Science.gov

Sample records for intralesional insulated needles

  1. Ultrasonic findings of fetal axillary lymphangioma with intralesional hemorrhage.

    PubMed

    Furue, Akiko; Mochizuki, Junko; Onishi, Yoko; Kawano, Shoko; Kanai, Yuji; Kemmochi, Manabu; Tanaka, Kiyoshi; Unno, Nobuya

    2016-04-01

    We report a case of an axillary lymphangioma in a fetus delivered at 30 weeks' gestation with suspected intralesional hemorrhage based on the ultrasonic findings. In the ultrasonic examination at 15 weeks' gestation, the fetus was found to have a multilocular mass spreading from the axilla to the chest wall, which was diagnosed as an axillary lymphangioma. Chromosome analysis by amniocentesis showed a normal karyotype, and no other malformations were observed. At 29 weeks, the mass had increased in size, and color Doppler ultrasound examination revealed that the middle cerebral artery peak systolic velocity (MCA-PSV) reached 80.2 cm/s [1.86 MoM (multiples of the median)]. Intralesional bleeding was suspected because of the multiple images of hemorrhage in which sites of blood spouting in a pulsatile fashion were detected within the mass. Cordocentesis at 30 weeks revealed that fetal hemoglobin concentration was 5.1 g/dL. An emergency Cesarean section was performed. A female weighing 2810 g, including the mass, was delivered, and the blood hemoglobin level was 5.9 g/dL at birth. Blood transfusion, fine-needle aspiration of the fluid in the mass, intralesional injection of OK-432, and partial excision of the lymphangioma were performed after birth. Ultrasonic examination proved useful in the diagnosis of intralesional bleeding in this lymphangioma. PMID:26707998

  2. A technique for periorbital syringomas: intralesional radiofrequency ablation

    PubMed Central

    Huang, Li-Ping; Zhang, Leng; Wang, Xing-Lin; Liu, Xiao-Cui; Jiang, Tian-Yu; Lin, Bi-Weng

    2012-01-01

    AIM To evaluate the efficacy of intralesional radiofrequency ablation in the treatment of periorbital syringomas. METHODS We tried the intralesional radiofrequency ablation for 64 patients with periorbital syringomas from 2007 to 2011. The operation was performed under 2.5 loupe magnifications. The handpiece was assembled with a needle electrode and connected to the radiofrequency ablation apparatus. The electrode was then inserted into the target lesions in dermis and delivering injury to the base of these tumors. Results were assessed clinically by comparing pre- and post-treatment photographs and patient satisfaction rates. RESULTS Clinical improvement increased with each subsequent treatment session. The percent of patients whose clinic improvement grade were≥3 after each session was respectively 71.9%(Session1), 83.3%(Session2), and 100%(Session3). The statistical results indicated the concordance of the clinical assessment and the satisfaction level of patients (kappa=0.78 of the session1; kappa=0.82 of the session2). The majority of patients had good or excellent cosmetic results. Postoperatively, there were no permanent side effects or recurrences. CONCLUSION As a new technique of minimally invasion, the intralesional radiofrequency ablation was found to be an effective, inexpensive, highly precise and safe way of treating periorbital syringomas. PMID:22762046

  3. Arthroscope assisted intralesional curettage of GCT

    PubMed Central

    Kekatpure, Aashay; Pimprikar, Milind; Kekatpure, Aditya

    2015-01-01

    Introduction: Incomplete intralesional curettage remains the most important factor contributing to the recurrence of the GCT tumor. A 360 degree view of the tumor cavity can be achieved with the help of an arthroscope, which can aid complete intralesional curettage. Case Report: This technical note describes the use of arthroscope assisted curettage of the distal femur GCT. Conclusion: Use of an arthroscope can improve the visibility for intralesional curettage 5 of Giant Cell tumor. PMID:27299030

  4. Peyronie's Disease: Intralesional Therapy and Surgical Intervention.

    PubMed

    Aliperti, Louis A; Mehta, Akanksha

    2016-09-01

    Peyronie's disease is a collagen wound healing disorder of the penis that negatively affects the quality of life of afflicted men. According to the 2015 AUA Consensus Guidelines on Peyronie's Disease, minimally invasive intralesional therapies and surgical intervention form the basis of contemporary therapy for this disorder. These therapeutic options, along with selected portions of the guidelines, are explored in this review. PMID:27432377

  5. Intralesional Cidofovir application in recurrent laryngeal papillomatosis.

    PubMed

    Pudszuhn, Annett; Welzel, Cornelia; Bloching, Marc; Neumann, Kerstin

    2007-01-01

    Recurrent laryngeal papillomatosis is a benign disease of the larynx often leading to organic and functional restrictions. The therapeutic treatment of choice in larynx-obstructing papillomatosis is at present surgical laser ablation. The effectiveness of adjuvant intralesional injection of the virustaticum Cidofovir has been investigated recently in a variety of therapeutic models. The present case study deals with the treatment of recurrent laryngeal papillomatosis by means of surgical laser ablation of the laryngeal papillomas with adjuvant local injection of the virustaticum Cidofovir (dose of 5 mg/1 ml). Within the period from October 2001 to August 2004, ten patients aged between 5- and 70 years were treated with intralesional injections of Cidofovir. Papillomatosis was confirmed histologically in all cases, and the virus types were defined in part. Each of the patients underwent clinical-phoniatric examinations and was photographed for documentation. After 2-7 treatments with surgical laser papilloma ablation and intralesional Cidofovir injections, all patients showed a definite papilloma reduction, while in six cases complete remission was achieved. During the follow-up period of 8-30 months, not a single recurrence of the laryngeal papillomatosis occurred. In the majority of patients, a clear improvement in the voice was achieved. There were no local or systemic side effects caused by the virustaticum. Intralesional injection of Cidofovir is an adjuvant, but not a curative therapeutic option in recurrent laryngeal papillomatosis. Remission of previously frequently recurrent laryngeal papillomas can be achieved, but recurrence after longer treatment-free intervals is also possible. PMID:17058091

  6. Insulation.

    ERIC Educational Resources Information Center

    Rhea, Dennis

    This instructional unit is one of 10 developed by students on various energy-related areas that deals specifically with insulation. Its objective is for the student to be able to determine insulation needs of new or existing structures, select type to use, use installation techniques, calculate costs, and apply safety factors. Some topics covered…

  7. The Role of Intralesional Therapies in Melanoma.

    PubMed

    Agarwala, Sanjiv S

    2016-05-01

    The US Food and Drug Administration has been rapidly approving new checkpoint inhibitors and targeted therapies for melanoma and other tumors. Recently, it approved the first intralesional therapy, talimogene laherparepvec (T-VEC), for the treatment of metastatic melanoma lesions in the skin and lymph nodes. Several other intralesional therapies (PV-10, interleukin-12 electroporation, coxsackievirus A21 [CVA21]) are entering later-stage testing. Locally injected agents have clearly shown their ability to produce local responses that can be durable. The possibility that they also stimulate a regional and even systemic immune response is exciting, as this potential effect may have utility in combination regimens; such regimens are an area of active research. Favorable responses with minimal toxicities in monotherapy trials have led to the first melanoma studies of T-VEC in combination with the cytotoxic T-lymphocyte-associated antigen 4 inhibitor ipilimumab and, separately, with the programmed death 1-blocking antibody pembrolizumab. Studies of PV-10 with pembrolizumab and of CVA21 with pembrolizumab are also being initiated. Preliminary analyses of the results of the first combination trials, which show higher response rates than with either agent alone, offer some optimism that these locoregional therapies will find application--as treatment for patients who cannot tolerate systemic immunotherapies, to alleviate locoregional morbidity, and perhaps even to "prime" the immune system. PMID:27188674

  8. Ocular Leishmaniasis Treated by Intralesional Amphotericin B

    PubMed Central

    Nikandish, Malihe; Goyonlo, Vahid Mashayekhi; Taheri, Ahmad Reza; Kiafar, Bita

    2016-01-01

    Leishmaniasis is a group of diseases with varied clinical manifestations. Ocular involvement is an unusual presentation of leishmaniasis, and the eyelid is not a common site of cutaneous lesions, likely due to the mobility of the lids. Some case reports of conjunctival involvement are either a contiguous dissemination from lid margin or in the setting of disseminated leishmaniasis in an immunocompromised host. To our knowledge, isolated involvement of the bulbar conjunctiva has not been reported. We present the first case in the literature of a patient with an erythematous fibrovascular lesion in the interpalpebral zone that was clinically diagnosed as pterygium, but recurred at the site of surgical excision. After histopathologic diagnosis, the lesion was treated with intralesional injection of amphotericin B and improved completely within a few weeks. An accurate diagnosis of leishmaniasis in the eye may be challenging in many clinical settings. To our knowledge, an isolated pterygium.like lesion has not been reported in literature. In addition, intralesional injection of amphotericin B is a novel treatment method in this setting. PMID:26957858

  9. Pre-tibial myxedema: treatment with intralesional corticosteroid*

    PubMed Central

    Ramos, Luana Oliveira; Mattos, Paloma Corrêa; de Figueredo, Giuseppe Lemos Pertoti; Maia, Alef Alioscha Andrade; Romero, Sandra Adolfina Reys

    2015-01-01

    The pretibial myxedema is a manifestation of Graves' disease characterized by accumulation of glycosaminoglycans in the reticular dermis. The dermopathy is self-limiting but in some cases may cause cosmetic and functional damage. Conventional treatment is use of topical steroids under occlusive dressing, however the intralesional application has shown good results. We present a case of pretibial myxedema treated with single injection of intralesional corticosteroid. PMID:26312698

  10. Pre-tibial myxedema: treatment with intralesional corticosteroid.

    PubMed

    Ramos, Luana Oliveira; Mattos, Paloma Corrêa; Figueredo, Giuseppe Lemos Pertoti de; Maia, Alef Alioscha Andrade; Romero, Sandra Adolfina Reys

    2015-01-01

    The pretibial myxedema is a manifestation of Graves' disease characterized by accumulation of glycosaminoglycans in the reticular dermis. The dermopathy is self-limiting but in some cases may cause cosmetic and functional damage. Conventional treatment is use of topical steroids under occlusive dressing, however the intralesional application has shown good results. We present a case of pretibial myxedema treated with single injection of intralesional corticosteroid. PMID:26312698

  11. Intralesional Bleomycin as an Adjunct Therapeutic Modality in Eyelid and Extraocular Malignancies and Tumors

    PubMed Central

    Meyer, David; Gooding, Caroline

    2015-01-01

    To present our recent experience with intralesional bleomycin (IBI) in nonmelanoma extraocular tumors, and present previous experience on periocular capillary hemangiomas and orbital lymphangiomas in a tertiary referral hospital. This was a retrospective descriptive study of patients with eyelid and extraocular malignancies where conventional therapies failed, or surgery was contraindicated or refused and were offered IBI as an alternate therapy. All patients were recruited from the Oculoplastics Clinic at Tygerberg Academic Hospital, Cape Town, South Africa. A solution containing 1 international unit of bleomycin per milliliter saline was injected intralesionally together with 2% lignocaine in a ratio of 4:1. The injected volume was calculated to be equivalent to the estimated volume of the lesion. A multipuncture technique with a 29-gauge needle was used. Patients requiring retreatment were injected every 4–8 weeks until satisfactory clinical endpoints were achieved. Our previous experience with IBI in extensive capillary hemangiomas and orbital lymphangiomas is reviewed. Cases are presented to illustrate that IBI induced significant regression and reduction in tumor size and marked clinical improvement of the eyelid and orbital basal cell carcinomas, Kaposi sarcoma, and mycosis fungoides. The improvements obviated the need for further surgical intervention in most cases. Based on clinical experience we propose that IBI should be considered a treatment modality in select cases of the malignant eyelid and ophthalmic vascular tumors where the conventional standard of care is not possible. IBI is a reasonable alternative or adjunct to consider in such cases. PMID:26692709

  12. Treatment of laryngeal sarcoidosis with intralesional steroid injection.

    PubMed

    Krespi, Y P; Mitrani, M; Husain, S; Meltzer, C J

    1987-01-01

    Laryngeal sarcoidosis presents with hoarseness, cough, and dysphagia. Shortness of breath due to upper airway obstruction may occur. Indirect laryngoscopy reveals mucosal edema and erythema, granulomas, and nodules. The supraglottic larynx is the most frequently affected area. Systemic corticosteroids can be used initially; however, with persistent symptoms and/or severe airway problems, intralesional steroid injections may be more effective, as in the six patients presented. PMID:3688765

  13. Effect of intralesional 5 fluorouracil injection in primary pterygium

    PubMed Central

    Khan, Muhammad Saim; Malik, Sidra; Basit, Imran

    2016-01-01

    Objective: To determine mean change in visual acuity, corneal astigmatism and clinical appearance of pterygium after intralesional injection of 5-Fluorouracil. Methods: This was a Quasi experimental study conducted at Armed Forces Institute of Ophthalmology, Rawalpindi, Pakistan from June 2014 to May 2015. Total 68 eyes of 54 patients were included in the study. Patients were treated by injecting 0.1 ml of 5-FU (5mg) weekly injections for 04 weeks. All the patients underwent ophthalmic clinical examination that included Uncorrected distant visual acuity (UCVA), corrected distant visual acuity (CDVA), keratometery with Auto Ref-keratometer (RK-F1, Canon) and slit lamp examination before and 04 weeks after the last injection. Results: Total 68 eyes of 54 patients (18 females and 36 males) were treated with intralesional injection of 5 FU. Out of total, 30 were right eyes while 38 were left eyes. Age of patients ranged from 23 to 53 years with mean age of 39.2 ± 4.90 years. Mean UCVA and corneal astigmatism before treatment were 0.162 ± 0.167 and 2.12 ± 1.53 respectively while the same parameters 04 weeks after last injection of 5 FU were 0.166 ± 0.168 and 1.92±1.45 respectively. The magnitude of induced change in astigmatism was (0.235 ± 1.35). Ninety seven percent of the patients showed improvement in clinical appearance. Conclusion: Intralesional 5-FU injection results in significant clinical and cosmetic improvement of primary pterygium. PMID:27022360

  14. Recent Developments in the Use of Intralesional Injections Keloid Treatment

    PubMed Central

    Trisliana Perdanasari, Aurelia; Lazzeri, Davide; Su, Weijie; Xi, Wenjing; Zheng, Zhang; Ke, Li; Min, Peiru; Feng, Shaoqing; Persichetti, Paolo

    2014-01-01

    Keloid scars are often considered aesthetically unattractive and frustrating problems that occur following injuries. They cause functional and cosmetic deformities, displeasure, itching, pain, and psychological stress and possibly affect joint movement. The combination of these factors ultimately results in a compromised quality of life and diminished functional performance. Various methods have been implemented to improve keloid scars using both surgical and non-surgical approaches. However, it has proven to be a challenge to identify a universal treatment that can deliver optimal results for all types of scars. Through a PubMed search, we explored most of the literature that is available about the intralesional injection treatment of hypertrophic scars and keloids and highlights both current (corticosteroid, 5-fluorouracil, bleomycin, interferon, cryotherapy and verapamil) and future treatments (interleukin-10 and botulinum toxin type A). The reference lists of retrieved articles were also analysed. Information was gathered about the mechanism of each injection treatment, its benefits and associated adverse reactions, and possible strategies to address adverse reactions to provide reliable guidelines for determining the optimal treatment for particular types of keloid scars. This article will benefit practitioners by outlining evidence-based treatment strategies using intralesional injections for patients with hypertrophic scars and keloids. PMID:25396172

  15. Recent developments in the use of intralesional injections keloid treatment.

    PubMed

    Trisliana Perdanasari, Aurelia; Lazzeri, Davide; Su, Weijie; Xi, Wenjing; Zheng, Zhang; Ke, Li; Min, Peiru; Feng, Shaoqing; Zhang, Yi Xin; Persichetti, Paolo

    2014-11-01

    Keloid scars are often considered aesthetically unattractive and frustrating problems that occur following injuries. They cause functional and cosmetic deformities, displeasure, itching, pain, and psychological stress and possibly affect joint movement. The combination of these factors ultimately results in a compromised quality of life and diminished functional performance. Various methods have been implemented to improve keloid scars using both surgical and non-surgical approaches. However, it has proven to be a challenge to identify a universal treatment that can deliver optimal results for all types of scars. Through a PubMed search, we explored most of the literature that is available about the intralesional injection treatment of hypertrophic scars and keloids and highlights both current (corticosteroid, 5-fluorouracil, bleomycin, interferon, cryotherapy and verapamil) and future treatments (interleukin-10 and botulinum toxin type A). The reference lists of retrieved articles were also analysed. Information was gathered about the mechanism of each injection treatment, its benefits and associated adverse reactions, and possible strategies to address adverse reactions to provide reliable guidelines for determining the optimal treatment for particular types of keloid scars. This article will benefit practitioners by outlining evidence-based treatment strategies using intralesional injections for patients with hypertrophic scars and keloids. PMID:25396172

  16. Finite element model of needle electrode sensitivity

    NASA Astrophysics Data System (ADS)

    Høyum, P.; Kalvøy, H.; Martinsen, Ø. G.; Grimnes, S.

    2010-04-01

    We used the Finite Element (FE) Method to estimate the sensitivity of a needle electrode for bioimpedance measurement. This current conducting needle with insulated shaft was inserted in a saline solution and current was measured at the neutral electrode. FE model resistance and reactance were calculated and successfully compared with measurements on a laboratory model. The sensitivity field was described graphically based on these FE simulations.

  17. Needle Phobia.

    PubMed

    Cook, Lynda S

    2016-01-01

    Venipuncture is generally associated with some degree of pain, discomfort, and/or apprehension. Yet most patients accept it with tolerance, even nonchalance. A few, not only pediatric patients, exhibit a higher degree of anxiety and face the procedure with tears, tension, and a variety of bargaining techniques (ie, stick on the count of 3; use only this vein). But for 1 group of people, venipuncture is associated with such fear that avoidance of the procedure is practiced. The end results are detrimental to the patient and may have an impact on society as well. These are patients the American Psychiatric Association classifies as needle phobic. What can a nurse with no training in psychiatry do to assist these patients? To form an appropriate professional response, it's beneficial for practitioners to recognize the different pathways that lead to needle phobia and the issues related to the disorder. PMID:27598066

  18. Intralesional vinblastine injections for treatment of classic Kaposi sarcoma in diabetic patients.

    PubMed

    Vassallo, Camilla; Carugno, Andrea; Derlino, Federica; Ciocca, Olga; Brazzelli, Valeria; Borroni, Giovanni

    2015-05-01

    Classic Kaposi sarcoma (KS) usually is a localized and slowly progressing disease that mainly affects elderly patients; therefore, local treatment generally is recommended. In this study, we evaluated the clinical efficacy of intralesional vinblastine (VNB) for the treatment of classic KS in 6 participants with type 2 diabetes mellitus. Results indicated that intralesional VNB injections may be an effective alternative treatment of classic KS in diabetic patients. PMID:26057517

  19. Evaluation of intralesional 0.2% ciprofloxacin as a treatment for cutaneous leishmaniasis.

    PubMed

    Al Hamdi, K; Awad, A H; Moker, H M

    2010-01-01

    Although cutaneous leishmaniasis lesions usually heal spontaneously they cause unsightly scarring. This study evaluated a possible new therapy in 38 patients, with 70 lesions, randomly assigned to intralesional injection of ciprofloxacin (0.2%) or intralesional sodium chloride hypertonic solution (7%). After excluding patients who defaulted on treatment, lesions assigned to sodium chloride treatment (n = 21) were completely healed (with or without scarring) in 76.2% of cases, and, when a scar remained, the scar size was reduced 66.0% compared with the original lesion. Lesions assigned to ciprofloxacin (n = 27) showed an 81.5% healing rate with an average scar size reduction of 68.6%. Intralesional 0.2% ciprofloxacin was as effective as hypertonic saline in the treatment of cutaneous leishmaniasis infection. PMID:20214164

  20. Thermal insulation protection means

    NASA Technical Reports Server (NTRS)

    Dotts, R. L.; Smith, J. A.; Strouhal, G. (Inventor)

    1979-01-01

    A system for providing thermal insulation for portions of a spacecraft which do not exceed 900 F during ascent or reentry relative to the earth's atmosphere is described. The thermal insulation is formed of relatively large flexible sheets of needled Nomex felt having a flexible waterproof coating. The thickness of the felt is sized to protect against projected temperatures and is attached to the structure by a resin adhesive. Vent holes in the sheets allow ventilation while maintaining waterproofing. The system is heat treated to provide thermal stability.

  1. [Intrapulmonary Sewing Needle].

    PubMed

    Hisama, Naoya; Tsunemitsu, Nobumasa; Yasumasu, Tetsuo; Yamasaki, Takashi; Uchida, Takahisa

    2016-06-01

    Intrapulmonary aberrant needles are rarely encountered in clinical practice. A 82-year-old woman, though she was asymptomatic, was referred to our department due to an abnormal shadow on a chest X-ray. Chest X-ray and chest computed tomography showed a foreign body suspected to be a sewing needle in the left upper lobe. The needle was successfully removed by video-assisted thoracoscopic surgery. PMID:27246130

  2. Intralesional meglumine antimoniate for the treatment of localised cutaneous leishmaniasis: a retrospective review of a Brazilian referral centre

    PubMed Central

    da Silva, Rosiana Estéfane; Toledo, Antonio; Senna, Maria Camilo; Rabello, Ana; Cota, Gláucia

    2016-01-01

    Although intralesional meglumine antimoniate (MA) infiltration is considered an option for cutaneous leishmaniasis (CL) therapy and is widely used in the Old World, there have been few studies supporting this therapeutic approach in the Americas. This study aims to describe outcomes and adverse events associated with intralesional therapy for CL. This retrospective study reviewed the experience of a Brazilian leishmaniasis reference centre using intralesional MA to treat 31 patients over five years (2008 and 2013). The median age was 63 years (22-86) and the median duration time of the lesions up to treatment was 16 weeks. In 22 patients (71%), intralesional therapy was indicated due to the presence of contraindications or previous serious adverse events with systemic MA. Other indications were failure of systemic therapy or ease of administration. Intralesional treatment consisted of one-six infiltrations (median three) for a period of up to 12 weeks. The initial (three months) and definitive (six months) cure rates were 70.9% and 67.7%, respectively. Most patients reported mild discomfort during infiltration and no serious adverse events were observed. In conclusion, these results show that the intralesional MA efficacy rate was very similar to that of systemic MA treatment, and reinforce the need for further studies with adequate design to establish the efficacy and safety of this therapeutic approach. PMID:27508321

  3. Precessing Ferromagnetic Needle Magnetometer.

    PubMed

    Jackson Kimball, Derek F; Sushkov, Alexander O; Budker, Dmitry

    2016-05-13

    A ferromagnetic needle is predicted to precess about the magnetic field axis at a Larmor frequency Ω under conditions where its intrinsic spin dominates over its rotational angular momentum, Nℏ≫IΩ (I is the moment of inertia of the needle about the precession axis and N is the number of polarized spins in the needle). In this regime the needle behaves as a gyroscope with spin Nℏ maintained along the easy axis of the needle by the crystalline and shape anisotropy. A precessing ferromagnetic needle is a correlated system of N spins which can be used to measure magnetic fields for long times. In principle, by taking advantage of rapid averaging of quantum uncertainty, the sensitivity of a precessing needle magnetometer can far surpass that of magnetometers based on spin precession of atoms in the gas phase. Under conditions where noise from coupling to the environment is subdominant, the scaling with measurement time t of the quantum- and detection-limited magnetometric sensitivity is t^{-3/2}. The phenomenon of ferromagnetic needle precession may be of particular interest for precision measurements testing fundamental physics. PMID:27232012

  4. Precessing Ferromagnetic Needle Magnetometer

    NASA Astrophysics Data System (ADS)

    Jackson Kimball, Derek F.; Sushkov, Alexander O.; Budker, Dmitry

    2016-05-01

    A ferromagnetic needle is predicted to precess about the magnetic field axis at a Larmor frequency Ω under conditions where its intrinsic spin dominates over its rotational angular momentum, N ℏ≫I Ω (I is the moment of inertia of the needle about the precession axis and N is the number of polarized spins in the needle). In this regime the needle behaves as a gyroscope with spin N ℏ maintained along the easy axis of the needle by the crystalline and shape anisotropy. A precessing ferromagnetic needle is a correlated system of N spins which can be used to measure magnetic fields for long times. In principle, by taking advantage of rapid averaging of quantum uncertainty, the sensitivity of a precessing needle magnetometer can far surpass that of magnetometers based on spin precession of atoms in the gas phase. Under conditions where noise from coupling to the environment is subdominant, the scaling with measurement time t of the quantum- and detection-limited magnetometric sensitivity is t-3 /2. The phenomenon of ferromagnetic needle precession may be of particular interest for precision measurements testing fundamental physics.

  5. [Atraumatic needles for cataract surgery].

    PubMed

    Harnisch, J P

    1985-12-01

    The author reports on his experience with spatula needles and cutting needles with micropoint in cataract surgery. Configuration and edge treatment of the different needles were demonstrated by scanning electron microscope. The characteristics of the tested needles seem to depend mainly upon their profile. In cataract surgery the spatula needles proved to be superior to the needles with cutting micropoint due to their ski-shaped design. PMID:3912601

  6. Efficacy of intralesional immunotherapy for the treatment of warts: A review of the literature.

    PubMed

    Aldahan, Adam Souhail; Mlacker, Stephanie; Shah, Vidhi V; Kamath, Preetha; Alsaidan, Mohammed; Samarkandy, Sahal; Nouri, Keyvan

    2016-05-01

    Warts are common epidermal growths caused by human papillomavirus that often cause significant discomfort and embarrassment. Current treatment options include topical therapies, cryotherapy, laser vaporization, and surgical excision. Many of these options are destructive and may result in scarring, while less aggressive approaches can lead to lesion recurrence. Additionally, these local modalities are not practical for patients with a large number of warts. Systemic approaches such as immunotherapy have demonstrated success in treating multiple lesions by combining a targeted approach with upregulation of the host immune system. An extensive literature review was performed to evaluate the various vaccine antigens that have been used intralesionally to treat cutaneous and anogenital warts. The specific intralesional immunotherapies that have been studied include: Candida albicans; measles, mumps, and rubella; Trichophyton; and tuberculin antigens such as purified protein derivative, Mycobacterium w vaccine, and Bacillus Calmette-Guerin. Intralesional vaccine injection represents a safe, effective, and tolerable treatment for warts, including recalcitrant and anogenital warts. This approach has been somewhat overlooked in the past despite substantial evidence of high response rates with a low side effect profile. Large comparative trials are necessary to determine the most effective immunotherapy treatment option as well as the most appropriate dosing parameters. PMID:26991521

  7. Intralesional bleomycin injection in management of low flow vascular malformations in children.

    PubMed

    Mohan, Anita T; Adams, Saleigh; Adams, Kevin; Hudson, Donald A

    2015-04-01

    Low flow vascular malformations are challenging to manage, particularly with their propensity to grow, and can lead to severe disfigurement and dysfunction. Traditional surgical excision is fraught with tedious dissection and complications, particularly in the head and neck region. Trends toward less invasive techniques, such as intralesional sclerotherapy, are proving to be successful independent treatments or adjuncts in management in low flow vascular malformations. This study was a retrospective case note review, over an 8-year period, reporting the outcomes of 32 children (mean = 5.8 years, range = 5 months-11.5 years) with radiologically confirmed low flow vascular malformations, treated with serial intralesional bleomycin injection (IBI) therapy. Patient demographics, lesion characteristics, imaging findings, treatment course, radiological and clinical response to treatment were recorded. An overall 91% (n = 29) response rate was achieved, with 28% obtaining complete resolution for low flow vascular malformations. Lesions were sub-categorized into venous malformation, including mixed venous-capillary (n = 27) or lymphatic malformation (LM) (n = 5). Twenty-seven of 32 children experienced no complications. Local complications included superficial skin infection (n = 2), skin necrosis (n = 1), hyperpigmentation, and minor contour deformity. There was no recurrence and no systemic side-effects to bleomycin. Mean follow-up was 38 months (range = 6-95 months). In conclusion, serial intralesional bleomycin injections can be effective and also safe in a paediatric population for the successful management of symptomatic or disfiguring low flow vascular malformations. PMID:25204206

  8. Benign Post-Radiation Rectal Stricture Treated with Endoscopic Balloon Dilation and Intralesional Triamcinolone Injection

    PubMed Central

    Karanikas, Michael; Touzopoulos, Panagiotis; Mitrakas, Alexandros; Zezos, Petros; Zarogoulidis, Paul; Machairiotis, Nikolaos; Efremidou, Eleni; Liratzopoulos, Nikolaos; Polychronidis, Alexandros; Kouklakis, George

    2012-01-01

    Post-radiation stricture is a rare complication after pelvis irradiation, but must be in the mind of the clinician evaluating a lower gastrointestinal obstruction. Endoscopy has gained an important role in chronic radiation proctitis with several therapeutic options for management of intestinal strictures. The treatment of rectal strictures has been limited to surgery with high morbidity and mortality. Therefore, a less invasive therapeutic approach for benign rectal strictures, endoscopic balloon dilation with or without intralesional steroid injection, has become a common treatment modality. We present a case of benign post-radiation rectal stricture treated successfully with balloon dilation and adjuvant intralesional triamcinolone injection. A 70-year-old woman presented to the emergency room complaining for 2 weeks of diarrhea and meteorism, 11 years after radiation of the pelvis due to adenocarcinoma of the uterus. Colonoscopy revealed a stricture at the rectum and multiple endoscopic biopsies were obtained from the stricture. The stricture was treated with endoscopic balloon dilation and intralesional triamcinolone injection. The procedure appears to have a high success rate and a very low complication rate. Histologic examination of the biopsies revealed non-specific inflammatory changes of the rectal mucosa and no specific changes of the mucosa due to radiation. All biopsies were negative for malignancy. The patient is stricture-free 12 months post-treatment. PMID:23271987

  9. Comparison between intralesional injection of zinc sulfate 2 % solution and intralesional meglumine antimoniate in the treatment of acute old world dry type cutaneous leishmaniasis: a randomized double-blind clinical trial.

    PubMed

    Farajzadeh, Saeedeh; Hakimi Parizi, Maryam; Haghdoost, Ali Akbar; Mohebbi, Azadeh; Mohammadi, Saman; Pardakhty, Abbas; Eybpoosh, Sana; Heshmatkhah, Amireh; Vares, Behrooz; Saryazdi, Simin; Fekri, Ali Reza; Mohebbi, Elham

    2016-09-01

    Zinc sulfate (ZS) has been used for the treatment of acute cutaneous leishmaniasis (CL) in both forms of in vivo and in vitro recently. The aim of the present study was to compare the efficacy of intralesional injection of ZS 2 % solution with intralesional glucantime in the treatment of acute CL. In this double-blind randomized clinical trial, 80 cases with acute old world dry type CL were enrolled in the study. The treatment protocol in the first group consisted of intralesional injection of ZS 2 % vials once a week for 10 weeks or sooner in case of complete resolution of the lesions. In the second group, intralesional glucantime once a week for 10 weeks or sooner in case of complete resolution of the lesions were used. In both groups cryotherapy was performed once every other week for 10 weeks. In ZS versus second group, partial and complete clinical response was observed with fewer injections although this difference was not statistically significant. In addition, we found that the trend of treatment in second group was faster but again it was not significant [partial treatment: hazard ratio (HR) 1.4, 95 % CI 0.7-2.9; complete treatment: HR 1.3, 95 % CI 0.6-2.8]. The results of this study showed that the intralesional injection of ZS 2 % solution was as effective as glucantime on the healing of the acute old world dry type CL. PMID:27605813

  10. Thermoelectric needle probe for temperature measurements in biological materials.

    PubMed

    Korn, U; Rav-Noy, Z; Shtrikman, S; Zafrir, M

    1980-04-01

    In certain biological and medical applications it is important to measure and follow temperature changes inside a body or tissue. Any probe inserted into a tissue causes damage to tissue and distortion to the initial temperature distribution. To minimize this interference, a fine probe is needed. Thus, thin film technology is advantageous and was utilized by us to produce sensitive probes for these applications. The resulting probe is a small thermocouple at the tip of a thin needle (acupuncture stainless steel needle, approximately 0.26 mm in diameter and length in the range 5-10 cm was used). The junction was produced at the needle's tip by coating the needle with thin layers of insulating and thermoelectric materials. The first layer is an insulating one and is composed of polyacrylonitrile (PAN) and polymide produced by plasma polymerization and dip-coating respectively. This layer covers all the needle except the tip. The second layer is a vacuum deposited thermoelectric thin layer of Bi-5% Sb alloy coating also the tip. The third layer is for insulation and protection and is composed of PAN and polyimide. In this arrangement the junction is at the needle's tip, the needle is one conductor, the thermoelectric layer is the other and they are isolated by the plastic layer. The probe is handy and mechanically sturdy. The sensitivity is typically 77 microV/degrees C at room temperature and is constant to within 2% up to 90 degrees C. The response is fast (less than 1 sec) the noise is small, (less than 0.05 degrees C) and because of the small dimension, damage to tissue and disturbance to the measured temperature field are minimal. PMID:7382928

  11. Monopolar needle electrode spatial recording characteristics.

    PubMed

    King, J C; Dumitru, D; Stegeman, D

    1996-10-01

    The recording characteristics of the monopolar needle in three dimensions have not been well established. A simple spherical recording territory is commonly assumed with the very tip proposed to have a greater spatial recording sensitivity by some authors. We demonstrate by enlarged physical modeling in a homogeneous volume conductor that the recorded amplitude diminishes more gradually radially away from the conical surface than distally past the tip or proximal to the insulation edge. The sensitivity over the exposed metallic surface is found to be uniformly proportional to the area, which results in relatively less sensitivity at the tip than the middle and proximal portions of the conical recording surface. The overall spatial amplitude recording characteristics can be better described by an apple shape than a sphere, centered at the midportion of the exposed conical surface. A better appreciation of the actual spatial recording characteristics of the monopolar needle electrode can result in more accurate physiologic interpretations of quantitative motor unit analysis. PMID:8808657

  12. Pleural needle biopsy

    MedlinePlus

    ... et al, eds. Murray and Nadel's Textbook of Respiratory Medicine . 6th ed. Philadelphia, PA: Elsevier Saunders; 2016:chap 19. Ly A. Fine-needle aspiration biopsy technique and specimen ... Respiratory system. In: Watson N. Chapman and Nakielny's Guide ...

  13. Intracerebral sewing needle.

    PubMed

    Yolas, C; Aydin, M D; Ozdikici, M; Aydin, N; Onder, A

    2007-01-01

    A 9-year-old male patient complaining of seizure attack was admitted to the neurosurgery department. Radiologic investigations revealed a 5-cm-long metallic sewing needle extending from the right frontal cortex to the right lateral ventricle. Burr hole surgery was performed and the needle was grasped with biopsy forceps and removed with endoscopic guidance. The patient recovered without any complications. PMID:17786012

  14. Insulated Honeycomb

    NASA Technical Reports Server (NTRS)

    Bhat, Balakrishna T.

    1989-01-01

    Proposed insulated honeycomb structure similar to reinforced honeycomb structure described in NPO-17538. Panels of insulated honeycomb used to make supports for solar-energy collectors and radar antennas.

  15. Hot wire needle probe for thermal conductivity detection

    SciTech Connect

    Condie, Keith Glenn; Rempe, Joy Lynn; Knudson, Darrell lee; Daw, Joshua Earl; Wilkins, Steven Curtis; Fox, Brandon S.; Heng, Ban

    2015-11-10

    An apparatus comprising a needle probe comprising a sheath, a heating element, a temperature sensor, and electrical insulation that allows thermal conductivity to be measured in extreme environments, such as in high-temperature irradiation testing. The heating element is contained within the sheath and is electrically conductive. In an embodiment, the heating element is a wire capable of being joule heated when an electrical current is applied. The temperature sensor is contained within the sheath, electrically insulated from the heating element and the sheath. The electrical insulation electrically insulates the sheath, heating element and temperature sensor. The electrical insulation fills the sheath having electrical resistance capable of preventing electrical conduction between the sheath, heating element, and temperature sensor. The control system is connected to the heating element and the temperature sensor.

  16. Intra-lesional 5 fluorouracil for the management of recurrent pterygium

    PubMed Central

    Said, D G; Faraj, L A; Elalfy, M S; Yeung, A; Miri, A; Fares, U; Otri, A M; Rahman, I; Maharajan, S; Dua, H S

    2013-01-01

    Aim Recurrence is the most common complication arising from pterygium surgery. The aim of this study was to investigate the effectiveness of 5 fluorouracil (5FU) in halting the recurrence of pterygium after surgical excision. Methods A retrospective review of patients treated for pterygium recurrence was carried out. Patients with recurrent (secondary) pterygium were treated with multiple weekly intra-lesional injections of 0.1–0.2 ml (2.5–5 mg) 5FU post-operatively depending on the size of the recurrence. The treatment was started within 1 month from the date of recurrence. The time from surgery to start of recurrence, previous treatment modalities, and number of recurrences were documented. The number of injections required to induce arrest of progression and/or regression of vascularity and fleshiness of the pterygium and any complications related to 5FU treatment were examined. Results Fifteen eyes from 14 patients with recurrent pterygium treated with intra-lesional 5FU injections were analysed. Three of the 15 eyes had undergone a secondary excision and 12 had undergone a primary excision. In all, 93.3% of patients showed regression of the fibrovascular tissue (thickness and vascularity) and arrest of progression following a dose of 0.1–0.2 ml (2.5–5 mg) 5FU. Twelve eyes required three injections or fewer, whereas one patient required eight injections. This beneficial effect was maintained over an average follow-up period of 17 months. No complications from 5FU were observed. Conclusion The use of weekly intra-lesional 5FU injections for the treatment of recurrent pterygium is safe and effective in limiting the progression and inducing the regression of recurrent pterygium. The number of injections can be tailored according to clinical need. PMID:23807385

  17. Sodium Tetradecyl Sulphate Direct Intralesional Sclerotherapy of Venous Malformations of the Vulva and Vagina: Report of Five Cases

    SciTech Connect

    Krokidis, Miltiadis; Venetucci, Pietro; Hatzidakis, Adam; Iaccarino, Vittorio

    2011-02-15

    We report five cases of female patients affected by symptomatic focal external genital venous malformations treated with percutaneous direct intralesional injection of sodium tetradecyl sulphate (STS). All patients were referred because of discomfort and pain when sexual intercourse was attempted. Direct sclerotherapy with 3% STS was performed on a day-hospital basis with the patient under local anesthesia. Complete resolution of the symptoms was achieved in all cases. No major adverse effects were reported. Direct intralesional sclerotherapy with STS may be considered a safe and effective method for the treatment of female external genital malformation without the necessity of general anesthesia for pain control.

  18. Needle Federated Search Engine

    Energy Science and Technology Software Center (ESTSC)

    2009-12-01

    The Idaho National Laboratory (INL) has combined a number of technologies, tools, and resources to accomplish a new means of federating search results. The resulting product is a search engine called Needle, an open-source-based tool that the INL uses internally for researching across a wide variety of information repositories. Needle has a flexible search interface that allows end users to point at any available data source. A user can select multiple sources such as commercialmore » databases (Web of Science, Engineering Index), external resources (WorldCat, Google Scholar), and internal corporate resources (email, document management system, library collections) in a single interface with one search query. In the future, INL hopes to offer this open-source engine to the public. This session will outline the development processes for making Needle™s search interface and simplifying the federation of internal and external data sources.« less

  19. Needle Federated Search Engine

    SciTech Connect

    2009-12-01

    The Idaho National Laboratory (INL) has combined a number of technologies, tools, and resources to accomplish a new means of federating search results. The resulting product is a search engine called Needle, an open-source-based tool that the INL uses internally for researching across a wide variety of information repositories. Needle has a flexible search interface that allows end users to point at any available data source. A user can select multiple sources such as commercial databases (Web of Science, Engineering Index), external resources (WorldCat, Google Scholar), and internal corporate resources (email, document management system, library collections) in a single interface with one search query. In the future, INL hopes to offer this open-source engine to the public. This session will outline the development processes for making Needle™s search interface and simplifying the federation of internal and external data sources.

  20. Fine needle aspiration of the thyroid

    MedlinePlus

    Thyroid nodule fine needle aspirate biopsy; Biopsy - thyroid - skinny-needle; Skinny-needle thyroid biopsy ... cleaned. A thin needle is inserted into the thyroid, and a sample of thyroid cells and fluid ...

  1. Fine needle aspiration of the thyroid

    MedlinePlus

    Thyroid nodule fine needle aspirate biopsy; Biopsy - thyroid - skinny-needle; Skinny-needle thyroid biopsy ... under your shoulders and your neck extended. The biopsy site is cleaned. A thin needle is inserted ...

  2. Thermal insulator

    SciTech Connect

    Yamamoto, R.; Asada, Y.; Matsuo, Y.; Mikoda, M.

    1985-07-16

    A thermal insulator comprises an expanded resin body having embedded therein an evacuated powder insulation portion which consists of fine powder and a container of film-like plastics or a film-like composite of plastics and metal for enclosing the powder. The resin body has been expanded by a Freon gas as a blowing agent. Since a Freon gas has a larger molecular diameter than the constituent gases of air, it is less likely to permeate through the container than air. Thus present invention provides a novel composite insulator which fully utilizes the benefits of vacuum insulation without necessitating a strong and costly material for a vacuum container.

  3. Intralesional Sclerotherapy - A Novel Approach for The Treatment of Intraoral Haemangiomas

    PubMed Central

    Reddy, G.Siva Prasad; Reddy, G. Venkateshwara; Priyadarshini, B. Srilatha; Sree, P. Karuna

    2016-01-01

    In infancy and childhood haemangiomas are the most common neoplasms in head and neck region with an occurrence of about 60%. Approximately 40%-50% of all haemangiomas resolve incompletely, leaving permanent changes in the skin, such as telangiectases, epidermal atrophy, hypopigmentation or redundant skin with fibro-fatty residue but a few stubborn, problematic haemangiomas may result in serious disfigurement and dysfunction, and even become life-threatening. Most haemangiomas are managed by conservative methods that include corticosteroids (either systemic or local injection), sclerotherapy, interferon-alpha, laser therapy, embolization, cryotherapy, and radiation. Due to risk of haemorrhaging, surgical removal for small vascular lesions is not considered and it is more invasive than sclerotherapy. This case report presents the efficacy of intralesional sclerotherapy for the management of haemangiomas on dorsum and lateral border of tongue. PMID:26894188

  4. Intralesional Sclerotherapy - A Novel Approach for The Treatment of Intraoral Haemangiomas.

    PubMed

    Reddy, G Siva Prasad; Reddy, G Venkateshwara; Reddy, K Sravan Kumar; Priyadarshini, B Srilatha; Sree, P Karuna

    2016-01-01

    In infancy and childhood haemangiomas are the most common neoplasms in head and neck region with an occurrence of about 60%. Approximately 40%-50% of all haemangiomas resolve incompletely, leaving permanent changes in the skin, such as telangiectases, epidermal atrophy, hypopigmentation or redundant skin with fibro-fatty residue but a few stubborn, problematic haemangiomas may result in serious disfigurement and dysfunction, and even become life-threatening. Most haemangiomas are managed by conservative methods that include corticosteroids (either systemic or local injection), sclerotherapy, interferon-alpha, laser therapy, embolization, cryotherapy, and radiation. Due to risk of haemorrhaging, surgical removal for small vascular lesions is not considered and it is more invasive than sclerotherapy. This case report presents the efficacy of intralesional sclerotherapy for the management of haemangiomas on dorsum and lateral border of tongue. PMID:26894188

  5. Efficacy of Intralesional Amphotericin B for the Treatment of Cutaneous Leishmaniasis

    PubMed Central

    Goyonlo, Vahid Mashayekhi; Vosoughi, Elham; Kiafar, Bita; Nahidi, Yalda; Momenzadeh, Akram; Taheri, Ahmad Reza

    2014-01-01

    Background: Antimoniate compounds have been used as gold standard treatment for cutaneous leishmaniasis since many years ago, but with increase in incidence of drug as well as individual contraindications, more attention has been given to alternative treatments. Aim: The aim of this study was to evaluate the efficacy of intralesional amphotericin B as an alternative treatment for cutaneous leishmaniasis in Mashhad, Iran, during 2007-2009. Materials and Methods: Non-random sampling from both sexes and without any age limitation of cases eligible for this alternative treatment was done. Size and induration of lesions were measured before beginning and weakly during the treatment. Amphotericin B (2 mg/ml) was injected into lesions weekly for up to 12 weeks and the cases were followed up for the treatment responses, possible side effects and recurrence of the disease. Results: A total of 93 patients with a mean age of 20.81 ± 15.26 years were included in this study. At the end of 12th week, 61.4% of the patients were recovered completely (more than 90% reduction in size and induration), 21.6% had partial remission (60-90% reduction in size and induration), and 17% had less than 60% reduction in size and induration of skin lesions. Injection side effects were insignificant and did not lead to premature discontinuation of treatment in any patients. Conclusion: Weekly intralesional injection of amphotericin B looks promising, considering the fact that most of the patients in this study were resistant to antimoniates. PMID:25484415

  6. Intralesional immunotherapy for difficult to treat warts with Mycobacterium w vaccine

    PubMed Central

    Garg, Shilpa; Baveja, Sukriti

    2014-01-01

    Background: Immunotherapy is an evolving therapeutic modality for the treatment of warts. We conducted a study to assess the efficacy and safety of intralesional Mycobacterium w vaccine for the treatment of warts at sites that were difficult to treat. Materials and Methods: Thirty patients with at least one wart present on either the plantar surface of their feet, palms, volar aspect of their fingers, or periungual or subungual region, were treated with 0.1 ml of killed Mycobacterium w vaccine given intralesionally in a single wart, without any prior sensitisation dose. Thereafter, a single injection of 0.1 ml of vaccine was given at intervals of four weeks in a single wart till there was complete resolution of the warts or a maximum of 10 injections. Treatment was stopped if there was no response after three injections. The patients were followed up for at least six months. Results: Out of the 30 patients, 28 (93.33%) patients had complete resolution of their warts, both at the injected and distant sites. The mean (SD) time for complete clearance of warts was 43.71(32.82) days and the mean (SD) dose of vaccine that was required for complete clearance of warts was 0.186 ml (0.101). Four patients (14.28%) had a recurrence of warts. The treatment was well-tolerated and the side effects were reversible in the majority of the patients. Conclusion: In comparison to the earlier studies using Mycobacterium w vaccine for the treatment of warts, our study was different in the following aspects: No sensitisation dose was given, only a single wart was injected at a time and the duration between the period of injections was increased to four weeks. With all these changes we eliminated the complications due to the sensitisation dose and achieved good results. This study provides new insight into the dose and schedule of treatment of this evolving therapeutic modality. PMID:25722598

  7. Intralesional epidermal growth factor for diabetic foot wounds: the first cases in Turkey

    PubMed Central

    Ertugrul, Bulent M.; Buke, Cagri; Ersoy, Ozlem Saylak; Ay, Bengisu; Demirez, Dilek Senen; Savk, Oner

    2015-01-01

    Background Intralesional recombinant epidermal growth factor (EGF) was produced in the Centre for Genetic Engineering and Biotechnology (CIGB), Cuba, in 1988 and licensed in 2006. Because it may accelerate wound healing, it is a potential new treatment option in patients with a diabetic foot wound (whether infected or not) as an adjunct to standard treatment (i.e. debridement, antibiotics). We conducted the initial evaluation of EGF for diabetic foot wounds in Turkey. Methods We enrolled 17 patients who were hospitalized in various medical centers for a foot ulcer and/or infection and for whom below the knee amputation was suggested to all except one. All patients received 75 μg intralesional EGF three times per week on alternate days. Results The appearance of new granulation tissue on the wound site (≥75%) was observed in 13 patients (76%), and complete wound closure was observed in 3 patients (18%), yielding a ‘complete recovery’ rate of 94%. The most common side effects were tremor (n=10, 59%) and nausea (n=6, 35%). In only one case,a serious side effect requiring cessation of EGF treatment was noted. That patient experienced severe hypotension at the 16th application session, and treatment was discontinued. At baseline, a total of 21 causative bacteria were isolated from 15 patients, whereascultures were sterile in two patients. The most frequently isolated species was Pseudomonas aeruginosa. Conclusion Thus, this preliminary study suggests that EGF seems to be a potential adjunctive treatment option in patients with limb-threatening diabetic foot wounds. PMID:26268583

  8. Automotive Insulation

    NASA Technical Reports Server (NTRS)

    1997-01-01

    Under a Space Act Agreement between Boeing North America and BSR Products, Space Shuttle Thermal Protection System (TPS) materials are now used to insulate race cars. BSR has created special TPS blanket insulation kits for use on autos that take part in NASCAR events, and other race cars through its nationwide catalog distribution system. Temperatures inside a race car's cockpit can soar to a sweltering 140 to 160 degrees, with the extreme heat coming through the engine firewall, transmission tunnel, and floor. It is common for NASCAR drivers to endure blisters and burns due to the excessive heat. Tests on a car insulated with the TPS material showed a temperature drop of some 50 degrees in the driver's cockpit. BSR-TPS Products, Inc. now manufactures insulation kits for distribution to race car teams around the world.

  9. Thermal Insulation

    NASA Technical Reports Server (NTRS)

    1984-01-01

    Commercially known as Solimide, Temptronics, Inc.'s thermal insulation has application in such vehicles as aircraft, spacecraft and surface transportation systems (i.e. rapid transit cars, trains, buses, and ships) as acoustical treatment for door, wall, and ceiling panels, as a means of reducing vibrations, and as thermal insulation (also useful in industrial equipment). Product originated from research conducted by Johnson Space Center on advanced flame-resistant materials for minimizing fire hazard in the Shuttle and other flight vehicles.

  10. Needle bar for warp knitting machines

    DOEpatents

    Hagel, Adolf; Thumling, Manfred

    1979-01-01

    Needle bar for warp knitting machines with a number of needles individually set into slits of the bar and having shafts cranked to such an extent that the head section of each needle is in alignment with the shaft section accommodated by the slit. Slackening of the needles will thus not influence the needle spacing.

  11. Elastosis perforans serpiginosa: a case successfully treated with intralesional steroids and topical allium cepa-allantoin-pentaglycan gel.

    PubMed

    Campanati, Anna; Martina, Emanuela; Giuliodori, Katia; Ganzetti, Giulia; Marconi, Barbara; Conta, Irene; Giangiacomi, Mirella; Offidani, Annamaria

    2014-01-01

    Elastosis perforans serpiginosa is a rare skin disease in which abnormal elastic fibers, other connective tissue elements, and cellular debris are expelled from the papillary dermis through the epidermis. Three clinical variants of EPS can be detected: idiopathic, reactive, and drug-induced. Clinically it consists of small horny or umbilicated papules arranged in a linear, arciform, circular, or serpiginous pattern. It usually occurs in young adults and shows a predilection for the head and neck. The lesions are generally asymptomatic or slightly itching. Several treatments have been reported with poor long-term success; these include intralesional and topical corticosteroids, tazarotene, imiquimod, and cryotherapy. We report a case of 40-year-old black woman affected by elastosis perforans serpiginosa that was referred to our department and treated with intralesional injections of triamcinolone acetonide and topical application of allium cepa-allantoin-pentaglycan gel. PMID:24964949

  12. Comparative study of intralesional steroid injection and cryotherapy in alopecia areata

    PubMed Central

    Amirnia, Mehdi; Mahmoudi, Seyed-Sajjad; Karkon-Shayan, Farid; Alikhah, Hossein; Piri, Reza; Naghavi-Behzad, Mohammad; Ranjkesh, Mohammad-Reza

    2015-01-01

    Background and Objectives: Alopecia areata (AA) is a common, non-scarring type of hair loss, affecting approximately 2.1% of the population, many modality of treatment recommended like steroid injection, topical Immunotherapy and several systemic therapies. The aim of this study was to compare intralesional steroid injection and cryotherapyoutcomes in AA. Materials and Methods: In an analytical-descriptive study, 120 AA patients treated with intralesionalsteroid injection and 120 AA patients treated with cryotherapy were randomly selected. These two groups matched for location, duration and size of lesion and also matched for age and gender. From March 2011 to September 2013, the effect and complications of the therapies after 3, 6, 9 and 12 weeks were assessed and results were compared between the two groups. Results: Mean age of patients in steroid injection group was 30.2 ± 6.8 and in cryotherapy group was 31.8 ± 7.1. Sexual distribution in both groups was 56.7% and 43.3 % for male and female, respectively. Location of disease in 80% was in scalp and 20% was in face in both groups. The time of beginning response in steroid group was 4.13 ± 2.13 weeks and in cryotherapy group was 6.14 ± 0.29 weeks, difference between two groups was significant (P = 0.001). In term of clinical response at the end of study, in steroid group,20 patients (16.7%) no response, 32 patients (26.7%), moderate response and68 patients (56.7%) had a complete response, and also in cryotherapy group was, 52 patients (43.3%) no response, 40 patients (33.3%) moderate response and 28 patients (23.3%) had a complete response. There was significant different in complete response rate and steroid injection was more effective than cryotherapy(P < 0.05). Conclusion: As the cryotherapy isa considerable treatment of AA, alsothis study proposes intralesional injection of corticosteroid, as a replacement of AA therapy; particularly the short-term complications are not significantly different. PMID

  13. Efficacy of Holmium Laser Urethrotomy in Combination with Intralesional Triamcinolone in the Treatment of Anterior Urethral Stricture

    PubMed Central

    Kapoor, Ankur; Ganesamoni, Raguram; Nanjappa, Bhuvanesh; Sharma, Varun; Mete, Uttam K

    2012-01-01

    Purpose To evaluate the outcome of visual internal urethrotomy with a holmium:yttrium-aluminum-garnet laser along with intralesional triamcinolone injection. Materials and Methods Patients with an anterior urethral stricture less than 3 cm in length were evaluated by clinical history, physical examination, uroflowmetry, and retrograde urethrogram preoperatively. All patients were treated with holmium laser urethrotomy and intralesional triamcinolone (80 mg) injection under general or regional anesthesia. An 18 F urethral catheter was placed for 5 days. All patients were followed up for 12 months postoperatively by history, uroflowmetry, and if required, retrograde urethrogram or urethroscopy every 3 months. Results The mean age of the patients was 42.9 years (range, 14 to 70 years). The overall recurrence rate was 24%. The success rate in patients with strictures less than 1 cm in length was 95.8%, whereas that in patients with strictures of 1 to 3 cm in length was 57.7% (p=0.002). The outcome did not depend on age, duration of symptoms, etiology, or location of stricture. Conclusions Holmium laser urethrotomy with intralesional triamcinolone is a safe and effective minimally invasive therapeutic modality for urethral strictures. This procedure has an encouraging success rate, especially in those with stricture segments of less than 1 cm in length. PMID:23060998

  14. Efficacy of Topical Liposomal Amphotericin B versus Intralesional Meglumine Antimoniate (Glucantime) in the Treatment of Cutaneous Leishmaniasis

    PubMed Central

    Layegh, Pouran; Rajabi, Omid; Jafari, Mahmoud Reza; Emamgholi Tabar Malekshah, Parisa; Moghiman, Toktam; Ashraf, Hami; Salari, Roshanak

    2011-01-01

    Background. Topical treatment of cutaneous leishmaniasis is an attractive alternative avoiding toxicities of parenteral therapy while being administered through a simple painless route. Recently liposomal formulations of amphotericin B have been increasingly used in the treatment of several types of leishmaniasis. Aims. The efficacy of a topical liposomal amphotericin B formulation was compared with intralesional glucantime in the treatment of cutaneous leishmaniasis. Methods. From 110 patients, the randomly selected 50 received a topical liposomal formulation of amphotericin B into each lesion, 3–7 drops twice daily, according to the lesion's size and for 8 weeks. The other group of 60 patients received intralesional glucantime injection of 1-2 mL once a week for the same period. The clinical responses and side effects of both groups were evaluated weekly during the treatment course. Results. Per-protocol analysis showed no statistically significant difference between the two groups (P = 0.317, 95% confidence interval (CI) = 1.610 (0.632–4.101)). Moreover, after intention-to-treat analysis, the same results were seen (P = 0.650, 95% CI = 0.1.91 (0.560–2.530)). Serious post treatment side effects were not observed in either group. Conclusions. Topical liposomal amphotericin B has the same efficacy as intralesional glucantime in the treatment of cutaneous leishmaniasis. PMID:22174993

  15. The Clinical Effectiveness of Intralesional Injection of 2% Zinc Sulfate Solution in the Treatment of Common Warts

    PubMed Central

    Mohamed, Essam-elden Mohamed; Tawfik, Khaled Mohamed; Mahmoud, Asmaa Moneir

    2016-01-01

    Objective. To investigate the clinical efficacy and safety of intralesional injection of 2% zinc sulfate solution in the treatment of common warts. Patients and Methods. One hundred and twenty patients (78 females and 42 males) aged 5–55 years with 225 common warts participated in this prospective monocentric randomized study. All lesions were treated with intralesional injection of 2% zinc sulfate. Results. From 225 warts injected, 135 warts (60%) cured from the first session, 51 warts (22.67%) cured from the second session, and 12 warts (5.33%) cured from the third session. There is no significant relation between improvement and patient's ages, duration, or number of warts (P > 0.05). All patients complained from pain during injection, and all treated lesions showed redness, tenderness, and swelling in the first 3 days after injection. Late complications were postinflammatory hyperpigmentation in 90 patients (75%), scaring in 9 patients (7.5%), and ulceration in 3 patients (2.5%). Recurrence occurred in 3 lesions (1.33%). Conclusion. The clinical data indicate that intralesional injection of 2% zinc sulfate is an effective maneuver in the treatment of common warts; however, its associated complications limit its use. PMID:27123361

  16. Radiation Insulation

    NASA Technical Reports Server (NTRS)

    1995-01-01

    The Apollo and subsequent spacecraft have had highly effective radiation barriers; made of aluminized polymer film, they bar or let in heat to maintain consistent temperatures inside. Tech 2000, formerly Quantum International Corporation used the NASA technology in its insulating materials, Super "Q" Radiant Barrier, for home, industry and mobile applications. The insulation combines industrial aluminum foil overlaid around a core of another material, usually propylene or mylar. The outer layer reflects up to 97 percent of heat; the central layer creates a thermal break in the structure and thus allows low radiant energy emission. The Quantum Cool Wall, used in cars and trucks, takes up little space while providing superior insulation, thus reducing spoilage and costs. The panels can also dampen sound and engine, exhaust and solar heat.

  17. Insulation Material

    NASA Technical Reports Server (NTRS)

    1984-01-01

    Manufactured by Hitco Materials Division of Armco, Inc. a ceramic fiber insulation material known as Refrasil has been used extensively as a heat-absorbing ablative reinforcement for such space systems as rocket motor nozzles, combustion chambers, and re-entry shields. Refrasil fibers are highly porous and do not melt or vaporize until fibers exceed 3,100 degrees Fahrenheit. Due to these and other properties, Refrasil has found utility in a number of industrial high temperature applications where glass, asbestos and other materials fail. Hitco used this insulation to assist Richardson Co., Inc. in the manufacturing of hard rubber and plastic molded battery cases.

  18. Tadalafil once daily and intralesional verapamil injection: A new therapeutic direction in Peyronie's disease

    PubMed Central

    Dell’Atti, Lucio

    2015-01-01

    Introduction: The aim of this study was to evaluate the combination of intralesional verapamil injection (IVI) therapy with and tadalafil in men affected by Peyronie's disease (PD). Materials and Methods: In this study, 59 patients diagnosed with PD, were divided into three groups. Group A (GA) counted 23 patients treated with IVI; Group B (GB) treated 19 patients with tadalafil 5 mg once a day, and Group C (GC) treated 17 patients with IVI and tadalafil for 3 months. There were assessed at baseline and follow-up: Erectile function, presence and severity of painful erections, penile plaque size and penile curvature degree. Results: After 3 months pain resolved completely in 57% cases of GA, 61% of GB and 76% of GC; the final mean curvature degree further decreased in all groups without statistically significant differences; mean plaque size remained stable in GA: 1.57 versus 1.59 at baseline (P = 0.364) and GB: 1.51 versus 1.52 at baseline (P = 0,265), while a further decrease was evident in GC: 1.46 versus 1.58 at baseline (P = 0.03). Mean International Index of Erectile Function-5 score further improved significantly in the group treated with verapamil plus tadalafil: 23.1 versus 14.4 of GA and 18.2 of GB (P ≤ 0.01). Conclusions: The association of IVI and tadalafil showed better pain control while reducing penile curvature and erectile function, improving the quality of life. PMID:26229323

  19. Combination of intralesional verapamil and oral antioxidants for Peyronie's disease: a prospective, randomised controlled study.

    PubMed

    Favilla, V; Russo, G I; Privitera, S; Castelli, T; Madonia, M; La Vignera, S; Condorelli, R; Calogero, A E; Farina, F P; Cimino, S; Morgia, G

    2014-10-01

    The aim of this study was to evaluate the efficacy of the association of intralesional verapamil (ILV) injection with oral antioxidants compared with ILV monotherapy in patients with early onset of Peyronie's disease (PD) at 12-week follow-up. Group A (n = 52) received ILV 10 mg weekly for 12 weeks, while group B (n = 53) received ILV 10 mg weekly for 12 weeks + antioxidants orally one tablet once a day for 3 months. The main efficacy outcomes were the change in plaque size (PS), penile curvature (PC), visual analogue score (VAS), IIEF-15 and IIEF-15 subdomains. Both groups showed significant improvement from baseline to week 12 relative to PS and PC, while group B also in IIEF-15 score (mean difference: 5.51, P < 0.01) and VAS (mean difference: -2.71, P < 0.01). No significant differences were observed between both groups in PS and PC. Finally, both groups showed significant increase in orgasmic function (IIEF-OF) and overall satisfaction (IIEF-OS), while group B showed significant improvement also in intercourse satisfaction (IIEF-IS). Significant differences were found relative to IIEF-OF, IIEF-IS, IIEF-OS and VAS scores in the group B compared with group A. Patients affected by PD may benefit from combination treatment with ILV and oral antioxidants thanks to the improvement in IIEF-OF, IIEF-IS and IIEF-OS at 12 weeks. PMID:24124921

  20. [Effect of intralesional treatment with emetine hydrochloride on Leishmania (Viannia) braziliensis in hamsters].

    PubMed

    Cazorla, D; Yépez, J; Añez, N; Sánchez de Mirt, A

    2001-03-01

    The therapeutic effect of the emetine hydrochloride alkaloid administered intralesionally was compared with that of standard parenteral treatment with Glucantime in outbred male hamsters experimentally infected with 4 x 10(3) amastigotes of Leishmania (Viannia) braziliensis. Both chemotherapeutic agents reduced significantly (P < 0.01) the average lesion sizes in experimental animals in comparison with those untreated. The alkaloid infiltration was found to be as effective as the antimonial injection for clinical resolution. The ultrastructural effects on the Leishmania parasites exposed to emetine were observed mainly in the inner cytoplasm, which appeared disorganized, pycnotic and with loss of morphological definition; however, any known emetine hydrochloride action mechanism factor could not be directly related with ultrastructure effects detected on leishmanial parasites. Smears, conventional histopathology, culture in NNN medium and indirect immunoperoxidase method showed viable amastigotes in nodules and/or scars of all the evaluated hamsters 75 to 230 days after the end of treatment. These findings suggest that measurement of the size of cutaneous leishmania lesions does not appear to be a valid criterion for evaluating the efficiency of chemotherapy in experimental LT. Detection of leishmania parasites in the lesion scars, supports the hypothesis that man could be considered as an domestic reservoir. PMID:11294031

  1. Needle Thoracotomy in Trauma.

    PubMed

    Rottenstreich, Misgav; Fay, Shmuel; Gendler, Sami; Klein, Yoram; Arkovitz, Marc; Rottenstreich, Amihai

    2015-12-01

    Tension pneumothorax is one of the leading causes of preventable death in trauma patients. Needle thoracotomy (NT) is the currently accepted first-line intervention but has not been well validated. In this review, we have critically discussed the evidence for NT procedure, re-examined the recommendations by the Advanced Trauma Life Support organization and investigated the safest and most effective way of NT. The current evidence to support the use of NT is limited. However, when used, it should be applied in the 2nd intercostal space at midclavicular line using a catheter length of at least 4.5 cm. Alternative measures should be studied for better prehospital management of tension pneumothorax. PMID:26633663

  2. Kondo insulators

    SciTech Connect

    Fisk, Z.; Sarrao, J.L.; Thompson, J.D.

    1994-10-01

    The Kondo insulating materials present a particularly simple limiting case of the strongly correlated electron lattice problem: one occupied f-state interacting with a single half-filled conduction band. Experiment shows that the solution to this problem has some remarkably simple aspects. Optical conductivity data display the strong coupling nature of this physics.

  3. Radiation Insulation

    NASA Technical Reports Server (NTRS)

    1987-01-01

    Radiation insulation technology from Apollo and subsequent spacecraft was used to develop superinsulators, used by makers of cold weather apparel, to make parkas, jackets, boots and outdoor gear such as sleeping bags. The radiant barrier technology offers warmth retention at minimal weight and bulk.

  4. Insulation Material

    NASA Technical Reports Server (NTRS)

    1987-01-01

    Apex Mills Corporation's superinsulators are used by makers of cold weather apparel, parkas, jackets, boots and outdoor gear such as sleeping bags. Their attraction in such applications is that radiant barrier insulation offers excellent warmth retention at minimal weight and bulk.

  5. Microsphere insulation systems

    NASA Technical Reports Server (NTRS)

    Allen, Mark S. (Inventor); Willen, Gary S. (Inventor); Mohling, Robert A. (Inventor)

    2005-01-01

    A new insulation system is provided that contains microspheres. This insulation system can be used to provide insulated panels and clamshells, and to insulate annular spaces around objects used to transfer, store, or transport cryogens and other temperature-sensitive materials. This insulation system provides better performance with reduced maintenance than current insulation systems.

  6. Active post-marketing surveillance of the intralesional administration of human recombinant epidermal growth factor in diabetic foot ulcers

    PubMed Central

    2013-01-01

    Background After several exploratory and confirmatory clinical trials, the intralesional administration of human recombinant epidermal growth factor (hrEGF) has been approved for the treatment of advanced diabetic foot ulcers (DFU). The aim of this work was to evaluate the effectiveness and safety of this procedure in medical practice. Methods A prospective, post-marketing active pharmacosurveillance was conducted in 41 hospitals and 19 primary care polyclinics. Patients with DFU received hrEGF, 25 or 75 μg, intralesionally 3 times per week until complete granulation of the ulcer or 8 weeks maximum, adjuvant to standard wound care. Outcomes measured were complete granulation, amputations, and adverse events (AE) during treatment; complete lesion re-epithelization and relapses in follow-up (median: 1.2; maximum 4.2 years). Results The study included 1788 patients with 1835 DFU (81% Wagner’s grades 3 or 4; 43% ischemic) treated from May 2007 to April 2010. Complete granulation was observed in 76% of the ulcers in 5 weeks (median). Ulcer non-ischemic etiology (OR: 3.6; 95% CI: 2.8-4.7) and age (1.02; 1.01-1.03, for each younger year) were the main variables with influence on this outcome. During treatment, 220 (12%) amputations (171 major) were required in 214 patients, mostly in ischemic or Wagner’s grade 3 to 5 ulcers. Re-epithelization was documented in 61% of the 1659 followed-up cases; 5% relapsed per year. AE (4171) were reported in 47% of the subjects. Mild or moderate local pain and burning sensation, shivering and chills, were 87% of the events. Serious events, not related to treatment, occurred in 1.7% of the patients. Conclusions The favorable benefit/risk balance, confirms the beneficial clinical profile of intralesional hrEGF in the treatment of DFUs. PMID:24004460

  7. Fabrication of tungsten wire needles

    SciTech Connect

    Roder, A.

    1983-02-01

    Fine point needles for field emissoin are conventionally produced by electrolytically or chemically etching tungsten wire. Points formed in this manner have a typical tip radius of about 0.5 microns and a cone angle of some 30 degrees. The construction of needle matrix detector chambers has created a need for tungsten needles whose specifications are: 20 mil tungsten wire, 1.5 inch total length, 3 mm-long taper (resulting in a cone angle of about 5 degrees), and 25 micron-radius point (similar to that found on sewing needles). In the process described here for producing such needles, tungsten wire, immersed in a NaOH solution and in the presence of an electrode, is connected first to an ac voltage and then to a dc supply, to form a taper and a point on the end of the wire immersed in the solution. The process parameters described here are for needles that will meet the above specifications. Possible variations will be discussed under each approprite heading.

  8. Cohomological Insulators

    NASA Astrophysics Data System (ADS)

    Alexandradinata, A.; Wang, Zhijun; Bernevig, B. Andrei

    We present a cohomological classification of insulators, in which we extend crystal symmetries by Wilson loops. Such an extended group describes generalized symmetries that combine space-time transformations with quasimomentum translations. Our extension generalizes the construction of nonsymmorphic space groups, which extend point groups by real-space translations. Here, we further extend nonsymmorphic groups by reciprocal translations, thus placing real and quasimomentum space on equal footing. From a broader perspective, cohomology specifies not just the symmetry group, but also the quasimomentum manifold in which the symmetry acts - both data are needed to specify the band topology. In this sense, cohomology underlies band topology.

  9. Combined excision and intralesional bevacizumab for sebaceous carcinoma of the eyelid in an Amur tiger (Panthera tigris altaica).

    PubMed

    Edelmann, Michele L; Utter, Mary L; Klein, Lin V; Wotman, Kathryn L

    2013-05-01

    An 18-year-old zoo-kept female Amur tiger presented with an approximately 5 mm diameter lateral canthal eyelid mass in the left eye which grossly appeared red and irregular. The mass was completely excised via lateral canthoplasty. Histopathologic evaluation was consistent with a diagnosis of sebaceous cell carcinoma, which is a potentially aggressive cutaneous neoplasm. The sebaceous carcinoma recurred within 3 months and slowly increased in size until a second surgical excision was performed 9 months following the first surgery. The second surgical excision was combined with intralesional injection of 10 mg of the antiangiogenic drug bevacizumab. Histology confirmed the diagnosis. The tiger was euthanized 16 months postoperatively for reasons unrelated to, and without recurrence of, the eyelid neoplasm. At postmortem, no gross periocular or metastatic lesions were noted, and histopathology of the lateral canthus provided no evidence of recurrence. Surgical excision combined with intralesional bevacizumab treatment induced life-long resolution of the sebaceous carcinoma. Bevacizumab treatment may be associated with the regression of periocular angiogenic proliferative conditions, including neoplasia, by inhibiting angiogenesis. PMID:22857265

  10. Clinical features, epidemiology, and efficacy and safety of intralesional antimony treatment of cutaneous leishmaniasis: recent experience in Turkey.

    PubMed

    Uzun, Soner; Durdu, Murat; Culha, Gulnaz; Allahverdiyev, Adil M; Memisoglu, Hamdi R

    2004-08-01

    A total of 1,030 patients, 40.2% men and 59.8% women, identified during the period of October 1998 to November 2002 as having cutaneous leishmaniasis (CL), were studied; 1,431 lesions were identified in the 1,030 patients. One lesion was present in 80.7% of the patients. The size of the lesions (longest axis) was 13.6 mm (standard, 12.1 mm; range 3-150 mm). Most of the lesions were of the papular type (51.2%), although several atypical clinical presentations of CL were observed. The duration of the disease ranged between 1 and 72 mo (mean duration, 10.8 mo). The clinical suspicion of CL was confirmed by the observation of amastigotes on lesion tissue samples stained by Giemsa. The test was positive in 851 of 1,030 patients (82.6%). Intralesional meglumine antimonate solution (85 mg Sb/ml, 0.2-1 ml, depending on the size of the lesion) weekly until complete cure or up to 20 wk was used for first-line therapy of 890 patients (86.4%). We found that this regimen of intralesional Sb has an efficacy of 97.2% with a low relapse rate of 3.9% and no serious adverse side effects. PMID:15357081

  11. Treatment of localized Langerhans' cell histiocytosis of the mandible with intralesional steroid injection: report of a case.

    PubMed

    Esen, Alparslan; Dolanmaz, Doğan; Kalayci, Abdullah; Günhan, Omer; Avunduk, Mustafa Cihat

    2010-02-01

    Localized Langerhans cell histiocytosis (LLCH), formerly known as eosinophilic granuloma, mainly affects the skull, mandible, vertebrae, and ribs in children and the long bones of adults. Symptoms range from none to pain, swelling, and tenderness over the site of the lesion. General malaise and fever occasionally are present. Radiographically, lesions appear as radiolucent areas with well demarcated borders. LLCH may resolve spontaneously after biopsy in a period of months to years. However, if features include continuous pain, decrease of function, pathologic fractures, migration and resorption of teeth, or rapid progression, then active treatment needs to be considered. Treatment approaches include surgery, radiotherapy, chemotherapy, and intralesional injection of corticosteroids. In children with mandibular LLCH, 1 dose of methyprednisolone succinate injection has proven to be adequate. However, injections have not been performed in cases involving pathologic fracture. We report a new case of LLCH of the mandible that caused a pathologic fracture in an adult patient. Repeated intralesional corticosteroid injections resulted in fracture line disappearance within 14 months and lesion healing by the end of the 36-month follow-up. PMID:20123398

  12. Tank Insulation

    NASA Technical Reports Server (NTRS)

    1979-01-01

    For NASA's Apollo program, McDonnell Douglas Astronautics Company, Huntington Beach, California, developed and built the S-IVB, uppermost stage of the three-stage Saturn V moonbooster. An important part of the development task was fabrication of a tank to contain liquid hydrogen fuel for the stage's rocket engine. The liquid hydrogen had to be contained at the supercold temperature of 423 degrees below zero Fahrenheit. The tank had to be perfectly insulated to keep engine or solar heat from reaching the fuel; if the hydrogen were permitted to warm up, it would have boiled off, or converted to gaseous form, reducing the amount of fuel available to the engine. McDonnell Douglas' answer was a supereffective insulation called 3D, which consisted of a one-inch thickness of polyurethane foam reinforced in three dimensions with fiberglass threads. Over a 13-year development and construction period, the company built 30 tanks and never experienced a failure. Now, after years of additional development, an advanced version of 3D is finding application as part of a containment system for transporting Liquefied Natural Gas (LNG) by ship.

  13. Insulators for high voltages

    SciTech Connect

    Looms, J.S.T.

    1987-01-01

    This book describes electrical insulators for high voltage applications. Topics considered include the insulating materials, the manufacture of wet process porcelain, the manufacture of tempered glass, the glass-fibre core, the polymeric housing, the common problem - terminating an insulator, mechanical constraints, the physics of pollution flashover, the physics of contamination, testing of insulators, conclusions from testing, remedies for flashover, insulators for special cases, interference and noise, and the insulator of the future.

  14. Central Retinal and Posterior Ciliary Artery Occlusion After Intralesional Injection of Sclerosant to Glabellar Subcutaneous Hemangioma

    SciTech Connect

    Matsuo, Toshihiko; Fujiwara, Hiroyasu; Gobara, Hideo; Mimura, Hidefumi; Kanazawa, Susumu

    2009-03-15

    The aim of this study is to describe vision loss caused by central retinal artery and posterior ciliary artery occlusion as a consequence of sclerotherapy with a polidocanol injection to a glabellar hemangioma. An 18-year-old man underwent direct injection with a 23-gauge needle of 1 mL of a polidocanol-carbon dioxide emulsion into the glabellar subcutaneous hemangioma under ultrasound visualization of the needle tip by radiologists. He developed lid swelling the next day, and 3 days later at referral, the visual acuity in the left eye was no light perception. Funduscopy revealed central retinal artery occlusion and fluorescein angiography disclosed no perfusion at all in the left fundus, indicating concurrent posterior ciliary artery occlusion. The patient also showed mydriasis, blepharoptosis, and total external ophthalmoplegia on the left side. Magnetic resonance imaging demonstrated the swollen medial rectus muscle. In a month, blepharoptosis and ophthalmoplegia resolved but the visual acuity remained no light perception. Sclerosing therapy for facial hemangioma may develop a severe complication such as permanent visual loss.

  15. Needle biopsy of the breast.

    PubMed

    Millis, R R

    1984-01-01

    Recently, there has been a considerable increase in the use of both fine-needle aspiration biopsy (aspiration cytology) and tissue-core needle biopsy of the breast. In patients with suspected breast cancer, needle biopsy is frequently used to confirm the diagnosis before treatment is planned. This allows a more thoughtful approach to the patient and full screening for possible metastatic disease prior to definitive surgery. Needle biopsy techniques are simple, rapid, can be performed in the doctor's office, and save time, equipment, and hospital beds. Complications are few. Aspiration cytology has the advantage that it is quick to perform, the preparation can be examined almost immediately and, in the event of an unsatisfactory smear, the procedure can be repeated. However, the diagnosis is based on purely cytological evaluation, and the information obtained is somewhat limited. Reported accuracy rates range from 42 to 96%. False positive reports are rare but have occurred in most centers, and a high degree of accuracy will only be obtained by experienced practitioners. Tissue-core needle biopsy has the advantage that the diagnosis is based on histopathological assessment, but the procedure is slightly more time consuming, is more traumatic for the patient, and the equipment is more expensive. Accuracy rates range from 67 to 98.5%. During the past 4 years, 329 tissue-core (Tru-Cut) biopsies have been performed in the Guy's Hospital Breast Unit, with an accuracy rate of 83% in the diagnosis of carcinoma. The procedure has been acceptable to most patients, and complications have been minimal. Studies comparing the use of aspiration cytology and tissue-core needle biopsy in the diagnosis of mammary carcinoma have produced variable results. Both methods have advantages and disadvantages, and the choice of technique must depend on the clinical situation and the preferences and skills of the practitioners involved in the management of the patient. PMID:6377049

  16. Does Needle Rotation Improve Lesion Targeting?

    PubMed Central

    Badaan, Shadi; Petrisor, Doru; Kim, Chunwoo; Mozer, Pierre; Mazilu, Dumitru; Gruionu, Lucian; Patriciu, Alex; Cleary, Kevin; Stoianovici, Dan

    2011-01-01

    Background Image-guided robots are manipulators that operate based on medical images. Perhaps the most common class of image-guided robots are robots for needle interventions. Typically, these robots actively position and/or orient a needle guide, but needle insertion is still done by the physician. While this arrangement may have safety advantages and keep the physician in control of needle insertion, actuated needle drivers can incorporate other useful features. Methods We first present a new needle driver that can actively insert and rotate a needle. With this device we investigate the use of needle rotation in controlled in-vitro experiments performed with a specially developed revolving needle driver. Results These experiments show that needle rotation can improve targeting and may reduce errors by as much as 70%. Conclusion The new needle driver provides a unique kinematic architecture that enables insertion with a compact mechanism. Perhaps the most interesting conclusion of the study is that lesions of soft tissue organs may not be perfectly targeted with a needle without using special techniques, either manually or with a robotic device. The results of this study show that needle rotation may be an effective method of reducing targeting errors. PMID:21360796

  17. Magnetic needles and superparamagnetic cells

    PubMed Central

    Bryant, H C; Sergatskov, D A; Lovato, Debbie; Adolphi, Natalie L; Larson, Richard S; Flynn, Edward R

    2007-01-01

    Superparamagnetic nanoparticles can be attached in great numbers to pathogenic cells using specific antibodies so that the magnetically-labeled cells themselves become superparamagnets. The cells can then be manipulated and drawn out of biological fluids, as in a biopsy, very selectively using a magnetic needle. We examine the origins and uncertainties in the forces exerted on magnetic nanoparticles by static magnetic fields, leading to a model for trajectories and collection times of dilute superparamagnetic cells in biological fluids. We discuss the design and application of such magnetic needles and the theory of collection times. We compare the mathematical model to measurements in a variety of media including blood. PMID:17664592

  18. Secure Container For Discarded Hypodermic Needles

    NASA Technical Reports Server (NTRS)

    Lee, Angelene M.

    1992-01-01

    Container designed for safe retention of discarded blood-collecting hypodermic needles and similar sharp objects used in life-science experiments aboard spacecraft. Needles inserted through self-closing lid and retained magnetically. They are inserted, sharp end first, through spring-loaded flap. Long needles and needles on syringes cannot turn around in container. Can be emptied, cleaned, and reused. Used on Earth to provide unusually secure containment of sharp objects.

  19. 21 CFR 880.5580 - Acupuncture needle.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... in 21 CFR 801.109, (2) Device material biocompatibility, and (3) Device sterility. ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Acupuncture needle. 880.5580 Section 880.5580 Food... § 880.5580 Acupuncture needle. (a) Identification. An acupuncture needle is a device intended to...

  20. 21 CFR 880.5580 - Acupuncture needle.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... in 21 CFR 801.109, (2) Device material biocompatibility, and (3) Device sterility. ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Acupuncture needle. 880.5580 Section 880.5580 Food... § 880.5580 Acupuncture needle. (a) Identification. An acupuncture needle is a device intended to...

  1. 21 CFR 880.5580 - Acupuncture needle.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... in 21 CFR 801.109, (2) Device material biocompatibility, and (3) Device sterility. ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Acupuncture needle. 880.5580 Section 880.5580 Food... § 880.5580 Acupuncture needle. (a) Identification. An acupuncture needle is a device intended to...

  2. 21 CFR 880.5580 - Acupuncture needle.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... in 21 CFR 801.109, (2) Device material biocompatibility, and (3) Device sterility. ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Acupuncture needle. 880.5580 Section 880.5580 Food... § 880.5580 Acupuncture needle. (a) Identification. An acupuncture needle is a device intended to...

  3. Calcium silicate insulation structure

    DOEpatents

    Kollie, Thomas G.; Lauf, Robert J.

    1995-01-01

    An insulative structure including a powder-filled evacuated casing utilizes a quantity of finely divided synthetic calcium silicate having a relatively high surface area. The resultant structure-provides superior thermal insulating characteristics over a broad temperature range and is particularly well-suited as a panel for a refrigerator or freezer or the insulative barrier for a cooler or a insulated bottle.

  4. Multiple density layered insulator

    DOEpatents

    Alger, T.W.

    1994-09-06

    A multiple density layered insulator for use with a laser is disclosed which provides at least two different insulation materials for a laser discharge tube, where the two insulation materials have different thermoconductivities. The multiple layer insulation materials provide for improved thermoconductivity capability for improved laser operation. 4 figs.

  5. Multiple density layered insulator

    DOEpatents

    Alger, Terry W.

    1994-01-01

    A multiple density layered insulator for use with a laser is disclosed wh provides at least two different insulation materials for a laser discharge tube, where the two insulation materials have different thermoconductivities. The multiple layer insulation materials provide for improved thermoconductivity capability for improved laser operation.

  6. Unidentified intralesional and intracellular coccoid microorganism discovered in the young man with a diffuse erosive gastroduodenitis and multiple superficial ulcerations.

    PubMed

    Okada, Takayuki; Adkins, Graham

    2014-01-01

    A Helicobacter pylori-negative young Japanese man with dyspeptic symptoms suffered from a diffuse erosive gastroduodenitis and multiple superficial ulcerations. Histology and electron microscopic examinations on the biopsy specimens revealed the presence of multiple unidentified intralesional and intracellular coccoid microorganisms in the pathological gastroduodenal mucosa. Microaerophilic and anaerobic Gram-negative coccoid and filamentobacillary bacteria were cultured from the gastric aspirate. The triple therapy containing tetracycline for 14 days followed by 4 months treatment with omeprazole resulted in the resolution of the gastroduodenal pathology. The question, therefore, was raised regarding a possible role for the cultured coccoid bacteria in the pathogenesis. 16S rRNA gene sequence analysis of the isolated Gram-negative coccoid bacteria revealed a close relationship with Haemophilus haemolyticus. The unidentified coccoid microorganisms and cultured X and V factors independent coccoid bacteria, however, shared similar phenotypic, microbiological and pathological characteristics to the novel Gram-negative Streptococcaceae: Okadaella gastrococcus. PMID:24495976

  7. Peyronie's disease: intralesional treatment with interferon alpha-2A and evaluation of the results by magnetic resonance imaging.

    PubMed

    Polat, O; Gül, O; Ozbey, I; Ozdikici, M; Bayraktar, Y

    1997-01-01

    In this clinical study, to determine the therapeutic efficacy of interferon (IFN) treatment for Peyronie's disease, we applied interferon alpha-2A (IFN alpha-2A) intralesionally in the treatment of Peyronie plaques in 15 patients and results were evaluated by magnetic resonance imaging (MRI). Patients whose plaque sizes were 0.5 and 1 cm responded better to the treatment. There was about a 90% lessening in the sizes of the plaques of 1.5 cm, 83.3% of 2 cm, as the ones which were 0.5 cm and 1 cm disappeared completely after treatment. As a conclusion, the treatment of Peyronie's disease with IFN alpha-2A is effective and side effects are minimum. PMID:9406006

  8. Intralesional cryotherapy versus excision and corticosteroids or brachytherapy for keloid treatment: study protocol for a randomised controlled trial

    PubMed Central

    2013-01-01

    Background Keloids are a burden for patients due to physical, aesthetic and social complaints and treatment remains a challenge because of therapy resistance and high recurrence rates. The main goal of treatment is to improve the quality of life (QoL); this implies that, apart from surgical outcomes, patient-reported outcome measures (PROMs) need to be taken into account. Decision making in keloid treatment is difficult due to heterogeneity of the condition and the lack of comparative studies. Methods/Design This is a multicentre, randomised controlled open trial that compares 1) intralesional cryotherapy versus excision and corticosteroids for primary keloids, and 2) intralesional cryotherapy versus excision and brachytherapy for therapy-resistant keloids. The primary outcome is the Patient and Observer Scar Assessment Scale (POSAS), a 12-item scale (with score 12 indicating the best and 120 indicating the worst scar imaginable). A difference of six points on the total score is considered to be of clinical importance. Secondary outcomes are recurrence rates, volume reduction, Skindex-29 scores, SF-36 scores and complication rates. Primary and secondary outcome measurements are taken at baseline, and at 2, 12, 26 and 52 weeks postoperatively. For analysis, a linear mixed model is used. A total of 176 patients will be included over a period of 2.5 years. The protocol is approved by the Medical Ethics Committee of the Erasmus University Medical Centre Rotterdam and follows good clinical practice guidelines. Discussion The outcomes of this study will improve evidence-based decision making for the treatment of keloids, as well as patient education. Trial registration Dutch Trial Register NTR4151. PMID:24354714

  9. Combined Intralesional Neodymium-Doped Yttrium Aluminium Garnet Laser and Intratumoral Ligation as Curative Treatment for Craniofacial Arteriovenous Malformations.

    PubMed

    Rojvachiranonda, Nond; Lerdlum, Sukalaya; Mahatumarat, Charan

    2016-03-01

    Craniofacial arteriovenous malformation (AVM), although very rare, has been a very difficult problem to treat especially when it is large and involves important structures. Surgical resection often results in unacceptable complications but still not curative. At our institution, treatment by combined intralesional neodymium-doped yttrium aluminium garnet laser and intratumoral ligation has been successful in venous malformation. This minimally invasive technique was then applied to more challenging AVM on the head and neck. Disease control was studied using clinical parameters and magnetic resonance imaging.Four patients with moderate-to-severe (Schobinger 2-4) craniofacial AVM were treated by this technique from 2001 to 2011. Patient age ranged from 2 to 51 years (mean: 25 years). After 2 to 4 treatments and follow-up period of 1456 days, 3 (75%) were cured. One of them was infant with huge mass and secondary pulmonary hypertension. Clinical cure was achieved after 3 treatments without residual cardiovascular compromise. The other patient (25%) had cheek mass with intraorbital involvement. The authors did not treat periorbital lesion so as to avoid triggering intraorbital spreading. The rest of the cheek lesion was clinically and radiologically cured.Laser energy setting, ablative technique, and skin cooling are the main factors determining the success. Individualized laser settings and properly set endpoints can increase treatment effectiveness in shorter period. In conclusion, this minimally invasive technique was successful in curing AVM without complication. With more clinical study and development of soft tissue monitoring tools, it is possible that intralesional laser could become the treatment of choice for all cutaneous AVM. PMID:26825744

  10. Abrupt Intralesional Color Change on Dermoscopy as a New Indicator of Early Superficial Spreading Melanoma in a Japanese Woman.

    PubMed

    Sadayasu, Anna; Tanaka, Masaru; Maumi, Yoshifumi; Ikeda, Eriko; Sawada, Mizuki; Ishizaki, Sumiko; Murakami, Yoshiyuki; Fujibayashi, Mariko

    2015-01-01

    Diagnosis of superficial spreading melanoma in the early stage is often difficult, even with dermoscopy. We report the case of a 37-year-old Japanese woman with superficial spreading melanoma in her left buttock. The lesion developed 20 years before becoming visible and gradually enlarged over the past few years without any symptoms. Physical examination showed a well-demarcated dark-brown macule 10 mm in diameter. Dermoscopy demonstrated a central dark area with a blue-grey structureless area, a milky-red area with irregular blue-grey dots or globules suggestive of regression structures, and multifocal black pigmentation with whitish scaly areas. An abrupt intralesional change in color from a central dark area to a peripheral light-brown area was also seen. The peripheral area showed an atypical pigment network with an obscure mesh and holes. Histopathologic examination of the lesion showed acanthosis with melanocytic proliferation and nuclear atypia, a band-like lymphocytic infiltrate, melanophages and a few nests of melanocytes just beneath the epidermis. The epidermal melanocytes were positive for S-100, Melan-A and HMB-45, but the dermal nests of melanocytes were negative for HMB-45 and positive for S-100 and Melan-A. A diagnosis of superficial spreading melanoma with a tumor thickness of 0.4 mm (pT1aN0M0, stage 1A) was established based on the clinical, dermoscopic and histopathologic findings. This case suggests that dermoscopy is useful in the diagnosis of this condition. An abrupt intralesional change of color might be a new indicator of early superficial spreading melanoma. PMID:26269701

  11. Biomechanical performance of new cardiovascular needles.

    PubMed

    Thacker, J G; Ferguson, R E; Rodeheaver, G T; Edlich, R F

    2001-01-01

    Cardiovascular needles are now being manufactured from new stainless steel alloys containing high concentrations of nickel, Surgalloy and Ethalloy. The purpose of this study was to compare the biomechanical performance of a cardiovascular needle made of Surgalloy with a comparably sized needle made of Ethalloy. The parameters of biomechanical performance included sharpness, maintenance of sharpness, resistance to bending, and ductility. Because the biomechanical performance of these needles was remarkably similar, cardiovascular needles made of either the Surgalloy or Ethalloy alloys are recommended for cardiovascular surgery. PMID:11495105

  12. Brachytherapy needle deflection evaluation and correction

    SciTech Connect

    Wan Gang; Wei Zhouping; Gardi, Lori; Downey, Donal B.; Fenster, Aaron

    2005-04-01

    In prostate brachytherapy, an 18-gauge needle is used to implant radioactive seeds. This thin needle can be deflected from the preplanned trajectory in the prostate, potentially resulting in a suboptimum dose pattern and at times requiring repeated needle insertion to achieve optimal dosimetry. In this paper, we report on the evaluation of brachytherapy needle deflection and bending in test phantoms and two approaches to overcome the problem. First we tested the relationship between needle deflection and insertion depth as well as whether needle bending occurred. Targeting accuracy was tested by inserting a brachytherapy needle to target 16 points in chicken tissue phantoms. By implanting dummy seeds into chicken tissue phantoms under 3D ultrasound guidance, the overall accuracy of seed implantation was determined. We evaluated methods to overcome brachytherapy needle deflection with three different insertion methods: constant orientation, constant rotation, and orientation reversal at half of the insertion depth. Our results showed that needle deflection is linear with needle insertion depth, and that no noticeable bending occurs with needle insertion into the tissue and agar phantoms. A 3D principal component analysis was performed to obtain the population distribution of needle tip and seed position relative to the target positions. Our results showed that with the constant orientation insertion method, the mean needle targeting error was 2.8 mm and the mean seed implantation error was 2.9 mm. Using the constant rotation and orientation reversal at half insertion depth methods, the deflection error was reduced. The mean needle targeting errors were 0.8 and 1.2 mm for the constant rotation and orientation reversal methods, respectively, and the seed implantation errors were 0.9 and 1.5 mm for constant rotation insertion and orientation reversal methods, respectively.

  13. Ultrasound guided spine needle insertion

    NASA Astrophysics Data System (ADS)

    Chen, Elvis C. S.; Mousavi, Parvin; Gill, Sean; Fichtinger, Gabor; Abolmaesumi, Purang

    2010-02-01

    An ultrasound (US) guided, CT augmented, spine needle insertion navigational system is introduced. The system consists of an electromagnetic (EM) sensor, an US machine, and a preoperative CT volume of the patient anatomy. Three-dimensional (3D) US volume is reconstructed intraoperatively from a set of two-dimensional (2D) freehand US slices, and is coregistered with the preoperative CT. This allows the preoperative CT volume to be used in the intraoperative clinical coordinate. The spatial relationship between the patient anatomy, surgical tools, and the US transducer are tracked using the EM sensor, and are displayed with respect to the CT volume. The pose of the US transducer is used to interpolate the CT volume, providing the physician with a 2D "x-ray vision" to guide the needle insertion. Many of the system software components are GPU-accelerated, allowing real-time performance of the guidance system in a clinical setting.

  14. Insulated Foamy Viral Vectors.

    PubMed

    Browning, Diana L; Collins, Casey P; Hocum, Jonah D; Leap, David J; Rae, Dustin T; Trobridge, Grant D

    2016-03-01

    Retroviral vector-mediated gene therapy is promising, but genotoxicity has limited its use in the clinic. Genotoxicity is highly dependent on the retroviral vector used, and foamy viral (FV) vectors appear relatively safe. However, internal promoters may still potentially activate nearby genes. We developed insulated FV vectors, using four previously described insulators: a version of the well-studied chicken hypersensitivity site 4 insulator (650cHS4), two synthetic CCCTC-binding factor (CTCF)-based insulators, and an insulator based on the CCAAT box-binding transcription factor/nuclear factor I (7xCTF/NF1). We directly compared these insulators for enhancer-blocking activity, effect on FV vector titer, and fidelity of transfer to both proviral long terminal repeats. The synthetic CTCF-based insulators had the strongest insulating activity, but reduced titers significantly. The 7xCTF/NF1 insulator did not reduce titers but had weak insulating activity. The 650cHS4-insulated FV vector was identified as the overall most promising vector. Uninsulated and 650cHS4-insulated FV vectors were both significantly less genotoxic than gammaretroviral vectors. Integration sites were evaluated in cord blood CD34(+) cells and the 650cHS4-insulated FV vector had fewer hotspots compared with an uninsulated FV vector. These data suggest that insulated FV vectors are promising for hematopoietic stem cell gene therapy. PMID:26715244

  15. Dry needling — peripheral and central considerations

    PubMed Central

    Dommerholt, Jan

    2011-01-01

    Dry needling is a common treatment technique in orthopedic manual physical therapy. Although various dry needling approaches exist, the more common and best supported approach targets myofascial trigger points. This article aims to place trigger point dry needling within the context of pain sciences. From a pain science perspective, trigger points are constant sources of peripheral nociceptive input leading to peripheral and central sensitization. Dry needling cannot only reverse some aspects of central sensitization, it reduces local and referred pain, improves range of motion and muscle activation pattern, and alters the chemical environment of trigger points. Trigger point dry needling should be based on a thorough understanding of the scientific background of trigger points, the differences and similarities between active and latent trigger points, motor adaptation, and central sensitize application. Several outcome studies are included, as well as comments on dry needling and acupuncture. PMID:23115475

  16. Accuracy of Core Needle Biopsy Versus Fine Needle Aspiration Cytology for Diagnosing Salivary Gland Tumors

    PubMed Central

    Song, In Hye; Song, Joon Seon; Sung, Chang Ohk; Roh, Jong-Lyel; Choi, Seung-Ho; Nam, Soon Yuhl; Kim, Sang Yoon; Lee, Jeong Hyun; Baek, Jung Hwan; Cho, Kyung-Ja

    2015-01-01

    Background: Core needle biopsy is a relatively new technique used to diagnose salivary gland lesions, and its role in comparison with fine needle aspiration cytology needs to be refined. Methods: We compared the results of 228 ultrasound-guided core needle biopsy and 371 fine needle aspiration procedures performed on major salivary gland tumors with their postoperative histological diagnoses. Results: Core needle biopsy resulted in significantly higher sensitivity and more accurate tumor subtyping, especially for malignant tumors, than fine needle aspiration. No patient developed major complications after core needle biopsy. Conclusions: We recommend ultrasoundguided core needle biopsy as the primary diagnostic tool for the preoperative evaluation of patients with salivary gland lesions, especially when malignancy is suspected. PMID:26148740

  17. Navigational transbronchial needle aspiration, percutaneous needle aspiration and its future.

    PubMed

    Arias, Sixto; Yarmus, Lonny; Argento, A Christine

    2015-12-01

    Peripheral lung nodule evaluation represents a clinical challenge. Given that many nodules will be incidentally found with lung cancer screening following the publication of the National Lung Screening Trial (NLST), the goal is to find an accurate, safe and minimally-invasive diagnostic modality to biopsy the concerning lesions. Unfortunately, conventional bronchoscopic techniques provide a poor diagnostic yield of 18-62%. In recent years advances in technology have led to the introduction of electromagnetic navigational bronchoscopy (ENB) as a tool to guide sampling of peripheral lung nodules. The same principle has also recently been expanded and applied to the transthoracic needle biopsy, referred to as electromagnetic transthoracic needle aspiration (E-TTNA). An improved diagnostic yield has afforded this technology a recommendation by the 2013 3(rd) Edition ACCP Guidelines for the Diagnosis and Management of Lung Cancer which state that "in patients with peripheral lung lesions difficult to reach with conventional bronchoscopy, ENB is recommended if the equipment and the expertise are available (Grade 1C)". In this review we will discuss the technology, devices that are available, techniques and protocols, diagnostic yield, safety, cost effectiveness and more. PMID:26807280

  18. Navigational transbronchial needle aspiration, percutaneous needle aspiration and its future

    PubMed Central

    Arias, Sixto; Yarmus, Lonny

    2015-01-01

    Peripheral lung nodule evaluation represents a clinical challenge. Given that many nodules will be incidentally found with lung cancer screening following the publication of the National Lung Screening Trial (NLST), the goal is to find an accurate, safe and minimally-invasive diagnostic modality to biopsy the concerning lesions. Unfortunately, conventional bronchoscopic techniques provide a poor diagnostic yield of 18–62%. In recent years advances in technology have led to the introduction of electromagnetic navigational bronchoscopy (ENB) as a tool to guide sampling of peripheral lung nodules. The same principle has also recently been expanded and applied to the transthoracic needle biopsy, referred to as electromagnetic transthoracic needle aspiration (E-TTNA). An improved diagnostic yield has afforded this technology a recommendation by the 2013 3rd Edition ACCP Guidelines for the Diagnosis and Management of Lung Cancer which state that “in patients with peripheral lung lesions difficult to reach with conventional bronchoscopy, ENB is recommended if the equipment and the expertise are available (Grade 1C)”. In this review we will discuss the technology, devices that are available, techniques and protocols, diagnostic yield, safety, cost effectiveness and more. PMID:26807280

  19. Technical Note: Comparison of traditional needle vaccination to pneumatic, needle-free vaccination in sheep

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Lateral transmission of blood-borne diseases can occur when a single needle is used repeatedly to vaccinate livestock. Needle-free technology to vaccinate sheep without damaging the carcass, causing lesions, and/or leaving needle fragments, and eliciting a similar antibody response to traditional n...

  20. Geographical and climatic limits of needle types of one- and two-needled pinyon pines

    USGS Publications Warehouse

    Cole, K.L.; Fisher, J.; Arundel, S.T.; Cannella, J.; Swift, S.

    2008-01-01

    Aim: The geographical extent and climatic tolerances of one- and two-needled pinyon pines (Pinus subsect. Cembroides) are the focus of questions in taxonomy, palaeoclimatology and modelling of future distributions. The identification of these pines, traditionally classified by one- versus two-needled fascicles, is complicated by populations with both one- and two-needled fascicles on the same tree, and the description of two more recently described one-needled varieties: the fallax-type and californiarum-type. Because previous studies have suggested correlations between needle anatomy and climate, including anatomical plasticity reflecting annual precipitation, we approached this study at the level of the anatomy of individual pine needles rather than species. Location: Western North America. Methods: We synthesized available and new data from field and herbarium collections of needles to compile maps of their current distributions across western North America. Annual frequencies of needle types were compared with local precipitation histories for some stands. Historical North American climates were modelled on a c. 1-km grid using monthly temperature and precipitation values. A geospatial model (ClimLim), which analyses the effect of climate-modulated physiological and ecosystem processes, was used to rank the importance of seasonal climate variables in limiting the distributions of anatomical needle types. Results: The pinyon needles were classified into four distinct types based upon the number of needles per fascicle, needle thickness and the number of stomatal rows and resin canals. The individual needles fit well into four categories of needle types, whereas some trees exhibit a mixture of two needle types. Trees from central Arizona containing a mixture of Pinus edulis and fallax-type needles increased their percentage of fallax-type needles following dry years. All four needle types occupy broader geographical regions with distinctive precipitation regimes

  1. Transistor needle chip for recording in brain tissue

    NASA Astrophysics Data System (ADS)

    Felderer, Florian; Fromherz, Peter

    2011-07-01

    We report on a proof-of-principle experiment for the direct interfacing of transistors with intact brain tissue. A transistor needle chip (TNC) with a TiO2 surface is fabricated from a silicon-on-insulator wafer and impaled into an acute brain slice cut from hippocampus of the rat. While stimulating the Schaffer collateral, a local field potential is recorded in stratum radiatum of the CA1 region with field-effect transistors in the central part of the slice where the tissue is not damaged by the cutting process. After the impalement, the signal amplitude is small. Within an hour, it increases to a stable level around -2 mV as is recorded with a conventional micropipette electrode. The recovery indicates that the tissue is able to adapt to the impaled chip. Upon repeated impalements at the same position, the large signal is observed without delay. A profile of the transistor signal across the slice is due to the boundary conditions of a brain slice with both surfaces held near ground potential. The experiments with the TNC prototype are a basis for the development of silicon needle chips with a large multi-transistor array (MTA) for applications in brain-computer interfacing.

  2. Insulated solar storage tanks

    SciTech Connect

    Eldighidy, S.M. )

    1991-01-01

    This paper presents the theoretical and experimental investigation of an insulated parallelepiped, outdoor solar, water-filled storage tank of size 1 m {times} 0.5 m {times} 0.3 m, that is made from galvanized iron. The absorption coefficient of the insulating material has been determined. The effects of plastic covers and insulation thickness on the water temperature and the energy gained or lost by water are investigated. Moreover, the effects of insulation thickness on the temperature profiles of the insulating material are discussed. The results show that the absorption coefficient decreases as the insulation thickness increases. Also, it is found that the glass wool insulation of 2.5 cm thickness has the best results compared with the other thicknesses (5 cm, 7.5 cm, and 10 cm) as far as the water temperature and the energy gained by water are concerned.

  3. Cryogenic Insulation Systems

    NASA Technical Reports Server (NTRS)

    Augustynowicz, S. D.; Fesmire, J. E.; Wikstrom, J. P.

    1999-01-01

    The results of a comparative study of cryogenic insulation systems performed are presented. The key aspects of thermal insulation relative to cryogenic system design, testing, manufacturing, and maintenance are discussed. An overview of insulation development from an energy conservation perspective is given. Conventional insulation materials for cryogenic applications provide three levels of thermal conductivity. Actual thermal performance of standard multilayer insulation (MLI) is several times less than laboratory performance and often 10 times worse than ideal performance. The cost-effectiveness of the insulation system depends on thermal performance; flexibility and durability; ease of use in handling, installation, and maintenance; and overall cost including operations, maintenance, and life cycle. Results of comprehensive testing of both conventional and novel materials such as aerogel composites using cryostat boil-off methods are given. The development of efficient, robust cryogenic insulation systems that operate at a soft vacuum level is the primary focus of this paper.

  4. [Clinical experiences of RUAN's needling method for insomnia].

    PubMed

    Jiang, Ling-Zhen; Ruan, Bu-Qing

    2013-07-01

    The theoretical basis and needling techniques of RUAN's needling method in treatment of insomnia are introduced in this paper. Ruan's needling method follows the theory of traditional Chinese medicine and acupuncture, stresses the theory of taking brain as the marrow sea in treatment of insomnia acupuncture. The characteristics of his needling method are that emphasis on acupoints, including positioning accuracy and proper compatibility; think highly of needling method that combines with perpendicular needling, oblique needling, parallel needling, deep needling and shallow needling; emphasis on manipulation and identify qi under the needle to decide reinforcing or reducing method by arrival of qi, excess or deficiency. And the clinical observation of RUAN' s needling method on 30 cases of insomnia is attached. PMID:24032204

  5. Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid

    MedlinePlus

    ... Index A-Z Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid An ultrasound-guided thyroid biopsy ... Thyroid? What is Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid? During a fine needle aspiration ...

  6. Estimating needle-tissue interaction forces for hollow needles using fiber Bragg grating sensors

    NASA Astrophysics Data System (ADS)

    Kumar, Saurabh; Shrikanth, V.; Bharadwaj, Amrutur; Asokan, Sundarrajan; Bobji, M. S.

    2016-03-01

    Brachytherapy and neurological procedures can benefit from real-time estimation of needle-tissue interaction forces, specifically for robotic or robot-assisted procedures. Fiber Bragg Grating Sensors provide advantages of very small size and electromagnetic immunity for use in measurement of the forces directly at the needle tip. This has advantages compared to measurements at the needle shaft which require extensive models of the friction between needle and tissues with varying depth. This paper presents the measurement of tip forces for a hollow needle and compensation for bending when encountering regions of varying stiffness in phantoms with multiple layers prepared using Polydimethylsiloxane.

  7. Needle Exchange Programs and Drug Injection Behavior

    ERIC Educational Resources Information Center

    DeSimone, Jeff

    2005-01-01

    This study examines how drug injection and needle sharing propensities respond when a needle exchange program (NEP) is introduced into a city. I analyze 1989-1995 Drug Use Forecasting data on adult male arrestees from 24 large U.S. cities, in nine of which NEPs opened during the sample period. After controlling for cocaine and heroin prices, AIDS…

  8. 21 CFR 880.5580 - Acupuncture needle.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Acupuncture needle. 880.5580 Section 880.5580 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital and Personal Use Therapeutic Devices § 880.5580 Acupuncture needle....

  9. [Textual research on the fire needle and the fire needle therapy].

    PubMed

    Liu, T; Zhu, J P; Zhang, Q C

    2016-03-01

    There are different names of the fire needle therapy in the Huang di nei jing (Inner Canon of Huangdi) such as Zu-zhen (), Cui-zhen (,), Fan-zhen (), Huo-cui (), Cui (,,), Cuici ,), Fan zhen jie ci (). It is claimed that the lance needle, the round sharp needle and the long needle recorded in this Classic are puncturing tools for the fire needle therapy. In the Eastern Han Dynasty, Zhang Zhongjing expanded the indications for the fire needle therapy and Huo-zhen () firstly appeared in the Jin kui yu han jing(Classic of the Jade Box and Golden Chamber). The application of the fire needle therapy had been further expanded to a lot of internal and external disorders form the Wei-Jin-Southern and Northern Dynasties to the Ming and Qing Dynasties. There are more detailed records on the manipulation and the tools of the fire needle therapy during this period. In the 1970s, Huo zhen liao fa () was proposed and still in use today. However the Bai-zhen (plain needle) in ancient literature is equal to the filiform needle and should not be regarded as the former name of the fire needle. PMID:27255194

  10. A comparison of needle bending models.

    PubMed

    Dehghan, Ehsan; Goksel, Orcun; Salcudean, Septimiu E

    2006-01-01

    Modeling the deflection of flexible needles is an essential part of needle insertion simulation and path planning. In this paper, three models are compared in terms of accuracy in simulating the bending of a prostate brachytherapy needle. The first two utilize the finite element method, one using geometric non-linearity and triangular plane elements, the other using non-linear beam elements. The third model uses angular springs to model cantilever deflection. The simulations are compared with the experimental bent needle configurations. The models are assessed in terms of geometric conformity using independently identified and pre-identified model parameters. The results show that the angular spring model, which is also the simplest, simulates the needle more accurately than the others. PMID:17354904

  11. Laser needle guide for the sonic flashlight.

    PubMed

    Wang, David; Wu, Bing; Stetten, George

    2005-01-01

    We have extended the real-time tomographic reflection display of the Sonic Flashlight to a laser guidance system that aims to improve safety and accuracy of needle insertion, especially for deep procedures. This guidance system is fundamentally different from others currently available. Two low-intensity lasers are mounted on opposite sides of a needle aimed parallel to the needle. The needle is placed against a notch in the Sonic Flashlight mirror such that the laser beams reflect off the mirror to create bright red spots on the flat panel display. Due to diffuse reflection from these spots, the virtual image created by the flat panel display contains the spots, identifying the projected destination of the needle at its actual location in the tissue. We have implemented our design and validated its performance, identifying several areas for potential improvement. PMID:16685901

  12. Radiofrequency Cauterization with Biopsy Introducer Needle

    PubMed Central

    Pritchard, William F.; Wray-Cahen, Diane; Karanian, John W.; Hilbert, Stephen; Wood, Bradford J.

    2014-01-01

    PURPOSE The principal risks of needle biopsy are hemorrhage and implantation of tumor cells in the needle tract. This study compared hemorrhage after liver and kidney biopsy with and without radiofrequency (RF) ablation of the needle tract. MATERIALS AND METHODS Biopsies of liver and kidney were performed in swine through introducer needles modified to allow RF ablation with the distal 2 cm of the needle. After each biopsy, randomization determined whether the site was to undergo RF ablation during withdrawal of the introducer needle. Temperature was measured with a thermistor stylet near the needle tip, with a target temperature of 70°C–100°C with RF ablation. Blood loss was measured as grams of blood absorbed in gauze at the puncture site for 2 minutes after needle withdrawal. Selected specimens were cut for gross examination. RESULTS RF ablation reduced bleeding compared with absence of RF ablation in liver and kidney (P < .01), with mean blood loss reduced 63% and 97%, respectively. Mean amounts of blood loss (±SD) in the liver in the RF and no-RF groups were 2.03 g ± 4.03 (CI, 0.53–3.54 g) and 5.50 g ± 5.58 (CI, 3.33–7.66 g), respectively. Mean amounts of blood loss in the kidney in the RF and no-RF groups were 0.26 g ± 0.32 (CI, −0.01 to 0.53 g) and 8.79 g ± 7.72 (CI, 2.34–15.24 g), respectively. With RF ablation, thermal coagulation of the tissue surrounding the needle tract was observed. CONCLUSION RF ablation of needle biopsy tracts reduced hemorrhage after biopsy in the liver and kidney and may reduce complications of hemorrhage as well as implantation of tumor cells in the tract. PMID:14963187

  13. Apical pressures developed by needles for canal irrigation.

    PubMed

    Bradford, C E; Eleazer, P D; Downs, K E; Scheetz, J P

    2002-04-01

    Drying instrumented canals with pressurized air may result in patient morbidity or even fatality. Low pressure and side vent needles have been suggested to lessen the danger. This study observed apical pressures from different needles inserted deeply into small round and ovoid canals as instrumentation progressed. Low-pressure (5 psi) air was injected through the needles, and apical pressures were recorded after each instrument. Pressures varied greatly within each test group. Generalities that can be drawn are that binding the needle within the canal gives higher pressures than with the needle slightly short of binding and that pressures were higher with apexes instrumented to size 30 and higher. With the needle tightly bound, neither needle size, needle design, nor canal shape resulted in statistically significant mean pressure differences. With the needle slightly withdrawn, larger bore needles gave higher pressures than small diameter needles. Caution is advised with the clinical use of pressurized air in the drying of root canals. PMID:12043877

  14. Multilayer Insulation Material Guidelines

    NASA Technical Reports Server (NTRS)

    Finckenor, M. M.; Dooling, D.

    1999-01-01

    Multilayer Insulation Material Guidelines provides data on multilayer insulation materials used by previous spacecraft such as Spacelab and the Long-Duration Exposure Facility and outlines other concerns. The data presented in the document are presented for information only. They can be used as guidelines for multilayer insulation design for future spacecraft provided the thermal requirements of each new design and the environmental effects on these materials are taken into account.

  15. Composite Flexible Blanket Insulation

    NASA Technical Reports Server (NTRS)

    Kourtides, Demetrius A. (Inventor); Pitts, William C. (Inventor); Goldstein, Howard E. (Inventor); Sawko, Paul M. (Inventor)

    1991-01-01

    Composite flexible multilayer insulation systems (MLI) were evaluated for thermal performance and compared with the currently used fibrous silica (baseline) insulation system. The systems described are multilayer insulations consisting of alternating layers of metal foil and scrim ceramic cloth or vacuum metallized polymeric films quilted together using ceramic thread. A silicon carbide thread for use in the quilting and the method of making it are also described. These systems are useful in providing lightweight insulation for a variety of uses, particularly on the surface of aerospace vehicles subject to very high temperatures during flight.

  16. Insulated waterproof drainage material

    SciTech Connect

    Tarko, P.L.

    1988-03-15

    An insulative waterproof drainage material is described comprising: a sheet of rigid material having hills and valleys therein to define a core having opposed surfaces; permeable fabric material attached to one of the opposed surfaces; and a layer of thermally insulative material on the other of the opposed surfaces. The insulative material has first surface covering the hills and valleys and a second surface oppositely disposed from the first surface defining an outer surface. The outer surface is spaced a preselected distance D from the hills of the core. The pre-selected distance D define an insulative material thickness corresponding to a pre-selected thermal value.

  17. Loose-fill insulations

    SciTech Connect

    1995-05-01

    Whether you are increasing the insulation levels in your current home or selecting insulation for a new home, choosing the right insulation material can be challenging. Fibrous loose-fill insulations such as cellulose, fiberglass, and rock wool are options you may wish to consider. This publication will introduce you to these materials--what they are, how they are applied, how they compare with each other, and other considerations regarding their use--so that you can decide whether loose fills are right for your home.

  18. Alternator insulation evaluation tests

    NASA Technical Reports Server (NTRS)

    Penn, W. B.; Schaefer, R. F.; Balke, R. L.

    1972-01-01

    Tests were conducted to predict the remaining electrical insulation life of a 60 KW homopolar inductor alternator following completion of NASA turbo-alternator endurance tests for SNAP-8 space electrical power systems application. The insulation quality was established for two alternators following completion of these tests. A step-temperature aging test procedure was developed for insulation life prediction and applied to one of the two alternators. Armature winding insulation life of over 80,000 hours for an average winding temperature of 248 degrees C was predicted using the developed procedure.

  19. Federal funding for needle exchange programs.

    PubMed

    Clark, Peter A; Fadus, Matthew

    2010-01-01

    The HIV/AIDS pandemic has affected millions across the globe. The sharing of needles, for reasons of economy or social relations, has become the most common mode of HIV transmission among injection drug users. Needle exchange programs, which provide many services in addition to the exchange of clean needles for contaminated needles, have proven effective in reducing HIV rates among injection drug users in their communities. Although these programs have proven to be one of the most effective strategies in the efforts to reduce HIV rates, there has been a federal ban on the use of federal money for needle exchange programs since 1989. This ban was introduced by Congress in accordance with the drug war ideology, a narrow and elusive plan to completely eradicate drug use in the United States. Although there are a significant number of government reports supporting needle exchange programs, including support from the CDC, American Medical Association, the National Institutes of Health, it appears as If public health and the lives of others have become a secondary concern to strong federal policy on eradicating drug use. Lifting the federal ban would save the country millions of lives and billions of dollars in healthcare costs. Needle exchange programs should be an integral part of HIV prevention strategy, and are ethically imperative as well, restoring human dignity to the clients that so often need it.
    PMID:20037499

  20. Comparison of curcumin with intralesional steroid injections in Oral Submucous Fibrosis – A randomized, open-label interventional study

    PubMed Central

    Yadav, Monu; Aravinda, K.; Saxena, Vasu S.; Srinivas, K.; Ratnakar, P.; Gupta, Jyothi; Sachdev, Arti Saluja; Shivhare, Peeyush

    2014-01-01

    Introduction Oral Submucous Fibrosis (OSMF) is precancerous condition caused by areca nut chewing characterized by restricted mouth opening, burning sensation and stiffness & blanching of oral mucosa. Complete regression of the condition had not been achieved in all cases with any of the present treatment regimens. Curcumin is (diferuloylmethane), a yellow pigment in curry powder, exhibits anti-oxidant, anti-inflammatory, and pro-apoptotic activities. Hence an interventional study was undertaken to establish the efficacy of curcumin in OSMF patients. Settings & design A randomized open label, interventional study was conducted in forty patients with clinically and histologically proven Oral Submucous Fibrosis. Materials & methods Forty patients with clinically and histologically proven Oral Submucous Fibrosis were selected for the study and were randomly divided into 2 groups. The first group was treated with weekly intralesional injection of 4 mg Dexamethasone & 1500 I.U Hyaluronidase and the second group by oral administration of two Curcumin tablets (Turmix 300 mg) per day for 3 months each. Improvement of burning sensation, interincisal distance and tongue protrusion was evaluated on a weekly basis. Results Burning sensation improved in both the groups from early to late stages. Complete resolution of burning sensation was noted with turmix. The mean increase in interincisal distance was 3.13 mm and 1.25 mm respectively in groups 1 &2. The interincisal distance improved in both the groups, with significant results at the end of first month. Tongue protrusion showed greater recovery at the end of 1st month in group 1 when compared with group 2. Conclusion Turmix is beneficial and effective in reducing burning sensation in early OSMF patients. PMID:25737939

  1. Intralesional Injection of Mitomycin C at Transurethral Incision of Bladder Neck Contracture May Offer Limited Benefit: TURNS Study Group

    PubMed Central

    Redshaw, Jeffrey D.; Broghammer, Joshua A.; Smith, Thomas G.; Voelzke, Bryan B.; Erickson, Bradley A.; McClung, Christopher D.; Elliott, Sean P.; Alsikafi, Nejd F.; Presson, Angela P.; Aberger, Michael E.; Craig, James R.; Brant, William O.; Myers, Jeremy B.

    2015-01-01

    Purpose Injection of mitomycin C may increase the success of transurethral incision of the bladder neck for the treatment of bladder neck contracture. We evaluated the efficacy of mitomycin C injection across multiple institutions. Materials and Methods Data on all patients who underwent transurethral incision of the bladder neck with mitomycin C from 2009 to 2014 were retrospectively reviewed from 6 centers in the TURNS. Patients with at least 3 months of cystoscopic followup were included in the analysis. Results A total of 66 patients underwent transurethral incision of the bladder neck with mitomycin C and 55 meeting the study inclusion criteria were analyzed. Mean ± SD patient age was 64 ± 7.6 years. Dilation or prior transurethral incision of the bladder neck failed in 80% (44 of 55) of patients. Overall 58% (32 of 55) of patients achieved resolution of bladder neck contracture after 1 transurethral incision of the bladder neck with mitomycin C at a median followup of 9.2 months (IQR 11.7). There were 23 patients who had recurrence at a median of 3.7 months (IQR 4.2), 15 who underwent repeat transurethral incision of the bladder neck with mitomycin C and 9 of 15 (60%) who were free of another recurrence at a median of 8.6 months (IQR 8.8), for an overall success rate of 75% (41 of 55). Incision with electrocautery (Collins knife) was predictive of success compared with cold knife incision (63% vs 50%, p=0.03). Four patients experienced serious adverse events related to mitomycin C and 3 needed or are planning cystectomy. Conclusions The efficacy of intralesional injection of mitomycin C at transurethral incision of the bladder neck was lower than previously reported and was associated with a 7% rate of serious adverse events. PMID:25200807

  2. Intralesional hemorrhage and thrombosis without rupture in a pure spinal epidural cavernous angioma: a rare cause of acute lumbal radiculopathy.

    PubMed

    Floeth, Frank; Riemenschneider, Markus; Herdmann, Jörg

    2010-07-01

    Pure spinal epidural cavernous angiomas are extremely rare lesions, and their normal shape is that of a fusiform mass in the dorsal aspects of the spinal canal. We report a case of a lumbo-sacral epidural cavernous vascular malformation presenting with acute onset of right-sided S1 radiculopathy. Clinical aspects, imaging, intraoperative findings, and histology are demonstrated. The patient, a 27-year-old man presented with acute onset of pain, paraesthesia, and numbness within the right leg corresponding to the S1 segment. An acute lumbosacral disc herniation was suspected, but MRI revealed a cystic lesion with the shape of a balloon, a fluid level and a thickened contrast-enhancing wall. Intraoperatively, a purple-blue tumor with fibrous adhesions was located between the right S1 and S2 nerve roots. Macroscopically, no signs of epidural bleedings could be denoted. After coagulation of a reticular venous feeder network and dissection of the adhesions the rubber ball-like lesion was resected in total. Histology revealed a prominent venous vessel with a pathologically thickened, amuscular wall surrounded by smaller, hyalinized, venous vessels arranged in a back-to-back position typical for the diagnosis of a cavernous angioma. Lumina were partially occluded by thrombi. The surrounding fibrotic tissue showed signs of recurrent bleedings. There was no obvious mass hemorrhage into the surrounding tissue. In this unique case, the pathologic mechanism was not the usual rupture of the cavernous angioma with subsequent intraspinal hemorrhage, but acute mass effect by intralesional bleedings and thrombosis with subsequent increase of volume leading to nerve root compression. Thus, even without a sudden intraspinal hemorrhage a spinal cavernous malformation can cause acute symptoms identical to the clinical features of a soft disc herniation. PMID:20213297

  3. Preparation of Graphene-Modified Acupuncture Needle and Its Application in Detecting Neurotransmitters

    PubMed Central

    Tang, Lina; Du, Danxin; Yang, Fan; Liang, Zhong; Ning, Yong; Wang, Hua; Zhang, Guo-Jun

    2015-01-01

    We report a unique nanosensing platform by combining modern nanotechnology with traditional acupuncture needle to prepare graphene-modified acupuncture needle (G-AN), and using it for sensitive detection of neurotransmitters via electrochemistry. An electrochemical deposition method was employed to deposit Au nanoparticles (AuNPs) on the tip surface of the traditional acupuncture needle, while the other part of the needle was coated with insulation paste. Subsequently, the G-AN was obtained by cyclic voltammetry reduction of a graphene oxide solution on the surface of the AuNPs. To investigate the sensing property of the G-AN, pH dependence was measured by recording the open circuit potential in the various pH buffer solutions ranging from 2.0 to 10.0. What’s more, the G-AN was further used for detection of dopamine (DA) with a limit of detection of 0.24 μM. This novel G-AN exhibited a good sensitivity and selectivity, and could realize direct detection of DA in human serum. PMID:26112773

  4. Preparation of Graphene-Modified Acupuncture Needle and Its Application in Detecting Neurotransmitters

    NASA Astrophysics Data System (ADS)

    Tang, Lina; Du, Danxin; Yang, Fan; Liang, Zhong; Ning, Yong; Wang, Hua; Zhang, Guo-Jun

    2015-06-01

    We report a unique nanosensing platform by combining modern nanotechnology with traditional acupuncture needle to prepare graphene-modified acupuncture needle (G-AN), and using it for sensitive detection of neurotransmitters via electrochemistry. An electrochemical deposition method was employed to deposit Au nanoparticles (AuNPs) on the tip surface of the traditional acupuncture needle, while the other part of the needle was coated with insulation paste. Subsequently, the G-AN was obtained by cyclic voltammetry reduction of a graphene oxide solution on the surface of the AuNPs. To investigate the sensing property of the G-AN, pH dependence was measured by recording the open circuit potential in the various pH buffer solutions ranging from 2.0 to 10.0. What’s more, the G-AN was further used for detection of dopamine (DA) with a limit of detection of 0.24 μM. This novel G-AN exhibited a good sensitivity and selectivity, and could realize direct detection of DA in human serum.

  5. Fine-needle aspiration by vacuum tubes.

    PubMed

    Holmquist, N D

    1989-07-01

    Fine-needle aspiration of subcutaneous masses, accepted in many parts of Europe and the Americas as a routine diagnostic technique, employs a syringe holder to facilitate the creation of a vacuum to withdraw cells. This investigation demonstrates that a vacuum tube used in venipuncture can be used to supply the negative pressure to suck cells into the needle. This apparatus is more readily available than a syringe holder in hospitals and clinics, and particularly provides the operator with a more dexterous approach to the mass because the fingers holding the needle can be much closer to the mass being immobilized by the other hand. PMID:2750713

  6. Gas insulated transmission line with insulators having field controlling recesses

    DOEpatents

    Cookson, Alan H.; Pederson, Bjorn O.

    1984-01-01

    A gas insulated transmission line having a novel insulator for supporting an inner conductor concentrically within an outer sheath. The insulator has a recess contiguous with the periphery of one of the outer and inner conductors. The recess is disposed to a depth equal to an optimum gap for the dielectric insulating fluid used for the high voltage insulation or alternately disposed to a large depth so as to reduce the field at the critical conductor/insulator interface.

  7. Optimal needle design for minimal insertion force and bevel length.

    PubMed

    Wang, Yancheng; Chen, Roland K; Tai, Bruce L; McLaughlin, Patrick W; Shih, Albert J

    2014-09-01

    This research presents a methodology for optimal design of the needle geometry to minimize the insertion force and bevel length based on mathematical models of cutting edge inclination and rake angles and the insertion force. In brachytherapy, the needle with lower insertion force typically is easier for guidance and has less deflection. In this study, the needle with lancet point (denoted as lancet needle) is applied to demonstrate the model-based optimization for needle design. Mathematical models to calculate the bevel length and inclination and rake angles for lancet needle are presented. A needle insertion force model is developed to predict the insertion force for lancet needle. The genetic algorithm is utilized to optimize the needle geometry for two cases. One is to minimize the needle insertion force. Using the geometry of a commercial lancet needle as the baseline, the optimized needle has 11% lower insertion force with the same bevel length. The other case is to minimize the bevel length under the same needle insertion force. The optimized design can reduce the bevel length by 46%. Both optimized needle designs were validated experimentally in ex vivo porcine liver needle insertion tests and demonstrated the methodology of the model-based optimal needle design. PMID:24957487

  8. Pine needle abortion biomarker detected in bovine fetal fluids

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Pine needle abortion is a naturally occurring condition in free-range cattle caused by the consumption of pine needles from select species of cypress, juniper, pine, and spruce trees. Confirmatory diagnosis of pine needle abortion has previously relied on a combined case history of pine needle cons...

  9. Insulation Fact Sheet.

    ERIC Educational Resources Information Center

    Conservation and Renewable Energy Inquiry and Referral Service (DOE), Silver Spring, MD.

    Heating and cooling account for 50-70% of the energy consumed in the average American home. Heating water accounts for another 20%. A poorly insulated home loses much of this energy, causing drafty rooms and high energy bills. This fact sheet discusses how to determine if your home needs more insulation, the additional thermal resistance (called…

  10. Mineral Wool Insulation Binders

    NASA Astrophysics Data System (ADS)

    Kowatsch, Stefan

    Mineral wool is considered the best known insulation type among the wide variety of insulation materials. There are three types of mineral wool, and these consist of glass, stone (rock), and slag wool. The overall manufacturing processes, along with features such as specifications and characteristics for each of these types, as well as the role of the binder within the process are described.

  11. Thermal insulation blanket material

    NASA Technical Reports Server (NTRS)

    Pusch, R. H.

    1982-01-01

    A study was conducted to provide a tailorable advanced blanket insulation based on a woven design having an integrally woven core structure. A highly pure quartz yarn was selected for weaving and the cells formed were filled with a microquartz felt insulation.

  12. Sliding Mode Control of Steerable Needles

    PubMed Central

    Rucker, D. Caleb; Das, Jadav; Gilbert, Hunter B.; Swaney, Philip J.; Miga, Michael I.; Sarkar, Nilanjan; Webster, Robert J.

    2014-01-01

    Steerable needles can potentially increase the accuracy of needle-based diagnosis and therapy delivery, provided they can be adequately controlled based on medical image information. We propose a novel sliding mode control law that can be used to deliver the tip of a flexible asymmetric-tipped needle to a desired point, or to track a desired trajectory within tissue. The proposed control strategy requires no a priori knowledge of model parameters, has bounded input speeds, and requires little computational resources. We show that if the standard nonholonomic model for tip-steered needles holds, then the control law will converge to desired targets in a reachable workspace, within a tolerance that can be defined by the control parameters. Experimental results validate the control law for target points and trajectory following in phantom tissue and ex vivo liver. Experiments with targets that move during insertion illustrate robustness to disturbances caused by tissue deformation. PMID:25400527

  13. Science off the Sphere: Knitting Needles

    NASA Video Gallery

    International Space Station Expedition 30 astronaut Don Pettit uses knitting needles and water droplets to demonstrate physics in space for 'Science off the Sphere.' Through a partnership between N...

  14. Demand for superpremium needle cokes on upswing

    SciTech Connect

    Acciarri, J.A.; Stockman, G.H. )

    1989-12-01

    The authors discuss how recent supply shortages of super-premium quality needle cokes, plus the expectation of increased shortfalls in the future, indicate that refiners should consider upgrading their operations to fill these demands. Calcined, super-premium needle cokes are currently selling for as much as $550/metric ton, fob producer, and increasing demand will continue the upward push of the past year. Needle coke, in its calcined form, is the major raw material in the manufacture of graphite electrodes. Used in steelmaking, graphite electrodes are the electrical conductors that supply the heat source, through arcing electrode column tips, to electric arc steel furnaces. Needle coke is commercially available in three grades - super premium, premium, and intermediate. Super premium is used to produce electrodes for the most severe electric arc furnace steelmaking applications, premium for electrodes destined to less severe operations, and intermediate for even less critical needs.

  15. Sliding Mode Control of Steerable Needles.

    PubMed

    Rucker, D Caleb; Das, Jadav; Gilbert, Hunter B; Swaney, Philip J; Miga, Michael I; Sarkar, Nilanjan; Webster, Robert J

    2013-10-01

    Steerable needles can potentially increase the accuracy of needle-based diagnosis and therapy delivery, provided they can be adequately controlled based on medical image information. We propose a novel sliding mode control law that can be used to deliver the tip of a flexible asymmetric-tipped needle to a desired point, or to track a desired trajectory within tissue. The proposed control strategy requires no a priori knowledge of model parameters, has bounded input speeds, and requires little computational resources. We show that if the standard nonholonomic model for tip-steered needles holds, then the control law will converge to desired targets in a reachable workspace, within a tolerance that can be defined by the control parameters. Experimental results validate the control law for target points and trajectory following in phantom tissue and ex vivo liver. Experiments with targets that move during insertion illustrate robustness to disturbances caused by tissue deformation. PMID:25400527

  16. Dynamics insulation systems

    NASA Astrophysics Data System (ADS)

    Chen, W. E. W.; Hepler, W. A.; Yuan, S. W. K.; Frederking, T. H. K.

    1985-10-01

    Advanced dynamic insulation systems were analyzed from a thermodynamic point of view. A particular performance measure is proposed in order to characterize various insulations in a unique manner. This measure is related to a base quantity, the refrigeration power ratio. The latter is the minimum refrigeration power, for a particular dynamic insulation limit, to the actual reliquefaction power associated with cryoliquid boiloff. This ratio serves as reference quantity which is approximately constant for a specific ductless insulation at a chosen normal boiling point. Each real container with support structure, vent tube, and other transverse components requires a larger refrigeration power. The ratio of the actual experimental power to the theoretical value of the support-less system is a suitable measure of the entire insulation performance as far as parasitic heat leakage is concerned. The present characterization is illustrated using simple thermodynamic system examples including experiments with liquid nitrogen. Numerical values are presented and a comparison with liquid helium is given.

  17. Topological Kondo Insulators

    NASA Astrophysics Data System (ADS)

    Dzero, Maxim; Xia, Jing; Galitski, Victor; Coleman, Piers

    2016-03-01

    This article reviews recent theoretical and experimental work on a new class of topological material -- topological Kondo insulators, which develop through the interplay of strong correlations and spin-orbit interactions. The history of Kondo insulators is reviewed along with the theoretical models used to describe these heavy fermion compounds. The Fu-Kane method of topological classification of insulators is used to show that hybridization between the conduction electrons and localized f electrons in these systems gives rise to interaction-induced topological insulating behavior. Finally, some recent experimental results are discussed, which appear to confirm the theoretical prediction of the topological insulating behavior in samarium hexaboride, where the long-standing puzzle of the residual low-temperature conductivity has been shown to originate from robust surface states.

  18. Breakdown of organic insulators

    NASA Technical Reports Server (NTRS)

    Cuddihy, E. F.

    1983-01-01

    Solar cells and their associated electrical interconnects and leads were encapsulated in transparent elastomeric materials. Their purpose in a photovoltaic module, one of the most important for these elastomeric encapsulation materials, is to function as electrical insulation. This includes internal insulation between adjacent solar cells, between other encapsulated electrical parts, and between the total internal electrical circuitry and external metal frames, grounded areas, and module surfaces. Catastrophic electrical breakdown of the encapsulant insulation materials or electrical current through these materials or module edges to external locations can lead to module failure and can create hazards to humans. Electrical insulation stability, advanced elastomeric encapsulation materials are developed which are intended to be intrinsically free of in-situ ionic impurities, have ultralow water absorption, be weather-stable (UV, oxygen), and have high mechanical flexibility. Efforts to develop a method of assessing the life potential of organic insulation materials in photovoltaic modules are described.

  19. Percutaneous needle biopsy of the irradiated skeleton

    SciTech Connect

    Edeiken, B.; deSantos, L.A.

    1983-03-01

    Percutaneous needle biopsy was performed in 20 patients who had radiologic abnormalities after irradiation of the skeleton. The biopsies were performed to determine the nature of the bone changes and to differentiate radiation necrosis from metastases or local tumor extension. Eleven patients had tumors, two of which were radiation-induced sarcomas; nine patients did not show evidence of tumor. One patient had osteomyelitis rather than the suspected tumor. The value of percutaneous needle biopsy in the postirradiated skeleton is discussed.

  20. Dry needling versus acupuncture: the ongoing debate.

    PubMed

    Zhou, Kehua; Ma, Yan; Brogan, Michael S

    2015-12-01

    Although Western medical acupuncture (WMA) is commonly practised in the UK, a particular approach called dry needling (DN) is becoming increasingly popular in other countries. The legitimacy of the use of DN by conventional non-physician healthcare professionals is questioned by acupuncturists. This article describes the ongoing debate over the practice of DN between physical therapists and acupuncturists, with a particular emphasis on the USA. DN and acupuncture share many similarities but may differ in certain aspects. Currently, little information is available from the literature regarding the relationship between the two needling techniques. Through reviewing their origins, theory, and practice, we found that DN and acupuncture overlap in terms of needling technique with solid filiform needles as well as some fundamental theories. Both WMA and DN are based on modern biomedical understandings of the human body, although DN arguably represents only one subcategory of WMA. The increasing volume of research into needling therapy explains its growing popularity in the musculoskeletal field including sports medicine. To resolve the debate over DN practice, we call for the establishment of a regulatory body to accredit DN courses and a formal, comprehensive educational component and training for healthcare professionals who are not physicians or acupuncturists. Because of the close relationship between DN and acupuncture, collaboration rather than dispute between acupuncturists and other healthcare professionals should be encouraged with respect to education, research, and practice for the benefit of patients with musculoskeletal conditions who require needling therapy. PMID:26546163

  1. Study on the characteristic decomposition components of air-insulated switchgear cabinet under partial discharge

    NASA Astrophysics Data System (ADS)

    Gui, Yingang; Zhang, Xiaoxing; Zhang, Ying; Qiu, Yinjun; Chen, Lincong

    2016-07-01

    Air-insulated switchgear cabinet plays a critical role in entire power transmission and distribution system. Its stability directly affects the operational reliability of the power system. And the on-line gas detection method, which evaluates the insulation status of insulation equipment by detecting the decomposition components of filled air in cabinet, becomes an innovative way to ensure the running stability of air-insulated switchgear cabinet. In order to study the characteristic gas types and production regularity of decomposition components under partial discharge, three insulation defects: needle-plate, air-gap and impurity defect are proposed to simulate the insulation defects under partial discharge in air-insulated switchgear cabinet. Firstly, the generation pathways and mechanism of composition components are discussed. Then CO and NO2 are selected as the characteristic decomposition components to characterize the partial discharge due to their high concentration and chemical stability. Based on the different change regularity of CO and NO2 concentration under different insulation defect, it provides an effective way to evaluate and predict the insulation defect type and severity in the field.

  2. Cooper Pair Insulators

    NASA Astrophysics Data System (ADS)

    Valles, James

    One of the recent advances in the field of the Superconductor to Insulator Transition (SIT) has been the discovery and characterization of the Cooper Pair Insulator phase. This bosonic insulator, which consists of localized Cooper pairs, exhibits activated transport and a giant magneto-resistance peak. These features differ markedly from the weakly localized transport that emerges as pairs break at a ``fermionic'' SIT. I will describe how our experiments on films nano-patterned with a nearly triangular array of holes have enabled us to 1) distinguish bosonic insulators from fermionic insulators, 2) show that Cooper pairs, rather than quasi-particles dominate the transport in the Cooper Pair insulator phase, 3) demonstrate that very weak, sub nano-meter thickness inhomogeneities control whether a bosonic or fermionic insulator forms at an SIT and 4) reveal that Cooper pairs disintegrate rather than becoming more tightly bound deep in the localized phase. We have also developed a method, using a magnetic field, to tune flux disorder reversibly in these films. I will present our latest results on the influence of magnetic flux disorder and random gauge fields on phenomena near bosonic SITs. This work was performed in collaboration with M. D. Stewart, Jr., Hung Q. Nguyen, Shawna M. Hollen, Jimmy Joy, Xue Zhang, Gustavo Fernandez, Jeffrey Shainline and Jimmy Xu. It was supported by NSF Grants DMR 1307290 and DMR-0907357.

  3. Intralesional administration of epidermal growth factor-based formulation (Heberprot-P) in chronic diabetic foot ulcer: treatment up to complete wound closure.

    PubMed

    Fernández-Montequín, José I; Betancourt, Blas Y; Leyva-Gonzalez, Gisselle; Mola, Ernesto L; Galán-Naranjo, Katia; Ramírez-Navas, Mayte; Bermúdez-Rojas, Sergio; Rosales, Felix; García-Iglesias, Elizeth; Berlanga-Acosta, Jorge; Silva-Rodriguez, Ricardo; Garcia-Siverio, Marianela; Martinez, Luis H

    2009-02-01

    Previous studies have shown that an epidermal growth factor-based formulation (Heberprot-P) can enhance granulation of high-grade diabetic foot ulcers (DFU). The aim of this study was to explore the clinical effects of this administration up to complete wound closure. A pilot study in 20 diabetic patients with full-thickness lower extremity ulcers of more than 4 weeks of evolution was performed. Mean ulcer size was 16.3 +/- 21.3 cm(2). Intralesional injections of 75 microg of Heberprot-P three times per week were given up to complete wound healing. Full granulation response was achieved in all 20 patients in 23.6 +/- 3.8 days. Complete wound closure was obtained in 17 (85%) cases in 44.3 +/- 8.9 days. Amputation was not necessary in any case and only one relapse was notified. The most frequent adverse events were tremors, chills, pain and odour at site of administration and local infection. The therapeutic scheme of intralesional Heberprot-P administration up to complete closure can be safe and suitable to improve the therapeutic goal in terms of healing of chronic DFU. PMID:19291119

  4. Efficacy of Optical Internal Urethrotomy and Intralesional Injection of Vatsala-Santosh PGI Tri-Inject (Triamcinolone, Mitomycin C, and Hyaluronidase) in the Treatment of Anterior Urethral Stricture

    PubMed Central

    Singh, Shrawan Kumar; Mandal, Arup Kumar

    2014-01-01

    Purpose. To study the efficacy of optical internal urethrotomy with intralesional injection of Vatsala-Santosh PGI tri-inject (triamcinolone, mitomycin C, and hyaluronidase) in the treatment of anterior urethral stricture. Material and Methods. A total of 103 patients with symptomatic anterior urethral stricture were evaluated on the basis of clinical history, physical examination, uroflowmetry, and retrograde urethrogram preoperatively. All patients were treated with optical internal urethrotomy followed by injection of tri-inject at the urethrotomy site. Tri-inject was prepared by diluting the combination of triamcinolone 40 mg, mitomycin C 2 mg, and hyaluronidase 3000 in 5–10 mL of saline according to length of stricture. An indwelling 18 Fr silicone catheter was left in place for a period of 7–21 days. All patients were followed up for 6–18 months postoperatively on the basis of history, uroflowmetry, and, if required, retrograde urethrogram and micturating urethrogram every 3 months. Results. The overall recurrence rate after first OIU is 19.4% (20 out of 103 patients), that is, a success rate of 80.6%. Overall recurrence rate after second procedure was 5.8% (6 out of 103 patients), that is, a success rate of 94.2%. Conclusion. Optical internal urethrotomy with intralesional injection of Vatsala-Santosh PGI tri-inject (triamcinolone, mitomycin C, and hyaluronidase) is a safe and effective minimally invasive therapeutic modality for short segment anterior urethral strictures. PMID:25349604

  5. Radiofrequency thermal ablation of breast tumors combined with intralesional administration of IL-7 and IL-15 augments anti-tumor immune responses and inhibits tumor development and metastasis

    PubMed Central

    Habibi, Mehran; Kmieciak, Maciej; Graham, Laura; Morales, Johanna K; Bear, Harry D; Manjili, Masoud H

    2008-01-01

    Tumor development or recurrence is always a matter of concern following radiofrequency thermal ablation (RFA) of tumors. To determine whether combining RFA with immunologically active cytokines might induce tumor-specific immune responses against mammary carcinoma and inhibit tumor development or metastasis, we evaluated intralesional injection of IL-7 and IL-15 in RFA-treated murine tumors. We used two different breast carcinoma models: neu-overexpressing mouse mammary carcinoma (MMC) in FVBN202 transgenic mouse and 4T1 tumors in Balb/c mouse. MMC tend to relapse even in the presence of neu-specific immune responses, and 4T1 is a weakly immunogenic, aggressive and highly metastatic transplantable tumor. In vivo growth of both of these tumors is also associated with increased numbers of CD11b+Gr1+ myeloid-derived suppressor cells (MDSC). We showed for the first time that unlike RFA alone, RFA combined with the administration of intralesional IL-7 and IL-15 (after RFA), induced immune responses to tumors, inhibited tumor development and lung metastasis, and reduced MDSC. PMID:18425677

  6. Cryogenic insulation development

    NASA Technical Reports Server (NTRS)

    Leonhard, K. E.

    1972-01-01

    Multilayer insulations for long term cryogenic storage are described. The development effort resulted in an insulation concept using lightweight radiation shields, separated by low conductive Dacron fiber tufts. The insulation is usually referred to as Superfloc. The fiber tufts are arranged in a triangular pattern and stand about .040 in. above the radiation shield base. Thermal and structural evaluation of Superfloc indicated that this material is a strong candidate for the development of high performance thermal protection systems because of its high strength, purge gas evacuation capability during boost, its density control and easy application to a tank.

  7. Building insulation technology: Kuwait

    SciTech Connect

    Ezz Al Din, M.A.

    1986-01-01

    Recommendations are reached through the use of a value analysis approach to adapt building insulation technology to Kuwait environment. The economical and technical aspects of using insulation influencing architectural and engineering decisions are presented. Research has confirmed that savings of 25% to 40% of electrical energy required in cooling and heating the building can be achieved by the proper use of insulating materials. Though the ideas of this study are tailored for Kuwait, yet it may be appropriate and applicable to many countries with hot climate.

  8. Insulation fact sheet

    SciTech Connect

    1997-08-01

    Electricity bills, oil bills, gas bills - all homeowners pay for one or more of these utilities, and wish they paid less. Often many of us do not really know how to control or reduce our utility bills. We resign ourselves to high bills because we think that is the price we have to pay for a comfortable home. We encourage our children to turn off the lights and appliances, but may not recognize the benefits of insulating the attic. This publication provides facts relative to home insulation. It discusses where to insulate, what products to use, the decision making process, installation options, and sources of additional information.

  9. Internal insulation system development

    NASA Technical Reports Server (NTRS)

    Gille, J. P.

    1973-01-01

    The development of an internal insulation system for cryogenic liquids is described. The insulation system is based on a gas layer concept in which capillary or surface tension effects are used to maintain a stable gas layer within a cellular core structure between the tank wall and the contained cryogen. In this work, a 1.8 meter diameter tank was insulated and tested with liquid hydrogen. Ability to withstand cycling of the aluminum tank wall to 450 K was a design and test condition.

  10. Microsphere Insulation Panels

    NASA Technical Reports Server (NTRS)

    Mohling, R.; Allen, M.; Baumgartner, R.

    2006-01-01

    Microsphere insulation panels (MIPs) have been developed as lightweight, longlasting replacements for the foam and vacuum-jacketed systems heretofore used for thermally insulating cryogenic vessels and transfer ducts. The microsphere core material of a typical MIP consists of hollow glass bubbles, which have a combination of advantageous mechanical, chemical, and thermal-insulation properties heretofore available only separately in different materials. In particular, a core filling of glass microspheres has high crush strength and low density, is noncombustible, and performs well in soft vacuum.

  11. Transbronchial needle aspiration with a new electromagnetically-tracked TBNA needle

    NASA Astrophysics Data System (ADS)

    Choi, Jae; Popa, Teo; Gruionu, Lucian

    2009-02-01

    Transbronchial needle aspiration (TBNA) is a common method used to collect tissue for diagnosis of different chest diseases and for staging lung cancer, but the procedure has technical limitations. These limitations are mostly related to the difficulty of accurately placing the biopsy needles into the target mass. Currently, pulmonologists plan TBNA by examining a number of Computed Tomography (CT) scan slices before the operation. Then, they manipulate the bronchoscope down the respiratory track and blindly direct the biopsy. Thus, the biopsy success rate is low. The diagnostic yield of TBNA is approximately 70 percent. To enhance the accuracy of TBNA, we developed a TBNA needle with a tip position that can be electromagnetically tracked. The needle was used to estimate the bronchoscope's tip position and enable the creation of corresponding virtual bronchoscopic images from a preoperative CT scan. The TBNA needle was made with a flexible catheter embedding Wang Transbronchial Histology Needle and a sensor tracked by electromagnetic field generator. We used Aurora system for electromagnetic tracking. We also constructed an image-guided research prototype system incorporating the needle and providing a user-friendly interface to assist the pulmonologist in targeting lesions. To test the feasibility of the accuracy of the newly developed electromagnetically-tracked needle, a phantom study was conducted in the interventional suite at Georgetown University Hospital. Five TBNA simulations with a custom-made phantom with a bronchial tree were performed. The experimental results show that our device has potential to enhance the accuracy of TBNA.

  12. Incidence and severity of Arcanobacterium pyogenes injection site abscesses with needle or needle-free injection.

    PubMed

    Gerlach, Bryce M; Houser, Terry A; Hollis, Larry C; Tokach, Michael D; Nietfeld, Jerome C; Higgins, James J; Anderson, Gary A; Goehring, Brandon L

    2012-12-01

    Nursery-age pigs (n=198) were used to evaluate the difference in abscess formation at needle-free jet and conventional needle-and-syringe injection sites. Needle-free jet injection was used to administer injections in the neck and ham on one side of the animal whereas needle-and-syringe was used for neck and ham injections on the opposite side. Immediately prior to injection, the injection site surfaces were contaminated with an inoculum of Arcanobacterium pyogenes. Each pig was humanely euthanized 27 or 28 days after injections. Histopathological results showed that needle-free jet injection was associated with more abscesses than needle-and-syringe injection at both neck (P=0.0625) and ham (P=0.0313) injection sites. Out of 792 injection sites, only 13 abscesses were observed, with 12 of those present at needle-free jet injection sites. Needle-free jet injection may increase the occurrence of injection site abscesses that necessitate carcass trimming at pork processing plants. PMID:22854129

  13. Composite flexible blanket insulation

    NASA Technical Reports Server (NTRS)

    Kourtides, Demetrius A. (Inventor); Lowe, David M. (Inventor)

    1994-01-01

    An improved composite flexible blanket insulation is presented comprising top silicon carbide having an interlock design, wherein the reflective shield is composed of single or double aluminized polyimide and wherein the polyimide film has a honeycomb pattern.

  14. Cryoresistive gas insulated line

    NASA Astrophysics Data System (ADS)

    Hidaka, K.; Matsumoto, S.; Kouno, T.

    An insulation strength of more than 16 kV mm -1 has been realized using nitrogen gas at 133 K and 0.4 MPa with the application of a.c. and impulse voltages. A cryoresistive gas insulated line (CRGIL) using nitrogen gas is proposed on the basis of the measured insulation strength. An efficient method for use of the cooling heat of liquefied natural gas is also proposed so that no refrigerator is required and the cost of cooling is reduced. The CRGIL has the advantages of having a large current carrying capacity, small power loss and small capacitance. Moreover, a given transmission capacity is achieved by a CRGIL whose rated voltage is about half that in a conventional gas insulated line.

  15. Cooper Pairs in Insulators?!

    ScienceCinema

    James Valles

    2010-01-08

    Nearly 50 years elapsed between the discovery of superconductivity and the emergence of the microscopic theory describing this zero resistance state. The explanation required a novel phase of matter in which conduction electrons joined in weakly bound pairs and condensed with other pairs into a single quantum state. Surprisingly, this Cooper pair formation has also been invoked to account for recently uncovered high-resistance or insulating phases of matter. To address this possibility, we have used nanotechnology to create an insulating system that we can probe directly for Cooper pairs. I will present the evidence that Cooper pairs exist and dominate the electrical transport in these insulators and I will discuss how these findings provide new insight into superconductor to insulator quantum phase transitions. 

  16. Insulator for laser housing

    DOEpatents

    Duncan, David B.

    1992-01-01

    The present invention provides a heat-resistant electrical insulator adapted for joining laser housing portions, which insulator comprises: an annulus; a channel in the annulus traversing the circumference and length of the housing; at least two ports, each communicating with the channel and an outer surface of the housing; and an attachment for securely attaching each end of the annulus to a laser housing member.

  17. Vacuum foil insulation system

    DOEpatents

    Hanson, John P.; Sabolcik, Rudolph E.; Svedberg, Robert C.

    1976-11-16

    In a multifoil thermal insulation package having a plurality of concentric cylindrical cups, means are provided for reducing heat loss from the penetration region which extends through the cups. At least one cup includes an integral skirt extending from one end of the cup to intersection with the penetration means. Assembly of the insulation package with the skirted cup is facilitated by splitting the cup to allow it to be opened up and fitted around the other cups during assembly.

  18. Insulator for laser housing

    DOEpatents

    Duncan, D.B.

    1992-12-29

    The present invention provides a heat-resistant electrical insulator adapted for joining laser housing portions, which insulator comprises: an annulus; a channel in the annulus traversing the circumference and length of the housing; at least two ports, each communicating with the channel and an outer surface of the housing; and an attachment for securely attaching each end of the annulus to a laser housing member. 3 figs.

  19. Optical Coherence Tomography in a Needle Format

    NASA Astrophysics Data System (ADS)

    Lorenser, Dirk; McLaughlin, Robert A.; Sampson, David D.

    In this chapter, we review the technology and applications of needle probes for optical coherence tomography (OCT). Needle probes are miniaturized fiber-optic probes that can be mounted inside hypodermic needles, allowing them to be inserted deep into the body during OCT imaging. This overcomes the very limited imaging depth of OCT of only 2-3 mm in biological tissue, enabling access to deep-tissue locations that are beyond the reach of free-space optical scan heads or catheters. This chapter provides an in-depth review of the current state-of-the art in needle probe technology, including optical design and fabrication, scan mechanisms (including three-dimensional scanning), and integration into OCT systems. It also provides an overview of emerging applications of this fascinating new imaging tool in areas such as cancer diagnosis, pulmonary imaging, imaging of the eye and imaging of the brain. Finally, two case studies are presented, illustrating needle-based OCT imaging in breast cancer and lungs.

  20. DIY guide-needle-assisted conjunctivodacryocystorhinostomy (CDCR).

    PubMed

    Paik, Ji-Sun; Kim, Su-Ah; Doh, Sang-Hee

    2013-01-01

    In this study, we introduce DIY guide-needle-assisted conjunctivodacryocystorhinostomy (CDCR), in which a guide needle helps in measuring the initial Jones tube length for insertion and reduces unnecessary handling for tube changes. Three CDCR procedures were conducted in which the length of the Jones tube was calculated using a 22-gauge DIY guide needle, and a prospective study of tube position change and migration, (a major cause of CDCR failure) was done. Wound healing was almost complete within 4 weeks postoperatively in the osteotomy site, but in cases of partial middle turbinectomy, a little more time was necessary. There was a slight change in Jones tube position in the nasal cavity compared with the expected position of original tube tip, but no tube migration from the caruncle fixation position had occurred by the final follow-up time. This guide-needle-assisted CDCR has multiple advantages, such as easy measurement of the proper initial tube size, utilization of the initial needle path, and easy replacement of tubes. Finally, this approach to CDCR can be readily applied because it uses materials ordinarily found in hospitals to create the devices needed for the procedure, so there is no additional cost. PMID:22526574

  1. Medically relevant ElectroNeedle technology development.

    SciTech Connect

    Schmidt, Carrie Frances; Thomas, Michael Loren; McClain, Jaime L.; Harper, Jason C.; Achyuthan, Komandoor E.; Ten Eyck, Gregory A.

    2008-11-01

    ElectroNeedles technology was developed as part of an earlier Grand Challenge effort on Bio-Micro Fuel Cell project. During this earlier work, the fabrication of the ElectroNeedles was accomplished along with proof-of-concept work on several electrochemically active analytes such as glucose, quinone and ferricyanide. Additionally, earlier work demonstrated technology potential in the field of immunosensors by specifically detecting Troponin, a cardiac biomarker. The current work focused upon fabrication process reproducibility of the ElectroNeedles and then using the devices to sensitively detect p-cresol, a biomarker for kidney failure or nephrotoxicity. Valuable lessons were learned regarding fabrication assurance and quality. The detection of p-cresol was accomplished by electrochemistry as well as using fluorescence to benchmark ElectroNeedles performance. Results from these studies will serve as a guide for the future fabrication processes involving ElectroNeedles as well as provide the groundwork necessary to expand technology applications. One paper has been accepted for publication acknowledging LDRD funding (K. E. Achyuthan et al, Comb. Chem. & HTS, 2008). We are exploring the scope for a second paper describing the applications potential of this technology.

  2. Wrapped Multilayer Insulation

    NASA Technical Reports Server (NTRS)

    Dye, Scott A.

    2015-01-01

    New NASA vehicles, such as Earth Departure Stage (EDS), Orion, landers, and orbiting fuel depots, need improved cryogenic propellant transfer and storage for long-duration missions. Current cryogen feed line multilayer insulation (MLI) performance is 10 times worse per area than tank MLI insulation. During each launch, cryogenic piping loses approximately 150,000 gallons (equivalent to $300,000) in boil-off during transfer, chill down, and ground hold. Quest Product Development Corp., teaming with Ball Aerospace, developed an innovative advanced insulation system, Wrapped MLI (wMLI), to provide improved thermal insulation for cryogenic feed lines. wMLI is high-performance multilayer insulation designed for cryogenic piping. It uses Quest's innovative discrete-spacer technology to control layer spacing/ density and reduce heat leak. The Phase I project successfully designed, built, and tested a wMLI prototype with a measured heat leak 3.6X lower than spiral-wrapped conventional MLI widely used for piping insulation. A wMLI prototype had a heat leak of 7.3 W/sq m, or 27 percent of the heat leak of conventional MLI (26.7 W/sq m). The Phase II project is further developing wMLI technology with custom, molded polymer spacers and advancing the product toward commercialization via a rigorous testing program, including developing advanced vacuuminsulated pipe for ground support equipment.

  3. Wrapped Multilayer Insulation

    NASA Technical Reports Server (NTRS)

    Dye, Scott A.

    2015-01-01

    New NASA vehicles, such as Earth Departure Stage (EDS), Orion, landers, and orbiting fuel depots, need improved cryogenic propellant transfer and storage for long-duration missions. Current cryogen feed line multilayer insulation (MLI) performance is 10 times worse per area than tank MLI insulation. During each launch, cryogenic piping loses approximately 150,000 gallons (equivalent to $300,000) in boil-off during transfer, chill down, and ground hold. Quest Product Development Corp., teaming with Ball Aerospace, developed an innovative advanced insulation system, Wrapped MLI (wMLI), to provide improved thermal insulation for cryogenic feed lines. wMLI is high-performance multilayer insulation designed for cryogenic piping. It uses Quest's innovative discrete-spacer technology to control layer spacing/ density and reduce heat leak. The Phase I project successfully designed, built, and tested a wMLI prototype with a measured heat leak 3.6X lower than spiral-wrapped conventional MLI widely used for piping insulation. A wMLI prototype had a heat leak of 7.3 W/m2, or 27 percent of the heat leak of conventional MLI (26.7 W/m2). The Phase II project is further developing wMLI technology with custom, molded polymer spacers and advancing the product toward commercialization via a rigorous testing program, including developing advanced vacuuminsulated pipe for ground support equipment.

  4. Needle free injection technology: A complete insight

    PubMed Central

    Ravi, Ansh Dev; Sadhna, D; Nagpaal, D; Chawla, L

    2015-01-01

    Needle free injection technology (NFIT)is an extremely broad concept which include a wide range of drug delivery systems that drive drugs through the skin using any of the forces as Lorentz, Shock waves, pressure by gas or electrophoresis which propels the drug through the skin, virtually nullifying the use of hypodermic needle. This technology is not only touted to be beneficial for the pharma industry but developing world too find it highly useful in mass immunization programmes, bypassing the chances of needle stick injuries and avoiding other complications including those arising due to multiple use of single needle. The NFIT devices can be classified based on their working, type of load, mechanism of drug delivery and site of delivery. To administer a stable, safe and an effective dose through NFIT, the sterility, shelf life and viscosity of drug are the main components which should be taken care of. Technically superior needle-free injection systems are able to administer highly viscous drug products which cannot be administered by traditional needle and syringe systems, further adding to the usefulness of the technology. NFIT devices can be manufactured in a variety of ways; however the widely employed procedure to manufacture it is by injection molding technique. There are many variants of this technology which are being marketed, such as Bioject® ZetaJetTM, Vitajet 3, Tev-Tropin® and so on. Larger investment has been made in developing this technology with several devices already being available in the market post FDA clearance and a great market worldwide. PMID:26682189

  5. Needle free injection technology: A complete insight.

    PubMed

    Ravi, Ansh Dev; Sadhna, D; Nagpaal, D; Chawla, L

    2015-01-01

    Needle free injection technology (NFIT)is an extremely broad concept which include a wide range of drug delivery systems that drive drugs through the skin using any of the forces as Lorentz, Shock waves, pressure by gas or electrophoresis which propels the drug through the skin, virtually nullifying the use of hypodermic needle. This technology is not only touted to be beneficial for the pharma industry but developing world too find it highly useful in mass immunization programmes, bypassing the chances of needle stick injuries and avoiding other complications including those arising due to multiple use of single needle. The NFIT devices can be classified based on their working, type of load, mechanism of drug delivery and site of delivery. To administer a stable, safe and an effective dose through NFIT, the sterility, shelf life and viscosity of drug are the main components which should be taken care of. Technically superior needle-free injection systems are able to administer highly viscous drug products which cannot be administered by traditional needle and syringe systems, further adding to the usefulness of the technology. NFIT devices can be manufactured in a variety of ways; however the widely employed procedure to manufacture it is by injection molding technique. There are many variants of this technology which are being marketed, such as Bioject(®) ZetaJetTM, Vitajet 3, Tev-Tropin(®) and so on. Larger investment has been made in developing this technology with several devices already being available in the market post FDA clearance and a great market worldwide. PMID:26682189

  6. ["Sham Needle"--Design and Application of A Double-blind Placebo Needle Assembly].

    PubMed

    Yan, Liu; Ma, Li-hong

    2016-02-01

    The blind study design, particularly the double-blind study design is a very important method for diminishing placebo effect and reducing bias in clinical medical trial. Enlightened by Streitberger's and Park's sham needle design, the authors of the present paper introduce a newly designed sham needle device (Yan's sham-needle) for controlled double-blind trials of acupuncture. This sham needle device consists of needle, tube and base. The bottom of the tube is completely sealed and it can never arouse any invasive stimulation on the subject's skin when the sham needle is downward pressed on the body surface. Meanwhile, this sham device is filled with sponge which is able to simulate soft tissues of the acupoint area. By combining words suggestions or hints before trials and the same shape as verum device, this sham-needle device reduces the risk of blind-breaking and makes it possible to conduct controlled double-blind trials. Primary practice showed that this device may provide a new and practical tool for researching the placebo effect of acupuncture therapy. PMID:27141628

  7. Syringe and Needle Size, Syringe Type, Vacuum Generation, and Needle Control in Aspiration Procedures

    SciTech Connect

    Haseler, Luke J.; Sibbitt, Randy R.; Sibbitt, Wilmer L.; Michael, Adrian A.; Gasparovic, Charles M.; Bankhurst, Arthur D.

    2011-06-15

    Purpose: Syringes are used for diagnostic fluid aspiration and fine-needle aspiration biopsy in interventional procedures. We determined the benefits, disadvantages, and patient safety implications of syringe and needle size on vacuum generation, hand force requirements, biopsy/fluid yield, and needle control during aspiration procedures. Materials and Methods: Different sizes (1, 3, 5, 10, and 20 ml) of the conventional syringe and aspirating mechanical safety syringe, the reciprocating procedure device, were studied. Twenty operators performed aspiration procedures with the following outcomes measured: (1) vacuum (torr), (2) time to vacuum (s), (3) hand force to generate vacuum (torr-cm{sup 2}), (4) operator difficulty during aspiration, (5) biopsy yield (mg), and (6) operator control of the needle tip position (mm). Results: Vacuum increased tissue biopsy yield at all needle diameters (P < 0.002). Twenty-milliliter syringes achieved a vacuum of -517 torr but required far more strength to aspirate, and resulted in significant loss of needle control (P < 0.002). The 10-ml syringe generated only 15% less vacuum (-435 torr) than the 20-ml device and required much less hand strength. The mechanical syringe generated identical vacuum at all syringe sizes with less hand force (P < 0.002) and provided significantly enhanced needle control (P < 0.002). Conclusions: To optimize patient safety and control of the needle, and to maximize fluid and tissue yield during aspiration procedures, a two-handed technique and the smallest syringe size adequate for the procedure should be used. If precise needle control or one-handed operation is required, a mechanical safety syringe should be considered.

  8. PET-Based Percutaneous Needle Biopsy.

    PubMed

    El-Haddad, Ghassan

    2016-07-01

    PET can be used to guide percutaneous needle biopsy to the most metabolic lesion, improving diagnostic yield. PET biopsy guidance can be performed using visual or software coregistration, electromagnetic needle tracking, cone-beam computed tomography (CT), and intraprocedural PET/CT guidance. PET/CT-guided biopsies allow the sampling of lesions that may not be clearly visible on anatomic imaging, or of lesions that are morphologically normal. PET can identify suspicious locations within complex tumors that are most likely to contain important diagnostic and prognostic information. PMID:27321036

  9. Transbronchial needle aspiration. An underused diagnostic technique.

    PubMed

    Dasgupta, A; Mehta, A C

    1999-03-01

    Despite its proven usefulness, TBNA is not widely used. An American College of Chest Physicians (ACCP) survey showed that only 11.8% of pulmonologists use TBNA. Most pulmonologists in the 1980s were not formally trained in TBNA. This lack of training has unfortunately translated to minimal emphasis on TBNA in current training programs in a large number of institutions. Technical problems with the procedure (faulty site selection, incomplete needle penetration, catheter kinking that prevents adequate suction, etc.), the confusing array of needles, low diagnostic yields, unproven concerns regarding the safety of the procedure, inadequate cytopathology support, and bronchoscopic damage have all perpetuated the image of limited usefulness for this procedure. Limitations to the practice of TBNA are: Lack of training during fellowship Technical inadequacies Lack of cytopathologists trained in TBNA interpretation Fear of bronchoscope damage Safety issues Failure to reproduce published successes Reservations regarding usefulness of TBNA results Hands-on experience with TBNA, developing familiarity and expertise with only a few needles, and paying careful attention to anatomy, procedure techniques, and specimen acquisition may all help to increase yield. The following lists how better results can be obtained with TBNA: Preprocedure Review TBNA instruction tapes Attend hands-on courses Practice with lung models Review patient's CAT scans Familiarize with one-two cytology and histology needle Obtain a trained assistant Procedural Identify target site Needle to airway angle at least greater than 45 degrees Insert entire length of the needle Use scope channel to support the catheter Release suction before withdrawing needle (for staging) Specimen acquisition Avoid delay in preparing slides Adequate sampling (at least two) Use smear method for cytology specimen Analyze all samples flush solutions cell block Postprocedure Find an experienced cytopathologist Review your procedure

  10. 21 CFR 890.1385 - Diagnostic electromyograph needle electrode.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... needle electrode is a monopolar or bipolar needle intended to be inserted into muscle or nerve tissue to... electromyography (recording the intrinsic electrical properties of skeletal muscle). (b) Classification. Class...

  11. 21 CFR 890.1385 - Diagnostic electromyograph needle electrode.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... needle electrode is a monopolar or bipolar needle intended to be inserted into muscle or nerve tissue to... electromyography (recording the intrinsic electrical properties of skeletal muscle). (b) Classification. Class...

  12. 21 CFR 890.1385 - Diagnostic electromyograph needle electrode.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... needle electrode is a monopolar or bipolar needle intended to be inserted into muscle or nerve tissue to... electromyography (recording the intrinsic electrical properties of skeletal muscle). (b) Classification. Class...

  13. 21 CFR 890.1385 - Diagnostic electromyograph needle electrode.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... needle electrode is a monopolar or bipolar needle intended to be inserted into muscle or nerve tissue to... electromyography (recording the intrinsic electrical properties of skeletal muscle). (b) Classification. Class...

  14. 21 CFR 890.1385 - Diagnostic electromyograph needle electrode.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... needle electrode is a monopolar or bipolar needle intended to be inserted into muscle or nerve tissue to... electromyography (recording the intrinsic electrical properties of skeletal muscle). (b) Classification. Class...

  15. 41. VALVEHOUSE FOR NEEDLE VALVE OUTLET WORKS ON GALLERY 2, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    41. VALVEHOUSE FOR NEEDLE VALVE OUTLET WORKS ON GALLERY 2, SHOWING NEEDLE VALVE CONTROL PEDESTALS (MANUFACTURED BY AMERICAN LOCOMOTIVE COMPANY) IN LEFT FOREGROUND AND RIGHT BACKGROUND. VIEW TO NORTHEAST. - Owyhee Dam, Across Owyhee River, Nyssa, Malheur County, OR

  16. Acoustic Radiation Force Impulse (ARFI) Imaging-Based Needle Visualization

    PubMed Central

    Rotemberg, Veronica; Palmeri, Mark; Rosenzweig, Stephen; Grant, Stuart; Macleod, David; Nightingale, Kathryn

    2011-01-01

    Ultrasound-guided needle placement is widely used in the clinical setting, particularly for central venous catheter placement, tissue biopsy and regional anesthesia. Difficulties with ultrasound guidance in these areas often result from steep needle insertion angles and spatial offsets between the imaging plane and the needle. Acoustic Radiation Force Impulse (ARFI) imaging leads to improved needle visualization because it uses a standard diagnostic scanner to perform radiation force based elasticity imaging, creating a displacement map that displays tissue stiffness variations. The needle visualization in ARFI images is independent of needle-insertion angle and also extends needle visibility out of plane. Although ARFI images portray needles well, they often do not contain the usual B-mode landmarks. Therefore, a three-step segmentation algorithm has been developed to identify a needle in an ARFI image and overlay the needle prediction on a coregistered B-mode image. The steps are: (1) contrast enhancement by median filtration and Laplacian operator filtration, (2) noise suppression through displacement estimate correlation coefficient thresholding and (3) smoothing by removal of outliers and best-fit line prediction. The algorithm was applied to data sets from horizontal 18, 21 and 25 gauge needles between 0–4 mm offset in elevation from the transducer imaging plane and to 18G needles on the transducer axis (in plane) between 10° and 35° from the horizontal. Needle tips were visualized within 2 mm of their actual position for both horizontal needle orientations up to 1.5 mm off set in elevation from the transducer imaging plane and on-axis angled needles between 10°–35° above the horizontal orientation. We conclude that segmented ARFI images overlaid on matched B-mode images hold promise for improved needle visibility in many clinical applications. PMID:21608445

  17. Treatment of in-transit melanoma with intralesional bacillus Calmette-Guérin (BCG) and topical imiquimod 5% cream: a report of 3 cases.

    PubMed

    Kibbi, Nour; Ariyan, Stephan; Faries, Mark; Choi, Jennifer N

    2015-01-01

    Local therapy for in-transit melanoma (ITM) is a treatment alternative for patients who are not good candidates for systemic therapy, regional therapy, or surgical management. In this case report, we describe 3 patients with ITM who were treated with intralesional Bacillus Calmette-Guérin (ILBCG) and/or topical imiquimod. Treatment course was dictated by the clinical response. Patient 1's response to ILBCG monotherapy was not sufficient to cause disease regression; however, transition to topical imiquimod therapy resulted in complete and sustained response. Although patient 2 responded to ILBCG and imiquimod, she developed a hypersensitivity reaction to ILBCG; when topical imiquimod was continued as monotherapy, her clinical response was complete. Patient 3 responded completely to ILBCG monotherapy in injected lesions, but expired shortly thereafter from unrelated disease. Reports like this one are needed to define the success measures of local therapy in the treatment of ITM. PMID:26448581

  18. Treatment of In-Transit Melanoma With Intralesional Bacillus Calmette-Guérin (BCG) and Topical Imiquimod 5% Cream: A Report of 3 Cases

    PubMed Central

    Kibbi, Nour; Ariyan, Stephan; Faries, Mark

    2015-01-01

    Local therapy for in-transit melanoma (ITM) is a treatment alternative for patients who are not good candidates for systemic therapy, regional therapy, or surgical management. In this case report, we describe 3 patients with ITM who were treated with intralesional Bacillus Calmette-Guérin (ILBCG) and/or topical imiquimod. Treatment course was dictated by the clinical response. Patient 1’s response to ILBCG monotherapy was not sufficient to cause disease regression; however, transition to topical imiquimod therapy resulted in complete and sustained response. Although patient 2 responded to ILBCG and imiquimod, she developed a hypersensitivity reaction to ILBCG; when topical imiquimod was continued as monotherapy, her clinical response was complete. Patient 3 responded completely to ILBCG monotherapy in injected lesions, but expired shortly thereafter from unrelated disease. Reports like this one are needed to define the success measures of local therapy in the treatment of ITM. PMID:26448581

  19. Thermal insulated glazing unit

    DOEpatents

    Selkowitz, Stephen E.; Arasteh, Dariush K.; Hartmann, John L.

    1991-01-01

    An improved insulated glazing unit is provided which can attain about R5 to about R10 thermal performance at the center of the glass while having dimensions about the same as those of a conventional double glazed insulated glazing unit. An outer glazing and inner glazing are sealed to a spacer to form a gas impermeable space. One or more rigid, non-structural glazings are attached to the inside of the spacer to divide the space between the inner and outer glazings to provide insulating gaps between glazings of from about 0.20 inches to about 0.40 inches. One or more glazing surfaces facing each thermal gap are coated with a low emissivity coating. Finally, the thermal gaps are filled with a low conductance gas such as krypton gas.

  20. Thermal insulated glazing unit

    DOEpatents

    Selkowitz, S.E.; Arasteh, D.K.; Hartmann, J.L.

    1988-04-05

    An improved insulated glazing unit is provided which can attain about R5 to about R10 thermal performance at the center of the glass while having dimensions about the same as those of a conventional double glazed insulated glazing unit. An outer glazing and inner glazing are sealed to a spacer to form a gas impermeable space. One or more rigid, non-structural glazings are attached to the inside of the spacer to divide the space between the inner and outer glazings to provide insulating gaps between glazings of from about 0.20 inches to about 0.40 inches. One or more glazing surfaces facing each thermal gap are coated with a low emissivity coating. Finally, the thermal gaps are filled with a low conductance gas such as krypton gas. 2 figs.

  1. Insulation bonding test system

    NASA Technical Reports Server (NTRS)

    Beggs, J. M.; Johnston, G. D.; Coleman, A. D.; Portwood, J. N.; Saunders, J. M.; Redmon, J. W.; Porter, A. C. (Inventor)

    1984-01-01

    A method and a system for testing the bonding of foam insulation attached to metal is described. The system involves the use of an impacter which has a calibrated load cell mounted on a plunger and a hammer head mounted on the end of the plunger. When the impacter strikes the insulation at a point to be tested, the load cell measures the force of the impact and the precise time interval during which the hammer head is in contact with the insulation. This information is transmitted as an electrical signal to a load cell amplifier where the signal is conditioned and then transmitted to a fast Fourier transform (FFT) analyzer. The FFT analyzer produces energy spectral density curves which are displayed on a video screen. The termination frequency of the energy spectral density curve may be compared with a predetermined empirical scale to determine whether a igh quality bond, good bond, or debond is present at the point of impact.

  2. Reusable Surface Insulation

    NASA Technical Reports Server (NTRS)

    1997-01-01

    Advanced Flexible Reusable Surface Insulation, developed by Ames Research Center, protects the Space Shuttle from the searing heat that engulfs it on reentry into the Earth's atmosphere. Initially integrated into the Space Shuttle by Rockwell International, production was transferred to Hi-Temp Insulation Inc. in 1974. Over the years, Hi-Temp has created many new technologies to meet the requirements of the Space Shuttle program. This expertise is also used commercially, including insulation blankets to cover aircrafts parts, fire barrier material to protect aircraft engine cowlings and aircraft rescue fire fighter suits. A Fire Protection Division has also been established, offering the first suit designed exclusively by and for aircraft rescue fire fighters. Hi-Temp is a supplier to the Los Angeles City Fire Department as well as other major U.S. civil and military fire departments.

  3. ASRM Case Insulation development

    NASA Astrophysics Data System (ADS)

    Tam, W. F. S.; Bell, M.

    1993-06-01

    The ASRM Case Insulation Program used design of experiments to develop a high performance case insulation. The program traded-off more than thirty properties in areas of ablation performance, material properties, processibility, bonding/aging. Kevlar pulp was found to be the most significant factor. The low-molecular weight ethylene propylene diene monomer, EPDM was the second most significant factor. The curative was the third most significant factor. The tackifier was the fourth most significant factor. The stripwinding process for applying the insulation onto the case inner surfaces was also studied. The parameters selected for experiment were extruder speed, upper roller temperature and extruder nozzle temperature. The extrudability results showed that non-Kevlar filled formulations displayed optimum edges but poor thickness continuity. High Kevlar filled formulations displayed optimum thickness continuity but poor strip edge ratings.

  4. ASRM Case Insulation development

    NASA Technical Reports Server (NTRS)

    Tam, W. F. S.; Bell, M.

    1993-01-01

    The ASRM Case Insulation Program used design of experiments to develop a high performance case insulation. The program traded-off more than thirty properties in areas of ablation performance, material properties, processibility, bonding/aging. Kevlar pulp was found to be the most significant factor. The low-molecular weight ethylene propylene diene monomer, EPDM was the second most significant factor. The curative was the third most significant factor. The tackifier was the fourth most significant factor. The stripwinding process for applying the insulation onto the case inner surfaces was also studied. The parameters selected for experiment were extruder speed, upper roller temperature and extruder nozzle temperature. The extrudability results showed that non-Kevlar filled formulations displayed optimum edges but poor thickness continuity. High Kevlar filled formulations displayed optimum thickness continuity but poor strip edge ratings.

  5. Thin needle aspiration biopsy of endocrine organs.

    PubMed

    Koss, L G

    1979-01-01

    The purpose of this paper is to summarize the advantages and disadvantages of the fine needle aspiration technique in reference to the endocrine organs. The principles of technique and interpretation are presented. The application of aspiration biopsies to the breast, the prostate, the pancreas and the thyroid are briefly discussed. PMID:485094

  6. Genetics Home Reference: Melnick-Needles syndrome

    MedlinePlus

    ... or buccal smear. Am J Med Genet. 2002 Mar 1;108(2):120-7. Citation on PubMed OMIM: ... 2003 Apr;33(4):487-91. Epub 2003 Mar 3. Citation on ... syndrome types 1 and 2, frontometaphyseal dysplasia and Melnick-Needles syndrome. ...

  7. A Modification to Maxwell's Needle Apparatus

    ERIC Educational Resources Information Center

    Soorya, Tribhuvan N.

    2015-01-01

    Maxwell's needle apparatus is used to determine the shear modulus (?) of the material of a wire of uniform cylindrical cross section. Conventionally, a single observation is taken for each observable, and the value of ? is calculated in a single shot. A modification to the above apparatus is made by varying one of the observables, namely the mass…

  8. The Single Needle Lockstitch Machine. Module 1.

    ERIC Educational Resources Information Center

    South Carolina State Dept. of Education, Columbia. Office of Vocational Education.

    This module on parts of the machine, one in a series on the single needle lockstitch sewing machine for student self-study, contains eight sections. Each section contains the following parts: an introduction, directions, an objective, learning activities, student information, student self-check, check-out activities, and an instructor's final…

  9. Particulate contamination of sterile syringes and needles.

    PubMed

    Taylor, S A

    1982-08-01

    Commercially available sterile needles and syringes have been examined for particulate contamination using the Hiac light blockage technique. The number of particles delivered was small compared with the total number permitted for large volume parenterals. Where syringes are used in particle counting techniques, the contribution of particles should be taken into account. PMID:6126558

  10. Three-Dimensional Sonography With Needle Tracking

    PubMed Central

    Shen, Feimo; Shinohara, Katsuto; Kumar, Dinesh; Khemka, Animesh; Simoneau, Anne R.; Werahera, Priya N.; Li, Lu; Guo, Yujun; Narayanan, Ramkrishnan; Wei, Liyang; Al Barqawi; Crawford, E. David; Davatzikos, Christos; Suri, Jasjit S.

    2012-01-01

    Objective Image-guided prostate biopsy has become routine in medical diagnosis. Although it improves biopsy outcome, it mostly operates in 2 dimensions, therefore lacking presentation of information in the complete 3-dimensional (3D) space. Because prostatic carcinomas are nonuniformly distributed within the prostate gland, it is crucial to accurately guide the needles toward clinically important locations within the 3D volume for both diagnosis and treatment. Methods We reviewed the uses of 3D image-guided needle procedures in prostate cancer diagnosis and cancer therapy as well as their advantages, work flow, and future directions. Results Guided procedures for the prostate rely on accurate 3D target identification and needle navigation. This 3D approach has potential for better disease diagnosis and therapy. Additionally, when fusing together different imaging modalities and cancer probability maps obtained from a population of interest, physicians can potentially place biopsy needles and other interventional devices more accurately and efficiently by better targeting regions that are likely to host cancerous tissue. Conclusions With the information from anatomic, metabolic, functional, biochemical, and biomechanical statuses of different regions of the entire gland, prostate cancers will be better diagnosed and treated with improved work flow. PMID:18499849

  11. Modeling and control of needles with torsional friction.

    PubMed

    Reed, Kyle B; Okamura, Allison M; Cowan, Noah J

    2009-12-01

    A flexible needle can be accurately steered by robotically controlling the bevel tip orientation as the needle is inserted into tissue. Friction between the long, flexible needle shaft and the tissue can cause a significant discrepancy between the orientation of the needle tip and the orientation of the base where the needle angle is controlled. Our experiments show that several common phantom tissues used in needle steering experiments impart substantial friction forces to the needle shaft, resulting in a lag of more than 45 ( degrees ) for a 10 cm insertion depth in some phantoms; clinical studies report torques large enough to cause similar errors during needle insertions. Such angle discrepancies will result in poor performance or failure of path planners and image-guided controllers, since the needles used in percutaneous procedures are too small for state-of-the-art imaging to accurately measure the tip angle. To compensate for the angle discrepancy, we develop an estimator using a mechanics-based model of the rotational dynamics of a needle being inserted into tissue. Compared to controllers that assume a rigid needle in a frictionless environment, our estimator-based controller improves the tip angle convergence time by nearly 50% and reduces the path deviation of the needle by 70%. PMID:19695979

  12. Hollow needle used to cut metal honeycomb structures

    NASA Technical Reports Server (NTRS)

    Gregg, E. A.

    1966-01-01

    Hollow needle tool cuts metal honeycomb structures without damaging adjacent material. The hollow needle combines an electrostatic discharge and a stream of oxygen at a common point to effect rapid, accurate metal cutting. The tool design can be varied to use the hollow needle principle for cutting a variety of shapes.

  13. 21 CFR 884.6100 - Assisted reproduction needles.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Assisted reproduction needles. 884.6100 Section... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Assisted Reproduction Devices § 884.6100 Assisted reproduction needles. (a) Identification. Assisted reproduction needles are devices used in...

  14. 21 CFR 884.6100 - Assisted reproduction needles.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Assisted reproduction needles. 884.6100 Section... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Assisted Reproduction Devices § 884.6100 Assisted reproduction needles. (a) Identification. Assisted reproduction needles are devices used in...

  15. 21 CFR 884.6100 - Assisted reproduction needles.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Assisted reproduction needles. 884.6100 Section... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Assisted Reproduction Devices § 884.6100 Assisted reproduction needles. (a) Identification. Assisted reproduction needles are devices used in...

  16. 21 CFR 884.6100 - Assisted reproduction needles.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Assisted reproduction needles. 884.6100 Section... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Assisted Reproduction Devices § 884.6100 Assisted reproduction needles. (a) Identification. Assisted reproduction needles are devices used in...

  17. 21 CFR 884.6100 - Assisted reproduction needles.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Assisted reproduction needles. 884.6100 Section... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Assisted Reproduction Devices § 884.6100 Assisted reproduction needles. (a) Identification. Assisted reproduction needles are devices used in...

  18. 21 CFR 872.4730 - Dental injecting needle.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Dental injecting needle. 872.4730 Section 872.4730...) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4730 Dental injecting needle. (a) Identification. A dental injecting needle is a slender, hollow metal device with a sharp point intended to be attached to...

  19. 21 CFR 872.4730 - Dental injecting needle.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental injecting needle. 872.4730 Section 872.4730...) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4730 Dental injecting needle. (a) Identification. A dental injecting needle is a slender, hollow metal device with a sharp point intended to be attached to...

  20. 21 CFR 872.4730 - Dental injecting needle.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Dental injecting needle. 872.4730 Section 872.4730...) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4730 Dental injecting needle. (a) Identification. A dental injecting needle is a slender, hollow metal device with a sharp point intended to be attached to...

  1. 21 CFR 872.4730 - Dental injecting needle.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Dental injecting needle. 872.4730 Section 872.4730...) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4730 Dental injecting needle. (a) Identification. A dental injecting needle is a slender, hollow metal device with a sharp point intended to be attached to...

  2. 21 CFR 872.4730 - Dental injecting needle.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Dental injecting needle. 872.4730 Section 872.4730...) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4730 Dental injecting needle. (a) Identification. A dental injecting needle is a slender, hollow metal device with a sharp point intended to be attached to...

  3. 21 CFR 868.5150 - Anesthesia conduction needle.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Anesthesia conduction needle. 868.5150 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5150 Anesthesia conduction needle. (a) Identification. An anesthesia conduction needle is a device used to inject local anesthetics into a patient...

  4. 21 CFR 868.5150 - Anesthesia conduction needle.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Anesthesia conduction needle. 868.5150 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5150 Anesthesia conduction needle. (a) Identification. An anesthesia conduction needle is a device used to inject local anesthetics into a patient...

  5. 21 CFR 868.5150 - Anesthesia conduction needle.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Anesthesia conduction needle. 868.5150 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5150 Anesthesia conduction needle. (a) Identification. An anesthesia conduction needle is a device used to inject local anesthetics into a patient...

  6. 21 CFR 868.5150 - Anesthesia conduction needle.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Anesthesia conduction needle. 868.5150 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5150 Anesthesia conduction needle. (a) Identification. An anesthesia conduction needle is a device used to inject local anesthetics into a patient...

  7. 21 CFR 868.5150 - Anesthesia conduction needle.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Anesthesia conduction needle. 868.5150 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5150 Anesthesia conduction needle. (a) Identification. An anesthesia conduction needle is a device used to inject local anesthetics into a patient...

  8. The Double-Needle Felling Machine. Module 17.

    ERIC Educational Resources Information Center

    South Carolina State Dept. of Education, Columbia. Office of Vocational Education.

    This module on the double-needle felling machine, one in a series dealing with industrial sewing machines, their attachments, and operation, covers two topics: performing special operations on the double-needle felling machine (straight seams) and performing special operations on the double-needle felling machine (curved flat-felled seams). For…

  9. Modeling and Control of Needles with Torsional Friction

    PubMed Central

    Reed, Kyle B.; Okamura, Allison M.; Cowan, Noah J.

    2010-01-01

    A flexible needle can be accurately steered by robotically controlling the bevel tip orientation as the needle is inserted into tissue. Friction between the long, flexible needle shaft and the tissue can cause a significant discrepancy between the orientation of the needle tip and the orientation of the base where the needle angle is controlled. Our experiments show that several common phantom tissues used in needle steering experiments impart substantial friction forces to the needle shaft, resulting in a lag of over 45° for a 10 cm insertion depth in some phantoms; clinical studies report torques large enough to cause similar errors during needle insertions. Such angle discrepancies will result in poor performance or failure of path planners and image-guided controllers, since the needles used in percutaneous procedures are too small for state-of-the-art imaging to accurately measure the tip angle. To compensate for the angle discrepancy, we develop an estimator using a mechanics-based model of the rotational dynamics of a needle being inserted into tissue. Compared to controllers that assume a rigid needle in a frictionless environment, our estimator-based controller improves the tip angle convergence time by nearly 50% and reduces the path deviation of the needle by 70%. PMID:19695979

  10. Single-Camera Closed-Form Real-Time Needle Tracking for Ultrasound-Guided Needle Insertion.

    PubMed

    Najafi, Mohammad; Abolmaesumi, Purang; Rohling, Robert

    2015-10-01

    Many common needle intervention procedures are performed with ultrasound guidance because it is a flexible, cost-effective and widely available intra-operative imaging modality. In a needle insertion procedure with ultrasound guidance, real-time calculation and visualization of the needle trajectory can help to guide the choice of puncture site and needle angle to reach the target depicted in the ultrasound image. We found that it is feasible to calculate the needle trajectory with a single camera mounted directly on the ultrasound transducer by using the needle markings. Higher accuracy is achieved compared with other similar transducer-mounted needle trackers. We used an inexpensive, real-time and easy-to-use tracking method based on an automatic feature extraction algorithm and a closed-form method for pose estimation of the needle. The overall accuracy was 0.94 ± 0.46 mm. PMID:26215491

  11. Transparent evacuated insulation

    SciTech Connect

    Collins, R.E.; Fischer-Cripps, A.C.; Tang, J.Z. )

    1992-11-01

    Transparent evacuated insulation utilizes the same operating principles as the Dewar flask - gas conduction and convection are essentially eliminated by the evacuated space, and radiative heat transport is small because of internal low emittance coatings. These insulating structures consist of two flat sheets of glass with a hermetic edge seal. An array of support pillars is necessary to maintain the separation of the glass sheets under the influence of atmospheric pressure. The extensive literature on transparent evacuated insulation is reviewed. The design of these devices involves trade-offs between the heat flow through the pillars, and the mechanical stresses. A design methodology for determining the dimensions of the pillar array is developed. An analytic method is described for calculating the stresses and bending produced by a temperature difference across the structure. The results are in reasonable agreement with experimental measurements. The stresses within the structure are shown to be less than conventionally accepted levels over a wider range of operating conditions. Many samples of transparent evacuated insulation have been built and tested in which the heat transport through the evacuated space is due entirely to radiation, to the limit of resolution of the measuring device (0.2 W m{sup {minus}2}K{sup {minus}1}). No increase in heat transport has been observed over a period of 18 months. Much higher accuracy measurements have commenced. It appears likely that transparent evacuated insulation will achieve mid-plane insulating values of 0.6 W m{sup {minus}2}K{sup {minus}1}, and possibly somewhat lower.

  12. Transplantation of Mesenchymal Stem Cells for Acute Spinal Cord Injury in Rats: Comparative Study between Intralesional Injection and Scaffold Based Transplantation.

    PubMed

    Kim, Yoon Chung; Kim, Young Hoon; Kim, Jang Woon; Ha, Kee Yong

    2016-09-01

    Experimental stem cell therapy for spinal cord injury (SCI) has been extensively investigated. The selection of effective cell transplantation route is also an important issue. Although various types of scaffold have been widely tried as a carrier of stem cells to the injured spinal cord, there was little comparative study to investigate the efficacy of transplantation comparing with conventional transplantation route. A total of 48 Sprague-Dawley rats were subjected to standardized SCI, followed by transplantation of allogeneic mesenchymal stem cells (MSCs), either via intralesional injection (IL group), or via the poly (lactic-co-glycolic acid) (PLGA) scaffold (IP group) or chitosan scaffold (IC group). Engraftment and differentiation of the transplanted cells, expression of neurotrophic factors in the injured spinal cord, and functional recovery were compared with those of the control group. The mean numbers of engrafted MSCs in the IL, IP, and IC groups were 20.6 ± 0.7, 25.6 ± 1.7 and 26.7 ± 1.8 cells/high power filed (HPF), respectively. Results showed higher success rate of MSCs engraftment in the scaffold groups compared to the IL group. Expression of neuroprotective growth factors in the SCI lesions showed no significant differences between the IL, IP, and IC groups. The mean Basso, Beattie and Bresnahan locomotor scales at 6 weeks post-transplantation in the IL, IP, IC, and control groups were 7.9 ± 1.1, 7.9 ± 2.1, 8.7 ± 2.1, and 2.9 ± 1.0, respectively. The functional improvement was most excellent in the IC group. The scaffold based MSC transplantation for acute SCI presented the better cell engraftment and neuroprotective effect compared to the intralesional injection transplantation. PMID:27510379

  13. Measuring Building Insulation

    NASA Astrophysics Data System (ADS)

    Parks, Beth

    2013-03-01

    Currently, the only way for homeowners to learn about the effectiveness of their home insulation is to hire an energy auditor. This difficulty deters homeowners from taking action to improve energy efficiency. In principle, measuring the temperature difference between a wall surface and the interior of a home is sufficient to determine the wall insulation, but in practice, temperature cycles from the heating system make a single measurement unreliable. I will describe a simple and inexpensive thermocouple-based device to measure this temperature difference and report results obtained by monitoring this temperature difference over multiple heating cycles in a range of buildings. Patent application 12/555371

  14. Thermal insulating material

    SciTech Connect

    Billings, P.J.

    1981-12-08

    A thermal insulating material which includes silicone coated perlite providing thermal insulation, powdered perlite to fill in the gaps between the silicone coated perlite particle, and a specially formulated binder for the perlite is disclosed. The binder has a powder portion comprising a mixture of gypsum and cement for strength and a liquid portion comprising polyvinyl acetate, a colloid and water. After these materials are mixed in proper proportions, water is added to provide the fluidity necessary for application, such as by spraying or molding into prefabricated panels.

  15. Topological Mott Insulators

    SciTech Connect

    Raghu, S.

    2010-03-02

    We consider extended Hubbard models with repulsive interactions on a honeycomb lattice, and the transitions from the semimetal to Mott insulating phases at half-filling. Because of the frustrated nature of the second-neighbor interactions, topological Mott phases displaying the quantum Hall and the quantum spin Hall effects are found for spinless and spin fermion models, respectively. The mean-field phase diagram is presented and the fluctuations are treated within the random phase approximation. Renormalization group analysis shows that these states can be favored over the topologically trivial Mott insulating states.

  16. Acupuncture sensation during ultrasound guided acupuncture needling

    PubMed Central

    Park, Jongbae J.; Akazawa, Margeaux; Ahn, Jaeki; Beckman-Harned, Selena; Lin, Feng-Chang; Lee, Kwangjae; Fine, Jason; Davis, Robert T; Langevin, Helene

    2014-01-01

    Background Although acupuncture sensation (also known as de qi) is a cornerstone of traditional acupuncture therapy, most research has accepted the traditional method of defining acupuncture sensation only through subjective patient reports rather than on any quantifiable physiological basis. Purpose To preliminarily investigate the frequency of key sensations experienced while needling to specific, quantifiable tissue levels (TLs) guided by ultrasound (US) imaging. Methods Five participants received needling at two acupuncture points and two control points at four TLs. US scans were used to determine when each TL was reached. Each volunteer completed 32 sets of modified Southampton Needle Sensation Questionnaires. Part one of the study tested sensations experienced at each TL and part two compared the effect of oscillation alone versus oscillation + rotation. Results In all volunteers, the frequency of pricking, sharp sensations was significantly greater in shallower TLs than deeper (p=0.007); the frequency of sensations described as deep, dull and heavy, as spreading, and as electric shocks was significantly greater in deeper TLs than shallower (p=0.002). Sensations experienced did not significantly differ between real and control points within each of three TLs (p>0.05) except TL 4 (p=0.006). The introduction of needle rotation significantly increased deep, dull, heavy sensations, but not pricking and sharp sensations; within each level, the spectrum of sensation experienced during both oscillation + rotation and oscillation alone did not significantly differ between acupuncture and control points. Conclusion The preliminary study indicates a strong connection between acupuncture sensation and both tissue depth and needle rotation. Furthermore, the new methodology has been proven feasible. A further study with an objective measurement is warranted. PMID:21642648

  17. Macroscopic and microscopic observations of needle insertion into gels.

    PubMed

    van Veen, Youri R J; Jahya, Alex; Misra, Sarthak

    2012-06-01

    Needle insertion into soft tissue is one of the most common medical interventions. This study provides macroscopic and microscopic observations of needle-gel interactions. A gelatin mixture is used as a soft-tissue simulant. For the macroscopic studies, system parameters, such as insertion velocity, needle diameter, gel elasticity, needle tip shape (including bevel angle) and insertion motion profile, are varied, while the maximum insertion force and maximum needle deflection are recorded. The needle tip and gel interactions are observed using confocal microscopic images. Observations indicate that increasing the insertion velocity and needle diameter results in larger insertion forces and smaller needle deflections. Varying the needle bevel angle from 8 degrees to 82 degrees results in the insertion force increasing monotonically, while the needle deflection does not. These variations are due to the coupling between gel rupture and tip compression interactions, which are observed during microscopic studies. Increasing the gel elasticity results in larger insertion forces and needle deflections. Varying the tip shapes demonstrates that bevel-tipped needles produce the largest deflection, but insertion force does not vary among the tested tip shapes. Insertion with different motion profiles are performed. Results show that adding I Hz rotational motion during linear insertion decreases the needle deflection. Increasing the rotational motion from I Hz to 5 Hz decreases the insertion force, while the needle deflection remains the same. A high-velocity (250 mm/s and 300 mm/s) tapping during insertion yields no significant decrease in needle deflection and a slight increase in insertion force. PMID:22783760

  18. Foam Insulation for Cryogenic Flowlines

    NASA Technical Reports Server (NTRS)

    Sonju, T. R.; Carbone, R. L.; Oves, R. E.

    1985-01-01

    Welded stainless-steel vacuum jackets on cryogenic ducts replaced by plastic foam-insulation jackets that weigh 12 percent less. Foam insulation has 85 percent of insulating ability of stainless-steel jacketing enclosing vacuum of 10 microns of mercury. Foam insulation easier to install than vacuum jacket. Moreover, foam less sensitive to damage and requires minimal maintenance. Resists vibration and expected to have service life of at least 10 years.

  19. Self-Healing Wire Insulation

    NASA Technical Reports Server (NTRS)

    Parrish, Clyde F. (Inventor)

    2012-01-01

    A self-healing system for an insulation material initiates a self-repair process by rupturing a plurality of microcapsules disposed on the insulation material. When the plurality of microcapsules are ruptured, reactants within the plurality of microcapsules react to form a replacement polymer in a break of the insulation material. This self-healing system has the ability to repair multiple breaks in a length of insulation material without exhausting the repair properties of the material.

  20. Dual mode fuel injector with one piece needle valve member

    DOEpatents

    Lawrence, Keith E.; Hinrichsen, Michael H.; Buckman, Colby

    2005-01-18

    A fuel injector includes a homogenous charge nozzle outlet set and a conventional nozzle outlet set controlled respectively by inner and outer needle value members. The homogenous charged nozzle outlet set is defined by an outer needle value member that is moveably positioned in an injector body, which defines the conventional nozzle outlet set. The inner needle valve member is positioned in the outer needle valve member. The outer needle valve member is a piece component that includes at least one external guide surface, an external value surface and an internal valve seat.

  1. Kinematics Analysis of an Aided Robot for Needle Insertion

    NASA Astrophysics Data System (ADS)

    Li, Qiang; Gao, Dedong; Wang, Shan; Bai, Huiquan; Zheng, Haojun

    The kinematic relationship between the needle base and the robot's joints is analyzed. The analysis process is based on the aided needle-insertion robot built by our group. The thinking of needle-inserting procedure is confirming the needle base's posture before the needle inserted into tissue. The method of Denavit-Hartenberg (D-H) parameters is used to establish a link robot body-frames with the structural characteristics of the robot. After analysing kinematics, the kinematics equation is presented. The kinematics inverse solutions are obtained with the analytical method and geometry analysis method.

  2. Insulated ECG electrodes

    NASA Technical Reports Server (NTRS)

    Portnoy, W. M.; David, R. M.

    1973-01-01

    Insulated, capacitively coupled electrode does not require electrolyte paste for attachment. Other features of electrode include wide range of nontoxic material that may be employed for dielectric because of sputtering technique used. Also, electrode size is reduced because there is no need for external compensating networks with FET operational amplifier.

  3. Improved insulation material

    NASA Technical Reports Server (NTRS)

    1976-01-01

    Multilayer material consisting of embossed, silver-coated Mylar, nylon net, and silk net is useful for thermal-protection systems and cryogenic containers. Embossing serves two purposes: helps separate radiation barriers and controls radiant energy diffusion. Insulation requires no maintenance after installation.

  4. The Polar Insulation Investigation

    ERIC Educational Resources Information Center

    Urban-Rich, Juanita

    2006-01-01

    In this article, the author developed an activity called "The Polar Insulation Investigation." This activity builds on students' natural interest in "things polar" and introduces them to animal adaptations in a unique way. The aim of the exploration is to determine the role of animal coverings (e.g., blubber, fur, and feathers) and to see which is…

  5. Preassembly Of Insulating Tiles

    NASA Technical Reports Server (NTRS)

    Izu, Y. D.; Yoshioka, E. N.; Rosario, T.

    1988-01-01

    Concept for preassembling high-temperature insulating tiles speeds and simplifies installation and repair and reduces damage from handling. Preassembly concept facilitates placement of tiles on gently contoured surfaces as well as on flat ones. Tiles bonded to nylon mesh with room-temperature-vulcanizing silicon rubber. Spacing between tiles is 0.03 in. Applications include boilers, kilns, and furnaces.

  6. Lightweight Electrical Insulation

    NASA Technical Reports Server (NTRS)

    Schroeder, J. E.

    1985-01-01

    Hollow plastic spheres expanded and fused together. Hollow, gasfilled plastic spheres piled in mold. Heating in vacuum softens and expands spheres, forcing them together into nearly regular hexagonal close packing. Foam used as lightweight, electrically insulating material in place of solid ceramic, glass, or polymer. Padding to protect against mechanical shocks another application for such dense, regular foam.

  7. THERMAL INSULATION SYSTEMS

    NASA Technical Reports Server (NTRS)

    Augustynowicz, Stanislaw D. (Inventor); Fesmire, James E. (Inventor)

    2005-01-01

    Thermal insulation systems and with methods of their production. The thermal insulation systems incorporate at least one reflection layer and at least one spacer layer in an alternating pattern. Each spacer layer includes a fill layer and a carrier layer. The fill layer may be separate from the carrier layer, or it may be a part of the carrier layer, i.e., mechanically injected into the carrier layer or chemically formed in the carrier layer. Fill layers contain a powder having a high surface area and low bulk density. Movement of powder within a fill layer is restricted by electrostatic effects with the reflection layer combined with the presence of a carrier layer, or by containing the powder in the carrier layer. The powder in the spacer layer may be compressed from its bulk density. The thermal insulation systems may further contain an outer casing. Thermal insulation systems may further include strips and seams to form a matrix of sections. Such sections serve to limit loss of powder from a fill layer to a single section and reduce heat losses along the reflection layer.

  8. Erosion of polyurethane insulation.

    NASA Technical Reports Server (NTRS)

    Kraus, S.

    1973-01-01

    Detailed description of the test program in which erosion of the spray foam insulation used in the S-II stage of the Saturn-V Apollo launch vehicle was investigated. The behavior of the spray foam was investigated at the elevated temperature and static pressure appropriate to the S-II stage environment, but in the absence of the aerodynamic shear stress.

  9. Alaska Pipeline Insulation

    NASA Technical Reports Server (NTRS)

    1979-01-01

    Crude oil moving through the 800-mile Trans-Alaska Pipeline must be kept at a relatively high temperature, about 180 degrees Fahrenheit, to maintain the fluidity of the oil. In Arctic weather, that demands highly effective insulation. General Electric Co.'s Space Division, Valley Forge, Pennsylvania, provided it with a spinoff product called Therm-O-Trol. Shown being installed on the pipeline, Therm-O-Trol is a metal-bonded polyurethane foam especially formulated for Arctic insulation. A second GE spinoff product, Therm-O-Case, solved a related problem involved in bringing hot crude oil from 2,000-foot-deep wells to the surface without transferring oil heat to the surrounding permafrost soil; heat transfer could melt the frozen terrain and cause dislocations that might destroy expensive well casings. Therm-O-Case is a double-walled oil well casing with multi-layered insulation which provides an effective barrier to heat transfer. Therm-O-Trol and Therm-O-Case are members of a family of insulating products which stemmed from technology developed by GE Space Division in heat transferlthermal control work on Gemini, Apollo and other NASA programs.

  10. Peg supported thermal insulation panel

    DOEpatents

    Nowobilski, J.J.; Owens, W.J.

    1985-04-30

    A thermal insulation panel which is lightweight, load bearing, accommodates thermal stress, and has excellent high temperature insulation capability comprises high performance insulation between thin metal walls supported by high density, high strength glass pegs made in compliance with specified conditions of time, temperature and pressure. 2 figs.

  11. Peg supported thermal insulation panel

    DOEpatents

    Nowobilski, Jeffert J.; Owens, William J.

    1985-01-01

    A thermal insulation panel which is lightweight, load bearing, accommodates thermal stress, and has excellent high temperature insulation capability comprising high performance insulation between thin metal walls supported by high density, high strength glass pegs made in compliance with specified conditions of time, temperature and pressure.

  12. High voltage variable diameter insulator

    DOEpatents

    Vanacek, D.L.; Pike, C.D.

    1982-07-13

    A high voltage feedthrough assembly having a tubular insulator extending between the ground plane ring and the high voltage ring. The insulator is made of Pyrex and decreases in diameter from the ground plane ring to the high voltage ring, producing equipotential lines almost perpendicular to the wall of the insulator to optimize the voltage-holding capability of the feedthrough assembly.

  13. Multilayer High-Gradient Insulators

    SciTech Connect

    Harris, J R

    2006-08-16

    Multilayer High-Gradient Insulators are vacuum insulating structures composed of thin, alternating layers of dielectric and metal. They are currently being developed for application to high-current accelerators and related pulsed power systems. This paper describes some of the High-Gradient Insulator research currently being conducted at Lawrence Livermore National Laboratory.

  14. Transcription Independent Insulation at TFIIIC-Dependent Insulators

    PubMed Central

    Valenzuela, Lourdes; Dhillon, Namrita; Kamakaka, Rohinton T.

    2009-01-01

    Chromatin insulators separate active from repressed chromatin domains. In yeast the RNA pol III transcription machinery bound to tRNA genes function with histone acetylases and chromatin remodelers to restrict the spread of heterochromatin. Our results collectively demonstrate that binding of TFIIIC is necessary for insulation but binding of TFIIIB along with TFIIIC likely improves the probability of complex formation at an insulator. Insulation by this transcription factor occurs in the absence of RNA polymerase III or polymerase II but requires specific histone acetylases and chromatin remodelers. This analysis identifies a minimal set of factors required for insulation. PMID:19596900

  15. Accuracy of needle position measurements using fiber Bragg gratings.

    PubMed

    Henken, Kirsten; Van Gerwen, Dennis; Dankelman, Jenny; Van Den Dobbelsteen, John

    2012-11-01

    Accurate placement of the needle tip is essential in percutaneous therapies such as radiofrequency ablation (RFA) of liver tumors. Use of a robotic system for navigating the needle could improve the targeting accuracy. Real-time information on the needle tip position is needed, since a needle deflects during insertion in tissue. Needle shape can be reconstructed based on strain measurements within the needle. In the current experiment we determined the accuracy with which the needle tip position can be derived from strain measurements using Fiber Bragg Gratings (FBGs). Three glass fibers equipped with two FBGs each were incorporated in a needle. The needle was clamped at one end and deformed by applying static radial displacements at one or two locations. The FBG output was used for offline estimation of the needle shape and tip position. During deflections of the needle tip up to 12.5 mm, the tip position was estimated with a mean accuracy of 0.89 mm (std 0.42 mm). Adding a second deflection resulted in an error of 1.32 mm (std 0.48 mm). This accuracy is appropriate for applications such as RFA of liver tumors. The results further show that the accuracy can be improved by optimizing the placement of FBGs. PMID:22455615

  16. The research of knitting needle status monitoring setup

    NASA Astrophysics Data System (ADS)

    Liu, Lu; Liao, Xiao-qing; Zhu, Yong-kang; Yang, Wei; Zhang, Pei; Zhao, Yong-kai; Huang, Hui-jie

    2013-09-01

    In textile production, quality control and testing is the key to ensure the process and improve the efficiency. Defect of the knitting needles is the main factor affecting the quality of the appearance of textiles. Defect detection method based on machine vision and image processing technology is universal. This approach does not effectively identify the defect generated by damaged knitting needles and raise the alarm. We developed a knitting needle status monitoring setup using optical imaging, photoelectric detection and weak signal processing technology to achieve real-time monitoring of weaving needles' position. Depending on the shape of the knitting needle, we designed a kind of Glass Optical Fiber (GOF) light guides with a rectangular port used for transmission of the signal light. To be able to capture the signal of knitting needles accurately, we adopt a optical 4F system which has better imaging quality and simple structure and there is a rectangle image on the focal plane after the system. When a knitting needle passes through position of the rectangle image, the reflected light from needle surface will back to the GOF light guides along the same optical system. According to the intensity of signals, the computer control unit distinguish that the knitting needle is broken or curving. The experimental results show that this system can accurately detect the broken needles and the curving needles on the knitting machine in operating condition.

  17. Integrated Multilayer Insulation

    NASA Technical Reports Server (NTRS)

    Dye, Scott

    2009-01-01

    Integrated multilayer insulation (IMLI) is being developed as an improved alternative to conventional multilayer insulation (MLI), which is more than 50 years old. A typical conventional MLI blanket comprises between 10 and 120 metallized polymer films separated by polyester nets. MLI is the best thermal- insulation material for use in a vacuum, and is the insulation material of choice for spacecraft and cryogenic systems. However, conventional MLI has several disadvantages: It is difficult or impossible to maintain the desired value of gap distance between the film layers (and consequently, it is difficult or impossible to ensure consistent performance), and fabrication and installation are labor-intensive and difficult. The development of IMLI is intended to overcome these disadvantages to some extent and to offer some additional advantages over conventional MLI. The main difference between IMLI and conventional MLI lies in the method of maintaining the gaps between the film layers. In IMLI, the film layers are separated by what its developers call a micro-molded discrete matrix, which can be loosely characterized as consisting of arrays of highly engineered, small, lightweight, polymer (typically, thermoplastic) frames attached to, and placed between, the film layers. The term "micro-molded" refers to both the smallness of the frames and the fact that they are fabricated in a process that forms precise small features, described below, that are essential to attainment of the desired properties. The term "discrete" refers to the nature of the matrix as consisting of separate frames, in contradistinction to a unitary frame spanning entire volume of an insulation blanket.

  18. Mixed mode fuel injector with individually moveable needle valve members

    DOEpatents

    Stewart, Chris; Chockley, Scott A.; Ibrahim, Daniel R.; Lawrence, Keith; Tomaseki, Jay; Azam, Junru H.; Tian, Steven Ye; Shafer, Scott F.

    2004-08-03

    A fuel injector includes a homogenous charge nozzle outlet set and a conventional nozzle outlet set controlled respectively, by first and second needle valve members. One of the needle valve members moves to an open position while the other needle valve member remains stationary for a homogeneous charge injection event. The former needle valve member stays stationary while the other needle valve member moves to an open position for a conventional injection event. One of the needle valve members is at least partially positioned in the other needle valve member. Thus, the injector can perform homogeneous charge injection events, conventional injection events, or even a mixed mode having both types of injection events in a single engine cycle.

  19. Needle phobia: etiology, adverse consequences, and patient management.

    PubMed

    Sokolowski, Chester J; Giovannitti, Joseph A; Boynes, Sean G

    2010-10-01

    Needle phobia has profound health, dental, societal, and legal implications, and severe psychological, social, and physiologic consequences. There is genetic evidence for the physiologic response to needle puncture, and a significant familial psychological component, showing evidence of inheritance. Needle phobia is also a learned behavior. The dental practitioner must recognize patients with needle phobia before the administration of local anesthetics to identify patients who are potentially reactive and to prevent untoward sequelae. Needle phobia is highly associated with avoidance behavior, and the dentist must exhibit compassion and respect. To avoid bradycardia, hypotension, unconsciousness, convulsions, and possibly asystole, oral premedication with benzodiazepines or other antianxiety agents must be considered for patients who are needle phobic. Management of needle phobiaeinduced syncope includes perioperative monitoring, oxygen administration, positioning, atropine, and vasopressors. PMID:20831935

  20. Torsional dynamics of steerable needles: modeling and fluoroscopic guidance.

    PubMed

    Swensen, John P; Lin, MingDe; Okamura, Allison M; Cowan, Noah J

    2014-11-01

    Needle insertions underlie a diversity of medical interventions. Steerable needles provide a means by which to enhance existing needle-based interventions and facilitate new ones. Tip-steerable needles follow a curved path and can be steered by twisting the needle base during insertion, but this twisting excites torsional dynamics that introduce a discrepancy between the base and tip twist angles. Here, we model the torsional dynamics of a flexible rod-such as a tip-steerable needle-during subsurface insertion and develop a new controller based on the model. The torsional model incorporates time-varying mode shapes to capture the changing boundary conditions inherent during insertion. Numerical simulations and physical experiments using two distinct setups-stereo camera feedback in semitransparent artificial tissue and feedback control with real-time X-ray imaging in optically opaque artificial tissue-demonstrate the need to account for torsional dynamics in control of the needle tip. PMID:24860026

  1. An Exploration of the Needling Depth in Acupuncture: The Safe Needling Depth and the Needling Depth of Clinical Efficacy

    PubMed Central

    Lin, Jaung-Geng; Chou, Pei-Chi; Chu, Heng-Yi

    2013-01-01

    Objective. To explore the existing scientific information regarding safe needling depth of acupuncture points and the needling depth of clinical efficacy. Methods. We searched the PubMed, EMBASE, Cochrane, Allied and Complementary Medicine (AMED), The National Center for Complementary and Alternative Medicine (NCCAM), and China National Knowledge Infrastructure (CNKI) databases to identify relevant monographs and related references from 1991 to 2013. Chinese journals and theses/dissertations were hand searched. Results. 47 studies were recruited and divided into 6 groups by measuring tools, that is, MRI, in vivo evaluation, CT, ultrasound, dissected specimen of cadavers, and another group with clinical efficacy. Each research was analyzed for study design, definition of safe depth, and factors that would affect the measured depths. Depths of clinical efficacy were discussed from the perspective of de-qi and other clinical observations. Conclusions. Great inconsistency in depth of each point measured from different subject groups and tools exists. The definition of safe depth should be established through standardization. There is also lack of researches to compare the clinical efficacy. A well-designed clinical trial selecting proper measuring tools to decide the actual and advisable needling depth for each point, to avoid adverse effects or complications and promote optimal clinical efficacy, is a top priority. PMID:23935678

  2. [Needling technique of Professor Li Yan-Fang].

    PubMed

    Li, Li-Jun

    2014-01-01

    Experiences of needling techniques of Professor LI Ya- fang is introduced in this article. Gentle and superficial insertion is adopted by Professor LI in clinic. Emphases are put on the qi regulation function, needling sensation to the affected region and insertion with both hands, especially the function of the left hand as pressing hand. The gentle and superficial insertion should be done as the follows: hold the needle with the right hand, press gently along the running course of meridians with the left hand to promote qi circulation, hard pressing should be applied at acupoints to disperse the local qi and blood, insert the needle gently and quickly into the subcutaneous region with the right hand, and stop the insertion when patient has the needling sensation. While the fast needling is characterized with shallow insertion and swift manipulation: the left hand of the manipulator should press first along the running course of the meridian, and fix the local skin, hold the needle with the right hand and insert the needle quickly into the acupoint. Withdrawal of the needle should be done immediately after the reinforcing and reducing manipulations. Professor LI is accomplished in qi regulation. It is held by him that regulating qi circulation is essence of acupuncture, letting the patient get the needling sensation is the most important task of needling. Lifting, thrusting and rotation manipulations should be applied to do reinforcing or reducing. The tissue around the tip of the needle should not be too contracted or too relaxed, and the resistance should not be too strong or too weak. The feeling of the insertion hand of the practitioner should not be too smooth or too hesitant. Needle should be inserted into the skin quickly at the moment of hard pressing by the left hand. And then, slow rotation and gentle lifting and thrusting can be applied to promote the needling sensation like electric current pass through and to reach the affected region along the

  3. Stacked insulator induction accelerator gaps

    SciTech Connect

    Houck, T.I.; Westenskow, G.A.; Kim, J.S.; Eylon, S.; Henestroza, E.; Yu, S.S.; Vanecek, D.

    1997-05-01

    Stacked insulators, with alternating layers of insulating material and conducting film, have been shown to support high surface electrical field stresses. We have investigated the application of the stacked insulator technology to the design of induction accelerator modules for the Relativistic-Klystron Two-Beam Accelerator program. The rf properties of the accelerating gaps using stacked insulators, particularly the impedance at frequencies above the beam pipe cutoff frequency, are investigated. Low impedance is critical for Relativistic-Klystron Two-Beam Accelerator applications where a high current, bunched beam is trsnsported through many accelerating gaps. An induction accelerator module designs using a stacked insulator is presented.

  4. Multilayer High-Gradient Insulators

    SciTech Connect

    Harris, J R; Anaya, R M; Blackfield, D; Chen, Y -; Falabella, S; Hawkins, S; Holmes, C; Paul, A C; Sampayan, S; Sanders, D M; Watson, J A; Caporaso, G J; Krogh, M

    2006-11-15

    High voltage systems operated in vacuum require insulating materials to maintain spacing between conductors held at different potentials, and may be used to maintain a nonconductive vacuum boundary. Traditional vacuum insulators generally consist of a single material, but insulating structures composed of alternating layers of dielectric and metal can also be built. These ''High-Gradient Insulators'' have been experimentally shown to withstand higher voltage gradients than comparable conventional insulators. As a result, they have application to a wide range of high-voltage vacuum systems where compact size is important. This paper describes ongoing research on these structures, as well as the current theoretical understanding driving this work.

  5. FT Raman spectroscopy of Norway spruce needles

    NASA Astrophysics Data System (ADS)

    Matejka, P.; Pleserova, L.; Budinova, G.; Havirova, K.; Nahlik, J.; Skacel, F.; Volka, Karel

    2001-02-01

    12 Norway spruce [Picea abies (L.) Karst.] needles represent a very useful bioindicator of the air pollution. They serve not only as natural samplers of the pollutants but micromorphology of the epistomatal area can be directly correlated with an environmental stress. The needles of trees growing in polluted areas exhibit different types of injury to the epicuticular wax layer. It is evident that these changes of the morphology of the wax layers are connected also with the changes of their chemical composition and so a potential of the FT Raman spectroscopy was tested to serve as a screening method of these changes. In this work variability of the spectra with the age and with the position in the tree, in the locality, and also in the different localities of the Czech Republic was studied and evaluated in comparison with results of electron scanning microscopy.

  6. Maxillofacial Changes in Melnick-Needles Syndrome

    PubMed Central

    Albuquerque do Nascimento, Leilane Larissa; Salgueiro, Monica da Consolação Canuto; Quintela, Mariana; Mota, Ana Carolina Costa

    2016-01-01

    Background. Melnick-Needles Syndrome is rare congenital hereditary skeletal dysplasia caused by mutations in the FLNA gene, which codifies the protein filamin A. This condition leads to serious skeletal abnormalities, including the stomatognathic region. Case Presentation. This paper describes the case of a 13-year-old girl diagnosed with Melnick-Needles Syndrome presenting with different forms of skeletal dysplasia, such as cranial hyperostosis, short upper limbs, bowed long bones, metaphyseal thickening, genu valgum (knock-knee), shortened distal phalanges, narrow pelvis and shoulders, rib tapering and irregularities, elongation of the vertebrae, kyphoscoliosis, micrognathia, hypoplastic coronoid processes of the mandible, left stylohyoid ligament suggesting ossification, and dental development anomalies. Conclusion. Knowledge of this rare syndrome on the part of dentists is important due to the fact that this condition involves severe abnormalities of the stomatognathic system that cause an impact on the development of the entire face as well as functional and esthetic impairments. PMID:27478655

  7. Maxillofacial Changes in Melnick-Needles Syndrome.

    PubMed

    Albuquerque do Nascimento, Leilane Larissa; Salgueiro, Monica da Consolação Canuto; Quintela, Mariana; Teixeira, Victor Perez; Mota, Ana Carolina Costa; de Godoy, Camila Haddad Leal; Bussadori, Sandra Kalil

    2016-01-01

    Background. Melnick-Needles Syndrome is rare congenital hereditary skeletal dysplasia caused by mutations in the FLNA gene, which codifies the protein filamin A. This condition leads to serious skeletal abnormalities, including the stomatognathic region. Case Presentation. This paper describes the case of a 13-year-old girl diagnosed with Melnick-Needles Syndrome presenting with different forms of skeletal dysplasia, such as cranial hyperostosis, short upper limbs, bowed long bones, metaphyseal thickening, genu valgum (knock-knee), shortened distal phalanges, narrow pelvis and shoulders, rib tapering and irregularities, elongation of the vertebrae, kyphoscoliosis, micrognathia, hypoplastic coronoid processes of the mandible, left stylohyoid ligament suggesting ossification, and dental development anomalies. Conclusion. Knowledge of this rare syndrome on the part of dentists is important due to the fact that this condition involves severe abnormalities of the stomatognathic system that cause an impact on the development of the entire face as well as functional and esthetic impairments. PMID:27478655

  8. Needle tip localization using stylet vibration.

    PubMed

    Harmat, Adam; Rohling, Robert N; Salcudean, Septimiu E

    2006-09-01

    Power Doppler ultrasound is used to localize the tip of a needle by detecting physical vibrations. Two types of vibrations are investigated, lateral and axial. The lateral vibrations are created by rotating a stylet, whose tip is slightly bent, inside a stationary cannula while the stylet is completely within the cannula. The minute deflection at the needle tip when rotated causes tissue motion. The axial vibration is induced by extending and retracting a straight stylet inside a stationary cannula. The stylet's tip makes contact with the tissue and causes it to move. The lateral vibration method was found to perform approximately the same under a variety of configurations (e.g., different insertion angles and depths) and better than the axial vibration method. Tissue stiffness affects the performance of the lateral vibration method, but good images can be obtained through proper tuning of the ultrasound machine. PMID:16965974

  9. Skinny needle pyelography. An advance in uroradiology.

    PubMed

    Hare, W S; McOmish, D

    1981-08-01

    Diagnostic puncture of the renal pelvis with a fine-gauge needle inserted under radiological and ultrasound control, has been performed in more than 100 cases. The method is safe, easy to perform for those trained in imaging modalities, and causes little discomfort. Pyelography and pressure flow studies can be made and urine specimens obtained from the upper urinary tract. Skinny needle pyelography is indicated in unilateral non-visualization of the ureter on intravenous pyelography, in acute oliguric renal failure when ultrasound reveals dilated ureters, and when retrograde pyelography is not feasible. The method is cost-effective, as it can be performed on outpatients as a follow-on procedure after intravenous pyelography or renal ultrasound scanning. PMID:7026995

  10. Fine needle aspiration cytology of gastric carcinoma.

    PubMed Central

    Allen, D. C.; Irwin, S. T.

    1997-01-01

    Four patients between 58 and 81 years of age undergoing investigation and endoscopic biopsy for gastric carcinoma also were subjected to direct-vision fine needle aspiration cytology of their mucosal lesions which yielded malignant cells. The relevance of this technique is discussed regarding both intrinsic and extrinsic lesions of the gastrointestinal tract. Images Fig 1. (a) Fig 1. (b) Fig 2. (a) Fig 2. (b) PMID:9414941