  1. A Modified Epicardial Radiofrequency Ablation for Preoperative Atrial Fibrillation Combined With Isolated Aortic Valve Disease.

    PubMed

    Jiang, Zhaolei; Ma, Nan; Liu, Hao; Tang, Min; Ding, Fangbao; Bao, Chunrong; Mei, Ju

    2016-06-01

    Isolated aortic valve diseases can lead to atrial fibrillation (AF) by causing left atrium pressure overload and enlargement. At present, most patients with preoperative AF and isolated aortic valve disease have undergone a Cox-maze IV procedure through a left atriotomy under cardiopulmonary bypass with aortic cross-clamping. Here, we describe a novel modified epicardial radiofrequency ablation procedure performed on a beating heart without aortic cross-clamping or opening the left atrium. This technique has proved to be safe and feasible, with good clinical outcomes. It may be useful in selecting the best ablation approaches for patients with AF and aortic valve disease. PMID:27211963

  2. Aortic Valve Disease

    MedlinePlus

    ... Disease Tricuspid Valve Disease Cardiac Rhythm Disturbances Thoracic Aortic Aneurysm Pediatric and Congenital Heart Disease Heart abnormalities that ... Disease Tricuspid Valve Disease Cardiac Rhythm Disturbances Thoracic Aortic Aneurysm Aortic Valve Disease Overview The human heart has ...

  3. Transcatheter aortic valve implantation

    PubMed Central

    Oliemy, Ahmed

    2014-01-01

    Transcatheter aortic valve implantation was developed to offer a therapeutic solution to patients with severe symptomatic aortic stenosis who are not candidates for conventional aortic valve replacement. The improvement in transcatheter aortic valve implantation outcomes is still of concern in the areas of stroke, vascular injury, heart block, paravalvular regurgitation and valve durability. Concomitantly, the progress, both technical and in terms of material advances of transcatheter valve systems, as well as in patient selection, renders transcatheter aortic valve implantation an increasingly viable treatment for more and more patients with structural heart disease. PMID:25374670

  4. Incidence and Impact of Patient-Prosthesis Mismatch in Isolated Aortic Valve Surgery

    PubMed Central

    Dumani, Selman; Likaj, Ermal; Kacani, Andi; Dibra, Laureta; Petrela, Elizana; Beca, Vera; Refatllari, Ali

    2015-01-01

    AIM: The mains topics of this work are the incidence of patient-prosthesis mismatch and the influence in the early results of isolated aortic valve surgery. METHODS: In 193 patients isolated aortic valve surgery was performed. The study population was divided in three subgroups: 20 patients with severe, 131 patients with moderate and 42 patients without patient-prosthesis mismatch. The indexed effective orifice area was used to define the subgroups. Operative mortality and perioperative complications were considered the indicators of the early results of aortic valve surgery. RESULTS: The incidence of severe and moderate patient-prosthesis mismatch was respectively 10.3% and 67.8%. Hospital mortality and perioperative complications were: mortality 5% vs. 3.1% vs. 2.4% (p = 0.855), low cardiac output 5% vs. 6.9% vs. 4.8% (p = 0.861); pulmonary complications 5% vs. 3.1 vs. 0.0% (p = 0.430); exploration for bleeding 5% vs. 0.8% vs. 2.4% (p = 0.319); atrial fibrillation 30% vs. 19.8% vs. 11.9% (p = 0.225); wound infection 5% vs. 0.8% vs. 0.00% (p = 0.165), respectively for the group with severe, moderate and without patient-prosthesis mismatch. CONCLUSIONS: Patient-prosthesis mismatch is a common occurrence in aortic valve surgery. This phenomenon does not affect the early results of aortic valve surgery.

  5. Transcatheter aortic valve implantation.

    PubMed

    Nielsen, Hans Henrik Møller

    2012-12-01

    Transcatheter aortic valve implantation (TAVI) was introduced experimentally in 1989, based on a newly developed heart valve prosthesis - the stentvalve. The valve was invented by a Danish cardiologist named Henning Rud Andersen. The new valve was revolutionary. It was foldable and could be inserted via a catheter through an artery in the groin, without the need for heart lung machine. This allowed for a new valve implantation technique, much less invasive than conventional surgical aortic valve replacement (SAVR). Surgical aortic valve replacement is safe and improves symptoms along with survival. However, up to 1/3 of patients with aortic valve stenosis cannot complete the procedure due to frailty. The catheter technique was hoped to provide a new treatment option for these patients. The first human case was in 2002, but more widespread clinical use did not begin until 2006-2010. Today, in 2011, more than 40,000 valves have been implanted worldwide. Initially, because of the experimental character of the procedure, TAVI was reserved for patients who could not undergo SAVR due to high risk. The results in this group of patients were promising. The procedural safety was acceptable, and the patients experienced significant improvements in their symptoms. Three of the papers in this PhD-thesis are based on the outcome of TAVI at Skejby Hospital, in this high-risk population [I, II and IV]. Along with other international publications, they support TAVI as being superior to standard medical treatment, despite a high risk of prosthetic regurgitation. These results only apply to high-risk patients, who cannot undergo SAVR. The main purpose of this PhD study has been to investigate the quality of TAVI compared to SAVR, in order to define the indications for this new procedure. The article attached [V] describes a prospective clinical randomised controlled trial, between TAVI to SAVR in surgically amenable patients over 75 years of age with isolated aortic valve stenosis

  6. Minimally invasive aortic valve surgery.

    PubMed

    Castrovinci, Sebastiano; Emmanuel, Sam; Moscarelli, Marco; Murana, Giacomo; Caccamo, Giuseppa; Bertolino, Emanuela Clara; Nasso, Giuseppe; Speziale, Giuseppe; Fattouch, Khalil

    2016-09-01

    Aortic valve disease is a prevalent disorder that affects approximately 2% of the general adult population. Surgical aortic valve replacement is the gold standard treatment for symptomatic patients. This treatment has demonstrably proven to be both safe and effective. Over the last few decades, in an attempt to reduce surgical trauma, different minimally invasive approaches for aortic valve replacement have been developed and are now being increasingly utilized. A narrative review of the literature was carried out to describe the surgical techniques for minimally invasive aortic valve surgery and report the results from different experienced centers. Minimally invasive aortic valve replacement is associated with low perioperative morbidity, mortality and a low conversion rate to full sternotomy. Long-term survival appears to be at least comparable to that reported for conventional full sternotomy. Minimally invasive aortic valve surgery, either with a partial upper sternotomy or a right anterior minithoracotomy provides early- and long-term benefits. Given these benefits, it may be considered the standard of care for isolated aortic valve disease. PMID:27582764

  7. Minimally invasive aortic valve surgery

    PubMed Central

    Castrovinci, Sebastiano; Emmanuel, Sam; Moscarelli, Marco; Murana, Giacomo; Caccamo, Giuseppa; Bertolino, Emanuela Clara; Nasso, Giuseppe; Speziale, Giuseppe; Fattouch, Khalil

    2016-01-01

    Aortic valve disease is a prevalent disorder that affects approximately 2% of the general adult population. Surgical aortic valve replacement is the gold standard treatment for symptomatic patients. This treatment has demonstrably proven to be both safe and effective. Over the last few decades, in an attempt to reduce surgical trauma, different minimally invasive approaches for aortic valve replacement have been developed and are now being increasingly utilized. A narrative review of the literature was carried out to describe the surgical techniques for minimally invasive aortic valve surgery and report the results from different experienced centers. Minimally invasive aortic valve replacement is associated with low perioperative morbidity, mortality and a low conversion rate to full sternotomy. Long-term survival appears to be at least comparable to that reported for conventional full sternotomy. Minimally invasive aortic valve surgery, either with a partial upper sternotomy or a right anterior minithoracotomy provides early- and long-term benefits. Given these benefits, it may be considered the standard of care for isolated aortic valve disease. PMID:27582764

  8. Aortic valve decalcification revisited.

    PubMed

    Marty, A T; Mufti, S; Murabit, I

    1989-11-01

    A 75-year-old woman with a small calcified aortic root, severe aortic stenosis and triple vessel coronary artery disease developed angina at rest. Aortic valve decalcification and quadruple aorto-coronary bypass were done as her aortic root was too small and calcified to do anything else. Postoperative clinical and hemodynamic results have been excellent. Literature review supports application of this therapy in selected patients with trileaflet senescent aortic stenosis. PMID:2614067

  9. Aortic valve surgery - open

    MedlinePlus

    ... choose to have your aortic valve surgery at a center that does many of these procedures. ... DA, Harken AH. Acquired heart disease: valvular. In: Townsend CM, ... Textbook of Cardiovascular Medicine . 10th ed. Philadelphia, PA: ...

  10. Sutureless aortic valve replacement

    PubMed Central

    Phan, Kevin

    2015-01-01

    The increasing incidence of aortic stenosis and greater co-morbidities and risk profiles of the contemporary patient population has driven the development of minimally invasive aortic valve surgery and percutaneous transcatheter aortic valve implantation (TAVI) techniques to reduce surgical trauma. Recent technological developments have led to an alternative minimally invasive option which avoids the placement and tying of sutures, known as “sutureless” or rapid deployment aortic valves. Potential advantages for sutureless aortic prostheses include reducing cross-clamp and cardiopulmonary bypass (CPB) duration, facilitating minimally invasive surgery and complex cardiac interventions, whilst maintaining satisfactory hemodynamic outcomes and low paravalvular leak rates. However, given its recent developments, the majority of evidence regarding sutureless aortic valve replacement (SU-AVR) is limited to observational studies and there is a paucity of adequately-powered randomized studies. Recently, the International Valvular Surgery Study Group (IVSSG) has formulated to conduct the Sutureless Projects, set to be the largest international collaborative group to investigate this technology. This keynote lecture will overview the use, the potential advantages, the caveats, and current evidence of sutureless and rapid deployment aortic valve replacement (AVR). PMID:25870807

  11. [Isolated Pulmonary Valve Endocarditis in a Patient with Aortic Regurgitation and Patent Foramen Ovale;Report of a Case].

    PubMed

    Doi, Toshio; Gyoten, Takayuki; Sakata, Kimimasa; Nagura, Saori; Yamashita, Akio; Fukahara, Kazuaki; Kotoh, Keiju; Yoshimura, Naoki

    2016-07-01

    Isolated pulmonary valve endocarditis is an extremely rare clinical condition. Here, we report a case of pulmonary valve endocarditis caused by methicillin-resistant Staphylococcus aureus (MRSA). An 84-year-old man with a history of aortic regurgitation and patent foramen ovale was admitted to our hospital due to fever of unknown origin for 4 weeks' duration. MRSA was detected in his blood cultures. Transthoracic echocardiography demonstrated a mobile vegetation attached to the pulmonary valve, moderate to severe aortic regurgitation, and patent foramen ovale with left-to-right shunt. After 30-days' treatment with vancomycin, gentamicin and rifampicin, he defervesced and blood cultures became negative. At surgery, a large vegetation was still attached to the pulmonary valve, but the leaflets remained with minimum damage. Aortic valve replacement, direct closure of the patent foramen ovale, and simple resection of the vegetation were performed. The postoperative course was uneventful. PMID:27365067

  12. Aortic valve replacement in rheumatoid aortic incompetence.

    PubMed Central

    Devlin, A B; Goldstraw, P; Caves, P K

    1978-01-01

    Rheumatoid aortic valve disease is uncommon. and there are few reports of valve replacement in this condition. Aortic valve replacement and partial pericardiectomy was performed in a patient with acute rheumatoid aortitis and aortic incompetence. Previous reports suggest that any patient with rheumatoid arthritis who develops cardiac symptoms should be carefully assessed for surgically treatable involvement of the pericardium or heart valves. Images PMID:725829

  13. Transcatheter Aortic Valve Implantation.

    PubMed

    Malaisrie, S Chris; Iddriss, Adam; Flaherty, James D; Churyla, Andrei

    2016-05-01

    Severe aortic stenosis (AS) is a life-threatening condition when left untreated. Aortic valve replacement (AVR) is the gold standard treatment for the majority of patients; however, transcatheter aortic valve implantation/replacement (TAVI/TAVR) has emerged as the preferred treatment for high-risk or inoperable patients. The concept of transcatheter heart valves originated in the 1960s and has evolved into the current Edwards Sapien and Medtronic CoreValve platforms available for clinical use. Complications following TAVI, including cerebrovascular events, perivalvular regurgitation, vascular injury, and heart block have decreased with experience and evolving technology, such that ongoing trials studying TAVI in lower risk patients have become tenable. The multidisciplinary team involving the cardiac surgeon and cardiologist plays an essential role in patient selection, procedural conduct, and perioperative care. PMID:27021619

  14. Bicuspid aortic valve

    MedlinePlus

    ... is unclear, but it is the most common congenital heart disease . It often runs in families. The bicuspid aortic ... A.M. Editorial team. Related MedlinePlus Health Topics Congenital Heart Defects Heart Valve Diseases Browse the Encyclopedia A.D.A.M., Inc. ...

  15. Aortic or Mitral Valve Replacement With the Biocor and Biocor Supra

    ClinicalTrials.gov

    2016-03-09

    Aortic Valve Insufficiency; Aortic Valve Regurgitation; Aortic Valve Stenosis; Aortic Valve Incompetence; Mitral Valve Insufficiency; Mitral Valve Regurgitation; Mitral Valve Stenosis; Mitral Valve Incompetence

  16. Aortic Valve Sparing in Different Aortic Valve and Aortic Root Conditions.

    PubMed

    David, Tirone E

    2016-08-01

    The development of aortic valve-sparing operations (reimplantation of the aortic valve and remodeling of the aortic root) expanded the surgical armamentarium for treating patients with aortic root dilation caused by a variety of disorders. Young adults with aortic root aneurysms associated with genetic syndromes are ideal candidates for reimplantation of the aortic valve, and the long-term results have been excellent. Incompetent bicuspid aortic valves with dilated aortic annuli are also satisfactorily treated with the same type of operation. Older patients with ascending aortic aneurysm and aortic insufficiency secondary to dilated sinotubular junction and a normal aortic annulus can be treated with remodeling of the aortic root or with reimplantation of the aortic valve. The first procedure is simpler, and both procedures are likely equally effective. As with any heart valve-preserving procedure, patient selection and surgical expertise are keys to successful and durable repairs. PMID:27491910

  17. Recent advances in aortic valve disease: highlights from a bicuspid aortic valve to transcatheter aortic valve replacement.

    PubMed

    Augoustides, John G T; Wolfe, Yanika; Walsh, Elizabeth K; Szeto, Wilson Y

    2009-08-01

    There have been major advances in the management of aortic valve disease. Because bicuspid aortic valve is common and predicts an increased risk of adverse aortic events, these patients merit aortic surveillance and consideration for ascending aortic replacement when its diameter exceeds 4.0 cm. Serial quantitative echocardiographic analysis, as compared with traditional clinical markers, can result in better timing of surgical intervention for aortic regurgitation. Furthermore, echocardiographic analysis of aortic regurgitation can classify the mechanism based on cusp mobility to guide aortic valve repair. In aortic root replacement, aortic valve preservation with reimplantation is a mainstream surgical option in Marfan syndrome to offer freedom from valve-related anticoagulation. Prosthetic aortic root replacement has further alternatives with the introduction of the aortic neosinus design and acceptable clinical outcomes with the porcine xenograft. Because aortic valve prosthesis-patient mismatch (PPM) may adversely affect patient outcome, its perioperative prevention is important. Furthermore, significant functional mitral regurgitation in association with aortic stenosis often resolves after aortic valve replacement. Echocardiographic assessment of the aortic valve must include valve area because the transaortic pressure gradient may be low in severe stenosis. Aortic valve replacement with partial sternotomy is safe and offers a reasonable less invasive alternative. Transcatheter aortic valve replacement, whether transfemoral or transapical, has revolutionized aortic valve replacement; it remains a major theme in the specialty for 2009 and beyond. PMID:19497768

  18. Aortic valve annuloplasty: new single suture technique.

    PubMed

    Schöllhorn, Joachim; Rylski, Bartosz; Beyersdorf, Friedhelm

    2014-06-01

    Reconstruction strategies for aortic valve insufficiency in the presence of aortic annulus dilatation are usually surgically challenging. We demonstrate a simple, modified Taylor technique of downsizing and stabilization of the aortic annulus using a single internal base suture. Since April 2011, 22 consecutive patients have undergone safe aortic valve annuloplasty. No reoperations for aortic valve insufficiency and no deaths occurred. PMID:24882316

  19. Evaluation of platelet count after isolated biological aortic valve replacement with Freedom Solo bioprosthesis†

    PubMed Central

    Miceli, Antonio; Gilmanov, Daniyar; Murzi, Michele; Parri, Maria S.; Cerillo, Alfredo G.; Bevilacqua, Stefano; Farneti, Pier A.; Glauber, Mattia

    2012-01-01

    OBJECTIVE The risk of thrombocytopenia in patients undergoing aortic valve replacement (AVR) with the Freedom Solo (FS) bioprosthesis is controversial. The aim of our study was to evaluate the postoperative evolution of platelet count and function after AVR in patients undergoing isolated biological AVR with FS. METHODS Between May 2005 and June 2010, 322 patients underwent isolated biological AVR. Of these, 116 patients received FS and were compared with 206 patients who received biological valves. Platelet count, mean platelet volume (MPV), and platelet distribution width (PDW) were evaluated at baseline (T0), first (T1), second (T2), and fifth (T3) postoperative days, respectively. RESULTS Overall in-hospital mortality was 1.5% with no difference between the two groups. Thirty-seven (11.5%) patients developed thrombocytopenia. FS implantation was associated with a higher incidence of thrombocytopenia compared with the control group (24.1% vs 4.4%, p < 0.0001). Patients in the FS group showed a lower platelet count than the control group at T1 (99.4 ± 38 × 103 μl−1 vs 122.5 ± 41.6 × 103 μl−1, p < 0.001), T2 (79.7 ± 36.3 × 103 μl−1 vs 122.5 ± 43.3 × 103 μl−1, p < 0.001) and T3 (86.6 ± 57.4 × 103 μl−1 vs 158.4 ± 55.8 × 103 μl−1, p < 0.001). Moreover, the FS group also had a higher MPV (11.6 ± 0.9 fl vs 11 ± 1 fl, p < 0.001) and higher PDW (15.1 ± 2.3 fl vs 13.9 ± 2.1 fl, p < 0.001) at T3. In a multivariable analysis, FS (p < 0.0001), body surface area (p < 0.0001), cardiopulmonary bypass time (p = 0.003), and lower preoperative platelet counts (p = 0.006) were independent predictors of thrombocytopenia. CONCLUSIONS The FS valve might increase the risk of thrombocytopenia and platelet activation, in the absence of adverse clinical events. Prospective randomized studies on platelet function need to confirm our data. PMID:21664141

  20. Biomechanics of the pulmonary autograft valve in the aortic position.

    PubMed Central

    Gorczynski, A; Trenkner, M; Anisimowicz, L; Gutkowski, R; Drapella, A; Kwiatkowska, E; Dobke, M

    1982-01-01

    Pulmonary autograft valve replacement has been simulated by implanting the pulmonary valve into the aortic position of the same cadaver heart from both human and porcine sources. The forces acting on the pulmonary valve leaflets have been calculated on the basis of a triaxial ellipsoid mathematical model. These forces on the pulmonary autograft valve were shown to be essentially similar to those previously reported for aortic valve leaflets. Biomechanical measurements have been made on the simulated autograft valves and on the isolated pulmonary valve cusps. The tensile strengths of the pulmonary valve cusps in both circumferential and radial directions were roughly three times greater than those of aortic valve cusps. This indicated the ability of the pulmonary valves to accept, ab initio, aortic valve closing pressures. Pressure-induced changes in dimension, calculated on the basis of diameters of the simulated pulmonary autograft root, also indicated that the distensibility of the autograft valve was limited. It reached a maximum at 30 mm Hg (4 kPa) without any suggestion of further distension to the point of distortion and incompetence. The combination of the calculated forces acting on the valve and the biomechanical measurements have shown that pulmonary valves used as autograft aortic valve replacements are able to tolerate aortic pressures from the time of implantation. These experimental results from simulated autografts support the clinical use of this valve over the past 13 years. PMID:7135295

  1. Aortic regurgitation after transcatheter aortic valve replacement.

    PubMed

    Werner, Nikos; Sinning, Jan-Malte

    2014-01-01

    Paravalvular aortic regurgitation (AR) negatively affects prognosis following transcatheter aortic valve replacement (TAVR). As transcatheter heart valves (THV) are anchored using a certain degree of oversizing at the level of the aortic annulus, incomplete stent frame expansion because of heavily annular calcifications, suboptimal placement of the prosthesis, and/or annulus-prosthesis size-mismatch can contribute to paravalvular AR with subsequent increased mortality risk. Echocardiography is essential to differentiate between transvalvular and paravalvular AR and to further elucidate the etiology of AR during the procedure. However, because echocardiographic quantification of AR in TAVR patients remains challenging, especially in the implantation situation, a multimodal approach to the evaluation of AR with use of hemodynamic measurements and imaging modalities is useful to precisely quantify the severity of AR immediately after valve deployment. "Next-generation" THVs are already on the market and first results show that paravalvular AR related to design modifications (eg, paravalvular space-fillers, full repositionability) are rarely seen in these valve types.  PMID:24632758

  2. Aortic valve surgery - open

    MedlinePlus

    ... There are two main types of new valves: Mechanical, made of man-made materials, such as titanium ... Mechanical heart valves do not fail often. However, blood clots can develop on them. If a blood ...

  3. Surgical Aortic Valvuloplasty Versus Balloon Aortic Valve Dilatation in Children.

    PubMed

    Donald, Julia S; Konstantinov, Igor E

    2016-09-01

    Balloon aortic valve dilatation (BAD : is assumed to provide the same outcomes as surgical aortic valvuloplasty (SAV). However, the development of precise modern surgical valvuloplasty techniques may result in better long-term durability of the aortic valve repair. This review of the recent literature suggests that current SAV provides a safe and durable repair. Furthermore, primary SAV appears to have greater freedom from reintervention and aortic valve replacement when compared to BAD. PMID:27587493

  4. Giant Thoracic Aneurysm Following Valve Replacement for Bicuspid Aortic Valve.

    PubMed

    Tran, Cao; Ul Haq, Ehtesham; Nguyen, Ngoc; Omar, Bassam

    2015-01-01

    Bicuspid aortic valve is a common congenital anomaly associated with aortopathy, which can cause aortic root dilatation, necessitating regular screening if the aortic root is > 4.0 cm. Despite the low absolute incidence of aortic complications associated with bicuspid aortic valve in the general population, the consequences of such complications for an individual patient can be devastating. Herein we propose a balanced algorithm that incorporates recommendations from the three major guidelines for follow-up imaging of the aortic root and ascending thoracic aorta in patients with a bicuspid aortic valve, maintaining the current recommendations with regard to surgical thresholds. PMID:26827748

  5. [MINIMALLY INVASIVE AORTIC VALVE REPLACEMENT].

    PubMed

    Tabata, Minoru

    2016-03-01

    Minimally invasive aortic valve replacement (MIAVR) is defined as aortic valve replacement avoiding full sternotomy. Common approaches include a partial sternotomy right thoracotomy, and a parasternal approach. MIAVR has been shown to have advantages over conventional AVR such as shorter length of stay and smaller amount of blood transfusion and better cosmesis. However, it is also known to have disadvantages such as longer cardiopulmonary bypass and aortic cross-clamp times and potential complications related to peripheral cannulation. Appropriate patient selection is very important. Since the procedure is more complex than conventional AVR, more intensive teamwork in the operating room is essential. Additionally, a team approach during postoperative management is critical to maximize the benefits of MIAVR. PMID:27295772

  6. Aortic valve allografts in sheep

    PubMed Central

    Borrie, John; Hill, G. L.

    1968-01-01

    Some of the mechnical and biological problems surrounding the use of fresh allograft inverted aortic valves as mitral valve substitutes are described. Certain aspects of the problem have been studied experimentally. In three sheep `fresh' aortic valve allografts were inserted, using cardiopulmonary bypass, into the main pulmonary artery, and were observed from 5 to 7 months after operation. The animals survived normally. Their normal pulmonary valves remained in situ. The technique is described. At subsequent necropsy, macroscopically the valves were found to be free from vegetation, and the cusps were pliable and apparently normal. Microscopically, the supporting allograft myocardium showed necrosis and early calcification. The valve cusp showed hyalinization of collagen, although beneath the endocardium this hyalinized collagen contained moderate numbers of fibroblasts with no evidence of proliferation. The endocardium and arterial intima of the allograft showed evidence of ingrowth from adjacent normal host endocardial tissues. The allograft itself was invested in a loose layer of fibro-fatty tissue, which, in view of the necrotic state of the graft myocardium, could well have been a reparative reaction rather than a homograft reaction. It is concluded that, although the cusps could function normally, the necrosis of the myocardium might in time lead to late failure of the graft. Further studies with the valve inserted at mitral level are indicated. Images PMID:5656757

  7. Brucellosis complicated by aortic valve endocarditis.

    PubMed

    Skillington, P D; McGiffin, D C; Kemp, R; Bett, J H; Holt, G; Forgan-Smith, R

    1988-12-01

    A 30 year old veterinary surgeon developed a febrile illness with serological evidence of Brucellosis. He was known to have aortic valve disease and during the course of the illness, the clinical features of endocarditis became evident, with a vegetation visible echocardiographically on the aortic valve. Because of persisting fever despite appropriate antibiotic therapy, aortic valve replacement with a viable cryopreserved allograft aortic valve was undertaken. Organisms consistent with Brucella species were demonstrated in the excised vegetation. The patient received a six week course of antibiotics and his post-operative course was uneventful. PMID:3250411

  8. Decellularized aortic homografts for aortic valve and aorta ascendens replacement†

    PubMed Central

    Tudorache, Igor; Horke, Alexander; Cebotari, Serghei; Sarikouch, Samir; Boethig, Dietmar; Breymann, Thomas; Beerbaum, Philipp; Bertram, Harald; Westhoff-Bleck, Mechthild; Theodoridis, Karolina; Bobylev, Dmitry; Cheptanaru, Eduard; Ciubotaru, Anatol; Haverich, Axel

    2016-01-01

    OBJECTIVES The choice of valve prosthesis for aortic valve replacement (AVR) in young patients is challenging. Decellularized pulmonary homografts (DPHs) have shown excellent results in pulmonary position. Here, we report our early clinical results using decellularized aortic valve homografts (DAHs) for AVR in children and mainly young adults. METHODS This prospective observational study included all 69 patients (44 males) operated from February 2008 to September 2015, with a mean age of 19.7 ± 14.6 years (range 0.2–65.3 years). In 18 patients, a long DAH was used for simultaneous replacement of a dilated ascending aorta as an extended aortic root replacement (EARR). Four patients received simultaneous pulmonary valve replacement with DPH. RESULTS Thirty-nine patients (57%) had a total of 62 previous operations. The mean aortic cross-clamp time in isolated cases was 129 ± 41 min. There was 1 conduit-unrelated death. The mean DAH diameter was 22.4 ± 3.7 mm (range, 10–29 mm), the average peak gradient was 14 ± 15 mmHg and the mean aortic regurgitation grade (0.5 = trace, 1 = mild) was 0.6 ± 0.5. The mean effective orifice area (EOA) of 25 mm diameter DAH was 3.07 ± 0.7 cm2. DAH annulus z-values were 1.1 ± 1.1 at implantation and 0.7 ± 1.3 at the last follow-up. The last mean left ventricle ejection fraction and left ventricle end diastolic volume index was 63 ± 7% and 78 ± 16 ml/m2 body surface area, respectively. To date, no dilatation has been observed at any level of the graft during follow-up; however, the observational time is short (140.4 years in total, mean 2.0 ± 1.8 years, maximum 7.6 years). One small DAH (10 mm at implantation) had to be explanted due to subvalvular stenosis and developing regurgitation after 4.5 years and was replaced with a 17 mm DAH without complication. No calcification of the explanted graft was noticed intraoperatively and after histological analysis, which revealed extensive recellularization without inflammation

  9. Intraoperative tracking of aortic valve plane.

    PubMed

    Nguyen, D L H; Garreau, M; Auffret, V; Le Breton, H; Verhoye, J P; Haigron, P

    2013-01-01

    The main objective of this work is to track the aortic valve plane in intra-operative fluoroscopic images in order to optimize and secure Transcatheter Aortic Valve Implantation (TAVI) procedure. This paper is focused on the issue of aortic valve calcifications tracking in fluoroscopic images. We propose a new method based on the Tracking-Learning-Detection approach, applied to the aortic valve calcifications in order to determine the position of the aortic valve plane in intra-operative TAVI images. This main contribution concerns the improvement of object detection by updating the recursive tracker in which all features are tracked jointly. The approach has been evaluated on four patient databases, providing an absolute mean displacement error less than 10 pixels (≈2mm). Its suitability for the TAVI procedure has been analyzed. PMID:24110703

  10. Mechanical versus biological aortic valve replacement strategies.

    PubMed

    Reineke, D; Gisler, F; Englberger, L; Carrel, T

    2016-04-01

    Aortic valve replacement (AVR) is the most frequently performed procedure in valve surgery. The controversy about the optimal choice of the prosthetic valve is as old as the technique itself. Currently there is no perfect valve substitute available. The main challenge is to choose between mechanical and biological prosthetic valves. Biological valves include pericardial (bovine, porcine or equine) and native porcine bioprostheses designed in stented, stentless and sutureless versions. Homografts and pulmonary autografts are reserved for special indications and will not be discussed in detail in this review. We will focus on the decision making between artificial biological and mechanical prostheses, respectively. The first part of this article reviews guideline recommendations concerning the choice of aortic prostheses in different clinical situations while the second part is focused on novel strategies in the treatment of patients with aortic valve pathology. PMID:26678683

  11. Bicuspid Aortic Valve: Unlocking the Morphogenetic Puzzle.

    PubMed

    Longobardo, Luca; Jain, Renuka; Carerj, Scipione; Zito, Concetta; Khandheria, Bijoy K

    2016-08-01

    Although bicuspid aortic valve is the most common congenital abnormality, it is perhaps erroneous to consider this disease one clinical entity. Rather, it may be useful to consider it a cluster of diseases incorporating different phenotypes, etiologies, and pathogenesis. Discussion of bicuspid aortic valve can be difficult because there is no clear consensus on a phenotypic description among authors, and many classification schemes have been proposed. The literature suggests that different phenotypes have different associations and clinical manifestations. In addition, recent studies suggest a genetic basis for the disease, yet few genes have so far been described. Furthermore, recent scientific literature has been focusing on the increased risk of aortic aneurysms, but the pathogenesis of bicuspid aortic valve aortopathy is still unclear. The aim of this paper is to review the current evidence about the unsolved issues around bicuspid aortic valve. PMID:27059385

  12. Quadricuspid aortic valve with ruptured sinus of Valsalva.

    PubMed

    Akerem Khan, Shamruz Khan; Tamin, Syahidah Syed; Burkhart, Harold M; Araoz, Philip A; Young, Phillip M

    2013-02-01

    We present a case of a 24-year-old woman who was diagnosed with quadricuspid aortic valve with ruptured sinus of Valsalva. Quadricuspid aortic valve is a rare congenital cardiac anomaly. The recognition of quadricuspid aortic valve has clinical significance as it causes aortic valve dysfunction, and is often associated with other congenital cardiac abnormalities. We showed the important role of multimodality imaging in diagnosing a quadricuspid aortic valve associated with ruptured sinus of Valsalva. PMID:22874066

  13. Geometry of aortic heart valves. [prosthetic design

    NASA Technical Reports Server (NTRS)

    Karara, H. M.

    1975-01-01

    Photogrammetric measurements of the surface topography of the aortic valves obtained from silicon rubber molds of freshly excised human aortic valves are presented. The data are part of an investigation into the design of a new prosthetic valve which will be a central-flow device, like the real valve and unlike previous central-occluding prostheses. Since the maximum stress on the heart valve is induced when the valve is closed and subject to diastolic back-pressure, it was decided to determine the valve geometry during diastole. That is, the molds were formed by pouring the rubber down the excised aortas, causing the valves to close. The molds were made under different pressures (20-120 torr); photogrammetry served as a vehicle for the assessment of the mold topography through the following outputs: digital models, surface profiles, and contour maps.

  14. First direct aortic retrievable transcatheter aortic valve implantation in humans.

    PubMed

    Chandrasekhar, Jaya; Glover, Chris; Labinaz, Marino; Ruel, Marc

    2014-11-01

    We describe 2 cases in which transcatheter aortic valve implantation was performed with a Portico prosthesis (St Jude Medical, St Paul, MN) through a direct aortic approach. In 1 of the cases, prosthesis retrieval was needed during the procedure and was essential to the successful outcome. This is the first report, to our knowledge, of direct aortic Portico prosthesis implantation, and it highlights the significance of the retrievable nature of this device. PMID:25442452

  15. Minimally Invasive Transcatheter Aortic Valve Replacement (TAVR)

    MedlinePlus Videos and Cool Tools

    Watch a Broward Health surgeon perform a minimally invasive Transcatheter Aortic Valve Replacement (TAVR) Click Here to view the BroadcastMed, Inc. Privacy Policy and Legal Notice © 2016 BroadcastMed, Inc. All rights reserved.

  16. Nanobacteria-associated calcific aortic valve stenosis.

    PubMed

    Jelic, Tomislav M; Chang, Ho-Huang; Roque, Rod; Malas, Amer M; Warren, Stafford G; Sommer, Andrei P

    2007-01-01

    Calcific aortic valve stenosis is the most common valvular disease in developed countries, and the major reason for operative valve replacement. In the US, the current annual cost of this surgery is approximately 1 billion dollars. Despite increasing morbidity and mortality, little is known of the cellular basis of the calcifications, which occur in high-perfusion zones of the heart. The case is presented of a patient with calcific aortic valve stenosis and colonies of progressively mineralized nanobacteria in the fibrocalcific nodules of the aortic cusps, as revealed by transmission electron microscopy. Consistent with their outstanding bioadhesivity, nanobacteria might serve as causative agents in the development of calcific aortic valve stenosis. PMID:17315391

  17. Mitral and aortic regurgitation following transcatheter aortic valve replacement

    PubMed Central

    Szymański, Piotr; Hryniewiecki, Tomasz; Dąbrowski, Maciej; Sorysz, Danuta; Kochman, Janusz; Jastrzębski, Jan; Kukulski, Tomasz; Zembala, Marian

    2016-01-01

    Objective To analyse the impact of postprocedural mitral regurgitation (MR), in an interaction with aortic regurgitation (AR), on mortality following transcatheter aortic valve implantation (TAVI). Methods To assess the interaction between MR and AR, we compared the survival rate of patients (i) without both significant MR and AR versus (ii) those with either significant MR or significant AR versus (iii) with significant MR and AR, all postprocedure. 381 participants of the Polish Transcatheter Aortic Valve Implantation Registry (166 males (43.6%) and 215 females (56.4%), age 78.8±7.4 years) were analysed. Follow-up was 94.1±96.5 days. Results Inhospital and midterm mortality were 6.6% and 10.2%, respectively. Significant MR and AR were present in 16% and 8.1% patients, including 3.1% patients with both significant MR and AR. Patients with significant versus insignificant AR differed with respect to mortality (log rank p=0.009). This difference was not apparent in a subgroup of patients without significant MR (log rank p=0.80). In a subgroup of patients without significant AR, there were no significant differences in mortality between individuals with versus without significant MR (log rank p=0.44). Significant MR and AR had a significant impact on mortality only when associated with each other (log rank p<0.0001). At multivariate Cox regression modelling concomitant significant MR and AR were independently associated with mortality (OR 3.2, 95% CI 1.54 to 5.71, p=0.002). Conclusions Significant MR or AR postprocedure, when isolated, had no impact on survival. Combined MR and AR had a significant impact on a patient's prognosis. PMID:26908096

  18. Aortic valve repair for papillary fibroelastoma.

    PubMed

    Di Marco, Luca; Al-Basheer, Amin; Glineur, David; Oppido, Guido; Di Bartolomeo, Roberto; El-Khoury, Gebrine

    2006-05-01

    We report the case of aortic valve-papillary fibroelastoma in a 66-year-old Belgian woman with a previous single episode of cerebral transient ischemic attack. Transthoracic two-dimensional echocardiography revealed a small mass adherent to the noncoronary cusp of the valve, which was confirmed by transesophageal echocardiography. Indication for surgery was performed because of a previous cerebral transient ischemic attack and for its potential risk of cerebral and coronary embolization. Surgical excision of the mass was performed with the need for glutaraldehyde-treated autologous pericardial patch repair of the aortic cusp. Intraoperative and postoperative transesophageal echocardiography both showed the valve to be competent. Postoperative recovery was uneventful. After a review of the literature, we conclude that, even if asymptomatic, and independent of their size, aortic valve papillary fibroelastomas justify surgical excision for their potential to systemic embolization. Moreover, we believe that a valve-sparing approach might be feasible with no recurrence after complete excision. PMID:16645416

  19. Quadricuspid Aortic Valve: A Rare Congenital Cause of Aortic Insufficiency

    PubMed Central

    Vasudev, Rahul; Shah, Priyank; Bikkina, Mahesh; Shamoon, Fayez

    2016-01-01

    Quadricuspid aortic valve (QAV) is a rare congenital cardiac anomaly causing aortic regurgitation usually in the fifth to sixth decade of life. Earlier, the diagnosis was mostly during postmortem or intraoperative, but now with the advent of better imaging techniques such as transthoracic echocardiography, transesophageal echocardiography (TEE), and cardiac magnetic resonance imaging, more cases are being diagnosed in asymptomatic patients. We present a case of a 39-year-old male who was found to have QAV, with the help of TEE, while undergoing evaluation for a diastolic murmur. The patient was found to have Type B QAV with moderate aortic regurgitation. We also present a brief review of classification, pathophysiology, and embryological basis of this rare congenital anomaly. The importance of diagnosing QAV lies in the fact that majority of these patients will require surgery for aortic regurgitation and close follow-up so that aortic valve replacement/repair is done before the left ventricular decompensation occurs. PMID:27195176

  20. Advances in Transcatheter Aortic Valve Replacement

    PubMed Central

    Kleiman, Neal S.; Reardon, Michael J.

    2016-01-01

    Transcatheter aortic valve replacement (TAVR) is becoming widely used for the treatment of symptomatic severe aortic stenosis in patients with high surgical risk. Data from The PARTNER Trial (Placement of AoRtic TraNscathetER Valves) and the Medtronic CoreValve® U.S. Pivotal Investigational Device Exemption trial indicate that survival for extreme-risk patients is superior to best medical therapy and equivalent or superior to surgical aortic valve replacement (SAVR), although long-term durability remains unknown. Paravalvular leak remains higher in TAVR than SAVR, as does permanent pacemaker implantation in self-expanding valves. New-generation valves are addressing these issues, especially for paravalvular leak. There is strong evidence that TAVR is appropriate for both extreme-risk and high-risk patients with symptomatic severe aortic stenosis, and the continued development of new valves are making implantation more reliable. This review discusses the studies supporting the use of TAVR and explores current advances in the field. PMID:27127560

  1. A Novel Method for Screening Children with Isolated Bicuspid Aortic Valve.

    PubMed

    Gharehbaghi, Arash; Dutoit, Thierry; Sepehri, Amir A; Kocharian, Armen; Lindén, Maria

    2015-12-01

    This paper presents a novel processing method for heart sound signal: the statistical time growing neural network (STGNN). The STGNN performs a robust classification by merging supervised and unsupervised statistical methods to overcome non-stationary behavior of the signal. By combining available preprocessing and segmentation techniques and the STGNN classifier, we build an automatic tool for screening children with isolated BAV, the congenital heart malformation which can lead to serious cardiovascular lesions. Children with BAV (22 individuals) and healthy condition (28 individuals) are subjected to the study. The performance of the STGNN is compared to that of a time growing neural network (CTGNN) and a conventional support vector (CSVM) machine, using balanced repeated random sub sampling. The average of the accuracy/sensitivity is estimated to be 87.4/86.5 for the STGNN, 81.8/83.4 for the CTGNN, and 72.9/66.8 for the CSVM. Results show that the STGNN offers better performance and provides more immunity to the background noise as compared to the CTGNN and CSVM. The method is implementable in a computer system to be employed in primary healthcare centers to improve the screening accuracy. PMID:26577485

  2. Challenging transfemoral valve-in-valve implantation in a degenerated stentless bioprosthetic aortic valve.

    PubMed

    Halapas, A; Chrissoheris, M; Spargias, Konstantinos

    2014-08-01

    Bioprosthetic heart valves are often preferred over mechanical valves as they may preclude the need for anticoagulation. Reoperation is the standard treatment for structural failure of bioprosthetic valves; however, it carries significant risk especially in inoperable elderly patients. Valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) seems to be an effective and promising procedure in patients with degenerated bioprosthetic aortic valves avoiding the risks associated with the use of cardioplegia and redo cardiac surgery. We report an interesting case of a high-risk 74-year-old patient with a degenerated Sorin Freedom Solo stentless valve treated successfully with ViV TAVR. PMID:25091103

  3. Minimally Invasive Versus Conventional Aortic Valve Replacement

    PubMed Central

    Attia, Rizwan Q.; Hickey, Graeme L.; Grant, Stuart W.; Bridgewater, Ben; Roxburgh, James C.; Kumar, Pankaj; Ridley, Paul; Bhabra, Moninder; Millner, Russell W. J.; Athanasiou, Thanos; Casula, Roberto; Chukwuemka, Andrew; Pillay, Thasee; Young, Christopher P.

    2016-01-01

    Objective Minimally invasive aortic valve replacement (MIAVR) has been demonstrated as a safe and effective option but remains underused. We aimed to evaluate outcomes of isolated MIAVR compared with conventional aortic valve replacement (CAVR). Methods Data from The National Institute for Cardiovascular Outcomes Research (NICOR) were analyzed at seven volunteer centers (2006–2012). Primary outcomes were in-hospital mortality and midterm survival. Secondary outcomes were postoperative length of stay as well as cumulative bypass and cross-clamp times. Propensity modeling with matched cohort analysis was used. Results Of 307 consecutive MIAVR patients, 151 (49%) were performed during the last 2 years of study with a continued increase in numbers. The 307 MIAVR patients were matched on a 1:1 ratio. In the matched CAVR group, there was no statistically significant difference in in-hospital mortality [MIAVR, 4/307,(1.3%); 95% confidence interval (CI), 0.4%–3.4% vs CAVR, 6/307 (2.0%); 95% CI, 0.8%–4.3%; P = 0.752]. One-year survival rates in the MIAVR and CAVR groups were 94.4% and 94.6%, respectively. There was no statistically significant difference in midterm survival (P = 0.677; hazard ratio, 0.90; 95% CI, 0.56–1.46). Median postoperative length of stay was lower in the MIAVR patients by 1 day (P = 0.009). The mean cumulative bypass time (94.8 vs 91.3 minutes; P = 0.333) and cross-clamp time (74.6 vs 68.4 minutes; P = 0.006) were longer in the MIAVR group; however, this was significant only in the cross-clamp time comparison. Conclusions Minimally invasive aortic valve replacement is a safe alternative to CAVR with respect to operative and 1-year mortality and is associated with a shorter postoperative stay. Further studies are required in high-risk (logistic EuroSCORE > 10) patients to define the role of MIAVR. PMID:26926521

  4. Has percutaneous aortic valve replacement taken center stage in the treatment of aortic valve disease?

    PubMed

    Kumar, Gideon Praveen; Cui, Fangsen; Mathew, Lazar; Leo, Hwa Liang

    2013-01-01

    Modern biomedical advances have propelled percutaneous valve replacement into an effective and powerful therapy for many heart valve diseases, especially aortic valve stenosis. Experiences so far suggest that outcomes for new percutaneous valve replacement surgery compare favorably with that of traditional valve surgery in selected patients with severe symptomatic aortic stenosis. The inception of percutaneous aortic valve replacement (PAVR) began in 1992 when the potential for treating valve diseases was demonstrated through a modern technique of endoluminal deployment of a catheter-mounted crimped stented heart valve in an animal model. The first successful demonstration of such novel technique of surgical replacement of a heart valve was performed in 2002, when valve implantation in a patient with aortic stenosis was reported. Despite initial stumbles and a perception of being an uphill task, PAVR has emerged as one of the breakthroughs in surgical procedures. More than 1500 citations were found in PubMed, half of which were available after 2011. This is primarily because more than 50,000 procedures are being performed in more than 40 countries worldwide, with encouraging outcomes, and several stented valves have been launched in the market. This review provides a detailed analysis of the current state of the art of PAVR. Moreover, a competitive landscape of various devices available in the market and their design considerations, biomaterial selections, and overall hemodynamic performance are presented. PMID:24941416

  5. Pump isolation valve

    DOEpatents

    Kinney, Calvin L.; Wetherill, Todd M.

    1983-08-02

    The pump isolation valve provides a means by which the pump may be selectively isolated from the remainder of the coolant system while being compatible with the internal hydraulic arrangement of the pump during normal operation of the pump. The valve comprises a valve cylinder disposed around the pump and adjacent to the last pump diffuser with a turning vane attached to the lower end of the valve cylinder in a manner so as to hydraulically match with the discharge diffuser. The valve cylinder is connected to a drive means for sliding the valve cylinder relative to the diffuser support cylinder so as to block flow in either direction through the discharge diffuser when the valve is in the closed position and to aid in the flow of the coolant from the discharge diffuser by means of the turning vane when the valve is in the open position.

  6. Aortic valve surgery - minimally invasive

    MedlinePlus

    ... There are two main types of new valves: Mechanical, made of man-made materials, such as titanium ... Mechanical heart valves do not fail often. However, blood clots can develop on them. If a blood ...

  7. WUnicuspid Aortic Valve- An Uncommon Anomaly With a Common Presentation.

    PubMed

    Sitwala, Puja; Abusara, Ashraf; Ladia, Vatsal; Ladia, Vatsal; Panchal, Hemang B; Raudat, Charles; Paul, Timir K

    2016-01-01

    Unicuspid aortic valve (UAV), which is a rare congenital anomaly, usually presents as aortic stenosis and/or aortic regurgitation. Here we present a case of UAV co-existent with an ascending aortic aneurysm. A 26-year-old male with no significant past medical history presented to the hospital after two episodes of syncope. Transthoracic echocardiogram showed an ejection fraction of 62%, severely stenotic aortic valve, and moderate aortic regurgitation. Computed tomography revealed calcification of the aortic valve, compatible with aortic stenosis and aneurysm of the ascending aorta measuring 4.3 cm in diameter. He underwent successful aortic valve replacement and repair of ascending aortic aneurysm. He recovered well without any complications. This case suggests that any young patient who presents with syncope, aortic stenosis would be a differential and further workup by any available non-invasive modality needs to be performed. PMID:27383857

  8. Aortic valve replacement with sutureless and rapid deployment aortic valve prostheses

    PubMed Central

    Berretta, Paolo; Di Eusanio, Marco

    2016-01-01

    Aortic valve stenosis is the most common valve disease in the western world. Over the past few years the number of aortic valve replacement (AVR) interventions has increased with outcomes that have been improved despite increasing age of patients and increasing burden of comorbidities. However, despite such excellent results and its well-established position, conventional AVR has undergone great development over the previous two decades. Such progress, by way of less invasive incisions and use of new technologies, including transcatheter aortic valve implantation and sutureless valve prostheses, is intended to reduce the traumatic impact of the surgical procedure, thus fulfilling lower risk patients' expectations on the one hand, and extending the operability toward increasingly high-risk patients on the other. Sutureless and rapid deployment aortic valves are biological, pericardial prostheses that anchor within the aortic annulus with no more than three sutures. The sutureless prostheses, by avoiding the passage and the tying of the sutures, significantly reduce operative times and may improve outcomes. However, there is still a paucity of robust, evidence-based data on the role and performance of sutureless AVR. Therefore, strongest long-term data, randomized studies and registry data are required to adequately assess the durability and long-term outcomes of sutureless aortic valve replacement. PMID:27582765

  9. Aortic valve replacement with sutureless and rapid deployment aortic valve prostheses.

    PubMed

    Berretta, Paolo; Di Eusanio, Marco

    2016-09-01

    Aortic valve stenosis is the most common valve disease in the western world. Over the past few years the number of aortic valve replacement (AVR) interventions has increased with outcomes that have been improved despite increasing age of patients and increasing burden of comorbidities. However, despite such excellent results and its well-established position, conventional AVR has undergone great development over the previous two decades. Such progress, by way of less invasive incisions and use of new technologies, including transcatheter aortic valve implantation and sutureless valve prostheses, is intended to reduce the traumatic impact of the surgical procedure, thus fulfilling lower risk patients' expectations on the one hand, and extending the operability toward increasingly high-risk patients on the other. Sutureless and rapid deployment aortic valves are biological, pericardial prostheses that anchor within the aortic annulus with no more than three sutures. The sutureless prostheses, by avoiding the passage and the tying of the sutures, significantly reduce operative times and may improve outcomes. However, there is still a paucity of robust, evidence-based data on the role and performance of sutureless AVR. Therefore, strongest long-term data, randomized studies and registry data are required to adequately assess the durability and long-term outcomes of sutureless aortic valve replacement. PMID:27582765

  10. The Effects of Positioning of Transcatheter Aortic Valve on Fluid Dynamics of the Aortic Root

    PubMed Central

    Su, Jimmy L; Kheradvar, Arash

    2015-01-01

    Transcatheter aortic valve implantation is a novel treatment for severe aortic valve stenosis. Due to the recent use of this technology and the procedural variability, there is very little data that quantifies the hemodynamic consequences of variations in valve placement. Changes in aortic wall stresses and fluid retention in the sinuses of Valsalva can have a significant effect on the clinical response a patient has to the procedure. By comprehensively characterizing complex flow in the sinuses of Valsalva using Digital Particle Image Velocimetry and an advanced heart flow simulator, various positions of a deployed transcatheter valve with respect to a bioprosthetic aortic valve (valve-in-valve) were tested in vitro. Displacements of the transcatheter valve were axial and directed below the simulated native valve annulus. It was determined that for both blood residence time and aortic Reynolds stresses, it is optimal to have the annulus of the transcatheter valve deployed as close to the aortic valve annulus as possible. PMID:25010918

  11. Transcatheter, valve-in-valve transapical aortic and mitral valve implantation, in a high risk patient with aortic and mitral prosthetic valve stenoses

    PubMed Central

    Ramakrishna, Harish; DeValeria, Patrick A.; Sweeney, John P.; Mookaram, Farouk

    2015-01-01

    Transcatheter valve implantation continues to grow worldwide and has been used principally for the nonsurgical management of native aortic valvular disease-as a potentially less invasive method of valve replacement in high-risk and inoperable patients with severe aortic valve stenosis. Given the burden of valvular heart disease in the general population and the increasing numbers of patients who have had previous valve operations, we are now seeing a growing number of high-risk patients presenting with prosthetic valve stenosis, who are not potential surgical candidates. For this high-risk subset transcatheter valve delivery may be the only option. Here, we present an inoperable patient with severe, prosthetic valve aortic and mitral stenosis who was successfully treated with a trans catheter based approach, with a valve-in-valve implantation procedure of both aortic and mitral valves. PMID:25849702

  12. Coronary Ostial Stenosis after Aortic Valve Replacement

    PubMed Central

    Ziakas, Antonios G.; Economou, Fotios I.; Charokopos, Nicholas A.; Pitsis, Antonios A.; Parharidou, Despina G.; Papadopoulos, Thomas I.; Parharidis, Georgios E.

    2010-01-01

    Coronary ostial stenosis is a rare but potentially serious sequela after aortic valve replacement. It occurs in the left main or right coronary artery after 1% to 5% of aortic valve replacement procedures. The clinical symptoms are usually severe and may appear from 1 to 6 months postoperatively. Although the typical treatment is coronary artery bypass grafting, patients have been successfully treated by means of percutaneous coronary intervention. Herein, we present the cases of 2 patients in whom coronary ostial stenosis developed after aortic valve replacement. In the 1st case, a 72-year-old man underwent aortic valve replacement and bypass grafting of the saphenous vein to the left anterior descending coronary artery. Six months later, he experienced a non-ST-segment-elevation myocardial infarction. Coronary angiography revealed a critical stenosis of the right coronary artery ostium. In the 2nd case, a 78-year-old woman underwent aortic valve replacement and grafting of the saphenous vein to an occluded right coronary artery. Four months later, she experienced unstable angina. Coronary angiography showed a critical left main coronary artery ostial stenosis and occlusion of the right coronary artery venous graft. In each patient, we performed percutaneous coronary intervention and deployed a drug-eluting stent. Both patients were asymptomatic on 6-to 12-month follow-up. We attribute the coronary ostial stenosis to the selective ostial administration of cardioplegic solution during surgery. We conclude that retrograde administration of cardioplegic solution through the coronary sinus may reduce the incidence of postoperative coronary ostial stenosis, and that stenting may be an efficient treatment option. PMID:20844624

  13. Transcatheter aortic valve implantation today and tomorrow.

    PubMed

    Wenaweser, Peter; Praz, Fabien; Stortecky, Stefan

    2016-01-01

    Aortic stenosis is the most common valvular heart disease in Western industrial countries (including Switzerland) with a prevalence of about 5% in the population aged 75 and over. If left untreated, symptomatic patients have a rate of death of more than 50% within 2 years. As a result of age and elevated surgical risk, an important proportion of elderly patients are not referred to surgery. Thus, the introduction of transcatheter aortic valve implantation (TAVI) in 2002 has initiated a paradigm shift in the treatment of patients with symptomatic, severe aortic stenosis. The early technical and procedural success of this minimal invasive treatment in high-risk patients has promoted further innovation and development of transcatheter heart valve (THV) systems during the last 13 years. Downsizing of the delivery catheters along with technical improvements aiming to reduce postprocedural paravalvular regurgitation have resulted in a significant reduction in mortality. As a consequence, TAVI is nowadays established as safe and effective treatment for selected inoperable and high-risk patients. Ongoing studies are investigating the outcome of intermediate risk patients allocated to either surgical aortic valve replacement (SAVR) or TAVI. Despite these advancements, some specific areas of concern still require attention and need further investigations including conduction disturbances, valve degeneration and antithrombotic management. Although the off-label use of TAVI devices in the mitral, tricuspid or pulmonary position has recently developed, important limitations still apply and careful patient selection remains crucial. This review aims to summarise the available clinical evidence of transcatheter aortic valve treatment during the last 13 years and to provide a glimpse of future technologies. PMID:26999727

  14. In the era of the valve-in-valve: is transcatheter aortic valve implantation (TAVI) in sutureless valves feasible?

    PubMed Central

    Saia, Francesco; Pellicciari, Giovanni; Phan, Kevin; Ferlito, Marinella; Dall’Ara, Gianni; Di Bartolomeo, Roberto; Marzocchi, Antonio

    2015-01-01

    Sutureless aortic valve implantation has emerged as an innovative alternative for treatment of aortic stenosis. By avoiding the placement of sutures, this approach aims to improve surgical outcomes by facilitating less traumatic minimally invasive approaches and reducing cross-clamp and cardiopulmonary bypass duration. However, the absence of sutures may have detrimental effects after sutureless interventions, including paravalvular leakages, valve dislocation, and stent-infolding. Transcatheter aortic valve-in-valve implantation (A-ViV) is emerging as a valuable procedure in patients with dysfunctioning biological aortic valves who are deemed inoperable with conventional surgery. Here we present the first-in-man case of trans-femoral implant of a balloon expandable aortic valve in a leaking sutureless self-expandable valve. PMID:25870827

  15. In the era of the valve-in-valve: is transcatheter aortic valve implantation (TAVI) in sutureless valves feasible?

    PubMed

    Di Eusanio, Marco; Saia, Francesco; Pellicciari, Giovanni; Phan, Kevin; Ferlito, Marinella; Dall'Ara, Gianni; Di Bartolomeo, Roberto; Marzocchi, Antonio

    2015-03-01

    Sutureless aortic valve implantation has emerged as an innovative alternative for treatment of aortic stenosis. By avoiding the placement of sutures, this approach aims to improve surgical outcomes by facilitating less traumatic minimally invasive approaches and reducing cross-clamp and cardiopulmonary bypass duration. However, the absence of sutures may have detrimental effects after sutureless interventions, including paravalvular leakages, valve dislocation, and stent-infolding. Transcatheter aortic valve-in-valve implantation (A-ViV) is emerging as a valuable procedure in patients with dysfunctioning biological aortic valves who are deemed inoperable with conventional surgery. Here we present the first-in-man case of trans-femoral implant of a balloon expandable aortic valve in a leaking sutureless self-expandable valve. PMID:25870827

  16. [Acute coronary artery dissection after aortic valve replacement].

    PubMed

    Machado, Fernando de Paula; Sampaio, Roney Orismar; Mazzucato, Fernanda Lopez; Tarasoutchi, Flávio; Spina, Guilherme Sobreira; Grinberg, Max

    2010-02-01

    Late aortic dissection can occur after aortic valve replacement surgery, but rarely in the first postoperative month. Coronary artery dissection is rare and usually occurs after coronary angiography. We report a rare case of coronary artery dissection followed by myocardial infarction in the immediate postoperative period of a successful aortic valve replacement with a good postoperative evolution. PMID:20428604

  17. Transfemoral Valve-in-Valve Transcatheter Aortic Valve Implantation (TAVI) in a Patient With Previous Endovascular Aortic Repair (EVAR).

    PubMed

    Ruparelia, Neil; Panoulas, Vasileios F; Frame, Angela; Nathan, Anthony W; Ariff, Ben; Jaffer, Usman; Sutaria, Nilesh; Chukwuemeka, Andrew; Mikhail, Ghada W; Malik, Iqbal S

    2016-07-01

    A 90-year-old man presented with increasing exertional breathlessness. He had previous implantation of a Perimount bioprosthetic aortic valve (Edwards Lifesciences) and coronary artery bypass graft surgery. Due to severe transvalvular bioprosthetic regurgitation with preserved left ventricular dimensions and ejection fraction, the heart team decided on valve-in- valve transcatheter aortic valve implantation via the transfemoral route in view of the patient's prohibitively high surgical and anesthetic risk. The patient had an uncomplicated recovery and was symptomatically much improved at 3-month follow-up. PMID:27342209

  18. Transcatheter aortic valve insertion (TAVI): a review

    PubMed Central

    Morgan-Hughes, G; Roobottom, C

    2014-01-01

    The introduction of transcatheter aortic valve insertion (TAVI) has transformed the care provided for patients with severe aortic stenosis. The uptake of this procedure is increasing rapidly, and clinicians from all disciplines are likely to increasingly encounter patients being assessed for or having undergone this intervention. Successful TAVI heavily relies on careful and comprehensive imaging assessment, before, during and after the procedure, using a range of modalities. This review outlines the background and development of TAVI, describes the nature of the procedure and considers the contribution of imaging techniques, both to successful intervention and to potential complications. PMID:24258463

  19. [Nocardia endocarditis in aortic and tricuspid native valves].

    PubMed

    Chain, Sergio; Luciardi, Hector; Feldman, Gabriela; Berman, Sofia; Estrella, Cristina

    2007-01-01

    Nocardia endocarditis in native valve is an uncommon infection that usually arises in immunodepressed patients. We report a 51-year-old man diagnosed as having Nocardia endocarditis in aortic and tricuspid native valves, which received antimicrobial therapy and required aortic valve replacement. In 6 month follow up the patient remained asymptomatic with good clinical evolution. PMID:17628917

  20. Imaging and minimally invasive aortic valve replacement

    PubMed Central

    Loor, Gabriel

    2015-01-01

    Cardiovascular imaging has been the most important tool allowing for innovation in cardiac surgery. There are now a variety of approaches available for treating aortic valve disease, including standard sternotomy, minimally invasive surgery, and percutaneous valve replacement. Minimally invasive cardiac surgery relies on maximizing exposure within a limited field of view. The complexity of this approach is increased as the relationship between the great vessels and the bony thorax varies between individuals. Ultimately, the success of minimally invasive surgery depends on appropriate choices regarding the type and location of the incision, cannulation approach, and cardioprotection strategy. These decisions are facilitated by preoperative imaging, which forms the focus of this review. PMID:25694979

  1. International Expert Consensus on Sutureless and Rapid Deployment Valves in Aortic Valve Replacement Using Minimally Invasive Approaches

    PubMed Central

    Glauber, Mattia; Moten, Simon C.; Quaini, Eugenio; Solinas, Marco; Folliguet, Thierry A.; Meuris, Bart; Miceli, Antonio; Oberwalder, Peter J.; Rambaldini, Manfredo; Teoh, Kevin H. T.; Bhatnagar, Gopal; Borger, Michael A.; Bouchard, Denis; Bouchot, Olivier; Clark, Stephen C.; Dapunt, Otto E.; Ferrarini, Matteo; Fischlein, Theodor J. M.; Laufer, Guenther; Mignosa, Carmelo; Millner, Russell; Noirhomme, Philippe; Pfeiffer, Steffen; Ruyra-Baliarda, Xavier; Shrestha, Malakh Lal; Suri, Rakesh M.; Troise, Giovanni; Gersak, Borut

    2016-01-01

    Objective To define the benefit of sutureless and rapid deployment valves in current minimally invasive approaches in isolated aortic valve replacement. Methods A panel of 28 international experts with expertise in both minimally invasive aortic valve replacement and rapid deployment valves was constituted. After thorough literature review, the experts rated evidence-based recommendations in a modified Delphi approach. Results No guideline could be retrieved. Thirty-three clinical trials and 9 systematic reviews could be identified for detailed text analysis to obtain a total of 24 recommendations. After rating by the experts 12, final recommendations were identified: preoperative computed tomographic scan as well as intraoperative transesophageal echocardiography are highly recommended. Suitable annular sizes are 19 to 27 mm. There is a contraindication for bicuspid valves only for type 0 and for annular abscess or destruction due to infective endocarditis. The use of sutureless and rapid deployment valves reduces extracorporeal circulation and aortic cross-clamp time and leads to less early complications as prolonged ventilation, blood transfusion, atrial fibrillation, pleural effusions, paravalvular leakages and aortic regurgitation, and renal replacement therapy, respectively. These clinical outcomes result in reduced intensive care unit and hospital stay and reduced costs. The use of sutureless and rapid deployment valves will lead to a higher adoption rate of minimally invasive approaches in aortic valve replacement. Respect should be taken to a necessary short learning curve for both sutureless and minimally invasive programs. Conclusions Sutureless and rapid deployment aortic valve replacement together with minimally invasive approaches offers an attractive option in aortic valve placement for patients requiring biological valve replacement. PMID:27540996

  2. Early Outcomes of Sutureless Aortic Valves

    PubMed Central

    Hanedan, Muhammet Onur; Mataracı, İlker; Yürük, Mehmet Ali; Özer, Tanıl; Sayar, Ufuk; Arslan, Ali Kemal; Ziyrek, Uğur; Yücel, Murat

    2016-01-01

    Background In elderly high-risk surgical patients, sutureless aortic valve replacement (AVR) should be an alternative to standard AVR. The potential advantages of sutureless aortic prostheses include reducing cross-clamping and cardiopulmonary bypass (CPB) time and facilitating minimally invasive surgery and complex cardiac interventions, while maintaining satisfactory hemodynamic outcomes and low rates of paravalvular leakage. The current study reports our single-center experience regarding the early outcomes of sutureless aortic valve implantation. Methods Between October 2012 and June 2015, 65 patients scheduled for surgical valve replacement with symptomatic aortic valve disease and New York Heart Association function of class II or higher were included to this study. Perceval S (Sorin Biomedica Cardio Srl, Sallugia, Italy) and Edwards Intuity (Edwards Lifesciences, Irvine, CA, USA) valves were used. Results The mean age of the patients was 71.15±8.60 years. Forty-four patients (67.7%) were female. The average preoperative left ventricular ejection fraction was 56.9±9.93. The CPB time was 96.51±41.27 minutes and the cross-clamping time was 60.85±27.08 minutes. The intubation time was 8.95±4.19 hours, and the intensive care unit and hospital stays were 2.89±1.42 days and 7.86±1.42 days, respectively. The mean quantity of drainage from chest tubes was 407.69±149.28 mL. The hospital mortality rate was 3.1%. A total of five patients (7.69%) died during follow-up. The mean follow-up time was 687.24±24.76 days. The one-year survival rate was over 90%. Conclusion In the last few years, several models of valvular sutureless bioprostheses have been developed. The present study evaluating the single-center early outcomes of sutureless aortic valve implantation presents the results of an innovative surgical technique, finding that it resulted in appropriate hemodynamic conditions with acceptable ischemic time. PMID:27298793

  3. New frontiers in aortic therapy: focus on current trials and devices in transcatheter aortic valve replacement.

    PubMed

    Gutsche, Jacob T; Patel, Prakash A; Walsh, Elizabeth K; Sophocles, Aris; Chern, Sy-Yeu S; Jones, David B; Anwaruddin, Saif; Desai, Nimesh D; Weiss, Stuart J; Augoustides, John G T

    2015-04-01

    The first decade of clinical experience with transcatheter aortic valve replacement since 2002 saw the development of 2 main valve systems, namely the Edwards Sapien balloon-expandable valve series and the Medtronic self-expanding CoreValve. These 2 valve platforms now have achieved commercial approval and application worldwide in patients with severe aortic stenosis whose perioperative risk for surgical intervention is high or extreme. In the second decade of transcatheter aortic valve replacement, clinical experience and refinements in valve design have resulted in clinical drift towards lower patient risk cohorts. There are currently 2 major trials, PARTNER II and SURTAVI, that are both evaluating the role of transcatheter aortic valve replacement in intermediate-risk patient cohorts. The results from these landmark trials may usher in a new clinical paradigm for transcatheter aortic valve replacement in its second decade. PMID:25572322

  4. Minimally invasive aortic valve replacement: the “Miami Method”

    PubMed Central

    2015-01-01

    For patients undergoing aortic valve replacement (AVR), a minimally invasive approach performed via a right anterior thoracotomy is the preferred method at our institution. This method has evolved over a 10-year span, being applied to over 1,500 patients with the commitment of one surgeon seeking to offer a simplistic and reproducible minimally invasive alternative. We believe that this is truly the least invasive approach to the aortic valve since it avoids sternal invasion. By virtue of being less traumatic, the morbidity is diminished and therefore the recovery is enhanced. We believe that this approach is most beneficial in the high risk patient such as the elderly, the obese, those with chronic obstructive pulmonary, chronic kidney disease and those requiring re-operative surgery. This method has proven to be safe and effective in all patients requiring isolated AVR surgery. The only relative exclusion criteria would be a porcelain aorta with the inability to cannulate the patient. PMID:25694981

  5. Absent Aortic Valve in DiGeorge Syndrome.

    PubMed

    Bertsch, Elizabeth C; Minturn, Lucy; Gotteiner, Nina L; Ernst, Linda M

    2016-01-01

    A 20-week-old fetus with the 22q11.2 deletion characteristic of DiGeorge syndrome is described with vertebral segmentation abnormalities and complex cardiovascular anomalies including an absent aortic valve. This is only the second known case of absent aortic valve in association with DiGeorge syndrome. We discuss the association of absent aortic valve with other conotruncal defects and the utility of fetal echocardiography in the diagnosis of DiGeorge syndrome. PMID:26230226

  6. Thrombocytosis following splenectomy and aortic valve replacement for idiopathic thrombocytopaenic purpura with bicuspid aortic valve

    PubMed Central

    Katiyar, Sarika; Ganjsinghani, Payal Kamlesh; Jain, Rajnish Kumar

    2015-01-01

    Idiopathic thrombocytopaenic purpura (ITP) patients are at high risk for complications during and after cardiac surgeries involving cardiopulmonary bypass. The main clinical problem of primary ITP is an increased risk of bleeding although bleeding may not always be present. More recently, thrombosis has become appreciated as another potential complication of the procedure. We report a 22-year-old female patient with ITP with bicuspid aortic valve and splenomegaly, who underwent uncomplicated aortic valve replacement and splenectomy simultaneously. She was readmitted with chest pain due to coronary thrombosis following splenectomy which made the management difficult. We describe our experience in managing this patient who presented with thrombotic complication rather than bleeding in post-operative period and the challenges met in maintaining appropriate anticoagulation for aortic valve replacement as well as thrombosis, post-splenectomy PMID:26379295

  7. Fetal cardiac circulation in isolated aortic atresia assessed with ultrasound.

    PubMed

    Sayit, Aslı Tanrıvermiş; Ipek, Ali; Kurt, Aydın; Aghdasi, Bayan G; Arslan, Halil; Gümüş, Mehmet

    2012-01-01

    Congenital heart diseases are common, with an incidence of more than 8 in 1000 live births. Aortic atresia is a rare diagnosis and its prognosis is very poor. In this article, we present a case of isolated aortic atresia, a very rare cardiovascular anomaly, and its fetal ultrasound findings which include blood flow at foramen ovale from left to right, right deviation of the interventricular septum, dysfunction of the mitral valve and cardiomegaly. Aortic stenosis should be considered in the differential diagnosis of aortic atresia. However, in the case of severe aortic stenosis and/or accompanying ventricular septal defect, differential diagnosis may not be done. PMID:24592058

  8. Percutaneous Transcatheter Aortic Disc Valve Prosthesis Implantation: A Feasibility Study

    SciTech Connect

    Sochman, Jan

    2000-09-15

    Purpose: Over the past 30 years there have been experimental efforts at catheter-based management of aortic valve regurgitation with the idea of extending treatment to nonsurgical candidates. A new catheter-based aortic valve design is described.Methods: The new catheter-delivered valve consists of a stent-based valve cage with locking mechanism and a prosthetic flexible tilting valve disc. The valve cage is delivered first followed by deployment and locking of the disc. In acute experiments, valve implantation was done in four dogs.Results: Valve implantation was successful in all four animals. The implanted valve functioned well for the duration of the experiments (up to 3 hr).Conclusion: The study showed the implantation feasibility and short-term function of the tested catheter-based aortic disc valve. Further experimental studies are warranted.

  9. Valve-in-valve transcatheter aortic valve implantation: the new playground for prosthesis-patient mismatch.

    PubMed

    Faerber, Gloria; Schleger, Simone; Diab, Mahmoud; Breuer, Martin; Figulla, Hans R; Eichinger, Walter B; Doenst, Torsten

    2014-06-01

    Transcatheter aortic valve implantation (TAVI) has become an established procedure for patients with aortic valve stenosis and significant comorbidities. One option offered by this technique is the implantation of a transcatheter valve inside a surgically implanted bioprosthesis. Many reports address the feasibility but also the pitfalls of these valve-in-valve (VIV) procedures. Review articles provide tables listing which valve sizes are appropriate based on the size of the initially implanted bioprosthesis. However, we previously argued that the hemodynamic performance of a prosthetic tissue valve is in large part a result of the dimensions of the bioprosthesis in relation to the patient's aortic outflow dimensions. Thus, the decision if a VIV TAVI procedure is likely to be associated with a favorable hemodynamic result cannot safely be made by looking at premade sizing tables that do not include patient dimensions and do not inquire about the primary cause for bioprosthetic valve stenosis. Prosthesis-patient mismatch (PPM) may therefore be more frequent than expected after conventional aortic valve replacement. Importantly, it may be masked by a potentially flawed method assessing its relevance. Such PPM may therefore impact significantly on hemodynamic outcome after VIV TAVI. Fifteen percent of currently published VIV procedures show only a minimal reduction of pressure gradients. We will address potential pitfalls in the current determination of PPM, outline the missing links for reliable determination of PPM, and present a simplified algorithm to guide decision making for VIV TAVI. PMID:24612128

  10. Echocardiographic detection of subvalvar aortic root aneurysm extending to mitral valve annulus as complication of aortic valve endocarditis.

    PubMed Central

    Griffiths, B E; Petch, M C; English, T A

    1982-01-01

    Acute aortic regurgitation as a consequence of infective endocarditis developed in a young man after peritonitis. A large subvalvar aortic root aneurysm extending to the mitral valve annulus together with features of severe acute aortic regurgitation were shown by M-mode echocardiography. The echocardiographic findings were confirmed at operation when obliteration of the aneurysmal space and aortic valve replacement were performed. Postoperative echocardiography confirmed obliteration of the aneurysmal space. Images PMID:6895998

  11. [Use of sutureless prosthetic aortic valves in cardiac surgery].

    PubMed

    Santarpino, Giuseppe; Fischlein, Theodor

    2014-03-01

    In the last years, an increasing proportion of high-risk patients undergo surgical aortic valve replacement. In order to reduce the risk associated with cross-clamp time or cardioplegic ischemic time, sutureless aortic prostheses have been developed. These bioprosthetic valves are not hand sewn, and this technological advance translates into reduced implantation times, thus improving outcome of patients referred for aortic valve replacement. At present, three sutureless bioprostheses are available on the market: 3f Enable (Medtronic Inc., Minneapolis, Minnesota, USA), Perceval (Sorin Group, Saluggia, Italy) and Intuity (Edwards Lifesciences, Irvine, California, USA). This article provides an overview of the available literature on sutureless aortic valves with the aim to better define current role and future perspectives of sutureless aortic bioprostheses for the treatment of aortic valve stenosis. PMID:24770430

  12. Transluminal aortic valve placement. A feasibility study with a newly designed collapsible aortic valve.

    PubMed

    Moazami, N; Bessler, M; Argenziano, M; Choudhri, A F; Cabreriza, S E; Allendorf, J D; Rose, E A; Oz, M C

    1996-01-01

    Percutaneous stents are used in vascular applications in conjunction with angioplasty and in combination with graft material for repair of abdominal aneurysms. The authors have designed a collapsible bioprosthetic aortic valve for placement by a transluminal catheter technique. This trileaflet stent valve is composed of stainless steel and bovine pericardium. Stent valves, 23 and 29 mm, were tested in a pulse duplicator system with rigid rings from 21 to 31 mm in 2 mm increments. At a mean flow of 3.1 L/min (+/-0.7), normal systemic aortic pressure was generated with a transvalvular gradient of 14.9 +/- 7 mmHg (mean +/- SD). Regurgitation fraction ranged from 10 to 18% (mean 13.8 +/- 3%) in the best ring size. Valves with the best hemodynamic profile were used for implantation in three 70 kg pigs in an open chest model. The valve was collapsed in a 24 Fr catheter designed to allow slow, controlled release. After resection of the native leaflets, the new valve was placed in the subcoronary position. No additional sutures were used for securing the valve. Two animals were successfully weaned from cardiopulmonary bypass and maintained systemic pressures of 100/45 (+/-10) and 116/70 (+/-15) mmHg, respectively. Intraoperative color echocardiography revealed minimal regurgitation, central flow, full apposition of all leaflets, and no interference with coronary blood flow. Both animals were sacrificed after being off bypass for 2 hr. Postmortem examination revealed the valves to be securely anchored. The third animal was weaned from cardiopulmonary bypass but developed refractory ventricular fibrillation because of valve dislodgment due to structural failure. Although long term survival data are needed, development of a hemodynamically acceptable prosthetic aortic valve for transluminal placement is feasible. PMID:8944912

  13. Mathematical modeling of aortic valve dynamics during systole.

    PubMed

    Aboelkassem, Yasser; Savic, Dragana; Campbell, Stuart G

    2015-01-21

    We have derived a mathematical model describing aortic valve dynamics and blood flow during systole. The model presents a realistic coupling between aortic valve dynamics, sinus vortex local pressure, and variations in the systemic vascular resistance. The coupling is introduced by using Hill׳s classical semi-spherical vortex model and an aortic pressure-area compliance constitutive relationship. The effects of introducing aortic sinus eddy vortices and variable systemic vascular resistance on overall valve opening-closing dynamics, left ventricular pressure, aortic pressure, blood flow rate, and aortic orifice area are examined. In addition, the strength of the sinus vortex is coupled explicitly to the valve opening angle, and implicitly to the aortic orifice area in order to predict how vortex strength varies during the four descriptive phases of aortic valve motion (fast-opening, fully-opening, slow-closing, and fast-closing). Our results compare favorably with experimental observations and the model reproduces well-known phenomena corresponding to aortic valve function such as the dicrotic notch and retrograde flow at end systole. By invoking a more complete set of physical phenomena, this new model will enable representation of pathophysiological conditions such as aortic valve stenosis or insufficiency, making it possible to predict their integrated effects on cardiac load and systemic hemodynamics. PMID:25451522

  14. AKI after Transcatheter or Surgical Aortic Valve Replacement.

    PubMed

    Thongprayoon, Charat; Cheungpasitporn, Wisit; Srivali, Narat; Harrison, Andrew M; Gunderson, Tina M; Kittanamongkolchai, Wonngarm; Greason, Kevin L; Kashani, Kianoush B

    2016-06-01

    Transcatheter aortic valve replacement (TAVR) is an alternative to surgical aortic valve replacement (SAVR) for patients with symptomatic severe aortic stenosis who are at high risk of perioperative mortality. Previous studies showed increased risk of postoperative AKI with TAVR, but it is unclear whether differences in patient risk profiles confounded the results. To conduct a propensity-matched study, we identified all adult patients undergoing isolated aortic valve replacement for aortic stenosis at Mayo Clinic Hospital in Rochester, Minnesota from January 1, 2008 to June 30, 2014. Using propensity score matching on the basis of clinical characteristics and preoperative variables, we compared the postoperative incidence of AKI, defined by Kidney Disease Improving Global Outcomes guidelines, and major adverse kidney events in patients treated with TAVR with that in patients treated with SAVR. Major adverse kidney events were the composite of in-hospital mortality, use of RRT, and persistent elevated serum creatinine ≥200% from baseline at hospital discharge. Of 1563 eligible patients, 195 matched pairs (390 patients) were created. In the matched cohort, baseline characteristics, including Society of Thoracic Surgeons risk score and eGFR, were comparable between the two groups. Furthermore, no significant differences existed between the TAVR and SAVR groups in postoperative AKI (24.1% versus 29.7%; P=0.21), major adverse kidney events (2.1% versus 1.5%; P=0.70), or mortality >6 months after surgery (6.0% versus 8.3%; P=0.51). Thus, TAVR did not affect postoperative AKI risk. Because it is less invasive than SAVR, TAVR may be preferred in high-risk individuals. PMID:26487562

  15. Molecular mechanisms underlying the onset of degenerative aortic valve disease.

    PubMed

    Hakuno, Daihiko; Kimura, Naritaka; Yoshioka, Masatoyo; Fukuda, Keiichi

    2009-01-01

    Morbidity from degenerative aortic valve disease is increasing worldwide, concomitant with the ageing of the general population and the habitual consumption of diets high in calories and cholesterol. Immunohistologic studies have suggested that the molecular mechanism occurring in the degenerate aortic valve resembles that of atherosclerosis, prompting the testing of HMG CoA reductase inhibitors (statins) for the prevention of progression of native and bioprosthetic aortic valve degeneration. However, the effects of these therapies remain controversial. Although the molecular mechanisms underlying the onset of aortic valve degeneration are largely unknown, research in this area is advancing rapidly. The signaling components involved in embryonic valvulogenesis, such as Wnt, TGF-beta(1), BMP, and Notch, are also involved in the onset of aortic valve degeneration. Furthermore, investigations into extracellular matrix remodeling, angiogenesis, and osteogenesis in the aortic valve have been reported. Having noted avascularity of normal cardiac valves, we recently identified chondromodulin-I (chm-I) as a crucial anti-angiogenic factor. The expression of chm-I is restricted to cardiac valves from late embryogenesis to adulthood in the mouse, rat, and human. In human degenerate atherosclerotic valves, the expression of vascular endothelial growth factor (VEGF) and matrix metalloproteinases and angiogenesis is observed in the area of chm-I downregulation. Gene targeting of chm-I resulted in VEGF expression, angiogenesis, and calcification in the aortic valves of aged mice, and aortic stenosis is detected by echocardiography, indicating that chm-I is a crucial factor for maintaining normal cardiac valvular function by preventing angiogenesis. The present review focuses on the animal models of aortic valve degeneration and recent studies on the molecular mechanisms underlying the onset of degenerative aortic valve disease. PMID:18766323

  16. Valve Replacement with a Sutureless Aortic Prosthesis in a Patient with Concomitant Mitral Valve Disease and Severe Aortic Root Calcification

    PubMed Central

    Scafuri, Antonio; Nicolò, Francesca; Chiariello, Luigi

    2016-01-01

    Aortic valve replacement with concomitant mitral valve surgery in the presence of severe aortic root calcification is technically difficult, with long cardiopulmonary bypass and aortic cross-clamp times. We performed sutureless aortic valve replacement and mitral valve annuloplasty in a 68-year-old man who had severe aortic stenosis and moderate-to-severe mitral regurgitation. Intraoperatively, we found severe calcification of the aortic root. We approached the aortic valve through a transverse aortotomy, performed in a higher position than usual, and we replaced the valve with a Sorin Perceval S sutureless prosthesis. In addition, we performed mitral annuloplasty with use of an open rigid ring. The aortic cross-clamp time was 63 minutes, and the cardiopulmonary bypass time was 83 minutes. No paravalvular leakage of the aortic prosthesis was detected 30 days postoperatively. Our case shows that the Perceval S sutureless bioprosthesis can be safely implanted in patients with aortic root calcification, even when mitral valve disease needs surgical correction. PMID:27127442

  17. Modified Lipoprotein-Derived Lipid Particles Accumulate in Human Stenotic Aortic Valves

    PubMed Central

    Lehti, Satu; Käkelä, Reijo; Hörkkö, Sohvi; Kummu, Outi; Helske-Suihko, Satu; Kupari, Markku; Werkkala, Kalervo; Kovanen, Petri T.; Öörni, Katariina

    2013-01-01

    In aortic stenosis plasma lipoprotein-derived lipids accumulate in aortic valves. Here, we first compared the lipid compositions of stenotic aortic valves and atherosclerotic plaque cores. Both pathological tissues were found to be enriched in cholesteryl linoleate, a marker of extracellularly accumulated lipoproteins. In addition, a large proportion of the phospholipids were found to contain arachidonic acid, the common precursor of a number of proinflammatory lipid mediators. Next, we isolated and characterized extracellular lipid particles from human stenotic and non-stenotic control valves, and compared them to plasma lipoproteins from the same subjects. The extracellular valvular lipid particles were isolated from 15 stenotic and 14 non-stenotic aortic valves. Significantly more apoB-100-containing lipid particles were found in the stenotic than in the non-stenotic valves. The majority of the lipid particles isolated from the non-stenotic valves had sizes (23±6.2 nm in diameter) similar to those of plasma low density lipoprotein (LDL) (22±1.5 nm), while the lipid particles from stenotic valves were not of uniform size, their sizes ranging from 18 to more than 500 nm. The lipid particles showed signs of oxidative modifications, and when compared to isolated plasma LDL particles, the lipid particles isolated from the stenotic valves had a higher sphingomyelin/phosphatidylcholine –ratio, and also higher contents of lysophosphatidylcholine and unesterified cholesterol. The findings of the present study reveal, for the first time, that in stenotic human aortic valves, infiltrated plasma lipoproteins have undergone oxidative and lipolytic modifications, and become fused and aggregated. The generated large lipid particles may contribute to the pathogenesis of human aortic stenosis. PMID:23762432

  18. Mechanics of the pulmonary valve in the aortic position.

    PubMed

    Soares, A L F; van Geemen, D; van den Bogaerdt, A J; Oomens, C W J; Bouten, C V C; Baaijens, F P T

    2014-01-01

    Mathematical models can provide valuable information to assess and evaluate the mechanical behavior and remodeling of native tissue. A relevant example when studying collagen remodeling is the Ross procedure because it involves placing the pulmonary autograft in the more demanding aortic valve mechanical environment. The objective of this study was therefore to assess and evaluate the mechanical differences between the aortic valve and pulmonary valve and the remodeling that may occur in the pulmonary valve when placed in the aortic position. The results from biaxial tensile tests of pairs of human aortic and pulmonary valves were compared and used to determine the parameters of a structurally based constitutive model. Finite element analyzes were then performed to simulate the mechanical response of both valves to the aortic diastolic load. Additionally, remodeling laws were applied to assess the remodeling of the pulmonary valve leaflet to the new environment. The pulmonary valve showed to be more extensible and less anisotropic than the aortic valve. When exposed to aortic pressure, the pulmonary leaflet appeared to remodel by increasing its thickness and reorganizing its collagen fibers, rotating them toward the circumferential direction. PMID:24035437

  19. Simulation for transthoracic echocardiography of aortic valve.

    PubMed

    Nanda, Navin C; Kapur, K K; Kapoor, Poonam Malhotra

    2016-01-01

    Simulation allows interactive transthoracic echocardiography (TTE) learning using a virtual three-dimensional model of the heart and may aid in the acquisition of the cognitive and technical skills needed to perform TTE. The ability to link probe manipulation, cardiac anatomy, and echocardiographic images using a simulator has been shown to be an effective model for training anesthesiology residents in transesophageal echocardiography. A proposed alternative to real-time reality patient-based learning is simulation-based training that allows anesthesiologists to learn complex concepts and procedures, especially for specific structures such as aortic valve. PMID:27397455

  20. Simulation for transthoracic echocardiography of aortic valve

    PubMed Central

    Nanda, Navin C.; Kapur, K. K.; Kapoor, Poonam Malhotra

    2016-01-01

    Simulation allows interactive transthoracic echocardiography (TTE) learning using a virtual three-dimensional model of the heart and may aid in the acquisition of the cognitive and technical skills needed to perform TTE. The ability to link probe manipulation, cardiac anatomy, and echocardiographic images using a simulator has been shown to be an effective model for training anesthesiology residents in transesophageal echocardiography. A proposed alternative to real-time reality patient-based learning is simulation-based training that allows anesthesiologists to learn complex concepts and procedures, especially for specific structures such as aortic valve. PMID:27397455

  1. Aortic valve surgery: what is the future?

    PubMed

    Hudorović, Narcis

    2008-04-01

    Modern surgical treatment for aortic valve disease has undergone significant improvements in all areas of this procedure. Successful treatment strategies for cardiovascular diseases have often been initiated and driven by surgeons. Radical excision of diseased tissue, repair and replacement strategies lead to long-term successful treatment of the underlying diseases and clearly improved patient outcome. In highly developed nations, valve surgery will be increasing applied in older people, with more co-morbidities and a higher incidence of concomitant coronary artery disease. Cardiovascular surgeons will be facing increased competition from the catheter-based procedures; these are already applied clinically, and their numbers will rise in near future. Right now interventional cardiologists supported by some cardiac surgeons are on their way to transform some conventional open surgical procedures into catheter-based less invasive interventions, such as valve repair and replacement. Cardiovascular surgery is undergoing a rapid transformation; socio-economic factors and recent advances in medical technology contribute to these changes. Further developments will come, and surgeons with all their expertise in the treatment of valvular heart disease need to be part of it. Cardiovascular surgeons have to adapt the exciting new approaches of transapical and transfemoral transcatheter valve implantation techniques. PMID:17573248

  2. Turbulence downstream of subcoronary stentless and stented aortic valves.

    PubMed

    Funder, Jonas Amstrup; Frost, Markus Winther; Wierup, Per; Klaaborg, Kaj-Erik; Hjortdal, Vibeke; Nygaard, Hans; Hasenkam, J Michael

    2011-08-11

    Regions of turbulence downstream of bioprosthetic heart valves may cause damage to blood components, vessel wall as well as to aortic valve leaflets. Stentless aortic heart valves are known to posses several hemodynamic benefits such as larger effective orifice areas, lower aortic transvalvular pressure difference and faster left ventricular mass regression compared with their stented counterpart. Whether this is reflected by diminished turbulence formation, remains to be shown. We implanted either stented pericardial valve prostheses (Mitroflow), stentless valve prostheses (Solo or Toronto SPV) in pigs or they preserved their native valves. Following surgery, blood velocity was measured in the cross sectional area downstream of the valves using 10MHz ultrasonic probes connected to a dedicated pulsed Doppler equipment. As a measure of turbulence, Reynolds normal stress (RNS) was calculated at two different blood pressures (baseline and 50% increase). We found no difference in maximum RNS measurements between any of the investigated valve groups. The native valve had significantly lower mean RNS values than the Mitroflow (p=0.004), Toronto SPV (p=0.008) and Solo valve (p=0.02). There were no statistically significant differences between the artificial valve groups (p=0.3). The mean RNS was significantly larger when increasing blood pressure (p=0.0006). We, thus, found no advantages for the stentless aortic valves compared with stented prosthesis in terms of lower maximum or mean RNS values. Native valves have a significantly lower mean RNS value than all investigated bioprostheses. PMID:21696741

  3. [Vasoplegic Syndrome after Aortic Valve Replacement].

    PubMed

    Miyata, Kazuto; Shigematsu, Sayaka

    2016-01-01

    We report a case of vasoplegic syndrome (VS) after aortic valve replacement in a 65 year old male with aortic stenosis. The patient developed hypotension after separation from cardiopulmonary bypass (CPB). Transesophageal echocardiography revealed well-maintained cardiac function and normal prosthetic valve function. However, his cardiac index was 3.0 l x min(-1) x m(-2) and systemic vascular resistance index (SVRI) was 1100 dynes x sec(-1) x cm(-5) x m(-2). Diagnosing VS, norepinephrine administration was commenced. Since his respiratory status was good, the patient was extubated on the day of surgery. Two days after surgery, catecholamines were discontinued with the stabilization of his circulatory status. However, his respiratory status showed gradual deterioration, and he was re-intubated. Chest X-ray showed bilateral pleural effusion, which was treated by drainage and fluid restriction. With this, his oxygenation improved and he could be extubated 5 days after surgery. Vasoplegic syndrome is a potentially life-threatening complication following cardiac surgery. Hypotension at the time of separation from CPB can be due to multiple factors. Despite an incidence rate of 10%, little is known about VS. We hope that, in future, tailored therapeutic protocols for VS will be developed. PMID:27004393

  4. Futility, Benefit, and Transcatheter Aortic Valve Replacement

    PubMed Central

    Lindman, Brian R.; Alexander, Karen P.; O'Gara, Patrick T.; Afilalo, Jonathan

    2015-01-01

    Transcatheter aortic valve replacement (TAVR) is a transformative innovation that provides treatment for high or prohibitive surgical risk patients with symptomatic severe aortic stenosis (AS) who were previously either not referred for or denied operative intervention. Trials have demonstrated improvements in survival and symptoms after TAVR compared to medical therapy, however there remains a sizable group of patients who die or lack improvement in quality of life soon after TAVR. This raises important questions about the need to identify and acknowledge the possibility of futility in some patients considered for TAVR. In this very elderly population, a number of factors in addition to traditional risk stratification need to be considered including multimorbidity, disability, frailty, and cognition in order to assess the anticipated benefit of TAVR. Consideration by a multidisciplinary heart valve team with broad areas of expertise is critical for assessing likely benefit from TAVR. Moreover, these complicated decisions should take place with clear communication around desired health outcomes on behalf of the patient and provider. The decision that treatment with TAVR is futile should include alternative plans to optimize the patient's health state or, in some cases, discussions related to end of life care. We review issues to be considered when making and communicating these difficult decisions. PMID:24954571

  5. Aortic valve patch closure: an alternative to replacement with HeartMate LVAS insertion.

    PubMed

    Savage, E B; d'Amato, T A; Magovern, J A

    1999-09-01

    A PTFE patch sewn to the aortic valve and annulus, to occlude the ventriculoaortic junction is used to successfully correct aortic insufficiency with HeartMate (LVAS) insertion. This represents an inexpensive alternative to aortic valve replacement for aortic insufficiency or the presence of a mechanical aortic valve. PMID:10554859

  6. Rapidly progressive aortic valve incompetence in a patient with rheumatoid arthritis.

    PubMed

    Camilleri, J P; Douglas-Jones, A G; Pritchard, M H

    1991-10-01

    A 27-year-old female with seropositive rheumatoid arthritis of onset at age 18 years developed progressive aortic valve incompetence requiring urgent aortic valve replacement. Rheumatoid aortic valve disease may be more rapidly progressive than aortic valve disease from other causes and awareness of this by the monitoring physicians may help to avoid the possible complications. PMID:1913010

  7. What is the best approach in a patient with a failed aortic bioprosthetic valve: transcatheter aortic valve replacement or redo aortic valve replacement?

    PubMed

    Tourmousoglou, Christos; Rao, Vivek; Lalos, Spiros; Dougenis, Dimitrios

    2015-06-01

    A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was whether transcatheter aortic valve-in-valve replacement (viv-TAVR) or redo aortic valve replacement (rAVR) is the best strategy in a patient with a degenerative bioprosthetic aortic valve. Altogether, 162 papers were found using the reported search, of which 12 represented the best evidence to answer the question. The authors, journal, date, country of publication, patient group, study type, outcomes and results of papers are tabulated. The results of the studies provided interesting results. All the studies are retrospective. Four papers reported the results of redo aortic valve replacement in patients with failed aortic bioprosthetic valve, six papers demonstrated their results with transcatheter aortic valve-in-valve replacement for the same indication and two papers reported their propensity-matched analysis of outcomes between viv-TAVR and rAVR in patients with previous cardiac surgery. Thirty-day mortality for rAVR was 2.3-15.5% and 0-17% for viv-TAVR. For rAVR, survival rate at 30 days was 83.6%, 76.1% at 1 year, 70.8% at 3 years, at 51.3-66% at 5 years, 61% at 8 years and 61.5% at 10 years. For viv-TAVR, the overall Kaplan-Meier survival rate at 1 year was 83.2%. After viv-TAVR at 1 year, 86.2% of surviving patients were at New York Heart Association (NYHA) class I/II. The complications after rAVR were stroke (4.6-5.8%), reoperation for bleeding (6.9-9.7%), low-cardiac output syndrome (9.9%) whereas complications after viv-TAVR at 30 days were major stroke (1.7%), aortic regurgitation of at least moderate degree (25%), new permanent pacemaker implantation rate (0-11%), ostial coronary obstruction (2%), need for implantation of a second device (5.7%) and major vascular complications (9.2%). It is noteworthy to mention that there is a valve-in-valve application that provides information to surgeons for choosing the correct size of the TAVR valve

  8. Reoperative Aortic Root Replacement in Patients with Previous Aortic Root or Aortic Valve Procedures

    PubMed Central

    Chong, Byung Kwon; Jung, Sung-Ho; Choo, Suk Jung; Chung, Cheol Hyun; Lee, Jae Won; Kim, Joon Bum

    2016-01-01

    Background Generalization of standardized surgical techniques to treat aortic valve (AV) and aortic root diseases has benefited large numbers of patients. As a consequence of the proliferation of patients receiving aortic root surgeries, surgeons are more frequently challenged by reoperative aortic root procedures. The aim of this study was to evaluate the outcomes of redo-aortic root replacement (ARR). Methods We retrospectively reviewed 66 patients (36 male; mean age, 44.5±9.5 years) who underwent redo-ARR following AV or aortic root procedures between April 1995 and June 2015. Results Emergency surgeries comprised 43.9% (n=29). Indications for the redo-ARR were aneurysm (n=12), pseudoaneurysm (n=1), or dissection (n=6) of the residual native aortic sinus in 19 patients (28.8%), native AV dysfunction in 8 patients (12.1%), structural dysfunction of an implanted bioprosthetic AV in 19 patients (28.8%), and infection of previously replaced AV or proximal aortic grafts in 30 patients (45.5%). There were 3 early deaths (4.5%). During follow-up (median, 54.65 months; quartile 1–3, 17.93 to 95.71 months), there were 14 late deaths (21.2%), and 9 valve-related complications including reoperation of the aortic root in 1 patient, infective endocarditis in 3 patients, and hemorrhagic events in 5 patients. Overall survival and event-free survival rates at 5 years were 81.5%±5.1% and 76.4%±5.4%, respectively. Conclusion Despite technical challenges and a high rate of emergency conditions in patients requiring redo-ARR, early and late outcomes were acceptable in these patients. PMID:27525233

  9. Infective Endocarditis of the Aortic Valve with Anterior Mitral Valve Leaflet Aneurysm

    PubMed Central

    Li, Wilson W.L.; van Paridon, Marieke; Bindraban, Navin R.; de Mol, Bas A.J.M.

    2016-01-01

    Mitral valve leaflet aneurysm is a rare and potentially devastating complication of aortic valve endocarditis. We report the case of a 48-year-old man who had endocarditis of the native aortic valve and a concomitant aneurysm of the anterior mitral valve leaflet. Severe mitral regurgitation occurred after the aneurysm perforated. The patient showed no signs of heart failure and completed a 6-week regimen of antibiotic therapy before undergoing successful aortic and mitral valve replacement. In addition to the patient's case, we review the relevant medical literature. PMID:27547149

  10. Infective Endocarditis of the Aortic Valve with Anterior Mitral Valve Leaflet Aneurysm.

    PubMed

    Tomsic, Anton; Li, Wilson W L; van Paridon, Marieke; Bindraban, Navin R; de Mol, Bas A J M

    2016-08-01

    Mitral valve leaflet aneurysm is a rare and potentially devastating complication of aortic valve endocarditis. We report the case of a 48-year-old man who had endocarditis of the native aortic valve and a concomitant aneurysm of the anterior mitral valve leaflet. Severe mitral regurgitation occurred after the aneurysm perforated. The patient showed no signs of heart failure and completed a 6-week regimen of antibiotic therapy before undergoing successful aortic and mitral valve replacement. In addition to the patient's case, we review the relevant medical literature. PMID:27547149

  11. Case report of Streptomyces endocarditis of a prosthetic aortic valve.

    PubMed Central

    Mossad, S B; Tomford, J W; Stewart, R; Ratliff, N B; Hall, G S

    1995-01-01

    We describe the first case of prosthetic valve endocarditis due to a Streptomyces sp. The patient presented with fever, cutaneous embolic lesions, and bacteremia 3 months after aortic valve replacement. Treatment required valve replacement and a long course of parenteral imipenem. PMID:8586732

  12. Balloon aortic valvuloplasty as a treatment option in the era of transcatheter aortic valve implantation.

    PubMed

    Costopoulos, Charis; Sutaria, Nilesh; Ariff, Ben; Fertleman, Michael; Malik, Iqbal; Mikhail, Ghada W

    2015-05-01

    Aortic valve stenosis is the commonest encountered valvular pathology and a frequent cause of morbidity and mortality in cases of severe stenosis. Definitive treatment has traditionally been offered in the form of surgical aortic valve replacement in patients with an acceptable surgical risk and more recently with the less invasive transcatheter aortic valve implantation (TAVI) in those where surgery is not a viable option. Prior to the introduction of TAVI, inoperable patients were treated medically and where appropriate with balloon aortic valvuloplasty, a procedure which although effective only provided short-term relief and was associated with high complication rates especially during its infancy. Here we discuss whether balloon aortic valvuloplasty continues to have a role in contemporary clinical practice in an era where significant advances have been achieved in the fields of surgical aortic valve replacement, TAVI and postoperative care. PMID:25865236

  13. [Unicuspid Aortic Valve Stenosis Combined with Aortic Coarctation;Report of a Case].

    PubMed

    Kubota, Takehiro; Wakasa, Satoru; Shingu, Yasushige; Matsui, Yoshiro

    2016-06-01

    Unicuspid aortic valve in an adult is extremely rare. In addition, 90% of the patients with aortic coarctation are reported to die before the age 50. A 60-year-old woman was admitted to our hospital for further examination of exertional dyspnea which had begun one year before. She had been under medical treatment for hypertension since early thirties, and had been also diagnosed with moderate aortic stenosis at 50 years of age. She was at 1st diagnosed with aortic coarctation combined with bicuspid aortic valve stenosis. The aortic valve was then found unicuspid and was replaced under cardiopulmonary bypass with perfusion to both the ascending aorta and the femoral artery. Repair of aortic coarctation was performed 3 months later through left thoracotomy without extracorporeal circulation due to the rich collateral circulation. She had no postoperative complications, and hypertension as well as ankle-brachial index improved to the normal levels. PMID:27246132

  14. Successful treatment of pure aortic insufficiency with transapical implantation of the JenaValve.

    PubMed

    Bleiziffer, Sabine; Mazzitelli, Domenico; Nöbauer, Christian; Ried, Thomas; Lange, Rüdiger

    2013-08-01

    Transcatheter aortic valve implantation was predominantly developed for patients with severe calcified aortic stenosis, as most devices are designed to anchor within the native valve calcium. We report on a patient with pure insufficiency of a non-calcified aortic valve, in whom an anatomically oriented catheter valve was implanted successfully. The design of the prosthesis with position feelers engaging the native aortic valve leaflets proved to be suitable for the treatment of pure aortic insufficiency. PMID:23344750

  15. Bilateral ostial coronary stenosis and rheumatic aortic valve stenosis.

    PubMed

    Sorokin, Alexeyi; Weich, Hellmuth; Doubell, Anton; Moolman, Johannes A

    2006-01-01

    A 49-year-old patient presented with angina pectoris and clinical findings of aortic valve stenosis and regurgitation. Rheumatic aortic valve stenosis and regurgitation was diagnosed on echocardiography. Coronary angiography findings showed severe calcification in the aorta root with right coronary ostial occlusion, and were suggestive of left main ostial stenosis and proximal main stem stenosis, which was confirmed on CT angiography. Curvilinear calcification of the aorta was present on CT angiography. The findings suggested syphilitic aortitis. Syphilis serology was positive (RPR titre 1/16). The angina was caused by severe coronary ostial disease likely due to syphilitic aortitis and exacerbated by the rheumatic aortic valve stenosis and regurgitation. PMID:16885079

  16. Aortic regurgitation caused by rupture of the abnormal fibrous band between the aortic valve and aortic wall.

    PubMed

    Minami, Hiroya; Asada, Tatsuro; Gan, Kunio; Yamada, Akitoshi; Sato, Masanobu

    2011-07-01

    This report documents the sudden onset of aortic regurgitation (AR) by an exceptional cause. A 68-year-old woman suddenly experienced general fatigue, and AR was diagnosed. One year later, we performed aortic valve replacement. At surgery, three aortic cusps with a larger noncoronary cusp had prolapsed along with a free-floating fibrous band that had previously anchored the cusp to the aortic wall. Its rupture had induced the sudden onset of AR. There was no sign of infectious endocarditis. We performed successful aortic valve replacement. PMID:21751110

  17. Functional annulus remodelling using a prosthetic ring in tricuspid aortic valve repair: mid-term results†

    PubMed Central

    Fattouch, Khalil; Castrovinci, Sebastiano; Murana, Giacomo; Nasso, Giuseppe; Guccione, Francesco; Dioguardi, Pietro; Salardino, Massimo; Bianco, Giuseppe; Speziale, Giuseppe

    2014-01-01

    OBJECTIVES The functional aortic valve annulus (FAVA) is a complex unit with proximal (aorto-ventricular junction) and distal (sinotubular junction) components. The aim of our study was to evaluate the impact of the total FAVA remodelling, using a prosthetic ring, on mid-term clinical and echocardiographic results after aortic valve repair. METHODS Since February 2003, 250 patients with tricuspid aortic valve insufficiency (AI) underwent aortic valve repair. FAVA dilatation was treated by prosthetic ring in 52 patients, by isolated subcommissural plasty in 62, by subcommissural plasty plus ascending aortic replacement in 57 and by David's reimplantation procedure in 79. Survival rate and freedom from recurrent AI greater than or equal to moderate were evaluated by Kaplan–Meier. RESULTS Overall late survival was 90.4%. Late cardiac-related deaths occurred in 15 patients. At follow-up, 36 (16%) patients had recurrent AI greater than or equal to moderate because of cusp reprolapse and/or FAVA redilatation. Freedom from recurrent AI was significantly higher for patients who underwent David's procedure or FAVA remodelling by prosthetic ring than those who underwent isolated subcommissural plasty (P < 0.01) or subcommissural plasty plus ascending aortic replacement (P = 0.02). There was no statistical difference between David's procedure and prosthetic ring annuloplasty (P = 0.26). CONCLUSION FAVA remodelling using a prosthetic ring is a safe procedure in aortic valve repair surgery thanks to long-term annulus stabilization and it is a pliable alternative to David's procedure in selected patients. This technique may be used in all patients with slight root dilatation to avoid aggressive root reimplantation. We also recommended total FAVA annuloplasty in all patients who underwent aortic valve repair to improve long-term repair results. PMID:24065345

  18. Bicuspid Aortic Stenosis Treated With the Repositionable and Retrievable Lotus Valve.

    PubMed

    Seeger, Julia; Gonska, Birgid; Rodewald, Christoph; Rottbauer, Wolfgang; Wöhrle, Jochen

    2016-01-01

    Transcatheter aortic valve implantation (TAVI) for severe aortic stenosis is a well-established and safe therapeutic option. However, data on TAVI in bicuspid aortic valve stenosis are limited and show a higher rate of moderate-severe aortic regurgitation compared with TAVI for tricuspid aortic valve stenosis. We report for the first time, to our knowledge, the use of the mechanically deployed Lotus valve in bicuspid aortic stenosis. In our patient who had severe bicuspid aortic stenosis and was at high surgical risk, the implantation of the repositionable and completely retrievable Lotus valve was a safe and controlled procedure resulting in no relevant aortic regurgitation. PMID:26604121

  19. New-onset atrial fibrillation after surgical aortic valve replacement and transcatheter aortic valve implantation: a concise review.

    PubMed

    Jørgensen, Troels Højsgaard; Thygesen, Julie Bjerre; Thyregod, Hans Gustav; Svendsen, Jesper Hastrup; Søndergaard, Lars

    2015-01-01

    Surgical aortic valve replacement (SAVR) and, more recently, transcatheter aortic valve implantation (TAVI) have been shown to be the only treatments that can improve the natural cause of severe aortic valve stenosis. However, after SAVR and TAVI, the incidence of new-onset atrial fibrillation (NOAF) is 31%-64% and 4%-32%, respectively. NOAF is independently associated with adverse events such as stroke, death, and increased length of hospital stay. Increasing the knowledge of predisposing factors, optimal postprocedural monitoring, and prophylactic antiarrhythmic and antithrombotic therapy may reduce the risk of complications secondary to NOAF. PMID:25589700

  20. Valve-in-Valve-in-Valve Transcatheter Aortic Valve Implantation to Treat a Degenerated Surgical Bioprosthesis in a Subaortic Position

    PubMed Central

    Nuis, Rutger-Jan; Benitez, Luis M.; Nader, Carlos A.; Perez, Sergio; de Marchena, Eduardo J.; Dager, Antonio E.

    2013-01-01

    Transcatheter aortic valve implantation for aortic stenosis has evolved as an alternative treatment for patients who are at high or excessive surgical risk. We report the case of an 84-year-old man with a degenerated surgically implanted valve in a subaortic position (9 mm below the native annulus) who underwent “valve-in-valve” transcatheter aortic valve implantation with use of a Medtronic CoreValve system. We planned to deploy the CoreValve at a conventional depth in the left ventricular outflow tract; we realized that this might result in paravalvular regurgitation, but it would also afford a “deep” landing site for a second valve, if necessary. Ultimately, we implanted a second CoreValve deep in the left ventricular outflow tract to seal a paravalvular leak. The frame of the first valve—positioned at the conventional depth—enabled secure anchoring of the second valve in a deeper position, which in turn effected successful treatment of the failing subaortic surgical prosthesis without paravalvular regurgitation. PMID:23914032

  1. Techniques of autologous pericardial leaflet replacement for aortic valve reconstruction.

    PubMed

    Rankin, J Scott; Nöbauer, Christian; Crooke, Philip S; Schreiber, Christian; Lange, Rüdiger; Mazzitelli, Domenico

    2014-08-01

    Glutaraldehyde-fixed autologous pericardium rarely calcifies or retracts, and it is a useful substitute for cardiac valve leaflets. Current understanding of aortic valve geometry provides good models for aortic leaflet design, and pericardial leaflet construction is illustrated in this article for bicuspid and tri-leaflet valves. Outcomes have been characterized by low valve-related complication rates, and results of recent series are encouraging. Perhaps sufficient data are available to consider autologous pericardial leaflet replacement in highly selected younger patients with irreparable leaflets and contraindications to warfarin. PMID:25087813

  2. [Reverse myocardial remodeling in patients with aortic valve disease and mitral insufficiency in early postoperative period].

    PubMed

    Belov, Iu V; Katkov, A I; Seslavinskaia, T V; Vinokurov, I A; Salagaev, G I

    2015-01-01

    Surgical treatment of patients with aortic valve disease and concomitant mitral insufficiency remains debatable. We analyzed early postoperative results of surgical treatment of 80 patients depending on type of surgery. All patients were divided into three groups: the 1st - aortic valve replacement in patients without mitral valve dysfunction (control group) (n=44); the 2nd - isolated aortic valve replacement in patients with concomitant mitral regurgitation degree 2-3 (n=18), the 3rd - simultaneous aortic and mitral valve replacement (n=18). Combined valve replacement was associated with more intraoperative blood loss (852.78±442.08 ml) compared with aortic valve replacement (658.7±374.09 ml), p<0.05. In patients with mitral regurgitation greater hematocrit decrease was observed (22.13±3.6% in group 2 and 21.4±4.48 in group 3) in comparison with control group (24.17±3.72% in group 1), p<0.05. Incidence of postoperative complications did not differ in all groups. Mortality rate was 6.8% in group 1 and 11.1% in group 3, there were no deaths in group 2. Both valves correction provided faster myocardial remodeling. Left ventricular end-diastolic volume decreased on 50 ml in group 3, on 33.67 ml in group 2 and on 50.73 ml in group 1 (p<0.05). Pulmonary pressure decreased on 20 mm Hg in group 3, on 13 mm Hg - in group 2 and on 12.57 mm Hg - in group 1, p<0.05. In groups 1 and 3 pulmonary pressure became normal after operation, in group 2 signs of pulmonary hypertension were observed (pressure - 35.3 mm Hg). Analysis of the results showed that simultaneous mitral and aortic valves replacement initiates normalization of intracardiac hemodynamics in early postoperative period. PMID:26081181

  3. Relapsing tricuspid valve endocarditis by multidrug-resistant Pseudomonas aeruginosa in 11 years: tricuspid valve replacement with an aortic valve homograft.

    PubMed

    Kim, Min-Seok; Chang, Hyoung Woo; Lee, Seung-Pyo; Kang, Dong Ki; Kim, Eui-Chong; Kim, Ki-Bong

    2015-01-01

    Eleven years ago, a 27-year-old non-drug abuser woman was admitted to the hospital due to a burn injury. During the treatment, she was diagnosed with tricuspid valve infective endocarditis caused by multi-drug resistant (MDR) Pseudomonas aeruginosa (P. aeruginosa). She underwent tricuspid valve replacement (TVR) using a bioprosthetic valve, followed by 6 weeks of meropenem antibiotic therapy. Ten years later, she was again diagnosed with prosthetic valve infective endocarditis caused by MDR P. aeruginosa. She underwent redo-TVR with a bioprosthetic valve and was treated with colistin and ciprofloxacin. Ten months later, she was again diagnosed with prosthetic valve infective endocarditis with MDR P. aeruginosa as a pathogen. She underwent a second redo-TVR with a tissue valve and was treated with colistin. Two months later, her fever recurred and she was again diagnosed with prosthetic valve infective endocarditis caused by MDR P. aeruginosa. She eventually underwent a third redo-TVR using an aortic valve homograft and was discharged from the hospital after additional 6 weeks' of antibiotic therapy. All the strains of P. aeruginosa isolated from each event of infective endocarditis were analyzed by repetitive deoxyribonucleic acid sequence-based polymerase chain reaction (rep-PCR) deoxyribonucleic acid (DNA) strain typing to determine the correlation of isolates. All of the pathogens in 11 years were similar enough to be classified as the same strain, and this is the first case report of TVR using an aortic valve homograft to treat relapsing endocarditis. PMID:26051245

  4. Pathological Investigation of Congenital Bicuspid Aortic Valve Stenosis, Compared with Atherosclerotic Tricuspid Aortic Valve Stenosis and Congenital Bicuspid Aortic Valve Regurgitation

    PubMed Central

    Hamatani, Yasuhiro; Ishibashi-Ueda, Hatsue; Nagai, Toshiyuki; Sugano, Yasuo; Kanzaki, Hideaki; Yasuda, Satoshi; Fujita, Tomoyuki; Kobayashi, Junjiro; Anzai, Toshihisa

    2016-01-01

    Background Congenital bicuspid aortic valve (CBAV) is the main cause of aortic stenosis (AS) in young adults. However, the histopathological features of AS in patients with CBAV have not been fully investigated. Methods and Results We examined specimens of aortic valve leaflets obtained from patients who had undergone aortic valve re/placement at our institution for severe AS with CBAV (n = 24, CBAV-AS group), severe AS with tricuspid aortic valve (n = 24, TAV-AS group), and severe aortic regurgitation (AR) with CBAV (n = 24, CBAV-AR group). We compared the histopathological features among the three groups. Pathological features were classified using semi-quantitative methods (graded on a scale 0 to 3) by experienced pathologists without knowledge of the patients’ backgrounds. The severity of inflammation, neovascularization, and calcium and cholesterol deposition did not differ between the CBAV-AS and TAV-AS groups, and these four parameters were less marked in the CBAV-AR group than in the CBAV-AS (all p<0.01). Meanwhile, the grade of valvular fibrosis was greater in the CBAV-AS group, compared with the TAV-AS and CBAV-AR groups (both p<0.01). In AS patients, thickness of fibrotic lesions was greater on the aortic side than on the ventricular side (both p<0.01). Meanwhile, thickness of fibrotic lesions was comparable between the aortic and ventricular sides in CBAV-AR patients (p = 0.35). Conclusions Valvular fibrosis, especially on the aortic side, was greater in patients with CBAV-AS than in those without, suggesting a difference in the pathogenesis of AS between CBAV and TAV. PMID:27479126

  5. Drivers of healthcare costs associated with the episode of care for surgical aortic valve replacement versus transcatheter aortic valve implantation

    PubMed Central

    Wijeysundera, Harindra C; Li, Lindsay; Braga, Vevien; Pazhaniappan, Nandhaa; Pardhan, Anar M; Lian, Dana; Leeksma, Aric; Peterson, Ben; Cohen, Eric A; Forsey, Anne; Kingsbury, Kori J

    2016-01-01

    Objective Transcatheter aortic valve implantation (TAVI) is generally more expensive than surgical aortic valve replacement (SAVR) due to the high cost of the device. Our objective was to understand the patient and procedural drivers of cumulative healthcare costs during the index hospitalisation for these procedures. Design All patients undergoing TAVI, isolated SAVR or combined SAVR+coronary artery bypass grafting (CABG) at 7 hospitals in Ontario, Canada were identified during the fiscal year 2012–2013. Data were obtained from a prospective registry. Cumulative healthcare costs during the episode of care were determined using microcosting. To identify drivers of healthcare costs, multivariable hierarchical generalised linear models with a logarithmic link and γ distribution were developed for TAVI, SAVR and SAVR+CABG separately. Results Our cohort consisted of 1310 patients with aortic stenosis, of whom 585 underwent isolated SAVR, 518 had SAVR+CABG and 207 underwent TAVI. The median costs for the index hospitalisation for isolated SAVR were $21 811 (IQR $18 148–$30 498), while those for SAVR+CABG were $27 256 (IQR $21 741–$39 000), compared with $42 742 (IQR $37 295–$56 196) for TAVI. For SAVR, the major patient-level drivers of costs were age >75 years, renal dysfunction and active endocarditis. For TAVI, chronic lung disease was a major patient-level driver. Procedural drivers of cost for TAVI included a non-transfemoral approach. A prolonged intensive care unit stay was associated with increased costs for all procedures. Conclusions We found wide variation in healthcare costs for SAVR compared with TAVI, with different patient-level drivers as well as potentially modifiable procedural factors. These highlight areas of further study to optimise healthcare delivery. PMID:27621832

  6. Percutaneous transluminal alcohol septal myocardial ablation after aortic valve replacement

    NASA Technical Reports Server (NTRS)

    Sitges, M.; Kapadia, S.; Rubin, D. N.; Thomas, J. D.; Tuzcu, M. E.; Lever, H. M.

    2001-01-01

    When left ventricular outflow tract obstruction develops after aortic valve replacement, few treatment choices have been available until now. We present a patient with prior aortic valve replacement who developed left ventricle outflow tract obstruction that was successfully treated with a percutaneous transcoronary myocardial septal alcohol ablation. This technique is a useful tool for the treatment of obstructive hypertrophic cardiomyopathy, especially in those patients with prior heart surgery. Copyright 2001 Wiley-Liss, Inc.

  7. "Killer coronary artery" and aortic valve stenosis: A tricky case.

    PubMed

    Nader, Joseph; Labont, Béatris Alina; Houpe, David; Caus, Thierry

    2015-11-01

    Anomalous origin of the left main coronary artery from the right coronary sinus is rarely diagnosed in elderly patients. We report such an anomaly in a 75-year-old lady presenting with chest pain and syncope. Preoperative screening revealed that her aortic valve was moderately stenotic. The patient underwent a successful unroofing procedure combined with aortic valve replacement. The outcome was uncomplicated and the patient remained asymptomatic at one year postoperatively. PMID:24787552

  8. CoreValve® transcatheter self-expandable aortic bioprosthesis.

    PubMed

    Bruschi, Giuseppe; De Marco, Federico; Martinelli, Luigi; Klugmann, Silvio

    2013-01-01

    Transcatheter aortic valve implantation has been designed to treat patients affected by severe symptomatic aortic stenosis considered extremely high risk for surgical aortic valve replacement. The CoreValve® (Medtronic Inc., MN, USA) is a multilevel self-expanding and fully radiopaque nitinol frame with a diamond cell configuration that holds a trileaflet porcine pericardial tissue valve and anchors the device in the native anatomy. CoreValve was the first percutaneous valve to be granted the CE mark for transfemoral implantation in May 2007 and the CoreValve US Pivotal Trial is actively underway. The CoreValve is available in four sizes (23, 26, 29 and 31 mm) to serve a broad range of patients' annulus from 18 to 29 mm. All the valves fit into an 18-Fr size catheter. Currently, more than 35,000 patients have been treated in more than 60 countries worldwide from the femoral artery, the axillary artery and, more recently, from a direct aortic approach, with excellent results up to 4-year follow-up. PMID:23278219

  9. [The research progress of transcatheter aortic valve replacement].

    PubMed

    Cheng, Maobo; Shi, Xinli; Jia, Jianxiong; Miao, Jingjing; Liu, Wei; Nie, Feilong

    2014-09-01

    During the past years transcatheter aortic valve replacement has evolved to a promising technique for the treatment of the patients who suffered from severe aortic stenosis, the progress and basic consideration on clinical study have been summarized in the article. PMID:25597083

  10. Shape-based diagnosis of the aortic valve

    NASA Astrophysics Data System (ADS)

    Ionasec, Razvan Ioan; Tsymbal, Alexey; Vitanovski, Dime; Georgescu, Bogdan; Zhou, S. Kevin; Navab, Nassir; Comaniciu, Dorin

    2009-02-01

    Disorders of the aortic valve represent a common cardiovascular disease and an important public-health problem worldwide. Pathological valves are currently determined from 2D images through elaborate qualitative evalu- ations and complex measurements, potentially inaccurate and tedious to acquire. This paper presents a novel diagnostic method, which identies diseased valves based on 3D geometrical models constructed from volumetric data. A parametric model, which includes relevant anatomic landmarks as well as the aortic root and lea ets, represents the morphology of the aortic valve. Recently developed robust segmentation methods are applied to estimate the patient specic model parameters from end-diastolic cardiac CT volumes. A discriminative distance function, learned from equivalence constraints in the product space of shape coordinates, determines the corresponding pathology class based on the shape information encoded by the model. Experiments on a heterogeneous set of 63 patients aected by various diseases demonstrated the performance of our method with 94% correctly classied valves.

  11. Transcatheter Aortic Valve Implantation in the Elderly: Who to Refer?

    PubMed Central

    Finn, Matthew; Green, Philip

    2015-01-01

    In recent years, experience with transcatheter aortic valve implantation has led to improved outcomes in elderly patients with severe aortic stenosis (AS) who may not have previously been considered for intervention. These patients are often frail with significant comorbid conditions. As the prevalence of AS increases, there is a need for improved assessment parameters to determine the patients most likely to benefit from this novel procedure. This review discusses the diagnostic criteria for severe AS and the trials available to aid in the decision to refer for aortic valve procedures in the elderly. PMID:25216621

  12. Recently patented transcatheter aortic valves in clinical trials.

    PubMed

    Neragi-Miandoab, Siyamek; Skripochnik, Edvard; Salemi, Arash; Girardi, Leonard

    2013-12-01

    The most widely used heart valve worldwide is the Edwards Sapien, which currently has 60% of the worldwide transcatheter aortic valve implantation (TAVI) market. The CoreValve is next in line in popularity, encompassing 35% of the worldwide TAVI market. Although these two valves dominate the TAVI market, a number of newer transcatheter valves have been introduced and others are in early clinical evaluation. The new valves are designed to reduce catheter delivery diameter, improve ease of positioning and sealing, and facilitate repositioning or removal. The most recent transcatheter valves for transapical use include Acurate TA (Symetis), Engager (Medtronic), and JenaValve the Portico (St Jude), Sadra Lotus Medical (Boston Scientific), and the Direct Flow Medical. These new inventions may introduce more effective treatment options for high-risk patients with severe aortic stenosis. Improvements in transcatheter valves and the developing variability among them may allow for more tailored approaches with respect to patient's anatomy, while giving operators the opportunity to choose devices they feel more comfortable with. Moreover, introducing new devices to the market will create a competitive environment among producers that will reduce high prices and expand availability. The present review article includes a discussion of recent patents related to Transcatheter Aortic Valves. PMID:24279506

  13. Simultaneous surgery of the aortic valve and sternal osteomyelitis.

    PubMed

    Urbanski, Paul P; Lindemann, Yvonne; Babin-Ebell, Jörg; Fröhner, Steffen; Diegeler, Anno

    2009-09-01

    A 64-year-old man was referred for aortic valve replacement due to severe stenosis. He also suffered chronic sternal osteomyelitis with skin fistula subsequent to radiation therapy. Both pathologies were approached simultaneously by sternal resection, omental plasty, and valve replacement, which led to favorable primary and mid-term result. PMID:19699936

  14. Relation of Aortic Valve Morphologic Characteristics to Aortic Valve Insufficiency and Residual Stenosis in Children With Congenital Aortic Stenosis Undergoing Balloon Valvuloplasty.

    PubMed

    Petit, Christopher J; Gao, Kevin; Goldstein, Bryan H; Lang, Sean M; Gillespie, Scott E; Kim, Sung-In H; Sachdeva, Ritu

    2016-03-15

    Aortic valve morphology has been invoked as intrinsic to outcomes of balloon aortic valvuloplasty (BAV) for congenital aortic valve stenosis. We sought to use aortic valve morphologic features to discriminate between valves that respond favorably or unfavorably to BAV, using aortic insufficiency (AI) as the primary outcome. All patients who underwent BAV at 2 large-volume pediatric centers from 2007 to 2014 were reviewed. Morphologic features assessed on pre-BAV echo included valve pattern (unicuspid, functional bicuspid, and true bicuspid), leaflet fusion length, leaflet excursion angle, and aortic valve opening area and on post-BAV echo included leaflet versus commissural tear. Primary end point was increase in AI (AI+) of ≥2°. Eighty-nine patients (median age 0.2 years) were included in the study (39 unicuspid, 41 functional bicuspid, and 9 true bicuspid valves). Unicuspid valves had a lower opening area (p <0.01) and greater fusion length (p = 0.01) compared with functional and true bicuspid valves. Valve gradient pre-BAV and post-BAV were not different among valve patterns. Of the 16 patients (18%) with AI+, 14 had leaflet tears (odds ratio 13.9, 3.8 to 50). True bicuspid valves had the highest rate (33%) of AI+. On multivariate analysis, leaflet tears were associated with AI+, with larger opening area pre-BAV and lower fusion length pre-BAV. AI+ was associated with larger pre-BAV opening area. Gradient relief was associated with reduced angle of excursion. Valve morphology influences outcomes after BAV. Valves with lesser fusion and larger valve openings have higher rates of leaflet tears which in turn are associated with AI. PMID:26805657

  15. Changing strategy for aortic stenosis with coronary artery disease by transcatheter aortic valve implantation.

    PubMed

    Kobayashi, Junjiro

    2013-12-01

    Coronary artery disease (CAD) is combined with aortic stenosis (AS) in 40-50 % of patients with typical angina. Recently, transcatheter aortic valve implantation (TAVI) has changed the guideline for AS in patients with high comorbidity. At the same time more than 60 % of isolated CABG has been performed without cardiopulmonary bypass in Japan. CABG is recommended and should be considered in patients with primary indication for AVR and luminal stenosis >70 % in major coronary arteries and the left internal thoracic artery (LITA) by guidelines. AVR is indicated for severe AS undergoing CABG. It is generally accepted to perform AVR for moderate AS at the time of CABG by valve guidelines. However, prophylactic AVR for moderate AS associated with CABG may increase the early operative risk and expose the patients to postoperative long-term valve related complications. AVR after previous CABG poses potential risk for mortality and morbidity. The presence of patent ITA is a significant risk of its injury and difficulty of myocardial protection during aortic cross-clamping. Therefore, at present, for severe AS previous CABG with patent ITA should be one of the definite indications of TAVI. Rationale of TAVI in patients with severe AS and CAD has not been clearly delineated. The safety of TAVI irrespective of the extent and anatomy of CAD is still controversial. PCI is not appropriate before TAVI in high-risk patients with CAD. In the near future hybrid TAVI will be realistic considering least operative mortality and morbidity in high-risk patients. PMID:23546769

  16. Intracardiac echocardiography to diagnose pannus formation after aortic valve replacement.

    PubMed

    Yamamoto, Yoshiya; Ohara, Takahiro; Funada, Akira; Takahama, Hiroyuki; Amaki, Makoto; Hasegawa, Takuya; Sugano, Yasuo; Kanzaki, Hideaki; Anzai, Toshihisa

    2016-03-01

    A 66-year-old female, under regular follow-up for 20 years after aortic valve replacement (19-mm Carbomedics), presented dyspnea on effort and hypotension during hemodialysis. A transthoracic echocardiogram showed elevation of transvalvular velocity up to 4 m/s, but the structure around the aortic prosthesis was difficult to observe due to artifacts. Fluoroscopy revealed normal motion of the leaflets of the mechanical valve. Intracardiac echocardiography (ICE) revealed a pannus-like structure in the left ventricular outflow tract. Transesophageal echocardiogram also revealed this structure. ICE can visualize structural abnormalities around a prosthetic valve after cardiac surgery even in patients in whom conventional imaging modalities failed. PMID:26732266

  17. Transcatheter Aortic and Mitral Valve Implantation (TAMVI) in Native Rheumatic Valves.

    PubMed

    Akujuo, Adanna C; Dellis, Sophia L; Britton, Lewis W; Bennett, Edward V

    2015-11-01

    A 68-year-old female with moderate to severe aortic stenosis and severe mitral stenosis, deemed too high risk for surgery (STS mortality risk = 12.3%) with a porcelain aorta, was successfully treated with a transcatheter aortic and mitral valve implantation (TAMVI) via a transapical approach. A 23 mm Sapien valve (Edwards Lifesciences, Irvine, CA, USA) was placed in the aortic position and a 29 mm inverted Sapien valve (Edwards Lifesciences) in the mitral position. PMID:26347492

  18. Delayed Chylous Pericardial Effusion after Aortic Valve Replacement

    PubMed Central

    Mundra, Vishal; Savage, Edward B.; Novaro, Gian M.; Asher, Craig R.

    2011-01-01

    Chylopericardium after cardiac surgery is rare, and there are few reports of its occurrence after aortic valve surgery. Chylous pericardial effusion 4 months after aortic valve replacement for endocarditis is highly unusual. Herein, we report the case of a 54-year-old man who had undergone bioprosthetic aortic valve replacement because of endocarditis and valvular dysfunction. Two months later, he underwent pericardiocentesis twice because of large pericardial effusions consisting of pinkish white fluid with predominant lymphocytes. Four months after valve replacement, he presented with recurrent effusion consistent with early tamponade, and a pericardial window was created. At surgery, 1,500 cc of milky white fluid was recovered, and the diagnosis of chylopericardium was made. Postoperative high-volume drainage prompted thoracic duct ligation, which was curative. PMID:21841877

  19. [Heart valves after 22 years - good long-term function of aortic homograft, advanced impairment in function of atrioventricular valves].

    PubMed

    Michalski, Błazej; Chrzanowski, Lukasz; Krzemińska-Pakula, Maria; Kasprzak, Jarosław D

    2010-03-01

    We report a case of a 61-year-old female patient with a history of aortic valve replacement, who was admitted to our hospital with symptoms and signs of decompensated heart failure (NYHA class III). Transthoracic echocardiogram revealed mitral valve and tricuspid valve regurgitation (III grade) with normal function of aortic valve homograft implanted 22 years ago. The patient underwent cardiosurgical mitral valve replacement and tricuspid valve annuloplasty with very good result. An aortic valve homograft may be the best alternative to a mechanical valves for a young female patients. PMID:20411462

  20. Impact of Pulmonary Hypertension on Outcomes Following Aortic Valve Replacement for Aortic Valve Stenosis

    PubMed Central

    Melby, Spencer J.; Moon, Marc R.; Lindman, Brian R.; Bailey, Marci S.; Hill, Laureen L.; Damiano, Ralph J.

    2011-01-01

    Objective The presence of pulmonary hypertension (PH) historically has been considered a significant risk factor affecting early and late outcomes following valve replacement. Given the number of recent advances in the management of PH following cardiac surgery a better understanding of the impact of PH on outcomes may assist in the clinical management of these patients. The purpose of this study was to determine if pulmonary hypertension remains a risk factor in the modern era for adverse outcomes following aortic valve replacement (AVR) for aortic valve stenosis. Methods From January 1996 to June 2009, 1,080 patients underwent AVR for primary aortic valve stenosis, of which 574 (53%) had normal systolic pulmonary artery pressures (sPAP) and 506 (47%) had PH. PH was defined as mild (sPAP 35-44 mmHg), moderate (45-59mmHg), or severe (≥ 60mmHg). In the group of patients with PH, 204 had postoperative echocardiograms. Results Operative mortality was significantly higher in patients with PH (47/506, 9% versus 31/574, 5%; p=0.02). The incidence of postoperative stroke was similar (p=0.14), but patients with PH had an increased median hospital LOS (8 versus 7 days, p=0.001) and an increased incidence of prolonged ventilation (26% versus 17%, p<0.001). Preoperative PH was an independent risk factor for decreased long term survival (RR 1.7, p=0.02). Those with persistent PH postoperatively had decreased survival. Five-year survival (Kaplan-Meier) was 78 ± 6% with normal sPAP and 77 ± 7% with mild PH postoperatively, compared to 64 ± 8% with moderate PH and 45 ± 12% with severe PH (p<0.001). Conclusion In patients undergoing AVR, preoperative PH increased operative mortality and decreased long-term survival. Patients with persistent moderate or severe PH after AVR had decreased long-term survival. These data suggest that PH had a significant impact on outcomes in patients undergoing AVR and should be considered in preoperative risk assessment. PMID:21596173

  1. Decision-making in aortic valve replacement: bileaflet mechanical valves versus stented bioprostheses

    PubMed Central

    Takkenberg, J.J.M.; Puvimanasinghe, J.P.A.; van Herwerden, L.A.; Eijkemans, M.J.C.; Steyerberg, E.W.; Habbema, J.D.F.; Bogers, A.J.J.C.

    2003-01-01

    Background Valve prosthesis selection for patients who require aortic valve replacement is dependent on several interrelated factors. Often, more than one valve type seems suitable for the individual patient and selection of a valve type may be difficult. Methods The application of an evidence-based microsimulation model as an objective tool to support the choice between a bileaflet mechanical prosthesis and a stented bioprosthesis in the individual patient is described. In addition, a pilot study investigating the effect of knowledge gained by this microsimulation model on prosthetic valve choice by cardiothoracic surgeons and cardiologists is presented for two hypothetical patients. Results After implantation of a mechanical valve, bleeding and thromboembolism are common, especially in the elderly. After implantation of a bioprosthesis, reoperation for structural failure is the most important valve-related complication, especially in younger patients. Life expectancy after aortic valve replacement is markedly reduced compared with the general Dutch age-matched population, regardless of the type of valve implanted. In the pilot study knowledge gained by the microsimulation model caused a shift in the preference towards a mechanical prosthesis in clinical experts. Conclusion Microsimulation incorporating current epidemiological data provides an objective tool to estimate prognosis for individual patients after aortic valve replacement with different valve prostheses. It may develop towards a useful clinical decision support system for valve prosthesis selection. ImagesFigure 6 PMID:25696138

  2. Left Main Coronary Artery Obstruction by Dislodged Native-Valve Calculus after Transcatheter Aortic Valve Replacement

    PubMed Central

    Durmaz, Tahir; Keles, Telat; Aslan, Abdullah Nabi; Erdogan, Kemal Esref; Sari, Cenk; Bilen, Emine; Akcay, Murat; Bozkurt, Engin

    2014-01-01

    Transcatheter aortic valve replacement can be an effective, reliable treatment for severe aortic stenosis in surgically high-risk or ineligible patients. However, various sequelae like coronary artery obstruction can occur, not only in the long term, but also immediately after the procedure. We present the case of a 78-year-old woman whose left main coronary artery became obstructed with calculus 2 hours after the transfemoral implantation of an Edwards Sapien XT aortic valve. Despite percutaneous coronary intervention in that artery, the patient died. This case reminds us that early recognition of acute coronary obstruction and prompt intervention are crucial in patients with aortic stenosis who have undergone transcatheter aortic valve replacement. PMID:25120396

  3. A planning system for transapical aortic valve implantation

    NASA Astrophysics Data System (ADS)

    Gessat, Michael; Merk, Denis R.; Falk, Volkmar; Walther, Thomas; Jacobs, Stefan; Nöttling, Alois; Burgert, Oliver

    2009-02-01

    Stenosis of the aortic valve is a common cardiac disease. It is usually corrected surgically by replacing the valve with a mechanical or biological prosthesis. Transapical aortic valve implantation is an experimental minimally invasive surgical technique that is applied to patients with high operative risk to avoid pulmonary arrest. A stented biological prosthesis is mounted on a catheter. Through small incisions in the fifth intercostal space and the apex of the heart, the catheter is positioned under flouroscopy in the aortic root. The stent is expanded and unfolds the valve which is thereby implanted into the aortic root. Exact targeting is crucial, since major complications can arise from a misplaced valve. Planning software for the perioperative use is presented that allows for selection of the best fitting implant and calculation of the safe target area for that implant. The software uses contrast enhanced perioperative DynaCT images acquired under rapid pacing. In a semiautomatic process, a surface segmentation of the aortic root is created. User selected anatomical landmarks are used to calculate the geometric constraints for the size and position of the implant. The software is integrated into a PACS network based on DICOM communication to query and receive the images and implants templates from a PACS server. The planning results can be exported to the same server and from there can be rertieved by an intraoperative catheter guidance device.

  4. Deformation of Congenital Bicuspid Aortic Valves in Systole

    NASA Astrophysics Data System (ADS)

    Szeto, Kai; Pastuszko, Peter; Nigam, Vishal; Lasheras, Juan

    2012-11-01

    Clinical studies have shown that patients with congenital bicuspid aortic valves (CBAVs) develop degenerative calcification of the leaflets at young ages compared to normal tricuspid aortic valves (TAVs). It has been hypothesized that the asymmetrical geometry of the leaflets in CBAVs and the associate changes in flow shear stresses and excessive strain rate levels are possible causes for the early calcification. Central to the validation of this hypothesis is the need to quantify the differences in strain rate levels between the BAVs and TAVs. We simulate the CBAVs by surgically stitching two of the leaflets of a porcine aortic valve together. To quantify strain differences, we performed in-vitro experiments in both BAVs and TAVs by tracking the 3-D motion of small dots marked on each leaflet surface. We then used phase-locked stereo photogrammetry to measure the strain rates in both radial and circumferential directions during the whole cardiac cycle. In the BAVs' case, the fused leaflet experiences an almost 30% increase in the radial stretching when fully open. RNA profiling of human aortic valve interstitial cells exposed to cyclic stretch shows that the increased stretch experienced by the BAVs results in increased levels of INTERLEUKINS (ILs) and other known inflammatory markers associated with aortic valve calcification. Together, these observations suggest that the abnormal stretch experienced by BAVs activates inflammation gene expression.

  5. Robotic System for Transapical Aortic Valve Replacement with MRI Guidance

    PubMed Central

    Li, Ming; Mazilu, Dumitru; Horvath, Keith A.

    2009-01-01

    This paper reports our work on developing a robotic surgical system for transapical beating heart aortic valve replacement (AVR) under interactive real-time magnetic resonance imaging (rtMRI) guidance. Our system integrates a real-time MRI system, a compound MRI robot, as well as an interface for the surgeon to plan the procedure and manipulate the robot. The compound robot consists of a positioning module and a valve delivery module. A 5-DOF Inno-motion positioning arm provides and maintains direct access to the native aortic valve. A newly developed 3-DOF robotic valve delivery module allows the surgeon to remotely control bioprosthetic valve delivery with MRI guidance. Preliminary evaluation of the parameters of the robotic system demonstrates it can provide sufficient capability to successfully assist the surgeon. PMID:18982639

  6. Complete Aortic Valve Cusp Replacement in the Pediatric Population Using Tissue-Engineered Bovine Pericardium.

    PubMed

    Mazzitelli, Domenico; Nöbauer, Christian; Rankin, J Scott; Vogt, Manfred; Lange, Rüdiger; Schreiber, Christian

    2015-11-01

    Three clinical cases of severe pediatric aortic valve defects undergoing complete aortic valve cusp replacement using tissue-engineered bovine pericardium are reported. All patients achieved excellent early results, and are being followed without complications. PMID:26522549

  7. Aortic Valve Reconstruction with Use of Pericardial Leaflets in Adults with Bicuspid Aortic Valve Disease: Early and Midterm Outcomes

    PubMed Central

    Song, Meong Gun; Yang, Hyun Suk; Shin, Je Kyoun; Chee, Hyun Keun; Kim, Jun Seok

    2014-01-01

    In this study, we retrospectively analyzed the outcomes of adults with bicuspid aortic valve (BAV) disease who underwent aortic valve reconstructive surgery (AVRS), consisting of replacement of the diseased BAV with 2 or 3 pericardial leaflets plus fixation of the sinotubular junction for accurate and constant leaflet coaptation. From December 2007 through April 2013, 135 consecutive patients (mean age, 49.2 ± 13.1 yr; 73.3% men) with symptomatic BAV disease underwent AVRS. Raphe was observed in 84 patients (62.2%), and the remaining 51 patients had pure BAV without raphe. A total of 122 patients (90.4%) underwent 3-leaflet reconstruction, and 13 (9.6%) underwent 2-leaflet reconstruction. Concomitant aortic wrapping with an artificial graft was performed in 63 patients (46.7%). There were no in-hospital deaths and 2 late deaths (1.5%); 6 patients (4.4%) needed valve-related reoperation. The 5-year cumulative survival rate was 98% ± 1.5%, and freedom from valve-related reoperation at 5 years was 92.7% ± 3.6%. In the last available echocardiograms, aortic regurgitation was absent or trivial in 116 patients (85.9%), mild in 16 (11.9%), moderate in 2 (1.5%), and severe in one (0.7%). The mean aortic valve gradient was 10.2 ± 4.5 mmHg, and the mean aortic valve orifice area index was 1.3 ± 0.3 cm2/m2. The 3-leaflet technique resulted in lower valve gradients and greater valve areas than did the 2-leaflet technique. Thus, in patients with BAV, AVRS yielded satisfactory early and midterm results with low mortality rates and low reoperation risk after the initial procedure. PMID:25593520

  8. Transcatheter Aortic Valve-in-Valve Replacement Instead of a 4th Sternotomy in a 21-Year-Old Woman with Aortic Homograft Failure

    PubMed Central

    Díez, José G.; Schechter, Michael; Dougherty, Kathryn G.; Preventza, Ourania

    2016-01-01

    Transcatheter aortic valve replacement (TAVR) is a well-established method for replacing native aortic valves; however, it was conceived for elderly patients with aortic valve stenosis, and the lack of data on long-term durability has led practitioners to restrict the use of TAVR to patients who have short life expectancies. Here, we describe the case of a 21-year-old woman who had undergone 3 previous open aortic valve replacements and who presented with symptoms of recurrent valvular failure. Transthoracic echocardiograms and computed tomographic angiograms revealed a degenerating aortic root homograft with substantial calcification, moderate-to-severe aortic valve stenosis, and severe aortic valve regurgitation. Open surgical valve replacement posed substantial risk to our patient, so we decided to perform valve-in-valve TAVR with use of the Edwards Sapien XT Transcatheter Heart Valve. The patient's pulmonary artery pressure, valvular regurgitation, and symptoms improved substantially thereafter. We found that valve-in-valve TAVR into a failing aortic root homograft was less invasive than repeat surgical valve replacement in this young patient who had congenital vascular anomalies and a complex surgical history. PMID:27547146

  9. Role of Echocardiography Before Transcatheter Aortic Valve Implantation (TAVI).

    PubMed

    Badiani, Sveeta; Bhattacharyya, Sanjeev; Lloyd, Guy

    2016-04-01

    Aortic stenosis (AS) is the most common primary valve disorder in the elderly with an increasing prevalence; transcatheter aortic valve implantation (TAVI) has become an accepted alternative to surgical aortic valve replacement (AVR) in the high risk or inoperable patient. Appropriate selection of patients for TAVI is crucial and requires a multidisciplinary approach including cardiothoracic surgeons, interventional cardiologists, anaesthetists, imaging experts and specialist nurses. Multimodality imaging including echocardiography, CT and MRI plays a pivotal role in the selection and planning process; however, echocardiography remains the primary imaging modality used for patient selection, intra-procedural guidance, post-procedural assessment and long-term follow-up. The contribution that contemporary transthoracic and transoesophageal echocardiography make to the selection and planning of TAVI is described in this article. PMID:26960423

  10. Transcatheter aortic valve implantation: from fantasy to reality

    PubMed Central

    2014-01-01

    Increased life expectancy has led to the presentation of more complicated patients in old age for the replacement of the aortic valve. The emergence of Transcatheter Aortic Valve Implantation (TAVI) was considered as a significant breakthrough in the management of symptomatic, moribund patients suffering from aortic valve stenosis who had been rejected for surgical intervention. A novel technology often has a long journey from the point at which it is created to its every-day-use. It is now obvious that TAVI practice in multiple institutes around the world has gone beyond the evidence. Serious concerns have been raised questioning the current TAVI practice. Analysis of future TAVI use may assist clinicians and healthcare managers to understand and deploy this technology in accordance with the evidence. PMID:24602509

  11. Minimally Invasive Cardiac Surgery: Transapical Aortic Valve Replacement

    PubMed Central

    Li, Ming; Mazilu, Dumitru; Horvath, Keith A.

    2012-01-01

    Minimally invasive cardiac surgery is less traumatic and therefore leads to quicker recovery. With the assistance of engineering technologies on devices, imaging, and robotics, in conjunction with surgical technique, minimally invasive cardiac surgery will improve clinical outcomes and expand the cohort of patients that can be treated. We used transapical aortic valve implantation as an example to demonstrate that minimally invasive cardiac surgery can be implemented with the integration of surgical techniques and engineering technologies. Feasibility studies and long-term evaluation results prove that transapical aortic valve implantation under MRI guidance is feasible and practical. We are investigating an MRI compatible robotic surgical system to further assist the surgeon to precisely deliver aortic valve prostheses via a transapical approach. Ex vivo experimentation results indicate that a robotic system can also be employed in in vivo models. PMID:23125924

  12. Transfemoral Aortic Valve Implantation with the New Edwards Sapien 3 Valve for Treatment of Severe Aortic Stenosis—Impact of Valve Size in a Single Center Experience

    PubMed Central

    Wöhrle, Jochen; Gonska, Birgid; Rodewald, Christoph; Seeger, Julia; Scharnbeck, Dominik; Rottbauer, Wolfgang

    2016-01-01

    Aims The third generation Edwards Sapien 3 (Edwards Lifesciences Inc., Irvine, California) system was optimized to reduce residual aortic regurgitation and vascular complications. Methods and Results 235 patients with severe symptomatic aortic stenosis were prospectively enrolled. Transcatheter aortic valve implantations (TAVI) were performed without general anesthesia by transfemoral approach. Patients were followed for 30 days. Patients received 23mm (N = 77), 26mm (N = 91) or 29mm (N = 67) valve based on pre-procedural 256 multislice computer tomography. Mean oversizing did not differ between the 3 valves. There was no residual moderate or severe aortic regurgitation. Rate of mild aortic regurgitation and regurgitation index did not differ between groups. There was no switch to general anesthesia or conversion to surgery. Rate of major vascular complication was 3.0% with no difference between valve and delivery sheath sizes. Within 30 days rates of all cause mortality (2.6%) and stroke (2.1%) were low. Conclusions In patients with severe aortic stenosis transfemoral TAVI with the Edwards Sapien 3 valve without general anesthesia was associated with a high rate of device success, no moderate or severe residual aortic regurgitation, low rates of major vascular complication, mortality and stroke within 30 days with no difference between the 3 valve sizes. Trial Registration ClinicalTrials.gov NCT02162069 PMID:27003573

  13. Hemolytic anemia with aortic stenosis resolved by urgent aortic valve replacement.

    PubMed

    Kawase, Isamu; Matsuo, Tatsuro; Sasayama, Koji; Suzuki, Hiroyuki; Nishikawa, Hideo

    2008-08-01

    A 78-year-old man with aortic stenosis complained of dark colored urine followed by recurrent chest pain and syncopal episodes. Echocardiography showed severely calcified aortic stenosis with the maximal pressure gradient of 125 mm Hg. Hemoglobin was 7.9 g/dL, lactate dehydrogenase was 2,295 IU/L, haptoglobin was less than 10 mg/dL, reticulocyte count was elevated, and Coombs' test was negative. We performed an urgent aortic valve replacement. After the surgery, the patient's urine became clear and his chest pain and syncope abated. All laboratory data returned to normal physiological values. In conclusion, the observed hemolysis was related to the aortic shear stress of a calcified aortic valve. PMID:18640351

  14. Pioneering transcatheter aortic valve Implant (Inovare®) via transfemoral.

    PubMed

    Pontes, José Carlos Dorsa Vieira; Duarte, João Jackson; Silva, Augusto Daige da; Dias, Amaury Mont'Serrat Ávila Souza; Benfatti, Ricardo Adala; Gardenal, Neimar; Benfatti, Amanda Ferreira Carli; Gomes, Jandir Ferreira

    2012-01-01

    We present a patient with severe aortic valvular bioprosthesis dysfunction implanted for 11 years, presenting with acute pulmonary edema due to severe valvular insufficiency with severe systolic dysfunction (EF <30%) and comorbid conditions that amounted operative risk (STS score > 10). We carried out the transcatheter aortic valve implantation (Inovare® - Braile Biomedica), which was implemented successfully by transfemoral access and good patient outcomes. PMID:23288191

  15. Transcatheter aortic valve implantation for failing surgical aortic bioprosthetic valve: from concept to clinical application and evaluation (part 1).

    PubMed

    Piazza, Nicolo; Bleiziffer, Sabine; Brockmann, Gernot; Hendrick, Ruge; Deutsch, Marcus-André; Opitz, Anke; Mazzitelli, Domenico; Tassani-Prell, Peter; Schreiber, Christian; Lange, Rüdiger

    2011-07-01

    With an aging population, improvement in life expectancy, and significant increase in the use of bioprosthetic valves, structural valve deterioration will become more and more prevalent. The operative mortality for an elective redo aortic valve surgery is reported to range from 2% to 7%, but this percentage can increase to more than 30% in high-risk and nonelective patients. Because transcatheter aortic valve (TAV)-in-surgical aortic valve (SAV) implantation represents a minimally invasive alternative to conventional redo surgery, it may prove to be safer and just as effective as redo surgery. Of course, prospective comparisons with a large number of patients and long-term follow-up are required to confirm these potential advantages. It is axiomatic that knowledge of the basic construction and dimensions, radiographic identification, and potential failure modes of SAV bioprostheses is fundamental in understanding key principles involved in TAV-in-SAV implantation. The goals of this paper are: 1) to review the classification, physical characteristics, and potential failure modes of surgical bioprosthetic aortic valves; and 2) to discuss patient selection and procedural techniques relevant to TAV-in-SAV implantation. PMID:21777879

  16. Recently patented and widely used valves for transcatheter aortic valve implantation.

    PubMed

    Neragi-Miandoab, Siyamek; Skripochnik, Edvard; Michler, Robert E

    2012-12-01

    Aortic stenosis (AS) is a serious condition in the aging US and European populations. Management of a stenotic valve is crucial as it can become symptomatic quickly leading to ventricular deterioration and overall poor quality of life. Considering that AS is a disease of the elderly patient population, surgical intervention may not be well tolerated by some patients. Transcatheter aortic valve implantation (TAVI) has emerged as an alternative approach for patients who are unsuitable surgical candidates. Since the first balloon-expandable Edwards SAPIEN valve (Edwards Lifesciences, Irvine, CA) was implanted by Dr. Cribier, many other valves have been introduced into clinical practice. Self-expanding valves such as the CoreValve ReValving system (Medtronic, Minneapolis, MN) for retrograde implantation and Symetis TX for antegrade and transapical implantation are the most frequently used self-expanding valves. The SAPIEN valve, on the other hand can be implanted both antegrade as well as retrograde. Overall, the most widely used valves are the Edwards SAPIEN and the CoreValve, which have been implanted in more than 40,000 patients worldwide. The Symetis valve has shown promising results in small series in Europe and may be introduced to the US market in the near future. This manuscript will review these 3 recently patented valves and discuss some of the clinical results that are available. PMID:23095028

  17. Bartonella henselae aortic valve endocarditis mimicking systemic vasculitis

    PubMed Central

    Teoh, Laurence S G; Hart, Hamish H; Soh, May Ching; Christiansen, Jonathan P; Bhally, Hasan; Philips, Martin S; Rai-Chaudhuri, Dominic S

    2010-01-01

    A 28-year-old man with a bicuspid aortic valve presented with facial droop and slurred speech with several months of constitutional symptoms of night sweats, weight loss and productive cough. Examination confirmed aortic regurgitation, palpable spleen and left facial droop. Multiple peripheral blood cultures were negative. Inflammatory markers, cytoplasmic staining antineutrophil cytoplasmic antibodies (cANCA) and anti-PR3 antibody were all elevated. MRI of the brain and CT of the chest and abdomen confirmed embolic infarcts to brain, kidney and spleen. Transoesophageal echocardiogram (ECG) showed valve vegetations and severe aortic regurgitation. Endocardial Wegener's granulomatosis was considered. Aortic valve replacement was performed. Grindings from aortic valve leaflets were analysed for rpoB gene, which confirmed the presence of Bartonella henselae. Serological assays demonstrated B henselae IgM 20 (normal <20) and IgG >2048 (normal < 64). The patient completely recovered after prolonged antibiotic treatment. Culture-negative infective endocarditis may mimic vasculitis and be associated with positive cANCA. Serology and molecular techniques may aid diagnosis. PMID:22791485

  18. Right infraaxillary thoracotomy for minimally invasive aortic valve replacement.

    PubMed

    Ito, Toshiaki; Maekawa, Atsuo; Hoshino, Satoshi; Hayashi, Yasunari

    2013-08-01

    Minimally invasive aortic valve replacement has been performed via partial sternotomy, the parasternal approach, and anterior intercostal approaches. We successfully performed aortic valve replacement through a small right infraaxillary thoracotomy in 25 patients, with the aid of a thoracoscope and a knot-pusher. The patients were 9 men and 16 women with a mean age of 72.6 years. Our approach had better cosmetic results than traditional approaches through the anterior chest wall. This method did not require rib transection or sacrifice of the internal thoracic artery. PMID:23910127

  19. Aortic valve endocarditis due to abiotrophia defectiva: a rare etiology.

    PubMed

    Yerebakan, Can; Westphal, Bernd; Skrabal, Christian; Kaminski, Alexander; Ugurlucan, Murat; Bomke, Anne-Kathrin; Liebold, Andreas; Steinhoff, Gustav

    2008-01-01

    Abiotrophia defectiva is a rare cause of infective endocarditis. Besides an association with often negative blood cultures and difficult treatment, high rates of relapse and higher mortality than endocarditis caused by other viridans streptococci are known features of this entity. We report on the surgical and medical management of the aortic valve endocarditis caused by Abiotrophia defectiva in a 19-year-old patient. To the best of our knowledge, this is the first case of a patient to have Down syndrome and Abiotrophia defectiva endocarditis requiring aortic valve replacement. PMID:18421556

  20. Posttranscatheter Aortic Valve Replacement Ventricular Septal Defect During Transfemoral Edwards SAPIEN Valve Implantation.

    PubMed

    Dahl, Aaron; Hoaglan, Carli; Helman, James

    2016-06-01

    Transcatheter aortic valve replacement (TAVR) is gaining favor as a treatment for aortic stenosis in patients at high risk for the open surgical approach. The following is a report of a 95-year-old woman with severe aortic stenosis who presented for TAVR with an Edwards SAPIEN valve. Her medical history included pacemaker-dependent complete heart block and a recent episode of congestive heart failure secondary to a non-ST segment elevation myocardial infarction. The TAVR was performed successfully through an open left femoral artery approach, and the patient was found to have a new perimembranous ventricular septal defect identified postoperatively. PMID:27243581

  1. Calcific Aortic Valve Disease: Molecular Mechanisms and Therapeutic Approaches

    PubMed Central

    Lerman, Daniel Alejandro; Prasad, Sai; Alotti, Nasri

    2016-01-01

    Calcification occurs in atherosclerotic vascular lesions and In the aortic valve. Calcific aortic valve disease (CAVD) is a slow, progressive disorder that ranges from mild valve thickening without obstruction of blood flow, termed aortic sclerosis, to severe calcification with impaired leaflet motion, termed aortic stenosis. In the past, this process was thought to be ‘degenerative’ because of time-dependent wear and tear of the leaflets, with passive calcium deposition. The presence of osteoblasts in atherosclerotic vascular lesions and in CAVD implies that calcification is an active, regulated process akin to atherosclerosis, with lipoprotein deposition and chronic inflammation. If calcification is active, via pro-osteogenic pathways, one might expect that development and progression of calcification could be inhibited. The overlap in the clinical factors associated with calcific valve disease and atherosclerosis provides further support for a shared disease mechanism. In our recent research we used an in vitro porcine valve interstitial cell model to study spontaneous calcification and potential promoters and inhibitors. Using this model, we found that denosumab, a human monoclonal antibody targeting the receptor activator of nuclear factor-κB ligand may, at a working concentration of 50 μg/mL, inhibit induced calcium deposition to basal levels.

  2. Left main coronary artery occlusion after percutaneous aortic valve implantation.

    PubMed

    Bartorelli, Antonio L; Andreini, Daniele; Sisillo, Erminio; Tamborini, Gloria; Fusari, Melissa; Biglioli, Paolo

    2010-03-01

    Left main coronary artery occlusion occurred immediately after transfemoral aortic valve implantation in an 87-year-old woman, which resulted in ventricular fibrillation and hemodynamic collapse. This life-threatening complication was promptly diagnosed with transesophageal echocardiography, which showed the disappearance of diastolic left main coronary artery jet flow and was confirmed with aortic root angiography. After prompt defibrillation, hemodynamic support was obtained with intra-aortic balloon pump and inotropic drugs. Functional recovery and survival were achieved with coronary stenting. This report highlights the importance of an integrated team approach of highly skilled specialists for these novel interventions. PMID:20172163

  3. Perceval S aortic valve implantation in an achondroplastic Dwarf.

    PubMed

    Baikoussis, Nikolaos G; Argiriou, Michalis; Argiriou, Orestis; Dedeilias, Panagiotis

    2016-01-01

    Despite cardiovascular disease in patients with dwarfism is not rare; there is a lack of reports referring to cardiac interventions in such patients. Dwarfism may be due to achondroplasia or hormonal growth disorders. We present a 58-year-old woman with episodes of dyspnea for several months. She underwent on transthoracic echocardiography, and she diagnosed with severe aortic valve stenosis. She referred to our department for surgical treatment of this finding. In accordance of her anthropometric characteristics and her very small aortic annulus, we had the dilemma of prosthesis selection. We decided to implant a stentless valve to optimize her effective orifice area. Our aim is to present the successful Perceval S valve implantation and the descriptions of the problems coming across in operating on these special patients. To our knowledge, this is the first case patient in which a Perceval S valve is implanted according to the international bibliography. PMID:26750695

  4. Uncommon acquired Gerbode defect following extensive bicuspid aortic valve endocarditis

    PubMed Central

    2012-01-01

    Gerbode defect is a rare type of left ventricle to right atrium shunt. It is usually congenital in origin, but acquired cases are also described, mainly following infective endocarditis, valve replacement, trauma or acute myocardial infarction. We report a case of a 50-year-old man who suffered an extensive and complex infective endocarditis involving a bicuspid aortic valve, the mitral-aortic intervalvular fibrosa and the anterior leaflet of the mitral valve. After dual valve replacement and annular reconstruction, a shunt between the left ventricle and the right atrium - Gerbode defect, and a severe leak of the mitral prosthesis were detected. Reintervention was performed with successful shunt closure with an autologous pericardial patch and paravalvular leak correction. No major complications occurred denying the immediate post-surgery period and the follow-up at the first year was uneventful. PMID:22360824

  5. Perceval S aortic valve implantation in an achondroplastic Dwarf

    PubMed Central

    Baikoussis, Nikolaos G.; Argiriou, Michalis; Argiriou, Orestis; Dedeilias, Panagiotis

    2016-01-01

    Despite cardiovascular disease in patients with dwarfism is not rare; there is a lack of reports referring to cardiac interventions in such patients. Dwarfism may be due to achondroplasia or hormonal growth disorders. We present a 58-year-old woman with episodes of dyspnea for several months. She underwent on transthoracic echocardiography, and she diagnosed with severe aortic valve stenosis. She referred to our department for surgical treatment of this finding. In accordance of her anthropometric characteristics and her very small aortic annulus, we had the dilemma of prosthesis selection. We decided to implant a stentless valve to optimize her effective orifice area. Our aim is to present the successful Perceval S valve implantation and the descriptions of the problems coming across in operating on these special patients. To our knowledge, this is the first case patient in which a Perceval S valve is implanted according to the international bibliography. PMID:26750695

  6. Replacement of a Dislocated Aortic Prosthesis After Transcatheter Valve Implantation.

    PubMed

    Mandegar, Mohammad Hossein; Moradi, Bahieh; Roshanali, Farideh

    2016-06-01

    A 77-year-old woman who had severe symptomatic aortic stenosis and was a high risk for conventional surgery underwent transcatheter aortic valve implantation by means of the transfemoral approach. The prosthesis migrated and became embolized in the left ventricle after inflation, causing interference with the mitral valve and also partial outflow tract obstruction. The patient was emergently transferred to the operating room. Vertical aortotomy was performed under cardiopulmonary bypass, and the calcified native leaflets were removed. The migrated Edwards SAPIEN XT valve was extracted and subsequently successfully sewn into the annulus after examination for leaflet and stent competence. The hemodynamic performance of the implanted valve was surprisingly more favorable than that of the conventional tissue prosthesis. PMID:27211978

  7. Lactococcus garvieae Endocarditis on a Prosthetic Biological Aortic Valve.

    PubMed

    Tsur, A; Slutzki, T; Flusser, D

    2015-09-01

    Lactococcus garvieae (LG) endocarditis is a rare disease in humans. There are only about 16 reported cases in the world. We report a 76-year-old male patient with LG endocarditis. In depth interview with the patient revealed that 2 weeks prior to admission, he had eaten sushi containing raw fish. Unlike many of the other infections reported, which were on a native mitral valve, our patient's vegetation was on a prosthetic aortic valve. PMID:25295408

  8. Biomechanical factors in the biology of aortic wall and aortic valve diseases

    PubMed Central

    Bäck, Magnus; Gasser, T. Christian; Michel, Jean-Baptiste; Caligiuri, Giuseppina

    2013-01-01

    The biomechanical factors that result from the haemodynamic load on the cardiovascular system are a common denominator of several vascular pathologies. Thickening and calcification of the aortic valve will lead to reduced opening and the development of left ventricular outflow obstruction, referred to as aortic valve stenosis. The most common pathology of the aorta is the formation of an aneurysm, morphologically defined as a progressive dilatation of a vessel segment by more than 50% of its normal diameter. The aortic valve is exposed to both haemodynamic forces and structural leaflet deformation as it opens and closes with each heartbeat to assure unidirectional flow from the left ventricle to the aorta. The arterial pressure is translated into tension-dominated mechanical wall stress in the aorta. In addition, stress and strain are related through the aortic stiffness. Furthermore, blood flow over the valvular and vascular endothelial layer induces wall shear stress. Several pathophysiological processes of aortic valve stenosis and aortic aneurysms, such as macromolecule transport, gene expression alterations, cell death pathways, calcification, inflammation, and neoangiogenesis directly depend on biomechanical factors. PMID:23459103

  9. Coronary artery dissection with rupture of aortic valve commissure following type A aortic dissection: the role of 64-slice MDCT.

    PubMed

    Das, K M; Abdou, Sayed M; El-Menyar, Ayman; Ayman, El Menyar; Khulaifi, A A; Nabti, A L

    2008-01-01

    A rare case of bilateral coronary artery dissection with rupture of aortic valve commissure following type A aortic dissection is described. 64-slice multidetector computed tomography (MDCT) was able to demonstrate both this findings along with involvement of other neck vessels. TEE demonstrated the severity and mechanisms of aortic valve damage and assisted the surgeon in valve repair. MDCT has played an invaluable role in the diagnosis of the abnormal details of such life-threatening vascular complications. PMID:18384568

  10. Salvage Extracorporeal Membrane Oxygenation Prior to "Bridge" Transcatheter Aortic Valve Replacement.

    PubMed

    Chiu, Peter; Fearon, William F; Raleigh, Lindsay A; Burdon, Grayson; Rao, Vidya; Boyd, Jack H; Yeung, Alan C; Miller, David Craig; Fischbein, Michael P

    2016-06-01

    We describe a patient who presented in profound cardiogenic shock due to bioprosthetic aortic valve stenosis requiring salvage Extracorporeal Membrane Oxygenation followed by a "bridge" valve-in-valve transcatheter aortic valve replacement. doi: 10.1111/jocs.12750 (J Card Surg 2016;31:403-405). PMID:27109017

  11. [Pannus Formation Two Years after Bioprosthetic Aortic Valve Implantation;Report of a Case].

    PubMed

    Ono, Kimiyo; Kuroda, Hiroaki

    2015-08-01

    We report a case of early deterioration of the bioprosthetic aortic valve 23 months postoperatively. A 77-year-old man who had undergone aortic valve replacement with a 23-mm Epic valve( St. Jude Medical [SJM])presented to us after a syncopal episode. Echocardiography revealed severe aortic stenosis, and redo aortic valve replacement with a 21-mm SJM mechanical valve was performed. All 3 cusps of the tissue valve were thickened by fibrous pannus overgrowth. Neither calcification nor invasion of inflammatory cells was observed. The cause of pannus formation at such an early stage after implantation remains unknown. PMID:26329714

  12. [Transcatheter Aortic Valve Implantation: An Introduction and Patient Care].

    PubMed

    Lu, Shu-Ju; Wang, Shiao-Pei

    2015-06-01

    Aortic stenosis has a high prevalence among individuals over 75 years of age. Transcatheter aortic valve implantation (TAVI) is a novel valve-replacement technique for patients with multiple chronic diseases who are at high risk of requiring aortic valve replacement surgery. Most of the time, the indicators of TAVI are detected during an echocardiographic exam. The femoral artery is the primary insertion site. The complications of TAVI include stroke, vascular dissection, bleeding, aortic valve regurgitation, and arrhythmia. In terms of clinical effectiveness, the mortality rate of TAVI is lower than percutaneous ballon valvuloplasty but similar to AVR. The unplanned cardiac-related re-admission rate within 30 days of discharge is lower for TAVI than for AVR. In terms of activity tolerance, TAVI is significantly better than both percutaneous ballon valvuloplasty and AVR. Comprehensive nursing care may reduce the incidence of complications associated with TAVI. Nursing care of TAVI includes explaining and providing instructions regarding TAVI prior to the procedure. After the TAVI procedure and while the patient is in the ICU, remove the endotracheal tube as soon as possible, monitor his / her neuro-cognitive status, monitor for early detection of a stroke event, record urine output to assess renal function, observe bleeding in the puncture site, and evaluate cardiac arrhythmia and pain. While in the general ward, resume early physical activities and educate the patient regarding the risks and the prevention of bleeding. This article provides references for clinical staff responsible to care for post-TAVI surgery patients. PMID:26073960

  13. Bicuspid aortic valve hemodynamics: a fluid-structure interaction study

    NASA Astrophysics Data System (ADS)

    Chandra, Santanu; Seaman, Clara; Sucosky, Philippe

    2011-11-01

    The bicuspid aortic valve (BAV) is a congenital defect in which the aortic valve forms with two leaflets instead of three. While calcific aortic valve disease (CAVD) also develops in the normal tricuspid aortic valve (TAV), its progression in the BAV is more rapid. Although studies have suggested a mechano-potential root for the disease, the native BAV hemodynamics remains largely unknown. This study aimed at characterizing BAV hemodynamics and quantifying the degree of wall-shear stress (WSS) abnormality on BAV leaflets. Fluid-structure interaction models validated with particle-image velocimetry were designed to predict the flow and leaflet dynamics in idealized TAV and BAV anatomies. Valvular function was quantified in terms of the effective orifice area. The regional leaflet WSS was characterized in terms of oscillatory shear index, temporal shear magnitude and temporal shear gradient. The predictions indicate the intrinsic degree of stenosis of the BAV anatomy, reveal drastic differences in shear stress magnitude and pulsatility on BAV and TAV leaflets and confirm the side- and site-specificity of the leaflet WSS. Given the ability of abnormal fluid shear stress to trigger valvular inflammation, these results support the existence of a mechano-etiology of CAVD in the BAV.

  14. Transcatheter aortic valve implantation: past, present and future.

    PubMed

    Keshavarzi, Freidoon; MacCarthy, Philip

    2016-03-01

    Transcatheter aortic valve implantation is one of the most significant technological advances in cardiovascular medicine. It offers a safe alternative in high risk cardiac patients with proven durability, economical viability and survival advantage. Current trials may expand its application in intermediate or low risk groups. PMID:26961440

  15. Quadricuspid aortic valves in Syrian hamsters and their formation according to current knowledge on valvulogenesis.

    PubMed

    López-García, Alejandro; Carmen Fernández, M; Durán, Ana Carmen; Sans-Coma, Valentín; Fernández, Borja

    2015-02-01

    Occurrence of quadricuspid aortic valves has been reported in humans, in nine dogs and in a greater white-toothed shrew. Moreover, two cases of developing aortic valves with four anticipated leaflets have been described in Syrian hamster embryos. Currently, however, no case of quadricuspid aortic valve in adult hamsters has been recorded. The aim here is to present four adults of this rodent species, two of them with unequivocally quadricuspid aortic valves and the other two with quadricuspid-like aortic valves. The four anomalous aortic valves were detected among 4,190 Syrian hamsters examined in our laboratory, representing an incidence of 0.09%. None of the affected hamsters showed apparent signs of disease. The present findings are considered on the light of current empirical knowledge about the morphogenesis of quadricuspid and bicuspid aortic and pulmonary valves. Quadricuspid aortic valves result from the partition of one of the normal mesenchymal cushions which normally give rise to normal (tricuspid) valves, while quadricuspid-like valves might be the product of a combined mechanism of fusion and partition of the cushions at the onset of the valvulogenesis. The presence of aortic valves with four leaflets in ancient mammalian lineages such as insectivors and rodents suggest that quadricuspid aortic valves, although showing almost certainly a low incidence, may be widespread among the different groups of mammals, including domestic animals. PMID:25854086

  16. Transcatheter Aortic Valve Replacement: a Kidney’s Perspective

    PubMed Central

    Cheungpasitporn, Wisit; Thongprayoon, Charat; Kashani, Kianoush

    2016-01-01

    Transcatheter aortic valve replacement (TAVR) has now emerged as a viable treatment option for high-risk patients with severe aortic stenosis (AS) who are not suitable candidates for surgical aortic valve replacement (SAVR). Despite encouraging published outcomes, acute kidney injury (AKI) is common and lowers the survival of patients after TAVR. The pathogenesis of AKI after TAVR is multifactorial including TAVR specific factors such as the use of contrast agents, hypotension during rapid pacing, and embolization; preventive measures may include pre-procedural hydration, limitation of contrast dye exposure, and avoidance of intraprocedural hypotension. In recent years, the number of TAVR performed worldwide has been increasing, as well as published data on renal perspectives of TAVR including AKI, chronic kidney disease, end-stage kidney disease, and kidney transplantation. This review aims to present the current literature on the nephrology aspects of TAVR, ultimately to improve the patients’ quality of care and outcomes. PMID:27069960

  17. COX2 Inhibition Reduces Aortic Valve Calcification In Vivo

    PubMed Central

    Wirrig, Elaine E.; Gomez, M. Victoria; Hinton, Robert B.; Yutzey, Katherine E.

    2016-01-01

    Objective Calcific aortic valve disease (CAVD) is a significant cause of morbidity and mortality, which affects approximately 1% of the US population and is characterized by calcific nodule formation and stenosis of the valve. Klotho-deficient mice were used to study the molecular mechanisms of CAVD as they develop robust aortic valve (AoV) calcification. Through microarray analysis of AoV tissues from klotho-deficient and wild type mice, increased expression of the gene encoding cyclooxygenase 2/COX2 (Ptgs2) was found. COX2 activity contributes to bone differentiation and homeostasis, thus the contribution of COX2 activity to AoV calcification was assessed. Approach and Results In klotho-deficient mice, COX2 expression is increased throughout regions of valve calcification and is induced in the valvular interstitial cells (VICs) prior to calcification formation. Similarly, COX2 expression is increased in human diseased AoVs. Treatment of cultured porcine aortic VICs with osteogenic media induces bone marker gene expression and calcification in vitro, which is blocked by inhibition of COX2 activity. In vivo, genetic loss of function of COX2 cyclooxygenase activity partially rescues AoV calcification in klotho-deficient mice. Moreover, pharmacologic inhibition of COX2 activity in klotho-deficient mice via celecoxib-containing diet reduces AoV calcification and blocks osteogenic gene expression. Conclusions COX2 expression is upregulated in CAVD and its activity contributes to osteogenic gene induction and valve calcification in vitro and in vivo. PMID:25722432

  18. Successful repair of aortic annulus rupture during transcatheter aortic valve replacement using extracorporeal membrane oxygenation support.

    PubMed

    Negi, Smita I; Patel, Jay; Patel, Manish; Loyalka, Pranav; Kar, Biswajit; Gregoric, Igor

    2015-09-01

    Aortic annular rupture is a rare and much dreaded complication of transcatheter aortic valve replacement. Device oversizing to prevent post-procedural paravalvular leak is the most commonly identified cause of this complication. However, mechanical stress in a heavily calcified non-compliant vessel can also lead to annular rupture in this older population. We describe a case of aortic annular rupture with involvement of right coronary artery ostium leading to cardiac tamponade and cardiac arrest, successfully managed by extracorporeal membrane oxygenation support, open drainage of the pericardial space, pericardial patching of the defect and bypass of the affected vessel with excellent post-procedural results. PMID:23990118

  19. Deep Crater in Heavily Calcified Aortic Valve Leaflet: A "Smoking Gun" for Embolic Stroke.

    PubMed

    Xu, Sarah Chaoying; Canter, Lisa; Zeeshan, Ahmad; Elefteriades, John A

    2015-10-01

    The association of severe calcific aortic stenosis with clinically significant stroke has not been well established. This case vividly describes the relationship with clinical and pathological (gross and microscopic) findings in a 62-year-old man with a severely calcified bicuspid aortic valve. Eleven months prior to aortic valve surgery, the patient had stigmata of cerebral embolic events in the absence of any other embolic source. During the aortic valve replacement surgery for aortic stenosis, he was found to have a large atheroma on the aortic valve cusp with a crater containing friable debris in its center. These findings support the potential for embolic stroke in patients with severe calcific aortic stenosis. We recommend that the aortic valve be considered as an embolic source in patients with an otherwise cryptogenic cerebrovascular accident. PMID:27175368

  20. Transcatheter valve-in-valve implantation versus reoperative conventional aortic valve replacement: a systematic review.

    PubMed

    Phan, Kevin; Zhao, Dong-Fang; Wang, Nelson; Huo, Ya Ruth; Di Eusanio, Marco; Yan, Tristan D

    2016-01-01

    Transcatheter valve-in-valve (VIV) implantation for degenerated aortic bioprostheses has emerged as a promising alternative to redo conventional aortic valve replacement (cAVR). However there are concerns surrounding the efficacy and safety of VIV. This systematic review aims to compare the outcomes and safety of transcatheter VIV implantation with redoes cAVR. Six databases were systematically searched. A total of 18 relevant studies (823 patients) were included. Pooled analysis demonstrated VIV achieved significant improvements in mean gradient (38 mmHg preoperatively to 15.2 mmHg postoperatively, P<0.001) and peak gradient (59.2 to 23.2 mmHg, P=0.0003). These improvements were similar to the outcomes achieved by cAVR. The incidence of moderate paravalvular leaks (PVL) were significantly higher for VIV compared to cAVR (3.3% vs. 0.4%, P=0.022). In terms of morbidity, VIV had a significantly lower incidence of stroke and bleeding compared to redo cAVR (1.9% vs. 8.8%, P=0.002 & 6.9% vs. 9.1%, P=0.014, respectively). Perioperative mortality rates were similar for VIV (7.9%) and redo cAVR (6.1%, P=0.35). In conclusion, transcatheter VIV implantation achieves similar haemodynamic outcomes, with lower risk of strokes and bleeding but higher PVL rates compared to redo cAVR. Future randomized studies and prospective registries are essential to compare the effectiveness of transcatheter VIV with cAVR, and clarify the rates of PVLs. PMID:26904259

  1. Transcatheter valve-in-valve implantation versus reoperative conventional aortic valve replacement: a systematic review

    PubMed Central

    Zhao, Dong-Fang; Wang, Nelson; Huo, Ya Ruth; Di Eusanio, Marco; Yan, Tristan D.

    2016-01-01

    Transcatheter valve-in-valve (VIV) implantation for degenerated aortic bioprostheses has emerged as a promising alternative to redo conventional aortic valve replacement (cAVR). However there are concerns surrounding the efficacy and safety of VIV. This systematic review aims to compare the outcomes and safety of transcatheter VIV implantation with redoes cAVR. Six databases were systematically searched. A total of 18 relevant studies (823 patients) were included. Pooled analysis demonstrated VIV achieved significant improvements in mean gradient (38 mmHg preoperatively to 15.2 mmHg postoperatively, P<0.001) and peak gradient (59.2 to 23.2 mmHg, P=0.0003). These improvements were similar to the outcomes achieved by cAVR. The incidence of moderate paravalvular leaks (PVL) were significantly higher for VIV compared to cAVR (3.3% vs. 0.4%, P=0.022). In terms of morbidity, VIV had a significantly lower incidence of stroke and bleeding compared to redo cAVR (1.9% vs. 8.8%, P=0.002 & 6.9% vs. 9.1%, P=0.014, respectively). Perioperative mortality rates were similar for VIV (7.9%) and redo cAVR (6.1%, P=0.35). In conclusion, transcatheter VIV implantation achieves similar haemodynamic outcomes, with lower risk of strokes and bleeding but higher PVL rates compared to redo cAVR. Future randomized studies and prospective registries are essential to compare the effectiveness of transcatheter VIV with cAVR, and clarify the rates of PVLs. PMID:26904259

  2. [Neuroendovascular Treatment for Cerebral Embolism in a Patient just after Aortic Valve Replacement;Report of a Case].

    PubMed

    Kumagai, Motoyuki; Nishizawa, Junichiro; Heima, Daisuke; Takatoku, Kazuhiro; Watanabe, Yoshihiko; Matsui, Yasuzumi; Miyake, Hidenori

    2015-12-01

    A 67-year-old woman suffered from severe aortic stenosis and atrial fibrillation, and underwent aortic valve replacement with a St. Jude Medical Regent 23-mm valve and pulmonary vein isolation using an AtriCure Isolator Synergy.At 6 days after the operation, she experienced sudden onset of atrial fibrillation, left side paralysis, and dysarthria. Right internal carotid artery embolism was diagnosed via magnetic resonance imaging, and we promptly performed neuroendovascular therapy with a Solitaire FR. Neuroendovascular treatment succeeded, and her neurological function was restored to near-normal. Her post-treatment course was uneventful, and she is currently well without neurological dysfunction. PMID:26759947

  3. Vascular Complications Associated with Transfemoral Aortic Valve Replacement.

    PubMed

    Hines, George L; Jaspan, Vita; Kelly, Brian J; Calixte, Rose

    2016-06-01

    Background Transfemoral aortic valve replacement (TAVR) is a novel technique for treating aortic stenosis, yet vascular complications are yet to be delineated. Objectives This study aims to study the vascular complications of TAVR with Edwards Sapien valves (Edwards Lifesciences Corp., Irvine, CA). Methods We performed a retrospective evaluation of TAVR patients. Standard demographics, femoral vessel and sheath size, access type (femoral cut-down [FC], percutaneous access [PFA], and iliac conduit [IC]), and treatment method were recorded. Complications were defined by the Valve Academic Research Consortium Criteria. Logistic regression was used for statistical analysis. Results A total of 99 patients underwent TAVR between February 15, 2012 and July 17, 2013 with an Edwards Sapien valve. Out of which, 48 were males with a mean age of 83 ± 7 years. Overall, 33 had FC, 58 had PFA, and 6 had an IC. A total of 17 major (2 aortic and 15 iliac) and 38 minor complications (36 access and 2 emboli) occurred. Aortic complications were managed by open repair (OR, 1) or percutaneous repair (PR, 1). Overall, 12 iliac injuries were managed by PR and 3 by OR. Out of the 33 groin complications in FC patients 8 (24%) were treated by OR, whereas 30 (52%) of the 58 groin complications in PTA patients were treated by PR. There were no differences in transfusion requirements or length of stay. Conclusion Vascular complications of TAVR are common with most being minor, related to access site and causing no immediate sequelae. Iliac injury can be managed by PR or OR. Aortic injury is associated with significant mortality. These findings increase vascular surgeons' awareness of these complications and how to manage them. PMID:27231425

  4. Deformation Differences between Tricuspid and Bicuspid Aortic Valves in Vitro

    NASA Astrophysics Data System (ADS)

    Szeto, Kai; Rodriguez-Rodriguez, Javier; Pastuszko, Peter; Nigam, Vishal; Lasheras, Juan C.

    2011-11-01

    It has been shown in clinical studies that patients with congenital bicuspid aortic valves (CBAVs) develop degenerative calcification of the leaflets at young ages compared to patients with the normal tricuspid aortic valves (TAVs). It has been hypothesized that the asymmetrical geometry of the leaflets in CBAVs, flow shear stresses (SS), disturbed flow, and excessive strain rate levels are possible causes for the early calcification and stenosis. Central to the validation of this hypothesis is the need to quantify the differences in strain rate levels between the BAVs and TAVs. We simulate the CBAVs by surgically stitching two of the leaflets of a porcine aortic valve together. To quantify strain differences, we performed in-vitro experiments in both trileaflet and bileaflet valves by tracking the motion of small ink dots marked on each leaflet surface. We then used phase-locked stereo photogrammetry to reconstruct at each instant of time the 3D surface of the leaflets and measure the strain rates in both radial and circumferential directions during the whole cardiac cycle. Our results indicate that the total strain rate of the simulated BAVs is about 15 to 20% higher than the normal leaflets of TAVs at systole. In the BAVs' case, the fused leaflet stretches radially up to 25% higher than the reference length. The excessive stretching in both directions in the fused leaflet results in large changes in the flow patterns and associated wall SS.

  5. Three-Dimensional Evaluation of Aortic Valve Annular Shape in Children With Bicuspid Aortic Valves and/or Aortic Coarctation Compared With Controls.

    PubMed

    Chamberland, Christen R; Sugeng, Lissa; Abraham, Sharon; Li, Fangyong; Weismann, Constance G

    2015-11-01

    Bicuspid aortic valve (BAV) is the most common congenital cardiac abnormality, occurring in 1% to 2% of the general population. Adults with degenerative aortic valve (AV) disease have been shown to have an elliptical shaped AV annulus. The goal of this study was to investigate the shape of the aortic annulus in children with BAV, coarctation of the aorta (CoA) with or without BAV, and normal controls with trileaflet AVs using 3-dimensional echocardiography (3DE). We reviewed echocardiograms of children with isolated BAV (n = 40), CoA (n = 26), and controls (n = 40) that included 3DE of the AV. Eccentricity index (EI) was defined as the ratio between the smaller and larger annular dimension. ΔD was defined as the difference between the larger and smaller annular dimension. Patients with BAV had an eccentric AV annulus compared with controls (BAV EI 0.85 ± 0.05 and control EI 0.96 ± 0.03; p <0.001). Subjects with CoA also had a more eccentric annulus than controls regardless of AV morphology (CoA 0.84 ± 0.06; p <0.001). EI was not associated with somatic growth parameters or gender. Among all patients with BAV, AV dysfunction was associated with fusion of the right and noncoronary (R-N) cusps (p <0.001), but there was no association between valve dysfunction and EI. ΔD was higher in both the BAV and CoA groups compared with the control group (BAV 3.4 ± 1.9 mm, CoA 2.8 ± 1.8 mm, and control 0.6 ± 0.4 mm; p <0.001 each). Although there was no significant correlation of ΔD with age in the control group during childhood, ΔD increased with age in the BAV and CoA groups. In conclusion, children with BAV and/or CoA have an elliptical shaped AV annulus by 3DE, which is independent of age, gender, or body surface area. AV annular eccentricity may lead to inaccurate measurement of AV annular size if measured by 2DE alone. Considering AV annular eccentricity when balloon sizing the annulus before valvuloplasty may help improve interventional results in some

  6. Transcatheter Aortic Valve Implantation Experience with SAPIEN 3.

    PubMed

    Ohno, Y; Tamburino, C; Barbanti, M

    2015-06-01

    Based on randomized trials with first generation devices, transcatheter aortic valve replacement (TAVI) has been included into the treatment strategy for high-risk and inoperable patients with severe aortic stenosis. Procedural complications remain a concern with TAVI, including stroke, vascular complications, paravalvular leak (PVL) and conduction disturbances. Addressing these limitations will support TAVI use in lower risk populations. This review discussed features and most recent clinical evidence of the new balloon-expandable THV (SAPIEN 3, Edwards Lifescience, Irvine, CA, USA). PMID:25900559

  7. Left Ventricular Outflow Tract Pseudoaneurysm after Aortic Valve Replacement

    PubMed Central

    Shariff, Masood A.; Martingano, Daniel; Khan, Usman; Goyal, Nikhil; Sharma, Raman; Rizvi, Syed B.; Motivala, Apurva; Asgarian, Kourosh T.; Nabagiez, John P.

    2015-01-01

    Left ventricular outflow tract pseudoaneurysm is an uncommon complication following aortic valve replacement (AVR), occurring most frequently secondary to endocarditis. We present a case of a 47-year-old female with a history of intravenous drug abuse and a past surgical history of two AVRs (2001 and 2009 with aortic root replacement for endocarditis) who presented with symptoms of lower extremity weakness. Subsequent radiologic imaging revealed the presence of a left ventricular outflow tract pseudoaneurysm, which was surgically managed with a homologous conduit. PMID:27175367

  8. Fluid Dynamics of Coarctation of the Aorta and Effect of Bicuspid Aortic Valve

    PubMed Central

    Keshavarz-Motamed, Zahra; Garcia, Julio; Kadem, Lyes

    2013-01-01

    Up to 80% of patients with coarctation of the aorta (COA) have a bicuspid aortic valve (BAV). Patients with COA and BAV have elevated risks of aortic complications despite successful surgical repair. The development of such complications involves the interplay between the mechanical forces applied on the artery and the biological processes occurring at the cellular level. The focus of this study is on hemodynamic modifications induced in the aorta in the presence of a COA and a BAV. For this purpose, numerical investigations and magnetic resonance imaging measurements were conducted with different configurations: (1) normal: normal aorta and normal aortic valve; (2) isolated COA: aorta with COA (75% reduction by area) and normal aortic valve; (3) complex COA: aorta with the same severity of COA (75% reduction by area) and BAV. The results show that the coexistence of COA and BAV significantly alters blood flow in the aorta with a significant increase in the maximal velocity, secondary flow, pressure loss, time-averaged wall shear stress and oscillatory shear index downstream of the COA. These findings can contribute to a better understanding of why patients with complex COA have adverse outcome even following a successful surgery. PMID:24015239

  9. Severe Systolic Anterior Motion After Aortic Valve Replacement and Cox MAZE Surgery.

    PubMed

    den Uil, Corstiaan A; Ter Horst, Maarten; Akin, Sakir; Galema, Tjebbe W

    2016-07-01

    Surgical aortic valve replacement may be complicated by severe dynamic left ventricular outflow tract obstruction and cardiogenic shock in the postoperative period. We present a patient who developed severe anterior motion following aortic valve and Cox MAZE surgery which necessitated a mitral valve replacement. doi: 10.1111/jocs.12763 (J Card Surg 2016;31:429-431). PMID:27212634

  10. Consecutive transcatheter valve-in-valve implantations: the first in the aortic position, the second in the mitral position, in a patient with failing aortic and mitral bioprostheses

    PubMed Central

    Duncan, Alison; Davies, Simon; Rosendahl, Ulrich; Moat, Neil

    2014-01-01

    A 69-year-old man with a failing aortic valve homograft and failing mitral valve xenograft was admitted with an inability to complete full sentences and pulmonary oedema with right ventricular overload. Severe aortic and mitral regurgitation, severe biventricular impairment and pulmonary hypertension were confirmed on transthoracic and transoesophageal echocardiography. An urgent transfemoral valve-in-valve transcatheter valve implantation (TAVI) was performed within the aortic valve homograft with full resolution of aortic regurgitation. Three months later, a semielective trans-apical valve-in-valve procedure was performed in the mitral position, under cardiopulmonary bypass, with full resolution of mitral regurgitation. His exercise tolerance increased from 5 yards to half a mile. This case report summarises a staged double valve-in-valve procedure in a patient who had three previous sternotomies and who had severe heart failure due to failing aortic and mitral bioprostheses. We report two different delivery approaches, using two different transcatheter devices, and describe valve-in-valve techniques, including cardiopulmonary bypass, in the catheter laboratory. PMID:25053698

  11. Perinatal Changes in Mitral and Aortic Valve Structure and Composition

    PubMed Central

    Stephens, Elizabeth H.; Post, Allison D.; Laucirica, Daniel R.; Grande-Allen, K. Jane

    2015-01-01

    At birth, the mechanical environment of valves changes radically as fetal shunts close and pulmonary and systemic vascular resistances change. Given that valves are reported to be mechanosensitive, we investigated remodeling induced by perinatal changes by examining compositional and structural differences of aortic and mitral valves (AVs, MVs) between 2-day-old and 3rd fetal trimester porcine valves using immunohistochemistry and Movat pentachrome staining. Aortic valve composition changed more with birth than the MV, consistent with a greater change in AV hemodynamics. At 2 days, AV demonstrated a trend of greater versican and elastin (P = 0.055), as well as greater hyaluronan turnover (hyaluronan receptor for endocytosis, P = 0.049) compared with the 3rd-trimester samples. The AVs also demonstrated decreases in proteins related to collagen synthesis and fibrillogenesis with birth, including procollagen I, prolyl 4-hydroxylase, biglycan (all P ≤ 0.005), and decorin (P = 0.059, trend). Both AVs and MVs demonstrated greater delineation between the leaflet layers in 2-day-old compared with 3rd-trimester samples, and AVs demonstrated greater saffron-staining collagen intensity, suggesting more mature collagen in 2-day-old compared with 3rd-trimester samples (each P < 0.05). The proportion of saffron-staining collagen also increased in AV with birth (P < 0.05). The compositional and structural changes that occur with birth, as noted in this study, likely are important to proper neonatal valve function. Furthermore, normal perinatal changes in hemodynamics often do not occur in congenital valve disease; the corresponding perinatal matrix maturation may also be lacking and could contribute to poor function of congenitally malformed valves. PMID:20536360

  12. Bioprosthetic Aortic Valve Endocarditis in Association with Enterococcus durans

    PubMed Central

    Di Gioacchino, Lorena; Balestrini, Fabrizio

    2016-01-01

    Enterococci are common organisms associated with endocarditis, but infection by Enterococcus durans is very rare. To our knowledge, only 3 cases have been reported in the medical literature, and all 3 have involved native valves. Here we publish the first reported case (to our knowledge) of E. durans endocarditis in association with a bioprosthetic aortic valve. After the organism and its antibiotic susceptibility were identified, the 74-year-old male patient was treated successfully with teicoplanin and gentamicin, over a course of 6 weeks. PMID:27127436

  13. Unicuspid aortic valve presenting with cardiac arrest in an adolescent.

    PubMed

    Connelly, Tara; Kolcow, Walenty; Smyth, Yvonne; Veerasingham, David

    2015-01-01

    Unicuspid aortic valve (UAV) is a rare congenital anomaly typically affecting patients in their fourth and fifth decades and presenting with signs of heart failure. Our case is one of a previously asymptomatic teenage girl with a UAV, who presented with cardiac arrest and was successfully treated. Only two other similar cases have been reported in the literature, both were of slightly older male patients. Our case highlights the morbidity associated with the anomaly supporting the need for careful assessment of the valve in cases where UAV is suspected. PMID:26178230

  14. Impact of Different Iterations of Devices and Degree of Aortic Valve Calcium on Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation.

    PubMed

    Kong, William K F; van Rosendael, Philippe J; van der Kley, Frank; de Weger, Arend; Kamperidis, Vasileios; Regeer, Madelien V; Marsan, Nina Ajmone; Bax, Jeroen J; Delgado, Victoria

    2016-08-15

    The iterations of the SAPIEN prosthesis might impact the incidence and grade of paravalvular regurgitation (PVR). The aim of this study was to assess the impact of iterations of balloon-expandable valves (SAPIEN, SAPIEN XT, and SAPIEN 3) and degree of aortic valve calcification (AVC) on the severity of PVR after transcatheter aortic valve implantation (TAVI). Comprehensive echocardiographic examinations and multidetector computed tomography (MDCT) were performed in 272 patients (127 men, 81 ± 7 years old, logistic EuroScore of 21 ± 13%) who underwent TAVI with 23- and 26-mm balloon-expandable valves. The degree of AVC was assessed with MDCT. PVR grade was assessed with echocardiography. The cover index was calculated as (prosthesis area - MDCT annulus area)/prosthesis area. SAPIEN, SAPIEN XT, and SAPIEN 3 prostheses were implanted in 103 patients (38%), 105 patients (38.5%), and 64 patients (23.5%), respectively. Significant PVR (≥moderate) occurred in 14%, 10%, and 0% of patients receiving the SAPIEN, SAPIEN XT, and SAPIEN 3, respectively (p = 0.010). Across the groups, the aortic annulus size, degree of calcification, and cover index were comparable. Larger burden of AVC was independently associated with significant PVR (odds ratio 3.48, p = 0.006) after adjusting for age, body surface area, gender, aortic annulus area, cover index, and prosthesis iteration. SAPIEN 3 was associated with lower frequency of significant PVR (odds ratio 0.31, p = 0.002). In conclusion, the incidence of significant PVR significantly decreased over time with improvement in valve design. SAPIEN 3 was associated with less significant PVR after TAVI independently of the AVC burden. PMID:27328953

  15. Midterm follow-up dynamic echocardiography evaluation after aortic valve repair for aortic valve insufficiency.

    PubMed

    D'Ancona, Giuseppe; Amaducci, Andrea; Prodromo, John; Pirone, Francesco; Follis, Marco; Falletta, Calogero; Pilato, Michele

    2012-06-01

    We prospectively evaluated 46 patients who underwent aortic valve repair (AVR) for AV regurgitation. Rest/stress echocardiography follow-up was performed. Follow-up duration was 30.7 months, age 56 ± 14 years, ejection fraction% 57.5 ± 10.5%. Preoperative bicuspid AV was present in 14 (30.4%), leaflets calcifications in 8 (17.4%), thickening in 17 (37.0%) and prolapse in 22 (47.8%). Surgical technique included commissuroplasty (22, 47.8%), leaflet remodelling (17, 37.0%), decalcification (7, 15.2%) and raphe removal (14, 30.4%). At follow-up, rest/stress echocardiography median AV regurgitation (rest 1.0 vs. stress 1.0) and mean indexed AV area (IAVA) (rest 2.6 ± 0.74 cm(2)/m(2) vs. stress 2.8 ± 0.4 cm(2)/m(2)) were unchanged (P = ns). Mean (rest 4.7 ± 3.9 mmHg vs. stress 9.7 ± 5.8 mmHg) and peak (rest 9.5 ± 7.2 mmHg vs. stress 19.0 ± 10.5 mmHg) transvalvular gradients were significantly increased (P < 0.0001). At linear regression, there was an independent inverse correlation between commissuroplasty and AV gradients during stress (B = -9.9, P = 0.01, confidence interval= -17.7 to -2.1). Although follow-up haemodynamics of repaired AVs are satisfactory, there was a fixed IAVA and significant increase in AV gradients. We were not able to identify any pre-existing anatomical condition independently related to this non-physiological behaviour under stress. Moreover, commissuroplasty seems to prevent abnormal increase of the AV gradients. PMID:22368109

  16. [Minimally Invasive Aortic Valve Replacement Via Right Mini-thoracotomy].

    PubMed

    Totsugawa, Toshinori

    2016-07-01

    Here we demonstrate our surgical procedure of minimally invasive aortic valve replacement through right anterolateral mini-thoracotomy. Preoperative evaluation of the whole aorta by contrast-enhanced computed tomography scan is important to prevent cerebrovascular complications. The patient is set in a mild left lateral decubitus position. A skin incision is made along the anterior axillary line to the inframammary fold and the chest is opened at the 3rd or 4th intercostal space. Cardiopulmonary bypass is usually established by femoro-femoral bypass. The ascending aorta is clamped with a Chitwood clamp and antegrade or selective cardioplegia is administered. Four traction sutures placed at the aortotomy widely open the aortotomy and offer fine surgical view of the aortic valve. The annular calcifications are excised using a cavitron ultrasonic surgical aspirator. Double-needle braided sutures with pledgets are placed in a non-everting mattress manner. Then the prosthetic valve is sewn onto the aortic annulus. Finger knot tying through anterolateral mini-thoracotomy is usually challenging;therefore, all sutures are tied using a knot pusher. The aortotomy is closed and the aorta is de-clamped. The pericardium is loosely closed;chest tubes are placed;and the thoracotomy is closed in a usual manner. PMID:27440021

  17. Aortic stenosis associated with Scheie's syndrome. Report of successful valve replacement.

    PubMed

    Masuda, H; Morishita, Y; Taira, A; Kuriyama, M

    1993-03-01

    A 62-year-old man who had aortic stenosis associated with Scheie's syndrome (mucopolysaccharidosis [MPS], type I-S) successfully underwent aortic valve replacement. The composition of acidic glycosaminoglycans (acid mucopolysaccharides) of the excised aortic valve analyzed by high-performance liquid chromatography (HPLC) supported the diagnosis of Scheie's syndrome. This article reviews the literature on aortic stenosis in MPS, a rare inherited metabolic disorder, and discusses biochemical features and surgical repair. PMID:8449111

  18. Left ventricular outflow tract false aneurysm late after aortic valve replacement.

    PubMed

    Bizzarri, Federico; Braconi, Lucio; Rossi, Alessandra; Sorbara, Carlo; Stefano, Pier Luigi

    2005-01-01

    We describe an unusual case of left ventricular outflow tract (LVOT) pseudoaneurysm late after aortic valve replacement. A 77-year-old man, who had undergone aortic valve replacement with mechanical prosthesis 7 years ago, presented, asymptomatic, with a transesophageal echocardiography (TTE) diagnosis of a large cavitary mass arising behind the aortic wall. The orifice of the pseudoaneurysm was successfully surgically closed and the aortic root reconstructed with cryopreserved homograft. PMID:15870043

  19. Valve-sparing aortic root replacement in the presence of coronary anomalies.

    PubMed

    Mazzitelli, Domenico; Nöbauer, Christian; Rankin, J Scott; Schreiber, Christian; Lange, Rüdiger

    2014-11-01

    Aortic root replacement in the presence of coronary anomalies can be challenging. Because the anomalous coronary often arises close to a commissure, reconstruction with traditional buttons can be technically difficult without compromising either the leaflets or the coronary artery. A method of valve sparing root surgery termed "aortic valve and root restoration," using aortic ring annuloplasty and formal valve repair, and then incorporating the anomalous coronary into the commissural suture line, may offer a simple solution to this problem. PMID:25441812

  20. New St. Jude Medical Portico™ transcatheter aortic valve: features and early results.

    PubMed

    Spence, M S; Lyons, K; McVerry, F; Smith, B; Manoharan, G B; Maguire, C; Doherty, R; Anderson, L; Morton, A; Hughes, S; Hoeritzauer, I; Manoharan, G

    2013-06-01

    Patients with symptomatic aortic valve disease who are inoperable or have high surgery-related risks may be treated with transcatheter aortic valve implantation devices. With this method increasingly applied, device innovations are aimed at achieving improved procedural results and therapeutic outcome. This paper describes the innovations implemented in the St. Jude Medical Portico™ system for transcatheter aortic valve implantation, the application of this system and initial clinical experience. PMID:23681129

  1. Transcatheter aortic valve replacement: current application and future directions.

    PubMed

    Fassa, Amir-Ali; Himbert, Dominique; Vahanian, Alec

    2013-04-01

    During the last decade, the rapid evolution of transcatheter aortic valve replacement (TAVR) has revolutionized the treatment of severe aortic stenosis. Since the PARTNER A and B trials, this technique has become the treatment of reference for inoperable patients, and an attractive alternative to surgical aortic valve replacement in those at high risk for surgery. Large multicenter registries conducted since 2007, mainly in Europe, confirmed the excellent hemodynamic performances of the 2 percutaneous valves currently available on the market, the Edwards SAPIEN, and the Medtronic CoreValve, as well as their benefits in terms of symptom relief and survival. The whole process of TAVR, from patient selection to post-procedural care and result evaluation, should be conducted by a dedicated multidisciplinary "heart team," within centers with expertise in valve disease. Though currently limited to those deemed at high risk for surgery or inoperable, indications for TAVR will likely be extended to a broader spectrum of patients, in particular those with surgical bioprosthetic failure or at intermediate risk for surgery. Beforehand, it will be essential to obtain more extensive data on the durability of percutaneous prostheses, since the available follow-up is seldom longer than 5 years, and in order to further decrease the rate of complications, mainly stroke, paravalvular regurgitation, and access site complications. Furthermore, the use of the transfemoral route will undoubtedly increase because of the miniaturization of the devices, at the expense of other approaches. Above all, multidisciplinary approach, excellent imaging, and careful evaluation will remain key to the success of this technique. PMID:23420448

  2. Transcatheter ACURATE-TA Aortic Valve Implantation in a Patient With a Previous Mechanical Mitral Valve.

    PubMed

    Bagur, Rodrigo; Kiaii, Bob; Teefy, Patrick J; Diamantouros, Pantelis; Harle, Christopher; Goela, Aashish; Chan, Ian; Chu, Michael W A

    2015-11-01

    Transcatheter aortic valve implantation (TAVI) in the presence of a mechanical mitral valve (MMV) prosthesis is still challenging because of the rigid mitral frame within the aortomitral curtain. Moreover, low-lying coronary ostia represent a hazardous problem of coronary obstruction, especially in narrow or porcelain aortic roots. The present case demonstrates the successful management of 2 challenging anatomical issues, the rigid cage of the MMV and the low-lying left main coronary ostium (LMCO), with the implantation of the ACURATE-TA bioprosthesis (Symetis SA, Ecublens, Switzerland). It also highlights the importance of having multiple TAVI devices in order to choose the ideal transcatheter aortic bioprosthesis to fit the unique anatomical presentation of the patient. PMID:26522576

  3. Sex Differences in Aortic Stenosis and Outcome Following Surgical and Transcatheter Aortic Valve Replacement.

    PubMed

    Dobson, Laura E; Fairbairn, Timothy A; Plein, Sven; Greenwood, John P

    2015-12-01

    Aortic stenosis is the commonest valve defect in the developed world and is associated with a high mortality once symptomatic. There is a difference in the way that male and female hearts remodel in the face of chronic pressure overload: women develop a concentrically hypertrophied, small cavity left ventricle (LV), whereas men are more prone to the development of eccentric hypertrophy. At a cellular level, there is an increase in collagen and metalloproteinase gene expression in males suggesting a different regulation of extracellular volume composition according to sex. Male hearts with aortic stenosis appear to have more fibrosis than their female comparators. The trigger for this appears to be in part related to estrogen receptor signaling, but other factors such as renin-angiotensin activation, nitric oxide, and circulating noradrenaline levels may also be implicated. Treatment options include surgical valve replacement (SAVR) and more recently transcatheter aortic valve replacement (TAVR). Female sex may be a risk factor for adverse outcome following SAVR and conversely appears to confer a survival advantage when undergoing TAVR. Whether the lower mortality seen following TAVR in women compared with men (despite their increased age and frailty) reflects their longer life expectancy, smaller annular size (and less post-TAVR aortic regurgitation), more favorable LV reverse remodeling, or more likely, a combination of these factors remains to be established. PMID:26653869

  4. Calcific aortic valve disease: A consensus summary from the Alliance of Investigators on Calcific Aortic Valve Disease

    PubMed Central

    Yutzey, Katherine E.; Demer, Linda L.; Body, Simon C.; Huggins, Gordon S.; Towler, Dwight A.; Giachelli, Cecilia M.; Hofmann-Bowman, Marion A.; Mortlock, Douglas P.; Rogers, Melissa B.; Sadeghi, Mehran M.; Aikawa, Elena

    2014-01-01

    Calcific Aortic Valve Disease (CAVD) is increasingly prevalent worldwide with significant morbidity and mortality. Therapeutic options beyond surgical valve replacement are currently limited. In 2011, the National Heart Lung and Blood Institute assembled a working group on aortic stenosis. This group identified CAVD as an actively regulated disease process in need of further study. As a result, the Alliance of Investigators on CAVD was formed to coordinate and promote CAVD research, with the goals of identifying individuals at risk, developing new therapeutic approaches, and improving diagnostic methods. The group is composed of cardiologists, geneticists, imaging specialists, and basic science researchers. This report reviews the current status of CAVD research and treatment strategies with identification of areas in need of additional investigation for optimal management of this patient population. PMID:25189570

  5. Reverse U aortotomy (Kırali incision) for aortic valve replacement.

    PubMed

    Kırali, Kaan

    2016-06-01

    The presence of patent vein grafts on the proximal aorta may cause technical difficulties during reoperations for aortic valve replacement after previous coronary artery bypass surgery. A 65-year-old man underwent reoperation for aortic valve replacement two years after his first open heart surgery (valve-sparing aortic root replacement and aorta-right coronary artery saphenous vein graft). The aortotomy incision was started approximately 2 cm above the proximal anastomosis and continued down at both sides until the prosthetic graft. The reverse U aortotomy prevents unnecessary and risky manipulations of proximal anastomoses, provides perfect exposure, and can be used securely during reoperative aortic valve surgery. PMID:25759482

  6. Propellant isolation shutoff valve program

    NASA Technical Reports Server (NTRS)

    Merritt, F. L.

    1973-01-01

    An analysis and design effort directed to advancing the state-of-the-art of space storable isolation valves for control of flow of the propellants liquid fluorine/hydrazine and Flox/monomethylhydrazine is discussed. Emphasis is on achieving zero liquid leakage and capability of withstanding missions up to 10 years in interplanetary space. Included is a study of all-metal poppet sealing theory, an evaluation of candidate seal configurations, a valve actuator trade-off study and design description of a pneumo-thermally actuated soft metal poppet seal valve. The concepts and analysis leading to the soft seal approach are documented. A theoretical evaluation of seal leakage versus seal loading, related finishes and yield strengths of various materials is provided. Application of a confined soft aluminum seal loaded to 2 to 3 times yield strength is recommended. Use of either an electro-mechanical or pneumatic actuator appears to be feasible for the application.

  7. Minimally invasive aortic valve replacement: the Leipzig experience

    PubMed Central

    Merk, Denis R.; Etz, Christian D.; Seeburger, Joerg; Schroeter, Thomas; Oberbach, Andreas; Uhlemann, Madlen; Hoellriegel, Robert; Haensig, Martin; Leontyev, Sergey; Garbade, Jens; Misfeld, Martin; Mohr, Friedrich W.

    2015-01-01

    Background Minimally invasive techniques are progressively challenging traditional approaches in cardiothoracic surgery. Minimally invasive aortic valve replacement (AVR) has become a routine procedure at our institution. Methods We retrospectively analyzed all patients undergoing minimally invasive isolated AVR between January 2003 and March 2014, at our institution. Mean follow-up was 4.7±4.3 years (range: 0-18 years) and was 99.8% complete. Results There were 1,714 patients who received an isolated minimally invasive AVR. The mean (± SD) patient age was 65±12.8 years, ejection fraction 60%±12% and log EuroSCORE 5.3%±5.1%. Mean cross-clamp time was 58±18 minutes and mean cardiopulmonary bypass (CPB) time was 82.9±26.7 minutes. Thirty-day survival was 97.8%±0.4%, and 69.4%±1.7% at 10-years. The multivariate analysis revealed age at surgery [P=0.016; odds ratio (OR), 1.1], length of surgery time (P=0.002; OR, 1.01), female gender (P=0.023; OR, 3.54), preoperative myocardial infarction (MI) (P=0.006; OR, 7.87), preoperative stroke (P=0.001; OR, 13.76) and preoperative liver failure (P=0.015; OR, 10.28) as independent risk factors for mortality. Cox-regression analysis revealed the following predictors for long term mortality: age over 75 years (P<0.001; OR, 3.5), preoperative dialysis (P<0.01; OR, 2.14), ejection fraction less than 30% (P=0.003; OR, 3.28) and urgent or emergency operation (P<0.001; OR, 2.3). Conclusions Minimally invasive AVR can be performed safely and effectively with very few perioperative complications. The early and long-term outcomes in these patients are acceptable. PMID:25694976

  8. Enlargement of the aortic annulus during aortic valve replacement: a review.

    PubMed

    Bortolotti, Uberto; Celiento, Michele; Milano, Aldo D

    2014-01-01

    The main goal of aortic valve replacement (AVR) is to obtain relief from the fixed left ventricular (LV) obstruction by replacing the aortic valve with a prosthesis, either mechanical or biological, of adequate size. Most currently available prostheses provide satisfactory hemodynamic performance, but small-sized prostheses may be associated with high transvalvular gradients and suboptimal effective orifice area that result in prosthesis-patient mismatch (PPM), and thus are far from ideal for use in young, active patients. The avoidance of PPM is advisable as it has been repeatedly associated with increased mortality, decreased exercise tolerance and an impaired regression of LV hypertrophy after AVR for severe aortic stenosis. Enlargement of the aortic annulus (EAA) has proved to be a valuable method to prevent PPM in the presence of a diminutive aortic root. This review outlines the various techniques described for EAA, presenting technical details, long-term results and major procedure-related complications, and discussing the current role of EAA in patients requiring AVR. PMID:24779326

  9. Aortic valve replacement for a patient with anomalous left coronary artery from the right sinus of Valsalva.

    PubMed

    Hamamoto, Masaki; Futagami, Daisuke

    2013-01-01

    Anomalous origin of the left coronary artery (LCA) from the right sinus of Valsalva (RSOV) is an uncommon but clinically important feature. A 75-year-old man with progressive nocturnal dyspnea was diagnosed with severe aortic valve stenosis and moderate regurgitation. Preoperative computed tomographic scan revealed that the LCA originated from the RSOV separate from the right coronary artery and coursed into the ventricular septum. Because he did not experience any episodes of cardiac ischemia, isolated aortic valve replacement was performed using a 23-mm stented bioprosthesis without concomitant coronary revascularization. The postoperative course was free from coronary ischemia. PMID:22618986

  10. In vitro models of aortic valve calcification: solidifying a system.

    PubMed

    Bowler, Meghan A; Merryman, W David

    2015-01-01

    Calcific aortic valve disease (CAVD) affects 25% of people over 65, and the late-stage stenotic state can only be treated with total valve replacement, requiring 85,000 surgeries annually in the US alone (University of Maryland Medical Center, 2013, http://umm.edu/programs/services/heart-center-programs/cardiothoracic-surgery/valve-surgery/facts). As CAVD is an age-related disease, many of the affected patients are unable to undergo the open-chest surgery that is its only current cure. This challenge motivates the elucidation of the mechanisms involved in calcification, with the eventual goal of alternative preventative and therapeutic strategies. There is no sufficient animal model of CAVD, so we turn to potential in vitro models. In general, in vitro models have the advantages of shortened experiment time and better control over multiple variables compared to in vivo models. As with all models, the hypothesis being tested dictates the most important characteristics of the in vivo physiology to recapitulate. Here, we collate the relevant pieces of designing and evaluating aortic valve calcification so that investigators can more effectively draw significant conclusions from their results. PMID:25249188

  11. Which patients benefit from stentless aortic valve replacement?

    PubMed

    Gulbins, Helmut; Reichenspurner, Hermann

    2009-12-01

    This review article analyzes the literature to answer the question of whether stentless aortic bioprostheses possess proven advantages compared with stented bioprosthesis, and which patients might benefit from stentless valve implantation. For this purpose, the United States National Library of Medicine's PubMed and MEDLINE databases were searched for articles dealing with results of stentless aortic bioprostheses or studies comparing stented and stentless prostheses. Key word searches used were as follows: stentless aortic prostheses, stented aortic prosthesis, hemodynamic, hemodynamic performance, degeneration, durability, technique, and long-term follow-up. The analysis focused on stentless prostheses with a clinical experience for more than 5 years. Only a few randomized studies were found. Stentless prostheses were found to be advantageous in patients with severe impaired left ventricular function or a small aortic annulus (ie, evidence of grade II), but no specific advantages could be determined for the majority of patients. The durability results were mixed: the Toronto SPV (St. Jude Medical, Minneapolis, MN) showed an increase in degeneration after 10 years of follow-up, whereas the Freestyle porcine stentless prostheses (Medtronic, Minneapolis, MN) still showed excellent results after this period. PMID:19932303

  12. State-of-the-art aortic imaging: Part II - applications in transcatheter aortic valve replacement and endovascular aortic aneurysm repair.

    PubMed

    Rengier, Fabian; Geisbüsch, Philipp; Schoenhagen, Paul; Müller-Eschner, Matthias; Vosshenrich, Rolf; Karmonik, Christof; von Tengg-Kobligk, Hendrik; Partovi, Sasan

    2014-01-01

    Transcatheter aortic valve replacement (TAVR) as well as thoracic and abdominal endovascular aortic repair (TEVAR and EVAR) rely on accurate pre- and postprocedural imaging. This review article discusses the application of imaging, including preprocedural assessment and measurements as well as postprocedural imaging of complications. Furthermore, the exciting perspective of computational fluid dynamics (CFD) based on cross-sectional imaging is presented. TAVR is a minimally invasive alternative for treatment of aortic valve stenosis in patients with high age and multiple comorbidities who cannot undergo traditional open surgical repair. Given the lack of direct visualization during the procedure, pre- and peri-procedural imaging forms an essential part of the intervention. Computed tomography angiography (CTA) is the imaging modality of choice for preprocedural planning. Routine postprocedural follow-up is performed by echocardiography to confirm treatment success and detect complications. EVAR and TEVAR are minimally invasive alternatives to open surgical repair of aortic pathologies. CTA constitutes the preferred imaging modality for both preoperative planning and postoperative follow-up including detection of endoleaks. Magnetic resonance imaging is an excellent alternative to CT for postoperative follow-up, and is especially beneficial for younger patients given the lack of radiation. Ultrasound is applied in screening and postoperative follow-up of abdominal aortic aneurysms, but cross-sectional imaging is required once abnormalities are detected. Contrast-enhanced ultrasound may be as sensitive as CTA in detecting endoleaks. PMID:24429327

  13. A Simple Device for Morphofunctional Evaluation During Aortic Valve-Sparing Surgery.

    PubMed

    Leone, Alessandro; Bruno, Piergiorgio; Cammertoni, Federico; Massetti, Massimo

    2015-07-01

    Valve-sparing operations for the treatment of aortic root disease with a structurally normal aortic valve are increasingly performed as they avoid prosthesis-related complications. Short- and long-term results are critically dependent on perfect intraoperative restoration of valve anatomy and function. Residual aortic regurgitation is the main cause of early failure, and it is the most common motive for reoperation. However, intraoperative morphofunctional valve assessment requires expertise, and only transesophageal echocardiography can provide reliable information. We describe a simple, economic, reproducible hydrostatic test to intraoperatively evaluate valve competency under direct visualization. PMID:26140788

  14. Replacement of a Björk-Shiley Delrin Aortic Valve Still Functioning after 25 Years

    PubMed Central

    Badak, M. Ismail; Ozkisacik, Erdem Ali; Boga, Mehmet; Gurcun, Ugur; Discigil, Berent

    2004-01-01

    We report the case of a patient who had undergone implantation of a Björk-Shiley Delrin valve in the aortic position 25 years earlier and who now presented with severe mitral stenosis. The patient underwent mitral valve replacement and aortic valve re-replacement. We review the justification for prophylactic replacement of Björk-Shiley Delrin heart valves. PMID:15562853

  15. Long-term follow-up of unusual ball-valve aortic substitute.

    PubMed

    Shumacker, H B; Isch, J H; Jolly, W W

    1978-08-01

    On March 19, 1962, prior to the availability of Starr-Edwards ball-valve prostheses for aortic substitution, a mitral valve turned upside down was implanted for marked calcific aortic stenosis. It worked well and the patient was in good health for 15 years. Late annular calcification and loosening of sutures with marked perivalvular regurgitation made valve replacement necessary 16 years after operation. The original valve was perfectly preserved. PMID:682654

  16. A second-time percutaneous aortic-valve implantation for bioprosthetic failure

    PubMed Central

    Codner, Pablo; Assali, Abid; Vaknin Assa, Hana; Kornowski, Ran

    2015-01-01

    Key Clinical Message We report a case of an 84-year-old man with a history of surgical aortic-valve replacement for chronic aortic regurgitation (AR) who later developed severe prosthetic valve AR. Subsequent treatment with a Corevalve® was unsuccessful with severe AR seen at 3 years after the valve-in-valve procedure. The patient was then successfully treated with a second catheter-based Corevalve® implantation. PMID:26401281

  17. Limited Expansion of the New Self-Expandable Transcathether Aortic Valve Prosthesis (CoreValve Evolut R).

    PubMed

    Serio, Daniela; Doss, Mirko; Kim, Won-Keun; Möllmann, Helge; Walther, Thomas

    2016-05-01

    Transcatheter aortic valve implantation (TAVI) has been established as a therapeutic option in patients with a high procedural risk presenting with severe aortic stenosis. Recent improvements of TAVI technology made it possible to treat degenerated bioprosthesis using the valve-in-valve implantation concept. The self-expanding CoreValve (Medtronic, Minneapolis, MN) prosthesis has recently been redesigned and was introduced into clinical practice. We report a case of a not fully expanded Medtronic CoreValve Evolut R after deploying a 26 mm prosthesis into a degenerated 25 mm Carpentier-Edwards Perimount prosthesis. PMID:27106459

  18. Apicoaortic conduit and cerebral perfusion in mixed aortic valve disease: a computational analysis

    PubMed Central

    Fragomeni, Gionata; Rossi, Michele; Condemi, Francesca; Mazzitelli, Rosario; Serraino, Giuseppe Filiberto; Renzulli, Attilio

    2013-01-01

    OBJECTIVES The revival of the apicoaortic conduit has attracted new interest in this alternative treatment for severe aortic stenosis unsuitable for conventional valve replacement. However, doubts still exist about the perfusion of the epiaortic vessels after apicoaortic conduit implantation, especially when severe aortic stenosis is associated with aortic valve insufficiency. The aim of the study was to evaluate the perfusion of the epiaortic vessels (innominate artery, left carodit artery and left subclavian artery) in cases of mixed aortic valve disease before and after apicoaortic conduit implantation. METHODS Starting from the data of a real patient with severe aortic stenosis and mild aortic insufficiency who underwent apicoaortic conduit implantation, we created a computational model where severe aortic valve stenosis was associated with different grades of aortic insufficiency (mild, medium and moderate). RESULTS A total of six combinations were analysed. In all simulations, the more severe the concomitant aortic insufficiency, the more the flow through the epiaortic vessels was diminished. After apicoaortic conduit implantation, there was an absolute augmentation of the median output in each epiaortic vessel compared with the same combination of mixed aortic valve disease before implantation. Interestingly, retrograde flow from the conduit in the descending aorta was minimal and did not contribute to the improved output of the epiaortic vessels. CONCLUSIONS The computational analysis suggested a protective effect, rather than steal phenomenon, of the apicoaortic conduit towards the cerebral perfusion, even in cases of mixed aortic valve disease. PMID:23962852

  19. Feature identification for image-guided transcatheter aortic valve implantation

    NASA Astrophysics Data System (ADS)

    Lang, Pencilla; Rajchl, Martin; McLeod, A. Jonathan; Chu, Michael W.; Peters, Terry M.

    2012-02-01

    Transcatheter aortic valve implantation (TAVI) is a less invasive alternative to open-heart surgery, and is critically dependent on imaging for accurate placement of the new valve. Augmented image-guidance for TAVI can be provided by registering together intra-operative transesophageal echo (TEE) ultrasound and a model derived from pre-operative CT. Automatic contour delineation on TEE images of the aortic root is required for real-time registration. This study develops an algorithm to automatically extract contours on simultaneous cross-plane short-axis and long-axis (XPlane) TEE views, and register these features to a 3D pre-operative model. A continuous max-flow approach is used to segment the aortic root, followed by analysis of curvature to select appropriate contours for use in registration. Results demonstrate a mean contour boundary distance error of 1.3 and 2.8mm for the short and long-axis views respectively, and a mean target registration error of 5.9mm. Real-time image guidance has the potential to increase accuracy and reduce complications in TAVI.

  20. Current Clinical Evidence on Rapid Deployment Aortic Valve Replacement

    PubMed Central

    Barnhart, Glenn R.; Shrestha, Malakh Lal

    2016-01-01

    Abstract Aortic stenosis is the most common valvular heart disease in the Western world. It is caused primarily by age-related degeneration and progressive calcification typically detected in patients 65 years and older. In patients presenting with symptoms of heart failure, the average survival rate is only 2 years without appropriate treatment. Approximately one half of all patients die within the first 2 to 3 years of symptom onset. In addition, the age of the patients presenting for aortic valve replacement (AVR) is increased along with the demographic changes. The Society of Thoracic Surgeons (STS) database shows that the number of patients older than 80 years has increased from 12% to 24% during the past 20 years. At the same time, the percentage of candidates requiring AVR as well as concomitant coronary bypass surgery has increased from 5% to 25%. Surgical AVR continues to be the criterion standard for treatment of aortic stenosis, improving survival and quality of life. Recent advances in prosthetic valve technology, such as transcatheter AVR, have expanded the indication for AVR to the extreme high-risk population, and the most recent surgical innovation, rapid deployment AVR, provides an additional tool to the surgeons’ armamentarium. PMID:26918310

  1. Including aortic valve morphology in computational fluid dynamics simulations: initial findings and application to aortic coarctation.

    PubMed

    Wendell, David C; Samyn, Margaret M; Cava, Joseph R; Ellwein, Laura M; Krolikowski, Mary M; Gandy, Kimberly L; Pelech, Andrew N; Shadden, Shawn C; LaDisa, John F

    2013-06-01

    Computational fluid dynamics (CFD) simulations quantifying thoracic aortic flow patterns have not included disturbances from the aortic valve (AoV). 80% of patients with aortic coarctation (CoA) have a bicuspid aortic valve (BAV) which may cause adverse flow patterns contributing to morbidity. Our objectives were to develop a method to account for the AoV in CFD simulations, and quantify its impact on local hemodynamics. The method developed facilitates segmentation of the AoV, spatiotemporal interpolation of segments, and anatomic positioning of segments at the CFD model inlet. The AoV was included in CFD model examples of a normal (tricuspid AoV) and a post-surgical CoA patient (BAV). Velocity, turbulent kinetic energy (TKE), time-averaged wall shear stress (TAWSS), and oscillatory shear index (OSI) results were compared to equivalent simulations using a plug inlet profile. The plug inlet greatly underestimated TKE for both examples. TAWSS differences extended throughout the thoracic aorta for the CoA BAV, but were limited to the arch for the normal example. OSI differences existed mainly in the ascending aorta for both cases. The impact of AoV can now be included with CFD simulations to identify regions of deleterious hemodynamics thereby advancing simulations of the thoracic aorta one step closer to reality. PMID:22917990

  2. Platypnea-Orthodeoxia Syndrome after Transcatheter Aortic Valve Implantation

    PubMed Central

    Garot, Jerome; Neylon, Antoinette; Sawaya, Fadi J.; Lefèvre, Thierry

    2016-01-01

    Progressive dyspnea and hypoxaemia in the subacute phase after transcatheter aortic valve implantation (TAVI) are uncommon and warrant immediate assessment of valve and prosthesis leaflet function to exclude thrombosis, as well as investigation for other causes related to the procedure, such as left ventricular dysfunction, pulmonary embolism, and respiratory sepsis. In this case, we report the observation of a patient presenting two weeks after TAVI with arterial hypoxaemia in an upright position, relieved by lying flat, and coupled with an intracardiac shunt detected on echocardiography in the absence of pulmonary hypertension, raising the suspicion of Platypnea-Orthodeoxia Syndrome (POS). Invasive intracardiac haemodynamic assessment showed a significant right-to-left shunt (Qp/Qs = 0.74), which confirmed the diagnosis, with subsequent closure of the intracardiac defect resulting in immediate relief of symptoms and hypoxaemia. To our knowledge, this is the first reported case of an interatrial defect and shunt causing Platypnea-Orthodeoxia Syndrome after transcatheter aortic valve implantation, resolved by percutaneous device closure. PMID:27610250

  3. Platypnea-Orthodeoxia Syndrome after Transcatheter Aortic Valve Implantation.

    PubMed

    Roy, Andrew K; Garot, Jerome; Neylon, Antoinette; Spaziano, Marco; Sawaya, Fadi J; Lefèvre, Thierry

    2016-01-01

    Progressive dyspnea and hypoxaemia in the subacute phase after transcatheter aortic valve implantation (TAVI) are uncommon and warrant immediate assessment of valve and prosthesis leaflet function to exclude thrombosis, as well as investigation for other causes related to the procedure, such as left ventricular dysfunction, pulmonary embolism, and respiratory sepsis. In this case, we report the observation of a patient presenting two weeks after TAVI with arterial hypoxaemia in an upright position, relieved by lying flat, and coupled with an intracardiac shunt detected on echocardiography in the absence of pulmonary hypertension, raising the suspicion of Platypnea-Orthodeoxia Syndrome (POS). Invasive intracardiac haemodynamic assessment showed a significant right-to-left shunt (Qp/Qs = 0.74), which confirmed the diagnosis, with subsequent closure of the intracardiac defect resulting in immediate relief of symptoms and hypoxaemia. To our knowledge, this is the first reported case of an interatrial defect and shunt causing Platypnea-Orthodeoxia Syndrome after transcatheter aortic valve implantation, resolved by percutaneous device closure. PMID:27610250

  4. In vitro Models of Aortic Valve Calcification: Solidifying a System

    PubMed Central

    Bowler, Meghan A.; Merryman, W. David

    2014-01-01

    Calcific aortic valve disease (CAVD) affects 25% of people over 65, and the late-stage stenotic state can only be treated with total valve replacement, requiring 85,000 surgeries annually in the US alone [1]. As CAVD is an age-related disease, many of the affected patients are unable to undergo the open-chest surgery that is its only current cure. This challenge motivates the elucidation of the mechanisms involved in calcification, with the eventual goal of alternative preventative and therapeutic strategies. There is no sufficient animal model of CAVD, so we turn to potential in vitro models. In general, in vitro models have the advantages of shortened experiment time and better control over multiple variables compared to in vivo models. As with all models, the hypothesis being tested dictates the most important characteristics of the in vivo physiology to recapitulate. Here, we collate the relevant pieces of designing and evaluating aortic valve calcification so that investigators can more effectively draw significant conclusions from their results. PMID:25249188

  5. Histopathology of aortic complications in bicuspid aortic valve versus Marfan syndrome: relevance for therapy?

    PubMed

    Grewal, Nimrat; Franken, Romy; Mulder, Barbara J M; Goumans, Marie-José; Lindeman, Johannes H N; Jongbloed, Monique R M; DeRuiter, Marco C; Klautz, Robert J M; Bogers, Ad J J C; Poelmann, Robert E; Groot, Adriana C Gittenberger-de

    2016-05-01

    Patients with bicuspid aortic valve (BAV) and patients with Marfan syndrome (MFS) are more prone to develop aortic dilation and dissection compared to persons with a tricuspid aortic valve (TAV). To elucidate potential common and distinct pathways of clinical relevance, we compared the histopathological substrates of aortopathy. Ascending aortic wall biopsies were divided in five groups: BAV (n = 36) and TAV (n = 23) without and with dilation and non-dilated MFS (n = 8). General histologic features, apoptosis, the expression of markers for vascular smooth muscle cell (VSMC) maturation, markers predictive for ascending aortic dilation in BAV, and expression of fibrillin-1 were investigated. Both MFS and BAV showed an altered distribution and decreased fibrillin-1 expression in the aorta and a significantly lower level of differentiated VSMC markers. Interestingly, markers predictive for aortic dilation in BAV were not expressed in the MFS aorta. The aorta in MFS was similar to the aorta in dilated TAV with regard to the presence of medial degeneration and apoptosis, while other markers for degeneration and aging like inflammation and progerin expression were low in MFS, comparable to BAV. Both MFS and BAV aortas have immature VSMCs, while MFS and TAV patients have a similar increased rate of medial degeneration. However, the mechanism leading to apoptosis is expected to be different, being fibrillin-1 mutation induced increased angiotensin-receptor-pathway signaling in MFS and cardiovascular aging and increased progerin in TAV. Our findings could explain why angiotensin inhibition is successful in MFS and less effective in TAV and BAV patients. PMID:26129868

  6. Myocardial injury associated with transcatheter aortic valve implantation (TAVI).

    PubMed

    Kim, Won-Keun; Liebetrau, Christoph; van Linden, Arnaud; Blumenstein, Johannes; Gaede, Luise; Hamm, Christian W; Walther, Thomas; Möllmann, Helge

    2016-05-01

    Transcatheter aortic valve implantation (TAVI) has emerged as an important treatment option for elderly patients with symptomatic aortic stenosis whose risk is too high or prohibitive for conventional surgery. Despite notable progress during the past decade, continuous efforts directed at further improvement of procedural safety and performance are required, especially considering expanding indications for interventional treatment options among lower-risk populations. One issue that needs to be addressed is myocardial damage, which can frequently be observed after TAVI and has been linked to worse prognosis. Yet, knowledge concerning the underlying mechanisms and clinical impact remains scarce, and further investigation in this field is warranted. In this review, we provide a contemporary summary of the types of myocardial injury associated with TAVI, including access-related injury, mechanical trauma and ischemia, the role of myocardial biomarkers, and the impact on left ventricular function, with emphasis on potential mechanisms and clinical implications. PMID:26670909

  7. Coronary artery bypass grafting associated to aortic valve replacement in the elderly: survival and quality of life

    PubMed Central

    2012-01-01

    Myocardial ischemia is often associated to aortic valve stenosis in the elderly. Aim of this study was to evaluate the impact on survival and quality of life of CABG associated to aortic valve replacement in the septuagenarians and octogenarians. Between January 1991 and January 2010, 520 patients ageing > 70 years underwent aortic valve replacement with a mechanical prosthesis in two Institutions. They were divided into 2 groups: Group A included 406 patients undergoing isolated aortic valve replacement; Group B 114 patients receiving aortic valve replacement and CABG. A comparative analysis of long-term survival and quality of life (SF-36 test) was performed. Mean age was 74.2 ± 3.6 years (74.3 ± 3.6 in Group A, 74 ± 3.3 in Group B; p = 0.33). Hospital mortality was 9.5% (46 patients). Twenty-nine (7.8%) in Group A and 17 in Group B (15.2%)(p = 0.019). Actuarial survival was 88.5% ± 0.015 at 1 year, 81.9% ± 0.02 at 5 years, 76.6% ± 0.032 at 10 and 57.3 ± 0.1 at 15 years. Ten-year survival was 77% ± 0.034 in Group A and 77.8% ± 0.045 in Group B (p = 0.2). Multivariate analysis did not reveal associated CABG as a predictor of long term mortality. The scores obtained in the SF-36 test were similar in the two groups and significantly higher than those of the general population matched for country, age and sex (p < 0.001 in all domains). Associated CABG determines a significant increase of hospital mortality in the elderly undergoing aortic valve replacement. Survivors did not show differences in long-term outcome and quality of life according to the presence of associated CABG. PMID:22309837

  8. Off-Pump Coronary Artery Bypass Grafting and Transaortic Transcatheter Aortic Valve Replacement.

    PubMed

    Dellis, Sophia L; Akujuo, Adanna C; Bennett, Edward V; Britton, Lewis W

    2016-07-01

    We sought to demonstrate the effectiveness of off-pump coronary artery bypass grafting and transcatheter aortic valve replacement in two patients with porcelain aortas and lesions that could not be optimally treated with percutaneous coronary intervention. Patients with aortic stenosis and coronary artery disease who are too high-risk for conventional surgical aortic valve replacement and coronary artery bypass grafting due to comorbidities and porcelain aorta, and who do not have the appropriate anatomy for percutaneous coronary intervention should be considered for concomitant transcatheter aortic valve replacement and off-pump coronary artery bypass grafting. doi: 10.1111/jocs.12762 (J Card Surg 2016;31:435-438). PMID:27196956

  9. Echocardiographic and electron beam tomographic assessment of stenosis in patients with aortic valve disease: gradient versus valve area

    PubMed Central

    Piers, L.H.; Dikkers, R.; Tio, R.A.; van den Berg, M.P.; Willems, T.P.; Oudkerk, M.; Zijlstra, F.

    2006-01-01

    Background Transthoracic echocardiography (TTE) is routinely used to evaluate aortic valve stenosis. However, it does not give reliable results in every patient. There is growing interest in electron-beam tomography (EBT) as a noninvasive cardiac imaging technique. The usefulness of EBT to evaluate aortic stenosis has yet to be evaluated. Aim To compare EBT with TTE in assessing severity of aortic stenosis. Methods In total 47 patients (18 females, 29 males) underwent a contrast-enhanced EBT scan and TTE within 6±20 days. The calcium score of the aortic valve was determined and the aortic valve area (AVA) was measured by planimetry. A complete TTE study, during which the peak pressure gradient across the aortic valve was measured, was performed in all patients by an experienced sonographer. Results There was a significant correlation between AVA assessed by EBT and peak pressure gradient (r=-0.38, p=0.009). The calcium score of the aortic valve assessed by EBT correlated with peak pressure gradient (r=0.48, p=0.001). Conclusion EBT is a useful noninvasive method to evaluate the severity of aortic stenosis. It holds the possibility of assessing the AVA as well as quantification of the degree of calcification. ImagesFigure 1 PMID:25696558

  10. Exophytic Atheroma Mimicking Papillary Fibroelastoma Adjacent to the Aortic Valve.

    PubMed

    Cho, Tomoki; Tokunaga, Shigehiko; Yasuda, Shota; Izubuchi, Ryo; Masuda, Munetaka

    2015-09-01

    Follow-up echocardiography in a 69-year-old man with alcoholic cardiomyopathy showed a mass above the aortic valve near the left coronary ostium. Transesophageal echocardiography and computed tomography suggested a papillary fibroelastoma with a high risk of embolism. At operation we found an exophytic atheroma adjacent to the left coronary artery orifice. The atheroma was removed, and the patient made an uneventful recovery. We describe this very rare case of an exophytic atheroma mimicking a papillary fibroelastoma situated at the left coronary orifice. PMID:26354633

  11. Combined aortic and mitral valve replacement in an adult with Scheie's disease.

    PubMed

    Butman, S M; Karl, L; Copeland, J G

    1989-07-01

    Mitral, aortic, and coronary arterial disease have been described in the various mucopolysaccharidoses. We report the first successful combined aortic and mitral valve replacement in an adult female patient with severe aortic and mitral stenosis due to Scheie's syndrome, a mucopolysaccharide storage disease. Both annulae were of sufficient integrity for good prosthetic placement, and the patient had an uneventful postoperative recovery. PMID:2500310

  12. In-Graft Endovascular Stenting Repair for Supravalvular Stenosis From Aortic Rupture After Balloon-Expanding Transcatheter Aortic Valve Implantation.

    PubMed

    Furukawa, Nobuyuki; Scholtz, Werner; Haas, Nikolaus; Ensminger, Stephan; Gummert, Jan; Börgermann, Jochen

    2015-01-01

    An 81-year-old man with high-grade aortic valve stenosis and status post-coronary artery bypass grafting and supracoronary replacement of the ascending aorta was referred for transcatheter aortic valve implantation. He was in New York Heart Association class III and had dyspnea. After appropriate screening, we implanted a 29-mm SAPIEN XT valve (Edwards Lifesciences, Irvine, CA USA) through a transapical approach because of severe peripheral arterial occlusive disease. Postinterventional aortography revealed correct positioning and function of the valve and free coronary ostia but contrast extravasation in the vicinity of the interposed vascular prosthesis, resulting in severe luminal narrowing. We chose to manage the stenosis with an endovascular stent. After stenting, extravascular compression was markedly reduced, and the pressure gradient disappeared. The patient was discharged home on the 20th postoperative day. Three months later, computed tomography depicted correct positioning of both grafts. The patient's general health is good, and he is now in New York Heart Association class II. This case illustrates a complication of transcatheter aortic valve implantation specific for patients with an ascending aortic graft. Although stenting may be a good solution, as depicted by this case, self-expanding transcatheter aortic valves should be preferred in patients with ascending aortic grafts to avoid the described complication. PMID:26355692

  13. A Quadricuspid Aortic Valve as Seen by Cardiac Magnetic Resonance Imaging.

    PubMed

    Jones, James; Liotta, Robert; Hood, Maureen; Bustamante, Alexander

    2016-09-01

    We report a case of a 35-year-old active duty male with a rare quadricuspid aortic valve identified via transthoracic echocardiography following the detection of an incidental grade I/VI diastolic murmur. Further characterization of the anatomical findings and aortic valve flow dynamics were evaluated with cardiac magnetic resonance imaging. Accurate assessment of the various valve morphologies is essential, as it guides surgical treatment options to correct the defect. Our case highlights the complimentary role of cardiac magnetic resonance imaging in defining the anatomy and functional consequences of a quadricuspid aortic valve. PMID:27612379

  14. Quadricuspid aortic valve by cardiac magnetic resonance imaging: a case report and review of the literature.

    PubMed

    Khan, Shamruz Khan Akerem; Tamin, Syahidah Syed; Araoz, Philip A

    2011-01-01

    Quadricuspid aortic valve (QAV) is a rare congenital cardiac entity. The recognition of QAV has clinical significance as it causes aortic valve dysfunction, commonly aortic regurgitation, and is often associated with other congenital cardiac abnormalities. We showed the important role played by cardiac magnetic resonance imaging in detecting QAV and review the available literature to explain its incidence, diagnosis, classifications, embryology, correlation between morphology of the QAV and its function, associated conditions, and management. PMID:21926862

  15. Dynamic heart phantom with functional mitral and aortic valves

    NASA Astrophysics Data System (ADS)

    Vannelli, Claire; Moore, John; McLeod, Jonathan; Ceh, Dennis; Peters, Terry

    2015-03-01

    Cardiac valvular stenosis, prolapse and regurgitation are increasingly common conditions, particularly in an elderly population with limited potential for on-pump cardiac surgery. NeoChord©, MitraClipand numerous stent-based transcatheter aortic valve implantation (TAVI) devices provide an alternative to intrusive cardiac operations; performed while the heart is beating, these procedures require surgeons and cardiologists to learn new image-guidance based techniques. Developing these visual aids and protocols is a challenging task that benefits from sophisticated simulators. Existing models lack features needed to simulate off-pump valvular procedures: functional, dynamic valves, apical and vascular access, and user flexibility for different activation patterns such as variable heart rates and rapid pacing. We present a left ventricle phantom with these characteristics. The phantom can be used to simulate valvular repair and replacement procedures with magnetic tracking, augmented reality, fluoroscopy and ultrasound guidance. This tool serves as a platform to develop image-guidance and image processing techniques required for a range of minimally invasive cardiac interventions. The phantom mimics in vivo mitral and aortic valve motion, permitting realistic ultrasound images of these components to be acquired. It also has a physiological realistic left ventricular ejection fraction of 50%. Given its realistic imaging properties and non-biodegradable composition—silicone for tissue, water for blood—the system promises to reduce the number of animal trials required to develop image guidance applications for valvular repair and replacement. The phantom has been used in validation studies for both TAVI image-guidance techniques1, and image-based mitral valve tracking algorithms2.

  16. Biaxial Creep Resistance and Structural Remodeling of the Aortic and Mitral Valves in Pregnancy.

    PubMed

    Pierlot, Caitlin M; Moeller, Andrew D; Lee, J Michael; Wells, Sarah M

    2015-08-01

    Pregnancy produces rapid, dramatic volume-overload changes to the maternal circulation. This paper examines pregnancy-induced structural-mechanical changes in bovine aortic and mitral heart valve leaflets. Valve leaflets were harvested from non-pregnant heifers and pregnant cows. Dimensions, biaxial extensibility and creep resistance were assessed and related to changes in the collagen network: histological leaflet and anatomic layer thicknesses plus collagen crimp, and biochemical collagen content. Collagen stability and crosslinking were assessed thermomechanically. Pregnancy altered both aortic and mitral valve leaflets. Both valves demonstrated biphasic changes in leaflet stretch, decreasing in early pregnancy and recovering by late pregnancy. Creep in leaflets from both valves was minimal and decreased even further with pregnancy in the mitral valve. There were valve-specific changes in preconditioning areal extension with pregnancy: increasing in the aortic valve and decreasing in the mitral valve. Leaflet area increased dramatically (84% aortic, 56% mitral), with thickening mainly in the fibrosa, accompanied by increases in collagen content (8% aortic, 16% mitral): together suggesting synthesis of new collagen. Collagen crimp was almost completely lost in pregnancy, with the denaturation temperature decreased by approximately 2 °C. Mature and total crosslinking increased, curiously without a significant increase in immature crosslinking. Mature aortic and mitral heart valve leaflets in the maternal cardiovascular system remodel substantially and similarly-despite their different embryological origins. PMID:25564325

  17. Clinical comparison of St. Jude and porcine aortic valve prostheses.

    PubMed

    Douglas, P S; Hirshfeld, J W; Edie, R N; Harken, A H; Stephenson, L W; Edmunds, L H

    1985-09-01

    One hundred eighty-seven consecutive patients who had aortic valve replacement with either a St. Jude or porcine heterograft prosthesis were studied prospectively. The two groups were similar with respect to 67 clinical and operative factors, which allowed comparison of valve performance as an independent variable. Total follow-up was 6162 patient-months (mean 32 months, range 23 to 62, 99% complete). There were no statistical differences in symptomatic improvement or mortality by life-table analysis. Valve-related complications expressed as percent per patient-year included: reoperation, 0.6 St. Jude and 1.2 porcine; endocarditis, 1.1 and 0.9; regurgitant murmur, 3.4 and 2.7; hemolysis, 2.8 and 0.0; thromboembolism, 2.8 and 1.5 (all not significant); and hemorrhage, 7.9 and 2.4 (p less than .005). Anticoagulant-related bleeding was the only significant difference between the two valves in morbidity and mortality 32 to 34 months after operation. PMID:4028357

  18. Transcatheter Aortic Valve Replacement in Women Versus Men (from the US CoreValve Trials).

    PubMed

    Forrest, John K; Adams, David H; Popma, Jeffrey J; Reardon, Michael J; Deeb, G Michael; Yakubov, Steven J; Hermiller, James B; Huang, Jian; Skelding, Kimberly A; Lansky, Alexandra

    2016-08-01

    Treatment for severe symptomatic aortic stenosis has changed significantly in recent years due to advances in transcatheter aortic valve replacement (TAVR). Recent studies with the CoreValve prosthesis have demonstrated superior results compared with surgical aortic valve replacement in patients at increased risk for surgery, but there are limited data on gender-related differences in patient characteristics and outcomes with this device. We compared baseline characteristics and clinical outcomes in women and men undergoing TAVR with the CoreValve prosthesis. A total of 3,687 patients (1,708 women and 1,979 men) were included. At baseline, women tended to be slightly older and to have increased frailty, but they had fewer cardiac co-morbidities, higher left ventricular systolic function, less coronary artery disease, and fewer previous strokes. All-cause mortality was 5.9% for women and 5.8% for men at 30 days (p = 0.87) and 24.1% and 21.3%, respectively, at 1 year (p = 0.08). The incidence of stroke was 5.7% in women and 4.0% in men at 30 days (p = 0.02) and 9.3% and 7.7%, respectively, at 1 year (p = 0.05). Women had a higher incidence of bleeding, including more life-threatening bleeds, and a greater incidence of major vascular complications than men at 30 days. Device success was achieved in 86.9% of women and 86.1% of men (p = 0.50). In conclusion, although there were significant baseline differences and procedure-related complications between women and men undergoing TAVR with the CoreValve prosthesis, this analysis found no significant difference in 30-day or 1-year mortality. PMID:27346591

  19. Technical Approach Determines Inflammatory Response after Surgical and Transcatheter Aortic Valve Replacement

    PubMed Central

    Erdoes, Gabor; Lippuner, Christoph; Kocsis, Istvan; Schiff, Marcel; Stucki, Monika; Carrel, Thierry; Windecker, Stephan; Eberle, Balthasar; Stueber, Frank; Book, Malte

    2015-01-01

    Objective To investigate the periprocedural inflammatory response in patients with isolated aortic valve stenosis undergoing surgical aortic valve replacement (SAVR) or transcatheter aortic valve implantation (TAVI) with different technical approaches. Material and Methods Patients were prospectively allocated to one of the following treatments: SAVR using conventional extracorporeal circulation (CECC, n = 47) or minimized extracorporeal circulation (MECC, n = 15), or TAVI using either transapical (TA, n = 15) or transfemoral (TF, n = 24) access. Exclusion criteria included infection, pre-procedural immunosuppressive or antibiotic drug therapy and emergency indications. We investigated interleukin (IL)-6, IL-8, IL-10, human leukocyte antigen (HLA-DR), white blood cell count, high-sensitivity C-reactive protein (hs-CRP) and soluble L-selectin (sCD62L) levels before the procedure and at 4, 24, and 48 h after aortic valve replacement. Data are presented for group interaction (p-values for inter-group comparison) as determined by the Greenhouse-Geisser correction. Results SAVR on CECC was associated with the highest levels of IL-8 and hs-CRP (p<0.017, and 0.007, respectively). SAVR on MECC showed the highest descent in levels of HLA-DR and sCD62L (both p<0.001) in the perioperative period. TA-TAVI showed increased intraprocedural concentration and the highest peak of IL-6 (p = 0.017). Significantly smaller changes in the inflammatory markers were observed in TF-TAVI. Conclusion Surgical and interventional approaches to aortic valve replacement result in inflammatory modulation which differs according to the invasiveness of the procedure. As expected, extracorporeal circulation is associated with the most marked pro-inflammatory activation, whereas TF-TAVI emerges as the approach with the most attenuated inflammatory response. Factors such as the pre-treatment patient condition and the extent of myocardial injury also significantly affect inflammatory biomarker patterns

  20. The power of disruptive technological innovation: Transcatheter aortic valve implantation.

    PubMed

    Berlin, David B; Davidson, Michael J; Schoen, Frederick J

    2015-11-01

    We sought to evaluate the principles of disruptive innovation, defined as technology innovation that fundamentally shifts performance and utility metrics, as applied to transcatheter aortic valve implantation (TAVI). In particular, we considered implantation procedure, device design, cost, and patient population. Generally cheaper and lower performing, classical disruptive innovations are first commercialized in insignificant markets, promise lower margins, and often parasitize existing usage, representing unattractive investments for established market participants. However, despite presently high unit cost, TAVI is less invasive, treats a "new," generally high risk, patient population, and is generally done by a multidisciplinary integrated heart team. Moreover, at least in the short-term TAVI has not been lower-performing than open surgical aortic valve replacement in high-risk patients. We conclude that TAVI extends the paradigm of disruptive innovation and represents an attractive commercial opportunity space. Moreover, should the long-term performance and durability of TAVI approach that of conventional prostheses, TAVI will be an increasingly attractive commercial opportunity. PMID:25545639

  1. Risk profile and outcomes of aortic valve replacement in octogenarians

    PubMed Central

    Kesavan, Sujatha; Iqbal, Aamer; Khan, Yusra; Hutter, Jonathan; Pike, Katie; Rogers, Chris; Turner, Mark; Townsend, Mandie; Baumbach, Andreas

    2011-01-01

    AIM: To investigate the patient characteristics, relationship between the Logistic EuroSCORE (LES) and the observed outcomes in octogenarians who underwent surgical aortic valve replacement (AVR). METHODS: Two hundred and seventy three octogenarians underwent AVR between 1996 and 2008 at Bristol Royal Infirmary. Demographics, acute outcomes, length of hospital stay and mortality were obtained. The LES was calculated to characterize the predicted operative risk. Two groups were defined: LES ≥ 15 (n = 80) and LES < 15 (n = 193). RESULTS: In patients with LES ≥ 15, 30 d mortality was 14% (95% CI: 7%-23%) compared with 4% (95% CI: 2%-8%) in the LES < 15 group (P < 0.007). Despite the increase in number of operations from 1996 to 2008, the average LES did not change. Only 5% of patients had prior bypass surgery. The LES identified a low risk quartile of patients with a very low mortality (4%, n = 8, P < 0.007) at 30 d. The overall surgical results for octogenarians were excellent. The low risk group had an excellent outcome and the high risk group had a poor outcome after surgical AVR. CONCLUSION: It may be better treated with transcatheter aortic valve implantation. PMID:22125671

  2. Role of Glutaraldehyde in Calcification of Porcine Aortic Valve Fibroblasts

    PubMed Central

    Kim, Kookmin M.; Herrera, Guillermo A.; Battarbee, Harold D.

    1999-01-01

    Glutaraldehyde-treated porcine aortic valve xenografts frequently fail due to calcification. Calcification in the prostheses begins intracellularly. In a previous study, various types of cell injury to canine valvular fibroblasts, including glutaraldehyde treatment, led to calcification. An influx of extracellular Ca2+ into the phosphate-rich cytosol was theorized to be the mechanism of calcification. To test the Ca2+ influx theory, cytosolic Ca2+ and Pi concentrations were assessed in glutaraldehyde-treated porcine aortic valve fibroblasts, and their relationship to a subsequent calcification was studied. Glutaraldehyde caused an immediate and sustained massive cytosolic Ca2+ increase that was dose dependent and a several-fold increase in Pi. Calcification of cells followed within a week. The earliest calcification was observed in blebs formed on glutaraldehyde-treated cells. Live control cells or cells fixed with glutaraldehyde in Ca2+-free solution did not calcify under the same conditions. Concomitant increases in Ca2+ and Pi in glutaraldehyde-treated cells appear to underlie the mechanism of calcification, and the presence of extracellular Ca2+ during glutaraldehyde fixation promotes calcification. PMID:10079262

  3. Elevated transaortic valvular gradients after combined aortic valve and mitral valve replacement: an intraoperative dilemma.

    PubMed

    Essandoh, Michael; Portillo, Juan; Zuleta-Alarcon, Alix; Castellon-Larios, Karina; Otey, Andrew; Sai-Sudhakar, Chittoor B

    2015-03-01

    High transaortic valvular gradients, after combined aortic valve and mitral valve replacement, require prompt intraoperative diagnosis and appropriate management. The presence of high transaortic valvular gradients after cardiopulmonary bypass, in this setting, can be secondary to the following conditions: prosthesis dysfunction, left ventricular outflow tract obstruction, supravalvular obstruction, prosthesis-patient mismatch, hyperkinetic left ventricle from administration of inotropes, left ventricular intracavitary gradients, pressure recovery phenomenon, and increased transvalvular blood flow resulting from hyperdynamic circulation or anemia. Transesophageal echocardiography is an extremely useful tool for timely diagnosis and treatment of this complication. We describe a case of a critically ill patient with endocarditis and acute lung injury, who presented for combined aortic valve and mitral valve replacement. Transesophageal echocardiographic assessment, post-cardiopulmonary bypass, revealed high transaortic valvular gradients due to encroachment of the mitral prosthesis strut on the left ventricular outflow tract, which was compounded by a small, hypertrophied, and hyperkinetic left ventricle. Discontinuation of inotropic support, administration of fluids, phenylephrine, and esmolol led to resolution of the high gradients and prevented further surgery. PMID:25549635

  4. Simultaneous transapical aortic and mitral valve-in-valve implantation for double prostheses dysfunction: case report and technical insights.

    PubMed

    D'Onofrio, Augusto; Zucchetta, Fabio; Gerosa, Gino

    2014-09-01

    Transcatheter "Valve-in-Valve" implantation (ViV) has shown promising results in high-risk patients suffering from structural valve deterioration (SVD) of a previously implanted heart valve bioprosthesis. We present a case of a 68-year-old woman with a history of three previous cardiac operations on the aortic and mitral valve. At the time of admission she was severely symptomatic due to a simultaneous SVD of a 23 mm aortic and of a 29 mm mitral St. Jude Biocor bioprosthesis. Because of the history of several cardiac operations and to her comorbidities, the patient was considered with an extremely high surgical risk profile and was therefore scheduled for double concomitant mitral and aortic ViV. Through a trans-apical approach, the patient underwent 23 and 29 mm Edwards Sapien XT implantation in the aortic and mitral bioprosthesis, respectively. The procedure was uneventful as well as the following hospital stay. At 6-months follow-up the patient is in NYHA class I. Echocardiography shows that the aortic bioprosthesis has no leak and the mean gradient is 20 mm Hg while the mitral valve has mild leak and maximum and mean gradients are 21 and 10 mm Hg, respectively. The three main technical aspects that should be carefully considered in double concomitant ViV are: sequence of valve deployment (whether to implant the mitral or the aortic valve first), choice of access and valve sizing. In conclusion, double simultaneous trans-apical mitral and aortic ViV is technically feasible. © 2014 Wiley Periodicals, Inc. PMID:24677811

  5. Assessment of the influence of the compliant aortic root on aortic valve mechanics by means of a geometrical model.

    PubMed

    Redaelli, A; Di Martino, E; Gamba, A; Procopio, A M; Fumero, R

    1997-12-01

    In recent years several researchers have suggested that the changes in the geometry and angular dimensions of the aortic root which occur during the cardiac cycle are functional to the optimisation of aortic valve function, both in terms of diminishing leaflet stresses and of fluid-dynamic behaviour. The paper presents an analytical parametric model of the aortic valve which includes the aortic root movement. The indexes used to evaluate the valve behaviour are the circumferential membrane stress and the stress at the free edge of the leaflet, the index of bending strain, the bending of the leaflet at the line attachment in the radial and circumferential directions and the shape of the conduit formed by the leaflets during systole. In order to evaluate the role of geometric changes in valve performance, two control cases were considered, with different reference geometric configuration, where the movement of the aortic root was ignored. The results obtained appear consistent with physiological data, especially with regard to the late diastolic phase and the early ejection phase, and put in evidence the role of the aortic root movement in the improvement of valve behaviour. PMID:9450254

  6. Infective endocarditis of the aortic valve in a Border collie dog with patent ductus arteriosus

    PubMed Central

    AOKI, Takuma; SUNAHARA, Hiroshi; SUGIMOTO, Keisuke; ITO, Tetsuro; KANAI, Eiichi; FUJII, Yoko

    2014-01-01

    Infective endocarditis (IE) in dogs with cardiac shunts has not been reported previously. However, we encountered a dog with concurrent patent ductus arteriosus (PDA) and IE. The dog was a 1-year-old, 13.9-kg female Border collie and presented with anorexia, weight loss, pyrexia (40.4°C) and lameness. A continuous murmur with maximal intensity over the left heart base (Levine 5/6) was detected on auscultation. Echocardiography revealed a PDA and severe aortic stenosis (AS) caused by aortic-valve vegetative lesions. Corynebacterium spp. and Bacillus subtilis were isolated from blood cultures. The dog responded to aggressive antibiotic therapy, and the PDA was subsequently surgically corrected. After a series of treatments, the dog showed long-term improvement in clinical status. PMID:25391395

  7. Infective endocarditis of the aortic valve in a Border collie dog with patent ductus arteriosus.

    PubMed

    Aoki, Takuma; Sunahara, Hiroshi; Sugimoto, Keisuke; Ito, Tetsuro; Kanai, Eiichi; Fujii, Yoko

    2015-03-01

    Infective endocarditis (IE) in dogs with cardiac shunts has not been reported previously. However, we encountered a dog with concurrent patent ductus arteriosus (PDA) and IE. The dog was a 1-year-old, 13.9-kg female Border collie and presented with anorexia, weight loss, pyrexia (40.4 °C) and lameness. A continuous murmur with maximal intensity over the left heart base (Levine 5/6) was detected on auscultation. Echocardiography revealed a PDA and severe aortic stenosis (AS) caused by aortic-valve vegetative lesions. Corynebacterium spp. and Bacillus subtilis were isolated from blood cultures. The dog responded to aggressive antibiotic therapy, and the PDA was subsequently surgically corrected. After a series of treatments, the dog showed long-term improvement in clinical status. PMID:25391395

  8. Aortic Valve Repair: A Systematic Review and Meta-analysis of Published Literature

    PubMed Central

    Fok, Matthew; Shaw, Matthew; Sancho, Elena; Abello, David; Bashir, Mohamad

    2014-01-01

    Background: It is widely accepted that aortic valve disease is surgically managed with aortic valve replacement (AVR) using different available prostheses. The long-term survival, durability of the valve, and freedom from reoperation after AVR are well established in published literature. Over the past two decades, aortic valve repair (AVr) has evolved into an accepted surgical option for patients with aortic valve disease. We review and analyze the published literature on AVr. Methods: A systematic review of the current literature was performed through three electronic databases from inception to August 2013 to identify all relevant studies relating to aortic valve repair. Articles selected were chosen by two reviewers. Articles were excluded if they contained a pediatric population or if the patient number was less than 50. Results: Twenty-four studies conformed to the inclusion criteria for inclusion in the systematic review. In total, 4986 patients underwent aortic valve repair. 7 studies represented bicuspid aortic valve (BAV) repair, 5 studies represented cusp prolapse, and 3 studies represented valve repair with root dilation or aneurysm. Overall weighted in-hospital mortality for all studies was low (1.46% ± 1.21). Preoperative aortic insufficiency (AI) ≥ 2+ did not correlate to reoperation for valve failure (Pearson's Rs 0.2705, P = 0.2585). AI at discharge was reported in 9 studies with a mean AI ≥ 2+ in 6.1% of patients. Weighted average percentage for valve reoperation following BAV repair was 10.23% ± 3.2. Weighted average reoperation following cusp prolapse repair was 3.83 ± 1.96. Weighted average reoperation in aortic valve sparing procedures with root replacement was 4.25% ± 2.46. Although there are limitations and complications of prosthetic valves, especially for younger individuals, there is ample published literature that confers strong evidence for AVR. On the contrary, aortic valve repair may be a useful option for selected patients

  9. Valve morphology effect in aortic coarctation flow using realistic silicon models and magnetic resonance imaging

    NASA Astrophysics Data System (ADS)

    Marrufo, Oscar; Solis-Najera, Sergio; Pibarot, Philippe; Kadem, Lyes; Kesharvarz-Motamed, Zahra; Rodriguez, Alfredo O.; Garcia, Julio

    2014-11-01

    Aortic valve morphology and phenotype may alter the aortic wall structure and its normal flow hemodynamics. However, the relationship between altered flow patterns and progression of wall pathology is often not fully understood in patients with aortic coartation and needs larger experimental work. In this study, we introduced a compatible experimental setup with magnetic resonance imaging (MRI) using a realistic aortic coarctation (AoCo) silicon model which can replicate physiological flow conditions (pressure, flow-wave, and systemic load). We evaluated the aortic valve hemodynamics of a normal tricuspid valve and a stenotic bicuspid valve using valve effective orifice area (EOA), peak and mean transvalvular pressure gradient (TPG). AoCo severity was assessed by the AoCo pressure gradient. For the tricuspid valve we obtained an EOA = 1.89 cm2, a peak TPG = 10 mmHg, and a mean TPG = 5 mmHg. For the bicuspid valve we obtained an EOA = 1.03 cm2, a peak TPG = 37 mmHg and a mean TPG = 13 mmHg. Furthermore, AoCo with tricuspid valve led to a peak AoCo pressure gradient (PG) = 11 mmHg and a mean PG = 5 mmHg. AoCo with bicuspid valve led to a peak PG = 6 mmHg and a mean PG = 3 mmHg. Aortic flow reattachment was more evident in presence of bicuspid valve and helical flow was present in all cases. This study showed that silicon prototyping in combination with MRI velocity measurements could successfully be used to assess hemodynamic effects of aortic valve morphology in aortic coarctation flow.

  10. [Aortic Valve Replacement after Balloon Valvuloplasty for Aortic Valve Stenosis in a Dialysis Patient with Cardiogenic Shock;Report of a Case].

    PubMed

    Takamatsu, Masanori; Hirotani, Takashi; Ohtsubo, Satoshi; Saito, Sumikatsu; Takeuchi, Shigeyuki; Hasegawa, Tasuku; Endo, Ayaka; Yamasaki, Yu; Hayashida, Kentaro

    2015-06-01

    A 67-year-old man on chronic hemodialysis was admitted with worsening congestive heart failure due to critical aortic stenosis. Echocardiography showed severe aortic stenosis with a valve area of 0.67 cm2 and an ejection fraction of 0.31. Cardiac catheterization revealed severe pulmonary hypertension with pulmonary artery pressures of 62/32 mmHg. In the middle of cardiac catheterization, the systolic pressure declined to 60 mmHg due to cardiogenic shock. Dopamine hydrochloride and dobutamine hydrochloride infusions were necessary to maintain a systolic pressure greater than 80 mmHg. Balloon aortic valvuloplasty was urgently performed. The patient's symptoms rapidly resolved except for angina on exertion. One month later, elective aortic valve replacement was performed. The postoperative course was uneventful and the he was discharged on the 60th postoperative day. A follow-up echocardiogram 6 months postoperatively revealed normal prosthetic valve function and an ejection fraction of 0.6. PMID:26066880

  11. Reversed L-type Upper Partial Sternotomy in Aortic Valve Replacement: an Initial Experience

    PubMed Central

    Karic, Alen

    2016-01-01

    Introduction: Degenerative aortic stenosis (AS) is the most frequent cause among aortic valve stenotic changes. Mini Sternotomy Aortic Valve Replacement is a replacement of aortic valve through upper partial sternotomy. Aim: The aim of this approach is to improve postoperative convalescence by leaving pleural spaces closed and do not compromise respiratory function, to decrease bleeding, and reduce post op ventilation time and ICU stay. All these advantages decrease cost during hospital stay by reducing ICU stay, respiration time, bleeding and using blood products, pain killers and shortening hospital stay. Esthetic effect is also considerable result of this method. Case report: This case report presents an initial experience with Reversed L-Type Upper Partial Sternotomy in Aortic Valve Replacement. The goal is to demonstrate that minimally invasive advanced cardiac surgery procedures can be performed in our country. PMID:27594754

  12. Increased transcript level of poly(ADP-ribose) polymerase (PARP-1) in human tricuspid compared with bicuspid aortic valves correlates with the stenosis severity

    SciTech Connect

    Nagy, Edit; Department of Cardiology, Karolinska University Hospital, Stockholm ; Caidahl, Kenneth; Department of Clinical Physiology, Karolinska University Hospital, Stockholm ; Franco-Cereceda, Anders; Department of Throracic Surgery, Karolinska University Hospital, Stockholm ; Baeck, Magnus; Department of Cardiology, Karolinska University Hospital, Stockholm

    2012-04-13

    Highlights: Black-Right-Pointing-Pointer Oxidative stress has been implicated in the pathomechanism of calcific aortic valve stenosis. Black-Right-Pointing-Pointer We assessed the transcript levels for PARP-1 (poly(ADP-ribose) polymerase), acts as a DNA damage nick sensor in stenotic valves. Black-Right-Pointing-Pointer Early stage of diseased tricuspid valves exhibited higher mRNA levels for PARP-1 compared to bicuspid valves. Black-Right-Pointing-Pointer The mRNA levels for PARP-1 inversely correlated with the clinical stenosis severity in tricuspid valves. Black-Right-Pointing-Pointer Our data demonstrated that DNA damage pathways might be associated with stenosis severity only in tricuspid valves. -- Abstract: Oxidative stress may contribute to the hemodynamic progression of aortic valve stenosis, and is associated with activation of the nuclear enzyme poly(ADP-ribose) polymerase (PARP) 1. The aim of the present study was to assess the transcriptional profile and the topological distribution of PARP-1 in human aortic valves, and its relation to the stenosis severity. Human stenotic aortic valves were obtained from 46 patients undergoing aortic valve replacement surgery and used for mRNA extraction followed by quantitative real-time PCR to correlate the PARP-1 expression levels with the non invasive hemodynamic parameters quantifying the stenosis severity. Primary isolated valvular interstitial cells (VICs) were used to explore the effects of cytokines and leukotriene C{sub 4} (LTC{sub 4}) on valvular PARP-1 expression. The thickened areas of stenotic valves with tricuspid morphology expressed significantly higher levels of PARP-1 mRNA compared with the corresponding part of bicuspid valves (0.501 vs 0.243, P = 0.01). Furthermore, the quantitative gene expression levels of PARP-1 were inversely correlated with the aortic valve area (AVA) (r = -0.46, P = 0.0469) and AVA indexed for body surface area (BSA) (r = -0.498; P = 0.0298) only in tricuspid aortic valves

  13. Potential drug targets for calcific aortic valve disease

    PubMed Central

    Hutcheson, Joshua D.; Aikawa, Elena; Merryman, W. David

    2014-01-01

    Calcific aortic valve disease (CAVD) is a major contributor to cardiovascular morbidity and mortality and, given its association with age, the prevalence of CAVD is expected to continue to rise as global life expectancy increases. No drug strategies currently exist to prevent or treat CAVD. Given that valve replacement is the only available clinical option, patients often cope with a deteriorating quality of life until diminished valve function demands intervention. The recognition that CAVD results from active cellular mechanisms suggests that the underlying pathways might be targeted to treat the condition. However, no such therapeutic strategy has been successfully developed to date. One hope was that drugs already used to treat vascular complications might also improve CAVD outcomes, but the mechanisms of CAVD progression and the desired therapeutic outcomes are often different from those of vascular diseases. We, therefore, discuss the benchmarks that must be met by a CAVD treatment approach, and highlight advances in the understanding of CAVD mechanisms to identify potential novel therapeutic targets. PMID:24445487

  14. Recurrent Rare Genomic Copy Number Variants and Bicuspid Aortic Valve Are Enriched in Early Onset Thoracic Aortic Aneurysms and Dissections

    PubMed Central

    Prakash, Siddharth; Kuang, Shao-Qing; Regalado, Ellen; Guo, Dongchuan; Milewicz, Dianna

    2016-01-01

    Thoracic Aortic Aneurysms and Dissections (TAAD) are a major cause of death in the United States. The spectrum of TAAD ranges from genetic disorders, such as Marfan syndrome, to sporadic isolated disease of unknown cause. We hypothesized that genomic copy number variants (CNVs) contribute causally to early onset TAAD (ETAAD). We conducted a genome-wide SNP array analysis of ETAAD patients of European descent who were enrolled in the National Registry of Genetically Triggered Thoracic Aortic Aneurysms and Cardiovascular Conditions (GenTAC). Genotyping was performed on the Illumina Omni-Express platform, using PennCNV, Nexus and CNVPartition for CNV detection. ETAAD patients (n = 108, 100% European American, 28% female, average age 20 years, 55% with bicuspid aortic valves) were compared to 7013 dbGAP controls without a history of vascular disease using downsampled Omni 2.5 data. For comparison, 805 sporadic TAAD patients with late onset aortic disease (STAAD cohort) and 192 affected probands from families with at least two affected relatives (FTAAD cohort) from our institution were screened for additional CNVs at these loci with SNP arrays. We identified 47 recurrent CNV regions in the ETAAD, FTAAD and STAAD groups that were absent or extremely rare in controls. Nine rare CNVs that were either very large (>1 Mb) or shared by ETAAD and STAAD or FTAAD patients were also identified. Four rare CNVs involved genes that cause arterial aneurysms when mutated. The largest and most prevalent of the recurrent CNVs were at Xq28 (two duplications and two deletions) and 17q25.1 (three duplications). The percentage of individuals harboring rare CNVs was significantly greater in the ETAAD cohort (32%) than in the FTAAD (23%) or STAAD (17%) cohorts. We identified multiple loci affected by rare CNVs in one-third of ETAAD patients, confirming the genetic heterogeneity of TAAD. Alterations of candidate genes at these loci may contribute to the pathogenesis of TAAD. PMID:27092555

  15. Retrograde Transcatheter Closure of Mitral Paravalvular Leak through a Mechanical Aortic Valve Prosthesis: 2 Successful Cases

    PubMed Central

    Zhou, Daxin; Pan, Wenzhi; Guan, Lihua; Qian, Juying

    2016-01-01

    The presence of a mechanical aortic valve prosthesis has been considered a contraindication to retrograde percutaneous closure of mitral paravalvular leaks, because passing a catheter through the mechanical aortic valve can affect the function of a mechanical valve and thereby lead to severe hemodynamic deterioration. We report what we believe are the first 2 cases of retrograde transcatheter closure of mitral paravalvular leaks through a mechanical aortic valve prosthesis without transseptal or transapical puncture. Our experience shows that retrograde transcatheter closure of mitral paravalvular leaks in this manner can be an optional approach for transcatheter closure of such leaks, especially when a transapical or transseptal puncture approach is not feasible. This technique might also be applied to other transcatheter procedures in which there is a need to pass a catheter through a mechanical aortic valve prosthesis. PMID:27127428

  16. Markov model for selection of aortic valve replacement versus transcatheter aortic valve implantation (without replacement) in high-risk patients.

    PubMed

    Gada, Hemal; Kapadia, Samir R; Tuzcu, E Murat; Svensson, Lars G; Marwick, Thomas H

    2012-05-01

    Comparisons between transcatheter aortic valve implantation without replacement (TAVI) and tissue aortic valve replacement (AVR) in clinical trials might not reflect the outcomes in standard clinical practice. This could have important implications for the relative cost-effectiveness of these alternatives for management of severe aortic stenosis in high-risk patients for whom surgery is an option. The mean and variance of risks, transition probabilities, utilities, and cost of TAVI, AVR, and medical management derived from observational studies were entered into a Markov model that examined the progression of patients between relevant health states. The outcomes and cost were derived from 10,000 simulations. Sensitivity analyses were based on variations in the likelihood of mortality, stroke, and other commonly observed outcomes. Both TAVI and AVR were cost-effective compared to medical management. In the reference case (age 80 years, the perioperative TAVI and AVR mortality was 6.9% vs 9.8%, and annual mortality was 21% vs 24%), the utility of TAVI was greater than that of AVR (1.78 vs 1.72 quality-adjusted life years) and the lifetime cost of TAVI exceeded that of AVR ($59,503 vs $56,339). The incremental cost-effectiveness ratio was $52,773/quality-adjusted life years. Threshold analyses showed that variation in the probabilities of perioperative and annual mortality after AVR and after TAVI and annual stroke after TAVI were important determinants of the favored strategy. Sensitivity analyses defined the thresholds at which TAVI or AVR was the preferred strategy with regard to health outcomes and cost. In conclusion, TAVI satisfies current metrics of cost-effectiveness relative to AVR and might provide net health benefits at acceptable cost for selected high-risk patients among whom AVR is the current procedure of choice. PMID:22335853

  17. Decreased platelet function in aortic valve stenosis: high shear platelet activation then inactivation.

    PubMed Central

    O'Brien, J. R.; Etherington, M. D.; Brant, J.; Watkins, J.

    1995-01-01

    OBJECTIVE--To elucidate the mechanism of the bleeding tendency observed in patients with aortic valve stenosis. DESIGN--A prospective study of high and low shear platelet function tests in vitro in normal controls compared with that in patients with severe aortic valve stenosis with a mean (SD) systolic gradient by Doppler of 75 (18) mm Hg before and at least 4 months after aortic valve replacement. SETTING--District general hospital. RESULTS--The patients showed reduced retention in the high shear platelet function tests. (a) Platelet retention in the filter test was 53.6 (12.6)% in patients with aortic valve stenosis and 84.8 (9.6)% in the controls (P < 0.001). (b) Retention in the glass bead column test was 49.8 (19.2) in the patients and 87.4 (8.7) in the controls (P < 0.001). (c) The standard bleeding time was longer in the patients (P < 0.06). Results of the high shear tests (a, b, and c) after aortic valve replacement were within the normal range. The platelet count was low but within the normal range before surgery and increased postoperatively (P < 0.01). There were no differences in the results of standard clotting tests, plasma and intraplatelet von Willebrand's factor, or in 15 platelet aggregation tests using five agonists between patients with aortic valve stenosis and controls. CONCLUSIONS--The high shear haemodynamics of aortic valve stenosis modify platelet function in vivo predisposing to a bleeding tendency. This abnormality of platelet function is detectable only in vitro using high shear tests. The abnormal function is reversed by aortic valve replacement. High shear forces in vitro activate and then inactivate platelets. By the same mechanisms aortic valve stenosis seems to lead to high shear damage in vivo, resulting in a clinically important bleeding tendency in some patients. PMID:8541170

  18. Comparative Transcriptome Analysis Reveals Substantial Tissue Specificity in Human Aortic Valve

    PubMed Central

    Wang, Jun; Wang, Ying; Gu, Weidong; Ni, Buqing; Sun, Haoliang; Yu, Tong; Gu, Wanjun; Chen, Liang; Shao, Yongfeng

    2016-01-01

    RNA sequencing (RNA-seq) has revolutionary roles in transcriptome identification and quantification of different types of tissues and cells in many organisms. Although numerous RNA-seq data derived from many types of human tissues and cell lines, little is known on the transcriptome repertoire of human aortic valve. In this study, we sequenced the total RNA prepared from two calcified human aortic valves and reported the whole transcriptome of human aortic valve. Integrating RNA-seq data of 13 human tissues from Human Body Map 2 Project, we constructed a transcriptome repertoire of human tissues, including 19,505 protein-coding genes and 4,948 long intergenic noncoding RNAs (lincRNAs). Among them, 263 lincRNAs were identified as novel noncoding transcripts in our data. By comparing transcriptome data among different human tissues, we observed substantial tissue specificity of RNA transcripts, both protein-coding genes and lincRNAs, in human aortic valve. Further analysis revealed that aortic valve-specific lincRNAs were more likely to be recently derived from repetitive elements in the primate lineage, but were less likely to be conserved at the nucleotide level. Expression profiling analysis showed significant lower expression levels of aortic valve-specific protein-coding genes and lincRNA genes, when compared with genes that were universally expressed in various tissues. Isoform-level expression analysis also showed that a majority of mRNA genes had a major isoform expressed in the human aortic valve. To our knowledge, this is the first comparative transcriptome analysis between human aortic valve and other human tissues. Our results are helpful to understand the transcriptome diversity of human tissues and the underlying mechanisms that drive tissue specificity of protein-coding genes and lincRNAs in human aortic valve. PMID:27493474

  19. Comparative Transcriptome Analysis Reveals Substantial Tissue Specificity in Human Aortic Valve.

    PubMed

    Wang, Jun; Wang, Ying; Gu, Weidong; Ni, Buqing; Sun, Haoliang; Yu, Tong; Gu, Wanjun; Chen, Liang; Shao, Yongfeng

    2016-01-01

    RNA sequencing (RNA-seq) has revolutionary roles in transcriptome identification and quantification of different types of tissues and cells in many organisms. Although numerous RNA-seq data derived from many types of human tissues and cell lines, little is known on the transcriptome repertoire of human aortic valve. In this study, we sequenced the total RNA prepared from two calcified human aortic valves and reported the whole transcriptome of human aortic valve. Integrating RNA-seq data of 13 human tissues from Human Body Map 2 Project, we constructed a transcriptome repertoire of human tissues, including 19,505 protein-coding genes and 4,948 long intergenic noncoding RNAs (lincRNAs). Among them, 263 lincRNAs were identified as novel noncoding transcripts in our data. By comparing transcriptome data among different human tissues, we observed substantial tissue specificity of RNA transcripts, both protein-coding genes and lincRNAs, in human aortic valve. Further analysis revealed that aortic valve-specific lincRNAs were more likely to be recently derived from repetitive elements in the primate lineage, but were less likely to be conserved at the nucleotide level. Expression profiling analysis showed significant lower expression levels of aortic valve-specific protein-coding genes and lincRNA genes, when compared with genes that were universally expressed in various tissues. Isoform-level expression analysis also showed that a majority of mRNA genes had a major isoform expressed in the human aortic valve. To our knowledge, this is the first comparative transcriptome analysis between human aortic valve and other human tissues. Our results are helpful to understand the transcriptome diversity of human tissues and the underlying mechanisms that drive tissue specificity of protein-coding genes and lincRNAs in human aortic valve. PMID:27493474

  20. SLM Produced Hermetically Sealed Isolation Valve

    NASA Technical Reports Server (NTRS)

    Richard, James A.

    2014-01-01

    Marshall Space Flight Center (MSFC) has developed a valve concept to replace traditional pyrotechnic driven isolation valves. This paper will describe the valve design and development process. The valve design uses a stem/wedge to support a disk inside the valve. That disk hermetically seals the pressurized fluids. A release mechanism holds the stem/wedge and a large spring in place. When required to open, a solenoid is energized and pulls the release mechanism allowing the spring to pull the stem/wedge away from the disk. Now the disk is unsupported and the pressure ruptures the disk allowing flow to the outlet of the valve. This paper will provide details of this design, describe the development testing, and show the results from the valve level tests performed. Also, a trade study is presented to show the advantages of this design to a conventional pyrotechnic based valve.

  1. SLM Produced Hermetically Sealed Isolation Valve

    NASA Technical Reports Server (NTRS)

    Richard, James

    2014-01-01

    Marshall Space Flight Center (MSFC) has developed a valve concept to replace traditional pyrotechnic-driven isolation valves. This paper will describe the valve design and development process. The valve design uses a stem/wedge to support a disk inside the valve. That disk hermetically seals the pressurized fluids. A release mechanism holds the stem/wedge and a large spring in place. When required to open, a solenoid is energized and pulls the release mechanism allowing the spring to pull the stem/wedge away from the disk. Now the disk is unsupported and the pressure ruptures the disk allowing flow to the outlet of the valve. This paper will provide details of this design, describe the development testing, and show the results from the valve level tests performed. Also, a trade study is presented to show the advantages of this design to a conventional pyrotechnic-based valve.

  2. Experimental validation of the fluid-structure interaction simulation of a bioprosthetic aortic heart valve.

    PubMed

    Kemp, I; Dellimore, K; Rodriguez, R; Scheffer, C; Blaine, D; Weich, H; Doubell, A

    2013-09-01

    Experiments performed on a 19 mm diameter bioprosthetic valve were used to successfully validate the fluid-structure interaction (FSI) simulation of an aortic valve at 72 bpm. The FSI simulation was initialized via a novel approach utilizing a Doppler sonogram of the experimentally tested valve. Using this approach very close quantitative agreement (≤12.5%) between the numerical predictions and experimental values for several key valve performance parameters, including the peak systolic transvalvular pressure gradient, rapid valve opening time and rapid valve closing time, was obtained. The predicted valve leaflet kinematics during opening and closing were also in good agreement with the experimental measurements. PMID:23907849

  3. A fibrous band associated with the non-coronary aortic valve cusp in a dog.

    PubMed

    Ajithdoss, Dharani K; Arenas-Gamboa, Angela M; Edwards, John F

    2011-06-01

    A fibrous band connecting the middle of the free edge (nodulus Arantii) of the non-coronary aortic valve cusp to the ascending aorta just above the level of the non-coronary sinus of Valsalva was observed in an asymptomatic, 11-year-old, male Border Collie. The fibrous band was unrelated to the cause of the death in this dog. Such fibrous bands are usually reported in humans with congenital bicuspid aortic valves. To our knowledge, this is the first report of a fibrous band in the aortic valve in a domestic animal. PMID:21641896

  4. [Surgical aortic valve replacement for acute Streptococcus viridans endocarditis with simultaneous moderate hemophilia A].

    PubMed

    Krawietz, W; Loracher, C; Struck, E; Schlimok, G; Falk, H

    1988-07-01

    This is a report of a 25-year-old patient with known aortic valve stenosis since early youth and hemophilia A, showing recurrent joint bleeding. Acute Streptococcus endocarditis induced aortic valve insufficiency resulting in cardiac failure. Aortic valve replacement was performed after substitution of factor VIII, during which intra- and postoperative bleeding was prolonged by pericardial adhesions. Heparin was administered during cardiopulmonary-bypass as usual, but usual postoperative cumarin therapy was not initiated due to prolonged PTT time. One year postoperatively, the patient was in an excellent condition and fully rehabilitated. PMID:3145652

  5. Transcatheter aortic valve implantation in a young heart transplant recipient crossing the traditional boundaries

    PubMed Central

    Terkelsen, Christian Juhl; Terp, Kim Allan; Mathiassen, Ole Norling; Nørgaard, Bjarne Linde; Andersen, Henning Rud; Poulsen, Steen Hvitfeldt

    2016-01-01

    Transcatheter aortic valve implantation (TAVI) is an established therapeutic alternative to surgical aortic valve replacement (SAVR) in high-risk or inoperable patients with symptomatic aortic valve stenosis. Hitherto, TAVI is not recommended in young and low-intermediate risk patients. However, TAVI may also serve as an alternative to SAVR in selected young patients, e.g., patients who have previously undergone multiple cardiac surgery procedures. We report a case of trans-femoral TAVI in a 25-year-old heart transplant (HTx) recipient with prior surgery for congenital heart disease. PMID:27621906

  6. A simple technique to rule out occlusion of right coronary artery after aortic valve surgery.

    PubMed

    Fernández, Angel L; El-Diasty, Mohammad M; Martínez, Amparo; Alvarez, Julian; García-Bengochea, José B

    2011-12-01

    Mechanical occlusion of the right coronary artery during aortic valve surgery is an infrequent but serious complication. Early recognition and expeditious management are important to reduce mortality. We developed a safe, quick, and easy technique to assess right coronary artery flow after aortic valve surgery. Direct intraoperative right coronary artery flow was measured by placing a transit-time flowmeter probe around the right coronary artery. We were able to promptly detect severe right coronary artery insufficiency in patients with acute unexpected right ventricular failure after aortic valve replacement. PMID:22115253

  7. Perceval S Valve Solution for Degenerated Freestyle Root in the Presence of Chronic Aortic Dissection.

    PubMed

    Lio, Antonio; Miceli, Antonio; Ferrarini, Matteo; Glauber, Mattia

    2016-06-01

    Aortic root replacement with porcine xenograft is a valuable treatment option in acute aortic dissection, but conduits are often prone to degeneration. Reoperation is still associated with high operative mortality, and it usually requires root removal and repetition of the Bentall procedure, or a less radical option limited to valve replacement. We describe two cases of Freestyle root degeneration in patients with chronic aortic dissection, in whom we performed a valve-in-valve procedure with the Perceval S prosthesis (Sorin Group, Saluggia, Italy). PMID:27211946

  8. An experimental study of apico-aortic valved conduit (AAVC) for surgical treatment of aortic stenosis in dogs.

    PubMed

    Hirao, Hidehiro; Inoue, Tomoki; Hoshi, Katsuichiro; Kobayashi, Masayuki; Shimamura, Shunsuke; Shimizu, Miki; Tanaka, Ryou; Takashima, Kazuaki; Mori, Yuichi; Noishiki, Yasuharu; Yamane, Yoshihisa

    2005-04-01

    A new valved conduit was developed using a canine aortic valve. The bioprosthetic valve was fixed with glutaraldehyde and epoxy compound (Denacol-EX313/810). A vascular graft composed of ultra-fine polyester fiber (10 mm in diameter, 200 mm in length) was used. Four dogs underwent apico-aortic valved conduit (AAVC) implantation and aortic banding (bypass group, BG), while another 4 dogs underwent aortic banding without AAVC implantation (control group, CG). Cardiac catheterization and angiocardiography were performed for assessment of hemodynamics 2 weeks and 6 months after surgery. Left ventricular systolic pressure, left ventricular end-diastolic pressure and the left ventricular-aortic pressure gradient differed significantly (P<0.01) between the BG and CG dogs. Left ventricular angiocardiography showed patency of the valved conduit in all the BG dogs. Echocardiography was performed before and 2, 4 and 6 months after surgery, and showed that while pressure overload caused concentric myocardial hypertrophy in the CG dogs, the left ventricle dilated eccentrically in the BG dogs. Furthermore, relief of left ventricular pressure overload by AAVC was maintained. PMID:15876784

  9. A Case of Severe Unicuspid Aortic Valve Stenosis: Valve Repair With Tricuspidization in an Adult.

    PubMed

    Tokue, Masahide; Hara, Hidehiko; Sahara, Naohiko; Yamazaki, Kenji; Yamashita, Hiromasa; Takahashi, Kei; Ozaki, Shigeyuki; Sugi, Kaoru; Nakamura, Masato

    2015-10-01

    A 33-year-old male was referred to our institute with acute heart failure. The patient was found to have a unicuspid aortic valve (UAV) and severe aortic stenosis. He had been followed at a local university hospital during childhood. However, he stopped visiting the outpatient clinic after becoming an adult. His condition subsequently worsened, and he ultimately presented to our hospital with cardiogenic shock. In Japan, some adult congenital heart disease (ACHD) patients continue to be followed by pediatric cardiologists, though the patterns of practice are variable. This report describes the case of a patient who became lost to follow-up in early adulthood. We thus focus on this ACHD case as an example of the effects of inadequate communication among doctors and the need to establish better ACHD management protocols for treating this patient population. PMID:26467883

  10. Embolic Protection Devices in Transcatheter Aortic Valve Replacement.

    PubMed

    Steinvil, Arie; Benson, Richard T; Waksman, Ron

    2016-03-01

    The initially reported periprocedural neurological events rates associated with transcatheter aortic valve replacement raised concerns that ultimately led to the development and to the clinical research of novel embolic protection devices. Although the reduction of clinical stroke is a desired goal, the current research design of embolic protection devices focuses on surrogate markers of the clinical disease, primarily on silent central nervous system lesions observed in postprocedural diffuse-weighted magnetic resonance imaging and cognitive function testing. As the mere presence of particulate debris in brain matter may not correlate with the extent of brain injury, cognitive function, or quality of life, the clinical significance of embolic protection devices has yet to be determined, and interpretation of study results with regard to real-life clinical use should be viewed accordingly. The purpose of this article is to provide an overview of the updated ongoing clinical research on embolic protection devices and present its major caveats. PMID:26951618