Science.gov

Sample records for iodine contrast agent

  1. Frequently asked questions: iodinated contrast agents.

    PubMed

    Bettmann, Michael A

    2004-10-01

    Although iodinated contrast agents are safe and widely used, adverse events occur and questions remain about their use, safety, and interactions. Some questions are easily answered and others still require extensive investigation. For one frequent question--is informed consent necessary before all contrast media injections--the simple answer is no. Another question concerns use of contrast media in patients with prior reactions or allergies. Contrast agents can be safely used in such patients, but special care must be taken to be aware of what the previous reaction was and to be ready to treat any reaction. The protective role of pre-treatment with steroids is well established for minor reactions, but they may not prevent major reactions. It is important to realize that even life-threatening, anaphylactoid reactions are not the result of a true allergy to contrast media. Many questions arise about contrast agent-induced nephropathy. Baseline serum creatinine values should be obtained in patients who are at risk, not all patients. The incidence and natural history of contrast agent-induced nephropathy remain unclear. It occurs only in patients with compromised renal function before contrast agent injection, but even patients with normal serum creatinine levels can have renal dysfunction. Calculated creatinine clearance is a better way to determine risk and to follow this complication. The outcome in almost all patients is benign, with progression to end-stage renal disease being rare. The major risk factors, in addition to renal dysfunction, are long-standing diabetes mellitus, dehydration, and use of other nephrotoxic medications. Recent work in preventing and ameliorating contrast agent-induced nephropathy with N-acetyl cysteine, substitution of an isosmolal nonionic contrast agent, and various hydration regimens has been promising. Another common concern is use of iodinated contrast agents in pregnant or breast-feeding women. In both cases, there is no evidence

  2. [Iodinated contrast agents used in Radiology].

    PubMed

    Ramírez Ribelles, C; Sánchez Fuster, M A; Pamies Guilabert, J

    2014-06-01

    Iodinated contrast media are widely used in Radiology practices with a very low rate of adverse effects, being contrast-induced nephropathy the most serious one. In the majority of cases it is temporary and reversible, even though it can increase the inhospital morbidity and mortality in patients with risk factors. We will describe the various measures of prevention, being hydration and use of non-ionic contrast low osmolality those which have demonstrated greater effectiveness. Precautions to be taken in some risk situations, as patients treated with metformin or with impaired renal function, are also discussed. PMID:25267147

  3. Biodegradable Iodinated Polydisulfides as Contrast Agents for CT Angiography

    PubMed Central

    Jin, Erlei; Zheng-Rong, Lu

    2014-01-01

    Current clinical CT contrast agents are mainly small molecular iodinated compounds, which often suffer from short blood pool retention for more comprehensive cardiovascular CT imaging and may cause contrast-induced nephropathy. In this work, we prepared polydisulfides containing a traditional iodinated CT contrast agent in order to optimize the pharmacokinetics of the agent and improve its safety. Initially acting as a macromolecular agent and achieving sharp blood vessel delineation, the polydisulfides can be reduced by endogenous thiols via disulfide-thiol exchange reaction to oligomers that can be readily excreted via renal filtration. Short polyethylene glycol (PEG) chain was also introduced to the polymers to further modify the in vivo properties of the agents. Strong and prolonged vascular enhancement has been generated with two new agents in mice (5–10 times higher blood pool enhancement than iodinaxol). The polydisulfide agents gradually degraded and excreted via renal filtration. The gradual excretion process could prevent contrast induced nephropathy. These results suggest that the biodegradable macromolecular CT contrast agents are promising safe and effective blood contrast agents for CT angiography and image-guided interventions. PMID:24768156

  4. [Immediate allergy to iodinated contrast agents and prevention of reactions].

    PubMed

    Dewachter, P; Mouton-Faivre, C; Laroche, D; Clément, O

    2009-10-01

    The incidence and morbimortality of immediate hypersensitivity reactions following iodinated contrast media (ICM) injection remain unknown. The diagnosis of an immediate hypersensitivity reaction relies on a triad associating the precise description of the initial clinical manifestations and their delay of onset, the results of the biological assessment performed after the reaction including histamine and tryptase serum level measurements, and the results of skin testing with the culprit agent. Analysis of these data allows identification of the pathophysiologic mechanism of the reaction and the allergen involved in case of allergic hypersensitivity. Skin tests should be performed according to strict criteria. Cross-reactivity with ICM has to be investigated in order to propose a nonreactive ICM for future procedures. Allergic hypersensitivity to a given ICM imposes its definitive avoidance but not the avoidance of all iodinated drugs. The allergenic sequence has not yet been identified but is not the iodine atom itself. Asthma and treatment with beta-blockers are not risk factors of immediate allergic reactions to ICM per se, but may increase their severity. The various published protocols of premedication do not prevent the occurrence of an allergic/anaphylactic reaction to an ICM. The avoidance of the culprit ICM is the only way to prevent further reactions. PMID:19375199

  5. Characterization of liposomes containing iodine-125-labeled radiographic contrast agents

    SciTech Connect

    Zalutsky, M.R.; Noska, M.A.; Seltzer, S.E.

    1987-02-01

    Multilamellar liposomes were prepared containing either iodine-125-labeled (/sup 125/I) diatrizoate or /sup 125/I labeled iotrol in their aqueous phase. The in vitro permeabilities of liposomes containing both contrast agents were measured in the presence of saline and serum at 37 degrees C. Two different phospholipid compositions were studied: phosphatidylcholine/cholesterol/stearylamine (PC/C/S, 8: 1:1 molar ratio) and distearoylphosphatidylcholine/sphingomyelin (DSPC/SM, 5:2 mole ratio). In saline, similar permeabilities were observed for the four phospholipid-contrast agent combinations. In serum, however, leakage of /sup 125/I activity was 2 to 3 times greater from PC/C/S liposomes than from vesicles composed of DSPC/SM. When PC/C/S liposomes that contained /sup 125/I-diatrizoate were injected into rats, the clearance half-times for /sup 125/I activity from the liver, spleen, and whole body were 4.4 hours, 4.5 hours, and 2.8 hours, respectively. Liposomes composed of DSPC/SM cleared at a significantly slower rate from the liver, spleen, and whole body with half-times of 24.0 hours, 18.4 hours, and 17.2 hours observed from these tissues, respectively.

  6. Synthesis and characterization of ethosomal contrast agents containing iodine for computed tomography (CT) imaging applications.

    PubMed

    Shin, Hanjin; Cho, Young-Min; Lee, Kangtaek; Lee, Chang-Ha; Choi, Byoung Wook; Kim, Bumsang

    2014-06-01

    As a first step in the development of novel liver-specific contrast agents using ethosomes for computed tomography (CT) imaging applications, we entrapped iodine within ethosomes, which are phospholipid vesicular carriers containing relatively high alcohol concentrations, synthesized using several types of alcohol, such as methanol, ethanol, and propanol. The iodine containing ethosomes that were prepared using methanol showed the smallest vesicle size (392 nm) and the highest CT density (1107 HU). The incorporation of cholesterol into the ethosomal contrast agents improved the stability of the ethosomes but made the vesicle size large. The ethosomal contrast agents were taken up well by macrophage cells and showed no cellular toxicity. The results demonstrated that ethosomes containing iodine, as prepared in this study, have potential as contrast agents for applications in CT imaging. PMID:24188576

  7. [Immediate and delayed hypersensitivity reactions to iodinated radiographic contrast agents: an update].

    PubMed

    Khachman, Dalia; Gandia, Peggy; Sallerin, François; Mailly, Nicolas

    2009-01-01

    Diagnostic and interventional radiology of patients is nowadays crucial with increasing requirement for iodinated contrast agents infusion. Besides adverse reactions after administration of the iodinated contrast agents due to their toxicity, immediate hypersensitivity reactions and reactions resembling delayed hypersensitivity appearing from 1 hour to several days later, have been reported. Patients at high risk to develop such adverse events have to be detected on the basis of their risk factors in order to prevent or limit serious outcomes. Previous reactions to contrast media, asthma, atopy and cardiovascular disorders are risk factors for anaphylactic or anaphylactoid reactions. Female gender, age and beta-blockers increase the severity. This article aims to summarize the risk of allergic reactions related to the use of iodinated contrast agents and to suggest a way for diagnosis, treatment and prevention according to each clinical situation. PMID:19863909

  8. Experimental and theoretical x-ray imaging performance comparison of iodine and lanthanide contrast agents.

    PubMed

    Cardinal, H N; Holdsworth, D W; Drangova, M; Hobbs, B B; Fenster, A

    1993-01-01

    Contrast agents based on the lanthanide elements gadolinium and holmium have recently been developed for magnetic resonance imaging (MRI). Because of the increased atomic number of these elements relative to iodine, these new compounds, used as x-ray contrast agents, may yield higher radiographic contrast, and hence improved x-ray image quality, relative to conventional iodinated compounds, for clinically useful x-ray spectra. This possibility has been investigated, in independent experimental and theoretical studies, for two x-ray imaging systems: a digital radiographic system, using an x-ray image intensifier (XRII) and charge-coupled device (CCD) detector; and a conventional screen/film system, using a Lanex Regular screen. Iodine, gadolinium, and holmium contrast agents were investigated over a wide range of concentration-thickness products (0.1-0.6 M cm) and diagnostic x-ray spectra (60-120 kVp). A simple theoretical model of x-ray detector response predicts the experimental radiographic contrast measurements with a mean absolute error of 8.0% for the XRII/CCD system and 5.9% for the screen/film system, and shows that the radiographic contrast for these two systems is representative of all XRII and screen/film systems. An index of image quality is defined, and its dependence on radiographic contrast, x-ray fluence per unit dose, and detective quantum efficiency (DQE) is shown. Theoretical values of the index, predicted by our model, are then used to compare the performance of the three contrast agents for the two systems investigated. In general, iodine performance decreases steadily with increasing kVp, gadolinium performance has a broad maximum near 85 kVp, and gadolinium outperforms holmium. Gadolinium outperforms iodine for spectra above (and vice versa below) about 72 kVp, depending slightly on spectrum filtration, object thickness, and detector type. Thus, raising the kVp to shorten exposure times or reduce x-ray tube heat loading results in a loss of

  9. Absolute perfusion measurements and associated iodinated contrast agent time course in brain metastasis: a study for contrast-enhanced radiotherapy

    PubMed Central

    Obeid, Layal; Deman, Pierre; Tessier, Alexandre; Balosso, Jacques; Estève, François; Adam, Jean- François

    2014-01-01

    Contrast-enhanced radiotherapy is an innovative treatment that combines the selective accumulation of heavy elements in tumors with stereotactic irradiations using medium energy X-rays. The radiation dose enhancement depends on the absolute amount of iodine reached in the tumor and its time course. Quantitative, postinfusion iodine biodistribution and associated brain perfusion parameters were studied in human brain metastasis as key parameters for treatment feasibility and quality. Twelve patients received an intravenous bolus of iodinated contrast agent (CA) (40 mL, 4 mL/s), followed by a steady-state infusion (160 mL, 0.5 mL/s) to ensure stable intratumoral amounts of iodine during the treatment. Absolute iodine concentrations and quantitative perfusion maps were derived from 40 multislice dynamic computed tomography (CT) images of the brain. The postinfusion mean intratumoral iodine concentration (over 30 minutes) reached 1.94±0.12 mg/mL. Reasonable correlations were obtained between these concentrations and the permeability surface area product and the cerebral blood volume. To our knowledge, this is the first quantitative study of CA biodistribution versus time in brain metastasis. The study shows that suitable and stable amounts of iodine can be reached for contrast-enhanced radiotherapy. Moreover, the associated perfusion measurements provide useful information for the patient recruitment and management processes. PMID:24447951

  10. MCNP simulation of absorbed energy and dose by iodinated contrast agent

    NASA Astrophysics Data System (ADS)

    He, Wenjun; Mah, Eugene; Huda, Walter; Yao, Hai

    2012-03-01

    The purpose of this study is to investigate the absorbed dose and energy by iodinated contrast medium in diagnostic radiology. A simulation geometry in which an inner sphere (d = 0.2cm, 1cm, 5cm) filled with iodinated contrast medium (or water) is located at the center of a 20cm diameter water sphere was used in simulations performed with MCNP5 codes. Monoenergetic x-rays with energies ranging from 40 to 80keV from a cone beam source were utilized and contrast medium concentration ranged from 100 to 1mg/ml. Absorbed dose ratio (RD) to inner sphere and total absorbed energies ratio (RE) to the whole phantom with and without iodinated contrast medium were investigated. The maximum RD was ~13 for the 0.2cm diameter sphere with 100mg/ml contrast medium. The maximum RE was ~1.05 for the 5cm diameter contrast sphere at 80keV with 100mg/ml contrast medium. Under the same incident photon energy, increasing the inner sphere size from 0.2cm to 5cm caused a ~63% increase in the RD on average. Decreasing the contrast medium concentration from 100 to 10 mg/ml caused a decrease of RD of ~ 76%. A conclusion was reached that although local absorbed dose increase caused by iodinated contrast agent could be high; the increase in total absorbed energy is negligible.

  11. Improved sensitivity of computed tomography towards iodine and gold nanoparticle contrast agents via iterative reconstruction methods

    NASA Astrophysics Data System (ADS)

    Bernstein, Ally Leigh; Dhanantwari, Amar; Jurcova, Martina; Cheheltani, Rabee; Naha, Pratap Chandra; Ivanc, Thomas; Shefer, Efrat; Cormode, David Peter

    2016-05-01

    Computed tomography is a widely used medical imaging technique that has high spatial and temporal resolution. Its weakness is its low sensitivity towards contrast media. Iterative reconstruction techniques (ITER) have recently become available, which provide reduced image noise compared with traditional filtered back-projection methods (FBP), which may allow the sensitivity of CT to be improved, however this effect has not been studied in detail. We scanned phantoms containing either an iodine contrast agent or gold nanoparticles. We used a range of tube voltages and currents. We performed reconstruction with FBP, ITER and a novel, iterative, modal-based reconstruction (IMR) algorithm. We found that noise decreased in an algorithm dependent manner (FBP > ITER > IMR) for every scan and that no differences were observed in attenuation rates of the agents. The contrast to noise ratio (CNR) of iodine was highest at 80 kV, whilst the CNR for gold was highest at 140 kV. The CNR of IMR images was almost tenfold higher than that of FBP images. Similar trends were found in dual energy images formed using these algorithms. In conclusion, IMR-based reconstruction techniques will allow contrast agents to be detected with greater sensitivity, and may allow lower contrast agent doses to be used.

  12. Improved sensitivity of computed tomography towards iodine and gold nanoparticle contrast agents via iterative reconstruction methods

    PubMed Central

    Bernstein, Ally Leigh; Dhanantwari, Amar; Jurcova, Martina; Cheheltani, Rabee; Naha, Pratap Chandra; Ivanc, Thomas; Shefer, Efrat; Cormode, David Peter

    2016-01-01

    Computed tomography is a widely used medical imaging technique that has high spatial and temporal resolution. Its weakness is its low sensitivity towards contrast media. Iterative reconstruction techniques (ITER) have recently become available, which provide reduced image noise compared with traditional filtered back-projection methods (FBP), which may allow the sensitivity of CT to be improved, however this effect has not been studied in detail. We scanned phantoms containing either an iodine contrast agent or gold nanoparticles. We used a range of tube voltages and currents. We performed reconstruction with FBP, ITER and a novel, iterative, modal-based reconstruction (IMR) algorithm. We found that noise decreased in an algorithm dependent manner (FBP > ITER > IMR) for every scan and that no differences were observed in attenuation rates of the agents. The contrast to noise ratio (CNR) of iodine was highest at 80 kV, whilst the CNR for gold was highest at 140 kV. The CNR of IMR images was almost tenfold higher than that of FBP images. Similar trends were found in dual energy images formed using these algorithms. In conclusion, IMR-based reconstruction techniques will allow contrast agents to be detected with greater sensitivity, and may allow lower contrast agent doses to be used. PMID:27185492

  13. Improved sensitivity of computed tomography towards iodine and gold nanoparticle contrast agents via iterative reconstruction methods.

    PubMed

    Bernstein, Ally Leigh; Dhanantwari, Amar; Jurcova, Martina; Cheheltani, Rabee; Naha, Pratap Chandra; Ivanc, Thomas; Shefer, Efrat; Cormode, David Peter

    2016-01-01

    Computed tomography is a widely used medical imaging technique that has high spatial and temporal resolution. Its weakness is its low sensitivity towards contrast media. Iterative reconstruction techniques (ITER) have recently become available, which provide reduced image noise compared with traditional filtered back-projection methods (FBP), which may allow the sensitivity of CT to be improved, however this effect has not been studied in detail. We scanned phantoms containing either an iodine contrast agent or gold nanoparticles. We used a range of tube voltages and currents. We performed reconstruction with FBP, ITER and a novel, iterative, modal-based reconstruction (IMR) algorithm. We found that noise decreased in an algorithm dependent manner (FBP > ITER > IMR) for every scan and that no differences were observed in attenuation rates of the agents. The contrast to noise ratio (CNR) of iodine was highest at 80 kV, whilst the CNR for gold was highest at 140 kV. The CNR of IMR images was almost tenfold higher than that of FBP images. Similar trends were found in dual energy images formed using these algorithms. In conclusion, IMR-based reconstruction techniques will allow contrast agents to be detected with greater sensitivity, and may allow lower contrast agent doses to be used. PMID:27185492

  14. Determination of free iodine concentration in an X-ray contrast agent

    NASA Astrophysics Data System (ADS)

    Kljubin, V. V.; Kljubina, K. A.; Makovetskaya, K. N.

    2016-04-01

    Based on the analysis of the absorption spectra of solutions of iodine in ethanol, we propose a simple and sensitive (at a level of 1 μg/g) method for determination of the concentration of free (not bound to polymer) iodine in substances synthesized from ether oils and iodine. The method uses absorption of molecular iodine in the UV region. Iodine dissolved in alcohols has a rather large absorption cross section in the UV region. These absorption bands can be used to detect very small quantities of iodine. It is shown that, for iodine concentrations in the 1-50 μg/g range, the intensity of absorption band at a wavelength of 359 nm depends linearly on the iodine concentration, which allows one to use this band to determine the concentration of iodine not bound with the polymer in the X-ray contrast material.

  15. The study of N-isopropylacrylamide gel dosimeter doped iodinated contrast agents

    NASA Astrophysics Data System (ADS)

    Chang, Y. J.; Hsieh, L. L.; Liu, M. H.; Liu, J. S.; Hsieh, B. T.

    2013-06-01

    Low toxicity of N-isopropylacrylamide (NIPAM) dosimeter was doped with clinical iodinated contrast medium agents(Iobitridol (Xenetix® 350) and organically bound iodine (Conray® 60) as radiation sensitizers; The suitable gel dosimeter preparation formula in this research was 5 w/w% gelatin, 5 w/w% N-isopropylacrylamide, 3 w/w% N,N-methylene-bis-acrylamide, and 5 mM Tetrakis phosphonium chloride. The spiral CT was irradiator, and 120 kVp was the operating tube voltage. The maximum radiation dose was 0.6 Gy, and optical CT was the gel measurement device used. The results showed SERs with the addition of radiosensitizers were 10.70 (Xenetix® 350) and 9.67 (Conray® 60), respectively. Thus, the polymerized gel dosimeter could be used in the efficacy evaluation of low-energy and low-radiation dose.

  16. Effects of iodinated contrast agent, xylocaine and gadolinium concentration on the signal emitted in magnetic resonance arthrography: a samples study*

    PubMed Central

    da Silva, Yvana Lopes Pinheiro; Costa, Rita Zanlorensi Visneck; Pinho, Kátia Elisa Prus; Ferreira, Ricardo Rabello; Schuindt, Sueliton Miyamoto

    2015-01-01

    Objective To investigate the effects of dilution of paramagnetic contrast agent with iodinated contrast and xylocaine on the signal intensity during magnetic resonance arthrography, and to improve the paramagnetic contrast agent concentration utilized in this imaging modality. Materials and Methods Samples specially prepared for the study with three different concentrations of paramagnetic contrast agent diluted in saline, iodinated contrast agent and xylocaine were imaged with fast spin echo T1-weighted sequences with fat saturation. The samples were placed into flasks and graphical analysis of the signal intensity was performed as a function of the paramagnetic contrast concentration. Results As compared with samples of equal concentrations diluted only with saline, the authors have observed an average signal intensity decrease of 20.67% for iodinated contrast agent, and of 28.34% for xylocaine. However, the increased gadolinium concentration in the samples caused decrease in signal intensity with all the dilutions. Conclusion Minimizing the use of iodinated contrast media and xylocaine and/or the use of a gadolinium concentration of 2.5 mmol/L diluted in saline will improve the sensitivity of magnetic resonance arthrography. PMID:25987746

  17. [Immediate hypersensitivity reactions to iodinated contrast agents used in radiology: a review].

    PubMed

    Moussa, Lina Menassa; Nabhane, Linda; Smayra, Tarek; Zebouni, Soha Haddad; Mohanna, Assaad; Abi Khalil, Samer; Aoun, Noel

    2012-01-01

    The use of iodinated contrast agents (IC) has become common practice nowadays in the daily diagnostic and therapeutic procedures in radiology. Immediate hypersensitivity reactions occurring up to the first hour after injection of IC, can be of serious consequences, occasionally leading to death. This justifies the establishment of a prevention algorithm, including a sharp identification of those at risk and the implementation of premedication with corticosteroids. A history of previous reaction to IC is the major risk factor of a new reaction. Other risk factors include asthma, atopy and cardiomyopathy. The factors that influence the severity of the hypersensitivity allergic reactions are female gender, age, and taking beta blockers or ACE inhibitor drugs. PMID:23198457

  18. In vivo comparison of tantalum, tungsten, and bismuth enteric contrast agents to complement intravenous iodine for double-contrast dual-energy CT of the bowel.

    PubMed

    Rathnayake, Samira; Mongan, John; Torres, Andrew S; Colborn, Robert; Gao, Dong-Wei; Yeh, Benjamin M; Fu, Yanjun

    2016-07-01

    To assess the ability of dual-energy CT (DECT) to separate intravenous contrast of bowel wall from intraluminal contrast, we scanned 16 rabbits on a clinical DECT scanner: n = 3 using only iodinated intravenous contrast, and n = 13 double-contrast enhanced scans using iodinated intravenous contrast and experimental enteric non-iodinated contrast agents in the bowel lumen (five bismuth, four tungsten, and four tantalum based). Representative image pairs from conventional CT images and DECT iodine density maps of small bowel (116 pairs from 232 images) were viewed by four abdominal imaging attending radiologists to independently score each comparison pair on a visual analog scale (-100 to +100%) for (1) preference in small bowel wall visualization and (2) preference in completeness of intraluminal enteric contrast subtraction. Median small bowel wall visualization was scored 39 and 42 percentage points (95% CI 30-44% and 36-45%, both p < 0.001) higher for double-contrast DECT than for conventional CT with enteric tungsten and tantalum contrast, respectively. Median small bowel wall visualization for double-contrast DECT was scored 29 and 35 percentage points (95% CI 20-35% and 33-39%, both p < 0.001) higher with enteric tungsten and tantalum, respectively, than with bismuth contrast. Median completeness of intraluminal enteric contrast subtraction in double-contrast DECT iodine density maps was scored 28 and 29 percentage points (95% CI 15-31% and 28-33%, both p < 0.001) higher with enteric tungsten and tantalum, respectively, than with bismuth contrast. Results suggest that in vivo double-contrast DECT with iodinated intravenous and either tantalum- or tungsten-based enteric contrast provides better visualization of small bowel than conventional CT. Copyright © 2016 John Wiley & Sons, Ltd. PMID:26892945

  19. Iodinated α-tocopherol nano-emulsions as non-toxic contrast agents for preclinical X-ray imaging.

    PubMed

    Li, Xiang; Anton, Nicolas; Zuber, Guy; Zhao, Minjie; Messaddeq, Nadia; Hallouard, François; Fessi, Hatem; Vandamme, Thierry F

    2013-01-01

    Micro-computed tomography (micro-CT) is an emerging imaging modality, due to the low cost of the imagers as well as their efficiency in establishing high-resolution (1-100 μm) three-dimensional images of small laboratory animals and facilitating rapid, structural and functional in vivo visualization. However use of a contrast agent is absolutely necessary when imaging soft tissues. The main limitation of micro-CT is the low efficiency and toxicity of the commercially available blood pool contrast agents. This study proposes new, efficient and non-toxic contrast agents for micro-CT imaging. This formulation consists of iodinated vitamin E (α-tocopheryl 2,3,5-triiodobenzoate) as an oily phase, formulated as liquid nano-emulsion droplets (by low-energy nano-emulsification), surrounded by a hairy PEG layer to confer stealth properties. The originality and strength of these new contrast agents lie not only in their outstanding contrasting properties, biocompatibility and low toxicity, but also in the simplicity of their fabrication: one-step synthesis of highly iodinated oil (iodine constitutes 41.7% of the oil molecule weight) and its spontaneous emulsification. After i.v. administration in mice (8.5% of blood volume), the product shows stealth properties towards the immune system and thus acts as an efficient blood pool contrast agent (t(1/2) = 9.0 h), exhibiting blood clearance following mono-exponential decay. A gradual accumulation predominantly due to hepatocyte uptake is observed and measured in the liver, establishing a strong hepatic contrast, persistent for more than four months. To summarize, in the current range of available or developed contrast agents for preclinical X-ray imaging, this agent appears to be one of the most efficient. PMID:23083930

  20. Investigation of the use of iodinated contrast agent in a proposed flat-panel CT mammography system

    NASA Astrophysics Data System (ADS)

    Didier, Clay; Glick, Stephen; Gong, Xing; Chen, Yu; Mahd, Mufeed

    2007-03-01

    In considering a breast CT system, it is important to note that the spectral attenuation profile of a tumor is very similar to that of fibro-glandular tissue. Preliminary evidence based on imaging breast specimens suggest that the CT number of a malignant breast tumor is very similar to that of surrounding fibro-glandular tissue. Therefore, it is expected that radiologists will probably rely more on tumor morphology to distinguish a malignant tumor from fibro-glandular tissue than an increase in contrast per se. Previous studies have shown that iodinated contrast agents can increase the effective attenuation coefficient yielded by a breast tumor thereby providing increased CT tumor contrast. In order to characterize how the intravenous administration of an iodinated contrast agent can affect the performance of CT breast imaging, a computer simulation of such a system was conducted. The two primary goals of this investigation were first to determine how mean glandular dose, choice of x-ray energy spectrum, and iodine contrast agent density affect tumor detection, and second to determine what effect Compton and Rayleigh scattering have on the variability of the attenuation coefficient yielded by CT mammography. The first goal was achieved by making use of a modified version of the Bakic (Med. Phys. 2003) digital breast phantom to model the uncompressed breast, and a 0.5 cm sphere representing a breast tumor was digitally inserted into the ductal region of this phantom. Several projection sets were generated with the tumor containing various densities of iodine contrast agent, different x-ray energy spectra, and different mean glandular dosage (MGD) levels . Slices through the tumor were extracted from the reconstructions of these projections and were used in human observer studies to determine tumor detectability. The second goal was achieved by using the GATE (Geant 4 Application for Tomographic Emission) Monte-Carlo software package to compute the scattering

  1. Arterial double-contrast dual-energy MDCT: in-vivo rabbit atherosclerosis with iodinated nanoparticles and gadolinium agents

    NASA Astrophysics Data System (ADS)

    Carmi, Raz; Kafri, Galit; Altman, Ami; Goshen, Liran; Planer, David; Sosna, Jacob

    2010-03-01

    An in-vivo feasibility study of potentially improved atherosclerosis CT imaging is presented. By administration of two different contrast agents to rabbits with induced atherosclerotic plaques we aim at identifying both soft plaque and vessel lumen simultaneously. Initial injection of iodinated nanoparticle (INP) contrast agent (N1177 - Nanoscan Imaging), two to four hours before scan, leads to its later accumulation in macrophage-rich soft plaque, while a second gadolinium contrast agent (Magnevist) injected immediately prior to the scan blends with the aortic blood. The distinction between the two agents in a single scan is achieved with a double-layer dual-energy MDCT (Philips Healthcare) following material separation analysis using the reconstructed images of the different x-ray spectra. A single contrast agent injection scan, where only INP was injected two hours prior to the scan, was compared to a double-contrast scan taken four hours after INP injection and immediately after gadolinium injection. On the single contrast agent scan we observed along the aorta walls, localized iodine accumulation which can point on INP uptake by atherosclerotic plaque. In the double-contrast scan the gadolinium contributes a clearer depiction of the vessel lumen in addition to the lasting INP presence. The material separation shows a good correlation to the pathologies inferred from the conventional CT images of the two different scans while performing only a single scan prevents miss-registration problems and reduces radiation dose. These results suggest that a double-contrast dual-energy CT may be used for advanced clinical diagnostic applications.

  2. Environmental risk assessment for the widely used iodinated X-ray contrast agent iopromide (Ultravist).

    PubMed

    Steger-Hartmann, T; Länge, R; Schweinfurth, H

    1999-03-01

    Iodinated X-ray contrast media are diagnostic pharmaceuticals that are applied to enhance the contrast between organs or vessels examined and surrounding tissues during radiography. These substances are applied in doses up to ca. 200 g per person (corresponding to approx 100 g iodine) and are rapidly excreted. In the sewage system they contribute to the burden of adsorbable organic halogens (AOX). To assess the potential environmental impact of this release, studies on environmental fate and effects were conducted for a risk assessment of the frequently used X-ray contrast medium iopromide (brand name: Ultravist). A screening test for biological degradation (OECD Screening Test 301 E) led to iopromide being classified as not readily biodegradable. Therefore, the predicted environmental concentration (PEC) in surface water was calculated in a first step. The resulting concentration of 2 microgram/liter was then compared in a second step with the predicted no-effect concentration as derived from a battery of ecotoxicity tests. In short-term toxicity tests with bacteria (Vibrio fisheri, Pseudomonas putida), algae (Scenedesmus subspicatus), crustaceans (Daphnia magna), and fish (Danio rerio, Leuciscus idus) no toxic effects were detected at the highest tested concentration of 10 g/liter. In a chronic toxicity test with D. magna no effect was observed at the highest tested concentration of 1 g/liter. Using an assessment factor of 100 the ratio between the predicted environmental concentration (PEC) and the predicted no-effect concentration (PNEC) was calculated to be

  3. Computed Tomography Imaging of Solid Tumors Using a Liposomal-Iodine Contrast Agent in Companion Dogs with Naturally Occurring Cancer

    PubMed Central

    Ghaghada, Ketan B.; Sato, Amy F.; Starosolski, Zbigniew A.; Berg, John; Vail, David M.

    2016-01-01

    Objectives Companion dogs with naturally occurring cancer serve as an important large animal model in translational research because they share strong similarities with human cancers. In this study, we investigated a long circulating liposomal-iodine contrast agent (Liposomal-I) for computed tomography (CT) imaging of solid tumors in companion dogs with naturally occurring cancer. Materials and Methods The institutional animal ethics committees approved the study and written informed consent was obtained from all owners. Thirteen dogs (mean age 10.1 years) with a variety of masses including primary and metastatic liver tumors, sarcomas, mammary carcinoma and lung tumors, were enrolled in the study. CT imaging was performed pre-contrast and at 15 minutes and 24 hours after intravenous administration of Liposomal-I (275 mg/kg iodine dose). Conventional contrast-enhanced CT imaging was performed in a subset of dogs, 90 minutes prior to administration of Liposomal-I. Histologic or cytologic diagnosis was obtained for each dog prior to admission into the study. Results Liposomal-I resulted in significant (p < 0.05) enhancement and uniform opacification of the vascular compartment. Non-renal, reticulo-endothelial systemic clearance of the contrast agent was demonstrated. Liposomal-I enabled visualization of primary and metastatic liver tumors. Sub-cm sized liver lesions grossly appeared as hypo-enhanced compared to the surrounding normal parenchyma with improved lesion conspicuity in the post-24 hour scan. Large liver tumors (> 1 cm) demonstrated a heterogeneous pattern of intra-tumoral signal with visibly higher signal enhancement at the post-24 hour time point. Extra-hepatic, extra-splenic tumors, including histiocytic sarcoma, anaplastic sarcoma, mammary carcinoma and lung tumors, were visualized with a heterogeneous enhancement pattern in the post-24 hour scan. Conclusions The long circulating liposomal-iodine contrast agent enabled prolonged visualization of small

  4. Iodinated NanoClusters as an inhaled CT contrast agent for lung visualization

    PubMed Central

    Aillon, Kristin L.; El-Gendy, Nashwa; Norenberg, Jeffery P.; McDonald, Jacob; Dennis, Connor; Berkland, Cory

    2014-01-01

    Improvements to contrast media formulations may be an effective way to increase the accuracy and effectiveness of thoracic computed tomography (CT) imaging in disease evaluation. To achieve contrast enhancement in the lungs, a relatively large localized concentration of contrast media must be delivered. Inhalation offers a non-invasive alternative to intrapleural injections for local lung delivery, but effective aerosolization may deter successful imaging strategies. Here, NanoCluster technology was applied to N1177, a diatrizoic acid derivative, to formulate low density nanoparticle agglomerates with aerodynamic diameters ≤ 5 µm. Excipient-free N1177 NanoCluster powders were delivered to rats by insufflation or inhalation and scanned using CT up to 2 h post dose. CT images after inhalation showed a ~120 HU contrast increase in the lungs, which was more than sufficient contrast for thoracic CT imaging. Lung tissue histology demonstrated that N1177 NanoClusters did not damage the lungs. NanoCluster particle engineering technology offers a novel approach to safely and efficiently disseminate high concentrations of contrast agents to the lung periphery. PMID:20575527

  5. Allergy-like reactions to iodinated contrast agents. A critical analysis.

    PubMed

    Idée, Jean-Marc; Pinès, Emmanuelle; Prigent, Philippe; Corot, Claire

    2005-06-01

    Allergy-like reactions may occur following administration of iodinated contrast media (CM), mostly in at-risk patients (patients with history of previous reaction, history of allergy, co-treated with interleukin-2 or beta-blockers, etc.) but remain generally unpredictable. Severe and fatal reactions are very rare events. All categories of CM may induce such reactions, although first generation (high osmolar CM) have been found to induce a higher rate of adverse events than low osmolar CM. However, no differences were found between the two categories of CM with respect to mortality. Delayed reactions can also occur. There are no differences between the various categories of CM except for non-ionic dimers, which are more likely to induce such effect. Numerous clinical studies have evaluated the prophylactic value of drugs (mostly antihistamines and corticosteroids). Results are unclear and highly variable. Any prevention depends upon the mechanism involved. However, the mechanism of CM-induced allergy-like reaction remains disputed. Relatively recent data revived the hypothesis of a type-I hypersensitivity mechanism. Positive skin tests to CM have been reported. However, the affinity of IgE towards CM has been found to be very low in the only study which actually evaluated it. Other pathophysiological mechanisms (involving direct secretory effects on mast cells or basophils, or activation of the complement system associated or not with the plasma contact system) are also much debated. Anaphylaxis and anaphylactoid reactions are, in the end, clinically undistinguishable. PMID:15910651

  6. Dose distributions using kilovoltage x-rays and dose enhancement from iodine contrast agents

    NASA Astrophysics Data System (ADS)

    Mesa, A. V.; Norman, A.; Solberg, T. D.; Demarco, J. J.; Smathers, J. B.

    1999-08-01

    In x-ray phototherapy of brain tumours, the tumour is loaded with iodine and exposed to kilovoltage x-rays. Due to the high photoelectric cross sections of iodine, substantial photoelectric interactions occur. The flux of photoelectrons, characteristic x-rays and Auger electrons produce a localized dose enhancement. A modified computed tomography scanner, CTRx, can be used both for tumour localization and delivery of the dose enhancement therapy. Monte Carlo methods were employed to simulate the treatment of iodinated brain tumours with a CTRx. The calculated results reveal the effect of tumour iodine concentration on dose distribution, the degree of skull bone sparing with the application of multiple arcs, and the homogeneity of tumour dose distribution versus iodine concentration. A comparison with 10 MV stereotactic radiosurgery treatment shows the potential of CTRx treatment relative to conventional treatment modalities.

  7. Size and CT density of iodine-containing ethosomal vesicles obtained by membrane extrusion: potential for use as CT contrast agents.

    PubMed

    Na, Bomin; Choi, Byoung Wook; Kim, Bumsang

    2013-11-01

    Computed tomography (CT) is the primary non-invasive imaging technique used for most patients with suspected liver disease. In order to improve liver-specific imaging properties and prevent toxic effects in patients with compromised renal function, we investigated the encapsulation of iodine within ethosomal vesicles. As a first step in the development of novel contrast agents using ethosomes for CT imaging applications, iodine was entrapped within ethosomes and iodine-containing ethosomes of the desired size were obtained by extrusion using a polycarbonate membrane with a defined pore size. Ethosomes containing iodine showed a relatively high CT density, which decreased when they were extruded, due to the rupture and re-formation of the lipid bilayer of the ethosome. However, when a solution with a high iodine concentration was used as a dispersion media during the extrusion process, the decrease in CT density could be prevented. In addition, ethosomes containing iodine were taken up efficiently by macrophages, which are abundant in the liver, and these ethosomes exhibited no cellular toxicity. These results demonstrate that iodine could be entrapped within ethosomal vesicles, giving the ethosomes a relatively high CT density, and that the extrusion technique used in this study could conveniently and reproducibly produce ethosomal vesicles with a desired size. Therefore, ethosomes containing iodine, as prepared in this study, have potential as contrast agents with applications in CT imaging. PMID:23857905

  8. Borate complexes of x-ray iodinated contrast agents: characterization and sorption studies for their removal from aqueous media.

    PubMed

    Rustighi, Isabella; Donati, Ivan; Ferluga, Matteo; Campa, Cristiana; Pasqua, Adele E; Rossi, Marco; Paoletti, Sergio

    2012-02-29

    Iodinated contrast media (ICM) are persistent and ubiquitous water pollutants. Because of their high water solubility and biochemical stability, their phase-separation and recovery from the aquatic environment is very difficult. Here, borate was chosen as a complexing agent of the two diagnostic aids iomeprol and iopamidol in order to provide them with a negative charge and to fix the resulting adducts on Dowex 1X4 ion exchangers. A systematic characterization study of the complex by means of capillary zone electrophoresis and 11B NMR revealed that iomeprol and iopamidol interact with borate anions in aqueous solutions giving a 1:1 single-charged adduct and that the association constant at 25 °C for both contrast agents is highest at pH 10.5. These findings allowed the proper calibration of experimental parameters for further batch adsorption-desorption trials, where the two ICM were shown to be almost completely removed from the water phase and released from the solid sorbents in mild conditions, enabling the recovery of functional resin. PMID:22245510

  9. SU-E-QI-21: Iodinated Contrast Agent Time Course In Human Brain Metastasis: A Study For Stereotactic Synchrotron Radiotherapy Clinical Trials

    SciTech Connect

    Obeid, L; Esteve, F; Adam, J; Tessier, A; Balosso, J

    2014-06-15

    Purpose: Synchrotron stereotactic radiotherapy (SSRT) is an innovative treatment combining the selective accumulation of heavy elements in tumors with stereotactic irradiations using monochromatic medium energy x-rays from a synchrotron source. Phase I/II clinical trials on brain metastasis are underway using venous infusion of iodinated contrast agents. The radiation dose enhancement depends on the amount of iodine in the tumor and its time course. In the present study, the reproducibility of iodine concentrations between the CT planning scan day (Day 0) and the treatment day (Day 10) was assessed in order to predict dose errors. Methods: For each of days 0 and 10, three patients received a biphasic intravenous injection of iodinated contrast agent (40 ml, 4 ml/s, followed by 160 ml, 0.5 ml/s) in order to ensure stable intra-tumoral amounts of iodine during the treatment. Two volumetric CT scans (before and after iodine injection) and a multi-slice dynamic CT of the brain were performed using conventional radiotherapy CT (Day 0) or quantitative synchrotron radiation CT (Day 10). A 3D rigid registration was processed between images. The absolute and relative differences of absolute iodine concentrations and their corresponding dose errors were evaluated in the GTV and PTV used for treatment planning. Results: The differences in iodine concentrations remained within the standard deviation limits. The 3D absolute differences followed a normal distribution centered at zero mg/ml with a variance (∼1 mg/ml) which is related to the image noise. Conclusion: The results suggest that dose errors depend only on the image noise. This study shows that stable amounts of iodine are achievable in brain metastasis for SSRT treatment in a 10 days interval.

  10. Successful transfemoral aortic Edwards(®) SAPIEN(®) bioprosthesis implantation without using iodinated contrast media in a woman with severe allergy to contrast agent.

    PubMed

    Leroux, Lionel; Dijos, Marina; Dos Santos, Pierre

    2013-12-01

    Severe anaphylactoid reaction after the use of iodinated contrast media are rare but can contraindicate the use of contrast agent. It was the case of a 53-year-old woman suffering from symptomatic severe aortic stenosis, recused for cardiac surgery because of deleterious effects of chest-wall irradiation, with porcelain aorta. We decided to implant a 23-mm Edwards(®) SAPIEN(®) transcatheter aortic valve via a femoral route without using any contrast media. The implantation was successful after surgical approach of the femoral artery, transesophageal echocardiography guiding, and localization of native leaflets and coronary trunk with catheters. Immediate and one month post-interventional follow-up was favorable and echocardiography showed a good functioning of the aortic bioprosthesis. Although conventional angiography is the best way to visualize the good positioning of the valve before deployment, our case suggests that, in special situations, transfemoral implantation of an Edwards(®) SAPIEN(®) aortic bioprosthesis is feasible without any contrast injection. PMID:23197475

  11. Dual-Energy Computed Tomography Imaging of Atherosclerotic Plaques in a Mouse Model Using a Liposomal-Iodine Nanoparticle Contrast Agent

    PubMed Central

    Bhavane, Rohan; Badea, Cristian; Ghaghada, Ketan B.; Clark, Darin; Vela, Deborah; Moturu, Anoosha; Annapragada, Akshaya; Johnson, G. Allan; Willerson, James T.; Annapragada, Ananth

    2013-01-01

    Background The accumulation of macrophages in inflamed atherosclerotic plaques has been long recognized. In an attempt to develop an imaging agent for detection of vulnerable plaques, we evaluated the feasibility of a liposomal-iodine nanoparticle contrast agent for computed tomography (CT) imaging of macrophage-rich atherosclerotic plaques in a mouse model. Methods and Results Liposomal-iodine formulations varying in particle size and polyethylene glycol coating were fabricated, and shown to stably encapsulate the iodine compound. In vitro uptake studies using optical and CT imaging in the RAW264.7 macrophage cell line identified the formulation that promoted maximal uptake. Dual-energy CT imaging using this formulation in Apolipoprotein E deficient (ApoE−/−) mice (n=8) and control C57BL/6 mice (n=6) followed by spectral decomposition of the dual-energy images enabled imaging of the liposomes localized in the plaque. Imaging cytometry confirmed the presence of liposomes in the plaque and their co-localization with a small fraction (~2%) of the macrophages in the plaque. Conclusions The results demonstrate the feasibility of imaging macrophage-rich atherosclerotic plaques using a liposomal-iodine nanoparticle contrast agent and dual-energy CT. PMID:23349231

  12. Double-low protocol for hepatic dynamic CT scan: Effect of low tube voltage and low-dose iodine contrast agent on image quality.

    PubMed

    Zhang, Xiuli; Li, Shaodong; Liu, Wenlou; Huang, Ning; Li, Jingjing; Cheng, Li; Xu, Kai

    2016-06-01

    The radiation-induced carcinogenesis from computed tomography (CT) and iodine contrast agent induced nephropathy has attracted international attention. The reduction of the radiation dose and iodine intake in CT scan is always a direction for researchers to strive. The purpose of this study was to evaluate the feasibility of a "double-low" (i.e., low tube voltage and low-dose iodine contrast agent) scanning protocol for dynamic hepatic CT with the adaptive statistical iterative reconstruction (ASIR) in patients with a body mass index (BMI) of 18.5 to 27.9 kg/m.A total of 128 consecutive patients with a BMI between 18.5 and 27.9 kg/m were randomly assigned into 3 groups according to tube voltage, iodine contrast agent, and reconstruction algorithms. Group A (the "double-low" protocol): 100 kVp tube voltage with 40% ASIR, iodixanol at 270 mg I/mL, group B: 120 kVp tube voltage with filtered back projection (FBP), iodixanol at 270 mg I/ mL, and group C: 120 kVp tube voltage with FBP, ioversol at 350 mg I/ mL.The volume CT dose index (CTDIvol) and effective dose (ED) in group A were lower than those in group B and C (all P < 0.01). The iodine intake in group A was decreased by approximately 26.5% than group C, whereas no statistical difference was observed between group A and B (P > 0.05). There was no significant difference of the CT values between group A and C (P > 0.05), which both showed higher CT values than that in group B (P < 0.001). However, no statistic difference was observed in the contrast-to-noise ratio (CNR), the signal-to-noise ratio (SNR), and image-quality scores among the 3 groups (all P > 0.05). Near-perfect consistency of the evaluation for group A, B, and C (Kenall's W = 0.921, 0.874, and 0.949, respectively) was obtained by the 4 readers with respect to the overall image quality.These results suggested that the "double-low" protocol with ASIR algorithm for multi-phase hepatic CT scan can dramatically decrease

  13. [Complications related to the administration of iodinated contrast media].

    PubMed

    Cappeliez, O; Lemort, M; Dagnelie, J

    1997-12-01

    Improvement brought to iodinated molecules aims to obtain an optimal enhancement effect together with a lower toxicity. However, benign adverse events remain a common risk, and anaphylactoid reactions from the intravascular administration of iodinated contrast media may occur at random and are unpredictable. Although most contrast reactions are mild and self-limited, severe and even life-threatening reactions can occur at any time and for any kind of agent. Physicians must be aware of possible complications related to administration of this kind of agents and must be able to identify patients at risk, to care for prevention and prescribe an appropriate premedication regimen. PMID:9481156

  14. Renal Safety of Iodinated Contrast Media Depending on Their Osmolarity – Current Outlooks

    PubMed Central

    Mruk, Bartosz

    2016-01-01

    Summary Iodinated contrast media (ICM) are commonly administered pharmaceutical agents. Most often they are used intravenously and intraarterially. Although iodinated contrast agents are relatively safe and widely used, adverse events occur and questions remain about their use, safety, and interactions. The most important adverse effects of contrast media include hypersensitivity reactions, thyroid dysfunction, and contrast-induced nephropathy. Radiologists must be aware of the risk factors for reactions to contrast media. Nonionic iodinated contrast agents can be divided into monomeric, low-osmolar, and dimeric, iso-osmolar classes. The osmotic characteristics of contrast media have been a significant focus in many investigations of contrast-induced nephropathy. PMID:27141236

  15. [Suggestions for prevention of adverse reactions after intravasal administration of iodinated contrast media].

    PubMed

    Kuefner, Michael A; Heinrich, Marc; Bautz, Werner; Uder, Michael

    2008-01-01

    Iodinated contrast media are widely used in computed tomography and angiography. Adverse reactions such as contrast-medium induced nephropathy (CIN), anaphylactoid reactions and iodine-induced thyrotoxicosis are associated with intravasal administration of contrast agents. Iodinated contrast agents are generally considered to be safe, but in rare cases they can cause severe life threatening situations. In this review we present an overview about the incidence, pathways, and risk factors of adverse reactions. Simple schemes including hydration protocols for prevention of CIN, medication for prophylaxis of iodine-induced thyrotoxicosis with thyreostatics and anaphylactoid reactions with histamine antagonists and corticosteroids are suggested. PMID:19294866

  16. Gadofullerene MRI contrast agents.

    PubMed

    Bolskar, Robert D

    2008-04-01

    A promising new class of MRI contrast-enhancing agents with high relaxivities is based on gadolinium-containing metallofullerenes, which are also termed gadofullerenes. Detailed study of the water-proton relaxivity properties and intermolecular nanoclustering behavior of gadofullerene derivatives has revealed valuable information about their relaxivity mechanisms and given a deeper understanding of this new class of paramagnetic contrast agent. Here, the latest findings on water-solubilized gadofullerene materials and how these findings relate to their future applications in MRI are reviewed and discussed. PMID:18373426

  17. Contrast agent choice for intravenous coronary angiography

    SciTech Connect

    Zeman, H.D.; Siddons, D.P.

    1989-01-01

    The screening of the general population for coronary artery disease would be practical if a method existed for visualizing the extent of occlusion after an intravenous injection of contrast agent. Measurements performed with monochromatic synchrotron radiation x-rays and an iodine containing contrast agent at the Stanford Synchrotron Radiation Laboratory have shown that such an intravenous angiography procedure would be possible with an adequately intense monochromatic x-ray source. Because of the size and cost of synchrotron radiation facilities it would be desirable to make the most efficient use of the intensity available, while reducing as much as possible the radiation dose experienced by the patient. By choosing contrast agents containing elements with a higher atomic number than iodine, it is possible to both improve the image quality and reduce the patient radiation dose, while using the same synchrotron source. By using Si monochromator crystals with a small mosaic spread, it is possible to increase the x-ray flux available for imaging by over an order of magnitude, without any changes in the storage ring or wiggler magnet. The most critical imaging task for intravenous coronary angiography utilizing synchrotron radiation x-rays is visualizing a coronary artery through the left ventricle or aorta which also contains a contrast agent. Calculations have been made of the signal to noise ratio expected for this imaging task for various contrast agents with atomic numbers between that of iodine and bismuth.

  18. A Review: Radiographic Iodinated Contrast Media-Induced Thyroid Dysfunction

    PubMed Central

    Leung, Angela M.; Braverman, Lewis E.; Brent, Gregory A.; Pearce, Elizabeth N.

    2015-01-01

    Context: Thyroid hormone production is dependent on adequate iodine intake. Excess iodine is generally well-tolerated, but thyroid dysfunction can occur in susceptible individuals after excess iodine exposure. Radiological iodinated contrast media represent an increasingly common source of excess iodine. Objective: This review will discuss the thyroidal response after acute exposure to excess iodine; contrast iodine-induced thyroid dysfunction; risks of iodine-induced thyroid dysfunction in vulnerable populations, such as the fetus, neonate, and patients with impaired renal function; and recommendations for the assessment and treatment of contrast iodine-induced thyroid dysfunction. Methods: Data for this review were identified by searching PubMed, Google Scholar, and references from relevant articles from 1948 to 2014. Conclusions: With the increase in the use of computed tomography scans in the United States, there is increasing risk of contrast-induced thyroid dysfunction. Patients at risk of developing iodine-induced thyroid dysfunction should be closely monitored after receiving iodinated contrast media and should be treated as needed. PMID:25375985

  19. Contrast agent choice for intravenous coronary angiography

    NASA Astrophysics Data System (ADS)

    Zeman, H. D.; Siddons, D. P.

    1990-05-01

    The screening of the general population for coronary artery disease would be practical if a method existed for visualizing the extent of occlusion after an intravenous injection of contrast agent. Measurements performed with monochromatic synchrotron radiation X-rays and an iodine-containing contrast agent at the Stanford Synchrotron Radiation Laboratory have shown that such an intravenous angiography procedure would be possible with an adequately intense monochromatic X-ray source. Because of the size and cost of synchrotron radiation facilities it would be desirable to make the most efficient use of the intensity available, while reducing as much as possible the radiation dose experienced by the patient. By choosing contrast agents containing elements with a higher atomic number than iodine, it is possible to both improve the image quality and reduce the patient radiation dose, while using the same synchrotron radiation source. By using Si monochromator crystals with a small mosaic spread, it is possible to increase the X-ray flux available for imaging by over an order of magnitude, without any changes in the storage ring or wiggler magnet. The most critical imaging task for intravenous coronary angiography utilizing synchrotron radiation X-rays is visualizing a coronary artery through the left ventricle or aorta which also contain contrast agent. Calculations have been made of the signal to noise ratio expected for this imaging task for various contrast agents with atomic numbers between that of iodine and bismuth. The X-ray energy spectrum of the X-17 superconduction wiggler beam line at the National Synchrotron Light Source at Brookhaven National Laboratory has been used for these calculations. Both perfect Si crystals and Si crystals with a small mosaic spread are considered as monochromators. Contrast agents containing Gd or Yb seem to have about the optimal calculated signal to noise ratio. Gd-DTPA is already approved for use as a contrast agent for

  20. Intravascular iodinated contrast media and the anaesthetist.

    PubMed

    Dickinson, M C; Kam, P C A

    2008-06-01

    The use of intravascular iodinated contrast media (ICM) in radiological investigations is common. Increasingly, anaesthetists and intensivists are involved in the care of patients undergoing these investigations. Whilst the use of ICM is generally safe there are important adverse effects that need to be recognised and measures instigated to prevent or treat these effects. In patients at risk of developing adverse reactions it is important to consider alternative modes of imaging so that ICM can be avoided. Strategies for the prevention of ICM nephropathy should be considered in all patients receiving ICM. Currently intravascular volume expansion with 0.9% saline has the strongest evidence base. The use of isotonic sodium bicarbonate combined with N-acetylcysteine appears promising in providing further benefits. Although the use of N-acetylcysteine alone has not been shown to significantly reduce the incidence of ICM nephropathy it is cheap, has few adverse effects and it would seem reasonable to continue its use in conjunction with intravascular volume expansion. The routine use of corticosteroid and antihistamine premedication is not always effective in preventing general adverse reactions. PMID:18477275

  1. Nuclear magnetic resonance contrast agents

    DOEpatents

    Smith, Paul H.; Brainard, James R.; Jarvinen, Gordon D.; Ryan, Robert R.

    1997-01-01

    A family of contrast agents for use in magnetic resonance imaging and a method of enhancing the contrast of magnetic resonance images of an object by incorporating a contrast agent of this invention into the object prior to forming the images or during formation of the images. A contrast agent of this invention is a paramagnetic lanthanide hexaazamacrocyclic molecule, where a basic example has the formula LnC.sub.16 H.sub.14 N.sub.6. Important applications of the invention are in medical diagnosis, treatment, and research, where images of portions of a human body are formed by means of magnetic resonance techniques.

  2. Nuclear magnetic resonance contrast agents

    DOEpatents

    Smith, P.H.; Brainard, J.R.; Jarvinen, G.D.; Ryan, R.R.

    1997-12-30

    A family of contrast agents for use in magnetic resonance imaging and a method of enhancing the contrast of magnetic resonance images of an object by incorporating a contrast agent of this invention into the object prior to forming the images or during formation of the images. A contrast agent of this invention is a paramagnetic lanthanide hexaazamacrocyclic molecule, where a basic example has the formula LnC{sub 16}H{sub 14}N{sub 6}. Important applications of the invention are in medical diagnosis, treatment, and research, where images of portions of a human body are formed by means of magnetic resonance techniques. 10 figs.

  3. The use of iodinated and gadolinium contrast media during pregnancy and lactation.

    PubMed

    Webb, Judith A W; Thomsen, Henrik S; Morcos, Sameh K

    2005-06-01

    The use of iodinated or gadolinium-based contrast media in pregnant or lactating women often causes concerns in the radiology department because of the principle of not exposing a fetus or neonate to any drugs. Because of the uncertainty about the use of contrast media during pregnancy and lactation, the Contrast Media Safety Committee of the European Society of Urogenital Radiology decided to review the literature and draw up guidelines. An extensive literature search was carried out and summarized in a report. Based on the limited information available, simple guidelines have been drawn up. The report and guidelines were discussed at the 11th European Symposium on Urogenital Radiology in Santiago de Compostela, Spain. Mutagenic and teratogenic effects have not been described after administration of gadolinium or iodinated contrast media. Free iodide in radiographic contrast medium given to the mother has the potential to depress fetal/neonatal thyroid function. Neonatal thyroid function should be checked during the 1st week if iodinated contrast media have been given during pregnancy. No effect on the fetus has been seen after gadolinium contrast media. Only tiny amounts of iodinated or gadolinium-based contrast medium given to a lactating mother reach the milk, and only a minute proportion entering the baby's gut is absorbed. The very small potential risk associated with absorption of contrast medium may be considered insufficient to warrant stopping breast-feeding for 24 h following either iodinated or gadolinium contrast agents. PMID:15609057

  4. Reduction of iodinated contrast medium in CT: feasibility study

    NASA Astrophysics Data System (ADS)

    Nasirudin, Radin A.; Mei, Kai; Kopp, Felix K.; Penchev, Petar; Rummeny, Ernst J.; Fiebich, Martin; Noël, Peter B.

    2015-03-01

    In CT, the magnitude of enhancement is proportional to the amount of contrast medium (CM) injected. However, high doses of iodinated CM pose health risks, ranging from mild side effects to serious complications such as contrast-induced nephropathy (CIN). This work presents a method that enables the reduction of CM dosage, without affecting the diagnostic image quality. The technique proposed takes advantage of the additional spectral information provided by photon-counting CT systems. In the first step, we apply a material decomposition technique on the projection data to discriminate iodine from other materials. Then, we estimated the noise of the decomposed image by calculating the Cramér-Rao lower bound of the parameter estimator. Next, we iteratively reconstruct the iodine-only image by using the decomposed image and the estimation of noise as an input into a maximum-likelihood iterative reconstruction algorithm. Finally, we combine the iodine-only image with the original image to enhance the contrast of low iodine concentrations. The resulting reconstructions show a notably improved contrast in the final images. Quantitatively, the combined image has a significantly improved CNR, while the measured concentrations are closer to the actual concentrations of the iodine. The preliminary results from our technique show the possibility of reducing the clinical dosage of iodine, without affecting the diagnostic image quality.

  5. Nanoparticle Contrast Agents for Computed Tomography: A Focus on Micelles

    PubMed Central

    Cormode, David P.; Naha, Pratap C.; Fayad, Zahi A.

    2014-01-01

    Computed tomography (CT) is an X-ray based whole body imaging technique that is widely used in medicine. Clinically approved contrast agents for CT are iodinated small molecules or barium suspensions. Over the past seven years there has been a great increase in the development of nanoparticles as CT contrast agents. Nanoparticles have several advantages over small molecule CT contrast agents, such as long blood-pool residence times, and the potential for cell tracking and targeted imaging applications. Furthermore, there is a need for novel CT contrast agents, due to the growing population of renally impaired patients and patients hypersensitive to iodinated contrast. Micelles and lipoproteins, a micelle-related class of nanoparticle, have notably been adapted as CT contrast agents. In this review we discuss the principles of CT image formation and the generation of CT contrast. We discuss the progress in developing non-targeted, targeted and cell tracking nanoparticle CT contrast agents. We feature agents based on micelles and used in conjunction with spectral CT. The large contrast agent doses needed will necessitate careful toxicology studies prior to clinical translation. However, the field has seen tremendous advances in the past decade and we expect many more advances to come in the next decade. PMID:24470293

  6. Environmentally responsive MRI contrast agents

    PubMed Central

    Davies, Gemma-Louise; Kramberger, Iris; Davis, Jason J.

    2015-01-01

    Biomedical imaging techniques can provide a vast amount of anatomical information, enabling diagnosis and the monitoring of disease and treatment profile. MRI uniquely offers convenient, non-invasive, high resolution tomographic imaging. A considerable amount of effort has been invested, across several decades, in the design of non toxic paramagnetic contrast agents capable of enhancing positive MRI signal contrast. Recently, focus has shifted towards the development of agents capable of specifically reporting on their local biochemical environment, where a switch in image contrast is triggered by a specific stimulus/biochemical variable. Such an ability would not only strengthen diagnosis but also provide unique disease-specific biochemical insight. This feature article focuses on recent progress in the development of MRI contrast switching with molecular, macromolecular and nanoparticle-based agents. PMID:24040650

  7. Polycatechol Nanoparticle MRI Contrast Agents.

    PubMed

    Li, Yiwen; Huang, Yuran; Wang, Zhao; Carniato, Fabio; Xie, Yijun; Patterson, Joseph P; Thompson, Matthew P; Andolina, Christopher M; Ditri, Treffly B; Millstone, Jill E; Figueroa, Joshua S; Rinehart, Jeffrey D; Scadeng, Miriam; Botta, Mauro; Gianneschi, Nathan C

    2016-02-01

    Amphiphilic triblock copolymers containing Fe(III) -catecholate complexes formulated as spherical- or cylindrical-shaped micellar nanoparticles (SMN and CMN, respectively) are described as new T1-weighted agents with high relaxivity, low cytotoxicity, and long-term stability in biological fluids. Relaxivities of both SMN and CMN exceed those of established gadolinium chelates across a wide range of magnetic field strengths. Interestingly, shape-dependent behavior is observed in terms of the particles' interactions with HeLa cells, with CMN exhibiting enhanced uptake and contrast via magnetic resonance imaging (MRI) compared with SMN. These results suggest that control over soft nanoparticle shape will provide an avenue for optimization of particle-based contrast agents as biodiagnostics. The polycatechol nanoparticles are proposed as suitable for preclinical investigations into their viability as gadolinium-free, safe, and effective imaging agents for MRI contrast enhancement. PMID:26681255

  8. Contrast-Medium-Enhanced Digital Mammography: Contrast vs. Iodine Concentration Phantom Calibration

    SciTech Connect

    Rosado-Mendez, I.; Brandan, M. E.; Villasenor, Y.; Benitez-Bribiesca, L.

    2008-08-11

    This work deals with the application of the contrast-medium-enhanced digital subtraction mammography technique in order to calibrate the contrast level in subtracted phantom images as function of iodine concentration to perform dynamic studies of the contrast-medium uptake in the breast. Previously optimized dual-energy temporal subtraction modalities were used (a) to determine radiological parameters for a dynamic clinical study composed of 1 mask+3 post-contrast images limiting the total mean glandular dose to 2.5 mGy, and (b) to perform a contrast vs iodine concentration calibration using a custom-made phantom. Calculated exposure values were applied using a commercial full-field digital mammography unit. Contrast in subtracted phantom images (one mask and one post-CM) is linear as function of iodine concentration, although the sensitivity (contrast per iodine concentration) decreases beyond 8 mg/mL. This calibration seems to apply only to thin and normal thickness breasts.

  9. Does iodinated contrast medium amplify DNA damage during exposure to radiation.

    PubMed

    Riley, Peter

    2015-01-01

    There is a recognized increased risk of cancer following exposure of humans to ionizing radiation; this is felt to be most likely due to damage to DNA strands during exposure. Damage to DNA strands can be demonstrated microscopically following exposure to X-rays, and new evidence is emerging that this effect may be compounded by administration of iodinated contrast agents. PMID:26234959

  10. Contrast agents in diagnostic imaging: Present and future.

    PubMed

    Caschera, Luca; Lazzara, Angelo; Piergallini, Lorenzo; Ricci, Domenico; Tuscano, Bruno; Vanzulli, Angelo

    2016-08-01

    Specific contrast agents have been developed for x ray examinations (mainly CT), sonography and Magnetic Resonance Imaging. Most of them are extracellular agents which create different enhancement on basis of different vascularization or on basis of different interstitial network in tissues, but some can be targeted to a particular cell line (e.g. hepatocyte). Microbubbles can be used as carrier for therapeutic drugs which can be released in specific targets under sonographic guidance, decreasing systemic toxicity and increasing therapeutic effect. Radiologists have to choose a particular contrast agent knowing its physical and chemical properties and the possibility of adverse reactions and balancing them with the clinical benefits of a more accurate diagnosis. As for any drug, contrast agents can cause adverse events, which are more frequent with Iodine based CA, but also with Gd based CA and even with sonographic contrast agents hypersensitivity reaction can occur. PMID:27168225

  11. S-Nitrosylation in Organs of Mice Exposed to Low or High Doses of γ-Rays: The Modulating Effect of Iodine Contrast Agent at a Low Radiation Dose

    PubMed Central

    Nicolas, Fadia; Wu, Changgong; Bukhari, Salwa; de Toledo, Sonia M.; Li, Hong; Shibata, Masayuki; Azzam, Edouard I.

    2015-01-01

    The covalent addition of nitric oxide (NO•) onto cysteine thiols, or S-nitrosylation, modulates the activity of key signaling proteins. The dysregulation of normal S-nitrosylation contributes to degenerative conditions and to cancer. To gain insight into the biochemical changes induced by low-dose ionizing radiation, we determined global S-nitrosylation by the “biotin switch” assay coupled with mass spectrometry analyses in organs of C57BL/6J mice exposed to acute 0.1 Gy of 137Cs γ-rays. The dose of radiation was delivered to the whole body in the presence or absence of iopamidol, an iodinated contrast agent used during radiological examinations. To investigate whether similar or distinct nitrosylation patterns are induced following high-dose irradiation, mice were exposed in parallel to acute 4 Gy of 137Cs γ rays. Analysis of modulated S-nitrosothiols (SNO-proteins) in freshly-harvested organs of animals sacrificed 13 days after irradiation revealed radiation dose- and contrast agent-dependent changes. The major results were as follows: (i) iopamidol alone had significant effects on S-nitrosylation in brain, lung and liver; (ii) relative to the control, exposure to 0.1 Gy without iopamidol resulted in statistically-significant SNO changes in proteins that differ in molecular weight in liver, lung, brain and blood plasma; (iii) iopamidol enhanced the decrease in S-nitrosylation induced by 0.1 Gy in brain; (iv) whereas a decrease in S-nitrosylation occurred at 0.1 Gy for proteins of ~50 kDa in brain and for proteins of ~37 kDa in liver, an increase was detected at 4 Gy in both organs; (v) mass spectrometry analyses of nitrosylated proteins in brain revealed differential modulation of SNO proteins (e.g., sodium/potassium-transporting ATPase subunit beta-1; beta tubulins; ADP-ribosylation factor 5) by low- and high-dose irradiation; and (vi) ingenuity pathway analysis identified major signaling networks to be modulated, in particular the neuronal nitric oxide

  12. [Adverse reactions to iodinated contrast media: how to prevent them?].

    PubMed

    Berner, Jeanne; Poletti, Pierre-Alexandre; Becker, Christoph D; Nendaz, Mathieu

    2009-10-14

    The incidence of acute iodine contrast media reactions, appearing within the first hour after the procedure, is low but clinically important due to their daily use. Previous adverse reactions to iodinated contrast media, asthma and a history of allergic reaction are the most recognized risk factors, but the identification of patients at risk remains difficult. The efficacy of preventive measures such as corticosteroid and/or antihistaminic administration rests on low-level evidence. Practical recommendations are presented in this article. Rather than relying on the sole administration of a premedication, the importance of other measures must be stressed: assessing the relevance of the indication to the radiologic exam, use of low osmolarity contrast media, and ensuring a proper monitoring of the patient during and after the procedure. PMID:19911686

  13. Iodine vapor staining for atomic number contrast in backscattered electron and X-ray imaging.

    PubMed

    Boyde, Alan; Mccorkell, Fergus A; Taylor, Graham K; Bomphrey, Richard J; Doube, Michael

    2014-12-01

    Iodine imparts strong contrast to objects imaged with electrons and X-rays due to its high atomic number (53), and is widely used in liquid form as a microscopic stain and clinical contrast agent. We have developed a simple technique which exploits elemental iodine's sublimation-deposition state-change equilibrium to vapor stain specimens with iodine gas. Specimens are enclosed in a gas-tight container along with a small mass of solid I2 . The bottle is left at ambient laboratory conditions while staining proceeds until empirically determined completion (typically days to weeks). We demonstrate the utility of iodine vapor staining by applying it to resin-embedded tissue blocks and whole locusts and imaging them with backscattered electron scanning electron microscopy (BSE SEM) or X-ray microtomography (XMT). Contrast is comparable to that achieved with liquid staining but without the consequent tissue shrinkage, stain pooling, or uneven coverage artefacts associated with immersing the specimen in iodine solutions. Unmineralized tissue histology can be read in BSE SEM images with good discrimination between tissue components. Organs within the locust head are readily distinguished in XMT images with particularly useful contrast in the chitin exoskeleton, muscle and nerves. Here, we have used iodine vapor staining for two imaging modalities in frequent use in our laboratories and on the specimen types with which we work. It is likely to be equally convenient for a wide range of specimens, and for other modalities which generate contrast from electron- and photon-sample interactions, such as transmission electron microscopy and light microscopy. PMID:25219801

  14. Iodine Vapor Staining for Atomic Number Contrast in Backscattered Electron and X-ray Imaging

    PubMed Central

    Boyde, Alan; Mccorkell, Fergus A; Taylor, Graham K; Bomphrey, Richard J; Doube, Michael

    2014-01-01

    Iodine imparts strong contrast to objects imaged with electrons and X-rays due to its high atomic number (53), and is widely used in liquid form as a microscopic stain and clinical contrast agent. We have developed a simple technique which exploits elemental iodine's sublimation-deposition state-change equilibrium to vapor stain specimens with iodine gas. Specimens are enclosed in a gas-tight container along with a small mass of solid I2. The bottle is left at ambient laboratory conditions while staining proceeds until empirically determined completion (typically days to weeks). We demonstrate the utility of iodine vapor staining by applying it to resin-embedded tissue blocks and whole locusts and imaging them with backscattered electron scanning electron microscopy (BSE SEM) or X-ray microtomography (XMT). Contrast is comparable to that achieved with liquid staining but without the consequent tissue shrinkage, stain pooling, or uneven coverage artefacts associated with immersing the specimen in iodine solutions. Unmineralized tissue histology can be read in BSE SEM images with good discrimination between tissue components. Organs within the locust head are readily distinguished in XMT images with particularly useful contrast in the chitin exoskeleton, muscle and nerves. Here, we have used iodine vapor staining for two imaging modalities in frequent use in our laboratories and on the specimen types with which we work. It is likely to be equally convenient for a wide range of specimens, and for other modalities which generate contrast from electron- and photon-sample interactions, such as transmission electron microscopy and light microscopy. Microsc. Res. Tech. 77:1044–1051, 2014. © 2014 The Authors. Microscopy Research Technique published by Wiley Periodocals, Inc. PMID:25219801

  15. Renal Artery Stenting Using CO2 Gas Angiography in Combination with Iodinated Contrast Angiography.

    PubMed

    Adachi, Yuya; Endo, Akihiro; Nakashima, Ryuma; Sugamori, Takashi; Takahashi, Nobuyuki; Kinoshita, Yoshihisa; Tanabe, Kazuaki

    2016-01-01

    A 76-year-old woman was hospitalized repeatedly due to unexplained heart failure. On admission, she had hypertensive acute heart failure. Her symptoms disappeared promptly after the initial treatment; however, her systolic blood pressure remained at over 160 mmHg despite her taking three antihypertensive drugs. Closer examination revealed hemodynamically significant right renal artery stenosis and a lack of left kidney function. We performed percutaneous transluminal renal angioplasty using CO2 angiography in combination with iodinated contrast agents. The patient's renal function and blood pressure improved, however, CO2 gas-induced mild ischemic colitis occurred. We discuss the possibility of the use of combined iodinated contrast angiography and CO2 angiography to avoid contrast-induced nephropathy and the complications peculiar to CO2 angiography. PMID:27580543

  16. Optimal exposure techniques for iodinated contrast enhanced breast CT

    NASA Astrophysics Data System (ADS)

    Glick, Stephen J.; Makeev, Andrey

    2016-03-01

    Screening for breast cancer using mammography has been very successful in the effort to reduce breast cancer mortality, and its use has largely resulted in the 30% reduction in breast cancer mortality observed since 1990 [1]. However, diagnostic mammography remains an area of breast imaging that is in great need for improvement. One imaging modality proposed for improving the accuracy of diagnostic workup is iodinated contrast-enhanced breast CT [2]. In this study, a mathematical framework is used to evaluate optimal exposure techniques for contrast-enhanced breast CT. The ideal observer signal-to-noise ratio (i.e., d') figure-of-merit is used to provide a task performance based assessment of optimal acquisition parameters under the assumptions of a linear, shift-invariant imaging system. A parallel-cascade model was used to estimate signal and noise propagation through the detector, and a realistic lesion model with iodine uptake was embedded into a structured breast background. Ideal observer performance was investigated across kVp settings, filter materials, and filter thickness. Results indicated many kVp spectra/filter combinations can improve performance over currently used x-ray spectra.

  17. "Basic MR Relaxation Mechanisms & Contrast Agent Design"

    PubMed Central

    De León-Rodríguez, Luis M.; Martins, André F.; Pinho, Marco; Rofsky, Neil; Sherry, A. Dean

    2015-01-01

    The diagnostic capabilities of magnetic resonance imaging (MRI) have undergone continuous and substantial evolution by virtue of hardware and software innovations and the development and implementation of exogenous contrast media. Thirty years since the first MRI contrast agent was approved for clinical use, a reliance on MR contrast media persists largely to improve image quality with higher contrast resolution and to provide additional functional characterization of normal and abnormal tissues. Further development of MR contrast media is an important component in the quest for continued augmentation of diagnostic capabilities. In this review we will detail the many important considerations when pursuing the design and use of MR contrast media. We will offer a perspective on the importance of chemical stability, particularly kinetic stability, and how this influences one's thinking about the safety of metal-ligand based contrast agents. We will discuss the mechanisms involved in magnetic resonance relaxation in the context of probe design strategies. A brief description of currently available contrast agents will be accompanied by an in-depth discussion that highlights promising MRI contrast agents in development for future clinical and research applications. Our intention is to give a diverse audience an improved understanding of the factors involved in developing new types of safe and highly efficient MR contrast agents and, at the same time, provide an appreciation of the insights into physiology and disease that newer types of responsive agents can provide. PMID:25975847

  18. Iodinated Contrast Does Not Alter Clotting Dynamics in Acute Ischemic Stroke as Measured by Thromboelastography

    PubMed Central

    McDonald, Mark M; Archeval-Lao, Joancy M; Cai, Chunyan; Peng, Hui; Sangha, Navdeep; Parker, Stephanie A; Wetzel, Jeremy; Riney, Stephen A; Cherches, Matt F; Guthrie, Greer J; Roper, Tiffany C; Kawano-Castillo, Jorge F; Pandurengan, Renga; Rahbar, Mohammad H; Grotta, James C

    2014-01-01

    Background and Purpose Iodinated contrast agents used for computed tomography angiography (CTA) may alter fibrin fiber characteristics and decrease fibrinolysis by tissue plasminogen activator (tPA). Thromboelastography (TEG™) measures the dynamics of coagulation and correlates with thrombolysis in acute ischemic stroke (AIS) patients. We hypothesized that receiving CTA prior to tPA will not impair thrombolysis as measured by TEG™. Methods AIS patients receiving 0.9 mg/kg tPA within 4.5 hours of symptom onset were prospectively enrolled. For CTA, 350 mg/dL of iohexol or 320 mg/dL of iodixanol at a dose of 2.2 ml/kg was administered. TEG™ was measured prior to tPA and 10-minutes after tPA bolus. CTA timing was left to the discretion of the treating physician. Results Of 136 AIS patients who received tPA, 47 had CTA prior to tPA bolus, and 42 had either CTA following tPA and post-tPA TEG™ draw or no CTA (non-contrast group). The median change in clot lysis (LY30) following tPA was 95.3% in the contrast group vs. 95.0% in the non-contrast group (p = 0.74). Thus, tPA-induced thrombolysis did not differ between contrast and non-contrast groups. Additionally, there was no effect of contrast on any pre-tPA TEG™ value. Conclusions Our data do not support an effect of iodinated contrast agents on clot formation or tPA activity. PMID:24370757

  19. Intravascular ultrasound-guided central vein angioplasty and stenting without the use of radiographic contrast agents.

    PubMed

    Matthews, Ray; Thomas, Joseph

    2008-05-01

    Patients with contraindications to iodinated radiographic contrast agents present a significant challenge during endovascular intervention. A 46-year-old man with end-stage renal disease and a normally functioning left upper extremity arteriovenous fistula presented with severe left arm edema. The patient's history included repeated severe anaphylactoid reactions with severe respiratory distress upon exposure to iodinated contrast. In an attempt to avoid the use of iodinated contrast, angioplasty and stent placement of a severe central venous stenosis were performed using only fluoroscopy and intravascular sonography. In patients unable to receive iodinated contrast secondary to anaphylactoid reactions, intravascular sonography can be used to guide angioplasty and stenting of central venous stenosis. PMID:18286503

  20. Contrast medium usage reduction in abdominal computed tomography by using high-iodinated concentration contrast medium

    NASA Astrophysics Data System (ADS)

    Suwannasri, A.; Kaewlai, R.; Asavaphatiboon, S.

    2016-03-01

    This study was to determine if administration of a low volume high-concentration iodinated contrast medium can preserve image quality in comparison with regular-concentration intravenous contrast medium in patient undergoing contrast-enhancement abdominal computed tomography (CT). Eighty-four patients were randomly divided into 3 groups of similar iodine delivery rate; A: 1.2 cc/kg of iomeprol-400, B: 1.0 cc/kg of iomeprol-400 and C: 1.5 cc/kg of ioversol-350. Contrast enhancement of the liver parenchyma, pancreas and aorta was quantitatively measured in Hounsfield units and qualitative assessed by a radiologist. T-test was used to evaluate contrast enhancement, and Chi-square test was used to evaluate qualitative image assessment, at significance level of 0.05 with 95% confidence intervals. There were no statistically significant differences in contrast enhancement of liver parenchyma and pancreas between group A and group C in both quantitative and qualitative analyses. Group C showed superior vascular enhancement to group A and B on quantitative analysis.

  1. Development and production of a prototype iodine contrast phantom for CEDEM

    NASA Astrophysics Data System (ADS)

    Leithner, Robert; Knogler, Thomas; Homolka, Peter

    2013-02-01

    Phantoms containing iodine details with clinically relevant iodine concentrations are required to systematically study dose requirements, for quality assurance and optimizing exposure parameters and protocols for contrast enhanced dual energy mammography (CEDEM) applications. Most such phantoms use liquid iodine solutions, challenging the user with air inclusions, evaporation or the necessity for changing the iodine concentration through refilling. A prototype phantom with an array of sintered solid iodine-containing platelets with iodine area weights of 0, 0.25, 0.5, 1, 1.5 and 2 mg cm-2 is described. Disks containing various iodine concentrations were produced using polymer sintering of Iopamidol embedded into a polystyrene/graphite matrix. Iopamidol-containing platelets with a diameter of 0.5 cm and thickness of 550 µm forming an array with gradually increasing iodine area weight, were embedded in PMMA to allow statistical analysis of contrast and contrast-to-noise ratio (CNR). The homogeneity of the plates was tested and images of the phantom were acquired to assess the iodine area density progression and to evaluate phantom accuracy. The phantom was imaged on a mammography system applying low and high energy spectra as used for CEDEM. The disks show good homogeneity. Uncertainties in absolute iodine area weight were estimated ±5%. The iodine CNR showed a linear correlation with R2 > 0.99. Polymer powder sintering works well for producing stable iodine contrast phantoms without the necessity to handle liquid iodine solutions. Thus, it is a promising approach to construct phantoms not only for CEDEM but also angiography or other contrast enhanced methods with iodine details for quality control or research purposes and optimization.

  2. Small-animal microangiography using phase-contrast X-ray imaging and gas as contrast agent

    NASA Astrophysics Data System (ADS)

    Lundström, Ulf; Larsson, Daniel H.; Westermark, Ulrica K.; Burvall, Anna; Hertz, Hans M.

    2014-03-01

    We use propagation-based phase-contrast X-ray imaging with gas as contrast agent to visualize the microvasculature in small animals like mice and rats. The radiation dose required for absorption X-ray imaging is proportional to the minus fourth power of the structure size to be detected. This makes small vessels impossible to image at reasonable radiation doses using the absorption of conventional iodinated contrast agents. Propagation-based phase contrast gives enhanced contrast for high spatial frequencies by moving the detector away from the sample to let phase variations in the transmitted X-rays develop into intensity variations at the detector. Blood vessels are normally difficult to observe in phase contrast even with iodinated contrast agents as the density difference between blood and most tissues is relatively small. By injecting gas into the blood stream this density difference can be greatly enhanced giving strong phase contrast. One possible gas to use is carbon dioxide, which is a clinically accepted X-ray contrast agent. The gas is injected into the blood stream of patients to temporarily displace the blood in a region and thereby reduce the X-ray absorption in the blood vessels. We have shown that this method can be used to image blood vessels down to 8 μm in diameter in mouse ears. The low dose requirements of this method indicate a potential for live small-animal imaging and longitudinal studies of angiogenesis.

  3. Contrast-induced acute kidney injury following iodine opacification other than by intravascular injection

    PubMed Central

    Perrin, Tilman; Hemett, Ould Maouloud; Menth, Markus; Descombes, Eric

    2012-01-01

    Contrast-induced acute kidney injury (CI-AKI) classically occurs following the intravascular administration of iodinated contrast medium (CM). However, some cases of iodine-induced nephrotoxicity have been reported in patients who did not receive intravascular CM, as a consequence of iodine absorption through mucosae, burned skin or interstitial tissues. Recently, we observed the first case of CI-AKI occurring after an enteroclysis without any direct intravascular injection of CM. Here, we report this case, and review other clinical situations in which renal toxicity has been reported following the non-intravascular use of iodinated compounds. PMID:24175084

  4. Anaphylactoid and anaphylactic reactions to iodinated contrast material.

    PubMed

    Laroche, D; Namour, F; Lefrançois, C; Aimone-Gastin, I; Romano, A; Sainte-Laudy, J; Laxenaire, M C; Guéant, J L

    1999-01-01

    Some adverse reactions to iodinated contrast material (ICM) are considered allergy-like, with cutaneous, cardiovascular, respiratory, and digestive symptoms. Allergy-like reactions are usually unpredictable. Reactions are more frequent with ionic than with nonionic material, but the frequency of deaths is almost identical. In a recent study, 20 severe unexpected reactions to ICM, including 10 life-threatening reactions and one death, were investigated by measuring mediators in blood, within the first minutes or hours of reaction. The responsible ICMs were mostly ionic materials. Histamine and tryptase release correlated with the severity of the reaction. Specific IgE against the responsible ICM was significantly higher in reactors than in controls. A few patients had positive skin tests to the administered ICM, suggesting type-I allergic reaction. Only 2.4% and 3.1% of the cases yielded a positive IgE-RIA, in a second retrospective study which included 165 patients recruited during a 4-year period. In conclusion, IgE-mediated anaphylaxis is rare, but it may be one of the possible mechanisms of severe adverse reactions to ICM. PMID:10735643

  5. Carbon dioxide as a substitute for iodine contrast in arteriography during embolectomy

    PubMed Central

    Wolosker, Nelson; Teivelis, Marcelo Passos; Mendes, Cynthia de Almeida; Nishinari, Kenji; Ribeiro, Mariângela de Freitas; Kuzniec, Sergio

    2015-01-01

    Acute limb ischemia can be potentially harmful to the limb and life threatening. Renal failure is a possible outcome associated with release of products of ischemic limb reperfusion. Some authors reported the benefit of performing angiography after embolectomy, even though iodine contrast is also nephrotoxic. We report a case of embolectomy on a patient with renal insufficiency in whom carbon dioxide was used as a substitute for iodine contrast. PMID:26061074

  6. Multifunctional nanoparticles as coupled contrast agents

    PubMed Central

    Jin, Yongdong; Jia, Congxian; Huang, Sheng-Wen; O’Donnell, Matthew; Gao, Xiaohu

    2011-01-01

    Engineering compact imaging probes with highly integrated modalities is a key focus in bionanotechnology and will have profound impact on molecular diagnostics, imaging, and therapeutics. However, combining multiple components on a nanometer scale to create new imaging modalities unavailable from individual components has proven challenging. Here, we demonstrate iron oxide and gold coupled core-shell nanoparticles with well defined structural characteristics (e.g., size, shell thickness, and core-shell separation) and physical properties (e.g., electronic, magnetic, optical, thermal, and acoustic). The resulting multifunctional nanoprobes not only offer contrast for electron microscopy, magnetic resonance imaging, and scattering-based imaging, but more importantly, enable a new imaging mode, magnetomotive photoacoustic (mmPA) imaging, with remarkable contrast enhancement compared to PA images using conventional nanoparticle contrast agents. PMID:20975706

  7. Micro-radiography of biological samples with medical contrast agents

    NASA Astrophysics Data System (ADS)

    Dammer, J.; Weyda, F.; Benes, J.; Sopko, V.; Gelbic, I.

    2013-12-01

    Micro-radiography is an imaging technique that uses X-rays to study the internal structures of objects. This fast and easy imaging tool is based on differential X-ray attenuation by various tissues and structures within biological samples. The experimental setup described is based on the semiconductor pixel X-ray detector Medipix2 and X-ray micro-focus tube. Our micro-radiographic system has been recently used not only for the examination of internal structures of various arthropods and other biological objects but also for tracing some processes in selected model species (we used living larvae of mosquito Culex quinquefasciatus). Low concentrations of iodine, lanthanum or gold particles were used as a tracer (contrast agent). Such contrast agents increase the absorption of X-rays and allow a better visibility of internal structures of model organisms (especially the various cavities, pores, etc.). In addition, the movement of tracers in selected timing experiments demonstrates some physiological functions of digestive and excretory system.

  8. Optical imaging with dynamic contrast agents.

    PubMed

    Wei, Qingshan; Wei, Alexander

    2011-01-24

    Biological imaging applications often employ molecular probes or nanoparticles for enhanced contrast. However, resolution and detection are still often limited by the intrinsic heterogeneity of the sample, which can produce high levels of background that obscure the signals of interest. Herein, we describe approaches to overcome this obstacle based on the concept of dynamic contrast: a strategy for elucidating signals by the suppression or removal of background noise. Dynamic contrast mechanisms can greatly reduce the loading requirement of contrast agents, and may be especially useful for single-probe imaging. Dynamic contrast modalities are also platform-independent, and can enhance the performance of sophisticated biomedical imaging systems or simple optical microscopes alike. Dynamic contrast is performed in two stages: 1) a signal modulation scheme to introduce time-dependent changes in amplitude or phase, and 2) a demodulation step for signal recovery. Optical signals can be coupled with magnetic nanoparticles, photoswitchable probes, or plasmon-resonant nanostructures for modulation by magnetomotive, photonic, or photothermal mechanisms, respectively. With respect to image demodulation, many of the strategies developed for signal processing in electronics and communication technologies can also be applied toward the editing of digital images. The image-processing step can be as simple as differential imaging, or may involve multiple reference points for deconvolution by using cross-correlation algorithms. Periodic signals are particularly amenable to image demodulation strategies based on Fourier transform; the contrast of the demodulated signal increases with acquisition time, and modulation frequencies in the kHz range are possible. Dynamic contrast is an emerging topic with considerable room for development, both with respect to molecular or nanoscale probes for signal modulation, and also to methods for more efficient image processing and editing. PMID

  9. Optimal Contrast Agent Staining of Ligaments and Tendons for X-Ray Computed Tomography.

    PubMed

    Balint, Richard; Lowe, Tristan; Shearer, Tom

    2016-01-01

    X-ray computed tomography has become an important tool for studying the microstructures of biological soft tissues, such as ligaments and tendons. Due to the low X-ray attenuation of such tissues, chemical contrast agents are often necessary to enhance contrast during scanning. In this article, the effects of using three different contrast agents-iodine potassium iodide solution, phosphotungstic acid and phosphomolybdic acid-are evaluated and compared. Porcine anterior cruciate ligaments, patellar tendons, medial collateral ligaments and lateral collateral ligaments were used as the basis of the study. Three samples of each of the four ligament/tendon types were each assigned a different contrast agent (giving a total of twelve samples), and the progression of that agent through the tissue was monitored by performing a scan every day for a total period of five days (giving a total of sixty scans). Since the samples were unstained on day one, they had been stained for a total of four days by the time of the final scans. The relative contrast enhancement and tissue deformation were measured. It was observed that the iodine potassium iodide solution penetrated the samples fastest and caused the least sample shrinkage on average (although significant deformation was observed by the time of the final scans), whereas the phosphomolybdic acid caused the greatest sample shrinkage. Equations describing the observed behaviour of the contrast agents, which can be used to predict optimal staining times for ligament and tendon X-ray computed tomography, are presented. PMID:27078030

  10. Iodine-125 metaraminol: A new platelet specific labeling agent

    SciTech Connect

    Ohmomo, Y.; Yokoyama, A.; Kawaii, K.; Horiuchi, K.; Saji, H.; Torizuka, K.

    1984-01-01

    In the search for a platelet specific labeling agent, Metaraminol (MA), which is a sympatomimetic amine used for the treatment of hypotension, cardiogenic shock and well recognized as a drug actively incorporated and accumulated in platelet, attracted the authors' attention. Using the classical chloramine-T iodination method, a high labeling efficiency near 98%, reaching a specific activity up to about 1000 Ci/mmole was obtained. Upon the harvest of platelet, only as platelet rich plasma (PRP), the labeling with this radiopharmaceutical was easily performed by incubation at 37/sup 0/C for 10 min. Labeling efficiency as high as 63.0 +- 3.1% at 24 x 10/sup 8/ cells/ml was obtained. In in-vitro studies, the unaltered state of I-125 MA labeled platelet, with their cellular functions fully retained was demonstrated. Pharmacological study indicated a specific incorporation of I-125 MA by active transport system similar to that of 5-HT, along with passive diffusion. Then the in-vivo study carried out in rabbits with induced thrombi on the femoral artery, showed rather rapid disappearance of the I-125 MA labeled autologous platelet radioactivity, from circulating blood reaching as high thrombus-to-blood activity ratio as 19.8+-4.3 within 30 min post-administration. This new platelet labeling agent, I-125 MA, has many advantages over the use of IN-111 oxine and holds considerable promise for thrombus imaging with single photon emission CT upon the availability of I-123 MA.

  11. Dual energy iodine contrast CT with monochromatic x-rays

    SciTech Connect

    Dilmanian, F.A.; Wu, X.Y.; Kress, J.

    1995-12-31

    Computed tomography (CT) with monochromatic x-ray beams was used to image phantoms and a live rabbit using the preclinical Multiple Energy Computed Tomography (MECT) system at the National Synchrotron Light Source. MECT has a horizontal fan beam with a subject apparatus rotating about a vertical axis. Images were obtained at 43 keV for single-energy studies, and at energies immediately below and above the 33.17 keV iodine K-edge for dual-energy subtraction CT. Two CdWO{sub 4}-photodiode array detectors were used. The high-resolution detector (0.5 mm pitch, uncollimated) provided 14 line pair/cm in-plane spatial resolution, with lower image noise than conventional CT. Images with the low-resolution detector (1.844-mm pitch, collimated to 0.922 mm detector elements) had a sensitivity for iodine of {approx} 60 {micro}g/cc in 11-mm channels inside a 135 mm-diameter acrylic cylindrical phantom for a slice height of 2.5 mm and a surface does of {approx} 4 cGy. The image noise was {approx} 1 Hounsfield Unit (HU); it was {approx} 3 HU for the same phantom imaged with conventional CT at approximately the same dose, slice height, and spatial resolution ({approx} 7 lp/cm). These results show the potential advantage of MECT, despite present technical limitations.

  12. Nanoparticle contrast agents for optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Gabriele, Michelle Lynn

    Optical coherence tomography (OCT) provides real-time, objective, in-vivo, optical cross-sectional representations of the retina and optic nerve. Recent innovations in image acquisition, including the incorporation of Fourier/spectral-domain detection, have improved imaging speed, sensitivity and resolution. Still, there remain specific structures within ocular OCT images, such as retinal ganglion cells (RGCs), which are of clinical interest but consistently have low contrast. This makes it difficult to differentiate between surrounding layers and structures. The objectives of this project were: (1) To establish a reliable method for OCT imaging of the healthy and diseased mouse eye in order to provide a platform for testing the utility of OCT contrast agents for ocular imaging, (2) To develop antibody-conjugated gold nanoparticles suitable for targeting specific structures and enhancing OCT image contrast in the mouse eye, and (3) To examine the localized contrast-enhancing ability and biocompatibility of gold nanoparticle contrast agents in-vivo. Our organizing hypotheses were that nanoparticles could improve contrast by modulating the intensity of backscattered light detected by OCT and that they could be directed to ocular structures of interest using antibodies specific to cellular markers. A reproducible method for imaging the mouse retina and quantifying retinal thickness was developed and this technique was then applied to a mouse model for retinal ganglion cell loss, optic nerve crush. Gold nanorods were designed specifically to augment the backscattering OCT signal at the same wavelengths of light used in current ophthalmic OCT imaging schemes (resonant wavelength lambda = 840 nm). Anti-CD90.1 (Thy1.1) antibodies were conjugated to the gold nanorods and a protocol for characterization of the success of antibody conjugation was developed. Upon injection, the gold nanorods were found to remain in the vitreous post-injection, with many consumed by an early

  13. Photoacoustic cell for ultrasound contrast agent characterization.

    PubMed

    Alippi, A; Bettucci, A; Biagioni, A; D'Orazio, A; Germano, M; Passeri, D

    2010-10-01

    Photoacoustics has emerged as a tool for the study of liquid gel suspension behavior and has been recently employed in a number of new biomedical applications. In this paper, a photoacoustic sensor is presented which was designed and realized for analyzing photothermal signals from solutions filled with microbubbles, commonly used as ultrasound contrast agents in echographic imaging techniques. It is a closed cell device, where photothermal volume variation of an aqueous solution produces the periodic deflection of a thin membrane closing the cell at the end of a short pipe. The cell then acts as a Helmholtz resonator, where the displacement of the membrane is measured through a laser probe interferometer, whereas photoacoustic signal is generated by a laser chopped light beam impinging onto the solution through a glass window. Particularly, the microbubble shell has been modeled through an effective surface tension parameter, which has been then evaluated from experimental data through the shift of the resonance frequencies of the photoacoustic sensor. This shift of the resonance frequencies of the photoacoustic sensor caused by microbubble solutions is high enough for making such a cell a reliable tool for testing ultrasound contrast agent, particularly for bubble shell characterization. PMID:21034110

  14. Photoacoustic cell for ultrasound contrast agent characterization

    NASA Astrophysics Data System (ADS)

    Alippi, A.; Bettucci, A.; Biagioni, A.; D'Orazio, A.; Germano, M.; Passeri, D.

    2010-10-01

    Photoacoustics has emerged as a tool for the study of liquid gel suspension behavior and has been recently employed in a number of new biomedical applications. In this paper, a photoacoustic sensor is presented which was designed and realized for analyzing photothermal signals from solutions filled with microbubbles, commonly used as ultrasound contrast agents in echographic imaging techniques. It is a closed cell device, where photothermal volume variation of an aqueous solution produces the periodic deflection of a thin membrane closing the cell at the end of a short pipe. The cell then acts as a Helmholtz resonator, where the displacement of the membrane is measured through a laser probe interferometer, whereas photoacoustic signal is generated by a laser chopped light beam impinging onto the solution through a glass window. Particularly, the microbubble shell has been modeled through an effective surface tension parameter, which has been then evaluated from experimental data through the shift of the resonance frequencies of the photoacoustic sensor. This shift of the resonance frequencies of the photoacoustic sensor caused by microbubble solutions is high enough for making such a cell a reliable tool for testing ultrasound contrast agent, particularly for bubble shell characterization.

  15. Contrast Agents for Quantitative MicroCT of Lung Tumors in Mice

    PubMed Central

    Lalwani, Kush; Giddabasappa, Anand; Li, Danan; Olson, Peter; Simmons, Brett; Shojaei, Farbod; Arsdale, Todd Van; Christensen, James; Jackson-Fisher, Amy; Wong, Anthony; Lappin, Patrick B; Eswaraka, Jeetendra

    2013-01-01

    The identification and quantitative evaluation of lung tumors in mouse models is challenging and an unmet need in preclinical arena. In this study, we developed a noninvasive contrast-enhanced microCT (μCT) method to longitudinally evaluate and quantitate lung tumors in mice. Commercially available μCT contrast agents were compared to determine the optimal agent for visualization of thoracic blood vessels and lung tumors in naïve mice and in non-small-cell lung cancer models. Compared with the saline control, iopamidol and iodinated lipid agents provided only marginal increases in contrast resolution. The inorganic nanoparticulate agent provided the best contrast and visualization of thoracic vascular structures; the density contrast was highest at 15 min after injection and was stable for more than 4 h. Differential contrast of the tumors, vascular structures, and thoracic air space by the nanoparticulate agent enabled identification of tumor margins and accurate quantification. μCT data correlated closely with traditional histologic measurements (Pearson correlation coefficient, 0.995). Treatment of ELM4–ALK mice with crizotinib yielded 65% reduction in tumor size and thus demonstrated the utility of quantitative μCT in longitudinal preclinical trials. Overall and among the 3 agents we tested, the inorganic nanoparticulate product was the best commercially available contrast agent for visualization of thoracic blood vessels and lung tumors. Contrast-enhanced μCT imaging is an excellent noninvasive method for longitudinal evaluation during preclinical lung tumor studies. PMID:24326223

  16. MMP-14 Triggered Fluorescence Contrast Agent.

    PubMed

    Nguyen, Mai-Dung; Kang, Kyung A

    2016-01-01

    Matrix metalloproteinase-14 (MMP-14) is involved in cancer invasion, metastasis, and angiogenesis. Therefore, it is considered to be a biomarker for aggressive cancer types, including some of the triple-negative breast cancer. Accurate (i.e., specific) and sensitive detection of MMP-14 can, thus, be important for the early diagnosis of and accurate prognosis for aggressive cancer, including the breast cancer caused by cell line MDA-MB 231. Fluorophore-mediated molecular sensing has been used for detecting biomarkers, for a long time. One way to increase the specificity of the sensing is designing the fluorophore to emit its fluorescence only when it encounters the biomarker of interest. When a fluorophore is placed on the surface of, or very close to a gold nanoparticle (GNP), its fluorescence is quenched. Applying this relationship between the GNP and fluorophore, we have developed a GNP-based, near-infrared fluorescent contrast agent that is highly specific for MMP-14. This agent normally emits only 14-17 % fluorescence of the free fluorophore. When the agent encounters MMP-14, its fluorescence gets fully restored, allowing MMP-14 specific optical signal emission. PMID:27526171

  17. Advances in Magnetic Resonance Imaging Contrast Agents for Biomarker Detection

    PubMed Central

    Sinharay, Sanhita; Pagel, Mark D.

    2016-01-01

    Recent advances in magnetic resonance imaging (MRI) contrast agents have provided new capabilities for biomarker detection through molecular imaging. MRI contrast agents based on the T2 exchange mechanism have more recently expanded the armamentarium of agents for molecular imaging. Compared with T1 and T2* agents, T2 exchange agents have a slower chemical exchange rate, which improves the ability to design these MRI contrast agents with greater specificity for detecting the intended biomarker. MRI contrast agents that are detected through chemical exchange saturation transfer (CEST) have even slower chemical exchange rates. Another emerging class of MRI contrast agents uses hyperpolarized 13C to detect the agent with outstanding sensitivity. These hyperpolarized 13C agents can be used to track metabolism and monitor characteristics of the tissue microenvironment. Together, these various MRI contrast agents provide excellent opportunities to develop molecular imaging for biomarker detection. PMID:27049630

  18. Advances in Magnetic Resonance Imaging Contrast Agents for Biomarker Detection.

    PubMed

    Sinharay, Sanhita; Pagel, Mark D

    2016-06-12

    Recent advances in magnetic resonance imaging (MRI) contrast agents have provided new capabilities for biomarker detection through molecular imaging. MRI contrast agents based on the T2 exchange mechanism have more recently expanded the armamentarium of agents for molecular imaging. Compared with T1 and T2* agents, T2 exchange agents have a slower chemical exchange rate, which improves the ability to design these MRI contrast agents with greater specificity for detecting the intended biomarker. MRI contrast agents that are detected through chemical exchange saturation transfer (CEST) have even slower chemical exchange rates. Another emerging class of MRI contrast agents uses hyperpolarized (13)C to detect the agent with outstanding sensitivity. These hyperpolarized (13)C agents can be used to track metabolism and monitor characteristics of the tissue microenvironment. Together, these various MRI contrast agents provide excellent opportunities to develop molecular imaging for biomarker detection. PMID:27049630

  19. Advances in Magnetic Resonance Imaging Contrast Agents for Biomarker Detection

    NASA Astrophysics Data System (ADS)

    Sinharay, Sanhita; Pagel, Mark D.

    2016-06-01

    Recent advances in magnetic resonance imaging (MRI) contrast agents have provided new capabilities for biomarker detection through molecular imaging. MRI contrast agents based on the T2 exchange mechanism have more recently expanded the armamentarium of agents for molecular imaging. Compared with T1 and T2* agents, T2 exchange agents have a slower chemical exchange rate, which improves the ability to design these MRI contrast agents with greater specificity for detecting the intended biomarker. MRI contrast agents that are detected through chemical exchange saturation transfer (CEST) have even slower chemical exchange rates. Another emerging class of MRI contrast agents uses hyperpolarized 13C to detect the agent with outstanding sensitivity. These hyperpolarized 13C agents can be used to track metabolism and monitor characteristics of the tissue microenvironment. Together, these various MRI contrast agents provide excellent opportunities to develop molecular imaging for biomarker detection.

  20. Iodine

    MedlinePlus

    ... of iodine are POSSIBLY UNSAFE. Adults should avoid prolonged use of doses higher than 1100 mcg per ... enlarged thyroid gland (goiter), or a thyroid tumor: Prolonged use or high doses of iodine might make ...

  1. Iodine

    MedlinePlus

    ... 6 weeks increases the healing rate. Also, applying povidone-iodine in addition to compression seems help heal ... Catheter-related infection. Some evidence suggests that applying povidone-iodine reduces the risk of blood stream infections ...

  2. Iodine

    MedlinePlus

    ... the amount depends on the iodine in the soil where they grew and in any fertilizer that ... babies. People living in regions with iodine-deficient soils who eat mostly local foods. These soils produce ...

  3. Optimal Contrast Agent Staining of Ligaments and Tendons for X-Ray Computed Tomography

    PubMed Central

    Balint, Richard; Lowe, Tristan

    2016-01-01

    X-ray computed tomography has become an important tool for studying the microstructures of biological soft tissues, such as ligaments and tendons. Due to the low X-ray attenuation of such tissues, chemical contrast agents are often necessary to enhance contrast during scanning. In this article, the effects of using three different contrast agents—iodine potassium iodide solution, phosphotungstic acid and phosphomolybdic acid—are evaluated and compared. Porcine anterior cruciate ligaments, patellar tendons, medial collateral ligaments and lateral collateral ligaments were used as the basis of the study. Three samples of each of the four ligament/tendon types were each assigned a different contrast agent (giving a total of twelve samples), and the progression of that agent through the tissue was monitored by performing a scan every day for a total period of five days (giving a total of sixty scans). Since the samples were unstained on day one, they had been stained for a total of four days by the time of the final scans. The relative contrast enhancement and tissue deformation were measured. It was observed that the iodine potassium iodide solution penetrated the samples fastest and caused the least sample shrinkage on average (although significant deformation was observed by the time of the final scans), whereas the phosphomolybdic acid caused the greatest sample shrinkage. Equations describing the observed behaviour of the contrast agents, which can be used to predict optimal staining times for ligament and tendon X-ray computed tomography, are presented. PMID:27078030

  4. Iodine

    USGS Publications Warehouse

    Krukowski, S.T.

    2006-01-01

    In descending order, Chile, Japan and the United States have the largest iodine reserves. Chile produces iodine from iodate minerals while Japan and the United States produce it from sodium iodide solutions found in underground iodide solutions. Iodine is also produced from subterranean brines in Azerbaijan, Russia, Turkmenista, Indonesia and Uzbekistan. In 2005, iodine prices increased sharply to US$19 to US$23 then leveled off at US$23 to US$25.

  5. Breakthrough reactions of iodinated and gadolinium contrast media after oral steroid premedication protocol

    PubMed Central

    2014-01-01

    Background Adverse reactions to iodinated and gadolinium contrast media are an important clinical issue. Although some guidelines have proposed oral steroid premedication protocols to prevent adverse reactions, some patients may have reactions to contrast media in spite of premedication (breakthrough reaction; BTR). The purpose of this study was to assess the frequency, type and severity of BTR when following an oral steroid premedication protocol. Methods All iodinated and gadolinium contrast-enhanced radiologic examinations between August 2011 and February 2013 for which the premedication protocol was applied in our institution were assessed for BTRs. Results The protocol was applied to a total of 252 examinations (153 patients, ages 15–87 years; 63 males, 90 females). Of these, 152 were for prior acute adverse reactions to contrast media, 85 were for a history of bronchial asthma, and 15 were for other reasons. There were 198 contrast enhanced CTs and 54 contrast enhanced MRIs. There were nine BTR (4.5%) for iodinated contrast media, and only one BTR (1.9%) for gadolinium contrast media: eight were mild and one was moderate. No patient who had a mild index reaction (IR) had a severe BTR. Conclusion Incidence of BTRs when following the premedication protocol was low. This study by no means proves the efficacy of premedication, but provides some support for following a premedication protocol to improve safety of contrast-enhanced examinations when prior adverse reactions are mild, or when there is a history of asthma. PMID:25287952

  6. Gene transfection by echo contrast agent microbubbles

    NASA Astrophysics Data System (ADS)

    Tachibana, Katsuro

    2002-11-01

    In vitro and in vivo experiments have demonstrated that various echo contrast agent microbubbles can be intentionally ruptured by diagnostic and therapeutic ultrasound. Violent microstreaming are produced during microbubble collapse. Researchers have hypothesized that these microjets or microstreaming could be applied to promote diffusion of drugs into various tissues and lesions. The most exciting application of this method is probably delivery of genes into cells. As various genes are currently under investigation for the purpose of treating diseases, ultrasound and microbubbles may be used as a modality to promote better outcome for gene therapy. Recent studies have shown that different gases contained within the bubbles greatly influence the degree of gene transfection. Also, the outer layer of the microbubbles can be custom-made for binding to target tissue. Recent advance on this topic will be discussed.

  7. Intraoperative imaging using intravascular contrast agent

    NASA Astrophysics Data System (ADS)

    Watson, Jeffrey R.; Martirosyan, Nikolay; Garland, Summer; Lemole, G. Michael; Romanowski, Marek

    2016-03-01

    Near-infrared (NIR) contrast agents are becoming more frequently studied in medical imaging due to their advantageous characteristics, most notably the ability to capture near-infrared signal across the tissue and the safety of the technique. This produces a need for imaging technology that can be specific for both the NIR dye and medical application. Indocyanine green (ICG) is currently the primary NIR dye used in neurosurgery. Here we report on using the augmented microscope we described previously for image guidance in a rat glioma resection. Luc-C6 cells were implanted in a rat in the left-frontal lobe and grown for 22 days. Surgical resection was performed by a neurosurgeon using augmented microscopy guidance with ICG contrast. Videos and images were acquired to evaluate image quality and resection margins. ICG accumulated in the tumor tissue due to enhanced permeation and retention from the compromised bloodbrain- barrier. The augmented microscope was capable of guiding the rat glioma resection and intraoperatively highlighted tumor tissue regions via ICG fluorescence under normal illumination of the surgical field.

  8. Allergic reactions to iodinated contrast media: premedication considerations for patients at risk.

    PubMed

    Schopp, Jennifer G; Iyer, Ramesh S; Wang, Carolyn L; Petscavage, Jonelle M; Paladin, Angelisa M; Bush, William H; Dighe, Manjiri K

    2013-08-01

    The objectives of this article are to review allergy-type reactions to iodinated contrast media and the protocols utilized to prevent or reduce the occurrence of these adverse reactions in high-risk patients. We will begin by discussing the types or classifications of the adverse reactions to iodinated contrast media. We will then discuss reaction mechanisms, identify the patients at highest risk for adverse reactions, and clarify common misperceptions about the risk. Finally, we will discuss the actions of the medications used to help reduce or prevent allergy-type reactions to iodinated contrast media, the protocols used to help reduce or prevent contrast reactions in high-risk patients, and the potential side effects of these medications. We will also discuss the high-risk patient who has received premedication due to a prior index reaction and discuss the risk of having a subsequent reaction, termed "breakthrough reaction." Identifying patient at high risk for an "allergy-type" reaction to contrast media is an essential task of the radiologist. Prevention of or reduction of the risk of an adverse reaction is critical to patient safety. If an examination can be performed without contrast in a patient at high risk for an allergy-type reaction, it may be appropriate to avoid contrast. However, there are situations where contrast media is necessary, and the radiologist plays a vital role in preventing or mitigating an allergy-type reaction. PMID:23430296

  9. Role of iodinated contrast material in the evaluation of myocardial infarction by computerized transmission tomography.

    PubMed

    Higgins, C B; Siemers, P T; Newell, J D; Schmidt, W

    1980-01-01

    In vivo and in vitro studies have shown that areas of myocardial infarctions can be delineated on CT scans after intravenous administration of iodinated contrast material to dogs with experimental myocardial infarctions. Within the first minute after intravenous administration of contrast material (initial myocardial perfusion phase), the infarct appears an as area of decreased x-ray attenuation (cold spot image). Studies using radiolabeled microspheres indicate that the relative attenuation numbers throughout the myocardium in this phase reflect myocardial perfusion (Hessel et al, 1978). Delayed scans obtained at 5 minutes and later showed a reversal in the attenuation values of normal and infarcted myocardium with the infarct appearing as an area of homogeneous or mottled increase in x-ray density compared to normal myocardium. (Siemers et al, 1978; Carlsson et al, 1977; Higgins et al, 1979). This phenomenon of delayed contrast enhancement of myocardial infarctions ensues as early as 8 hours after coronary occlusion (Higgins et al, 1979) and is present in evolved infarcts as old as 51 days (Newell et al, 1979). Direct measurements of iodine concentration in infarcts, normal myocardium, and organs surrounding the heart were performed in dogs with 48-hour-old myocardial infarctions using fluorescent excitation analysis (Higgins et al, 1978, 1979). These measurements of iodine concentration in tissue samples obtained at 10-180 minutes after intravenous administration of contrast material indicated that the highest iodine concentration in the infarct was at 10 minutes, but the highest ratio of iodine concentration of the infarct to normal myocardium was at 180 minutes. At all time intervals, the concentration of iodine within the infarct was fivefold greater than in the normal myocardium. PMID:7203920

  10. SU-E-I-45: Feasibility for Using Iodine Quantification to Assist Diagnosis in Dual Energy Contrast-Enhanced Digital Mammography

    SciTech Connect

    Hwang, Y; Lin, Y; Tsai, C; Cheung, Y

    2015-06-15

    Purpose: The objective of this study is to develop quantitative calibration between image quality indexes and iodine concentration with dual-energy (DE) contrast-enhanced digital mammography (CEDM) techniques and further serve as the assistance for diagnosis. Methods: Custom-made acrylic phantom with dimensions of 24×30 cm{sup 2} simulated breast thickness from 2 to 6 cm was used in the calibration. The phantom contained matrix of four times four holes of 3 mm deep with a diameter of 15 mm for filling contrast agent with area density ranged from 0.1 to 10 mg/cm{sup 2}. All the image acquisitions were performed on a full-field digital mammography system (Senographe Essential, GE) with dual energy acquisitions. Mean pixel value (MPV), and contrast-to-noise ratio (CNR) were used for evaluating the relationship between image quality indexes and iodine concentration. Iodine map and CNR map could further be constructed with these calibration curves applied pixel by pixel utilized MATLAB software. Minimum iodine concentration could also be calculated with the visibility threshold of CNR=5 according the Rose model. Results: When evaluating the DE subtraction images, MPV increased linearly as the iodine concentration increased with all the phantom thickness surveyed (R{sup 2} between 0.989 and 0.992). Lesions with increased iodine uptake could thus be enhanced in the color-encoded iodine maps, and the mean iodine concentration could be obtained through the ROI measurements. As for investigating CNR performance, linear relationships were also shown between the iodine concentration and CNR (R{sup 2} between 0.983 and 0.990). Minimum iodine area density of 1.45, 1.73, 1.80, 1.73 and 1.72 mg/cm{sup 2} for phantom thickness of 2, 3, 4, 5, 6 cm were calculated based on Rose’s visualization criteria. Conclusion: Quantitative calibration between image quality indexes and iodine concentrations may further serving as the assistance for analyzing contrast enhancement for patient

  11. Dual-energy coronary angiography in pigs using a Gd contrast agent

    NASA Astrophysics Data System (ADS)

    Fiedler, Stefan; Elleaume, Helene; Le Duc, Geraldine; Nemoz, Christian; Brochard, Thierry; Renier, Michel; Bertrand, Bernard; Esteve, Francois; Le Bas, Jean-Francois; Suortti, Pekka; Thomlinson, William C.

    2000-04-01

    The European Synchrotron Radiation Facility Medical Research Beamline is now fully operational. One of the primary programs is the development of dual-energy transvenous coronary angiography for in vivo human research protocols. Previous work at this and other synchrotrons has been entirely devoted to the use of the dual-energy digital subtraction technique at the iodine k-absorption edge at 33.17 keV. The images are recorded in a line scan mode following venous injection of the contrast agent. Considerations of the patient dose, the dilution of the contrast agent in the pulmonary system and the arteries overlying the filled ventricles have limited the image quality. The ESRF facility was designed to allow dual- energy imaging at higher energies, for example at the gadolinium k-absorption edge at 50.24 keV. The advantages have been theoretically known for many years, with the higher energy promising higher image quality with less radiation dose. During the commissioning phase of the ESRF angiography program, the opportunity presented itself to image adult pigs in vivo with Gd contrast agent. This paper presents some initial results of the image quality in the Gd studies in comparison with iodine contrast agent studies, also carried out in adult pigs at the ESRF.

  12. Shellfish allergy and relation to iodinated contrast media: United Kingdom survey

    PubMed Central

    Baig, Mudassar; Farag, Ahmad; Sajid, Jamal; Potluri, Rahul; Irwin, R Bruce; Khalid, Hafiz Mohammed Idrees

    2014-01-01

    AIM: To assess current practice of United Kingdom cardiologists with respect to patients with reported shellfish/iodine allergy, and in particular the use of iodinated contrast for elective coronary angiography. Moreover we have reviewed the current evidence-base and guidelines available in this area. METHODS: A questionnaire survey was send to 500 senior United Kingdom cardiologists (almost 50% cardiologists registered with British Cardiovascular Society) using email and first 100 responses used to analyze practise. We involved cardiologists performing coronary angiograms routinely both at secondary and tertiary centres. Three specific questions relating to allergy were asked: (1) History of shellfish/iodine allergy in pre-angiography assessment; (2) Treatments offered for shellfish/iodine allergy individuals; and (3) Any specific treatment protocol for shellfish/iodine allergy cases. We aimed to establish routine practice in United Kingdom for patients undergoing elective coronary angiography. We also performed comprehensive PubMed search for the available evidence of relationship between shellfish/iodine allergy and contrast media. RESULTS: A total of 100 responses were received, representing 20% of all United Kingdom cardiologists. Ninety-three replies were received from consultant cardiologists, 4 from non-consultant grades and 3 from cardiology specialist nurses. Amongst the respondents, 66% routinely asked about a previous history of shellfish/iodine allergy. Fifty-six percent would pre-treat these patients with steroids and anti-histamines. The other 44% do nothing, or do nonspecific testing based on their personal experience as following: (1) Skin test with 1 mL of subcutaneous contrast before intravenous contrast; (2) Test dose 2 mL contrast before coronary injection; (3) Close observation for shellfish allergy patients; and (4) Minimal evidence that the steroid and anti-histamine regime is effective but it makes us feel better. CONCLUSION: There is no

  13. Successful stent implantation guided by intravascular ultrasound and a Doppler guidewire without contrast injection in a patient with allergy to iodinated contrast media.

    PubMed

    Okura, Hiroyuki; Nezuo, Shintaro; Yoshida, Kiyoshi

    2011-07-01

    Presence of allergy to iodinated contrast may prevent percutaneous coronary intervention (PCI) to be performed. We present a 76-year-old male with a history of allergic reaction to iodinated contrast who successfully underwent intravascular ultrasound (IVUS) and a Doppler guidewire-guided PCI. Stent size was determined based on IVUS. After PCI, stent expansion and a lack of edge dissection or incomplete apposition were confirmed by IVUS and a good antegrade coronary flow was confirmed by a Doppler guidewire. Thus, PCI without contrast injection under IVUS and a Doppler guidewire-guidance may be feasible in selected patients with allergy to iodinated contrast. PMID:21725127

  14. Tumor-specific fluorescent contrast agents

    NASA Astrophysics Data System (ADS)

    Achilefu, Samuel I.; Dorshow, Richard B.; Bugaj, Joseph E.; Rajagopalan, Raghavan

    2000-04-01

    Several dyes are currently used for various biomedical applications due to their biocompatibility and high molar absorptivity. Localization of dyes in tumors may be mediated by several factors such as leaky vasculature and high metabolic activity in proliferating cells. However, these mechanisms of action make it difficult to differentiate inflammation from benign or malignant tumors. In order to enhance their tumor specificity, dyes have been conjugated to biomolecules that target unique factors in various diseased state. However, such large biomolecules can elicit adverse immunogenic reactions in humans, and are often preferentially taken up by the liver. Furthermore, for solid tumors which may rely on diffusion of the biomarkers from the vascular, penetration of large dye conjugates is not favorable. To overcome these problems, we designed and synthesized novel dye-peptide conjugates that are receptor specific. The efficacy of these new fluorescent contrast agents was tested in vivo in well-characterized rat tumor lines. The resulting optical images demonstrate that successful specific tumor targeting was achieved.

  15. A method to evaluate the dose increase in CT with iodinated contrast medium

    SciTech Connect

    Amato, Ernesto; Lizio, Domenico; Settineri, Nicola; Di Pasquale, Andrea; Salamone, Ignazio; Pandolfo, Ignazio

    2010-08-15

    Purpose: The objective of this study is to develop a method to calculate the relative dose increase when a computerized tomography scan (CT) is carried out after administration of iodinated contrast medium, with respect to the same CT scan in absence of contrast medium. Methods: A Monte Carlo simulation in GEANT4 of anthropomorphic neck and abdomen phantoms exposed to a simplified model of CT scanner was set up in order to calculate the increase of dose to thyroid, liver, spleen, kidneys, and pancreas as a function of the quantity of iodine accumulated; a series of experimental measurements of Hounsfield unit (HU) increment for known concentrations of iodinated contrast medium was carried out on a Siemens Sensation 16 CT scanner in order to obtain a relationship between the increment in HU and the relative dose increase in the organs studied. The authors applied such a method to calculate the average dose increase in three patients who underwent standard CT protocols consisting of one native scan in absence of contrast, followed by a contrast-enhanced scan in venous phase. Results: The authors validated their GEANT4 Monte Carlo simulation by comparing the resulting dose increases for iodine solutions in water with the ones presented in literature and with their experimental data obtained through a Roentgen therapy unit. The relative dose increases as a function of the iodine mass fraction accumulated and as a function of the Hounsfield unit increment between the contrast-enhanced scan and the native scan are presented. The data shown for the three patients exhibit an average relative dose increase between 22% for liver and 74% for kidneys; also, spleen (34%), pancreas (28%), and thyroid (48%) show a remarkable average increase. Conclusions: The method developed allows a simple evaluation of the dose increase when iodinated contrast medium is used in CT scans, basing on the increment in Hounsfield units observed on the patients' organs. Since many clinical protocols

  16. Adverse reactions to intravenous iodinated contrast media: a primer for radiologists.

    PubMed

    Namasivayam, Saravanan; Kalra, Mannudeep K; Torres, William E; Small, William C

    2006-07-01

    Adverse reactions to intravenous iodinated contrast media may be classified as general and organ-specific, such as contrast-induced nephrotoxicity. General adverse reactions may be subclassified into acute and delayed types. Acute general adverse reactions can range from transient minor reactions to life-threatening severe reactions. Non-ionic contrast media have lower risk of mild and moderate adverse reactions. However, the risk of fatal reactions is similar for ionic and non-ionic contrast media. Adequate preprocedure evaluation should be performed to identify predisposing risk factors. Prompt recognition and treatment of acute adverse reactions is crucial. Risk of contrast induced nephrotoxicity can be reduced by use of non-ionic contrast media, less volume of contrast, and adequate hydration. The radiologist can play a pivotal role by being aware of predisposing factors, clinical presentation, and management of adverse reactions to contrast media. PMID:16688432

  17. Taxanes as a Risk Factor for Acute Adverse Reactions to Iodinated Contrast Media in Cancer Patients

    PubMed Central

    Farolfi, Alberto; Della Luna, Corradina; Ragazzini, Angela; Carretta, Elisa; Gentili, Nicola; Casadei, Carla; Aquilina, Michele; Barone, Domenico; Minguzzi, Martina; Amadori, Dino; Nanni, Oriana

    2014-01-01

    Background. The impact of cytotoxic agents on the risk of acute allergy-like adverse reactions (ARs) to intravenous iodinated contrast media (ICM) injections is unknown. Methods. We retrospectively reviewed 13,565 computed tomography (CT) scans performed in a consecutive cohort of cancer patients from January 1, 2010 to December 31, 2012. Episodes of acute ICM-related ARs were reported to the pharmacovigilance officer. The following matched comparisons were made: tax code, gender, primary tumor, antineoplastic therapy, and date of last cycle. Concomitant antineoplastic treatment was classified into five groups: platinum, taxane, platinum plus taxane, other, and no treatment group (no therapy had been administered in the previous 24 months). Logistic regression was used to estimate odds ratio (OR) and 95% confidence interval (CI) to evaluate the risk of acute ICM-related ARs. Results. Of 10,472 contrast-enhanced CT scans, 97 (0.93%; 95% CI: 0.74–1.11) ICM-related ARs were reported, 11 of which (0.1%) were severe, including one fatality. The overall incidence was significantly higher in patients aged <65 years (p = .0062) and in the platinum plus taxane and taxane groups (p = .007), whereas no correlation was found with gender, number of previous CT scans, site of disease, or treatment setting. Multivariate analysis confirmed an increased risk for patients aged <65 years (OR: 1.73; 95% CI: 1.14–2.63) and for the taxane group (in comparison with the no treatment group; OR: 2.06; 95% CI: 1.02–4.16). Conclusion. Among cancer patients, concomitant treatment with taxanes and younger age would seem to be risk factors for ICM-related ARs. PMID:25063226

  18. Analysis of iodinated contrast delivered during thermal ablation: is material trapped in the ablation zone?

    NASA Astrophysics Data System (ADS)

    Wu, Po-hung; Brace, Chris L.

    2016-08-01

    Intra-procedural contrast-enhanced CT (CECT) has been proposed to evaluate treatment efficacy of thermal ablation. We hypothesized that contrast material delivered concurrently with thermal ablation may become trapped in the ablation zone, and set out to determine whether such an effect would impact ablation visualization. CECT images were acquired during microwave ablation in normal porcine liver with: (A) normal blood perfusion and no iodinated contrast, (B) normal perfusion and iodinated contrast infusion or (C) no blood perfusion and residual iodinated contrast. Changes in CT attenuation were analyzed from before, during and after ablation to evaluate whether contrast was trapped inside of the ablation zone. Visualization was compared between groups using post-ablation contrast-to-noise ratio (CNR). Attenuation gradients were calculated at the ablation boundary and background to quantitate ablation conspicuity. In Group A, attenuation decreased during ablation due to thermal expansion of tissue water and water vaporization. The ablation zone was difficult to visualize (CNR  =  1.57  ±  0.73, boundary gradient  =  0.7  ±  0.4 HU mm‑1), leading to ablation diameter underestimation compared to gross pathology. Group B ablations saw attenuation increase, suggesting that iodine was trapped inside the ablation zone. However, because the normally perfused liver increased even more, Group B ablations were more visible than Group A (CNR  =  2.04  ±  0.84, boundary gradient  =  6.3  ±  1.1 HU mm‑1) and allowed accurate estimation of the ablation zone dimensions compared to gross pathology. Substantial water vaporization led to substantial attenuation changes in Group C, though the ablation zone boundary was not highly visible (boundary gradient  =  3.9  ±  1.1 HU mm‑1). Our results demonstrate that despite iodinated contrast being trapped in the ablation zone, ablation visibility

  19. Analysis of iodinated contrast delivered during thermal ablation: is material trapped in the ablation zone?

    PubMed

    Wu, Po-Hung; Brace, Chris L

    2016-08-21

    Intra-procedural contrast-enhanced CT (CECT) has been proposed to evaluate treatment efficacy of thermal ablation. We hypothesized that contrast material delivered concurrently with thermal ablation may become trapped in the ablation zone, and set out to determine whether such an effect would impact ablation visualization. CECT images were acquired during microwave ablation in normal porcine liver with: (A) normal blood perfusion and no iodinated contrast, (B) normal perfusion and iodinated contrast infusion or (C) no blood perfusion and residual iodinated contrast. Changes in CT attenuation were analyzed from before, during and after ablation to evaluate whether contrast was trapped inside of the ablation zone. Visualization was compared between groups using post-ablation contrast-to-noise ratio (CNR). Attenuation gradients were calculated at the ablation boundary and background to quantitate ablation conspicuity. In Group A, attenuation decreased during ablation due to thermal expansion of tissue water and water vaporization. The ablation zone was difficult to visualize (CNR  =  1.57  ±  0.73, boundary gradient  =  0.7  ±  0.4 HU mm(-1)), leading to ablation diameter underestimation compared to gross pathology. Group B ablations saw attenuation increase, suggesting that iodine was trapped inside the ablation zone. However, because the normally perfused liver increased even more, Group B ablations were more visible than Group A (CNR  =  2.04  ±  0.84, boundary gradient  =  6.3  ±  1.1 HU mm(-1)) and allowed accurate estimation of the ablation zone dimensions compared to gross pathology. Substantial water vaporization led to substantial attenuation changes in Group C, though the ablation zone boundary was not highly visible (boundary gradient  =  3.9  ±  1.1 HU mm(-1)). Our results demonstrate that despite iodinated contrast being trapped in the ablation zone, ablation visibility

  20. Adverse reactions to iodinated contrast media administered at the time of endoscopic retrograde cholangiopancreatography (ERCP).

    PubMed

    Pan, Jen-Jung; Draganov, Peter V

    2009-03-01

    Adverse reactions after intravascular administration of iodine contrast media are common and prophylactic regiments consisting of the use of steroids and low osmolality contrast media are highly effective in significantly decreasing the adverse reactions rate. The same type of contrast media are also used for opacification of the biliary tree and the pancreatic duct at the time of endoscopic retrograde cholangiopancreatography (ERCP). Systemic absorption of contrast media after ERCP routinely occurs. Although the adverse reaction rate appears to be very low the exact incidence remains unknown due to the retrospective nature of all reports. Despite the lack of formal recommendations, numerous prophylactic regiments are routinely used prior to ERCP in patients with history of prior reaction to intravascular contrast media. Moreover, the use of prophylaxis has even expanded to patients with no prior reaction to intravascular contrast media who are somehow perceived to be at increase risk (e.g. shellfish allergy). Recently, the first large scale prospective study reported exceedingly low incidence of adverse reaction to high oslmolality iodine-containing contrast media administered at the time of ERCP done without prophylactic premedication even in patients considered to be at the highest risk (prior severe reaction to intravascular contrast media administration). These data suggest that the use of prophylactic regiments prior to ERCP appears to be unnecessary. PMID:19275689

  1. Non-toxic lead sulfide nanodots as efficient contrast agents for visualizing gastrointestinal tract.

    PubMed

    Liu, Zhen; Ran, Xiang; Liu, Jianhua; Du, Yingda; Ren, Jinsong; Qu, Xiaogang

    2016-09-01

    Non-invasive imaging of gastrointestinal (GI) tract using novel but efficient contrast agents is of the most important issues in the diagnosis and prognosis of GI diseases. Here, for the first time, we reported the design and synthesis of biothiol-decorated lead sulfide nanodots, as well as their usages in functional dual-modality imaging of GI tract in vivo. Due to the presence of glutathione on the surface of the nanodots, these well-prepared contrast agents could decrease the unwanted ion leakage, withstand the harsh conditions in GI tract, and avoid the systemic absorption after oral administration. Compared with clinical barium meal and iodine-based contrast agents, these nanodots exhibited much more significant enhancement in contrast efficiency during both 2D X-ray imaging and 3D CT imaging. Different from some conventional invasive imaging modalities, such as gastroscope and enteroscope, non-invasive imaging strategy by using glutathione modified PbS nanodots as contrast agents could reduce the painfulness towards patients, facilitate the imaging procedure, and economize the manipulation period. Moreover, long-term toxicity and bio-distribution of these nanodots after oral administration were evaluated in detail, which indicated their overall safety. Based on our present study, these nanodots could act as admirable contrast agents to integrate X-ray imaging and CT imaging for the direct visualization of GI tract. PMID:27240159

  2. Effect of Intravascular Iodinated Contrast Media on Natural Course of End-Stage Renal Disease Progression in Hemodialysis Patients: A Prospective Study

    SciTech Connect

    Janousek, Radim; Krajina, Antonin; Peregrin, Jan H.; Dusilova-Sulkova, Sylvie; Renc, Ondrej; Hajek, Jan; Dvorak, Kamil; Fixa, Petr; Cermakova, Eva

    2010-02-15

    We evaluated the impact of intravascular iodinated contrast medium on residual diuresis in hemodialyzed patients. Two groups of clinically stable hemodialyzed patients with residual diuresis minimally 500 ml of urine per day were studied. The patients from the first group were given iso-osmolal contrast agent iodixanol (Visipaque, GE Healthcare, United Kingdom) in concentration of iodine 320 mg/ml with osmolality 290 mOsm/kg of water during the endovascular procedure. The second control group was followed without contrast medium administered. Residual diuresis and residual renal excretory capacity expressed as 24-h calculated creatinine clearance were evaluated in the both groups after 6 months. The evaluated group included 42 patients who were given 99.3 ml of iodixanol in average (range, 60-180 ml). The control group included 45 patients. There was no statistically significant difference found between both groups in daily volume of urine (P = 0.855) and calculated clearance of creatinine (P = 0.573). We can conclude that residual diuresis is not significantly influenced by intravascular administration of iso-osmolal iodinated contrast agent (iodixanol) in range of volume from 60 to 180 ml in comparison to natural course of urinary output and residual renal function during end-stage renal disease. This result can help the nephrologist to decide which imaging method/contrast medium to use in dialyzed patients in current practice.

  3. A simple method to estimate the optimum iodine concentration of contrast material through microcatheters: hydrodynamic calculation with spreadsheet software

    NASA Astrophysics Data System (ADS)

    Yamauchi, Teiyu; Furui, Shigeru; Suzuki, Shigeru; Mimura, Kohshiro; Hayashi, Toshihiko; Yamada, Takeshi; Futami, Choichiro; Tsukiyama, Yumiko; Harada, Motoko

    2008-03-01

    It is important to increase the iodine delivery rate (I), that is the iodine concentration of the contrast material (C) × the flow rate of the contrast material (Q), through microcatheters to obtain arteriograms of the highest contrast. It is known that C is an important factor that influences I. The purpose of this study is to establish a method of hydrodynamic calculation of the optimum iodine concentration (i.e., the iodine concentration at which I becomes maximum) of the contrast material and its flow rate through commercially available microcatheters. Iopamidol, ioversol and iohexol of ten iodine concentrations were used. Iodine delivery rates (I meas) of each contrast material through ten microcatheters were measured. The calculated iodine delivery rate (I cal) and calculated optimum iodine concentration (calculated C opt) were obtained with spreadsheet software. The agreement between I cal and I meas was studied by correlation and logarithmic Bland-Altman analyses. The value of the calculated C opt was within the optimum range of iodine concentrations (i.e. the range of iodine concentrations at which I meas becomes 90% or more of the maximum) in all cases. A good correlation between I cal and I meas (I cal = 1.08 I meas, r = 0.99) was observed. Logarithmic Bland-Altman analysis showed that the 95% confidence interval of I cal/I meas was between 0.82 and 1.29. In conclusion, hydrodynamic calculation with spreadsheet software is an accurate, generally applicable and cost-saving method to estimate the value of the optimum iodine concentration and its flow rate through microcatheters.

  4. The effect of bilipolinum (Adipiodon), an iodine contrast medium on erythrocyte enzymes.

    PubMed

    Kwiatkowska, J; Kwiatkowska, D; Dawiskiba, J

    1980-01-01

    Bilipolinum (Adipiodon), iodine contrast medium used in cholangiography, showed an inhibitory effect on the activity of human erythrocyte phosphohexoseisomerase, phosphofructokinase, aldolase and glucose-6-phosphate dehydrogenase. The addition of glucose metabolites (glucose-6-phosphate, fructose-6-phosphate, fructose-1,6-bis-phosphate, pyruvate and lactate) abolished the inhibitory effect of Bilipolinum. In the presence of Bilipolinum purified erythrocyte phosphofructokinase showed a decreased affinity towards substrate, modified allosteric properties and reduced stability at pH below 7.5. Purified erythrocyte glucose-6-phosphate dehydrogenase was also affected by Bilipolinum and its affinity for NADP was decreased. Testing of erythrocyte enzymes in the evaluation of toxicity of iodine contrast media is discussed. PMID:6452104

  5. Diffusible iodine-based contrast-enhanced computed tomography (diceCT): an emerging tool for rapid, high-resolution, 3-D imaging of metazoan soft tissues.

    PubMed

    Gignac, Paul M; Kley, Nathan J; Clarke, Julia A; Colbert, Matthew W; Morhardt, Ashley C; Cerio, Donald; Cost, Ian N; Cox, Philip G; Daza, Juan D; Early, Catherine M; Echols, M Scott; Henkelman, R Mark; Herdina, A Nele; Holliday, Casey M; Li, Zhiheng; Mahlow, Kristin; Merchant, Samer; Müller, Johannes; Orsbon, Courtney P; Paluh, Daniel J; Thies, Monte L; Tsai, Henry P; Witmer, Lawrence M

    2016-06-01

    Morphologists have historically had to rely on destructive procedures to visualize the three-dimensional (3-D) anatomy of animals. More recently, however, non-destructive techniques have come to the forefront. These include X-ray computed tomography (CT), which has been used most commonly to examine the mineralized, hard-tissue anatomy of living and fossil metazoans. One relatively new and potentially transformative aspect of current CT-based research is the use of chemical agents to render visible, and differentiate between, soft-tissue structures in X-ray images. Specifically, iodine has emerged as one of the most widely used of these contrast agents among animal morphologists due to its ease of handling, cost effectiveness, and differential affinities for major types of soft tissues. The rapid adoption of iodine-based contrast agents has resulted in a proliferation of distinct specimen preparations and scanning parameter choices, as well as an increasing variety of imaging hardware and software preferences. Here we provide a critical review of the recent contributions to iodine-based, contrast-enhanced CT research to enable researchers just beginning to employ contrast enhancement to make sense of this complex new landscape of methodologies. We provide a detailed summary of recent case studies, assess factors that govern success at each step of the specimen storage, preparation, and imaging processes, and make recommendations for standardizing both techniques and reporting practices. Finally, we discuss potential cutting-edge applications of diffusible iodine-based contrast-enhanced computed tomography (diceCT) and the issues that must still be overcome to facilitate the broader adoption of diceCT going forward. PMID:26970556

  6. [Prophylaxis and treatment of side effects due to iodinated contrast media relevant to radiological practice].

    PubMed

    Becker, C

    2007-09-01

    Increased utilization of iodinated contrast media may be associated with increased incidence of adverse events. The most important side effects include contrast-induced nephropathy, anaphylactoid reaction, thyrotoxicosis, and extravasation. In patients with moderate renal dysfunction, saline hydration and reduction of contrast media volume are recommended. No regime to prevent anaphylactoid reactions has yet proven to be efficient. If subclinical hyperthyroidism has been determined, prophylaxis with sodium perchlorate is advised. Contrast-induced nephropathy is commonly transient and needs to be followed over time. Mild general anaphylactoid reactions may be treated with antihistaminic drugs and corticosteroids. Furthermore the choice of the X-ray contrast media might influence the risk of any adverse effects. PMID:17768601

  7. Dense iodine-rich compounds with low detonation pressures as biocidal agents.

    PubMed

    He, Chunlin; Zhang, Jiaheng; Shreeve, Jean'ne M

    2013-06-01

    Fifteen iodo compounds and six iodyl compounds with an iodine content between 45.3 and 89.0 % were prepared. The mono, di, and triiodyl compounds were obtained from the corresponding iodo compound by employing Oxone. All the compounds were characterized by IR, (1)H and (13)C NMR, elemental analysis, and differential scanning calorimetry (DSC). The impact sensitivity was measured by using BAM (Bundesamt für Materialforschung) methodology. Based on the calculated heats of formation and experimental densities, the detonation properties and detonation products were predicted by employing Cheetah 6.0. A total percentage of iodine-containing species in wt % (I2, HI, and I in gas phase) ranged from 46.7 (21) to 88.94 % (11) was found in the detonation products. The high concentration and easy accessibility of iodine and/or iodine-containing species is very important in developing materials suitable as Agent Defeat Weapons (ADWs). PMID:23576298

  8. Modified natural nanoparticles as contrast agents for medical imaging

    PubMed Central

    Cormode, David P.; Jarzyna, Peter A.; Mulder, Willem J. M.; Fayad, Zahi A.

    2009-01-01

    The development of novel and effective contrast agents is one of the drivers of the ongoing improvement in medical imaging. Many of the new agents reported are nanoparticle-based. There are a variety of natural nanoparticles known, e.g. lipoproteins, viruses or ferritin. Natural nanoparticles have advantages as delivery platforms such as biodegradability. In addition, our understanding of natural nanoparticles is quite advanced, allowing their adaptation as contrast agents. They can be labeled with small molecules or ions such as Gd3+ to act as contrast agents for magnetic resonance imaging, 18F to act as positron emission tomography contrast agents or fluorophores to act as contrast agents for fluorescence techniques. Additionally, inorganic nanoparticles such as iron oxide, gold nanoparticles or quantum dots can be incorporated to add further contrast functionality. Furthermore, these natural nanoparticle contrast agents can be rerouted from their natural targets via the attachment of targeting molecules. In this review, we discuss the various modified natural nanoparticles that have been exploited as contrast agents. PMID:19900496

  9. Basic MR relaxation mechanisms and contrast agent design.

    PubMed

    De León-Rodríguez, Luis M; Martins, André F; Pinho, Marco C; Rofsky, Neil M; Sherry, A Dean

    2015-09-01

    The diagnostic capabilities of magnetic resonance imaging (MRI) have undergone continuous and substantial evolution by virtue of hardware and software innovations and the development and implementation of exogenous contrast media. Thirty years since the first MRI contrast agent was approved for clinical use, a reliance on MR contrast media persists, largely to improve image quality with higher contrast resolution and to provide additional functional characterization of normal and abnormal tissues. Further development of MR contrast media is an important component in the quest for continued augmentation of diagnostic capabilities. In this review we detail the many important considerations when pursuing the design and use of MR contrast media. We offer a perspective on the importance of chemical stability, particularly kinetic stability, and how this influences one's thinking about the safety of metal-ligand-based contrast agents. We discuss the mechanisms involved in MR relaxation in the context of probe design strategies. A brief description of currently available contrast agents is accompanied by an in-depth discussion that highlights promising MRI contrast agents in the development of future clinical and research applications. Our intention is to give a diverse audience an improved understanding of the factors involved in developing new types of safe and highly efficient MR contrast agents and, at the same time, provide an appreciation of the insights into physiology and disease that newer types of responsive agents can provide. PMID:25975847

  10. Inorganic nanoparticle-based contrast agents for molecular imaging

    PubMed Central

    Cho, Eun Chul; Glaus, Charles; Chen, Jingyi; Welch, Michael J.; Xia, Younan

    2010-01-01

    Inorganic nanoparticles including semiconductor quantum dots, iron oxide nanoparticles, and gold nanoparticles have been developed as contrast agents for diagnostics by molecular imaging. Compared to traditional contrast agents, nanoparticles offer several advantages: their optical and magnetic properties can be tailored by engineering the composition, structure, size, and shape; their surfaces can be modified with ligands to target specific biomarkers of disease; the contrast enhancement provided can be equivalent to millions of molecular counterparts; and they can be integrated with a combination of different functions for multi-modal imaging. Here, we review recent advances in the development of contrast agents based on inorganic nanoparticles for molecular imaging, with a touch on contrast enhancement, surface modification, tissue targeting, clearance, and toxicity. As research efforts intensify, contrast agents based on inorganic nanoparticles that are highly sensitive, target-specific, and safe to use are expected to enter clinical applications in the near future. PMID:21074494

  11. INTRAARTERIAL INJECTION OF IODINATED CONTRAST MEDIUM FOR CONTRAST ENHANCED COMPUTED TOMOGRAPHY OF THE EQUINE HEAD.

    PubMed

    Carmalt, James L; Montgomery, James

    2015-01-01

    Minimizing the volume of contrast administered for contrast-enhanced computed tomography (CT) of the equine head is desirable for reducing costs and risks of adverse reactions, however evidence-based studies on the effects of varying volumes on image quality are currently lacking. The objective of the current study was to determine whether low-volume intraarterial administration of contrast medium would result in an equivalent image quality and tissue attenuation vs. high-volume intravenous bolus administration. A prospective cross-over experimental design was used in a sample of six horses. After anesthetic induction, the right carotid artery was exposed surgically and catheterized. Four CT scans of the cranium were performed for each horse: baseline, immediately following intraarterial contrast injection, five-min postinjection (return to baseline) and a final scan after intravenous contrast administration. Soft tissue attenuation in predetermined regions of interest (ROI); and length, width, and height measurements of the pituitary gland were recorded at each time point. Horses were euthanized and measurements of the pituitary gland were repeated postmortem. No adverse reactions to contrast administration were observed. Intraarterial and intravenous administration of contrast medium resulted in significantly greater soft tissue enhancement of some brain ROI's and the pituitary gland vs. baseline values. Pituitary gland measurements made on postcontrast CT images did not differ from those obtained during postmortem examination. Findings indicated that low-dose intraarterial administration of contrast material in the equine head resulted in comparable soft tissue enhancement vs. high volume intravenous administration. PMID:25782997

  12. Diagnostic image quality of hysterosalpingography: ionic versus non ionic water soluble iodinated contrast media

    PubMed Central

    Mohd Nor, H; Jayapragasam, KJ; Abdullah, BJJ

    2009-01-01

    Objective To compare the diagnostic image quality between three different water soluble iodinated contrast media in hysterosalpingography (HSG). Material and method In a prospective randomised study of 204 patients, the diagnostic quality of images obtained after hysterosalpingography were evaluated using Iopramide (106 patients) and Ioxaglate (98 patients). 114 patients who had undergone HSG examination using Iodamide were analysed retrospectively. Image quality was assessed by three radiologists independently based on an objective set of criteria. The obtained results were statistically analysed using Kruskal-Wallis and Mann-Whitney U test. Results Visualisation of fimbrial rugae was significantly better with Iopramide and Ioxaglate than Iodamide. All contrast media provided acceptable diagnostic image quality with regard to uterine, fallopian tubes outline and peritoneal spill. Uterine opacification was noted to be too dense in all three contrast media and not optimal for the assessment of intrauterine pathology. Higher incidence of contrast intravasation was noted in the Iodamide group. Similarly, the numbers of patients diagnosed with bilateral blocked fallopian tubes were also higher in the Iodamide group. Conclusion HSG using low osmolar contrast media (Iopramide and Ioxaglate) demonstrated diagnostic image qualities similar to HSG using conventional high osmolar contrast media (Iodamide). However, all three contrast media were found to be too dense for the detection of intrauterine pathology. Better visualisation of the fimbrial outline using Ioxaglate and Iopramide were attributed to their low contrast viscosity. The increased incidence of contrast media intravasation and bilateral tubal blockage using Iodamide are probably related to the high viscosity. PMID:21611058

  13. Superparamagnetic nanoparticle-inclusion microbubbles for ultrasound contrast agents

    NASA Astrophysics Data System (ADS)

    Yang, Fang; Li, Ling; Li, Yixin; Chen, Zhongping; Wu, Junru; Gu, Ning

    2008-11-01

    We have developed a new type of ultrasound (US) contrast agent, consisting of a gas core, a layer of superparamagnetic iron oxide Fe3O4 nanoparticles (SPIO) and an oil in water outermost layer. The newly developed US contrast agent microbubbles have a mean diameter of 760 nm with a polydisperity index (PI) of 0.699. Our in vitro and in vivo experiments have shown that they have the following advantages compared to gas-encapsulated microbbubbles without SPIO inclusion: (1) they provide better contrast for US images; (2) the SPIO-inclusion microbubbles generate a higher backscattering signal; the mean grey scale is 97.9, which is 38.6 higher than that of microbubbles without SPIO; and (3) since SPIO can also serve as a contrast agent of magnetic resonance images (MRI) in vitro, they can be potentially used as contrast agents for double-modality (MRI and US) clinical studies.

  14. Investigation of optimal parameters for penalized maximum-likelihood reconstruction applied to iodinated contrast-enhanced breast CT

    NASA Astrophysics Data System (ADS)

    Makeev, Andrey; Ikejimba, Lynda; Lo, Joseph Y.; Glick, Stephen J.

    2016-03-01

    Although digital mammography has reduced breast cancer mortality by approximately 30%, sensitivity and specificity are still far from perfect. In particular, the performance of mammography is especially limited for women with dense breast tissue. Two out of every three biopsies performed in the U.S. are unnecessary, thereby resulting in increased patient anxiety, pain, and possible complications. One promising tomographic breast imaging method that has recently been approved by the FDA is dedicated breast computed tomography (BCT). However, visualizing lesions with BCT can still be challenging for women with dense breast tissue due to the minimal contrast for lesions surrounded by fibroglandular tissue. In recent years there has been renewed interest in improving lesion conspicuity in x-ray breast imaging by administration of an iodinated contrast agent. Due to the fully 3-D imaging nature of BCT, as well as sub-optimal contrast enhancement while the breast is under compression with mammography and breast tomosynthesis, dedicated BCT of the uncompressed breast is likely to offer the best solution for injected contrast-enhanced x-ray breast imaging. It is well known that use of statistically-based iterative reconstruction in CT results in improved image quality at lower radiation dose. Here we investigate possible improvements in image reconstruction for BCT, by optimizing free regularization parameter in method of maximum likelihood and comparing its performance with clinical cone-beam filtered backprojection (FBP) algorithm.

  15. Computed tomography lung iodine contrast mapping by image registration and subtraction

    NASA Astrophysics Data System (ADS)

    Goatman, Keith; Plakas, Costas; Schuijf, Joanne; Beveridge, Erin; Prokop, Mathias

    2014-03-01

    Pulmonary embolism (PE) is a relatively common and potentially life threatening disease, affecting around 600,000 people annually in the United States alone. Prompt treatment using anticoagulants is effective and saves lives, but unnecessary treatment risks life threatening haemorrhage. The specificity of any diagnostic test for PE is therefore as important as its sensitivity. Computed tomography (CT) angiography is routinely used to diagnose PE. However, there are concerns it may over-report the condition. Additional information about the severity of an occlusion can be obtained from an iodine contrast map that represents tissue perfusion. Such maps tend to be derived from dual-energy CT acquisitions. However, they may also be calculated by subtracting pre- and post-contrast CT scans. Indeed, there are technical advantages to such a subtraction approach, including better contrast-to-noise ratio for the same radiation dose, and bone suppression. However, subtraction relies on accurate image registration. This paper presents a framework for the automatic alignment of pre- and post-contrast lung volumes prior to subtraction. The registration accuracy is evaluated for seven subjects for whom pre- and post-contrast helical CT scans were acquired using a Toshiba Aquilion ONE scanner. One hundred corresponding points were annotated on the pre- and post-contrast scans, distributed throughout the lung volume. Surface-to-surface error distances were also calculated from lung segmentations. Prior to registration the mean Euclidean landmark alignment error was 2.57mm (range 1.43-4.34 mm), and following registration the mean error was 0.54mm (range 0.44-0.64 mm). The mean surface error distance was 1.89mm before registration and 0.47mm after registration. There was a commensurate reduction in visual artefacts following registration. In conclusion, a framework for pre- and post-contrast lung registration has been developed that is sufficiently accurate for lung subtraction

  16. Iron Oxide as an MRI Contrast Agent for Cell Tracking

    PubMed Central

    Korchinski, Daniel J.; Taha, May; Yang, Runze; Nathoo, Nabeela; Dunn, Jeff F.

    2015-01-01

    Iron oxide contrast agents have been combined with magnetic resonance imaging for cell tracking. In this review, we discuss coating properties and provide an overview of ex vivo and in vivo labeling of different cell types, including stem cells, red blood cells, and monocytes/macrophages. Furthermore, we provide examples of applications of cell tracking with iron contrast agents in stroke, multiple sclerosis, cancer, arteriovenous malformations, and aortic and cerebral aneurysms. Attempts at quantifying iron oxide concentrations and other vascular properties are examined. We advise on designing studies using iron contrast agents including methods for validation. PMID:26483609

  17. Iodinated contrast media electro-degradation: process performance and degradation pathways.

    PubMed

    Del Moro, Guido; Pastore, Carlo; Di Iaconi, Claudio; Mascolo, Giuseppe

    2015-02-15

    The electrochemical degradation of six of the most widely used iodinated contrast media was investigated. Batch experiments were performed under constant current conditions using two DSA® electrodes (titanium coated with a proprietary and patented mixed metal oxide solution of precious metals such as iridium, ruthenium, platinum, rhodium and tantalum). The degradation removal never fell below 85% (at a current density of 64 mA/cm(2) with a reaction time of 150 min) when perchlorate was used as the supporting electrolyte; however, when sulphate was used, the degradation performance was above 80% (at a current density of 64 mA/cm(2) with a reaction time of 150 min) for all of the compounds studied. Three main degradation pathways were identified, namely, the reductive de-iodination of the aromatic ring, the reduction of alkyl aromatic amides to simple amides and the de-acylation of N-aromatic amides to produce aromatic amines. However, as amidotrizoate is an aromatic carboxylate, this is added via the decarboxylation reaction. The investigation did not reveal toxicity except for the lower current density used, which has shown a modest toxicity, most likely for some reaction intermediates that are not further degraded. In order to obtain total removal of the contrast media, it was necessary to employ a current intensity between 118 and 182 mA/cm(2) with energy consumption higher than 370 kWh/m(3). Overall, the electrochemical degradation was revealed to be a reliable process for the treatment of iodinated contrast media that can be found in contaminated waters such as hospital wastewater or pharmaceutical waste-contaminated streams. PMID:25433384

  18. Photodecomposition of iodinated contrast media and subsequent formation of toxic iodinated moieties during final disinfection with chlorinated oxidants.

    PubMed

    Allard, Sébastien; Criquet, Justine; Prunier, Anaïs; Falantin, Cécilia; Le Person, Annaïg; Yat-Man Tang, Janet; Croué, Jean-Philippe

    2016-10-15

    Large amount of iodinated contrast media (ICM) are found in natural waters (up to μg.L(-)(1) levels) due to their worldwide use in medical imaging and their poor removal by conventional wastewater treatment. Synthetic water samples containing different ICM and natural organic matter (NOM) extracts were subjected to UV254 irradiation followed by the addition of chlorine (HOCl) or chloramine (NH2Cl) to simulate final disinfection. In this study, two new quantum yields were determined for diatrizoic acid (0.071 mol.Einstein(-1)) and iotalamic acid (0.038 mol.Einstein(-1)) while values for iopromide (IOP) (0.039 mol.Einstein(-1)), iopamidol (0.034 mol.Einstein(-1)) and iohexol (0.041 mol.Einstein(-1)) were consistent with published data. The photodegradation of IOP led to an increasing release of iodide with increasing UV doses. Iodide is oxidized to hypoiodous acid (HOI) either by HOCl or NH2Cl. In presence of NOM, the addition of oxidant increased the formation of iodinated disinfection by-products (I-DBPs). On one hand, when the concentration of HOCl was increased, the formation of I-DBPs decreased since HOI was converted to iodate. On the other hand, when NH2Cl was used the formation of I-DBPs was constant for all concentration since HOI reacted only with NOM to form I-DBPs. Increasing the NOM concentration has two effects, it decreased the photodegradation of IOP by screening effect but it increased the number of reactive sites available for reaction with HOI. For experiments carried out with HOCl, increasing the NOM concentration led to a lower formation of I-DBPs since less IOP are photodegraded and iodate are formed. For NH2Cl the lower photodegradation of IOP is compensated by the higher amount of NOM reactive sites, therefore, I-DBPs concentrations were constant for all NOM concentrations. 7 different NOM extracts were tested and almost no differences in IOP degradation and I-DBPs formation was observed. Similar behaviour was observed for the 5 ICM

  19. In vivo small animal micro-CT using nanoparticle contrast agents

    PubMed Central

    Ashton, Jeffrey R.; West, Jennifer L.; Badea, Cristian T.

    2015-01-01

    Computed tomography (CT) is one of the most valuable modalities for in vivo imaging because it is fast, high-resolution, cost-effective, and non-invasive. Moreover, CT is heavily used not only in the clinic (for both diagnostics and treatment planning) but also in preclinical research as micro-CT. Although CT is inherently effective for lung and bone imaging, soft tissue imaging requires the use of contrast agents. For small animal micro-CT, nanoparticle contrast agents are used in order to avoid rapid renal clearance. A variety of nanoparticles have been used for micro-CT imaging, but the majority of research has focused on the use of iodine-containing nanoparticles and gold nanoparticles. Both nanoparticle types can act as highly effective blood pool contrast agents or can be targeted using a wide variety of targeting mechanisms. CT imaging can be further enhanced by adding spectral capabilities to separate multiple co-injected nanoparticles in vivo. Spectral CT, using both energy-integrating and energy-resolving detectors, has been used with multiple contrast agents to enable functional and molecular imaging. This review focuses on new developments for in vivo small animal micro-CT using novel nanoparticle probes applied in preclinical research. PMID:26581654

  20. Torsten Almén (1931-2016): the father of non-ionic iodine contrast media.

    PubMed

    Nyman, Ulf; Ekberg, Olle; Aspelin, Peter

    2016-09-01

    The Swedish radiologist Torsten Almén is the first clinical radiologist ever to have made a fundamental contribution to intravascular contrast medium design, the development of non-ionic contrast media. He became emotionally triggered by the patients' severe pain each time he injected the ionic "high-osmolar" contrast media when performing peripheral arteriographies in the early 1960s. One day he got a flash of genius that combined the observation of pain, a pathophysiological theory and how to eliminate it with suitable contrast media chemistry. After self-studies in chemistry he developed the concept of iodine contrast media not dissociating into ions in solution to reduce their osmolality and even reach plasma isotonicity. He offered several pharmaceutical companies his concept of mono- and polymeric non-ionic agents but without response, since it was considered against the chemical laws of that time. Contrast media constructed as salts and dissociating into ions in solution was regarded an absolute necessity to achieve high enough water solubility and concentration for diagnostic purposes. Finally a small Norwegian company, Nyegaard & Co., took up his idea 1968 and together they developed the essentially painless "low-osmolar" monomeric non-ionic metrizamide (Amipaque) released in 1974 and iohexol (Omipaque) in 1982 followed by the "iso-osmolar" dimeric non-ionic iodixanol (Visipaque) released in 1993. This has implied a profound paradigm shift with regard to reduction of both hypertonic and chemotoxic side effects, which have been a prerequisite for the today's widespread use of contrast medium-enhanced CT and advanced endovascular interventional techniques even in fragile patients. PMID:27225455

  1. Microbubbles as contrast agent for in-line x-ray phase-contrast imaging

    SciTech Connect

    Xi Yan; Zhao Jun; Tang Rongbiao; Wang Yujie

    2011-07-04

    In the present study, we investigated the potential of gas-filled microbubbles as contrast agents for in-line x-ray phase-contrast imaging (PCI) in biomedical applications. When imaging parameters are optimized, the microbubbles function as microlenses that focus the incoming x-rays to form bright spots, which can significantly enhance the image contrast. Since microbubbles have been shown to be safe contrast agents in clinical ultrasonography, this contrast-enhancement procedure for PCI may have promising utility in biomedical applications, especially when the dose of radiation is a serious concern. In this study, we performed both numerical simulations and ex vivo experiments to investigate the formation of the contrast and the effectiveness of microbubbles as contrast agents in PCI.

  2. MRI contrast agent concentration and tumor interstitial fluid pressure.

    PubMed

    Liu, L J; Schlesinger, M

    2016-10-01

    The present work describes the relationship between tumor interstitial fluid pressure (TIFP) and the concentration of contrast agent for dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). We predict the spatial distribution of TIFP based on that of contrast agent concentration. We also discuss the cases for estimating tumor interstitial volume fraction (void fraction or porosity of porous medium), ve, and contrast volume transfer constant, K(trans), by measuring the ratio of contrast agent concentration in tissue to that in plasma. A linear fluid velocity distribution may reflect a quadratic function of TIFP distribution and lead to a practical method for TIFP estimation. To calculate TIFP, the parameters or variables should preferably be measured along the direction of the linear fluid velocity (this is in the same direction as the gray value distribution of the image, which is also linear). This method may simplify the calculation for estimating TIFP. PMID:27343032

  3. A brief account of nanoparticle contrast agents for photoacoustic imaging.

    PubMed

    Pan, Dipanjan; Kim, Benjamin; Wang, Lihong V; Lanza, Gregory M

    2013-01-01

    Photoacoustic imaging (PAI) is a hybrid, nonionizing modality offering excellent spatial resolution, deep penetration, and high soft tissue contrast. In PAI, signal is generated based on the absorption of laser-generated optical energy by endogenous tissues or exogenous contrast agents leading to acoustic emissions detected by an ultrasound transducer. Research in this area over the years has shown that PAI has the ability to provide both physiological and molecular imaging, which can be viewed alone or used in a hybrid modality fashion to extend the anatomic and hemodynamic sensitivities of clinical ultrasound. PAI may be performed using inherent contrast afforded by light absorbing molecules such as hemoglobin, myoglobin, and melanin or exogenous small molecule contrast agent such as near infrared dyes and porphyrins. However, this review summarizes the potential of exogenous nanoparticle-based agents for PAI applications including contrast based on gold particles, carbon nanotubes, and encapsulated copper compounds. PMID:23983210

  4. A Brief Account of Nanoparticle Contrast Agents for Photoacoustic Imaging

    PubMed Central

    Pan, Dipanjan; Kim, Benjamin; Wang, Lihong V.; Lanza, Gregory M

    2014-01-01

    Photoacoustic imaging (PAI) is a hybrid, nonionizing modality offering excellent spatial resolution, deep penetration, and high soft tissue contrast. In PAI, signal is generated based on the absorption of laser-generated optical energy by endogenous tissues or exogenous contrast agents leading to acoustic emissions detected by an ultrasound transducer. Research in this area over the years has shown that PAI has the ability to provide both physiological and molecular imaging, which can be viewed alone or used in a hybrid modality fashion to extend the anatomic and hemodynamic sensitivities of clinical ultrasound. PAI may be performed using inherent contrast afforded by light absorbing molecules such as hemoglobin, myoglobin, and melanin or exogenous small molecule contrast agent such as near infrared dyes and porphyrins. However, this review summarizes the potential of exogenous nanoparticle-based agents for PAI applications including contrast based on gold particles, carbon nanotubes, and encapsulated copper compounds. PMID:23983210

  5. [Allergy to iodinated drugs and to foods rich in iodine: Iodine is not the allergenic determinant].

    PubMed

    Dewachter, Pascale; Mouton-Faivre, Claudie

    2015-11-01

    "Iodine allergy" does not exist. The concept of "iodine allergy" should be abandoned since it may result in inappropriate measures such as drug, food or environmental eviction. Immediate or non-immediate allergic hypersensitivity to iodinated contrast media is not infrequent. The corresponding allergens have not been identified. Iodine is not involved. Immediate or non-immediate allergic hypersensitivity to povidone iodine is rare. The corresponding allergen is povidone in case of immediate hypersensitivity while nonoxynol might be involved during non-immediate hypersensitivity. Seafood allergens belong to a group of muscle proteins. Immediate drug hypersensitivity or food hypersensitivity is assessed by immediate-reading skin tests while non-immediate drug hypersensitivity is investigated by delayed-reading skin testing. Combined histamine and tryptase measurement is invaluable during the diagnostic approach of immediate hypersensitivity. Other biological tests are being evaluated. Allergic hypersensitivity to iodinated contrast agents does not contraindicate the use of other iodinated drugs. PMID:26387623

  6. Multiwalled carbon nanotube hybrids as MRI contrast agents

    PubMed Central

    Tomczyk, Mateusz Michał

    2016-01-01

    Summary Magnetic resonance imaging (MRI) is one of the most commonly used tomography techniques in medical diagnosis due to the non-invasive character, the high spatial resolution and the possibility of soft tissue imaging. Contrast agents, such as gadolinium complexes and superparamagnetic iron oxides, are administered to spotlight certain organs and their pathologies. Many new models have been proposed that reduce side effects and required doses of these already clinically approved contrast agents. These new candidates often possess additional functionalities, e.g., the possibility of bioactivation upon action of particular stimuli, thus serving as smart molecular probes, or the coupling with therapeutic agents and therefore combining both a diagnostic and therapeutic role. Nanomaterials have been found to be an excellent scaffold for contrast agents, among which carbon nanotubes offer vast possibilities. The morphology of multiwalled carbon nanotubes (MWCNTs), their magnetic and electronic properties, the possibility of different functionalization and the potential to penetrate cell membranes result in a unique and very attractive candidate for a new MRI contrast agent. In this review we describe the different issues connected with MWCNT hybrids designed for MRI contrast agents, i.e., their synthesis and magnetic and dispersion properties, as well as both in vitro and in vivo behavior, which is important for diagnostic purposes. An introduction to MRI contrast agent theory is elaborated here in order to point to the specific expectations regarding nanomaterials. Finally, we propose a promising, general model of MWCNTs as MRI contrast agent candidates based on the studies presented here and supported by appropriate theories. PMID:27547627

  7. Multiwalled carbon nanotube hybrids as MRI contrast agents.

    PubMed

    Kuźnik, Nikodem; Tomczyk, Mateusz Michał

    2016-01-01

    Magnetic resonance imaging (MRI) is one of the most commonly used tomography techniques in medical diagnosis due to the non-invasive character, the high spatial resolution and the possibility of soft tissue imaging. Contrast agents, such as gadolinium complexes and superparamagnetic iron oxides, are administered to spotlight certain organs and their pathologies. Many new models have been proposed that reduce side effects and required doses of these already clinically approved contrast agents. These new candidates often possess additional functionalities, e.g., the possibility of bioactivation upon action of particular stimuli, thus serving as smart molecular probes, or the coupling with therapeutic agents and therefore combining both a diagnostic and therapeutic role. Nanomaterials have been found to be an excellent scaffold for contrast agents, among which carbon nanotubes offer vast possibilities. The morphology of multiwalled carbon nanotubes (MWCNTs), their magnetic and electronic properties, the possibility of different functionalization and the potential to penetrate cell membranes result in a unique and very attractive candidate for a new MRI contrast agent. In this review we describe the different issues connected with MWCNT hybrids designed for MRI contrast agents, i.e., their synthesis and magnetic and dispersion properties, as well as both in vitro and in vivo behavior, which is important for diagnostic purposes. An introduction to MRI contrast agent theory is elaborated here in order to point to the specific expectations regarding nanomaterials. Finally, we propose a promising, general model of MWCNTs as MRI contrast agent candidates based on the studies presented here and supported by appropriate theories. PMID:27547627

  8. Gadolinium-Based Contrast Agent Accumulation and Toxicity: An Update.

    PubMed

    Ramalho, J; Semelka, R C; Ramalho, M; Nunes, R H; AlObaidy, M; Castillo, M

    2016-07-01

    In current practice, gadolinium-based contrast agents have been considered safe when used at clinically recommended doses in patients without severe renal insufficiency. The causal relationship between gadolinium-based contrast agents and nephrogenic systemic fibrosis in patients with renal insufficiency resulted in new policies regarding the administration of these agents. After an effective screening of patients with renal disease by performing either unenhanced or reduced-dose-enhanced studies in these patients and by using the most stable contrast agents, nephrogenic systemic fibrosis has been largely eliminated since 2009. Evidence of in vivo gadolinium deposition in bone tissue in patients with normal renal function is well-established, but recent literature showing that gadolinium might also deposit in the brain in patients with intact blood-brain barriers caught many individuals in the imaging community by surprise. The purpose of this review was to summarize the literature on gadolinium-based contrast agents, tying together information on agent stability and animal and human studies, and to emphasize that low-stability agents are the ones most often associated with brain deposition. PMID:26659341

  9. Optical characterization of contrast agents for optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Lee, Tin-Man; Toublan, Farah J.; Oldenburg, Amy; Sitafalwalla, Shoeb; Luo, Wei; Marks, Daniel L.; Suslick, Kenneth S.; Boppart, Stephen A.

    2003-07-01

    The use of contrast agents in almost every imaging modality has been known to enhance the sensitivity of detection and improve diagnostic capabilities by site-specifically labeling tissues or cells of interest. The imaging capabilities of Optical Coherence Tomography (OCT) need to be improved in order to detect early neoplastic changes in medicine and tumor biology. We introduce and characterize the optical properties of several types of optical contrast agents in OCT, namely encapsulating microspheres that incorporate materials including melanin, gold, and carbon. Micron-sized microspheres have been fabricated by state-of-the-art sonicating and ultrasound technology. The optical properties of optical contrast agents have been characterized according to their scattering and absorption coefficients and lifetimes using OCT and the oblique incidence reflectometry method. Finally, we demonstrate the use of these optical contrast agents in in vitro mice liver and analyze the contrast improvement from the OCT images. These optical contrast agents have the potential to improve the detection of in vivo pathologies in the future.

  10. Micro-Radiography of Living Biological Organisms with MEDIPIX2 Detector and Application of Various Contrast Agents

    NASA Astrophysics Data System (ADS)

    Dammer, Jiri; Sopko, Vit; Jakubek, Jan; Weyda, Frantisek; Benes, Jiri; Zahorovsky, Julian

    2012-08-01

    We describe a newly developed radiographic system equipped with Medipix2 semiconductor pixel detector and a micro-focus FeinFocus X-ray tube tabletop. The detector is used as an imager that counts individual photons of ionizing radiation, emitted by the X-ray tube. The digital pixel detectors of the Medipix family represent a highly efficient type of imaging devices with high spatial resolution better than 1μm, and unlimited dynamic range allowing single particle of radiation and to determine their energies. The setup is particularly suitable for radiographic imaging of small biological samples, including in vivo observations with various contrast agents (iodine and lanthanum nitrate). Along with the description of the apparatus we provide examples of application of iodine and lanthanum nitrate contrast agents as tracers in various insects as model organisms. The iodine contrast agent increases the absorption of X-rays and this leads to better resolution of internal structures of biological organisms, and especially the various cavities, pores, etc. Micro-radiographic imaging helps to detect organisms living in a not visible environment, visualize internal biological processes and also to resolve the details of their body (morphology). Tiny live insects are an ideal object for our studies.

  11. Targeting cancer chemotherapeutic agents by use of lipiodol contrast medium

    SciTech Connect

    Konno, T. )

    1990-11-01

    Arterially administered Lipiodol Ultrafluid contrast medium selectively remained in various malignant solid tumors because of the difference in time required for the removal of Lipiodol contrast medium from normal capillaries and tumor neovasculature. Although blood flow was maintained in the tumor, even immediately after injection Lipiodol contrast medium remained in the neovasculature of the tumor. To target anti-cancer agents to tumors by using Lipiodol contrast medium as a carrier, the characteristics of the agents were examined. Anti-cancer agents had to be soluble in Lipiodol, be stable in it, and separate gradually from it so that the anti-cancer agents would selectively remain in the tumor. These conditions were found to be necessary on the basis of the measurement of radioactivity in VX2 tumors implanted in the liver of 16 rabbits that received arterial injections of 14C-labeled doxorubicin. Antitumor activities and side effects of arterial injections of two types of anti-cancer agents were compared in 76 rabbits with VX2 tumors. Oily anti-cancer agents that had characteristics essential for targeting were compared with simple mixtures of anti-cancer agents with Lipiodol contrast medium that did not have these essential characteristics. Groups of rabbits that received oily anti-cancer agents responded significantly better than groups that received simple mixtures, and side effects were observed more frequently in the groups that received the simple mixtures. These results suggest that targeting of the anti-cancer agent to the tumor is important for treatment of solid malignant tumors.

  12. Chlorotoxin-modified macromolecular contrast agent for MRI tumor diagnosis.

    PubMed

    Huang, Rongqin; Han, Liang; Li, Jianfeng; Liu, Shuhuan; Shao, Kun; Kuang, Yuyang; Hu, Xing; Wang, Xuxia; Lei, Hao; Jiang, Chen

    2011-08-01

    Clinical diagnosis of cancers using magnetic resonance imaging (MRI) is highly dependent on contrast agents, especially for brain tumors which contain blood-brain barrier (BBB) at the early stage. However, currently mostly used low molecular weight contrast agents such as Gd-DTPA suffer from rapid renal clearance, non-specificity, and low contrast efficiency. The aim of this paper is to investigate the potential of a macromolecular MRI contrast agent based on dendrigraft poly-l-lysines (DGLs), using chlorotoxin (CTX) as a tumor-specific ligand. The contrast agent using CTX-modified conjugate as the main scaffold and Gd-DTPA as the payload was successfully synthesized. The results of fluorescent microscopy showed that the modification of CTX could markedly enhance the cellular uptake in C6 glioma and liver tumor cell lines, but not in normal cell line. Significantly increased accumulation of CTX-modified conjugate within glioma and liver tumor was further demonstrated in tumor-bearing nude mice using in vivo imaging system. The MRI results showed that the signal enhancement of mice treated with CTX-modified contrast reached peak level at 5 min for both glioma and liver tumor, 144.97% ± 19.54% and 158.69% ± 12.41%, respectively, significantly higher than that of unmodified counterpart and commercial control. And most importantly, the signal enhancement of CTX-modified contrast agent maintained much longer compared to that of controls, which might be useful for more exact diagnosis for tumors. CTX-modified dendrimer-based conjugate might be applied as an efficient MRI contrast agent for targeted and accurate tumor diagnosis. This finding is especially important for tumors such as brain glioma which is known hard to be diagnosed due to the presence of BBB. PMID:21531455

  13. Selective imaging of adherent targeted ultrasound contrast agents

    PubMed Central

    Zhao, S; Kruse, D E; Ferrara, K W; Dayton, P A

    2007-01-01

    The goal of ultrasonic molecular imaging is the detection of targeted contrast agents bound to receptors on endothelial cells. We propose imaging methods that can distinguish adherent microbubbles from tissue and from freely circulating microbubbles, each of which would otherwise obscure signal from molecularly targeted adherent agents. The methods are based on a harmonic signal model of the returned echoes over a train of pulses. The first method utilizes an ‘image–push–image’ pulse sequence where adhesion of contrast agents is rapidly promoted by acoustic radiation force and the presence of adherent agents is detected by the signal change due to targeted microbubble adhesion. The second method rejects tissue echoes using a spectral high-pass filter. Free agent signal is suppressed by a pulse-to-pulse low-pass filter in both methods. An overlay of the adherent and/or flowing contrast agents on B-mode images can be readily created for anatomical reference. Contrast-to-tissue ratios from adherent microbubbles exceeding 30 dB and 20 dB were achieved for the two methods proposed, respectively. The performance of these algorithms is compared, emphasizing the significance and potential applications in ultrasonic molecular imaging. PMID:17404455

  14. Contrast Agents for Photoacoustic and Thermoacoustic Imaging: A Review

    PubMed Central

    Wu, Dan; Huang, Lin; Jiang, Max S.; Jiang, Huabei

    2014-01-01

    Photoacoustic imaging (PAI) and thermoacoustic imaging (TAI) are two emerging biomedical imaging techniques that both utilize ultrasonic signals as an information carrier. Unique advantages of PAI and TAI are their abilities to provide high resolution functional information such as hemoglobin and blood oxygenation and tissue dielectric properties relevant to physiology and pathology. These two methods, however, may have a limited detection depth and lack of endogenous contrast. An exogenous contrast agent is often needed to effectively resolve these problems. Such agents are able to greatly enhance the imaging contrast and potentially break through the imaging depth limit. Furthermore, a receptor-targeted contrast agent could trace the molecular and cellular biological processes in tissues. Thus, photoacoustic and thermoacoustic molecular imaging can be outstanding tools for early diagnosis, precise lesion localization, and molecular typing of various diseases. The agents also could be used for therapy in conjugation with drugs or in photothermal therapy, where it functions as an enhancer for the integration of diagnosis and therapy. In this article, we present a detailed review about various exogenous contrast agents for photoacoustic and thermoacoustic molecular imaging. In addition, challenges and future directions of photoacoustic and thermoacoustic molecular imaging in the field of translational medicine are also discussed. PMID:25530615

  15. Prevention and Management of Adverse Reactions Induced by Iodinated Contrast Media.

    PubMed

    Wu, Yi Wei; Leow, Kheng Song; Zhu, Yujin; Tan, Cher Heng

    2016-04-01

    Iodinated radiocontrast media (IRCM) is widely used in current clinical practice. Although IRCM is generally safe, serious adverse drug reactions (ADRs) may still occur. IRCM-induced ADRs may be subdivided into chemotoxic and hypersensitivity reactions. Several factors have been shown to be associated with an increased risk of ADRs, including previous contrast media reactions, history of asthma and allergic disease, etc. Contrast media with lower osmolality is generally recommended for at-risk patients to prevent ADRs. Current premedication prophylaxis in at-risk patients may reduce the risk of ADRs. However, there is still a lack of consensus on the prophylactic role of premedication. Contrast-induced nephropathy (CIN) is another component of IRCM-related ADRs. Hydration remains the mainstay of CIN prophylaxis in at-risk patients. Despite several preventive measures, ADRs may still occur. Treatment strategies for potential contrast reactions are also summarised in this article. This article summarises the pathophysiology, epidemiology and risk factors of ADRs with emphasis on prevention and treatment strategies. This will allow readers to understand the rationale behind appropriate patient preparation for diagnostic imaging involving IRCM. PMID:27292007

  16. Exogenous contrast agents for thermoacoustic imaging: An investigation into the underlying sources of contrast

    SciTech Connect

    Ogunlade, Olumide Beard, Paul

    2015-01-15

    Purpose: Thermoacoustic imaging at microwave excitation frequencies is limited by the low differential contrast exhibited by high water content tissues. To overcome this, exogenous thermoacoustic contrast agents based on gadolinium compounds, iron oxide, and single wall carbon nanotubes have previously been suggested and investigated. However, these previous studies did not fully characterize the electric, magnetic, and thermodynamic properties of these agents thus precluding identification of the underlying sources of contrast. To address this, measurements of the complex permittivity, complex permeability, DC conductivity, and Grüneisen parameter have been made. These measurements allowed the origins of the contrast provided by each substance to be identified. Methods: The electric and magnetic properties of the contrast agents were characterized at 3 GHz using two rectangular waveguide cavities. The DC conductivity was measured separately using a conductivity meter. Thermoacoustic signals were then acquired and compared to those generated in water. Finally, 3D electromagnetic simulations were used to decouple the different contributions to the absorbed power density. Results: It was found that the gadolinium compounds provided appreciable electric contrast but not originating from the gadolinium itself. The contrast was either due to dissociation of the gadolinium salt which increased ionic conductivity or its nondissociated polar fraction which increased dielectric polarization loss or a combination of both. In addition, very high concentrations were required to achieve appreciable contrast, to the extent that the Grüneisen parameter increased significantly and became a source of contrast. Iron oxide particles were found to produce low but measurable dielectric contrast due to dielectric polarization loss, but this is attributed to the coating of the particles not the iron oxide. Single wall carbon nanotubes did not provide measurable contrast of any type

  17. Graphene-based contrast agents for photoacoustic and thermoacoustic tomography☆

    PubMed Central

    Lalwani, Gaurav; Cai, Xin; Nie, Liming; Wang, Lihong V.; Sitharaman, Balaji

    2013-01-01

    In this work, graphene nanoribbons and nanoplatelets were investigated as contrast agents for photoacoustic and thermoacoustic tomography (PAT and TAT). We show that oxidized single- and multi-walled graphene oxide nanoribbons (O-SWGNRs, O-MWGNRs) exhibit approximately 5–10 fold signal enhancement for PAT in comparison to blood at the wavelength of 755 nm, and approximately 10–28% signal enhancement for TAT in comparison to deionized (DI) water at 3 GHz. Oxidized graphite microparticles (O-GMPs) and exfoliated graphene oxide nanoplatelets (O-GNPs) show no significant signal enhancement for PAT, and approximately 12–29% signal enhancement for TAT. These results indicate that O-GNRs show promise as multi-modal PAT and TAT contrast agents, and that O-GNPs are suitable contrast agents for TAT. PMID:24490141

  18. Ultrasound contrast agents and their use in monitoring therapy

    NASA Astrophysics Data System (ADS)

    Ferrara, Katherine; Dayton, Paul; Shortencarrier, Michaelann; Kruse, Dustin

    2003-10-01

    The shell of ultrasound contrast agents can be modified to include a molecular targeting ligand, and the properties of the agent with and without molecular targeting can be used to monitor changes produced by a therapy. We have investigated the use of ligands targeted to an integrin expressed in cancer, whose expression correlates with tumor grade. Acoustic studies illustrate a 3- to 20-fold increase in echo amplitude from integrin-expressing cells exposed to the targeted contrast agent, as compared to controls, and depending on cell type, stimulation, and targeting ligand. Changes in integrin expression with therapy may be important in future studies. We have also developed a system to quantify small changes in vascular parameters due to effects of new anti-angiogenic drugs using the intrinsic properties of contrast agents. Regions containing intravascular contrast agents are identified using a strategy that combines subharmonic and phase inversion imaging. As predicted by a Rayleigh-Plesset analysis, this strategy can successfully detect flow over a range of transmission frequencies from 4-6 MHz. We demonstrate that regions of viable tumor as small as 1 mm, as verified by histology, can be detected and show similar morphology to images acquired with computed tomography (CT).

  19. Influence of radiographic contrast agents on quantitative coronary angiography

    SciTech Connect

    Jost, Stefan; Hausmann, Dirk; Lippolt, Peter; Gerhardt, Uwe; Lichtlen, Paul R.

    1997-01-15

    Purpose. Quantitative angiographic studies on the vasomotility of epicardial coronary arteries are gaining increasing relevance. We investigated whether radiographic contrast agents might influence coronary vasomotor tone and thereby the results of such studies. Methods. Coronary angiograms were taken in 12 patients with coronary artery disease at intervals of 5, 3, 2, and 1 min with the low-osmolar, nonionic contrast agent iopamidol 300, and were repeated at identical intervals with the high-osmolar, ionic agent diatrizoate 76%. Results. Quantitative cine film analysis demonstrated no significant diameter changes in angiographically normal and stenotic coronary arteries with iopamidol. With diatrizoate, however, normal segments were dilated 2%{+-}2% (p<0.01) after 2 min and 10%{+-}3% after the 1 min interval (p<0.001). Stenoses showed no uniform responses to diatrizoate. Conclusion. Low-osmolar, nonionic contrast agents should be preferred for quantitative angiographic studies on epicardial coronary vasomotility. When using ionic contrast agents, injection intervals of at least 3 min are required.

  20. Gd-HOPO Based High Relaxivity MRI Contrast Agents

    SciTech Connect

    Datta, Ankona; Raymond, Kenneth

    2008-11-06

    Tris-bidentate HOPO-based ligands developed in our laboratory were designed to complement the coordination preferences of Gd{sup 3+}, especially its oxophilicity. The HOPO ligands provide a hexadentate coordination environment for Gd{sup 3+} in which all he donor atoms are oxygen. Because Gd{sup 3+} favors eight or nine coordination, this design provides two to three open sites for inner-sphere water molecules. These water molecules rapidly exchange with bulk solution, hence affecting the relaxation rates of bulk water olecules. The parameters affecting the efficiency of these contrast agents have been tuned to improve contrast while still maintaining a high thermodynamic stability for Gd{sup 3+} binding. The Gd- HOPO-based contrast agents surpass current commercially available agents ecause of a higher number of inner-sphere water molecules, rapid exchange of inner-sphere water molecules via an associative mechanism, and a long electronic relaxation time. The contrast enhancement provided by these agents is at least twice that of commercial contrast gents, which are based on polyaminocarboxylate ligands.

  1. Microfabricated High-Moment Micrometer-sized MRI Contrast Agents

    PubMed Central

    Zabow, Gary; Dodd, Stephen J.; Shapiro, Erik; Moreland, John; Koretsky, Alan P.

    2010-01-01

    While chemically synthesized superparamagnetic microparticles have enabled much new research based on MRI-tracking of magnetically labeled cells, signal-to-noise levels still limit the potential range of applications. Here it is shown how, through top-down microfabrication, contrast agent relaxivity can be increased several-fold, which should extend the sensitivity of such cell tracking studies. Microfabricated agents can benefit from both higher magnetic moments and higher uniformity than their chemically synthesized counterparts, implying increased label visibility and more quantitative image analyses. To assess the performance of microfabricated micrometer-sized contrast agent particles, analytic models and numerical simulations are developed and tested against new microfabricated agents described in this paper, as well as against results of previous imaging studies of traditional chemically synthesized microparticle agents. Experimental data showing signal effects of 500-nanometer thick, 2-micrometer diameter, gold-coated iron and gold-coated nickel disks verify the simulations. Additionally, it is suggested that measures of location better than the pixel resolution can be obtained and that these are aided using well-defined contrast agent particles achievable through microfabrication techniques. PMID:20928829

  2. Bismuth@US-tubes as a Potential Contrast Agent for X-ray Imaging Applications

    PubMed Central

    Rivera, Eladio J.; Tran, Lesa A.; Hernández-Rivera, Mayra; Yoon, Diana; Mikos, Antonios G.; Rusakova, Irene A.; Cheong, Benjamin Y.; Cabreira-Hansen, Maria da Graça; Willerson, James T.; Perin, Emerson C.; Wilson, Lon J.

    2013-01-01

    The encapsulation of bismuth as BiOCl/Bi2O3 within ultra-short (ca. 50 nm) single-walled carbon nanocapsules (US-tubes) has been achieved. The Bi@US-tubes have been characterized by high-resolution transmission electron microscopy (HR-TEM), energy-dispersive X-ray spectroscopy (EDS), thermogravimetric analysis (TGA), X-ray photoelectron spectroscopy (XPS), and Raman spectroscopy. Bi@US-tubes have been used for intracellular labeling of pig bone marrow-derived mesenchymal stem cells (MSCs) to show high X-ray contrast in computed tomography (CT) cellular imaging for the first time. The relatively high contrast is achieved with low bismuth loading (2.66% by weight) within the US-tubes and without compromising cell viability. X-ray CT imaging of Bi@US-tubes-labeled MSCs showed a nearly two-fold increase in contrast enhancement when compared to unlabeled MSCs in a 100 kV CT clinical scanner. The CT signal enhancement from the Bi@US-tubes is 500 times greater than polymer-coated Bi2S3 nanoparticles and several-fold that of any clinical iodinated contrast agent (CA) at the same concentration. Our findings suggest that the Bi@US-tubes can be used as a potential new class of X-ray CT agent for stem cell labeling and possibly in vivo tracking. PMID:24288589

  3. Revisiting an old friend: manganese-based MRI contrast agents

    PubMed Central

    Pan, Dipanjan; Caruthers, Shelton D.; Senpan, Angana; Schmieder, Ann H.; Wickline, Samuel A.; Lanza, Gregory M.

    2011-01-01

    Non-invasive cellular and molecular imaging techniques are emerging as a multidisciplinary field that offers promise in understanding the components, processes, dynamics and therapies of disease at a molecular level. Magnetic resonance imaging (MRI) is an attractive technique due to the absence of radiation and high spatial resolution which makes it advantageous over techniques involving radioisotopes. Typically paramagnetic and superparamagnetic metals are used as contrast materials for MR based techniques. Gadolinium has been the predominant paramagnetic contrast metal until the discovery and association of the metal with nephrogenic systemic fibrosis (NSF) in some patients with severe renal or kidney disease. Manganese was one of the earliest reported examples of paramagnetic contrast material for MRI because of its efficient positive contrast enhancement. In this review manganese based contrast agent approaches will be presented with a particular emphasis on nanoparticulate agents. We have discussed both classically used small molecule based blood pool contrast agents and recently developed innovative nanoparticle-based strategies highlighting a number of successful molecular imaging examples. PMID:20860051

  4. Impact of Iodinated Contrast on Renal Function and Hemodynamics in Rats with Chronic Hyperglycemia and Chronic Kidney Disease

    PubMed Central

    Fernandes, Sheila Marques; Martins, Daniel Malisani; da Fonseca, Cassiane Dezoti; Watanabe, Mirian; Vattimo, Maria de Fátima Fernandes

    2016-01-01

    Iodinated contrast (IC) is clinically used in diagnostic and interventional procedures, but its use can result in contrast-induced acute kidney injury (CI-AKI). Chronic kidney disease (CKD) and chronic hyperglycemia (CH) are important predisposing factors to CI-AKI. The aim of this study was to investigate the impact of iodinated contrast on the renal function and hemodynamics in rats with chronic hyperglycemia and chronic kidney disease. A total of 30 rats were divided into six groups; Sham: control of chronic renal disease; Citrate: control of chronic hyperglycemia (CH); Nx5/6: rats with 5/6 nephrectomy; Chronic Hyperglycemia: rats receiving Streptozotocin 65 mg/kg; Nx5/6 + IC: rats Nx5/6 received 6 mL/kg of IC; CH + IC: Chronic hyperglycemia rats receiving 6 mL/kg of IC. Renal function (inulin clearance; urinary neutrophil gelatinase-associated lipocalin, NGAL) and hemodynamics (arterial blood pressure; renal blood flow; renal vascular resistance) were evaluated. Iodinated contrast significantly increased urinary NGAL and reduced inulin clearance, while the hemodynamics parameters showed changes in arterial blood pressure, renal blood flow, and renal vascular resistance in both CKD and CH groups. The results suggest that the iodinated contrast in risk factors models has important impact on renal function and hemodynamics. NGAL was confirmed to play a role of highlight in diagnosis of CI-AKI. PMID:27034930

  5. Impact of Iodinated Contrast on Renal Function and Hemodynamics in Rats with Chronic Hyperglycemia and Chronic Kidney Disease.

    PubMed

    Fernandes, Sheila Marques; Martins, Daniel Malisani; da Fonseca, Cassiane Dezoti; Watanabe, Mirian; Vattimo, Maria de Fátima Fernandes

    2016-01-01

    Iodinated contrast (IC) is clinically used in diagnostic and interventional procedures, but its use can result in contrast-induced acute kidney injury (CI-AKI). Chronic kidney disease (CKD) and chronic hyperglycemia (CH) are important predisposing factors to CI-AKI. The aim of this study was to investigate the impact of iodinated contrast on the renal function and hemodynamics in rats with chronic hyperglycemia and chronic kidney disease. A total of 30 rats were divided into six groups; Sham: control of chronic renal disease; Citrate: control of chronic hyperglycemia (CH); Nx5/6: rats with 5/6 nephrectomy; Chronic Hyperglycemia: rats receiving Streptozotocin 65 mg/kg; Nx5/6 + IC: rats Nx5/6 received 6 mL/kg of IC; CH + IC: Chronic hyperglycemia rats receiving 6 mL/kg of IC. Renal function (inulin clearance; urinary neutrophil gelatinase-associated lipocalin, NGAL) and hemodynamics (arterial blood pressure; renal blood flow; renal vascular resistance) were evaluated. Iodinated contrast significantly increased urinary NGAL and reduced inulin clearance, while the hemodynamics parameters showed changes in arterial blood pressure, renal blood flow, and renal vascular resistance in both CKD and CH groups. The results suggest that the iodinated contrast in risk factors models has important impact on renal function and hemodynamics. NGAL was confirmed to play a role of highlight in diagnosis of CI-AKI. PMID:27034930

  6. Sonophoresis Using Ultrasound Contrast Agents: Dependence on Concentration

    PubMed Central

    Park, Donghee; Song, Gillsoo; Jo, Yongjun; Won, Jongho; Son, Taeyoon; Cha, Ohrum; Kim, Jinho; Jung, Byungjo; Park, Hyunjin; Kim, Chul-Woo; Seo, Jongbum

    2016-01-01

    Sonophoresis can increase skin permeability to various drugs in transdermal drug delivery. Cavitation is recognized as the predominant mechanism of sonophoresis. Recently, a new logical approach to enhance the efficiency of transdermal drug delivery was tried. It is to utilize the engineered microbubble and its resonant frequency for increase of cavitation activity. Actively-induced cavitation with low-intensity ultrasound (less than ~1 MPa) causes disordering of the lipid bilayers and the formation of aqueous channels by stable cavitation which indicates a continuous oscillation of bubbles. Furthermore, the mutual interactions of microbubble determined by concentration of added bubble are also thought to be an important factor for activity of stable cavitation, even in different characteristics of drug. In the present study, we addressed the dependence of ultrasound contrast agent concentration using two types of drug on the efficiency of transdermal drug delivery. Two types of experiment were designed to quantitatively evaluate the efficiency of transdermal drug delivery according to ultrasound contrast agent concentration. First, an experiment of optical clearing using a tissue optical clearing agent was designed to assess the efficiency of sonophoresis with ultrasound contrast agents. Second, a Franz diffusion cell with ferulic acid was used to quantitatively determine the amount of drug delivered to the skin sample by sonophoresis with ultrasound contrast agents. The maximum enhancement ratio of sonophoresis with a concentration of 1:1,000 was approximately 3.1 times greater than that in the ultrasound group without ultrasound contrast agent and approximately 7.5 times greater than that in the control group. These results support our hypothesis that sonophoresis becomes more effective in transdermal drug delivery due to the presence of engineered bubbles, and that the efficiency of transdermal drug delivery using sonophoresis with microbubbles depends on the

  7. Sonophoresis Using Ultrasound Contrast Agents: Dependence on Concentration.

    PubMed

    Park, Donghee; Song, Gillsoo; Jo, Yongjun; Won, Jongho; Son, Taeyoon; Cha, Ohrum; Kim, Jinho; Jung, Byungjo; Park, Hyunjin; Kim, Chul-Woo; Seo, Jongbum

    2016-01-01

    Sonophoresis can increase skin permeability to various drugs in transdermal drug delivery. Cavitation is recognized as the predominant mechanism of sonophoresis. Recently, a new logical approach to enhance the efficiency of transdermal drug delivery was tried. It is to utilize the engineered microbubble and its resonant frequency for increase of cavitation activity. Actively-induced cavitation with low-intensity ultrasound (less than ~1 MPa) causes disordering of the lipid bilayers and the formation of aqueous channels by stable cavitation which indicates a continuous oscillation of bubbles. Furthermore, the mutual interactions of microbubble determined by concentration of added bubble are also thought to be an important factor for activity of stable cavitation, even in different characteristics of drug. In the present study, we addressed the dependence of ultrasound contrast agent concentration using two types of drug on the efficiency of transdermal drug delivery. Two types of experiment were designed to quantitatively evaluate the efficiency of transdermal drug delivery according to ultrasound contrast agent concentration. First, an experiment of optical clearing using a tissue optical clearing agent was designed to assess the efficiency of sonophoresis with ultrasound contrast agents. Second, a Franz diffusion cell with ferulic acid was used to quantitatively determine the amount of drug delivered to the skin sample by sonophoresis with ultrasound contrast agents. The maximum enhancement ratio of sonophoresis with a concentration of 1:1,000 was approximately 3.1 times greater than that in the ultrasound group without ultrasound contrast agent and approximately 7.5 times greater than that in the control group. These results support our hypothesis that sonophoresis becomes more effective in transdermal drug delivery due to the presence of engineered bubbles, and that the efficiency of transdermal drug delivery using sonophoresis with microbubbles depends on the

  8. Tumor Characterization with Dynamic Contrast Enhanced Magnetic Resonance Imaging and Biodegradable Macromolecular Contrast Agents in Mice

    PubMed Central

    Wu, Xueming; Feng, Yi; Jeong, Eun-Kee; Emerson, Lyska; Lu, Zheng-Rong

    2009-01-01

    Purpose To investigate the efficacy of polydisulfide-based biodegradable macromolecular contrast agents of different degradability and molecular weight for tumor characterization based on angiogenesis using dynamic contrast enhanced MRI (DCE-MRI). Methods Biodegradable macromolecular MRI contrast agents, GDCC and GDCP, with molecular weight of 20 and 70 KDa were evaluated for tumor characterization. The DCE-MRI studies were performed in nude mice bearing MDA PCa 2b and PC-3 human prostate tumor xenografts. Tumor angiogenic kinetic parameters, endothelium transfer coefficient (Ktrans) and fractional tumor plasma volume (fPV), were calculated from the DCE-MRI data using a two-compartment model. Results There was no significant difference in the fPV values between two tumor models estimated with the same agent except for GDCC-70. The Ktrans values in both tumor models decreased with increasing molecular weight of the agents. GDCC-70 showed a higher Ktrans values than GDCP-70 due to high degradability of the former in both tumor models (p < 0.05). The Ktrans values of MDA PCa 2b tumors were significantly higher than those of PC-3 tumors estimated by Gd(DTPA-BMA), GDCC-20, GDCC-70, GDCP-70, and albumin-(Gd-DTPA) (p < 0.05). Conclusions The polydisulfide based biodegradable macromolecular MRI contrast agents are promising in tumor characterization with dynamic contrast enhanced MRI. PMID:19597972

  9. Molecular Imaging and Contrast Agent Database (MICAD): Evolution and Progress

    PubMed Central

    Chopra, Arvind; Shan, Liang; Eckelman, W. C.; Leung, Kam; Latterner, Martin; Bryant, Stephen H.; Menkens, Anne

    2011-01-01

    The purpose of writing this review is to showcase the Molecular Imaging and Contrast Agent Database (MICAD; www.micad.nlm.nih.gov) to students, researchers and clinical investigators interested in the different aspects of molecular imaging. This database provides freely accessible, current, online scientific information regarding molecular imaging (MI) probes and contrast agents (CA) used for positron emission tomography, single-photon emission computed tomography, magnetic resonance imaging, x-ray/computed tomography, optical imaging and ultrasound imaging. Detailed information on >1000 agents in MICAD is provided in a chapter format and can be accessed through PubMed. Lists containing >4250 unique MI probes and CAs published in peer-reviewed journals and agents approved by the United States Food and Drug Administration (FDA) as well as a CSV file summarizing all chapters in the database can be downloaded from the MICAD homepage. Users can search for agents in MICAD on the basis of imaging modality, source of signal/contrast, agent or target category, preclinical or clinical studies, and text words. Chapters in MICAD describe the chemical characteristics (structures linked to PubChem), the in vitro and in vivo activities and other relevant information regarding an imaging agent. All references in the chapters have links to PubMed. A Supplemental Information Section in each chapter is available to share unpublished information regarding an agent. A Guest Author Program is available to facilitate rapid expansion of the database. Members of the imaging community registered with MICAD periodically receive an e-mail announcement (eAnnouncement) that lists new chapters uploaded to the database. Users of MICAD are encouraged to provide feedback, comments or suggestions for further improvement of the database by writing to the editors at: micad@nlm.nih.gov PMID:21989943

  10. Cell-Permeable MR Contrast Agents with Increased Intracellular Retention

    PubMed Central

    Endres, Paul J.; MacRenaris, Keith W.; Vogt, Stefan; Meade, Thomas J.

    2009-01-01

    Magnetic resonance imaging (MRI) is a technique used in both clinical and experimental settings to produce high resolution images of opaque organisms without ionizing radiation. Currently, MR imaging is augmented by contrast agents and the vast majority these small molecule Gd(III) chelates are confined to the extracellular regions. As a result, contrast agents are confined to vascular regions reducing their ability to provide information about cell physiology or molecular pathology. We have shown that polypeptides of arginine have the capacity to transport Gd(III) contrast agents across cell membranes. However, this transport is not unidirectional and once inside the cell the arginine-modified contrast agents efflux rapidly, decreasing the intracellular Gd(III) concentration and corresponding MR image intensity. By exploiting the inherent disulfide reducing environment of cells, thiol compounds, Gd(III)-DOTA-SS-Arg8 and Gd(III)-DTPA-SS-Arg8, are cleaved from their cell penetrating peptide transduction domains upon cell internalization. This reaction prolongs the cell-associated lifetime of the chelated Gd(III) by cleaving it from the cell transduction domain. PMID:18803414

  11. Surface Modified Gadolinium Phosphate Nanoparticles as MRI Contrast Agents

    NASA Astrophysics Data System (ADS)

    Dumont, Matthieu F.; Baligand, Celine; Knowles, Elisabeth S.; Meisel, Mark W.; Walter, Glenn A.; Talham, Daniel R.

    2012-02-01

    Nanoparticles of GdPO4H2O were synthesized in a water/oil microemulsion using IGEPAL CO-520 as surfactant resulting in 50 nm to 100 nm particles that are dispersible and stable in water. Using surface modification chemistry previously established for zirconium phosphonate surfaces,ootnotetext J. Monot et al., J. Am. Chem. Soc. 130 (2008) 6243. the particles are directly modified with 5'-phosphate terminated oligonucleotides, and the specific interaction of the divalent phosphate with Gd^3+ sites at the surface is demonstrated. The ability of the modified nanoparticles to act as MRI contrast agents was determined by performing MR relaxivity measurements at 14 T. Solutions of nanopure water, Feridex and Omniscan (FDA cleared contrast agents) in 0.25% agarose were used for comparison and control purposes. MRI data confirm that GdPO4H2O nanoparticles have relaxivities (r1,r2) comparable to commercially available contrast agents.ootnotetext H. Hifumi et al., J. Am. Chem. Soc. 128 (2006) 15090. In addition, biofunctionalization of the surface of the nanoparticles does not prevent their function as MRI contrast agents.

  12. Assessment of DNA double-strand breaks induced by intravascular iodinated contrast media following in vitro irradiation and in vivo, during paediatric cardiac catheterization.

    PubMed

    Gould, Richard; McFadden, Sonyia L; Horn, Simon; Prise, Kevin M; Doyle, Philip; Hughes, Ciara M

    2016-01-01

    Paediatric cardiac catheterizations may result in the administration of substantial amounts of iodinated contrast media and ionizing radiation. The aim of this work was to investigate the effect of iodinated contrast media in combination with in vitro and in vivo X-ray radiation on lymphocyte DNA. Six concentrations of iodine (15, 17.5, 30, 35, 45, and 52.5 mg of iodine per mL blood) represented volumes of iodinated contrast media used in the clinical setting. Blood obtained from healthy volunteers was mixed with iodinated contrast media and exposed to radiation doses commonly used in paediatric cardiac catheterizations (0 mGy, 70 mGy, 140 mGy, 250 mGy and 450 mGy). Control samples contained no iodine. For in vivo experimentation, pre and post blood samples were collected from children undergoing cardiac catheterization, receiving iodine concentrations of up to 51 mg of iodine per mL blood and radiation doses of up to 400 mGy. Fluorescence microscopy was performed to assess γH2AX-foci induction, which corresponded to the number of DNA double-strand breaks. The presence of iodine in vitro resulted in significant increases of DNA double-strand breaks beyond that induced by radiation for ≥ 17.5 mg/mL iodine to blood. The in vivo effects of contrast media on children undergoing cardiac catheterization resulted in a 19% increase in DNA double-strand breaks in children receiving an average concentration of 19 mg/mL iodine to blood. A larger investigation is required to provide further information of the potential benefit of lowering the amount of iodinated contrast media received during X-ray radiation investigations. PMID:26549792

  13. Macromolecular and Dendrimer Based Magnetic Resonance Contrast Agents

    PubMed Central

    Bumb, Ambika; Brechbiel, Martin W.; Choyke, Peter

    2010-01-01

    Magnetic resonance imaging (MRI) is a powerful imaging modality that can provide an assessment of function or molecular expression in tandem with anatomic detail. Over the last 20–25 years, a number of gadolinium based MR contrast agents have been developed to enhance signal by altering proton relaxation properties. This review explores a range of these agents from small molecule chelates, such as Gd-DTPA and Gd-DOTA, to macromolecular structures composed of albumin, polylysine, polysaccharides (dextran, inulin, starch), poly(ethylene glycol), copolymers of cystamine and cystine with GD-DTPA, and various dendritic structures based on polyamidoamine and polylysine (Gadomers). The synthesis, structure, biodistribution and targeting of dendrimer-based MR contrast agents are also discussed. PMID:20590365

  14. Paramagnetic self-assembled nanoparticles as supramolecular MRI contrast agents.

    PubMed

    Besenius, Pol; Heynens, Joeri L M; Straathof, Roel; Nieuwenhuizen, Marko M L; Bomans, Paul H H; Terreno, Enzo; Aime, Silvio; Strijkers, Gustav J; Nicolay, Klaas; Meijer, E W

    2012-01-01

    Nanometer-sized materials offer a wide range of applications in biomedical technologies, particularly imaging and diagnostics. Current scaffolds in the nanometer range predominantly make use of inorganic particles, organic polymers or natural peptide-based macromolecules. In contrast we hereby report a supramolecular approach for the preparation of self-assembled dendritic-like nanoparticles for applications as MRI contrast agents. This strategy combines the benefits from low molecular weight imaging agents with the ones of high molecular weight. Their in vitro properties are confirmed by in vivo measurements: post injection of well-defined and meta-stable nanoparticles allows for high-resolution blood-pool imaging, even at very low Gd(III) doses. These dynamic and modular imaging agents are an important addition to the young field of supramolecular medicine using well-defined nanometer-sized assemblies. PMID:22539406

  15. Evaluation of Intrarenal Oxygenation in Iodinated Contrast-Induced Acute Kidney Injury–Susceptible Rats by Blood Oxygen Level–Dependent Magnetic Resonance Imaging

    PubMed Central

    Li, Lu-Ping; Lu, Jing; Zhou, Ying; Papadopoulou, Maria V.; Franklin, Tammy; Bokhary, Ujala; Solomon, Richard; Sen, Anindya; Prasad, Pottumarthi V.

    2016-01-01

    Objectives The objectives of this study were to evaluate differences in intrarenal oxygenation as assessed by blood oxygen level–dependent (BOLD) magnetic resonance imaging in contrast-induced acute kidney injury (CIAKI)–susceptible rats when using 4 contrast media with different physicochemical properties and to demonstrate the feasibility of acquiring urinary neutrophil gelatinase–associated lipocalin (NGAL) levels as a marker of CIAKI in this model. Materials and Methods Our institutional animal care and use committee approved the study. Sixty-six Sprague-Dawley rats were divided into CIAKI-susceptible groups (received nitric oxide synthase inhibitor N-nitro-L-arginine methyl ester [10 mg/kg] and cycloxygenase inhibitor indomethacin [10mg/kg]) and control groups (received saline instead). One of the 4 iodinated contrast agents (iothalamate, iohexol, ioxaglate, or iodixanol) was then administered (1600-mg organic iodine per kilogram of body weight). Multiple blood oxygen level–dependent magnetic resonance images were acquired on a Siemens 3.0-T scanner using a multiple gradient recalled echo sequence at baseline, after N-nitro-L-arginine methyl ester (or saline), indomethacin (or saline), and iodinated contrast agent (or placebo). R2* (R2* = 1/T2*) maps were generated inline on the scanner. A mixed-effects growth curve model with first-order autoregressive variance-covariance was used to analyze the temporal data. Urinary NGAL, a marker of kidney injury (unlike serum creatinine), was measured 4 hours after contrast injection in the 2 subgroups. Results Differences in blood oxygen level–dependent magnetic resonance imaging results between the contrast media were observed in all 4 renal regions. However, the inner stripe of the outer medulla (ISOM) showed the most pronounced changes in the CIAKI-susceptible group and R2* increased significantly (P < 0.01) over time with all 4 contrast media. In the control groups, only iodixanol showed an increase in R2

  16. Novel design of multimodal MRI/NIR optical contrast agent

    NASA Astrophysics Data System (ADS)

    Guo, Kevin; Lin, Franck; Akers, Walter; Zheng, Jie; Teng, Bao; Vasalatiy, Olga; Griffiths, Gary L.; Gandjbakhche, Amir; Berezin, Mikhail Y.; Achilefu, Samuel

    2011-03-01

    We present a novel, dual modality gadolinium based MRI/near-infrared optical probe. Utilizing a fluorescent dye as a scaffold with attached Gd-chelating moiety, we demonstrated a substantial shortening of T1 relaxation time of water protons in vitro. The probe was compared to the commonly used MRI Gd-based contrast agents Magnevist® and Multihance® and showed superior contrast properties. The enhancement was due to strong albumin binding of the hydrophobic fluorophore and overall rigidification of the contrast agent. Due to the near-infrared optical properties of the probe and excellent MRI activity the proposed construct can be potentially utilized as a dual probe in multimodal MRI/NIR optical imaging.

  17. Extracardiac applications of MR blood pool contrast agent in children.

    PubMed

    Farmakis, Shannon G; Khanna, Geetika

    2014-12-01

    Magnetic resonance (MR) angiography has significantly reduced the need for diagnostic conventional angiography and is preferred over CT angiography in children because of its lack of ionizing radiation. The availability of gadofosveset trisodium (the only clinically approved blood pool MR contrast agent) has led to an increase in applications of MR for vascular imaging and an improvement in diagnostic quality of MR angiography. Gadofosveset is a gadolinium-based contrast agent that binds reversibly to albumin, resulting in increased paramagnetic effect and longer intravascular residence. This allows for high-resolution arterial and venous MR angiography, assessment of flow characteristics of vascular malformations, dynamic vascular imaging, and multi-station imaging with a single low-dose gadolinium contrast injection. The purpose of this pictorial essay is to facilitate understanding of the kinetics and safety profile of gadofosveset trisodium, discuss technical aspects of imaging, and illustrate advantages and extracardiac applications in pediatric body imaging. PMID:25408135

  18. Ultrasound Imaging Beyond the Vasculature with New Generation Contrast Agents

    PubMed Central

    Perera, Reshani H.; Hernandez, Christopher; Zhou, Haoyan; Kota, Pavan; Burke, Alan

    2015-01-01

    Current commercially available ultrasound contrast agents are gas-filled, lipid- or protein-stabilized microbubbles larger than 1 μm in diameter. Because the signal generated by these agents is highly dependent on their size, small yet highly echogenic particles have been historically difficult to produce. This has limited the molecular imaging applications of ultrasound to the blood pool. In the area of cancer imaging, microbubble applications have been constrained to imaging molecular signatures of tumor vasculature and drug delivery enabled by ultrasound-modulated bubble destruction. Recently, with the rise of sophisticated advancements in nanomedicine, ultrasound contrast agents, which are an order of magnitude smaller (100-500 nm) than their currently utilized counterparts, have been undergoing rapid development. These agents are poised to greatly expand the capabilities of ultrasound in the field of targeted cancer detection and therapy by taking advantage of the enhanced permeability and retention phenomenon of many tumors and can extravasate beyond the leaky tumor vasculature. Agent extravasation facilitates highly sensitive detection of cell surface or microenvironment biomarkers, which could advance early cancer detection. Likewise, when combined with appropriate therapeutic agents and ultrasound-mediated deployment on demand, directly at the tumor site, these nanoparticles have been shown to contribute to improved therapeutic outcomes. Ultrasound's safety profile, broad accessibility and relatively low cost make it an ideal modality for the changing face of healthcare today. Aided by the multifaceted nano-sized contrast agents and targeted theranostic moieties described herein, ultrasound can considerably broaden its reach in future applications focused on the diagnosis and staging of cancer. PMID:25580914

  19. Dual-Energy Computed Tomography Arthrography of the Shoulder Joint Using Virtual Monochromatic Spectral Imaging: Optimal Dose of Contrast Agent and Monochromatic Energy Level

    PubMed Central

    An, Chansik; Chun, Yong-Min; Kim, Sungjun; Lee, Young Han; Yun, Min Jeong; Suh, Jin-Suck

    2014-01-01

    Objective To optimize the dose of contrast agent and the level of energy for dual-energy computed tomography (DECT) arthrography of the shoulder joint and to evaluate the benefits of the optimized imaging protocol. Materials and Methods Dual-energy scans with monochromatic spectral imaging mode and conventional single energy scans were performed on a shoulder phantom with 10 concentrations from 0 to 210 mg/mL of iodinated contrast medium at intervals of 15 or 30 mg/mL. Image noise, tissue contrast, and beam hardening artifacts were assessed to determine the optimum dose of contrast agent and the level of monochromatic energy for DECT shoulder arthrography in terms of the lowest image noise and the least beam hardening artifacts while good tissue contrast was maintained. Material decomposition (MD) imaging for bone-iodine differentiation was qualitatively assessed. The optimized protocol was applied and evaluated in 23 patients. Results The optimal contrast dose and energy level were determined by the phantom study at 60 mg/mL and 72 keV, respectively. This optimized protocol for human study reduced the image noise and the beam-hardening artifacts by 35.9% and 44.5%, respectively. Bone-iodine differentiation by MD imaging was not affected by the iodine concentration or level of energy. Conclusion Dual-energy scan with monochromatic spectral imaging mode results in reduced image noise and beam hardening artifacts. PMID:25469086

  20. Redox- and Hypoxia-Responsive MRI Contrast Agents

    PubMed Central

    Do, Quyen N.; Ratnakar, James S.; Kovács, Zoltán

    2014-01-01

    The development of responsive or “smart” magnetic resonance imaging (MRI) contrast agents that can report specific biomarker or biological events has been the focus of MRI contrast agent research over the past 20 years. Among various biological hallmarks of interest, tissue redox and hypoxia are particularly important owing to their roles in disease states and metabolic consequences. Herein we review the development of redox-/hypoxia-sensitive T1 shortening and paramagnetic chemical exchange saturation transfer (PARACEST) MRI contrast agents. Traditionally, the relaxivity of redox-sensitive Gd3+-based complexes is modulated through changes in the ligand structure or molecular rotation, while PARACEST sensors exploit the sensitivity of the metal-bound water exchange rate to electronic effects of the ligand-pendant arms and alterations in the coordination geometry. Newer designs involve complexes of redox-active metal ions in which the oxidation states have different magnetic properties. The challenges of translating redox- and hypoxia-sensitive agents in vivo are also addressed. PMID:24825674

  1. Redox- and hypoxia-responsive MRI contrast agents.

    PubMed

    Do, Quyen N; Ratnakar, James S; Kovács, Zoltán; Sherry, A Dean

    2014-06-01

    The development of responsive or "smart" magnetic resonance imaging (MRI) contrast agents that can report specific biomarker or biological events has been the focus of MRI contrast agent research over the past 20 years. Among various biological hallmarks of interest, tissue redox and hypoxia are particularly important owing to their roles in disease states and metabolic consequences. Herein we review the development of redox-/hypoxia-sensitive T1 shortening and paramagnetic chemical exchange saturation transfer (PARACEST) MRI contrast agents. Traditionally, the relaxivity of redox-sensitive Gd(3+) -based complexes is modulated through changes in the ligand structure or molecular rotation, while PARACEST sensors exploit the sensitivity of the metal-bound water exchange rate to electronic effects of the ligand-pendant arms and alterations in the coordination geometry. Newer designs involve complexes of redox-active metal ions in which the oxidation states have different magnetic properties. The challenges of translating redox- and hypoxia-sensitive agents in vivo are also addressed. PMID:24825674

  2. Effects of ultrasound and ultrasound contrast agent on vascular tissue

    PubMed Central

    2012-01-01

    Background Ultrasound (US) imaging can be enhanced using gas-filled microbubble contrast agents. Strong echo signals are induced at the tissue-gas interface following microbubble collapse. Applications include assessment of ventricular function and virtual histology. Aim While ultrasound and US contrast agents are widely used, their impact on the physiological response of vascular tissue to vasoactive agents has not been investigated in detail. Methods and results In the present study, rat dorsal aortas were treated with US via a clinical imaging transducer in the presence or absence of the US contrast agent, Optison. Aortas treated with both US and Optison were unable to contract in response to phenylephrine or to relax in the presence of acetylcholine. Histology of the arteries was unremarkable. When the treated aortas were stained for endothelial markers, a distinct loss of endothelium was observed. Importantly, terminal deoxynucleotidyl transferase mediated dUTP nick-end-labeling (TUNEL) staining of treated aortas demonstrated incipient apoptosis in the endothelium. Conclusions Taken together, these ex vivo results suggest that the combination of US and Optison may alter arterial integrity and promote vascular injury; however, the in vivo interaction of Optison and ultrasound remains an open question. PMID:22805356

  3. Biodegradable Polydisulfide Dendrimer Nanoclusters as MRI Contrast Agents

    PubMed Central

    Huang, Ching-Hui; Nwe, Kido; Zaki, Ajlan Al; Brechbiel, Martin W.; Tsourkas, Andrew

    2012-01-01

    Gd-conjugated dendrimer nanoclusters (DNCs) are a promising platform for the early detection of disease; however, their clinical utility is potentially limited due to safety concerns related to nephrogenic systemic fibrosis (NSF). In this paper, biodegradable DNCs were prepared with polydisulfide linkages between the individual dendrimers to facilitate excretion. Further, DNCs were labeled with pre-metalated Gd chelates to eliminate the risk of free Gd becoming entrapped in dendrimer cavities. The biodegradable polydisulfide DNCs possessed a circulation half-life of > 1.6 h in mice and produced significant contrast enhancement in the abdominal aorta and kidneys for as long as 4 h. The DNCs were reduced in circulation as a result of thiol-disulfide exchange and the degradation products were rapidly excreted via renal filtration. These agents demonstrated effective and prolonged in vivo contrast enhancement and yet minimized Gd tissue retention. Biodegradable polydisulfide DNCs represent a promising biodegradable macromolecular MRI contrast agent for magnetic resonance angiography and can potentially be further developed into target specific MRI contrast agents. PMID:23098069

  4. Dual-frequency transducer for nonlinear contrast agent imaging.

    PubMed

    Guiroy, Axel; Novell, Anthony; Ringgaard, Erling; Lou-Moeller, Rasmus; Grégoire, Jean-Marc; Abellard, André-Pierre; Zawada, Tomasz; Bouakaz, Ayache; Levassort, Franck

    2013-12-01

    Detection of high-order nonlinear components issued from microbubbles has emerged as a sensitive method for contrast agent imaging. Nevertheless, the detection of these high-frequency components, including the third, fourth, and fifth harmonics, remains challenging because of the lack of transducer sensitivity and bandwidth. In this context, we propose a new design of imaging transducer based on a simple fabrication process for high-frequency nonlinear imaging. The transducer is composed of two elements: the outer low-frequency (LF) element was centered at 4 MHz and used in transmit mode, whereas the inner high-frequency (HF) element centered at 14 MHz was used in receive mode. The center element was pad-printed using a lead zirconate titanate (PZT) paste. The outer element was molded using a commercial PZT, and curved porous unpoled PZT was used as backing. Each piezoelectric element was characterized to determine the electromechanical performance with thickness coupling factor around 45%. After the assembly of the two transducer elements, hydrophone measurements (electroacoustic responses and radiation patterns) were carried out and demonstrated a large bandwidth (70% at -3 dB) of the HF transducer. Finally, the transducer was evaluated for contrast agent imaging using contrast agent microbubbles. The results showed that harmonic components (up to the sixth harmonic) of the microbubbles were successfully detected. Moreover, images from a flow phantom were acquired and demonstrated the potential of the transducer for high-frequency nonlinear contrast imaging. PMID:24297028

  5. Molecular nanomagnets as contrast agents for Magnetic Resonance Imaging

    NASA Astrophysics Data System (ADS)

    Rodríguez, Elisenda; Roig, Anna; Molins, Elies; Arús, Carles; Cabañas, Miquel; Quintero, María Rosa; Cerdán, Sebastián; Sanfeliu, Coral

    2003-03-01

    Magnetic resonance imaging (MRI) is a non-invasive technique used in medicine to produce high quality images of human body slices. In order to enhance the contrast between different organs or to reveal altered portions of them such necrosis or tumors, the administration of a contrast agent is highly convenient. Currently Gd-DTPA, a paramagnetic complex, is the most widely administered compound. In this context, we have assayed molecular nanomagnets as MRI contrast agents. The complex [(tacn)_6Fe_8(μ_3-O)_2(μ_2-OH)_12]Br_8·9H_2O^1(Fe8 in brief) has been evaluated and shorter relaxation times, T1 and T_2, have been obtained for Fe8 than those obtained for the commercial Gd-DTPA. No toxic effects have been observed at concentrations up to 1 mM of Fe8 in cultured cells. Phantom studies with T_1-weighted MRI at 9.4 Tesla suggest that Fe8 can have potentiality as T_1-contrast agent. ^1Wieghardt K Angew Chem Intl Ed Engl 23 1 (1984) 77

  6. Cardiac arrhythmias produced by ultrasound and contrast agents

    NASA Astrophysics Data System (ADS)

    Rota, Claudio

    Ultrasound is used widely in medicine for both diagnostic and therapeutic applications. Ultrasound contrast agents are suspensions of gas-filled microbubbles used to enhance diagnostic imaging. Microbubble contrast agents can increase the likelihood of bioeffects of ultrasound associated with acoustic cavitation. Under certain exposure conditions, the interaction of ultrasound with cardiac tissues can produce cardiac arrhythmias. The general objective of this thesis was to develop a greater understanding of ultrasound-induced premature cardiac beats. The hypothesis guiding this work was that acoustic cavitation is the physical mechanism for the production of arrhythmias with ultrasound. This hypothesis was tested through a series of experiments with mice in vivo and theoretical investigations. Results of this research supported the acoustic cavitation hypothesis. The acoustic pressure threshold for premature beats was significantly lower with microbubble contrast agents present in the blood than without. With microbubbles, the threshold for premature beats was below the current output limits of diagnostic devices. The threshold was not significantly dependent upon contrast agent type and was not influenced by contrast agent dose over three orders of magnitude. Furthermore, the dependence of the threshold on acoustic frequency was consistent with the frequency dependence of acoustic cavitation. Experimentally determined thresholds for premature beats in vivo were in excellent agreement with theoretically estimated thresholds for inertial cavitation. A passive cavitation detector (PCD) was used to measure the acoustic emissions produced by cavitating microbubbles in vivo. A direct correlation between the amplitude of the PCD and the percentage of ultrasound pulses producing a premature beat was consistent with cavitation as a mechanism for this bioeffect. Although this thesis focused on the mechanistic understanding of ultrasound-induced arrhythmias, more persistent

  7. Screening CEST contrast agents using ultrafast CEST imaging

    NASA Astrophysics Data System (ADS)

    Xu, Xiang; Yadav, Nirbhay N.; Song, Xiaolei; McMahon, Michael T.; Jerschow, Alexej; van Zijl, Peter C. M.; Xu, Jiadi

    2016-04-01

    A chemical exchange saturation transfer (CEST) experiment can be performed in an ultrafast fashion if a gradient field is applied simultaneously with the saturation pulse. This approach has been demonstrated for studying dia- and para-magnetic CEST agents, hyperpolarized Xe gas and in vivo spectroscopy. In this study we present a simple method for the simultaneous screening of multiple samples. Furthermore, by interleaving a number of saturation and readout periods within the TR, a series of images with different saturation times can be acquired, allowing for the quantification of exchange rates using the variable saturation time (QUEST) approach in a much accelerated fashion, thus enabling high throughput screening of CEST contrast agents.

  8. Towards MRI T2 contrast agents of increased efficiency

    NASA Astrophysics Data System (ADS)

    Branca, Marlène; Marciello, Marzia; Ciuculescu-Pradines, Diana; Respaud, Marc; Morales, Maria del Puerto; Serra, Raphael; Casanove, Marie-José; Amiens, Catherine

    2015-03-01

    Magnetic nanoparticles can be efficient contrast agents for T2 weighted magnetic resonance imaging (MRI) after tuning of some key parameters such as size, surface state, colloidal stability and magnetization, thus motivating the development of new synthetic pathways. In this paper we report the effects of surface coating on the efficiency of two different types of iron based nanoparticles (NPs) as MRI contrast agents. Starting from well-defined hydrophobic iron oxide nanospheres and iron nanocubes of 13 nm size, we have used three methods to increase their hydrophilicity and transfer them into water: surface ligand modification, ligand exchange or encapsulation. The NPs obtained have been characterized by dynamic light scattering and transmission electron microscopy, and the relaxivities of their stable colloidal solutions in water have been determined. Among all samples prepared, iron nanocubes coated by silica display the highest relaxivity (r2) value: 628 s-1 mM-1.

  9. Nanoshells as an optical coherence tomography contrast agent

    NASA Astrophysics Data System (ADS)

    Barton, Jennifer K.; Halas, Naomi J.; West, Jennifer L.; Drezek, Rebekah A.

    2004-07-01

    Nanoshells are a layered dielectric core/metal shell composite nanostructure with an optical resonance geometrically tunable through the visible and near infrared. Due to their small size, ability to generate a strong backscattering signal, and potential for surface modification, they may be an ideal in vivo optical coherence tomography contrast agent. We performed a pilot study to assess their capabilities. Images of a cuvette filled with dilute nanoshells, 2 μm polystyrene microspheres, or a combination were obtained. When compared to microspheres, images of the nanoshells where much brighter and attenuation of the bottom cuvette interface less. Injection of micropheres into the tail vein of mice and hamsters caused a noticeable brightening of OCT images of the dorsal skin. These pilot studies indicate that nanoshells may be an excellent OCT contrast agent; work is continuing to determine optimum nanoshell parameters and applications.

  10. Tunable Diacetylene Polymerized Shell Microbubbles as Ultrasound Contrast Agents

    PubMed Central

    Park, Yoonjee; Luce, Adam C.; Whitaker, Ragnhild D.; Amin, Bhumica; Cabodi, Mario; Nap, Rikkert J.; Szleifer, Igal; Cleveland, Robin O.; Nagy, Jon O.; Wong, Joyce Y.

    2012-01-01

    Monodisperse gas microbubbles, encapsulated with a shell of photopolymerizable diacetylene lipids and phospholipids, were produced by microfluidic flow focusing, for use as ultrasound contrast agents. The stability of the polymerized shell microbubbles against both aggregation and gas dissolution under physiological conditions was studied. Polyethylene glycol (PEG) 5000, which was attached to the diacetylene lipids, was predicted by molecular theory to provide more steric hindrance against aggregation than PEG 2000 and this was confirmed experimentally. The polymerized shell microbubbles were found to have higher shell-resistance than nonpolymerizable shell microbubbles and commercially available microbubbles (Vevo MicroMarker). The acoustic stability under 7.5 MHz ultrasound insonation was significantly greater than for the two comparison microbubbles. The acoustic stability was tunable by varying the amount of diacetylene lipid. Thus, our polymerized shell microbubbles are a promising platform for ultrasound contrast agents. PMID:22260537

  11. The in vivo relaxivity of MRI contrast agents

    NASA Astrophysics Data System (ADS)

    Shuter, Borys

    1999-11-01

    Post-contrast clinical 1H Magnetic Resonance Images have to date been interpreted with little regard for possible variations in the in-vivo properties of injected magnetic pharmaceuticals (contrast agents), particularly in their relaxivity or ability to alter tissue relaxation rates, T2-1 and T 2-1, per unit concentration. The relaxivities of contrast agents have only rarely been measured in-vivo, measurements usually being performed on excised tissues and at magnetic field strengths lower than used in clinical practice. Some researchers have simply assumed that relaxivities determined in homogeneous tissue phantoms were applicable in-vivo. In this thesis, the relaxivities of two contrast agents, Gd-DTPA and Gd-EOB-DTPA, were measured in simple tissue phantoms and in the kidney and liver of intact, but sacrificed, Wistar rats using a clinical MR scanner with a magnetic field of 1.5 Tesla. T1 and T2 were determined from sets of images acquired using a standard clinical spin-echo pulse sequence. The contrast agent concentration in tissue was assessed by radioassay of 153Gd-DTPA or 153Gd-EOB-DTPA, mixed with the normal compound prior to injection. Relaxivity was taken as the slope of a linear regression fit of relaxation rate against Gd concentration. The relaxivities of Gd-EOB-DTPA were similarly determined in normal and biliary- obstructed guinea pigs. Relaxivities in tissue differed significantly from values obtained in simple phantoms. Kidney T1 relaxivity was reduced for both compounds in normal animals. Three days or more of biliary obstruction produced further reductions in kidney T1 relaxivity of Gd-EOB-DTPA, providing strong evidence that disease affects contrast agent relaxivity. Kidney T2 relaxivity was much greater than T1 relaxivity and was also depressed by biliary obstruction. Liver T1 and T 2 relaxivites were increased above phantom values, but were not affected by the biliary obstruction. Water compartmentalisation, macromolecular binding, proton

  12. [Anaphylactic shock from an iodine contrast medium: role of the allergy check-up in one case].

    PubMed

    Halna du Fretay, X; Gaillet, G; Hoarau, C; Blanchard-Lemoine, B

    2012-12-01

    Anaphylactoid reactions to iodine contrast media are rare but serious, possibly life-threatening and calling an appropriate and urgent care. The physiopathological mechanism of these reactions remains to be fully elucidated. This reaction is still mostly called "pseudoallergic" in the literature. However, recent papers emphasise that a true allergic process is more frequent than previously expected. They also insist on the interest of running allergy tests including skin testing. We report the case of an anaphylactic shock to iodine contrast media, occurring during coronary angiography. We performed an allergy check-up and found the culprit allergen. We also evidenced a cross-reaction to another contrast media from the similar group. On the other hand, there was no reaction to contrast media of other types. With these results, another coronary angiography could be performed without any adverse event. When hypersensitivity reactions to iodine contrast media occur, it is mandatory to perform a complete allergy check-up. This will help determine the precise mechanism of the reaction and find the culprit allergen. PMID:23102513

  13. Beat frequency ultrasonic microsphere contrast agent detection system

    NASA Technical Reports Server (NTRS)

    Pretlow, III, Robert A. (Inventor); Yost, William T. (Inventor); Cantrell, Jr., John H. (Inventor)

    1997-01-01

    A system for and method of detecting and measuring concentrations of an ultrasonically-reflective microsphere contrast agent involving detecting non-linear sum and difference beat frequencies produced by the microspheres when two impinging signals with non-identical frequencies are combined by mixing. These beat frequencies can be used for a variety of applications such as detecting the presence of and measuring the flow rates of biological fluids and industrial liquids, including determining the concentration level of microspheres in the myocardium.

  14. Potential of high-Z contrast agents in clinical contrast-enhanced computed tomography

    SciTech Connect

    Nowak, Tristan; Hupfer, Martin; Brauweiler, Robert; Eisa, Fabian; Kalender, Willi A.

    2011-12-15

    Purpose: Currently, only iodine- and barium-based contrast media (CM) are used in clinical contrast-enhanced computed tomography (CE-CT). High-Z metals would produce a higher contrast at equal mass density for the x-ray spectra used in clinical CT. Using such materials might allow for significant dose reductions in CE-CT. The purpose of this study was to quantify the potential for dose reduction when using CM based on heavy metals. Methods: The contrast-to-noise ratio weighted by dose (CNRD) was determined as a function of scan protocol by means of measurements and simulations on a clinical CT scanner. For simulations, water cylinders with diameters 160, 320, 480, and 640 mm were used to cover a broad range of patient sizes. Measurements were conducted with 160 and 320 mm water-equivalent plastic cylinders. A central bore of 13 mm diameter was present in all phantoms. The tube voltage was varied from 80 to 140 kV for measurements and from 60 to 180 kV for simulations. Additional tin filtration of thicknesses 0.4, 0.8, and 1.2 mm was applied in the simulation to evaluate a range of spectral hardness. The bore was filled with a mixture of water and 10 mg/ml of pure iodine, holmium, gadolinium, ytterbium, osmium, tungsten, gold, and bismuth for the simulations and with aqueous solutions of ytterbium, tungsten, gold, and bismuth salts as well as Iopromid containing 10 mg/ml of the pure materials for the measurements. CNRDs were compared to iodine at phantom size-dependent reference voltages for all high-Z materials and the resulting dose reduction was calculated for equal contrast-to-noise ratio. Results: Dose reduction potentials strongly depended on phantom size, spectral hardness, and tube voltage. Depending on the added filtration, a dose reduction of 19%-60% could be reached at 80 kV with gadolinium for the 160 mm phantom, 52%-69% at 100 kV with holmium for the 320 mm phantom, 62%-78% with 120 kV for hafnium and the 480 mm phantom and 74%-86% with 140 kV for gold

  15. X-ray computed tomography contrast agents prepared by seeded growth of gold nanoparticles in PEGylated dendrimer

    NASA Astrophysics Data System (ADS)

    Kojima, Chie; Umeda, Yasuhito; Ogawa, Mikako; Harada, Atsushi; Magata, Yasuhiro; Kono, Kenji

    2010-06-01

    Gold nanoparticles (Au NPs) are a potential x-ray computed tomography (CT) contrast agent. A biocompatible and bioinactive surface is necessary for application of gold nanoparticle to CT imaging. Polyethylene glycol (PEG)-attached dendrimers have been used as a drug carrier with long blood circulation. In this study, the Au NPs were grown in the PEGylated dendrimer to produce a CT contrast agent. The Au NPs were grown by adding gold ions and ascorbic acid at various equivalents to the Au NP-encapsulated dendrimer solution. Both size and surface plasmon absorption of the grown Au NPs increased with adding a large number of gold ions. The x-ray attenuation of the Au NPs also increased after the seeded growth. The Au NPs grown in the PEG-attached dendrimer at the maximum under our conditions exhibited a similar CT value to a commercial iodine agent, iopamidol, in vitro. The Au NP-loaded PEGylated dendrimer and iopamidol were injected into mice and CT images were obtained at different times. The Au NP-loaded PEGylated dendrimer achieved a blood pool imaging, which was greater than a commercial iodine agent. Even though iopamidol was excreted rapidly, the PEGylated dendrimer loading the grown Au NP was accumulated in the liver.

  16. Acoustic properties of organic powders as ultrasonic contrast agents

    NASA Astrophysics Data System (ADS)

    Burov, V. A.; Loginov, S. V.; Dmitriev, K. V.

    2011-11-01

    The results of experiments on measuring attenuation and the effective acoustic nonlinear parameter of the second order are given for a suspension of cocoa-powder in water at different concentrations of the suspension. In the process of evaluating the value of the nonlinear parameter the attenuation in the suspension and generation of the second harmonic not only in the suspension but also in water are taken into account. The obtained results are evidence of the possibility of using a suspension of cocoa-powder in water as a technical substitute for ultrasonic contrast agents. The values of attenuation (up to 60 m-1 at the concentration of 1 g of the powder per 1 l of water) and the nonlinear parameter (up to 120 m-1 at the same concentration) mean that the suspension of cocoa-powder in water has smaller attenuation and the nonlinear parameter than ultrasonic contrast agents at the same concentration. However, these values for the suspension differ considerably from corresponding values for water or blood and, therefore, a suspension of cocoa-powder in water is a promising "substitute" for ultrasonic contrast agents in the case of technical testing of systems for nonlinear tomography of a blood flow, but cannot replace them in medical studies.

  17. Target-specific contrast agents for magnetic resonance microscopy

    PubMed Central

    Blackwell, Megan L.; Farrar, Christian T.; Fischl, Bruce; Rosen, Bruce R.

    2009-01-01

    High-resolution ex vivo magnetic resonance (MR) imaging can be used to delineate prominent architectonic features in the human brain, but increased contrast is required to visualize more subtle distinctions. To aid MR sensitivity to cell density and myelination, we have begun the development of target-specific paramagnetic contrast agents. This work details the first application of luxol fast blue (LFB), an optical stain for myelin, as a white matter-selective MR contrast agent for human ex vivo brain tissue. Formalin-fixed human visual cortex was imaged with an isotropic resolution between 80 and 150 μm at 4.7 and 14 T before and after en bloc staining with LFB. Longitudinal (R1) and transverse (R2) relaxation rates in LFB-stained tissue increased proportionally with myelination at both field strengths. Changes in R1 resulted in larger contrast-to-noise ratios (CNR), per unit time, on T1-weighted images between more myelinated cortical layers (IV–VI) and adjacent, superficial layers (I–III) at both field strengths. Specifically, CNR for LFB-treated samples increased by 229±13% at 4.7 T and 269±25% at 14 T when compared to controls. Also, additional cortical layers (IVca, IVd, and Va) were resolvable in 14T-MR images of LFB-treated samples but not in control samples. After imaging, samples were sliced in 40-micron sections, mounted, and photographed. Both the macroscopic and microscopic distributions of LFB were found to mimic those of traditional histological preparations. Our results suggest target-specific contrast agents will enable more detailed MR images with applications in imaging pathological ex vivo samples and constructing better MR atlases from ex vivo brains. PMID:19385012

  18. The Paramagnetic Pillared Bentonites as Digestive Tract MRI Contrast Agents

    NASA Astrophysics Data System (ADS)

    Mojović, Miloš; Daković, Marko; Omerašević, Mia; Mojović, Zorica; Banković, Predrag; Milutinović-Nikolić, Aleksandra; Jovanović, Dušan

    The increased use of imaging techniques in diagnostic studies, such as MRI, has contributed to the development of the wide range of new materials which could be successfully used as image improving agents. However, there is a lack of such substances in the area of gastrointestinal tract MRI. Many of the traditionally popular relaxation altering agents show poor results and disadvantages provoking black bowel, side effects of diarrhea and the presence of artifacts arising from clumping. Paramagnetic species seem to be potentially suitable agents for these studies, but contrast opacification has been reported and less than 60% of the gastrointestinal tract magnetic resonance scans showed improved delineation of abdominal pathologies. The new solution has been proposed as zeolites or smectite clays (hectorite and montmorillonite) enclosing of paramagnetic metal ions obtained by ion-exchange methods. However, such materials have problems of leakage of paramagnetic ions causing the appearance of the various side-effects. In this study we show that Co+2 and Dy+3 paramagnetic-pillared bentonites could be successfully used as MRI digestive tract non-leaching contrast agents, altering the longitudinal and transverse relaxation times of fluids in contact with the clay minerals.

  19. Hepatobiliary MR Imaging with Gadolinium Based Contrast Agents

    PubMed Central

    Frydrychowicz, Alex; Lubner, Meghan G.; Brown, Jeffrey J.; Merkle, Elmar M.; Nagle, Scott K.; Rofsky, Neil M.; Reeder, Scott B.

    2011-01-01

    The advent of gadolinium-based “hepatobiliary” contrast agents offers new opportunities for diagnostic MRI and has triggered a great interest for innovative imaging approaches to the liver and bile ducts. In this review article we will discuss the imaging properties of the two gadolinium-based hepatobiliary contrast agents currently available in the USA, gadobenate dimeglumine and gadoxetic acid, as well as important pharmacokinetic differences that affect their diagnostic performance. We will review potential applications, protocol optimization strategies, as well as diagnostic pitfalls. A variety of illustrative case examples will be used to demonstrate the role of these agents in detection and characterization of liver lesions as well as for imaging the biliary system. Changes in MR protocols geared towards optimizing workflow and imaging quality will also be discussed. It is our aim that the information provided in this article will facilitate the optimal utilization of these agents, and will stimulate the reader‘s pursuit of new applications for future benefit. PMID:22334493

  20. Ex vivo micro-CT imaging of murine brain models using non-ionic iodinated contrast

    NASA Astrophysics Data System (ADS)

    Salas Bautista, N.; Martínez-Dávalos, A.; Rodríguez-Villafuerte, M.; Murrieta-Rodríguez, T.; Manjarrez-Marmolejo, J.; Franco-Pérez, J.; Calvillo-Velasco, M. E.

    2014-11-01

    Preclinical investigation of brain tumors is frequently carried out by means of intracranial implantation of brain tumor xenografts or allografts, with subsequent analysis of tumor growth using conventional histopathology. However, very little has been reported on the use contrast-enhanced techniques in micro-CT imaging for the study of malignant brain tumors in small animal models. The aim of this study has been to test a protocol for ex vivo imaging of murine brain models of glioblastoma multiforme (GBM) after treatment with non-ionic iodinated solution, using an in-house developed laboratory micro-CT. We have found that the best compromise between acquisition time and image quality is obtained using a 50 kVp, 0.5 mAs, 1° angular step on a 360 degree orbit acquisition protocol, with 70 μm reconstructed voxel size using the Feldkamp algorithm. With this parameters up to 4 murine brains can be scanned in tandem in less than 15 minutes. Image segmentation and analysis of three sample brains allowed identifying tumor volumes as small as 0.4 mm3.

  1. Removal of the iodinated X-ray contrast medium diatrizoate by anaerobic transformation.

    PubMed

    Redeker, Maria; Wick, Arne; Meermann, Björn; Ternes, Thomas A

    2014-09-01

    The iodinated X-ray contrast medium diatrizoate is known to be very persistent in current wastewater treatment as well as in environmental compartments. In this study, the potential of anaerobic processes in soils, sediments, and during wastewater treatment to remove and transform diatrizoate was investigated. In anaerobic batch experiments with soil and sediment seven biologically formed transformation products (TPs) as well as the corresponding transformation pathway were identified. The TPs resulted from successive deiodinations and deacetylations. The final TP 3,5-diaminobenzoic acid (DABA) was stable under anaerobic conditions. However, DABA was further transformed under air atmosphere, indicating the potential for the mineralization of diatrizoate by combining anaerobic and aerobic conditions. With the development of a methodology using complementary liquid chromatography-electrospray ionization-tandem mass spectrometry and liquid chromatography-inductively coupled plasma-mass spectrometry techniques, all identified TPs were quantified and the mass balance could be closed without having authentic standards for four of the TPs available. The detection and quantification of diatrizoate TPs in groundwater, in technical wetlands with anaerobic zones, and in a pilot wastewater treatment plant established for anaerobic treatment highlights the transferability and up-scaling of the results attained by laboratory experiments to environmental conditions. PMID:25140788

  2. Biocompatible Nanocomplexes for Molecular Targeted MRI Contrast Agent

    NASA Astrophysics Data System (ADS)

    Chen, Zhijin; Yu, Dexin; Wang, Shaojie; Zhang, Na; Ma, Chunhong; Lu, Zaijun

    2009-07-01

    Accurate diagnosis in early stage is vital for the treatment of Hepatocellular carcinoma. The aim of this study was to investigate the potential of poly lactic acid-polyethylene glycol/gadolinium-diethylenetriamine-pentaacetic acid (PLA-PEG/Gd-DTPA) nanocomplexes using as biocompatible molecular magnetic resonance imaging (MRI) contrast agent. The PLA-PEG/Gd-DTPA nanocomplexes were obtained using self-assembly nanotechnology by incubation of PLA-PEG nanoparticles and the commercial contrast agent, Gd-DTPA. The physicochemical properties of nanocomplexes were measured by atomic force microscopy and photon correlation spectroscopy. The T1-weighted MR images of the nanocomplexes were obtained in a 3.0 T clinical MR imager. The stability study was carried out in human plasma and the distribution in vivo was investigated in rats. The mean size of the PLA-PEG/Gd-DTPA nanocomplexes was 187.9 ± 2.30 nm, and the polydispersity index was 0.108, and the zeta potential was -12.36 ± 3.58 mV. The results of MRI test confirmed that the PLA-PEG/Gd-DTPA nanocomplexes possessed the ability of MRI, and the direct correlation between the MRI imaging intensities and the nano-complex concentrations was observed ( r = 0.987). The signal intensity was still stable within 2 h after incubation of the nanocomplexes in human plasma. The nanocomplexes gave much better image contrast effects and longer stagnation time than that of commercial contrast agent in rat liver. A dose of 0.04 mmol of gadolinium per kilogram of body weight was sufficient to increase the MRI imaging intensities in rat livers by five-fold compared with the commercial Gd-DTPA. PLA-PEG/Gd-DTPA nanocomplexes could be prepared easily with small particle sizes. The nanocomplexes had high plasma stability, better image contrast effect, and liver targeting property. These results indicated that the PLA-PEG/Gd-DTPA nanocomplexes might be potential as molecular targeted imaging contrast agent.

  3. Hexameric Mn(II) Dendrimer as MRI Contrast Agent

    PubMed Central

    Zhu, Jiang; Gale, Eric M.; Atanasova, Iliyana; Rietz, Tyson A.

    2014-01-01

    A Mn(II) chelating dendrimer was prepared as a contrast agent for MRI applications. The dendrimer comprises six tyrosine-derived [Mn(EDTA)(H2O)]2− moieties coupled to a cyclotriphosphazene core. Variable temperature 17O NMR revealed a single water co-ligand per Mn(II) that undergoes fast water exchange (kex = (3.0±0.1) × 108 s−1 at 37 °C). The 37 °C per Mn(II) relaxivity ranged from 8.2 to 3.8 mM−1s−1 from 0.47 to 11.7T, and is 6-fold higher on a per molecule basis. From this field dependence a rotational correlation time was estimated as 0.45±0.02 ns. The imaging and pharmacokinetic properties of the dendrimer were compared to clinically used [Gd(DTPA)(H2O)]2− in mice at 4.7T. On first pass, the higher per ion relaxivity of the dendrimer resulted in 2-fold greater blood signal than for [Gd(DTPA)(H2O)]2−. Blood clearance was fast and elimination occurred through both the renal and hepatobiliary routes. This Mn(II) containing dendrimer represents potential alternative to Gd-based contrast agents, especially in patients with chronic kidney disease where the use of current Gd-based agents may be contraindicated. PMID:25224391

  4. Multifunctional Photosensitizer-Based Contrast Agents for Photoacoustic Imaging

    PubMed Central

    Ho, Chris Jun Hui; Balasundaram, Ghayathri; Driessen, Wouter; McLaren, Ross; Wong, Chi Lok; Dinish, U. S.; Attia, Amalina Binte Ebrahim; Ntziachristos, Vasilis; Olivo, Malini

    2014-01-01

    Photoacoustic imaging is a novel hybrid imaging modality combining the high spatial resolution of optical imaging with the high penetration depth of ultrasound imaging. Here, for the first time, we evaluate the efficacy of various photosensitizers that are widely used as photodynamic therapeutic (PDT) agents as photoacoustic contrast agents. Photoacoustic imaging of photosensitizers exhibits advantages over fluorescence imaging, which is prone to photobleaching and autofluorescence interference. In this work, we examined the photoacoustic activity of 5 photosensitizers: zinc phthalocyanine, protoporphyrin IX, 2,4-bis [4-(N,N-dibenzylamino)-2,6-dihydroxyphenyl] squaraine, chlorin e6 and methylene blue in phantoms, among which zinc phthalocyanine showed the highest photoacoustic activity. Subsequently, we evaluated its tumor localization efficiency and biodistribution at multiple time points in a murine model using photoacoustic imaging. We observed that the probe localized at the tumor within 10 minutes post injection, reaching peak accumulation around 1 hour and was cleared within 24 hours, thus, demonstrating the potential of photosensitizers as photoacoustic imaging contrast agents in vivo. This means that the known advantages of photosensitizers such as preferential tumor uptake and PDT efficacy can be combined with photoacoustic imaging capabilities to achieve longitudinal monitoring of cancer progression and therapy in vivo. PMID:24938638

  5. Nanostructured thermites based on iodine pentoxide for bio agent defeat systems.

    NASA Astrophysics Data System (ADS)

    Hobosyan, Mkhitar; Kazansky, Alexander; Martirosyan, Karen

    2011-10-01

    The risk for bioterrorist events involving the intentional airborne release of contagious agents has led to development of new approaches for bio agent defeat technologies both indoors and outdoors. Novel approaches to defeat harmful biological agents have generated a strong demand for new active materials. The preferred solutions are to neutralize the biological agents within the immediate target area by using aerosolized biocidal substances released in situ by high energetic reactions. By using nano-thermite reactions, with energy release up to 25 kJ/cc, based on I2O5/Al nanoparticles we intend to generate high quantity of vaporized iodine for spatial deposition onto harmful bacteria for their destruction. In this report, the effect of reaction product on growth and survival of Escherichia coli (E-coli) expressing GFP (Green Fluorescent Protein) was investigated. Moreover, we developed an approach to increase sensitivity of the detection. The study has shown that I2O5/Al nanosystem is extremely effective to disinfect harmful biological agents such (E-coli) bacteria in seconds.

  6. Simultaneous imaging of multiple contrast agents using full-spectrum micro-CT

    NASA Astrophysics Data System (ADS)

    Clark, D. P.; Touch, M.; Barber, W.; Badea, C. T.

    2015-03-01

    One of the major challenges for in vivo, micro-computed tomography (CT) imaging is poor soft tissue contrast. To increase contrast, exogenous contrast agents can be used as imaging probes. Combining these probes with a photon counting x-ray detector (PCXD) allows energy-sensitive CT and probe material decomposition from a series of images associated with different x-ray energies. We have implemented full-spectrum micro-CT using a PCXD and 2 keV energy sampling. We then decomposed multiple k-edge contrast materials present in an object (iodine, barium, and gadolinium) from water. Since the energy bins were quite narrow, the projection data was very noisy. This noise and further spectral distortions amplify errors in post-reconstruction material decompositions. Here, we propose and demonstrate a novel post-reconstruction denoising scheme which jointly enforces local and global gradient sparsity constraints, improving the contrast-to-noise ratio in full-spectrum micro-CT data and resultant material decompositions. We performed experiments using both calibration phantoms and ex vivo mouse data. Denoising increased the material contrast-to-noise ratio by an average of 13 times relative to filtered backprojection reconstructions. The relative decomposition error after denoising was 21%. To further improve material decomposition accuracy in future work, we also developed a model of the spectral distortions caused by PCXD imaging using known spectra from radioactive isotopes (109Cd, 133Ba). In future work, we plan to combine this model with the proposed denoising algorithm, enabling material decomposition with higher sensitivity and accuracy.

  7. Screening CEST contrast agents using ultrafast CEST imaging.

    PubMed

    Xu, Xiang; Yadav, Nirbhay N; Song, Xiaolei; McMahon, Michael T; Jerschow, Alexej; van Zijl, Peter C M; Xu, Jiadi

    2016-04-01

    A chemical exchange saturation transfer (CEST) experiment can be performed in an ultrafast fashion if a gradient field is applied simultaneously with the saturation pulse. This approach has been demonstrated for studying dia- and para-magnetic CEST agents, hyperpolarized Xe gas and in vivo spectroscopy. In this study we present a simple method for the simultaneous screening of multiple samples. Furthermore, by interleaving a number of saturation and readout periods within the TR, a series of images with different saturation times can be acquired, allowing for the quantification of exchange rates using the variable saturation time (QUEST) approach in a much accelerated fashion, thus enabling high throughput screening of CEST contrast agents. PMID:26969814

  8. What We Can Really Do with Bioresponsive MRI Contrast Agents.

    PubMed

    Angelovski, Goran

    2016-06-13

    Bioresponsive MRI contrast agents hold great promise for monitoring major physiological and pathological processes in a non-invasive manner. They are capable of altering the acquired MRI signal as a consequence of changes in their microenvironment, thus allowing real-time functional reporting in living organisms. Importantly, chemistry offers diverse solutions for the design of agents which respond to a great number of specific targets. However, the path to the successful utilization of these biomarkers in the desired functional MRI studies involves careful consideration of multiple scientific, technical, and practical issues across various research disciplines. This Minireview highlights the critical steps for planning and executing such multidisciplinary projects with an aim to substantially improve our knowledge of essential biological processes. PMID:27112329

  9. Gadolinium nanoparticles and contrast agent as radiation sensitizers.

    PubMed

    Taupin, Florence; Flaender, Mélanie; Delorme, Rachel; Brochard, Thierry; Mayol, Jean-François; Arnaud, Josiane; Perriat, Pascal; Sancey, Lucie; Lux, François; Barth, Rolf F; Carrière, Marie; Ravanat, Jean-Luc; Elleaume, Hélène

    2015-06-01

    The goal of the present study was to evaluate and compare the radiosensitizing properties of gadolinium nanoparticles (NPs) with the gadolinium contrast agent (GdCA) Magnevist(®) in order to better understand the mechanisms by which they act as radiation sensitizers. This was determined following either low energy synchrotron irradiation or high energy gamma irradiation of F98 rat glioma cells exposed to ultrasmall gadolinium NPs (GdNPs, hydrodynamic diameter of 3 nm) or GdCA. Clonogenic assays were used to quantify cell survival after irradiation in the presence of Gd using monochromatic x-rays with energies in the 25 keV-80 keV range from a synchrotron and 1.25 MeV gamma photons from a cobalt-60 source. Radiosensitization was demonstrated with both agents in combination with X-irradiation. At the same concentration (2.1 mg mL(-1)), GdNPS had a greater effect than GdCA. The maximum sensitization-enhancement ratio at 4 Gy (SER4Gy) was observed at an energy of 65 keV for both the nanoparticles and the contrast agent (2.44   ±   0.33 and 1.50   ±   0.20, for GdNPs and GdCA, respectively). At a higher energy (1.25 MeV), radiosensitization only was observed with GdNPs (1.66   ±   0.17 and 1.01   ±   0.11, for GdNPs and GdCA, respectively). The radiation dose enhancements were highly 'energy dependent' for both agents. Secondary-electron-emission generated after photoelectric events appeared to be the primary mechanism by which Gd contrast agents functioned as radiosensitizers. On the other hand, other biological mechanisms, such as alterations in the cell cycle may explain the enhanced radiosensitizing properties of GdNPs. PMID:25988839

  10. Gadolinium nanoparticles and contrast agent as radiation sensitizers

    NASA Astrophysics Data System (ADS)

    Taupin, Florence; Flaender, Mélanie; Delorme, Rachel; Brochard, Thierry; Mayol, Jean-François; Arnaud, Josiane; Perriat, Pascal; Sancey, Lucie; Lux, François; Barth, Rolf F.; Carrière, Marie; Ravanat, Jean-Luc; Elleaume, Hélène

    2015-06-01

    The goal of the present study was to evaluate and compare the radiosensitizing properties of gadolinium nanoparticles (NPs) with the gadolinium contrast agent (GdCA) Magnevist® in order to better understand the mechanisms by which they act as radiation sensitizers. This was determined following either low energy synchrotron irradiation or high energy gamma irradiation of F98 rat glioma cells exposed to ultrasmall gadolinium NPs (GdNPs, hydrodynamic diameter of 3 nm) or GdCA. Clonogenic assays were used to quantify cell survival after irradiation in the presence of Gd using monochromatic x-rays with energies in the 25 keV-80 keV range from a synchrotron and 1.25 MeV gamma photons from a cobalt-60 source. Radiosensitization was demonstrated with both agents in combination with X-irradiation. At the same concentration (2.1 mg mL-1), GdNPS had a greater effect than GdCA. The maximum sensitization-enhancement ratio at 4 Gy (SER4Gy) was observed at an energy of 65 keV for both the nanoparticles and the contrast agent (2.44   ±   0.33 and 1.50   ±   0.20, for GdNPs and GdCA, respectively). At a higher energy (1.25 MeV), radiosensitization only was observed with GdNPs (1.66   ±   0.17 and 1.01   ±   0.11, for GdNPs and GdCA, respectively). The radiation dose enhancements were highly ‘energy dependent’ for both agents. Secondary-electron-emission generated after photoelectric events appeared to be the primary mechanism by which Gd contrast agents functioned as radiosensitizers. On the other hand, other biological mechanisms, such as alterations in the cell cycle may explain the enhanced radiosensitizing properties of GdNPs.

  11. The Incidence, Classification, and Management of Acute Adverse Reactions to the Low-Osmolar Iodinated Contrast Media Isovue and Ultravist in Contrast-Enhanced Computed Tomography Scanning.

    PubMed

    Zhang, Bin; Dong, Yuhao; Liang, Long; Lian, Zhouyang; Liu, Jing; Luo, Xiaoning; Chen, Wenbo; Li, Xinyu; Liang, Changhong; Zhang, Shuixing

    2016-03-01

    Some epidemiologic surveillance studies have recorded adverse drug reactions to radiocontrast agents. We aimed to investigate the incidence and management of acute adverse reactions (AARs) to Ultravist-370 and Isovue-370 in patients who underwent contrast-enhanced computed tomography (CT) scanning.Data from 137,473 patients were analyzed. They had undergone enhanced CT scanning with intravenous injection of Ultravist-370 or Isovue-370 during the period of January 1, 2006 to December 31, 2012 in our hospital. We investigated and classified AARs according to the American College of Radiology and the Chinese Society of Radiology (CSR) guidelines for iodinated contrast media. We analyzed risk factors for AARs and compared the AARs induced by Ultravist-370 and Isovue-370.Four hundred and twenty-eight (0.31%) patients experienced AARs, which included 330 (0.24%) patients with mild AARs, 82 (0.06%) patients with moderate AARs, and 16 (0.01%) patients with severe AARs (including 3 cases of cardiac arrest and one case of death). The incidence of AARs was higher with Ultravist-370 than with Isovue-370 (0.38% vs 0.24%, P < 0.001), but only for mild AARs (0.32% vs 0.16%, P < 0.001). Analyses on risk factors indicated that female patients (n = 221, 0.43%, P < 0.001), emergency patients (n = 11, 0.51%, P < 0.001), elderly patients aged 50 to 60 years (n = 135, 0.43%, P < 0.001), and patients who underwent coronary computed tomography angiography (CTA) (n = 55, 0.51%, P < 0.001) had a higher risk of AARs. Cutaneous manifestations (50.52%)-especially rash (59.74%)-were the most frequent mild AARs. Cardiovascular manifestations accounted for most moderate and severe AARs (62.91% and 48.28%, respectively). After proper management, the symptoms and signs of 96.5% of the AARs resolved within 24 hours without sequelae.Ultravist-370 and Isovue-370 are safe for patients undergoing enhanced CT scanning. The incidence of AARs is higher with Ultravist

  12. The Incidence, Classification, and Management of Acute Adverse Reactions to the Low-Osmolar Iodinated Contrast Media Isovue and Ultravist in Contrast-Enhanced Computed Tomography Scanning

    PubMed Central

    Zhang, Bin; Dong, Yuhao; Liang, Long; Lian, Zhouyang; Liu, Jing; Luo, Xiaoning; Chen, Wenbo; Li, Xinyu; Liang, Changhong; Zhang, Shuixing

    2016-01-01

    Abstract Some epidemiologic surveillance studies have recorded adverse drug reactions to radiocontrast agents. We aimed to investigate the incidence and management of acute adverse reactions (AARs) to Ultravist-370 and Isovue-370 in patients who underwent contrast-enhanced computed tomography (CT) scanning. Data from 137,473 patients were analyzed. They had undergone enhanced CT scanning with intravenous injection of Ultravist-370 or Isovue-370 during the period of January 1, 2006 to December 31, 2012 in our hospital. We investigated and classified AARs according to the American College of Radiology and the Chinese Society of Radiology (CSR) guidelines for iodinated contrast media. We analyzed risk factors for AARs and compared the AARs induced by Ultravist-370 and Isovue-370. Four hundred and twenty-eight (0.31%) patients experienced AARs, which included 330 (0.24%) patients with mild AARs, 82 (0.06%) patients with moderate AARs, and 16 (0.01%) patients with severe AARs (including 3 cases of cardiac arrest and one case of death). The incidence of AARs was higher with Ultravist-370 than with Isovue-370 (0.38% vs 0.24%, P < 0.001), but only for mild AARs (0.32% vs 0.16%, P < 0.001). Analyses on risk factors indicated that female patients (n = 221, 0.43%, P < 0.001), emergency patients (n = 11, 0.51%, P < 0.001), elderly patients aged 50 to 60 years (n = 135, 0.43%, P < 0.001), and patients who underwent coronary computed tomography angiography (CTA) (n = 55, 0.51%, P < 0.001) had a higher risk of AARs. Cutaneous manifestations (50.52%)—especially rash (59.74%)—were the most frequent mild AARs. Cardiovascular manifestations accounted for most moderate and severe AARs (62.91% and 48.28%, respectively). After proper management, the symptoms and signs of 96.5% of the AARs resolved within 24 hours without sequelae. Ultravist-370 and Isovue-370 are safe for patients undergoing enhanced CT scanning. The incidence of AARs is

  13. Photoacoustic microscopy using Evans Blue dye as a contrast agent

    NASA Astrophysics Data System (ADS)

    Yao, Junjie; Maslov, Konstantin I.; Hu, Song; Wang, Lihong V.

    2010-02-01

    Complete and continuous imaging of microvascular networks is crucial for a wide variety of biomedical applications. Photoacoustic tomography can provide high resolution microvascular imaging using hemoglobin within red blood cells (RBC) as an endogenous contrast agent. However, intermittent RBC flow in capillaries results in discontinuous and fragmentary capillary images. To overcome this problem, we used Evans Blue (EB) dye as a contrast agent for in vivo photoacoustic imaging. EB has strong optical absorption at 610 nm and distributes uniformly in the blood stream by chemically binding to albumin. By intravenous injection of EB (6%, 200 μL), complete and continuous microvascular networks-especially capillaries-of the ears of nude mice were imaged. The diffusion of EB (3%, 100 μL) leaving the blood stream was monitored for 2 hours. At lower administration dose of EB (3%, 50 μL), the clearance of the EB-albumin complex was imaged for 10 days and quantitatively investigated using a two-compartment model.

  14. Repositioning Clofazimine as a Macrophage-Targeting Photoacoustic Contrast Agent

    PubMed Central

    Keswani, Rahul K.; Tian, Chao; Peryea, Tyler; Girish, Gandikota; Wang, Xueding; Rosania, Gus R.

    2016-01-01

    Photoacoustic Tomography (PAT) is a deep-tissue imaging modality, with potential clinical applications in the diagnosis of arthritis, cancer and other disease conditions. Here, we identified Clofazimine (CFZ), a red-pigmented dye and anti-inflammatory FDA-approved drug, as a macrophage-targeting photoacoustic (PA) imaging agent. Spectroscopic experiments revealed that CFZ and its various protonated forms yielded optimal PAT signals at wavelengths −450 to 540 nm. CFZ’s macrophage-targeting chemical and structural forms were detected with PA microscopy at a high contrast-to-noise ratio (CNR > 22 dB) as well as with macroscopic imaging using synthetic gelatin phantoms. In vivo, natural and synthetic CFZ formulations also demonstrated significant anti-inflammatory activity. Finally, the injection of CFZ was monitored via a real-time ultrasound-photoacoustic (US-PA) dual imaging system in a live animal and clinically relevant human hand model. These results demonstrate an anti-inflammatory drug repurposing strategy, while identifying a new PA contrast agent with potential applications in the diagnosis and treatment of arthritis. PMID:27000434

  15. Repositioning Clofazimine as a Macrophage-Targeting Photoacoustic Contrast Agent.

    PubMed

    Keswani, Rahul K; Tian, Chao; Peryea, Tyler; Girish, Gandikota; Wang, Xueding; Rosania, Gus R

    2016-01-01

    Photoacoustic Tomography (PAT) is a deep-tissue imaging modality, with potential clinical applications in the diagnosis of arthritis, cancer and other disease conditions. Here, we identified Clofazimine (CFZ), a red-pigmented dye and anti-inflammatory FDA-approved drug, as a macrophage-targeting photoacoustic (PA) imaging agent. Spectroscopic experiments revealed that CFZ and its various protonated forms yielded optimal PAT signals at wavelengths -450 to 540 nm. CFZ's macrophage-targeting chemical and structural forms were detected with PA microscopy at a high contrast-to-noise ratio (CNR > 22 dB) as well as with macroscopic imaging using synthetic gelatin phantoms. In vivo, natural and synthetic CFZ formulations also demonstrated significant anti-inflammatory activity. Finally, the injection of CFZ was monitored via a real-time ultrasound-photoacoustic (US-PA) dual imaging system in a live animal and clinically relevant human hand model. These results demonstrate an anti-inflammatory drug repurposing strategy, while identifying a new PA contrast agent with potential applications in the diagnosis and treatment of arthritis. PMID:27000434

  16. Modified Gadonanotubes as a promising novel MRI contrasting agent

    PubMed Central

    2013-01-01

    Background and purpose of the study Carbon nanotubes (CNTs) are emerging drug and imaging carrier systems which show significant versatility. One of the extraordinary characteristics of CNTs as Magnetic Resonance Imaging (MRI) contrasting agent is the extremely large proton relaxivities when loaded with gadolinium ion (Gdn3+) clusters. Methods In this study equated Gdn3+ clusters were loaded in the sidewall defects of oxidized multiwalled (MW) CNTs. The amount of loaded gadolinium ion into the MWCNTs was quantified by inductively coupled plasma (ICP) method. To improve water solubility and biocompatibility of the system, the complexes were functionalized using diamine-terminated oligomeric poly (ethylene glycol) via a thermal reaction method. Results Gdn3+ loaded PEGylated oxidized CNTs (Gdn3+@CNTs-PEG) is freely soluble in water and stable in phosphate buffer saline having particle size of about 200 nm. Transmission electron microscopy (TEM) images clearly showed formation of PEGylated CNTs. MRI analysis showed that the prepared solution represents 10% more signal intensity even in half concentration of Gd3+ in comparison with commerciality available contrasting agent Magnevist®. In addition hydrophilic layer of PEG at the surface of CNTs could prepare stealth nanoparticles to escape RES. Conclusion It was shown that Gdn3+@CNTs-PEG was capable to accumulate in tumors through enhanced permeability and retention effect. Moreover this system has a potential for early detection of diseases or tumors at the initial stages. PMID:23815852

  17. A sensitive multi-residue method for the determination of 35 micropollutants including pharmaceuticals, iodinated contrast media and pesticides in water.

    PubMed

    Valls-Cantenys, Carme; Scheurer, Marco; Iglesias, Mònica; Sacher, Frank; Brauch, Heinz-Jürgen; Salvadó, Victoria

    2016-09-01

    A sensitive, multi-residue method using solid-phase extraction followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed to determine a representative group of 35 analytes, including corrosion inhibitors, pesticides and pharmaceuticals such as analgesic and anti-inflammatory drugs, five iodinated contrast media, β-blockers and some of their metabolites and transformation products in water samples. Few other methods are capable of determining such a broad range of contrast media together with other analytes. We studied the parameters affecting the extraction of the target analytes, including sorbent selection and extraction conditions, their chromatographic separation (mobile phase composition and column) and detection conditions using two ionisation sources: electrospray ionisation (ESI) and atmospheric pressure chemical ionisation (APCI). In order to correct matrix effects, a total of 20 surrogate/internal standards were used. ESI was found to have better sensitivity than APCI. Recoveries ranging from 79 to 134 % for tap water and 66 to 144 % for surface water were obtained. Intra-day precision, calculated as relative standard deviation, was below 34 % for tap water and below 21 % for surface water, groundwater and effluent wastewater. Method quantification limits (MQL) were in the low ng L(-1) range, except for the contrast agents iomeprol, amidotrizoic acid and iohexol (22, 25.5 and 17.9 ng L(-1), respectively). Finally, the method was applied to the analysis of 56 real water samples as part of the validation procedure. All of the compounds were detected in at least some of the water samples analysed. Graphical Abstract Multi-residue method for the determination of micropollutants including pharmaceuticals, iodinated contrast media and pesticides in waters by LC-MS/MS. PMID:27382969

  18. Case Report: Atrial Fibrillation After Intravenous Administration of Iodinated Contrast Medium in a Patient With Hepatocellular Carcinoma.

    PubMed

    Maimone, Sergio; Filomia, Roberto; Saitta, Carlo; Raimondo, Giovanni; Squadrito, Giovanni

    2015-09-01

    We describe the case of a 73-year-old woman with liver cirrhosis and hepatocellular carcinoma (HCC) who developed 2 distinct episodes of paroxystic atrial fibrillation (AF) each of which occurred 1 to 4 hours after iodine medium contrast-enhanced computed tomography. Sinus rhythm was restored by amiodarone therapy after the first AF episode and by electrical cardioversion after the second one. A careful clinical, biochemical, and instrumental examination showed that the patient had subclinical hyperthyroidism and moderate mitral insufficiency with mild atrial enlargement.Thus, the coexistence of both subclinical disthyroidism and of cardiac anatomical alterations may have predisposed the patient to AF that in fact occurred when exogenous iodine administration triggered a hyperthyroidism status. PMID:26334896

  19. Case Report: Atrial Fibrillation After Intravenous Administration of Iodinated Contrast Medium in a Patient With Hepatocellular Carcinoma

    PubMed Central

    Maimone, Sergio; Filomia, Roberto; Saitta, Carlo; Raimondo, Giovanni; Squadrito, Giovanni

    2015-01-01

    Abstract We describe the case of a 73-year-old woman with liver cirrhosis and hepatocellular carcinoma (HCC) who developed 2 distinct episodes of paroxystic atrial fibrillation (AF) each of which occurred 1 to 4 hours after iodine medium contrast-enhanced computed tomography. Sinus rhythm was restored by amiodarone therapy after the first AF episode and by electrical cardioversion after the second one. A careful clinical, biochemical, and instrumental examination showed that the patient had subclinical hyperthyroidism and moderate mitral insufficiency with mild atrial enlargement. Thus, the coexistence of both subclinical disthyroidism and of cardiac anatomical alterations may have predisposed the patient to AF that in fact occurred when exogenous iodine administration triggered a hyperthyroidism status. PMID:26334896

  20. Characterizing Galbumin as a high molecular weight contrast agent in MRI - A novel dual contrast agent protocol

    NASA Astrophysics Data System (ADS)

    Moosvi, Firas; Reinsberg, Stefan; Baker, Jennifer

    2009-05-01

    In studying cancer and tumours, traditional biochemical methods call for analyzing frozen cross sections of tumour tissues, staining and then fluorescently imaging them at high resolution. While this method has served its purpose for decades, situations and conditions are arising that require dynamic imaging in live animals. Recent advances in the field of Biophysics have allowed researchers the ability to correlate images taken with Magnetic Resonance Imaging (MRI) to those using high- resolution fluorescent microscopy. While live imaging is possible using MRI, it is certainly not possible to reproduce much of the biologically relevant data acquired by fluorescent microscopy. In this proposal, we set the stage for the biological problem, cover some basic tumour biology then outline the basic principles of imaging with NMR. Finally, we characterize the use of a new contrast agent, Galbumin, to conduct a pilot study for a new class of animal MRI experiments.Finally, we present a novel protocol for a dual contrast agent MR protocol to extract permeability and flow information to improve characterization of drug delivery. Our over-arching goal is to use the live imaging capabilities of MR, and combine them with traditional fluorescent microscopy techniques to get a more accurate biological picture of a tumour.

  1. Ex Vivo Perfusion-Simulation Measurements of Microbubbles as a Scattering Contrast Agent for Grating-Based X-Ray Dark-Field Imaging.

    PubMed

    Velroyen, Astrid; Bech, Martin; Tapfer, Arne; Yaroshenko, Andre; Müller, Mark; Paprottka, Philipp; Ingrisch, Michael; Cyran, Clemens C; Auweter, Sigrid D; Nikolaou, Konstantin; Reiser, Maximilian F; Pfeiffer, Franz

    2015-01-01

    The investigation of dedicated contrast agents for x-ray dark-field imaging, which exploits small-angle scattering at microstructures for contrast generation, is of strong interest in analogy to the common clinical use of high-atomic number contrast media in conventional attenuation-based imaging, since dark-field imaging has proven to provide complementary information. Therefore, agents consisting of gas bubbles, as used in ultrasound imaging for example, are of particular interest. In this work, we investigate an experimental contrast agent based on microbubbles consisting of a polyvinyl-alcohol shell with an iron oxide coating, which was originally developed for multimodal imaging and drug delivery. Its performance as a possible contrast medium for small-animal angiography was examined using a mouse carcass to realistically consider attenuating and scattering background signal. Subtraction images of dark field, phase contrast and attenuation were acquired for a concentration series of 100%, 10% and 1.3% to mimic different stages of dilution in the contrast agent in the blood vessel system. The images were compared to the gold-standard iodine-based contrast agent Solutrast, showing a good contrast improvement by microbubbles in dark-field imaging. This study proves the feasibility of microbubble-based dark-field contrast-enhancement in presence of scattering and attenuating mouse body structures like bone and fur. Therefore, it suggests a strong potential of the use of polymer-based microbubbles for small-animal dark-field angiography. PMID:26134130

  2. Ex Vivo Perfusion-Simulation Measurements of Microbubbles as a Scattering Contrast Agent for Grating-Based X-Ray Dark-Field Imaging

    PubMed Central

    Velroyen, Astrid; Bech, Martin; Tapfer, Arne; Yaroshenko, Andre; Müller, Mark; Paprottka, Philipp; Ingrisch, Michael; Cyran, Clemens C.; Auweter, Sigrid D.; Nikolaou, Konstantin; Reiser, Maximilian F.; Pfeiffer, Franz

    2015-01-01

    The investigation of dedicated contrast agents for x-ray dark-field imaging, which exploits small-angle scattering at microstructures for contrast generation, is of strong interest in analogy to the common clinical use of high-atomic number contrast media in conventional attenuation-based imaging, since dark-field imaging has proven to provide complementary information. Therefore, agents consisting of gas bubbles, as used in ultrasound imaging for example, are of particular interest. In this work, we investigate an experimental contrast agent based on microbubbles consisting of a polyvinyl-alcohol shell with an iron oxide coating, which was originally developed for multimodal imaging and drug delivery. Its performance as a possible contrast medium for small-animal angiography was examined using a mouse carcass to realistically consider attenuating and scattering background signal. Subtraction images of dark field, phase contrast and attenuation were acquired for a concentration series of 100%, 10% and 1.3% to mimic different stages of dilution in the contrast agent in the blood vessel system. The images were compared to the gold-standard iodine-based contrast agent Solutrast, showing a good contrast improvement by microbubbles in dark-field imaging. This study proves the feasibility of microbubble-based dark-field contrast-enhancement in presence of scattering and attenuating mouse body structures like bone and fur. Therefore, it suggests a strong potential of the use of polymer-based microbubbles for small-animal dark-field angiography. PMID:26134130

  3. Cellulose nanoparticles: photoacoustic contrast agents that biodegrade to simple sugars

    NASA Astrophysics Data System (ADS)

    Jokerst, Jesse V.; Bohndiek, Sarah E.; Gambhir, Sanjiv S.

    2014-03-01

    In photoacoustic imaging, nanoparticle contrast agents offer strong signal intensity and long-term stability, but are limited by poor biodistribution and clearance profiles. Conversely, small molecules offer renal clearance, but relatively low photoacoustic signal. Here we describe a cellulose-based nanoparticle with photoacoustic signal superior to gold nanorods, but that undergoes enzymatic cleavage into constituent glucose molecules for renal clearance. Cellulose nanoparticles (CNPs) were synthesized through acidic cleavage of cellulose linters and purified with centrifugation. TEM indicated that the nanoparticles were 132 +/- 46 nm; the polydispersity index was 0.138. Ex vivo characterization showed a photoacoustic limit of detection of 0.02 mg/mL CNPs, and the photoacoustic signal of CNPs was 1.5- to 3.0-fold higher than gold nanorods (also at 700 nm resonance) on a particle-to-particle basis. Cell toxicity assays suggested that overnight doses below 0.31 mg/mL CNPs produced no significant (p>0.05) impact on cell metabolism. Intravenous doses up to 0.24 mg were tolerated well in nude mice. Subcutaneous and orthotopic tumor xenografts of the OV2008 ovarian cancer cell line were then created in nude mice. Data was collected with a Nexus128 scanner from Endra LifeSciences. Spectral data used a LAZR system from Visualsonics both at 700 nm excitation. We injected CNPs (0.024 mg, 0.048 mg, and 0.80 mg) via tail vein and showed that the tumor photoacoustic signal reached maximum increase between 10 and 20 minutes. All injected concentrations were statistically (p<0.05) elevated relative to the control group with n=3 mice in each group, and dose and signal had a linear relationship at R2>0.96 suggesting quantitative signal. CNP biodegradation was demonstrated ex vivo with a glucose assay. CNPs in the presence of cellulase were reduced to free glucose in under than four hours. The glucose concentration before addition of cellulase was not detectable, but increased to

  4. Hafnia (HfO2) nanoparticles as an X-ray contrast agent and mid-infrared biosensor.

    PubMed

    McGinnity, Tracie L; Dominguez, Owen; Curtis, Tyler E; Nallathamby, Prakash D; Hoffman, Anthony J; Roeder, Ryan K

    2016-07-14

    The interaction of hafnium oxide (HfO2) nanoparticles (NPs) with X-ray and mid-infrared radiation was investigated to assess the potential as a multifunctional diagnostic probe for X-ray computed tomography (CT) and/or mid-infrared biosensing. HfO2 NPs of controlled size were prepared by a sol-gel process and surface functionalized with polyvinylpyrrolidone, resulting in relatively spherical and monodispersed NPs with a tunable mean diameter in the range of ∼7-31 nm. The X-ray attenuation of HfO2 NPs was measured over 0.5-50 mM concentration and compared with Au NPs and iodine, which are the most prominent X-ray contrast agents currently used in research and clinical diagnostic imaging, respectively. At clinical CT tube potentials >80 kVp, HfO2 NPs exhibited superior or similar X-ray contrast compared to Au NPs, while both exhibited significantly greater X-ray contrast compared to iodine, due to the favorable location of the k-shell absorption edge for hafnium and gold. Moreover, energy-dependent differences in X-ray attenuation enabled simultaneous quantitative molecular imaging of each agent using photon-counting spectral (multi-energy) CT. HfO2 NPs also exhibited a strong mid-infrared absorption in the Reststrahlen band from ∼250-800 cm(-1) and negative permittivity below 695 cm(-1), which can enable development of mid-infrared biosensors and contrast agents, leveraging surface enhanced mid-infrared and/or phonon polariton absorption. PMID:27364973

  5. Hafnia (HfO2) nanoparticles as an X-ray contrast agent and mid-infrared biosensor

    NASA Astrophysics Data System (ADS)

    McGinnity, Tracie L.; Dominguez, Owen; Curtis, Tyler E.; Nallathamby, Prakash D.; Hoffman, Anthony J.; Roeder, Ryan K.

    2016-07-01

    The interaction of hafnium oxide (HfO2) nanoparticles (NPs) with X-ray and mid-infrared radiation was investigated to assess the potential as a multifunctional diagnostic probe for X-ray computed tomography (CT) and/or mid-infrared biosensing. HfO2 NPs of controlled size were prepared by a sol-gel process and surface functionalized with polyvinylpyrrolidone, resulting in relatively spherical and monodispersed NPs with a tunable mean diameter in the range of ~7-31 nm. The X-ray attenuation of HfO2 NPs was measured over 0.5-50 mM concentration and compared with Au NPs and iodine, which are the most prominent X-ray contrast agents currently used in research and clinical diagnostic imaging, respectively. At clinical CT tube potentials >80 kVp, HfO2 NPs exhibited superior or similar X-ray contrast compared to Au NPs, while both exhibited significantly greater X-ray contrast compared to iodine, due to the favorable location of the k-shell absorption edge for hafnium and gold. Moreover, energy-dependent differences in X-ray attenuation enabled simultaneous quantitative molecular imaging of each agent using photon-counting spectral (multi-energy) CT. HfO2 NPs also exhibited a strong mid-infrared absorption in the Reststrahlen band from ~250-800 cm-1 and negative permittivity below 695 cm-1, which can enable development of mid-infrared biosensors and contrast agents, leveraging surface enhanced mid-infrared and/or phonon polariton absorption.

  6. Biological in situ characterization of polymeric microbubble contrast agents.

    PubMed

    Wan, Sha; Egri, Gabriella; Oddo, Letizia; Cerroni, Barbara; Dähne, Lars; Paradossi, Gaio; Salvati, Anna; Lynch, Iseult; Dawson, Kenneth A; Monopoli, Marco P

    2016-06-01

    Polymeric microbubbles (MBs) are gas filled particles composed of a thin stabilized polymer shell that have been recently developed as valid contrast agents for the combined use of ultrasonography (US), magnetic resonance imaging (MRI) and single photon emission computer tomography (SPECT) imaging. Due to their buoyancy, the commonly available approaches to study their behaviour in complex media are not easily applicable and their use in modern medicine requires such behaviour to be fully elucidated. Here we have used for the first time flow cytometry as a new high throughput approach that allows characterisation of the MB dispersion, prior to and after exposure in different biological media and we have additionally developed a method that allows characterisation of the strongly bound proteins adsorbed on the MBs, to fully predict their biological behaviour in biological milieu. PMID:26993210

  7. Superparamagnetic FePt nanoparticles as excellent MRI contrast agents

    NASA Astrophysics Data System (ADS)

    Maenosono, Shinya; Suzuki, Toshimasa; Saita, Soichiro

    Chemically disordered face-centered cubic (fcc) FePt nanoparticles (NPs) with a mean diameter of 9 nm were synthesized via pyrolysis of iron(III) ethoxide and platinum(II) acetylacetonate. The surface ligands of these NPs were then exchanged from oleic acid to tetramethylammonium hydroxide (TMAOH) to measure the longitudinal ( T1) and transverse ( T2) proton relaxation times of aqueous dispersion of FePt NPs. Magnetic resonance relaxometry reveals that TMAOH-capped FePt NPs have a higher T2-shortening effect than conventional superparamagnetic iron oxide NPs, indicating that fcc-phase FePt NPs might be superior negative contrast agents for magnetic resonance imaging.

  8. Biodistribution of gadolinium-based contrast agents, including gadolinium deposition

    PubMed Central

    Aime, Silvio; Caravan, Peter

    2010-01-01

    The biodistribution of approved gadolinium (Gd) based contrast agents (GBCA) is reviewed. After intravenous injection GBCA distribute in the blood and the extracellular space and transiently through the excretory organs. Preclinical animal studies and the available clinical literature indicate that all these compounds are excreted intact. Elimination tends to be rapid and for the most part, complete. In renally insufficient patients the plasma elimination half-life increases substantially from hours to days depending on renal function. In patients with impaired renal function and nephrogenic systemic fibrosis (NSF), the agents gadodiamide, gadoversetamide, and gadopentetate dimeglumine have been shown to result in Gd deposition in the skin and internal organs. In these cases, it is likely that the Gd is no longer present as the GBCA, but this has still not been definitively shown. In preclinical models very small amounts of Gd are retained in the bone and liver, and the amount retained correlates with the kinetic and thermodynamic stability of the GBCA with respect to Gd release in vitro. The pattern of residual Gd deposition in NSF subjects may be different than that observed in preclinical rodent models. GBCA are designed to be used via intravenous administration. Altering the route of administration and/or the formulation of the GBCA can dramatically alter the biodistribution of the GBCA and can increase the likelihood of Gd deposition. PMID:19938038

  9. Mechanically Tunable Hollow Silica Ultrathin Nanoshells for Ultrasound Contrast Agents

    PubMed Central

    Liberman, A.; Wang, J.; Lu, N.; Viveros, R.D.; Allen, C. A.; Mattrey, R.F.; Blair, S.L.; Trogler, W.C.; Kim, M. J.; Kummel, A.C.

    2015-01-01

    Perfluoropentane (PFP) gas filled biodegradable iron-doped silica nanoshells have been demonstrated as long-lived ultrasound contrast agents. Nanoshells are synthesized by a sol-gel process with tetramethyl orthosilicate (TMOS) and iron ethoxide. Substituting a fraction of the TMOS with R-substituted trialkoxysilanes produces ultrathin nanoshells with varying shell thicknesses and morphologies composed of fused nanoflakes. The ultrathin nanoshells had continuous ultrasound Doppler imaging lifetimes exceeding 3 hours, were twice as bright using contrast specific imaging, and had decreased pressure thresholds compared to control nanoshells synthesized with just TMOS. Transmission electron microscopy (TEM) showed that the R-group substituted trialkoxysilanes could reduce the mechanically critical nanoshell layer to 1.4 nm. These ultrathin nanoshells have the mechanical behavior of weakly linked nanoflakes but the chemical stability of silica. The synthesis can be adapted for general fabrication of three-dimensional nanostructures composed of nanoflakes, which have thicknesses from 1.4–3.8 nm and diameters from 2–23 nm. PMID:26955300

  10. Successful balloon pulmonary angioplasty with gadolinium contrast media for a patient with chronic thromboembolic pulmonary hypertension and iodine allergy

    PubMed Central

    Nakamura, Tomohisa; Ogo, Takeshi; Tsuji, Akihiro; Fukui, Shigefumi; Fukuda, Tetsuya; Tahara, Nobuhiro; Fukumoto, Yoshihiro; Yasuda, Satoshi; Ogawa, Hisao; Nakanishi, Norifumi

    2016-01-01

    A 28-year-old male was referred to our hospital with dyspnea. He was diagnosed as having chronic thromboembolic pulmonary hypertension, and a pulmonary endarterectomy (PEA) was performed. However, exertional dyspnea remained because of residual pulmonary hypertension; therefore, the patient was re-admitted to our hospital 1 year after PEA. We performed computed tomography and pulmonary angiography and found web and band lesions in the distal pulmonary artery with a high pulmonary artery pressure. Although further management was complicated because the patient had an anaphylactic shock to iodine-based contrast media, we eventually completed five sessions of balloon pulmonary angioplasty (BPA) using gadolinium contrast medium. His symptoms and hemodynamics dramatically improved after a series of BPA. After 15 months, mean pulmonary arterial pressure reduced from 67 mmHg to 20 mmHg, and subjective symptoms improved from stage Ⅳ to I as per the WHO classification system. BPA is a potential procedure for residual pulmonary hypertension after PEA and could be safely performed using gadolinium contrast medium for patients with iodine allergy. PMID:27141436

  11. Contrast Induced Nephropathy with Intravenous Iodinated Contrast Media in Routine Diagnostic Imaging: An Initial Experience in a Tertiary Care Hospital

    PubMed Central

    Bhatt, Shuchi; Rajpal, Nipun; Rathi, Vineeta; Avasthi, Rajneesh

    2016-01-01

    Background. Contrast induced nephropathy (CIN) is common cause of hospital acquired renal failure, defined as iatrogenic deterioration of renal function following intravascular contrast administration in the absence of another nephrotoxic event. Objectives. Objectives were to calculate incidence of CIN with routine IV contrast usage and to identify its risk factors. Materials and Methods. Study was conducted on 250 patients (having eGFR ≥ 45 mL/min/1.73 m2) receiving intravenous contrast. Various clinical risk factors and details of contrast media were recorded. Patients showing 25% increase in postprocedural serum creatinine value or an absolute increase of 0.5 mg/dL (44.2 mmol/L) were diagnosed as having CIN. Results and Conclusions. Postprocedural serum creatinine showed significant increase from baseline levels. 25 patients (10%) developed CIN. CIN was transient in 21 (84%) patients developing CIN. One patient (4%) developed renal failure and another died due to unknown cause. Dehydration, preexisting renal disease, cardiac failure, previous contrast administration, and volume of contrast had significant correlation with development of CIN (p < 0.05); whereas demographic variables, baseline serum creatinine/eGFR, previous renal surgery, diabetes mellitus, hypertension, nephrotoxic drug intake, abnormal routine hematology, and contrast characteristics had no correlation with CIN. CIN is a matter of concern even in routine imaging requiring intravenous contrast media, in our set-up. PMID:27069686

  12. Comparison of iodinated trihalomethanes formation during aqueous chlor(am)ination of different iodinated X-ray contrast media compounds in the presence of natural organic matter.

    PubMed

    Ye, Tao; Xu, Bin; Wang, Zhen; Zhang, Tian-Yang; Hu, Chen-Yan; Lin, Lin; Xia, Sheng-Ji; Gao, Nai-Yun

    2014-12-01

    Iodinated trihalomethanes (I-THMs) formation during chlorination and chloramination of five iodinated X-ray contrast media (ICM) compounds (iopamidol, iopromide, iodixanol, histodenz, and diatrizoate) in the presence of natural organic matter (NOM) was evaluated and compared. Chlorination and chloramination of ICM in the absence of NOM yielded only a trace amount of I-THMs, while levels of I-THMs were enhanced substantially in raw water samples. With the presence of NOM, the order with respect to the maximum yield of I-THMs observed during chlorination was iopamidol > histodenz > iodixanol > diatrizoate > iopromide. During chloramination, I-THM formation was enhanced for hisodenz, iodixanol, diatrizoate, and iopromide. The order with respect to the maximum yield of I-THMs observed during chloramination was iopamidol > diatrizoate > iodixanol > histodenz > iopromide. With the exception of iopamidol, I-THM formation was favored at relatively low chlorine doses (≤100 μM) during ICM chlorination, and significant suppression was observed with high chlorine doses applied (>100 μM). However, during chloramination, increasing monochloramine dose monotonously increased the yield of I-THMs for the five ICM. During chlorination of iodixanol, histodenz, and diatrizoate, the yields of I-THMs exhibited three distinct trends as the pH increased from 5 to 9, while peak I-THM formation was found at circumneutral pH for chloramination. Increasing bromide concentration not only considerably enhanced the yield of I-THMs but also shifted the I-THMs towards bromine-containing ones and increased the formation of higher bromine-incorporated species (e.g., CHBrClI and CHBr2I), especially in chloramination. These results are of particular interest to understand I-THM formation mechanisms during chlorination and chloramination of waters containing ICM. PMID:25240119

  13. Optical contrast agents to visualize molecular expression in breast cancer

    NASA Astrophysics Data System (ADS)

    Langsner, Robert James

    Breast cancer is the second leading cause of death of women in the United States. Improvements in screening technology have increased the breast cancer incidence rate, as smaller lesions are being detected. Due to the small size of lesions, patients can choose to receive breast conservation therapy (BCT) rather than a modified radical mastectomy. Even though the breast retains cosmesis after BCT, there is an increased risk of the patient having residual microscopic disease, known as positive margins. Patients with positive margins receive increased radiation and have an increased chance of second surgery. Pathology with hematoxylin and eosin (H&E) remains the gold standard for diagnosing margin status in patients. Intraoperative pathology has been shown to reduce the rate of positive margins in BCT. However, a minority of surgery centers have intraoperative pathology centers, limiting the number of patients that receive this standard of care. The expression profiles of surface receptors such as ErbB2 (HER2-positive) and epidermal growth factor receptor (EGFR) provide information about the aggressiveness of a particular tumor. Recent research has shown that there was elevated EGFR expression in patients with a local recurrence even though the biopsies were assessed to be disease free using standard H&E. If the physicians had known the molecular expression of these biopsies, a different treatment regimen or excision of more tissue might have prevented the recurrence. This thesis investigates targeted molecular contrast agents that enhance the visualization of molecular markers such as glucose transporters (GLUTs) and growth factor receptors in tissue specimens. First, application of 2-NBDG, a fluorescent deoxyglucose, enhances signal in cancerous tissue with a 20-minute incubation. Then, antibody functionalized silica-gold nanoshells enhance the visualization of ErbB2 overexpression in specimens with a 5-minute incubation. To image these contrast agents in cancerous

  14. Synthesis, Characterization, In Vitro Phantom Imaging, and Cytotoxicity of A Novel Graphene-Based Multimodal Magnetic Resonance Imaging - X-Ray Computed Tomography Contrast Agent.

    PubMed

    Lalwani, Gaurav; Sundararaj, Joe Livingston; Schaefer, Kenneth; Button, Terry; Sitharaman, Balaji

    2014-06-14

    Graphene nanoplatelets (GNPs), synthesized using potassium permanganate-based oxidation and exfoliation followed by reduction with hydroiodic acid (rGNP-HI), have intercalated manganese ions within the graphene sheets, and upon functionalization with iodine, show excellent potential as biomodal contrast agents for magnetic resonance imaging (MRI) and computed tomography (CT). Structural characterization of rGNP-HI nanoparticles with low- and high-resolution transmission electron microscope (TEM) showed disc-shaped nanoparticles (average diameter, 200 nm, average thickness, 3 nm). Energy dispersive X-ray spectroscopy (EDX) analysis confirmed the presence of intercalated manganese. Raman spectroscopy and X-ray diffraction (XRD) analysis of rGNP-HI confirmed the reduction of oxidized GNPs (O-GNPs), absence of molecular and physically adsorbed iodine, and the functionalization of graphene with iodine as polyiodide complexes (I3 (-) and I5 (-)). Manganese and iodine content were quantified as 5.1 ± 0.5 and 10.54 ± 0.87 wt% by inductively-coupled plasma optical emission spectroscopy and ion-selective electrode measurements, respectively. In vitro cytotoxicity analysis, using absorbance (LDH assay) and fluorescence (calcein AM) based assays, performed on NIH3T3 mouse fibroblasts and A498 human kidney epithelial cells, showed CD50 values of rGNP-HI between 179-301 µg/ml, depending on the cell line and the cytotoxicity assay. CT and MRI phantom imaging of rGNP-HI showed high CT (approximately 3200% greater than HI at equimolar iodine concentration) and MRI (approximately 59% greater than equimolar Mn(2+) solution) contrast. These results open avenues for further in vivo safety and efficacy studies towards the development of carbon nanostructure-based multimodal MRI-CT contrast agents. PMID:24999431

  15. Synthesis, Characterization, In Vitro Phantom Imaging, and Cytotoxicity of A Novel Graphene-Based Multimodal Magnetic Resonance Imaging - X-Ray Computed Tomography Contrast Agent

    PubMed Central

    Lalwani, Gaurav; Sundararaj, Joe Livingston; Schaefer, Kenneth; Button, Terry; Sitharaman, Balaji

    2014-01-01

    Graphene nanoplatelets (GNPs), synthesized using potassium permanganate-based oxidation and exfoliation followed by reduction with hydroiodic acid (rGNP-HI), have intercalated manganese ions within the graphene sheets, and upon functionalization with iodine, show excellent potential as biomodal contrast agents for magnetic resonance imaging (MRI) and computed tomography (CT). Structural characterization of rGNP-HI nanoparticles with low- and high-resolution transmission electron microscope (TEM) showed disc-shaped nanoparticles (average diameter, 200 nm, average thickness, 3 nm). Energy dispersive X-ray spectroscopy (EDX) analysis confirmed the presence of intercalated manganese. Raman spectroscopy and X-ray diffraction (XRD) analysis of rGNP-HI confirmed the reduction of oxidized GNPs (O-GNPs), absence of molecular and physically adsorbed iodine, and the functionalization of graphene with iodine as polyiodide complexes (I3− and I5−). Manganese and iodine content were quantified as 5.1 ± 0.5 and 10.54 ± 0.87 wt% by inductively-coupled plasma optical emission spectroscopy and ion-selective electrode measurements, respectively. In vitro cytotoxicity analysis, using absorbance (LDH assay) and fluorescence (calcein AM) based assays, performed on NIH3T3 mouse fibroblasts and A498 human kidney epithelial cells, showed CD50 values of rGNP-HI between 179-301 µg/ml, depending on the cell line and the cytotoxicity assay. CT and MRI phantom imaging of rGNP-HI showed high CT (approximately 3200% greater than HI at equimolar iodine concentration) and MRI (approximately 59% greater than equimolar Mn2+ solution) contrast. These results open avenues for further in vivo safety and efficacy studies towards the development of carbon nanostructure-based multimodal MRI-CT contrast agents. PMID:24999431

  16. Section 6—Mechanical Bioeffects in the Presence of Gas-Carrier Ultrasound Contrast Agents

    PubMed Central

    2007-01-01

    This review addresses the issue of mechanical ultrasound-induced bioeffects in the presence of gas carrier contrast agents (GCAs). Here, the term “contrast agent” refers to those agents that provide ultrasound contrast by being composed of microbubbles, encapsulated or not, containing one or more gases. Provided in this section are summaries on how contrast agents work, some of their current uses, and the potential for bio-effects associated with their presence in an ultrasonic field. PMID:10680618

  17. Ultrasound Induced Fluorescence of Nanoscale Liposome Contrast Agents

    PubMed Central

    Zhang, Qimei; Morgan, Stephen P.; O’Shea, Paul; Mather, Melissa L.

    2016-01-01

    A new imaging contrast agent is reported that provides an increased fluorescent signal upon application of ultrasound (US). Liposomes containing lipids labelled with pyrene were optically excited and the excimer fluorescence emission intensity was detected in the absence and presence of an ultrasound field using an acousto-fluorescence setup. The acousto-fluorescence dynamics of liposomes containing lipids with pyrene labelled on the fatty acid tail group (PyPC) and the head group (PyPE) were compared. An increase in excimer emission intensity following exposure to US was observed for both cases studied. The increased intensity and time constants were found to be different for the PyPC and PyPE systems, and dependent on the applied US pressure and exposure time. The greatest change in fluorescence intensity (130%) and smallest rise time constant (0.33 s) are achieved through the use of PyPC labelled liposomes. The mechanism underlying the observed increase of the excimer emission intensity in PyPC labelled liposomes is proposed to arise from the “wagging” of acyl chains which involves fast response and requires lower US pressure. This is accompanied by increased lipid lateral diffusivity at higher ultrasound pressures, a mechanism that is also active in the PyPE labelled liposomes. PMID:27467748

  18. BROADBAND ATTENUATION MEASUREMENTS OF PHOSPHOLIPID-SHELLED ULTRASOUND CONTRAST AGENTS

    PubMed Central

    Raymond, Jason L.; Haworth, Kevin J.; Bader, Kenneth B.; Radhakrishnan, Kirthi; Griffin, Joseph K.; Huang, Shao-Ling; McPherson, David D.; Holland, Christy K.

    2014-01-01

    The aim of this study was to characterize the frequency-dependent acoustic attenuation of three phospholipid-shelled ultrasound contrast agents (UCAs): Definity, MicroMarker and echogenic liposomes. A broadband through-transmission technique allowed for measurement over 2 to 25 MHz with a single pair of transducers. Viscoelastic shell parameters of the UCAs were estimated using a linearized model developed by N. de Jong, L. Hoff, T. Skotland and N. Bom (Ultrasonics 1992; 30:95–103). The effect of diluent on the attenuation of these UCA suspensions was evaluated by performing attenuation measurements in 0.5% (w/v) bovine serum albumin and whole blood. Changes in attenuation and shell parameters of the UCAs were investigated at room temperature (25°C) and physiologic temperature (37°C). The attenuation of the UCAs diluted in 0.5% (w/v) bovine serum albumin was found to be identical to the attenuation of UCAs in whole blood. For each UCA, attenuation was higher at 37°C than at 25°C, underscoring the importance of conducting characterization studies at physiologic temperature. Echogenic liposomes exhibited a larger increase in attenuation at 37°C versus 25°C than either Definity or MicroMarker. PMID:24262056

  19. Proposal of a skin tests based approach for the prevention of recurrent hypersensitivity reactions to iodinated contrast media.

    PubMed

    Della-Torre, E; Berti, A; Yacoub, M R; Guglielmi, B; Tombetti, E; Sabbadini, M G; Voltolini, S; Colombo, G

    2015-05-01

    The purpose of the present work is to evaluate the efficacy of an approach that combines clinical history, skin tests results, and premedication, in preventing recurrent hypersensitivity reactions to iodinated contrast media (ICM). Skin Prick tests, Intradermal tests, and Patch tests were performed in 36 patients with a previous reaction to ICM. All patients underwent a second contrast enhanced radiological procedure with an alternative ICM selected on the basis of the proposed approach. After alternative ICM re-injection, only one patient presented a mild NIR. The proposed algorithm, validated in clinical settings where repeated radiological exams are needed, offers a safe and practical approach for protecting patients from recurrent hypersensitivity reactions to ICM. PMID:25951145

  20. Complex interfaces in "phase-change" contrast agents.

    PubMed

    Capece, Sabrina; Domenici, Fabio; Brasili, Francesco; Oddo, Letizia; Cerroni, Barbara; Bedini, Angelico; Bordi, Federico; Chiessi, Ester; Paradossi, Gaio

    2016-03-28

    In this paper we report on the study of the interface of hybrid shell droplets encapsulating decafluoropentane (DFP), which exhibit interesting potentialities for ultrasound (US) imaging. The fabrication of the droplets is based on the deposition of a dextran methacrylate layer onto the surface of surfactants. The droplets have been stabilized against coalescence by UV curing, introducing crosslinks in the polymer layer and transforming the shell into an elastomeric membrane with a thickness of about 300 nm with viscoelastic behaviour. US irradiation induces the evaporation of the DFP core of the droplets transforming the particles into microbubbles (MBs). The presence of a robust crosslinked polymer shell introduces an unusual stability of the droplets also during the core phase transition and allows the recovery of the initial droplet state after a few minutes from switching off US. The interfacial tension of the droplets has been investigated by two approaches, the pendant drop method and an indirect method, based on the determination of the liquid ↔ gas transition point of DFP confined in the droplet core. The re-condensation process has been followed by capturing images of single MBs by confocal microscopy. The time evolution of MB relaxation to droplets was analysed in terms of a modified Church model to account for the structural complexity of the MB shell, i.e. a crosslinked polymer layer over a layer of surfactants. In this way the microrheology parameters of the shell were determined. In a previous paper (Chem. Commun., 2013, 49, 5763-5765) we showed that these systems could be used as ultrasound contrast agents (UCAs). In this work we substantiate this view assessing some key features offered by the viscoelastic nature of the droplet shell. PMID:26931337

  1. A Novel Procedure for Rapid Imaging of Adult Mouse Brains with MicroCT Using Iodine-Based Contrast

    PubMed Central

    Anderson, Ryan; Maga, A. Murat

    2015-01-01

    High-resolution Magnetic Resonance Imaging (MRI) has been the primary modality for obtaining 3D cross-sectional anatomical information in animals for soft tissue, particularly brain. However, costs associated with MRI can be considerably high for large phenotypic screens for gross differences in the structure of the brain due to pathology and/or experimental manipulations. MicroCT (mCT), especially benchtop mCT, is becoming a common laboratory equipment with throughput rates equal or faster than any form of high-resolution MRI at lower costs. Here we explore adapting previously developed contrast based mCT to image adult mouse brains in-situ. We show that 2% weight per volume (w/v) iodine-potassium iodide solution can be successfully used to image adult mouse brains within 48 hours post-mortem when a structural support matrix is used. We demonstrate that hydrogel can be effectively used as a perfusant which limits the tissue shrinkage due to iodine. PMID:26571123

  2. Experimental characterization, comparison and image quality assessment of two ultrasound contrast agents: Optison and Definity

    NASA Astrophysics Data System (ADS)

    Hughes, Amy C.; Day, Steven W.; Linte, Cristian A.; Schwarz, Karl Q.

    2016-04-01

    Microbubble-based contrast agents are commonly used in ultrasound imaging to help differentiate the blood pool from the endocardial wall. It is essential to use an agent which produces high image intensity relative to the surrounding tissue, commonly referred to contrast effect. When exposed to ultrasound waves, microbubbles produce an intense backscatter signal in addition to the contrast produced by the fluctuating size of the microbubbles. However, over time, the microbubble concentration depletes, leading to reduced visual enhancement. The retention time associated with contrast effect varies according to the frequency and power level of the ultrasound wave, as well as the contrast agent used. The primary objective of this study was to investigate and identify the most appropriate image acquisition parameters that render optimal contrast effect for two intravenous contrast agents, Optison™ and Definity™. Several controlled in vitro experiments were conducted using an experimental apparatus that featured a perfused tissue-emulating phantom. A continuous flow of contrast agent was imaged using ultrasound at different frequencies and power levels, while a pulse wave Doppler device was used to monitor the concentration of the contrast agent solution. The contrast effect was determined based on the image intensity inside the flow pipe mimicking the blood-pool relative to the intensity of the surrounding phantom material mimicking cardiac tissue. To identify the combination of parameters that yielded optimal visualization for each contrast agent tested, the contrast effect was assessed at different microbubble concentrations and different ultrasound imaging frequencies and transmission power levels.

  3. Is Non-Contrast CT Adequate for the Evaluation of Hepatic Metastasis in Patients Who Cannot Receive Iodinated Contrast Media?

    PubMed Central

    Jee, Han Bum; Park, Min Jung; Lee, Hye Sun; Park, Mi-Suk; Kim, Myeong-Jin; Chung, Yong Eun

    2015-01-01

    Objective To evaluate the appropriateness of follow-up with only non-enhanced CT (NECT) in patients with gastrointestinal cancer. Subjects and Methods This retrospective study included 323 patients with colorectal and gastric cancer who underwent two consecutive CT examinations (CT1 and CT2), including non-contrast and portal venous phase CT images, with an interval of 1 year. Patients were divided into 2 groups: Group A included patients with no hepatic metastasis on CT1 and with or without newly developed metastasis on CT2 to evaluate the diagnostic performance of NECT for detecting newly developed hepatic metastasis; Group B included patients with known hepatic metastasis both on CT1 and CT2 to evaluate the accuracy of NECT for the assessment of hepatic metastasis based on RECIST criteria (version 1.1). Contrast-enhanced CT (CECT) images were considered as reference standards. Results Group A included 172 patients (M:F = 107:65; mean age, 62.6 years). Among them, 57 patients had 95 metastases (mean size, 2.2 ± 1.3 cm). Per patient and per lesion sensitivity for diagnosing newly developed hepatic metastasis was 56.1–66.7% and 52.6–56.8%, respectively. In terms of small metastases (<1.5 cm), per lesion sensitivity was significantly decreased to 28.1–34.4% (P < 0.05). Metastasis size measurements were significantly smaller on NECT (P < 0.001) compared with reference standards. In Group B, the accuracy of response evaluation based on RECIST criteria was 65.6–72.2%. Conclusions NECT showed inadequate diagnostic performances in both detecting newly developed hepatic metastasis and evaluating the response of hepatic metastasis based on RECIST criteria. PMID:26218533

  4. Do Iodine Contrast Media Compounds Used for Medical Imaging Contribute to the Formation of Iodinated Disinfection By-Products in Drinking Water?

    EPA Science Inventory

    Iodinated disinfection byproducts (DBPs) have recently gained attention due to their cyto- and genotoxicity and increased formation in drinking water treated with chloramine, which has become an increasingly popular disinfectant in the United States. One of these—iodoacetic acid...

  5. Avoidable errors in dealing with anaphylactoid reactions to iodinated contrast media.

    PubMed

    Segal, Arthur J; Bush, William H

    2011-03-01

    Contrast reactions are much less common today than in the past. This is principally because of the current and predominant use of low and iso-osmolar contrast media compared with the prior use of high osmolality contrast media. As a result of the significantly diminished frequency, there are now fewer opportunities for physicians to recognize and appropriately treat such adverse reactions. In review of the literature combined with our own clinical and legal experience, 12 potential errors were identified and these are reviewed in detail so that they can be avoided by the physician-in-charge. Basic treatment considerations are presented along with a plan to systematize an approach to contrast reactions, simplify treatment options and plans, and schedule periodic drills. PMID:21150793

  6. Active extravasation of gadolinium-based contrast agent into the subdural space following lumbar puncture.

    PubMed

    Kothari, Pranay D; Hanser, Evelyn M; Wang, Harrison; Farid, Nikdokht

    2016-01-01

    A 38year-old male presented with cauda equina syndrome following multiple lumbar puncture attempts. Lumbar spine magnetic resonance imaging (MRI) showed a subdural hematoma and an area of apparent contrast enhancement in the spinal canal on sagittal post-contrast images. Axial post-contrast images obtained seven minutes later demonstrated an increase in size and change in shape of the region of apparent contrast enhancement, indicating active extravasation of the contrast agent. This is the first reported case of active extravasation of gadolinium-based contrast agent in the spine. PMID:27317202

  7. Engineering of Nanoscale Contrast Agents for Optical Coherence Tomography

    PubMed Central

    Gordon, Andrew Y; Jayagopal, Ashwath

    2014-01-01

    Optical coherence tomography has emerged as valuable imaging modalityin ophthalmology and other fields by enabling high-resolution three-dimensional imaging of tissue. In this paper, we review recent progress in the field of contrast-enhanced optical coherence tomography (OCT). We discuss exogenous and endogenous sources of OCT contrast, focusing on their use with standard OCT systems as well as emerging OCT-based imaging modalities. We include advances in the processing of OCT data that generate improved tissue contrast, including spectroscopic OCT (SOCT), as well as work utilizing secondary light sources and/or detection mechanisms to create and detect enhanced contrast, including photothermal OCT (PTOCT) and photoacoustic OCT (PAOCT). Finally, we conclude with a discussion of the translational potential of these developments as well as barriers to their clinical use. PMID:25009761

  8. Intravascular contrast agent improves magnetic resonance angiography of carotid arteries in minipigs.

    PubMed

    Lin, W; Abendschein, D R; Celik, A; Dolan, R P; Lauffer, R B; Walovitch, R C; Haacke, E M

    1997-01-01

    This study was designed to optimize three-dimensional (3D) time-of-flight (TOF) magnetic resonance angiography (MRA) sequences and to determine whether contrast-enhanced MRA could improve the accuracy of lumen definition in stenosed carotid arteries of minipigs. 3D TOF MRA was acquired with use of either an intravascular (n = 13) and/or an extravascular contrast agent (n = 5) administrated at 2 to 4 weeks after balloon-induced injury to a carotid artery in 16 minipigs. Vascular contrast, defined as signal intensity differences between blood vessels and muscle normalized to the signal intensity of muscle, was compared before and after the injection of each contrast agent and between the two agents. Different vascular patencies were observed among the animals, including completely occluded vessels (n = 5), stenotic vessels (n = 3), and vessels with no visible stenosis (n = 8). Superior vascular contrast improvement was observed for small arteries and veins and for large veins with the intravascular contrast agent when compared with the extravascular contrast agent. In addition, preliminary studies in two of the animals showed a good correlation for the extent of luminal stenosis defined by digital subtraction angiography compared with MRA obtained after administration of the intravascular contrast agent (R2 = .71, with a slope of .96 +/- .04 by a linear regression analysis). We concluded that use of an intravascular contrast agent optimizes 3D TOF MRA and may improve its accuracy compared with digital subtraction angiography. PMID:9400838

  9. Impact of iodinated contrast injections on percent diameter coronary arterial stenosis and implications for trials of intracoronary pharmacotherapies in patients with ST-elevation myocardial infarction.

    PubMed

    Gibson, C Michael; Buros, Jacqueline; Ciaglo, Lauren N; Southard, Matthew C; Takao, Shaun; Harrigan, Caitlin; Filopei, Jason; Lew, Michelle; Marble, Susan J; Murphy, Sabina A; Cohen, Mauricio G

    2007-07-01

    Administration of fibrinolytic, antiplatelet, and antithrombotic agents by the intracoronary route may disaggregate clot, but the potential role of the mechanical force of the injection itself in decreasing clot burden has not been studied. Patients with ST-segment elevation myocardial infarction who were pretreated in the emergency room (ER) with unfractionated heparin and aspirin in the TITAN-TIMI 34 study were randomized to treatment with eptifibatide in the ER (n = 131) versus after diagnostic catheterization (n = 150). Quantitative coronary angiography was used to assess change in diameter stenosis from time of first contrast injection to injection before percutaneous coronary intervention (PCI) immediately preceding wire placement down the culprit artery in a matching view. Successful perfusion of the myocardium was assessed after PCI by the presence of Thrombolysis In Myocardial Infarction myocardial perfusion grade of 2 or 3. In patients treated with eptifibatide in the ER, there was a 1.3% absolute improvement in diameter stenosis from the first injection to the injection before PCI (p = 0.02), whereas there was no change in diameter stenosis in patients not treated with eptifibatide in the ER (0.0%, p = NS). Each 1% improvement in percent diameter stenosis during diagnostic injections before PCI was strongly correlated with an open muscle after PCI (adjusted odds ratio 1.09, 95% confidence interval 1.02 to 1.16, p = 0.012). In conclusion, the mechanical force of a contrast injection decreases thrombotic burden in patients with ST-segment elevation myocardial infarction pretreated with eptifibatide but not with placebo. Future trials of intracoronary pharmacotherapies should include a control arm in which saline is injected to account for the potential clot disaggregation that occurs as a result of iodinated contrast injections, particularly if the patient has been pretreated with aggressive pharmacotherapy. PMID:17599433

  10. Synthetic Ni3S2/Ni hybrid architectures as potential contrast agents in MRI

    NASA Astrophysics Data System (ADS)

    Ma, J.; Chen, K.

    2016-04-01

    Traditional magnetic resonance imaging (MRI) contrast agents mainly include superparamagnetic (SPM) iron oxide nanoparticle as T 2 contrast agent for liver and paramagnetic Gd (III)-chelate as T 1 contrast agent for all organs. In this work, weak ferromagnetic kale-like and SPM cabbage-like Ni3S2@Ni hybrid architectures were synthesized and evaluated as potential T 1 MRI contrast agents. Their relatively small r 2/r 1 ratios of 2.59 and 2.38, and high r 1 values of 11.27 and 4.89 mmol‑1 L s‑1 (for the kale-like and cabbage-like Ni3S2@Ni, respectively) will shed some light on the development of new-type MRI contrast agents.

  11. X-ray spatial frequency heterodyne imaging of protein-based nanobubble contrast agents.

    PubMed

    Rand, Danielle; Uchida, Masaki; Douglas, Trevor; Rose-Petruck, Christoph

    2014-09-22

    Spatial Frequency Heterodyne Imaging (SFHI) is a novel x-ray scatter imaging technique that utilizes nanoparticle contrast agents. The enhanced sensitivity of this new technique relative to traditional absorption-based x-ray radiography makes it promising for applications in biomedical and materials imaging. Although previous studies on SFHI have utilized only metal nanoparticle contrast agents, we show that nanomaterials with a much lower electron density are also suitable. We prepared protein-based "nanobubble" contrast agents that are comprised of protein cage architectures filled with gas. Results show that these nanobubbles provide contrast in SFHI comparable to that of gold nanoparticles of similar size. PMID:25321797

  12. X-ray spatial frequency heterodyne imaging of protein-based nanobubble contrast agents

    PubMed Central

    Rand, Danielle; Uchida, Masaki; Douglas, Trevor; Rose-Petruck, Christoph

    2014-01-01

    Spatial Frequency Heterodyne Imaging (SFHI) is a novel x-ray scatter imaging technique that utilizes nanoparticle contrast agents. The enhanced sensitivity of this new technique relative to traditional absorption-based x-ray radiography makes it promising for applications in biomedical and materials imaging. Although previous studies on SFHI have utilized only metal nanoparticle contrast agents, we show that nanomaterials with a much lower electron density are also suitable. We prepared protein-based “nanobubble” contrast agents that are comprised of protein cage architectures filled with gas. Results show that these nanobubbles provide contrast in SFHI comparable to that of gold nanoparticles of similar size. PMID:25321797

  13. Noninvasive visualization of in vivo release and intratumoral distribution of surrogate MR contrast agent using the dual MR contrast technique.

    PubMed

    Onuki, Yoshinori; Jacobs, Igor; Artemov, Dmitri; Kato, Yoshinori

    2010-09-01

    A direct evaluation of the in vivo release profile of drugs from carriers is a clinical demand in drug delivery systems, because drug release characterized in vitro correlates poorly with in vivo release. The purpose of this study is to demonstrate the in vivo applicability of the dual MR contrast technique as a useful tool for noninvasive monitoring of the stability and the release profile of drug carriers, by visualizing in vivo release of the encapsulated surrogate MR contrast agent from carriers and its subsequent intratumoral distribution profile. The important aspect of this technique is that it incorporates both positive and negative contrast agents within a single carrier. GdDTPA, superparamagnetic iron oxide nanoparticles, and 5-fluorouracil were encapsulated in nano- and microspheres composed of poly(D,L-lactide-co-glycolide), which was used as a model carrier. In vivo studies were performed with orthotopic xenograft of human breast cancer. The MR-based technique demonstrated here has enabled visualization of the delivery of carriers, and release and intratumoral distribution of the encapsulated positive contrast agent. This study demonstrated proof-of-principle results for the noninvasive monitoring of in vivo release and distribution profiles of MR contrast agents, and thus, this technique will make a great contribution to the field. PMID:20580427

  14. Iodinated contrast media cause direct tubular cell damage, leading to oxidative stress, low nitric oxide, and impairment of tubuloglomerular feedback

    PubMed Central

    Liu, Zhi Zhao; Schmerbach, Kristin; Lu, Yuan; Perlewitz, Andrea; Nikitina, Tatiana; Cantow, Kathleen; Seeliger, Erdmann; Persson, Pontus B.; Liu, Ruisheng; Sendeski, Mauricio M.

    2014-01-01

    Iodinated contrast media (CM) have adverse effects that may result in contrast-induced acute kidney injury. Oxidative stress is believed to play a role in CM-induced kidney injury. We test the hypothesis that oxidative stress and reduced nitric oxide in tubules are consequences of CM-induced direct cell damage and that increased local oxidative stress may increase tubuloglomerular feedback. Rat thick ascending limbs (TAL) were isolated and perfused. Superoxide and nitric oxide were quantified using fluorescence techniques. Cell death rate was estimated using propidium iodide and trypan blue. The function of macula densa and tubuloglomerular feedback responsiveness were measured in isolated, perfused juxtaglomerular apparatuses (JGA) of rabbits. The expression of genes related to oxidative stress and the activity of superoxide dismutase (SOD) were investigated in the renal medulla of rats that received CM. CM increased superoxide concentration and reduced nitric oxide bioavailability in TAL. Propidium iodide fluorescence and trypan blue uptake increased more in CM-perfused TAL than in controls, indicating increased rate of cell death. There were no marked acute changes in the expression of genes related to oxidative stress in medullary segments of Henle's loop. SOD activity did not differ between CM and control groups. The tubuloglomerular feedback in isolated JGA was increased by CM. Tubular cell damage and accompanying oxidative stress in our model are consequences of CM-induced direct cell damage, which also modifies the tubulovascular interaction at the macula densa, and may therefore contribute to disturbances of renal perfusion and filtration. PMID:24431205

  15. Feasibility of iodine contrast enhanced CT-scan during a 18F-fluorodeoxyglucose Positron Emission Tomography

    NASA Astrophysics Data System (ADS)

    Houzard, C.; Tychyj, C.; Morelec, I.; Ricard, F.; Got, P.; Cotton, F.; Giammarile, F.; Maintas, D.

    2009-06-01

    OBJECTIVE: this prospective study evaluates the feasibility in current clinical practice of contrast enhanced CT-scan for diagnosis purpose, performed during 18FDG PET-CT study with a PET/CT tomography. METHOD: 25 patients underwent FDG imaging for lymphoma staging. The PET scan was done immediately after the usual low dose CT (lCT). A second CT scan was consequently acquired, by using classical diagnosis CT parameters (dCT) and iodinated contrast. For each patient, all CT attenuation correction (CTAC) PET images were visually compared. Density in Hounsfield units (HU) and maximum Standardized Uptake Value (SUVmax) were then measured on different organs and up to 5 specific lymphoma localizations (total of 294 measurements). RESULTS: Visual analysis was similar for the 2 modalities, without discordant interpretation for the pathologic sites. SUVmax means and standard deviation of each organ for lCTAC and dCTAC were comparable. The equation of the fitted multiple linear regression model was: dCT=0.0748191 + 1.17024*lCT (98.71%; p < 0.01). CONCLUSION: These first results allow the use of injected CT scan, before the PET scan acquisition for lymphoma staging with this PET-CT scan, not affected by the height atomic number and elevated density. A great benefit is therefore obtained on diagnostic, logistic and radioprotection purposes.

  16. Development and characterization of a nano-scale contrast agent.

    PubMed

    Oeffinger, Brian E; Wheatley, Margaret A

    2004-04-01

    Agents injected parenterally must be less than approximately 8 microm diameter in order to traverse the capillaries in the pulmonary bed, but these agents remain in the vasculature until they are eliminated from the body by a variety of mechanisms. Targeting of cells outside the capillaries requires agent diameters of less than approximately 700 nm to enable escape through the larger-than-usual pores that have been noted in the leaky vasculature of a tumor. The objective of this study was to test the feasibility of creating a surfactant-stabilized nano-bubble with favorable acoustic properties, and identify the key parameters that influence size, yield and stability. Size distribution was characterized using laser light scattering. In vitro acoustic enhancement was assessed by generation of dose and time response curves. We previously developed a successful protocol to generate gas-filled microbubbles (containing perfluorocarbon, sulfur hexafluoride or air) with mean diameter of 1.5 microm, using sonication of carefully selected surfactant mixtures. This presentation describes generation of nano-bubbles with mean diameters ranging from 700 to 450 nm, depending on process variables. In all cases a centrifugation step was employed to separate the nano-sized particles. The in vitro dose response curves gave a maximum of 23-27 dB enhancement compared to buffer in the absence of agent, with the maximum enhancement and presence of shadowing at higher doses being dependent on the fabrication protocol. The effect of sonication time for solutions containing a mixture of the surfactants (Span 60 and Tween 80) was also tested, but was determined not to be an influencing factor. Future studies will involve development of a mathematical model characterizing the mean size as a function of centrifugal force, spin time and initial size distribution. Future work will also include imaging of tumor-bearing mice and measuring imaging potential in vivo in New Zealand white rabbits

  17. Diffusion coefficients of articular cartilage for different CT and MRI contrast agents.

    PubMed

    Kulmala, K A M; Korhonen, R K; Julkunen, P; Jurvelin, J S; Quinn, T M; Kröger, H; Töyräs, J

    2010-10-01

    In contrast enhanced magnetic resonance imaging (MRI) and computed tomography (CT), the equilibrium distribution of anionic contrast agent is expected to reflect the fixed charged density (FCD) of articular cartilage. Diffusion is mainly responsible for the transport of contrast agents into cartilage. In osteoarthritis, cartilage composition changes at early stages of disease, and solute diffusion is most likely affected. Thus, investigation of contrast agent diffusion could enable new methods for imaging of cartilage composition. The aim of this study was to determine the diffusion coefficient of four contrast agents (ioxaglate, gadopentetate, iodide, gadodiamide) in bovine articular cartilage. The contrast agents were different in molecular size and charge. In peripheral quantitative CT experiments, penetration of contrast agent into the tissue was allowed either through the articular surface or through deep cartilage. To determine diffusion coefficients, a finite element model based on Fick's law was fitted to experimental data. Diffusion through articular surface was faster than through deep cartilage with every contrast agent. Iodide, being of atomic size, diffused into the cartilage significantly faster (q<0.05) than the other three contrast agents, for either transport direction. The diffusion coefficients of all clinical contrast agents (ioxaglate, gadopentetate and gadodiamide) were relatively low (142.8-253.7 μm(2)/s). In clinical diagnostics, such slow diffusion may not reach equilibrium and this jeopardizes the determination of FCD by standard methods. However, differences between diffusion through articular surface and deep cartilage, that are characterized by different tissue composition, suggest that diffusion coefficients may correlate with cartilage composition. Present method could therefore enable image-based assessment of cartilage composition by determination of diffusion coefficients within cartilage tissue. PMID:20594900

  18. K-edge ratio method for identification of multiple nanoparticulate contrast agents by spectral CT imaging

    PubMed Central

    Ghadiri, H; Ay, M R; Shiran, M B; Soltanian-Zadeh, H

    2013-01-01

    Objective: Recently introduced energy-sensitive X-ray CT makes it feasible to discriminate different nanoparticulate contrast materials. The purpose of this work is to present a K-edge ratio method for differentiating multiple simultaneous contrast agents using spectral CT. Methods: The ratio of two images relevant to energy bins straddling the K-edge of the materials is calculated using an analytic CT simulator. In the resulting parametric map, the selected contrast agent regions can be identified using a thresholding algorithm. The K-edge ratio algorithm is applied to spectral images of simulated phantoms to identify and differentiate up to four simultaneous and targeted CT contrast agents. Results: We show that different combinations of simultaneous CT contrast agents can be identified by the proposed K-edge ratio method when energy-sensitive CT is used. In the K-edge parametric maps, the pixel values for biological tissues and contrast agents reach a maximum of 0.95, whereas for the selected contrast agents, the pixel values are larger than 1.10. The number of contrast agents that can be discriminated is limited owing to photon starvation. For reliable material discrimination, minimum photon counts corresponding to 140 kVp, 100 mAs and 5-mm slice thickness must be used. Conclusion: The proposed K-edge ratio method is a straightforward and fast method for identification and discrimination of multiple simultaneous CT contrast agents. Advances in knowledge: A new spectral CT-based algorithm is proposed which provides a new concept of molecular CT imaging by non-iteratively identifying multiple contrast agents when they are simultaneously targeting different organs. PMID:23934964

  19. Diffusion and near-equilibrium distribution of MRI and CT contrast agents in articular cartilage.

    PubMed

    Silvast, Tuomo S; Kokkonen, Harri T; Jurvelin, Jukka S; Quinn, Thomas M; Nieminen, Miika T; Töyräs, Juha

    2009-11-21

    Charged contrast agents have been used both in vitro and in vivo for estimation of the fixed charge density (FCD) in articular cartilage. In the present study, the effects of molecular size and charge on the diffusion and equilibrium distribution of several magnetic resonance imaging (MRI) and computed tomography (CT) contrast agents were investigated. Full thickness cartilage disks (Ø = 4.0 mm, n = 64) were prepared from fresh bovine patellae. Contrast agent (gadopentetate: Magnevist((R)), gadodiamide: Omniscan, ioxaglate: Hexabrix or sodium iodide: NaI) diffusion was allowed either through the articular surface or through the deep cartilage. CT imaging of the samples was conducted before contrast agent administration and after 1, 5, 9, 16, 25 and 29 h (and with three samples after 2, 3, 4 and 5 days) diffusion using a clinical peripheral quantitative computed tomography (pQCT) instrument. With all contrast agents, the diffusion through the deep cartilage was slower when compared to the diffusion through the articular surface. With ioxaglate, gadopentetate and gadodiamide it took over 29 h for diffusion to reach the near-equilibrium state. The slow diffusion of the contrast agents raise concerns regarding the validity of techniques for FCD estimation, as these contrast agents may not reach the equilibrium state that is assumed. However, since cartilage composition, i.e. deep versus superficial, had a significant effect on diffusion, imaging of the nonequilibrium diffusion process might enable more accurate assessment of cartilage integrity. PMID:19864699

  20. Intraarterial CT Angiography Using Ultra Low Volume of Iodine Contrast – Own Experiences

    PubMed Central

    Garcarek, Jerzy; Kurcz, Jacek; Guziński, Maciej; Banasik, Mirosław; Miś, Marcin; Gołębiowski, Tomasz

    2015-01-01

    Summary Background High volume of intravenous contrast in CT-angiography may result in contrast-induced nephropathy. Intraarterial ultra-low volume of contrast medium results in its satisfactory blood concentration with potentially good image quality. The first main purpose was to assess the influence of the method on function of transplanted kidney in patients with impaired graft function. The second main purpose of the study was to evaluate the usefulness of this method for detection of gastrointestinal and head-and-neck haemorrhages. Material/Methods Between 2010 and 2013 intraarterial CT-angiography was performed in 56 patients, including 28 with chronic kidney disease (CKD). There were three main subgroups: 18 patients after kidney transplantation, 10 patients with gastrointestinal hemorrhage, 8 patients with head-and-neck hemorrhage. Contralateral or ipsilateral inguinal arterial approach was performed. The 4-French vascular sheaths and 4F-catheters were introduced under fluoroscopy. Intraarterial CT was performed using 64-slice scanner. The scanning protocol was as follows: slice thickness 0.625 mm, pitch 1.3, gantry rotation 0.6 sec., scanning delay 1–2 sec. The extent of the study was established on the basis of scout image. In patients with CKD 6–8 mL of Iodixanol (320 mg/mL) diluted with saline to 18–24 mL was administered at a speed of 4–5 mL/s. Results Vasculature was properly visualized in all patients. In patients with impaired renal function creatinine/eGFR levels remained stable in all but one case. Traditional arteriography failed and CT-angiography demonstrated the site of bleeding in 3 of 10 patients with symptoms of gastrointestinal bleeding (30%). In 8 patients with head-and-neck bleeding CT-angiography did not prove beneficial when compared to traditional arteriography. Conclusions 1. Ultra-low contrast intraarterial CT-angiography does not deteriorate the function of transplanted kidneys in patients with impaired graft function. 2. 3

  1. Synthesis, Characterization, and X-ray Attenuation Properties of Ultrasmall BiOI Nanoparticles: Toward Renal Clearable Particulate CT Contrast Agents

    PubMed Central

    2015-01-01

    A unique decelerated hydrolytic procedure is developed and reported here for the preparation of ultrasmall nanoparticles (NPs) of PVP-coated BiOI with a narrow size distribution, i.e., 2.8 ± 0.5 nm. The crystal structure of this compound is determined by X-ray powder diffraction using the bulk materials. The stability, cytotoxicity, and potential use of the PVP-coated ultrasmall BiOI NPs as a CT contrast agent are investigated. Because of the combined X-ray attenuation effect of bismuth and iodine, such NPs exhibit a CT value that is among the best of those of the inorganic nanoparticle-based CT contrast agents reported in the literature. PMID:25283335

  2. Motion corrected photoacoustic difference imaging of fluorescent contrast agents

    NASA Astrophysics Data System (ADS)

    Märk, Julia; Wagener, Asja; Pönick, Sarah; Grötzinger, Carsten; Zhang, Edward; Laufer, Jan

    2016-03-01

    In fluorophores, such as exogenous dyes and genetically expressed proteins, the excited state lifetime can be modulated using pump-probe excitation at wavelengths corresponding to the absorption and fluorescence spectra. Simultaneous pump-probe pulses induce stimulated emission (SE) which, in turn, modulates the thermalized energy, and hence the photoacoustic (PA) signal amplitude. For time-delayed pulses, by contrast, SE is suppressed. Since this is not observed in endogenous chromophores, the location of the fluorophore can be determined by subtracting images acquired using simultaneous and time-delayed pump-probe excitation. This simple experimental approach exploits a fluorophorespecific contrast mechanism, and has the potential to enable deep-tissue molecular imaging at fluences below the MPE. In this study, some of the challenges to its in vivo implementation are addressed. First, the PA signal amplitude generated in fluorophores in vivo is often much smaller than that in blood. Second, tissue motion can give rise to artifacts that correspond to endogenous chromophores in the difference image. This would not allow the unambiguous detection of fluorophores. A method to suppress motion artifacts based on fast switching between simultaneous and time-delayed pump-probe excitation was developed. This enables the acquisition of PA signals using the two excitation modes with minimal time delay (20 ms), thus minimizing the effects of tissue motion. The feasibility of this method is demonstrated by visualizing a fluorophore (Atto680) in tissue phantoms, which were moved during the image acquisition to mimic tissue motion.

  3. Liver-specific agents for contrast-enhanced MRI: role in oncological imaging

    PubMed Central

    Thian, Yee Liang; Riddell, Angela M.

    2013-01-01

    Abstract Liver-specific magnetic resonance (MR) contrast agents are increasingly used in evaluation of the liver. They are effective in detection and morphological characterization of lesions, and can be useful for evaluation of biliary tree anatomy and liver function. The typical appearances and imaging pitfalls of various tumours at MR imaging performed with these agents can be understood by the interplay of pharmacokinetics of these contrast agents and transporter expression of the tumour. This review focuses on the applications of these agents in oncological imaging. PMID:24434892

  4. Moxifloxacin: Clinically compatible contrast agent for multiphoton imaging

    PubMed Central

    Wang, Taejun; Jang, Won Hyuk; Lee, Seunghun; Yoon, Calvin J.; Lee, Jun Ho; Kim, Bumju; Hwang, Sekyu; Hong, Chun-Pyo; Yoon, Yeoreum; Lee, Gilgu; Le, Viet-Hoan; Bok, Seoyeon; Ahn, G-One; Lee, Jaewook; Gho, Yong Song; Chung, Euiheon; Kim, Sungjee; Jang, Myoung Ho; Myung, Seung-Jae; Kim, Myoung Joon; So, Peter T. C.; Kim, Ki Hean

    2016-01-01

    Multiphoton microscopy (MPM) is a nonlinear fluorescence microscopic technique widely used for cellular imaging of thick tissues and live animals in biological studies. However, MPM application to human tissues is limited by weak endogenous fluorescence in tissue and cytotoxicity of exogenous probes. Herein, we describe the applications of moxifloxacin, an FDA-approved antibiotic, as a cell-labeling agent for MPM. Moxifloxacin has bright intrinsic multiphoton fluorescence, good tissue penetration and high intracellular concentration. MPM with moxifloxacin was demonstrated in various cell lines, and animal tissues of cornea, skin, small intestine and bladder. Clinical application is promising since imaging based on moxifloxacin labeling could be 10 times faster than imaging based on endogenous fluorescence. PMID:27283889

  5. Moxifloxacin: Clinically compatible contrast agent for multiphoton imaging.

    PubMed

    Wang, Taejun; Jang, Won Hyuk; Lee, Seunghun; Yoon, Calvin J; Lee, Jun Ho; Kim, Bumju; Hwang, Sekyu; Hong, Chun-Pyo; Yoon, Yeoreum; Lee, Gilgu; Le, Viet-Hoan; Bok, Seoyeon; Ahn, G-One; Lee, Jaewook; Gho, Yong Song; Chung, Euiheon; Kim, Sungjee; Jang, Myoung Ho; Myung, Seung-Jae; Kim, Myoung Joon; So, Peter T C; Kim, Ki Hean

    2016-01-01

    Multiphoton microscopy (MPM) is a nonlinear fluorescence microscopic technique widely used for cellular imaging of thick tissues and live animals in biological studies. However, MPM application to human tissues is limited by weak endogenous fluorescence in tissue and cytotoxicity of exogenous probes. Herein, we describe the applications of moxifloxacin, an FDA-approved antibiotic, as a cell-labeling agent for MPM. Moxifloxacin has bright intrinsic multiphoton fluorescence, good tissue penetration and high intracellular concentration. MPM with moxifloxacin was demonstrated in various cell lines, and animal tissues of cornea, skin, small intestine and bladder. Clinical application is promising since imaging based on moxifloxacin labeling could be 10 times faster than imaging based on endogenous fluorescence. PMID:27283889

  6. Tailored Near-Infrared Contrast Agents for Image Guided Surgery

    PubMed Central

    Njiojob, Costyl N.; Owens, Eric A.; Narayana, Lakshminarayana; Hyun, Hoon; Choi, Hak Soo; Henary, Maged

    2015-01-01

    The success of near-infrared (NIR) fluorescence to be employed for intraoperative imaging relies on the ability to develop a highly stable, NIR fluorescent, nontoxic, biocompatible, and highly excreted compound that retains a reactive functionality for conjugation to a cancer-recognizing peptide. Herein, systematic modifications to previously detailed fluorophore ZW800-1 are explored. Specific modifications, including the isosteric replacement of the O atom of ZW800-1, include nucleophilic amine and sulfur species attached to the heptamethine core. These novel compounds have shown similar satisfactory results in biodistribution and clearance while also expressing increased stability in serum. Most importantly, all of the synthesized and evaluated compounds display a reactive functionality (either a free amino group or carboxylic acid moiety) for further bioconjugation. The results obtained from the newly prepared derivatives demonstrate that the central substitution with the studied linking agents retains the ultralow background in vivo performance of the fluorophores regardless of the total net charge. PMID:25711712

  7. Moxifloxacin: Clinically compatible contrast agent for multiphoton imaging

    NASA Astrophysics Data System (ADS)

    Wang, Taejun; Jang, Won Hyuk; Lee, Seunghun; Yoon, Calvin J.; Lee, Jun Ho; Kim, Bumju; Hwang, Sekyu; Hong, Chun-Pyo; Yoon, Yeoreum; Lee, Gilgu; Le, Viet-Hoan; Bok, Seoyeon; Ahn, G.-One; Lee, Jaewook; Gho, Yong Song; Chung, Euiheon; Kim, Sungjee; Jang, Myoung Ho; Myung, Seung-Jae; Kim, Myoung Joon; So, Peter T. C.; Kim, Ki Hean

    2016-06-01

    Multiphoton microscopy (MPM) is a nonlinear fluorescence microscopic technique widely used for cellular imaging of thick tissues and live animals in biological studies. However, MPM application to human tissues is limited by weak endogenous fluorescence in tissue and cytotoxicity of exogenous probes. Herein, we describe the applications of moxifloxacin, an FDA-approved antibiotic, as a cell-labeling agent for MPM. Moxifloxacin has bright intrinsic multiphoton fluorescence, good tissue penetration and high intracellular concentration. MPM with moxifloxacin was demonstrated in various cell lines, and animal tissues of cornea, skin, small intestine and bladder. Clinical application is promising since imaging based on moxifloxacin labeling could be 10 times faster than imaging based on endogenous fluorescence.

  8. Contrasting actions of pressor agents in severe autonomic failure

    NASA Technical Reports Server (NTRS)

    Jordan, J.; Shannon, J. R.; Biaggioni, I.; Norman, R.; Black, B. K.; Robertson, D.

    1998-01-01

    BACKGROUND: Orthostatic hypotension is the most disabling symptom of autonomic failure. The choice of a pressor agent is largely empiric, and it would be of great value to define predictors of a response. PATIENTS AND METHODS: In 35 patients with severe orthostatic hypotension due to multiple system atrophy or pure autonomic failure, we determined the effect on seated systolic blood pressure (SBP) of placebo, phenylpropanolamine (12.5 mg and 25 mg), yohimbine (5.4 mg), indomethacin (50 mg), ibuprofen (600 mg), caffeine (250 mg), and methylphenidate (5 mg). In a subgroup of patients, we compared the pressor effect of midodrine (5 mg) with the effect of phenylpropanolamine (12.5 mg). RESULTS: There were no significant differences in the pressor responses between patients with multiple system atrophy or pure autonomic failure. When compared with placebo, the pressor response was significant for phenylpropanolamine, yohimbine, and indomethacin. In a subgroup of patients, we confirmed that this pressor effect of phenylpropanolamine, yohimbine, and indomethacin corresponded to a significant increase in standing SBP. The pressor responses to ibuprofen, caffeine, and methylphenidate were not significantly different from placebo. Phenylpropanolamine and midodrine elicited similar pressor responses. There were no significant associations between drug response and autonomic function testing, postprandial hypotension, or plasma catecholamine levels. CONCLUSIONS: We conclude that significant increases in systolic blood pressure can be obtained in patients with orthostatic hypotension due to primary autonomic failure with phenylpropanolamine in low doses or yohimbine or indomethacin in moderate doses. The response to a pressor agent cannot be predicted by autonomic function testing or plasma catecholamines. Therefore, empiric testing with a sequence of medications, based on the risk of side effects in the individual patient and the probability of a response, is a useful approach.

  9. Superparamagnetic And Paramagnetic MRI Contrast Agents: Application Of Rapid Magnetic Resonance Imaging To Assess Renal Function

    NASA Astrophysics Data System (ADS)

    Carvlin, Mark J.; Renshaw, Perry F.; Arger, Peter; Kundel, Harold L.; Dougherty, Larry; Axel, Leon; Kassab, Eleanor; Moore, Bethanne

    1988-06-01

    The paramagnetic chelate complex, gadolinium-diethylene-triamine-pentaacetic acid, Gd-DTPA, and superparamagnetic particles, such as those composed of dextran coated magnetite, function as magnetic resonance contrast agents by changing the relaxation rates, 1/T1 and 1/T2. The effects that these agents have upon MR signal intensity are determined by: the inherent biophysical properties of the tissue being imaged, the concentration of the contrast agent and the data acquisition scheme (pulse sequence parameters) employed. Following the time course of MR signal change in the first minutes after the injection of contrast agent(s) allows a dynamic assessment of organ functions in a manner analogous to certain nuclear medicine studies. In order to study renal function, sequential MR fast scan images, gradient echo (TR=35/TE=7 msec, flip angle=25 degrees), were acquired, one every 12 seconds, after intravenous injection of Gd-DTPA and/or dextran-magnetite. Gd-DTPA, which is freely filtered at the glomerulus and is neither secreted nor reabsorbed, provides information concerning renal perfusion, glomerular filtration and tubular concentrating ability. Dextran-magnetite (200 A diameter), which is primarily contained within the intravascular space shortly after injection, provides information on blood flow to and distribution within the kidney. The MR signal change observed after administration of contrast agents varied dramatically depending upon the agents injected and the imaging parameters used. Hence a broad range of physiolgic processes may be described using these techniques, i.e. contrast agent enhanced functional MR examinations.

  10. Design Principles of Nanoparticles as Contrast Agents for Magnetic Resonance Imaging

    NASA Astrophysics Data System (ADS)

    Shan, Liang; Gu, Xinbin; Wang, Paul

    2013-09-01

    Molecular imaging is an emerging field that introduces molecular agents into traditional imaging techniques, enabling visualization, characterization and measurement of biological processes at the molecular and cellular levels in humans and other living systems. The promise of molecular imaging lies in its potential for selective potency by targeting biomarkers or molecular targets and the imaging agents serve as reporters for the selectivity of targeting. Development of an efficient molecular imaging agent depends on well-controlled high-quality experiment design involving target selection, agent synthesis, in vitro characterization, and in vivo animal characterization before it is applied in humans. According to the analysis from the Molecular Imaging and Contrast Agent Database (MICAD, ), more than 6000 molecular imaging agents with sufficient preclinical evaluation have been reported to date in the literature and this number increases by 250-300 novel agents each year. The majority of these agents are radionuclides, which are developed for positron emission tomography (PET) and single photon emission computed tomography (SPECT). Contrast agents for magnetic resonance imaging (MRI) account for only a small part. This is largely due to the fact that MRI is currently not a fully quantitative imaging technique and is less sensitive than PET and SPECT. However, because of the superior ability to simultaneously extract molecular and anatomic information, molecular MRI is attracting significant interest and various targeted nanoparticle contrast agents have been synthesized for MRI. The first and one of the most critical steps in developing a targeted nanoparticle contrast agent is target selection, which plays the central role and forms the basis for success of molecular imaging. This chapter discusses the design principles of targeted contrast agents in the emerging frontiers of molecular MRI.

  11. Modified polysaccharides as potential (19)F magnetic resonance contrast agents.

    PubMed

    Krawczyk, Tomasz; Minoshima, Masafumi; Sugihara, Fuminori; Kikuchi, Kazuya

    2016-06-16

    The introduction of 3-aminobenzotrifluoride into partially oxidized alginic acid, dextran, and polygalacturonic acid (10-100 kDa) by means of the imine formation and a subsequent reduction resulted in water-soluble materials containing 1-14% of fluorine. They showed a single or split (19)F NMR signal in a narrow range of -63 to -63.5 ppm. The observed T1 and T2 were approximately 1 and 0.2 s at 400 or 500 MHz instruments, respectively. The samples showed low toxicity and uptake toward the HeLa cells similar to native polysaccharides and were preferentially localized in lysosomes. A tail intravenous injection of 5 mg of modified dextran containing 1% of fluorine revealed that the probe was not trapped in liver, spleen or kidneys, but was quickly cleared with urine. The proposed materials can be used for imaging of the gastrointestinal tract or the genitourinary system and act as a material for more complex (19)F MRI agent synthesis. PMID:27148998

  12. Nanoparticles in magnetic resonance imaging: from simple to dual contrast agents

    PubMed Central

    Estelrich, Joan; Sánchez-Martín, María Jesús; Busquets, Maria Antònia

    2015-01-01

    Magnetic resonance imaging (MRI) has become one of the most widely used and powerful tools for noninvasive clinical diagnosis owing to its high degree of soft tissue contrast, spatial resolution, and depth of penetration. MRI signal intensity is related to the relaxation times (T1, spin–lattice relaxation and T2, spin–spin relaxation) of in vivo water protons. To increase contrast, various inorganic nanoparticles and complexes (the so-called contrast agents) are administered prior to the scanning. Shortening T1 and T2 increases the corresponding relaxation rates, 1/T1 and 1/T2, producing hyperintense and hypointense signals respectively in shorter times. Moreover, the signal-to-noise ratio can be improved with the acquisition of a large number of measurements. The contrast agents used are generally based on either iron oxide nanoparticles or ferrites, providing negative contrast in T2-weighted images; or complexes of lanthanide metals (mostly containing gadolinium ions), providing positive contrast in T1-weighted images. Recently, lanthanide complexes have been immobilized in nanostructured materials in order to develop a new class of contrast agents with functions including blood-pool and organ (or tumor) targeting. Meanwhile, to overcome the limitations of individual imaging modalities, multimodal imaging techniques have been developed. An important challenge is to design all-in-one contrast agents that can be detected by multimodal techniques. Magnetoliposomes are efficient multimodal contrast agents. They can simultaneously bear both kinds of contrast and can, furthermore, incorporate targeting ligands and chains of polyethylene glycol to enhance the accumulation of nanoparticles at the site of interest and the bioavailability, respectively. Here, we review the most important characteristics of the nanoparticles or complexes used as MRI contrast agents. PMID:25834422

  13. The evolution of gadolinium based contrast agents: from single-modality to multi-modality.

    PubMed

    Zhang, Li; Liu, Ruiqing; Peng, Hui; Li, Penghui; Xu, Zushun; Whittaker, Andrew K

    2016-05-19

    Gadolinium-based contrast agents are extensively used as magnetic resonance imaging (MRI) contrast agents due to their outstanding signal enhancement and ease of chemical modification. However, it is increasingly recognized that information obtained from single modal molecular imaging cannot satisfy the higher requirements on the efficiency and accuracy for clinical diagnosis and medical research, due to its limitation and default rooted in single molecular imaging technique itself. To compensate for the deficiencies of single function magnetic resonance imaging contrast agents, the combination of multi-modality imaging has turned to be the research hotpot in recent years. This review presents an overview on the recent developments of the functionalization of gadolinium-based contrast agents, and their application in biomedicine applications. PMID:27159645

  14. Acoustic responses of monodisperse lipid-encapsulated microbubble contrast agents produced by flow focusing

    PubMed Central

    Kaya, Mehmet; Feingold, Steven; Hettiarachchi, Kanaka; Lee, Abraham P; Dayton, Paul A

    2010-01-01

    Lipid-encapsulated microbubbles are used as contrast agents in ultrasound imaging. Currently available commercially made contrast agents have a polydisperse size distribution. It has been hypothesised that improved imaging sensitivity could be achieved with a uniform microbubble radius. We have recently developed microfluidics technology to produce contrast agents with a nearly monodisperse distribution. In this manuscript, we analyze echo responses from individual microbubbles from monodisperse populations in order to establish the relationship between scattered echo, microbubble radius, and excitation frequency. Simulations of bubble response from a modified Rayleigh-Plesset type model corroborate experimental data. Results indicate that microbubble echo response can be greatly increased by optimal combinations of microbubble radius and acoustic excitation frequency. These results may have a significant impact in the formulation of contrast agents to improve ultrasonic sensitivity. PMID:21475641

  15. The evolution of gadolinium based contrast agents: from single-modality to multi-modality

    NASA Astrophysics Data System (ADS)

    Zhang, Li; Liu, Ruiqing; Peng, Hui; Li, Penghui; Xu, Zushun; Whittaker, Andrew K.

    2016-05-01

    Gadolinium-based contrast agents are extensively used as magnetic resonance imaging (MRI) contrast agents due to their outstanding signal enhancement and ease of chemical modification. However, it is increasingly recognized that information obtained from single modal molecular imaging cannot satisfy the higher requirements on the efficiency and accuracy for clinical diagnosis and medical research, due to its limitation and default rooted in single molecular imaging technique itself. To compensate for the deficiencies of single function magnetic resonance imaging contrast agents, the combination of multi-modality imaging has turned to be the research hotpot in recent years. This review presents an overview on the recent developments of the functionalization of gadolinium-based contrast agents, and their application in biomedicine applications.

  16. Pulmonary 64-MDCT angiography with 50 mL of iodinated contrast material in an unselected patient population: a feasible protocol*

    PubMed Central

    Trad, Henrique Simão; Boasquevisque, Gustavo Santos; Giacometti, Tiago Rangon; Trad, Catherine Yang; Zoghbi Neto, Orlando Salomão; Trad, Clovis Simão

    2016-01-01

    Objective To propose a protocol for pulmonary angiography using 64-slice multidetector computed tomography (64-MDCT) with 50 mL of iodinated contrast material, in an unselected patient population, as well as to evaluate vascular enhancement and image quality. Materials and Methods We evaluated 29 patients (22-86 years of age). The body mass index ranged from 19.0 kg/m2 to 41.8 kg/m2. Patients underwent pulmonary CT angiography in a 64-MDCT scanner, receiving 50 mL of iodinated contrast material via venous access at a rate of 4.5 mL/s. Bolus tracking was applied in the superior vena cava. Two experienced radiologists assessed image quality and vascular enhancement. Results The mean density was 382 Hounsfield units (HU) for the pulmonary trunk; 379 and 377 HU for the right and left main pulmonary arteries, respectively; and 346 and 364 HU for the right and left inferior pulmonary arteries, respectively. In all patients, subsegmental arteries were analyzed. There were streak artifacts from contrast material in the superior vena cava in all patients. However, those artifacts did not impair the image analysis. Conclusion Our findings suggest that pulmonary angiography using 64-MDCT with 50 mL of iodinated contrast can produce high quality images in unselected patient populations. PMID:27141128

  17. Dynamic manipulation of magnetic contrast agents in photoacoustic imaging

    NASA Astrophysics Data System (ADS)

    Jia, Congxian; Xia, Jinjun; Pelivanov, Ivan M.; Seo, Chi Hyung; Hu, Xiaoge; Jin, Yongdong; Gao, Xiaohu; O'Donnell, Matthew

    2011-03-01

    Magnetic nanoparticles (MNPs) have been used extensively ex vivo for cellular and molecular separations. We recently showed that a coupled nanoparticle combining a superparamagnetic core with a thin, isolated gold shell providing strong absorption in the near infrared can be used for magnetomotive photoacoustic imaging (mmPA), a new technique in which magnetic manipulation of the particle during PA imaging greatly enhances molecular contrast specificity. This particle can also be biologically targeted for in vivo applications, where mmPA imaging provides a spatially localized readout of magnetic manipulations. As an initial test of potential in vivo molecular assays and integrated molecular therapeutics using magnetic manipulation of nanoparticles, we present experiments demonstrating PA readout of trapped magnetic particles in a flow field. An aqueous solution containing a concentration of 0.05-mg/ml 10-μM superparamagnetic iron oxide particles flowed in a 1.65-mm diameter Zeus PTFE (Teflon) sublite wall tubing at three velocities of 0.8, 1.5 and 3.0-mm/s. Opposed permanent magnets separated by 40-mm were positioned on both sides of the tube. As expected, the targeted objects can be magnetically captured and accumulated locally. By translating the magnets, a dynamic magnetic field (0.1-0.3-T) was alternately generated on the side of the tube closest to one of the magnets and created a synchronous PA motion from accumulated targeted objects. This synchronized motion can be used to differentiate the stationary background or other PA sources moving asynchronously with magnetic manipulations (e.g., moving blood) from targeted cells moving synchronously with the magnetic field. This technology can potentially provide sensitive molecular assays of cellular targets travelling in the vasculature (e.g., metastatic tumor cells).

  18. Acoustic radiation pressure: A 'phase contrast' agent for x-ray phase contrast imaging

    SciTech Connect

    Bailat, Claude J.; Hamilton, Theron J.; Rose-Petruck, Christoph; Diebold, Gerald J.

    2004-11-08

    We show that the radiation pressure exerted by a beam of ultrasound can be used for contrast enhancement in high-resolution x-ray imaging of tissue and soft materials. Interfacial features of objects are highlighted as a result of both the displacement introduced by the ultrasound and the inherent sensitivity of x-ray phase contrast imaging to density variations. The potential of the method is demonstrated by imaging microscopic tumor phantoms embedded into tissue with a thickness typically presented in mammography. The detection limit of micrometer size masses exceeds the resolution of currently available mammography imaging systems. The directionality of the acoustic radiation force and its localization in space permits the imaging of ultrasound-selected tissue volumes. The results presented here suggest that the method may permit the detection of tumors in soft tissue in their early stage of development.

  19. Submicron polycaprolactone particles as a carrier for imaging contrast agent for in vitro applications.

    PubMed

    Iqbal, Muhammad; Robin, Sophie; Humbert, Philippe; Viennet, Céline; Agusti, Geraldine; Fessi, Hatem; Elaissari, Abdelhamid

    2015-12-01

    Fluorescent materials have recently attracted considerable attention due to their unique properties and high performance as imaging agent in biomedical fields. Different imaging agents have been encapsulated in order to restrict its delivery to a specific area. In this study, a fluorescent contrast agent was encapsulated for in vitro application by polycaprolactone (PCL) polymer. The encapsulation was performed using modified double emulsion solvent evaporation technique with sonication. Fluorescent nanoparticles (20 nm) were incorporated in the inner aqueous phase of double emulsion. A number of samples were fabricated using different concentrations of fluorescent contrast agent. The contrast agent-containing submicron particle was characterized by a zetasizer for average particle size, SEM and TEM for morphology observations and fluorescence spectrophotometer for encapsulation efficiency. Moreover, contrast agent distribution in the PCL matrix was determined by confocal microscopy. The incorporation of contrast agent in different concentrations did not affect the physicochemical properties of PCL particles and the average size of encapsulated particles was found to be in the submicron range. PMID:26454055

  20. Detection of Sulfatase Enzyme Activity with a CatalyCEST MRI Contrast Agent.

    PubMed

    Sinharay, Sanhita; Fernández-Cuervo, Gabriela; Acfalle, Jasmine P; Pagel, Mark D

    2016-05-01

    A chemical exchange saturation transfer (CEST) MRI contrast agent has been developed that detects sulfatase enzyme activity. The agent produces a CEST signal at δ=5.0 ppm before enzyme activity, and a second CEST signal appears at δ=9.0 ppm after the enzyme cleaves a sulfate group from the agent. The comparison of the two signals improved detection of sulfatase activity. PMID:26956002

  1. Evaluation of microbubble contrast agents for dynamic imaging with x-ray phase contrast

    PubMed Central

    Millard, T. P.; Endrizzi, M.; Everdell, N.; Rigon, L.; Arfelli, F.; Menk, R. H.; Stride, E.; Olivo, A.

    2015-01-01

    X-rays are commonly used as a means to image the inside of objects opaque to visible light, as their short wavelength allows penetration through matter and the formation of high spatial resolution images. This physical effect has found particular importance in medicine where x-ray based imaging is routinely used as a diagnostic tool. Increasingly, however, imaging modalities that provide functional as well as morphological information are required. In this study the potential to use x-ray phase based imaging as a functional modality through the use of microbubbles that can be targeted to specific biological processes is explored. We show that the concentration of a microbubble suspension can be monitored quantitatively whilst in flow using x-ray phase contrast imaging. This could provide the basis for a dynamic imaging technique that combines the tissue penetration, spatial resolution, and high contrast of x-ray phase based imaging with the functional information offered by targeted imaging modalities. PMID:26219661

  2. A liposomal Gd contrast agent does not cross the mouse placental barrier.

    PubMed

    Shetty, Anil N; Pautler, Robia; Ghagahda, Ketan; Rendon, David; Gao, Haijun; Starosolski, Zbigniew; Bhavane, Rohan; Patel, Chandreshkumar; Annapragada, Ananth; Yallampalli, Chandrasekhar; Lee, Wesley

    2016-01-01

    The trans-placental permeability of liposomal Gadolinium (Gd) nanoparticle contrast agents was evaluated in a pregnant mouse model. Pregnant Balb/c mice at 16.5 (±1) days of gestation were imaged using a 3D Spoiled Gradient Echo method at 9.4 T using two contrast agents: a clinically approved Gd chelate, Multihance(®) (gadobenate dimeglumine), and a novel experimental liposomal Gd agent. A Dynamic Contrast Enhancement (DCE) protocol was used to capture the dynamics of contrast entry and distribution in the placenta, and clearance from circulation. A blinded clinical radiologist evaluated both sets of images. A reference region model was used to measure the placental flow and physiological parameters; volume transfer constant (K(trans)), efflux rate constant (K(ep)). The Gd content of excised placentae and fetuses was measured, using inductively coupled plasma mass spectrometry (ICP-MS). MRI images of pregnant mice and ICP-MS analyses of placental and fetal tissue demonstrated undetectably low transplacental permeation of the liposomal Gd agent, while the clinical agent (Multihance) avidly permeated the placental barrier. Image interpretation and diagnostic quality was equivalent between the two contrast agents. Additional testing to determine both maternal and fetal safety of liposomal Gd is suggested. PMID:27298076

  3. Efficient mucosal delivery of optical contrast agents using imidazole-modified chitosan

    NASA Astrophysics Data System (ADS)

    Ghosn, Bilal; van de Ven, Anne L.; Tam, Justina; Gillenwater, Ann; Sokolov, Konstantin V.; Richards-Kortum, Rebecca; Roy, Krishnendu

    2010-01-01

    The clinical applicability of antibodies and plasmonic nanosensors as topically applied, molecule-specific optical diagnostic agents for noninvasive early detection of cancer and precancer is severely limited by our inability to efficiently deliver macromolecules and nanoparticles through mucosal tissues. We have developed an imidazole-functionalized conjugate of the polysaccharide chitosan (chitosan-IAA) to enhance topical delivery of contrast agents, ranging from small molecules and antibodies to gold nanoparticles up to 44 nm in average diameter. Contrast agent uptake and localization in freshly resected mucosal tissues was monitored using confocal microscopy. Chitosan-IAA was found to reversibly enhance mucosal permeability in a rapid, reproducible manner, facilitating transepithelial delivery of optical contrast agents. Permeation enhancement occurred through an active process, resulting in the delivery of contrast agents via a paracellular or a combined paracellular/transcellular route depending on size. Coadministration of epidermal growth factor receptor-targeted antibodies with chitosan-IAA facilitated specific labeling and discrimination between paired normal and malignant human oral biopsies. Together, these data suggest that chitosan-IAA is a promising topical permeation enhancer for mucosal delivery of optical contrast agents.

  4. A liposomal Gd contrast agent does not cross the mouse placental barrier

    PubMed Central

    Shetty, Anil N.; Pautler, Robia; Ghagahda, Ketan; Rendon, David; Gao, Haijun; Starosolski, Zbigniew; Bhavane, Rohan; Patel, Chandreshkumar; Annapragada, Ananth; Yallampalli, Chandrasekhar; Lee, Wesley

    2016-01-01

    The trans-placental permeability of liposomal Gadolinium (Gd) nanoparticle contrast agents was evaluated in a pregnant mouse model. Pregnant Balb/c mice at 16.5 (±1) days of gestation were imaged using a 3D Spoiled Gradient Echo method at 9.4 T using two contrast agents: a clinically approved Gd chelate, Multihance® (gadobenate dimeglumine), and a novel experimental liposomal Gd agent. A Dynamic Contrast Enhancement (DCE) protocol was used to capture the dynamics of contrast entry and distribution in the placenta, and clearance from circulation. A blinded clinical radiologist evaluated both sets of images. A reference region model was used to measure the placental flow and physiological parameters; volume transfer constant (Ktrans), efflux rate constant (Kep). The Gd content of excised placentae and fetuses was measured, using inductively coupled plasma mass spectrometry (ICP-MS). MRI images of pregnant mice and ICP-MS analyses of placental and fetal tissue demonstrated undetectably low transplacental permeation of the liposomal Gd agent, while the clinical agent (Multihance) avidly permeated the placental barrier. Image interpretation and diagnostic quality was equivalent between the two contrast agents. Additional testing to determine both maternal and fetal safety of liposomal Gd is suggested. PMID:27298076

  5. Quantitative imaging of cell-permeable magnetic resonance contrast agents using x-ray fluorescence.

    PubMed

    Endres, Paul J; Macrenaris, Keith W; Vogt, Stefan; Allen, Matthew J; Meade, Thomas J

    2006-01-01

    The inability to transduce cellular membranes is a limitation of current magnetic resonance imaging probes used in biologic and clinical settings. This constraint confines contrast agents to extracellular and vascular regions of the body, drastically reducing their viability for investigating processes and cycles in developmental biology. Conversely, a contrast agent with the ability to permeate cell membranes could be used in visualizing cell patterning, cell fate mapping, gene therapy, and, eventually, noninvasive cancer diagnosis. Therefore, we describe the synthesis and quantitative imaging of four contrast agents with the capability to cross cell membranes in sufficient quantity for detection. Each agent is based on the conjugation of a Gd(III) chelator with a cellular transduction moiety. Specifically, we coupled Gd(III)-diethylenetriaminepentaacetic acid DTPA and Gd(III)-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid with an 8-amino acid polyarginine oligomer and an amphipathic stilbene molecule, 4-amino-4'-(N,N-dimethylamino)stilbene. The imaging modality that provided the best sensitivity and spatial resolution for direct detection of the contrast agents is synchrotron radiation x-ray fluorescence (SR-XRF). Unlike optical microscopy, SR-XRF provides two-dimensional images with resolution 10(3) better than (153)Gd gamma counting, without altering the agent by organic fluorophore conjugation. The transduction efficiency of the intracellular agents was evaluated by T(1) analysis and inductively coupled plasma mass spectrometry to determine the efficacy of each chelate-transporter combination. PMID:17150161

  6. Laser-induced photoacoustic tomography enhanced with an optical contrast agent

    NASA Astrophysics Data System (ADS)

    Wang, Xueding; Ku, Geng; Xie, Xueyi; Wegiel, Malgorzata A.; Bornhop, Darryl J.; Stoica, George; Wang, Lihong V.

    2004-07-01

    Optical contrast agents, such as indocyanine dyes, nano-particles and their functional derivatives, have been widely applied to enhance the sensitivity and specificity of optical imaging. However, due to the overwhelming scattering of light in biological tissues, the spatial resolution of traditional optical imaging degrades drastically as the imaging depth increases. For the first time to our knowledge, non-invasive in vivo photoacoustic imaging of an optical contrast agent, distributed in the rat brain, was implemented with near-infrared light. Injection of indocyanine green polyethylene glycol, a contrast agent with a high absorption at the 805-nm wavelength, into the circulatory system of a rat enhanced the absorption contrast between the blood vessels and the background brain tissues. Because near-infrared light can penetrate deep into the brain tissues through the skin and skull, we were able to successfully reconstruct the vascular distribution in the rat brain from the detected photoacoustic signals. The dynamic concentration of this contrast agent in the brain blood after the intravenous injection was also studied. This work proved that the distribution of an exogenous contrast agent in biological tissues can be imaged clearly and accurately by photoacoustic tomography. This new technology has high potential for application in dynamic and molecular medical imaging.

  7. Study of suspending agents for gadolinium(III)-exchanged hectorite. An oral magnetic resonance imaging contrast agent

    SciTech Connect

    Balkus, K.J. Jr.; Shi, J.

    1996-12-25

    Clays modified with paramagnetic ions have been shown to be effective magnetic resonance imaging contrast agents. The efficacy in part relies on the suspension of the small clay particles in aqueous solution. In this study a series of macromolecules were eveluated as suspending agents for Gd(III) ion exchanged hectorite clay in water. The room temperature relaxivities for the Gd-hectorite clays were enhanced by the addition of poly(ethylene oxide), poly(ethylene glycol), cyclodextrins, and cholic acid to aqueous suspensions. Additionally, there was no evidence of free Gd(III) in solution in the presence of these suspending agents. In contrast the combination of alginic acid or poly(sodium 4-styrenesulfonate) with the clays resulted in release of the Gd(III) into solution. Xanthan gum, which is often used as an emulsifier and stabilizer in food products, forms a viscous suspension but also reacts with free Gd(III) ions. 25 refs., 10 figs., 2 tabs.

  8. Contrast agent-induced thrombophlebitis following leg phlebography: meglumine loxaglate versus meglumine lothalamate

    SciTech Connect

    Thomas, M.L.; Briggs, G.M.; Kuan, B.B.

    1983-05-01

    A comparison was made of the incidence of venous thrombophlebitis resulting from the use of a high-osmolality contrast medium (Conray 60%, meglumine ioxaglate) and a low-osmolality contrast medium (Hexabrix 59%, meglumine iothalamate). In 30 patients with varicose veins, Conray was injected into one leg and Hexabrix into the other. The incidence of thrombophlebitis was then determined using the iodine-125 fibrinogen uptake test in a prospective, randomized, double-blind study. There was significantly less thrombophlebitis with Hexabrix than with Conray and the authors conclude that Hexabrix is safer for phlebography. Hexabrix is also stable in solution, only slightly more expensive than Conray, and one fifth the cost of metrizamide.

  9. Structural and functional photoacoustic molecular tomography aided by emerging contrast agents

    PubMed Central

    Nie, Liming

    2015-01-01

    Photoacoustic tomography (PAT) can offer structural, functional and molecular contrasts at scalable observation level. By ultrasonically overcoming the strong optical scattering, this imaging technology can reach centimeters penetration depth while retaining high spatial resolution in biological tissue. Recent extensive research has been focused on developing new contrast agents to improve the imaging sensitivity, specificity and efficiency. These emerging materials have substantially accelerated PAT applications in signal sensing, functional imaging, biomarker labeling and therapy monitoring etc. Here, the potentials of different optical probes as PAT contrast agents were elucidated. We first describe the instrumental embodiments and the measured functional parameters, then focus on emerging contrast agent-based PAT applications, and finally discuss the challenges and prospects. PMID:24967718

  10. High-Relaxivity MRI Contrast Agents: Where Coordination Chemistry Meets Medical Imaging

    SciTech Connect

    Werner, Eric J.; Datta, Ankona; Jocher, Christoph J.; Raymond, Kenneth N.

    2008-01-15

    The desire to improve and expand the scope of clinical magnetic resonance imaging (MRI) has prompted the search for contrast agents of higher efficiency. The development of better agents requires consideration of the fundamental coordination chemistry of the gadolinium(III) ion and the parameters that affect its efficacy as a proton relaxation agent. In optimizing each parameter, other practical issues such as solubility and in vivo toxicity must also be addressed, making the attainment of safe, high-relaxivity agents a challenging goal. Here we present recent advances in the field, with an emphasis on the hydroxypyridinone family of Gd{sup III} chelates.

  11. Thermal Excitation of Gadolinium-Based Contrast Agents Using Spin Resonance

    PubMed Central

    Fridjhon, Peter; Rubin, David M.

    2016-01-01

    Theoretical and experimental investigations into the thermal excitation of liquid paramagnetic contrast agents using the spin resonance relaxation mechanism are presented. The electronic spin-lattice relaxation time τ1e of gadolinium-based contrast agents, which is estimated at 0.1 ns, is ten orders of magnitude faster than the relaxation time of protons in water. The shorter relaxation time is found to significantly increase the rate of thermal energy deposition. To the authors’ knowledge this is the first study of gadolinium based contrast agents in a liquid state used as thermal agents. Analysis shows that when τ1e and other experimental parameters are optimally selected, a maximum theoretical heating rate of 29.4 °C.s−1 could be achieved which would suffice for clinical thermal ablation of neoplasms. The experimental results show a statistically significant thermal response for two out of the four contrast agents tested. The results are compared to the simulated estimates via analysis of a detailed model of the system. While these experimentally determined temperature rises are small and thus of no clinical utility, their presence supports the theoretical analysis and strongly suggests that the chemical structure of the selected compounds plays an important role in this mechanism of heat deposition. There exists an opportunity for the development of alternative gadolinium-based compounds with an order of magnitude longer τ1e in a diluted form to be used as an efficient hyperthermia agent for clinical use. PMID:27341338

  12. Thermal Excitation of Gadolinium-Based Contrast Agents Using Spin Resonance.

    PubMed

    Dinger, Steven C; Fridjhon, Peter; Rubin, David M

    2016-01-01

    Theoretical and experimental investigations into the thermal excitation of liquid paramagnetic contrast agents using the spin resonance relaxation mechanism are presented. The electronic spin-lattice relaxation time τ1e of gadolinium-based contrast agents, which is estimated at 0.1 ns, is ten orders of magnitude faster than the relaxation time of protons in water. The shorter relaxation time is found to significantly increase the rate of thermal energy deposition. To the authors' knowledge this is the first study of gadolinium based contrast agents in a liquid state used as thermal agents. Analysis shows that when τ1e and other experimental parameters are optimally selected, a maximum theoretical heating rate of 29.4 °C.s-1 could be achieved which would suffice for clinical thermal ablation of neoplasms. The experimental results show a statistically significant thermal response for two out of the four contrast agents tested. The results are compared to the simulated estimates via analysis of a detailed model of the system. While these experimentally determined temperature rises are small and thus of no clinical utility, their presence supports the theoretical analysis and strongly suggests that the chemical structure of the selected compounds plays an important role in this mechanism of heat deposition. There exists an opportunity for the development of alternative gadolinium-based compounds with an order of magnitude longer τ1e in a diluted form to be used as an efficient hyperthermia agent for clinical use. PMID:27341338

  13. Effect of gas-containing microspheres and echo contrast agents on free radical formation by ultrasound.

    PubMed

    Kondo, T; Misík, V; Riesz, P

    1998-09-01

    Stabilized microbubbles (microspheres) are widely used to enhance the contrast of ultrasound imaging. Our data provide direct evidence that the contrast agents, Levovist, PVC-AN (polyvinylidene chloride-acrylonitryl copolymer), and Albunex (compared to 5% human albumin), at concentrations comparable to those used for ultrasound imaging, enhance H2O2 production (through the superoxide-dependent pathway) in air-saturated aqueous solutions exposed to 47 kHz ultrasound above the cavitation threshold. These agents also act as scavengers of .H atoms and .OH radicals, thus lowering H2O2 formation (by recombination of .OH radicals) in argon-saturated solutions. EPR spin trapping also reveals that secondary radicals derived from the contrast agents are produced by reactions with .H and .OH which are formed by pyrolysis of water inside cavitation bubbles. In addition, the contrast agents themselves undergo pyrolysis reactions in the cavitation bubbles as demonstrated by formation of methyl radicals. Possible deleterious consequences of the formation of sonochemical intermediates may have to be assessed, particularly since some of the echo contrast agents have been shown to lower the cavitation threshold of diagnostic ultrasound. Unlike the microspheres formed from organic molecules, inorganic microspheres, Eccospheres, because of their stability and inert nature with respect to participation in free radical processes, appear to be suitable tools for enhancing the yields of aqueous sonochemical reactions. PMID:9741598

  14. Main applications of hybrid PET-MRI contrast agents: a review.

    PubMed

    Kiani, A; Esquevin, A; Lepareur, N; Bourguet, P; Le Jeune, F; Gauvrit, Jy

    2016-03-01

    In medical imaging, the continuous quest to improve diagnostic performance and optimize treatment strategies has led to the use of combined imaging modalities. Positron emission tomography (PET) and computed tomography (CT) is a hybrid imaging existing already for many years. The high spatial and contrast resolution of magnetic resonance imaging (MRI) and the high sensitivity and molecular information from PET imaging are leading to the development of this new hybrid imaging along with hybrid contrast agents. To create a hybrid contrast agent for PET-MRI device, a PET radiotracer needs to be combined with an MRI contrast agent. The most common approach is to add a radioactive isotope to the surface of a small superparamagnetic iron oxide (SPIO) particle. The resulting agents offer a wide range of applications, such as pH variation monitoring, non-invasive angiography and early imaging diagnosis of atherosclerosis. Oncology is the most promising field with the detection of sentinel lymph nodes and the targeting of tumor neoangiogenesis. Oncology and cardiovascular imaging are thus major areas of development for hybrid PET-MRI imaging systems and hybrid contrast agents. The aim is to combine high spatial resolution, high sensitivity, morphological and functional information. Future prospects include the use of specific antibodies and hybrid multimodal PET-MRI-ultrasound-fluorescence imaging with the potential to provide overall pre-, intra- and postoperative patient care. Copyright © 2015 John Wiley & Sons, Ltd. PMID:26632007

  15. Connexin 43-targeted T1 contrast agent for MRI diagnosis of glioma.

    PubMed

    Abakumova, Tatiana; Abakumov, Maxim; Shein, Sergey; Chelushkin, Pavel; Bychkov, Dmitry; Mukhin, Vladimir; Yusubalieva, Gaukhar; Grinenko, Nadezhda; Kabanov, Alexander; Nukolova, Natalia; Chekhonin, Vladimir

    2016-01-01

    Glioblastoma multiforme is the most aggressive form of brain tumor. Early and accurate diagnosis of glioma and its borders is an important step for its successful treatment. One of the promising targets for selective visualization of glioma and its margins is connexin 43 (Cx43), which is highly expressed in reactive astrocytes and migrating glioma cells. The purpose of this study was to synthesize a Gd-based contrast agent conjugated with specific antibodies to Cx43 for efficient visualization of glioma C6 in vivo. We have prepared stable nontoxic conjugates of monoclonal antibody to Cx43 and polylysine-DTPA ligands complexed with Gd(III), which are characterized by higher T1 relaxivity (6.5 mM(-1) s(-1) at 7 T) than the commercial agent Magnevist® (3.4 mM(-1) s(-1)). Cellular uptake of Cx43-specific T1 contrast agent in glioma C6 cells was more than four times higher than the nonspecific IgG-contrast agent, as detected by flow cytometry and confocal analysis. MRI experiments showed that the obtained agents could markedly enhance visualization of glioma C6 in vivo after their intravenous administration. Significant accumulation of Cx43-targeted contrast agents in glioma and the peritumoral zone led not only to enhanced contrast but also to improved detection of the tumor periphery. Fluorescence imaging confirmed notable accumulation of Cx43-specific conjugates in the peritumoral zone compared with nonspecific IgG conjugates at 24 h after intravenous injection. All these features of Cx43-targeted contrast agents might be useful for more precise diagnosis of glioma and its borders by MRI. PMID:26265140

  16. The influence of x-ray contrast agents in computed tomography on the induction of dicentrics and γ-H2AX foci in lymphocytes of human blood samples

    NASA Astrophysics Data System (ADS)

    Jost, G.; Golfier, S.; Pietsch, H.; Lengsfeld, P.; Voth, M.; Schmid, T. E.; Eckardt-Schupp, F.; Schmid, E.

    2009-10-01

    The aim of this study was to investigate and quantify two biomarkers for radiation exposure (dicentrics and γ-H2AX foci) in human lymphocytes after CT scans in the presence of an iodinated contrast agent. Blood samples from a healthy donor were exposed to CT scans in the absence or presence of iotrolan 300 at iodine concentrations of 5 or 50 mg ml-1 blood. The samples were exposed to 0.025, 0.05, 0.1 and 1 Gy in a tissue equivalent body phantom. Chromosome aberration scoring and automated microscopic analysis of γ-H2AX foci were performed in parts of the same samples. The theoretical physical dose enhancement factor (DEF) was calculated on the basis of the mass energy-absorption coefficients of iodine and blood and the photon energy spectrum of the CT tube. No significant differences in the yields of dicentrics and γ-H2AX foci were observed in the absence or presence of 5 mg iodine ml-1 blood up to 0.1 Gy, whereas at 1 Gy the yields were elevated for both biomarkers. At an iodine concentration of 50 mg ml-1 serving as a positive control, a biological DEF of 9.5 ± 1.4 and 2.3 ± 0.5 was determined for dicentrics and γ-H2AX foci, respectively. A physical DEF of 1.56 and 6.30 was calculated for 5 and 50 mg iodine ml-1, respectively. Thus, it can be concluded that in the diagnostic dose range (radiation and contrast dose), no relevant biological dose-enhancing effect could be detected, whereas a clear biological dose-enhancing effect could be found for a contrast dose well outside the diagnostic CT range for the complete radiation dose range with both methods.

  17. Poly(Lactic-co-Glycolic) Acid as a Carrier for Imaging Contrast Agents

    PubMed Central

    Doiron, Amber L.; Homan, Kimberly A.; Emelianov, Stanislav; Brannon-Peppas, Lisa

    2010-01-01

    Purpose With the broadening field of nanomedicine poised for future molecular level therapeutics, nano-and microparticles intended for the augmentation of either single- or multimodal imaging are created with PLGA as the chief constituent and carrier. Methods Emulsion techniques were used to encapsulate hydrophilic and hydrophobic imaging contrast agents in PLGA particles. The imaging contrast properties of these PLGA particles were further enhanced by reducing silver onto the PLGA surface, creating a silver cage around the polymeric core. Results The MRI contrast agent Gd-DTPA and the exogenous dye rhodamine 6G were both encapsulated in PLGA and shown to enhance MR and fluorescence contrast, respectively. The silver nanocage built around PLGA nanoparticles exhibited strong near infrared light absorbance properties, making it a suitable contrast agent for optical imaging strategies such as photoacoustic imaging. Conclusions The biodegradable polymer PLGA is an extremely versatile nano- and micro-carrier for several imaging contrast agents with the possibility of targeting diseased states at a molecular level. PMID:19034628

  18. A contrast agent recognizing activated platelets reveals murine cerebral malaria pathology undetectable by conventional MRI.

    PubMed

    von Zur Muhlen, Constantin; Sibson, Nicola R; Peter, Karlheinz; Campbell, Sandra J; Wilainam, Panop; Grau, Georges E; Bode, Christoph; Choudhury, Robin P; Anthony, Daniel C

    2008-03-01

    Human and murine cerebral malaria are associated with elevated levels of cytokines in the brain and adherence of platelets to the microvasculature. Here we demonstrated that the accumulation of platelets in the brain microvasculature can be detected with MRI, using what we believe to be a novel contrast agent, at a time when the pathology is undetectable by conventional MRI. Ligand-induced binding sites (LIBS) on activated platelet glycoprotein IIb/IIIa receptors were detected in the brains of malaria-infected mice 6 days after inoculation with Plasmodium berghei using microparticles of iron oxide (MPIOs) conjugated to a single-chain antibody specific for the LIBS (LIBS-MPIO). No binding of the LIBS-MPIO contrast agent was detected in uninfected animals. A combination of LIBS-MPIO MRI, confocal microscopy, and transmission electron microscopy revealed that the proinflammatory cytokine TNF-alpha, but not IL-1beta or lymphotoxin-alpha (LT-alpha), induced adherence of platelets to cerebrovascular endothelium. Peak platelet adhesion was found 12 h after TNF-alpha injection and was readily detected with LIBS-MPIO contrast-enhanced MRI. Temporal studies revealed that the level of MPIO-induced contrast was proportional to the number of platelets bound. Thus, the LIBS-MPIO contrast agent enabled noninvasive detection of otherwise undetectable cerebral pathology by in vivo MRI before the appearance of clinical disease, highlighting the potential of targeted contrast agents for diagnostic, mechanistic, and therapeutic studies. PMID:18274670

  19. A contrast agent recognizing activated platelets reveals murine cerebral malaria pathology undetectable by conventional MRI

    PubMed Central

    von zur Muhlen, Constantin; Sibson, Nicola R.; Peter, Karlheinz; Campbell, Sandra J.; Wilainam, Panop; Grau, Georges E.; Bode, Christoph; Choudhury, Robin P.; Anthony, Daniel C.

    2008-01-01

    Human and murine cerebral malaria are associated with elevated levels of cytokines in the brain and adherence of platelets to the microvasculature. Here we demonstrated that the accumulation of platelets in the brain microvasculature can be detected with MRI, using what we believe to be a novel contrast agent, at a time when the pathology is undetectable by conventional MRI. Ligand-induced binding sites (LIBS) on activated platelet glycoprotein IIb/IIIa receptors were detected in the brains of malaria-infected mice 6 days after inoculation with Plasmodium berghei using microparticles of iron oxide (MPIOs) conjugated to a single-chain antibody specific for the LIBS (LIBS-MPIO). No binding of the LIBS-MPIO contrast agent was detected in uninfected animals. A combination of LIBS-MPIO MRI, confocal microscopy, and transmission electron microscopy revealed that the proinflammatory cytokine TNF-α, but not IL-1β or lymphotoxin-α (LT-α), induced adherence of platelets to cerebrovascular endothelium. Peak platelet adhesion was found 12 h after TNF-α injection and was readily detected with LIBS-MPIO contrast-enhanced MRI. Temporal studies revealed that the level of MPIO-induced contrast was proportional to the number of platelets bound. Thus, the LIBS-MPIO contrast agent enabled noninvasive detection of otherwise undetectable cerebral pathology by in vivo MRI before the appearance of clinical disease, highlighting the potential of targeted contrast agents for diagnostic, mechanistic, and therapeutic studies. PMID:18274670

  20. The delayed onset of subharmonic and ultraharmonic emissions from a phospholipid-shelled microbubble contrast agent

    PubMed Central

    Shekhar, Himanshu; Awuor, Ivy; Thomas, Keri; Rychak, Joshua J.; Doyley, Marvin M.

    2014-01-01

    Characterizing the nonlinear response of microbubble contrast agents is important for their efficacious use in imaging and therapy. In this paper, we report that the subharmonic and ultraharmonic response of lipid-shelled microbubble contrast agents exhibits a strong temporal dependence. We characterized nonlinear emissions from Targestar-P® microbubbles (Targeson Inc., San Diego, CA, USA) periodically for 60 minutes, at 10 MHz excitation frequency. The results revealed a considerable increase in the subharmonic and ultraharmonic response (nearly 12–15 and 5–8 dB) after 5–10 minutes of agent preparation. However, the fundamental and the harmonic response remained almost unchanged in this period. During the next 50 minutes, the subharmonic, fundamental, ultraharmonic, and harmonic responses decreased steadily by 2–5 dB. The temporal changes in the nonlinear behavior of the agent appeared to be primarily mediated by gas-exchange through the microbubble shell; temperature and prior acoustic excitation based mechanisms were ruled out. Further, there was no measurable change in the agent size distribution by static diffusion. We envisage that these findings will help obtain reproducible measurements from agent characterization, nonlinear imaging, and fluid-pressure sensing. These findings also suggest the possibility for improving nonlinear imaging by careful design of ultrasound contrast agents. PMID:24582298

  1. Anatomical and functional imaging of myocardial infarction in mice using micro-CT and eXIA 160 contrast agent

    PubMed Central

    Ashton, Jeffrey R.; Befera, Nicholas; Clark, Darin; Qi, Yi; Mao, Lan; Rockman, Howard A.; Johnson, G. Allan; Badea, Cristian T.

    2014-01-01

    Non-invasive small animal imaging techniques are essential for evaluation of cardiac disease and potential therapeutics. A novel preclinical iodinated contrast agent called eXIA 160 has recently been developed, which has been evaluated for micro-CT cardiac imaging. eXIA 160 creates strong contrast between blood and tissue immediately after its injection and is subsequently taken up by the myocardium and other metabolically active tissues over time. We focus on these properties of eXIA and show its use in imaging myocardial infarction in mice. Five C57BL/6 mice were imaged ~ 2 weeks after LAD coronary artery ligation. Six C57BL/6 mice were used as controls. Immediately after injection of eXIA 160, an enhancement difference between blood and myocardium of ~340 HU enabled cardiac function estimation via 4D micro-CT scanning with retrospective gating. Four hours post-injection, the healthy perfused myocardium had a contrast difference of ~140 HU relative to blood while the infarcted myocardium showed no enhancement. These differences allowed quantification of infarct size via dual energy micro-CT. In vivo micro-SPECT imaging and ex vivo TTC staining provided validation for the micro-CT findings. Root mean squared error of infarct measurements was 2.7% between micro-CT and SPECT, and 4.7% between micro-CT and TTC. Thus, micro-CT with eXIA 160 can be used to provide both morphological and functional data for preclinical studies evaluating myocardial infarction and potential therapies. Further studies are warranted to study the potential use of eXIA 160 as a CT molecular imaging tool for other metabolically active tissues in the mouse. PMID:24523061

  2. Towards a nanoscale mammographic contrast agent: development of a modular pre-clinical dual optical/x-ray agent

    NASA Astrophysics Data System (ADS)

    Hill, Melissa L.; Gorelikov, Ivan; Niroui, Farnaz; Levitin, Ronald B.; Mainprize, James G.; Yaffe, Martin J.; Rowlands, J. A.; Matsuura, Naomi

    2013-08-01

    Contrast-enhanced digital mammography (CEDM) can provide improved breast cancer detection and characterization compared to conventional mammography by imaging the effects of tumour angiogenesis. Current small-molecule contrast agents used for CEDM are limited by a short plasma half-life and rapid extravasation into tissue interstitial space. To address these limitations, nanoscale agents that can remain intravascular except at sites of tumour angiogenesis can be used. For CEDM, this agent must be both biocompatible and strongly attenuate mammographic energy x-rays. Nanoscale perfluorooctylbromide (PFOB) droplets have good x-ray attenuation and have been used in patients for other applications. However, the macroscopic scale of x-ray imaging (50-100 µm) is inadequate for direct verification that PFOB droplets localize at sites of breast tumour angiogenesis. For efficient pre-clinical optimization for CEDM, we integrated an optical marker into PFOB droplets for microscopic assessment (≪50 µm). To develop PFOB droplets as a new nanoscale mammographic contrast agent, PFOB droplets were labelled with fluorescent quantum dots (QDs). The droplets had mean diameters of 160 nm, fluoresced at 635 nm and attenuated x-ray spectra at 30.5 keV mean energy with a relative attenuation of 5.6 ± 0.3 Hounsfield units (HU) mg-1 mL-1 QD-PFOB. With the agent loaded into tissue phantoms, good correlation between x-ray attenuation and optical fluorescence was found (R2 = 0.96), confirming co-localization of the QDs with PFOB for quantitative assessment using x-ray or optical methods. Furthermore, the QDs can be removed from the PFOB agent without affecting its x-ray attenuation or structural properties for expedited translation of optimized PFOB droplet formulations into patients.

  3. Plasmon-resonant gold nanorods as low backscattering albedo contrast agents for optical coherence tomography.

    PubMed

    Oldenburg, Amy L; Hansen, Matthew N; Zweifel, Daniel A; Wei, Alexander; Boppart, Stephen A

    2006-07-24

    Plasmon-resonant gold nanorods are demonstrated as low backscattering albedo contrast agents for optical coherence tomography (OCT). We define the backscattering albedo, a', as the ratio of the backscattering to extinction coefficient. Contrast agents which modify a' within the host tissue phantoms are detected with greater sensitivity by the differential OCT measurement of both a' and extinction. Optimum sensitivity is achieved by maximizing the difference between contrast agents and tissue, |a'(ca) - a'(tiss)|. Low backscattering albedo gold nanorods (14x 44 nm; lambda(max) = 780 nm) within a high backscattering albedo tissue phantom with an uncertainty in concentration of 20% (randomized 2+/-0.4% intralipid) were readily detected at 82 ppm (by weight) in a regime where extinction alone could not discriminate nanorods. The estimated threshold of detection was 30 ppm. PMID:19516854

  4. Microbubble embedded with upconversion nanoparticles as a bimodal contrast agent for fluorescence and ultrasound imaging

    NASA Astrophysics Data System (ADS)

    Jin, Birui; Lin, Min; You, Minli; Zong, Yujin; Wan, Mingxi; Xu, Feng; Duan, Zhenfeng; Lu, Tianjian

    2015-08-01

    Bimodal imaging offers additional imaging signal thus finds wide spread application in clinical diagnostic imaging. Fluorescence/ultrasound bimodal imaging contrast agent using fluorescent dyes or quantum dots for fluorescence signal has emerged as a promising method, which however requires visible light or UV irradiation resulting in photobleaching, photoblinking, auto-fluorescence and limited tissue penetration depth. To surmount these problems, we developed a novel bimodal contrast agent using layer-by-layer assembly of upconversion nanoparticles onto the surface of microbubbles. The resulting microbubbles with average size of 2 μm provide enhanced ultrasound echo for ultrasound imaging and upconversion emission upon near infrared irradiation for fluorescence imaging. The developed bimodal contrast agent holds great potential to be applied in ultrasound target technique for targeted diseases diagnostics and therapy.

  5. Molecular MR Contrast Agents for the Detection of Cancer: Past and Present

    PubMed Central

    Bogdanov, Alexei; Mazzanti, Mary L.

    2011-01-01

    Magnetic resonance imaging (MRI) is a powerful diagnostic tool capable of providing detailed information about the structure and composition of tumors, with unsurpassed spatial resolution. The use of exogenously administered contrast agents allows compartment-specific enhancement of tumors, enabling imaging of functional blood and interstitial volumes. Current efforts are directed at enhancing the capabilities of MRI in oncology to add contrast agents with molecular specificities to the growing armamentarium of diagnostic probes capable of changing local proton relaxation times as a consequence of specific contrast agent binding to cell surface receptors or extracellular matrix components. We review herein the most notable examples, illustrating major trends in the development of specific probes for high-resolution imaging in molecular oncology. PMID:21362515

  6. A spatially-distributed computational model to quantify behaviour of contrast agents in MR perfusion imaging

    PubMed Central

    Cookson, A.N.; Lee, J.; Michler, C.; Chabiniok, R.; Hyde, E.; Nordsletten, D.; Smith, N.P.

    2014-01-01

    Contrast agent enhanced magnetic resonance (MR) perfusion imaging provides an early, non-invasive indication of defects in the coronary circulation. However, the large variation of contrast agent properties, physiological state and imaging protocols means that optimisation of image acquisition is difficult to achieve. This situation motivates the development of a computational framework that, in turn, enables the efficient mapping of this parameter space to provide valuable information for optimisation of perfusion imaging in the clinical context. For this purpose a single-compartment porous medium model of capillary blood flow is developed which is coupled with a scalar transport model, to characterise the behaviour of both blood-pool and freely-diffusive contrast agents characterised by their ability to diffuse through the capillary wall into the extra-cellular space. A parameter space study is performed on the nondimensionalised equations using a 2D model for both healthy and diseased myocardium, examining the sensitivity of system behaviour to Peclet number, Damköhler number (Da), diffusivity ratio and fluid porosity. Assuming a linear MR signal response model, sample concentration time series data are calculated, and the sensitivity of clinically-relevant properties of these signals to the model parameters is quantified. Both upslope and peak values display significant non-monotonic behaviour with regard to the Damköhler number, with these properties showing a high degree of sensitivity in the parameter range relevant to contrast agents currently in use. However, the results suggest that signal upslope is the more robust and discerning metric for perfusion quantification, in particular for correlating with perfusion defect size. Finally, the results were examined in the context of nonlinear signal response, flow quantification via Fermi deconvolution and perfusion reserve index, which demonstrated that there is no single best set of contrast agent parameters

  7. Numerical Modeling of 3-D Dynamics of Ultrasound Contrast Agent Microbubbles Using the Boundary Integral Method

    NASA Astrophysics Data System (ADS)

    Calvisi, Michael; Manmi, Kawa; Wang, Qianxi

    2014-11-01

    Ultrasound contrast agents (UCAs) are microbubbles stabilized with a shell typically of lipid, polymer, or protein and are emerging as a unique tool for noninvasive therapies ranging from gene delivery to tumor ablation. The nonspherical dynamics of contrast agents are thought to play an important role in both diagnostic and therapeutic applications, for example, causing the emission of subharmonic frequency components and enhancing the uptake of therapeutic agents across cell membranes and tissue interfaces. A three-dimensional model for nonspherical contrast agent dynamics based on the boundary integral method is presented. The effects of the encapsulating shell are approximated by adapting Hoff's model for thin-shell, spherical contrast agents to the nonspherical case. A high-quality mesh of the bubble surface is maintained by implementing a hybrid approach of the Lagrangian method and elastic mesh technique. Numerical analyses for the dynamics of UCAs in an infinite liquid and near a rigid wall are performed in parameter regimes of clinical relevance. The results show that the presence of a coating significantly reduces the oscillation amplitude and period, increases the ultrasound pressure amplitude required to incite jetting, and reduces the jet width and velocity.

  8. Preclinical evaluation of biodegradable macromolecular contrast agents for magnetic resonance imaging

    NASA Astrophysics Data System (ADS)

    Feng, Yi

    Macromolecular contrast agents have been shown to be superior to small molecular weight contrast agents for MRI in blood pool imaging, tumor diagnosis and grading. However, none has been approved by the FDA because they circulate in the bloodstream much longer than small molecular weight contrast agents and result in high tissue accumulation of toxic Gd(III) ions. Biodegradable macromolecular contrast agents (BMCA) were invented to alleviate the toxic accumulation. They have a cleavable disulfide bond based backbone that can be degraded in vivo and excreted out of the body via renal filtration. Furthermore, the side chain of the backbone can be modified to achieve various degradation rates. Three BMCA, (Gd-DTPA)-cystamine copolymers (GDCC), Gd-DTPA cystine copolymers (GDCP), and Gd-DTPA cystine diethyl ester copolymers (GDCEP), were evaluated as blood pool contrast agents in a rat model. They have excellent blood pool enhancement, preferred pharmacokinetics, and only minimal long-term tissue retention of toxic Gd(III) ions. GDCC and GDCP, the lead agents with desired degradation rates, with molecular weights of 20 KDa and 70 KDa, were chosen for dynamic contrast enhanced MRI (DCE-MRI) to differentiate human prostate tumor models of different malignancy and growth rates. GDCC and GDCP could differentiate these tumor models, providing more accurate estimations of plasma volume, flow leakage rate, and permeability surface area product than a small molecular weight contrast agent Gd-DTPA-BMA when compared to the prototype macromolecular contrast agent albumin-Gd-DTPA. GDCC was favored for its neutral charge side chain and reasonable uptake rate by the tumors. GDCC with a molecular weight of 40 KDa (GDCC-40, above the renal filtration cutoff size) was used to assess the efficacy of two photothermal therapies (interstitial and indocyanine green enhanced). GDCC-40 provided excellent tumor enhancement shortly after its injection. Acute tumor response (4 hr) after therapies

  9. Synthesis, Characterization, and in vitro Testing of a Bacteria-Targeted MR Contrast Agent

    PubMed Central

    Matosziuk, Lauren M.; Harney, Allison S.; MacRenaris, Keith W.

    2013-01-01

    A bacteria-targeted MR contrast agent, Zn-1, consisting of two Zn-dipicolylamine (Zn-dpa) groups conjugated to a GdIII chelate has been synthesized and characterized. In vitro studies with S. aureus and E. coli show that Zn-1 exhibits a significant improvement in bacteria labeling efficiency vs. control. Studies with a structural analogue, Zn-2, indicate that removal of one Zn-dpa moiety dramatically reduces the agent's affinity for bacteria. The ability of Zn-1 to significantly reduce the T1 of labeled vs. unlabeled bacteria, resulting in enhanced MR image contrast, demonstrates its potential for visualizing bacterial infections in vivo. PMID:23626484

  10. Brain nuclear magnetic resonance imaging enhanced by a paramagnetic nitroxide contrast agent: preliminary report. [Dogs

    SciTech Connect

    Brasch, R.C.; Nitecki, D.E.; Brant-Zawadzki, M.; Enzmann, D.R.; Wesbey, G.E.; Tozer, T.N.; Tuck, L.D.; Cann, C.E.; Fike, J.R.; Sheldon, P.

    1983-11-01

    Contrast-enhancing agents for demonstrating abnormalities of the blood-brain barrier may extend the diagnostic utility of proton nuclear magnetic resonance (NMR) imaging. TES, a nitroxide stable free radical derivative, was tested as a central nervous system contrast enhancer in dogs with experimentally induced unilateral cerebritis or radiation cerebral damage. After intravenous injection of TES, the normal brain showed no change in NMR appearance, but areas of disease demonstrated a dramatic increase (up to 45%) in spin-echo intensity and a decrease in T/sub 1/, relaxation times. The areas of disease defined by TES enhancement were either not evident on the nonenhanced NMR images or were better defined after contrast administration. In-depth tests of toxicity, stability, and metabolism of this promising NMR contrast agent are now in progress.

  11. Combined ultrasound and photoacoustic imaging of pancreatic cancer using nanocage contrast agents

    NASA Astrophysics Data System (ADS)

    Homan, Kimberly; Shah, Jignesh; Gomez, Sobeyda; Gensler, Heidi; Karpiouk, Andrei; Brannon-Peppas, L.; Emelianov, Stanislav

    2009-02-01

    A new metallodielectric nanoparticle consisting of a silica core and silver outer cage was developed for the purpose of enhancing photoacoustic imaging contrast in pancreatic tissue. These nanocages were injected into an ex vivo porcine pancreas and imaged using a combined photoacoustic and ultrasound (PAUS) assembly. This custom-designed PAUS assembly delivered 800 nm light through a fiber optical light delivery system integrated with 128 element linear array transducer operating at 7.5 MHz center frequency. Imaging results prove that the nanocage contrast agents have the ability to enhance photoacoustic imaging contrast. Furthermore, the value of the combined PAUS imaging modality was demonstrated as the location of nanocages against background native tissue was evident. Future applications of these nanocage contrast agents could include targeting them to pancreatic cancer for enhancement of photoacoustic imaging for diagnosis and therapy.

  12. A self-calibrating PARACEST MRI contrast agent that detects esterase enzyme activity

    PubMed Central

    Li, Yuguo; Sheth, Vipul R.; Liu, Guanshu; Pagel, Mark D.

    2016-01-01

    The CEST effect of many PARACEST MRI contrast agents changes in response to a molecular biomarker. However, other molecular biomarkers or environmental factors can influence CEST, so that a change in CEST is not conclusive proof for detecting the biomarker. To overcome this problem, a second control CEST effect may be included in the same PARACEST agent, which is responsive to all factors that alter the first CEST effect except for the biomarker to be measured. To investigate this approach, a PARACEST MRI contrast agent was developed with one CEST effect that is responsive to esterase enzyme activity and a second control CEST effect. The ratio of the two CEST effects was independent of concentration and T1 relaxation, so that this agent was self-calibrating with respect to these factors. This ratiometric method was dependent on temperature and was influenced by MR coalescence as the chemical exchange rates approached the chemical shifts of the exchangable protons as temperature was increased. The two CEST effects also showed evidence of having different pH dependencies, so that this agent was not self-calibrating with respect to pH. Therefore, a self-calibrating PARACEST MRI contrast agent can more accurately detect a molecular biomarker such as esterase enzyme activity, as long as temperature and pH are within an acceptable physiological range and remain constant. PMID:21861282

  13. Single-walled carbon nanotubes as a multimodal — thermoacoustic and photoacoustic — contrast agent

    PubMed Central

    Pramanik, Manojit; Swierczewska, Magdalena; Green, Danielle; Sitharaman, Balaji; Wang, Lihong V.

    2009-01-01

    We have developed a novel carbon nanotube-based contrast agent for both thermoacoustic and photoacoustic tomography. In comparison with de-ionized water, single-walled carbon nanotubes exhibited more than two-fold signal enhancement for thermoacoustic tomography at 3 GHz. In comparison with blood, they exhibited more than six-fold signal enhancement for photoacoustic tomography at 1064 nm wavelength. The large contrast enhancement of single-walled carbon nanotubes was further corroborated by tissue phantom imaging studies. PMID:19566311

  14. Acoustic characterization and pharmacokinetic analyses of new nanobubble ultrasound contrast agents.

    PubMed

    Wu, Hanping; Rognin, Nicolas G; Krupka, Tianyi M; Solorio, Luis; Yoshiara, Hiroki; Guenette, Gilles; Sanders, Christopher; Kamiyama, Naohisa; Exner, Agata A

    2013-11-01

    In contrast to the clinically used microbubble ultrasound contrast agents, nanoscale bubbles (or nanobubbles) may potentially extravasate into tumors that exhibit more permeable vasculature, facilitating targeted molecular imaging and drug delivery. Our group recently presented a simple strategy using the non-ionic surfactant Pluronic as a size control excipient to produce nanobubbles with a mean diameter of 200 nm that exhibited stability and echogenicity on par with microbubbles. The objective of this study was to carry out an in-depth characterization of nanobubble properties as compared with Definity microbubbles, both in vitro and in vivo. Through use of a tissue-mimicking phantom, in vitro experiments measured the echogenicity of the contrast agent solutions and the contrast agent dissolution rate over time. Nanobubbles were found to be more echogenic than Definity microbubbles at three different harmonic frequencies (8, 6.2 and 3.5 MHz). Definity microbubbles also dissolved 1.67 times faster than nanobubbles. Pharmacokinetic studies were then performed in vivo in a subcutaneous human colorectal adenocarcinoma (LS174T) in mice. The peak enhancement and decay rates of contrast agents after bolus injection in the liver, kidney and tumor were analyzed. No significant differences were observed in peak enhancement between the nanobubble and Definity groups in the three tested regions (tumor, liver and kidney). However, the decay rates of nanobubbles in tumor and kidney were significantly slower than those of Definity in the first 200-s fast initial phase. There were no significant differences in the decay rates in the liver in the initial phase or in three regions of interest in the terminal phase. Our results suggest that the stability and acoustic properties of the new nanobubble contrast agents are superior to those of the clinically used Definity microbubbles. The slower washout of nanobubbles in tumors suggests potential entrapment of the bubbles within

  15. Characterization of novel molecular photoacoustic contrast agents for in vivo photoacoustic tomography

    NASA Astrophysics Data System (ADS)

    Laoui, Samir

    Photoacoustic tomography is a hybrid imaging modality that takes advantage of the high contrast of pure optical imaging and the high intrinsic resolution of ultrasound without the necessity of ionizing radiation. Photoacoustic imaging (PM) is neither purely optical nor purely acoustical in nature, but a combination of the two. It is fundamentally based on light excitation and ultrasonic detection. Photoacoustic imaging has been successful without the introduction of exogenous contrast agents; however, to image deeper regions of biological tissue, a contrast agent is necessary. Several types of photoacoustic contrast agents have been made available for diagnostic purposes; however, the majority of literature has focused on gold nanoparticle systems for which the surface-plasmon resonance effect is important. The only option currently available for molecular PM contrast agents is to choose an existing near infrared absorbing fluorescent probes with the hope that they may generate a substantial photoacoustic (PA) response. However, these dyes have been designed with an optimized fluorescence emission response and are not anticipated to generate an adequate photoacoustic response. This dissertation addresses this lack of precedence in the literature for understanding the mechanism of a photoacoustic signal generation from strongly absorbing dye molecules including BODIPY, cyanine and curcumin systems. This work represents preliminary efforts in bringing novel molecular photoacoustic contrast agents (MPACs) into the photoacoustic imaging arena. To this end, photoacoustic and optical Z-scan experiments, and quenching studies were employed to demonstrate correlation of photoacoustic emission enhancement with excited state absorption mechanisms. To investigate further the photoacoustic emission in a practical imaging setting, MPACs were imaged using a recently developed photoacoustic imaging tomography system which was constructed exclusively for the purpose of this study.

  16. ACOUSTIC CHARACTERIZATION AND PHARAMACOKINETIC ANALYSES OF NEW NANOBUBBLE ULTRASOUND CONTRAST AGENTS

    PubMed Central

    Wu, Hanping; Rognin, Nicolas G.; Krupka, Tianyi M.; Solorio, Luis; Yoshiara, Hiroki; Guenette, Gilles; Sanders, Christoher; Kamiyama, Naohisa; Exner, Agata A.

    2013-01-01

    In contrast to the clinically used microbubble ultrasound contrast agents, nanoscale bubbles (or nanobubbles) may potentially extravasate into tumors that exhibit more permeable vasculature, facilitating targeted molecular imaging and drug delivery. Our group recently presented a simple strategy using the non-ionic surfactant Pluronic as a size control excipient to produce nanobubbles with a mean diameter of 200 nm that exhibited stability and echogenicity on par with microbubbles. The objective of this study was to carry out an in-depth characterization of nanobubble properties as compared with Definity microbubbles, both in vitro and in vivo. Through use of a tissue-mimicking phantom, in vitro experiments measured the echogenicity of the contrast agent solutions and the contrast agent dissolution rate over time. Nanobubbles were found to be more echogenic than Definity microbubbles at three different harmonic frequencies (8, 6.2 and 3.5 MHz). Definity microbubbles also dissolved 1.67 times faster than nanobubbles. Pharmacokinetic studies were then performed in vivo in a subcutaneous human colorectal adenocarcinoma (LS174T) in mice. The peak enhancement and decay rates of contrast agents after bolus injection in the liver, kidney and tumor were analyzed. No significant differences were observed in peak enhancement between the nanobubble and Definity groups in the three tested regions (tumor, liver and kidney). However, the decay rates of nanobubbles in tumor and kidney were significantly slower than those of Definity in the first 200-s fast initial phase. There were no significant differences in the decay rate in the liver in the initial phase or in three regions of interest in the terminal phase. Our results suggest that the stability and acoustic properties of the new nanobubble contrast agents are superior to those of the clinically used Definity microbubbles. The slower washout of nanobubbles in tumors suggests potential entrapment of the bubbles within the

  17. Specific binding of molecularly targeted agents to pancreas tumors and impact on observed optical contrast

    NASA Astrophysics Data System (ADS)

    Samkoe, Kimberley S.; Hextrum, Shannon K.; Pardesi, Omar; O'Hara, Julia A.; Hasan, Tayyaba; Pogue, Brian W.

    2010-02-01

    In optical imaging it is thought that optimum tumor contrast can be achieved with the use of small-labeled molecular tracers that have high affinity to their targets and fast clearance rates from the blood stream and healthy tissues. An example of this is fluorescently tagged EGF to monitor the molecular activity of tumors, such as pancreatic cancer. Extensive fluorescence contrast analysis for fluorescence molecular tomography has been performed on the AsPC-1 pancreas tumor, grown orthotopically in mice; yet, the binding dynamics of the EGF-fluorescent agent in vivo is not completely known. The bulk pancreatic tumor displays 3:1 contrast relative to the normal pancreas at long times after injection; however, even higher levels of fluorescence in the liver, kidney and intestine suggest that molecular specificity for the tumor may be low. Mice were administered a fluorescently labeled EGF agent and were sacrificed at various time points post-injection. To analyze the amount of specific binding at each time point frozen tissue samples were fluorescently imaged, washed with saline to remove the interstitially distributed contrast agent, and then imaged again. This technique demonstrated that approximately ~10% of the molecular target was firmly bound to the cell, while 90% was mobile or unbound. This low binding ratio suggests that the contrast observed is from inherent properties of the tumor (i.e. enhanced permeability and retention effect) and not from specific bound contrast as previously anticipated. The use of EGF contrast agents in MRI-guided fluorescence tomography and the impact of low binding specificity are discussed.

  18. Contrast agents and ionization with respect to safety for patients and doctors.

    PubMed

    von Tengg-Kobligk, Hendrik; Kara, Levent; Klink, Thorsten; Khanicheh, Elham; Heverhagen, Johannes T; Böhm, Ingrid B

    2015-01-01

    In hemodialysis patients, radiographic imaging with iodinated contrast medium (ICM) application plays a central role in the diagnosis and/or follow-up of disease-related conditions. Therefore, safety aspects concerning ICM administration and radiation exposure have a great impact on this group of patients. Current hardware and software improvements including the design and synthesis of modern contrast compounds allow the use of very small amounts of ICM in concert with low radiation exposure. Undesirable ICM side effects are divided into type A (predictable reactions such as heat feeling, headache, and contrast-induced acute kidney injury, for example) and type B (nonpredictable or hypersensitivity) reactions; this chapter deals with the latter. The first onset cannot be prevented. To prevent hypersensitivity upon reexposure of ICM, an allergological workup is recommended. If this is not possible and ICM is necessary, the patient should receive a premedication (H1 antihistamine with or without corticosteroids). Current imaging hardware and software improvements (e.g. such as additional filtration of the X-ray beam) allow the use of very small amount of ICM and small X-ray doses. Proper communication among the team involved in the treatment of a patient may allow to apply imaging protocols and efficient imaging strategies limiting radiation exposure to a minimum. Practical recommendations will guide the reader how to use radiation and ICM efficiently to improve both patient and staff safety. PMID:25676292

  19. Functional Hyperbranched Polylysine as Potential Contrast Agent Probes for Magnetic Resonance Imaging.

    PubMed

    Zu, Guangyue; Liu, Min; Zhang, Kunchi; Hong, Shanni; Dong, Jingjin; Cao, Yi; Jiang, Bin; Luo, Liqiang; Pei, Renjun

    2016-06-13

    Researchers have never stopped questing contrast agents with high resolution and safety to overcome the drawbacks of small-molecule contrast agents in clinic. Herein, we reported the synthesis of gadolinium-based hyperbranched polylysine (HBPLL-DTPA-Gd), which was prepared by thermal polymerization of l-lysine via one-step polycondensation. After conjugating with folic acid, its potential application as MRI contrast agent was then evaluated. This contrast agent had no obvious cytotoxicity as verified by WST assay and H&E analysis. Compared to Gd(III)-diethylenetriaminepentaacetic acid (Gd-DTPA) (r1 = 4.3 mM(-1) s(-1)), the FA-HBPLL-DTPA-Gd exhibited much higher longitudinal relaxivity value (r1 = 13.44 mM(-1) s(-1)), up to 3 times higher than Gd-DTPA. The FA-HBPLL-DTPA-Gd showed significant signal intensity enhancement in the tumor region at various time points and provided a long time window for MR examination. The results illustrate that FA-HBPLL-DTPA-Gd will be a potential candidate for tumor-targeted MRI. PMID:27187578

  20. A potentially artifact-free oral contrast agent for gastrointestinal MRI.

    PubMed

    Liebig, T; Stoupis, C; Ros, P R; Ballinger, J R; Briggs, R W

    1993-11-01

    The combination of diamagnetic barium sulfate and superparamagnetic iron oxide (SPIO) in one suspension produces a macroscopic cancellation of positive and negative magnetic susceptibility components that can potentially eliminate susceptibility artifacts even with gradient echo pulse sequences. The relaxation properties that make the SPIO suspension a useful negative contrast agent are retained. PMID:8259066

  1. MRI contrast agent delivery using spore capsules: controlled release in blood plasma.

    PubMed

    Lorch, Mark; Thomasson, Matthew J; Diego-Taboada, Alberto; Barrier, Sylvain; Atkin, Stephen L; Mackenzie, Grahame; Archibald, Stephen J

    2009-11-14

    The exine coatings of spores can be used to encapsulate drug molecules. We have demonstrated that these microcapsules can be filled with a commercial gadolinium(III) MRI contrast agent (in this proof of concept study Gd-DTPA-BMA was used) which is slowly released in plasma due to enzymatic digestion of the capsule. PMID:19841803

  2. Gold-coated iron oxide nanoparticles as a T2 contrast agent in magnetic resonance imaging.

    PubMed

    Ahmad, Tanveer; Bae, Hongsub; Rhee, Ilsu; Chang, Yongmin; Jin, Seong-Uk; Hong, Sungwook

    2012-07-01

    Gold-coated iron oxide (Fe3O4) nanoparticles were synthesized for use as a T2 contrast agent in magnetic resonance imaging (MRI). The coated nanoparticles were spherical in shape with an average diameter of 20 nm. The gold shell was about 2 nm thick. The bonding status of the gold on the nanoparticle surfaces was checked using a Fourier transform infrared spectrometer (FTIR). The FTIR spectra confirmed the attachment of homocysteine, in the form of thiolates, to the Au shell of the Au-Fe3O4 nanoparticles. The relaxivity ratio, R2/R1, for the coated nanoparticles was 3-fold higher than that of a commercial contrast agent, Resovist, which showed the potential for their use as a T2 contrast agent with high efficacy. In animal experiments, the presence of the nanoparticles in rat liver resulted in a 71% decrease in signal intensity in T2-weighted MR images, indicating that our gold-coated iron oxide nanoparticles are suitable for use as a T2 contrast agent in MRI. PMID:22966533

  3. Hypoxia targeted carbon nanotubes as a sensitive contrast agent for photoacoustic imaging of tumors

    NASA Astrophysics Data System (ADS)

    Zanganeh, Saeid; Aguirre, Andres; Biswal, Nrusingh C.; Pavlik, Christopher; Smith, Michael B.; Alqasemi, Umar; Li, Hai; Zhu, Quing

    2011-03-01

    Development of new and efficient contrast agents is of fundamental importance to improve detection sensitivity of smaller lesions. Within the family of nanomaterials, carbon nanotubes (CNT) not only have emerged as a new alternative and efficient transporter and translocater of therapeutic molecules but also as a photoacoustic molecular imaging agent owing to its strong optical absorption in the near-infrared region. Drugs, Antibodies and nucleic acids could functionalize the CNT and prepare an appropriate system for delivering the cargos to cells and organs. In this work, we present a novel photoacoustic contrast agent which is based on a unique hypoxic marker in the near infrared region, 2-nitroimidazole -bis carboxylic acid derivative of Indocyanine Green conjugated to single walled carbon nanotube (SWCNT-2nitroimidazole-ICG). The 2-nitroimidazole-ICG has an absorption peak at 755 nm and an extinction coefficient of 20,5222 M-1cm-1. The conjugation of this marker with SWCNT shows more than 25 times enhancement of optical absorption of carbon nanotubes in the near infrared region. This new conjugate has been optically evaluated and shows promising results for high contrast photoacoustic imaging of deeply located tumors. The conjugate specifically targets tumor hypoxia, an important indicator of tumor metabolism and tumor therapeutic response. The detection sensitivity of the new contrast agent has been evaluated in-vitro cell lines and with in-vivo tumors in mice.

  4. Azoimidazole functionalized Ni-porphyrins for molecular spin switching and light responsive MRI contrast agents.

    PubMed

    Heitmann, Gernot; Schütt, Christian; Gröbner, Jens; Huber, Lukas; Herges, Rainer

    2016-07-28

    Azo-N-methylimidazole functionalized Ni(ii)porphyrins were rationally designed and synthesized and their performance as molecular spin switches was investigated. They perform intramolecular light-driven coordination-induced spin state switching (LD-CISSS) in the presence of water and therefore are an important step towards spin switches for medicinal applications, particularly functional MRI contrast agents. PMID:27334263

  5. Counterbalancing the use of ultrasound contrast agents by a cavitation-regulated system.

    PubMed

    Desjouy, C; Fouqueray, M; Lo, C W; Muleki Seya, P; Lee, J L; Bera, J C; Chen, W S; Inserra, C

    2015-09-01

    The stochastic behavior of cavitation can lead to major problems of initiation and maintenance of cavitation during sonication, responsible of poor reproducibility of US-induced bioeffects in the context of sonoporation for instance. To overcome these disadvantages, the injection of ultrasound contrast agents as cavitation nuclei ensures fast initiation and lower acoustic intensities required for cavitation activity. More recently, regulated-cavitation devices based on the real-time modulation of the applied acoustic intensity have shown their potential to maintain a stable cavitation state during an ultrasonic shot, in continuous or pulsed wave conditions. In this paper is investigated the interest, in terms of cavitation activity, of using such regulated-cavitation device or injecting ultrasound contrast agents in the sonicated medium. When using fixed applied acoustic intensity, results showed that introducing ultrasound contrast agents increases reproducibility of cavitation activity (coefficient of variation 62% and 22% without and with UCA, respectively). Moreover, the use of the regulated-cavitation device ensures a given cavitation activity (coefficient of variation less 0.4% in presence of UCAs or not). This highlights the interest of controlling cavitation over time to free cavitation-based application from the use of UCAs. Interestingly, during a one minute sonication, while ultrasound contrast agents progressively disappear, the regulated-cavitation device counterbalance their destruction to sustain a stable inertial cavitation activity. PMID:25682465

  6. Dynamic assessment of the focal hepatic lesion in rats using ultrasonic contrast agent.

    PubMed

    Zhang, Chao; Deng, Youbin; Huang, Daozhong; Zhang, Qingping

    2006-01-01

    The focal hepatic lesion caused by local injection of absolute alcohol in rats was evaluated with ultrasonic contrast agent and pathologic examination. Twenty adult Wistar rats weighing about 200 g were injected with absolute alcohol (0.05-0.1 mL each one) on the exterior left lobe of the liver under the monitoring of ultrasound. Pulse inversion harmonic imaging was used to evaluate the focal lesion after bolus injection of ultrasonic contrast agent (0.05 mL/200 g) through caudal vein. Seven days later, the focal lesion was studied again as before. The exterior left lobe of liver with focal lesion was incised and underwent pathologic examination. The results showed that all of the focal lesions could be defined clearly after bolus injection of the ultrasonic contrast agent under the mode of pulse inversion harmonic imaging. There was good correlation between the size of the focal lesion measured by ultrasound on the 7th day after the "ablation" under the mode of pulse inversion harmonic imaging and that gotten by pathologic examination (P = 0.39). The focus size measured by ultrasound right after the ablation was larger than that gotten by pathologic examination (P = 0.002). It was concluded that ultrasonic contrast agent plus pulse inversion harmonic imaging could be used to assess the size of the focal hepatic lesion caused by local injection of absolute alcohol in rats. PMID:16961285

  7. Mechanistic studies of Gd3+-based MRI contrast agents for Zn2+ detection: towards rational design.

    PubMed

    Bonnet, Célia S; Caillé, Fabien; Pallier, Agnès; Morfin, Jean-François; Petoud, Stéphane; Suzenet, Franck; Tóth, Éva

    2014-08-25

    A series of novel pyridine-based Gd(3+) complexes have been prepared and studied as potential MRI contrast agents for Zn(2+) detection. By independent assessment of molecular parameters affecting relaxivity, we could interpret the relaxivity changes observed upon Zn(2+) binding in terms of variations of the rotational motion. PMID:25116889

  8. Prolonged in vivo circulation time by zwitterionic modification of magnetite nanoparticles for blood pool contrast agents.

    PubMed

    Xiao, Wangchuan; Lin, Jiang; Li, Mingli; Ma, Yongjie; Chen, Yuxin; Zhang, Chunfu; Li, Dan; Gu, Hongchen

    2012-01-01

    Long circulation time is critical for blood pool contrast agents used in high-resolution magnetic resonance angiography. For iron oxide particle contrast agents, size and surface properties significantly influence their in vivo performance. We developed a novel long-circulating blood pool contrast agent by introducing zwitterionic structure onto the particle surface. Zwitterionic structure was fabricated by 3-(diethylamino)propylamine (DEAPA) grafted onto the surface of ployacrylic acid coated magnetite nanoparticles via EDC/NHS [N-(3-dimethylaminopropyl)-N'-ethylcarbo-diimide hydrochloride/N-hydroxysuccinimide] coupling chemistry. Zwitterionic particles demonstrated five times lower macrophage cell uptake than the original particles and low cell toxicity. Magnetic resonance angiography indicated that zwitterionic nanoparticles had much longer in vivo circulation time than the original particles and were an ideal candidate for blood pool contrast agent. We suppose that zwitterionic modification by DEAPA and EDC/NHS can be used generally for coating nanoparticles with carboxyl surface and to prolong their circulating time. PMID:22539402

  9. Evaluation of a targeted nanobubble ultrasound contrast agent for potential tumor imaging

    NASA Astrophysics Data System (ADS)

    Li, Chunfang; Shen, Chunxu; Liu, Haijuan; Wu, Kaizhi; Zhou, Qibing; Ding, Mingyue

    2015-03-01

    Targeted nanobubbles have been reported to improve the contrast effect of ultrasound imaging due to the enhanced permeation and retention effects at tumor vascular leaks. In this work, the contrast enhancement abilities and the tumor targeting potential of a self-made VEGFR2-targeted nanobubble ultrasound contrast agent was evaluated in-vitro and in-vivo. Size distribution and zeta potential were assessed. Then the contrast-enhanced ultrasound imaging of the VEGFR2 targeted nanobubbles were evaluated with a custom-made experimental apparatus and in normal Wistar rats. Finally, the in-vivo tumor-targeting ability was evaluated on nude mice with subcutaneous tumor. The results showed that the target nanobubbles had uniform distribution with the average diameter of 208.1 nm, polydispersity index (PDI) of 0.411, and zeta potential of -13.21 mV. Significant contrast enhancement was observed in both in-vitro and in-vivo ultrasound imaging, demonstrating that the self-made target nanobubbles can enhance the contrast effect of ultrasound imaging efficiently. Targeted tumor imaging showed less promising result, due to the fact that the targeted nanobubbles arriving and permeating through tumor vessels were not many enough to produce significant enhancement. Future work will focus on exploring new imaging algorithm which is sensitive to targeted nanobubbles, so as to correctly detect the contrast agent, particularly at a low bubble concentration.

  10. Alk5 inhibition increases delivery of macromolecular and protein-bound contrast agents to tumors

    PubMed Central

    Daldrup-Link, Heike E.; Mohanty, Suchismita; Ansari, Celina; Lenkov, Olga; Shaw, Aubie; Ito, Ken; Hong, Su Hyun; Hoffmann, Matthias; Pisani, Laura; Boudreau, Nancy; Gambhir, Sanjiv Sam; Coussens, Lisa M.

    2016-01-01

    Limited transendothelial permeability across tumor microvessels represents a significant bottleneck in the development of tumor-specific diagnostic agents and theranostic drugs. Here, we show an approach to increase transendothelial permeability of macromolecular and nanoparticle-based contrast agents via inhibition of the type I TGF-β receptor, activin-like kinase 5 (Alk5), in tumors. Alk5 inhibition significantly increased tumor contrast agent delivery and enhancement on imaging studies, while healthy organs remained relatively unaffected. Imaging data correlated with significantly decreased tumor interstitial fluid pressure, while tumor vascular density remained unchanged. This immediately clinically translatable concept involving Alk5 inhibitor pretreatment prior to an imaging study could be leveraged for improved tumor delivery of macromolecular and nanoparticle-based imaging probes and, thereby, facilitate development of more sensitive imaging tests for cancer diagnosis, enhanced tumor characterization, and personalized, image-guided therapies. PMID:27182558

  11. Preparation of near-infrared-labeled targeted contrast agents for clinical translation

    NASA Astrophysics Data System (ADS)

    Olive, D. Michael

    2011-03-01

    Targeted fluorophore-labeled contrast agents are moving toward translation to human surgical use. To prepare for future clinical use, we examined the performance of potential ligands targeting the epidermal growth factor receptor, α5β3 integrins, and GLUT transporters for their suitability as directed contrast agents. Each agent was labeled with IRDye 800CW, and near-infrared dye with excitation/emission wavelengths of 789/805 nm, which we determined had favorable toxicity characteristics. The probe molecules examined consisted of Affibodies, nanobodies, peptides, and the sugar 2-deoxy-D-glucose. Each probe was tested for specific and non-specific binding in cell based assays. All probe types showed good performance in mouse models for detecting either spontaneous tumors or tumor xenografts in vivo. Each of the probes tested show promise for future human clinical studies.

  12. Development of nanostars as a biocompatible tumor contrast agent: toward in vivo SERS imaging.

    PubMed

    D'Hollander, Antoine; Mathieu, Evelien; Jans, Hilde; Vande Velde, Greetje; Stakenborg, Tim; Van Dorpe, Pol; Himmelreich, Uwe; Lagae, Liesbet

    2016-01-01

    The need for sensitive imaging techniques to detect tumor cells is an important issue in cancer diagnosis and therapy. Surface-enhanced Raman scattering (SERS), realized by chemisorption of compounds suitable for Raman spectroscopy onto gold nanoparticles, is a new method for detecting a tumor. As a proof of concept, we studied the use of biocompatible gold nanostars as sensitive SERS contrast agents targeting an ovarian cancer cell line (SKOV3). Due to a high intracellular uptake of gold nanostars after 6 hours of exposure, they could be detected and located with SERS. Using these nanostars for passive targeting after systemic injection in a xenograft mouse model, a detectable signal was measured in the tumor and liver in vivo. These signals were confirmed by ex vivo SERS measurements and darkfield microscopy. In this study, we established SERS nanostars as a highly sensitive contrast agent for tumor detection, which opens the potential for their use as a theranostic agent against cancer. PMID:27536107

  13. Small animal imaging platform for quantitative assessment of short-wave infrared-emitting contrast agents

    NASA Astrophysics Data System (ADS)

    Hu, Philip; Mingozzi, Marco; Higgins, Laura M.; Ganapathy, Vidya; Zevon, Margot; Riman, Richard E.; Roth, Charles M.; Moghe, Prabhas V.; Pierce, Mark C.

    2015-03-01

    We report the design, calibration, and testing of a pre-clinical small animal imaging platform for use with short-wave infrared (SWIR) emitting contrast agents. Unlike materials emitting at visible or near-infrared wavelengths, SWIR-emitting agents require detection systems with sensitivity in the 1-2 μm wavelength region, beyond the range of commercially available small animal imagers. We used a collimated 980 nm laser beam to excite rare-earth-doped NaYF4:Er,Yb nanocomposites, as an example of a SWIR emitting material under development for biomedical imaging applications. This beam was raster scanned across the animal, with fluorescence in the 1550 nm wavelength region detected by an InGaAs area camera. Background adjustment and intensity non-uniformity corrections were applied in software. The final SWIR fluorescence image was overlaid onto a standard white-light image for registration of contrast agent uptake with respect to anatomical features.

  14. Development of nanostars as a biocompatible tumor contrast agent: toward in vivo SERS imaging

    PubMed Central

    D’Hollander, Antoine; Mathieu, Evelien; Jans, Hilde; Vande Velde, Greetje; Stakenborg, Tim; Van Dorpe, Pol; Himmelreich, Uwe; Lagae, Liesbet

    2016-01-01

    The need for sensitive imaging techniques to detect tumor cells is an important issue in cancer diagnosis and therapy. Surface-enhanced Raman scattering (SERS), realized by chemisorption of compounds suitable for Raman spectroscopy onto gold nanoparticles, is a new method for detecting a tumor. As a proof of concept, we studied the use of biocompatible gold nanostars as sensitive SERS contrast agents targeting an ovarian cancer cell line (SKOV3). Due to a high intracellular uptake of gold nanostars after 6 hours of exposure, they could be detected and located with SERS. Using these nanostars for passive targeting after systemic injection in a xenograft mouse model, a detectable signal was measured in the tumor and liver in vivo. These signals were confirmed by ex vivo SERS measurements and darkfield microscopy. In this study, we established SERS nanostars as a highly sensitive contrast agent for tumor detection, which opens the potential for their use as a theranostic agent against cancer. PMID:27536107

  15. Iodine-125-labeled cRGD-gold nanoparticles as tumor-targeted radiosensitizer and imaging agent

    NASA Astrophysics Data System (ADS)

    Su, Ning; Dang, Yajie; Liang, Guangli; Liu, Guizhi

    2015-04-01

    Research interests on radiosensitive property of gold nanoparticles (GNPs) are rapidly raised because of the extensively proved in vitro effectiveness and clinical necessity. However, the issue of targeted accumulation of GNPs in tumor tissues hindered the transference to in vivo applications. In this study, hybrid nano-sized cyclic Arg-Gly-Asp-conjugated GNPs (cRGD-GNPs) integrated with radioactive iodine-125 was fabricated as tumor-targeted radiosensitizer. Therapeutic effects, including acute apoptosis (2 days post treatment) and long-term influence (up to 21 days), were investigated on NCI-H446 tumor-bearing mice via Tc-99 m-Annexin V SPECT and volume measurements, respectively. Apoptosis and volume loss were consistent in showing that tumor growth was effectively suppressed via the treatment of 125I-cRGD-GNP sensitized radiotherapy (RT), a more significantly radiosensitive effect than the treatment of non-targeted GNPs with RT, RT treatment alone, and no treatment. SPECT/CT images showed that the uptake of cRGD-GNPs by tumor tissues reached the peak target/non-target value of 4.76 at around 2 h post injection, and dynamic radioactivity monitoring showed that 125I-cRGD-GNPs maintained about 2.5% of injected dosage at 55 h post injection. For long-term influence, a significant radiosensitized RT-induced volume loss was observed. Hence, cyclic RGD conjugation makes the GNP-based radiosensitizer tumor targeting, offering a new modality for enhancing radiotherapeutic efficacy. Additionally, the introduction of I-125 serves as both a therapeutic factor and a radiotracer for in vivo tracking of GNPs.

  16. Pineapple juice as a negative oral contrast agent in magnetic resonance cholangiopancreatography: a preliminary evaluation.

    PubMed

    Riordan, R D; Khonsari, M; Jeffries, J; Maskell, G F; Cook, P G

    2004-12-01

    The quality of magnetic resonance cholangiopancreatography (MRCP) images is frequently degraded by high signal from the gastrointestinal tract. The aim of this study is to evaluate pineapple juice (PJ) as an oral negative contrast agent in MRCP. Preliminary in vitro evaluation demonstrated that PJ shortened T(2) relaxation time and hence decreased T(2) signal intensity on a standard MRCP sequence to a similar degree to a commercially available negative contrast agent (ferumoxsil). Electrothermal atomic absorption spectrometry assay demonstrated a high manganese concentration in PJ of 2.76 mg dl(-1), which is likely to be responsible for its T(2) imaging properties. MRCP was subsequently performed in 10 healthy volunteers, before and at 15 min and 30 min following ingestion of 400 ml of PJ. Images were assessed blindly by two Consultant Radiologists using a standard grading technique based on contrast effect (degree of suppression of bowel signal), and image effect (diagnostic quality). There were statistically significant improvements in contrast and image effect between pre and post PJ images. There was particularly significant improvement in visualization of the pancreatic duct, but no significant difference between 15 min and 30 min post PJ images. Visualization of the ampulla, common bile duct, common hepatic and central intrahepatic ducts were also significantly improved at 15 min following PJ. Our results demonstrate that PJ, may be used as an alternative to commercially available negative oral contrast agent in MRCP. PMID:15569640

  17. Comparison of the optoacoustic signal generation efficiency of different nanoparticular contrast agents.

    PubMed

    Bost, Wolfgang; Lemor, Robert; Fournelle, Marc

    2012-11-20

    Optoacoustic imaging represents a new modality that allows noninvasive in vivo molecular imaging with optical contrast and acoustical resolution. Whereas structural or functional imaging applications such as imaging of vasculature do not require contrast enhancing agents, nanoprobes with defined biochemical binding behavior are needed for molecular imaging tasks. Since the contrast of this modality is based on the local optical absorption coefficient, all particle or molecule types that show significant absorption cross sections in the spectral range of the laser wavelength used for signal generation are suitable contrast agents. Currently, several particle types such as gold nanospheres, nanoshells, nanorods, or polymer particles are used as optoacoustic contrast agents. These particles have specific advantages with respect to their absorption properties, or in terms of biologically relevant features (biodegradability, binding to molecular markers). In the present study, a comparative analysis of the signal generation efficiency of gold nanorods, polymeric particles, and magnetite particles using a 1064 nm Nd:YAG laser for signal generation is described. PMID:23207315

  18. Stable Encapsulation of Air in Mesoporous Silica Nanoparticles: Fluorocarbon-Free Nanoscale Ultrasound Contrast Agents.

    PubMed

    Yildirim, Adem; Chattaraj, Rajarshi; Blum, Nicholas T; Goldscheitter, Galen M; Goodwin, Andrew P

    2016-06-01

    While gas-filled micrometer-sized ultrasound contrast agents vastly improve signal-to-noise ratios, microbubbles have short circulation lifetimes and poor extravasation from the blood. Previously reported fluorocarbon-based nanoscale contrast agents are more stable but their contrast is generally lower owing to their size and dispersity. The contrast agents reported here are composed of silica nanoparticles of ≈100 nm diameter that are filled with ≈3 nm columnar mesopores. Functionalization of the silica surface with octyl groups and resuspension with Pluronic F127 create particles with pores that remain filled with air but are stable in buffer and serum. Administration of high intensity focused ultrasound (HIFU) allows sensitive imaging of the silica nanoparticles down to 10(10) particles mL(-1) , with continuous imaging for at least 20 min. Control experiments with different silica particles supported the hypothesis that entrapped air could be pulled into bubble nuclei, which can then in turn act as acoustic scatterers. This process results in very little hemolysis in whole blood, indicating potential for nontoxic blood pool imaging. Finally, the particles are lyophilized and reconstituted or stored in PBS (phosphate-buffered saline, at least for four months) with no loss in contrast, indicating stability to storage and reformulation. PMID:26990167

  19. Acute adverse reactions to radiographic iodinated and gadolinium-based contrast media: incidence, risk factors and premedication: from published evidence to a practical approach.

    PubMed

    Tonolini, M; Bianco, R

    2011-01-01

    Although relatively uncommon especially in their severe manifestations, adverse reactions (ARs) to radiographic contrast media (CM) may represent a source of concern to both physicians and patients because of the large number of CT and MR imaging procedures daily performed. In this paper the current literature is reviewed regarding incidence and risk factors for acute ARs to both iodinated and gadolinium-based CM, and about the usefulness of pharmacological premedication to reduce risk. A practical approach for everyday clinical practice is proposed. PMID:22262334

  20. Gadolinium-containing MRI contrast agents: important variations on a theme for NSF.

    PubMed

    Kuo, Phillip H

    2008-01-01

    Millions of doses of gadolinium-based contrast agents (GBCAs) are administered annually to improve the clinical utility of magnetic resonance imaging. All the approved agents incorporate one atom of the rare earth metal gadolinium into a chelate to improve the safety of the ordinarily toxic free gadolinium. The undeniable epidemiologic link between GBCAs and nephrogenic systemic fibrosis (NSF) has prompted renewed investigation into the different chemical properties of the GBCAs despite their clinical interchangeability. Gadolinium-based contrast agents can be divided into different categories: linear versus macrocyclic structure, ionic versus nonionic, and non-protein-binding versus protein-binding agents. The GBCAs differ significantly with respect to transmetallation and kinetic and thermodynamic stability and therefore their propensity to release free gadolinium, which is hypothesized to induce NSF. That gadodiamide, with its susceptibility to transmetallation and relatively low thermodynamic and kinetic stability, is associated with the most cases of NSF supports this hypothesis. On the other hand, the greater stability of a macrocyclic agent hypothetically would confer a greater safety margin with regard to NSF. Because few published data on an experimental model of NSF exist, continuing vigilance is necessary to report new cases of NSF, especially with regard to the agents with small market share. PMID:18180006

  1. Amphiphilic polymer-coated hybrid nanoparticles as CT/MRI dual contrast agents

    NASA Astrophysics Data System (ADS)

    Kim, Dongkyu; Yu, Mi Kyung; Lee, Tae Sup; Park, Jae Jun; Jeong, Yong Yeon; Jon, Sangyong

    2011-04-01

    We describe hybrid nanoparticles, composed of iron oxide and gold nanoparticles, as potential dual contrast agents for both computed tomography (CT) and magnetic resonance imaging (MRI). The hybrid nanoparticles are synthesized by thermal decomposition of mixtures of Fe-oleate and Au-oleylamine complexes. Using a nano-emulsion method, the nanoparticles are coated with amphiphilic poly(DMA-r-mPEGMA-r-MA) to impart water-dispersity and antibiofouling properties. An in vitro phantom study shows that the hybrid nanoparticles have high CT attenuation, because of the constituent gold nanoparticles, and afford a good MR signal, attributable to the contained iron oxide nanoparticles. Intravenous injection of the hybrid nanoparticles into hepatoma-bearing mice results in high contrast between the hepatoma and normal hepatic parenchyma in both CT and MRI. These results suggest that the hybrid nanoparticles may be useful as CT/MRI dual contrast agents for in vivo hepatoma imaging.

  2. Synthesis of nanoparticle CT contrast agents: in vitro and in vivo studies

    NASA Astrophysics Data System (ADS)

    Kim, Sung June; Xu, Wenlong; Wasi Ahmad, Md; Baeck, Jong Su; Chang, Yongmin; Bae, Ji Eun; Chae, Kwon Seok; Kim, Tae Jeong; Park, Ji Ae; Lee, Gang Ho

    2015-10-01

    Water-soluble and biocompatible D-glucuronic acid coated Na2WO4 and BaCO3 nanoparticles were synthesized for the first time to be used as x-ray computed tomography (CT) contrast agents. Their average particle diameters were 3.2 ± 0.1 and 2.8 ± 0.1 nm for D-glucuronic acid coated Na2WO4 and BaCO3 nanoparticles, respectively. All the nanoparticles exhibited a strong x-ray attenuation. In vivo CT images were obtained after intravenous injection of an aqueous sample suspension of D-glucuronic acid coated Na2WO4 nanoparticles, and positive contrast enhancements in the kidney were clearly shown. These findings indicate that the nanoparticles reported in this study may be promising CT contrast agents.

  3. Diagnostic and therapeutic research on ultrasound microbubble/nanobubble contrast agents (Review).

    PubMed

    Ma, Jing; Xu, Chang Song; Gao, Feng; Chen, Ming; Li, Fan; Du, Lian Fang

    2015-09-01

    The contrast enhanced imaging function of ultrasound contrast agents (UCAs) has been extensively investigated using physical acoustic signatures. It has a number of novel applications, including tissue‑specific molecular imaging and multi‑modal imaging. In addition there are numerous other therapeutic applications of UCAs, for example as vehicles for drug or gene delivery. These uses are discussed, as well as the acoustically‑induced biological effects, including ultrasound targeted microbubble destruction (UTMD). This review also explores the considerations for the safe use of UCA from an acoustic standpoint. The scope of the application of UCA has markedly expanded in recent years, and it is a rapidly growing field of medical research. The current article reviews recent advances in the diagnostic and therapeutic applications of ultrasound microbubble/nanobubble contrast agents. PMID:26081968

  4. Diagnosis of Popliteal Venous Entrapment Syndrome by Magnetic Resonance Imaging Using Blood-Pool Contrast Agents

    SciTech Connect

    Beitzke, Dietrich Wolf, Florian; Juelg, Gregor; Lammer, Johannes; Loewe, Christian

    2011-02-15

    Popliteal vascular entrapment syndrome is caused by aberrations or hypertrophy of the gastrocnemius muscles, which compress the neurovascular structures of the popliteal fossa, leading to symptoms of vascular and degeneration as well as aneurysm formation. Imaging of popliteal vascular entrapment may be performed with ultrasound, magnetic resonance imaging (MRI), computed tomography angiography, and conventional angiography. The use of blood-pool contrast agents in MRI when popliteal vascular entrapment is suspected offers the possibility to perform vascular imaging with first-pass magnetic resonance angiographic, high-resolution, steady-state imaging and allows functional tests all within one examination with a single dose of contrast agent. We present imaging findings in a case of symptomatic popliteal vein entrapment diagnosed by the use of blood pool contrast-enhanced MRI.

  5. Novel nano-sized MR contrast agent mediates strong tumor contrast enhancement in an oncogene-driven breast cancer model.

    PubMed

    Eriksson, Per-Olof; Aaltonen, Emil; Petoral, Rodrigo; Lauritzson, Petter; Miyazaki, Hideki; Pietras, Kristian; Månsson, Sven; Hansson, Lennart; Leander, Peter; Axelsson, Oskar

    2014-01-01

    The current study was carried out to test the potential of a new nanomaterial (Spago Pix) as a macromolecular magnetic MR contrast agent for tumor detection and to verify the presence of nanomaterial in tumor tissue. Spago Pix, synthesized by Spago Nanomedical AB, is a nanomaterial with a globular shape, an average hydrodynamic diameter of 5 nm, and a relaxivity (r1) of approximately 30 (mM Mn)-1 s-1 (60 MHz). The material consists of an organophosphosilane hydrogel with strongly chelated manganese (II) ions and a covalently attached PEG surface layer. In vivo MRI of the MMTV-PyMT breast cancer model was performed on a 3 T clinical scanner. Tissues were thereafter analyzed for manganese and silicon content using inductively coupled plasma-atomic emission spectroscopy (ICP-AES). The presence of nanomaterial in tumor and muscle tissue was assessed using an anti-PEG monoclonal antibody. MR imaging of tumor-bearing mice (n = 7) showed a contrast enhancement factor of 1.8 (tumor versus muscle) at 30 minutes post-administration. Contrast was retained and further increased 2-4 hours after administration. ICP-AES and immunohistochemistry confirmed selective accumulation of nanomaterial in tumor tissue. A blood pharmacokinetics analysis showed that the concentration of Spago Pix gradually decreased over the first hour, which was in good agreement with the time frame in which the accumulation in tumor occurred. In summary, we demonstrate that Spago Pix selectively enhances MR tumor contrast in a clinically relevant animal model. Based on the generally higher vascular leakiness in malignant compared to benign tissue lesions, Spago Pix has the potential to significantly improve cancer diagnosis and characterization by MRI. PMID:25296030

  6. TAILORING X-RAY BEAM ENERGY SPECTRUM TO ENHANCE IMAGE QUALITY OF NEW RADIOGRAPHY CONTRAST AGENTS BASED ON GD OR OTHER LANTHANIDES.

    SciTech Connect

    DILMANIAN,F.A.; WEINMANN,H.J.; ZHONG,Z.; BACARIAN,T.; RIGON,L.; BUTTON,T.M.; REN,B.; WU,X.Y.; ZHONG,N.; ATKINS,H.L.

    2001-02-17

    Gadovist, a 1.0-molar Gd contrast agent from Schering AG, Berlin Germany, in use in clinical MPI in Europe, was evaluated as a radiography contrast agent. In a collaboration with Brookhaven National Laboratory (BNL), Schering AG is developing several such lanthanide-based contrast agents, while BNL evaluates them using different x-my beam energy spectra. These energy spectra include a ''truly'' monochromatic beam (0.2 keV energy bandwidth) from the National Synchrotron Light Source (NSLS), BNL, tuned above the Gd K-edge, and x-ray-tube beams from different kVp settings and beam filtrations. Radiographs of rabbits' kidneys were obtained with Gadovist at the NSLS. Furthermore, a clinical radiography system was used for imaging rabbits' kidneys comparing Gadovist and Conray, an iodinated contrast agent. The study, using 74 kVp and standard Al beam filter for Conray and 66 kVp and an additional 1.5 mm Cu beam filter for Gadovist, produced comparable images for Gadovist and Conray; the injection volumes were the same, while the radiation absorbed dose for Gadovist was slightly smaller. A bent-crystal silicon monochromator operating in the Laue diffraction mode was developed and tested with a conventional x-ray tube beam; it narrows the energy spectrum to about 4 keV around the anode tungsten's Ku line. Preliminary beam-flux results indicate that the method could be implemented in clinical CT if x-ray tubes with {approximately} twice higher output become available.

  7. Targeted Multifunctional Multimodal Protein-Shell Microspheres as Cancer Imaging Contrast Agents

    PubMed Central

    John, Renu; Nguyen, Freddy T.; Kolbeck, Kenneth J.; Chaney, Eric J.; Marjanovic, Marina; Suslick, Kenneth S.; Boppart, Stephen A.

    2012-01-01

    Purpose In this study, protein-shell microspheres filled with a suspension of iron oxide nanoparticles in oil are demonstrated as multimodal contrast agents in magnetic resonance imaging (MRI), magnetomotive optical coherence tomography (MM-OCT), and ultrasound imaging. The development, characterization, and use of multifunctional multimodal microspheres are described for targeted contrast and therapeutic applications. Procedures A preclinical rat model was used to demonstrate the feasibility of the multimodal multifunctional microspheres as contrast agents in ultrasound, MM-OCT and MRI. Microspheres were functionalized with the RGD peptide ligand, which is targeted to αvβ3 integrin receptors that are over-expressed in tumors and atherosclerotic lesions. Results These microspheres, which contain iron oxide nanoparticles in their cores, can be modulated externally using a magnetic field to create dynamic contrast in MM-OCT. With the presence of iron oxide nanoparticles, these agents also show significant negative T2 contrast in MRI. Using ultrasound B-mode imaging at a frequency of 30 MHz, a marked enhancement of scatter intensity from in vivo rat mammary tumor tissue was observed for these targeted protein microspheres. Conclusions Preliminary results demonstrate multimodal contrast-enhanced imaging of these functionalized microsphere agents with MRI, MM-OCT, ultrasound imaging, and fluorescence microscopy, including in vivo tracking of the dynamics of these microspheres in real-time using a high-frequency ultrasound imaging system. These targeted oil-filled protein microspheres with the capacity for high drug-delivery loads offer the potential for local delivery of lipophilic drugs under image guidance. PMID:21298354

  8. The use of innovative gadolinium-based contrast agent for MR-diagnosis of cancer in the experiment

    NASA Astrophysics Data System (ADS)

    Chernov, V.; Medvedeva, A.; Sinilkin, I.; Zelchan, R.; Grigorev, E.; Frolova, I.; Nam, I.

    2016-02-01

    The present study of the functional suitability and specific activity of the contrast agent gadolinium-based for magnetic resonance imaging demonstrated that the investigated contrast agent intensively accumulates in organs and anatomical structures of the experimental animals. In the model of tumor lesions in animals, study have shown that investigational contrast agent accumulates in the tumor tissue and retained there in for a long enough time.

  9. Multimeric Near IR–MR Contrast Agent for Multimodal In Vivo Imaging

    PubMed Central

    2015-01-01

    Multiple imaging modalities are often required for in vivo imaging applications that require both high probe sensitivity and excellent spatial and temporal resolution. In particular, MR and optical imaging are an attractive combination that can be used to determine both molecular and anatomical information. Herein, we describe the synthesis and in vivo testing of two multimeric NIR–MR contrast agents that contain three Gd(III) chelates and an IR-783 dye moiety. One agent contains a PEG linker and the other a short alkyl linker. These agents label cells with extraordinary efficacy and can be detected in vivo using both imaging modalities. Biodistribution of the PEGylated agent shows observable fluorescence in xenograft MCF7 tumors and renal clearance by MR imaging. PMID:26083313

  10. NOTE: The effects of paramagnetic contrast agents on metabolite protons in aqueous solution

    NASA Astrophysics Data System (ADS)

    Murphy, Philip S.; Leach, Martin O.; Rowland, Ian J.

    2002-03-01

    The longitudinal (R1) and transverse (R2) relaxivities of the clinically used contrast agents Gd(DTPA)2-, Gd(DOTA)- and Gd(DTPA-BMA) have been determined in mixed aqueous metabolite solutions for choline, creatine and N-acetylaspartate. Measurements were performed at 1.5 T using a STEAM sequence on 25 mM metabolite solutions at pH = 7.4 and 22 °C. The data showed that for all the contrast agents and metabolites, R1 ~ R2. The largest range of relaxivity values was found for Gd(DTPA)2-, where R2 = 6.8 +/- 0.3 mM-1 s-1 for choline and 1.5 +/- 0.4 mM-1 s-1 for N-acetylaspartate. Variation in relaxivity values was attributed primarily to differences between the charges of the paramagnetic agent and metabolite. The maximum potential influence of the contrast agents on in vivo metabolite signals was calculated using the measured relaxivities.

  11. Molecular imaging of EGFR/HER2 cancer biomarkers by protein MRI contrast agents

    PubMed Central

    Qiao, Jingjuan; Xue, Shenghui; Pu, Fan; White, Natalie; Jiang, Jie; Liu, Zhi-Ren

    2014-01-01

    Epidermal growth factor receptor (EGFR) and HER2 are major prognosis biomarkers and drug targets overexpressed in various types of cancer cells. There is a pressing need to develop MRI contrast agents capable of enhancing the contrast between normal tissues and tumors with high relaxivity, capable of targeting tumors, and with high intratumoral distribution and minimal toxicity. In this review, we first discuss EGFR signaling and its role in tumor progression as a major drug target. We then report our progress in the development of protein contrast agents with significant improvement of both r1 and r2 relaxivities, pharmacokinetics, in vivo retention time, and in vivo dose efficiency. Finally, we report our effort in the development of EGFR-targeted protein contrast agents with the capability to cross the endothelial boundary and with good tissue distribution across the entire tumor mass. The noninvasive capability of MRI to visualize spatially and temporally the intratumoral distribution as well as quantify the levels of EGFR and HER2 would greatly improve our ability to track changes of the biomarkers during tumor progression, monitor treatment efficacy, aid in patient selection, and further develop novel targeted therapies for clinical application. PMID:24366655

  12. Thermal dependence of ultrasound contrast agents scattering efficiency for echographic imaging techniques

    NASA Astrophysics Data System (ADS)

    Biagioni, Angelo; Bettucci, Andrea; Passeri, Daniele; Alippi, Adriano

    2015-06-01

    Ultrasound contrast agents are used in echographic imaging techniques to enhance image contrast. In addition, they may represent an interesting solution to the problem of non-invasive temperature monitoring inside the human body, based on some thermal variations of their physical properties. Contrast agents, indeed, are inserted into blood circulation and they reach the most important organs inside the human body; consequently, any thermometric property that they may possess, could be exploited for realizing a non-invasive thermometer. They essentially are a suspension of microbubbles containing a gas enclosed in a phospholipid membrane; temperature variations induce structural modifications of the microbubble phospholipid shell, thus causing thermal dependence of contrast agent's elastic characteristics. In this paper, the acoustic scattering efficiency of a bulk suspension of of SonoVue® (Bracco SpA Milan, Italy) has been studied using a pulse-echo technique in the frequency range 1-17 MHz, as it depends upon temperatures between 25 and 65°C. Experimental data confirm that the ultrasonic attenuation coefficient of SonoVue® depends on temperature between 25 and 60°C. Chemical composition of the bubble shell seem to support the hypothesis that a phase transition in the microstructure of lipid-coated microbubbles could play a key role in explaining such effect.

  13. A naturally occurring contrast agent for OCT imaging of smokers' lung

    NASA Astrophysics Data System (ADS)

    Yang, Ying; Bagnaninchi, Pierre O.; Whiteman, Suzanne C.; Gey van Pittius, Daniel; El Haj, Alicia J.; Spiteri, Monica A.; Wang, Ruikang K.

    2005-08-01

    Optical coherence tomography (OCT) offers great potential for clinical applications in terms of its cost, safety and real-time imaging capability. Improvement of its resolution for revealing sub-layers or sub-cellular components within a tissue will further widen its application. In this study we report that carbon pigment, which is frequently present in the lungs of smokers, could be used as a contrast agent to improve the OCT imaging of lung tissue. Carbon produced an intense bright OCT image at a relatively deep location. The parallel histopathological section analysis confirmed the presence of carbon pigment in such tissues. The underlying mechanism of the OCT image formation has been discussed based on a model system in which carbon particles were dispersed in agar gel. Calculations and in-depth intensity profiles of OCT revealed that higher refractive index particles with a size close to or smaller than the wavelength would greatly increase backscattering and generate a sharp contrast, while a particle size several times larger than the wavelength would absorb or obstruct the light path. The naturally occurring contrast agent could provide a diagnostic biomarker of lung tissue in smokers. Furthermore, carbon under such circumstances, can be used as an effective exogenous contrast agent, with which specific components or tissues exhibiting early tumour formation can be optically labelled to delineate the location and boundary, providing potential for early cancer detection and its treatment.

  14. Maximizing Iodine Contrast-to-Noise Ratios in Abdominal CT Imaging through Use of Energy Domain Noise Reduction and Virtual Monoenergetic Dual-Energy CT1

    PubMed Central

    Leng, Shuai; Yu, Lifeng; Fletcher, Joel G.; McCollough, Cynthia H.

    2015-01-01

    Purpose To determine the iodine contrast-to-noise ratio (CNR) for abdominal computed tomography (CT) when using energy domain noise reduction and virtual monoenergetic dual-energy (DE) CT images and to compare the CNR to that attained with single-energy CT at 80, 100, 120, and 140 kV. Materials and Methods This HIPAA-compliant study was approved by the institutional review board with waiver of informed consent. A syringe filled with diluted iodine contrast material was placed into 30-, 35-, and 45-cm-wide water phantoms and scanned with a dual-source CT scanner in both DE and single-energy modes with matched scanner output. Virtual monoenergetic images were generated, with energies ranging from 40 to 110 keV in 10-keV steps. A previously developed energy domain noise reduction algorithm was applied to reduce image noise by exploiting information redundancies in the energy domain. Image noise and iodine CNR were calculated. To show the potential clinical benefit of this technique, it was retrospectively applied to a clinical DE CT study of the liver in a 59-year-old male patient by using conventional and iterative reconstruction techniques. Image noise and CNR were compared for virtual monoenergetic images with and without energy domain noise reduction at each virtual monoenergetic energy (in kiloelectron volts) and phantom size by using a paired t test. CNR of virtual monoenergetic images was also compared with that of single-energy images acquired with 80, 100, 120, and 140 kV. Results Noise reduction of up to 59% (28.7/65.7) was achieved for DE virtual monoenergetic images by using an energy domain noise reduction technique. For the commercial virtual monoenergetic images, the maximum iodine CNR was achieved at 70 keV and was 18.6, 16.6, and 10.8 for the 30-, 35-, and 45-cm phantoms. After energy domain noise reduction, maximum iodine CNR was achieved at 40 keV and increased to 30.6, 25.4, and 16.5. These CNRs represented improvement of up to 64% (12.0/18.6) with

  15. Nanoparticles as magnetic resonance imaging contrast agents for vascular and cardiac diseases

    PubMed Central

    Chen, Wei; Cormode, David P.; Fayad, Zahi A.; Mulder, Willem J. M.

    2011-01-01

    Advances in nanoparticle contrast agents for molecular imaging have made magnetic resonance imaging a promising modality for noninvasive visualization and assessment of vascular and cardiac disease processes. This review provides a description of the various nanoparticles exploited for imaging cardiovascular targets. Nanoparticle probes detecting inflammation, apoptosis, extracellular matrix, and angiogenesis may provide tools for assessing the risk of progressive vascular dysfunction and heart failure. The utility of nanoparticles as multimodal probes and/or theranostic agents has also been investigated. Although clinical application of these nanoparticles is largely unexplored, the potential for enhancing disease diagnosis and treatment is considerable. PMID:20967875

  16. Research into europium complexes as magnetic resonance imaging contrast agents (Review)

    PubMed Central

    HAN, GUOCAN; DENG, YANGWEI; SUN, JIHONG; LING, JUN; SHEN, ZHIQUAN

    2015-01-01

    Europium (Eu) is a paramagnetic lanthanide element that possesses an outstanding luminescent property. Eu complexes are ideal fluorescence imaging (FI) agents. Eu2+ has satisfactory relaxivity and optical properties, and can realize magnetic resonance (MRI)-FI dual imaging applications when used with appropriate cryptands that render it oxidatively stable. By contrast, based on the chemical exchange saturation transfer (CEST) mechanism, Eu3+ complexes can provide enhanced MRI sensitivity when used with optimal cryptands, incorporated into polymeric CEST agents or blended with Gd3+. Eu complexes are promising in MRI-FI dual imaging applications and have a bright future. PMID:26136858

  17. Dual Contrast Agent for Computed Tomography and Magnetic Resonance Hard Tissue Imaging

    PubMed Central

    Ventura, Manuela; Sun, Yi; Rusu, Viorel; Laverman, Peter; Borm, Paul; Heerschap, Arend; Oosterwijk, Egbert; Boerman, Otto C.; Walboomers, X. Frank

    2013-01-01

    Calcium phosphate cements (CPCs) are commonly used bone substitute materials, which closely resemble the composition of the mineral phase of bone. However, this high similarity to natural bone also results in difficult discrimination from the bone tissue by common imaging modalities, that is, plain X-ray radiography and three-dimensional computed tomography (CT). In addition, new imaging techniques introduced for bone tissue visualization, like magnetic resonance imaging (MRI), face a similar problem. Even at high MRI resolution, the lack of contrast between CPCs and surrounding bone is evident. Therefore, this study aimed to evaluate the feasibility of a dual contrast agent, traceable with both CT and MRI as enhancers of CPC/bone tissue contrast. Our formulation is based on the use of silica beads as vectors, which encapsulate and carry contrast-enhancing nanoparticles, in our case, colloidal Gold and Superparamagnetic Iron oxide particles (SPIO). The bead suspension was incorporated within a calcium phosphate powder. The resultant cements were then tested both in vitro and in vivo in a femoral condyle defect model in rats. Results showed that the mechanical properties of the cement were not significantly affected by the inclusion of the beads. Both in vitro and in vivo data proved the homogeneous incorporation of the contrast within the cement and its visual localization, characterized by a short-term CT contrast enhancement and a long-term MR effect recognizable by the characteristic blooming shape. Finally, no signs of adverse tissue reactions were noticed in vivo. In conclusion, this study proved the feasibility of a multimodal contrast agent as an inert and biocompatible enhancer of CaP cement versus bone tissue contrast. PMID:23259682

  18. Safety of intravenous application of second-generation ultrasound contrast agent in children: prospective analysis.

    PubMed

    Piskunowicz, Maciej; Kosiak, Wojciech; Batko, Tomasz; Piankowski, Arkadiusz; Połczyńska, Katarzyna; Adamkiewicz-Drożyńska, Elżbieta

    2015-04-01

    The goal of the work described here was to assess the safety profile of intravenous second-generation ultrasound contrast agents (UCAs) containing sulfur hexafluoride in pediatric contrast-enhanced ultrasound. Between 2010 and 2013, a total of 167 examinations were performed in 137 children referred by the Oncology Department. Approval by an Independent Ethical Review Board on Scientific Research for the intravenous use of an UCA containing sulfur hexafluoride in children with oncologic diseases was obtained. Consent for UCA administration was acquired from the parents or legal guardians. Severe anaphylactic reaction was observed in 0.6% (n = 1). No other adverse events during or after intravenous administration of contrast were observed in the examined group (no changes in heart rate and rhythm, blood pressure, oxygen saturation or respiratory rate). There were no reports of subjective flushing, nausea, transient headaches or altered taste. Although second-generation ultrasound contrast agents are considered potentially safe, all investigators should be prepared for the development of adverse reactions and have provisions in place for all pediatric intravenous contrast-enhanced ultrasound examinations. More multicenter studies are essential to determination of an accurate UCA safety profile. PMID:25701526

  19. Investigation of lanthanide-based starch particles as a model system for liver contrast agents.

    PubMed

    Fossheim, S L; Kellar, K E; Mansson, S; Colet, J M; Rongved, P; Fahlvik, A K; Klaveness, J

    1999-02-01

    Gadolinium and dysprosium diethylenetriamine pentaacetic acid-labeled starch microparticles (Gd-DTPA-SP and Dy-DTPA-SP) were investigated as model liver contrast agents. The liver contrast efficacy of particles with low and high metal contents was compared in two imaging models: in vivo rat liver and ex vivo perfused rat liver. The biodistribution of intravenously injected particles was also assessed by ex vivo relaxometry and inductively coupled plasma atomic emission spectrophotometry of tissues. All particles reduced the liver signal intensity on T2-weighted spin-echo and gradient-recalled echo images as a result of susceptibility effects. Because of their higher magnetic susceptibility, the Dy-DTPA-SP were more effective negative contrast enhancers than the Gd-DTPA-SP. On T1-weighted spin-echo images, only the Gd-DTPA-SP with low metal content significantly increased the liver signal intensity. In addition, these low-loading Gd-DTPA-SP markedly reduced the blood T1. The two latter observations were not consistent with the anticipated blood circulation time of microparticles, but were a result of the lower stability of these particles in blood compared with Gd-DTPA-SP, which has a high metal content. Regardless of stability or imaging conditions, the paramagnetic starch particles investigated showed potential as negative liver contrast enhancers. However, the observed accumulation of particles in the lungs represented a biological limitation for their use as contrast agents. PMID:10077028

  20. Balancing stealth and echogenic properties in an ultrasound contrast agent with drug delivery potential.

    PubMed

    Jablonowski, Lauren J; Alfego, David; Andorko, James I; Eisenbrey, John R; Teraphongphom, Nutte; Wheatley, Margaret A

    2016-10-01

    Contrast agents are currently being modified to combine diagnostic and therapeutic capabilities. For ultrasound (US) imaging with polymeric contrast agents, it is necessary to modify the shell to create "stealth" microbubbles but without these modifications sacrificing the agent's ability to interact with the focused US beam. We hypothesize that addition of the classic immune shielding molecule polyethylene glycol (PEG) to a polylactide (PLA) microbubble shell will affect the acoustic and physical properties of the resulting agents. In an effort to determine the best formulation to achieve a balance between stealth and acoustic activity, we compared two PEGylation techniques; addition of increasing amounts of PEG-PLA copolymer and employing incorporation of a PEG lipid (LipidPEG) into the shell. Loss of acoustic enhancement occurred in a dose-dependent manner for both types of PEGylated agents (loss of signal occurred at >5 wt% PEG-PLA and >1 wt% LipidPEG), while immune activation was also reduced in a dose-dependent manner for the PEG-PLA agents. This study shows that the balance between acoustic behavior and improved immune avoidance was scalable and successful to different degrees with both PEGylation methods, and was best achieved using for PEG-PLA at 5 wt% and for LipidPEG at 1 wt%. Studies are ongoing to evaluate the best method for the targeting and drug delivery capabilities of these agents for applications in cancer treatment. This study represents the basis for understanding the consequences of making modifications to the native polymeric shell. PMID:27388945

  1. A nano-sized PARACEST-fluorescence imaging contrast agent facilitates & validates in vivo CEST MRI detection of glioma

    PubMed Central

    Ali, Meser M; Bhuiyan, Mohammed PI; Janic, Branislava; Varma, Nadimpalli RS; Mikkelsen, Tom; Ewing, James R; Knight, Robert A; Pagel, Mark D; Arbab, Ali S

    2012-01-01

    Aim The authors have investigated the usefulness of in vivo chemical exchange saturation transfer MRI for detecting gliomas using a dual-modality imaging contrast agent. Materials & methods A paramagnetic chemical exchange saturation transfer MRI contrast agent, Eu-1,4,7,10-tetraazacclododecane-1,4,7,10-tetraacetic acid-Gly4 and a fluorescent agent, DyLight® 680, were conjugated to a generation 5 polyamidoamine dendrimer to create the dual-modality, nano-sized imaging contrast agent. Results The agent was detected with in vivo chemical exchange saturation transfer MRI in an U87 glioma model. These results were validated using in vivo and ex vivo fluorescence imaging. Conclusion This study demonstrated the merits of using a nano-sized imaging contrast agent for detecting gliomas and using a dual-modality agent for detecting gliomas at different spatial scales. PMID:22891866

  2. Imaging translucent cell bodies in the living mouse retina without contrast agents.

    PubMed

    Guevara-Torres, A; Williams, D R; Schallek, J B

    2015-06-01

    The transparency of most retinal cell classes typically precludes imaging them in the living eye; unless invasive methods are used that deploy extrinsic contrast agents. Using an adaptive optics scanning light ophthalmoscope (AOSLO) and capitalizing on the large numerical aperture of the mouse eye, we enhanced the contrast from otherwise transparent cells by subtracting the left from the right half of the light distribution in the detector plane. With this approach, it is possible to image the distal processes of photoreceptors, their more proximal cell bodies and the mosaic of horizontal cells in the living mouse retina. PMID:26114032

  3. Gd-doped BNNTs as T2-weighted MRI contrast agents

    NASA Astrophysics Data System (ADS)

    Ciofani, Gianni; Boni, Adriano; Calucci, Lucia; Forte, Claudia; Gozzi, Alessandro; Mazzolai, Barbara; Mattoli, Virgilio

    2013-08-01

    This work describes, for the first time, doping of boron nitride nanotubes (BNNTs) with gadolinium (Gd@BNNTs), a stable functionalization that permits non-invasive BNNT tracking via magnetic resonance imaging (MRI). We report the structure, Gd loading, and relaxometric properties in water suspension at 7 T of Gd@BNNTs, and show the behaviour of these nanostructures as promising T2-weighted contrast agents. Finally, we demonstrate their complete biocompatibility in vitro on human neuroblastoma cells, together with their ability to effectively label and affect contrast in MRI images at 7 T.

  4. Gadolinium-based contrast agents: did we miss something in the last 25 years?

    PubMed

    Beomonte Zobel, Bruno; Quattrocchi, Carlo Cosimo; Errante, Yuri; Grasso, Rosario Francesco

    2016-06-01

    In the last 24 months, several clinical and experimental studies, suggested first and demonstrated later, a progressive concentration of Gadolinium in the brain of normal renal function patients, following repeated injections of some of the commercially approved Gadolinium-Based Contrast Agents. Although, till now, Gadolinium brain deposits have not been associated to any kind of neurological signs or symptoms, they oblige the radiology community to modify the actual approach in using Gadolinium contrast media in daily practice, to reduce unknown possible risks for patients. PMID:26706453

  5. Gadolinium-phthalein complexone as a contrast agent for hepatobiliary MR imaging

    SciTech Connect

    Kawamura, Y.; Endo, K.; Koizumi, M.; Watanabe, Y.; Saga, T.; Konishi, J.; Horiuchi, K.; Yokoyama, A.

    1989-01-01

    Gadolinium-phthalein complexone (Gd-PC) was developed as a hepatobiliary magnetic resonance (MR) contrast agent. Phthalein complexone is one of the iminodiacetic acid derivatives and a structural analogue of bromosulfophthalein. Gadolinium-PC substantially enhanced signal intensity of normal functioning livers on T1-weighted MR images. Contrast enhancement of rabbit liver and gradual accumulation of high intensity bile in the gallbladder were observed after intravenous injection of 0.05 and 0.1 mmol/kg Gd-PC. However, 0.1 mmol/kg of Gd-DTPA caused little effect on liver MR.

  6. Imaging translucent cell bodies in the living mouse retina without contrast agents

    PubMed Central

    Guevara-Torres, A.; Williams, D. R.; Schallek, J. B.

    2015-01-01

    The transparency of most retinal cell classes typically precludes imaging them in the living eye; unless invasive methods are used that deploy extrinsic contrast agents. Using an adaptive optics scanning light ophthalmoscope (AOSLO) and capitalizing on the large numerical aperture of the mouse eye, we enhanced the contrast from otherwise transparent cells by subtracting the left from the right half of the light distribution in the detector plane. With this approach, it is possible to image the distal processes of photoreceptors, their more proximal cell bodies and the mosaic of horizontal cells in the living mouse retina. PMID:26114032

  7. Synthesis, X-ray Opacity, and Biological Compatibility of Ultra-High Payload Elemental Bismuth Nanoparticle X-ray Contrast Agents

    PubMed Central

    2015-01-01

    Inorganic nanoscale X-ray contrast agents (XCAs) offer many potential advantages over currently used intravascular molecular contrast agents, including longer circulation and retention times, lower administration volumes, and greater potential for site directed imaging. Elemental bismuth nanoparticles (BiNPs) are particularly attractive candidate XCAs due to the low cost, the high atomic number and high density of bismuth, and the likelihood that BiNPs will oxidatively decompose to biocompatible bismuth(III) ions at controlled rates for renal excretion. Herein we describe the synthesis of ultrahigh payload BiNPs in 1,2-propanediol using a borane reducing agent and glucose as a biocompatible surface stabilizer. Both synthetic solvent (1,2-propanediol) and surfactant (glucose) are evident on the BiNP surfaces when analyzed by 1H NMR and FT-IR spectroscopies. These particles contain ∼6 million Bi atoms per NP and have large inorganic cores (74 nm by TEM) compared to their hydrodynamic size (86 nm by DLS). Thus, the dense BiNP core constitutes the majority (∼60%) of each particle’s volume, a necessary property to realize the full potential of nanoscale XCAs. Using quantitative computed tomography in phantom and in vitro imaging studies, we demonstrate that these BiNPs have greater X-ray opacity than clinical small molecule iodinated contrast agents at the same concentrations. We furthermore demonstrate a favorable biocompatibility profile for these BiNPs in vitro. Altogether, these studies indicate that these ultrahigh payload BiNPs, synthesized from known biocompatible components, have promising physical and cytotoxicological properties for use as XCAs. PMID:24803727

  8. Hydroxy double salts intercalated with Mn(II) complexes as potential contrast agents

    NASA Astrophysics Data System (ADS)

    Jin, Miao; Li, Wanjing; Spillane, Dominic E. M.; Geraldes, Carlos F. G. C.; Williams, Gareth R.; Bligh, S. W. Annie

    2016-03-01

    A series of Mn(II) aminophosphonate complexes were successfully synthesized and intercalated into the hydroxy double salt [Zn5(OH)8]Cl2·yH2O. Complex incorporation led to an increase in the interlayer spacing from 7.8 to 10-12 Å. Infrared spectroscopy showed the presence of the characteristic vibration peaks of the Mn(II) complexes in the intercalates' spectra, indicating successful incorporation. The complex-loaded composites had somewhat lower proton relaxivities than the pure complexes. Nevertheless, these intercalates may have use as MRI contrast agents for patients with poor kidney function, where traditional Gd(III)-based contrast agents cause severe renal failure.

  9. Gd(III) complexes intercalated into hydroxy double salts as potential MRI contrast agents.

    PubMed

    Jin, Miao; Spillane, Dominic E M; Geraldes, Carlos F G C; Williams, Gareth R; Bligh, S W Annie

    2015-12-21

    The ion exchange intercalation of two Gd-based magnetic resonance imaging contrast agents into hydroxy double salts (HDSs) is reported. The presence of Gd(3+) diethylenetriaminepentaacetate and Gd(3+) diethylenetriaminepenta(methylenephosphonate) complexes in the HDS lattice after intercalation was confirmed by microwave plasma-atomic emission spectroscopy. The structural aspects of the HDS-Gd composites were studied by X-ray diffraction, with the intercalates having an interlayer spacing of 14.5-18.6 Å. Infrared spectroscopy confirmed the presence of characteristic vibration peaks associated with the Gd(3+) complexes in the intercalation compounds. The proton relaxivities of the Gd(3+) complex-loaded composites were 2 to 5-fold higher in longitudinal relaxivity, and up to 10-fold higher in transverse relaxivity, compared to solutions of the pure complexes. These data demonstrate that the new composites reported here are potentially potent MRI contrast agents. PMID:26568157

  10. Octapod iron oxide nanoparticles as high-performance T₂ contrast agents for magnetic resonance imaging.

    PubMed

    Zhao, Zhenghuan; Zhou, Zijian; Bao, Jianfeng; Wang, Zhenyu; Hu, Juan; Chi, Xiaoqin; Ni, Kaiyuan; Wang, Ruifang; Chen, Xiaoyuan; Chen, Zhong; Gao, Jinhao

    2013-01-01

    Spherical superparamagnetic iron oxide nanoparticles have been developed as T2-negative contrast agents for magnetic resonance imaging in clinical use because of their biocompatibility and ease of synthesis; however, they exhibit relatively low transverse relaxivity. Here we report a new strategy to achieve high transverse relaxivity by controlling the morphology of iron oxide nanoparticles. We successfully fabricate size-controllable octapod iron oxide nanoparticles by introducing chloride anions. The octapod iron oxide nanoparticles (edge length of 30 nm) exhibit an ultrahigh transverse relaxivity value (679.3 ± 30 mM(-1) s(-1)), indicating that these octapod iron oxide nanoparticles are much more effective T2 contrast agents for in vivo imaging and small tumour detection in comparison with conventional iron oxide nanoparticles, which holds great promise for highly sensitive, early stage and accurate detection of cancer in the clinic. PMID:23903002

  11. Preclinical animal acute toxicity studies of new developed MRI contrast agent based on gadolinium

    NASA Astrophysics Data System (ADS)

    Nam, I. F.; Zhuk, V. V.

    2015-04-01

    Acute toxicity test of new developed MRI contrast agent based on disodium salt of gadopentetic acid complex were carried out on Mus musculus and Sprague Dawley rats according to guidelines of preclinical studies [1]. Groups of six animals each were selected for experiment. Death and clinical symptoms of animals were recorded during 14 days. As a result the maximum tolerated dose (MTD) for female mice is 2.8 mM/kg of body weight, male mice - 1.4 mM/kg, female rats - 2.8 mM/kg, male rats - 5.6 mM/kg of body weight. No Observed Adverse Effect Dose (NOAEL) for female mice is 1.4 mM/kg, male mice - 0.7 mM/kg, male and female rats - 0.7 mM/kg. According to experimental data new developed MRI contrast agent based on Gd-DTPA complex is low-toxic.

  12. Biocompatible Polyhydroxyethylaspartamide-based Micelles with Gadolinium for MRI Contrast Agents

    NASA Astrophysics Data System (ADS)

    Jeong, Sang Young; Kim, Hyo Jeong; Kwak, Byung-Kook; Lee, Ha-Young; Seong, Hasoo; Shin, Byung Cheol; Yuk, Soon Hong; Hwang, Sung-Joo; Cho, Sun Hang

    2010-12-01

    Biocompatible poly-[ N-(2-hydroxyethyl)- d, l-aspartamide]-methoxypoly(ethyleneglycol)-hexadecylamine (PHEA-mPEG-C16) conjugated with 1,4,7,10-tetraazacyclododecan-1,4,7,10-tetraacetic acid-gadolinium (DOTA-Gd) via ethylenediamine (ED) was synthesized as a magnetic resonance imaging (MRI) contrast agent. Amphiphilic PHEA-mPEG-C16-ED-DOTA-Gd forms micelle in aqueous solution. All the synthesized materials were characterized by proton nuclear magnetic resonance (1H NMR). Micelle size and shape were examined by dynamic light scattering (DLS) and atomic force microscopy (AFM). Micelles with PHEA-mPEG-C16-ED-DOTA-Gd showed higher relaxivities than the commercially available gadolinium contrast agent. Moreover, the signal intensity of a rabbit liver was effectively increased after intravenous injection of PHEA-mPEG-C16-ED-DOTA-Gd.

  13. Characterization of the thermalisation efficiency and photostability of photoacoustic contrast agents

    NASA Astrophysics Data System (ADS)

    Stahl, T.; Allen, T.; Beard, P.

    2014-03-01

    A simple method of characterizing organic dyes and nanoparticles used as contrast agents for photoacoustic molecular imaging based on relative photoacoustic measurements is described. By acquiring just two time-resolved photoacoustic signals, one in the sample of interest and the other in water, measurements of the thermalisation efficiency and other parameters relevant to the characterization of contrast agents can be acquired. The method was validated using absorbing solutions of known thermalisation efficiency and Grüneisen coefficient. It was then used to measure the thermalisation efficiency of solutions of gold nanorods, rhodamine B, methylene blue, IR-820, fluorescein and cresyl violet. In addition, photoacoustic measurements of the photostability of these substances were acquired.

  14. Molecular imaging of atherosclerosis with nanoparticle-based fluorinated MRI contrast agents

    PubMed Central

    Palekar, Rohun U; Jallouk, Andrew P; Lanza, Gregory M; Pan, Hua; Wickline, Samuel A

    2015-01-01

    As atherosclerosis remains one of the most prevalent causes of patient mortality, the ability to diagnose early signs of plaque rupture and thrombosis represents a significant clinical need. With recent advances in nanotechnology, it is now possible to image specific molecular processes noninvasively with MRI, using various types of nanoparticles as contrast agents. In the context of cardiovascular disease, it is possible to specifically deliver contrast agents to an epitope of interest for detecting vascular inflammatory processes, which serve as predecessors to atherosclerotic plaque development. Herein, we review various applications of nanotechnology in detecting atherosclerosis using MRI, with an emphasis on perfluorocarbon nanoparticles and fluorine imaging, along with theranostic prospects of nanotechnology in cardiovascular disease. PMID:26080701

  15. Synthesis of functionalized magnetite nanoparticles to use as liver targeting MRI contrast agent

    NASA Astrophysics Data System (ADS)

    Yazdani, Farshad; Fattahi, Bahare; Azizi, Najmodin

    2016-05-01

    The aim of this research was the preparation of functionalized magnetite nanoparticles to use as a liver targeting contrast agent in magnetic resonance imaging (MRI). For this purpose, Fe3O4 nanoparticles were synthesized via the co-precipitation method. The synthesized nanoparticles were coated with silica via the Stober method and finally the coated nanoparticles were functionalized with mebrofenin. Formation of crystalline magnetite particles was confirmed by X-ray diffraction (XRD) analysis. The Fourier transform infrared spectroscopy (FTIR) and energy dispersive X-ray analyzer (EDX) of the final product showed that silica had been effectively bonded onto the surface of the magnetite nanoparticles and the coated nanoparticles functionalized with mebrofenin. The magnetic resonance imaging of the functional nanoparticles showed that the Fe3O4-SiO2-mebrofenin composite is an effective MRI contrast agent for liver targeting.

  16. Highly Uniform Perfluoropropane-Loaded Cerasomal Microbubbles As a Novel Ultrasound Contrast Agent.

    PubMed

    Zhang, Chunyang; Wang, Zhu; Wang, Chunan; Li, Xiongjun; Liu, Jie; Xu, Ming; Xu, Shuyu; Xie, Xiaoyan; Jiang, Qing; Wang, Wei; Cao, Zhong

    2016-06-22

    Microbubbles are widely used as ultrasound contrast agents owing to their excellent echoing characteristics under ultrasound radiation. However, their short sonographic duration and wide size distribution still hinder their application. Herein, we present a hard-template approach to produce perfluoropropane-loaded cerasomal microbubbles (PLCMs) with uniform size and long sonographic duration. The preparation of PLCMs includes deposition of Si-lipids onto functionalized CaCO3 microspheres, removal of their CaCO3 cores and mild infusion of perfluoropropane. In vitro and in vivo experiments showed that PLCMs had excellent echoing characteristics under different ultrasound conditions. More importantly, PLCMs could be imaged for much longer than SonoVue (commercially used microbubbles) under the same ultrasound parameters and concentrations. Our results demonstrated that PLCMs have great potential for use as a novel contrast agent in ultrasound imaging. PMID:26114237

  17. A responsive particulate MRI contrast agent for copper (I): a cautionary tale

    PubMed Central

    Smolensky, Eric D.; Marjańska, Małgorzata

    2013-01-01

    A responsive MION-based MRI contrast agent for the detection of copper(I) is presented. Induced agglomeration of azide and acetylene-functionalized magnetite nanoparticles via Cu(I) catalysed Huisgen cycloaddition leads to significant decrease in longitudinal relaxivity due to the slow exchange of water molecules trapped within the cluster with bulk solvent. Agglomeration leads to an initial two fold increase followed by a sharp and almost complete loss in transverse relaxivity for clusters larger than 200 nm in size. The decrease in r2 for clusters reaching the static dephasing regime has two significant implications for particulate responsive MRI contrast agents. First, the maximum increase in r2 is barely two fold, second, since r2 does not increase continuously with increasing cluster size, the r1/r2 ratio cannot be used to determine the concentration of an analyte ratiometrically. PMID:22585342

  18. Biochemical Safety Profiles of Gadolinium-Based Extracellular Contrast Agents and Nephrogenic Systemic Fibrosis

    PubMed Central

    Ersoy, Hale; Rybicki, Frank J.

    2009-01-01

    Gadolinium (Gd)-based paramagnetic contrast agents are relatively safe when used in clinically recommended doses. However, with the rapidly expanding body of literature linking Gd-based paramagnetic contrast agents and nephrogenic systemic fibrosis (NSF), awareness of the potential side effects and adverse reactions from Gd is now an important requirement for practicing radiologists. In addition to the ongoing accumulation and analyses of clinical NSF data, it is also essential for the practicing radiologist to understand the biochemical characteristics of the extracellular Gd-chelates. The purpose of this review is to consolidate and update the available information on known side effects, adverse reactions, and toxicity of the Gd chelates, with particular emphasis on the potential mechanisms of NSF. PMID:17969161

  19. Biocompatible and high-performance amino acids-capped MnWO4 nanocasting as a novel non-lanthanide contrast agent for X-ray computed tomography and T1-weighted magnetic resonance imaging

    NASA Astrophysics Data System (ADS)

    Dong, Kai; Liu, Zhen; Liu, Jianhua; Huang, Sa; Li, Zhenhua; Yuan, Qinghai; Ren, Jinsong; Qu, Xiaogang

    2014-01-01

    In the present work, a novel non-lanthanide dual-modality contrast agent, manganese tungstate (MnWO4), has been successfully constructed by a facile and versatile hydrothermal route. With the merits of a high atomic number and a well-positioned K-edge energy of tungsten, our well-prepared non-lanthanide nanoprobes provide a higher contrast efficacy than routine iodine-based agents in clinics. Additionally, the presence of Mn in these nanoparticles endow them with excellent T1-weighted MR imaging capabilities. As an alternative to T2-weighted MRI and CT dual-modality contrast agents, the nanoprobes can provide a positive contrast signal, which prevents confusion with the dark signals from hemorrhage and blood clots. To the best of our knowledge, this is the first report that a non-lanthanide imaging nanoprobe is applied for CT and T1-weighted MRI simultaneously. Moreover, comparing with gadolinium-based T1-weighted MRI and CT dual-modality contrast agents that were associated with nephrogenic systemic fibrosis (NSF), our contrast agents have superior biocompatibility, which is proved by a detailed study of the pharmacokinetics, biodistribution, and in vivo toxicology. Together with excellent dispersibility, high biocompatibility and superior contrast efficacy, these nanoprobes provide detailed and complementary information from dual-modality imaging over traditional single-mode imaging and bring more opportunities to the new generation of non-lanthanide nanoparticulate-based contrast agents.In the present work, a novel non-lanthanide dual-modality contrast agent, manganese tungstate (MnWO4), has been successfully constructed by a facile and versatile hydrothermal route. With the merits of a high atomic number and a well-positioned K-edge energy of tungsten, our well-prepared non-lanthanide nanoprobes provide a higher contrast efficacy than routine iodine-based agents in clinics. Additionally, the presence of Mn in these nanoparticles endow them with excellent T1

  20. A synergistically enhanced T(1) -T(2) dual-modal contrast agent.

    PubMed

    Zhou, Zijian; Huang, Dengtong; Bao, Jianfeng; Chen, Qiaoli; Liu, Gang; Chen, Zhong; Chen, Xiaoyuan; Gao, Jinhao

    2012-12-01

    Monodisperse Gd(2) O(3) -embedded iron oxide (GdIO) nanoparticles can simultaneously enhance the local magnetic field intensities of each other under an external magnetic field and result in synergistic enhancement of T(1) and T(2) effects. GdIO nanoparticles have the unique property to be both T(1) and T(2) contrast agents and can potentially lead to higher accuracy in cancer diagnosis, particularly liver tumors. PMID:22972529

  1. Evaluation of a novel gadolinium-based contrast agent for intraoperative magnetic resonance imaging

    NASA Astrophysics Data System (ADS)

    Madsen, Steen J.; Wu, Genevieve N.; Chow, Rayland; Kim, Sung-Yop; Hirschberg, Henry

    2008-02-01

    The aim of this experimental study was to determine whether Motexafin Gadolinium (MGd) could serve as an efficient intraoperative contrast agent avoiding problems that arise with surgically-induced intracranial enhancement. F98 orthotopic brain tumors or surgical lesions were induced in Fisher rats. T1-weighted MRI studies were performed with either a single or multiple daily doses of MGd. The last contrast dose was administered either 7 or 24 h prior to scanning in both tumor-bearing and surgically treated animals. Animals receiving either 30 or 60 mg/kg MGd i.v. developed clinical signs of impaired motor activity, and increasing lethargy. MGd given i.p. was tolerated up to a dose of 140 mg/kg. Despite multiple dosages, and several administration modes (i.p. and i.v.), no significant enhancement was observed if the scans were performed 7 or 24 h following the last MGd dose. Clear enhancement was observed if the scans were performed 30 min. following MGd administration. Scans of necrotic lesions were positive 7 h post MGd injection. MGd scans showed no significant enhancement following surgically-induced lesions while scans with conventional contrast agents showed both meningeal and intraparenchymal enhancement. This study suggests that MGd is not sequestered in viable tumor for the necessary time interval required to allow delayed imaging in this model. The agent does seem to remain in necrotic tissue for longer time intervals. MGd therefore would not be suitable as a contrast agent in iMRI for the detection of residual tumor tissue during surgery.

  2. Estimation of contrast agent concentration in intra- and extra-vascular spaces of brain tissue.

    PubMed

    Yahaghi, E; Soltanian-Zadeh, H; Shahriari, M; Fatouraee, N; Ewing, J R

    2006-11-01

    This article presents a new method for estimating the leakage of a contrast agent out of a vessel. The proposed method is developed based on tissue homogeneity (TH) model, modified Patlak model, and Monte Carlo simulation. The analytical methods published in the literature estimate the contrast agent leakage by solving the coupled differential equations associated with the TH model under adiabatic conditions. These methods employ unrealistic simplifying assumptions and become intractable in their applications to the vessels that have a non-uniform permeability. Without making any unrealistic assumptions, our approach simply tracks the passage of the contrast agent through the capillary and its crossing of the vessel walls based on the blood flow in the vessel, the vessel's permeability, and the condition of the blood-brain barrier (BBB). These are treated as statistical processes that can be modeled reasonably well using the Monte Carlo method. In the proposed approach, the intra- and extra-vascular spaces are divided into multiple compartments, similar to the Patlak model. A real, measured arterial input function (AIF) is used as the capillary input and the concentration of the contrast agent is found as a function of time and distance, inside and outside of the capillary. This is done for normal and abnormal capillaries with uniform and non-uniform permeability. The proposed method generates concentration curves similar to those of the analytical method for simple AIF models. It also generates reasonable concentration curves for a real AIF. The proposed method does not fit a mathematical function to the measured AIF and does not make unrealistic simplifying assumptions. It is not therefore prone to the fitting errors and generates more realistic and more accurate results than the analytical methods. PMID:16978665

  3. Metal-oxo containing polymer nanobeads as potential contrast agents for magnetic resonance imaging

    NASA Astrophysics Data System (ADS)

    Pablico, Michele Huelar

    Magnetic resonance imaging (MRI) has greatly revolutionized the way diseases are detected and treated, as it is a non-invasive imaging modality solely based on the interaction of radiowaves and hydrogen nuclei in the presence of an external magnetic field. It is widely used today for the diagnosis of diseases as it offers an efficient method of mapping structure and function of soft tissues in the body. Most MRI examinations utilize paramagnetic materials known as contrast agents, which enhance the MR signal by decreasing the longitudinal (T1) and transverse (T2) relaxation times of the surrounding water protons in biological systems. This results into increased signal intensity differences thereby allowing better interpretation and analysis of pathological tissues. Contrast agents function by lowering the T1 or lowering the T2, resulting into bright and dark contrasts, respectively. The most common MRI contrast agents that are in clinical use today are gadolinium chelates and superparamagnetic iron oxide nanoparticles, both of which have their own advantages in terms of contrast enhancement properties. In the past few years, however, there has been interest in utilizing metal-containing clusters for MRI contrast enhancement as these materials bridge the gap between the constrained structure and magnetic properties of the gadolinium chelates with the superparamagnetic behavior of the iron oxide nanoparticles. Recently, metallic clusters containing Mn and Fe metal centers have received increased attention mainly because of their potential for high spin states and benign nature. In the quest to further develop novel imaging agents, this research has focused on investigating the use of metal-oxo clusters as potential contrast agents for MRI. The primary goal of this project is to identify clusters that meet the following criteria: high paramagnetic susceptibility, water-soluble, stable, cheap, contain environmentally benign metals, and easily derivatized. This work is

  4. Neurosurgical confocal endomicroscopy: A review of contrast agents, confocal systems, and future imaging modalities

    PubMed Central

    Zehri, Aqib H.; Ramey, Wyatt; Georges, Joseph F.; Mooney, Michael A.; Martirosyan, Nikolay L.; Preul, Mark C.; Nakaji, Peter

    2014-01-01

    Background: The clinical application of fluorescent contrast agents (fluorescein, indocyanine green, and aminolevulinic acid) with intraoperative microscopy has led to advances in intraoperative brain tumor imaging. Their properties, mechanism of action, history of use, and safety are analyzed in this report along with a review of current laser scanning confocal endomicroscopy systems. Additional imaging modalities with potential neurosurgical utility are also analyzed. Methods: A comprehensive literature search was performed utilizing PubMed and key words: In vivo confocal microscopy, confocal endomicroscopy, fluorescence imaging, in vivo diagnostics/neoplasm, in vivo molecular imaging, and optical imaging. Articles were reviewed that discussed clinically available fluorophores in neurosurgery, confocal endomicroscopy instrumentation, confocal microscopy systems, and intraoperative cancer diagnostics. Results: Current clinically available fluorescent contrast agents have specific properties that provide microscopic delineation of tumors when imaged with laser scanning confocal endomicroscopes. Other imaging modalities such as coherent anti-Stokes Raman scattering (CARS) microscopy, confocal reflectance microscopy, fluorescent lifetime imaging (FLIM), two-photon microscopy, and second harmonic generation may also have potential in neurosurgical applications. Conclusion: In addition to guiding tumor resection, intraoperative fluorescence and microscopy have the potential to facilitate tumor identification and complement frozen section analysis during surgery by providing real-time histological assessment. Further research, including clinical trials, is necessary to test the efficacy of fluorescent contrast agents and optical imaging instrumentation in order to establish their role in neurosurgery. PMID:24872922

  5. Ultrasmall Nanoplatforms as Calcium-Responsive Contrast Agents for Magnetic Resonance Imaging.

    PubMed

    Moussaron, Albert; Vibhute, Sandip; Bianchi, Andrea; Gündüz, Serhat; Kotb, Shady; Sancey, Lucie; Motto-Ros, Vincent; Rizzitelli, Silvia; Crémillieux, Yannick; Lux, Francois; Logothetis, Nikos K; Tillement, Olivier; Angelovski, Goran

    2015-10-01

    The preparation of ultrasmall and rigid platforms (USRPs) that are covalently coupled to macrocycle-based, calcium-responsive/smart contrast agents (SCAs), and the initial in vitro and in vivo validation of the resulting nanosized probes (SCA-USRPs) by means of magnetic resonance imaging (MRI) is reported. The synthetic procedure is robust, allowing preparation of the SCA-USRPs on a multigram scale. The resulting platforms display the desired MRI activity—i.e., longitudinal relaxivity increases almost twice at 7 T magnetic field strength upon saturation with Ca(2+). Cell viability is probed with the MTT assay using HEK-293 cells, which show good tolerance for lower contrast agent concentrations over longer periods of time. On intravenous administration of SCA-USRPs in living mice, MRI studies indicate their rapid accumulation in the renal pelvis and parenchyma. Importantly, the MRI signal increases in both kidney compartments when CaCl2 is also administrated. Laser-induced breakdown spectroscopy experiments confirm accumulation of SCA-USRPs in the renal cortex. To the best of our knowledge, these are the first studies which demonstrate calcium-sensitive MRI signal changes in vivo. Continuing contrast agent and MRI protocol optimizations should lead to wider application of these responsive probes and development of superior functional methods for monitoring calcium-dependent physiological and pathological processes in a dynamic manner. PMID:26179212

  6. Protein MRI contrast agent with unprecedented metal selectivity and sensitivity for liver cancer imaging

    PubMed Central

    Yang, Hua; Qiao, Jingjuan; Pu, Fan; Jiang, Jie; Hubbard, Kendra; Hekmatyar, Khan; Langley, Jason; Salarian, Mani; Long, Robert C.; Bryant, Robert G.; Hu, Xiaoping Philip; Grossniklaus, Hans E.; Liu, Zhi-Ren; Yang, Jenny J.

    2015-01-01

    With available MRI techniques, primary and metastatic liver cancers that are associated with high mortality rates and poor treatment responses are only diagnosed at late stages, due to the lack of highly sensitive contrast agents without Gd3+ toxicity. We have developed a protein contrast agent (ProCA32) that exhibits high stability for Gd3+ and a 1011-fold greater selectivity for Gd3+ over Zn2+ compared with existing contrast agents. ProCA32, modified from parvalbumin, possesses high relaxivities (r1/r2: 66.8 mmol−1⋅s−1/89.2 mmol−1⋅s−1 per particle). Using T1- and T2-weighted, as well as T2/T1 ratio imaging, we have achieved, for the first time (to our knowledge), robust MRI detection of early liver metastases as small as ∼0.24 mm in diameter, much smaller than the current detection limit of 10–20 mm. Furthermore, ProCA32 exhibits appropriate in vivo preference for liver sinusoidal spaces and pharmacokinetics for high-quality imaging. ProCA32 will be invaluable for noninvasive early detection of primary and metastatic liver cancers as well as for monitoring treatment and guiding therapeutic interventions, including drug delivery. PMID:25971726

  7. Development of Ultrasound-switchable Fluorescence Imaging Contrast Agents based on Thermosensitive Polymers and Nanoparticles

    PubMed Central

    Cheng, Bingbing; Wei, Ming-Yuan; Liu, Yuan; Pitta, Harish; Xie, Zhiwei; Hong, Yi; Nguyen, Kytai T.; Yuan, Baohong

    2015-01-01

    In this work we first introduced a recently developed high-resolution, deep-tissue imaging technique, ultrasound-switchable fluorescence (USF). The imaging principles based on two types of USF contrast agents were reviewed. To improve USF imaging techniques further, excellent USF contrast agents were developed based on high-performance thermoresponsive polymers and environment-sensitive fluorophores. Herein, such contrast agents were synthesized and characterized with five key parameters: (1) peak excitation and emission wavelengths (λex and λem), (2) the fluorescence intensity ratio between on and off states (IOn/IOff), (3) the fluorescence lifetime ratio between on and off states (τOn/τOff), (4) the temperature threshold to switch on fluorophores (Tth), and (5) the temperature transition bandwidth (TBW). We mainly investigated fluorescence intensity and lifetime changes of four environment-sensitive dyes [7-(2-Aminoethylamino)-N,N-dimethyl-4-benzofurazansulfonamide (DBD-ED), St633, Sq660, and St700] as a function of temperature, while the dye was attached to poly(N-isopropylacrylamide) linear polymers or encapsulated in nanoparticles. Six fluorescence resonance energy transfer systems were invented in which both the donor (DBD-ED or ST425) and the acceptor (Sq660) were adopted. Our results indicate that three Förster resonance energy transfer systems, where both IOn/IOff and τOn/τOff are larger than 2.5, are promising for application in future surface tissue bioimaging by USF technique. PMID:26052192

  8. Preserving Enhancement in Freeze-Dried Contrast Agent ST68: Examination of Excipients

    PubMed Central

    Solis, Carl; Forsberg, Flemming; Wheatley, Margaret A.

    2013-01-01

    The perfluorcarbon (perfluorobutane) ultrasound contrast agent ST68, composed of sonicated mixtures of non-ionic surfactants, is stable in solution for only a few weeks at 4°C. Freeze-drying critically diminished ST68’s ability to reflect ultrasound (its echogenicity). A method of incorporating specific lyoprotectants before lyophilization was investigated. Reintroduction of perfluorobutane to the protected freeze-dried sample, followed by reconstituting with preserved echogenicity. Glucose, trehalose, sucrose, and mannitol were tested at 100 mM and in vitro echogenicity data was collected from samples with dose concentrations of 50 µl/l to 300 µl/l. Glucose was found to be the best lyoprotectant providing an average (n=3) maximum peak enhancement of 23.2 ± 1.2 dB in vitro, measured at 5 MHz, 684 kPa, and a pulse repetition frequency (PRF) of 100 Hz (p<0.05 over freeze-dried ST68 control) and 20.8 ± 0.8 dB in vivo in New Zealand white rabbits at 5 MHz and a PRF of 6.7 kHz. Pulse inversion harmonic US images of a rabbit kidney, pre- and post-contrast injection (0.1 ml/kg), showed excellent enhancement and clear vascular delineation, similar to that of the original agent. For the first time this contrast agent can be successfully freeze-dried yielding a longer self-life without the need for refrigeration. PMID:20540998

  9. Physical characteristics of lanthanide complexes that act as magnetization transfer (MT) contrast agents

    NASA Astrophysics Data System (ADS)

    Zhang, Shanrong; Sherry, A. Dean

    2003-02-01

    Rapid water exchange is normally considered a prerequisite for efficient Gd 3+-based MRI contrast agents. Yet recent measures of exchange rates in some Gd 3+ complexes have shown that water exchange can become limiting when such complexes are attached to larger macromolecular structures. A new class of lanthanide complexes that display unusually slow water exchange (bound water lifetimes ( τM298) > 10 μs) has recently been reported. This apparent disadvantage may be taken advantage of by switching the metal ion from gadolinium(III) to a lanthanide that shifts the bound water resonance substantially away from bulk water. Given appropriate water exchange kinetics, one can then alter the intensity of the bulk water signal by selective presaturation of this highly shifted, Ln3+-bound water resonance. This provides the basis of a new method to alter MR image contrast in tissue. We have synthesized a variety of DOTA-tetra(amide) ligands to evaluate as potential magnetization transfer (MT) contrast agents and found that the bound water lifetimes in these complexes are sensitive to both ligand structure (a series of Eu 3+ complexes have τM298 values that range from 1 to 1300 μs) and the identity of the paramagnetic Ln3+ cation (from 3 to 800 μs for a single ligand). This demonstrates that it may be possible either to fine-tune the ligand structure or to select proper lanthanide cation to create an optimal MT agent for any clinical imaging field.

  10. Novel receptor-targeted contrast agents for optical imaging of tumors

    NASA Astrophysics Data System (ADS)

    Becker, Andreas; Hessenius, Carsten; Bhargava, Sarah; Ebert, Bernd; Sukowski, Uwe; Rinneberg, Herbert H.; Wiedenmann, Bertram; Semmler, Wolfhard; Licha, Kai

    2000-04-01

    Many gastroenteropancreatic tumors express receptors for somatostatin (SST) and/or vasoactive intestinal peptide (VIP). These receptors can be used as molecular targets for the delivery of contrast agents for tumor diagnostics. We have synthesized conjugates consisting of a cyanine dye and an SST analogue or VIP for use as contrast agents in optical imaging. Receptor binding and internalization of these compounds were examined with optical methods in transfected RIN38 tumor cells expressing the SST2 receptor or a GFP- labeled VIP (VPAC1) receptor. Furthermore, biodistribution of the conjugates was examined by laser-induced fluorescence imaging in nude mice bearing SST2 or VPAC1 receptor- expressing tumors. After incubation of RIN38 SSTR2 cells in the presence of 100 nM indotricarbocyanine-SST analogue, cell-associated fluorescence increased, whereas no increase was observed when receptor-medicated endocytosis was inhibited. Indodicarbocyanine-VIP accumulated in RIN38 VPAC1 cells and co-localization with the GFP-labeled VPAC1 receptor was observed. After injection of indotricarbocyanine-SST analogue into tumor-bearing nude mice, SST2 receptor-positive tumors could be visualized for a time period from 10 min to at least 48 h. After application of indodicarbocyanine-VIP, a fluorescence signal in VIP1 receptor-expressing tumors was only detected during the first hour. We conclude that cyanine dye-labeled VIP and SST analogue are novel, targeted contrast agents for the optical imaging of tumors expressing the relevant receptor.

  11. Open-Source Automated Parahydrogen Hyperpolarizer for Molecular Imaging Using (13)C Metabolic Contrast Agents.

    PubMed

    Coffey, Aaron M; Shchepin, Roman V; Truong, Milton L; Wilkens, Ken; Pham, Wellington; Chekmenev, Eduard Y

    2016-08-16

    An open-source hyperpolarizer producing (13)C hyperpolarized contrast agents using parahydrogen induced polarization (PHIP) for biomedical and other applications is presented. This PHIP hyperpolarizer utilizes an Arduino microcontroller in conjunction with a readily modified graphical user interface written in the open-source processing software environment to completely control the PHIP hyperpolarization process including remotely triggering an NMR spectrometer for efficient production of payloads of hyperpolarized contrast agent and in situ quality assurance of the produced hyperpolarization. Key advantages of this hyperpolarizer include: (i) use of open-source software and hardware seamlessly allowing for replication and further improvement as well as readily customizable integration with other NMR spectrometers or MRI scanners (i.e., this is a multiplatform design), (ii) relatively low cost and robustness, and (iii) in situ detection capability and complete automation. The device performance is demonstrated by production of a dose (∼2-3 mL) of hyperpolarized (13)C-succinate with %P13C ∼ 28% and 30 mM concentration and (13)C-phospholactate at %P13C ∼ 15% and 25 mM concentration in aqueous medium. These contrast agents are used for ultrafast molecular imaging and spectroscopy at 4.7 and 0.0475 T. In particular, the conversion of hyperpolarized (13)C-phospholactate to (13)C-lactate in vivo is used here to demonstrate the feasibility of ultrafast multislice (13)C MRI after tail vein injection of hyperpolarized (13)C-phospholactate in mice. PMID:27478927

  12. Chitosan-coated nickel-ferrite nanoparticles as contrast agents in magnetic resonance imaging

    NASA Astrophysics Data System (ADS)

    Ahmad, Tanveer; Bae, Hongsub; Iqbal, Yousaf; Rhee, Ilsu; Hong, Sungwook; Chang, Yongmin; Lee, Jaejun; Sohn, Derac

    2015-05-01

    We report evidence for the possible application of chitosan-coated nickel-ferrite (NiFe2O4) nanoparticles as both T1 and T2 contrast agents in magnetic resonance imaging (MRI). The coating of nickel-ferrite nanoparticles with chitosan was performed simultaneously with the synthesis of the nickel-ferrite nanoparticles by a chemical co-precipitation method. The coated nanoparticles were cylindrical in shape with an average length of 17 nm and an average width of 4.4 nm. The bonding of chitosan onto the ferrite nanoparticles was confirmed by Fourier transform infrared spectroscopy. The T1 and T2 relaxivities were 0.858±0.04 and 1.71±0.03 mM-1 s-1, respectively. In animal experimentation, both a 25% signal enhancement in the T1-weighted mage and a 71% signal loss in the T2-weighted image were observed. This demonstrated that chitosan-coated nickel-ferrite nanoparticles are suitable as both T1 and T2 contrast agents in MRI. We note that the applicability of our nanoparticles as both T1 and T2 contrast agents is due to their cylindrical shape, which gives rise to both inner and outer sphere processes of nanoparticles.

  13. Dual targeting improves microbubble contrast agent adhesion to VCAM-1 and P-selectin under flow

    PubMed Central

    Ferrante, E. A.; Pickard, J. E.; Rychak, J.; Klibanov, A.; Ley, K.

    2009-01-01

    To improve ultrasound contrast agents targeted to the adhesion molecules P-selectin and VCAM-1 for the purpose of molecular imaging of atherosclerotic plaques, perfluorocarbon-filled phospholipid microbubble contrast agents were coupled by a polyethylene glycol-biotin-streptavidin bridge with mAb MVCAM.A(429), a sialyl Lewisx polymer (PAA-sLex), or both (dual). Approximately three hundred thousand antibody molecules were coupled to the surface of each microbubble. Recombinant mouse P-selectin and/or VCAM-1 coated on flow chambers showed saturation of binding at approximately 15 ng/μl, resulting in 800 and 1200 molecules/μm2 for P-selectin and VCAM-1, respectively. Dual substrates coated with equal concentrations of P-selectin and VCAM-1 had site densities between 50 and 60% of single substrates. When microbubbles were perfused through flow chambers at 5×106 microbubbles/ml (wall shear stress from 1.5 to 6 dyn/cm2) dual targeted microbubbles adhered almost twice as efficiently as single targeted microbubbles at 6 dyn/cm2. The present study suggests that dual targeted contrast agents may be useful for atherosclerotic plaque detection at physiologically relevant shear stresses. PMID:19666063

  14. Peptidyl Molecular Imaging Contrast Agents Using a New Solid Phase Peptide Synthesis Approach

    PubMed Central

    Yoo, Byunghee; Pagel, Mark D.

    2008-01-01

    A versatile method is disclosed for solid phase peptide synthesis (SPPS) of molecular imaging contrast agents. A DO3A moiety was derivatized to introduce a CBZ-protected amino group and then coupled to a polymeric support. CBZ cleavage with Et2AlCl/thioanisole was optimized for SPPS. Amino acids were then coupled to the aminoDOTA loaded resin using conventional step-wise Fmoc SPPS to create a product with DOTA coupled to the C-terminus of the peptide. In a second study, the DO3A moiety was coupled to a glycine-loaded polymeric support, and amino acids were then coupled to the amino-DOTA-peptide loaded resin using SPPS, to incorporate DOTA within the peptide sequence. The peptide-(Tm3+-DOTA) amide showed a PARAmagnetic Chemical Exchange Saturation Transfer (PARACEST) effect, which demonstrated the utility of this contrast agent for molecular imaging. These results demonstrate the advantages of exploiting SPPS methodologies through the development of unique DOTA derivatives to create peptide-based molecular imaging contrast agents. PMID:17330953

  15. NIR-activated iron oxides as a new multi-functional contrast agent of photoacoustic imaging

    NASA Astrophysics Data System (ADS)

    Ting, Pei-Hsien; Huang, Chih-Chia; Li, Meng-Lin

    2014-03-01

    Iron oxide nanoparticles are commonly used contrast agents for theranostic nanomedicines because of their advantages of good biocompatibility, high stability in physiological conditions, low cytotoxicity and excellent safety record in clinical settings for human use. In this study, we developed a NIR-activated iron oxide (NIR-Fe3O4) nanoparticle as a new multi-functional contrast agent of photoacoustic (PA) imaging. Unlike traditional iron oxides, the developed NIR-Fe3O4 owns biocompatibility and optical tunability capable of providing strong optical absorption in the NIR range for PA signal generation. Its intrinsic magnetic property enables the active magnetic tumor targeting. Phantom experiments were performed to confirm the tunability of NIR-Fe3O4's optical absorption in NIR and demonstrate its magnetic targeting capability. The PA signal response of NIR-Fe3O4 as a function of concentration was also investigated. The results showed that the PA signal of NIR-Fe3O4 with OD=1.25 was comparable to that of blood at 715 nm - the wavelength of peak absorption of the used NIR-Fe3O4. Moreover, the PA signal from NIR-Fe3O4 could be further improved by magnetic targeting. Overall, we proved that the potential of the developed NIR-Fe3O4 as a good tumor targeting contrast agent of PA imaging.

  16. The fabrication of novel nanobubble ultrasound contrast agent for potential tumor imaging

    NASA Astrophysics Data System (ADS)

    Xing, Zhanwen; Wang, Jinrui; Ke, Hengte; Zhao, Bo; Yue, Xiuli; Dai, Zhifei; Liu, Jibin

    2010-04-01

    Novel biocompatible nanobubbles were fabricated by ultrasonication of a mixture of Span 60 and polyoxyethylene 40 stearate (PEG40S) followed by differential centrifugation to isolate the relevant subpopulation from the parent suspensions. Particle sizing analysis and optical microscopy inspection indicated that the freshly generated micro/nanobubble suspension was polydisperse and the size distribution was bimodal with large amounts of nanobubbles. To develop a nano-sized contrast agent that is small enough to leak through tumor pores, a fractionation to extract smaller bubbles by variation in the time of centrifugation at 20g (relative centrifuge field, RCF) was suggested. The results showed that the population of nanobubbles with a precisely controlled mean diameter could be sorted from the initial polydisperse suspensions to meet the specified requirements. The isolated bubbles were stable over two weeks under the protection of perfluoropropane gas. The acoustic behavior of the nano-sized contrast agent was evaluated using power Doppler imaging in a normal rabbit model. An excellent power Doppler enhancement was found in vivo renal imaging after intravenous injection of the obtained nanobubbles. Given the broad spectrum of potential clinical applications, the nano-sized contrast agent may provide a versatile adjunct for ultrasonic imaging enhancement and/or treatment of tumors.

  17. The fabrication of novel nanobubble ultrasound contrast agent for potential tumor imaging.

    PubMed

    Xing, Zhanwen; Wang, Jinrui; Ke, Hengte; Zhao, Bo; Yue, Xiuli; Dai, Zhifei; Liu, Jibin

    2010-04-01

    Novel biocompatible nanobubbles were fabricated by ultrasonication of a mixture of Span 60 and polyoxyethylene 40 stearate (PEG40S) followed by differential centrifugation to isolate the relevant subpopulation from the parent suspensions. Particle sizing analysis and optical microscopy inspection indicated that the freshly generated micro/nanobubble suspension was polydisperse and the size distribution was bimodal with large amounts of nanobubbles. To develop a nano-sized contrast agent that is small enough to leak through tumor pores, a fractionation to extract smaller bubbles by variation in the time of centrifugation at 20g (relative centrifuge field, RCF) was suggested. The results showed that the population of nanobubbles with a precisely controlled mean diameter could be sorted from the initial polydisperse suspensions to meet the specified requirements. The isolated bubbles were stable over two weeks under the protection of perfluoropropane gas. The acoustic behavior of the nano-sized contrast agent was evaluated using power Doppler imaging in a normal rabbit model. An excellent power Doppler enhancement was found in vivo renal imaging after intravenous injection of the obtained nanobubbles. Given the broad spectrum of potential clinical applications, the nano-sized contrast agent may provide a versatile adjunct for ultrasonic imaging enhancement and/or treatment of tumors. PMID:20220227

  18. Biocompatibility of ferritin-based nanoparticles as targeted MRI contrast agents.

    PubMed

    Charlton, Jennifer R; Pearl, Valeria M; Denotti, Anna R; Lee, Jonathan B; Swaminathan, Sundararaman; Scindia, Yogesh M; Charlton, Nathan P; Baldelomar, Edwin J; Beeman, Scott C; Bennett, Kevin M

    2016-08-01

    Ferritin is a naturally occurring iron storage protein, proposed as a clinically relevant nanoparticle with applications as a diagnostic and therapeutic agent. Cationic ferritin is a targeted, injectable contrast agent to measure kidney microstructure with MRI. Here, the toxicity of horse spleen ferritin is assessed as a step to clinical translation. Adult male mice received cationic, native and high dose cationic ferritin (CF, NF, or HDCF) or saline and were monitored for 3weeks. Transient weight loss occurred in the ferritin groups with no difference in renal function parameters. Ferritin-injected mice demonstrated a lower serum iron 3weeks after administration. In ferritin-injected animals pre-treated with hydrocortisone, there were no structural or weight differences in the kidneys, liver, lung, heart, or spleen. This study demonstrates a lack of significant detrimental effects of horse-derived ferritin-based nanoparticles at MRI-detectable doses, allowing further exploration of these agents in basic research and clinical diagnostics. PMID:27071333

  19. Current status of superparamagnetic iron oxide contrast agents for liver magnetic resonance imaging.

    PubMed

    Wang, Yi-Xiang J

    2015-12-21

    Five types of superparamagnetic iron oxide (SPIO), i.e. Ferumoxides (Feridex(®) IV, Berlex Laboratories), Ferucarbotran (Resovist(®), Bayer Healthcare), Ferumoxtran-10 (AMI-227 or Code-7227, Combidex(®), AMAG Pharma; Sinerem(®), Guerbet), NC100150 (Clariscan(®), Nycomed,) and (VSOP C184, Ferropharm) have been designed and clinically tested as magnetic resonance contrast agents. However, until now Resovist(®) is current available in only a few countries. The other four agents have been stopped for further development or withdrawn from the market. Another SPIO agent Ferumoxytol (Feraheme(®)) is approved for the treatment of iron deficiency in adult chronic kidney disease patients. Ferumoxytol is comprised of iron oxide particles surrounded by a carbohydrate coat, and it is being explored as a potential imaging approach for evaluating lymph nodes and certain liver tumors. PMID:26715826

  20. Development and application of a multimodal contrast agent for SPECT/CT hybrid imaging.

    PubMed

    Criscione, Jason M; Dobrucki, Lawrence W; Zhuang, Zhen W; Papademetris, Xenophon; Simons, Michael; Sinusas, Albert J; Fahmy, Tarek M

    2011-09-21

    Hybrid or multimodality imaging is often applied in order to take advantage of the unique and complementary strengths of individual imaging modalities. This hybrid noninvasive imaging approach can provide critical information about anatomical structure in combination with physiological function or targeted molecular signals. While recent advances in software image fusion techniques and hybrid imaging systems have enabled efficient multimodal imaging, accessing the full potential of this technique requires development of a new toolbox of multimodal contrast agents that enhance the imaging process. Toward that goal, we report the development of a hybrid probe for both single photon emission computed tomography (SPECT) and X-ray computed tomography (CT) imaging that facilitates high-sensitivity SPECT and high spatial resolution CT imaging. In this work, we report the synthesis and evaluation of a novel intravascular, multimodal dendrimer-based contrast agent for use in preclinical SPECT/CT hybrid imaging systems. This multimodal agent offers a long intravascular residence time (t(1/2) = 43 min) and sufficient contrast-to-noise for effective serial intravascular and blood pool imaging with both SPECT and CT. The colocalization of the dendritic nuclear and X-ray contrasts offers the potential to facilitate image analysis and quantification by enabling correction for SPECT attenuation and partial volume errors at specified times with the higher resolution anatomic information provided by the circulating CT contrast. This may allow absolute quantification of intramyocardial blood volume and blood flow and may enable the ability to visualize active molecular targeting following clearance from the blood. PMID:21851119

  1. Dextran coated bismuth-iron oxide nanohybrid contrast agents for computed tomography and magnetic resonance imaging

    PubMed Central

    Naha, Pratap C.; Zaki, Ajlan Al; Hecht, Elizabeth; Chorny, Michael; Chhour, Peter; Blankemeyer, Eric; Yates, Douglas M.; Witschey, Walter R. T.; Litt, Harold I.; Tsourkas, Andrew; Cormode, David P.

    2014-01-01

    Bismuth nanoparticles have been proposed as a novel CT contrast agent, however few syntheses of biocompatible bismuth nanoparticles have been achieved. We herein report the synthesis of composite bismuth-iron oxide nanoparticles (BION) that are based on a clinically approved, dextran-coated iron oxide formulation; the particles have the advantage of acting as contrast agents for both CT and MRI. BION were synthesized and characterized using various analytical methods. BION CT phantom images revealed that the X-ray attenuation of the different formulations was dependent upon the amount of bismuth present in the nanoparticle, while T2-weighted MRI contrast decreased with increasing bismuth content. No cytotoxicity was observed in Hep G2 and BJ5ta cells after 24 hours incubation with BION. The above properties, as well as the yield of synthesis and bismuth inclusion efficiency, led us to select the Bi-30 formulation for in vivo experiments, performed in mice using a micro-CT and a 9.4 T MRI system. X-ray contrast was observed in the heart and blood vessels over a 2 hour period, indicating that Bi-30 has a prolonged circulation half-life. Considerable signal loss in T2-weighted MR images was observed in the liver compared to pre-injection scans. Evaluation of the biodistribution of Bi-30 revealed that bismuth is excreted via the urine, with significant concentrations found in the kidneys and urine. In vitro experiments confirmed the degradability of Bi-30. In summary, dextran coated BION are biocompatible, biodegradable, possess strong X-ray attenuation properties and also can be used as T2-weighted MR contrast agents. PMID:25485115

  2. Multispectral photoacoustic decomposition with localized regularization for detecting targeted contrast agent

    NASA Astrophysics Data System (ADS)

    Tavakoli, Behnoosh; Chen, Ying; Guo, Xiaoyu; Kang, Hyun Jae; Pomper, Martin; Boctor, Emad M.

    2015-03-01

    Targeted contrast agents can improve the sensitivity of imaging systems for cancer detection and monitoring the treatment. In order to accurately detect contrast agent concentration from photoacoustic images, we developed a decomposition algorithm to separate photoacoustic absorption spectrum into components from individual absorbers. In this study, we evaluated novel prostate-specific membrane antigen (PSMA) targeted agents for imaging prostate cancer. Three agents were synthesized through conjugating PSMA-targeting urea with optical dyes ICG, IRDye800CW and ATTO740 respectively. In our preliminary PA study, dyes were injected in a thin wall plastic tube embedded in water tank. The tube was illuminated with pulsed laser light using a tunable Q-switch ND-YAG laser. PA signal along with the B-mode ultrasound images were detected with a diagnostic ultrasound probe in orthogonal mode. PA spectrums of each dye at 0.5 to 20 μM concentrations were estimated using the maximum PA signal extracted from images which are obtained at illumination wavelengths of 700nm-850nm. Subsequently, we developed nonnegative linear least square optimization method along with localized regularization to solve the spectral unmixing. The algorithm was tested by imaging mixture of those dyes. The concentration of each dye was estimated with about 20% error on average from almost all mixtures albeit the small separation between dyes spectrums.

  3. Fluorescent and scattering contrast agents in a mouse model of colorectal cancer

    NASA Astrophysics Data System (ADS)

    Winkler, Amy M.; Rice, Photini F. S.; Troutman, Timothy S.; Backer, Marina V.; Backer, Joseph M.; Drezek, Rebekah A.; Romanowski, Marek; Barton, Jennifer K.

    2008-02-01

    In previous work we have demonstrated the utility of laser-induced fluorescence (LIF) and optical coherence tomography (OCT) to identify adenoma in mouse models of colorectal cancer with high sensitivity and specificity. However, improved sensitivity to early disease, as well as the ability to distinguish confounders (e.g. fecal contamination, natural variations in mucosal thickness), is desired. In this study, we investigated the signal enhancement of fluorescent and scattering contrast agents in the colons of AOM-treated mice. The fluorescent tracer scVEGF/Cy, targeted to receptors for vascular endothelial growth factor, was visualized on a dual modality OCT/LIF endoscopic system with 1300-nm center wavelength OCT source and 635-nm LIF excitation. Scattering agents were tested with an 890-nm center wavelength endoscopic OCT system. Agents included nanoshells, 120-nm in diameter, and nanorods, 20-nm in diameter by 80-nm in length. Following imaging, colons were excised. Tissue treated with fluorophore was imaged on an epifluorescence microscope. Histological sections were obtained and stained with H&E and silver enhancer to verify disease and identify regions of gold uptake, respectively. Non-specific signal enhancement was observed with the scattering contrast agents. Specificity for adenoma was seen with the scVEGF/Cy dye.

  4. Pump-probe optical coherence tomography using microencapsulated methylene blue as a contrast agent (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Kim, Wihan; Zebrowski, Erin; Lopez, Hazel C.; Applegate, Brian E.; Charoenphol, Phapanin; Jo, Javier A.

    2016-03-01

    Molecular contrast imaging can target specific molecules or receptors to provide detailed information on the local biochemistry and yield enhanced visualization of pathological and physiological processes. When paired with Optical Coherence Tomography (OCT) it can simultaneously supply the morphological context for the molecular information. We recently demonstrated in vivo molecular contrast imaging of methylene blue (MB) using a 663 nm diode laser as a pump in a Pump-Probe OCT (PPOCT) system. The simple addition of a dichroic mirror in the sample arm enabled PPOCT imaging with a typical 830-nm band spectral-domain OCT system. Here we report on the development of a microencapsulated MB contrast agent. The poly lactic-co-glycolic acid (PLGA) microspheres loaded with MB offer several advantages over bare MB. The microsphere encapsulation improves the PPOCT signal both by enhancing the scattering and preventing the reduction of MB to leucomethylene blue. The surface of the microsphere can readily be functionalized to enable active targeting of the contrast agent without modifying the excited state dynamics of MB that enable PPOCT imaging. Both MB and PLGA are used clinically. PLGA is FDA approved and used in drug delivery and tissue engineering applications. 2.5 μm diameter microspheres were synthesized with an inner core containing 0.01% (w/v) aqueous MB. As an initial demonstration the MB microspheres were imaged in a 100 μm diameter capillary tube submerged in a 1% intralipid emulsion.

  5. The effects of acoustic radiation force on contrast agents: Experimental and theoretial analysis

    NASA Astrophysics Data System (ADS)

    Dayton, Paul Alexander

    The goal of this research is to understand the response of ultrasound contrast agents to acoustic radiation force. Ultrasound contrast agents are encapsulated microbubbles similar in size and rheologic behavior to human erythrocytes. A core of either air or a high- molecular weight gas makes these microbubbles extremely compressible and highly echogenic. Clinically, the detection of blood is difficult without contrast agents because the echoes from blood cells are typically 30-40 dB less than tissue echoes. Ultrasound contrast agents have been shown to be extremely useful in assisting delineation of perfused tissue in echocardiography, and are being increasingly used for tumor detection in radiology. The high compressibility of gas-filled contrast agents makes these microbubbles susceptible to translation due to radiation force. Thus, it is important to understand the effects of this force in order to avoid erroneous measurements based on the location and flow velocity of microbubbles. In addition, the ability to displace and concentrate microbubbles may be an advantage in targeted imaging, targeted therapy, or industrial applications where it is desired to localize microbubbles in a region. In this study, experimental and theoretical tools are combined to investigate the interaction between microbubbles and an acoustic pulse. Several unique experimental systems allow visualization and analysis of the radius-time curves of individual microbubbles, the displacement of individual microbubbles in-vitro, and the displacement of microbubbles in-vivo. Theoretical analysis illustrates that the effect of radiation force on microbubbles is directly proportional to the product of the bubble volume and the acoustic pressure gradient. A model designed to simulate the radius-time behavior of individual microbubbles is verified from experimental data, and used to estimate the magnitude of radiation force. The resulting bubble translation is determined using a second model

  6. Strategies for Optimizing Water-Exchange Rates of Lanthanide-Based Contrast Agents for Magnetic Resonance Imaging

    PubMed Central

    Siriwardena-Mahanama, Buddhima N.; Allen, Matthew J.

    2013-01-01

    This review describes recent advances in strategies for tuning the water-exchange rates of contrast agents for magnetic resonance imaging (MRI). Water-exchange rates play a critical role in determining the efficiency of contrast agents; consequently, optimization of water-exchange rates, among other parameters, is necessary to achieve high efficiencies. This need has resulted in extensive research efforts to modulate water-exchange rates by chemically altering the coordination environments of the metal complexes that function as contrast agents. The focus of this review is coordination-chemistry-based strategies used to tune the water-exchange rates of lanthanide(III)-based contrast agents for MRI. Emphasis will be given to results published in the 21st century, as well as implications of these strategies on the design of contrast agents. PMID:23921796

  7. Contrast agent comparison for three-dimensional micro-CT angiography: A cadaveric study.

    PubMed

    Kingston, Mitchell J; Perriman, Diana M; Neeman, Teresa; Smith, Paul N; Webb, Alexandra L

    2016-07-01

    Barium sulfate and lead oxide contrast media are frequently used for cadaver-based angiography studies. These contrast media have not previously been compared to determine which is optimal for the visualisation and measurement of blood vessels. In this study, the lower limb vessels of 16 embalmed Wistar rats, and four sets of cannulae of known diameter, were injected with one of three different contrast agents (barium sulfate and resin, barium sulfate and gelatin, and lead oxide combined with milk powder). All were then scanned using micro-computed tomography (CT) angiography and 3-D reconstructions generated. The number of branching generations of the rat lower limb vessels were counted and compared between the contrast agents using ANOVA. The diameter of the contrast-filled cannulae, were measured and used to calculate the accuracy of the measurements by comparing the bias and variance of the estimates. Intra- and inter-observer reliability were calculated using intra-class correlation coefficients. There was no significant difference (mean difference [MD] 0.05; MD 95% confidence interval [CI] -0.83 to 0.93) between the number of branching generations for barium sulfate-resin and lead oxide-milk powder. Barium sulfate-resin demonstrated less bias and less variance of the estimates (MD 0.03; standard deviation [SD] 1.96 mm) compared to lead oxide-milk powder (MD 0.11; SD 1.96 mm) for measurements of contrast-filled cannulae scanned at high resolution. Barium sulfate-resin proved to be more accurate than lead oxide-milk powder for high resolution micro-CT scans and is preferred due to its non-toxicity. This technique could be applied to any embalmed specimen model. Copyright © 2016 John Wiley & Sons, Ltd. PMID:27075920

  8. Evaluation of chirp reversal power modulation sequence for contrast agent imaging

    NASA Astrophysics Data System (ADS)

    Novell, A.; Sennoga, CA; Escoffre, JM; Chaline, J.; Bouakaz, A.

    2014-09-01

    Over the last decade, significant research effort has been focused on the use of chirp for contrast agent imaging because chirps are known to significantly increase imaging contrast-to-noise ratio (CNR). New imaging schemes, such as chirp reversal (CR), have been developed to improve contrast detection by increasing non-linear microbubble responses. In this study we evaluated the contrast enhancement efficiency of various chirped imaging sequences in combination with well-established imaging schemes such as power modulation (PM) and pulse inversion (PI). The imaging schemes tested were implemented on a fully programmable open scanner and evaluated by ultrasonically scanning (excitation frequency of 2.5 MHz amplitude of 350 kPa) a tissue-mimicking flow phantom comprising a 4 mm diameter tube through which aqueous dispersions (dilution fraction of 1/2000) of the commercial ultrasound contrast agent, SonoVue® were continuously circulated. The recovery of non-linear microbubble responses after chirp compression requires the development and the optimization of a specific filter. A compression filter was therefore designed and used to compress and extract several non-linear components from the received microbubble responses. The results showed that using chirps increased the image CNR by approximately 10 dB, as compared to conventional Gaussian apodized sine burst excitation but degraded the axial resolution by a factor of 1.4, at -3 dB. We demonstrated that the highest CNR and contrast-to-noise ratio (CTR) were achievable when CR was combined with PM as compared to other imaging schemes such as PI.

  9. Highly monodisperse low-magnetization magnetite nanocubes as simultaneous T1-T2 MRI contrast agents

    NASA Astrophysics Data System (ADS)

    Sharma, V. K.; Alipour, A.; Soran-Erdem, Z.; Aykut, Z. G.; Demir, H. V.

    2015-06-01

    We report the first study of highly monodisperse and crystalline iron oxide nanocubes with sub-nm controlled size distribution (9.7 +/- 0.5 nm in size) that achieve simultaneous contrast enhancement in both T1- and T2-weighted magnetic resonance imaging (MRI). Here, we confirmed the magnetite structure of iron oxide nanocubes by X-ray diffraction (XRD), selected area electron diffraction (SAED) pattern, optical absorption and Fourier transformed infrared (FT-IR) spectra. These magnetite nanocubes exhibit superparamagnetic and paramagnetic behavior simultaneously by virtue of their finely controlled shape and size. The magnetic measurements reveal that the magnetic moment values are favorably much lower because of the small size and cubic shape of the nanoparticles, which results in an enhanced spin canting effect. As a proof-of-concept demonstration, we showed their potential as dual contrast agents for both T1- and T2-weighted MRI via phantom studies, in vivo imaging and relaxivity measurements. Therefore, these low-magnetization magnetite nanocubes, while being non-toxic and bio-compatible, hold great promise as excellent dual-mode T1 and T2 contrast agents for MRI.We report the first study of highly monodisperse and crystalline iron oxide nanocubes with sub-nm controlled size distribution (9.7 +/- 0.5 nm in size) that achieve simultaneous contrast enhancement in both T1- and T2-weighted magnetic resonance imaging (MRI). Here, we confirmed the magnetite structure of iron oxide nanocubes by X-ray diffraction (XRD), selected area electron diffraction (SAED) pattern, optical absorption and Fourier transformed infrared (FT-IR) spectra. These magnetite nanocubes exhibit superparamagnetic and paramagnetic behavior simultaneously by virtue of their finely controlled shape and size. The magnetic measurements reveal that the magnetic moment values are favorably much lower because of the small size and cubic shape of the nanoparticles, which results in an enhanced spin

  10. Comparative Study of Pineapple Juice as a Negative Oral Contrast Agent in Magnetic Resonance Cholangiopancreatography

    PubMed Central

    2015-01-01

    Objectives: The aim of this study was to compare the image quality of magnetic resonance Cholangiopancreatography (MRCP) using Pineapple Juice (PJ) or ranitidine as negative oral contrast agents and no agent. Materials and Methods: MRCP images of patients administered PJ (n = 117) or Ranitidine (n = 110) at random, and patients without an agent (n = 50) were evaluated. The subjective image quality of the overall, extra hepatic bile duct and pancreatic duct and the degree of elimination of gastrointestinal fluid were scored by two blinded radiologists. Results were compared using Mann-Whitney’s U-test. Results: The degrees of elimination of gastro duodenal fluid of PJ and ranitidine were significantly better than those without an agent (p < 0.01 and p < 0.01, respectively). The subjective image quality of PJ of the overall and extra hepatic bile duct were significantly better, although no significant differences for ranitidine were observed compared with those without an agent (p < 0.01 and p =0.23, p = 0.025 and p = 0.18). There were no significant differences for the pancreatic duct (p = 0.13 and p = 0.20), nor were there any significant differences in the evaluations between PJ and ranitidine (p = 0.21 and p = 0.96). Conclusion: PJ showed better performance compared to that of conventional ranitidine in terms of pancreatic and biliary depiction and safety. PMID:25738055

  11. Magnetic red blood cells as new contrast agents for MRI applications

    NASA Astrophysics Data System (ADS)

    Antonelli, Antonella; Sfara, Carla; Manuali, Elisabetta; Salamida, Sonia; Louin, Gaëlle; Magnani, Mauro

    2013-03-01

    Superparamagnetic iron oxide (SPIO) nanoparticles have been produced and used successfully as potent contrast agents for Magnetic Resonance Imaging (MRI). However, a significant challenge associated with the biological application of SPIO-tracer agents is their behavior in vivo since their efficacy is often compromised due to a rapid recognition and clearance by the reticuloendothelial system (RES) which limits the applicability of such compounds in MRI. The advances in nanotechnology and molecular cell biology had lead to improve stability and biocompatibility of these nanoparticles, but despite a number of efforts, the SPIO half-life in blood circulation is very short. In this contest, the potential of red blood cells (RBCs) loaded with SPIO nanoparticles as a tracer material for MRI has been investigated in order to realize a blood pool tracer with longer blood retention time. Previously, we have proposed the encapsulation into RBCs of superparamagnetic iron oxide nanoparticles carboxydextran coated, such as Resovist contrast agent. This approach led to a nanoparticle reduction in uptake by the RES, increasing the blood circulation half-life of nanoparticles. Recently, the loading procedure was applied to a new contrast agent, the P904 ultrasmall superparamagnetic iron oxide (USPIO) nanoparticles coated by hydrophilic derivatives of glucose, recently developed by Guerbet Laboratories. The results evidenced that this nanomaterial can be efficiently loaded into human and murine RBCs at concentrations ranging from 1.5 to 12 mM Fe. In vivo experiments performed in mice have showed an increased survival in the mouse vascular system of P904 encapsulated into RBCs respect to free P904 sample intravenously injected at the equivalent amounts.

  12. Generation of superparamagnetic liposomes revealed as highly efficient MRI contrast agents for in vivo imaging.

    PubMed

    Martina, Marie-Sophie; Fortin, Jean-Paul; Ménager, Christine; Clément, Olivier; Barratt, Gillian; Grabielle-Madelmont, Cécile; Gazeau, Florence; Cabuil, Valérie; Lesieur, Sylviane

    2005-08-01

    Maghemite (gamma-Fe2O3) nanocrystals stable at neutral pH and in isotonic aqueous media were synthesized and encapsulated within large unilamellar vesicles of egg phosphatidylcholine (EPC) and distearoyl-SN-glycero-3-phosphoethanolamine-N-[methoxy(poly(ethylene glycol))-2000] (DSPE-PEG(2000), 5 mol %), formed by film hydration coupled with sequential extrusion. The nonentrapped particles were removed by flash gel exclusion chromatography. The magnetic-fluid-loaded liposomes (MFLs) were homogeneous in size (195 +/- 33 hydrodynamic diameters from quasi-elastic light scattering). Iron loading was varied from 35 up to 167 Fe(III)/lipid mol %. Physical and superparamagnetic characteristics of the iron oxide particles were preserved after liposome encapsulation as shown by cryogenic transmission electron microscopy and magnetization curve recording. In biological media, MFLs were highly stable and avoided ferrofluid flocculation while being nontoxic toward the J774 macrophage cell line. Moreover, steric stabilization ensured by PEG-surface-grafting significantly reduced liposome association with the macrophages. The ratios of the transversal (r2) and longitudinal (r1) magnetic resonance (MR) relaxivities of water protons in MFL dispersions (6 < r2/r1 < 18) ranked them among the best T2 contrast agents, the higher iron loading the better the T2 contrast enhancement. Magnetophoresis demonstrated the possible guidance of MFLs by applying a magnetic field gradient. Mouse MR imaging assessed MFLs efficiency as contrast agents in vivo: MR angiography performed 24 h after intravenous injection of the contrast agent provided the first direct evidence of the stealthiness of PEG-ylated magnetic-fluid-loaded liposomes. PMID:16045355

  13. A novel functional CT contrast agent for molecular imaging of cancer

    NASA Astrophysics Data System (ADS)

    Li, Ji; Chaudhary, Ahmed; Chmura, Steven J.; Pelizzari, Charles; Rajh, Tijana; Wietholt, Christian; Kurtoglu, Metin; Aydogan, Bulent

    2010-08-01

    The purpose of this study was to investigate the feasibility of using a 2-deoxy-d-glucose (2-DG) labeled gold nanoparticle (AuNP-2-DG) as a functionally targeted computed tomography (CT) contrast agent to obtain high-resolution metabolic and anatomic information of tumor in a single CT scan. Gold nanoparticles (AuNPs) were fabricated and were conjugated with 1-DG or 2-DG. 1-DG provides an excellent comparison since it is known to interfere with the ability of the glucose transporter to recognize the sugar moiety. The human alveolar epithelial cancer cell line, A-549, was chosen for the in vitro cellular uptake assay. Three groups of cell samples were incubated with the 1-DG or 2-DG labeled AuNP and the unlabeled AuNP. Following the incubation, the cells were washed with sterile phosphate buffered saline to remove the excess AuNPs and spun using a centrifuge. The cell pellets were imaged using a microCT scanner immediately after the centrifugation. Internalization of AuNP-2-DG is verified using transmission electron microscopy imaging. Significant contrast enhancement in the cell samples incubated with the AuNP-2-DG with respect to the cell samples incubated with the unlabeled AuNP and the AuNP-1-DG was observed in multiple CT slices. Results from our in vitro experiments suggest that the AuNP-2-DG may be used as a functional CT contrast agent to provide high-resolution metabolic and anatomic information in a single CT scan. These results justify further in vitro and in vivo experiments to study the feasibility of using the AuNP-2-DG as a functional CT contrast agent in radiation therapy settings.

  14. Tunable, biodegradable gold nanoparticles as contrast agents for computed tomography and photoacoustic imaging.

    PubMed

    Cheheltani, Rabee; Ezzibdeh, Rami M; Chhour, Peter; Pulaparthi, Kumidini; Kim, Johoon; Jurcova, Martina; Hsu, Jessica C; Blundell, Cassidy; Litt, Harold I; Ferrari, Victor A; Allcock, Harry R; Sehgal, Chandra M; Cormode, David P

    2016-09-01

    Gold nanoparticles (AuNP) have been proposed for many applications in medicine. Although large AuNP (>5.5 nm) are desirable for their longer blood circulation and accumulation in diseased tissues, small AuNP (<5.5 nm) are required for excretion via the kidneys. We present a novel platform where small, excretable AuNP are encapsulated into biodegradable poly di(carboxylatophenoxy)phosphazene (PCPP) nanospheres. These larger nanoparticles (Au-PCPP) can perform their function as contrast agents, then subsequently break down into harmless byproducts and release the AuNP for swift excretion. Homogeneous Au-PCPP were synthesized using a microfluidic device. The size of the Au-PCPP can be controlled by the amount of polyethylene glycol-polylysine (PEG-PLL) block co-polymer in the formulation. Synthesis of Au-PCPP nanoparticles and encapsulation of AuNP in PCPP were evaluated using transmission electron microscopy and their biocompatibility and biodegradability confirmed in vitro. The Au-PCPP nanoparticles were found to produce strong computed tomography contrast. The UV-Vis absorption peak of Au-PCPP can be tuned into the near infrared region via inclusion of varying amounts of AuNP and controlling the nanoparticle size. In vitro and in vivo experiments demonstrated the potential of Au-PCPP as contrast agents for photoacoustic imaging. Therefore, Au-PCPP nanoparticles have high potency as contrast agents for two imaging modalities, as well as being biocompatible and biodegradable, and thus represent a platform with potential for translation into the clinic. PMID:27322961

  15. Image quality and attenuation values of multi detector CT coronary angiography using high iodine-concentration contrast material: A comparison of the use of iopromide 370 and iomeprol 400

    PubMed Central

    Kim, Eun Young; Yeh, Dae Wook; Choe, Yeon Hyeon; Lee, Won Jae; Lim, Hyo Keun

    2010-01-01

    Background: Effects of high iodine-concentration contrast material on the image quality of coronary CT angiography (CCTA) have not been well evaluated. Purpose: To compare the image quality and attenuation values of CCTA between patients administered iopromide 370 and iomeprol 400 with the use of 64-slice multidetector CT. Material and Methods: Patients were prospectively enrolled and were randomized into two groups (group A, 151 patients received iopromide 370, iodine flux = 1.48 g I/s; group B, 146 patients received iomeprol 400, iodine flux = 1.60 g I/s). CT attenuation was measured in the coronary arteries and great arteries and measurements were standardized based on an iodine flux of 1.5 0 g I/s. The image quality of 15 coronary artery segments was graded by two radiologists in consensus with the use of a four-point scale (1 = excellent to 4 = poor enhancement). Non-parametric statistical approaches were used to compare the two groups. Results: The median attenuation values in the coronary arteries were 454 HU and 464 HU for iopromide 370 and iomeprol 400, respectively, and they did not differ (P = 0.26). When standardizing for an iodine flux, significantly higher attenuation values were found for iopromide 370 (median = 460 HU, range = 216-791 HU) compared with iomeprol 400 (median = 435 HU, range = 195—758 HU) (P = 0.006). The median image quality score of coronary arterial segments was 1 (range 1—2) for both groups (P = 0.84). Conclusion: The attenuation values in the coronary arteries after injection of the same amount of two high iodine-concentration contrast materials at the same flow rate with different iodine fluxes are similar with no difference in image quality. With standardization for an iodine flux, the attenuation is significantly higher when using iopromide 370. PMID:20849317

  16. Nanoparticle-based highly sensitive MRI contrast agents with enhanced relaxivity in reductive milieu.

    PubMed

    Sigg, Severin J; Santini, Francesco; Najer, Adrian; Richard, Pascal U; Meier, Wolfgang P; Palivan, Cornelia G

    2016-08-01

    Current magnetic resonance imaging (MRI) contrast agents often produce insufficient contrast for diagnosis of early disease stages, and do not sense their biochemical environments. Herein, we report a highly sensitive nanoparticle-based MRI probe with r1 relaxivity up to 51.7 ± 1.2 mM(-1) s(-1) (3T). Nanoparticles were co-assembled from Gd(3+) complexed to heparin-poly(dimethylsiloxane) copolymer, and a reduction-sensitive amphiphilic peptide serving to induce responsiveness to environmental changes. The release of the peptide components leads to a r1 relaxivity increase under reducing conditions and increases the MRI contrast. In addition, this MRI probe has several advantages, such as a low cellular uptake, no apparent cellular toxicity (tested up to 1 mM Gd(3+)), absence of an anticoagulation property, and a high shelf stability (no increase in free Gd(3+) over 7 months). Thus, this highly sensitive T1 MRI contrast nanoparticle system represents a promising probe for early diagnosis through possible accumulation and contrast enhancement within reductive extracellular tumour tissue. PMID:27435820

  17. Linear Gadolinium-Based Contrast Agents Are Associated With Brain Gadolinium Retention in Healthy Rats

    PubMed Central

    Robert, Philippe; Violas, Xavier; Grand, Sylvie; Lehericy, Stéphane; Idée, Jean-Marc; Ballet, Sébastien; Corot, Claire

    2016-01-01

    Objectives The aim of this study was to evaluate Gd retention in the deep cerebellar nuclei (DCN) of linear gadolinium-based contrast agents (GBCAs) compared with a macrocyclic contrast agent. Materials and Methods The brain tissue retention of Gd of 3 linear GBCAs (gadobenate dimeglumine, gadopentetate dimeglumine, and gadodiamide) and a macrocyclic GBCA (gadoterate meglumine) was compared in healthy rats (n = 8 per group) that received 20 intravenous injections of 0.6 mmol Gd/kg (4 injections per week for 5 weeks). An additional control group with saline was included. T1-weighted magnetic resonance imaging was performed before injection and once a week during the 5 weeks of injections and for another 4 additional weeks after contrast period. Total gadolinium concentration was measured with inductively coupled plasma mass spectrometry. Blinded qualitative and quantitative evaluations of the T1 signal intensity in DCN were performed, as well as a statistical analysis on quantitative data. Results At completion of the injection period, all the linear contrast agents (gadobenate dimeglumine, gadopentetate dimeglumine, and gadodiamide) induced a significant increase in signal intensity in DCN, unlike the macrocyclic GBCA (gadoterate meglumine) or saline. The T1 hypersignal enhancement kinetic was fast for gadodiamide. Total Gd concentrations for the 3 linear GBCAs groups at week 10 were significantly higher in the cerebellum (1.21 ± 0.48, 1.67 ± 0.17, and 3.75 ± 0.18 nmol/g for gadobenate dimeglumine, gadopentetate dimeglumine, and gadodiamide, respectively) than with the gadoterate meglumine (0.27 ± 0.16 nmol/g, P < 0.05) and saline (0.09 ± 0.12 nmol/g, P < 0.05). No significant difference was observed between the macrocyclic agent and saline. Conclusions Repeated administrations of the linear GBCAs gadodiamide, gadobenate dimeglumine, and gadopentetate dimeglumine to healthy rats were associated with progressive and significant T1 signal hyperintensity in the

  18. Photoacoustic imaging and surface-enhanced Raman spectroscopy using dual modal contrast agents

    NASA Astrophysics Data System (ADS)

    Park, Sungjo; Lee, Seunghyun; Cha, Myeonggeun; Jeong, Cheolhwan; Kang, Homan; Park, So Yeon; Lee, Yoon-sik; Jeong, Daehong; Kim, Chulhong

    2016-03-01

    Recently, photoacoustic tomography (PAT) has emerged as a remarkable non-invasive imaging modality that provides a strong optical absorption contrast, high ultrasonic resolution, and great penetration depth. Thus, PAT has been widely used as an in vivo preclinical imaging tool. Surface-enhanced Raman spectroscopy (SERS) is another attractive sensing technology in biological research because it offers highly sensitive chemical analyses and multiplexed detection. By performing dual-modal imaging of SERS and PAT, high-resolution structural PAT imaging and high-sensitivity SERS sensing can be achieved. At the same time, it is equally important to develop a dual modal contrast agent for this purpose. To perform both PAT and SERS, we synthesized PEGylated silver bumpy nanoshells (AgBSs). The AgBSs generate strong PA signals owing to their strong optical absorption properties as well as sensitive SERS signals because of the surface plasmon resonance effect. Then, multiplexed Raman chemicals were synthesized to enhance the sensitivity of Raman. We have photoacoustically imaged the sentinel lymph nodes of small animals after intradermal injection of multiplexed agents. Furthermore, the chemical composition of each agent has been distinguished through SERS.

  19. Palladium nanosheets as highly stable and effective contrast agents for in vivo photoacoustic molecular imaging

    NASA Astrophysics Data System (ADS)

    Nie, Liming; Chen, Mei; Sun, Xiaolian; Rong, Pengfei; Zheng, Nanfeng; Chen, Xiaoyuan

    2014-01-01

    A stable and efficient contrast agent is highly desirable for photoacoustic (PA) imaging applications. Recently gold nanostructures have been widely reported and studied for PA imaging and photothermal therapy. However, the structures of the nonspherical gold nanoparticles are easily destroyed after laser irradiation and thus may fail to complete the intended tasks. In this study, we propose to apply palladium nanosheets (PNSs), with strong optical absorption in the near-infrared (NIR) region, as a new class of exogenous PA contrast agents. PA and ultrasound (US) images were acquired sequentially by a portable and fast photoacoustic tomography (PAT) system with a hand-held transducer. Significant and long-lasting imaging enhancement in SCC7 head and neck squamous cell carcinoma was successfully observed in mice by PAT over time after tail vein administration of PNSs. The morphology and functional perfusion of the tumors were delineated in PA images due to the nanoparticle accumulation. PAT of the main organs was also conducted ex vivo to trace the fate of PNSs, which was further validated by inductively coupled plasma atomic emission spectrometry (ICP-AES). No obvious toxic effect was observed by in vitro MTT assay and ex vivo histological examination 7 days after PNS administration. With the combination of a portable imaging instrument and signal specificity, PNSs might be applied as stable and effective agents for photoacoustic cancer detection, diagnosis and treatment guidance.

  20. Ultrasound modulated fluorescence emission from Pyrene-labelled liposome contrast agents

    NASA Astrophysics Data System (ADS)

    Zhang, Qimei; Moles, Matthew D.; Mather, Melissa L.; Morgan, Stephen P.

    2014-09-01

    Ultrasound modulated fluorescence tomography (USMFT) has the potential to be a useful technique to obtain fluorescence images with optical contrast and ultrasound (US) resolution in deep tissue. However, due to the intrinsic incoherent properties of fluorescence and the low modulation depth, the signal-to-noise ratio (SNR) and image contrast are poor. In this paper, the feasibility of using pyrene-labelled nanosize liposomes as contrast agents to improve the modulation depth in USMFT is investigated by using a light-scattering technique. Compared with microbubbles (MBs), which have been applied to USMFT to improve the modulation depth, liposomes are more stable and they can be manufactured with good repeatability. Also liposomes have a lower US scattering coefficient due to their liquid core as compared to the gas core of MBs, which can be advantageous when switching on fluorescence in a region of interest is required. Pyrene can form excimer fluorescence when in close proximity to other pyrene molecules. The exposure of these liposomes to US can change the collision rate of the pyrene molecules and hence modulate the optical emission. In the current work, 100 nm sized liposomes composed of varying concentrations of pyrene-labelled phospholipids were investigated to identify a suitable liposome-based US contrast agent candidate. The fluorescence emission of the pyrene-labelled liposomes insonified by continuous US were studied. It has been observed that the excimer emission from 0.5 mol% pyrene-labelled liposome is US sensitive at pressures between 1.4 MPa and 2.7 MPa. Possible fluorescence modulation mechanisms and application of pyrene-labelled liposomes for high-resolution, high-contrast fluorescence imaging are also discussed.

  1. On-chip preparation of nanoscale contrast agents towards high-resolution ultrasound imaging.

    PubMed

    Peyman, Sally A; McLaughlan, James R; Abou-Saleh, Radwa H; Marston, Gemma; Johnson, Benjamin R G; Freear, Steven; Coletta, P Louise; Markham, Alexander F; Evans, Stephen D

    2016-02-21

    Micron-sized lipid-stabilised bubbles of heavy gas have been utilised as contrast agents for diagnostic ultrasound (US) imaging for many years. Typically bubbles between 1 and 8 μm in diameter are produced to enhance imaging in US by scattering sound waves more efficiently than surrounding tissue. A potential area of interest for Contrast Enhanced Ultrasound (CEUS) are bubbles with diameters <1 μm or 'nanobubbles.' As bubble diameter decreases, ultrasonic resonant frequency increases, which could lead to an improvement in resolution for high-frequency imaging applications when using nanobubbles. In addition, current US contrast agents are limited by their size to the vasculature in vivo. However, molecular-targeted nanobubbles could penetrate into the extra-vascular space of cancerous tissue providing contrast in regions inaccessible to traditional microbubbles. This paper reports a new microfluidic method for the generation of sub-micron sized lipid stabilised particles containing perfluorocarbon (PFC). The nanoparticles are produced in a unique atomisation-like flow regime at high production rates, in excess of 10(6) particles per s and at high concentration, typically >10(11) particles per mL. The average particle diameter appears to be around 100-200 nm. These particles, suspected of being a mix of liquid and gaseous C4F10 due to Laplace pressure, then phase convert into nanometer sized bubbles on the application of US. In vitro ultrasound characterisation from these nanoparticle populations showed strong backscattering compared to aqueous filled liposomes of a similar size. The nanoparticles were stable upon injection and gave excellent contrast enhancement when used for in vivo imaging, compared to microbubbles with an equivalent shell composition. PMID:26689151

  2. The effect of different topical agents (silver sulfadiazine, povidone-iodine, and sodium chloride 0.9%) on burn injuries in rats.

    PubMed

    Yüksel, Emir Burak; Yıldırım, Alpagan Mustafa; Bal, Ali; Kuloglu, Tuncay

    2014-01-01

    It was aimed to comparatively evaluate the effects of dressing methods with silver sulfadiazine, povidone-iodine, and saline which have a common use in routine practices for burn injuries. Twenty-eight Sprague Dawley adult female rats were used in this study. All the rats were divided into 4 groups: the control group, the povidone-iodine group, the saline group, and the silver sulfadiazine group. On each rat, a second degree burn which covered less than 10% of the body surface area was created under general anesthesia by a metal comb including four probes with 2 × 1 cm area. The control group did not have any treatment during the experiment. Povidone-iodine, saline, and silver sulfadiazine administrations were performed under ether anesthesia every day. On 0, 7th, 14th, and 21st days of the study, tissue samples were taken for histological analyses. The sections taken from the paraffin blocks were stained and avidin-biotin-peroxidase method was used for collagen immune-reactivity. In the light microscope analyses, number of inflammatory cells, vascularization, fibroblast proliferation, collagen formation and epithelialization were evaluated histologically in all groups and analysed statistically. The agents that we used for injury healing in the treatment groups did not show any significant better results in comparison with the control group. In conclusion, further studies with the use of sodium chloride, silver sulfadiazine, and povidone-iodine by creating deeper and/or larger burn injury models are needed in order to accept these agents in routine treatment. PMID:25328700

  3. The Effect of Different Topical Agents (Silver Sulfadiazine, Povidone-Iodine, and Sodium Chloride 0.9%) on Burn Injuries in Rats

    PubMed Central

    Yüksel, Emir Burak; Yıldırım, Alpagan Mustafa; Kuloglu, Tuncay

    2014-01-01

    It was aimed to comparatively evaluate the effects of dressing methods with silver sulfadiazine, povidone-iodine, and saline which have a common use in routine practices for burn injuries. Twenty-eight Sprague Dawley adult female rats were used in this study. All the rats were divided into 4 groups: the control group, the povidone-iodine group, the saline group, and the silver sulfadiazine group. On each rat, a second degree burn which covered less than 10% of the body surface area was created under general anesthesia by a metal comb including four probes with 2 × 1 cm area. The control group did not have any treatment during the experiment. Povidone-iodine, saline, and silver sulfadiazine administrations were performed under ether anesthesia every day. On 0, 7th, 14th, and 21st days of the study, tissue samples were taken for histological analyses. The sections taken from the paraffin blocks were stained and avidin-biotin-peroxidase method was used for collagen immune-reactivity. In the light microscope analyses, number of inflammatory cells, vascularization, fibroblast proliferation, collagen formation and epithelialization were evaluated histologically in all groups and analysed statistically. The agents that we used for injury healing in the treatment groups did not show any significant better results in comparison with the control group. In conclusion, further studies with the use of sodium chloride, silver sulfadiazine, and povidone-iodine by creating deeper and/or larger burn injury models are needed in order to accept these agents in routine treatment. PMID:25328700

  4. Saline as the Sole Contrast Agent for Successful MRI-guided Epidural Injections

    SciTech Connect

    Deli, Martin; Mateiescu, Serban Busch, Martin; Becker, Jan Garmer, Marietta Groenemeyer, Dietrich

    2013-06-15

    Purpose. To assess the performance of sterile saline solution as the sole contrast agent for percutaneous magnetic resonance imaging (MRI)-guided epidural injections at 1.5 T. Methods. A retrospective analysis of two different techniques of MRI-guided epidural injections was performed with either gadolinium-enhanced saline solution or sterile saline solution for documentation of the epidural location of the needle tip. T1-weighted spoiled gradient echo (FLASH) images or T2-weighted single-shot turbo spin echo (HASTE) images visualized the test injectants. Methods were compared by technical success rate, image quality, table time, and rate of complications. Results. 105 MRI-guided epidural injections (12 of 105 with gadolinium-enhanced saline solution and 93 of 105 with sterile saline solution) were performed successfully and without complications. Visualization of sterile saline solution and gadolinium-enhanced saline solution was sufficient, good, or excellent in all 105 interventions. For either test injectant, quantitative image analysis demonstrated comparable high contrast-to-noise ratios of test injectants to adjacent body substances with reliable statistical significance levels (p < 0.001). The mean table time was 22 {+-} 9 min in the gadolinium-enhanced saline solution group and 22 {+-} 8 min in the saline solution group (p = 0.75). Conclusion. Sterile saline is suitable as the sole contrast agent for successful and safe percutaneous MRI-guided epidural drug delivery at 1.5 T.

  5. Ultrasound contrast agent fabricated from microbubbles containing instant adhesives, and its ultrasound imaging ability

    NASA Astrophysics Data System (ADS)

    Makuta, T.; Tamakawa, Y.

    2012-04-01

    Non-invasive surgery techniques and drug delivery system with acoustic characteristics of ultrasound contrast agent have been studied intensively in recent years. Ultrasound contrast agent collapses easily under the blood circulating and the ultrasound irradiating because it is just a stabilized bubble without solid-shell by surface adsorption of surfactant or lipid. For improving the imaging stability, we proposed the fabrication method of the hollow microcapsule with polymer shell, which can be fabricated just blowing vapor of commonly-used instant adhesive (Cyanoacrylate monomer) into water as microbubbles. Therefore, the cyanoacrylate vapor contained inside microbubble initiates polymerization on the gasliquid interface soon after microbubbles are generated in water. Consequently, hollow microspheres coated by cyanoacrylate thin film are generated. In this report, we revealed that diameter distributions of microbubbles and microcapsules were approximately same and most of them were less than 10 μm, that is, smaller than blood capillary. In addition, we also revealed that hollow microcapsules enhanced the acoustic signal especially in the harmonic contrast imaging and were broken or agglomerated under the ultrasound field. As for the yield of hollow microcapsules, we revealed that sodium dodecyl sulfate addition to water phase instead of deoxycolic acid made the fabrication yield increased.

  6. Optically tunable nanoparticle contrast agents for early cancer detection: model-based analysis of gold nanoshells.

    PubMed

    Lin, Alex W H; Lewinski, Nastassja A; West, Jennifer L; Halas, Naomi J; Drezek, Rebekah A

    2005-01-01

    Many optical diagnostic approaches rely on changes in scattering and absorption properties to generate optical contrast between normal and diseased tissue. Recently, there has been increasing interest in using exogenous agents to enhance this intrinsic contrast with particular emphasis on the development for targeting specific molecular features of disease. Gold nanoshells are a class of core-shell nanoparticles with an extremely tunable peak optical resonance ranging from the near-UV to the mid-IR wavelengths. Using current chemistries, nanoshells of a wide variety of core and shell sizes can easily be fabricated to scatter and/or absorb light with optical cross sections often several times larger than the geometric cross section. Using gold nanoshells of different size and optical parameters, we employ Monte Carlo models to predict the effect of varying concentrations of nanoshells on tissue reflectance. The models demonstrate the importance of absorption from the nanoshells on remitted signals even when the optical extinction is dominated by scattering. Furthermore, because of the strong optical response of nanoshells, a considerable change in reflectance is observed with only a very small concentration of nanoshells. Characterizing the optical behavior of gold nanoshells in tissue will aid in developing nanoshells as contrast agents for optical diagnostics. PMID:16409100

  7. XFM demonstrates preferential accumulation of a vanadyl-based MRI contrast agent in murine colonic tumors

    PubMed Central

    Mustafi, Devkumar; Ward, Jesse; Dougherty, Urszula; Bissonnette, Marc; Hart, John; Vogt, Stefan; Karczmar, Gregory S.

    2016-01-01

    Contrast agents that specifically enhance cancers on MRI would allow earlier detection. Vanadyl-based chelates (VCs) selectively enhance rodent cancers on MRI, suggesting selective uptake of VCs by cancers. Here we report X-ray fluorescence microscopy (XFM) of VC uptake by murine colon cancer. Colonic tumors in mice treated with azoxymethane/dextran sulfate sodium were identified by MRI. Then a gadolinium-based contrast agent and a VC were injected I.V.; mice were sacrificed and colons sectioned. VC distribution was sampled at 120 minutes after injection to evaluate the long term accumulation. Gadolinium distribution was sampled at 10 minutes after injection due to its rapid washout. XFM was performed on 72 regions of normal and cancerous colon from 5 normal mice and 4 cancer-bearing mice. XFM showed that all gadolinium was extracellular with similar concentrations in colon cancers and normal colon. In contrast, the average VC concentration was 2-fold higher in cancers vs. normal tissue (p<0.002). Cancers also contained numerous ‘hot spots’ with intracellular VC concentrations 6-fold higher than the concentration in normal colon (p<0.0001). No ‘hot spots’ were detected in normal colon. This is the first direct demonstration that VCs selectively accumulate in cancer cells, and thus may improve cancer detection. PMID:25813904

  8. Fluorescent Heterodoped Nanotetrapods as Synergistically Enhancing Positive and Negative Magnetic Resonance Imaging Contrast Agents.

    PubMed

    Sharma, V K; Alipour, A; Soran-Erdem, Z; Kelestemur, Y; Aykut, Z G; Demir, H V

    2016-05-18

    In this work, we report Mn-Fe heterodoped ZnSe tetrapod nanocrystals (NCs) synthesized to synergistically enhance contrast in both T1- and T2-weighted magnetic resonance imaging (MRI). The proposed NCs were prepared using a customized heteroarchitecture such that the manganese (Mn) is confined in the core and iron (Fe) in the branches of the tetrapods. The elemental composition and profile of these NCs were studied using X-ray photoelectron spectroscopy, energy-dispersive X-ray spectroscopy, and inductively coupled plasma mass spectroscopy. Photoluminescence quantum yield of these heterodoped NCs in water is ∼30%. Magnetic measurements reveal the simultaneous presence of superparamagnetic and paramagnetic behavior in these NCs because of the coexistence of Mn(2+) and Fe(2+) dopants. Their potential as simultaneous positive and negative MRI contrast agents was demonstrated by relaxivity measurements and in vivo MRI. From the in vivo studies, we also found that these NCs (with a hydrodynamic diameter of 20 nm) are excreted from the body within 24 h after the injection. Therefore, these heterodoped tetrapods NCs, while being fluorescent and safe, hold great future as a synergistically enhancing dual-modal MRI contrast agent. PMID:27139918

  9. Tracking contrast agents using real-time 2D photoacoustic imaging system for cardiac applications

    NASA Astrophysics Data System (ADS)

    Olafsson, Ragnar; Montilla, Leonardo; Ingram, Pier; Witte, Russell S.

    2009-02-01

    Photoacoustic (PA) imaging is a rapidly developing imaging modality that can detect optical contrast agents with high sensitivity. While detectors in PA imaging have traditionally been single element ultrasound transducers, use of array systems is desirable because they potentially provide high frame rates to capture dynamic events, such as injection and distribution of contrast in clinical applications. We present preliminary data consisting of 40 second sequences of coregistered pulse-echo (PE) and PA images acquired simultaneously in real time using a clinical ultrasonic machine. Using a 7 MHz linear array, the scanner allowed simultaneous acquisition of inphase-quadrature (IQ) data on 64 elements at a rate limited by the illumination source (Q-switched laser at 20 Hz) with spatial resolution determined to be 0.6 mm (axial) and 0.4 mm (lateral). PA images had a signal-to-noise ratio of approximately 35 dB without averaging. The sequences captured the injection and distribution of an infrared-absorbing contrast agent into a cadaver rat heart. From these data, a perfusion time constant of 0.23 s-1 was estimated. After further refinement, the system will be tested in live animals. Ultimately, an integrated system in the clinic could facilitate inexpensive molecular screening for coronary artery disease.

  10. Copper oxide nanoparticles as contrast agents for MRI and ultrasound dual-modality imaging

    NASA Astrophysics Data System (ADS)

    Perlman, Or; Weitz, Iris S.; Azhari, Haim

    2015-08-01

    Multimodal medical imaging is gaining increased popularity in the clinic. This stems from the fact that data acquired from different physical phenomena may provide complementary information resulting in a more comprehensive picture of the pathological state. In this context, nano-sized contrast agents may augment the potential sensitivity of each imaging modality and allow targeted visualization of physiological points of interest (e.g. tumours). In this study, 7 nm copper oxide nanoparticles (CuO NPs) were synthesized and characterized. Then, in vitro and phantom specimens containing CuO NPs ranging from 2.4 to 320 μg · mL-1 were scanned, using both 9.4 T MRI and through-transmission ultrasonic imaging. The results show that the CuO NPs induce shortening of the magnetic T1 relaxation time on the one hand, and increase the speed of sound and ultrasonic attenuation coefficient on the other. Moreover, these visible changes are NP concentration-dependent. The change in the physical properties resulted in a substantial increase in the contrast-to-noise ratio (3.4-6.8 in ultrasound and 1.2-19.3 in MRI). In conclusion, CuO NPs are excellent candidates for MRI-ultrasound dual imaging contrast agents. They offer radiation-free high spatial resolution scans by MRI, and cost-effective high temporal resolution scans by ultrasound.

  11. Mesoporous silica nanoparticles as a breast cancer targeting contrast agent for ultrasound imaging

    NASA Astrophysics Data System (ADS)

    Milgroom, Andrew Carson

    Current clinical use of ultrasound for breast cancer diagnostics is strictly limited to a role as a supplementary detection method to other modalities, such as mammography or MRI. A major reason for ultrasound’s role as a secondary method is its inability to discern between cancerous and non-cancerous bodies of similar density, like dense calcifications or benign fibroadenomas. Its detection capabilities are further diminished by the variable density of the surrounding breast tissue with the progression of age. Preliminary studies suggest that mesoporous silica nanoparticles (MSNs) are a good candidate as an in situ contrast agent for ultrasound. By tagging the silica particle surface with the cancer-targeting antibody trastuzumab (Herceptin), suspect regions of interest can be better identified in real time with standard ultrasound equipment. Once the silica-antibody conjugate is injected into the bloodstream and enters the cancerous growth’s vasculature, the antibody arm will bind to HER2, a cell surface receptor known to be dysfunctional or overexpressed in certain types of breast cancer. As more particles aggregate at the cell surface, backscatter of the ultrasonic waves increases as a result of the higher porous silica concentration. This translates to an increased contrast around the lesion boundary. Tumor detection through ultrasound contrast enhancement provides a tremendous advantage over current cancer diagnostics because is it significantly cheaper and can be monitored in real time. Characterization of MCM-41 type MSNs suggests that these particles have sufficient stability and particle size distribution to penetrate through fenestrated tumor vasculature and accumulate in HER2+ breast cancer cells through the enhanced permeation and retention (EPR) effect. A study of acoustic properties showed that particle concentration is linearly correlated to image contrast in clinical frequency-range ultrasound, although less pronounced than typical microbubble

  12. Iodine poisoning

    MedlinePlus

    Iodine is a naturally occurring chemical. Small amounts are needed for good health. However, large doses can ... Children are especially sensitive to the effects of iodine. NOTE: Iodine is found in certain foods. However, ...

  13. Intravenous ultrasound contrast agents versus other imaging methods in pediatric patients with neoplastic diseases – a comparison

    PubMed Central

    Kosiak, Wojciech; Batko, Tomasz; Adamkiewicz-Drożyńska, Elżbieta; Szarmach, Arkadiusz

    2013-01-01

    The lack of registration of ultrasound contrast agents for use in patients below the age of 18 is a significant limitation of their usage. Despite this, examinations with the use of contrast agents are conducted in numerous centers, mainly as part of the diagnostic process of vesicoureteral reflux. Examinations after an intravenous administration of contrast agents are conducted rarely. The reason for this is not only the lack of registration, but also the lack of studies on their safety profile in paediatric patients or no guidelines concerning the dosage. It seems that imaging with the use of such agents could help solve certain clinical problems when other diagnostic methods fail. The paper presents selected cases of pediatric patients treated in oncological departments, in whom the examination with the use of ultrasound contrast agents had a considerable influence on the diagnostic and therapeutic process. PMID:26675552

  14. Microwave breast tumor detection and size estimation using contrast-agent-loaded magnetotactic bacteria.

    PubMed

    Chen, Yifan; Kosmas, Panagiotis; Martel, Sylvain

    2013-01-01

    We propose a new approach to microwave breast tumor detection based on the use of bio-compatible flagellated magnetotactic bacteria (MTB). Previous work has shown that the directions and speeds of these bacterial microrobots adapted to operate in human microvasculature can be guided along preplanned paths deep inside the human body through external magnetic fields. Furthermore, a microwave contrast agent can be loaded onto MTB to alter the dielectric properties of tissues near the agent. Based on these two phenomena, we illustrate how multiple agglomerations of MTB released into human breast could be tracked simultaneously and monitored using differential microwave imaging (DMI) techniques. We also present novel strategies to detect and localize a breast cancerous mass as well as estimate its size through this new DMI-trackable bacterial propulsion and steering approach, and use an anatomically realistic breast model as a testbed to verify the feasibility of this breast cancer diagnostic technique. PMID:24110977

  15. Time-resolved spectroscopy and near infrared imaging enhanced by receptor-targeted contrast agents for prostate cancer detection

    NASA Astrophysics Data System (ADS)

    Pu, Y.; Wang, W. B.; Tang, G. C.; Achilefu, S.; Alfano, R. R.

    2011-03-01

    Time-resolved spectroscopy and near infrared imaging enhanced by receptor-targeted contrast agents for prostate cancer detection will be presented. Two contrast agents, Cybesin and Cytate, were investigated using time-resolved spectroscopy in aqueous solution and cancerous and normal prostate tissues. The time evolution of the fluorescent dipole in solution was studied using a system of first-order linear differential equations containing two main parameters: the decay rate of emission and the rate of one orthogonal emission component transferring to another. An analytical polarization model was developed and used to extract rotational times and fluorescence anisotropies of the contrast agents in prostate tissues. The differences of rotational times and polarization anisotropies were observed for Cybesin (Cytate) in cancerous and normal prostate tissue, which reflect preferred bond of contrast agents and cancerous tissue cells. The conjugation of Cybesin (Cytate) to prostate cancerous cells offers high contrast between normal and cancerous tissues.

  16. Investigating the stability of gadolinium based contrast agents towards UV radiation.

    PubMed

    Birka, Marvin; Roscher, Jörg; Holtkamp, Michael; Sperling, Michael; Karst, Uwe

    2016-03-15

    Since the 1980s, the broad application of gadolinium(Gd)-based contrast agents for magnetic resonance imaging (MRI) has led to significantly increased concentrations of Gd in the aqueous environment. Little is known about the stability of these highly polar xenobiotics under environmental conditions, in wastewater and in drinking water treatment. Therefore, the stability of frequently applied Gd-based MRI contrast agents towards UV radiation was investigated. The hyphenation of hydrophilic interaction liquid chromatography (HILIC) with inductively coupled plasma mass spectrometry (ICP-MS) and of HILIC with electrospray ionization mass spectrometry (ESI-MS) provided quantitative elemental information as well as structural information. The contrast agents Gd-DTPA, Gd-DOTA and Gd-BT-DO3A showed a high stability in irradiation experiments applying a wavelength range from 220 nm to 500 nm. Nevertheless, the degradation of Gd-BOPTA as well as the formation of Gd-containing transformation products was observed by means of HILIC-ICP-MS. Matrix-dependent irradiation experiments showed a degradation of Gd-BOPTA down to 3% of the initial amount in purified water after 300 min, whereas the degradation was slowed down in drinking water and surface water. Furthermore, it was observed that the sum of species continuously decreased with proceeding irradiation in all matrices. After irradiation in purified water for 300 min only 16% of the sum of species was left. This indicates a release of Gd(III) ions from the complex in course of irradiation. HILIC-ESI-MS measurements revealed that the transformation products mostly resulted from O-dealkylation and N-dealkylation reactions. In good correlation with retention times, the majority of transformation products were found to be more polar than Gd-BOPTA itself. Based on accurate masses, sum formulas were obtained and structures could be proposed. PMID:26802476

  17. Safety assessment of nanoparamagnetic contrast agents with different coatings for molecular MRI

    NASA Astrophysics Data System (ADS)

    Azizian, Gholamreza; Riyahi-Alam, Nader; Haghgoo, Soheila; Saffari, Mojtaba; Zohdiaghdam, Reza; Gorji, Ensieh

    2013-04-01

    Despite the wide application of gadolinium as a contrast agent for magnetic resonance imaging (MRI), there is a serious lack of information on its toxicity. Gadolinium and gadolinium oxide (Gd-oxide) are used as contrast agents for magnetic resonance imaging (MRI). There are methods for reducing toxicity of these materials, such as core nanoparticles coating or conjugating. Therefore, for toxicity evaluation, we compared the viability of commercial contrast agents in MRI (Gd-DTPA) and three nanoparticles with the same core Gd2O3 and small particulate gadolinium oxide or SPGO (< 40 nm) but different coatings of diethyleneglycol (DEG) as Gd2O3-DEG and methoxy polyethylene glycol-silane (mPEG-silane: 550 and 2000 Dalton) as SPGO-mPEG-silane550 and SPGO-mPEG-silane2000, respectively, in the SK-MEL3 cell line, by light microscopy, MTT assay using 3-[4,5-dimethylthiazol-2-yl]-2,5-diphenyl tetrazolium bromide, and the LDH assay detecting lactate dehydrogenase activity. The viability values were not statistically different between the three nanoparticles and Gd-DTPA. The MTT and LDH assay results showed that Gd2O3-DEG nanoparticles were more toxic than Gd-DTPA and other nanoparticles. Also, SPGO-mPEG-silane2000 was more biocompatible than other nanoparticles. The obtained results did not show any significant increase in cytotoxicity of the nanoparticles and Gd-DTPA, neither dose-dependent nor time-dependent. Therefore, DEG and PEG, due to their considerable properties and irregular sizes (different molecular weights), were selected as the useful surface covering materials of nanomagnetic particles that could reveal noticeable relaxivity and biocompatibility characteristics.

  18. Synthesis and characterization of a redox- and light-sensitive MRI contrast agent

    PubMed Central

    Tu, Chuqiao; Osborne, Elizabeth A.; Louie, Angelique Y.

    2009-01-01

    A redox- and light-sensitive, T1-weighted magnetic resonance imaging (MRI) contrast agent which tethers a spiropyran(SP)/merocyanine(MC) motif to a Gd-DO3A moiety was synthesized and characterized. When in the dark, the probe is in its MC form which has an r1 relaxivity of 2.51 mM−1s−1 (60MHz, 37°C). After irradiation with visible light or mixing with NADH, the probe experiences an isomerization and the r1 relaxivity decreased 18% and 26%, respectively. Additionally, the signal intensity in MRI showed an observable decrease after the compound was mixed with NADH. PMID:20126289

  19. Cleaved iron oxide nanoparticles as T2 contrast agents for magnetic resonance imaging.

    PubMed

    Jeon, Sung Lan; Chae, Min Kyung; Jang, Eun Ju; Lee, Chulhyun

    2013-03-25

    Iron oxide nanoparticles as contrast agents are reported to effectively improve magnetic resonance imaging of tissues and cells. In this work, cleaved iron oxide nanoparticles (CIONPs) were generated from hydrophobic FeO nanoparticles (HIONPs) by coating their surfaces with PEG-phospholipids, oxidizing them under water, and slowly removing the residual FeO phase in phthalate buffer. The synthesized CIONPs showed good r2 values of up to 258 s(-1)  mM(-1). Thus, the CIONPs can be employed as vectors for drug delivery due to their unique structure with an empty inner space, which enables their use in a wide range of applications. PMID:23345158

  20. Gold nanoclusters as contrast agents for fluorescent and X-ray dual-modality imaging.

    PubMed

    Zhang, Aili; Tu, Yu; Qin, Songbing; Li, Yan; Zhou, Juying; Chen, Na; Lu, Qiang; Zhang, Bingbo

    2012-04-15

    Multimodal imaging technique is an alternative approach to improve sensitivity of early cancer diagnosis. In this study, highly fluorescent and strong X-ray absorption coefficient gold nanoclusters (Au NCs) are synthesized as dual-modality imaging contrast agents (CAs) for fluorescent and X-ray dual-modality imaging. The experimental results show that the as-prepared Au NCs are well constructed with ultrasmall sizes, reliable fluorescent emission, high computed tomography (CT) value and fine biocompatibility. In vivo imaging results indicate that the obtained Au NCs are capable of fluorescent and X-ray enhanced imaging. PMID:22289255

  1. Site-targeted acoustic contrast agent detects molecular expression of tissue factor after balloon angioplasty

    NASA Astrophysics Data System (ADS)

    Hall, Christopher S.; Abendschein, Dana R.; Scherrer, David E.; Scott, Michael J.; Marsh, Jon N.; Wickline, Samuel A.; Lanza, Gregory M.

    2000-04-01

    Complex molecular signaling heralds the early stages of pathologies such as angiogenesis, inflammation, and cellular responses to mechanically damaged coronary arteries after balloon angioplasty. In previous studies, we have demonstrated acoustic enhancement of blood clot morphology with the use of a nongaseous, ligand-targeted acoustic nanoparticle emulsion delivered to areas of thrombosis both in vitro and in vivo. In this paper, we characterize the early expression of tissue factor which contributes to subsequent arterial restenosis. Tissue factor is a 42kd glycoprotein responsible for blood coagulation but also plays a well-described role in cancer metastasis, angiogenesis, and vascular restenosis. This study was designed to determine whether the targeted contrast agent could localize tissue factor expressed within the wall of balloon-injured arteries. Both carotid arteries of five pigs (20 kg) were injured using an 8 X 20 mm angioplasty balloon. The carotids were treated in situ with a perfluorocarbon nanoparticle emulsion covalently complexed to either specific anti-tissue factor polyclonal F(ab) fragments (treatment) or non-specific IgG F(ab) fragments (control). Intravascular ultrasound (30 MHz) images of the arteries were obtained before and after exposure to the emulsions. Tissue- factor targeted ultrasonic contrast agent acoustically enhanced the subintima and media at the site of balloon- induced injury compared with control contrast arteries (p less than 0.05). Immunohistochemical staining confirmed the presence of increased tissue factor at the sites of acoustic enhancement. Binding of the targeted agents was demonstrated in vitro by scanning electron microscope images of cultured smooth muscle cells that constitutively express tissue factor. This study demonstrates the concept of molecular imaging and localization of carotid arteries' tissue factor in vivo using a new, nanoparticulate emulsion. Enhancement of the visualization of the molecular

  2. Simple method for quantification of gadolinium magnetic resonance imaging contrast agents using ESR spectroscopy.

    PubMed

    Takeshita, Keizo; Kinoshita, Shota; Okazaki, Shoko

    2012-01-01

    To develop an estimation method of gadolinium magnetic resonance imaging (MRI) contrast agents, the effect of concentration of Gd compounds on the ESR spectrum of nitroxyl radical was examined. A solution of either 4-oxo-2,2,6,6-tetramethylpiperidine-N-oxyl (TEMPONE) or 4-hydroxy-2,2,6,6-tetramethylpiperidine-N-oxyl (TEMPOL) was mixed with a solution of Gd compound and the ESR spectrum was recorded. Increased concentration of gadolinium-diethylenetriamine pentaacetic acid chelate (Gd-DTPA), an MRI contrast agent, increased the peak-to-peak line widths of ESR spectra of the nitroxyl radicals, in accordance with a decrease of their signal heights. A linear relationship was observed between concentration of Gd-DTPA and line width of ESR signal, up to approximately 50 mmol/L Gd-DTPA, with a high correlation coefficient. Response of TEMPONE was 1.4-times higher than that of TEMPOL as evaluated from the slopes of the lines. The response was slightly different among Gd compounds; the slopes of calibration curves for acua[N,N-bis[2-[(carboxymethyl)[(methylcarbamoyl)methyl]amino]ethyl]glycinato(3-)]gadolinium hydrate (Gd-DTPA-BMA) (6.22 μT·L/mmol) and gadolinium-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid chelate (Gd-DOTA) (6.62 μT·L/mmol) were steeper than the slope for Gd-DTPA (5.45 μT·L/mmol), whereas the slope for gadolinium chloride (4.94 μT·L/mmol) was less steep than that for Gd-DTPA. This method is simple to apply. The results indicate that this method is useful for rough estimation of the concentration of Gd contrast agents if calibration is carried out with each standard compound. It was also found that the plot of the reciprocal square root of signal height against concentrations of contrast agents could be useful for the estimation if a constant volume of sample solution is taken and measured at the same position in the ESR cavity every time. PMID:22223372

  3. Contrast agent free detection of bowel perforation using chlorophyll derivatives from food plants

    NASA Astrophysics Data System (ADS)

    Han, Jung Hyun; Jo, Young Goun; Kim, Jung Chul; Lee, Jee-Bum; Kim, Yong-Chul; Kang, Hoonsoo; Hwang, In-Wook

    2016-01-01

    Chlorophylls occur abundantly in food plants and show bright emission bands at long-wavelength regions (∼675 and ∼720 nm) compared to the autofluorescence of animal organs and peritoneal fluids. The use of these emissions as biomarkers for monitoring bowel perforation with a modality that does not involve synthetic contrast agents seems promising. To validate this, we measured the fluorescence spectra of rat organs, human peritoneal and intestinal fluids, and human intestinal fluids diluted with physiological saline. The developed technique showed a high detection sensitivity (∼50 ppm) under irrigation for abdominal surgery, highlighting the potential of this tool in the surgical setting.

  4. Development and optimization of near-IR contrast agents for immune cell tracking

    PubMed Central

    Joshi, Pratixa P.; Yoon, Soon Joon; Chen, Yun-Sheng; Emelianov, Stanislav; Sokolov, Konstantin V.

    2013-01-01

    Gold nanorods (NRs) are attractive for in vivo imaging due to their high optical cross-sections and tunable absorbance. However, the feasibility of using NRs for cell tracking has not been fully explored. Here, we synthesized dye doped silica-coated NRs as multimodal contrast agents for imaging of macrophages – immune cells which play an important role in cancer and cardiovascular diseases. We showed the importance of silica coating in imaging of NR-labeled cells. Photoacoustic (PA) imaging of NRs labeled macrophages showed high sensitivity. Therefore, these results provide foundation for applications of silica-coated NRs and PA imaging in tracking of immune cells. PMID:24298419

  5. Porous silicon nanoparticles as biocompatible contrast agents for magnetic resonance imaging

    SciTech Connect

    Gongalsky, M. B. Kargina, Yu. V.; Osminkina, L. A.; Perepukhov, A. M.; Maximychev, A. V.; Gulyaev, M. V.; Vasiliev, A. N.; Pirogov, Yu. A.; Timoshenko, V. Yu.

    2015-12-07

    We propose porous silicon nanoparticles (PSi NPs) with natural oxide coating as biocompatible and bioresorbable contrast agents for magnetic resonant imaging (MRI). A strong shortening of the transversal proton relaxation time (T{sub 2}) was observed for aqueous suspensions of PSi NPs, whereas the longitudinal relaxation time (T{sub 1}) changed moderately. The longitudinal and transversal relaxivities are estimated to be 0.03 and 0.4 l/(g·s), respectively, which are promising for biomedical studies. The proton relaxation is suggested to undergo via the magnetic dipole-dipole interaction with Si dangling bonds on surfaces of PSi NPs. MRI experiments with phantoms have revealed the remarkable contrasting properties of PSi NPs for medical diagnostics.

  6. Contrast Agent Ultrasonography before and after HIFU Treatment of Parathyroid Glands

    NASA Astrophysics Data System (ADS)

    Kovatcheva, Roussanka; Arnaud, Françoise; Lacoste, François

    2010-03-01

    OBJECTIVES: To observe changes in the parathyroid tissue treated by extracorporeal HIFU. MATERIAL AND METHODS: 5 patients were treated for primary hyperparathyroidism by thermally ablating enlarged parathyroid glands using an external HIFU applicator. The treated glands were visualized with B-Mode and contrast enhanced ultrasonography (CEUS) before, 1 week and 4 weeks post HIFU. Serum iPTH, calcium, and phosphorus levels were monitored before and after the treatment. RESULTS: The initial results showed a correlation between contrast agent uptake of treated parathyroid tissue, the reduction of volume of the gland and the decrease of iPTH levels. CONCLUSIONS These results show it is possible to use CEUS to monitor the thermal ablation of parathyroid glands.

  7. Object reconstruction in scattering medium using multiple elliptical polarized speckle contrast projections and optical clearing agents

    NASA Astrophysics Data System (ADS)

    Moshe, Tomer; Firer, Michael A.; Abookasis, David

    2015-05-01

    In this paper, we present a hybrid method for improving the imaging quality of objects obscured within a scattering environment by combining multiple elliptical polarized speckle contrast projections with the use of optical clearing agents (OCAs). Elliptically polarized light enables the probing of subsurface volumes, where OCAs decrease light scattering while increasing photons' penetration depth through the medium. Experiments were conducted on object sample and prostate cancer cells embedded within ex vivo biological samples (chicken breasts) in reflection configuration. After immersion with OCAs, the medium was irradiated with an elliptically polarized laser beam and multiple polarized speckled images obtained from a lens array were first converted to speckled contrast images and then processed using a self-deconvolution shift-and-add algorithm. The conversion to contrast images and multiple perspectives acquisition was found to emphasize contrast. Analysis of image quality indicated improvement in object visualization by the combination of elliptical polarization and OCAs. This enhanced imaging strategy may advance the development of improved methods in biomedicine field, specifically biomedical tomography.

  8. Development and evaluation of a novel VEGFR2-targeted nanoscale ultrasound contrast agents

    NASA Astrophysics Data System (ADS)

    Yu, Houqiang; Li, Chunfang; He, Xiaoling; Zhou, Qibing; Ding, Mingyue

    2016-04-01

    Recent literatures have reported that the targeted nanoscale ultrasound contrast agents are becoming more and more important in medical application, like ultrasound imaging, detection of perfusion, drug delivery and molecular imaging and so on. In this study, we fabricated an uniform nanoscale bubbles (257 nm with the polydispersity index of 0.458) by incorporation of antibody targeted to vascular endothelial growth factor receptor 2 (VEGFR2) into the nanobubbles membrane by using avidin-biotin interaction. Some fundamental characterizations such as nanobubble suspension, surface morphology, particle size distribution and zeta potential were investigated. The concentration and time-intensity curves (TICs) were obtained with a self-made ultrasound experimental setup in vitro evaluation. In addition, in order to evaluate the contrast enhancement ability and the potential tumor-targeted ability in vivo, normal Wistar rats and nude female BALB/c mice were intravascular administration of the nanobubbles via tail vein injection, respectively. Significant contrast enhancement of ultrasound imaging within liver and tumor were visualized. These experiments demonstrated that the targeted nanobubbles is efficient in ultrasound molecular imaging by enhancement of the contrast effect and have potential capacity for targeted tumor diagnosis and therapy in the future.

  9. Parallel Comparative Studies on Mouse Toxicity of Oxide Nanoparticle- and Gadolinium-Based T1 MRI Contrast Agents.

    PubMed

    Chen, Rui; Ling, Daishun; Zhao, Lin; Wang, Shuaifei; Liu, Ying; Bai, Ru; Baik, Seungmin; Zhao, Yuliang; Chen, Chunying; Hyeon, Taeghwan

    2015-12-22

    Magnetic resonance imaging (MRI) contrast agents with high relaxivity are highly desirable because they can significantly increase the accuracy of diagnosis. However, they can be potentially toxic to the patients. In this study, using a mouse model, we investigate the toxic effects and subsequent tissue damage induced by three T1 MRI contrast agents: gadopentetate dimeglumine injection (GDI), a clinically used gadolinium (Gd)-based contrast agent (GBCAs), and oxide nanoparticle (NP)-based contrast agents, extremely small-sized iron oxide NPs (ESIONs) and manganese oxide (MnO) NPs. Biodistribution, hematological and histopathological changes, inflammation, and the endoplasmic reticulum (ER) stress responses are evaluated for 24 h after intravenous injection. These thorough assessments of the toxic and stress responses of these agents provide a panoramic description of safety concerns and underlying mechanisms of the toxicity of contrast agents in the body. We demonstrate that ESIONs exhibit fewer adverse effects than the MnO NPs and the clinically used GDI GBCAs, providing useful information on future applications of ESIONs as potentially safe MRI contrast agents. PMID:26567968

  10. X-ray scatter imaging of hepatocellular carcinoma in a mouse model using nanoparticle contrast agents

    DOE PAGESBeta

    Rand, Danielle; Derdak, Zoltan; Carlson, Rolf; Wands, Jack R.; Rose-Petruck, Christoph

    2015-10-29

    Hepatocellular carcinoma (HCC) is one of the most common malignant tumors worldwide and is almost uniformly fatal. Current methods of detection include ultrasound examination and imaging by CT scan or MRI; however, these techniques are problematic in terms of sensitivity and specificity, and the detection of early tumors (<1 cm diameter) has proven elusive. Better, more specific, and more sensitive detection methods are therefore urgently needed. Here we discuss the application of a newly developed x-ray imaging technique called Spatial Frequency Heterodyne Imaging (SFHI) for the early detection of HCC. SFHI uses x-rays scattered by an object to form anmore » image and is more sensitive than conventional absorption-based x-radiography. We show that tissues labeled in vivo with gold nanoparticle contrast agents can be detected using SFHI. We also demonstrate that directed targeting and SFHI of HCC tumors in a mouse model is possible through the use of HCC-specific antibodies. As a result, the enhanced sensitivity of SFHI relative to currently available techniques enables the x-ray imaging of tumors that are just a few millimeters in diameter and substantially reduces the amount of nanoparticle contrast agent required for intravenous injection relative to absorption-based x-ray imaging.« less

  11. X-ray scatter imaging of hepatocellular carcinoma in a mouse model using nanoparticle contrast agents

    SciTech Connect

    Rand, Danielle; Derdak, Zoltan; Carlson, Rolf; Wands, Jack R.; Rose-Petruck, Christoph

    2015-10-29

    Hepatocellular carcinoma (HCC) is one of the most common malignant tumors worldwide and is almost uniformly fatal. Current methods of detection include ultrasound examination and imaging by CT scan or MRI; however, these techniques are problematic in terms of sensitivity and specificity, and the detection of early tumors (<1 cm diameter) has proven elusive. Better, more specific, and more sensitive detection methods are therefore urgently needed. Here we discuss the application of a newly developed x-ray imaging technique called Spatial Frequency Heterodyne Imaging (SFHI) for the early detection of HCC. SFHI uses x-rays scattered by an object to form an image and is more sensitive than conventional absorption-based x-radiography. We show that tissues labeled in vivo with gold nanoparticle contrast agents can be detected using SFHI. We also demonstrate that directed targeting and SFHI of HCC tumors in a mouse model is possible through the use of HCC-specific antibodies. As a result, the enhanced sensitivity of SFHI relative to currently available techniques enables the x-ray imaging of tumors that are just a few millimeters in diameter and substantially reduces the amount of nanoparticle contrast agent required for intravenous injection relative to absorption-based x-ray imaging.

  12. Virus-mimicking nano-constructs as a contrast agent for near infrared photoacoustic imaging

    NASA Astrophysics Data System (ADS)

    Gupta, Sharad; Chatni, Muhammad R.; Rao, Ayala L. N.; Vullev, Valentine I.; Wang, Lihong V.; Anvari, Bahman

    2013-02-01

    We report the first proof-of-principle demonstration of photoacoustic imaging using a contrast agent composed of a plant virus protein shell, which encapsulates indocyanine green (ICG), the only FDA-approved near infrared chromophore. These nano-constructs can provide higher photoacoustic signals than blood in tissue phantoms, and display superior photostability compared to non-encapsulated ICG. Our preliminary results suggest that the constructs do not elicit an acute immunogenic response in healthy mice.We report the first proof-of-principle demonstration of photoacoustic imaging using a contrast agent composed of a plant virus protein shell, which encapsulates indocyanine green (ICG), the only FDA-approved near infrared chromophore. These nano-constructs can provide higher photoacoustic signals than blood in tissue phantoms, and display superior photostability compared to non-encapsulated ICG. Our preliminary results suggest that the constructs do not elicit an acute immunogenic response in healthy mice. Electronic supplemental information (ESI) available: Information on experimental procedure for fabrication of the nano-constructs, photoacoustic imaging, and immunogenic studies. See DOI: 10.1039/c3nr34124k

  13. High Relaxivity Gadolinium Hydroxypyridonate-Viral Capsid Conjugates: Nano-sized MRI Contrast Agents

    SciTech Connect

    Meux, Susan C.; Datta, Ankona; Hooker, Jacob M.; Botta, Mauro; Francis, Matthew B.; Aime, Silvio; Raymond, Kenneth N.

    2007-08-29

    High relaxivity macromolecular contrast agents based on the conjugation of gadolinium chelates to the interior and exterior surfaces of MS2 viral capsids are assessed. The proton nuclear magnetic relaxation dispersion (NMRD) profiles of the conjugates show up to a five-fold increase in relaxivity, leading to a peak relaxivity (per Gd{sup 3+} ion) of 41.6 mM{sup -1}s{sup -1} at 30 MHz for the internally modified capsids. Modification of the exterior was achieved through conjugation to flexible lysines, while internal modification was accomplished by conjugation to relatively rigid tyrosines. Higher relaxivities were obtained for the internally modified capsids, showing that (1) there is facile diffusion of water to the interior of capsids and (2) the rigidity of the linker attaching the complex to the macromolecule is important for obtaining high relaxivity enhancements. The viral capsid conjugated gadolinium hydroxypyridonate complexes appear to possess two inner-sphere water molecules (q = 2) and the NMRD fittings highlight the differences in the local motion for the internal ({tau}{sub RI} = 440 ps) and external ({tau}{sub RI} = 310 ps) conjugates. These results indicate that there are significant advantages of using the internal surface of the capsids for contrast agent attachment, leaving the exterior surface available for the installation of tissue targeting groups.

  14. BR1: A new ultrasonographic contrast agent based on sulfur hexafluoride-filled microbubbles

    SciTech Connect

    Scheider, M.; Arditi, M.; Barrau, M.B.

    1995-08-01

    Rationale and objectives. The basic characteristics of BR1, a novel echo contrast agent based on stabilized sulfur hexafluoride (SF{sub 6}) microbubbles have been evaluated. Methods. The authors determined the physicochemical properties (bubble concentration, bubble size distribution, resistance to pressure, and stability) and the acoustic properties (backscatter and attenuation coefficients) of BR1. The diagnostic value of BR1 was evaluated further in minipigs. Left heart images were recorded before and after injection of different doses of BR1. Results. BR1 is formulated as a lyophilized products, which after addition of saline, provides a suspension containing 2 X 10{sup 8} SF{sub 6} microbubbles/mL with a number mean diameter of 2.5 {mu}m. More than 90% of the bubbles are below 8 {mu}m. The use of SF{sub 6} rather than air provides an improved resistance to pressure increases such as the ones occuring in the left heart during systole. After reconstitution, the echogenicity and the bubble characteristics are unchanged for more than 8 hours. The high echogenicity remains almost constant over the entire medical frequency range (1-10 MH{sub Z}). BR1 injections in animals resulted in a homogenous, dose-dependent opacification of the left heart. Conclusions. Considering its high echogenicity, outstanding stability, and resistance to pressure changes, BR1 is a very promising ultrasound contrast agent. 14 refs., 8 figs., 3 tabs.

  15. X-ray Scatter Imaging of Hepatocellular Carcinoma in a Mouse Model Using Nanoparticle Contrast Agents

    PubMed Central

    Rand, Danielle; Derdak, Zoltan; Carlson, Rolf; Wands, Jack R.; Rose-Petruck, Christoph

    2015-01-01

    Hepatocellular carcinoma (HCC) is one of the most common malignant tumors worldwide and is almost uniformly fatal. Current methods of detection include ultrasound examination and imaging by CT scan or MRI; however, these techniques are problematic in terms of sensitivity and specificity, and the detection of early tumors (<1 cm diameter) has proven elusive. Better, more specific, and more sensitive detection methods are therefore urgently needed. Here we discuss the application of a newly developed x-ray imaging technique called Spatial Frequency Heterodyne Imaging (SFHI) for the early detection of HCC. SFHI uses x-rays scattered by an object to form an image and is more sensitive than conventional absorption-based x-radiography. We show that tissues labeled in vivo with gold nanoparticle contrast agents can be detected using SFHI. We also demonstrate that directed targeting and SFHI of HCC tumors in a mouse model is possible through the use of HCC-specific antibodies. The enhanced sensitivity of SFHI relative to currently available techniques enables the x-ray imaging of tumors that are just a few millimeters in diameter and substantially reduces the amount of nanoparticle contrast agent required for intravenous injection relative to absorption-based x-ray imaging. PMID:26511147

  16. Mechanical stability of hollow spherical nano-aggregates as ultrasound contrast agent.

    PubMed

    Hadinoto, Kunn

    2009-06-01

    Gas-filled hollow nanoparticulate aggregates designed for use as an ultrasound contrast agent and as an ultrasound-mediated nanoparticulate drug delivery vehicle are manufactured by spray drying of nanoparticulate suspension at a fast convective drying rate. The gas outward diffusion from the hollow particles during insonication reduces the shell mechanical stability hence shortening the lifespan of the ultrasound contrast agent. The present work aims to develop a formulation method to produce micron-size hollow nanoparticulate aggregates with high shell mechanical stability by controlling the shell thickness-to-particle radius (S/R) ratio. The impacts of changing (1) the spray drying parameters, (2) nanoparticulate suspension concentration, and (3) surfactant inclusion (i.e. phospholipids) on the particle morphology and the S/R ratio are investigated. Biocompatible PMMA-MeOPEGMA nanoparticles of varying sizes (i.e. 50+/-20, 110+/-40, and 230+/-80 nm) are used as the model nanoparticles. The results indicate that the S/R ratio increases with decreasing particle size and the shell mechanical stability is linearly dependent on the S/R ratio. The effects of the spray drying parameters and nanoparticle concentration are found to be minimal in the absence of the phospholipids. The S/R ratio can be significantly increased by using larger size nanoparticles with the phospholipids inclusion. PMID:19446772

  17. X-ray Scatter Imaging of Hepatocellular Carcinoma in a Mouse Model Using Nanoparticle Contrast Agents

    NASA Astrophysics Data System (ADS)

    Rand, Danielle; Derdak, Zoltan; Carlson, Rolf; Wands, Jack R.; Rose-Petruck, Christoph

    2015-10-01

    Hepatocellular carcinoma (HCC) is one of the most common malignant tumors worldwide and is almost uniformly fatal. Current methods of detection include ultrasound examination and imaging by CT scan or MRI; however, these techniques are problematic in terms of sensitivity and specificity, and the detection of early tumors (<1 cm diameter) has proven elusive. Better, more specific, and more sensitive detection methods are therefore urgently needed. Here we discuss the application of a newly developed x-ray imaging technique called Spatial Frequency Heterodyne Imaging (SFHI) for the early detection of HCC. SFHI uses x-rays scattered by an object to form an image and is more sensitive than conventional absorption-based x-radiography. We show that tissues labeled in vivo with gold nanoparticle contrast agents can be detected using SFHI. We also demonstrate that directed targeting and SFHI of HCC tumors in a mouse model is possible through the use of HCC-specific antibodies. The enhanced sensitivity of SFHI relative to currently available techniques enables the x-ray imaging of tumors that are just a few millimeters in diameter and substantially reduces the amount of nanoparticle contrast agent required for intravenous injection relative to absorption-based x-ray imaging.

  18. Targeted nanodiamonds as phenotype-specific photoacoustic contrast agents for breast cancer.

    PubMed

    Zhang, Ti; Cui, Huizhong; Fang, Chia-Yi; Cheng, Kun; Yang, Xinmai; Chang, Huan-Cheng; Forrest, M Laird

    2015-03-01

    The aim is to develop irradiated nanodiamonds (INDs) as a molecularly targeted contrast agent for high-resolution and phenotype-specific detection of breast cancer with photoacoustic (PA) imaging. The surface of acid treated radiation-damaged nanodiamonds was grafted with PEG to improve its stability and circulation time in blood, followed by conjugation to an anti-HER2 peptide with a final nanoparticle size of approximately 92 nm. Immunocompetent mice bearing orthotopic HER2-positive or negative tumors were administered INDs and PA imaged using an 820-nm near-infrared laser. PA images demonstrated that INDs accumulate in tumors and completely delineated the entire tumor within 10 h. HER2 targeting significantly enhanced imaging of HER2-positive tumors. Pathological examination demonstrated INDs are nontoxic. PA technology is adaptable to low-cost bedside medicine, and with new contrast agents described herein, PA can achieve high-resolution (sub-mm) and phenotype-specific monitoring of cancer growth. PMID:25723091

  19. Carboxylated magnetic nanoparticles as MRI contrast agents: Relaxation measurements at different field strengths

    NASA Astrophysics Data System (ADS)

    Jedlovszky-Hajdú, Angéla; Tombácz, Etelka; Bányai, István; Babos, Magor; Palkó, András

    2012-09-01

    At the moment the biomedical applications of magnetic fluids are the subject of intensive scientific interest. In the present work, magnetite nanoparticles (MNPs) were synthesized and stabilized in aqueous medium with different carboxylic compounds (citric acid (CA), polyacrylic acid (PAA), and sodium oleate (NaOA)), in order to prepare well stabilized magnetic fluids (MFs). The magnetic nanoparticles can be used in the magnetic resonance imaging (MRI) as contrast agents. Magnetic resonance relaxation measurements of the above MFs were performed at different field strengths (i.e., 0.47, 1.5 and 9.4 T) to reveal the field strength dependence of their magnetic responses, and to compare them with that of ferucarbotran, a well-known superparamagnetic contrast agent. The measurements showed characteristic differences between the tested magnetic fluids stabilized by carboxylic compounds and ferucarbotran. It is worthy of note that our magnetic fluids have the highest r2 relaxivities at the field strength of 1.5 T, where the most of the MRI works in worldwide.

  20. Evolution of contrast agents for ultrasound imaging and ultrasound-mediated drug delivery

    PubMed Central

    Paefgen, Vera; Doleschel, Dennis; Kiessling, Fabian

    2015-01-01

    Ultrasound (US) is one of the most frequently used diagnostic methods. It is a non-invasive, comparably inexpensive imaging method with a broad spectrum of applications, which can be increased even more by using bubbles as contrast agents (CAs). There are various different types of bubbles: filled with different gases, composed of soft- or hard-shell materials, and ranging in size from nano- to micrometers. These intravascular CAs enable functional analyses, e.g., to acquire organ perfusion in real-time. Molecular analyses are achieved by coupling specific ligands to the bubbles’ shell, which bind to marker molecules in the area of interest. Bubbles can also be loaded with or attached to drugs, peptides or genes and can be destroyed by US pulses to locally release the entrapped agent. Recent studies show that US CAs are also valuable tools in hyperthermia-induced ablation therapy of tumors, or can increase cellular uptake of locally released drugs by enhancing membrane permeability. This review summarizes important steps in the development of US CAs and introduces the current clinical applications of contrast-enhanced US. Additionally, an overview of the recent developments in US probe design for functional and molecular diagnosis as well as for drug delivery is given. PMID:26441654

  1. Small animal optoacoustic tomography system for molecular imaging of contrast agents

    NASA Astrophysics Data System (ADS)

    Su, Richard; Liopo, Anton; Ermilov, Sergey A.; Oraevsky, Alexander A.

    2016-03-01

    We developed a new and improved Laser Optoacoustic Imaging System, LOIS-3D for preclinical research applications in small animal models. The advancements include (i) a new stabilized imaging module with a more homogeneous illumination of the mouse yielding a better spatial resolution (<0.2 mm) and (ii) a new low noise amplifier incorporated into the ultrasonic probe and providing the noise equivalent pressure around 2 Pa resulting in increased signal-to-noise ratio and the optical absorption sensitivity of about 0.15 cm-1. We also improved scan time and the image reconstruction times. This prototype has been commercialized for a number of biomedical research applications, such as imaging vascularization and measuring hemoglobin / oxyhemoglobin distribution in the organs as well as imaging exogenous or endogenous optoacoustic contrast agents. As examples, we present in vivo experiments using phantoms and mice with and without tumor injected with contrast agents with indocyanine green (ICG). LOIS-3D was capable of detecting ~1-2 pmole of the ICG, in tissues with relatively low blood content. With its high sensitivity and excellent spatial resolution LOIS-3D is an advanced alternative to fluorescence and bioluminescence based modalities for molecular imaging in live mice.

  2. The performance of PEGylated nanocapsules of perfluorooctyl bromide as an ultrasound contrast agent.

    PubMed

    Díaz-López, Raquel; Tsapis, Nicolas; Santin, Mathieu; Bridal, Sharon Lori; Nicolas, Valérie; Jaillard, Danielle; Libong, Danielle; Chaminade, Pierre; Marsaud, Véronique; Vauthier, Christine; Fattal, Elias

    2010-03-01

    The surface of polymeric nanocapsules used as ultrasound contrast agents (UCAs) was modified with PEGylated phospholipids in order to escape recognition and clearance by the mononuclear phagocyte system and achieve passive tumor targeting. Nanocapsules consisted of a shell of poly(lactide-co-glycolide) (PLGA) encapsulating a liquid core of perfluorooctyl bromide (PFOB). They were decorated with poly(ethylene glycol-2000)-grafted distearoylphosphatidylethanolamine (DSPE-PEG) incorporated in the organic phase before the solvent emulsification-evaporation process. The influence of DSPE-PEG concentration on nanocapsule size, surface charge, morphology, hydrophobicity and complement activation was evaluated. Zeta potential measurements, Hydrophobic interaction chromatography and complement activation provide evidence of DSPE-PEG presence at nanocapsule surface. Electronic microscopy reveals that the core/shell structure is preserved up to 2.64 mg of DSPE-PEG for 100 mg PLGA. In vivo ultrasound imaging was performed in mice bearing xenograft tumor with MIA PaCa-2 cells, either after an intra-tumoral or intravenous injection of nanocapsules. Tumor was observed only after the intra-tumoral injection. Despite the absence of echogenic signal in the tumor after intravenous injection of nanocapsules, histological analysis reveals their accumulation within the tumor tissue demonstrating that tissue distribution is not the unique property required for ultrasound contrast agents to be efficient. PMID:19948357

  3. GRPR-targeted Protein Contrast Agents for Molecular Imaging of Receptor Expression in Cancers by MRI

    PubMed Central

    Pu, Fan; Qiao, Jingjuan; Xue, Shenghui; Yang, Hua; Patel, Anvi; Wei, Lixia; Hekmatyar, Khan; Salarian, Mani; Grossniklaus, Hans E.; Liu, Zhi-Ren; Yang, Jenny J.

    2015-01-01

    Gastrin-releasing peptide receptor (GRPR) is differentially expressed on the surfaces of various diseased cells, including prostate and lung cancer. However, monitoring temporal and spatial expression of GRPR in vivo by clinical MRI is severely hampered by the lack of contrast agents with high relaxivity, targeting capability and tumor penetration. Here, we report the development of a GRPR-targeted MRI contrast agent by grafting the GRPR targeting moiety into a scaffold protein with a designed Gd3+ binding site (ProCA1.GRPR). In addition to its strong binding affinity for GRPR (Kd = 2.7 nM), ProCA1.GRPR has high relaxivity (r1 = 42.0 mM−1s−1 at 1.5 T and 25 °C) and strong Gd3+ selectivity over physiological metal ions. ProCA1.GRPR enables in vivo detection of GRPR expression and spatial distribution in both PC3 and H441 tumors in mice using MRI. ProCA1.GRPR is expected to have important preclinical and clinical implications for the early detection of cancer and for monitoring treatment effects. PMID:26577829

  4. Noninvasive MRI of β-cell function using a Zn2+-responsive contrast agent.

    PubMed

    Lubag, Angelo J M; De Leon-Rodriguez, Luis M; Burgess, Shawn C; Sherry, A Dean

    2011-11-01

    Elevation of postprandial glucose stimulates release of insulin from granules stored in pancreatic islet β-cells. We demonstrate here that divalent zinc ions coreleased with insulin from β-cells in response to high glucose are readily detected by MRI using the Zn(2+)-responsive T(1) agent, GdDOTA-diBPEN. Image contrast was significantly enhanced in the mouse pancreas after injection of a bolus of glucose followed by a low dose of the Zn(2+) sensor. Images of the pancreas were not enhanced by the agent in mice without addition of glucose to stimulate insulin release, nor were images enhanced in streptozotocin-treated mice with or without added glucose. These observations are consistent with MRI detection of Zn(2+) released from β-cells only during glucose-stimulated insulin secretion. Images of mice fed a high-fat (60%) diet over a 12-wk period and subjected to this same imaging protocol showed a larger volume of contrast-enhanced pancreatic tissue, consistent with the expansion of pancreatic β-cell mass during fat accumulation and progression to type 2 diabetes. This MRI sensor offers the exciting potential for deep-tissue monitoring of β-cell function in vivo during development of type 2 diabetes or after implantation of islets in type I diabetic patients. PMID:22025712

  5. Targeted Nanodiamonds as Phenotype Specific Photoacoustic Contrast Agents for Breast Cancer

    PubMed Central

    Zhang, Ti; Cui, Huizhong; Fang, Chia-Yi; Cheng, Kun; Yang, Xinmai; Chang, Huan-Cheng; Forrest, M. Laird

    2015-01-01

    Aim The aim is to develop irradiated nanodiamonds (INDs) as a molecularly-targeted contrast agent for high resolution and phenotype-specific detection of breast cancer with photoacoustic (PA) imaging. Materials & Methods The surface of acid treated radiation-damaged nanodiamonds was grafted with polyethylene glycol (PEG) to improve its stability and circulation time in blood, followed by conjugation to an anti-Human epidermal growth factor receptor-2 (HER2) peptide (KCCYSL) with a final nanoparticle size of ca. 92 nm. Immunocompetent mice bearing orthotopic HER2 positive or negative tumors were administered INDs and PA imaged using an 820-nm near infrared laser. Results PA images demonstrated that INDs accumulate in tumors and completely delineated the entire tumor within 10 hours. HER2 targeting significantly enhanced imaging of HER2-positive tumors. Pathological examination demonstrated INDs are non-toxic. Conclusions PA technology is adaptable to low-cost bedside medicine, and with new contrast agents described herein, PA can achieve high resolution (sub-mm) and phenotype specific monitoring of cancer growth. PMID:25723091

  6. Improved pH measurements with a single PARACEST MRI contrast agent

    PubMed Central

    Sheth, Vipul R.; Liu, Guanshu; Li, Yuguo; Pagel, Mark D.

    2016-01-01

    The measurement of extracellular pH has potential utility for assessing the therapeutic effects of pH-dependent and pH-altering therapies. A PARAmagnetic chemical exchange saturation transfer (PARACEST) MRI contrast agent, Yb–DO3A–oAA, has two CEST effects that are dependent on pH. A ratio derived from these CEST effects was linearly correlated with pH throughout the physiological pH range. The pH can be measured with a precision of 0.21 pH units and an accuracy of 0.09 pH units. The pH measurement is independent of concentration and T1 relaxation times, but is dependent on temperature. Although MR coalescence affects the CEST measurements, especially at high pH, the ratiometric analysis of the CEST effects can account for incomplete saturation of the agent’s amide and amine that results from MR coalescence. Provided that an empirical calibration is determined with saturation conditions, magnetic field strength and temperature that can be used for subsequent studies, these results demonstrate that this single PARACEST MRI contrast agent can accurately measure pH. PMID:22344877

  7. Vascular imaging with contrast agent in hard and soft tissues using microcomputed-tomography.

    PubMed

    Blery, P; Pilet, P; Bossche, A Vanden-; Thery, A; Guicheux, J; Amouriq, Y; Espitalier, F; Mathieu, N; Weiss, P

    2016-04-01

    Vascularization is essential for many tissues and is a main requisite for various tissue-engineering strategies. Different techniques are used for highlighting vasculature, in vivo and ex vivo, in 2-D or 3-D including histological staining, immunohistochemistry, radiography, angiography, microscopy, computed tomography (CT) or micro-CT, both stand-alone and synchrotron system. Vascularization can be studied with or without a contrast agent. This paper presents the results obtained with the latest Skyscan micro-CT (Skyscan 1272, Bruker, Belgium) following barium sulphate injection replacing the bloodstream in comparison with results obtained with a Skyscan In Vivo 1076. Different hard and soft tissues were perfused with contrast agent and were harvested. Samples were analysed using both forms of micro-CT, and improved results were shown using this new micro-CT. This study highlights the vasculature using micro-CT methods. The results obtained with the Skyscan 1272 are clearly defined compared to results obtained with Skyscan 1076. In particular, this instrument highlights the high number of small vessels, which were not seen before at lower resolution. This new micro-CT opens broader possibilities in detection and characterization of the 3-D vascular tree to assess vascular tissue engineering strategies. PMID:27002484

  8. Nanobubble Ultrasound Contrast Agents for Enhanced Delivery of Thermal Sensitizer to Tumors Undergoing Radiofrequency Ablation

    PubMed Central

    Perera, Reshani H.; Solorio, Luis; Wu, Hanping; Gangolli, Mihika; Silverman, Eric; Hernandez, Christopher; Peiris, Pubudu M.; Broome, Ann-Marie

    2013-01-01

    Purpose Pluronic has been shown to sensitize various tumor cell lines to chemotherapy and hyperthermia by altering the membrane fluidity, depleting ATP, and modulating the heat shock protein 70 expression. In our prior work, Pluronic was also used to formulate nanosized ultrasound contrast agents. In the current study we evaluate the use of these contrast agents as vehicles for image-guided delivery of Pluronic to improve outcomes of tumor radiofrequency (RF) ablation. Methods Lipid-shelled Pluronic nanobubbles were prepared and examined for size distribution, zeta potential, stability, biodistribution, accumulation of nanobubbles in the tumor, and treatment efficacy. LS174-T xenograft tumor-bearing mice were used to evaluate tumor growth suppression and measure treatment efficacy after RF ablation. Results The average diameter of Pluronic bubbles was 230 nm, and initial bubble echogenicity was 16 dB. In vitro, cells exposed to Pluronic nanobubbles exhibited low cytotoxicity in the absence of ultrasound, even if heat (43°C) was applied. When the cells were exposed to Pluronic nanobubbles, heat, and ultrasound; viability was significantly reduced. In vivo, tumors treated with ultrasound-modulated nanobubbles prior to RF ablation showed a significant reduction in growth compared to the RF alone (P<0.05). Conclusion Lipid and Pluronic-shelled, echogenic nanobubbles combined with ultrasound modulation can serve as an effective theranostic method for sensitization of tumors to RF ablation. PMID:23943542

  9. Evolution of contrast agents for ultrasound imaging and ultrasound-mediated drug delivery.

    PubMed

    Paefgen, Vera; Doleschel, Dennis; Kiessling, Fabian

    2015-01-01

    Ultrasound (US) is one of the most frequently used diagnostic methods. It is a non-invasive, comparably inexpensive imaging method with a broad spectrum of applications, which can be increased even more by using bubbles as contrast agents (CAs). There are various different types of bubbles: filled with different gases, composed of soft- or hard-shell materials, and ranging in size from nano- to micrometers. These intravascular CAs enable functional analyses, e.g., to acquire organ perfusion in real-time. Molecular analyses are achieved by coupling specific ligands to the bubbles' shell, which bind to marker molecules in the area of interest. Bubbles can also be loaded with or attached to drugs, peptides or genes and can be destroyed by US pulses to locally release the entrapped agent. Recent studies show that US CAs are also valuable tools in hyperthermia-induced ablation therapy of tumors, or can increase cellular uptake of locally released drugs by enhancing membrane permeability. This review summarizes important steps in the development of US CAs and introduces the current clinical applications of contrast-enhanced US. Additionally, an overview of the recent developments in US probe design for functional and molecular diagnosis as well as for drug delivery is given. PMID:26441654

  10. Transdermal Drug Delivery Aided by an Ultrasound Contrast Agent: An In Vitro Experimental Study

    PubMed Central

    Park, Donghee; Yoon, Jinhee; Park, Jingam; Jung, Byungjo; Park, Hyunjin; Seo, Jongbum

    2010-01-01

    Sonophoresis temporarily increases skin permeability such that medicine can be delivered transdermally. Cavitation is believed to be the predominant mechanism in sonophoresis. In this study, an ultrasound contrast agent (UCA) strategy was adopted instead of low frequency ultrasound to assure that cavitation occurred, and the efficacy of sonophoresis with UCA was quantitatively analyzed by optical measurements. The target drug used in this study was 0.1 % Definity® in 70% glycerol, which was delivered into porcine skin samples. Glycerol was used because it is an optical clearing agent, and the efficiency of glycerol delivery could be analyzed with optical measurements. The applied acoustic pressure was approximately 600 kPa at 1 MHz ultrasound with a 10% duty cycle for 60 minutes. Experimental results indicated that the measured relative contrast (RC) after sonophoresis with UCA was approximately 80% higher than RC after sonophoresis without UCA. In addition, the variance of RC was also reduced by more than 50% with the addition of a UCA. The use of a UCA appeared to increase cavitation, demonstrating that the use of a UCA can be effective in transdermal drug delivery (TDD). PMID:20448793

  11. Sub-second Proton Imaging of 13C Hyperpolarized Contrast Agents in Water

    PubMed Central

    Truong, Milton L.; Coffey, Aaron M.; Shchepin, Roman V.; Waddell, Kevin W.; Chekmenev, Eduard Y.

    2014-01-01

    Indirect proton detection of 13C hyperpolarized contrast agents potentially enables greater sensitivity. Presented here is a study of sub-second projection imaging of hyperpolarized 13C contrast agent addressing the obstacle posed by water suppression for indirect detection in vivo. Sodium acetate phantoms were used to develop and test water suppression and sub-second imaging with frequency selective RF pulses using spectroscopic and imaging indirect proton detection. A 9.8 mM aqueous solution of 13C PHIP hyperpolarized 2-hydroxyethyl-13C-propionate-d2,3,3 (HEP),

    ~25% was used for demonstration of indirect proton sub-second imaging detection. Balanced 2D FSSFP (Fast Steady State Free Precession) allowed recording proton images with FOV = 64×64 mm2 and spatial resolution 2×2 mm2 with total acquisition time of less than 0.2 s. In thermally polarized sodium 1-13C-acetate, 13C to 1H polarization transfer efficiency of 45.1% of the theoretically predicted values was observed in imaging detection corresponding to an 11 fold of overall sensitivity improvement compared to direct 13C FSSFP imaging. 13C to 1H polarization transfer efficiency of 27% was observed in imaging detection corresponding to a 3.25 fold sensitivity improvement compared to direct 13C FSSFP imaging with hyperpolarized HEP. The range of potential applications and limitations of this sub-second and ultra-sensitive imaging approach are discussed. PMID:24753438

  12. High relaxivity MRI contrast agents part 2: Optimization of inner- and second-sphere relaxivity

    PubMed Central

    Jacques, Vincent; Dumas, Stephane; Sun, Wei-Chuan; Troughton, Jeffrey S.; Greenfield, Matthew T.; Caravan, Peter

    2011-01-01

    Rationale and objectives The observed relaxivity of gadolinium based contrast agents has contributions from the water molecule(s) that bind directly to the gadolinium ion (inner-sphere water), long lived water molecules and exchangeable protons that make up the second-sphere of coordination, and water molecules that diffuse near the contrast agent (outer-sphere). Inner- and second-sphere relaxivity can both be increased by optimization of the lifetimes of the water molecules and protons in these coordination spheres, the rotational motion of the complex, and the electronic relaxation of the gadolinium ion. We sought to identify new high relaxivity contrast agents by systematically varying the donor atoms that bind directly to gadolinium to increase inner-sphere relaxivity and concurrently including substituents that influence the second-sphere relaxivity. Methods Twenty GdDOTA derivatives were prepared and their relaxivity determined in presence and absence of human serum albumin as a function of temperature and magnetic field. Data was analyzed to extract the underlying molecular parameters influencing relaxivity. Each compound had a common albumin-binding group and an inner-sphere donor set comprising the 4 tertiary amine N atoms from cyclen, an α-substituted acetate oxygen atom, two amide oxygen atoms, an inner-sphere water oxygen atom, and a variable donor group. Each amide nitrogen was substituted with different groups to promote hydrogen bonding with second-sphere water molecules. Results Relaxivites at 0.47T and 1.4T, 37 °C, in serum albumin ranged from 16.0 to 58.1 mM−1s−1 and from 12.3 to 34.8 mM−1s−1 respectively. The reduction of inner-sphere water exchange typical of amide donor groups could be offset by incorporating a phosphonate or phenolate oxygen atom donor in the first coordination sphere resulting in higher relaxivity. Amide nitrogen substitution with pendant phosphonate or carboxylate groups increased relaxivity by as much as 88

  13. Update on the safety and efficacy of commercial ultrasound contrast agents in cardiac applications

    PubMed Central

    Tracy, Melissa J; Feinstein, Steven B

    2015-01-01

    Ultrasound contrast agents (UCAs) are currently used throughout the world in both clinical and research settings. The concept of contrast-enhanced ultrasound imaging originated in the late 1960s, and the first commercially available agents were initially developed in the 1980s. Today's microbubbles are designed for greater utility and are used for both approved and off-label indications. In October 2007, the US Food and Drug Administration (FDA) imposed additional product label warnings that included serious cardiopulmonary reactions, several new disease-state contraindications, and a mandated 30 min post-procedure monitoring period for the agents Optison and Definity. These additional warnings were prompted by reports of cardiopulmonary reactions that were temporally related but were not clearly attributable to these UCAs. Subsequent published reports over the following months established not only the safety but also the improved efficacy of clinical ultrasound applications with UCAs. The FDA consequently updated the product labeling in June 2008 and reduced contraindications, although it continued to monitor select patients. In addition, a post-marketing program was proposed to the sponsors for a series of safety studies to further assess the risk of UCAs. Then in October 2011, the FDA leadership further downgraded the warnings after hearing the results of the post-marketing data, which revealed continued safety and improved efficacy. The present review focuses on the use of UCAs in today's clinical practice, including the approved indications, a variety of off-label uses, and the most recent data, which affirms the safety and efficacy of UCAs. PMID:26693339

  14. Crimson carrier, a long-acting contrast agent for in vivo near-infrared imaging of injured and diseased muscle.

    PubMed

    Prajapati, Suresh I; Martinez, Carlo O; Abraham, Jinu; McCleish, Amanda T; Michalek, Joel E; McManus, Linda M; Rubin, Brian P; Shireman, Paula K; Keller, Charles

    2010-08-01

    The near-infrared wavelengths (700-900 nm) are the most suitable optical window for light penetration and deep tissue imaging in small animals. Herein we report a near-infrared fluorescent contrast agent, crimson carrier, which acts as a blood pool contrast agent to detect and quantify injury and disease in live animals. After determining the excitation-emission spectra and pharmacokinetics, crimson carrier was injected into myoinjured mice to monitor their recovery. Crimson carrier was also used to image transgenic mice with spontaneous tumors. Crimson carrier has maximal excitation and emission wavelengths of 745 nm and 820 nm, respectively. Elimination occurs predominantly via urinary excretion. We demonstrate the utility of this contrast agent for serial imaging of traumatized muscle as well as muscle tumors. The unique long-acting pharmacokinetics and urinary excretion route characteristics make crimson carrier a contrast agent of choice for the visualization of tumors and injured muscle or other tissues in live animal studies. PMID:20544935

  15. Correction: Polyol synthesis, functionalisation, and biocompatibility studies of superparamagnetic iron oxide nanoparticles as potential MRI contrast agents

    NASA Astrophysics Data System (ADS)

    Hachani, Roxanne; Lowdell, Mark; Birchall, Martin; Hervault, Aziliz; Mertz, Damien; Begin-Colin, Sylvie; Thanh, Nguy&Ecirtil; N. Thi&Cmb. B. Dot; Kim

    2016-02-01

    Correction for `Polyol synthesis, functionalisation, and biocompatibility studies of superparamagnetic iron oxide nanoparticles as potential MRI contrast agents' by Roxanne Hachani et al., Nanoscale, 2015, DOI: 10.1039/c5nr03867g.

  16. Stimulus-responsive ultrasound contrast agents for clinical imaging: motivations, demonstrations, and future directions.

    PubMed

    Goodwin, Andrew P; Nakatsuka, Matthew A; Mattrey, Robert F

    2015-01-01

    Microbubble ultrasound contrast agents allow imaging of the vasculature with excellent resolution and signal-to-noise ratios. Contrast in microbubbles derives from their interaction with an ultrasound wave to generate signal at harmonic frequencies of the stimulating pulse; subtracting the elastic echo caused by the surrounding tissue can enhance the specificity of these harmonic signals significantly. The nonlinear acoustic emission is caused by pressure-driven microbubble size fluctuations, which in both theoretical descriptions and empirical measurements was found to depend on the mechanical properties of the shell that encapsulates the microbubble as well as stabilizes it against the surrounding aqueous environment. Thus biochemically induced switching between a rigid 'off' state and a flexible 'on' state provides a mechanism for sensing chemical markers for disease. In our research, we coupled DNA oligonucleotides to a stabilizing lipid monolayer to modulate stiffness of the shell and thereby induce stimulus-responsive behavior. In initial proof-of-principle studies, it was found that signal modulation came primarily from DNA crosslinks preventing the microbubble size oscillations rather than merely damping the signal. Next, these microbubbles were redesigned to include an aptamer sequence in the crosslinking strand, which not only allowed the sensing of the clotting enzyme thrombin but also provided a general strategy for sensing other soluble biomarkers in the bloodstream. Finally, the thrombin-sensitive microbubbles were validated in a rabbit model, presenting the first example of an ultrasound contrast agent that could differentiate between active and inactive clots for the diagnosis of deep venous thrombosis. PMID:25195785

  17. High-resolution wide-field imaging of perfused capillaries without the use of contrast agent

    PubMed Central

    Nelson, Darin A; Burgansky-Eliash, Zvia; Barash, Hila; Loewenstein, Anat; Barak, Adiel; Bartov, Elisha; Rock, Tali; Grinvald, Amiram

    2011-01-01

    Purpose: Assessment of capillary abnormalities facilitates early diagnosis, treatment, and follow-up of common retinal pathologies. Injected contrast agents like fluorescein are widely used to image retinal capillaries, but this highly effective procedure has a few disadvantages, such as untoward side effects, inconvenience of injection, and brevity of the time window for clear visualization. The retinal function imager (RFI) is a tool for monitoring retinal functions, such as blood velocity and oximetry, based on intrinsic signals. Here we describe the clinical use of hemoglobin in red blood cells (RBCs) as an intrinsic motion-contrast agent in the generation of detailed noninvasive capillary-perfusion maps (nCPMs). Patients and methods: Multiple series of nCPM images were acquired from 130 patients with diabetic retinopathy, vein occlusion, central serous retinopathy, age-related macular degeneration, or metabolic syndrome, as well as from 37 healthy subjects. After registration, pixel value distribution parameters were analyzed to locate RBC motion. Results: The RFI yielded nCPMs demonstrating microvascular morphology including capillaries in exquisite detail. Maps from the same subject were highly reproducible in repeated measurements, in as much detail and often better than that revealed by the very best fluorescein angiography. In patients, neovascularization and capillary nonperfusion areas were clearly observed. Foveal avascular zones (FAZ) were sharply delineated and were larger in patients with diabetic retinopathy than in controls (FAZ diameter: 641.5 ± 82.3 versus 463.7 ± 105 μm; P < 0.001). Also visible were abnormal vascular patterns, such as shunts and vascular loops. Conclusion: Optical imaging of retinal capillaries in human patients based on motion contrast is noninvasive, comfortable, safe, and can be repeated as often as required for early diagnosis, treatment guidance, and follow up of retinal disease progression. PMID:21887088

  18. Nanosized Ultrasound Enhanced-Contrast Agent for in Vivo Tumor Imaging via Intravenous Injection.

    PubMed

    Kim, Manse; Lee, Jong Hyun; Kim, Se Eun; Kang, Seong Soo; Tae, Giyoong

    2016-04-01

    To enhance the detection limit of ultrasound (US) imaging, ultrasound enhanced-contrast agents (UECAs) that can go preferentially to the target tissue such as a tumor and amplify the US signal have been developed. However, nanosized UECAs among various UECAs developed are very limited to clearly demonstrate proper ability for selective tumor detection by US imaging upon their intravenous injection. In this study, we prepared CaCO3 nanoparticles that were formed inside a flexible and biocompatible pluronic-based nanocarrier. This nanosized UECA was stable in serum-containing media and generated CO2, more preferentially at low pH; thus, it could be detected by US imaging. After intravenous injection into tumor-bearing mice, this nanosized UECA showed a significant US contrast enhancement at the tumor site in 1 h, in contrast to no change in the liver, followed by a rapid clearance from the body in 24 h. Therefore, the present nanosized UECA could be applied as an effective diagnostic modality for in vivo tumor imaging by ultrasonography. PMID:27010717

  19. TREG coated iron oxide nanoparticles as contrast agent for MRI in-vivo use

    NASA Astrophysics Data System (ADS)

    Gutierrez-Garcia, Eric; Hidalgo-Tobon, Silvia; Lopez, Ciro; Gonzalez-Rodriguez, Roberto; Coffer, Jeffery; De Celis Alonso, Benito; Dies Suarez, Pilar; Obregon, Manuel; Perez-Pena, Mario; Platas-Neri, Diana; Mendez-Rojas, Miguel

    2014-11-01

    Super-paramagnetic iron oxide nanoparticles (SPIONs) are of interest due to their great potential applications in diverse fields such as biomedicine. In this work we have prepared SPION nanoparticles using the polyol technique and characterized the magnetic properties of them for MRI in-vivo use. Nanoparticle preparation: All reagents were purchased from commercial sources (Sigma-Aldrich, St. Louis, USA) Iron (III) acetylacetonate, [Fe(acac)3], was used as the iron oxide precursor and thermally decomposed at high temperatures in triethyleneglycol (TREG). Nano-sized magnetite particles were prepared by an adaptation of the method proposed by Wei Cai et al[1-3]. A healthy rabbit was scanned on a clinical 1.5 T Philips MR scanner. Images were taken in 2D mode with a mFFE sequence. Relaxation time T2 was obtained from the MR images using a Matlab algorithm where the signal intensity decay was calculated at each image and then adjusted to a mono-exponential curve. Images were obtained before contrast injection, 24 hours and 36 hours following SPIONs administration. Signal decay at different Echo times for the prepared magnetic SPIONs, before and after contrast injection was measured. It was visualized a concentration of the agent contrast in brain and liver and the results were compared with images obtained from histopathology.

  20. Engineered Iron-Oxide-Based Nanoparticles as Enhanced T1 Contrast Agents for Efficient Tumor Imaging

    PubMed Central

    Zhou, Zijian; Wang, Lirong; Chi, Xiaoqin; Bao, Jianfeng; Yang, Lijiao; Zhao, Wenxiu; Chen, Zhong; Wang, Xiaomin; Chen, Xiaoyuan; Gao, Jinhao

    2013-01-01

    We report the design and synthesis of small-sized zwitterion-coated gadolinium-embedded iron oxide (GdIO) nanoparticles, which exhibit a strong T1 contrast effect for tumor imaging through enhanced permeation and retention effect and the ability to clear out of the body in living subjects. The combination of spin-canting effects and the collection of gadolinium species within small-sized GdIO nanoparticles led to a significantly enhanced T1 contrast effect. For example, GdIO nanoparticles with a diameter of ~4.8 nm exhibited a high r1 relaxivity of 7.85 mM−1 · S−1 and a low r2/r1 ratio of 5.24. After being coated with zwitterionic dopamine sulfonate molecules, the 4.8 nm GdIO nanoparticles showed a steady hydrodynamic diameter (~5.2 nm) in both PBS buffer and fetal bovine serum solution, indicating a low nonspecific protein absorption. This study provides a valuable strategy for the design of highly sensitive iron-oxide-based T1 contrast agents with relatively long circulation half-lives (~50 min), efficient tumor passive targeting (SKOV3, human ovarian cancer xenograft tumor as a model), and the possibility of rapid renal clearance after tumor imaging. PMID:23473444

  1. Liposomes Loaded with Hydrophobic Iron Oxide Nanoparticles: Suitable T₂ Contrast Agents for MRI.

    PubMed

    Martínez-González, Raquel; Estelrich, Joan; Busquets, Maria Antònia

    2016-01-01

    There has been a recent surge of interest in the use of superparamagnetic iron oxide nanoparticles (SPIONs) as contrast agents (CAs) for magnetic resonance imaging (MRI), due to their tunable properties and their low toxicity compared with other CAs such as gadolinium. SPIONs exert a strong influence on spin-spin T₂ relaxation times by decreasing the MR signal in the regions to which they are delivered, consequently yielding darker images or negative contrast. Given the potential of these nanoparticles to enhance detection of alterations in soft tissues, we studied the MRI response of hydrophobic or hydrophilic SPIONs loaded into liposomes (magnetoliposomes) of different lipid composition obtained by sonication. These hybrid nanostructures were characterized by measuring several parameters such as size and polydispersity, and number of SPIONs encapsulated or embedded into the lipid systems. We then studied the influence of acyl chain length as well as its unsaturation, charge, and presence of cholesterol in the lipid bilayer at high field strength (7 T) to mimic the conditions used in preclinical assays. Our results showed a high variability depending on the nature of the magnetic particles. Focusing on the hydrophobic SPIONs, the cholesterol-containing samples showed a slight reduction in r₂, while unsaturation of the lipid acyl chain and inclusion of a negatively charged lipid into the bilayer appeared to yield a marked increase in negative contrast, thus rendering these magnetoliposomes suitable candidates as CAs, especially as a liver CA. PMID:27472319

  2. Magnetic and relaxation properties of multifunctional polymer-based nanostructured bioferrofluids as MRI contrast agents.

    PubMed

    Amiri, Houshang; Bustamante, Rodney; Millán, Angel; Silva, Nuno J O; Piñol, Rafael; Gabilondo, Lierni; Palacio, Fernando; Arosio, Paolo; Corti, Maurizio; Lascialfari, Alessandro

    2011-12-01

    A series of maghemite/polymer composite ferrofluids with variable magnetic core size, which show a good efficiency as MRI contrast agents, are presented. These ferrofluids are biocompatible and can be proposed as possible platforms for multifunctional biomedical applications, as they contain anchoring groups for biofunctionalization, can incorporate fluorescent dyes, and have shown low cellular toxicity. The magnetic properties of the ferrofluids have been determined by means of magnetization and ac susceptibility measurements as a function of temperature and frequency. The NMR dispersion profiles show that the low frequency behavior of the longitudinal relaxivity r(1) is well described by the heuristic model of (1)H nuclear relaxation induced by superparamagnetic nanoparticles proposed by Roch and co-workers. The contrast efficiency parameter, i.e., the nuclear transverse relaxivity r(2), for samples with d > 10 nm assumes values comparable with or better than the ones of commercial samples, the best results obtained in particles with the biggest magnetic core, d = 15 nm. The contrast efficiency results are confirmed by in vitro MRI experiments at ν = 8.5 MHz, thus allowing us to propose a set of optimal microstructural parameters for multifunctional ferrofluids to be used in MRI medical diagnosis. PMID:21574179

  3. Tyrosinase-catalyzed melanin as a contrast agent for photoacoustic tomography

    NASA Astrophysics Data System (ADS)

    Krumholz, Arie; Chavez, Sarah; Yao, Junjie; Fleming, Timothy; Gillanders, William E.; Wang, Lihong V.

    2011-03-01

    It is difficult to distinguish between tumor cells and surrounding cells without staining as is done in histology. We developed tyrosinase-catalyzed melanin as a reporter gene for photoacoustic tomography. Tyrosinase is the primary enzyme responsible for the production of melanin and alone is sufficient to produce melanin in non-melanogenic cells. Two cell lines were created: a stably transfected HeLa line and a transiently transfected 293 line. A phantom experiment was performed with the 293 transfected cells 48 hours post transfection and the results compared with oxygenated whole blood, B16 melanoma and 293 control cells. An in vivo experiment was performed using the transfected HeLa cells xenografted into a nude mouse ear, and then imaged. The results show strong contrast for tyrosinase-catalyzed melanin in both the 293 cells in the tube phantom as well as the in vivo result showing melanin in a nude mouse ear. Transfection increased expression in 293 cells 159 fold and image contrast compared to blood by as much as 50 fold. Due to the strong signal obtained at longer wavelengths and the decrease of blood signal at the same wavelengths, tyrosinase catalyzed melanin is a good candidate as a molecular imaging contrast agent for photoacoustic tomography.

  4. Liposomes Loaded with Hydrophobic Iron Oxide Nanoparticles: Suitable T2 Contrast Agents for MRI

    PubMed Central

    Martínez-González, Raquel; Estelrich, Joan; Busquets, Maria Antònia

    2016-01-01

    There has been a recent surge of interest in the use of superparamagnetic iron oxide nanoparticles (SPIONs) as contrast agents (CAs) for magnetic resonance imaging (MRI), due to their tunable properties and their low toxicity compared with other CAs such as gadolinium. SPIONs exert a strong influence on spin-spin T2 relaxation times by decreasing the MR signal in the regions to which they are delivered, consequently yielding darker images or negative contrast. Given the potential of these nanoparticles to enhance detection of alterations in soft tissues, we studied the MRI response of hydrophobic or hydrophilic SPIONs loaded into liposomes (magnetoliposomes) of different lipid composition obtained by sonication. These hybrid nanostructures were characterized by measuring several parameters such as size and polydispersity, and number of SPIONs encapsulated or embedded into the lipid systems. We then studied the influence of acyl chain length as well as its unsaturation, charge, and presence of cholesterol in the lipid bilayer at high field strength (7 T) to mimic the conditions used in preclinical assays. Our results showed a high variability depending on the nature of the magnetic particles. Focusing on the hydrophobic SPIONs, the cholesterol-containing samples showed a slight reduction in r2, while unsaturation of the lipid acyl chain and inclusion of a negatively charged lipid into the bilayer appeared to yield a marked increase in negative contrast, thus rendering these magnetoliposomes suitable candidates as CAs, especially as a liver CA. PMID:27472319

  5. Self-assembled microbubbles as contrast agents for ultrasound/magnetic resonance dual-modality imaging.

    PubMed

    Song, Sheng; Guo, Heze; Jiang, Zequan; Jin, Yuqing; Wu, Ying; An, Xiao; Zhang, Zhaofeng; Sun, Kang; Dou, Hongjing

    2015-09-01

    In this work, superparamagnetic self-assembled microbubbles (SAMBs) consisting of "Poly(acrylic acid)-Iron oxide nanoparticles-Polyamine" sandwich-like shells and tetradecafluorohexane cores were fabricated by a template-free self-assembly approach. The SAMBs exhibit not only magnetic resonance (MR) T2 imaging functionality, but also ultrasound (US) image contrast, showing great potential as US/MR dual contrast agents. The diameters of the SAMBs can be tuned easily from 450nm to 1300nm by changing the precursor ratio, and this size variation directly affects their in vitro MRI and US signals. The SAMBs also exhibit in vivo contrast enhancement capabilities in rat li