Sample records for implant long-term deleterious

  1. Short-Term and Long-Term Effects of Orthopedic Biodegradable Implants

    PubMed Central

    Amini, Ami R.; Wallace, James S.; Nukavarapu, Syam P.

    2012-01-01

    Presently, orthopedic and oral/maxillofacial implants represent a combined $2.8 billion market, a figure expected to experience significant and continued growth. Although traditional permanent implants have been proved clinically efficacious, they are also associated with several drawbacks, including secondary revision and removal surgeries. Non-permanent, biodegradable implants offer a promising alternative for patients, as they provide temporary support and degrade at a rate matching tissue formation, and thus, eliminate the need for secondary surgeries. These implants have been in clinical use for nearly 25 years, competing directly with, or maybe even exceeding, the performance of permanent implants. The initial implantation of biodegradable materials, as with permanent materials, mounts an acute host inflammatory response. Over time, the implant degradation profile and possible degradation product toxicity mediate long-term biodegradable implant-induced inflammation. However, unlike permanent implants, this inflammation is likely to cease once the material disappears. Implant-mediated inflammation is a critical determinant for implant success. Thus, for the development of a proactive biodegradable implant that has the ability to promote optimal bone regeneration and minimal detrimental inflammation, a thorough understanding of short- and long-term inflammatory events is required. Here, we discuss an array of biodegradable orthopedic implants, their associated short- and long- term inflammatory effects, and methods to mediate these inflammatory events. PMID:22043969

  2. Long-term hearing result using Kurz titanium ossicular implants.

    PubMed

    Hess-Erga, Jeanette; Møller, Per; Vassbotn, Flemming Slinning

    2013-05-01

    Titanium implants in middle ear surgery were introduced in the late 90s and are now frequently used in middle ear surgery. However, long-term studies of patient outcome are few and have only been published in subgroups of patients. We report the long-term effect of titanium middle ear implants for ossicular reconstruction in chronic ear disease investigated in a Norwegian tertiary otological referral centre. Retrospective chart reviews were performed for procedures involving 76 titanium implants between 2000 and 2007. All patients who underwent surgery using the Kurz Vario titanium implant were included in the study. Audiological parameters using four frequencies, 0.5, 1, 2, and 3 kHz, according to AAO-HNS guidelines, was assessed pre and postoperatively. Otosurgical procedures, complications, revisions, and extrusion rates were analyzed. The study had no dropouts. The partial ossicular replacement prosthesis (PORP) was used in 44 procedures and the total ossicular replacement prosthesis (TORP) in 32 procedures, respectively. Mean follow-up was 5.2 years (62 months). The ossiculoplasties were performed as staging procedures or in combination with other chronic ear surgery. The same surgeon performed all the procedures. A postoperative air-bone gap of ≤ 20 dB was obtained in 74 % of the patients, 82 % for the Bell (PORP) prosthesis, and 63 % for the Arial (TORP) prosthesis. The extrusion rate was 5 %. We conclude that titanium ossicular implants give stable and excellent long-term hearing results.

  3. Long-term efficacy of biomodeled polymethyl methacrylate implants for orbitofacial defects.

    PubMed

    Groth, Michael J; Bhatnagar, Aparna; Clearihue, William J; Goldberg, Robert A; Douglas, Raymond S

    2006-01-01

    To report the long-term efficacy of custom polymethyl methacrylate implants using high-resolution computed tomographic modeling in the reconstruction of complex orbitofacial defects secondary to trauma. Nine patients with complex orbitofacial bone defects after trauma were evaluated for this retrospective, nonrandomized, noncomparative study. All the patients underwent reconstruction using custom, heat-cured polymethyl methacrylate implants. Patients were followed up postoperatively and evaluated for complications. Nine consecutive patients (5 men and 4 women) aged 28 to 63 years who underwent surgical reconstruction using prefabricated, heat-cured polymethyl methacrylate implants were included in the study. The interval between injury and presentation ranged from 1 month to 40 years. There were no significant complications, including infection, extrusion, or displacement of the implant. In all of the patients, wound healing was uneventful, with antibiotic drugs administered perioperatively. Mean follow-up was 4.3 years from the first visit (range, 6 months to 10 years). Computed tomographic biomodeled, prefabricated, heat-cured polymethyl methacrylate implants are well tolerated in the long term. Their advantages include customized design, long-term biocompatibility, and excellent aesthetic results.

  4. Does the Implantation Technique for Totally Implantable Venous Access Ports (TIVAPs) Influence Long-Term Outcome?

    PubMed

    Biacchi, Daniele; Sammartino, Paolo; Sibio, Simone; Accarpio, Fabio; Cardi, Maurizio; Sapienza, Paolo; De Cesare, Alessandro; Atta, Joseph Maher Fouad; Impagnatiello, Alessio; Di Giorgio, Angelo

    2016-02-01

    Totally implantable venous access ports (TIVAP) are eventually explanted for various reasons, related or unrelated to the implantation technique used. Having more information on long-term explantation would help improve placement techniques. From a series of 1572 cancer patients who had TIVAPs implanted in our center with the cutdown technique or Seldinger technique, we studied the 542 patients who returned to us to have their TIVAP explanted after 70 days or more. As outcome measures we distinguished between TIVAPs explanted for long-term complications (infection, catheter-, reservoir-, and patient-related complications) and TIVAPs no longer needed. Univariate and multivariate analyses were run to investigate the reasons for explantation and their possible correlation with implantation techniques. The most common reason for explantation was infection (47.6 %), followed by catheter-related (20.8 %), patient-related (14.7 %), and reservoir-related complications (4.7 %). In the remaining 12.2 % of cases, the TIVAP was explanted complication free after the planned treatments ended. Infection correlated closely with longer TIVAP use. Univariate and multivariate analyses identified the Seldinger technique as a major risk factor for venous thrombosis and catheter dislocation. The need for long-term TIVAP explantation in about one-third of cancer patients is related to the implantation techniques used.

  5. Long-Term Safety of Textured and Smooth Breast Implants.

    PubMed

    Calobrace, M Bradley; Schwartz, Michael R; Zeidler, Kamakshi R; Pittman, Troy A; Cohen, Robert; Stevens, W Grant

    2017-12-13

    In this review, the authors provide a 20-year review and comparison of implant options and describe the evolution of breast implant surface textures; compare available implant surfaces; present long-term safety data from the 10-year US-based Core clinical studies; list the key benefits and risks associated with smooth and textured implants; and provide perspectives on breast implant-associated anaplastic large cell lymphoma (BIA-ALCL). The authors explore the key benefits and risks associated with all available devices so that optimal and safe patient outcomes can be achieved. © 2017 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

  6. Intricate Assessment and Evaluation of Effect of Bruxism on Long-term Survival and Failure of Dental Implants: A Comparative Study.

    PubMed

    Yadav, Kajal; Nagpal, Abhishek; Agarwal, S K; Kochhar, Aarti

    2016-08-01

    affected by bruxism. Special attention is required in such patients while doing treatment planning. For the long-term clinical success and survival of dental implants in patients, special emphasis should be given on the patient's deleterious oral habits, such as bruxism as in long run, they influence the stability of dental implants.

  7. Dental implant status of patients receiving long-term nursing care in Japan.

    PubMed

    Kimura, Toru; Wada, Masahiro; Suganami, Toru; Miwa, Shunta; Hagiwara, Yoshiyuki; Maeda, Yoshiobu

    2015-01-01

    The increase in implant patients is expected to give rise to a new problem: the changing general health status of those who have had implants placed. The aim of this present study was to find out the needs of and proper measures for elderly implant patients in long-term care facilities. A questionnaire was sent by mail to 1,591 long-term care health facilities, daycare services for people with dementia, and private nursing homes for the elderly in the Osaka area, which is in the middle area of Japan, in order to extract patients with cerebrovascular disease or dementia who were possibly at risk of inadequate oral self-care, as well as patients with implants. Approximately half of all facilities responded that they cannot recognize implants, and many facilities did not know anything about oral care for implant patients. Residents with implants were reported at 19% of all facilities. Also, the facilities pointed out problems with implants relating to the difference in oral care between implants and natural teeth. There are people with implants in some 20% of caregiving facilities, and there is a low level of understanding regarding implants and their care among nurses and care providers who are providing daily oral care. © 2013 Wiley Periodicals, Inc.

  8. Long-term venous access using a subcutaneous implantable drug delivery system.

    PubMed Central

    Soo, K. C.; Davidson, T. I.; Selby, P.; Westbury, G.

    1985-01-01

    To facilitate long-term venous access in patients receiving chemotherapy, a subcutaneous totally implantable system (Port-a-Cath, Phamacia) has been used in 14 patients. The method of implantation and the advantages over conventional central venous catheters are discussed. The expense of the system necessitates careful patient selection. PMID:4037644

  9. [LONG TERM FOLLOW-UP OF TRANSCATHETER SELF EXPANDABLE AORTIC VALVE IMPLANTATION].

    PubMed

    Chen, Shmuel; Zenios, Vicky; Gilon, Dan; Planer, David; Beeri, Ronen; Lotan, Chaim; Danenberg, Haim D

    2018-03-01

    Aortic stenosis is the most common significant valvular disease in the western world. These patients are treated operatively unless they are at high operative risk or inoperable. During the last decade an alternative approach has evolved - transcatheter aortic valve implantation (TAVI). This method was shown to be at least as effective and safe as the operative one. However, very little data exists on long term follow-up (5 years and above), especially regarding valve durability and patient survival. To present a long term follow-up on patients who underwent transcutaneous self-expandable aortic valve implantation in our department between the years 2008-2011. In September 2008 the first CoreValve implantation was performed in Israel at Hadassah Medical Center. All records of patients who were transplanted between 9.2008 and 10.2011 were reviewed. The function of the valve early after the procedure was compared to its function at the end of the follow-up period. A total of 38 patients (out of 71) survived at least 54 months, of them, 19 have an echocardiography examination at the end of the follow-up period. In all patients the implanted valve was found to function well at the end of the follow-up period, without significant stenosis or paravalvular leak. In fact, in approximately half of these patients, the degree of paravalvular leak decreased during the follow-up period. On long term (5 years) follow-up of patients who were implanted with the self-expandable aortic valve (CoreValve), no deterioration of the valve was observed. In fact, in approximately half of the patients, a decrease in the severity of the paravalvular leak was demonstrated.

  10. Concept Formation Skills in Long-Term Cochlear Implant Users

    ERIC Educational Resources Information Center

    Castellanos, Irina; Kronenberger, William G.; Beer, Jessica; Colson, Bethany G.; Henning, Shirley C.; Ditmars, Allison; Pisoni, David B.

    2015-01-01

    This study investigated if a period of auditory sensory deprivation followed by degraded auditory input and related language delays affects visual concept formation skills in long-term prelingually deaf cochlear implant (CI) users. We also examined if concept formation skills are mediated or moderated by other neurocognitive domains (i.e.,…

  11. Understanding long-term silver release from surface modified porous titanium implants.

    PubMed

    Shivaram, Anish; Bose, Susmita; Bandyopadhyay, Amit

    2017-08-01

    Prevention of orthopedic device related infection (ODRI) using antibiotics has met with limited amount of success and is still a big concern during post-surgery. As an alternative, use of silver as an antibiotic treatment to prevent surgical infections is being used due to the well-established antimicrobial properties of silver. However, in most cases silver is used in particulate form with wound dressings or with short-term devices such as catheters but not with load-bearing implants. We hypothesize that strongly adherent silver to load-bearing implants can offer longer term solution to infection in vivo. Keeping that in mind, the focus of this study was to understand the long term release study of silver ions for a period of minimum 6months from silver coated surface modified porous titanium implants. Implants were fabricated using a LENS™ system, a powder based additive manufacturing technique, with at least 25% volume porosity, with and without TiO 2 nanotubes in phosphate buffer saline (pH 7.4) to see if the total release of silver ions is within the toxic limit for human cells. Considering the fact that infection sites may reduce the local pH, silver release was also studied in acetate buffer (pH 5.0) for a period of 4weeks. Along with that, the osseointegrative properties as well as cytotoxicity of porous titanium implants were assessed in vivo for a period of 12weeks using a rat distal femur model. In vivo results indicate that porous titanium implants with silver coating show comparable, if not better, biocompatibility and bonding at the bone-implant interface negating any concerns related to toxicity related to silver to normal cells. The current research is based on our recently patented technology, however focused on understanding longer-term silver release to mitigate infection related problems in load-bearing implants that can even arise several months after the surgery. Prevention of orthopedic device related infection using antibiotics has met

  12. Short-Term and Working Memory Impairments in Early-Implanted, Long-Term Cochlear Implant Users Are Independent of Audibility and Speech Production.

    PubMed

    AuBuchon, Angela M; Pisoni, David B; Kronenberger, William G

    2015-01-01

    To determine whether early-implanted, long-term cochlear implant (CI) users display delays in verbal short-term and working memory capacity when processes related to audibility and speech production are eliminated. Twenty-three long-term CI users and 23 normal-hearing controls each completed forward and backward digit span tasks under testing conditions that differed in presentation modality (auditory or visual) and response output (spoken recall or manual pointing). Normal-hearing controls reproduced more lists of digits than the CI users, even when the test items were presented visually and the responses were made manually via touchscreen response. Short-term and working memory delays observed in CI users are not due to greater demands from peripheral sensory processes such as audibility or from overt speech-motor planning and response output organization. Instead, CI users are less efficient at encoding and maintaining phonological representations in verbal short-term memory using phonological and linguistic strategies during memory tasks.

  13. Short-Term and Working Memory Impairments in Early-Implanted, Long-Term Cochlear Implant Users Are Independent of Audibility and Speech Production

    PubMed Central

    AuBuchon, Angela M.; Pisoni, David B.; Kronenberger, William G.

    2015-01-01

    OBJECTIVES Determine if early-implanted, long-term cochlear implant (CI) users display delays in verbal short-term and working memory capacity when processes related to audibility and speech production are eliminated. DESIGN Twenty-three long-term CI users and 23 normal-hearing controls each completed forward and backward digit span tasks under testing conditions which differed in presentation modality (auditory or visual) and response output (spoken recall or manual pointing). RESULTS Normal-hearing controls reproduced more lists of digits than the CI users, even when the test items were presented visually and the responses were made manually via touchscreen response. CONCLUSIONS Short-term and working memory delays observed in CI users are not due to greater demands from peripheral sensory processes such as audibility or from overt speech-motor planning and response output organization. Instead, CI users are less efficient at encoding and maintaining phonological representations in verbal short-term memory utilizing phonological and linguistic strategies during memory tasks. PMID:26496666

  14. 21 CFR 880.5970 - Percutaneous, implanted, long-term intravascular catheter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Percutaneous, implanted, long-term intravascular catheter. 880.5970 Section 880.5970 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital...

  15. 21 CFR 880.5970 - Percutaneous, implanted, long-term intravascular catheter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Percutaneous, implanted, long-term intravascular catheter. 880.5970 Section 880.5970 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital...

  16. 21 CFR 880.5970 - Percutaneous, implanted, long-term intravascular catheter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Percutaneous, implanted, long-term intravascular catheter. 880.5970 Section 880.5970 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital...

  17. 21 CFR 880.5970 - Percutaneous, implanted, long-term intravascular catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Percutaneous, implanted, long-term intravascular catheter. 880.5970 Section 880.5970 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital...

  18. 21 CFR 880.5970 - Percutaneous, implanted, long-term intravascular catheter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Percutaneous, implanted, long-term intravascular catheter. 880.5970 Section 880.5970 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital...

  19. Short dental implants in patients with oral lichen planus: a long-term follow-up.

    PubMed

    Anitua, E; Piñas, L; Escuer-Artero, V; Fernández, R S; Alkhraisat, M H

    2018-04-01

    Oral lichen planus is associated with the Koebner phenomenon, and trauma may exacerbate oral lesions. Short dental implants, as alternatives to bony augmentation, would reduce the number of interventions and their morbidity. However, we know of no studies that have analysed the long-term outcomes of short implants in patients with oral lichen planus. We have therefore designed a retrospective study of such patients treated with short implants (≤8.5mm long), with survival of implants as the main outcome. The secondary outcomes were marginal bone loss and the development of complications. We calculated the implants' survival and compared the outcomes statistically between erosive and reticular oral lichen planus. Sixty-six short implants were placed in 23 patients with a mean (SD) age of 58 (7) years. The mean (SD) peri-implant bone loss was 0.96 (0.89) mm mesially and 0.99 (1.1) mm distally. Sixty-five of the 66 implants survived with a mean (SD) follow-up of 68 (32) months, and there were no significant differences between erosive and reticular disease. Stable long-term outcomes can be expected for short implants placed in patients with oral lichen planus, and graftless rehabilitation of missing teeth could be possible in these patients if short implants were used. Copyright © 2018 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  20. Electrocardiographic Predictors of Long-Term Cardiac Pacing Dependency Following Transcatheter Aortic Valve Implantation.

    PubMed

    Naveh, Sivan; Perlman, Gidon Y; Elitsur, Yair; Planer, David; Gilon, Dan; Leibowitz, David; Lotan, Chaim; Danenberg, Haim; Alcalai, Ronny

    2017-02-01

    Conduction disorders requiring permanent pacemaker (PPM) implantation are a known complication of transcatheter aortic valve implantation (TAVI). Indications for permanent pacing in this setting are still controversial. The study aim was to characterize the natural history of conduction disorders related to TAVI, and to identify predictors for long-term pacing dependency. Consecutive patients who underwent TAVI were included in this prospective observational study. The conduction system was investigated by reviewing 12-lead ECGs during hospitalization and up to 1-year follow-up and by analyzing pacemaker interrogation data. Multivariate analysis was performed in order to identify independent predictors for pacemaker dependency. Of 110 patients included in the analysis, 38 (34.5%) underwent PPM implantation. Of those, 26 (68.4%) had a long-term pacing dependency (required PPM), while 12 (31.6%) did not (not-required PPM). Logistic regression revealed that baseline RBBB (P = 0.01, OR = 18.0), baseline PR interval (P = 0.019, OR = 1.14), post-TAVI PR interval and the change in PR interval from baseline (P < 0.001 for both, OR = 1.17 for each 10 milliseconds increment) were independent predictors for long-term pacing dependency. A PR interval increment of greater than 28 milliseconds had the best accuracy in predicting pacemaker dependency. Increased pre- and postprocedural PR intervals and pre-existing RBBB are reliable predictors for long-term PPM dependency, while left bundle branch block or QRS width are misleading factors. Our study suggests that the decision for implanting PPM after TAVI should be based mostly on the prolongation of the PR interval. © 2016 Wiley Periodicals, Inc.

  1. Long-term follow-up of patients with retinitis pigmentosa (RP) receiving intraocular ciliary neurotrophic factor implants

    PubMed Central

    Birch, David G.; Bennett, Lea D.; Duncan, Jacque L.; Weleber, Richard G.; Pennesi, Mark E.

    2016-01-01

    Purpose To evaluate the long-term efficacy of ciliary neurotrophic factor delivered via an intraocular encapsulated cell implant for the treatment of retinitis pigmentosa (RP). Design Long-term follow up of a multicenter, sham-controlled study. Methods Thirty-six patients at three CNTF4 sites were randomly assigned to receive a high- or low- dose implant in one eye and sham surgery in the fellow eye. The primary endpoint (change in visual field sensitivity at 12 months) has been reported previously.1 Here we report long-term visual acuity, visual field and optical coherence tomography (OCT) outcomes in 24 patients either retaining or explanting the device at 24 months relative to sham-treated eyes. Results Eyes retaining the implant showed significantly greater visual field loss from baseline than either explanted eyes or sham eyes through 42 months. By 60 months and continuing through 96 months, visual field loss was comparable among sham-treated eyes, eyes retaining the implant and explanted eyes, as was visual acuity and OCT macular volume. Conclusions Over the short term, ciliary neurotrophic factor released continuously from an intra-vitreal implant lead to loss of total visual field sensitivity that was greater than the natural progression in the sham-treated eye. This additional loss of sensitivity related to the active implant was reversible when the implant was removed. Over the long term (60 – 96 months), there was no evidence of efficacy for visual acuity, visual field sensitivity or OCT measures of retinal structure. PMID:27457255

  2. Long-Term Mortality Effect of Early Pacemaker Implantation After Surgical Aortic Valve Replacement.

    PubMed

    Greason, Kevin L; Lahr, Brian D; Stulak, John M; Cha, Yong-Mei; Rea, Robert F; Schaff, Hartzell V; Dearani, Joseph A

    2017-10-01

    The need for pacemaker implantation is a well-described complication of aortic valve replacement. Not so well described is the effect such an event has on long-term outcome. This study reviewed a 21-year experience at the Mayo Clinic (Rochester, Minnesota) with aortic valve replacement to understand the influence of early postoperative pacemaker implantation on long-term mortality rates more clearly. This study retrospectively reviewed the records of 5,842 patients without previous pacemaker implantation who underwent surgical aortic valve replacement from January 1993 through June 2014. The median age of these patients was 73 years (range, 65 to 79 years), the median ejection fraction was 62% (range, 53% to 68%), 3,853 patients were male (66%), and coronary artery bypass graft operation was performed in 2,553 (44%) of the patients studied. Early pacemaker implantation occurred in 146 patients (2.5%) within 30 days of surgical aortic valve replacement. The median follow-up of patients was 11.1 years (range, 5.8 to 16.5 years), and all-cause mortality rates were 2.4% at 30 days, 6.4% at 1 year, 23.1% at 5 years, 48.3% at 10 years, and 67.9% at 15 years postoperatively. Early pacemaker implantation was associated with an increased risk of death after multivariable adjustment for baseline patients' characteristics (hazard ratio, 1.49; 95% confidence interval, 1.20, 1.84; p < 0.001). Early pacemaker implantation as a complication of surgical aortic valve replacement is associated with an increased risk of long-term death. Valve replacement-related pacemaker implantation rates should be important considerations with respect to new valve replacement paradigms, especially in younger and lower-risk patients. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Advanced immediate functional loading: requirements for long-term success in modern implant dentistry.

    PubMed

    Romanos, Georgios E

    2014-01-01

    There are benefits to be derived from the use of advanced surgical protocols in conjunction with immediate functional loading using various dental implant designs and implant-abutment connections. Clinical protocols with simultaneous bone grafting, immediate implant placement, and/or sinus augmentations when a shortened treatment period is needed are included in this report, with the aim of providing understanding of the main protocol characteristics and prerequisites for long-term success in implant dentistry. This article presents three clinical cases that illustrate possibilities for advanced immediate loading using different implant designs. It demonstrates treatment of severe bone defects and the facilitation of placing implants in regenerated bone that can be immediately loaded.

  4. Long-Term Health Outcomes in Women With Silicone Gel Breast Implants: A Systematic Review.

    PubMed

    Balk, Ethan M; Earley, Amy; Avendano, Esther A; Raman, Gowri

    2016-02-02

    Silicone gel breast implants were removed from the U.S. market for cosmetic use in 1992 owing to safety concerns. They were reintroduced in 2006, with a call for improved surveillance of clinical outcomes. To systematically review the literature regarding specific long-term health outcomes in women with silicone gel breast implants, including cancer; connective tissue, rheumatologic, and autoimmune diseases; neurologic diseases; reproductive issues, including lactation; offspring issues; and mental health issues (depression and suicide). MEDLINE, EMBASE, and Ovid Healthstar (inception through 30 June 2015), and the Cochrane Central Register of Controlled Trials and Cochrane Database of Systematic Reviews (through the first quarter of 2015). 4 researchers double-screened articles for longitudinal studies that compared women with and without breast implants and reported long-term health outcomes of interest. 4 researchers extracted data on participant and implant characteristics, analytic methods, and results. 32 studies (in 58 publications) met eligibility criteria. Random-effects model meta-analyses of effect sizes were conducted when feasible. For most outcomes, there was at most only a single adequately adjusted study, which usually found no significant associations. There were possible associations with decreased risk for primary breast and endometrial cancers and increased risks for lung cancer, rheumatoid arthritis, Sjögren syndrome, and Raynaud syndrome. Evidence on breast implants and other outcomes either was limited or did not exist. The evidence was most frequently not specific to silicone gel implants, and studies were rarely adequately adjusted for potential confounders. The evidence remains inconclusive about any association between silicone gel implants and long-term health outcomes. Better evidence is needed from existing large studies, which can be reanalyzed to clarify the strength of associations between silicone gel implants and health outcomes

  5. [Long-term effects of permanent pacemaker implantation on tricuspid valve regurgitation].

    PubMed

    Ren, Chong-lei; Wang, Yao; Wang, Rong; Li, Bo-jun; Geng, Ren-yi; Gao, Chang-qing

    2012-08-14

    To explore the long-term effects of permanent pacemaker implantation (PPI) on tricuspid valve regurgitation (TR) in Chinese patients so as to determine the incidence and related factors, evaluate its effects on heart structure and function and ascertain the exact mechanism of TR after PPI. A total of 430 patients undergoing permanent pacemaker replacement at our hospital between January 2000 and June 2011 were recruited. The patients with isolated atrial lead implantation procedures, significant heart valve disease or chronic obstructive pulmonary disease were excluded. The data of 108 patients who had Doppler echocardiograms performed before the first pacemaker implantation procedure and this pacemaker replacement procedure were obtained and retrospectively analyzed. According to the post-implant grade of TR, the patients were divided into two groups: normal tricuspid (n = 79) and abnormal tricuspid (n = 29). Their clinical characteristics and echocardiographic data between two groups were analyzed and compared. The mean follow-up time (from the first pacemaker implantation) was (13 ± 6) years (range: 4 - 34). Among 108 patients with initially normal tricuspid post-implant, 29 patients (26.9%) developed significant TR during the follow-up. In comparison to those in normal tricuspid group, the patients in abnormal tricuspid group had a longer time from the first pacemaker implantation ((16 ± 7) vs (12 ± 5) years, P = 0.003), more transtricuspid leads (1.31 ± 0.66 vs 1.10 ± 0.30, P = 0.026), larger right atrial size ((38 ± 7) vs (35 ± 4) mm, P = 0.028) and higher prevalence of mild TR and mitral valve regurgitation (MR) pre-implantation (TR: 21% vs 4%, P = 0.015, MR: 28% vs 5%, P = 0.003). The size of right atrium, right ventricle and left atrium in abnormal tricuspid group were more than those in normal tricuspid group. The prevalence of significant MR post-implantation in abnormal tricuspid group was higher than that in normal tricuspid group. The ejection

  6. Dental Implants in the Elderly Population: A Long-Term Follow-up.

    PubMed

    Compton, Sharon M; Clark, Danielle; Chan, Stephanie; Kuc, Iris; Wubie, Berhanu A; Levin, Liran

    The objectives of this study were to evaluate implant survival and success in the elderly population and to assess indicators and risk factors for success or failure of dental implants in older adults (aged 60 years and older). This historical prospective study was developed from a cohort of patients born prior to 1950 who received dental implants in a single private dental office. Implant survival and marginal bone levels were recorded and analyzed with regard to different patient- and implant-related factors. The study examined 245 patient charts and 1,256 implants from one dental clinic. The mean age at the time of implant placement was 62.18 ± 8.6 years. Smoking was reported by 9.4% of the cohort studied. The overall survival rate of the implants was 92.9%; 7.1% of the implants had failed. Marginal bone loss depicted by exposed threads was evident in 23.3% of the implants. Presenting with generalized periodontal disease and/or severe periodontal disease negatively influenced the survival probability of the implant. Implants placed in areas where bone augmentation was performed prior to or during implant surgery did not have the same longevity compared with those that did not have augmentation prior to implantation. The overall findings concluded that implants can be successfully placed in older adults. A variety of factors are involved in the long-term success of the implant, and special consideration should be taken prior to placing implants in older adults to limit the influence of those risk factors.

  7. Long-term Survival of Straumann Dental Implants with TPS Surfaces: A Retrospective Study with a Follow-up of 12 to 23 Years.

    PubMed

    Becker, Stephan T; Beck-Broichsitter, Benedicta E; Rossmann, Christian M; Behrens, Eleonore; Jochens, Arne; Wiltfang, Jörg

    2016-06-01

    The aim of this study was to evaluate the long-term dental implant survival rates of Straumann dental implants in a university hospital environment over 12 to 23 years. A total of 388 Straumann dental implants with titanium-sprayed surfaces (TPS) were inserted in 92 patients between 1988 and 1999 in the Department of Oral and Maxillofacial Surgery of the University Hospital Schleswig-Holstein in Kiel, and they were reevaluated with standardized clinical and radiological exams. Kaplan-Meier analyses were performed for individual factors. Cox proportional hazard regression analysis was used to detect the factors influencing long-term implant failure. The long-term implant survival rate was 88.03% after an observation time of 12.2 to 23.5 years. Cox regression revealed statistically significant influences of the International Team for Implantology (ITI) implantation type (p = .00354) and tobacco smoking (p = .01264) on implant failure. A proportion 82.8% of the patients with implant losses had a medical history of periodontitis. Peri-implantitis was diagnosed in 9.7% of the remaining implants in the long-term survey. This study emphasized the long-term rehabilitation capabilities of Straumann dental implants in complex cases. The survival rates after several years constitute important information for patients, as well as for clinicians, in deciding about different concepts of tooth replacement. Patient-related and technical factors - determined before implant placement - could help to predict the risk of implant loss. © 2015 Wiley Periodicals, Inc.

  8. Long-term contraception in a small implant: A review of Suprelorin (deslorelin) studies in cats.

    PubMed

    Fontaine, Christelle

    2015-09-01

    Deslorelin (Suprelorin®; Virbac) is a gonadotropin-releasing hormone (GnRH) agonist licensed in select countries for the long-term suppression of fertility in adult male dogs and male ferrets. This article summarizes studies investigating the use of deslorelin implants for the long-term suppression of fertility in male and female domestic cats. Slow-release deslorelin implants have been shown to generate effective, safe and reversible long-term contraception in male and female cats. In pubertal cats, a 4.7 mg deslorelin implant suppressed steroid sex hormones for an average of approximately 20 months (range 15-25 months) in males and an average of approximately 24 months (range 16-37 months) in females. Reversibility has been demonstrated by fertile matings approximately 2 years post-treatment in both male and female adult cats. In prepubertal female cats of approximately 4 months of age, puberty was postponed to an average of approximately 10 months of age (range 6-15 months) by a 4.7 mg deslorelin implant. The large variability in the duration of suppression of gonadal activity makes the definition of the optimal time for reimplantation quite challenging. In addition, the temporary stimulation phase occurring in the weeks following deslorelin implantation can induce in adult female cats a fertile estrus that needs to be managed to avoid unwanted pregnancy. Longer duration and larger scale controlled field studies implementing blinding, a negative control group and a carefully controlled randomization to each group are needed. Furthermore, the effects of repeated treatment need to be investigated. Finally, the effect of treatment on growth and bone quality of prepubertal cats needs to be assessed. However, the ease of use, long-lasting effects and reversibility of deslorelin implants are strong positive points supporting their use for controlling feline reproduction. © The Author(s) 2015.

  9. Long-Term Asymmetric Hearing Affects Cochlear Implantation Outcomes Differently in Adults with Pre- and Postlingual Hearing Loss

    PubMed Central

    Boisvert, Isabelle; McMahon, Catherine M.; Dowell, Richard C.; Lyxell, Björn

    2015-01-01

    In many countries, a single cochlear implant is offered as a treatment for a bilateral hearing loss. In cases where there is asymmetry in the amount of sound deprivation between the ears, there is a dilemma in choosing which ear should be implanted. In many clinics, the choice of ear has been guided by an assumption that the reorganisation of the auditory pathways caused by longer duration of deafness in one ear is associated with poorer implantation outcomes for that ear. This assumption, however, is mainly derived from studies of early childhood deafness. This study compared outcomes following implantation of the better or poorer ear in cases of long-term hearing asymmetries. Audiological records of 146 adults with bilateral hearing loss using a single hearing aid were reviewed. The unaided ear had 15 to 72 years of unaided severe to profound hearing loss before unilateral cochlear implantation. 98 received the implant in their long-term sound-deprived ear. A multiple regression analysis was conducted to assess the relative contribution of potential predictors to speech recognition performance after implantation. Duration of bilateral significant hearing loss and the presence of a prelingual hearing loss explained the majority of variance in speech recognition performance following cochlear implantation. For participants with postlingual hearing loss, similar outcomes were obtained by implanting either ear. With prelingual hearing loss, poorer outcomes were obtained when implanting the long-term sound-deprived ear, but the duration of the sound deprivation in the implanted ear did not reliably predict outcomes. Contrary to an apparent clinical consensus, duration of sound deprivation in one ear has limited value in predicting speech recognition outcomes of cochlear implantation in that ear. Outcomes of cochlear implantation are more closely related to the period of time for which the brain is deprived of auditory stimulation from both ears. PMID:26043227

  10. Acute and Long-term Results After Contemporary Subcutaneous Implantable Cardioverter-defibrillator Implantation: A Single-center Experience.

    PubMed

    Arias, Miguel A; Pachón, Marta; Akerström, Finn; Puchol, Alberto; Martín-Sierra, Cristina; Rodríguez-Padial, Luis

    2017-12-05

    The subcutaneous implantable cardioverter-defibrillator (S-ICD) has emerged as an alternative to the transvenous defibrillator. The incidence of complications is similar, with inappropriate shocks (IS) being more frequent than those occurring with contemporary programming of transvenous defibrillators. Several improvements have been implemented after the S-ICD was approved for use in Europe in 2009. This study reports the results of S-ICD use in a single center, whose experience began late, at the end of 2013. Prospective observational study including consecutive patients with defibrillator indication and no indication for either permanent pacing or cardiac resynchronization who underwent S-ICD implantation. Implant data and long-term follow-up were analyzed. An S-ICD was implanted in 50 patients who were deemed suitable after electrocardiographic screening. The mean age was 46.9±15 (range, 15-78) years and 72% were male. Thirty eight percent had left ventricular ejection fraction ≤ 35%. The most frequent heart disease was ischemic heart disease (34%), followed by hypertrophic cardiomyopathy (18%). The intermuscular technique was used, with 3 incisions in 10% and 2 incisions in the remaining 90%. Ventricular fibrillation was induced in 49 patients, with 100% effectiveness in their conversion. After a mean follow-up of 18.1 (range, 2.3-44.8) months, there were no late complications requiring surgical revision, the rate of IS was 0%, and 1 patient (2%) experienced appropriate shocks. Improvements in technology, implant technique and device programming, along with appropriate patient selection, have led to outstanding acute and long-term results, especially regarding the absence of both IS and complications requiring surgical revision. Copyright © 2017 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  11. Psychosocial Outcomes in Long-Term Cochlear Implant Users.

    PubMed

    Castellanos, Irina; Kronenberger, William G; Pisoni, David B

    The objectives of this study were to investigate psychosocial outcomes in a sample of prelingually deaf, early-implanted children, adolescents, and young adults who are long-term cochlear implant (CI) users and to examine the extent to which language and executive functioning predict psychosocial outcomes. Psychosocial outcomes were measured using two well-validated, parent-completed checklists: the Behavior Assessment System for Children and the Conduct Hyperactive Attention Problem Oppositional Symptom. Neurocognitive skills were measured using gold standard, performance-based assessments of language and executive functioning. CI users were at greater risk for clinically significant deficits in areas related to attention, oppositional behavior, hyperactivity-impulsivity, and social-adaptive skills compared with their normal-hearing peers, although the majority of CI users scored within average ranges relative to Behavior Assessment System for Children norms. Regression analyses revealed that language, visual-spatial working memory, and inhibition-concentration skills predicted psychosocial outcomes. Findings suggest that underlying delays and deficits in language and executive functioning may place some CI users at a risk for difficulties in psychosocial adjustment.

  12. Early Postimplant Speech Perception and Language Skills Predict Long-Term Language and Neurocognitive Outcomes Following Pediatric Cochlear Implantation

    PubMed Central

    Kronenberger, William G.; Castellanos, Irina; Pisoni, David B.

    2017-01-01

    Purpose We sought to determine whether speech perception and language skills measured early after cochlear implantation in children who are deaf, and early postimplant growth in speech perception and language skills, predict long-term speech perception, language, and neurocognitive outcomes. Method Thirty-six long-term users of cochlear implants, implanted at an average age of 3.4 years, completed measures of speech perception, language, and executive functioning an average of 14.4 years postimplantation. Speech perception and language skills measured in the 1st and 2nd years postimplantation and open-set word recognition measured in the 3rd and 4th years postimplantation were obtained from a research database in order to assess predictive relations with long-term outcomes. Results Speech perception and language skills at 6 and 18 months postimplantation were correlated with long-term outcomes for language, verbal working memory, and parent-reported executive functioning. Open-set word recognition was correlated with early speech perception and language skills and long-term speech perception and language outcomes. Hierarchical regressions showed that early speech perception and language skills at 6 months postimplantation and growth in these skills from 6 to 18 months both accounted for substantial variance in long-term outcomes for language and verbal working memory that was not explained by conventional demographic and hearing factors. Conclusion Speech perception and language skills measured very early postimplantation, and early postimplant growth in speech perception and language, may be clinically relevant markers of long-term language and neurocognitive outcomes in users of cochlear implants. Supplemental materials https://doi.org/10.23641/asha.5216200 PMID:28724130

  13. Osseointegration of Plateau Root Form Implants: Unique Healing Pathway Leading to Haversian-Like Long-Term Morphology.

    PubMed

    Coelho, Paulo G; Suzuki, Marcelo; Marin, Charles; Granato, Rodrigo; Gil, Luis F; Tovar, Nick; Jimbo, Ryo; Neiva, Rodrigo; Bonfante, Estevam A

    2015-01-01

    Endosteal dental implants have been utilized as anchors for dental and orthopedic rehabilitations for decades with one of the highest treatment success rates in medicine. Such success is due to the phenomenon of osseointegration where after the implant surgical placement, bone healing results into an intimate contact between bone and implant surface. While osseointegration is an established phenomenon, the route which osseointegration occurs around endosteal implants is related to various implant design factors including surgical instrumentation and implant macro, micro, and nanometer scale geometry. In an implant system where void spaces (healing chambers) are present between the implant and bone immediately after placement, its inherent bone healing pathway results in unique opportunities to accelerate the osseointegration phenomenon at the short-term and its maintenance on the long-term through a haversian-like bone morphology and mechanical properties.

  14. Long-term results after artificial iris implantation in patients with aniridia.

    PubMed

    Rickmann, Annekatrin; Szurman, Peter; Januschowski, Kai; Waizel, Maria; Spitzer, Martin S; Boden, Karl T; Szurman, Gesine B

    2016-07-01

    The custom-made, flexible artificial iris developed by HumanOptics and Koch can reconstruct the anterior segment of patients with aniridia. The aim of this study was to evaluate the long-term clinical outcome and complication spectrum after artificial iris implantation and the role of the embedded fiber mesh in view of specific complications. In this retrospective interventional case series, patients received an artificial iris between 2004 and 2013. Only eyes with a minimum follow-up period of 2 years were included. Indications were congenital, traumatic, or iatrogenic aniridia. The artificial iris was used either with or without embedded fiber mesh for partial or full prostheses. We included 34 patients (mean age 48.8 years; SD ±17.2) with a mean follow-up of 50.0 months (SD ±18.9 months). No repositioning of prostheses was necessary. In cases of keratopathy (17.6 %) visual function increased from baseline mean 1.6 logMAR (SD ±0.7) to 1.2 logMAR (SD ±0.7) after artificial iris implantation. The remaining iris tissue darkened during the follow-up in 23.5 % (83.3 % with and 10.7 % without mesh), 8.8 % developed glaucoma (50 % with and 0 % without mesh) and 14.7 % needed consecutive surgery after prostheses implantation (50 % with and 7.1 % without mesh). In three out of seven trauma cases (42.9 %) silicone oil was spilled into the anterior chamber after 2.5 years on average. The artificial iris prosthesis revealed a good clinical outcome in terms of long-term stability, cosmetic appearance, visual function, and represents a good functional iris diaphragm for compartmentalisation. Complications such as glaucoma, darkening of iris tissue, and need for consecutive anterior segment surgery are clearly associated with implants with integrated fiber mesh, but not to those without. Hence, the use of full iris prostheses without embedded fiber mesh, even in cases with remnant iris, and the use of slightly smaller implants than officially recommended may

  15. Long-Term Implanted cOFM Probe Causes Minimal Tissue Reaction in the Brain

    PubMed Central

    Hochmeister, Sonja; Asslaber, Martin; Kroath, Thomas; Pieber, Thomas R.; Sinner, Frank

    2014-01-01

    This study investigated the histological tissue reaction to long-term implanted cerebral open flow microperfusion (cOFM) probes in the frontal lobe of the rat brain. Most probe-based cerebral fluid sampling techniques are limited in application time due to the formation of a glial scar that hinders substance exchange between brain tissue and the probe. A glial scar not only functions as a diffusion barrier but also alters metabolism and signaling in extracellular brain fluid. cOFM is a recently developed probe-based technique to continuously sample extracellular brain fluid with an intact blood-brain barrier. After probe implantation, a 2 week healing period is needed for blood-brain barrier reestablishment. Therefore, cOFM probes need to stay in place and functional for at least 15 days after implantation to ensure functionality. Probe design and probe materials are optimized to evoke minimal tissue reaction even after a long implantation period. Qualitative and quantitative histological tissue analysis revealed no continuous glial scar formation around the cOFM probe 30 days after implantation and only a minor tissue reaction regardless of perfusion of the probe. PMID:24621608

  16. Meta-analysis of long-term outcomes of drug-eluting stent implantations for chronic total coronary occlusions.

    PubMed

    Ma, Jian; Yang, Weiwei; Singh, Manpreet; Peng, Tianqing; Fang, Ningyuan; Wei, Meng

    2011-01-01

    In the treatment of chronic total occlusions (CTOs), some uncertainty exists regarding the effect of drug-eluting stents (DESs) compared with the effects of bare mental stents (BMSs). We reviewed outcomes of DES vs. BMS implantation for CTO lesions, to evaluate the risk-benefit ratio of DES implantation. Relevant studies of long-term clinical outcomes or angiographic outcomes of both BMS and DES implantation were examined. The primary endpoint comprised major adverse cardiovascular events (MACEs), including all-cause deaths, myocardial infarctions (MIs), and target lesion revascularizations (TLRs). A fixed-effect model and random-effect model were used to analyze the pooling results. Ten studies were included according to the selection criteria. Eight were nonrandomized controlled trials, and two consisted of a randomized controlled comparison between DES and BMS implantation. No significant difference was evident for in-hospital MACE rates between the two groups (odds ratio [OR], 1.07; 95% confidence interval [CI], .53 to 2.13), but the long-term MACE rates in the DES group were significantly lower than in the BMS group (OR, .22; 95% CI, .13 to .38; P < .00001). The rates of stent restenosis and reocclusions were also significantly lower in the DES group (OR, .14; 95% CI, .09 to .20; and OR, .23; 95% CI, .12 to .41, respectively). Implantation of the DES improves long-term angiographic and clinical outcomes compared with BMS in the treatment of CTO lesions. Copyright © 2011 Elsevier Inc. All rights reserved.

  17. Long-term outcome of cemented versus screw-retained implant-supported partial restorations.

    PubMed

    Nissan, Joseph; Narobai, Demitri; Gross, Ora; Ghelfan, Oded; Chaushu, Gavriel

    2011-01-01

    The present study was designed to compare the long-term outcome and complications of cemented versus screw-retained implant restorations in partially edentulous patients. Consecutive patients with bilateral partial posterior edentulism comprised the study group. Implants were placed, and cemented or screw-retained restorations were randomly assigned to the patients in a split-mouth design. Follow-up (up to 15 years) examinations were performed every 6 months in the first year and every 12 months in subsequent years. The following parameters were evaluated and recorded at each recall appointment: ceramic fracture, abutment screw loosening, metal frame fracture, Gingival Index, and marginal bone loss. Thirty-eight patients were treated with 221 implants to support partial prostheses. No implants during the follow-up period (mean follow-up, 66 ± 47 months for screw-retained restorations [range, 18 to 180 months] and 61 ± 40 months for cemented restorations [range, 18 to 159 months]). Ceramic fracture occurred significantly more frequently (P < .001) in screw-retained (38% ± 0.3%) than in cemented (4% ± 0.1%) restorations. Abutment screw loosening occurred statistically significantly more often (P = .001) in screw-retained (32% ± 0.3%) than in cement-retained (9% ± 0.2%) restorations. There were no metal frame fractures in either type of restoration. The mean Gingival Index scores were statistically significantly higher (P < .001) for screw-retained (0.48 ± 0.5) than for cemented (0.09 ± 0.3) restorations. The mean marginal bone loss was statistically significantly higher (P < .001) for screw-retained (1.4 ± 0.6 mm) than for cemented (0.69 ± 0.5 mm) restorations. The long-term outcome of cemented implant-supported restorations was superior to that of screw-retained restorations, both clinically and biologically.

  18. Long-term outcome in patients receiving permanent pacemaker implantation for atrioventricular block

    PubMed Central

    Liao, Jo-Nan; Chao, Tze-Fan; Tuan, Ta-Chuan; Kong, Chi-Woon; Chen, Shih-Ann

    2016-01-01

    Abstract A permanent pacemaker (PPM) with dual chamber pacing (DDD) offers atrioventricular synchronization for patients with atrioventricular block (AVB). Single lead atrial synchronous ventricular pacing mode (VDD) is an alternative, but there are concerns about its efficacy and risk of atrial undersensing. Whether VDD can be a good alternative in patients with AVB remains unknown. The aim of the present study was to compare the long-term risk of mortality of VDD with DDD pacing. A total of 207 patients undergoing PPM implantations for AVB with VDD mode were enrolled from 2000 to 2013. Another 828 age- and sex-matched patients undergoing DDD implantations during the same period of time were selected as the control group in a 1 to 4 ratio. The study endpoint was mortality. A total of 1035 patients (64.3% male) were followed up for 46.5 ± 43.2 months. The mean ages were 75.0 years for VDD, and 74.9 years for DDD. The Kaplan–Meier survival analysis showed no significant difference in long-term survival between the VDD and DDD groups (log-rank P = 0.313). After adjustment for baseline characteristics, the VDD and DDD groups had a similar long-term prognosis with an adjusted hazard ratio of 0.875 (P = 0.445). Further analyses for the risk of cardiovascular and noncardiovascular deaths also showed no significant differences between the 2 groups. The long-term prognosis of VDD mode is comparable to that of DDD mode. Single lead VDD can be considered as an alternative choice in patients with AVB without sinus nodal dysfunction. PMID:27583889

  19. Glucose Monitoring in Individuals With Diabetes Using a Long-Term Implanted Sensor/Telemetry System and Model.

    PubMed

    Lucisano, Joseph Y; Routh, Timothy L; Lin, Joe T; Gough, David A

    2017-09-01

    The use of a fully implanted first-generation prototype sensor/telemetry system is described for long-term monitoring of subcutaneous tissue glucose in a small cohort of people with diabetes. Sensors are based on a membrane containing immobilized glucose oxidase and catalase coupled to oxygen electrodes and a telemetry system, integrated as an implant. The devices remained implanted for up to 180 days, with signals transmitted every 2 min to external receivers. The data include signal recordings from glucose clamps and spontaneous glucose excursions, matched, respectively, to reference blood glucose and finger-stick values. The sensor signals indicate dynamic tissue glucose, for which there is no independent standard, and a model describing the relationship between blood glucose and the signal is, therefore, included. The values of all model parameters have been estimated, including the permeability of adjacent tissues to glucose, and equated to conventional mass transfer parameters. As a group, the sensor calibration varied randomly at an average rate of -2.6%/week. Statistical correlation indicated strong association between the sensor signals and reference glucose values. Continuous long-term glucose monitoring in individuals with diabetes is feasible with this system. All therapies for diabetes are based on glucose control, and therefore, require glucose monitoring. This fully implanted long-term sensor/telemetry system may facilitate a new era of management of the disease.

  20. Glucose Monitoring in Individuals with Diabetes using a Long-Term Implanted Sensor/Telemetry System and Model

    PubMed Central

    Lucisano, Joseph Y.; Routh, Timothy L.; Lin, Joe T.; Gough, David A.

    2017-01-01

    Objective The use of a fully implanted, first-generation prototype sensor/telemetry system is described for long-term monitoring of subcutaneous tissue glucose in a small cohort of people with diabetes. Methods Sensors are based on a membrane containing immobilized glucose oxidase and catalase coupled to oxygen electrodes and a telemetry system, integrated as an implant. The devices remained implanted for up to 180 days, with signals transmitted every 2 minutes to external receivers. Results The data include signal recordings from glucose clamps and spontaneous glucose excursions, matched respectively to reference blood glucose and finger-stick values. The sensor signals indicate dynamic tissue glucose, for which there is no independent standard, and a model describing the relationship between blood glucose and the signal is therefore included. The values of all model parameters have been estimated, including the permeability of adjacent tissues to glucose, and equated to conventional mass transfer parameters. As a group, the sensor calibration varied randomly at an average rate of −2.6%/week. Statistical correlation indicated strong association between the sensor signals and reference glucose values. Conclusions Continuous, long-term glucose monitoring in individuals with diabetes is feasible with this system. Significance All therapies for diabetes are based on glucose control and therefore require glucose monitoring. This fully implanted, long-term sensor/telemetry system may facilitate a new era of management of the disease. PMID:27775510

  1. Long-term decoding of movement force and direction with a wireless myoelectric implant.

    PubMed

    Morel, Pierre; Ferrea, Enrico; Taghizadeh-Sarshouri, Bahareh; Audí, Josep Marcel Cardona; Ruff, Roman; Hoffmann, Klaus-Peter; Lewis, Sören; Russold, Michael; Dietl, Hans; Abu-Saleh, Lait; Schroeder, Dietmar; Krautschneider, Wolfgang; Meiners, Thomas; Gail, Alexander

    2016-02-01

    The ease of use and number of degrees of freedom of current myoelectric hand prostheses is limited by the information content and reliability of the surface electromyography (sEMG) signals used to control them. For example, cross-talk limits the capacity to pick up signals from small or deep muscles, such as the forearm muscles for distal arm amputations, or sites of targeted muscle reinnervation (TMR) for proximal amputations. Here we test if signals recorded from the fully implanted, induction-powered wireless Myoplant system allow long-term decoding of continuous as well as discrete movement parameters with better reliability than equivalent sEMG recordings. The Myoplant system uses a centralized implant to transmit broadband EMG activity from four distributed bipolar epimysial electrodes. Two Rhesus macaques received implants in their backs, while electrodes were placed in their upper arm. One of the monkeys was trained to do a cursor task via a haptic robot, allowing us to control the forces exerted by the animal during arm movements. The second animal was trained to perform a center-out reaching task on a touchscreen. We compared the implanted system with concurrent sEMG recordings by evaluating our ability to decode time-varying force in one animal and discrete reach directions in the other from multiple features extracted from the raw EMG signals. In both cases, data from the implant allowed a decoder trained with data from a single day to maintain an accurate decoding performance during the following months, which was not the case for concurrent surface EMG recordings conducted simultaneously over the same muscles. These results show that a fully implantable, centralized wireless EMG system is particularly suited for long-term stable decoding of dynamic movements in demanding applications such as advanced forelimb prosthetics in a wide range of configurations (distal amputations, TMR).

  2. Long-term decoding of movement force and direction with a wireless myoelectric implant

    NASA Astrophysics Data System (ADS)

    Morel, Pierre; Ferrea, Enrico; Taghizadeh-Sarshouri, Bahareh; Marcel Cardona Audí, Josep; Ruff, Roman; Hoffmann, Klaus-Peter; Lewis, Sören; Russold, Michael; Dietl, Hans; Abu-Saleh, Lait; Schroeder, Dietmar; Krautschneider, Wolfgang; Meiners, Thomas; Gail, Alexander

    2016-02-01

    Objective. The ease of use and number of degrees of freedom of current myoelectric hand prostheses is limited by the information content and reliability of the surface electromyography (sEMG) signals used to control them. For example, cross-talk limits the capacity to pick up signals from small or deep muscles, such as the forearm muscles for distal arm amputations, or sites of targeted muscle reinnervation (TMR) for proximal amputations. Here we test if signals recorded from the fully implanted, induction-powered wireless Myoplant system allow long-term decoding of continuous as well as discrete movement parameters with better reliability than equivalent sEMG recordings. The Myoplant system uses a centralized implant to transmit broadband EMG activity from four distributed bipolar epimysial electrodes. Approach. Two Rhesus macaques received implants in their backs, while electrodes were placed in their upper arm. One of the monkeys was trained to do a cursor task via a haptic robot, allowing us to control the forces exerted by the animal during arm movements. The second animal was trained to perform a center-out reaching task on a touchscreen. We compared the implanted system with concurrent sEMG recordings by evaluating our ability to decode time-varying force in one animal and discrete reach directions in the other from multiple features extracted from the raw EMG signals. Main results. In both cases, data from the implant allowed a decoder trained with data from a single day to maintain an accurate decoding performance during the following months, which was not the case for concurrent surface EMG recordings conducted simultaneously over the same muscles. Significance. These results show that a fully implantable, centralized wireless EMG system is particularly suited for long-term stable decoding of dynamic movements in demanding applications such as advanced forelimb prosthetics in a wide range of configurations (distal amputations, TMR).

  3. Long-term follow-up study of uncertainty and psychosocial adjustment among implantable cardioverter defibrillator recipients.

    PubMed

    Mauro, Ann Marie P

    2010-09-01

    Sudden cardiac death is an international health issue. Implantable defibrillators have been effective in the secondary prevention of sudden cardiac death and are increasingly being utilized for primary prevention in individuals without a prior history of cardiac arrest or sustained ventricular tachycardia. Although it has been well documented that some recipients experience psychological distress and have difficulty in adjusting to the device, long-term data on psychological outcomes are limited. The aims of this study were to determine: (a) if there is a long-term relationship between uncertainty and psychosocial adjustment among implantable cardioverter defibrillator (ICD) recipients; and (b) if changes in uncertainty and/or adjustment occur over time. A longitudinal, descriptive, correlational design was used for this long-term follow-up study (M=9.4 years, SD=.23). Ninety-four patients from 4 major teaching hospitals in New England who had participated in an investigation of uncertainty and adjustment at 1 and 8 weeks following an initial ICD implant between 1996 and 1997 were solicited. From the original sample, 41 patients had expired (44%) and 5 had heart transplants (5%). Two individuals chose not to participate. Twenty-five persons (27%) were not found despite numerous attempts to locate them. The final sample included 21 subjects (22%). Following university institutional review board approval, a mail survey was administered using the Dillman method. Instruments included a demographic data questionnaire, the Psychosocial Adjustment to Illness Scale-Self-Report and the 2-factor version of the Mishel Uncertainty in Illness Scale. The final sample primarily included educated, married, white males. Uncertainty and adjustment levels did not change significantly over time. Early adjustment explained 40% of the variance in overall adjustment at long-term follow-up (P=.010). Men experienced significantly more uncertainty overall [t(19)=2.925, P=.009] and

  4. A bioactive implant in situ and long-term releases combined drugs for treatment of osteoarticular tuberculosis.

    PubMed

    Zhou, Chao-Xi; Li, Litao; Ma, Yi-Guang; Li, Bing-Nan; Li, Guang; Zhou, Zhihang; Shi, Feng; Weng, Jie; Zhang, Cong; Wang, Fenghua; Cui, Xu; Wang, Lei; Wang, Hao

    2018-05-24

    Anti-tuberculosis chemotherapy with a long duration and adequate dosing is the mainstay for treatment of osteoarticular tuberculosis (TB). However, it is difficult for systemic administration to reach adequate local drug concentrations and achieve effective treatment. Herein, a hydroxyapatite (HA) scaffold implant combined with a drug-releasing system was designed to achieve in situ and long-term anti-TB drug release and highly efficient therapeutic activity in vitro and in vivo. The clinical anti-TB drugs hydrophilic isoniazid (INH) and hydrophobic rifampicin (RFP) were molecularly dispersed into polyvinyl alcohol (PVA) through immersion-curing techniques and were steadily adhered onto the surfaces of HA scaffolds (HA-drug@PVA). The HA-drug@PVA scaffolds showed a long-term, sustained drug release profile and killed proliferating Mycobacteriumin vitro. In vivo experimental results revealed that the HA-drug@PVA scaffolds provided over 10- and 100-fold higher concentrations in muscles and bones, respectively, as well as a much lower concentration (<0.025) in blood. Furthermore, the HA-drug@PVA scaffold implanted in an osteoarticular TB rabbit model showed obvious bone regeneration and fusion due to the inhibition of TB-associated inflammatory changes. The excellent therapeutic effects indicate that in situ implant materials combined with a long-term drug release system are promising for the treatment of osteoarticular TB and other osteoarticular infections. Copyright © 2018. Published by Elsevier Ltd.

  5. Long-term outcomes of oral rehabilitation with dental implants in HIV-positive patients: A retrospective case series

    PubMed Central

    Gay-Escoda, Cosme; Pérez-Álvarez, Débora; Camps-Font, Octavi

    2016-01-01

    Background The existing information on oral rehabilitations with dental implants in VIH-positive patients is scarce and of poor quality. Moreover, no long-term follow-up studies are available. Hence, the aims of this study were to describe the long-term survival and success rates of dental implants in a group of HIV-positive patients and to identify the most common postoperative complications, including peri-implant diseases. Material and Methods A retrospective case series of HIV-positive subjects treated with dental implants at the School of Dentistry of the University of Barcelona (Spain) was studied. Several clinical parameters were registered, including CD4 cell count, viral load and surgical complications. Additionally, the patients were assessed for implant survival and success rates and for the prevalence of peri-implant diseases. A descriptive statistical analysis of the data was performed. Results Nine participants (57 implants) were included. The patients’ median age was 42 years (IQR=13.5 years). The implant survival and success rates were 98.3% and 68.4%, respectively, with a mean follow-up of 77.5 months (SD=16.1 months). The patient-based prevalence of peri-implant mucositis and peri-implantitis were 22.2% and 44.4% respectively at the last appointment. Patients that attended regular periodontal maintenance visits had significantly less mean bone loss than non-compliant patients (1.3 mm and 3.9 mm respectively). Conclusions Oral rehabilitation with dental implants in HIV-positive patients seems to provide satisfactory results. In order to reduce the considerably high prevalence of peri-implant diseases, strict maintenance programmes must be implemented. Key words:HIV infection, dental implants, oral implantology, complications, peri-implantitis, peri-implant diseases. PMID:26946205

  6. Long-term outcomes of oral rehabilitation with dental implants in HIV-positive patients: A retrospective case series.

    PubMed

    Gay-Escoda, C; Pérez-Álvarez, D; Camps-Font, O; Figueiredo, R

    2016-05-01

    The existing information on oral rehabilitations with dental implants in VIH-positive patients is scarce and of poor quality. Moreover, no long-term follow-up studies are available. Hence, the aims of this study were to describe the long-term survival and success rates of dental implants in a group of HIV-positive patients and to identify the most common postoperative complications, including peri-implant diseases. A retrospective case series of HIV-positive subjects treated with dental implants at the School of Dentistry of the University of Barcelona (Spain) was studied. Several clinical parameters were registered, including CD4 cell count, viral load and surgical complications. Additionally, the patients were assessed for implant survival and success rates and for the prevalence of peri-implant diseases. A descriptive statistical analysis of the data was performed. Nine participants (57 implants) were included. The patients' median age was 42 years (IQR=13.5 years). The implant survival and success rates were 98.3% and 68.4%, respectively, with a mean follow-up of 77.5 months (SD=16.1 months). The patient-based prevalence of peri-implant mucositis and peri-implantitis were 22.2% and 44.4% respectively at the last appointment. Patients that attended regular periodontal maintenance visits had significantly less mean bone loss than non-compliant patients (1.3 mm and 3.9 mm respectively). Oral rehabilitation with dental implants in HIV-positive patients seems to provide satisfactory results. In order to reduce the considerably high prevalence of peri-implant diseases, strict maintenance programmes must be implemented.

  7. Local and Systemic Changes Associated with Long-term, Percutaneous, Static Implantation of Titanium Alloys in Rhesus Macaques (Macaca mulatta)

    PubMed Central

    Frydman, Galit H; Marini, Robert P; Bakthavatchalu, Vasudevan; Biddle, Kathleen E; Muthupalani, Sureshkumar; Vanderburg, Charles R; Lai, Barry; Bendapudi, Pavan K; Tompkins, Ronald G; Fox, James G

    2017-01-01

    Metal alloys are frequently used as implant materials in veterinary medicine. Recent studies suggest that many alloys induce both local and systemic inflammatory responses. In this study, 37 rhesus macaques with long-term skull-anchored percutaneous titanium alloy implants (duration, 0 to 14 y) were evaluated for changes in their hematology, coagulation, and serum chemistry profiles. Negative controls (n = 28) did not have implants. Macaques with implants had higher plasma D-dimer and lower antithrombin III concentrations than nonimplanted animals. In addition, animals with implants had higher globulin and lower albumin and calcium concentrations compared with nonimplanted macaques. Many of these changes were positively correlated with duration of implantation and the number of implants. Chronic bacterial infection of the skin was present around many of the implant sites and within deeper tissues. Representative histopathology around the implant site of 2 macaques revealed chronic suppurative to pyogranulomatous inflammation extending from the skin to the dura mater. X-ray fluorescence microscopy of tissue biopsies from the implant site of the same 2 animals revealed significantly higher levels of free metal ions in the tissue, including titanium and iron. The higher levels of free metal ions persisted in the tissues for as long as 6 mo after explantation. These results suggest that long-term skull-anchored percutaneous titanium alloy implants can be associated with localized inflammation, chronic infection, and leaching of metal ions into local tissues. PMID:28381317

  8. Development and evaluation of a long-term, implantable, electrically actuated left ventricular assist system: THI/Gould LVAS.

    PubMed

    Norman, J C; McGee, M G; Fuqua, J M; Igo, S R; Turner, S A; Sterling, R; Urrutia, C O; Frazier, O H; Clay, W C; Chambers, J A

    1983-02-01

    A long-term, implantable, electrically actuated left ventricular assist system (THI/Gould LVAS) is being developed and characterized in vitro and in vivo for utilization in patients with end-stage heart disease. This system consists of five major components: a long-term, implantable blood pump (THI E-type ALVAD); an electrical-mechanical energy converter (Gould Model V); a control unit with batteries; a volume compensation system; and an external power supply and monitoring unit. Two of these components (blood pump and electrical-mechanical energy converter) have been integrated, and are undergoing chronic in vivo evaluations in calves. Thus far, 44 pneumatically and electrically actuated THI/Gould LVAS evaluations have been performed. This experience has resulted in greater than 6.5 years of actuation in vivo, with durations exceeding 1 year. System in vivo performance in terms of durability, mechanical reliability, hemodynamic effectiveness, and biocompatibility has been satisfactory. Demonstration of long-term (2-year) effectiveness in supporting the circulation is the ultimate goal.

  9. Early Postimplant Speech Perception and Language Skills Predict Long-Term Language and Neurocognitive Outcomes Following Pediatric Cochlear Implantation

    ERIC Educational Resources Information Center

    Hunter, Cynthia R.; Kronenberger, William G.; Castellanos, Irina; Pisoni, David B.

    2017-01-01

    Purpose: We sought to determine whether speech perception and language skills measured early after cochlear implantation in children who are deaf, and early postimplant growth in speech perception and language skills, predict long-term speech perception, language, and neurocognitive outcomes. Method: Thirty-six long-term users of cochlear…

  10. Biomaterial-host interactions: consequences, determined by implant retrieval analysis.

    PubMed

    Kaplan, S S

    1994-01-01

    Prosthetic biomaterials have had a profound impact on reconstructive surgery but complete biocompatability remains illusive. This review considers the retrieval analysis of four common prosthetic structures: the hip, the knee, heart valves, and blood vessels. We show that despite a fine record of early success, deterioration due to mechanical failure or deleterious host responses to the implant may compromise long term function. The eventual retrieval and detailed analysis of implanted structures provides an invaluable opportunity to determine the characteristics of implant success or failure and to provoke the development of still better materials.

  11. Concept Formation Skills in Long-Term Cochlear Implant Users

    PubMed Central

    Castellanos, Irina; Kronenberger, William G.; Beer, Jessica; Colson, Bethany G.; Henning, Shirley C.; Ditmars, Allison; Pisoni, David B.

    2015-01-01

    This study investigated if a period of auditory sensory deprivation followed by degraded auditory input and related language delays affects visual concept formation skills in long-term prelingually deaf cochlear implant (CI) users. We also examined if concept formation skills are mediated or moderated by other neurocognitive domains (i.e., language, working memory, and executive control). Relative to normally hearing (NH) peers, CI users displayed significantly poorer performance in several specific areas of concept formation, especially when multiple comparisons and relational concepts were components of the task. Differences in concept formation between CI users and NH peers were fully explained by differences in language and inhibition–concentration skills. Language skills were also found to be more strongly related to concept formation in CI users than in NH peers. The present findings suggest that complex relational concepts may be adversely affected by a period of early prelingual deafness followed by access to underspecified and degraded sound patterns and spoken language transmitted by a CI. Investigating a unique clinical population such as early-implanted prelingually deaf children with CIs can provide new insights into foundational brain–behavior relations and developmental processes. PMID:25583706

  12. Long-term clinical outcomes of Ahmed valve implantation in patients with refractory glaucoma.

    PubMed

    Lee, Chang Kyu; Ma, Kyoung Tak; Hong, Young Jae; Kim, Chan Yun

    2017-01-01

    To evaluate the long-term efficacy of intraocular pressure (IOP) reduction and complications of Ahmed Glaucoma Valve (AGV) implantation in patients with refractory glaucoma. Retrospective study. The study involved 302 refractory glaucoma patients who underwent AGV implantation and had a minimum follow-up of 6 months between March 1995 and December 2013. An operation was defined as successful when (1) the postoperative IOP remained between 5 and 21 mmHg and was reduced 30% compared to the baseline IOP with or without medication, (2) there was no loss of light perception or vision-threatening severe complications, and (3) no additional filtering or aqueous drainage surgery was required. Clinical records were reviewed. IOP, anti-glaucoma medications, and complications. The mean follow-up period was 62.25 months (range, 6 to 190 months). The cumulative probability of success was 89% at 6 months, 81% at 1 year, 66% at 3 years, 44% at 10 years, and 26% at 15 years. IOP was reduced from a mean of 32.2 ± 10.5 mmHg to 18.6 ± 9.1 mmHg at 1 month, 15.2 ± 7.0 mmHg at 6 months, and 14.2 ± 3.5 mmHg at 15 years. Surgical failures were significantly increased when preoperative IOP was high, and when severe complications occurred after AGV implantation (P < 0.05). AGV implantation was successful for IOP control in patients with refractive glaucoma in the long term. However, the success rate of surgery decreased over time. Preoperative high IOP and severe complications related to the operation were significant risk factors for failure.

  13. Long-term clinical outcomes of Ahmed valve implantation in patients with refractory glaucoma

    PubMed Central

    Lee, Chang Kyu; Ma, Kyoung Tak; Hong, Young Jae

    2017-01-01

    Purpose To evaluate the long-term efficacy of intraocular pressure (IOP) reduction and complications of Ahmed Glaucoma Valve (AGV) implantation in patients with refractory glaucoma. Design Retrospective study. Subjects The study involved 302 refractory glaucoma patients who underwent AGV implantation and had a minimum follow-up of 6 months between March 1995 and December 2013. Methods An operation was defined as successful when (1) the postoperative IOP remained between 5 and 21 mmHg and was reduced 30% compared to the baseline IOP with or without medication, (2) there was no loss of light perception or vision-threatening severe complications, and (3) no additional filtering or aqueous drainage surgery was required. Clinical records were reviewed. Main outcome measures IOP, anti-glaucoma medications, and complications Results The mean follow-up period was 62.25 months (range, 6 to 190 months). The cumulative probability of success was 89% at 6 months, 81% at 1 year, 66% at 3 years, 44% at 10 years, and 26% at 15 years. IOP was reduced from a mean of 32.2 ± 10.5 mmHg to 18.6 ± 9.1 mmHg at 1 month, 15.2 ± 7.0 mmHg at 6 months, and 14.2 ± 3.5 mmHg at 15 years. Surgical failures were significantly increased when preoperative IOP was high, and when severe complications occurred after AGV implantation (P < 0.05). Conclusion AGV implantation was successful for IOP control in patients with refractive glaucoma in the long term. However, the success rate of surgery decreased over time. Preoperative high IOP and severe complications related to the operation were significant risk factors for failure. PMID:29095931

  14. Zirconia-implant-supported all-ceramic crowns withstand long-term load: a pilot investigation.

    PubMed

    Kohal, Ralf-J; Klaus, Gerold; Strub, Jörg R

    2006-10-01

    The purpose of this pilot investigation was to test whether zirconia implants restored with different all-ceramic crowns would fulfill the biomechanical requirements for clinical use. Therefore, all-ceramic Empress-1 and Procera crowns were cemented on zirconia implants and exposed to the artificial mouth. Afterwards, the fracture strength of the all-ceramic implant-crown systems was evaluated. Conventional titanium implants restored with porcelain-fused-to-metal (PFM) crowns served as controls. Sixteen titanium implants with 16 PFM crowns and 32 zirconia implants with 16 Empress-1 crowns and 16 Procera crowns each--i.e., three implant-crown groups--were used in this investigation. The titanium implants were fabricated using the ReImplant system and the zirconia implants using the Celay system. The upper left central incisor served as a model for the fabrication of the implants and the crowns. Eight samples of each group were submitted to a long-term load test in the artificial mouth (1.2 million chewing cycles). Subsequently, a fracture strength test was performed with seven of the eight crowns. The remaining eight samples of each group were not submitted to the long-term load in the artificial mouth but were fracture-tested immediately. One loaded and one unloaded sample of each group were evaluated regarding the marginal fit of the crowns. All test samples survived the exposure to the artificial mouth. Three Empress-1 crowns showed cracks in the area of the loading steatite ball. The values for the fracture load in the titanium implant-PFM crown group without artificial loading ranged between 420 and 610 N (mean: 531.4 N), between 460 and 570 N (mean: 512.9 N) in the Empress-1 crown group, and in the Procera crown group the values were between 475 and 700 N (mean: 575.7 N) when not loaded artificially. The results when the specimens were loaded artificially with 1.2 million cycles were as follows: the titanium implant-PFM crowns fractured between 440 and 950 N

  15. Long-Term Retrospective Clinical and Radiographic Follow-up of 205 Brånemark System Mk III TiUnite Implants Submitted to Either Immediate or Delayed Loading.

    PubMed

    Imburgia, Mario; Del Fabbro, Massimo

    2015-10-01

    Studies are needed to evaluate long-term performance of immediately loaded implants with moderately rough surface. This retrospective study evaluated long-term survival and periimplant soft and hard tissue conditions in patients treated with TiUnite implants. Forty-one consecutive patients (mean age, 52.6 years) received 205 Brånemark System Mk III TiUnite implants (145 maxillary, 60 mandibular). The indication was single tooth (n = 7 implants), partial (n = 94), or full arches (n = 104). One hundred thirteen implants were immediately loaded. Cumulative survival rate (CSR) of implants was assessed. Long-term marginal bone remodeling, probing pocket depth (PPD), and periimplant mucosa conditions were assessed. Follow-up averaged 8.8 years (range, 6.6-10.6 years). Eight implants in 5 patients failed. CSR was 96.1% (implant basis) and 87.8% (patient basis) up to 10 years. At the longest follow-up, bone loss averaged 0.43 ± 1.15 mm (n = 173), PPD averaged 3.64 ± 0.74 mm, and periimplant mucosa was healthy in 74.6% of cases. Furthermore, 50.3% and 35.5% of implants scored negative for plaque and bleeding, respectively. No significant difference in CSR and hard and soft tissue conditions was found in the long term between immediately and delayed loaded implants. Implants with TiUnite surface demonstrated excellent long-term survival, marginal bone response, and soft tissue conditions, despite a nonoptimal level of oral hygiene.

  16. Long-term moderate elevation of corticosterone facilitates avian food-caching behaviour and enhances spatial memory.

    PubMed

    Pravosudov, Vladimir V

    2003-12-22

    It is widely assumed that chronic stress and corresponding chronic elevations of glucocorticoid levels have deleterious effects on animals' brain functions such as learning and memory. Some animals, however, appear to maintain moderately elevated levels of glucocorticoids over long periods of time under natural energetically demanding conditions, and it is not clear whether such chronic but moderate elevations may be adaptive. I implanted wild-caught food-caching mountain chickadees (Poecile gambeli), which rely at least in part on spatial memory to find their caches, with 90-day continuous time-release corticosterone pellets designed to approximately double the baseline corticosterone levels. Corticosterone-implanted birds cached and consumed significantly more food and showed more efficient cache recovery and superior spatial memory performance compared with placebo-implanted birds. Thus, contrary to prevailing assumptions, long-term moderate elevations of corticosterone appear to enhance spatial memory in food-caching mountain chickadees. These results suggest that moderate chronic elevation of corticosterone may serve as an adaptation to unpredictable environments by facilitating feeding and food-caching behaviour and by improving cache-retrieval efficiency in food-caching birds.

  17. The baric probe: a novel long-term implantable intracranial pressure monitor with ultrasound-based interrogation.

    PubMed

    Limbrick, David D; Lake, Stephen; Talcott, Michael; Alexander, Benjamin; Wight, Samuel; Willie, Jon T; Richard, William D; Genin, Guy M; Leuthardt, Eric C

    2012-12-01

    Prompt diagnosis of shunt malfunction is critical in preventing neurological morbidity and death in individuals with hydrocephalus; however, diagnostic methods for this condition remain limited. For several decades, investigators have sought a long-term, implantable intracranial pressure (ICP) monitor to assist in the diagnosis of shunt malfunction, but efforts have been impeded by device complexity, marked measurement drift, and limited instrumentation lifespan. In the current report, the authors introduce an entirely novel, simple, compressible gas design that addresses each of these problems. The device described herein, termed the "baric probe," consists of a subdural fluid bladder and multichannel indicator that monitors the position of an air-fluid interface (AFI). A handheld ultrasound probe is used to interrogate the baric probe in vivo, permitting noninvasive ICP determination. To assess the function of device prototypes, ex vivo experiments were conducted using a water column, and short- and long-term in vivo experiments were performed using a porcine model with concurrent measurements of ICP via a fiberoptic monitor. Following a toe region of approximately 2 cm H(2)O, the baric probe's AFI demonstrated a predictable linear relationship to ICP in both ex vivo and in vivo models. After a 2-week implantation of the device, this linear relationship remained robust and reproducible. Further, changes in ICP were observed with the baric probe, on average, 3 seconds in advance of the fiberoptic ICP monitor reading. The authors demonstrate "proof-of-concept" and feasibility for the baric probe, a long-term implantable ICP monitor designed to facilitate the prompt and accurate diagnosis of shunt malfunction. The baric probe showed a consistent linear relationship between ICP and the device's AFI in ex vivo and short- and long-term in vivo models. With a low per-unit cost, a reduced need for radiography or CT, and an indicator that can be read with a handheld

  18. Implantable fiber-optic interface for parallel multisite long-term optical dynamic brain interrogation in freely moving mice

    PubMed Central

    Doronina-Amitonova, L. V.; Fedotov, I. V.; Ivashkina, O. I.; Zots, M. A.; Fedotov, A. B.; Anokhin, K. V.; Zheltikov, A. M.

    2013-01-01

    Seeing the big picture of functional responses within large neural networks in a freely functioning brain is crucial for understanding the cellular mechanisms behind the higher nervous activity, including the most complex brain functions, such as cognition and memory. As a breakthrough toward meeting this challenge, implantable fiber-optic interfaces integrating advanced optogenetic technologies and cutting-edge fiber-optic solutions have been demonstrated, enabling a long-term optogenetic manipulation of neural circuits in freely moving mice. Here, we show that a specifically designed implantable fiber-optic interface provides a powerful tool for parallel long-term optical interrogation of distinctly separate, functionally different sites in the brain of freely moving mice. This interface allows the same groups of neurons lying deeply in the brain of a freely behaving mouse to be reproducibly accessed and optically interrogated over many weeks, providing a long-term dynamic detection of genome activity in response to a broad variety of pharmacological and physiological stimuli. PMID:24253232

  19. Implantable fiber-optic interface for parallel multisite long-term optical dynamic brain interrogation in freely moving mice

    NASA Astrophysics Data System (ADS)

    Doronina-Amitonova, L. V.; Fedotov, I. V.; Ivashkina, O. I.; Zots, M. A.; Fedotov, A. B.; Anokhin, K. V.; Zheltikov, A. M.

    2013-11-01

    Seeing the big picture of functional responses within large neural networks in a freely functioning brain is crucial for understanding the cellular mechanisms behind the higher nervous activity, including the most complex brain functions, such as cognition and memory. As a breakthrough toward meeting this challenge, implantable fiber-optic interfaces integrating advanced optogenetic technologies and cutting-edge fiber-optic solutions have been demonstrated, enabling a long-term optogenetic manipulation of neural circuits in freely moving mice. Here, we show that a specifically designed implantable fiber-optic interface provides a powerful tool for parallel long-term optical interrogation of distinctly separate, functionally different sites in the brain of freely moving mice. This interface allows the same groups of neurons lying deeply in the brain of a freely behaving mouse to be reproducibly accessed and optically interrogated over many weeks, providing a long-term dynamic detection of genome activity in response to a broad variety of pharmacological and physiological stimuli.

  20. Clinical and Radiological Long-Term Outcome of a Tapered Implant System with Special Emphasis on the Influence of Augmentation Procedures.

    PubMed

    Schiegnitz, Eik; Al-Nawas, Bilal; Tegner, Alexander; Sagheb, Keyvan; Berres, Manfred; Kämmerer, Peer W; Wagner, Wilfried

    2016-08-01

    Tapered implant designs aim to improve primary stability and implant survival in soft bone. However, respective clinical long-term data are scarce. Therefore, a clinical and radiological evaluation of the long-term success of a transgingival-supracrestal inserted tapered implant system with special emphasis on the influence of augmentation procedures was conducted. In a retrospective study design, all in the Department of Oral and Maxillofacial Surgery of the University Medical Centre, Mainz, Germany, between May 2002 and March 2012, placed tapered implants (Straumann TE®, Basel, Switzerland) were analyzed. In this time period, a total of one hundred ninety-seven tapered implants were inserted in 90 patients. For patients available for clinical recall, success criteria according to Albrektsson and Buser were evaluated. The in situ rate was 96.3% after an average time in situ of 62 ± 31 months. In one hundred twenty-seven sites, bone augmentation procedures were performed. Hereof, 96 sites were sinus augmentation procedures and 31 sites were alveolar ridge augmentations. For patients with sinus augmentation procedures, implant survival was 97.9% and for patients with alveolar ridge augmentations, implant survival was 93.5% after 5 years, indicating a higher implant survival for sinus augmentation, however not statistically different (p = .194). Implant diameter and timing of implant placement had no significant impact on implant survival (p > .05). Mean marginal bone loss was -0.50 ± 1.54 mm for patients receiving maxillary sinus augmentation and -1.16 ± 1.13 mm for patients with alveolar ridge augmentations, indicating a lower marginal bone loss in patients receiving maxillary sinus augmentation (p = .046). Implant success rates ranged between 88% and 92% after a mean follow-up of 6 years. Within the limits of the retrospective character of this study, the tapered soft tissue level implant showed especially in maxillary sinus

  1. Long-term results of hearing preservation cochlear implant surgery in patients with residual low frequency hearing.

    PubMed

    Moteki, Hideaki; Nishio, Shin-Ya; Miyagawa, Maiko; Tsukada, Keita; Iwasaki, Satoshi; Usami, Shin-Ichi

    2017-05-01

    Differences were found between patients with stable hearing and those with progressive hearing loss in the lower frequencies with respect to the rate of progression in the contralateral ear. It is suggested that the electric acoustic stimulation (EAS) can provide improvement in hearing ability over the long-term if residual hearing might be lost to some extent. To evaluate the long-term threshold changes in the low frequency hearing of the implanted ear as compared with the non-implanted ear, and the hearing abilities with EAS along with the extent of residual hearing. Seventeen individuals were enrolled and received the EAS implant with a 24-mm FLEXeas electrode array. Hearing thresholds and speech perception were measured pre- and post-operatively for 1-5 years. Post-operative hearing preservation (HP) rates were calculated using the preservation numerical scale. The average linear regression coefficient for the decline in hearing preservation score was -6.9 for the implanted ear and the patients were subsequently categorized into two groups: those with better than average, stable hearing; and those with worse than average, progressive hearing loss. EAS showed better results than electric stimulation alone, in spite of an absence of speech perception with acoustic stimulation.

  2. Temporary Piggyback Intraocular Lens Implantation Versus Single Intraocular Lens Implantation in Congenital Cataracts: Long-Term Clinical Outcomes.

    PubMed

    Hwang, Sungsoon; Lim, Dong Hui; Lee, Soomin; Choi, Daye Diana; Chung, Eui-Sang; Chung, Tae-Young

    2018-04-01

    To report the long-term results of temporary piggyback IOL implantation in congenital cataract and to compare the clinical outcomes of temporary piggyback IOL with those of single IOL implantation. This is a retrospective, comparative, interventional study. The medical records of all consecutive patients who underwent cataract extraction and single or temporary piggyback IOL implantation within the first 3 years of life from 1999 to 2013 at Samsung Medical Center were reviewed. Twenty-eight eyes from 18 patients underwent single IOL implantation (monopseudophakia group), and 32 eyes of 20 patients underwent temporary piggyback IOL implantation in congenital cataract surgery (polypseudophakia group). The mean age at initial cataract surgery was 15.8 months in the monopseudophakia group and 11.1 months in the polypseudophakia group (P = 0.144). The average follow-up duration was 133 months in the monopseudophakia group and 120 months in the polypseudophakia group (P = 0.391). The best-corrected visual acuity at the last visit was 0.36 logMAR in the monopseudophakia group and 0.55 logMAR in the polypseudophakia group (P = 0.044). Four (14%) and 14 (44%) reoperations for complications within the anterior segment were performed in the monopseudophakia group and polypseudophakia group, respectively (P = 0.042). Four cases (14.3%) in the monopseudophakia group and 13 cases (40.6%) in the polypseudophakia group had a glaucoma-related adverse event (P = 0.086). Compared with primary single IOL implantation in congenital cataract, temporary piggyback IOL implantation produced worse visual acuity, higher reoperation rate, and higher risk of secondary glaucoma. Temporary piggyback IOL implantation does not have benefit in congenital cataract.

  3. Long-Term Visual Outcomes of Secondary Intraocular Lens Implantation in Children with Congenital Cataracts

    PubMed Central

    Jiang, Yongxiang; Lu, Yi

    2015-01-01

    Aim The aim of this study was to evaluate the long-term visual outcomes and factors affecting visual results in children undergoing secondary intraocular lens (IOL) implantation following primary congenital cataract extraction. Methods Children with congenital cataracts who underwent secondary IOL implantation for aphakia at the Eye and ENT Hospital of Fudan University between January 1, 2001, and December 31, 2007, were retrospectively reviewed. One eye was randomly selected in children with bilateral cataracts. Laterality, type of cataract (total or partial opacity), sex, age at primary and secondary surgeries, visual axis opacity (VAO), compliance with amblyopia therapy, postoperative ocular complications, refractive error, ocular alignment, and best corrected visual acuity (BCVA) at last follow-up were recorded; potential factors that might have affected the visual results were evaluated. Results Seventy-six bilateral and 34 unilateral congenital cataract cases were analyzed; the mean ages of the children were 12.70±5.06 and 12.50±2.71 years at final follow-up, the mean follow-up periods from IOL implantation were 94.93±24.22 and 109.09±18.89 months, and the mean BCVA (Log MAR) values were 0.51±0.37 and 1.05±0.46, respectively. Final BCVA after secondary IOL implantation was significantly associated with laterality, type of cataract, age at primary cataract extraction, compliance with amblyopia therapy, and refractive correction after surgery. No significant associations were found between BCVA and sex, age at secondary IOL implantation, VAO, or other ocular complications. The most common ocular complications were VAO and elevated intraocular pressure after surgery. There were no other complications, with the exception of one eye with IOL dislocation. Conclusions The results indicate that the important determinants of long-term visual outcomes in children with congenital cataracts undergoing secondary IOL implantation are laterality, cataract type, age at

  4. Fully Implantable Deep Brain Stimulation System with Wireless Power Transmission for Long-term Use in Rodent Models of Parkinson's Disease.

    PubMed

    Heo, Man Seung; Moon, Hyun Seok; Kim, Hee Chan; Park, Hyung Woo; Lim, Young Hoon; Paek, Sun Ha

    2015-03-01

    The purpose of this study to develop new deep-brain stimulation system for long-term use in animals, in order to develop a variety of neural prostheses. Our system has two distinguished features, which are the fully implanted system having wearable wireless power transfer and ability to change the parameter of stimulus parameter. It is useful for obtaining a variety of data from a long-term experiment. To validate our system, we performed pre-clinical test in Parkinson's disease-rat models for 4 weeks. Through the in vivo test, we observed the possibility of not only long-term implantation and stability, but also free movement of animals. We confirmed that the electrical stimulation neither caused any side effect nor damaged the electrodes. We proved possibility of our system to conduct the long-term pre-clinical test in variety of parameter, which is available for development of neural prostheses.

  5. Long-term results of Ahmed glaucoma valve implantation in Egyptian population

    PubMed Central

    Elhefney, Eman; Mokbel, Tharwat; Abou Samra, Waleed; Kishk, Hanem; Mohsen, Tarek; El-Kannishy, Amr

    2018-01-01

    AIM To evaluate the long-term results and complications of Ahmed glaucoma valve (AGV) implantation in a cohort of Egyptian patients. METHODS A retrospective study of 124 eyes of 99 patients with refractory glaucoma who underwent AGV implantation and had a minimum follow-up of 5y was performed. All patients underwent complete ophthalmic examination and intraocular pressure (IOP) measurement before surgery and at 1d, weekly for the 1st month, 3, 6mo, and 1y after surgery and yearly afterward for 5y. IOP was measured by Goldmann applanation tonometry and/or Tono-Pen. Complications and the number of anti-glaucoma medications needed were recorded. Success was defined as IOP less than 21 mm Hg with or without anti-glaucoma medication and without additional glaucoma surgery. RESULTS Mean age was 23.1±19.9y. All eyes had at least one prior glaucoma surgery. IOP was reduced from a mean of 37.2±6.8 to 19.2±5.2 mm Hg after 5y follow-up with a reduced number of medications from 2.64±0.59 to 1.81±0.4. Complete and qualified success rates were 31.5% and 46.0% respectively at the end of follow-up. The most common complications were encapsulated cyst formation in 51 eyes (41.1%), complicated cataract in 9 eyes (7.25%), recessed tube in 8 eyes (6.45%), tube exposure in 6 eyes (4.8%) and corneal touch in 6 eyes (4.8%). Other complications included extruded AGV, endophthalmitis and persistent hypotony. Each of them was recorded in only 2 eyes (1.6%). CONCLUSION Although refractory glaucoma is a difficult problem to manage, AGV is effective and relatively safe procedure in treating refractory glaucoma in Egyptian patients with long-term follow-up. Encapsulated cyst formation was the most common complication, which limits successful IOP control after AGV implantation. However, effective complications management can improve the rate of success. PMID:29600175

  6. Long-term results of Ahmed glaucoma valve implantation in Egyptian population.

    PubMed

    Elhefney, Eman; Mokbel, Tharwat; Abou Samra, Waleed; Kishk, Hanem; Mohsen, Tarek; El-Kannishy, Amr

    2018-01-01

    To evaluate the long-term results and complications of Ahmed glaucoma valve (AGV) implantation in a cohort of Egyptian patients. A retrospective study of 124 eyes of 99 patients with refractory glaucoma who underwent AGV implantation and had a minimum follow-up of 5y was performed. All patients underwent complete ophthalmic examination and intraocular pressure (IOP) measurement before surgery and at 1d, weekly for the 1 st month, 3, 6mo, and 1y after surgery and yearly afterward for 5y. IOP was measured by Goldmann applanation tonometry and/or Tono-Pen. Complications and the number of anti-glaucoma medications needed were recorded. Success was defined as IOP less than 21 mm Hg with or without anti-glaucoma medication and without additional glaucoma surgery. Mean age was 23.1±19.9y. All eyes had at least one prior glaucoma surgery. IOP was reduced from a mean of 37.2±6.8 to 19.2±5.2 mm Hg after 5y follow-up with a reduced number of medications from 2.64±0.59 to 1.81±0.4. Complete and qualified success rates were 31.5% and 46.0% respectively at the end of follow-up. The most common complications were encapsulated cyst formation in 51 eyes (41.1%), complicated cataract in 9 eyes (7.25%), recessed tube in 8 eyes (6.45%), tube exposure in 6 eyes (4.8%) and corneal touch in 6 eyes (4.8%). Other complications included extruded AGV, endophthalmitis and persistent hypotony. Each of them was recorded in only 2 eyes (1.6%). Although refractory glaucoma is a difficult problem to manage, AGV is effective and relatively safe procedure in treating refractory glaucoma in Egyptian patients with long-term follow-up. Encapsulated cyst formation was the most common complication, which limits successful IOP control after AGV implantation. However, effective complications management can improve the rate of success.

  7. Long-Term Evolution of the Electrical Stimulation Levels for Cochlear Implant Patients

    PubMed Central

    Vargas, Jose Luis; Sainz, Manuel; Roldan, Cristina; de la Torre, Angel

    2012-01-01

    Objectives The stimulation levels programmed in cochlear implant systems are affected by an evolution since the first switch-on of the processor. This study was designed to evaluate the changes in stimulation levels over time and the relationship between post-implantation physiological changes and with the hearing experience provided by the continuous use of the cochlear implant. Methods Sixty-two patients, ranging in age from 4 to 68 years at the moment of implantation participated in this study. All subjects were implanted with the 12 channels COMBI 40+ cochlear implant at San Cecilio University Hospital, Granada, Spain. Hearing loss etiology and progression characteristics varied across subjects. Results The analyzed programming maps show that the stimulation levels suffer a fast evolution during the first weeks after the first switch-on of the processor. Then, the evolution becomes slower and the programming parameters tend to be stable at about 6 months after the first switch-on. The evolution of the stimulation levels implies an increment of the electrical dynamic range, which is increased from 15.4 to 20.7 dB and improves the intensity resolution. A significant increment of the sensitivity to acoustic stimuli is also observed. For some patients, we have also observed transitory changes in the electrode impedances associated to secretory otitis media, which cause important changes in the programming maps. Conclusion We have studied the long-term evolution of the stimulation levels in cochlear implant patients. Our results show the importance of systematic measurements of the electrode impedances before the revision of the programming map. This report also highlights that the evolution of the programming maps is an important factor to be considered in order to determine an adequate calendar fitting of the cochlear implant processor. PMID:23205223

  8. Local and systemic changes associated with long-term, percutaneous, static implantation with titanium alloys in rhesus macaques (Macaca mulatta)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frydman, Galit F.; Marini, Robert P.; Bakthavatchalu, Vasudevan

    Metal alloys are frequently used as implant materials in veterinary medicine. Recent studies suggest that many types of metal alloys may induce both local and systemic inflammatory responses. In this study, 37 rhesus macaques with long-term skull-anchored percutaneous titanium alloy implants (0-14 years duration) were evaluated for changes in their hematology, coagulation and serum chemistry profiles. Negative controls (n=28) did not have implants. All of the implanted animals were on IACUC-approved protocols and were not implanted for the purpose of this study. Animals with implants had significantly higher plasma D-dimer and lower antithrombin III concentrations compared with nonimplanted animals (p-valuesmore » < 0.05). Additionally, animals with implants had significantly higher globulin, and lower albumin and calcium concentrations compared with nonimplanted animals (p-values < 0.05). Many of these changes were positively correlated with duration of implantation as well as the number of implants. Chronic bacterial infection was observed on the skin around many of the implant sites, and within deeper tissues. Representative histopathology around the implant site of two implanted animals revealed chronic suppurative to pyogranulomatous inflammation extending from the skin to the dura mater. X-ray fluorescence microscopy of tissue biopsies from the implant site of the same two animals revealed significant increases in free metal ions within the tissue, including titanium and iron. Free metal ions persisted in the tissues up to 6 months postexplant. These results suggest that long-term skull-anchored percutaneous titanium alloy implants results in localized inflammation, chronic infection, and leaching of metal ions into local tissues.« less

  9. Implantation and Recovery of Long-Term Archival Transceivers in a Migratory Shark with High Site Fidelity

    PubMed Central

    Haulsee, Danielle E.; Fox, Dewayne A.; Breece, Matthew W.; Clauss, Tonya M.; Oliver, Matthew J.

    2016-01-01

    We developed a long-term tagging method that can be used to understand species assemblages and social groupings associated with large marine fishes such as the Sand Tiger shark Carcharias taurus. We deployed internally implanted archival VEMCO Mobile Transceivers (VMTs; VEMCO Ltd. Nova Scotia, Canada) in 20 adult Sand Tigers, of which two tags were successfully recovered (10%). The recovered VMTs recorded 29,646 and 44,210 detections of telemetered animals respectively. To our knowledge, this is the first study to demonstrate a method for long-term (~ 1 year) archival acoustic transceiver tag implantation, retention, and recovery in a highly migratory marine fish. Results show low presumed mortality (n = 1, 5%), high VMT retention, and that non-lethal recovery after almost a year at liberty can be achieved for archival acoustic transceivers. This method can be applied to study the social interactions and behavioral ecology of large marine fishes. PMID:26849043

  10. The long-term use of zygomatic implants: a 10-year clinical and radiographic report.

    PubMed

    Aparicio, Carlos; Manresa, Carolina; Francisco, Karen; Ouazzani, Wafaa; Claros, Pedro; Potau, Josep M; Aparicio, Arnau

    2014-06-01

    The zygoma implant has been an effective option in the short-term management of the atrophic edentulous maxilla. To report on long-term outcomes in the rehabilitation of the atrophic maxilla using zygomatic (ZI) and regular implants (RI). 22 consecutive zygomatic patients in a maintenance program were included. Cumulative survival rate (CSR) of ZI, RI, prostheses, and complications were recorded during, at least, 10 years of loading. Implant mobility was tested using Periotest(®). Sinus health was radiographically and clinically assessed according to Lund-Mackay (L-M) score and Lanza and Kennedy survey, respectively. A satisfaction questionnaire and anatomical measurements were also performed. Patients received 22 prostheses, anchored on 172 implants. Forty-one were ZI. Three RI failed (10 years CSR = 97.71%). Two ZI were partly removed due to perimplant infection (10 years CSR = 95.12%). All patients maintained functional prostheses. One patient fractured framework twice. Loosening or fracturing screws happened in 11 patients. Seven patients fractured occlusal material. Four ZI abutments in two patients were disconnected because of uncomfortable prostheses. Alveolar height at the ZI head level on the right and left sides was 2.64 mm and 2.25 mm, respectively. Mean distance of ZI head center to ridge center, on the right and left sides was 4.54 mm and 5.67 mm, respectively. Mean Periotest values (PTv) of ZI were -4.375 PTv and -4.941 PTv before prostheses placement and after 10 years, respectively. Six patients experienced sinusitis 14-127 months postoperatively. 54.55% of the L-M scores did not present opacification (L-M = 0) in any sinus. Osteomeatal obstruction happened in eight patients (two bilateral). Two (9.09%) were diagnosed with sinusitis. Eighty-four percent reported satisfaction levels above 80%. 31.81% reported maximum satisfaction score (100%). The long-term rehabilitation of the severely atrophic maxillae using ZI is a predictable procedure. © 2012

  11. Myocardial recovery during mechanical circulatory support: long-term outcome and elective ventricular assist device implantation to promote recovery as a treatment goal.

    PubMed

    Dandel, Michael; Hetzer, Roland

    2015-01-01

    Even after incomplete myocardial recovery during mechanical circulatory support, long-term survival rates after ventricular assist device (VAD) explantation can be better than those expected after heart transplantation even for patients with chronic non-ischemic cardiomyopathy as the underlying cause for VAD implantation. The elective therapeutic use of ventricular assist devices for heart failure reversal in its early stage is a future goal. It may be possible to achieve it by developing tools to predict heart failure reversibility even before ventricular assist device implantation and increasing the number of weaning candidates by improvement of adjunctive therapies to optimize unloading-promoted recovery.  Special attention is focused on the long-term stability of cardiac remission after VAD removal, the clinical relevance unloading-promoted myocardial recovery and on the current knowledge about a potential prediction of myocardial recovery during long-term VAD support already before VAD implantation.

  12. EVAHEART: an implantable centrifugal blood pump for long-term circulatory support.

    PubMed

    Yamazaki, Kenji; Kihara, Shinichiro; Akimoto, Takehide; Tagusari, Osamu; Kawai, Akihiko; Umezu, Mitsuo; Tomioka, Jun; Kormos, Robert L; Griffith, Bartley P; Kurosawa, Hiromi

    2002-11-01

    We developed "EVAHEART": a compact centrifugal blood pump system as an implantable left ventricular assist device for long-term circulatory support. The 55 x 64 mm pump is made from pure titanium, and weighs 370 g. The entire blood-contacting surface is covered with an anti-thrombogenic coating of diamond like carbon (DLC) or 2-methacryloyloxyethyl phosphorylcholine (MPC) to improve blood compatibility. Flows exceeding 12 L/min against 100 mmHg pressure at 2600 rpm was measured. A low-temperature mechanical seal with recirculating cooling system is used to seal the shaft. EVAHEART demonstrated an acceptably low hemolysis rate with normalized index of hemolysis of 0.005 +/- 0.002 g/100L. We evaluated the pump in long-term in-vivo experiments with seven calves. Via left thoracotomy, we conducted left ventricular apex-descending aorta bypass, placing the pump in the left thoracic cavity. Pump flow rates was maintained at 5-9 L/min, pump power consumption remained stable at 9-10 W in all cases, plasma free Hb levels were less than 15 mg/dl, and the seal system showed good seal capability throughout the experiments. The calves were sacrificed on schedule on postoperative day 200, 222, 142, 90, 151, 155, and 133. No thrombi formed on the blood contacting surface with either the DLC or MPC coating, and no major organ thromboembolisms occurred except for a few small renal infarcts. EVAHEART centrifugal blood pump demonstrated excellent performance in long-term in-vivo experiments.

  13. New advanced surface modification technique: titanium oxide ceramic surface implants: long-term clinical results

    NASA Astrophysics Data System (ADS)

    Szabo, Gyorgy; Kovacs, Lajos; Barabas, Jozsef; Nemeth, Zsolt; Maironna, Carlo

    2001-11-01

    The purpose of this paper is to discuss the background to advanced surface modification technologies and to present a new technique, involving the formation of a titanium oxide ceramic coating, with relatively long-term results of its clinical utilization. Three general techniques are used to modify surfaces: the addition or removal of material and the change of material already present. Surface properties can also be changed without the addition or removal of material, through the laser or electron beam thermal treatment. The new technique outlined in this paper relates to the production of a corrosion-resistant 2000-2500 A thick, ceramic oxide layer with a coherent crystalline structure on the surface of titanium implants. The layer is grown electrochemically from the bulk of the metal and is modified by heat treatment. Such oxide ceramic-coated implants have a number of advantageous properties relative to implants covered with various other coatings: a higher external hardness, a greater force of adherence between the titanium and the oxide ceramic coating, a virtually perfect insulation between the organism and the metal (no possibility of metal allergy), etc. The coated implants were subjected to various physical, chemical, electronmicroscopic, etc. tests for a qualitative characterization. Finally, these implants (plates, screws for maxillofacial osteosynthesis and dental root implants) were applied in surgical practice for a period of 10 years. Tests and the experience acquired demonstrated the good properties of the titanium oxide ceramic-coated implants.

  14. Long-term success of dental implants in patients with head and neck cancer after radiation therapy.

    PubMed

    Curi, M M; Condezo, A F B; Ribeiro, K D C B; Cardoso, C L

    2018-06-01

    The purpose of this study was to analyze the long-term success and factors potentially influencing the success of dental implants placed in patients with head and neck cancer who underwent radiation therapy with a minimum total dose of 50Gy during the years 1995-2010. Thirty-five patients (169 dental implants) were included in this study. Data on demographic characteristics, tumour type, radiation therapy, implant sites, implant dimensions, and hyperbaric oxygen therapy (HBOT) were obtained from the medical records and analyzed. Implant survival was estimated using Kaplan-Meier survival curves. Seventy-nine dental implants were placed in the maxilla and 90 in the mandible. The mean follow-up after implant installation was 7.4 years (range 0.3-14.7 years). The overall 5-year survival rate for all implants was 92.9%. Sex (P<0.001) and the mode of radiation therapy delivery (P=0.005) had a statistically significant influence on implant survival. Age, time of implantation after irradiation, implant brand and dimensions, and HBOT had no statistically significant influence on implant survival. Osseointegrated dental implants can be used successfully in the oral rehabilitation of patients with head and neck cancer with a history of radiation therapy. Risk factors such as sex and the mode of radiation therapy delivery can affect implant survival. Copyright © 2018 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  15. Evaluation of Autologous Fascia Implantation With Controlled Release of Fibroblast Growth Factor for Recurrent Laryngeal Nerve Paralysis Due to Long-term Denervation.

    PubMed

    Nagai, Hiromi; Nishiyama, Koichiro; Seino, Yutomo; Tabata, Yasuhiko; Okamoto, Makito

    2016-06-01

    Paralyzed tissue due to long-term denervation is resistant to many treatments because it induces irreversible histological changes and disorders of deglutition or phonation. We sought to determine the effect of autologous transplantation of fascia into the vocal fold (ATFV) with controlled release of basic fibroblast growth factor (bFGF) on long-term unilateral vocal fold paralysis (UVFP). Unilateral recurrent laryngeal nerve (RLN) section was performed on 20 rats. Five rats were implanted with autologous fascia only (fascia group), and 10 rats were implanted with autologous fascia and a gelatin hydrogel sheet with 1 μg (1 μg bFGF + fascia group) or 0.1 μg (0.1 μg bFGF + fascia group) of bFGF 4 months after RLN section. We evaluated the normalized glottal gap and laryngeal volume and histological changes 3 months after implantation. The normalized glottal gap was significantly reduced in the 3 fascia implantation groups. Normalized laryngeal volume, fat volume, and lateral thyroarytenoid muscle volume were significantly increased in the 2 fascia implantation with bFGF groups. The ATFV with controlled release of bFGF repaired the glottal gap and laryngeal volume after RLN section and may reduce the occurrence of aspiration and hoarseness. We speculate that this treatment improves laryngeal function in long-term RLN denervation. © The Author(s) 2016.

  16. Long-Term Evaluation of Biotronik Linox and Linox(smart) Implantable Cardioverter Defibrillator Leads.

    PubMed

    Good, Eric D; Cakulev, Ivan; Orlov, Michael V; Hirsh, David; Simeles, John; Mohr, Kelly; Moll, Phil; Bloom, Heather

    2016-06-01

    Expert consensus holds that post-market, systematic surveillance of ICD leads is essential to ensure confirmation of adequate lead performance. GALAXY (NCT00836589) and CELESTIAL (NCT00810264) are ongoing multicenter, prospective, non-randomized registries conducted to confirm the long-term safety and reliability of Biotronik leads. ICD and CRT-D patients are followed for Linox and Linox(smart) ICD lead performance and safety for 5 years post-implant. All procedural and system-related adverse events (AEs) were assessed at each follow-up, along with lead electrical parameters. An independent CEC of EPs adjudicated AEs to determine AE category and lead relatedness. The analysis used categories of lead observations per ISO 5841-2 (Third edition). A total of 3,933 leads were implanted in 3,840 patients (73.0% male, mean age 67.0 ± 12.2 years) at 146 US centers. The estimated cumulative survival probability was 96.3% at 5 years after implant for Linox leads and 96.6% at 4 years after implant for Linox(smart) leads. A comparison of the Linox and Linox(smart) survival functions did not find evidence of a difference (P = 0.2155). The most common AEs were oversensing (23, 0.58%), conductor fracture (14, 0.36%), failure to capture (13, 0.33%), lead dislodgement (12, 0.31%), insulation breach (10, 0.25%), and abnormal pacing impedance (8, 0.20%). Linox and Linox(smart) ICD leads are safe, reliable and infrequently associated with lead-related AEs. Additionally, estimated cumulative survival probability is clinically acceptable and well within industry standards. Ongoing data collection will confirm the longer-term safety and performance of the Linox family of ICD leads. © 2016 Wiley Periodicals, Inc.

  17. Long-term surveillance of zinc implant in murine artery: Surprisingly steady biocorrosion rate.

    PubMed

    Drelich, Adam J; Zhao, Shan; Guillory, Roger J; Drelich, Jaroslaw W; Goldman, Jeremy

    2017-08-01

    Metallic zinc implanted into the abdominal aorta of rats out to 6months has been demonstrated to degrade while avoiding responses commonly associated with the restenosis of vascular implants. However, major questions remain regarding whether a zinc implant would ultimately passivate through the production of stable corrosion products or via a cell mediated fibrous encapsulation process that prevents the diffusion of critical reactants and products at the metal surface. Here, we have conducted clinically relevant long term in vivo studies in order to characterize late stage zinc implant biocorrosion behavior and products to address these critical questions. We found that zinc wires implanted in the murine artery exhibit steady corrosion without local toxicity for up to at least 20months post-implantation, despite a steady buildup of passivating corrosion products and intense fibrous encapsulation of the wire. Although fibrous encapsulation was not able to prevent continued implant corrosion, it may be related to the reduced chronic inflammation observed between 10 and 20months post-implantation. X-ray elemental and infrared spectroscopy analyses confirmed zinc oxide, zinc carbonate, and zinc phosphate as the main components of corrosion products surrounding the Zn implant. These products coincide with stable phases concluded from Pourbaix diagrams of a physiological solution and in vitro electrochemical impedance tests. The results support earlier predictions that zinc stents could become successfully bio-integrated into the arterial environment and safely degrade within a time frame of approximately 1-2years. Previous studies have shown zinc to be a promising candidate material for bioresorbable endovascular stenting applications. An outstanding question, however, is whether a zinc implant would ultimately passivate through the production of stable corrosion products or via a cell mediated tissue encapsulation process that prevented the diffusion of critical

  18. Long-term outcomes after primary failures of artificial urinary sphincter implantation.

    PubMed

    Wang, Rou; McGuire, Edward J; He, Chang; Faerber, Gary J; Latini, Jerilyn M

    2012-04-01

    To assess our institutional outcomes after primary artificial urinary sphincter (AUS) failures. From 1985 to 2010, a total of 149 patients underwent 318 primary and additional AUS procedures. We classified additional procedures as revisions, replacements, or explantations. At a median of 52 months (range, 6-250 months), 53% of patients had required at least 1 additional procedure beyond their initial implantation. These included 106 (63%) revisions, 42 (24.9%) explantations, and 21 (12.4%) replacements. The most common revision was reservoir upsizing (37/106). Reasons for first revision included recurrent incontinence (56.7%), mechanical malfunction (22%), and infection or erosion (18.6%). Explantations were performed primarily for infection and erosion (64.3%). Median time to first revision was 20.1 months (range, 0.1-173 months) after implantation, with a median of 9.5 months (range, 1-102 months) between revisions. Explantation occurred at a median of 22 months (range, 1-221 months) after implant, and subsequent replacement at a median of 33.6 months (range, 2-138 months). At 5 years, 28/83 (33.7%) patients had undergone no additional procedures. Patients with previous radiation were more likely to experience infection (P = .03; OR 3.99; 95% CI 1.03-15.42). Patients with previous myocardial infarction were more likely to experience erosion (P = .04; OR 2.29; 95% CI 1.05-5.02), and obese patients were more likely to experience mechanical malfunction (P = .04; OR 2.62; 95% CI 1.07-6.4). More than half of patients with an AUS will require additional procedures, most likely revision. Radiation, previous myocardial infarction, and obesity are linked to complications. Median time to first revision or explantation is slightly less than 2 years, indicating that long-term follow-up is required after initial implantation. Copyright © 2012 Elsevier Inc. All rights reserved.

  19. Long-term Stability of Soft Tissue Esthetic Outcomes Following Conventional Single Implant Treatment in the Anterior Maxilla: 10-12 Year Results.

    PubMed

    Rokn, A; Bassir, S H; Rasouli Ghahroudi, A A; Kharazifard, M J; Manesheof, R

    2016-01-01

    The present study aimed to evaluate the long-term stability of esthetic outcomes of soft tissue around maxillary anterior single-tooth implants after 10-to-12 years of loading. Patients who had been treated for single-tooth implants in the anterior maxilla between February 2000 and July 2002 were invited to participate in the study. All implants had been placed according to delayed implant placement and conventional loading protocols without any connective tissue graft or papilla preservation flaps. Pink Esthetic Score (PES) was rated using standardized clinical photographs to assess the esthetic outcomes of the implant treatment at the time of crown placement and at time of follow-up examination which was at least 10 years after the crown placement. A total of 19 patients were included. The mean score of PES was 11.63 (SD 1.61; range 7-14) at baseline. After 10-to-12 years of function, a mean PES score of 11.05 (SD 2.09; range 6-14) was recorded. No significant differences were found in the esthetic outcomes, categorized based on clinically relevant levels, between the baseline and follow-up session (p>0.05). Within limitation of the present study, it can be concluded that the esthetic outcomes of soft tissue around the maxillary anterior single-tooth implants placed using conventional implant placement technique remained stable in the long-term.

  20. Long-term prosthetic aftercare of direct vs. indirect attachment incorporation techniques to mandibular implant-supported overdenture.

    PubMed

    Nissan, Joseph; Oz-Ari, Beni; Gross, Ora; Ghelfan, Oded; Chaushu, Gavriel

    2011-06-01

    The aim of this long-term study was to compare the need for prosthetic aftercare of direct vs. indirect attachment incorporation techniques to mandibular implant-supported overdenture. Forty-five consecutive patients were included (130 implants were placed). Treatment was randomly allocated, resulting in 22 patients (group A) to be treated with direct ball attachment incorporation and 23 patients (group B) to be treated with indirect ball attachment incorporation. All patients were treated by experienced oral-maxillofacial surgeons/periodontists and experienced prosthodontists/residents. From the first day that the patients visited the clinic up to 20 years after the first treatment session, all surgical or prosthetic therapeutic interventions were recorded. The recorded data for the present study included the number of aftercare visits and dental treatment received (pressure sores relieve, liner changes due to loss of retention and attachment replacement due to wear). The mean follow-up was 93±57 months. No implants were lost. Statistical analysis revealed a statistically significantly (P<0.001) greater need for prosthetic interventions in group B vs. group A. The mean number of visits dedicated to - pressure sores relieve (7.04±1.4 vs. 3.63±0.84); liner exchange due to loss of retention (3.6±1.3 vs. 1.09±1.06) was significantly higher in group B. Attachment replacement due to wear occurred only in group B (11/23 - 47.8%). The direct technique for attachment incorporation in mandibular implant-supported overdentures using ball attachments is superior to the indirect technique from the aftercare perspective during a long-term evaluation period. © 2010 John Wiley & Sons A/S.

  1. Experiments on the role of deleterious mutations as stepping stones in adaptive evolution

    PubMed Central

    Covert, Arthur W.; Lenski, Richard E.; Wilke, Claus O.; Ofria, Charles

    2013-01-01

    Many evolutionary studies assume that deleterious mutations necessarily impede adaptive evolution. However, a later mutation that is conditionally beneficial may interact with a deleterious predecessor before it is eliminated, thereby providing access to adaptations that might otherwise be inaccessible. It is unknown whether such sign-epistatic recoveries are inconsequential events or an important factor in evolution, owing to the difficulty of monitoring the effects and fates of all mutations during experiments with biological organisms. Here, we used digital organisms to compare the extent of adaptive evolution in populations when deleterious mutations were disallowed with control populations in which such mutations were allowed. Significantly higher fitness levels were achieved over the long term in the control populations because some of the deleterious mutations served as stepping stones across otherwise impassable fitness valleys. As a consequence, initially deleterious mutations facilitated the evolution of complex, beneficial functions. We also examined the effects of disallowing neutral mutations, of varying the mutation rate, and of sexual recombination. Populations evolving without neutral mutations were able to leverage deleterious and compensatory mutation pairs to overcome, at least partially, the absence of neutral mutations. Substantially raising or lowering the mutation rate reduced or eliminated the long-term benefit of deleterious mutations, but introducing recombination did not. Our work demonstrates that deleterious mutations can play an important role in adaptive evolution under at least some conditions. PMID:23918358

  2. Experiments on the role of deleterious mutations as stepping stones in adaptive evolution.

    PubMed

    Covert, Arthur W; Lenski, Richard E; Wilke, Claus O; Ofria, Charles

    2013-08-20

    Many evolutionary studies assume that deleterious mutations necessarily impede adaptive evolution. However, a later mutation that is conditionally beneficial may interact with a deleterious predecessor before it is eliminated, thereby providing access to adaptations that might otherwise be inaccessible. It is unknown whether such sign-epistatic recoveries are inconsequential events or an important factor in evolution, owing to the difficulty of monitoring the effects and fates of all mutations during experiments with biological organisms. Here, we used digital organisms to compare the extent of adaptive evolution in populations when deleterious mutations were disallowed with control populations in which such mutations were allowed. Significantly higher fitness levels were achieved over the long term in the control populations because some of the deleterious mutations served as stepping stones across otherwise impassable fitness valleys. As a consequence, initially deleterious mutations facilitated the evolution of complex, beneficial functions. We also examined the effects of disallowing neutral mutations, of varying the mutation rate, and of sexual recombination. Populations evolving without neutral mutations were able to leverage deleterious and compensatory mutation pairs to overcome, at least partially, the absence of neutral mutations. Substantially raising or lowering the mutation rate reduced or eliminated the long-term benefit of deleterious mutations, but introducing recombination did not. Our work demonstrates that deleterious mutations can play an important role in adaptive evolution under at least some conditions.

  3. Iris-fixated phakic intraocular lens implantation after retinal detachment surgery: long-term clinical results.

    PubMed

    Chung, Jin Kwon; Kim, Jin Kook; Lee, Jae Bum; Lee, Sung Jin

    2013-10-01

    To assess the efficacy and safety of iris-fixated phakic intraocular lens (pIOL) implantation to correct myopia in eyes with previous retinal detachment (RD) surgery. Department of Ophthalmology, Soonchunhyang University College of Medicine, Seoul, South Korea. Retrospective case series. Patients having pIOL implantation in both eyes were enrolled. Eyes that had scleral buckling or encircling (RD group) and healthy fellow eyes (non-RD group) were evaluated over a 6-year follow-up. The corrected distance visual acuity (CDVA), endothelial cell density (ECD), intraoperative complications, and long-term complications were safety outcomes. Uncorrected distance visual acuity (UDVA), predictability, and stability of refraction were efficacy outcomes. The study comprised 34 eyes (17 patients). The mean postoperative CDVA and ECD were not significantly different between groups, and no patient lost CDVA. The rate of transient intraocular pressure spike was significantly higher in the RD group (P=.043). After 3 years and 6 years, the mean postoperative UDVA was 0.06 logMAR ± 0.09 (SD) and 0.08 ± 0.10 logMAR, respectively, in the RD group and 0.04 ± 0.08 logMAR and 0.04 ± 0.09 logMAR, respectively, in the non-RD group (P=.518 and P=.478, respectively). The rate of eyes within ±0.50 diopter of the desired refraction and the postoperative refraction was not significantly different between groups. No eye had vitreoretinal changes requiring secondary surgical intervention. Iris-fixated pIOL implantation corrected the myopic refractive error in patients who had scleral buckling or encircling surgery for RD with a high degree of efficacy, safety, and long-term stability. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  4. Breast implant-associated anaplastic large-cell lymphoma: long-term follow-up of 60 patients.

    PubMed

    Miranda, Roberto N; Aladily, Tariq N; Prince, H Miles; Kanagal-Shamanna, Rashmi; de Jong, Daphne; Fayad, Luis E; Amin, Mitual B; Haideri, Nisreen; Bhagat, Govind; Brooks, Glen S; Shifrin, David A; O'Malley, Dennis P; Cheah, Chan Y; Bacchi, Carlos E; Gualco, Gabriela; Li, Shiyong; Keech, John A; Hochberg, Ephram P; Carty, Matthew J; Hanson, Summer E; Mustafa, Eid; Sanchez, Steven; Manning, John T; Xu-Monette, Zijun Y; Miranda, Alonso R; Fox, Patricia; Bassett, Roland L; Castillo, Jorge J; Beltran, Brady E; de Boer, Jan Paul; Chakhachiro, Zaher; Ye, Dongjiu; Clark, Douglas; Young, Ken H; Medeiros, L Jeffrey

    2014-01-10

    Breast implant-associated anaplastic large-cell lymphoma (ALCL) is a recently described clinicopathologic entity that usually presents as an effusion-associated fibrous capsule surrounding an implant. Less frequently, it presents as a mass. The natural history of this disease and long-term outcomes are unknown. We reviewed the literature for all published cases of breast implant-associated ALCL from 1997 to December 2012 and contacted corresponding authors to update clinical follow-up. The median overall survival (OS) for 60 patients was 12 years (median follow-up, 2 years; range, 0-14 years). Capsulectomy and implant removal was performed on 56 of 60 patients (93%). Therapeutic data were available for 55 patients: 39 patients (78%) received systemic chemotherapy, and of the 16 patients (28%) who did not receive chemotherapy, 12 patients opted for watchful waiting and four patients received radiation therapy alone. Thirty-nine (93%) of 42 patients with disease confined by the fibrous capsule achieved complete remission, compared with complete remission in 13 (72%) of 18 patients with a tumor mass. Patients with a breast mass had worse OS and progression-free survival (PFS; P = .052 and P = .03, respectively). The OS or PFS were similar between patients who received and did not receive chemotherapy (P = .44 and P = .28, respectively). Most patients with breast implant-associated ALCL who had disease confined within the fibrous capsule achieved complete remission. Proper management for these patients may be limited to capsulectomy and implant removal. Patients who present with a mass have a more aggressive clinical course that may be fatal, justifying cytotoxic chemotherapy in addition to removal of implants.

  5. Long-term outcome after implantation of a suprachoroidal cyclosporine drug delivery device in horses with recurrent uveitis.

    PubMed

    Gilger, Brian C; Wilkie, David A; Clode, Allison B; McMullen, Richard J; Utter, Mary E; Komaromy, Andras M; Brooks, Dennis E; Salmon, Jacklin H

    2010-09-01

    To determine the long-term efficacy, complications, and duration of effect of a cyclosporine (CsA) suprachoroidal implant (CSI) in horses with equine recurrent uveitis (ERU). Horses with ERU were treated with a 6-mm diameter, 25 mg, reservoir matrix CsA implant in the deep sclera adjacent to the suprachoroidal space. Horses with follow-up >1 year were examined for frequency of uveitis episodes, complications, and vision at last recheck. Data from 151 eyes of 133 horses from the USA and Europe that had CsA devices implanted for ERU were reviewed. Follow-up time ranged from 13 to 85 months after surgery, with a mean and median follow-up time of 28.9 and 26.3 months, respectively. Overall, at last follow-up 78.8% of eyes were considered visual and the overall mean frequency of uveitis episodes after CSI was 0.09 ± SD 0.08 episodes per month. The most common complications leading to vision loss at last follow-up were persistent uveitis episodes (54%), glaucoma (22%), mature cataracts (16%), and retinal detachment (6%). Persistent uveitis episodes tended to be the highest cause of vision loss in horses with <24 months and >48 months of follow-up. This study demonstrated the long-term maintenance of vision of horses with ERU implanted with a CSI. The increased vision loss related to uveitis episode of inflammation in eyes after the likely depletion of CsA from the CSI suggests that a repeat CSI may be required at or before 48 months after surgery.

  6. [Long-term outcomes of Ahmed glaucoma valve implantation for treating refractory glaucoma].

    PubMed

    Xu, Yumei; Hong, Tao; Li, Wanming

    2015-02-10

    To explore the efficacies and complications of Ahmed glaucoma valve implantation for treating refractory glaucoma. A retrospective study of case series was conducted for 24 patients (26 eyes) with refractory glaucoma from February 2001 to July 2008 at our hospital. Ahmed glaucoma valve implantation was performed. Pre- and post-operative best spectacle-corrected visual acuity (BSCVA), intraocular pressure (IOP), number of medications and complications were recorded and analyzed. The follow-up period was 58-159 months. The post-operative values of IOP were 13.02+/-6.79, 11.43+/-5.24 and 18.56+/-6.43 mmHg at 1 day, 1 month and the last follow-up respectively. There were significant difference when compared with pre-operative IOP (37.59+/-10.76 mmHg, P < 0.01). And 65.38% of eyes maintained or gained ≥ 1 line of BSCVA. But there was no significant difference with pre-operative BSCVA (P = 0.110). Twenty eyes required anti-glaucoma drugs after glaucoma valve implantation and the average number of medication was 1.72+/-0.98. There was significant difference with the pre-operative medication number 2.7 ± 0.7 (P = 0.001). The surgical success rate was 73.1%. And the causes of failure were endophthalmitis, corneal endothelial decompensation, persistent conjunctival wound non-healing, glaucoma valve exposure and loss of light perception.Early postoperative complications were ocular hypotony, shallow anterior chamber, hyphema, transient high IOP and tube occlusion. And long-term complications included encapsulated cyst formation, tube exposure, corneal endothelial decompensation and endophthalmitis. Ahmed glaucoma valve implantation is efficacious for refractory glaucoma.However, clinicians should pay attention to the prevention and treatment of complications.

  7. Long-term Stability of Soft Tissue Esthetic Outcomes Following Conventional Single Implant Treatment in the Anterior Maxilla: 10-12 Year Results

    PubMed Central

    Rokn, A; Bassir, SH; Rasouli Ghahroudi, AA; Kharazifard, MJ; Manesheof, R

    2016-01-01

    Purpose: The present study aimed to evaluate the long-term stability of esthetic outcomes of soft tissue around maxillary anterior single-tooth implants after 10-to-12 years of loading. Methods: Patients who had been treated for single-tooth implants in the anterior maxilla between February 2000 and July 2002 were invited to participate in the study. All implants had been placed according to delayed implant placement and conventional loading protocols without any connective tissue graft or papilla preservation flaps. Pink Esthetic Score (PES) was rated using standardized clinical photographs to assess the esthetic outcomes of the implant treatment at the time of crown placement and at time of follow-up examination which was at least 10 years after the crown placement. Results: A total of 19 patients were included. The mean score of PES was 11.63 (SD 1.61; range 7-14) at baseline. After 10-to-12 years of function, a mean PES score of 11.05 (SD 2.09; range 6–14) was recorded. No significant differences were found in the esthetic outcomes, categorized based on clinically relevant levels, between the baseline and follow-up session (p>0.05). Conclusion: Within limitation of the present study, it can be concluded that the esthetic outcomes of soft tissue around the maxillary anterior single-tooth implants placed using conventional implant placement technique remained stable in the long-term. PMID:27990185

  8. Oral health and oral implant status in edentulous patients with implant-supported dental prostheses who are receiving long-term nursing care.

    PubMed

    Isaksson, Rita; Becktor, Jonas P; Brown, Andrew; Laurizohn, Christer; Isaksson, Sten

    2009-12-01

    The aim of this study was to investigate oral health and oral implant status in a group of edentulous patients receiving long-term residential or nursing care (LTC), all of whom had implant-supported fixed or removable dental prostheses. A dental examination was performed on a total of 3310 patients receiving LTC and from this population 35 edentulous patients in whom dental implants had been placed formed the cohort for this study. All examinations were performed by a specialist in hospital dentistry and took place in the patients' own home environment. Oral health was assessed by means of a protocol which evaluated oral hygiene status, possible oral mucosal inflammation and oral mucosal friction levels. Any problems with the implant-supported prosthesis, implant mobility or other complications were also assessed. In addition, patients were asked about any oral symptoms and their usual oral hygiene procedures. About half of the subjects (17/35) were registered as having no/mild inflammation with 18 of 35 having moderate/severe inflammation. Twelve of the 35 patients had good/acceptable oral hygiene and 23 of 35 had poor/bad oral hygiene. Twenty-one of the 35 patients depended on help from the nursing personnel for their daily oral hygiene procedures. Obvious problems with food impaction were noted in 11 patients. A total of 229 implants had been placed in 43 jaws supporting 40 full arch-fixed prostheses and three implant-borne overdentures. There was no evidence of mobility or fractures of either the implants or the prostheses. Fifteen implants showed some exposed screw threads. Pus was exuding from one implant site and general peri-implant gingival hyperplasia was noted in two patients. Twenty-four patients were completely satisfied with the function and appearance of their implant-supported prostheses. Two patients were totally dissatisfied. This study indicates that oral implant therapy can be considered as a treatment of choice in elderly patients, even if

  9. Long-term Outcome of Peripherally Implanted Venous Access Ports in the Forearm in Female Cancer Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klösges, Laura, E-mail: l.kloesges@uni-bonn.de; Meyer, Carsten, E-mail: carsten.meyer@ukb.uni-bonn.de; Boschewitz, Jack, E-mail: jack.boschewitz@ukb.uni-bonn.de

    PurposeThe aim of this retrospective study was to analyze the long-term outcome of peripherally implanted venous access ports in the forearm at our institution in a female patient collective.MethodsBetween June 2002 and May 2011, a total of 293 female patients with an underlying malignancy had 299 forearm ports implanted in our interventional radiology suite. The mean age of the cohort was 55 ± 12 years (range 26–81 years). The majority of women suffered from breast (59.5 %) or ovarian cancer (28.1 %). Complications were classified as infectious complications, thrombotic and nonthrombotic catheter dysfunction (dislocation of the catheter or port chamber, fracture with/without embolization or kinking ofmore » the catheter, port occlusion), and others.ResultsWe analyzed a total of 90,276 catheter days in 248 port systems (47 patients were lost to follow-up). The mean device service interval was 364 days per catheter (range 8–2,132, median 223 days, CI 311–415, SD 404). Sixty-seven early (≤30 days from implantation) or late complications (>30 days) occurred during the observation period (0.74/1,000 catheter days). Common complications were port infection (0.18/1,000 days), thrombotic dysfunction (0.12/1,000 days), and skin dehiscence (0.12/1,000 days). Nonthrombotic dysfunction occurred in a total of 21 cases (0.23/1,000 days) and seemed to cumulate on the venous catheter entry site on the distal upper arm.ConclusionPeripherally implanted venous access ports in the forearm are a safe alternative to chest or upper-arm ports in female oncology patients. Special attention should be paid to signs of skin dehiscence and nonthrombotic dysfunction, especially when used for long-term treatment.« less

  10. [Implantation of the paclitaxel-eluting stent Apollo in patients with stable angina pectoris: long-term angiographic and clinical results].

    PubMed

    Batyraliev, T A; Fettser, D V; Samko, A N; Sidorenko, B A

    2010-01-01

    to assess the long-term angiographic and clinical results of percutaneous coronary interventions (PCI) with implantation of the drug-eluting stent (DES) Apollo in patients with stable angina pectoris. The study enrolled 48 patients with stable angina who had been implanted with 59 stents. A follow-up of the patients lasted 12 months. The intervention was successful in 100% patients. Following 12 months, 81.3% of the patients underwent angiography that demonstrated that the vascular diameter decreased by 0.32 +/- 0.45 mm and the rate of restenosis was reduced by only 5.3%. The frequency of evident cardiac complications over 12 months was as high as 11.6%. The DES Apollo provides a way of safely performing PCI, by achieving a high of angiographic success rate. The application of this stent yields long-term good angiographic and clinical results in patients with stable angina pectoris.

  11. Long-Term Outcomes, Education, and Occupational Level in Cochlear Implant Recipients Who Were Implanted in Childhood.

    PubMed

    Illg, Angelika; Haack, Marius; Lesinski-Schiedat, Anke; Büchner, Andreas; Lenarz, Thomas

    To document the long-term outcomes of auditory performance, educational status, vocational training, and occupational situation in users of cochlear implants (CIs) who were implanted in childhood. This retrospective cross-sectional study of 933 recipients of CIs examined auditory performance, education and vocational training, and occupational outcomes. All participants received their first CI during their childhood between 1986 and 2000. Speech comprehension results were categorized using the categories of auditory performance (CAP) arranged in order of increasing difficulty ranging from 0 to 8. 174 of the 933 pediatric recipients of CIs completed a self-assessment questionnaire regarding their education and occupational outcomes. To measure and compare school education, qualifications were converted into International Standard Classification of Education levels (ISCED-97). Occupations were converted into International Standard Classification of Occupation-88 skill levels. Data from the German General Social Survey (Allgemeine Bevölkerungsumfrage der Sozialwissenschaften/ALLBUS) for 2012 were used as a basis for comparing some of the collected data with the general population in Germany. The results showed that 86.8% of the 174 participants who completed the survey used their devices more than 11 hr per day. Only 2% of the surveyed individuals were nonusers. Median CAP was 4.00 (0 to 8). Age at implantation was significantly correlated with CAP level (r = -0.472; p < 0.001). The mean ISCED level of the 174 surveyed recipients was 2.24 (SD = 0.59; range: 1 to 3). A significant difference (p = 0.001) between users' ISCED levels and those of respondents was found. Participants' ISCED levels and maternal educational levels were significantly correlated (r = 0.271; p = 0.008). The International Standard Classification of Occupation-88 skill levels were as follows: 5% achieved skill level 1; 77% skill level 2; 16% skill level 3; and 5% skill level 4. The average

  12. Role of fluconazole in the long-term suppressive therapy of fungal infections in patients with artificial implants.

    PubMed

    Penk, A; Pittrow, L

    1999-12-01

    With the increased use of artificial implants the management of related infections has become an important challenge. Normally an infected implant would be removed. In many cases this might be contraindicated and drug treatment remains as the only alternative. As microbiological eradication is often impossible, especially in fungal infections at artificial implants (FIAI) long-term suppressive therapy might be required. The objective of this study was to determine the therapeutic value of fluconazole (F) in the management of FIAI. Clinical data of 56 patients (pts) with proven or suspected fungal infections and artificial implants (FIAI) subsequently treated with F were analyzed retrospectively. FIAI caused by species with intrinsic resistance to F have been excluded from the study. The following implants were involved: prosthetic valve endocarditis (PVE) 25 pts (44.6%), intraocular lenses (IL) 9 pts (16.1%), ventriculoperitoneal shunts (VPS) 6 pts (10.7%), knee prostheses (KP) 5 pts (8.9%), biliary stents (BS) 4 pts (7.1 %), venous access devices (VAS) 3 pts (5.4%), urinary stents (US) 2 pts (3.6%), breast implant and pacemaker 1 patient (1.8%) each. Underlying diseases were valve insufficiency (in PVE), cataract surgery (in IL), prematurity in newborns (in VPS), arthrosis (in KP), biliary obstruction (in BS), cystic fibrosis (in VAS), and obstructive renal calculi (in US). Candida species (C. spp.) were the most frequently detected causative agents with C. parapsilosis as the leading cause (n = 19; 33.9%). Furthermore C. albicans (n = 15; 26.8%), C. spp. and fungi not further specified (n = 8; 14.3%), C. tropicalis (n = 3; 5.4%), C. glabrata (n = 3; 5.4%), and C. lusitaniae (n = 1; 1.8%) were identified. Acremonium kiliense has been detected in 4 pts (7.1%), Cryptococcus neoformans in 2 pts (3.6 %). Histoplasma capsulatum was identified in 1 patient (1.8%). The maximum duration of treatment with F was lifelong with a maximum recorded duration of 4,5 years. The

  13. Long-term outcome in patients receiving permanent pacemaker implantation for atrioventricular block: Comparison of VDD and DDD pacing.

    PubMed

    Liao, Jo-Nan; Chao, Tze-Fan; Tuan, Ta-Chuan; Kong, Chi-Woon; Chen, Shih-Ann

    2016-08-01

    A permanent pacemaker (PPM) with dual chamber pacing (DDD) offers atrioventricular synchronization for patients with atrioventricular block (AVB). Single lead atrial synchronous ventricular pacing mode (VDD) is an alternative, but there are concerns about its efficacy and risk of atrial undersensing. Whether VDD can be a good alternative in patients with AVB remains unknown. The aim of the present study was to compare the long-term risk of mortality of VDD with DDD pacing.A total of 207 patients undergoing PPM implantations for AVB with VDD mode were enrolled from 2000 to 2013. Another 828 age- and sex-matched patients undergoing DDD implantations during the same period of time were selected as the control group in a 1 to 4 ratio. The study endpoint was mortality.A total of 1035 patients (64.3% male) were followed up for 46.5 ± 43.2 months. The mean ages were 75.0 years for VDD, and 74.9 years for DDD. The Kaplan-Meier survival analysis showed no significant difference in long-term survival between the VDD and DDD groups (log-rank P = 0.313). After adjustment for baseline characteristics, the VDD and DDD groups had a similar long-term prognosis with an adjusted hazard ratio of 0.875 (P = 0.445). Further analyses for the risk of cardiovascular and noncardiovascular deaths also showed no significant differences between the 2 groups.The long-term prognosis of VDD mode is comparable to that of DDD mode. Single lead VDD can be considered as an alternative choice in patients with AVB without sinus nodal dysfunction.

  14. Short-term to Long-term Results of Ahmed Glaucoma Valve Implantation for Uveitic Glaucoma Secondary to Behçet Disease.

    PubMed

    Yakin, Mehmet; Eksioglu, Umit; Sungur, Gulten; Satana, Banu; Demirok, Gulizar; Ornek, Firdevs

    2017-01-01

    To evaluate short-term to long-term outcomes of Ahmed glaucoma valve (AGV) implantation in the management of uveitic glaucoma (UG) secondary to Behçet disease (BD). A retrospective chart review of 47 eyes of 35 patients with UG secondary to BD who underwent AGV implantation was conducted. Success was defined as having an intraocular pressure (IOP) between 6 and 21 mm Hg with (qualified success) or without (complete success) antiglaucomatous medications and without need for further glaucoma surgery. Mean postoperative follow-up was 57.72±26.13 months. Mean preoperative IOP was 35.40±8.33 mm Hg versus 12.28±2.90 mm Hg at the last follow-up visit (P<0.001). Mean number of preoperative topical antiglaucomatous medications was 2.96±0.29 versus 0.68±1.12 at the last follow-up visit (P<0.001). In all eyes, IOP could be maintained between 6 and 21 mm Hg with or without antiglaucomatous medications during follow-up. The cumulative probability of complete success was 46.8% at 6 months, 40.4% at 12 months, and 35.9% at 36 months, and the cumulative probability of eyes without complication was 53.2% at 6 months, 46.5% at 12 months, and 39.6% at 24 months postoperatively based on Kaplan-Meier survival analysis. No persistent or irreparable complications were observed. This study includes one of the largest series of AGV implantation in the management of UG with the longest follow-up reported. AGV implantation can be considered as a primary surgical option in the management of UG secondary to BD with 100% total success rate (with or without medications).

  15. Long-Term Survival With Implantable Cardioverter-Defibrillator in Different Symptomatic Functional Classes of Heart Failure.

    PubMed

    Biton, Yitschak; Rosero, Spencer; Moss, Arthur; Zareba, Wojciech; Kutyifa, Valentina; Baman, Jayson; Barsheshet, Alon; McNitt, Scott; Polonsky, Bronislava; Goldenberg, Ilan

    2018-03-01

    The ACC/AHA/HRS (American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society) guidelines recommend implantable cardioverter-defibrillator (ICD) therapy primary prevention in all patients with severely reduced left ventricular ejection fraction (≤30%) regardless of New York Heart Association (NYHA) functional class, whereas recent European guidelines limit the indication to those with symptomatic heart failure (NYHA ≥ II). We therefore aimed to evaluate the long-term survival benefit of primary ICD therapy among postmyocardial infarction patients with and without heart failure (HF) symptoms who were enrolled in MADIT-II (Multicenter Automatic Defibrillator Implantation Trial II). We classified 1,164 MADIT-II patient groups according to the baseline NYHA class (NYHA I [n = 442], NYHA II [n = 425], and NYHA III [n = 297]); patients with NYHA IV were excluded. Multivariate Cox proportional hazards regression modeling was performed to compare the mortality reduction with ICD versus non-ICD therapy during 8 years of follow-up between the 3 NYHA groups. The median (interquartile range) follow-up time was 7.6 (3.5 to 9) years. At 8 years of follow-up, the cumulative probability of mortality in the non-ICD treatment arm was 57% for NYHA I, 57% for NYHA II, and 76% for NYHA III (p <0.001). Multivariate models demonstrated similar long-term mortality risk reduction with ICD compared with the non-ICD treatment arm regardless of HF symptoms: NYHA I (HR = 0.63, 0.46 to 0.85, p = 0.003), NYHA II (HR = 0.68, 0.50 to 0.93, p = 0.017), and NYHA III (HR = 0.68, 0.50 to 0.94, p = 0.018); p for NYHA class by treatment arm interaction >0.10. In conclusion, primary ICD therapy provides consistent long-term survival benefit among patients with previous myocardial infarction and severe left ventricular dysfunction, regardless of HF symptoms. Copyright © 2017 Elsevier Inc

  16. Long-term outcome of accelerated partial breast irradiation using a multilumen balloon applicator in a patient with existing breast implants.

    PubMed

    Akhtari, Mani; Nitsch, Paige L; Bass, Barbara L; Teh, Bin S

    2015-01-01

    Accelerated partial breast irradiation is now an accepted component of breast-conserving therapy. However, data regarding long-term outcomes of patients treated with multilumen catheter systems who have existing breast implants are limited. We report the treatment and outcome of our patient who had existing bilateral silicone subpectoral implants at the time of presentation. Ultrasound-guided core needle biopsy of the right breast showed infiltrating mucinous carcinoma. Right breast lumpectomy revealed an 8 mm area of infiltrating ductal carcinoma with mucinous features and nuclear grade 1. A 4-5 cm Contura (Bard Biopsy Systems, Tempe, AZ) device was placed, and she was treated over the course of 5 days twice daily to a dose of 34 Gy using a high-dose-rate iridium-192 source. The planning target volume for evaluation was 73.9 cc. The percentage of the planning target volume for evaluation receiving 90%, 95%, and 100% of the prescribed dose was 99.9%, 99.3%, and 97.8%, respectively. The total implant volume was 234.5 cc and received a mean dose of 15.4 Gy and a maximum dose of 72.8 Gy. The percentage of implant volume receiving 50%, 75%, 100%, and 200% of the prescribed dose was 31.1%, 16.5%, 8.6%, 2.0%, and 0%, respectively. Maximum skin dose was 97% of the prescribed dose. With a followup of nearly 5 years, she continues to be cancer free with minimal late toxicities and good to excellent cosmetic outcome. Accelerated partial breast irradiation using a multilumen balloon applicator in patients with existing breast implants can safely be performed with excellent long-term cosmetic outcome. Further studies are needed to establish the absolute dosimetric tolerance of breast implants. Copyright © 2015 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  17. Parylene-on-oil packaging for long-term implantable pressure sensors.

    PubMed

    Shapero, Aubrey M; Liu, Yang; Tai, Yu-Chong

    2016-08-01

    This paper reports and analyzes the feasibility study of a parylene-on-oil encapsulation packaging method of pressure sensors targeted for long-term implantation. Commercial barometric digital-output pressure sensors are enclosed in silicone oil and then encapsulated in situ with parylene-C or -D (PA-C, PA-D) chemical vapor deposition. Experimentally, sensors encapsulated with 30,000 cSt silicone oil and 27 μm PA-D show good performance for 6 weeks in 77 °C saline with >99 % of original sensitivity, corresponding to an extrapolated lifetime of around 21 months in 37 °C saline. This work shows that, with proper designs, such a packaging method can preserve the original pressure sensor sensitivity without offset, validated throughout accelerated lifetime tests. In experiments, wires on the prototypes are used for external electronics but it is found that they contributed to early failures, which would be absent in real wireless versions, indicating a potential for even longer lifetimes. Finally, a verified model is presented to predict the pressure sensor sensitivity of parylene-on-oil packaging with and without the presence of a bubble in the oil.

  18. Long-term visual outcomes and patient satisfaction following bilateral implantation of trifocal intraocular lenses

    PubMed Central

    Ganesh, Sri; Brar, Sheetal; Pawar, Archana

    2017-01-01

    Purpose To study the long-term visual and refractive outcomes and evaluate patient satisfaction after bilateral implantation of trifocal intraocular lenses (IOLs). Setting Nethradhama Superspeciality Eye Hospital, Bangalore. Design Prospective, nonrandomized study. Methods Eligible patients undergoing bilateral phacoemulsification with trifocal IOL implantation were included. Follow-up examinations were conducted at day 1, 1 week, 1 month, 6 months, and 12 months. Postoperatively, 1 month onward evaluation of uncorrected and distance-corrected far and near visual acuity; reading acuity and reading speeds (using Salzburg Reading Desk) at 70, 80, and 90 cm; contrast sensitivity; defocus curves; and patient satisfaction was carried out. Results Fifty eyes from 25 patients with a mean age of 58±13.44 years were included. All eyes showed significant improvement in spherical equivalent, uncorrected distance visual acuity, corrected distance visual acuity, uncorrected near visual acuity, and corrected near visual acuity at 1 month compared to preoperative values (P<0.05), with no significant change in these parameters thereafter until the last follow-up (P>0.05). At 12 months, mean uncorrected reading acuities and reading speeds at 70, 80, and 90 cm were in the range of 0.09–0.04 logMAR units and 153.6–169.0 words per minute, respectively, with significantly better results at 80 cm. Five eyes underwent YAG laser capsulotomy for early posterior capsule opacification (PCO) at a mean follow-up of 7.2±2.9 months. Contrast sensitivity scores at 12 months were comparable to 1 month (P>0.05 for all spatial frequencies). All patients reported good tolerance and 100% independence from spectacles for all activities. Conclusion Trifocal IOLs provided excellent unaided vision at all distances. Reading performance was good through the complete intermediate distance range. PCO occurrence and subsequent YAG capsulotomy did not affect the long-term visual outcomes. PMID:28860693

  19. Thirteen-year nationwide trends in use of implantable cardioverter-defibrillators and subsequent long-term survival.

    PubMed

    Schmidt, Morten; Pedersen, Susanne Bendesgaard; Farkas, Dóra Körmendiné; Hjortshøj, Søren Pihlkjær; Bøtker, Hans Erik; Nielsen, Jens Cosedis; Sørensen, Henrik Toft

    2015-09-01

    Long-term trends in use of implantable cardioverter-defibrillators (ICDs) and outcomes are rare. We examined 13-year nationwide trends in ICD implantation and survival rates in Denmark. Using medical databases, we identified all first time ICD recipients in Denmark during 2000-2012 (N = 8460) and ascertained all-cause mortality. We computed standardized annual implantation rates and mortality rate ratios according to age, sex, comorbidity level, indication, and device type. The standardized annual implantation rate increased from 42 per million persons in 2000 to 213 per million persons in 2012 (from 34 to 174 for men and from 8 to 39 for women). The increase was driven by secondary prophylactic ICDs until 2006 and primary prophylactic ICDs thereafter. The increase occurred particularly in older patients and those with a high level of comorbidity. Independent of indication, 76% of all patients with ICD were alive after 5 years. Men had a higher mortality rate compared with women (mortality rate ratio 1.28; 95% confidence interval 1.10-1.49). Compared with low comorbidity level, moderate, severe, and very severe comorbidity levels were associated with 1.6-, 2.5-, and 4.9-fold increased mortality rates, respectively. The most influential individual comorbidities were heart failure, diabetes, liver disease, and renal disease. The annual implantation rate of ICDs increased 5-fold in Denmark between 2000 and 2012. The rate increase occurred for both men and women, but particularly in the elderly and patients with severe comorbidity. Five-year survival probability was high, but severe comorbidity and male sex were associated with shorter survival. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  20. Long-term survival of donor bone marrow multipotent mesenchymal stromal cells implanted into the periosteum of patients with allogeneic graft failure.

    PubMed

    Kuzmina, L A; Petinati, N A; Sats, N V; Drize, N J; Risinskaya, N V; Sudarikov, A B; Vasilieva, V A; Drokov, M Y; Michalzova, E D; Parovichnikova, E N; Savchenko, V G

    2016-09-01

    The present study involved three patients with graft failure following allogeneic hematopoietic stem cell transplantation (allo-HSCT). We obtained multipotent mesenchymal stromal cells (MSCs) from the original hematopoietic cell donors and implanted these cells in the periosteum to treat long-term bone marrow aplasia. The results showed that in all patients endogenous blood formation was recovered 2 weeks after MSC administration. Donor MSCs were found in recipient bone marrow three and 5 months following MSC implantation. Thus, our findings indicate that functional donor MSCs can persist in patient bone marrow.

  1. Long-Term Experience with First-Generation Implantable Neurostimulation Device in Central Sleep Apnea Treatment.

    PubMed

    Fox, Henrik; Bitter, Thomas; Horstkotte, Dieter; Oldenburg, Olaf; Gutleben, Klaus-Jürgen

    2017-05-01

    Sleep-disordered breathing (SDB) and Cheyne-Stokes respiration (CSR) are associated with shorter survival in patients with heart failure. A novel treatment method for this patient group is unilateral phrenic nerve stimulation by the remedē® system (Respicardia Inc., Minnetonka, MN, USA), a transvenously implantable neurostimulation device, which has recently been studied in a large randomized, controlled trial. Previous literature has shown efficacy and safety of the treatment with this first-generation device, but hardly any data are available on long-term clinical parameters, the remedē® device's battery lifetime, device exchangeability, lead position stability, surgical accessibility, and manageability. We performed remedē® device replacements in consecutive patients for battery depletion, and documented clinical parameters, longevity, operation procedure, complications, and difficulties. All patients were on neurostimulation treatment by phrenic nerve neurostimulation when device replacement became necessary. Apnea-hypopnea index (from 45 ± 4/h to 9 ± 4/h), oxygen-desaturation index (from 35 ± 7/h to 7 ± 6/h), and time spent with oxygen saturation of <90% (T < 90% from 5 ± 7% to 0 ± 0%) were improved and improvements remained constant throughout the 4-year follow-up. Mean battery life was 4.2 ± 0.2 years and mean replacement procedure time was 25 ± 5.1 minutes. Apart from conventional X-ray documentation of stable lead positions in a long-term setting, no radiation or contrast dye usage was needed and no major complications occurred. In addition, clinical exercise capacity and sleepiness symptoms improved. Novel remedē® device shows sustained therapy efficacy and safety in terms of stable lead positions over 4 years. Long-term phrenic nerve neurostimulation therapy for central SDB/CSR appears feasible in a clinical routine setting. © 2017 Wiley Periodicals, Inc.

  2. Executive Functioning Skills in Long-Term Users of Cochlear Implants: A Case Control Study

    PubMed Central

    Pisoni, David B.; Henning, Shirley C.; Colson, Bethany G.

    2013-01-01

    Objective To investigate differences in executive functioning between deaf children with cochlear implants (CIs) and normal-hearing (NH) peers. The cognitive effects of auditory deprivation in childhood may extend beyond speech–language skills to more domain-general areas including executive functioning. Methods Executive functioning skills in a sample of 53 prelingually deaf children, adolescents, and young adults who received CIs prior to age 7 years and who had used their CIs for ≥7 years were compared with age- and nonverbal IQ-matched NH peers and with scale norms. Results Despite having above average nonverbal IQ, the CI sample scored lower than the NH sample and test norms on several measures of short-term/working memory, fluency–speed, and inhibition–concentration. Executive functioning was unrelated to most demographic and hearing history characteristics. Conclusions Prelingual deafness and long-term use of CIs was associated with increased risk of weaknesses in executive functioning. PMID:23699747

  3. Long term outcomes of transcatheter aortic valve implantation (TAVI): a systematic review of 5-year survival and beyond.

    PubMed

    Chakos, Adam; Wilson-Smith, Ashley; Arora, Sameer; Nguyen, Tom C; Dhoble, Abhijeet; Tarantini, Giuseppe; Thielmann, Matthias; Vavalle, John P; Wendt, Daniel; Yan, Tristan D; Tian, David H

    2017-09-01

    Transcatheter aortic valve implantation/replacement (TAVI/TAVR) is becoming more frequently used to treat aortic stenosis (AS), with increasing push for the procedure in lower risk patients. Numerous randomized controlled trials have demonstrated that TAVI offers a suitable alternative to the current gold standard of surgical aortic valve replacement (SAVR) in terms of short-term outcomes. The present review evaluates long-term outcomes following TAVI procedures. Literature search using three electronic databases was performed up to June 2017. Studies which included 20 or more patients undergoing TAVI procedures, either as a stand-alone or concomitant procedure and with a follow-up of at least 5 years, were included in the present review. Literature search and data extraction were performed by two independent researchers. Digitized survival data were extracted from Kaplan-Meier curves in order to re-create the original patient data using an iterative algorithm and subsequently aggregated for analysis. Thirty-one studies were included in the present analysis, with a total of 13,857 patients. Two studies were national registries, eight were multi-institutional collaborations and the remainder were institutional series. Overall, 45.7% of patients were male, with mean age of 81.5±7.0 years. Where reported, the mean Logistic EuroSCORE (LES) was 22.1±13.7 and the mean Society of Thoracic Surgeons (STS) score was 9.2±6.6. The pooled analysis found 30-day mortality, cerebrovascular accidents, acute kidney injury (AKI) and requirement for permanent pacemaker (PPM) implantation to be 8.4%, 2.8%, 14.4%, and 13.4%, respectively. Aggregated survival at 1-, 2-, 3-, 5- and 7-year were 83%, 75%, 65%, 48% and 28%, respectively. The present systematic review identified acceptable long-term survival results for TAVI procedures in an elderly population. Extended follow-up is required to assess long-term outcomes following TAVI, particularly before its application is extended into

  4. [Long-term results of posterior chamber phakic intraocular lens implantation for correction of high ametropia].

    PubMed

    Le Loir, M; Cochener, B

    2012-06-01

    To assess efficacy, stability and safety of posterior chamber phakic intraocular lens implantation with STAAR Visian ICL for correction of high ametropia, with a mean follow-up of 5 years (3.5-10 years). Ninety eyes of 53 highly ametropic patients (45 myopia, ten hyperopia and 35 with mixed astigmatism) were included in a retrospective single-surgeon study, using primarily the V4 ICL model (87 eyes). We studied pre- and postoperative refractive efficacy, endothelial cell density, crystalline lens opacification and intraocular clearances within the various compartments of the eye. Mean uncorrected visual acuity was 0.77 at the 12th postoperative month; 17 of 90 eyes required adjunctive photoablation for residual astigmatism. Forty-eight percent of eyes gained at least one line of best corrected visual acuity. After implantation, the decrease in endothelial cell density remained stable at 0.69%/year, and 91% of eyes showed no opacification of the crystalline lens. Mean endothelium-ICL and ICL-crystalline lens distances were 2.41 mm and 0.52 mm respectively. Overall patient satisfaction achieved was 96% at 36 months postoperatively. These results demonstrate efficacy, stability and safety of the ICL V4 phakic IOL for the correction of high ametropia. Long-term follow-up did not show a significant increase in cataract formation in implanted eyes. Copyright © 2012. Published by Elsevier Masson SAS.

  5. Long-term amnioinfusion through a subcutaneously implanted amniotic fluid replacement port system for treatment of PPROM in humans.

    PubMed

    Tchirikov, Michael; Steetskamp, Joscha; Hohmann, Manfred; Koelbl, Heinz

    2010-09-01

    To introduce a novel method for the treatment of PPROM (preterm premature rupture of membranes) using continuous amnioinfusion via a subcutaneously implanted port system. After development and testing since 2001 in a fetal sheep model, the port system has been successfully implanted in two humans with PPROM. In the first case, the subcutaneous port system was implanted during the 23rd week of gestation in a 39-year-old 5th-gravida with PPROM since the 18th week of gestation; in the second case, the port system was implanted during the 24th week of gestation in a 27-year-old 3rd gravida with PPROM since the 21st week of gestation. After port implantation, 100ml/h saline solution was infused intermittently into the amniotic cavity. The whole course of treatment was supported by tocolysis. In the cases presented, gestation was terminated by cesarean section, in one case in the 29th week of gestation, and in the other case in the 30th week. The newborns showed no signs of lung hypoplasia and were successfully extubated on the 1st or 2nd day after delivery. Six months later the children did not exhibit any deviation from the normal development. Long-term amnioinfusion via a subcutaneously implanted port system could be used in humans with PPROM for prolongation of pregnancy and to avoid lung hypoplasia. Prospective randomized studies are ongoing. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.

  6. Cutaneous and inflammatory response to long-term percutaneous implants of sphere-templated porous/solid poly(HEMA) and silicone in Mice

    PubMed Central

    Fleckman, Philip; Usui, Marcia; Zhao, Ge; Underwood, Robert; Maginness, Max; Marshall, Andrew; Glaister, Christine; Ratner, Buddy; Olerud, John

    2012-01-01

    This study investigates mouse cutaneous responses to long-term percutaneously implanted rods surrounded by sphere-templated porous biomaterials engineered to mimic medical devices surrounded by a porous cuff. We hypothesized that keratinocytes would migrate through the pores and stop, permigrate, or marsupialize along the porous/solid interface. Porous/solid-core poly(2-hydroxyethyl methacrylate) [poly(HEMA)] and silicone rods were implanted in mice for 14 days, 1 month, 3 months, and 6 months. Implants with surrounding tissue were analyzed (immuno)histochemically by light microscopy. Poly(HEMA)/skin implants yielded better morphologic data than silicone implants. Keratinocytes at the poly(HEMA) interface migrated in two different directions. “Ventral” keratinocytes contiguous with the dermal-epidermal junction migrated into the outermost pores, forming an integrated collar surrounding the rods. ”Dorsal” keratinocytes appearing to emanate from the differentiated epithelial layer, extended upward along and into the exterior portion of the rod, forming an integrated sheath. Leukocytes persisted in poly(HEMA) and silicone pores for the duration of the study. Vascular and collagen networks within the poly(HEMA) pores matured as a function of time up to 3 months implantation. Nerves were not observed within the pores. Poly(HEMA) underwent morphological changes by 6 months of implantation. Marsupialization, foreign body encapsulation and infection were not observed in any implants. PMID:22359383

  7. Long-term results of uncemented alumina acetabular implants.

    PubMed

    Boehler, M; Knahr, K; Plenk, H; Walter, A; Salzer, M; Schreiber, V

    1994-01-01

    We report the clinical and tribological performance of 67 ceramic acetabular prostheses implanted between 1976 and 1979 without bone cement. They articulated with ceramic femoral heads mounted on mental femoral stems. After a mean elapsed period of 144 months, 59 sockets were radiographically stable but two showed early signs and six showed late signs of loosening. Four of the loose sockets have been revised. Histological analysis of the retrieved tissue showed a fibrous membrane around all the implants, with fibrocartilage in some. There was no bone ingrowth, and the fibrous membrane was up to 6 mm thick and infiltrated with lymphocytes, plasma cells, and macrophages. Intra- and extracellular birefringent wear particles were seen. Tribological analysis showed total wear rates in two retrieved alumina-on-alumina joints of 2.6 microns per year in a stable implant and 68 microns in a loose implant. Survival analysis showed a revision rate of 12.4% at 136 months.

  8. Long-term Conventionally Dosed Vancomycin Therapy In Patients With Orthopaedic Implant-related Infections Seems As Effective And Safe As Long-term Penicillin Or Clindamycin Therapy. A Retrospective Cohort Study Of 103 Patients.

    PubMed

    Aleman, Jacomien; Moojen, Dirk Jan F; van Ogtrop, Marc L; Poolman, Rudolf W; Franssen, Eric J F

    2018-01-01

    Objectives : Antimicrobial therapy is one of the cornerstones of orthopaedic implant-related infections (OIRI) treatment. Infections with Gram-positive bacteria are often treated with vancomycin, penicillin or clindamycin. A recent IDSA guideline suggests increasing the dose of vancomycin to increase the trough vancomycin target serum concentrations. This is deemed necessary because of an observed decrease in vancomycin susceptibility among Gram-positive bacteria. However, elevated vancomycin concentrations are correlated with the risk of nephrotoxicity, especially with prolonged therapy. Compared to most countries, rates of resistance against antibiotics among bacteria in the Netherlands are lower for currently available antibiotics, therefore lower target concentrations of vancomycin are probably efficacious for the treatment of infections. In this study we evaluated the efficacy and safety of long-term conventionally dosed vancomycin therapy, as an initial therapy for OIRI, and compared this with long-term penicillin and clindamycin therapy, as initial therapy, in patients with Gram-positive orthopaedic implant-related infections. Methods : A retrospective, observational study was conducted in 103 adult patients treated for OIRI, with vancomycin, penicillin or clindamycin for at least 10 days. The target trough serum concentration of vancomycin was 10-15 mg/l. Results : 74% of our patients were treated successfully with vancomycin, as initial therapy, (no reinfection within 1 year) versus 55% of our patients treated with either an antibiotic of the penicillin class (mostly flucloxacillin) or clindamycin (p=0.08), as initial therapy. For patients treated with vancomycin we observed a serum creatinine increase of 6 μmol/l, for patients treated with either an antibiotic of the penicillin class or clindamycin the serum creatinine increase was 4 μmol/l (p=0.395). Conclusions : In our population of patients with OIRI long-term treatment with conventionally dosed

  9. Long-term Conventionally Dosed Vancomycin Therapy In Patients With Orthopaedic Implant-related Infections Seems As Effective And Safe As Long-term Penicillin Or Clindamycin Therapy. A Retrospective Cohort Study Of 103 Patients

    PubMed Central

    Aleman, Jacomien; Moojen, Dirk Jan F.; van Ogtrop, Marc L.; Poolman, Rudolf W.; Franssen, Eric J.F.

    2018-01-01

    Objectives: Antimicrobial therapy is one of the cornerstones of orthopaedic implant-related infections (OIRI) treatment. Infections with Gram-positive bacteria are often treated with vancomycin, penicillin or clindamycin. A recent IDSA guideline suggests increasing the dose of vancomycin to increase the trough vancomycin target serum concentrations. This is deemed necessary because of an observed decrease in vancomycin susceptibility among Gram-positive bacteria. However, elevated vancomycin concentrations are correlated with the risk of nephrotoxicity, especially with prolonged therapy. Compared to most countries, rates of resistance against antibiotics among bacteria in the Netherlands are lower for currently available antibiotics, therefore lower target concentrations of vancomycin are probably efficacious for the treatment of infections. In this study we evaluated the efficacy and safety of long-term conventionally dosed vancomycin therapy, as an initial therapy for OIRI, and compared this with long-term penicillin and clindamycin therapy, as initial therapy, in patients with Gram-positive orthopaedic implant-related infections. Methods: A retrospective, observational study was conducted in 103 adult patients treated for OIRI, with vancomycin, penicillin or clindamycin for at least 10 days. The target trough serum concentration of vancomycin was 10-15 mg/l. Results: 74% of our patients were treated successfully with vancomycin, as initial therapy, (no reinfection within 1 year) versus 55% of our patients treated with either an antibiotic of the penicillin class (mostly flucloxacillin) or clindamycin (p=0.08), as initial therapy. For patients treated with vancomycin we observed a serum creatinine increase of 6 μmol/l, for patients treated with either an antibiotic of the penicillin class or clindamycin the serum creatinine increase was 4 μmol/l (p=0.395). Conclusions: In our population of patients with OIRI long-term treatment with conventionally dosed

  10. Bone marrow mononuclear cell implantation in myocardial laser channels in the ischemic heart disease surgery. Long-term results

    NASA Astrophysics Data System (ADS)

    Chernyavskiy, Alexander; Fomichev, Alexey; Minin, Stanislav; Nikitin, Nikita

    2017-10-01

    Background: The problem of incomplete myocardial revascularization for diffuse and distal lesions of the myocardium is still relevant. We assessed the clinical and instrumental long-term results of autologous bone marrow cell (BMC) implantation in laser channels in ischemic heart disease with diffuse and distal coronary disease. 35 coronary heart disease (CHD) patients with diffuse and distal coronary disease during coronary artery bypass grafting (CABG) underwent BMC implantation in laser channels. The control group consisted of 29 patients. All patients in this group underwent only CABG. Clinical and instrumental assessment of the method's effect was carried out at two weeks, six months, and six years after surgery. Indirect revascularization showed more significant decreasing of the functional class (FC) New York Heart Association (NYHA), myocardial perfusion and contractility improvement. Autologous BMC implantation in laser channels is an effective method of CHD surgical treatment if it is impossible to perform direct myocardial revascularization. The indirect revascularization effect is formed in the first six months after surgery and remains at the same level for six years.

  11. Trabecular micro-bypass stent implantation during small-incision cataract surgery for open-angle glaucoma or ocular hypertension: Long-term results.

    PubMed

    Neuhann, Tobias H

    2015-12-01

    To evaluate long-term safety and efficacy of iStent trabecular micro-bypass stent implantation during cataract surgery in patients with primary open-angle, pseudo-exfoliation glaucoma, ocular hypertension, or secondary or post-traumatic glaucoma. AaM Augenklinik am Marienplatz, Munich, Germany. Prospective, open-label, non-randomized study. Preoperative and postoperative evaluations included intra-ocular pressure (IOP), topical ocular hypotensive medication use, cup/disc ratio, corrected-distance visual acuity (CDVA), complications, and adverse events. A single trabecular micro-bypass stent was implanted through the same temporal, limbal incision used for cataract surgery via phacoemulsification in a consecutive series of 62 eyes of 43 patients. To date, a total of 41 eyes have been followed for 3 years postoperatively, whereas long-term postoperative follow-up on the remaining patients is ongoing. Mean preoperative IOP was 24.1 ± 6.9 mm Hg on a mean of 1.8 medications (±0.9). Analyses of eyes with no secondary surgical intervention showed mean IOP reduction to 14.8 ± 4.2 mm Hg at 12 months (n = 61), 14.5 ± 2.2 mm Hg at 24 months (n = 42), and 14.9 ± 2.3 mm Hg at 36 months (n = 39). Medications were eliminated in 74% of eyes at 36 months. Five eyes, 4 with previous glaucoma surgeries and 1 with pseudo-exfoliation syndrome, required additional glaucoma surgery after stent implantation. No intra-operative or postoperative complications typically seen with conventional glaucoma surgeries occurred after stent implantation. At 36 months, CDVA was 20/40 or better in 38 eyes (93%). Trabecular micro-bypass stent implantation during cataract surgery was safe and effective in patients with ocular hypertension or glaucoma as measured by a sustained reduction in IOP and medication use and an excellent safety profile through 3 years after surgery. Dr. Neuhann has no financial or proprietary interest in any material or method mentioned. Glaukos Corp. provided editorial

  12. Long-term actuarial survivorship analysis of an interspinous stabilization system

    PubMed Central

    Sénégas, Jacques; Pointillart, Vincent; Mangione, Paolo

    2007-01-01

    In 1986, an interspinous dynamic stabilization system (the prototype of the current Wallis implant) was designed to stiffen unstable operated degenerate lumbar segments with a hard interspinous blocker to limit extension and a tension band around the spinous processes to secure the implant and limit flexion. Restoring physiological mechanical conditions to the treated level(s) while preserving some intervertebral mobility was intended to treat low-back pain related to degenerative instability without increasing stress forces in the adjacent segments. The procedure was easily reversible. If low back pain persisted or recurred, the device was removed and stability was achieved using fusion. The intermediate-term results were promising, but the long-term safety and efficacy of this dynamic interspinous stabilization device has not been previously documented. We retrospectively reviewed the hospital files of all the patients (n = 241) who had this dynamic stabilization system implanted between 1987 and 1995, contacting as many as possible to determine the actuarial survivorship of the system. In this manner, 142 of the 241 patients (58.9%) were contacted by telephone. The endpoints used for the survivorship analysis were ‘any subsequent lumbar operation’ and ‘implant removal’. At 14 years follow-up, values of actuarial survivorship with 95% confidence interval were 75.9 ± 8.3 and 81.3 ± 6.8% for the endpoints ‘any subsequent lumbar operation’ and ‘implant removal’, respectively. There was no difference in survivorship of multiple-level implants with respect to single-level devices. Although the conclusions of the present study must be tempered by the 41% attrition rate, these findings support the long-term safety of this system, and possibly long-term protective action against adjacent-level degeneration by motion preservation. Outcomes at least equivalent to those of fusion were observed without the primary drawbacks of fusion. PMID:17426988

  13. Long-term improvements in oral communication skills and quality of peer relations in children with cochlear implants: parental testimony.

    PubMed

    Bat-Chava, Y; Martin, D; Imperatore, L

    2014-11-01

    Few research studies have examined longitudinal improvements in oral communication skills and quality of peer relationships of children with implants. Moreover, although the emerging literature suggests that improvement in social functioning follows improvement in oral communication, it is still unknown what factors enhance or impede the relations between these constructs. Based on parent interviews, the current study examined the long-term improvements in speech and oral language skills and relationships with hearing peers in 19 implanted children. Results demonstrate that on average, children continue to improve in oral communication skills and quality of peer relationships even years after implantation, especially those with initial poorer skills. While oral communication ability and quality of peer relationships are strongly associated at each time point, gains in these two variables are associated only for some of the children. Other factors, including self-confidence and peer acceptance, seem to moderate this relationship. Qualitative data are presented to illustrate these relations among variables and to assist in theory building. The results highlight the need for more specific examination of various developmental periods in combination with the progress of oral communication and peer relationships among children with implants. © 2013 John Wiley & Sons Ltd.

  14. Midterm to long-term safety and efficacy of self-expandable nitinol stent implantation for coarctation of aorta in adults.

    PubMed

    Haji Zeinali, Ali Mohammad; Sadeghian, Mohammad; Qureshi, Shakeel A; Ghazi, Payam

    2017-09-01

    Endovascular treatment of coarctation of aorta (CoA) by self-expandable Nitinol stents is one of the recognized treatment methods and may be an alternative to surgery or balloon-expandable stent implantation for CoA but there is little information about midterm to long term results of self-expandable stents. Sixty-two patients with CoA (40 men), with a mean age of 30.7 ± 11 years, (range 17-63 years) underwent stent implantation with Optimed self-expandable Nitinol stents between 2005 and 2014. Successful outcome was defined as peak systolic pressure gradient ≤20 mmHg after stent implantation. The patients were followed-up clinically and by echocardiography and in patients, in whom there was suspicion of recoarctation, CT angiography or recatheterization was performed. 65 stents were successfully implanted in all 62 patients. Peak systolic pressure gradient decreased from mean 62.4 ± 18 mmHg (range 35-100 mmHg) to mean 2.8 ± 5 mmHg (range 0-15 mmHg; P < 0.001). Stent displacement occurred in 3 patients during the procedure. These were managed successfully by an overlapping second stent. None of the patients had major complications such as aortic dissection, rupture, or vascular access problems. In follow up, only three patients had recoarctation, and two of these were managed successfully by balloon redilation or further stenting 16 and 18 months after the first procedure and one patient refused reintervention. There were two deaths, unrelated to the procedure, 12 and 78 months after the initial intervention. Follow-up of a mean of 45.5 ± 17 months (range 12-105 months) demonstrated no evidence of aneurysm formation or stent fracture. Self-expandable nitinol stents for the treatment of native and recurrent CoA is safe and has good efficacy with acceptable midterm to long-term outcome. © 2017 Wiley Periodicals, Inc.

  15. Biomechanical properties of polymer-infiltrated ceramic crowns on one-piece zirconia implants after long-term chewing simulation.

    PubMed

    Baumgart, Pia; Kirsten, Holger; Haak, Rainer; Olms, Constanze

    2018-05-23

    Implant and superstructure provide a complex system, which has to withstand oral conditions. Concerning the brittleness of many ceramics, fractures are a greatly feared issue. Therefore, polymer-infiltrated ceramic networks (PICNs) were developed. Because of its low Young's modulus and high elastic modulus, the PICN crown on a one-piece zirconia implant might absorb forces to prevent the system from fracturing in order to sustain oral forces. Recommendations for the material of superstructure on zirconia implants are lacking, and only one study investigates PICN crowns on these types of implants. Accordingly, this study aimed to examine PICN crowns on one-piece zirconia implants regarding bond strength and surface wear after long-term chewing simulation (CS). Twenty-five hybrid ceramic crowns (Vita Enamic, Vita Zahnfabrik) were produced using computer-aided design/computer-aided manufacturing (CAD/CAM) technology and adhesively bonded (RelyX™ Ultimate, 3M ESPE) to zirconia implants. Twenty of the specimens underwent simultaneous mechanical loading and thermocycling simulating a 5-year clinical situation (SD Mechatronik GmbH). Wear depth and wear volume, based on X-ray micro-computed tomography volume scans (Skyscan 1172-100-50, Bruker) before and after CS, were evaluated. All crowns were removed from the implants using a universal testing machine (Z010, Zwick GmbH&Co.KG). Subsequently, luting agent was light microscopically localized (Stemi 2000-C, Zeiss). With a scanning electron microscope (SEM, Phenom™ G2 pro, Phenom World), the area of abrasion was assessed. 1. After CS, none of the tested crowns were fractured or loosened. 2. The maximum vertical wear after CS was M = 0.31 ± 0.04 mm (mean ± standard deviation), and the surface wear was M = 0.74 ± 0.23 mm 3 . 3. The pull-off tests revealed a 1.8 times higher bond strength of the control group compared to the experimental group (t(23) = 8.69, p < 0.001). 4. Luting agent was

  16. Association Between Helicobacter Pylori Infection and Long-term Outcome in Patients with Drug-eluting Stent Implantation

    NASA Astrophysics Data System (ADS)

    Wang, Rui; Chen, Lei-Lei; Wang, De-Zhao; Chen, Bu-Xing

    2017-07-01

    To investigate the relationship between Helicobacter pylori (Hp) infection and the long-term outcome in acute coronary syndrome (ACS) patients with drug-eluting stent (DES) implantation and so as to explore the significance of Hp eradication therapy in preventing major adverse cardiac events (MACE) and upper gastrointestinal bleeding (UGIB). 539 ACS patients with DES implantation from January 1, 2010 to December 31, 2012 were analyzed. All the patients were divided into two groups according to the result of 13C urea breath test. 253 patients with Hp infection were put into group A (Hp+), and 286 cases without Hp infection were put into group B (Hp-). Demographic data was collected and all patients went through biochemical indicators and other routine blood examinations. We explored the correlations of Hp infection with MACE and UGIB after 3 to 5 years of follow-up using survival analysis. Survival analysis showed that Hp infection was a predictor of MACE and UGI. Sub-group analysis showed that patients with Hp eradication therapy had no relationship with MACE but had a lower rate of UGIB than those without Hp eradication therapy.

  17. Maintenance of class III trifurcated molars versus implant placement in regenerated extraction sockets: long-term results of 2 cases.

    PubMed

    Zafiropoulos, Gregory-George K; di Prisco, Manuela Occipite; Deli, Giorgio; Hoffmann, Oliver

    2011-03-01

    Studies to date have reached differing conclusions regarding the long-term prognosis of teeth with class III furcation involvement. Replacement of such teeth with implants could be an alternative. This report compares the treatment outcomes of 2 cases with similar disease progression: 1 treated by implant therapy and 1 maintained with nonsurgical periodontal treatment. Two patients with advanced chronic periodontitis and class III furcation involvement of all molars were treated. Case 1 received a conservative periodontal and antibiotic treatment, followed by 15 years of maintenance. In case 2, the molars were extracted and replaced with implants, and the implants were observed for 7 years. Clinical attachment level (CAL), probing attachment level (PAL), bleeding on probing, plaque index, and periodontal pathogens were recorded. Despite good compliance of case 1, periodontal pathogens were not eliminated and tissue destruction was not halted. The PAL outcomes of case 2 improved over time; mean PAL loss reached 0.35 mm/y in the first 3 years and then decreased to 0.01 mm/y. While CAL outcomes did not change in case 2, case 1 showed increased CAL loss after 8 years. Based on the limited findings of this case report, extraction of molars with class III furcation involvement and subsequent implant placement may render a better predictability of treatment outcomes than nonsurgical periodontal therapy in the cases of infection with periodontal pathogens.

  18. Long-term functional outcomes after artificial urinary sphincter implantation in women with stress urinary incontinence.

    PubMed

    Phé, Véronique; Benadiba, Steeve; Rouprêt, Morgan; Granger, Benjamin; Richard, François; Chartier-Kastler, Emmanuel

    2014-06-01

    To assess the long-term outcomes obtained after artificial urinary sphincter (AUS) implantation in women with stress urinary incontinence (SUI). Women with SUI caused by intrinsic sphincter deficiency who underwent an AUS placement between 1984 and 1992 were included. Explantation, revision and deactivation rates of the AUS were reported. Continence, defined as no pad use, was assessed at the end of the follow-up. Kaplan-Meier survival curves were generated to evaluate the survival rate of the device without explantation or revision. A total of 34 patients were included. The median (interquartile range [IQR]) age of the patients at surgery was 56.5 (50-64.7) years and the median (IQR) follow-up was 17 (12-19) years. Overall, 26 women (74%) still had their AUS in place at the end of the follow-up, while eight patients underwent an explantation of the device. The 10-, 15- and 20-year device survival rates without explantation were 80, 80 and 74%, respectively. The 10-, 15- and 20-year survival rates of the device without revision were 79, 65 and 40%, respectively. After 20 years of follow-up, 11 women still had successful outcomes (61%). The AUS provided satisfactory very long-term functional results among women with SUI caused by intrinsic sphincter deficiency. © 2013 The Authors. BJU International © 2013 BJU International.

  19. Stress urinary incontinence in female neurological patients: long-term functional outcomes after artificial urinary sphincter (AMS 800TM ) implantation.

    PubMed

    Phé, Véronique; Léon, Priscilla; Granger, Benjamin; Denys, Pierre; Bitker, Marc-Olivier; Mozer, Pierre; Chartier-Kastler, Emmanuel

    2017-03-01

    To report the long-term functional outcomes of artificial urinary sphincter (AUS) implantation in female adult neurological patients suffering from stress urinary incontinence (SUI) due to sphincter deficiency. Female patients with neurological disease suffering from SUI due to sphincter deficiency who underwent AUS (AMS 800 TM ) implantation between 1984 and 2011 were included. Continence rate defined as no need for pads and survival rates of the device without needing explantation or revision using Kaplan-Meier curves were reported. Overall, 26 patients, median age 49.2 years (IQR 28.5-59.7) were included. The median follow-up time was 7.5 years (IQR 3.9-23.8). At the end of follow-up period, 15 patients (57.7%) still had their primary AUS. The AUS was explanted in five women because of infection or erosion. Survival rates, without AUS explantation were 90%, 84%, 84%, and 74% at 5, 10, 15, 20 years, respectively. Survival rates without AUS revision were 75%, 51%, 51%, and 51% at 5, 10, 15, 20 years, respectively. 71.4% of patients with AUS were continent. When considering the 26 initial patients, including the patients in whom the AUS was explanted, the continence rate was 57.7%. For treating neurogenic sphincter deficiency in the long term, the AMS 800 TM can offer a satisfying rate of continence to female patients, with a tolerable rate of explantation and revision. Neurourol. Urodynam. 36:764-769, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  20. Long-term survival after ablation of the atrioventricular node and implantation of a permanent pacemaker in patients with atrial fibrillation.

    PubMed

    Ozcan, C; Jahangir, A; Friedman, P A; Patel, P J; Munger, T M; Rea, R F; Lloyd, M A; Packer, D L; Hodge, D O; Gersh, B J; Hammill, S C; Shen, W K

    2001-04-05

    In patients with atrial fibrillation that is refractory to drug therapy, radio-frequency ablation of the atrioventricular node and implantation of a permanent pacemaker are an alternative therapeutic approach. The effect of this procedure on long-term survival is unknown. We studied all patients who underwent ablation of the atrioventricular node and implantation of a permanent pacemaker at the Mayo Clinic between 1990 and 1998. Observed survival was compared with the survival rates in two control populations: age- and sex-matched members of the Minnesota population between 1970 and 1990 and consecutive patients with atrial fibrillation who received drug therapy in 1993. A total of 350 patients (mean [+/-SD] age, 68+/-11 years) were studied. During a mean of 36+/-26 months of follow-up, 78 patients died. The observed survival rate was significantly lower than the expected survival rate based on the general Minnesota population (P<0.001). Previous myocardial infarction (P<0.001), a history of congestive heart failure (P=0.02), and treatment with cardiac drugs after ablation (P=0.03) were independent predictors of death. Observed survival among patients without these three risk factors was similar to expected survival (P=0.43). None of the 26 patients with lone atrial fibrillation died during follow-up (37+/-27 months). The observed survival rate among patients who underwent ablation was similar to that among 229 controls with atrial fibrillation (mean age, 67+/-12 years) who received drug therapy (P=0.44). In the absence of underlying heart disease, survival among patients with atrial fibrillation after ablation of the atrioventricular node is similar to expected survival in the general population. Long-term survival is similar for patients with atrial fibrillation, whether they receive ablation or drug therapy. Control of the ventricular rate by ablation of the atrioventricular node and permanent pacing does not adversely affect long-term survival.

  1. Long-term clinical and prosthetic outcomes of soft liner and clip attachments for bar/implant overdentures: a randomised controlled clinical trial.

    PubMed

    ELsyad, M A; Shaheen, N H; Ashmawy, T M

    2017-06-01

    Long-term clinical and prosthetic outcomes of soft liner attachments for bar/implant overdentures were not sufficiently investigated. The aim of this trial was to evaluate clinical and prosthetic outcomes of resilient liner and clip attachments for bar/implant-retained mandibular overdenture after 7 years. Thirty edentulous male participants received two implants in the canine areas of the mandible. Three months later, implants were splinted with a resilient bar. Mandibular overdentures were connected to the bars with either clip (CR group, n = 15) or resilient liner (RR group, n = 15) attachments. Plaque index (PI), gingival index (GI), probing depth (PD), vertical bone loss (VBL), horizontal bone loss (HBLO) and prosthetic complications (PCs) were evaluated at denture delivery (T0), 6 (T 6m ), 12 (T1), 24 (T2), 36 (T3), 48 (T4), 60 (T5), 72 (T6) and 84 (T7) months after insertion. PI and GI increased significantly with time for CR and decreased significantly for RR (P < 0·001). PD increased at T1 (CR) and T6 m (RR) and then decreased thereafter (P < 0·05). VBL increased significantly with time in both groups (P < 0·005). HBLO increased at T2 (CR) and T1 (RR) and then decreased thereafter. CR recorded significant higher PI, GI, PD, VBLO and HBLO compared to RR at all observation times (P < 0·042). The survival rates were 96·6% and 100% for CR and RR after 7 years. The most common PCs for CR and RR were clip wears and separation of the resilient liner from the denture base, respectively. Within the limitations of this study, resilient liner attachments are recommended for bar/implant-retained mandibular overdentures than clip attachments in terms of peri-implant tissue health and prosthetic complications after 7 years. © 2017 John Wiley & Sons Ltd.

  2. Long-Term Speech and Language Outcomes in Prelingually Deaf Children, Adolescents and Young Adults Who Received Cochlear Implants in Childhood

    PubMed Central

    Ruffin, Chad V.; Kronenberger, William G.; Colson, Bethany G.; Henning, Shirley C.; Pisoni, David B.

    2013-01-01

    This study investigated long-term speech and language outcomes in 51 prelingually deaf children, adolescents, and young adults who received cochlear implants (CIs) prior to 7 years of age and used their implants for at least 7 years. Average speech perception scores were similar to those found in prior research with other samples of experienced CI users. Mean language test scores were lower than norm-referenced scores from nationally representative normal-hearing, typically-developing samples, although a majority of the CI users scored within one standard deviation of the normative mean or higher on the Peabody Picture Vocabulary Test, Fourth Edition (63%) and Clinical Evaluation of Language Fundamentals, Fourth Edition (69%). Speech perception scores were negatively associated with a meningitic etiology of hearing loss, older age at implantation, poorer pre-implant unaided pure tone average thresholds, lower family income, and the use of Total Communication. Users of CIs for 15 years or more were more likely to have these characteristics and were more likely to score lower on measures of speech perception compared to users of CIs for 14 years or less. The aggregation of these risk factors in the > 15 years of CI use subgroup accounts for their lower speech perception scores and may stem from more conservative CI candidacy criteria in use at the beginning of pediatric cochlear implantation. PMID:23988907

  3. Embedded Ultrathin Cluster Electrodes for Long-Term Recordings in Deep Brain Centers

    PubMed Central

    Thorbergsson, Palmi Thor; Ekstrand, Joakim; Friberg, Annika; Granmo, Marcus; Pettersson, Lina M. E.; Schouenborg, Jens

    2016-01-01

    Neural interfaces which allow long-term recordings in deep brain structures in awake freely moving animals have the potential of becoming highly valuable tools in neuroscience. However, the recording quality usually deteriorates over time, probably at least partly due to tissue reactions caused by injuries during implantation, and subsequently micro-forces due to a lack of mechanical compliance between the tissue and neural interface. To address this challenge, we developed a gelatin embedded neural interface comprising highly flexible electrodes and evaluated its long term recording properties. Bundles of ultrathin parylene C coated platinum electrodes (N = 29) were embedded in a hard gelatin based matrix shaped like a needle, and coated with Kollicoat™ to retard dissolution of gelatin during the implantation. The implantation parameters were established in an in vitro model of the brain (0.5% agarose). Following a craniotomy in the anesthetized rat, the gelatin embedded electrodes were stereotactically inserted to a pre-target position, and after gelatin dissolution the electrodes were further advanced and spread out in the area of the subthalamic nucleus (STN). The performance of the implanted electrodes was evaluated under anesthesia, during 8 weeks. Apart from an increase in the median-noise level during the first 4 weeks, the electrode impedance and signal-to-noise ratio of single-units remained stable throughout the experiment. Histological postmortem analysis confirmed implantation in the area of STN in most animals. In conclusion, by combining novel biocompatible implantation techniques and ultra-flexible electrodes, long-term neuronal recordings from deep brain structures with no significant deterioration of electrode function were achieved. PMID:27159159

  4. Long-term results of permanent metallic stent implantation in the treatment of benign upper urinary tract occlusion.

    PubMed

    Li, Xun; He, Zhaohui; Yuan, Jian; Zeng, Guohua; He, Yongzhong; Lei, Ming

    2007-08-01

    The management of complicated benign upper urinary tract occlusion is extremely challenging, especially in patients unable to undergo an open operative procedure. We report the long-term results of a permanent metallic stent for benign upper urinary tract occlusion. From October 1995 to December 1998, 13 patients (8 men and 5 women, with a mean age of 43 years) with benign upper tract occlusion have been treated by metallic stent implantation. All patients had a nephrostomy tube to relieve the obstruction and the average time of the nephrostomy tube stay was 27 months, ranging from 3 to 131 months. The average length of occlusion was 2.7 cm, ranging from 1 to 3.6 cm. Ultrasonography, urography, diuresis renography and urine culture were performed every 3 months after stent insertion. Ureteroscopy was done when needed. The mean follow-up was 92 months (12-132 months). Ureteral patency was achieved in six patients and assisted patency with a Double-J stent was achieved in three patients. In two patients the kidney had to be removed because of progressive malfunction and in two patients the metal stent had to be extracted with the Holmium: YAG laser, burning it down due to the uncontrollable pyonephrosis. In three patients the ipsilateral flank pain recurred. One of these patients experienced urine leakage due to the initial nephrostomy tract: a ureteroscopy revealed a complete hyperplastic urothelial response. Proximal stone formations were found in 2 patients and all were removed by percutaneous nephrolithotomy (PCNL). No stent migration or fragmentation was observed. The implantation of metal stent is a safe and effective treatment for benign upper urinary tract occlusion, and has satisfying long-term outcome in selected cases. A further investigation is needed for its impact on the urodynamics of upper urinary tract.

  5. Bio-inspired hybrid microelectrodes: a hybrid solution to improve long-term performance of chronic intracortical implants.

    PubMed

    De Faveri, Sara; Maggiolini, Emma; Miele, Ermanno; De Angelis, Francesco; Cesca, Fabrizia; Benfenati, Fabio; Fadiga, Luciano

    2014-01-01

    The use of implants that allow chronic electrical stimulation and recording in the brain of human patients is currently limited by a series of events that cause the deterioration over time of both the electrode surface and the surrounding tissue. The main reason of failure is the tissue inflammatory reaction that eventually causes neuronal loss and glial encapsulation, resulting in a progressive increase of the electrode-electrolyte impedance. Here, we describe a new method to create bio-inspired electrodes to mimic the mechanical properties and biological composition of the host tissue. This combination has a great potential to increase the implant lifetime by reducing tissue reaction and improving electrical coupling. Our method implies coating the electrode with reprogrammed neural or glial cells encapsulated within a hydrogel layer. We chose fibrin as a hydrogel and primary hippocampal neurons or astrocytes from rat brain as cellular layer. We demonstrate that fibrin coating is highly biocompatible, forms uniform coatings of controllable thickness, does not alter the electrochemical properties of the microelectrode and allows good quality recordings. Moreover, it reduces the amount of host reactive astrocytes - over time - compared to a bare wire and is fully reabsorbed by the surrounding tissue within 7 days after implantation, avoiding the common problem of hydrogels swelling. Both astrocytes and neurons could be successfully grown onto the electrode surface within the fibrin hydrogel without altering the electrochemical properties of the microelectrode. This bio-hybrid device has therefore a good potential to improve the electrical integration at the neuron-electrode interface and support the long-term success of neural prostheses.

  6. Long-Term Home Study on Nocturnal Hypoglycemic Alarms Using a New Fully Implantable Continuous Glucose Monitoring System in Type 1 Diabetes.

    PubMed

    Wang, Xiaolin; Ioacara, Sorin; DeHennis, Andrew

    2015-11-01

    This study analyzed the overall nocturnal performance during home use of a long-term subcutaneous implantable continuous glucose monitoring (CGM) sensor. In this study, 12 subjects with type 1 diabetes mellitus (T1DM) (mean±SD age, 37±8 years; mean±SD disease duration, 11±6 years) were implanted with an investigational continuous glucose sensor in the upper arm for up to 90 days. All subjects received full access to real-time glucose display and user programmable hypo- and hyperglycemic alarms. Subjects calibrated the sensors with a self-monitoring of blood glucose (SMBG) meter and continued to rely on their regular SMBG measurements for their diabetes management. Accuracy of the sensors during the home-use study was calculated using SMBG as the reference. The nocturnal sensor attenuation (NSA) concept was tested. Sensitivity and specificity of the nocturnal hypoglycemic alarm were calculated. Mean±SD glucose sensor life span was 87±7 days. The mean±SE absolute relative difference over the range of 40-400 mg/dL for the sensors in this home-use study was 12.3±0.7% using SMBG as the reference. The hypoglycemia alarms were set to be triggered when the glucose level went below 70 mg/dL. Percentage of nights with hypoglycemic alarms triggered for at least 10 min was 13.6%. Recovery into euglycemia within 30 min from the timestamp of the immediate confirmatory SMBG testing was obtained in 74% of all episodes (n=20). The implanted continuous glucose sensor showed a hypoglycemia detection sensitivity and specificity of 77% and 96%, respectively. The NSA-associated high negative rate of change of at least -4 mg/dL/min was not encountered during night use of the system. This home-use study of a fully implantable, long-term continuous glucose sensor shows excellent performance in nocturnal hypoglycemia detection in T1DM patients. The apparent lack of NSA affecting the implanted sensor and the high specificity of the hypoglycemic alarm expedite the recovery

  7. Verbal Processing Speed and Executive Functioning in Long-Term Cochlear Implant Users

    PubMed Central

    Pisoni, David B.; Kronenberger, William G.

    2015-01-01

    Purpose The purpose of this study was to report how verbal rehearsal speed (VRS), a form of covert speech used to maintain verbal information in working memory, and another verbal processing speed measure, perceptual encoding speed, are related to 3 domains of executive function (EF) at risk in cochlear implant (CI) users: verbal working memory, fluency-speed, and inhibition-concentration. Method EF, speech perception, and language outcome measures were obtained from 55 prelingually deaf, long-term CI users and matched controls with normal hearing (NH controls). Correlational analyses were used to assess relations between VRS (articulation rate), perceptual encoding speed (digit and color naming), and the outcomes in each sample. Results CI users displayed slower verbal processing speeds than NH controls. Verbal rehearsal speed was related to 2 EF domains in the NH sample but was unrelated to EF outcomes in CI users. Perceptual encoding speed was related to all EF domains in both groups. Conclusions Verbal rehearsal speed may be less influential for EF quality in CI users than for NH controls, whereas rapid automatized labeling skills and EF are closely related in both groups. CI users may develop processing strategies in EF tasks that differ from the covert speech strategies routinely employed by NH individuals. PMID:25320961

  8. Defibrillation threshold testing fails to show clinical benefit during long-term follow-up of patients undergoing cardiac resynchronization therapy defibrillator implantation.

    PubMed

    Michowitz, Yoav; Lellouche, Nicolas; Contractor, Tahmeed; Bourke, Tara; Wiener, Isaac; Buch, Eric; Boyle, Noel; Bersohn, Malcolm; Shivkumar, Kalyanam

    2011-05-01

    The utility of defibrillation threshold testing in patients undergoing implantable cardioverter-defibrillator (ICD) implantation is controversial. Higher defibrillation thresholds have been noted in patients undergoing implantation of cardiac resynchronization therapy defibrillators (CRT-D). Since the risks and potential benefits of testing may be higher in this population, we sought to assess the impact of defibrillation safety margin or vulnerability safety margin testing in CRT-D recipients. A total of 256 consecutive subjects who underwent CRT-D implantation between January 2003 and December 2007 were retrospectively reviewed. Subjects were divided into two groups based on whether (n= 204) or not (n= 52) safety margin testing was performed. Patient characteristics, tachyarrhythmia therapies, procedural results, and clinical outcomes were recorded. Baseline characteristics, including heart failure (HF) severity, were comparable between the groups. Four cases of HF exacerbation (2%), including one leading to one death, were recorded in the tested group immediately post-implantation. No complications were observed in the untested group. After a mean follow-up of 32 ± 20 months, the proportion of appropriate shocks in the two groups was similar (31 vs. 25%, P = 0.49). There were three cases of failed appropriate shocks in the tested group, despite adequate safety margins at implantation, whereas no failed shocks were noted in the untested group. Survival was similar in the two groups. Defibrillation efficacy testing during implant of CRT-D was associated with increased morbidity and did not predict the success of future device therapy or improve survival during long-term follow-up.

  9. Long-term evaluation of Astra Tech and Brånemark implants in patients treated with full-arch bridges. Results after 12-15 years.

    PubMed

    Ravald, Nils; Dahlgren, Simon; Teiwik, Anders; Gröndahl, Kerstin

    2013-10-01

    To study the long-term outcome of implant survival rate, soft and hard tissue conditions and prosthetic status in a group of individuals treated with either Astra Tech TiOblast or Brånemark turned implants supporting a full-arch bridge. Edentulous patients treated with either Astra Tech TiOblast surface or Brånemark turned implants were recalled for examination after 12-15 years. Out of initially 66 patients 46 were available for examination. Intra-oral radiographs were taken for bone level assessments. Clinical prosthetic conditions, number of surviving implants, implant stability, plaque scores, probing pocket depths, bleeding and pus after probing were recorded. Analyses of bone level changes during the total observation period were performed. Three patients in the Astra Tech group lost totally eight implants and five patients in the Brånemark group lost 10 implants during the total observation period. No statistically significant difference in implant loss or bone level change was found. Sixteen per cent of Astra Tech and 29% of Brånemark patients showed at least one implant with ≥2 mm bone loss after the first year in function. The corresponding prevalence on implant level was 6% and 5% respectively. No significant differences were found between the other examined variables. Two patients showed prosthetic complications of the supra construction in need of repair. Seven bridges had minor ceramic chippings. Treatment with Astra Tech TiOblast implants and Brånemark turned implants supporting full-arch bridges showed generally good clinical results with low numbers of implants with marginal bone loss indicative of peri-implantitis. No significant differences were found between the implant systems after 12-15 years in function. © 2012 John Wiley & Sons A/S.

  10. Feasibility of personalised remote long-term follow-up of people with cochlear implants: a randomised controlled trial.

    PubMed

    Cullington, Helen; Kitterick, Padraig; Weal, Mark; Margol-Gromada, Magdalena

    2018-04-20

    Substantial resources are required to provide lifelong postoperative care to people with cochlear implants. Most patients visit the clinic annually. We introduced a person-centred remote follow-up pathway, giving patients telemedicine tools to use at home so they would only visit the centre when intervention was required. To assess the feasibility of comparing a remote care pathway with the standard pathway in adults using cochlear implants. Two-arm randomised controlled trial. Randomisation used a minimisation approach, controlling for potential confounding factors. Participant blinding was not possible, but baseline measures occurred before allocation. University of Southampton Auditory Implant Service: provider of National Health Service care. 60 adults who had used cochlear implants for at least 6 months. Control group (n=30) followed usual care pathway.Remote care group (n=30) received care remotely for 6 months incorporating: home hearing in noise test, online support tool and self-adjustment of device (only 10 had compatible equipment). Primary: change in patient activation; measured using the Patient Activation Measure.Secondary: change in hearing and quality of life; qualitative feedback from patients and clinicians. One participant in the remote care group dropped out. The remote care group showed a greater increase in patient activation than the control group. Changes in hearing differed between the groups. The remote care group improved on the Triple Digit Test hearing test; the control group perceived their hearing was worse on the Speech, Spatial and Qualities of Hearing Scale questionnaire. Quality of life remained unchanged in both groups. Patients and clinicians were generally positive about remote care tools and wanted to continue. Adults with cochlear implants were willing to be randomised and complied with the protocol. Personalised remote care for long-term follow-up is feasible and acceptable, leading to more empowered patients. ISRCTN14644286

  11. Feasibility of personalised remote long-term follow-up of people with cochlear implants: a randomised controlled trial

    PubMed Central

    Kitterick, Padraig; Weal, Mark; Margol-Gromada, Magdalena

    2018-01-01

    remote care for long-term follow-up is feasible and acceptable, leading to more empowered patients. Trial registration number ISRCTN14644286. PMID:29678970

  12. [Role of totally implantable systems for long-term vascular access in the treatment of the neoplastic patient].

    PubMed

    Aldrighetti, L; Caterini, R; Ronzoni, M; Jannello, A; Ferla, G

    1995-05-01

    To assess retrospectively the effectiveness, the safety and the impact on the quality of life of the Subcutaneous Infusion Ports (SIPs) for prolonged venous access in the treatment of neoplastic patients. Retrospective analysis of a case series collected-during 30 months (April 1991-September 1993). General Surgery Division and Radiochemotherapy Service. 35 patients (23 male, 12 female), aged between 27-80 years, received 37 SIPs. 2 patients received 2 SIPs. 34 patients were affected by neoplasm; 1 patient had short gut syndrome secondary to massive small bowel resection. The SIP was implanted in all patients in the operating room with the Seldinger technique ("catheter over wire"). The suclavian vein, through an infraclavicular approach, was the only site of venous access. One SIP was implanted in the hepatic artery. All neoplastic patients received chemotherapy. The patient with short gut syndrome had parenteral nutrition. An external infusion device (CADD-1, CADD-plus, Pharmacia) was used in 13 patients for the continuous infusion of either 5-Fluoro-Uracil (1000 mg/m2/die for 5 days, every 28 days) or 5-Fluoro-Deoxy-Uridine (0.15-0.30 mg/kg/die for 14 days, every 28 days). SIP management required the port "flush" with normal saline solution with heparin (100 U/ml) at least every 40 days, using Huber needle. All patients were treated as outpatients. All intraoperative and long-term complications, recorded in the charts of the patients, were reviewed. The rate of intraoperative complications was assessed over 37 procedures. Long-term complications were assessed over 28 patients (7 patients were excluded for lack of follow up data). Incidence of complications was analyzed over patient days, considering the cumulative permanence time of the SIP in a single patient. We recorded 4 intraoperative complications (10.8%). None of them required to stop the procedure and to delay the implant of the SIP. During the follow-up period (range 1-18 months) we had 1 major

  13. Bio-inspired hybrid microelectrodes: a hybrid solution to improve long-term performance of chronic intracortical implants

    PubMed Central

    De Faveri, Sara; Maggiolini, Emma; Miele, Ermanno; De Angelis, Francesco; Cesca, Fabrizia; Benfenati, Fabio; Fadiga, Luciano

    2014-01-01

    The use of implants that allow chronic electrical stimulation and recording in the brain of human patients is currently limited by a series of events that cause the deterioration over time of both the electrode surface and the surrounding tissue. The main reason of failure is the tissue inflammatory reaction that eventually causes neuronal loss and glial encapsulation, resulting in a progressive increase of the electrode-electrolyte impedance. Here, we describe a new method to create bio-inspired electrodes to mimic the mechanical properties and biological composition of the host tissue. This combination has a great potential to increase the implant lifetime by reducing tissue reaction and improving electrical coupling. Our method implies coating the electrode with reprogrammed neural or glial cells encapsulated within a hydrogel layer. We chose fibrin as a hydrogel and primary hippocampal neurons or astrocytes from rat brain as cellular layer. We demonstrate that fibrin coating is highly biocompatible, forms uniform coatings of controllable thickness, does not alter the electrochemical properties of the microelectrode and allows good quality recordings. Moreover, it reduces the amount of host reactive astrocytes – over time – compared to a bare wire and is fully reabsorbed by the surrounding tissue within 7 days after implantation, avoiding the common problem of hydrogels swelling. Both astrocytes and neurons could be successfully grown onto the electrode surface within the fibrin hydrogel without altering the electrochemical properties of the microelectrode. This bio-hybrid device has therefore a good potential to improve the electrical integration at the neuron-electrode interface and support the long-term success of neural prostheses. PMID:24782757

  14. Long-term in vivo degradation behavior and near-implant distribution of resorbed elements for magnesium alloys WZ21 and ZX50.

    PubMed

    Amerstorfer, F; Fischerauer, S F; Fischer, L; Eichler, J; Draxler, J; Zitek, A; Meischel, M; Martinelli, E; Kraus, T; Hann, S; Stanzl-Tschegg, S E; Uggowitzer, P J; Löffler, J F; Weinberg, A M; Prohaska, T

    2016-09-15

    We report on the long-term effects of degrading magnesium implants on bone tissue in a growing rat skeleton using continuous in vivo micro-Computed Tomography, histological staining and Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS). Two different magnesium alloys-one rapidly degrading (ZX50) and one slowly degrading (WZ21)-were used to evaluate the bone response and distribution of released Mg and Y ions in the femur of male Sprague-Dawley rats. Regardless of whether the alloy degrades rapidly or slowly, we found that bone recovers restitutio ad integrum after complete degradation of the magnesium implant. The degradation of the Mg alloys generates a significant increase in Mg concentration in the cortical bone near the remaining implant parts, but the Mg accumulation disappears after the implant degrades completely. The degradation of the Y-containing alloy WZ21 leads to Y enrichment in adjacent bone tissues and in newly formed bone inside the medullary space. Locally high Y concentrations suggest migration not only of Y ions but also of Y-containing intermetallic particles. However, after the full degradation of the implant the Y-enrichment disappears almost completely. Hydrogen gas formation and ion release during implant degradation did not harm bone regeneration in our samples. Magnesium is generally considered to be one of the most attractive base materials for biodegradable implants, and many magnesium alloys have been optimized to adjust implant degradation. Delayed degradation, however, generates prolonged presence in the organism with the risk of foreign body reactions. While most studies so far have only ranged from several weeks up to 12months, the present study provides data for complete implant degradation and bone regeneration until 24months, for two magnesium alloys (ZX50, WZ21) with different degradation characteristics. μCT monitoring, histological staining and LA-ICP-MS illustrate the distribution of the elements in the

  15. Increasing levels of estradiol are deleterious to embryonic implantation because they directly affect the embryo.

    PubMed

    Valbuena, D; Martin, J; de Pablo, J L; Remohí, J; Pellicer, A; Simón, C

    2001-11-01

    To investigate whether the deleterious effect of E(2) on embryonic implantation is due to a direct effect on the endometrium, on the embryo, or both. Prospective, controlled in vitro study. Tertiary infertility center. Fertile patients in the luteal phase with histologically normal endometrium who were attending the infertility clinic as oocyte donors (n = 14). E(2) dose-response (0, 10(-8), 10(-7), 10(-6), 10(-5), and 10(-4) M) and time course (day 2 vs. day 5) experiments were performed in an in vitro embryo adhesion assay composed of human polarized endometrial epithelial cells obtained from fertile patients and mouse embryos. Blastocyst formation rate and embryo adhesion rate. Monolayers of polarized endometrial epithelial cells expressed ERalpha at the mRNA level. The E(2) dose response of blastocysts with polarized endometrial epithelial cells (n = 235) demonstrated a progressive reduction in embryonic adhesion that was statistically significant at 10(-6) M. When polarized endometrial epithelial cells were treated alone with increasing doses of E(2) for 3 days and E(2) was then removed and blastocysts added (n = 410), embryonic adhesion was not significantly reduced, except at 10(-4) M. When 2-day mouse embryos (n = 609) were treated with increasing E(2) concentrations until day 5, the rate of blastocyst formation significantly decreased at a concentration >or= 10(-6) M, and embryonic adhesion decreased when blastocysts (n = 400) were obtained at a concentration >or= 10(-7) M. Time course experiments of embryos cultured for 2 days with polarized endometrial epithelial cells (n = 426) showed that the adhesion rate was higher at E(2) levels of 10(-7), 10(-6) and 10(-5) M compared with embryos cultured for 5 days (n = 495). High E(2) levels are deleterious to embryo adhesion in vitro, mainly because they have a direct toxic effect on the embryo that may occur at the cleavage stage.

  16. Long-term outcomes of uveitic glaucoma treated with Ahmed valve implant in a series of Chinese patients.

    PubMed

    Bao, Ning; Jiang, Zheng-Xuan; Coh, Paul; Tao, Li-Ming

    2018-01-01

    To report long-term outcomes of secondary glaucoma due to uveitis treated with Ahmed glaucoma valve (AGV) implantation in a series of Chinese patients. The retrospective study included 67 eyes from 56 patients with uveitic glaucoma who underwent AGV implantation. Success of the treatment was defined as patients achieving intraocular pressure (IOP) levels between 6 and 21 mm Hg with or without additional anti-glaucoma medications and/or a minimum of 20% reduction from baseline IOP. The main outcome measurements included IOP, the number of glaucoma medications at 1, 3, 6, 12, 24, 36, 48 and 60mo after surgery, surgical complications, final best-corrected vision acuity (BCVA), visual field (VF) and retinal nerve fiber layer (RNFL). The mean follow-up was 53.3±8.5 (range 48 to 60)mo. The cumulative probability of success rate was 98.5%, 95.5%, 89.6%, 83.6%, 76.1%, 70.1%, 65.7% and 61.2% at 1, 3, 6, 12, 24, 36, 48 and 60mo, respectively. IOP was reduced from a baseline of 30.8±6.8 to 9.9±4.1, 10.1±4.2, 10.9±3.7, 12.9±4.6, 13.8±3.9, 13.2±4.6, 12.3±3.5 and 13.1±3.7 mm Hg at 1, 3, 6, 12, 24, 36, 48 and 60mo, respectively ( P <0.01). The number of postoperative glaucoma medications was significantly decreased compared with baseline at all time points during the study period ( P <0.05). There was no significant difference between preoperative and postoperative BCVA. Remarkable surgical complications were not found after surgery. The VF and RNFL of the patients were stable after the surgery. AGV implantation is safe and effect in terms of reducing IOP, decreasing the number of glaucoma medications, and preserving vision for patients with uveitic glaucoma.

  17. Corrosion of stainless steel sternal wire after long-term implantation.

    PubMed

    Tomizawa, Yasuko; Hanawa, Takao; Kuroda, Daisuke; Nishida, Hiroshi; Endo, Masahiro

    2006-01-01

    A variety of metallic components have been used in medical devices where lifelong durability and physical strength are demanded. To investigate the in vivo changes of implanted metallic medical devices in humans, stainless steel sternal wires removed from patients were evaluated. Stainless steel (316L) sternal wires removed from four patients after 10, 13, 22, and 30 years of implantation were evaluated using scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS). Macroscopically, the removed specimens maintained their metallic luster and color. Under SEM, small holes were observed sporadically at 10 years and they tended to connect in the drawing direction. The longer the implanted duration, the more numerous and deeper were the crevices observed. By EDS, sulfur, phosphorus, and calcium were identified in all areas at 10 years, in addition to the component elements of stainless steel, comprising iron, chromium, nickel, and manganese. Corrosion products observed at 30 years were identified as calcium phosphate. In conclusion, stainless steel sternal wires develop corroded pores that grow larger and deeper with time after implantation; however, the pores remain shallow even after decades of implantation and they may not be a cause of mechanical failure. An amount of metal ions equivalent to the corroded volume must have been released into the human body, but the effect of these metal ions on the body is not apparent.

  18. Long-term Blood Pressure Measurement in Freely Moving Mice Using Telemetry.

    PubMed

    Alam, Mohammad Afaque; Parks, Cory; Mancarella, Salvatore

    2016-05-17

    During the development of new vasoactive agents, arterial blood pressure monitoring is crucial for evaluating the efficacy of the new proposed drugs. Indeed, research focusing on the discovery of new potential therapeutic targets using genetically altered mice requires a reliable, long-term assessment of the systemic arterial pressure variation. Currently, the gold standard for obtaining long-term measurements of blood pressure in ambulatory mice uses implantable radio-transmitters, which require artery cannulation. This technique eliminates the need for tethering, restraining, or anesthetizing the animals which introduce stress and artifacts during data sampling. However, arterial blood pressure monitoring in mice via catheterization can be rather challenging due to the small size of the arteries. Here we present a step-by-step guide to illustrate the crucial key passages for a successful subcutaneous implantation of radio-transmitters and carotid artery cannulation in mice. We also include examples of long-term blood pressure activity taken from freely moving mice after a period of post-surgery recovery. Following this procedure will allow reliable direct blood pressure recordings from multiple animals simultaneously.

  19. Long-term clinical study and multiscale analysis of in vivo biodegradation mechanism of Mg alloy

    PubMed Central

    Lee, Jee-Wook; Han, Hyung-Seop; Han, Kyeong-Jin; Park, Jimin; Jeon, Hojeong; Ok, Myoung-Ryul; Seok, Hyun-Kwang; Ahn, Jae-Pyoung; Lee, Kyung Eun; Lee, Dong-Ho; Yang, Seok-Jo; Cho, Sung-Youn; Cha, Pil-Ryung; Kwon, Hoon; Nam, Tae-Hyun; Han, Jee Hye Lo; Rho, Hyoung-Jin; Lee, Kang-Sik; Kim, Yu-Chan; Mantovani, Diego

    2016-01-01

    There has been a tremendous amount of research in the past decade to optimize the mechanical properties and degradation behavior of the biodegradable Mg alloy for orthopedic implant. Despite the feasibility of degrading implant, the lack of fundamental understanding about biocompatibility and underlying bone formation mechanism is currently limiting the use in clinical applications. Herein, we report the result of long-term clinical study and systematic investigation of bone formation mechanism of the biodegradable Mg-5wt%Ca-1wt%Zn alloy implant through simultaneous observation of changes in element composition and crystallinity within degrading interface at hierarchical levels. Controlled degradation of Mg-5wt%Ca-1wt%Zn alloy results in the formation of biomimicking calcification matrix at the degrading interface to initiate the bone formation process. This process facilitates early bone healing and allows the complete replacement of biodegradable Mg implant by the new bone within 1 y of implantation, as demonstrated in 53 cases of successful long-term clinical study. PMID:26729859

  20. Latissimus dorsi myocutaneous reconstruction: a study of long-term outcomes in a district general hospital.

    PubMed

    Kallaway, C; Humphreys, A; Laurence, N; Sutton, R

    2016-11-01

    INTRODUCTION The aim of this study was to evaluate the long-term outcome and durability of both autologous and implant-assisted latissimus dorsi reconstruction in a district general hospital over a 10-year follow-up period. METHODS A prospective cohort study was carried out using a detailed database of all latissimus dorsi flap reconstructions performed by a single consultant surgeon between 2003 and 2013 at the Royal United Hospital, Bath. The long-term outcome following reconstruction was assessed by analysing all episodes of 'reconstruction-specific' operations required from 6 months after the initial surgery. RESULTS The study included 110 patients with latissimus dorsi flap reconstructions, 21 autologous and 95 implant-assisted. Radiotherapy was given to 27 patients with reconstructed flaps. Mean follow-up was 69 months. Further reconstruction-specific surgery was needed in 27 (23%) cases, with 5 of these being post-radiotherapy flaps. Implant-related surgery was the most common reason for further surgery. Complications of the implant itself made up 52% of these cases, chronic sepsis being the most common. The rate of symptomatic capsular contracture requiring further surgery was 4.2%. Of these, one of four patients had undergone radiotherapy. DISCUSSION In our institution, latissimus dorsi reconstruction is durable and safe over the long term, with limited need for further substantial intervention to maintain a good outcome from the initial reconstruction. Autologous flaps were less likely to require further surgery over the long term compared with implant-based reconstructions. The low rate of symptomatic capsular contracture may be due to the protective mechanism provided by the extended harvest flap used.

  1. Analysis of metallic traces from the biodegradation of endomedullary AZ31 alloy temporary implants in rat organs after long implantation times.

    PubMed

    Bodelón, O G; Iglesias, C; Garrido, J; Clemente, C; Garcia-Alonso, M C; Escudero, M L

    2015-08-04

    AZ31 alloy has been tested as a biodegradable material in the form of endomedullary implants in female Wistar rat femurs. In order to evaluate the accumulation of potentially toxic elements from the biodegradation of the implant, magnesium (Mg), aluminium (Al), zinc (Zn), manganese (Mn) and fluorine (F) levels have been measured in different organs such as kidneys, liver, lungs, spleen and brain. Several factors that may influence accumulation have been taken into account: how long the implant has been in place, whether or not the bone is fractured, and the presence of an MgF2 protective coating on the implant. The main conclusions and the clinical relevance of the study have been that AZ31 endomedullary implants have a degradation rate of about 60% after 13 months, which is fully compatible with fracture consolidation. Neither bone fracture nor an MgF2 coating seems to influence the accumulation of trace elements in the studied organs. Aluminium is the only alloying element in this study that requires special attention. The increase in Al recovered from the sampled organs represents 3.95% of the amount contained in the AZ31 implant. Al accumulates in a statistically significant way in all the organs except the brain. All of this suggests that in long-term tests AZ31 may be a suitable material for osteosynthesis.

  2. Trehalose limits BSA aggregation in spray-dried formulations at high temperatures: implications in preparing polymer implants for long-term protein delivery.

    PubMed

    Rajagopal, Karthikan; Wood, Joseph; Tran, Benjamin; Patapoff, Thomas W; Nivaggioli, Thierry

    2013-08-01

    Polymer implants are promising systems for sustained release applications but their utility for protein delivery has been hindered because of concerns over drug stability at elevated temperatures required for processing. Using bovine serum albumin (BSA) as a model, we have assessed whether proteins can be formulated for processing at elevated temperatures. Specifically, the effect of trehalose and histidine-HCl buffer on BSA stability in a spray-dried formulation has been investigated at temperatures ranging from 80°C to 110°C. When both the sugar and buffer are present, aggregation is suppressed even when exposed to 100°C, the extrusion temperature of poly(lactide-co-glycolide) (PLGA), a bioresorbable polymer. Estimation of aggregation rate constants (k) indicate that though both trehalose and histidine-HCl buffer contribute to BSA stability, the effect because of trehalose alone is more pronounced. BSA-loaded PLGA implants were prepared using hot-melt extrusion process and in vitro release was conducted in phosphate buffered saline at 37°C. Comparison of drug released from implants prepared using four different formulations confirmed that maximal release was achieved from the formulation in which BSA was least aggregated. These studies demonstrate that when trehalose and histidine-HCl buffer are included in spray-dried formulations, BSA stability is maintained both during processing at 100°C and long-term residence within implants. Copyright © 2013 Wiley Periodicals, Inc.

  3. Long-term Outcomes of Ahmed Glaucoma Valve Implantation in Refractory Glaucoma at Farabi Eye Hospital, Tehran, Iran

    PubMed Central

    Zarei, Reza; Amini, Heidar; Daneshvar, Ramin; Nabi, Fahimeh Naderi; Moghimi, Sasan; Fakhraee, Ghasem; Eslami, Yadollah; Mohammadi, Masoud; Amini, Nima

    2016-01-01

    Purpose: To describe long-term outcomes and complications of Ahmed glaucoma valve (AGV) implantation in subjects with refractory glaucoma at Farabi Eye Hospital, Tehran, Iran. Materials and Methods: This retrospective cohort study evaluated patient records of all subjects with refractory glaucoma who had undergone AGV implantation up to January 2013. The main outcome measure was the surgical success rate. Complete success was defined as intraocular pressure (IOP) <22 mmHg, without anti-glaucoma medications or additional surgery. Qualified success was IOP <22 mmHg regardless of number of anti-glaucoma medications. In all cases, loss of vision (no light perception) was considered an independent indicator of failure. Data were also collected on intraoperative and postoperative complications. Results: Twenty-eight eyes were included in the study. With a mean follow-up of 48.2 ± 31.7 months (median: 40.50 months; range: 3–124 months), the IOP decreased from a mean preoperative value of 30.8 ± 5.6 mmHg to 20.0 ± 6.4 mmHg at last visit. The number of medications decreased from 3.7 ± 0.4 preoperatively to 2.5 ± 1.1 postoperatively. Cumulative qualified success was achieved in 69% of eyes. Mean time to failure according to qualified success criteria was 92.3 ± 9.4 months. Postoperative complications were recorded in 16 (57.1%) eyes. The most common complication was focal endothelial corneal decompensation at the site of tube-cornea touch. Conclusion: AGV implantation with adjunctive topical anti-glaucoma drops controlled IOP in approximately 70% of eyes with refractory glaucoma with a median of 40.5 months of follow-up. However, complication rates were higher. PMID:26957848

  4. Long-term Outcomes of Ahmed Glaucoma Valve Implantation in Refractory Glaucoma at Farabi Eye Hospital, Tehran, Iran.

    PubMed

    Zarei, Reza; Amini, Heidar; Daneshvar, Ramin; Nabi, Fahimeh Naderi; Moghimi, Sasan; Fakhraee, Ghasem; Eslami, Yadollah; Mohammadi, Masoud; Amini, Nima

    2016-01-01

    To describe long-term outcomes and complications of Ahmed glaucoma valve (AGV) implantation in subjects with refractory glaucoma at Farabi Eye Hospital, Tehran, Iran. This retrospective cohort study evaluated patient records of all subjects with refractory glaucoma who had undergone AGV implantation up to January 2013. The main outcome measure was the surgical success rate. Complete success was defined as intraocular pressure (IOP) <22 mmHg, without anti-glaucoma medications or additional surgery. Qualified success was IOP <22 mmHg regardless of number of anti-glaucoma medications. In all cases, loss of vision (no light perception) was considered an independent indicator of failure. Data were also collected on intraoperative and postoperative complications. Twenty-eight eyes were included in the study. With a mean follow-up of 48.2 ± 31.7 months (median: 40.50 months; range: 3-124 months), the IOP decreased from a mean preoperative value of 30.8 ± 5.6 mmHg to 20.0 ± 6.4 mmHg at last visit. The number of medications decreased from 3.7 ± 0.4 preoperatively to 2.5 ± 1.1 postoperatively. Cumulative qualified success was achieved in 69% of eyes. Mean time to failure according to qualified success criteria was 92.3 ± 9.4 months. Postoperative complications were recorded in 16 (57.1%) eyes. The most common complication was focal endothelial corneal decompensation at the site of tube-cornea touch. AGV implantation with adjunctive topical anti-glaucoma drops controlled IOP in approximately 70% of eyes with refractory glaucoma with a median of 40.5 months of follow-up. However, complication rates were higher.

  5. Long-term results of total knee arthroplasty for valgus knees: soft-tissue release technique and implant selection.

    PubMed

    Rajgopal, Ashok; Dahiya, Vivek; Vasdev, Attique; Kochhar, Hemanshu; Tyagi, Vipin

    2011-04-01

    To report long-term results of total knee arthroplasty (TKA) for valgus knees. 34 women and 19 men aged 39 to 84 (mean, 74) years with valgus knees underwent primary TKA by a senior surgeon. Of the 78 knees, 43, 29, and 6 had type-I, type-II, and type-III valgus deformities, respectively. A preliminary lateral soft-tissue release was performed, and the tibia and femur were prepared. The tight lateral structures were released using the pie-crusting technique. In 92% of the knees, cruciate-retaining implants were used. In knees with severe deformity and medial collateral ligament insufficiency, the posterior cruciate ligament was sacrificed and constrained implants were used. The Hospital for Special Surgery (HSS) knee score was assessed, as were tibiofemoral alignment, range of motion, stability, and evidence of loosening or osteolysis. Patients were followed up for 8 to 14 (mean, 10) years. All knees had a good patellar position and were clinically stable in both mediolateral and anteroposterior planes. No radiolucency was noted. The mean HSS knee score improved from 48 to 91 (p<0.001). The mean tibiofemoral alignment improved from valgus 20 to 5 degrees (p<0.001). The mean range of motion improved from 65 to 110 degrees (p<0.001). One patient developed a deep infection at year 4, and 2 had periprosthetic fractures at years 6 and 8. Adequate lateral soft-tissue release is the key to successful TKAs in valgus knees. The choice of implant depends on the severity of the valgus deformity and the extent of soft-tissue release needed to obtain a stable, balanced flexion and extension gap, in order to achieve minimal constraint with maximum stability.

  6. Surgical Tooth Implants, Combat and Field.

    DTIC Science & Technology

    1985-11-15

    project in the development of dental implantology must not be overlooked. The early stages of this project clearly defined that rigid fixation of an...a long-term implant study of a serrated ceramic dental implant designed for fresh extraction sites. The baboon study was successfully completed last...materials. A series of graded dental implants have been produce’ to provide an interference fit in any fresh extraction site. The long-term implant

  7. Long-Term Morphological and Microarchitectural Stability of Tissue-Engineered, Patient-Specific Auricles In Vivo

    PubMed Central

    Cohen, Benjamin Peter; Hooper, Rachel C.; Puetzer, Jennifer L.; Nordberg, Rachel; Asanbe, Ope; Hernandez, Karina A.; Spector, Jason A.

    2016-01-01

    Current techniques for autologous auricular reconstruction produce substandard ear morphologies with high levels of donor-site morbidity, whereas alloplastic implants demonstrate poor biocompatibility. Tissue engineering, in combination with noninvasive digital photogrammetry and computer-assisted design/computer-aided manufacturing technology, offers an alternative method of auricular reconstruction. Using this method, patient-specific ears composed of collagen scaffolds and auricular chondrocytes have generated auricular cartilage with great fidelity following 3 months of subcutaneous implantation, however, this short time frame may not portend long-term tissue stability. We hypothesized that constructs developed using this technique would undergo continued auricular cartilage maturation without degradation during long-term (6 month) implantation. Full-sized, juvenile human ear constructs were injection molded from high-density collagen hydrogels encapsulating juvenile bovine auricular chondrocytes and implanted subcutaneously on the backs of nude rats for 6 months. Upon explantation, constructs retained overall patient morphology and displayed no evidence of tissue necrosis. Limited contraction occurred in vivo, however, no significant change in size was observed beyond 1 month. Constructs at 6 months showed distinct auricular cartilage microstructure, featuring a self-assembled perichondrial layer, a proteoglycan-rich bulk, and rounded cellular lacunae. Verhoeff's staining also revealed a developing elastin network comparable to native tissue. Biochemical measurements for DNA, glycosaminoglycan, and hydroxyproline content and mechanical properties of aggregate modulus and hydraulic permeability showed engineered tissue to be similar to native cartilage at 6 months. Patient-specific auricular constructs demonstrated long-term stability and increased cartilage tissue development during extended implantation, and offer a potential tissue-engineered solution for

  8. Dissociation between perceptual processing and priming in long-term lorazepam users.

    PubMed

    Giersch, Anne; Vidailhet, Pierre

    2006-12-01

    Acute effects of lorazepam on visual information processing, perceptual priming and explicit memory are well established. However, visual processing and perceptual priming have rarely been explored in long-term lorazepam users. By exploring these functions it was possible to test the hypothesis that difficulty in processing visual information may lead to deficiencies in perceptual priming. Using a simple blind procedure, we tested explicit memory, perceptual priming and visual perception in 15 long-term lorazepam users and 15 control subjects individually matched according to sex, age and education level. Explicit memory, perceptual priming, and the identification of fragmented pictures were found to be preserved in long-term lorazepam users, contrary to what is usually observed after an acute drug intake. The processing of visual contour, on the other hand, was still significantly impaired. These results suggest that the effects observed on low-level visual perception are independent of the acute deleterious effects of lorazepam on perceptual priming. A comparison of perceptual priming in subjects with low- vs. high-level identification of new fragmented pictures further suggests that the ability to identify fragmented pictures has no influence on priming. Despite the fact that they were treated with relatively low doses and far from peak plasma concentration, it is noteworthy that in long-term users memory was preserved.

  9. An Analysis of Patient Perceptions and Expectations to Dental Implants: Is There a Significant Effect on Long-Term Satisfaction Levels?

    PubMed Central

    2017-01-01

    Here we present an analysis of patient perceptions and expectations to dental implant placement and their prosthetic reconstruction, to then consider whether they have an effect on long-term satisfaction levels. A Post-Treatment Completion Questionnaire was designed to analyse whether patient satisfaction is influenced by age and/or gender; has an effect on patient-reported self-confidence levels; contributes to increased levels of oral hygiene; provides further insight into the average pain levels during and after the surgical intervention; or influences further acceptance of dental implant surgery. And then whether relationships exist between any of these factors. 182 consecutive patients completed the survey: 68 males and 114 females (age mean 64.68 years ± 11.23 SD); the average number of months since treatment completion was 37.4 (males) and 62.6 (females). There is a significant relationship between comfort rating and “how well informed” the patient was (p = 0.015). A significantly positive relationship exists between “considering dental implants in the future” and “overall experience” (p = 0.001). A significantly positive relationship exists between “overall satisfaction with appearance” and “satisfaction with comfort” (p = 0.011). A significant relationship exists between “overall satisfaction with appearance,” “satisfaction with comfort,” and “overall satisfaction with experience” (p = 0.001). The results amplify the need to transmit logical, truthful information to patients when dental implant treatment is being considered. The “fully informed” patient will have realistic expectations that lead to high degrees of satisfaction. PMID:28928771

  10. Long-term effects of interference on short-term memory performance in the rat.

    PubMed

    Missaire, Mégane; Fraize, Nicolas; Joseph, Mickaël Antoine; Hamieh, Al Mahdy; Parmentier, Régis; Marighetto, Aline; Salin, Paul Antoine; Malleret, Gaël

    2017-01-01

    A distinction has always been made between long-term and short-term memory (also now called working memory, WM). The obvious difference between these two kinds of memory concerns the duration of information storage: information is supposedly transiently stored in WM while it is considered durably consolidated into long-term memory. It is well acknowledged that the content of WM is erased and reset after a short time, to prevent irrelevant information from proactively interfering with newly stored information. In the present study, we used typical WM radial maze tasks to question the brief lifespan of spatial WM content in rodents. Groups of rats were submitted to one of two different WM tasks in a radial maze: a WM task involving the repetitive presentation of a same pair of arms expected to induce a high level of proactive interference (PI) (HIWM task), or a task using a different pair in each trial expected to induce a low level of PI (LIWM task). Performance was effectively lower in the HIWM group than in LIWM in the final trial of each training session, indicative of a "within-session/short-term" PI effect. However, we also observed a different "between-session/long-term" PI effect between the two groups: while performance of LIWM trained rats remained stable over days, the performance of HIWM rats dropped after 10 days of training, and this impairment was visible from the very first trial of the day, hence not attributable to within-session PI. We also showed that a 24 hour-gap across training sessions known to allow consolidation processes to unfold, was a necessary and sufficient condition for the long-term PI effect to occur. These findings suggest that in the HIWM task, WM content was not entirely reset between training sessions and that, in specific conditions, WM content can outlast its purpose by being stored more permanently, generating a long-term deleterious effect of PI. The alternative explanation is that WM content could be transferred and stored

  11. Ring and peg electrodes for minimally-Invasive and long-term sub-scalp EEG recordings.

    PubMed

    Benovitski, Y B; Lai, A; McGowan, C C; Burns, O; Maxim, V; Nayagam, D A X; Millard, R; Rathbone, G D; le Chevoir, M A; Williams, R A; Grayden, D B; May, C N; Murphy, M; D'Souza, W J; Cook, M J; Williams, C E

    2017-09-01

    Minimally-invasive approaches are needed for long-term reliable Electroencephalography (EEG) recordings to assist with epilepsy diagnosis, investigation and more naturalistic monitoring. This study compared three methods for long-term implantation of sub-scalp EEG electrodes. Three types of electrodes (disk, ring, and peg) were fabricated from biocompatible materials and implanted under the scalp in five ambulatory ewes for 3months. Disk electrodes were inserted into sub-pericranial pockets. Ring electrodes were tunneled under the scalp. Peg electrodes were inserted into the skull, close to the dura. EEG was continuously monitored wirelessly. High resolution CT imaging, histopathology, and impedance measurements were used to assess the status of the electrodes at the end of the study. EEG amplitude was larger in the peg compared with the disk and ring electrodes (p<0.05). Similarly, chewing artifacts were lower in the peg electrodes (p<0.05). Electrode impedance increased after long-term implantation particularly for those within the bone (p<0.01). Micro-CT scans indicated that all electrodes stayed within the sub-scalp layers. All pegs remained within the burr holes as implanted with no evidence of extrusion. Eight of 10 disks partially eroded into the bone by 1.0mm from the surface of the skull. The ring arrays remained within the sub-scalp layers close to implantation site. Histology revealed that the electrodes were encapsulated in a thin fibrous tissue adjacent to the pericranium. Overlying this was a loose connective layer and scalp. Erosion into the bone occurred under the rim of the sub-pericranial disk electrodes. The results indicate that the peg electrodes provided high quality EEG, mechanical stability, and lower chewing artifact. Whereas, ring electrode arrays tunneled under the scalp enable minimal surgical techniques to be used for implantation and removal. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Long-term erythropoietin gene expression from transduced cells in bioisolator devices.

    PubMed

    Yanay, Ofer; Barry, Simon C; Flint, Lisa Y; Brzezinski, Margaret; Barton, Randall W; Osborne, William R A

    2003-11-20

    Recombinant erythropoietin (EPO) is widely administered for long-term treatment of anemia associated with renal failure and other chronic diseases. The ability to deliver EPO by gene therapy would have clinical and economic benefit. We compared autologous and allogeneic transduced primary vascular smooth muscle cells for their ability to provide sustained EPO gene expression when encapsulated in TheraCyte devices implanted subcutaneously (SQ) or intraperitoneally (IP) in rats. Cells were transduced with retrovirus vector LrEpSN encoding rat EPO cDNA. Rats that received either autologous or allogeneic transduced cells showed elevated hematocrits (HCTs) ranging from 50 to 79% that were sustained for more than 12 months. The HCT of control rats remained at baseline (45.8%). Rats that received second SQ implants of either autologous or allogeneic cells showed elevations in hematocrit that were sustained for up to 12 months, suggesting the absence of immunological responses to transduced cells or implant material. All experimental groups had statistically significant elevated HCT (p < 0.001) when compared with controls. Both SQ and IP implantation were equally effective in delivering EPO long term. There were no significant differences in white blood cell (WBC) or platelet (PLT) values between treated and control animals. Implantation of TheraCyte devices was well tolerated and histological evaluation of the devices up to 12 months after surgery revealed a high degree of vascularization and no evidence of host immune response. TheraCyte devices offer a simple and safe gene delivery system that provides sustained therapeutic gene expression, permit removal and implantation of new devices, and do not require immunosuppression of the host.

  13. The clinical implications of poly implant prothèse breast implants: an overview.

    PubMed

    Wazir, Umar; Kasem, Abdul; Mokbel, Kefah

    2015-01-01

    Mammary implants marketed by Poly Implant Prothèse (PIP) were found to contain industrial grade silicone and this caused heightened anxiety and extensive publicity regarding their safety in humans. These implants were used in a large number of patients worldwide for augmentation or breast reconstruction. We reviewed articles identified by searches of Medline, PubMed, Embase, and Google Scholar databases up to May 2014 using the terms: "PIP", "Poly Implant Prothèse", "breast implants" and "augmentation mammoplasty" "siloxanes" or "silicone". In addition the websites of regulating bodies in Europe, USA, and Australia were searched for reports related to PIP mammary implants. PIP mammary implants are more likely to rupture than other implants and can cause adverse effects in the short to the medium term related to the symptoms of rupture such as pain, lumps in the breast and axilla and anxiety. Based on peer-reviewed published studies we have calculated an overall rupture rate of 14.5% (383/2,635) for PIP implants. However, there is no evidence that PIP implant rupture causes long-term adverse health effects in humans so far. Silicone lymphadenopathy represents a foreign body reaction and should be treated conservatively. The long-term adverse effects usually arise from inappropriate extensive surgery, such as axillary lymph node dissection or extensive resection of breast tissue due to silicone leakage.

  14. The Clinical Implications of Poly Implant Prothèse Breast Implants: An Overview

    PubMed Central

    Wazir, Umar; Kasem, Abdul

    2015-01-01

    Mammary implants marketed by Poly Implant Prothèse (PIP) were found to contain industrial grade silicone and this caused heightened anxiety and extensive publicity regarding their safety in humans. These implants were used in a large number of patients worldwide for augmentation or breast reconstruction. We reviewed articles identified by searches of Medline, PubMed, Embase, and Google Scholar databases up to May 2014 using the terms: "PIP", "Poly Implant Prothèse", "breast implants" and "augmentation mammoplasty" "siloxanes" or "silicone". In addition the websites of regulating bodies in Europe, USA, and Australia were searched for reports related to PIP mammary implants. PIP mammary implants are more likely to rupture than other implants and can cause adverse effects in the short to the medium term related to the symptoms of rupture such as pain, lumps in the breast and axilla and anxiety. Based on peer-reviewed published studies we have calculated an overall rupture rate of 14.5% (383/2,635) for PIP implants. However, there is no evidence that PIP implant rupture causes long-term adverse health effects in humans so far. Silicone lymphadenopathy represents a foreign body reaction and should be treated conservatively. The long-term adverse effects usually arise from inappropriate extensive surgery, such as axillary lymph node dissection or extensive resection of breast tissue due to silicone leakage. PMID:25606483

  15. Early Life Fructose Exposure and Its Implications for Long-Term Cardiometabolic Health in Offspring.

    PubMed

    Zheng, Jia; Feng, Qianyun; Zhang, Qian; Wang, Tong; Xiao, Xinhua

    2016-11-01

    It has become increasingly clear that maternal nutrition can strongly influence the susceptibility of adult offspring to cardiometabolic disease. For decades, it has been thought that excessive intake of fructose, such as sugar-sweetened beverages and foods, has been linked to increased risk of obesity, type 2 diabetes, and cardiovascular disease in various populations. These deleterious effects of excess fructose consumption in adults are well researched, but limited data are available on the long-term effects of high fructose exposure during gestation, lactation, and infancy. This review aims to examine the evidence linking early life fructose exposure during critical periods of development and its implications for long-term cardiometabolic health in offspring.

  16. Long-term Outcomes Following Artificial Urinary Sphincter Placement: An Analysis of 1082 Cases at Mayo Clinic.

    PubMed

    Linder, Brian J; Rivera, Marcelino E; Ziegelmann, Matthew J; Elliott, Daniel S

    2015-09-01

    To evaluate long-term device outcomes following primary artificial urinary sphincter (AUS) implantation. We identified 1802 male patients with stress urinary incontinence that underwent AUS placement from 1983 to 2011. Of these, 1082 (60%) were involving primary implantations and comprise the study cohort. Multiple clinical and surgical variables were evaluated for potential association with treatment failure, defined as any secondary surgery. Patient follow-up was obtained through office examination, operative report, and written or telephone correspondence. Patients undergoing AUS implantation had a median age of 71 years (interquartile range 66-76) and median follow-up of 4.1 years (interquartile range 0.8-7.7). Overall, 338 of 1082 patients (31.2%) underwent secondary surgery, including 89 for device infection and/or erosion, 131 for device malfunction, 89 for urethral atrophy, and 29 for pump malposition or tubing complications. No patient-related risk factors were independently associated with an increased risk of secondary surgery on multivariable analysis. Secondary surgery-free survival was 90% at 1 year, 74% at 5 years, 57% at 10 years, and 41% at 15 years. Primary AUS implantation is associated with acceptable long-term outcomes. Recognition of long-term success is important for preoperative patient counseling. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. A comparative analysis of the effectiveness of active versus passive atrial lead fixation in Chinese patients with cardiac implantable electrical devices: a long term, retrospective, observational, single-center study.

    PubMed

    Hao, Yinglu; Li, Yanping; Liao, Derong; Yang, Ling; Liu, Fangyan

    2017-03-01

    Data comparing active atrial lead fixation with passive atrial lead fixation in Chinese patients with cardiovascular implantable electronic devices (CIEDs) for atrial pacing is limited. Our study evaluated the effectiveness of active fixation versus passive fixation of atrial leads by observing the lead performance parameters. This retrospective, long-term, single-center study included a cohort of Chinese patients who underwent CIED implantation at the Department of Cardiology of People's Hospital of Yuxi City, China, from 1 March 2010 to 1 March 2015. Efficacy was determined by comparing implantation time, threshold values, incidence of lead dislocation/failure, and lead-related complications between the two groups. Of the 1217 patients, active and passive atrial lead fixation were performed in 530 (mean age, 69.37 ± 11.44 years) and 497 (mean age, 68.33 ± 10.96 years). The active fixation group reported significantly lower mean atrial implantation times (P = .0001) and threshold values (P = .044) compared with the passive atrial lead fixation group. In addition, threshold values in the active atrial lead fixation group were stable throughout the observation period. No instances of myocardial perforation, cardiac tamponade, implantation failure, or electrode dislocation/re-fixation were reported in the active atrial lead fixation group. A favorable decrease in patient comfort parameters such as bed rest time (P = .027) and duration of hospital stay (P = .038) were also observed in the active lead fixation group. Active atrial lead fixation demonstrated greater stability, steady long-term thresholds and minimal lead-related complications compared to passive lead fixation in Chinese patients with CIEDs.

  18. The long term effect of an iris-supported lens on the endothelium.

    PubMed

    Galin, M A; Dotson, R S; Obstbaum, S A; Tuberville, A W

    1982-01-01

    A retrospective study of 104 eyes that had iris-supported Sputnik intraocular lenses implanted and no surgery in the fellow eye and a separate series of 30 implanted eyes whose second eyes underwent surgery but did not receive implants disclosed that endothelial cell densities in the eyes with implants decreased immediately after surgery and then continued to decrease at the same rate as those of the control eyes. There was no sudden decrease in the endothelial cell counts during follow-up periods ranging from three to seven years. The main cause of large cell losses immediately after surgery, and possibly long-term corneal decompensation, was surgical manipulation rather than the presence of this style of intraocular lens.

  19. Long-term reproducibility of Edinger-Westphal stimulated accommodation in rhesus monkeys.

    PubMed

    He, Lin; Wendt, Mark; Glasser, Adrian

    2013-08-01

    If longitudinal studies of accommodation or accommodation restoration procedures are undertaken in rhesus monkeys, the methods used to induce and measure accommodation must remain reproducible over the study period. Stimulation of the Edinger-Westphal (EW) nucleus in anesthetized rhesus monkeys is a valuable method to understand various aspects of accommodation. A prior study showed reproducibility of EW-stimulated accommodation over 14 months after chronic electrode implantation. However, reproducibility over a period longer than this has not been investigated and therefore remains unknown. To address this, accommodation stimulation experiments in four eyes of two rhesus monkeys (13.7 and 13.8 years old) were evaluated over a period of 68 months. Carbachol iontophoresis stimulated accommodation was first measured with a Hartinger coincidence refractometer (HCR) two weeks before electrode implantation to determine maximum accommodative amplitudes. EW stimulus-response curves were initially measured with the HCR one month after electrode implantation and then repeated at least six times for each eye in the following 60 months. At 64 months, carbachol iontophoresis induced accommodation was measured again. At 68 months, EW stimulus-response curves were measured with an HCR and photorefraction every week over four consecutive weeks to evaluate the short-term reproducibility over one month. In the four eyes studied, long-term EW-stimulated accommodation decreased by 7.00 D, 3.33 D, 4.63 D, and 2.03 D, whereas carbachol stimulated accommodation increased by 0.18 D-0.49 D over the same time period. The short-term reproducibility of maximum EW-stimulated accommodation (standard deviations) over a period of four weeks at 68 months after electrode implantation was 0.48 D, 0.79 D, 0.55 D and 0.39 D in the four eyes. Since the long-term decrease in EW-stimulated accommodation is not matched by similar decreases in carbachol iontophoresis stimulated accommodation, the decline

  20. Textile for heart valve prostheses: fabric long-term durability testing.

    PubMed

    Heim, Frederic; Durand, Bernard; Chakfe, Nabil

    2010-01-01

    The rapid developments and success in percutaneous vascular surgery over the last two decades with the now common stent grafts implantation, make the noninvasive surgery technique today attractive even for heart valve replacement. Less traumatic for the patient and also less time consuming, percutaneous heart valve replacement is however at its beginning and restricted to end of life patients. The noninvasive procedure expects from the heart valve prosthesis material to be resistant and adapted to folding requirements of the implantation process (catheter). Polyester fabric could be a suited material for heart valve implanted percutaneously. Highly flexible and resistant, polyester fabric proved to be well adapted to the dynamic behavior of a valve and polyester (Dacron) is also widely used for vascular grafts implantation and shows good biocompatibility and durability. However, today there's no data available on long-term durability of fabric used as heart valve material. The purpose of this work is to study the long term behavior of a microdenier polyester fabric construction under combined in vitro flexure and tension fatigue stress. In the novel in vitro testing technique presented, a fabric specimen was subjected to combined flexural and tensile fatigue generated by fluid flow under physiological pressure conditions. The results obtained show how flexural properties change with fatigue time, which reflects directly on the suitability of a fabric in such devices. It was also observed that these fabric structural changes directly influence the in vitro behavior of the textile heart valve prosthesis. (c) 2009 Wiley Periodicals, Inc.

  1. A Novel Scheme and Evaluations on a Long-Term and Continuous Biosensor Platform Integrated with a Dental Implant Fixture and Its Prosthetic Abutment

    PubMed Central

    Li, Yu-Jung; Lu, Chih-Cheng

    2015-01-01

    A miniature intra-oral dental implant system including a built-in biosensor device is proposed in this article. The dental implant system, or platform, is replaced over maxilla and allows relatively non-invasive procedures for a novel biosensing scheme for human blood analysis. Due to placement of the implant fixture, periodontal ligaments and the pulp structure, which are regarded as the main origin of pain, are thus removed, and long-term, continuous blood analysis and management through maxillary bone marrow becomes achievable through the dental implant platform. The new pathway of biological sensing is for the first time presented to realize an accurate and painless approach without injections. The dental implant system mainly consists of an implant fixture and a prosthetic abutment, a biosensor module, a bluetooth 4.0 wireless module and a dc button cell battery. The electrochemical biosensor possesses three electrodes, including working, reference and counter ones, which are arranged to pass through the titanium implant fixture below the biosensor module. The electrodes are exposed to the blood pool inside the maxillary bone marrow and perform oxidation/reduction reactions with the coating of biosensing enzyme. To prove the proposed platform, the immobilization process of glucose oxidase (GOD) enzyme and in vitro detections of glucose levels are successfully carried out, and proven sensitivity, linearity and repeatability of the glucose biosensor system are obtained. Moreover, a preliminary canine animal model adopting the new pathway shows significant consistency with the traditional method through dermal pricks for blood sugar detection. Despite the prospective results, further challenges in engineering implementation and clinical practices are addressed and discussed. In brief, the novel biosensing pathway and intra-oral biosensor platform may increasingly reveal their promising value and feasibilities in current bio-medical analysis, diagnosis, drug

  2. A Novel Scheme and Evaluations on a Long-Term and Continuous Biosensor Platform Integrated with a Dental Implant Fixture and Its Prosthetic Abutment.

    PubMed

    Li, Yu-Jung; Lu, Chih-Cheng

    2015-09-25

    A miniature intra-oral dental implant system including a built-in biosensor device is proposed in this article. The dental implant system, or platform, is replaced over maxilla and allows relatively non-invasive procedures for a novel biosensing scheme for human blood analysis. Due to placement of the implant fixture, periodontal ligaments and the pulp structure, which are regarded as the main origin of pain, are thus removed, and long-term, continuous blood analysis and management through maxillary bone marrow becomes achievable through the dental implant platform. The new pathway of biological sensing is for the first time presented to realize an accurate and painless approach without injections. The dental implant system mainly consists of an implant fixture and a prosthetic abutment, a biosensor module, a bluetooth 4.0 wireless module and a dc button cell battery. The electrochemical biosensor possesses three electrodes, including working, reference and counter ones, which are arranged to pass through the titanium implant fixture below the biosensor module. The electrodes are exposed to the blood pool inside the maxillary bone marrow and perform oxidation/reduction reactions with the coating of biosensing enzyme. To prove the proposed platform, the immobilization process of glucose oxidase (GOD) enzyme and in vitro detections of glucose levels are successfully carried out, and proven sensitivity, linearity and repeatability of the glucose biosensor system are obtained. Moreover, a preliminary canine animal model adopting the new pathway shows significant consistency with the traditional method through dermal pricks for blood sugar detection. Despite the prospective results, further challenges in engineering implementation and clinical practices are addressed and discussed. In brief, the novel biosensing pathway and intra-oral biosensor platform may increasingly reveal their promising value and feasibilities in current bio-medical analysis, diagnosis, drug

  3. Long-term stability of peri-implant tissues after bone or soft tissue augmentation. Effect of zirconia or titanium abutments on peri-implant soft tissues. Summary and consensus statements. The 4th EAO Consensus Conference 2015.

    PubMed

    Sicilia, Alberto; Quirynen, Marc; Fontolliet, Alain; Francisco, Helena; Friedman, Anton; Linkevicius, Tomas; Lutz, Rainer; Meijer, Henny J; Rompen, Eric; Rotundo, Roberto; Schwarz, Frank; Simion, Massimo; Teughels, Wim; Wennerberg, Ann; Zuhr, Otto

    2015-09-01

    Several surgical techniques and prosthetic devices have been developed in the last decades, aiming to improve aesthetic, hygienic and functional outcomes that may affect the peri-implant tissues, such as procedures of bone and soft tissue augmentation and the use of custom-made abutments of titanium and zirconium. Three systematic reviews, based on randomized clinical trials and prospective studies covering the above reported topics were analysed, and the detected evidence was exposed to interactive experts' discussion during the group's and general assembly's meetings of the 4th EAO Consensus Conference. The results are reported using the following abbreviations: S-T: short-term evidence, M-T: medium-term evidence; L-T: long-term evidence; LE: limited evidence. Soft tissue augmentation procedures may be indicated for the increase of soft tissue thickness and keratinized tissue, the reduction of interproximal peri-implant bone loss, and the coverage of shallow peri-implant soft tissue recessions (S-T, LE), L-T is lacking. Guided bone regeneration approaches (GBR) showed efficacy when used for ridge reconstruction after the complete healing of the soft tissues (S-T & L-T), and the stability of the augmented bone may play a role in the maintenance of the soft tissue position and dimensions (LE). No significant differences were observed between titanium and zirconia abutments when evaluating probing pocket depth, bleeding on probing, marginal bone levels and mucosal recessions. Zirconia abutments were associated with more biological complications but demonstrated superiority in terms of achieving natural soft tissue colour (S-T). © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Long-term Follow-up with AlloDerm in Breast Reconstruction.

    PubMed

    Baxter, Richard A

    2013-05-01

    Little is known about the long-term fate of acellular dermal matrices in breast implant surgery. A 12-year follow-up case with tissue analysis of AlloDerm in revision breast reconstruction reveals retention of graft volume and integration with an organized collagen structure, minimal capsule formation, and little or no indication of inflammation.

  5. Long-term effects of interference on short-term memory performance in the rat

    PubMed Central

    Missaire, Mégane; Fraize, Nicolas; Joseph, Mickaël Antoine; Hamieh, Al Mahdy; Parmentier, Régis; Marighetto, Aline; Salin, Paul Antoine; Malleret, Gaël

    2017-01-01

    A distinction has always been made between long-term and short-term memory (also now called working memory, WM). The obvious difference between these two kinds of memory concerns the duration of information storage: information is supposedly transiently stored in WM while it is considered durably consolidated into long-term memory. It is well acknowledged that the content of WM is erased and reset after a short time, to prevent irrelevant information from proactively interfering with newly stored information. In the present study, we used typical WM radial maze tasks to question the brief lifespan of spatial WM content in rodents. Groups of rats were submitted to one of two different WM tasks in a radial maze: a WM task involving the repetitive presentation of a same pair of arms expected to induce a high level of proactive interference (PI) (HIWM task), or a task using a different pair in each trial expected to induce a low level of PI (LIWM task). Performance was effectively lower in the HIWM group than in LIWM in the final trial of each training session, indicative of a “within-session/short-term” PI effect. However, we also observed a different “between-session/long-term” PI effect between the two groups: while performance of LIWM trained rats remained stable over days, the performance of HIWM rats dropped after 10 days of training, and this impairment was visible from the very first trial of the day, hence not attributable to within-session PI. We also showed that a 24 hour-gap across training sessions known to allow consolidation processes to unfold, was a necessary and sufficient condition for the long-term PI effect to occur. These findings suggest that in the HIWM task, WM content was not entirely reset between training sessions and that, in specific conditions, WM content can outlast its purpose by being stored more permanently, generating a long-term deleterious effect of PI. The alternative explanation is that WM content could be transferred and

  6. Biological Strategies for Improved Osseointegration and Osteoinduction of Porous Metal Orthopedic Implants

    PubMed Central

    Riester, Scott M.; Bonin, Carolina A.; Kremers, Hilal Maradit; Dudakovic, Amel; Kakar, Sanjeev; Cohen, Robert C.; Westendorf, Jennifer J.

    2015-01-01

    The biological interface between an orthopedic implant and the surrounding host tissue may have a dramatic effect upon clinical outcome. Desired effects include bony ingrowth (osseointegration), stimulation of osteogenesis (osteoinduction), increased vascularization, and improved mechanical stability. Implant loosening, fibrous encapsulation, corrosion, infection, and inflammation, as well as physical mismatch may have deleterious clinical effects. This is particularly true of implants used in the reconstruction of load-bearing synovial joints such as the knee, hip, and the shoulder. The surfaces of orthopedic implants have evolved from solid-smooth to roughened-coarse and most recently, to porous in an effort to create a three-dimensional architecture for bone apposition and osseointegration. Total joint surgeries are increasingly performed in younger individuals with a longer life expectancy, and therefore, the postimplantation lifespan of devices must increase commensurately. This review discusses advancements in biomaterials science and cell-based therapies that may further improve orthopedic success rates. We focus on material and biological properties of orthopedic implants fabricated from porous metal and highlight some relevant developments in stem-cell research. We posit that the ideal primary and revision orthopedic load-bearing metal implants are highly porous and may be chemically modified to induce stem cell growth and osteogenic differentiation, while minimizing inflammation and infection. We conclude that integration of new biological, chemical, and mechanical methods is likely to yield more effective strategies to control and modify the implant–bone interface and thereby improve long-term clinical outcomes. PMID:25348836

  7. Long-term Follow-up with AlloDerm in Breast Reconstruction

    PubMed Central

    2013-01-01

    Summary: Little is known about the long-term fate of acellular dermal matrices in breast implant surgery. A 12-year follow-up case with tissue analysis of AlloDerm in revision breast reconstruction reveals retention of graft volume and integration with an organized collagen structure, minimal capsule formation, and little or no indication of inflammation. PMID:25289211

  8. Long-term follow-up of stentless prosthesis.

    PubMed

    Sansone, Fabrizio; Dato, Guglielmo Mario Actis; Zingarelli, Edoardo; Ferrero, Emanuele; Prot, Sara; Ceresa, Fabrizio; Patanè, Francesco; Casabona, Riccardo

    2014-05-01

    Stentless prostheses have an interesting hemodynamic performance when compared to stented prostheses and are recommended in cases of small aortic annulus. From January 1996 to January 2004, 138 patients suffering from aortic disease, underwent aortic valve replacement. • Group A: 93 patients underwent stentless aortic valve implantation [stentless Biocor (Biocor Industria e Pesguisa Ltda, Belo Horizonte, Brazil) and stentless Sorin (Sorin Group, Saluggia, Italy)]. • Group B: 45 patients underwent stented aortic valve implantation (stented Biocor). Patients were assessed by clinical evaluation and echocardiography after a mean follow up of 124.5 ± 58.2 months. There was a significant difference in terms of time of extracorporeal circulation and aortic cross clamp. The actuarial survival at 4, 8, 12, and 15 years is 77%, 50%, 21%, and 18%, respectively. Freedom from reoperation at 4, 8, 12, and 14 years was 92%, 83%, 73%, and 63%, respectively. Freedom from all events, death, and reoperation at 4, 8, 12, and 14 years was 70%, 39%, 13%, and 8%, respectively. There is no statistical difference among the two groups in terms of actuarial survival, freedom from reoperation, and freedom from re-hospitalization for prosthesis-related causes. There was a significantly higher incidence of pacemaker implantation in Group A and the causes are not known. The rate of freedom from reoperation is high in both groups for the patients who remained alive. There was no statistical difference about prosthesis dysfunction between the two groups. The higher incidence of death in Group A cannot be explained by causes related to the prosthesis because there is no difference in terms of causes of death. Rates of reoperation did not differ between the two groups. The results obtained with stentless prostheses are encouraging even in long-term follow-up. Copyright © 2013 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  9. Percutaneous implanted paddle lead for spinal cord stimulation: technical considerations and long-term follow-up.

    PubMed

    Kinfe, Thomas M; Schu, Stefan; Quack, Florian J; Wille, Christian; Vesper, Jan

    2012-07-01

    Spinal cord stimulation (SCS) is an established method for treatment of chronic pain. Cylindrical-type leads can be implanted percutaneously. In contrast, paddle leads (lamitrode) require more invasive surgery (i.e., laminotomy or laminectomy) for placement into the epidural space, thereby offering several advantages over percutaneous leads (octrode), including less lead migration and better paresthesia coverage. The goal of this study was to prospectively demonstrate the safety and efficacy of a percutaneous paddle lead for SCS. This prospective trial enrolled 81 patients. The mean age was 57 years (range 27-82 years) with an almost equal sex distribution (male 47%, female 53%). Most patients (90%) had failed back surgery syndrome combined with lower extremity pain and lower back pain. A percutaneous paddle lead was implanted using a novel introduction system for percutaneous implantation. All implantations were performed under local anesthesia. Prior to the final implantation of the impulse generator, all patients underwent seven days of trial stimulation with pain assessment using a visual analog scale (VAS). The median follow-up was 12 months. The data showed favorable clinical outcomes for paresthesia coverage and pain reduction (median VAS 8.4 vs. 2.3), with a risk profile comparable with known percutaneous techniques. Compared with the published data (2-22%), the lead migration rate in this study was low (2.5%). No perioperative complications occurred. This new, minimally invasive percutaneous paddle lead is effective and safe, with a low migration rate. Placement can be done under local anesthesia, allowing an intraoperative assessment of the paresthesia coverage in terms of pain relief. This approach is less invasive and offers a faster and more comfortable procedure compared with laminotomy or laminectomy. © 2012 International Neuromodulation Society.

  10. Long-Term Primary Patency Rate After Nitinol Self-Expandable Stents Implantation in Long, Totally Occluded Femoropopliteal (TASC II C & D) Lesions.

    PubMed

    Elmahdy, Mahmoud Farouk; Buonamici, Piergiovanni; Trapani, Maurizio; Valenti, Renato; Migliorini, Angela; Parodi, Guido; Antoniucci, David

    2017-06-01

    Endovascular therapy for long femoropopliteal lesions using percutaneous transluminal balloon angioplasty or first-generation of peripheral stents has been associated with unacceptable one-year restenosis rates. However, with recent advances in equipment and techniques, a better primary patency rate is expected. This study was conducted to detect the long-term primary patency rate of nitinol self-expandable stents implanted in long, totally occluded femoropopliteal lesions TransAtlantic Inter-Society Census (TASC II type C & D), and determine the predictors of reocclusion or restenosis in the stented segments. The demographics, clinical, anatomical, and procedural data of 213 patients with 240 de novo totally occluded femoropopliteal (TASC II type C & D) lesions treated with nitinol self-expandable stents were retrospectively analysed. Of these limbs, 159 (66.2%) presented with intermittent claudication, while 81 (33.8%) presented with critical limb ischaemia. The mean-time of follow-up was 36±22.6 months, (range: 6.3-106.2 months). Outcomes evaluated were, primary patency rate and predictors of reocclusion or restenosis in the stented segments. The mean age of the patients was 70.9±9.3 years, with male gender 66.2%. Mean pre-procedural ABI was 0.45±0.53. One-hundred-and-seventy-five (73%) lesions were TASC II type C, while 65 (27%) were type D lesions. The mean length of the lesions was 17.9±11.3mm. Procedure related complications occurred in 10 (4.1%) limbs. There was no periprocedural mortality. Reocclusion and restenosis were detected during follow-up in 45 and 30 limbs respectively, and all were re-treated by endovascular approach. None of the patients required major amputation. Primary patency rates were 81.4±1.1%, 77.7±1.9% and 74.4±2.8% at 12, 24, and 36 months respectively. Male gender, severe calcification, and TASC II D lesion were independent predictors for reocclusion, while predictors of restenosis were DM, smoking and TASC II D lesions

  11. Use of GnRH agonist implants for long-term suppression of fertility in extensively managed heifers and cows.

    PubMed

    D'Occhio, Michael J; Fordyce, Geoffry; Whyte, Tim R; Jubb, Tristan F; Fitzpatrick, Lee A; Cooper, Neil J; Aspden, William J; Bolam, Matt J; Trigg, Timothy E

    2002-12-16

    The ability of gonadotrophin releasing hormone (GnRH) agonist implants to suppress ovarian activity and prevent pregnancies, long-term, was examined in heifers and cows maintained under extensive management. At three cattle stations, heifers (2-year-old) and older cows (3- to 16-year-old) were assigned to a control group that received no treatment, or were treated with high-dose (12 mg, Station A) or low-dose (8 mg, Station B and Station C) GnRH agonist implants. The respective numbers of control and GnRH agonist-treated animals (heifers + cows) at each station were: Station A, 20 and 99; Station B, 19 and 89; Station C, 20 and 76. Animals were maintained with 4% bulls and monitored for pregnancy at 2-monthly intervals for approximately 12 months. Pregnancy rates for control heifers and control cows ranged from 60-90% and 80-100%, respectively, depending on the study site. The respective number of animals (heifers + cows) treated with GnRH agonist that conceived, and days to first conception, were: Station A, 9 (9%) and 336 +/- 3 days; Station B, 8 (10%) and 244 +/- 13 days; Station C, 20 (26%) and 231 +/- 3 days. Treatment with high-dose GnRH agonist prevented pregnancies for longer (approximately 300 days) than treatment with low-dose GnRH agonist (approximately 200 days). In the majority of heifers and cows treated with GnRH agonist, ovarian follicular growth was restricted to early antral follicles (2-4mm). The findings indicate that GnRH agonist implants have considerable potential as a practical technology to suppress ovarian activity and control reproduction in female cattle maintained in extensive rangelands environments. The technology also has broader applications in diverse cattle production systems. Copyright 2002 Elsevier Science B.V.

  12. Long-term prospective cohort study on dental implants: clinical and microbiological parameters.

    PubMed

    Tenenbaum, Henri; Bogen, Omer; Séverac, François; Elkaim, René; Davideau, Jean-Luc; Huck, Olivier

    2017-01-01

    The aim of the present prospective cohort study is to evaluate clinical and microbiological data of dental implants after at least 8 years of follow-up. A total of 110 patients and 232 implants were included at baseline and followed during 1 year. Fifty-two patients and 108 implants could be evaluated at the final examination. Clinical and microbiological data were taken at baseline, 1 year and at least 8 years. The mean follow-up time was 10.8 ± 1.7 years. Plaque index was, respectively, 0.50 ± 0.50 at baseline, 0.50 ± 0.50 at 1 year and 0.33 ± 0.67 at ≥8 years. Gingival index was, respectively, 1.08 ± 0.19 at baseline, 1.01 ± 0.39 at 1 year and 0.22 ± 0.47 at ≥8 years. Sulcular bleeding index was, respectively, 0.17 ± 0.22 at baseline, 0.11 ± 0.33 at 1 year and 0.17 ± 0.22 at ≥8 years. Probing depth was, respectively, 2.67 ± 0.75 at baseline, 3.00 ± 0.83 at 1 year and 2.74 ± 1.00 at ≥8 years. Clinical attachment level was, respectively, 3.75 ± 1.17 at baseline, 4.00 ± 1.06 at 1 year and 4.00 ± 1.17 at ≥8 years. Peri-implant mucositis was detected around 60.2% of implants in 73.1% of patients, while peri-implantitis was affecting 12% of implants in 15.4% of patients. Some bacteria species were associated with worsened clinical parameters. About 69.4% of implants (75/108) and 67.3% of the patients (35/52) were considered as success in the present prospective cohort study after a mean follow-up of 10.8 years. Microbial follow-up may help to identify patients at risk for peri-implant disease. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Highly Sensitive and Long Term Stable Electrochemical Microelectrodes for Implantable Glucose Monitoring Devices

    NASA Astrophysics Data System (ADS)

    Qiang, Liangliang

    A miniature wireless implantable electrochemical glucose system for continuous glucose monitoring with good selectivity, sensitivity, linearity and long term stability was developed. First, highly sensitive, long-term stable and reusable planar H2O2 microelectrodes have been fabricated by microlithography. These electrodes composed of a 300 nm Pt black layer situated on a 5 um thick Au layer, provide effective protection to the underlying chromium adhesion layer. Using repeated cyclic voltammetric sweeps in flowing buffer solution, highly sensitive Pt black working electrodes were realized with five-decade linear dynamic range and low detection limit (10 nM) for H2O2 at low oxidation potentials. Second, a highly sensitive, low cost and flexible microwire biosensor was described using 25-mum thick gold wire as working electrode together with 125-mum thick Pt/Ir and Ag wires as counter and reference electrode, embedded within a PDMS-filled polyethylene tube. Surface area and activity of sensor was enhanced by converting gold electrode to nanoporous configuration followed by electrodeposition of platinum black. Glucose oxidase based biosensors by electrodeposition of poly(o-phenylenediamine) and glucose oxidase on the working electrode, displayed a higher glucose sensitivity (1.2 mA mM-1 cm-2) than highest literature reported. In addition it exhibits wide detection range (up to 20 mM) and selectivity (>95%). Third, novel miniaturized and flexible microelectrode arrays with 8 of 25 mum electrodes displayed the much needed 3D diffusion profiles similar to a single 25 mum microelectrode, but with one order increase in current levels. These microelectrode arrays displayed a H2O2 sensitivity of 13 mA mM-1 cm-2, a wide dynamic range of 100 nM to 10 mM, limit of detection of 10 nM. These microwire based edge plane microsensors incorporated flexibility, miniaturization and low operation potential are an promising approach for continuous in vivo metabolic monitoring. Fourth

  14. Remote monitoring to Improve long-term prognosis in heart failure patients with implantable cardioverter-defibrillators.

    PubMed

    Ono, Maki; Varma, Niraj

    2017-05-01

    Strong evidence exists for the utility of remote monitoring in cardiac implantable electronic devices for early detection of arrhythmias and evaluation of system performance. The application of remote monitoring for the management of chronic disease such as heart failure has been an active area of research. Areas covered: This review aims to cover the latest evidence of remote monitoring of implantable cardiac defibrillators in terms of heart failure prognosis. This article also updates the current technology relating to the method and discusses key factors to be addressed in order to better use the approach. PubMed and internet searches were conducted to acquire most recent data and technology information. Expert commentary: Multiparameter monitoring with automatic transmission is useful for heart failure management. Improved adherence to remote monitoring and an optimal algorithm for transmitted alerts and their management are warranted in the management of heart failure.

  15. Long-term outcomes of bone augmentation on soft and hard-tissue stability: a systematic review.

    PubMed

    Lutz, Rainer; Neukam, Friedrich W; Simion, Massimo; Schmitt, Christian M

    2015-09-01

    Peri-implant hard-tissue augmentation is a widely used clinical procedure. The present review aimed to analyse the current literature regarding medium- and long-term data concerning the stability of peri-implant tissues after hard-tissue augmentation prior or immediately with implant placement. An electronic literature search was performed using Medline (PubMed) databases detecting clinical studies focusing on hard- and soft-tissue stability around dental implants placed either in augmented alveolar ridges or simultaneously with peri-implant bone grafting. The search was limited to articles published between 1995 and December 2014, focusing on clinical studies with a prospective study design assessing peri-implant bone and soft tissue stability over time with a minimum follow-up of 12 months. Recent publications were also searched manually to find any relevant studies that might have been missed using the search criteria noted above. Thirty-seven articles met the inclusion criteria and were included in this systematic review. Since the outcome measures and methods, as well as types of grafts and implants used were so heterogeneous, the performance of meta-analysis was impossible. The highest level of evidence was achieved by randomized clinical trials. Different hard-tissue augmentation procedures seem to show stable peri-implant tissues, although, up to now, long-term stability of the augmented buccal bone is assessed by only few studies. Further research should concentrate on combining three-dimensional radiographic data with non-invasive methods as digital surface measuring techniques or ultrasound evaluation. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Elders with implant overdentures: a 22-year clinical report.

    PubMed

    Alsabeeha, Nabeel H M

    2012-09-01

    To report on the long-term survival and prosthodontic maintenance of two edentulous adults with mandibular overdentures supported by hydroxyapatite (HA)-coated implants. Mandibular implant overdentures are a successful treatment option with positive impact on the quality of life of elderly edentulous adults. Long-term survival of the implants requires continued rigorous prosthodontic maintenance. Two elderly edentulous adults with mandibular overdentures supported by 2 HA-coated implants were presented for prosthodontic rehabilitation after 22 years of placement. The implants were osseo-integrated and surviving at presentation based on accepted criteria. The mandibular implant overdentures suffered recurrent loss of retention and stability. Prosthodontic treatment involving the replacement of defective attachment systems and construction of new sets of mandibular implant overdentures opposing complete maxillary dentures is presented. The long-term survival of mandibular 2-implant overdentures requires continued prosthodontic maintenance. A conservative approach in the rehabilitation of two older edentulous adults with mandibular 2-implant overdentures was described including proper selection of attachment systems. © 2012 The Gerodontology Society and John Wiley & Sons A/S.

  17. Round window vibroplasty: long-term results.

    PubMed

    Böheim, Klaus; Mlynski, Robert; Lenarz, Thomas; Schlögel, Max; Hagen, Rudolf

    2012-10-01

    The round window (RW) approach in the use of the Vibrant Soundbridge(®) (VSB) is a safe and effective treatment of conductive and mixed hearing losses for a period of more than 3 years of device use. To investigate the long-term safety and efficacy as well as user satisfaction of patients with conductive and mixed hearing losses implanted with the VSB using RW vibroplasty. Twelve patients with conductive and mixed hearing losses were evaluated after 40 months of daily VSB use. Safety was assessed by evaluating reports of postoperative medical and surgical complications as well as by changes in bone conduction hearing thresholds. Efficacy outcome measures included aided and unaided hearing thresholds, speech recognition in quiet and in noise and subjective benefit questionnaires. The safety results revealed no significant medical complications. One subject experienced sudden hearing loss after 18-24 months of device use, but still continues to wear the device to her satisfaction. With regard to efficacy, there were no significant changes from short- to long-term results in aided word understanding, functional gain or speech recognition threshold, suggesting that the outcomes are stable over time. Subjective questionnaires revealed either the same or better results compared with the short-term data.

  18. Are Multidimensional Pain Inventory Coping Strategy Profiles Associated with Long-Term Spinal Cord Stimulation Effectiveness?

    PubMed

    Paroli, Mery; Bernini, Olivia; De Carolis, Giuliano; Tollapi, Lara; Bondi, Franca; Martini, Antonella; Dario, Alessandro; Paolicchi, Adriana

    2018-05-01

    It is acknowledged that the way patients cope with pain may influence treatment outcome. In particular, psychological factors are deemed important when considering patients for suitability for spinal cord stimulation (SCS). The aim of the study is to observe how pre-implantation psychological characteristics impact the effectiveness of SCS for chronic pain. The analysis comprised data from 137 patients who underwent an SCS implant. Screening evaluation included a coping strategies profile (Multidimensional Pain Inventory) and psychiatric disorders (Mini-International Neuropsychiatric Interview). Based on SCS implant outcome collected during follow-up visits, patients were divided into three groups: subjects with long-term pain relief (long-term group), subjects who failed the SCS treatment and decided to explant trial device (trial explanter group [TE]), and those who chose a permanent device (permanent explanter group [PE]). Results showed that most of the patients who failed with the SCS (TE and PE groups) demonstrated a dysfunctional coping profile and showed a higher presence of psychiatric disorders, which significantly influenced the experience and perception of pain. The findings of this study support the value of a multidisciplinary screening. Addressing psychological issues before SCS implantation can reduce the failure rate of SCS.

  19. Periodontal and periimplant maintenance: a critical factor in long-term treatment success.

    PubMed

    Shumaker, Nicholas D; Metcalf, Brett T; Toscano, Nicholas T; Holtzclaw, Dan J

    2009-09-01

    Periodontal maintenance (PM) is a critical factor in the long-term success of both periodontal and dental implant therapy. Studies have shown both modern periodontal and dental implant therapies are effective in maintaining natural teeth and replacing lost teeth, respectively. However, without a regular program of clinical reevaluation, plaque control, oral hygiene instruction, and reassessment of biomechanical factors, the benefits of treatment often are lost and inflammatory disease in the form of recurrent periodontitis or periimplantitis may result. This article reviews the goals, types, and appropriate frequency of PM in periodontal and dental implant therapy, as well as the incidence and etiology of periimplant disease and strategies for management when recurrent disease develops during the maintenance phase of treatment.

  20. Long-Term Durability of Bioprosthetic Aortic Valves: Implications From 12,569 Implants

    PubMed Central

    Johnston, Douglas R.; Soltesz, Edward G.; Vakil, Nakul; Rajeswaran, Jeevanantham; Roselli, Eric E.; Sabik, Joseph F.; Smedira, Nicholas G.; Svensson, Lars G.; Lytle, Bruce W.; Blackstone, Eugene H.

    2016-01-01

    Background Increased life expectancy and younger patients’ desire to avoid lifelong anticoagulation requires a better understanding of bioprosthetic valve failure. This study evaluates risk factors associated with explantation for structural valve deterioration (SVD) in a long-term series of Carpentier-Edwards PERIMOUNT aortic valves (AV). Methods From June 1982 to January 2011, 12,569 patients underwent AV replacement with Edwards Lifesciences Carpentier-Edwards PERIMOUNT stented bovine pericardial prostheses, models 2700PM (n = 310) or 2700 (n = 12,259). Mean age was 71 ± 11 years (range, 18 to 98 years). 93% had native AV disease, 48% underwent concomitant coronary artery bypass grafting, and 26% had additional valve surgery. There were 81,706 patient-years of systematic follow-up data available for analysis. Demographics, intraoperative variables, and 27,386 echocardiographic records were used to identify risks for explant for SVD and assess longitudinal changes in transprosthesis gradients using time-varying covariable analyses. Results Three hundred fifty-four explants were performed, with 41% related to endocarditis and 44% to SVD. Actuarial estimates of explant for SVD at 10 and 20 years were 1.9% and 15% overall, respectively, and in patients younger than 60 years, 5.6% and 46%, respectively. Younger age (p < 0.0001), lipid-lowering drugs (p = 0.002), prosthesis–patient mismatch (p = 0.001), and higher postoperative peak and mean AV gradients were associated with explant for SVD (p < 0.0001). The effect of gradient on SVD was greatest in patients younger than 60 years. Conclusions Durability of the Carpentier-Edwards PERIMOUNT aortic valve is excellent even in younger patients. Explant for SVD is related to gradient at implantation, especially in younger patients. Strategies to reduce early postoperative AV gradients, such as root enlargement or more efficient prostheses, should be considered. PMID:25662439

  1. Visual activity predicts auditory recovery from deafness after adult cochlear implantation.

    PubMed

    Strelnikov, Kuzma; Rouger, Julien; Demonet, Jean-François; Lagleyre, Sebastien; Fraysse, Bernard; Deguine, Olivier; Barone, Pascal

    2013-12-01

    Modern cochlear implantation technologies allow deaf patients to understand auditory speech; however, the implants deliver only a coarse auditory input and patients must use long-term adaptive processes to achieve coherent percepts. In adults with post-lingual deafness, the high progress of speech recovery is observed during the first year after cochlear implantation, but there is a large range of variability in the level of cochlear implant outcomes and the temporal evolution of recovery. It has been proposed that when profoundly deaf subjects receive a cochlear implant, the visual cross-modal reorganization of the brain is deleterious for auditory speech recovery. We tested this hypothesis in post-lingually deaf adults by analysing whether brain activity shortly after implantation correlated with the level of auditory recovery 6 months later. Based on brain activity induced by a speech-processing task, we found strong positive correlations in areas outside the auditory cortex. The highest positive correlations were found in the occipital cortex involved in visual processing, as well as in the posterior-temporal cortex known for audio-visual integration. The other area, which positively correlated with auditory speech recovery, was localized in the left inferior frontal area known for speech processing. Our results demonstrate that the visual modality's functional level is related to the proficiency level of auditory recovery. Based on the positive correlation of visual activity with auditory speech recovery, we suggest that visual modality may facilitate the perception of the word's auditory counterpart in communicative situations. The link demonstrated between visual activity and auditory speech perception indicates that visuoauditory synergy is crucial for cross-modal plasticity and fostering speech-comprehension recovery in adult cochlear-implanted deaf patients.

  2. Long-term results with the Atlas IIIp elastic cementless acetabular component in total hip replacement.

    PubMed

    Lee, Paul Yuh Feng; Rachala, Madhu; Teoh, Kar Ho; Woodnutt, David John

    2016-09-01

    Modular cementless elastic acetabular systems have advantages over cemented and hard shell cementless acetabular systems. There are few reports on the medium-term and long-term follow up of this particular type of implant. This study describes our experience with the Atlas IIIp modular acetabular system, which is a thin shell cementless elastic acetabular implant for total hip replacement commercialized under this name in many countries. We prospectively followed 244 patients treated with Atlas IIIp acetabular system between 2001 and 2004. Minimum ten year follow up was available for 148 hips (139 patients) from the original cohort of 263 hips (244 patients). One hundred five patients had died from unrelated causes and were excluded from the results. Post-operative and follow up radiographs of patients were assessed; and Harris hip scores were used as clinical outcome. Revision for any reason was defined as the end point for survivorship analysis. The mean pre-operative Harris hip score was 48 (S.D. 16) and the average post-operative score was 82 (S.D. 12). The mean follow up in our series was 11.5 years, ranging from ten to 13.5 years. Thirteen hips required further surgery in our cohort; of which ten cases required cup revision. The 13-years cumulative implant survival was 91.2 % and the risk of implant revision was 8.8 % at 13 years in 148 hips (139 patients). Kaplan-Meier analysis showed the implant survival rate of 95.2 % at ten years for revision for any reason and 99.4 % for aseptic loosening. Our clinical experience with this acetabular cup suggests good long-term survival rates that are similar to other cups on the market. The clinical experience in this study shows long-term survival rates that are consistent, acceptable and good results achieved with a low revision rate. Therapeutic III; therapeutic study.

  3. Peripheral arteriovenous fistula as vascular access for long-term chemotherapy.

    PubMed

    Kovalyov, Oleksiy O; Kostyuk, Oleksandr G; Tkachuk, Tetyana V

    To provide long-term vascular access in clinical oncology peripheral forearm veins (up to 95% of patients in Ukraine), central venous access and "complete implanted vascular systems" are used most often. Many oncology patients have contraindications to catheterization of superior vena cava. Besides, exploitation of central veins is associated with potential technical and infectious complications. The aim - to study short-term and long-term results of arteriovenous fistula exploitation as vascular access for continuous anticancer therapy. Peripheral venous bed status in 41 oncology patients taking long-term chemotherapy treatment is analyzed in the article. Doppler sonography, morphologic and immune histochemical analyses were used in the study. Doppler sonography found qualitative and quantitative changes in forearm veins at different time periods after initiation of chemotherapy in the majority of patients. The major morphologic manifestations of venous wall damage were chemical phlebitis, local or extended hardening of venous wall, venous thrombosis and extravasations with necrosis and subsequent paravasal tissue sclerosis. Alternative vascular access created in 12 patients completely met the adequacy criteria (safety, multiple use, longevity, realization of the designed therapy program). The conclusion was made about inapplicability of forearm veins for long-term administration of cytostatic agents. If it is impossible to use central veins, arteriovenous fistula can become an alternative vascular access.

  4. Telemetric implantable pressure sensor for short- and long-term monitoring of intracranial pressure.

    PubMed

    Frischholz, M; Sarmento, L; Wenzel, M; Aquilina, K; Edwards, R; Coakham, H B

    2007-01-01

    Patients with hydrocephalus, idiopathic intracranial hypertension and head injury frequently require monitoring of intracranial pressure (ICP) and may need repeated episodes of monitoring months or years apart. The gold standard for measurement of ICP remains the external ventricular catheter. This is a fluid-filled catheter transducer system that allows regular recalibration and correction of zero drift by its position relative to a fixed anatomical reference. It also allows drainage of cerebrospinal fluid (CSF), providing a means of lowering the ICP. Several catheter tip transducer systems are currently in clinical use, including using strain gauges or fiber-optical pressure sensing techniques. In these devices, zero drift and calibration cannot be checked in vivo. All the ICP monitoring devices in current clinical use require a physical connection between the brain and the external environment. This is a source of infection and limits the duration of monitoring. A number of telemetric monitoring devices, in which data is in some way transmitted transcutaneously, have been developed over the last twenty years, but significant technical problems have precluded their use in routine clinical practice. All current ICP monitors are temporary percutaneous implanted devices. Placement of these devices carries significant morbidity, particularly infection. Patients undergoing repeated monitoring require multiple surgical procedures. Apart from decreasing the risk of infection in patients with severe head injury, the clinical value of an accurate telemetric ICP monitoring system which maintains its reliability over a long period of implantation is high.

  5. Magnetic Beads Enhance Adhesion of NIH 3T3 Fibroblasts: A Proof-of-Principle In Vitro Study for Implant-Mediated Long-Term Drug Delivery to the Inner Ear

    PubMed Central

    Aliuos, Pooyan; Schulze, Jennifer; Schomaker, Markus; Reuter, Günter; Stolle, Stefan R. O.; Werner, Darja; Ripken, Tammo; Lenarz, Thomas; Warnecke, Athanasia

    2016-01-01

    Introduction Long-term drug delivery to the inner ear may be achieved by functionalizing cochlear implant (CI) electrodes with cells providing neuroprotective factors. However, effective strategies in order to coat implant surfaces with cells need to be developed. Our vision is to make benefit of electromagnetic field attracting forces generated by CI electrodes to bind BDNF-secreting cells that are labelled with magnetic beads (MB) onto the electrode surfaces. Thus, the effect of MB-labelling on cell viability and BDNF production were investigated. Materials and Methods Murine NIH 3T3 fibroblasts—genetically modified to produce BDNF—were labelled with MB. Results Atomic force and bright field microscopy illustrated the internalization of MB by fibroblasts after 24 h of cultivation. Labelling cells with MB did not expose cytotoxic effects on fibroblasts and allowed adhesion on magnetic surfaces with sufficient BDNF release. Discussion Our data demonstrate a novel approach for mediating enhanced long-term adhesion of BDNF-secreting fibroblasts on model electrode surfaces for cell-based drug delivery applications in vitro and in vivo. This therapeutic strategy, once transferred to cells suitable for clinical application, may allow the biological modifications of CI surfaces with cells releasing neurotrophic or other factors of interest. PMID:26918945

  6. Hyaline cartilage regeneration by combined therapy of microfracture and long-term bone morphogenetic protein-2 delivery.

    PubMed

    Yang, Hee Seok; La, Wan-Geun; Bhang, Suk Ho; Kim, Hak-Jun; Im, Gun-Il; Lee, Haeshin; Park, Jung-Ho; Kim, Byung-Soo

    2011-07-01

    Microfracture of cartilage induces migration of bone-marrow-derived mesenchymal stem cells. However, this treatment often results in fibrocartilage regeneration. Growth factors such as bone morphogenetic protein (BMP)-2 induce the differentiation of bone-marrow-derived mesenchymal stem cells into chondrocytes, which can be used for hyaline cartilage regeneration. Here, we tested the hypothesis that long-term delivery of BMP-2 to cartilage defects subjected to microfracture results in regeneration of high-quality hyaline-like cartilage, as opposed to short-term delivery of BMP-2 or no BMP-2 delivery. Heparin-conjugated fibrin (HCF) and normal fibrin were used as carriers for the long- and short-term delivery of BMP-2, respectively. Rabbit articular cartilage defects were treated with microfracture combined with one of the following: no treatment, fibrin, short-term delivery of BMP-2, HCF, or long-term delivery of BMP-2. Eight weeks after treatment, histological analysis revealed that the long-term delivery of BMP-2 group (microfracture + HCF + BMP-2) showed the most staining with alcian blue. A biochemical assay, real-time polymerase chain reaction assay and Western blot analysis all revealed that the long-term delivery of BMP-2 group had the highest glucosaminoglycan content as well as the highest expression level of collagen type II. Taken together, the long-term delivery of BMP-2 to cartilage defects subjected to microfracture resulted in regeneration of hyaline-like cartilage, as opposed to short-term delivery or no BMP-2 delivery. Therefore, this method could be more convenient for hyaline cartilage regeneration than autologous chondrocyte implantation due to its less invasive nature and lack of cell implantation.

  7. Phosphodiesterase 10A inhibition attenuates sleep deprivation-induced deficits in long-term fear memory.

    PubMed

    Guo, Lengqiu; Guo, Zhuangli; Luo, Xiaoqing; Liang, Rui; Yang, Shui; Ren, Haigang; Wang, Guanghui; Zhen, Xuechu

    2016-12-02

    Sleep, particularly rapid eye movement (REM) sleep, is implicated in the consolidation of emotional memories. In the present study, we investigated the protective effects of a phosphodiesterase 10A (PDE10A) inhibitor MP-10 on deficits in long-term fear memory induced by REM sleep deprivation (REM-SD). REM-SD caused deficits in long-term fear memory, however, MP-10 administration ameliorated the deleterious effects of REM-SD on long term fear memory. Brain-derived neurotropic factor (BDNF) and phosphorylated cAMP response element-binding protein (pCREB) were altered in specific brain regions associated with learning and memory in REM-SD rats. Accordingly, REM-SD caused a significant decrease of pCREB in hippocampus and striatum and a significant decrease of BDNF in the hippocampus, striatum and amygdala, however, MP-10 reversed the effects of REM-SD in a dose-dependent manner. Our findings suggest that REM-SD disrupts the consolidation of long-term fear memory and that administration of MP-10 protects the REM-SD-induced deficits in fear memory, which may be due to the MP-10-induced expression of BDNF in the hippocampus, striatum and amygdala, and phosphorylation of CREB in the hippocampus and striatum. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  8. Inverse Relationship of Blood Pressure to Long-Term Outcomes and Benefit of Cardiac Resynchronization Therapy in Patients With Mild Heart Failure: A Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy Long-Term Follow-Up Substudy.

    PubMed

    Biton, Yitschak; Moss, Arthur J; Kutyifa, Valentina; Mathias, Andrew; Sherazi, Saadia; Zareba, Wojciech; McNitt, Scott; Polonsky, Bronislava; Barsheshet, Alon; Brown, Mary W; Goldenberg, Ilan

    2015-09-01

    Previous studies have shown that low blood pressure is associated with increased mortality and heart failure (HF) in patients with left ventricular dysfunction. Cardiac resynchronization therapy (CRT) was shown to increase systolic blood pressure (SBP). Therefore, we hypothesized that treatment with CRT would provide incremental benefit in patients with lower SBP values. The independent contribution of SBP to outcome was analyzed in 1267 patients with left bundle brunch block enrolled in Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy (MADIT-CRT). SBP was assessed as continuous measures and further categorized into approximate quintiles. The risk of long-term HF or death and CRT with defibrillator versus implantable cardioverter defibrillator benefit was assessed in multivariate Cox proportional hazards regression models. Multivariate analysis showed that in the implantable cardioverter defibrillator arm, each 10-mm Hg decrement of SBP was independently associated with a significant 21% (P<0.001) increased risk for HF or death, and patients with lower quintile SBP (<110 mm Hg) experienced a corresponding >2-fold risk-increase. CRT with defibrillator provided the greatest HF or mortality risk reduction in patients with SBP<110 mm Hg hazard ratio of 0.34, P<0.001, when compared with hazard ratio of 0.52, P<0.001, in those with 110>SBP≥136 mm Hg and hazard ratio of 0.94, P=0.808, with SBP>136 mm Hg (P for trend=0.001). In patients with mild HF, prolonged QRS, and left bundle brunch block, low SBP is related to higher risk of mortality or HF with implantable cardioverter defibrillator therapy alone. Treatment with CRT is associated with incremental clinical benefits in patients with lower baseline SBP values. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00180271. © 2015 American Heart Association, Inc.

  9. Long-Term Survival in Patients Receiving a Continuous-Flow Left Ventricular Assist Device.

    PubMed

    Gosev, Igor; Kiernan, Michael S; Eckman, Peter; Soleimani, Behzad; Kilic, Ahmet; Uriel, Nir; Rich, Jonathan D; Katz, Jason N; Cowger, Jennifer; Lima, Brian; McGurk, Siobhan; Brisco-Bacik, Meredith A; Lee, Sanjin; Joseph, Susan M; Patel, Chetan B

    2018-03-01

    Long-term survivors after implantation of left ventricular assist devices (LVADs) are increasing in prevalence. We describe the characteristics and outcomes in patients surviving longer than 4 years on LVAD support. We performed a multicenter, retrospective analysis of patients surviving at least 4 years on continuous-flow LVAD (CF-LVAD) support with a HeartMate II at centers participating in the Evolving Mechanical support Research Group. Between 2005 and 2010, 156 long-term survivors were identified with a mean survival of 7.1 years (95% confidence interval: 6.7 to 7.5 years). The mean age was 58.2 ± 15.2 years and 30.1% were women. Readmission rate was low at 1.1 events per patient per year with the most common reasons leading to readmission being infection (0.10 readmissions per patient per year) and gastrointestinal bleeding (0.07 readmissions per patient per year). Two years after implantation, 97% of patients were either New York Heart Association functional class I or II, with 92% at 4 years. Patients surviving 4 years on CF-LVAD support can anticipate ongoing long-term survival with sustained improvements in functionality and low rates of rehospitalization. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Profiling deleterious non-synonymous SNPs of smoker's gene CYP1A1.

    PubMed

    Ramesh, A Sai; Khan, Imran; Farhan, Md; Thiagarajan, Padma

    2013-01-01

    CYP1A1 gene belongs to the cytochrome P450 family and is known better as smokers' gene due to its hyperactivation as a consequence of long term smoking. The expression of CYP1A1 induces polycyclic aromatic hydrocarbon production in the lungs, which when over expressed, is known to cause smoking related diseases, such as cardiovascular pathologies, cancer, and diabetes. Single nucleotide polymorphisms (SNPs) are the simplest form of genetic variations that occur at a higher frequency, and are denoted as synonymous and non-synonymous SNPs on the basis of their effects on the amino acids. This study adopts a systematic in silico approach to predict the deleterious SNPs that are associated with disease conditions. It is inferred that four SNPs are highly deleterious, among which the SNP with rs17861094 is commonly predicted to be harmful by all tools. Hydrophobic (isoleucine) to hydrophilic (serine) amino acid variation was observed in the candidate gene. Hence, this investigation aims to characterize a candidate gene from 159 SNPs of CYP1A1.

  11. [Immediate and Long-term Results of the First in Russia of IntrocoronaryMetal Stent in the Coronary Artery].

    PubMed

    Babunashvili, A M; Navtsishvili, Z G; Konstantinov, B A

    2016-02-01

    The authors present immediate and long term results of the first in Russia implantation in coronary artery of Palmaz-Shatz metal stent. Indications for stenting were urgent after complicated dissection as a result of balloon dilation of discrete bifurcational stenosis of anterior interventricular artery (IVA). Immediate angiographic and clinical result was good. At control angiography after 13 years their was no restenosis in stented IVA. However novel narrowing was found in left main coronary artery (LMCA) in which drug eluting stent was implanted. Coronary angiography carried out after 7.5 years after stenting of LMCA and in 20 years after stent implantation in IVA revealed good patency of both stented segments without signs of restenosis. This case report demonstrates possibility of long term preservation of angiographic and clinical effect of staged endovascular treatment of coronary atherosclerosis.

  12. New 3D technologies applied to assess the long-term clinical effects of misfit of the full jaw fixed prosthesis on dental implants.

    PubMed

    Jokstad, Asbjørn; Shokati, Babak

    2015-10-01

    metrological software. The effect of misfit between the superstructures on its supporting implants up to ~230 μm on the long-term clinical outcomes appears to be minor, apart from a slightly higher risk of screw-related adverse events. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Long-term follow-up of sacral neuromodulation for lower urinary tract dysfunction.

    PubMed

    Peeters, Karlien; Sahai, Arun; De Ridder, Dirk; Van Der Aa, Frank

    2014-05-01

    To report our long-term experience of sacral neuromodulation (SNM) for various lower urinary tract dysfunctions but with a focus on efficacy, safety, re-interventions and degree of success. This is a single tertiary referral centre study that included 217 patients (86% female) who received an implantable pulse generator (IPG) (Interstim™, Medtronic, Minneapolis, USA) between 1996 and 2010. Success was considered if the initial ≥50% improvement in any of primary voiding diary variables persisted compared with baseline, but was further stratified. The mean duration of follow-up was 46.88 months. Success and cure rates were ≈70% and 20% for urgency incontinence, 68% and 33% for urgency frequency syndrome and 73% and 58% for idiopathic retention. In those patients with an unsuccessful therapy outcome, the mean time to failure was 24.6 months after implantation. There were 88 (41%) patients who had at least one device or treatment related surgical re-intervention. The re-intervention rate was 1.7 per patient with most of them (47%) occurring ≤2 years of follow-up. SNM appears effective in the long-term with a success rate after definitive IPG implant of ≈70% and complete cure rates ranging between 20% and 58% depending on indication. Patients with idiopathic retention appear to do best. The re-intervention rate is high with most occurring ≤2 years of implantation. It is likely that with the newer techniques used, efficacy and re-intervention rates will improve. © 2013 The Authors. BJU International © 2013 BJU International.

  14. Application of long-term microdialysis in circadian rhythm research

    PubMed Central

    Borjigin, Jimo; Liu, Tiecheng

    2008-01-01

    Our laboratory has pioneered long-term microdialysis to monitor pineal melatonin secretion in living animals across multiple circadian cycles. There are numerous advantages of this approach for rhythm analysis: (1) we can precisely define melatonin onset and offset phases; (2) melatonin is a reliable and stable neuroendocrine output of the circadian clock (versus behavioral output which is sensitive to stress or other factors); (3) melatonin measurements can be performed extremely frequently, permitting high temporal resolution (10 min sampling intervals), which allows detection of slight changes in phase; (4) the measurements can be performed for more than four weeks, allowing perturbations of the circadian clock to be followed long-term in the same animals; (5) this is an automated process (microdialysis coupled with on-line HPLC analysis), which increases accuracy and bypasses the labor-intensive and error-prone manual handling of dialysis samples; and (6) our approach allows real-time investigation of circadian rhythm function and permits appropriate timely adjustments of experimental conditions. The longevity of microdialysis probes, the key to the success of this approach, depends at least in part on the methods of the construction and implantation of dialysis probes. In this article, we have detailed the procedures of construction and surgical implantation of microdialysis probes used currently in our laboratory, which are significantly improved from our previous methods. PMID:18045670

  15. Long-term effects of flipper bands on penguins

    USGS Publications Warehouse

    Gauthier-Clerc, M.; Gendner, J.-P.; Ribic, C.A.; Fraser, William R.; Woehler, Eric J.; Descamps, S.; Gilly, C.; Le, Bohec C.; Le, Maho Y.

    2004-01-01

    Changes in seabird populations, and particularly of penguins, offer a unique opportunity for investigating the impact of fisheries and climatic variations on marine resources. Such investigations often require large-scale banding to identify individual birds, but the significance of the data relies on the assumption that no bias is introduced in this type of long-term monitoring. After 5 years of using an automated system of identification of king penguins implanted with electronic tags (100 adult king penguins were implanted with a transponder tag, 50 of which were also flipper banded), we can report that banding results in later arrival at the colony for courtship in some years, lower breeding probability and lower chick production. We also found that the survival rate of unbanded, electronically tagged king penguin chicks after 2-3 years is approximately twice as large as that reported in the literature for banded chicks. ?? 2004 The Royal Society.

  16. Long-term prospective outcomes after minimally invasive trans-iliac sacroiliac joint fusion using triangular titanium implants.

    PubMed

    Darr, Emily; Meyer, S Craig; Whang, Peter G; Kovalsky, Don; Frank, Clay; Lockstadt, Harry; Limoni, Robert; Redmond, Andy; Ploska, Philip; Oh, Michael Y; Cher, Daniel; Chowdhary, Abhineet

    2018-01-01

    Minimally invasive sacroiliac joint fusion (SIJF) has become an increasingly accepted surgical option for chronic sacroiliac (SI) joint dysfunction, a prevalent cause of unremitting low back/buttock pain. The objective of this study was to report clinical and functional outcomes of SIJF using triangular titanium implants (TTI) in the treatment of chronic SI joint dysfunction due to degenerative sacroiliitis or sacroiliac joint (SIJ) disruption at 3 years postoperatively. A total of 103 subjects with SIJ dysfunction at 12 centers were treated with TTI in two prospective clinical trials (NCT01640353 and NCT01681004) and enrolled in this long-term follow-up study (NCT02270203). Subjects were evaluated in study clinics at study start and again at 3, 4, and 5 years. Mean (SD) preoperative SIJ pain score was 81.5, and mean preoperative Oswestry Disability Index (ODI) was 56.3. At 3 years, mean pain SIJ pain score decreased to 26.2 (a 55-point improvement from baseline, p <0.0001). At 3 years, mean ODI was 28.2 (a 28-point improvement from baseline, p <0.0001). In all, 82% of subjects were very satisfied with the procedure at 3 years. EuroQol-5D (EQ-5D) time trade-off index improved by 0.30 points ( p <0.0001). No adverse events definitely related to the study device or procedure were reported; one subject underwent revision surgery at year 3.7. SIJ pain contralateral to the originally treated side occurred in 15 subjects of whom four underwent contralateral SIJF. The proportion of subjects who were employed outside the home full- or part-time at 3 years decreased somewhat from baseline ( p =0.1814), and the proportion of subjects who would have the procedure again was lower at 3 years compared to earlier time points. In long-term (3-year) follow-up, minimally invasive trans-iliac SIJF with TTI was associated with improved pain, disability, and quality of life with relatively high satisfaction rates. Level II. SIJF with TTI.

  17. Long-term prospective outcomes after minimally invasive trans-iliac sacroiliac joint fusion using triangular titanium implants

    PubMed Central

    Darr, Emily; Meyer, S Craig; Whang, Peter G; Kovalsky, Don; Frank, Clay; Lockstadt, Harry; Limoni, Robert; Redmond, Andy; Ploska, Philip; Oh, Michael Y; Cher, Daniel; Chowdhary, Abhineet

    2018-01-01

    Background Minimally invasive sacroiliac joint fusion (SIJF) has become an increasingly accepted surgical option for chronic sacroiliac (SI) joint dysfunction, a prevalent cause of unremitting low back/buttock pain. Objective The objective of this study was to report clinical and functional outcomes of SIJF using triangular titanium implants (TTI) in the treatment of chronic SI joint dysfunction due to degenerative sacroiliitis or sacroiliac joint (SIJ) disruption at 3 years postoperatively. Methods A total of 103 subjects with SIJ dysfunction at 12 centers were treated with TTI in two prospective clinical trials (NCT01640353 and NCT01681004) and enrolled in this long-term follow-up study (NCT02270203). Subjects were evaluated in study clinics at study start and again at 3, 4, and 5 years. Results Mean (SD) preoperative SIJ pain score was 81.5, and mean preoperative Oswestry Disability Index (ODI) was 56.3. At 3 years, mean pain SIJ pain score decreased to 26.2 (a 55-point improvement from baseline, p<0.0001). At 3 years, mean ODI was 28.2 (a 28-point improvement from baseline, p<0.0001). In all, 82% of subjects were very satisfied with the procedure at 3 years. EuroQol-5D (EQ-5D) time trade-off index improved by 0.30 points (p<0.0001). No adverse events definitely related to the study device or procedure were reported; one subject underwent revision surgery at year 3.7. SIJ pain contralateral to the originally treated side occurred in 15 subjects of whom four underwent contralateral SIJF. The proportion of subjects who were employed outside the home full- or part-time at 3 years decreased somewhat from baseline (p=0.1814), and the proportion of subjects who would have the procedure again was lower at 3 years compared to earlier time points. Conclusion In long-term (3-year) follow-up, minimally invasive trans-iliac SIJF with TTI was associated with improved pain, disability, and quality of life with relatively high satisfaction rates. Level of evidence Level II

  18. Effect of long-term and short-term progestagen treatment on follicular development and pregnancy rate in cyclic ewes.

    PubMed

    Viñoles, C; Forsberg, M; Banchero, G; Rubianes, E

    2001-03-01

    The aim of this study was to evaluate the effect of the length of a progestagen treatment (12 d vs. 6 d) on follicular dynamics, estrus synchronization and pregnancy rate using medroxyprogesterone acetate (MAP) with or without an eCG dose at the end of MAP treatment. One hundred sixty Polwarth ewes were divided into four equal groups: long-term treated (LT, n=40); short-term treated (ST, n=40); long-term treated plus eCG (LTeCG, n=40); and short-term treated plus eCG (STeCG, n=40). Five ewes of each group were separated to undergo daily transrectal ultrasonography, and blood samples were taken for hormone determination. Until 96 h after sponge withdrawal the number of ewes in estrus was higher in both long-term-treated groups than in both short-term-treated groups but at the end of the observational period (144 h) no significant differences were found among groups. The pregnancy rate was higher in the ST group (87%) than in the other groups (LT, 63%; LTeCG, 67%; and STeCG, 58%; P< or =0.03). The ovulatory follicle emerged before sponge withdrawal in long-term-treated ewes (-3.8+/-0.4 d and -2.2+/-0.8 d for LT and LTeCG, respectively), whereas in short-term-treated ewes it emerges around sponge removal (0.4+/-1.1 d and 0.5+/-0.5 d for ST and STeCG, respectively; P< or =0.01). The ovulatory follicle in the LT group had a longer lifespan and attained a larger (P< or =0.05) maximum diameter than in the ST group. We conclude: a) that the lower pregnancy rate observed after long-term progestagen treatment was related to a slower follicular turnover that promoted the ovulation of persistent dominant follicles; (b) that short-term treatment resulted in a higher pregnancy rate probably due to the ovulation of newly recruited growing follicles; and (c) treatment with eCG had no advantage in association with long-term treatment and had a deleterious effect in combination with short-term treatment with MAP.

  19. Determination of metallic traces in kidneys, livers, lungs and spleens of rats with metallic implants after a long implantation time.

    PubMed

    Rubio, Juan Carlos; Garcia-Alonso, Maria Cristina; Alonso, Concepcion; Alobera, Miguel Angel; Clemente, Celia; Munuera, Luis; Escudero, Maria Lorenza

    2008-01-01

    Metallic transfer from implants does not stop at surrounding tissues, and metallic elements may be transferred by proteins to become lodged in organs far from the implant. This work presents an in vivo study of metallic implant corrosion to measure metallic element accumulation in organs located far from the implant, such as kidneys, livers, lungs and spleens. The studied metallic implant materials were CoCr alloy, Ti, and the experimental alloy MA956 coated with alpha-alumina. The implants were inserted in the hind legs of Wistar rats. Analysis for Co, Cr, Ti and Al metallic traces was performed after a long exposure time of 12 months by Inductively Coupled Plasma (ICP) with Mass Spectrometry (MS). According to the results, the highest Cr and Ti concentrations were detected in spleens. Co is mainly found in kidneys, since this element is eliminated via urine. Cr and Ti traces increased significantly in rat organs after the long implantation time. The organs of rats implanted with the alpha-alumina coated experimental MA956 did not present any variation in Al content after 12 months, which means there was no degradation of the alumina layer surface.

  20. Long-term outcome of cochlear implant in patients with chronic otitis media: one-stage surgery is equivalent to two-stage surgery.

    PubMed

    Jang, Jeong Hun; Park, Min-Hyun; Song, Jae-Jin; Lee, Jun Ho; Oh, Seung Ha; Kim, Chong-Sun; Chang, Sun O

    2015-01-01

    This study compared long-term speech performance after cochlear implantation (CI) between surgical strategies in patients with chronic otitis media (COM). Thirty patients with available open-set sentence scores measured more than 2 yr postoperatively were included: 17 who received one-stage surgeries (One-stage group), and the other 13 underwent two-stage surgeries (Two-stage group). Preoperative inflammatory status, intraoperative procedures, postoperative outcomes were compared. Among 17 patients in One-stage group, 12 underwent CI accompanied with the eradication of inflammation; CI without eradicating inflammation was performed on 3 patients; 2 underwent CIs via the transcanal approach. Thirteen patients in Two-stage group received the complete eradication of inflammation as first-stage surgery, and CI was performed as second-stage surgery after a mean interval of 8.2 months. Additional control of inflammation was performed in 2 patients at second-stage surgery for cavity problem and cholesteatoma, respectively. There were 2 cases of electrode exposure as postoperative complication in the two-stage group; new electrode arrays were inserted and covered by local flaps. The open-set sentence scores of Two-stage group were not significantly higher than those of One-stage group at 1, 2, 3, and 5 yr postoperatively. Postoperative long-term speech performance is equivalent when either of two surgical strategies is used to treat appropriately selected candidates.

  1. Long-term Calibration Considerations during Subcutaneous Microdialysis Sampling in Mobile Rats

    PubMed Central

    Mou, Xiaodun; Lennartz, Michelle; Loegering, Daniel J.; Stenken, Julie A.

    2010-01-01

    The level at which implanted sensors and sampling devices maintain their calibration is an important research area. In this work, microdialysis probes with identical geometry and different membranes, polycarbonate/polyether (PC) or polyethersulfone (PES), were used with internal standards (vitamin B12 (MW 1355), antipyrine (MW 188) and 2-deoxyglucose (2-DG, MW 164)) and endogenous glucose to investigate changes in their long-term calibration after implantation into the subcutaneous space of Sprague-Dawley rats. Histological analysis confirmed an inflammatory response to the microdialysis probes and the presence of a collagen capsule. The membrane extraction efficiency (percentage delivered to the tissue space) for antipyrine and 2-DG was not altered throughout the implant lifetime for either PC- or PES-membranes. Yet, Vitamin B12 extraction efficiency and collected glucose concentrations decreased during the implant lifetime. Antipyrine was administered i.v. and its concentrations obtained in both PC-and PES-membrane probes were significantly reduced between the implant day and seven (PC) or 10 (PES) days post implantation suggesting that solute supply is critical for in vivo extraction efficiency. For the low molecular weight solutes such as antipyrine and glucose, localized delivery is not affected by the foreign body reaction, but recovery is significantly reduced. For Vitamin B12, a larger solute, the fibrotic capsule formed around the probe significantly restricts diffusion from the implanted microdialysis probes. PMID:20223515

  2. Long-term Results for the BacJac Interspinous Device in Lumbar Spine Degenerative Disease.

    PubMed

    Spallone, Aldo; Lavorato, Luigi; Belvisi, Daniele

    2018-05-14

     To evaluate the long-term results of using the BacJac interspinous device (Pioneer Surgical Technology Inc.) in a series of patients with degenerative lumbar spine disease.  Forty-one patients undergoing lumbar surgery with implantation of a BacJac device from 2009 to 2012 were enrolled in the present study. Patients were evaluated using the Oswestry Disability Scale (ODI).  Although all patients showed a significant improvement of the ODI score immediately after surgery, only 41% of patients showed a satisfactory outcome. We observed worse results in the patients operated on at the L3-L4 level and in whom the device was implanted in a segment different from the one where surgical decompression had been performed. Weight gain in the months after surgery was also a poor outcome-influencing factor.  This study confirms what is already suggested in the relevant literature regarding the long-term inefficacy of the so-called dynamic stabilization devices. Georg Thieme Verlag KG Stuttgart · New York.

  3. [Long-term outcome of surgical revascularization in patients with ischemic heart disease and left ventricular dysfunction].

    PubMed

    Wang, R; Gao, C Q; Xiao, C S; Wu, Y; Ren, C L; Gong, Z Y; Wang, Y; Liu, G P; Wang, M Y

    2016-04-19

    To analyze the long-term results and risk factors of surgical revascularization in patients with ischemic heart disease (IHD) and left ventricular dysfunction (LVD). From January 2003 to July 2013, 2 132 patients underwent coronary artery bypass grafting (CABG) in our institution. Among them, 318 patients with LVD[left ventricular ejection fraction (LVEF) ≤50%]were included in the final study. There were 26 6 male and 52 female patients with age from 36 to 83 (63±9) years old. 76 patients underwent off-pump CABG (OPCAB) and 242 patients underwent conventional CABG (CCABG). Risk factors, perioperative results and follow-up data were collected and analyzed with cox hazard ratio model. Among 318 patients, 6 cases died of the operation with a hospital mortality of 1.9%. With follow-up time from 1 to 128(45.5±32.4)months, 25 patients were lost of follow-up, causing a follow-up rate of 92.0%. Among the 287 cases with long-term follow-up results, all-cause death, cardiogenic death and re-hospitalization due to heart failure were 14.6% (42/287), 5.9%(17/287), 14.6% (42/287), respectively. Re-revascularization rate, recurrent angina and myocardial infarction rate and cerebral incidence were 3.5%(10/287), 13.6% (39/287), 1.7%(5/287), respectively. The five-year survival rate was 85.6%. With all-cause death as the endpoint, preoperative LVEF (HR=0.943, 95%CI: 0.893-0.995, P=0.031) and perioperative implantation of IABP (HR=2.509, 95%CI: 1.051-5.992, P=0.038) emerged as the risk factors that affected the long term survival. The five-year survival rate of patients with severe LVD (LVEF≤35%) was significantly lower than that of patients with mild to moderate LVD (35%implantation of IABP had adverse effect on long-term survival of patients with IHD and LVD undergoing surgical revascularization. The long-term survival of patients with severe LVD was significantly lower than those with mild to

  4. Long-term bilayer encapsulation performance of atomic layer deposited Al₂O₃ and Parylene C for biomedical implantable devices.

    PubMed

    Xie, Xianzong; Rieth, Loren; Caldwell, Ryan; Diwekar, Mohit; Tathireddy, Prashant; Sharma, Rohit; Solzbacher, Florian

    2013-10-01

    We present an encapsulation scheme that combines atomic layer deposited (ALD) Al₂O₃ and Parylene C for the encapsulation of implantable devices. The encapsulation performances of combining alumina and Parylene C was compared to individual layers of Parylene C or alumina and the bilayer coating had superior encapsulation properties. The alumina-Parylene coated interdigitated electrodes (IDEs) soaked in PBS for up to nine months at temperatures from 37 to 80 °C for accelerated lifetime testing. For 52-nm alumina and 6-μm Parylene C, leakage current was ∼20 pA at 5 VDC, and the impedance was about 3.5 MΩ at 1 kHz with a phase near -87° from electrochemical impedance spectroscopy for samples soaked at 67 °C for equivalent lifetime of 72 months at 37 °C. The change of impedance during the whole soaking period (up to 70 months of equivalent soaking time at 37 °C) over 1 to 10⁶ Hz was within 5%. The stability of impedance indicated almost no degradation of the encapsulation. Bias voltage effect was studied by continuously applying 5 VDC, and it reduced the lifetime of Parylene coating by ∼75% while it showed no measurable effect on the bilayer coating. Lifetime of encapsulation of IDEs with topography generated by attaching a coil and surface mount device (SMD) capacitor was about half of that of planer IDEs. The stable long-term insulation impedance, low leakage current, and better lifetime under bias voltage and topography made this double-layer encapsulation very promising for chronic implantable devices.

  5. Using Aerospace Technology To Design Orthopedic Implants

    NASA Technical Reports Server (NTRS)

    Saravanos, D. A.; Mraz, P. J.; Davy, D. T.

    1996-01-01

    Technology originally developed to optimize designs of composite-material aerospace structural components used to develop method for optimizing designs of orthopedic implants. Development effort focused on designing knee implants, long-term goal to develop method for optimizing designs of orthopedic implants in general.

  6. Surgical Tooth Implants, Combat and Field.

    DTIC Science & Technology

    1984-07-15

    and identify by block number) --- This Annual Report summarizes progress to date on a long-term implant study of a serrated ceramic dental implant...upper two parts of the implant, post and core and crown, are conventional metaT materials. A series of graded dental implants have been produced to...throughout the experimental period. Periodic radio- graphic analyses of dental implants verify this observation. Gross and microscopic patho- logic analyses

  7. [Infectious complications of long term intravenous devices: incidence, risk factors, diagnostic tools].

    PubMed

    Douard, M C; Ardoin, C; Payri, L; Tarot, J P

    1999-03-01

    Implantable venous ports and Hickman central venous catheters are widely used in patients with cancer, blood disorders, or HIV infection, both for in-hospital care and at home. Infectious complications are among the common causes for readmission in these patients. The present review discusses the incidence, risk factors, and diagnostic tools for infectious complications associated with long-term venous access devices.

  8. Clinical and radiographical ten years long-term outcome of microfracture vs. autologous chondrocyte implantation: a matched-pair analysis.

    PubMed

    Ossendorff, Robert; Franke, Kilian; Erdle, Benjamin; Uhl, Markus; Südkamp, Norbert P; Salzmann, Gian M

    2018-06-16

    To compare the clinical and radiographical long-term outcome of microfracture (MFX) and first-generation periosteum-covered autologous chondrocyte implantation (ACI-P). All subjects (n = 86) who had been treated with knee joint ACI-P or microfracture (n = 76) with a post-operative follow-up of at least ten years were selected. Clinical pre- and post-operative outcomes were analyzed by numeric analog scale (NAS) for pain, Lysholm, Tegner, IKDC, and KOOS score. Radiographical evaluation was visualized by magnetic resonance imaging (MRI). Assessment of the regenerate quality was performed by the magnetic resonance observation of cartilage repair tissue (MOCART) and modified knee osteoarthritis scoring system (mKOSS). Relaxation time (RT) of T2 maps enabled a microstructural cartilage analysis. MFX and ACI of 44 patients (24 females, 20 males; mean age 38.9 ± 12.1 years) resulted in a good long-term outcome with low pain scores and significant improved clinical scores. The final Lysholm and functional NAS scores were significantly higher in the MFX group (Lysholm: MFX 82 ± 15 vs. ACI-P 71 ± 18 p = 0.027; NAS function: MFX 8.1 ± 3.5 vs. ACI-P 6.0 ± 2.5; p = 0.003). The MOCART score did not show any qualitative differences. KOSS analysis demonstrated that cartilage repair of small defects resulted in a significant better outcome. T2-relaxation times were without difference between groups at the region of the regenerate tissue. This study did not demonstrate coherent statistical differences between both cartilage repair procedures. MFX might be superior in the treatment of small cartilage defects.

  9. Concomitant tricuspid valve repair or replacement during left ventricular assist device implant demonstrates comparable outcomes in the long term.

    PubMed

    Deo, Salil V; Hasin, Tal; Altarabsheh, Salah E; McKellar, Stephen H; Shah, Ishan K; Durham, Lucian; Stulak, John M; Daly, Richard C; Park, Soon J; Joyce, Lyle D

    2012-11-01

    Severe tricuspid regurgitation (TR) is present in nearly half the patients undergoing implant of a left ventricular assist device (LVAD) and its correction confers better long-term outcome. To compare the early and late results of tricuspid valve repair (TVrpr) or replacement (TVR) with LVAD implant. Sixty-four from a cohort of 126 patients had a concomitant tricuspid valve procedure; 48 (75%) underwent a TVrpr whereas 16 (25%) had TVR. All preoperative hemodynamic parameters including the mean TR grade (TVrpr; 3.6 vs. TVR; 3.7) were comparable (p = 0.7). The mean TR grade was 1.6 ± 1.5 for the remaining 62 patients who did not have a concomitant tricuspid valve procedure, with 4/62 (6%) having severe TR (p < 0.0001). Cardiopulmonary bypass time was longer for patients undergoing TVR (p = 0.01). There was a significant reduction in right atrial pressure for the entire cohort (p < 0.01) and the postoperative right atrial pressure was not statistically different between TVrpr (13.6 ± 4.6) and TVR (11.6 ± 4.3; p = 0.6. Postoperative intensive care unit stay was comparable as was the duration of inotropic support (p = 0.5) or need for temporary right ventricular mechanical support. In-hospital mortality (12%) was not different between groups. The mean time for LVAD support was 12.3 ± 9.71 months and the last transthoracic echocardiographic examination was performed at mean intervals of 13.8 ± 10.8 months (TVrpr) and 11.8 ± 7.6 months (TVR; p = 0.47). Reduction in TR grade was similar between groups (p = 0.27). Late mortality (p = 1.00) was comparable in both groups. Using log-rank analysis, there was no significant difference in the estimated survival between TVrpr and TVR (p = 0.88). TVrpr repair at the time of LVAD implant is effective in correcting TR even at the end of one year of follow-up. The choice to repair or replace does not affect the clinical outcome. © 2012 Wiley Periodicals, Inc.

  10. The effect of gene interactions on the long-term response to selection.

    PubMed

    Paixão, Tiago; Barton, Nicholas H

    2016-04-19

    The role of gene interactions in the evolutionary process has long been controversial. Although some argue that they are not of importance, because most variation is additive, others claim that their effect in the long term can be substantial. Here, we focus on the long-term effects of genetic interactions under directional selection assuming no mutation or dominance, and that epistasis is symmetrical overall. We ask by how much the mean of a complex trait can be increased by selection and analyze two extreme regimes, in which either drift or selection dominate the dynamics of allele frequencies. In both scenarios, epistatic interactions affect the long-term response to selection by modulating the additive genetic variance. When drift dominates, we extend Robertson's [Robertson A (1960)Proc R Soc Lond B Biol Sci153(951):234-249] argument to show that, for any form of epistasis, the total response of a haploid population is proportional to the initial total genotypic variance. In contrast, the total response of a diploid population is increased by epistasis, for a given initial genotypic variance. When selection dominates, we show that the total selection response can only be increased by epistasis when some initially deleterious alleles become favored as the genetic background changes. We find a simple approximation for this effect and show that, in this regime, it is the structure of the genotype-phenotype map that matters and not the variance components of the population.

  11. Long-term outcomes of dental implants placed in elderly patients: a retrospective clinical and radiographic analysis.

    PubMed

    Park, Jung-Chul; Baek, Won-Sun; Choi, Seong-Ho; Cho, Kyoo-Sung; Jung, Ui-Won

    2017-02-01

    The aim of this retrospective study was to determine the clinical and the radiographic outcomes of dental implants placed in elderly people older than 65 years. In total, 902 implants in 346 patients (age: 65-89 years) were followed up for 2-17 years following the implant surgery. The survival rate of these implants was recorded and analyzed. Changes in marginal bone levels were also analyzed in serial radiographs, and Cox regression analysis for implant loss was performed. The survival rates were 95.39% and 99.98% in the implant- and patient-based analyses, respectively (involving a total of 29 implant failures), and the marginal bone loss at the implants was 0.17 ± 0.71 mm (mean ± SD). The number of failures was greatest in patients aged 65-69 years. The Cox regression with shared frailty analysis showed that implant loss was significantly greater in those aged 65-69 years than in those aged 70-74 years (P < 0.05), and it varied between specific implant systems. Within the limitations of this retrospective study, it was concluded that implant therapy can be successfully provided to elderly patients and that age alone does not seem to affect the implant survival rate. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. A Suprachoroidal Electrical Retinal Stimulator Design for Long-Term Animal Experiments and In Vivo Assessment of Its Feasibility and Biocompatibility in Rabbits

    PubMed Central

    Zhou, J. A.; Woo, S. J.; Park, S. I.; Kim, E. T.; Seo, J. M.; Chung, H.; Kim, S. J.

    2008-01-01

    This article reports on a retinal stimulation system for long-term use in animal electrical stimulation experiments. The presented system consisted of an implantable stimulator which provided continuous electrical stimulation, and an external component which provided preset stimulation patterns and power to the implanted stimulator via a paired radio frequency (RF) coil. A rechargeable internal battery and a parameter memory component were introduced to the implanted retinal stimulator. As a result, the external component was not necessary during the stimulation mode. The inductive coil pair was used to pass the parameter data and to recharge the battery. A switch circuit was used to separate the stimulation mode from the battery recharging mode. The implantable stimulator was implemented with IC chips and the electronics, except for the stimulation electrodes, were hermetically packaged in a biocompatible metal case. A polyimide-based gold electrode array was used. Surgical implantation into rabbits was performed to verify the functionality and safety of this newly designed system. The electrodes were implanted in the suprachoroidal space. Evoked cortical potentials were recorded during electrical stimulation of the retina. Long-term follow-up using OCT showed no chorioretinal abnormality after implantation of the electrodes. PMID:18317521

  13. Capture of intraocular lens optic by residual capsular opening in secondary implantation: long-term follow-up.

    PubMed

    Tian, Tian; Chen, Chunli; Jin, Haiying; Jiao, Lyu; Zhang, Qi; Zhao, Peiquan

    2018-04-02

    To introduce a novel surgical technique for optic capture by residual capsular opening in secondary intraocular lens (IOL) implantation and to report the outcomes of a long follow-up. Twenty patients (20 eyes) who had received secondary IOL implantation with the optic capture technique were retrospectively reviewed. We used the residual capsular opening for capturing the optic and inserted the haptics in the sulcus during surgery. Baseline clinical characteristics and surgical outcomes, including best-corrected visual acuity (BCVA), refractive status, and IOL position were recorded. The postoperative location and stability of IOL were evaluated using the ultrasound biomicroscopy. Optic capture technique was successfully performed in all cases, including 5 cases with large area of posterior capsular opacity, 6 cases with posterior capsular tear or rupture,and 9 cases with adhesive capsules. BCVA improved from 0.60 logMAR at baseline to 0.36 logMAR at the last follow-up (P < 0.001). Spherical equivalent changed from 10.67 ± 4.59 D at baseline to 0.12 ± 1.35 D at 6 months postoperatively (P < 0.001). Centered IOLs were observed in all cases and remained captured through residual capsular opening in 19 (95%) eyes at the last follow-up. In one case, the captured optic of IOL slid into ciliary sulcus at 7 months postoperatively. No other postoperative complications were observed in any cases. This optic capture technique by using residual capsule opening is an efficacious and safe technique and can achieve IOL stability in the long follow-up.

  14. Long-term follow-up of DDD pacing mode.

    PubMed

    Ulman, Mateusz; Dębski, Maciej; Ząbek, Andrzej; Haberka, Kazimierz; Lelakowski, Jacek; Małecka, Barbara

    2014-01-01

    The aim of this study was to determine the long-term survival of DDD pacing and identify the main reasons for its loss. The study group consisted of 496 patients in whom a DDD pacing system was implanted between October 1984 and March 2002 and who were followed up until July 2010. The follow-up period was 152.1 ± 35.5 months. The patients' mean age at the time of implantation was 59.5 ± 12.5 years, and 53.5% were male; 58% had sick sinus syndrome (SSS), 26% had atrioventricular block (AVB), 15% had both of these indications simultaneously, and 1% had other indications. The incidence of lead malfunction, progression to chronic atrial fibrillation (AF), and the rate of infective complications was analysed. During the follow-up, 369 patients remained in DDD mode stimulation. DDD mode survival rate at one, five, ten and 15 years was, respectively, 96%, 86%, 77% and 72%. The most common reason for reprogramming out of DDD mode was the development of permanent AF in 65 (13.1%) patients. The occurrence of chronic AF was associated with a prior history of paroxysmal AF (p = 0.0001), SSS (p = 0.0215), and older age at time of implantation (p = 0.0068) compared to patients who remained in sinus rhythm. Lead malfunction caused loss of DDD mode pacing in 56 (11.3%) patients. Atrial leads were damaged in 37 patients, ventricular in 12 patients, and both leads in seven patients. The subclavian vein puncture was correlated with the mechanical damage of the atrial lead (p = 0.02935) compared to cephalic vein access. At the moment of complication, the patients with a dysfunctional lead were significantly younger than those who progressed to chronic AF(p = 0.0019). Infective complications which caused temporary loss of DDD pacing were observed in six patients: five had pocket infection and one had lead-dependent infective endocarditis. 1. Effective DDD pacing from the originally implanted system was noted in a high percentage (72%) of patients in long-term observation (15 years

  15. Obstruction of adaptation in diploids by recessive, strongly deleterious alleles.

    PubMed

    Assaf, Zoe June; Petrov, Dmitri A; Blundell, Jamie R

    2015-05-19

    Recessive deleterious mutations are common, causing many genetic disorders in humans and producing inbreeding depression in the majority of sexually reproducing diploids. The abundance of recessive deleterious mutations in natural populations suggests they are likely to be present on a chromosome when a new adaptive mutation occurs, yet the dynamics of recessive deleterious hitchhikers and their impact on adaptation remains poorly understood. Here we model how a recessive deleterious mutation impacts the fate of a genetically linked dominant beneficial mutation. The frequency trajectory of the adaptive mutation in this case is dramatically altered and results in what we have termed a "staggered sweep." It is named for its three-phased trajectory: (i) Initially, the two linked mutations have a selective advantage while rare and will increase in frequency together, then (ii), at higher frequencies, the recessive hitchhiker is exposed to selection and can cause a balanced state via heterozygote advantage (the staggered phase), and (iii) finally, if recombination unlinks the two mutations, then the beneficial mutation can complete the sweep to fixation. Using both analytics and simulations, we show that strongly deleterious recessive mutations can substantially decrease the probability of fixation for nearby beneficial mutations, thus creating zones in the genome where adaptation is suppressed. These mutations can also significantly prolong the number of generations a beneficial mutation takes to sweep to fixation, and cause the genomic signature of selection to resemble that of soft or partial sweeps. We show that recessive deleterious variation could impact adaptation in humans and Drosophila.

  16. Methylphenidate and environmental enrichment ameliorate the deleterious effects of prenatal stress on attention functioning.

    PubMed

    Zubedat, Salman; Aga-Mizrachi, Shlomit; Cymerblit-Sabba, Adi; Ritter, Ami; Nachmani, Maayan; Avital, Avi

    2015-01-01

    Either pre- or post-natal environmental factors seem to play a key role in brain and behavioral development and to exert long-term effects. Increasing evidence suggests that exposure to prenatal stress (PS) leads to motor and learning deficits and elevated anxiety, while enriched environment (EE) shows protective effects. The dopaminergic system is also sensitive to environmental life circumstances and affects attention functioning, which serves as the preliminary gate to cognitive processes. However, the effects of methylphenidate (MPH) on the dopaminergic system and attentional functioning, in the context of these life experiences, remain unclear. Therefore, we aimed to examine the effects of EE or PS on distinct types of attention, along with possible effects of MPH exposure. We found that PS impaired selective attention as well as partial sustained attention, while EE had beneficial effects. Both EE and MPH ameliorated the deleterious effects of PS on attention functioning. Considering the possible psychostimulant effect of MPH, we examined both anxiety-like behavior as well as motor learning. We found that PS had a clear anxiogenic effect, whereas EE had an anxiolytic effect. Nevertheless, the treatment with both MPH and/or EE recovered the deleterious effects of PS. In the motor-learning task, the PS group showed superior performance while MPH led to impaired motor learning. Performance decrements were prevented in both the PS + MPH and EE + MPH groups. This study provides evidence that peripubertal exposure to EE (by providing enhanced sensory, motor, and social opportunities) or MPH treatments might be an optional therapeutic intervention in preventing the PS long-term adverse consequences.

  17. Long-term fuel retention in JET ITER-like wall

    NASA Astrophysics Data System (ADS)

    Heinola, K.; Widdowson, A.; Likonen, J.; Alves, E.; Baron-Wiechec, A.; Barradas, N.; Brezinsek, S.; Catarino, N.; Coad, P.; Koivuranta, S.; Krat, S.; Matthews, G. F.; Mayer, M.; Petersson, P.; Contributors, JET

    2016-02-01

    Post-mortem studies with ion beam analysis, thermal desorption, and secondary ion mass spectrometry have been applied for investigating the long-term fuel retention in the JET ITER-like wall components. The retention takes place via implantation and co-deposition, and the highest retention values were found to correlate with the thickness of the deposited impurity layers. From the total amount of retained D fuel over half was detected in the divertor region. The majority of the retained D is on the top surface of the inner divertor, whereas the least retention was measured in the main chamber on the mid-plane of the inner wall limiter. The recessed areas of the inner wall showed significant contribution to the main chamber total retention. Thermal desorption spectroscopy analysis revealed the energetic T from DD reactions being implanted in the divertor. The total T inventory was assessed to be \\gt 0.3 {{mg}}.

  18. "Long-term stability of stimulating spiral nerve cuff electrodes on human peripheral nerves".

    PubMed

    Christie, Breanne P; Freeberg, Max; Memberg, William D; Pinault, Gilles J C; Hoyen, Harry A; Tyler, Dustin J; Triolo, Ronald J

    2017-07-11

    Electrical stimulation of the peripheral nerves has been shown to be effective in restoring sensory and motor functions in the lower and upper extremities. This neural stimulation can be applied via non-penetrating spiral nerve cuff electrodes, though minimal information has been published regarding their long-term performance for multiple years after implantation. Since 2005, 14 human volunteers with cervical or thoracic spinal cord injuries, or upper limb amputation, were chronically implanted with a total of 50 spiral nerve cuff electrodes on 10 different nerves (mean time post-implant 6.7 ± 3.1 years). The primary outcome measures utilized in this study were muscle recruitment curves, charge thresholds, and percent overlap of recruited motor unit populations. In the eight recipients still actively involved in research studies, 44/45 of the spiral contacts were still functional. In four participants regularly studied over the course of 1 month to 10.4 years, the charge thresholds of the majority of individual contacts remained stable over time. The four participants with spiral cuffs on their femoral nerves were all able to generate sufficient moment to keep the knees locked during standing after 2-4.5 years. The dorsiflexion moment produced by all four fibular nerve cuffs in the active participants exceeded the value required to prevent foot drop, but no tibial nerve cuffs were able to meet the plantarflexion moment that occurs during push-off at a normal walking speed. The selectivity of two multi-contact spiral cuffs was examined and both were still highly selective for different motor unit populations for up to 6.3 years after implantation. The spiral nerve cuffs examined remain functional in motor and sensory neuroprostheses for 2-11 years after implantation. They exhibit stable charge thresholds, clinically relevant recruitment properties, and functional muscle selectivity. Non-penetrating spiral nerve cuff electrodes appear to be a suitable option

  19. Do sedation and analgesia contribute to long-term cognitive dysfunction in critical care survivors?

    PubMed

    Fernandez-Gonzalo, S; Turon, M; De Haro, C; López-Aguilar, J; Jodar, M; Blanch, L

    2018-03-01

    Deep sedation during stay in the Intensive Care Unit (ICU) may have deleterious effects upon the clinical and cognitive outcomes of critically ill patients undergoing mechanical ventilation. Over the last decade a vast body of literature has been generated regarding different sedation strategies, with the aim of reducing the levels of sedation in critically ill patients. There has also been a growing interest in acute brain dysfunction, or delirium, in the ICU. However, the effect of sedation during ICU stay upon long-term cognitive deficits in ICU survivors remains unclear. Strategies for reducing sedation levels in the ICU do not seem to be associated with worse cognitive and psychological status among ICU survivors. Sedation strategy and management efforts therefore should seek to secure the best possible state in the mechanically ventilated patient and lower the prevalence of delirium, in order to prevent long-term cognitive alterations. Copyright © 2017 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  20. Clinical and Radiographic Evaluation of Brånemark Implants with an Anodized Surface following Seven-to-Eight Years of Functional Loading

    PubMed Central

    Gelb, David; McAllister, Bradley; Nummikoski, Pirkka; Del Fabbro, Massimo

    2013-01-01

    The aim of this study was to evaluate the clinical and radiographic long-term outcomes of dental implants with an anodized TiUnite surface, placed in routine clinical practice. Two clinical centers participated in the study. One hundred and seven implants (80 in the maxilla and 27 in the mandible) in 52 patients were followed in the long term. Both one- and two-stage techniques were used for 38 and 69 implants, respectively. Thirty-eight single tooth restorations and 22 fixed partial prostheses were delivered, according to a delayed loading protocol, within 4 to 12 months since implant placement. All implants were stable at insertion and at the long-term follow-up visit, which occurred between 7 and 8 years of functional loading. The mean followup was 7.33 ± 0.47 years. The mean marginal bone level change at the long-term followup as compared to baseline was 1.49 ± 1.03 mm. No implant failure occurred. Healthy peri-implant mucosa was found around 95% of implants, whereas 91% of implants showed no visible plaque at the implant surfaces at the long-term followup. The study showed that dental implants with the TiUnite anodized surface demonstrate excellent long-term clinical and radiographic outcomes. PMID:23533412

  1. Accessibility of long-term family planning methods: a comparison study between Output Based Approach (OBA) clients verses non-OBA clients in the voucher supported facilities in Kenya.

    PubMed

    Oyugi, Boniface; Kioko, Urbanus; Kaboro, Stephen Mbugua; Gikonyo, Shadrack; Okumu, Clarice; Ogola-Munene, Sarah; Kalsi, Shaminder; Thiani, Simon; Korir, Julius; Odundo, Paul; Baltazaar, Billy; Ranji, Moses; Muraguri, Nicholas; Nzioka, Charles

    2017-03-27

    The study seeks to evaluate the difference in access of long-term family planning (LTFP) methods among the output based approach (OBA) and non-OBA clients within the OBA facility. The study utilises a quasi experimental design. A two tailed unpaired t-test with unequal variance is used to test for the significance variation in the mean access. The difference in difference (DiD) estimates of program effect on long term family planning methods is done to estimate the causal effect by exploiting the group level difference on two or more dimensions. The study also uses a linear regression model to evaluate the predictors of choice of long-term family planning methods. Data was analysed using SPSS version 17. All the methods (Bilateral tubal ligation-BTL, Vasectomy, intrauterine contraceptive device -IUCD, Implants, and Total or combined long-term family planning methods -LTFP) showed a statistical significant difference in the mean utilization between OBA versus non-OBA clients. The difference in difference estimates reveal that the difference in access between OBA and non OBA clients can significantly be attributed to the implementation of the OBA program for intrauterine contraceptive device (p = 0.002), Implants (p = 0.004), and total or combined long-term family planning methods (p = 0.001). The county of residence is a significant determinant of access to all long-term family planning methods except vasectomy and the year of registration is a significant determinant of access especially for implants and total or combined long-term family planning methods. The management level and facility type does not play a role in determining the type of long-term family planning method preferred; however, non-governmental organisations (NGOs) as management level influences the choice of all methods (Bilateral tubal ligation, intrauterine contraceptive device, Implants, and combined methods) except vasectomy. The adjusted R 2 value, representing the percentage of

  2. Emerging technologies for long-term antimicrobial device coatings: advantages and limitations

    PubMed Central

    Cyphert, Erika L

    2017-01-01

    Over the past 20 years, the field of antimicrobial medical device coatings has expanded nearly 30-fold with technologies shifting their focus from diffusion-only based (short-term antimicrobial eluting) coatings to long-term antimicrobial eluting and intrinsically antimicrobial functioning materials. A variety of emergent coatings have been developed with the goal of achieving long-term antimicrobial activity in order to mitigate the risk of implanted device failure. Specifically, the coatings can be grouped into two categories: those that use antibiotics in conjunction with a polymer coating and those that rely on the intrinsic properties of the material to kill or repel bacteria that come into contact with the surface. This review covers both long-term drug-eluting and non-eluting coatings and evaluates the inherent advantages and disadvantages of each type while providing an overview of variety applications that the coatings have been utilized in. Impact statement This work provides an overview, with advantages and limitations of the most recently developed antibacterial coating technologies, enabling other researchers in the field to more easily determine which technology is most advantageous for them to further develop and pursue. PMID:28110543

  3. Long-term in vivo corrosion behavior, biocompatibility and bioresorption mechanism of a bioresorbable nitrided iron scaffold.

    PubMed

    Lin, Wenjiao; Qin, Li; Qi, Haiping; Zhang, Deyuan; Zhang, Gui; Gao, Runlin; Qiu, Hong; Xia, Ying; Cao, Ping; Wang, Xiang; Zheng, Wei

    2017-05-01

    Pure iron as a potential bioresorbable material for bioresorbable coronary scaffold has major disadvantages of slow corrosion and bioresorption. However, so far, there are neither quantitative data of long-term in vivo corrosion nor direct experimental evidence for bioresorption of pure iron and its alloys, which are fundamental and vital for developing novel Fe-based alloys overcoming the intrinsic drawbacks of pure iron. This work systemically investigated scaffold performance, long-term in vivo corrosion behavior and biocompatibility of a nitrided iron coronary scaffold and explored its bioresorption mechanism. It was found that the 70μm Fe-based scaffold was superior to a state of the art Co-Cr alloy stent (Xience Prime™) in terms of crossing profile, recoil and radial strength. Mass loss was 76.0±8.5wt% for the nitrided iron scaffold and 44.2±11.4wt% for the pure iron scaffold after 36months implantation in rabbit abdominal aorta (p<0.05). The Fe-based scaffold showed good long-term biocompatibility in both rabbit and porcine model. Its insoluble corrosion products were demonstrated biosafe and could be cleared away by macrophages from in situ to adventitia to be indiscernible by Micro Computed Tomography and probably finally enter the lymphatics and travel to lymph nodes after 53months implantion in porcine coronary artery. The results indicate that the nitrided iron scaffold with further improvements shall be promising for coronary application. Pure iron as a potential bioresorbable material has major disadvantages of slow corrosion and bioresorption. However, so far, there are neither quantitative data of long-term in vivo corrosion nor direct experimental evidence for bioresorption of pure iron and its alloys. Only this work systemically investigated long-term in vivo corrosion behavior and biocompatibility of a nitrided iron coronary scaffold up to 53months after implantation and explored its bioresorption mechanism. These are fundamental and vital

  4. Long-term single-center experience of defibrillator therapy in children and adolescents.

    PubMed

    Frommeyer, Gerrit; Feder, Sebastian; Bettin, Markus; Debus, Volker; Köbe, Julia; Reinke, Florian; Uebing, Anselm; Eckardt, Lars; Kehl, Hans Gerd

    2018-06-01

    Implantable cardioverter-defibrillator (ICD) systems are established therapy for prevention of sudden cardiac death. Long-term data on ICD systems in children and adolescents is rare. The present study displays a long-term single-center follow-up of children and adolescents with ICD systems. The present study represents a single-center experience of patients younger than 18 years who received an ICD (n = 58). Follow-up data included in-house follow-up as well as examinations of collaborating specialists. Mean age at implantation was 14.0 ± 3.3 years and 33 patients (56.9%) were male. A transvenous ICD system was implanted in 54 patients (93.1%). In 33 patients (56.9%) electrical heart disease or idiopathic ventricular fibrillation represented the underlying condition of ICD implantation. Median follow-up duration was 70 months (45; 94). 3 patients (5.2%) died during the observation period. None of these deaths was associated with ICD failure. Appropriate shocks occurred in 32 patients (55.2%). Inappropriate shock delivery was recorded in 17 patients (29.3%). Supraventricular tachycardia represented the most frequent cause of inappropriate shock delivery (9 patients, 52.9%). T-wave oversensing led to inappropriate shock delivery in 3 patients (17.6%). In 5 patients (29.4%), lead failure caused inappropriate shock delivery. Of note, during follow-up lead failure was reported in 15 patients (25.9%) leading to surgical revision. ICD therapy in children and adolescents is effective for prevention of sudden cardiac death. The rate of appropriate shock deliveries was significantly higher as compared with large ICD trials. Inappropriate therapies occurred frequently. In particular supraventricular tachycardia, T-wave oversensing and lead failures were responsible for these episodes. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. A residual granuloma in association with a dental implant.

    PubMed

    McCracken, Michael S; Chavali, Ramakiran V; Al-Naief, Nasser Said; Eleazer, Paul D

    2012-04-01

    At times, dental implants are placed into sites with a history of periapical pathology. Sometimes the infection is active, and other times the tooth may have been extracted years before implant placement. In either case, the possibility exists for long-term residual cysts or infections that can negatively impact the prognosis of the implant. In this case report, an implant is placed into a healed mandibular ridge several months after extraction of the tooth. A radiolucency was noted on routine radiographic examination 2 years later. Surgical inspection and histology revealed a periapical granuloma with acute and chronic inflammatory cells. After surgical curettage of the site, the patient healed without complication. Implants may develop apical pathology as a result of a preexisting long-term residual infection.

  6. Concurrent electrophysiology and TPM/OCT imaging of long-term implanted electrodes (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Hammer, Daniel X.; Gao, Yu-Rong; Ye, Meijun; Welle, Cristin G.

    2017-02-01

    Microelectrodes implanted in the brain cause mechanical damage to the tissue that mediate neuroinflammation and eventual encapsulation by microglia and astrocytes. Electrophysiological signals recorded from implants used in brain-computer interfaces (BCI) degrade over time, limiting their usefulness, but the precise causes and progression are not fully understood. We are investigating the dynamics of brain morphological changes and neuroinflammation with a multimodal approach to better understand the potential causes of implant failure. We performed weekly optical coherence tomography (OCT)-guided two-photon microscopy (TPM) in the region around microelectrodes inserted under a cranial window concurrent with electrophysiological recordings. Transgenic mouse cohorts studied include Thy1-YFP, Cx3cr1, and GFAP-GFP to image neurons, microglia, and astrocytes, respectively. Single-shank, 16-channel, Michigan-style microelectrodes were inserted under the window at a 15-20° angle with an insertion depth up to cortical layer 5. Single-unit and local field potential (LFP) recordings were collected for 15 minutes while the animals moved freely in their home cages. Cellular and vascular morphology were monitored using TPM and OCT at timepoints matched to the recordings. In preliminary data, we observed a decay of neural firing rates in most of the channels after implantation. The relationship between electrophysiological measures (e.g., neural firing rate, LFP power) and neural/vascular morphological measurements (e.g., cell density, glial migration, blood flow changes) will be quantified. The multimodal approach combining electrophysiology and optical imaging provides a broader picture of the multifactorial nature of the response to implanted electrodes. Understanding and accounting for the response may lead to better BCI designs and approaches.

  7. [An ultra-low power, wearable, long-term ECG monitoring system with mass storage].

    PubMed

    Liu, Na; Chen, Yingmin; Zhang, Wenzan; Luo, Zhangyuan; Jin, Xun; Ying, Weihai

    2012-01-01

    In this paper, we described an ultra-low power, wearable ECG system capable of long term monitoring and mass storage. This system is based on micro-chip PIC18F27J13 with consideration of its high level of integration and low power consumption. The communication with the micro-SD card is achieved through SPI bus. Through the USB, it can be connected to the computer for replay and disease diagnosis. Given its low power cost, lithium cells are used to support continuous ECG acquiring and storage for up to 15 days. Meanwhile, the wearable electrodes avoid the pains and possible risks in implanting. Besides, the mini size of the system makes long wearing possible for patients and meets the needs of long-term dynamic monitoring and mass storage requirements.

  8. New-Onset Left Bundle Branch Block Induced by Transcutaneous Aortic Valve Implantation.

    PubMed

    Massoullié, Grégoire; Bordachar, Pierre; Ellenbogen, Kenneth A; Souteyrand, Géraud; Jean, Frédéric; Combaret, Nicolas; Vorilhon, Charles; Clerfond, Guillaume; Farhat, Mehdi; Ritter, Philippe; Citron, Bernard; Lusson, Jean-R; Motreff, Pascal; Ploux, Sylvain; Eschalier, Romain

    2016-03-01

    New-onset left bundle branch block (LBBB) is a specific concern of transcutaneous aortic valve implantation (TAVI) given its estimated incidence ranging from 5% to 65%. This high rate of occurrence is dependent on the type of device used (size and shape), implantation methods, and patient co-morbidities. The appearance of an LBBB after TAVI reflects a very proximal lesion of the left bundle branch as it exits the bundle of His. At times transient, its persistence can lead to permanent pacemaker implantation in 15% to 20% of cases, most often for high-degree atrioventricular block. The management of LBBB after TAVI is currently not defined by international societies resulting in individual centers developing their own management strategy. The potential consequences of LBBB are dysrhythmias (atrioventricular block, syncope, and sudden death) and functional (heart failure) complications. Prompt postprocedural recognition and management (permanent pacemaker implantation) of patients prevents the occurrence of potential complications and may constitute the preferred approach in this frail and elderly population despite additional costs and complications of cardiac pacing. Moreover, the expansion of future indications for TAVI necessitates better identification of the predictive factors for the development of LBBB. Indeed, long-term right ventricular pacing may potentially increase the risk of developing heart failure in this population. In conclusion, it is thus imperative to not only develop new aortic prostheses with a less-deleterious impact on the conduction system but also to prescribe appropriate pacing modes in this frail population. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Decontamination of dental implant surface in peri-implantitis treatment: A literature review

    PubMed Central

    Buitrago-Vera, Pedro; Solá-Ruiz, María F.; Ferrer-García, Juan C.

    2013-01-01

    Etiological treatment of peri-implantitis aims to reduce the bacterial load within the peri-implant pocket and decontaminate the implant surface in order to promote osseointegration. The aim of this literature review was to evaluate the efficacy of different methods of implant surface decontamination. A search was conducted using the PubMed (Medline) database, which identified 36 articles including in vivo and in vitro studies, and reviews of different decontamination systems (chemical, mechanical, laser and photodynamic therapies). There is sufficient consensus that, for the treatment of peri-implant infections, the mechanical removal of biofilm from the implant surface should be supplemented by chemical decontamination with surgical access. However, more long-term research is needed to confirm this and to establish treatment protocols responding to different implant characterics. Key words:Peri-implantitis, treatment, decontamination, implant surface, laser. PMID:23986023

  10. Evaluation of the Etiologies of Implant Fracture in Patients With Fractures of the Implants of Lower Limbs’ Long Bones

    PubMed Central

    Yeganeh, Ali; Otoukesh, Babak; Kaghazian, Peyman; Yeganeh, Nima; Boddohi, Bahram; Moghtadaei, Mehdi

    2015-01-01

    Background: Orthopedics implants are important tools for treatment of bone fractures. Despite available recommendations for designing and making the implants, there are multiple cases of fracture of these implants in the body. Hence, in this study the frequency of failure of implants in long bones of lower extremities was evaluated. Methods and Materials: In this cross-sectional study, two types of fractured implants in the body were analyzed and underwent metalogical, mechanical, and modeling and stress-bending analysis. Results: The results revealed that the main cause of fractures was decreased mechanical resistance due to inappropriate chemical composition (especially decreased percentages of Nickel and Molybdenum). Conclusions: It may be concluded that following the standard chemical composition and use of optimal making method are the most important works for prevention of failure of implants. PMID:26843735

  11. Dual- versus single-coil implantable defibrillator leads: review of the literature.

    PubMed

    Neuzner, Jörg; Carlsson, Jörg

    2012-04-01

    The preferred use of dual-coil implantable defibrillator lead systems in current implantable defibrillator therapy is likely based on data showing statistically lower defibrillation thresholds with dual-coil defibrillator lead systems. The following review will summarize the clinical data for dual- versus single-coil defibrillator leads in the left and right pectoral implant locations, and will then discuss the clinical implications of single- versus dual-coil usage for atrial defibrillation, venous complications, and the risks associated with lead extraction. It will be noted that there are no comparative clinical studies on the use and outcomes of single- versus dual-coil lead systems in implantable defibrillator therapy over a long-term follow-up. The limited long-term reliability of defibrillator leads is a major concern in implantable defibrillator and cardiac resynchronization therapy. A simpler single-coil defibrillator lead system may improve the long-term performance of implanted leads. Furthermore, the superior vena cava coil is suspected to increase interventional risk in transvenous lead extraction. Therefore, the need for objective data on extractions and complications will be emphasized.

  12. Comparison of the long-term safety and efficacy of drug-eluting and bare-metal stent implantation in saphenous vein grafts.

    PubMed

    Latib, Azeem; Ferri, Luca; Ielasi, Alfonso; Cosgrave, John; Godino, Cosmo; Bonizzoni, Erminio; Romagnoli, Enrico; Chieffo, Alaide; Valgimigli, Marco; Penzo, Carlo; Carlino, Mauro; Michev, Iassen; Sangiorgi, Giuseppe M; Montorfano, Matteo; Airoldi, Flavio; Colombo, Antonio

    2010-06-01

    Concerns about the long-term safety of drug-eluting stents (DES) in saphenous vein grafts has become an area of controversy and uncertainty. In this retrospective registry, we compared the outcomes in 127 patients (143 lesions) treated with DES from April 2002 to June 2006 (DES group) with 131 patients (160 lesions) treated with bare-metal stents in the preceding 36 months (bare-metal stent group). End points analyzed were cumulative death, myocardial infarction, and target vessel revascularization at 2 years after stent implantation. The DES group was significantly (P<0.05) more complex with a greater frequency of diabetes (33.1%versus 15.3%), older grafts (11.6+/-5.3 years versus 9.6+/-5.2 years), restenotic lesions (23.8% versus 4.4%), total occlusions (7.7% versus 1.2%), and smaller grafts (3.16+/-0.66 mm versus 3.44+/-0.76 mm) treated with longer stents (34.1+/-25.1 mm versus 22.7+/-11.6 mm). At 2 years, there was no statistical difference in death (8.7% versus 7.8%), myocardial infarction (6.3% versus 9.4%), or target vessel revascularization (19.7% versus 24.2%) between DES and bare-metal stents, respectively. A propensity analysis to adjust for baseline differences suggested that there was no observed association between DES and increased mortality (hazard ratio, 0.72; 95% CI, 0.21 to 2.44; P=0.60) but possibly an association with a reduction in target vessel revascularization (hazard ratio, 0.31; 95% CI, 0.14 to 0.66; P=0.002). Despite being implanted in patients and lesions more complex than the bare-metal stent group, there was no observed association between DES implantation in saphenous vein grafts and an increase in late mortality. DES may maintain their efficacy in reducing revascularization rates in diseased saphenous vein grafts over a 2-year follow-up period.

  13. Short-term risk of falling after cochlear implantation.

    PubMed

    Stevens, Madelyn N; Baudhuin, Jacqueline E; Hullar, Timothy E

    2014-01-01

    Cochlear implantation is a highly effective intervention for hearing loss, but insertion of an implant into the cochlea is often accompanied by loss of residual hearing function. Sometimes, postoperative testing also shows loss of function in the semicircular canals or otolith organs. The effect of this loss on equilibrium, particularly in the short term following surgery, and the risk of falling due to this loss is unknown. We prospectively measured balance in 16 consecutive adult cochlear implant patients before and 2 weeks after surgery. Subjects stood on a foam pad with eyes closed, feet together and arms at the side. The length of time over which this posture could be maintained was recorded up to a maximum value of 30 s indicating normal performance. Ten of 16 subjects reached a maximal time on preoperative testing. Nine of 16 subjects lost balance function after surgery. Four of the 10 subjects with normal preoperative balance function lost function. Subjects older than the age of 60 were more likely to lose balance function than younger subjects. We used previously published values relating balance performance on foam to risk of falling to calculate the fall risk among our subjects. The relative risk of falling increased after surgery by more than threefold in some patients. Imbalance after cochlear implantation may be much more common, particularly in the short term, than previously appreciated. This imbalance is accompanied by an increased risk of falling in many patients. Careful preoperative counseling before implantation and postoperative therapeutic intervention to improve comfort and reduce the chance of falling may be warranted, particularly in patients at a risk for injuries from falls (level of evidence: 2b). © 2014 S. Karger AG, Basel.

  14. Long-term results with percutaneous interspinous process devices in the treatment of neurogenic intermittent claudication.

    PubMed

    Fransen, Patrick

    2017-12-01

    Neurogenic intermittent claudication (NIC) is the main symptom of degenerative lumbar spinal stenosis. Percutaneous interspinous process decompression devices (IPDs) have been designed as an alternative therapy to conservative treatment and to open decompressive surgery for patients suffering from NIC. Initial short-term results were encouraging. We present the long-term results of a group of patients that we followed to provide insight on long-term outcomes and effectiveness of this technique compared to other decompression methods. Fifteen patients operated for NIC by implantation of percutaneous IPDs have been prospectively monitored for reoperations or complications. Follow-up (FU) was interrupted if the patient was reoperated. Results were considered poor if the patient had to be reoperated at any stage of the FU or if the treatment failed to alleviate the pain after 6 months. Results were considered average if the patient still suffered some pain but did not require reoperation. The patients were followed up to 7 years after the initial surgery. The mean length of the FU was 3.53 years and all patients could be followed. At the end of the FU, the results were good in only 20.0% (3/15), average in 13.3% (2/15) and poor in 66.7% (10/15). Despite initial satisfactory results, long-term FU is disappointing, with 80% poor or average results. The long-term reoperation rate is high (66.6%), increases over time and is higher than after implantation of IPDs for decompression augmentation. Although this technique is simple and safe, its effectiveness seems short-lived. We recommend cautious use and informing patients about the risk of relatively early failure and recurrence.

  15. Cancer among Scandinavian women with cosmetic breast implants: a pooled long-term follow-up study.

    PubMed

    Lipworth, Loren; Tarone, Robert E; Friis, Søren; Ye, Weimin; Olsen, Jørgen H; Nyren, Olof; McLaughlin, Joseph K

    2009-01-15

    No increased risks of specific types of cancer following breast implantation have been consistently reported, but data on risk beyond 15 years are limited. We have pooled the results of 2 nationwide cohort studies of 3,486 Swedish and 2,736 Danish women who underwent cosmetic breast implantation between 1965 and 1993. Cancer incidence through 2002 was ascertained through nationwide cancer registries. Standardized incidence ratios (SIRs) and 95% confidence intervals (CIs) were calculated to compare cancer incidence among women with implants with women in the general population. Mean duration of follow up was 16.6 years (range 0.1-37.8 years). Over 50% of women were followed for 15 years or more after breast implantation and 13.3% for at least 25 years. There was a reduced incidence of breast cancer (SIR=0.73; 95% CI 0.58-0.90), whereas lung cancer was above expectation (SIR=1.64; 95% CI 1.10-2.36). The increased risk of lung cancer is expected due to the high prevalence of smoking among the women with implants in our study. With respect to other site-specific cancers, no significantly increased or decreased SIR was observed. This study, which includes women followed for almost 4 decades, represents the longest follow up of women with cosmetic breast implants to date. The results provide no evidence of an association between breast implants and any type of cancer. Copyright (c) 2008 Wiley-Liss, Inc.

  16. Toward Patient Specific Long Lasting Metallic Implants for Mandibular Segmental Defects

    NASA Astrophysics Data System (ADS)

    Shayesteh Moghaddam, Narges

    Mandibular defects may result from tumor resection, trauma, or inflammation. The goals of mandibular reconstruction surgeries are to restore mandible function and aesthetics. To this end, surgeons use a combination of bone grafts and metallic implants. These implants have drastically different mechanical properties than the surrounding bone. As a result, the stress distribution in the mandible changes after surgery. The long-term abnormal stress/strain distribution may lead to either graft failure due to bone resorption as a result of stress shielding, or hardware failure due to stress concentrations. During the healing period of six to nine months it is important that complete immobilization, bringing mandibular micro-motion down to the level of 200-500 mum during chewing, is achieved. After this period it is desired that bone undergo normal stress for long-term success of the treatment. Although current high stiffness fixation hardware accomplishes this immobilization during the healing period, the hardware continues to alter the normal stress-strain trajectory seen during chewing once the engrafted bone heals. Over the long-term, the immobilized and stress-shielded engrafted bone tends to resorb. On the other hand, hardware fracturing or/and screw loosening is observed as the stress is concentrated at certain locations on the hardware. Equally as important is the permanent loss of chewing power due to the altered stress-strain relationships. The first stage of this research is to study the problems encountered following a mandibular segmental defect reconstructive surgery. To this end, we constructed a finite element model of a healthy mandible, which includes cortical and cancellous bone, teeth (enamel and dentin components), and the periodontal ligament. Using this model, we studied a healthy adult mandible under maximum molar bite force for stress, strain, displacement, and reaction force distribution. For mandibular segmental defect reconstruction the

  17. Long-term remote organ consequences following acute kidney injury.

    PubMed

    Shiao, Chih-Chung; Wu, Pei-Chen; Huang, Tao-Min; Lai, Tai-Shuan; Yang, Wei-Shun; Wu, Che-Hsiung; Lai, Chun-Fu; Wu, Vin-Cent; Chu, Tzong-Shinn; Wu, Kwan-Dun

    2015-12-28

    Acute kidney injury (AKI) has been a global health epidemic problem with soaring incidence, increased long-term risks for multiple comorbidities and mortality, as well as elevated medical costs. Despite the improvement of patient outcomes following the advancements in preventive and therapeutic strategies, the mortality rates among critically ill patients with AKI remain as high as 40-60 %. The distant organ injury, a direct consequence of deleterious systemic effects, following AKI is an important explanation for this phenomenon. To date, most evidence of remote organ injury in AKI is obtained from animal models. Whereas the observations in humans are from a limited number of participants in a relatively short follow-up period, or just focusing on the cytokine levels rather than clinical solid outcomes. The remote organ injury is caused with four underlying mechanisms: (1) "classical" pattern of acute uremic state; (2) inflammatory nature of the injured kidneys; (3) modulating effect of AKI of the underlying disease process; and (4) healthcare dilemma. While cytokines/chemokines, leukocyte extravasation, oxidative stress, and certain channel dysregulation are the pathways involving in the remote organ damage. In the current review, we summarized the data from experimental studies to clinical outcome studies in the field of organ crosstalk following AKI. Further, the long-term consequences of distant organ-system, including liver, heart, brain, lung, gut, bone, immune system, and malignancy following AKI with temporary dialysis were reviewed and discussed.

  18. Long-term results of sacral neuromodulation for women with urinary retention.

    PubMed

    Dasgupta, Ranan; Wiseman, Oliver J; Kitchen, Neil; Fowler, Clare J

    2004-08-01

    OBJECTIVE ; To review the long-term results of sacral nerve stimulation in the treatment of women with Fowler's syndrome, over a 6-year period at one tertiary referral centre. Between 1996 and 2002, 26 women with urinary retention were treated by implanting a sacral nerve stimulator. Their case records were reviewed for follow-up, complications and revision procedures, and the most recent uroflowmetry results. There were 20 patients (77%) still voiding spontaneously at the time of review (with two having deactivated their stimulator because of pregnancy). Fourteen patients (54%) required revision surgery, and the most common complications included loss of efficacy, implant-related discomfort and leg pain. The mean postvoid residual volume was 75 mL and mean maximum flow rate 20.8 mL/s. In young women with retention, for whom there is still no alternative to lifelong self-catheterization, sacral neuromodulation is effective for up to 5 years after implantation. However, there was a significant complication rate, in line with other reports, which may be improved by new technical developments.

  19. The long-term in vivo behavior of polymethyl methacrylate bone cement in total hip arthroplasty.

    PubMed

    Oonishi, Hiroyuki; Akiyama, Haruhiko; Takemoto, Mitsuru; Kawai, Toshiyuki; Yamamoto, Koji; Yamamuro, Takao; Oonishi, Hironobu; Nakamura, Takashi

    2011-10-01

    The long-term success of cemented total hip arthroplasty (THA) has been well established. Improved outcomes, both radiographically and clinically, have resulted mainly from advances in stem design and improvements in operating techniques. However, there is concern about the durability of bone cement in vivo. We evaluated the physical and chemical properties of CMW1 bone cements retrieved from patients undergoing revision THA. CMW1 cements were retrieved from 14 patients who underwent acetabular revision because of aseptic loosening. The time in vivo before revision was 7-30 years. The bending properties of the retrieved bone cement were assessed using the three-point bending method. The molecular weight and chemical structure were analyzed by gel permeation chromatography and Fourier-transform infrared spectroscopy. The porosity of the bone cements was evaluated by 3-D microcomputer tomography. The bending strength decreased with increasing time in vivo and depended on the density of the bone cement, which we assume to be determined by the porosity. There was no correlation between molecular weight and time in vivo. The infrared spectra were similar in the retrieved cements and in the control CMW1 cements. Our results indicate that polymer chain scission and significant hydrolysis do not occur in CMW1 cement after implantation in vivo, even in the long term. CMW1 cement was stable through long-term implantation and functional loading.

  20. Quality of vision, patient satisfaction and long-term visual function after bilateral implantation of a low addition multifocal intraocular lens.

    PubMed

    Pedrotti, Emilio; Mastropasqua, Rodolfo; Bonetto, Jacopo; Demasi, Christian; Aiello, Francesco; Nucci, Carlo; Mariotti, Cesare; Marchini, Giorgio

    2017-07-17

    The aim of the current study was to compare the quality of vision, contrast sensitivity and patient satisfaction with a biaspheric, segmented, rotationally asymmetric IOL (Lentis Comfort LS-313 MF 15-Oculentis GmbH, Berlin, Germany) as opposed to those of a monofocal IOL. This prospective single-blind comparative study included two groups of patients affected by bilateral senile cataract who underwent lens extraction and IOL implantation. The first group received a bilateral implantation of a monofocal IOL, and the second group received a bilateral implantation of the Comfort IOL. Twelve months after surgery uncorrected and corrected visual acuity at different distances (30, 50, 70 cm and 4 m), defocus curve and contrast sensitivity were assessed. Patient's satisfaction and spectacle independence were evaluated by mean of the NEI RQL-42 questionnaire. No significant differences were found between the groups in terms of near vision. The group of patients implanted with a Comfort IOL obtained the best results at intermediate distances (50 and 70 cm P < .001). Both groups showed an excellent uncorrected distance visual acuity (4 m). No statistically significant differences were found in terms of corrected near, intermediate and distance visual acuity. Concerning contrast sensitivity, no statistically significant differences between the groups were observed at any cycles per degree. The NEI RQL-42 questionnaire showed statistically significant differences between the group for "near vision" (P = .015), "dependence on correction" (P = .048) and "suboptimal correction" (P < .001) subscales. Our findings indicated that the Comfort IOL +1.5 D provides a good intermediate spectacle independence together with a high quality of vision, with a low amount of subjective symptoms and a contrast sensitivity similar to those obtained with a monofocal IOL.

  1. Long-Term Observation of Triplex Surgery for Cataract after Phakic 6H Implantation for Super High Myopia

    PubMed Central

    Liu, Xin; Wang, Xiaoying; Lu, Yi; Zheng, Tianyu; Zhou, Xingtao

    2016-01-01

    Purpose. To analyze the safety, effectiveness, and stability of triplex surgery for phakic 6H anterior chamber phakic intraocular lens explantation and phacoemulsification with in-the-bag IOL implantation for super high myopia in long-term observations. Methods. This retrospective case series evaluated 16 eyes of 10 patients who underwent triplex surgery. Best corrected visual acuity (BCVA), endothelial cell density (ECD), and associated adverse events were evaluated. Results. The mean follow-up time after the triplex surgery was 46 ± 14 months. The mean logMAR BCVA was significantly improved after triplex surgery (P = 0.047). One eye developed endophthalmitis five days postoperatively and underwent pars plana vitrectomy (PPV). Five eyes with preoperative severe endothelial cell loss developed corneal decompensation and underwent keratoplasty at a mean time of 9.4 ± 2.6 months after the triplex surgery. One eye had graft failure and underwent a second keratoplasty. The eye developed rhegmatogenous retinal detachment and underwent PPV with silicone oil 18 months later. ECD before the triplex surgery was not significantly different compared with that at last follow-up (P = 0.495) apart from these five eyes. Three eyes (18.8%) developed posterior capsule opacification. Conclusions. Triplex surgery was safe and effective for phakic 6H related complicated cataracts. Early extraction before severe ECD loss is recommended. PMID:27190642

  2. Association of Short-term Bleeding and Cramping Patterns with Long-Acting Reversible Contraceptive Method Satisfaction

    PubMed Central

    Diedrich, Justin T.; Desai, Sanyukta; Zhao, Qiuhong; Secura, Gina; Madden, Tessa; Peipert, Jeffrey F.

    2014-01-01

    Objectives To examine the short-term (3 and 6-month), self-reported bleeding and cramping patterns with intrauterine devices (IUDs) and the contraceptive implant, and the association of these symptoms with method satisfaction. Study Design We analyzed 3 and 6-month survey data from IUD and implant users in the Contraceptive CHOICE Project, a prospective cohort study. Participants who received a long-acting reversible contraceptive (LARC) method (levonorgestrel intrauterine system (LNG-IUS), copper IUD, or the etonogestrel implant) and completed their 3- and 6-month surveys were included. Univariable and multivariable analyses were performed to examine the association of bleeding and cramping patterns with short-term satisfaction. Results Our analytic sample included 5,011 CHOICE participants: 3001 LNG-IUS users, 826 copper IUD users, and 1184 implant users. At 3 months, over 65% of LNG-IUS and implant users reported no change or decreased cramping, while 63% of copper IUD users reported increased menstrual cramping. Lighter bleeding was reported by 67% of LNG-IUS users, 58% of implant users, and 8% of copper IUD users. Satisfaction of all LARC methods was high (≥90%) and significantly higher than non-LARC methods (p<0.001). LARC users with increased menstrual cramping (HR 0.96, 95% CI 0.92 – 0.99), heavier bleeding (HR 0.91, 95% CI 0.87 – 0.96), and increased bleeding frequency (HR 0.92, 95% CI 0.89 – 0.96) were less likely to report being very satisfied at 6 months. Conclusion Regardless of the LARC method, satisfaction at 3 and 6 months is very high. Changes in self-reported bleeding and cramping are associated with short-term LARC satisfaction. PMID:25046805

  3. Association of short-term bleeding and cramping patterns with long-acting reversible contraceptive method satisfaction.

    PubMed

    Diedrich, Justin T; Desai, Sanyukta; Zhao, Qiuhong; Secura, Gina; Madden, Tessa; Peipert, Jeffrey F

    2015-01-01

    We sought to examine the short-term (3- and 6-month), self-reported bleeding and cramping patterns with intrauterine devices (IUDs) and the contraceptive implant, and the association of these symptoms with method satisfaction. We analyzed 3- and 6-month survey data from IUD and implant users in the Contraceptive CHOICE Project, a prospective cohort study. Participants who received a long-acting reversible contraceptive (LARC) method (levonorgestrel-releasing intrauterine system [LNG-IUS], copper IUD, or the etonogestrel implant) and completed their 3- and 6-month surveys were included. Univariable and multivariable analyses were performed to examine the association of bleeding and cramping patterns with short-term satisfaction. Our analytic sample included 5011 Contraceptive CHOICE Project participants: 3001 LNG-IUS users, 826 copper IUD users, and 1184 implant users. At 3 months, >65% of LNG-IUS and implant users reported no change or decreased cramping, while 63% of copper IUD users reported increased menstrual cramping. Lighter bleeding was reported by 67% of LNG-IUS users, 58% of implant users, and 8% of copper IUD users. Satisfaction of all LARC methods was high (≥90%). LARC users with increased menstrual cramping (relative risk adjusted [RRadj], 0.78; 95% confidence interval [CI], 0.72-0.85), heavier bleeding (RRadj, 0.83; 95% CI, 0.76-0.92), and increased bleeding frequency (RRadj, 0.73; 95% CI, 0.67-0.80) were less likely to report being very satisfied at 6 months. Regardless of the LARC method, satisfaction at 3 and 6 months is very high. Changes in self-reported bleeding and cramping are associated with short-term LARC satisfaction. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Detection of occult paroxysmal atrial fibrilation by implantable long-term electrocardiographic monitoring in cryptogenic stroke and transient ischemic attack population: a study protocol for prospective matched cohort study.

    PubMed

    Petrovičová, Andrea; Kurča, Egon; Brozman, Miroslav; Hasilla, Jozef; Vahala, Pavel; Blaško, Peter; Andrášová, Andrea; Hatala, Robert; Urban, Luboš; Sivák, Štefan

    2015-12-03

    Cardio-embolic etiology is the most frequently predicted cause of cryptogenic stroke/TIA. Detection of occult paroxysmal atrial fibrillation is crucial for selection of appropriate medication. Enrolment of eligible cryptogenic stroke and TIA patients began in 2014 and will continue until 2018. The patients undergo long-term (12 months) ECG monitoring (implantable loop recorder) and testing for PITX2 (chromosome 4q25) and ZFHX3 (chromosome 16q22) gene mutations. There will be an appropriate control group of age- and sex-matched healthy volunteers. To analyse the results descriptive statistics, statistical tests for group differences, and correlation analyses will be used. In our study we are focusing on a possible correlation between detection of atrial fibrillation by an implantable ECG recorder, and PITX2 and/or ZFHX3 gene mutations in cryptogenic stroke/TIA patients. A correlation could lead to implementation of this genomic approach to cryptogenic stroke/TIA diagnostics and management. The results will be published in 2018. ClinicalTrials.gov: NCT02216370 .

  5. Fixed Full Arches Supported by Tapered Implants with Knife-Edge Thread Design and Nanostructured, Calcium-Incorporated Surface: A Short-Term Prospective Clinical Study

    PubMed Central

    Bechara, Soheil; Lukosiunas, Algirdas; Kubilius, Ricardas

    2017-01-01

    Purpose. To evaluate implant survival, peri-implant bone loss, and complications affecting fixed full-arch (FFA) restorations supported by implants with a knife-edge thread design and nanostructured, calcium-incorporated surface. Methods. Between January 2013 and December 2015, all patients referred for implant-supported FFA restorations were considered for enrollment in this study. All patients received implants with a knife-edge thread design and nanostructured calcium-incorporated surface (Anyridge®, Megagen, South Korea) were restored with FFA restorations and enrolled in a recall program. The final outcomes were implant survival, peri-implant bone loss, biologic/prosthetic complications, and “complication-free” survival of restorations. Results. Twenty-four patients were selected. Overall, 215 implants were inserted (130 maxilla, 85 mandible), 144 in extraction sockets and 71 in healed ridges. Thirty-six FFAs were delivered (21 maxilla, 15 mandible): 27 were immediately loaded and 9 were conventionally loaded. The follow-up ranged from 1 to 3 years. Two fixtures failed, yielding an implant survival rate of 95.9% (patient-based). A few complications were registered, for a “complication-free” survival of restorations of 88.9%. Conclusions. FFA restorations supported by implants with a knife-edge thread design and nanostructured, calcium-incorporated surface are successful in the short term, with high survival and low complication rates; long-term studies are needed to confirm these outcomes. PMID:28246595

  6. Long-term anisotropic mechanical response of surgical meshes used to repair abdominal wall defects.

    PubMed

    Hernández-Gascón, B; Peña, E; Pascual, G; Rodríguez, M; Bellón, J M; Calvo, B

    2012-01-01

    Routine hernia repair surgery involves the implant of synthetic mesh. However, this type of procedure may give rise to pain and bowel incarceration and strangulation, causing considerable patient disability. The purpose of this study was to compare the long-term behaviour of three commercial meshes used to repair the partially herniated abdomen in New Zealand White rabbits: the heavyweight (HW) mesh, Surgipro(®) and lightweight (LW) mesh, Optilene(®), both made of polypropylene (PP), and a mediumweight (MW) mesh, Infinit(®), made of polytetrafluoroethylene (PTFE). The implanted meshes were mechanical and histological assessed at 14, 90 and 180 days post-implant. This behaviour was compared to the anisotropic mechanical behaviour of the unrepaired abdominal wall in control non-operated rabbits. Both uniaxial mechanical tests conducted in craneo-caudal and perpendicular directions and histological findings revealed substantial collagen growth over the repaired hernial defects causing stiffness in the repair zone, and thus a change in the original properties of the meshes. The mechanical behaviour of the healthy tissue in the craneo-caudal direction was not reproduced by any of the implanted meshes after 14 days or 90 days of implant, whereas in the perpendicular direction, SUR and OPT achieved similar behaviour. From a mechanical standpoint, the anisotropic PP-lightweight meshes may be considered a good choice in the long run, which correlates with the structure of the regenerated tissue. Copyright © 2011 Elsevier Ltd. All rights reserved.

  7. Development and Characterization of a Scalable Microperforated Device Capable of Long-Term Zero Order Drug Release

    DTIC Science & Technology

    2010-06-29

    posterior segment of the eye and include posterior uveitis , age-related macular degeneration, and macular edema (Hsu 2007). Long term drug therapy may be...device for local and controlled delivery of drugs; as a protective carrier to transport labile drugs; and as an implant for treatment of various chronic

  8. Extending Rest between Unloading Cycles Does Not Enhance Bone's Long-Term Recovery.

    PubMed

    Manske, Sarah L; Vijayaraghavan, Surabhi; Tuthill, Alyssa; Brutus, Olivier; Yang, Jie; Gupta, Shikha; Judex, Stefan

    2015-10-01

    Multiple exposures to unloading are overall more deleterious to the skeleton than is single exposure, although the rate of bone loss may diminish during multiple exposures. Here, we determined whether extending the reambulation (RA) period from 3 wk to 9 wk will mitigate bone loss during three distinct 3-wk hindlimb unloading (HLU) periods and enhance long-term recovery in skeletally mature, genetically heterogeneous mice. Female adult mice (4 months old) were subjected to three cycles of 3-wk unloading with 3-wk or 9-wk RA periods in between. Mice were terminated 46 wk after initiation of the study. Outcome measures for the distal femur were determined from multiple in vivo micro-computed tomography scans and finite-element modeling. Tripling RA duration enhanced trabecular bone recovery in between HLU periods but also increased the rate of loss of bone volume fraction (bone volume/tissue volume) and metaphyseal stiffness during subsequent HLU periods. With shorter RA periods, the magnitude of bone loss decreased by the second HLU period, whereas this decrease was delayed with longer RA periods. RA duration did not affect long-term recovery 46 wk after the start of the experimental protocol, as both HLU groups had similar levels of bone volume/tissue volume, cortical area, and stiffness. Individual cage activity levels were unrelated to the magnitude of bone loss during HLU or bone recovery during RA. These data suggest that extending recovery duration between periods of unloading may provide temporary benefits but is an ineffective long-term strategy for combating the devastation of trabecular morphology and mechanics, as temporarily enhanced recovery is largely cancelled out by greater susceptibility to unloading. They also emphasize that cortical bone is more amenable to long-term recovery than is trabecular bone.

  9. Periimplantitis Treatment: Long-Term Comparison of Laser Decontamination and Implantoplasty Surgery.

    PubMed

    Pommer, Bernhard; Haas, Robert; Mailath-Pokorny, Georg; Fürhauser, Rudolf; Watzek, Georg; Busenlechner, Dieter; Müller-Kern, Michael; Kloodt, Claudia

    2016-10-01

    Periimplantitis is the most frequent cause of late implant failure; however, little is known about the long-term success of periimplantitis treatment and the effectiveness of various therapeutic interventions. A total of 142 patients were referred to the Academy for Oral Implantology in Vienna for the treatment of recurrent periimplantitis around single-tooth implants. Of them, 72 patients (51%) were treated by laser decontamination, 47 patients (33%) by implantoplasty surgery, and 23 patients (16%) by a combination of both approaches. Overall success of periimplantitis therapy was 89% after 9 years of follow-up, and it did not differ significantly between female and male patients (P = 0.426). The number of implant failures that could not be prevented by periimplantitis treatment was 6 after laser decontamination (8%), 6 after implantoplasty surgery (13%), and 4 after a combination of both therapies (17%). Implant loss occurred after 4.9 ± 1.9 years of therapy, on average. No significant difference between the 3 treatment groups could be observed (P = 0.393). The present results suggest that success rates of periimplantitis therapy with either laser decontamination or surgical implantoplasty are high. These success rates do not appear to be associated with patient gender or treatment strategy.

  10. Long term assessment of blood pressure transducer drift in rhesus monkeys chronically instrumented with telemetry implants.

    PubMed

    Regan, Hillary K; Lynch, Joseph J; Regan, Christopher P

    2009-01-01

    The accurate assessment of blood pressure is often a key component of preclinical cardiovascular disease/efficacy models and of screening models used to determine the effects of test agents on cardiovascular physiology. Of the many methods utilized in large animals, telemetry is becoming more widely used throughout preclinical testing, and non-human primates are playing an ever increasing role as a large animal model to evaluate the cardiovascular effect of novel test agents. Therefore, we sought to characterize pressure transducer drift of a telemetry implant in primates over an extended duration. We instrumented ten rhesus monkeys with a Konigsberg T27F implant and a chronic indwelling arterial catheter and cross calibrated the diastolic pressure recorded by the implant to the diastolic pressure that was simultaneously recorded through the arterial catheter using a calibrated external transducer/amplifier system. While all implanted pressure transducers experienced drift to some degree, magnitude of drift varied across animals (range of average drift 0.7-20.5 mmHg/month). Specifically, we found that all implants could be calibrated within the voltage range of the instrument up to 6 months after implantation despite the drift observed. Between 6 and 12 months, 3 of the 10 implants studied drifted outside the defined voltage range and were unusable, two more drifted off scale within 2 years, while the remainder remained within the operating voltage range. Given that pressure transducer drift was not consistent across implants or time, these data suggest careful assessment and quantitative correction for in vivo drift of telemetry blood pressure transducers implanted for extended duration should be considered.

  11. The contribution of short-term memory capacity to reading ability in adolescents with cochlear implants.

    PubMed

    Edwards, Lindsey; Aitkenhead, Lynne; Langdon, Dawn

    2016-11-01

    This study aimed to establish the relationship between short-term memory capacity and reading skills in adolescents with cochlear implants. A between-groups design compared a group of young people with cochlear implants with a group of hearing peers on measures of reading, and auditory and visual short-term memory capacity. The groups were matched for non-verbal IQ and age. The adolescents with cochlear implants were recruited from the Cochlear Implant Programme at a specialist children's hospital. The hearing participants were recruited from the same schools as those attended by the implanted adolescents. Participants were 18 cochlear implant users and 14 hearing controls, aged between 12 and 18 years. All used English as their main language and had no significant learning disability or neuro-developmental disorder. Short-term memory capacity was assessed in the auditory modality using Forward and Reverse Digit Span from the WISC IV UK, and visually using Forward and Reverse Memory from the Leiter-R. Individual word reading, reading comprehension and pseudoword decoding were assessed using the WIAT II UK. A series of ANOVAs revealed that the adolescents with cochlear implants had significantly poorer auditory short-term memory capacity and reading skills (on all measures) compared with their hearing peers. However, when Forward Digit Span was entered into the analyses as a covariate, none of the differences remained statistically significant. Deficits in immediate auditory memory persist into adolescence in deaf children with cochlear implants. Short-term auditory memory capacity is an important neurocognitive process in the development of reading skills after cochlear implantation in childhood that remains evident in later adolescence. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. Carbon offers advantages as implant material in human body

    NASA Technical Reports Server (NTRS)

    Benson, J.

    1969-01-01

    Because of such characteristics as high strength and long-term biocompatability, aerospace carbonaceous materials may be used as surgical implants to correct pathological conditions in the body resulting from disease or injury. Examples of possible medical uses include bone replacement, implantation splints and circulatory bypass implants.

  13. Rodent model for assessing the long term safety and performance of peripheral nerve recording electrodes

    NASA Astrophysics Data System (ADS)

    Vasudevan, Srikanth; Patel, Kunal; Welle, Cristin

    2017-02-01

    Objective. In the US alone, there are approximately 185 000 cases of limb amputation annually, which can reduce the quality of life for those individuals. Current prosthesis technology could be improved by access to signals from the nervous system for intuitive prosthesis control. After amputation, residual peripheral nerves continue to convey motor signals and electrical stimulation of these nerves can elicit sensory percepts. However, current technology for extracting information directly from peripheral nerves has limited chronic reliability, and novel approaches must be vetted to ensure safe long-term use. The present study aims to optimize methods to establish a test platform using rodent model to assess the long term safety and performance of electrode interfaces implanted in the peripheral nerves. Approach. Floating Microelectrode Arrays (FMA, Microprobes for Life Sciences) were implanted into the rodent sciatic nerve. Weekly in vivo recordings and impedance measurements were performed in animals to assess performance and physical integrity of electrodes. Motor (walking track analysis) and sensory (Von Frey) function tests were used to assess change in nerve function due to the implant. Following the terminal recording session, the nerve was explanted and the health of axons, myelin and surrounding tissues were assessed using immunohistochemistry (IHC). The explanted electrodes were visualized under high magnification using scanning electrode microscopy (SEM) to observe any physical damage. Main results. Recordings of axonal action potentials demonstrated notable session-to-session variability. Impedance of the electrodes increased upon implantation and displayed relative stability until electrode failure. Initial deficits in motor function recovered by 2 weeks, while sensory deficits persisted through 6 weeks of assessment. The primary cause of failure was identified as lead wire breakage in all of animals. IHC indicated myelinated and unmyelinated axons

  14. Long-term biopersistence of tangled oxidized carbon nanotubes inside and outside macrophages in rat subcutaneous tissue

    NASA Astrophysics Data System (ADS)

    Sato, Yoshinori; Yokoyama, Atsuro; Nodasaka, Yoshinobu; Kohgo, Takao; Motomiya, Kenichi; Matsumoto, Hiroaki; Nakazawa, Eiko; Numata, Tomoko; Zhang, Minfang; Yudasaka, Masako; Hara, Hideyuki; Araki, Rikita; Tsukamoto, Osamu; Saito, Hiroaki; Kamino, Takeo; Watari, Fumio; Tohji, Kazuyuki

    2013-08-01

    Because of their mechanical strength, chemical stability, and low molecular weight, carbon nanotubes (CNTs) are attractive biological implant materials. Biomaterials are typically implanted into subcutaneous tissue or bone; however, the long-term biopersistence of CNTs in these tissues is unknown. Here, tangled oxidized multi-walled CNTs (t-ox-MWCNTs) were implanted into rat subcutaneous tissues and structural changes in the t-ox-MWCNTs located inside and outside of macrophages were studied for 2 years post-implantation. The majority of the large agglomerates were present in the intercellular space, maintained a layered structure, and did not undergo degradation. By contrast, small agglomerates were found inside macrophages, where they were gradually degraded in lysosomes. None of the rats displayed symptoms of cancer or severe inflammatory reactions such as necrosis. These results indicate that t-ox-MWCNTs have high biopersistence and do not evoke adverse events in rat subcutaneous tissue in vivo, demonstrating their potential utility as implantable biomaterials.

  15. Long-range effect in nitrogen ion-implanted AISI 316L stainless steel

    NASA Astrophysics Data System (ADS)

    Budzynski, P.

    2015-01-01

    The effect of nitrogen ion implantation on AISI 316L stainless steel was investigated. The microstructure and composition of an N implanted layer were studied by RBS, GIXRD, SEM, and EDX measurements. Friction and wear tests were also performed. The discrepancy between the measured and calculated stopped ion maximum range does not exceed 0.03 μm. After nitrogen implantation with a fluence of 5 × 1017 ion/cm2, additional phases of expanded austenite were detected. At a 5-fold larger depth than the maximum ion range, improvement in the coefficient of friction and wear was detected. We have shown, for the first time, the long-range effect in tribological investigations. The long-range effect is caused by movement of not only defects along the depth of the sample, as assumed so far, but also nitrogen atoms.

  16. [Long-term psychiatric hospitalizations].

    PubMed

    Plancke, L; Amariei, A

    2017-02-01

    Long-term hospitalizations in psychiatry raise the question of desocialisation of the patients and the inherent costs. Individual indicators were extracted from a medical administrative database containing full-time psychiatric hospitalizations for the period 2011-2013 of people over 16 years old living in the French region of Nord-Pas-de-Calais. We calculated the proportion of people who had experienced a hospitalization with a duration of 292 days or more during the study period. A bivariate analysis was conducted, then ecological data (level of health-care offer, the deprivation index and the size of the municipalities of residence) were included into a multilevel regression model in order to identify the factors significantly related to variability of long-term hospitalization rates. Among hospitalized individuals in psychiatry, 2.6% had had at least one hospitalization of 292 days or more during the observation period; the number of days in long-term hospitalization represented 22.5% of the total of days of full-time hospitalization in psychiatry. The bivariate analysis revealed that seniority in the psychiatric system was strongly correlated with long hospitalization rates. In the multivariate analysis, the individual indicators the most related to an increased risk of long-term hospitalization were: total lack of autonomy (OR=9.0; 95% CI: 6.7-12.2; P<001); diagnoses of psychological development disorders (OR=9.7; CI95%: 4.5-20.6; P<.001); mental retardation (OR=4.5; CI95%: 2.5-8.2; P<.001): schizophrenia (OR=3.0; CI95%: 1.7-5.2; P<.001); compulsory hospitalization (OR=1.7; CI95%: 1.4-2.1; P<.001); having experienced therapeutic isolation (OR=1.8; CI95%: 1.5-2.1; P<.001). Variations of long-term hospitalization rates depending on the type of establishment were very high, but the density of hospital beds or intensity of ambulatory activity services were not significantly linked to long-term hospitalization. The inhabitants of small urban units had

  17. Long-term drug release from electrospun fibers for in vivo inflammation prevention in the prevention of peritendinous adhesions.

    PubMed

    Hu, Changmin; Liu, Shen; Zhang, Yang; Li, Bin; Yang, Huilin; Fan, Cunyi; Cui, Wenguo

    2013-07-01

    Physical barriers such as electrospun fibrous membranes are potentially useful in preventing peritendinous adhesions after surgery. However, inflammatory responses caused by degradation of barrier materials remain a major challenge. This study aimed to fabricate electrospun composite fibrous membranes based on drug-loaded modified mesoporous silica (MMS) and poly (l-lactic acid) (PLLA). Using a co-solvent-based electrospinning method ibuprofen (IBU)-loaded MMS was successfully and uniformly encapsulated in the PLLA fibers. The electrospun PLLA-MMS-IBU composite fibrous membranes showed significantly lower initial burst release (6% release in the first 12h) compared with that of electrospun PLLA-IBU fibrous membranes (46% release in the first 12h) in in vitro release tests. Moreover, the release from PLLA-MMS-IBU was also for significantly longer than that from PLLA-IBU (100 vs. 20days). In animal studies both PLLA-IBU and PLLA-MMS-IBU showed improved anti-adhesion properties and anti-inflammatory effects compared with PLLA fibrous membrane alone 4weeks after implantation. Further, animals implanted with PLLA-MMS-IBU for 8weeks showed the lowest inflammation and best recovery compared with those implanted with PLLA-IBU and PLLA, most likely as a result of its long-term IBU release profile. Therefore, this study provides a platform technique for fabricating fibrous membranes with long-term sustained drug release characteristics which may function as a novel carrier for long-term anti-inflammation and anti-adhesion to prevent peritendinous adhesions. Copyright © 2013 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  18. The long-term in vivo behavior of polymethyl methacrylate bone cement in total hip arthroplasty

    PubMed Central

    2011-01-01

    Background and purpose The long-term success of cemented total hip arthroplasty (THA) has been well established. Improved outcomes, both radiographically and clinically, have resulted mainly from advances in stem design and improvements in operating techniques. However, there is concern about the durability of bone cement in vivo. We evaluated the physical and chemical properties of CMW1 bone cements retrieved from patients undergoing revision THA. Methods CMW1 cements were retrieved from 14 patients who underwent acetabular revision because of aseptic loosening. The time in vivo before revision was 7–30 years. The bending properties of the retrieved bone cement were assessed using the three-point bending method. The molecular weight and chemical structure were analyzed by gel permeation chromatography and Fourier-transform infrared spectroscopy. The porosity of the bone cements was evaluated by 3-D microcomputer tomography. Results The bending strength decreased with increasing time in vivo and depended on the density of the bone cement, which we assume to be determined by the porosity. There was no correlation between molecular weight and time in vivo. The infrared spectra were similar in the retrieved cements and in the control CMW1 cements. Interpretation Our results indicate that polymer chain scission and significant hydrolysis do not occur in CMW1 cement after implantation in vivo, even in the long term. CMW1 cement was stable through long-term implantation and functional loading. PMID:22103279

  19. Lesion length impacts long term outcomes of drug-eluting stents and bare metal stents differently.

    PubMed

    Chang, Shang-Hung; Chen, Chun-Chi; Hsieh, Ming-Jer; Wang, Chao-Yung; Lee, Cheng-Hung; Hsieh, I-Chang

    2013-01-01

    Long lesions have been associated with adverse outcomes in percutaneous coronary interventions with bare metal stents (BMS). However, the exact impact of lesion length on the short- and long-term outcomes of drug-eluting stent (DES) implantations is not as clear. This study compared the impact of lesion length on angiographic and clinical outcomes of BMS and DES in a single-center prospective registry. Lesion length was divided into tertiles. The primary endpoints were angiographically defined binary in-stent restenosis (ISR) rate and major adverse cardiac event (MACE). Of the 4,312 de novo lesions in 3,447 consecutive patients in the CAPTAIN registry, 2,791 lesions (of 2,246 patients) received BMS, and the remaining 1,521 lesions (of 1,201 patients) received DES. The mean follow-up duration was 4.5 years. The longer the lesion, the higher the ISR rate (14%, 18%, and 29%, p<0.001) and the lower the MACE-free survivals (p = 0.007) in the BMS group. However, lesion length showed no such correlation with ISR rates (4.7%, 3.3%, and 7.8%, p = 0.67) or MACE-free survivals (p = 0.19) in the DES group. In our single-center prospective registry, lesion length defined in tertiles has no impact on the short-term (ISR) or long-term (MACE) outcomes of patients implanted with DES. In contrast, longer lesion correlates with higher ISR and MACE rates in BMS group.

  20. Compatibility of electrolytically produced sodium hypochlorite solutions on long- term implanted dialysis catheters.

    PubMed

    Mishkin, G J

    2007-01-01

    More than 20% of the world's population use a catheter for dialysis, despite guidelines limiting their use. Although the structure and design of the catheters differ by manufacturer, the material used in central venous catheters and peritoneal dialysis catheters are the same across manufacturers. Given the long-term use of these catheters in the dialysis population, the good compatibility of the antiseptics and disinfectants used on the catheters is imperative to prevent failure and cracking of the catheter material. Tensile strengths of commercially available catheters were measured after exposure to commonly used disinfectants. The tensile strength was then compared between the catheters by analyzing the displacement vs. force (N) curves produced during the evaluation. A total of 44 catheter lumens were evaluated. The electrolytically produced sodium hypochlorite solution, Alcavis 50/ExSept Plus, was the only solution shown to be compatible with all three catheter materials resulting in a deviation of less than 10% for each of the different catheter types. Electrolytically produced sodium hypochlorite solutions were the only solutions in this study that did not alter the physical properties of any of the catheters after long-term exposure.

  1. Long-term antibiotic delivery by chitosan-based composite coatings with bone regenerative potential

    NASA Astrophysics Data System (ADS)

    Ordikhani, F.; Simchi, A.

    2014-10-01

    Composite coatings with bone-bioactivity and drug-eluting capacity are considered as promising materials for titanium bone implants. In this work, drug-eluting chitosan-bioactive glass coatings were fabricated by a single-step electrophoretic deposition technique. Drug-loading and -releasing capacity of the composite coatings were carried out using the vancomycin antibiotic. Uniform coatings with a thickness of ∼55 μm containing 23.7 wt% bioactive glass particles and various amounts of the antibiotic (380-630 μg/cm2) were produced. The coatings were bioactive in terms of apatite-forming ability in simulated body fluid and showed favorable cell adhesion and growth. In vitro biological tests also indicated that the composite coatings had better cellular affinity than pristine chitosan coatings. The in vitro elution kinetics of the composite coating revealed an initial burst release of around 40% of the drug within the first elution step of 1 h and following by a continuous eluting over 4 weeks, revealing long-term drug-delivering potential. Antibacterial tests using survival assay against Gram-positive Staphylococcus aureus bacteria determined the effect of vancomycin release on reduction of infection risk. Almost no bacteria were survived on the coatings prepared from the EPD suspension containing ≥0.5 g/l vancomycin. The developed chitosan-based composite coatings with bone bioactivity and long-term drug-delivery ability may be potentially useful for metallic implants to reduce infection risk.

  2. Effect of long-term industrial waste effluent pollution on soil enzyme activities and bacterial community composition.

    PubMed

    Subrahmanyam, Gangavarapu; Shen, Ju-Pei; Liu, Yu-Rong; Archana, Gattupalli; Zhang, Li-Mei

    2016-02-01

    Although numerous studies have addressed the influence of exogenous pollutants on microorganisms, the effect of long-term industrial waste effluent (IWE) pollution on the activity and diversity of soil bacteria was still unclear. Three soil samples characterized as uncontaminated (R1), moderately contaminated (R2), and highly contaminated (R3) receiving mixed organic and heavy metal pollutants for more than 20 years through IWE were collected along the Mahi River basin, Gujarat, western India. Basal soil respiration and in situ enzyme activities indicated an apparent deleterious effect of IWE on microbial activity and soil function. Community composition profiling of soil bacteria using 16S rRNA gene amplification and denaturing gradient gel electrophoresis (DGGE) method indicated an apparent bacterial community shift in the IWE-affected soils. Cloning and sequencing of DGGE bands revealed that the dominated bacterial phyla in polluted soil were affiliated with Firmicutes, Acidobacteria, and Actinobacteria, indicating that these bacterial phyla may have a high tolerance to pollutants. We suggested that specific bacterial phyla along with soil enzyme activities could be used as relevant biological indicators for long-term pollution assessment on soil quality. Graphical Abstract Bacterial community profiling and soil enzyme activities in long-term industrial waste effluent polluted soils.

  3. Long-term efficacy and safety of thalamic stimulation for drug-resistant partial epilepsy

    PubMed Central

    Witt, Thomas; Worth, Robert; Henry, Thomas R.; Gross, Robert E.; Nazzaro, Jules M.; Labar, Douglas; Sperling, Michael R.; Sharan, Ashwini; Sandok, Evan; Handforth, Adrian; Stern, John M.; Chung, Steve; Henderson, Jaimie M.; French, Jacqueline; Baltuch, Gordon; Rosenfeld, William E.; Garcia, Paul; Barbaro, Nicholas M.; Fountain, Nathan B.; Elias, W. Jeffrey; Goodman, Robert R.; Pollard, John R.; Tröster, Alexander I.; Irwin, Christopher P.; Lambrecht, Kristin; Graves, Nina; Fisher, Robert

    2015-01-01

    Objective: To report long-term efficacy and safety results of the SANTE trial investigating deep brain stimulation of the anterior nucleus of the thalamus (ANT) for treatment of localization-related epilepsy. Methods: This long-term follow-up is a continuation of a previously reported trial of 5- vs 0-V ANT stimulation. Long-term follow-up began 13 months after device implantation with stimulation parameters adjusted at the investigators' discretion. Seizure frequency was determined using daily seizure diaries. Results: The median percent seizure reduction from baseline at 1 year was 41%, and 69% at 5 years. The responder rate (≥50% reduction in seizure frequency) at 1 year was 43%, and 68% at 5 years. In the 5 years of follow-up, 16% of subjects were seizure-free for at least 6 months. There were no reported unanticipated adverse device effects or symptomatic intracranial hemorrhages. The Liverpool Seizure Severity Scale and 31-item Quality of Life in Epilepsy measure showed statistically significant improvement over baseline by 1 year and at 5 years (p < 0.001). Conclusion: Long-term follow-up of ANT deep brain stimulation showed sustained efficacy and safety in a treatment-resistant population. Classification of evidence: This long-term follow-up provides Class IV evidence that for patients with drug-resistant partial epilepsy, anterior thalamic stimulation is associated with a 69% reduction in seizure frequency and a 34% serious device-related adverse event rate at 5 years. PMID:25663221

  4. Long-term results following titanium cranioplasty of large skull defects.

    PubMed

    Cabraja, Mario; Klein, Martin; Lehmann, Thomas-Nikolas

    2009-06-01

    Decompressive craniectomy is an established procedure to lower intracranial pressure. Therefore, cranioplasty remains a necessity in neurosurgery as well. If the patient's own bone flap is not available, the surgeon can choose between various alloplast grafts. A review of the literature proves that 4-13.8% of polymethylmethacrylate plates and 2.6-10% of hydroxyapatite-based implants require replacement. In this retrospective study of large skull defects, the authors compared computer-assisted design/computer-assisted modeled (CAD/CAM) titanium implants for cranioplasty with other frequently used materials described in literature. Twenty-six patients underwent cranioplasty with CAD/CAM titanium implants (mean diameter 112 mm). With the aid of visual analog scales, the patients' pain and cosmesis were evaluated 6-12 years (mean 8.1 years) after insertion of the implants. None of the implants had to be removed. Of all patients, 68% declared their outcomes as excellent, 24% as good, 0.8% as fair, and 0% as poor. There was no resulting pain in 84% of the patients, and 88% were satisfied with the cosmetic result, noting > 75 mm on the visual analog scale of cosmesis. All patients would have chosen cranioplasty again, stating an improvement in their quality of life by the calvarial reconstruction. Nevertheless, follow-up images obtained in 4 patients undergoing removal of meningiomas was only suboptimal. With the aid of CAD technology, all currently used alloplastic materials are suited even for large skull defect cranioplasty. Analysis of the authors' data and the literature shows that cranioplasty with CAD/CAM titanium implants provides the lowest rate of complications, reasonable costs, and acceptable postoperative imaging. Polymethylmethacrylate is suited for primary cranioplasty or for long-term follow-up imaging of tumors. Titanium implants seem to be the material of choice for secondary cranioplasty of large skull defects resulting from decompressive craniectomy

  5. Long-term potentiation and long-term depression: a clinical perspective

    PubMed Central

    Bliss, Timothy V.P.; Cooke, Sam F

    2011-01-01

    Long-term potentiation and long-term depression are enduring changes in synaptic strength, induced by specific patterns of synaptic activity, that have received much attention as cellular models of information storage in the central nervous system. Work in a number of brain regions, from the spinal cord to the cerebral cortex, and in many animal species, ranging from invertebrates to humans, has demonstrated a reliable capacity for chemical synapses to undergo lasting changes in efficacy in response to a variety of induction protocols. In addition to their physiological relevance, long-term potentiation and depression may have important clinical applications. A growing insight into the molecular mechanisms underlying these processes, and technological advances in non-invasive manipulation of brain activity, now puts us at the threshold of harnessing long-term potentiation and depression and other forms of synaptic, cellular and circuit plasticity to manipulate synaptic strength in the human nervous system. Drugs may be used to erase or treat pathological synaptic states and non-invasive stimulation devices may be used to artificially induce synaptic plasticity to ameliorate conditions arising from disrupted synaptic drive. These approaches hold promise for the treatment of a variety of neurological conditions, including neuropathic pain, epilepsy, depression, amblyopia, tinnitus and stroke. PMID:21779718

  6. Long-term effectiveness of surgical treatment of ectopic atrial tachycardia.

    PubMed

    Prager, N A; Cox, J L; Lindsay, B D; Ferguson, T B; Osborn, J L; Cain, M E

    1993-07-01

    The purpose of this study was to determine the long-term clinical outcome of patients with ectopic atrial tachycardias treated surgically. Ectopic atrial tachycardia is an uncommon arrhythmia that can be symptomatic and is associated with the development of a cardiomyopathy. Management strategies are not well defined because of the paucity of data on the long-term effectiveness of pharmacologic and nonpharmacologic therapies. The long-term clinical impact of medical and surgical therapy was determined in 15 consecutive patients with ectopic atrial tachycardia. All 15 patients were initially treated with antiarrhythmic drugs (mean 5.7 +/- 2.2 drugs/patient). An effective drug regimen was identified in only 5 (33%) of the 15 patients; the remaining 10 patients were treated surgically. In each, individualized surgical procedures were guided by computer-assisted intraoperative mapping, with atrial plaques comprising up to 156 electrodes. Focal ablation was performed in four patients and atrial isolation procedures in six. The 10 patients treated surgically were followed up a mean of 4 +/- 3.2 years. Ectopic atrial tachycardia recurred in one patient. A permanent pacemaker was implanted in two patients, one of whom also required reoperation for constrictive pericarditis. There were no operative deaths. Ectopic atrial tachycardia recurred in three (60%) of the five patients discharged on antiarrhythmic drug therapy during a mean follow-up interval of 6.4 +/- 4.3 years. There was one nonarrhythmic death. Map-guided surgery demonstrated long-term efficacy in abolishing symptoms in 9 of the 10 patients with ectopic atrial tachycardia. Results demonstrate that surgery is effective for patients with ectopic atrial tachycardias who are not easily treated with antiarrhythmic drugs.

  7. Genetic Drift, Not Life History or RNAi, Determine Long-Term Evolution of Transposable Elements

    PubMed Central

    Szitenberg, Amir; Cha, Soyeon; Opperman, Charles H.; Bird, David M.; Blaxter, Mark L.; Lunt, David H.

    2016-01-01

    Abstract Transposable elements (TEs) are a major source of genome variation across the branches of life. Although TEs may play an adaptive role in their host’s genome, they are more often deleterious, and purifying selection is an important factor controlling their genomic loads. In contrast, life history, mating system, GC content, and RNAi pathways have been suggested to account for the disparity of TE loads in different species. Previous studies of fungal, plant, and animal genomes have reported conflicting results regarding the direction in which these genomic features drive TE evolution. Many of these studies have had limited power, however, because they studied taxonomically narrow systems, comparing only a limited number of phylogenetically independent contrasts, and did not address long-term effects on TE evolution. Here, we test the long-term determinants of TE evolution by comparing 42 nematode genomes spanning over 500 million years of diversification. This analysis includes numerous transitions between life history states, and RNAi pathways, and evaluates if these forces are sufficiently persistent to affect the long-term evolution of TE loads in eukaryotic genomes. Although we demonstrate statistical power to detect selection, we find no evidence that variation in these factors influence genomic TE loads across extended periods of time. In contrast, the effects of genetic drift appear to persist and control TE variation among species. We suggest that variation in the tested factors are largely inconsequential to the large differences in TE content observed between genomes, and only by these large-scale comparisons can we distinguish long-term and persistent effects from transient or random changes. PMID:27566762

  8. Current trends in dental implants

    PubMed Central

    Gaviria, Laura; Salcido, John Paul; Guda, Teja

    2014-01-01

    Tooth loss is very a very common problem; therefore, the use of dental implants is also a common practice. Although research on dental implant designs, materials and techniques has increased in the past few years and is expected to expand in the future, there is still a lot of work involved in the use of better biomaterials, implant design, surface modification and functionalization of surfaces to improve the long-term outcomes of the treatment. This paper provides a brief history and evolution of dental implants. It also describes the types of implants that have been developed, and the parameters that are presently used in the design of dental implants. Finally, it describes the trends that are employed to improve dental implant surfaces, and current technologies used for the analysis and design of the implants. PMID:24868501

  9. Long-term results of the use of silicone sheets after diskectomy in the temporomandibular joint: clinical, radiographic and histopathologic findings.

    PubMed

    Schliephake, H; Schmelzeisen, R; Maschek, H; Haese, M

    1999-10-01

    The aim of the present study was to evaluate the long-term results of a group of patients who had the disk of the temporomandibular joint (TMJ) removed and permanently replaced by a silicone sheet. The study group comprised 48 patients, treated in the period from 1983 to 1993. In eight patients, the implants had to be removed after an average interval of 5.6 years and they were submitted for histopathological examination. Twenty-five of the 40 patients with silastic implants in place, and five of the 8 patients who had their implants removed, were available for long-term follow-up (mean interval of 7.0 years, SD 2.8 years). Clinical function was rated according to the Helkimo Dysfunction Index and compared to the preoperative findings. Results showed decreased tenderness of muscles and joints to palpation and increased mouth opening, but no statistically significant improvement in joint function. In 4 patients, a decrease in condylar width was found, while another 4 patients presented with thickening of the condyle by appositional bone formation. Histopathology of the failed implants showed scattered fragments of silastic material and dacron fibers with accumulation of histiocytes in immediate contact with the silicone particles and phagocytozed intracellular material. T-lymphocytes were also present in the vicinity of the silicone particles.

  10. Long-term in vivo left ventricular assist device study for 284 days with Gyro PI pump.

    PubMed

    Ohtsuka, G; Nakata, K; Yoshikawa, M; Takano, T; Glueck, J; Sankai, Y; Takami, Y; Mueller, J; Sueoka, A; Letsou, G; Schima, H; Schmallegger, H; Wolner, E; Koyanagi, H; Fujisawa, A; Baldwin, J C; Nosé, Y

    1999-06-01

    A totally implantable centrifugal artificial heart has been developed. The plastic prototype, the Gyro PI 601, passed 2 day hemodynamic tests as a functional total artificial heart (TAH), 2 week screening tests for anti-thrombogenecity, and a 1 month system feasibility study. Based upon these results, a metallic prototype, the Gyro PI 700 series, was subjected to long-term in vivo left ventricular assist device (LVAD) studies of over 1 month. The Gyro PI 700 series has the same inner dimension and same characteristics of the Gyro PI 601 such as an eccentric inlet port, a double pivot bearing system, and a magnet coupling system. The PI metallic pump is also driven with the Vienna DC brushless motor actuator like the PI 601. The pump-actuator package was implanted in 3 calves in the preperitoneal space, bypassing from the left ventricular (LV) apex to the descending aorta. Case 1 achieved a 284 day survival. Case 2 was euthanized early at 72 postoperative days as a result of the functional obstruction of the inlet port due to the excessive growth of the calf. There was no blood clot inside the pumps of either case. Case 3 is on-going (22 days on July 24, 1998). During these periods, all cases showed no physiological abnormalities. In conclusion, the PI 700 series pump has excellent results as a long-term implantable LVAD.

  11. Nursing Home Use After Implantable Cardioverter-Defibrillator Implantation in Older Adults: Results from the National Cardiovascular Data Registry.

    PubMed

    Kramer, Daniel B; Reynolds, Matthew R; Normand, Sharon-Lise; Parzynski, Craig S; Spertus, John A; Mor, Vincent; Mitchell, Susan L

    2017-02-01

    To evaluate the incidence and characteristics of nursing home (NH) use after implantable cardioverter-defibrillator (ICD) implantation. Cohort study. Medicare beneficiaries in the National Cardiovascular Data Registry-ICD Registry. Individuals aged 65 and older receiving ICDs between January 1, 2006, and March 31, 2010 (N = 192,483). Proportion of ICD recipients discharged to NHs directly after device placement, cumulative incidence of long-term NH admission, and factors associated with immediate discharge to a NH and time to long-term NH admission. Over 4 years, 40.6% of the cohort died, and 35,939 (18.7%) experienced at least one NH admission, including 4.0% directly discharged to a NH after ICD implantation and 2.8% admitted to long-term NH care during follow-up. The cumulative incidence of long-term NH admission, accounting for the competing risk of death, was 1.7% at 1 year, 3.8% at 3 years, and 4.6% at 4 years; 20.1% of individuals admitted to a NH died there. Factors most strongly associated with direct NH discharge and time to long-term NH care were older age (adjusted odds ratio (AOR) = 2.09, 95% confidence interval (CI) = 2.01-2.17 per 10-year increment; adjusted hazard ratio (AHR) = 1.88, 95% CI = 1.80-1.97, respectively), dementia (AOR = 2.60, 95% CI = 2.25-3.01; AHR = 2.50, 95% CI = 2.14-2.93, respectively), and Medicare Part A claim for NH stay in prior 6 months (AOR = 3.96, 95% CI = 3.70-4.25; AHR = 2.88, 95% CI = 2.65-3.14, respectively). Nearly one in five individuals are admitted to NHs over a median of 1.6 years of follow-up after ICD implantation. Understanding these outcomes may help inform the clinical care of these individuals. © 2016, Copyright the Authors Journal compilation © 2016, The American Geriatrics Society.

  12. [Mid-Term to Long-Term Results of Revision Total Hip Arthroplasty Using the Oval-Shaped Acetabular Cup - TC Type].

    PubMed

    Šťastný, E; Trč, T; Frýdl, J; Kopečný, Z; Philippou, T; Lisý, J

    2017-01-01

    INTRODUCTION The purpose of our paper is to evaluate the mid-term to long-term results and to confirm the basic criteria of a high-quality revision implant: safe bridging of bone defects, achievement of reliable primary fixation of revision acetabular cup, achievement of good secondary stability with documentable osteointegration of cup and demonstration of remodelling of transplanted bone tissue in the area of defects and in spaces between the implant ribs. MATERIAL AND METHODS Altogether 36 patients (38 cups) were evaluated who had undergone revision hip arthroplasty in the period from 2004 to 2010. The mean follow-up was 8.2 years (5.1-11.6 years after the reimplantation, more than 10 years in 16 patients who underwent surgery). The position and osseointegration of the implant were assessed by digital radiography, the remodelling of transplanted bone tissues in the area of defects and between the implant ribs by computed tomography with reducing artefacts around the metal implant (Aquilion 64 - Toshiba Medical Systems), and for the clinical outcomes the Harris Hip Score was used. RESULTS Preoperatively, the condition of the hip joint based on the Harris Hip Score was in 30 cases evaluated as poor, in 8 patients as satisfactory. At the time of final evaluation, 8 patients achieved excellent results, in 19 patients the condition of the joint was very good (in 2 patients bilaterally), in 6 patients it was considered satisfactory and in 3 patients poor. The mean value for HHS increased from 39.5 to 84.5. Based on the radiography evaluation, in 27 patients (in 2 patients bilaterally) the osseointegration of the revision cup was good, in 8 cases with a radiolucent line of 2-4 mm in width in DeLee zone III, in one case proximal migration of the cup occurred caused by deep infection. The informed consent form for pelvic CT was signed by 25 patients of our cohort. Remodelling of bone tissue in the space between the ribs of the implant was always detected, the presence of

  13. Verbal Processing Speed and Executive Functioning in Long-Term Cochlear Implant Users

    ERIC Educational Resources Information Center

    AuBuchon, Angela M.; Pisoni, David B.; Kronenberger, William G.

    2015-01-01

    Purpose: The purpose of this study was to report how "verbal rehearsal speed" (VRS), a form of covert speech used to maintain verbal information in working memory, and another verbal processing speed measure, perceptual encoding speed, are related to 3 domains of executive function (EF) at risk in cochlear implant (CI) users: verbal…

  14. Long-term physical exercise and atrial natriuretic peptide in obese Zucker rats.

    PubMed

    Pörsti, Ilkka; Kähönen, Mika; Wu, Xiumin; Arvola, Pertti; Ruskoaho, Heikki

    2002-07-01

    Endurance training increases natriuretic peptide synthesis in the hypertrophied myocardium of spontaneously hypertensive rats. We examined the effects of 22-week-long treadmill exercise on plasma and tissue atrial natriuretic peptide in Zucker rats, a model of genetic obesity and moderate hypertension without clear cardiac hypertrophy. The blood pressures of the animals were measured by the tail-cuff method, and plasma and tissue samples for the peptide determinations were taken at the end of the study. The training increased heart weight to body weight ratio, while atrial natriuretic peptide contents in the right and left atrium, ventricular tissue, and plasma did not change. The exercise prevented the elevation of blood pressure, which was observed in non-exercised obese Zucker rats, and also reduced blood pressure in the lean rats. In conclusion, these results suggest that in the absence of preceding myocardial hypertrophy, the long-term exercise-induced workload is not deleterious to the heart in experimental obesity, since no changes in plasma and tissue atrial natriuretic peptide were detected.

  15. Medium- to Long-Term Results of the Nexgen Legacy Posterior Stabilized Fixed-Bearing Knee Replacement.

    PubMed

    Arikupurathu, Oommen Mathew; Johnston, Linda; MacInnes, Alasdair; Nicol, Graeme; Nassif, Manhal

    2018-06-20

    The NexGen legacy posterior stabilized (LPS) prosthesis was introduced in 1997 after many design changes to its predecessor, the Insall-Burstein II prosthesis. However, there have been no reported long-term studies on the performance of this implant. Prospectively, collected data from a local database comprising primary total knee replacements (TKRs) with LPS between 1997 and 2002 was analyzed. All implants were fixed with cement. Patients were followed up at 1, 3, 5, 7, and 10 years, with patient satisfaction, range of movement, and Knee Society score (KSS) assessed. A total of 621 primary TKRs were analyzed with an average follow-up of 11.25 years (9.15-14.55). The mean age was 69.53 years. The mean KSS was 88.97 and mean flexion increased from 88.3 to 103.5 degrees at 10 years. Kaplan-Meier's analysis revealed a survivorship of 96.5% with revision for any reason as the end point and 98.9% if aseptic loosening was the reason for revision at 14 years. This study revealed excellent mid- to long-term results with the NexGen LPS prosthesis. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  16. The effect of long-term corticosterone treatment on blood cell differentials and function in laboratory and wild-caught amphibian models.

    PubMed

    Falso, Paul G; Noble, Christopher A; Diaz, Jesus M; Hayes, Tyrone B

    2015-02-01

    The effect of long-term stress on amphibian immunity is not well understood. We modeled a long-term endocrine stress scenario by elevating plasma corticosterone in two species of amphibians and examined effects on white blood cell differentials and innate immune activity. Plasma corticosterone was elevated in American bullfrogs (Lithobates catesbeianus) by surgically implanting corticosterone capsules and in African clawed frogs (Xenopus laevis) by immersion in corticosterone-treated water. To provide a context for our results within endogenous corticosterone fluctuations, diurnal plasma corticosterone cycles were determined. A daily low of corticosterone was observed in X. laevis at 12:00, while a significant pattern was not observed in L. catesbeianus. Elevated plasma corticosterone levels increased the ratio of peripheral neutrophils to lymphocytes, in both species, and decreased eosinophil concentrations in L. catesbeianus over a long-term period. Whole blood oxidative burst generally correlated with neutrophil concentrations, and thus was increased with corticosterone treatment, significantly in L. catesbeianus. In L. catesbeianus, an endogenous response of eosinophils and lymphocytes to implanted empty (sham) capsules was observed, but this effect was attenuated by corticosterone. Peripheral monocyte and basophil concentrations were not significantly altered by corticosterone treatment in either species. Our results show that long-term stress can alter amphibian immune parameters for extended periods and may play a role in susceptibility to disease. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Expanded polytetrafluoroethylene membrane alters tissue response to implanted Ahmed glaucoma valve.

    PubMed

    DeCroos, Francis Char; Ahmad, Sameer; Kondo, Yuji; Chow, Jessica; Mordes, Daniel; Lee, Maria Regina; Asrani, Sanjay; Allingham, R Rand; Olbrich, Kevin C; Klitzman, Bruce

    2009-07-01

    Long-term intraocular pressure control by glaucoma drainage implants is compromised by the formation of an avascular fibrous capsule that surrounds the glaucoma implant and increases aqueous outflow resistance. It is possible to alter this fibrotic tissue reaction and produce a more vascularized and potentially more permeable capsule around implanted devices by enclosing them in a porous membrane. Ahmed glaucoma implants modified with an outer 5-microm pore size membrane (termed porous retrofitted implant with modified enclosure or PRIME-Ahmed) and unmodified glaucoma implants were implanted into paired rabbit eyes. After 6 weeks, the devices were explanted and subject to histological analysis. A tissue response containing minimal vascularization, negligible immune response, and a thick fibrous capsule surrounded the unmodified Ahmed glaucoma implant. In comparison, the tissue response around the PRIME-Ahmed demonstrated a thinner fibrous capsule (46.4 +/- 10.8 microm for PRIME-Ahmed versus 94.9 +/- 21.2 microm for control, p < 0.001) and was highly vascularized near the tissue-material interface. A prominent chronic inflammatory response was noted as well. Encapsulating the aqueous outflow pathway with a porous membrane produces a more vascular tissue response and thinner fibrous capsule compared with a standard glaucoma implant plate. Enhanced vascularity and a thinner fibrous capsule may reduce aqueous outflow resistance and improve long-term glaucoma implant performance.

  18. Flexible endoscopy for pediatric tracheobronchial metallic stent placement, maintenance and long-term outcomes

    PubMed Central

    2018-01-01

    Objectives To assess the placement, surveillance management and long-term outcomes of the tracheobronchial (TB) balloon expandable metallic stent (BEMS) managed by therapeutic flexible endoscopy (TFE). Methods This is a retrospective review and analysis of all computerized medical records and related flexible endoscopy videos of pediatric patients who received TB BEMS during 20 years period, from January 1997 to December 2016. TFE techniques with forceps debridement, balloon dilatation and laser ablation were used to implant stents, perform regular surveillance, maintain their functions, and expand the diameters of BEMS. Short-length (30cm-36cm) endoscopes of OD 3.2mm to 5.0mm coupled with the noninvasive ventilation, without ventilation bag, mask or airway tube, supported the whole procedures. Results 146 BEMS were implanted in 87 consecutive children, including 84 tracheal, 15 carinal and 47 bronchial stents. At the time of placement, the mean age was 35.6 ± 54.6 month-old (range 0.3–228) and the mean body weight was 13.9 ± 10.6 kg (range 2.2–60). Surveillance period was 9.4 ± 6.7 years (range, 0.3–18.0). Satisfactory clinical improvements were noted immediately in all but two patients. Seventy-two (82.8%) patients were still alive with stable respiratory status, except two patients necessitating TFE management every two months. Fifty-one stents, including 35 tracheal and 16 bronchial ones, were successfully retrieved mainly with rigid endoscopy. Implanted stents could be significantly (< .001) further expanded for growing TB lumens. The final stent diameters were positively correlated to the implanted duration. Altogether, 33 stents expired (15 patients), 51 were retrieved (40 patients), and 62 remained and functioning well (38 patients), with their mean duration of 7.4 ± 9.5, 34.9 ± 36.3 and 82.3 ± 62.5 months, respectively. Conclusion In pediatric patients, TFE with short-length scopes coupled with this NIV support has provided a safe, feasible and

  19. Effect of renal sympathetic denervation on the progression of paroxysmal atrial fibrillation in canines with long-term intermittent atrial pacing.

    PubMed

    Wang, Xule; Huang, Congxin; Zhao, Qingyan; Huang, He; Tang, Yanhong; Dai, Zixuan; Wang, Xiaozhan; Guo, Zongwen; Xiao, Jinping

    2015-04-01

    The aim of the present study was to explore the effect of renal sympathetic denervation (RSD) on the progression of paroxysmal atrial fibrillation (AF) in canines with long-term intermittent atrial pacing. Nineteen beagles were randomly divided into sham-operated group (six dogs), control group (six dogs), and RSD group (seven dogs). Sham-operated group were implanted with pacemakers without pacing; control group were implanted with pacemakers with long-term intermittent atrial pacing; and RSD group underwent catheter-based RSD bilaterally and were simultaneously implanted with pacemakers. Atrial pacing was maintained for 8 h a day and a total of 12 weeks in the control group and RSD group. Echocardiography showed that the left atrial structure and function were significantly improved in the RSD group compared with the control group (P < 0.05). Compared with the control group, the RSD group had fewer incidences of AF and a shorter duration of AF (P < 0.05) after long-term intermittent atrial pacing. In addition to increased atrial effective refractory period (AERP) and AF cycle length, AERP dispersion and P-wave duration and dispersion were significantly decreased in the RSD group compared with the control group (P < 0.05). Atrial morphological evaluation suggested that fibrosis and ultrastructural changes induced by long-term intermittent atrial pacing were markedly suppressed in the RSD dogs compared with controls (P < 0.05). Immunohistochemistry results showed that connexin 43 distribution in RSD mid-myocardial was significantly fewer heterogeneous than that in control mid-myocardial (P < 0.05). Renal denervation inhibits the progression of paroxysmal AF, which might be related to the suppression of atrial electrophysiology and structural heterogeneity. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  20. Childhood and adolescent obesity and long-term cognitive consequences during aging.

    PubMed

    Wang, Jun; Freire, Daniel; Knable, Lindsay; Zhao, Wei; Gong, Bing; Mazzola, Paolo; Ho, Lap; Levine, Samara; Pasinetti, Giulio M

    2015-04-01

    The prevalence of childhood/adolescent obesity and insulin resistance has reached an epidemic level. Obesity's immediate clinical impacts have been extensively studied; however, current clinical evidence underscores the long-term implications. The current study explored the impacts of brief childhood/adolescent obesity and insulin resistance on cognitive function in later life. To mimic childhood/adolescent obesity and insulin resistance, we exposed 9-week-old C57BL/6J mice to a high-fat diet for 15 weeks, after which the mice exhibited diet-induced obesity and insulin resistance. We then put these mice back on a normal low-fat diet, after which the mice exhibited normal body weight and glucose tolerance. However, a spatial memory test in the forms of the Morris water maze (MWM) and contextual fear conditioning at 85 weeks of age showed that these mice had severe deficits in learning and long-term memory consolidation. Mechanistic investigations identified increased expression of histone deacetylases 5, accompanied by reduced expression of brain-derived neurotrophic factor, in the brains 61 weeks after the mice had been off the high-fat diet. Electrophysiology studies showed that hippocampal slices isolated from these mice are more susceptible to synaptic impairments compared with slices isolated from the control mice. We demonstrated that a 15-week occurrence of obesity and insulin resistance during childhood/adolescence induces irreversible epigenetic modifications in the brain that persist following restoration of normal metabolic homeostasis, leading to brain synaptic dysfunction during aging. Our study provides experimental evidence that limited early-life exposure to obesity and insulin resistance may have long-term deleterious consequences in the brain, contributing to the onset/progression of cognitive dysfunction during aging. © 2014 Wiley Periodicals, Inc.

  1. Long-term blood glucose monitoring with implanted telemetry device in conscious and stress-free cynomolgus monkeys.

    PubMed

    Wang, B; Sun, G; Qiao, W; Liu, Y; Qiao, J; Ye, W; Wang, H; Wang, X; Lindquist, R; Wang, Y; Xiao, Y-F

    2017-09-01

    Continuous blood glucose monitoring, especially long-term and remote, in diabetic patients or research is very challenging. Nonhuman primate (NHP) is an excellent model for metabolic research, because NHPs can naturally develop Type 2 diabetes mellitus (T2DM) similarly to humans. This study was to investigate blood glucose changes in conscious, moving-free cynomolgus monkeys (Macaca fascicularis) during circadian, meal, stress and drug exposure. Blood glucose, body temperature and physical activities were continuously and simultaneously recorded by implanted HD-XG telemetry device for up to 10 weeks. Blood glucose circadian changes in normoglycemic monkeys significantly differed from that in diabetic animals. Postprandial glucose increase was more obvious after afternoon feeding. Moving a monkey from its housing cage to monkey chair increased blood glucose by 30% in both normoglycemic and diabetic monkeys. Such increase in blood glucose declined to the pre-procedure level in 30 min in normoglycemic animals and >2 h in diabetic monkeys. Oral gavage procedure alone caused hyperglycemia in both normoglycemic and diabetic monkeys. Intravenous injection with the stress hormones, angiotensin II (2 μg/kg) or norepinephrine (0.4 μg/kg), also increased blood glucose level by 30%. The glucose levels measured by the telemetry system correlated significantly well with glucometer readings during glucose tolerance tests (ivGTT or oGTT), insulin tolerance test (ITT), graded glucose infusion (GGI) and clamp. Our data demonstrate that the real-time telemetry method is reliable for monitoring blood glucose remotely and continuously in conscious, stress-free, and moving-free NHPs with the advantages highly valuable to diabetes research and drug discovery.

  2. The role of the interactome in the maintenance of deleterious variability in human populations.

    PubMed

    Garcia-Alonso, Luz; Jiménez-Almazán, Jorge; Carbonell-Caballero, Jose; Vela-Boza, Alicia; Santoyo-López, Javier; Antiñolo, Guillermo; Dopazo, Joaquin

    2014-09-26

    Recent genomic projects have revealed the existence of an unexpectedly large amount of deleterious variability in the human genome. Several hypotheses have been proposed to explain such an apparently high mutational load. However, the mechanisms by which deleterious mutations in some genes cause a pathological effect but are apparently innocuous in other genes remain largely unknown. This study searched for deleterious variants in the 1,000 genomes populations, as well as in a newly sequenced population of 252 healthy Spanish individuals. In addition, variants causative of monogenic diseases and somatic variants from 41 chronic lymphocytic leukaemia patients were analysed. The deleterious variants found were analysed in the context of the interactome to understand the role of network topology in the maintenance of the observed mutational load. Our results suggest that one of the mechanisms whereby the effect of these deleterious variants on the phenotype is suppressed could be related to the configuration of the protein interaction network. Most of the deleterious variants observed in healthy individuals are concentrated in peripheral regions of the interactome, in combinations that preserve their connectivity, and have a marginal effect on interactome integrity. On the contrary, likely pathogenic cancer somatic deleterious variants tend to occur in internal regions of the interactome, often with associated structural consequences. Finally, variants causative of monogenic diseases seem to occupy an intermediate position. Our observations suggest that the real pathological potential of a variant might be more a systems property rather than an intrinsic property of individual proteins. © 2014 The Authors. Published under the terms of the CC BY 4.0 license.

  3. Structural impact analysis of missense SNPs present in the uroguanylin gene by long-term molecular dynamics simulations.

    PubMed

    Marcolino, Antonio C S; Porto, William F; Pires, Állan S; Franco, Octavio L; Alencar, Sérgio A

    2016-12-07

    The guanylate cyclase activator 2B, also known as uroguanylin, is part of the guanylin peptide family, which includes peptides such as guanylin and lymphoguanylin. The guanylin peptides could be related to sodium absorption inhibition and water secretion induction and their dysfunction may be related to various pathologies such as chronic renal failure, congestive heart failure and nephrotic syndrome. Besides, uroguanylin point mutations have been associated with essential hypertension. However, currently there are no studies on the impact of missense SNPs on uroguanylin structure. This study applied in silico SNP impact prediction tools to evaluate the impact of uroguanylin missense SNPs and to filter those considered as convergent deleterious, which were then further analyzed through long-term molecular dynamics simulations of 1μs of duration. The simulations suggested that all missense SNPs considered as convergent deleterious caused some kind of structural change to the uroguanylin peptide. Additionally, four of these SNPs were also shown to cause modifications in peptide flexibility, possibly resulting in functional changes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Evidence for Hitchhiking of Deleterious Mutations within the Human Genome

    PubMed Central

    Chun, Sung; Fay, Justin C.

    2011-01-01

    Deleterious mutations present a significant obstacle to adaptive evolution. Deleterious mutations can inhibit the spread of linked adaptive mutations through a population; conversely, adaptive substitutions can increase the frequency of linked deleterious mutations and even result in their fixation. To assess the impact of adaptive mutations on linked deleterious mutations, we examined the distribution of deleterious and neutral amino acid polymorphism in the human genome. Within genomic regions that show evidence of recent hitchhiking, we find fewer neutral but a similar number of deleterious SNPs compared to other genomic regions. The higher ratio of deleterious to neutral SNPs is consistent with simulated hitchhiking events and implies that positive selection eliminates some deleterious alleles and increases the frequency of others. The distribution of disease-associated alleles is also altered in hitchhiking regions. Disease alleles within hitchhiking regions have been associated with auto-immune disorders, metabolic diseases, cancers, and mental disorders. Our results suggest that positive selection has had a significant impact on deleterious polymorphism and may be partly responsible for the high frequency of certain human disease alleles. PMID:21901107

  5. Long-Term Results of a Phase II Trial of Ultrasound-Guided Radioactive Implantation of the Prostate for Definitive Management of Localized Adenocarcinoma of the Prostate (RTOG 98-05)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lawton, Colleen A., E-mail: clawton@mcw.edu; Hunt, Daniel; Lee, W. Robert

    2011-09-01

    Purpose: To evaluate the long-term effectiveness of transrectal ultrasound-guided permanent radioactive I{sup 125} implantation of the prostate for organ confined adenocarcinoma of the prostate compared with historical data of prostatectomy and external beam radiotherapy within a cooperative group setting. Methods and Materials: Patients accrued to this study had histologically confirmed, locally confined adenocarcinoma of the prostate clinical stage T1b, T1c, or T2a; no nodal or metastatic disease; prostate-specific antigen level of {<=}10 ng/ml; and a Gleason score of {<=}6. All patients underwent transrectal ultrasound-guided radioactive I{sup 125} seed implantation into the prostate. The prescribed dose was 145 Gy to themore » prostate planning target volume. Results: A total of 101 patients from 27 institutions were accrued to this protocol; by design, no single institution accrued more than 8 patients. There were 94 eligible patients. The median follow up was 8.1 years (range, 0.1-9.2 years). After 8 years, 8 patients had protocol-defined biochemical (prostate-specific antigen) failure (cumulative incidence, 8.0%); 5 patients had local failure (cumulative incidence, 5.5%); and 1 patient had distant failure (cumulative incidence, 1.1%; this patient also had biochemical failure and died of causes not related to prostate cancer). The 8-year overall survival rate was 88%. At last follow-up, no patient had died of prostate cancer or related toxicities. Three patients had maximum late toxicities of Grade 3, all of which were genitourinary. No Grade 4 or 5 toxicities were observed. Conclusions: The long-term results of this clinical trial have demonstrated that this kind of trial can be successfully completed through the RTOG and that results in terms of biochemical failure and toxicity compare very favorably with other brachytherapy published series as well as surgical and external beam radiotherapy series. In addition, the prospective, multicenter design

  6. Long-range effect of ion implantation of Raex and Hardox steels

    NASA Astrophysics Data System (ADS)

    Budzyński, P.; Kamiński, M.; Droździel, A.; Wiertel, M.

    2016-09-01

    Ion implantation involves introduction of ionized atoms of any element (nitrogen) to metals thanks to the high kinetic energy that they acquired in the electric field. The distribution of nitrogen ions implanted at E = 65 keV energy and D = 1.1017 N+ /cm2 fluence in the steel sample and vacancies produced by them was calculated using the SRIM program. This result was confirmed by RBS measurements. The initial maximum range of the implanted nitrogen ions is ∼⃒0.17 μm. This value is relatively small compared to the influence of nitriding on the thickness surface layer of modified steel piston rings. Measurements of the friction coefficient during the pin-on-disc tribological test were performed under dry friction conditions. The friction coefficient of the implanted sample increased to values characteristic of an unimplanted sample after ca. 1500 measurement cycles. The depth of wear trace is ca. 2.4 μm. This implies that the thickness of the layer modified by the implantation process is ∼⃒2.4 μm and exceeds the initial range of the implanted ions by an order of magnitude. This effect, referred to as a long-range implantation effect, is caused by migration of vacancies and nitrogen atoms into the sample. This phenomenon makes ion implantation a legitimate process of modification of the surface layer in order to enhance the tribological properties of critical components of internal combustion engines such as steel piston rings.

  7. Postmortem analysis of encapsulation around long-term ventricular endocardial pacing leads.

    PubMed

    Candinas, R; Duru, F; Schneider, J; Lüscher, T F; Stokes, K

    1999-02-01

    To analyze the site and thickness of encapsulation around ventricular endocardial pacing leads and the extent of tricuspid valve adhesion, from today's perspective, with implications for lead removal and sensor location. Gross cardiac postmortem analysis was performed in 11 cases (8 female and 3 male patients; mean age, 78+/-7 years). None of the patients had died because of pacemaker malfunction. The mean implant time was 61+/-60 months (range, 4 to 184). The observations ranged from encapsulation only at the tip of the pacing lead to complete encapsulation along the entire length of the pacing lead within the right ventricle. Substantial areas of adhesion at the tricuspid valve apparatus were noted in 7 of the 11 cases (64%). The firmly attached leads could be removed only by dissection, and in some cases, removal was possible only by damaging the associated structures. No specific optimal site for sensor placement could be identified along the ventricular portion of the pacing leads; however, the fibrotic response was relatively less prominent in the atrial chamber. Extensive encapsulation is present in most long-term pacemaker leads, which may complicate lead removal. The site and thickness of encapsulation seem to be highly variable. Tricuspid valve adhesion, which is usually underestimated, may be severe. In contrast to earlier reports, our study demonstrates that the extent of fibrotic encapsulation may not be related to the duration since lead implantation. Moreover, we noted no ideal encapsulation-free site for sensors on the ventricular portion of long-term pacing leads.

  8. The benefits of remote monitoring in long-term care for patients with implantable cardioverter-defibrillators.

    PubMed

    Ošmera, Ondřej; Bulava, Alan

    2014-01-01

    The increasing number of patients with implantable cardiac devices raises the need for more efficient outpatient follow-up care. Due to technological progress in communication and transmission systems and in the implantable devices themselves, telemonitoring can be widely used as an important part of care for patients and devices. Our objective was to evaluate the benefits of continuous remote monitoring using the BIOTRONIK Home Monitoring® (HM) system compared to standard outpatient follow-ups. 198 patients with single- or dual-chamber implantable cardioverter-defibrillator (ICD) implanted for primary or secondary prevention of sudden cardiac death were randomized into a group of patients followed through standard outpatient visits ( HM-) and a group telemonitored by the HM system (HM+). Planned and emergency visits, ICD-related hospitalizations, and delivered shocks and their appropriateness were evaluated in the respective groups. A significant reduction was achieved in the number of planned (by 48%, p<0.001) and total visits (by 45%, p<0.001) during a three-year evaluation. A comparable number of patients experienced one or more shocks. Mortality rates were equivalent, as was the number of patients hospitalized in relation to their ICD. However, there was a significant reduction in the number and proportion of inappropriate shocks delivered in the HM+ patient group: by 80% (p=0.002) in outpatient follow-up care and by 90% (p<0.001) when multiple shocks requiring hospitalization were included. The HM system was an effective and safe method of follow-up in patients with an implanted ICD. Remote monitoring reduces the number of outpatient visits and inappropriate shocks.

  9. Effect of aging and long-term erectile function after iodine-125 prostate brachytherapy.

    PubMed

    Keyes, Mira; Pickles, Tom; Crook, Juanita; McKenzie, Michael; Cheung, Arthur; Spadinger, Ingrid; LaPointe, Vincent; Bachand, W Francois; Morris, James

    2015-01-01

    To evaluate long-term erectile function (EF) in men treated with iodine-125 prostate brachytherapy (PB) and to determine factors predictive for erectile dysfunction (ED), including natural decline because of aging. Two thousand nine hundred twenty-nine patients (implanted July 1989-June 2012) with baseline EF and greater than 10-month followup (FU) are included. About 78.9% had full and 7.9% had partial EF at baseline. EF was assessed on a physician-reported three-point scale. Poisson regression with generalized estimating equations was used to assess predictors of ED and Kaplan-Meier curves time to ED. The effect of aging was calculated from the declining rate of baseline EF seen in sequential 5-year age cohorts and from the Massachusetts Male Aging Study. The median age was 66 years and median FU 3.5 years (maximum 14 years). About 1142 patients had more than 5 years of FU, and 43% had received 6 months of androgen deprivation therapy (ADT). Significant drop in EF was seen at 6 weeks after PB, with gradual decline thereafter. EF preservation at 5 years for age younger than 55, 56-59, 60-64, 65-69, and 70 year and older was 82%, 73%, 58%, 39%, and 23%, respectively. Comparisons of the 5-year age-related and treatment-related EF decline show that 50% of the long-term EF decline is related to aging. On univariate and multivariate analyses, age at implant, length of FU, hypertension, diabetes, and use of ADT (all p < 0.01) were significant predictors of ED. More than 80% of young men have EF preserved 5 years after PB. Age, ADT, history of hypertension, and the natural decline in EF have negative impact on long-term EF after PB. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.

  10. Short Implants: New Horizon in Implant Dentistry.

    PubMed

    Jain, Neha; Gulati, Manisha; Garg, Meenu; Pathak, Chetan

    2016-09-01

    The choice of implant length is an essential factor in deciding the survival rates of these implants and the overall success of the prosthesis. Placing an implant in the posterior part of the maxilla and mandible has always been very critical due to poor bone quality and quantity. Long implants can be placed in association with complex surgical procedures such as sinus lift and bone augmentation. These techniques are associated with higher cost, increased treatment time and greater morbidity. Hence, there is need for a less invasive treatment option in areas of poor bone quantity and quality. Data related to survival rates of short implants, their design and prosthetic considerations has been compiled and structured in this manuscript with emphasis on the indications, advantages of short implants and critical biomechanical factors to be taken into consideration when choosing to place them. Studies have shown that comparable success rates can be achieved with short implants as those with long implants by decreasing the lateral forces to the prosthesis, eliminating cantilevers, increasing implant surface area and improving implant to abutment connection. Short implants can be considered as an effective treatment alternative in resorbed ridges. Short implants can be considered as a viable treatment option in atrophic ridge cases in order to avoid complex surgical procedures required to place long implants. With improvement in the implant surface geometry and surface texture, there is an increase in the bone implant contact area which provides a good primary stability during osseo-integration.

  11. Long-term outcomes of phakic patients with diabetic macular oedema treated with intravitreal fluocinolone acetonide (FAc) implants.

    PubMed

    Yang, Y; Bailey, C; Holz, F G; Eter, N; Weber, M; Baker, C; Kiss, S; Menchini, U; Ruiz Moreno, J M; Dugel, P; Lotery, A

    2015-09-01

    Diabetic macular oedema (DMO) is a leading cause of blindness in working-age adults. Slow-release, nonbioerodible fluocinolone acetonide (FAc) implants have shown efficacy in the treatment of DMO; however, the National Institute for Health and Care Excellence recommends that FAc should be used in patients with chronic DMO considered insufficiently responsive to other available therapies only if the eye to be treated is pseudophakic. The goal of this analysis was to examine treatment outcomes in phakic patients who received 0.2 μg/day FAc implant. This analysis of the phase 3 FAME (Fluocinolone Acetonide in Diabetic Macular Edema) data examines the safety and efficacy of FAc implants in patients who underwent cataract extraction before (cataract before implant (CBI) group) or after (cataract after implant (CAI) group) receiving the implant. The data were further examined by DMO duration. Best corrected visual acuity (BCVA) after 36 months was comparable in the CAI and CBI groups. Both the percentage of patients gaining ≥ 3 lines of vision and mean change in BCVA letter score were numerically greater in the CAI group. In addition, most patients who underwent cataract surgery experienced a net gain in BCVA from presurgery baseline as well as from original study baseline. These data support the use of 0.2 μg/day FAc implants in phakic as well as in pseudophakic patients. These findings will serve as a pilot for design of future studies to evaluate the potential protective effect of FAc implants before cataract surgery in patients with DMO and cataract.

  12. Long-term outcomes of phakic patients with diabetic macular oedema treated with intravitreal fluocinolone acetonide (FAc) implants

    PubMed Central

    Yang, Y; Bailey, C; Holz, F G; Eter, N; Weber, M; Baker, C; Kiss, S; Menchini, U; Ruiz Moreno, J M; Dugel, P; Lotery, A

    2015-01-01

    Purpose Diabetic macular oedema (DMO) is a leading cause of blindness in working-age adults. Slow-release, nonbioerodible fluocinolone acetonide (FAc) implants have shown efficacy in the treatment of DMO; however, the National Institute for Health and Care Excellence recommends that FAc should be used in patients with chronic DMO considered insufficiently responsive to other available therapies only if the eye to be treated is pseudophakic. The goal of this analysis was to examine treatment outcomes in phakic patients who received 0.2 μg/day FAc implant. Methods This analysis of the phase 3 FAME (Fluocinolone Acetonide in Diabetic Macular Edema) data examines the safety and efficacy of FAc implants in patients who underwent cataract extraction before (cataract before implant (CBI) group) or after (cataract after implant (CAI) group) receiving the implant. The data were further examined by DMO duration. Results Best corrected visual acuity (BCVA) after 36 months was comparable in the CAI and CBI groups. Both the percentage of patients gaining ≥3 lines of vision and mean change in BCVA letter score were numerically greater in the CAI group. In addition, most patients who underwent cataract surgery experienced a net gain in BCVA from presurgery baseline as well as from original study baseline. Conclusions These data support the use of 0.2 μg/day FAc implants in phakic as well as in pseudophakic patients. These findings will serve as a pilot for design of future studies to evaluate the potential protective effect of FAc implants before cataract surgery in patients with DMO and cataract. PMID:26113503

  13. Design of a long-term antipsychotic in situ forming implant and its release control method and mechanism.

    PubMed

    Wang, Lexi; Wang, Aiping; Zhao, Xiaolei; Liu, Ximing; Wang, Dan; Sun, Fengying; Li, Youxin

    2012-05-10

    Two kinds of in situ forming implants (ISFIs) of atypical antipsychotics, risperidone and its 9-hydroxy active metabolite, paliperidone, using poly(lactide-co-glycolide)(PLGA) as carrier, were investigated. Significant difference was observed in the solution-gel transition mechanism of the two systems: homogeneous system of N-methyl-2-pyrrolidone (NMP) ISFI, in which drug was dissolved, and heterogeneous system of dimethyl sulfoxide (DMSO) ISFI, in which drug was dispersed. Fast solvent extractions were found in both systems, but in comparison with the high drug release rate from homogeneous system of drug/polymer/NMP, a fast solvent extraction from the heterogeneous system of drug/polymer/DMSO was not accompanied by a high drug release rate but a rapid solidification of the implant, which resulted in a high drug retention, well-controlled initial burst and slow release of the drug. In vivo study on beagle dogs showed a more than 3-week sustained release with limited initial burst. Pharmacologic evaluation on optimized paliperidone ISFIs presented a sustained-suppressing effect from 1 day to 38 day on the MK-801 induced schizophrenic behavior mice model. A long sustained-release antipsychotic ISFI of 50% drug loading and controlled burst release was achieved, which indicated a good potential in clinic application. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. A retrospective analysis of the risk factors for surgical site infections and long-term follow-up after transpalpebral enucleation in horses.

    PubMed

    Huppes, Tsjester; Hermans, Hanneke; Ensink, Jos M

    2017-06-02

    Implants are often used to improve the cosmetic appearance of horses after enucleation of the eye. When surgical site infection (SSI) occurs, the implant will almost always be lost. The aim of this study is to collect data on the risk factors for SSIs and report long-term follow-up (cosmetic results and return to work) after transpalpebral enucleations. In this retrospective study, records of horses undergoing transpalpebral enucleation were reviewed (2007-2014) and telephone interviews were used to obtain long term follow-up. The potential risk factors for SSIs (indication for enucleation, use of an implant, standing procedures, duration of surgery, opening of the conjunctival sac and prolonged use of antimicrobials) were analysed for their association with the outcome measure 'SSI' vs 'no SSI' by multivariable binary logistic regression testing. Indications for enucleation were grouped as follows: Group 1 (clean) included equine recurrent uveitis, too small or too large globes, and intraocular tumours, Group 2 (non-clean) included corneal perforation/rupture and infected ulcers and Group 3 (tumour) included extraocular tumours. One hundred and seven cases of enucleation were evaluated. An implant was used in 49 horses. The overall number of SSIs was 8 (7.5%). Multivariable logistic regression testing showed implants (OR 7.5, P = 0.04) and standing procedures (OR 12.1; P = 0.03) were significantly associated with the percentage of SSIs and increased the risk of SSI. The eyes of horses in Groups 2 and 3 trended towards a larger risk for developing SSIs (OR 4.9; P = 0.09 and OR 5.9; P = 0.1, respectively). Prolonged use of antimicrobials, long surgery times and the opening of the conjunctival sac during dissection did not show significant associations with SSI risk. The risk of SSI after enucleation is low in clean eyes and when no implant is used. Placing an implant or performing a standing enucleation significantly increases the risk of SSIs. Although

  15. Evaluation of the peri-implant bone around parallel-walled dental implants with a condensing thread macrodesign and a self-tapping apex: a 10-year retrospective histological analysis.

    PubMed

    Degidi, Marco; Perrotti, Vittoria; Shibli, Jamil A; Mortellaro, Carmen; Piattelli, Adriano; Iezzi, Giovanna

    2014-05-01

    The long-term high percentages of survival and success of dental implants reported in the literature are related mainly to new, innovative implant and thread designs, and new implant surfaces that allow to obtain very good primary and secondary stability in most anatomical and clinical situations, even in low quality and quantity of bone, promoting a more rapid osseointegration. The aim of this retrospective study was a histological and histomorphometrical evaluation of the bone response around implants with a parallel-wall configuration, condensing thread macrodesign, and self-tapping apex, retrieved from man for different causes. A total of 10 implants were reported in the present study, and these implants had been retrieved after a loading period comprised between a few weeks to about 8 years. Mineralized newly formed bone was found at the interface of all the implants, in direct contact with the implant surface, with no gaps or connective fibrous tissue. This bone adapted very well to the microirregularities of the implant surface. Areas of bone remodeling were present in some regions of the interface, with many reversal lines. High bone-implant contact percentages were found. In conclusion, both the macrostructure and the microstructure of this specific type of implant could be very helpful in the long-term high survival and success implant percentages.

  16. The effects of implant angulation on the resonance frequency of a dental implant.

    PubMed

    Harirforoush, R; Arzanpour, S; Chehroudi, B

    2014-08-01

    Dental implants are ideally placed in an orientation that allows vertical transfer of occlusal forces along their long axis. Nevertheless, optimal situations for implant placement are seldom encountered resulting in implants placement in angulated positions, which may affect their long-term success. The resonance frequency (RF) is an objective tool used to monitor stability of the implant tissue integration; however, little is known of the effect of the implant orientation in bone on the RF and its potential significance. The purpose of this research was to determine the relation between the dental implant orientation and the corresponding RF of implant. Three-dimensional (3D) modelling software was used to construct a 3D model of a pig mandible from computed tomography (CT) images. The RF of the implant was analysed using finite element (FE) modal analysis in software ANSYS (v.12). In addition, a cubical model was also developed in MIMICS to investigate the parameters affecting the relationship between RF and implant orientation in a simplified environment. The orientation angle was increased from 0 to 10 degrees in 1 degree increments and the resulting RF was analysed using correlation analysis and one-way ANOVA. Our analysis illustrated that the RF fluctuation following altering implant orientation was strongly correlated (r=0.97) with the contacting cortical to cancellous bone ratio (CCBR) at the implant interface. The most extreme RF change (from 9.81kHz to 10.07kHz) occurred when the implant was moved 0.5mm in positive z-direction, which resulted in the maximum change of CCBR from 52.9 to 54.8. Copyright © 2014. Published by Elsevier Ltd.

  17. Dual- vs. single-chamber defibrillators for primary prevention of sudden cardiac death: long-term follow-up of the Défibrillateur Automatique Implantable-Prévention Primaire registry.

    PubMed

    Defaye, Pascal; Boveda, Serge; Klug, Didier; Beganton, Frankie; Piot, Olivier; Narayanan, Kumar; Périer, Marie-Cécile; Gras, Daniel; Fauchier, Laurent; Bordachar, Pierre; Algalarrondo, Vincent; Babuty, Dominique; Deharo, Jean-Claude; Leclercq, Christophe; Marijon, Eloi; Sadoul, Nicolas

    2017-09-01

    Implantable cardioverter defibrillators (ICDs) are an effective primary prevention of sudden cardiac death. We examined whether dual-chamber (DC) ICDs confer a greater benefit than single-chamber (SC) ICDs, and compared the long-term outcomes of recipients of each type of device implanted for primary prevention. Between 2002 and 2012, the DAI-PP registry consecutively enrolled 1258 SC- and 1280 DC-ICD recipients at 12 French medical centres. The devices were interrogated at 4- to 6-month intervals during outpatient visits, with a focus on the therapies delivered. The study endpoints were incidence of appropriate therapies, ICD-related morbidity, and deaths from all and from specific causes. The mean age of the SC- and DC-ICD recipients was 59 ± 12 and 62 ± 11 years, respectively (P< 0.0001). The distribution of genders, New York Heart Association functional classes and glomerular filtration rates, and the rates of ischaemic vs. dilated cardiomyopathies and of defibrillation tests at implant, were similar in both study groups. The rates of periprocedural complications were 12.1% in the DC- vs. 8.8% in the SC-ICD groups (P= 0.008). Over a mean follow-up of 3.1 ± 2.2 years, pulse generators were replaced in 21.9% of the DC- vs. 13.6% of the SC-ICD group (P< 0.0001). The proportions of patients treated with ≥1 appropriate therapies (24.7 vs. 23.8%) and ≥1 inappropriate shocks (8.4 vs. 7.8%), and all-cause mortality (12.4 vs. 13.2%) were similar in both groups. In this large registry of ICD implanted for primary prevention, DC-ICDs were associated with higher rates of peri-implant complications and generator replacements, whereas the survival and rates of inappropriate shocks were similar in both groups. NCT#01992458. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions please email: journals.permissions@oup.com.

  18. Energy harvesting by implantable abiotically catalyzed glucose fuel cells

    NASA Astrophysics Data System (ADS)

    Kerzenmacher, S.; Ducrée, J.; Zengerle, R.; von Stetten, F.

    Implantable glucose fuel cells are a promising approach to realize an autonomous energy supply for medical implants that solely relies on the electrochemical reaction of oxygen and glucose. Key advantage over conventional batteries is the abundant availability of both reactants in body fluids, rendering the need for regular replacement or external recharging mechanisms obsolete. Implantable glucose fuel cells, based on abiotic catalysts such as noble metals and activated carbon, have already been developed as power supply for cardiac pacemakers in the late-1960s. Whereas, in vitro and preliminary in vivo studies demonstrated their long-term stability, the performance of these fuel cells is limited to the μW-range. Consequently, no further developments have been reported since high-capacity lithium iodine batteries for cardiac pacemakers became available in the mid-1970s. In recent years research has been focused on enzymatically catalyzed glucose fuel cells. They offer higher power densities than their abiotically catalyzed counterparts, but the limited enzyme stability impedes long-term application. In this context, the trend towards increasingly energy-efficient low power MEMS (micro-electro-mechanical systems) implants has revived the interest in abiotic catalysts as a long-term stable alternative. This review covers the state-of-the-art in implantable abiotically catalyzed glucose fuel cells and their development since the 1960s. Different embodiment concepts are presented and the historical achievements of academic and industrial research groups are critically reviewed. Special regard is given to the applicability of the concept as sustainable micro-power generator for implantable devices.

  19. Long-Term Comparison of Posterior Chamber Phakic Intraocular Lens With and Without a Central Hole (Hole ICL and Conventional ICL) Implantation for Moderate to High Myopia and Myopic Astigmatism: Consort-Compliant Article.

    PubMed

    Shimizu, Kimiya; Kamiya, Kazutaka; Igarashi, Akihito; Kobashi, Hidenaga

    2016-04-01

    The study shows a promising next-generation surgical option for the correction of moderate to high ametropia. Hole implantable collamer lens (ICL), STAAR Surgical, is a posterior chamber phakic intraocular lens with a central artificial hole. As yet, however, no long-term comparison of the clinical results of the implantation of ICLs with and without such a hole has hitherto been conducted. A prospective, randomized, controlled trial was carried out in order to compare the long-term clinical outcomes of the implantation, in such eyes, of ICLs with and without a central artificial hole.Examinations were conducted of the 64 eyes of 32 consecutive patients with spherical equivalents of -7.53 ± 2.39 diopters (D) (mean ± standard deviation) in whom implantation of a Hole ICL was performed in 1 eye, and that of a conventional ICL was carried out in the other, by randomized assignment. Before 1, 3, and 6 months, and 1, 3, and 5 years after surgery, the safety, efficacy, predictability, stability, intraocular pressure, endothelial cell density, and adverse events of the 2 surgical techniques were assessed and compared over time.The measurements of LogMAR uncorrected and corrected distance visual acuity 5 years postoperatively were -0.17 ± 0.14 and -0.24 ± 0.08 in the Hole ICL group, and -0.16 ± 0.10 and -0.25 ± 0.08 in the conventional ICL group. In these 2 groups, 96% and 100% of eyes, respectively, were within 1.0 D of the targeted correction 5 years postoperatively. Manifest refraction changed by -0.17 ± 0.41 D and -0.10 ± 0.26 D occurred in from 1 month to 5 years in the Hole and conventional ICL groups, respectively. Only 1 eye (3.1%), which was in the conventional ICL group, developed an asymptomatic anterior subcapsular cataract.Both Hole and conventional ICLs corrected of ametropia successfully throughout the 5-year observation period. It appears likely that the presence of the central hole does not significantly affect these

  20. Long-term cumulative survival and mechanical complications of single-tooth Ankylos Implants: focus on the abutment neck fractures.

    PubMed

    Shim, Hye Won; Yang, Byoung-Eun

    2015-12-01

    To evaluate the cumulative survival rate (CSR) and mechanical complications of single-tooth Ankylos® implants. This was a retrospective clinical study that analyzed 450 single Ankylos® implants installed in 275 patients between December 2005 and December 2012. The main outcomes were survival results CSR and implant failure) and mechanical complications (screw loosening, fracture, and cumulative fracture rate [CFR]). The main outcomes were analyzed according to age, sex, implant length or diameter, bone graft, arch, and position. The 8-year CSR was 96.9%. Thirteen (2.9%) implants failed because of early osseointegration failure in 3, marginal bone loss in 6, and abutment fracture in 4. Screw loosening occurred in 10 implants (2.2%), and 10 abutment fractures occurred. All abutment fractures were located in the neck, and concurrent screw fractures were observed. The CSR and rate of screw loosening did not differ significantly according to factors. The CFR was higher in middle-aged patients (5.3% vs 0.0% in younger and older patients); for teeth in a molar position (5.8% vs 0.0% for premolar or 1.1% for anterior position); and for larger-diameter implants (4.5% for 4.5 mm and 6.7% for 5.5 mm diameter vs 0.5% for 3.5 mm diameter) (all P<.05). The Ankylos® implant is suitable for single-tooth restoration in Koreans. However, relatively frequent abutment fractures (2.2%) were observed and some fractures resulted in implant failures. Middle-aged patients, the molar position, and a large implant diameter were associated with a high incidence of abutment fracture.

  1. Near-Term Actions to Address Long-Term Climate Risk

    NASA Astrophysics Data System (ADS)

    Lempert, R. J.

    2014-12-01

    Addressing climate change requires effective long-term policy making, which occurs when reflecting on potential events decades or more in the future causes policy makers to choose near-term actions different than those they would otherwise pursue. Contrary to some expectations, policy makers do sometimes make such long-term decisions, but not as commonly and successfully as climate change may require. In recent years however, the new capabilities of analytic decision support tools, combined with improved understanding of cognitive and organizational behaviors, has significantly improved the methods available for organizations to manage longer-term climate risks. In particular, these tools allow decision makers to understand what near-term actions consistently contribute to achieving both short- and long-term societal goals, even in the face of deep uncertainty regarding the long-term future. This talk will describe applications of these approaches for infrastructure, water, and flood risk management planning, as well as studies of how near-term choices about policy architectures can affect long-term greenhouse gas emission reduction pathways.

  2. Group D. Initiator paper. Implants--peri-implant (hard and soft tissue) interactions in health and disease: the impact of explosion of implant manufacturers.

    PubMed

    Ivanovski, Saso

    2015-01-01

    1. The best-documented implants have a threaded solid screw-type design and are manufactured from commercially pure (grade IV) titanium. There is good evidence to support implants ≥ 6 mm in length, and ≥ 3 mm in diameter. 2. Integrity of the seal between the abutment and the implant is important for several reasons, including minimization of mechanical and biological complications and maintaining marginal bone levels. Although the ideal design features of the implant-abutment connection have not been determined, an internal connection, micro-grooves at the implant collar, and horizontal offset of the implant-abutment junction (platform switch) appear to impart favorable properties. 3. Implants with moderately rough implant surfaces provide advantages over machined surfaces in terms of the speed and extent of osseointegration. While the favorable performances of both minimally and moderately rough surfaces are supported by long-term data, moderately rough surfaces provide superior outcomes in compromised sites, such as the posterior maxilla. 4. Although plaque is critical in the progression of peri-implantitis, the disease has a multi-factorial aetiology, and may be influenced by poor integrity of the abutment/implant connection. Iatrogenic factors, such as the introduction of a foreign body. (e.g., cement) below the mucosal margin, can be important contributors. 5. Clinicians should exercise caution when using a particular implant system, ensuring that the implant design is appropriate and supported by scientific evidence. Central to this is access to and participation in quality education on the impact that implant characteristics can have on clinical outcomes. Caution should be exercised in utilizing non-genuine restorative componentry that may lead to a poor implant-abutment fit and subsequent technical and biological complications.

  3. Duration of Sexual Harassment and Generalized Harassment in the Workplace Over Ten Years: Effects on Deleterious Drinking Outcomes

    PubMed Central

    McGinley, Meredith; Richman, Judith A.; Rospenda, Kathleen M.

    2012-01-01

    While harassment in the workplace has been linked to deleterious drinking outcomes, researchers have yet to examine the long-term effects of chronic workplace harassment. During a ten year longitudinal mail survey, university employees (N = 2265) were administered measures of sexual harassment, generalized workplace harassment, and problematic drinking. Using growth mixture modeling, two latent classes of workplace harassment emerged: infrequent and chronic. Demographic characteristics (gender, age, and race) predicted the shape of the trajectories and likelihood of class membership. As hypothesized, membership in the chronic harassment classes was linked to future problematic drinking, even after controlling for previous drinking. PMID:21745045

  4. Duration of sexual harassment and generalized harassment in the workplace over ten years: effects on deleterious drinking outcomes.

    PubMed

    McGinley, Meredith; Richman, Judith A; Rospenda, Kathleen M

    2011-01-01

    Although harassment in the workplace has been linked to deleterious drinking outcomes, researchers have yet to examine the long-term effects of chronic workplace harassment. During a 10-year longitudinal mail survey, university employees (N = 2,265) were administered measures of sexual harassment, generalized workplace harassment, and problematic drinking. Using growth mixture modeling, two latent classes of workplace harassment emerged: infrequent and chronic. Demographic characteristics (gender, age, and race) predicted the shape of the trajectories and likelihood of class membership. As hypothesized, membership in the chronic harassment classes was linked to future problematic drinking, even after controlling for previous drinking.

  5. Short Implants: New Horizon in Implant Dentistry

    PubMed Central

    Gulati, Manisha; Garg, Meenu; Pathak, Chetan

    2016-01-01

    The choice of implant length is an essential factor in deciding the survival rates of these implants and the overall success of the prosthesis. Placing an implant in the posterior part of the maxilla and mandible has always been very critical due to poor bone quality and quantity. Long implants can be placed in association with complex surgical procedures such as sinus lift and bone augmentation. These techniques are associated with higher cost, increased treatment time and greater morbidity. Hence, there is need for a less invasive treatment option in areas of poor bone quantity and quality. Data related to survival rates of short implants, their design and prosthetic considerations has been compiled and structured in this manuscript with emphasis on the indications, advantages of short implants and critical biomechanical factors to be taken into consideration when choosing to place them. Studies have shown that comparable success rates can be achieved with short implants as those with long implants by decreasing the lateral forces to the prosthesis, eliminating cantilevers, increasing implant surface area and improving implant to abutment connection. Short implants can be considered as an effective treatment alternative in resorbed ridges. Short implants can be considered as a viable treatment option in atrophic ridge cases in order to avoid complex surgical procedures required to place long implants. With improvement in the implant surface geometry and surface texture, there is an increase in the bone implant contact area which provides a good primary stability during osseo-integration. PMID:27790598

  6. Cannabis and first-episode psychosis: different long-term outcomes depending on continued or discontinued use.

    PubMed

    González-Pinto, Ana; Alberich, Susana; Barbeito, Sara; Gutierrez, Miguel; Vega, Patricia; Ibáñez, Berta; Haidar, Mahmoud Karim; Vieta, Eduard; Arango, Celso

    2011-05-01

    To examine the influence of cannabis use on long-term outcome in patients with a first psychotic episode, comparing patients who have never used cannabis with (a) those who used cannabis before the first episode but stopped using it during follow-up and (b) those who used cannabis both before the first episode and during follow-up. Patients were studied following their first admission for psychosis. They were interviewed at years 1, 3, and 5. At follow-up after 8 years, functional outcome and alcohol and drug abuse were recorded. Patients were classified according to cannabis use: 25 had cannabis use before their first psychotic episode and continuous use during follow-up (CU), 27 had cannabis use before their first episode but stopped its use during follow-up (CUS), and 40 never used cannabis (NU). The 3 groups did not differ significantly in symptoms or functional outcome at baseline or during short-term follow-up. The CUS group exhibited better long-term functional outcome compared with the other 2 groups and had fewer negative symptoms than the CU group, after adjusting for potential confounders. For the CUS group, the effect size was 1.26 (95% confidence interval [CI]=0.65 to 1.86) for functional outcome and -0.72 (95% CI=-1.27 to -0.14) for negative symptoms. All patients experienced improvements in positive symptoms during long-term follow-up. Cannabis has a deleterious effect, but stopping use after the first psychotic episode contributes to a clear improvement in outcome. The positive effects of stopping cannabis use can be seen more clearly in the long term. © The Author 2009. Published by Oxford University Press on behalf of the Maryland Psychiatric Research Center.

  7. Ketamine alters cortical integration of GABAergic interneurons and induces long-term sex-dependent impairments in transgenic Gad67-GFP mice.

    PubMed

    Aligny, C; Roux, C; Dourmap, N; Ramdani, Y; Do-Rego, J-C; Jégou, S; Leroux, P; Leroux-Nicollet, I; Marret, S; Gonzalez, B J

    2014-07-03

    Ketamine, a non-competitive N-methyl-D-aspartate (NMDA) antagonist, widely used as an anesthetic in neonatal pediatrics, is also an illicit drug named Super K or KitKat consumed by teens and young adults. In the immature brain, despite several studies indicating that NMDA antagonists are neuroprotective against excitotoxic injuries, there is more and more evidence indicating that these molecules exert a deleterious effect by suppressing a trophic function of glutamate. In the present study, we show using Gad67-GFP mice that prenatal exposure to ketamine during a time-window in which GABAergic precursors are migrating results in (i) strong apoptotic death in the ganglionic eminences and along the migratory routes of GABAergic interneurons; (ii) long-term deficits in interneuron density, dendrite numbers and spine morphology; (iii) a sex-dependent deregulation of γ-aminobutyric acid (GABA) levels and GABA transporter expression; (iv) sex-dependent changes in the response to glutamate-induced calcium mobilization; and (v) the long-term sex-dependent behavioral impairment of locomotor activity. In conclusion, using a preclinical approach, the present study shows that ketamine exposure during cortical maturation durably affects the integration of GABAergic interneurons by reducing their survival and differentiation. The resulting molecular, morphological and functional modifications are associated with sex-specific behavioral deficits in adults. In light of the present data, it appears that in humans, ketamine could be deleterious for the development of the brain of preterm neonates and fetuses of addicted pregnant women.

  8. Long-term cumulative survival and mechanical complications of single-tooth Ankylos Implants: focus on the abutment neck fractures

    PubMed Central

    2015-01-01

    PURPOSE To evaluate the cumulative survival rate (CSR) and mechanical complications of single-tooth Ankylos® implants. MATERIALS AND METHODS This was a retrospective clinical study that analyzed 450 single Ankylos® implants installed in 275 patients between December 2005 and December 2012. The main outcomes were survival results CSR and implant failure) and mechanical complications (screw loosening, fracture, and cumulative fracture rate [CFR]). The main outcomes were analyzed according to age, sex, implant length or diameter, bone graft, arch, and position. RESULTS The 8-year CSR was 96.9%. Thirteen (2.9%) implants failed because of early osseointegration failure in 3, marginal bone loss in 6, and abutment fracture in 4. Screw loosening occurred in 10 implants (2.2%), and 10 abutment fractures occurred. All abutment fractures were located in the neck, and concurrent screw fractures were observed. The CSR and rate of screw loosening did not differ significantly according to factors. The CFR was higher in middle-aged patients (5.3% vs 0.0% in younger and older patients); for teeth in a molar position (5.8% vs 0.0% for premolar or 1.1% for anterior position); and for larger-diameter implants (4.5% for 4.5 mm and 6.7% for 5.5 mm diameter vs 0.5% for 3.5 mm diameter) (all P<.05). CONCLUSION The Ankylos® implant is suitable for single-tooth restoration in Koreans. However, relatively frequent abutment fractures (2.2%) were observed and some fractures resulted in implant failures. Middle-aged patients, the molar position, and a large implant diameter were associated with a high incidence of abutment fracture. PMID:26813443

  9. Benefits and Risks of Cochlear Implants

    MedlinePlus

    ... The cochlear implant stimulates the nerves directly with electrical currents. Although this stimulation appears to be safe, the long term effect of these electrical currents on the nerves is unknown. May not ...

  10. Use of autologous human mesenchymal stromal cell/fibrin clot constructs in upper limb non-unions: long-term assessment.

    PubMed

    Giannotti, Stefano; Trombi, Luisa; Bottai, Vanna; Ghilardi, Marco; D'Alessandro, Delfo; Danti, Serena; Dell'Osso, Giacomo; Guido, Giulio; Petrini, Mario

    2013-01-01

    Tissue engineering appears to be an attractive alternative to the traditional approach in the treatment of fracture non-unions. Mesenchymal stromal cells (MSCs) are considered an appealing cell source for clinical intervention. However, ex vivo cell expansion and differentiation towards the osteogenic lineage, together with the design of a suitable scaffold have yet to be optimized. Major concerns exist about the safety of MSC-based therapies, including possible abnormal overgrowth and potential cancer evolution. We examined the long-term efficacy and safety of ex vivo expanded bone marrow MSCs, embedded in autologous fibrin clots, for the healing of atrophic pseudarthrosis of the upper limb. Our research work relied on three main issues: use of an entirely autologous context (cells, serum for ex vivo cell culture, scaffold components), reduced ex vivo cell expansion, and short-term MSC osteoinduction before implantation. Bone marrow MSCs isolated from 8 patients were expanded ex vivo until passage 1 and short-term osteo-differentiated in autologous-based culture conditions. Tissue-engineered constructs designed to embed MSCs in autologous fibrin clots were locally implanted with bone grafts, calibrating their number on the extension of bone damage. Radiographic healing was evaluated with short- and long-term follow-ups (range averages: 6.7 and 76.0 months, respectively). All patients recovered limb function, with no evidence of tissue overgrowth or tumor formation. Our study indicates that highly autologous treatment can be effective and safe in the long-term healing of bone non-unions. This tissue engineering approach resulted in successful clinical and functional outcomes for all patients.

  11. Interaction of Vasopressin and Splenda on Glucose Metabolism and Long-term Preferences under Ad-libitum and Food-restricted Conditions.

    PubMed

    Murphy, H M; Wideman, C H; Cleary, A M

    1999-01-01

    Previous research has demonstrated that vasopressin-containing rats are capable of adapting to the stress of food restriction; whereas, vasopressin-deficient rats cannot adapt to this stressor. In the present study, the value of using a low-calorie (Splenda) or no-calorie (Equal) artificial sweetener to reverse the deleterious effects of food restriction in vasopressin-deficient rats was examined. In association with this effect, the role of vasopressin in long-term preferences for the two artificial sweeteners was studied. Vasopressin-deficient, Brattleboro (DI) rats and vasopressin-containing, Long-Evans (LE) rats underwent an habituation phase during which they had ad-libitum access to food. This was followed by an experimental phase during which the rats were divided into four groups. (1) DI rats continued with ad-libitum feeding, (2) LE rats continued with ad-libitum feeding, (3) DI rats subjected to 23 h of food restriction, and (4) LE rats subjected to 23 h of food restriction. All rats had ad-libitum access to an 8% Splenda solution, a 1% Equal solution, and water throughout both phases of the experiment. The deleterious effects of food restriction were completely reversed in DI rats, including survival, no stomach pathology, and normal plasma levels of glucose and urea nitrogen.

  12. Long term stability of nanowire nanoelectronics in physiological environments.

    PubMed

    Zhou, Wei; Dai, Xiaochuan; Fu, Tian-Ming; Xie, Chong; Liu, Jia; Lieber, Charles M

    2014-03-12

    Nanowire nanoelectronic devices have been exploited as highly sensitive subcellular resolution detectors for recording extracellular and intracellular signals from cells, as well as from natural and engineered/cyborg tissues, and in this capacity open many opportunities for fundamental biological research and biomedical applications. Here we demonstrate the capability to take full advantage of the attractive capabilities of nanowire nanoelectronic devices for long term physiological studies by passivating the nanowire elements with ultrathin metal oxide shells. Studies of Si and Si/aluminum oxide (Al2O3) core/shell nanowires in physiological solutions at 37 °C demonstrate long-term stability extending for at least 100 days in samples coated with 10 nm thick Al2O3 shells. In addition, investigations of nanowires configured as field-effect transistors (FETs) demonstrate that the Si/Al2O3 core/shell nanowire FETs exhibit good device performance for at least 4 months in physiological model solutions at 37 °C. The generality of this approach was also tested with in studies of Ge/Si and InAs nanowires, where Ge/Si/Al2O3 and InAs/Al2O3 core/shell materials exhibited stability for at least 100 days in physiological model solutions at 37 °C. In addition, investigations of hafnium oxide-Al2O3 nanolaminated shells indicate the potential to extend nanowire stability well beyond 1 year time scale in vivo. These studies demonstrate that straightforward core/shell nanowire nanoelectronic devices can exhibit the long term stability needed for a range of chronic in vivo studies in animals as well as powerful biomedical implants that could improve monitoring and treatment of disease.

  13. Long Term Stability of Nanowire Nanoelectronics in Physiological Environments

    PubMed Central

    2015-01-01

    Nanowire nanoelectronic devices have been exploited as highly sensitive subcellular resolution detectors for recording extracellular and intracellular signals from cells, as well as from natural and engineered/cyborg tissues, and in this capacity open many opportunities for fundamental biological research and biomedical applications. Here we demonstrate the capability to take full advantage of the attractive capabilities of nanowire nanoelectronic devices for long term physiological studies by passivating the nanowire elements with ultrathin metal oxide shells. Studies of Si and Si/aluminum oxide (Al2O3) core/shell nanowires in physiological solutions at 37 °C demonstrate long-term stability extending for at least 100 days in samples coated with 10 nm thick Al2O3 shells. In addition, investigations of nanowires configured as field-effect transistors (FETs) demonstrate that the Si/Al2O3 core/shell nanowire FETs exhibit good device performance for at least 4 months in physiological model solutions at 37 °C. The generality of this approach was also tested with in studies of Ge/Si and InAs nanowires, where Ge/Si/Al2O3 and InAs/Al2O3 core/shell materials exhibited stability for at least 100 days in physiological model solutions at 37 °C. In addition, investigations of hafnium oxide-Al2O3 nanolaminated shells indicate the potential to extend nanowire stability well beyond 1 year time scale in vivo. These studies demonstrate that straightforward core/shell nanowire nanoelectronic devices can exhibit the long term stability needed for a range of chronic in vivo studies in animals as well as powerful biomedical implants that could improve monitoring and treatment of disease. PMID:24479700

  14. In Vivo Validation of Custom-Designed Silicon-Based Microelectrode Arrays for Long-Term Neural Recording and Stimulation

    PubMed Central

    Manoonkitiwongsa, Panya S.; Wang, Cindy X.; McCreery, Douglas B.

    2012-01-01

    We developed and validated silicon-based neural probes for neural stimulating and recording in long-term implantation in the brain. The probes combine the deep reactive ion etching process and mechanical shaping of their tip region, yielding a mechanically sturdy shank with a sharpened tip to reduce insertion force into the brain and spinal cord, particularly, with multiple shanks in the same array. The arrays’ insertion forces have been quantified in vitro. Five consecutive chronically-implanted devices were fully functional from 3 to 18 months. The microelectrode sites were electroplated with iridium oxide, and the charge injection capacity measurements were performed both in vitro and after implantation in the adult feline brain. The functionality of the chronic array was validated by stimulating in the cochlear nucleus and recording the evoked neuronal activity in the central nucleus of the inferior colliculus. The arrays’ recording quality has also been quantified in vivo with neuronal spike activity recorded up to 566 days after implantation. Histopathology evaluation of neurons and astrocytes using immunohistochemical stains indicated minimal alterations of tissue architecture after chronic implantation. PMID:22020666

  15. Soft Tissue Grafting Around Teeth and Implants.

    PubMed

    Deeb, George R; Deeb, Janina Golob

    2015-08-01

    The presence of healthy attached tissue at the tooth and implant soft tissue interface correlates with long-term success and stability in function and esthetics. There are several soft tissue grafting procedures that increase the volume of keratinized tissue and provide coverage on both teeth and implants. Many of these techniques can be used in conjunction with implant placement, or after placement as a means of salvage. This article describes the techniques for augmentation of keratinized tissue as well as root and implant coverage. These tools should be in the armamentarium of oral and maxillofacial surgeons providing implant services. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Lead-related complications after DDD pacemaker implantation.

    PubMed

    Dębski, Maciej; Ulman, Mateusz; Ząbek, Andrzej; Boczar, Krzysztof; Haberka, Kazimierz; Kuniewicz, Marcin; Lelakowski, Jacek; Małecka, Barbara

    2018-04-10

    Pacing leads remain the weakest link in pacemaker systems despite advances in manufacturing technology. To assess the long-term pacing lead performance in an unselected real-life cohort following primary DDD pacing system implantation. A single-centre retrospective analysis of patients who underwent DDD pacing system implantation between October 1984 and December 2014 and were followed up until August 2016 was conducted. The inclusion criterion was at least one follow-up visit following post-implant discharge. The performance of each atrial and ventricular lead implanted was evaluated during the follow-up period, and the incidence of and predictive factors for lead dislodgement and failure were analysed. The data of 3771 patients and 24431.8 patient-years of follow-up were analysed. The mean follow-up of patients was 77.7 ± 61.8 months. During the study period, 7887 transvenous atrial and right ventricular pacing leads were implanted. Lead dislodgement occurred in 94 (1.2%) leads [92 (2.4%) patients], perforation in 11 (0.1%) leads [10 (0.3%) patients] and lead failure in 329 (4.2%) leads [275 (7.3%) patients]. Atrial lead position was a predictive factor for lead dislodgement, while age at implantation, polyurethane 80A insulation, subclavian vein access, unipolar lead construction and lead manufacturer were multivariate predictors of lead failure. Leads with polyurethane 80A insulation, unipolar construction and implantation via subclavian vein puncture exhibited the worst long-term performance.

  17. [Cochlear implant in children: rational, indications and cost/efficacy].

    PubMed

    Martini, A; Bovo, R; Trevisi, P; Forli, F; Berrettini, S

    2013-06-01

    this advantage persists in the subsequent years. With regard to cochlear implantation in children older than 12 months the studies show better hearing and linguistic results in children implanted at earlier ages. A sensitive period under 24-36 months has been identified over which cochlear implantation is reported to be less effective in terms of improvement in speech and hearing results. With regard to clinical effectiveness of bilateral cochlear implantation, greater benefits from bilateral implants compared to monolateral ones when assessing hearing in quiet and in noise and in sound localization abilities are reported to be present in both case of simultaneous or sequential bilateral implantation. However, with regard to the delay between the surgeries in sequential bilateral implantation, although benefit is reported to be present even after very long delays, on average long delays between surgeries seems to negatively affect the outcome with the second implant. With regard to benefits after cochlear implantation in children with multiple disabilities, benefits in terms of speech perception and communication as well as in quality of the daily life are reported even if benefits are slower and lower in comparison to those generally attained by implanted children without additional disabilities. Regarding the costs/efficacy ratio, the CI is expensive, in particular because of the cost of the high technological device, long life support, but even if healthcare costs are high, the savings in terms of indirect costs and quality of life are important. The CI, in fact, has a positive impact in terms of quality of life.

  18. A novel neural prosthesis providing long-term electrocorticography recording and cortical stimulation for epilepsy and brain-computer interface.

    PubMed

    Romanelli, Pantaleo; Piangerelli, Marco; Ratel, David; Gaude, Christophe; Costecalde, Thomas; Puttilli, Cosimo; Picciafuoco, Mauro; Benabid, Alim; Torres, Napoleon

    2018-05-11

    OBJECTIVE Wireless technology is a novel tool for the transmission of cortical signals. Wireless electrocorticography (ECoG) aims to improve the safety and diagnostic gain of procedures requiring invasive localization of seizure foci and also to provide long-term recording of brain activity for brain-computer interfaces (BCIs). However, no wireless devices aimed at these clinical applications are currently available. The authors present the application of a fully implantable and externally rechargeable neural prosthesis providing wireless ECoG recording and direct cortical stimulation (DCS). Prolonged wireless ECoG monitoring was tested in nonhuman primates by using a custom-made device (the ECoG implantable wireless 16-electrode [ECOGIW-16E] device) containing a 16-contact subdural grid. This is a preliminary step toward large-scale, long-term wireless ECoG recording in humans. METHODS The authors implanted the ECOGIW-16E device over the left sensorimotor cortex of a nonhuman primate ( Macaca fascicularis), recording ECoG signals over a time span of 6 months. Daily electrode impedances were measured, aiming to maintain the impedance values below a threshold of 100 KΩ. Brain mapping was obtained through wireless cortical stimulation at fixed intervals (1, 3, and 6 months). After 6 months, the device was removed. The authors analyzed cortical tissues by using conventional histological and immunohistological investigation to assess whether there was evidence of damage after the long-term implantation of the grid. RESULTS The implant was well tolerated; no neurological or behavioral consequences were reported in the monkey, which resumed his normal activities within a few hours of the procedure. The signal quality of wireless ECoG remained excellent over the 6-month observation period. Impedance values remained well below the threshold value; the average impedance per contact remains approximately 40 KΩ. Wireless cortical stimulation induced movements of the upper

  19. Long-term follow-up of implantable cardioverter-defibrillators in adult congenital heart disease patients: indications and outcomes.

    PubMed

    Santharam, Sandhya; Hudsmith, Lucy; Thorne, Sara; Clift, Paul; Marshall, Howard; De Bono, Joseph

    2017-03-01

    Ventricular arrhythmias are a major cause of mortality in adult congenital heart disease (ACHD) patients. The European Society of Cardiology guidelines state that implantable cardioverter-defibrillators (ICD) should be considered in patients with congenital heart disease following spontaneous sustained ventricular tachycardia (VT) or cardiac arrest and in patients at presumed high risk. This study sought to analyse the circumstances in which ACHD patients received ICD and to assess outcomes of ICD implantation, including therapies delivered and the rate of complications. A retrospective review was performed of all adult patients with congenital heart disease undergoing ICD implant between 2000 and 2014, in a large quaternary referral centre with over 4000 adults with congenital heart disease under active follow-up. Demographics: 42 patients with congenital heart disease had ICD implants: 55% male; age range 21-71 years and mean age 45 years. Mean age at implantation of ICD was 41 years. Mean follow-up was 5 years. Diagnosis: 50% of patients had repaired tetralogy of Fallot (TOF). Twelve per cent of patients had repaired transposition of the great arteries. Reason for ICD: 15 patients (35.7%) received ICD after sustained VT. Eleven patients (26.2%) received ICD after cardiac arrest. Sixteen (38%) had ICD implanted as primary prophylaxis. Outcome: Since implantation, six patients received an appropriate full-output shock for VT from ICD. Nineteen (45%) patients suffered significant complications (inappropriate shocks 11, inappropriate anti-tachycardia pacing resulting in VF 1, infection requiring extraction 3, lead abnormalities 3, and pneumothorax 1). Equal proportions of primary and secondary prevention patients received appropriate shocks. Most patients had ICD for secondary prevention (62%), and the majority had repaired TOF. There was a 2.9% annual appropriate shock rate. However, there was a high incidence of complications with more than a third suffering a

  20. 21 CFR 509.6 - Added poisonous or deleterious substances.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Added poisonous or deleterious substances. 509.6...-PACKAGING MATERIAL General Provisions § 509.6 Added poisonous or deleterious substances. (a) Use of an added... approved under the criteria of section 409 of the act, or when the added poisonous or deleterious substance...

  1. 21 CFR 509.6 - Added poisonous or deleterious substances.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 6 2014-04-01 2014-04-01 false Added poisonous or deleterious substances. 509.6...-PACKAGING MATERIAL General Provisions § 509.6 Added poisonous or deleterious substances. (a) Use of an added... approved under the criteria of section 409 of the act, or when the added poisonous or deleterious substance...

  2. 21 CFR 509.6 - Added poisonous or deleterious substances.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 6 2013-04-01 2013-04-01 false Added poisonous or deleterious substances. 509.6...-PACKAGING MATERIAL General Provisions § 509.6 Added poisonous or deleterious substances. (a) Use of an added... approved under the criteria of section 409 of the act, or when the added poisonous or deleterious substance...

  3. 21 CFR 509.6 - Added poisonous or deleterious substances.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Added poisonous or deleterious substances. 509.6...-PACKAGING MATERIAL General Provisions § 509.6 Added poisonous or deleterious substances. (a) Use of an added... approved under the criteria of section 409 of the act, or when the added poisonous or deleterious substance...

  4. 21 CFR 109.6 - Added poisonous or deleterious substances.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 2 2011-04-01 2011-04-01 false Added poisonous or deleterious substances. 109.6...-PACKAGING MATERIAL General Provisions § 109.6 Added poisonous or deleterious substances. (a) Use of an added... approved under the criteria of section 409 of the act, or when the added poisonous or deleterious substance...

  5. 21 CFR 109.6 - Added poisonous or deleterious substances.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false Added poisonous or deleterious substances. 109.6...-PACKAGING MATERIAL General Provisions § 109.6 Added poisonous or deleterious substances. (a) Use of an added... approved under the criteria of section 409 of the act, or when the added poisonous or deleterious substance...

  6. 21 CFR 509.6 - Added poisonous or deleterious substances.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 6 2012-04-01 2012-04-01 false Added poisonous or deleterious substances. 509.6...-PACKAGING MATERIAL General Provisions § 509.6 Added poisonous or deleterious substances. (a) Use of an added... approved under the criteria of section 409 of the act, or when the added poisonous or deleterious substance...

  7. 21 CFR 109.6 - Added poisonous or deleterious substances.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 2 2014-04-01 2014-04-01 false Added poisonous or deleterious substances. 109.6...-PACKAGING MATERIAL General Provisions § 109.6 Added poisonous or deleterious substances. (a) Use of an added... approved under the criteria of section 409 of the act, or when the added poisonous or deleterious substance...

  8. [Use of porous titanium nickelide dental implants].

    PubMed

    Radkevich, A A; Galonskiĭ, V G; Gantimurov, A A

    2013-01-01

    The paper presents the results of 20 years clinical experience in dental prosthetics with the use of porous titanium nickelide dental implants. Implants were placed in 565 patients aged 15-17 years. Long-term results analysis showed restorations to function properly after mean follow-up period of 8 years in 435 patients (78.2%) proving this material to be clinically successful.

  9. Exploring consequences of short- and long-term deafness on speech production: a lip-tube perturbation study.

    PubMed

    Turgeon, Christine; Prémont, Amélie; Trudeau-Fisette, Paméla; Ménard, Lucie

    2015-05-01

    Studies have reported strong links between speech production and perception. We aimed to evaluate the role of long- and short-term auditory feedback alteration on speech production. Eleven adults with normal hearing (controls) and 17 cochlear implant (CI) users (7 pre-lingually deaf and 10 post-lingually deaf adults) were recruited. Short-term auditory feedback deprivation was induced by turning off the CI or by providing masking noise. Acoustic and articulatory measures were obtained during the production of /u/, with and without a tube inserted between the lips (perturbation), and with and without auditory feedback. F1 values were significantly different between the implant OFF and ON conditions for the pre-lingually deaf participants. In the absence of auditory feedback, the pre-lingually deaf participants moved the tongue more forward. Thus, a lack of normal auditory experience of speech may affect the internal representation of a vowel.

  10. Long-term physical and psychological effects of the Vajont disaster.

    PubMed

    Zaetta, Cristina; Santonastaso, Paolo; Favaro, Angela

    2011-01-01

    Few studies to date investigated the long-term consequences of disasters on physical health. The aim of the present report was to study the consequence on physical health of exposure to the Vajont disaster after 40 years. We also explored the effects of severity of trauma, posttraumatic stress disorder (PTSD), and major depression disorder on physical health and health-related quality of life. Sixty survivors of the Vajont disaster and 48 control subjects of similar gender, education, and age participated in the study. Physician-reported and subjective measures of physical health have been employed. Survivors reported a greater number of physical complaints than controls (p<0.001), and some type of diseases showed a significant relationship with PTSD or PTSD symptoms. Quality of life differed between the two groups as regards the perception of physical health. The number of intrusive PTSD symptoms showed a significant negative effect on the quality of life of survivors. Our study shows that large-scale disasters such as the Vajont one may have deleterious effects on both psychological and physical health.

  11. Long-term physical and psychological effects of the Vajont disaster

    PubMed Central

    Zaetta, Cristina; Santonastaso, Paolo; Favaro, Angela

    2011-01-01

    Background Few studies to date investigated the long-term consequences of disasters on physical health. Objective The aim of the present report was to study the consequence on physical health of exposure to the Vajont disaster after 40 years. We also explored the effects of severity of trauma, posttraumatic stress disorder (PTSD), and major depression disorder on physical health and health-related quality of life. Method Sixty survivors of the Vajont disaster and 48 control subjects of similar gender, education, and age participated in the study. Physician-reported and subjective measures of physical health have been employed. Results Survivors reported a greater number of physical complaints than controls (p<0.001), and some type of diseases showed a significant relationship with PTSD or PTSD symptoms. Quality of life differed between the two groups as regards the perception of physical health. The number of intrusive PTSD symptoms showed a significant negative effect on the quality of life of survivors. Conclusions Our study shows that large-scale disasters such as the Vajont one may have deleterious effects on both psychological and physical health. PMID:22893826

  12. Speech production in experienced cochlear implant users undergoing short-term auditory deprivation

    NASA Astrophysics Data System (ADS)

    Greenman, Geoffrey; Tjaden, Kris; Kozak, Alexa T.

    2005-09-01

    This study examined the effect of short-term auditory deprivation on the speech production of five postlingually deafened women, all of whom were experienced cochlear implant users. Each cochlear implant user, as well as age and gender matched control speakers, produced CVC target words embedded in a reading passage. Speech samples for the deafened adults were collected on two separate occasions. First, the speakers were recorded after wearing their speech processor consistently for at least two to three hours prior to recording (implant ``ON''). The second recording occurred when the speakers had their speech processors turned off for approximately ten to twelve hours prior to recording (implant ``OFF''). Acoustic measures, including fundamental frequency (F0), the first (F1) and second (F2) formants of the vowels, vowel space area, vowel duration, spectral moments of the consonants, as well as utterance duration and sound pressure level (SPL) across the entire utterance were analyzed in both speaking conditions. For each implant speaker, acoustic measures will be compared across implant ``ON'' and implant ``OFF'' speaking conditions, and will also be compared to data obtained from normal hearing speakers.

  13. Executive Functioning and Speech-Language Skills Following Long-Term Use of Cochlear Implants

    ERIC Educational Resources Information Center

    Kronenberger, William G.; Colson, Bethany G.; Henning, Shirley C.; Pisoni, David B.

    2014-01-01

    Neurocognitive processes such as executive functioning (EF) may influence the development of speech-language skills in deaf children after cochlear implantation in ways that differ from normal-hearing, typically developing children. Conversely, spoken language abilities and experiences may also exert reciprocal effects on the development of EF.…

  14. Pathologic and physiologic effects associated with long-term intracoelomic transmitters in captive Siberian sturgeon

    USGS Publications Warehouse

    Boone, S. Shaun; Divers, Stephen J.; Camus, Alvin C.; Peterson, Douglas C.; Jennings, Cecil A.; Shelton, James L.; Hernandez, Sonia M.

    2015-01-01

    Intracoelomic transmitters are commonly used to evaluate migratory patterns, distribution, and habitat use of many species of fish. Currently, transmitter implantation relies mostly on the assumption that transmitters do not cause any adverse physiological or pathological effects on the animal. To investigate these effects, we surgically implanted 60 Siberian Sturgeon Acipenser baeri with transmitters that weighed less than 2% of their body weight. Postoperative assessments were conducted at 1, 2, 8, 12, 26, and 55 weeks to evaluate surgical healing and transmitter retention. Blood samples were collected before and after the 55-week study for serum cortisol analysis. Overall transmitter loss was 32%. Minor to moderate adhesions were noted at necropsy but did not appear to affect organ function. One fish was noted to have an intraintestinal transmitter at necropsy, but the fish was in overall good health. Long-term transmitter presence does not appear to increase serum cortisol levels or affect overall growth more than nontransmitter fish. Although long-term telemetry studies can be undertaken with minimal concern for negative physiological or pathological effects from transmitters, researchers should be aware that transmitter loss rates may be higher than previously thought. Mechanisms for transmitter loss may include expulsion through the surgical incision, expulsion through the mucocutaneous junction between the large intestine and the vent, or intraintestinal capture and expulsion through the vent. Received February 10, 2013; accepted June 10, 2013

  15. Long-term durability of sacral nerve stimulation therapy for chronic fecal incontinence.

    PubMed

    Hull, Tracy; Giese, Chad; Wexner, Steven D; Mellgren, Anders; Devroede, Ghislain; Madoff, Robert D; Stromberg, Katherine; Coller, John A

    2013-02-01

    Limited data have been published regarding the long-term results of sacral nerve stimulation, or sacral neuromodulation, for severe fecal incontinence. The aim was to assess the outcome of sacral nerve stimulation with the use of precise tools and data collection, focusing on the long-term durability of the therapy. Five-year data were analyzed. Patients entered in a multicenter, prospective study for fecal incontinence were followed at 3, 6, and 12 months and annually after device implantation. Patients with chronic fecal incontinence in whom conservative treatments had failed or who were not candidates for more conservative treatments were selected. Patients with ≥ 50% improvement over baseline in fecal incontinence episodes per week during a 14-day test stimulation period received sacral nerve stimulation therapy. Patients were assessed with a 14-day bowel diary and Fecal Incontinence Quality of Life and Fecal Incontinence Severity Index questionnaires. Therapeutic success was defined as ≥ 50% improvement over baseline in fecal incontinence episodes per week. All adverse events were collected. A total of 120 patients (110 women; mean age, 60.5 years) underwent implantation. Seventy-six of these patients (63%) were followed a minimum of 5 years (maximum, longer than 8 years) and are the basis for this report. Fecal incontinence episodes per week decreased from a mean of 9.1 at baseline to 1.7 at 5 years, with 89% (n = 64/72) having ≥ 50% improvement (p < 0.0001) and 36% (n = 26/72) having complete continence. Fecal Incontinence Quality of Life scores also significantly improved for all 4 scales between baseline and 5 years (n = 70; p < 0.0001). Twenty-seven of the 76 (35.5%) patients required a device revision, replacement, or explant. The therapeutic effect and improved quality of life for fecal incontinence is maintained 5 years after sacral nerve stimulation implantation and beyond. Device revision, replacement, or explant rate was acceptable, but future

  16. Short, Medium and Long Term Complications After Total Anatomical Shoulder Arthroplasty

    PubMed Central

    Gregory, T.M.; Boukebous, B.; Gregory, J.; Pierrart, J.; Masemjean, E.

    2017-01-01

    Total shoulder arthroplasty (TSA) is an effective approach for the treatment of a variety of clinical conditions affecting the shoulder, including osteoarthritis, inflammatory arthritis and osteonecrosis, and the number of TSA implanted has grown exponentially over the past decade. This review gives an update of the major complications, mainly infections, instability and loosening, encountered after TSA, based on a corpus of recent publications and a dynamic approach: The review focuses on the causes of glenoid loosening, which account for 80% of the complication, and underlines the importance of glenoid positioning in the recovery of early shouder function and in the long term survival rate of TSA. PMID:29152008

  17. Retention of gene expression in porcine islets after agarose encapsulation and long-term culture

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dumpala, Pradeep R., E-mail: pdumpala@rixd.org; Holdcraft, Robert W.; Martis, Prithy C.

    Agarose encapsulation of porcine islets allows extended in vitro culture, providing ample time to determine the functional capacity of the islets and conduct comprehensive microbiological safety testing prior to implantation as a treatment for type 1 diabetes mellitus. However, the effect that agarose encapsulation and long-term culture may have on porcine islet gene expression is unknown. The aim of the present study was to compare the transcriptome of encapsulated porcine islets following long-term in vitro culture against free islets cultured overnight. Global gene expression analysis revealed no significant change in the expression of 98.47% of genes. This indicates that the gene expressionmore » profile of free islets is highly conserved following encapsulation and long-term culture. Importantly, the expression levels of genes that code for critical hormones secreted by islets (insulin, glucagon, and somatostatin) as well as transcripts encoding proteins involved in their packaging and secretion are unchanged. While a small number of genes known to play roles in the insulin secretion and insulin signaling pathways are differentially expressed, our results show that overall gene expression is retained following islet isolation, agarose encapsulation, and long-term culture. - Highlights: • Effect of agarose encapsulation and 8 week culture on porcine islets was analyzed. • Transcriptome analysis revealed no significant change in a majority (98%) of genes. • Agarose encapsulation allows for long-term culture of porcine islets. • Islet culture allows for functional and microbial testing prior to clinical use.« less

  18. Surface modification of implants in long bone.

    PubMed

    Förster, Yvonne; Rentsch, Claudia; Schneiders, Wolfgang; Bernhardt, Ricardo; Simon, Jan C; Worch, Hartmut; Rammelt, Stefan

    2012-01-01

    Coatings of orthopedic implants are investigated to improve the osteoinductive and osteoconductive properties of the implant surfaces and thus to enhance periimplant bone formation. By applying coatings that mimic the extracellular matrix a favorable environment for osteoblasts, osteoclasts and their progenitor cells is provided to promote early and strong fixation of implants. It is known that the early bone ongrowth increases primary implant fixation and reduces the risk of implant failure. This review presents an overview of coating titanium and hydroxyapatite implants with components of the extracellular matrix like collagen type I, chondroitin sulfate and RGD peptide in different small and large animal models. The influence of these components on cells, the inflammation process, new bone formation and bone/implant contact is summarized.

  19. Surface modification of implants in long bone

    PubMed Central

    Förster, Yvonne; Rentsch, Claudia; Schneiders, Wolfgang; Bernhardt, Ricardo; Simon, Jan C.; Worch, Hartmut; Rammelt, Stefan

    2012-01-01

    Coatings of orthopedic implants are investigated to improve the osteoinductive and osteoconductive properties of the implant surfaces and thus to enhance periimplant bone formation. By applying coatings that mimic the extracellular matrix a favorable environment for osteoblasts, osteoclasts and their progenitor cells is provided to promote early and strong fixation of implants. It is known that the early bone ongrowth increases primary implant fixation and reduces the risk of implant failure. This review presents an overview of coating titanium and hydroxyapatite implants with components of the extracellular matrix like collagen type I, chondroitin sulfate and RGD peptide in different small and large animal models. The influence of these components on cells, the inflammation process, new bone formation and bone/implant contact is summarized. PMID:23507866

  20. Trapezius placement of implanted ports: understanding the procedure.

    PubMed

    Hill, Steve

    Totally implantable vascular access devices (TIVADs) are indicated for intermittent long-term intravenous access. It is widely accepted within medical literature that TIVADs are associated with statistically significant lower infection rates than other central venous access devices. Typical sites for implantation are on the anterior chest wall, using the internal jugular, axillary, cephalic or a subclavian vein. This article follows on from a previous discussion of the benefits of this approach, which illustrated and examined clinical outcomes of trapezius-placement versus anterior chest wall placed ports, for patients with metastatic subcutaneous disease on the anterior chest wall. The procedure provides a unique challenge for the clinician. This article focuses on the process of trapezius port implantation, providing an illustrative guide to understand the procedure. Trapezius port placement is a viable option for patients for whom routine sites are excluded and who require long-term intermittent vascular access.

  1. Incomplete dominance of deleterious alleles contributes substantially to trait variation and heterosis in maize

    USDA-ARS?s Scientific Manuscript database

    Deleterious alleles have long been proposed to play an important role in patterning phenotypic variation and are central to commonly held ideas explaining the hybrid vigor observed in the offspring by crossing two inbred parents. We test these ideas using evolutionary measures of sequence conservati...

  2. Long-term urethral catheterisation.

    PubMed

    Turner, Bruce; Dickens, Nicola

    This article discusses long-term urethral catheterisation, focusing on the relevant anatomy and physiology, indications for the procedure, catheter selection and catheter care. It is important that nurses have a good working knowledge of long-term catheterisation as the need for this intervention will increase with the rise in chronic health conditions and the ageing population.

  3. Long-term solar-terrestrial observations

    NASA Technical Reports Server (NTRS)

    1988-01-01

    The results of an 18-month study of the requirements for long-term monitoring and archiving of solar-terrestrial data is presented. The value of long-term solar-terrestrial observations is discussed together with parameters, associated measurements, and observational problem areas in each of the solar-terrestrial links (the sun, the interplanetary medium, the magnetosphere, and the thermosphere-ionosphere). Some recommendations are offered for coordinated planning for long-term solar-terrestrial observations.

  4. Pre-clinical evaluation of OxyChip for long-term EPR oximetry.

    PubMed

    Hou, Huagang; Khan, Nadeem; Gohain, Sangeeta; Kuppusamy, M Lakshmi; Kuppusamy, Periannan

    2018-03-16

    Tissue oxygenation is a critical parameter in various pathophysiological situations including cardiovascular disease and cancer. Hypoxia can significantly influence the prognosis of solid malignancies and the efficacy of their treatment by radiation or chemotherapy. Electron paramagnetic resonance (EPR) oximetry is a reliable method for repeatedly assessing and monitoring oxygen levels in tissues. Lithium octa-n-butoxynaphthalocyanine (LiNc-BuO) has been developed as a probe for biological EPR oximetry, especially for clinical use. However, clinical applicability of LiNc-BuO crystals is hampered by potential limitations associated with biocompatibility, biodegradation, or migration of individual bare crystals in tissue. To overcome these limitations, we have embedded LiNc-BuO crystals in polydimethylsiloxane (PDMS), an oxygen-permeable biocompatible polymer and developed an implantable/retrievable form of chip, called OxyChip. The chip was optimized for maximum spin density (40% w/w of LiNc-BuO in PDMS) and fabricated in a form suitable for implantation using an 18-G syringe needle. In vitro evaluation of the OxyChip showed that it is robust and highly oxygen sensitive. The dependence of its EPR linewidth to oxygen was linear and highly reproducible. In vivo efficacy of the OxyChip was evaluated by implanting it in rat femoris muscle and following its response to tissue oxygenation for up to 12 months. The results revealed preservation of the integrity (size and shape) and calibration (oxygen sensitivity) of the OxyChip throughout the implantation period. Further, no inflammatory or adverse reaction around the implantation area was observed thereby establishing its biocompatibility and safety. Overall, the results demonstrated that the newly-fabricated high-sensitive OxyChip is capable of providing long-term measurements of oxygen concentration in a reliable and repeated manner under clinical conditions.

  5. Long-term care: long-term care insurance--2005. End of Year Issue Brief.

    PubMed

    Tanner, Rachel; Bercaw, Lawren

    2005-12-31

    As the "Baby Boom" generation approaches retirement, state and federal lawmakers are struggling to ensure that the nation's long-term care system will provide adequate services for the growing number of senior citizens. A 2003 Administration on Aging report predicted that the elderly population will double by 2030. Accordingly, policymakers must prepare for the impending squeeze on public health and Medicaid resources. Many consumers are exploring private long-term care insurance options as a means of preparing for the cost of eldercare. Yet, a lack of market uniformity has rendered the long-term care insurance industry somewhat difficult for consumers to decipher. In addition, senior care insurance is often costly, particularly for those over age 50.

  6. Stenting of aortic coarctation: acute, intermediate, and long-term results of a prospective multi-institutional registry--Congenital Cardiovascular Interventional Study Consortium (CCISC).

    PubMed

    Holzer, Ralf; Qureshi, Shakeel; Ghasemi, Abdolrahim; Vincent, Julie; Sievert, Horst; Gruenstein, Daniel; Weber, Howard; Alday, Luis; Peirone, Alejandro; Zellers, Thomas; Cheatham, John; Slack, Michael; Rome, Jonathan

    2010-10-01

    Since the 1980s, stent implantation has evolved as an important therapeutic strategy for coarctation of the aorta. However, available data is frequently flawed by short follow-up, lack of adequate follow-up imaging, and retrospective nature of data collection. Data was prospectively collected using a multicenter registry congenital cardiovascular interventional study consortium (CCISC). Between 2000 and 2009, 302 patients from 34 centers with a median weight of 58 kg underwent stent implantation for coarctation. Eligible patients (44%) completed intermediate follow-up (3-18 months) with integrated imaging (cath, CT, MRI), whereas 21% completed long-term follow-up (>18-60 months). Procedural success was defined as UL/LL systolic gradient of less than 20 mm Hg, lack of significant recurrent obstruction, and freedom from unplanned repeat intervention. Acute procedural success was 96%. Cumulative intermediate success was 86%, and cumulative long-term success was 77%. Unplanned repeat interventions were required in 4%, and aortic wall complications were seen in 1% of patients (dissection n = 1 and aneurysm n = 3). Other adverse events (n = 15) occurred mainly acutely and included technical complications such as stent malposition (n = 9). At long-term follow-up, 23% of patients continued to have systolic blood pressure above the 95th centile, 9% had an upper-to-lower limb blood pressure gradient in excess of 20 mm Hg, and 32% were taking antihypertensive medication. This study documented acute, intermediate, and long-term outcome data comparable or superior with other surgical or interventional series. However, even with successful initial stent therapy, patients continue to require long-term follow-up and have associated long-term morbidity, relating to aortic wall complications, systemic hypertension, recurrent obstruction as well as need for repeat intervention. © 2010 Wiley-Liss, Inc.

  7. [New concepts for pressure-controlled glaucoma implants].

    PubMed

    Allemann, R; Stachs, O; Falke, K; Schmidt, W; Siewert, S; Sternberg, K; Chichkov, B; Wree, A; Schmitz, K-P; Guthoff, R F

    2013-08-01

    In industrialized countries glaucoma is one of the most common causes that leads to blindness. It is also the most common cause of irreversible blindness worldwide. In addition to local treatment of intraocular pressure and filtering glaucoma surgery, alloplastic implants are increasingly being used in glaucoma therapy. As long-term results published in the literature of commonly used implants are unsatisfactory, it seems useful to search for new concepts. In order to avoid the well-known short-term and long-term postoperative complications a pressure-controlled microstent with antiproliferative surface modifications was developed. Additionally, the functionality of such a microstent should be investigated using an animal glaucoma model. This paper describes the concept of a microstent which drains aquous humour from the anterior chamber into the suprachoroidal space. In addition, the glaucoma models described in the literature are discussed. Unfortunately, none of the methods could be reproduced permanently. First results show a correct implantation of a coated microstent with valve where the anti-proliferative effect could be demonstrated histologically. The promising results should lead to further investigations and the final goal will be the testing of the stent in the human eye.

  8. A Model of Substitution Trajectories in Sequence Space and Long-Term Protein Evolution

    PubMed Central

    Usmanova, Dinara R.; Ferretti, Luca; Povolotskaya, Inna S.; Vlasov, Peter K.; Kondrashov, Fyodor A.

    2015-01-01

    The nature of factors governing the tempo and mode of protein evolution is a fundamental issue in evolutionary biology. Specifically, whether or not interactions between different sites, or epistasis, are important in directing the course of evolution became one of the central questions. Several recent reports have scrutinized patterns of long-term protein evolution claiming them to be compatible only with an epistatic fitness landscape. However, these claims have not yet been substantiated with a formal model of protein evolution. Here, we formulate a simple covarion-like model of protein evolution focusing on the rate at which the fitness impact of amino acids at a site changes with time. We then apply the model to the data on convergent and divergent protein evolution to test whether or not the incorporation of epistatic interactions is necessary to explain the data. We find that convergent evolution cannot be explained without the incorporation of epistasis and the rate at which an amino acid state switches from being acceptable at a site to being deleterious is faster than the rate of amino acid substitution. Specifically, for proteins that have persisted in modern prokaryotic organisms since the last universal common ancestor for one amino acid substitution approximately ten amino acid states switch from being accessible to being deleterious, or vice versa. Thus, molecular evolution can only be perceived in the context of rapid turnover of which amino acids are available for evolution. PMID:25415964

  9. Factors contributing to speech perception scores in long-term pediatric cochlear implant users.

    PubMed

    Davidson, Lisa S; Geers, Ann E; Blamey, Peter J; Tobey, Emily A; Brenner, Christine A

    2011-02-01

    The objectives of this report are to (1) describe the speech perception abilities of long-term pediatric cochlear implant (CI) recipients by comparing scores obtained at elementary school (CI-E, 8 to 9 yrs) with scores obtained at high school (CI-HS, 15 to 18 yrs); (2) evaluate speech perception abilities in demanding listening conditions (i.e., noise and lower intensity levels) at adolescence; and (3) examine the relation of speech perception scores to speech and language development over this longitudinal timeframe. All 112 teenagers were part of a previous nationwide study of 8- and 9-yr-olds (N = 181) who received a CI between 2 and 5 yrs of age. The test battery included (1) the Lexical Neighborhood Test (LNT; hard and easy word lists); (2) the Bamford Kowal Bench sentence test; (3) the Children's Auditory-Visual Enhancement Test; (4) the Test of Auditory Comprehension of Language at CI-E; (5) the Peabody Picture Vocabulary Test at CI-HS; and (6) the McGarr sentences (consonants correct) at CI-E and CI-HS. CI-HS speech perception was measured in both optimal and demanding listening conditions (i.e., background noise and low-intensity level). Speech perception scores were compared based on age at test, lexical difficulty of stimuli, listening environment (optimal and demanding), input mode (visual and auditory-visual), and language age. All group mean scores significantly increased with age across the two test sessions. Scores of adolescents significantly decreased in demanding listening conditions. The effect of lexical difficulty on the LNT scores, as evidenced by the difference in performance between easy versus hard lists, increased with age and decreased for adolescents in challenging listening conditions. Calculated curves for percent correct speech perception scores (LNT and Bamford Kowal Bench) and consonants correct on the McGarr sentences plotted against age-equivalent language scores on the Test of Auditory Comprehension of Language and Peabody

  10. Removable partial denture on osseointegrated implants and natural teeth.

    PubMed

    Chang, Li-Ching; Wang, Jen-Chyan; Tasi, Chi-Cheng

    2007-01-01

    Implants have been designed to provide edentulous patients with fixed prostheses or overdentures. Recently, implant-supported fixed partial prostheses and single crowns have become successful treatment alternatives to removable and fixed partial dentures. However, few researchers have examined "removable partial dentures on implants and natural teeth". In this article, we report two patients fitted with "removable partial dentures on implants and natural teeth". The patients were satisfied with their dentures in terms of function and aesthetics. Regular follow-up visits revealed that the periodontal and peri-implant conditions were stable. There was no evidence of excessive intrusion or mobility of the teeth, nor were any visible changes in the bone levels of the natural teeth or implants noted on radiographs. Since the average duration of observation was about 38 months, further follow-up examinations are necessary to determine whether these dentures remain stable long-term.

  11. Long-term characterization of neural electrodes based on parylene-caulked polydimethylsiloxane substrate.

    PubMed

    Jeong, Jinmo; Chou, Namsun; Kim, Sohee

    2016-06-01

    This study investigates the mechanical and long-term electrical properties of parylene-caulked polydimethylsiloxane (PDMS) as a substrate for implantable electrodes. The parylene-caulked PDMS is a structure where particles of parylene fill the porous surface of PDMS. This material is expected to have low water absorption and desirable mechanical properties such as flexibility and elasticity that are beneficial in many biomedical applications. To evaluate the mechanical property and electrical stability of parylene-caulked PDMS for potential in-vivo uses, tensile tests were conducted firstly, which results showed that the mechanical strength of parylene-caulked PDMS was comparable to that of native PDMS. Next, surface electrodes based on parylene-caulked PDMS were fabricated and their impedance was measured in phosphate-buffered saline (PBS) solution at 36.5 °C over seven months. The electrodes based on parylene-caulked PDMS exhibited the improved stability in impedance over time than native PDMS. Thus, with improved electrical stability in wet environment and preserved mechanical properties of PDMS, the electrodes based on parylene-caulked PDMS are expected to be suitable for long-term in-vivo applications.

  12. Immediate loading of mandibular overdentures supported by one-piece, direct metal laser sintering mini-implants: a short-term prospective clinical study.

    PubMed

    Mangano, Francesco G; Caprioglio, Alberto; Levrini, Luca; Farronato, Davide; Zecca, Piero A; Mangano, Carlo

    2015-02-01

    Only a few studies have dealt with immediately loaded, unsplinted mini-implants supporting ball attachment-retained mandibular overdentures (ODs). The aim of this study is to evaluate treatment outcomes of ball attachment-retained mandibular ODs supported by one-piece, unsplinted, immediately loaded, direct metal laser sintering (DMLS) mini-implants. Over a 4-year period (2009 to 2012), all patients referred to the Dental Clinic, University of Varese, and to a private practice for treatment with mandibular ODs were considered for inclusion in this study. Each patient received three or four DMLS mini-implants. Immediately after implant placement, a mandibular OD was connected to the implants. At each annual follow-up session, clinical and radiographic parameters were assessed, including the following outcome measures: 1) implant failures; 2) peri-implant marginal bone loss; and 3) complications. Statistical analysis was conducted using a life-table analysis. A total of 231 one-piece DMLS mini-implants were inserted in 62 patients. After 4 years of loading, six implants failed, giving an overall cumulative survival rate of 96.9%. The mean distance between the implant shoulder and the first visible bone-to-implant contact was 0.38 ± 0.25 and 0.62 ± 0.20 mm at the 1- and 4-year follow-up examinations, respectively. An incidence of 6.0% of biologic complications was reported; prosthetic complications were more frequent (12.9%). Within the limits of this study, it can be concluded that the immediate loading of one-piece, unsplinted, DMLS titanium mini-implants by means of ball attachment-supported mandibular ODs is a successful treatment procedure. Long-term follow-up studies are needed to confirm these results.

  13. R-LOCUS DELETERIOUS FACTORS IN MORMONIELLA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Whiting, P.W.

    1962-01-01

    New data are presented on 37 R-locus mutant genes containing deleterious factors or crossover suppressors. Twenty-seven of these genes are among the 206 recognizable eye-color mutants previously found by others in experiments in which wild-type males were irradiated and mated, siring 11062 daughters examined, mutation rate 1.86%. With the addition of eight mutants from later simdlar tests there were 38 mutants failing to breed, probably being dominant steriles, and seven immature, probably dominant lethals. Of the l60 mutants given successful breeding test, 80 were normal and 80 contained delcterious factors of different types - lethals, near-steriles, femalesteriles, and male-stertles. Ratemore » of deleterious factor productdon differs according to the factor mutating to produce the eye-color marker. Among the l07 genes changed in factor S alone, 68 were also deleterious (63.6%) but for the 45 in O, there were only nine (20.0%), suggesting a more sensitive region near S. More than one deleterious factor may be produced simultaneously with an eye-color change and one defeet may mask others. The gene which forms a temporary unit of segregation in heterozygotes is of a higher order of magnitude than units of heredity (gene elements, cistrons) which may be permanently present dn the germ plasm. Because of the high mutation rate to the marker eye colors scarlet and oyster white, the genetical structure of the R region may be easily studied. (auth)« less

  14. Long-term associative learning predicts verbal short-term memory performance.

    PubMed

    Jones, Gary; Macken, Bill

    2018-02-01

    Studies using tests such as digit span and nonword repetition have implicated short-term memory across a range of developmental domains. Such tests ostensibly assess specialized processes for the short-term manipulation and maintenance of information that are often argued to enable long-term learning. However, there is considerable evidence for an influence of long-term linguistic learning on performance in short-term memory tasks that brings into question the role of a specialized short-term memory system separate from long-term knowledge. Using natural language corpora, we show experimentally and computationally that performance on three widely used measures of short-term memory (digit span, nonword repetition, and sentence recall) can be predicted from simple associative learning operating on the linguistic environment to which a typical child may have been exposed. The findings support the broad view that short-term verbal memory performance reflects the application of long-term language knowledge to the experimental setting.

  15. Asthma Medicines: Long-Term Control

    MedlinePlus

    ... Size Email Print Share Asthma Medicines: Long-term Control Page Content Article Body Corticosteroids Synthetic versions of ... form, they are used exclusively for long-term control; they are not very effective for acute symptoms. ...

  16. The role of single immediate loading implant in long Class IV Kennedy mandibular partial denture.

    PubMed

    Mohamed, Gehan F; El Sawy, Amal A

    2012-10-01

    The treatment of long-span Kennedy class IV considers a prosthodontic challenge. This study evaluated the integrity of principle abutments in long Kennedy class IV clinically and radiographically, when rehabilitated with conventional metallic partial denture as a control group and mandibular partial overdentures supported with single immediately loaded implant in symphyseal as a study group. Twelve male patients were divided randomly allotted into two equal groups. First group patients received removable metallic partial denture, whereas in the second group, patients received partial overdentures supported with single immediately loaded implant in symphyseal region. The partial dentures design in both groups was the same. Long-cone paralleling technique and transmission densitometer were used at the time of denture insertion, 3, 6, and 12 months. Gingival index, bone loss, and optical density were measured for principle abutments during the follow-up. A significant reduction in bone loss and density were detected in group II comparing with group I. Gingival index had no significant change (p-value < 0.05). A single symphyseal implant in long span class IV Kennedy can play a pivotal role to improve the integrity of the principle abutments and alveolar bone support. © 2010 Wiley Periodicals, Inc.

  17. Long-Term Follow-Up of Flap Prefabrication in Facial Reconstruction.

    PubMed

    Wang, Weixin; Zhao, Muxin; Tang, Yong; Chen, Wen; Yang, Zhe; Ma, Ning; Xu, Lisi; Feng, Jun; Li, Yangqun

    2017-07-01

    Flap prefabrication is to turn a random flap into an axial flap by transferring a vascular pedicle. In the past 13 years, we have prefabricated 20 flaps in 20 patients by the superficial temporal artery and its concomitant veins. Typically, a 50- to 800-mL tissue expander was implanted in the donor site. After flap maturation, the prefabricated flap was raised and transferred locally to cover the large defect on the face. All the cases were followed up regularly. The patients' age were between 3 and 27 years, the size of the flaps were between 3.5 × 5.5 cm and 13 × 15 cm, the superficial temporal artery length was between 10 and 15 cm. All flaps were transferred successfully: 10 of the flaps had venous congestion, partial epidermis exfoliation and flap necrosis occurred in 4 flaps. All cases were followed up for at least 1 year, the longest follow-up period was 9 years. Long-term follow-up results showed the prefabricated flap survived in good condition and had a satisfactory outcome. Because flap prefabrication is practical, and long-term follow-ups have proved its preferable characters and stability, it is a fine method for large area facial reconstructions.

  18. Systematic review of the effectiveness of polyurethane-coated compared with textured silicone implants in breast surgery.

    PubMed

    Duxbury, Paula J; Harvey, James R

    2016-04-01

    Silicone gel implants are used worldwide for breast augmentation and breast reconstruction. Textured silicone implants are the most commonly placed implant, but polyurethane-coated implants are increasingly being used in an attempt to ameliorate the long-term complications associated with implant insertion. This systematic review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines. Electronic searches of MEDLINE, EMBASE, the Cochrane Library and www.ClinicalTrials.gov were undertaken in March 2014 using keywords. Following data extraction, 18 studies were included in the review, including four core studies of textured silicone implants and five studies reporting outcomes for polyurethane-coated silicone implants. There are no clear data reporting revision rates in patients treated with polyurethane implants. In the primary reconstructive setting, capsular contracture rates with silicone implants are 10-15% at 6 years, whilst studies of polyurethane implants report rates of 1.8-3.4%. In the primary augmentation setting, core studies show a capsular contracture rate of 2-15% at 6 years compared with 0.4-1% in polyurethane-coated implants; however, the polyurethane studies are limited by their design and poor follow-up. The use of polyurethane implants should be considered a safe alternative to textured silicone implants. It is likely that an implant surface does influence short- and long-term outcomes; however, the extent of any benefit cannot be determined from the available evidence base. Future implant studies should target the short- and long-term benefits of implant surfacing by procedure with defined outcome measures; a head-to-head comparison would help clarify outcomes. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  19. Macro design effects on stress distribution around implants: a photoelastic stress analysis.

    PubMed

    Ozkir, Serhat Emre; Terzioglu, Hakan

    2012-01-01

    Biomechanics is one of the main factors for achieving long-term success of implant supported prostheses. Long-term failures mostly depend on biomechanical complications. It is important to distinguish the effects of macro design of the implants. In this study, the photoelastic response of four different types of implants that were inserted with different angulations were comparatively analyzed. The implant types investigated were screw cylinder (ITI, Straumann AG, Basel, Switzerland), stepped cylinder (Frialit2, Friadent GmbH, Manheim, Germany), root form (Camlog Rootline, Alatatec, Wilshelm, Germany), and cylindrical implant, with micro-threads on the implant neck (Astra, AstraTech, Mölndal, Sweden). In the test models, one of the implants was inserted straight, while the other one was aligned mesially with 15° angles. The superstructures were prepared as single crowns. A 150N loading was applied to the restorations throughout the test. A comparison of the implant designs showed that there were no significant differences between the straight implants; however, between the inclined implants, the most favorable stress distribution was seen with the stepped cylinder implants. The least favorable stress concentration was observed around the root formed implants. Microthreads around the implant neck appeared to be effective in a homogenous stress distribution. Observations showed that misaligned implants caused less stress than straight implants, but the stress concentrations were not homogenous. As there were observable differences between the implant types, straight placed cylindrical implants showed better stress distribution characteristics, while inclined tapering implants had better stress distribution characteristics.

  20. Long-Term Clinical Outcome of Arrhythmogenic Right Ventricular Cardiomyopathy in Individuals With a p.S358L Mutation in TMEM43 Following Implantable Cardioverter Defibrillator Therapy.

    PubMed

    Hodgkinson, Kathleen A; Howes, A J; Boland, Paul; Shen, Xiou Seegar; Stuckless, Susan; Young, Terry-Lynn; Curtis, Fiona; Collier, Ashley; Parfrey, Patrick S; Connors, Sean P

    2016-03-01

    We previously showed a survival benefit of the implantable cardioverter defibrillator (ICD) in males with arrhythmogenic right ventricular cardiomyopathy caused by a p.S358L mutation in TMEM43. We present long-term data (median follow-up 8.5 years) after ICD for primary (PP) and secondary prophylaxis in males and females, determine whether ICD discharges for ventricular tachycardia/ventricular fibrillation were equivalent to an aborted death, and assess relevant clinical predictors. We studied 24 multiplex families segregating an autosomal dominant p.S358L mutation in TMEM43. We compared survival in 148 mutation carriers with an ICD to 148 controls matched for age, sex, disease status, and family. Of 80 male mutation carriers with ICDs (median age at implantation 31 years), 61 (76%) were for PP; of 68 females (median age at implantation 43 years), 66 (97%) were for PP. In males, irrespective of indication, survival was better in the ICD groups compared with control groups (relative risk 9.3 [95% confidence interval 3.3-26] for PP and 9.7 [95% confidence interval 3.2-29.6] for secondary prophylaxis). For PP females, the relative risk was 3.6 (95% confidence interval 1.3-9.5). ICD discharge-free survival for ventricular tachycardia/ventricular fibrillation ≥ 240 beats per minute was equivalent to the control survival rate. Ectopy (≥ 1000 premature ventricular complexes/24 hours) was the only independent clinical predictor of ICD discharge in males, and no predictor was identified in females. ICD therapy is indicated for PP in postpubertal males and in females ≥ 30 years with the p.S358L TMEM43 mutation. ICD termination of rapid ventricular tachycardia/ventricular fibrillation can reasonably be considered an aborted death. © 2016 American Heart Association, Inc.

  1. Implants in bone: part II. Research on implant osseointegration: material testing, mechanical testing, imaging and histoanalytical methods.

    PubMed

    von Wilmowsky, Cornelius; Moest, Tobias; Nkenke, Emeka; Stelzle, Florian; Schlegel, Karl Andreas

    2014-12-01

    In order to determine whether a newly developed implant material conforms to the requirements of biocompatibility, it must undergo rigorous testing. To correctly interpret the results of studies on implant material osseointegration, it is necessary to have a sound understanding of all the testing methods. The aim of this overview is to elucidate the methods that are used for the experimental evaluation of the osseointegration of implant materials. In recent decades, there has been a constant proliferation of new materials and surface modifications in the field of dental implants. This continuous development of innovative biomaterials requires a precise and detailed evaluation in terms of biocompatibility and implant healing before clinical use. The current gold standard is in vivo animal testing on well validated animal models. However, long-term outcome studies on patients have to follow to finally validate and show patient benefit. No experimental set-up can provide answers for all possible research questions. However, a certain transferability of the results to humans might be possible if the experimental set-up is carefully chosen for the aspects and questions being investigated. To enhance the implant survival rate in the rising number of patients with chronic diseases which compromise wound healing and osseointegration, dental implant research on compromised animal models will further gain importance in future.

  2. Short- to long-term results of Ahmed glaucoma valve in the management of elevated intraocular pressure in patients with pediatric uveitis.

    PubMed

    Eksioglu, Umit; Yakin, Mehmet; Sungur, Gulten; Satana, Banu; Demirok, Gulizar; Balta, Ozgur; Ornek, Firdevs

    2017-06-01

    The aim of this study was to evaluate the long-term outcome of Ahmed glaucoma valve (AGV) implant for elevated intraocular pressure (IOP) in pediatric patients with uveitis. This was a retrospective chart review. The study included 16 eyes (11 children) with uveitis. Success was defined as having IOP between 6 and 21 mm Hg with (qualified success) or without (complete success) antiglaucoma medications and without the need for further glaucoma or tube extraction surgery. Mean age of patients at the time of AGV implantation was 14.19 ± 3.25 years. AGV implantation was the first glaucoma surgical procedure in 12 eyes (75%). Average postoperative follow-up period was 64.46 ± 33.56 months. Mean preoperative IOP was 33.50 ± 7.30 mm Hg versus 12.69 ± 3.20 mm Hg at the last follow-up visit (p < 0.001). Three eyes (18.7%) were determined as cases of "failure" because of tube removal in 2 eyes and a second AGV implantation in 1 eye. The cumulative probability of complete success was 68.8% at 6 months, 56.3% at 12 months, 49.2% at 36 months, 42.2% at 48 months, and 35.2% at 84 months, and the cumulative probability of eyes without complication was 75.0% at 6 months, 66.7% at 24 months, 58.3% at 36 months, 48.6% at 48 months and 24.3% at 108 months based on Kaplan-Meier survival analysis. Although AGV implant is an effective choice in the management of elevated IOP in pediatric uveitis, antiglaucoma medications are frequently needed for control of IOP. Tube exposure is an important complication in the long term. Differential diagnosis between relapse of uveitis and endophthalmitis is important in patients who received AGV implantation. Copyright © 2017 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  3. Subcutaneous implants for long-acting drug therapy in laboratory animals may generate unintended drug reservoirs.

    PubMed

    Guarnieri, Michael; Tyler, Betty M; Detolla, Louis; Zhao, Ming; Kobrin, Barry

    2014-01-01

    Long-acting therapy in laboratory animals offers advantages over the current practice of 2-3 daily drug injections. Yet little is known about the disintegration of biodegradable drug implants in rodents. Compare bioavailability of buprenorphine with the biodegradation of lipid-encapsulated subcutaneous drug pellets. Pharmacokinetic and histopathology studies were conducted in BALB/c female mice implanted with cholesterol-buprenorphine drug pellets. Drug levels are below the level of detection (0.5 ng/mL plasma) within 4-5 days of implant. However, necroscopy revealed that interstitial tissues begin to seal implants within a week. Visual inspection of the implant site revealed no evidence of inflammation or edema associated with the cholesterol-drug residue. Chemical analyses demonstrated that the residues contained 10-13% of the initial opiate dose for at least two weeks post implant. The results demonstrate that biodegradable scaffolds can become sequestered in the subcutaneous space. Drug implants can retain significant and unintended reservoirs of drugs.

  4. Subcutaneous implants for long-acting drug therapy in laboratory animals may generate unintended drug reservoirs

    PubMed Central

    Guarnieri, Michael; Tyler, Betty M.; DeTolla, Louis; Zhao, Ming; Kobrin, Barry

    2014-01-01

    Background: Long-acting therapy in laboratory animals offers advantages over the current practice of 2-3 daily drug injections. Yet little is known about the disintegration of biodegradable drug implants in rodents. Objective: Compare bioavailability of buprenorphine with the biodegradation of lipid-encapsulated subcutaneous drug pellets. Methods: Pharmacokinetic and histopathology studies were conducted in BALB/c female mice implanted with cholesterol-buprenorphine drug pellets. Results: Drug levels are below the level of detection (0.5 ng/mL plasma) within 4-5 days of implant. However, necroscopy revealed that interstitial tissues begin to seal implants within a week. Visual inspection of the implant site revealed no evidence of inflammation or edema associated with the cholesterol-drug residue. Chemical analyses demonstrated that the residues contained 10-13% of the initial opiate dose for at least two weeks post implant. Discussion: The results demonstrate that biodegradable scaffolds can become sequestered in the subcutaneous space. Conclusion: Drug implants can retain significant and unintended reservoirs of drugs. PMID:24459402

  5. Use of the Impella Device for Acute Coronary Syndrome Complicated by Cardiogenic Shock - Experience From a Single Heart Center With Analysis of Long-term Mortality.

    PubMed

    Schroeter, Marco Robin; Köhler, Herdis; Wachter, Astrid; Bleckmann, Annalen; Hasenfuß, Gerd; Schillinger, Wolfgang

    2016-12-01

    Impella is a microaxial rotary pump that is placed across the aortic valve to expel aspirated blood from the left ventricle into the ascending aorta; it can be used in cardiogenic shock. While previous studies have evaluated the efficacy and safety of the Impella device, more clinically relevant data are necessary, especially with regard to outcomes. We screened our database of Impella patients in our heart center and found 68 consecutive patients who underwent Impella implantation due to acute coronary syndrome (ACS) complicated by cardiogenic shock. Data were evaluated with regard to baseline and procedural characteristics and also included an assessment of the short-term and long-term outcomes. The majority of patients (74%) suffered from an ST-elevation myocardial infarction, and 59% of patients received the Impella device during the initial coronary angiography. In the remaining cases, Impella implantation was performed at a later time, most commonly after IABP implantation. Patient characteristics were not significantly different between both groups. The predominantly implanted device was an Impella 2.5. Mortality in the severely ill patient population remained high, but univariate/multivariate analyses identified significant risk factors. Interestingly, delayed initiation of Impella support was an independent predictor of higher long-term mortality (hazard ratio, 2.157; P=.04) within the Impella patient cohort. This large series of patients with ACS complicated by cardiogenic shock who underwent Impella implantation provides information on the relevant risk factors for mortality. Early (compared with delayed) initiation of Impella support was a predictor of improved survival in this population of patients.

  6. Long-term Evaluation of Peri-implant Bone Level after Reconstruction of Severely Atrophic Edentulous Maxilla via Vertical and Horizontal Guided Bone Regeneration in Combination with Sinus Augmentation: A Case Series with 1 to 15 Years of Loading.

    PubMed

    Urban, Istvan A; Monje, Alberto; Lozada, Jaime L; Wang, Hom-Lay

    2017-02-01

    To the best of the authors' knowledge, there is very limited clinical data on the outcomes of simultaneous guided bone regeneration (GBR) for horizontal and/or vertical bone gain for the reconstruction of severely atrophic edentulous maxilla. Therefore, the purpose of the clinical series presented herein was to clinically evaluate long-term horizontal and vertical bone gain, as well as implant survival rate after reconstruction of severely atrophic edentulous maxillary ridges. Sixteen patients (mean age: 64.6 ± 14.6 years of age) were consecutively treated for vertical and/or horizontal bone augmentation via GBR in combination with bilateral sinus augmentation utilizing a mixture of autologous and anorganic bovine bone. Implant survival, bone gain, intraoperative/postoperative complications and peri-implant bone loss were calculated up to the last follow-up exam. Overall, 122 dental implants were placed into augmented sites and have been followed from 12 to 180 months (mean: 76.5 months). Implant survival was 100% (satisfactory survival rate of 97.5%). Mean bone gain was 5.6 mm (max: 9 mm; min: 3 mm) While vertical bone gain was 5.1 ± 1.8 mm; horizontal bone gain was 7.0 ± 1.5 mm. No intraoperative/postoperative complications were noted. Mean peri-implant bone loss values were consistent within the standards for implant success (1.4 ± 1.0 mm). At patient-level, only one patient who had three implants presented with severe peri-implant bone loss. Complete reconstruction of an atrophied maxilla can be successfully achieved by means of guided bone regeneration for horizontal and/or vertical bone gain including bilateral sinus augmentation using a mixture of anorganic bovine bone and autologous bone. © 2016 Wiley Periodicals, Inc.

  7. Reforming long-term care financing through insurance

    PubMed Central

    Meiners, Mark R.

    1988-01-01

    Until recently, insurance for long-term care was not viewed as feasible. This perception has changed dramatically in the past few years. Several models of long-term care insurance have begun to be tested. Although the application of insurance principles to long-term care is still new, the emergence of private market interest in developing long-term care insurance has been a catalyst to renewed public-policy support for reforming the way we pay for long-term care. States, in particular, have become interested in developing public-private partnerships to support the emergence of long-term care insurance that could help relieve the mounting pressure on Medicaid budgets. PMID:10312962

  8. Somatic deleterious mutation rate in a woody plant: estimation from phenotypic data

    PubMed Central

    Bobiwash, K; Schultz, S T; Schoen, D J

    2013-01-01

    We conducted controlled crosses in populations of the long-lived clonal shrub, Vaccinium angustifolium (lowbush blueberry) to estimate inbreeding depression and mutation parameters associated with somatic deleterious mutation. Inbreeding depression level was high, with many plants failing to set fruit after self-pollination. We also compared fruit set from autogamous pollinations (pollen collected from within the same inflorescence) with fruit set from geitonogamous pollinations (pollen collected from the same plant but from inflorescences separated by several meters of branch growth). The difference between geitonogamous versus autogamous fitness within single plants is referred to as ‘autogamy depression' (AD). AD can be caused by somatic deleterious mutation. AD was significantly different from zero for fruit set. We developed a maximum-likelihood procedure to estimate somatic mutation parameters from AD, and applied it to geitonogamous and autogamous fruit set data from this experiment. We infer that, on average, approximately three sublethal, partially dominant somatic mutations exist within the crowns of the plants studied. We conclude that somatic mutation in this woody plant results in an overall genomic deleterious mutation rate that exceeds the rate measured to date for annual plants. Some implications of this result for evolutionary biology and agriculture are discussed. PMID:23778990

  9. Long-term efficacy and safety of sacral nerve stimulation for fecal incontinence.

    PubMed

    Mellgren, Anders; Wexner, Steven D; Coller, John A; Devroede, Ghislain; Lerew, Darin R; Madoff, Robert D; Hull, Tracy

    2011-09-01

    Sacral nerve stimulation is effective in the treatment of urinary incontinence and is currently under Food and Drug Administration review in the United States for fecal incontinence. Previous reports have focused primarily on short-term results of sacral nerve stimulation for fecal incontinence. The present study reports the long-term effectiveness and safety of sacral nerve stimulation for fecal incontinence in a large prospective multicenter study. Patients with fecal incontinent episodes more than twice per week were offered participation in this multicentered prospective trial. Patients showing ≥ 50% improvement during test stimulation were offered chronic implantation of the InterStim Therapy system (Medtronic; Minneapolis, MN). The aims of the current report were to provide 3-year follow-up data on patients from that study who underwent sacral nerve stimulation and were monitored under the rigors of an Food and Drug Administration-approved investigational protocol. One hundred thirty-three patients underwent test stimulation with a 90% success rate, of whom 120 (110 females) with a mean age of 60.5 years and a mean duration of fecal incontinence of 7 years received chronic implantation. Mean length of follow-up was 3.1 (range, 0.2-6.1) years, with 83 patients completing all or part of the 3-year follow-up assessment. At 3 years follow-up, 86% of patients (P < .0001) reported ≥ 50% reduction in the number of incontinent episodes per week compared with baseline and the number of incontinent episodes per week decreased from a mean of 9.4 at baseline to 1.7. Perfect continence was achieved in 40% of subjects. The therapy also improved the fecal incontinence severity index. Sacral nerve stimulation had a positive impact on the quality of life, as evidenced by significant improvements in all 4 scales of the Fecal Incontinence Quality of Life instrument at 12, 24, and 36 months of follow-up. The most common device- or therapy-related adverse events through the

  10. Management training in long-term care.

    PubMed

    Evashwick, Connie

    2002-01-01

    The education of health care administrators faces its most dramatic change since the inception of the field. Recent discussions at the national level call for major overhaul of curricula and teaching modalities, including moving education to position students for evidence-based practice. This paper presents recommendations for incorporating training about chronic and long-term care into health care management curricula. It asserts that all health care management students should have a basic knowledge of the fundamental policy, operating, and financing principles of long-term care. The majority of people using the health care delivery system today, and increasingly in the future, suffer from chronic conditions. Long-term care services, although less expansive in structure, far outnumber acute care services and health plans. They will grow in the future to meet the portending demand. To maximize job opportunities and to optimize performance in any job, health care administrators need to know about the long-term care delivery system. This paper delineates critical topics pertaining to long-term care, organized according to 11 fundamental management areas in which the field is developing core competencies. The contents were derived from a year-long process of asking stakeholders in the various facets of long-term care what topics they thought were essential for administrators to know. The topics delineated in this document represent the consensus about essential knowledge that all health care administrators should have about long-term care, whether specializing in long-term care or following a more general management career. The education of health care administrators faces its most dramatic change since the inception ofthe field. Recent discussions at the national level call for major overhaul of curricula and teaching modalities, including moving education to position students to perform according to evidence-based practice. It is thus timely to consider content, as

  11. Rehabilitation of postrior atrophic edentulous jaws: prostheses supported by 5 mm short implants or by longer implants in augmented bone? One-year results from a pilot randomised clinical trial.

    PubMed

    Esposito, Marco; Pellegrino, Gerardo; Pistilli, Roberto; Felice, Pietro

    2011-01-01

    To evaluate whether 5 mm short dental implants could be an alternative to augmentation with anorganic bovine bone and placement of at least 10 mm long implants in posterior atrophic jaws. Fifteen patients with bilateral atrophic mandibles (5-7 mm bone height above the mandibular canal), and 15 patients with bilateral atrophic maxillae (4-6 mm bone height below the maxillary sinus) and bone thickness of at least 8 mm, were randomised according to a splitmouth design to receive one to three 5 mm short implants or at least 10 mm long implants in augmented bone. Mandibles were vertically augmented with interpositional bone blocks and maxillary sinuses with particulated bone via a lateral window. Implants were placed after 4 months, submerged and loaded, after 4 months, with provisional prostheses. Four months later, definitive provisionally cemented prostheses were delivered. Outcome measures were: prosthesis and implant failures, any complication and peri-implant marginal bone level changes. In 5 augmented mandibles, the planned 10 mm long implants could not be placed and shorter implants (7 and 8.5 mm) had to be used instead. One year after loading no patient dropped out. Two long (8.5 mm in the mandible and 13 mm in the maxilla) implants and one 5 mm short maxillary implant failed. There were no statistically significant differences in failures or complications. Patients with short implants lost on average 1 mm of peri-implant bone and patients with longer implants lost 1.2 mm. This difference was statistically significant. This pilot study suggests that 1 year after loading, 5 mm short implants achieve similar if not better results than longer implants placed in augmented bone. Short implants might be a preferable choice to bone augmentation since the treatment is faster, cheaper and associated with less morbidity, however their long-term prognosis is unknown.

  12. Placenta previa and long-term morbidity of the term offspring.

    PubMed

    Walfisch, Asnat; Beharier, Ofer; Shoham-Vardi, Ilana; Sergienko, Ruslan; Landau, Daniella; Sheiner, Eyal

    2016-08-01

    The long-term impact of placenta previa on term infants is unknown. We aimed to investigate whether abnormal placentation increases the risk for long-term morbidity of the term offspring. A population-based cohort study compared the incidence of long-term hospitalizations up to the age of 18 due to cardiovascular, endocrine, neurological, hematological, respiratory and urinary morbidity of children born at term in pregnancies diagnosed with placenta previa and those without. Deliveries occurred between the years 1991-2013 in a tertiary medical center. Multiple pregnancies, and fetal congenital malformations were excluded. Kaplan-Meier survival curves were used to compare cumulative morbidity incidence over time. A multivariable generalized estimating equation (GEE) logistic regression model analysis was used to control for confounders and for maternal clusters. During the study period 233,123 term deliveries met the inclusion criteria; 0.2% (n=502) of the children were born to mothers with placenta previa. During the follow-up period, children born to mothers with placenta previa did not have an increased risk for long-term cardiovascular, endocrine, hematological, neurological, respiratory, and urinary morbidity. Term offsprings of mothers diagnosed with placenta previa do not appear to be at an increased risk for long-term morbidity up to the age of 18. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  13. Long-term, hormone-responsive organoid cultures of human endometrium in a chemically defined medium.

    PubMed

    Turco, Margherita Y; Gardner, Lucy; Hughes, Jasmine; Cindrova-Davies, Tereza; Gomez, Maria J; Farrell, Lydia; Hollinshead, Michael; Marsh, Steven G E; Brosens, Jan J; Critchley, Hilary O; Simons, Benjamin D; Hemberger, Myriam; Koo, Bon-Kyoung; Moffett, Ashley; Burton, Graham J

    2017-05-01

    In humans, the endometrium, the uterine mucosal lining, undergoes dynamic changes throughout the menstrual cycle and pregnancy. Despite the importance of the endometrium as the site of implantation and nutritional support for the conceptus, there are no long-term culture systems that recapitulate endometrial function in vitro. We adapted conditions used to establish human adult stem-cell-derived organoid cultures to generate three-dimensional cultures of normal and decidualized human endometrium. These organoids expand long-term, are genetically stable and differentiate following treatment with reproductive hormones. Single cells from both endometrium and decidua can generate a fully functional organoid. Transcript analysis confirmed great similarity between organoids and the primary tissue of origin. On exposure to pregnancy signals, endometrial organoids develop characteristics of early pregnancy. We also derived organoids from malignant endometrium, and so provide a foundation to study common diseases, such as endometriosis and endometrial cancer, as well as the physiology of early gestation.

  14. Long-term, hormone-responsive organoid cultures of human endometrium in a chemically-defined medium

    PubMed Central

    Turco, Margherita Y.; Gardner, Lucy; Hughes, Jasmine; Cindrova-Davies, Tereza; Gomez, Maria J.; Farrell, Lydia; Hollinshead, Michael; Marsh, Steven G.E.; Brosens, Jan J.; Critchley, Hilary O.; Simons, Benjamin D.; Hemberger, Myriam; Koo, Bon-Kyoung; Moffett, Ashley; Burton, Graham J.

    2017-01-01

    In humans, the endometrium, the uterine mucosal lining, undergoes dynamic changes throughout the menstrual cycle and pregnancy. Despite the importance of the endometrium as the site of implantation and nutritional support for the conceptus, there are no long-term culture systems that recapitulate endometrial function in vitro. We adapted conditions used to establish human adult stem cell-derived organoid cultures to generate 3D cultures of normal and decidualised human endometrium. These organoids expand long-term, are genetically stable and differentiate following treatment with reproductive hormones. Single cells from both endometrium and decidua can generate a fully functional organoid. Transcript analysis confirmed great similarity between organoids and the primary tissue of origin. On exposure to pregnancy signals, endometrial organoids develop characteristics of early pregnancy. We also derived organoids from malignant endometrium, and so provide a foundation to study common diseases, such as endometriosis and endometrial cancer, as well as the physiology of early gestation. PMID:28394884

  15. Optical power transfer and communication methods for wireless implantable sensing platforms.

    PubMed

    Mujeeb-U-Rahman, Muhammad; Adalian, Dvin; Chang, Chieh-Feng; Scherer, Axel

    2015-09-01

    Ultrasmall scale implants have recently attracted focus as valuable tools for monitoring both acute and chronic diseases. Semiconductor optical technologies are the key to miniaturizing these devices to the long-sought sub-mm scale, which will enable long-term use of these devices for medical applications. This can also enable the use of multiple implantable devices concurrently to form a true body area network of sensors. We demonstrate optical power transfer techniques and methods to effectively harness this power for implantable devices. Furthermore, we also present methods for optical data transfer from such implants. Simultaneous use of these technologies can result in miniaturized sensing platforms that can allow for large-scale use of such systems in real world applications.

  16. Optical power transfer and communication methods for wireless implantable sensing platforms

    NASA Astrophysics Data System (ADS)

    Mujeeb-U-Rahman, Muhammad; Adalian, Dvin; Chang, Chieh-Feng; Scherer, Axel

    2015-09-01

    Ultrasmall scale implants have recently attracted focus as valuable tools for monitoring both acute and chronic diseases. Semiconductor optical technologies are the key to miniaturizing these devices to the long-sought sub-mm scale, which will enable long-term use of these devices for medical applications. This can also enable the use of multiple implantable devices concurrently to form a true body area network of sensors. We demonstrate optical power transfer techniques and methods to effectively harness this power for implantable devices. Furthermore, we also present methods for optical data transfer from such implants. Simultaneous use of these technologies can result in miniaturized sensing platforms that can allow for large-scale use of such systems in real world applications.

  17. Consider long-term care as service alternative.

    PubMed

    Loria, L S

    1987-04-01

    The increasing demand for elderly care services, pressures on inpatient average length of stay and payment levels, and potential financial rewards from providing additional services, makes long-term care look attractive to hospitals. Long-term care, however, is not for every hospital. Before deciding to establish long-term care services, management should examine how the service fits within the hospital's strategic plan. The action plan below provides guidance in evaluating a decision to use hospital facilities for long-term care. Examine how long-term care services fit within the hospital's strategic plan. Study area demographics and competitors to assess the need and supply of long-term care services. Survey the medical staff, consumers and payers to determine attitudes, perceptions and interests regarding long-term care services. Develop a facility plan that identifies areas of excess capacity that can be most easily converted into long-term care with minimal effects on hospital operations. Prepare a financial feasibility analysis of the contribution margin and return on investment attributable to long-term care services. Include an impact analysis on hospital operations. Establish a management task force to develop a detailed implementation plan including assigned individual responsibilities and related timetable. Develop an effective marketing plan designed to generate increased patient market share.

  18. Long-term data archiving

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moore, David Steven

    2009-01-01

    Long term data archiving has much value for chemists, not only to retain access to research and product development records, but also to enable new developments and new discoveries. There are some recent regulatory requirements (e.g., FDA 21 CFR Part 11), but good science and good business both benefit regardless. A particular example of the benefits of and need for long term data archiving is the management of data from spectroscopic laboratory instruments. The sheer amount of spectroscopic data is increasing at a scary rate, and the pressures to archive come from the expense to create the data (or recreatemore » it if it is lost) as well as its high information content. The goal of long-term data archiving is to save and organize instrument data files as well as any needed meta data (such as sample ID, LIMS information, operator, date, time, instrument conditions, sample type, excitation details, environmental parameters, etc.). This editorial explores the issues involved in long-term data archiving using the example of Raman spectral databases. There are at present several such databases, including common data format libraries and proprietary libraries. However, such databases and libraries should ultimately satisfy stringent criteria for long term data archiving, including readability for long times into the future, robustness to changes in computer hardware and operating systems, and use of public domain data formats. The latter criterion implies the data format should be platform independent and the tools to create the data format should be easily and publicly obtainable or developable. Several examples of attempts at spectral libraries exist, such as the ASTM ANDI format, and the JCAMP-DX format. On the other hand, proprietary library spectra can be exchanged and manipulated using proprietary tools. As the above examples have deficiencies according to the three long term data archiving criteria, Extensible Markup Language (XML; a product of the World Wide

  19. Long-Term Control Medications for Lung Diseases

    MedlinePlus

    ... Asthma Medications Long-Term Control Medications Long-Term Control Medications Make an Appointment Ask a Question Refer Patient Long-term control medications are taken daily to control and prevent ...

  20. Implant failure in lower limb long bone diaphyseal fractures at a tertiary hospital in Ile- Ife. Nigeria.

    PubMed

    Esan, O; Ikem, I C; Orimolade, E A; Esan, O T

    2014-06-01

    This included determining aetiology of failure and comparing the failure rate in implant fixations using solid intramedullary nail and DCP. A retrospective study conducted at the Orthopaedic Department, Obafemi Awolowo University Teaching Hospital, Ile-Ife,Nigeria. Records of all operated cases of lower limb long bone diaphyseal fractures including those with failed fixations from August 2006-July 2011 were reviewed. Data retrieved included type of implant used, aetiology and characteristics of Implant failure. Data were analysed using SPSS version 16. Frequency distribution of the variables of interest was done. Difference in failure rate of intramedullary nail versus DCP was tested using chi-square. Statistical significance was inferred at p<0.05. A total of 280 patients were studied out of which two hundred and twenty-one patients had long bone diaphyseal fractures and met inclusion criteria, of which 135 had intramedullary nail fixation and 86 had DCP. The rate of implant failure in intramedullary nail was 1.5% while it was 5.8% in patients with DCP (p=0.113; 0R=4.10; 95% CI=0.65- 43.77). Implant fracture was the commonest type of failure seen (100% versus 60%) and non union was the commonest cause of failure seen (50% versus 40%) in the intramedullary nailing and DCP groups respectively. The likelihood of a failed implant is higher in fixations done with DCP compared with intramedullary nail though the difference was not statistically significant. Commonest reason for failure in both groups was non-union. Findings from this study may guide surgeons in choice of implant in the management of long bone fractures.

  1. Clinical Validation of a Sound Processor Upgrade in Direct Acoustic Cochlear Implant Subjects

    PubMed Central

    Kludt, Eugen; D’hondt, Christiane; Lenarz, Thomas; Maier, Hannes

    2017-01-01

    Objective: The objectives of the investigation were to evaluate the effect of a sound processor upgrade on the speech reception threshold in noise and to collect long-term safety and efficacy data after 2½ to 5 years of device use of direct acoustic cochlear implant (DACI) recipients. Study Design: The study was designed as a mono-centric, prospective clinical trial. Setting: Tertiary referral center. Patients: Fifteen patients implanted with a direct acoustic cochlear implant. Intervention: Upgrade with a newer generation of sound processor. Main Outcome Measures: Speech recognition test in quiet and in noise, pure tone thresholds, subject-reported outcome measures. Results: The speech recognition in quiet and in noise is superior after the sound processor upgrade and stable after long-term use of the direct acoustic cochlear implant. The bone conduction thresholds did not decrease significantly after long-term high level stimulation. Conclusions: The new sound processor for the DACI system provides significant benefits for DACI users for speech recognition in both quiet and noise. Especially the noise program with the use of directional microphones (Zoom) allows DACI patients to have much less difficulty when having conversations in noisy environments. Furthermore, the study confirms that the benefits of the sound processor upgrade are available to the DACI recipients even after several years of experience with a legacy sound processor. Finally, our study demonstrates that the DACI system is a safe and effective long-term therapy. PMID:28406848

  2. Implant-Abutment Contact Surfaces and Microgap Measurements of Different Implant Connections Under 3-Dimensional X-Ray Microtomography.

    PubMed

    Scarano, Antonio; Valbonetti, Luca; Degidi, Marco; Pecci, Raffaella; Piattelli, Adriano; de Oliveira, P S; Perrotti, Vittoria

    2016-10-01

    The presence of a microgap between implant and abutment could produce a bacterial reservoir which could interfere with the long-term health of the periimplant tissues. The aim of this article was to evaluate, by x-ray 3-dimensional microtomography, implant-abutment contact surfaces and microgaps at the implant-abutment interface in different types of implant-abutment connections. A total of 40 implants were used in this in vitro study. Ten implants presented a screw-retained internal hexagon abutment (group I), 10 had a Morse Cone taper internal connection (group II), 10 another type of Morse Cone taper internal connection (group III), and 10 had a screwed trilobed connection (group IV). In both types of Morse Cone internal connections, there was no detectable separation at the implant-abutment in the area of the conical connection, and there was an absolute congruity without any microgaps between abutment and implant. No line was visible separating the implant and the abutment. On the contrary, in the screwed abutment implants, numerous gaps and voids were present. The results of this study support the hypothesis that different types of implant-abutment joints are responsible for the observed differences in bacterial penetration.

  3. Reforming Long-Term Care Funding in Alberta.

    PubMed

    Crump, R Trafford; Repin, Nadya; Sutherland, Jason M

    2015-01-01

    Like many provinces across Canada, Alberta is facing growing demand for long-term care. Issues with the mixed funding model used to pay long-term care providers had Alberta Health Services concerned that it was not efficiently meeting the demand for long-term care. Consequently, in 2010, Alberta Health Services introduced the patient/care-based funding (PCBF) model. PCBF is similar to activity-based funding in that it directly ties the complexity and care needs of long-term care residents to the payment received by long-term care providers. This review describes PCBF and discusses some of its strengths and weaknesses. In doing so, this review is intended to inform other provinces faced with similar long-term care challenges and contemplating their own funding reforms.

  4. Long-term follow-up of borderline ovarian tumors clinical outcome and prognostic factors.

    PubMed

    Lazarou, Anastasia; Fotopoulou, Christina; Coumbos, Alexandra; Sehouli, Jalid; Vasiljeva, Jekaterina; Braicu, Ioana; Burger, Heinz; Kuehn, Wolfgang

    2014-11-01

    The aim of the present study was to evaluate the characteristics of borderline ovarian tumors (BOTs). Data of 151 patients with BOTs were retrospectively evaluated. A total of 151 cases with BOTs were diagnosed. Histopathological evaluation identified 82.8% with serous, 10.6% with mucinous and 5.3% with mixed histology. Overall, 67.5% had International Federation of Gynecology and Obstetrics (FIGO) stage I, 10.6% FIGO stage II, 14.6% FIGO stage III and 4% FIGO stage IV. A total of 21.9% had peritoneal implants; of which 2.7% were invasive, 17.2% non-invasive and 2% both invasive and non-invasive. Microinvasion was observed in 5.3% and a micropapillary pattern in 12.6%. A total of 12.6% of patients presented second neoplasms. During a median follow-up period of 86 (range=0.1-432) months, there were relapses in 16.8%, of which 52.6% had invasive implants. Overall, 6.2% died of their disease, 28.5% with invasive implants. The median time-to-progression was 48 (range=8-120) months. Patients with BOTs have an excellent prognosis. Long-term follow-up is recommended, since recurrence occurs. Copyright© 2014 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  5. Assessment of gliosis around moveable implants in the brain

    PubMed Central

    Stice, Paula

    2010-01-01

    Repositioning microelectrodes post-implantation is emerging as a promising approach to achieve long-term reliability in single neuronal recordings. The main goal of this study was to (a) assess glial reaction in response to movement of microelectrodes in the brain post-implantation and (b) determine an optimal window of time post-implantation when movement of microelectrodes within the brain would result in minimal glial reaction. Eleven Sprague-Dawley rats were implanted with two microelectrodes each that could be moved in vivo post-implantation. Three cohorts were investigated: (1) microelectrode moved at day 2 (n = 4 animals), (2) microelectrode moved at day 14 (n = 5 animals) and (3) microelectrode moved at day 28 (n = 2 animals). Histological evaluation was performed in cohorts 1–3 at four-week post-movement (30 days, 42 days and 56 days post-implantation, respectively). In addition, five control animals were implanted with microelectrodes that were not moved. Control animals were implanted for (1) 30 days (n = 1), (2) 42 days (n = 2) and (3) 56 days (n = 2) prior to histological evaluation. Quantitative assessment of glial fibrillary acidic protein (GFAP) around the tip of the microelectrodes demonstrated that GFAP levels were similar around microelectrodes moved at day 2 when compared to the 30-day controls. However, GFAP expression levels around microelectrode tips that moved at day 14 and day 28 were significantly less than those around control microelectrodes implanted for 42 and 56 days, respectively. Therefore, we conclude that moving microelectrodes after implantation is a viable strategy that does not result in any additional damage to brain tissue. Further, moving the microelectrode downwards after 14 days of implantation may actually reduce the levels of GFAP expression around the tips of the microelectrodes in the long term. PMID:19556680

  6. Long-Term Survival of Dental Implants with Different Prosthetic Loading Times in Healthy Patients: A 5-Year Retrospective Clinical Study.

    PubMed

    Muelas-Jiménez, M Isabel; Olmedo-Gaya, Maria Victoria; Manzano-Moreno, Francisco J; Reyes-Botella, Candela; Vallecillo-Capilla, Manuel

    2017-02-01

    To compare survival rates among dental implants restored with immediate, early, and conventional loading protocols, also comparing between maxillary and mandibular implants, and to evaluate the influence of implant length and diameter and the type of prosthesis on treatment outcomes. This retrospective cohort study initially included all 52 patients receiving dental implants between July 2006 and February 2008 at a private oral surgery clinic in Granada (Southern Spain). Clinical and radiographic examinations were performed, including periapical or panoramic radiographs, and incidences during completion of the restoration were recorded at 1 week, 3 months, 6 months, and at 1, 2, 3, 4, and 5 years. After a 5-year follow-up, 1 patient had died, 3 were lost to follow-up, and 6 required grafting before implant placement; therefore, the final study sample comprised 42 patients with 164 implants. Variables associated with the survival/failure of the restoration were: number of implants (higher failure rate with fewer implants), bone type (higher failure rate in type III or IV bone), and type of prosthesis (higher failure rate with single crowns). No significant association was found in univariate or multivariate analyses between survival rate and the loading protocol, implant length or diameter, or maxillary/mandibular location. Immediate occlusal loading, immediate provisionalization without occlusal loading, and early loading are viable treatment options with similar survival rates to those obtained with conventional loading. Bone quality and number of implants per patient were the most influential factors. © 2015 by the American College of Prosthodontists.

  7. Clinical long-term outcome of septal myectomy for obstructive hypertrophic cardiomyopathy in infants.

    PubMed

    Schleihauf, Julia; Cleuziou, Julie; Pabst von Ohain, Jelena; Meierhofer, Christian; Stern, Heiko; Shehu, Nerejda; Mkrtchyan, Naira; Kaltenecker, Emanuel; Kühn, Andreas; Nagdyman, Nicole; Hager, Alfred; Seidel, Heide; Lange, Rüdiger; Ewert, Peter; Wolf, Cordula M

    2018-03-01

    Surgical septal myectomy is performed to relieve left ventricular outflow tract narrowing in severe drug-refractory obstructive hypertrophic cardiomyopathy. The objective of this study was to assess the perioperative and long-term clinical outcome of this procedure performed during infancy. Clinical, transthoracic echocardiographic, electrocardiographic, 24-h Holter, cardiopulmonary exercise test and genetic data were extracted by medical record review. A subset of patients underwent additional prospective detailed clinical evaluation including cardiac magnetic resonance imaging with contrast. Surgery was performed in 23 paediatric patients between 1978 and 2015 at the German Heart Centre Munich. Twelve patients had undergone surgery during infancy (≤ 1 year) (Group A), 11 between 1 and 18 years of age (Group B). The underlying genetic diagnosis was Noonan syndrome spectrum and non-syndromic hypertrophic cardiomyopathy. As compared to Group B, patients in Group A showed more concomitant cardiac procedures and received more homologous transfusions. One perioperative death occurred in Group A, and none in Group B. Two patients in Group A but no patient in Group B required redo septal myectomy. The long-term clinical outcome was similar between the 2 groups. One patient in Group B required cardioverter-defibrillator/pacemaker implantation for higher degree atrioventricular block and none in Group A. There was no evidence of differences in myocardial fibrosis between groups on long-term follow-up magnetic resonance imaging. Surgical septal myectomy can be performed safely during infancy with favourable perioperative and long-term clinical outcome but with a trend towards a higher reoperation rate later in life. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  8. Personalised long-term follow-up of cochlear implant patients using remote care, compared with those on the standard care pathway: study protocol for a feasibility randomised controlled trial

    PubMed Central

    Kitterick, Padraig; DeBold, Lisa; Weal, Mark; Clarke, Nicholas; Newberry, Eva; Aubert, Lisa

    2016-01-01

    Introduction Many resources are required to provide postoperative care to patients who receive a cochlear implant. The implant service commits to lifetime follow-up. The patient commits to regular adjustment and rehabilitation appointments in the first year and annual follow-up appointments thereafter. Offering remote follow-up may result in more stable hearing, reduced patient travel expense, time and disruption, more empowered patients, greater equality in service delivery and more freedom to optimise the allocation of clinic resources. Methods and analysis This will be a two-arm feasibility randomised controlled trial (RCT) involving 60 adults using cochlear implants with at least 6 months device experience in a 6-month clinical trial of remote care. This project will design, implement and evaluate a person-centred long-term follow-up pathway for people using cochlear implants offering a triple approach of remote and self-monitoring, self-adjustment of device and a personalised online support tool for home speech recognition testing, information, self-rehabilitation, advice, equipment training and troubleshooting. The main outcome measure is patient activation. Secondary outcomes are stability and quality of hearing, stability of quality of life, clinic resources, patient and clinician experience, and any adverse events associated with remote care. We will examine the acceptability of remote care to service users and clinicians, the willingness of participants to be randomised, and attrition rates. We will estimate numbers required to plan a fully powered RCT. Ethics and dissemination Ethical approval was received from North West—Greater Manchester South Research Ethics Committee (15/NW/0860) and the University of Southampton Research Governance Office (ERGO 15329). Results Results will be disseminated in the clinical and scientific communities and also to the patient population via peer-reviewed research publications both online and in print, conference and

  9. Personalised long-term follow-up of cochlear implant patients using remote care, compared with those on the standard care pathway: study protocol for a feasibility randomised controlled trial.

    PubMed

    Cullington, Helen; Kitterick, Padraig; DeBold, Lisa; Weal, Mark; Clarke, Nicholas; Newberry, Eva; Aubert, Lisa

    2016-05-13

    Many resources are required to provide postoperative care to patients who receive a cochlear implant. The implant service commits to lifetime follow-up. The patient commits to regular adjustment and rehabilitation appointments in the first year and annual follow-up appointments thereafter. Offering remote follow-up may result in more stable hearing, reduced patient travel expense, time and disruption, more empowered patients, greater equality in service delivery and more freedom to optimise the allocation of clinic resources. This will be a two-arm feasibility randomised controlled trial (RCT) involving 60 adults using cochlear implants with at least 6 months device experience in a 6-month clinical trial of remote care. This project will design, implement and evaluate a person-centred long-term follow-up pathway for people using cochlear implants offering a triple approach of remote and self-monitoring, self-adjustment of device and a personalised online support tool for home speech recognition testing, information, self-rehabilitation, advice, equipment training and troubleshooting. The main outcome measure is patient activation. Secondary outcomes are stability and quality of hearing, stability of quality of life, clinic resources, patient and clinician experience, and any adverse events associated with remote care. We will examine the acceptability of remote care to service users and clinicians, the willingness of participants to be randomised, and attrition rates. We will estimate numbers required to plan a fully powered RCT. Ethical approval was received from North West-Greater Manchester South Research Ethics Committee (15/NW/0860) and the University of Southampton Research Governance Office (ERGO 15329). Results will be disseminated in the clinical and scientific communities and also to the patient population via peer-reviewed research publications both online and in print, conference and meeting presentations, posters, newsletter articles, website reports

  10. Long-term follow-up of bulking agents for stress urinary incontinence in older patients.

    PubMed

    Plotti, Francesco; Montera, Roberto; Terranova, Corrado; Luvero, Daniela; Marrocco, Francesca; Miranda, Andrea; Gatti, Alessandra; De Cicco Nardone, Carlo; Angioli, Roberto; Scaletta, Giuseppe

    2018-06-01

    Implantation of bulking agents represents a noninvasive procedure for the treatment of stress urinary incontinence (SUI) in all patients where a more invasive procedure may increase perioperative risks. The primary aim of this retrospective study was to evaluate the efficacy over time of bulking agent implantation. As secondary aims, we evaluated long-term (patients' subjective) satisfaction rate, rate of de novo urinary symptoms, and the impact of urinary incontinence on the quality of life. All patients who underwent implantation of bulking agents between 1999 and 2013 at Campus Bio-Medico of Rome were retrospectively considered eligible for this study. Patients were interviewed using two standardized questionnaires: International Consultation on Incontinence Questionnaire Short Form and Patient Global Impression of Improvement. Cure rate, improvement rate, failure rate, and the onset of new symptoms were also investigated through specific questions. The original group of patients was then divided into two subgroups according to follow-up time (group A: shorter than median follow-up; group B: longer than median follow-up). Sixty-three patients were enrolled. Mean follow-up was 8.3 ± 3.5 years with a range of 3.5 to 18 years. Fifteen (24%) cured patients (cure rate), 12 (19%) improved patients (improvement rate), 36 (57%) failed treatment (failure rate). We reported an overall success rate of 43%. No differences were reported among groups in terms of overall success rate (42% vs 44% for group A and group B, respectively). Bulking agent implantation is an effective treatment for people with intrinsic sphincter deficiency (type III SUI) and it is a valid alternative to more invasive surgeries in older patients. Moreover, it shows an overall success rate (43%) that remains high even after many years.

  11. Optical methods for wireless implantable sensing platforms

    NASA Astrophysics Data System (ADS)

    Mujeeb-U-Rahman, Muhammad; Chang, Chieh-Feng; Scherer, Axel

    2013-09-01

    Ultra small scale implants have gained lots of importance for both acute and chronic applications. Optical techniques hold the key to miniaturizing these devices to long sought sub-mm scale. This will lead towards long term use of these devices for medically relevant applications. It can also allow using multiple of these devices at the same time and forming a true body area network of sensors. In this paper, we present optical power transfer to such devices and the techniques to harness this power for different applications, for example high voltage or high current applications. We also present methods for wireless data transfer from such implants.

  12. Combined trabeculotomy-trabeculectomy versus Ahmed valve implantation for refractory primary congenital glaucoma in Egyptian patients: a long-term follow-up

    PubMed Central

    Helmy, Hazem

    2016-01-01

    .3 postoperatively in group 2. The success rate in group 1 was 97, 91, 76, and 61% in years 1, 2, 3, and 4, respectively, whereas the success rate in group 2 was 97, 93, 81, and 66% in years 1, 2, 3, and 4, respectively. Conclusion Both procedures, i.e., combined trabeculotomy-trabeculectomy and Ahmed valve implantation are suitable options in advanced PCG with failed trabeculotomy and goniotomy. Ahmed valve implanation has a better long-term survival, but trabeculotomy-trabeculectomy provides a second chance for surgical intervention. PMID:27053995

  13. A retrospective study on clinical and radiological outcomes of oral implants in patients followed up for a minimum of 20 years.

    PubMed

    Chrcanovic, Bruno Ramos; Kisch, Jenö; Albrektsson, Tomas; Wennerberg, Ann

    2018-04-01

    Very long-term follow-up of oral implants is seldom reported in the literature. To assess oral implant failure rates and marginal bone loss (MBL) of patients followed up for a minimum of 20 years. Implants placed in patients followed up for 20+ years were included. Descriptive statistics, survival analyses, generalized estimating equations were performed. Three-hundred implants were randomly selected for MBL. 1,045 implants (227 patients) were included. Implant location, irradiation, and bruxism affected the implant survival rate. Thirty-five percent of the failures occurred within the first year after implantation, and another 26.8% in the second/third year. There was a cumulative survival rate of 87.8% after 36 years of follow-up. In the last radiological follow up, 35 implants (11.7%) had bone gain, and 35 implants (11.7%) presented at least 3 mm of MBL. Twenty-six out of 86 failed implants with available radiograms presented severe MBL in the last radiological register before implant failure. Most of the implant failures occurred at the first few years after implantation, regardless of a very long follow up. MBL can be insignificant in long-term observations, but it may, nevertheless, be the cause of secondary failure of oral implants in some cases. © 2017 Wiley Periodicals, Inc.

  14. Effects of long-term corticosterone implants on growth and immune function in juvenile alligators, Alligator mississippiensis.

    PubMed

    Morici, L A; Elsey, R M; Lance, V A

    1997-10-01

    Sixty juvenile alligators were implanted subcutaneously with slow release pellets of corticosterone or placebo. Alligators were divided into five different groups such that each group received a different dose. A blood sample was taken prior to and 4 days after the implants were in place to measure hormone levels. Additional blood samples were collected at 1 month and 3 months. At 4 days corticosterone levels ranged from 3,400 ng/ml in the group treated with the high dose to 40 ng/ml in the group implanted with the low dose. The extremely high dose caused 40% mortality within 4 weeks. It was evident that the pellets did not release the hormone for the expected 90 days. Circulating levels of corticosterone were back to baseline levels by 3 months. Hormone levels achieved at 4 days were a reliable predictor of subsequent growth. Rate of growth was negatively correlated with plasma corticosterone at 4 days (r2 = 0.711) and at 1 month (r2 = 0.544) posttreatment. Differential white blood cell counts performed after 1 month of treatment showed a clear effect of the implant. Alligators treated with corticosterone had decreased percentages of lymphocytes, eosinophils, and basophils and had a higher heterophil/lymphocyte (H/L) ratio than the placebo group. Furthermore, histological examination of the spleen revealed a significant depletion of lymphoid cells in alligators treated with the highest dose of hormone. The results from this study demonstrate that exogenous corticosterone can mimic the effects of prolonged stress in juvenile alligators.

  15. Biocompatibility Assessment of a Long-Term Wearable Artificial Pump-Lung in Sheep

    PubMed Central

    Zhou, Kang; Niu, Shuqiong; Bianchi, Giacomo; Wei, Xufeng; Garimella, Narayana; Griffith, Bartley P; Wu, Zhongjun J

    2013-01-01

    The purpose of this study was to assess the biocompatibility of a newly developed long-term wearable artificial pump-lung (APL) in a clinically relevant ovine animal mode. The wearable APL device was implanted in five sheep through a left thoracotomy. The device was connected between the right atrium (RA) and pulmonary artery (PA) and evaluated for 30 days. Three sheep were used as the sham control. Platelet activation was assessed by measuring platelet surface P-selectin (CD62P) expression with flow cytometry and plasma soluble P-selectin with an enzyme-linked immunosorbent assay (ELISA). Thrombotic deposition on the device components and hollow fiber membranes (HFM) were analyzed with digital imaging and scanning electron microscopy (SEM). Surface P-selectin of the APL and sham groups changed significantly over the study period, but without significant differences between the two groups. Soluble P-selectin for the two groups peaked in the first 24 hours after the surgery. Soluble P-selectin of the APL group remained slightly elevated over the study period compared to the pre-surgical baseline value and was slightly higher compared to that of the sham group. Plasma free hemoglobin (PFH) remained in the normal ranges in all the animals. In spite of the surgery related alteration in laboratory tests and elevation of platelet activation status, the APL devices in all the animals functioned normally (oxygen transfer and blood pumping) during the 30 day study period. The device flow path and membrane surface were free of gross thrombus. Electron microscopy images showed only scattered thrombi on the fibers (membrane surface and weft). In summary, the APL exhibited excellent biocompatibility. Two forms of platelet activation, surgery related and device induced, in the animals implanted with the wearable APL were observed. The limited device-induced platelet activation did not cause gross thrombosis and impair the long-term device performance. PMID:23452221

  16. The Long-Term Budget Outlook

    DTIC Science & Technology

    2005-12-01

    Revenues Under CBO’s Long-Term Budget Scenarios 56A-8. Real Gross Domestic Product Under CBO’s Long-Term Budget Scenarios 57A-9. Total Surplus or...scenarios suggest that total federal spending for Medicare and Medicaid in 2050 could range anywhere from 7 percent of gross domestic product (GDP)—a...see the Congressional Budget Office’s glossary of budgetary and economic terms, available at www.cbo.gov. 2. The future path of productivity growth

  17. Development of a cell-based treatment for long-term neurotrophin expression and spiral ganglion neuron survival.

    PubMed

    Zanin, M P; Hellström, M; Shepherd, R K; Harvey, A R; Gillespie, L N

    2014-09-26

    Spiral ganglion neurons (SGNs), the target cells of the cochlear implant, undergo gradual degeneration following loss of the sensory epithelium in deafness. The preservation of a viable population of SGNs in deafness can be achieved in animal models with exogenous application of neurotrophins such as brain-derived neurotrophic factor (BDNF) and neurotrophin-3. For translation into clinical application, a suitable delivery strategy that provides ongoing neurotrophic support and promotes long-term SGN survival is required. Cell-based neurotrophin treatment has the potential to meet the specific requirements for clinical application, and we have previously reported that Schwann cells genetically modified to express BDNF can support SGN survival in deafness for 4 weeks. This study aimed to investigate various parameters important for the development of a long-term cell-based neurotrophin treatment to support SGN survival. Specifically, we investigated different (i) cell types, (ii) gene transfer methods and (iii) neurotrophins, in order to determine which variables may provide long-term neurotrophin expression and which, therefore, may be the most effective for supporting long-term SGN survival in vivo. We found that fibroblasts that were nucleofected to express BDNF provided the most sustained neurotrophin expression, with ongoing BDNF expression for at least 30 weeks. In addition, the secreted neurotrophin was biologically active and elicited survival effects on SGNs in vitro. Nucleofected fibroblasts may therefore represent a method for safe, long-term delivery of neurotrophins to the deafened cochlea to support SGN survival in deafness. Copyright © 2014 IBRO. Published by Elsevier Ltd. All rights reserved.

  18. Bilateral Sequential Cochlear Implantation in Patients With Enlarged Vestibular Aqueduct (EVA) Syndrome.

    PubMed

    Manzoor, Nauman F; Wick, Cameron C; Wahba, Marian; Gupta, Amit; Piper, Robin; Murray, Gail S; Otteson, Todd; Megerian, Cliff A; Semaan, Maroun T

    2016-02-01

    To analyze audiometric outcomes after bilateral cochlear implantation in patients with isolated enlarged vestibular aqueduct (EVA) syndrome and associated incomplete partition (IP) malformations. Secondary objective was to analyze rate of cerebrospinal fluid (CSF) gusher in patients with IP-EVA spectrum deformities and compare this with the existing literature. Retrospective chart review. Thirty-two patients with EVA syndrome who received unilateral or bilateral cochlear implants between June 1999 and January 2014 were identified in the University Hospitals Case Medical Center cochlear implant database. Isolated EVA (IEVA) and Incomplete Partition Type II (IP-II) malformations were identified by reviewing high-resolution computed tomography (HRCT) imaging. Demographic information, age at implantation, surgical details, postimplantation audiometric data including speech reception thresholds (SRT), word, and sentence scores were reviewed and analyzed. Intra- and postoperative complications were analyzed as well and compared with the literature. Seventeen patients (32 implanted ears) had pediatric cochlear implantation for EVA-associated hearing loss. Data from 16 controls (32 implanted ears) were used to compare audiometric and speech outcomes of EVA cohort. Mean age at implantation was 6.8 years for EVA cohort and 6.0 years for controls. There was no statistically significant difference in long-term postoperative SRT, monaurally aided word scores, and binaurally tested word scores between pediatric EVA group and controls. The EVA patients had a long-term mean sentence score of 85.92%. A subset of EVA patients implanted at mean age of 3.18 years (n = 15 ears) had similar audiometric outcomes to another control group with Connexin 26 mutations (n = 20 ears) implanted at a similar age. Further subset analysis revealed no significant differences in age at implantation, SRT, and word scores in patients with IEVA and IP-II malformation. There was no significant

  19. Renal Function Changes Following Left Ventricular Assist Device Implantation.

    PubMed

    Daimee, Usama A; Wang, Meng; Papernov, Anna; Sherazi, Saadia; McNitt, Scott; Vidula, Himabindu; Chen, Leway; Alexis, Jeffrey D; Kutyifa, Valentina

    2017-12-15

    Limited data assessing the clinical significance of post-left ventricular assist device (LVAD) in renal function are available. We aimed to investigate the impact of changes in renal function after LVAD implantation on subsequent long-term outcomes. We followed 184 patients with HeartMate II LVADs implanted between May 2008 and November 2014. Serial assessment of renal function, was performed at baseline and at day 1, day 7, 1 month, 3 months, 6 months, 1 year, and 2 years after implantation. Effects of 1-month GFR and changes in GFR from baseline to 1 month on long-term mortality and hospital re-admission were evaluated. There were 30 patients with GFR <45 (low), 44 with GFR 45 to 59 (intermediate), and 110 with GFR ≥60 (normal) at baseline. Only patients with baseline GFR <45 experienced significant improvement in GFR after 2 years of follow-up (p = 0.012). At 1 month, a higher GFR category was significantly associated with a 31% reduction in mortality (hazard ratio [HR] 0.69, CI 0.49 to 0.98, p = 0.036), but not re-admission. Patients with baseline low and intermediate GFR who had no improvement in renal function category at 1 month experienced significantly greater risk of mortality (HR 1.95, CI 1.10 to 3.43, p = 0.022) and re-admission (HR 1.75, CI 1.07 to 2.84, p = 0.025), relative to patients whose GFR was normal at baseline and 1 month. In conclusion, renal function after LVAD implantation improves in patients with GFR <45. Change in renal function from baseline to 1 month after implantation is a powerful marker of long-term outcomes. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Long-term outcomes after severe shock.

    PubMed

    Pratt, Cristina M; Hirshberg, Eliotte L; Jones, Jason P; Kuttler, Kathryn G; Lanspa, Michael J; Wilson, Emily L; Hopkins, Ramona O; Brown, Samuel M

    2015-02-01

    Severe shock is a life-threatening condition with very high short-term mortality. Whether the long-term outcomes among survivors of severe shock are similar to long-term outcomes of other critical illness survivors is unknown. We therefore sought to assess long-term survival and functional outcomes among 90-day survivors of severe shock and determine whether clinical predictors were associated with outcomes. Seventy-six patients who were alive 90 days after severe shock (received ≥1 μg/kg per minute of norepinephrine equivalent) were eligible for the study. We measured 3-year survival and long-term functional outcomes using the Medical Outcomes Study 36-Item Short-Form Health Survey, the EuroQOL 5-D-3L, the Hospital Anxiety and Depression Scale, the Impact of Event Scale-Revised, and an employment instrument. We also assessed the relationship between in-hospital predictors and long-term outcomes. The mean long-term survival was 5.1 years; 82% (62 of 76) of patients survived, of whom 49 were eligible for follow-up. Patients who died were older than patients who survived. Thirty-six patients completed a telephone interview a mean of 5 years after hospital admission. The patients' Physical Functioning scores were below U.S. population norms (P < 0.001), whereas mental health scores were similar to population norms. Nineteen percent of the patients had symptoms of depression, 39% had symptoms of anxiety, and 8% had symptoms of posttraumatic stress disorder. Thirty-six percent were disabled, and 17% were working full-time. Early survivors of severe shock had a high 3-year survival rate. Patients' long-term physical and psychological outcomes were similar to those reported for cohorts of less severely ill intensive care unit survivors. Anxiety and depression were relatively common, but only a few patients had symptoms of posttraumatic stress disorder. This study supports the observation that acute illness severity does not determine long-term outcomes. Even extremely

  1. Biosynthetic hydrogels--studies on chemical and physical characteristics on long-term cellular response for tissue engineering.

    PubMed

    Thankam, Finosh Gnanaprakasam; Muthu, Jayabalan

    2014-07-01

    Biosynthetic hydrogels can meet the drawbacks caused by natural and synthetic ones for biomedical applications. In the current article we present a novel biosynthetic alginate-poly(propylene fumarate) copolymer based chemically crosslinked hydrogel scaffolds for cardiac tissue engineering applications. Partially crosslinked PA hydrogel and fully cross linked PA-A hydrogel scaffolds were prepared. The influence of chemical and physical (morphology and architecture of hydrogel) characteristics on the long term cellular response was studied. Both these hydrogels were cytocompatible and showed no genotoxicity upon contact with fibroblast cells. Both PA and PA-A were able to resist deleterious effects of reactive oxygen species and sustain the viability of L929 cells. The hydrogel incubated oxidative stress induced cells were capable of maintaining the intra cellular reduced glutathione (GSH) expression to the normal level confirmed their protective effect. Relatively the PA hydrogel was found to be unstable in the cell culture medium. The PA-A hydrogel was able to withstand appreciable cyclic stretching. The cyclic stretching introduced complex macro and microarchitectural features with interconnected pores and more structured bound water which would provide long-term viability of around 250% after the 24th day of culture. All these qualities make PA-A hydrogel form a potent candidate for cardiac tissue engineering. © 2013 Wiley Periodicals, Inc.

  2. Deleterious mutations and selection for sex in finite diploid populations.

    PubMed

    Roze, Denis; Michod, Richard E

    2010-04-01

    In diploid populations, indirect benefits of sex may stem from segregation and recombination. Although it has been recognized that finite population size is an important component of selection for recombination, its effects on selection for segregation have been somewhat less studied. In this article, we develop analytical two- and three-locus models to study the effect of recurrent deleterious mutations on a modifier gene increasing sex, in a finite diploid population. The model also incorporates effects of mitotic recombination, causing loss of heterozygosity (LOH). Predictions are tested using multilocus simulations representing deleterious mutations occurring at a large number of loci. The model and simulations show that excess of heterozygosity generated by finite population size is an important component of selection for sex, favoring segregation when deleterious alleles are nearly additive to dominant. Furthermore, sex tends to break correlations in homozygosity among selected loci, which disfavors sex when deleterious alleles are either recessive or dominant. As a result, we find that it is difficult to maintain costly sex when deleterious alleles are recessive. LOH tends to favor sex when deleterious mutations are recessive, but the effect is relatively weak for rates of LOH corresponding to current estimates (of the order 10(-4)-10(-5)).

  3. Working memory, short-term memory and reading proficiency in school-age children with cochlear implants.

    PubMed

    Bharadwaj, Sneha V; Maricle, Denise; Green, Laura; Allman, Tamby

    2015-10-01

    The objective of the study was to examine short-term memory and working memory through both visual and auditory tasks in school-age children with cochlear implants. The relationship between the performance on these cognitive skills and reading as well as language outcomes were examined in these children. Ten children between the ages of 7 and 11 years with early-onset bilateral severe-profound hearing loss participated in the study. Auditory and visual short-term memory, auditory and visual working memory subtests and verbal knowledge measures were assessed using the Woodcock Johnson III Tests of Cognitive Abilities, the Wechsler Intelligence Scale for Children-IV Integrated and the Kaufman Assessment Battery for Children II. Reading outcomes were assessed using the Woodcock Reading Mastery Test III. Performance on visual short-term memory and visual working memory measures in children with cochlear implants was within the average range when compared to the normative mean. However, auditory short-term memory and auditory working memory measures were below average when compared to the normative mean. Performance was also below average on all verbal knowledge measures. Regarding reading outcomes, children with cochlear implants scored below average for listening and passage comprehension tasks and these measures were positively correlated to visual short-term memory, visual working memory and auditory short-term memory. Performance on auditory working memory subtests was not related to reading or language outcomes. The children with cochlear implants in this study demonstrated better performance in visual (spatial) working memory and short-term memory skills than in auditory working memory and auditory short-term memory skills. Significant positive relationships were found between visual working memory and reading outcomes. The results of the study provide support for the idea that WM capacity is modality specific in children with hearing loss. Based on these

  4. Short-term Action Intentions Overrule Long-Term Semantic Knowledge

    ERIC Educational Resources Information Center

    van Elk, M.; van Schie, H.T.; Bekkering, H.

    2009-01-01

    In the present study, we investigated whether the preparation of an unusual action with an object (e.g. bringing a cup towards the eye) could selectively overrule long-term semantic representations. In the first experiment it was found that unusual action intentions activated short-term semantic goal representations, rather than long-term…

  5. Microsphere-based gradient implants for osteochondral regeneration: a long-term study in sheep

    PubMed Central

    Mohan, Neethu; Gupta, Vineet; Sridharan, Banu Priya; Mellott, Adam J; Easley, Jeremiah T; Palmer, Ross H; Galbraith, Richard A; Key, Vincent H; Berkland, Cory J; Detamore, Michael S

    2015-01-01

    Background: The microfracture technique for cartilage repair has limited ability to regenerate hyaline cartilage. Aim: The current study made a direct comparison between microfracture and an osteochondral approach with microsphere-based gradient plugs. Materials & methods: The PLGA-based scaffolds had opposing gradients of chondroitin sulfate and β-tricalcium phosphate. A 1-year repair study in sheep was conducted. Results: The repair tissues in the microfracture were mostly fibrous and had scattered fissures with degenerative changes. Cartilage regenerated with the gradient plugs had equal or superior mechanical properties; had lacunated cells and stable matrix as in hyaline cartilage. Conclusion: This first report of gradient scaffolds in a long-term, large animal, osteochondral defect demonstrated potential for equal or better cartilage repair than microfracture. PMID:26418471

  6. A Retrospective Multicentre Cohort Review of Patient Characteristics and Surgical Aspects versus the Long-Term Outcomes for Recipients of a Fully Implantable Active Middle Ear Implant

    PubMed Central

    Lefebvre, Philippe P.; Gisbert, Javier; Cuda, Domenico; Tringali, Stéphane; Deveze, Arnaud

    2017-01-01

    Objective To summarise treatment outcomes compared to surgical and patient variables for a multicentre recipient cohort using a fully implantable active middle ear implant for hearing impairment. To describe the authors' preferred surgical technique to determine microphone placement. Study Design Multicentre retrospective, observational survey. Setting Five tertiary referral centres. Patients Carina recipients (66 ears, 62 subjects) using the current Cochlear® Carina® System or the legacy device, the Otologics® Fully Implantable Middle Ear, with a T2 transducer. Methods Patient file review and routine clinical review. Patient outcomes assessed were satisfaction, daily use and feedback reports at the first fitting and ≥12 months after implantation. Descriptive and statistical analysis of correlations of variables and their influence on outcomes was performed. Independently reported preferred methods for microphone placement are collectively summarised. Results The average implant experience was 3.5 years. Satisfaction increased significantly over time (p < 0.05). No correlation with covariates examined was observed. Feedback significantly decreased over time, showing a significant correlation with microphone location, primary motivation, gender, age at implantation, and contralateral hearing aid use (p < 0.05). Patient satisfaction was inversely correlated with reports of system feedback (p < 0.05). The implantable microphone was most commonly on the posterior inferior mastoid line, in 42/66 (65%) cases, correlating with less likelihood for feedback and consistent with author surgical preference. Conclusion Carina recipients in this study present as satisfied consistent daily users with very few reports of persistent feedback. As microphone location is an influencing factor, a careful surgical consideration of microphone placement is required. The authors prefer a posterior inferior mastoid line position whenever possible. PMID:28052264

  7. Endovascular Stent Treatment for Symptomatic Benign Iliofemoral Venous Occlusive Disease: Long-Term Results 1987-2009

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gutzeit, A., E-mail: andreas.gutzeit@ksw.ch; Zollikofer, Ch. L., E-mail: Christoph.Zollikofer@ksb.ch; Dettling-Pizzolato, M., E-mail: Mira.Dettling@ksw.ch

    Venous stenting has been shown to effectively treat iliofemoral venous obstruction with good short- and mid-term results. The aim of this study was to investigate long-term clinical outcome and stent patency. Twenty patients were treated with venous stenting for benign disease at our institution between 1987 and 2005. Fifteen of 20 patients (15 female, mean age at time of stent implantation 38 years [range 18-66]) returned for a clinical visit, a plain X-ray of the stent, and a Duplex ultrasound. Four patients were lost to follow-up, and one patient died 277 months after stent placement although a good clinical resultmore » was documented 267 months after stent placement. Mean follow-up after stent placement was 167.8 months (13.9 years) (range 71 (6 years) to 267 months [22 years]). No patient needed an additional venous intervention after stent implantation. No significant difference between the circumference of the thigh on the stented side (mean 55.1 cm [range 47.0-70.0]) compared with the contralateral thigh (mean 54.9 cm [range 47.0-70.0]) (p = 0.684) was seen. There was a nonsignificant trend toward higher flow velocities within the stent (mean 30.8 cm/s [range 10.0-48.0]) and the corresponding vein segment on the contralateral side (mean 25.2 cm/s [range 12.0-47.0]) (p = 0.065). Stent integrity was confirmed in 14 of 15 cases. Only one stent showed a fracture, as documented on x-ray, without any impairment of flow. Venous stenting using Wallstents showed excellent long-term clinical outcome and primary patency rate.« less

  8. Chemical, corrosion and topographical analysis of stainless steel implants after different implantation periods.

    PubMed

    Chrzanowski, Wojciech; Armitage, David Andrew; Knowles, Jonathan Campbell; Szade, Jacek; Korlacki, Wojciech; Marciniak, Jan

    2008-07-01

    The aim of this work is to examine the corrosion properties, chemical composition, and material-implant interaction after different periods of implantation of plates used to correct funnel chest. The implants are made of 316L stainless steel. Examinations are carried out on three implants: new (nonimplanted) and two implanted for 29 and 35 months. The corrosion study reveals that in the potential range that could occur in the physiological condition the new bar has the lowest current density and the highest corrosion potential. This indicates that the new plate has the highest corrosion resistance and the corrosion resistance could be reduced during implantation by the instruments used during the operation. XPS analysis reveals changes in the surface chemistry. The longer the implantation time the more carbon and oxygen are observed and only trace of elements such as Cr, Mo are detected indicating that surface is covered by an organic layer. On some parts of the implants whitish tissue is observed: the thickness of which increased with the time of implantation. This tissue was identified as an organic layer; mainly attached to the surface on the areas close to where the implant was bent to attain anatomical fit and thus where the implant has higher surface roughness. The study indicates that the chest plates are impaired by the implantation procedure and contact with biological environment. The organic layer on the surface shows that the implant did not stay passive but some reactions at the tissue-implant interface occurred. These reactions should be seen as positive, as it indicates that the implants were accepted by the tissues. Nevertheless, if the implants react, they may continue to release chromium, nickel, and other harmful ions long term as indicated by lower corrosion resistance of the implants following implantation.

  9. Bone quality and the immediate loading of implants-critical aspects based on literature, research, and clinical experience.

    PubMed

    Romanos, Georgios E

    2009-06-01

    Immediate loading of oral implants has been extensively described in the international literature and the requirements for long-term success are evaluated. The author presents here the critical aspects of the criteria for success as well as describes the characteristics of an implant macro- and microdesign for immediate loading to control the periimplant crestal bone loss and secure the long-term stability. Information from the literature and the clinical experience will be presented.

  10. Occlusal considerations in implant therapy: clinical guidelines with biomechanical rationale.

    PubMed

    Kim, Yongsik; Oh, Tae-Ju; Misch, Carl E; Wang, Hom-Lay

    2005-02-01

    Due to lack of the periodontal ligament, osseointegrated implants, unlike natural teeth, react biomechanically in a different fashion to occlusal force. It is therefore believed that dental implants may be more prone to occlusal overloading, which is often regarded as one of the potential causes for peri-implant bone loss and failure of the implant/implant prosthesis. Overloading factors that may negatively influence on implant longevity include large cantilevers, parafunctions, improper occlusal designs, and premature contacts. Hence, it is important to control implant occlusion within physiologic limit and thus provide optimal implant load to ensure a long-term implant success. The purposes of this paper are to discuss the importance of implant occlusion for implant longevity and to provide clinical guidelines of optimal implant occlusion and possible solutions managing complications related to implant occlusion. It must be emphasized that currently there is no evidence-based, implant-specific concept of occlusion. Future studies in this area are needed to clarify the relationship between occlusion and implant success.

  11. Follow-up of the original cohort with the Ahmed glaucoma valve implant.

    PubMed

    Topouzis, F; Coleman, A L; Choplin, N; Bethlem, M M; Hill, R; Yu, F; Panek, W C; Wilson, M R

    1999-08-01

    To study the long-term results of the Ahmed glaucoma valve implant in patients with complicated glaucoma in whom short-term results have been reported. In this multicenter study, we analyzed the long-term outcome of a cohort of 60 eyes from 60 patients in whom the Ahmed glaucoma valve was implanted. Failure was characterized by at least one of the following: intraocular pressure greater than 21 mm Hg at both of the last two visits less than 6 mm Hg at both of the last two visits, loss of light perception, additional glaucoma surgery, devastating complications, and removal or replacement of the Ahmed glaucoma valve implant. Devastating complications included chronic hypotony, retinal detachment, malignant glaucoma, endophthalmitis, and phthisis bulbi; we also report results that add corneal complications (corneal decompensation or edema, corneal graft failure) as defining a devastating complication. The mean follow-up time for the 60 eyes was 30.5 months (range, 2.1 to 63.5). When corneal complications were included in the definition of failure, 26 eyes (43%) were considered failures. Cumulative probabilities of success at 1, 2, 3, and 4 years were 76%, 68%, 54%, and 45%, respectively. When corneal complications were excluded from the definition of failure, 13 eyes (21.5%) were considered failures. Cumulative probabilities of success at 1, 2, 3, and 4 years were 87%, 82%, 76%, and 76%, respectively. Most of the failures after 12 months of postoperative follow-up were because of corneal complications. The long-term performance of the Ahmed glaucoma valve implant is comparable to other drainage devices. More than 12 months after the implantation of the Ahmed glaucoma valve implant, the most frequent adverse outcome was corneal decompensation or corneal graft failure. These corneal problems may be secondary to the type of eyes that have drainage devices or to the drainage device itself. Further investigation is needed to identify the reasons that corneal problems

  12. Compensation for PKMζ in long-term potentiation and spatial long-term memory in mutant mice.

    PubMed

    Tsokas, Panayiotis; Hsieh, Changchi; Yao, Yudong; Lesburguères, Edith; Wallace, Emma Jane Claire; Tcherepanov, Andrew; Jothianandan, Desingarao; Hartley, Benjamin Rush; Pan, Ling; Rivard, Bruno; Farese, Robert V; Sajan, Mini P; Bergold, Peter John; Hernández, Alejandro Iván; Cottrell, James E; Shouval, Harel Z; Fenton, André Antonio; Sacktor, Todd Charlton

    2016-05-17

    PKMζ is a persistently active PKC isoform proposed to maintain late-LTP and long-term memory. But late-LTP and memory are maintained without PKMζ in PKMζ-null mice. Two hypotheses can account for these findings. First, PKMζ is unimportant for LTP or memory. Second, PKMζ is essential for late-LTP and long-term memory in wild-type mice, and PKMζ-null mice recruit compensatory mechanisms. We find that whereas PKMζ persistently increases in LTP maintenance in wild-type mice, PKCι/λ, a gene-product closely related to PKMζ, persistently increases in LTP maintenance in PKMζ-null mice. Using a pharmacogenetic approach, we find PKMζ-antisense in hippocampus blocks late-LTP and spatial long-term memory in wild-type mice, but not in PKMζ-null mice without the target mRNA. Conversely, a PKCι/λ-antagonist disrupts late-LTP and spatial memory in PKMζ-null mice but not in wild-type mice. Thus, whereas PKMζ is essential for wild-type LTP and long-term memory, persistent PKCι/λ activation compensates for PKMζ loss in PKMζ-null mice.

  13. Coronary artery aneurysm after stent implantation: acute and long-term results after percutaneous treatment with a stent graft.

    PubMed

    Rubartelli, Paolo; Terzi, Giacomo; Borgo, Lorenzo; Giachero, Corinna

    2002-03-01

    A patient with unstable angina was treated with elective Palmaz-Schatz stent implantation on a focal stenosis of the left circumflex artery. One year later, a large (13 mm in diameter) coronary artery aneurysm was diagnosed at angiography in the stented site. Intravascular ultrasound examination confirmed the presence of a true aneurysm located at the proximal end of the stent. The aneurysm was successfully treated with a Jostent Graft (Jomed Implantate) consisting of two slotted tube stainless steel stents supporting a polytetrafluoroethylene tube. The stent graft was implanted under intravascular ultrasound guidance. The 18-month angiographic follow-up showed good patency of the stent graft and complete exclusion of the aneurysm.

  14. Durability of Anti-Infective Effect of Long-Term Silicone Sheath Catheters Impregnated with Antimicrobial Agents

    PubMed Central

    Tcholakian, Robert K.; Raad, Issam I.

    2001-01-01

    This study was performed to test the long-term antimicrobial efficacy of impregnated silicone catheters comprising an antimicrobial layer sandwiched between an external surface sheath and a luminal surface silicone sheath. The design of the catheter permits the introduction of various antimicrobials in addition to anticoagulants or antifibrins in the antimicrobial layer and allows their gradual release over a period of months after insertion. The in vitro data presented show that the catheter can provide antimicrobial activity for 90 days, after being replated for 15 7-day cycles of replating. When the catheters were immersed in human serum and incubated at 37°C, they demonstrated significant antimicrobial activity after more than 325 days of incubation. The significant long-term in vitro antimicrobial activity observed may imply effective in vivo activity for almost 1 year after insertion and could serve as a cost-effective alternative to surgically implantable silicone catheters. PMID:11408213

  15. Tubing erosion of an inflatable penile prosthesis long after implantation.

    PubMed

    Morales, Alvaro

    2014-06-01

    Erosion through skin of connecting tubing of an inflatable penile prosthesis (IPP) has not been previously reported. The aim of this study was to present a case of tubing erosion, review the pertinent literature, and discuss the possible causes and management options, including preservation of the device and its components. A 42-year-old male failing to respond to medical treatment for erectile dysfunction underwent insertion of an AMS 700 IPP in 1986. Six years later, a revision was necessary because of a leak in the right cylinder and 4 years after, the pump was replaced. Fourteen years after the original implant, he presented with a portion of the tube connecting the pump to the right cylinder eroding through the skin. There was no infection. The skin area involved was resected and the original pump and tubing were buried in a new scrotal pocket after thorough irrigation. The IPP remained in place, allowing vaginal penetration and without infection for another 11 years. Three years later, it was de-functionalized, converted into a fixed volume device. It eventually was replaced 25 years after originally implanted with a semirigid prosthesis because it did not provide sufficient rigidity and because of concerns about the presence of "screws" detected during pelvic imaging. Mechanical failures in the early IPP models, as illustrated in this case, were expected. However, the long survival of the device is remarkable. Erosion of the connecting tubing through the skin is unique and, under exceptional circumstances, may be managed conservatively without replacing components of the IPP. Clinicians unfamiliar with procedures involving inflatable devices need to be aware of "foreign bodies" visible in radiological examinations in men who have had revisions of an IPP. Morales A. Tubing erosion of an inflatable penile prosthesis long after implantation. Sex Med 2014;2:103-106.

  16. Implantable Myoelectric Sensors (IMESs) for Intramuscular Electromyogram Recording

    PubMed Central

    Weir, Richard F. ff.; Troyk, Phil R.; DeMichele, Glen A.; Kerns, Douglas A.; Schorsch, Jack F.; Maas, Huub

    2011-01-01

    We have developed a multichannel electrogmyography sensor system capable of receiving and processing signals from up to 32 implanted myoelectric sensors (IMES). The appeal of implanted sensors for myoelectric control is that electromyography (EMG) signals can be measured at their source providing relatively cross-talk-free signals that can be treated as independent control sites. An external telemetry controller receives telemetry sent over a transcutaneous magnetic link by the implanted electrodes. The same link provides power and commands to the implanted electrodes. Wireless telemetry of EMG signals from sensors implanted in the residual musculature eliminates the problems associated with percutaneous wires, such as infection, breakage, and marsupialization. Each implantable sensor consists of a custom-designed application-specified integrated circuit that is packaged into a bio-compatible RF BION capsule from the Alfred E. Mann Foundation. Implants are designed for permanent long-term implantation with no servicing requirements. We have a fully operational system. The system has been tested in animals. Implants have been chronically implanted in the legs of three cats and are still completely operational four months after implantation. PMID:19224729

  17. [Heart transplantation and long-term lvad support cost-effectiveness model].

    PubMed

    Szentmihályi, Ilona; Barabás, János Imre; Bali, Ágnes; Kapus, Gábor; Tamás, Csilla; Sax, Balázs; Németh, Endre; Pólos, Miklós; Daróczi, László; Kőszegi, Andrea; Cao, Chun; Benke, Kálmán; Kovács, Péter Barnabás; Fazekas, Levente; Szabolcs, Zoltán; Merkely, Béla; Hartyánszky, István

    2016-12-01

    Heart transplantation is a high priority project at Semmelweis University. In accordance with this, the funding of heart transplantation and mechanical circulatory support also constitutes an important issue. In this report, the authors discuss the creation of a framework with the purpose of comparing the cost-effectiveness of heart transplantation and artificial heart implantation. Our created framework includes the calculation of cost, using the direct allocation method, calculating the incremental cost-effectiveness ratio and creating a cost-effectiveness plane. Using our model, it is possible to compare the initial, perioperative and postoperative expenses of both the transplanted and the artificial heart groups. Our framework can possibly be used for the purposes of long term follow-up and with the inclusion of a sufficient number of patients, the creation of cost-effectiveness analyses and supporting strategic decision-making.

  18. The use of CO(2) laser in the treatment of peri-implantitis.

    PubMed

    Romanos, George; Ko, Hua-Hsin; Froum, Stuart; Tarnow, Dennis

    2009-06-01

    Different techniques have been used for the treatment of peri-implant defects. However, there are always questions about the issue of reosseointegration. The present paper explores the recent literature on the topic of peri-implantitis therapy, and presents a surgical protocol for implant surface decontamination using the CO(2) laser, grafting of the defect, and coverage with a membrane according to a clinical case. The results appear to be promising and may improve the long-term clinical outcomes of failing dental implants.

  19. Exploring views on current and future cochlear implant service delivery: the perspectives of users, parents and professionals at cochlear implant centres and in the community.

    PubMed

    Athalye, Sheetal; Archbold, Sue; Mulla, Imran; Lutman, Mark; Nikolopoulous, Thomas

    2015-09-01

    The objective of this survey was to explore the perceptions of implant users/carers and professionals across the UK about current and future cochlear implant service delivery and the challenges. Data were collected via an online questionnaire consisting of totally 22 questions. The questionnaire contained both open- and close-ended questions. Totally, seven hundred and forty-eight responses were received. In spite of the wide range of respondents, there was a broad consensus of opinion across groups. The majority of participants were satisfied with the service they currently receive, but wanted some changes. They reported their current experience of implant services to be mainly driven by decisions made by the implant team. For the future, they preferred the service to be mainly driven by decisions made jointly by the team and the user and/or parent/carer. The majority of participants wanted the cochlear implant services to be integrated into local audiology and other services such as education. Restrictions on number of candidates funded and political decisions and issues were seen as major challenges. Qualitative analysis of the open-ended responses supported the questionnaire responses. This research highlighted the benefits and limitations of the current cochlear implant service delivery as well as the potential implications for the long term. While respondents were generally happy with the current cochlear implant service provision, they expressed some concerns about the long-term sustainability and management, wanting integration into the local services, and more involvement of parents and users in decisions.

  20. Estimating long-term multivariate progression from short-term data.

    PubMed

    Donohue, Michael C; Jacqmin-Gadda, Hélène; Le Goff, Mélanie; Thomas, Ronald G; Raman, Rema; Gamst, Anthony C; Beckett, Laurel A; Jack, Clifford R; Weiner, Michael W; Dartigues, Jean-François; Aisen, Paul S

    2014-10-01

    Diseases that progress slowly are often studied by observing cohorts at different stages of disease for short periods of time. The Alzheimer's Disease Neuroimaging Initiative (ADNI) follows elders with various degrees of cognitive impairment, from normal to impaired. The study includes a rich panel of novel cognitive tests, biomarkers, and brain images collected every 6 months for as long as 6 years. The relative timing of the observations with respect to disease pathology is unknown. We propose a general semiparametric model and iterative estimation procedure to estimate simultaneously the pathological timing and long-term growth curves. The resulting estimates of long-term progression are fine-tuned using cognitive trajectories derived from the long-term "Personnes Agées Quid" study. We demonstrate with simulations that the method can recover long-term disease trends from short-term observations. The method also estimates temporal ordering of individuals with respect to disease pathology, providing subject-specific prognostic estimates of the time until onset of symptoms. When the method is applied to ADNI data, the estimated growth curves are in general agreement with prevailing theories of the Alzheimer's disease cascade. Other data sets with common outcome measures can be combined using the proposed algorithm. Software to fit the model and reproduce results with the statistical software R is available as the grace package. ADNI data can be downloaded from the Laboratory of NeuroImaging. Copyright © 2014 The Alzheimer's Association. Published by Elsevier Inc. All rights reserved.

  1. Modeling heat exchange characteristics of long term space operations: Role of skin wettedness and exercise

    NASA Technical Reports Server (NTRS)

    Gonzalez, Richard R.

    1994-01-01

    The problems of heat exchange during rest and exercise during long term space operations are covered in this report. Particular attention is given to the modeling and description of the consequences of requirement to exercise in a zero-g atmosphere during Space Shuttle flights, especially long term ones. In space environments, there exists no free convection therefore only forced convection occurring by movement, such as pedalling on a cycle ergometer, augments required heat dissipation necessary to regulate body temperature. The requirement to exercise at discrete periods of the day is good practice in order to resist the deleterious consequences of zero-gravity problems and improve distribution of body fluids. However, during exercise (ca. 180 to 250W), in zero-g environments, the mass of eccrine sweating rests as sheets on the skin surface and the sweat cannot evaporate readily. The use of exercise suits with fabrics that have hydrophobic or outwicking properties somewhat distributes the mass of sweat to a larger surface from which to evaporate. However, with no free convection, increased skin wettedness throughout the body surface induces increasing thermal discomfort, particularly during continuous exercise. This report presents several alternatives to aid in this problem: use of intermittent exercise, methods to quantify local skin wettedness, and introduction of a new effective temperature that integrates thermal stress and heat exchange avenues in a zero-g atmosphere.

  2. Evaluation of focused multipolar stimulation for cochlear implants in long-term deafened cats

    NASA Astrophysics Data System (ADS)

    George, Shefin S.; Wise, Andrew K.; Fallon, James B.; Shepherd, Robert K.

    2015-06-01

    Objective. Focused multipolar (FMP) stimulation has been shown to produce restricted neural activation using intracochlear stimulation in animals with a normal population of spiral ganglion neurons (SGNs). However, in a clinical setting, the widespread loss of SGNs and peripheral fibres following deafness is expected to influence the effectiveness of FMP. Approach. We compared the efficacy of FMP stimulation to both monopolar (MP) and tripolar (TP) stimulation in long-term deafened cat cochleae (n = 8). Unlike our previous study, these cochleae contained <10% of the normal SGN population adjacent to the electrode array. We also evaluated the effect of electrode position on stimulation modes by using either modiolar facing or lateral wall facing half-band electrodes. The spread of neural activity across the inferior colliculus, a major nucleus within the central auditory pathway, was used as a measure of spatial selectivity. Main results. In cochleae with significant SGN degeneration, we observed that FMP and TP stimulation resulted in greater spatial selectivity than MP stimulation (p < 0.001). However, thresholds were significantly higher for FMP and TP stimulation compared to MP stimulation (p < 0.001). No difference between FMP and TP stimulation was found in any measures. The high threshold levels for FMP stimulation was significantly reduced without compromising spatial selectivity by varying the degree of current focusing (referred as ‘partial-FMP’ stimulation). Spatial selectivity of all stimulation modes was unaffected by the electrode position. Finally, spatial selectivity in long-term deafened cochleae was significantly less than that of cochleae with normal SGN population (George S S et al 2014 J. Neural Eng. 11 065003). Significance. The present results indicate that the greater spatial selectivity of FMP and TP stimulation over MP stimulation is maintained in cochleae with significant neural degeneration and is not adversely affected by electrode

  3. Scientific Understanding from Long Term Observations: Insights from the Long Term Ecological Research (LTER) Program

    NASA Astrophysics Data System (ADS)

    Gosz, J.

    2001-12-01

    The network dedicated to Long Term Ecological Research (LTER) in the United States has grown to 24 sites since it was formed in 1980. Long-term research and monitoring are performed on parameters thatare basic to all ecosystems and are required to understand patterns, processes, and relationship to change. Collectively, the sites in the LTER Network provide opportunities to contrast marine, coastal, and continental regions, the full range of climatic gradients existing in North America, and aquatic and terrestrial habitats in a range of ecosystem types. The combination of common core areas and long-term research and monitoring in many habitats have allowed unprecedented abilities to understand and compare complex temporal and spatial dynamics associated with issues like climate change, effects of pollution, biodiversity and landuse. For example, McMurdo Dry Valley in the Antarctic has demonstrated an increase in glacier mass since 1993 which coincides with a period of cooler than normal summers and more than average snowfall. In contrast, the Bonanza Creek and Toolik Lake sites in Alaska have recorded a warming period unprecedented in the past 200 years. Nitrogen deposition effects have been identified through long-term watershed studies on biogeochemical cycles, especially at Coweeta Hydrological Lab, Harvard Forest, and the Hubbard Brook Experimental Forest. In aquatic systems, such as the Northern Temperate Lakes site, long-term data revealed time lags in effects of invaders and disturbance on lake communities. Biological recovery from an effect such as lake acidification was shown to lag behind chemical recovery. The long-term changes documented over 2 decades have been instrumental in influencing management practices in many of the LTER areas. In Puerto Rico, the Luquillo LTER demonstrated that dams obstruct migrations of fish and freshwater shrimp and water abstraction at low flows can completely obliterate downstream migration of juveniles and damage

  4. Long-Term Opioid Therapy Reconsidered

    PubMed Central

    Von Korff, Michael; Kolodny, Andrew; Deyo, Richard A.; Chou, Roger

    2012-01-01

    In the past 20 years, primary care physicians have greatly increased prescribing of long-term opioid therapy. However, the rise in opioid prescribing has outpaced the evidence regarding this practice. Increased opioid availability has been accompanied by an epidemic of opioid abuse and overdose. The rate of opioid addiction among patients receiving long-term opioid therapy remains unclear, but research suggests that opioid misuse is not rare. Recent studies report increased risks for serious adverse events, including fractures, cardiovascular events, and bowel obstruction, although further research on medical risks is needed. New data indicate that opioid-related risks may increase with dose. From a societal perspective, higher-dose regimens account for the majority of opioids dispensed, so cautious dosing may reduce both diversion potential and patient risks for adverse effects. Limiting long-term opioid therapy to patients for whom it provides decisive benefits could also reduce risks. Given the warning signs and knowledge gaps, greater caution and selectivity are needed in prescribing long-term opioid therapy. Until stronger evidence becomes available, clinicians should err on the side of caution when considering this treatment. PMID:21893626

  5. Clinical characterisation and long-term prognosis of women with Brugada syndrome.

    PubMed

    Sieira, Juan; Conte, Giulio; Ciconte, Giuseppe; de Asmundis, Carlo; Chierchia, Gian-Battista; Baltogiannis, Giannis; Di Giovanni, Giacomo; Saitoh, Yukio; Irfan, Ghazala; Casado-Arroyo, Ruben; Juliá, Justo; La Meir, Mark; Wellens, Francis; Wauters, Kristel; Pappaert, Gudrun; Brugada, Pedro

    2016-03-01

    Brugada syndrome (BS) in women is considered an infrequent condition with a more favourable prognosis than in men. Nevertheless, arrhythmic events and sudden cardiac death (SCD) also occur in this population. Long-term follow-up data of this group are sparse. The purpose of the present study was to investigate the clinical characteristics and long-term prognosis of women with BS. A consecutive cohort of 228 women presenting with spontaneous or drug-induced Brugada type I ECG at our institution were included and compared with 314 men with the same diagnosis. Mean age was 41.5±17.3 years. Clinical presentation was SCD in 6 (2.6%), syncope in 51 (22.4%) and the remaining 171 (75.0%) were asymptomatic. As compared with men, spontaneous type I ECG was less common (7.9% vs 23.2%, p<0.01) and less ventricular arrhythmias were induced during programmed electrical stimulation (5.5% vs 22.3%, p<0.01). An implantable cardioverter defibrillator (ICD) was implanted in 64 women (28.1%). During a mean follow-up of 73.2±56.2 months, seven patients developed arrhythmic events, constituting an event rate of 0.7% per year (as compared with 1.9% per year in men, p=0.02). Presentation as SCD or sinus node dysfunction (SND) was risk factor significantly associated with arrhythmic events (hazard risk (HR) 25.4 and 9.1). BS is common in women, representing 42% of patients in our database. Clinical presentation is less severe than men, with more asymptomatic status and less spontaneous type I ECG and prognosis is more favourable, with an event rate of 0.7% year. However, women with SCD or previous SND are at higher risk of arrhythmic events. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  6. Significant effects of atrioventricular node ablation and pacemaker implantation on left ventricular function and long-term survival in patients with atrial fibrillation and left ventricular dysfunction.

    PubMed

    Ozcan, Cevher; Jahangir, Arshad; Friedman, Paul A; Munger, Thomas M; Packer, Douglas L; Hodge, David O; Hayes, David L; Gersh, Bernard J; Hammill, Stephen C; Shen, Win-Kuang

    2003-07-01

    Control of ventricular rate by atrioventricular node ablation and pacemaker implantation in patients with drug-refractory atrial fibrillation (AF) is associated with improved left ventricular (LV) function. The objective of this study was to determine the effect of atrioventricular node ablation on long-term survival in patients with AF and LV dysfunction. Survival was determined by the Kaplan-Meier method for 56 study patients with LV ejection fraction (EF) < or =40% who underwent atrioventricular node ablation and pacemaker implantation and 56 age- and gender-matched control patients with AF and LVEF >40%, and age- and gender-matched control subjects from Minnesota. Groups were compared using the log-rank test. In study patients (age 69 +/- 10 years; 45 men), LVEF was 26% +/- 8% and 34% +/- 13% (p <0.001) before and after ablation, respectively. During follow-up (40 +/- 23 months), 23 patients died. Observed survival was worse than that of normal subjects (p <0.001) and control patients (p = 0.005). After ablation, LVEF nearly normalized (> or =45%) in 16 study patients (29%), in whom observed survival was comparable to that of normal subjects (p = 0.37). Coronary artery disease, hyperlipidemia, chronic renal failure, previous myocardial infarction, and coronary artery operation were independent predictors for mortality. Near normalization of LVEF occurred in 29% of study patients, suggesting that AF-induced EF reduction is reversible in many patients. Normal survival in patients with reversible LV dysfunction highlights potential survival benefits of rate control. Poor survival in patients with persistent LV dysfunction confirms the importance of optimal medical therapy.

  7. Long-term in vivo left ventricular assist device study with a titanium centrifugal pump.

    PubMed

    Ohtsuka, G; Nakata, K; Yoshikawa, M; Mueller, J; Takano, T; Yamane, S; Gronau, N; Glueck, J; Takami, Y; Sueoka, A; Letsou, G; Schima, H; Schmallegger, H; Wolner, E; Koyanagi, H; Fujisawa, A; Baldwin, J C; Nosé, Y

    1998-01-01

    A totally implantable centrifugal artificial heart has been developed. The plastic prototype, Gyro PI 601, passed 2 day hemodynamic tests as a functional total artificial heart, 2 week screening tests for antithrombogenicity, and 1 month system feasibility. Based on these results, a metallic prototype, Gyro PI 702, was subjected to in vivo left ventricular assist device (LVAD) studies. The pump system employed the Gyro PI 702, which has the same inner dimensions and the same characteristics as the Gyro PI 601, including an eccentric inlet port, a double pivot bearing system, and a magnet coupling system. The PI 702 is driven with the Vienna DC brushless motor actuator. For the in vivo LVAD study, the pump actuator package was implanted in the preperitoneal space in two calves, from the left ventricular apex to the descending aorta. Case 1 achieved greater than 9 month survival without any complications, at an average flow rate of 6.6 L/min with 10.2 W input power. Case 2 was killed early due to the excessive growth of the calf, which caused functional obstruction of the inlet port. There was no blood clot inside the pump. During these periods, neither case exhibited any physiologic abnormalities. The PI 702 pump gives excellent results as a long-term implantable LVAD.

  8. Long-term antibacterial characteristics and cytocompatibility of titania nanotubes loaded with Au nanoparticles without photocatalytic effects

    NASA Astrophysics Data System (ADS)

    Wang, Guomin; Feng, Hongqing; Jin, Weihong; Gao, Ang; Peng, Xiang; Li, Wan; Wu, Hao; Li, Zhou; Chu, Paul K.

    2017-08-01

    Au nanoparticles (NPs) can endow titania nanotubes (Au@TiO2-NT) with light-independent antibacterial properties which bode well for in vivo application because of the dark environment inside tissues. In this work, the long-term antibacterial bactericidal properties and cytocompatibility of Au@TiO2-NT without photocatalytic effects are studied in details. The materials exhibit antibacterial effects against Staphylococcus aureus according to antibacterial tests carried out for a total time of 21 days, which are normally long enough for early stage tissue healing after surgery. In addition, adhesion and proliferation of MC3T3-E1 osteoblasts on Au@TiO2-NT reveal cytocompatibility comparable to that of TiO2-NT. No reactive oxygen species (ROS) are detected from either the bacteria or MC3T3-E1 cells cultured on the Au@TiO2-NT surface. The absence of ROS, long-term antibacterial properties, and cytocompatibility make Au@TiO2-NT promising biomaterials in orthopedic devices and implants.

  9. Very long-term sequelae of craniopharyngioma.

    PubMed

    Wijnen, Mark; van den Heuvel-Eibrink, Marry M; Janssen, Joseph A M J L; Catsman-Berrevoets, Coriene E; Michiels, Erna M C; van Veelen-Vincent, Marie-Lise C; Dallenga, Alof H G; van den Berge, J Herbert; van Rij, Carolien M; van der Lely, Aart-Jan; Neggers, Sebastian J C M M

    2017-06-01

    Studies investigating long-term health conditions in patients with craniopharyngioma are limited by short follow-up durations and generally do not compare long-term health effects according to initial craniopharyngioma treatment approach. In addition, studies comparing long-term health conditions between patients with childhood- and adult-onset craniopharyngioma report conflicting results. The objective of this study was to analyse a full spectrum of long-term health effects in patients with craniopharyngioma according to initial treatment approach and age group at craniopharyngioma presentation. Cross-sectional study based on retrospective data. We studied a single-centre cohort of 128 patients with craniopharyngioma treated from 1980 onwards (63 patients with childhood-onset disease). Median follow-up since craniopharyngioma presentation was 13 years (interquartile range: 5-23 years). Initial craniopharyngioma treatment approaches included gross total resection ( n  = 25), subtotal resection without radiotherapy ( n  = 44), subtotal resection with radiotherapy ( n  = 25), cyst aspiration without radiotherapy ( n  = 8), and 90 Yttrium brachytherapy ( n  = 21). Pituitary hormone deficiencies (98%), visual disturbances (75%) and obesity (56%) were the most common long-term health conditions observed. Different initial craniopharyngioma treatment approaches resulted in similar long-term health effects. Patients with childhood-onset craniopharyngioma experienced significantly more growth hormone deficiency, diabetes insipidus, panhypopituitarism, morbid obesity, epilepsy and psychiatric conditions compared with patients with adult-onset disease. Recurrence-/progression-free survival was significantly lower after initial craniopharyngioma treatment with cyst aspiration compared with other therapeutic approaches. Survival was similar between patients with childhood- and adult-onset craniopharyngioma. Long-term health conditions were comparable after

  10. Clinically apparent long-term electric disturbances in the acute and very long-term of patent foramen ovale device-based closure.

    PubMed

    Rigatelli, Gianluca; Zuin, Marco; Pedon, Luigi; Zecchel, Roberto; Dell'Avvocata, Fabio; Carrozza, Antonio; Zennaro, Marco; Pastore, Gianni; Zanon, Francesco

    2017-03-01

    Incidence of electrical disturbances in patients submitted to transcatheter patent foramen ovale (PFO) closure has not been fully clarified in a large population. The aim of the study is to assess the incidence of atrial fibrillation, supraventricular tachi-arrhythmias, and atrio-ventricular block in the acute and very long-term follow-up. We reviewed the medical and instrumental data of 1000 consecutive patients (mean age 47.3±17.1years) prospectively enrolled in two centers over a 13-year period (February 1999 to February 2012) for right-to-left (R-to-L) shunt ICE-aided catheter-based closure using different devices. Successful transcatheter PFO closure was achieved in 99.8% of the patients. Implanted devices were: Amplatzer PFO Occluder in 463 patients (46.3%), Amplatzer ASD Cribriform Occluder in 420 patients (42.0%), Premere Occlusion System in 95 patients (9.5%), and Biostar Occluder in 22 patients (2.2%). Postprocedural electrical complications occurred in 5.9% of patients. The only independent predictors of electrophysiological complications were female gender (OR 2.3, 0.5-5.1 [95% CI], p<0.001) and device disk >30mm (OR 5.0, 1.2-7.2 [95% CI], p<0.001). On a mean follow-up of 12 .3±0.6years (minimum 4- maximum 17years), electrical complications occurred in 1.4% of patients including one only case of complete AVB and 5 cases of permanent AF. The only independent predictors were female gender (OR 2.3, 0.5-5.1 [95% CI], p<0.001) and device disk >30mm (OR 5.0, 1.2-7.2 [95% CI], p<0.001). Device-based closure of PFO using different devices, appeared very safe from an electrophysiological point of view with low incidence of electrical disturbances even in the very long-term follow-up. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Dental implants modified with drug releasing titania nanotubes: therapeutic potential and developmental challenges.

    PubMed

    Gulati, Karan; Ivanovski, Sašo

    2017-08-01

    The transmucosal nature of dental implants presents a unique therapeutic challenge, requiring not only rapid establishment and subsequent maintenance of osseointegration, but also the formation of resilient soft tissue integration. Key challenges in achieving long-term success are sub-optimal bone integration in compromised bone conditions and impaired trans-mucosal tissue integration in the presence of a persistent oral microbial biofilm. These challenges can be targeted by employing a drug-releasing implant modification such as TiO 2 nanotubes (TNTs), engineered on titanium surfaces via electrochemical anodization. Areas covered: This review focuses on applications of TNT-based dental implants towards achieving optimal therapeutic efficacy. Firstly, the functions of TNT implants will be explored in terms of their influence on osseointegration, soft tissue integration and immunomodulation. Secondly, the developmental challenges associated with such implants are reviewed including sterilization, stability and toxicity. Expert opinion: The potential of TNTs is yet to be fully explored in the context of the complex oral environment, including appropriate modulation of alveolar bone healing, immune-inflammatory processes, and soft tissue responses. Besides long-term in vivo assessment under masticatory loading conditions, investigating drug-release profiles in vivo and addressing various technical challenges are required to bridge the gap between research and clinical dentistry.

  12. Long-term stimulation by active epiretinal implants in normal and RCD1 dogs

    NASA Astrophysics Data System (ADS)

    Güven, Dilek; Weiland, James D.; Fujii, Gildo; Mech, Brian V.; Mahadevappa, Manjunatha; Greenberg, Robert; Roizenblatt, Roberto; Qiu, Guanting; La Bree, Laurie; Wang, Xiaopeng; Hinton, David; Humayun, Mark S.

    2005-03-01

    An epiretinal prosthesis, consisting of an extraocular microelectronic stimulator and an intraocular electrode array, was implanted in one eye of three blind and three sighted dogs. Three dogs (2 blind, 1 normal) were stimulated for 120 days, and two dogs (both normal) for 60 and 103 days respectively for 8-10 h/day at levels of 0.1 mC cm-2 and 0.05 mC cm-2, with each stimulus level presented to half of the array. One blind dog was kept as an inactive implant control. During the study period, electroretinograms (ERG) and fundus photographs were recorded. At the end of the study period, the dogs were sacrificed and histological and morphometric evaluation was made of the retina. No inflammatory reaction, neovascularization or hemorrhage was observed during the follow-up examinations. ERGs were unchanged. Stimulus levels used were of sufficient amplitude to elicit cortical evoked potentials. Histological evaluation showed no inflammatory infiltrates or changes in retina morphometry related to electrical stimulation when compared to the unstimulated control eye. Morphometric analysis revealed no consistent differences relating to electrical stimulation. In summary, chronic electrical stimulation of the dog retina at up to 0.1 mC cm-2 with an epiretinal prosthesis does not appear to adversely affect the retina. This study is supported by The Fletcher Jones Foundation, National Eye Institute Grants 1R24EY12893 and EY03040, the Whitaker Foundation and Second Sight Medical Products, Inc.

  13. Long-term care in international perspective.

    PubMed

    Doty, P

    1988-12-01

    The findings of a study of long-term care policies in 18 countries are reported in this article. Initial data were collected by a questionnaire survey under the auspices of the International Social Security Association. These data were supplemented by published documents and government statistics obtained while researching long-term care for the International Social Security Association and, subsequently, for the Organization for Economic Cooperation and Development. The principal focus is a cross-national comparison of institutionalization rates for the elderly. Differences in use rates for medically oriented facilities are less than those for nonmedical residential long-term care facilities. Only a small amount of variation is related to demographic differences, such as older or more female elderly populations in those countries with higher institutionalization rates. Included also is a description of the modes of financing long-term care.

  14. A neural interface provides long-term stable natural touch perception.

    PubMed

    Tan, Daniel W; Schiefer, Matthew A; Keith, Michael W; Anderson, James Robert; Tyler, Joyce; Tyler, Dustin J

    2014-10-08

    Touch perception on the fingers and hand is essential for fine motor control, contributes to our sense of self, allows for effective communication, and aids in our fundamental perception of the world. Despite increasingly sophisticated mechatronics, prosthetic devices still do not directly convey sensation back to their wearers. We show that implanted peripheral nerve interfaces in two human subjects with upper limb amputation provided stable, natural touch sensation in their hands for more than 1 year. Electrical stimulation using implanted peripheral nerve cuff electrodes that did not penetrate the nerve produced touch perceptions at many locations on the phantom hand with repeatable, stable responses in the two subjects for 16 and 24 months. Patterned stimulation intensity produced a sensation that the subjects described as natural and without "tingling," or paresthesia. Different patterns produced different types of sensory perception at the same location on the phantom hand. The two subjects reported tactile perceptions they described as natural tapping, constant pressure, light moving touch, and vibration. Changing average stimulation intensity controlled the size of the percept area; changing stimulation frequency controlled sensation strength. Artificial touch sensation improved the subjects' ability to control grasping strength of the prosthesis and enabled them to better manipulate delicate objects. Thus, electrical stimulation through peripheral nerve electrodes produced long-term sensory restoration after limb loss. Copyright © 2014, American Association for the Advancement of Science.

  15. A neural interface provides long-term stable natural touch perception

    PubMed Central

    Tan, Daniel W.; Schiefer, Matthew A.; Keith, Michael W.; Anderson, James Robert; Tyler, Joyce; Tyler, Dustin J.

    2017-01-01

    Touch perception on the fingers and hand is essential for fine motor control, contributes to our sense of self, allows for effective communication, and aids in our fundamental perception of the world. Despite increasingly sophisticated mechatronics, prosthetic devices still do not directly convey sensation back to their wearers. We show that implanted peripheral nerve interfaces in two human subjects with upper limb amputation provided stable, natural touch sensation in their hands for more than 1 year. Electrical stimulation using implanted peripheral nerve cuff electrodes that did not penetrate the nerve produced touch perceptions at many locations on the phantom hand with repeatable, stable responses in the two subjects for 16 and 24 months. Patterned stimulation intensity produced a sensation that the subjects described as natural and without “tingling,” or paresthesia. Different patterns produced different types of sensory perception at the same location on the phantom hand. The two subjects reported tactile perceptions they described as natural tapping, constant pressure, light moving touch, and vibration. Changing average stimulation intensity controlled the size of the percept area; changing stimulation frequency controlled sensation strength. Artificial touch sensation improved the subjects’ ability to control grasping strength of the prosthesis and enabled them to better manipulate delicate objects. Thus, electrical stimulation through peripheral nerve electrodes produced long-term sensory restoration after limb loss. PMID:25298320

  16. Long-term stability of intracortical recordings using perforated and arrayed Parylene sheath electrodes

    NASA Astrophysics Data System (ADS)

    Hara, Seth A.; Kim, Brian J.; Kuo, Jonathan T. W.; Lee, Curtis D.; Meng, Ellis; Pikov, Victor

    2016-12-01

    . This study provided support for the importance of creating a supportive biological environment around the probes to promote the long-term electrophysiological performance of flexible probes in the cerebral cortex. In particular, we demonstrated beneficial effects of the Matrigel coating and the long-term expression of Caveolin-1. Furthermore, we provided support to an idea of using an artificial acellular tissue compartment as a way to counteract the walling-off effect of the astrocytic scar formation around the probes as a means of establishing a more intimate and stable neural interface.

  17. Compensation for PKMζ in long-term potentiation and spatial long-term memory in mutant mice

    PubMed Central

    Tsokas, Panayiotis; Hsieh, Changchi; Yao, Yudong; Lesburguères, Edith; Wallace, Emma Jane Claire; Tcherepanov, Andrew; Jothianandan, Desingarao; Hartley, Benjamin Rush; Pan, Ling; Rivard, Bruno; Farese, Robert V; Sajan, Mini P; Bergold, Peter John; Hernández, Alejandro Iván; Cottrell, James E; Shouval, Harel Z; Fenton, André Antonio; Sacktor, Todd Charlton

    2016-01-01

    PKMζ is a persistently active PKC isoform proposed to maintain late-LTP and long-term memory. But late-LTP and memory are maintained without PKMζ in PKMζ-null mice. Two hypotheses can account for these findings. First, PKMζ is unimportant for LTP or memory. Second, PKMζ is essential for late-LTP and long-term memory in wild-type mice, and PKMζ-null mice recruit compensatory mechanisms. We find that whereas PKMζ persistently increases in LTP maintenance in wild-type mice, PKCι/λ, a gene-product closely related to PKMζ, persistently increases in LTP maintenance in PKMζ-null mice. Using a pharmacogenetic approach, we find PKMζ-antisense in hippocampus blocks late-LTP and spatial long-term memory in wild-type mice, but not in PKMζ-null mice without the target mRNA. Conversely, a PKCι/λ-antagonist disrupts late-LTP and spatial memory in PKMζ-null mice but not in wild-type mice. Thus, whereas PKMζ is essential for wild-type LTP and long-term memory, persistent PKCι/λ activation compensates for PKMζ loss in PKMζ-null mice. DOI: http://dx.doi.org/10.7554/eLife.14846.001 PMID:27187150

  18. Competitive short-term and long-term memory processes in spatial habituation.

    PubMed

    Sanderson, David J; Bannerman, David M

    2011-04-01

    Exposure to a spatial location leads to habituation of exploration such that, in a novelty preference test, rodents subsequently prefer exploring a novel location to the familiar location. According to Wagner's (1981) theory of memory, short-term and long-term habituation are caused by separate and sometimes opponent processes. In the present study, this dual-process account of memory was tested. Mice received a series of exposure training trials to a location before receiving a novelty preference test. The novelty preference was greater when tested after a short, rather than a long, interval. In contrast, the novelty preference was weaker when exposure training trials were separated by a short, rather than a long interval. Furthermore, it was found that long-term habituation was determined by the independent effects of the amount of exposure training and the number of exposure training trials when factors such as the intertrial interval and the cumulative intertrial interval were controlled. A final experiment demonstrated that a long-term reduction of exploration could be caused by a negative priming effect due to associations formed during exploration. These results provide evidence against a single-process account of habituation and suggest that spatial habituation is determined by both short-term, recency-based memory and long-term, incrementally strengthened memory.

  19. Deleterious Mutations, Apparent Stabilizing Selection and the Maintenance of Quantitative Variation

    PubMed Central

    Kondrashov, A. S.; Turelli, M.

    1992-01-01

    Apparent stabilizing selection on a quantitative trait that is not causally connected to fitness can result from the pleiotropic effects of unconditionally deleterious mutations, because as N. Barton noted, ``... individuals with extreme values of the trait will tend to carry more deleterious alleles ....'' We use a simple model to investigate the dependence of this apparent selection on the genomic deleterious mutation rate, U; the equilibrium distribution of K, the number of deleterious mutations per genome; and the parameters describing directional selection against deleterious mutations. Unlike previous analyses, we allow for epistatic selection against deleterious alleles. For various selection functions and realistic parameter values, the distribution of K, the distribution of breeding values for a pleiotropically affected trait, and the apparent stabilizing selection function are all nearly Gaussian. The additive genetic variance for the quantitative trait is kQa(2), where k is the average number of deleterious mutations per genome, Q is the proportion of deleterious mutations that affect the trait, and a(2) is the variance of pleiotropic effects for individual mutations that do affect the trait. In contrast, when the trait is measured in units of its additive standard deviation, the apparent fitness function is essentially independent of Q and a(2); and β, the intensity of selection, measured as the ratio of additive genetic variance to the ``variance'' of the fitness curve, is very close to s = U/k, the selection coefficient against individual deleterious mutations at equilibrium. Therefore, this model predicts appreciable apparent stabilizing selection if s exceeds about 0.03, which is consistent with various data. However, the model also predicts that β must equal V(m)/V(G), the ratio of new additive variance for the trait introduced each generation by mutation to the standing additive variance. Most, although not all, estimates of this ratio imply

  20. Long-term outcome after percutaneous closure of persistent left superior caval vein draining into the left atrium: a contrast-enhanced CT study.

    PubMed

    Marini, Davide; Castagno, Matteo; Millesimo, Michele; Ferroni, Francesca; Ferraro, Gaetana; Pace Napoleone, Carlo; Agnoletti, Gabriella

    2017-10-01

    Data regarding long-term outcome after percutaneous closure of left superior caval vein draining into the left atrium are lacking. The aim of the present study was to report the long-term follow-up by using contrast-enhanced CT. In all, three patients underwent percutaneous closure of left superior caval vein draining into the left atrium between 2005 and 2015. All of them were evaluated clinically and underwent contrast-enhanced CT. In one patient, the Amplatzer® Septal Occluder was used. In two patients, the Amplatzer® Vascular Plug type-1 was preferred: the device size/LSVC diameter ratio was 1.7 in the child and 1.2 in the adult. There were no early-onset or long-term onset complications. CT was performed 1, 2, and 10 years after the procedure, respectively. Complete occlusion of the vessel was documented in all. After 10 years since the procedure, CT revealed a persistent trivial residual shunt through the accessory hemiazygos vein in one patient, in whom the device was implanted above its drainage into the left superior caval vein. When an Amplatzer® Vascular Plug type-1 is oversized compared with the venous vessel diameter, it immediately assumes a dog-bone shape that disappears early to regain its shape memory and nominal size. Percutaneous occlusion of left superior caval vein draining into the left atrium has excellent early and long-term outcomes. The optimal implantation of the device is below the drainage of the accessory hemiazygos vein, when present. The device might be oversized compared with the left superior caval vein diameter according to the age of the patient.

  1. Clinical and Radiologic Outcomes of Submerged and Nonsubmerged Bone-Level Implants with Internal Hexagonal Connections in Immediate Implantation: A 5-Year Retrospective Study.

    PubMed

    Wu, Shiyu; Wu, Xiayi; Shrestha, Rachana; Lin, Jinying; Feng, Zhicai; Liu, Yudong; Shi, Yunlin; Huang, Baoxin; Li, Zhipeng; Liu, Quan; Zhang, Xiaocong; Hu, Mingxuan; Chen, Zhuofan

    2018-02-01

    To evaluate the 5-year clinical and radiologic outcome of immediate implantation using submerged and nonsubmerged techniques with bone-level implants and internal hexagonal connections and the effects of potential influencing factors. A total of 114 bone-level implants (XiVE S plus) with internal hexagonal connections inserted into 72 patients were included. Patients were followed up for 5 years. A t-test was used to statistically evaluate the marginal bone loss between the submerged and nonsubmerged groups. The cumulative survival rate (CSR) was calculated according to the life table method and illustrated with Kaplan-Meier survival curves. Comparisons of the CSR between healing protocols, guided bone regeneration, implants with different sites, lengths, and diameters were performed using log-rank tests. The 5-year cumulative implant survival rates with submerged and nonsubmerged healing were 94% and 96%, respectively. No statistically significant differences in terms of marginal bone loss, healing protocol, application of guided bone regeneration, implant site, or length were observed. High CSRs and good marginal bone levels were achieved 5 years after immediate implantation of bone-level implants with internal hexagonal connections using both the submerged and nonsubmerged techniques. Factors such as implant length, site, and application of guided bone regeneration did not have an impact on the long-term success of the implants. © 2017 by the American College of Prosthodontists.

  2. The Effect of an Extreme and Prolonged Population Bottleneck on Patterns of Deleterious Variation: Insights from the Greenlandic Inuit.

    PubMed

    Pedersen, Casper-Emil T; Lohmueller, Kirk E; Grarup, Niels; Bjerregaard, Peter; Hansen, Torben; Siegismund, Hans R; Moltke, Ida; Albrechtsen, Anders

    2017-02-01

    The genetic consequences of population bottlenecks on patterns of deleterious genetic variation in human populations are of tremendous interest. Based on exome sequencing of 18 Greenlandic Inuit we show that the Inuit have undergone a severe ∼20,000-year-long bottleneck. This has led to a markedly more extreme distribution of allele frequencies than seen for any other human population tested to date, making the Inuit the perfect population for investigating the effect of a bottleneck on patterns of deleterious variation. When comparing proxies for genetic load that assume an additive effect of deleterious alleles, the Inuit show, at most, a slight increase in load compared to European, East Asian, and African populations. Specifically, we observe <4% increase in the number of derived deleterious alleles in the Inuit. In contrast, proxies for genetic load under a recessive model suggest that the Inuit have a significantly higher load (20% increase or more) compared to other less bottlenecked human populations. Forward simulations under realistic models of demography support our empirical findings, showing up to a 6% increase in the genetic load for the Inuit population across all models of dominance. Further, the Inuit population carries fewer deleterious variants than other human populations, but those that are present tend to be at higher frequency than in other populations. Overall, our results show how recent demographic history has affected patterns of deleterious variants in human populations. Copyright © 2017 by the Genetics Society of America.

  3. Consequences of long-term oral administration of the mitochondria-targeted antioxidant MitoQ to wild-type mice.

    PubMed

    Rodriguez-Cuenca, Sergio; Cochemé, Helena M; Logan, Angela; Abakumova, Irina; Prime, Tracy A; Rose, Claudia; Vidal-Puig, Antonio; Smith, Anthony C; Rubinsztein, David C; Fearnley, Ian M; Jones, Bruce A; Pope, Simon; Heales, Simon J R; Lam, Brian Y H; Neogi, Sudeshna Guha; McFarlane, Ian; James, Andrew M; Smith, Robin A J; Murphy, Michael P

    2010-01-01

    The mitochondria-targeted quinone MitoQ protects mitochondria in animal studies of pathologies in vivo and is being developed as a therapy for humans. However, it is unclear whether the protective action of MitoQ is entirely due to its antioxidant properties, because long-term MitoQ administration may alter whole-body metabolism and gene expression. To address this point, we administered high levels of MitoQ orally to wild-type C57BL/6 mice for up to 28 weeks and investigated the effects on whole-body physiology, metabolism, and gene expression, finding no measurable deleterious effects. In addition, because antioxidants can act as pro-oxidants under certain conditions in vitro, we examined the effects of MitoQ administration on markers of oxidative damage. There were no changes in the expression of mitochondrial or antioxidant genes as assessed by DNA microarray analysis. There were also no increases in oxidative damage to mitochondrial protein, DNA, or cardiolipin, and the activities of mitochondrial enzymes were unchanged. Therefore, MitoQ does not act as a pro-oxidant in vivo. These findings indicate that mitochondria-targeted antioxidants can be safely administered long-term to wild-type mice. Copyright 2009 Elsevier Inc. All rights reserved.

  4. Assessment of a press-fit proximal femoral modular reconstruction implant (PFMR®) at 14.5 years. A 48-case series with a disturbing rate of implant fracture.

    PubMed

    Dumoulin, Q; Sabau, S; Goetzmann, T; Jacquot, A; Sirveaux, F; Mole, D; Roche, O

    2018-05-01

    The PFMR ® proximal femoral modular reconstruction implant (Protek, Sulzer Orthopedics, Switzerland) is a straight modular stem in sanded titanium with press-fit anchorage, intended to achieve spontaneous bone reconstruction following Wagner's principle. The aim of the present study was to analyze long-term clinical and radiological outcome. A single-center retrospective study included 48 PFMR stems implanted in 47 patients between 1998 and 2002. Results in this series were previously reported at 7 years' follow-up. Clinical assessment used PMA and Harris scores. Radiologic assessment focused on stem stability and osseointegration, and bone stock following Le Béguec. Twenty-three patients were seen at a mean 14.5 years' follow-up (13 deceased, 11 lost to follow-up), including 1 with bilateral implants, i.e., 24 stems. PMA and Harris scores, stem stability and osseointegration and bone stock were stable with respect to the 7-year findings. Radiology found 7 stem fractures in the Morse taper, i.e., in 29% of implants. Two of these cases required femoral implant replacement; 5 were asymptomatic. Long-term outcome for PFMR stems was clinically and radiologically satisfactory for the 16 patients free of mechanical complications. The Morse taper fracture rate was high, and higher than reported elsewhere. The usual risk factors for implant fracture were not found in the present series. The modular design of the press-fit revision implant is its weak point; monoblock implants should be used in patients with good life-expectancy. IV (retrospective study). Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  5. Do ion levels in metal-on-metal hip resurfacing differ from those in metal-on-metal THA at long-term followup?

    PubMed

    Savarino, Lucia; Cadossi, Matteo; Chiarello, Eugenio; Baldini, Nicola; Giannini, Sandro

    2013-09-01

    Metal-on-metal hip resurfacing arthroplasty (MOM HR) has become an established alternative to traditional metal-on-metal total hip arthroplasty (MOM THA) for younger, more active patients. Nevertheless, concerns remain regarding wear and corrosion of the bearing surfaces and the resulting systemic metal ion distribution. We therefore asked whether (1) serum ion concentrations in patients with MOM HR at the time of long-term followup were higher than concentrations in a control population with no hip implants; (2) the ion concentrations in patients with MOM HR were different from those in patients with MOM THA; and (3) sex would influence ion levels with regard to implant type. The MOM HR and MOM THA groups consisted of 25 patients (evaluated at a minimum of 96 months) and 16 patients (evaluated at a minimum of 106 months), respectively. Forty-eight healthy donors were recruited for reference values. Cobalt, chromium, nickel, and molybdenum were measured by furnace graphite atomic absorption spectrophotometry. Ion concentrations of cobalt, chromium, and molybdenum in MOM HR were higher than in controls. Chromium and cobalt release were higher in MOM HR than in MOM THA. The sex-based analysis showed the difference was because women had higher concentrations in the MOM HR group than in the MOM THA group, whereas there was no difference between the men in the two groups. In MOM HR, high metal ion release persists for the long term. Consequently, it is important to implement strict biomonitoring for patients who have received these implants. The sustained high levels of chromium in females within the MOM HR group are concerning and merits strong consideration when choosing implants in this patient group.

  6. Business Students' Choice of Short-Term or Long-Term Study Abroad Opportunities

    ERIC Educational Resources Information Center

    Fitzsimmons, Stacey R.; Flanagan, David J.; Wang, Xiaodan

    2013-01-01

    Recent years have seen a proliferation of short-term study abroad opportunities. Although they are both supplementing and replacing semester-long study abroad programs, research has focused primarily on semester (long-term) programs. We draw on the theory of planned behavior (TPB) to explore factors that predict why students choose long-term and…

  7. Materials and technologies for soft implantable neuroprostheses

    NASA Astrophysics Data System (ADS)

    Lacour, Stéphanie P.; Courtine, Grégoire; Guck, Jochen

    2016-10-01

    Implantable neuroprostheses are engineered systems designed to restore or substitute function for individuals with neurological deficits or disabilities. These systems involve at least one uni- or bidirectional interface between a living neural tissue and a synthetic structure, through which information in the form of electrons, ions or photons flows. Despite a few notable exceptions, the clinical dissemination of implantable neuroprostheses remains limited, because many implants display inconsistent long-term stability and performance, and are ultimately rejected by the body. Intensive research is currently being conducted to untangle the complex interplay of failure mechanisms. In this Review, we emphasize the importance of minimizing the physical and mechanical mismatch between neural tissues and implantable interfaces. We explore possible materials solutions to design and manufacture neurointegrated prostheses, and outline their immense therapeutic potential.

  8. Therapeutic effects of N-acetyl-L-cysteine on liver damage induced by long-term CCl4 administration.

    PubMed

    Otrubová, Oľga; Turecký, Ladislav; Uličná, Oľga; Janega, Pavol; Luha, Ján; Muchová, Jana

    2018-01-01

    N-acetyl-L-cysteine (NAC) is a drug routinely used in several health problems, e.g. liver damage. There is some information emerged on its negative effects in certain situations. The aim of our study was to examine its ability to influence liver damage induced by long-term burden. We induced liver damage by CCl4 (10 weeks) and monitored the impact of parallel NAC administration (daily 150 mg/kg of b.w.) on liver morphology and some biochemical parameters (triacylglycerols, cholesterol, alanine aminotransferase (ALT), aspartate aminotransferase (AST), bilirubin, bile acids, proteins, albumins and cholinesterase). NAC significantly decreased levels of bile acids and bilirubin in plasma and triacylglycerols in liver, all of them elevated by impairment with CCl4. Reduction of cholesterol induced by CCl4 was completely recovered in the presence of NAC as indicated by its elevation to control levels. NAC administration did not improve the histological parameters. Together with protective effects of NAC, we found also its deleterious properties: parallel administration of CCl4 and NAC increased triacylglycerols, ALT and AST activity and significantly increased plasma cholinesterase activity. We have observed nonsignificantly increased percentage of liver tissue fibrosis. Our results have shown that NAC administered simultaneously with liver damaging agent CCl4, exhibits not only protective, but also deleterious effects as indicated by several biochemical parameters.

  9. A meta-analysis and meta-regression of long-term outcomes of transcatheter versus surgical aortic valve replacement for severe aortic stenosis.

    PubMed

    Villablanca, Pedro A; Mathew, Verghese; Thourani, Vinod H; Rodés-Cabau, Josep; Bangalore, Sripal; Makkiya, Mohammed; Vlismas, Peter; Briceno, David F; Slovut, David P; Taub, Cynthia C; McCarthy, Patrick M; Augoustides, John G; Ramakrishna, Harish

    2016-12-15

    Transcatheter aortic valve replacement (TAVR) has emerged as an alternative to surgical aortic-valve replacement (SAVR) for patients with severe symptomatic aortic stenosis (AS) who are at high operative risk. We sought to determine the long-term (≥1year follow-up) safety and efficacy TAVR compared with SAVR in patients with severe AS. A comprehensive search of PubMed, EMBASE, Cochrane Central Register of Controlled Trials, conference proceedings, and relevant Web sites from inception through 10 April 2016. Fifty studies enrolling 44,247 patients met the inclusion criteria. The mean duration follow-up was 21.4months. No difference was found in long-term all-cause mortality (risk ratios (RR), 1.06; 95% confidence interval (CI) 0.91-1.22). There was a significant difference favoring TAVR in the incidence of stroke (RR, 0.82; 95% CI 0.71-0.94), atrial fibrillation (RR, 0.43; 95% CI 0.33-0.54), acute kidney injury (RR, 0.70; 95% CI 0.53-0.92), and major bleeding (RR, 0.57; 95% CI 0.40-0.81). TAVR had significant higher incidence of vascular complications (RR, 2.90; 95% CI 1.87-4.49), aortic regurgitation (RR, 7.00; 95% CI 5.27-9.30), and pacemaker implantation (PPM) (RR, 2.02; 95% CI 1.51-2.68). TAVR demonstrated significantly lower stroke risk compared to SAVR in high-risk patients (RR, 1.49; 95% CI 1.06-2.10); no differences in PPM implantation were observed in intermediate-risk patients (RR, 1.68; 95% CI 0.94-3.00). In a meta-regression analysis, the effect of TAVR baseline clinical features did not affect the long-term all-cause mortality outcome. TAVR and SAVR showed similar long-term survival in patients with severe AS; with important differences in treatment-associated morbidity. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  10. Deleterious effects of recombination and possible nonrecombinatorial advantages of sex in a fungal model.

    PubMed

    López-Villavicencio, M; Debets, A J M; Slakhorst, M; Giraud, T; Schoustra, S E

    2013-09-01

    Why sexual reproduction is so prevalent in nature remains a major question in evolutionary biology. Most of the proposed advantages of sex rely on the benefits obtained from recombination. However, it is still unclear whether the conditions under which these recombinatorial benefits would be sufficient to maintain sex in the short term are met in nature. Our study addresses a largely overlooked hypothesis, proposing that sex could be maintained in the short term by advantages due to functions linked with sex, but not related to recombination. These advantages would be so essential that sex could not be lost in the short term. Here, we used the fungus Aspergillus nidulans to experimentally test predictions of this hypothesis. Specifically, we were interested in (i) the short-term deleterious effects of recombination, (ii) possible nonrecombinatorial advantages of sex particularly through the elimination of mutations and (iii) the outcrossing rate under choice conditions in a haploid fungus able to reproduce by both outcrossing and haploid selfing. Our results were consistent with our hypotheses: we found that (i) recombination can be strongly deleterious in the short term, (ii) sexual reproduction between individuals derived from the same clonal lineage provided nonrecombinatorial advantages, likely through a selection arena mechanism, and (iii) under choice conditions, outcrossing occurs in a homothallic species, although at low rates. © 2013 The Authors. Journal of Evolutionary Biology © 2013 European Society For Evolutionary Biology.

  11. Scalloped Implant-Abutment Connection Compared to Conventional Flat Implant-Abutment Connection: a Systematic Review and Meta-Analysis.

    PubMed

    Starch-Jensen, Thomas; Christensen, Ann-Eva; Lorenzen, Henning

    2017-01-01

    The objective was to test the hypothesis of no difference in implant treatment outcome after installation of implants with a scalloped implant-abutment connection compared to a flat implant-abutment connection. A MEDLINE (PubMed), Embase and Cochrane library search in combination with a hand-search of relevant journals was conducted. No language or year of publication restriction was applied. The search provided 298 titles. Three studies fulfilled the inclusion criteria. The included studies were characterized by low or moderate risk of bias. Survival of suprastructures has never been compared within the same study. High implant survival rate was reported in all the included studies. Significantly more peri-implant marginal bone loss, higher probing depth score, bleeding score and gingival score was observed around implants with a scalloped implant-abutment connection. There were no significant differences between the two treatment modalities regarding professional or patient-reported outcome measures. Meta-analysis disclosed a mean difference of peri-implant marginal bone loss of 1.56 mm (confidence interval: 0.87 to 2.25), indicating significant more bone loss around implants with a scalloped implant-abutment connection. A scalloped implant-abutment connection seems to be associated with higher peri-implant marginal bone loss compared to a flat implant-abutment connection. Therefore, the hypothesis of the present systematic review must be rejected. However, further long-term randomized controlled trials assessing implant treatment outcome with the two treatment modalities are needed before definite conclusions can be provided about the beneficial use of implants with a scalloped implant-abutment connection on preservation of the peri-implant marginal bone level.

  12. When is youths’ debt to society paid off? Examining the long-term consequences of juvenile incarceration for adult functioning

    PubMed Central

    Gilman, Amanda B.; Hill, Karl G.; Hawkins, J. David

    2015-01-01

    Purpose To examine the long-term consequences of juvenile incarceration on functioning in adulthood (ages 27–33). Methods Propensity score analysis was used to compare incarcerated youth with those who were never incarcerated in a subsample of individuals who had experienced at least one police contact in adolescence. Data were drawn from the Seattle Social Development Project (SSDP), a multiethnic, gender balanced community sample. Results Youth who were incarcerated in adolescence were more likely to experience incarceration at ages 27, 30, or 33, more likely to meet criteria for alcohol abuse or dependence, and more likely to be receiving public assistance than similar youth who were never incarcerated. Conclusions Results show that juvenile incarceration is not only ineffective at reducing criminal behavior later in life, but that there are also unintended consequences for incarceration beyond the criminal domain. Furthermore, it appears that once a youth becomes involved in the juvenile justice system, there is a higher likelihood that he/she will remain tethered to the criminal justice system through the transition to adulthood. Given these long-term deleterious outcomes, it is recommended that suitable alternatives to juvenile incarceration that do not jeopardize public safety be pursued. PMID:26052482

  13. Long-term Evaluation of Type 2 Thyroplasty with Titanium Bridges for Adductor Spasmodic Dysphonia.

    PubMed

    Sanuki, Tetsuji; Yumoto, Eiji

    2017-07-01

    Objectives Standard treatments of adductor spasmodic dysphonia (AdSD) provide temporary relief of symptoms. Type 2 thyroplasty offers a long-term solution; however, long-term voice outcome data are lacking. The objective of this study was to assess the long-term voice outcomes of type 2 thyroplasty with titanium bridges through use of a validated voice questionnaire. Study Design Case series with chart review. Setting University hospital. Subjects and Methods Forty-seven consecutively enrolled patients with AdSD underwent type 2 thyroplasty with titanium bridges between August 2006 and November 2014. Questionnaires were completed during regularly scheduled follow-ups and, in some cases, were sent to patients who missed follow-up appointments. In 2015, questionnaires were mailed to all 47 patients and included a Voice Handicap Index-10 evaluation, as well as questions on postoperative vocal symptoms, surgical site, and status of the implanted titanium bridges. Results Of 47 patients with AdSD, 31 (66%) completed the questionnaires. The average follow-up interval was 41.3 months. No patient reported experiencing an adverse event around the surgical site, and almost all were satisfied with their voices postoperatively. The mean postoperative (>3 years) Voice Handicap Index-10 score improved significantly, from 26.3 to 9.4 (n = 17, P = .0009). Conclusions Type 2 thyroplasty for AdSD significantly improved patient quality of life and voice symptoms and continued to do so long after the surgery. The results of this study suggest that type 2 thyroplasty provides relief from vocal symptoms in patients with AdSD for >3 years.

  14. Twenty-Seven Years Experience With Transvenous Pacemaker Implantation in Children Weighing <10 kg.

    PubMed

    Konta, Laura; Chubb, Mark Henry; Bostock, Julian; Rogers, Jan; Rosenthal, Eric

    2016-02-01

    Epicardial pacemaker implantation is the favored approach in children weighing <10 kg in many units. The high incidence of premature failure and fractures with earlier epicardial leads led our unit to undertake transvenous pacemaker implantation in neonates and infants from 1987. To date there have been no long-term follow-up reports of what is for many a controversial strategy. Between 1987 and 2003, 37 neonates and infants-median age 6.7 months (1 day to 3 years) and median weight 4.6 kg (2.7-10 kg)-had a permanent transvenous pacing system implanted. Pacing leads were placed into the right ventricular apex/outflow tract through a subclavian vein puncture with a redundant loop in the atrium. Three patients were lost to follow-up, 4 patients died from complications of cardiac surgery, and 2 patients had their system removed. At long-term follow-up in 28 patients at a median of 17.2 (range, 11.2-27.4) years, 10 patients have a single chamber ventricular pacemaker, 14 a dual chamber pacemaker, 3 a biventricular pacemaker, and 1 has a single chamber implantable cardioverter defibrillator. Subclavian vein patency was assessed in 26 patients. The overall subclavian vein occlusion rate was 10 of 13 (77%) <5 kg and 2 of 13 (15%) >5 kg during long-term follow-up. After a median of 14.3 (range, 13.4-17.6) years of pacing, 7 patients continue with their original lead. Transvenous pacing in infants <10 kg results in encouraging short- and long-term clinical outcomes. Subclavian vein occlusion remains an important complication, occurring predominantly in those weighing <5 kg. © 2016 American Heart Association, Inc.

  15. Falling Leaves Inspired ZnO Nanorods-Nanoslices Hierarchical Structure for Implant Surface Modification with Two Stage Releasing Features.

    PubMed

    Liao, Hang; Miao, Xinxin; Ye, Jing; Wu, Tianlong; Deng, Zhongbo; Li, Chen; Jia, Jingyu; Cheng, Xigao; Wang, Xiaolei

    2017-04-19

    Inspired from falling leaves, ZnO nanorods-nanoslices hierarchical structure (NHS) was constructed to modify the surfaces of two widely used implant materials: titanium (Ti) and tantalum (Ta), respectively. By which means, two-stage release of antibacterial active substances were realized to address the clinical importance of long-term broad-spectrum antibacterial activity. At early stages (within 48 h), the NHS exhibited a rapid releasing to kill the bacteria around the implant immediately. At a second stage (over 2 weeks), the NHS exhibited a slow releasing to realize long-term inhibition. The excellent antibacterial activity of ZnO NHS was confirmed once again by animal test in vivo. According to the subsequent experiments, the ZnO NHS coating exhibited the great advantage of high efficiency, low toxicity, and long-term durability, which could be a feasible manner to prevent the abuse of antibiotics on implant-related surgery.

  16. Long Periodic Terms in the Solar System

    NASA Technical Reports Server (NTRS)

    Bretagnon, P.

    1982-01-01

    The long period variations of the first eight planets in the solar system are studied. First, the Lagrangian solution is calculated and then the long period terms with fourth order eccentricities and inclinations are introduced into the perturbation function. A second approximation was made taking into account the short period terms' contribution, namely the perturbations of first order with respect to the masses. Special attention was paid to the determination of the integration constants. The relative importance of the different contributions is shown. It is useless, for example, to introduce the long period terms of fifth order if no account has been taken of the short period terms. Meanwhile, the terms that have been neglected would not introduce large changes in the integration constants. Even so, the calculation should be repeated with higher order short period terms and fifth order long periods.

  17. Long-Term Hearing Results After Ossiculoplasty.

    PubMed

    Cox, Matthew D; Trinidade, Aaron; Russell, James Shep; Dornhoffer, John L

    2017-04-01

    To determine if the OOPS index is predictive of long-term hearing results after ossiculoplasty. Case series with retrospective chart review. Tertiary care otology practice. Adult and pediatric patients (3-88 years of age). Ossiculoplasty with cartilage tympanoplasty, with or without mastoidectomy. Primary outcome measures included short-term hearing results (pure-tone average air-bone gap [PTA-ABG] measured between 60 days and 1 year after surgery), long-term hearing results (PTA-ABG measured ≥5 years after surgery), and the rate of successful ABG closure to ≤20 dB. Secondary measures included the need for revision surgery, delayed tympanic membrane graft failure, worsening conductive hearing loss (after an initially satisfactory hearing result), and recurrence of cholesteatoma. There was no significant difference between adults and children for short-term hearing results (average post-op PTA-ABG was 18.9 dB vs. 19.8 dB, respectively; p = 0.544), long-term hearing results (average final PTA-ABG was 19.3 dB vs. 19.4 dB, respectively; p = 0.922), or rate of ABG closure to less than 20 dB (63.1% vs. 58.0%, p = 0.282). Spearman's rank-order correlation (ρ) identified a strong positive correlation between OOPS index score and average post-operative PTA-ABG (ρ = 0.983; p < 0.001; 2-tailed), as well as average long-term PTA-ABG (ρ = 0.950, p < 0.001; 2-tailed). The OOPS index makes it possible to accurately prognosticate hearing outcomes in adult and pediatric patients undergoing ossiculoplasty in both the short term and the long term.

  18. Pacemakers and implantable cardioverter-defibrillators in pediatric patients.

    PubMed

    Silka, Michael J; Bar-Cohen, Yaniv

    2006-11-01

    The use of pacemakers and implantable cardioverter-defibrillators (ICDs) in infants, children, and patients with congenital heart disease presents unique challenges and considerations. They include uncommon indications for device implantation, innovative approaches to lead implantation and configuration, and age-dependent and disease-specific aspects of device programming. In this review, the current indications for pacemaker and ICD implantation in young patients are discussed, followed by consideration of the approaches to lead and device placement in very small patients and those with complex congenital heart disease, in whom unique problems may be encountered. The limitations of programmability of current pacemakers and ICDs when used in young patients are discussed, followed by an analysis of long-term device follow-up and potential late complications.

  19. Short-term memory and long-term memory are still different.

    PubMed

    Norris, Dennis

    2017-09-01

    A commonly expressed view is that short-term memory (STM) is nothing more than activated long-term memory. If true, this would overturn a central tenet of cognitive psychology-the idea that there are functionally and neurobiologically distinct short- and long-term stores. Here I present an updated case for a separation between short- and long-term stores, focusing on the computational demands placed on any STM system. STM must support memory for previously unencountered information, the storage of multiple tokens of the same type, and variable binding. None of these can be achieved simply by activating long-term memory. For example, even a simple sequence of digits such as "1, 3, 1" where there are 2 tokens of the digit "1" cannot be stored in the correct order simply by activating the representations of the digits "1" and "3" in LTM. I also review recent neuroimaging data that has been presented as evidence that STM is activated LTM and show that these data are exactly what one would expect to see based on a conventional 2-store view. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  20. Short-Term Memory and Long-Term Memory are Still Different

    PubMed Central

    2017-01-01

    A commonly expressed view is that short-term memory (STM) is nothing more than activated long-term memory. If true, this would overturn a central tenet of cognitive psychology—the idea that there are functionally and neurobiologically distinct short- and long-term stores. Here I present an updated case for a separation between short- and long-term stores, focusing on the computational demands placed on any STM system. STM must support memory for previously unencountered information, the storage of multiple tokens of the same type, and variable binding. None of these can be achieved simply by activating long-term memory. For example, even a simple sequence of digits such as “1, 3, 1” where there are 2 tokens of the digit “1” cannot be stored in the correct order simply by activating the representations of the digits “1” and “3” in LTM. I also review recent neuroimaging data that has been presented as evidence that STM is activated LTM and show that these data are exactly what one would expect to see based on a conventional 2-store view. PMID:28530428

  1. Long-Term Monitoring of Brain Dopamine Metabolism In Vivo with Carbon Paste Electrodes

    PubMed Central

    O'Neill, Robert D.

    2005-01-01

    This review focuses on the stability of voltammetric signals recorded over periods of months with carbon paste electrodes (CPEs) implanted in the brain. The key interaction underlying this stability is between the pasting oil and brain lipids that are capable of inhibiting the fouling caused by proteins. In brain regions receiving a significant dopaminergic input, a peak due to the methylated metabolites of dopamine, principally homovanillic acid (HVA), is clearly resolved using slow sweep voltammetry. Although a number of factors limit the time resolution for monitoring brain HVA concentration dynamics, the stability of CPEs allows investigations of long-term effects of drugs, as well as behavioral studies, not possible using other in-vivo monitoring techniques.

  2. Prophylactic antibiotics for preventing Gram positive infections associated with long-term central venous catheters in oncology patients.

    PubMed

    van de Wetering, Marianne D; van Woensel, Job B M; Lawrie, Theresa A

    2013-11-25

    This is an updated version of the review which was first published in the Cochrane Database of Systematic Reviews in 2006. Long-term central venous catheters (CVCs), including tunnelled CVCs (TCVCs) and totally implanted devices or ports (TIDs), are increasingly used when treating oncology patients. Despite international guidelines on sterile insertion and appropriate CVC maintenance and use, infection remains a common complication. These infections are mainly caused by Gram positive bacteria. Antimicrobial prevention strategies aimed at these micro-organisms could potentially decrease the majority of CVC infections. The aim of this review was to evaluate the efficacy of antibiotics in the prevention of Gram positive infections in long-term CVCs. To determine the efficacy of administering antibiotics prior to the insertion of long-term CVCs, or flushing or locking long-term CVCs with a combined antibiotic and heparin solution, or both, to prevent Gram positive catheter-related infections in adults and children receiving treatment for cancer. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (to June 2013) and the MEDLINE and EMBASE databases (1966 to 2013). Randomised controlled trials (RCTs) comparing prophylactic antibiotics given prior to long-term CVC insertion with no antibiotics, RCTs comparing a combined antibiotic and heparin solution with a heparin-only solution to flush or lock newly inserted long-term CVCs, and RCTs comparing a combination of these interventions in adults and children receiving treatment for cancer. Two authors independently selected studies, classified them and extracted data on to a pre-designed data collection form. We pooled data using the RevMan software version 5.2 and used random-effects (RE) model methods for meta-analyses. We included 11 trials with a total of 828 oncology patients (adults and children). We assessed most included studies to be at a low or unclear risk of bias. Five trials compared the use

  3. Nanotechnology for dental implants.

    PubMed

    Tomsia, Antoni P; Lee, Janice S; Wegst, Ulrike G K; Saiz, Eduardo

    2013-01-01

    With the advent of nanotechnology, an opportunity exists for the engineering of new dental implant materials. Metallic dental implants have been successfully used for decades, but they have shortcomings related to osseointegration and mechanical properties that do not match those of bone. Absent the development of an entirely new class of materials, faster osseointegration of currently available dental implants can be accomplished by various surface modifications. To date, there is no consensus regarding the preferred method(s) of implant surface modification, and further development will be required before the ideal implant surface can be created, let alone become available for clinical use. Current approaches can generally be categorized into three areas: ceramic coatings, surface functionalization, and patterning on the micro- to nanoscale. The distinctions among these are imprecise, as some or all of these approaches can be combined to improve in vivo implant performance. These surface improvements have resulted in durable implants with a high percentage of success and long-term function. Nanotechnology has provided another set of opportunities for the manipulation of implant surfaces in its capacity to mimic the surface topography formed by extracellular matrix components of natural tissue. The possibilities introduced by nanotechnology now permit the tailoring of implant chemistry and structure with an unprecedented degree of control. For the first time, tools are available that can be used to manipulate the physicochemical environment and monitor key cellular events at the molecular level. These new tools and capabilities will result in faster bone formation, reduced healing time, and rapid recovery to function.

  4. Mechanical characterization and numerical simulation of a subcutaneous implantable 3D printed cell encapsulation system.

    PubMed

    Adamo, Federica; Farina, Marco; Thekkedath, Usha R; Grattoni, Alessandro; Sesana, Raffaella

    2018-06-01

    Cell transplantation in bioengineered scaffolds and encapsulation systems has shown great promise in regenerative medicine. Depending on the site of implantation, type of cells and their expected function, these systems are designed to provide cells with a physiological-like environment while providing mechanical support and promoting long-term viability and function of the graft. A minimally invasive 3D printed system termed neovascularized implantable cell homing and encapsulation (NICHE) was developed in polylactic acid for subcutaneous transplantation of endocrine cells, including pancreatic islets. The suitability of the NICHE for long term in vivo deployment is investigated by assessing mechanical behavior of both fresh devices under simulated subcutaneous conditions and NICHE retrieved from subcutaneous implantation in pigs. Both experimental and numerical studies were performed with a focus on validating the constitutive material model used in the numerical analysis for accuracy and reliability. Notably, homogeneous isotropic constitutive material model calibrated by means of uniaxial testing well suited experimental results. The results highlight the long term durability for in vivo applications and the potential applicability of the model to predict the mechanical behavior of similar devices in various physiological settings. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. Divergent short- and long-term effects of acute stress in object recognition memory are mediated by endogenous opioid system activation.

    PubMed

    Nava-Mesa, Mauricio O; Lamprea, Marisol R; Múnera, Alejandro

    2013-11-01

    Acute stress induces short-term object recognition memory impairment and elicits endogenous opioid system activation. The aim of this study was thus to evaluate whether opiate system activation mediates the acute stress-induced object recognition memory changes. Adult male Wistar rats were trained in an object recognition task designed to test both short- and long-term memory. Subjects were randomly assigned to receive an intraperitoneal injection of saline, 1 mg/kg naltrexone or 3 mg/kg naltrexone, four and a half hours before the sample trial. Five minutes after the injection, half the subjects were submitted to movement restraint during four hours while the other half remained in their home cages. Non-stressed subjects receiving saline (control) performed adequately during the short-term memory test, while stressed subjects receiving saline displayed impaired performance. Naltrexone prevented such deleterious effect, in spite of the fact that it had no intrinsic effect on short-term object recognition memory. Stressed subjects receiving saline and non-stressed subjects receiving naltrexone performed adequately during the long-term memory test; however, control subjects as well as stressed subjects receiving a high dose of naltrexone performed poorly. Control subjects' dissociated performance during both memory tests suggests that the short-term memory test induced a retroactive interference effect mediated through light opioid system activation; such effect was prevented either by low dose naltrexone administration or by strongly activating the opioid system through acute stress. Both short-term memory retrieval impairment and long-term memory improvement observed in stressed subjects may have been mediated through strong opioid system activation, since they were prevented by high dose naltrexone administration. Therefore, the activation of the opioid system plays a dual modulating role in object recognition memory. Copyright © 2013 Elsevier Inc. All rights

  6. XEN Gel Implant: a new surgical approach in glaucoma.

    PubMed

    Chaudhary, Ankita; Salinas, Lauriane; Guidotti, Jacopo; Mermoud, André; Mansouri, Kaweh

    2018-01-01

    Glaucoma is a leading cause of blindness worldwide. Intraocular pressure (IOP) lowering is the only effective treatment strategy. Traditional glaucoma surgeries are generally considered to be unpredictable and associated with a high rate of complications. This has led to the development of a novel XEN Gel Implant, a type of minimally invasive glaucoma surgery (MIGS), lowering the IOP without extensive surgical dissection. Areas covered: A literature search was undertaken on PubMed using the terms XEN glaucoma, gelatin microstent, and MIGS. All the articles and case reports on XEN Gel Implant and selected articles on MIGS were studied and reviewed. We have discussed the results of most studies on XEN Gel Implant related to its efficacy, safety and success. Expert commentary: The XEN Gel Implant effectively lowers IOP and medication use, with a favorable safety profile. Long-term data on its success and cost-effectiveness are lacking. The studies have shown it to be without any serious adverse events and to have good safety profile encouraging future research on this novel implant. There is a need to correctly identify selection criteria for patients, who would benefit the most from the XEN Gel Implant.

  7. Oral Effects and Early Implant Survival Results After Imatinib Discontinuation Therapy for Chronic Myelogenous Leukemia: A Case Report.

    PubMed

    Dixon, Douglas R; Yassin, Alaa

    2017-08-01

    Little is known regarding the success, failure, or complication rates of advanced implant procedures in patients after discontinuation therapy of long-term medications for the treatment of chronic myelogenous leukemia (CML). This case report presents initial results of a case involving implant placement in the mandible and maxilla as well as reduction of palatal oral pigmentation in a patient discontinuing long-term tyrosine kinase inhibitor (TKI) therapy for CML. A 57-year-old male was referred to the Department of Periodontics, University of Washington, Seattle, Washington, for an assessment of edentulous areas (tooth sites #3 and #14) and failing tooth #19. Previous medical treatment included oral administration (>10 years) of TKI for the treatment of CML. Systemic complications arising from long-term TKI therapy were treated with discontinuation of this medication. Concurrently, after multispecialty dental and medical consultation, extraction of tooth #19 with immediate implant placement and bilateral sinus augmentation with simultaneous implant placement were successfully performed during three separate surgical appointments. Additionally, marked reduction of oral palatal pigmentation was observed during the surgical and restorative phases after TKI discontinuation. Patients with a history of long-term TKIs for CML are at risk for developing complications that result in discontinuation of therapy. Long-term benefits of therapy may allow these patients to enjoy remission with an extended and improved quality of life. Patients undergoing discontinuation therapy may seek dental care. Therefore, dental providers need to understand these systemic interactions and, with multispecialty consultation, may help effectively treat these individuals.

  8. Designer Dual Therapy Nanolayered Implant Coatings Eradicate Biofilms and Accelerate Bone Tissue Repair.

    PubMed

    Min, Jouha; Choi, Ki Young; Dreaden, Erik C; Padera, Robert F; Braatz, Richard D; Spector, Myron; Hammond, Paula T

    2016-04-26

    Infections associated with orthopedic implants cause increased morbidity and significant healthcare cost. A prolonged and expensive two-stage procedure requiring two surgical steps and a 6-8 week period of joint immobilization exists as today's gold standard for the revision arthroplasty of an infected prosthesis. Because infection is much more common in implant replacement surgeries, these issues greatly impact long-term patient care for a continually growing part of the population. Here, we demonstrate that a single-stage revision using prostheses coated with self-assembled, hydrolytically degradable multilayers that sequentially deliver the antibiotic (gentamicin) and the osteoinductive growth factor (BMP-2) in a time-staggered manner enables both eradication of established biofilms and complete and rapid bone tissue repair around the implant in rats with induced osteomyelitis. The nanolayered construct allows precise independent control of release kinetics and loading for each therapeutic agent in an infected implant environment. Antibiotics contained in top layers can be tuned to provide a rapid release at early times sufficient to eliminate infection, followed by sustained release for several weeks, and the underlying BMP-2 component enables a long-term sustained release of BMP-2, which induced more significant and mechanically competent bone formation than a short-term burst release. The successful growth factor-mediated osteointegration of the multilayered implants with the host tissue improved bone-implant interfacial strength 15-fold when compared with the uncoated one. These findings demonstrate the potential of this layered release strategy to introduce a durable next-generation implant solution, ultimately an important step forward to future large animal models toward the clinic.

  9. Orbital implant exposure treatment with porcine dermal collagen patching.

    PubMed

    Alwitry, A; Burns, S J; Abercrombie, L C

    2006-09-01

    To present a small case series of orbital implant exposures treated with porcine dermal collagen (Permacol, Tissue Science Laboratories PLC, Aldershot, Hants, UK) patching. A retrospective chart review of three cases of orbital implant exposure treated with Permacol patching. Three cases were identified. There were 4 operative episodes of Permacol patching (one socket had two attempts at permacol patching). In all 4 cases the patch rapidly failed and melted away leaving behind the orbital implant exposure. All 3 patients required implant removal. Orbital implant exposure remains a major long-term complication of evisceration and enucleation procedures. On the basis of our experience, we would not recommend using Permacol as a non-autologous material for covering exposed Medpor (Medpor, Porex Surgical, Atlanta, Georgia, USA) orbital implants. Further study is required to fully assess the safety and efficacy profile of Permacol in socket surgery.

  10. Long-Term Memory Performance in Adult ADHD.

    PubMed

    Skodzik, Timo; Holling, Heinz; Pedersen, Anya

    2017-02-01

    Memory problems are a frequently reported symptom in adult ADHD, and it is well-documented that adults with ADHD perform poorly on long-term memory tests. However, the cause of this effect is still controversial. The present meta-analysis examined underlying mechanisms that may lead to long-term memory impairments in adult ADHD. We performed separate meta-analyses of measures of memory acquisition and long-term memory using both verbal and visual memory tests. In addition, the influence of potential moderator variables was examined. Adults with ADHD performed significantly worse than controls on verbal but not on visual long-term memory and memory acquisition subtests. The long-term memory deficit was strongly statistically related to the memory acquisition deficit. In contrast, no retrieval problems were observable. Our results suggest that memory deficits in adult ADHD reflect a learning deficit induced at the stage of encoding. Implications for clinical and research settings are presented.

  11. Design of Composite Hip Prostheses Considering the Long-Term Behavior of the Femur

    NASA Astrophysics Data System (ADS)

    Lim, Jong Wan; Jeong, Jae Youn; Ha, Sung Kyu

    A design method for the hip prosthesis is proposed which can alleviate problems associated with stress shielding, proximal loosening and the high stress of bone-implant interfaces after total hip replacement. The stress shielding which may lead to bone resorption, can cause a loosening of the stem and a fracture of femoral bone. Generally the composites were more suitable for hip prosthesis material in the long-term stability than metallic alloy because design cases of composite materials produced less stress shielding than titanium alloy. A bone remodeling algorithm was implemented in a nonlinear finite element program to predict the long-term performance of the hip prosthesis. The three neck shapes and three cross sections of composite hip were examined. It was found that the stress concentration in the distal region of the titanium stem which may cause the patient's thigh pains was reduced using composite material. The head neck shape was closely related with the cortical bone resorption and the cancellous bone apposition at proximal region whereas the cross-section was closely related with the relative micromotion between interfaces. The convex head neck type with the quadrangle cross-section produced less subsidence at proximal region on the medial side than the others. For all composite material cases, the cancellous bone apposition occurred at partial interfaces, which may result in a stable bio-fixation. The design performances of the convex neck head type with the hexagonal cross-section designed to insure the long-term stability were found to be more suitable than the others.

  12. Prosthetic implant treatment of the edentulous maxilla with overdenture.

    PubMed

    Inversini, M

    2006-10-01

    The literature concerning the success of prosthetic implant treatment with maxillary overdenture is reviewed, and variables affecting treatment from the implant and prosthetic standpoint are analysed. Guidelines for the fabrication of maxillary overimplants comparable to those for mandibular overimplants are still lacking, as are evidence-based prosthetic design concepts. Individual methods and techniques have been described, but evaluation standards for the outcome of maxillary prosthetic-implant treatment are lacking or individually interpreted. The biomechanics involved in the proposed system are described, together with the advantages of telescopic crowns for the retention of removable partial prosthesis supported by maxillary implants. The positive influence, in terms of long-term prognosis, of the perio-protective design of removable partial prostheses supported by maxillary overimplants is also discussed. The proposed system not only provides stability, support and retention for removable partial prostheses supported by maxillary implants, but also enables implant survival rates to be improved, both for biomechanical reasons and due to improved oral hygiene. The simplification of fabrication procedures, repair, rebasing and re-operating also reduce the cost of follow-up and improve the cost/benefit ratio. However, additional studies are needed to clarify the number and most appropriate distribution of implants, as well as the most favourable prosthetic designs for maxillary overimplants.

  13. Virtual Models of Long-Term Care

    ERIC Educational Resources Information Center

    Phenice, Lillian A.; Griffore, Robert J.

    2012-01-01

    Nursing homes, assisted living facilities and home-care organizations, use web sites to describe their services to potential consumers. This virtual ethnographic study developed models representing how potential consumers may understand this information using data from web sites of 69 long-term-care providers. The content of long-term-care web…

  14. Long-term follow-up of autologous pericardial valved conduits.

    PubMed

    Schlichter, A J; Kreutzer, C; Mayorquim, R C; Simon, J L; Vazquez, H; Roman, M I; Kreutzer, G O

    1996-07-01

    The aim of this study was to evaluate the long-term results of the use of an autologous pericardial valved conduit in the outflow tract of the venous ventricle in congenital heart malformations. Fifty-one patients were followed up for a period of 12 to 120 months; 30 for more than 36 months and 13 for more than 72 months. All were evaluated clinically and by two-dimensional and Doppler echocardiography. Eight patients were recatheterized. Postoperative evaluation included serial measurement of pressure gradients and the conduit's diameter at the proximal, valvular, and distal levels. Reoperation because of stenosis was indicated when the gradient across the right ventricular outflow was greater than 50 mm Hg. The reoperation rate in relation with postoperative time, diameter of the autologous pericardial valved conduit at the time of implantation, and malformation was statistically analyzed. In 27 patients the conduit increased its diameter 1 to 7 mm. In 20 patients the diameter remained unchanged, whereas a reduction was noted in 4. Conduit survival free of reoperation for the whole group was 89.9% at 5 years. Conduit survival free of reoperation was 100% at 5 and 7 years for conduits larger than 16 mm at the time of implantation. It was 95% (standard deviation = 4.8%) at 5 years and 72.3% at 7 years for those 16 mm or less. For patients operated after January 1, 1986 (technical modification), conduit survival free of reoperation was 95.4% at 7 years postoperatively. These results compare favorably with those of other available conduits.

  15. Long-Term Biostability of Self-Assembling Protein Polymers in the Absence of Covalent Crosslinking

    PubMed Central

    Sallach, Rory E.; Cui, Wanxing; Balderrama, Fanor; Martinez, Adam W.; Wen, Jing; Haller, Carolyn A.; Taylor, Jeannette V.; Wright, Elizabeth R.; Long, Robert C.; Chaikof, Elliot L.

    2009-01-01

    Unless chemically crosslinked, matrix proteins, such as collagen or silk, display a limited lifetime in vivo with significant degradation observed over a period of weeks. Likewise, amphiphilic peptides, lipopeptides, or glycolipids that self-assemble through hydrophobic interactions to form thin films, fiber networks, or vesicles do not demonstrate in vivo biostability beyond a few days. We report herein that a self-assembling, recombinant elastin-mimetic triblock copolymer elicited minimal inflammatory response and displayed robust in vivo stability for periods exceeding 1 year, in the absence of either chemical or ionic crosslinking. Specifically, neither a significant inflammatory response nor calcification was observed upon implantation of test materials into the peritoneal cavity or subcutaneous space of a mouse model. Moreover, serial quantitative magnetic resonance imaging, evaluation of pre- and post-explant ultrastructure by cryo-high resolution scanning electron microscopy, and an examination of implant mechanical responses revealed substantial preservation of form, material architecture, and biomechanical properties, providing convincing evidence of a non-chemically or ionically crosslinked protein polymer system that exhibits long-term stability in vivo. PMID:19854505

  16. Prevalence of Long-Term Opioid Use in Long-Stay Nursing Home Residents.

    PubMed

    Hunnicutt, Jacob N; Chrysanthopoulou, Stavroula A; Ulbricht, Christine M; Hume, Anne L; Tjia, Jennifer; Lapane, Kate L

    2018-01-01

    Overall and long-term opioid use among older adults have increased since 1999. Less is known about opioid use in older adults in nursing homes (NHs). Cross-sectional. U.S. NHs (N = 13,522). Long-stay NH resident Medicare beneficiaries with a Minimum Data Set 3.0 (MDS) assessment between April 1, 2012, and June 30, 2012, and 120 days of follow-up (N = 315,949). We used Medicare Part D claims to measure length of opioid use in the 120 days from the index assessment (short-term: ≤30 days, medium-term: >30-89 days, long-term: ≥90 days), adjuvants (e.g., anticonvulsants), and other pain medications (e.g., corticosteroids). MDS assessments in the follow-up period were used to measure nonpharmacological pain management use. Modified Poisson models were used to estimate adjusted prevalence ratios (aPR) and 95% confidence intervals (CI) for age, gender, race and ethnicity, cognitive and physical impairment, and long-term opioid use. Of all long-stay residents, 32.4% were prescribed any opioid, and 15.5% were prescribed opioids long-term. Opioid users (versus nonusers) were more commonly prescribed pain adjuvants (32.9% vs 14.9%), other pain medications (25.5% vs 11.0%), and nonpharmacological pain management (24.5% vs 9.3%). Long-term opioid use was higher in women (aPR = 1.21, 95% CI = 1.18-1.23) and lower in racial and ethnic minorities (non-Hispanic blacks vs whites: APR = 0.93, 95% CI = 0.90-0.94) and those with severe cognitive impairment (vs no or mild impairment, aPR = 0.82, 95% CI = 0.79-0.83). One in seven NH residents was prescribed opioids long-term. Recent guidelines on opioid prescribing for pain recommend reducing long-term opioid use, but this is challenging in NHs because residents may not benefit from nonpharmacological and nonopioid interventions. Studies to address concerns about opioid safety and effectiveness (e.g., on pain and functional status) in NHs are needed. © 2017, Copyright the Authors Journal compilation © 2017, The American Geriatrics

  17. A comparison of the accuracy of polyether, polyvinyl siloxane, and plaster impressions for long-span implant-supported prostheses.

    PubMed

    Hoods-Moonsammy, Vyonne J; Owen, Peter; Howes, Dale G

    2014-01-01

    The purpose of this study was to compare the capacity of different impression materials to accurately reproduce the positions of five implant analogs on a master model by comparing the resulting cast with the stainless steel master model. The study was motivated by the knowledge that distortions can occur during impression making and the pouring of casts and that this distortion may produce inaccuracies of subsequent restorations, especially long-span castings for implant superstructures. The master model was a stainless steel model with five implant analogs. The impression materials used were impression plaster (Plastogum, Harry J Bosworth), a polyether (Impregum Penta, 3M ESPE), and two polyvinyl siloxane (PVS) materials (Aquasil Monophase and Aquasil putty with light-body wash, Dentsply). Five impressions were made with each impression material and cast in die stone under strictly controlled laboratory conditions. The positions of the implants on the master model, the impression copings, and the implant analogs in the subsequent casts were measured using a coordinate measuring machine that measures within 4 μm of accuracy. Statistical analyses indicated that distortion occurred in all of the impression materials, but inconsistently. The PVS monophase material reproduced the master model most accurately. Although there was no significant distortion between the impressions and the master model or between the impressions and their casts, there were distortions between the master model and the master casts, which highlighted the cumulative effects of the distortions. The polyether material proved to be the most reliable in terms of predictability. The impression plaster displayed cumulative distortion, and the PVS putty with light body showed the least reliability. Some of the distortions observed are of clinical significance and likely to contribute to a lack of passive fit of any superstructure. The inaccuracy of these analog materials and procedures suggested

  18. Prosthodontic perspective to all-on-4® concept for dental implants.

    PubMed

    Taruna, M; Chittaranjan, B; Sudheer, N; Tella, Suchita; Abusaad, Md

    2014-10-01

    The clinical success and longevity of endosteal dental implants as load bearing abutments are controlled largely by the mechanical setting in which they function. The treatment plan is responsible for the design, number and position of the implants. In biomechanically compromised environment such as poor quality bone, strain to the crestal bone can be reduced by increasing the anterioposterior spread of implants, placement of longer implants and maximizing the number of implants. The All-on-4(®) concept is one such treatment procedure which enlightens us for its use in the completely edentulous patients and which also leaves behind the routine treatment alternative of conventional dentures with successful outcome in the short term, long term and the retrospective studies that have been done in the past. The area of concern for any treatment alternative lies in the success of the prosthesis and its prosthodontic perspective involving the principles of occlusion. This article reviews the All-on-4(®) concept and its prosthodontic aspects.

  19. Prosthodontic Perspective to All-On-4® Concept for Dental Implants

    PubMed Central

    Chittaranjan, B; Sudheer, N; Tella, Suchita; Abusaad, Md.

    2014-01-01

    The clinical success and longevity of endosteal dental implants as load bearing abutments are controlled largely by the mechanical setting in which they function. The treatment plan is responsible for the design, number and position of the implants. In biomechanically compromised environment such as poor quality bone, strain to the crestal bone can be reduced by increasing the anterioposterior spread of implants, placement of longer implants and maximizing the number of implants. The All-on-4® concept is one such treatment procedure which enlightens us for its use in the completely edentulous patients and which also leaves behind the routine treatment alternative of conventional dentures with successful outcome in the short term, long term and the retrospective studies that have been done in the past. The area of concern for any treatment alternative lies in the success of the prosthesis and its prosthodontic perspective involving the principles of occlusion. This article reviews the All-on-4® concept and its prosthodontic aspects. PMID:25478475

  20. Assessment of modified gold surfaced titanium implants on skeletal fixation

    PubMed Central

    Zainali, Kasra; Danscher, Gorm; Jakobsen, Thomas; Baas, Jorgen; Møller, Per; Bechtold, Joan E.; Soballe, Kjeld

    2013-01-01

    Noncemented implants are the primary choice for younger patients undergoing total hip replacements. However, the major concern in this group of patients regarding revision is the concern from wear particles, periimplant inflammation, and subsequently aseptic implant loosening. Macrophages have been shown to liberate gold ions through the process termed dissolucytosis. Furthermore, gold ions are known to act in an anti-inflammatory manner by inhibiting cellular NF-κB-DNA binding. The present study investigated whether partial coating of titanium implants could augment early osseointegration and increase mechanical fixation. Cylindrical porous coated Ti-6Al-4V implants partially coated with metallic gold were inserted in the proximal region of the humerus in ten canines and control implants without gold were inserted in contralateral humerus. Observation time was 4 weeks. Biomechanical push out tests and stereological histomorphometrical analyses showed no statistically significant differences in the two groups. The unchanged parameters are considered an improvement of the coating properties, as a previous complete gold-coated implant showed inferior mechanical fixation and reduced osseointegration compared to control titanium implants in a similar model. Since sufficient early mechanical fixation is achieved with this new coating, it is reasonable to investigate the implant further in long-term studies. PMID:22847873

  1. Assessment of modified gold surfaced titanium implants on skeletal fixation.

    PubMed

    Zainali, Kasra; Danscher, Gorm; Jakobsen, Thomas; Baas, Jorgen; Møller, Per; Bechtold, Joan E; Soballe, Kjeld

    2013-01-01

    Noncemented implants are the primary choice for younger patients undergoing total hip replacements. However, the major concern in this group of patients regarding revision is the concern from wear particles, periimplant inflammation, and subsequently aseptic implant loosening. Macrophages have been shown to liberate gold ions through the process termed dissolucytosis. Furthermore, gold ions are known to act in an anti-inflammatory manner by inhibiting cellular NF-κB-DNA binding. The present study investigated whether partial coating of titanium implants could augment early osseointegration and increase mechanical fixation. Cylindrical porous coated Ti-6Al-4V implants partially coated with metallic gold were inserted in the proximal region of the humerus in ten canines and control implants without gold were inserted in contralateral humerus. Observation time was 4 weeks. Biomechanical push out tests and stereological histomorphometrical analyses showed no statistically significant differences in the two groups. The unchanged parameters are considered an improvement of the coating properties, as a previous complete gold-coated implant showed inferior mechanical fixation and reduced osseointegration compared to control titanium implants in a similar model. Since sufficient early mechanical fixation is achieved with this new coating, it is reasonable to investigate the implant further in long-term studies. Copyright © 2012 Wiley Periodicals, Inc.

  2. Cell-based neurotrophin treatment supports long-term auditory neuron survival in the deaf guinea pig.

    PubMed

    Gillespie, Lisa N; Zanin, Mark P; Shepherd, Robert K

    2015-01-28

    The cochlear implant provides auditory cues to profoundly deaf patients by electrically stimulating the primary auditory neurons (ANs) of the cochlea. However, ANs degenerate in deafness; the preservation of a robust AN target population, in combination with advances in cochlear implant technology, may provide improved hearing outcomes for cochlear implant patients. The exogenous delivery of neurotrophins such as brain-derived neurotrophic factor (BDNF) and neurotrophin-3 is well known to support AN survival in deafness, and cell-based therapies provide a potential clinically viable option for delivering neurotrophins into the deaf cochlea. This study utilized cells that were genetically modified to express BDNF and encapsulated in alginate microspheres, and investigated AN survival in the deaf guinea pig following (a) cell-based neurotrophin treatment in conjunction with chronic electrical stimulation from a cochlear implant, and (b) long-term cell-based neurotrophin delivery. In comparison to deafened controls, there was significantly greater AN survival following the cell-based neurotrophin treatment, and there were ongoing survival effects for at least six months. In addition, functional benefits were observed following cell-based neurotrophin treatment and chronic electrical stimulation, with a statistically significant decrease in electrically evoked auditory brainstem response thresholds observed during the experimental period. This study demonstrates that cell-based therapies, in conjunction with a cochlear implant, shows potential as a clinically transferable means of providing neurotrophin treatment to support AN survival in deafness. This technology also has the potential to deliver other therapeutic agents, and to be used in conjunction with other biomedical devices for the treatment of a variety of neurodegenerative conditions. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Complex network structure influences processing in long-term and short-term memory.

    PubMed

    Vitevitch, Michael S; Chan, Kit Ying; Roodenrys, Steven

    2012-07-01

    Complex networks describe how entities in systems interact; the structure of such networks is argued to influence processing. One measure of network structure, clustering coefficient, C, measures the extent to which neighbors of a node are also neighbors of each other. Previous psycholinguistic experiments found that the C of phonological word-forms influenced retrieval from the mental lexicon (that portion of long-term memory dedicated to language) during the on-line recognition and production of spoken words. In the present study we examined how network structure influences other retrieval processes in long- and short-term memory. In a false-memory task-examining long-term memory-participants falsely recognized more words with low- than high-C. In a recognition memory task-examining veridical memories in long-term memory-participants correctly recognized more words with low- than high-C. However, participants in a serial recall task-examining redintegration in short-term memory-recalled lists comprised of high-C words more accurately than lists comprised of low-C words. These results demonstrate that network structure influences cognitive processes associated with several forms of memory including lexical, long-term, and short-term.

  4. Long-term functional outcomes after artificial urinary sphincter implantation in men with stress urinary incontinence.

    PubMed

    Léon, Priscilla; Chartier-Kastler, Emmanuel; Rouprêt, Morgan; Ambrogi, Vanina; Mozer, Pierre; Phé, Véronique

    2015-06-01

    To evaluate long-term functional outcomes of artificial urinary sphincters (AUSs) and to determine how many men required explantation because of stress urinary incontinence (SUI) caused by sphincter deficiency after prostate surgery. Men who had undergone placement of an AUS (American Medical Systems AMS 800®) between 1984 and 1992 to relieve SUI caused by sphincter deficiency after prostate surgery were included. Continence, defined as no need for pads, was assessed at the end of the follow-up. Kaplan-Meier survival curves estimated the survival rate of the device without needing explantation or revision. In all, 57 consecutive patients were included with a median (interquartile range, IQR) age of 69 (64-72) years. The median (IQR) duration of follow-up was 15 (8.25-19.75) years. At the end of follow-up, 25 patients (43.8%) still had their primary AUS. The AUS was explanted in nine men because of erosion (seven) and infection (two). Survival rates, without AUS explantation, were 87%, 87%, 80%, and 80% at 5, 10, 15, and 20 years, respectively. Survival rates, without AUS revision, were 59%, 28%, 15%, and 5% at 5, 10, 15, and 20 years, respectively. At the end of the follow-up, in intention-to-treat analysis, 77.2% of patients were continent. In the long term (>10 years) the AMS 800 can offer a high rate of continence to men with SUI caused by sphincter deficiency, with a tolerable rate of explantation and revision. © 2014 The Authors. BJU International © 2014 BJU International.

  5. Effect of PlA1/A2 glycoprotein IIIa gene polymorphism on the long-term outcome after successful coronary stenting

    PubMed Central

    Le Hello, Claire; Morello, Rémy; Lequerrec, Agnès; Duarte, Christine; Riddell, John; Hamon, Martial

    2007-01-01

    Aim To prospectively determine the role of platelet glycoprotein IIIa (GP IIIa) gene PlA1/PlA2 polymorphism on the long-term clinical outcome in patients with coronary artery disease undergoing coronary stenting. Design and setting Prospective observational study in the University Hospital of Caen (France). Patients and methods 1 111 symptomatic consecutive Caucasian patients treated with percutaneous coronary intervention including stent implantation underwent genotyping for GP IIIa PlA1/A2. Main outcome measures Long-term clinical outcome in terms of the rate of major adverse cardiac events (MACE, ie death from any cause, non-fatal Q wave or non Q wave myocardial infarction, and need for coronary revascularisation) was obtained and subsequently stratified according to the GP IIIa PlA1/A2 polymorphism. Results Three groups of patients were determined according to the GP IIIa PlA1/A2 polymorphism (71.6% had the A1/A1, 25.8% had the A1/A2 and 2.6% had the A2/A2 genotype). These three groups were comparable for all clinical characteristics including sex ratio, mean age, vascular risk factors, previous coronary events, baseline angiographic exam, indication for the percutaneous coronary intervention and drug therapy). The incidence of MACE was similar in these 3 groups of patients during a mean follow-up period of 654+/-152 days. Independent risk factors for MACE were a left ventricular ejection fraction < 40%, absence of treatment with a beta-blocker and absence of treatment with an angiotensin converting enzyme inhibitor during follow-up. Conclusion The GP IIIa PlA1/A2 polymorphism does not influence the clinical long-term outcome in patients with symptomatic coronary disease undergoing percutaneous coronary intervention with stent implantation. PMID:18021403

  6. Scalloped Implant-Abutment Connection Compared to Conventional Flat Implant-Abutment Connection: a Systematic Review and Meta-Analysis

    PubMed Central

    Christensen, Ann-Eva; Lorenzen, Henning

    2017-01-01

    ABSTRACT Objectives The objective was to test the hypothesis of no difference in implant treatment outcome after installation of implants with a scalloped implant-abutment connection compared to a flat implant-abutment connection. Material and Methods A MEDLINE (PubMed), Embase and Cochrane library search in combination with a hand-search of relevant journals was conducted. No language or year of publication restriction was applied. Results The search provided 298 titles. Three studies fulfilled the inclusion criteria. The included studies were characterized by low or moderate risk of bias. Survival of suprastructures has never been compared within the same study. High implant survival rate was reported in all the included studies. Significantly more peri-implant marginal bone loss, higher probing depth score, bleeding score and gingival score was observed around implants with a scalloped implant-abutment connection. There were no significant differences between the two treatment modalities regarding professional or patient-reported outcome measures. Meta-analysis disclosed a mean difference of peri-implant marginal bone loss of 1.56 mm (confidence interval: 0.87 to 2.25), indicating significant more bone loss around implants with a scalloped implant-abutment connection. Conclusions A scalloped implant-abutment connection seems to be associated with higher peri-implant marginal bone loss compared to a flat implant-abutment connection. Therefore, the hypothesis of the present systematic review must be rejected. However, further long-term randomized controlled trials assessing implant treatment outcome with the two treatment modalities are needed before definite conclusions can be provided about the beneficial use of implants with a scalloped implant-abutment connection on preservation of the peri-implant marginal bone level. PMID:28496962

  7. Long-term outcomes of acute kidney injury.

    PubMed

    Coca, Steven G

    2010-05-01

    The goal of this review is to summarize the recent plethora of data that relate to long-term outcomes after acute kidney injury (AKI). Surviving patients with AKI are still at high risk for long-term adverse outcomes, even if serum creatinine returns to normal. After adjusting for potential confounders, many recent studies have demonstrated that AKI is independently associated with chronic kidney disease, end-stage renal disease, and premature death. Unfortunately, definitive evidence from randomized controlled trials demonstrating that prevention or treatment of AKI prevents long-term adverse outcomes is not yet available. AKI is clearly a prognostic marker for poor long-term outcomes, but more studies will be needed to determine whether AKI is truly causal and whether or not the risk is modifiable.

  8. Neurobiochemical changes in the vicinity of a nanostructured neural implant

    NASA Astrophysics Data System (ADS)

    Bérces, Zsófia; Tóth, Kinga; Márton, Gergely; Pál, Ildikó; Kováts-Megyesi, Bálint; Fekete, Zoltán; Ulbert, István; Pongrácz, Anita

    2016-10-01

    Neural interface technologies including recording and stimulation electrodes are currently in the early phase of clinical trials aiming to help patients with spinal cord injuries, degenerative disorders, strokes interrupting descending motor pathways, or limb amputations. Their lifetime is of key importance; however, it is limited by the foreign body response of the tissue causing the loss of neurons and a reactive astrogliosis around the implant surface. Improving the biocompatibility of implant surfaces, especially promoting neuronal attachment and regeneration is therefore essential. In our work, bioactive properties of implanted black polySi nanostructured surfaces (520-800 nm long nanopillars with a diameter of 150-200 nm) were investigated and compared to microstructured Si surfaces in eight-week-long in vivo experiments. Glial encapsulation and local neuronal cell loss were characterised using GFAP and NeuN immunostaining respectively, followed by systematic image analysis. Regarding the severity of gliosis, no significant difference was observed in the vicinity of the different implant surfaces, however, the number of surviving neurons close to the nanostructured surface was higher than that of the microstructured ones. Our results imply that the functionality of implanted microelectrodes covered by Si nanopillars may lead to improved long-term recordings.

  9. Long-term metapopulation study of the Glanville fritillary butterfly (Melitaea cinxia): survey methods, data management, and long-term population trends.

    PubMed

    Ojanen, Sami P; Nieminen, Marko; Meyke, Evgeniy; Pöyry, Juha; Hanski, Ilkka

    2013-10-01

    Long-term observational studies conducted at large (regional) spatial scales contribute to better understanding of landscape effects on population and evolutionary dynamics, including the conditions that affect long-term viability of species, but large-scale studies are expensive and logistically challenging to keep running for a long time. Here, we describe the long-term metapopulation study of the Glanville fritillary butterfly (Melitaea cinxia) that has been conducted since 1991 in a large network of 4000 habitat patches (dry meadows) within a study area of 50 by 70 km in the Åland Islands in Finland. We explain how the landscape structure has been described, including definition, delimitation, and mapping of the habitat patches; methods of field survey, including the logistics, cost, and reliability of the survey; and data management using the EarthCape biodiversity platform. We describe the long-term metapopulation dynamics of the Glanville fritillary based on the survey. There has been no long-term change in the overall size of the metapopulation, but the level of spatial synchrony and hence the amplitude of fluctuations in year-to-year metapopulation dynamics have increased over the years, possibly due to increasing frequency of exceptional weather conditions. We discuss the added value of large-scale and long-term population studies, but also emphasize the need to integrate more targeted experimental studies in the context of long-term observational studies. For instance, in the case of the Glanville fritillary project, the long-term study has produced an opportunity to sample individuals for experiments from local populations with a known demographic history. These studies have demonstrated striking differences in dispersal rate and other life-history traits of individuals from newly established local populations (the offspring of colonizers) versus individuals from old, established local populations. The long-term observational study has stimulated the

  10. Long-term metapopulation study of the Glanville fritillary butterfly (Melitaea cinxia): survey methods, data management, and long-term population trends

    PubMed Central

    Ojanen, Sami P; Nieminen, Marko; Meyke, Evgeniy; Pöyry, Juha; Hanski, Ilkka

    2013-01-01

    Long-term observational studies conducted at large (regional) spatial scales contribute to better understanding of landscape effects on population and evolutionary dynamics, including the conditions that affect long-term viability of species, but large-scale studies are expensive and logistically challenging to keep running for a long time. Here, we describe the long-term metapopulation study of the Glanville fritillary butterfly (Melitaea cinxia) that has been conducted since 1991 in a large network of 4000 habitat patches (dry meadows) within a study area of 50 by 70 km in the Åland Islands in Finland. We explain how the landscape structure has been described, including definition, delimitation, and mapping of the habitat patches; methods of field survey, including the logistics, cost, and reliability of the survey; and data management using the EarthCape biodiversity platform. We describe the long-term metapopulation dynamics of the Glanville fritillary based on the survey. There has been no long-term change in the overall size of the metapopulation, but the level of spatial synchrony and hence the amplitude of fluctuations in year-to-year metapopulation dynamics have increased over the years, possibly due to increasing frequency of exceptional weather conditions. We discuss the added value of large-scale and long-term population studies, but also emphasize the need to integrate more targeted experimental studies in the context of long-term observational studies. For instance, in the case of the Glanville fritillary project, the long-term study has produced an opportunity to sample individuals for experiments from local populations with a known demographic history. These studies have demonstrated striking differences in dispersal rate and other life-history traits of individuals from newly established local populations (the offspring of colonizers) versus individuals from old, established local populations. The long-term observational study has stimulated the

  11. Long-Term Dynamics of Autonomous Fractional Differential Equations

    NASA Astrophysics Data System (ADS)

    Liu, Tao; Xu, Wei; Xu, Yong; Han, Qun

    This paper aims to investigate long-term dynamic behaviors of autonomous fractional differential equations with effective numerical method. The long-term dynamic behaviors predict where systems are heading after long-term evolution. We make some modification and transplant cell mapping methods to autonomous fractional differential equations. The mapping time duration of cell mapping is enlarged to deal with the long memory effect. Three illustrative examples, i.e. fractional Lotka-Volterra equation, fractional van der Pol oscillator and fractional Duffing equation, are studied with our revised generalized cell mapping method. We obtain long-term dynamics, such as attractors, basins of attraction, and saddles. Compared with some existing stability and numerical results, the validity of our method is verified. Furthermore, we find that the fractional order has its effect on the long-term dynamics of autonomous fractional differential equations.

  12. The Womanly World of Long Term Care: The Plight of the Long Term Care Worker. Gray Paper.

    ERIC Educational Resources Information Center

    Older Women's League, Washington, DC.

    Long-term care workers (those who are paid to provide custodial care for long-term patients in nursing homes or at home) must care for a growing number of increasingly disabled or dependent persons. They are working for agencies and institutions under growing pressure to increase productivity. They face new training and competency requirements,…

  13. Long-term outcomes of anterior spinal fusion for treating thoracic adolescent idiopathic scoliosis curves: average 15-year follow-up analysis.

    PubMed

    Sudo, Hideki; Ito, Manabu; Kaneda, Kiyoshi; Shono, Yasuhiro; Takahata, Masahiko; Abumi, Kuniyoshi

    2013-05-01

    Retrospective review. To assess the long-term outcomes of anterior spinal fusion (ASF) for treating thoracic adolescent idiopathic scoliosis (AIS). Although ASF is reported to provide good coronal and sagittal correction of the main thoracic (MT) AIS curves, the long-term outcomes of ASF is unknown. A consecutive series of 25 patients with Lenke 1 MT AIS were included. Outcome measures comprised radiographical measurements, pulmonary function, and Scoliosis Research Society outcome instrument (SRS-30) scores (preoperative SRS-30 scores were not documented). Postoperative surgical revisions and complications were recorded. Twenty-five patients were followed-up for 12 to 18 years (average, 15.2 yr). The average MT Cobb angle correction rate and the correction loss at the final follow-up were 56.7% and 9.2°, respectively. The average preoperative instrumented level of kyphosis was 8.3°, which significantly improved to 18.6° (P = 0.0003) at the final follow-up. The average percent-predicted forced vital capacity and forced expiratory volume in 1 second were significantly decreased during long-term follow-up measurements (73% and 69%; P = 0.0004 and 0.0016, respectively). However, no patient had complaints related to pulmonary function. The average total SRS-30 score was 4.0. Implant breakage was not observed. All patients, except 1 who required revision surgery, demonstrated solid fusion. Late instrumentation-related bronchial problems were observed in 1 patient who required implant removal and bronchial tube repair, 13 years after the initial surgery. Overall radiographical findings and patient outcome measures of ASF for Lenke 1 MT AIS were satisfactory at an average follow-up of 15 years. ASF provides significant sagittal correction of the main thoracic curve with long-term maintenance of sagittal profiles. Percent-predicted values of forced vital capacity and forced expiratory volume in 1 second were decreased in this cohort; however, no patient had complaints

  14. Osteoporosis in patients on long-term home parenteral nutrition: a longitudinal study.

    PubMed

    Cohen-Solal, M; Baudoin, C; Joly, F; Vahedi, K; D'Aoust, L; De Vernejoul, M C; Messing, B

    2003-11-01

    The prevalence of osteoporosis was investigated in 88 patients with intestinal failure (IF). Osteoporosis was found in 67%, dependent of body mass index and age when IF occurred. In 56 patients on HPN, followed prospectively, changes in bone density were dependent on the duration of HPN; older patients had a higher increase. It has been suggested that low bone mass and negative bone balance may occur in adult patients receiving home parenteral nutrition (HPN). The aim of this study was to assess prospectively the prevalence of osteoporosis in intestinal failure (IF) patients and the changes in bone mineral density in those on long-term HPN and to analyze the factors that may influence the occurrence and evolution of osteoporosis. Bone mineral density was measured at the lumbar spine and femoral neck in 88 IF patients. At the first bone mineral density determination (baseline), the prevalence of osteoporosis was 67% in this population (median age, 52 years). Ten percent of the patients with osteoporosis experienced fragility fractures. Osteoporosis was independent of age and gender but occurred earlier in patients who had received corticosteroids. At baseline, the lumbar Z-score was positively correlated mainly to body mass index and age when IF occurred; these two parameters explained 34% of the Z-score. Repeated measurements were performed in 56 patients during long-term HPN (mean duration, 5.5 +/- 1.2 years). The changes in Z-score at the lumbar spine were dependent on the age when IF occurred and on the duration of HPN, with a synergistic effect between them. The older the patients, the higher the increase in Z-score during HPN. HPN had no deleterious effect on cortical bone and actually improved trabecular bone in patients whose intestinal disease started after the age of 21 years.

  15. Implant decontamination during surgical peri-implantitis treatment: a randomized, double-blind, placebo-controlled trial.

    PubMed

    de Waal, Yvonne C M; Raghoebar, Gerry M; Huddleston Slater, James J R; Meijer, Henny J A; Winkel, Edwin G; van Winkelhoff, Arie Jan

    2013-02-01

    The objective of this randomized, double-blind, placebo-controlled trial was to study the effect of implant surface decontamination with chlorhexidine (CHX)/cetylpyridinium chloride (CPC) on microbiological and clinical parameters. Thirty patients (79 implants) with peri-implantitis were treated with resective surgical treatment consisting of apically re-positioned flap, bone re-contouring and surface debridement and decontamination. Patients were randomly allocated to decontamination with 0.12% CHX + 0.05% CPC (test-group) or a placebo-solution (without CHX/CPC, placebo-group). Microbiological parameters were recorded during surgery; clinical and radiographical parameters were recorded before (pre-) treatment (baseline), and at 3, 6 and 12 months after treatment. Nine implants in two patients in the placebo-group were lost due to severe persisting peri-implantitis. Both decontamination procedures resulted in significant reductions of bacterial load on the implant surface, but the test-group showed a significantly greater reduction than the placebo-group (log 4.21 ± 1.89 versus log 2.77 ± 2.12, p = 0.006). Multilevel analysis showed no differences between both groups in the effect of the intervention on bleeding, suppuration, probing pocket depth and radiographical bone loss over time. Implant surface decontamination with 0.12% CHX + 0.05% CPC in resective surgical treatment of peri-implantitis leads to a greater immediate suppression of anaerobic bacteria on the implant surface than a placebo-solution, but does not lead to superior clinical results. The long-term microbiological effect remains unknown. © 2012 John Wiley & Sons A/S.

  16. Racial disparity in cardiac procedures and mortality among long-term survivors of cardiac arrest.

    PubMed

    Groeneveld, Peter W; Heidenreich, Paul A; Garber, Alan M

    2003-07-22

    It is unknown whether white and black Medicare beneficiaries have different rates of cardiac procedure utilization or long-term survival after cardiac arrest. A total of 5948 elderly Medicare beneficiaries (5429 white and 519 black) were identified who survived to hospital discharge between 1990 and 1999 after admission for cardiac arrest. Demographic, socioeconomic, and clinical information about these patients was obtained from Medicare administrative files, the US census, and the American Hospital Association's annual institutional survey. A Cox proportional hazard model that included demographic and clinical predictors indicated a hazard ratio for mortality of 1.30 (95% CI 1.09 to 1.55) for blacks aged 66 to 74 years compared with whites of the same age. The addition of cardiac procedures to this model lowered the hazard ratio for blacks to 1.23 (95% CI 1.03 to 1.46). In analyses stratified by race, implantable cardioverter-defibrillators (ICDs) had a mortality hazard ratio of 0.53 (95% CI 0.45 to 0.62) for white patients and 0.50 (95% CI 0.27 to 0.91) for black patients. Logistic regression models that compared procedure rates between races indicated odds ratios for blacks aged 66 to 74 years of 0.58 (95% CI 0.36 to 0.94) to receive an ICD and 0.50 (95% CI 0.34 to 0.75) to receive either revascularization or an ICD. There is racial disparity in long-term mortality among elderly cardiac arrest survivors. Both black and white patients benefited from ICD implantation, but blacks were less likely to undergo this potentially life-saving procedure. Lower rates of cardiac procedures may explain in part the lower survival rates among black patients.

  17. Long-term results from an epiretinal prosthesis to restore sight to the blind

    PubMed Central

    Ho, Allen C.; Humayun, Mark S.; Dorn, Jessy D.; da Cruz, Lyndon; Dagnelie, Gislin; Handa, James; Barale, Pierre-Olivier; Sahel, José-Alain; Stanga, Paulo E.; Hafezi, Farhad; Safran, Avinoam B.; Salzmann, Joel; Santos, Arturo; Birch, David; Spencer, Rand; Cideciyan, Artur V.; de Juan, Eugene; Duncan, Jacque L.; Eliott, Dean; Fawzi, Amani; Olmos de Koo, Lisa C.; Brown, Gary C.; Haller, Julia A.; Regillo, Carl D.; Del Priore, Lucian V.; Arditi, Aries; Geruschat, Duane R.; Greenberg, Robert J.

    2015-01-01

    Purpose Retinitis Pigmentosa (RP) is a group of inherited retinal degenerations leading to blindness due to photoreceptor loss. A rare disease, it affects about 100,000 people in the United States. There is no cure and no approved medical therapy to slow or reverse RP. The purpose of this clinical trial was to evaluate the safety, reliability, and benefit of the Argus® II Retinal Prosthesis System (Second Sight Medical Products, Inc., Sylmar, CA) in restoring some visual function to subjects completely blind from RP. Herein, we report clinical trial results at 1 and 3 years post-implant. Design The study is a multicenter, single-arm, prospective clinical trial. Subjects There were 30 subjects in 10 centers in the U.S. and Europe. Subjects served as their own controls – i.e., implanted eye vs. fellow eye, and System ON vs. System OFF (native residual vision). Methods The Argus II System was implanted on and in a single eye (typically the worse-seeing eye) of blind subjects. Subjects wore glasses mounted with a small camera and a video processor that converted images into stimulation patterns sent to the electrode array on the retina. Main Outcome Measures The primary outcome measures were safety (the number, seriousness, and relatedness of adverse events) and visual function, as measured by three computer-based, objective tests. Results Twenty-nine out of 30 subjects remained implanted with functioning Argus II Systems at 3 years post-implant. Eleven subjects experienced a total of 23 serious device- or surgery-related adverse events. All were treated with standard ophthalmic care. As a group, subjects performed significantly better with the System ON than OFF on all visual function tests and functional vision assessments. Conclusions The three-year results of the Argus II trial support the long-term safety profile and benefit of the Argus II System for patients blind from RP. Earlier results from this trial were used to gain approval of the Argus II by the FDA

  18. Long-term studies of dopamine agonists.

    PubMed

    Hubble, Jean P

    2002-02-26

    Dopamine agonists have long been used as adjunctive therapy for the treatment of Parkinson's disease (PD). In more recent years these drugs have also been proved safe and effective as initial therapy in lieu of levodopa in the treatment of PD. Long-term levodopa therapy is associated with motor complications, including fluctuating response patterns and dyskinesia. By initially introducing a dopamine agonist as symptomatic drug therapy, it may be possible to postpone the use of levodopa and delay or prevent the development of motor complications. Recently, four clinical trials have explored this hypothesis by comparing the long-term response and side effects of levodopa with dopamine agonist therapy. The drugs studied have included ropinirole, pramipexole, cabergoline, and pergolide. In each of these projects, the occurrence of motor complications, such as wearing off and dyskinesia, was significantly less in the subjects assigned to initiation of therapy with a dopamine agonist. The addition of levodopa could be postponed by many months or even several years. Therefore, these long-term studies of dopamine agonists support the initiation of a dopamine agonist instead of levodopa in an effort to postpone levodopa-related motor complications. This therapeutic approach may be particularly appropriate in PD patients with a long treatment horizon on the basis of age and general good health. The extension phase of the long-term study comparing pramipexole with levodopa is ongoing, and follow-up information may help to establish the value of this treatment strategy.

  19. Health, Maintenance, and Recovery of Soft Tissues around Implants.

    PubMed

    Wang, Yulan; Zhang, Yufeng; Miron, Richard J

    2016-06-01

    The health of peri-implant soft tissues is one of the most important aspects of osseointegration necessary for the long-term survival of dental implants. To review the process of soft tissue healing around osseointegrated implants and discuss the maintenance requirements as well as the possible short-comings of peri-implant soft tissue integration. Literature search on the process involved in osseointegration, soft tissue healing and currently available treatment modalities was performed and a brief description of each process was provided. The peri-implant interface has been shown to be less effective than natural teeth in resisting bacterial invasion because gingival fiber alignment and reduced vascular supply make it more vulnerable to subsequent peri-implant disease and future bone loss around implants. And we summarized common procedures which have been shown to be effective in preventing peri-implantitis disease progression as well as clinical techniques utilized to regenerate soft tissues with bone loss in advanced cases of peri-implantitis. Due to the difference between peri-implant interface and natural teeth, clinicians and patients should pay more attention in the maintenance and recovery of soft tissues around implants. © 2015 Wiley Periodicals, Inc.

  20. Critical review of immediate implant loading.

    PubMed

    Gapski, Ricardo; Wang, Hom-Lay; Mascarenhas, Paulo; Lang, Niklaus P

    2003-10-01

    Implant dentistry has become successful with the discovery of the biological properties of titanium. In the original protocol, studies have advocated a 2-stage surgical protocol for load-free and submerged healing to ensure predictable osseointegration. However, the discomfort, inconvenience, and anxiety associated with waiting period remains a challenge to both patients and clinicians. Hence, loading implant right after placement was attempted and has gained popularity among clinicians. Issues/questions related to this approach remain unanswered. Therefore, it is the purpose of this review article to (1). review and analyze critically the current available literature in the field of immediate implant loading and (2). discuss, based on scientific evidence, factors that may influence this treatment modality. Literature published over the past 20 years was selected and reviewed. Findings from these studies were discussed and summarized in the tables. The advantages and disadvantages associated with immediate implant loading were analyzed. Factors that may influence the success of immediate implant loading, including patient selection, type of bone quality, required implant length, micro- and macrostructure of the implant, surgical skill, need for achieving primary stability/control of occlusal force, and prosthesis guidelines, were thoroughly reviewed and discussed. Various studies have demonstrated the feasibility and predictability of this technique. However, most of these articles are based on retrospective data or uncontrolled cases. Randomized, prospective, parallel-armed longitudinal human trials are primarily based on short-term results and long-term follow-ups are still scarce in this field. Nonetheless, from available literature, it may be concluded that anatomic locations, implant designs, and restricted prosthetic guidelines are key to ensure successful outcomes. Future studies, preferably randomized, prospective longitudinal studies, are certainly needed