vandewoestyne, Mado; Deforce, Dieter; Lefebvre, Romain A

    2013-01-01

    epithelial and circular smooth muscle cell layer of pig colon descendens and of the epithelial cell layer of pig gastric fundus, also showed 5-HT4 receptor and GAPDH mRNA expression. No 5-HT4 receptor mRNA expression was detected in gastric LMPC-isolated EC cells from IHC stained tissues, which cells were positive for GAPDH. CONCLUSION: Porcine GI mucosa predominantly expresses 5-HT4(+h) receptor splice variants, suggesting their contribution to the 5-HT4 receptor-mediated mucosal effects of 5-HT. PMID:23840113

  14. Papanicolaou stain: Is it economical to switch to rapid, economical, acetic acid, papanicolaou stain?

    PubMed

    Dighe, Swati B; Ajit, Dulhan; Pathuthara, Saleem; Chinoy, Roshni

    2006-01-01

    To standardize an inexpensive and rapid Papanicolaou staining technique with limited ethanol usage. Smears from 200 patients were collected (2 per patient) and fixed in methanol. Half were subjected to conventional Papanicolaou and half to stain ing with rapid, economical, acetic acid Papanicolaou (REAP) stain. In REAP, pre-OG6 and post-OG6 and post-EA36 ethanol baths were replaced by 1% acetic acid and Scott's tap water with tap water. Hematoxylin was preheated to 60 degrees C. Final dehydration was with methanol. REAP smears were compared with Papanicolaou smears for optimal cytoplasmic and nuclear staining, stain preservation, cost and turnaround time. With the REAP method, cytoplasmic and nuclear staining was optimal in 181 and 192 cases, respectively. The staining time was considerably reduced, to 3 minutes, and the cost per smear was reduced to one fourth. The staining quality remained good in all the smears for > 2 years. REAP is a rapid, cost-effective alternative to Papanicolaou stain. Though low stain penetration in large cell clusters is a limitation, final interpretation was not compromised.

  15. Optimized p53 immunohistochemistry is an accurate predictor of TP53 mutation in ovarian carcinoma.

    PubMed

    Köbel, Martin; Piskorz, Anna M; Lee, Sandra; Lui, Shuhong; LePage, Cecile; Marass, Francesco; Rosenfeld, Nitzan; Mes Masson, Anne-Marie; Brenton, James D

    2016-10-01

    TP53 mutations are ubiquitous in high-grade serous ovarian carcinomas (HGSOC), and the presence of TP53 mutation discriminates between high and low-grade serous carcinomas and is now an important biomarker for clinical trials targeting mutant p53. p53 immunohistochemistry (IHC) is widely used as a surrogate for TP53 mutation but its accuracy has not been established. The objective of this study was to test whether improved methods for p53 IHC could reliably predict TP53 mutations independently identified by next generation sequencing (NGS). Four clinical p53 IHC assays and tagged-amplicon NGS for TP53 were performed on 171 HGSOC and 80 endometrioid carcinomas (EC). p53 expression was scored as overexpression (OE), complete absence (CA), cytoplasmic (CY) or wild type (WT). p53 IHC was evaluated as a binary classifier where any abnormal staining predicted deleterious TP53 mutation and as a ternary classifier where OE, CA or WT staining predicted gain-of-function (GOF or nonsynonymous), loss-of-function (LOF including stopgain, indel, splicing) or no detectable TP53 mutations (NDM), respectively. Deleterious TP53 mutations were detected in 169/171 (99%) HGSOC and 7/80 (8.8%) EC. The overall accuracy for the best performing IHC assay for binary and ternary prediction was 0.94 and 0.91 respectively, which improved to 0.97 (sensitivity 0.96, specificity 1.00) and 0.95 after secondary analysis of discordant cases. The sensitivity for predicting LOF mutations was lower at 0.76 because p53 IHC detected mutant p53 protein in 13 HGSOC with LOF mutations. CY staining associated with LOF was seen in 4 (2.3%) of HGSOC. Optimized p53 IHC can approach 100% specificity for the presence of TP53 mutation and its high negative predictive value is clinically useful as it can exclude the possibility of a low-grade serous tumour. 4.1% of HGSOC cases have detectable WT staining while harboring a TP53 LOF mutation, which limits sensitivity for binary prediction of mutation to 96%.

  16. Optimized p53 immunohistochemistry is an accurate predictor of TP53 mutation in ovarian carcinoma

    PubMed Central

    Köbel, Martin; Piskorz, Anna M; Lee, Sandra; Lui, Shuhong; LePage, Cecile; Marass, Francesco; Rosenfeld, Nitzan; Mes Masson, Anne‐Marie

    2016-01-01

    Abstract TP53 mutations are ubiquitous in high‐grade serous ovarian carcinomas (HGSOC), and the presence of TP53 mutation discriminates between high and low‐grade serous carcinomas and is now an important biomarker for clinical trials targeting mutant p53. p53 immunohistochemistry (IHC) is widely used as a surrogate for TP53 mutation but its accuracy has not been established. The objective of this study was to test whether improved methods for p53 IHC could reliably predict TP53 mutations independently identified by next generation sequencing (NGS). Four clinical p53 IHC assays and tagged‐amplicon NGS for TP53 were performed on 171 HGSOC and 80 endometrioid carcinomas (EC). p53 expression was scored as overexpression (OE), complete absence (CA), cytoplasmic (CY) or wild type (WT). p53 IHC was evaluated as a binary classifier where any abnormal staining predicted deleterious TP53 mutation and as a ternary classifier where OE, CA or WT staining predicted gain‐of‐function (GOF or nonsynonymous), loss‐of‐function (LOF including stopgain, indel, splicing) or no detectable TP53 mutations (NDM), respectively. Deleterious TP53 mutations were detected in 169/171 (99%) HGSOC and 7/80 (8.8%) EC. The overall accuracy for the best performing IHC assay for binary and ternary prediction was 0.94 and 0.91 respectively, which improved to 0.97 (sensitivity 0.96, specificity 1.00) and 0.95 after secondary analysis of discordant cases. The sensitivity for predicting LOF mutations was lower at 0.76 because p53 IHC detected mutant p53 protein in 13 HGSOC with LOF mutations. CY staining associated with LOF was seen in 4 (2.3%) of HGSOC. Optimized p53 IHC can approach 100% specificity for the presence of TP53 mutation and its high negative predictive value is clinically useful as it can exclude the possibility of a low‐grade serous tumour. 4.1% of HGSOC cases have detectable WT staining while harboring a TP53 LOF mutation, which limits sensitivity for binary prediction of

  17. Pericardial fluid Gram stain

    MedlinePlus

    ... stain To use the sharing features on this page, please enable JavaScript. Pericardial fluid Gram stain is a method of staining a sample of fluid taken from the pericardium. This is the sac surrounding ...

  18. Diagnosing periprosthetic infection: false-positive intraoperative Gram stains.

    PubMed

    Oethinger, Margret; Warner, Debra K; Schindler, Susan A; Kobayashi, Hideo; Bauer, Thomas W

    2011-04-01

    Intraoperative Gram stains have a reported low sensitivity but high specificity when used to help diagnose periprosthetic infections. In early 2008, we recognized an unexpectedly high frequency of apparent false-positive Gram stains from revision arthroplasties. The purpose of this report is to describe the cause of these false-positive test results. We calculated the sensitivity and specificity of all intraoperative Gram stains submitted from revision arthroplasty cases during a 3-month interval using microbiologic cultures of the same samples as the gold standard. Methods of specimen harvesting, handling, transport, distribution, specimen processing including tissue grinding/macerating, Gram staining, and interpretation were studied. After a test modification, results of specimens were prospectively collected for a second 3-month interval, and the sensitivity and specificity of intraoperative Gram stains were calculated. The retrospective review of 269 Gram stains submitted from revision arthroplasties indicated historic sensitivity and specificity values of 23% and 92%, respectively. Systematic analysis of all steps of the procedure identified Gram-stained but nonviable bacteria in commercial broth reagents used as diluents for maceration of periprosthetic membranes before Gram staining and culture. Polymerase chain reaction and sequencing showed mixed bacterial DNA. Evaluation of 390 specimens after initiating standardized Millipore filtering of diluent fluid revealed a reduced number of positive Gram stains, yielding 9% sensitivity and 99% specificity. Clusters of false-positive Gram stains have been reported in other clinical conditions. They are apparently rare related to diagnosing periprosthetic infections but have severe consequences if used to guide treatment. Even occasional false-positive Gram stains should prompt review of laboratory methods. Our observations implicate dead bacteria in microbiologic reagents as potential sources of false-positive Gram

  19. Can Feulgen Stain be a Reliable Biomarker over PAP Stain for Estimation of Micronuclei Score?

    PubMed Central

    Prasad, Umesh Chandra; Chandolia, Betina; Manjunath, S M; Basu, Shiva; Verma, Silvie

    2016-01-01

    Introduction Malignant transformation of the Potentially Malignant Lesions (PML) in the oral cavity is associated with elevated mortality rate because of its aggressive and exceedingly invasive nature. Meticulous diagnosis and prompt therapy of PML may help prevent malignant conversion in oral lesions. Carcinogenic insult to oral cells results in chromosomal damage and formation of Micronuclei (Mn), before the development of clinical symptoms. Aim To determine the genotoxic effect of smoking and chewing tobacco on target tissue using Mn assay and to evaluate the prevalence of other nuclear anomalies associated with it and to determine the reliability of feulgen stain for Mn assay over Papaincolau (PAP) stain. Materials and Methods PAP and feulgen staining was done to study Mn in individuals who were having tobacco habits (smoking and chewing) without lesion (n=30), individuals who were having tobacco habit (smoking and chewing) with PML (n=30) and apparently healthy subjects (n=30). Data was analysed for statistical significance using SPSS 17.0 by Kruskal - Wallis Test and Bonferronii test. Results Tobacco habits in the form of smoking and chewing have mutagenic effects on human chromosomes which is indicated by increased frequency of Mn in oral exfoliative cells. The mean Mn frequency using feulgen stain was found to be 12.27 with lesion, 10.23 with without lesion and 3.87 in controls. Whereas, metanucleated analysis revealed no significant correlation with the formation of Mn. Non-specific DNA stain (PAP) showed high numbers of Mn cells in all the groups compared to feulgen. Statistically significant difference (p<0.0001) was observed when both the stains were compared for Mn numbers. Conclusion These findings indicate that the individuals having tobacco habits (smoking and chewing) with lesion have high number of Mn cells, thus supporting the assay to be used as a reliable biomarker to assess the genotoxic effect of tobacco in the oral mucosa. The reason for

  20. Luna stain, an improved selective stain for detection of microsporidian spores in histologic sections.

    PubMed

    Peterson, Tracy S; Spitsbergen, Jan M; Feist, Stephen W; Kent, Michael L

    2011-06-16

    Microsporidia in histologic sections are most often diagnosed by observing spores in host tissues. Spores are easy to identify if they occur in large aggregates or xenomas when sections are stained with hematoxylin and eosin (H&E). However, individual spores are not frequently detected in host tissues with conventional H&E staining, particularly if spores are scattered within the tissues, areas of inflammation, or small spores in nuclei (i.e. Nucleospora salmonis). Hence, a variety of selective stains that enhance visualization of spores is recommended. We discovered that the Luna stain, used to highlight eosinophils, red blood cells, and chitin in arthropods and other invertebrates, also stains spores of Pseudoloma neurophilia. We compared this stain to the Gram, Fite's acid fast, Giemsa, and H&E stains on 8 aquatic microsporidian organisms that were readily available in our 2 laboratories: Loma salmonae, Glugea anomala, Pseudoloma neurophilia, Pleistophora hyphessobryconis, Pleistophora vermiformis, Glugea sp., Steinhausia mytilovum, and an unidentified microsporidian from UK mitten crabs Eriocheir sinensis. Based on tinctorial properties and background staining, the Luna stain performed better for detection of 6 of the 8 microsporidia. Gram stain was superior for the 2 microsporidia from invertebrates: S. mytilovum and the unidentified microsporidian from E. sinensis.

  1. Decreased expression of zonula occludens-1 and occludin in the bladder urothelium of patients with interstitial cystitis/painful bladder syndrome.

    PubMed

    Lee, Jane-Dar; Lee, Ming-Huei

    2014-01-01

    Unique barrier properties of the urothelial surface membrane permit urine storage without contents leak into the bloodstream. Previous reports suggested that the bladder urothelial barrier might be compromised in interstitial cystitis/painful bladder syndrome (IC/PBS). We examined the changes of tight junction proteins (zonula occludens-1 (ZO-1) and occludin) in IC/PBS patients. Bladder samples were derived from of 32 patients with IC/PBS and eight controls. We detected the tight junction proteins of ZO-1 and occludin expression by immunoblotting, immunohistochemical (IHC) staining and double immunofluorescent (IF) staining with confocal microscopy. Data were analyzed using the Mann-Whitney U-test. Expression of ZO-1 and occludin in the IC/PBS group was reduced compared to the control group by immunoblotting and IHC staining. Also, the thinning and denudation of urothelium were demonstrated in the IC/PBS group by histological study. IF staining showed the interruption of bladder urothelium in IC/PBS patients under confocal microscopy. Our data showed that decreased expression of tight junction proteins (ZO-1 and occludin) and interruption of bladder urothelium in IC/PBS patients. Treatment to repair the discontinuous urothelium may be useful to relieve some clinical symptoms of patients with IC/PBS. Copyright © 2012. Published by Elsevier B.V.

  2. Protocol for vital dye staining of corneal endothelial cells.

    PubMed

    Park, Sunju; Fong, Alan G; Cho, Hyung; Zhang, Cheng; Gritz, David C; Mian, Gibran; Herzlich, Alexandra A; Gore, Patrick; Morganti, Ashley; Chuck, Roy S

    2012-12-01

    To describe a step-by-step methodology to establish a reproducible staining protocol for the evaluation of human corneal endothelial cells. Four procedures were performed to determine the best protocol. (1) To determine the optimal trypan blue staining method, goat corneas were stained with 4 dilutions of trypan blue (0.4%, 0.2%, 0.1%, and 0.05%) and 1% alizarin red. (2) To determine the optimal alizarin red staining method, goat corneas were stained with 2 dilutions of alizarin red (1% and 0.5%) and 0.2% trypan blue. (3) To ensure that trypan blue truly stains damaged cells, goat corneas were exposed to either 3% hydrogen peroxide or to balanced salt solution, and then stained with 0.2% trypan blue and 0.5% alizarin red. (4) Finally, fresh human corneal buttons were examined; 1 group was stained with 0.2% trypan blue and another group with 0.4% trypan blue. For the 4 procedures performed, the results are as follows: (1) trypan blue staining was not observed in any of the normal corneal samples; (2) 0.5% alizarin red demonstrated sharper cell borders than 1% alizarin red; (3) positive trypan blue staining was observed in the hydrogen peroxide exposed tissue in damaged areas; (4) 0.4% trypan blue showed more distinct positive staining than 0.2% trypan blue. We were able to determine the optimal vital dye staining conditions for human corneal endothelial cells using 0.4% trypan blue and 0.5% alizarin red.

  3. Blood culture gram stain, acridine orange stain and direct sensitivity-based antimicrobial therapy of bloodstream infection in patients with trauma.

    PubMed

    Behera, B; Mathur, P; Gupta, B

    2010-01-01

    The purpose of this study was to ascertain if the simple practice of Gram stain, acridine orange stain and direct sensitivity determination of positive blood culture bottles could be used to guide early and appropriate treatment in trauma patients with clinical suspicion of sepsis. The study also aimed to evaluate the error in interpreting antimicrobial sensitivity by direct method when compared to standard method and find out if specific antibiotic-organism combination had more discrepancies. Findings from consecutive episodes of blood stream infection at an Apex Trauma centre over a 12-month period are summarized. A total of 509 consecutive positive blood cultures were subjected to Gram staining. AO staining was done in BacT/ALERT-positive Gram-stain negative blood cultures. Direct sensitivity was performed from 369 blood culture broths, showing single type of growth in Gram and acridine orange staining. Results of direct sensitivity were compared to conventional sensitivity for errors. No 'very major' discrepancy was found in this study. About 5.2 and 1.8% minor error rates were noted in gram-positive and gram-negative bacteria, respectively, while comparing the two methods. Most of the discrepancies in gram-negative bacteria were noted in beta lactam - beta lactamase inhibitor combinations. Direct sensitivity testing was not reliable for reporting of methicillin and vancomycin resistance in Staphylococci. Gram stain result together with direct sensitivity testing is required for optimizing initial antimicrobial therapy in trauma patients with clinical suspicion of sepsis. Gram staining and AO staining proved particularly helpful in the early detection of candidaemia.

  4. Correlation among genetic variations of c-MET in Chinese patients with non-small cell lung cancer.

    PubMed

    Duan, Jianchun; Yang, Xiaodan; Zhao, Jun; Zhuo, Minglei; Wang, Zhijie; An, Tongtong; Bai, Hua; Wang, Jie

    2018-01-05

    The purpose of our research was to determine the correlation of amplification, protein expression and somatic mutation of c-MET in IIIb-IV stage NSCLC (Non-small cell lung cancer). We also explored correlation of c-MET variation with clinical outcome. c-MET expression was observed in 28.6% (56/196) cases, and among those 13.8% (27/196) were shown to be FISH positive. Only 2.67% patients in this study carried the c-MET mutation. Cases with c-MET FISH positive were all IHC positive ,but in IHC positive cases, only half were FISH positive. Among patients with IHC 2+ staining, 35.5% was FISH positive, while cases with IHC 3+ staining,64% was FISH positive. Both protein expression and copy number of c-MET did not significantly correlate with clinical prognosis in these patients treated with EGFR-TKIs. IHC could be used as a preliminary screening method for c-MET copy number amplification and should be confirmed by FISH only in IHC positive case which facilitate selection of ALK or MET inhibitor therapy. c-MET gene copy number, protein expression and somatic mutation for exon 14 were detected by fluorescent- In-Situ -Hybridization (FISH), Immunohistochemistry (IHC), and Denaturing-High-Performance-Liquid-Chromatography (DHPLC), respectively, in 196 NSCLC patients. The relationship between c-MET abnormalities and clinical outcome of targeted therapy was analyzed by McNemar's test.

  5. Detection of BRAF mutation in Chinese tumor patients using a highly sensitive antibody immunohistochemistry assay

    NASA Astrophysics Data System (ADS)

    Qiu, Tian; Lu, Haizhen; Guo, Lei; Huang, Wenting; Ling, Yun; Shan, Ling; Li, Wenbin; Ying, Jianming; Lv, Ning

    2015-03-01

    BRAF mutations can be found in various solid tumors. But accurate and reliable screening for BRAF mutation that is compatible for clinical application is not yet available. In this study, we used an automated immunohistochemistry (IHC) staining coupled with mouse monoclonal anti-BRAF V600E (VE1) primary antibody to screen the BRAF V600E mutation in 779 tumor cases, including 611 colorectal carcinomas (CRC), 127 papillary thyroid carcinomas (PTC) and 41 malignant melanomas. Among the 779 cases, 150 cases were positive for BRAF (V600E) staining, including 38 (of 611, 6%) CRCs, 102 (of 127, 80%) PTCs and 10 (of 41, 24%) malignant melanomas. Sanger sequencing and real-time PCR confirmed the sensitivity and specificity of IHC staining for the V600E mutation are 100% and 99%, respectively. Therefore, our study demonstrates that the fully automated IHC is a reliable tool to determine BRAF mutation status in CRC, PTC and melanoma and can be used for routine clinical screen.

  6. Gauging NOTCH1 Activation in Cancer Using Immunohistochemistry

    PubMed Central

    Kluk, Michael J.; Ashworth, Todd; Wang, Hongfang; Knoechel, Birgit; Mason, Emily F.; Morgan, Elizabeth A.; Dorfman, David; Pinkus, Geraldine; Weigert, Oliver; Hornick, Jason L.; Chirieac, Lucian R.; Hirsch, Michelle; Oh, David J.; South, Andrew P.; Leigh, Irene M.; Pourreyron, Celine; Cassidy, Andrew J.; DeAngelo, Daniel J.; Weinstock, David M.; Krop, Ian E.; Dillon, Deborah; Brock, Jane E.; Lazar, Alexander J. F.; Peto, Myron; Cho, Raymond J.; Stoeck, Alexander; Haines, Brian B.; Sathayanrayanan, Sriram; Rodig, Scott; Aster, Jon C.

    2013-01-01

    Fixed, paraffin-embedded (FPE) tissues are a potentially rich resource for studying the role of NOTCH1 in cancer and other pathologies, but tests that reliably detect activated NOTCH1 (NICD1) in FPE samples have been lacking. Here, we bridge this gap by developing an immunohistochemical (IHC) stain that detects a neoepitope created by the proteolytic cleavage event that activates NOTCH1. Following validation using xenografted cancers and normal tissues with known patterns of NOTCH1 activation, we applied this test to tumors linked to dysregulated Notch signaling by mutational studies. As expected, frequent NICD1 staining was observed in T lymphoblastic leukemia/lymphoma, a tumor in which activating NOTCH1 mutations are common. However, when IHC was used to gauge NOTCH1 activation in other human cancers, several unexpected findings emerged. Among B cell tumors, NICD1 staining was much more frequent in chronic lymphocytic leukemia than would be predicted based on the frequency of NOTCH1 mutations, while mantle cell lymphoma and diffuse large B cell lymphoma showed no evidence of NOTCH1 activation. NICD1 was also detected in 38% of peripheral T cell lymphomas. Of interest, NICD1 staining in chronic lymphocytic leukemia cells and in angioimmunoblastic lymphoma was consistently more pronounced in lymph nodes than in surrounding soft tissues, implicating factors in the nodal microenvironment in NOTCH1 activation in these diseases. Among carcinomas, diffuse strong NICD1 staining was observed in 3.8% of cases of triple negative breast cancer (3 of 78 tumors), but was absent from 151 non-small cell lung carcinomas and 147 ovarian carcinomas. Frequent staining of normal endothelium was also observed; in line with this observation, strong NICD1 staining was also seen in 77% of angiosarcomas. These findings complement insights from genomic sequencing studies and suggest that IHC staining is a valuable experimental tool that may be useful in selection of patients for clinical

  7. Prospective and clinical validation of ALK immunohistochemistry: results from the phase I/II study of alectinib for ALK-positive lung cancer (AF-001JP study).

    PubMed

    Takeuchi, K; Togashi, Y; Kamihara, Y; Fukuyama, T; Yoshioka, H; Inoue, A; Katsuki, H; Kiura, K; Nakagawa, K; Seto, T; Maemondo, M; Hida, T; Harada, M; Ohe, Y; Nogami, N; Yamamoto, N; Nishio, M; Tamura, T

    2016-01-01

    Anaplastic lymphoma kinase (ALK) fusions need to be accurately and efficiently detected for ALK inhibitor therapy. Fluorescence in situ hybridization (FISH) remains the reference test. Although increasing data are supporting that ALK immunohistochemistry (IHC) is highly concordant with FISH, IHC screening needed to be clinically and prospectively validated. In the AF-001JP trial for alectinib, 436 patients were screened for ALK fusions through IHC (n = 384) confirmed with FISH (n = 181), multiplex RT-PCR (n = 68), or both (n = 16). IHC results were scored with iScore. ALK fusion was positive in 137 patients and negative in 250 patients. Since the presence of cancer cells in the samples for RT-PCR was not confirmed, ALK fusion negativity could not be ascertained in 49 patients. IHC interpreted with iScore showed a 99.4% (173/174) concordance with FISH. All 41 patients who had iScore 3 and were enrolled in phase II showed at least 30% tumor reduction with 92.7% overall response rate. Two IHC-positive patients with an atypical FISH pattern responded to ALK inhibitor therapy. The reduction rate was not correlated with IHC staining intensity. Our study showed (i) that when sufficiently sensitive and appropriately interpreted, IHC can be a stand-alone diagnostic for ALK inhibitor therapies; (ii) that when atypical FISH patterns are accompanied by IHC positivity, the patients should be considered as candidates for ALK inhibitor therapies, and (iii) that the expression level of ALK fusion is not related to the level of response to ALK inhibitors and is thus not required for patient selection. JapicCTI-101264 (This study is registered with the Japan Pharmaceutical Information Center). © The Author 2015. Published by Oxford University Press on behalf of the European Society for Medical Oncology.

  8. Prospective and clinical validation of ALK immunohistochemistry: results from the phase I/II study of alectinib for ALK-positive lung cancer (AF-001JP study)

    PubMed Central

    Takeuchi, K.; Togashi, Y.; Kamihara, Y.; Fukuyama, T.; Yoshioka, H.; Inoue, A.; Katsuki, H.; Kiura, K.; Nakagawa, K.; Seto, T.; Maemondo, M.; Hida, T.; Harada, M.; Ohe, Y.; Nogami, N.; Yamamoto, N.; Nishio, M.; Tamura, T.

    2016-01-01

    Background Anaplastic lymphoma kinase (ALK) fusions need to be accurately and efficiently detected for ALK inhibitor therapy. Fluorescence in situ hybridization (FISH) remains the reference test. Although increasing data are supporting that ALK immunohistochemistry (IHC) is highly concordant with FISH, IHC screening needed to be clinically and prospectively validated. Patients and methods In the AF-001JP trial for alectinib, 436 patients were screened for ALK fusions through IHC (n = 384) confirmed with FISH (n = 181), multiplex RT-PCR (n = 68), or both (n = 16). IHC results were scored with iScore. Result ALK fusion was positive in 137 patients and negative in 250 patients. Since the presence of cancer cells in the samples for RT-PCR was not confirmed, ALK fusion negativity could not be ascertained in 49 patients. IHC interpreted with iScore showed a 99.4% (173/174) concordance with FISH. All 41 patients who had iScore 3 and were enrolled in phase II showed at least 30% tumor reduction with 92.7% overall response rate. Two IHC-positive patients with an atypical FISH pattern responded to ALK inhibitor therapy. The reduction rate was not correlated with IHC staining intensity. Conclusions Our study showed (i) that when sufficiently sensitive and appropriately interpreted, IHC can be a stand-alone diagnostic for ALK inhibitor therapies; (ii) that when atypical FISH patterns are accompanied by IHC positivity, the patients should be considered as candidates for ALK inhibitor therapies, and (iii) that the expression level of ALK fusion is not related to the level of response to ALK inhibitors and is thus not required for patient selection. Registration number JapicCTI-101264 (This study is registered with the Japan Pharmaceutical Information Center). PMID:26487585

  9. Factor IX expression in skeletal muscle of a severe hemophilia B patient 10 years after AAV-mediated gene transfer.

    PubMed

    Buchlis, George; Podsakoff, Gregory M; Radu, Antonetta; Hawk, Sarah M; Flake, Alan W; Mingozzi, Federico; High, Katherine A

    2012-03-29

    In previous work we transferred a human factor IX-encoding adeno-associated viral vector (AAV) into skeletal muscle of men with severe hemophilia B. Biopsy of injected muscle up to 1 year after vector injection showed evidence of gene transfer by Southern blot and of protein expression by IHC and immunofluorescent staining. Although the procedure appeared safe, circulating F.IX levels remained subtherapeutic (< 1%). Recently, we obtained muscle tissue from a subject injected 10 years earlier who died of causes unrelated to gene transfer. Using Western blot, IHC, and immunofluorescent staining, we show persistent factor IX expression in injected muscle tissue. F.IX transcripts were detected in injected skeletal muscle using RT-PCR, and isolated whole genomic DNA tested positive for the presence of the transferred AAV vector sequence. This is the longest reported transgene expression to date from a parenterally administered AAV vector, with broad implications for the future of muscle-directed gene transfer.

  10. Factor IX expression in skeletal muscle of a severe hemophilia B patient 10 years after AAV-mediated gene transfer

    PubMed Central

    Buchlis, George; Podsakoff, Gregory M.; Radu, Antonetta; Hawk, Sarah M.; Flake, Alan W.; Mingozzi, Federico

    2012-01-01

    In previous work we transferred a human factor IX–encoding adeno-associated viral vector (AAV) into skeletal muscle of men with severe hemophilia B. Biopsy of injected muscle up to 1 year after vector injection showed evidence of gene transfer by Southern blot and of protein expression by IHC and immunofluorescent staining. Although the procedure appeared safe, circulating F.IX levels remained subtherapeutic (< 1%). Recently, we obtained muscle tissue from a subject injected 10 years earlier who died of causes unrelated to gene transfer. Using Western blot, IHC, and immunofluorescent staining, we show persistent factor IX expression in injected muscle tissue. F.IX transcripts were detected in injected skeletal muscle using RT-PCR, and isolated whole genomic DNA tested positive for the presence of the transferred AAV vector sequence. This is the longest reported transgene expression to date from a parenterally administered AAV vector, with broad implications for the future of muscle-directed gene transfer. PMID:22271447

  11. Quantification of protein expression in cells and cellular subcompartments on immunohistochemical sections using a computer supported image analysis system.

    PubMed

    Braun, Martin; Kirsten, Robert; Rupp, Niels J; Moch, Holger; Fend, Falko; Wernert, Nicolas; Kristiansen, Glen; Perner, Sven

    2013-05-01

    Quantification of protein expression based on immunohistochemistry (IHC) is an important step for translational research and clinical routine. Several manual ('eyeballing') scoring systems are used in order to semi-quantify protein expression based on chromogenic intensities and distribution patterns. However, manual scoring systems are time-consuming and subject to significant intra- and interobserver variability. The aim of our study was to explore, whether new image analysis software proves to be sufficient as an alternative tool to quantify protein expression. For IHC experiments, one nucleus specific marker (i.e., ERG antibody), one cytoplasmic specific marker (i.e., SLC45A3 antibody), and one marker expressed in both compartments (i.e., TMPRSS2 antibody) were chosen. Stainings were applied on TMAs, containing tumor material of 630 prostate cancer patients. A pathologist visually quantified all IHC stainings in a blinded manner, applying a four-step scoring system. For digital quantification, image analysis software (Tissue Studio v.2.1, Definiens AG, Munich, Germany) was applied to obtain a continuous spectrum of average staining intensity. For each of the three antibodies we found a strong correlation of the manual protein expression score and the score of the image analysis software. Spearman's rank correlation coefficient was 0.94, 0.92, and 0.90 for ERG, SLC45A3, and TMPRSS2, respectively (p⟨0.01). Our data suggest that the image analysis software Tissue Studio is a powerful tool for quantification of protein expression in IHC stainings. Further, since the digital analysis is precise and reproducible, computer supported protein quantification might help to overcome intra- and interobserver variability and increase objectivity of IHC based protein assessment.

  12. Ovarian Brenner tumour: a morphologic and immunohistochemical analysis suggesting an origin from fallopian tube epithelium.

    PubMed

    Kuhn, Elisabetta; Ayhan, Ayse; Shih, Ie-Ming; Seidman, Jeffrey D; Kurman, Robert J

    2013-12-01

    Brenner tumours (BTs), like other epithelial ovarian tumours, are thought to develop from the ovarian surface epithelium. We hypothesised that BTs arise from transitional metaplasia near the tuboperitoneal junction which, when embedded in the ovary as Walthard cell nests, may progress to BTs. The aim of this study was to validate this hypothesis by a morphologic and immunohistochemical (IHC) analysis. The IHC analysis revealed that fallopian tube secretory cells, transitional metaplasia, Walthard cell nests and the epithelial component of BTs shared a similar IHC profile, consistently expressing AKR1C3 (an enzyme involved in androgen biosynthesis) and androgen receptor, but not calretinin. The tumour stromal cells that immediately surrounded the epithelial nests showed strong expression of calretinin, inhibin and steroidogenic factor 1 (markers of steroidogenic cells) in the majority of BTs. Using a highly sensitive immunofluorescent staining method, we detected small groups of cilia in transitional metaplasia and Walthard cell nests, multifocal stretches of cilia and/or ciliated vacuoles in benign BTs and well-developed cilia in atypical proliferative BTs. Our findings suggest a tubal origin of BTs through transitional metaplasia and Walthard cell nests, based on their anatomic proximity, similar IHC profile and the presence of cilia. In addition, we hypothesise a role of androgenic stimulation in the pathogenesis of BT, based on the IHC staining pattern of calretinin, inhibin and steroidogenic factor 1 expressed in the luteinised stromal cells surrounding the epithelial nests of the tumours, and AKR1C3 and androgen receptor expressed in both the epithelial and stromal components. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. Gram stain method shows better sensitivity than clinical criteria for detection of bacterial vaginosis in surveillance of pregnant, low-income women in a clinical setting.

    PubMed Central

    Tam, M T; Yungbluth, M; Myles, T

    1998-01-01

    OBJECTIVE: The purpose of the study is to determine whether the Gram stain method is superior to the clinical criteria for the diagnosis of bacterial vaginosis in low-income pregnant women seen in a resident clinic setting. The clinical criteria is the current diagnostic method employed to diagnose bacterial vaginosis. STUDY DESIGN: In this study, 51 pregnant women with vaginal discharge were prospectively evaluated. All were screened using the clinical criteria, Gram stain method, and culture of the discharge. The modified scoring system instituted by Nugent et al. (J Clin Microbiol 29:297-301, 1991) was employed in reading the Gram stain smears. The clinical criteria were then compared with the Gram stain method. Isolation of moderate to many Gardnerella vaginalis growth by culture was used as the confirmatory finding. RESULTS: Sensitivity of the Gram stain method (91%) was significantly higher than that of the clinical criteria (46%), (sign test P = 0.0023, < 0.01). The Gram stain method also has both a low false-negative (4%) and high negative predictive value (96%), making it an ideal diagnostic test. CONCLUSION: The Gram stain method is a rapid and cost-effective test that is also highly reproducible and readily available in many laboratories. These features make the Gram stain method a more desirable screening procedure for bacterial vaginosis in a clinic population. PMID:9894174

  14. Multispectral image enhancement for H&E stained pathological tissue specimens

    NASA Astrophysics Data System (ADS)

    Bautista, Pinky A.; Abe, Tokiya; Yamaguchi, Masahiro; Ohyama, Nagaaki; Yagi, Yukako

    2008-03-01

    The presence of a liver disease such as cirrhosis can be determined by examining the proliferation of collagen fiber from a tissue slide stained with special stain such as the Masson's trichrome(MT) stain. Collagen fiber and smooth muscle, which are both stained the same in an H&E stained slide, are stained blue and pink respectively in an MT-stained slide. In this paper we show that with multispectral imaging the difference between collagen fiber and smooth muscle can be visualized even from an H&E stained image. In the method M KL bases are derived using the spectral data of those H&E stained tissue components which can be easily differentiated from each other, i.e. nucleus, cytoplasm, red blood cells, etc. and based on the spectral residual error of fiber weighting factors are determined to enhance spectral features at certain wavelengths. Results of our experiment demonstrate the capability of multispectral imaging and its advantage compared to the conventional RGB imaging systems to delineate tissue structures with subtle colorimetric difference.

  15. The Luna stain, an improved selective stain for detection of microsporidian spores in histologic sections

    PubMed Central

    Peterson, Tracy S.; Spitsbergen, Jan M.; Feist, Stephen W.; Kent, Michael L.

    2014-01-01

    Microsporidia in histologic sections are most often diagnosed by observing spores in host tissues. Spores are easy to identify if they occur in large aggregates or xenomas when sections are stained with hematoxylin and eosin (H&E). However, individual spores are not frequently detected in host tissues with conventional H&E staining, particularly if spores are scattered within the tissues, areas of inflammation or small spores in nuclei (i.e., Nucleospora salmonis). Hence, a variety of selective stains that enhance visualization of spores are recommended. We discovered that the Luna stain, used to highlight eosinophils, red blood cells and chitin in arthropods and other invertebrates, also stains spores of Pseudoloma neurophilia. We compared this stain to the Gram, Fite’s acid fast, Giemsa, and H&E stains on eight aquatic microsporidian organisms that were readily available in our two laboratories: Loma salmonae, Glugea anomala, Pseudoloma neurophilia, Pleistophora hyphessobryconis, Pleistophora vermiformis, Glugea sp., Steinhausia mytilovum and an unidentified microsporidian from E. sinensis, UK. Based on tinctorial properties and background staining, the Luna stain performed better for detection of 6 of the 8 microsporidia. Gram stain was superior for the two microsporidia from invertebrates, Steinhausia mytilovum and the unidentified microsporidian from E. sinensis. PMID:21848126

  16. Utility of Gram staining for diagnosis of Malassezia folliculitis.

    PubMed

    Tu, Wei-Ting; Chin, Szu-Ying; Chou, Chia-Lun; Hsu, Che-Yuan; Chen, Yu-Tsung; Liu, Donald; Lee, Woan-Ruoh; Shih, Yi-Hsien

    2018-02-01

    Malassezia folliculitis (MalF) mimics acne vulgaris and bacterial folliculitis in clinical presentations. The role of Gram staining in rapid diagnosis of MalF has not been well studied. In our study, 32 patients were included to investigate the utility of Gram staining for MalF diagnosis. The final diagnoses of MalF were determined according to clinical presentation, pathological result and treatment response to antifungal agents. Our results show that the sensitivity and specificity of Gram staining are 84.6% and 100%, respectively. In conclusion, Gram staining is a rapid, non-invasive, sensitive and specific method for MalF diagnosis. © 2017 Japanese Dermatological Association.

  17. Utility of Modified Ultrafast Papanicolaou Stain in Cytological Diagnosis

    PubMed Central

    Arakeri, Surekha Ulhas

    2017-01-01

    Introduction Need for minimal turnaround time for assessing Fine Needle Aspiration Cytology (FNAC) has encouraged innovations in staining techniques that require lesser staining time with unequivocal cell morphology. The standard protocol for conventional Papanicolaou (PAP) stain requires about 40 minutes. To overcome this, Ultrafast Papanicolaou (UFP) stain was introduced which reduces staining time to 90 seconds and also enhances the quality. However, reagents required for this were not easily available hence, Modified Ultrafast Papanicolaou (MUFP) stain was introduced subsequently. Aim To assess the efficacy of MUFP staining by comparing the quality of MUFP stain with conventional PAP stain. Materials and Methods FNAC procedure was performed by using 10 ml disposable syringe and 22-23 G needle. Total 131 FNAC cases were studied which were lymph node (30), thyroid (38), breast (22), skin and soft tissue (24), salivary gland (11) and visceral organs (6). Two smears were prepared and stained by MUFP and conventional PAP stain. Scores were given on four parameters: background of smears, overall staining pattern, cell morphology and nuclear staining. Quality Index (QI) was calculated from ratio of total score achieved to maximum score possible. Statistical analysis using chi square test was applied to each of the four parameters before obtaining the QI in both stains. Students t-test was applied to evaluate the efficacy of MUFP in comparison with conventional PAP stain. Results The QI of MUFP for thyroid, breast, lymph node, skin and soft tissue, salivary gland and visceral organs was 0.89, 0.85, 0.89, 0.83, 0.92, and 0.78 respectively. Compared to conventional PAP stain QI of MUFP smears was better in all except visceral organ cases and was statistically significant. MUFP showed clear red blood cell background, transparent cytoplasm and crisp nuclear features. Conclusion MUFP is fast, reliable and can be done with locally available reagents with unequivocal

  18. Utility of Modified Ultrafast Papanicolaou Stain in Cytological Diagnosis.

    PubMed

    Sinkar, Prachi; Arakeri, Surekha Ulhas

    2017-03-01

    Need for minimal turnaround time for assessing Fine Needle Aspiration Cytology (FNAC) has encouraged innovations in staining techniques that require lesser staining time with unequivocal cell morphology. The standard protocol for conventional Papanicolaou (PAP) stain requires about 40 minutes. To overcome this, Ultrafast Papanicolaou (UFP) stain was introduced which reduces staining time to 90 seconds and also enhances the quality. However, reagents required for this were not easily available hence, Modified Ultrafast Papanicolaou (MUFP) stain was introduced subsequently. To assess the efficacy of MUFP staining by comparing the quality of MUFP stain with conventional PAP stain. FNAC procedure was performed by using 10 ml disposable syringe and 22-23 G needle. Total 131 FNAC cases were studied which were lymph node (30), thyroid (38), breast (22), skin and soft tissue (24), salivary gland (11) and visceral organs (6). Two smears were prepared and stained by MUFP and conventional PAP stain. Scores were given on four parameters: background of smears, overall staining pattern, cell morphology and nuclear staining. Quality Index (QI) was calculated from ratio of total score achieved to maximum score possible. Statistical analysis using chi square test was applied to each of the four parameters before obtaining the QI in both stains. Students t-test was applied to evaluate the efficacy of MUFP in comparison with conventional PAP stain. The QI of MUFP for thyroid, breast, lymph node, skin and soft tissue, salivary gland and visceral organs was 0.89, 0.85, 0.89, 0.83, 0.92, and 0.78 respectively. Compared to conventional PAP stain QI of MUFP smears was better in all except visceral organ cases and was statistically significant. MUFP showed clear red blood cell background, transparent cytoplasm and crisp nuclear features. MUFP is fast, reliable and can be done with locally available reagents with unequivocal morphology which is the need of the hour for a cytopathology set-up.

  19. Port-wine stain

    MedlinePlus

    ... Laser therapy is most successful in removing port-wine stains. It is the only method that can destroy the tiny blood vessels in the skin without causing much damage to the skin. The exact type ... on the person's age, skin type, and particular port-wine stain.

  20. Detection of the multiphoton signals in stained tissue using nonlinear optical microscopy

    NASA Astrophysics Data System (ADS)

    Zeng, Yaping; Xu, Jian; Kang, Deyong; Lin, Jiangbo; Chen, Jianxin

    2016-10-01

    Multiphoton microscopy (MPM) based on two-photon excited fluorescence (TPEF) and second harmonic generation (SHG) imaging, has become a powerful, important tool for tissue imaging at the molecular level. Recently, MPM is also used to image hematoxylin and eosin (H and E)-stained sections in cancer diagnostics. However, several studies have showed that the MPM images of tissue stained with H and E are significantly different from unstained tissue sections. Our aim was to detect of the multiphoton signals in stained tissue by using MPM. In this paper, MPM was used to image histological sections of esophageal invasive carcinoma tissues stained with H, E, H and E and fresh tissue. To detect of the multiphoton signals in stained tissue, the emission spectroscopic of tissue stained with H, E, H and E were obtained. For comparison, the fresh tissues were also investigated. Our results showed that the tissue stained with H, E, H and E could be detected by their TPEF signals. While the tissue stained with H and fresh tissue could be detected by their TPEF and SHG signals. In this work, we detect of the multiphoton signals in stained tissue. These findings will be useful for choosing suitable staining method so to improve the quality of MPM imaging in the future.

  1. Investigating Various Thresholds as Immunohistochemistry Cutoffs for Observer Agreement.

    PubMed

    Ali, Asif; Bell, Sarah; Bilsland, Alan; Slavin, Jill; Lynch, Victoria; Elgoweini, Maha; Derakhshan, Mohammad H; Jamieson, Nigel B; Chang, David; Brown, Victoria; Denley, Simon; Orange, Clare; McKay, Colin; Carter, Ross; Oien, Karin A; Duthie, Fraser R

    2017-10-01

    Clinical translation of immunohistochemistry (IHC) biomarkers requires reliable and reproducible cutoffs or thresholds for interpretation of immunostaining. Most IHC biomarker research focuses on the clinical relevance (diagnostic, prognostic, or predictive utility) of cutoffs, with less emphasis on observer agreement using these cutoffs. From the literature, we identified 3 commonly used cutoffs of 10% positive epithelial cells, 20% positive epithelial cells, and moderate to strong staining intensity (+2/+3 hereafter) to use for investigating observer agreement. A series of 36 images of microarray cores stained for 4 different IHC biomarkers, with variable staining intensity and percentage of positive cells, was used for investigating interobserver and intraobserver agreement. Seven pathologists scored the immunostaining in each image using the 3 cutoffs for positive and negative staining. Kappa (κ) statistic was used to assess the strength of agreement for each cutoff. The interobserver agreement between all 7 pathologists using the 3 cutoffs was reasonably good, with mean κ scores of 0.64, 0.59, and 0.62, respectively, for 10%, 20%, and +2/+3 cutoffs. A good agreement was observed for experienced pathologists using the 10% cutoff, and their agreement was statistically higher than for junior pathologists (P=0.02). In addition, the mean intraobserver agreement for all 7 pathologists using the 3 cutoffs was reasonably good, with mean κ scores of 0.71, 0.60, and 0.73, respectively, for 10%, 20%, and +2/+3 cutoffs. For all 3 cutoffs, a positive correlation was observed with perceived ease of interpretation (P<0.003). Finally, cytoplasmic-only staining achieved higher agreement using all 3 cutoffs than mixed staining patterns. All 3 cutoffs investigated achieve reasonable strength of agreement, modestly decreasing interobserver and intraobserver variability in IHC interpretation. These cutoffs have previously been used in cancer pathology, and this study provides

  2. Methods for chromosome-specific staining

    DOEpatents

    Gray, J.W.; Pinkel, D.

    1995-09-05

    Methods and compositions for chromosome-specific staining are provided. Compositions comprise heterogeneous mixtures of labeled nucleic acid fragments having substantially complementary base sequences to unique sequence regions of the chromosomal DNA for which their associated staining reagent is specific. Methods include ways for making the chromosome-specific staining compositions of the invention, and methods for applying the staining compositions to chromosomes. 3 figs.

  3. Methods for chromosome-specific staining

    DOEpatents

    Gray, Joe W.; Pinkel, Daniel

    1995-01-01

    Methods and compositions for chromosome-specific staining are provided. Compositions comprise heterogenous mixtures of labeled nucleic acid fragments having substantially complementary base sequences to unique sequence regions of the chromosomal DNA for which their associated staining reagent is specific. Methods include methods for making the chromosome-specific staining compositions of the invention, and methods for applying the staining compositions to chromosomes.

  4. The Immunohistochemistry and Toluidine Blue Roles for Helicobacter pylori Detection in Patients with Gastritis

    PubMed Central

    Tajalli, Raziye; Nobakht, Maliheh; Mohammadi-Barzelighi, Hajar; Agah, Shahram; Rastegar-Lari, Abdolaziz; Sadeghipour, Alireza

    2013-01-01

    Background: Helicobacter pylori, which is associated with many upper gastrointestinal diseases, is found in half of the population of the world. Several special stains and immunohistochemistry stain for H. pylori are available. The need for and usefulness of immunohistochemical (IHC) technique has been debated for years. Toluidine blue is a simple stain for microbiological studies and is easily available in laboratories. Therefore, this study was conducted to compare hematoxylin and eosin (H&E), Giemsa and toluidine blue staining with immunehistochemistry for detection of H. pylori in patients with gastritis and also to correlate the results of these staining methods with pathological grading. Methods: We reviewed 54 consecutive gastric biopsy specimens stained by H&E and Giemsa as well as by toluidine blue and immunohistochemistry stains for H. pylori. Results: H. pylori was positively identified by IHC in 43 (79.63%) patients, while positive samples were found in 18 (33.33%), 24 (44.44%) and 33 (61.11%) patients using H&E, Giemsa and toluidine blue staining methods. Our results showed that classical histological staining methods are not sensitive enough to identify low numbers or coccoid forms of organism, while toluidine blue and immunohistochemistry play an important role in detection of H. pylori infection. Conclusion: Toluidine blue has been proved to be much more reliable than H&E and Giemsa in detection of H. pylori. In addition, in post treatment biopsies and in biopsies with unexplained chronic active gastritis without histological evidence of H. pylori should have immunohistochemistry done to detect possible low density or coccoid form of organisms. PMID:23279833

  5. Efficacy test of a toothpaste in reducing extrinsic dental stain

    NASA Astrophysics Data System (ADS)

    Agustanti, A.; Ramadhani, S. A.; Adiatman, M.; Rahardjo, A.; Callea, M.; Yavuz, I.; Maharani, D. A.

    2017-08-01

    This clinical trial compared the external dental stain reduction achieved by tested toothpaste versus placebo in adult patients. In this double-blind, parallel, randomised clinical trial, 45 female volunteers with a mean age of 20 years old were included. All study subjects front teeth were topically applicated with Silver Diamine Fluoride (SDF) to create external dental stains. Subjects were randomized into test (n=22) and control (n=23) groups. Toothpastes were used for two days to analyse the effects of removing external stains on the labial surfaces of all anterior teeth. VITA Easyshade Advance 4.0 was used to measure dental extrinsic stains changes. The analysis showed statistically significant efficacy of the tested toothpaste in reducing external dental stain caused by SDF, comparing to the placebo toothpaste, after one and two days of usage. The tested toothpaste was effective in reducing dental stain.

  6. Automated single-slide staining system

    NASA Technical Reports Server (NTRS)

    Mills, S. M.; Wilkins, J. R.

    1974-01-01

    Apparatus developed to Gram-stain single slides automatically is flexible enough to accommodate other types of staining procedures. Method frees operator and eliminates necessity for subjective evaluations as to length of staining or decolorizing time.

  7. BRAFV600E mutation in the diagnosis of unicystic ameloblastoma.

    PubMed

    Pereira, Núbia Braga; Pereira, Karuza Maria Alves; Coura, Bruna Pizziolo; Diniz, Marina Gonçalves; de Castro, Wagner Henriques; Gomes, Carolina Cavalieri; Gomez, Ricardo Santiago

    2016-11-01

    Unicystic ameloblastoma, an odontogenic neoplasm, presents clinical and radiographic similarities with dentigerous and radicular cysts, non-neoplastic lesions. It is not always possible to reach a final diagnosis with the incisional biopsy, leading to inappropriate treatment. The BRAFV600E activating mutation has been reported in a high proportion of ameloblastomas. The purpose of the study was to assess the utility of the detection of the BRAFV600E mutation in the differential diagnosis of unicystic ameloblastoma with dentigerous and radicular cysts. Twenty-six archival samples were included, comprising eight unicystic ameloblastomas (UAs), nine dentigerous and nine radicular cysts. The mutation was assessed in all samples by anti-BRAFV600E (clone VE1) immunohistochemistry (IHC) and by TaqMan mutation detection qPCR assay. Sanger sequencing was further carried out when samples showed conflicting results in the IHC and qPCR. Although all UAs (8/8) showed positive uniform BRAFV600E staining along the epithelial lining length, the mutation was not confirmed by qPCR and Sanger sequencing in three samples. Positive staining for the BRAFV600E protein was observed in one dentigerous cyst, but it was not confirmed by the molecular methods. Furthermore, 2/9 dentigerous cysts and 2/9 radicular cysts showed non-specific immunostaining of the epithelium or plasma cells. None of the dentigerous or radicular cysts cases presented the BRAFV600E mutation in the qPCR assay. The BRAFV600E antibody (clone VE1) IHC may show non-specific staining, but molecular assays may be useful for the diagnosis of unicystic ameloblastoma, in conjunction with clinical, radiological and histopathological features. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Ultrastructural Investigation of Pelvic Peritoneum in Patients With Chronic Pelvic Pain and Subtle Endometriosis in Association With Chromoendoscopy.

    PubMed

    Mehdizadehkashi, Abolfazl; Tahermanesh, Kobra; Fazel Anvari-Yazdi, Abbas; Chaichian, Shahla; Azarpira, Negar; Nobakht, Maliheh; Abed, Seyedeh Mehr; Hashemi, Neda

    2017-01-01

    To evaluate the pelvic peritoneum under chromoendoscopy by scanning electron microscopy (SEM) as well as light microscopy with hematoxylin and eosin staining and immunohistochemistry (IHC) assays in patients with chronic pelvic pain (CPP) associated with subtle endometriosis. Case series study (Canadian Task Force classification II). A referral academic community tertiary medical center. Three women aged 29 to 37 years were referred to the obstetrics and gynecology clinic of the tertiary university hospital with CPP. They were suspicious for endometriosis, were not responding to medical treatments, and had undergone previous pelvic laparoscopy to determine the stage of endometriosis and preparation of peritoneal samples under the guidance of staining with methylene blue in 0.25% dilution. Comparison of stained and unstained pelvic peritoneal samples after the instillation of 0.25% methylene blue into the pelvic cavity. In 3 patients, laparoscopic examination showed minimal endometriosis. A total of 18 samples (9 stained and 9 unstained) from the 3 patients were prepared for SEM. Ten of the samples (55.6%) showed microstructural peritoneal destruction (7 of 9 stained [77.7%] and 3 of 9 [33.4%] unstained). Eighteen samples (9 stained and 9 unstained) from the 3 patients were also prepared for IHC. Six of these samples (33.3%) were S-100-positive, including 4 of 9 (44.4%) stained samples and 2 of 9 (22.2%) unstained samples. In general, in the context of CPP and endometriosis, there is no established relationship between the severity of pain and stage of endometriosis. In the pathophysiology of CPP associated with endometriosis, ultrastructural changes can play a significant role. Under methylene blue staining, some destroyed areas were detected, but the stained areas do not necessarily correlate with increased microstructural peritoneal destruction. Copyright © 2016 AAGL. Published by Elsevier Inc. All rights reserved.

  9. Gram staining for the treatment of peritonsillar abscess.

    PubMed

    Takenaka, Yukinori; Takeda, Kazuya; Yoshii, Tadashi; Hashimoto, Michiko; Inohara, Hidenori

    2012-01-01

    Objective. To examine whether Gram staining can influence the choice of antibiotic for the treatment of peritonsillar abscess. Methods. Between 2005 and 2009, a total of 57 cases of peritonsillar abscess were analyzed with regard to cultured bacteria and Gram staining. Results. Only aerobes were cultured in 16% of cases, and only anaerobes were cultured in 51% of cases. Mixed growth of aerobes and anaerobes was observed in 21% of cases. The cultured bacteria were mainly aerobic Streptococcus, anaerobic Gram-positive cocci, and anaerobic Gram-negative rods. Phagocytosis of bacteria on Gram staining was observed in 9 cases. The bacteria cultured from these cases were aerobic Streptococcus, anaerobic Gram-positive cocci, and anaerobic Gram-negative rods. The sensitivity of Gram staining for the Gram-positive cocci and Gram-negative rods was 90% and 64%, respectively. The specificity of Gram staining for the Gram-positive cocci and Gram-negative rods was 62% and 76%, respectively. Most of the Gram-positive cocci were sensitive to penicillin, but some of anaerobic Gram-negative rods were resistant to penicillin. Conclusion. When Gram staining shows only Gram-positive cocci, penicillin is the treatment of choice. In other cases, antibiotics effective for the penicillin-resistant organisms should be used.

  10. Gram stain of tissue biopsy

    MedlinePlus

    ... biopsy To use the sharing features on this page, please enable JavaScript. Gram stain of tissue biopsy test involves using crystal violet stain to test a sample of tissue taken from a biopsy . The Gram stain method can ...

  11. Use of Murine Bioassay to Resolve Ovine Transmissible Spongiform Encephalopathy Cases Showing a Bovine Spongiform Encephalopathy Molecular Profile

    PubMed Central

    Beck, Katy E; Sallis, Rosemary E; Lockey, Richard; Vickery, Christopher M; Béringue, Vincent; Laude, Hubert; Holder, Thomas M; Thorne, Leigh; Terry, Linda A; Tout, Anna C; Jayasena, Dhanushka; Griffiths, Peter C; Cawthraw, Saira; Ellis, Richard; Balkema-Buschmann, Anne; Groschup, Martin H; Simmons, Marion M; Spiropoulos, John

    2012-01-01

    Two cases of unusual transmissible spongiform encephalopathy (TSE) were diagnosed on the same farm in ARQ/ARQ PrP sheep showing attributes of both bovine spongiform encephalopathy (BSE) and scrapie. These cases, UK-1 and UK-2, were investigated further by transmissions to wild-type and ovine transgenic mice. Lesion profiles (LP) on primary isolation and subpassage, incubation period (IP) of disease, PrPSc immunohistochemical (IHC) deposition pattern and Western blot profiles were used to characterize the prions causing disease in these sheep. Results showed that both cases were compatible with scrapie. The presence of BSE was contraindicated by the following: LP on primary isolation in RIII and/or MR (modified RIII) mice; IP and LP after serial passage in wild-type mice; PrPSc deposition pattern in wild-type mice; and IP and Western blot data in transgenic mice. Furthermore, immunohistochemistry (IHC) revealed that each case generated two distinct PrPSc deposition patterns in both wild-type and transgenic mice, suggesting that two scrapie strains coexisted in the ovine hosts. Critically, these data confirmed the original differential IHC categorization that these UK-1 and UK-2 cases were not compatible with BSE. PMID:21919992

  12. Diagnosis of Inherited Epidermolysis Bullosa in Resource-Limited Settings: Immunohistochemistry Revisited.

    PubMed

    Yenamandra, Vamsi Krishna; Bhari, Neetu; Ray, Subrata Basu; Sreenivas, Vishnubhatla; Dinda, Amit Kumar; Scaria, Vinod; Sharma, Vinod Kumar; Sethuraman, Gomathy

    2017-01-01

    Immunofluorescence (IFM) antigen mapping is the most commonly used technique to diagnose and differentiate epidermolysis bullosa (EB). In India, IFM is limited to few research laboratories and is not readily available, making the diagnosis largely clinical and often inaccurate. Ob jective of the Study: To examine the diagnostic usefulness of immunohistochemistry (IHC) as compared to IFM in resource-limited settings. Forty-four consecutive EB patients were included in this study. IHC and IFM were performed on 7-µm frozen tissue sections using standard laboratory protocols with a limited panel of antibodies. The kappa coefficient of agreement was calculated with genetic analysis as the gold standard. IFM and IHC accurately identified the subtype of EB in 80.9% (p < 0.001) of the cases, when a clear blister cavity was evident on biopsy. The sensitivities and specificities of IHC and IFM for diagnosing EB simplex, junctional EB, and dystrophic EB were 100, 100, and 60% and 82.4, 100, and 100%, respectively. IHC was equally effective (p < 0.001) in establishing the type of EB as IFM. IHC staining and its interpretation were simple and comparable to IFM. IHC had an advantage of showing subtle changes in the epidermal architecture that could not be appreciated on IFM and hence can be considered useful in resource-limited settings. © 2017 S. Karger AG, Basel.

  13. 'Ease of interpretation' of cytological smears stained with modified ultrafast papanicolaou stain: Interobserver agreement and reproducibility.

    PubMed

    Uthamalingam, Preithy; Sathish Kumar, Thabasum; Venus, Albina; Sekar, Preethi; Muthusamy, Rajeshwari K; Mehta, Sangita

    2018-04-01

    Since its inception in 1995, the Ultrafast Papanicoloau (UFPAP) cytological stain has undergone a number of modifications to suit the local availability of reagents and cost in different set ups. However, the reported results have been uniformly encouraging. We designed a study to investigate the inter-observer agreement in 'perceived ease of interpretation' of cytological smears stained with Modified Ultrafast Papanicoloau stain (MUFPAP). After a small pilot study, we prospectively stained air-dried fine needle aspirate smears (FNACs) and Body Fluid smears with the standardized MUFPAP stain. The MUFPAP stained slides were evaluated in tandem with other routine cytological stains as well as independently by two pathologists. Two rater kappa was used to determine the agreement. The study included 93 fluids and 34 FNACs. A vast majority of the cases stained with MUFPAP were rated 'better' than the routine stains in terms of 'overall ease of interpretation' with considerable agreement. The agreement tended to be better for FNACs than fluid specimens. Cases with malignant pathology demonstrated a perfect agreement (kappa = 1) between the raters in terms of 'overall ease of interpretation' (91.7% cases were rated 'very good' by each pathologist) when compared to cases with benign pathology (kappa = 0.52). Nuclear characteristics were appreciated with a better agreement than other parameters. Modified UFPAP stain appears to be quick, reliable, cost-effective alternative in cytology, especially for detecting malignant cells in smears with low cellularity. Its specific advantage is robust nuclear staining against a clear background. © 2018 Wiley Periodicals, Inc.

  14. Free digital image analysis software helps to resolve equivocal scores in HER2 immunohistochemistry.

    PubMed

    Helin, Henrik O; Tuominen, Vilppu J; Ylinen, Onni; Helin, Heikki J; Isola, Jorma

    2016-02-01

    Evaluation of human epidermal growth factor receptor 2 (HER2) immunohistochemistry (IHC) is subject to interobserver variation and lack of reproducibility. Digital image analysis (DIA) has been shown to improve the consistency and accuracy of the evaluation and its use is encouraged in current testing guidelines. We studied whether digital image analysis using a free software application (ImmunoMembrane) can assist in interpreting HER2 IHC in equivocal 2+ cases. We also compared digital photomicrographs with whole-slide images (WSI) as material for ImmunoMembrane DIA. We stained 750 surgical resection specimens of invasive breast cancers immunohistochemically for HER2 and analysed staining with ImmunoMembrane. The ImmunoMembrane DIA scores were compared with the originally responsible pathologists' visual scores, a researcher's visual scores and in situ hybridisation (ISH) results. The originally responsible pathologists reported 9.1 % positive 3+ IHC scores, for the researcher this was 8.4 % and for ImmunoMembrane 9.5 %. Equivocal 2+ scores were 34 % for the pathologists, 43.7 % for the researcher and 10.1 % for ImmunoMembrane. Negative 0/1+ scores were 57.6 % for the pathologists, 46.8 % for the researcher and 80.8 % for ImmunoMembrane. There were six false positive cases, which were classified as 3+ by ImmunoMembrane and negative by ISH. Six cases were false negative defined as 0/1+ by IHC and positive by ISH. ImmunoMembrane DIA using digital photomicrographs and WSI showed almost perfect agreement. In conclusion, digital image analysis by ImmunoMembrane can help to resolve a majority of equivocal 2+ cases in HER2 IHC, which reduces the need for ISH testing.

  15. Black stains in the mixed dentition: a PCR microbiological study of the etiopathogenic bacteria.

    PubMed

    Saba, C; Solidani, M; Berlutti, F; Vestri, A; Ottolenghi, L; Polimeni, A

    2006-01-01

    The aim of this work is to emphasize that particular stains on the third cervical of the buccal and lingual surfaces in mixed dentition, called "black stain." Previous research showed the microbiological etiology of this discoloration by chromogen bacterias. Our study shows bacteria spp involved in stains by means of PCR process and electrophoresis gel on the agarose medium. Sample was formed by 100 subject with black stain and 100 control subjects stain-free. A statistical analysis (SPSS 10.0) using X2 was performed in this study. Porphyromonas gingivalis and Prevotella melaninogenica, were not involved in both in black stain subjects and in the control. On the contrary, Actinomyces could be involved in the pigmentation process.

  16. Histology and immunohistochemistry of severe inflammatory bowel disease versus lymphoma in the ferret (Mustela putorius furo).

    PubMed

    Watson, Megan K; Cazzini, Paola; Mayer, Joerg; Gottdenker, Nicole; Reavill, Drury; Parry, Nicola; Fox, James G; Sakamoto, Kaori

    2016-05-01

    Inflammatory bowel disease (IBD) is a common disorder of ferrets (Mustela putorius furo) that may progress to lymphoma. Although routine histology is used to distinguish between these diseases, misclassifications may occur. Immunohistochemistry (IHC) is commonly used to distinguish between IBD and lymphoma in small animals. The objective of our study was to determine the agreement in the diagnosis reached solely using hematoxylin and eosin (HE)-stained, full-thickness sections versus using a combination of HE and IHC. Enteric sections from 44 ferrets previously diagnosed with IBD or intestinal lymphoma and 3 control ferrets were analyzed by pathologists with expertise in ferrets. A pathologist blinded to the original diagnosis assessed the same HE-stained sections. Analysis was then repeated using HE sections in parallel with sections stained using antibodies against CD3 and CD79a. No significant difference was found between the original HE diagnosis and the HE diagnosis reached by the blinded pathologist (p = 0.91) or between the blinded pathologist's HE versus HE with IHC diagnosis (p = 0.16). In the 2 cases where disagreement was present, IHC was pivotal in reaching a final diagnosis. There was no significant age (p = 0.29) difference between diagnoses; however, significantly more male ferrets were affected with IBD than females (p = 0.004). Immunophenotype of the lymphoma was not correlated with predilection for location in the intestinal wall (p = 0.44). Results suggest that although IHC is not necessary to distinguish IBD from intestinal lymphoma in ferrets, it can be useful a definitive diagnosis in cases of severe IBD. © 2016 The Author(s).

  17. COMPARISON OF PERMANENT STAINING METHODS FOR THE LABORATORY DIAGNOSIS OF TRICHOMONIASIS

    PubMed Central

    MENEZES, Camila Braz; MELLO, Mariana dos Santos; TASCA, Tiana

    2016-01-01

    Trichomonas vaginalis is the etiologic agent of trichomoniasis, the most common non-viral sexually transmitted disease (STD) in the world. The diagnosis is based on wet mount preparation and direct microscopy on fixed and stained clinical specimens. The aim of this study was to compare the performance of different fixing and staining techniques used in the detection of T. vaginalis in urine. The smears were fixed and submitted to different methods of permanent staining and then, the morphological aspects of the parasites were analyzed and compared. The Papanicolaou staining with ethanol as the fixative solution showed to be the best method of permanent staining. Our data suggest that staining techniques in association with wet mount examination of fresh specimens contribute to increase the sensitivity in the diagnosis of trichomoniasis. PMID:26910452

  18. Flat Urothelial Lesions With Atypia: Interobserver Concordance and Added Value of Immunohistochemical Profiling.

    PubMed

    Lawless, Margaret E; Tretiakova, Maria S; True, Lawrence D; Vakar-Lopez, Funda

    2018-03-01

    Distinguishing urothelial carcinoma in situ (CIS) from other flat lesions of the urinary bladder with cytologic atypia is critically important for the management of patients with bladder neoplasia. However, there is high interpathologist variability in making these distinctions. The aim of this study is to assess interobserver agreement between general and specialized genitourinary pathologists, and to compare these diagnoses with those rendered after an immunohistochemical panel is performed. We hypothesized that addition of a set of immunohistochemical stains would reduce the number of cases classified within intermediate categories of atypia of uncertain significance and low-grade dysplasia. Two genitourinary pathologists independently assessed haematoxylin and eosin (H&E)-stained sections of 127 bladder biopsies from each of the 4 International Society of Urological Pathology/World Health Organization categories of flat lesions diagnosed by general pathologists. A subset of biopsies from 49 patients was reassessed after staining with a 3-antibody panel (CD44, CK20, and p53) and the results were correlated with patient follow-up. Based on these immunohistochemistry (IHC) stains, 26 cases (53.1%) were recategorized. Of most clinical importance, 5 of 27 cases (18.5%) originally diagnosed as either atypia of uncertain significance or low-grade dysplasia were recategorized as CIS, and recurrent disease was identified on subsequent biopsies. None of the 10 cases diagnosed as CIS based on H&E stains were recategorized. This triad of IHC stains can improve the precision of pathologic diagnosis of histologically atypical urothelial lesions of flat bladder mucosa. We recommend that pathologists apply this set of IHC stains to such lesions they find problematic based on H&E stains.

  19. Laryngeal squamous cell papilloma is highly associated with human papillomavirus.

    PubMed

    Orita, Yorihisa; Gion, Yuka; Tachibana, Tomoyasu; Ikegami, Kana; Marunaka, Hidenori; Makihara, Seiichiro; Yamashita, Yasuhiko; Miki, Kentaro; Makino, Takuma; Akisada, Naoki; Akagi, Yusuke; Kimura, Miyuki; Yoshino, Tadashi; Nishizaki, Kazunori; Sato, Yasuharu

    2018-04-01

    To delineate the association between characteristics of adult-onset laryngeal squamous cell papilloma and human papillomavirus (HPV) infection. Clinical records and paraffin-embedded specimens of 77 papilloma patients who had been treated between 1998 and 2014 were collected. Of the 77 cases, 34 were identified in the larynx, 28 in the oral cavity and 15 in the oropharynx. Specimens were investigated by polymerase chain reaction (PCR) to detect HPV 6, 11, 16, 18, 31, 33, 35, 52b and 58, and immunohistochemical (IHC) staining for anti-p16INK4a antibody. In 21 cases (61.8%) with laryngeal squamous cell papilloma, various types of HPV were detected: 14 cases (41.2%) were positive of high-risk HPV, 18 (52.9%) were positive of low-risk HPV and 11 (32.4%) were positive of both high-risk HPV and low-risk HPV. Younger patients (<60 years) showed a higher rate of HPV infection than older patients. Among the 34 cases with laryngeal papilloma, no malignant transformation was observed during the study period. With IHC staining, positive expression of p16 was observed in 20 cases (58.8%). HPV infection and p16-expression were associated with the pathological finding of koilocytosis. Only four cases (14.3%) showed HPV-positivity in the oral cavity, and none of the 15 oropharyngeal cases were positive for HPV, and none of the oral cavity and oropharyngeal cases showed koilocytosis. Results of HPV-PCR and p16-IHC staining were significantly correlated each other. HPV infection is frequently associated with laryngeal squamous cell papilloma, and koilocytosis is a characteristic pathological finding. To the best of our knowledge, this is the first report which have described infections with multiple HPV types in laryngeal papilloma.

  20. Albumin expression distinguishes bile duct adenomas from metastatic adenocarcinoma.

    PubMed

    Moy, Andrea P; Arora, Kshitij; Deshpande, Vikram

    2016-09-01

    Bile duct adenomas may be difficult to distinguish from metastatic carcinomas, particularly well-differentiated pancreatic ductal adenocarcinoma. Prior studies have evaluated the utility of various immunohistochemical markers, although these markers are notable for low sensitivity and/or specificity. The aim of this study was to investigate the utility of albumin and BRAFV600E expression in distinguishing between metastatic pancreatic adenocarcinoma and bile duct adenoma. We studied 26 bile duct adenomas, three bile duct hamartomas, and 158 pancreatic ductal adenocarcinomas. Branched-chain in-situ hybridization (bISH) for albumin was performed; bISH is based on the branched DNA technology, wherein signal amplification is achieved via a series of sequential steps. Additionally, BRAFV600E immunohistochemistry (IHC) was performed on a subset of cases. Twenty-three of 25 (92%) bile duct adenomas were positive for albumin; 18 (72%) showed diffuse staining, and five showed focal staining (20%), including two challenging examples. Two bile duct hamartomas also stained positively. All pancreatic adenocarcinomas were negative for albumin. Seven of 16 (44%) bile duct adenomas and five of 106 (5%) pancreatic ductal adenocarcinomas were positive for BRAFV600E by IHC. The sensitivity and specificity of expression of albumin, as detected by bISH, for distinguishing bile duct adenomas from metastatic pancreatic adenocarcinomas were 92% and 100%, respectively; the sensitivity and specificity of BRAFV600E IHC for distinguishing bile duct adenomas from metastatic pancreatic adenocarcinomas were 43.8% and 95.3%, respectively. Diagnostically challenging examples of bile duct adenoma may be distinguished from metastatic pancreatic adenocarcinoma by the use of albumin bISH. © 2016 John Wiley & Sons Ltd.

  1. Comparison of PD-L1 mRNA Expression Measured with the CheckPoint Typer® Assay with PD-L1 Protein Expression Assessed with Immunohistochemistry in Non-small Cell Lung Cancer.

    PubMed

    Erber, Ramona; Stöhr, Robert; Herlein, Stefanie; Giedl, Claudia; Rieker, Ralf Joachim; Fuchs, Florian; Ficker, Joachim H; Hartmann, Arndt; Veltrup, Elke; Wirtz, Ralph M; Brueckl, Wolfgang M

    2017-12-01

    Immunohistochemical (IHC) assessment of programmed death-ligand 1 (PD-L1) in non-small cell lung cancer (NSCLC) has become important since the development of anti-PD-1/-PD-L1 directed drugs. Various PD-L1 antibodies and cut-offs have been used in different trials to predict response to these drugs, thus comparison of those studies is difficult. We compared PD-L1 mRNA expression measured by RT-qPCR with PD-L1 protein expression evaluated by IHC. Moreover, we investigated the impact of different tumour tissue acquisition methods on the reliability of PD-L1 measurement techniques. NSCLC cases (N=22), including n=9 mediastinal lymph node biopsies acquired by endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) and n=5 metastases, were evaluated prospectively for PD-L1 protein on tumor cells (TC) and immune cells (IC) using E1L3N and 28-8 antibodies and PD-L1 mRNA using the CheckPoint TYPER® assay. In primary NSCLC tissues, agreement between PD-L1 mRNA and TC staining using the 28-8 antibody was excellent (ĸ=0.85, p=0.0002). Comparing both PD-L1 antibodies against each other showed a kappa value of 0.58 (p=0.0106). In EBUS-TBNA, PD-L1 mRNA correlated perfectly with the 28-8 antibody (ĸ=1.0, p=0.0023). PD-L1 mRNA levels significantly differed when comparing 28-8 TC staining of tumours >49% with 1-49% and 0% (p=0.0040; p=0.0081, respectively). In metastatic lesions, differences between PD-L1 mRNA and IHC became apparent (ĸ=0.2, p=0.2525). Testing of PD-L1 mRNA and 28-8 IHC showed an excellent agreement in NSCLC samples including mediastinal lymph node biopsies. Since PD-L1 expression in >50% TC detected by 28-8 IHC can be reliably detected by RT-qPCR, quantitative PD-L1 mRNA determination should be considered as an alternative to IHC as there is no interobserver variability in RNA results. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  2. Pregnancy outcomes in women with chronic endometritis and recurrent pregnancy loss.

    PubMed

    McQueen, Dana B; Perfetto, Candice O; Hazard, Florette K; Lathi, Ruth B

    2015-10-01

    To evaluate the prevalence of chronic endometritis (CE) in women with recurrent pregnancy loss (RPL) and compare pregnancy outcomes in women with and without CE. Case-control observational study. Academic fertility practice. Women with two or more pregnancy losses. Hematoxylin and eosin (H & E) staining was performed on all endometrial biopsies and plasma cells were identified by morphology. Immunohistochemical (IHC) staining for CD138 was later applied to all tissue samples. Charts were reviewed to evaluate the outcome of the next clinical intrauterine pregnancy. Miscarriage rate and live birth rate. A total of 107 women met inclusion criteria. The use of CD138 IHC staining resulted in a significantly higher prevalence of CE compared with the use of H & E staining and morphological assessment alone (56% [60/107] vs. 13% [14/107]). The 51 women with untreated CE were compared with the 45 women without CE by CD138 staining. Among those women with a subsequent pregnancy, the live birth rate in the next clinical intrauterine pregnancy after endometrial evaluation was 67.6% (23/34) in women with untreated CE and 87.1% (27/31) in women without CE. Age, body mass index (BMI), results of RPL evaluation, and number of prior losses were not significantly different between the two groups. CD138 IHC staining of endometrial biopsies in women with RPL provides increased sensitivity when screening for CE compared with H & E staining and morphological assessment alone. Untreated CE may contribute to poor pregnancy outcomes and deserves further investigation in a larger cohort. Copyright © 2015 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  3. Organotin Dyes Bearing Anionic Boron Clusters as Cell-Staining Fluorescent Probes.

    PubMed

    Muñoz-Flores, Blanca M; Cabrera-González, Justo; Viñas, Clara; Chávez-Reyes, Arturo; Dias, H V Rasika; Jiménez-Pérez, Víctor M; Núñez, Rosario

    2018-04-11

    Within the cell nucleus, in the nucleoli, ribosomal RNAs are synthesized and participate in several biological processes. To better understand nucleoli-related processes, their visualization is often required, for which specific markers are needed. Herein, we report the design of novel fluorescent organotin compounds derived from 4-hydroxy-N'-((2-hydroxynaphthalen-1-yl)methylene)benzohydrazide and their cytoplasm and nucleoli staining of B16F10 cells in vitro. Tin compounds bearing an aliphatic carbon chain (-C 12 H 25 ) and an electron-donating group (-OH) were prepared, and the latter could be derivatized to bear the boron cluster anions [B 12 H 12 ] 2- and [3,3'-Co(1,2-C 2 B 9 H 11 ) 2 ] - (COSAN). All of the conjugates have been fully characterized and their luminescence properties have been assessed. In general, they show good quantum yields in solution (24-49 %), those for the COSAN derivatives being lower. Remarkably, the linking of [B 12 H 12 ] 2- and COSAN to the complexes made them more soluble, without being detrimental to their luminescence properties. Living B16F10 cells were treated with all of the compounds to determine their fluorescence staining properties; the compounds bearing the aliphatic chain showed a reduced staining capacity due to the formation of aggregates. Notably, the complexes bearing different boron clusters showed different staining effects; those bearing [B 12 H 12 ] 2- showed extraordinary staining of the nucleoli and cytoplasm, whereas those bearing COSAN were only detected in the cytoplasm. The remarkable fluorescence staining properties shown by these organotin compounds make them excellent candidates for fluorescence bioimaging in vitro. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Platinum blue staining of cells grown in electrospun scaffolds.

    PubMed

    Yusuf, Mohammed; Millas, Ana Luiza G; Estandarte, Ana Katrina C; Bhella, Gurdeep K; McKean, Robert; Bittencourt, Edison; Robinson, Ian K

    2014-01-01

    Fibroblast cells grown in electrospun polymer scaffolds were stained with platinum blue, a heavy metal stain, and imaged using scanning electron microscopy. Good contrast on the cells was achieved compared with samples that were gold sputter coated. The cell morphology could be clearly observed, and the cells could be distinguished from the scaffold fibers. Here we optimized the required concentration of platinum blue for imaging cells grown in scaffolds and show that a higher concentration causes platinum aggregation. Overall, platinum blue is a useful stain for imaging cells because of its enhanced contrast using scanning electron microscopy (SEM). In the future it would be useful to investigate cell growth and morphology using three-dimensional imaging methods.

  5. Validation of 31 of the most commonly used immunohistochemical antibodies in cytology prepared using the Cellient(®) automated cell block system.

    PubMed

    Montgomery, Eric; Gao, Chen; de Luca, Julie; Bower, Jessie; Attwood, Kristropher; Ylagan, Lourdes

    2014-12-01

    The Cellient(®) cell block system has become available as an alternative, partially automated method to create cell blocks in cytology. We sought to show a validation method for immunohistochemical (IHC) staining on the Cellient cell block system (CCB) in comparison with the formalin fixed paraffin embedded traditional cell block (TCB). Immunohistochemical staining was performed using 31 antibodies on 38 patient samples for a total of 326 slides. Split samples were processed using both methods by following the Cellient(®) manufacturer's recommendations for the Cellient cell block (CCB) and the Histogel method for preparing the traditional cell block (TCB). Interpretation was performed by three pathologists and two cytotechnologists. Immunohistochemical stains were scored as: 0/1+ (negative) and 2/3+ (positive). Inter-rater agreement for each antibody was evaluated for CCB and TCB, as well as the intra-rater agreement between TCB and CCB between observers. Interobserver staining concordance for the TCB was obtained with statistical significance (P < 0.05) in 24 of 31 antibodies. Interobserver staining concordance for the CCB was obtained with statistical significance in 27 of 31 antibodies. Intra-observer staining concordance between TCB and CCB was obtained with statistical significance in 24 of 31 antibodies tested. In conclusions, immunohistochemical stains on cytologic specimens processed by the Cellient system are reliable and concordant with stains performed on the same split samples processed via a formalin fixed-paraffin embedded (FFPE) block. The Cellient system is a welcome adjunct to cytology work-flow by producing cell block material of sufficient quality to allow the use of routine IHC. © 2014 Wiley Periodicals, Inc.

  6. Negative Stains Containing Trehalose: Application to Tubular and Filamentous Structures

    NASA Astrophysics Data System (ADS)

    Harris, J. Robin; Gerber, Max; Gebauer, Wolfgang; Wernicke, Wolfgang; Markl, Jürgen

    1996-02-01

    Several examples are presented that show the successful application of uranyl acetate and ammonium molybdate negative staining in the presence of trehalose for TEM studies of filamentous and tubular structures. The principal benefit to be gained from the inclusion of trehalose stems from the considerably reduced flattening of the large tubular structures and the greater orientational freedom of single molecules due to an increased depth of the negative stain in the presence of trehalose. Trehalose is likely to provide considerable protection to protein molecules and their assemblies during the drying of negatively stained specimens. Some reduction in the excessive density imparted by uranyl acetate around large assemblies is also achieved. Nevertheless, in the presence of 1% (w/v) trehalose, it is desirable to increase the concentration of negative stain to 5% (w/v) for ammonium molybdate and to 4% for uranyl acetate to produce satisfactory image contrast. In general, the ammonium molybdate-trehalose negative stain is more satisfactory than the uranyl acetate-trehalose combination, because of the greater electron beam sensitivity of the uranyl negative stain. Reassembled taxol-stabilized pig brain microtubules, together with collagen fibrils, sperm tails, helical filaments, and reassociated hemocyanin (KLH2), all from the giant keyhole limpet Megathura crenulata, have been studied by negative staining in the presence of trehalose. In all cases satisfactory TEM imaging conditions were readily obtained on the specimens, as long as regions of excessively deep stain were avoided.

  7. Interobserver variation in CD30 immunohistochemistry interpretation; consequences for patient selection for targeted treatment.

    PubMed

    Koens, Lianne; van de Ven, Peter M; Hijmering, Nathalie J; Kersten, Marie José; Diepstra, Arjan; Chamuleau, Martine; de Jong, Daphne

    2018-05-14

    CD30 immunohistochemistry (IHC) in malignant lymphoma is used for selection of patients in clinical trials using brentuximab vedotin, an antibody drug-conjugate targeting the CD30 molecule. For reliable implementation in daily practice and meaningful selection of patients for clinical trials, information on technical variation and interobserver reproducibility of CD30 IHC staining is required. We conducted a 3-round reproducibility assessment of CD30 scoring for categorized frequency and intensity, including a technical validation, a "live polling" pre- and post-instruction scoring round, and a web-based round including individual scoring with additional IHC information to mimic daily diagnostic practice. Agreement in all three scoring rounds was poor to fair (κ=0,12 to 0,35 for CD30 positive tumor cell percentage, and κ=0,16 to 0,41 for staining intensity), even when allowing for one category of freedom in percentage of tumor cell positivity (κ=0,30 to 0,61). The first round with CD30 staining performed in 5 independent laboratories showed objective differences in staining intensity. In the second round, about half of the pathologists changed their opinion on CD30 frequency after a discussion on potential pitfalls, highlighting hesitancy in decision-making. Using fictional cut-off points for percentage of tumor cell positivity, agreement was still suboptimal (κ=0,35 to 0,60). Lack of agreement in cases with heterogeneous expression is shown to influence patient eligibility for treatment with brentuximab vedotin both in clinical practice and within the context of clinical trials, and limits the potential predictive value of the relative frequency of CD30 positive neoplastic cells for clinical response. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  8. Safer staining method for acid fast bacilli.

    PubMed Central

    Ellis, R C; Zabrowarny, L A

    1993-01-01

    To develop a method for staining acid fast bacilli which excluded highly toxic phenol from the staining solution. A lipophilic agent, a liquid organic detergent, LOC High Studs, distributed by Amway, was substituted. The acid fast bacilli stained red; nuclei, cytoplasm, and cytoplasmic elements stained blue on a clear background. These results compare very favourably with acid fast bacilli stained by the traditional method. Detergents are efficient lipophilic agents and safer to handle than phenol. The method described here stains acid fast bacilli as efficiently as traditional carbol fuchsin methods. LOC High Suds is considerably cheaper than phenol. Images PMID:7687254

  9. Safer staining method for acid fast bacilli.

    PubMed

    Ellis, R C; Zabrowarny, L A

    1993-06-01

    To develop a method for staining acid fast bacilli which excluded highly toxic phenol from the staining solution. A lipophilic agent, a liquid organic detergent, LOC High Studs, distributed by Amway, was substituted. The acid fast bacilli stained red; nuclei, cytoplasm, and cytoplasmic elements stained blue on a clear background. These results compare very favourably with acid fast bacilli stained by the traditional method. Detergents are efficient lipophilic agents and safer to handle than phenol. The method described here stains acid fast bacilli as efficiently as traditional carbol fuchsin methods. LOC High Suds is considerably cheaper than phenol.

  10. A Novel Contrast Stain for the Rapid Diagnosis of Pityriasis Versicolor: A Comparison of Chicago Sky Blue 6B Stain, Potassium Hydroxide Mount and Culture.

    PubMed

    Lodha, Nikita; Poojary, Shital Amin

    2015-01-01

    The mycological study of pityriasis versicolor is usually done by potassium hydroxide (KOH) mount and culture. However, KOH mount lacks a color contrast and requires a trained eye to interpret, while culture is difficult to perform, time consuming and has low sensitivity. Chicago Sky Blue 6B (CSB) is a new contrast stain that highlights the fungal hyphae and spores, blue against a purplish background. This study was done to compare the utility of a novel contrast stain (CSB stain) with KOH mount and culture. Skin scrapings from the lesions of 100 clinically diagnosed cases of P. versicolor were subjected to (1) KOH mount and CSB stain for direct microscopic examination and (2) culture using Sabouraud's dextrose agar. The statistical analysis of CSB stain and culture was done using KOH mount as the reference method, as it is the most commonly performed and practical diagnostic test available for P. versicolor. An interrater reliability analysis using the Cohen's Kappa statistic was performed to determine consistency (agreement) among the different modalities. Direct microscopy with CSB stain, KOH mount and mycological culture showed positive results in 98 (98%), 92 (92%) and 56 (56%) patients, respectively. Using KOH mount as the reference method, CSB stain had a sensitivity of 100% which was significantly higher than culture (60.9%). Statistically significant fair agreement was found between CSB stain and KOH mount (94% with κ=0.38, P < 0.001). Negligible agreement was found between CSB stain and culture (66%, κ=0.199, P = 0.001) as well as between KOH mount and culture (64%, κ=0.051, P = 0.107). CSB staining of skin scrapings is the most sensitive method for the diagnosis of pityriasis versicolor. Due to the distinct contrast provided by CSB, it is easy to perform, rapid and qualitatively superior to KOH mount.

  11. Fully Automated Fluorescent in situ Hybridization (FISH) Staining and Digital Analysis of HER2 in Breast Cancer: A Validation Study

    PubMed Central

    van der Logt, Elise M. J.; Kuperus, Deborah A. J.; van Setten, Jan W.; van den Heuvel, Marius C.; Boers, James. E.; Schuuring, Ed; Kibbelaar, Robby E.

    2015-01-01

    HER2 assessment is routinely used to select patients with invasive breast cancer that might benefit from HER2-targeted therapy. The aim of this study was to validate a fully automated in situ hybridization (ISH) procedure that combines the automated Leica HER2 fluorescent ISH system for Bond with supervised automated analysis with the Visia imaging D-Sight digital imaging platform. HER2 assessment was performed on 328 formalin-fixed/paraffin-embedded invasive breast cancer tumors on tissue microarrays (TMA) and 100 (50 selected IHC 2+ and 50 random IHC scores) full-sized slides of resections/biopsies obtained for diagnostic purposes previously. For digital analysis slides were pre-screened at 20x and 100x magnification for all fluorescent signals and supervised-automated scoring was performed on at least two pictures (in total at least 20 nuclei were counted) with the D-Sight HER2 FISH analysis module by two observers independently. Results were compared to data obtained previously with the manual Abbott FISH test. The overall agreement with Abbott FISH data among TMA samples and 50 selected IHC 2+ cases was 98.8% (κ = 0.94) and 93.8% (κ = 0.88), respectively. The results of 50 additionally tested unselected IHC cases were concordant with previously obtained IHC and/or FISH data. The combination of the Leica FISH system with the D-Sight digital imaging platform is a feasible method for HER2 assessment in routine clinical practice for patients with invasive breast cancer. PMID:25844540

  12. Iron Stain on Wood

    Treesearch

    Mark Knaebe

    2013-01-01

    Iron stain, an unsightly blue–black or gray discoloration, can occur on nearly all woods. Oak, redwood, cypress, and cedar are particularly prone to iron stain because these woods contain large amounts of tannin-like extractives. The discoloration is caused by a chemical reaction between extractives in the wood and iron in steel products, such as nails, screws, and...

  13. Histological Stains: A Literature Review and Case Study

    PubMed Central

    Alturkistani, Hani A; Tashkandi, Faris M; Mohammedsaleh, Zuhair M

    2016-01-01

    The history of histology indicates that there have been significant changes in the techniques used for histological staining through chemical, molecular biology assays and immunological techniques, collectively referred to as histochemistry. Early histologists used the readily available chemicals to prepare tissues for microscopic studies; these laboratory chemicals were potassium dichromate, alcohol and the mercuric chloride to harden cellular tissues. Staining techniques used were carmine, silver nitrate, Giemsa, Trichrome Stains, Gram Stain and Hematoxylin among others. The purpose of this research was to assess past and current literature reviews, as well as case studies, with the aim of informing ways in which histological stains have been improved in the modern age. Results from the literature review has indicated that there has been an improvement in histopathology and histotechnology in stains used. There has been a rising need for efficient, accurate and less complex staining procedures. Many stain procedures are still in use today, and many others have been replaced with new immunostaining, molecular, non-culture and other advanced staining techniques. Some staining methods have been abandoned because the chemicals required have been medically proven to be toxic. The case studies indicated that in modern histology a combination of different stain techniques are used to enhance the effectiveness of the staining process. Currently, improved histological stains, have been modified and combined with other stains to improve their effectiveness. PMID:26493433

  14. Histological Stains: A Literature Review and Case Study.

    PubMed

    Alturkistani, Hani A; Tashkandi, Faris M; Mohammedsaleh, Zuhair M

    2015-06-25

    The history of histology indicates that there have been significant changes in the techniques used for histological staining through chemical, molecular biology assays and immunological techniques, collectively referred to as histochemistry. Early histologists used the readily available chemicals to prepare tissues for microscopic studies; these laboratory chemicals were potassium dichromate, alcohol and the mercuric chloride to harden cellular tissues. Staining techniques used were carmine, silver nitrate, Giemsa, Trichrome Stains, Gram Stain and Hematoxylin among others. The purpose of this research was to assess past and current literature reviews, as well as case studies, with the aim of informing ways in which histological stains have been improved in the modern age. Results from the literature review has indicated that there has been an improvement in histopathology and histotechnology in stains used. There has been a rising need for efficient, accurate and less complex staining procedures. Many stain procedures are still in use today, and many others have been replaced with new immunostaining, molecular, non-culture and other advanced staining techniques. Some staining methods have been abandoned because the chemicals required have been medically proven to be toxic. The case studies indicated that in modern histology a combination of different stain techniques are used to enhance the effectiveness of the staining process. Currently, improved histological stains, have been modified and combined with other stains to improve their effectiveness.

  15. Ghost mycobacteria on Gram stain.

    PubMed Central

    Trifiro, S; Bourgault, A M; Lebel, F; René, P

    1990-01-01

    The Gram stain is a key tool in diagnostic microbiology. Its usefulness with respect to mycobacteria is undefined. The neutrality of mycobacteria other than Mycobacterium tuberculosis on Gram staining of various clinical specimens is described. Images PMID:1688872

  16. A procedure for Alcian blue staining of mucins on polyvinylidene difluoride membranes.

    PubMed

    Dong, Weijie; Matsuno, Yu-ki; Kameyama, Akihiko

    2012-10-16

    The isolation and characterization of mucins are critically important for obtaining insight into the molecular pathology of various diseases, including cancers and cystic fibrosis. Recently, we developed a novel membrane electrophoretic method, supported molecular matrix electrophoresis (SMME), which separates mucins on a polyvinylidene difluoride (PVDF) membrane impregnated with a hydrophilic polymer. Alcian blue staining is widely used to visualize mucopolysaccharides and acidic mucins on both blotted membranes and SMME membranes; however, this method cannot be used to stain mucins with a low acidic glycan content. Meanwhile, periodic acid-Schiff staining can selectively visualize glycoproteins, including mucins, but is incompatible with glycan analysis, which is indispensable for mucin characterizations. Here we describe a novel staining method, designated succinylation-Alcian blue staining, for visualizing mucins on a PVDF membrane. This method can visualize mucins regardless of the acidic residue content and shows a sensitivity 2-fold higher than that of Pro-Q Emerald 488, a fluorescent periodate Schiff-base stain. Furthermore, we demonstrate the compatibility of this novel staining procedure with glycan analysis using porcine gastric mucin as a model mucin.

  17. Gram Stain

    MedlinePlus

    ... Cancer Therapy Glucose Tests Gonorrhea Testing Gram Stain Growth Hormone Haptoglobin hCG Pregnancy hCG Tumor Marker HDL Cholesterol ... Semen Analysis Serotonin Serum Free Light Chains Sex Hormone Binding Globulin ... Transferrin Receptor Stool Culture Stool Elastase Strep ...

  18. Is quantitative oestrogen receptor expression useful in the evaluation of the clinical prognosis? Analysis of a homogeneous series of 797 patients with prospective determination of the ER status using simultaneous EIA and IHC.

    PubMed

    Mazouni, Chafika; Bonnier, Pascal; Goubar, Aïcha; Romain, Sylvie; Martin, Pierre-Marie

    2010-10-01

    Oestrogen receptor (ER) determination in breast cancer (BC) is a major yardstick for the prognosis and for response to hormonal therapy (HT). As several techniques have been proposed for ER quantification, the purpose of our study was to assess whether the qualitative or quantitative analysis of ER expression might influence the prognosis and response to treatment. We analysed overall survival (OS) and disease-free survival (DFS) in 797 primary BC cases with ER determination by enzyme immunoassay (EIA) and immunohistochemistry (IHC). The clinical impact according to qualitative or quantitative analysis of ER expression was assessed. Response to HT was evaluated according to quantitative EIA-determined ER expression levels. According to the qualitative analysis of ER expression, patients with EIA-determined and IHC-determined ER-positive tumours had significantly longer OS and DFS (p<0.001). The analysis stratified on quartiles of ER levels showed significantly different outcomes according to EIA- and IHC-determined subgroups. In the group of patients who received adjuvant treatment, 5-year OS was significantly different between the groups, with a clear benefit for the highest EIA-determined ER quartiles (p<0.001). Comparatively, in terms of 5-year DFS, a clear separation was noted between groups for adjuvant treatment (p<0.001). The group with moderate ER+ values was clearly distinct from the ER-negative population. Quantitative ER expression helped to better distinguish the beneficial or detrimental effect of HT within quartiles of ER-expressing tumours. Based on the STEPP analysis which showed a trend towards an ER effect on DFS as a function of HT assignment, we confirm the benefit of HT in patients with a very high EIA-determined ER level and a detrimental impact on negative and weakly positive groups. Quantitative ER expression in BC helps to better discriminate heterogeneity in clinical outcome and response to HT. Copyright © 2010 Elsevier Ltd. All rights

  19. Silver stain for electron microscopy

    NASA Technical Reports Server (NTRS)

    Corbett, R. L.

    1972-01-01

    Ammoniacal silver stain used for light microscopy was adapted advantageously for use with very thin biological sections required for electron microscopy. Silver stain can be performed in short time, has more contrast, and is especially useful for low power electron microscopy.

  20. Centrifuge-operated specimen staining method and apparatus

    NASA Technical Reports Server (NTRS)

    Feeback, Daniel L. (Inventor); Clarke, Mark S. F. (Inventor)

    1999-01-01

    A method of staining preselected, mounted specimens of either biological or nonbiological material enclosed within a staining chamber where the liquid staining reagents are applied and removed from the staining chamber using hypergravity as the propelling force. In the preferred embodiment, a spacecraft-operated centrifuge and method of diagnosing biological specimens while in orbit, characterized by hermetically sealing a shell assembly. The assembly contains slide stain apparatus with computer control therefor, the operative effect of which is to overcome microgravity, for example on board an International Space Station.

  1. A flow-cytometric gram-staining technique for milk-associated bacteria.

    PubMed

    Holm, Claus; Jespersen, Lene

    2003-05-01

    A Gram-staining technique combining staining with two fluorescent stains, Oregon Green-conjugated wheat germ agglutinin (WGA) and hexidium iodide (HI) followed by flow-cytometric detection is described. WGA stains gram-positive bacteria while HI binds to the DNA of all bacteria after permeabilization by EDTA and incubation at 50 degrees C for 15 min. For WGA to bind to gram-positive bacteria, a 3 M potassium chloride solution was found to give the highest fluorescence intensity. A total of 12 strains representing some of the predominant bacterial species in bulk tank milk and mixtures of these were stained and analyzed by flow cytometry. Overall, the staining method showed a clear differentiation between gram-positive and gram-negative bacterial populations. For stationary-stage cultures of seven gram-positive bacteria and five gram-negative bacteria, an average of 99% of the cells were correctly interpreted. The method was only slightly influenced by the growth phase of the bacteria or conditions such as freezing at -18 degrees C for 24 h. For any of these conditions, an average of at least 95% of the cells were correctly interpreted. When stationary-stage cultures were stored at 5 degrees C for 14 days, an average of 86% of the cells were correctly interpreted. The Gram-staining technique was applied to the flow cytometry analysis of bulk tank milk inoculated with Staphylococcus aureus and Escherichia coli. These results demonstrate that the technique is suitable for analyzing milk samples without precultivation.

  2. Methods and compositions for chromosome-specific staining

    DOEpatents

    Gray, Joe W.; Pinkel, Daniel

    2003-07-22

    Methods and compositions for chromosome-specific staining are provided. Compositions comprise heterogenous mixtures of labeled nucleic acid fragments having substantially complementary base sequences to unique sequence regions of the chromosomal DNA for which their associated staining reagent is specific. Methods include methods for making the chromosome-specific staining compositions of the invention, and methods for applying the staining compositions to chromosomes.

  3. Comparison of methylene blue/gentian violet stain to Gram's stain for the rapid diagnosis of gonococcal urethritis in men.

    PubMed

    Taylor, Stephanie N; DiCarlo, Richard P; Martin, David H

    2011-11-01

    We compared a simple, one-step staining procedure using a mixture of methylene blue and gentian violet to Gram stain for the detection of gonococcal urethritis. The sensitivity and specificity of both Gram stain and methylene blue/gentian violet stain were 97.3% and 99.6%, respectively. There was a 100% correlation between the 2 methods.

  4. Detecting Tie2, an endothelial growth factor receptor, by using immunohistochemistry in mouse lungs.

    PubMed

    Guha, Prajna P; David, Sascha A; Ghosh, Chandra C

    2014-01-01

    Immunohistochemical (IHC) staining is an invaluable, sensitive, and effective method to detect the presence and localization of proteins in the cellular compartment in tissues. The basic concept of IHC is detecting the antigen in tissues by means of specific antibody binding, which is then demonstrated with a colored histochemical reaction that can be observed under a light microscope. The most challenging aspect of IHC techniques is optimizing the precise experimental conditions that are required to get a specific and a strong signal. The critical steps of IHC are specimen acquisition, fixation, permeabilization, detection system, and selection of the antigen specific antibody and its optimization. Here, we elaborate the technique using the endothelial growth factor binding receptor Tie2 in mouse lungs.

  5. Development of a highly specific HER2 monoclonal antibody for immunohistochemistry using protein microarray chips

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qi, Lili; Zhou, Lixin; Lu, Mingmin

    HER2 is an orphan receptor tyrosine kinase of the EGFR families and is considered to be a key tumor driver gene [1]. Breast cancer and gastric cancer with HER2 amplification can be effectively treated by its neutralizing antibody, Herceptin. In clinic, Immunohistochemistry (IHC) was used as the primary screening method to diagnose HER2 amplification [2]. However, recent evidence suggested that the frequently used rabbit HER2 antibody 4B5 cross reacted with another family member HER4 [3]. IHC staining with 4B5 also indicated that there was strong non-specific cytoplasmic and nuclear signals in normal gastric mucosal cells and some gastric cancer samples.more » Using a protein lysate array which covers 85% of the human proteome, we have confirmed that the 4B5 bound to HER4 and a nuclear protein ZSCAN18 besides HER2. The non-specific binding accounts for the unexpected cytoplasmic and nuclear staining of 4B5 of normal gastric epithelium. Finally, we have developed a novel mouse HER2 monoclonal antibody UMAB36 with similar sensitivity to 4B5 but only reacted to HER2 across the 17,000 proteins on the protein chip. In 129 breast cancer and 158 gastric cancer samples, UMAB36 showed 100% sensitivity and specificity comparing to the HER2 FISH reference results with no unspecific staining in the gastric mucosa layer. Therefore, UMAB36 could provide as an alternative highly specific IHC reagent for testing HER2 amplification in gastric cancer populations. - Highlights: • HER2 antibody 4B5 cross-interacts with HER4 and ZSCAN18, which would interfere with the accuracy of IHC diagnosis of HER2. • A HER2 antibody UMAB36 has been developed with high sensitivity and specificity and can be utilized in HER2 diagnosis. • Protein lysate array is a novel strategy to screen for highly specific antibody.« less

  6. A Novel Contrast Stain for the Rapid Diagnosis of Pityriasis Versicolor: A Comparison of Chicago Sky Blue 6B Stain, Potassium Hydroxide Mount and Culture

    PubMed Central

    Lodha, Nikita; Poojary, Shital Amin

    2015-01-01

    Background: The mycological study of pityriasis versicolor is usually done by potassium hydroxide (KOH) mount and culture. However, KOH mount lacks a color contrast and requires a trained eye to interpret, while culture is difficult to perform, time consuming and has low sensitivity. Chicago Sky Blue 6B (CSB) is a new contrast stain that highlights the fungal hyphae and spores, blue against a purplish background. Aims and Objectives: This study was done to compare the utility of a novel contrast stain (CSB stain) with KOH mount and culture. Materials and Methods: Skin scrapings from the lesions of 100 clinically diagnosed cases of P. versicolor were subjected to (1) KOH mount and CSB stain for direct microscopic examination and (2) culture using Sabouraud's dextrose agar. The statistical analysis of CSB stain and culture was done using KOH mount as the reference method, as it is the most commonly performed and practical diagnostic test available for P. versicolor. An interrater reliability analysis using the Cohen's Kappa statistic was performed to determine consistency (agreement) among the different modalities. Observations and Results: Direct microscopy with CSB stain, KOH mount and mycological culture showed positive results in 98 (98%), 92 (92%) and 56 (56%) patients, respectively. Using KOH mount as the reference method, CSB stain had a sensitivity of 100% which was significantly higher than culture (60.9%). Statistically significant fair agreement was found between CSB stain and KOH mount (94% with κ=0.38, P < 0.001). Negligible agreement was found between CSB stain and culture (66%, κ=0.199, P = 0.001) as well as between KOH mount and culture (64%, κ=0.051, P = 0.107). Conclusion: CSB staining of skin scrapings is the most sensitive method for the diagnosis of pityriasis versicolor. Due to the distinct contrast provided by CSB, it is easy to perform, rapid and qualitatively superior to KOH mount. PMID:26288400

  7. Selection and application of exterior stains for wood

    Treesearch

    R. Sam Williams; William C. Feist

    1999-01-01

    Exterior stains for wood protect the wood surface from sunlight and moisture. Because stains are formulated to penetrate the wood surface, they are not prone to crack or peel as can film-forming finishes, such as paints. This publication describes the properties of stains and wood, methods for applying stains, and the expected service life of stains.

  8. Compositions for chromosome-specific staining

    DOEpatents

    Gray, Joe W.; Pinkel, Daniel

    1998-01-01

    Methods and compositions for staining based upon nucleic acid sequence that employ nucleic acid probes are provided. Said methods produce staining patterns that can be tailored for specific cytogenetic analyses. Said probes are appropriate for in situ hybridization and stain both interphase and metaphase chromosomal material with reliable signals. The nucleic acid probes are typically of a complexity greater than 50 kb, the complexity depending upon the cytogenetic application. Methods are provided to disable the hybridization capacity of shared, high copy repetitive sequences and/or remove such sequences to provide for useful contrast. Still further methods are provided to produce chromosome-specific staining reagents which are made specific to the targeted chromosomal material, which can be one or more whole chromosomes, one or more regions on one or more chromosomes, subsets of chromosomes and/or the entire genome. Probes and test kits are provided for use in tumor cytogenetics, in the detection of disease related loci, in analysis of structural abnormalities, such as translocations, and for biological dosimetry. Further, methods and prenatal test kits are provided to stain targeted chromosomal material of fetal cells, including fetal cells obtained from maternal blood. Still further, the invention provides for automated means to detect and analyse chromosomal abnormalities.

  9. Compositions for chromosome-specific staining

    DOEpatents

    Gray, J.W.; Pinkel, D.

    1998-05-26

    Methods and compositions for staining based upon nucleic acid sequence that employ nucleic acid probes are provided. The methods produce staining patterns that can be tailored for specific cytogenetic analyses. The probes are appropriate for in situ hybridization and stain both interphase and metaphase chromosomal material with reliable signals. The nucleic acid probes are typically of a complexity greater than 50 kb, the complexity depending upon the cytogenetic application. Methods are provided to disable the hybridization capacity of shared, high copy repetitive sequences and/or remove such sequences to provide for useful contrast. Still further methods are provided to produce chromosome-specific staining reagents which are made specific to the targeted chromosomal material, which can be one or more whole chromosomes, one or more regions on one or more chromosomes, subsets of chromosomes and/or the entire genome. Probes and test kits are provided for use in tumor cytogenetics, in the detection of disease related loci, in analysis of structural abnormalities, such as translocations, and for biological dosimetry. Methods and prenatal test kits are provided to stain targeted chromosomal material of fetal cells, including fetal cells obtained from maternal blood. The invention provides for automated means to detect and analyze chromosomal abnormalities. 17 figs.

  10. Crystal violet stain as a selective stain for the assessment of mitotic figures in oral epithelial dysplasia and oral squamous cell carcinoma.

    PubMed

    Jadhav, Kiran B; Ahmed Mujib, B R; Gupta, Nidhi

    2012-01-01

    Assessment of mitotic figures (MFs) is routinely practiced as prognostic indicator in oral epithelial dysplasia (OED) and oral squamous cell carcinoma (OSCC), but identification of MFs poses a problem in terms of staining characteristics. To evaluate effectiveness of crystal violet stain for staining of MFs and its comparison with hematoxylin and eosin (H and E) stain. Study sample includes archival tissues embedded in paraffin blocks diagnosed as OED (n = 30) and OSCC (n = 30). The control group comprised of tissue specimen from oral mucosa of healthy volunteers (n = 30). Two serial sections of each tissue specimen were stained separately with H and E stain and 1% crystal violet stain. The stained sections were observed under microscope for identification and counting of MFs. Data obtained was statistically analyzed by using the Man-Whitney U test. A significant increase in number of MFs was observed in OED and OSCC in comparison with normal oral mucosa. There was a highly significant increase in number of MFs in crystal violet stained tissue sections when compared with H and E stain. Metaphase is the most commonly observed phase of mitosis in crystal violet stain when compared with H and E stain for all three groups. Crystal violet stain can be considered as selective stain for mitotic figures.

  11. Differential staining of bacteria: acid fast stain.

    PubMed

    Reynolds, Jackie; Moyes, Rita B; Breakwell, Donald P

    2009-11-01

    Acid-fastness is an uncommon characteristic shared by the genera Mycobacterium (Section 10A) and Nocardia. Because of this feature, this stain is extremely helpful in identification of these bacteria. Although Gram positive, acid-fast bacteria do not take the crystal violet into the wall well, appearing very light purple rather than the deep purple of normal Gram-positive bacteria. (c) 2009 by John Wiley & Sons, Inc.

  12. Rorschach inkblot port-wine stain.

    PubMed

    Coots, N V; Elston, D M

    1997-01-01

    We present an infant born with bilaterally symmetric, anterior and posterior port-wine stains. These lesions presented a striking resemblance to Rorschach inkblots, a phenomenon not previously reported. A discussion of the case as well as a discussion of syndromes associated with port-wine stains is provided.

  13. Compact, Automated Centrifugal Slide-Staining System

    NASA Technical Reports Server (NTRS)

    Feeback, Daniel L.; Clarke, Mark S. F.

    2004-01-01

    The Directional Acceleration Vector-Driven Displacement of Fluids (DAVD-DOF) system, under development at the time of reporting the information for this article, would be a relatively compact, automated, centrifugally actuated system for staining blood smears and other microbiological samples on glass microscope slides in either a microgravitational or a normal Earth gravitational environment. The DAVD-DOF concept is a successor to the centrifuge-operated slide stainer (COSS) concept, which was reported in Slide-Staining System for Microgravity or Gravity (MSC-22949), NASA Tech Briefs, Vol. 25, No. 1 (January, 2001), page 64. The COSS includes reservoirs and a staining chamber that contains a microscope slide to which a biological sample is affixed. The staining chamber is sequentially filled with and drained of staining and related liquids from the reservoirs by use of a weighted plunger to force liquid from one reservoir to another at a constant level of hypergravity maintained in a standard swing-bucket centrifuge. In the DAVD-DOF system, a staining chamber containing a sample would also be sequentially filled and emptied, but with important differences. Instead of a simple microscope slide, one would use a special microscope slide on which would be fabricated a network of very small reservoirs and narrow channels connected to a staining chamber (see figure). Unlike in the COSS, displacement of liquid would be effected by use of the weight of the liquid itself, rather than the weight of a plunger.

  14. Identification criteria of the rare multi-flagellate Lophomonas blattarum: comparison of different staining techniques.

    PubMed

    Alam-Eldin, Yosra Hussein; Abdulaziz, Amany Mamdouh

    2015-09-01

    Bronchopulmonary lophomoniasis (BPL) is an emerging disease of potential importance. BPL is presented by non-specific clinical picture and is usually accompanied by immunosuppression. Culture of Lophomonas blattarum is difficult and its molecular diagnosis has not yet been developed. Therefore, microscopic examination of respiratory samples, e.g., bronchoalveolar lavage (BAL) or sputum, is the mainstay of BPL diagnosis. Creola bodies and ciliocytophthoria are two forms of bronchial cells which occur in chest diseases with non-specific clinical picture like that of BPL. Both forms could be misrecognized as multi-flagellates because of their motile cilia in the wet mounts and due to shape variability of L. blattarum in stained smears. The aim of the study is to compare different staining techniques for visualizing L. blattarum to improve the recognition and diagnosis of BPL, to distinguish respiratory epithelial cells from L. blattarum and to decide which stain is recommended in suspected cases of BPL. BAL samples from patients which contain L. blattarum, creola bodies, and ciliocytophthoria were collected then wet mounts were examined. The BAL samples were also stained by Papanicolaou (PAP), Giemsa, hematoxylin and eosin (H & E), trichrome, Gram, and Diff-Quik (DQ) stains. The different staining techniques were compared regarding the stain quality. In wet mounts, the ciliary movement was coordinate and synchronous while the flagellar movement was wavy and leaded to active swimming of L. blattarum. In stained slides, bronchial cells were characterized by the presence of basal nucleus and the terminal bar from which the cilia arise. Trichrome was the best stain in demonstration of cellular details of L. blattarum. H & E, PAP, and Giemsa stains showed good quality of stains. Gram and DQ stains showed only pale hues of L. blattarum. We recommended adding Wheatley's trichrome staining to the differential diagnosis workup of cases of non-specific chest infections

  15. The comparison of pyrosequencing molecular Gram stain, culture, and conventional Gram stain for diagnosing orthopaedic infections.

    PubMed

    Kobayashi, Naomi; Bauer, Thomas W; Tuohy, Marion J; Lieberman, Isador H; Krebs, Viktor; Togawa, Daisuke; Fujishiro, Takaaki; Procop, Gary W

    2006-08-01

    We have developed a combined real-time PCR and pyrosequencing assay that successfully differentiated the vast majority of gram-positive and gram-negative bacteria when bacterial isolates were tested. The purpose of this study was to evaluate this assay on clinical specimens obtained from orthopedic surgeries, and to prospectively compare the results of "molecular Gram stain" with culture and conventional direct Gram stain. Forty-five surgical specimens were obtained from patients who underwent orthopedic surgery procedures. The DNA was extracted and a set of broad-range PCR primers that targeted a part of the 16S rDNA gene was used for pan-bacterial PCR. The amplicons were submitted for pyrosequencing and the resulting molecular Gram stain characteristics were recorded. Culture and direct Gram staining were performed using standard methods for all cases. Surgical specimens were reviewed histologically for all cases that had a discrepancy between culture and molecular results. There was an 86.7% (39/45) agreement between the traditional and molecular methods. In 12/14 (85.7%) culture-proven cases of bacterial infection, molecular Gram stain characteristics were in agreement with the culture results, while the conventional Gram stain result was in agreement only for five cases (35.7%). In the 31 culture negative cases, 27 cases were also PCR negative, whereas 4 were PCR positive. Three of these were characterized as gram negative and one as gram positive by this molecular method. Molecular determination of the Gram stain characteristics of bacteria that cause orthopedic infections may be achieved, in most instances, by this method. Further studies are necessary to understand the clinical importance of PCR-positive/culture-negative results.

  16. A Flow-Cytometric Gram-Staining Technique for Milk-Associated Bacteria

    PubMed Central

    Holm, Claus; Jespersen, Lene

    2003-01-01

    A Gram-staining technique combining staining with two fluorescent stains, Oregon Green-conjugated wheat germ agglutinin (WGA) and hexidium iodide (HI) followed by flow-cytometric detection is described. WGA stains gram-positive bacteria while HI binds to the DNA of all bacteria after permeabilization by EDTA and incubation at 50°C for 15 min. For WGA to bind to gram-positive bacteria, a 3 M potassium chloride solution was found to give the highest fluorescence intensity. A total of 12 strains representing some of the predominant bacterial species in bulk tank milk and mixtures of these were stained and analyzed by flow cytometry. Overall, the staining method showed a clear differentiation between gram-positive and gram-negative bacterial populations. For stationary-stage cultures of seven gram-positive bacteria and five gram-negative bacteria, an average of 99% of the cells were correctly interpreted. The method was only slightly influenced by the growth phase of the bacteria or conditions such as freezing at −18°C for 24 h. For any of these conditions, an average of at least 95% of the cells were correctly interpreted. When stationary-stage cultures were stored at 5°C for 14 days, an average of 86% of the cells were correctly interpreted. The Gram-staining technique was applied to the flow cytometry analysis of bulk tank milk inoculated with Staphylococcus aureus and Escherichia coli. These results demonstrate that the technique is suitable for analyzing milk samples without precultivation. PMID:12732558

  17. Photodynamic therapy for port wine stains

    NASA Astrophysics Data System (ADS)

    Li, Junheng

    1998-08-01

    Therapies for port wine stains including conventional laser irradiation usually cause unacceptable scarring or obtain poor effect. Pulsed dye laser has better approach, but only few patients obtain complete fading after multiple laser treatment. Because port wine stain is a congenital vasculopathy consisting of an abnormal network of capillaries in the upper dermis with an overlying normal epidermis and the researchers found that tumor blood vessels were occluded accompanying the necrosis of the tumor after PDT. It is though to be the effect primarily by thrombus formation in vessels and shut down of the blood supply to the tumor as well as direct tumor cells kill. The author and his colleagues started a series of animal and clinical studies since 1991 about photodynamic therapy for port wine stains and they established the method of PDT for PWS. An experimental study showed that Hpd appeared rapidly within the human vascular endothelial cells in culture fluid. Animal study using chicken combs as PWS models treated by PDT revealed the possibility of selective destruction of the malformative vasculature in PWS. The clinical studies of over 1700 cases proved that PWS can be cured without scar formation by PDT because there is no thermal effect involved. No relapse was found within a maximum follow-up of seven years. The differences and mechanism between the treatments of PDT and conventional lasers are discussed.

  18. Morphological characteristics of developmental stages of Acanthamoeba and Naegleria species before and after staining by various techniques.

    PubMed

    Ithoi, Init; Ahmad, Arine-Fadzlun; Mak, J W; Nissapatorn, Veeranoot; Lau, Yee-Ling; Mahmud, Rohela

    2011-11-01

    Seven stains were studied to determine the best color and contrast for staining the developmental stages of free living pathogenic Acanthamoeba and Naegleria species. The acid-fast bacilli stain (AFB) produced a blue color without contrast; trichrome-eosin and modified Field's showed various color contrasts; Giemsa, iron-hematoxylin, modified AFB and Gram produced only one color which distinguished the nucleus, nucleolus, cytoplasm, food- and water-vacuoles. The motile organs (acanthopodia, pseudopodia, lobopodia and flagella) were also clearly differentiated but produced a similar color as the cytoplasm. These motile organelles were first induced by incubating at 37 degrees C for at least 15 minutes and then fixing with methanol in order to preserve the protruding morphology prior to staining. The trichrome-eosin and iron-hematoxylin stains showed good color contrast for detecting all three stages, the trophozoite, cyst and flagellate; Giemsa and Gram stained the trophozoite and flagellate stages; the modified Field's and modified AFB stains stained only the trophozoite stage. Depending on the purpose, all these stains (except the AFB stain) can be used to identify the developmental stages of Acanthamoeba and Naegleria for clinical, epidemiological or public health use.

  19. Tumor containing fragment number influences immunohistochemistry positive rate of HER2 in biopsy specimens of gastric cancer.

    PubMed

    Xu, Chen; Liu, Yalan; Ge, Xiaowen; Jiang, Dongxian; Zhang, Ying; Ji, Yuan; Hou, Jun; Huang, Jie; Su, Jieakesu; Zeng, Haiying; Qin, Jing; Hou, Yingyong

    2017-05-26

    HER2 assessment in biopsy specimens of gastric cancer (GC) is challenging because of the intratumoral heterogeneity. False negative results may be get because of limited biopsy material. The aim of this study is to explore how tumor-containing fragment number and biopsy specimen number affect HER2 immunohistochemistry (IHC) positive rate. Eight hundred and ninety biopsy specimens and 459 paired resected specimens were collected. IHC staining of HER2 was performed. HER2 IHC positive (scored 3+) rate was compared based on tumor-containing fragment number, biopsy specimen number, average size and tumor tissue proportion of tumor-containing fragments. The positive predictability of biopsy specimens to resected specimens was analyzed based on tumor fragment number. HER2 IHC positive rates were 2.0, 3.5, 7.0, 13.2, 17.1, and 15.9% when tumor fragment numbers were 1, 2, 3, 4, 5 and 6 respectively. The rate rose with the increase of tumor fragment number (P = 0.004). ROC curve analysis showed that biopsy specimens exhibited positive predictability when tumor fragment number reached 3, but showed better performance when the number was ≥4 (P < 0.05). After fragment number reached 4, no statistic differences were reached in either HER2 IHC positive rate or positive predictability with further increase of the number (P > 0.05). HER2 IHC positive rate was not associated with biopsy number (P = 0.127), average size of tumor fragments (P = 0.397), and tumor tissue proportion of tumor fragments (P = 0.825) directly. The number of tumor-containing fragments influences HER2 IHC positive (scored 3+) rate. Greater than or equal to 4 (≥4) tumor fragments give better results in the positive rate as well as positive predictability. We recommend the number of tumor containing fragments be described in the HER2 IHC pathology reports for clinical reference in endoscopic biopsy specimens of GC.

  20. Best practices recommendations in the application of immunohistochemistry in testicular tumors: report from the International Society of Urological Pathology consensus conference.

    PubMed

    Ulbright, Thomas M; Tickoo, Satish K; Berney, Daniel M; Srigley, John R

    2014-08-01

    The judicious use of immunostains can be of significant diagnostic assistance in the interpretation of testicular neoplasms when the light microscopic features are ambiguous. A limited differential diagnosis by traditional morphology is required for the effective use of immunohistochemistry (IHC); otherwise, the inevitable occurrence of exceptions to anticipated patterns will lead to "immunoconfusion." The diagnosis of tumors in the germ cell lineage, the great majority of primary tumors of the testis, has been considerably facilitated over the past decade by IHC directed at developmentally important nuclear transcription factors, including OCT4, SALL4, SOX2, and SOX17, that are mostly restricted to certain tumor histotypes. In conjunction with other markers, a specific diagnosis can be achieved in most instances through a panel of 3 or 4 immunostains and often fewer. IHC among tumors in the sex cord-stromal group may produce a significant proportion of false-negative cases until more sensitive and equally specific markers are validated. The negativity of these tumors for the IHC stains used for germ cell tumors is key in the important distinction of neoplasms in these 2 general categories. In this review, the International Society of Urological Pathologists (ISUP) provides diagnostic guidelines in the form of algorithms to assist practicing pathologists confronting a differential diagnostic question concerning a testicular neoplasm. The goal of ISUP is to anticipate commonly encountered differential diagnoses and recommend an efficient and limited pattern of IHC stains to resolve the question.

  1. Fluorescein-labeled β-Glucosidase as a Bacterial Stain

    PubMed Central

    Pital, Abe; Janowitz, Sheldon L.; Hudak, Charles E.; Lewis, Evelyn E.

    1967-01-01

    Fluorescein isothiocyanate-labeled β-glucosidase was used as a simple staining reagent with selected gram-positive and gram-negative organisms. Staining in situ appeared to be dependent on the presence of accessible glycosidic-type linkages in the bacterial cell wall. Extensive wall damage or lysis did not occur when stained cells were suspended in washing and mounting solutions. The apparent specificity of labeled enzyme for wall substance was tested by blocking reactions, staining of isolated cell walls, and failure to stain substances lacking appropriate glycosidic linkages. Severe cell wall lesions were produced after prolonged contact with labeled enzyme, and this phenomenon may also be related to staining specificity. Gram-negative organisms and spores were poorly stained unless protected glycopeptide substrate was previously exposed by treatment of cells with thioglycolic acid or dilute alkaline sodium hypochlorite solution. A potential for staining tissues and cell lines may also exist. Some possible applications of labeled enzymes are briefly discussed. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 PMID:4169543

  2. Use of the gram stain in microbiology.

    PubMed

    Beveridge, T J

    2001-05-01

    The Gram stain differentiates bacteria into two fundamental varieties of cells. Bacteria that retain the initial crystal violet stain (purple) are said to be "gram-positive," whereas those that are decolorized and stain red with carbol fuchsin (or safranin) are said to be "gram-negative." This staining response is based on the chemical and structural makeup of the cell walls of both varieties of bacteria. Gram-positives have a thick, relatively impermeable wall that resists decolorization and is composed of peptidoglycan and secondary polymers. Gram-negatives have a thin peptidoglycan layer plus an overlying lipid-protein bilayer known as the outer membrane, which can be disrupted by decolorization. Some bacteria have walls of intermediate structure and, although they are officially classified as gram-positives because of their linage, they stain in a variable manner. One prokaryote domain, the Archaea, have such variability of wall structure that the Gram stain is not a useful differentiating tool.

  3. Aureobasidium pullulans morphology: two adapted polysaccharide stains.

    PubMed

    Oller, Anna R

    2005-12-01

    Morphological stages of Aureobasidium pullulans were investigated utilizing different media ingredients and were visualized by bright-field microscopy. A polysaccharide stain was developed to stain chlamydospores, cell walls, hyphae, and conidia, since current staining techniques do not reveal subcellular details to identify fungi, especially those that exhibit polysaccharide secretions.

  4. Comparison of algorithms for blood stain detection applied to forensic hyperspectral imagery

    NASA Astrophysics Data System (ADS)

    Yang, Jie; Messinger, David W.; Mathew, Jobin J.; Dube, Roger R.

    2016-05-01

    Blood stains are among the most important types of evidence for forensic investigation. They contain valuable DNA information, and the pattern of the stains can suggest specifics about the nature of the violence that transpired at the scene. Early detection of blood stains is particularly important since the blood reacts physically and chemically with air and materials over time. Accurate identification of blood remnants, including regions that might have been intentionally cleaned, is an important aspect of forensic investigation. Hyperspectral imaging might be a potential method to detect blood stains because it is non-contact and provides substantial spectral information that can be used to identify regions in a scene with trace amounts of blood. The potential complexity of scenes in which such vast violence occurs can be high when the range of scene material types and conditions containing blood stains at a crime scene are considered. Some stains are hard to detect by the unaided eye, especially if a conscious effort to clean the scene has occurred (we refer to these as "latent" blood stains). In this paper we present the initial results of a study of the use of hyperspectral imaging algorithms for blood detection in complex scenes. We describe a hyperspectral imaging system which generates images covering 400 nm - 700 nm visible range with a spectral resolution of 10 nm. Three image sets of 31 wavelength bands were generated using this camera for a simulated indoor crime scene in which blood stains were placed on a T-shirt and walls. To detect blood stains in the scene, Principal Component Analysis (PCA), Subspace Reed Xiaoli Detection (SRXD), and Topological Anomaly Detection (TAD) algorithms were used. Comparison of the three hyperspectral image analysis techniques shows that TAD is most suitable for detecting blood stains and discovering latent blood stains.

  5. Multicenter Assessment of Gram Stain Error Rates

    PubMed Central

    Balada-Llasat, Joan-Miquel; Harrington, Amanda; Cavagnolo, Robert

    2016-01-01

    Gram stains remain the cornerstone of diagnostic testing in the microbiology laboratory for the guidance of empirical treatment prior to availability of culture results. Incorrectly interpreted Gram stains may adversely impact patient care, and yet there are no comprehensive studies that have evaluated the reliability of the technique and there are no established standards for performance. In this study, clinical microbiology laboratories at four major tertiary medical care centers evaluated Gram stain error rates across all nonblood specimen types by using standardized criteria. The study focused on several factors that primarily contribute to errors in the process, including poor specimen quality, smear preparation, and interpretation of the smears. The number of specimens during the evaluation period ranged from 976 to 1,864 specimens per site, and there were a total of 6,115 specimens. Gram stain results were discrepant from culture for 5% of all specimens. Fifty-eight percent of discrepant results were specimens with no organisms reported on Gram stain but significant growth on culture, while 42% of discrepant results had reported organisms on Gram stain that were not recovered in culture. Upon review of available slides, 24% (63/263) of discrepant results were due to reader error, which varied significantly based on site (9% to 45%). The Gram stain error rate also varied between sites, ranging from 0.4% to 2.7%. The data demonstrate a significant variability between laboratories in Gram stain performance and affirm the need for ongoing quality assessment by laboratories. Standardized monitoring of Gram stains is an essential quality control tool for laboratories and is necessary for the establishment of a quality benchmark across laboratories. PMID:26888900

  6. Characterization and clinical validation of MCM2 and TOP2A monoclonal antibodies in the BD ProEx™ C assay: An immunoassay which detects aberrant S-phase induction in cervical tissue.

    PubMed

    Dixon, Eric P; King, Lorraine M; Nelson, Ramona; Simkins, Stephen G; Knapp, Steven L; Brough, George H; Lenz, Karen L; Henderson, Dorian T; Whitehead, Clark M; Hessling, Janice; Brown, Charlotte A; Malinowski, Douglas P

    2017-03-01

    The Papanicolaou (Pap) screen has been successful in reducing cervical cancer; but exhibits low sensitivity when detecting cervical dysplasia. Use of molecular biomarkers in Pap tests may improve diagnostic accuracy. Monoclonal antibodies to Minichromosome Maintenance Protein 2 (MCM2) and DNA Topoisomerase II α (TOP2A) were selected for use in IHC based on their ability to differentiate normal from diseased cervical tissues in tissue microarrays. Enhanced Green Fluorescent Protein Western blot analysis was used to help identify binding epitopes specific to MCM2 and TOP2A antibody clones. Antibody affinity was determined by solution phase affinity measurement and immunohistochemistry was performed using high affinity MCM2 or TOP2A antibodies on serial histological sections. Antibody clones to MCM2 and TOP2A clones were selected based on their ability to detect over expression in abnormal cervical epithelia. In IHC, MCM2-27C5.6 and MCM2-26H6.19 demonstrated superior staining in abnormal cervical tissue over the MCM2-CRCT2.1 antibody. A combination of MCM2 and TOP2A antibodies showed greater staining when compared to staining with any of the antibodies alone on serial histological sections. Distinct linear epitopes were elucidated for each of the MCM2 and TOP2A clones. Affinity values (Kd) for MCM2 or TOP2A antibodies had a similar range. In a research study, the MCM2 and TOP2A (BD ProEx™ C) antibody cocktail showed increased epithelia staining with increasing dysplasia. The use of BD ProEx™ C in combination with H&E staining enhanced immunohistochemical discrimination of dysplastic and non-dysplastic FFPE cervical tissue specimens. BD ProEx™ C containing MCM2 and TOP2A antibodies showed strong specific nuclear staining that correlated with increased dysplasia and lesion severity. Enhanced performance of the antibodies was linked to their unique topography recognition. BD ProEx™ C incorporates antibodies that enhance detection of CIN2+ cervical disease

  7. Osteoinduction by Ca-P biomaterials implanted into the muscles of mice*

    PubMed Central

    Yang, Rui-na; Ye, Feng; Cheng, Li-jia; Wang, Jin-jing; Lu, Xiao-feng; Shi, Yu-jun; Fan, Hong-song; Zhang, Xing-dong; Bu, Hong

    2011-01-01

    The osteoinduction of porous biphasic calcium phosphate ceramics (BCP) has been widely reported and documented, but little research has been performed on rodent animals, e.g., mice. In this study, we report osteoinduction in a mouse model. Thirty mice were divided into two groups. BCP materials (Sample A) and control ceramics (Sample B) were implanted into the leg muscle, respectively. Five mice in each group were killed at 15, 30, and 45 d after surgery. Sample A and Sample B were harvested and used for hematoxylin and eosin (HE) staining, immunohistochemistry (IHC) staining, and Alizarin Red S staining to check bone formation in the biomaterials. Histological analysis showed that no bone tissue was formed 15 d after implantation (0/5) in either of the two groups. Newly-formed bone tissues were observed in Sample A at 30 d (5/5) and 45 d (5/5) after implantation; the average amounts of newly-formed bone tissues were approximately 5.2% and 8.6%, respectively. However, we did not see any bone tissue in Sample B until 45 d after implantation. Bone-related molecular makers such as bone morphogenesis protein-2 (BMP-2), collagen type I, and osteopontin were detected by IHC staining in Sample A 30 d after implantation. In addition, the newly-formed bone was also confirmed by Alizarin Red S staining. Because this is the report of osteoinduction in the rodent animal on which all the biotechnologies were available, our results may contribute to further mechanism research. PMID:21726066

  8. Automated single-slide staining device. [in clinical bacteriology

    NASA Technical Reports Server (NTRS)

    Wilkins, J. R.; Mills, S. M.

    1975-01-01

    An automatic single-slide Gram staining device is described. A timer-actuated solenoid controls the dispensing of gentian violet, Gram iodine solution, decolorizer, and 1% aqueous safranin in proper sequence and for the time required for optimum staining. The amount of stain or reagent delivered is controlled by means of stopcocks below each solenoid. Used stains and reagents can be flushed automatically or manually. Smears Gram stained automatically are equal in quality to those prepared manually. The time to complete one Gram cycle is 4.80 min.

  9. Confocal mosaicing microscopy of human skin ex vivo: spectral analysis for digital staining to simulate histology-like appearance

    PubMed Central

    Bini, Jason; Spain, James; Nehal, Kishwer; Hazelwood, Vikki; DiMarzio, Charles; Rajadhyaksha, Milind

    2011-01-01

    Confocal mosaicing microscopy enables rapid imaging of large areas of fresh tissue, without the processing that is necessary for conventional histology. Mosaicing may offer a means to perform rapid histology at the bedside. A possible barrier toward clinical acceptance is that the mosaics are based on a single mode of grayscale contrast and appear black and white, whereas histology is based on two stains (hematoxylin for nuclei, eosin for cellular cytoplasm and dermis) and appears purple and pink. Toward addressing this barrier, we report advances in digital staining: fluorescence mosaics that show only nuclei, are digitally stained purple and overlaid on reflectance mosaics, which show only cellular cytoplasm and dermis, and are digitally stained pink. With digital staining, the appearance of confocal mosaics mimics the appearance of histology. Using multispectral analysis and color matching functions, red, green, and blue (RGB) components of hematoxylin and eosin stains in tissue were determined. The resulting RGB components were then applied in a linear algorithm to transform fluorescence and reflectance contrast in confocal mosaics to the absorbance contrast seen in pathology. Optimization of staining with acridine orange showed improved quality of digitally stained mosaics, with good correlation to the corresponding histology. PMID:21806269

  10. Confocal mosaicing microscopy of human skin ex vivo: spectral analysis for digital staining to simulate histology-like appearance

    NASA Astrophysics Data System (ADS)

    Bini, Jason; Spain, James; Nehal, Kishwer; Hazelwood, Vikki; Dimarzio, Charles; Rajadhyaksha, Milind

    2011-07-01

    Confocal mosaicing microscopy enables rapid imaging of large areas of fresh tissue, without the processing that is necessary for conventional histology. Mosaicing may offer a means to perform rapid histology at the bedside. A possible barrier toward clinical acceptance is that the mosaics are based on a single mode of grayscale contrast and appear black and white, whereas histology is based on two stains (hematoxylin for nuclei, eosin for cellular cytoplasm and dermis) and appears purple and pink. Toward addressing this barrier, we report advances in digital staining: fluorescence mosaics that show only nuclei, are digitally stained purple and overlaid on reflectance mosaics, which show only cellular cytoplasm and dermis, and are digitally stained pink. With digital staining, the appearance of confocal mosaics mimics the appearance of histology. Using multispectral analysis and color matching functions, red, green, and blue (RGB) components of hematoxylin and eosin stains in tissue were determined. The resulting RGB components were then applied in a linear algorithm to transform fluorescence and reflectance contrast in confocal mosaics to the absorbance contrast seen in pathology. Optimization of staining with acridine orange showed improved quality of digitally stained mosaics, with good correlation to the corresponding histology.

  11. Multicenter Assessment of Gram Stain Error Rates.

    PubMed

    Samuel, Linoj P; Balada-Llasat, Joan-Miquel; Harrington, Amanda; Cavagnolo, Robert

    2016-06-01

    Gram stains remain the cornerstone of diagnostic testing in the microbiology laboratory for the guidance of empirical treatment prior to availability of culture results. Incorrectly interpreted Gram stains may adversely impact patient care, and yet there are no comprehensive studies that have evaluated the reliability of the technique and there are no established standards for performance. In this study, clinical microbiology laboratories at four major tertiary medical care centers evaluated Gram stain error rates across all nonblood specimen types by using standardized criteria. The study focused on several factors that primarily contribute to errors in the process, including poor specimen quality, smear preparation, and interpretation of the smears. The number of specimens during the evaluation period ranged from 976 to 1,864 specimens per site, and there were a total of 6,115 specimens. Gram stain results were discrepant from culture for 5% of all specimens. Fifty-eight percent of discrepant results were specimens with no organisms reported on Gram stain but significant growth on culture, while 42% of discrepant results had reported organisms on Gram stain that were not recovered in culture. Upon review of available slides, 24% (63/263) of discrepant results were due to reader error, which varied significantly based on site (9% to 45%). The Gram stain error rate also varied between sites, ranging from 0.4% to 2.7%. The data demonstrate a significant variability between laboratories in Gram stain performance and affirm the need for ongoing quality assessment by laboratories. Standardized monitoring of Gram stains is an essential quality control tool for laboratories and is necessary for the establishment of a quality benchmark across laboratories. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  12. Say goodbye to coffee stains

    NASA Astrophysics Data System (ADS)

    Burak Eral, H.; van den Ende, Dirk; Mugele, Frieder

    2012-04-01

    Discussing ideas over a mug of coffee or tea is the lifeblood of science, but have you ever thought about the stains that can be inadvertently left behind? H Burak Eral, Dirk van den Ende and Frieder Mugele explain how these stains, which can be a major annoyance in some biology techniques, can be altered for the better using a technique called electrowetting.

  13. Evaluation of lipid oxidative stress status and inflammation in atopic ocular surface disease

    PubMed Central

    Wakamatsu, Tais H.; Ayako, Igarashi; Takano, Yoji; Matsumoto, Yukihiro; Ibrahim, Osama M.A.; Okada, Naoko; Satake, Yoshiyuki; Fukagawa, Kazumi; Shimazaki, Jun; Tsubota, Kazuo; Fujishima, Hiroshi

    2010-01-01

    Background Although the oxidative stress status in atopic skin disease has been reported to be elevated, there are still no studies related to the status of oxidative stress in atopic ocular surface disease. The purpose of this study was to evaluate the ocular surface lipid oxidative stress status and inflammation in atopic keratoconjunctivitis (AKC) patients and normal subjects. Methods Twenty eight eyes of 14 patients (9 males, 5 females) with AKC and 18 eyes of 9 age and sex matched (4 males and 5 females) normal healthy controls were examined in this prospective study. The severity of atopic dermatitis (AD) was scored by the SCORing Atopic Dermatitis (SCORAD) index. All subjects underwent Schirmer test, tear film break up time (BUT), fluorescein/Rose Bengal stainings, tear collection, and brush cytology from the upper palpebral conjunctiva. The brush cytology samples were stained with Diff-Quik for differentiation of inflammatory cells and immunohistochemistry (IHC) staining with HEL (hexanoyl-lysine) and 4-HNE (4-hydroxy-2-nonenal) to study lipid oxidation. HEL and cytokine (interleukin-4 (IL-4), interleukin-5 (IL-5), interleukin-10 (IL-10), tumor necrosis factor-alpha (TNF-α), interferon-gamma (IFN-γ)) levels were measured by enzyme-linked immunosorbent assay (ELISA) from tear samples of AKC patients and control subjects. Toluidine Blue and IHC staining with HEL, 4-HNE and cluster of differentiation 45 (CD45) were performed on papillary samples of AKC patients. This study was conducted in compliance with the “Declaration of Helsinki.” Results The tear stability and vital staining scores were significantly worse in eyes of AKC patients (p<0.05) compared to the controls. Inflammatory cells and positively stained conjunctival epithelial cells for HEL and 4-HNE showed a significant elevation in brush cytology samples of AKC patients. Significantly higher levels of HEL and cytokines were detected in tears of AKC patients compared to controls. Papillary

  14. Stain-etched porous silicon nanostructures for multicrystalline silicon-based solar cells

    NASA Astrophysics Data System (ADS)

    Ben Rabha, M.; Hajji, M.; Belhadj Mohamed, S.; Hajjaji, A.; Gaidi, M.; Ezzaouia, H.; Bessais, B.

    2012-02-01

    In this paper, we study the optical, optoelectronic and photoluminescence properties of stain-etched porous silicon nanostructures obtained with different etching times. Special attention is given to the use of the stain-etched PS as an antireflection coating as well as for surface passivating capabilities. The surface morphology has been analyzed by scanning electron microscopy. The evolution of the Si-O and Si-H absorption bands was analyzed by Fourier transform infrared spectrometry before and after PS treatment. Results show that stain etching of the silicon surface drops the total reflectivity to about 7% in the 400-1100 nm wavelength range and the minority carrier lifetime enhances to about 48 μs.

  15. Double-Staining Method for Differentiation of Morphological Changes and Membrane Integrity of Campylobacter coli Cells

    PubMed Central

    Alonso, Jose L.; Mascellaro, Salvatore; Moreno, Yolanda; Ferrús, María A.; Hernández, Javier

    2002-01-01

    We developed a double-staining procedure involving NanoOrange dye (Molecular Probes, Eugene, Oreg.) and membrane integrity stains (LIVE/DEAD BacLight kit; Molecular Probes) to show the morphological and membrane integrity changes of Campylobacter coli cells during growth. The conversion from a spiral to a coccoid morphology via intermediary forms and the membrane integrity changes of the C. coli cells can be detected with the double-staining procedure. Our data indicate that young or actively growing cells are mainly spiral shaped (green-stained cells), but older cells undergo a degenerative change to coccoid forms (red-stained cells). Club-shaped transition cell forms were observed with NanoOrange stain. Chlorinated drinking water affected the viability but not the morphology of C. coli cells. PMID:12324366

  16. Comparison of Histochemical Staining Methods and Correlation with Transient Elastography in Acute Hepatitis.

    PubMed

    Cabibi, Daniela; Calvaruso, Vincenza; Giuffrida, Letizia; Ingrao, Sabrina; Balsamo, Laura; Giannone, Antonino Giulio; Petta, Salvatore; Di Marco, Vito

    2015-03-06

    To compare Masson's trichrome (MT), Sirius red (SR) and orcein staining in acute hepatitis (AH) and to correlate them with transient elastography (TE), a noninvasive method to assess hepatic fibrosis. We evaluated liver stiffness by TE in a cohort of 34 consecutive patients and assessed MT-, SR- and orcein-stained biopsies using the METAVIR scoring system and digital image analysis (DIA). MT and SR both showed severe fibrosis (stage III-IV, DIA = 12.7%). Orcein showed absent or mild fibrosis (stage 0-II, DIA = 4.4%; p < 0.05). In 29/34 cases (85%), stiffness values were >12.5 kPa, in keeping with SR/MT but not with orcein results. Even though in AH true elastic fibrosis is typically absent or mild, TE shows elevated stiffness values, in keeping with SR/MT evaluations. If not properly evaluated in the clinical context, these results would lead to an overestimation of fibrosis. Orcein is the only staining able to evidence the absence of true elastic fibrosis, which is a typical feature of AH. This is the first study comparing different staining procedures performed on AH biopsies by DIA versus TE. © 2015 S. Karger AG, Basel.

  17. CGP stain: An inexpensive, odorless, rapid, sensitive, and in principle in vitro methylation-free Coomassie Brilliant Blue stain.

    PubMed

    Yasumitsu, Hidetaro; Ozeki, Yasuhiro; Kawsar, Sarkar M A; Toda, Tosifusa; Kanaly, Robert

    2010-11-01

    Coomassie Brilliant Blue (CBB) protein stains are inexpensive but detect proteins at only at microgram levels. Because of acetic acid and methanol, they cause skin irritation and reduce work motivation by malodor. Recent mass spectrometric (MS) analyses demonstrated that nanogram-sensitive colloidal CBB staining resulted in in vitro methylations of proteins. We propose a rapid, inexpensive, sensitive, odorless, less harsh, and in vitro methylation-free CBB stain. CGP uses three components: citric acid, CBB G-250, and polyvinylpyrrolidone. CGP detects proteins at 12ng within 45min, and because it is nonalcohol, in principle in vitro methylation would be eliminated. Indeed, MS analysis of CGP-stained bands confirmed a lack of methylation. 2010 Elsevier Inc. All rights reserved.

  18. Efficacy of evaluation of rooster sperm morphology using different staining methods.

    PubMed

    Lukaszewicz, E; Jerysz, A; Partyka, A; Siudzińska, A

    2008-12-01

    This work focused on inexpensive methods of evaluation fowl sperm morphology, based on eosin-nigrosin smears, which can determine disorders in spermatogenesis and can be recommended for evaluating the fertilising potency and selecting males in flocks reproduced by artificial insemination. Four fowl breeds (Black Minorca, Italian Partridge, Forwerk and Greenleg Partridge) were used to determine the efficacy of sperm morphology evaluation using four eosin-nigrosin staining methods (according to Blom, Bakst and Cecil, Morisson, Jaśkowski) and three examiners of different experience (high, medium, novice). There were significant (P< or = 0.01) differences in sperm morphology between Blom's staining method and those of Bakst and Cecil, Morisson or Jaśkowski, irrespective of fowl breed and examiners experience. Blom stain caused sperm head swelling and showed a drastic reduction in the proportion of live spermatozoa with normal morphology. The staining method had a greater influence on sperm morphology evaluation than the experience of the examiners.

  19. [Myofibroma/myofibromatosis: a clinicopathologic analysis of 9 cases].

    PubMed

    Fu, Y; Guan, W Y; Wu, H Y; Wu, H Y; Fan, Z W; Ye, Q; Meng, F Q

    2018-01-08

    Objective: To investigate the clinical and histological features, diagnosis and differential diagnosis of myofibroma/myofibromatosis. Methods: The clinical data and pathology features of nine cases of myofibroma/myofibromatosis were collected from August 2011 to November 2016 in Affiliated Drum Tower Hospital, Nanjing University Medical School and Children's Hospital of Nanjing Medical University. Immunohistochemistry(IHC), PDGFRB molecular analysis and ETV6-NTRK3 gene fusion were performed and relevant literature reviewed. Results: There were 7 males and 2 females, with age ranging from 3 days to 18 years (mean 5 years). The tumors were located in head and neck (eight cases) and trunk (one case). Clinically, the tumors presented as freely movable nodules. Microscopically, they appeared biphasic with alternating light- and dark-staining areas. The light-staining area consisted mainly of plump myoid spindle cells with eosinophilic cytoplasm arranged in nodules, short fascicles, or whorls.The dark-staining area was composed of round or polygonal cells with slightly hyperchromatic nuclei or small spindle cells arranged around a distinct hemangiopericytoma-like vascular pattern. IHC showed the tumor cells in the light-staining area were strongly positive for vimentin and SMA, while cells in dark-staining area were strongly positive for vimentin, and weakly for SMA. Tumor cells were negative for desmin, S-100 protein, h-Caldesmon, CD34 and STAT6. Analysis of PDGFRB mutations was performed in seven cases. Two cases showed 12 exon point mutation c. 1681 c>T(p.R561C), one case showed 14 exon point mutation c. 1998C>G (p.N666K). ETV6-NTRK3 gene fusion was not detected by fluorescence in situ hybridization in four patients under three years old. All cases were followed for 6 to 68 months, with two recurrences. Conclusions: Myofibroma/myofibromatosis is an uncommon benign myofibroblastic tumor of infancy and childhood. The tumor can appear biphasic, and may show PDGFRB point

  20. Propidium iodide (PI) stains Nissl bodies and may serve as a quick marker for total neuronal cell count.

    PubMed

    Niu, Junfei; Li, Chunman; Wu, Haihui; Feng, Xianling; Su, Qingning; Li, Shihe; Zhang, Lihong; Yew, David Tai Wai; Cho, Eric Yu Pang; Sha, Ou

    2015-03-01

    Propidium iodide (PI) reacts with both DNA and RNA and is a commonly used fluorescent reagent for nucleic acid staining. The aim of the study was to compare the cellular staining patterns of PI with that of Nissl staining in rat nervous tissues and to report a modified staining method that selectively labels Nissl bodies in neurons. Cryosections and paraffin sections of different tissues of normal Sprague-Dawley rats, including trigeminal ganglia, dorsal root ganglia, spinal cord, liver, and small intestine, were stained by either PI or the hematoxylin and eosin method. Some sections were treated with RNase or DNase before the above staining, and some were double stained with PI and a Nissl stain. The sections were observed by light, fluorescence or confocal microscopy. Results showed strong PI signals detected as patterns of granules in the neuronal cytoplasm of all nervous tissues, whereas the staining of neuronal nuclei was weaker. In contrast, nuclei of neuroglial cells were strongly stained by PI, while the cytoplasm was not obviously stained. Pretreatment of the neural tissue with RNase abolished the PI signals. Furthermore, the PI positive granules in neuronal cytoplasm co-localized with Nissl bodies stained by the fluorescent Nissl stain. When the tissue was pretreated with DNase, PI only stained the cytoplasmic granules of neurons, but not that of glial cells. Our results show that PI stains Nissl bodies and may serve as an economical and convenient neuron marker for neuronal cell counting when specific neural markers such as antibodies are not readily available. Copyright © 2015. Published by Elsevier GmbH.

  1. Port-Wine Stains

    MedlinePlus

    ... or surgery. Port-wine stains can also develop grape-like growths of small blood vessels called vascular ... another part of themselves — like their height or eye color. It's also important, emotionally, for kids to ...

  2. Use of Oil Red O stain in the cytologic diagnosis of canine liposarcoma.

    PubMed

    Masserdotti, Carlo; Bonfanti, Ugo; De Lorenzi, Davide; Ottolini, Nicola

    2006-03-01

    Oil Red O, a stain commonly used to demonstrate lipid in frozen tissue, also may be used to stain air-dried cytologic specimens. The purpose of this study was to prospectively evaluate the value of Oil Red O in identifying lipid to aid in the differentiation of liposarcomas from other types of sarcoma. Twelve tumor specimens from dogs were evaluated. The tumors were included in the study if initial cytologic evaluation indicated a sarcoma, and if histologic confirmation was available. Oil Red O was applied to all cytologic specimens. Tumor specimens were diagnosed histologically as liposarcoma (3 well-differentiated, 1 pleomorphic), hemangiopericytoma (n = 3), fibrosarcoma (n = 3), malignant fibrous histiocytoma (n = 1), and undifferentiated sarcoma (n = 1). Cytologic specimens from all liposarcomas showed strong positive staining of cytoplasmic vacuoles for lipid. Specimens from other sarcomas stained negative for Oil Red O, with the exception of weak, irregular positive staining in 1 hemangiopericytoma. Our results suggest that Oil Red O staining may be an easy, inexpensive, and useful diagnostic tool for the differentiation of liposarcoma from other mesenchymal neoplasms.

  3. Indocyanine green staining facilitates detection of bleb leakage during trabeculectomy.

    PubMed

    Okazaki, Teruhiko; Kiuchi, Takahiro; Kawana, Keisuke; Oshika, Tetsuro

    2007-03-01

    To report a new technique to visualize bleb leakage using indocyanine green (ICG) staining during trabeculectomy. The ICG solution was widely applied over the filtering bleb including the conjunctival wound before completion of trabeculectomy. This procedure was performed in 48 eyes of 44 consecutive patients undergoing trabeculectomy between December 2004 and October 2005. Without staining, bleb leakage was not identified by the direct observation under the operating microscope. ICG staining clearly visualized aqueous leakage from the bleb in 5 eyes (10.4%). The bleb leakage in these eyes was easily repaired with 10-0 nylon sutures, and no eyes, including these 5 cases, showed bleb leakage after surgery. There were no intraoperative and postoperative complications related to ICG application. The application of ICG during trabeculectomy is a simple and useful technique to facilitate detection and repair of the bleb leakage.

  4. Red alder kitchen cabinets—How does application of commercial stains influence customer choice?

    Treesearch

    David Nicholls; Joseph Roos

    2007-01-01

    A better understanding of consumer reaction and preferences for red alder (Alnus rubra Bong.) secondary products will help Alaska producers in entering new markets. In this study, red alder kitchen cabinets were commercially stained to six different levels and displayed at home shows in Portland, Oregon, and Anchorage, Alaska. The stains simulated...

  5. Role of FNA and Special Stains in Rapid Cytopathological Diagnosis of Pulmonary Nocardiosis.

    PubMed

    Sood, Ridhi; Tyagi, Ruchita; Selhi, Pavneet Kaur; Kaur, Gursheen; Kaur, Harpreet; Singh, Akashdeep

    2018-01-01

    Nocardia, a gram-positive aerobic bacillus of the Actinomycetales family, is a significant opportunistic pathogen in immunocompromised individuals. Clinical and radiological features of pulmonary nocardiosis are nonspecific and can be misdiagnosed as tuberculosis, pneumocystis, staphylococcal or fungal infections, or as malignancy. Aspiration cytology with special stains is a quick and effective approach for accurate diagnosis. We present 7 cases of pulmonary nocardiosis, admitted to the pathology department in a tertiary-care hospital in Punjab. Clinical findings, immune status, laboratory tests, chest radiographs, and computed tomography scans were reviewed. Cytologically, special stains like 1% Ziehl-Neelsen (ZN), 20% ZN, periodic acid-Schiff (PAS), Grocott methenamine silver (GMS), and reticulin stains were studied along with May-Grünwald Giemsa, Papanicolaou, and hematoxylin and eosin. All the patients were immunocompromised. The radiological changes were nonspecific. Cytomorphology showed acute and chronic inflammatory infiltrates with necrosis. None of the cases showed well-defined granulomas. GMS, modified 1% ZN and, Gordon and Sweet reticulin stains highlighted the delicate filamentous bacteria in all cases. PAS and 20% ZN stain for tuberculous bacilli were uniformly negative. FNAC can provide a quick and accurate diagnosis of nocardiosis and thereby facilitate timely medical management. © 2018 S. Karger AG, Basel.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harder, Samantha J.; Isabelle, Martin; DeVorkin, L

    Purpose: This study presents the novel application of Raman spectroscopy (RS) to identify biochemical signatures of radiation response in human non-small cell lung cancer (NSCLC) xenografts, irradiated in vivo. Methods: Human NSCLC cells (H460) were subcutaneously injected into the flanks of 12 mice. Tumours were treated with single fraction radiation doses (0, 5 or 15 Gy) and harvested at 3 days post irradiation. A Renishaw inVia Raman microscope coupled to a 785 nm laser was used to collect Raman spectral maps for each tumour. Immunohistochemistry (IHC) staining for CAIX was used to visualize hypoxia, and co-registration between IHC fluorescence andmore » Raman images was carried out. Results: Principal component analysis revealed radiation induced spectral signatures linked to changes in protein, nucleic acid, lipid and carbohydrates. In particular, a marked increase in glycogen for irradiated tumours was observed. Spatial mapping revealed intra-tumoural heterogeneity in the distribution of glycogen within the tumour, suggesting tumour response to radiation is not globally uniform. Furthermore, co-registration of Raman glycogen maps with CAIX IHC staining showed a correlation between glycogen rich and hypoxic regions of the tissue. Conclusions: We identify glycogen as a unique radiation induced response in NSCLC tumour xenografts, which may reflect inherent metabolic changes associated with radiation response in tissue. This study provides unique insight into the biochemical response of tumours, irradiated in vivo, and demonstrates the potential of RS for detecting radiobiological responses in tumours.« less

  7. Gram staining apparatus for space station applications

    NASA Technical Reports Server (NTRS)

    Molina, T. C.; Brown, H. D.; Irbe, R. M.; Pierson, D. L.

    1990-01-01

    A self-contained, portable Gram staining apparatus (GSA) has been developed for use in the microgravity environment on board the Space Station Freedom. Accuracy and reproducibility of this apparatus compared with the conventional Gram staining method were evaluated by using gram-negative and gram-positive controls and different species of bacteria grown in pure cultures. A subsequent study was designed to assess the performance of the GSA with actual specimens. A set of 60 human and environmental specimens was evaluated with the GSA and the conventional Gram staining procedure. Data obtained from these studies indicated that the GSA will provide the Gram staining capability needed for the microgravity environment of space.

  8. Embedding, serial sectioning and staining of zebrafish embryos using JB-4 resin.

    PubMed

    Sullivan-Brown, Jessica; Bisher, Margaret E; Burdine, Rebecca D

    2011-01-01

    Histological techniques are critical for observing tissue and cellular morphology. In this paper, we outline our protocol for embedding, serial sectioning, staining and visualizing zebrafish embryos embedded in JB-4 plastic resin-a glycol methacrylate-based medium that results in excellent preservation of tissue morphology. In addition, we describe our procedures for staining plastic sections with toluidine blue or hematoxylin and eosin, and show how to couple these stains with whole-mount RNA in situ hybridization. We also describe how to maintain and visualize immunofluorescence and EGFP signals in JB-4 resin. The protocol we outline-from embryo preparation, embedding, sectioning and staining to visualization-can be accomplished in 3 d. Overall, we reinforce that plastic embedding can provide higher resolution of cellular details and is a valuable tool for cellular and morphological studies in zebrafish.

  9. Batch Immunostaining for Large-Scale Protein Detection in the Whole Monkey Brain

    PubMed Central

    Zangenehpour, Shahin; Burke, Mark W.; Chaudhuri, Avi; Ptito, Maurice

    2009-01-01

    Immunohistochemistry (IHC) is one of the most widely used laboratory techniques for the detection of target proteins in situ. Questions concerning the expression pattern of a target protein across the entire brain are relatively easy to answer when using IHC in small brains, such as those of rodents. However, answering the same questions in large and convoluted brains, such as those of primates presents a number of challenges. Here we present a systematic approach for immunodetection of target proteins in an adult monkey brain. This approach relies on the tissue embedding and sectioning methodology of NeuroScience Associates (NSA) as well as tools developed specifically for batch-staining of free-floating sections. It results in uniform staining of a set of sections which, at a particular interval, represents the entire brain. The resulting stained sections can be subjected to a wide variety of analytical procedures in order to measure protein levels, the population of neurons expressing a certain protein. PMID:19636291

  10. A memory-efficient staining algorithm in 3D seismic modelling and imaging

    NASA Astrophysics Data System (ADS)

    Jia, Xiaofeng; Yang, Lu

    2017-08-01

    The staining algorithm has been proven to generate high signal-to-noise ratio (S/N) images in poorly illuminated areas in two-dimensional cases. In the staining algorithm, the stained wavefield relevant to the target area and the regular source wavefield forward propagate synchronously. Cross-correlating these two wavefields with the backward propagated receiver wavefield separately, we obtain two images: the local image of the target area and the conventional reverse time migration (RTM) image. This imaging process costs massive computer memory for wavefield storage, especially in large scale three-dimensional cases. To make the staining algorithm applicable to three-dimensional RTM, we develop a method to implement the staining algorithm in three-dimensional acoustic modelling in a standard staggered grid finite difference (FD) scheme. The implementation is adaptive to the order of spatial accuracy of the FD operator. The method can be applied to elastic, electromagnetic, and other wave equations. Taking the memory requirement into account, we adopt a random boundary condition (RBC) to backward extrapolate the receiver wavefield and reconstruct it by reverse propagation using the final wavefield snapshot only. Meanwhile, we forward simulate the stained wavefield and source wavefield simultaneously using the nearly perfectly matched layer (NPML) boundary condition. Experiments on a complex geologic model indicate that the RBC-NPML collaborative strategy not only minimizes the memory consumption but also guarantees high quality imaging results. We apply the staining algorithm to three-dimensional RTM via the proposed strategy. Numerical results show that our staining algorithm can produce high S/N images in the target areas with other structures effectively muted.

  11. CMV Disease in IBD: Comparison of Diagnostic Tests and Correlation with Disease Outcome.

    PubMed

    Johnson, Jessica; Affolter, Kajsa; Boynton, Kathleen; Chen, Xinjian; Valentine, John; Peterson, Kathryn

    2018-04-30

    Significance of cytomegalovirus (CMV) in inflammatory bowel disease (IBD) is unclear due to pathobiology, numerous CMV tests, and disparate treatment outcomes. Retrospective chart review was done on patients with positive qualitative CMV tissue polymerase chain reaction (PCR) from 2005-2013 at a tertiary referral hospital. Frequency of PCR+, hematoxylin and eosin staining(HE)+, histopathology and immunohistochemistry (IHC)+ was assessed. IHC was assessed on a sample of PCR- tissues. Surgery rates were correlated with CMV testing and treatment. PCR was done on 310 samples from 180 patients. Thirty-seven samples were PCR+ (51.4% PCR+ only, 35.1% IHC/PCR+, 13.5% HE/IHC/PCR+). The H&E frequently failed to detect CMV identified on extensive IHC. Of 13 PCR- samples tested with IHC, 100% were negative. Twenty-five patients were CMV+ (40% PCR+, 40% IHC/PCR+, 20% HE/IHC/PCR+). Surgery rates increased with number of positive tests: 60% in IHC/PCR+ and 80% in HE/IHC/PCR+, compared to 26.8% in PCR- or PCR+ (P = 0.03, P = 0.02, respectively). There were 20/25 PCR+ patients who received CMV treatment. Surgery occurred in 80% of HE+ patients despite treatment and 100% of IHC+ patients without treatment. Rates of CMV+ testing and surgical risk varied by test modality. PCR+ results were most frequent but alone did not detect clinically significant CMV. HE+ testing was least frequent and associated with highest surgical rate, despite treatment. CMV treatment may benefit IHC+ patients most, supporting immunostaining as optimal diagnostic test for clinically significant CMV in IBD. In PCR+ samples, HE frequently did not detect CMV identified on extensive IHC. In PCR- samples, data suggest IHC is likely negative. Consider using qualitative PCR to guide extensive immunostaining.

  12. HALE STAIN FOR SIALIC ACID-CONTAINING MUCINS. ADAPTATION TO ELECTRON MICROSCOPY.

    PubMed

    GASIC, G; BERWICK, L

    1963-10-01

    The feasibility of using the Hale stain to identify cellular sialic acid-containing mucins by electron microscopy was investigated. Three kinds of mouse ascites tumor cells were fixed in neutral buffered formalin, exposed to fresh colloidal ferric oxide, treated with potassium ferrocyanide, imbedded in Selectron, and sectioned for electron microscopy. Additional staining with uranyl acetate and potassium permanganate was done after sectioning in order to increase contrast. Those cells known to be coated with sialomucin showed deposits of electron-opaque ferric ferrocyanide crystals in the areas where sialomucin concentrations were expected. When these cells were treated with neuraminidase beforehand, these deposits did not appear. It was concluded that, with the precautions and modifications described, the Hale stain can be successfully combined with electron microscopy to identify sialomucin.

  13. Comparison of staining of mitotic figures by haematoxylin and eosin-and crystal violet stains, in oral epithelial dysplasia and squamous cell carcinoma.

    PubMed

    Ankle, Madhuri R; Kale, Alka D; Charantimath, Seema

    2007-01-01

    Mitosis of cells gives rise to tissue integrity. Defects during mitosis bring about abnormalities. Excessive proliferation of cells due to increased mitosis is one such outcome, which is the hallmark in precancer and cancer. The localization of proliferating cells or their precursors may not be obvious and easy. Establishing an easy way to distinguish these mitotic cells will help in grading and understanding their biological potential. Although immunohistochemistry is an advanced method in use, the cost and time factor makes it less feasible for many laboratories. Selective histochemical stains like toluidine blue, giemsa and crystal violet have been used in tissues including the developing brain, neural tissue and skin. 1) To compare the staining of mitotic cells in haematoxylin and eosin with that in crystal violet. 2) To compare the number of mitotic figures present in normal oral mucosa, epithelial dysplasia and oral squamous cell carcinoma in crystal violet-stained sections with that in H and E-stained sections. Ten tissues of normal oral mucosa and 15 tissues each of oral epithelial dysplasia seen in tobacco-associated leukoplakia and squamous cell carcinoma were studied to evaluate the selectivity of 1% crystal violet for mitotic figures. The staining was compared with standard H and E staining. Statistical analysis was done using Mann-Whitney U test. A statistically significant increase in the mean mitotic count was observed in crystal violet-stained sections of epithelial dysplasia as compared to the H and E-stained sections (p=0.0327). A similar increase in the mitotic counts was noted in crystal violet-stained sections of oral squamous cell carcinoma as compared to the H and E-stained sections.(p=0.0443). No significant difference was found in the mitotic counts determined in dysplasia or carcinoma by either the crystal violet (p=0.4429) or the H and E-staining techniques (p=0.2717). One per cent crystal violet provides a definite advantage over the H

  14. Control of brown stain: in Eastern white pine

    Treesearch

    Robert E. Stutz; Peter Koch; Millard L. Oldham

    1961-01-01

    Degrade caused by brown stain and blue stain in eastern white pine was virtually eliminated by the use of sap stain chemicals and sodium azide. Combinations of buffered sodium azide with both sodium pentachlorophenate plus borax and buffered ethyl mercury phosphate were effective.

  15. Interlaboratory comparison of immunohistochemical testing for HER2: results of the 2004 and 2005 College of American Pathologists HER2 Immunohistochemistry Tissue Microarray Survey.

    PubMed

    Fitzgibbons, Patrick L; Murphy, Douglas A; Dorfman, David M; Roche, Patrick C; Tubbs, Raymond R

    2006-10-01

    Correct assessment of human epidermal growth factor receptor 2 (HER2) status is essential in managing patients with invasive breast carcinoma, but few data are available on the accuracy of laboratories performing HER2 testing by immunohistochemistry (IHC). To review the results of the 2004 and 2005 College of American Pathologists HER2 Immunohistochemistry Tissue Microarray Survey. The HER2 survey is designed for laboratories performing immunohistochemical staining and interpretation for HER2. The survey uses tissue microarrays, each consisting of ten 3-mm tissue cores obtained from different invasive breast carcinomas. All cases are also analyzed by fluorescence in situ hybridization. Participants receive 8 tissue microarrays (80 cases) with instructions to perform immunostaining for HER2 using the laboratory's standard procedures. The laboratory interprets the stained slides and returns results to the College of American Pathologists for analysis. In 2004 and 2005, a core was considered "graded" when at least 90% of laboratories agreed on the result--negative (0, 1+) versus positive (2+, 3+). This interlaboratory comparison survey included 102 laboratories in 2004 and 141 laboratories in 2005. Of the 160 cases in both surveys, 111 (69%) achieved 90% consensus (graded). All 43 graded cores scored as IHC-positive were fluorescence in situ hybridization-positive, whereas all but 3 of the 68 IHC-negative graded cores were fluorescence in situ hybridization-negative. Ninety-seven (95%) of 102 laboratories in 2004 and 129 (91%) of 141 laboratories in 2005 correctly scored at least 90% of the graded cores. Performance among laboratories performing HER2 IHC in this tissue microarray-based survey was excellent. Cores found to be IHC-positive or IHC-negative by participant consensus can be used as validated benchmarks for interlaboratory comparison, allowing laboratories to assess their performance and determine if improvements are needed.

  16. Gram staining apparatus for space station applications.

    PubMed Central

    Molina, T C; Brown, H D; Irbe, R M; Pierson, D L

    1990-01-01

    A self-contained, portable Gram staining apparatus (GSA) has been developed for use in the microgravity environment on board the Space Station Freedom. Accuracy and reproducibility of this apparatus compared with the conventional Gram staining method were evaluated by using gram-negative and gram-positive controls and different species of bacteria grown in pure cultures. A subsequent study was designed to assess the performance of the GSA with actual specimens. A set of 60 human and environmental specimens was evaluated with the GSA and the conventional Gram staining procedure. Data obtained from these studies indicated that the GSA will provide the Gram staining capability needed for the microgravity environment of space. Images PMID:1690529

  17. Grade of eosinophilia versus symptoms in patients with dysphagia and esophageal eosinophilia.

    PubMed

    Larsson, H; Norder Grusell, E; Tegtmeyer, B; Ruth, M; Bergquist, H; Bove, M

    2016-11-01

    The aim of this study was to assess whether the symptom severity and health-related quality of life (HRQL) of patients with dysphagia and esophageal eosinophilia correlate with disease activity as expressed by the number of eosinophils in the esophageal mucosa. This study included newly diagnosed (n = 58) or relapsed patients (n = 7), where 40% were diagnosed in connection with esophageal bolus impaction. The mean age was 45 years (19-88), and 74% were men. Symptoms and HRQL were recorded using the Watson Dysphagia Scale (WDS), the European Organization for Research and Treatment of Cancer Quality of Life Questionnaire - Oesophageal Module 18 and the Short Form-36 Questionnaire. Histological samples gathered from the proximal and distal esophageal mucosa were stained using both hematoxylin and eosin (HE) and an immunohistochemical (IHC) technique against 'Eosinophil Major Basic Protein,' and the peak number of eosinophils per high-power field was assessed. More eosinophils were detected after IHC staining than HE staining (P < 0.001). No correlation was found between symptoms or the HRQL and the number of eosinophils. However, higher numbers of eosinophils at the proximal esophagus were found in patients with concomitant bolus impaction (IHC P < 0.05 and HE P < 0.05) and could serve as a risk marker. © 2015 International Society for Diseases of the Esophagus.

  18. Ulex Europaeus Agglutinin-1 Is a Reliable Taste Bud Marker for In Situ Hybridization Analyses.

    PubMed

    Yoshimoto, Joto; Okada, Shinji; Kishi, Mikiya; Misaka, Takumi

    2016-03-01

    Taste signals are received by taste buds. To better understand the taste reception system, expression patterns of taste-related molecules are determined by in situ hybridization (ISH) analyses at the histological level. Nevertheless, even though ISH is essential for determining mRNA expression, few taste bud markers can be applied together with ISH. Ulex europaeus agglutinin-1 (UEA-1) appears to be a reliable murine taste bud marker based on immunohistochemistry (IHC) analyses. However, there is no evidence as to whether UEA-1 can be used for ISH. Thus, the present study evaluated UEA-1 using various histochemical methods, especially ISH. When lectin staining was performed after ISH procedures, UEA-1 clearly labeled taste cellular membranes and distinctly indicated boundaries between taste buds and the surrounding epithelial cells. Additionally, UEA-1 was determined as a taste bud marker not only when used in single-colored ISH but also when employed with double-labeled ISH or during simultaneous detection using IHC and ISH methods. These results suggest that UEA-1 is a useful marker when conducting analyses based on ISH methods. To clarify UEA-1 staining details, multi-fluorescent IHC (together with UEA-1 staining) was examined, resulting in more than 99% of cells being labeled by UEA-1 and overlapping with KCNQ1-expressing cells. © 2016 The Histochemical Society.

  19. Ulex Europaeus Agglutinin-1 Is a Reliable Taste Bud Marker for In Situ Hybridization Analyses

    PubMed Central

    Yoshimoto, Joto; Okada, Shinji; Kishi, Mikiya; Misaka, Takumi

    2015-01-01

    Taste signals are received by taste buds. To better understand the taste reception system, expression patterns of taste-related molecules are determined by in situ hybridization (ISH) analyses at the histological level. Nevertheless, even though ISH is essential for determining mRNA expression, few taste bud markers can be applied together with ISH. Ulex europaeus agglutinin-1 (UEA-1) appears to be a reliable murine taste bud marker based on immunohistochemistry (IHC) analyses. However, there is no evidence as to whether UEA-1 can be used for ISH. Thus, the present study evaluated UEA-1 using various histochemical methods, especially ISH. When lectin staining was performed after ISH procedures, UEA-1 clearly labeled taste cellular membranes and distinctly indicated boundaries between taste buds and the surrounding epithelial cells. Additionally, UEA-1 was determined as a taste bud marker not only when used in single-colored ISH but also when employed with double-labeled ISH or during simultaneous detection using IHC and ISH methods. These results suggest that UEA-1 is a useful marker when conducting analyses based on ISH methods. To clarify UEA-1 staining details, multi-fluorescent IHC (together with UEA-1 staining) was examined, resulting in more than 99% of cells being labeled by UEA-1 and overlapping with KCNQ1-expressing cells. PMID:26718243

  20. A novel washing algorithm for underarm stain removal

    NASA Astrophysics Data System (ADS)

    Acikgoz Tufan, H.; Gocek, I.; Sahin, U. K.; Erdem, I.

    2017-10-01

    After contacting with human sweat which comprise around 27% sebum, anti-perspirants comprising aluminium chloride or its compounds form a jel-like structure whose solubility in water is very poor. In daily use, this jel-like structure closes sweat pores and hinders wetting of skin by sweat. However, when in contact with garments, they form yellowish stains at the underarm of the garments. These stains are very hard to remove with regular machine washing. In this study, first of all, we focused on understanding and simulating such stain formation on the garments. Two alternative procedures are offered to form jel-like structures. On both procedures, commercially available spray or deo-stick type anti-perspirants, standard acidic and basic sweat solutions and artificial sebum are used to form jel-like structures, and they are applied on fabric in order to get hard stains. Secondly, after simulation of the stain on the fabric, we put our efforts on developing a washing algorithm specifically designed for removal of underarm stains. Eight alternative washing algorithms are offered with varying washing temperature, amounts of detergent, and pre-stain removal procedures. Better algorithm is selected by comparison of Tristimulus Y values after washing.

  1. 21 CFR 864.1850 - Dye and chemical solution stains.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dye and chemical solution stains. 864.1850 Section... (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Biological Stains § 864.1850 Dye and chemical solution stains. (a) Identification. Dye and chemical solution stains for medical purposes are mixtures of...

  2. 21 CFR 864.1850 - Dye and chemical solution stains.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Dye and chemical solution stains. 864.1850 Section... (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Biological Stains § 864.1850 Dye and chemical solution stains. (a) Identification. Dye and chemical solution stains for medical purposes are mixtures of...

  3. 21 CFR 864.1850 - Dye and chemical solution stains.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Dye and chemical solution stains. 864.1850 Section... (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Biological Stains § 864.1850 Dye and chemical solution stains. (a) Identification. Dye and chemical solution stains for medical purposes are mixtures of...

  4. 21 CFR 864.1850 - Dye and chemical solution stains.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Dye and chemical solution stains. 864.1850 Section... (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Biological Stains § 864.1850 Dye and chemical solution stains. (a) Identification. Dye and chemical solution stains for medical purposes are mixtures of...

  5. 21 CFR 864.1850 - Dye and chemical solution stains.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Dye and chemical solution stains. 864.1850 Section... (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Biological Stains § 864.1850 Dye and chemical solution stains. (a) Identification. Dye and chemical solution stains for medical purposes are mixtures of...

  6. Immunohistochemical and radiological characterization of wound healing in porcine liver after radiofrequency ablation.

    PubMed

    Stadlbauer, Vanessa; Lang-Olip, Ingrid; Leber, Bettina; Mayrhauser, Ursula; Koestenbauer, Sonja; Tawdrous, Monika; Moche, Michael; Sereinigg, Michael; Seider, Daniel; Iberer, Florian; Wiederstein-Grasser, Iris; Portugaller, Rupert Horst; Stiegler, Philipp

    2016-01-01

    Radiofrequency ablation (RFA) is a minimal invasive therapeutic option for patients with hepatocellular carcinoma or liver metastases. We investigated RFA-induced cellular changes in the liver of pigs. Healthy pigs (n=18) were sacrificed between day 0 and 3 months after RFA. The wound healing process was evaluated by computed tomography (CT), chromotrope anilinblue (CAB) staining of large-scale and standard tissue sections. Immunohistochemistry (IHC) for heat shock protein 70, Caspase-3, Ki67, Reelin, Vinculin, Vimentin and α-SMA was perfomed. One day after RFA, CAB staining showed cell damage and massive hyperaemia. All IHC markers were predominantly expressed at the outer borders of the lesion, except Reelin, which was mainly detected in untreated liver regions. By staining for Hsp70, the heat stress during RFA was monitored, which was most distinct 1-2 days after RFA. CT revealed decreased lesion size after one week. Development of a Vimentin and α-SMA positive fibrotic capsule was observed. In the early phase signs of cell damage, apoptosis and proliferation are dominant. Reduced expression of Reelin suggests a minor role of hepatic stellate cells in the RFA zone. After one week myofibroblasts become prominent and contribute to the development of the fibrotic capsule. This elucidates the pathophysiology of RFA and could contribute to the future optimization of RFA procedures.

  7. 7 CFR 28.442 - Middling Yellow Stained Color.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Middling Yellow Stained Color. 28.442 Section 28.442... Stained Color. Middling Yellow Stained Color is American Upland cotton which in color is deeper than Middling Tinged Color. [57 FR 34498, Aug. 5, 1992] below color grade cotton ...

  8. 7 CFR 28.442 - Middling Yellow Stained Color.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Middling Yellow Stained Color. 28.442 Section 28.442... Stained Color. Middling Yellow Stained Color is American Upland cotton which in color is deeper than Middling Tinged Color. [57 FR 34498, Aug. 5, 1992] below color grade cotton ...

  9. 7 CFR 28.442 - Middling Yellow Stained Color.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Middling Yellow Stained Color. 28.442 Section 28.442... Stained Color. Middling Yellow Stained Color is American Upland cotton which in color is deeper than Middling Tinged Color. [57 FR 34498, Aug. 5, 1992] below color grade cotton ...

  10. 7 CFR 28.442 - Middling Yellow Stained Color.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Middling Yellow Stained Color. 28.442 Section 28.442... Stained Color. Middling Yellow Stained Color is American Upland cotton which in color is deeper than Middling Tinged Color. [57 FR 34498, Aug. 5, 1992] below color grade cotton ...

  11. 7 CFR 28.442 - Middling Yellow Stained Color.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Middling Yellow Stained Color. 28.442 Section 28.442... Stained Color. Middling Yellow Stained Color is American Upland cotton which in color is deeper than Middling Tinged Color. [57 FR 34498, Aug. 5, 1992] below color grade cotton ...

  12. Use of DNA stains in immunophenotyping by slide-based cytometry

    NASA Astrophysics Data System (ADS)

    Gerstner, Andreas O. H.; Laffers, Wiebke; Bootz, Friedrich; Tarnok, Attila

    2003-06-01

    Immunophenotyping of peripheral blood leukocytes (PBL) is a very well documented application of Slide Based Cytometry (SBC). As for any other assay it is of highest importance to ensure that all cells which are relevant for an analysis are recognized. Unlike assays for cultured cells which have homogenous morphology immunophenotyping of PBLs is performed on cells with heterogeneous size and shape. Therefore, triggering on parameters related to cell morphology might lead to an incomplete analysis of just a subset of cells especially in pathological conditions. Several dyes stain DNA specifically in a wide variety of emission spectra. Many of them show some influence of the chromatin condensation and organization on the staining intensity. DNA dyes therefore can be used to differentiate between cell types having the same ploidy. This can be exploited for immunophenotyping since some dyes therefore can partially replace antibody staining. The concept of using DNA dyes in the setting of immunostaining has the following advantages: (1) nuclear staining provides a stable and easy triggering signal that guarantees both, that neither cells are excluded nor that debris or polluting particles are included into the analysis; (2) some DNA dyes differentiate between mononuclear and polymorphonuclear cells. A disadvantage of DNA dyes is that mostly cells have to be permeabilized. Because of this only one set of immunophenotypic markers can be stained, cells are fixed and permeabilized, and then nuclei are stained with the appropriate DNA dye. In the study we demonstrate the use of the most commonly available DNA dyes (7-AAD, To-Pro, To-To, PI etc.) in their applicability in immunophenotyping. An overview of spectral properties, fluorescence spill-over and optimal combinations with surface antigen staining will be shown. As in general for SBC only very small sample volumes are needed. This allows to serially analyze PBL in clinical settings that up to now could not be studied in

  13. Short Nissl staining for incubated cryostat sections of the brain.

    PubMed

    Lindroos, O F

    1991-01-01

    Nissl stain often binds poorly to cryostat sections which have been incubated in solutions of radiolabeled ligands. Such incubation is used in receptor autoradiography of the brain when using the in vitro method. We have developed a rapid (16 min) modification of Nissl staining for sections that bind stain poorly, e.g., incubated sections. The method stains well sections which cannot be stained with other rapid Nissl staining methods.

  14. Comparative study of IDH1 mutations in gliomas by immunohistochemistry and DNA sequencing.

    PubMed

    Agarwal, Shipra; Sharma, Mehar Chand; Jha, Prerana; Pathak, Pankaj; Suri, Vaishali; Sarkar, Chitra; Chosdol, Kunzang; Suri, Ashish; Kale, Shashank Sharad; Mahapatra, Ashok Kumar; Jha, Pankaj

    2013-06-01

    Mutations involving isocitrate dehydrogenase 1 (IDH 1) occur in a high proportion of diffuse gliomas, with implications on diagnosis and prognosis. About 90% involve exon 4 at codon 132, replacing amino acid arginine with histidine (R132H). Rarer ones include R132C, R132S, R132G, R132L, R132V, and R132P. Most authors have used DNA-based methods to assess IDH1 status. Preliminary studies comparing imunohistochemistry (IHC) with IDH1-R132H mutation-specific antibodies have shown concordance with DNA sequencing and no cross-reactivity with wild-type IDH1 or other mutant proteins. The present study compares results of IHC with DNA sequencing in diffuse gliomas. Fifty diffuse gliomas with frozen tissue samples for DNA sequencing and adequate tissue in paraffin blocks for IHC using IDH1-R132H specific antibody were assessed for IDH1 mutations. Concordance of findings between IHC and DNA sequencing was noted in 88% (44/50) cases. All 6 cases with discrepancy were immunopositive with DIA-H09 antibody. While in 3 of these 6 cases, DNA sequencing failed to reveal any mutations, R132L (arginine replaced by leucine) mutation was found in the rest 3 cases. Interestingly, of the immunopositive cases, 46.6% (14/30) showed immunostaining in only a fraction of tumor cells. IHC is an easy and quick method of detecting IDH1-R132H mutations, but there may be some discrepancies between IHC and DNA sequencing. Although there were no false-negative cases, cross-reactivity with IDH1-R132L was seen in 3, a finding not reported thus far. Because of more universal availability of IHC over genetic testing, cross-reactivity and staining heterogeneity may have bearing over its use in detecting IDH1-R132H mutation in gliomas.

  15. Near-UV laser treatment of extrinsic dental enamel stains.

    PubMed

    Schoenly, J E; Seka, W; Featherstone, J D B; Rechmann, P

    2012-04-01

    The selective ablation of extrinsic dental enamel stains using a 400-nm laser is evaluated at several fluences for completely removing stains with minimal damage to the underlying enamel. A frequency-doubled Ti:sapphire laser (400-nm wavelength, 60-nanosecond pulse duration, 10-Hz repetition rate) was used to treat 10 extracted human teeth with extrinsic enamel staining. Each tooth was irradiated perpendicular to the surface in a back-and-forth motion over a 1-mm length using an ∼300-µm-diam 10th-order super-Gaussian beam with fluences ranging from 0.8 to 6.4 J/cm(2) . Laser triangulation determined stain depth and volume removed by measuring 3D surface images before and after irradiation. Scanning electron microscopy evaluated the surface roughness of enamel following stain removal. Fluorescence spectroscopy measured spectra of unbleached and photobleached stains in the spectral range of 600-800 nm. Extrinsic enamel stains are removed with laser fluences between 0.8 and 6.4 J/cm(2) . Stains removed on sound enamel leave behind a smooth enamel surface. Stain removal in areas with signs of earlier cariogenic acid attacks resulted in isolated and randomly located laser-induced, 50-µm-diam enamel pits. These pits contain 0.5-µm diam, smooth craters indicative of heat transfer from the stain to the enamel and subsequent melting and water droplet ejection. Ablation stalling of enamel stains is typically observed at low fluences (<3 J/cm(2) ) and is accompanied by a drastic reduction in porphyrin fluorescence from the Soret band. Laser ablation of extrinsic enamel stains at 400 nm is observed to be most efficient above 3 J/cm(2) with minimal damage to the underlying enamel. Unsound underlying enamel is also observed to be selectively removed after irradiation. Copyright © 2012 Wiley Periodicals, Inc.

  16. Effects of the change in cutoff values for human epidermal growth factor receptor 2 status by immunohistochemistry and fluorescence in situ hybridization: a study comparing conventional brightfield microscopy, image analysis-assisted microscopy, and interobserver variation.

    PubMed

    Atkinson, Roscoe; Mollerup, Jens; Laenkholm, Anne-Vibeke; Verardo, Mark; Hawes, Debra; Commins, Deborah; Engvad, Birte; Correa, Adrian; Ehlers, Charlotte Cort; Nielsen, Kirsten Vang

    2011-08-01

    New guidelines for HER2 testing have been introduced. To evaluate the difference in HER2 assessment after introduction of new cutoff levels for both immunohistochemistry (IHC) and fluorescence in situ hybridization (FISH) and to compare interobserver agreement and time to score between image analysis and conventional microscopy. Samples from 150 patients with breast cancer were scored by 7 pathologists using conventional microscopy, with a cutoff of both 10% and 30% IHC-stained cells, and using automated microscopy with image analysis. The IHC results were compared individually and to HER2 status as determined by FISH, using both the approved cutoff of 2.0 and the recently introduced cutoff of 2.2. High concordance was found in IHC scoring among the 7 pathologists. The 30% cutoff led to slightly fewer positive IHC observations. Introduction of a FISH equivocal zone affected 4% of the FISH scores. If cutoff for FISH is kept at 2.0, no difference in patient selection is found between the 10% and the 30% IHC cutoff. Among the 150 breast cancer samples, the new 30% IHC and 2.2 FISH cutoff levels resulted in one case without a firm diagnosis because both IHC and FISH were equivocal. Automated microscopy and image analysis-assisted IHC led to significantly better interobserver agreement among the 7 pathologists, with an increase in mean scoring time of only about 30 seconds per slide. The change in cutoff levels led to a higher concordance between IHC and FISH, but fewer samples were classified as HER2 positive.

  17. Expression of human telomerase reverse transcriptase protein in oral epithelial dysplasia and oral squamous cell carcinoma: An immunohistochemical study

    PubMed Central

    Raghunandan, Bangalore Nagarajachar; Sanjai, Karpagaselvi; Kumaraswamy, Jayalakshmi; Papaiah, Lokesh; Pandey, Bhavna; Jyothi, Bellur MadhavaRao

    2016-01-01

    compared using analysis of variance (ANOVA). A P < 0.05 was considered to be statistically significant. Results: The mean hTERT positive cells in the study groups were as follows, 62.91% in normal oral mucosa samples, 77.06% in oral epithelial dysplasia cases, and 81.48% in OSCC. In 61.9% of oral epithelial dysplasia and 65% of OSCC in our study, staining was visualized within the nucleus predominantly in the dot like pattern. There was a statistically significant difference in the nature of nuclear stain between oral epithelial dysplasia and OSCC (P = 0.023). Conclusions: Our results suggests that the mean percentage of cells showing hTERT expression steadily increased from normal oral mucosa to oral epithelial dysplasia to OSCC. The steady trend of increase in the percentage of cells was evident in different grades of oral epithelial dysplasia group and OSCC. The nature of hTERT staining did show variations among the three groups and promise to be a potential surrogate marker for malignant transformation. Further studies using IHC on larger sample size and clinical follow-up of these patients will be ascertaining the full potential of hTERT as a surrogate marker of epithelial transformation. PMID:27194869

  18. Newer applications of the histological stain prepared from Pterocarpus santalinus.

    PubMed

    Sen Gupta, P C; Mukherjee, A K

    1981-03-01

    A histological stain prepared from the heartwood of Pterocarpus santalinus Linn. has been found to be an excellent nuclear stain for various cells of animal and plant origin. As an elastic tissue stain, the results are comparable to standard elastic tissue stains. The striations of voluntary muscle fibers are well shown. The Nissl granules and fibers of cranial nerves in the pons are visualized. When counterstained with light green, it differentially stains muscle and fibrous tissue. The stain can be used as counterstain with certain histochemical procedures with satisfactory results. The preparation and use of this versatile stain are described.

  19. A case of perforated sigmoid diverticulitis in which gram staining of ascitic fluid was useful for diagnosis.

    PubMed

    Tsuchida, Junko; Fujita, Shouhei; Kawano, Fumihiro; Tsukamoto, Ryoichi; Honjo, Kunpei; Naito, Shigetoshi; Ishiyama, Shun; Miyano, Shozo; Machida, Michio; Kitabatake, Toshiaki; Fujisawa, Minoru; Kojima, Kuniaki; Ogura, Kanako; Matsumoto, Toshiharu

    2014-01-01

    An 85-year-old woman was admitted to our hospital for steroid therapy for relapsing nephrotic syndrome. During hospitalization, she complained of sudden epigastric pain at night. Although there were signs of peritoneal irritation, CT showed a large amount of ascitic fluid, but no free intraperitoneal gas. Gram staining of ascitic fluid obtained by abdominal paracentesis showed Gram-negative rods, which raised a strong suspicion of gastrointestinal perforation and peritonitis. Therefore, emergency surgery was performed. Exploration of the colon showed multiple sigmoid diverticula, one of which was perforated. The patient underwent an emergency Hartmann's procedure. Imaging studies failed to reveal any evidence of gastrointestinal perforation, presenting a diagnostic challenge. However, a physician performed rapid Gram staining of ascitic fluid at night when laboratory technicians were absent, had a strong suspicion of gastrointestinal perforation, and performed emergency surgery. Gram staining is superior in rapidity, and ascitic fluid Gram staining can aid in diagnosis, suggesting that it should be actively performed. We report this case, with a review of the literature on the significance of rapid diagnosis by Gram staining.

  20. Stain susceptibility of composite and ceramic CAD/CAM blocks versus direct resin composites with different resinous matrices.

    PubMed

    Alharbi, Amal; Ardu, Stefano; Bortolotto, Tissiana; Krejci, Ivo

    2017-04-01

    To evaluate the stain susceptibility of CAD/CAM blocks and direct composite after long term exposure to various staining agents. 40 disk-shaped samples were fabricated from each of nine materials; six CAD/CAM (Vitablocs Mark II, Paradigm MZ100, Experimental Vita Hybrid Ceramic, Vita Enamic, Experimental Kerr and Lava Ultimate) and three direct composites (Filtek Supreme, Venus Diamond and Filtek Silorane). Samples were randomly divided into five groups (n = 8) according to different staining solutions (distilled water, tea, red wine, coffee and artificial saliva). Initial L*a*b* values were assessed using a calibrated digital spectrophotometer. Specimens were immersed in staining solutions and stored in an incubator at 37 °C for 120 days. L*a*b* values were assessed again and color change (∆E) was calculated as difference between recorded L*a*b* values. ANOVA, and Duncan test were used to identify differences between groups (α = 0.05). Significant differences in ∆E values were detected between materials (p = 0.000). Among all staining solutions, the highest ∆E value was observed with red wine. The new CAD/CAM blocks (Vita Enamic, Vita Hybrid Ceramic and Lava Ultimate) showed the highest resistance to staining compared to the MZ100 composite resin blocks. Filtek Silorane, a direct composite, showed high stain resistance values compared to CAD/CAM materials and other direct composites. Ceramic and composite CAD/CAM blocks had lower staining susceptibility than methacrylate based direct composite. Staining susceptibility of the new resin based CAD/CAM materials Vita Enamic and Lava Ultimate was comparable to feldspathic ceramic blocks (Vitablocs Mark II). Filtek Silorane showed promising results that were comparable to some CAD/CAM blocks.

  1. BAP1 immunohistochemistry and p16 FISH results in combination provide higher confidence in malignant pleural mesothelioma diagnosis: ROC analysis of the two tests.

    PubMed

    Hida, Tomoyuki; Hamasaki, Makoto; Matsumoto, Shinji; Sato, Ayuko; Tsujimura, Tohru; Kawahara, Kunimitsu; Iwasaki, Akinori; Okamoto, Tatsuro; Oda, Yoshinao; Honda, Hiroshi; Nabeshima, Kazuki

    2016-10-01

    Differentiation of malignant pleural mesothelioma (MPM) from benign mesothelial proliferation remains problematic. Loss of nuclear staining of BRCA1-associated protein 1 (BAP1; detected using immunohistochemistry (IHC)) and homozygous deletion (HD) of p16 (detected using fluorescence in situ hybridization (FISH)) are useful for differentiation of MPM from reactive mesothelial hyperplasia (RMH), but the correlation between BAP1 expression loss and p16 HD has not been fully described. We performed BAP1 IHC and p16-specific FISH for 40 MPM and 20 RMH cases, and measured proportions of cells showing BAP1 expression and p16 HD for each case. The diagnostic accuracy for MPM and the cut-off values of the two methods were assessed using receiver operating characteristic (ROC) analysis. BAP1 expression loss, p16 HD and coexistence of both were present in 27 (67.5 %), 27 (67.5 %) and 17 (42.5 %) MPM cases, respectively. Three MPM cases (7.5 %) and all 20 RMH cases had neither BAP1 loss nor p16 HD. There was no correlation between the results of the two methods. Their combination showed higher sensitivity (92.5 %, 37/40) and estimated probability than BAP1 IHC and p16-specific FISH used alone. BAP1 IHC and p16-specific FISH have independent diagnostic value, and have increased reliability when used in combination, for MPM diagnosis. © 2016 Japanese Society of Pathology and John Wiley & Sons Australia, Ltd.

  2. Corneal and conjunctival epithelial staining in hydrogel contact lens wearers.

    PubMed

    Brautaset, Rune L; Nilsson, Maria; Leach, Norman; Miller, William L; Gire, Anisa; Quintero, Sam; Bergmanson, Jan P G

    2008-11-01

    The purpose of this study was to investigate the prevalence of conjunctival and corneal epithelial staining in soft contact lens wearers and to see if staining could be associated with factors such as type of lens worn, wearing time, care system, age, and sex. The records of 338 adapted hydrogel contact lens wearers were examined retrospectively. Conjunctival staining was found to be present in 32.5% of the subjects and corneal staining was found to be present in 19.5% of subjects. None of the subjects had staining above grade 2 using the Cornea and Contact Lens Research Unit scale. Because of the low prevalence of staining, the low grading of staining found and the large variation in refractive power, lens type worn, wearing modality, and solution used statistical analysis for association between staining and different factors could only be performed for the association between sex and staining and between corneal and conjunctival staining. However, no statistical significant association could be demonstrated. Despite the low prevalence of staining the conjunctiva and cornea should be examined carefully in contact lens wearers and prospective wearers because the conjunctival and corneal epithelium serve as protective barriers for the underlying layers of the cornea and conjunctiva. To allow comparison of data obtained in different studies assessing corneal staining, it is recommended that clinicians develop and adopt a universal standard protocol for this measure.

  3. CD 10 expression intensity in various grades and stages of urothelial carcinoma of urinary bladder.

    PubMed

    Atique, Muhammad; Abbasi, Muhammad Sajjad; Jamal, Shahid; Khadim, Muhammad Tahir; Akhtar, Farhan; Jamal, Nighat

    2014-05-01

    To evaluate CD10 expression in urothelial carcinoma of the urinary bladder and the association of immunohistochemical (IHC) CD10 expression intensity with grade and stage. Descriptive cross-sectional analytical study. Armed Forces Institute of Pathology, Rawalpindi, from January to December 2011. Fifty consecutive cases of urothelial bladder carcinomas, obtained through transurethral resections, were included in this study. Hematoxylin-eosin (HE) stained sections from each case were re-evaluated histopathologically according to WHO 2004 grading system. The TNM system was used for pathologic staging. On selected slides IHC CD10 marker was applied and a semiquantitative scoring for its expression based on the percentage of positive cells and intensity was performed. Data was entered and analysed on SPSS version 17. Fisher's exact test was used to compare grades, stages of urothelial carcinoma with CD 10 expression and age groups. P < 0.05 was taken as level of significance. Urothelial carcinoma was more common in males. The male to female ratio was 9:1. The older patients > 50 years had higher grade and stage as compared to the younger patients. All cases of high grade urothelial carcinoma showed higher positivity for CD 10. Twenty cases (86.95%) of high grade urothelial carcinoma were positive with +2 immunostaining while 3 cases (13.04 %) were positive with +1 staining. None of the tumors of stage pTa was positive for CD 10 expression. Of all patients with stage pT 1 tumor, 1 case (5.3%) was CD 10 negative and 17 cases (89.9%) were CD 10 positive having +1 staining with 5 - 50% staining and 1 case (5.3%) had +2 staining with more then 50% expression. Out of all patients with stage pT 2, no tumor was CD 10 negative, 3 (13.6%) patients were CD 10 positive with +1 staining and 19 (86.4%) with stage pT 2 tumor had stained positive with +2 staining. CD 10 expression was greater in high grade and invasive urothelial carcinomas; it may be associated with tumor progression

  4. Blockface histology with optical coherence tomography: a comparison with Nissl staining.

    PubMed

    Magnain, Caroline; Augustinack, Jean C; Reuter, Martin; Wachinger, Christian; Frosch, Matthew P; Ragan, Timothy; Akkin, Taner; Wedeen, Van J; Boas, David A; Fischl, Bruce

    2014-01-01

    Spectral domain optical coherence tomography (SD-OCT) is a high resolution imaging technique that generates excellent contrast based on intrinsic optical properties of the tissue, such as neurons and fibers. The SD-OCT data acquisition is performed directly on the tissue block, diminishing the need for cutting, mounting and staining. We utilized SD-OCT to visualize the laminar structure of the isocortex and compared cortical cytoarchitecture with the gold standard Nissl staining, both qualitatively and quantitatively. In histological processing, distortions routinely affect registration to the blockface image and prevent accurate 3D reconstruction of regions of tissue. We compared blockface registration to SD-OCT and Nissl, respectively, and found that SD-OCT-blockface registration was significantly more accurate than Nissl-blockface registration. Two independent observers manually labeled cortical laminae (e.g. III, IV and V) in SD-OCT images and Nissl stained sections. Our results show that OCT images exhibit sufficient contrast in the cortex to reliably differentiate the cortical layers. Furthermore, the modalities were compared with regard to cortical laminar organization and showed good agreement. Taken together, these SD-OCT results suggest that SD-OCT contains information comparable to standard histological stains such as Nissl in terms of distinguishing cortical layers and architectonic areas. Given these data, we propose that SD-OCT can be used to reliably generate 3D reconstructions of multiple cubic centimeters of cortex that can be used to accurately and semi-automatically perform standard histological analyses. © 2013.

  5. Blockface Histology with Optical Coherence Tomography: A Comparison with Nissl Staining

    PubMed Central

    Magnain, Caroline; Augustinack, Jean C.; Reuter, Martin; Wachinger, Christian; Frosch, Matthew P.; Ragan, Timothy; Akkin, Taner; Wedeen, Van J.; Boas, David A.; Fischl, Bruce

    2015-01-01

    Spectral domain optical coherence tomography (SD-OCT) is a high resolution imaging technique that generates excellent contrast based on intrinsic optical properties of the tissue, such as neurons and fibers. The SD-OCT data acquisition is performed directly on the tissue block, diminishing the need for cutting, mounting and staining. We utilized SD-OCT to visualize the laminar structure of the isocortex and compared cortical cytoarchitecture with the gold standard Nissl staining, both qualitatively and quantitatively. In histological processing, distortions routinely affect registration to the blockface image and prevent accurate 3D reconstruction of regions of tissue. We compared blockface registration to SD-OCT and Nissl, respectively, and found that SD-OCT-blockface registration was significantly more accurate than Nissl-blockface registration. Two independent observers manually labeled cortical laminae (e.g. III, IV and V) in SD-OCT images and Nissl stained sections. Our results show that OCT images exhibit sufficient contrast in the cortex to reliably differentiate the cortical layers. Furthermore, the modalities were compared with regard to cortical laminar organization and showed good agreement. Taken together, these SD-OCT results suggest that SD-OCT contains information comparable to standard histological stains such as Nissl in terms of distinguishing cortical layers and architectonic areas. Given these data, we propose that SD-OCT can be used to reliably generate 3D reconstructions of multiple cubic centimeters of cortex that can be used to accurately and semi-automatically perform standard histological analyses. PMID:24041872

  6. Photometric Application of the Gram Stain Method To Characterize Natural Bacterial Populations in Aquatic Environments

    PubMed Central

    Saida, H.; Ytow, N.; Seki, H.

    1998-01-01

    The Gram stain method was applied to the photometric characterization of aquatic bacterial populations with a charge-coupled device camera and an image analyzer. Escherichia coli and Bacillus subtilis were used as standards of typical gram-negative and gram-positive bacteria, respectively. A mounting agent to obtain clear images of Gram-stained bacteria on Nuclepore membrane filters was developed. The bacterial stainability by the Gram stain was indicated by the Gram stain index (GSI), which was applicable not only to the dichotomous classification of bacteria but also to the characterization of cell wall structure. The GSI spectra of natural bacterial populations in water with various levels of eutrophication showed a distinct profile, suggesting possible staining specificity that indicates the presence of a particular bacterial population in the aquatic environment. PMID:9464416

  7. The morphologic and immunohistochemical spectrum of papillary renal cell carcinoma: study including 132 cases with pure type 1 and type 2 morphology as well as tumors with overlapping features.

    PubMed

    Chevarie-Davis, Myriam; Riazalhosseini, Yasser; Arseneault, Madeleine; Aprikian, Armen; Kassouf, Wassim; Tanguay, Simon; Latour, Mathieu; Brimo, Fadi

    2014-07-01

    Papillary renal cell carcinomas (pRCC) are classically divided into type 1 and 2 tumors. However, many cases do not fulfill all the criteria for either type. We describe the clinical, morphologic, and immunohistochemical (IHC) features of 132 pRCCs to better characterize the frequency and nature of tumors with overlapping features. Cases were reviewed and classified; IHC evaluation of CK7, EMA, TopoIIα, napsin A, and AMACR was performed on 95 cases. The frequencies of type 1, type 2, and "overlapping" pRCC were 25%, 28%, and 47%, respectively. The 2 categories of "overlapping" tumors were: (1) cases with bland cuboidal cells but no basophilic cytoplasm (type A); and (2) cases with predominantly type 1 histology admixed with areas showing prominent nucleoli (type B). The pathologic stage of "overlapping" cases showed concordance with type 1 tumors. Using the 2 discriminatory markers (CK7, EMA), "type A" cases were similar to type 1. Although the high-nuclear grade areas of "type B" tumors showed some staining differences from their low-nuclear grade counterpart, their IHC profile was closer to type 1. Single nucleotide polymorphism array results, although preliminary and restricted to only 9 cases (3 with overlapping features), also seemed to confirm those findings. In conclusion, we demonstrate that variations in cytoplasmic quality and/or presence of high-grade nuclei in tumors otherwise displaying features of type 1 pRCCs are similar in stage and IHC profile those with classic type 1 histology, suggesting that their spectrum might be wider than originally described.

  8. Chromatic shifts in the fluorescence emitted by murine thymocytes stained with Hoechst 33342.

    PubMed

    Petersen, Timothy W; Ibrahim, Sherrif F; Diercks, Alan H; van den Engh, Ger

    2004-08-01

    Many methods in flow cytometry rely on staining DNA with a fluorescent dye to gauge DNA content. From the relative intensity of the fluorescence signature, one can then infer position in cell cycle, amount of DNA (i.e., for sperm selection), or, as in the case of flow karyotyping, to distinguish individual chromosomes. This work examines the staining of murine thymocytes with a common DNA dye, Hoechst 33342, to investigate nonlinearities in the florescence intensity as well as chromatic shifts. Murine thymocytes were stained with Hoechst 33342 and measured in a flow cytometer at two fluorescence emission bands. In other measurements, cells were stained at different dye concentrations, and then centrifuged. The supernatant was then used for a second round of staining to test the amount of dye uptake. Finally, to test for resonant energy transfer, we measured fluorescence anisotropy at two different wavelengths. The fluorescence of cells stained with Hoechst 33342 is a nonlinear process that shows an overall decrease in intensity with increased dye uptake, and spectral shift to the red. Along with the spectral shift of the fluorescence to the longer wavelengths, we document decreases in the fluorescence anisotropy that may indicate resonant energy transfer. At low concentrations, Hoechst 33342 binds to the minor groove of DNA and shows an increase in fluorescence and a blue shift upon binding. At higher concentrations, at which the dye molecules can no longer bind without overlapping, the blue fluorescence decreases and the red fluorescence increases until there is approximately one dye molecule per DNA base pair. The ratio of the blue fluorescence to the red fluorescence is an accurate indicator of the cellular dye concentration.

  9. [Improvement of Phi bodies stain and its clinical significance].

    PubMed

    Gong, Xu-Bo; Lu, Xing-Guo; Yan, Li-Juan; Xiao, Xi-Bin; Wu, Dong; Xu, Gen-Bo; Zhang, Xiao-Hong; Zhao, Xiao-Ying

    2009-02-01

    The aim of this study was to improve the dyeing method of hydroperoxidase (HPO), to analyze the morphologic features of Phi bodies and to evaluate the clinical application of this method. 128 bone marrow or peripheral blood smears from patients with myeloid and lymphoid malignancies were stained by improved HPO staining. The Phi bodies were observed with detection rate of Phi bodies in different leukemias. 69 acute myeloid leukemia (AML) specimens were chosen randomly, the positive rate and the number of Phi bodies between the improved HPO and POX stain based on the same substrate of 3, 3'diaminobenzidine were compared. The results showed that the shape of bundle-like Phi bodies was variable, long or short. while the nubbly Phi bodies often presented oval and smooth. Club-like Phi bodies were found in M(3). The detection rates of bundle-like Phi bodies in AML M(1)-M(5) were 42.9% (6/14), 83.3% (15/18), 92.0% (23/25), 52.3% (11/21), 33.3% (5/15) respectively, and those of nubbly Phi bodies were 28.6% (4/14), 66.7% (12/18), 11.1% (3/25), 33.3% (7/21), 20.0% (3/15) respectively. The detection rate of bundle-like Phi bodies in M(3) was significantly higher than that in (M(1) + M(2)) or (M(4) + M(5)) groups. The detection rate of nubbly Phi bodies in (M(1) + M(2)) group was higher than that in M(3) group. In conclusion, after improvement of staining method, the HPO stain becomes simple, the detection rate of Phi bodies is higher than that by the previous method, the positive granules are more obvious, and the results become stable. This improved method plays an important role in differentiating AML from ALL, subtyping AML, and evaluating the therapeutic results.

  10. Confocal mosaicing microscopy of basal-cell carcinomas ex vivo: progress in digital staining to simulate histology-like appearance

    NASA Astrophysics Data System (ADS)

    Bini, Jason; Spain, James; Nehal, Kishwer; Hazelwood, Vikki; DiMarzio, Charles; Rajadhyaksha, Milind

    2011-03-01

    Confocal mosaicing microscopy enables rapid imaging of large areas of fresh tissue, without the processing that is necessary for conventional histology. Using acridine orange (1 milliMolar, 20 seconds) to stain nuclei, basal cell carcinomas were detected in fluorescence confocal mosaics of Mohs surgical excisions with sensitivity of 96.6% and specificity of 89.2%. A possible barrier toward clinical acceptance is that confocal mosaics are based on a single mode of contrast and appear in grayscale, whereas histology is based on two (hematoxylin for nuclei, eosin for cellular cytoplasm and dermis) and appears purple-and-pink. Toward addressing this barrier, we report progress in developing a multispectral analytical model for digital staining: fluorescence confocal mosaics, which show only nuclei, are digitally stained purple and overlaid on reflectance confocal mosaics, which show only cellular cytoplasm and dermis, and digitally stained pink, to mimic the appearance of histology. Comparison of digitally stained confocal mosaics by our Mohs surgeon to the corresponding Mohs histology shows good correlation for normal and tumor detail. Digitally stained confocal mosaicing microscopy may allow direct examination of freshly excised tissue and serve as an adjunct for rapid pathology at-the-bedside.

  11. [Histochemical stains for minerals by hematoxylin-lake method].

    PubMed

    Miyagawa, Makoto

    2013-04-01

    The present study was undertaken to establish the experimental animal model by histological staining methods for minerals. After intraperitoneal injections of minerals, precipitates deposited on the surface of the liver. Liver tissues were fixed in paraformaldehyde, embedded in paraffin and cut into thin sections which were used as minerals containing standard section. Several reagents for histological stains and spectrophotometry for minerals were applied in both test-tube experiments and stainings of tissue sections to test for minerals. Hematoxylin-lake was found of capable of staining minerals in tissue. A simple technique used was described for light microscopic detection of minerals.

  12. Improved Whole-Blood-Staining Device

    NASA Technical Reports Server (NTRS)

    Sams, Clarence F.; Crucian, Brian; Paul, Bonnie; Melton, Shannon; Guess, Terry

    2012-01-01

    Dramatic improvements have been made in NASA s Whole Blood Staining Device (WBSD) since it was last described in "Whole-Blood-Staining Device," NASA Tech Briefs, Vol. 23, No. 10 (October 1999), page 64. The new system has a longer shelf life, a simpler and more effective operational procedure, improved interface with instrumentation, and shorter processing time. More specifically, the improvements have targeted bag and locking clip materials, sampling ports, and air pocket prevention. The WBSD stains whole blood collected during spaceflight for subsequent flow cytometric analysis. In short, the main device stains white blood cells by use of monoclonal antibodies conjugated to various fluorochromes, followed by lysing and fixing of the cells by use of a commercial reagent that has been diluted according to NASA safety standards. This system is compact, robust, and does not require electric power, precise mixing, or precise incubation times. Figure 1 depicts the present improved version for staining applications, which is a poly(tetrafluoroethylene) bag with a Luer-lock port and plastic locking clips. An InterLink (or equivalent) intravenous- injection port screws into the Luer-lock port. The inflatable/collapsible nature of the bag facilitates loading and helps to minimize the amount of air trapped in the fully loaded bag. Some additional uses have been identified for the device beyond whole blood staining. The WBSD has been configured for functional assays that require culture of live cells by housing sterile culture media, mitogens, and fixatives prior to use [Figure 2(a)]. Simple injection of whole blood allows cell-stimulation culture to be performed in reduced gravity conditions, and product stabilization prior to storage, while protecting astronauts from liquid biohazardous materials. Also, the improved WBSD has reconstituted powdered injectable antibiotics by mixing them with diluent liquids [Figure 2(b)]. Although such mixing can readily be performed on

  13. Infrared fluorescence microscopy of stained tissues: principles and technic.

    PubMed

    Puchtler, H; Meloan, S N; Paschal, L D

    1980-01-01

    Infrared photomicrography was used extensively from 1927 to the 1940's, but received little attention during the last decades. However, studies of infrared fluorescence of stained sections could not be found in the accessible literature. Ramsley (1968) published quantitative data on infrared fluorescence of approximately 250 dyes bound to textile fibers. The intensity of infrared fluorescence of many dyes varied widely with the substrate. It was therefore deemed of interest to determine whether or not similar differences in infrared fluorescence may occur when dyes are bound to histochemically distinct tissue structures. Myofibrils and collagens stained with triarylmethane dyes were chosen as test objects. Kodak infrared cut-off filter No. 301 and Wratten filter #16 were used as exciter filters to remove infrared and UV-blue and the light of a xenon lamp. Wratten filter #70 and #89B were employed as barrier filters. Infrared radiation was recorded with Kodak Ektachrome infrared film. To facilitate correlation of infrared fluorescence patterns with visible images, tissues were photographed also with conventional color film. Stained myofibrils, e.g. in myoepithelium, smooth and striated muscle emitted strong infrared fluorescence; collagen showed little or no fluorescence. Barrier filter Wratten #70 permitted simultaneous demonstration of infrared fluorescence and of non-fluorescent structures and thus facilitated histopathological studies. Preliminary findings indicate decrease or loss of infrared fluorescence of stained muscle fibers in various lesions, e.g. myocardial infarction, Duchenne-type muscular dystrophy.

  14. Platinum blue as an alternative to uranyl acetate for staining in transmission electron microscopy.

    PubMed

    Inaga, Sumire; Katsumoto, Tetsuo; Tanaka, Keiichi; Kameie, Toshio; Nakane, Hironobu; Naguro, Tomonori

    2007-04-01

    This paper introduces an aqueous solution of platinum blue (Pt-blue) as an alternative to uranyl acetate (UA) for staining in transmission electron microscopy (TEM). Pt-blue was prepared from a reaction of cis-dichlorodiamine-platinum (II) (cis-platin) with thymidine. When Pt-blue was dried on a microgrid and observed by TEM it showed a uniform appearance with tiny particles less than 1 nm in diameter. The effect of Pt-blue as an electron stain was then examined not only for positive staining of conventional ultrathin resin sections and counterstaining of post-embedding immuno-electron microscopy but also for negative staining. In ultrathin sections of the rat liver and renal glomerulus, Pt-blue provided good contrast images, especially in double staining combined with a lead stain (Pb). Almost all cell organelles were clearly observed with high contrast in these sections. Glycogen granules in the hepatic parenchymal cells were particularly electron dense in Pt-blue stained sections compared with those treated with UA. In longitudinal and transverse sections of budding influenza A viruses, a specific arrangement of rod-like structures, which correspond to the ribonucleoprotein complexes, was clearly shown in each virion stained with Pt-blue and Pb. When post-embedding immunoelectron microscopy was performed in ultrathin sections of HeLa cells embedded in Lowicryl K4M, the localization of Ki-67 protein was sufficiently detected even after Pt-blue and Pb staining. The present study also revealed that Pt-blue could be used for the negative staining of E. coli, allowing the visualization of a flagellum. These findings indicate that Pt-blue is a useful, safe, and easily obtainable electron stain that is an alternative to UA for TEM preparations.

  15. Candida, fluorescent stain (image)

    MedlinePlus

    ... a fluorescent stain of Candida. Candida is a yeast (fungus) that causes mild disease, but in immunocompromised individuals it may cause life-threatening illness. (Image courtesy of the Centers for ...

  16. Automated single-slide staining device

    NASA Technical Reports Server (NTRS)

    Wilkins, J. R.; Mills, S. M. (Inventor)

    1977-01-01

    A simple apparatus and method is disclosed for making individual single Gram stains on bacteria inoculated slides to assist in classifying bacteria in the laboratory as Gram-positive or Gram-negative. The apparatus involves positioning a single inoculated slide in a stationary position and thereafter automatically and sequentially flooding the slide with increments of a primary stain, a mordant, a decolorizer, a counterstain and a wash solution in a sequential manner without the individual lab technician touching the slide and with minimum danger of contamination thereof from other slides.

  17. Rapid contrast evaluation method based on affinity beads and backscattered electron imaging for the screening of electron stains.

    PubMed

    Kaku, Hiroki; Inoue, Kanako; Muranaka, Yoshinori; Park, Pyoyun; Ikeda, Kenichi

    2015-10-01

    Uranyl salts are toxic and radioactive; therefore, several studies have been conducted to screen for substitutes of electron stains. In this regard, the contrast evaluation process is time consuming and the results obtained are inconsistent. In this study, we developed a novel contrast evaluation method using affinity beads and a backscattered electron image (BSEI), obtained using scanning electron microscopy. The contrast ratios of BSEI in each electron stain treatment were correlated with those of transmission electron microscopic images. The affinity beads bound to cell components independently. Protein and DNA samples were enhanced by image contrast treated with electron stains; however, this was not observed for sugars. Protein-conjugated beads showed an additive effect of image contrast when double-stained with lead. However, additive effect of double staining was not observed in DNA-conjugated beads. The varying chemical properties of oligopeptides showed differences in image contrast when treated with each electron stain. This BSEI-based evaluation method not only enables screening for alternate electron stains, but also helps analyze the underlying mechanisms of electron staining of cellular structures. © The Author 2015. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  18. Detection of an ALK Fusion in Colorectal Carcinoma by Hybrid Capture-Based Assay of Circulating Tumor DNA.

    PubMed

    Lai, Andrea Z; Schrock, Alexa B; Erlich, Rachel L; Ross, Jeffrey S; Miller, Vincent A; Yakirevich, Evgeny; Ali, Siraj M; Braiteh, Fadi

    2017-07-01

    ALK rearrangements have been observed in 0.05%-2.5% of patients with colorectal cancers (CRCs) and are predicted to be oncogenic drivers largely mutually exclusive of KRAS, NRAS, or BRAF alterations. Here we present the case of a patient with metastatic CRC who was treatment naïve at the time of molecular testing. Initial ALK immunohistochemistry (IHC) staining was negative, but parallel genomic profiling of both circulating tumor DNA (ctDNA) and tissue using similar hybrid capture-based assays each identified an identical STRN-ALK fusion. Subsequent ALK IHC staining of the same specimens was positive, suggesting that the initial result was a false negative. This report is the first instance of an ALK fusion in CRC detected using a ctDNA assay. Current guidelines for colorectal cancer (CRC) only recommend genomic assessment of KRAS, NRAS, BRAF, and microsatellite instability (MSI) status. ALK rearrangements are rare in CRC, but patients with activating ALK fusions have responded to targeted therapies ALK rearrangements can be detected by genomic profiling of ctDNA from blood or tissue, and this methodology may be informative in cases where immunohistochemistry (IHC) or other standard testing is negative. © AlphaMed Press 2017.

  19. Microscopic diagnosis of dysbacteriosis in stained vaginal smears in clinical practice.

    PubMed

    Verbruggen, Banut-Sabine M; Boon, Mathilde E; Melkerl, Peter; van Haaften, Maarten; Heintz, A Peter M

    2006-10-01

    Dysbacteriosis is a microscopical diagnosis. In women with dysbacteriosis, an overgrowth of coccoid bacteria and almost a complete absence of lactobacilli are observed in the (stained) vaginal smear. The aim of this study was to determine the accuracy of this microscopic diagnosis in clinical practice. The analysis concerned 342 consecutive cases in which the microscopy of the stained smears was performed by general practitioners trained in diagnosing dysbacteriosis. These smears were sent to the pathologist for confirmation of the microscopical diagnosis of the clinician. The cytological diagnoses of the pathologist, sometimes performed on restained slides when the quality of the staining was substandard, were considered as the "gold standard." In 92 of the 342 cases, dysbacteriosis was unequivocally established by the pathologist. Sensitivity and specificity of the microscopical diagnoses of the clinicians were 40% and 85%, respectively. There were 37 false-positive and 54 false-negative diagnoses of dysbacteriosis rendered by the clinicians. The most frequent reason for a false-negative diagnosis was an excess of lactobacilli in the smear. This study shows that even in stained smears it is difficult for clinicians to render a correct evaluation of the status of the vaginal flora.

  20. Problems in aerial application : histochemistry of Weil stain on liver.

    DOT National Transportation Integrated Search

    1966-11-01

    By use of histochemical blocking and extraction procedures, it was possible to show that the cytoplasmic compound to which the Weil stain attaches is a lipid containing a secondary amine. It is suggested that the compound could be further characteriz...

  1. Frequency of satellite association of human chromosomes is correlated with amount of Ag-staining of the nucleolus organizer region.

    PubMed Central

    Miller, D A; Tantravahi, R; Dev, V G; Miller, O J

    1977-01-01

    Methaphase chromosomes from karyotypically normal adult humans (three males, six females) and one male with a 13p - chromosome were stained by quinacrine and then by the Ag-AS silver staining method to reveal nucleolus organizer regions (NORs). Each person had a characteristic number of Ag-stained chromosomes per cell, always fewer than 10. Determination of the mean Ag-size of each chromosome showed that each of the 10 individuals had a unique distribution of Ag-stain. Within each individual, there was some variation from cell to cell in the number of acrocentric chromosomes that were Ag-stained; this was not random, and the same chromosomes (those that had at most a small amount of Ag-stain) tended to be unstained in every cell. Satellite associations were scored on the same cells. Chromosomes that had no Ag-stain were involved in satellite association less than 20% as often as those that had some Ag-stain. Chromosomes that had a small amount of Ag-stain were involved in association about 50% as often as those that had a large amount of stain. Regression analysis of the 50 (of a total of 100) acrocentric chromosomes which could be individually identified by quinacrine markers showed that the frequency with which a chromosome was involved in satellite association was strongly correlated with the amount of Ag-stained material in the NOR. Images Fig. 1 Fig. 3 PMID:70995

  2. Temporal variation of VOC emission from solvent and water based wood stains

    NASA Astrophysics Data System (ADS)

    de Gennaro, Gianluigi; Loiotile, Annamaria Demarinis; Fracchiolla, Roberta; Palmisani, Jolanda; Saracino, Maria Rosaria; Tutino, Maria

    2015-08-01

    Solvent- and water-based wood stains were monitored using a small test emission chamber in order to characterize their emission profiles in terms of Total and individual VOCs. The study of concentration-time profiles of individual VOCs enabled to identify the compounds emitted at higher concentration for each type of stain, to examine their decay curve and finally to estimate the concentration in a reference room. The solvent-based wood stain was characterized by the highest Total VOCs emission level (5.7 mg/m3) that decreased over time more slowly than those related to water-based ones. The same finding was observed for the main detected compounds: Benzene, Toluene, Ethylbenzene, Xylenes, Styrene, alpha-Pinene and Camphene. On the other hand, the highest level of Limonene was emitted by a water-based wood stain. However, the concentration-time profile showed that water-based product was characterized by a remarkable reduction of the time of maximum and minimum emission: Limonene concentration reached the minimum concentration in about half the time compared to the solvent-based product. According to AgBB evaluation scheme, only one of the investigated water-based wood stains can be classified as a low-emitting product whose use may not determine any potential adverse effect on human health.

  3. Structure-Preserving Color Normalization and Sparse Stain Separation for Histological Images.

    PubMed

    Vahadane, Abhishek; Peng, Tingying; Sethi, Amit; Albarqouni, Shadi; Wang, Lichao; Baust, Maximilian; Steiger, Katja; Schlitter, Anna Melissa; Esposito, Irene; Navab, Nassir

    2016-08-01

    Staining and scanning of tissue samples for microscopic examination is fraught with undesirable color variations arising from differences in raw materials and manufacturing techniques of stain vendors, staining protocols of labs, and color responses of digital scanners. When comparing tissue samples, color normalization and stain separation of the tissue images can be helpful for both pathologists and software. Techniques that are used for natural images fail to utilize structural properties of stained tissue samples and produce undesirable color distortions. The stain concentration cannot be negative. Tissue samples are stained with only a few stains and most tissue regions are characterized by at most one effective stain. We model these physical phenomena that define the tissue structure by first decomposing images in an unsupervised manner into stain density maps that are sparse and non-negative. For a given image, we combine its stain density maps with stain color basis of a pathologist-preferred target image, thus altering only its color while preserving its structure described by the maps. Stain density correlation with ground truth and preference by pathologists were higher for images normalized using our method when compared to other alternatives. We also propose a computationally faster extension of this technique for large whole-slide images that selects an appropriate patch sample instead of using the entire image to compute the stain color basis.

  4. Methods And Compositions For Chromosome-Specific Staining

    DOEpatents

    Gray, Joe W.; Pinkel, Daniel

    2003-08-19

    Methods and compositions for staining based upon nucleic acid sequence that employ nucleic acid probes are provided. Said methods produce staining patterns that can be tailored for specific cytogenetic analyses. Said probes are appropriate for in situ hybridization and stain both interphase and metaphase chromosomal material with reliable signals. The nucleic acid probes are typically of a complexity greater than 50 kb, the complexity depending upon the cytogenetic application. Methods are provided to disable the hybridization capacity of shared, high copy repetitive sequences and/or remove such sequences to provide for useful contrast. Still further methods are provided to produce chromosome-specific staining reagents which are made specific to the targeted chromosomal material, which can be one or more whole chromosomes, one or more regions on one or more chromosomes, subsets of chromosomes and/or the entire genome. Probes and test kits are provided for use in tumor cytogenetics, in the detection of disease related loci, in analysis of structural abnormalities, such as translocations, and for biological dosimetry. Further, methods and prenatal test kits are provided to stain targeted chromosomal material of fetal cells, including fetal cells obtained from maternal blood. Still further, the invention provides for automated means to detect and analyse chromosomal abnormalities.

  5. Using microabrasive material to remove fluorosis stains.

    PubMed

    Allen, Kenneth; Agosta, Claudine; Estafan, Denise

    2004-03-01

    Increased public access to fluoride has decreased the prevalence of caries and increased the prevalence of fluorosis staining. This article provides a case report involving a conservative method of removing fluorosis stain, as well as describes an in vitro test of the method. A healthy man sought treatment at New York University College of Dentistry for removal of severe, dark brown fluorosis staining on his anterior teeth. To remove the stain, the treating clinician used a microabrasive material, which leaves enamel intact, instead of a tooth-whitening agent, which requires removal of all affected enamel. To demonstrate that enamel structure is not disturbed by the microabrasive material, the authors performed a study using scanning electron microscopy, or SEM. They viewed enamel structure under SEM at x1,000 magnification. They viewed untreated microabraded enamel and compared it with enamel that had been treated for 20 seconds with 37 percent phosphoric acid. An etch pattern was not discernible on the tooth treated with the microabrasive material. The enamel prisms remained intact and the cores were not exposed. Microabrasion removes intrinsic fluorosis stain effectively while protecting enamel. In this case, an enamel shade of brown not in the range of any tooth color shade guide was reduced.

  6. Prediction of late distant recurrence in patients with oestrogen-receptor-positive breast cancer: a prospective comparison of the breast-cancer index (BCI) assay, 21-gene recurrence score, and IHC4 in the TransATAC study population.

    PubMed

    Sgroi, Dennis C; Sestak, Ivana; Cuzick, Jack; Zhang, Yi; Schnabel, Catherine A; Schroeder, Brock; Erlander, Mark G; Dunbier, Anita; Sidhu, Kally; Lopez-Knowles, Elena; Goss, Paul E; Dowsett, Mitch

    2013-10-01

    Biomarkers to improve the risk-benefit of extended adjuvant endocrine therapy for late recurrence in patients with oestrogen-receptor-positive breast cancer would be clinically valuable. We compared the prognostic ability of the breast-cancer index (BCI) assay, 21-gene recurrence score (Oncotype DX), and an immunohistochemical prognostic model (IHC4) for both early and late recurrence in patients with oestrogen-receptor-positive, node-negative (N0) disease who took part in the Arimidex, Tamoxifen, Alone or in Combination (ATAC) clinical trial. In this prospective comparison study, we obtained archival tumour blocks from the TransATAC tissue bank from all postmenopausal patients with oestrogen-receptor-positive breast cancer from whom the 21-gene recurrence score and IHC4 values had already been derived. We did BCI analysis in matched samples with sufficient residual RNA using two BCI models-cubic (BCI-C) and linear (BCI-L)-using previously validated cutoffs. We assessed prognostic ability of BCI for distant recurrence over 10 years (the primary endpoint) and compared it with that of the 21-gene recurrence score and IHC4. We also tested the ability of the assays to predict early (0-5 years) and late (5-10 years) distant recurrence. To assess the ability of the biomarkers to predict recurrence beyond standard clinicopathological variables, we calculated the change in the likelihood-ratio χ(2) (LR-Δχ(2)) from Cox proportional hazards models. Suitable tissue was available from 665 patients with oestrogen-receptor-positive, N0 breast cancer for BCI analysis. The primary analysis showed significant differences in risk of distant recurrence over 10 years in the categorical BCI-C risk groups (p<0·0001) with 6·8% (95% CI 4·4-10·0) of patients in the low-risk group, 17·3% (12·0-24·7) in the intermediate group, and 22·2% (15·3-31·5) in the high-risk group having distant recurrence. The secondary analysis showed that BCI-L was a much stronger predictor for overall

  7. The development of fluorescence turn-on probe for Al(III) sensing and live cell nucleus-nucleoli staining

    NASA Astrophysics Data System (ADS)

    Saini, Anoop Kumar; Sharma, Vinay; Mathur, Pradeep; Shaikh, Mobin M.

    2016-10-01

    The morphology of nucleus and nucleolus is powerful indicator of physiological and pathological conditions. The specific staining of nucleolus recently gained much attention due to the limited and expensive availability of the only existing stain “SYTO RNA-Select”. Here, a new multifunctional salen type ligand (L1) and its Al3+ complex (1) are designed and synthesized. L1 acts as a chemosensor for Al3+ whereas 1 demonstrates specific staining of nucleus as well as nucleoli. The binding of 1 with nucleic acid is probed by DNase and RNase digestion in stained cells. 1 shows an excellent photostability, which is a limitation for existing nucleus stains during long term observations. 1 is assumed to be a potential candidate as an alternative to expensive commercial dyes for nucleus and nucleoli staining.

  8. The development of fluorescence turn-on probe for Al(III) sensing and live cell nucleus-nucleoli staining.

    PubMed

    Saini, Anoop Kumar; Sharma, Vinay; Mathur, Pradeep; Shaikh, Mobin M

    2016-10-10

    The morphology of nucleus and nucleolus is powerful indicator of physiological and pathological conditions. The specific staining of nucleolus recently gained much attention due to the limited and expensive availability of the only existing stain "SYTO RNA-Select". Here, a new multifunctional salen type ligand (L 1 ) and its Al 3+ complex (1) are designed and synthesized. L 1 acts as a chemosensor for Al 3+ whereas 1 demonstrates specific staining of nucleus as well as nucleoli. The binding of 1 with nucleic acid is probed by DNase and RNase digestion in stained cells. 1 shows an excellent photostability, which is a limitation for existing nucleus stains during long term observations. 1 is assumed to be a potential candidate as an alternative to expensive commercial dyes for nucleus and nucleoli staining.

  9. Distinction of Invasive Carcinoma Derived From Intraductal Papillary Mucinous Neoplasms From Concomitant Ductal Adenocarcinoma of the Pancreas Using Molecular Biomarkers.

    PubMed

    Tamura, Koji; Ohtsuka, Takao; Date, Kenjiro; Fujimoto, Takaaki; Matsunaga, Taketo; Kimura, Hideyo; Watanabe, Yusuke; Miyazaki, Tetsuyuki; Ohuchida, Kenoki; Takahata, Shunichi; Ishigami, Kousei; Oda, Yoshinao; Mizumoto, Kazuhiro; Nakamura, Masafumi; Tanaka, Masao

    2016-07-01

    To clarify the usefulness of molecular biomarkers for distinguishing invasive carcinoma derived from intraductal papillary mucinous neoplasms (IPMNs [Inv-IPMN]) from concomitant pancreatic ductal adenocarcinoma (PDAC). Data from 19 patients with resected concomitant PDAC were retrospectively reviewed. KRAS/GNAS mutations and immunohistochemical (IHC) expression of p53 and p16/CDKN2A were assessed in both IPMN and distinct PDAC. As controls, KRAS/GNAS mutations and IHC labeling were assessed between invasive and noninvasive components in 1 lesion of 22 independent patients. KRAS/GNAS mutation status of invasive and noninvasive components in Inv-IPMN was consistent in 18 (86%) of 21 patients. Conversely, mutational patterns in IPMN and distinct PDAC in the same pancreas differed from each other in 17 (89%) of 19. There were 10 (53%) and 8 (42%) of 19 patients who showed the same p53 and p16/CDKN2A staining between concomitant PDAC and distinct IPMN. In the Inv-IPMN cohort, 19 (86%) of 22 patients showed the same IHC expression pattern between the noninvasive and invasive components. It may be possible to distinguish Inv-IPMN from concomitant PDAC by assessing these molecular biomarkers. More precise distinction of Inv-IPMN and concomitant PDAC will lead to adequate recognition of the natural history of IPMNs and hence optimal management.

  10. A novel, modernized Golgi-Cox stain optimized for CLARITY cleared tissue.

    PubMed

    Kassem, Mustafa S; Fok, Sandra Y Y; Smith, Kristie L; Kuligowski, Michael; Balleine, Bernard W

    2018-01-15

    High resolution neuronal information is extraordinarily useful in understanding the brain's functionality. The development of the Golgi-Cox stain allowed observation of the neuron in its entirety with unrivalled detail. Tissue clearing techniques, e.g., CLARITY and CUBIC, provide the potential to observe entire neuronal circuits intact within tissue and without previous restrictions with regard to section thickness. Here we describe an improved Golgi-Cox stain method, optimised for use with CLARITY and CUBIC that can be used in both fresh and fixed tissue. Using this method, we were able to observe neurons in their entirety within a fraction of the time traditionally taken to clear tissue (48h). We were also able to show for the first-time that Golgi stained tissue is fluorescent when visualized using a multi-photon microscope, allowing us to image synaptic spines with a detail previously unachievable. These novel methods provide cheap and easy to use techniques to investigate the morphology of cellular processes in the brain at a new-found depth, speed, utility and detail, without previous restrictions of time, tissue type and section thickness. This is the first application of a Golgi-Cox stain to cleared brain tissue, it is investigated and discussed in detail, describing different methodologies that may be used, a comparison between the different clearing techniques and lastly the novel interaction of these techniques with this ultra-rapid stain. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. [Companion diagnostics "POTELIGEO TEST IHC/FCM" used with "POTELIGEO" (mogamulizumab) for adult T-cell leukemia-lymphoma (ATL) treatment].

    PubMed

    Goami, Takeshi

    2014-05-01

    Personalized medicine offers the best treatment for individual patients, it is important for an IVD manufacturer to develop companion diagnostics in parallel with the development of new drugs through close cooperation with drug companies, and supply diagnostics companies with new drugs for physicians and patients. We received approval for a premarket approval application (PMA) for two in vitro diagnostic ("IVD") reagents, POTELIGEO TEST IHC and POTELIGEO TEST FCM ("POTELIGEO TEST"), in March 2012, and subsequently launched POTELIGEO TEST in May 2012. POTELIGEO TEST is a companion diagnostic used with POTELIGEO for which Kyowa Hakko Kirin has a new drug application (NDA) that was approved in March 2012, and is designed to help physicians identify appropriate subpopulations of adult T-cell leukemia-lymphoma(ATL) patients who are most likely to respond to POTELIGEO 20 mg (mogamulizumab) Injection ("POTELIGEO").

  12. 7 CFR 28.441 - Strict Middling Yellow Stained Color.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Strict Middling Yellow Stained Color. 28.441 Section... Strict Middling Yellow Stained Color. Strict Middling Yellow Stained Color is color which is deeper than that of Strict Middling Tinged Color. [57 FR 34498, Aug. 5, 1992] ...

  13. 7 CFR 28.441 - Strict Middling Yellow Stained Color.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Strict Middling Yellow Stained Color. 28.441 Section... Strict Middling Yellow Stained Color. Strict Middling Yellow Stained Color is color which is deeper than that of Strict Middling Tinged Color. [57 FR 34498, Aug. 5, 1992] ...

  14. 7 CFR 28.441 - Strict Middling Yellow Stained Color.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Strict Middling Yellow Stained Color. 28.441 Section... Strict Middling Yellow Stained Color. Strict Middling Yellow Stained Color is color which is deeper than that of Strict Middling Tinged Color. [57 FR 34498, Aug. 5, 1992] ...

  15. 7 CFR 28.441 - Strict Middling Yellow Stained Color.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Strict Middling Yellow Stained Color. 28.441 Section... Strict Middling Yellow Stained Color. Strict Middling Yellow Stained Color is color which is deeper than that of Strict Middling Tinged Color. [57 FR 34498, Aug. 5, 1992] ...

  16. 7 CFR 28.441 - Strict Middling Yellow Stained Color.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Strict Middling Yellow Stained Color. 28.441 Section... Strict Middling Yellow Stained Color. Strict Middling Yellow Stained Color is color which is deeper than that of Strict Middling Tinged Color. [57 FR 34498, Aug. 5, 1992] ...

  17. Post-staining electroblotting for efficient and reliable peptide blotting.

    PubMed

    Lee, Der-Yen; Chang, Geen-Dong

    2015-01-01

    Post-staining electroblotting has been previously described to transfer Coomassie blue-stained proteins from polyacrylamide gel onto polyvinylidene difluoride (PVDF) membranes. Actually, stained peptides can also be efficiently and reliably transferred. Because of selective staining procedures for peptides and increased retention of stained peptides on the membrane, even peptides with molecular masses less than 2 kDa such as bacitracin and granuliberin R are transferred with satisfactory results. For comparison, post-staining electroblotting is about 16-fold more sensitive than the conventional electroblotting for visualization of insulin on the membrane. Therefore, the peptide blots become practicable and more accessible to further applications, e.g., blot overlay detection or immunoblotting analysis. In addition, the efficiency of peptide transfer is favorable for N-terminal sequence analysis. With this method, peptide blotting can be normalized for further analysis such as blot overlay assay, immunoblotting, and N-terminal sequencing for identification of peptide in crude or partially purified samples.

  18. Gram staining in the diagnosis of acute septic arthritis.

    PubMed

    Faraj, A A; Omonbude, O D; Godwin, P

    2002-10-01

    This study aimed at determining the sensitivity and specificity of Gram staining of synovial fluid as a diagnostic tool in acute septic arthritis. A retrospective study was made of 22 patients who had arthroscopic lavage following a provisional diagnosis of acute septic arthritis of the knee joint. Gram stains and cultures of the knee aspirates were compared with the clinical and laboratory parameters, to evaluate their usefulness in diagnosing acute arthritis. All patients who had septic arthritis had pain, swelling and limitation of movement. CRP was elevated in 90% of patients. The incidence of elevated white blood cell count was higher in the group of patients with a positive Gram stain study (60%) as compared to patients with a negative Gram stain study (33%). Gram staining sensitivity was 45%. Its specificity was however 100%. Gram staining is an unreliable tool in early decision making in patients requiring urgent surgical drainage and washout.

  19. A Versatile Giemsa Protocol for Permanent Nuclear Staining of Fungi

    Treesearch

    A. Dan Wilson

    1992-01-01

    A variety of cytological stains and staining procedures including Giemsa-HCL, acetic-or-cein, propionic-carmine, iron haema-toxylin, safranin O, aniline blue or trypan blue, toluidine blue and basic fuchsin or Feulgen stain have been used to investigate the nuclear condition of reproductive and somatic structures of fungi. Fluorescent stains such as acriflavin acridine...

  20. A Strategy for Helicobacter Immunohistochemistry Utilization in Pediatric Practice:  Insights From Morphologic and Cost-Benefit Analyses.

    PubMed

    Conces, Miriam R; Arnold, Christina A; Baker, Peter B; Carter, Christopher M; Fung, Bonita; Prasad, Vinay; Arnold, Michael A

    2016-11-01

    Recent studies in adults have examined the utility of immunohistochemistry (IHC) in detecting Helicobacter in gastric biopsy specimens and reached differing conclusions. Dedicated cost-benefit analysis of Helicobacter IHC in pediatric gastric biopsy specimens has not been performed. From 1,955 pediatric gastric biopsies in a 1-year period, we identified 63 Helicobacter -positive and 120 Helicobacter -negative biopsy specimens. All cases were scored according to the Updated Sydney System for the severity of inflammation. We observed that pediatric Helicobacter infection was significantly associated with germinal center formation, active inflammation, oxyntic mucosa with moderate to severe chronic inflammation, and antral mucosa with any chronic inflammation, exclusive of mild and superficial chronic inflammation. At least one associated pattern was seen in each Helicobacter -positive biopsy specimen. In comparison with adults, pediatric Helicobacter -positive biopsy specimens are more likely to lack acute inflammation and more likely to show moderate to marked chronic inflammation. We recommend performing Helicobacter IHC on pediatric gastric biopsy specimens with any of the above inflammatory patterns. This approach can sensitively identify pediatric patients with Helicobacter gastritis, limit IHC staining to approximately 30% of all gastric biopsy specimens, and reduce costs by up to $55,306.90 per 1,000 biopsy specimens. © American Society for Clinical Pathology, 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  1. Contact lens-induced circumlimbal staining in silicone hydrogel contact lenses worn on a daily wear basis.

    PubMed

    Maïssa, Cécile; Guillon, Michel; Garofalo, Renee J

    2012-01-01

    The principal objective of the study was to measure the conjunctival staining produced in the circumlimbal region by silicone hydrogel contact lenses with different edge designs. The secondary objective was to investigate the association between circumlimbal staining and comfort. Four silicone hydrogel contact lenses: ACUVUE OASYS (knife edge design), AIR OPTIX, Biofinity (chisel edge rounded edge combination), and PureVision (rounded edge design), and 1 hydrogel contact lens, ACUVUE 2 (knife edge design), were tested. The study was conducted on a cohort population of 27 established soft contact lens wearers, who wore each contact lens type, in a random order, for a period of 10 (±2) days. Circumlimbal staining was measured in a double-masked fashion through image analysis of digital photographs of lissamine green taken under controlled experimental conditions. The results obtained showed that contact lens edge design was the primary factor controlling circumlimbal staining for silicone hydrogel lenses: a rounded edge away from the ocular surface produced the lowest staining (average, 0.19%) and a knife edge in close apposition to the ocular surface produced the highest staining (average, 1.34%). Contact lens material rigidity was also identified to affect circumlimbal staining and an inverse association between circumlimbal staining and contact lens comfort was demonstrated: the rounded edge design produced the lowest comfort (72 of 100) and the knife edge design produced the highest (87 out of 100). Soft contact lens wear induces circumlimbal staining, the level of staining being influenced by the contact lens edge design. However, high level of circumlimbal staining is not associated with decreased comfort.

  2. Western Blot of Stained Proteins from Dried Polyacrylamide Gels

    NASA Technical Reports Server (NTRS)

    Gruber, Claudia; Stan-Lotter, Helga

    1996-01-01

    Western blotting of proteins is customarily performed following their separation on polyacrylamide gels, either prior to staining (1) or, as recently reported, following staining (2). We describe here Western blotting with stained gels, which had been dried and some of which had been stored for years. This procedure permits immunological analysis of proteins, to which antisera may have become available only later, or where the application of newly developed sensitive detection methods is desired. Once rehydration of the gels is achieved, proteins can be-transferred to blotting membranes by any appropriate protocol. Proteins stained with Coomassie Blue have to be detected with a non-chromogenic method, such as the film-based enhanced chemiluminescence (ECL)2) procedure (3). Silver stained proteins, which transfer in the colorless form, may be visualized by any detection method, although, because of the usually very low amounts of proteins, detection by ECL is preferable. Blotting of stained proteins from rehydrated gels is as rapid and as quantitative as from freshly prepared gels, in contrast to blotting from wet stained gels, which requires extensive washing and results in low transfer efficiency (2). Together with a photographic record of the gel pattern, unambiguous identification of immunoreactive proteins from complex mixtures is possible. Some further applications of this work are discussed.

  3. [Usefulness of sputum Gram staining in community-acquired pneumonia].

    PubMed

    Sato, Tadashi; Aoshima, Masahiro; Ohmagari, Norio; Tada, Hiroshi; Chohnabayashi, Naohiko

    2002-07-01

    To evaluate the usefulness of sputum gram staining in community-acquired pneumonia (CAP), we reviewed 144 cases requiring hospitalization in the last 4 years. The sensitivity was 75.5%, specificity 68.2%, positive predictive value 74.1%, negative predictive value 69.8%, positive likelihood ratio 2.37, negative likelihood ratio 0.36 and accuracy 72.2% in 97 cases. Both sputum gram staining and culture were performed. Concerning bacterial pneumonia (65 cases), we compared the Gram staining group (n = 33), which received initial antibiotic treatment, based on sputum gram staining with the Empiric group (n = 32) that received antibiotics empirically. The success rates of the initial antibiotic treatment were 87.9% vs. 78.1% (P = 0.473); mean hospitalization periods were 9.67 vs. 11.75 days (P = 0.053); and periods of intravenous therapy were 6.73 vs. 7.91 days (P = 0.044), respectively. As for initial treatment, penicillins were used in the Gram staining group more frequently (P < 0.01). We conclude that sputum gram staining is useful for the shortening of the treatment period and the appropriate selection of initial antibiotics in bacterial pneumonia. We believe, therefore, that sputum gram staining is indispensable as a diagnostic tool CAP.

  4. Improved method for combination of immunocytochemistry and Nissl staining.

    PubMed

    Kádár, Andrea; Wittmann, Gábor; Liposits, Zsolt; Fekete, Csaba

    2009-10-30

    Nissl staining is a widely used method to study morphology and pathology of neural tissue. After standard immunocytochemistry, the Nissl staining labels only the nucleus of neurons and the characteristic staining of the neuronal perikarya is absent or very weak. We hypothesized that the RNA degradation during the immunocytochemical treatment results in the loss of cytoplasmic staining with Nissl-dyes. To test this hypothesis, we used RNAse-free conditions for all steps of immunostaining. To further prevent the RNA-degradation by RNAse contaminations, the RNAse inhibitor heparin was added to all antibody-containing solutions. The efficiency of Nissl staining after standard and RNAse-free double-labeling immunocytochemistry was compared using antibodies against c-Fos and neuropeptide Y (NPY) on tissues of rats refed after 3 days of fasting. After standard immunocytochemistry, the Nissl-staining labeled the nuclei of neurons and only very faintly the cytoplasm of these cells. The RNAse-free treatment did not alter the distribution of immunoreaction signal, but preserved the staining of neuronal perikarya by the Nissl-dyes. In conclusion, the RNAse-free conditions during immunocytochemistry allow the labeling of neuronal perikarya by Nissl-dyes. The described method facilitates the mapping of immunocytochemical signals and makes possible the light microscopic examination of the innervation of neurons identified by their nuclear protein content.

  5. Counterion dye staining of proteins in one- and two-dimensional sodium dodecyl sulfate-polyacrylamide gel electrophoresis and tryptic gel digestion of stained protein for mass spectrometry.

    PubMed

    Cong, Wei-Tao; Wang, Xu; Hwang, Sun-Young; Jin, Li-Tai; Choi, Jung-Kap

    2012-01-01

    A fast and matrix-assisted laser desorption/ionization mass spectrometry compatible protein staining method in one- and two-dimensional sodium dodecyl sulfate-polyacrylamide gel electrophoresis is described. It is based on the counterion dye staining method that employs oppositely charged two dyes, zincon and ethyl violet, to form an ion-pair complex. The protocol, including fixing, staining, and quick washing steps, can be completed in 1-1.5 h, depending upon gel thickness. It has the sensitivity comparable to the colloidal Coomassie Brilliant Blue G stain using phosphoric acid as a component of staining solution (4-8 ng). The counterion dye stain does not induce protein modifications that complicate interpretation of peptide mapping data from mass spectrometry. Considering the speed, sensitivity, and compatibility with mass spectrometry, the counterion dye stain may be more practical than any other dye-based protein stains for routine proteomic researches.

  6. Techniques for controlling variability in gram staining of obligate anaerobes.

    PubMed Central

    Johnson, M J; Thatcher, E; Cox, M E

    1995-01-01

    Identification of anaerobes recovered from clinical samples is complicated by the fact that certain gram-positive anaerobes routinely stain gram negative; Peptostreptococcus asaccharolyticus, Eubacterium plautii, Clostridium ramosum, Clostridium symbiosum, and Clostridium clostridiiforme are among the nonconformists with regard to conventional Gram-staining procedures. Accurate Gram staining of American Type Culture Collection strains of these anaerobic bacteria is possible by implementing fixing and staining techniques within a gloveless anaerobic chamber. Under anaerobic conditions, gram-positive staining occurred in all test organisms with "quick" fixing techniques with both absolute methanol and formalin. The results support the hypothesis that, when anaerobic bacteria are exposed to oxygen, a breakdown of the physical integrity of the cell wall occurs, introducing Gram stain variability in gram-positive anaerobes. PMID:7538512

  7. Stained-Glass Pastels

    ERIC Educational Resources Information Center

    Laird, Shirley

    2009-01-01

    The author has always liked the look of stained-glass windows. Usually the designs are simplified and the shapes are easier for younger students to draw. This technique seemed to be the perfect place for her fifth-graders to try their hand at color mixing. The smaller spaces and simple shapes were just what she needed for this group. Her students…

  8. Facile method to stain the bacterial cell surface for super-resolution fluorescence microscopy†

    PubMed Central

    Gunsolus, Ian L.; Hu, Dehong; Mihai, Cosmin; Lohse, Samuel E.; Lee, Chang-soo; Torelli, Marco D.; Hamers, Robert J.; Murhpy, Catherine J.; Orr, Galya

    2015-01-01

    A method to fluorescently stain the surfaces of both Gram-negative and Gram-positive bacterial cells compatible with super-resolution fluorescence microscopy is presented. This method utilizes a commercially-available fluorescent probe to label primary amines at the surface of the cell. We demonstrate eficient staining of two bacterial strains, the Gram-negative Shewanella oneidensis MR-1 and the Gram-positive Bacillus subtilis 168. Using structured illumination microscopy and stochastic optical reconstruction microscopy, which require high quantum yield or specialized dyes, we show that this staining method may be used to resolve the bacterial cell surface with sub-diffraction-limited resolution. We further use this method to identify localization patterns of nanomaterials, specifically cadmium selenide quantum dots, following interaction with bacterial cells. PMID:24816810

  9. Facile method to stain the bacterial cell surface for super-resolution fluorescence microscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gunsolus, Ian L.; Hu, Dehong; Mihai, Cosmin

    A method to fluorescently stain the surfaces of both Gram-negative and Gram-positive bacterial cells compatible with super-resolution fluorescence microscopy is presented. This method utilizes a commercially-available fluorescent probe to label primary amines at the surface of the cell. We demonstrate efficient staining of two bacterial strains, the Gram-negative Shewanella oneidensis MR-1 and the Gram-positive Bacillus subtilis 168. Using structured illumination microscopy and stochastic optical reconstruction microscopy, which require high quantum yield or specialized dyes, we show that this staining method may be used to resolve the bacterial cell surface with sub-diffraction-limited resolution. We further use this method to identify localizationmore » patterns of nanomaterials, specifically cadmium selenide quantum dots, following interaction with bacterial cells.« less

  10. An in vitro screening assay for dental stain cleaning.

    PubMed

    Wang, Changxiang; Lucas, Robert; Smith, Anthony J; Cooper, Paul R

    2017-01-09

    The present study aimed to develop an in vitro model for stain removal from natural enamel for the assessment and comparison of oral hygiene products. Bovine teeth (n = 8 per group) were ground/polished to provide flat enamel specimens and ferric-tannate deposits were precipitated onto the enamel surfaces. The ferric-tannate stained enamel specimens were brushed using an in vitro tooth-brushing simulator with slurries containing commercially available toothpaste products, dental abrasive particles, and sodium tripolyphosphate (STP) solutions of different concentrations. The colour of the enamel surfaces was measured using a spectrophotometer before and after stain application as well as after the brushing treatments. Differences in stain removal efficacy were found between the toothpastes categorised as whitening and non-whitening comprising of different types of dental abrasives (hydrated silica and alumina). A mean value of 27% for stain removal was detected for the three non-whitening toothpastes and 59% of stain removal was detected for the three whitening toothpastes after 1000 strokes. Compared with the slurry with Zeodent 113 abrasive alone, the addition of STP provided better performance for stain removal under the same brushing conditions (mean value of 62% for Zeodent 113 abrasive alone and 72% with the addition of 5% (w/w) STP after 1000 strokes). No difference was evident between the STP concentration of 5% (w/w) and 10% (w/w). The ferric-tannate/bovine enamel model reported here provides good stain retention, is rapidly and easily prepared, and is shown to be progressively and reproducibly sensitive to toothbrushing using different toothpastes and surfactant/chelating agent solutions. Importantly, it provides good discrimination between various oral hygiene products. The stain removal assay reported here has considerable potential to enable comparative assessments of different toothpaste types in terms of their cleaning capabilities.

  11. Case of Mycobacterium tuberculosis meningitis: Gram staining as a useful initial diagnostic clue for tuberculous meningitis.

    PubMed

    Kawakami, Sayoko; Kawamura, Yasuyosi; Nishiyama, Kyouhei; Hatanaka, Hiroki; Fujisaki, Ryuichi; Ono, Yasuo; Miyazawa, Yukihisa; Nishiya, Hajime

    2012-12-01

    A 32-year-old man was admitted to our hospital because of fever, headache, and loss of consciousness. Four days before admission, he had had difficulty speaking. On the day of admission, his colleague had found him to be unconscious and lying on his back. He was admitted to our hospital. The temperature at the eardrum was 35.2°C. Neurologic evaluation was negative. Computed tomography (CT) scan of the brain showed slight ventricular enlargement bilaterally. An X-ray film of the chest showed no abnormality. On the second hospital day, neck stiffness was noted. The cerebrospinal fluid (CSF) contained 870 white cells/μl, most of which were neutrophils; the glucose level in the CSF was 10 mg/dl, and the protein level was 140 mg/dl. Stained smears of the CSF, including Gram staining and India-ink preparations, disclosed no microorganisms. Capsular antigen tests for several bacteria were negative. Antimicrobial agents were started. However, by changing the microscope focus slightly while viewing Gram stains of the CSF, we could see brightened and Gram-positive bacilli that had been phagocytosed by neutrophils. This finding suggested the presence of Mycobacterium tuberculosis. Ziehl-Neelsen staining of the CSF and gastric juice revealed anti-acid bacilli. Polymerase chain reaction for M. tuberculosis in the gastric juice was positive. This case showed that Gram staining could be useful as an initial adjunct for the diagnosis of tuberculous meningitis, particularly when the CSF shows predominantly neutrocytic pleocytosis, but no other evidence of bacterial meningitis.

  12. Analysis of human papilloma virus in oral squamous cell carcinoma using p16: An immunohistochemical study

    PubMed Central

    Patil, S.; Rao, R. S.; Amrutha, N.; Sanketh, D. S.

    2014-01-01

    Aims: The aim of this study is to evaluate the expression of human papilloma virus (HPV) in oral squamous cell carcinoma (OSCC) and to correlate the association of HPV in histological grades of OSCC using p16 (p16INK4a) immunohistochemistry (IHC). Subjects and Methods: This study consists of 30 histological diagnosed cases of OSCC (10-well-differentiated oral squamous cell carcinoma [WDOSCC], 10-moderately differentiated oral squamous cell carcinoma [MDOSCC] and 10-poorly differentiated oral squamous cell carcinoma [PDOSCC]). The sections were subjected to IHC procedure using p16. Two parameters in immunohistochemical p16 expression were evaluated by 3 observers based on the criteria by Galgano M. Tetal (2010) (a) percentage of p16 positive cases (b) pattern of p16 staining in various grades of OSCC. Statistical Analysis Used: Kappa test. Results: Totally, 30 samples of 0SCC, p16 positivity was noted in 26/30 (86.66%). Of 26 positive cases, p16 staining was positive in 7/10 (70%) of WDOSCC, 9/10 (90%) in MDOSCC and, 10/10 (100%) PDOSCC. Incidentally, we also found single dispersed cell staining in WDOSCC, patchy staining in MDOSCC and more diffuse staining pattern predominant in PDOSCC. Conclusions: Our study revealed an association between HPV and OSCC. Diffuse staining pattern was noted in PDOSCC, which in turn depicts the increase viral overload, which might have an influence on its aggressive behavior. PMID:24818098

  13. Immunohistochemical expression of Ets-related gene-transcriptional factor in adenocarcinoma prostate and its correlation with Gleason score.

    PubMed

    Mannan, Rahul; Bhasin, Tejinder Singh; Manjari, Mridu; Singh, Gagandeep; Bhatia, Puneet Kaur; Sharma, Sonam

    2016-01-01

    Prostate carcinoma is the second leading cause of cancer-related deaths in males worldwide. The burden is expected to grow 1.7 million new cases and 499,000 new deaths by 2030. In developing countries such as India, prostate carcinoma will show an increase by 140% in the next few years. Although the diagnosis of prostate carcinoma can usually be made on histological features, now a days many immunohistochemical (IHC) markers are used to distinguish it from benign mimickers as well as in predicting prognosis and treatment. Out of these markers, Ets-related gene (ERG product) is a proto-oncogene which participates in chromosomal translocations and is frequently over expressed in prostate carcinoma which harbors ERG-transmembrane protease, serine 2 fusion. Fifty cases of carcinoma prostate diagnosed in needle biopsies and prostatic chips, in the Department of Pathology of a tertiary care teaching hospital in Punjab, India, were included in the present study. The slides were observed under the light microscope, and Gleason scoring was done using the 2005 International Society of Urological Pathology modified Gleason system. IHC study for ERG expression was done on all the cases, for which anti-ERG monoclonal rabbit clone antibody EP111 (Dako, Denmark) was used. Lymphocytes and endothelial cells were taken as in built positive controls for staining. The intensity of ERG positivity was scored as no staining (0), weak staining (+1), moderate staining (+2) and intense staining (+3). The H score was then calculated by multiplying the intensity of the stain with the percentage (0-100) of the cells showing that staining intensity. The H-score has a range of 0-300. The relationship between IHC expression and clinico-pathological parameters was compared and analyzed using Chi-square test. P < 0.05 was considered statistically significant. Majority of patients included in the study were in the age group of 61-80 (84% of the total). When ERG expression was studied with age

  14. Detection of Wolbachia endobacteria in Culex quinquefasciatus by Gimenez staining and confirmation by PCR.

    PubMed

    Muniaraj, M; Paramasivan, R; Sunish, I P; Arunachalam, N; Mariappan, T; Jerald Leo, S Victor; Dhananjeyan, K J

    2012-12-01

    Wolbachia are common intracellular bacteria that are found in arthropods and nematodes. These endosymbionts are transmitted vertically through host eggs and alter host biology in diverse ways, including the induction of reproductive manipulations, such as feminization, parthenogenesis, male killing and sperm-egg incompatibility. Since they can also move horizontally across species boundaries, Wolbachia is gaining importance in recent days as it could be used as a biological control agent to control vector mosquitoes or for paratransgenic approaches. However, the study of Wolbachia requires sophisticated techniques such as PCR and cell culture facilities which cannot be affordable for many laboratories where the diseases transmitted by arthropod vectors are common. Hence, it would be beneficial to develop a simple method to detect the presence of Wolbachia in arthropods. In this study, we described a method of staining Wolbachia endobacteria, present in the reproductive tissues of mosquitoes. The reliability of this method was compared with Gram staining and PCR based detection. The microscopic observation of the Gimenez stained smear prepared from the teased ovary of wild caught and Wolbachia (+) Cx. quinquefasciatus revealed the presence of pink coloured pleomorphic cells of Wolbachia ranging from cocci, comma shaped cells to bacillus and chain forms. The ovaries of Wolbachia (-) cured mosquito did not show any cell. Although Gram's staining is a reliable differential staining for the other bacteria, the bacterial cells in the smears from the ovaries of wild caught mosquitoes did not take the stain properly and the cells were not clearly visible. The PCR amplified product from the pooled remains of wild caught and Wolbachia (+) Cx. quinquefasciatus showed clear banding, whereas, no banding was observed for the negative control (distilled water) and Wolbachia (-) Cx. quinquefasciatus. The Gimenez staining technique applied, could be used to detect the members of

  15. Multimodal detection of GM2 and GM3 lipid species in the brain of mucopolysaccharidosis type II mouse by serial imaging mass spectrometry and immunohistochemistry.

    PubMed

    Dufresne, Martin; Guneysu, Daniel; Patterson, Nathan Heath; Marcinkiewicz, Mieczyslaw Martin; Regina, Anthony; Demeule, Michel; Chaurand, Pierre

    2017-02-01

    Mucopolysaccharidosis type II (Hunter's disease) mouse model (IdS-KO) was investigated by both imaging mass spectrometry (IMS) and immunohistochemistry (IHC) performed on the same tissue sections. For this purpose, IdS-KO mice brain sections were coated with sublimated 1,5-diaminonaphtalene and analyzed by high spatial resolution IMS (5 μm) and anti-GM3 IHC on the same tissue sections to characterize the ganglioside monosialated ganglioside (GM) deposits found in Hunter's disease. IMS analysis have found that two species of GM3 and GM2 that are only different due to the length of their fatty acid residue (stearic or arachidic residue) were overexpressed in the IdS-KO mice compared to a control mouse. GM3 and GM2 were characterized by on-tissue exact mass and MS/MS compared to a GM3 standard. Realignment of both IMS and IHC data sets further confirmed the observed regioselective signal previously detected by providing direct correlation of the IMS image for the two GM3 overly expressed MS signals with the anti-GM3 IHC image. Furthermore, these regioselective GM MS signals were also found to have highly heterogeneous distributions within the GM3-IHC staining. Some deposits showed high content in GM3 and GM2 stearic species (r = 0.74) and others had more abundant GM3 and GM2 arachidic species (r = 0.76). Same-section analysis of Hunter's disease mouse model by both high spatial resolution IMS and IHC provides a more in-depth analysis of the composition of the GM aggregates while providing spatial distribution of the observed molecular species. Graphical Abstract Ganglioside imaging mass spectrometry followed by immunohistochemistry performed on the same tissue section.

  16. Port wine stain on a child's face (image)

    MedlinePlus

    Port wine stains are always present at birth. In an infant, they are flat, pink, vascular lesions. Common locations ... may be present anywhere on the body. Port wine stains may appear in association with other syndromes.

  17. Taste in Art-Exposure to Histological Stains Shapes Abstract Art Preferences.

    PubMed

    Böthig, Antonia M; Hayn-Leichsenring, Gregor U

    2017-01-01

    Exposure to art increases the appreciation of artworks. Here, we showed that this effect is domain independent. After viewing images of histological stains in a lecture, ratings increased for restricted subsets of abstract art images. In contrast, a lecture on art history generally enhanced ratings for all art images presented, while a lecture on town history without any visual stimuli did not increase the ratings. Therefore, we found a domain-independent exposure effect of images of histological stains to particular abstract paintings. This finding suggests that the 'taste' for abstract art is altered by visual impressions that are presented outside of an artistic context.

  18. Different cytokeratin and neuronal cell adhesion molecule staining patterns in focal nodular hyperplasia and hepatic adenoma and their significance

    PubMed Central

    Iyer, Anita; Robert, Marie E.; Bifulco, Carlo B.; Salem, Ronald R.; Jain, Dhanpat

    2013-01-01

    Summary Differentiating focal nodular hyperplasia from hepatic adenoma can be challenging. Cytokeratin 7, neuronal cell adhesion molecule, and cytokeratin 19 are differentially expressed in hepatocytes, biliary epithelium, and possibly hepatic progenitor/stem cells. CD34 is known to have altered expression patterns in the hepatic endothelium in conditions associated with abnormal perfusion and in hepatocellular carcinoma. The purpose of this study was to examine the expression pattern of these markers in focal nodular hyperplasia and hepatic adenoma and assess their diagnostic use. Ten resection specimens each of hepatic adenoma and focal nodular hyperplasia (including a case of telangiectatic focal nodular hyperplasia) were selected for the study. Immunohistochemical analysis was performed using antibodies against cytokeratin 7, cytokeratin 19, neuronal cell adhesion molecule, and CD34 on formalin-fixed, paraffin-embedded sections from each case. The staining patterns and intensity for each marker were analyzed. In hepatic adenoma, the cytokeratin 7 stain revealed strong positivity in hepatocytes in patches, with a gradual decrease in the staining intensity as the cells differentiated towards mature hepatocytes. Although bile ducts were typically absent in hepatic adenoma, occasional ductules could be identified with cytokeratin 7 stain. In focal nodular hyperplasia, cytokeratin 7 showed strong staining of the biliary epithelium within the fibrous septa and staining of the peripheral hepatocytes of most lobules that was focal and weaker than hepatic adenoma. Cytokeratin 19 and neuronal cell adhesion molecule showed patchy and moderate staining in the biliary epithelium of the ductules in focal nodular hyperplasia. While in the hepatic adenoma, cytokeratin 19 showed only rare positivity in occasional cells within ductules, and neuronal cell adhesion molecule marked occasional isolated cells in the lesion. CD34 showed staining of sinusoids in the inflow areas

  19. Differences in staining intensities affect reported occurrences and concentrations of Giardia spp. in surface drinking water sources.

    PubMed

    Alderisio, K A; Villegas, L F; Ware, M W; McDonald, L A; Xiao, L; Villegas, E N

    2017-12-01

    USEPA Method 1623, or its equivalent, is currently used to monitor for protozoan contamination of surface drinking water sources worldwide. At least three approved staining kits used for detecting Cryptosporidium and Giardia are commercially available. This study focuses on understanding the differences among staining kits used for Method 1623. Merifluor and EasyStain labelling kits were used to monitor Cryptosporidium oocyst and Giardia cyst densities in New York City's raw surface water sources. In the year following a change to the approved staining kits for use with Method 1623, an anomaly was noted in the occurrence of Giardia cysts in New York City's raw surface water. Specifically, Merifluor-stained samples had higher Giardia cyst densities as compared with those stained with EasyStain. Side by side comparison revealed significantly lower fluorescence intensities of Giardia muris as compared with Giardia duodenalis cysts when labelled with EasyStain. This study showed very poor fluorescence intensity signals by EasyStain on G. muris cysts resulting in lower cyst counts, while Merifluor, with its broader Giardia cyst staining specificity, resulted in higher cyst counts, when using Methods 1623. These results suggest that detected Giardia cyst concentrations are dependent on the staining kits used, which can result in a more or less conservative estimation of occurrences and densities of zoonotic Giardia cysts by detecting a broader range of Giardia species/Assemblages. Published 2017. This article is a U.S. Government work and is in the public domain in the USA.

  20. Inadvertent trypan blue posterior capsule staining during cataract surgery.

    PubMed

    Burkholder, Bryn M; Srikumaran, Divya; Nanji, Afshan; Lee, Bryan; Weinberg, Robert S

    2013-04-01

    To report 5 cases of inadvertent posterior capsule staining with trypan blue during phacoemulsification. Retrospective, observational case series. Five cases of posterior capsule staining with trypan blue were identified from cataract surgeries performed at an academic institution. All 5 eyes underwent phacoemulsification with use of iris retractors. The surgical videos from each case were reviewed to better understand the mechanisms and risk factors for posterior capsule staining with trypan blue and techniques to avoid this complication. No eyes had clinical evidence of zonular pathology during their preoperative examination. Only 1 patient reported a possible childhood history of trauma to both eyes. One eye had uveitis, requiring posterior synechialysis. All 5 cases involved the use of iris retractors. No other intraoperative complications occurred, and the intraocular lens was successfully placed in the capsular bag in all cases. All eyes had resolution of posterior capsule staining by postoperative day 8. Inadvertent posterior capsule staining with trypan blue can occur in eyes that appear structurally normal. The use of iris retractors may facilitate posterior capsule staining by allowing the posterior flow of trypan blue under the iris and through the zonules to the posterior capsule. Surgeons should consider techniques to minimize the risk of posterior capsule staining, particularly in cases involving the use of iris retractors. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. Improved method for combination of immunocytochemistry and Nissl staining

    PubMed Central

    Kádár, Andrea; Wittmann, Gábor; Liposits, Zsolt; Fekete, Csaba

    2009-01-01

    Nissl-staining is a widely used method to study morphology and pathology of neural tissue. After standard immunocytochemistry, the Nissl-staining labels only the nucleus of neurons and the characteristic staining of the neuronal perikarya is absent or very weak. We hypothesized that the RNA degradation during the immunocytochemical treatment results in the loss of cytoplasmic staining with Nissl-dyes. To test this hypothesis, we used RNAse-free conditions for all steps of immunostaining. To further prevent the RNA-degradation by RNAse contaminations, the RNAse inhibitor heparin was added to all antibody-containing solutions. The efficiency of Nissl-staining after standard and RNAse-free double-labeling immunocytochemistry was compared using antibodies against c-Fos and neuropeptide Y (NPY) on tissues of rats refed after three days of fasting. After standard immunocytochemistry, the Nissl-staining labeled the nuclei of neurons and only very faintly the cytoplasm of these cells. The RNAse-free treatment did not alter the distribution of immunoreaction signal, but preserved the staining of neuronal perikarya by the Nissl-dyes. In conclusion, the RNAse-free conditions during immunocytochemistry, allows the labeling of neuronal perikarya by Nissl-dyes. The described method facilitates the mapping of immunocytochemical signals and makes possible the light microscopic examination of the innervation of neurons identified by their nuclear protein content. PMID:19615409

  2. The use of immunohistochemistry for biomarker assessment--can it compete with other technologies?

    PubMed

    Dunstan, Robert W; Wharton, Keith A; Quigley, Catherine; Lowe, Amanda

    2011-10-01

    A morphology-based assay such as immunohistochemistry (IHC) should be a highly effective means to define the expression of a target molecule of interest, especially if the target is a protein. However, over the past decade, IHC as a platform for biomarkers has been challenged by more quantitative molecular assays with reference standards but that lack morphologic context. For IHC to be considered a "top-tier" biomarker assay, it must provide truly quantitative data on par with non-morphologic assays, which means it needs to be run with reference standards. However, creating such standards for IHC will require optimizing all aspects of tissue collection, fixation, section thickness, morphologic criteria for assessment, staining processes, digitization of images, and image analysis. This will also require anatomic pathology to evolve from a discipline that is descriptive to one that is quantitative. A major step in this transformation will be replacing traditional ocular microscopes with computer monitors and whole slide images, for without digitization, there can be no accurate quantitation; without quantitation, there can be no standardization; and without standardization, the value of morphology-based IHC assays will not be realized.

  3. Localization of Alpha-Keratin and Beta-Keratin (Corneous Beta Protein) in the Epithelium on the Ventral Surface of the Lingual Apex and Its Lingual Nail in the Domestic Goose (Anser Anser f. domestica) by Using Immunohistochemistry and Raman Microspectroscopy Analysis.

    PubMed

    Skieresz-Szewczyk, Kinga; Jackowiak, Hanna; Buchwald, Tomasz; Szybowicz, Mirosław

    2017-08-01

    The epithelium of the ventral surface of the apex of the tongue in most birds is specified by the presence of the special superficial layer called lingual nail. The aim of the present study is to determine the localization of the alpha-keratin and beta-keratin (corneous beta protein) in this special epithelium in the domestic goose by using immunohistochemistry staining and the Raman spectroscopy analysis. Due to lack of commercially available antibodies to detect beta-keratin (corneous beta protein), the Raman spectroscopy was used as a specific tool to detect and describe the secondary structure of proteins. The immunohistochemical (IHC) detections reveal the presence of alpha-keratin in all layers of the epithelium, but significant differences in the distribution of the alpha-keratin in the epithelial layers appear. The staining reaction is stronger from the basal layer to the upper zone of the intermediate layer. The unique result is weak staining for the alpha-keratin in the lingual nail. Applications of the Raman spectroscopy as a complementary method not only confirmed results of IHC staining for alpha-keratin, but showed that this technique could be used to demonstrate the presence of beta-keratin (corneous beta protein). Functionally, the localization of alpha-keratin in the epithelium of the ventral surface of the lingual apex provides a proper scaffold for epithelial cells and promotes structural integrity, whereas the presence of beta-keratin (corneous beta protein) in the lingual nail, described also as exoskeleton of the ventral surface of the apex, endures mechanical stress. Anat Rec, 300:1361-1368, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  4. Factors influencing extract of Hibiscus sabdariffa staining of rat testes.

    PubMed

    Bassey, R B; Bakare, A A; Peter, A I; Oremosu, A A; Osinubi, A A

    2012-08-01

    Some plant extracts can be used in biology and medicine to reveal or identify cellular components and tissues. We investigated the effects of time and concentration on staining of histological sections of rat testes by an acidified extract of Hibiscus sabdariffa. An ethanolic extract of H. sabdariffa was diluted using 1% acetic acid in 70% ethanol to stain histological sections of testes at concentrations of 0.2, 0.1 and 0.05 g/ml for 5, 10, 15, 30, 45 and 60 min. The sections of testes were stained deep red. The staining efficiency of H. sabdariffa was greater at a high concentration and required less time to achieve optimal staining. H. sabdariffa is a strongly basic dye that can be used for various diagnostic purposes. Staining time and concentration must be considered to achieve optimal results.

  5. Detergent-compatible proteases: microbial production, properties, and stain removal analysis.

    PubMed

    Niyonzima, Francois Niyongabo; More, Sunil

    2015-01-01

    Proteases are one of the most important commercial enzymes used in various industrial domains such as detergent and leather industries. The alkaline proteases as well as other detergent-compatible enzymes such as lipases and amylases serve now as the key components in detergent formulations. They break down various stains during fabric washing. The search for detergent-compatible proteases with better properties is a continuous exercise. The current trend is to use detergent-compatible proteases that are stable over a wide temperature range. Although the proteases showing stability at elevated pH have the capacity to be used in detergent formulations, their usage can be significant if they are also stable and compatible with detergent and detergent ingredients, and also able to remove protein stains. Despite the existence of some reviews on alkaline proteases, there is no specification for the use of alkaline proteases as detergent additives. The present review describes the detergent-compatible proteases tested as detergent additives. An overview was provided for screening, optimization, purification, and properties of detergent compatible proteases, with an emphasis on the stability and compatibility of the alkaline proteases with the detergent and detergent compounds, as well as stain removal examination methods.

  6. Intrapartum and perinatal results associated with different degrees of staining of meconium stained amniotic fluid.

    PubMed

    Rodríguez Fernández, Vanesa; Ramón Y Cajal, Carlos Nicolás López; Ortiz, Elena Marín; Naveira, Emilio Couceiro

    2018-05-01

    To determine the intrapartum and perinatal results associated with different degrees of staining of meconium stained amniotic fluid (MSAF). In a retrospective cohort study of all singleton deliveries over a period of one year (2015) in a tertiary hospital, we compared different degrees of MSAF (yellow, green and thick) to clear amniotic fluids, and analysed in each group maternal, intrapartum and neonatal variables as well as umbilical cord blood gas analysis. Of the 3590 deliveries included, 503 (14%) had MSAF. The incidence of MSAF rises with gestational age at delivery, reaching 20.7% in gestations above 41 weeks compared to 4.3% below 37 weeks. As the amniotic fluid staining progresses we found a higher proportion of intrapartum fevers (p < 0.001), pathological fetal heart rate patterns (p < 0.05), operative vaginal deliveries and cesarean sections (p < 0.001), as well as the need for advanced neonatal resuscitation (p < 0.001). There was also a correlation between MSAF and low Apgar scores at five minutes (p < 0.001) and fetal-neonatal mortality (p < 0.001) but there was not a higher proportion of neonatal intensive care admissions (p > 0.05). We have observed a similar distribution of umbilical artery pH ranges in all groups (p > 0.05). MSAF was associated with an increase in the rate of pathological fetal heart rate patterns, intrapartum fevers, operative vaginal and cesarean section deliveries, need for neonatal resuscitation, low Apgar scores and higher fetal-neonatal mortality. Moreover, we found that the risks increase as the staining and consistency of the amniotic fluid evolves so it should alert the obstetrician and paediatrician to the potential adverse outcomes. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Expression and distribution patterns of spermine, spermidine, and putrescine in rat hair follicle.

    PubMed

    Yamamoto, Yutaro; Makino, Takamitsu; Kudo, Hideo; Ihn, Hironobu; Murakami, Yasuko; Matsufuji, Senya; Fujiwara, Kunio; Shin, Masashi

    2018-02-01

    No expression and distribution patterns of polyamines (PAs), spermine, spermidine, and their precursor putrescine in mammalian hair follicle are available, although polyamines are known to correlate well with hair growth and epidermal tumor genesis. Immunohistochemistry (IHC) using our original two monoclonal antibodies (mAbs) ASPM-29 specific for spermine or spermidine, and APUT-32 specific for putrescine allowed us to detect immunoreactivity for polyamines in hair follicles from normal adult rats. A wide range of immunoreactivity for the total spermine and spermidine was observed in the compartments of hair follicle: The highest degree of immunoreactivity for polyamines was observed in the matrix, in the Huxley's layer, in the deeper Henle's layer, and in the cuticle of the inner root sheath/the hair cuticle, while moderate immunoreactivity existed in the lower-to-mid cortex and the companion layer, followed by lower immunoreactivity in the outer root sheath, including the bulge region and in the deeper medulla, in which the immunoreactivity was also evident in their nuclei. In addition, somewhat surprisingly, with IHC by APUT-32 mAb, we detected significant levels of putrescine in the compartments, in which the immunostaining pattern was the closely similar to that of the total spermine and spermidine. Thus, among these compartments, the cell types of the matrix, the Huxley's layer, the deeper Henle's layer, and the cuticle of the inner root sheath/the hair cuticle seem to have the biologically higher potential in compartments of anagen hair follicle, maybe suggesting that they are involved more critically in the biological event of hair growth. In addition, we noted sharp differences of immunostaining by IHCs between ASPM-29 mAb and APUT-32 mAb in the epidermis cells and fibroblast. ASPM-29 mAb resulted in strong staining in both the cell types, but APUT-32 mAb showed only very light staining in both types. Consequently, the use of the two IHCs could be

  8. The use of a differential fluorescent staining method to detect bacteriuria.

    PubMed

    Ciancaglini, Ettore; Fazii, Paolo; Sforza, Giuseppe Riario

    2004-01-01

    This report describes a differential staining method which distinguishes gram-positive from gram-negative bacteria in fluorescence. Gram-positive bacteria appear yellow and gram-negative bacteria appear green. The method is based on two fluorochromes, one acting in the wavelength of red, i.e. the acridine orange, and another acting in the wavelength of green, i.e. the fluorescein, which together form a red/ green system. In this report we compared the accuracy of the differential fluorescent staining method and the Gram stain in screening for bacteriuria, as detected by conventional cultures. A total of 1487 urine samples were tested. 289 cultures were positive. 237 specimens grew a single organism at 10(5) and 10(4) CFU/ml. 224 smears were detected by the differential fluorescent staining method and 162 were detected by Gram stain. 1198 samples failed to grow organisms at 10(5) and 10(4) CFU/ml. 107 smears were falsely positive by the fluorescent staining procedure and 289 were falsely positive by the Gram stain. On the basis of the culture results, the sensitivity of the differential fluorescent staining method was 94.5% and that of the Gram stain 68.3%. The specificity of the fluorescent staining procedure was 91.6% and that of the Gram stain 75.8%. The positive predictive value and the negative predictive value of the fluorescent staining method were 67.6% and 98.8%, respectively. Those of the Gram stain were 35.9% and 92.3%, respectively. A wide range of microbiological and chemical techniques are available to identify bacteria in urine. This fluorescent staining method represents a simple, rapid, reliable method with low-running costs. The main advantage of this technique is that it enables the microbiologist to exclude the presence of bacteria in the urine within a short time after specimen receipt and to eliminate a large number of specimens for culture with significant cost saving. Another advantage of the method is that it allows to distinguish gram

  9. Protein Stains to Detect Antigen on Membranes.

    PubMed

    Dsouza, Anil; Scofield, R Hal

    2015-01-01

    Western blotting (protein blotting/electroblotting) is the gold standard in the analysis of complex protein mixtures. Electroblotting drives protein molecules from a polyacrylamide (or less commonly, of an agarose) gel to the surface of a binding membrane, thereby facilitating an increased availability of the sites with affinity for both general and specific protein reagents. The analysis of these complex protein mixtures is achieved by the detection of specific protein bands on a membrane, which in turn is made possible by the visualization of protein bands either by chemical staining or by reaction with an antibody of a conjugated ligand. Chemical methods employ staining with organic dyes, metal chelates, autoradiography, fluorescent dyes, complexing with silver, or prelabeling with fluorophores. All of these methods have differing sensitivities and quantitative determinations vary significantly. This review will describe the various protein staining methods applied to membranes after western blotting. "Detection" precedes and is a prerequisite to obtaining qualitative and quantitative data on the proteins in a sample, as much as to comparing the protein composition of different samples. "Detection" is often synonymous to staining, i.e., the reversible or irreversible binding by the proteins of a colored organic or inorganic chemical.

  10. Protein stains to detect antigen on membranes.

    PubMed

    D'souza, Anil; Scofield, R Hal

    2009-01-01

    Western blotting (protein blotting/electroblotting) is the gold standard in the analysis of complex protein mixtures. Electroblotting drives protein molecules from a polyacrylamide (or less commonly, of an agarose) gel to the surface of a binding membrane, thereby facilitating an increased availability of the sites with affinity for both general and specific protein reagents. The analysis of these complex protein mixtures is achieved by the detection of specific protein bands on a membrane, which in turn is made possible by the visualization of protein bands either by chemical staining or by reaction with an antibody of a conjugated ligand. Chemical methods employ staining with organic dyes, metal chelates, autoradiography, fluorescent dyes, complexing with silver, or prelabeling with fluorophores. All of these methods have differing sensitivities and quantitative determinations vary significantly. This review will describe the various protein staining methods applied to membranes after electrophoresis. "Detection" precedes and is a prerequisite to obtaining qualitative and quantitative data on the proteins in a sample, as much as to comparing the protein composition of different samples. Detection is often synonymous to staining, i.e., the reversible or irreversible binding by the proteins of a colored organic or inorganic chemical.

  11. Detection of erythrocyte membrane proteins, sialoglycoproteins, and lipids in the same polyacrylamide gel using a double-staining technique.

    PubMed Central

    Dzandu, J K; Deh, M E; Barratt, D L; Wise, G E

    1984-01-01

    A silver/Coomassie brilliant blue R-250 staining technique that permits a color-coded differentiation of erythrocyte membrane proteins, sialoglycoproteins, and lipids in a single one-dimensional NaDodSO4/polyacrylamide gel has been described. Gels stained first with silver stain and then with Coomassie blue (CB) showed the characteristic blue staining of all conventional CB-sensitive membrane polypeptides, whereas periodic acid-Schiff reagent-sensitive sialoglycoproteins and lipids stained yellow. Several yellow Ag-stained bands corresponding to major and minor sialoglycoproteins were detected at Mr X 10(-3) of 88, 72, 65, 41, 35, 31, 28, 24, and 20. Neuraminidase treatment of intact erythrocytes caused shifts in the electrophoretic mobilities of several yellow-stained bands without affecting the CB-stained polypeptide pattern. These observations afforded evidence that the yellow-staining bands were sialoglycoproteins and lipids. The double-staining technique was used in a topological analysis of the membrane surface of the erythrocyte using protease digestion and selective solubilization. Trypsin cleaved the yellow bands at Mr 88,000 and 41,000. Membrane-associated cleavage products were noted at Mr 58,000 and 38,000. Pronase treatment of intact cells gave membrane-associated cleavage products at Mr 38,000 (yellow) and two CB-stained bands at Mr 58,000 and 60,000. These results suggested that the double-staining technique may be applicable in compositional and topological analyses of other biological membranes. Images PMID:6200882

  12. Type 1 IGF Receptor Localization in Paediatric Gliomas: Significant Association with WHO Grading and Clinical Outcome.

    PubMed

    Clément, Florencia; Martin, Ayelen; Venara, Marcela; de Luján Calcagno, Maria; Mathó, Cecilia; Maglio, Silvana; Lombardi, Mercedes García; Bergadá, Ignacio; Pennisi, Patricia A

    2018-06-01

    Nuclear localization of insulin-like growth factor receptor type 1 (IGF-1R) has been described as adverse prognostic factor in some cancers. We studied the expression and localization of IGF-1R in paediatric patients with gliomas, as well as its association with World Health Organization (WHO) grading and survival. We conducted a single cohort, prospective study of paediatric patients with gliomas. Samples were taken at the time of the initial surgery; IGF-1R expression and localization were characterized by immunohistochemistry (IHC), subcellular fractionation and western blotting. Tumours (47/53) showed positive staining for IGF-1R by IHC. IGF-1R nuclear labelling was observed in 10/47 cases. IGF-1R staining was mostly non-nuclear in low-grade tumours, while IGF-1R nuclear labelling was predominant in high-grade gliomas (p = 0.0001). Survival was significantly longer in patients with gliomas having non-nuclear IGF-1R localization than in patients with nuclear IGF-1R tumours (p = 0.016). In gliomas, IGF-1R nuclear localization was significantly associated with both high-grade tumours and increased risk of death. Based on a prospective design, we provide evidence of a potential usefulness of intracellular localization of IGF-1R as prognostic factor in paediatric patients with gliomas.

  13. STUDIES ON FLUORESCENT ANTIBODY STAINING

    PubMed Central

    Goldstein, Gerald; Slizys, Irene S.; Chase, Merrill W.

    1961-01-01

    1. A study has been made of the non-specific fluorescent staining of splenic imprints treated with fluorescent sheep antibody globulins. 2. In tissue imprints made with the spleens of antigen-stimulated animals, no morphological distinction was evident between areas showing non-specific fluorescence and specific fluorescence. 3. Elimination of non-specific fluorescence was not achieved by any one, or any combination of the following: (a) conjugating only gamma globulins with fluorescein isothiocyanate; (b) removal of dialyzable fluorescent products on sephadex, followed by concentration through the use of pressure dialysis; (c) use of crystalline preparations of fluorescein isothiocyanate. 4. Individual preparations of fluorescent antibodies were separated by gradient elution chromatography on diethylaminoethyl (DEAE) cellulose into fractions possessing different numbers of fluorescein radicals per molecule of globulin. 5. The coupling ratio of 50 mg fluorescein isothiocyanate (FITC) per gm of protein, as commonly advocated, can not be recommended for the precise localization of antibody globulin in tissues owing to the capacity of the coupled products to give non-specific fluorescent staining. When crystalline preparations of FITC are used instead of the amorphous product at 50 mg/gm protein, far too high non-specific fluorescence results. 6. A fraction with bright specific fluorescence and no or negligible nonspecific fluorescence was obtained from each fluorescent antibody that was prepared by using 6 to 8 mg of crystalline fluorescein isothiocyanate per gm of globulin and was then subjected to DEAE-cellulose chromatography and gradient elution to eliminate the most highly coupled molecules. PMID:13706641

  14. Comparative study of IDH1 mutations in gliomas by immunohistochemistry and DNA sequencing

    PubMed Central

    Agarwal, Shipra; Sharma, Mehar Chand; Jha, Prerana; Pathak, Pankaj; Suri, Vaishali; Sarkar, Chitra; Chosdol, Kunzang; Suri, Ashish; Kale, Shashank Sharad; Mahapatra, Ashok Kumar; Jha, Pankaj

    2013-01-01

    Background Mutations involving isocitrate dehydrogenase 1 (IDH 1) occur in a high proportion of diffuse gliomas, with implications on diagnosis and prognosis. About 90% involve exon 4 at codon 132, replacing amino acid arginine with histidine (R132H). Rarer ones include R132C, R132S, R132G, R132L, R132V, and R132P. Most authors have used DNA-based methods to assess IDH1 status. Preliminary studies comparing imunohistochemistry (IHC) with IDH1-R132H mutation-specific antibodies have shown concordance with DNA sequencing and no cross-reactivity with wild-type IDH1 or other mutant proteins. The present study compares results of IHC with DNA sequencing in diffuse gliomas. Materials and methods Fifty diffuse gliomas with frozen tissue samples for DNA sequencing and adequate tissue in paraffin blocks for IHC using IDH1-R132H specific antibody were assessed for IDH1 mutations. Results Concordance of findings between IHC and DNA sequencing was noted in 88% (44/50) cases. All 6 cases with discrepancy were immunopositive with DIA-H09 antibody. While in 3 of these 6 cases, DNA sequencing failed to reveal any mutations, R132L (arginine replaced by leucine) mutation was found in the rest 3 cases. Interestingly, of the immunopositive cases, 46.6% (14/30) showed immunostaining in only a fraction of tumor cells. Conclusions IHC is an easy and quick method of detecting IDH1-R132H mutations, but there may be some discrepancies between IHC and DNA sequencing. Although there were no false-negative cases, cross-reactivity with IDH1-R132L was seen in 3, a finding not reported thus far. Because of more universal availability of IHC over genetic testing, cross-reactivity and staining heterogeneity may have bearing over its use in detecting IDH1-R132H mutation in gliomas. PMID:23486690

  15. Detection Of Concrete Deterioration By Staining

    DOEpatents

    Guthrie, Jr., George D.; Carey, J. William

    1999-09-21

    A method using concentrated aqueous solutions of sodium cobaltinitrite and a rhodamine dye is described which can be used to identify concrete that contains gels formed by the alkali-silica reaction (ASR), and to identify degraded concrete which results in a porous or semi-permeable paste due to carbonation or leaching. These solutions present little health or environmental risk, are readily applied, and rapidly discriminate between two chemically distinct gels; K-rich, Na--K--Ca--Si gels are identified by yellow staining, and alkali-poor, Ca--Si gels are identified by pink staining.

  16. Single step modified ink staining for Tzanck test: quick detection of herpetic giant cells in Tzanck smear.

    PubMed

    Mizutani, Hitoshi; Akeda, Tomoko; Yamanaka, Kei-Ichi; Isoda, Kenichi; Gabazza, Esteban C

    2012-02-01

    Tzanck test has been recently re-evaluated as a method for the diagnosis of herpes virus infection. Giemsa staining for the Tzanck test is time-consuming and laborious. There is a need to develop simple and quick staining methods for bedside diagnosis of this disease. We report a single step and quick method for staining herpes giant cells in Tzanck smears using routinely available inks and physiological saline. A keratinocyte cell line (HaCaT) was cultured on a slide glass and stained with various commercially available blue, blue-black and black inks serially diluted with physiological saline. Clinical smear samples from herpes lesions were also stained with these solutions without specific pretreatment. The nuclei of HaCaT were clearly stained showing high contrast with the cytoplasm using 5% Parker-Quink blue-black ink saline solution. Concentration of ink solution higher or lower than 5% resulted in less contrast. Blue or black inks or other manufacturers' inks can also be used, but staining of the cultured keratinocytes was less clear. Smear of clinical samples from herpes lesions were also stained with 5% ink solution. The nuclei of the multinucleated giant cells were clearly stained, and the sample could be immediately used for microscopic examination. One step staining of Tzanck smear using this diluted ink solution is an inexpensive and a convenient bedside diagnostic tool for the dermatologist. © 2011 Japanese Dermatological Association.

  17. News from the Biological Stain Commission No. 11.

    PubMed

    Lyon, H O; Horobin, R W

    2012-01-01

    The 11th issue of News from the Biological Stain Commission (BSC) provides our first impressions of the REACH and ECHA programs. We intend to give a more thorough account of what these important programs actually mean in later editions of News from the Biological Stain Commission. Under the heading of Regulatory Affairs, the Biological Stain Commission's International Affairs Committee presents information from the opening session of the meeting of the International Standards Organization ISO/TC 212 Clinical laboratory testing and in vitro diagnostic test systems held on 2-4 June 2010 in Seoul, Republic of Korea.

  18. Methods of biological dosimetry employing chromosome-specific staining

    DOEpatents

    Gray, Joe W.; Pinkel, Daniel

    2000-01-01

    Methods and compositions for staining based upon nucleic acid sequence that employ nucleic acid probes are provided. Said methods produce staining patterns that can be tailored for specific cytogenetic analyses. Said probes are appropriate for in situ hybridization and stain both interphase and metaphase chromosomal material with reliable signals. The nucleic acid probes are typically of a complexity greater than 50 kb, the complexity depending upon the cytogenetic application. Methods are provided to disable the hybridization capacity of shared, high copy repetitive sequences and/or remove such sequences to provide for useful contrast. Still further methods are provided to produce chromosome-specific staining reagents which are made specific to the targeted chromosomal material, which can be one or more whole chromosomes, one or more regions on one or more chromosomes, subsets of chromosomes and/or the entire genome. Probes and test kits are provided for use in tumor cytogenetics, in the detection of disease related loci, in analysis of structural abnormalities, such as translocations, and for biological dosimetry. Further, methods and prenatal test kits are provided to stain targeted chromosomal material of fetal cells, including fetal cells obtained from maternal blood. Still further, the invention provides for automated means to detect and analyse chromosomal abnormalities.

  19. A useful single-solution polychrome stain for plant material...Brook Cyte-Chrome I.

    Treesearch

    Stanley L Krugman; Julia F. Littlefield

    1968-01-01

    Fresh and chemically fixed sectioned plant material can be quickly stained by applying a Brook Cyte Chrome I polychrome stain. Staining time averaged only about 10 minutes. And exact timing of staining and de-staining is not as critical as with most of the commonly used stains. The overall quality is comparable to that of the traditional stains.

  20. Nucleic acid stains as indicators of Giardia muris viability following cyst inactivation.

    PubMed

    Taghi-Kilani, R; Gyürék, L L; Millard, P J; Finch, G R; Belosevic, M

    1996-06-01

    A reliable viability assay for Giardia is required for the development of disinfection process design criteria and pathogen monitoring by water treatment utilities. Surveys of single-staining nucleic acid dyes (stain dead parasites only), and double-staining vital dye kits from Molecular Probes (stain live and dead parasites) were conducted to assess the viability of untreated, heat-killed, and chemically inactivated Giardia muris cysts. Nucleic acid staining results were compared to those of in vitro excystation and animal infectivity. Nucleic acid stain, designated as SYTO-9, was considered the best among the single-staining dyes for its ability to stain dead cysts brightly and its relatively slow decay rate of visible light emission following DNA binding. SYTO-9 staining was correlated to animal infectivity. A Live/Dead BacLight was found to be the better of 2 double-staining viability kits tested. Logarithmic survival ratios based on SYTO-9 and Live/Dead BacLight were compared to excystation and infectivity results for G. muris cysts exposed to ozone or free chlorine. The results indicate that SYTO-9 and Live/Dead BacLight staining is stable following treatment of cysts with chemical disinfectants.

  1. Nuclear staining with alum hematoxylin.

    PubMed

    Llewellyn, B D

    2009-08-01

    The hematoxylin and eosin stain is the most common method used in anatomic pathology, yet it is a method about which technologists ask numerous questions. Hematoxylin is a natural dye obtained from a tree originally found in Central America, and is easily converted into the dye hematein. This dye forms coordination compounds with mordant metals, such as aluminum, and the resulting lake attaches to cell nuclei. Regressive formulations contain a higher concentration of dye than progressive formulations and may also contain a lower concentration of mordant. The presence of an acid increases the life of the solution and in progressive solutions may also affect selectivity of staining. An appendix lists more than 60 hemalum formulations and the ratio of dye to mordant for each.

  2. Can Melan-A replace S-100 and HMB-45 in the evaluation of sentinel lymph nodes from patients with malignant melanoma?

    PubMed

    Kucher, Cynthia; Zhang, Paul J; Acs, Geza; Roberts, Shelley; Xu, Xiaowei

    2006-09-01

    The sentinel lymph node (SLN) biopsy has become an increasingly important procedure used in the primary staging of malignant melanoma. However, micrometastases in a lymph node can be easily missed on routine H&E-stained sections. Therefore, S-100 and HMB-45 IHC stains are standardly performed on grossly negative SLNs for detection of metastatic melanoma. Each of these IHC markers, however, is not ideal. The authors investigated whether the newer IHC marker Melan-A would improve the detection of metastatic melanoma in SLN biopsies. Forty lymph nodes previously diagnosed with metastatic melanoma were retrospectively evaluated for S-100, HMB-45, and Melan-A expression. In addition, 42 SLN biopsies for metastatic melanoma detection were prospectively collected and evaluated for S-100, HMB-45, and Melan-A expression. All lymph nodes with metastatic melanoma from the retrospective study demonstrated S-100 reactivity. Five of the lymph nodes with metastatic melanoma from the retrospective study failed to express either HMB-45 or Melan-A, all of which displayed a desmoplastic morphology. One of the metastases positive for S-100 and HMB-45 failed to show reactivity with Melan-A (3%). The prospective study found 10 lymph nodes from 42 cases to be positive for metastatic melanoma, which were positive for S-100 (100%). Nine of the involved lymph nodes were positive for HMB-45(90%), and nine were positive for Melan-A (90%). Melan-A, although very specific, cannot replace the use of S-100 and HMB-45 for the detection of metastatic melanoma in SLNs. It can, however, substitute for HMB-45 with equally good results.

  3. Expression of FAP, ADAM12, WISP1, and SOX11 is heterogeneous in aggressive fibromatosis and spatially relates to the histologic features of tumor activity.

    PubMed

    Misemer, Benjamin S; Skubitz, Amy P N; Carlos Manivel, J; Schmechel, Stephen C; Cheng, Edward Y; Henriksen, Jonathan C; Koopmeiners, Joseph S; Corless, Christopher L; Skubitz, Keith M

    2014-02-01

    Aggressive fibromatosis (AF) represents a group of tumors with a variable and unpredictable clinical course, characterized by a monoclonal proliferation of myofibroblastic cells. The optimal treatment for AF remains unclear. Identification and validation of genes whose expression patterns are associated with AF may elucidate biological mechanisms in AF, and aid treatment selection. This study was designed to examine the protein expression by immunohistochemistry (IHC) of four genes, ADAM12, FAP, SOX11, and WISP1, that were found in an earlier study to be uniquely overexpressed in AF compared with normal tissues. Digital image analysis was performed to evaluate inter- and intratumor heterogeneity, and correlate protein expression with histologic features, including a histopathologic assessment of tumor activity, defined by nuclear chromatin density ratio (CDR). AF tumors exhibited marked inter- and intratumor histologic heterogeneity. Pathologic assessment of tumor activity and digital assessment of average nuclear size and CDR were all significantly correlated. IHC revealed protein expression of all four genes. IHC staining for ADAM12, FAP, and WISP1 correlated with CDR and was higher, whereas SOX11 staining was lower in tumors with earlier recurrence following excision. All four proteins were expressed, and the regional variation in tumor activity within and among AF cases was demonstrated. A spatial correlation between protein expression and nuclear morphology was observed. IHC also correlated with the probability of recurrence following excision. These proteins may be involved in AF pathogenesis and the corresponding pathways could serve as potential targets of therapy. © 2013 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  4. Standardization of stain used for diagnosing erythrocytic inclusion body syndrome (EIBS)

    USGS Publications Warehouse

    1987-01-01

    Erythrocytic inclusion body syndrome (EIBS), a viral erythrocytic necrosis (VEN)-like disease, has been observed in several areas in the Northwest. This virus disease is clinically diagnosed by microscopic examination of blood smears for intracytoplasmic erythrocytic inclusion bodies. Fish biologists involved in EIBS diagnostic work have been using several types of hematological stains. It became apparent that standardization of the staining procedure was needed. Comparative tests were conducted on blood smears and kidney imprints with the following commonly used blood stains: (1) Leishman-Giesma, (2) Pinacyanol chloride, (3) Powell 's Giemsa, (4) Harleco's Giemsa, (5) Diff Quik differential stain, (6) Wright's.Pinacyanol chloride stain was found to be the most consistent. The following staining procedure is recommended.

  5. Sudan stain of fecal fat: new insight into an old test.

    PubMed

    Khouri, M R; Huang, G; Shiau, Y F

    1989-02-01

    The 72-h fecal fat determination is used as the gold standard to document the presence of steatorrhea. Although the Sudan stain for fecal fat is advocated as a sensitive screening test, a quantitative correlation between the 72-h fecal fat quantitation and the fecal Sudan stain is lacking. This study was designed to examine the staining properties of different classes of purified lipids in an experimentally defined artificial matrix, and to elucidate the reasons for the lack of quantitative correlation between these two tests. Our results indicate that the "neutral fat" stain without acidification or heating identifies triglyceride; and at an appropriate pH, the "neutral stain" also identifies fatty acid. The "split fat" stain with acidification and heating identifies both triglyceride and fatty acid. After acidification, fatty acid soaps are converted to the nonionized fatty acid. Thus, fatty acid soaps can be identified indirectly as fat droplets that are stained by the split fat stain. Although cholesterol is stained with Sudan stain after heating, upon cooling, cholesterol forms crystals of anhydrous cholesterol, making its staining pattern distinct. Neither the neutral fat nor the split fat stain can detect phospholipid or cholesteryl ester. The 72-h fecal fat determination is a measure of the total fatty acid content after a specimen is saponified. The resulting fatty acids are derived from a variety of endogenous and exogenous sources, including free fatty acids, soaps of fatty acids, triglycerides, cholesterol esters, and phospholipids. Therefore, the 72-h fecal fat quantitation does not differentiate between the primary sources of the measured fatty acid. It is concluded that the 72-h fecal fat determination is not specific for documenting triglyceride (fat) malabsorption. Until new methods are developed that specifically measure fecal triglyceride and fatty acid, the Sudan stain of fecal fat appears to be a more specific method for detecting the presence

  6. EFFECTS OF THE GRAM STAIN ON MICROSPHERES FROM THERMAL POLYAMINO ACIDS1

    PubMed Central

    Fox, Sidney W.; Yuyama, Shuhei

    1963-01-01

    Fox, Sidney W. (The Florida State University, Tallahassee) and Shuhei Yuyama. Effects of the Gram stain on microspheres from thermal polyamino acids. J. Bacteriol. 85:279–283. 1963.—Microspheres produced from acid proteinoid accept the Gram stain. The stain is negative, but microspheres produced from mixtures containing a sufficient proportion of lysine proteinoid stain positive. Microspheres produced from mixtures containing the appropriate proportions contain individuals which stain positive and others which stain negative. Images PMID:13959050

  7. Virgin coconut oil (VCO) by normalizing NLRP3 inflammasome showed potential neuroprotective effects in Amyloid-β induced toxicity and high-fat diet fed rat.

    PubMed

    Mirzaei, Fatemeh; Khazaei, Mozafar; Komaki, Alireza; Amiri, Iraj; Jalili, Cyrus

    2018-05-02

    Both dyslipidemia and Alzheimer disease (AD) are associated with aging. In this study, the effects of virgin coconut oil (VCO) on inflammasome and oxidative stress in Alzheimer's model (receiving Amyloid-β (Aβ)) and high-fat diet (HFD) model were determined. A total of 120 male Wistar rats, were divided into 12 groups (n = 10), including; healthy control, sham surgery, sham surgery receiving normal saline, HFD, HFD + 8% VCO, HFD + 10% VCO, Aβ received rats, Aβ + 8%VCO, Aβ + 10%VCO, HFD + Aβ, HFD + Aβ+8%VCO, and HFD + Aβ + 10%VCO. Following memory and learning tests, blood sample prepared from the heart and hippocampus of rats in each group was kept at -70 °C for genes expression, oxidative stress, and biochemical tests. Aβ and HFD significantly impaired memory and learning by activating of both NOD-like receptor family pyrin domain containing 3 (NLRP3) inflammasome and oxidative stress (p<0.05), while treatment with both 8 and 10% VCO normalized inflammasome genes expression and oxidative stress (p<0.05). The Congo Red, Cresyl Violet staining and immunohistochemistry (IHC) test revealed that VCO improved hippocampus histological changes, reduced Aβ plaques and phosphorylated Tau. High-fat diet has exacerbated the effects of Aβ, while VCO showed potential neuroprotective effect. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Clinical utility of an automated instrument for gram staining single slides.

    PubMed

    Baron, Ellen Jo; Mix, Samantha; Moradi, Wais

    2010-06-01

    Gram stains of 87 different clinical samples were prepared by the laboratory's conventional methods (automated or manual) and by a new single-slide-type automated staining instrument, GG&B AGS-1000. Gram stains from either heat- or methanol-fixed slides stained with the new instrument were easy to interpret, and results were essentially the same as those from the methanol-fixed slides prepared as a part of the routine workflow. This instrument is well suited to a rapid-response laboratory where Gram stain requests are commonly received on a stat basis.

  9. Crossover clinical investigation of a whitening chewing gum for inhibiting dental stain formation in conjunction with tooth brushing.

    PubMed

    Milleman, Jeffery L; Milleman, Kimberly R; Kleber, Carl J; Proskin, Howard M; Dodds, Michael; Kelley, Michael; Ramirez, Lilian

    2014-01-01

    The purpose of this clinical investigation was to evaluate the effectiveness of a marketed whitening chewing gum compared to a no-gum control in preventing the formation of extrinsic stains on the teeth of stain-forming subjects when chewed over a 12-week period of regular unsupervised use in conjunction with daily tooth brushing. This was a single-center, examiner-blind, randomized, 12-week crossover clinical trial. Stain-forming (after smoking or drinking coffee or tea) adults, starting with a stain-free baseline, either chewed the test gum (Orbit White) unsupervised four times per day, 15 minutes/chew, or used no gum along with daily brushing with a commercially available toothbrush and dentifrice for 12 weeks. At the crossover, all procedures were repeated with subjects assigned the opposite treatment. Extrinsic stain was measured at six and 12 weeks by both the Lobene Stain Index (LSI) and the Modified Lobene Stain Index (MLSI) using separate experienced examiners. After 12 weeks, LSI stain scores showed a significant 25% reduction (p = 0.0008) in new stain formation for subjects using the test chewing gum along with tooth brushing versus tooth brushing alone (no-gum control). The corresponding MLSI stain scores demonstrated a 36% reduction (p < 0.0001) in the formation of extrinsic stain on the teeth. The overall findings of this clinical study demonstrated that regular use of Orbit White chewing gum, soon after smoking or drinking coffee or tea, will supplement daily tooth brushing in preventing unsightly stains from forming on the anterior teeth compared to brushing alone.

  10. B Cell Lymphoma, Unclassifiable, Transformed from Follicular Lymphoma: A Rare Presentation with Review of the Literature

    PubMed Central

    Kanna, Anila; Agrawal, Swati; Jayant, Kumar; Kumar Pala, Varun; Altujjar, Mohammad; Hadid, Tarik; Khurram, Muhammad

    2015-01-01

    B cell lymphoma, unclassifiable, with features of diffuse large B cell lymphoma and classical Hodgkin's lymphoma (BCLu-DLBCL/CHL) is more commonly known as gray zone lymphoma. These cases more often present with mediastinal disease. In this report, we present a very rare case of BCLu-DLBCL/CHL without mediastinal involvement, transformed from follicular lymphoma (FL) to BCLu-DLBCL/CHL. This patient initially presented with a mass in the right neck; biopsy of the lymph node showed predominantly nodular, follicular pattern. Immunohistochemical (IHC) staining of tumor cells expressed positivity for mature B cell markers CD20, CD19, CD10, CD23, CD45, and CD38 but negative for CD5,11c. Hence, diagnosed with FL, he was given rituximab, cyclophosphamide, vincristine, and prednisone (RCVP) regimen, followed by maintenance rituximab. He showed good response. After 2 years, he presented again with a mass in the right side of the neck. Although the needle core biopsy of this mass was suggestive of B cell lymphoma, excisional biopsy showed morphological features of DLBCL as well as foci of histological pattern of CHL. IHC staining expressed positivity for CD20, CD79a, PAX5, and CD15 and CD30 consistent with DLBCL and CHL. He was diagnosed with BCLu-DLBCL/CHL. The patient received “ACVBP” (doxorubicin, cyclophosphamide, vindesine, bleomycin, and prednisone) followed by radiation. BCLu-DLBCL/CHL is clinically an aggressive tumor with poorer outcomes, but our case showed complete response to ACVBP regimen with tumor regression. PMID:26380128

  11. B Cell Lymphoma, Unclassifiable, Transformed from Follicular Lymphoma: A Rare Presentation with Review of the Literature.

    PubMed

    Kanna, Anila; Agrawal, Swati; Jayant, Kumar; Kumar Pala, Varun; Altujjar, Mohammad; Hadid, Tarik; Khurram, Muhammad

    2015-01-01

    B cell lymphoma, unclassifiable, with features of diffuse large B cell lymphoma and classical Hodgkin's lymphoma (BCLu-DLBCL/CHL) is more commonly known as gray zone lymphoma. These cases more often present with mediastinal disease. In this report, we present a very rare case of BCLu-DLBCL/CHL without mediastinal involvement, transformed from follicular lymphoma (FL) to BCLu-DLBCL/CHL. This patient initially presented with a mass in the right neck; biopsy of the lymph node showed predominantly nodular, follicular pattern. Immunohistochemical (IHC) staining of tumor cells expressed positivity for mature B cell markers CD20, CD19, CD10, CD23, CD45, and CD38 but negative for CD5,11c. Hence, diagnosed with FL, he was given rituximab, cyclophosphamide, vincristine, and prednisone (RCVP) regimen, followed by maintenance rituximab. He showed good response. After 2 years, he presented again with a mass in the right side of the neck. Although the needle core biopsy of this mass was suggestive of B cell lymphoma, excisional biopsy showed morphological features of DLBCL as well as foci of histological pattern of CHL. IHC staining expressed positivity for CD20, CD79a, PAX5, and CD15 and CD30 consistent with DLBCL and CHL. He was diagnosed with BCLu-DLBCL/CHL. The patient received "ACVBP" (doxorubicin, cyclophosphamide, vindesine, bleomycin, and prednisone) followed by radiation. BCLu-DLBCL/CHL is clinically an aggressive tumor with poorer outcomes, but our case showed complete response to ACVBP regimen with tumor regression.

  12. YAP expression in normal and neoplastic breast tissue: an immunohistochemical study.

    PubMed

    Jaramillo-Rodríguez, Yolanda; Cerda-Flores, Ricardo M; Ruiz-Ramos, Ruben; López-Márquez, Francisco C; Calderón-Garcidueñas, Ana Laura

    2014-04-01

    Yes-associated protein (YAP) is a transcriptional factor involved in normal cell proliferation, apoptosis and carcinogenesis; however, its contribution to breast cancer (BC) is still controversial. We undertook this study to compare the expression of YAP by immunohistochemistry (IHC) in normal breast tissue of women without breast cancer (BC) (controls), non-neoplastic breast tissue in women with cancer (internal controls) and in four different subtypes of invasive ductal carcinoma. There were 17 controls and 105 tumor cases (53 luminal A, 15 luminal B, 20 overexpression of HER2 and 17 triple negative cases) studied by IHC. Statistical analysis included χ(2) for linear trend (Extended Mantel-Haenszel). There were 40% of internal controls that showed expression of YAP in myoepithelial cells, whereas in controls expression was 100%. In controls, 3/17 (17.6%) showed cytoplasmic staining in luminal cells. There was a significant difference in nuclear expression between the ductal BC subtypes. Luminal A had 4% of positive cases with <10% of cells affected in each case; in contrast, there were 17-20% of positive cases in the other groups with 50% or more of stained cells. YAP expression in stromal cells was not observed in controls or in triple-negative cases, and luminal B pattern had the highest YAP nuclear expression (20%). YAP showed decreased expression in tumor cells compared with normal breast tissue. These findings are consistent with a role of YAP as a suppressor gene in BC and show differences in YAP expression in different patterns of ductal BC. Copyright © 2014 IMSS. Published by Elsevier Inc. All rights reserved.

  13. Evaluation of efficacy of 1% Crystal Violet & Nuclear Fast Red stain compared to Haematoxyline & Eosin stain for assessing mitotic figures in oral premalignant and malignant lesions.

    PubMed

    Motiwale, Gauri; Jaiswal, Shradha; Vikey, Ashok; Motiwale, Tejas; Bagulkar, Bhupesh; Bhat, Atul; Kapoor, Prakhar

    2016-07-01

    Various chromosomal arrangements in cells undergoing division are referred to as Mitotic figure (MF). The abnormal excess of mitotic figures is commonly seen in oral epithelial dysplasia (ED) and oral squamous cell carcinoma (OSCC). In present study, we compared the number of mitotic figures in normal oral mucosa, epithelial dysplasia & OSCC sections with haematoxyline & eosine (H&E) and 1%Crystal Violet & Nuclear Fast Red (CV&NFR) stain, also the efficacy of the CV&NFR stain as compared to H & E stain. We investigated the correlation between the number of mitotic figures & grades of OSCC. Study sample comprised of two serial sections of archival blocks of normal oral mucosa & diagnosed cases of epithelial dysplasia & OSCC. One slide stained with H& E & the other one with 1% CV & NFR. Mitotic figures were counted with the grid eyepiece. There was significant increase in number of MFs in oral ED and OSCC in comparison with normal oral mucosa. There was a highly significant increase in number of MFs in CV&NFR stained tissue sections when compared with H & E stain. Metaphase is the most commonly observed phase of mitosis. In summary, our study proposes the use of Crystal violet & Nuclear fast red stain as a selective stain for better contrast & easy identification MFs. © 2016 Old City Publishing, Inc.

  14. Staining for factor VIII related antigen and Ulex europaeus agglutinin I (UEA-I) in 230 tumours. An assessment of their specificity for angiosarcoma and Kaposi's sarcoma.

    PubMed

    Leader, M; Collins, M; Patel, J; Henry, K

    1986-11-01

    In this study we examined the staining reactivity of commercially available antisera to factor VIII related antigen (F VIII RAg) and Ulex europaeus agglutinin I (UEA-I) on sections from 230 formalin fixed paraffin embedded tumours. These included 196 sarcomas, 20 carcinomas and 14 angiomas. All angiomas showed positive staining for F VIII RAg; all carcinomas showed negative staining; the vasoformative areas of all angiosarcomas stained positively but only four of six angiosarcomas showed positive staining of their solid areas; of seven Kaposi's sarcomas, all showed positive staining of vessels and six showed positive staining of the spindle cell component. In the remaining 181 non-vascular sarcomas there was a false positive result in four tumours (2.2%), three of which had a history of irradiation. Pre-radiotherapy biopsies of these three tumours stained negatively with anti-F VIII RAg. UEA-I was demonstrated in all the angiomas studied, in all angiosarcomas (including the solid components) and in well-formed vessels of all Kaposi's sarcomas, but only in the spindle cell component of 3/6. However, there was an unacceptably high rate of false positive staining amongst the carcinomas and non-vascular sarcomas. In conclusion, F VIII RAg is a specific but not a sensitive marker of angiosarcomas; UEA-I is a sensitive but not a specific marker of angiosarcomas.

  15. Staining of E-selectin ligands on paraffin-embedded sections of tumor tissue.

    PubMed

    Carrascal, Mylène A; Talina, Catarina; Borralho, Paula; Gonçalo Mineiro, A; Henriques, Ana Raquel; Pen, Cláudia; Martins, Manuela; Braga, Sofia; Sackstein, Robert; Videira, Paula A

    2018-05-02

    The E-selectin ligands expressed by cancer cells mediate adhesion of circulating cancer cells to endothelial cells, as well as within tissue microenvironments important for tumor progression and metastasis. The identification of E-selectin ligands within cancer tissue could yield new biomarkers for patient stratification and aid in identifying novel therapeutic targets. The determinants of selectin ligands consist of sialylated tetrasaccharides, the sialyl Lewis X and A (sLe X and sLe A ), displayed on protein or lipid scaffolds. Standardized procedures for immunohistochemistry make use of the antibodies against sLe X and/or sLe A . However, antibody binding does not define E-selectin binding activity. In this study, we developed an immunohistochemical staining technique, using E-selectin-human Ig Fc chimera (E-Ig) to characterize the expression and localization of E-selectin binding sites on paraffin-embedded sections of different cancer tissue. E-Ig successfully stained cancer cells with high specificity. The E-Ig staining show high reactivity scores in colon and lung adenocarcinoma and moderate reactivity in triple negative breast cancer. Compared with reactivity of antibody against sLe X/A , the E-Ig staining presented higher specificity to cancer tissue with better defined borders and less background. The E-Ig staining technique allows the qualitative and semi-quantitative analysis of E-selectin binding activity on cancer cells. The development of accurate techniques for detection of selectin ligands may contribute to better diagnostic and better understanding of the molecular basis of tumor progression and metastasis.

  16. Chromosome-specific staining to detect genetic rearrangements

    DOEpatents

    Gray, Joe W.; Pinkel, Daniel; Tkachuk, Douglas; Westbrook, Carol

    2013-04-09

    Methods and compositions for staining based upon nucleic acid sequence that employ nucleic acid probes are provided. Said methods produce staining patterns that can be tailored for specific cytogenetic analyzes. Said probes are appropriate for in situ hybridization and stain both interphase and metaphase chromosomal material with reliable signals. The nucleic acid probes are typically of a complexity greater than 50 kb, the complexity depending upon the cytogenetic application. Methods and reagents are provided for the detection of genetic rearrangements. Probes and test kits are provided for use in detecting genetic rearrangements, particularly for use in tumor cytogenetics, in the detection of disease related loci, specifically cancer, such as chronic myelogenous leukemia (CML) and for biological dosimetry. Methods and reagents are described for cytogenetic research, for the differentiation of cytogenetically similar but genetically different diseases, and for many prognostic and diagnostic applications.

  17. Diagnostic performance of dual-staining cytology for cervical cancer screening: A systematic literature review.

    PubMed

    Tjalma, Wiebren A A

    2017-03-01

    Cervical cancer screening saves lives. Secondary prevention in cervical cancer screening relies on the results of primary cytology and/or HPV testing. However, primary screening with cytology has a low sensitivity, and HPV screening has a low specificity. This means that either cancers are missed, or women are over-treated. To improve performance outcomes, the concept of dual-stain cytology (CINtec ® PLUS Cytology test) has been introduced. In this approach, additional staining with p16/Ki-67 is performed in cases where cytology results are abnormal (LSIL or ASCUS) and/or HPV-positive. Another way to describe this approach might be "diagnostic" cytology. In order to assess the value of this "diagnostic cytology", a systematic literature review was conducted of dual-stain cytology performance across multiple studies until May 2016. In a Belgian screening population (women age 25-65 years), dual-stain cytology was significantly more sensitive (66%) and slightly less specific (-1.0%) than cytology. In the population referred to colposcopy or with abnormal cytology (ASCUS, LSIL), dual-staining showed a significantly higher increase in specificity, and a slightly lower sensitivity than HPV testing. Specificity gains resulted in fewer false positives and an increase in the number of correct referrals to colposcopy. Dual-staining with p16/Ki-67 cytology is an attractive biomarker approach for triage in cervical cancer screening. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Color stability of resin used for caries infiltration after exposure to different staining solutions.

    PubMed

    Borges, Ab; Caneppele, Tmf; Luz, M; Pucci, Cr; Torres, Crg

    2014-01-01

    PURPOSE : The aim of this study was to investigate the staining behavior of demineralized enamel infiltrated by low-viscosity resin. METHODS AND MATERIALS : Bovine enamel/dentin cylindrical samples (3 × 2 mm) were assigned into four groups (n=45) according to the enamel treatment: sound enamel (control), demineralization + artificial saliva, demineralization + daily application of 0.05% NaF, demineralization + resin infiltration (Icon, DMG). Artificial white spot lesions were produced in groups with demineralization. After the treatments, color was assessed by spectrophotometry, using the CIE L*a*b* system. The specimens (n=15) were then immersed in deionized water, red wine, or coffee for 10 minutes daily for eight days. Color was measured again, and the specimens were repolished with sandpaper discs. The final color was assessed. Data were analyzed by two-way analysis of variance and Tukey tests (α=0.05). A paired t-test was used for comparison between staining and repolishing conditions. RESULTS : There were significant differences for surface treatment and dye after staining and repolishing. Immersion in wine and coffee resulted in significantly increased color alteration (ΔE) compared with water (p=0.001). The resin-infiltrated group exhibited the highest staining values (p=0.001). The repolishing procedures resulted in significantly decreased color change. The exposure of specimens to colored solutions resulted in significant color alteration. The demineralized enamel treated with resin infiltration showed significantly higher staining than all other tested groups; however, the repolishing of the specimens minimized the staining effect.

  19. "Stained Glass" Landscape Windows

    ERIC Educational Resources Information Center

    Vannata, Janine

    2008-01-01

    Both adults and children alike marvel at the grand vivid stained-glass windows created by American artist Louis Comfort Tiffany. Today he is commonly recognized as one of America's most influential designers and artists throughout the last nineteenth and early twentieth century. In the lesson described in this article, students created their own…

  20. [Application of Warthin-Starry stain, immunohistochemistry and transmission electron microscopy in diagnosis of cat scratch disease].

    PubMed

    Huang, Juan; Dai, Lin; Lei, Song; Liao, Dian-ying; Wang, Xiao-qing; Luo, Tian-you; Chen, Yu; Hang, Zhen-biao; Li, Gan-di; Dong, Dan-dan; Xu, Gang; Gu, Zheng-ce; Hao, Ji-ling; Hua, Ping; He, Lei; Duan, Fang-lei

    2010-04-01

    To evaluate the diagnostic utility of Warthin-Starry silver stain, immunohistochemistry and transmission electron microscopy in the detection of human Bartonella henselae infection and pathologic diagnosis of cat scratch disease (CSD). The paraffin-embedded lymph node tissues of 77 histologically-defined cases of cat scratch disease collected during the period from January, 1998 to December, 2008 were retrieved and studied using Warthin-Starry silver stain (WS stain) and mouse monoclonal antibody against Bartonella henselae (BhmAB stain). Five cases rich in bacteria were selected for transmission electron microscopy. Under electron microscope, the organisms Bartonella henselae appeared polymorphic, round, elliptical, short rod or bacilliform shapes, ranged from 0.489 to 1.110 microm by 0.333 to 0.534 microm and often clustered together. Black short rod-shaped bacilli arranged in chains or clumps were demonstrated in 61.0% (47/77) of CSD by WS stain. The organisms were located outside the cells and lie mainly in the necrotic debris, especially near the nodal capsule. In 72.7% (56/77) of the cases, dot-like, granular as well as few linear positive signals were observed using BhmAB immunostain and showed similar localization. Positive results for both stains were identified in 59.7% (46/77) of the cases. When applying both stains together, Bartonella henselae was observed in 74.0% (57/77) of the case. The difference between the results obtained by WS stain and BhmAB immunostain was of statistical significance (P < 0.05). Bartonella henselae is the causative pathogen of cat scratch disease. WS stain, BhmAB immunostain and transmission electron microscopy are helpful in confirming the histologic diagnosis. Immunostaining using BhmAB can be a better alternative than WS stain in demonstrating the organisms.

  1. Gram stain of skin lesion

    MedlinePlus

    ... during the procedure. Considerations A skin or mucosal culture may be done along with this test. Other ... are examined by other tests or a viral culture. Alternative Names Skin lesion gram stain Images Viral ...

  2. Gloss and Stain Resistance of Ceramic-Polymer CAD/CAM Restorative Blocks.

    PubMed

    Lawson, Nathaniel C; Burgess, John O

    2016-03-01

    To evaluate the gloss and stain resistance of several new ceramic-polymer CAD/CAM blocks Specimens (4 mm) were sectioned from: Enamic (polymer-infused ceramic), LAVA Ultimate (nano-ceramic reinforced polymer), e.max (lithium disilicate), Paradigm C (porcelain), and Paradigm MZ100 (composite). Specimens were wet polished on a polishing wheel to either 320 grit silicon paper (un-polished, N = 8) or 2000 grit silicon carbide papers followed by a 0.05 μm alumina slurry (polished, N = 8). Initial gloss and color (L*a*b*) values were measured. Specimens were stored in a staining solution at 37°C in darkness for 12 days (simulating 1 year). After storage, L*a*b* values re-measured. Change in color was reported as ΔE00 based on the CIEDE2000 formula. Gloss and ΔE00 were analyzed by two-way analysis of variance (ANOVA) (alpha = .05). Separate one-way ANOVA and Tukey post-hoc analyses were performed for both polish conditions and all materials. Two-way ANOVA showed that factors material, polish and their interaction were significant for both gloss and ΔE00 (p < .01). Post-hoc analysis reveals that polished specimens had significantly less color change than un-polished specimens for Paradigm C and LAVA Ultimate. E.max had significantly higher gloss and less color change than all other materials. The composition and polish of CAD/CAM materials affects gloss and stain resistance. Ceramic-polymer hybrid materials can achieve the high gloss required for esthetic restorations. These materials should be polished in order to minimize staining. If polished, all of the tested materials exhibited clinically acceptable color changes at 1 year of simulated staining. (J Esthet Restor Dent 28:S40-S45, 2016). © 2015 Wiley Periodicals, Inc.

  3. Lignin staining ...a limited success in identifying koa growth rings

    Treesearch

    Herbert L. Wick

    1970-01-01

    Among the lignin stains tested in trying to identify growth rings in koa (Acacia koa Gray), phloroglucinol was the most effective. The light colored sapwood of mature trees stained readily, with growth rings apparent. But staining failed to emphasize rings in the dark colored heartwood. Growth rings were not apparent on samples from young fast...

  4. Reliability of a rapid hematology stain for sputum cytology*

    PubMed Central

    Gonçalves, Jéssica; Pizzichini, Emilio; Pizzichini, Marcia Margaret Menezes; Steidle, Leila John Marques; Rocha, Cristiane Cinara; Ferreira, Samira Cardoso; Zimmermann, Célia Tânia

    2014-01-01

    Objective: To determine the reliability of a rapid hematology stain for the cytological analysis of induced sputum samples. Methods: This was a cross-sectional study comparing the standard technique (May-Grünwald-Giemsa stain) with a rapid hematology stain (Diff-Quik). Of the 50 subjects included in the study, 21 had asthma, 19 had COPD, and 10 were healthy (controls). From the induced sputum samples collected, we prepared four slides: two were stained with May-Grünwald-Giemsa, and two were stained with Diff-Quik. The slides were read independently by two trained researchers blinded to the identification of the slides. The reliability for cell counting using the two techniques was evaluated by determining the intraclass correlation coefficients (ICCs) for intraobserver and interobserver agreement. Agreement in the identification of neutrophilic and eosinophilic sputum between the observers and between the stains was evaluated with kappa statistics. Results: In our comparison of the two staining techniques, the ICCs indicated almost perfect interobserver agreement for neutrophil, eosinophil, and macrophage counts (ICC: 0.98-1.00), as well as substantial agreement for lymphocyte counts (ICC: 0.76-0.83). Intraobserver agreement was almost perfect for neutrophil, eosinophil, and macrophage counts (ICC: 0.96-0.99), whereas it was moderate to substantial for lymphocyte counts (ICC = 0.65 and 0.75 for the two observers, respectively). Interobserver agreement for the identification of eosinophilic and neutrophilic sputum using the two techniques ranged from substantial to almost perfect (kappa range: 0.91-1.00). Conclusions: The use of Diff-Quik can be considered a reliable alternative for the processing of sputum samples. PMID:25029648

  5. Unsupervised color normalisation for H and E stained histopathology image analysis

    NASA Astrophysics Data System (ADS)

    Celis, Raúl; Romero, Eduardo

    2015-12-01

    In histology, each dye component attempts to specifically characterise different microscopic structures. In the case of the Hematoxylin-Eosin (H&E) stain, universally used for routine examination, quantitative analysis may often require the inspection of different morphological signatures related mainly to nuclei patterns, but also to stroma distribution. Nevertheless, computer systems for automatic diagnosis are often fraught by color variations ranging from the capturing device to the laboratory specific staining protocol and stains. This paper presents a novel colour normalisation method for H&E stained histopathology images. This method is based upon the opponent process theory and blindly estimates the best color basis for the Hematoxylin and Eosin stains without relying on prior knowledge. Stain Normalisation and Color Separation are transversal to any Framework of Histopathology Image Analysis.

  6. Histological staining methods preparatory to laser capture microdissection significantly affect the integrity of the cellular RNA.

    PubMed

    Wang, Hongyang; Owens, James D; Shih, Joanna H; Li, Ming-Chung; Bonner, Robert F; Mushinski, J Frederic

    2006-04-27

    Gene expression profiling by microarray analysis of cells enriched by laser capture microdissection (LCM) faces several technical challenges. Frozen sections yield higher quality RNA than paraffin-imbedded sections, but even with frozen sections, the staining methods used for histological identification of cells of interest could still damage the mRNA in the cells. To study the contribution of staining methods to degradation of results from gene expression profiling of LCM samples, we subjected pellets of the mouse plasma cell tumor cell line TEPC 1165 to direct RNA extraction and to parallel frozen sectioning for LCM and subsequent RNA extraction. We used microarray hybridization analysis to compare gene expression profiles of RNA from cell pellets with gene expression profiles of RNA from frozen sections that had been stained with hematoxylin and eosin (H&E), Nissl Stain (NS), and for immunofluorescence (IF) as well as with the plasma cell-revealing methyl green pyronin (MGP) stain. All RNAs were amplified with two rounds of T7-based in vitro transcription and analyzed by two-color expression analysis on 10-K cDNA microarrays. The MGP-stained samples showed the least introduction of mRNA loss, followed by H&E and immunofluorescence. Nissl staining was significantly more detrimental to gene expression profiles, presumably owing to an aqueous step in which RNA may have been damaged by endogenous or exogenous RNAases. RNA damage can occur during the staining steps preparatory to laser capture microdissection, with the consequence of loss of representation of certain genes in microarray hybridization analysis. Inclusion of RNAase inhibitor in aqueous staining solutions appears to be important in protecting RNA from loss of gene transcripts.

  7. Histological staining methods preparatory to laser capture microdissection significantly affect the integrity of the cellular RNA

    PubMed Central

    Wang, Hongyang; Owens, James D; Shih, Joanna H; Li, Ming-Chung; Bonner, Robert F; Mushinski, J Frederic

    2006-01-01

    Background Gene expression profiling by microarray analysis of cells enriched by laser capture microdissection (LCM) faces several technical challenges. Frozen sections yield higher quality RNA than paraffin-imbedded sections, but even with frozen sections, the staining methods used for histological identification of cells of interest could still damage the mRNA in the cells. To study the contribution of staining methods to degradation of results from gene expression profiling of LCM samples, we subjected pellets of the mouse plasma cell tumor cell line TEPC 1165 to direct RNA extraction and to parallel frozen sectioning for LCM and subsequent RNA extraction. We used microarray hybridization analysis to compare gene expression profiles of RNA from cell pellets with gene expression profiles of RNA from frozen sections that had been stained with hematoxylin and eosin (H&E), Nissl Stain (NS), and for immunofluorescence (IF) as well as with the plasma cell-revealing methyl green pyronin (MGP) stain. All RNAs were amplified with two rounds of T7-based in vitro transcription and analyzed by two-color expression analysis on 10-K cDNA microarrays. Results The MGP-stained samples showed the least introduction of mRNA loss, followed by H&E and immunofluorescence. Nissl staining was significantly more detrimental to gene expression profiles, presumably owing to an aqueous step in which RNA may have been damaged by endogenous or exogenous RNAases. Conclusion RNA damage can occur during the staining steps preparatory to laser capture microdissection, with the consequence of loss of representation of certain genes in microarray hybridization analysis. Inclusion of RNAase inhibitor in aqueous staining solutions appears to be important in protecting RNA from loss of gene transcripts. PMID:16643667

  8. Ulex Europaeus lectin and anti-CD31 staining in squamous cell carcinoma of the uterine cervix: potential prognostic markers.

    PubMed

    Davidson, B; Goldberg, I; Gotlieb, W H; Lerner-Geva, L; Ben-Baruch, G; Kopolovic, J

    1998-07-01

    Seventy-five squamous cell carcinomas of the uterine cervix and 10 controls were stained for Ulex Europaeus lectin 1 (UEA-1) and anti-CD31, and the results were analyzed with respect to patient age, clinical stage, tumor grade, and survival during a follow-up period of 1 to 13 years. The patients' mean age at the time of diagnosis was 47.8 years (range, 27 to 83). Seventeen patients died of disease, 2 had disease recurrence, and 51 patients remained free of disease; 5 patients were lost to follow-up. Twenty-eight cases (37.3%) showed focal membranous staining for UEA-1 and 9 cases (12%) showed a diffuse pattern; 38 cases (50.7%) were UEA-1 negative. Poor survival was related to diffuse membranous UEA-1 immunoreactivity (p = 0.02), age (p = 0.014), grade (p = 0.02), and stage (p = 0.0002). CD31-positive neoplastic cells displayed a cytoplasmic pattern. Fifteen cases (20%) had diffuse staining and another 15 (20%) stained focally; 45 cases (60%) were CD31-negative. The adjacent nonneoplastic epithelium and all 10 controls were uniformly negative for CD31. Variable staining of the endocervical epithelium and weak or negative staining of ectocervical epithelium for UEA-1 were observed. However, the epithelium in all controls was negative for UEA-1. Poor survival was related to both focal and diffuse staining for CD31 (p = 0.01 and p = 0.03, respectively). Staining by both UEA-1 and anti-CD31 retained its correlation with survival after exclusion of stage la tumors.

  9. Acetylcholinesterase and Nissl staining in the same histological section.

    PubMed

    Shipley, M T; Ennis, M; Behbehani, M M

    1989-12-18

    Acetylcholinesterase (AChE) enzyme histochemistry and Nissl staining are commonly utilized in neural architectonic studies. However, the opaque reaction deposit produced by the most commonly used AChE histochemical methods is not compatible with satisfactory Nissl staining. As a result, precise correlation of AChE and Nissl staining necessitates time-consuming comparisons of adjacent sections which may have differential shrinkage. Here, we have modified the Koelle-Friedenwald histochemical reaction for AChE by omitting the final intensification steps. The modified reaction yields a non-opaque reaction product that is selectively visualized by darkfield illumination. This non-intensified darkfield AChE (NIDA) reaction allows clear visualization of Nissl staining in the same histological section. This combined AChE-Nissl method greatly facilitates detailed correlation of enzyme and cytoarchitectonic organization.

  10. A double blind randomised controlled clinical trial comparing a novel anti-stain and calculus reducing dentifrice with a standard fluoride dentifrice.

    PubMed

    Jowett, Adrian K; Marlow, Ian; Rawlinson, Andrew

    2013-04-01

    This clinical trial tested the anti-stain efficacy at 3 and 6 months of a novel, sodium polyaspartate-containing, anti-stain dentifrice. In addition, the efficacy of the new dentifrice in controlling gingival inflammation and inhibition of calculus deposition was tested. Participants were recruited to this double blind randomised control clinical trial, and allocated to either test or control groups. The presence of stain and calculus were entry criteria. Measurements of stain, calculus and gingival inflammation were recorded using the Shaw and Murray Stain score, Volpe-Manhold Calculus score and the Modified Gingival Index respectively. Measurements were made at baseline, prior to the removal of stain and calculus, and after 3 and 6 months. Missing data were imputed by and the outcomes were analysed using univariate analysis. At three months, toothpaste containing sodium polyaspartate was better (difference of mean 1.13 with SEM 0.57) than control for the control of dental stain (p<0.05). Stain scores also showed a trend in favour of the test product (difference of mean 1.03 with SEM 0.78) at six months (p>0.05). There was no difference between toothpastes with respect to calculus deposition or gingival inflammation. Toothpaste containing sodium polyaspartate was more effective than a control toothpaste at preventing deposition of dental stain for 3 months after professional tooth cleaning but showed no significant effect at 6 months. Sodium polyaspartate toothpaste was more effective than a control toothpaste at preventing dental stain formation and maybe helpful in controlling staining between episodes of scaling and polishing. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. 7 CFR 3201.87 - Wood and concrete stains.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 15 2013-01-01 2013-01-01 false Wood and concrete stains. 3201.87 Section 3201.87... Designated Items § 3201.87 Wood and concrete stains. (a) Definition. Products that are designed to be applied as a finish for concrete and wood surfaces and that contain dyes or pigments to change the color...

  12. 7 CFR 3201.87 - Wood and concrete stains.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 15 2014-01-01 2014-01-01 false Wood and concrete stains. 3201.87 Section 3201.87... Designated Items § 3201.87 Wood and concrete stains. (a) Definition. Products that are designed to be applied as a finish for concrete and wood surfaces and that contain dyes or pigments to change the color...

  13. The Bacterial Endospore Stain on Schaeffer Fulton using Variation of Methylene Blue Solution

    NASA Astrophysics Data System (ADS)

    Oktari, A.; Supriatin, Y.; Kamal, M.; Syafrullah, H.

    2017-02-01

    Endospores staining is the type of staining to recognize the presence spore in bacterial vegetative cells. The bacterial endospores need a staining which can penetrate wall thickness of spore bacteria. A method of endospores staining is Schaeffer Fulton method that used Malachite Green. It is an alkaline substance staining that can staining the spore bacteria. In this research, it have found the alternative staining that can replace Malachite Green solution in spore bacterial stain. The alternative staining used is Methylene Blue solution (0,5 %, 0,7%, and 1% concentration) with pH variation (10, 11, and 12), and varyous heating time (3, 4, and 5 minutes). The all treatments staining have been effect on bacterial spores staining results. The warming time greatly affect the dye to penetrate the walls of bacterial spores, this can be seen in the results with various concentration at pH 10, indicates that the not long warm-up time 3 and 4 minutes, bacterial spores are not stained, while in the longer heating time is 5 minutes bacterial spores stained. This is caused because the longer heating time can make the pores of spore wall is open so that can facilitate the dye to get into the bacterial spores.

  14. Image analysis assisted study of mitotic figures in oral epithelial dysplasia and squamous cell carcinoma using differential stains.

    PubMed

    Tandon, Ankita; Singh, Narendra Nath; Brave, V R; Sreedhar, Gadiputi

    2016-11-01

    Mitosis is a process of cell division resulting in two genetically equivalent daughter cells. Excessive proliferation of cells due to mitosis is the hallmark in pre cancer and cancer. This study was conducted to count the number of mitotic figures in normal oral mucosa, oral epithelial dysplasia and squamous cell carcinoma in both Hematoxylin and Eosin (H&E) and Crystal Violet stained sections. Also the overall number of mitotic figures with both stains were compared along with the evaluation of staining efficacy of both the stains. The present study was conducted on 20 specimens each of the three categories. These were further divided into two groups for staining with H&E and with 1% Crystal Violet respectively. Images were captured and analyzed using image analysis software Dewinter Biowizard 4.1. Comparison of mitotic figure count in three categories in sections stained with both stains showed statistically significant difference ( p  < 0.001). The mean number of mitotic figures seen in Crystal Violet reagent were significantly higher as seen in H&E stain ( p  < 0.001). The overall diagnostic efficacy of Crystal Violet was 87.6%. Crystal Violet scored over H&E stain and also helped to better appreciate metaphases in Squamous cell carcinoma and telophases in dysplasia. Number of mitotic figures progressively increase with the advancement of the pathology. Use of 1% Crystal Violet provides better appreciation of mitotic figures and can be employed as a selective stain in routine histopathology.

  15. Comparison of Immunohistochemistry and Direct Sanger Sequencing for Detection of the BRAFV600E Mutation in Thyroid Neoplasm

    PubMed Central

    Oh, Hye-Seon; Kwon, Hyemi; Park, Suyeon; Kim, Mijin; Jeon, Min Ji; Kim, Tae Yong; Shong, Young Kee; Kim, Won Bae; Choi, Jene

    2018-01-01

    Background The BRAFV600E mutation is the most common genetic alteration identified in papillary thyroid carcinoma (PTC). Because of its costs effectiveness and sensitivity, direct Sanger sequencing has several limitations. The aim of this study was to evaluate the efficiency of immunohistochemistry (IHC) as an alternative method to detect the BRAFV600E mutation in preoperative and postoperative tissue samples. Methods We evaluated 71 patients who underwent thyroid surgery with the result of direct sequencing of the BRAFV600E mutation. IHC staining of the BRAFV600E mutation was performed in 49 preoperative and 23 postoperative thyroid specimens. Results Sixty-two patients (87.3%) had PTC, and of these, BRAFV600E was confirmed by direct sequencing in 57 patients (91.9%). In 23 postoperative tissue samples, the BRAFV600E mutation was detected in 16 samples (70%) by direct sequencing and 18 samples (78%) by IHC. In 24 fine needle aspiration (FNA) samples, BRAFV600E was detected in 18 samples (75%) by direct sequencing and 16 samples (67%) by IHC. In 25 core needle biopsy (CNB) samples, the BRAFV600E mutation was detected in 15 samples (60%) by direct sequencing and 16 samples (64%) by IHC. The sensitivity and specificity of IHC for detecting the BRAFV600E mutation were 77.8% and 66.7% in FNA samples and 99.3% and 80.0% in CNB samples. Conclusion IHC could be an alternative method to direct Sanger sequencing for BRAFV600E mutation detection both in postoperative and preoperative samples. However, application of IHC to detect the BRAFV600E mutation in FNA samples is of limited value compared with direct sequencing. PMID:29388401

  16. Immunohistochemistry practices of cytopathology laboratories: a survey of participants in the College of American Pathologists Nongynecologic Cytopathology Education Program.

    PubMed

    Fischer, Andrew H; Schwartz, Mary R; Moriarty, Ann T; Wilbur, David C; Souers, Rhona; Fatheree, Lisa; Booth, Christine N; Clayton, Amy C; Kurtyz, Daniel F I; Padmanabhan, Vijayalakshmi; Crothers, Barbara A

    2014-09-01

    Immunohistochemistry (IHC) is important for cytology but poses special challenges because preanalytic conditions may differ from the conditions of IHC-positive controls. To broadly survey cytology laboratories to quantify preanalytic platforms for cytology IHC and identify problems with particular platforms or antigens. To discover how validation guidelines for HER2 testing have affected cytology. A voluntary survey of cytology IHC practices was sent to 1899 cytology laboratories participating in the College of American Pathologists Nongynecologic Cytopathology Education Program in the fall of 2009. A total of 818 laboratories (43%) responded to the survey by April 2010. Three hundred fourty-five of 791 respondents (44%) performed IHC on cytology specimens. Seventeen different fixation and processing platforms prior to antibody reaction were reported. A total of 59.2% of laboratories reported differences between the platforms for cytology specimens and positive controls, but most (155 of 184; 84%) did not alter antibody dilutions or antigen retrieval for cytology IHC. When asked to name 2 antibodies for which staining conditions differed between cytology and surgical samples, there were 18 responses listing 14 antibodies. A total of 30.6% of laboratories performing IHC offered HER2 testing before publication of the 2007 College of American Pathologists/American Society of Clinical Oncologists guidelines, compared with 33.6% afterward, with increased performance of testing by reference laboratories. Three laboratories validated a nonformalin HER2 platform. The platforms for cytology IHC and positive controls differ for most laboratories, yet conditions are uncommonly adjusted for cytology specimens. Except for the unsuitability of air-dried smears for HER2 testing, the survey did not reveal evidence of systematic problems with any antibody or platform.

  17. Should gram stains have a role in diagnosing hip arthroplasty infections?

    PubMed

    Johnson, Aaron J; Zywiel, Michael G; Stroh, D Alex; Marker, David R; Mont, Michael A

    2010-09-01

    The utility of Gram stains in diagnosing periprosthetic infections following total hip arthroplasty has recently been questioned. Several studies report low sensitivity of the test, and its poor ability to either confirm or rule out infection in patients undergoing revision total hip arthroplasty. Despite this, many institutions including that of the senior author continue to perform Gram stains during revision total hip arthroplasty. We assessed the sensitivity, specificity, accuracy, and positive and negative predictive values of Gram stains from surgical-site samplings taken from procedures on patients with both infected and aseptic revision total hip arthroplasties. A review was performed on patients who underwent revision total hip arthroplasty between 2000 and 2007. Eighty-two Gram stains were performed on patients who had infected total hip arthroplasties and underwent revision procedures. Additionally, of the 410 revision total hip arthroplasties performed on patients who were confirmed infection-free, 120 Gram stains were performed. Patients were diagnosed as infected using multiple criteria at the time of surgery. Sensitivity, specificity, positive and negative predictive values, and accuracy were calculated from these Gram stain results. The Gram stain demonstrated a sensitivity and specificity of 9.8% and 100%, respectively. In this series, the Gram stain had a negative predictive value of 62%, a positive predictive value of 100%, and an accuracy of 63%. Gram stains obtained from surgical-site samples had poor sensitivity and poor negative predictive value. Based on these findings, as well as those of other authors, we believe that Gram stains should no longer be considered for diagnosing infections in revision total hip arthroplasty. Level III, diagnostic study. See Guidelines for Authors for a complete description of levels of evidence.

  18. The value of intraoperative Gram stain in revision spine surgery.

    PubMed

    Shifflett, Grant D; Nwachukwu, Benedict U; Bjerke-Kroll, Benjamin T; Kueper, Janina; Koltsov, Jayme B; Sama, Andrew A; Girardi, Federico P; Cammisa, Frank P; Hughes, Alexander P

    2015-10-01

    Intraoperative cultures and Gram stains are often obtained in cases of revision spine surgery even when clinical signs of infection are not present. The clinical utility and cost-effectiveness of this behavior remain unproven. The aim was to evaluate the clinical utility and cost-effectiveness of routine intraoperative Gram stains in revision spine surgery. This was a retrospective clinical review performed at an academic center in an urban setting. One hundred twenty-nine consecutive adult revision spine surgeries were performed. The outcome measures included intraoperative Gram stains. We retrospectively reviewed the records of 594 consecutive revision spine surgeries performed by four senior surgeons between 2008 and 2013 to identify patients who had operative cultures and Gram stains performed. All revision cases including cervical, thoracic, and lumbar fusion and non-fusion, with and without instrumentation were reviewed. One hundred twenty-nine (21.7%) patients had operative cultures obtained and were included in the study. The most common primary diagnosis code at the time of revision surgery was pseudarthrosis, which was present in 41.9% of cases (54 of 129). Infection was the primary diagnosis in 10.1% (13 of 129) of cases. Operative cultures were obtained in 129 of 595 (21.7%) cases, and 47.3% (61 of 129) were positive. Gram stains were performed in 98 of 129 (76.0%) cases and were positive in 5 of 98 (5.1%) cases. Overall, there was no correlation between revision diagnosis and whether or not a Gram stain was obtained (p=.697). Patients with a history of prior instrumentation were more likely to have a positive Gram stain (p<.0444). Intraoperative Gram staining was found to have a sensitivity of 10.9% (confidence interval [CI] 3.9%-23.6%) and specificity of 100% (CI 93.1%-100%). The positive and negative predictive values were 100% (CI 48.0%-100%) and 57.3% (CI 45.2%-66.2%), respectively. Kappa coefficient was calculated to be 0.1172 (CI 0

  19. Exploring methods for prevention of oxidative stain in soft maple

    Treesearch

    Michael C. Wiemann; Richard D. Bergman; Mark Knaebe; Scott A. Bowe

    2009-01-01

    Interior gray enzymatic oxidative stain for white woods such as maple has plagued the wood industry for many years because methods that have been found to reduce stain are hard to scale up to industrial levels. We examined possible alternative treatments to eliminate stain in soft maple (Acer rubrum L.), and found that exposure to sulfur dioxide gas eliminates interior...

  20. Laser treatment of port-wine stains

    PubMed Central

    Brightman, Lori A; Geronemus, Roy G; Reddy, Kavitha K

    2015-01-01

    Port-wine stains are a type of capillary malformation affecting 0.3% to 0.5% of the population. Port-wine stains present at birth as pink to erythematous patches on the skin and/or mucosa. Without treatment, the patches typically darken with age and may eventually develop nodular thickening or associated pyogenic granuloma. Laser and light treatments provide improvement through selective destruction of vasculature. A variety of vascular-selective lasers may be employed, with the pulsed dye laser being the most common and well studied. Early treatment produces more optimal results. Advances in imaging and laser treatment technologies demonstrate potential to further improve clinical outcomes. PMID:25624768

  1. Circular Mixture Modeling of Color Distribution for Blind Stain Separation in Pathology Images.

    PubMed

    Li, Xingyu; Plataniotis, Konstantinos N

    2017-01-01

    In digital pathology, to address color variation and histological component colocalization in pathology images, stain decomposition is usually performed preceding spectral normalization and tissue component segmentation. This paper examines the problem of stain decomposition, which is a naturally nonnegative matrix factorization (NMF) problem in algebra, and introduces a systematical and analytical solution consisting of a circular color analysis module and an NMF-based computation module. Unlike the paradigm of existing stain decomposition algorithms where stain proportions are computed from estimated stain spectra using a matrix inverse operation directly, the introduced solution estimates stain spectra and stain depths via probabilistic reasoning individually. Since the proposed method pays extra attentions to achromatic pixels in color analysis and stain co-occurrence in pixel clustering, it achieves consistent and reliable stain decomposition with minimum decomposition residue. Particularly, aware of the periodic and angular nature of hue, we propose the use of a circular von Mises mixture model to analyze the hue distribution, and provide a complete color-based pixel soft-clustering solution to address color mixing introduced by stain overlap. This innovation combined with saturation-weighted computation makes our study effective for weak stains and broad-spectrum stains. Extensive experimentation on multiple public pathology datasets suggests that our approach outperforms state-of-the-art blind stain separation methods in terms of decomposition effectiveness.

  2. In-office bleaching efficacy on stain removal from CAD/CAM and direct resin composite materials.

    PubMed

    Alharbi, Amal; Ardu, Stefano; Bortolotto, Tissiana; Krejci, Ivo

    2018-01-01

    To evaluate the efficacy of in-office bleaching on stain removal from stained resin composite and ceramic computer-assisted design/computer-assisted manufacturing (CAD/CAM) blocks and direct resin composites. Forty disk-shaped samples were fabricated from each of nine materials: six CAD/CAM (VITABLOCS Mark II, Paradigm MZ100, Exp Vita Hybrid Ceramic, VITA ENAMIC, Exp Kerr, and LAVA Ultimate) and three direct resin composites (Filtek Supreme, Venus Diamond, and Filtek Silorane). Samples were randomly divided into five groups (n = 8), each stained with a particular staining solution. Using a calibrated spectrophotometer and a black background, L*a*b* values were assessed before and after 120 days of staining. Samples were subjected to in-office bleaching using 40% hydrogen peroxide gel for one hour. At subsequent assessment, color change (ΔE) was calculated as the difference between L*a*b* values. Both ANOVA and the Duncan test were used to identify differences between groups (α = 0.05). Bleaching resulted in significant differences in ΔE values for all materials (P < .001). Bleaching efficacy was highly influenced by material composition and staining solution. Residual color values after bleaching for ceramic and hybrid ceramics ranged from -0.49 to 2.35, within the clinically acceptable maximum of 3.3. Values after bleaching for resin-based CAD/CAM ranged from -0.7 to 7.08 while direct resin composites values ranged from -1.47 to 25.13. Coffee left the greatest residual color on all materials. Based on material nature, 40% hydrogen peroxide bleaching can remove staining. The new resin-based CAD/CAM blocks showed promising results in terms of color stability. Bleaching using 40% hydrogen peroxide can be an effective method to remove stains from dental restorations. In this way, restoration replacement as a result of discoloration may no longer be necessary. © 2017 Wiley Periodicals, Inc.

  3. A new technique for Gram staining paraffin-embedded tissue.

    PubMed Central

    Engbaek, K; Johansen, K S; Jensen, M E

    1979-01-01

    Five techniques for Gram staining bacteria in paraffin sections were compared on serial sections of pulmonary tissues from eight bacteriological necropsies. Brown and Hopp's method was the most satisfactory for distinguishing Gram-positive and Gram-negative bacteria. However, this method cannot be recommended as the preparations were frequently overstained, and the Gram-negative bacteria were stained indistinctly. A modification of Brown and Hopps' method was developed which stains larger numbers of Gram-negative bacteria and differentiates well between different cell types and connective tissue, and there is no risk of overstaining. PMID:86548

  4. Influence of orthodontic adhesives and clean-up procedures on the stain susceptibility of enamel after debonding.

    PubMed

    Joo, Hyun-Jin; Lee, Yong-Keun; Lee, Dong-Yul; Kim, Yae-Jin; Lim, Yong-Kyu

    2011-03-01

    To determine the influence of the type of orthodontic adhesive system, such as conventional acid-etching (CE) and self-etching primers (SEPs), on the stain susceptibility of enamel surface after debonding. Effects of clean-up procedures on the enamel surface were also determined. Two types and four brands of adhesive systems were investigated using 135 human premolars. Unbonded teeth were used as controls. Three-dimensional scanning of the enamel surface was performed before bracket bonding, after debonding, and after clean-up procedures. The color of each tooth was measured before bracket bonding and again after debonding and clean-up procedures. This was followed by methylene blue staining. The stain susceptibility of the enamel surface was measured after finishing only (F-condition) and after finishing/polishing (FP-condition). After debonding, the amount of residual adhesive resins in CE materials was greater than that in SEP materials. For the F-condition, staining color change in SEP materials was significantly higher than that in CE materials. For the FP-condition, staining color change in both CE and SEP materials was not different from those of the control. The SEP system would show less stain susceptibility if the thin residual adhesive resin layer after debonding is removed by polishing.

  5. Fluorogenic Ag+–Tetrazolate Aggregation Enables Efficient Fluorescent Biological Silver Staining

    PubMed Central

    Xie, Sheng; Wong, Alex Y. H.; Kwok, Ryan T. K.; Li, Ying; Su, Huifang; Lam, Jacky W. Y.

    2018-01-01

    Abstract Silver staining, which exploits the special bioaffinity and the chromogenic reduction of silver ions, is an indispensable visualization method in biology. It is a most popular method for in‐gel protein detection. However, it is limited by run‐to‐run variability, background staining, inability for protein quantification, and limited compatibility with mass spectroscopic (MS) analysis; limitations that are largely attributed to the tricky chromogenic visualization. Herein, we reported a novel water‐soluble fluorogenic Ag+ probe, the sensing mechanism of which is based on an aggregation‐induced emission (AIE) process driven by tetrazolate‐Ag+ interactions. The fluorogenic sensing can substitute the chromogenic reaction, leading to a new fluorescence silver staining method. This new staining method offers sensitive detection of total proteins in polyacrylamide gels with a broad linear dynamic range and robust operations that rival the silver nitrate stain and the best fluorescent stains. PMID:29575702

  6. Fluorescent staining for leukocyte chemotaxis. Eosinophil-specific fluorescence with aniline blue.

    PubMed

    McCrone, E L; Lucey, D R; Weller, P F

    1988-11-10

    To overcome problems associated with the quantitation of human eosinophil chemotaxis in micropore filters, we have developed a fluorescent method of specifically staining eosinophils in chemotactic filters. A neutral solution of aniline blue yielded bright green fluorescent staining of the cytoplasmic granules of eosinophils. Other leukocytes and contaminating neutrophils potentially present with eosinophils did not fluoresce with aniline blue. The fluorescent staining eosinophils within filters provided bright, non-fading images that facilitated visual microscopic counting and were of sufficiently high contrast, unlike those with conventional eosinophil stains, to allow image analyzer based enumeration of eosinophil chemotactic responses at levels through the filters. Although not cell type-specific, congo red and ethidium bromide also provided high contrast, fluorescent images of all leukocyte types within chemotactic filters. Fluorescent staining with aniline blue constitutes a rapid, stable and eosinophil-specific stain that facilitates the visual or image analyzer-based quantitation of eosinophil chemotaxis.

  7. Redefining Perineural Invasion: Integration of Biology With Clinical Outcome.

    PubMed

    Schmitd, Ligia B; Beesley, Lauren J; Russo, Nickole; Bellile, Emily L; Inglehart, Ronald C; Liu, Min; Romanowicz, Genevieve; Wolf, Gregory T; Taylor, Jeremy M G; D'Silva, Nisha J

    2018-05-22

    A diagnosis of perineural invasion (PNI), defined as cancer within or surrounding at least 33% of the nerve, leads to selection of aggressive treatment in squamous cell carcinoma (SCC). Recent mechanistic studies show that cancer and nerves interact prior to physical contact. The purpose of this study was to explore cancer-nerve interactions relative to clinical outcome. Biopsy specimens from 71 patients with oral cavity SCC were stained with hematoxylin and eosin and immunohistochemical (IHC; cytokeratin, S100, GAP43, Tuj1) stains. Using current criteria, PNI detection was increased with IHC. Overall survival (OS) tended to be poor for patients with PNI (P = .098). OS was significantly lower for patients with minimum tumor-nerve distance smaller than 5 μm (P = .011). The estimated relative death rate decreased as the nerve-tumor distance increased; there was a gradual drop off in death rate from distance equal to zero that stabilized around 500 μm. In PNI-negative patients, nerve diameter was significantly related to OS (HR 2.88, 95%CI[1.11,7.49]). Among PNI-negative nerves, larger nerve-tumor distance and smaller nerve diameter were significantly related to better OS, even when adjusting for T-stage and age (HR 0.82, 95% CI[0.72,0.92]; HR 1.27, 95% CI[1.00,1.62], respectively). GAP43, a marker for neuronal outgrowth, stained less than Tuj1 in nerves at greater distances from tumor (OR 0.76, 95% CI[0.73,0.79]); more GAP43 staining was associated with PNI. Findings from a small group of patients suggest that nerve parameters other than presence of PNI can influence outcome and that current criteria of PNI need to be re-evaluated to integrate recent biological discoveries. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  8. Brilliant Blue G double staining enhances successful internal limiting membrane peeling with minimal adverse effect by low cellular permeability into live cells.

    PubMed

    Hisatomi, Toshio; Notomi, Shoji; Tachibana, Takashi; Oishi, Seiichiro; Asato, Ryo; Yamashita, Takehiro; Murakami, Yusuke; Ikeda, Yasuhiro; Enaida, Hiroshi; Sakamoto, Taiji; Ishibashi, Tatsuro

    2015-02-01

    Brilliant Blue G is used as a surgical adjuvant for retinal surgery. Although BBG double or multiple staining was reported, the effectiveness and safety of repeated staining is still elusive. To further examine the effectiveness and safety, we examined BBG in clinical cases in vivo, primary cell culture in vitro, and surgically resected specimen ex vivo. A retrospective interventional case series with in vitro and ex vivo studies were performed. Vitrectomy was performed in 28 cases of epiretinal membrane with BBG single to multiple staining. The surgically resected membranes were stained by BBG with or without cellular fixation. Primary cell cultures were examined with BBG and live/death cell markers, such as Calcein AM and TUNEL. Single staining provided satisfactory staining in seven cases. Double or multiple staining substantially visualized internal limiting membrane (21 cases), especially the edges of remaining internal limiting membrane (11 cases). Adverse retinal staining was not noted and the final visual acuity showed no difference with multiple staining. The live cells barely stained with BBG, while some dead cells were stained. Brilliant Blue G multiple staining substantially enhanced the visualization of internal limiting membrane. The absence of abnormal staining supports the safety of repeated BBG staining.

  9. Washout of heme-containing proteins dramatically improves tetrazolium-based infarct staining.

    PubMed

    Pitts, Kelly R; Stiko, Ann; Buetow, Bernard; Lott, Fred; Guo, Ping; Virca, Duke; Toombs, Christopher F

    2007-01-01

    Methods to determine infarct size following ischemia-reperfusion injury include gross staining with triphenyltetrazolium chloride (TTC) and perfusion of colored dyes to demarcate the non-ischemic zone. Infarcted tissue (INF) can typically appear a mottled tan to brownish color, making a border between INF and TTC-positive tissue difficult to discern. Previous work in our lab indicated that following TTC staining, prolonged washing of thick sections dramatically sharpened this boundary. Adult rats underwent 30 min ischemia via LAD ligation and reperfusion/recovery over 24 h. Hearts were then harvested, thick-sectioned, and stained with TTC. Stained sections were stored in PBS at 4 degrees C for up to 3 weeks. Histology on thin sections from infarcted hearts fixed directly after harvest revealed extensive hemorrhage within the INF. However, this hemorrhage is washed out when hearts are stored in PBS for 3 weeks. SDS-PAGE of PBS samples taken at 1, 2, and 3 weeks showed a low molecular weight band appearing over time. Peptide sequencing revealed the presence of several proteins including the heme-containing proteins (HCPs) hemoglobin, cytochrome c, and myoglobin. The loss of HCPs from thick sections to PBS corresponded with the blanching of the previously mottled INF within each section. HPLC analysis of these samples confirmed the loss of HCPs contributes to INF whitening. Further, analysis of infarct size values derived from heart slices with or without HCPs showed a significant decrease in measurement error when values were derived from slices without HCPs. These data suggest that HCPs in the heart tissue contribute to the non-uniform and discolored appearance of the INF, and that washout of these proteins produces an INF more easily distinguished from neighboring non-infarcted tissue. This method greatly reduces the error associated with infarct measurements and improves the analysis of the effects of drug treatments and other interventions designed to impact

  10. Evaluation of Papanicolaou stain for studying micronuclei in buccal cells under field conditions.

    PubMed

    Ayyad, Sohair B A; Israel, Ebenezer; El-Setouhy, Maged; Nasr, Ghada Radwan; Mohamed, Mostafa K; Loffredo, Christopher A

    2006-01-01

    To compare Papanicolaou (Pap) and May-Grünwald Giemsa (MGG) stain as 2 techniques for staining for buccal mucosal cells to detect micronuclei (MN) infield studies. Eighty cytologic smears (2 per individual) were taken from the buccal mucosa of 40 cigarette smokers recruited at a rural village in Egypt. Forty smears were stained with Pap stain and 40 with MGG stain. All were assessed for cellularity and scored for MN. Pap stain was faster and easier to process and transport in the field study than was MGG stain. Regarding MGG smears, bacteria and cell debris masked the MN as compared to Pap smears, in which the fixative destroyed the bacteria and made the cell boundaries clearly demarcated. Using Pap stain, MN were seen easily in transparent cytoplasm. Pap stain is the preferred method infield studies for scoring and detecting MN in cells of buccal mucosa.

  11. Microscopic diagnosis of vulvovaginal candidiasis in stained vaginal smears by Dutch general practitioners.

    PubMed

    Engberts, Marian K; Goedbloed, Annelize F; van Haaften, Maarten; van Haaften, Mathilde; Boon, Mathilde E; Boon, Maarten E; Heintz, Peter M

    2007-01-01

    To determine the accuracy of the microscopic diagnosis of vulvovaginal candidiasis (presence of [pseudo] hyphae and blastospores) in stained vaginal smears in clinical practice. General practitioners trained in diagnosing vulvovaginal candidiasis performed microscopy of 324 stained vaginal smears. These smears were sent to the pathologist for confirmation of the microscopic diagnosis of the clinician; cytologic diagnosis by the pathologist was considered the gold standard. In 104 of the 342 cases Candida was established by the pathologist. The clinicians made 24 false positive and 50 false negative diagnoses of Candida. Sensitivity and specificity of the microscopic diagnoses of the clinicians were 52% and 89%, respectively. The most frequent reason for a false positive diagnosis was presence of hairs, whereas the most frequent reason for a false negative diagnosis was understaining of the smear. This study shows that even in stained smears it is difficult for clinicians to recognize blastospores and (pseudo)hyphae. Efforts are clearly needed to improve the quality of the clinical diagnosis of vulvovaginal candidiasis.

  12. Microglial Activation Correlates with Disease Progression and Upper Motor Neuron Clinical Symptoms in Amyotrophic Lateral Sclerosis

    PubMed Central

    Brettschneider, Johannes; Toledo, Jon B.; Van Deerlin, Vivianna M.; Elman, Lauren; McCluskey, Leo; Lee, Virginia M.-Y.; Trojanowski, John Q.

    2012-01-01

    Background/Aims We evaluated clinicopathological correlates of upper motor neuron (UMN) damage in amyotrophic lateral sclerosis (ALS), and analyzed if the presence of the C9ORF72 repeat expansion was associated with alterations in microglial inflammatory activity. Methods Microglial pathology was assessed by IHC with 2 different antibodies (CD68, Iba1), myelin loss by Kluver-Barrera staining and myelin basic protein (MBP) IHC, and axonal loss by neurofilament protein (TA51) IHC, performed on 59 autopsy cases of ALS including 9 cases with C9ORF72 repeat expansion. Results Microglial pathology as depicted by CD68 and Iba1 was significantly more extensive in the corticospinal tract (CST) of ALS cases with a rapid progression of disease. Cases with C9ORF72 repeat expansion showed more extensive microglial pathology in the medulla and motor cortex which persisted after adjusting for disease duration in a logistic regression model. Higher scores on the clinical UMN scale correlated with increasing microglial pathology in the cervical CST. TDP-43 pathology was more extensive in the motor cortex of cases with rapid progression of disease. Conclusions This study demonstrates that microglial pathology in the CST of ALS correlates with disease progression and is linked to severity of UMN deficits. PMID:22720079

  13. Kinetics of bacterial fluorescence staining with 3,3'-diethylthiacyanine.

    PubMed

    Thomas, Marlon S; Nuñez, Vicente; Upadhyayula, Srigokul; Zielins, Elizabeth R; Bao, Duoduo; Vasquez, Jacob M; Bahmani, Baharak; Vullev, Valentine I

    2010-06-15

    For more than a century, colorimetric and fluorescence staining have been the foundation of a broad range of key bioanalytical techniques. The dynamics of such staining processes, however, still remains largely unexplored. We investigated the kinetics of fluorescence staining of two gram-negative and two gram-positive species with 3,3'-diethylthiacyanine (THIA) iodide. An increase in the THIA fluorescence quantum yield, induced by the bacterial dye uptake, was the principal reason for the observed emission enhancement. The fluorescence quantum yield of THIA depended on the media viscosity and not on the media polarity, which suggested that the microenvironment of the dye molecules taken up by the cells was restrictive. The kinetics of fluorescence staining did not manifest a statistically significant dependence neither on the dye concentration, nor on the cell count. In the presence of surfactant additives, however, the fluorescence-enhancement kinetic patterns manifested species specificity with statistically significant discernibility.

  14. Immunohistochemical staining of precursor forms of prostate-specific antigen (proPSA) in metastatic prostate cancer.

    PubMed

    Parwani, Anil V; Marlow, Cameron; Demarzo, Angelo M; Mikolajczyk, Stephen D; Rittenhouse, Harry G; Veltri, Robert W; Chan, Theresa Y

    2006-10-01

    Precursors of prostate-specific antigen (proPSA) have been previously shown to be more concentrated in prostate cancer tissue. This study characterizes the immunohistochemical staining (IHS) of proPSA forms in metastatic prostate cancer compared with prostate specific antigen (PSA) and prostatic acid phosphatase (PAP). A tissue microarray, consisting of 74 cases of metastatic prostate carcinoma and control tissues, was used. IHS, using monoclonal antibodies against proPSA with a truncated proleader peptide containing 2 amino acids ([-2]pPSA), native ([-5/-7]pPSA), PSA, and PAP, was analyzed. The monoclonal antibodies were specific for both benign and malignant prostatic glandular tissue. IHS with [-5/-7]pPSA showed the least number of cases with negative staining (3%), and the most number of cases with moderate or strong staining (76%). In the 60 cases where all 4 stains could be evaluated, none of them were negative for proPSA and positive for PSA or PAP, and all 7 cases that were negative for both PSA and PAP showed IHS to proPSA. [-5/-7]pPSA (native proPSA) may be a better marker than PSA and PAP in characterizing metastatic prostate adenocarcinoma, with most of the cases showing positivity for the marker. Even cases that were negative for PSA and PAP, were reactive for proPSA. Such enhanced detection is particularly important in poorly differentiated carcinomas involving metastatic sites where prostate carcinoma is a consideration. A panel of markers, including proPSA, should be performed when metastatic prostate carcinoma is in the differential diagnosis.

  15. p16/Ki-67 Dual Stain Cytology for Detection of Cervical Precancer in HPV-Positive Women.

    PubMed

    Wentzensen, Nicolas; Fetterman, Barbara; Castle, Philip E; Schiffman, Mark; Wood, Shannon N; Stiemerling, Eric; Tokugawa, Diane; Bodelon, Clara; Poitras, Nancy; Lorey, Thomas; Kinney, Walter

    2015-12-01

    Human papillomavirus (HPV)-based cervical cancer screening requires triage markers to decide who should be referred to colposcopy. p16/Ki-67 dual stain cytology has been proposed as a biomarker for cervical precancers. We evaluated the dual stain in a large population of HPV-positive women. One thousand five hundred and nine HPV-positive women screened with HPV/cytology cotesting at Kaiser Permanente California were enrolled into a prospective observational study in 2012. Dual stain cytology was performed on residual Surepath material, and slides were evaluated for dual stain-positive cells. Disease endpoints were ascertained from the clinical database at KPNC. We evaluated the clinical performance of the assay among all HPV-positive women and among HPV-positive, cytology-negative women. We used internal benchmarks for clinical management to evaluate the clinical relevance of the dual stain assay. We evaluated sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the dual stain compared with Pap cytology. All statistical tests were two-sided. The dual stain had lower positivity (45.9%) compared with cytology at an ASC-US threshold (53.4%). For detection of CIN2+, the dual stain had similar sensitivity (83.4% vs 76.6%, P = .1), and statistically higher specificity (58.9% vs 49.6%, P < .001), PPV (21.0% vs 16.6%, P < .001), and NPV (96.4% vs 94.2%, P = .01) compared with cytology. Similar patterns were observed for CIN3+. Women with a positive test had high enough risk for referral to colposcopy, while the risk for women with negative tests was below a one-year return threshold based on current US management guidelines. Dual stain cytology showed good risk stratification for all HPV-positive women and for HPV-positive women with normal cytology. Additional follow-up is needed to determine how long dual stain negative women remain at low risk of precancer. Published by Oxford University Press 2015. This work is written by (a

  16. A Comparison of Heat versus Methanol Fixation for Gram Staining Bacteria

    ERIC Educational Resources Information Center

    Minnerath, Jeanne M.; Roland, Jenna M.; Rossi, Lucas C.; Weishalla, Steven R.; Wolf, Melissa M.

    2009-01-01

    Gram staining bacteria is a fundamental technique introduced in general biology and microbiology laboratory courses. Two common problems students encounter when Gram staining bacteria are (1) having a difficult time locating bacterial cells on the microscope slide and (2) over-decolorizing bacterial cells during the staining procedure such that…

  17. Preparation of colloidal gold for staining proteins electrotransferred onto nitrocellulose membranes.

    PubMed

    Yamaguchi, K; Asakawa, H

    1988-07-01

    This paper describes a simple method of preparing colloidal gold for staining protein blots. Colloidal gold was prepared from 0.005 or 0.01% HAuCl4 by the addition of formalin as a reductant and potassium hydroxide. Staining of small cell carcinoma tissue extract blotted onto nitrocellulose membranes with this colloidal gold solution resulted in the appearance of a large number of clear wine-red bands. The sensitivity of gold staining was 60 times higher than that of Coomassie brilliant blue staining and almost comparable to that of silver staining of proteins in polyacrylamide gel. The sensitivity of this method was also satisfactory in comparison with that of enzyme immunoblotting. The colloidal gold prepared by this method is usable for routine work.

  18. Evaluation of Vitality in the Experimental Hanging Model of Rats by Using Immunohistochemical IL-1β Antibody Staining.

    PubMed

    Balandiz, Hüseyin; Pehlivan, Sultan; Çiçek, Ali Fuat; Tuğcu, Harun

    2015-12-01

    Hanging is the most common suicide method in the world, and the discrimination of antemortem-postmortem hanging must be done at autopsy. The aim of this experimental study was to examine the immunohistochemical expression of IL-1β antibody at the hanging mark skin samples of rats to discriminate antemortem and postmortem hangings. A total of 20 Wistar albino rats were used for this study. The groups were as follows: A-1, antemortem control group; A-2, antemortem second-hour hanging mark skin samples; A-3, antemortem 24th-hour hanging mark skin samples; A-4, antemortem 72nd-hour hanging mark skin samples; B-1, postmortem control group; and B-2, postmortem second-hour hanging mark skin samples. Interleukin-1β immunostaining was performed to all tissue samples. For epidermal cells, group A-1 samples did not show IL-1β immunostaining, group A-2 samples were severely immunostained, and groups A-3 and A-4 samples' staining were slightly decreased. There was no IL-1β antibody staining in groups B-1 and B-2 samples. For adnexal cells, groups A-1 and B-1 samples did not show IL-1β immunostaining, staining of group A-2 samples was mild to severe, and groups A-3 and A-4 samples' staining were slightly decreased. Half of the group B-2 samples did not show IL-1β immunostaining. For subepidermal cells, most of the samples of groups A-1 and B-1 showed slight immunostaining, groups A-2 and B-2 samples' staining were mild to severe, and there were slight immunostaining in groups A-3 and A-4 samples. The majority of vascular structure cells did not show IL-1β immunostaining. Interleukin-1β immunostaining of epidermal cells can discriminate antemortem-postmortem hangings, but vascular structure cells and subepidermal cells cannot discriminate vital hangings.

  19. α7-nAChR Knockout Mice Decreases Biliary Hyperplasia and Liver Fibrosis in Cholestatic Bile-Duct Ligated Mice.

    PubMed

    Ehrlich, Laurent; O'Brien, April; Hall, Chad; White, Tori; Chen, Lixian; Wu, Nan; Venter, Julie; Scrushy, Marinda; Mubarak, Muhammad; Meng, Fanyin; Dostal, David; Wu, Chaodong; Lairmore, Terry C; Alpini, Gianfranco; Glaser, Shannon

    2018-03-26

    α7-nAChR is a nicotinic acetylcholine receptor (specifically expressed on hepatic stellate cells, Kupffer cells, and cholangiocytes) that regulates inflammation and apoptosis in the liver. Thus, targeting α7-nAChR may be therapeutic in biliary diseases. Bile-duct ligation (BDL) was performed on wild-type (WT) and α7-nAChR-/- mice. We first evaluated the expression of α7-nAChR by immunohistochemistry (IHC) in liver sections. IHC was also performed to assess intrahepatic bile-duct mass (IBDM), and Sirius Red staining was performed to quantify the amount of collagen deposition. Immunofluorescence was performed to assess co-localization of α7-nAChR with bile ducts (co-stained with CK-19) and hepatic stellate cells (HSCs) (co-stained with desmin). The mRNA expression of α7-nAChR, Ki67/PCNA (proliferation), fibrosis genes (TGF-β1, Fibronectin-1, Col1α1, and α-SMA), and inflammatory markers (IL-6, IL-1β, and TNFα) was measured by real-time PCR. Biliary TGF-β1 and hepatic CD68 (Kupffer cell marker) expression was assessed using IHC. α7-nAChR immunoreactivity was observed in both bile ducts and HSCs and increased following BDL. α7-nAChR-/- BDL mice exhibited decreased: (i) bile duct mass, liver fibrosis, and inflammation; and (ii) immunoreactivity of TGF-1 as well as expression of fibrosis genes compared to WT BDL mice. α7-nAChR activation triggers biliary proliferation and liver fibrosis and may be a therapeutic target in managing extra-hepatic biliary obstruction.

  20. Clinical Utility of an Automated Instrument for Gram Staining Single Slides ▿

    PubMed Central

    Baron, Ellen Jo; Mix, Samantha; Moradi, Wais

    2010-01-01

    Gram stains of 87 different clinical samples were prepared by the laboratory's conventional methods (automated or manual) and by a new single-slide-type automated staining instrument, GG&B AGS-1000. Gram stains from either heat- or methanol-fixed slides stained with the new instrument were easy to interpret, and results were essentially the same as those from the methanol-fixed slides prepared as a part of the routine workflow. This instrument is well suited to a rapid-response laboratory where Gram stain requests are commonly received on a stat basis. PMID:20410348

  1. Sperm viability assessment in marine invertebrates by fluorescent staining and spectrofluorimetry: A promising tool for assessing marine pollution impact.

    PubMed

    Gallo, Alessandra; Boni, Raffaele; Tosti, Elisabetta

    2018-01-01

    The viability of spermatozoa is a crucial parameter to evaluate their quality that is an important issue in ecotoxicological studies. Here, a new method has been developed to rapidly determine the viability of spermatozoa in three marine invertebrates: the ascidian Ciona intestinalis, the sea urchin Paracentrotus lividus and the mollusc Mytilus galloprovincialis. This method employed the dual DNA fluorescent staining coupled with spectrofluorimetric analysis. The dual fluorescent staining used the SYBR-14 stained live spermatozoa and propidium iodide stained degenerated cells that had lost membrane integrity. Stain uptake was assessed by confocal microscopy and then the percentage of live and dead spermatozoa was quantified by spectrofluorimetric analysis. The microscopic examination revealed three populations of spermatozoa: living-SYBR-14 stained, dead-PI stained, and dying-doubly stained spermatozoa. The fluorescence emission peak values recorded in a spectrofluorimeter provide the portion of live and dead spermatozoa showing a significant negative correlation. The stain combination was further validated using known ratios of live and dead spermatozoa. The present study demonstrated that the dual DNA staining with SYBR-14 and propidium iodide was effective in assessing viability of spermatozoa in marine invertebrates and that spectrofluorimetric analysis can be successfully employed to evaluate the percentage of live and dead spermatozoa. The method develop herein is simple, accurate, rapid, sensitive, and cost-effective, so it could be a useful tool by which marine pollutants may be screened for spermiotoxicity. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Colour stainability of indirect CAD-CAM processed composites vs. conventionally laboratory processed composites after immersion in staining solutions.

    PubMed

    Arocha, Mariana A; Basilio, Juan; Llopis, Jaume; Di Bella, Enrico; Roig, Miguel; Ardu, Stefano; Mayoral, Juan R

    2014-07-01

    The aim of this study was to determine, by using a spectrophotometer device, the colour stainability of two indirect CAD/CAM processed composites in comparison with two conventionally laboratory-processed composites after being immersed 4 weeks in staining solutions such as coffee, black tea and red wine, using distilled water as control group. Two indirect CAD/CAM composites (Lava Ultimate and Paradigm MZ100) and two conventionally laboratory-processed composites (SR Adoro and Premise Indirect) of shade A2 were selected (160 disc samples). Colour stainability was measured after 4 weeks of immersion in three staining solutions (black tea, coffee, red wine) and distilled water. Specimen's colour was measured each week by means of a spectrophotometer (CIE L*a*b* system). Statistical analysis was carried out performing repeated ANOVA measurements and Tukey's HSD test to evaluate differences in ΔE00 measurements between groups; the interactions among composites, staining solutions and time duration were also evaluated. All materials showed significant discoloration (p<0.01) when compared to control group. The highest ΔE00 observed was with red wine, whereas black tea showed the lowest one. Indirect laboratory-processed resin composites showed the highest colour stability compared with CAD/CAM resin blocks. CAD/CAM processed composites immersed in staining solutions showed lower colour stability when compared to conventionally laboratory-processed resin composites. The demand for CAD/CAM restorations has been increasing; however, colour stainability for such material has been insufficiently studied. Moreover, this has not been performed comparing CAD/CAM processed composites versus laboratory-processed indirect composites by immersing in staining solutions for long immersion periods. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Microscopic quantification of bacterial invasion by a novel antibody-independent staining method.

    PubMed

    Agerer, Franziska; Waeckerle, Stephanie; Hauck, Christof R

    2004-10-01

    Microscopic discrimination between extracellular and invasive, intracellular bacteria is a valuable technique in microbiology and immunology. We describe a novel fluorescence staining protocol, called FITC-biotin-avidin (FBA) staining, which allows the differentiation between extracellular and intracellular bacteria and is independent of specific antibodies directed against the microorganisms. FBA staining of eukaryotic cells infected with Gram-negative bacteria of the genus Neisseria or the Gram-positive pathogen Staphylococcus aureus are employed to validate the novel technique. The quantitative evaluation of intracellular pathogens by the FBA staining protocol yields identical results compared to parallel samples stained with conventional, antibody-dependent methods. FBA staining eliminates the need for cell permeabilization resulting in robust and rapid detection of invasive microbes. Taken together, FBA staining provides a reliable and convenient alternative for the differential detection of intracellular and extracellular bacteria and should be a valuable technical tool for the quantitative analysis of the invasive properties of pathogenic bacteria and other microorganisms.

  4. Staining of Tissue Sections for Electron Microscopy with Heavy Metals

    PubMed Central

    Watson, Michael L.

    1958-01-01

    Descriptions of three heavy metal stains and methods of application to tissue sections for electron microscopy are presented. Lead hydroxide stains rather selectively two types of particles in liver: those associated with the endoplasmic reticulum and containing ribonucleic acid and other somewhat larger particles. Barium hydroxide emphasizes certain bodies within vesicles of the Golgi region of hepatic cells. Alkalized lead acetate is useful as a general stain, as are also lead and barium hydroxides. PMID:13610936

  5. Effects of spaceflight on hypothalamic peptide systems controlling pituitary growth hormone dynamics

    NASA Technical Reports Server (NTRS)

    Sawchenko, P. E.; Arias, C.; Krasnov, I.; Grindeland, R. E.; Vale, W.

    1992-01-01

    Possible effects of reduced gravity on central hypophysiotropic systems controlling growth hormone (GH) secretion were investigated in rats flown on Cosmos 1887 and 2044 biosatellites. Immunohistochemical (IHC)staining for the growth hormone-releasing factor (GRF), somatostatin (SS), and other hypothalamic hormones was performed on hypothalami obtained from rats. IHC analysis was complemented by quantitative in situ assessments of mRNAs encoding the precursors for these hormones. Data obtained suggest that exposure to microgravity causes a preferential reduction in GRF peptide and mRNA levels in hypophysiotropic neurons, which may contribute to impared GH secretion in animals subjected to spaceflight. Effects of weightlessness are not mimicked by hindlimb suspension in this system.

  6. Correlation of EGFR expression, gene copy number and clinicopathological status in NSCLC.

    PubMed

    Gaber, Rania; Watermann, Iris; Kugler, Christian; Reinmuth, Nils; Huber, Rudolf M; Schnabel, Philipp A; Vollmer, Ekkehard; Reck, Martin; Goldmann, Torsten

    2014-09-17

    Epidermal Growth Factor Receptor (EGFR) targeting therapies are currently of great relevance for the treatment of lung cancer. For this reason, in addition to mutational analysis immunohistochemistry (IHC) of EGFR in lung cancer has been discussed for the decision making of according therapeutic strategies. The aim of this study was to obtain standardization of EGFR-expression methods for the selection of patients who might benefit of EGFR targeting therapies. As a starting point of a broad investigation, aimed at elucidating the expression of EGFR on different biological levels, four EGFR specific antibodies were analyzed concerning potential differences in expression levels by Immunohistochemistry (IHC) and correlated with fluorescence in situ hybridization (FISH) analysis and clinicopathological data. 206 tumor tissues were analyzed in a tissue microarray format employing immunohistochemistry with four different antibodies including Dako PharmDx kit (clone 2-18C9), clone 31G7, clone 2.1E1 and clone SP84 using three different scoring methods. Protein expression was compared to FISH utilizing two different probes. EGFR protein expression determined by IHC with Dako PharmDx kit, clone 31G7 and clone 2.1E1 (p ≤ 0.05) correlated significantly with both FISH probes independently of the three scoring methods; best correlation is shown for 31G7 using the scoring method that defined EGFR positivity when ≥ 10% of the tumor cells show membranous staining of moderate and severe intensity (p=0.001). Overall, our data show differences in EGFR expression determined by IHC, due to the applied antibody. Highest concordance with FISH is shown for antibody clone 31G7, evaluated with score B (p=0.001). On this account, this antibody clone might by utilized for standard evaluation of EGFR expression by IHC. The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/13000_2014_165.

  7. Whole Blood Cell Staining Device

    NASA Technical Reports Server (NTRS)

    Sams, Clarence F.; Clift, Vaughan L.; McDonald, Kelly E.

    2000-01-01

    An apparatus and method for staining particular cell markers is disclosed. The apparatus includes a flexible tube that is reversibly pinched into compartments with one or more clamps. Each compartment of the tube contains a separate reagent and is in selective fluid communication with adjoining compartments.

  8. Evaluation of staining methods for cytologic diagnosis of oral lesions.

    PubMed

    Almeida, Janete Dias; Lima, Celina Faig; Brandão, Adriana Aigotti Haberbeck; Cabral, Luiz Antonio Guimarães

    2008-01-01

    To compare the efficacy ofPapanicolaou, hematoxylin-eosin (H-E), Leishman and periodic acid-Schiff (PAS) staining for cytologic diagnosis of oral lesions. Patients from the Discipline of Stomatology, São José dos Campos Dental School, from the wards of Hosapital Heliópolis and from the dentistry outpatient clinic of the University Hospital, University of São Paulo Medical School, with the following diseases, were selected: erythematous candidiasis (n=9), pseudomembranous candidiasis (n=10), squamous cell carcinoma (n=19), herpes simplex (n=8), paracoccidioidomycosis (n=8) and pemphigus vulgaris (n=1). The different staining methods were compared regarding the quality of definition of cytoplasmic and nuclear morphologic characteristics and the identification of bacteria, fungi, inflammatory cells and secretions. Papanicolaou and H-E staining were considered better methods. In cases of fungal infections, PAS staining is useful and should be applied as a complementary method. Within the limitations of this study, it can be concluded that the cytologic diagnosis of oral lesions along with different staining methods is a useful tool for oral diagnosis.

  9. Decreased mortality associated with prompt Gram staining of blood cultures.

    PubMed

    Barenfanger, Joan; Graham, Donald R; Kolluri, Lavanya; Sangwan, Gaurav; Lawhorn, Jerry; Drake, Cheryl A; Verhulst, Steven J; Peterson, Ryan; Moja, Lauren B; Ertmoed, Matthew M; Moja, Ashley B; Shevlin, Douglas W; Vautrain, Robert; Callahan, Charles D

    2008-12-01

    Gram stains of positive blood cultures are the most important factor influencing appropriate therapy. The sooner appropriate therapy is initiated, the better. Therefore, it is reasonable to expect that the sooner Gram stains are performed, the better. To determine the value of timely Gram stains and whether improvement in Gram stain turnaround time (TAT) is feasible, we compared data for matched pairs of patients with cultures processed promptly (<1 hour TAT) with data for patients with cultures not processed promptly (> or =1 hour TAT) and then monitored TAT by control charting.In 99 matched pairs, average difference in time to detection of positive blood cultures within a pair of patients was less than 0.1 hour. For the less than 1 hour TAT group, the average TAT and crude mortality were 0.1 hour and 10.1%, respectively; for the 1 hour or longer TAT group, they were 3.3 hours and 19.2%, respectively (P < .0001 and P = .0389, respectively). After multifaceted efforts, we achieved significant improvement in the TAT for Gram stains.

  10. Sclerostin as a potential novel biomarker for aortic valve calcification: an in-vivo and ex-vivo study.

    PubMed

    Koos, Ralf; Brandenburg, Vincent; Mahnken, Andreas Horst; Schneider, Rebekka; Dohmen, Guido; Autschbach, Rüdiger; Marx, Nikolaus; Kramann, Rafael

    2013-05-01

    Sclerostin is a key negative regulator of bone formation. It was hypothesized that sclerostin might also play a potential role in the development of aortic valve calcification (AVC). The study aim was to evaluate serum sclerostin levels in patients with different degrees of AVC compared to a healthy control group, and to investigate local sclerostin expression in explanted calcified and non-calcified aortic valves. A prospective cross-sectional study was performed in 115 patients (mean age 74 +/- 7 years) with echocardiographically proven AVC. Sclerostin serum levels were measured using ELISA and compared to values obtained from a healthy control population. For quantification of AVC, all patients of the study cohort underwent non-contrast-enhanced dual-source computed tomography (DSCT). Immunohistochemistry (IHC) staining for sclerostin and mRNA sclerostin expression was analyzed in 10 calcified aortic valves and 10 non-calcified age-matched control valves. Patients with AVC showed significantly higher sclerostin serum levels as compared to healthy controls (0.94 +/- 0.45 versus 0.58 +/- 0.26 ng/ml, p < 0.001). A significant correlation between sclerostin serum levels and Agatston AVC scores as assessed by DSCT was observed (r = 0.62, p < 0.001) in the study cohort. IHC revealed positive sclerostin staining in nine calcified valves, in contrast to negative staining for sclerostin in all non-calcified valves. Quantitative real-time PCR confirmed the increased sclerostin expression on mRNA level, with a significant up-regulation of sclerostin mRNA (fold change 150 +/- 52, p < 0.001) expression being shown in calcified aortic valves compared to non-calcified control valves. Co-staining experiments revealed that sclerostin-expressing cells co-express the major osteogenic transcription factor Runx2 and the extracellular matrix protein osteocalcin. Patients with AVC showed increased sclerostin serum levels compared to a healthy reference population, and it was revealed

  11. New staining methods for yeast like fungi under special consideration of human pathogenic fungi

    NASA Astrophysics Data System (ADS)

    Paulitsch-Fuchs, Astrid; Treiber, Fritz; Grasser, Erik; Buzina, Walter; Rosker, Christian

    2010-11-01

    A new method for in-cellular staining of yeast like fungi with Oregon Green and SYTOX Green is presented enabling their detection as well as the observation of cellular details via confocal laser scanning microscopy. Fluorochromes play an important role in many scientific disciplines including medicine, cell biology and botany. For the visualisation of fungal cell walls Calcofluor White is the flourochrome of choice. The necessity of an UV laser for its excitation makes it unpracticable for daily use. Safranin O, DAPI, 2NBDG, Ethidium Bromide and Acridin-orange are commonly used stains for nuclei in fugal microscopy. The attention was given to the possibility of using the differences in staining patterns to distinguish certain pathogenic yeast species e.g. Candida albicans and Candida krusei. Our results show that high quality microscopy of yeast like organisms can readily be achieved by the use of two suitable fluorochromes.

  12. Immunostaining with EGFR mutation-specific antibodies: a reliable screening method for lung adenocarcinomas harboring EGFR mutation in biopsy and resection samples.

    PubMed

    Fan, Xiangshan; Liu, Biao; Xu, Haodong; Yu, Bo; Shi, Shanshan; Zhang, Jin; Wang, Xuan; Wang, Jiandong; Lu, Zhenfeng; Ma, Henghui; Zhou, Xiaojun

    2013-08-01

    Mutation analysis of epidermal growth factor receptor (EGFR) is essential in determining the therapeutic strategy for lung adenocarcinoma. Immunohistochemical (IHC) staining with EGFR mutation-specific antibodies of del E746-A750 in exon 19 and L858R in exon 21 has been evaluated in resection specimens in a few studies but rarely in biopsy samples. A total of 169 cases (78 biopsies and 91 resected specimens) of lung adenocarcinoma with EGFR mutation status predefined by direct DNA sequencing were histologically examined, and IHC was performed using EGFR mutation-specific antibodies of del E746-A750 and L858R. The cases with positive results by IHC but negative results by direct DNA sequencing were examined by amplified refractory mutation system. Our results showed that the frequency of EGFR mutations for both E746-A750 deletion and L858R mutation was 38.5% (65/169) by DNA sequencing or amplified refractory mutation system and 34.3% (58/169) by IHC in lung adenocarcinomas. Based on molecular test results, the overall sensitivity, specificity, positive predictive value, and negative predictive value of IHC using these 2 antibodies in all (biopsy/resection) cases were 87.7% (80%/94.3%), 99.0% (97.9%/100%), 98.3% (96%/100%), and 92.8% (88.7%/96.6%), respectively. Lung adenocarcinomas with a predominant acinar, papillary, lepidic, or solid growth pattern more often harbor EGFR mutation of del E746-A750 or L858R. In conclusion, the immunostaining with EGFR del E746-A750 and L858R mutation antibodies is a reliable screening method with high specificity and sensitivity for identifying the EGFR mutation in both resected and biopsied lung adenocarcinomas. Copyright © 2013 Elsevier Inc. All rights reserved.

  13. Pathology reporting of malignant pleural mesothelioma first diagnosis: A population-based approach.

    PubMed

    Ascoli, Valeria; Minelli, Giada; Cozzi, Ilaria; Romeo, Elisa; Carnovale Scalzo, Caterina; Ancona, Laura; Forastiere, Francesco

    2016-10-01

    Accurate pathologic diagnosis and reporting in malignant pleural mesothelioma are essential for clinical care, and cancer registration. Practical guidelines for pathologists are provided in publications and textbooks but it is unclear how these recommendations are applied in routine practice. We investigated the characteristics of pathology reports, and the extent to which they meet guideline standards. We reviewed 819 pathology reports relating to a first diagnosis of malignant pleural mesothelioma. Data sources were a regional section of the Italian network of the Mesothelioma Registry (2001-2014) and a pathology archive (1990-2000). We evaluated tumor characteristics, the diagnosis field including terminology and immunohistochemistry (IHC) workup, and report completeness (the proportion of items recorded). We investigated also two IHC panels identified by the most used markers in current practical guidelines, one best suited for epithelioid mesotheliomas (combinations of at least 2 positive and at least 2 negative mesothelioma markers) and the other best suited for sarcomatoid mesotheliomas (positive mesothelioma markers plus cytokeratins). Reports (753 histology, 66 cytology, IHC-confirmed 86%) were 74% complete and always narrative. Missing data were related to clinical history (76%), tumor laterality (61%), specimen size (38%), and histological subtype (23%). The proportion of cases with IHC was higher for epithelioid (90%) than sarcomatoid mesothelioma (87%). Compliance to IHC recommendations was higher for epithelioid (59%) than sarcomatoid mesothelioma (11%). The mean number of stains was significantly higher for sarcomatoid than epithelioid mesothelioma (p<0.000; Kruskal-Wallis test). Our findings show that although guidelines are designed to improve actual reporting practices, there is ample room for improvement in their application to standardize the diagnosis of mesothelioma. Synoptic pathology reporting needs to be implemented to better utilize

  14. Prevalence and clinical outcomes for patients with ALK-positive resected stage I to III adenocarcinoma: results from the European Thoracic Oncology Platform Lungscape Project.

    PubMed

    Blackhall, Fiona H; Peters, Solange; Bubendorf, Lukas; Dafni, Urania; Kerr, Keith M; Hager, Henrik; Soltermann, Alex; O'Byrne, Kenneth J; Dooms, Christoph; Sejda, Aleksandra; Hernández-Losa, Javier; Marchetti, Antonio; Savic, Spasenija; Tan, Qiang; Thunnissen, Erik; Speel, Ernst-Jan M; Cheney, Richard; Nonaka, Daisuke; de Jong, Jeroen; Martorell, Miguel; Letovanec, Igor; Rosell, Rafael; Stahel, Rolf A

    2014-09-01

    The prevalence of anaplastic lymphoma kinase (ALK) gene fusion (ALK positivity) in early-stage non-small-cell lung cancer (NSCLC) varies by population examined and detection method used. The Lungscape ALK project was designed to address the prevalence and prognostic impact of ALK positivity in resected lung adenocarcinoma in a primarily European population. Analysis of ALK status was performed by immunohistochemistry (IHC) and fluorescent in situ hybridization (FISH) in tissue sections of 1,281 patients with adenocarcinoma in the European Thoracic Oncology Platform Lungscape iBiobank. Positive patients were matched with negative patients in a 1:2 ratio, both for IHC and for FISH testing. Testing was performed in 16 participating centers, using the same protocol after passing external quality assessment. Positive ALK IHC staining was present in 80 patients (prevalence of 6.2%; 95% CI, 4.9% to 7.6%). Of these, 28 patients were ALK FISH positive, corresponding to a lower bound for the prevalence of FISH positivity of 2.2%. FISH specificity was 100%, and FISH sensitivity was 35.0% (95% CI, 24.7% to 46.5%), with a sensitivity value of 81.3% (95% CI, 63.6% to 92.8%) for IHC 2+/3+ patients. The hazard of death for FISH-positive patients was lower than for IHC-negative patients (P = .022). Multivariable models, adjusted for patient, tumor, and treatment characteristics, and matched cohort analysis confirmed that ALK FISH positivity is a predictor for better overall survival (OS). In this large cohort of surgically resected lung adenocarcinomas, the prevalence of ALK positivity was 6.2% using IHC and at least 2.2% using FISH. A screening strategy based on IHC or H-score could be envisaged. ALK positivity (by either IHC or FISH) was related to better OS. © 2014 by American Society of Clinical Oncology.

  15. Preselection of EGFR mutations in non-small-cell lung cancer patients by immunohistochemistry: comparison with DNA-sequencing, EGFR wild-type expression, gene copy number gain and clinicopathological data.

    PubMed

    Gaber, Rania; Watermann, Iris; Kugler, Christian; Vollmer, Ekkehard; Perner, Sven; Reck, Martin; Goldmann, Torsten

    2017-01-01

    Targeting epidermal growth factor receptor (EGFR) in patients with non-small-cell lung cancer (NSCLC) having EGFR mutations is associated with an improved overall survival. The aim of this study is to verify, if EGFR mutations detected by immunohistochemistry (IHC) is a convincing way to preselect patients for DNA-sequencing and to figure out, the statistical association between EGFR mutation, wild-type EGFR overexpression, gene copy number gain, which are the main factors inducing EGFR tumorigenic activity and the clinicopathological data. Two hundred sixteen tumor tissue samples of primarily chemotherapeutic naïve NSCLC patients were analyzed for EGFR mutations E746-A750del and L858R and correlated with DNA-sequencing. Two hundred six of which were assessed by IHC, using 6B6 and 43B2 specific antibodies followed by DNA-sequencing of positive cases and 10 already genotyped tumor tissues were also included to investigate debugging accuracy of IHC. In addition, EGFR wild-type overexpression was IHC evaluated and EGFR gene copy number determination was performed by fluorescence in situ hybridization (FISH). Forty-one÷206 (19.9%) cases were positive for mutated EGFR by IHC. Eight of them had EGFR mutations of exons 18-21 by DNA-sequencing. Hit rate of 10 already genotyped NSCLC mutated cases was 90% by IHC. Positive association was found between EGFR mutations determined by IHC and both EGFR overexpression and increased gene copy number (p=0.002 and p<0.001, respectively). Additionally, positive association was detected between EGFR mutations, high tumor grade and clinical stage (p<0.001). IHC staining with mutation specific antibodies was demonstrated as a possible useful screening test to preselect patients for DNA-sequencing.

  16. TGF-β1 related inflammation in the posterior longitudinal ligament of cervical spondylotic myelopathy patients.

    PubMed

    Wang, Jia-Zeng; Fang, Xiu-Tong; Lv, E; Yu, Fang; Wang, Zhen-Wei; Song, Hong-Xing

    2015-01-01

    This study aimed to elucidate the pathogenesis of posterior longitudinal ligament (PLL) hypertrophy. Cervical PLL specimens were collected from CSM patients during surgery (n = 30) and during routine autopsy (n = 14), and processed for histological examination (HE staining and Masson's Trichrome staining) and IHC (CD3, CD68, CD31, TGF-β1 and collagen II). In addition, the mRNA expression of collagen I was detected in cervical PLL specimens from 16 CSM patients (n = 16) and from routine autopsy (n = 16) by RT-PCR. Obvious fibrosis, cartilage metaplasia and calcification were found in the cervical PLL of CSM patients. In the degenerated PLL, CD68(+) macrophages were frequently identified, CD3(+) T lymphocytes were occasionally found, and many newly generated small vessels were also present. In the degenerated PLL, of the number of TGF-β1 positive cells increased markedly when compared with control group. IHC indicated TGF-β1 was secreted by macrophages. RT-PCR showed a significantly lower mRNA expression of collagen I in the PLL of CSM patients as compared to control group. Macrophages are the major type of inflammatory cells involved in the cervical PLL degeneration, and TGF-β1 is related to the cervical PLL degeneration. TGF-β1 is mainly secreted by macrophages. Anti-inflammation may serve as an alternative non-surgical treatment and prophylactic strategy for PLL degeneration.

  17. Human breast cancer histoid: an in vitro 3-dimensional co-culture model that mimics breast cancer tissue.

    PubMed

    Kaur, Pavinder; Ward, Brenda; Saha, Baisakhi; Young, Lillian; Groshen, Susan; Techy, Geza; Lu, Yani; Atkinson, Roscoe; Taylor, Clive R; Ingram, Marylou; Imam, S Ashraf

    2011-12-01

    Progress in our understanding of heterotypic cellular interaction in the tumor microenvironment, which is recognized to play major roles in cancer progression, has been hampered due to unavailability of an appropriate in vitro co-culture model. The aim of this study was to generate an in vitro 3-dimensional human breast cancer model, which consists of cancer cells and fibroblasts. Breast cancer cells (UACC-893) and fibroblasts at various densities were co-cultured in a rotating suspension culture system to establish co-culture parameters. Subsequently, UACC-893, BT.20, or MDA.MB.453 were co-cultured with fibroblasts for 9 days. Co-cultures resulted in the generation of breast cancer histoid (BCH) with cancer cells showing the invasion of fibroblast spheroids, which were visualized by immunohistochemical (IHC) staining of sections (4 µm thick) of BCH. A reproducible quantitative expression of C-erbB.2 was detected in UACC-893 cancer cells in BCH sections by IHC staining and the Automated Cellular Imaging System. BCH sections also consistently exhibited qualitative expression of pancytokeratins, p53, Ki-67, or E-cadherin in cancer cells and that of vimentin or GSTPi in fibroblasts, fibronectin in the basement membrane and collagen IV in the extracellular matrix. The expression of the protein analytes and cellular architecture of BCH were markedly similar to those of breast cancer tissue.

  18. Human Breast Cancer Histoid

    PubMed Central

    Kaur, Pavinder; Ward, Brenda; Saha, Baisakhi; Young, Lillian; Groshen, Susan; Techy, Geza; Lu, Yani; Atkinson, Roscoe; Taylor, Clive R.; Ingram, Marylou

    2011-01-01

    Progress in our understanding of heterotypic cellular interaction in the tumor microenvironment, which is recognized to play major roles in cancer progression, has been hampered due to unavailability of an appropriate in vitro co-culture model. The aim of this study was to generate an in vitro 3-dimensional human breast cancer model, which consists of cancer cells and fibroblasts. Breast cancer cells (UACC-893) and fibroblasts at various densities were co-cultured in a rotating suspension culture system to establish co-culture parameters. Subsequently, UACC-893, BT.20, or MDA.MB.453 were co-cultured with fibroblasts for 9 days. Co-cultures resulted in the generation of breast cancer histoid (BCH) with cancer cells showing the invasion of fibroblast spheroids, which were visualized by immunohistochemical (IHC) staining of sections (4 µm thick) of BCH. A reproducible quantitative expression of C-erbB.2 was detected in UACC-893 cancer cells in BCH sections by IHC staining and the Automated Cellular Imaging System. BCH sections also consistently exhibited qualitative expression of pancytokeratins, p53, Ki-67, or E-cadherin in cancer cells and that of vimentin or GSTPi in fibroblasts, fibronectin in the basement membrane and collagen IV in the extracellular matrix. The expression of the protein analytes and cellular architecture of BCH were markedly similar to those of breast cancer tissue. PMID:22034518

  19. Impact of round-the-clock CSF Gram stain on empirical therapy for suspected central nervous system infections.

    PubMed

    Tissot, F; Prod'hom, G; Manuel, O; Greub, G

    2015-09-01

    The impact of round-the-clock cerebrospinal fluid (CSF) Gram stain on overnight empirical therapy for suspected central nervous system (CNS) infections was investigated. All consecutive overnight CSF Gram stains between 2006 and 2011 were included. The impact of a positive or a negative test on empirical therapy was evaluated and compared to other clinical and biological indications based on institutional guidelines. Bacterial CNS infection was documented in 51/241 suspected cases. Overnight CSF Gram stain was positive in 24/51. Upon validation, there were two false-positive and one false-negative results. The sensitivity and specificity were 41 and 99 %, respectively. All patients but one had other indications for empirical therapy than Gram stain alone. Upon obtaining the Gram result, empirical therapy was modified in 7/24, including the addition of an appropriate agent (1), addition of unnecessary agents (3) and simplification of unnecessary combination therapy (3/11). Among 74 cases with a negative CSF Gram stain and without formal indication for empirical therapy, antibiotics were withheld in only 29. Round-the-clock CSF Gram stain had a low impact on overnight empirical therapy for suspected CNS infections and was associated with several misinterpretation errors. Clinicians showed little confidence in CSF direct examination for simplifying or withholding therapy before definite microbiological results.

  20. Influence of intra-tumoral heterogeneity on the evaluation of BCL2, E-cadherin, EGFR, EMMPRIN, and Ki-67 expression in tissue microarrays from breast cancer.

    PubMed

    Tramm, Trine; Kyndi, Marianne; Sørensen, Flemming B; Overgaard, Jens; Alsner, Jan

    2018-01-01

    The influence of intra-tumoral heterogeneity on the evaluation of immunohistochemical (IHC) biomarker expression may affect the analytical validity of new biomarkers substantially and hence compromise the clinical utility. The aim of this study was to examine the influence of intra-tumoral heterogeneity as well as inter-observer variability on the evaluation of various IHC markers with potential prognostic impact in breast cancer (BCL2, E-cadherin, EGFR, EMMPRIN and Ki-67). From each of 27 breast cancer patients, two tumor-containing paraffin blocks were chosen. Intra-tumoral heterogeneity was evaluated (1) within a single tumor-containing paraffin block ('intra-block agreement') by comparing information from a central, a peripheral tissue microarray (TMA) core and a whole slide section (WS), (2) between two different tumor-containing blocks from the same primary tumor ('inter-block agreement') by comparing information from TMA cores (central/peripheral) and WS. IHC markers on WS and TMA cores were evaluated by two observers independently, and agreements were estimated by Kappa statistics. For BCL2, E-cadherin and EGFR, an almost perfect intra- and inter-block agreement was found. EMMPRIN and Ki-67 showed a more heterogeneous expression with moderate to substantial intra-block agreements. For both stainings, there was a moderate inter-block agreement that improved slightly for EMMPRIN, when using WS instead of TMA cores. Inter-observer agreements were found to be almost perfect for BCL2, E-cadherin and EGFR (WS: κ > 0.82, TMAs: κ > 0.90), substantial for EMMPRIN (κ > 0.63), but only fair to moderate for Ki-67 (WS: κ = 0.54, TMAs: κ = 0.33). BCL2, E-cadherin and EGFR were found to be homogeneously expressed, whereas EMMPRIN and Ki-67 showed a more pronounced degree of intra-tumoral heterogeneity. The results emphasize the importance of securing the analytical validity of new biomarkers by examining the intra-tumoral heterogeneity of

  1. Comparison of effectiveness of abrasive and enzymatic action of whitening toothpastes in removal of extrinsic stains - a clinical trial.

    PubMed

    Patil, P A; Ankola, A V; Hebbal, M I; Patil, A C

    2015-02-01

    To compare the effectiveness of abrasive component (perlite/calcium carbonate) and enzymatic component (papain and bromelain) of whitening toothpaste in removal of extrinsic stains. This study is a randomized, triple blind and parallel group study in which 90 subjects aged 18-40 years were included. At baseline, stains scores were assessed by Macpherson's modification of Lobene Stain Index and subjects were randomly assigned to two groups with 45 subjects in each. Group 1 used whitening toothpaste with enzymatic action and group 2 with abrasive action. After 1 month, stain scores were assessed for the effectiveness of the two toothpastes and 2 months later to check the stain prevention efficacy. Wilcoxson's test was used to compare between baseline 1 and 2 months stain scores, and Mann-Witney U-test was applied for intragroup comparison. The mean baseline total stain score for the subjects allocated to the enzymatic toothpaste was 37.24 ± 2.11 which reduced to 30.77 ± 2.48 in 1 month, and for the abrasive paste, total stain reduced from 35.08 ± 2.96 to 32.89 ± 1.95. The reductions in total stain scores with both the pastes were significant compared with baseline stain scores (at 1 month Group 1, P = 0.0233 and Group 2, P = 0.0324; at 2 months, Group 1 P = 0.0356). Both the toothpastes proved to be equally good in removal of extrinsic stains; however, the enzymatic paste showed better results as compared to abrasive toothpaste. Whitening toothpaste with abrasive action and enzymatic action are equally effective in removal of extrinsic stains; however, whitening toothpaste with abrasive action needs to be used with caution. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Computerized microscopic image analysis of follicular lymphoma

    NASA Astrophysics Data System (ADS)

    Sertel, Olcay; Kong, Jun; Lozanski, Gerard; Catalyurek, Umit; Saltz, Joel H.; Gurcan, Metin N.

    2008-03-01

    Follicular Lymphoma (FL) is a cancer arising from the lymphatic system. Originating from follicle center B cells, FL is mainly comprised of centrocytes (usually middle-to-small sized cells) and centroblasts (relatively large malignant cells). According to the World Health Organization's recommendations, there are three histological grades of FL characterized by the number of centroblasts per high-power field (hpf) of area 0.159 mm2. In current practice, these cells are manually counted from ten representative fields of follicles after visual examination of hematoxylin and eosin (H&E) stained slides by pathologists. Several studies clearly demonstrate the poor reproducibility of this grading system with very low inter-reader agreement. In this study, we are developing a computerized system to assist pathologists with this process. A hybrid approach that combines information from several slides with different stains has been developed. Thus, follicles are first detected from digitized microscopy images with immunohistochemistry (IHC) stains, (i.e., CD10 and CD20). The average sensitivity and specificity of the follicle detection tested on 30 images at 2×, 4× and 8× magnifications are 85.5+/-9.8% and 92.5+/-4.0%, respectively. Since the centroblasts detection is carried out in the H&E-stained slides, the follicles in the IHC-stained images are mapped to H&E-stained counterparts. To evaluate the centroblast differentiation capabilities of the system, 11 hpf images have been marked by an experienced pathologist who identified 41 centroblast cells and 53 non-centroblast cells. A non-supervised clustering process differentiates the centroblast cells from noncentroblast cells, resulting in 92.68% sensitivity and 90.57% specificity.

  3. Digital enhancement of haematoxylin- and eosin-stained histological images for red-green colour-blind observers.

    PubMed

    Landini, G; Perryer, G

    2009-06-01

    Individuals with red-green colour-blindness (CB) commonly experience great difficulty differentiating between certain histological stain pairs, notably haematoxylin-eosin (H&E). The prevalence of red-green CB is high (6-10% of males), including among medical and laboratory personnel, and raises two major concerns: first, accessibility and equity issues during the education and training of individuals with this disability, and second, the likelihood of errors in critical tasks such as interpreting histological images. Here we show two methods to enhance images of H&E-stained samples so the differently stained tissues can be well discriminated by red-green CBs while remaining usable by people with normal vision. Method 1 involves rotating and stretching the range of H&E hues in the image to span the perceptual range of the CB observers. Method 2 digitally unmixes the original dyes using colour deconvolution into two separate images and repositions the information into hues that are more distinctly perceived. The benefits of these methods were tested in 36 volunteers with normal vision and 11 with red-green CB using a variety of H&E stained tissue sections paired with their enhanced versions. CB subjects reported they could better perceive the different stains using the enhanced images for 85% of preparations (method 1: 90%, method 2: 73%), compared to the H&E-stained original images. Many subjects with normal vision also preferred the enhanced images to the original H&E. The results suggest that these colour manipulations confer considerable advantage for those with red-green colour vision deficiency while not disadvantaging people with normal colour vision.

  4. p16/Ki-67 Dual Stain Cytology for Detection of Cervical Precancer in HPV-Positive Women

    PubMed Central

    Fetterman, Barbara; Castle, Philip E.; Schiffman, Mark; Wood, Shannon N.; Stiemerling, Eric; Tokugawa, Diane; Bodelon, Clara; Poitras, Nancy; Lorey, Thomas; Kinney, Walter

    2015-01-01

    Background: Human papillomavirus (HPV)–based cervical cancer screening requires triage markers to decide who should be referred to colposcopy. p16/Ki-67 dual stain cytology has been proposed as a biomarker for cervical precancers. We evaluated the dual stain in a large population of HPV-positive women. Methods: One thousand five hundred and nine HPV-positive women screened with HPV/cytology cotesting at Kaiser Permanente California were enrolled into a prospective observational study in 2012. Dual stain cytology was performed on residual Surepath material, and slides were evaluated for dual stain–positive cells. Disease endpoints were ascertained from the clinical database at KPNC. We evaluated the clinical performance of the assay among all HPV-positive women and among HPV-positive, cytology-negative women. We used internal benchmarks for clinical management to evaluate the clinical relevance of the dual stain assay. We evaluated sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the dual stain compared with Pap cytology. All statistical tests were two-sided. Results: The dual stain had lower positivity (45.9%) compared with cytology at an ASC-US threshold (53.4%). For detection of CIN2+, the dual stain had similar sensitivity (83.4% vs 76.6%, P = .1), and statistically higher specificity (58.9% vs 49.6%, P < .001), PPV (21.0% vs 16.6%, P < .001), and NPV (96.4% vs 94.2%, P = .01) compared with cytology. Similar patterns were observed for CIN3+. Women with a positive test had high enough risk for referral to colposcopy, while the risk for women with negative tests was below a one-year return threshold based on current US management guidelines. Conclusion: Dual stain cytology showed good risk stratification for all HPV-positive women and for HPV-positive women with normal cytology. Additional follow-up is needed to determine how long dual stain negative women remain at low risk of precancer. PMID:26376685

  5. Usefulness of Leifson Staining Method in Diagnosis of Helicobacter pylori Infection

    PubMed Central

    Piccolomini, Raffaele; Di Bonaventura, Giovanni; Neri, Matteo; Di Girolamo, Arturo; Catamo, Giovanni; Pizzigallo, Eligio

    1999-01-01

    The Leifson staining method was used to diagnose Helicobacter pylori infection and was compared to histology, culture, and the rapid urease test (RUT). Histology gave the best sensitivity (98%), compared to Leifson staining (97%), culture (92%), and RUT (85%) (P < 0.005). Leifson staining is a sensitive, rapid, economical method for diagnosis of H. pylori infection in dyspeptic patients. PMID:9854090

  6. Improved Nissl method to stain formaldehyde or glutaraldehyde-fixed material.

    PubMed

    Böck, P

    1979-05-15

    Nissl staining of paraffin sections from formaldehyde- or glutaraldehyde-fixed specimens is significantly intensified when sections are kept in a 50% (w/v) aqueous solution of potassium metabisulfite before being stained by a conventional Nissl method.

  7. Length of stain dosimeter

    NASA Astrophysics Data System (ADS)

    Lueck, Dale E.

    1994-04-01

    Payload customers for the Space Shuttle have recently expressed concerns about the possibility of their payloads at an adjacent pad being contaminated by plume effluents from a shuttle at an active pad as they await launch on an inactive pad. As part of a study to satisfy such concerns a ring of inexpensive dosimeters was deployed around the active pad at the inter-pad distance. However, following a launch, dosimeters cannot be read for several hours after the exposure. As a consequence factors such as different substrates, solvent systems, and possible volatilization of HCl from the badges were studied. This observation led to the length of stain (LOS) dosimeters of this invention. Commercial passive LOS dosimeters are sensitive only to the extent of being capable of sensing 2 ppm to 20 ppm if the exposure is 8 hours. To map and quantitate the HCl generated by Shuttle launches, and in the atmosphere within a radius of 1.5 miles from the active pad, a sensitivity of 2 ppm HCl in the atmospheric gases on an exposure of 5 minutes is required. A passive length of stain dosimeter has been developed having a sensitivity rendering it capable of detecting a gas in a concentration as low as 2 ppm on an exposure of five minutes.

  8. Length of stain dosimeter

    NASA Technical Reports Server (NTRS)

    Lueck, Dale E. (Inventor)

    1994-01-01

    Payload customers for the Space Shuttle have recently expressed concerns about the possibility of their payloads at an adjacent pad being contaminated by plume effluents from a shuttle at an active pad as they await launch on an inactive pad. As part of a study to satisfy such concerns a ring of inexpensive dosimeters was deployed around the active pad at the inter-pad distance. However, following a launch, dosimeters cannot be read for several hours after the exposure. As a consequence factors such as different substrates, solvent systems, and possible volatilization of HCl from the badges were studied. This observation led to the length of stain (LOS) dosimeters of this invention. Commercial passive LOS dosimeters are sensitive only to the extent of being capable of sensing 2 ppm to 20 ppm if the exposure is 8 hours. To map and quantitate the HCl generated by Shuttle launches, and in the atmosphere within a radius of 1.5 miles from the active pad, a sensitivity of 2 ppm HCl in the atmospheric gases on an exposure of 5 minutes is required. A passive length of stain dosimeter has been developed having a sensitivity rendering it capable of detecting a gas in a concentration as low as 2 ppm on an exposure of five minutes.

  9. Discrepancies between descriptions and illustrations of colours in Congo red-stained amyloid, and explanation of discrepant colours.

    PubMed

    Howie, Alexander J; Owen-Casey, Mared P

    2010-09-01

    Congo red-stained sections of amyloid may show various colours between crossed polariser and analyser. The aims were to see how papers described the colours, to compare descriptions with illustrations, and to explain the colours. In 160 papers on Congo red-stained amyloid, the commonest descriptions were 'green birefringence' and 'apple-green birefringence'. In 191 figures in 82 papers, 59 (31%) showed a pure green colour, 62 (32%) showed green and yellow or blue and yellow, 38 (20%) showed green and a colour other than yellow, mostly red, and 32 (17%) showed other colours. Discrepancies between colours reported and illustrated were noted in 127 figures (66%). Most (77) were between green alone in descriptions and green and another colour in figures, and 30 were between green in descriptions and no green at all in figures. Pure green can be seen in ideal conditions, but more often there are green and yellow, explained by strain birefringence, and green and red or other combinations, explained by uncrossing of polariser and analyser. These other anomalous colours are just as characteristic of amyloid as the pure green colour. Many papers on Congo red-stained amyloid appear to describe what is expected theoretically rather than what is actually seen.

  10. Gram's Stain Does Not Cross the Bacterial Cytoplasmic Membrane.

    PubMed

    Wilhelm, Michael J; Sheffield, Joel B; Sharifian Gh, Mohammad; Wu, Yajing; Spahr, Christian; Gonella, Grazia; Xu, Bolei; Dai, Hai-Lung

    2015-07-17

    For well over a century, Hans Christian Gram's famous staining protocol has been the standard go-to diagnostic for characterizing unknown bacteria. Despite continuous and ubiquitous use, we now demonstrate that the current understanding of the molecular mechanism for this differential stain is largely incorrect. Using the fully complementary time-resolved methods: second-harmonic light-scattering and bright-field transmission microscopy, we present a real-time and membrane specific quantitative characterization of the bacterial uptake of crystal-violet (CV), the dye used in Gram's protocol. Our observations contradict the currently accepted mechanism which depicts that, for both Gram-negative and Gram-positive bacteria, CV readily traverses the peptidoglycan mesh (PM) and cytoplasmic membrane (CM) before equilibrating within the cytosol. We find that not only is CV unable to traverse the CM but, on the time-scale of the Gram-stain procedure, CV is kinetically trapped within the PM. Our results indicate that CV, rather than dyes which rapidly traverse the PM, is uniquely suited as the Gram stain.

  11. Strong FGFR3 staining is a marker for FGFR3 fusions in diffuse gliomas

    PubMed Central

    Annala, Matti; Lehtinen, Birgitta; Kesseli, Juha; Haapasalo, Joonas; Ruusuvuori, Pekka; Yli-Harja, Olli; Visakorpi, Tapio; Haapasalo, Hannu; Nykter, Matti; Zhang, Wei

    2017-01-01

    Abstract Background Inhibitors of fibroblast growth factor receptors (FGFRs) have recently arisen as a promising treatment option for patients with FGFR alterations. Gene fusions involving FGFR3 and transforming acidic coiled-coil protein 3 (TACC3) have been detected in diffuse gliomas and other malignancies, and fusion-positive cases have responded well to FGFR inhibition. As high FGFR3 expression has been detected in fusion-positive tumors, we sought to determine the clinical significance of FGFR3 protein expression level as well as its potential for indicating FGFR3 fusions. Methods We performed FGFR3 immunohistochemistry on tissue microarrays containing 676 grades II–IV astrocytomas and 116 grades II–III oligodendroglial tumor specimens. Fifty-one cases were further analyzed using targeted sequencing. Results Moderate to strong FGFR3 staining was detected in gliomas of all grades, was more common in females, and was associated with poor survival in diffuse astrocytomas. Targeted sequencing identified FGFR3-TACC3 fusions and an FGFR3-CAMK2A fusion in 10 of 15 strongly stained cases, whereas no fusions were found in 36 negatively to moderately stained cases. Fusion-positive cases were predominantly female and negative for IDH and EGFR/PDGFRA/MET alterations. These and moderately stained cases show lower MIB-1 proliferation index than negatively to weakly stained cases. Furthermore, stronger FGFR3 expression was commonly observed in malignant tissue regions of lower cellularity in fusion-negative cases. Importantly, subregional negative FGFR3 staining was also observed in a few fusion-positive cases. Conclusions Strong FGFR3 protein expression is indicative of FGFR3 fusions and may serve as a clinically applicable predictive marker for treatment regimens based on FGFR inhibitors. PMID:28379477

  12. Comparison of Gram and Kopeloff stains in the diagnosis of bacterial vaginosis in pregnancy.

    PubMed

    Libman, Michael D; Kramer, Michael; Platt, Robert

    2006-03-01

    Bacterial vaginosis (BV) is commonly diagnosed by using the Nugent score, a semiquantitative scoring system to evaluate bacterial morphotypes on Gram stain of vaginal secretions. Some authors have suggested using the Kopeloff modification of the Gram stain. Asymptomatic BV in pregnancy has been associated with adverse outcomes. We performed both stains on simultaneously collected vaginal smears from 2652 women at 24-26 weeks of gestation. Gram staining gave significantly higher (more abnormal) Nugent scores than Kopeloff staining. Compared to the Kopeloff stain, the number of specimens graded as indeterminate or consistent with BV by Gram stain increased by 29% (469 versus 364, P<.001). Interrater reliability of the Nugent score (n=413) for Kopeloff staining was significantly better than Gram staining (agreement=74% versus 63%, intraclass correlation coefficient=0.87 versus 0.79, P<.05, 95% confidence intervals 0.85-0.89 and 0.75-0.82, respectively).

  13. Histological staining can enhance the performance of spectroscopic microscopy on sensing nanoarchitectural alterations of biological cells (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Zhang, Di; Cherkezyan, Lusik; Li, Yue; Capoglu, Ilker; Subramanian, Hariharan; Taflove, Allen; Backman, Vadim

    2017-02-01

    Our group had previously established that nanoscale three-dimensional refractive index (RI) fluctuations of a linear, dielectric, label-free medium can be sensed in the far field through spectroscopic microscopy, regardless of the diffraction limit of optical microscopy. Adopting this technique, Partial Wave Spectroscopic (PWS) Microscopy was able to sense nanoarchitectural alterations in early-stage cancers. With the success of PWS on detecting cancer from healthy clinical samples, we further investigated whether and how histological staining can enhance the performance of PWS by both finite difference time domain (FDTD) simulations and experiments. In this investigation, the dispersion models of hematoxylin and eosin were extracted from the absorption spectra of H and E stained cells. Using these models, the effect of staining were studied via FDTD simulations of unstained versus stained samples with various nanostructures. We observed that, the spectral variance was increased and the spectral variance difference between two samples with distinct nanostructures was enhanced in stained samples by over 200%. Furthermore, we investigated with FDTD whether molecule-specific staining can be used to enhance signals from a medium composing of the desired molecule. Samples with two mixed random media were created and the desired medium was either stained or unstained. Our results showed that the difference between the nanostructures of only the desired medium was enhanced in stained samples. We concluded that, with molecule-specific staining, PWS can selectively target the nanoarchitecture of a desired molecule. Lastly, these results were validated by experiments using human buccal cells from healthy or lung cancer patients. This study has significant impact in improving the performance of PWS on quantifying nanoarchitectural alterations during cancer.

  14. A rapid method combining Golgi and Nissl staining to study neuronal morphology and cytoarchitecture.

    PubMed

    Pilati, Nadia; Barker, Matthew; Panteleimonitis, Sofoklis; Donga, Revers; Hamann, Martine

    2008-06-01

    The Golgi silver impregnation technique gives detailed information on neuronal morphology of the few neurons it labels, whereas the majority remain unstained. In contrast, the Nissl staining technique allows for consistent labeling of the whole neuronal population but gives very limited information on neuronal morphology. Most studies characterizing neuronal cell types in the context of their distribution within the tissue slice tend to use the Golgi silver impregnation technique for neuronal morphology followed by deimpregnation as a prerequisite for showing that neuron's histological location by subsequent Nissl staining. Here, we describe a rapid method combining Golgi silver impregnation with cresyl violet staining that provides a useful and simple approach to combining cellular morphology with cytoarchitecture without the need for deimpregnating the tissue. Our method allowed us to identify neurons of the facial nucleus and the supratrigeminal nucleus, as well as assessing cellular distribution within layers of the dorsal cochlear nucleus. With this method, we also have been able to directly compare morphological characteristics of neuronal somata at the dorsal cochlear nucleus when labeled with cresyl violet with those obtained with the Golgi method, and we found that cresyl violet-labeled cell bodies appear smaller at high cellular densities. Our observation suggests that cresyl violet staining is inadequate to quantify differences in soma sizes.

  15. Laser therapy in plastic surgery: decolorization in port wine stains

    NASA Astrophysics Data System (ADS)

    Peszynski-Drews, Cezary; Wolf, Leszek

    1996-03-01

    For the first time laserotherapy is described as a method of port wine stain decolorization in plastic surgery. The authors present their 20-year experience in the treatment of port wine stains with the argon laser and dye laser.

  16. Negative Staining for COL4A5 Correlates With Worse Prognosis and More Severe Ultrastructural Alterations in Males With Alport Syndrome.

    PubMed

    Said, Samar M; Fidler, Mary E; Valeri, Anthony M; McCann, Brooke; Fiedler, Wade; Cornell, Lynn D; Alexander, Mariam Priya; Alkhunaizi, Ahmed M; Sullivan, Anne; Cramer, Carl H; Hogan, Marie C; Nasr, Samih H

    2017-01-01

    Alport syndrome (AS) is a genetic disorder characterized by progressive hematuric nephropathy with or without sensorineural hearing loss and ocular lesions. Previous studies on AS included mostly children. To determine the prognostic value of loss of staining for collagen type IV alpha 5 (COL4A5) and its relationship with the ultrastructural glomerular basement membrane alterations, we performed direct immunofluorescence using a mixture of fluorescein isothiocyanate-conjugated and Texas-red conjugated antibodies against COL4A5 and COL4A2, respectively, on renal biopsies of 25 males with AS (including 16 who were diagnosed in adulthood). All patients showed normal positive staining of glomerular basement membranes and tubular basement membranes for COL4A2. Of the 25 patients, 10 (40%) patients showed loss of staining for COL4A5 (including 89% of children and 13% of adults) and the remaining 15 (60%) had intact staining for COL4A5. Compared with patients with intact staining for COL4A5, those with loss of staining had more prominent ultrastructural glomerular basement membrane alterations and were younger at the time of biopsy. By Kaplan-Meier survival analysis and Cox regression analysis, loss of staining for COL4A5 predicted earlier progression to overt proteinuria and stage 2 chronic kidney disease or worse. By multivariate Cox regression analysis, loss of staining for COL4A5 was an independent predictor of the development of overt proteinuria and stage 2 chronic kidney disease or worse. Thus, the COL4A5 expression pattern has an important prognostic value and it correlates with the severity of ultrastructural glomerular basement membrane alterations in males with AS. Loss of COL4A5 staining is uncommon in patients with AS diagnosed in their adulthood.

  17. CD30 Expression by B and T Cells: A Frequent Finding in Angioimmunoblastic T-Cell Lymphoma and Peripheral T-Cell Lymphoma-Not Otherwise Specified.

    PubMed

    Onaindia, Arantza; Martínez, Nerea; Montes-Moreno, Santiago; Almaraz, Carmen; Rodríguez-Pinilla, Socorro M; Cereceda, Laura; Revert, Jose B; Ortega, César; Tardio, Antoni; González, Lucía; García, Sonia; Camacho, Francisca I; González-Vela, Carmen; Piris, Miguel A

    2016-03-01

    CD30 expression in peripheral T-cell lymphoma (PTCL) and angioimmunoblastic T-cell lymphoma (AITL) is currently of great interest because therapy targeting CD30 is of clinical benefit, but the clinical and therapeutic relevance of CD30 expression in these neoplasms still remains uncertain. The aim of this study was to better quantify CD30 expression in AITL and PTCL-not otherwise specified (NOS). The secondary objective was to determine whether CD30 cells exhibit a B-cell or a T-cell phenotype. Gene expression profiling was studied in a series of 37 PTCL cases demonstrating a continuous spectrum of TNFRSF8 expression. This prompted us to study CD30 immunohistochemical (IHC) expression and mRNA levels by reverse transcription polymerase chain reaction (RT-PCR) in a different series of 51 cases (43 AITLs and 8 PTCL-NOSs) in routine samples. Double stainings with PAX5/CD30, CD3/CD30, and LEF1/CD30 were performed to study the phenotype of CD30 cells. Most (90%) of the cases showed some level of CD30 expression by IHC (1% to 95%); these levels were high (>50% of tumoral cells) in 14% of cases. CD30 expression was not detected in 10% of the cases. Quantitative RT-PCR results largely confirmed these findings, demonstrating a moderately strong correlation between global CD30 IHC and mRNA levels (r=0.65, P=1.75e-7). Forty-four of the positive cases (98%) contained CD30-positive B cells (PAX5), whereas atypical CD30-positive T cells were detected in 42 cases (93%). In conclusion, our data show that most AITL and PTCL-NOS cases express CD30, exhibiting very variable levels of CD30 expression that may be measured by IHC or RT-PCR techniques.

  18. Downregulation of guanine nucleotide-binding protein beta 1 (GNB1) is associated with worsened prognosis of clearcell renal cell carcinoma and is related to VEGF signaling pathway.

    PubMed

    Chen, C; Chi, H; Min, L; Junhua, Z

    2017-01-01

    Clear-cell renal cell carcinoma (ccRCC) is characterized by genetic abnormalities, while the role of Guanine Nucleotide-Binding Protein Beta 1 (GNB1) in ccRCC has not been studied. We thus aimed to evaluate the expression and prognostic value of GNB1 in ccRCC. A two-stage study (exploration and validation) was conducted using in silico and immunohistochemical (IHC) scoring of ccRCC samples from our institute, to evaluate the association between GNB1 expression and clinicopathological parameters of ccRCC patients. Pathway analyses were performed for genes coexpressed with GNB1 using the KOBAS platform to profile the function of GNB1 and IHC validation. In the exploration stage, data from TCGA ccRCC dataset were reproduced, which contained 537 patients with ccRCC and found that downregulation of GNB1 was significantly associated with worse prognosis. IHC staining from the Human Protein Atlas showed significantly downregulation of GNB1 in ccRCC tissue compared with normal kidney. Pathway analysis showed significantly altered vascular endothelial growth factor (VEGF) signaling pathways among which expressions of 3 genes (WASF2, NRP1, and HIP1) were significantly associated with GNB1 expression, respectively. In the validation stage, included were 80 ccRCC samples and GNB1 expression was scored using IHC positivity. GNB1 expression was negatively associated with tumor stage, lymph node invasion, metastasis, older age, and increased tumor grade. Female gender and receiving neoadjuvant therapy were also associated with decreased GNB1 expression. The expressions of WASF2, NRP1 and HIP1 were also studied and found that they were significantly associated with GNB1. GNB1 was downregulated in ccRCC. Decreased GNB1 expression was associated with worsened disease characteristics and prognosis. GNB1 was related with VEGF signaling in ccRCC, implying a therapeutic potential of this factor.

  19. Ocular melanoma metastatic to skin: the value of HMB-45 staining.

    PubMed

    Schwartz, Robert A; Kist, Joseph M; Thomas, Isabelle; Fernández, Geover; Cruz, Manuel A; Koziorynska, Ewa I; Lambert, W Clark

    2004-06-01

    Cutaneous metastatic disease is an important finding that may represent the first sign of systemic cancer, or, if already known, that may change tumor staging and thus dramatically altered therapeutic plans. Although cutaneous metastases are relatively frequent in patients with cutaneous melanoma, they are less so from ocular melanoma. To demonstrate the value of HMB-45, staining in the detection of ocular melanoma metastatic to skin. The immunohistochemical stain HMB-45 a monoclonal antibody directed against intact human melanoma cells, was employed on a skin biopsy specimen from a cutaneous tumor. HMB-45 staining was positive in the atypical hyperchromatic cells of the deep dermis. HMB-45 may be of value in the detection of ocular melanoma metastatic to skin. Cutaneous metastatic disease is a somewhat common and extremely important diagnosis. Although cutaneous metastases from cutaneous melanoma are relatively frequent, those from ocular melanomas are less so. Use of histochemical staining, especially the HMB-45 stain, allows confirmation of the diagnosis.

  20. Touch cytology in diagnosing Helicobacter pylori: comparison of four staining methods.

    PubMed

    Hashemi, M R; Rahnavardi, M; Bikdeli, B; Dehghani Zahedani, M; Iranmanesh, F

    2008-06-01

    Helicobacter pylori (Hp), a major cause of peptic ulcer disease and an important risk factor for gastric malignancy, can be diagnosed by several methods. Touch cytology (TC) of the gastric mucosa has been noted to give good results and has been found to be very simple, inexpensive and rapid. However, evidence regarding the accuracy of different staining methods of TC is lacking. The present study aims at defining the diagnostic accuracy of four different staining methods of TC. Biopsy specimens were taken from the antral mucosa of one hundred consecutive patients referred for upper gastrointestinal endoscopy (UGIE) for various indications. TC slides were processed by four staining methods: Wright, Giemsa, Papanicolaou and Gram. Rapid urease test (RUT) and histological examination of specimens were also performed. The same experienced pathologist evaluated the coded samples. A patient's Hp status was established by minimum concordance of the three tests, including histology, RUT, and 'Touch mean'. The latter was defined positive when at least three of the four TC staining methods were positive. Forty-six patients (46%) were positive for Hp according to Hp status. TC stained by Wright had excellent agreement with both histology (kappa = 0.80, P < 0.001) and RUT (kappa = 0.84, P < 0.001). Regarding Hp status, histology was 100% sensitive and RUT was 100% specific. Wright-stained TC (88.89%) was significantly more specific than both Giemsa- (74.07%; P < 0.05) and Papanicolaou-stained (70.37%; P < 0.05) TC. RUT should still be acknowledged as the primary test in diagnosing Hp following UGIE. If RUT is negative and Hp detection is intended only, Wright-stained TC can safely substitute for histology. However, when assessment for severity of mucosal damage or cell atypias is meant, histology cannot be neglected.

  1. A comparative clinical study evaluating stain removal efficacy of a new sensitivity whitening dentifrice compared to commercially available whitening dentifrices.

    PubMed

    Hughes, Nathan; Maggio, Brenda; Sufi, Farzana; Mason, Stephen; Kleber, Carl J

    2009-01-01

    To assess the extrinsic stain removal efficacy of a new sensitivity dentifrice containing sodium tripolyphosphate (STP) to marketed whitening toothpastes after six weeks of product use. This was a single-center, double-blind, stratified, six-week clinical study comparing the reduction in stain area and intensity of Sensodyne Extra Whitening to Crest Maximum Strength Sensitivity Protection Whitening plus Scope and Colgate Tartar Control Plus Whitening Mint dentifrice, as measured by MacPherson's Modification of the Lobene Stain Index (MMLSI) in a forced stain model. Two-hundred and ninety-five subjects completed the study. Tooth stain MMSLI scores showed significant differences between Sensodyne and Crest dentifrices in favor of Sensodyne for all surface sites (p = 0.014), and individually for facial (p = 0.023), lingual (p = 0.027), and interproximal (p = 0.014) surfaces. No significant statistical differences between Sensodyne and Colgate dentifrices were observed for any of the surfaces. Results from this stain removal clinical study demonstrate significant extrinsic stain removal efficacy for all dentifrices relative to baseline. Significant differences between the two marketed sensitivity whitening dentifrices were demonstrated in favor of the new Sensodyne Sensitivity Whitening dentifrice.

  2. [Intrapartum amnioinfusion in patients with meconium-stained amniotic fluid].

    PubMed

    Engel, Karina; Samborska, Monika; Bilar, Marek; Sipak-Szmigiel, Olimpia; Ronin-Walknowska, Elzbieta

    2008-09-01

    The aim of the study was to evaluate the effect of intrapartum amnioinfusion in the presence of meconium stained amniotic fluid. 93 women with meconium-stained amniotic fluid were assigned to receive amnioinfusion or no amnioinfusion (128 women). The trials were evaluated for fetal distress syndrome, route of delivery, fetal acidemia, Apgar score at 1 and 5 min., meconium aspiration syndrome, postpartum endometritis and maternal hospital stays. Amnioinfusion in cases of meconium-stained fluid did not improve the number of fetal distress symptoms during fetal heart rate monitoring. Amnioinfusion was associated with a significant decrease of neonatal acidemia although it did not improve Apgar score. In our study amnioinfusion was not associated with reduction in the incidence of neonatal outcome and puerperial complications.

  3. A randomized CIE L*a*b* evaluation of external bleaching therapy effects on fluorotic enamel stains.

    PubMed

    Knösel, Michael; Attin, Rengin; Becker, Klaus; Attin, Thomas

    2008-05-01

    To evaluate the effect of external bleaching on the color and luminosity of fluorotic stains and adjacent, normally mineralized enamel areas by means of CIE L*a*b* colorimetry. Eighteen adolescents with mild to moderate fluorotic stains were randomly assigned to either bleaching group A (n = 9) or control group B. Eligibility criteria were fluorotic stained maxillary incisors or canines and the informed consent of the participants and their guardians. Using a colorimeter, CIE L*a*b* values of maxillary incisors and canines were assessed at baseline (T1) in the center of the fluorotic stained area (F1) and at adjacent, normally mineralized enamel areas (F2). Then, external bleaching with Illumine office (30% hydrogen peroxide, Dentsply DeTrey) was performed for 60 minutes, followed by color reassessment (T2). After 14 days (T3), a 2-week home bleaching period with a daily bleaching time of 1 hour with Illumine home (15% carbamide peroxide, Dentsply DeTrey) was conducted with subsequent color determination (T4). After completion of bleaching therapy, 96.0% of all fluorotic areas (F1) and 100% of normal enamel areas (F2) showed a significant change within group A, compared to 29.4% in control group B. Comparing the collective DeltaE (L*, a*, b*) of F1 and F2, 60.0% of all areas showed significant differences after completion of bleaching therapy, compared to 88.0% initially. Of group B sites, 82.4% showed color differences in the beginning (T1) and 88.2% at the end (T4). Whereas a single 1-hour session of in-office bleaching with 30% hydrogen peroxide does not significantly affect the color and luminosity of fluorotic teeth, a 14-day period of home bleaching leads to an assimilation of the color of the fluorotic stain with the color of surrounding enamel areas due to different responses of sound and fluorotic enamel to the bleaching regime.

  4. Staining human lymphocytes and onion root cell nuclei with madder root.

    PubMed

    Cücer, N; Guler, N; Demirtas, H; Imamoğlu, N

    2005-01-01

    We performed staining experiments on cells using natural dyes and different mordants using techniques that are used for wool and silk dyeing. The natural dye sources were madder root, daisy, corn cockle and yellow weed. Ferrous sulfate, copper sulfate, potassium tartrate, urea, potassium aluminum sulfate and potassium dichromate were used as mordants. Distilled water, distilled water plus ethanol, heptane, and distilled water plus methanol were used as solvents. All dye-mordant-solvent combinations were studied at pH 2.4, 3.2 and 4.2. The generic staining procedure was to boil 5-10 onion roots or stimulated human lymphocyte (SHL) preparations in a dye bath on a hot plate. Cells were examined at every half hour. For multicolor staining, madder-dyed lymphocytes were decolorized, then stained with Giemsa. The AgNOR technique was performed following the decolorization of Giemsa stained lymphocytes. Good results were obtained for both onion root cells and lymphocytes that were boiled for 3 h in a dye bath that included 4 g madder root, 4 g ferrous sulfate as mordant in 50 ml of 1:1 (v/v) methanol:distilled water. The pH was adjusted to 4.2 with 6 ml acetic acid. We conclude that madder root has potential as an alternative dye for staining biological materials.

  5. Statistical modeling, detection, and segmentation of stains in digitized fabric images

    NASA Astrophysics Data System (ADS)

    Gururajan, Arunkumar; Sari-Sarraf, Hamed; Hequet, Eric F.

    2007-02-01

    This paper will describe a novel and automated system based on a computer vision approach, for objective evaluation of stain release on cotton fabrics. Digitized color images of the stained fabrics are obtained, and the pixel values in the color and intensity planes of these images are probabilistically modeled as a Gaussian Mixture Model (GMM). Stain detection is posed as a decision theoretic problem, where the null hypothesis corresponds to absence of a stain. The null hypothesis and the alternate hypothesis mathematically translate into a first order GMM and a second order GMM respectively. The parameters of the GMM are estimated using a modified Expectation-Maximization (EM) algorithm. Minimum Description Length (MDL) is then used as the test statistic to decide the verity of the null hypothesis. The stain is then segmented by a decision rule based on the probability map generated by the EM algorithm. The proposed approach was tested on a dataset of 48 fabric images soiled with stains of ketchup, corn oil, mustard, ragu sauce, revlon makeup and grape juice. The decision theoretic part of the algorithm produced a correct detection rate (true positive) of 93% and a false alarm rate of 5% on these set of images.

  6. Improvement of malaria diagnostic system based on acridine orange staining.

    PubMed

    Kimura, Masatsugu; Teramoto, Isao; Chan, Chim W; Idris, Zulkarnain Md; Kongere, James; Kagaya, Wataru; Kawamoto, Fumihiko; Asada, Ryoko; Isozumi, Rie; Kaneko, Akira

    2018-02-07

    Rapid diagnosis of malaria using acridine orange (AO) staining and a light microscope with a halogen lamp and interference filter was deployed in some malaria-endemic countries. However, it has not been widely adopted because: (1) the lamp was weak as an excitation light and the set-up did not work well under unstable power supply; and, (2) the staining of samples was frequently inconsistent. The halogen lamp was replaced by a low-cost, blue light-emitting diode (LED) lamp. Using a reformulated AO solution, the staining protocol was revised to make use of a concentration gradient instead of uniform staining. To evaluate this new AO diagnostic system, a pilot field study was conducted in the Lake Victoria basin in Kenya. Without staining failure, malaria infection status of about 100 samples was determined on-site per one microscopist per day, using the improved AO diagnostic system. The improved AO diagnosis had both higher overall sensitivity (46.1 vs 38.9%: p = 0.08) and specificity (99.0 vs 96.3%) than the Giemsa method (N = 1018), using PCR diagnosis as the standard. Consistent AO staining of thin blood films and rapid evaluation of malaria parasitaemia with the revised protocol produced superior results relative to the Giemsa method. This AO diagnostic system can be set up easily at low cost using an ordinary light microscope. It may supplement rapid diagnostic tests currently used in clinical settings in malaria-endemic countries, and may be considered as an inexpensive tool for case surveillance in malaria-eliminating countries.

  7. Staining paraffin embedded sections of scald of barley before paraffin removal.

    PubMed

    Xi, K; Burnett, P A

    1997-07-01

    Staining of paraffin embedded sections with periodic acid-Schiff reagent and fast green before paraffin removal resulted in differentiation of barley seed and leaf tissue from fungal structures of Rhynchosporium secalis. Crystal violet, toluidine blue O and antiline blue also successfully stained fungal structures of R. secalis in barley leaf tissues. Staining of embedded sections before paraffin removal allows simple processing of a series of sections, saves time and reduces solvent consumption.

  8. Effect of Photo-Fenton Bleaching on Tetracycline-stained Dentin in vitro.

    PubMed

    Bennett, Zackary Yale; Walsh, Laurence James

    2015-02-01

    Tetracycline-stained tooth structure is difficult to bleach using nightguard tray methods. The possible benefits of in-office light-accelerated bleaching systems based on the photo-Fenton reaction are of interest as possible adjunctive treatments. This study was a proof of concept for possible benefits of this approach, using dentine slabs from human tooth roots stained in a reproducible manner with the tetracycline antibiotic demeclocycline hydrochloride. Color changes overtime in tetra-cycline stained roots from single rooted teeth treated using gel (Zoom! WhiteSpeed(®)) alone, blue LED light alone, or gel plus light in combination were tracked using standardized digital photography. Controls received no treatment. Changes in color channel data were tracked overtime, for each treatment group (N = 20 per group). Dentin was lighter after bleaching, with significant improvements in the dentin color for the blue channel (yellow shade) followed by the green channel and luminosity. The greatest changes occurred with gel activated by light (p < 0.0001), which was superior to effects seen with gel alone. Use of the light alone did not significantly alter shade. This proof of concept study demonstrates that bleaching using the photo-Fenton chemistry is capable of lightening tetracycline-stained dentine. Further investigation of the use of this method for treating tetracycline-stained teeth in clinical settings appears warranted. Because tetracycline staining may respond to bleaching treatments based on the photo-Fenton reaction, systems, such as Zoom! WhiteSpeed, may have benefits as adjuncts to home bleaching for patients with tetracycline-staining.

  9. Comparative study between quantitative digital image analysis and fluorescence in situ hybridization of breast cancer equivocal human epidermal growth factor receptors 2 score 2(+) cases.

    PubMed

    Ayad, Essam; Mansy, Mina; Elwi, Dalal; Salem, Mostafa; Salama, Mohamed; Kayser, Klaus

    2015-01-01

    Optimization of workflow for breast cancer samples with equivocal human epidermal growth factor receptors 2 (HER2)/neu score 2(+) results in routine practice, remains to be a central focus of the on-going efforts to assess HER2 status. According to the College of American Pathologists/American Society of Clinical Oncology guidelines equivocal HER2/neu score 2(+) cases are subject for further testing, usually by fluorescence in situ hybridization (FISH) investigations. It still remains on open question, whether quantitative digital image analysis of HER2 immunohistochemistry (IHC) stained slides can assist in further refining the HER2 score 2(+). To assess utility of quantitative digital analysis of IHC stained slides and compare its performance to FISH in cases of breast cancer with equivocal HER2 score 2(+). Fifteen specimens (previously diagnosed as breast cancer and was evaluated as HER 2(-) score 2(+)) represented the study population. Contemporary new cuts were prepared for re-evaluation of HER2 immunohistochemical studies and FISH examination. All the cases were digitally scanned by iScan (Produced by BioImagene [Now Roche-Ventana]). The IHC signals of HER2 were measured using an automated image analyzing system (MECES, www.Diagnomx.eu/meces). Finally, a comparative study was done between the results of the FISH and the quantitative analysis of the virtual slides. Three out of the 15 cases with equivocal HER2 score 2(+), turned out to be positive (3(+)) by quantitative digital analysis, and 12 were found to be negative in FISH too. Two of these three positive cases proved to be positive with FISH, and only one was negative. Quantitative digital analysis is highly sensitive and relatively specific when compared to FISH in detecting HER2/neu overexpression. Therefore, it represents a potential reliable substitute for FISH in breast cancer cases, which desire further refinement of equivocal IHC results.

  10. Role of CD248 as a potential severity marker in idiopathic pulmonary fibrosis.

    PubMed

    Bartis, Domokos; Crowley, Louise E; D'Souza, Vijay K; Borthwick, Lee; Fisher, Andrew J; Croft, Adam P; Pongrácz, Judit E; Thompson, Richard; Langman, Gerald; Buckley, Christopher D; Thickett, David R

    2016-04-14

    CD248 or Endosialin is a transmembrane molecule expressed in stromal cells binding to extracellular matrix (ECM) components. It has been previously implicated in kidney fibrosis, rheumatoid arthritis as well as in tumour-stromal interactions. This study investigates the role of CD248 in the pathogenesis of fibrotic diseases in Idiopathic Pulmonary Fibrosis (IPF). CD248 quantitative immunohistochemistry (IHC) was performed on lung samples from 22 IPF patients and its expression was assayed in cultured pulmonary fibroblasts and epithelial cells. Effects of CD248 silencing was evaluated on fibroblast proliferation and myofibroblast differentiation. IHC revealed strong CD248 expression in mesenchymal cells of normal lung structures such as pleura and adventitia but not in epithelium. Fibrotic areas showed markedly stronger staining than unaffected lung tissue. The extent of CD248 staining showed a significant negative correlation to lung function parameters FEV1, FVC, TLC, and TLCO (r2 > 0 · 35, p < 0 · 01). CD248 protein levels were significantly greater in IPF-derived lung fibroblasts vs normal lung fibroblasts (p < 0 · 01) and CD248 silencing significantly reduced the proliferation of lung fibroblasts, but did not affected myofibroblast differentiation. We conclude that CD248 overexpression is possibly involved in the pathogenesis of IPF and it has potential as a disease severity marker. Given that CD248 ligands are collagen type I, IV and fibronectin, we hypothesise that CD248 signalling represents a novel matrix-fibroblast interaction that may be a potential therapeutic target in IPF.

  11. Rapid alkaline methylene blue supravital staining for assessment of anterior segment infections.

    PubMed

    Kiuchi, Katsuji

    2016-01-01

    To present the Löffler's alkaline methylene blue technique of staining eye discharges in eyes with anterior segment infections. The Löffler's alkaline methylene blue staining method is a simple staining technique that can be used to differentiate bacterial, viral, and fungal infections. It is a cationic dye that stains cells blue because the positively charged dye is attracted to negatively charged particles such as polyphosphates, DNAs, and RNAs. Specimens collected from patients by swabbing are smeared onto microscope slides and the methylene blue solution is dropped on the slide. The slide is covered with a glass cover slip and examined under a microscope. The entire time from the collection to the viewing is about 30 seconds. Histopathological images of the conjunctival epithelial cells and neutrophils in eye discharges were dyed blue and the nuclei were stained more intensely blue. Bacterial infections consisted mainly of neutrophils, and viral infections consisted mainly of lymphocytes. Löffler's alkaline methylene blue staining can be done in about 30 seconds for diagnosis. Even though this is a one color stain, it is possible to infer the cause of the infection by detection of the absence of bacteria and/or fungi in context of the differential distribution of neutrophils and lymphocytes.

  12. [Automated analysis of bacterial preparations manufactured on automatic heat fixation and staining equipment].

    PubMed

    2012-01-01

    Heat fixation of preparations was made in the fixation bath designed by EMKO (Russia). Programmable "Emkosteiner" (EMKO, Russia) was used for trial staining. Reagents set Micko-GRAM-NITsF was applied for Gram's method of staining. It was demostrated that automatic smear fixation equipment and programmable staining ensure high-quality imaging (1% chromaticity variation) good enough for standardization of Gram's staining of microbial preparations.

  13. Mechanisms of superficial micropunctate corneal staining with sodium fluorescein: the contribution of pooling.

    PubMed

    Bandamwar, Kalika L; Garrett, Qian; Papas, Eric B

    2012-04-01

    To establish if sodium fluorescein (SFL) dye accumulation within intercellular spaces on the ocular surface contributes to the appearance of superficial punctate corneal staining. Thirteen subjects bilaterally wore PureVision™ lenses that had been pre-soaked in ReNu MultiPlus® multipurpose solution. After 1h of lens wear, corneal staining with SFL was assessed using a standard slit-lamp technique. Participants who presented with bilateral, corneal staining were selected for further evaluation. A randomly selected eye was rinsed with saline three times. Fellow eyes (control) received no rinsing. After each rinse, the appearance of SFL staining was recorded without any further instillation of the dye. To eliminate any confounding effects of staining due to residual fluorescein in the tear menisci, corneal staining was induced in freshly excised, isolated, rabbit eyes by topical administration of 0.001% PHMB and staining, rinsing and grading were performed as above. Nine out of 13 subjects presented with bilateral diffuse corneal staining (mean grade±SD: 2.4±0.7). The mean staining grades in test and control eyes respectively after each of the three rinses were (1) 2.41±0.41, 2.25±0.69 (p=0.9); (2) 2.34±0.79, 2.1±0.83 (p=0.8); and (3) 1.71±0.65, 1.60±0.79 (p=0.6) there was no significant reduction in staining with rinsing (p>0.05) and no difference was observed between test and control eyes at any sampling-point. Similar observations made in ex vivo rabbit eyes replicated these results. Pooling or accumulation of SFL solution within intercellular spaces does not appear to contribute to the appearance of superficial micropunctate corneal staining. Copyright © 2011 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  14. Routine Use of Adjunctive p16 Immunohistochemistry Improves Diagnostic Agreement of Cervical Biopsy Interpretation: Results From the CERTAIN Study.

    PubMed

    Stoler, Mark H; Wright, Thomas C; Ferenczy, Alex; Ranger-Moore, James; Fang, Qijun; Kapadia, Monesh; Ridder, Ruediger

    2018-04-24

    The diagnosis of squamous intraepithelial lesions in cervical tissue specimens is subject to substantial variability. Adjunctive immunohistochemical (IHC) staining for p16 has been shown to add objective biomarker information to morphologic interpretation of hematoxylin and eosin (H&E)-stained tissues. In the CERvical Tissue AdjunctIve aNalysis (CERTAIN) study, we systematically analyzed the impact of adjunctive p16 IHC on the accuracy (agreement with reference pathology results) of diagnosing cervical intraepithelial neoplasia of grade 2 or worse (CIN2+) in the United States. Eleven hundred cervical biopsies were divided into 4 sets of 275 cases by stratified randomization. All H&E slides from each set were interpreted by 17 to 18 individual surgical pathologists, for a total of 19,250 reads by 70 surgical pathologists. After a wash-out period and blinding to original results, cases were re-read by the same pathologists using H&E+p16-stained slides. Using expert consensus diagnoses on H&E+p16 as reference, adjunctive p16 IHC use significantly improved diagnostic agreement of surgical pathologists by 4.7% (95% confidence interval [CI], 3.9, 5.4; P<0.0001). This improvement was driven by an increase of 11.5% (95% CI, 9.3, 13.5; P<0.0001) in sensitivity and an increase of 3.0% (95% CI, 2.2, 3.7; P<0.0001) in specificity. Diagnostic performance was significantly increased as well when expert consensus diagnoses established on H&E only was used as reference. Furthermore, interobserver reliability improved significantly from moderate (H&E: κ=0.58) to substantial (H&E+p16: κ=0.73; P<0.0001). Adjunctive use of p16 IHC provides more accurate and reproducible diagnostic results in the interpretation of cervical biopsies, ensuring that more patients are treated correctly without treating more patients.This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible

  15. In-gel staining of proteins in native polyacrylamide gel electrophoresis using meso-tetrakis(4-sulfonatophenyl) porphyrin.

    PubMed

    Divakar, K; Devi, G Nandhini; Gautam, Pennathur

    2012-01-01

    Protein identification in polyacrylamide gel electrophoresis (PAGE) requires post-electrophoretic steps like fixing, staining, and destaining of the gel, which are time-consuming and cumbersome. A new method for direct visualization of protein bands in PAGE has been developed using meso-tetrakis(4-sulfonatophenyl)porphyrin (TPPS) as a dye without the need for any post-electrophoretic steps; thus, separation and recovery of enzymes become much easier for further analysis. Activity staining was carried out to show that the biochemical activity of the enzymes was preserved after electrophoresis.

  16. Stain removal and whitening by baking soda dentifrice: A review of literature.

    PubMed

    Li, Yiming

    2017-11-01

    Tooth discoloration may be caused by intrinsic or extrinsic stains or a combination of both. There are 2 major approaches to removing the stains, including the chemical mechanism using peroxides for tooth bleaching and the mechanical mechanism using abrasives in prophylactic pastes and dentifrices to remove stains, resulting in a whitening effect. Attempts have also been made to add a low concentration of peroxides to dentifrices to enhance their abrasive cleaning to remove tooth stains. This article provides a review of both in vitro and clinical studies on stain removal and whitening effect of dentifrices containing sodium bicarbonate (baking soda). In recent years, whitening dentifrices have become popular because of little additional effort for use, ease of availability, low cost, and accumulated evidence of clinical efficacy and safety in the literature. Advances in research and technology have led to innovative formulations of dentifrices using baking soda as the sole abrasive or a component of an abrasive system. Baking soda is biologically compatible with acid-buffering capacities, antibacterial at high concentrations, and has a relatively lower abrasivity. The evidence available in the literature indicates that baking soda-based dentifrices are effective and safe for tooth stain removal and consequently whitening. A number of clinical studies have also shown that baking soda-based dentifrices are more effective in stain removal and whitening than some non-baking soda-containing dentifrices with a higher abrasivity. So far, research efforts have mainly focused on stain removal and tooth-whitening efficacy and clinical safety of baking soda dentifrices used with manual toothbrushes, with only a few studies investigating their effects using powered toothbrushes, for which further research is encouraged. As part of a daily oral hygiene practice, baking soda-based dentifrice is a desirable, alternative or additional measure for tooth stain removal and whitening

  17. Organic staining on bone from exposure to wood and other plant materials.

    PubMed

    Pollock, Corey R; Pokines, James T; Bethard, Jonathan D

    2018-02-01

    Determining the depositional environment and the postmortem alterations to a set of remains are necessary aspects of a forensic investigation to explain the circumstances surrounding the death of an individual. The present study examines organic staining as a method for reconstructing the depositional environment of skeletal remains and the taphonomic agents with which they came into contact. Organic staining results largely from tannins leaching from plant materials and therefore can be seen on bone deposited in wooden coffin environments or on terrestrial surfaces. The present study examines the hypothesis that the degree of staining observed on skeletal elements would increase as the length of exposure to the organic matter increased and that different plant materials and environments would leave different patterns or colorations of staining. The sample consisted of 165 pig (Sus scrofa) femora divided into four groups exposed to differing experimental conditions, including burial in direct contact with soil or burial in a simulated coffin environment, immersion in water with wood samples, and surface deposition with plant matter contact. The bones were removed once a month from their experimental environments and the level of staining was recorded qualitatively using the Munsell Soil Color Chart. In all of the experimental environments, staining was present after two months of exposure, and the color darkened across the bone surface with each episode of data collection. The results from the present study indicate that staining can manifest on bone within a relatively short time frame once skeletonization occurs and a variety of colorations or patterns of staining can manifest based on the plant material. The present research also demonstrates the potential of organic staining to aid in estimations of the postmortem interval as well as a depositional environmental reconstruction through plant species identification. Copyright © 2017 Elsevier B.V. All rights

  18. Microbiological and histopathological findings in cases of fatal bovine respiratory disease of feedlot cattle in Western Canada.

    PubMed

    Booker, Calvin W; Abutarbush, Sameeh M; Morley, Paul S; Jim, G Kee; Pittman, Tom J; Schunicht, Oliver C; Perrett, Tye; Wildman, Brian K; Fenton, R Kent; Guichon, P Timothy; Janzen, Eugene D

    2008-05-01

    The aim of this study was to describe the microbiologic agents and pathologic processes in fatal bovine respiratory disease (BRD) of feedlot cattle and to investigate associations between agents and pathologic processes. Ninety feedlot calves diagnosed at necropsy with BRD and 9 control calves without BRD were examined, using immunohistochemical (IHC) staining and histopathologic studies. Mannheimia haemolytica (MH) (peracute, acute, and subacute cases) and Mycoplasma bovis (MB) (subacute, bronchiolar, and chronic cases) were the most common agents identified in fatal BRD cases. Significant associations (P < 0.10) were detected between microbiologic agents and between agents and pathologic processes. When IHC staining was used, 25/26 (96%) of animals that were positive for bovine viral diarrhea virus (BVDV) were also positive for MH; 12/15 (80 %) of animals that were positive for Histophilus somni (HS) were also positive for MB; and all of the animals that were positive for HS were negative for MH and BVDV. This quantitative pathological study demonstrates that several etiologic agents and pathologic processes are involved in fatal BRD of feedlot cattle.

  19. Microbiological and histopathological findings in cases of fatal bovine respiratory disease of feedlot cattle in western Canada

    PubMed Central

    Booker, Calvin W.; Abutarbush, Sameeh M.; Morley, Paul S.; Jim, G. Kee; Pittman, Tom J.; Schunicht, Oliver C.; Perrett, Tye; Wildman, Brian K.; Fenton, R. Kent; Guichon, P. Timothy; Janzen, Eugene D.

    2008-01-01

    The aim of this study was to describe the microbiologic agents and pathologic processes in fatal bovine respiratory disease (BRD) of feedlot cattle and to investigate associations between agents and pathologic processes. Ninety feedlot calves diagnosed at necropsy with BRD and 9 control calves without BRD were examined, using immunohistochemical (IHC) staining and histopathologic studies. Mannheimia haemolytica (MH) (peracute, acute, and subacute cases) and Mycoplasma bovis (MB) (subacute, bronchiolar, and chronic cases) were the most common agents identified in fatal BRD cases. Significant associations (P < 0.10) were detected between microbiologic agents and between agents and pathologic processes. When IHC staining was used, 25/26 (96%) of animals that were positive for bovine viral diarrhea virus (BVDV) were also positive for MH; 12/15 (80 %) of animals that were positive for Histophilus somni (HS) were also positive for MB; and all of the animals that were positive for HS were negative for MH and BVDV. This quantitative pathological study demonstrates that several etiologic agents and pathologic processes are involved in fatal BRD of feedlot cattle. PMID:18512458

  20. Ergosterol peroxide from Chaga mushroom (Inonotus obliquus) exhibits anti-cancer activity by down-regulation of the β-catenin pathway in colorectal cancer.

    PubMed

    Kang, Ju-Hee; Jang, Jeong-Eun; Mishra, Siddhartha Kumar; Lee, Hee-Ju; Nho, Chu Won; Shin, Dongyun; Jin, Mirim; Kim, Mi Kyung; Choi, Changsun; Oh, Seung Hyun

    2015-09-15

    In this study, we examined the effect of different fractions and components of Chaga mushroom (Inonotus Obliquus) on viability and apoptosis of colon cancer cells. Among them, one component showed the most effective growth inhibition and was identified as ergosterol peroxide by NMR analysis. We investigated the anti-proliferative and apoptosis mechanisms of ergosterol peroxide associated with its anti-cancer activities in human colorectal cancer (CRC) cell lines and tested its anti-tumor effect on colitis-induced CRC developed by Azoxymethane (AOM)/Dextran sulfate sodium (DSS) in a mouse model. We used MTT (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) assays, flow cytometry assays, Western blot analysis, colony formation assays, reverse transcription-polymerase chain reaction (RT-PCR), immunohistochemistry (IHC), and AOM/DSS mouse models to study the molecular mechanism of metastatic activities in CRC cells. Ergosterol peroxide inhibited cell proliferation and also suppressed clonogenic colony formation in HCT116, HT-29, SW620 and DLD-1 CRC cell lines. The growth inhibition observed in these CRC cell lines was the result of apoptosis, which was confirmed by FACS analysis and Western blotting. Ergosterol peroxide inhibited the nuclear levels of β-catenin, which ultimately resulted in reduced transcription of c-Myc, cyclin D1, and CDK-8. Ergosterol peroxide administration showed a tendency to suppress tumor growth in the colon of AOM/DSS-treated mice, and quantification of the IHC staining showed a dramatic decrease in the Ki67-positive staining and an increase in the TUNEL staining of colonic epithelial cells in AOM/DSS-treated mice by ergosterol peroxide for both prevention and therapy. Our data suggest that ergosterol peroxide suppresses the proliferation of CRC cell lines and effectively inhibits colitis-associated colon cancer in AOM/DSS-treated mice. Ergosterol peroxide down-regulated β-catenin signaling, which exerted anti-proliferative and

  1. Is the gram stain useful in the microbiologic diagnosis of VAP? A meta-analysis.

    PubMed

    O'Horo, John C; Thompson, Deb; Safdar, Nasia

    2012-08-01

    In a meta-analysis examining respiratory specimen Gram stain for diagnosis of ventilator-associated pneumonia, absence of bacteria on Gram stain had a high negative predictive value, but a positive Gram stain correlated poorly with organisms recovered in culture. Rapid and accurate diagnosis of ventilator-associated pneumonia (VAP) is a major challenge and no generally accepted gold standard exists for VAP diagnosis. We conducted a meta-analysis to examine the role of respiratory specimen Gram stain to diagnose VAP, and the correlation with final culture results. In 21 studies, pooled sensitivity of Gram stain for VAP was 0.79 (95% confidence interval [CI], .77-0.81; P < .0001) and specificity was 0.75 (95% CI, .73-.78; P < .0001). Negative predictive value of Gram stain for a VAP prevalence of 20%-30% was 91%, suggesting that VAP is unlikely with a negative Gram stain but the positive predictive value of Gram stain was only 40%. Pooled kappa was 0.42 for gram-positive organisms and 0.34 for gram-negative organisms, suggesting fair concordance between organisms on Gram stain and recovery by culture. Therefore, a positive Gram stain should not be used to narrow anti-infective therapy until culture results become available.

  2. Clinical outcomes of double staining and additional ILM peeling during ERM surgery.

    PubMed

    Oh, Ha Na; Lee, Joo Eun; Kim, Hyun Woong; Yun, Il Han

    2013-08-01

    To assess the clinical outcomes in idiopathic epiretinal membrane (ERM) patients after vitrectomy and ERM removal with or without additional indocyanine green (ICG)-assisted internal limiting membrane (ILM) peeling. The medical records of 43 patients with an idiopathic ERM that underwent vitrectomy and ERM removal between July 2007 and April 2010 were reviewed. The patients were divided into two groups: triamcinolone-assisted simple ERM peeling only (group A, n = 23) and triamcinolone-assisted ERM peeling followed by ICG staining and peeling of the remaining internal ILM (group B, n = 20). No difference was found between the two groups in terms of visual acuity, macular thickness, P1 amplitude or implicit time on multifocal-electroretinogram (mfERG) at six and 12 months postoperatively. In group B, ICG staining after ERM peeling demonstrated that the ILM had been removed together with the ERM in 12 eyes (60%), and all 12 eyes showed punctate retinal hemorrhages during ERM peeling. There was no recurrence of an ERM in either group. Additional procedures involving ICG staining and ILM peeling during ERM surgery do not appear to have an additive effect on the clinical outcomes in terms of visual acuity, retinal function based on mfERG, or recurrence rate.

  3. New visible and selective DNA staining method in gels with tetrazolium salts.

    PubMed

    Paredes, Aaron J; Naranjo-Palma, Tatiana; Alfaro-Valdés, Hilda M; Barriga, Andrés; Babul, Jorge; Wilson, Christian A M

    2017-01-15

    DNA staining in gels has historically been carried out using silver staining and fluorescent dyes like ethidium bromide and SYBR Green I (SGI). Using fluorescent dyes allows recovery of the analyte, but requires instruments such as a transilluminator or fluorimeter to visualize the DNA. Here we described a new and simple method that allows DNA visualization to the naked eye by generating a colored precipitate. It works by soaking the acrylamide or agarose DNA gel in SGI and nitro blue tetrazolium (NBT) solution that, when exposed to sunlight, produces a purple insoluble formazan precipitate that remains in the gel after exposure to light. A calibration curve made with a DNA standard established a detection limit of approximately 180 pg/band at 500 bp. Selectivity of this assay was determined using different biomolecules, demonstrating a high selectivity for DNA. Integrity and functionality of the DNA recovered from gels was determined by enzymatic cutting with a restriction enzyme and by transforming competent cells after the different staining methods, respectively. Our method showed the best performance among the dyes employed. Based on its specificity, low cost and its adequacy for field work, this new methodology has enormous potential benefits to research and industry. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Characterization of HIFU ablation using DNA fragmentation labeling as apoptosis stain

    NASA Astrophysics Data System (ADS)

    Anquez, Jeremie; Corréas, Jean-Michel; Pau, Bernard; Lacoste, François; Yon, Sylvain

    2012-11-01

    The goal of this work was to compare modalities to precisely quantify the extent of thermally induced lesions: gross pathology vs. histopathology vs. devascularization. Liver areas of 14 rabbits were targeted with HIFU and RF ablations in an acute study. Contrast enhanced computorized tomography (CE-CT) scan images were acquired two hours after HIFU and RF treatment to obtain the devascularized volumes of the livers. The animals were then euthanized and deep frozen. The livers were sliced and each slice was photographed and stacked yielding a volume of gross pathology. The volume VGP of the HIFU lesions were derived. The area AGP of the lesions were computed on a particular slice. The lesions were segmented as hypo intense (devascularized) regions on CE-CT images and their volumes VC were computed. The ratios VC/VGP were computed for all the HIFU lesions on all the 14 subjects with a mean value of 1.2. Histology was performed on the livers using Hematoxyline Eosine Staining (HES) and DNA Fragmentation labeling (TUNEL® technology) which characterizes apoptosis. Apoptotic regions of area AT were segmented on the images stained by TUNEL®. No necrosis was identified on the HES data. While TUNEL® did not mark the cores of the RF lesions as apoptotic, the periphery of HIFU and RF lesions was always recognized with TUNEL® as apoptotic. The ratio AGP/AT was computed. The mean value was 0.95 and 0.25 for HIFU and RF lesions respectively. These findings show that the devascularized territory seen on CE-CT scan coincide with the coagulated territories seen with gross pathology. Those actually correspond to cells in apoptosis. It is confirmed that HES stain does not show necrosis 2 hours after thermal ablation. TUNEL® technology for DNA fragmentation labeling appears as a useful marker for thermally induced acute lesions in the liver.

  5. Lymphocytic gastritis is not associated with active Helicobacter pylori infection.

    PubMed

    Nielsen, Jennifer A; Roberts, Cory A; Lager, Donna J; Putcha, Rajesh V; Jain, Rajeev; Lewin, Matthew

    2014-10-01

    Lymphocytic gastritis (LG), characterized by marked intra-epithelial lymphocytosis in the gastric mucosa, has been frequently associated with both celiac disease (CD) and H. pylori gastritis. The aim of this study was to review and correlate the morphology of LG with the presence of CD and H. pylori. Gastric biopsies diagnosed with LG from 1/1/2006 to 8/1/2013 at our institution and corresponding small bowel biopsies, when available, were reviewed for verification of the diagnosis and to assess for the presence of H. pylori and CD. Immunohistochemical (IHC) staining for H. pylori was performed on all gastric biopsies. Demographic, clinical, and laboratory data were obtained from the medical record. Fifty-four of the 56 cases that met inclusion criteria demonstrated significant intra-epithelial lymphocytosis as the predominant histologic abnormality; however, none were associated with H. pylori infection by IHC staining. Two cases that also showed a prominent intra-epithelial and lamina propria neutrophilic infiltrate were both positive for H. pylori and were excluded from further study. Of the 36 small bowel biopsies available, 19 (53%) showed changes in CD. LG is not a distinct clinicopathologic entity, but a morphologic pattern of gastric injury that can be secondary to a variety of underlying etiologies. When restricted to cases with lymphocytosis alone, LG is strongly associated with CD and not with active H. pylori infection. However, cases that also show significant neutrophilic infiltrate should be regarded as "active chronic gastritis" and are often associated with H. pylori infection. A morphologic diagnosis of LG should prompt clinical and serologic workup to exclude underlying CD. © 2014 John Wiley & Sons Ltd.

  6. Diagnostic utility of melanin production by fungi: study on tissue sections and culture smears with Masson-Fontana stain.

    PubMed

    Sundaram, Challa; Shantveer, G Uppin; Umabala, Pamidi; Lakshmi, Vemu

    2014-01-01

    Dematiaceous fungi appear brown in tissue section due to melanin in their cell walls. When the brown color is not seen on routine H and E and culture is not available, differentiation of dematiaceous fungi from other fungi is difficult on morphology alone. To study if melanin production by dematiaceous fungi can help differentiate them from other types of fungi. Fifty tissue sections of various fungal infections and 13 smears from cultures of different species of fungi were stained with Masson Fontana stain to assess melanin production. The tissue sections included biopsies from 26 culture-proven fungi and 24 biopsies of filamentous fungi diagnosed on morphology alone with no culture confirmation. All culture-proven dematiaceous fungi and Zygomycetes showed strong positivity in sections and culture smears. Aspergillus sp showed variable positivity and intensity. Cryptococcus neoformans showed strong positivity in tissue sections and culture smears. Tissue sections of septate filamentous fungi (9/15), Zygomycetes (4/5), and fungi with both hyphal and yeast morphology (4/4) showed positivity for melanin. The septate filamentous fungi negative for melanin were from biopsy samples of fungal sinusitis including both allergic and invasive fungal sinusitis and colonizing fungal balls. Melanin is produced by both dematiaceous and non-dematiaceous fungi. Masson-Fontana stain cannot reliably differentiate dematiaceous fungi from other filamentous fungi like Aspergillus sp; however, absence of melanin in the hyphae may be used to rule out dematiaceous fungi from other filamentous fungi. In the differential diagnosis of yeast fungi, Cryptococcus sp can be differentiated from Candida sp by Masson-Fontana stain in tissue sections.

  7. 2. VIEW SOUTH SHOWING NORTHEAST ELEVATION; BRICK CORBELLING, BUTTRESSES AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. VIEW SOUTH SHOWING NORTHEAST ELEVATION; BRICK CORBELLING, BUTTRESSES AND ART DECO STAINED GLASS - Poletown Historic District, St. Michael's Greek Catholic Church, 2390 East Grand Boulevard, Detroit, MI

  8. Utility of Gram stain for the microbiological analysis of burn wound surfaces.

    PubMed

    Elsayed, Sameer; Gregson, Daniel B; Lloyd, Tracie; Crichton, Marilyn; Church, Deirdre L

    2003-11-01

    Surface swab cultures have attracted attention as a potential alternative to biopsy histology or quantitative culture methods for microbiological burn wound monitoring. To our knowledge, the utility of adding a Gram-stained slide in this context has not been evaluated previously. To determine the degree of correlation of Gram stain with culture for the microbiological analysis of burn wound surfaces. Prospective laboratory analysis. Urban health region/centralized diagnostic microbiology laboratory. Burn patients hospitalized in any Calgary Health Region burn center from November 2000 to September 2001. Gram stain plus culture of burn wound surface swab specimens obtained during routine dressing changes or based on clinical signs of infection. Degree of correlation (complete, high, partial, none), including weighted kappa statistic (kappa(w)), of Gram stain with culture based on quantitative microscopy and degree of culture growth. A total of 375 specimens from 50 burn patients were evaluated. Of these, 239 were negative by culture and Gram stain, 7 were positive by Gram stain only, 89 were positive by culture only, and 40 were positive by both methods. The degree of complete, high, partial, and no correlation of Gram stain with culture was 70.9% (266/375), 1.1% (4/375), 2.4% (9/375), and 25.6% (96/375), respectively. The degree of correlation for all 375 specimens, as expressed by the weighted kappa statistic, was found to be fair (kappa(w) = 0.32).Conclusion.-The Gram stain is not suitable for the microbiological analysis of burn wound surfaces.

  9. Chemical aspects of santalin as a histological stain.

    PubMed

    Banerjee, A; Mukherjee, A K

    1981-03-01

    Recent research on the chemical nature of the red dyes isolated from Pterocarpus santalinus and certain West African plants, viz., Baphia nitida, Pterocarpus osun and Pterocarpus soyauxii, have been reviewed. P. santalinus contains santalins A, B and C, but no santarubin. Santalins and santarubins have been found in P. osun, P. soyauxii and B. nitida. The structural formulae of the santalins are presented and their differences from santarubins indicated. Santalins A and B have some similarities in structure with hematein. This is probably responsible for their staining properties; the possible mechanism of staining is discussed.

  10. Systematic investigation of drip stains on apparel fabrics: The effects of prior-laundering, fibre content and fabric structure on final stain appearance.

    PubMed

    de Castro, Therese C; Taylor, Michael C; Kieser, Jules A; Carr, Debra J; Duncan, W

    2015-05-01

    Bloodstain pattern analysis is the investigation of blood deposited at crime scenes and the interpretation of that pattern. The surface that the blood gets deposited onto could distort the appearance of the bloodstain. The interaction of blood and apparel fabrics is in its infancy, but the interaction of liquids and apparel fabrics has been well documented and investigated in the field of textile science (e.g. the processes of wetting and wicking of fluids on fibres, yarns and fabrics). A systematic study on the final appearance of drip stains on torso apparel fabrics (100% cotton plain woven, 100% polyester plain woven, blend of polyester and cotton plain woven and 100% cotton single jersey knit) that had been laundered for six, 26 and 52 cycles prior to testing was investigated in the paper. The relationship between drop velocity (1.66±0.50m/s, 4.07±0.03m/s, 5.34±0.18m/s) and the stain characteristics (parent stain area, axes 1 and 2 and number of satellite stains) for each fabric was examined using analysis of variance. The experimental design and effect of storing blood were investigated on a reference sample, which indicated that the day (up to five days) at which the drops were generated did not affect the bloodstain. The effect of prior-laundering (six, 26 and 52 laundering cycles), fibre content (cotton vs. polyester vs. blend) and fabric structure (plain woven vs. single jersey knit) on the final appearance of the bloodstain were investigated. Distortion in the bloodstains produced on non-laundered fabrics indicated the importance of laundering fabrics to remove finishing treatments before conducting bloodstain experiments. For laundered fabrics, both the cotton fabrics and the blend had a circular to oval stain appearance, while the polyester fabric had a circular appearance with evidence of spread along the warp and weft yarns, which resulted in square-like stains at the lowest drop velocity. A significant (p<0.001) increase in the stain size on

  11. Utility of Acridine Orange staining for detection of bacteria from positive blood cultures.

    PubMed

    Neeraja, M; Lakshmi, V; Padmasri, C; Padmaja, K

    2017-08-01

    The diagnostic performance of AO stain was evaluated for the detection of bacteria and or fungi from positive blood cultures. The sensitivity of Gram stain (GS) was 98.26% while Acridine Orange (AO) stain proved to be more sensitive (100%) with a Positive and Negative Predictive Value of 100% each. The specificity of both the stains was 100%. Overall agreement between the two stains was 98.23% (688/700). The organisms that were missed by GS and positive by AO were Candida species (Sutton, 2006) and Gram negative bacilli (GNB) (Sutton, 2006). Sensitivity of GS was 82.35% and AO was 100% among mixed cultures. Immediate reporting of the results of AO stain would have a significant impact on clinical management of patients with serious blood stream infections. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. A Rapid Method Combining Golgi and Nissl Staining to Study Neuronal Morphology and Cytoarchitecture

    PubMed Central

    Pilati, Nadia; Barker, Matthew; Panteleimonitis, Sofoklis; Donga, Revers; Hamann, Martine

    2008-01-01

    The Golgi silver impregnation technique gives detailed information on neuronal morphology of the few neurons it labels, whereas the majority remain unstained. In contrast, the Nissl staining technique allows for consistent labeling of the whole neuronal population but gives very limited information on neuronal morphology. Most studies characterizing neuronal cell types in the context of their distribution within the tissue slice tend to use the Golgi silver impregnation technique for neuronal morphology followed by deimpregnation as a prerequisite for showing that neuron's histological location by subsequent Nissl staining. Here, we describe a rapid method combining Golgi silver impregnation with cresyl violet staining that provides a useful and simple approach to combining cellular morphology with cytoarchitecture without the need for deimpregnating the tissue. Our method allowed us to identify neurons of the facial nucleus and the supratrigeminal nucleus, as well as assessing cellular distribution within layers of the dorsal cochlear nucleus. With this method, we also have been able to directly compare morphological characteristics of neuronal somata at the dorsal cochlear nucleus when labeled with cresyl violet with those obtained with the Golgi method, and we found that cresyl violet–labeled cell bodies appear smaller at high cellular densities. Our observation suggests that cresyl violet staining is inadequate to quantify differences in soma sizes. (J Histochem Cytochem 56:539–550, 2008) PMID:18285350

  13. Recognition of Pneumocystis carinii by gram stain in impression smears of lung tissue.

    PubMed Central

    Felegie, T P; Pasculle, A W; Dekker, A

    1984-01-01

    In 12 of 20 (60%) biopsy-proven cases of Pneumocystis carinii pneumonia, the diagnosis was first suggested by examination of routine Gram stains of impression smears made from infected lung tissue and later confirmed by methenamine-silver staining. The cysts appeared as 5- to 7-microns unstained spheres, each containing six to eight intracystic gram-negative bodies (sporozoites). Although the Gram stain does not appear to be as sensitive as more traditional staining techniques for the detection of P. carinii, clinical microbiologists should be aware of the morphology of this organism in gram-stained specimens because this relatively simple procedure gives quick results. Images PMID:6084017

  14. Expression Analysis of p16, c-Myc, and mSin3A in Non-small Cell Lung Cancer by Computer Aided Scoring and Analysis (CASA).

    PubMed

    Salmaninejad, Arash; Estiar, Mehrdad Asghari; Gill, Rajbir K; Shih, Joanna H; Hewitt, Stephen; Jeon, Hyo-Sung; Fukuoka, Junya; Shilo, Konstantin; Shakoori, Abbas; Jen, Jin

    2015-01-01

    Immunohistochemical analysis (IHC) of tissue microarray (TMA) slides enables large sets of tissue samples to be analyzed simultaneously on a single slide. However, manual evaluation of small cores on a TMA slide is time consuming and error prone. We describe a computer aided scoring and analysis (CASA) method to allow facile and reliable scoring of IHC staining using TMA containing 300 non-small cell lung cancer (NSCLC) cases. In the two previous published papers utilizing our TMA slides of lung cancer we examined 18 proteins involved in the chromatin machinery. We developed our study using more proteins of the chromatin complex and several transcription factors that facilitate the chromatin machinery. Then, a total of 78 antibodies were evaluated by CASA to derive a normalized intensity value that correlated with the overall staining status of the targeting protein. The intensity values for TMA cores were then examined for association to clinical variables and predictive significance individually and with other factors. RESULTs: Using our TMA, the intensity of several protein pairs were significantly correlated with an increased risk of death in NSCLC. These included c-Myc with p16, mSin3A with p16 and c-Myc with mSinA. Predictive values of these pairs remained significant when evaluated based on standard IHC scores. Our results demonstrate the usefulness of CASA as a valuable tool for systematic assessment of TMA slides to identify potential predictive biomarkers using a large set of primary human tissues.

  15. Meconium-stained amniotic fluid and hypoglycemia among term newborn infants.

    PubMed

    Maayan-Metzger, Ayala; Leibovitch, Leah; Schushan-Eisen, Irit; Strauss, Tzipora; Kuint, Jacob

    2012-10-01

    To evaluate whether meconium-stained amniotic fluid (MSAF) is a risk factor for neonatal hypoglycemia. Retrospective recording of medical charts of full-term infants born following observation of meconium-stained amniotic fluid to examine glucose levels in the first hours of life. Out of 803 infants of the study group, 68 (8.5%) had glucose levels lower than 47 mg/dl. Most (6.7%) had mild hypoglycemia, and 14 (1.8%) had moderate or severe hypoglycemia (1.4% and 0.4% respectively). No infant developed clinical signs clearly related to hypoglycemia. Low-risk infants born following meconium-stained amniotic fluid are not at increased risk for neonatal hypoglycemia.

  16. Efficacy of testicular sperm chromatin condensation assay using aniline blue-eosin staining in the IVF-ET cycle.

    PubMed

    Park, Yong-Seog; Kim, Myo Kyung; Lee, Sun-Hee; Cho, Jae Won; Song, In Ok; Seo, Ju Tae

    2011-09-01

    This study was performed to evaluate testicular sperm chromatin condensation using aniline blue-eosin (AB-E) staining and its effects on IVF-ET. Chromatin condensation was analyzed using AB-E staining in 27 cases of testicular sperm extraction. There were 19 cases of obstructive azoospermia (OA) and 8 cases of non-obstructive azoospermia (NOA) in IVF-ET. Mature sperm heads were stained red-pink whereas immature sperm heads were stained dark blue. The percentage of sperm chromatin condensation was calculated from the ratio of the number of red-pink sperm to the total number of sperm analyzed. The overall percentages of chromatin condensation in OA and NOA were 31.1±11.2% and 26.3±14.4%, respectively. The fertilization rate was significant higher in OA than NOA (p<0.05); however, the rates of good embryos and clinical pregnancy did not show statistical differences. In OA and NOA, statistical differences were not observed in the rate of chromatin condensation, fertilization, good embryos, and clinical pregnancy between the pregnant group and non-pregnant group. Chromatin condensation is less stable than OA and showed a low fertilization rate in NOA. While there were no significant differences in chromatin condensation results between NOA and OA, we propose that a pattern of decreased chromatin condensation in NOA is one of the factors of low fertilization results requiring further study.

  17. Photoacoustic detection of neovascularities in skin graft

    NASA Astrophysics Data System (ADS)

    Yamazaki, Mutsuo; Sato, Shunichi; Saitoh, Daizo; Ishihara, Miya; Okada, Yoshiaki; Ashida, Hiroshi; Obara, Minoru

    2005-04-01

    We previously proposed a new method for monitoring adhesion of skin graft by measuring photoacoustic (PA) signal originated from the neovascularities. In this study, immunohistochemical staining (IHC) with CD31 antibody was performed for grafted skin tissue to observe neovascularity, and the results were compared with PA signals. We also used a laser Doppler imaging (LDI) to observe blood flow in the grafted skin, and sensitivity of PA measurement and that of LDI were compared. In rat autograft models, PA signals were measured for the grafted skin at postgrafting times of 0-48 h. At 6 h postgrafting, PA signal was observed in the skin depth region of 500-600 mm, while the results of IHC showed that angiogenesis occurred at the depth of about 600 mm. Depths at which PA signal and angiogenesis were observed decreased with postgrafting time. These indicate that the PA signal observed at 6 h postgrafting originated from the neovascularities in the skin graft. Results of LDI showed no blood-originated signal before 48 h postgrafting. These findings suggest that PA measurement is effective in monitoring the adhesion of skin graft in early stage after transplantation.

  18. Propidium iodide staining: a new application in fluorescence microscopy for analysis of cytoarchitecture in adult and developing rodent brain.

    PubMed

    Hezel, Marcus; Ebrahimi, Fahim; Koch, Marco; Dehghani, Faramarz

    2012-10-01

    Immunohistochemical visualization of antigens in specimen has evolved to an indispensable technique in biomedical research for investigations of cell morphology and pathology both in bright field and fluorescence microscopy. While there are couple of staining methods that reveal entire cytoarchitecture in bright field microscopy such as Nissl or hemalaun-eosin, there are still limitations in visualizations of cytoarchitecture in fluorescence microscopy. The present study reports a simple staining method that provides the required illustration of cell allocations and cellular composition in fluorescence microscopy in adult and in developing rodent central nervous system using the fluorophore propidium iodide (PI, 5μg/mL). PI is a well-accepted marker for degenerating cells when applied prior to fixation (pre-fixation PI staining). Here, PI was added to the sections after the fixation (post-fixation PI staining). This revised labeling procedure led to similar cytoarchitectural staining patterns in fluorescence microscopy as observed with hemalaun in bright field microscopy. This finding was proven in organotypic hippocampal slice cultures (OHSC) and brain sections obtained from different postnatal developmental stages. Excitotoxically lesioned OHSC subjected to pre-fixation PI staining merely showed brightly labeled condensed nuclei of degenerating neurons. In contrast, post-fixation PI staining additionally revealed extensive labeling of neuronal cell bodies and glial cells within the OHSC, thus allowing visualization of stratification of neuronal layers and cell morphology. Furthermore, post-fixation PI staining was combined with NeuN, calbindin, calretinin, glial fibrillary acidic protein or Griffonia simplicifolia isolectin B4 (IB(4)) in post natal (p1 and p9) and adult rats. In early post-natal brain sections almost all mentioned cellular markers led to an incomplete staining of the native cell organization and resulted in an inaccurate estimation of cell

  19. Target-oriented imaging of hydraulic fractures by applying the staining algorithm for downhole microseismic migration

    NASA Astrophysics Data System (ADS)

    Lin, Ye; Zhang, Haijiang; Jia, Xiaofeng

    2018-03-01

    For microseismic monitoring of hydraulic fracturing, microseismic migration can be used to image the fracture network with scattered microseismic waves. Compared with conventional microseismic location-based fracture characterization methods, microseismic migration can better constrain the stimulated reservoir volume regardless of the completeness of detected and located microseismic sources. However, the imaging results from microseismic migration may suffer from the contamination of other structures and thus the target fracture zones may not be illuminated properly. To solve this issue, in this study we propose a target-oriented staining algorithm for microseismic reverse-time migration. In the staining algorithm, the target area is first stained by constructing an imaginary velocity field and then a synchronized source wavefield only concerning the target structure is produced. As a result, a synchronized image from imaging with the synchronized source wavefield mainly contains the target structures. Synthetic tests based on a downhole microseismic monitoring system show that the target-oriented microseismic reverse-time migration method improves the illumination of target areas.

  20. Quantitative proteome analysis of barley seeds using ruthenium(II)-tris-(bathophenanthroline-disulphonate) staining.

    PubMed

    Witzel, Katja; Surabhi, Giridara-Kumar; Jyothsnakumari, Gottimukkala; Sudhakar, Chinta; Matros, Andrea; Mock, Hans-Peter

    2007-04-01

    This paper describes the application of the recently introduced fluorescence stain Ruthenium(II)-tris-(bathophenanthroline-disulphonate) (RuBP) on a comparative proteome analysis of two phenotypically different barley lines. We carried out an analysis of protein patterns from 2-D gels of the parental lines of the Oregon Wolfe Barley mapping population DOM and REC and stained with either the conventional colloidal Coomassie Brilliant Blue (cCBB) or with the novel RuBP solution. We wished to experimentally verify the usefulness of such a stain in evaluating the complex pattern of a seed proteome, in comparison to the previously used cCBB staining technique. To validate the efficiency of visualization by both stains, we first compared the overall number of detected protein spots. On average, 790 spots were visible by cCBB staining and 1200 spots by RuBP staining. Then, the intensity of a set of spots was assessed, and changes in relative abundance were determined using image analysis software. As expected, staining with RuBP performed better in quantitation in terms of sensitivity and dynamic range. Furthermore, spots from a cultivar-specific region in the protein map were chosen for identification to asses the gain of biological information due to the staining procedure. From this particular region, eight spots were visualized exclusively by RuBP and identification was successful for all spots, proving the ability to identify even very low abundant proteins. Performance in MS analysis was comparable for both protein stains. Proteins were identified by MALDI-TOF MS peptide mass fingerprinting. This approach was not successful for all spots, due to the restricted entry number for barley in the database. Therefore, we subsequently used LC-ESI-Q-TOF MS/MS and de novo sequencing for identification. Because only an insufficient number of proteins from barley is annotated, an EST-based identification strategy was chosen for our experiment. We wished to test whether under

  1. Analytic Validation of Immunohistochemistry Assays: New Benchmark Data From a Survey of 1085 Laboratories.

    PubMed

    Stuart, Lauren N; Volmar, Keith E; Nowak, Jan A; Fatheree, Lisa A; Souers, Rhona J; Fitzgibbons, Patrick L; Goldsmith, Jeffrey D; Astles, J Rex; Nakhleh, Raouf E

    2017-09-01

    - A cooperative agreement between the College of American Pathologists (CAP) and the United States Centers for Disease Control and Prevention was undertaken to measure laboratories' awareness and implementation of an evidence-based laboratory practice guideline (LPG) on immunohistochemical (IHC) validation practices published in 2014. - To establish new benchmark data on IHC laboratory practices. - A 2015 survey on IHC assay validation practices was sent to laboratories subscribed to specific CAP proficiency testing programs and to additional nonsubscribing laboratories that perform IHC testing. Specific questions were designed to capture laboratory practices not addressed in a 2010 survey. - The analysis was based on responses from 1085 laboratories that perform IHC staining. Ninety-six percent (809 of 844) always documented validation of IHC assays. Sixty percent (648 of 1078) had separate procedures for predictive and nonpredictive markers, 42.7% (220 of 515) had procedures for laboratory-developed tests, 50% (349 of 697) had procedures for testing cytologic specimens, and 46.2% (363 of 785) had procedures for testing decalcified specimens. Minimum case numbers were specified by 85.9% (720 of 838) of laboratories for nonpredictive markers and 76% (584 of 768) for predictive markers. Median concordance requirements were 95% for both types. For initial validation, 75.4% (538 of 714) of laboratories adopted the 20-case minimum for nonpredictive markers and 45.9% (266 of 579) adopted the 40-case minimum for predictive markers as outlined in the 2014 LPG. The most common method for validation was correlation with morphology and expected results. Laboratories also reported which assay changes necessitated revalidation and their minimum case requirements. - Benchmark data on current IHC validation practices and procedures may help laboratories understand the issues and influence further refinement of LPG recommendations.

  2. Basal cell carcinoma: CD56 and cytokeratin 5/6 staining patterns in the differential diagnosis with Merkel cell carcinoma.

    PubMed

    Panse, Gauri; McNiff, Jennifer M; Ko, Christine J

    2017-06-01

    Basal cell carcinoma (BCC) can resemble Merkel cell carcinoma (MCC) on histopathological examination and while CK20 is a useful marker in this differential, it is occasionally negative in MCC. CD56, a sensitive marker of neuroendocrine differentiation, is sometimes used to identify MCC, but has been reportedly variably positive in BCC as well. In contrast, CK5/6 consistently labels BCC but is not expressed in neuroendocrine tumors. We evaluated 20 cases of BCC for the pattern of CD56 and cytokeratin 5/6 (CK5/6) staining, hypothesizing that these 2 stains could differentiate BCC from MCC in difficult cases. Seventeen cases of MCC previously stained with CD56 were also examined. All BCCs showed patchy expression of CD56 except for 2 cases, which showed staining of greater than 70% of tumor. CK5/6 was diffusely positive in all cases of BCC. Fifteen of 17 MCCs were diffusely positive for CD56. The difference in the pattern of CD56 expression between MCC and BCC (diffuse vs patchy, respectively) was statistically significant (P < .05). BCC typically shows patchy CD56 expression and diffuse CK5/6 positivity. These 2 markers can be used to distinguish between BCC and MCC in challenging cases. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Immunoperoxidase staining for identification of Aspergillus species in routinely processed tissue sections.

    PubMed Central

    Verweij, P E; Smedts, F; Poot, T; Bult, P; Hoogkamp-Korstanje, J A; Meis, J F

    1996-01-01

    AIMS: To evaluate the performance of an immunoperoxidase stain using the monoclonal antibody EB-A1 to detect Aspergillus species in formalin fixed, paraffin wax embedded tissue. METHODS: The monoclonal antibody EB-A1 directed against galactomannan was used to detect Aspergillus species in 23 patients with suspected or confirmed invasive aspergillosis. Immunostaining was performed on formalin fixed, paraffin wax embedded tissue using the streptavidin-biotin method and compared with conventional haematoxylin and eosin, periodic acid-Schiff, and Gomori-Grocott stains. Results of immunostaining were semiquantitatively analysed with regard to both intensity of staining and number of positively staining micro-organisms. Tissue sections from 16 patients with confirmed invasive mycoses due to Candida species, Apophysomyces elegans, Rhizopus oryzae, Pseudallescheria boydii and Histoplasma capsulatum were used as controls. RESULTS: In 19 (83%) of 23 cases invasive aspergillosis was confirmed by both histological examination and culture (18 Aspergillus fumigatus and one A flavus). Immunoperoxidase stains were positive in 17 (89%) of 19 cases including one case of disseminated infection due to A flavus. Furthermore, the immunoperoxidase stain was positive in a culture negative tissue section with histological evidence of mycelial development, indicating the presence of Aspergillus species. Some cross-reactivity was observed with the highly related fungus P boydii, although the number of mycelial elements that stained was low. CONCLUSIONS: Immunoperoxidase staining using the monoclonal antibody EB-A1 performs well on routinely processed tissue sections and permits detection and generic identification of Aspergillus species, although it was no better than conventional histopathology in identifying the presence of an infection. An additional advantage is that the immunostain may help to provide an aetiological diagnosis when cultures remain negative. Images PMID:8943743

  4. Simultaneous Fluorescent Gram Staining and Activity Assessment of Activated Sludge Bacteria

    PubMed Central

    Forster, Scott; Snape, Jason R.; Lappin-Scott, Hilary M.; Porter, Jonathan

    2002-01-01

    Wastewater treatment is one of the most important commercial biotechnological processes, and yet the component bacterial populations and their associated metabolic activities are poorly understood. The novel fluorescent dye hexidium iodide allows assessment of Gram status by differential absorption through bacterial cell walls. Differentiation between gram-positive and gram-negative wastewater bacteria was achieved after flow cytometric analysis. This study shows that the relative proportions of gram-positive and gram-negative bacterial cells identified by traditional microscopy and hexidium iodide staining were not significantly different. Dual staining of cells for Gram status and activity proved effective in analyzing mixtures of cultured bacteria and wastewater populations. Levels of highly active organisms at two wastewater treatment plants, both gram positive and gram negative, ranged from 1.5% in activated sludge flocs to 16% in the activated sludge fluid. Gram-positive organisms comprised <5% of the total bacterial numbers but accounted for 19 and 55% of the highly active organisms within flocs at the two plants. Assessment of Gram status and activity within activated sludge samples over a 4-day period showed significant differences over time. This method provides a rapid, quantitative measure of Gram status linked with in situ activity within wastewater systems. PMID:12324319

  5. Simultaneous fluorescent gram staining and activity assessment of activated sludge bacteria.

    PubMed

    Forster, Scott; Snape, Jason R; Lappin-Scott, Hilary M; Porter, Jonathan

    2002-10-01

    Wastewater treatment is one of the most important commercial biotechnological processes, and yet the component bacterial populations and their associated metabolic activities are poorly understood. The novel fluorescent dye hexidium iodide allows assessment of Gram status by differential absorption through bacterial cell walls. Differentiation between gram-positive and gram-negative wastewater bacteria was achieved after flow cytometric analysis. This study shows that the relative proportions of gram-positive and gram-negative bacterial cells identified by traditional microscopy and hexidium iodide staining were not significantly different. Dual staining of cells for Gram status and activity proved effective in analyzing mixtures of cultured bacteria and wastewater populations. Levels of highly active organisms at two wastewater treatment plants, both gram positive and gram negative, ranged from 1.5% in activated sludge flocs to 16% in the activated sludge fluid. Gram-positive organisms comprised <5% of the total bacterial numbers but accounted for 19 and 55% of the highly active organisms within flocs at the two plants. Assessment of Gram status and activity within activated sludge samples over a 4-day period showed significant differences over time. This method provides a rapid, quantitative measure of Gram status linked with in situ activity within wastewater systems.

  6. Hierarchical patch-based co-registration of differently stained histopathology slides

    NASA Astrophysics Data System (ADS)

    Yigitsoy, Mehmet; Schmidt, Günter

    2017-03-01

    Over the past decades, digital pathology has emerged as an alternative way of looking at the tissue at subcellular level. It enables multiplexed analysis of different cell types at micron level. Information about cell types can be extracted by staining sections of a tissue block using different markers. However, robust fusion of structural and functional information from different stains is necessary for reproducible multiplexed analysis. Such a fusion can be obtained via image co-registration by establishing spatial correspondences between tissue sections. Spatial correspondences can then be used to transfer various statistics about cell types between sections. However, the multi-modal nature of images and sparse distribution of interesting cell types pose several challenges for the registration of differently stained tissue sections. In this work, we propose a co-registration framework that efficiently addresses such challenges. We present a hierarchical patch-based registration of intensity normalized tissue sections. Preliminary experiments demonstrate the potential of the proposed technique for the fusion of multi-modal information from differently stained digital histopathology sections.

  7. Toothpastes containing abrasive and chemical whitening agents: efficacy in reducing extrinsic dental staining.

    PubMed

    Soares, Cristina Neves Girao Salgado; Amaral, Flavia Lucisano Botelho do; Mesquita, Marcelo Ferraz; Franca, Fabiana Mantovani Gomes; Basting, Roberta Tarkany; Turssi, Cecilia Pedroso

    2015-01-01

    This in vitro study evaluated the efficacy of toothpastes containing abrasive and chemical whitening agents in reducing the extrinsic discoloration of dental enamel. Sixty slabs of dentin from human teeth were sealed so that only the enamel surface was exposed. The enamel surfaces were photographed for initial color assessment. Staining was performed by immersing the dental slabs in 0.2% chlorhexidine solution for 2 minutes and then in black tea for 60 minutes. This process was repeated 15 times. Photographs were taken at the end of the staining process, and the slabs were divided into 5 groups (n = 12), 3 to be brushed with toothpastes containing chemical whitening agents (2 containing phosphate salts and 1 containing phosphate salts plus hydrogen peroxide) and 2 to represent control groups (ordinary/nonwhitening toothpaste and distilled water). The dental slabs were subjected to mechanical toothbrushing with toothpaste slurry or distilled water, according to each group's specifications. After brushing, more photographs were taken for color analysis. The results showed a significant reduction in luminosity after the staining process in addition to an increase in the colors red and yellow (P < 0.001). After brushing, there was a significant increase in luminosity and a reduction in both red and yellow (P < 0.001). However, there was no observed difference between the changes in color values in dental enamel slabs brushed with whitening toothpastes and the changes found in slabs brushed with ordinary toothpaste. The whitening toothpastes did not outperform an ordinary toothpaste in the removal of extrinsic staining.

  8. Automated robust registration of grossly misregistered whole-slide images with varying stains

    NASA Astrophysics Data System (ADS)

    Litjens, G.; Safferling, K.; Grabe, N.

    2016-03-01

    Cancer diagnosis and pharmaceutical research increasingly depend on the accurate quantification of cancer biomarkers. Identification of biomarkers is usually performed through immunohistochemical staining of cancer sections on glass slides. However, combination of multiple biomarkers from a wide variety of immunohistochemically stained slides is a tedious process in traditional histopathology due to the switching of glass slides and re-identification of regions of interest by pathologists. Digital pathology now allows us to apply image registration algorithms to digitized whole-slides to align the differing immunohistochemical stains automatically. However, registration algorithms need to be robust to changes in color due to differing stains and severe changes in tissue content between slides. In this work we developed a robust registration methodology to allow for fast coarse alignment of multiple immunohistochemical stains to the base hematyoxylin and eosin stained image. We applied HSD color model conversion to obtain a less stain color dependent representation of the whole-slide images. Subsequently, optical density thresholding and connected component analysis were used to identify the relevant regions for registration. Template matching using normalized mutual information was applied to provide initial translation and rotation parameters, after which a cost function-driven affine registration was performed. The algorithm was validated using 40 slides from 10 prostate cancer patients, with landmark registration error as a metric. Median landmark registration error was around 180 microns, which indicates performance is adequate for practical application. None of the registrations failed, indicating the robustness of the algorithm.

  9. A new procedure for fast soft staining of BN-PAGEs on photosynthetic complexes.

    PubMed

    Farci, Domenica; Kirkpatrick, Joanna; Piano, Dario

    2017-02-01

    We report a fast and sensitive procedure for blue native PAGE staining, in which the conventional staining step with CBB is avoided. After running, a short exposure to a mix of polar protic solvents (ethanol and acetic acid) leads to a fast and selective removal of the dye from the migration front and a specific binding to the protein bands, while the rest undergo a selective and complete background removal, leading to an intense contrast. This single-step staining-destaining technique is useful in protein samples that bind colored cofactors such as photosystems, which can be selectively discerned by their characteristic green color. After the staining of such samples, the green color persists, while the other unpigmented protein complexes and the molecular standard remain CBB stained, creating a useful reference system for the assignment of the bands. The advantages and chemical basis of this staining procedure are discussed. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Mass spectrometry-compatible silver staining of histones resolved on acetic acid-urea-Triton PAGE.

    PubMed

    Pramod, Khare Satyajeet; Bharat, Khade; Sanjay, Gupta

    2009-05-01

    Acetic acid-Urea-Triton (AUT) PAGE is commonly used method to separate histone variants and their post-translationally modified forms. Coomassie staining is the preferred method for protein visualization; however, its sensitivity is less than that of silver staining. Though silver staining of histones in AUT-PAGE has been reported, the method is time-consuming, dependent on prior staining by Amido black and has not been reported suitable for mass spectrometry. Here, we propose 'SDS-Silver' method for rapid, sensitive and mass spectrometry-compatible staining of histones resolved on AUT-PAGE.

  11. [Regulatory effect and mechanism of RNA binding motif protein 38 on the expression of progesterone receptor in human breast cancer ZR-75-1 cells].

    PubMed

    Lou, P P; Li, C L; Xia, T S; Shi, L; Wu, J; Zhou, X J; Wang, Y; Ding, Q

    2016-06-23

    To investigate the regulatory mechanism of RNA binding motif protein 38 (RNPC1) on the expression of progesterone receptor (PR) in breast cancer cell line ZR-75-1. Lentiviral vector was used to induce overexpression of RNPC1 in ZR-75-1 cells. qRT-PCR and Western blot were used to assess the regulatory effect of RNPC1 on PR expression. Actinomycin was used to detect the regulatory mechanism involved. Immunohistochemical (IHC) staining was used to determine the protein expression of RNPC1 and PR in 80 breast cancer tissues. IHC staining showed that the expression of RNPC1 was significantly higher in the PR positive breast cancer tissues than that in the PR negative breast cancer tissues (P<0.05). The qRT-PCR results showed that overexpression of RNPC1 in ZR-75-1 cells significantly upregulated the mRNA level of PR (1.764±0.028 vs. 1.001±0.037, P<0.01), whereas knockdown of RNPC1 did the opposite (0.579± 0.007 vs. 1.000±0.002, P<0.01). The Western blot results also showed that overexpression of RNPC1 up-regulated PR levels, while knockdown of RNPC1 resulted in down-regulation of PR levels in the ZR-75-1 cells.The actinomycin assay showed that overexpression of RNPC1 increased the mRNA stability of PR. The half-life of PR mRNA was increased from 4.0 h to 6.5 h. Knockdown of RNPC1 decreased the mRNA stability of PR and the half-life of PR transcript was decreased from 4.1 h to 3.0 h. RNPC1 plays a crucial role in regulating the expression of PR in breast cancer ZR-75-1 cells.

  12. Effectiveness of a new dentifrice with baking soda and peroxide in removing extrinsic stain and whitening teeth.

    PubMed

    Ghassemi, A; Hooper, W; Vorwerk, L; Domke, T; DeSciscio, P; Nathoo, S

    2012-01-01

    The primary purpose of this randomized, controlled, six-week clinical trial was to determine the effectiveness and safety of a new whitening dentifrice in removing extrinsic tooth stain and whitening teeth. An additional two-week exploratory study was conducted to determine whether the whitening or stain-prevention activity of the dentifrice would persist following cessation of use. In the first study (Phase I), one-hundred and forty-six qualifying subjects were randomly assigned to either a sodium bicarbonate whitening dentifrice group (Arm & Hammer Advance White Extreme Whitening Baking Soda and Peroxide Toothpaste) or a silica-based negative control dentifrice group, and brushed twice daily with their assigned dentifrice for six weeks. Tooth shade on the labial surfaces of the eight incisors was assessed using a Vita Classic shade guide, and extrinsic tooth stain was scored using a Modified Lobene Stain Index (MLSI) at baseline, week 4, and week 6. In Phase II (after the week 6 examination), volunteers from the Arm & Hammer whitening dentifrice group were randomly assigned to continue using the whitening dentifrice or to use the negative control dentifrice twice daily for two weeks. The six-week shade and stain index scores served as the baseline for this exploratory phase and were rescored after two weeks. The whitening dentifrice group had statistically significant (p < 0.0001) mean shade score reductions of 1.82 and 2.57 from baseline to weeks 4 and 6, respectively. For the same periods, the negative control dentifrice group was virtually unchanged from baseline. For tooth stain, the MLSI total mean scores for the whitening dentifrice group showed statistically significant (p < 0.0001) decreases from baseline of 1.42 (41.6%) and 2.11 (61.6%) at weeks 4 and 6, respectively. In contrast, the negative control dentifrice group had a MLSI reduction of 0.07 at week 4 and a 0.06 increase at week 6. Between-group analyses using baseline-adjusted ANCOVA showed the

  13. Efficacy of propidium iodide and FUN-1 stains for assessing viability in basidiospores of Rhizopogon roseolus.

    PubMed

    Fernández-Miranda, Elena; Majada, Juan; Casares, Abelardo

    2017-01-01

    The use of spores in applications of ectomycorrhizal fungi requires information regarding spore viability and germination, especially in genera such as Rhizopogon with high rates of spore dormancy. The authors developed a protocol to assess spore viability of Rhizopogon roseolus using four vital stains to quantify spore viability and germination and to optimize storage procedures. They showed that propidium iodide is an excellent stain for quantifying nonviable spores. Observing red fluorescent intravacuolar structures following staining with 2-chloro-4-(2,3-dihydro-3-methyl-(benzo-1,3-thiazol-2-yl)-methylidene)-1-phenylquinolinium iodide (FUN-1) can help identify viable spores that are activated. At 6 mo and 1 y, the spores kept in a water suspension survived better than those left within intact, dry gasterocarps. Our work highlights the importance of temperature, nutrients, and vitamins for maturation and germination of spores of R. roseolus during 1 y of storage.

  14. Macrodissection prior to closed system RT-qPCR is not necessary for estrogen receptor and HER2 concordance with IHC/FISH in breast cancer.

    PubMed

    Gupta, Swati; Mani, Navin R; Carvajal-Hausdorf, Daniel E; Bossuyt, Veerle; Ho, Kenneth; Weidler, Jodi; Wong, Wendy; Rhees, Brian; Bates, Michael; Rimm, David L

    2018-06-01

    An on-demand, closed RT-qPCR, the GeneXpert (GX) system, has the potential to provide biomarker information in low-resourced settings and elsewhere. We used this system with a research use only version of the Breast Cancer STRAT4 cartridge that measures the mRNA expression levels of ERBB2, ESR1, PGR, and MKi67. Here we evaluated the impact of non-macrodissected (non m-d) versus macrodissected (m-d) samples using STRAT4 on formalin-fixed, paraffin-embedded (FFPE) core needle biopsies. Two cohorts were assessed: (1) 60 FFPE infiltrating ductal carcinoma (IDCA) cases and (2) 20 FFPE IDCA cases with ductal carcinoma in situ (DCIS) with a range of HER2 expression as determined by clinical immunohistochemistry and fluorescence in situ hybridization (IHC/FISH). We observed about half of the core needle biopsy area as invasive tumor in both IDCA (mean = 51.5%) and IDCA with DCIS (mean = 53.5%) cohorts, but also found the mRNA levels were independent of tumor area. We found excellent agreement of the mRNA transcript level between the paired samples, m-d versus non m-d, for ERBB2, ESR1, PGR, and MKi67 for both the IDCA and IDCA with DCIS cohorts. No significant difference (P > 0.99) was observed when we compared the mRNA transcript level between the paired samples m-d versus non m-d. In addition, we noted a significant concordance (P < 0.001) between RT-qPCR and IHC/FISH for HER2-positivity, ER-positivity, and PR-positivity, independent of specimen dissection. These data suggest that mRNA expression for ERBB2, ESR, and PGR is sufficiently low in surrounding tissue cells such that macrodissection is not required for assessment of key breast cancer mRNA markers and is independent of the amount of input tumor. This approach may be valuable in settings lacking pathology expertise or using specimen types, such as fine-needle aspirates, where it may be challenging to separate non-tumor from tumor tissue.

  15. [Expression of neuropeptide Y and long leptin receptor in gastrointestinal tract of giant panda].

    PubMed

    Luo, Qihui; Tang, Xiuying; Chen, Zhengli; Wang, Kaiyu; Wang, Chengdong; Li, Desheng; Li, Caiwu

    2015-08-01

    To study the expression and distribution of neuropeptide Y (NPY) and long leptin receptor (OB-Rb) in the gastrointestinal tract of giant panda, samples of three animals were collected from the key laboratory for reproduction and conservation genetics of endangered wildlife of Sichuan province, China conservation and research center for the giant panda. Paraffin sections of giant panda gastrointestinal tissue samples were observed using hematoxylin-eosin staining (HE) and strept actividin-biotin complex immunohistochemical staining (IHC). The results show that the intestinal histology of three pandas was normal and no pathological changes, and there were rich single-cell and multi-cell mucous glands, long intestinal villi and thick muscularis mucosa and muscle layer. Positive cells expressing NPY and OB-Rb were widely detected in the gastrointestinal tract by IHC methods. NPY positive nerve fibers and neuronal cell were widely distributed in submucosal plexus and myenteric plexus, especially in the former. They were arranged beaded or point-like shape. NPY positive cells were observed in the shape of ellipse and polygon and mainly located in the mucous layer and intestinal glands. OB-Rb positive cells were mainly distributed in the mucous layer and the laminae propria, especially the latter. These results confirmed that NPY and OB-Rb are widely distributed in the gut of the giant panda, which provide strong reference for the research between growth and development, digestion and absorption, and immune function.

  16. 57. DETAIL OF EAST END OF CHANCEL SHOWING BISHOP'S CHAIR, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    57. DETAIL OF EAST END OF CHANCEL SHOWING BISHOP'S CHAIR, ALTAR, AND STAINED GLASS WINDOWS; NOTE MINTON TILE MEDALLIONS ON FLOOR - Church of the Holy Cross, State Route 261, Stateburg, Sumter County, SC

  17. Quantitative determination of superoxide in plant leaves using a modified NBT staining method.

    PubMed

    Bournonville, Carlos F Grellet; Díaz-Ricci, Juan Carlos

    2011-01-01

    In plants, the ROS (reactive oxygen species) level is tightly regulated because their accumulation produces irreversible damage leading to cell death. However, ROS accumulation plays a key role in plant signaling under biotic or abiotic stress. Although various methods were reported to evaluate ROS accumulation, they are restricted to model plants or provide only qualitative information. Develop a simple method to quantify superoxide radicals produced in plant tissues, based on the selective extraction of the formazan produced after nitroblue tetrazolium (NBT) reduction in histochemical staining. Plant leaves were stained with a standard NBT method and the formazan precipitated in tissues was selectively extracted using chloroform. The organic phase was dried and formazan residue dissolved in dimethylsulfoxide-potassium hydroxide and quantified by spectrophotometry. The method was tested in strawberry plant leaves under different stressing conditions. Formazan extracted from leaves subjected to stress conditions showed similar absorption spectra to those obtained from standard solutions using pure formazan. Calibration curves showed a linear relationship between absorbance and formazan amounts, within the range 0.5-8 µg. Outcomes suggested that formazan was retained in the solid residue of leaf tissues. This protocol allowed us to quantify superoxide radicals produced under different stress conditions. Chloroform allowed a selective formazan extraction and removal of potential endogenous, exogenous or procedural artefacts that may interfere with the quantitative determination. This protocol can be used to quantify the superoxide produced in plant tissues using any traditional qualitative NBT histochemical staining method. Copyright © 2011 John Wiley & Sons, Ltd.

  18. Comparison of selective staining of fungi in paraffin sections by light microscopy, SEM and BEI

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berman, E.L.; Laudate, A.; Carter, H.W.

    Paraffin-embedded sections from human tissues with fungi or organisms classified with fungi were studied by light microscopy (LM), scanning electron microscopy (SEM), and the backscatter electron imaging (BEI) mode of the SEM. The fungal organisms selected for study were those familiar to the pathologist on the basis of their appearance in paraffin-embedded material stained with the Gomori-Grocott Chromic Acid Methenamine Silver Stain (GMS). The organisms were Actinomyces, Rhizopus, Cryptococcus, Histoplasma capsulatum, and Coccidia imitis. Sections were stained with the GMS Stain and/or the Becker modification of the GMS Stain (BGMS) and examined in the secondary electron imaging mode (SEI) andmore » BEI mode with an annular backscatter electron detector. This silver staining technique accentuated the wall of fungal organisms, in the backscatter mode. Depending on the fungal organism and type of silver stain employed, the GMS seemed the preferable stain. The advantages of SEM over LM were greater depth of focus and potential range of magnifications. BEI may also be used in conjunction with LM stain for microorganisms to establish their presence.« less

  19. Effect of fabric mounting method and backing material on bloodstain patterns of drip stains on textiles.

    PubMed

    Chang, J Y M; Michielsen, S

    2016-05-01

    Textiles may provide valuable bloodstain evidence to help piece together events or activities at violent crime scenes. However, in spite of over 75 years of research, there are still difficulties encountered in many cases in the interpretation and identification of bloodstains on textiles. In this study, we dripped porcine blood onto three types of fabric (plain woven, single jersey knit, and denim) that are supported in four different ways (hard, taut, loose, and semi-hard, i.e., fabric laid on denim). These four mounting methods represent different ways in which a textile may be present when blood from a violent act lands on it. This study investigates how the fabric mounting method and backing material affect the appearance of drip stains on textiles. We found that bloodstain patterns formed on fabric lying flat on a hard surface were very different from when the same fabric was suspended loosely. We also found that bloodstains formed on the technical back of single jersey knit were vastly different from those on the technical face. Interestingly, some drip stains showed blood passing through the textile and leaving a stain behind it that resembled insect stains. By observing, recording, and describing how a blood stained textile is found or presented at the scene, the analyst may be able to better understand bloodstains and bloodstain patterns on textiles, which could be useful to confirm or refute a witness's account of how blood came to be where it was found after a bloodshed event.

  20. 19 CFR 10.52 - Painted, colored or stained glass windows for religious institutions.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 19 Customs Duties 1 2011-04-01 2011-04-01 false Painted, colored or stained glass windows for.... General Provisions Works of Art § 10.52 Painted, colored or stained glass windows for religious institutions. When painted, colored, or stained glass windows or parts thereof, are claimed free of duty under...