Science.gov

Sample records for liquid organic scintillator

  1. Positronium signature in organic liquid scintillators for neutrino experiments

    SciTech Connect

    Franco, D.; Consolati, G.; Trezzi, D.

    2011-01-15

    Electron antineutrinos are commonly detected in liquid scintillator experiments via inverse {beta} decay by looking at the coincidence between the reaction products: neutrons and positrons. Prior to positron annihilation, an electron-positron pair may form an orthopositronium (o-Ps) state, with a mean lifetime of a few nanoseconds. Even if the o-Ps decay is speeded up by spin-flip or pick-off effects, it may introduce distortions in the photon emission time distribution, crucial for position reconstruction and pulse shape discrimination algorithms in antineutrino experiments. Reversing the problem, the o-Ps-induced time distortion represents a new signature for tagging antineutrinos in liquid scintillator. In this article, we report the results of measurements of the o-Ps formation probability and lifetime for the most used solvents for organic liquid scintillators in neutrino physics (pseudocumene, linear alkyl benzene, phenylxylylethane, and dodecane). We characterize also a mixture of pseudocumene +1.5 g/l of 2,5-diphenyloxazole, a fluor acting as wavelength shifter. In the second part of the article, we demonstrate that the o-Ps-induced distortion of the scintillation photon emission time distributions represent an optimal signature for tagging positrons on an event by event basis, potentially enhancing the antineutrino detection.

  2. Organic liquid scintillation detector shape and volume impact on radiation portal monitors

    NASA Astrophysics Data System (ADS)

    Paff, Marc G.; Clarke, Shaun D.; Pozzi, Sara A.

    2016-07-01

    We have developed and tested a radiation portal monitor using organic liquid scintillation detectors. In order to optimize our system designs, neutron measurements were carried out with three organic liquid scintillation detectors of different shapes and sizes, along with a 3He radiation portal monitor (RPM) as a reference. The three liquids tested were a 7.62 cm diameter by 7.62 cm length cylindrical active volume organic liquid scintillation detector, a 12.7 cm diameter by 12.7 cm length cylindrical active volume organic liquid scintillation detector, and a 25 cm by 25 cm by 10 cm "paddle" shaped organic liquid scintillation detector. Background and Cf-252 neutron measurements were recorded to allow for a comparison of neutron intrinsic efficiencies as well as receiver operating characteristics (ROC) curves between detectors. The 12.7 cm diameter cylindrical active volume organic liquid scintillation detector exhibited the highest intrinsic neutron efficiency (54%) of all three liquid scintillators. An ROC curve analysis for a heavily moderated Cf-252 measurement showed that using the 12.7 cm diameter by 12.7 cm length cylindrical active volume Eljen EJ309 organic liquid scintillation detector would result in the fewest needed detector units in order to achieve a near 100% positive neutron alarm rate while maintaining a better than 1 in 10,000 false alarm rate on natural neutron background. A small number of organic liquid scintillation detectors could therefore be a valid alternative to 3He in some RPM applications.

  3. Fluorescence decay-time constants in organic liquid scintillators

    SciTech Connect

    Marrodan Undagoitia, T.; Feilitzsch, F. von; Oberauer, L.; Potzel, W.; Ulrich, A.; Winter, J.; Wurm, M.

    2009-04-15

    The fluorescence decay-time constants have been measured for several scintillator mixtures based on phenyl-o-xylylethane (PXE) and linear alkylbenzene (LAB) solvents. The resulting values are of relevance for the physics performance of the proposed large-volume liquid scintillator detector Low Energy Neutrino Astronomy (LENA). In particular, the impact of the measured values to the search for proton decay via p{yields}K{sup +}{nu} is evaluated in this work.

  4. Recent development in organic scintillators

    NASA Technical Reports Server (NTRS)

    Horrocks, D. L.; Wirth, H. O.

    1969-01-01

    Discussion on recent developments of organic scintillators includes studies of organic compounds that form glass-like masses which scintillate and are stable at room temperature, correlations between molecular structure of organic scintillators and self-quenching, recently developed fast scintillators, and applications of liquid-scintillation counters.

  5. Comparison of neutron spectra measured with three sizes of organic liquid scintillators using differentiation analysis

    NASA Technical Reports Server (NTRS)

    Shook, D. F.; Pierce, C. R.

    1972-01-01

    Proton recoil distributions were obtained by using organic liquid scintillators of different size. The measured distributions are converted to neutron spectra by differentiation analysis for comparison to the unfolded spectra of the largest scintillator. The approximations involved in the differentiation analysis are indicated to have small effects on the precision of neutron spectra measured with the smaller scintillators but introduce significant error for the largest scintillator. In the case of the smallest cylindrical scintillator, nominally 1.2 by 1.3 cm, the efficiency is shown to be insensitive to multiple scattering and to the angular distribution to the incident flux. These characteristics of the smaller scintillator make possible its use to measure scalar flux spectra within media high efficiency is not required.

  6. Lithium-loaded liquid scintillators

    DOEpatents

    Dai, Sheng; Kesanli, Banu; Neal, John S.

    2012-05-15

    The invention is directed to a liquid scintillating composition containing (i) one or more non-polar organic solvents; (ii) (lithium-6)-containing nanoparticles having a size of up to 10 nm and surface-capped by hydrophobic molecules; and (iii) one or more fluorophores. The invention is also directed to a liquid scintillator containing the above composition.

  7. Nanophosphor composite scintillator with a liquid matrix

    DOEpatents

    McKigney, Edward Allen; Burrell, Anthony Keiran; Bennett, Bryan L.; Cooke, David Wayne; Ott, Kevin Curtis; Bacrania, Minesh Kantilal; Del Sesto, Rico Emilio; Gilbertson, Robert David; Muenchausen, Ross Edward; McCleskey, Thomas Mark

    2010-03-16

    An improved nanophosphor scintillator liquid comprises nanophosphor particles in a liquid matrix. The nanophosphor particles are optionally surface modified with an organic ligand. The surface modified nanophosphor particle is essentially surface charge neutral, thereby preventing agglomeration of the nanophosphor particles during dispersion in a liquid scintillator matrix. The improved nanophosphor scintillator liquid may be used in any conventional liquid scintillator application, including in a radiation detector.

  8. Measurement of neutron dose with an organic liquid scintillator coupled with a spectrum weight function.

    PubMed

    Kim, E; Endo, A; Yamaguchi, Y; Yoshizawa, M; Nakamura, T

    2002-01-01

    A dose evaluation method for neutrons in the energy range of a few MeV to 100 MeV has been developed using a spectrum weight function (G-function), which is applied to an organic liquid scintillator of 12.7 cm in diameter and 12.7 cm in length. The G-function that converts the pulse height spectrum of the scintillator into the ambient dose equivalent, H*(10), was calculated by an unfolding method using successive approximation of the response function of the scintillator and the ambient dose equivalent per unit neutron fluence (H*(10) conversion coefficients) of ICRP 74. To verify the response function of the scintillator and the value of H*(10) evaluated by the G-function. pulse height spectra of the scintillator were measured in some different neutron fields, which have continuous energy, monoenergetic and quasi-monoenergetic spectra. Values of H*(10) estimated using the G-function and pulse height spectra of the scintillator were compared with those calculated using neutron energy spectra. These doses agreed with each other. From the results, it was concluded that H*(10) can be evaluated directly from the pulse height spectrum of the scintillator by applying the G-function proposed in this study. PMID:12212900

  9. Investigation of three-dimensional localisation of radioactive sources using a fast organic liquid scintillator detector

    NASA Astrophysics Data System (ADS)

    Gamage, K. A. A.; Joyce, M. J.; Taylor, G. C.

    2013-04-01

    In this paper we discuss the possibility of locating radioactive sources in space using a scanning-based method, relative to the three-dimensional location of the detector. The scanning system comprises an organic liquid scintillator detector, a tungsten collimator and an adjustable equatorial mount. The detector output is connected to a bespoke fast digitiser (Hybrid Instruments Ltd., UK) which streams digital samples to a personal computer. A radioactive source has been attached to a vertical wall and the data have been collected in two stages. In the first case, the scanning system was placed a couple of metres away from the wall and in the second case it moved few centimetres from the previous location, parallel to the wall. In each case data were collected from a grid of measurement points (set of azimuth angles for set of elevation angles) which covered the source on the wall. The discrimination of fast neutrons and gamma rays, detected by the organic liquid scintillator detector, is carried out on the basis of pulse gradient analysis. Images are then produced in terms of the angular distribution of events for total counts, gamma rays and neutrons for both cases. The three-dimensional location of the neutron source can be obtained by considering the relative separation of the centres of the corresponding images of angular distribution of events. The measurements have been made at the National Physical Laboratory, Teddington, Middlesex, UK.

  10. Pulse shape discrimination capability of metal-loaded organic liquid scintillators for a short-baseline reactor neutrino experiment

    NASA Astrophysics Data System (ADS)

    Kim, B. R.; Han, B. Y.; Jeon, E. J.; Joo, K. K.; Kang, Jeongsoo; Khan, N.; Kim, H. J.; Kim, Hyunsoo; Kim, J. Y.; Siyeon, Kim; Kim, S. C.; Kim, Yeongduk; Ko, Y. J.; Lee, Jaison; Lee, Jeong-Yeon; Lee, J. Y.; Ma, K. J.; Park, Hyeonseo; Park, H. K.; Park, K. S.; Seo, K. M.; Seon, Gwang-Min; Yeo, I. S.; Yeo, K. M.

    2015-05-01

    A new short-baseline (SBL) reactor neutrino experiment is proposed to investigate a reactor anti-neutrino anomaly. A liquid scintillator (LS) is used to detect anti-neutrinos emitted from a Hanaro reactor, and the pulse shape discrimination (PSD) ability of the metal-loaded organic LSs is evaluated on small-scale laboratory samples. PSD can be affected by selecting different base solvents, and several of the LSs used two different organic base solvents, such as linear alkyl benzene and di-isopropylnaphthalene. For the metallic content, gadolinium (Gd) or lithium (6Li) was loaded into a home-made organic LS and into a commercially available liquid scintillation cocktail. A feasibility study was performed for the PSD using several different liquid scintillation cocktails. In this work, the preparation and the PSD characteristics of a promising candidate, which will be used in an above-ground environment, are summarized and presented.

  11. Development of a new neutron monitor using a boron-loaded organic liquid scintillation detector

    NASA Astrophysics Data System (ADS)

    Rasolonjatovo, A. H. D.; Shiomi, T.; Kim, E.; Nakamura, T.; Nunomiya, T.; Endo, A.; Yamaguchi, Y.; Yoshizawa, M.

    2002-10-01

    A new type of neutron dose monitor was developed by using a 12.7 cm diameter×12.7 cm long boron-loaded organic liquid scintillation detector BC523A. This detector aims to have a response in the wide energy range of thermal energy to 100 MeV by using the H and C reactions to the fast neutrons of organic liquid and the 10B(n, α) reaction to thermalized neutrons in the liquid. The response functions of this detector were determined by the Monte Carlo simulation in the energy region from thermal energy to 100 MeV. Using these response functions, the spectrum-weighted dose function, G-function, to get the neutron dose from the light output spectrum of the detector was also determined by the unfolding technique. The calculated G-function was applied to determine the neutron dose in real neutron fields having energies ranging from thermal energy to several tens of MeV, where the light output spectra were measured with the BC523A detector. The thus-obtained ambient doses and effective doses show rather good agreement with the fluence-to-dose conversion factor given by ICRP 74. This detector will be useful as a wide-energy range neutron monitor.

  12. Neutron detection in nuclear astrophysics experiments: study of organic liquid scintillators

    NASA Astrophysics Data System (ADS)

    Ciani, Giovanni Francesco

    2016-02-01

    In order to study the nuclear reaction 13 C(α,n)16 O, crucial for the nucleosynthesis of heavy nuclei (A>58), the LUNA collaboration at Laboratori Nazionali del Gran Sasso, is looking for the best neutron detector to use in the set up. One of the possibilities is to use detectors based on cell filled with Organic Liquid Scintillator BC501A. These detectors are sensible to fast neutron, but also to gamma rays. A Pulse Shape Discrimination process using the Zero Crossing method has been performed to select only signals from neutrons. Comparing the neutron spectra after the Pulse Shape Discrimination and the spectrum from a GEANT4 simulations, the efficiency of the BC501A, in function of the neutron energy and varying the light threshold, has been evaluated.

  13. Free liquid scintillation counting bibliography

    SciTech Connect

    1996-12-31

    Packard Instrument Company announces the availability of its newly updated Bibliography of Packard Tri-Carb Liquid Scintillation Analyzers. This unique new booklet lists 628 references in which Packard Tri-Carb{reg_sign} liquid scintillation analyzers have been used in life science, environmental, nuclear power and archaeological measurements. All listings are cross-referenced by radionuclide, specific field of study and author.

  14. Laboratory studies on the removal of radon-born lead from KamLAND׳s organic liquid scintillator

    SciTech Connect

    Keefer, G.; Grant, C.; Piepke, A.; Ebihara, T.; Ikeda, H.; Kishimoto, Y.; Kibe, Y.; Koseki, Y.; Ogawa, M.; Shirai, J.; Takeuchi, S.; Mauger, C.; Zhang, C.; Schweitzer, G.; Berger, B. E.; Dazeley, S.; Decowski, M. P.; Detwiler, J. A.; Djurcic, Z.; Dwyer, D. A.; Efremenko, Y.; Enomoto, S.; Freedman, S. J.; Fujikawa, B. K.; Furuno, K.; Gando, A.; Gando, Y.; Gratta, G.; Hatakeyama, S.; Heeger, K. M.; Hsu, L.; Ichimura, K.; Inoue, K.; Iwamoto, T.; Kamyshkov, Y.; Karwowski, H. J.; Koga, M.; Kozlov, A.; Lane, C. E.; Learned, J. G.; Maricic, J.; Markoff, D. M.; Matsuno, S.; McKee, D.; McKeown, R. D.; Miletic, T.; Mitsui, T.; Motoki, M.; Nakajima, Kyo; Nakajima, Kyohei; Nakamura, K.; O׳Donnell, T.; Ogawa, H.; Piquemal, F.; Ricol, J. -S.; Shimizu, I.; Suekane, F.; Suzuki, A.; Svoboda, R.; Tajima, O.; Takemoto, Y.; Tamae, K.; Tolich, K.; Tornow, W.; Watanabe, Hideki; Watanabe, Hiroko; Winslow, L. A.; Yoshida, S.

    2014-09-28

    We studied the removal of radioactivity from liquid scintillator in preparation of a low background phase of KamLAND. We describe the methods and techniques developed to measure and efficiently extract radon decay products from liquid scintillator. Lastly, we report the radio-isotope reduction factors obtained when applying various extraction methods. During this study, distillation was identified as the most efficient method for removing radon daughters from liquid scintillator.

  15. Liquid scintillating fiber calorimetry prototype

    SciTech Connect

    Gui, M.; Brookes, D.; David, A.

    1995-08-01

    A full size liquid scintillating fiber spaghetti-hadronic calorimeter has been constructed and tested using cosmic rays at Texas A and M University. The purpose of this research is to find practical solutions for detectors to be used in extremely high radiation environments. The details of design and construction of this module are presented. The advantages of using liquid scintillating materials were investigated. Relevant subjects are addressed. Cosmic ray test results are compared with that of GEANT Monte Carlo simulations. Over all, they agree well with each other. The conclusion is that calorimeters utilizing this technique can be used in high radiation environments such as SSC colliding area.

  16. Radiopure Metal-Loaded Liquid Scintillator

    SciTech Connect

    Rosero, Richard; Yeh, Minfang

    2015-03-18

    Metal-loaded liquid scintillator plays a key role in particle and nuclear physics experiments. The applications of metal ions in various neutrino experiments and the purification methods for different scintillator components are discussed in this paper.

  17. Radiopure metal-loaded liquid scintillator

    SciTech Connect

    Rosero, Richard; Yeh, Minfang

    2015-08-17

    Metal-loaded liquid scintillator plays a key role in particle and nuclear physics experiments. The applications of metal ions in various neutrino experiments and the purification methods for different scintillator components are discussed in this paper.

  18. Detecting scintillations in liquid helium

    NASA Astrophysics Data System (ADS)

    Huffman, P. R.; McKinsey, D. N.

    2013-09-01

    We review our work in developing a tetraphenyl butadiene (TPB)-based detection system for a measurement of the neutron lifetime using magnetically confined ultracold neutrons (UCN). As part of the development of the detection system for this experiment, we studied the scintillation properties of liquid helium itself, characterized the fluorescent efficiencies of different fluors, and built and tested three detector geometries. We provide an overview of the results from these studies as well as references for additional information.

  19. Digital processing of signals arising from organic liquid scintillators for applications in the mixed-field assessment of nuclear threats

    NASA Astrophysics Data System (ADS)

    Aspinall, M. D.; Joyce, M. J.; Mackin, R. O.; Jarrah, Z.; Peyton, A. J.

    2008-10-01

    The nuclear aspect of the CBRN* threat is often divided amongst radiological substances posing no criticality risk, often referred to as 'dirty bomb' scenarios, and fissile threats. The latter have the theoretical potential for criticality excursion, resulting in elevated neutron fluxes in addition to the γ-ray component that is common to dirty bombs. Even in isolation of the highly-unlikely criticality scenario, fissile substances often exhibit radiation fields comprising a significant neutron component which can require considerably different counterterrorism measures and clean-up methodologies. The contrast between these threats can indicate important differences in the relative sophistication of the perpetrators and their organizations. Consequently, the detection and discrimination of nuclear perils in terms of mixed-field content is an important assay in combating terrorist threats. In this paper we report on the design and implementation of a fast digitizer and embedded-processor for onthe- fly signal processing of events from organic liquid scintillators. A digital technique, known as Pulse Gradient Analysis (PGA), has been developed at Lancaster University for the digital discrimination of neutrons and γ rays. PGA has been deployed on bespoke hardware and demonstrates remarkable improvement over analogue methods for the assay of mixed fields and the real-time discrimination of neutrons and γ rays. In this regard the technology constitutes an attractive and affordable means for the discrimination of the radiation fields arising from fissile threats and those from dirty bombs. Data are presented demonstrating this capability with sealed radioactive sources.

  20. Plasmonic light yield enhancement of a liquid scintillator

    SciTech Connect

    Bignell, Lindsey J.; Jackson, Timothy W.; Mume, Eskender; Lee, George P.

    2013-05-27

    We demonstrate modifications to the light yield properties of an organic liquid scintillator due to the localization of the tertiary fluorophore component to the surface of Ag-core silica-shell nanoparticles. We attribute this enhancement to the near-field interaction of Ag nanoparticle plasmons with these fluor molecules. The scintillation light yield enhancement is shown to be equal to the fluorescence enhancement within measurement uncertainties. With a suitable choice of plasmon energy and scintillation fluor, this effect may be used to engineer scintillators with enhanced light yields for radiation detection applications.

  1. Plasmonic light yield enhancement of a liquid scintillator

    NASA Astrophysics Data System (ADS)

    Bignell, Lindsey J.; Mume, Eskender; Jackson, Timothy W.; Lee, George P.

    2013-05-01

    We demonstrate modifications to the light yield properties of an organic liquid scintillator due to the localization of the tertiary fluorophore component to the surface of Ag-core silica-shell nanoparticles. We attribute this enhancement to the near-field interaction of Ag nanoparticle plasmons with these fluor molecules. The scintillation light yield enhancement is shown to be equal to the fluorescence enhancement within measurement uncertainties. With a suitable choice of plasmon energy and scintillation fluor, this effect may be used to engineer scintillators with enhanced light yields for radiation detection applications.

  2. Metal-loaded organic scintillators for neutrino physics

    NASA Astrophysics Data System (ADS)

    Buck, Christian; Yeh, Minfang

    2016-09-01

    Organic liquid scintillators are used in many neutrino physics experiments of the past and present. In particular for low energy neutrinos when realtime and energy information are required, liquid scintillators have several advantages compared to other technologies. In many cases the organic liquid needs to be loaded with metal to enhance the neutrino signal over background events. Several metal loaded scintillators of the past suffered from chemical and optical instabilities, limiting the performance of these neutrino detectors. Different ways of metal loading are described in the article with a focus on recent techniques providing metal loaded scintillators that can be used under stable conditions for many years even in ton scale experiments. Applications of metal loaded scintillators in neutrino experiments are reviewed and the performance as well as the prospects of different scintillator types are compared.

  3. Rayleigh scattering of linear alkylbenzene in large liquid scintillator detectors

    SciTech Connect

    Zhou, Xiang Zhang, Zhenyu; Liu, Qian; Zheng, Yangheng; Wurm, Michael; Zhang, Qingmin; Ding, Yayun; Zhou, Li; Cao, Jun; Wang, Yifang

    2015-07-15

    Rayleigh scattering poses an intrinsic limit for the transparency of organic liquid scintillators. This work focuses on the Rayleigh scattering length of linear alkylbenzene (LAB), which will be used as the solvent of the liquid scintillator in the central detector of the Jiangmen Underground Neutrino Observatory. We investigate the anisotropy of the Rayleigh scattering in LAB, showing that the resulting Rayleigh scattering length will be significantly shorter than reported before. Given the same overall light attenuation, this will result in a more efficient transmission of photons through the scintillator, increasing the amount of light collected by the photosensors and thereby the energy resolution of the detector.

  4. Neutron detection with single crystal organic scintillators

    SciTech Connect

    Zaitseva, N; Newby, J; Hamel, S; Carman, L; Faust, M; Lordi, V; Cherepy, N; Stoeffl, W; Payne, S

    2009-07-15

    Detection of high-energy neutrons in the presence of gamma radiation background utilizes pulse-shape discrimination (PSD) phenomena in organics studied previously only with limited number of materials, mostly liquid scintillators and single crystal stilbene. The current paper presents the results obtained with broader varieties of luminescent organic single crystals. The studies involve experimental tools of crystal growth and material characterization in combination with the advanced computer modeling, with the final goal of better understanding the relevance between the nature of the organic materials and their PSD properties. Special consideration is given to the factors that may diminish or even completely obscure the PSD properties in scintillating crystals. Among such factors are molecular and crystallographic structures that determine exchange coupling and exciton mobility in organic materials and the impurity effect discussed on the examples of trans-stilbene, bibenzyl, 9,10-diphenylanthracene and diphenylacetylene.

  5. Neutron detection with single crystal organic scintillators

    NASA Astrophysics Data System (ADS)

    Zaitseva, Natalia P.; Newby, Jason; Hamel, Sebastien; Carman, Leslie; Faust, Michelle; Lordi, Vincenzo; Cherepy, Nerine J.; Stoeffl, Wolfgang; Payne, Stephen A.

    2009-08-01

    Detection of high-energy neutrons in the presence of gamma radiation background utilizes pulse-shape discrimination (PSD) phenomena in organics studied previously only with limited number of materials, mostly liquid scintillators and single crystal stilbene. The current paper presents the results obtained with broader varieties of luminescent organic single crystals. The studies involve experimental tools of crystal growth and material characterization in combination with the advanced computer modeling, with the final goal of better understanding the relevance between the nature of the organic materials and their PSD properties. Special consideration is given to the factors that may diminish or even completely obscure the PSD properties in scintillating crystals. Among such factors are molecular and crystallographic structures that determine exchange coupling and exciton mobility in organic materials and the impurity effect discussed on the examples of trans-stilbene, bibenzyl, 9,10- diphenylanthracene and diphenylacetylene.

  6. Mixed crystal organic scintillators

    DOEpatents

    Zaitseva, Natalia P; Carman, M Leslie; Glenn, Andrew M; Hamel, Sebastien; Hatarik, Robert; Payne, Stephen A; Stoeffl, Wolfgang

    2014-09-16

    A mixed organic crystal according to one embodiment includes a single mixed crystal having two compounds with different bandgap energies, the organic crystal having a physical property of exhibiting a signal response signature for neutrons from a radioactive source, wherein the signal response signature does not include a significantly-delayed luminescence characteristic of neutrons interacting with the organic crystal relative to a luminescence characteristic of gamma rays interacting with the organic crystal. According to one embodiment, an organic crystal includes bibenzyl and stilbene or a stilbene derivative, the organic crystal having a physical property of exhibiting a signal response signature for neutrons from a radioactive source.

  7. Measurement of radiation damage of water-based liquid scintillator and liquid scintillator

    DOE PAGESBeta

    Bignell, L. J.; Diwan, M. V.; Hans, S.; Jaffe, D. E.; Rosero, R.; Vigdor, S.; Viren, B.; Worcester, E.; Yeh, M.; Zhang, C.

    2015-10-19

    Liquid scintillating phantoms have been proposed as a means to perform real-time 3D dosimetry for proton therapy treatment plan verification. We have studied what effect radiation damage to the scintillator will have upon this application. We have performed measurements of the degradation of the light yield and optical attenuation length of liquid scintillator and water-based liquid scintillator after irradiation by 201 MeV proton beams that deposited doses of approximately 52 Gy, 300 Gy, and 800 Gy in the scintillator. Liquid scintillator and water-based liquid scintillator (composed of 5% scintillating phase) exhibit light yield reductions of 1.74 ± 0.55 % andmore » 1.31 ± 0.59 % after ≈ 800 Gy of proton dose, respectively. Some increased optical attenuation was observed in the irradiated samples, the measured reduction to the light yield is also due to damage to the scintillation light production. Based on our results and conservative estimates of the expected dose in a clinical context, a scintillating phantom used for proton therapy treatment plan verification would exhibit a systematic light yield reduction of approximately 0.1% after a year of operation.« less

  8. Measurement of radiation damage of water-based liquid scintillator and liquid scintillator

    SciTech Connect

    Bignell, L. J.; Diwan, M. V.; Hans, S.; Jaffe, D. E.; Rosero, R.; Vigdor, S.; Viren, B.; Worcester, E.; Yeh, M.; Zhang, C.

    2015-10-19

    Liquid scintillating phantoms have been proposed as a means to perform real-time 3D dosimetry for proton therapy treatment plan verification. We have studied what effect radiation damage to the scintillator will have upon this application. We have performed measurements of the degradation of the light yield and optical attenuation length of liquid scintillator and water-based liquid scintillator after irradiation by 201 MeV proton beams that deposited doses of approximately 52 Gy, 300 Gy, and 800 Gy in the scintillator. Liquid scintillator and water-based liquid scintillator (composed of 5% scintillating phase) exhibit light yield reductions of 1.74 ± 0.55 % and 1.31 ± 0.59 % after ≈ 800 Gy of proton dose, respectively. Some increased optical attenuation was observed in the irradiated samples, the measured reduction to the light yield is also due to damage to the scintillation light production. Based on our results and conservative estimates of the expected dose in a clinical context, a scintillating phantom used for proton therapy treatment plan verification would exhibit a systematic light yield reduction of approximately 0.1% after a year of operation.

  9. Liquid scintillators for optical fiber applications

    DOEpatents

    Franks, Larry A.; Lutz, Stephen S.

    1982-01-01

    A multicomponent liquid scintillator solution for use as a radiation-to-light converter in conjunction with a fiber optic transmission system. The scintillator includes a quantity of 1, 2, 4, 5, 3H, 6H, 1 OH, tetrahydro-8-trifluoromethyl (1) benzopyrano (9, 9a, 1-gh) quinolizin-10-one (Coumarin) as a solute in a fluor solvent such as benzyl alcohol or pseudo-cumene. The use of BIBUQ as an additional or primary solute is also disclosed.

  10. Ternary liquid scintillator for optical fiber applications

    DOEpatents

    Franks, Larry A.; Lutz, Stephen S.

    1982-01-01

    A multicomponent liquid scintillator solution for use as a radiation-to-light converter in conjunction with a fiber optic transmission system. The scintillator includes a quantity of 5-amino-9-diethylaminobenz (a) phenoxazonium nitrate (Nile Blue Nitrate) as a solute in a fluor solvent such as benzyl alcohol. The use of PPD as an additional solute is also disclosed. The system is controllable by addition of a suitable quenching agent, such as phenol.

  11. Pulse shaping analysis with LAB-based liquid scintillators

    NASA Astrophysics Data System (ADS)

    Lee, J. S.; Kim, Y. H.; Lee, K. B.; Lee, M. K.; Ma, K. J.; Jeon, E. J.; Kim, J. Y.; Kim, N. Y.; Kim, Y. D.; Lee, J. Y.

    2012-02-01

    We report on a pulse shaping analysis for alpha-beta discrimination using a linear alkylbenzene (LAB)-based liquid scintillator developed for reactor neutrino experiments. The scintillation properties are measured with an internal alpha source diluted in the same scintillator and an external gamma source. The comparison of the fast and the slow parts in the signal waveforms provide clear separations of alpha and gamma events in the liquid scintillator. The discrimination power is compared between the LAB-based liquid scintillator and other commercially available liquid scintillators. The potential use of this scintillator when loaded with 6Li is discussed with regard to neutron measurements.

  12. Near-infrared scintillation of liquid argon

    NASA Astrophysics Data System (ADS)

    Alexander, T.; Escobar, C. O.; Lippincott, W. H.; Rubinov, P.

    2016-03-01

    Since the 1970s it has been known that noble gases scintillate in the near infrared (NIR) region of the spectrum (0.7 μm < λ < 1.5 μm). More controversial has been the question of the NIR light yield for condensed noble gases. We first present the motivation for using the NIR scintillation in liquid argon detectors, then briefly review early as well as more recent efforts and finally show encouraging preliminary results of a test performed at Fermilab.

  13. Measurements of high energy neutrons penetrated through iron shields using the Self-TOF detector and an NE213 organic liquid scintillator

    NASA Astrophysics Data System (ADS)

    Sasaki, M.; Nakao, N.; Nunomiya, T.; Nakamura, T.; Fukumura, A.; Takada, M.

    2002-11-01

    Neutron energy spectra penetrated through iron shields were measured using the Self-TOF detector and an NE213 organic liquid scintillator which have been newly developed by our group at the Heavy-Ion Medical Accelerator in Chiba (HIMAC) of National Institute of Radiological Sciences (NIRS), Japan. Neutrons were generated by bombarding 400 MeV/nucleon C ion on a thick (stopping-length) copper target. The neutron spectra in the energy range from 20 to 800 MeV were obtained through the FORIST unfolding code with their response functions and compared with the MCNPX calculations combined with the LA150 cross section library. The neutron fluence measured by the NE213 detector was simulated by the track length estimator in the MCNPX, and evaluated the contribution of the room-scattered neutrons. The calculations are in fairly good agreement with the measurements. Neutron fluence attenuation lengths were obtained from the experimental results and the calculation.

  14. Organic liquid scintillation detectors for on-the-fly neutron/gamma alarming and radionuclide identification in a pedestrian radiation portal monitor

    NASA Astrophysics Data System (ADS)

    Paff, Marc Gerrit; Ruch, Marc L.; Poitrasson-Riviere, Alexis; Sagadevan, Athena; Clarke, Shaun D.; Pozzi, Sara

    2015-07-01

    We present new experimental results from a radiation portal monitor based on the use of organic liquid scintillators. The system was tested as part of a 3He-free radiation portal monitor testing campaign at the European Commission's Joint Research Centre in Ispra, Italy, in February 2014. The radiation portal monitor was subjected to a wide range of test conditions described in ANSI N42.35, including a variety of gamma-ray sources and a 20,000 n/s 252Cf source. A false alarm test tested whether radiation portal monitors ever alarmed in the presence of only natural background. The University of Michigan Detection for Nuclear Nonproliferation Group's system triggered zero false alarms in 2739 trials. It consistently alarmed on a variety of gamma-ray sources travelling at 1.2 m/s at a 70 cm source to detector distance. The neutron source was detected at speeds up to 3 m/s and in configurations with up to 8 cm of high density polyethylene shielding. The success of on-the-fly radionuclide identification varied with the gamma-ray source measured as well as with which of two radionuclide identification methods was used. Both methods used a least squares comparison between the measured pulse height distributions to library spectra to pick the best match. The methods varied in how the pulse height distributions were modified prior to the least squares comparison. Correct identification rates were as high as 100% for highly enriched uranium, but as low as 50% for 241Am. Both radionuclide identification algorithms produced mixed results, but the concept of using liquid scintillation detectors for gamma-ray and neutron alarming in radiation portal monitor was validated.

  15. Light yield and energy transfer in a new Gd-loaded liquid scintillator

    NASA Astrophysics Data System (ADS)

    Aberle, C.; Buck, C.; Hartmann, F. X.; Schönert, S.

    2011-11-01

    We investigate a new gadolinium-loaded organic liquid scintillator which is designed to detect electron antineutrinos. A model has been developed to account for the various energy transfer paths possible in a liquid scintillator with multiple solvents, one fluor and a quenching component. Experimental light yield measurements were carried out to determine the relative rates for the energy transfers included in the model. Model predictions were used to tune the luminescent properties of the Gd-loaded target scintillator and the unloaded Gamma Catcher scintillator for the reactor neutrino experiment Double Chooz.

  16. Large-scale liquid scintillation detectors for solar neutrinos

    NASA Astrophysics Data System (ADS)

    Benziger, Jay B.; Calaprice, Frank P.

    2016-04-01

    Large-scale liquid scintillation detectors are capable of providing spectral yields of the low energy solar neutrinos. These detectors require > 100 tons of liquid scintillator with high optical and radiopurity. In this paper requirements for low-energy neutrino detection by liquid scintillation are specified and the procedures to achieve low backgrounds in large-scale liquid scintillation detectors for solar neutrinos are reviewed. The designs, operations and achievements of Borexino, KamLAND and SNO+ in measuring the low-energy solar neutrino fluxes are reviewed.

  17. Liquid Scintillation Detectors for High Energy Neutrinos

    SciTech Connect

    Smith, Stefanie N.; Learned, John G.

    2010-03-30

    Large open volume (not segmented) liquid scintillation detectors have been generally dedicated to low energy neutrino measurements, in the MeV energy region. We describe the potential employment of large detectors (>1 kiloton) for studies of higher energy neutrino interactions, such as cosmic rays and long-baseline experiments. When considering the physics potential of new large instruments the possibility of doing useful measurements with higher energy neutrino interactions has been overlooked. Here we take into account Fermat's principle, which states that the first light to reach each PMT will follow the shortest path between that PMT and the point of origin. We describe the geometry of this process, and the resulting wavefront, which we are calling the 'Fermat surface', and discuss methods of using this surface to extract directional track information and particle identification. This capability may be demonstrated in the new long-baseline neutrino beam from Jaeri accelerator to the KamLAND detector in Japan. Other exciting applications include the use of Hanohano as a movable long-baseline detector in this same beam, and LENA in Europe for future long-baseline neutrino beams from CERN. Also, this methodology opens up the question as to whether a large liquid scintillator detector should be given consideration for use in a future long-baseline experiment from Fermilab to the DUSEL underground laboratory at Homestake.

  18. Pulse shape discrimination with lithium-containing organic scintillators

    NASA Astrophysics Data System (ADS)

    Zaitseva, Natalia; Glenn, Andrew; Paul Martinez, H.; Carman, Leslie; Pawełczak, Iwona; Faust, Michelle; Payne, Stephen

    2013-11-01

    6Li-containing organic scintillators have been prepared and characterized as a new type of transparent, single-phase materials with pulse shape discrimination (PSD) properties for simultaneous detection of thermal and fast neutrons discriminated from gamma radiation. Tests conducted with recently developed PSD-capable plastic scintillators showed that incorporation of 6Li into the aromatic matrix with fast-neutron/gamma discrimination properties offers the additional sensitivity to thermal neutrons, substantially increasing efficiency and the energy range of neutron detection. Comparative analyses of 6Li-loaded plastic, liquid and single crystal organic scintillators provide evidence that, in addition to neutron/gamma discrimination, these novel materials have the ability for discrimination between the signatures of fast and thermal neutrons.

  19. Optical scattering lengths in large liquid-scintillator neutrino detectors

    SciTech Connect

    Wurm, M.; Feilitzsch, F. von; Goeger-Neff, M.; Hofmann, M.; Lewke, T.; Meindl, Q.; Moellenberg, R.; Oberauer, L.; Potzel, W.; Tippmann, M.; Todor, S.; Winter, J.; Lachenmaier, T.; Traunsteiner, C.; Undagoitia, T. Marrodan

    2010-05-15

    For liquid-scintillator neutrino detectors of kiloton scale, the transparency of the organic solvent is of central importance. The present paper reports on laboratory measurements of the optical scattering lengths of the organic solvents phenylxylylethane, linear alkylbenzene (LAB), and dodecane, which are under discussion for next-generation experiments such as SNO+ (Sudbury Neutrino Observatory), HanoHano, or LENA (Low Energy Neutrino Astronomy). Results comprise the wavelength range of 415-440 nm. The contributions from Rayleigh and Mie scattering as well as from absorption/re-emission processes are discussed. Based on the present results, LAB seems to be the preferred solvent for a large-volume detector.

  20. Purification of KamLAND-Zen liquid scintillator

    NASA Astrophysics Data System (ADS)

    Ikeda, Haruo

    2013-08-01

    KamLAND-Zen is neutrino-less double-beta decay search experiment using enriched 300 kg of 136Xe dissolved in pure liquid scintillator. This report is purification work of liquid scintillator for KamLAND-Zen experiment before installation in the inner-balloon and background rejection processes after installation.

  1. Purification of KamLAND-Zen liquid scintillator

    SciTech Connect

    Ikeda, Haruo

    2013-08-08

    KamLAND-Zen is neutrino-less double-beta decay search experiment using enriched 300 kg of {sup 136}Xe dissolved in pure liquid scintillator. This report is purification work of liquid scintillator for KamLAND-Zen experiment before installation in the inner-balloon and background rejection processes after installation.

  2. Liquid scintillator production for the NOvA experiment

    NASA Astrophysics Data System (ADS)

    Mufson, S.; Baugh, B.; Bower, C.; Coan, T. E.; Cooper, J.; Corwin, L.; Karty, J. A.; Mason, P.; Messier, M. D.; Pla-Dalmau, A.; Proudfoot, M.

    2015-11-01

    The NOvA collaboration blended and delivered 8.8 kt (2.72M gal) of liquid scintillator as the active detector medium to its near and far detectors. The composition of this scintillator was specifically developed to satisfy NOvA's performance requirements. A rigorous set of quality control procedures was put in place to verify that the incoming components and the blended scintillator met these requirements. The scintillator was blended commercially in Hammond, IN. The scintillator was shipped to the NOvA detectors using dedicated stainless steel tanker trailers cleaned to food grade.

  3. Liquid Scintillator Production for the NOvA Experiment

    DOE PAGESBeta

    Mufson, S.; Baugh, B.; Bower, C.; Coan, T.; Cooper, J.; Corwin, L.; Karty, J.; Mason, P.; Messier, M. D.; Pla-Dalmau, A.; et al

    2015-04-15

    The NOvA collaboration blended and delivered 8.8 kt (2.72M gal) of liquid scintillator as the active detector medium to its near and far detectors. The composition of this scintillator was specifically developed to satisfy NOvA's performance requirements. A rigorous set of quality control procedures was put in place to verify that the incoming components and the blended scintillator met these requirements. The scintillator was blended commercially in Hammond, IN. The scintillator was shipped to the NOvA detectors using dedicated stainless steel tanker trailers cleaned to food grade.

  4. Measurement of ortho-positronium properties in liquid scintillators

    NASA Astrophysics Data System (ADS)

    Perasso, S.; Consolati, G.; Franco, D.; Hans, S.; Jollet, C.; Meregaglia, A.; Tonazzo, A.; Yeh, M.

    2013-08-01

    Pulse shape discrimination in liquid scintillator detectors is a well-established technique for the discrimination of heavy particles from light particles. Nonetheless, it is not efficient in the separation of electrons and positrons, as they give rise to indistinguishable scintillator responses. This inefficiency can be overtaken through the exploitation of the formation of ortho-Positronium (o-Ps), which alters the time profile of light pulses induced by positrons. We characterized the o-Ps properties in the most commonly used liquid scintillators, i.e. PC, PXE, LAB, OIL and PC + PPO. In addition, we studied the effects of scintillator doping on the o-Ps properties for dopants currently used in neutrino experiments, Gd and Nd. Further measurements for Li-loaded and Tl-loaded liquid scintillators are foreseen. We found that the o-Ps properties are suitable for enhancing the electron-positron discrimination.

  5. Measurement of ortho-positronium properties in liquid scintillators

    SciTech Connect

    Perasso, S.; Franco, D.; Tonazzo, A.; Consolati, G.; Hans, S.; Yeh, M.; Jollet, C.; Meregaglia, A.

    2013-08-08

    Pulse shape discrimination in liquid scintillator detectors is a well-established technique for the discrimination of heavy particles from light particles. Nonetheless, it is not efficient in the separation of electrons and positrons, as they give rise to indistinguishable scintillator responses. This inefficiency can be overtaken through the exploitation of the formation of ortho-Positronium (o-Ps), which alters the time profile of light pulses induced by positrons. We characterized the o-Ps properties in the most commonly used liquid scintillators, i.e. PC, PXE, LAB, OIL and PC + PPO. In addition, we studied the effects of scintillator doping on the o-Ps properties for dopants currently used in neutrino experiments, Gd and Nd. Further measurements for Li-loaded and Tl-loaded liquid scintillators are foreseen. We found that the o-Ps properties are suitable for enhancing the electron-positron discrimination.

  6. Measurement of the liquid scintillator nonlinear energy response to electron

    NASA Astrophysics Data System (ADS)

    Zhang, Fei-Hong; Yu, Bo-Xiang; Hu, Wei; Yang, Ma-Sheng; Cao, Guo-Fu; Cao, Jun; Zhou, Li

    2015-01-01

    Nonlinearity of the liquid scintillator energy response is a key to measuring the neutrino energy spectrum in reactor neutrino experiments such as Daya Bay and JUNO. We measured the nonlinearity of the linear alkyl benzene based liquid scintillator in the laboratory, which is used in Daya Bay and will be used in JUNO, via the Compton scattering process. By tagging the scattered gamma from the liquid scintillator sample simultaneously at seven angles, the instability of the system was largely cancelled. The accurately measured nonlinearity will improve the precision of the θ13, Δm2, and reactor neutrino spectrum measurements at Daya Bay.

  7. Liquid Scintillator based experiments in Neutrinoless Double Beta Decay

    NASA Astrophysics Data System (ADS)

    Nakamura, K.; KamLAND-Zen Collaboration

    2012-08-01

    Recent experiments have confirmed neutrino oscillations. The mass structure of neutrinos is one of the next interesting subjects in neutrino physics. Neutrinoless double beta decay has the potential to investigate the mass structure of neutrinos. Many neutrinoless double beta decay experiments are being proposed and some were introduced at this conference. Here we present neutrinoless double beta decay experiments based on liquid scintillator techniques. SNO+ plans to use 150Nd as the neutrinoless double beta decay isotope dissolved in liquid scintillator, similarly KamLAND-Zen will use 136Xe loaded liquid scintillator. The physics goals, schedule and current status of both experiments were discussed.

  8. Alpha counting and spectrometry using liquid scintillation methods

    SciTech Connect

    McDowell, W J

    1986-01-01

    The material in this report is intended to be a practical introduction and guide to the use of liquid scintillation for alpha counting and spectrometry. Other works devoted to the development of the theory of liquid scintillation exist and a minimum of such material is repeated here. Much remains to be learned and many improvements remain to be made in the use of liquid scintillation for alpha counting and spectrometry. It is hoped that this modest work will encourage others to continue development in the field.

  9. Liquid Scintillator Light Yield Measurements for the SNO+ Experiment

    NASA Astrophysics Data System (ADS)

    Grullon, Sean

    2013-04-01

    The SNO+ experiment is the follow-up to the Sudbury Neutrino Observatory (SNO). The heavy water that was in SNO will be replaced with a liquid scintillator of linear alkylbenzene. SNO+ will have a broad physics program which will include measuring the pep and CNO solar neutrino flux, detecting geo-neutrinos, studying reactor neutrino oscillations, serving as a supernova neutrino detector, and carrying out a search for neutrinoless double beta decay by loading an isotope such as neodymium into the liquid scintillator. Since energy resolution is of profound importance for the experiment, it is extremely important to accurately measure the light yield of the liquid scintillator for different loading percentages of Neodymium. A series of measurements made comparing the relative light yields of different liquid scintillator configurations to a Cherenkov spectrum will be described.

  10. Data analysis in solar neutrinos liquid-scintillator detectors

    NASA Astrophysics Data System (ADS)

    Testera, G.

    2016-04-01

    This paper focuses on the description of some of the methods developed to extract the solar neutrino signal from the background by the two running experiments (Borexino and Kamland) based on the use of a large volume of liquid scintillator.

  11. A quick liquid scintillation counting technique for analysis of ⁹⁰Sr in environmental samples.

    PubMed

    Wang, Jeng-Jong

    2013-11-01

    In this study, to improve the problem of waiting for the growth of (90)Y for Cerenkov counting and save the time of (90)Sr analysis, an organic cocktail sample was counted by a liquid scintillation counting system immediately after the purification of (90)Sr without waiting for the growth of (90)Y. The chemical separation and the measurement procedures for (90)Sr radioactivity analysis can be completed in 24h. In order to verify the performance of the improved method, the activity of (90)Sr in six environmental reference samples was determined after radiochemical purification with a crown-ether resin column, and subsequent measurement by both the Cerenkov and the organic cocktail liquid scintillation counting methods. The results revealed that the organic cocktail liquid scintillation counting was quicker and had higher efficiency and lower minimum detectable activity (MDA) than the Cerenkov counting. PMID:23582495

  12. Response of liquid scintillator assemblies as a function of angular orientation

    NASA Astrophysics Data System (ADS)

    Naeem, S. F.; Scarpelli, M.; Miller, E.; Clarke, S. D.; Pozzi, S. A.

    2014-06-01

    Liquid scintillator detector assemblies contain an inert nitrogen expansion volume to allow for expansion of the liquid with changing temperature. Measurements and Geant4 Monte Carlo simulations are performed to study the dependence of pulse height distribution shapes as a function of detector angle for two liquid scintillators assemblies filled with 97% organic-liquid cocktail and a 3% expansion volume. A 12.7-cm diameter by 12.7-cm long and a 7.6-cm diameter by 9.1-cm long EJ-309 liquid scintillator assemblies are investigated using a 137Cs gamma-ray source. Aside from the differences in dimensions, the detector assemblies also differed in the design of the active detector volume: there is no light guide in the 12.7-cm-diameter detector assembly, whereas the 7.6-cm-diameter detector contains a BK7 light guide between the scintillation liquid and optical coupling to the photomultiplier tube. Results for the 12.7-cm-diameter detector show a decrease in the position of the Compton edge ranges from 4% to 40% at detector orientations where the expansion volume exists between scintillating medium and the photomultiplier tube. Results for the 7.6-cm-diameter detector show that the position of the Compton edge is relatively unaffected at all detector orientations due to the presence of light guide.

  13. Calorimetry using organic scintillators, 'a sideways perspective'.

    SciTech Connect

    Proudfoot, J.

    1999-09-10

    Over the last two decades, calorimetry baaed on organic scintillators has developed into an excellent technology for many experimental situations in high energy physics. The primary difficulty, that of extracting the light signals, has benefited from two milestone innovations. The first was the use of wavelength-shifting bars to allow light to be efficiently collected from large areas of scintillator and then readily piped to a readout device. The second of these was the extension of this approach to plastic wavelength-shifting optical fibers whose great flexibility and small diameter allowed a minimum of detector volume to be compromised by the read-out. These two innovations coupled with inventiveness have produced many varied and successful calorimeters. Equal response to both hadronic and electromagnetic showers can be realized in scintillator-based calorimeters. However, in general this is not the case and it is likely that in the search for greater performance, in the future, combined tracking and calorimeter systems will be required.

  14. Time profile of the scintillation from liquid and gaseous xenon

    NASA Astrophysics Data System (ADS)

    Murayama, Ikuko; Nakamura, Shogo

    2014-11-01

    The decay time profile of vacuum ultraviolet scintillation induced by electronic recoils has been studied for liquid and gaseous xenon. The scintillation light from xenon excited by a gamma source was measured by using two vacuum ultraviolet sensitive photomultipliers, one for detecting scintillation and the other for counting photons of weak monochromatic light. The analysis results based on the time-correlated single photon counting method show that the time profile in the 176 nm scintillation decay curve for liquid xenon is consistent with a single exponential component and the decay time constant is 31.5±1.3 ns. This constant does not change significantly for pressure ranges between 90 kPa and 130 kPa. There is no emission wavelength dependence of the decay constant. The result corresponds to an average on electronic recoil energies up to 1.3 MeV.

  15. Gasolines as primary solvents in liquid scintillation counting

    SciTech Connect

    Fernandez, A.; Ma Pinto, R.; Sillero, A.

    1986-11-01

    Gasolines from several commercial sources have been used as primary solvents in liquid scintillation counting of dry and aqueous samples of either /sup 3/H- or /sup 14/C-labeled compounds. Dry samples can be counted only by the addition of fluors to the gasolines, and compared to a standard liquid scintillator, efficiencies of around 75% were attained. For the counting of aqueous samples, gasolines must also be supplemented with secondary solvents (i.e., 10% naphthalene, 5% Triton X-100, or 10% methanol). Simply with Triton X-100, efficiencies similar to those obtained with a dioxane-based liquid scintillator were observed in the case of some gasolines. Drawbacks to gasoline are the higher toxicity and the variation of efficiency, probably depending on the presence of color markers. On the positive side is the low price of the gasolines, compared with either toluene or dioxane, and the facility of purchasing.

  16. Scintillation Efficiency of Liquid Xenon for Low Energy Nuclear Recoils

    NASA Astrophysics Data System (ADS)

    Wongjirad, Taritree; Ni, Kaixuan; Manzur, Angel; Kastens, Louis; McKinsey, Daniel

    2008-04-01

    In early 2006, the XENON and ZEPLIN collaborations announced highly stringent upper limits on the WIMP-nucleon cross-section. However, the dominant systematic uncertainty in these limits is due to the uncertainty in the nuclear recoil scintillation efficiency (NRSE) for liquid xenon. The NRSE is defined as the amount of scintillation produced by nuclear recoils, divided by the amount of scintillation produced by electron recoils, per unit energy. Though the NRSE has been measured by several groups, its value at the low energies most important for the liquid xenon WIMP searches has a large uncertainty. Furthermore, the NRSE may vary with the strength of the electric field in the liquid xenon. In an attempt to reduce these uncertainties, we have measured the NRSE down to 5 keV nuclear recoil energy for various electric fields.

  17. Development of a liquid scintillator neutron multiplicity counter (LSMC)

    NASA Astrophysics Data System (ADS)

    Frame, Katherine; Clay, Willam; Elmont, Tim; Esch, Ernst; Karpius, Peter; MacArthur, Duncan; McKigney, Edward; Santi, Peter; Smith, Morag; Thron, Jonathan; Williams, Richard

    2007-08-01

    A new neutron multiplicity counter is being developed that utilizes the fast response of liquid scintillator detectors. The ability to detect fast (vs. moderated) fission neutrons makes possible a coincidence gate of the order of tens of nanoseconds (vs. tens of microseconds). A neutron counter with such a narrow gate will be virtually insensitive to accidental coincidences, making it possible to measure items with a high single neutron background to greater accuracy in less time. This includes impure Pu items with high (α, n) rates as well as items of low-mass HEU where a strong active interrogation source is needed. Liquid scintillator detectors also allow for energy discrimination between interrogation source neutrons and fission neutrons, allowing for even greater assay sensitivity. Designing and building a liquid scintillator multiplicity counter (LSMC) requires a symbiotic effort of simulation and experiment to optimize performance and mitigate hardware costs in the final product. We present preliminary Monte-Carlo studies using the GEANT toolkit.

  18. Measurement of ortho-positronium properties in liquid scintillators

    NASA Astrophysics Data System (ADS)

    Perasso, S.; Consolati, G.; Franco, D.; Jollet, C.; Meregaglia, A.; Tonazzo, A.; Yeh, M.

    2014-03-01

    Pulse shape discrimination is a well-established technique for background rejection in liquid scintillator detectors. It is particularly effective in separating heavy particles from light particles, but not in distinguishing electrons from positrons. This inefficiency can be overtaken by exploiting the formation of ortho-positronium (o-Ps), which alters the time profile of light pulses induced by positrons. We characterized the o-Ps properties in the most commonly used liquid scintillators, i.e. PC, PXE, LAB, OIL and PC + PPO. In addition, we studied the effects of scintillator doping on the o-Ps properties for dopants used in neutrino-less double beta decay experiments (Nd and Te) and in anti-neutrino and neutron detection (Gd and Li respectively). We found that the o-Ps properties are similar in all the tested scintillators, with a lifetime around 3 ns and a formation probability of about 50%. This result indicates that an o-Ps-enhanced pulse shape discrimination can be applied in liquid scintillator detectors for neutrino and anti-neutrino detection and for neutrino-less double beta decay search.

  19. Melt-cast organic glasses as high-efficiency fast neutron scintillators

    DOE PAGESBeta

    Carlson, Joseph S.; Feng, Patrick L.

    2016-06-24

    In this work we report a new class of organic-based scintillators that combines several of the desirable attributes of existing crystalline, liquid, and plastic organic scintillators. The prepared materials may be isolated in single crystalline form or melt-cast to produce highly transparent glasses that have been shown to provide high light yields of up to 16,000 photons/MeVee, as evaluated against EJ-200 plastic scintillators and solution-grown trans-stilbene crystals. The prepared organic glasses exhibit neutron/gamma pulse-shape discrimination (PSD) and are compatible with wavelength shifters to reduce optical self-absorption effects that are intrinsic to pure materials such as crystalline organics. In conclusion, themore » combination of high scintillation efficiency, PSD capabilities, and facile scale-up via melt-casting distinguishes this new class of amorphous materials from existing alternatives.« less

  20. Direct determination of lead-210 by liquid-scintillation counting

    NASA Technical Reports Server (NTRS)

    Fairman, W. D.; Sedlet, J.

    1969-01-01

    Soft betas, the internal conversion electrons, and unconverted gamma rays from lead-210 are efficiently detected in a liquid scintillation counting system with efficiency of 97 percent. The counter is interfaced with a multichannel pulse height analyzer. The spectra obtained is stored on paper tape and plotted on an x-y plotter.

  1. Measurement of Scintillation and Ionization Yield and Scintillation Pulse Shape from Nuclear Recoils in Liquid Argon

    SciTech Connect

    Cao, H.

    2015-05-26

    We have measured the scintillation and ionization yield of recoiling nuclei in liquid argon as a function of applied electric field by exposing a dual-phase liquid argon time projection chamber (LAr-TPC) to a low energy pulsed narrow band neutron beam produced at the Notre Dame Institute for Structure and Nuclear Astrophysics. Liquid scintillation counters were arranged to detect and identify neutrons scattered in the TPC and to select the energy of the recoiling nuclei. We also report measurements of the scintillation yields for nuclear recoils with energies from 10.3 to 57.3 keV and for median applied electric fields from 0 to 970 V/cm. For the ionization yields, we report measurements from 16.9 to 57.3 keV and for electric fields from 96.4 to 486 V/cm. Furthermore, we report the observation of an anticorrelation between scintillation and ionization from nuclear recoils, which is similar to the anticorrelation between scintillation and ionization from electron recoils. Assuming that the energy loss partitions into excitons and ion pairs from 83mKr internal conversion electrons is comparable to that from 207Bi conversion electrons, we obtained the numbers of excitons (Nex) and ion pairs (Ni) and their ratio (Nex/Ni) produced by nuclear recoils from 16.9 to 57.3 keV. Motivated by arguments suggesting direction sensitivity in LAr-TPC signals due to columnar recombination, a comparison of the light and charge yield of recoils parallel and perpendicular to the applied electric field is presented for the first time.

  2. Measurement of Scintillation and Ionization Yield and Scintillation Pulse Shape from Nuclear Recoils in Liquid Argon

    DOE PAGESBeta

    Cao, H.

    2015-05-26

    We have measured the scintillation and ionization yield of recoiling nuclei in liquid argon as a function of applied electric field by exposing a dual-phase liquid argon time projection chamber (LAr-TPC) to a low energy pulsed narrow band neutron beam produced at the Notre Dame Institute for Structure and Nuclear Astrophysics. Liquid scintillation counters were arranged to detect and identify neutrons scattered in the TPC and to select the energy of the recoiling nuclei. We also report measurements of the scintillation yields for nuclear recoils with energies from 10.3 to 57.3 keV and for median applied electric fields from 0more » to 970 V/cm. For the ionization yields, we report measurements from 16.9 to 57.3 keV and for electric fields from 96.4 to 486 V/cm. Furthermore, we report the observation of an anticorrelation between scintillation and ionization from nuclear recoils, which is similar to the anticorrelation between scintillation and ionization from electron recoils. Assuming that the energy loss partitions into excitons and ion pairs from 83mKr internal conversion electrons is comparable to that from 207Bi conversion electrons, we obtained the numbers of excitons (Nex) and ion pairs (Ni) and their ratio (Nex/Ni) produced by nuclear recoils from 16.9 to 57.3 keV. Motivated by arguments suggesting direction sensitivity in LAr-TPC signals due to columnar recombination, a comparison of the light and charge yield of recoils parallel and perpendicular to the applied electric field is presented for the first time.« less

  3. Calculations and measurements of the scintillator-to-water stopping power ratio of liquid scintillators for use in proton radiotherapy

    PubMed Central

    Ingram, W. Scott; Robertson, Daniel; Beddar, Sam

    2015-01-01

    Liquid scintillators are a promising detector for high-resolution three-dimensional proton therapy dosimetry. Because the scintillator comprises both the active volume of the detector and the phantom material, an ideal scintillator will exhibit water equivalence in its radiological properties. One of the most fundamental of these is the scintillator’s stopping power. The objective of this study was to compare calculations and measurements of scintillator-to-water stopping power ratios to evaluate the suitability of the liquid scintillators BC-531 and OptiPhase HiSafe 3 for proton dosimetry. We also measured the relative scintillation output of the two scintillators. Both calculations and measurements show that the linear stopping power of OptiPhase is significantly closer to water than that of BC-531. BC-531 has a somewhat higher scintillation output. OptiPhase can be mixed with water at high concentrations, which further improves its scintillator-to-water stopping power ratio. However, this causes the solution to become cloudy, which has a negative impact on the scintillation output and spatial resolution of the detector. OptiPhase is preferred over BC-531 for proton dosimetry because its density and scintillator-to-water stopping power ratio are more water equivalent. PMID:25705066

  4. Comparing the response of PSD-capable plastic scintillator to standard liquid scintillator

    NASA Astrophysics Data System (ADS)

    Woolf, Richard S.; Hutcheson, Anthony L.; Gwon, Chul; Phlips, Bernard F.; Wulf, Eric A.

    2015-06-01

    This work discusses a test campaign to characterize the response of the recently developed plastic scintillator with pulse shape discrimination (PSD) capabilities (EJ-299-33). PSD is a property exhibited by certain types of scintillating material in which incident stimuli (fast neutrons or γ rays) can be separated by exploiting differences in the scintillation light pulse tail. Detector geometries used were: a 10 cm×10 cm×10 cm cube and a 10-cm diameter×10-cm long cylinder. EJ-301 and EJ-309 liquid scintillators with well-known responses were also tested. The work was conducted at the University of Massachusetts Lowell Van De Graaff accelerator. The facility accelerated protons on a thin Li target to yield quasi-monoenergetic neutrons from the 7Li(p,n)7Be reaction (Q-value: -1.644 MeV). Collimated fast neutrons were obtained by placing detectors behind a neutron spectrometer. Rotating the spectrometer, and thus changing the neutron energy, allowed us to achieve 0.5-3.2 MeV neutrons in 200-300 keV steps. Data were acquired through a flash analog-to-digital converter (ADC) capable of performing digital PSD measurements. By using the PSD technique to separate the neutron events from unwanted γ background, we constructed a pulse height spectrum at each energy. Obtaining a relationship of the relative light output versus energy allowed us to construct the response function for the EJ-299-33 and liquid scintillator. The EJ-299-33 response in terms of electron equivalent energy (Ee.e.) vs. proton equivalent energy (Ep.e.), how it compared with the standard xylene-based EJ-301 (or, NE-213/BC-501 A equivalent) and EJ-309 liquid scintillator response, and how the EJ-301 and EJ-309 compared, are presented. We find that the EJ-299-33 demonstrated a lower light output by up to 40% for <1.0 MeV neutrons; and ranging between a 5-35% reduction for 2.5-3.0 MeV neutrons compared to the EJ-301/309, depending on the scintillator and geometry. Monte Carlo modeling techniques were

  5. Pulse-shape discrimination in NE213 liquid scintillator detectors

    NASA Astrophysics Data System (ADS)

    Cavallaro, M.; Tropea, S.; Agodi, C.; Assié, M.; Azaiez, F.; Boiano, C.; Bondì, M.; Cappuzzello, F.; Carbone, D.; De Napoli, M.; de Séréville, N.; Foti, A.; Linares, R.; Nicolosi, D.; Scarpaci, J. A.

    2013-02-01

    The 16-channel fast stretcher BaFPro module, originally developed for processing signals of Barium Fluoride scintillators, has been modified to make a high performing analog pulse-shape analysis of signals from the NE213 liquid scintillators of the EDEN neutron detector array. The module produces two Gaussian signals, whose amplitudes are proportional to the height of the fast component of the output light and to the total energy deposited into the scintillator, respectively. An in-beam test has been performed at INFN-LNS (Italy) demonstrating a low detection threshold, a good pulse-shape discrimination even at low energies and a wide dynamic range for the measurement of the neutrons energy.

  6. Optical Design Considerations for Efficient Light Collection from Liquid Scintillation Counters

    SciTech Connect

    Bernacki, Bruce E.; Douglas, Matthew; Erchinger, Jennifer L.; Fuller, Erin S.; Keillor, Martin E.; Morley, Shannon M.; Mullen, Crystal A.; Orrell, John L.; Panisko, Mark E.; Warren, Glen A.; Wright, Michael E.

    2015-01-01

    Liquid scintillation counters measure charged particle-emitting radioactive isotopes and are used for environmental studies, nuclear chemistry, and life science. Alpha and beta emissions arising from the material under study interact with the scintillation cocktail to produce light. The prototypical liquid scintillation counter employs low-level photon-counting detectors to measure the arrival of the scintillation light produced as a result of the dissolved material under study interacting with the scintillation cocktail. For reliable operation the counting instrument must convey the scintillation light to the detectors efficiently and predictably. Current best practices employ the use of two or more detectors for coincidence processing to discriminate true scintillation events from background events due to instrumental effects such as photomultiplier tube dark rates, tube flashing, or other light emission not generated in the scintillation cocktail vial. In low background liquid scintillation counters additional attention is paid to shielding the scintillation cocktail from naturally occurring radioactive material (NORM) present in the laboratory and within the instruments construction materials. Low background design is generally at odds with optimal light collection. This study presents the evolution of a light collection design for liquid scintillation counting in a low background shield. The basic approach to achieve both good light collection and a low background measurement is described. The baseline signals arising from the scintillation vial are modeled and methods to efficiently collect scintillation light are presented as part of the development of a customized low-background, high sensitivity liquid scintillation counting system.

  7. Measuring the 14C content in liquid scintillators

    NASA Astrophysics Data System (ADS)

    Enqvist, T.; Barabanov, I. R.; Bezrukov, L. B.; Gangapshev, A. M.; Gavrilyuk, Y. M.; Grishina, V. Yu; Gurentsov, V. I.; Hissa, J.; Joutsenvaara, J.; Kazalov, V. V.; Krokhaleva, S.; Kutuniva, J.; Kuusiniemi, P.; Kuzminov, V. V.; Kurlovich, A. S.; Loo, K.; Lubsandorzhiev, B. K.; Lubsandorzhiev, S.; Morgalyuk, V. P.; Novikova, G. Y.; Pshukov, A. M.; Sinev, V. V.; Słupecki, M.; Trzaska, W. H.; Umerov, Sh I.; Veresnikova, A. V.; Virkajärvi, A.; Yanovich, Y. A.; Zavarzina, V. P.

    2016-05-01

    We are going to perform a series of measurements where the 14C/12 C ratio will be measured from several liquid scintillator samples with a dedicated setup. The setup is designed with the aim of measuring ratios smaller than 10-18. Measurements take place in two underground laboratories: in the Baksan Neutrino Observatory, Russia and in the Pyhäsalmi mine, Finland. In Baksan the measurements started in 2015 and in Pyhäsalmi they start in the beginning of 2015. In order to fully understand the operation of the setup and its background contributions a development of simulation packages has also been started. Low-energy neutrino detection with a liquid scintillator requires that the intrinsic 14C content in the liquid is extremely low. In the Borexino CTF detector at Gran Sasso, Italy the 14C/12C ratio of 2 × 10-18 has been achieved being the lowest 14C concentration ever measured. In principle, the older the oil or gas source that the liquid scintillator is derived of and the deeper it situates, the smaller the 14C/12C ratio is supposed to be. This, however, is not generally the case, and the ratio is probably determined by the U and Th content of the local environment.

  8. Optical properties of quantum-dot-doped liquid scintillators

    PubMed Central

    Aberle, C.; Li, J.J.; Weiss, S.; Winslow, L.

    2014-01-01

    Semiconductor nanoparticles (quantum dots) were studied in the context of liquid scintillator development for upcoming neutrino experiments. The unique optical and chemical properties of quantum dots are particularly promising for the use in neutrinoless double-beta decay experiments. Liquid scintillators for large scale neutrino detectors have to meet specific requirements which are reviewed, highlighting the peculiarities of quantum-dot-doping. In this paper, we report results on laboratory-scale measurements of the attenuation length and the fluorescence properties of three commercial quantum dot samples. The results include absorbance and emission stability measurements, improvement in transparency due to filtering of the quantum dot samples, precipitation tests to isolate the quantum dots from solution and energy transfer studies with quantum dots and the fluorophore PPO. PMID:25392711

  9. The next-generation liquid-scintillator neutrino observatory LENA

    NASA Astrophysics Data System (ADS)

    Wurm, Michael; Beacom, John F.; Bezrukov, Leonid B.; Bick, Daniel; Blümer, Johannes; Choubey, Sandhya; Ciemniak, Christian; D'Angelo, Davide; Dasgupta, Basudeb; Derbin, Alexander; Dighe, Amol; Domogatsky, Grigorij; Dye, Steve; Eliseev, Sergey; Enqvist, Timo; Erykalov, Alexey; von Feilitzsch, Franz; Fiorentini, Gianni; Fischer, Tobias; Göger-Neff, Marianne; Grabmayr, Peter; Hagner, Caren; Hellgartner, Dominikus; Hissa, Johannes; Horiuchi, Shunsaku; Janka, Hans-Thomas; Jaupart, Claude; Jochum, Josef; Kalliokoski, Tuomo; Kayunov, Alexei; Kuusiniemi, Pasi; Lachenmaier, Tobias; Lazanu, Ionel; Learned, John G.; Lewke, Timo; Lombardi, Paolo; Lorenz, Sebastian; Lubsandorzhiev, Bayarto; Ludhova, Livia; Loo, Kai; Maalampi, Jukka; Mantovani, Fabio; Marafini, Michela; Maricic, Jelena; Marrodán Undagoitia, Teresa; McDonough, William F.; Miramonti, Lino; Mirizzi, Alessandro; Meindl, Quirin; Mena, Olga; Möllenberg, Randolph; Muratova, Valentina; Nahnhauer, Rolf; Nesterenko, Dmitry; Novikov, Yuri N.; Nuijten, Guido; Oberauer, Lothar; Pakvasa, Sandip; Palomares-Ruiz, Sergio; Pallavicini, Marco; Pascoli, Silvia; Patzak, Thomas; Peltoniemi, Juha; Potzel, Walter; Räihä, Tomi; Raffelt, Georg G.; Ranucci, Gioacchino; Razzaque, Soebur; Rummukainen, Kari; Sarkamo, Juho; Sinev, Valerij; Spiering, Christian; Stahl, Achim; Thorne, Felicitas; Tippmann, Marc; Tonazzo, Alessandra; Trzaska, Wladyslaw H.; Vergados, John D.; Wiebusch, Christopher; Winter, Jürgen

    2012-06-01

    As part of the European LAGUNA design study on a next-generation neutrino detector, we propose the liquid-scintillator detector LENA (Low Energy Neutrino Astronomy) as a multipurpose neutrino observatory. The outstanding successes of the Borexino and KamLAND experiments demonstrate the large potential of liquid-scintillator detectors in low-energy neutrino physics. Low energy threshold, good energy resolution and efficient background discrimination are inherent to the liquid-scintillator technique. A target mass of 50 kt will offer a substantial increase in detection sensitivity. At low energies, the variety of detection channels available in liquid scintillator will allow for an energy - and flavor-resolved analysis of the neutrino burst emitted by a galactic Supernova. Due to target mass and background conditions, LENA will also be sensitive to the faint signal of the Diffuse Supernova Neutrino Background. Solar metallicity, time-variation in the solar neutrino flux and deviations from MSW-LMA survival probabilities can be investigated based on unprecedented statistics. Low background conditions allow to search for dark matter by observing rare annihilation neutrinos. The large number of events expected for geoneutrinos will give valuable information on the abundances of Uranium and Thorium and their relative ratio in the Earth's crust and mantle. Reactor neutrinos enable a high-precision measurement of solar mixing parameters. A strong radioactive or pion decay-at-rest neutrino source can be placed close to the detector to investigate neutrino oscillations for short distances and sub-MeV to MeV energies. At high energies, LENA will provide a new lifetime limit for the SUSY-favored proton decay mode into kaon and antineutrino, surpassing current experimental limits by about one order of magnitude. Recent studies have demonstrated that a reconstruction of momentum and energy of GeV particles is well feasible in liquid scintillator. Monte Carlo studies on the

  10. New Efficient Organic Scintillators Derived from Pyrazoline.

    PubMed

    Bliznyuk, Valery N; Seliman, Ayman F; Ishchenko, Alexander A; Derevyanko, Nadezhda A; DeVol, Timothy A

    2016-05-25

    We report on the synthesis, spectroscopic and scintillation properties of three new pyrazoline core based fluorophores. Fluorescence properties of the fluorophores have been studied both in a solution state and in a solid polyvinyltoluene (PVT) resin matrix of different porosity. The synthesized fluorophores were found to be promising candidates for application in plastic scintillators for detection of ionizing radiation (alpha, beta particles, γ rays and neutrons) and demonstrated superior efficiency in comparison to the existing commercially used fluorophores (2-(1-naphthyl)-5-phenyloxazole (αNPO), 9,10-diphenylanthracene, etc.). Moreover, the suggested synthetic route allows functionalization of the fluorophores with a vinyl group for further covalent bound to the PVT or other vinyl polymer matrices, which dramatically improves chemical stability of the system simultaneously improving the photoluminescence quantum yield. Possible mechanisms of the enhanced scintillation properties are discussed based on preliminary quantum mechanical calculations and spectroscopic characteristics of the fluorophores under study. PMID:27163887

  11. Comparison of plastic scintillating fibres and capillaries filled with liquid scintillator

    NASA Astrophysics Data System (ADS)

    Cardini, A.; Cavasinni, V.; Di Girolamo, B.; Flaminio, V.; Golovkin, S. V.; Gorin, A. M.; Kulichenko, A. V.; Kushnirenko, A. E.; Pyshev, A. I.; Manuilov, I.; Vasilchenko, V. G.

    1994-07-01

    A comparison is made between the light yield, attenuation length, time response and light propagation speed in plastic scintillating fibres (SCSF-38 and Kuraray-3HF) and quartz capillaries filled with liquid scintillator (LS) 1-methilnaphthalene (1MN) doped with new dyes R45 and R39. The inner diameter of capillaries and diameter of plastic fibres is 0.5 mm. The number of photoelectrons detected at the far end (2 m) was 2.9 for capillaries filled with 1MN + 3 g/1 R45 while it was 1.8 times smaller in the case of SCSF-38 and 3 times smaller in the case of Kuraray 3HF plastic fibres. Taking into account the quantum efficiency of the photodetector used these reduction factors became 3.0 and 2.0, respectively. Good attenuation length, high light output and also excellent radiation resistance of capillaries filled with LS (> 60 Mrad, measured elsewhere) show that they are a very promising alternative to plastic scintillating fibres for future applications in tracking detectors and calorimeters.

  12. Real-time aqueous tritium monitor using liquid scintillation counting

    SciTech Connect

    Sigg, R.A.; McCarty, J.E.; Livingston, R.R.; Sanders, M.A.

    1994-07-01

    An ability to continuously monitor low-level tritium releases in aqueous effluents is of particular interest to heavy water facilities such as those at the Savannah River Site (SRS) and Canadian CANDU reactors. SRS developed a real-time monitoring system based on flow-through liquid scintillation (LS) counting. Sensitivities of 16 pCi/mL and 1 pCi/mL result from five minute and daily averages of counting data respectively. This sensitivity is about 200 times better than similar methods using solid scintillants. The LS system features uncomplicated sample pretreatment, precise of the cocktail and sample water, system features uncomplicated sample pretreatment, precise proportioning of the cocktail and sample water, on-line quench corrections, cocktail consumption as low as 0.15 mL/min, and response to changes in environmental tritium is less than 30 minutes. Field tests demonstrate that conditions necessary for stable analytical results are achieved.

  13. Detecting energy dependent neutron capture distributions in a liquid scintillator

    NASA Astrophysics Data System (ADS)

    Balmer, Matthew J. I.; Gamage, Kelum A. A.; Taylor, Graeme C.

    2015-03-01

    A novel technique is being developed to estimate the effective dose of a neutron field based on the distribution of neutron captures in a scintillator. Using Monte Carlo techniques, a number of monoenergetic neutron source energies and locations were modelled and their neutron capture response was recorded. Using back propagation Artificial Neural Networks (ANN) the energy and incident direction of the neutron field was predicted from the distribution of neutron captures within a 6Li-loaded liquid scintillator. Using this proposed technique, the effective dose of 252Cf, 241AmBe and 241AmLi neutron fields was estimated to within 30% for four perpendicular angles in the horizontal plane. Initial theoretical investigations show that this technique holds some promise for real-time estimation of the effective dose of a neutron field.

  14. Neutrino Flavor Sensitivity of Large Liquid Scintillator Detectors

    NASA Astrophysics Data System (ADS)

    Loo, K. K.; Bick, D.; Enqvist, T.; Hellgartner, D.; Kaiser, M.; Lorenz, S.; Meloni, M.; Meyer, M.; Möllenberg, R.; Oberauer, L.; Soiron, M.; Smirnov, M.; Stahl, A.; Trzaska, W. H.; Wonsak, B.; Wurm, M.

    Scintillator detectors are known for their good light yield, energy resolution, timing characteristics and pulse shape discrimination capabilities. These features make the next-generation liquid scintillation detector LENA[1] (Low Energy Neutrino Astronomy) the optimal choice for a wide range of astro-particle topics including supernova-, solar-, and geo neutrinos. In addition to the excellent calorimetric and timing properties, scintillartor detectors (LSDs) are also capable of topology reconstruction sufficient to discriminate with adequate efficiency between electron and muon neutrino induced charge current events and neutral current events in the GeV energy range. This feature makes LENA a competitive tool for the determination of the mass hierarchy (MH) with long baseline neutrino beams such as the proposed CN2PY beam (2288 km). This work summarizes the status of the current work on track reconstruction schemes and discusses the sensitivity limit for the neutrino mass hierarchy measurement with LENA.

  15. Improvements in apparatus and procedures for using an organic liquid scintillator as a fast-neutron spectrometer for radiation protection applications

    SciTech Connect

    Thorngate, J.H.

    1987-05-15

    For use in radiation protection measurements, a neutron spectrometer must have a wide energy range, good sensitivity, medium resolution, and ease of taking and reducing data. No single spectrometer meets all of these requirements. Several experiments aimed at improving and characterizing the detector response to gamma rays and neutrons were conducted. A light pipe (25 mm) was needed between the scintillator cell and the photomultiplier tube to achieve the best resolution. The light output of the scintillator as a function of gamma-ray energy was measured. Three experiments were conducted to determine the light output as a function of neutron energy. Monte Carlo calculations were made to evaluate the effects of multiple neutron scattering and edge effects in the detector. The electronic systems associated with the detector were improved with a transistorized circuit providing the bias voltage for the photomultiplier tube dynodes. This circuit was needed to obtain pulse-height linearity over the wide range of signal sizes. A special live-time clock was built to compensate for the large amount of dead time generated by the pulse-shape discrimination circuit we chose to use. 64 refs., 58 figs., 9 tabs.

  16. Simulation results of liquid and plastic scintillator detectors for reactor antineutrino detection - A comparison

    NASA Astrophysics Data System (ADS)

    Kashyap, V. K. S.; Pant, L. M.; Mohanty, A. K.; Datar, V. M.

    2016-03-01

    A simulation study of two kinds of scintillation detectors has been done using GEANT4. We compare plastic scintillator and liquid scintillator based designs for detecting electron antineutrinos emitted from the core of reactors. The motivation for this study is to set up an experiment at the research reactor facility at BARC for very short baseline neutrino oscillation study and remote reactor monitoring.

  17. Optical design considerations for efficient light collection from liquid scintillation counters.

    PubMed

    Bernacki, Bruce E; Douglas, Matthew; Erchinger, Jennifer L; Fuller, Erin S; Keillor, Martin E; Morley, Shannon M; Mullen, Crystal A; Orrell, John L; Panisko, Mark E; Warren, Glen A; Wright, Michael E

    2015-03-20

    Liquid scintillation counters measure charged particle-emitting radioactive isotopes and are used for environmental studies, nuclear chemistry, and life science. Alpha and beta emissions arising from the material under study interact with the scintillation cocktail to produce light. The prototypical liquid scintillation counter employs low-level photon-counting detectors to measure the arrival of the scintillation. For reliable operation, the counting instrument must convey the scintillation light to the detectors efficiently and predictably. Current best practices employ the use of two or more detectors for coincidence processing to discriminate true scintillation events from background events due to instrumental effects such as photomultiplier tube dark rates, tube flashing, or other light emission not generated in the scintillation cocktail vial. In low-background liquid scintillation counters, additional attention is paid to shielding the scintillation cocktail from naturally occurring radioactive material present in the laboratory and within the instrument's construction materials. Low-background design is generally at odds with optimal light collection. This study presents the evolution of a light collection design for liquid scintillation counting (LSC) in a low-background shield. The basic approach to achieve both good light collection and a low-background measurement is described. The baseline signals arising from the scintillation vial are modeled and methods to efficiently collect scintillation light are presented as part of the development of a customized low-background, high-sensitivity LSC system. PMID:25968530

  18. A study of liquid scintillator and fiber materials for use in a fiber calorimeter

    SciTech Connect

    Altice, P.P. Jr.

    1990-04-01

    This reports an investigation into the performance of selected scintillation oils and fiber materials to test their applicability in high energy, liquid scintillator calorimetry. Two scintillating oils, Bicron BC-517 and an oil mixed for the MACRO experiment, and two fiber materials, Teflon and GlassClad PS-252, were tested for the following properties: light yield, attenuation length and internal reflection angle. The results of these tests indicated that the scintillation oils and the fiber materials had an overall good performance with lower energies and would meet the requirements of liquid scintillator detection at SSC energies. 6 refs.

  19. N-(2-Ethylhexyl)carbazole: A New Fluorophore Highly Suitable as a Monomolecular Liquid Scintillator.

    PubMed

    Montbarbon, Eva; Sguerra, Fabien; Bertrand, Guillaume H V; Magnier, Élodie; Coulon, Romain; Pansu, Robert B; Hamel, Matthieu

    2016-08-16

    The synthesis, photophysical properties, and applications in scintillation counting of N-(2-ethylhexyl)carbazole (EHCz) are reported. This molecule displays all of the required characteristics for an efficient liquid scintillator (emission wavelength, scintillation yield), and can be used without any extra fluorophores. Thus, its scintillation properties are discussed, as well as its fast neutron/gamma discrimination. For the latter application, the material is compared with the traditional liquid scintillator BC-501 A, and other liquid fluorescent molecules classically used as scintillation solvents, such as xylene, pseudocumene (PC), linear alkylbenzenes (LAB), diisopropylnaphthalene (DIN), 1-methylnaphthalene (1-MeNapht), and 4-isopropylbiphenyl (iPrBiph). For the first time, an excimeric form of a molecule has been advantageously used in scintillation counting. A moderate discrimination between fast neutrons and gamma rays was observed in bulk EHCz, with an apparent neutron/gamma discrimination potential half of that of BC-501 A. PMID:27406840

  20. Fast neutron spectrometry with organic scintillators applied to magnetic fusion experiments

    NASA Astrophysics Data System (ADS)

    Kaschuck, Yu. A.; Esposito, B.; Trykov, L. A.; Semenov, V. P.

    2002-01-01

    Neutron spectrometry with NE213 liquid scintillators is commonly used in thermonuclear fusion experiments to measure the 2.45 and 14.1 MeV neutron flux. We present the unfolded neutron spectrum, which was accumulated during several ohmic deuterium plasma discharges in the Frascati Tokamak Upgrade using a 2″×2″ NE213 scintillator. In this paper, we review the application of organic scintillator neutron spectrometers to tokamaks, focusing in particular on the comparison between NE213 and stilbene scintillators. Various aspects of the calibration technique and neutron spectra unfolding procedure are considered in the context of their application for fusion neutron spectrometry. Testing and calibration measurements have been carried out using D-D and D-T neutron generator facilities with both NE213 and stilbene scintillators. The main result from these measurements is that stilbene scintillator has better neutron energy resolution than NE213. Our stilbene detector could be used for the determination of the ion temperature ( Ti) from neutron spectrum broadening in tokamak thermonuclear plasmas with Ti=4 keV and higher.

  1. ARAPUCA a new device for liquid argon scintillation light detection

    NASA Astrophysics Data System (ADS)

    Machado, A. A.; Segreto, E.

    2016-02-01

    We present a totally innovative device for the detection of liquid argon scintillation light, that has been named ARAPUCA (Argon R&D Advanced Program at UniCAmp). It is composed of a passive light collector and of active devices. The latters are standard SiPMs that operate at liquid argon temperature, while the passive collector is based on a new technology, never explored in this field before. It is a photon trap, that allows to collect light with extremely high efficiency. The total detection efficiency of the device can be tuned by modifying the ratio between the area of the active devices (SiPM) and the area of the optical window. For example, it will allow to reach a detection efficiency at the level of 1% on a surface of 50 × 50 cm2 with an active coverage of 2 × 2 cm2 (two/three large area SiPM). It is also a cheap device, since the major part of its cost is represented by the active devices. For these reason this appears to be the ideal device for scintillation light detection in large Time Projection Chambers. With appropriate modifications it can be used also in next generation Dark Matter detectors.

  2. The IFIN-HH triple coincidence liquid scintillation counter.

    PubMed

    Razdolescu, A C; Broda, R; Cassette, P; Simpson, B R S; Van Wyngaardt, W M

    2006-01-01

    The paper summarizes the IFIN-HH triple coincidence liquid scintillation counter used for the implementation of the TDCR method. The electronic unit was recently extended to record the three individual double coincidence ratios to take into account the differences in the quantum efficiencies of the three-photomultiplier tubes. Some details of the electronic system and the data processing are given. The critical point of a TDCR counter is to adjust correctly the discriminator levels on the three channels under the single electron peak. The paper describes the method of adjustment based on the evolution of the dark counting rate versus the discriminator level. Also indicated is the influence of the discrimination level on the activity results as measured at IFIN-HH using a 3H standard. The performances of the IFIN-HH TDCR counter was checked against the measurement results of the TDCR counters of CSIR NML (South Africa), RC (Poland) and LNHB (France). A set of ready-to-measure 63Ni sources in liquid scintillator, in sealed counting vials, was prepared and dispatched for measurement to all these laboratories. The paper describes designs of the TDCR counters used. An analysis and discussion of the measurement results is given. PMID:16563781

  3. Spectroscopic study of light scattering in linear alkylbenzene for liquid scintillator neutrino detectors

    NASA Astrophysics Data System (ADS)

    Zhou, Xiang; Liu, Qian; Han, Junbo; Zhang, Zhenyu; Zhang, Xuan; Ding, Yayun; Zheng, Yangheng; Zhou, Li; Cao, Jun; Wang, Yifang

    2015-11-01

    We have set up a light scattering spectrometer to study the depolarization of light scattering in linear alkylbenzene. The scattering spectra show that the depolarized part of light scattering is due to Rayleigh scattering. The additional depolarized Rayleigh scattering can make the effective transparency of linear alkylbenzene much better than expected. Therefore, sufficient scintillation photons can transmit through large liquid scintillator detector, such as that of the JUNO experiment. Our study is crucial to achieving an unprecedented energy resolution of 3 %/√{E{(MeV)}} required for the JUNO experiment to determine the neutrino mass hierarchy. The spectroscopic method can also be used to examine the depolarization of other organic solvents used in neutrino experiments.

  4. Scintillation Light from Cosmic-Ray Muons in Liquid Argon

    SciTech Connect

    Whittington, Denver Wade; Mufson, S.; Howard, B.

    2015-11-13

    This paper reports the results of an experiment to directly measure the time-resolved scintillation signal from the passage of cosmic-ray muons through liquid argon. Scintillation light from these muons is of value to studies of weakly-interacting particles in neutrino experiments and dark matter searches. The experiment was carried out at the TallBo dewar facility at Fermilab using prototype light guide detectors and electronics developed for the Deep Underground Neutrino Experiment. Two models are presented for the time structure of the scintillation light, a phenomenological model and a physically-motivated model. Both models find tT = 1:52 ms for the decay time constant of the Ar 2 triplet state. These models also show that the identification of the “early” light fraction in the phenomenological model, FE 25% of the signal, with the total light from singlet decays is an underestimate. The total fraction of singlet light is FS 36%, where the increase over FE is from singlet light emitted by the wavelength shifter through processes with long decay constants. The models were further used to compute the experimental particle identification parameter Fprompt, the fraction of light coming in a short time window after the trigger compared with the light in the total recorded waveform. The models reproduce quite well the typical experimental value 0.3 found by dark matter and double b-decay experiments, which suggests this parameter provides a robust metric for discriminating electrons and muons from more heavily ionizing particles.

  5. Scintillation light from cosmic-ray muons in liquid argon

    NASA Astrophysics Data System (ADS)

    Whittington, D.; Mufson, S.; Howard, B.

    2016-05-01

    This paper reports the results of an experiment to directly measure the time-resolved scintillation signal from the passage of cosmic-ray muons through liquid argon. Scintillation light from these muons is of value to studies of weakly-interacting particles in neutrino experiments and dark matter searches. The experiment was carried out at the TallBo dewar facility at Fermilab using prototype light guide detectors and electronics developed for the Deep Underground Neutrino Experiment. Two models are presented for the time structure of the scintillation light, a phenomenological model and a composite model. Both models find τT = 1.52 μs for the decay time constant of the Ar2* triplet state. These models also show that the identification of the ``early'' light fraction in the phenomenological model, FE ≈ 25% of the signal, with the total light from singlet decays is an underestimate. The total fraction of singlet light is FS ≈ 36%, where the increase over FE is from singlet light emitted by the wavelength shifter through processes with long decay constants. The models were further used to compute the experimental particle identification parameter Fprompt, the fraction of light coming in a short time window after the trigger compared with the light in the total recorded waveform. The models reproduce quite well the typical experimental value ~0.3 found by dark matter and double β-decay experiments, which suggests this parameter provides a robust metric for discriminating electrons and muons from more heavily ionizing particles.

  6. Optimization of screening for radioactivity in urine by liquid scintillation.

    SciTech Connect

    Shanks, Sonoya Toyoko; Reese, Robert P.; Preston, Rose T.

    2007-08-01

    Numerous events have or could have resulted in the inadvertent uptake of radionuclides by fairly large populations. Should a population receive an uptake, valuable information could be obtained by using liquid scintillation counting (LSC) techniques to quickly screen urine from a sample of the affected population. This study investigates such LSC parameters as discrimination, quench, volume, and count time to yield guidelines for analyzing urine in an emergency situation. Through analyzing variations of the volume and their relationships to the minimum detectable activity (MDA), the optimum ratio of sample size to scintillating chemical cocktail was found to be 1:3. Using this optimum volume size, the alpha MDA varied from 2100 pCi/L for a 30-second count time to 35 pCi/L for a 1000-minute count time. The typical count time used by the Sandia National Laboratories Radiation Protection Sample Diagnostics program is 30 minutes, which yields an alpha MDA of 200 pCi/L. Because MDA is inversely proportional to the square root of the count time, count time can be reduced in an emergency situation to achieve the desired MDA or response time. Note that approximately 25% of the response time is used to prepare the samples and complete the associated paperwork. It was also found that if the nuclide of interest is an unknown, pregenerated discriminator settings and efficiency calibrations can be used to produce an activity value within a factor of two, which is acceptable for a screening method.

  7. Fast-neutron multiplicity analysis based on liquid scintillation.

    PubMed

    Li, Sufen; Qiu, Suizheng; Zhang, Quanhu; Huo, Yonggang; Lin, Hongtao

    2016-04-01

    In this study, according to the establishment of the classical neutron multiplicity measurement equation, a fast-neutron multiplicity analysis and measurement equation is established, considering the influence of neutron scattering cross-talk, by means of theoretical analysis and computer simulation. Moreover, the fission rate F, multiplication M, and (α, n) reaction rate α in the established equation were solved. A new measurement method of scattering cross-talk was established and the established equation was validated using Geant4 simulation. The fast-neutron multiplicity counting equation has only a smaller deviation from the fast-neutron multiplicity counting system based on liquid scintillation detector, and it has a wider application prospect. PMID:26766037

  8. Quality assurance manual plutonium liquid scintillation methods and procedures

    SciTech Connect

    Romero, L.

    1997-01-01

    Nose swipe analysis is a very important tool for Radiation Protection personnel. Nose swipe analysis is a very fast and accurate method for (1) determining if a worker has been exposed to airborne plutonium contamination and (2) Identifying the area where there has been a possible plutonium release. Liquid scintillation analysis techniques have been effectively applied to accurately determine the plutonium alpha activity on nose swipe media. Whatman-40 paper and Q-Tips are the only two media which have been evaluated and can be used for nose swipe analysis. Presently, only Q-Tips are used by Group HSE-1 Radiation Protection Personnel. However, both swipe media will be discussed in this report.

  9. Optimization of Pulse Shape Discrimination of PROSPECT Liquid Scintillator Signals

    NASA Astrophysics Data System (ADS)

    Han, Ke; Prospect Collaboration

    2015-04-01

    PROSPECT, A Precision Oscillation and Spectrum Experiment, will use a segmented Li-6 doped liquid scintillator detector for precision measurement of the reactor anti-neutrino spectrum at the High Flux Isotope Reactor at Oak Ridge National Laboratory. PROSPECT also searches for very short baseline neutrino oscillation, an indication of the existence of eV-scale sterile neutrinos. Pulse shape analysis of the prompt anti-neutino signal and delayed neutron capture on Li-6 signal will greatly suppress background sources such as fast neutrons and accidental coincidence of gammas. In this talk, I will discuss different pulse shape parameters used in PROSPECT prototype detectors and multivariate optimization of event selection cuts based on those parameters.

  10. Showering cosmogenic muons in a large liquid scintillator

    NASA Astrophysics Data System (ADS)

    Grassi, Marco; Evslin, Jarah; Ciuffoli, Emilio; Zhang, Xinmin

    2014-09-01

    We present the results of FLUKA simulations of the propagation of cosmogenic muons in a 20 kton spherical liquid scintillator detector underneath 700 to 900 meters of rock. A showering muon is one which deposits at least 3 GeV in the detector in addition to ionization energy. We find that 20 percent of muons are showering and a further 11 percent of muon events are muon bundles, of which more than one muon enters the detector. In this range the showering and bundle fractions are robust against changes in the depth and topography, thus the total shower and bundle rate for a given experiment can be obtained by combining our results with an estimate for the total muon flux. One consequence is that a straightforward adaptation of the full detector showering muon cuts used by KamLAND to JUNO or RENO 50 would yield a nearly vanishing detector efficiency.

  11. Characterization and Modeling of a Water-based Liquid Scintillator

    SciTech Connect

    L. J. Bignell; Beznosko, D.; Diwan, M. V.; Hans, S.; Jaffe, D. E.; S. Kettell; Rosero, R.; Themann, H. W.; Viren, B.; Worcester, E.; Yeh, M.; Zhang, C.

    2015-12-15

    We characterised Water-based Liquid Scintillator (WbLS) using low energy protons, UV-VIS absorbance, and fluorescence spectroscopy. We have also developed and validated a simulation model that describes the behaviour of WbLS in our detector configurations for proton beam energies of 210 MeV, 475 MeV, and 2 GeV and for two WbLS compositions. These results have enabled us to estimate the light yield and ionisation quenching of WbLS, as well as to understand the influence of the wavelength shifting of Cherenkov light on our measurements. These results are relevant to the suitability of WbLS materials for next generation intensity frontier experiments.

  12. A step toward CNO solar neutrino detection in liquid scintillators

    NASA Astrophysics Data System (ADS)

    Villante, F. L.; Ianni, A.; Lombardi, F.; Pagliaroli, G.; Vissani, F.

    2011-07-01

    The detection of CNO solar neutrinos in ultrapure liquid scintillator detectors is limited by the background produced by bismuth-210 nuclei that undergo β-decay to polonium-210 with a lifetime of ˜7 days. Polonium-210 nuclei are unstable and decay with a lifetime equal to ˜200 days emitting α particles that can be also detected. In this Letter, we show that the Bi-210 background can be determined by looking at the time evolution of α-decay rate of Po-210, provided that α particle detection efficiency is stable over the data acquisition period and external sources of Po-210 are negligible. A sufficient accuracy can be obtained in a relatively short time. As an example, if the initial Po-210 event rate is ˜2000 cpd/100 ton or lower, a Borexino-like detector could start discerning CNO neutrino signal from Bi-210 background in Δt˜1 yr.

  13. Measuring fast neutrons with large liquid scintillation detector for ultra-low background experiments

    NASA Astrophysics Data System (ADS)

    Zhang, C.; Mei, D.-M.; Davis, P.; Woltman, B.; Gray, F.

    2013-11-01

    We developed a 12-liter volume neutron detector filled with the liquid scintillator EJ301 that measures neutrons in an underground laboratory where dark matter and neutrino experiments are located. The detector target is a cylindrical volume coated on the inside with reflective paint (95% reflectivity) that significantly increases the detector's light collection. We demonstrate several calibration techniques using point sources and cosmic-ray muons for energies up to 20 MeV for this large liquid scintillation detector. Neutron-gamma separation using pulse shape discrimination with a few MeV neutrons to hundreds of MeV neutrons is shown for the first time using a large liquid scintillator.

  14. Application of scintillating properties of liquid xenon and silicon photomultiplier technology to medical imaging

    NASA Astrophysics Data System (ADS)

    Gomez-Cadenas, J. J.; Benlloch-Rodriguez, J. M.; Ferrario, Paola

    2016-04-01

    We describe a new positron emission time-of-flight apparatus using liquid xenon. The detector is based in a liquid xenon scintillating cell. The cell shape and dimensions can be optimized depending on the intended application. In its simplest form, the liquid xenon scintillating cell is a box in which two faces are covered by silicon photomultipliers and the others by a reflecting material such as Teflon. It is a compact, homogenous and highly efficient detector which shares many of the desirable properties of monolithic crystals, with the added advantage of high yield and fast scintillation offered by liquid xenon. Our initial studies suggest that good energy and spatial resolution comparable with that achieved by lutetium oxyorthosilicate crystals can be obtained with a detector based in liquid xenon scintillating cells. In addition, the system can potentially achieve an excellent coincidence resolving time of better than 100 ps.

  15. Liquid argon scintillation read-out with silicon devices

    NASA Astrophysics Data System (ADS)

    Canci, N.; Cattadori, C.; D'Incecco, M.; Lehnert, B.; Machado, A. A.; Riboldi, S.; Sablone, D.; Segreto, E.; Vignoli, C.

    2013-10-01

    Silicon photosensors represent a viable alternative to standard photomultipliers in fields such as communications and medical imaging. We explored the interesting possibility of using these sensors in combination with liquid argon (LAr) for astroparticle physics applications such as neutrino, dark matter and double beta decay experiments. In fact, silicon photosensors have detection efficiencies comparable with those of the highest performance PMTs and can be manufactured with high level of radiopurity. In particular within the on-going R&D activity of the SILENT project (Low background and low noise techniques for double beta decay physics funded by ASPERA) a large area SiPM (Silicon PhotoMultiplier - Hamamatsu S11828-3344M - 1.7 cm2 area) has been installed in a LAr scintillation chamber of 0.5 liters volume together with a cryogenic photomultiplier tube (Hamamatsu R11065) used as a reference. The liquid argon chamber has been exposed to many gamma sources of different energies and single photoelectron response and light yield for the SiPM and PMT have been measured and compared. In this contribution the results of the tests, and the ongoing R&D to optimize the SiPM for cryogenic and for ultralow background applications, are reported, as well as the possible application in the GERDA experiment on Double Beta Decay Searches of 76Ge.

  16. Tomographic analysis of neutron and gamma pulse shape distributions from liquid scintillation detectors at Joint European Torus

    SciTech Connect

    Giacomelli, L.; Conroy, S.; Gorini, G.; Horton, L.; Murari, A.; Popovichev, S.; Syme, D. B.

    2014-02-15

    The Joint European Torus (JET, Culham, UK) is the largest tokamak in the world devoted to nuclear fusion experiments of magnetic confined Deuterium (D)/Deuterium-Tritium (DT) plasmas. Neutrons produced in these plasmas are measured using various types of neutron detectors and spectrometers. Two of these instruments on JET make use of organic liquid scintillator detectors. The neutron emission profile monitor implements 19 liquid scintillation counters to detect the 2.45 MeV neutron emission from D plasmas. A new compact neutron spectrometer is operational at JET since 2010 to measure the neutron energy spectra from both D and DT plasmas. Liquid scintillation detectors are sensitive to both neutron and gamma radiation but give light responses of different decay time such that pulse shape discrimination techniques can be applied to identify the neutron contribution of interest from the data. The most common technique consists of integrating the radiation pulse shapes within different ranges of their rising and/or trailing edges. In this article, a step forward in this type of analysis is presented. The method applies a tomographic analysis of the 3-dimensional neutron and gamma pulse shape and pulse height distribution data obtained from liquid scintillation detectors such that n/γ discrimination can be improved to lower energies and additional information can be gained on neutron contributions to the gamma events and vice versa.

  17. Tomographic analysis of neutron and gamma pulse shape distributions from liquid scintillation detectors at Joint European Torus

    NASA Astrophysics Data System (ADS)

    Giacomelli, L.; Conroy, S.; Gorini, G.; Horton, L.; Murari, A.; Popovichev, S.; Syme, D. B.

    2014-02-01

    The Joint European Torus (JET, Culham, UK) is the largest tokamak in the world devoted to nuclear fusion experiments of magnetic confined Deuterium (D)/Deuterium-Tritium (DT) plasmas. Neutrons produced in these plasmas are measured using various types of neutron detectors and spectrometers. Two of these instruments on JET make use of organic liquid scintillator detectors. The neutron emission profile monitor implements 19 liquid scintillation counters to detect the 2.45 MeV neutron emission from D plasmas. A new compact neutron spectrometer is operational at JET since 2010 to measure the neutron energy spectra from both D and DT plasmas. Liquid scintillation detectors are sensitive to both neutron and gamma radiation but give light responses of different decay time such that pulse shape discrimination techniques can be applied to identify the neutron contribution of interest from the data. The most common technique consists of integrating the radiation pulse shapes within different ranges of their rising and/or trailing edges. In this article, a step forward in this type of analysis is presented. The method applies a tomographic analysis of the 3-dimensional neutron and gamma pulse shape and pulse height distribution data obtained from liquid scintillation detectors such that n/γ discrimination can be improved to lower energies and additional information can be gained on neutron contributions to the gamma events and vice versa.

  18. Organic scintillator detector response simulations with DRiFT

    NASA Astrophysics Data System (ADS)

    Andrews, M. T.; Bates, C. R.; McKigney, E. A.; Solomon, C. J.; Sood, A.

    2016-09-01

    This work presents the organic scintillation simulation capabilities of DRiFT, a post-processing Detector Response Function Toolkit for MCNP® output. DRiFT is used to create realistic scintillation detector response functions to incident neutron and gamma mixed-field radiation. As a post-processing tool, DRiFT leverages the extensively validated radiation transport capabilities of MCNP® 6 , which also provides the ability to simulate complex sources and geometries. DRiFT is designed to be flexible, it allows the user to specify scintillator material, PMT type, applied PMT voltage, and quenching data used in simulations. The toolkit's capabilities, which include the generation of pulse shape discrimination plots and full-energy detector spectra, are demonstrated in a comparison of measured and simulated neutron contributions from 252Cf and PuBe, and photon spectra from 22Na and 228Th sources. DRiFT reproduced energy resolution effects observed in EJ-301 measurements through the inclusion of scintillation yield variances, photon transport noise, and PMT photocathode and multiplication noise.

  19. Non-toxic liquid scintillators with high light output based on phenyl-substituted siloxanes

    NASA Astrophysics Data System (ADS)

    Dalla Palma, M.; Carturan, S. M.; Degerlier, M.; Marchi, T.; Cinausero, M.; Gramegna, F.; Quaranta, A.

    2015-04-01

    The work describes the development of a new class of liquid scintillators based on polysiloxane liquid compounds. These materials are characterized by low toxicity, chemical inertness, very low volatility and low flammability, allowing their use without concerns even at high temperatures in vacuum. In this view different polysiloxane based liquids have been tested, with variable content and distribution of phenyl lateral substituents and added with suitable dyes, namely 2,5-diphenyloxazole (PPO) and Lumogen Violet (LV). Absorption and fluorescence spectroscopy have been used in order to study the emission feature of the various compounds and to investigate the spectral matching between siloxane solvents and dissolved primary dyes. Scintillation efficiency towards 60Co and 137Cs gamma rays, relative to commercial liquid scintillator (EJ-309), has been measured and the results have been related to the energy transfer and energy migration mechanism from monomer and excimer forming sites in liquid siloxanes.

  20. Method for measuring multiple scattering corrections between liquid scintillators

    DOE PAGESBeta

    Verbeke, J. M.; Glenn, A. M.; Keefer, G. J.; Wurtz, R. E.

    2016-04-11

    In this study, a time-of-flight method is proposed to experimentally quantify the fractions of neutrons scattering between scintillators. An array of scintillators is characterized in terms of crosstalk with this method by measuring a californium source, for different neutron energy thresholds. The spectral information recorded by the scintillators can be used to estimate the fractions of neutrons multiple scattering. With the help of a correction to Feynman's point model theory to account for multiple scattering, these fractions can in turn improve the mass reconstruction of fissile materials under investigation.

  1. Method for measuring multiple scattering corrections between liquid scintillators

    NASA Astrophysics Data System (ADS)

    Verbeke, J. M.; Glenn, A. M.; Keefer, G. J.; Wurtz, R. E.

    2016-07-01

    A time-of-flight method is proposed to experimentally quantify the fractions of neutrons scattering between scintillators. An array of scintillators is characterized in terms of crosstalk with this method by measuring a californium source, for different neutron energy thresholds. The spectral information recorded by the scintillators can be used to estimate the fractions of neutrons multiple scattering. With the help of a correction to Feynman's point model theory to account for multiple scattering, these fractions can in turn improve the mass reconstruction of fissile materials under investigation.

  2. Combustion water purification techniques influence on OBT analysing using liquid scintillation counting method

    SciTech Connect

    Varlam, C.; Vagner, I.; Faurescu, I.; Faurescu, D.

    2015-03-15

    In order to determine organically bound tritium (OBT) from environmental samples, these must be converted into water, measurable by liquid scintillation counting (LSC). For this purpose we conducted some experiments to determine OBT level of a grass sample collected from an uncontaminated area. The studied grass sample was combusted in a Parr bomb. However usual interfering phenomena were identified: color or chemical quench, chemiluminescence, overlap over tritium spectrum because of other radionuclides presence as impurities ({sup 14}C from organically compounds, {sup 36}Cl as chloride and free chlorine, {sup 40}K as potassium cations) and emulsion separation. So the purification of the combustion water before scintillation counting appeared to be essential. 5 purification methods were tested: distillation with chemical treatment (Na{sub 2}O{sub 2} and KMnO{sub 4}), lyophilization, chemical treatment (Na{sub 2}O{sub 2} and KMnO{sub 4}) followed by lyophilization, azeotropic distillation with toluene and treatment with a volcanic tuff followed by lyophilization. After the purification step each sample was measured and the OBT measured concentration, together with physico-chemical analysis of the water analyzed, revealed that the most efficient method applied for purification of the combustion water was the method using chemical treatment followed by lyophilization.

  3. Passive Measurement of Organic-Scintillator Neutron Signatures for Nuclear Safeguards Applications

    SciTech Connect

    Jennfier L. Dolan; Eric C. Miller; Alexis C. Kaplan; Andreas Enqvist; Marek Flaska; Alice Tomanin; Paolo Peerani; David L. Chichester; Sara A. Pozzi

    2012-10-01

    At nuclear facilities, domestically and internationally, most measurement systems used for nuclear materials’ control and accountability rely on He-3 detectors. Due to resource shortages, alternatives to He-3 systems are needed. This paper presents preliminary simulation and experimental efforts to develop a fast-neutron-multiplicity counter based on liquid organic scintillators. This mission also provides the opportunity to broaden the capabilities of such safeguards measurement systems to improve current neutron-multiplicity techniques and expand the scope to encompass advanced nuclear fuels.

  4. Monte Carlo and Analytical Models of Neutron Detection with Organic Scintillation Detectors

    SciTech Connect

    Pozzi, Sara A; Flaska, Marek; Enqvist, Andreas; Pazsit, Imre

    2007-01-01

    This paper presents a new technique for the analysis of neutron pulse height distributions generated in an organic scintillation detector. The methodology presented in this paper can be applied to techniques such as neutron spectrum unfolding, which have a variety of applications, including nuclear nonproliferation and homeland security. The technique is based on two independent approaches: (i) the use of the MCNP-PoliMi code to simulate neutron detection on an event-by-event basis via the Monte Carlo method and (ii) an analytical approach for neutron slowing down and detection processes. We show that the total neutron pulse height response measured by the organic scintillators is given by the sum of a large number of different neutron histories, each composed of a certain number of neutron scatterings on hydrogen and/or on carbon. The relative contributions of each of these histories are described for a cylindrical liquid scintillator BC-501A. The total simulated pulse height distributions are compared to experimental data measured using two neutron sources, Cf-252 and Am-Be, and very good agreement is achieved. Simulations and measurements of neutron pulse height distributions are essential for neutron spectrum unfolding procedures.

  5. Analysis of Neutron and Photon Detection Position for the Calibration of Plastic (BC-420) and Liquid (BC-501) Scintillators

    SciTech Connect

    Pozzi, S.A.

    2003-08-27

    This report presents the results of the neutron and photon calibration of a Bicron BC-420 plastic scintillator and a BC-501 liquid scintillator using a set of reference gamma sources and a Cf-252 source. The position of neutron and photon detection inside the scintillators as a function of energy is investigated by Monte Carlo simulation.

  6. Structural design of a high energy particle detector using liquid scintillator

    SciTech Connect

    Berg, Timothy John; /Minnesota U.

    1997-02-01

    This thesis presents a design for a 10,000 ton liquid scintillator neutrino detector being considered for the MINOS project at Fermilab. Details of designing, manufacturing, and assembling the active detector components are presented. The detector consists of 1080 magnetized steel absorber planes alternating with 1080 active detector planes. Each active plane is made up of plastic extrusions divided into nearly 400 cells for positional resolution. Life tests on the plastic extrusions determine their feasibility for containing the scintillator. The extrusions are sealed at the bottom, filled with liquid scintillator, and have an optical fiber running the entire length of each cell. The fibers terminate at the top of each extrusion in a manifold. An optical-fiber-light-guide connects the fibers in each manifold to a photo-detector. The photo-detector converts the light signals from the scintillator and optical fibers into electrical impulses for computer analysis.

  7. Characterizing Scitillation and Cherenkov Light Yield in Water-Based Liquid Scintillators

    NASA Astrophysics Data System (ADS)

    Land, B. J.; Caravaca, J.; Descamps, F. B.; Orebi Gann, G. D.

    2016-03-01

    The recent development of Water-based Liquid Scintillator (WbLS) has made it possible to produce scintillating materials with highly tunable light yields and excellent optical clarity. This allows for a straightforward combination of the directional properties of Cherenkov light with the greater energy resolution afforded by the typically brighter scintillation light, which lends itself well to a broad program of neutrino physics. Here we explore the light yields and optical properties of WbLS materials in development for Theia (formerly ASDC) as measured in our benchtop Theia R&D at Berkeley Lab and extrapolate to larger detectors.

  8. A Highly Efficient Neutron Veto Using Boron-Loaded Liquid Scintillator

    SciTech Connect

    Wright, A.; Mosteiro, P.; Loer, B.; Calaprice, F.

    2011-04-27

    By surrounding a dark matter detector with a layer of boron-loaded liquid scintillator, a highly efficient neutron veto can be produced. In Monte Carlo studies, a one meter thick layer of scintillator has a veto efficiency greater than 99.5% for nuclear recoil events induced by radiogenic neutrons, and a veto efficiency of more than 95% for nuclear recoil events produced by cosmogenic neutrons. The use of boron-loaded scintillator both reduces the veto-induced dead time by decreasing the neutron capture time and allows high neutron detection efficiency to be achieved in a relatively compact geometry.

  9. Measurement of actinides in environmental samples by Photo-Electron Rejecting Alpha Liquid Scintillation

    SciTech Connect

    Cadieux, J.R.; Clark, S.; Fjeld, R.A.; Reboul, S.; Sowder, A.

    1994-05-01

    This work describes the adaptation of extractive scintillation with a Photo-Electron Rejecting Alpha Liquid Scintillation (PERALS) (ORDELA, Inc.) spectrometer to the analysis of actinides in environmental samples from the Savannah River Site (SRS). Environmental quality assurance standards and actual water samples were treated by one of two methods; either a two step direct extraction, or for more complex samples, pretreatment by an extraction chromatographic separation prior to measurement of the alpha activity by PERALS.

  10. A study of the scintillation light induced in liquid xenon by electrons and alpha particles

    NASA Technical Reports Server (NTRS)

    Aprile, Elena; Mukherjee, Reshmi; Suzuki, Masayo

    1990-01-01

    The time dependence and the intensity of the primary scintillation light in liquid Xe excited by Am-241 alpha particles and Bi-207 internal-conversion electrons were measured at different electric-field strengths. High-purity liquid Xe was used to fill a parallel-plate ionization chamber equipped with a CaF2 window coupled to a UV-sensitive photomultiplier tube. The effect of the specific ionization density on the scintillation light and the time correlation between the light signal and the charge signal is reported. It is demonstrated that the fast scintillation signal produced in liquid Xe by an ionizing particle provides an ideal trigger in a detector aiming at a complete three-dimensional event reconstruction with an excellent background rejection capability.

  11. Development of a low background liquid scintillation counter for a shallow underground laboratory.

    PubMed

    Erchinger, J L; Aalseth, C E; Bernacki, B E; Douglas, M; Fuller, E S; Keillor, M E; Morley, S M; Mullen, C A; Orrell, J L; Panisko, M E; Warren, G A; Williams, R O; Wright, M E

    2015-11-01

    Pacific Northwest National Laboratory has recently opened a shallow underground laboratory intended for measurement of low-concentration levels of radioactive isotopes in samples collected from the environment. The development of a low-background liquid scintillation counter is currently underway to further augment the measurement capabilities within this underground laboratory. Liquid scintillation counting is especially useful for measuring charged particle (e.g., β and α) emitting isotopes with no (or very weak) gamma-ray yields. The combination of high-efficiency detection of charged particle emission in a liquid scintillation cocktail coupled with the low-background environment of an appropriately designed shield located in a clean underground laboratory provides the opportunity for increased-sensitivity measurements of a range of isotopes. To take advantage of the 35m-water-equivalent overburden of the underground laboratory, a series of simulations have evaluated the scintillation counter's shield design requirements to assess the possible background rate achievable. This report presents the design and background evaluation for a shallow underground, low background liquid scintillation counter design for sample measurements. PMID:26334781

  12. Attempt to determine the environmental 36Cl concentration in water by liquid scintillation counting

    NASA Astrophysics Data System (ADS)

    Florkowski, T.; Schuszler, Ch.

    1986-11-01

    A low-background liquid scintillation spectrometer (ALOKA SL-1) located in the IAEA Isotope Hydrology Laboratory in Vienna was used for 36Cl activity measurement in water samples. The procedure of sample preparation consists of synthesizing of silicon tetrachloride or sodium chloride followed by purification. In both cases the limiting factor in the analysis appeared to be the pure reproducibility of the sample preparation procedure. The conclusion from these experiments is that the liquid scintillation method could be feasible only for the identification of the "bomb chlorine" but is far from being suitable for the accurate determination of 36Cl in groundwater for dating purposes.

  13. Direct measurement of carbon-14 in carbon dioxide by liquid scintillation counting

    NASA Technical Reports Server (NTRS)

    Horrocks, D. L.

    1969-01-01

    Liquid scintillation counting technique is applied to the direct measurement of carbon-14 in carbon dioxide. This method has high counting efficiency and eliminates many of the basic problems encountered with previous techniques. The technique can be used to achieve a percent substitution reaction and is of interest as an analytical technique.

  14. Liquid scintillator for 2D dosimetry for high-energy photon beams

    SciTech Connect

    Poenisch, Falk; Archambault, Louis; Briere, Tina Marie; Sahoo, Narayan; Mohan, Radhe; Beddar, Sam; Gillin, Michael T.

    2009-05-15

    Complex radiation therapy techniques require dosimetric verification of treatment planning and delivery. The authors investigated a liquid scintillator (LS) system for application for real-time high-energy photon beam dosimetry. The system was comprised of a transparent acrylic tank filled with liquid scintillating material, an opaque outer tank, and a CCD camera. A series of images was acquired when the tank with liquid scintillator was irradiated with a 6 MV photon beam, and the light data measured with the CCD camera were filtered to correct for scattering of the optical light inside the liquid scintillator. Depth-dose and lateral profiles as well as two-dimensional (2D) dose distributions were found to agree with results from the treatment planning system. Further, the corrected light output was found to be linear with dose, dose rate independent, and is robust for single or multiple acquisitions. The short time needed for image acquisition and processing could make this system ideal for fast verification of the beam characteristics of the treatment machine. This new detector system shows a potential usefulness of the LS for 2D QA.

  15. Development of a low background liquid scintillation counter for a shallow underground laboratory

    SciTech Connect

    Erchinger, Jennifer L.; Aalseth, Craig E.; Bernacki, Bruce E.; Douglas, Matthew; Fuller, Erin S.; Keillor, Martin E.; Morley, Shannon M.; Mullen, Crystal A.; Orrell, John L.; Panisko, Mark E.; Warren, Glen A.; Williams, Russell O.; Wright, Michael E.

    2015-08-20

    Pacific Northwest National Laboratory has recently opened a shallow underground laboratory intended for measurement of lowconcentration levels of radioactive isotopes in samples collected from the environment. The development of a low-background liquid scintillation counter is currently underway to further augment the measurement capabilities within this underground laboratory. Liquid scintillation counting is especially useful for measuring charged particle (e.g., B, a) emitting isotopes with no (orvery weak) gamma-ray yields. The combination of high-efficiency detection of charged particle emission in a liquid scintillation cocktail coupled with the low-background environment of an appropriately-designed shield located in a clean underground laboratory provides the opportunity for increased-sensitivity measurements of a range of isotopes. To take advantage of the 35-meter water-equivalent overburden of the underground laboratory, a series of simulations have evaluated the instrumental shield design requirements to assess the possible background rate achievable. This report presents the design and background evaluation for a shallow underground, low background liquid scintillation counter design for sample measurements.

  16. Effect of quench on alpha/beta pulse shape discrimination of liquid scintillation cocktails.

    PubMed

    DeVol, Timothy A; Theisen, Christopher D; DiPrete, David P

    2007-05-01

    The objectives of this paper are (1) to illustrate that knowledge of the external quench parameter is insufficient to properly setup a pulse shape discriminating liquid scintillation counter (LSC) for quantitative measurement, (2) to illustrate dependence on pulse shape discrimination on the radionuclide (more than just radiation and energy), and (3) to compare the pulse shape discrimination (PSD) of two commercial instruments. The effects various quenching agents, liquid scintillation cocktails, radionuclides, and LSCs have on alpha/beta pulse shape discriminating liquid scintillation counting were quantified. Alpha emitting radionuclides (239)Pu and (241)Am and beta emitter (90)Sr/(90)Y were investigated to quantify the nuclide dependence on alpha/beta pulse shape discrimination. Also, chemical and color quenching agents, nitromethane, nitric acid, and yellow dye impact on alpha/beta pulse shape discrimination using PerkinElmer Optiphase "HiSafe" 2 and 3, and Ultima Gold AB liquid scintillation cocktails were determined. The prepared samples were counted on the PerkinElmer Wallac WinSpectral 1414 alpha/beta pulse shape discriminating LSC. It was found that for the same level of quench, as measured by the external quench parameter, different quench agents influenced the pulse shape discrimination and the pulse shape discrimination parameters differently. The radionuclide also affects alpha/beta pulse shape discrimination. By comparison with the PerkinElmer Tri-carb 3150 TR/AB, the Wallac 1414 exhibited better pulse shape discrimination capability under the same experimental conditions. PMID:17440321

  17. ACID EVAPORATION OF ULTIMA GOLD TM AB LIQUID SCINTILLATION COCKTAIL RESIDUE

    SciTech Connect

    Kyser, E.; Fondeur, F.; Crump, S.

    2011-12-21

    Prior analyses of samples from the F/H Lab solutions showed the presence of diisopropylnapthalene (DIN), a major component of Ultima Gold{trademark} AB liquid scintillation cocktail (LSC). These solutions are processed through H-Canyon Tank 10.5 and ultimately through the 17.8E evaporator. Similar solutions originated in SRNL streams sent to the same H Canyon tanks. This study examined whether the presence of these organics poses a process-significant hazard for the evaporator. Evaporation and calorimetry testing of surrogate samples containing 2000 ppm of Ultima Gold{trademark} AB LSC in 8 M nitric acid have been completed. These experiments showed that although reactions between nitric acid and the organic components do occur, they do not appear to pose a significant hazard for runaway reactions or generation of energetic compounds in canyon evaporators. The amount of off-gas generated was relatively modest and appeared to be well within the venting capacity of the H-Canyon evaporators. A significant fraction of the organic components likely survives the evaporation process primarily as non-volatile components that are not expected to represent any new process concerns during downstream operations such as neutralization. Laboratory Waste solutions containing minor amounts of DIN can be safely received, stored, transferred, and processed through the canyon waste evaporator.

  18. Liquid scintillation counting methodology for 99Tc analysis. A remedy for radiopharmaceutical waste

    SciTech Connect

    Khan, Mumtaz; Um, Wooyong

    2015-08-13

    This paper presents a new approach for liquid scintillation counting (LSC) analysis of single-radionuclide samples containing appreciable organic or inorganic quench. This work offers better analytical results than existing LSC methods for technetium-99 (99gTc) analysis with significant savings in analysis cost and time. The method was developed to quantify 99gTc in environmental liquid and urine samples using LSC. Method efficiency was measured in the presence of 1.9 to 11,900 ppm total dissolved solids. The quench curve was proved to be effective in the case of spiked 99gTc activity calculation for deionized water, tap water, groundwater, seawater, and urine samples. Counting efficiency was found to be 91.66% for Ultima Gold LLT (ULG-LLT) and Ultima Gold (ULG). Relative error in spiked 99gTc samples was ±3.98% in ULG and ULG-LLT cocktails. Minimum detectable activity was determined to be 25.3 mBq and 22.7 mBq for ULG-LLT and ULG cocktails, respectively. A pre-concentration factor of 1000 was achieved at 100°C for 100% chemical recovery.

  19. Metal-organic scintillator crystals for X-ray, gamma ray, and neutron detection

    SciTech Connect

    Boatner, Lynn A; Kolopus, James A.; Neal, John S; Ramey, Joanne Oxendine; Wisniewski, Dariusz J

    2012-01-03

    New metal-organic materials are useful as scintillators and have the chemical formula LX.sub.3(CH.sub.3OH).sub.4 where L is Y, Sc, or a lanthanide element, and X is a halogen element. An example of the scintillator materials is CeCl.sub.3(CH.sub.3OH).sub.4.

  20. Determination of 226Ra and 224Ra in drinking waters by liquid scintillation counting.

    PubMed

    Manjón, G; Vioque, I; Moreno, H; García-Tenorio, R; García-León, M

    1997-04-01

    A method for the determination of Ra-isotopes in water samples has been developed. Ra is coprecipitated with Ba as sulphate. The precipitate is then dissolved with EDTA and counted with a liquid scintillation system after mixing with a scintillation cocktail. The study of the temporal evolution of the separated activity gives the isotopic composition of the sample, i.e. the 224Ra and 226Ra contribution to the total activity. The method has been applied to some Spanish drinking waters. PMID:9106993

  1. Immobilization of organic liquid wastes

    SciTech Connect

    Greenhalgh, W.O.

    1985-08-07

    This report describes a portland cement immobilization process for the disposal treatment of radioactive organic liquid wastes which would be generated in a a FFTF fuels reprocessing line. An incineration system already on-hand was determined to be too costly to operate for the 100 to 400 gallons per year organic liquid. Organic test liquids were dispersed into an aqueous phosphate liquid using an emulsifier. A total of 109 gallons of potential and radioactive aqueous immiscible organic liquid wastes from Hanford 300 Area operations were solidified with portland cement and disposed of as solid waste during a 3-month test program with in-drum mixers. Waste packing efficiencies varied from 32 to 40% and included pump oils, mineral spirits, and TBP-NPH type solvents.

  2. Searching for dark matter annihilation to monoenergetic neutrinos with liquid scintillation detectors

    SciTech Connect

    Kumar, J.; Sandick, P.

    2015-06-22

    We consider searches for dark matter annihilation to monoenergetic neutrinos in the core of the Sun. We find that liquid scintillation neutrino detectors have enhanced sensitivity to this class of dark matter models, due to the energy and angular resolution possible for electron neutrinos and antineutrinos that scatter via charged-current interactions. In particular we find that KamLAND, utilizing existing data, could provide better sensitivity to such models than any current direct detection experiment for m{sub X}≲15 Gev. KamLAND’s sensitivity is signal-limited, and future liquid scintillation or liquid argon detectors with similar energy and angular resolution, but with larger exposure, will provide significantly better sensitivity. These detectors may be particularly powerful probes of dark matter with mass O(10) GeV.

  3. Low-Afterglow, High-Refractive-Index Liquid Scintillators for Fast-Neutron Spectrometry and Imaging Applications

    NASA Astrophysics Data System (ADS)

    Lauck, Ronald; Brandis, Michal; Bromberger, Benjamin; Dangendorf, Volker; Goldberg, Mark B.; Mor, Ilan; Tittelmeier, Kai; Vartsky, David

    2009-06-01

    For ion and neutron spectrometry and imaging applications at a high intensity pulsed laser facility, fast liquid scintillators with very low afterglow are required. Furthermore, neutron imaging with fiber (or liquid-core) capillary arrays calls for scintillation materials with high refractive index. To this end, we have examined various combinations of established mixtures of fluors and solvents, that were enriched alternatively with nitrogen or oxygen. Dissolved molecular oxygen is known to be a highly effective quenching agent, that efficiently suppresses the population of the triplet states in the fluor, which are primarily responsible for the afterglow. For measuring the glow curves of scintillators, we have employed the time-correlated single photon counting (TCSPC) technique, characterized by high dynamic range of several orders of magnitude in light intensity. In this paper we outline the application for the fast scintillators, briefly present the scintillation mechanism in liquids, describe our specific TCSPC method and discuss the results.

  4. Development and Operation of a Liquid Scintillator Purification System for a Solar Neutrino Detector

    NASA Astrophysics Data System (ADS)

    Chen, M.; Benziger, J. B.; Calaprice, F. P.; Darnton, N.; Johnson, M.; Loeser, F.; Vogelaar, R. B.

    1996-10-01

    An on-line purification system for a large-scale, liquid scintillator detector has been developed for the Counting Test Facility (CTF), a five-ton prototype of the Borexino solar neutrino detector at Gran Sasso. This purification system was operated to remove radioactive impurities from the pseudocumene-based scintillator in the CTF. Counter-current water extraction was performed to remove ionic impurities from the scintillator. Notably, the radon daughters ^210Bi and ^210Po were identified prior to purification and were successfully removed by water extraction. Vacuum distillation of the entire scintillator mixture allowed high radiopurity and chemical purity to be maintained; in addtion, it enabled a test of the origin of ^14C in the scintillator mixture to be performed. Finally, nitrogen stripping was utilized to remove noble gas radioactive isotopes, such as ^85Kr and ^222Rn. The results of the CTF purification activities and an overview of the purification scheme for the Borexino solar neutrino experiment will be presented.

  5. Using the transportable, computer-operated, liquid-scintillator fast-neutron spectrometer system

    SciTech Connect

    Thorngate, J.H.

    1988-11-01

    When a detailed energy spectrum is needed for radiation-protection measurements from approximately 1 MeV up to several tens of MeV, organic-liquid scintillators make good neutron spectrometers. However, such a spectrometer requires a sophisticated electronics system and a computer to reduce the spectrum from the recorded data. Recently, we added a Nuclear Instrument Module (NIM) multichannel analyzer and a lap-top computer to the NIM electronics we have used for several years. The result is a transportable fast-neutron spectrometer system. The computer was programmed to guide the user through setting up the system, calibrating the spectrometer, measuring the spectrum, and reducing the data. Measurements can be made over three energy ranges, 0.6--2 MeV, 1.1--8 MeV, or 1.6--16 MeV, with the spectrum presented in 0.1-MeV increments. Results can be stored on a disk, presented in a table, and shown in graphical form. 5 refs., 51 figs.

  6. Evaluation of the ultrasonic method for solubilizing Daphnia magna before liquid scintillation counting

    SciTech Connect

    Dauble, D.D.; Hanf, R.W. Jr.; Carlile, D.W.

    1984-11-01

    Adult Daphnia magna were exposed to /sup 14/C-labeled phenol and tissues analyzed for /sup 14/C uptake by three methods: (1) tissue solubilizer, (2) tissue solubilizer plus sonication, and (3) sonication alone. Analysis by liquid scintillation counting revealed that measurements of total activity among treatments were not significantly different (..cap alpha.. less than or equal to 0.10) at two count levels. Sonicated samples showed less variation than tissue samples that were solubilized. 5 references, 1 table.

  7. The 90 ton liquid scintillation detector in the Mont Blanc Laboratory

    NASA Astrophysics Data System (ADS)

    Badino, G.; Bologna, G.; Castagnoli, C.; Fulgione, W.; Galeotti, P.; Saavedra, O.; Dadykin, V. L.; Korchagin, V. B.; Korchagin, P. V.; Malgin, A. S.

    1984-12-01

    The authors discuss the results from calibrating liquid scintillation counters (1.5 m3 each) used in the large-volume neutrino experiment in the Mont Blanc Laboratory. The electronic and recording systems from the 72 counters of the detector are described, and the method to detect low-energy γ pulses from (n,p) reaction by using 252Cf as a neutron source is discussed.

  8. The research program of the Liquid Scintillation Detector (LSD) in the Mont Blanc Laboratory

    NASA Technical Reports Server (NTRS)

    Dadykin, V. L.; Yakushev, V. F.; Korchagin, P. V.; Korchagin, V. B.; Malgin, A. S.; Ryassny, F. G.; Ryazhskaya, O. G.; Talochkin, V. P.; Zatsepin, G. T.; Badino, G.

    1985-01-01

    A massive (90 tons) liquid scintillation detector (LSD) has been running since October 1984 in the Mont Blanc Laboratory at a depth of 5,200 hg/sq cm of standard rock. The research program of the experiment covers a variety of topics in particle physics and astrophysics. The performance of the detector, the main fields of research are presented and the preliminary results are discussed.

  9. Solar neutrino interactions with liquid scintillators used for double beta-decay experiments

    NASA Astrophysics Data System (ADS)

    Ejiri, Hiroyasu; Zuber, Kai

    2016-08-01

    Solar neutrinos interact within double-beta-decay (DBD) detectors and hence will contribute to backgrounds (BGs) for DBD experiments. Background contributions due to solar neutrinos are evaluated for their interactions with atomic electrons and nuclei in liquid scintillation detectors used for DBD experiments. They are shown to be serious BGs for high-sensitivity DBD experiments to search for the Majorana neutrino masses in the inverted and normal hierarchy regions.

  10. Development of an Ultra-Low Background Liquid Scintillation Counter for Trace Level Analysis

    SciTech Connect

    Erchinger, Jennifer L.; Orrell, John L.; Aalseth, Craig E.; Bernacki, Bruce E.; Douglas, Matthew; Finn, Erin C.; Fuller, Erin S.; Keillor, Martin E.; Morley, Shannon M.; Mullen, Crystal A.; Panisko, Mark E.; Shaff, Sarah M.; Warren, Glen A.; Wright, Michael E.

    2015-09-01

    Low-level liquid scintillation counting (LSC) has been established as one of the radiation detection techniques useful in elucidating environmental processes and environmental monitoring around nuclear facilities. The Ultra-Low Background Liquid Scintillation Counter (ULB-LSC) under construction in the Shallow Underground Laboratory at Pacific Northwest National Laboratory aims to further reduce the MDAs and/or required sample processing. Through layers of passive shielding in conjunction with an active veto and 30 meters water equivalent overburden, the background reduction is expected to be 10 to 100 times below typical analytic low-background liquid scintillation systems. Simulations have shown an expected background of around 14 counts per day. A novel approach to the light collection will use a coated hollow light guide cut into the inner copper shielding. Demonstration LSC measurements will show low-energy detection, spectral deconvolution, and alpha/beta discrimination capabilities, from trials with standards of tritium, strontium-90, and actinium-227, respectively. An overview of the system design and expected demonstration measurements will emphasize the potential applications of the ULB-LSC in environmental monitoring for treaty verification, reach-back sample analysis, and facility inspections.

  11. ZICOS - New project for neutrinoless double beta decay experiment using zirconium complex in liquid scintillator

    NASA Astrophysics Data System (ADS)

    Fukuda, Yoshiyuki

    2016-05-01

    A liquid scintillator containing a tetrakis (isopropyl acetoacetato) zirconium has been developed for new project of neutrinoless double beta decay experiment (ZICOS experiment). We have synthesized a tetrakis (isopropyl acetoacetato) zirconium, which have high solubility (over 31.2 wt.%) in anisole. We measured the performance of liquid scintillator containing 10 wt.% concentration of a tetrakis (isopropyl acetoacetato) zirconium, and obtained 48.7 ± 7.1% of the light yield of BC505 and the energy resolution of 4.1 ± 0.6% at 3.35 MeV assuming 40% photo coverage of the photomultiplier, respectively. We also estimated that ZICOS experiment should be sensitive to (mν) < 0.1 eV assuming gA = 1.25, gpp = 1.11 and QRPA model, if a radius of the inner detector is 1.5 m and the detector is filled with this liquid scintillator with an enriched 96Zr nucleus and we can reduce 208 Tl backgrounds to be one tenth order of magnitude of KamLAND-Zen using Cherenkov lights.

  12. Design of a Low Background Liquid Scintillation Counter for a Shallow Underground Laboratory

    NASA Astrophysics Data System (ADS)

    Orrell, John; Aalseth, Craig; Bernacki, Bruce; Douglas, Matt; Erchinger, Jennifer; Fuller, Erin; Keillor, Martin; Morley, Shannon; Mullen, Crystal; Panisko, Mark; Shaff, Sarah; Warren, Glen; Wright, Michael

    2014-09-01

    Pacific Northwest National Laboratory operates a 35-meter water-equivalent overburden, shallow underground laboratory for measuring low-concentration radioactive isotopes in environmental samples collected. A low-background liquid scintillation counter is under development. Liquid scintillation counting is useful for beta-emitting isotopes without (or low) gamma ray yields. The high-efficiency beta detection in a liquid scintillation cocktail coupled with the low-background environment of a shield located in a clean underground laboratory provides for increased-sensitivity measurements to a range of isotopes. Benchmarked simulations have evaluated the shield design requirements to assess the background rate achievable. Assay of shield construction materials provides the basis for the shield design development. The low background design is informed by efforts in experimental design of neutrinoless double beta decay experiments, direct detection dark matter experiments, and low energy neutrino detection experiments. In this vein a background budget for the instrument is presented with attention to low background methods directed toward applications of nuclear measurements.

  13. Neutron emission measurement at the HL-2A tokamak device with a liquid scintillation detector

    SciTech Connect

    Xie, Xufei; Chen, Zhongjing; Peng, Xingyu; Yuan, Xi; Zhang, Xing; Cui, Zhiqiang; Du, Tengfei; Hu, Zhimeng; Li, Tao; Fan, Tieshuan Chen, Jinxiang; Li, Xiangqing; Zhang, Guohui; Gorini, Giuseppe; Yuan, Guoliang; Yang, Jinwei; Yang, Qingwei

    2014-10-15

    Neutron emission measurement at the HL-2A tokamak device with a liquid scintillation detector is described. The detector was placed at a location with little structure material in the field of view, and equipped with a gain monitoring system which could provide the possibility to evaluate the gain variation as well as to correct for the detector response. Time trace of the neutron emissivity was obtained and it was consistent with the result of a standard {sup 235}U fission chamber. During the plasma discharge the neutron yield could vary by about four orders of magnitude and the fluctuation of the detector gain was up to about 6%. Pulse height spectrum of the liquid scintillation detector was constructed and corrected with the aid of the gain monitoring system, and the correction was found to be essential for the assessment of the neutron energy spectrum. This successful measurement offered experience and confidence for the application of liquid scintillation detectors in the upcoming neutron camera system.

  14. Simple algorithms for digital pulse-shape discrimination with liquid scintillation detectors

    NASA Astrophysics Data System (ADS)

    Alharbi, T.

    2015-01-01

    The development of compact, battery-powered digital liquid scintillation neutron detection systems for field applications requires digital pulse processing (DPP) algorithms with minimum computational overhead. To meet this demand, two DPP algorithms for the discrimination of neutron and γ-rays with liquid scintillation detectors were developed and examined by using a NE213 liquid scintillation detector in a mixed radiation field. The first algorithm is based on the relation between the amplitude of a current pulse at the output of a photomultiplier tube and the amount of charge contained in the pulse. A figure-of-merit (FOM) value of 0.98 with 450 keVee (electron equivalent energy) energy threshold was achieved with this method when pulses were sampled at 250 MSample/s and with 8-bit resolution. Compared to the similar method of charge-comparison this method requires only a single integration window, thereby reducing the amount of computations by approximately 40%. The second approach is a digital version of the trailing-edge constant-fraction discrimination method. A FOM value of 0.84 with an energy threshold of 450 keVee was achieved with this method. In comparison with the similar method of rise-time discrimination this method requires a single time pick-off, thereby reducing the amount of computations by approximately 50%. The algorithms described in this work are useful for developing portable detection systems for applications such as homeland security, radiation dosimetry and environmental monitoring.

  15. Probing the Earth’s interior with a large-volume liquid scintillator detector

    NASA Astrophysics Data System (ADS)

    Hochmuth, Kathrin A.; Feilitzsch, Franz V.; Fields, Brian D.; Undagoitia, Teresa Marrodán; Oberauer, Lothar; Potzel, Walter; Raffelt, Georg G.; Wurm, Michael

    2007-02-01

    A future large-volume liquid scintillator detector would provide a high-statistics measurement of terrestrial antineutrinos originating from β-decays of the uranium and thorium chains. In addition, the forward displacement of the neutron in the detection reaction ν+p→n+e provides directional information. We investigate the requirements on such detectors to distinguish between certain geophysical models on the basis of the angular dependence of the geoneutrino flux. Our analysis is based on a Monte-Carlo simulation with different levels of light yield, considering both unloaded and gadolinium-loaded scintillators. We find that a 50 kt detector such as the proposed LENA (Low Energy Neutrino Astronomy) will detect deviations from isotropy of the geoneutrino flux significantly. However, with an unloaded scintillator the time needed for a useful discrimination between different geophysical models is too large if one uses the directional information alone. A Gd-loaded scintillator improves the situation considerably, although a 50 kt detector would still need several decades to distinguish between a geophysical reference model and one with a large neutrino source in the Earth’s core. However, a high-statistics measurement of the total geoneutrino flux and its spectrum still provides an extremely useful glance at the Earth’s interior.

  16. Recent Developments In Fast Neutron Detection And Multiplicity Counting With Verification With Liquid Scintillator

    SciTech Connect

    Nakae, L; Chapline, G; Glenn, A; Kerr, P; Kim, K; Ouedraogo, S; Prasad, M; Sheets, S; Snyderman, N; Verbeke, J; Wurtz, R

    2011-09-30

    For many years at LLNL, we have been developing time-correlated neutron detection techniques and algorithms for applications such as Arms Control, Threat Detection and Nuclear Material Assay. Many of our techniques have been developed specifically for the relatively low efficiency (a few percent) attainable by detector systems limited to man-portability. Historically, we used thermal neutron detectors (mainly {sup 3}He), taking advantage of the high thermal neutron interaction cross-sections. More recently, we have been investigating the use of fast neutron detection with liquid scintillators, inorganic crystals, and in the near future, pulse-shape discriminating plastics which respond over 1000 times faster (nanoseconds versus tens of microseconds) than thermal neutron detectors. Fast neutron detection offers considerable advantages, since the inherent nanosecond production time-scales of spontaneous fission and neutron-induced fission are preserved and measured instead of being lost by thermalization required for thermal neutron detectors. We are now applying fast neutron technology to the safeguards regime in the form of fast portable digital electronics as well as faster and less hazardous scintillator formulations. Faster detector response times and sensitivity to neutron momentum show promise for measuring, differentiating, and assaying samples that have modest to very high count rates, as well as mixed fission sources like Cm and Pu. We report on measured results with our existing liquid scintillator array, and progress on the design of a nuclear material assay system that incorporates fast neutron detection, including the surprising result that fast liquid scintillator detectors become competitive and even surpass the precision of {sup 3}He-based counters measuring correlated pairs in modest (kg) samples of plutonium.

  17. Recent Developments in Fast Neutron Detection and Multiplicity Counting with Liquid Scintillator

    NASA Astrophysics Data System (ADS)

    Nakae, L. F.; Chapline, G. F.; Glenn, A. M.; Kerr, P. L.; Kim, K. S.; Ouedraogo, S. A.; Prasad, M. K.; Sheets, S. A.; Snyderman, N. J.; Verbeke, J. M.; Wurtz, R. E.

    2011-12-01

    For many years, LLNL researchers have been developing time-correlated neutron detection techniques and algorithms for applications such as Arms Control, Threat Detection and Nuclear Material Assay. Many of the techniques have been developed specifically for the relatively low efficiency (a few percent) attainable by detector systems limited to man-portability. Historically, thermal neutron detectors (mainly 3He) were used, taking advantage of the high thermal neutron interaction cross sections. More recently, we have been investigating the use of fast neutron detection with liquid scintillators, inorganic crystals, and in the near future, pulse-shape discriminating plastics that respond over 1000 times faster (ns versus tens of μs) than thermal neutron detectors. Fast neutron detection offers considerable advantages since the inherent ns production timescales of spontaneous fission and neutron-induced fission are preserved and measured instead of being lost by thermalization required for thermal neutron detectors. We are now applying fast neutron technology to the safeguards regime in the form of fast portable digital electronics as well as faster and less hazardous scintillator formulations. Faster detector response times and sensitivity to neutron momentum show promise for measuring, differentiating, and assaying samples that have modest to very high count rates, as well as mixed fission sources like Cm and Pu. We report on measured results with our existing liquid scintillator array and progress on the design of a nuclear material assay system that incorporates fast neutron detection, including the surprising result that fast liquid scintillator detectors become competitive and even surpass the precision of 3He-based counters measuring correlated pairs in modest (kg) samples of plutonium.

  18. Recent Developments in Neutron Detection and Multiplicity Counting with Liquid Scintillator

    SciTech Connect

    Nakae, L F; Kerr, P L; Newby, R J; Prasad, M K; Rowland, M S; Snyderman, N J; Verbeke, J M; Wurtz, R E

    2010-01-07

    For many years at LLNL we have been developing time-correlated neutron detection techniques and algorithms for many applications including Arms Control, Threat Detection and Nuclear Material Assaying. Many of our techniques have been developed specifically for relatively low efficiency (a few %) inherent in the man-portable systems. Historically we used thermal neutron detectors (mainly {sup 3}He) taking advantage of the high thermal neutron interaction cross-sections but more recently we have been investigating fast neutron detection with liquid scintillators and inorganic crystals. We have discovered considerable detection advantages with fast neutron detection as the inherent nano-second production time-scales of fission and neutron induced fission are preserved instead of being lost in neutron thermalization required for thermal neutron detectors. We are now applying fast neutron technology (new fast and portable digital electronics as well as new faster and less hazardous scintillator formulations) to the safeguards regime and faster detector response times and neutron momentum sensitivity show promise in measuring, differentiating and assaying samples that have very high count rates as well as mixed fission sources (e.g. Cm and Pu). We report on measured results with our existing liquid scintillator array and progress on design of nuclear material assaying system that incorporates fast neutron detection.

  19. Evidence of delayed light emission of tetraphenyl-butadiene excited by liquid-argon scintillation light

    NASA Astrophysics Data System (ADS)

    Segreto, E.

    2015-03-01

    Tetraphenyl-butadiene is the wavelength shifter most widely used in combination with liquid argon. The latter emits scintillation photons with a wavelength of 127 nm that need to be downshifted to be detected by photomultipliers with glass or quartz windows. Tetraphenyl-butadiene has been demonstrated to have an extremely high conversion efficiency, possibly higher than 100% for 127 nm photons, while there is no precise information about the time dependence of its emission. It is usually assumed to be exponentially decaying with a characteristic time of the order of one ns, as an extrapolation from measurements with exciting radiation in the near UV. This work shows that tetraphenyl-butadiene, when excited by 127 nm photons, re-emits photons not only with a very short decay time, but also with slower ones due to triplet states de-excitations. This fact can strongly contribute to clarifying the anomalies in liquid-argon scintillation light reported in the literature since the 1970s, namely, the inconsistency in the measured values of the long decay time constant and the appearance of an intermediate component. Similar effects should be also expected when the TPB is used in combination with helium and neon, which emit scintillation photons with wavelengths shorter than 127 nm.

  20. Preliminary study of light yield dependence on LAB liquid scintillator composition

    NASA Astrophysics Data System (ADS)

    Ye, Xing-Chen; Yu, Bo-Xiang; Zhou, Xiang; Zhao, Li; Ding, Ya-Yun; Liu, Meng-Chao; Ding, Xue-Feng; Zhang, Xuan; Jie, Quan-Lin; Zhou, Li; Fang, Jian; Chen, Hai-Tao; Hu, Wei; Niu, Shun-Li; Yan, Jia-Qing; Zhao, Hang; Hong, Dao-Jin

    2015-09-01

    Liquid scintillator (LS) will be adopted as the detector material in JUNO (Jiangmen Underground Neutrino Observatory). The energy resolution requirement of JUNO is 3%, which has never previously been reached. To achieve this energy resolution, the light yield of liquid scintillator is an important factor. PPO (the fluor) and bis-MSB (the wavelength shifter) are the two main materials dissolved in LAB. To study the influence of these two materials on the transmission of scintillation photons in LS, 25 and 12 cm-long quartz vessels were used in a light yield experiment. LS samples with different concentration of PPO and bis-MSB were tested. At these lengths, the light yield growth is not obvious when the concentration of PPO is higher than 4 g/L. The influence from bis-MSB becomes insignificant when its concentration is higher than 8 mg/L. This result could provide some useful suggestions for the JUNO LS. Supported by Strategic Priority Research Program of Chinese Academy of Sciences (XDA10010500), National Natural Science Foundation of China (11390384) and CAS Center for Excellence in Particle Physics (CCEPP)

  1. Coil spring conveyor for positioning an external radioactive standard in a liquid scintillation counter

    SciTech Connect

    Kampf, R.S.

    1986-03-04

    This patent describes a liquid scintillation counter having a counting chamber for receiving a liquid sample containing a liquid scintillator and a sample of a radioactive substance to be counted. An improved apparatus is described for positioning a radioactive source in an operating location to irradiate the liquid sample in the counting chamber comprising the combination of: (1) a flexible conveyor including an elongate, generally tubular coil spring section having an interior tubular bore configured to receive the radioactive source; (2) means for retaining the radioactive source in a predetermined axial position within the coil spring; (3) means supporting the coil spring for movement along a conveyor path between a storage location for the radioactive source remote from the counting chamber and an operating location for the radioactive source proximate the counting chamber; and (4) drive means coupled to the coil spring and operative to drive the coil spring along the conveyor path for conveying the radioactive source between the storage and operating locations.

  2. A large-scale low-background liquid scintillation detector: the counting test facility at Gran Sasso

    NASA Astrophysics Data System (ADS)

    Alimonti, G.; Arpesella, C.; Bacchiocchi, G.; Balata, M.; Bellini, G.; Benziger, J.; Bonetti, S.; Brigatti, A.; Cadonati, L.; Calaprice, F. P.; Cavaletti, R.; Cecchet, G.; Chen, M.; Darnton, N.; Debari, A.; Deutsch, M.; Elisei, F.; von Feilitzsch, F.; Galbiati, C.; Garagiola, A.; Gatti, F.; Giammarchi, M. G.; Giugni, D.; Goldbrunner, T.; Golubchikov, A.; Goretti, A.; Grabar, S.; Hagner, T.; Hartmann, F.; von Hentig, R.; Heusser, G.; Ianni, A.; Jochum, J.; Johnson, M.; Laubenstein, M.; Loeser, F.; Lombardi, P.; Magni, S.; Malvezzi, S.; Manno, I.; Manuzio, G.; Masetti, F.; Mazzucato, U.; Meroni, E.; Neff, M.; Nisi, S.; Nostro, A.; Oberauer, L.; Perotti, A.; Preda, A.; Raghavan, P.; Raghavan, R. S.; Ranucci, G.; Resconi, E.; Ruscitti, P.; Scardaoni, R.; Schoenert, S.; Smirnov, O.; Tartaglia, R.; Testera, G.; Ullucci, P.; Vogelaar, R. B.; Vitale, S.; Zaimidoroga, O.

    1998-02-01

    A 4.8 m3 unsegmented liquid scintillation detector at the underground Laboratori Nazionali del Gran Sasso has shown the feasibility of multi-ton low-background detectors operating to energies as low as 250 keV. Detector construction and the handling of large volumes of liquid scintillator to minimize the background are described. The scintillator, 1.5 g PPO/L-pseudocumene, is held in a flexible nylon vessel shielded by 1000 t of purified water. The active detector volume is viewed by 100 photomultipliers, which measure time and charge for each event, from which energy, position and pulse shape are deduced. On-line purification of the scintillator by water extraction, vacuum distillation and nitrogen stripping removed radioactive impurities. Upper limits were established of < 10-7 Bq/kg-scintillator for events with energies 250 keV < E < 800 keV, and < 10-9 Bq/kg-scintillator due to the decay products of uranium and thorium. The isotopic abundance of 14C/12C in the scintillator was shown to be approximately 10-18 by extending the energy window of the detector to 25-250 keV. The 14C abundance and uranium and thorium levels in the CTF are compatible with the Borexino Solar Neutrino Experiment.

  3. Scintillation photon detection in liquid argon at the Long-Baseline Neutrino Facility

    NASA Astrophysics Data System (ADS)

    Howard, Bruce; Adams, Brice; Baugh, Brian; Buchanan, Norm; Bugel, Len; Conrad, Janet; Davis, Ronald; Gebhard, Mark; Lang, Michael; Miner, Bill; Mufson, Stuart; Musser, James; Pordes, Stephen; Rebel, Brian; Smith, Paul; Toups, Matt; Urheim, Jon; Warner, David; Wongjirad, Taritree; Whittington, Denver

    2015-04-01

    The proposed Long-Baseline Neutrino Facility (LBNF) aims to answer outstanding questions relating to neutrino physics and other phenomena, such as proton decay and supernova neutrinos. The proposed far detector design calls for a multi-kiloton liquid argon time-projection chamber at a long baseline. In addition to its utility as a target material, liquid argon scintillates in the far UV, providing further physics information and serving as a trigger for non-beam events. The photon detection system in development for the LBNF far detector includes a mechanism for capturing and transporting the light, a method to detect the photons (silicon photomultipliers), and the necessary readout electronics. Testing in liquid argon has occurred at the ``TallBo'' facility at Fermilab to characterize and compare the performance of these systems. In this talk, we present the details of these photon detection systems and the latest results of testing.

  4. Development of deep-UV sensitive MPPC for liquid xenon scintillation detector

    NASA Astrophysics Data System (ADS)

    Ootani, W.; Ieki, K.; Iwamoto, T.; Kaneko, D.; Mori, T.; Nakaura, S.; Nishimura, M.; Ogawa, S.; Sawada, R.; Shibata, N.; Uchiyama, Y.; Yoshida, K.; Sato, K.; Yamada, R.

    2015-07-01

    The liquid xenon (LXe) γ-ray detector for the MEG II experiment is based on a highly granular scintillation readout with Multi-Pixel Photon Counters (MPPCs). Here we report on the development of a large-area MPPC sensitive to LXe scintillation light in deep-UV range for the MEG II LXe detector. A prototype model of the deep-UV MPPC with an active area of 12 × 12mm2 was successfully tested in LXe, showing an excellent performance such as a high photon detection efficiency for the LXe scintillation light (about 20% at ΔV = 2.5 V), a high internal gain (about 106 at ΔV = 2.5 V) and an excellent single photoelectron resolution. The sensor chip of the MPPC is segmented into four sectors, which are then connected in series in order to reduce the overall sensor capacitance. The signal fall time of about 135 ns for the non-segmented sensor was significantly reduced down to 25 ns with the series-connected sensor segments. The preliminary results on the performance of the deep-UV MPPC are presented.

  5. Prompt directional detection of galactic supernova by combining large liquid scintillator neutrino detectors

    NASA Astrophysics Data System (ADS)

    Fischer, V.; Chirac, T.; Lasserre, T.; Volpe, C.; Cribier, M.; Durero, M.; Gaffiot, J.; Houdy, T.; Letourneau, A.; Mention, G.; Pequignot, M.; Sibille, V.; Vivier, M.

    2015-08-01

    Core-collapse supernovae produce an intense burst of electron antineutrinos in the few-tens-of-MeV range. Several Large Liquid Scintillator-based Detectors (LLSD) are currently operated worldwide, being very effective for low energy antineutrino detection through the Inverse Beta Decay (IBD) process. In this article, we develop a procedure for the prompt extraction of the supernova location by revisiting the details of IBD kinematics over the broad energy range of supernova neutrinos. Combining all current scintillator-based detector, we show that one can locate a canonical supernova at 10 kpc with an accuracy of 45 degrees (68% C.L.). After the addition of the next generation of scintillator-based detectors, the accuracy could reach 12 degrees (68% C.L.), therefore reaching the performances of the large water Čerenkov neutrino detectors. We also discuss a possible improvement of the SuperNova Early Warning System (SNEWS) inter-experiment network with the implementation of a directionality information in each experiment. Finally, we discuss the possibility to constrain the neutrino energy spectrum as well as the mass of the newly born neutron star with the LLSD data.

  6. Expected performance of an ideal liquid argon neutrino detector with enhanced sensitivity to scintillation light

    NASA Astrophysics Data System (ADS)

    Sorel, M.

    2014-10-01

    Scintillation light is used in liquid argon (LAr) neutrino detectors to provide a trigger signal, veto information against cosmic rays, and absolute event timing. In this work, we discuss additional opportunities offered by detectors with enhanced sensitivity to scintillation light, that is with light collection efficiencies of about 10-3. We focus on two key detector performance indicators for neutrino oscillation physics: calorimetric neutrino energy reconstruction and neutrino/antineutrino separation in a non-magnetized detector. Our results are based on detailed simulations, with neutrino interactions modelled according to the GENIE event generator, while the charge and light responses of a large LAr ideal detector are described by the Geant4 and NEST simulation tools. A neutrino energy resolution as good as 3.3% RMS for 4 GeV electron neutrino charged-current interactions can in principle be obtained in a large detector of this type, by using both charge and light information. By exploiting muon capture in argon and scintillation light information to veto muon decay electrons, we also obtain muon neutrino identification efficiencies of about 50%, and muon antineutrino misidentification rates at the few percent level, for few-GeV neutrino interactions that are fully contained. We argue that the construction of large LAr detectors with sufficiently high light collection efficiencies is in principle possible.

  7. The determination of low levels of cobalt-60 in environmental waters by liquid scintillation counting

    USGS Publications Warehouse

    Claassen, H.C.

    1970-01-01

    A method for determination of cobalt-60 in waters at levels greater than 0.5 pCi per sample is presented. A modification of the method may be used to analyze fluvial sediments and soils. After the cobalt has been separated, first as the hydroxide and then as the thiocyanate complex in methyl isobutyl ketone, it is counted in a liquid scintillation system at 80% efficiency. Separation factors achieved for six isotopes are generally greater than 2,000. The time for a single analysis, exclusive of the counting and evaporation operations, is about 2 h. ?? 1970.

  8. A rope-net support system for the liquid scintillator detector for the SNO+ experiment

    NASA Astrophysics Data System (ADS)

    Bialek, A.; Chen, M.; Cleveland, B.; Gorel, P.; Hallin, A.; Harvey, P. J.; Heise, J.; Kraus, C.; Krauss, C. B.; Lawson, I.; Ng, C. J.; Pinkney, B.; Rogowsky, D. M.; Sibley, L.; Soluk, R.; Soukup, J.; Vázquez-Jáuregui, E.

    2016-08-01

    The detector for the SNO+ experiment consists of 780 000 kg of liquid scintillator contained in an acrylic vessel that is surrounded by water. A mechanical system has been installed to counteract the 1.25 MN of buoyant force on the acrylic and prevent the vessel from moving. The system is a rope net, designed using a Finite Element Analysis to calculate the amount of stress on the acrylic induced by the ropes, hydrostatic pressures and gravity. A dedicated test was performed to measure strains in the acrylic arising from the complex geometry of the knots in the rope system. The ratio between measured and FEA calculated strains was 1.3.

  9. Measurement of liquid scintillation sources of (210)Pb obtained from (222)Rn decay.

    PubMed

    Antohe, A; Sahagia, M; Luca, A; Ioan, M-R; Ivan, C

    2016-03-01

    Liquid scintillation samples were filled with (222)Rn and the activity was measured with good precision after reaching the secular equilibrium with the progeny (218)Po, (214)Pb, (214)Bi and (214)Po. After decay of most of (222)Rn activity, the samples contain (210)Pb and progeny. The activities of (210)Pb and progeny can be calculated as a function of time using the initial (222)Rn activity. The samples were measured in a TDCR counter and the experimentally determined counting efficiencies are in accordance with previously published results. PMID:26725538

  10. Measurements of serum glucose using the luciferin/Luciferase system and a liquid scintillation spectrometer

    SciTech Connect

    Idahl, L.A.; Sandstroem, P.E.; Sehlin, J.

    1986-05-15

    A single-step assay for serum glucose measurements is described. The assay is based on the phosphorylation of D-glucose by glucokinase and the measurement of ATP consumption by firefly luciferase. The luminescence is recorded in an ordinary liquid scintillation spectrometer. The use of stable reagents and a stable final signal (light emission) makes it possible to analyze a large number of samples in each assay run. The assay is of particular value when repeated serum glucose determinations are performed on samples from small laboratory animals.

  11. Neutron detection in a high gamma ray background with liquid scintillators

    SciTech Connect

    Stevanato, L.; Cester, D.; Viesti, G.; Nebbia, G.

    2013-04-19

    The capability of liquid scintillator (namely 2'' Multiplication-Sign 2'' cells of EJ301 and EJ309) of detecting neutrons in a very high gamma ray background is explored. A weak {sup 252}Cf source has been detected in a high {sup 137}Cs gamma ray background corresponding to a dose rate of 100 {mu}Sv/h with probability of detection in compliance with IEC requirements for hand held instruments. Tests were performed with new generation of CAEN digitizers, in particular the V1720 (8 Channel 12bit 250 MS/s) one.

  12. TDCR and CIEMAT/NIST Liquid Scintillation Methods applied to the Radionuclide Metrology

    NASA Astrophysics Data System (ADS)

    da Cruz, P. A. L.; da Silva, C. J.; Iwahara, A.; Loureiro, J. S.; De Oliveira, A. E.; Tauhata, L.; Lopes, R. T.

    2016-07-01

    This work presents TDCR and CIEMAT/NIST methods of liquid scintillation implemented in National Institutes of Metrology for activity standardization of radionuclides, which decay by beta emission and electron capture. The computer codes used to calculate the detection efficiency take into account: decay schemes, beta decay theory, quenching parameter evaluation, Poisson statistic model and Monte Carlo simulation for photon and particle interactions in the detection system. Measurements were performed for pure emitters 3H, 14C, 99Tc and for 68Ge/68Ga which decay by electron capture and positron emission, with uncertainties smaller than 1% (k = 1).

  13. Comparison of (14)C liquid scintillation counting at NIST and NRC Canada.

    PubMed

    Bergeron, Denis E; Galea, Raphael; Laureano-Pérez, Lizbeth; Zimmerman, Brian E

    2016-03-01

    An informal bilateral comparison of (14)C liquid scintillation (LS) counting at the National Research Council of Canada (NRC) and the National Institute of Standards and Technology (NIST) has been completed. Two solutions, one containing (14)C-labeled sodium benzoate and one containing (14)C-labeled n-hexadecane, were measured at both laboratories. Despite observed LS cocktail instabilities, the two laboratories achieved accord in their standardizations of both solutions. At the conclusion of the comparison, the beta spectrum used for efficiency calculations was identified as inadequate and the data were reanalyzed with different inputs, improving accord. PMID:26585641

  14. Hybrid metal organic scintillator materials system and particle detector

    DOEpatents

    Bauer, Christina A.; Allendorf, Mark D.; Doty, F. Patrick; Simmons, Blake A.

    2011-07-26

    We describe the preparation and characterization of two zinc hybrid luminescent structures based on the flexible and emissive linker molecule, trans-(4-R,4'-R') stilbene, where R and R' are mono- or poly-coordinating groups, which retain their luminescence within these solid materials. For example, reaction of trans-4,4'-stilbenedicarboxylic acid and zinc nitrate in the solvent dimethylformamide (DMF) yielded a dense 2-D network featuring zinc in both octahedral and tetrahedral coordination environments connected by trans-stilbene links. Similar reaction in diethylformamide (DEF) at higher temperatures resulted in a porous, 3-D framework structure consisting of two interpenetrating cubic lattices, each featuring basic to zinc carboxylate vertices joined by trans-stilbene, analogous to the isoreticular MOF (IRMOF) series. We demonstrate that the optical properties of both embodiments correlate directly with the local ligand environments observed in the crystal structures. We further demonstrate that these materials produce high luminescent response to proton radiation and high radiation tolerance relative to prior scintillators. These features can be used to create sophisticated scintillating detection sensors.

  15. Organic reactivity in liquid ammonia.

    PubMed

    Ji, Pengju; Atherton, John; Page, Michael I

    2012-08-14

    Liquid ammonia is a useful solvent for many organic reactions including aliphatic and aromatic nucleophilic substitution and metal-ion catalysed reactions. The acidity of acids is modified in liquid ammonia giving rise to differences from conventional solvents. The ionisation constants of phenols and carbon acids are the product of those for ion-pair formation and dissociation to the free ions. There is a linear relationship between the pK(a) of phenols and carbon acids in liquid ammonia and those in water of slope 1.68 and 0.7, respectively. Aminium ions exist in their unprotonated free base form in liquid ammonia. The rates of solvolysis and aminolysis by neutral amines of substituted benzyl chlorides in liquid ammonia show little or no dependence upon ring substituents, in stark contrast with the hydrolysis rates of substituted benzyl halides in water which vary 10(7) fold. However, the rates of the reaction of phenoxide ions and amine anions with 4-substituted benzyl chlorides gives a Hammett ρ = 1.1 and 0.93, respectively. The second order rate constants for the substitution of benzyl chlorides by neutral and anionic amines show a single Brønsted β(nuc) = 0.21 whereas those for substituted phenoxide ions generate a Brønsted β(nuc) = 0.40. The rates of aromatic nucleophilic substitution reactions in liquid ammonia are much faster than those in protic solvents indicating that liquid ammonia behaves like a typical dipolar aprotic solvent in its solvent effects on organic reactions. Nitrofluorobenzenes (NFB) readily undergo solvolysis in liquid ammonia but oxygen nucleophiles, such as alkoxide and phenoxide ions, displace the fluorine of 4-NFB in liquid ammonia to give the corresponding substitution product with little or no competing solvolysis product. The Brønsted β(nuc) for the reaction of 4-NFB with para-substituted phenoxides is 0.91, indicative that the decomposition of the Meisenheimer σ-intermediate is rate limiting. The aminolysis of 4-NFB occurs

  16. Measurement of the muon-induced neutron yield in liquid scintillator and stainless steel at LNGS with the LVD experiment

    SciTech Connect

    Persiani, R.; Garbini, M.; Sartorelli, G.; Selvi, M.; Collaboration: LVD Collaboration

    2013-08-08

    We describe the measurement of the muon-induced neutron yield in liquid scintillator and stainless steel (SS) at the Gran Sasso National Laboratory (LNGS), with the LVD experiment. The Large Volume Detector (LVD) is located in Hall A of the LNGS and is made of 1000 t of liquid scintillator and 1000 t of SS. Using an independent measurement to evaluate the background and with the support of a full Monte Carlo simulation based on Geant4, we measured a neutron yield of (2.9±0.6)×10{sup −4} and (1.5±0.3)×10{sup −3} in liquid scintillator and in stainless steel, respectively.

  17. A neutron multiplicity analysis method for uranium samples with liquid scintillators

    NASA Astrophysics Data System (ADS)

    Zhou, Hao; Lin, Hongtao; Liu, Guorong; Li, Jinghuai; Liang, Qinglei; Zhao, Yonggang

    2015-10-01

    A new neutron multiplicity analysis method for uranium samples with liquid scintillators is introduced. An active well-type fast neutron multiplicity counter has been built, which consists of four BC501A liquid scintillators, a n/γdiscrimination module MPD-4, a multi-stop time to digital convertor MCS6A, and two Am-Li sources. A mathematical model is built to symbolize the detection processes of fission neutrons. Based on this model, equations in the form of R=F*P*Q*T could be achieved, where F indicates the induced fission rate by interrogation sources, P indicates the transfer matrix determined by multiplication process, Q indicates the transfer matrix determined by detection efficiency, T indicates the transfer matrix determined by signal recording process and crosstalk in the counter. Unknown parameters about the item are determined by the solutions of the equations. A 252Cf source and some low enriched uranium items have been measured. The feasibility of the method is proven by its application to the data analysis of the experiments.

  18. Production and optical properties of Gd-loaded liquid scintillator for the RENO neutrino detector

    NASA Astrophysics Data System (ADS)

    Park, J. S.; Lee, J.; Yeo, I. S.; Choi, W. Q.; Ahn, J. K.; Choi, J. H.; Choi, S.; Choi, Y.; Jang, H. I.; Jang, J. S.; Jeon, E. J.; Joo, K. K.; Kim, B. R.; Kim, H. S.; Kim, J. Y.; Kim, S. B.; Kim, S. Y.; Kim, W.; Kim, Y. D.; Lee, J. H.; Lee, J. K.; Lim, I. T.; Ma, K. J.; Pac, M. Y.; Park, I. G.; Park, K. S.; Siyeon, K.; So, S. H.; Stepanyan, S. S.; Yu, I.

    2013-04-01

    Reactor experiment for neutrino oscillation (RENO) began data-taking from August 2011. It successfully observed reactor antineutrino disappearance in April 2012 to measure the smallest mixing angle of θ13. Two identical detectors, one at near location and the other at far location, are constructed at the Yonggwang nuclear power plant in South Korea, to compare the observed reactor neutrino fluxes. Each RENO detector is filled with 16 mass tons of Gadolinium loaded liquid scintillator (GdLS) in the neutrino target region, and with 28 mass tons of unloaded liquid scintillator (LS) in the γ-catcher region surrounding the target. LS was developed to satisfy chemical, physical, optical properties, and safety requirements. Linear alkyl benzene (LAB) was chosen as a solvent because of its high flash-point, sufficient light yield, and being environmentally friendly. GdLS is carefully developed to keep a long attenuation length and high light yield for a long time period. In this paper, we report the characteristics and mass production of the RENO LS and GdLS.

  19. Some applications of Photon/Electron-Rejecting Alpha Liquid Scintillation (PERALS) spectrometry to the assay of alpha emitters

    SciTech Connect

    McDowell, W.J.; Case, G.N.

    1988-01-01

    The combination of certain solvent extraction separations and a special kind of liquid scintillation detector and electronics designed for alpha spectrometry allows some highly accurate, yet simple determinations of alpha-emitting nuclides. Counting efficiency is 99.68% with backgrounds of <0.02 cpm. Energy resolution and peak position are sufficient for the identification of many nuclides. Rejection of interference from ..beta.. and ..gamma.. radiation is >99.95%. The Photon/Electron Rejecting Alpha Liquid Scintillation (PERALS) equipment is described and procedures for the separation and determination of uranium, thorium, plutonium, polonium, radium, and trivalent actinides are outlined. 25 refs., 10 figs., 1 tab.

  20. Laboratory Studies of Lead Removal from Liquid Scintillator in Preparation for KamLAND's Low Background Phase

    SciTech Connect

    Keefer, Gregory

    2011-04-27

    The removal of Radon induced Lead from liquid scintillator was extensively studied in preparation for KamLAND's low background phase. This work presents the results from laboratory experiments performed at the University of Alabama and their implications for KamLAND and future low background experiments using carbon based liquid scintillator. It was observed that distillation was the most effective purification procedure and that one must consider a non-polar and non-ionic component of Lead in order to reach the levels of radio-purity required for these new class of ultra-low background experiments.

  1. X-ray imaging with scintillator-sensitized hybrid organic photodetectors

    NASA Astrophysics Data System (ADS)

    Büchele, Patric; Richter, Moses; Tedde, Sandro F.; Matt, Gebhard J.; Ankah, Genesis N.; Fischer, Rene; Biele, Markus; Metzger, Wilhelm; Lilliu, Samuele; Bikondoa, Oier; MacDonald, J. Emyr; Brabec, Christoph J.; Kraus, Tobias; Lemmer, Uli; Schmidt, Oliver

    2015-12-01

    Medical X-ray imaging requires cost-effective and high-resolution flat-panel detectors for the energy range between 20 and 120 keV. Solution-processed photodetectors provide the opportunity to fabricate detectors with a large active area at low cost. Here, we present a disruptive approach that improves the resolution of such detectors by incorporating terbium-doped gadolinium oxysulfide scintillator particles into an organic photodetector matrix. The X-ray induced light emission from the scintillators is absorbed within hundreds of nanometres, which is negligible compared with the pixel size. Hence, optical crosstalk, a limiting factor in the resolution of scintillator-based X-ray detectors, is minimized. The concept is validated with a 256 × 256 pixel detector with a resolution of 4.75 lp mm-1 at a MTF = 0.2, significantly better than previous stacked scintillator-based flat-panel detectors. We achieved a resolution that proves the feasibility of solution-based detectors in medical applications. Time-resolved electrical characterization showed enhanced charge carrier mobility with increased scintillator filling, which is explained by morphological changes.

  2. The Rayleigh ratio measurement for SNO+ liquid scintillator and background studies of the internal ropes

    NASA Astrophysics Data System (ADS)

    Asahi, Satoko

    As a successor of the Sudbury Neutrino Observatory, the SNO+ experiment is planned to start data taking in early 2013. Making use of the liquid scintillator, Linear Alkylbenzene (LAB), the SNO+ experiment aims to perform flux measurements of low energy solar neutrinos in one phase, and wait for neutrinoless double beta decay events in another phase where 44 kg of natural Neodymium would be added into LAB. The Rayleigh ratio of LAB was found to be 16.60 +/- 3.14 x 10--6 cm--1 at 546 nm using the relative measurement technique. The wavelength dependency of the Rayleigh scattering was also examined and compared with the theoretical prediction. A setup which is usable to measure the angular dependency of the Rayleigh scattering was built, and an isotropic behaviour of the scattering was tested. The beta and gamma backgrounds, due to the internal calibration ropes situated in the scintillator volume, were studied using the SNO+ Monte Carlo Package. Also, the amount of 210Pb originating from the internal calibration ropes due to the intrinsic contamination of 238U, Rn emanation and plated on the surface prior to the installation were assessed to examine if it is a tolerable level to achieve the target level of 13.4 background events per day.

  3. Pulse-shape discrimination and energy resolution of a liquid-argon scintillator with xenon doping

    NASA Astrophysics Data System (ADS)

    Wahl, C. G.; Bernard, E. P.; Lippincott, W. H.; Nikkel, J. A.; Shin, Y.; McKinsey, D. N.

    2014-06-01

    Liquid-argon scintillation detectors are used in fundamental physics experiments and are being considered for security applications. Previous studies have suggested that the addition of small amounts of xenon dopant improves performance in light or signal yield, energy resolution, and particle discrimination. In this study, we investigate the detector response for xenon dopant concentrations from 9 ± 5 ppm to 1100 ± 500 ppm xenon (by weight) in 6 steps. The 3.14-liter detector uses tetraphenyl butadiene (TPB) wavelength shifter with dual photomultiplier tubes and is operated in single-phase mode. Gamma-ray-interaction signal yield of 4.0 ± 0.1 photoelectrons/keV improved to 5.0 ± 0.1 photoelectrons/keV with dopant. Energy resolution at 662 keV improved from (4.4 ± 0.2)% (σ) to (3.5 ± 0.2)% (σ) with dopant. Pulse-shape discrimination performance degraded greatly at the first addition of dopant, slightly improved with additional additions, then rapidly improved near the end of our dopant range, with performance becoming slightly better than pure argon at the highest tested dopant concentration. Some evidence of reduced neutron scintillation efficiency with increasing dopant concentration was observed. Finally, the waveform shape outside the TPB region is discussed, suggesting that the contribution to the waveform from xenon-produced light is primarily in the last portion of the slow component.

  4. Characterization of a liquid scintillator based on linear alkyl benzene for neutron detection

    NASA Astrophysics Data System (ADS)

    Bentoumi, G.; Dai, X.; Fritzsche, H.; Jonkmans, G.; Li, L.; Marleau, G.; Sur, B.

    2013-02-01

    A liquid scintillator (LS) based on linear alkyl benzene (LAB) solvent has been characterized using multiple radiation sources. The results confirm that boron-loaded LAB is suitable for neutron detection in a gamma ray environment. To study indirectly the LAB pulse shape discrimination (PSD) capability between neutrons and gamma rays, a dissolved 212Pb source emitting alpha and beta particles was used to emulate the conditions in a mixed radiation field for detecting neutrons in the presence of a high gamma ray background. The quenching factor depends on the alpha energy and increases from 10 to 25 as the alpha energy decreases from 10 to 1 MeV. 10B loaded LAB-based LS has been tested in a neutron beam of energy which is equal to 14.56 meV. The observed peak at 60 keVee is attributed to the absorption of neutrons. Our results show that a boron-loaded LAB-based scintillator is a sensitive medium for neutron detection in a relatively large background of gamma rays. A neutron detector could be achieved with a figure of merit (FOM) of 1.75.

  5. Apparatus for positioning an external radioactive standard in a liquid scintillation counter

    SciTech Connect

    Horrocks, D.L.; Kampf, R.S.

    1987-07-07

    This patent describes a liquid scintillation counter having a counting chamber for receiving a sample containing a scintillator substance and a sample of a radioactive substance to be counted. The improved apparatus positions a radioactive source in an operating location to irradiate the sample in the counting chamber comprising, in combination: (1) a continuous bidirectionally flexible conveyor forming a closed loop for conveying the radioactive source through on operating location and a storage location; (2) means supporting the radioactive source at a position along the flexible conveyor for conveyance; (3) guide means for supporting the conveyor and for guiding conveyor movement along a selected path, the path transversing at spaced positions the storage location for the radioactive source remote from the counting chamber and the operating location for the radioactive source near to the counting chamber; and (4) drive means coupled to the continuous flexible conveyor to draw the conveyor around the path for conveying the radioactive source through the spaced storage and operating locations.

  6. Online calibration of neutrino liquid scintillator detectors above 10 MeV

    NASA Astrophysics Data System (ADS)

    Chepurnov, A. S.; Gromov, M. B.; Shamarin, A. F.

    2016-02-01

    Online calibration of neutrino liquid scintillator detector at energies above 10 MeV is very important for study of such rare process as supernova and for correct calculation of backgrounds if spectral properties is the focus of researches. The traditional procedure implies the usage of radioactive sources with well-known spectral properties but such approach is limited by available radioactive sources, upper possible energies (∼10-11 MeV) and dangerous for ultra low background environment of modern detectors. The approach we propose is based on simulation of events with controllable UV double LED pulser. The LED's main wavelength fits the scintillator excitation wavelength. This technique allows to simulate physical events within the detector in very wide energy range from a few hundred keV to about 50 MeV. Additional studies like pile-up analysis can be performed due to double-LEDs scheme which generates two delayed signals with different adjustable amplitudes. The delay time is also adjustable parameter.

  7. Preparation of Gd Loaded Liquid Scintillator for Daya Bay Neutrino Experiment

    SciTech Connect

    Ding Yayun; Zhang Zhiyong

    2010-05-12

    Gadolinium loaded liquid scintillator (Gd-LS) is an excellent target material for reactor antineutrino experiments. Ideal Gd-LS should have long attenuation length, high light yield, long term stability, low toxicity, and should be compatible with the material used to build the detector. We have developed a new Gd-LS recipe in which carboxylic acid 3,5,5-trimethylhexanoic acid is used as the complexing ligand to gadolinium, 2,5-diphenyloxazole (PPO) and 1,4-bis[2-methylstyryl]benzene (bis-MSB) are used as primary fluor and wavelength shifter, respectively. The scintillator base is linear alkyl benzene (LAB). Eight hundred liters of Gd-LS has been synthesized and tested in a prototype detector. Results show that the Gd-LS has high quality and is suitable for underground experiments in large quantity. Large scale production facility has been built. A full batch production of 4 t Gd-LS has been produced and monitored for several months. The production of 180 t Gd-LS will be carried out in the near future.

  8. Simulating response functions and pulse shape discrimination for organic scintillation detectors with Geant4

    NASA Astrophysics Data System (ADS)

    Hartwig, Zachary S.; Gumplinger, Peter

    2014-02-01

    We present new capabilities of the Geant4 toolkit that enable the precision simulation of organic scintillation detectors within a comprehensive Monte Carlo code for the first time. As of version 10.0-beta, the Geant4 toolkit models the data-driven photon production from any user-defined scintillator, photon transportation through arbitrarily complex detector geometries, and time-resolved photon detection at the light readout device. By fully specifying the optical properties and geometrical configuration of the detector, the user can simulate response functions, photon transit times, and pulse shape discrimination. These capabilities enable detector simulation within a larger experimental environment as well as computationally evaluating novel scintillators, detector geometry, and light readout configurations. We demonstrate agreement of Geant4 with the NRESP7 code and with experiments for the spectroscopy of neutrons and gammas in the ranges 0-20 MeV and 0.511-1.274 MeV, respectively, using EJ301-based organic scintillation detectors. We also show agreement between Geant4 and experimental modeling of the particle-dependent detector pulses that enable simulated pulse shape discrimination.

  9. An alpha–gamma coincidence spectrometer based on the Photon–Electron Rejecting Alpha Liquid Scintillation (PERALS®) system

    DOE PAGESBeta

    Cadieux, J. R.; Fugate, G. A.; King, III, G. S.

    2015-02-07

    Here, an alpha–gamma coincidence spectrometer has been developed for the measurement of selected actinide isotopes in the presence of high beta/gamma fields. The system is based on a PERALS® liquid scintillation counter for beta/alpha discrimination and was successfully tested with both high purity germanium and bismuth germanate, gamma-ray detectors using conventional analog electronics.

  10. Liquid scintillation counting of polycarbonates: a sensitive technique for measurement of activity concentration of some radioactive noble gases.

    PubMed

    Mitev, K; Zhivkova, V; Pressyanov, D; Georgiev, S; Dimitrova, I; Gerganov, G; Boshkova, T

    2014-11-01

    This work explores the application of the liquid scintillation counting of polycarbonates for measurement of the activity concentration of radioactive noble gases. Results from experimental studies of the method are presented. Potential applications in the monitoring of radioactive noble gases are discussed. PMID:24559941

  11. Analysis of 161Tb by radiochemical separation and liquid scintillation counting

    DOE PAGESBeta

    Jiang, J.; Davies, A.; Arrigo, L.; Friese, J.; Seiner, B. N.; Greenwood, L.; Finch, Z.

    2015-12-05

    The determination of 161Tb activity is problematic due to its very low fission yield, short half-life, and the complication of its gamma spectrum. At AWE, radiochemically purified 161Tb solution was measured on a PerkinElmer 1220 QuantulusTM Liquid Scintillation Spectrometer. Since there was no 161Tb certified standard solution available commercially, the counting efficiency was determined by the CIEMAT/NIST Efficiency Tracing method. The method was validated during a recent inter-laboratory comparison exercise involving the analysis of a uranium sample irradiated with thermal neutrons. Lastly, the measured 161Tb result was in excellent agreement with the result using gamma spectrometry and the result obtainedmore » by Pacific Northwest National Laboratory.« less

  12. PROSPECT Background Studies and Operation of Li-Loaded Liquid Scintillator Detectors at a Research Reactor

    NASA Astrophysics Data System (ADS)

    Langford, Thomas; Prospect Collaboration

    2015-04-01

    Segmented antineutrino detectors placed near compact research reactors provide an excellent opportunity to probe short-baseline neutrino oscillations and precisely measure the reactor antineutrino spectrum. PROSPECT is a phased experiment that will explore the favored reactor anomaly parameter space at the High Flux Isotope Reactor (HFIR) at Oak Ridge National Lab. Measurements of the reactor correlated and ambient backgrounds will be presented, as well as a discussion of active and passive mitigation plans. A lithium-loaded liquid scintillator test detector is currently in operation at HFIR within a prototype shielding cave. Results from recent operation will be presented along with a discussion of their impact on PROSPECT. on behalf of the PROSPECT collaboration.

  13. Determination of 36Cl in biological shield concrete using pyrohydrolysis and liquid scintillation counting.

    PubMed

    Itoh, Mitsuo; Watanabe, Kazuo; Hatakeyama, Mutsuo; Tachibana, Mitsuo

    2002-07-01

    A method for the determination of 36Cl in biological shield concrete of nuclear reactors was developed. Cl in the concrete sample was extracted quantitatively by pyrohydrolysis at 900 degrees C and recovered in Na2CO3 solution for subsequent measurement of 36Cl by liquid scintillation counting. WO3 was used as an accelerator in the pyrohydrolysis. The Cl extraction procedure was optimized by investigating experimental conditions with the use of ion chromatography and its recovery was evaluated by the analysis of the geochemical reference samples. The detection limit of 36Cl was 0.02 Bq g(-1) for a sample weight of 2 g. The relative standard deviation was 3-7% for the samples containing 0.5 Bq g(-1) levels of 36Cl. The method was applied to determine 36Cl in biological shield concrete of the Japan Power Demonstration Reactor. PMID:12173658

  14. Optimization of liquid scintillation measurements applied to smears and aqueous samples collected in industrial environments

    NASA Astrophysics Data System (ADS)

    Chapon, Arnaud; Pigrée, Gilbert; Putmans, Valérie; Rogel, Gwendal

    Search for low-energy β contaminations in industrial environments requires using Liquid Scintillation Counting. This indirect measurement method supposes a fine control from sampling to measurement itself. Thus, in this paper, we focus on the definition of a measurement method, as generic as possible, for both smears and aqueous samples' characterization. That includes choice of consumables, sampling methods, optimization of counting parameters and definition of energy windows, using the maximization of a Figure of Merit. Detection limits are then calculated considering these optimized parameters. For this purpose, we used PerkinElmer Tri-Carb counters. Nevertheless, except those relative to some parameters specific to PerkinElmer, most of the results presented here can be extended to other counters.

  15. Suppression of gamma-ray sensitivity of liquid scintillators for neutron detection

    NASA Astrophysics Data System (ADS)

    Swiderski, L.; Moszyński, M.; Wolski, D.; Iwanowska, J.; Szczęśniak, T.; Schotanus, P.; Hurlbut, C.

    2011-10-01

    Methods to reduce gamma-ray sensitivity of a liquid scintillator EJ309 have been studied. Zero-crossing pulse shape discrimination method was used to separate events generated by neutron and gamma radiation between 60- keVee and 4 MeVee. The measurements were carried out under irradiation from an intense 137Cs source, yielding dose rate of 10 mR/h at the detector. A Pu-Be source was used to establish neutron integration window. Pile-up rejection (PUR) circuit was used to reduce gamma-ray induced events under irradiation from an intense gamma-ray source. Further, application of lead, tin and copper shields was done in order to decrease intrinsic gamma-neutron detection efficiency.

  16. Analysis of 161Tb by radiochemical separation and liquid scintillation counting

    SciTech Connect

    Jiang, J.; Davies, A.; Arrigo, L.; Friese, J.; Seiner, B. N.; Greenwood, L.; Finch, Z.

    2015-12-05

    The determination of 161Tb activity is problematic due to its very low fission yield, short half-life, and the complication of its gamma spectrum. At AWE, radiochemically purified 161Tb solution was measured on a PerkinElmer 1220 QuantulusTM Liquid Scintillation Spectrometer. Since there was no 161Tb certified standard solution available commercially, the counting efficiency was determined by the CIEMAT/NIST Efficiency Tracing method. The method was validated during a recent inter-laboratory comparison exercise involving the analysis of a uranium sample irradiated with thermal neutrons. Lastly, the measured 161Tb result was in excellent agreement with the result using gamma spectrometry and the result obtained by Pacific Northwest National Laboratory.

  17. Measurements of Separate Neutron and Gamma-Ray Coincidences with Liquid Scintillators and Digital PSD Technique

    SciTech Connect

    Flaska, Marek; Pozzi, Sara A

    2007-10-01

    A new technique is presented for the measurement of neutron and/or gamma-ray coincidences. Separate neutron neutron, neutron gamma-ray, gamma-ray neutron, and gamma-ray gamma-ray coincidences are acquired with liquid scintillation detectors and a digital pulse shape discrimination (PSD) technique based on standard charge integration method. The measurement technique allows for the collection of fast coincidences in a time window of the order of a few tens of nanoseconds between the coincident particles. The PSD allows for the acquisition of the coincidences in all particle combinations. The measurements are compared to results obtained with the MCNP-PoliMi code, which simulates neutron and gamma-ray coincidences from from a source on an event-by-event basis. This comparison leads to good qualitative agreement.

  18. Validation of efficiency tracing and zero detection threshold techniques using liquid scintillation analyser TriCarb.

    PubMed

    Reddy, P J; Bhade, S P D; Babu, D A R; Sharma, D N

    2011-11-01

    Efficiency tracing with unquenched 14C and zero detection threshold with unquenched 3H as tracers are practical and simple techniques which have been implemented to quantify the activity of various beta emitters using liquid scintillation analyser. These techniques are used to study the influence of quench level on activity quantification and the activity levels up to which these techniques are applicable. The results indicate that, for an activity level of 166.67 Bq, both the techniques are in good agreement with the reference activity with a relative discrepancy of ≤4.6 %. The relative discrepancy of ~10 % is observed for extreme quench values of ~111. For all the radionuclides with the activity level of 1.67 Bq, the uncertainty in activity quantification raises to ~8 % and for the activity level from 8.33 to 100 Bq, the uncertainty reduces to 1 %. PMID:21196460

  19. Characterization of liquid scintillation detector (BC-501A) and digital pulse shape discrimination (DPSD) system

    SciTech Connect

    Lombigit, L. Yussup, N. Ibrahim, Maslina Mohd; Rahman, Nur Aira Abd; Rawi, M. Z. M.

    2015-04-29

    A digital n/γ pulse shape discrimination (PSD) system is currently under development at Instrumentation and Automation Centre, Malaysian Nuclear Agency. This system aims at simultaneous detection of fast neutron and gamma ray in mixed radiations environment. This work reports the system characterization performed on the liquid scintillation detector (BC-501A) and digital pulse shape discrimination (DPSD) system. The characterization involves measurement of electron light output from the BC-501A detector and energy channels calibration of the pulse height spectra acquired with DPSD system using set of photon reference sources. The main goal of this experiment is to calibrate the ADC channel of our DPSD system, characterized the BC-501 detector and find the position of Compton edge which later could be used as threshold for the n/γ PSD experiment. The detector resolution however is worse as compared to other published data but it is expected as our detector has a smaller active volume.

  20. Fast-neutron imaging spectrometer based on liquid scintillator loaded capillaries

    NASA Astrophysics Data System (ADS)

    Mor, I.; Vartsky, D.; Brandis, M.; Goldberg, M. B.; Bar, D.; Mardor, I.; Dangendorf, V.; Bromberger, B.

    2012-04-01

    A fast-neutron imaging detector based on micrometric glass capillaries loaded with high refractive index liquid scintillator has been developed Neutron energy spectrometry is based on event-by-event detection and reconstruction of neutron energy from the measurement of the knock-on proton track length and the amount of light produced in the track. In addition, the detector can provide fast-neutron imaging with position resolution of tens of microns. The detector principle of operation, simulations and experimental results obtained with a small detector prototype are described. We have demonstrated by simulation energy spectrum reconstruction for incident neutrons in the range of 4-20 MeV. The energy resolution in this energy range was 10-15%. Preliminary experimental results of detector spectroscopic capabilities are presented

  1. Characterization of a 10B-doped liquid scintillator as a capture-gated neutron spectrometer

    NASA Astrophysics Data System (ADS)

    Hunt, S.; Iliadis, C.; Longland, R.

    2016-03-01

    We use a 250 MHz digitizer to characterize the pulse shape discrimination of a BC-523A 10B-doped liquid scintillator with capture-gating capabilities. Our results are compared to recent work claiming pulse shape discrimination between fast and thermal neutron signals. The capture event is identified, and we explain the origin of signals that are often misinterpreted. We use the time-of-flight method to measure the detector energy resolution for fast incident monoenergetic neutrons and the intrinsic neutron detection efficiency. Monte Carlo simulations are performed and we find agreement between measured and simulated results. These steps are important for understanding 10B-doped capture-gated spectroscopy in mixed radiation environments, as efficiencies using capture-gating are rarely reported in the literature.

  2. Procedure for separation of Se and determination of Se-79 by liquid scintillation

    SciTech Connect

    Dewberry, R.A.

    1991-08-11

    This report describes the development work and demonstration of a technique for separation of selenium suitable for determination of Se-79 by liquid scintillation counting. The technique has been demonstrated on actual DWPF (Defense Waste Processing Facility) sludge samples which contain very large loads of Sr-90 activity. The separation required a decontamination of selenium from Sr by a factor of over 10{sup 6}, from Co and Cs by factor of 10{sup 4}, and from Tc-99 by a factor of 100, while still maintaining a selenium recovery of about 50%. Using this technique the author has determined Se-79 in five actual DWPF samples with a precision of about 70% relative standard deviation. This separation has not been demonstrated on actual DWPF samples which have the largest Cs-137 loads. He does not anticipate that these untested samples will present a difficult problem.

  3. Determination of (226)Ra in produced water by liquid scintillation counting.

    PubMed

    Godoy, José Marcus; Vianna, Lucas M; Godoy, Maria Luiza D P; Almeida, Ana Cristina

    2016-08-01

    It is proposed a method for the determination of (226)Ra in offshore platform liquid effluent samples (produced water). The method is based on a two-phase liquid scintillation counting system and allows for the direct and simple determination of (226)Ra content. Samples with high barium content may also have high (226)Ra concentration. Therefore, the sample volume is based on the barium concentration and ranges from 10 mL to 100 mL. Our new method was tested using multiple real samples and was compared with the BaSO4 precipitation method. The results based on the LSC were 30% higher than the precipitation method, which is attributed to the self-absorption of alpha particles in the BaSO4 precipitate. The determination of both (226)Ra and (228)Ra in the liquid effluent of offshore oil platforms is mandatory in Brazil. Thus, a second method of accurately assessing (228)Ra content remains necessary. PMID:27116402

  4. Exploration of the potential of liquid scintillators for real-time 3D dosimetry of intensity modulated proton beams

    PubMed Central

    Beddar, Sam; Archambault, Louis; Sahoo, Narayan; Poenisch, Falk; Chen, George T.; Gillin, Michael T.; Mohan, Radhe

    2009-01-01

    In this study, the authors investigated the feasibility of using a 3D liquid scintillator (LS) detector system for the verification and characterization of proton beams in real time for intensity and energy-modulated proton therapy. A plastic tank filled with liquid scintillator was irradiated with pristine proton Bragg peaks. Scintillation light produced during the irradiation was measured with a CCD camera. Acquisition rates of 20 and 10 frames per second (fps) were used to image consecutive frame sequences. These measurements were then compared to ion chamber measurements and Monte Carlo simulations. The light distribution measured from the images acquired at rates of 20 and 10 fps have standard deviations of 1.1% and 0.7%, respectively, in the plateau region of the Bragg curve. Differences were seen between the raw LS signal and the ion chamber due to the quenching effects of the LS and due to the optical properties of the imaging system. The authors showed that this effect can be accounted for and corrected by Monte Carlo simulations. The liquid scintillator detector system has a good potential for performing fast proton beam verification and characterization. PMID:19544791

  5. REMOVAL OF URANIUM FROM ORGANIC LIQUIDS

    DOEpatents

    Vavalides, S.P.

    1959-08-25

    A process is described for recovering small quantities of uranium from organic liquids such as hydrocarbon oils. halogen-substituted hydrocarbons, and alcohols. The organic liquid is contacted with a comminuted alkaline earth hydroxide, calcium hydroxide particularly, and the resulting uranium-bearing solid is separated from the liquid by filtration. Uranium may then be recovered from the solid by means of dissolution in nitric acid and conventional extraction with an organic solvent such as tributyl phosphate.

  6. Characterizing a fast-response, low-afterglow liquid scintillator for neutron time-of-flight diagnostics in fast ignition experiments

    SciTech Connect

    Abe, Y. Hosoda, H.; Arikawa, Y.; Nagai, T.; Kojima, S.; Sakata, S.; Inoue, H.; Iwasa, Y.; Iwano, K.; Yamanoi, K.; Fujioka, S.; Nakai, M.; Sarukura, N.; Shiraga, H.; Norimatsu, T.; Azechi, H.

    2014-11-15

    The characteristics of oxygen-enriched liquid scintillators with very low afterglow are investigated and optimized for application to a single-hit neutron spectrometer for fast ignition experiments. It is found that 1,2,4-trimethylbenzene has better characteristics as a liquid scintillator solvent than the conventional solvent, p-xylene. In addition, a benzophenon-doped BBQ liquid scintillator is shown to demonstrate very rapid time response, and therefore has potential for further use in neutron diagnostics with fast time resolution.

  7. Automated high performance liquid chromatography and liquid scintillation counting determination of pesticide mixture octanol/water partition rates

    SciTech Connect

    Moody, R.P.; Carroll, J.M.; Kresta, A.M.

    1987-12-01

    Two novel methods are reported for measuring octanol/water partition rates of pesticides. A liquid scintillation counting (LSC) method was developed for automated monitoring of /sup 14/C-labeled pesticides partitioning in biphasic water/octanol cocktail systems with limited success. A high performance liquid chromatography (HPLC) method was developed for automated partition rate monitoring of several constituents in a pesticide mixture, simultaneously. The mean log Kow +/- SD determined from triplicate experimental runs were for: 2,4-D-DMA (2,4-dichlorophenoxyacetic acid dimethylamine), 0.65 +/- .17; Deet (N,N-diethyl-m-toluamide), 2.02 +/- .01; Guthion (O,O-dimethyl-S-(4-oxo-1,2,3-benzotriazin-3(4H)-ylmethyl) phosphorodithioate), 2.43 +/- .03; Methyl-Parathion (O,O-dimethyl-O-(p-nitrophenyl) phosphorothioate), 2.68 +/- .05; and Fenitrothion (O,O-dimethyl O-(4-nitro-m-tolyl) phosphorothioate), 3.16 +/- .03. A strong positive linear correlation (r = .9979) was obtained between log Kow and log k' (log Kow = 2.35 (log k') + 0.63). The advantages that this automated procedure has in comparison with the standard manual shake-flask procedure are discussed.

  8. Relative scintillation efficiency of liquid xenon in the XENON10 direct dark matter search

    NASA Astrophysics Data System (ADS)

    Manzur, Angel

    There is almost universal agreement that most of the mass in the Universe consists of dark matter. Many lines of reasoning suggest that the dark matter consists of a weakly interactive massive particle (WIMP) with mass ranging from 10 GeV/c 2 to a few TeV/c 2 . Today, numerous experiments aim for direct or indirect dark matter detection. XENON10 is a direct detection experiment using a xenon dual phase time projection chamber. Particles interacting with xenon will create a scintillation signal ( S 1) and ionization. The charge produced is extracted into the gas phase and converted into a proportional scintillation light ( S 2), with an external electric field. The dominant background, b particles and g rays, will undergo an electron recoil (ER) interaction, while WIMPs and neutrons will undergo a nuclear recoil (NR) interaction. Event-by-event discrimination of background signals is based on log 10 ( S 2/ S 1) NR < log 10 ( S 2/ S 1) ER and the 3-D position reconstruction. In 2006 the XENON10 detector started underground operations at laboratorio Nazionali del Gran Sasso in Italy. After 6 months of operations, totaling 58.6 live days and 5.4 kg of fiducial mass, XENON10 set the best upper limits at the time. Finding a spin- independent WIMP-nucleon cross-section s h = 8.8 × 10^-44 cm 2 and a spin- dependent WIMP-neutron cross-section s h = 1.0 × 10^-38 cm 2 for a WIMP mass of 100 GeV/c 2 (90% C.L.). In this work I give an overview of the dark matter evidence and review the requirements for a dark matter search. In particular I discuss the XENON10 detector, deployment, operation, calibrations, analysis and WIMP-nucleon cross- section limits. Finally, I present our latest results for the relative scintillation efficiency ([Special characters omitted.] ) for nuclear recoils in liquid xenon, which was the biggest source of uncertainty in the XENON10 limit. This quantity is essential to determine the nuclear energy scale and to determine the WIMP-nucleon cross

  9. SOLVENT PURIFICATION AND FLUOR SELECTION FOR GADOLINIUM-LOADED LIQUID SCINTILLATORS

    SciTech Connect

    Kesete, T.; Storm, A.; Hahn, R. L.; Yeh, M.; Seleem, S.

    2007-01-01

    The last decade has seen huge progress in the study of neutrinos, elementary sub-atomic particles. Continued growth in the fi eld of neutrino research depends strongly on the calculation of the neutrino mixing angle θ13, a fundamental neutrino parameter that is needed as an indicative guideline for proposed next-generation neutrino experiments. Experiments involving reactor antineutrinos are favored for the calculation of θ13 because their derivation equation for θ13 is relatively simple and unambiguous. A Gd-loaded liquid scintillator (Gd-LS) is the centerpiece of the detector and it consists of ~99% aromatic solvent, ~0.1% Gd, and < 1% fl uors. Key required characteristics of the Gd-LS are long-term chemical stability, high optical transparency, and high photon production by the scintillator. This summer’s research focused on two important aspects of the detector: (1) purifi cation of two selected scintillation solvents, 1, 2, 4-trimethylbenzene (PC) and linear alkyl benzene (LAB), to improve the optical transparency and long-term chemical stability of the Gd-LS, and (2) investigation of the added fl uors to optimize the photon production. Vacuum distillation and column separation were used to purify PC and LAB, respectively. Purifi cation was monitored using UV-visible absorption spectra and verifi ed in terms of decreased solvent absorption at 430nm. Absorption in PC at 430nm decreased by a factor slightly >10 while the absorption in LAB was lowered by a factor of ~5. Photon production for every possible combination of two solvents, four primary shifters, and two secondary shifters was determined by measuring the Compton-Scattering excitation induced by an external Cs-137 gamma source (Eγ ~ 662-keV). The ideal shifter concentration was identifi ed by measuring the photon production as a function of shifter quantity in a series of samples. Results indicate that 6g/L p-terphenyl with 150mg/L 1,4-Bis(2-methylstyryl)-benzene (bis-MSB) produces the maximum

  10. Landau Energy Loss in Liquid Scintillator and the Search for Wifs with the LVD Experiment.

    NASA Astrophysics Data System (ADS)

    Tang, Jie

    The LVD experiment at Gran Sasso, Italy, is described, and data since the completion of the first tower (one fifth of the whole LVD) are analyzed. The dE/dx distribution of reconstructed high-energy muons in the scintillator counters is obtained. This distribution is compared with predictions by a GEANT3 Monte Carlo simulation of cosmic muons going through the LVD detector. Its shape is similar to the Landau approximation. In the data from a total running time of 245 days, 159286 clearly separable charged tracks going through the detector were reconstructed. No WIF (Weakly-Interacting Fractionally-charged particle) is observed. Since the early 1930's to the 1980's, theories on the dE/dx distribution of charged particles in matter have evolved from the fundamental work done by Bethe, Bloch, Landau, Symon, Vavilov and others with the inclusion of more precise corrections of the density effect and the shell effect. At the LVD experiment, through a procedure of gain-factor calibration at every period of 20 days, to compensate for instability and nonuniformity of the scintillator counters and their readout, the muon dE/dx distribution is measured; it conforms to the Landau approximation. The precision of the dE/dx measurement is 7.6% (one sigma).. WIF particles are speculated by modern theories. Because dE/dx is proportional to the square of the charge carried by the incident particle, any WIF going through the LVD liquid scintillator will reveal itself by its dE/dx being on the low side of the carefully calibrated muon dE/dx distribution. Calculation has shown that when the charge of a WIF is as low as {2over 3} e, it still generates enough ionization in the LVD limited streamer tubes and thus its track is as visible as a muon track in the detector. Such events are not found. Assuming a uniform flux distribution of WIF particles coming from the atmosphere, the upper limit of their flux at the LVD site is 4.4 times rm 10^{-14} cm^{-2}sterad ^{-1}sec^{-1}. (Copies

  11. Comparison of tritiated-water standards by liquid scintillation for calibration of a new Standard Reference Material®.

    PubMed

    Collé, R; Laureano-Perez, L; Bergeron, D E

    2016-06-01

    A new National Institute of Standards and Technology (NIST) tritiated-water ((3)H-labeled oxidane) standard was prepared and calibrated. It is the 17th in a series of linked standards since 1954 and will be disseminated as Standard Reference Material® SRM 4927G, having a massic activity of 544.2kBqg(-1), with an expanded (k=2) relative standard uncertainty of 0.96%, at a Reference Time of 1200 EST, 1 May 2015. The calibration is based on relative liquid scintillation (LS) measurements using quench-varied efficiency tracing with two previous 1999 issues, viz., SRM 4927F and 4926E. Measurement comparisons were also made with respect to a 1994 tritiated-water French national standard and to a tritiated-water solution measured by 19 laboratories as part of an international measurement comparison organized by the Bureau International des Poids et Mesures (BIPM) in 2009. Confirmatory measurements for the massic activity of both SRM 4927F and 4927G by a triple-to-double coincidence ratio (TDCR) technique were also made. PMID:27010939

  12. Detectors on base of scintillation structures for registration of volumetric activities of gaseous and liquid media gamma radiation

    NASA Astrophysics Data System (ADS)

    Kadilin, V. V.; Yurov, V. N.; Ryabeva, E. V.; Samossadny, V. T.; Lupar, E. E.; Trofimov, Yu A.; Kolesnikov, S. V.; Chebishev, S. B.; Nebolsin, V. O.

    2016-02-01

    The main aim of this research is the development and prototyping of the ionizing radiation detectors for the diagnosis of the physical processes used for monitoring the radiation situation at the thermal or fast neutrons reactors. In this article we present the experimental verification of applicability of the scintillation detectors based on LaBr3(Ce) and YAlO3(Ce). The experimental studies of the gamma-ray detection with several designs of the crystal scintillation detectors in gas and liquid are considered. It was shown that the measurement range in the liquid medium at the duration of one measurement of 100 seconds for 137Cs equals from 3.79·102 Bq/l to 1.08·108 Bq/l for detector prototype based on YAlO3(Ce).

  13. Deuterated-xylene (xylene-d10; EJ301D): A new, improved deuterated liquid scintillator for neutron energy measurements without time-of-flight

    NASA Astrophysics Data System (ADS)

    Becchetti, F. D.; Raymond, R. S.; Torres-Isea, R. O.; Di Fulvio, A.; Clarke, S. D.; Pozzi, S. A.; Febbraro, M.

    2016-06-01

    In conjunction with Eljen Technology, Inc. (Sweetwater,TX) we have designed, constructed, and evaluated a 3 in. ×3 in. deuterated-xylene organic liquid scintillator (C8D10; EJ301D) as a fast neutron detector. Similar to deuterated benzene (C6D6; NE230, BC537, and EJ315) this scintillator can provide good pulse-shape discrimination between neutrons and gamma rays, has good timing characteristics, and can provide a light spectrum with peaks corresponding to discrete neutron energy groups up to ca. 20 MeV. Unlike benzene-based detectors, deuterated xylene is less volatile, less toxic, is not known to be carcinogenic, has a higher flashpoint, and hence is much safer for many applications. In addition EJ301D can provide slightly more light output and better PSD than deuterated-benzene scintillators. We show that, as with deuterated-benzene scintillators, the light-response spectra can be unfolded to provide useable neutron energy spectra without need for time-of-flight (ToF). An array of these detectors arranged at many angles close to a reaction target can be much more effective (×10 to ×100 or more) than an array of long-path ToF detectors which must utilize a narrowly-bunched and pulse-selected beam. As we demonstrate using a small Van de Graaff accelerator, measurements can thus be performed when a bunched and pulse-selected beam (as needed for time-of-flight) is not available.

  14. Getting the most from the detection of Galactic supernova neutrinos in future large liquid-scintillator detectors

    NASA Astrophysics Data System (ADS)

    Lu, Jia-Shu; Li, Yu-Feng; Zhou, Shun

    2016-07-01

    Future large liquid-scintillator detectors can be implemented to observe neutrinos from a core-collapse supernova in our Galaxy in various reaction channels: (1) the inverse beta decay ν¯ e+p →n +e+ , (2) the elastic neutrino-proton scattering ν +p →ν +p , (3) the elastic neutrino-electron scattering ν +e-→ν +e- , (4) the charged-current νe interaction νe+12C →e-+12N, (5) the charged-current ν¯ e interaction ν¯ e+12C →e++12B, and (6) the neutral-current interaction ν +12C →ν +12C* The less abundant 13C atoms in the liquid scintillator are also considered as a target, and both the charged-current interaction νe+13C →e-+13N and the neutral-current interaction ν +13C →ν +13C* are taken into account. In this work, we show for the first time that a global analysis of all these channels at a single liquid-scintillator detector, such as Jiangmen Underground Neutrino Observatory, is very important to test the average-energy hierarchy of supernova neutrinos and how the total energy is partitioned among neutrino flavors. In addition, the dominant channels for reconstructing neutrino spectra and the impact of other channels are discussed in great detail.

  15. Aging of LAB-based liquid scintillator in stainless steel containers

    NASA Astrophysics Data System (ADS)

    Chen, Hai-Tao; Yu, Bo-Xiang; Shan, Qing; Ding, Ya-Yun; Du, Bing; Liu, Shu-Tong; Zhang, Xuan; Zhou, Li; Jia, Wen-Bao; Fang, Jian; Ye, Xing-Chen; Hu, Wei; Niu, Shun-Li; Yan, Jia-Qing; Zhao, Hang; Hong, Dao-Jin

    2015-06-01

    Types 316 and 304 stainless steel are two candidates for the storage vessels and piping systems of LAB-based liquid scintillator (LS) in the JUNO experiment. LS aging experiments are carried out at temperatures of 40 °C and 25 °C. After 192 days aging at 40 °C, the attenuation length of LS was reduced by 6% in a glass container, 12% in a type 304 stainless steel tank, and 10% in a type 316 stainless steel tank. At 25 °C in 304 and 316 stainless steel tanks, the attenuation length was reduced by 6% after 307 days. The light yield and the absorption spectrum were practically the same as that of the unaged sample. The concentration of element Fe in the LAB-based LS did not show a clear change. Type 316 and 304 stainless steel can be used as vessels and transportation pipeline material for LAB-based LS. Supported by Strategic Priority Research Program of the Chinese Academy of Sciences (XDA10010500) and National Natural Science Foundation of China (11205183, 11005117, 11225525, 11390384)

  16. PSA discriminator influence on (222)Rn efficiency detection in waters by liquid scintillation counting.

    PubMed

    Stojković, Ivana; Todorović, Nataša; Nikolov, Jovana; Tenjović, Branislava

    2016-06-01

    A procedure for the (222)Rn determination in aqueous samples using liquid scintillation counting (LSC) was evaluated and optimized. Measurements were performed by ultra-low background spectrometer Quantulus 1220™ equipped with PSA (Pulse Shape Analysis) circuit which discriminates alpha/beta spectra. Since calibration procedure is carried out with (226)Ra standard, which has both alpha and beta progenies, it is clear that PSA discriminator has vital importance in order to provide precise spectra separation. Improvement of calibration procedure was done through investigation of PSA discriminator level and, consequentially, the activity of (226)Ra calibration standard influence on (222)Rn efficiency detection. Quench effects on generated spectra i.e. determination of radon efficiency detection were also investigated with quench calibration curve obtained. Radon determination in waters based on modified procedure according to the activity of (226)Ra standard used, dependent on PSA setup, was evaluated with prepared (226)Ra solution samples and drinking water samples with assessment of measurement uncertainty variation included. PMID:27016710

  17. Neutron light output response and resolution functions in EJ-309 liquid scintillation detectors

    SciTech Connect

    Enqvist, Andreas; Lawrence, Christopher C.; Wieger, Brian M.; Pozzi, Sara A.; Massey, Thomas N.

    2013-03-26

    Here, the neutron light output response functions and detector resolution functions were measured at Ohio University's tandem Van de Graaff generator for three cylindrical EJ-309 liquid scintillator cells, having dimensions 12.7(circle divide)-by-12.7, 7.6-by-7.6, and 7.6-by-5.1 cm. A 7.44 MeV deuteron beam was used on an Al-27 target generating a continuous spectrum over the energy range from a few hundred keV to over 10 MeV. The light output response functions are determined using an exponential fit. Detector resolution functions are obtained for the 12.7-by-12.7 and 7.6-by-7.6 cm detectors. It is demonstrated that the dependence on detector size is important for the light output response functions, but not to the same extent for the resolution function, even when photomultiplier tubes, detector material, and other detector characteristics are carefully matched.

  18. Development of a gadolinium-loaded liquid scintillator for the Hanaro short baseline prototype detector

    NASA Astrophysics Data System (ADS)

    Yeo, In Sung; Joo, Kyung Kwang; So, Sun Heang; Song, Sook Hyung; Kim, Hong Joo; So, Jung Ho; Park, Kang Soon; Ma, Kyung Ju; Jeon, Eun Ju; Kim, Jin Yu; Kim, Young Duk; Lee, Jason; Lee, Jeong-Yeon; Sun, Gwang-Min

    2014-02-01

    We propose a new experiment on the site of the Korea Atomic Energy Research Institute (KAERI) located at Daejeon, Korea. The Hanaro short baseline (SBL) nuclear reactor with a thermal power output 30 MW is used to investigate a reactor neutrino anomaly. A Hanaro SBL prototype detector having a 60- l volume has been constructed ˜6 m away from the reactor core. A gadolinium (Gd)-loaded liquid scintillator (LS) is used as an active material to trigger events. The selection of the LS is guided by physical and technical requirements, as well as safety considerations. A linear alkyl benzene (LAB) is used as a base solvent of the Hanaro SBL prototype detector. Three g/ l of PPO and 30 mg/ l of bis-MSB are dissolved to formulate the LAB-based LS. Then, a 0.5% gadolinium (Gd) complex with carboxylic acid is loaded into the LAB-based LS by using the liquidliquid extraction method. In this paper, we will summarize all the characteristics of the Gd-loaded LAB-based LS for the Hanaro prototype detector.

  19. Liquid scintillation counting of /sup 14/C for differentiation of synthetic ethanol from ethanol of fermentation

    SciTech Connect

    Martin, G.E.; Noakes, J.E.; Alfonso, F.C.; Figert, D.M.

    1981-09-01

    Samples containing ethanol are fractionated on a column so that the resultant ethanol content is > 93%. Determination of /sup 14/C by liquid scintillation counting on the ethanol fraction differentiates ethanol produced by fermentation from synthetic ethanol produced from fossil fuel sources. Twenty-seven samples were fractionated and analyzed for the /sup 14/C isotope. Six samples were synthetic ethanol derived from ethylene gas (direct and indirect process), and yielded a mean value for /sup 14/C isotope of 0.167 dpm/g carbon with a standard deviation (SD) of 0.066 dpm/g carbon (disintegrations per minute per gram of carbon). The remaining samples were ethanol derived from the fermentation of natural materials, such as corn, pear, sugar cane, grape, cherry, and blackberry, and yielded a mean value for /sup 14/C isotope of 16.11 dpm/g carbon with an SD of 1.27. The /sup 14/C values for specific mixtures of a synthetic and a natural ethanol compare favorably with the analytical values obtained by this procedure.

  20. Measurement of 90Sr in contaminated Fukushima soils using liquid scintillation counter.

    PubMed

    Kavasi, N; Sahoo, S K; Arae, H; Yoshida, S; Sorimachi, A; Tokonami, S

    2015-11-01

    A method based on liquid scintillation counting system has been developed for the measurement of (90)Sr in Fukushima soil samples due to contamination of (134)Cs and (137)Cs. Three soil samples were collected within 30 km radius from the Fukushima Daiichi Nuclear Power Plant (FDNPP). Activity concentration of (134)Cs and (137)Cs were measured using a gamma spectroscopy system with high-purity germanium detector. (90)Sr contamination is little elevated but comparable with the background contamination level that originated from atmospheric nuclear weapon tests, whereas radiocesium contamination has increased significantly. Activity concentration of (90)Sr in the soil samples varied in the range of 10.4±0.6-22.0±1.2 Bq kg(-1). Activity concentrations of (134)Cs and (137)Cs in the soil samples were in the range of 28.2±0.2-56.3±0.2 kBq kg(-1) and 35.2±0.1-70.2±0.2 kBq kg(-1), respectively (reference date for decay correction is 1 December 2011). PMID:25956786

  1. Discrimination of neutrons and γ-rays in liquid scintillator based on Elman neural network

    NASA Astrophysics Data System (ADS)

    Zhang, Cai-Xun; Lin, Shin-Ted; Zhao, Jian-Ling; Yu, Xun-Zhen; Wang, Li; Zhu, Jing-Jun; Xing, Hao-Yang

    2016-08-01

    In this work, a new neutron and γ (n/γ) discrimination method based on an Elman Neural Network (ENN) is proposed to improve the discrimination performance of liquid scintillator (LS) detectors. Neutron and γ data were acquired from an EJ-335 LS detector, which was exposed in a 241Am-9Be radiation field. Neutron and γ events were discriminated using two methods of artificial neural network including the ENN and a typical Back Propagation Neural Network (BPNN) as a control. The results show that the two methods have different n/γ discrimination performances. Compared to the BPNN, the ENN provides an improved of Figure of Merit (FOM) in n/γ discrimination. The FOM increases from 0.907 ± 0.034 to 0.953 ± 0.037 by using the new method of the ENN. The proposed n/γ discrimination method based on ENN provides a new choice of pulse shape discrimination in neutron detection. Supported by National Natural Science Foundation of China (11275134,11475117)

  2. Fast neutron measurement at Soudan Mine using a large liquid scintillation detector

    NASA Astrophysics Data System (ADS)

    Zhang, Chao; Mei, Dongming

    2014-03-01

    Characterizing neutron background is extremely important to the success of rare-event physics searching for neutrinoless double-beta decay and dark matter searches. Measuring the energy spectrum of fast neutrons for an underground laboratory is difficult and it requires intensive R&D for a given technology. EJ-301 liquid scintillator(known also as NE-213) is implemented as the target for a 12 liter neutron detector fabricated at the University of South Dakota. The light output response to atmospheric neutrons from a few MeV up to ~ 70 MeV has been calibrated for this detector. The detector has been taking data at Soudan Mine for over two years. We report the measured muon-induced neutrons in this paper. This work is supported in part by NSF PHY-0758120, PHYS-0919278, PHYS-0758120, PHYS-1242640, DOE grant DE-FG02-10ER46709, the Office of Research at the University of South Dakota and a 2010 research center support by the State of South Dakota.

  3. Standardization of 68Ge/68Ga Using Three Liquid Scintillation Counting Based Methods

    PubMed Central

    Zimmerman, B. E.; Cessna, J. T.; Fitzgerald, R.

    2008-01-01

    A solution containing 68Ge in equilibrium with its daughter, 68Ga, has been standardized for the first time at the National Institute of Standards and Technology (NIST) using 3 liquid scintillation-based techniques: live-timed 4πβ -γ anticoincidence (LTAC) counting, the Triple-to-Double Coincidence Ratio (TDCR) method, and 3H-standard efficiency tracing with the CIEMAT1/NIST (CNET) method. The LTAC technique is much less dependent on level scheme data and model-dependent parameters and was thus able to provide a reference activity concentration value for the master solution with a combined standard uncertainty of about 0.3 %. The other two methods gave activity concentration values with respective differences from the reference value of +1.2 % and −1.5 %, which were still within the experimental uncertainties. Measurements made on the NIST “4π”γ secondary standard ionization chamber allowed for the determination of calibration factors for that instrument, allowing future calibrations to be made for 68Ge/68Ga without the need for a primary measurement. The ability to produce standardized solutions of 68Ge presents opportunities for the development of a number of NIST-traceable calibration sources with very low (<1 %) relative standard uncertainties that can be used in diagnostic medical imaging. PMID:27096126

  4. Diffusivity measurements in polymers: II. Residual casting solvent measurement by liquid scintillation counting

    NASA Astrophysics Data System (ADS)

    Gardiner, Allen B.; Qin, Anwei; Henderson, Clifford L.; Pancholi, Sanju; Koros, William J.; Willson, C. Grant; Dammel, Ralph R.; Mack, Chris A.; Hinsberg, William D.

    1997-07-01

    Simulation of the microlithographic process plays an increasingly important role in the manufacturing of integrated circuitry. Unfortunately, most lithography simulations still lack fundamental relationships that link the resist chemistry and the final resist image. This study is directed towards generating the data necessary to quantify one of these relationships, the effect of residual casting solvent on the resist image. The amount of casting solvent was measured as a function of the post apply bake temperature and time for several casting solvents directly by using liquid scintillation counting. These measurements were carried out on four identical diazonaphthoquinone-novolac resist formulations cast with different radio-labeled casting solvents (ethyl cellosolve acetate, PGMEA, diglyme, and ethyl lactate). From these data we have estimated the diffusion coefficients for the solvents and the dependence of these coefficients on temperature. These data are then convolved with dissolution parameters and Dill parameters to isolate and establish the relationships between these parameters and the post apply bake process that controls the amount of residual casting solvent.

  5. Simulation study of the neutron-gamma discrimination capability of a liquid scintillator neutron detector

    NASA Astrophysics Data System (ADS)

    Xing, Haoyang; Yu, Xunzhen; Zhu, Jingjun; Wang, Li; Ma, Jinglu; Liu, Shukui; Li, Linwei; Chen, Liejian; Tang, Changjian; Yue, Qian

    2014-12-01

    The capability to discriminate between neutrons and gamma rays (n/γ) by means of their pulse shapes is important for many users of liquid scintillator (LS) neutron detectors. To simulate the n/γ discrimination capability of a neutron detector, we have developed a method to simulate the pulse signal generated by an incident n or γ in the LS. Light pulses caused by ionization and excitation from incident n or γ radiation are simulated by the Geant4 simulation package based on the geometry and materials of a prototype LS detector. The response to the incident light of the photomultiplier tube (PMT) and data acquisition (DAQ) circuit was obtained from a single photoelectron experiment. The final output signal from a detector was produced by convolving its light pulse with the response function of the PMT and DAQ. Two methods, the charge comparison method (CCM) and the pulse gradient method (PGM), were applied to discriminate the simulated signals. The simulation was validated by comparing its result to an experimental result from the prototype LS detector. Our method can be applied in the design of an LS detector, which has subsequently been optimized n/γ discrimination. The method can also be helpful to analyze experimental data and evaluate the performance of n/γ discrimination techniques.

  6. Method to determine 226Ra in small sediment samples by ultralow background liquid scintillation.

    PubMed

    Sanchez-Cabeza, Joan-Albert; Kwong, Laval Liong Wee; Betti, Maria

    2010-08-15

    (210)Pb dating of sediment cores is a widely used tool to reconstruct ecosystem evolution and historical pollution during the last century. Although (226)Ra can be determined by gamma spectrometry, this method shows severe limitations which are, among others, sample size requirements and counting times. In this work, we propose a new strategy based on the analysis of (210)Pb through (210)Po in equilibrium by alpha spectrometry, followed by the determination of (226)Ra (base or supported (210)Pb) without any further chemical purification by liquid scintillation and with a higher sample throughput. Although gamma spectrometry might still be required to determine (137)Cs as an independent tracer, the effort can then be focused only on those sections dated around 1963, when maximum activities are expected. In this work, we optimized the counting conditions, calibrated the system for changing quenching, and described the new method to determine (226)Ra in small sediment samples, after (210)Po determination, allowing a more precise determination of excess (210)Pb ((210)Pb(ex)). The method was validated with reference materials IAEA-384, IAEA-385, and IAEA-313. PMID:20704374

  7. 234Th analysis of marine sediments via extraction chromatography and liquid scintillation counting.

    PubMed

    Nour, Svetlana; Burnett, William C; Horwitz, E Philip

    2002-08-01

    234Th is widely used as a natural tracer for study of biological mixing and particle scavenging processes in the ocean. This naturally occurring nuclide serves this purpose due to its convenient half-life (24.1 days), constant rate of production from 238U dissolved in seawater, and its strong tendency to attach to particles in seawater. As a beta/gamma emitter, 234Th may be determined using low-level gas-flow proportional counting, gamma spectrometry, and liquid scintillation counting (LSC). We describe here a technique which combines Cerenkov counting to evaluate 234Th (via 234Pa) with LSC alpha counting of 230Th added to the samples as a yield tracer. Our separation approach is based on a sample preparation procedure for marine sediments using nitric acid leaching in a "hot block", and extraction chromatography (TEVA x Resin) for Th isolation. Samples are counted in plastic LSC vials, using Ultima Gold AB cocktail, in 1 M H3PO4 media. A series of sediment samples spiked with known amounts of 234Th yielded activities within a few percent of the anticipated values. PMID:12150283

  8. Neutron light output response and resolution functions in EJ-309 liquid scintillation detectors

    DOE PAGESBeta

    Enqvist, Andreas; Lawrence, Christopher C.; Wieger, Brian M.; Pozzi, Sara A.; Massey, Thomas N.

    2013-03-26

    Here, the neutron light output response functions and detector resolution functions were measured at Ohio University's tandem Van de Graaff generator for three cylindrical EJ-309 liquid scintillator cells, having dimensions 12.7(circle divide)-by-12.7, 7.6-by-7.6, and 7.6-by-5.1 cm. A 7.44 MeV deuteron beam was used on an Al-27 target generating a continuous spectrum over the energy range from a few hundred keV to over 10 MeV. The light output response functions are determined using an exponential fit. Detector resolution functions are obtained for the 12.7-by-12.7 and 7.6-by-7.6 cm detectors. It is demonstrated that the dependence on detector size is important for themore » light output response functions, but not to the same extent for the resolution function, even when photomultiplier tubes, detector material, and other detector characteristics are carefully matched.« less

  9. Evaluation of 2-PI liquid scintillation whole body counter using MCNP

    NASA Astrophysics Data System (ADS)

    Mireles-Garcia, Fernando

    The 2-pi liquid scintillation whole body counter (WBC) at the University of Missouri-Columbia has been evaluated using MCNP-4A (a general Monte Carlo Neutron-Photon transport code, Version 4A). This facility is of importance to a wide variety of applications, such as determination of body fat content in human and animal subjects and measurement of radioactive tracers in animals. Phantoms and mathematical models were used in this research to upgrade the calibration procedures of the WBC. Since the existing protocol assumes a simple efficiency calibration based only upon body mass, it does not account for body shape and gives no methodology for placement of the subject below the detectors. Mathematical models were developed to calculate geometry efficiency for a variety of subjects and geometries utilizing the MCNP-4A transport code. Comparison of the results from simulation with experimental data shows excellent agreement not only in the shape of the curves as a function of subject position but also in absolute magnitude. In the case of the WBC and a phantom consisting of 40 liters of water containing 800 grams of sp+K the error in the magnitude is within 6%, which is easily attributable to the experimental calibration of the detectors. The efficiency of the WBC has been calculated for different weights for modified Adam-E through Adam-L model geometries; hence weight and shape can be modeled carefully and correction can be applied to actual human measurements based upon this work.

  10. Comparative study of large samples (2" × 2") plastic scintillators and EJ309 liquid with pulse shape discrimination (PSD) capabilities

    NASA Astrophysics Data System (ADS)

    Iwanowska-Hanke, J.; Moszynski, M.; Swiderski, L.; Sibczynski, P.; Szczesniak, T.; Krakowski, T.; Schotanus, P.

    2014-06-01

    In the paper we reported on the scintillation properties and pulse shape discrimination (PSD) performance of new plastic scintillators. The samples with dimension of 2 inches × 2 inches were tested: EJ299-34, EJ299-34G, EJ299-33 and EJ299-33G. They are the first commercially available plastics with neutron/gamma discrimination properties. The paper covers the measurements of emission spectra, photoelectron yield, analysis of the light pulse shapes originating from events related to gamma-rays and fast neutrons as well as neutron/gamma discrimination. The tested plastics are characterized by a photoelectron yield on a level of approximately 1600-2500 phe/MeV, depending on the sample. The highest value, measured for EJ299-34, is similar to the number of photoelectrons measured for EJ309 (2600 phe/MeV). The figure of merit (FOM) calculated for narrow energy cuts — indicating the PSD performance — showed that the PSD capabilities of the plastics are significantly lower than of EJ309. These scintillators are still under development in order to optimize the composition and manufacturing procedures. At this time the results obtained with the new plastics suggest their possible use as an alternative for liquid scintillators, especially if we consider their inflammability and non-toxicity.

  11. Calibration of a liquid scintillation counter for alpha, beta and Cerenkov counting

    SciTech Connect

    Scarpitta, S.C.; Fisenne, I.M.

    1996-07-01

    Calibration data are presented for 25 radionuclides that were individually measured in a Packard Tri-Carb 2250CA liquid scintillation (LS) counter by both conventional and Cerenkov detection techniques. The relationships and regression data between the quench indicating parameters and the LS counting efficiencies were determined using microliter amounts of tracer added to low {sup 40}K borosilicate glass vials containing 15 mL of Insta-Gel XF scintillation cocktail. Using {sup 40}K, the detection efficiencies were linear over a three order of magnitude range (10 - 10,000 mBq) in beta activity for both LS and Cerenkov counting. The Cerenkov counting efficiency (CCE) increased linearly (42% per MeV) from 0.30 to 2.0 MeV, whereas the LS efficiency was >90% for betas with energy in excess of 0.30 MeV. The CCE was 20 - 50% less than the LS counting efficiency for beta particles with maximum energies in excess of 1 MeV. Based on replicate background measurements, the lower limit of detection (LLD) for a 1-h count at the 95% confidence level, using water as a solvent, was 0.024 counts sec-{sup -1} and 0.028 counts sec-1 for plastic and glass vials, respectively. The LLD for a 1-h-count ranged from 46 to 56 mBq (2.8 - 3.4 dpm) for both Cerenkov and conventional LS counting. This assumes: (1) a 100% counting efficiency, (2) a 50% yield of the nuclide of interest, (3) a 1-h measurement time using low background plastic vials, and (4) a 0-50 keV region of interest. The LLD is reduced an order of magnitude when the yield recovery exceeds 90% and a lower background region is used (i.e., 100 - 500 keV alpha region of interest). Examples and applications of both Cerenkov and LS counting techniques are given in the text and appendices.

  12. Automatic in-syringe dispersive liquid-liquid microextraction of ⁹⁹Tc from biological samples and hospital residues prior to liquid scintillation counting.

    PubMed

    Villar, Marina; Avivar, Jessica; Ferrer, Laura; Borràs, Antoni; Vega, Fernando; Cerdà, Víctor

    2015-07-01

    A new approach exploiting in-syringe dispersive liquid-liquid microextraction (DLLME) for (99)Tc extraction and preconcentration from biological samples, i.e., urine and saliva, and liquid residues from treated patients is presented. (99)Tc is a beta emitter with a long half-life (2.111 × 10(5) years) and mobility in the different environmental compartments. One of the sources of this radionuclide is through the use of its father (99m)Tc in medical diagnosis. For the first time a critical comparison between extractants and disperser solvents for (99)Tc DLLME is presented, e.g., tributyl phosphate (TBP), trioctylmethylammonium chloride (Aliquat®336), triisooctylamine (TiOA), as extractants in apolar solvents such as xylene and dodecane, and disperser solvents such as acetone, acetonitrile, ethanol, methanol, 1-propanol, and 2-propanol. The system was optimized by experimental design, and 22.5% of Aliquat®336 in acetone was selected as extractant and disperser, respectively. Off-line detection was performed using a liquid scintillation counter. The present method has a (99)Tc minimum detectable activity (MDA) of 0.075 Bq with a high extraction/preconcentration frequency (8 h(-1)). Urine, saliva, and hospital residues were satisfactorily analyzed with recoveries of 82-119%. Thus, the proposed system is an automatic powerful tool to monitor the entry of (99)Tc into the environment. Graphical Abstract (99m)Tc is widely used in Nuclear Medicine for diagnosis. Its daugther (99)Tc is automatically monitored in biological samples from treated patients by in-syringe dispersive liquid-liquid microextraction. PMID:26007698

  13. Simultaneous determination of 226Ra, 233U and 237Np by liquid scintillation spectrometry.

    PubMed

    Nebelung, Cordula; Baraniak, Lutz

    2007-02-01

    A method has been developed for the simultaneous determination of 226Ra, 233U and 237Np by liquid-scintillation (LS) spectrometry. This method consists of the evaluation of the alpha-spectrum that is composed of the strongly overlapping peaks of 226Ra, 233U, 237Np, 222Rn and 218Po in the energy range of 4.60-6.00 MeV and the single 214Po peak at 7.69 MeV. The alpha-peaks are analysed by a special peak fit function that considers the deviation of the alpha-peak at the low energy side from the pure Gaussian shape. First 237Np is determined using its daughter 233Pa by analysing the beta-spectrum in the range 150-570 keV. 226Ra follows from the alpha-spectrum that is measured 6 weeks after sample preparation, i.e., 226Ra is determined from the radioactive equilibrium with its short-lived daughters 222Rn, 218Po and 214Po. Finally the 233U activity results from the fitted spectrum in the range of 4.4-4.8 MeV by subtracting the activity of 226Ra and 237Np. Knowing the exact energy position of the LS-peaks an alternative evaluation consists in the accurate deconvolution of the first three peaks that are formed by 226Ra and 233U (maximum of both at channel 700), 237Np (maxima at channels 700 and 725) and 222Rn (maximum at channel 737). In these two ways 226Ra, 233U and 237Np can be determined in mutual activity ratios of 1:50 with a relative standard deviation of less than 4% for the major activity and 9% for the minor activity. PMID:17142052

  14. Study of annual modulation at Soudan Mine using a liquid scintillation detector

    NASA Astrophysics Data System (ADS)

    Zhang, Chao; Mei, Dongming

    2015-04-01

    The phenomenon of annual modulation is believed to be one of signatures induced by Weakly Interacting Massive Particles(WIMPs) through elastic scattering off nucleus in the target for direct dark matter searches. Both DAMA and CoGeNT experiments have claimed the discovery of dark matter in terms of annual modulation while many other experiments have ruled out the entire claimed region. However, the sources that caused the annual modulation in DAMA and CoGeNT are till mysterious. A 12-liter liquid scintillation detector has been running at Soudan Mine (1.95 km.w.e) for several years. Using this detector, muon and muon-induced neutron fluxes at Soudan Mine are measured to be (1 . 65 +/- 0 . 02(sta .) +/- 0 . 1(sys .)) × 10-7 cm-2 s-1 (Eμ > 1 GeV) and (2 . 23 +/- 0 . 52(sta .) +/- 0 . 99(sys .)) ×10-9 cm-2 s-1 (En > 20 MeV), respectively. Data analysis for three years shows a clear annual modulation pattern (E > 10 MeV) caused by cosmic-ray muons with an amplitude of ~ 2%. The annual modulation caused by radon has also been observed in the energy region below 10 MeV. We demonstrate the sources of annual modulation in different energy region and explain how background-induced annual modulation may mimic dark matter signature. This work is supported by NSF in part by the NSF PHY-0758120 and 1242640, DOE Grant DE-FG02-10ER46709, and the State of South Dakota.

  15. NOCHAR Polymers: An Aqueous and Organic Liquid Solidification Process for Cadarache LOR (Liquides Organiques Radioactifs) - 13195

    SciTech Connect

    Vaudey, Claire-Emilie; Renou, Sebastien; Porco, Julien; Kelley, Dennis; Cochaud, Chantal

    2013-07-01

    To handle the Very Low Level Waste (VLLW) and the Low Level Waste (LLW) in France, two options can be considered: the incineration at CENTRACO facility and the disposal facility on ANDRA sites. The waste acceptance in these radwaste routes is dependent upon the adequacy between the waste characteristics (physical chemistry and radiological) and the radwaste route specifications. If the waste characteristics are incompatible with the radwaste route specifications (presence of significant quantities of chlorine, fluorine, organic component etc or/and high activity limits), it is necessary to find an alternative solution that consists of a waste pre-treatment process. In the context of the problematic Cadarache LOR (Liquides Organiques Radioactifs) waste streams, two radioactive scintillation cocktails have to be treated. The first one is composed of organic liquids at 13.1 % (diphenyloxazol, mesitylene, TBP, xylene) and water at 86.9 %. The second one is composed of TBP at 8.6 % and water at 91.4 %. They contain chlorine, fluorine and sulphate and have got alpha/beta/gamma spectra with mass activities equal to some kBq.g{sup -1}. Therefore, tritium is present and creates the second problematic waste stream. As a consequence, in order for disposal acceptance at the ANDRA site, it is necessary to pre-treat the waste. The NOCHAR polymers as an aqueous and organic liquid solidification process seem to be an adequate solution. Indeed, these polymers constitute an important variety of products applied to the treatment of radioactive aqueous and organic liquids (solvent, oil, solvent/oil mixing etc) and sludge through a mechanical and chemical solidification process. For Cadarache LOR, N910 and N960 respectively dedicated to the organic and aqueous liquids solidification are considered. With the N910, the organic waste solidification occurs in two steps. As the organic liquid travels moves through the polymer strands, the strands swell and immobilise the liquid. Then as the

  16. Ionic Liquid Extractions of Soil Organic Matter

    NASA Astrophysics Data System (ADS)

    Patti, Antonio; Macfarlane, Douglas; Clarke, Michael

    2010-05-01

    A large range of ionic liquids with the ability to dissolve different classes of natural biopolymers (e.g. cellulose, lignin, protein) have been reported in the literature. These have the potential to isolate different fractions of soil organic matter, thus yielding novel information that is not available through other extraction procedures. The ionic liquids dimethylammonium dimethylcarbamate (DIMCARB), alkylbenzenesulfonate and 1-butyl-3methylimidazolium chloride (Bmim Cl) can solubilise selected components of soil organic matter. Soil extractions with these materials showed that the organic matter recovered showed chemical properties that were consistent with humic substances. These extracts had a slightly different organic composition than the humic acids extracted using the traditional International Humic Substances Society (IHSS) method. The ionic liquids also solubilised some inorganic matter from the soil. Humic acids recovered with alkali were also partially soluble in the ionic liquids. DIMCARB appeared to chemically interfere with organic extract, increasing the level of nitrogen in the sample. It was concluded that the ionic liquid Bmim Cl may function as a useful solvent for SOM, and may be used to recover organic matter of a different character to that obtained with alkali

  17. A measurement of the absorption of liquid argon scintillation light by dissolved nitrogen at the part-per-million level

    NASA Astrophysics Data System (ADS)

    Jones, B. J. P.; Chiu, C. S.; Conrad, J. M.; Ignarra, C. M.; Katori, T.; Toups, M.

    2013-07-01

    We report on a measurement of the absorption length of scintillation light in liquid argon due to dissolved nitrogen at the part-per-million (ppm) level. We inject controlled quantities of nitrogen into a high purity volume of liquid argon and monitor the light yield from an alpha source. The source is placed at different distances from a cryogenic photomultiplier tube assembly. By comparing the light yield from each position we extract the absorption cross section of nitrogen. We find that nitrogen absorbs argon scintillation light with strength of (1.51±0.15) × 10-4 cm-1ppm-1, corresponding to an absorption cross section of (4.99±0.51) × 10-21 cm2molecule-1. We obtain the relationship between absorption length and nitrogen concentration over the 0 to 50 ppm range and discuss the implications for the design and data analysis of future large liquid argon time projection chamber (LArTPC) detectors. Our results indicate that for a current-generation LArTPC, where a concentration of 2 parts per million of nitrogen is expected, the attenuation length due to nitrogen will be 30±3 meters.

  18. Results of low energy background measurements with the Liquid Scintillation Detector (LSD) of the Mont Blanc Laboratory

    NASA Technical Reports Server (NTRS)

    Aglietta, M.; Badino, G.; Bologna, G. F.; Castagnoli, C.; Fulgione, W.; Galeotti, P.; Saavedra, O.; Trinchero, G. C.; Vernetto, S.; Dadykin, V. L.

    1985-01-01

    The 90 tons liquid scintillation detector (LSD) is fully running since October 1984, at a depth of 5,200 hg/sq cm of standard rock underground. The main goal is to search for neutrino bursts from collapsing stars. The experiment is very sensitive to detect low energy particles and has a very good signature to gamma-rays from (n,p) reaction which follows the upsilon e + p yields n + e sup + neutrino capture. The analysis of data is presented and the preliminary results on low energy measurements are discussed.

  19. Scintillation proximity assay using polymeric membranes

    SciTech Connect

    Mansfield, R.K.

    1992-01-01

    Liquid scintillation counting (LSC) is typically used to quantify electron emitting isotopes. In LSC, radioactive samples are dissolved in an organic fluor solution (scintillation cocktail) to ensure that the label is close enough to the fluor molecules to be detected. Although efficient, scintillation cocktail is neither specific or selective for samples labeled with the same radioisotope. Scintillation cocktail is flammable posing significant health risks to the user and is expensive to purchase and discard. Scintillation Proximity Assay (SPA) is a radioanalytical technique where only those radiochemical entities (RCE's) bound to fluor containing matrices are detected. Only bound RCE's are in close enough proximity the entrapped fluor molecules to induce scintillations. Unbound radioligands are too far removed from the fluor molecules to be detected. The research in this dissertation focused on the development and evaluation of fluor-containing membranes (scintillation proximity membranes, SP membranes) to be used for specific radioanalytical techniques without using scintillation cocktail. Polysulfone and PVC SP membranes prepared in our laboratory were investigated for radioimmunossay (RIA) where only bound radioligand is detected, thereby eliminating the separation step impeding the automation of RIA. These SP membranes performed RIA where the results were nearly identical to commercial SP microbeads. SP membranes functionalized with quaternary ammonium hydroxide moieties were able to trap and quantify [sup 14]CO[sub 2] without using liquid scintillation cocktail. RCE's bound in the pore structure of SP membranes are intimate with the entrapped fluor providing the geometry needed for high detection efficiencies. Absorbent SP membranes were used in radiation surveys and were shown to be as effective as conventional survey techniques using filter paper and scintillation cocktail.

  20. Digital discrimination of neutrons and gamma-rays in organic scintillation detectors using moment analysis

    NASA Astrophysics Data System (ADS)

    Xie, Xufei; Zhang, Xing; Yuan, Xi; Chen, Jinxiang; Li, Xiangqing; Zhang, Guohui; Fan, Tieshuan; Yuan, Guoliang; Yang, Jinwei; Yang, Qingwei

    2012-09-01

    Digital discrimination of neutron and gamma-ray events in an organic scintillator has been investigated by moment analysis. Signals induced by an americium-beryllium (Am/Be) isotropic neutron source in a stilbene crystal detector have been sampled with a flash analogue-to-digital converter (ADC) of 1 GSamples/s sampling rate and 10-bit vertical resolution. Neutrons and gamma-rays have been successfully discriminated with a threshold corresponding to gamma-ray energy about 217 keV. Moment analysis has also been verified against the results assessed by a time-of-flight (TOF) measurement. It is shown that the classification of neutrons and gamma-rays afforded by moment analysis is consistent with that achieved by digital TOF measurement. This method has been applied to analyze the data acquired from the stilbene crystal detector in mixed radiation field of the HL-2A tokamak deuterium plasma discharges and the results are described.

  1. Digital discrimination of neutrons and gamma-rays in organic scintillation detectors using moment analysis

    SciTech Connect

    Xie Xufei; Zhang Xing; Yuan Xi; Chen Jinxiang; Li Xiangqing; Zhang Guohui; Fan Tieshuan; Yuan Guoliang; Yang Jinwei; Yang Qingwei

    2012-09-15

    Digital discrimination of neutron and gamma-ray events in an organic scintillator has been investigated by moment analysis. Signals induced by an americium-beryllium (Am/Be) isotropic neutron source in a stilbene crystal detector have been sampled with a flash analogue-to-digital converter (ADC) of 1 GSamples/s sampling rate and 10-bit vertical resolution. Neutrons and gamma-rays have been successfully discriminated with a threshold corresponding to gamma-ray energy about 217 keV. Moment analysis has also been verified against the results assessed by a time-of-flight (TOF) measurement. It is shown that the classification of neutrons and gamma-rays afforded by moment analysis is consistent with that achieved by digital TOF measurement. This method has been applied to analyze the data acquired from the stilbene crystal detector in mixed radiation field of the HL-2A tokamak deuterium plasma discharges and the results are described.

  2. Design of organic scintillators for non-standard radiation field dosimetry: experimental setup.

    PubMed

    Norman H, Machado R; Maximiliano, Trujillo T; Javier E, García G; Diana C, Narvaez G; Paula A, Marín M; Róbinson A, Torres V

    2013-01-01

    This paper describes an experimental setup designed for sensing the luminescent light coming from an organic plastic scintillator stimulated with ionizing radiation. This device is intended to be a part of a complete dosimeter system for characterization of small radiation fields which is the project of the doctoral thesis of the medical physicist at the Radiation Oncology facility of Hospital San Vicente Fundación in conjunction with the Universidad de Antioquia of Medellín Colombia. Some preliminary results predict a good performance of the unit, but further studies must be conducted in order to have a completed evaluation of the system. This is the first step in the development of an accuracy tool for measurement of non-standard fields in the Radiotherapy or Radiosurgery processes. PMID:24110369

  3. Digital discrimination of neutrons and gamma-rays in organic scintillation detectors using moment analysis.

    PubMed

    Xie, Xufei; Zhang, Xing; Yuan, Xi; Chen, Jinxiang; Li, Xiangqing; Zhang, Guohui; Fan, Tieshuan; Yuan, Guoliang; Yang, Jinwei; Yang, Qingwei

    2012-09-01

    Digital discrimination of neutron and gamma-ray events in an organic scintillator has been investigated by moment analysis. Signals induced by an americium-beryllium (Am/Be) isotropic neutron source in a stilbene crystal detector have been sampled with a flash analogue-to-digital converter (ADC) of 1 GSamples/s sampling rate and 10-bit vertical resolution. Neutrons and gamma-rays have been successfully discriminated with a threshold corresponding to gamma-ray energy about 217 keV. Moment analysis has also been verified against the results assessed by a time-of-flight (TOF) measurement. It is shown that the classification of neutrons and gamma-rays afforded by moment analysis is consistent with that achieved by digital TOF measurement. This method has been applied to analyze the data acquired from the stilbene crystal detector in mixed radiation field of the HL-2A tokamak deuterium plasma discharges and the results are described. PMID:23020376

  4. Scintillation properties of polycrystalline LaxY1-xO3 ceramic

    NASA Astrophysics Data System (ADS)

    Sahi, Sunil; Chen, Wei; Kenarangui, Rasool

    2015-03-01

    Scintillators are the material that absorbs the high-energy photons and emits visible photons. Scintillators are commonly used in radiation detector for security, medical imaging, industrial applications and high energy physics research. Two main types of scintillators are inorganic single crystals and organic (plastic or liquid) scintillators. Inorganic single crystals are expensive and difficult to grow in desire shape and size. Also, some efficient inorganic scintillator such as NaI and CsI are not environmental friendly. But on the other hand, organic scintillators have low density and hence poor energy resolution which limits their use in gamma spectroscopy. Polycrystalline ceramic can be a cost effective alternative to expensive inorganic single crystal scintillators. Here we have fabricated La0.2Y1.8O3 ceramic scintillator and studied their luminescence and scintillation properties. Ceramic scintillators were fabricated by vacuum sintering of La0.2Y1.8O3 nanoparticles at temperature below the melting point. La0.2Y1.8O3 ceramic were characterized structurally using XRD and TEM. Photoluminescence and radioluminescence studies were done using UV and X-ray as an excitation source. We have used gamma isotopes with different energy to studies the scintillation properties of La0.2Y1.8O3 scintillator. Preliminary studies of La0.2Y1.8O3 scintillator shows promising result with energy resolution comparable to that of NaI and CsI.

  5. Characteristic parameters in the measurement of (14)C of biobased diesel fuels by liquid scintillation.

    PubMed

    Idoeta, R; Pérez, E; Herranz, M; Legarda, F

    2014-11-01

    The direct method based on the radiocarbon content present in modern-day materials used for the quantification of the renewable origin component in diesel has been analysed in order to establish the best sample preparation and measuring conditions that minimise the limit of detection. The scintillation cocktail and the diesel/cocktail ratio have been optimised. PMID:24560852

  6. Delayed light emission of Tetraphenyl-butadiene excited by liquid argon scintillation light. Current status and future plans

    NASA Astrophysics Data System (ADS)

    Segreto, E.; Machado, A. A.; Araujo, W.; Teixeira, V.

    2016-02-01

    Tetraphenyl-butadiene is the wavelength shifter most widely used in combination with liquid argon. The latter emits scintillation photons with a wavelength of 127 nm that need to be downshifted to be detected by photomultipliers with glass or quartz windows. Tetraphenyl-butadiene has been demonstrated to have an extremely high conversion efficiency, possibly higher than 100% for 127 nm photons, while there is no precise information about the time dependence of its emission. It is usually assumed to be exponentially decaying with a characteristic time of the order of one ns, as an extrapolation from measurements with exciting radiation in the near UV . This work shows that tetraphenyl-butadiene, when excited by 127 nm photons, re-emits photons not only with a very short decay time, but also with slower ones due to triplet states de-excitations. This fact can strongly contribute to clarifying the anomalies in liquid-argon scintillation light reported in the literature since the 1970s. Precision measurements of the properties of TPB, when excited by Vacuum Ultra Violet photons are being carried on at the Brazilian Synchrotron Light Laboratory in Campinas (State of São Paulo).

  7. Digital pulse shape discrimination methods for n-γ separation in an EJ-301 liquid scintillation detector

    NASA Astrophysics Data System (ADS)

    Wan, Bo; Zhang, Xue-Ying; Chen, Liang; Ge, Hong-Lin; Ma, Fei; Zhang, Hong-Bin; Ju, Yong-Qin; Zhang, Yan-Bin; Li, Yan-Yan; Xu, Xiao-Wei

    2015-11-01

    A digital pulse shape discrimination system based on a programmable module NI-5772 has been established and tested with an EJ-301 liquid scintillation detector. The module was operated by running programs developed in LabVIEW, with a sampling frequency up to 1.6 GS/s. Standard gamma sources 22Na, 137Cs and 60Co were used to calibrate the EJ-301 liquid scintillation detector, and the gamma response function was obtained. Digital algorithms for the charge comparison method and zero-crossing method have been developed. The experimental results show that both digital signal processing (DSP) algorithms can discriminate neutrons from γ-rays. Moreover, the zero-crossing method shows better n-γ discrimination at 80 keVee and lower, whereas the charge comparison method gives better results at higher thresholds. In addition, the figure-of-merit (FOM) for detectors of two different dimensions were extracted at 9 energy thresholds, and it was found that the smaller detector presented better n-γ separation for fission neutrons. Supported by National Natural Science Foundation of China (91226107, 11305229) and the Strategic Priority Research Program of the Chinese Academy of Sciences (XDA03030300)

  8. Neutron detector based on Particles of 6Li glass scintillator dispersed in organic lightguide matrix

    NASA Astrophysics Data System (ADS)

    Ianakiev, K. D.; Hehlen, M. P.; Swinhoe, M. T.; Favalli, A.; Iliev, M. L.; Lin, T. C.; Bennett, B. L.; Barker, M. T.

    2015-06-01

    Most 3He replacement neutron detector technologies today have overlapping neutron-gamma pulse-height distributions, which limits their usefulness and performance. Different techniques are used to mitigate this shortcoming, including Pulse Shape Discrimination (PSD) or threshold settings that suppress all gammas as well as much of the neutrons. As a result, count rates are limited and dead times are high when PSD is used, and the detection efficiency for neutron events is reduced due to the high threshold. This is a problem in most applications where the neutron-gamma separation of 3He detectors had been essential. This challenge is especially severe for neutron coincidence and multiplicity measurements that have numerous conflicting requirements such as high detection efficiency, short die-away time, short dead time, and high stability. 6Li-glass scintillators have excellent light output and a single peak distribution, but they are difficult to implement because of their gamma sensitivity. The idea of reducing the gamma sensitivity of 6Li-glass scintillators by embedding small glass particles in an organic light-guide medium was first presented by L.M. Bollinger in the early 60s but, to the best of our knowledge, has never been reduced to practice. We present a proof of principle detector design and experimental data that develop this concept to a large-area neutron detector. This is achieved by using a multi-component optical medium (6Li glass particles attached to a glass supporting structure and a mineral oil light guide) which matches the indices of refraction and minimizes the absorption of the 395 nm scintillator light. The detector design comprises a 10 in. long tube with dual end readout with about 3% volume density of 6Li glass particles installed. The presented experimental data with various neutron and gamma sources show the desired wide gap between the neutron and gamma pulse height distributions, resulting in a true plateau in the counting

  9. Energy Transfer Based Nanocomposite Scintillator for Radiation Detection

    NASA Astrophysics Data System (ADS)

    Aslam, Soha; Sahi, Sunil; Chen, Wei; Ma, Lun; Kenarangui, Rasool

    2014-09-01

    Scintillators are the materials that emit light upon irradiation with high energy radiation like X-ray or gamma-ray. Inorganic single crystal and organic (plastic and liquid) are the two most used scintillator types. Both of these scintillator kinds have advantages and disadvantages. Inorganic single crystals are expensive and difficult to grow in desire shape and size. Also, single crystal scintillator such as NaI and CsI are very hygroscopic. On the other hand, organic scintillators have low density which limits their applications in gamma spectroscopy. Due to high quantum yield and size dependent emission, nanoparticles have attracted interested in various field of research. Here, we have studies the nanoparticles for radiation detection. We have synthesized nanoparticles of Cerium fluoride (CeF3), Zinc Oxide (ZnO), Cadmium Telluride (CdTe), Copper complex and Zinc sulfide (ZnS). We have used Fluorescence Resonance Energy Transfer (FRET) principle to enhance the luminescence properties of nanocomposite scintillator. Nanocomposites scintillators are structurally characterized with X-ray diffraction (XRD) and Transmission Electron Microscopy (TEM). Optical properties are studied using Photoluminescence, UV-Visible and X-ray. Enhancements in the luminescence are observed under UV and X-ray excitation. Preliminary studies shows nanocomposite scintillators are promising for radiation detection. Scintillators are the materials that emit light upon irradiation with high energy radiation like X-ray or gamma-ray. Inorganic single crystal and organic (plastic and liquid) are the two most used scintillator types. Both of these scintillator kinds have advantages and disadvantages. Inorganic single crystals are expensive and difficult to grow in desire shape and size. Also, single crystal scintillator such as NaI and CsI are very hygroscopic. On the other hand, organic scintillators have low density which limits their applications in gamma spectroscopy. Due to high quantum

  10. A mechanism for supercooling in organic liquids

    SciTech Connect

    Thoma, P.E.

    1996-12-31

    In this investigation, a mechanism for supercooling inorganic liquids is formulated. By comparing the melting temperature and spontaneous freezing temperature of the chemicals evaluated with their molecular characteristics, the factors promoting supercooling are developed. The results obtained indicate that the following molecular characteristics promote supercooling in organic liquids: an unequal sharing of electrons between the atoms of a molecule; a three-dimensional chemical structure; a permanent, three-dimensional, and partially charged pocket within the chemical structure; a partially charged projection having a charge opposite that of the pocket and located on the side of the molecule opposite that of the pocket.

  11. Synthesis of scintillating metal organic frameworks for the detection of radiation from subatomic particles

    NASA Astrophysics Data System (ADS)

    Ingram, Conrad; Williams, Michael

    2013-04-01

    The objective of this research is to develop fluorescent metal organic frameworks (MOFs) as scintillation materials for more efficient light output and detection of ionizing radiation, such as neutrons, alpha particles or gamma rays, generated by fissile materials. MOFs are multidimensional porous structures, which are synthesized from the covalent bonding of metal ions or metal oxide clusters with organic ligand linkers, such as benzene dicarboxylates. The ligands will be chosen to have fluorescent characteristics, when excited by radiation or energetic sub-atomic particles. We will explore the synthesis of new MOFs, containing carboxylate ligands with unique conjugated chromophores, such as, benzene-1,3,5-triyltris(ethene-2,1-diyl)) tribenzoic acid and 9-hydroxy-9-vinyl-9H-fluorene-2,7-dicarboxylic acid), and doped with heavy metal as triplet-state harvesters, that we are proposing will result in stronger and possibly, unique luminescence spectral features that will allow for the discrimination between different ionizing radiations from subatomic particles. Photo-, catho- and radio-luminescence studies will be conducted on the materials, and radiation mechanism(s) will be investigated.

  12. Radiolabeling and Quantification of Cellular Levels of Phosphoinositides by High Performance Liquid Chromatography-coupled Flow Scintillation.

    PubMed

    Ho, Cheuk Y; Choy, Christopher H; Botelho, Roberto J

    2016-01-01

    Phosphoinositides (PtdInsPs) are essential signaling lipids responsible for recruiting specific effectors and conferring organelles with molecular identity and function. Each of the seven PtdInsPs varies in their distribution and abundance, which are tightly regulated by specific kinases and phosphatases. The abundance of PtdInsPs can change abruptly in response to various signaling events or disturbance of the regulatory machinery. To understand how these events lead to changes in the amount of PtdInsPs and their resulting impact, it is important to quantify PtdInsP levels before and after a signaling event or between control and abnormal conditions. However, due to their low abundance and similarity, quantifying the relative amounts of each PtdInsP can be challenging. This article describes a method for quantifying PtdInsP levels by metabolically labeling cells with (3)H-myo-inositol, which is incorporated into PtdInsPs. Phospholipids are then precipitated and deacylated. The resulting soluble (3)H-glycero-inositides are further extracted, separated by high-performance liquid chromatography (HPLC), and detected by flow scintillation. The labeling and processing of yeast samples is described in detail, as well as the instrumental setup for the HPLC and flow scintillator. Despite losing structural information regarding acyl chain content, this method is sensitive and can be optimized to concurrently quantify all seven PtdInsPs in cells. PMID:26780479

  13. Activity standardisation of ²²⁶Ra by 4πα liquid scintillation counting method.

    PubMed

    Havelka, Miroslav; Bluďovský, Richard

    2013-11-01

    Activity of (226)Ra in radium daughter products free solution was determined by 4πα liquid scintillation counting (LSC) method, where the detection efficiency of radium decay is practically equal to 1. The sources were prepared from solution with known (226)Ra mass concentration, from which, immediately before LS counting, (222)Rn and its daughter nuclides were removed by solvent extraction. LS counting results were corrected practically only for a <0.6% loss of radium from measured sample and for the ingrowth of (222)Rn and (218)Po concentrations in the sample after the separation was completed. The combined relative standard uncertainty was estimated to be lower than 0.34%. PMID:23602705

  14. Attenuation length measurements of a liquid scintillator with LabVIEW and reliability evaluation of the device

    NASA Astrophysics Data System (ADS)

    Gao, Long; Yu, Bo-Xiang; Ding, Ya-Yun; Zhou, Li; Wen, Liang-Jian; Xie, Yu-Guang; Wang, Zhi-Gang; Cai, Xiao; Sun, Xi-Lei; Fang, Jian; Xue, Zhen; Zhang, Ai-Wu; Lü, Qi-Wen; Sun, Li-Jun; Ge, Yong-Shuai; Liu, Ying-Biao; Niu, Shun-Li; Hu, Tao; Cao, Jun; Lü, Jun-Guang

    2013-07-01

    An attenuation length measurement device was constructed using an oscilloscope and LabVIEW for signal acquisition and processing. The performance of the device has been tested in a variety of ways. The test results show that the set-up has a good stability and high precision (sigma/mean reached 0.4 percent). Besides, the accuracy of the measurement system will decrease by about 17 percent if a filter is used. The attenuation length of a gadolinium-loaded liquid scintillator (Gd-LS) was measured as 15.10±0.35 m where Gd-LS was heavily used in the Daya Bay Neutrino Experiment. In addition, one method based on the Beer-Lambert law was proposed to investigate the reliability of the measurement device, the R-square reached 0.9995. Moreover, three purification methods for Linear Alkyl Benzene (LAB) production were compared in the experiment.

  15. A simple method to determine bioethanol content in gasoline using two-step extraction and liquid scintillation counting.

    PubMed

    Yunoki, Shunji; Saito, Masaaki

    2009-12-01

    A simple method for determining bioethanol content in gasoline containing bioethanol (denoted as E-gasoline in this study) is urgently required. Liquid scintillation counting (LSC) was employed based on the principle that (14)C exists in bioethanol but not in synthetic ethanol. Bioethanol was extracted in two steps by water from E-gasoline containing 3% (E3) or 10% (E10) bioethanol. The (14)C radioactivity was measured by LSC and converted to the amount of bioethanol. The bioethanol content in E-gasoline was determined precisely from the partition coefficient in the extraction and the amount of bioethanol in the water phases: 2.98+/-0.10% for E3 and 10.0+/-0.1% for E10 (means+/-SD; n=3). It appears that this method can be used to determine bioethanol content in E-gasoline quickly and easily. PMID:19577920

  16. Relative light yield and temporal response of a stilbene-doped bibenzyl organic scintillator for neutron detection

    SciTech Connect

    Brown, J. A.; Goldblum, B. L. Brickner, N. M.; Daub, B. H.; Kaufman, G. S.; Bibber, K. van; Vujic, J.; Bernstein, L. A.; Bleuel, D. L.; Caggiano, J. A.; Hatarik, R.; Phillips, T. W.; Zaitseva, N. P.; Wender, S. A.

    2014-05-21

    The neutron time-of-flight (nTOF) diagnostics used to characterize implosions at the National Ignition Facility (NIF) has necessitated the development of novel scintillators that exhibit a rapid temporal response and high light yield. One such material, a bibenzyl-stilbene mixed single-crystal organic scintillator grown in a 99.5:0.5 ratio in solution, has become the standard scintillator used for nTOF diagnostics at NIF. The prompt fluorescence lifetime and relative light yield as a function of proton energy were determined to calibrate this material as a neutron detector. The temporal evolution of the intensity of the prompt fluorescent response was modeled using first-order reaction kinetics and the prompt fluorescence decay constant was determined to be 2.46 ± 0.01 (fit) ± 0.13 (systematic) ns. The relative response of the bibenzyl-stilbene mixed crystal generated by recoiling protons was measured, and results were analyzed using Birks' relation to quantify the non-radiative quenching of excitation energy in the scintillator.

  17. Relative light yield and temporal response of a stilbene-doped bibenzyl organic scintillator for neutron detection

    NASA Astrophysics Data System (ADS)

    Brown, J. A.; Goldblum, B. L.; Bernstein, L. A.; Bleuel, D. L.; Brickner, N. M.; Caggiano, J. A.; Daub, B. H.; Kaufman, G. S.; Hatarik, R.; Phillips, T. W.; Wender, S. A.; van Bibber, K.; Vujic, J.; Zaitseva, N. P.

    2014-05-01

    The neutron time-of-flight (nTOF) diagnostics used to characterize implosions at the National Ignition Facility (NIF) has necessitated the development of novel scintillators that exhibit a rapid temporal response and high light yield. One such material, a bibenzyl-stilbene mixed single-crystal organic scintillator grown in a 99.5:0.5 ratio in solution, has become the standard scintillator used for nTOF diagnostics at NIF. The prompt fluorescence lifetime and relative light yield as a function of proton energy were determined to calibrate this material as a neutron detector. The temporal evolution of the intensity of the prompt fluorescent response was modeled using first-order reaction kinetics and the prompt fluorescence decay constant was determined to be 2.46 ± 0.01 (fit) ± 0.13 (systematic) ns. The relative response of the bibenzyl-stilbene mixed crystal generated by recoiling protons was measured, and results were analyzed using Birks' relation to quantify the non-radiative quenching of excitation energy in the scintillator.

  18. Warhead verification as inverse problem: Applications of neutron spectrum unfolding from organic-scintillator measurements

    NASA Astrophysics Data System (ADS)

    Lawrence, Chris C.; Febbraro, Michael; Flaska, Marek; Pozzi, Sara A.; Becchetti, F. D.

    2016-08-01

    Verification of future warhead-dismantlement treaties will require detection of certain warhead attributes without the disclosure of sensitive design information, and this presents an unusual measurement challenge. Neutron spectroscopy—commonly eschewed as an ill-posed inverse problem—may hold special advantages for warhead verification by virtue of its insensitivity to certain neutron-source parameters like plutonium isotopics. In this article, we investigate the usefulness of unfolded neutron spectra obtained from organic-scintillator data for verifying a particular treaty-relevant warhead attribute: the presence of high-explosive and neutron-reflecting materials. Toward this end, several improvements on current unfolding capabilities are demonstrated: deuterated detectors are shown to have superior response-matrix condition to that of standard hydrogen-base scintintillators; a novel data-discretization scheme is proposed which removes important detector nonlinearities; and a technique is described for re-parameterizing the unfolding problem in order to constrain the parameter space of solutions sought, sidestepping the inverse problem altogether. These improvements are demonstrated with trial measurements and verified using accelerator-based time-of-flight calculation of reference spectra. Then, a demonstration is presented in which the elemental compositions of low-Z neutron-attenuating materials are estimated to within 10%. These techniques could have direct application in verifying the presence of high-explosive materials in a neutron-emitting test item, as well as other for treaty verification challenges.

  19. Solidification of oils and organic liquids

    SciTech Connect

    Clark, D.E.; Colombo, P.; Neilson, R.M. Jr.

    1982-07-01

    The suitability of selected solidification media for application in the disposal of low-level oil and other organic liquid wastes has been investigated. In the past, these low-level wastes (LLWs) have commonly been immobilized by sorption onto solid absorbents such as vermiculite or diatomaceous earth. Evolving regulations regarding the disposal of these materials encourage solidification. Solidification media which were studied include Portland type I cement; vermiculite plus Portland type I cement; Nuclear Technology Corporation's Nutek 380-cement process; emulsifier, Portland type I cement-sodium silicate; Delaware Custom Materiel's cement process; and the US Gypsum Company's Envirostone process. Waste forms have been evaluated as to their ability to reliably produce free standing monolithic solids which are homogeneous (macroscopically), contain < 1% free standing liquids by volume and pass a water immersion test. Solidified waste form specimens were also subjected to vibratory shock testing and flame testing. Simulated oil wastes can be solidified to acceptable solid specimens having volumetric waste loadings of less than 40 volume-%. However, simulated organic liquid wastes could not be solidified into acceptable waste forms above a volumetric loading factor of about 10 volume-% using the solidification agents studied.

  20. Fiber-coupled organic plastic scintillator for on-line dose rate monitoring in 6 MV X-ray beam for external radiotherapy

    NASA Astrophysics Data System (ADS)

    Lindvold, Lars R.; Beierholm, A. R.; Andersen, C. E.

    2010-02-01

    Fiber-coupled organic plastic scintillators enable on-line dose rate monitoring in conjunction with pulsed radiation sources like linear medical accelerators (linacs). The accelerator, however, generates a significant amount of stray ionizing radiation. This radiation excites the long optical fiber (15-20 m), connecting the scintillator, typically with a diameter of 1 mm and 5 mm in length, with the optical detector circuit, causing parasitic luminescence in the optical fiber. In this paper we propose a method for circumventing this problem. The method is based on the use of an organic scintillator, 2-Naphthoic acid, doped in an optical polymer. The organic scintillator possesses a long luminescent lifetime (room temperature phosphorescence). The scintillator is molded onto the distal end of a polymer optical fiber. The luminescent signal from the scintillator is detected by a PMT in photon-counting mode. The long lifetime of the scintillator signal facilitates a temporal gating of the dose rate signal with respect to the parasitic luminescence from the optical fiber. We will present data obtained using a solid water phantom irradiated with 6 MV Xrays from a medical linac at the Copenhagen University Hospital. Also issues pertaining to the selection of proper matrix as well as phosphorescent dye will be presented in this paper.

  1. Comparison of calculated spectra for the interaction of photons in a liquid scintillator. Example of 54Mn 835 keV emission.

    PubMed

    Cassette, P; Ahn, G H; Alzitzoglou, T; Aubineau-Lanièce, I; Bochud, F; Garcia Torano, E; Grau Carles, A; Grau Malonda, A; Kossert, K; Lee, K B; Laedermann, J P; Simpson, B R S; van Wyngaardt, W M; Zimmerman, B E

    2006-01-01

    The CIEMAT/NIST and TDCR methods in liquid scintillation counting, initially developed for the activity standardization of pure-beta radionuclides, have been extended to the standardization of electron capture and beta-gamma radionuclides. Both methods require the calculation of the energy spectrum absorbed by the liquid scintillator. For radionuclides emitting X-rays or gamma-rays, when the energy is greater than a few tens of keV the Compton interaction is important and the absorption is not total. In this case, the spectrum absorbed by the scintillator must be calculated using analytical or stochastic models. An illustration of this problem is the standardization of 54Mn, which is a radionuclide decaying by electron capture. The gamma transition, very weakly converted, leads to the emission of an 835 keV photon. The calculation of the detection efficiency of this radionuclide requires the calculation of the energy spectrum transferred to the scintillator after the absorption of the gamma ray and the associated probability of absorption. The validity of the method is thus dependent on the correct calculation of the energy transferred to the scintillator. In order to compare the calculation results obtained using various calculation tools, and to provide the metrology community with some information on the choice of these tools, the LS working group of the ICRM organised a comparison of the calculated absorbed spectra for the 835 keV photon of 54Mn. The result is the spectrum of the energy absorbed by the scintillator per emission of an 835 keV gamma ray. This exercise was proposed for a standard 20 ml LS glass vial and for LS cocktail volumes of 10 and 15 ml. The calculation was done for two different cocktails: toluene and a widely used commercial cocktail, Ultima Gold. The paper describes the results obtained by nine participants using a total of 12 calculation codes. PMID:16600600

  2. The SNO+ Scintillator Purification Plant and Projected Sensitivity to Solar Neutrinos in the Pure Scintillator Phase

    NASA Astrophysics Data System (ADS)

    Pershing, Teal; SNO+ Collaboration

    2016-03-01

    The SNO+ detector is a neutrino and neutrinoless double-beta decay experiment utilizing the renovated SNO detector. In the second phase of operation, the SNO+ detector will contain 780 tons of organic liquid scintillator composed of 2 g/L 2,5-diphenyloxazole (PPO) in linear alkylbenzene (LAB). In this phase, SNO+ will strive to detect solar neutrinos in the sub-MeV range, including CNO production neutrinos and pp production neutrinos. To achieve the necessary detector sensitivity, a four-part scintillator purification plant has been constructed in SNOLAB for the removal of ionic and radioactive impurities. We present an overview of the SNO+ scintillator purification plant stages, including distillation, water extraction, gas stripping, and metal scavenger columns. We also give the projected SNO+ sensitivities to various solar-produced neutrinos based on the scintillator plant's projected purification efficiency.

  3. Integrated readout of organic scintillator and ZnS:Ag/6LiF for segmented antineutrino detectors.

    SciTech Connect

    Kiff, Scott D.; Reyna, David; Monahan, James; Bowden, Nathaniel S.

    2010-11-01

    Antineutrino detection using inverse beta decay conversion has demonstrated the capability to measure nuclear reactor power and fissile material content for nuclear safeguards. Current efforts focus on aboveground deployment scenarios, for which highly efficient capture and identification of neutrons is needed to measure the anticipated antineutrino event rates in an elevated background environment. In this submission, we report on initial characterization of a new scintillation-based segmented design that uses layers of ZnS:Ag/{sup 6}LiF and an integrated readout technique to capture and identify neutrons created in the inverse beta decay reaction. Laboratory studies with multiple organic scintillator and ZnS:Ag/{sup 6}LiF configurations reliably identify {sup 6}Li neutron captures in 60 cm-long segments using pulse shape discrimination.

  4. Verification of proton range, position, and intensity in IMPT with a 3D liquid scintillator detector system

    PubMed Central

    Archambault, L.; Poenisch, F.; Sahoo, N.; Robertson, D.; Lee, A.; Gillin, M. T.; Mohan, R.; Beddar, S.

    2012-01-01

    Purpose: Intensity-modulated proton therapy (IMPT) using spot scanned proton beams relies on the delivery of a large number of beamlets to shape the dose distribution in a highly conformal manner. The authors have developed a 3D system based on liquid scintillator to measure the spatial location, intensity, and depth of penetration (energy) of the proton beamlets in near real-time. Methods: The detector system consists of a 20 × 20 × 20 cc liquid scintillator (LS) material in a light tight enclosure connected to a CCD camera. This camera has a field of view of 25.7 by 19.3 cm and a pixel size of 0.4 mm. While the LS is irradiated, the camera continuously acquires images of the light distribution produced inside the LS. Irradiations were made with proton pencil beams produced with a spot-scanning nozzle. Pencil beams with nominal ranges in water between 9.5 and 17.6 cm were scanned to irradiate an area of 10 × 10 cm square on the surface of the LS phantom. Image frames were acquired at 50 ms per frame. Results: The signal to noise ratio of a typical Bragg peak was about 170. Proton range measured from the light distribution produced in the LS was accurate to within 0.3 mm on average. The largest deviation seen between the nominal and measured range was 0.6 mm. Lateral position of the measured pencil beam was accurate to within 0.4 mm on average. The largest deviation seen between the nominal and measured lateral position was 0.8 mm; however, the accuracy of this measurement could be improved by correcting light scattering artifacts. Intensity of single proton spots were measured with precision ranging from 3 % for the smallest spot intensity (0.005 MU) to 0.5 % for the largest spot (0.04 MU). Conclusions: Our LS detector system has been shown to be capable of fast, submillimeter spatial localization of proton spots delivered in a 3D volume. This system could be used for beam range, intensity and position verification in IMPT. PMID:22380355

  5. Verification of proton range, position, and intensity in IMPT with a 3D liquid scintillator detector system

    SciTech Connect

    Archambault, L.; Poenisch, F.; Sahoo, N.; Robertson, D.; Lee, A.; Gillin, M. T.; Mohan, R.; Beddar, S.

    2012-03-15

    Purpose: Intensity-modulated proton therapy (IMPT) using spot scanned proton beams relies on the delivery of a large number of beamlets to shape the dose distribution in a highly conformal manner. The authors have developed a 3D system based on liquid scintillator to measure the spatial location, intensity, and depth of penetration (energy) of the proton beamlets in near real-time. Methods: The detector system consists of a 20 x 20 x 20 cc liquid scintillator (LS) material in a light tight enclosure connected to a CCD camera. This camera has a field of view of 25.7 by 19.3 cm and a pixel size of 0.4 mm. While the LS is irradiated, the camera continuously acquires images of the light distribution produced inside the LS. Irradiations were made with proton pencil beams produced with a spot-scanning nozzle. Pencil beams with nominal ranges in water between 9.5 and 17.6 cm were scanned to irradiate an area of 10 x 10 cm square on the surface of the LS phantom. Image frames were acquired at 50 ms per frame. Results: The signal to noise ratio of a typical Bragg peak was about 170. Proton range measured from the light distribution produced in the LS was accurate to within 0.3 mm on average. The largest deviation seen between the nominal and measured range was 0.6 mm. Lateral position of the measured pencil beam was accurate to within 0.4 mm on average. The largest deviation seen between the nominal and measured lateral position was 0.8 mm; however, the accuracy of this measurement could be improved by correcting light scattering artifacts. Intensity of single proton spots were measured with precision ranging from 3 % for the smallest spot intensity (0.005 MU) to 0.5 % for the largest spot (0.04 MU). Conclusions: Our LS detector system has been shown to be capable of fast, submillimeter spatial localization of proton spots delivered in a 3D volume. This system could be used for beam range, intensity and position verification in IMPT.

  6. Decoloration and solubilization of plant tissue prior to determination of /sup 3/H, /sup 14/C, and /sup 35/S by liquid scintillation

    SciTech Connect

    Smith, I.K.; Lang, A.L.

    1987-08-01

    A method is described for the decoloration and partial solubilization of plant tissue with 2% sodium hypochlorite. Following treatment of the digest with ammonia, the samples are suitable for the determination of /sup 3/H, /sup 14/C, and /sup 35/S by liquid scintillation counting. The color quenching is negligible and counting efficiencies are high: 30-40% for /sup 3/H and 90-95% for /sup 14/C.

  7. Method and apparatus for destroying organic contaminants in aqueous liquids

    DOEpatents

    Donaldson, T.L.; Wilson, J.H.

    1993-09-21

    A method and apparatus for destroying organic contaminants, such as trichloroethylene, in aqueous liquids, such as groundwater, utilizing steam stripping integrated with biodegradation. The contaminated aqueous liquid is fed into a steam stripper causing the volatilization of essentially all of the organic contaminants and a portion of the aqueous liquid. The majority of the aqueous liquid is discharged from the steam stripper. The volatilized vapors are then condensed to the liquid phase and introduced into a bioreactor. The bioreactor contains methanotrophic microorganisms which convert the organic contaminants into mainly carbon dioxide. The effluent from the bioreactor is then recycled back to the steam stripper for further processing. 2 figures.

  8. Method and apparatus for destroying organic contaminants in aqueous liquids

    DOEpatents

    Donaldson, Terrence L.; Wilson, James H.

    1993-01-01

    A method and apparatus for destroying organic contaminants, such as trichloroethylene, in aqueous liquids, such as groundwater, utilizing steam stripping integrated with biodegradation. The contaminated aqueous liquid is fed into a steam stripper causing the volatilization of essentially all of the organic contaminants and a portion of the aqueous liquid. The majority of the aqueous liquid is discharged from the steam stripper. The volatilized vapors are then condensed to the liquid phase and introduced into a bioreactor. The bioreactor contains methanotrophic microorganisms which convert the organic contaminants into mainly carbon dioxide. The effluent from the bioreactor is then recycled back to the steam stripper for further processing.

  9. Visualization of residual organic liquid trapped in aquifers

    SciTech Connect

    Conrad, S.H.; Wilson, J.L.; Mason, W.R.; Peplinski, W.J. )

    1992-02-01

    Organic liquids that are essentially immiscible with water migrate through the subsurface under the influence of capillary, viscous, and buoyancy forces. These liquids originate from the improper disposal of hazardous wastes, and the spills and leaks of petroleum hydrocarbons and solvents. The flow visualization experiments described in this study examined the migration of organic liquids through the saturated zone of aquifers, with a primary focus on the behavior of the residual organic liquid saturation, referring to that portion of the organic liquid that is trapped by capillary forces. Etched glass micromodels were used to visually observe dynamic multiphase displacement processes in pore networks. The resulting fluid distributions were photographed. Pore and blob casts were produced by a technique in which an organic liquid was solidified in place within a sand column at the conclusion of a displacement. The columns were sectioned and examined under optical and scanning electron microscopes. Photomicrographs of these sections show the morphology of the organic phase and its location within the sand matrix. The photographs from both experimental techniques reveal that in the saturated zone large amounts of residual organic liquid are trapped as isolated blobs of microscopic size. The size, shape, and spatial distribution of these blobs of residual organic liquid affect the dissolution of organic liquid into the water phase and the biotransformation of organic components. These processes are of concern for the prediction of pollution migration and the design of aquifer remediation schemes.

  10. Determination of radiostrontium in milk samples by ultra-low-level liquid scintillation counting: a validated approach.

    PubMed

    dell'Oro, Daniela; Iammarino, Marco; Bortone, Nicola; Mangiacotti, Michele; Chiaravalle, Antonio Eugenio

    2014-01-01

    Strontium-90 is a hazardous radionuclide derived from nuclear fission processes, and it decays emitting high-energy beta-particles forming yttrium-90. It may be easily absorbed in humans through several food supply chains, since it is chemically similar to some important biological elements such as potassium and calcium. In this work an analytical method for the determination of radiostrontium in milk by liquid scintillation counting was developed in order to obtain a precise quantification at low activity concentration levels. Moreover, a full validative approach was applied to confirm method reliability. Good analytical performance was obtained by developing an in-house validation model according to Regulation 882/2004/EC and Decision 657/2002/EC with a good selectivity, a decision threshold and detection limit corresponding to 0.003 and 0.006 Bq l⁻¹ (α = β = 0.05) respectively, a repeatability value, expressed as CV%, equal to 13%, a mean recovery value equal to 102.5% and a measurement uncertainty equal to 11.5%. Strontium and yttrium chemical yields were determined by a reliable analytical method by inductively coupled mass spectrometry, assuring a suitable correction of final result. The results of the method validation, combined with a quality control assurance, performed on a reference material, demonstrated that the procedure represents a substantial improvement in the determination of ⁹⁰Sr relating to accurate confirmation analyses. PMID:25299737

  11. Determination of (222)Rn absorption properties of polycarbonate foils by liquid scintillation counting. Application to (222)Rn measurements.

    PubMed

    Mitev, K; Cassette, P; Georgiev, S; Dimitrova, I; Sabot, B; Boshkova, T; Tartès, I; Pressyanov, D

    2016-03-01

    This work demonstrates that a Liquid Scintillation Counting (LSC) technique using a Triple to Double Coincidence Ratio counter with extending dead-time is very appropriate for the accurate measurement of (222)Rn activity absorbed in thin polycarbonate foils. It is demonstrated that using a toluene-based LS cocktail, which dissolves polycarbonates, the (222)Rn activity absorbed in thin Makrofol N foil can be determined with a relative standard uncertainty of about 0.7%. A LSC-based application of the methodology for determination of the diffusion length of (222)Rn in thin polycarbonate foils is proposed and the diffusion length of (222)Rn in Makrofol N (38.9±1.3µm) and the partition coefficient of (222)Rn in Makrofol N from air (112±12, at 20°C) and from water (272±17, at 21°C) are determined. Calibration of commercial LS spectrometers for (222)Rn measurements by LSC of thin polycarbonate foils is performed and the minimum detectable activities by this technique are estimated. PMID:26640234

  12. A high-sensitivity method for the measurement of 222Rn based on liquid scintillation counting of polycarbonate powder.

    PubMed

    Mitev, K; Georgiev, S; Pressyanov, D; Dimitrova, I; Zhivkova, V; Boshkova, T

    2014-07-01

    This work describes a technique for the measurement of 222Rn by absorption in polycarbonate (PC) powder and liquid scintillation counting (LSC). The work is an improvement of the recently proposed method for 222Rn measurements by LSC of exposed PC grains. It is demonstrated that the use of PC powder as a 222Rn sampler improves 13.6 times the sampling efficiency and leads to 6.5 times smaller minimmal detectable activity concentrations (MDAC) compared with the PC grains used so far. For a 40-h exposure of 7.4-g PC powder to 222Rn in air, the MDAC with a RackBeta 1219 LS counter is 62 Bq m(-3) (assuming a 8-h sample counting time and 24-h background time). For the same conditions the estimated 222Rn MDAC with a Quantulus 1220 LS counter is 20 Bq m(-3). The proposed technique is suitable for radon in air and radon in soil-gas measurements. PMID:24723190

  13. Investigation of the organic matter in inactive nuclear tank liquids

    SciTech Connect

    Schenley, R.L.; Griest, W.H.

    1990-08-01

    Environmental Protection Agency (EPA) methodology for regulatory organics fails to account for the organic matter that is suggested by total organic carbon (TOC) analysis in the Oak Ridge National Laboratory (ORNL) inactive nuclear waste-tank liquids and sludges. Identification and measurement of the total organics are needed to select appropriate waste treatment technologies. An initial investigation was made of the nature of the organics in several waste-tank liquids. This report details the analysis of ORNL wastes.

  14. A plastic scintillation counter prototype.

    PubMed

    Furuta, Etsuko; Kawano, Takao

    2015-10-01

    A new prototype device for beta-ray measurement, a plastic scintillation counter, was assembled as an alternative device to liquid scintillation counters. This device uses plastic scintillation sheets (PS sheets) as a sample applicator without the use of a liquid scintillator. The performance was evaluated using tritium labeled compounds, and good linearity was observed between the activity and net count rate. The calculated detection limit of the device was 0.01 Bq mL(-1) after 10 h measurement for 2 mL sample. PMID:26164628

  15. Separation and Purification and Beta Liquid Scintillation Analysis of Sm-151 in Savannah River Site and Hanford Site DOE High Level Waste

    SciTech Connect

    Dewberry, R.A.

    2001-02-13

    This paper describes development work to obtain a product phase of Sm-151 pure of any other radioactive species so that it can be determined in US Department of Energy high level liquid waste and low level solid waste by liquid scintillation {beta}-spectroscopy. The technique provides separation from {mu}Ci/ml levels of Cs-137, Pu alpha and Pu-241 {beta}-decay activity, and Sr-90/Y-90 activity. The separation technique is also demonstrated to be useful for the determination of Pm-147.

  16. An algorithm for charge-integration, pulse-shape discrimination and estimation of neutron/photon misclassification in organic scintillators

    NASA Astrophysics Data System (ADS)

    Polack, J. K.; Flaska, M.; Enqvist, A.; Sosa, C. S.; Lawrence, C. C.; Pozzi, S. A.

    2015-09-01

    Organic scintillators are frequently used for measurements that require sensitivity to both photons and fast neutrons because of their pulse shape discrimination capabilities. In these measurement scenarios, particle identification is commonly handled using the charge-integration pulse shape discrimination method. This method works particularly well for high-energy depositions, but is prone to misclassification for relatively low-energy depositions. A novel algorithm has been developed for automatically performing charge-integration pulse shape discrimination in a consistent and repeatable manner. The algorithm is able to estimate the photon and neutron misclassification corresponding to the calculated discrimination parameters, and is capable of doing so using only the information measured by a single organic scintillator. This paper describes the algorithm and assesses its performance by comparing algorithm-estimated misclassification to values computed via a more traditional time-of-flight estimation. A single data set was processed using four different low-energy thresholds: 40, 60, 90, and 120 keVee. Overall, the results compared well between the two methods; in most cases, the algorithm-estimated values fell within the uncertainties of the TOF-estimated values.

  17. Cryogenic THGEM-GPM for the readout of scintillation light from liquid argon

    NASA Astrophysics Data System (ADS)

    Xie, Wenqing; Fu, Yidong; Li, Yulan; Li, Jin; Li, Yuanjing; Yue, Qian

    2015-02-01

    A GPM (Gaseous Photo Multiplier) based on GEMs (Gas Electron Multipliers) and THGEMs (Thick Gas Electron Multipliers) is a promising detector for VUV (Vacuum Ultra Violet) photon readouts in rare event experiments which use cryogenic two-phase detectors with detection media of Ar and Xe. A GPM based on THGEM made of PTFE (herein named PTFE-THGEM) was developed inspired by the wide use of PTFE (polytetrafluoroethene) boards as low radioactive background PCB in rare event experiments. The efficiencies of the THGEM, a CsI photocathode, and finally a GPM are presented here. At low temperature (113 K) and 1.1 atm, the quantum efficiency of the GPM for VUV photons from liquid Ar in a two-phase detector is estimated to be 8.1% and the low threshold of the detector system for initial electrons prior to multiplication is 12 using 5 N purity Ar (0.99999).

  18. Synthesis of plastic scintillation microspheres: Evaluation of scintillators

    NASA Astrophysics Data System (ADS)

    Santiago, L. M.; Bagán, H.; Tarancón, A.; Garcia, J. F.

    2013-01-01

    The use of plastic scintillation microspheres (PSm) appear to be an alternative to liquid scintillation for the quantification of alpha and beta emitters because it does not generate mixed wastes after the measurement (organic and radioactive). In addition to routine radionuclide determinations, PSm can be used for further applications, e.g. for usage in a continuous monitoring equipment, for measurements of samples with a high salt concentration and for an extractive scintillation support which permits the separation, pre-concentration and measurement of the radionuclides without additional steps of elution and sample preparation. However, only a few manufacturers provide PSm, and the low number of regular suppliers reduces its availability and restricts the compositions and sizes available. In this article, a synthesis method based on the extraction/evaporation methodology has been developed and successfully used for the synthesis of plastic scintillation microspheres. Seven different compositions of plastic scintillation microspheres have been synthesised; PSm1 with polystyrene, PSm2 with 2,5-Diphenyloxazol(PPO), PSm3 with p-terphenyl (pT), PSm4 with PPO and 1,4-bis(5-phenyloxazol-2-yl) (POPOP), PSm5 pT and (1,4-bis [2-methylstyryl] benzene) (Bis-MSB), PSm6 with PPO, POPOP and naphthalene and PSm7 with pT, Bis-MSB and naphthalene. The synthesised plastic scintillation microspheres have been characterised in terms of their morphology, detection capabilities and alpha/beta separation capacity. The microspheres had a median diameter of approximately 130 μm. Maximum detection efficiency values were obtained for the PSm4 composition as follows 1.18% for 3H, 51.2% for 14C, 180.6% for 90Sr/90Y and 76.7% for 241Am. Values of the SQP(E) parameter were approximately 790 for PSm4 and PSm5. These values show that the synthesised PSm exhibit good scintillation properties and that the spectra are at channel numbers higher than in commercial PSm. Finally, the addition of

  19. Method for removing organic liquids from aqueous solutions and mixtures

    DOEpatents

    Hrubesh, Lawrence W.; Coronado, Paul R.; Dow, Jerome P.

    2004-03-23

    A method for removing organic liquids from aqueous solutions and mixtures. The method employs any porous material preferably in granular form and having small pores and a large specific surface area, that is hydrophobic so that liquid water does not readily wet its surface. In this method, organics, especially organic solvents that mix with and are more volatile than water, are separated from aqueous solution by preferentially evaporating across the liquid/solid boundary formed at the surfaces of the hydrophobic porous materials. Also, organic solvents that are immiscible with water, preferentially wet the surfaces of the hydrophobic material and are drawn within the porous materials by capillary action.

  20. Liquid crystal-templated conducting organic polymers

    DOEpatents

    Stupp, Samuel I.; Hulvat, James F.

    2004-01-20

    A method of preparing a conductive polymeric film, includes providing a liquid crystal phase comprising a plurality of hydrophobic cores, the phase on a substrate, introducing a hydrophobic component to the phase, the component a conductive polymer precursor, and applying an electric potential across the liquid crystal phase, the potential sufficient to polymerize the said precursor.

  1. Sensitivity and uncertainty analysis of the simulation of 123I and 54Mn gamma and X-ray emissions in a liquid scintillation vial.

    PubMed

    Bignell, L J; Mo, L; Alexiev, D; Hashemi-Nezhad, S R

    2010-01-01

    Radiation transport simulations of the most probable gamma- and X-ray emissions of (123)I and (54)Mn in a three photomultiplier tube liquid scintillation detector have been carried out. A Geant4 simulation was used to acquire energy deposition spectra and interaction probabilities with the scintillant, as required for absolute activity measurement using the triple to double coincidence ratio (TDCR) method. A sensitivity and uncertainty analysis of the simulation model is presented here. The uncertainty in the Monte Carlo simulation results due to the input parameter uncertainties was found to be more significant than the statistical uncertainty component for a typical number of simulated decay events. The model was most sensitive to changes in the volume of the scintillant. Estimates of the relative uncertainty associated with the simulation outputs due to the combined stochastic and input uncertainties are provided. A Monte Carlo uncertainty analysis of an (123)I TDCR measurement indicated that accounting for the simulation uncertainties increases the uncertainty of efficiency of the logical sum of double coincidence by 5.1%. PMID:20036571

  2. High-energy X-ray detection by hafnium-doped organic-inorganic hybrid scintillators prepared by sol-gel method

    SciTech Connect

    Sun, Yan; Koshimizu, Masanori Yahaba, Natsuna; Asai, Keisuke; Nishikido, Fumihiko; Kishimoto, Shunji; Haruki, Rie

    2014-04-28

    With the aim of enhancing the efficiency with which plastic scintillators detect high-energy X-rays, hafnium-doped organic-inorganic hybrid scintillators were fabricated via a sol-gel method. Transmission electron microscopy of sampled material reveals the presence of Hf{sub x}Si{sub 1−x}O{sub 2} nanoparticles, dispersed in a polymer matrix that constitutes the active material of the X-ray detector. With Hf{sub x}Si{sub 1−x}O{sub 2} nanoparticles incorporated in the polymer matrix, the absorption edge and the luminescence wavelength is shifted, which we attribute to Mie scattering. The detection efficiency for 67.4-keV X-rays in a 0.6-mm-thick piece of this material is two times better than the same thickness of a commercial plastic scintillator-NE142.

  3. Process for encapsulating radioactive organic liquids in a resin

    SciTech Connect

    Drake, S.S.; Filter, H.E.

    1983-05-03

    Radioactive organic liquids are converted to a form suitable for burial by the process wherein the liquid is contacted with insoluble, swellable polymer particles to form swollen gelled particles which are dispersed in an unsaturated polyester, vinyl ester resin or mixture thereof which is then cured to a solid state with the gelled particles encased therein.

  4. Ionization and Excitation in Non-Polar Organic Liquids.

    ERIC Educational Resources Information Center

    Lipsky, Sanford

    1981-01-01

    Reviews recent advances in radiation chemistry concerning the effect of high-energy radiation on organic liquids. Discusses the general nature of excited and ionized states, pathways for decay, the effect of environmental perturbation, the behavior of an electron in a nonpolar liquid, and comparison of photochemical and radiation chemical effects.…

  5. Process for recovering organic components from liquid streams

    DOEpatents

    Blume, Ingo; Baker, Richard W.

    1991-01-01

    A separation process for recovering organic components from liquid streams. The process is a combination of pervaporation and decantation. In cases where the liquid stream contains the organic to be separated in dissolved form, the pervaporation step is used to concentrate the organic to a point above the solubility limit, so that a two-phase permeate is formed and then decanted. In cases where the liquid stream is a two-phase mixture, the decantation step is performed first, to remove the organic product phase, and the residue from the decanter is then treated by pervaporation. The condensed permeate from the pervaporation unit is sufficiently concentrated in the organic component to be fed back to the decanter. The process can be tailored to produce only two streams: an essentially pure organic product stream suitable for reuse, and a residue stream for discharge or reuse.

  6. Scintillator material

    DOEpatents

    Anderson, David F.; Kross, Brian J.

    1994-01-01

    An improved scintillator material comprising cerium fluoride is disclosed. Cerium fluoride has been found to provide a balance of good stopping power, high light yield and short decay constant that is superior to known scintillator materials such as thallium-doped sodium iodide, barium fluoride and bismuth germanate. As a result, cerium fluoride is favorably suited for use as a scintillator material in positron emission tomography.

  7. Scintillator material

    DOEpatents

    Anderson, D.F.; Kross, B.J.

    1992-07-28

    An improved scintillator material comprising cerium fluoride is disclosed. Cerium fluoride has been found to provide a balance of good stopping power, high light yield and short decay constant that is superior to known scintillator materials such as thallium-doped sodium iodide, barium fluoride and bismuth germanate. As a result, cerium fluoride is favorably suited for use as a scintillator material in positron emission tomography. 4 figs.

  8. Scintillator material

    DOEpatents

    Anderson, D.F.; Kross, B.J.

    1994-06-07

    An improved scintillator material comprising cerium fluoride is disclosed. Cerium fluoride has been found to provide a balance of good stopping power, high light yield and short decay constant that is superior to known scintillator materials such as thallium-doped sodium iodide, barium fluoride and bismuth germanate. As a result, cerium fluoride is favorably suited for use as a scintillator material in positron emission tomography. 4 figs.

  9. Scintillator material

    DOEpatents

    Anderson, David F.; Kross, Brian J.

    1992-01-01

    An improved scintillator material comprising cerium fluoride is disclosed. Cerium fluoride has been found to provide a balance of good stopping power, high light yield and short decay constant that is superior to known scintillator materials such as thallium-doped sodium iodide, barium fluoride and bismuth germanate. As a result, cerium fluoride is favorably suited for use as a scintillator material in positron emission tomography.

  10. [Development of a simple quantitative method for the strontium-89 concentration of radioactive liquid waste using the plastic scintillation survey meter for beta rays].

    PubMed

    Narita, Hiroto; Tsuchiya, Yuusuke; Hirase, Kiyoshi; Uchiyama, Mayuki; Fukushi, Masahiro

    2012-11-01

    Strontium-89 (89Sr: pure beta, E; 1.495 MeV-100%, halflife: 50.5 days) chloride is used as pain relief from bone metastases. An assay of 89Sr is difficult because of a pure beta emitter. For management of 89Sr, we tried to evaluate a simple quantitative method for the 59Sr concentration of radioactive liquid waste using scintillation survey meter for beta rays. The counting efficiency of the survey meter with this method was 35.95%. A simple 30 minutes measurement of 2 ml of the sample made the quantitative measurement of 89Sr practical. Reducing self-absorption of the beta ray in the solution by counting on the polyethlene paper improved the counting efficiency. Our method made it easy to manage the radioactive liquid waste under the legal restrictions. PMID:23402205

  11. Real-time, digital pulse-shape discrimination in non-hazardous fast liquid scintillation detectors: Prospects for safety and security

    SciTech Connect

    Joyce, M. J.; Aspinall, M. D.; Cave, F. D.; Lavietes, A. D.

    2011-07-01

    Pulse-shape discrimination (PSD) in fast, organic scintillation detectors is a long-established technique used to separate neutrons and {gamma} rays in mixed radiation fields. In the analogue domain the method can achieve separation in real time, but all knowledge of the pulses themselves is lost thereby preventing the possibility of any post- or repeated analysis. Also, it is typically reliant on electronic systems that are largely obsolete and which require significant experience to set up. In the digital domain, PSD is often more flexible but significant post-processing has usually been necessary to obtain neutron/{gamma}-ray separation. Moreover, the scintillation media on which the technique relies usually have a low flash point and are thus deemed hazardous. This complicates the ease with which they are used in industrial applications. In this paper, results obtained with a new portable digital pulse-shape discrimination instrument are described. This instrument provides real-time, digital neutron/{gamma} separation whilst preserving the synchronization with the time-of-arrival for each event, and realizing throughputs of 3 x 10{sup 6} events per second. Furthermore, this system has been tested with a scintillation medium that is non-flammable and not hazardous. (authors)

  12. A Guided Inquiry Liquid/Liquid Extractions Laboratory for Introductory Organic Chemistry

    ERIC Educational Resources Information Center

    Raydo, Margaret L.; Church, Megan S.; Taylor, Zane W.; Taylor, Christopher E.; Danowitz, Amy M.

    2015-01-01

    A guided inquiry laboratory experiment for teaching liquid/liquid extractions to first semester undergraduate organic chemistry students is described. This laboratory is particularly useful for introductory students as the analytes that are separated are highly colored dye molecules. This allows students to track into which phase each analyte…

  13. Hierarchical Organization in Liquid Crystal-in-Liquid Crystal Emulsions

    PubMed Central

    Mushenheim, Peter C.

    2014-01-01

    We report the formation and characterization of hierarchical ordering in systems comprised of micrometer-sized droplets of thermotropic nematic liquid crystals (LCs) dispersed in continuous nematic phases of a lyotropic chromonic LC (disodium cromoglycate (DSCG)). Significantly, we find the orientations of the two LC phases to be coupled, with nematic droplets of 4′-pentyl-4-cyanobiphenyl (5CB) exhibiting a bipolar configuration with an axis of symmetry aligned orthogonal to the far-field director of the DSCG phase. We determine that this coupling of orientations does not result from either anisometric LC droplet shape or interfacial ionic phenomena but rather is consistent with the influence of van der Waals interactions that arise from the anisotropic polarizabilities of nematic 5CB (Δn = + 0.18) and DSCG (Δn = − 0.02) phases. We also find that it is possible to rotate and uniformly align the nematic droplets by using a weak magnetic field (B ∼ 0.3 T). An analysis of the dynamics of relaxation of the orientations of the 5CB droplets following removal of the magnetic field reveals the DSCG and 5CB droplets to be coupled by energies of ∼104kT, consistent with a simple theoretical estimate of the influence of anisotropic van der Waals interactions. We also observed the nematic 5CB droplets to form dimers and larger assemblies mediated by the elasticity of the nematic DSCG. Overall, these results reveal that LC-in-LC emulsions define a new class of hierarchically ordered soft matter in which both thermotropic and lyotropic LCs are coupled in their ordering. PMID:25278032

  14. Hierarchical organization in liquid crystal-in-liquid crystal emulsions.

    PubMed

    Mushenheim, Peter C; Abbott, Nicholas L

    2014-11-21

    We report the formation and characterization of hierarchical ordering in systems comprised of micrometer-sized droplets of thermotropic nematic liquid crystals (LCs) dispersed in continuous nematic phases of a lyotropic chromonic LC (disodium cromoglycate (DSCG)). Significantly, we find the orientations of the two LC phases to be coupled, with nematic droplets of 4'-pentyl-4-cyanobiphenyl (5CB) exhibiting a bipolar configuration with an axis of symmetry aligned orthogonal to the far-field director of the DSCG phase. We determine that this coupling of orientations does not result from either anisometric LC droplet shape or interfacial ionic phenomena but rather is consistent with the influence of van der Waals interactions that arise from the anisotropic polarizabilities of nematic 5CB (Δn = +0.18) and DSCG (Δn = -0.02) phases. We also find that it is possible to rotate and uniformly align the nematic droplets by using a weak magnetic field (B ∼ 0.3 T). An analysis of the dynamics of relaxation of the orientations of the 5CB droplets following removal of the magnetic field reveals the DSCG and 5CB droplets to be coupled by energies of ∼10(4) kT, consistent with a simple theoretical estimate of the influence of anisotropic van der Waals interactions. We also observed the nematic 5CB droplets to form dimers and larger assemblies mediated by the elasticity of the nematic DSCG. Overall, these results reveal that LC-in-LC emulsions define a new class of hierarchically ordered soft matter in which both thermotropic and lyotropic LCs are coupled in their ordering. PMID:25278032

  15. Determination of neutron-induced alpha-particle cross sections on carbon using the response of a liquid scintillation detector

    SciTech Connect

    Brede, H.J.; Dietze, G.; Klein, H.; Schoelermann, H. )

    1991-01-01

    This paper presents the sums of the cross section {sup 12}C(n, {alpha}{sub 0}) {sup 9}Be and {sup 12}C(n, N{prime}3{alpha}) determined in the neutron energy range between 7.4 and 11 MeV. An NE-213 scintillation detector is simultaneously used as a carbon target, an alpha-particle detector, and a neutron fluence monitor. By comparing the measured and calculated response spectra, the neutron-induced alpha-particle events in the scintillation volume are separated and the cross sections {sigma}{sub n,{alpha}0} + {sigma}{sub n,n{prime}3{alpha}} are determined relative to the n-p scattering cross section. The pulse-height distribution due to alpha particles allows the angular distribution to be extracted on the basis of the reaction kinematics and an accurately determined light output function for alpha particles in the NE-213 detector.

  16. Synergistic Assembly of Heavy Metal Clusters and Luminescent Organic Bridging Ligands in Metal–Organic Frameworks for Highly Efficient X-ray Scintillation

    PubMed Central

    2015-01-01

    We have designed two metal–organic frameworks (MOFs) to efficiently convert X-ray to visible-light luminescence. The MOFs are constructed from M6(μ3-O)4(μ3-OH)4(carboxylate)12 (M = Hf or Zr) secondary building units (SBUs) and anthracene-based dicarboxylate bridging ligands. The high atomic number of Zr and Hf in the SBUs serves as effective X-ray antenna by absorbing X-ray photons and converting them to fast electrons through the photoelectric effect. The generated electrons then excite multiple anthracene-based emitters in the MOF through inelastic scattering, leading to efficient generation of detectable photons in the visible spectrum. The MOF materials thus serve as efficient X-ray scintillators via synergistic X-ray absorption by the metal-cluster SBUs and optical emission by the bridging ligands. PMID:24730683

  17. Synergistic assembly of heavy metal clusters and luminescent organic bridging ligands in metal-organic frameworks for highly efficient X-ray scintillation.

    PubMed

    Wang, Cheng; Volotskova, Olga; Lu, Kuangda; Ahmad, Moiz; Sun, Conroy; Xing, Lei; Lin, Wenbin

    2014-04-30

    We have designed two metal-organic frameworks (MOFs) to efficiently convert X-ray to visible-light luminescence. The MOFs are constructed from M6(μ3-O)4(μ3-OH)4(carboxylate)12 (M = Hf or Zr) secondary building units (SBUs) and anthracene-based dicarboxylate bridging ligands. The high atomic number of Zr and Hf in the SBUs serves as effective X-ray antenna by absorbing X-ray photons and converting them to fast electrons through the photoelectric effect. The generated electrons then excite multiple anthracene-based emitters in the MOF through inelastic scattering, leading to efficient generation of detectable photons in the visible spectrum. The MOF materials thus serve as efficient X-ray scintillators via synergistic X-ray absorption by the metal-cluster SBUs and optical emission by the bridging ligands. PMID:24730683

  18. A new tritiated water measurement method with plastic scintillator pellets.

    PubMed

    Furuta, Etsuko; Iwasaki, Noriko; Kato, Yuka; Tomozoe, Yusuke

    2016-01-01

    A new tritiated water measurement method with plastic scintillator pellets (PS-pellets) by using a conventional liquid scintillation counter was developed. The PS-pellets used were 3 mm in both diameter and length. A low potassium glass vial was filled full with the pellets, and tritiated water was applied to the vial from 5 to 100 μl. Then, the sample solution was scattered in the interstices of the pellets in a vial. This method needs no liquid scintillator, so no liquid organic waste fluid is generated. The counting efficiency with the pellets was approximately 48 % when a 5 μl solution was used, which was higher than that of conventional measurement using liquid scintillator. The relationship between count rate and activity showed good linearity. The pellets were able to be used repeatedly, so few solid wastes are generated with this method. The PS-pellets are useful for tritiated water measurement; however, it is necessary to develop a new device which can be applied to a larger volume and measure low level concentration like an environmental application. PMID:26856930

  19. [Utilization of organic resources in paper pulp waste liquid].

    PubMed

    Lin, Qiaojia; Liu, Jinghong; Yang, Guidi; Huang, Biao

    2005-04-01

    In this paper, one hundred percent of condensed sulfate paper pulp waste liquid was used as the raw material of adhesive, and the activation of its lignin as well as the improving effects of phenol formaldehyde resin and polyfunctional aqueous polymer isocyanate (PAPI) were studied. The results showed that adding formaldehyde to the waste liquid could increase the reactivity of contained lignin, and adding 30% phenol formaldehyde resin or 20% PAPI could make the waste liquid in place of pure phenol formaldehyde resin for producing class I plywood. Furthermore, the cost could be reduced by 55.5% and 49.0%, respectively, in comparing with pure phenol formaldehyde resin. This approach fully used the organic resources in paper pulp waste liquid, reduced environment pollution at the same time, and had unexceptionable economic, social and ecological benefits. The feasibility of preparing adhesives from paper pulp waste liquid was also analyzed by infrared spectrum. PMID:16011170

  20. Scintillator Measurements for SNO+

    NASA Astrophysics Data System (ADS)

    Kaptanoglu, Tanner; SNO+ Collaboration

    2016-03-01

    SNO+ is a neutrino detector located 2km underground in the SNOLAB facility with the primary goal of searching for neutrinoless double beta decay. The detector will be filled with a liquid scintillator target primarily composed of linear alkyl benzene (LAB). As charged particles travel through the detector the LAB produces scintillation light which is detected by almost ten thousand PMTs. The LAB is loaded with Te130, an isotope known to undergo double beta decay. Additionally, the LAB is mixed with an additional fluor and wavelength shifter to improve the light output and shift the light to a wavelength regime in which the PMTs are maximally efficient. The precise scintillator optics drastically affect the ultimate sensitivity of SNO+. I will present work being done to measure the optical properties of the SNO+ scintillator cocktail. The measured properties are used as input to a scintillation model that allows us to extrapolate to the SNO+ scale and ultimately predict the sensitivity of the experiment. Additionally, I will present measurements done to characterize the R5912 PMT, a candidate PMT for the second phase of SNO+ that provides better light collection, improved charge resolution, and a narrower spread in timing.

  1. Dual Ionic and Organic Nature of Ionic Liquids.

    PubMed

    Shi, Rui; Wang, Yanting

    2016-01-01

    Inherited the advantages of inorganic salts and organic solvents, ionic liquids (ILs) exhibit many superior properties allowing them promising green solvents for the future. Although it has been widely acknowledged that the unique features of ILs originate from their dual ionic and organic nature, its microscopic physical origin still remains blurry. In this work, by comparing the ion/molecule cage structures obtained from molecular dynamics simulations for seven prototypic liquids--a molten inorganic salt, four ILs, a strongly polar organic solvent, and a weakly polar organic solvent, we have revealed that the depth of the cage energy landscape characterizes the ionic nature of ILs, whereas the slope and curvature of its mimimum determine the organic nature of ILs. This finding advances our understanding of ILs and thus will help their efficient utilization as well as the systematic design of novel functionalized ILs. PMID:26782660

  2. Dual Ionic and Organic Nature of Ionic Liquids

    PubMed Central

    Shi, Rui; Wang, Yanting

    2016-01-01

    Inherited the advantages of inorganic salts and organic solvents, ionic liquids (ILs) exhibit many superior properties allowing them promising green solvents for the future. Although it has been widely acknowledged that the unique features of ILs originate from their dual ionic and organic nature, its microscopic physical origin still remains blurry. In this work, by comparing the ion/molecule cage structures obtained from molecular dynamics simulations for seven prototypic liquids—a molten inorganic salt, four ILs, a strongly polar organic solvent, and a weakly polar organic solvent, we have revealed that the depth of the cage energy landscape characterizes the ionic nature of ILs, whereas the slope and curvature of its mimimum determine the organic nature of ILs. This finding advances our understanding of ILs and thus will help their efficient utilization as well as the systematic design of novel functionalized ILs. PMID:26782660

  3. Dual Ionic and Organic Nature of Ionic Liquids

    NASA Astrophysics Data System (ADS)

    Shi, Rui; Wang, Yanting

    2016-01-01

    Inherited the advantages of inorganic salts and organic solvents, ionic liquids (ILs) exhibit many superior properties allowing them promising green solvents for the future. Although it has been widely acknowledged that the unique features of ILs originate from their dual ionic and organic nature, its microscopic physical origin still remains blurry. In this work, by comparing the ion/molecule cage structures obtained from molecular dynamics simulations for seven prototypic liquids—a molten inorganic salt, four ILs, a strongly polar organic solvent, and a weakly polar organic solvent, we have revealed that the depth of the cage energy landscape characterizes the ionic nature of ILs, whereas the slope and curvature of its mimimum determine the organic nature of ILs. This finding advances our understanding of ILs and thus will help their efficient utilization as well as the systematic design of novel functionalized ILs.

  4. Quasiparticles and Fermi liquid behaviour in an organic metal

    PubMed Central

    Kiss, T.; Chainani, A.; Yamamoto, H.M.; Miyazaki, T.; Akimoto, T.; Shimojima, T.; Ishizaka, K.; Watanabe, S.; Chen, C.-T.; Fukaya, A.; Kato, R.; Shin, S.

    2012-01-01

    Many organic metals display exotic properties such as superconductivity, spin-charge separation and so on and have been described as quasi-one-dimensional Luttinger liquids. However, a genuine Fermi liquid behaviour with quasiparticles and Fermi surfaces have not been reported to date for any organic metal. Here, we report the experimental Fermi surface and band structure of an organic metal (BEDT-TTF)3Br(pBIB) obtained using angle-resolved photoelectron spectroscopy, and show its consistency with first-principles band structure calculations. Our results reveal a quasiparticle renormalization at low energy scales (effective mass m*=1.9 me) and ω2 dependence of the imaginary part of the self energy, limited by a kink at ~50 meV arising from coupling to molecular vibrations. The study unambiguously proves that (BEDT-TTF)3Br(pBIB) is a quasi-2D organic Fermi liquid with a Fermi surface consistent with Shubnikov-de Haas results. PMID:23011143

  5. Distinctive Nanoscale Organization of Dicationic versus Monocationic Ionic Liquids

    SciTech Connect

    Li, Song; Feng, Guang; Banuelos, Jose Leo; Rother, Gernot; Fulvio, Pasquale F; Dai, Sheng; Cummings, Peter T

    2013-01-01

    The distinctive structural organization of dicationic ionic liquids (DILs) with varying alkyl linkage chain lengths is systematically investigated using classical molecular dynamics (MD) simulations. In comparison with their counterparts, monocationic ionic liquids (MILs) with free alkyl chain, the DILs with short linkage chains exhibit almost identical structural features regardless of anion types, whereas the long-chain DILs display a relatively insignificant prepeak and low heterogeneity order parameter (HOP), which is accompanied by the less evident structural heterogeneity. Moreover, the predominant role of anion type in the structure of DILs was verified, similar to what is observed in MILs. Finally, the different nanoscale organizations in DILs and MILs are rationalized by the relatively unfavorable straight and folded chain models proposed for the nanoaggregates in DILs and the favorable micelle-like arrangement for those in MILs.

  6. Gas-liquid chromatography in lunar organic analysis.

    NASA Technical Reports Server (NTRS)

    Gehrke, C. W.

    1972-01-01

    Gas-liquid chromatography (GLC) is a powerful and sensitive method for the separation and detection of organic compounds at nanogram levels. The primary requirement for successful analyses is that the compounds of interest must be volatile under the chromatographic conditions employed. Nonvolatile organic compounds must be converted to volatile derivatives prior to analysis. The derivatives of choice must be both amenable to chromatographic separation and be relatively stable. The condition of volatility necessitates the development of efficient derivatization reactions for important groups of compounds as amino acids, carbohydrates, nucleosides, etc. Trimethylsilylation and trifluoroacetylation represent specific areas of recent prominence. Some relevant practical aspects of GLC are discussed.

  7. Variation in pH of Model Secondary Organic Aerosol during Liquid-Liquid Phase Separation.

    PubMed

    Dallemagne, Magda A; Huang, Xiau Ya; Eddingsaas, Nathan C

    2016-05-12

    The majority of atmospheric aerosols consist of both organic and inorganic components. At intermediate relative humidity (RH), atmospheric aerosol can undergo liquid-liquid phase separation (LLPS) in which the organic and inorganic fractions segregate from each other. We have extended the study of LLPS to the effect that phase separation has on the pH of the overall aerosols and the pH of the individual phases. Using confocal microscopy and pH sensitive dyes, the pH of internally mixed model aerosols consisting of polyethylene glycol 400 and ammonium sulfate as well as the pH of the organic fraction during LLPS have been directly measured. During LLPS, the pH of the organic fraction was observed to increase to 4.2 ± 0.2 from 3.8 ± 0.1 under high RH when the aerosol was internally mixed. In addition, the high spatial resolution of the confocal microscope allowed us to characterize the composition of each of the phases, and we have observed that during LLPS the organic shell still contains large quantities of water and should be characterized as an aqueous organic-rich phase rather than simply an organic phase. PMID:27082856

  8. Assay of organic liquid contents in predominantly water-wet unconsolidated porous media

    NASA Astrophysics Data System (ADS)

    Cary, J. W.; McBride, J. F.; Simmons, C. S.

    1991-11-01

    Immiscible organic liquids may be extracted from moist soil or other hydrophilic porous media by shaking a suspension of water and soil in a glass jar with a piece of porous polyethylene. The water displaces the organic liquid from the predominantly hydrophilic sample and the hydrophobic polyethylene preferentially absorbs the organic liquid, excluding water unless there is a detergent associated with the organic. Because most soils have some hydrophobic surfaces, the extraction of organic liquids by displacement with water is not quite complete. A correction is therefore made in the assay method by including samples with known organic liquid content as controls. The amount of organic liquid not displaced from the control samples can also be used to indicate the extent of hydrophobic sites in predominantly water-wet porous media. Organic liquid extractions were made by using three soils and two organic liquids. The standard deviation among replicated extractions was 0.010 g organic liquid. By applying a correction to the mass of organic liquid recovered, the assay accuracy was ±0.001 g organic liquid/g soil with 20.0-g oven-dry soil samples. It is likely that this assay method could be scaled up and used as a remediation method for removing and recovering organic liquids from earth excavated from spill or leak sites.

  9. Waveshifters and Scintillators for Ionizing Radiation Detection

    SciTech Connect

    B.Baumgaugh; J.Bishop; D.Karmgard; J.Marchant; M.McKenna; R.Ruchti; M.Vigneault; L.Hernandez; C.Hurlbut

    2007-12-11

    Scintillation and waveshifter materials have been developed for the detection of ionizing radiation in an STTR program between Ludlum Measurements, Inc. and the University of Notre Dame. Several new waveshifter materials have been developed which are comparable in efficiency and faster in fluorescence decay than the standard material Y11 (K27) used in particle physics for several decades. Additionally, new scintillation materials useful for fiber tracking have been developed which have been compared to 3HF. Lastly, work was done on developing liquid scintillators and paint-on scintillators and waveshifters for high radiation environments.

  10. Group extraction of organic compounds present in liquid samples

    NASA Technical Reports Server (NTRS)

    Jahnsen, Vilhelm J. (Inventor)

    1976-01-01

    An extraction device is disclosed comprising a tube containing a substantially inert, chemically non-reactive packing material with a large surface area to volume ratio. A sample which consists of organic compounds dissolved in a liquid, is introduced into the tube. As the sample passes through the packing material it spreads over the material's large surface area to form a thin liquid film which is held on the packing material in a stationary state. A particular group or family of compounds is extractable from the sample by passing a particular solvent system consisting of a solvent and selected reagents through the packing material. The reagents cause optimum conditions to exist for the compounds of the particular family to pass through the phase boundary between the sample liquid and the solvent of the solvent system. Thus, the compounds of the particular family are separated from the sample liquid and become dissolved in the solvent of the solvent system. The particular family of compounds dissolved in the solvent, representing an extract, exits the tube together with the solvent through the tube's nozzle, while the rest of the sample remains on the packing material in a stationary state. Subsequently, a different solvent system may be passed through the packing material to extract another family of compounds from the remaining sample on the packing material.

  11. Liquid crystals for organic thin-film transistors

    NASA Astrophysics Data System (ADS)

    Iino, Hiroaki; Usui, Takayuki; Hanna, Jun-Ichi

    2015-04-01

    Crystalline thin films of organic semiconductors are a good candidate for field effect transistor (FET) materials in printed electronics. However, there are currently two main problems, which are associated with inhomogeneity and poor thermal durability of these films. Here we report that liquid crystalline materials exhibiting a highly ordered liquid crystal phase of smectic E (SmE) can solve both these problems. We design a SmE liquid crystalline material, 2-decyl-7-phenyl-[1]benzothieno[3,2-b][1]benzothiophene (Ph-BTBT-10), for FETs and synthesize it. This material provides uniform and molecularly flat polycrystalline thin films reproducibly when SmE precursor thin films are crystallized, and also exhibits high durability of films up to 200 °C. In addition, the mobility of FETs is dramatically enhanced by about one order of magnitude (over 10 cm2 V-1 s-1) after thermal annealing at 120 °C in bottom-gate-bottom-contact FETs. We anticipate the use of SmE liquid crystals in solution-processed FETs may help overcome upcoming difficulties with novel technologies for printed electronics.

  12. Digital discrimination of neutrons and γ rays with organic scintillation detectors in an 8-bit sampling system using frequency gradient analysis

    NASA Astrophysics Data System (ADS)

    Yang, Jun; Luo, Xiao-Liang; Liu, Guo-Fu; Lin, Cun-Bao; Wang, Yan-Ling; Hu, Qing-Qing; Peng, Jin-Xian

    2012-06-01

    The feasibility of using frequency gradient analysis (FGA), a digital method based on Fourier transform, to discriminate neutrons and γ rays in the environment of an 8-bit sampling system has been investigated. The performances of most pulse shape discrimination methods in a scintillation detection system using the time-domain features of the photomultiplier tube anode signal will be lower or non-effective in this low resolution sampling system. However, the FGA method using the frequency-domain features of the anode signal exhibits a strong insensitivity to noise and can be used to discriminate neutrons and γ rays in the above sampling system. A detailed study of the quality of the FGA method in BC501A liquid scintillators is presented using a 5 G samples/s 8-bit oscilloscope and a 14.1 MeV neutron generator. A comparison of the discrimination results of the time-of-flight and conventional charge comparison (CC) methods proves the applicability of this technique. Moreover, FGA has the potential to be implemented in current embedded electronics systems to provide real-time discrimination in standalone instruments.

  13. Time-efficient method for the determination of 210Pb, 210Bi, and 210Po activities in seawater using liquid scintillation spectrometry.

    PubMed

    Biggin, Colin D; Cook, Gordon T; MacKenzie, Angus B; Pates, Jacqueline M

    2002-02-01

    A novel method has been developed for determining the natural decay series radionuclides (NDS), 210Pb, 210Bi, and 210Po, in seawater by way of state-of-the-art liquid scintillation spectrometry. For 210Pb analysis, the method makes use of a 212Pb yield tracer, prepared by ion exchange separation from aged Th(NO3)4. 210Bi recovery is determined using 207Bi as the yield tracer, and 210Po is determined using the conventional 208Po yield tracer. The limits of detection for this method are 0.32, 0.34, and 0.004 mBq 1-1 for 210Pb, 210Bi, and 210Po, respectively. The analysis can be completed within 10 days, as compared with up to one year for traditional methods. Results are presented for a preliminary study of 210Pb, 210Bi, and 210Po in the dissolved and particle-bound phases of Irish Sea water. PMID:11838694

  14. Monte Carlo simulation of prompt γ-ray spectra from depleted uranium under D-T neutron irradiation and electron recoil spectra in a liquid scintillator detector

    NASA Astrophysics Data System (ADS)

    Jian-Guo, Qin; Cai-Feng, Lai; Rong, Liu; Tong-Hua, Zhu; Xin-Wei, Zhang; Bang-Jiao, Ye

    2016-03-01

    To overcome the problem of inefficient computing time and unreliable results in MCNP5 calculation, a two-step method is adopted to calculate the energy deposition of prompt γ-rays in detectors for depleted uranium spherical shells under D-T neutron irradiation. In the first step, the γ-ray spectrum for energy below 7 MeV is calculated by MCNP5 code; secondly, the electron recoil spectrum in a BC501A liquid scintillator detector is simulated based on EGSnrc Monte Carlo Code with the γ-ray spectrum from the first step as input. The comparison of calculated results with experimental ones shows that the simulations agree well with experiment in the energy region 0.4-3 MeV for the prompt γ-ray spectrum and below 4 MeVee for the electron recoil spectrum. The reliability of the two-step method in this work is validated. Supported by the National Natural Science Foundation of China (91226104) and National Special Magnetic Confinement Fusion Energy Research, China (2015GB108001)

  15. Determination of ⁹⁰Sr and ²¹⁰Pb in sludge samples using a LOV-MSFIA system and liquid scintillation counting.

    PubMed

    Mola, M; Avivar, J; Nieto, A; Peñalver, A; Aguilar, C; Ferrer, L; Cerdà, V; Borrull, F

    2014-04-01

    There has been increasing interest recently in the capacity of water treatment plants to concentrate and eliminate radionuclides from raw water. As the normal operation in these plants generates high quantities of sludge, which can be considered a naturally occurring radioactive material, it is important to gather information about its radiological content. Therefore, in order to determine the activity values of two radioactive beta emitters with minimal sample manipulation, an automated lab-on-valve and multisyringe flow injection system has been developed to achieve the sequential preconcentration and separation of (90)Sr and (210)Pb using an extraction chromatographic resin (Sr-spec). Activities of both isotopes were measured by liquid scintillation counting (LSC). The developed method was validated by analyzing three samples from three different intercomparison exercises and good Z-score values (between 0.1 and 1) and trueness values (between 10% and 17%) were obtained. The method was then also satisfactorily applied to sludge samples taken from a Spanish drinking water treatment plant which treats water from the Ebro River. The proposed method offers advantages over existing methods as it allows the sequential separation of both isotopes, simply by changing the elution conditions and using a semi-automated approach. Therefore, the method is less time consuming and environmentally friendly. PMID:24462943

  16. SCINTILLATION SPECTROMETER

    DOEpatents

    Bell, P.R.; Francis, J.E.

    1960-06-21

    A portable scintillation spectrometer is described which is especially useful in radio-biological studies for determining the uptake and distribution of gamma -emitting substances in tissue. The spectrometer includes a collimator having a plurality of apertures that are hexagonal in cross section. Two crystals are provided: one is activated to respond to incident rays from the collimator; the other is not activated and shields the first from external radiation.

  17. The aquatic impact of ionic liquids on freshwater organisms.

    PubMed

    Costa, Susana P F; Pinto, Paula C A G; Saraiva, M Lúcia M F S; Rocha, Fábio R P; Santos, Joyce R P; Monteiro, Regina T R

    2015-11-01

    Ionic liquids (ILs), also known as liquid electrolytes, are powerful solvents with a wide variety of academic and industrial applications. Bioassays with aquatic organisms constitute an effective tool for the evaluation of ILs' toxicity, as well as for the prediction and identification of possible moieties that act as toxicophores. In this work, the acute toxicity of six ILs and two commonly used organic solvents was evaluated using freshwater organisms: Daphnia magna, Raphidocelis subcapitata and Hydra attenuata. The bioassays were performed by exposing the organisms to increasing concentrations of the ILs and observing D. magna immobilization, R. subcapitata growth inhibition, and the morphological or mortality effects in H. attenuata. The results demonstrate that the tested organisms are not equally susceptible to the ILs, e.g., bmpyr [BF4] was the least toxic compound for R. subcapitata, N1,1 [N1,1,1OOH] for D. magna and emim [Tf2N] for H. attenuata. This highlights the importance of applying a battery of assays in toxicological analysis. Additionally, Hydra proved to be the most tolerant species to the tested ILs. According to their hazard rankings, the tested ILs are considered practically harmless or moderately toxic, except (Hex)3(TDec)P [Cl], which was classified as highly toxic. The ILs were revealed to be more harmful to aquatic systems than the tested organic solvents, reaffirming the need to analyze carefully the (eco)toxicological impact of these compounds. The present study provides additional data in the evaluation of the potential hazard and the impact of ILs in the environment. PMID:26151376

  18. Use of metal organic fluors for spectral discrimination of neutrons and gammas.

    SciTech Connect

    Allendorf, Mark D.; Doty, F. Patrick; Feng, Patrick L.

    2010-09-01

    A new method for spectral shape discrimination (SSD) of fast neutrons and gamma rays has been investigated. Gammas interfere with neutron detection, making efficient discrimination necessary for practical applications. Pulse shape discrimination (PSD) in liquid organic scintillators is currently the most effective means of gamma rejection. The hazardous liquids, restrictions on volume, and the need for fast timing are drawbacks to traditional PSD scintillators. In this project we investigated harvesting excited triplet states to increase scintillation yield and provide distinct spectral signatures for gammas and neutrons. Our novel approach relies on metal-organic phosphors to convert a portion of the energy normally lost to the scintillation process into useful luminescence with sub-microsecond lifetimes. The approach enables independent control over delayed luminescence wavelength, intensity, and timing for the first time. We demonstrated that organic scintillators, including plastics, nanoporous framework materials, and oil-based liquids can be engineered for both PSD and SSD.

  19. Plastic scintillation dosimetry: Optimal selection of scintillating fibers and scintillators

    SciTech Connect

    Archambault, Louis; Arsenault, Jean; Gingras, Luc; Sam Beddar, A.; Roy, Rene; Beaulieu, Luc

    2005-07-15

    Scintillation dosimetry is a promising avenue for evaluating dose patterns delivered by intensity-modulated radiation therapy plans or for the small fields involved in stereotactic radiosurgery. However, the increase in signal has been the goal for many authors. In this paper, a comparison is made between plastic scintillating fibers and plastic scintillator. The collection of scintillation light was measured experimentally for four commercial models of scintillating fibers (BCF-12, BCF-60, SCSF-78, SCSF-3HF) and two models of plastic scintillators (BC-400, BC-408). The emission spectra of all six scintillators were obtained by using an optical spectrum analyzer and they were compared with theoretical behavior. For scintillation in the blue region, the signal intensity of a singly clad scintillating fiber (BCF-12) was 120% of that of the plastic scintillator (BC-400). For the multiclad fiber (SCSF-78), the signal reached 144% of that of the plastic scintillator. The intensity of the green scintillating fibers was lower than that of the plastic scintillator: 47% for the singly clad fiber (BCF-60) and 77% for the multiclad fiber (SCSF-3HF). The collected light was studied as a function of the scintillator length and radius for a cylindrical probe. We found that symmetric detectors with nearly the same spatial resolution in each direction (2 mm in diameter by 3 mm in length) could be made with a signal equivalent to those of the more commonly used asymmetric scintillators. With augmentation of the signal-to-noise ratio in consideration, this paper presents a series of comparisons that should provide insight into selection of a scintillator type and volume for development of a medical dosimeter.

  20. Thermochemical Energy Storage through De/Hydrogenation of Organic Liquids: Reactions of Organic Liquids on Metal Hydrides.

    PubMed

    Ulmer, Ulrich; Cholewa, Martin; Diemant, Thomas; Bonatto Minella, Christian; Dittmeyer, Roland; Behm, R Jürgen; Fichtner, Maximilian

    2016-06-01

    A study of the reactions of liquid acetone and toluene on transition metal hydrides, which can be used in thermal energy or hydrogen storage applications, is presented. Hydrogen is confined in TiFe, Ti0.95Zr0.05Mn1.49V0.45Fe0.06 ("Hydralloy C5"), and V40Fe8Ti26Cr26 after contact with acetone. Toluene passivates V40Fe8Ti26Cr26 completely for hydrogen desorption while TiFe is only mildly deactivated and desorption is not blocked at all in the case of Hydralloy C5. LaNi5 is inert toward both organic liquids. Gas chromatography (GC) investigations reveal that CO, propane, and propene are formed during hydrogen desorption from V40Fe8Ti26Cr26 in liquid acetone, and methylcyclohexane is formed in the case of liquid toluene. These reactions do not occur if dehydrogenated samples are used, which indicates an enhanced surface reactivity during hydrogen desorption. Significant amounts of carbon-containing species are detected at the surface and subsurface of acetone- and toluene-treated V40Fe8Ti26Cr26 by X-ray photoelectron spectroscopy (XPS). The modification of the surface and subsurface chemistry and the resulting blocking of catalytic sites is believed to be responsible for the containment of hydrogen in the bulk. The surface passivation reactions occur only during hydrogen desorption of the samples. PMID:27183004

  1. Neutron response characterization for an EJ299-33 plastic scintillation detector

    SciTech Connect

    Lawrence, Chris C.; Febbraro, Michael; Massey, Thomas N.; Flaska, Marek; Becchetti, F. D.; Pozzi, Sara A.

    2014-05-10

    Organic scintillation detectors have shown promise as neutron detectors for characterizing special nuclear materials in various arms-control and homeland security applications. Recent advances have yielded a new plastic scintillator - EJ299-33 - with pulse-shape-discrimination (PSD) capability. Plastic scintillators would have a much expanded range of deployment relative to liquids and crystals. Here, we present a full characterization of pulse height response to fission-energy neutrons for an EJ299-33 detector with 7.62-by-7.62-cm cylindrical active volume, and compare with an EJ309 liquid scintillator in the same assembly. Scintillation light output relations, energy resolutions, and response matrices are presented for both detectors. A Continuous spectrum neutron source, obtained via the bombardment of Al-27 with 7.44-MeV deuterons at the Edwards Accelerator Facility at Ohio University, was used for the measurement. A new procedure for evaluating and comparing PSD performance is presented which accounts for the effect of the light output relation on the ability to detect low energy neutrons. The EJ299-33 is shown to have considerable deficit in matrix condition, and in PSD figure of merit when compared to EJ309, especially when neutron energy is taken into account. Furthermore the EJ299 is likely to bring a modest PSD capability into a array of held applications that are not accessible to liquids or crystals. (C) 2014 Elsevier B.V. All rights reserved. Keywords

  2. Neutron response characterization for an EJ299-33 plastic scintillation detector

    DOE PAGESBeta

    Lawrence, Chris C.; Febbraro, Michael; Massey, Thomas N.; Flaska, Marek; Becchetti, F. D.; Pozzi, Sara A.

    2014-05-10

    Organic scintillation detectors have shown promise as neutron detectors for characterizing special nuclear materials in various arms-control and homeland security applications. Recent advances have yielded a new plastic scintillator - EJ299-33 - with pulse-shape-discrimination (PSD) capability. Plastic scintillators would have a much expanded range of deployment relative to liquids and crystals. Here, we present a full characterization of pulse height response to fission-energy neutrons for an EJ299-33 detector with 7.62-by-7.62-cm cylindrical active volume, and compare with an EJ309 liquid scintillator in the same assembly. Scintillation light output relations, energy resolutions, and response matrices are presented for both detectors. A Continuousmore » spectrum neutron source, obtained via the bombardment of Al-27 with 7.44-MeV deuterons at the Edwards Accelerator Facility at Ohio University, was used for the measurement. A new procedure for evaluating and comparing PSD performance is presented which accounts for the effect of the light output relation on the ability to detect low energy neutrons. The EJ299-33 is shown to have considerable deficit in matrix condition, and in PSD figure of merit when compared to EJ309, especially when neutron energy is taken into account. Furthermore the EJ299 is likely to bring a modest PSD capability into a array of held applications that are not accessible to liquids or crystals. (C) 2014 Elsevier B.V. All rights reserved. Keywords« less

  3. Neutron response characterization for an EJ299-33 plastic scintillation detector

    NASA Astrophysics Data System (ADS)

    Lawrence, Chris C.; Febbraro, Michael; Massey, Thomas N.; Flaska, Marek; Becchetti, F. D.; Pozzi, Sara A.

    2014-09-01

    Organic scintillation detectors have shown promise as neutron detectors for characterizing special nuclear materials in various arms-control and homeland-security applications. Recent advances have yielded a new plastic scintillator - EJ299-33 - with pulse-shape-discrimination (PSD) capability. Plastic scintillators would have a much-expanded range of deployment relative to liquids and crystals. Here, we present a full characterization of pulse-height response to fission-energy neutrons for an EJ299-33 detector with 7.62-by-7.62-cm cylindrical active volume, and compare with an EJ309 liquid scintillator in the same assembly. Scintillation light-output relations, energy resolutions, and response matrices are presented for both detectors. A continuous-spectrum neutron source, obtained via the bombardment of 27Al with 7.44-MeV deuterons at the Edwards Accelerator Facility at Ohio University, was used for the measurement. A new procedure for evaluating and comparing PSD performance is presented which accounts for the effect of the light-output relation on the ability to detect low-energy neutrons. The EJ299-33 is shown to have considerable deficit in matrix condition, and in PSD figure of merit when compared to EJ309, especially when neutron energy is taken into account. Nevertheless the EJ299 is likely to bring a modest PSD capability into a array of field applications that are not accessible to liquids or crystals.

  4. Method for controlling viscosity of organic liquid and compositions

    SciTech Connect

    Kitano, K.; Duvdevani, I.; Schulz, D.N.

    1989-11-14

    This patent describes a method of viscosifying an organic liquid from about 10 to about 10,000 cps for polymer concentrations of less than about 10.0 wt.%. The method comprises adding a sufficient quantity of a hydrolyzed ester containing copolymer of an alpha-olefin and a vinyl alkylenecarboxylil acid copolymerized in the presence of a Ziegler-Natta catalyst having an acid content of from about 0.01 to 10 mole percent and a molecular weight of about 100,000 to about 10,000,000.

  5. The Use of Isotope Dilution Alpha Spectrometry and Liquid Scintillation Counting to Determine Radionuclides in Environmental Samples

    SciTech Connect

    Bylyku, Elida

    2009-04-19

    In Albania in recent years it has been of increasing interest to determine various pollutants in the environment and their possible effects on human health. The radiochemical procedure used to identify Pu, Am, U, Th, and Sr radioisotopes in soil, sediment, water, coal, and milk samples is described. The analysis is carried out in the presence of respective tracer solutions and combines the procedure for Pu analysis based on anion exchange, the selective method for Sr isolation based on extraction chromatography using Sr-Spec resin, and the application of the TRU-Spec column for separation of Am fraction. An acid digestion method has been applied for the decomposition of samples. The radiochemical procedure involves the separation of Pu from Th, Am, and Sr by anion exchange, followed by the preconcentration of Am and Sr by coprecipitation with calcium oxalate. Am is separated from Sr by extraction chromatography. Uranium is separated from the bulk elements by liquid-liquid extraction using UTEVA registered resin. Thin sources for alpha spectrometric measurements are prepared by microprecipitation with NdF3. Two International Atomic Energy Agency reference materials were analyzed in parallel with the samples.

  6. Comparison of capillary pressure relationships of organic liquid water systems containing an organic acid or base

    NASA Astrophysics Data System (ADS)

    Lord, D. L.; Demond, A. H.; Hayes, K. F.

    2005-04-01

    The presence of surface-active solutes such as organic acids and bases may have a profound influence on the transport of organic liquid contaminants through their impact on the constitutive relationship of capillary pressure vs. saturation. This relationship is a function of the interfacial tension and wettability of the system, which, in turn, depend on the pH and the concentration of organic acids and bases that are present. This study examines the impact of pH and the concentration on the interfacial tension, contact angle, and capillary pressure of systems consisting of tetrachloroethylene, water, and quartz containing either octanoic acid or dodecylamine. In general, the ionic form of the solute tended to remain in the aqueous phase and reduced the capillary pressure through its impact on the interfacial tension and contact angle; on the other hand, the neutral form of the solute partitioned into the organic liquid phase and had a lesser impact on the capillary pressure for the same total mass of solute. A comparison of these data with data generated in previous research in similar systems where o-xylene was the organic liquid showed that the trends are analogous. Thus, the behavior of these two solvent systems seems to be driven primarily by the aqueous phase speciation of the solute, and the differences between the capillary pressure relationships for the two systems could be attributed to the pure system interfacial tension.

  7. Liquid templating for nanoparticle organization into complex patterns.

    PubMed

    Rezende, Camila A; Lee, Lay-Theng; Galembeck, Fernando

    2007-02-27

    Dewetting of thin films of charged polymer solutions produces complex patterns that can be applied to direct nanoparticle organization on solid substrates. The morphology produced by dewetting can be controlled by the solution properties, temperature, and substrate wetting. In this work, new results on this liquid-template self-assembly system are presented, with special emphasis on producing large arrays of organized nanoparticles. On a hydrophilic substrate with complete wetting, the patterns include polygonal networks and parallel-track arrays that extend over several hundreds of microns. These large structures are formed under well-controlled drying conditions and characterized by scanning electron microscopy, which is better suited for the examination of large as well as small areas than atomic force microscopy. On partial wetting substrates, new patterns are observed, including a complex set of parallel curved bands with variable particle number densities. PMID:17309221

  8. Broad energy range neutron spectroscopy using a liquid scintillator and a proportional counter: Application to a neutron spectrum similar to that from an improvised nuclear device

    NASA Astrophysics Data System (ADS)

    Xu, Yanping; Randers-Pehrson, Gerhard; Marino, Stephen A.; Garty, Guy; Harken, Andrew; Brenner, David J.

    2015-09-01

    A novel neutron irradiation facility at the Radiological Research Accelerator Facility (RARAF) has been developed to mimic the neutron radiation from an Improvised Nuclear Device (IND) at relevant distances (e.g. 1.5 km) from the epicenter. The neutron spectrum of this IND-like neutron irradiator was designed according to estimations of the Hiroshima neutron spectrum at 1.5 km. It is significantly different from a standard reactor fission spectrum, because the spectrum changes as the neutrons are transported through air, and it is dominated by neutron energies from 100 keV up to 9 MeV. To verify such wide energy range neutron spectrum, detailed here is the development of a combined spectroscopy system. Both a liquid scintillator detector and a gas proportional counter were used for the recoil spectra measurements, with the individual response functions estimated from a series of Monte Carlo simulations. These normalized individual response functions were formed into a single response matrix for the unfolding process. Several accelerator-based quasi-monoenergetic neutron source spectra were measured and unfolded to test this spectroscopy system. These reference neutrons were produced from two reactions: T(p,n)3He and D(d,n)3He, generating neutron energies in the range between 0.2 and 8 MeV. The unfolded quasi-monoenergetic neutron spectra indicated that the detection system can provide good neutron spectroscopy results in this energy range. A broad-energy neutron spectrum from the 9Be(d,n) reaction using a 5 MeV deuteron beam, measured at 60 degrees to the incident beam was measured and unfolded with the evaluated response matrix. The unfolded broad neutron spectrum is comparable with published time-of-flight results. Finally, the pair of detectors were used to measure the neutron spectrum generated at the RARAF IND-like neutron facility and a comparison is made to the neutron spectrum of Hiroshima.

  9. Simultaneous measurement of Rn and its progeny in cave air by liquid scintillation techniques and. cap alpha. -ray spectrometry

    SciTech Connect

    Amano, H.; Kasai, A.; Matsunaga, T.

    1985-09-01

    To estimate the internal dose from Rn and its progeny, the working level month which is defined as exposure at one working level concentration for 170 h has been used traditionally. But concerning dose calculated for the inhalation of Rn and its progeny to the public, dose factors from individual nuclides were recommended. The approach using individual dose factors requires determination of the concentration of these individual nuclides. Thus a simultaneous measurement of Rn and its progeny was made in an enclosed cave, which is used for seismological observation, since the problem is most acute in an enclosed environment and the situation is not so complicated under such circumstances. Radon sampling by adsorption in organic solvent and in-situ ..cap alpha..-ray spectrometry of Rn progeny have been carried out in this cave. The internal dose by inhalation is estimated for the workers in this cave.

  10. Poly(ionic liquid) superabsorbent for polar organic solvents.

    PubMed

    Horne, W Jeffrey; Andrews, Mary A; Terrill, Kelsey L; Hayward, Spenser S; Marshall, Jeannie; Belmore, Kenneth A; Shannon, Matthew S; Bara, Jason E

    2015-05-01

    A simple, polymerized ionic liquid (poly(IL)) based on methylimidazolium cations tethered to a polystyrene backbone exhibits superabsorbent behavior toward polar organic solvents, most notably propylene carbonate (PC) and dimethyl sulfoxide (DMSO), wherein the poly(IL) was observed to swell more than 390 and 200 times (w/w) its original mass, yet absorbs negligible quantities of water, hexanes, and other solvents, many of which were miscible with the IL monomer. Although solubility parameters and dielectric constants are typically used to rationalize such behaviors, we find that poly(IL)-solvent compatibility is most clearly correlated to solvent dipole moment. Poly(IL) superabsorbency is not reliant upon the addition of a cross-linking agent. PMID:25893981

  11. Removal of organic impurities from liquid carbon dioxide

    NASA Astrophysics Data System (ADS)

    Zito, Richard R.

    2002-09-01

    The use of a high velocity stream of carbon dioxide snowflakes to clean large optics is well known, and has gained widespread acceptance in the astronomical community as a telescope maintenance technique. Ultimately, however, the success of carbon dioxide snow cleaning depends on the availability of high purity carbon dioxide. The higher the purity of the carbon dioxide, the longer will be the time interval between required mirror washings. The highest grades of commercially produced liquid carbon dioxide are often not available in the more remote regions of the world - such as where major astronomical observatories are often located. Furthermore, the purity of even the highest grades of carbon dioxide are only nominal, and wide variations are known to occur from tank to tank. Occasionally, visible deposits of organic impurities are left behind during cleaning with carbon dioxide that is believed to be 99.999% pure. A zeolite molecular sieve based filtration system has proven to be very effective in removing these organic impurities. A zeolite is a complex alumino-silicate. One example has an empirical formula of Na2O(Al2O3)(SiO2)2yH2O, where y=0 to 8. The zeolites have an open crystal structure and are capable of trapping impurities like 8-methylheptadecane (an oil) and 2,6-octadine-1-ol,3,7- dimethyl-,(E)- (a fatty acid). In fact, a zeolite can trap 29.5% of its own weight in SAE 20 lubricant at 25 degree(s)C. After filtration of liquid CO2 through zeolites, the concentration of measured impurities was below the detection limit for state-of-the-art gas chromatography systems.

  12. Catalytic conversion of nonfood woody biomass solids to organic liquids.

    PubMed

    Barta, Katalin; Ford, Peter C

    2014-05-20

    This Account outlines recent efforts in our laboratories addressing a fundamental challenge of sustainability chemistry, the effective utilization of biomass for production of chemicals and fuels. Efficient methods for converting renewable biomass solids to chemicals and liquid fuels would reduce society's dependence on nonrenewable petroleum resources while easing the atmospheric carbon dioxide burden. The major nonfood component of biomass is lignocellulose, a matrix of the biopolymers cellulose, hemicellulose, and lignin. New approaches are needed to effect facile conversion of lignocellulose solids to liquid fuels and to other chemical precursors without the formation of intractable side products and with sufficient specificity to give economically sustainable product streams. We have devised a novel catalytic system whereby the renewable feedstocks cellulose, organosolv lignin, and even lignocellulose composites such as sawdust are transformed into organic liquids. The reaction medium is supercritical methanol (sc-MeOH), while the catalyst is a copper-doped porous metal oxide (PMO) prepared from inexpensive, Earth-abundant starting materials. This transformation occurs in a single stage reactor operating at 300-320 °C and 160-220 bar. The reducing equivalents for these transformations are derived by the reforming of MeOH (to H2 and CO), which thereby serves as a "liquid syngas" in the present case. Water generated by deoxygenation processes is quickly removed by the water-gas shift reaction. The Cu-doped PMO serves multiple purposes, catalyzing substrate hydrogenolysis and hydrogenation as well as the methanol reforming and shift reactions. This one-pot "UCSB process" is quantitative, giving little or no biochar residual. Provided is an overview of these catalysis studies beginning with reactions of the model compound dihydrobenzofuran that help define the key processes occurring. The initial step is phenyl-ether bond hydrogenolysis, and this is followed by

  13. Reactive Uptake of Ammonia and Formation of Organic Nitrogen Species for Non-Liquid/Liquid Secondary Organic Material

    NASA Astrophysics Data System (ADS)

    Martin, S. T.; Li, Y.; Liu, P.

    2015-12-01

    Formation of ammonium and organic nitrogen (ON) species was studied for secondary organic material (SOM) of variable viscosity, ranging from non-liquid to liquid physical states. The SOM was produced as particles of 50 to 150 nm in diameter in aerosol form from six precursors, including three terpenoid and three aromatic species. The viscosity of the hygroscopic SOM was adjusted by exposure to relative humidity (RH) from <5% to >90% RH in steps of 10% at 293 ± 2 K. The aerosol was subsequently exposed to 5 ppm NH3 for mean reaction times of 30, 370, or 5230 s. Ammonium and ON were characterized by high-resolution time-of-flight aerosol mass spectrometry (HR-ToF-AMS). The ammonium-to-organic ratio of mass concentrations (MNH4/MOrg) in the particles increased monotonically from <5% RH to a limiting value at a threshold RH, implicating a switchover in the reaction kinetics from a system limited by diffusivity within the SOM for low RH to one limited by other factors, such as saturated uptake, at higher RH. Formation of ON was observed for aromatic-derived SOMs, but not significant for terpenoid-derived SOMs. For aromatic-derived SOMs, the ON-to-organic ratio of mass concentrations (MON/MOrg) was negligible for RH <20%, increased monotonically from 20% to 60% RH, and stayed constant for RH >60%. The threshold RH for the switchover from kinetically controlled regime to a non-kinetically-controlled one was thus different between formation of ammonium and ON. This difference suggests that water may play a role in the slow reactions of ON formation as a reactant or a catalyst, in addition to affecting the reactant diffusion as in the fast reaction of ammonium formation. The implication is that formation of ammonium salts and organic nitrogen species by certain SOMs should be treated separately in chemical transport models to reflect the different roles of water that may affect the phase state of the SOMs or may act as a reactant or a catalyst.

  14. Investigation of the organic matter in inactive nuclear tank liquids. Environmental Restoration Program

    SciTech Connect

    Schenley, R.L.; Griest, W.H.

    1990-08-01

    Environmental Protection Agency (EPA) methodology for regulatory organics fails to account for the organic matter that is suggested by total organic carbon (TOC) analysis in the Oak Ridge National Laboratory (ORNL) inactive nuclear waste-tank liquids and sludges. Identification and measurement of the total organics are needed to select appropriate waste treatment technologies. An initial investigation was made of the nature of the organics in several waste-tank liquids. This report details the analysis of ORNL wastes.

  15. Azobenzene-based organic salts with ionic liquid and liquid crystalline properties

    DOE PAGESBeta

    Stappert, Kathrin; Muthmann, Johanna; Spielberg, Eike T.; Mudring, Anja -Verena

    2015-07-23

    Two sets of new azobenzene-based bromide salts are synthesized, and their thermal photochromic properties are studied. Both sets are based on the imidazolium cation. The first set (1) features a symmetric biscation where two imidazolium head groups (Im) with different alkyl chains (Cn) are connected to a central azobenzene unit (Azo): [Azo(C1-Im-Cn)2]; n = 6, 8, 10, 12, 14. The other one contains an n-alkyl-imidazolium cation (Cn-Im) bearing a terminal azobenzene unit (C1-Azo) substituted with an alkoxy chain (O-Cm) of either two (2) or six (3) carbon atoms: [C1-Azo-O-Cm-Im-Cn]; m = 2, n = 8, 10, 12 and m =more » 6, n = 8, 10, 12, 14, 16. For both cation classes, the influence of alkyl chains of varying length on the thermal phase behavior was investigated by differential scanning calorimetry (DSC) and polarizing optical microscopy (POM). For five compounds (Azo(-C1-Im-C12)2 (1d), Azo(-C1-Im-C12)2 (1e), C1-Azo-O-C2-Im-C10 (2b), C1-Azo-O-C2-Im-C12 (2c), and C1-Azo-O-C6-Im-C16 (3e)), the formation of a liquid crystalline phase was observed. The biscationic salts (1) are all comparatively high melting organic salts (180–240 °C), and only the two representatives with long alkylchains (C12 and C14) exhibit liquid crystallinity. The monocationic salts with an O–C2 bridge (2) melt between 140 and 170 °C depending on the alkyl chain length, but from an alkyl chain of 10 and more carbon atoms on they form a smectic A liquid crystalline phase. The representatives of the third set with a O–C6 bridge qualify as ionic liquids with melting points less than 100 °C. However, only the representative with a hexadecyl chain forms a liquid crystalline phase. Representative single crystals for all sets of cations could be grown that allowed for single crystal structure analysis. Together with small-angle X-ray scattering experiments they allow for a more detailed understanding of the thermal properties. As a result, through irradiation with UV-light (320–366 nm) all

  16. Azobenzene-based organic salts with ionic liquid and liquid crystalline properties

    SciTech Connect

    Stappert, Kathrin; Muthmann, Johanna; Spielberg, Eike T.; Mudring, Anja -Verena

    2015-07-23

    Two sets of new azobenzene-based bromide salts are synthesized, and their thermal photochromic properties are studied. Both sets are based on the imidazolium cation. The first set (1) features a symmetric biscation where two imidazolium head groups (Im) with different alkyl chains (Cn) are connected to a central azobenzene unit (Azo): [Azo(C1-Im-Cn)2]; n = 6, 8, 10, 12, 14. The other one contains an n-alkyl-imidazolium cation (Cn-Im) bearing a terminal azobenzene unit (C1-Azo) substituted with an alkoxy chain (O-Cm) of either two (2) or six (3) carbon atoms: [C1-Azo-O-Cm-Im-Cn]; m = 2, n = 8, 10, 12 and m = 6, n = 8, 10, 12, 14, 16. For both cation classes, the influence of alkyl chains of varying length on the thermal phase behavior was investigated by differential scanning calorimetry (DSC) and polarizing optical microscopy (POM). For five compounds (Azo(-C1-Im-C12)2 (1d), Azo(-C1-Im-C12)2 (1e), C1-Azo-O-C2-Im-C10 (2b), C1-Azo-O-C2-Im-C12 (2c), and C1-Azo-O-C6-Im-C16 (3e)), the formation of a liquid crystalline phase was observed. The biscationic salts (1) are all comparatively high melting organic salts (180–240 °C), and only the two representatives with long alkylchains (C12 and C14) exhibit liquid crystallinity. The monocationic salts with an O–C2 bridge (2) melt between 140 and 170 °C depending on the alkyl chain length, but from an alkyl chain of 10 and more carbon atoms on they form a smectic A liquid crystalline phase. The representatives of the third set with a O–C6 bridge qualify as ionic liquids with melting points less than 100 °C. However, only the representative with a hexadecyl chain forms a liquid crystalline phase. Representative single crystals for all sets of cations could be grown that allowed for single crystal structure analysis. Together with small-angle X-ray scattering experiments they allow for a more detailed understanding of the thermal properties. As a result, through irradiation with UV

  17. Discotic liquid crystals: a new generation of organic semiconductors.

    PubMed

    Sergeyev, Sergey; Pisula, Wojciech; Geerts, Yves Henri

    2007-12-01

    Discotic (disc-like) molecules typically comprising a rigid aromatic core and flexible peripheral chains have been attracting growing interest because of their fundamental importance as model systems for the study of charge and energy transport and due to the possibilities of their application in organic electronic devices. This critical review covers various aspects of recent research on discotic liquid crystals, in particular, molecular design concepts, supramolecular structure, processing into ordered thin films and fabrication of electronic devices. The chemical structure of the conjugated core of discotic molecules governs, to a large extent, their intramolecular electronic properties. Variation of the peripheral flexible chains and of the aromatic core is decisive for the tuning of self-assembly in solution and in bulk. Supramolecular organization of discotic molecules can be effectively controlled by the choice of the processing methods. In particular, approaches to obtain suitable macroscopic orientations of columnar superstructures on surfaces, that is, planar uniaxial or homeotropic alignment, are discussed together with appropriate processing techniques. Finally, an overview of charge transport in discotic materials and their application in optoelectronic devices is given. PMID:17982517

  18. Incineration of radioactive organic liquid wastes by underwater thermal plasma

    NASA Astrophysics Data System (ADS)

    Mabrouk, M.; Lemont, F.; Baronnet, J. M.

    2012-12-01

    This work deals with incineration of radioactive organic liquid wastes using an oxygen thermal plasma jet, submerged under water. The results presented here are focused on incineration of three different wastes: a mixture of tributylphosphate (TBP) and dodecane, a perfluoropolyether oil (PFPE) and trichloroethylene (TCE). To evaluate the plutonium behavior in used TBP/dodecane incineration, zirconium is used as a surrogate of plutonium; the method to enrich TBP/dodecane mixture in zirconium is detailed. Experimental set-up is described. During a trial run, CO2 and CO contents in the exhaust gas are continuously measured; samples, periodically taken from the solution, are analyzed by appropriate chemical methods: contents in total organic carbon (COT), phosphorus, fluoride and nitrates are measured. Condensed residues are characterized by RX diffraction and SEM with EDS. Process efficiency, during tests with a few L/h of separated or mixed wastes, is given by mineralization rate which is better than 99.9 % for feed rate up to 4 L/h. Trapping rate is also better than 99 % for phosphorous as for fluorine and chlorine. Those trials, with long duration, have shown that there is no corrosion problems, also the hydrogen chloride and fluoride have been neutralized by an aqueous solution of potassium carbonate.

  19. Improvement of natural pastures using liquid organic fertilizers

    NASA Astrophysics Data System (ADS)

    Ghambashidze, Giorgi; Gabedava, Giorgi; Abuladze, Paata

    2016-04-01

    Nowadays natural pastures remains the main source to supply livestock with fresh feed material in Georgia. Due to that common pasturelands are under continues grazing pressure and normally no measures are taken in order to improve pasture productivity and to protect soil from erosion. Unregulated stocking rate leads to overutilization of natural pastures causing reduction in productivity and soil fertility. It is especially evident in arid regions, where bare soil after removal of vegetation dries out and is subject to wind erosion. In many areas even with regulated stocking rate plant available soil nutrient pool is already diminished and vegetation cannot be recovered easily after grazing. Therefore it is essential to improve soil fertility, which provide adequate amount of nutrients to plants to regenerate. Ongoing study aims to compare effect of different types of organic fertilizers on natural pastures in combination with pasture rotation scheme in order to maintain soil fertility and prepare the basis for its gradual improvement. Initial results shows positive impact of liquid organic fertilizers which increased aboveground biomass production by 200-300 kg per hectare.

  20. Measurement of light emission in scintillation vials

    SciTech Connect

    Duran Ramiro, M. Teresa; Garcia-Torano, Eduardo

    2005-09-15

    The efficiency and energy resolution of liquid scintillation counting (LSC) systems are strongly dependent on the optical characteristics of scintillators, vials, and reflectors. This article presents the results of measurements of the light-emission profile of scintillation vials. Two measurement techniques, autoradiographs and direct measurements with a photomultiplier tube, have been used to obtain light-emission distribution for standard vials of glass, etched glass and polyethylene. Results obtained with both techniques are in good agreement. For the first time, the effect of the meniscus in terms of light contribution has been numerically estimated. These results can help design LSC systems that are more efficient in terms of light collection.

  1. Material degradation of liquid organic semiconductors analyzed by nuclear magnetic resonance spectroscopy

    SciTech Connect

    Fukushima, Tatsuya; Yamamoto, Junichi; Fukuchi, Masashi; Kaji, Hironori; Hirata, Shuzo; Jung, Heo Hyo; Adachi, Chihaya; Hirata, Osamu; Shibano, Yuki

    2015-08-15

    Liquid organic light-emitting diodes (liquid OLEDs) are unique devices consisting only of liquid organic semiconductors in the active layer, and the device performances have been investigated recently. However, the device degradation, especially, the origin has been unknown. In this study, we show that material degradation occurs in liquid OLEDs, whose active layer is composed of carbazole with an ethylene glycol chain. Nuclear magnetic resonance (NMR) experiments clearly exhibit that the dimerization reaction of carbazole moiety occurs in the liquid OLEDs during driving the devices. In contrast, cleavages of the ethylene glycol chain are not detected within experimental error. The dimerization reaction is considered to be related to the device degradation.

  2. Non-Carbon Dyes For Platic Scintillators- Report

    SciTech Connect

    Teprovich, J.; Colon-Mercado, H.; Gaillard, J.; Sexton, L.; Washington, A.; Ward, P.; Velten, J.

    2015-10-19

    Scintillation based detectors are desirable for many radiation detection applications (portal and border monitoring, safeguards verification, contamination detection and monitoring). The development of next generation scintillators will require improved detection sensitivity for weak gamma ray sources, and fast and thermal neutron quantification. Radiation detection of gamma and neutron sources can be accomplished with organic scintillators, however, the single crystals are difficult to grow for large area detectors and subject to cracking. Alternatives to single crystal organic scintillators are plastic scintillators (PS) which offer the ability to be shaped and scaled up to produce large sized detectors. PS is also more robust than the typical organic scintillator and are ideally suited for deployment in harsh real-world environments. PS contain a mixture of dyes to down-convert incident radiation into visible light that can be detected by a PMT. This project will evaluate the potential use of nano-carbon dyes in plastic scintillators.

  3. Effects of electrolytes and polarity of organic liquids on the coalescence of droplets at aqueous-organic interfaces

    NASA Astrophysics Data System (ADS)

    Chen, Chao-Tai; Maa, Jer-Ru; Yang, Yu-Min; Chang, Chien-Hsiang

    1998-05-01

    The coalescence rate of aqueous droplets in organic media was studied experimentally. The effects of electrolytes with cations and anions of various valencies, and organic liquids of different polarities were investigated, and the results were compared with coalescence rate data of organic droplets in aqueous media of previous authors. It was found that for the cases of polar organic liquids, the effects of dissolved electrolytes on the coalescence of aqueous droplets in organic media was just the opposite to that of organic droplets in aqueous media. The coalescence rates of aqueous droplets increase and those of organic droplets decrease with the increase of electrolyte concentrations, but in the case of methyl isobutyl ketone, electrolytes of trivalent cations or anions, such as AlCl 3, LaCl 3, FeCl 3 and Na 3P0 4, increase the coalescence rates of aqueous droplets and reduce those of organic droplets strongly only within certain concentration ranges. Their effects are not nearly as pronounced outside these ranges. For the case of nonpolar organic liquids, dissolved electrolytes give no significant effect on the coalescence rates of either aqueous or organic droplets. The effects of electrolytes on the coalescence processes of liquid droplets is not significantly related to the bulk viscosity of the film liquids and the interfacial properties between the phases. It is more likely that these effects are caused by the change of intermolecular forces due to the addition of the electrolytes.

  4. Determination of optimal ionic liquid for organic single-crystal field-effect transistors

    NASA Astrophysics Data System (ADS)

    Ono, S.; Miwa, K.; Seki, S.

    2016-02-01

    We investigate organic single-crystal field-effect transistors with various ionic liquids as gate dielectric. We find that the mobility of the field-effect transistors for both p-type and n-type organic semiconductors increases with decreasing total capacitance of the ionic liquid. However, it does not depend on the ion species at the interface between the organic semiconductor and the ionic liquid. By choosing an appropriate ionic liquid, a high carrier mobility of 12.4 cm2/V s in rubrene single crystals (p-type) and 0.13 cm2/V s in 7.7.8.8-Tetracyanoquinodimethane single crystals (n-type) are achieved. This study clarifies the influence of ionic liquids on the device performance of organic field-effect transistors and shows a way to maximize carrier mobility at the solid/liquid interface.

  5. Multiwalled carbon nanotubes sensor for organic liquid detection at room temperature

    NASA Astrophysics Data System (ADS)

    Chaudhary, Deepti; Khare, Neeraj; Vankar, V. D.

    2016-04-01

    We have explored the possibility of using multiwalled carbon nanotubes (MWCNTs) as room temperature chemical sensor for the detection of organic liquids such as ethanol, propanol, methanol and toluene. MWCNTs were synthesized by thermal chemical vapor deposition (TCVD) technique. The interdigitated electrodes were fabricated by conventional photolithography technique. The sensor was fabricated by drop depositing MWCNT suspension onto the interdigitated electrodes. The sensing properties of MWCNTs sensor was studied for organic liquids detection. The resistance of sensor was found to increase upon exposure to these liquids. Sensor shows good reversibility and fast response at room temperature. Charge transfer between the organic liquid and sensing element is the dominant sensing mechanism.

  6. Calculation of heat conductivity of organic liquids as function of temperature

    SciTech Connect

    Safarov, M.M.; Khadzhidov, Kh.

    1995-12-01

    Results of generalization of experimental data on heat conductivity of a series of organic liquids as a function of temperature at atmospheric pressure are presented. The approximation dependence for calculation of heat conductivity of liquid organic compounds as a function of temperature, normal boiling temperature, and molar mass is obtained.

  7. Tertiary phase diagram of cellulose, ionic liquid and organic solvent

    NASA Astrophysics Data System (ADS)

    Zhang, Xin; Henderson, Doug; Tyagi, Madhusudan; Mao, Yimin; Briber, Robert M.; Wang, Howard

    Cellulose is the most abundant natural polymer on earth, and widely used in products from clothing to paper. Fundamental understanding of molecular solutions of cellulose is the key to realize advanced technologies beyond cellulose fibers. It has been reported that certain ionic liquid/organic solvent mixtures dissolve cellulose. In this study, the tertiary phase diagram of microcrystalline cellulose, 1-Ethyl-3-methylimidazolium acetate (EMIMAc), and dimethylformamide (DMF) mixtures has been determined using optical cloud point method and small angle neutron scattering (SANS). Data indicate that a molar ratio of EMIMAc to cellulose repeating unit equal or greater than 3 is necessary but not sufficient in forming one-phase homogeneous solutions. A miscibility gap exists in the dilute regime, where a minimum of 5 mol% of EMIM Ac in DMF is needed to form homogenous solutions. SANS show that cellulose chains adopt Gaussian-like conformation in homogenous solutions. The solutions exhibit the characteristics of upper critical solution temperature. Clustering of cellulose chains occurs at low EMIMAc/DMF or EMIMAc/cellulose ratio, or at low temperatures. The mechanism of cellulose dissolution in tertiary mixture is discussed.

  8. Mass flow of a volatile organic liquid mixture in soils

    SciTech Connect

    Gerstl, Z.; Galin, Ts.; Yaron, B.

    1994-05-01

    The flow of kerosene, a volatile organic liquid mixture (VOLM), was studied in loam and clay soils and in a medium sand. The kerosene residual capacity and conductivity were determined for all three media at different initial moisture contents and with kerosene of different compositions. The kerosene conductivity of the soil was found to be strongly influenced by the soil texture and initial moisture content as well as by the kerosene composition. The kerosene conductivity of the sand was two orders of magnitude greater than that of the soils and was unaffected by initial moisture contents as high as field capacity. The kerosene conductivity of the loam soil was similar in oven dry and air dry soils, but increased significantly in soils at 70% and fun field capacity due to the Yuster effect. In the clay soil the kerosene conductivity of the air dry sod was four times that of the oven dry sod and increased somewhat in the soil at 70% field capacity. No kerosene flow was observed in the oven dry soil at full field capacity. The differences in kerosene conductivity in these soils and the effect of moisture content were attributed to the different pore-sin distributions of the soil& Changes in the composition of the kerosene due to volatilization of the light fractions resulted in increased viscosity of the residual kerosene. This increased viscosity affected the fluid properties of kerosene, which resulted in decreased kerosene conductivity in the sand and the soils. 29 refs., 4 figs., 4 tabs.

  9. Development of polyatomic ion beam system using liquid organic materials

    NASA Astrophysics Data System (ADS)

    Takaoka, G. H.; Nishida, Y.; Yamamoto, T.; Kawashita, M.

    2005-08-01

    We have developed a new type of polyatomic ion beam system using liquid organic materials such as octane and ethanol, which consists of a capillary type of nozzle, an ionizer, a mass-separator and a substrate holder. Ion current extracted after ionization was 430 μA for octane and 200 μA for ethanol, respectively. The mass-analysis was realized using a compact E × B mass filter, and the mass-analyzed ion beams were transferred toward the substrate. The ion current density at the substrate was a few μA/cm2 for the mass-separated ion species. Interactions of polyatomic ion beams with silicon (Si) surfaces were investigated by utilizing the ellipsometry measurement. It was found that the damaged layer thickness irradiated by the polyatomic ions with a mass number of about 40 was smaller than that by Ar ion irradiation at the same incident energy and ion fluence. The result indicated that the rupture of polyatomic ions occurred upon its impact on the Si surface with an incident energy larger than a few keV. In addition, the chemical modification of Si surfaces such as wettability could be achieved by adjusting the incident energy for the ethanol ions, which included all the fragment ions.

  10. Separation of scintillation and Cherenkov lights in linear alkyl benzene

    NASA Astrophysics Data System (ADS)

    Li, Mohan; Guo, Ziyi; Yeh, Minfang; Wang, Zhe; Chen, Shaomin

    2016-09-01

    To separate scintillation and Cherenkov lights in water-based liquid scintillator detectors is a desired feature for future neutrino and proton decay experiments. Linear alkyl benzene (LAB) is one important ingredient of a water-based liquid scintillator currently under development. In this paper we report on the separation of scintillation and Cherenkov lights observed in an LAB sample. The rise and decay times of the scintillation light are measured to be (7.7 ± 3.0) ns and (36.6 ± 2.4) ns , respectively, while the full width [-3σ, 3σ] of the Cherenkov light is 12 ns and is dominated by the time resolution of the photomultiplier tubes. The scintillation light yield was measured to be (1.01 ± 0.12) ×103 photons / MeV .

  11. Investigation of the Extinguishing Features for Liquid Fuels and Organic Flammable Liquids Atomized by a Water Flow

    NASA Astrophysics Data System (ADS)

    Voytkov, Ivan V.; Zabelin, Maksim V.; Vysokomornaya, Olga V.

    2016-02-01

    The processes of heat and mass transfer were investigated experimentally while moving and evaporating the atomized water flow in high-temperature combustion products of typical liquid fuels and organic flammable liquids: gasoline, kerosene, acetone, crude oil, industrial alcohol. We determined typical periods of liquid extinguishing by an atomized water flow of various dispersability. Data of the discharge of extinguishing medium corresponding to various parameters of atomization and duration of using the atomization devices was presented. It is shown that Um≈3.5 m/s is a minimal outflow velocity of droplets during moving while passing the distance of 1m in the high-temperature gas medium to stop the combustion of organic liquids.

  12. Ionic Liquid Structure-Induced Effects on Organic Reactions

    NASA Astrophysics Data System (ADS)

    Stark, Annegret

    Understanding the ways in which the constituents of ionic liquids, i.e. the type of cation, its substitution, and the type of anion chosen, interact with reactants is prerequisite to deliberately designing an ionic liquid solvent with optimum performance. Several approaches, including physico-chemical and spectroscopic measurements and computational studies of binary ionic liquid-substrate mixtures have been presented that investigate the strength of interactions.

  13. Scintillators and applications thereof

    DOEpatents

    Williams, Richard T.

    2014-07-15

    Scintillators of various constructions and methods of making and using the same are provided. In some embodiments, a scintillator comprises at least one radiation absorption region and at least one spatially discrete radiative exciton recombination region.

  14. Scintillators and applications thereof

    SciTech Connect

    Williams, Richard T.

    2015-09-01

    Scintillators of various constructions and methods of making and using the same are provided. In some embodiments, a scintillator comprises at least one radiation absorption region and at least one spatially discrete radiative exciton recombination region.

  15. SNO+ Scintillator Purification and Assay

    SciTech Connect

    Ford, R.; Vazquez-Jauregui, E.; Chen, M.; Chkvorets, O.; Hallman, D.

    2011-04-27

    We describe the R and D on the scintillator purification and assay methods and technology for the SNO+ neutrino and double-beta decay experiment. The SNO+ experiment is a replacement of the SNO heavy water with liquid scintillator comprised of 2 g/L PPO in linear alkylbenzene (LAB). During filling the LAB will be transported underground by rail car and purified by multi-stage distillation and steam stripping at a flow rate of 19 LPM. While the detector is operational the scintillator can be recirculated at 150 LPM (full detector volume in 4 days) to provide repurification as necessary by either water extraction (for Ra, K, Bi) or by functional metal scavenger columns (for Pb, Ra, Bi, Ac, Th) followed by steam stripping to remove noble gases and oxygen (Rn, O{sub 2}, Kr, Ar). The metal scavenger columns also provide a method for scintillator assay for ex-situ measurement of the U and Th chain radioactivity. We have developed ''natural'' radioactive spikes of Pb and Ra in LAB and use these for purification testing. Lastly, we present the planned operating modes and purification strategies and the plant specifications and design.

  16. SNO+ Scintillator Purification and Assay

    NASA Astrophysics Data System (ADS)

    Ford, R.; Chen, M.; Chkvorets, O.; Hallman, D.; Vázquez-Jáuregui, E.

    2011-04-01

    We describe the R&D on the scintillator purification and assay methods and technology for the SNO+ neutrino and double-beta decay experiment. The SNO+ experiment is a replacement of the SNO heavy water with liquid scintillator comprised of 2 g/L PPO in linear alkylbenzene (LAB). During filling the LAB will be transported underground by rail car and purified by multi-stage distillation and steam stripping at a flow rate of 19 LPM. While the detector is operational the scintillator can be recirculated at 150 LPM (full detector volume in 4 days) to provide repurification as necessary by either water extraction (for Ra, K, Bi) or by functional metal scavenger columns (for Pb, Ra, Bi, Ac, Th) followed by steam stripping to remove noble gases and oxygen (Rn, O2, Kr, Ar). The metal scavenger columns also provide a method for scintillator assay for ex-situ measurement of the U and Th chain radioactivity. We have developed "natural" radioactive spikes of Pb and Ra in LAB and use these for purification testing. Lastly, we present the planned operating modes and purification strategies and the plant specifications and design.

  17. Molecular model of self diffusion in polar organic liquids: implications for conductivity and fluidity in polar organic liquids and electrolytes.

    PubMed

    Frech, Roger; Petrowsky, Matt

    2014-03-01

    Decades of studying isothermal and temperature-dependent mass and charge transport in polar organic liquids and electrolytes have resulted in two mutually incompatible models and the failure to develop a general molecular level picture. The hydrodynamic model describes conductivity, diffusion, and dielectric relaxation in terms of viscosity, while the inadequacy of the thermal activation model leads to empirical descriptions and fitting procedures whose adjustable parameters have little or no physical significance. We recently demonstrated that transport data can be characterized with a high degree of accuracy and self-consistency using the compensated Arrhenius formalism (CAF), where the transport property of interest assumes an Arrhenius-like form that also includes a dielectric constant dependence in the exponential prefactor. Here, we provide the molecular-level basis for the CAF by first modifying transition state theory, emphasizing the coupling of the diffusing molecule's motion with the dynamical motion of the surrounding matrix. We then explicitly include the polarization energy contribution from the dipolar medium. The polarization energy is related to molecular and system properties through the dipole moment and dipole density, respectively. The energy barrier for transport is coupled to the polarization energy, and we show that accounting for the role of the polarization energy leads naturally to the dielectric constant dependence in the exponential prefactor. PMID:24559237

  18. Surface Tension of Organic Liquids Using the OPLS/AA Force Field.

    PubMed

    Zubillaga, Rafael A; Labastida, Ariana; Cruz, Bibiana; Martínez, Juan Carlos; Sánchez, Enrique; Alejandre, José

    2013-03-12

    Molecular dynamics simulations are performed to obtain the surface tension of 61 organic liquids using the OPLS/AA (all-atom optimized potential for liquid simulations). The force field parameters are the same as those recently used (Caleman et al. J. Chem. Theory Comput.2012, 8, 61) to determine several thermodynamic properties of 146 organic liquids. The correct evaluation of surface tension using slab simulations of liquids requires one to properly take into account the long-range interactions (Trukhymchuk and Alejandre J. Chem. Phys.1999, 111, 8510). In addition, the liquid density from slab simulations has to be the same as that obtained in liquid simulations at constant temperature and pressure. The new results of surface tensions from this work improve those reported by Caleman et al. The OPLS/AA force field gives good surface tensions compared with experimental data for most of the systems studied in this work, although it was developed to simulate liquids. PMID:26587622

  19. Method and apparatus for the removal or bioconversion of constituents of organic liquids

    DOEpatents

    Scott, T.; Scott, C.D.

    1994-10-25

    A method and apparatus are disclosed for the removal or conversion of constituents from bulk organic liquids. A countercurrent biphasic bioreactor system is utilized to disperse and recoalesce a biocatalyst contained in the aqueous liquid phase into the organic liquid phase containing the constituent. Two transient, high-intensity electrical fields rupture the aqueous drops into a plurality of microdroplets and induce continuous coalescence and redispersion as the microdroplets travel through the organic phase, thus increasing surface area. As the aqueous microdroplets progress through the organic phase, the biocatalyst then reacts with the constituent to produce a product which is then removed from the bioreactor in the aqueous phase or retained in the organic phase. The organic liquid, now free of the original constituents, is ready for immediate use or further processing. 1 fig.

  20. Method and apparatus for the removal of bioconversion of constituents of organic liquids

    DOEpatents

    Scott, Timothy; Scott, Charles D.

    1994-01-01

    A method and apparatus for the removal or conversion of constituents from bulk organic liquids. A countercurrent biphasic bioreactor system is utilized to disperse and recoalesce a biocatalyst contained in the aqueous liquid phase into the organic liquid phase containing the constituent. Two transient, high-intensity electrical fields rupture the aqueous drops into a plurality of microdroplets and induce continuous coalescence and redispersion as the microdroplets travel through the organic phase, thus increasing surface area. As the aqueous microdroplets progress through the organic phase, the biocatalyst then reacts with the constituent to produce a product which is then removed from the bioreactor in the aqueous phase or retained in the organic phase. The organic liquid, now free of the original constituents, is ready for immediate use or further processing.

  1. Lead carbonate scintillator materials

    DOEpatents

    Derenzo, Stephen E.; Moses, William W.

    1991-01-01

    Improved radiation detectors containing lead carbonate or basic lead carbonate as the scintillator element are disclosed. Both of these scintillators have been found to provide a balance of good stopping power, high light yield and short decay constant that is superior to other known scintillator materials. The radiation detectors disclosed are favorably suited for use in general purpose detection and in medical uses.

  2. Scintillator materials for calorimetry

    SciTech Connect

    Weber, M.J.

    1994-09-01

    Requirements for fast, dense scintillator materials for calorimetry in high energy physics and approaches to satisfying these requirements are reviewed with respect to possible hosts and luminescent species. Special attention is given to cerium-activated crystals, core-valence luminescence, and glass scintillators. The present state of the art, limitations, and suggestions for possible new scintillator materials are presented.

  3. Scintillator manufacture at Fermilab

    SciTech Connect

    Mellott, K.; Bross, A.; Pla-Dalmau, A.

    1998-08-01

    A decade of research into plastic scintillation materials at Fermilab is reviewed. Early work with plastic optical fiber fabrication is revisited and recent experiments with large-scale commercial methods for production of bulk scintillator are discussed. Costs for various forms of scintillator are examined and new development goals including cost reduction methods and quality improvement techniques are suggested.

  4. Inorganic or organic azide-containing hypergolic ionic liquids.

    PubMed

    Joo, Young-Hyuk; Gao, Haixiang; Zhang, Yanqiang; Shreeve, Jean'ne M

    2010-04-01

    Recently extensive research has focused on replacing toxic hydrazine, monomethylhydrazine, and unsymmetrical dimethylhydrazine as liquid propellant fuels. 2-Azido-N,N-dimethylethylamine (1) is a good candidate to replace hydrazine derivatives in certain hypergolic fuel applications. Energetic ionic liquids that contain the 2-azido-N,N,N-trimethylethylammonium cation with nitrocyanamide, dicyanamide, dinitramide, or azide anion have been successfully synthesized in good yields by metathesis reactions. Ionic liquids have received considerable attention as energetic materials. The replacement of hydrazine with tertiary ammonium salts is especially attractive since many ionic liquids are models for green chemistry. In this work, new azide-functionalized ionic liquids are demonstrated to exhibit hypergolic activity with such oxidizers as 100% nitric acid or nitrogen tetraoxide (NTO). PMID:20175509

  5. Deuterated-xylene (EJ301D): A new, improved deuterated scintillator for neutron spectroscopy

    NASA Astrophysics Data System (ADS)

    Becchetti, Fred; Torres-Isea, Ramon; Febbraro, Michael; Clarke, Shaun; di Fulvio, Angela; Pozzi, Sara

    2015-10-01

    In conjunction with Eljen Technologies (Sweetwater,TX), we have developed and evaluated a deuterated-xylene based liquid organic scintillator detector (3 in. × 3 in.) and PMT assembly. Like deuterated-benzene based scintillators such as EJ315 and NE230 the n +d recoil spectrum producing the light spectrum has distinct peaks corresponding to specific neutron energy groups. The light spectrum can then be unfolded to produce neutron energy spectra including fission spectra without the need for time-of-flight. This results in a large over-all detection efficiency for such detectors as they can be used in arrays covering a large angular range, close to the neutron source and do not require a pulsed or gated source. In addition, the new EJ301D scintillator has a lower neutron energy threshold for improved PSD, which is important in many low-energy measurements. More importantly this scintillator has a much safer flash point than benzene-based scintillators making it better suited for many applications including field applications in nuclear security and non-proliferation. Work supported in part by US NSF and by the Consortium for Verification Technology under Department of Energy National Nuclear Security Administration Award Number DE-NA0002534.

  6. The XENON100 Dark Matter Experiment: Design, Construction, Calibration and 2010 Search Results with Improved Measurement of the Scintillation Response of Liquid Xenon to Low-Energy Nuclear Recoils

    NASA Astrophysics Data System (ADS)

    Plante, Guillaume

    An impressive array of astrophysical observations suggest that 83% of the matter in the universe is in a form of non-luminous, cold, collisionless, non-baryonic dark matter. Several extensions of the Standard Model of particle physics aimed at solving the hierarchy problem predict stable weakly interacting massive particles (WIMPs) that could naturally have the right cosmological relic abundance today to compose most of the dark matter if their interactions with normal matter are on the order of a weak scale cross section. These candidates also have the added benefit that their properties and interaction rates can be computed in a well defined particle physics model. A considerable experimental effort is currently under way to uncover the nature of dark matter. One method of detecting WIMP dark matter is to look for its interactions in terrestrial detectors where it is expected to scatter off nuclei. In 2007, the XENON10 experiment took the lead over the most sensitive direct detection dark matter search in operation, the CDMS II experiment, by probing spin-independent WIMP-nucleon interaction cross sections down to sigmachi N ˜ 5 x 10-44 cm 2 at 30 GeV/c2. Liquefied noble gas detectors are now among the technologies at the forefront of direct detection experiments. Liquid xenon (LXe), in particular, is a well suited target for WIMP direct detection. It is easily scalable to larger target masses, allows discrimination between nuclear recoils and electronic recoils, and has an excellent stopping power to shield against external backgrounds. A particle losing energy in LXe creates both ionization electrons and scintillation light. In a dual-phase LXe time projection chamber (TPC) the ionization electrons are drifted and extracted into the gas phase where they are accelerated to amplify the charge signal into a proportional scintillation signal. These two signals allow the three-dimensional localization of events with millimeter precision and the ability to

  7. Designing Electronics and PMT Housing for a Liquid Scintillation Detector to be Used for Measuring Muon-Induced Processes at Homestake

    NASA Astrophysics Data System (ADS)

    Woltman, Brian; Davis, Patrick; Mei, Dongming; Zhang, Chao

    2010-02-01

    Understanding the backgrounds produced by muon-induced processes is important to the success of experiments searching for rare event physics such as neutrinoless double-beta decay, dark matter, or neutrino oscillations, which require extremely low backgrounds. Measuring these muon-induced processes is vital for the low background experiments planned for the Sanford Lab. We have designed a detector to measure the muon-induced backgrounds produced underground. Our detector consists of a 10.8 liter scintillator joined with two PMT's. We will present our design for housing the PMT's, including their attachment to the scintillator and necessary magnetic shielding. We will also present our design for a voltage divider that was constructed and tested for use on the PMT's. )

  8. Designing Electronics and PMT Housing for a Liquid Scintillator Detector to be Used for Measuring Muon-Induced Processes at Homestake

    NASA Astrophysics Data System (ADS)

    Woltman, Brian; Davis, Patrick; Mei, Dongming; Zhang, Chao

    2009-10-01

    Understanding the backgrounds produced by muon-induced processes is important to the success of experiments searching for rare event physics such as neutrinoless double-beta decay, dark matter, or neutrino oscillations, which require extremely low backgrounds. Measuring these muon-induced processes is vital for the low background experiments planned for the Sanford Lab. We have designed a detector to measure the muon-induced backgrounds produced underground. Our detector consists of a 10.8 liter scintillator joined with two PMT's. We will present our design for housing the PMT's, including their attachment to the scintillator and necessary magnetic shielding. We will also present our design for a voltage divider that was constructed and tested for use on each of the PMT's.

  9. Partition coefficients of organic compounds in new imidazolium based ionic liquids using inverse gas chromatography.

    PubMed

    Revelli, Anne-Laure; Mutelet, Fabrice; Jaubert, Jean-Noël

    2009-06-01

    Partition coefficients of organic compounds in four ionic liquids: 1-ethanol-3-methylimidazolium tetrafluoroborate, 1-ethanol-3-methylimidazolium hexafluorophosphate, 1,3-dimethylimidazolium dimethylphosphate and 1-ethyl-3-methylimidazolium diethylphosphate were measured using inverse gas chromatography from 303.3 to 332.55K. The influence of gas-liquid and gas-solid interfacial adsorption of different solutes on ionic liquids was also studied. Most of the polar solutes were retained largely by partition while light hydrocarbons were retained predominantly by interfacial adsorption on the ionic liquids studied in this work. The solvation characteristics of the ionic liquids were evaluated using the Abraham solvation parameter model. PMID:19414174

  10. Scintillator reflective layer coextrusion

    SciTech Connect

    Yun, Jae-Chul; Para, Adam

    2001-01-01

    A polymeric scintillator has a reflective layer adhered to the exterior surface thereof. The reflective layer comprises a reflective pigment and an adhesive binder. The adhesive binder includes polymeric material from which the scintillator is formed. A method of forming the polymeric scintillator having a reflective layer adhered to the exterior surface thereof is also provided. The method includes the steps of (a) extruding an inner core member from a first amount of polymeric scintillator material, and (b) coextruding an outer reflective layer on the exterior surface of the inner core member. The outer reflective layer comprises a reflective pigment and a second amount of the polymeric scintillator material.

  11. General nature of liquid-liquid transition in aqueous organic solutions

    NASA Astrophysics Data System (ADS)

    Murata, Ken-Ichiro; Tanaka, Hajime

    2013-11-01

    The presence or absence of a liquid-liquid transition in water is one of the hot topics in liquid science, and while a liquid-liquid transition in water/glycerol mixtures is known, its generality in aqueous solutions has remained elusive. Here we reveal that 14 aqueous solutions of sugar and polyol molecules, which have an ability to form hydrogen bonding with water molecules, exhibit liquid-liquid transitions. We find evidence that both melting of ice and liquid-liquid transitions in all these aqueous solutions are controlled solely by water activity, which is related to the difference in the chemical potential between an aqueous solution and pure water at the same temperature and pressure. Our theory shows that water activity is determined by the degree of local tetrahedral ordering, indicating that both phenomena are driven by structural ordering towards ice-like local structures. This has a significant implication on our understanding of the low-temperature behaviour of water.

  12. Properties of scintillator solutes

    SciTech Connect

    Fluornoy, J.M.

    1998-06-01

    This special report summarizes measurements of the spectroscopic and other properties of the solutes that were used in the preparation of several new liquid scintillators developed at EG and G/Energy Measurements/Santa Barbara Operations (the precursor to Bechtel Nevada/Special Technologies Laboratory) on the radiation-to-light converter program. The data on the individual compounds are presented in a form similar to that used by Prof. Isadore Berlman in his classic handbook of fluorescence spectra. The temporal properties and relative efficiencies of the new scintillators are presented in Table 1, and the efficiencies as a function of wavelength are presented graphically in Figure 1. In addition, there is a descriptive glossary of the abbreviations used herein. Figure 2 illustrates the basic structures of some of the compounds and of the four solvents reported in this summary. The emission spectra generally exhibit more structure than the absorption spectra, with the result that the peak emission wavelength for a given compound may lie several nm away from the wavelength, {lambda}{sub avg}, at the geometric center of the emission spectrum. Therefore, the author has chosen to list absorption peaks, {lambda}{sub max}, and emission {lambda}{sub avg} values in Figures 3--30, as being most illustrative of the differences between the compounds. The compounds, BHTP, BTPB, ADBT, and DPTPB were all developed on this program. P-terphenyl, PBD, and TPB are commercially available blue emitters. C-480 and the other longer-wavelength emitters are laser dyes available commercially from Exciton Corporation. 1 ref., 30 figs.

  13. Composite solid-state scintillators for neutron detection

    DOEpatents

    Dai, Sheng; Im, Hee-Jung; Pawel, Michelle D.

    2006-09-12

    Applicant's present invention is a composite scintillator for neutron detection comprising a matrix material fabricated from an inorganic sol-gel precursor solution homogeneously doped with a liquid scintillating material and a neutron absorbing material. The neutron absorbing material yields at least one of an electron, a proton, a triton, an alpha particle or a fission fragment when the neutron absorbing material absorbs a neutron. The composite scintillator further comprises a liquid scintillating material in a self-assembled micelle formation homogeneously doped in the matrix material through the formation of surfactant-silica composites. The scintillating material is provided to scintillate when traversed by at least one of an electron, a proton, a triton, an alpha particle or a fission fragment. The scintillating material is configured such that the matrix material surrounds the micelle formation of the scintillating material. The composite scintillator is fabricated and applied as a thin film on substrate surfaces, a coating on optical fibers or as a glass material.

  14. Strongly Dichroic Organic Films via Controlled Assembly of Modular Aromatic Charge-Transfer Liquid Crystals.

    PubMed

    Bé, Ariana Gray; Tran, Cheryl; Sechrist, Riley; Reczek, Joseph J

    2015-10-01

    The formation of highly anisotropic organic thin films based on the designed self-assembly of mixed-stack liquid crystals is reported. A series of alkoxyanthracene donors is combined in a modular fashion with a naphthalenediimide acceptor to generate new charge-transfer columnar liquid crystals. Materials characterization and molecular modeling provides insight into structure-function relationships in these organic materials that lead to the striking bulk dichroic properties of certain molecular assemblies. PMID:26375256

  15. Using FT-IR Spectroscopy to Measure Charge Organization in Ionic Liquids

    PubMed Central

    Burba, Christopher M.; Janzen, Jonathan; Butson, Eric D.; Coltrain, Gage L.

    2013-01-01

    A major goal in the field of ionic liquids is correlating transport property trends with the underlying liquid structure of the compounds, such as the degree of charge organization among the constituent ions. Traditional techniques for experimentally assessing charge organization are specialized and not readily available for routine measurements. This represents a significant roadblock in elucidating these correlations. We use a combination of transmission and polarized-ATR infrared spectroscopy to measure the degree of charge organization for ionic liquids. The technique is illustrated with a family of 1-alkyl-3-methylimidazolium trifluoromethansulfonate ionic liquids at 30°C. As expected, the amount of charge organization decreases as the alkyl side chain is lengthened, highlighting the important role of short-range repulsive interactions in defining quasilattice structure. Inherent limitations of the method are identified and discussed. The quantitative measurements of charge organization are then correlated with trends in the transport properties of the compounds to highlight the relationship between charge and momentum transport and the underlying liquid structure. Most research laboratories possess infrared spectrometers capable of conducting these measurements, thus, the proposed method may represent a cost-effective solution for routinely measuring charge organization in ionic liquids. PMID:23781877

  16. Infrared spectra of organic liquids and cluster model of substance

    NASA Astrophysics Data System (ADS)

    Verveyko, Vyacheslav N.; Verveyko, Marina V.; Melnikov, Gennady A.

    2016-03-01

    We consider the effective field theory based on the consideration of the rotation and libration of molecules in surroundings represented as effective clusters. The suitable distribution function with respect to the number of particles, which form a cluster, is discussed. This approach is applied to the forecasting of infrared spectrum frequencies of liquids using liquefied inert gases, nitrogen, oxygen, benzene and water as examples.

  17. Modeling the gas-particle partitioning of secondary organic aerosol: the importance of liquid-liquid phase separation

    NASA Astrophysics Data System (ADS)

    Zuend, A.; Seinfeld, J. H.

    2012-01-01

    The partitioning of semivolatile organic compounds between the gas phase and aerosol particles is an important source of secondary organic aerosol (SOA). Gas-particle partitioning of organic and inorganic species is influenced by the physical state and water content of aerosols, and therefore ambient relative humidity (RH), as well as temperature and organic loading levels. We introduce a novel combination of the thermodynamic models AIOMFAC (for liquid mixture non-ideality) and EVAPORATION (for pure compound vapor pressures) with oxidation product information from the Master Chemical Mechanism (MCM) for the computation of gas-particle partitioning of organic compounds and water. The presence and impact of a liquid-liquid phase separation in the condensed phase is calculated as a function of variations in relative humidity, organic loading levels, and associated changes in aerosol composition. We show that a complex system of water, ammonium sulfate, and SOA from the ozonolysis of α-pinene exhibits liquid-liquid phase separation over a wide range of relative humidities (simulated from 30% to 99% RH). Since fully coupled phase separation and gas-particle partitioning calculations are computationally expensive, different simplified model approaches are tested with regards to computational costs and accuracy of predictions compared to the benchmark calculation. Both forcing a liquid one-phase aerosol considering non-ideal mixing or assuming an ideal mixture bear the potential for vastly incorrect partitioning predictions. Assuming an ideal mixture leads to substantial overestimation of the particulate organic mass, at high RH by more than 200%. Moreover, the simplified one-phase cases stress two key points for accurate gas-particle partitioning calculations: (1) non-ideality in the condensed phase needs to be considered and (2) liquid-liquid phase separation is a consequence of considerable deviations from ideal mixing in solutions containing inorganic ions and

  18. Modeling the gas-particle partitioning of secondary organic aerosol: the importance of liquid-liquid phase separation

    NASA Astrophysics Data System (ADS)

    Zuend, A.; Seinfeld, J. H.

    2012-05-01

    The partitioning of semivolatile organic compounds between the gas phase and aerosol particles is an important source of secondary organic aerosol (SOA). Gas-particle partitioning of organic and inorganic species is influenced by the physical state and water content of aerosols, and therefore ambient relative humidity (RH), as well as temperature and organic loading levels. We introduce a novel combination of the thermodynamic models AIOMFAC (for liquid mixture non-ideality) and EVAPORATION (for pure compound vapor pressures) with oxidation product information from the Master Chemical Mechanism (MCM) for the computation of gas-particle partitioning of organic compounds and water. The presence and impact of a liquid-liquid phase separation in the condensed phase is calculated as a function of variations in relative humidity, organic loading levels, and associated changes in aerosol composition. We show that a complex system of water, ammonium sulfate, and SOA from the ozonolysis of α-pinene exhibits liquid-liquid phase separation over a wide range of relative humidities (simulated from 30% to 99% RH). Since fully coupled phase separation and gas-particle partitioning calculations are computationally expensive, several simplified model approaches are tested with regard to computational costs and accuracy of predictions compared to the benchmark calculation. It is shown that forcing a liquid one-phase aerosol with or without consideration of non-ideal mixing bears the potential for vastly incorrect partitioning predictions. Assuming an ideal mixture leads to substantial overestimation of the particulate organic mass, by more than 100% at RH values of 80% and by more than 200% at RH values of 95%. Moreover, the simplified one-phase cases stress two key points for accurate gas-particle partitioning calculations: (1) non-ideality in the condensed phase needs to be considered and (2) liquid-liquid phase separation is a consequence of considerable deviations from ideal

  19. Chemical reactions of metal powders with organic and inorganic liquids during ball milling

    NASA Technical Reports Server (NTRS)

    Arias, A.

    1975-01-01

    Chromium and/or nickel powders were milled in metal chlorides and in organic liquids representative of various functional groups. The powders always reacted with the liquid and became contaminated with elements from them. The milled powders had specific surface areas ranging from 0.14 to 37 sq m/g, and the total contamination with elements from the milling liquid ranged from 0.01 to 56 weight percent. Compounds resulting from substitution, addition, or elimination reactions formed in or from the milling liquid.

  20. Shifting scintillator neutron detector

    SciTech Connect

    Clonts, Lloyd G; Cooper, Ronald G; Crow, Jr., Morris Lowell; Hannah, Bruce W; Hodges, Jason P; Richards, John D; Riedel, Richard A

    2014-03-04

    Provided are sensors and methods for detecting thermal neutrons. Provided is an apparatus having a scintillator for absorbing a neutron, the scintillator having a back side for discharging a scintillation light of a first wavelength in response to the absorbed neutron, an array of wavelength-shifting fibers proximate to the back side of the scintillator for shifting the scintillation light of the first wavelength to light of a second wavelength, the wavelength-shifting fibers being disposed in a two-dimensional pattern and defining a plurality of scattering plane pixels where the wavelength-shifting fibers overlap, a plurality of photomultiplier tubes, in coded optical communication with the wavelength-shifting fibers, for converting the light of the second wavelength to an electronic signal, and a processor for processing the electronic signal to identify one of the plurality of scattering plane pixels as indicative of a position within the scintillator where the neutron was absorbed.

  1. Scintillator manufacture at Fermilab

    SciTech Connect

    Mellott, K.; Bross, A.; Pla-Dalmau, A.

    1998-11-01

    A decade of research into plastic scintillation materials at Fermilab is reviewed. Early work with plastic optical fiber fabrication is revisited and recent experiments with large-scale commercial methods for production of bulk scintillator are discussed. Costs for various forms of scintillator are examined and new development goals including cost reduction methods and quality improvement techniques are suggested. {copyright} {ital 1998 American Institute of Physics.}

  2. Lead carbonate scintillator materials

    DOEpatents

    Derenzo, S.E.; Moses, W.W.

    1991-05-14

    Improved radiation detectors containing lead carbonate or basic lead carbonate as the scintillator element are disclosed. Both of these scintillators have been found to provide a balance of good stopping power, high light yield and short decay constant that is superior to other known scintillator materials. The radiation detectors disclosed are favorably suited for use in general purpose detection and in medical uses. 3 figures.

  3. Extruded plastic scintillation detectors

    SciTech Connect

    Anna Pla-Dalmau, Alan D. Bross and Kerry L. Mellott

    1999-04-16

    As a way to lower the cost of plastic scintillation detectors, commercially available polystyrene pellets have been used in the production of scintillating materials that can be extruded into different profiles. The selection of the raw materials is discussed. Two techniques to add wavelength shifting dopants to polystyrene pellets and to extrude plastic scintillating strips are described. Data on light yield and transmittance measurements are presented.

  4. Study of equatorial scintillations

    NASA Technical Reports Server (NTRS)

    Pomalaza, J.; Woodman, R.; Tisnado, G.; Nakasone, E.

    1972-01-01

    Observations of the amplitude scintillations produced by the F-region in equatorial areas are presented. The equipment used for conducting the observations is described. The use of transmissions from the ATS-1, ATS-3, and ATS-5 for obtaining data is described. The two principal subjects discussed are: (1) correlation between satellite and incoherent radar observations of scintillations and (2) simultaneous observations of scintillations at 136 MHz and 1550 MHz.

  5. Temperature dependence of alpha-induced scintillation in the 1,1,4,4-tetraphenyl-1,3-butadiene wavelength shifter

    NASA Astrophysics Data System (ADS)

    Veloce, L. M.; Kuźniak, M.; Di Stefano, P. C. F.; Noble, A. J.; Boulay, M. G.; Nadeau, P.; Pollmann, T.; Clark, M.; Piquemal, M.; Schreiner, K.

    2016-06-01

    Liquid noble based particle detectors often use the organic wavelength shifter 1,1,4,4-tetraphenyl-1,3-butadiene (TPB) which shifts UV scintillation light to the visible regime, facilitating its detection, but which also can scintillate on its own. Dark matter searches based on this type of detector commonly rely on pulse-shape discrimination (PSD) for background mitigation. Alpha-induced scintillation therefore represents a possible background source in dark matter searches. The timing characteristics of this scintillation determine whether this background can be mitigated through PSD. We have therefore characterized the pulse shape and light yield of alpha induced TPB scintillation at temperatures ranging from 300 K down to 4 K, with special attention given to liquid noble gas temperatures. We find that the pulse shapes and light yield depend strongly on temperature. In addition, the significant contribution of long time constants above ~50 K provides an avenue for discrimination between alpha decay events in TPB and nuclear-recoil events in noble liquid detectors.

  6. Reverse osmosis molecular differentiation of organic liquids using carbon molecular sieve membranes.

    PubMed

    Koh, Dong-Yeun; McCool, Benjamin A; Deckman, Harry W; Lively, Ryan P

    2016-08-19

    Liquid-phase separations of similarly sized organic molecules using membranes is a major challenge for energy-intensive industrial separation processes. We created free-standing carbon molecular sieve membranes that translate the advantages of reverse osmosis for aqueous separations to the separation of organic liquids. Polymer precursors were cross-linked with a one-pot technique that protected the porous morphology of the membranes from thermally induced structural rearrangement during carbonization. Permeation studies using benzene derivatives whose kinetic diameters differ by less than an angstrom show kinetically selective organic liquid reverse osmosis. Ratios of single-component fluxes for para- and ortho-xylene exceeding 25 were observed and para- and ortho- liquid mixtures were efficiently separated, with an equimolar feed enriched to 81 mole % para-xylene, without phase change and at ambient temperature. PMID:27540170

  7. Method for monitoring the crystallization of an organic material from a liquid

    DOEpatents

    Asay, Blaine W.; Henson, Bryan F.; Sander, Robert K.; Robinson, Jeanne M.; Son, Steven F.; Dickson, Peter M.

    2004-10-05

    Method for monitoring the crystallization of at least one organic material from a liquid. According to the method, a liquid having at least one organic material capable of existing in at least one non-centrosymmetric phase is prepared. The liquid is interrogated with a laser beam at a chosen wavelength. As at least a portion of the at least one organic material crystallizes from the liquid, the intensity of any light scattered by the crystallized material at a wavelength equal to one-half the chosen wavelength of the interrogating laser beam is monitored. If the intensity of this scattered light, increases, then the crystals that form include at least one non-cetrosymmetric phase.

  8. Measurement and Estimation of Organic-Liquid/Water Interfacial Areas for Several Natural Porous Media

    SciTech Connect

    Brusseau, M.L.; Narter, M.; Schnaar, G.; Marble, J.

    2009-06-01

    The objective of this study was to quantitatively characterize the impact of porous-medium texture on interfacial area between immiscible organic liquid and water residing within natural porous media. Synchrotron X-ray microtomography was used to obtain high-resolution, three-dimensional images of solid and liquid phases in packed columns. The image data were processed to generate quantitative measurements of organic-liquid/water interfacial area and of organic-liquid blob sizes. Ten porous media, comprising a range of median grain sizes, grain-size distributions, and geochemical properties, were used to evaluate the impact of porous-medium texture on interfacial area. The results show that fluid-normalized specific interfacial area (A{sub f}) and maximum specific interfacial area (A{sub m}) correlate very well to inverse median grain diameter. These functionalities were shown to result from a linear relationship between effective organic-liquid blob diameter and median grain diameter. These results provide the basis for a simple method for estimating specific organic-liquid/water interfacial area as a function of fluid saturation for a given porous medium. The availability of a method for which the only parameter needed is the simple-to-measure median grain diameter should be of great utility for a variety of applications.

  9. THERMODYNAMIC MODELING OF LIQUID AEROSOLS CONTAINING DISSOLVED ORGANICS AND ELECTROLYTES

    EPA Science Inventory

    Many tropospheric aerosols contain large fractions of soluble organic material, believed to derive from the oxidation of precursors such alpha-pinene. The chemical composition of aerosol organic matter is complex and not yet fully understood.

    The key properties of solu...

  10. Vacuum Surface Science Meets Heterogeneous Catalysis: Dehydrogenation of a Liquid Organic Hydrogen Carrier in the Liquid State.

    PubMed

    Matsuda, Takashi; Taccardi, Nicola; Schwegler, Johannes; Wasserscheid, Peter; Steinrück, Hans-Peter; Maier, Florian

    2015-06-22

    Ultrahigh vacuum (UHV) surface science techniques are used to study the heterogeneous catalytic dehydrogenation of a liquid organic hydrogen carrier in its liquid state close to the conditions of real catalysis. For this purpose, perhydrocarbazole (PH), otherwise volatile under UHV, is covalently linked as functional group to an imidazolium cation, forming a non-volatile ionic liquid (IL). The catalysed dehydrogenation of the PH unit as a function of temperature is investigated for a Pt foil covered by a macroscopically thick PH-IL film and for Pd particles suspended in the PH-IL film, and for PH-IL on Au as inert support. X-ray photoelectron spectroscopy and thermal desorption spectroscopy allows us to follow in situ the catalysed transition of perhydrocarbazole to carbazole at technical reaction temperatures. The data demonstrate the crucial role of the Pt and Pd catalysts in order to shift the dehydrogenation temperature below the critical temperature of thermal decomposition. PMID:25891821

  11. Development of dispersive liquid-liquid microextraction based on solidification of floating organic drop for the determination of trace nickel.

    PubMed

    Wang, Yukun; Zhang, Jingwen; Zhao, Bin; Du, Xin; Ma, Jingjun; Li, Jingci

    2011-12-01

    A liquid-phase microextraction technique was developed using dispersive liquid-liquid microextraction based on solidification of floating organic drop combined with flame atomic absorption spectrometry, for the extraction and determination of trace amounts of nickel in water samples. Microextraction efficiency factors, such as the type and volume of extraction and dispersive solvents, pH, extraction time, the chelating agent amount, and ionic strength, were investigated and optimized. Under optimum conditions, the calibration graph was linear in the range of 4.23-250 μg L(-1) with a detection limit of 1.27 μg L(-1). The relative standard deviation for ten replicate measurements of 10 and 100 μg L(-1) of nickel were 3.21% and 2.55%, respectively. The proposed method was assessed through the analysis of certified reference water or recovery experiments. PMID:21598026

  12. Estimation of Interfacial Tension between Organic Liquid Mixtures and Water

    SciTech Connect

    Yoon, Hongkyu; Oostrom, Martinus; Werth, Charles J.

    2009-10-15

    Knowledge of IFT values for chemical mixtures helps guide the design and analysis of various processes, including NAPL remediation with surfactants or alcohol flushing, enhanced oil recovery, and chemical separation technologies, yet available literature values are sparse. A comprehensive comparison of thermodynamic and empirical models for estimating interfacial tension (IFT) of organic chemical mixtures with water is conducted, mainly focusing on chlorinated organic compounds for 14 ternary, three quaternary, and one quinary systems. Emphasis is placed on novel results for systems with three and four organic chemical compounds, and for systems with composite organic compounds like lard oil and mineral oil. Seven models are evaluated: the ideal and nonideal monolayer models (MLID and MLNID), the ideal and nonideal mutual solubility models (MSID and MSNID), an empirical model for ternary systems (EM), a linear mixing model based on mole fractions (LMMM), and a newly developed linear mixing model based on volume fractions of organic mixtures (LMMV) for higher order systems. The two ideal models (MLID and MSID) fit ternary systems of chlorinated organic compounds without surface active compounds relatively well. However, both ideal models did not perform well for the mixtures containing a surface active compound. However, for these systems, both the MLNID and MSNID models matched the IFT data well. It is shown that the MLNID model with a surface coverage value (0.00341 mmol/m2) obtained in this study can practically be used for chlorinated organic compounds. The LMMM results in poorer estimates of the IFT as the difference in IFT values of individual organic compounds in a mixture increases. The EM, with two fitting parameters, provided accurate results for all 14 ternary systems including composite organic compounds. The new LMMV method for quaternary and higher component systems was successfully tested. This study shows that the LMMV may be able to be used for

  13. Shear-Triggered Crystallization and Light Emission of a Thermally Stable Organic Supercooled Liquid

    PubMed Central

    2015-01-01

    Thermodynamics drive crystalline organic molecules to be crystallized at temperatures below their melting point. Even though molecules can form supercooled liquids by rapid cooling, crystalline organic materials readily undergo a phase transformation to an energetically favorable crystalline phase upon subsequent heat treatment. Opposite to this general observation, here, we report molecular design of thermally stable supercooled liquid of diketopyrrolopyrrole (DPP) derivatives and their intriguing shear-triggered crystallization with dramatic optical property changes. Molten DPP8, one of the DPP derivatives, remains as stable supercooled liquid without crystallization through subsequent thermal cycles. More interestingly, under shear conditions, this supercooled liquid DPP8 transforms to its crystal phase accompanied by a 25-fold increase in photoluminescence (PL) quantum efficiency and a color change. By systematic investigation on supercooled liquid formation of crystalline DPP derivatives and their correlation with chemical structures, we reveal that the origin of this thermally stable supercooled liquid is a subtle force balance between aromatic interactions among the core units and van der Waals interactions among the aliphatic side chains acting in opposite directions. Moreover, by applying shear force to a supercooled liquid DPP8 film at different temperatures, we demonstrated direct writing of fluorescent patterns and propagating fluorescence amplification, respectively. Shear-triggered crystallization of DPP8 is further achieved even by living cell attachment and spreading, demonstrating the high sensitivity of the shear-triggered crystallization which is about 6 orders of magnitude more sensitive than typical mechanochromism observed in organic materials. PMID:27162955

  14. Shear-Triggered Crystallization and Light Emission of a Thermally Stable Organic Supercooled Liquid.

    PubMed

    Chung, Kyeongwoon; Kwon, Min Sang; Leung, Brendan M; Wong-Foy, Antek G; Kim, Min Su; Kim, Jeongyong; Takayama, Shuichi; Gierschner, Johannes; Matzger, Adam J; Kim, Jinsang

    2015-05-27

    Thermodynamics drive crystalline organic molecules to be crystallized at temperatures below their melting point. Even though molecules can form supercooled liquids by rapid cooling, crystalline organic materials readily undergo a phase transformation to an energetically favorable crystalline phase upon subsequent heat treatment. Opposite to this general observation, here, we report molecular design of thermally stable supercooled liquid of diketopyrrolopyrrole (DPP) derivatives and their intriguing shear-triggered crystallization with dramatic optical property changes. Molten DPP8, one of the DPP derivatives, remains as stable supercooled liquid without crystallization through subsequent thermal cycles. More interestingly, under shear conditions, this supercooled liquid DPP8 transforms to its crystal phase accompanied by a 25-fold increase in photoluminescence (PL) quantum efficiency and a color change. By systematic investigation on supercooled liquid formation of crystalline DPP derivatives and their correlation with chemical structures, we reveal that the origin of this thermally stable supercooled liquid is a subtle force balance between aromatic interactions among the core units and van der Waals interactions among the aliphatic side chains acting in opposite directions. Moreover, by applying shear force to a supercooled liquid DPP8 film at different temperatures, we demonstrated direct writing of fluorescent patterns and propagating fluorescence amplification, respectively. Shear-triggered crystallization of DPP8 is further achieved even by living cell attachment and spreading, demonstrating the high sensitivity of the shear-triggered crystallization which is about 6 orders of magnitude more sensitive than typical mechanochromism observed in organic materials. PMID:27162955

  15. Compressed and saturated liquid densities for 18 halogenated organic compounds

    SciTech Connect

    Defibaugh, D.R.; Moldover, M.R.

    1997-01-01

    The pressure-density-temperature P({rho},T) behavior of 18 liquids that are potential working fluids in thermal machinery has been measured using a vibrating tube densimeter. For each liquid, the data were taken on isotherms spaced at intervals of 5 K to 10 K spanning the temperature range 245 K to 370 K. The pressures ranged from just above the vapor pressure (or the critical pressure) to 6500 kPa. The results of measurements at more than 12,000 thermodynamic points are summarized by correlating functions. Comparison with data from other laboratories indicates that the relative expanded uncertainty in the measured densities is less than 0.05%, except in the critical region. The repeatability of the vapor pressure to obtain the density of the liquid at the vapor pressure. The fluids studied (and their designations by the refrigeration industry) were trichlorofluoromethane (R11), chlorodifluoromethane (R22), 1,1-dichloro-2,2,2-trifluoroethane (R123), 1,2-dichloro-1,2,2-trifluoroethane (R123a), 1-chloro-1,2,2,2-tetrafluoroethane (R124), 1,1,2,2-tetrafluoroethane (R134), 1,1,1,2-tetrafluoroethane (R134a), 1,1-dichloro-1-fluoroethane (R141b), 1,1,1-trifluoroethane (R143), 1,1,2-trifluoroethane (R143a), pentafluorodimethyl ether (E125), 1,1-difluoroethane (R152a), octafluoropropane (R218), 1,1,1,2,3,3,3-heptafluoropropane (R227ea), 2-(difluoromethoxy)-1,1,1-trifluoroethane (E245), 1,1,1,2,2-pentafluoropropane (R245cb), 1,1,1,3,3-pentafluoropropane (R245fa), and propane (R290).

  16. Sorption of vapors of some organic liquids on soil humic acid and its relation to partitioning of organic compounds in soil organic matter

    USGS Publications Warehouse

    Chlou, G.T.; Kile, D.E.; Malcolm, R.L.

    1988-01-01

    Vapor sorption of water, ethanol, benzene, hexane, carbon tetrachloride, 1,1,1-trichloroethane, trichloroethylene, tetrachloroethylene, and 1,2-dibromoethane on (Sanhedron) soil humic acid has been determined at room temperature. Isotherms for all organic liquids are highly linear over a wide range of relative pressure (P/P??), characteristic of the partitioning (dissolution) of the organic compounds in soil humic acid. Polar liquids exhibit markedly greater sorption capacities on soil humic acid than relatively nonpolar liquids, in keeping with the polar nature of the soil humic acid as a partition medium. The limiting sorption (partition) capacities of relatively non-polar liquids are remarkably similar when expressed in terms of volumes per unit weight of soil humic acid. The soil humic acid is found to be about half as effective as soil organic matter in sorption of relatively nonpolar organic compounds. The nearly constant limiting sorption capacity for nonpolar organic liquids with soil humic acid on a volume-to-weight basis and its efficiency in sorption relative to soil organic matter provide a basis for predicting the approximate sorption (partition) coefficients of similar compounds in uptake by soil in aqueous systems.

  17. Underwater Spontaneous Pumpless Transportation of Nonpolar Organic Liquids on Extreme Wettability Patterns.

    PubMed

    Huang, Shuai; Song, Jinlong; Lu, Yao; Chen, Faze; Zheng, Huanxi; Yang, Xiaolong; Liu, Xin; Sun, Jing; Carmalt, Claire J; Parkin, Ivan P; Xu, Wenji

    2016-02-10

    Spontaneous pumpless transportation (SPT) of liquids has generated tremendous demands in microfluidic systems and advanced devices. However, the transportation of nonpolar organic liquids on open platforms underwater remains a challenge because most existing SPT systems are only designed for use in air. Here, we report a surface-tension-driven SPT system to transport various nonpolar organic liquids using underwater extreme wettability patterns. The patterns were fabricated with a wedge-shaped superoleophilic track on a superoleophobic background by combining CuCl2 etching, stearic acid modification, and mask-based nitrogen cold plasma treatment. Three types of underwater SPT processes-horizontal transport, tilted transport, and directional transport-were studied experimentally and theoretically. For horizontal SPT and tilted SPT, the capillary force was the main driving force, which depended on the wedge angle of the superoleophilic track. The excellent transportation ability of horizontal SPT of underwater liquid droplets was obtained at a wedge angle of 3-5°. The maximum moving height of organic liquids on the tilted SPT transport was obtained at an angle of 8°. For directional SPT, organic liquids did not drop off in the moving process because of the constraint imposed by surface tension, resulting in the sustained directional transport with long distances and complex trajectories. PMID:26785602

  18. High liquid yield process for retorting various organic materials including oil shale

    DOEpatents

    Coburn, Thomas T.

    1990-01-01

    This invention is a continuous retorting process for various high molecular weight organic materials, including oil shale, that yields an enhanced output of liquid product. The organic material, mineral matter, and an acidic catalyst, that appreciably adsorbs alkenes on surface sites at prescribed temperatures, are mixed and introduced into a pyrolyzer. A circulating stream of olefin enriched pyrolysis gas is continuously swept through the organic material and catalyst, whereupon, as the result of pyrolysis, the enhanced liquid product output is provided. Mixed spent organic material, mineral matter, and cool catalyst are continuously withdrawn from the pyrolyzer. Combustion of the spent organic material and mineral matter serves to reheat the catalyst. Olefin depleted pyrolysis gas, from the pyrolyzer, is enriched in olefins and recycled into the pyrolyzer. The reheated acidic catalyst is separated from the mineral matter and again mixed with fresh organic material, to maintain the continuously cyclic process.

  19. A high liquid yield process for retorting various organic materials including oil shale

    DOEpatents

    Coburn, T.T.

    1988-07-26

    This invention is a continuous retorting process for various high molecular weight organic materials, including oil shale, that yields an enhanced output of liquid product. The organic material, mineral matter, and an acidic catalyst, that appreciably adsorbs alkenes on surface sites at prescribed temperatures, are mixed and introduced into a pyrolyzer. A circulating stream of olefin enriched pyrolysis gas is continuously swept through the organic material and catalyst, whereupon, as the result of pyrolysis, the enhanced liquid product output is provided. Mixed spent organic material, mineral matter, and cool catalyst are continuously withdrawn from the pyrolyzer. Combustion of the spent organic material and mineral matter serves to reheat the catalyst. Olefin depleted pyrolysis gas, from the pyrolyzer, is enriched in olefins and recycled into the pyrolyzer. The reheated acidic catalyst is separated from the mineral matter and again mixed with fresh organic material, to maintain the continuously cyclic process. 2 figs.

  20. Analysis of a gas-liquid film plasma reactor for organic compound oxidation.

    PubMed

    Hsieh, Kevin; Wang, Huijuan; Locke, Bruce R

    2016-11-01

    A pulsed electrical discharge plasma formed in a tubular reactor with flowing argon carrier gas and a liquid water film was analyzed using methylene blue as a liquid phase hydroxyl radical scavenger and simultaneous measurements of hydrogen peroxide formation. The effects of liquid flow rate, liquid conductivity, concentration of dye, and the addition of ferrous ion on dye decoloration and degradation were determined. Higher liquid flow rates and concentrations of dye resulted in less decoloration percentages and hydrogen peroxide formation due to initial liquid conductivity effects and lower residence times in the reactor. The highest decoloration energy yield of dye found in these studies was 5.2g/kWh when using the higher liquid flow rate and adding the catalyst. The non-homogeneous nature of the plasma discharge favors the production of hydrogen peroxide in the plasma-liquid interface over the chemical oxidation of the organic in the bulk liquid phase and post-plasma reactions with the Fenton catalyst lead to complete utilization of the plasma-formed hydrogen peroxide. PMID:27267693

  1. LABORATORY INVESTIGATION OF RESIDUAL LIQUID ORGANICS FROM SPILLS, LEAKS, AND THE DISPOSAL OF HAZARDOUS WASTES IN GROUNDWATER

    EPA Science Inventory

    Organic liquids that are essentially immiscible with water migrate through the subsurface under the influence of capillary, viscous, and buoyancy forces. These liquids originate from the improper disposal of hazardous wastes, and the spills and leaks of petroleum hydrocarbons a...

  2. Removal of non-ionic organic pollutants from water via liquid-liquid extraction.

    PubMed

    López-Montilla, Juan C; Pandey, Samir; Shah, Dinesh O; Crisalle, Oscar D

    2005-05-01

    The removal of model pollutants bromocresol green (BG) and phenol from water is demonstrated via two liquid-liquid extraction methods. Both methods exploit selective interactions established by the pollutant molecule with a surfactant, oil, or alcohol, and are variants of the more general Winsor systems where the phases are in contact along an extremely large interfacial area. In the first method the surfactant and the co-surfactant move from a predominantly oil-in-water microemulsion (Winsor I), to a middle phase microemulsion (Winsor III), and finally to a water-in-oil microemulsion (Winsor II), as the physicochemical conditions of salinity, temperature or hydrophilic-lipophilic balance of the surfactant system are varied. This method achieves better than 99% removal of the pollutant BG from water. It is argued that the removal is produced upon increasing the salinity of the system because the interaction of BG with a medium chain-length alcohol drives it to move along with the alcohol to another phase. The second method, which is scalable to industrial levels, uses a spontaneously produced water-in-oil microemulsion with large interfacial area that appears after bringing in contact water and a pre-formed Winsor II or Winsor III microemulsion system containing different surfactants and oils. The method is applied to the removal of phenol from water, and it is found that systems with polar oils such as ethyl butyrate or with cationic surfactants such as stearyl trimethylammonium chloride are more efficient in removing phenol than systems with normal alkanes or anionic surfactants. It is also shown that a microemulsion formed using a polar oil performs better than using only the polar oil as the extraction solvent. Finally, the efficiency of the second liquid-liquid extraction method can be increased from 69% in a single-stage process to 83% in a two-stage process, using the same total amount of extraction solvent. PMID:15899289

  3. Microbial consortium role in processing liquid waste of vegetables in Keputran Market Surabaya as organic liquid fertilizer ferti-plus

    NASA Astrophysics Data System (ADS)

    Rizqi, Fauziah; Supriyanto, Agus; Lestari, Intan; Lita Indri D., L.; Elmi Irmayanti, A.; Rahmaniyah, Fadilatur

    2016-03-01

    Many activities in this market is directly proportional to increase production of vegetables waste, especially surabaya. Therefore, in this study aims to utilize liquid waste of vegetables into liquid organic fertilizer by mixing microbial consorsium. The microbial consorsium consist of Azotobacter chrococcum, Azospirillum brasilense, Rhizobium leguminosarum, Bacillus subtilis, Bacillus megaterium, Pseudomonas putida, and Pseudomonas fluorescens. Ttreatment of microbial concentrations (5%, 10%, 15%) and the length of the incubation period (7 days, 14 days, 21 days) used in this research. The parameters used are: C/N ratio, levels of CNP, and BOD value. This study uses a standard organic fertilizer value according SNI19-7030-2004, The results show the value of C/N ratio comply with the ISO standards. C levels showed an increase during the incubation period but not compare with standards. N levels that compare with standards are microbial treatment in all group concentration except control group with an incubation period of 21 days is > 7. P levels compare with the existing standards in the group of microbe concentration of 10% and 15% during the incubation period. The value of the initial BOD liquid waste of vegetable is 790.25 mg / L, this value indicates that the waste should not go into the water body. Accordingly, the results of this study can not be used as a liquid organic fertilizer, but potentially if it is used as a natural career or build natural soil. The Building natural soil is defined as the natural ingredients that can be used to improve soil properties.

  4. Liquid drop technique for generation of organic glass and metal shells

    NASA Technical Reports Server (NTRS)

    Hendricks, C. D.

    1982-01-01

    It was found that liquid drop techniques are very useful in several diverse areas. For producing very uniform metallic, organic, inorganic and, on particular, glassy shells, the liquid jet method is the most reproducible and exceptionally useful of all the techniques studied. The technique of capillary wave synchronization of the break-up of single and multiple component jets was utilized to produce uniform sized liquid drops and solid particles, and hollow liquid and solid shells. The technique was also used to encapsulate a number of liquids in impermeable spherical shells. Highly uniform glass shells were made by generating uniform drops of glass forming materials in an aqueous solution, subsequently evaporating the water, and then fusing and blowing the remaining solids in a high temperature vertical tube furnace. Experimental results are presented and the critical problems in further research in this field are discussed.

  5. Membrane permeation process for dehydration of organic liquid mixtures using sulfonated ion-exchange polyalkene membranes

    DOEpatents

    Cabasso, Israel; Korngold, Emmanuel

    1988-01-01

    A membrane permeation process for dehydrating a mixture of organic liquids, such as alcohols or close boiling, heat sensitive mixtures. The process comprises causing a component of the mixture to selectively sorb into one side of sulfonated ion-exchange polyalkene (e.g., polyethylene) membranes and selectively diffuse or flow therethrough, and then desorbing the component into a gas or liquid phase on the other side of the membranes.

  6. Direct Capture of Organic Acids From Fermentation Media Using Ionic Liquids

    SciTech Connect

    Klasson, K.T.

    2004-11-03

    Several ionic liquids have been investigated for the extraction of organic acids from fermentation broth. Partitioning of representative organic acids (lactic, acetic, and succinic) between aqueous solution and nine hydrophobic ionic liquids was measured. The extraction efficiencies were strongly dependent on pH of the aqueous phase. Distribution coefficient was very good (approximately 60) at low succinic acid concentrations for one of the ionic liquids (trihexyltetradecylphosphonium methanesulfonate) at neutral pH. However, this ionic liquid had to be diluted with nonanol due to its high viscosity in order to be useful. A diluent (trioctylamine) was also added to this mixture. The results suggest that an extraction system based on ionic liquids may be feasible for succinic acid recovery from fermentation broth and that two ideal extraction stages are needed to reduce the concentration from 33 g/L to 1 g/L of succinic acid. Further studies are needed to evaluate other issues related to practical applications, including ionic liquid loss in the process, toxicity effects of ionic liquids during simultaneous fermentation and extractions.

  7. Structural organization of liquid crystals at liquid crystal-air interface: Synchrotron X-ray reflectivity and computational simulations

    NASA Astrophysics Data System (ADS)

    Sadati, Monirosadat; Ramezani-Dakhel, Hadi; Bu, Wei; Sevgen, Emre; Liang, Zhu; Erol, Cem; Taheri Qazvini, Nader; Rahimi, Mohammad; Lin, Binhua; Roux, Benoit; Schlossman, Mark; de Pablo, Juan J.

    Numerous applications of liquid crystals (LC) rely on control of molecular orientation at an interface. However, little is known about the precise molecular structure of such interfaces. In this work, we have performed synchrotron X-ray reflectivity measurements accompanied by an advanced theoretical and computational analysis to study the structural organization of liquid crystals at the air-liquid crystal interface. The X-ray reflectivity was measured from two nematic (5CB) and smectic (8CB) liquid crystals at several temperatures, in the nematic phase and above the nematic-isotropic transition. Our computational simulations and X-ray reflectivity results indicate that in the case of 8CB nematic phase, incipient bulk smectic fluctuations are pinned at the interface to form temperature-dependent multilayers at the interface. Such layers can extend far from the interface. However, the interface of 5CB in the nematic phase exhibits a relatively small number of layers. These measurements will be extended to the study of the LC-aqueous electrolyte interfaces to understand the effects of electrostatic interactions and external stimuli on the interfacial anchoring energy and LC orientational ordering.

  8. Liquid organic foams for formulation optimization : an assessment of foam linear viscoelasticity and its temporal dependence.

    SciTech Connect

    Kropka, Jamie Michael; Celina, Mathias Christopher; Mondy, Lisa Ann

    2010-03-01

    Liquid foams are viscoelastic liquids, exhibiting a fast relaxation attributed to local bubble motions and a slow response due to structural evolution of the intrinsically unstable system. In this work, these processes are examined in unique organic foams that differ from the typically investigated aqueous systems in two major ways: the organic foams (1) posses a much higher continuous phase viscosity and (2) exhibit a coarsening response that involves coalescence of cells. The transient and dynamic relaxation responses of the organic foams are evaluated and discussed in relation to the response of aqueous foams. The change in the foam response with increasing gas fraction, from that of a Newtonian liquid to one that is strongly viscoelastic, is also presented. In addition, the temporal dependencies of the linear viscoelastic response are assessed in the context of the foam structural evolution. These foams and characterization techniques provide a basis for testing stabilization mechanisms in epoxy-based foams for encapsulation applications.

  9. Methods for calculation of engineering parameters for gas separation. [vapor pressure and solubility of gases in organic liquids

    NASA Technical Reports Server (NTRS)

    Lawson, D. D.

    1979-01-01

    A group additivity method is generated which allows estimation, from the structural formulas alone, of the energy of vaporization and the molar volume at 25 C of many nonpolar organic liquids. Using these two parameters and appropriate thermodynamic relations, the vapor pressure of the liquid phase and the solubility of various gases in nonpolar organic liquids are predicted. It is also possible to use the data to evaluate organic and some inorganic liquids for use in gas separation stages or liquids as heat exchange fluids in prospective thermochemical cycles for hydrogen production.

  10. Thin film scintillators

    NASA Astrophysics Data System (ADS)

    McDonald, Warren; McKinney, George; Tzolov, Marian

    2015-03-01

    Scintillating materials convert energy flux (particles or electromagnetic waves) into light with spectral characteristic matching a subsequent light detector. Commercial scintillators such as yttrium aluminum garnet (YAG) and yttrium aluminum perovskite (YAP) are commonly used. These are inefficient at lower energies due to the conductive coating present on their top surface, which is needed to avoid charging. We hypothesize that nano-structured thin film scintillators will outperform the commercial scintillators at low electron energies. We have developed alternative thin film scintillators, zinc tungstate and zinc oxide, which show promise for higher sensitivity to lower energy electrons since they are inherently conductive. Zinc tungstate films exhibit photoluminescence quantum efficiency of 74%. Cathodoluminescence spectroscopy was applied in transmission and reflection geometries. The comparison between the thin films and the YAG and YAP commercial scintillators shows much higher light output from the zinc tungstate and zinc oxide at electron energies less than 5 keV. Our films were integrated in a backscattered electron detector. This detector delivers better images than an identical detector with commercial YAG scintillator at low electron energies. Dr. Nicholas Barbi from PulseTor LLC, Dr. Anura Goonewardene, NSF Grants: #0806660, #1058829, #0923047.

  11. Enhanced mineralization of organic compounds in nonaqueous-phase liquids

    SciTech Connect

    Labare, M.P.; Alexander, M.

    1995-11-01

    Biodegradation of phenanthrene, biphenyl, or di(2-ethylhexyl) phthalate initially present in a variety of nonaqueous-phase liquids (NAPLs) was slow in samples of soil and aquifer solids. The NAPLs were hexadecane, dibutyl phthalate, 2, 2, 4 ,4, 6, 8, 8-heptamethylnonane, cyclohexane, commercial oils, crude oil, creosote, and kerosene. Slurrying the soil or aquifer solids markedly enhanced the rate and extent of mineralization of the test compounds initially in many of the NAPLs. Both the low rate and extent of mineralization of the three compounds initially in dibutyl phthalate in soil slurries and of di(2- ethylhexyl) phthalate in heptamethylnonane present in slurries of aquifer solids were increased by inoculation of acclimated microbial cultures. Increasing the NAPL volume decreased phenanthrene biodegradation in soil, but the effect of larger NAPL volume could be alleviated by slurrying and inoculation. The rate or extent of mineralization in aquifer slurries of di(2-ethylhexyi) phthalate initially in some NAPLs was increased by addition of N and P, and inoculation further enhanced the degradation.

  12. Ultrasonic imaging of organic liquid contaminants in unconsolidated porous media

    NASA Astrophysics Data System (ADS)

    Geller, Jil T.; Myer, Larry R.

    1995-08-01

    Laboratory experiments were conducted to measure the change in the ultrasonic wave signature as a function of the fraction of nonaqueous-phase liquid (NAPL) contaminants in initially water-saturated sand samples. This represents a fundamental step in the application of high-frequency seismic measurements to detect and delineate NAPL contamination in groundwater. The NAPL's used are n-dodecane, iso-octane and Freon 113®. P-wave velocity changes almost linearly as a function of the fraction of pore space occupied by NAPL. At a given NAPL fraction, the velocities rank with the bulk moduli of the NAPL's. The percent change in velocity at residual water saturation relative to the water-saturated medium ranges from 15% for n-dodecane to 31% for Freon 113®. Velocity changes are significant relative to the ability of seismic methods to detect changes on the order of 5%. These data are described by a model previously derived by G.T. Kuster and M.N. Toksöz of P-wave transmission through a fluid matrix with spherical inclusions that is modified to account for a two-fluid-phase matrix. Amplitude data as a function of NAPL fraction are described by assuming the distribution of NAPL in the column and using attenuation coefficients for the water-saturated and residual-water medium. Amplitudes are shown to be sensitive to both the fraction of NAPL and its distribution, whereas velocity is only a function of NAPL fraction.

  13. Remotely operated organic liquid waste incinerator for the fuels and materials examination facility

    SciTech Connect

    Sales, W.L.; Barker, R.E.; Hershey, R.B.

    1980-01-01

    The search for a practical method for the disposal of small quantities of oraganic liquid waste, a waste product of metallographic sample preparation at the Fuels and Materials Examination Facility has led to the design of an incinerator/off-gas system to burn organic liquid wastes and selected organic solids. The incinerator is to be installed in a shielded inert-atmosphere cell, and will be remotely operated and maintained. The off-gas system is a wet-scrubber and filter system designed to release particulate-free off-gas to the FMEF Building Exhaust System.

  14. Graphene oxide membrane for liquid phase organic molecular separation

    NASA Astrophysics Data System (ADS)

    Liu, Renlong; Arabale, Girish; Kim, Jinseon; Sun, Ke; Lee, Yongwoon; Ryu, Changkook; Lee, Changgu

    2015-03-01

    The selective permeation of organic solvents and water through graphene oxide (GO) membranes has been demonstrated. Water was found to permeate through GO membranes faster than various alcohols. The permeation rates of propanol are about 80 times lower than that of water. Taking advantage of the differences in the permeation rates, we separated water from the alcohols and obtained alcohols with high purity. For ethanol and 1-propanol, binary solutions of the alcohol and water were filtered efficiently to produce alcohols with concentration of about 97%. However, the selectivity of the filtration of methanol is significantly lower than those of the other alcohols. To understand the mechanism we followed the structural changes in the GO membranes by X-Ray diffraction analysis. From the X-ray diffraction results we speculate that the selectivity of the permeation of water and alcohols is closely related to the molecular sizes of the solvents and their polarity. In order to demonstrate the potential applications of this process for the selective removal of water from aqueous organic mixtures, we performed the separation of water from a bio-oil containing 73% of water. The majority of the water was filtered out resulting in a higher purity bio-oil.

  15. Use of water-equivalent plastic scintillator for intravascular brachytherapy dosimetry.

    PubMed

    Geso, M; Robinson, N; Schumer, W; Williams, K

    2004-03-01

    Beta irradiation has recently been investigated as a possible technique for the prevention of restenosis in intravascular brachytherapy after balloon dilatation or stent implantation. Present methods of beta radiation dosimetry are primarily conducted using radiochromic film. These film dosimeters exhibit limited sensitivity and their characteristics differ from those of tissue, therefore the dose measurement readings require correction factors to be applied. In this work a novel, mini-size (2 mm diameter by 5 mm long) dosimeter element fabricated from Organic Plastic Scintillator (OPS) material was employed. Scintillation photon detection is accomplished using a precision photodiode and innovative signal amplification and processing techniques, rather than traditional photomultiplier tube methods. A significant improvement in signal to noise ratio, dynamic range and stability is achieved using this set-up. In addition, use of the non-saturating organic plastic scintillator material as the detector enables the dosimeter to measure beta radiation at very close distances to the source. In this work the plastic scintillators have been used to measure beta radiation dose at distances of less than 1 mm from an Sr-90 cardiovascular brachytherapy source having an activity of about 2.1 GBq beta radiation levels for both depth-distance and longitudinal profile of the source pellet chain, both in air and in liquid water, are measured using this system. The data obtained is compared with results from Monte Carlo simulation technique (MCNP 4B). Plastic scintillator dosimeter elements, when used in conjunction with photodiode detectors may prove to be useful dosimeters for cardiovascular brachytherapy beta sources, or other applications where precise near-source field dosimetry is required. The system described is particularly useful where measurement of actual dose rate in real time, a high level of stability and repeatability, portability, and immediate access to results are

  16. A Scintillator Purification System for a Large Scale Solar Neutrino Experiment

    NASA Astrophysics Data System (ADS)

    Benziger, J. B.

    1999-08-01

    An on-line purification system for a large-scale low-background liquid scintillation detector has been tested with the 5-ton liquid scintillation detector, the Counting Test Facility at Gran Sasso. Counter-current water extraction removes polar and charged impurities such as ions and metal salts. Vacuum distillation of the entire scintillator has been applied to remove both radioactive impurities and chemical impurities that affect the optical properties of the scintillator. Filtration with a 0.05 μm particulate filter removed suspended dust particles that may contain U, Th and K. Nitrogen stripping was employed to remove dissolved water and noble gases (e.g. 85Kr) from the scintillator. The system has effectively reduced the internal back in the 5 ton liquid scintillation detector from 470+/-90 events/d to the detection limit of the detector (+/-45 events/d) in the energy window 250

  17. A scintillator purification system for a large scale solar neutrino experiment.

    NASA Astrophysics Data System (ADS)

    Benziger, J. B.; Johnson, M.; Calaprice, F. P.; Chen, M.; Darnton, N.; Loeser, R.; Vogelaar, R. B.

    1998-11-01

    An on-line purification system for a large-scale low-background liquid scintillation detector has been tested with the 5 t liquid scintillation detector, the Counting Test Facility at Gran Sasso. Counter-current water extraction removes polar and charged impurities such as ions and metal salts. Vacuum distillation of the entire scintillator has been applied to remove both radioactive impurities and chemical impurities that affect the optical properties of the scintillator. Filtration with a 0.05 μm particulate filter removed suspended dust particles that may contain U, Th and K. Nitrogen stripping was employed to remove dissolved water and noble gases (e.g. 85Kr) from the scintillator. The system has effectively reduced the internal back in the 5 t liquid scintillation detector from 470±90 events/d to the detection limit of the detector (±45 events/d) in the energy window 250 < E < 800 keV.

  18. NONIDEAL BEHAVIOR DURING COMPLETE DISSOLUTION OF ORGANIC IMMISCIBLE LIQUID IN NATURAL POROUS MEDIA

    PubMed Central

    Russo, A.E.; Mahal, M.K.; Brusseau, M.L.

    2011-01-01

    Experiments were conducted to investigate the complete dissolution of organic immiscible liquid residing within natural porous media. Organic-liquid dissolution was investigated by conducting experiments with homogeneously packed columns containing a residual saturation of organic liquid (trichloroethene). The porous media used comprised different textures (ranges of particle-size distributions) and organic-carbon contents. The dissolution behavior that was observed for the soil and aquifer sediment systems deviated from the behavior typically observed for systems composed of ideal sands. Specifically, multi-step elution curves were observed, with multiple extended periods of relatively constant contaminant flux. This behavior was more pronounced for the two media with larger particle-size distributions. Conversely, this type of dissolution behavior was not observed for the control system, which consisted of a well-sorted sand. It is hypothesized that the pore-scale configuration of the organic liquid and of the flow field is more complex for the poorly sorted media, and that this greater complexity constrains dissolution dynamics, leading to the observed nonideal behavior. PMID:19643542

  19. Liquid-Liquid Extraction and Solid Phase Extraction for Urinary Organic Acids: A Comparative Study from a Resource Constraint Setting.

    PubMed

    Kumari, Chandrawati; Varughese, Bijo; Ramji, Siddarth; Kapoor, Seema

    2016-10-01

    Pre analytical process of extraction for accurate detection of organic acids is a crucial step in diagnosis of organic acidemias by GCMS analysis. This process is accomplished either by solid phase extraction (SPE) or by liquid-liquid extraction (LLE). Both extraction procedures are used in different metabolic laboratories all over the world. In this study we compared these two extraction procedures in respect of precision, accuracy, percent recovery of metabolites, number of metabolites isolated, time and cost in a resource constraint setup. We observed that the mean recovery from SPE was 84.1 % and by LLE it was 77.4 % (p value <0.05). Moreover, the average number of metabolites isolated by SPE and LLE was 161.8 ± 18.6 and 140.1 ± 20.4 respectively. The processing cost of LLE was economical. In a cost constraint setting using LLE may be the practical option if used for organic acid analysis. PMID:27605738

  20. PREDICTION OF THE SOLUBILITY, ACTIVITY COEFFICIENT AND LIQUID/LIQUID PARTITION COEFFICIENT OF ORGANIC COMPOUNDS

    EPA Science Inventory

    Solvation models, based on fundamental chemical structure theory, were developed in the SPARC mechanistic tool box to predict a large array of physical properties of organic compounds in water and in non-aqueous solvents strictly from molecular structure. The SPARC self-interact...

  1. Organic Decomposition Performance of In-line Liquid Treatment System Using Microwave Plasma

    NASA Astrophysics Data System (ADS)

    Ito, Michiko; Takashima, Seigo; Nomura, Norio; Nomura, Tominori; Toyoda, Hirotaka

    2015-09-01

    Plasmas production in the vicinity of gas-liquid interface is expected as a new liquid treatment technique due to its high production rate of chemically reactive species (OH, O, etc.) and fast transfer of reactive species in liquid phase. So far, we have proposed a microwave plasma device using Venturi effect to treat a liquid, and have reported drastically-enhanced processing performance of organic decomposition by this plasma source. In this study, decomposition performance of various organic compounds such as phenol, methylene blue or diethylenetriamine is investigated. In the experiment, plasma is produced inside a gap between top and bottom parts of the nozzle by a pulsed 2.45 GHz microwave (peak power: <1.2 W, pulse repetition frequency: 10 kHz). During the plasma treatment, solutions are continuously supplied to the nozzle at a flow speed of 10.5 ~ 22.0 m/s. After the treatment, residual concentration is evaluated by high performance liquid chromatography, gas chromatography and so on. The result indicates the decomposition efficiency becomes different depending on organic matters. Origin of the efficiency difference will be discussed.

  2. Capture and release of mixed acid gasses with binding organic liquids

    DOEpatents

    Heldebrant, David J.; Yonker, Clement R.

    2010-09-21

    Reversible acid-gas binding organic liquid systems that permit separation and capture of one or more of several acid gases from a mixed gas stream, transport of the liquid, release of the acid gases from the ionic liquid and reuse of the liquid to bind more acid gas with significant energy savings compared to current aqueous systems. These systems utilize acid gas capture compounds made up of strong bases and weak acids that form salts when reacted with a selected acid gas, and which release these gases when a preselected triggering event occurs. The various new materials that make up this system can also be included in various other applications such as chemical sensors, chemical reactants, scrubbers, and separators that allow for the specific and separate removal of desired materials from a gas stream such as flue gas.

  3. Self-Assembled Fibers Containing Stable Organic Radical Moieties: Alignment and Magnetic Properties in Liquid Crystals.

    PubMed

    Eimura, Hiroki; Umeta, Yoshikazu; Tokoro, Hiroko; Yoshio, Masafumi; Ohkoshi, Shin-Ichi; Kato, Takashi

    2016-06-20

    Macroscopically oriented stable organic radicals have been obtained by using a liquid-crystalline (LC) gel composed of an l-isoleucine-based low molecular weight gelator containing a 2,2,6,6-tetramethylpiperidine 1-oxyl moiety. The LC gel has allowed magnetic measurements of the oriented organic radical. The gelator has formed fibrous aggregates in liquid crystals via intermolecular hydrogen bonds. The fibrous aggregates of the radical gelator are formed and oriented on cooling by applying a magnetic field to the mixture of liquid crystals and the gelator. Superconducting quantum interference device (SQUID) measurements have revealed that both oriented and nonoriented fibrous aggregates exhibited antiferromagnetic interactions, in which super-exchange interaction constant J is estimated as -0.89 cm(-1) . PMID:27219716

  4. Dissolution, Cyclodextrin-Enhanced Solubilization, and Mass Removal of an Ideal Multicomponent Organic Liquid

    PubMed Central

    Carroll, Kenneth C.; Brusseau, Mark L.

    2010-01-01

    Laboratory experiments and mathematical modeling were conducted to examine the influence of a hydroxypropyl-beta-cyclodextrin (HPCD) solution on the dissolution of single- and three-component organic liquids. The results of batch experiments showed that HPCD-enhanced solubilization of the organic-liquid mixtures was ideal (describable using Raoult’s Law), and that solubilization-enhancement factors were independent of mixture composition. Addition of the HPCD solution to columns containing residual saturations of the organic liquid enhanced the dissolution and removal of all three compounds in the mixture. The results of the column experiments and multicomponent rate-limited dissolution modeling suggest that solubilization was ideal for both water and cyclodextrin flushing. Concomitantly, the mass-flux reduction versus mass removal behavior was ideal for all experiments. Mass transfer was increased for HPCD solubilization relative to the water flushing due to solubility and concentration-gradient enhancement. Organic-liquid composition did not significantly impact mass transfer coefficients, and fractional mass removal behavior during HPCD solubilization was nearly identical for each compound whether present as a single component or in a mixture. Additionally, mass transfer coefficients for aqueous and HPCD solubilization for single and multicomponent mixtures were not statistically different upon normalizing by the solubility enhancement factor. PMID:19233508

  5. Fertigation with liquid fish emulsion for organic production of highbush blueberry

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Liquid fish emulsion is a common fertilizer used for organic production of highbush blueberry. The product is often applied by hand or with a sprayer but can also be injected through a drip irrigation system, otherwise referred to as fertigation. Fertigation is more efficient and less labor-intensiv...

  6. The Recovery and Identification of Flammable Liquids in Suspected Arsons: An Undergraduate Organic Experiment

    ERIC Educational Resources Information Center

    Blackledge, Robert D.

    1974-01-01

    Describes an experiment which can be used to test for the use of accelerants in the origin of a fire. Involves distillation and gas liquid chromatography to identify the accelerants, thus combining two experiments ordinarily included in the beginning organic laboratory. (SLH)

  7. IMPACT OF ORGANIC COMPOUNDS ON THE CONCENTRATIONS OF LIQUID WATER IN AMBIENT PM2.5

    EPA Science Inventory

    A field study was undertaken during the summer of 2000 to assess the impact of the presence of organic compounds on the liquid water concentrations of PM2.5 samples. The selected site, located in Research Triangle Park, North Carolina, was in a semi-rural environment with expe...

  8. ON-LINE DEOXYGENATION IN REDUCTIVE (AND OXIDATIVE) AMPEROMETRIC DETECTION: ENVIRONMENTAL APPLICATIONS IN THE LIQUID CHROMATOGRAPHY OF ORGANIC PEROXIDES

    EPA Science Inventory

    Cyclic voltammetry was used qualitatively to characterize and determine the feasibility of the oxidation and reduction of selected organic peroxides and hydroperoxides at a glassy carbon electrode. Organic peroxides were determined using reversed-phase high-performance liquid chr...

  9. A compendium on the NIST radionuclide assays of the massic activity of {sup 63}Ni and {sup 55}Fe solutions used for an international intercomparison of liquid scintillation spectrometry techniques

    SciTech Connect

    Colle, R.; Zimmerman, B.E.

    1997-09-01

    The National Institute of Standards and Technology recently participated in an international measurement intercomparison for {sup 63}Ni and {sup 55}Fe, which was conducted among principal national radionuclidic metrology laboratories. The intercomparison was sponsored by EUROMET, and was primarily intended to evaluate the capabilities of liquid scintillation (LS) spectrometry techniques for standardizing nuclides that decay by low-energy {beta}-emission (like {sup 63}Ni) and by low-Z (atomic number) electron capture (like {sup 55}Fe). The intercomparison findings exhibit a very good agreement for {sup 63}Ni among the various participating laboratories, including that for NIST, which suggests that the presently invoked LS methodologies are very capable of providing internationally-compatible standardizations for low-energy {beta}-emitters. The results for {sup 55}Fe are in considerably poorer agreement, and demonstrated the existence of several unresolved problems. It has thus become apparent that there is a need for the various international laboratories to conduct rigorous, systematic evaluations of their LS capabilities in assaying radionuclides that decay by low-Z electron capture.

  10. Method of loading organic materials with group III plus lanthanide and actinide elements

    DOEpatents

    Bell, Zane W.; Huei-Ho, Chuen; Brown, Gilbert M.; Hurlbut, Charles

    2003-04-08

    Disclosed is a composition of matter comprising a tributyl phosphate complex of a group 3, lanthanide, actinide, or group 13 salt in an organic carrier and a method of making the complex. These materials are suitable for use in solid or liquid organic scintillators, as in x-ray absorption standards, x-ray fluorescence standards, and neutron detector calibration standards.

  11. Scintillator phase of the SNO+ experiment

    NASA Astrophysics Data System (ADS)

    Lozza, V.; SNO+ Collaboration

    2012-07-01

    The SNO+ experiment is the follow up of the SNO experiment, replacing the heavy water volume with about 780 tons of liquid scintillator (LAB) in order to shift the sensitive threshold to lower energy range. The 6000 m.w.e. natural rock shielding, and the use of ultra-clean materials makes the detector suitable for the detection of pep and CNO solar neutrinos, geo-neutrinos, reactor neutrinos and the possible observation of neutrinos from supernovae. Complementing this program, SNO+ will also search for 150Nd (5.6% abundance) neutrinoless double beta decay, loading the liquid scintillator with 0.1% of natural Neodymium. After a review of the general SNO+ setup, the physics of the solar neutrino phase will be presented.

  12. EVALUATION OF A CONTINUOUS LIQUID-LIQUID EXTRACTOR FOR ISOLATION AND CONCENTRATION OF NONPOLAR ORGANICS FOR BIOLOGICAL TESTING IN THE PRESENCE OF HUMIC MATERIALS

    EPA Science Inventory

    A continuous liquid-liquid extraction system (CLLE) for concentrating trace organics from water into methylene chloride for analysis was designed, built and evaluated. The CLLE uses Teflon coils for phase contact and gravity phase separation. The system includes a self-contained ...

  13. EVALUATION OF A TEFLON HELIX LIQUID-LIQUID EXTRACTOR FOR CONCENTRATION OF TRACE ORGANICS FROM WATER INTO METHYLENE CHLORIDE (JOURNAL VERSION)

    EPA Science Inventory

    A continuous liquid-liquid extraction system (CLLE) for concentrating trace organics from water into methylene chloride for analysis was designed, built and evaluated. The CLLE uses Teflon coils for phase contact and gravity phase separation. The system includes a self-contained ...

  14. DESCANT--The DEuterated SCintillator Array for Neutron Tagging

    NASA Astrophysics Data System (ADS)

    Bildstein, Vinzenz; Garrett, P. E.; Bandyopadhay, D.; Bangay, J.; Bianco, L.; Demand, G.; Hadinia, B.; Leach, K. G.; Sumithrarachchi, C.; Wong, J.; Ashley, S. F.; Crider, B. P.; McEllistrem, M. T.; Peters, E. E.; Prados-Estévez, F. M.; Yates, S. W.; Vanhoy, J. R.; Ball, G. C.; Garnsworthy, A. B.; Hackman, G.; Pearson, C. J.; Sarazin, F.

    2014-09-01

    The DESCANT array at TRIUMF is designed to track neutrons from RIB experiments. DESCANT is composed of 70 close-packed deuterated organic liquid scintillators coupled to digital fast read-out ADC modules. This configuration will permit online pulse-shape discrimination between neutron and γ-ray events. The anisotropy of the n - d scattering will allow distinction of higher neutron multiplicities from scattering within the array and determination of the neutron energy spectrum directly from the pulse-height spectrum without using TOF. A prototype detector has been tested with monoenergetic neutrons at the accelerator laboratory of the University of Kentucky and a 24Mg(3He, n)26Si experiment has been performed with eight DESCANT detectors and two HPGe detectors. The results of the tests and the status of DESCANT will be presented.

  15. Computation of liquid-liquid equilibria and phase stabilities: implications for RH-dependent gas/particle partitioning of organic-inorganic aerosols

    NASA Astrophysics Data System (ADS)

    Zuend, A.; Marcolli, C.; Peter, T.; Seinfeld, J. H.

    2010-08-01

    Semivolatile organic and inorganic aerosol species partition between the gas and aerosol particle phases to maintain thermodynamic equilibrium. Liquid-liquid phase separation into an organic-rich and an aqueous electrolyte phase can occur in the aerosol as a result of the salting-out effect. Such liquid-liquid equilibria (LLE) affect the gas/particle partitioning of the different semivolatile compounds and might significantly alter both particle mass and composition as compared to a one-phase particle. We present a new liquid-liquid equilibrium and gas/particle partitioning model, using as a basis the group-contribution model AIOMFAC (Zuend et al., 2008). This model allows the reliable computation of the liquid-liquid coexistence curve (binodal), corresponding tie-lines, the limit of stability/metastability (spinodal), and further thermodynamic properties of multicomponent systems. Calculations for ternary and multicomponent alcohol/polyol-water-salt mixtures suggest that LLE are a prevalent feature of organic-inorganic aerosol systems. A six-component polyol-water-ammonium sulphate system is used to simulate effects of relative humidity (RH) and the presence of liquid-liquid phase separation on the gas/particle partitioning. RH, salt concentration, and hydrophilicity (water-solubility) are identified as key features in defining the region of a miscibility gap and govern the extent to which compound partitioning is affected by changes in RH. The model predicts that liquid-liquid phase separation can lead to either an increase or decrease in total particulate mass, depending on the overall composition of a system and the particle water content, which is related to the hydrophilicity of the different organic and inorganic compounds. Neglecting non-ideality and liquid-liquid phase separations by assuming an ideal mixture leads to an overestimation of the total particulate mass by up to 30% for the composition and RH range considered in the six-component system

  16. Computation of liquid-liquid equilibria and phase stabilities: implications for RH-dependent gas/particle partitioning of organic-inorganic aerosols

    NASA Astrophysics Data System (ADS)

    Zuend, A.; Marcolli, C.; Peter, T.; Seinfeld, J. H.

    2010-05-01

    Semivolatile organic and inorganic aerosol species partition between the gas and aerosol particle phases to maintain thermodynamic equilibrium. Liquid-liquid phase separation into an organic-rich and an aqueous electrolyte phase can occur in the aerosol as a result of the salting-out effect. Such liquid-liquid equilibria (LLE) affect the gas/particle partitioning of the different semivolatile compounds and might significantly alter both particle mass and composition as compared to a one-phase particle. We present a new liquid-liquid equilibrium and gas/particle partitioning model, using as a basis the group-contribution model AIOMFAC (Zuend et al., 2008). This model allows the reliable computation of the liquid-liquid coexistence curve (binodal), corresponding tie-lines, the limit of stability/metastability (spinodal), and further thermodynamic properties of the phase diagram. Calculations for ternary and multicomponent alcohol/polyol-water-salt mixtures suggest that LLE are a prevalent feature of organic-inorganic aerosol systems. A six-component polyol-water-ammonium sulphate system is used to simulate effects of relative humidity (RH) and the presence of liquid-liquid phase separation on the gas/particle partitioning. RH, salt concentration, and hydrophilicity (water-solubility) are identified as key features in defining the region of a miscibility gap and govern the extent to which compound partitioning is affected by changes in RH. The model predicts that liquid-liquid phase separation can lead to either an increase or decrease in total particulate mass, depending on the overall composition of a system and the particle water content, which is related to the hydrophilicity of the different organic and inorganic compounds. Neglecting non-ideality and liquid-liquid phase separations by assuming an ideal mixture leads to an overestimation of the total particulate mass by up to 30% for the composition and RH range considered in the six-component system simulation

  17. Formation and organization of planar polymeric and nanocomposite nanostructures on liquid and solid surfaces

    NASA Astrophysics Data System (ADS)

    Khomutov, G. B.; Gainutdinov, R. V.; Gubin, S. P.; Kislov, V. V.; Rakhnyanskaya, A. A.; Sergeev-Cherenkov, A. N.; Tolstikhina, A. L.

    2004-09-01

    We describe a new approach to fabrication of organized planar polymeric and composite nanostructures based on synthetic reactions in organized polymeric Langmuir monolayer at the gas-liquid interface. Novel polymeric quasi-crystalline planar monomolecular structures were formed at the gas-aqueous phase interface using new water-insoluble amphiphilic polyelectrolyte molecules. Corresponding ultrathin polymeric nanoscale-ordered films and stable planar polymeric nanocomposite structures with organized inorganic nanoparticles (palladium, gold and iron oxide) grown in the polymeric monolayer were formed successfully on the solid substrate surfaces. The obtained nanostructures were characterized by atomic force microscopy and transmission electron microscopy techniques.

  18. Safety analysis of exothermic reaction hazards associated with the organic liquid layer in tank 241-C-103

    SciTech Connect

    Postma, A.K.; Bechtold, D.B.; Borsheim, G.L.; Grisby, J.M.; Guthrie, R.L.; Kummerer, M.; Turner, D.A.; Plys, M.G.

    1994-03-01

    Safety hazards associated with the interim storage of a potentially flammable organic liquid in waste Tank C-103 are identified and evaluated. The technical basis for closing the unreviewed safety question (USQ) associated with the floating liquid organic layer in this tank is presented.

  19. Ionospheric Scintillation Explorer (ISX)

    NASA Astrophysics Data System (ADS)

    Iuliano, J.; Bahcivan, H.

    2015-12-01

    NSF has recently selected Ionospheric Scintillation Explorer (ISX), a 3U Cubesat mission to explore the three-dimensional structure of scintillation-scale ionospheric irregularities associated with Equatorial Spread F (ESF). ISX is a collaborative effort between SRI International and Cal Poly. This project addresses the science question: To what distance along a flux tube does an irregularity of certain transverse-scale extend? It has been difficult to measure the magnetic field-alignment of scintillation-scale turbulent structures because of the difficulty of sampling a flux tube at multiple locations within a short time. This measurement is now possible due to the worldwide transition to DTV, which presents unique signals of opportunity for remote sensing of ionospheric irregularities from numerous vantage points. DTV spectra, in various formats, contain phase-stable, narrowband pilot carrier components that are transmitted simultaneously. A 4-channel radar receiver will simultaneously record up to 4 spatially separated transmissions from the ground. Correlations of amplitude and phase scintillation patterns corresponding to multiple points on the same flux tube will be a measure of the spatial extent of the structures along the magnetic field. A subset of geometries where two or more transmitters are aligned with the orbital path will be used to infer the temporal development of the structures. ISX has the following broad impact. Scintillation of space-based radio signals is a space weather problem that is intensively studied. ISX is a step toward a CubeSat constellation to monitor worldwide TEC variations and radio wave distortions on thousands of ionospheric paths. Furthermore, the rapid sampling along spacecraft orbits provides a unique dataset to deterministically reconstruct ionospheric irregularities at scintillation-scale resolution using diffraction radio tomography, a technique that enables prediction of scintillations at other radio frequencies, and

  20. Research on radiation detectors, boiling transients, and organic lubricants

    NASA Technical Reports Server (NTRS)

    1974-01-01

    The accomplishments of a space projects research facility are presented. The subjects discussed are: (1) a study of radiation resistant semiconductor devices, (2) synthesis of high temperature organic lubricants, (3) departure from phase equilibrium during boiling transients, (4) effects of neutron irradiation on defect state in tungsten, and (5) determination of photon response function of NE-213 liquid scintillation detectors.

  1. CO2-Binding-Organic-Liquids-Enhanced CO2 Capture using Polarity-Swing-Assisted Regeneration

    SciTech Connect

    Zhang, Jian; Kutnyakov, Igor; Koech, Phillip K.; Zwoster, Andy; Howard, Chris; Zheng, Feng; Freeman, Charles J.; Heldebrant, David J.

    2013-01-01

    A new solvent-based CO2 capture process couples the unique attributes of non-aqueous, CO2-binding organic liquids (CO2BOLs) with the newly discovered polarity-swing-assisted regeneration (PSAR) process that is unique to switchable ionic liquids. Laboratory measurements with PSAR indicate the ability to achieve a regeneration effect at 75°C comparable to that at 120°C using thermal regeneration only. Initial measurements also indicate that the kinetic behavior of CO2 release is also improved with PSAR. Abstract cleared PNWD-SA-9743

  2. Cationic Ionic Liquids Organic Ligands Based Metal-Organic Frameworks for Fabrication of Core-Shell Microspheres for Hydrophilic Interaction Liquid Chromatography.

    PubMed

    Dai, Qian; Ma, Junqian; Ma, Siqi; Wang, Shengyu; Li, Lijun; Zhu, Xianghui; Qiao, Xiaoqiang

    2016-08-24

    In this study, new metal-organic frameworks (MOFs) nanocrystals modified SiO2 core-shell microspheres were designed with cationic ionic liquids (ILs) 1,3-bis(4-carboxybutyl)imidazolium bromide (ILI) as organic ligands. By further adjustment the growth cycles, the new ILI-01@SiO2 core-shell stationary phase was facilely fabricated. The developed stationary phase was respectively characterized via element analysis, thermogravimetric analysis, scanning electron microscopy, X-ray diffraction, and Fourier transform infrared spectrometry. Because the introduction of cationic imidazolium-based ILs ILI for fabrication of the MOFs nanocrystals shell, the new stationary phase exhibits the retention mechanism of hydrophilic interaction liquid chromatography (HILIC). Many polar samples, such as amides, vitamins, nucleic acid bases, and nucleosides, were utilized to investigate the performance of the prepared ILI-01@SiO2 column. Compared to the conventional aminosilica column, the new ILI-01@SiO2 column displays high separation selectivity in a shorter separation time. Furthermore, the new ILI-01@SiO2 column was also used for detection of illegal melamine addition in the baby formula. All the above results demonstrate the new ILI-01@SiO2 core-shell stationary phase is of good potentials for high-selectivity separation the polar samples. PMID:27483161

  3. Determination of 13 Organic Toxicants in Human Blood by Liquid-Liquid Extraction Coupling High-Performance Liquid Chromatography Tandem Mass Spectrometry.

    PubMed

    Song, Aiying

    2016-01-01

    Pesticides and antidepressants are frequently misused in drug-facilitated crime because of their toxicological effect and easy-availability. Therefore, it is essential for the development of a simple and reliable method for the determination of these organic toxicants in biological fluids. Here, we report on an applicable method by the combination of optimized liquid-liquid extraction (LLE) procedure and high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) to identify and quantify dimethoate, omethoate, dichlorvos, carbofuran, fenpropathrin, diazepam, estazolam, alprazolam, triazolamm, chlorpromazine, phenergan, barbitone and phenobarbital in human blood. The method demonstrated a linear calibration curve in range of 20 - 500 μg/L (r > 0.994). The accuracy evaluated by recovery spiked at three different concentrations (50, 100 and 200 μg/L) was in the range of 58.8 - 83.1% with a relative standard deviations (RSD) of 3.7 - 7.4%. The limits of quantification ranged over 6.7 - 33.3 μg/L. This method was proved to be simple and reliable, and was thus successfully applied to forensic toxicology. PMID:27302585

  4. Fast Scanning Calorimetry study of non-equilibrium relaxation in fragile organic liquids

    NASA Astrophysics Data System (ADS)

    Sadtchenko, Vlad; Bhattacharya, Deepanjan; O'Reilly, Liam

    2013-03-01

    Fast scanning calorimetry (FSC), capable of heating rates in excess of 1000000 K/s, was combined with vapor deposition technique to investigate non-equilibrium relaxation in micrometer thick viscous liquid films of several organic compounds (e.g.2-ethyl-1-hexanol, Toluene, and 1-propanol) under high vacuum conditions. Rapid heating of samples, vapor deposited at temperatures above their standard glass softening transition (Tg), resulted in observable endotherms which onset temperatures were strongly dependent on heating rate and the deposition temperature. Furthermore, all of the studied compounds were characterized by distinct critical deposition temperatures at which observation of endotherm became impossible. Based on the results of these studies, we have developed a simple model which makes it possible to infer the equilibrium enthalpy relaxation times for liquids from FSC data. We will discuss implications of these studies for contemporary models of non-equilibrium relaxation in glasses and supercooled liquids. Supported by NSF Grant 1012692.

  5. Evaluation of industrially applied heat-transfer fluids as liquid organic hydrogen carrier systems.

    PubMed

    Brückner, Nicole; Obesser, Katharina; Bösmann, Andreas; Teichmann, Daniel; Arlt, Wolfgang; Dungs, Jennifer; Wasserscheid, Peter

    2014-01-01

    Liquid organic hydrogen carrier (LOHC) systems offer a very attractive method for the decentralized storage of renewable excess energy. In this contribution, industrially well-established heat-transfer oils (typically sold under trade names, e.g., Marlotherm) are proposed as a new class of LOHC systems. It is demonstrated that the liquid mixture of isomeric dibenzyltoluenes (m.p. -39 to -34 °C, b.p. 390 °C) can be readily hydrogenated to the corresponding mixture of perhydrogenated analogues by binding 6.2 wt% of H2. The liquid H2 -rich form can be stored and transported similarly to diesel fuel. It readily undergoes catalytic dehydrogenation at temperatures above 260 °C, which proves its applicability as a reversible H2 carrier. The presented LOHC systems are further characterized by their excellent technical availability at comparably low prices, full registration of the H2 -lean forms, and excellent thermal stabilities. PMID:23956191

  6. Nature of Mesoscopic Organization in Protic Ionic Liquid-Alcohol Mixtures.

    PubMed

    Schroer, Wolffram; Triolo, Alessandro; Russina, Olga

    2016-03-10

    The mesoscopic morphology of mixtures of ethylammonium nitrate, a protic ionic liquid, and n-pentanol is explored for the first time using small angle X-ray scattering as a function of concentration and temperature. Both compounds are amphiphilic and characterized by an extended hydrogen bonding network; however, though macroscopically homogeneous, their mixtures are highly heterogeneous at the mesoscopic spatial scales. Previous structural studies rationalized similar features in related mixtures proposing the existence of large aggregates or micelle- and/or microemulsion-like structures. Here we show that a detailed analysis of the present concentration and temperature resolved experimental data set supports a structural scenario where the mesoscopic heterogeneities are the due to density fluctuations that are precursors of liquid-liquid phase separation. Accordingly no existence of structurally organized aggregates (such as micellar or microemulsion aggregates) is required to account for the mesoscopic heterogeneities detected in this class of binary mixtures. PMID:26895177

  7. Comparative testing of various flow-cell detectors fabricated using CaF{sub 2} solid scintillator

    SciTech Connect

    Kawano, T.; Ohashi, H.; Hamada, Y.; Jamsranjav, E.

    2015-03-15

    A monitoring system based on a flow-cell detector was developed for measuring the tritium concentration in water. The flow-cell detector was fabricated using a granular CaF{sub 2} solid scintillator. This system does not use a liquid scintillation counting system and does not generate radioactive organic liquid waste. Moreover, continuous real-time measurements are possible, in contrast to a liquid scintillation counting system, which requires batch measurements. For further development of the system, four flow-cell detectors were fabricated. They included a single 3-mm-diameter cell, three 3-mm-diameter cells in series, a single 5-mm-diameter cell, and three 5-mm-diameter cells in series. Continuously flowing water containing tritium at various concentrations was passed through the flow cells, and tritium count were measured for 600 and 10000 s. Investigating the relation between the count rate and concentration, the three 5-mm-diameter cells were most sensitive, with a linear relation maintained down to approximately 2 Bq/ml and 10 Bq/ml for 10000- and 600-s measurements, respectively. (authors)

  8. Scintillator plate calorimetry

    SciTech Connect

    Price, L.E.

    1990-01-01

    Calorimetry using scintillator plates or tiles alternated with sheets of (usually heavy) passive absorber has been proven over multiple generations of collider detectors. Recent detectors including UA1, CDF, and ZEUS have shown good results from such calorimeters. The advantages offered by scintillator calorimetry for the SSC environment, in particular, are speed (<10 nsec), excellent energy resolution, low noise, and ease of achieving compensation and hence linearity. On the negative side of the ledger can be placed the historical sensitivity of plastic scintillators to radiation damage, the possibility of nonuniform response because of light attenuation, and the presence of cracks for light collection via wavelength shifting plastic (traditionally in sheet form). This approach to calorimetry is being investigated for SSC use by a collaboration of Ames Laboratory/Iowa State University, Argonne National Laboratory, Bicron Corporation, Florida State University, Louisiana State University, University of Mississippi, Oak Ridge National Laboratory, Virginia Polytechnic Institute and State University, Westinghouse Electric Corporation, and University of Wisconsin.

  9. Improved Device Lifetime of Organic Light Emitting Diodes with an Electrochemically Stable π-Conjugated Liquid Host in the Liquid Emitting Layer

    NASA Astrophysics Data System (ADS)

    Hirata, Shuzo; Heo, Hyo Jung; Shibano, Yuki; Hirata, Osamu; Yahiro, Masayuki; Adachi, Chihaya

    2012-04-01

    The device lifetimes of organic light emitting diodes with a liquid emitting layer (liquid OLEDs) were improved by proper combination of host and guest molecules in the liquid emitting layer. The device lifetime strongly depends on the electrochemical stability of radical cations in the liquid emitting layer. The electrochemical stability of the liquid host materials was achieved by the dimerization of the alkyl-substituted carbazole 9,9'-2-[2-(2-methoxyethoxy)ethoxy]ethyl-3,3'-bis(9H-carbazole) [(TEGCz)2]. The use of a guest compound with its highest occupied molecular orbital level higher in energy than that of (TEGCz)2 is a critical factor for realizing stable electroluminescence performance. A liquid OLED with proper combination of the guest and host materials showed an improved device lifetime of longer than 1 h, which is 100 times longer than that of our previous reports.

  10. Characterizing and validating the PROSPECT segmented scintillator detector design

    NASA Astrophysics Data System (ADS)

    Norcini, Danielle; Prospect Collaboration

    2016-03-01

    The PROSPECT experiment will use two segmented liquid scintillator detectors positioned 7-20m from the High Flux Isotope Reactor (HFIR) core to perform a search for eV-scale sterile neutrinos and measure the antineutrino spectrum of uranium-235. A multi-year R&D program focused on background studies at the HFIR reactor, lithium-loaded liquid scintillator development, and characterization of multiple prototype detectors has culminated in the design of a segmented, 3-ton liquid scintillator detector for PROSPECT Phase I. This detector design is being validated with a 50 liter, 2-segment prototype detector, PROSPECT-50. We will report results of on-going performance and calibration studies and discuss implications for the PROSPECT physics program.

  11. Chemical Reactivity and Liquid/Nonliquid States of Secondary Organic Material.

    PubMed

    Li, Yong Jie; Liu, Pengfei; Gong, Zhaoheng; Wang, Yan; Bateman, Adam P; Bergoend, Clara; Bertram, Allan K; Martin, Scot T

    2015-11-17

    The reactivity of secondary organic material (SOM) of variable viscosity, ranging from nonliquid to liquid physical states, was studied. The SOM, produced in aerosol form from terpenoid and aromatic precursor species, was reacted with ammonia at variable relative humidity (RH). The ammonium-to-organic mass ratio (MNH4+/MOrg) increased monotonically from <5% RH to a limiting value at a threshold RH, implicating a transition from particle reactivity limited by diffusion at low RH to one limited by other factors at higher RH. For the studied size distributions and reaction times, the transition corresponded to a diffusivity above 10-17.5 ± 0.5 m2 s-1. The threshold RH values for the transition were <5% RH for isoprene-derived SOM, 35-45% RH for SOM derived from α-pinene, toluene, m-xylene, and 1,3,5-trimethylbenzene, and >90% for β-caryophyllene-derived SOM. The transition RH for reactivity differed in all cases from the transition RH of a nonliquid to a liquid state. For instance, for α-pinene-derived SOM the transition for chemical reactivity of 35-45% RH can be compared to the nonliquid to liquid transition of 65-90% RH. These differences imply that chemical transport models of atmospheric chemistry should not use the SOM liquid to nonliquid phase transition as one-to-one surrogates of SOM reactivity. PMID:26465059

  12. Comparison of imidazolium ionic liquids and traditional organic solvents: effect on activated sludge processes.

    PubMed

    Gendaszewska, Dorota; Liwarska-Bizukojc, Ewa

    2013-01-01

    Data concerning the biodegradability and ecotoxicity of ionic liquids (ILs) obtained so far are insufficient in the context of IL removal from wastewater in activated sludge systems. Thus, in this work the selected imidazolium ionic liquids and two organic solvents (methanol and acetone) were tested with respect to their influence on activated sludge processes, particularly on the morphology of sludge flocs. The presence of ionic liquids with the chemical structure of 1-alkyl-3-methyl imidazolium bromide in wastewater did not deteriorate biological wastewater treatment processes if their concentration was not higher than 5 mg l(-1). Regarding the structure of the ILs studied, the longer the alkyl substituent was, the stronger the effect on sludge flocs. The highest decrease in activated sludge floc area and biomass concentration was exerted by the ionic liquid with the longest alkyl chain, i.e. 1-decyl-3-methylimidazolium bromide. The action of both methanol and acetone on floc size, activated sludge concentration and efficiency of organic pollutants removal was weaker compared to all tested 1-alkyl-3-methyl imidazolium bromides. PMID:24355854

  13. Application of liquid chromatography-tandem mass spectrometry in quantitative bioanalyses of organic molecules in aquatic environment and organisms.

    PubMed

    Bussy, Ugo; Li, Ke; Li, Weiming

    2016-05-01

    Analytical methods using liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) for the simultaneous determination of metabolites or contaminants (or both) in various tissues of aquatic organisms and in the aquatic environment have received increasing attention in the last few years. This review discusses the findings relevant to such procedures published between 2005 and 2015. The aim is to evaluate the advantages, restrictions, and performances of the procedures from sample preparation to mass spectrometry measurement. To support these discussions, a general knowledge on LC-MS/MS is also provided. PMID:26996906

  14. A novel liquid organic hydrogen carrier system based on catalytic peptide formation and hydrogenation

    PubMed Central

    Hu, Peng; Fogler, Eran; Diskin-Posner, Yael; Iron, Mark A.; Milstein, David

    2015-01-01

    Hydrogen is an efficient green fuel, but its low energy density when stored under high pressure or cryogenically, and safety issues, presents significant disadvantages; hence finding efficient and safe hydrogen carriers is a major challenge. Of special interest are liquid organic hydrogen carriers (LOHCs), which can be readily loaded and unloaded with considerable amounts of hydrogen. However, disadvantages include high hydrogen pressure requirements, high reaction temperatures for both hydrogenation and dehydrogenation steps, which require different catalysts, and high LOHC cost. Here we present a readily reversible LOHC system based on catalytic peptide formation and hydrogenation, using an inexpensive, safe and abundant organic compound with high potential capacity to store and release hydrogen, applying the same catalyst for loading and unloading hydrogen under relatively mild conditions. Mechanistic insight of the catalytic reaction is provided. We believe that these findings may lead to the development of an inexpensive, safe and clean liquid hydrogen carrier system. PMID:25882348

  15. Basic technology for 6Li enrichment using an ionic-liquid impregnated organic membrane

    NASA Astrophysics Data System (ADS)

    Hoshino, Tsuyoshi; Terai, Takayuki

    2011-10-01

    The tritium needed as a fuel for fusion reactors is produced by the neutron capture reaction of lithium-6 ( 6Li) in tritium breeding materials. However, natural Li contains only about 7.6 at.% 6Li. In this paper, a new lithium isotope separation technique using an ionic-liquid impregnated organic membrane is proposed. In order to separate and concentrate lithium isotopes, only lithium ions are able to move through the membrane by electrodialysis between the cathode and the anode in lithium solutions. Preliminary experiments of lithium isotope separation were conducted using this phenomenon. Organic membranes impregnated with TMPA-TFSI and PP13-TFSI as ionic liquids were prepared, and the relationship between the 6Li separation coefficient and the applied electrodialytic conditions was evaluated using them. The results showed that the 6Li isotope separation coefficient in this method (about 1.1-1.4) was larger than that in the mercury amalgam method (about 1.06).

  16. Fast, non-linear optical-scattering spectroscopy in shock-compressed organic liquids

    SciTech Connect

    Schmidt, S.C.; Moore, D.S.; Schiferl, D.; Shaner, J.W.

    1983-01-01

    Nanosecond stimulated Raman and coherent anti-Stokes Raman scattering spectroscopy have been used to determine molecular vibrational frequency shifts and changes of phase in shock-compressed organic liquids. Results of dynamic experiments are compared to static Raman scattering measurements of samples, compressed and heated in a diamond-anvil cell. Objectives of the experiments are to determine the molecular structure and ultimately the energy transfer mechanisms in shock-compressed condensed phase materials.

  17. Technical Assessment of Organic Liquid Carrier Hydrogen Storage Systems for Automotive Applications

    SciTech Connect

    Ahluwalia, R. K.; Hua, T. Q.; Peng, J. -K; Kromer, M.; Lasher, S.; McKenney, K.; Law, K.; Sinha, J.

    2011-06-21

    In 2007-2009, the DOE Hydrogen Program conducted a technical assessment of organic liquid carrier based hydrogen storage systems for automotive applications, consistent with the Program’s Multiyear Research, Development, and Demonstration Plan. This joint performance (ANL) and cost analysis (TIAX) report summarizes the results of this assessment. These results should be considered only in conjunction with the assumptions used in selecting, evaluating, and costing the systems discussed here and in the Appendices.

  18. Scintillating Cocktail Mixtures and the Role of Water on the Optophysical Properties.

    SciTech Connect

    Cordaro, Joseph Gabriel; Feng, Patrick L.; Mengesha, Wondwosen; Murtagh, Dustin; Anstey, Mitchell

    2015-10-01

    Two types of water - containing liquid scinti llation mixtures were prepared in the present work. In the first, m ixtures of 2 - phenylethanol, water, diphenyl phosphate, sodium phenyl phosphate dibasic dihydrate, and the dye 2,5 - diphenyloxazole (PPO) have been investigated as liquid scintillators. In th e second system, nonionic and mixed surfactant systems were investigated in conjunction with water and small amounts of toluene. In both cases, increasing amounts of water led to reductions in the scintillation light yield. Understanding what factors contr ibute to this phenomenon is the focus of this report. Changes in the solution microphase structure, diminishing aromatic content of the cocktail mixtures, and inefficient energy transfer to the dye a ppear to be responsible for the decreased light yield as more water is added . In the 2 - phenylethanol system, the observed experimental results are consistent with the formation of a bicontinuous microemulsion at higher water concentrations, which incorporates PPO and shields it from the quenching effects of the increasing polar matrix. Evidence for this proposed phase chan ge c ome s from light scattering data, photo - and x - ray luminescence measurements, and optical transparency measurements . In the surfactant - based system, the quenching effect of water was found to be less than both commercially - available dioxane - naphthalene mixtures used for scintillation counting as well as the 2 - phenylethanol mixtures described above. The effect of different surfactant mixtures and concentrations were studied, revealing a benefic ial effect upon the scintillation light yield for mixed surfactant mixtures. These results are interpreted in the context of r eactive radical species formation following water ionization , which leads to light - yield quenching in aqueous systems . The presenc e of surfactant(s) in these mixtures enables the formation of organic - rich regions that are spatially separated from the

  19. Organic salt-assisted liquid-phase exfoliation of graphite to produce high-quality graphene

    NASA Astrophysics Data System (ADS)

    Du, Wencheng; Lu, Jie; Sun, Peipei; Zhu, Yinyan; Jiang, Xiaoqing

    2013-05-01

    Certain ordinary organic salts, such as edetate disodium, sodium tartrate, potassium sodium tartrate and sodium citrate were found to have universal and efficient assistant effect for liquid-phase exfoliation of graphite in common organic solvents to produce pristine graphene. Up to 123 times enhanced exfoliation efficiency was observed when sodium citrate was introduced into an exfoliation system consisting of natural graphite powder and dimethyl sulfoxide. TEM, AFM, Raman spectroscopy, EDX, TGA, and FTIR analysis showed graphite was successfully exfoliated into single or few-layer graphene nanosheets which were free of defects and oxides. The method is simple, effective, safe and economical.

  20. Metal-organic frameworks as host materials of confined supercooled liquids

    NASA Astrophysics Data System (ADS)

    Fischer, J. K. H.; Sippel, P.; Denysenko, D.; Lunkenheimer, P.; Volkmer, D.; Loidl, A.

    2015-10-01

    In this work, we examine the use of metal-organic framework (MOF) systems as host materials for the investigation of glassy dynamics in confined geometry. We investigate the confinement of the molecular glass former glycerol in three MFU-type MOFs with different pore sizes (MFU stands for "Metal-Organic Framework Ulm-University") and study the dynamics of the confined liquid via dielectric spectroscopy. In accord with previous reports on confined glass formers, we find different degrees of deviations from bulk behavior depending on pore size, demonstrating that MOFs are well-suited host systems for confinement investigations.

  1. Parameterizing liquid crystal variable retarder structural organization with a fractal-Born approximation model

    NASA Astrophysics Data System (ADS)

    Gladish, James C.; Duncan, Donald D.

    2016-05-01

    Liquid crystal variable retarders (LCVRs) are computer-controlled birefringent devices that contain nanometer-sized birefringent liquid crystals (LCs). These devices impart retardance effects through a global, uniform orientation change of the LCs, which is based on a user-defined drive voltage input. In other words, the LC structural organization dictates the device functionality. The LC structural organization also produces a spectral scatter component which exhibits an inverse power law dependence. We investigate LC structural organization by measuring the voltage-dependent LC spectral scattering signature with an integrating sphere and then relate this observable to a fractal-Born model based on the Born approximation and a Von Kármán spectrum. We obtain LCVR light scattering spectra at various drive voltages (i.e., different LC orientations) and then parameterize LCVR structural organization with voltage-dependent correlation lengths. The results can aid in determining performance characteristics of systems using LCVRs and can provide insight into interpreting structural organization measurements.

  2. Positive-ion thermospray liquid chromatography-mass spectrometry: detection of organic acidurias.

    PubMed

    Buchanan, D N; Muenzer, J; Thoene, J G

    1990-12-14

    Positive-ion thermospray liquid chromatography-mass spectrometry (TSP-LC-MS) is used to detect organic acids via the direct injection of untreated urine from newborns and infants. Two methods are reported for the separation of organic acids. The separation of urinary organic acids is effected in either an acidic, pH 2.5 sulfuric acid, or a non-acidic, 0.05 M ammonium acetate, pH 6.8, mobile phase. Use of pH 2.5 sulfuric acid and an HPX-87H organic acid column produces better separation but has less sensitivity than the use of 0.05 M ammonium acetate, pH 6.8 and a C18 column. Positive ion TSP-LC-MS has been used to detect methylmalonic aciduria, 3-hydroxy-3-methylglutaric aciduria, propionic aciduria, isovaleric aciduria and argininosuccinic aciduria. PMID:1709942

  3. Capabilities and limitations of dispersive liquid-liquid microextraction with solidification of floating organic drop for the extraction of organic pollutants from water samples.

    PubMed

    Vera-Avila, Luz E; Rojo-Portillo, Tania; Covarrubias-Herrera, Rosario; Peña-Alvarez, Araceli

    2013-12-17

    Dispersive liquid-liquid microextraction with solidification of floating organic drop (DLLME-SFO) is one of the most interesting sample preparation techniques developed in recent years. Although several applications have been reported, the potentiality and limitations of this simple and rapid extraction technique have not been made sufficiently explicit. In this work, the extraction efficiency of DLLME-SFO for pollutants from different chemical families was determined. Studied compounds include: 10 polycyclic aromatic hydrocarbons, 5 pesticides (chlorophenoxy herbicides and DDT), 8 phenols and 6 sulfonamides, thus, covering a large range of polarity and hydrophobicity (LogKow 0-7, overall). After optimization of extraction conditions using 1-dodecanol as extractant, the procedure was applied for extraction of each family from 10-mL spiked water samples, only adjusting sample pH as required. Absolute recoveries for pollutants with LogKow 3-7 were >70% and recovery values within this group (18 compounds) were independent of structure or hydrophobicity; the precision of recovery was very acceptable (RSD<12%) and linear behavior was observed in the studied concentration range (r(2)>0.995). Extraction recoveries for pollutants with LogKow 1.46-2.8 were in the range 13-62%, directly depending on individual LogKow values; however, good linearity (r(2)>0.993) and precision (RSD<6.5%) were also demonstrated for these polar solutes, despite recovery level. DLLME-SFO with 1-dodecanol completely failed for extraction of compounds with LogKow≤1 (sulfa drugs), other more polar extraction solvents (ionic liquids) should be explored for highly hydrophilic pollutants. PMID:24296144

  4. Insights into Mechanistic Models for Evaporation of Organic Liquids in the Environment Obtained by Position-Specific Carbon Isotope Analysis.

    PubMed

    Julien, Maxime; Nun, Pierrick; Robins, Richard J; Remaud, Gérald S; Parinet, Julien; Höhener, Patrick

    2015-11-01

    Position-specific isotope effects (PSIEs) have been measured by isotope ratio monitoring (13)C nuclear magnetic resonance spectrometry during the evaporation of 10 liquids of different polarities under 4 evaporation modes (passive evaporation, air-vented evaporation, low pressure evaporation, distillation). The observed effects are used to assess the validity of the Craig-Gordon isotope model for organic liquids. For seven liquids the overall isotope effect (IE) includes a vapor-liquid contribution that is strongly position-specific in polar compounds but less so in apolar compounds and a diffusive IE that is not position-specific, except in the alcohols, ethanol and propan-1-ol. The diffusive IE is diminished under forced evaporation. The position-specific isotope pattern created by liquid-vapor IEs is manifest in five liquids, which have an air-side limitation for volatilization. For the alcohols, undefined processes in the liquid phase create additional PSIEs. Three other liquids with limitations on the liquid side have a lower, highly position-specific, bulk diffusive IE. It is concluded that evaporation of organic pollutants creates unique position-specific isotope patterns that may be used to assess the progress of remediation or natural attenuation of pollution and that the Craig-Gordon isotope model is valid for the volatilization of nonpolar organic liquids with air-side limitation of the volatilization rate. PMID:26443423

  5. A scintillator purification plant and fluid handling system for SNO+

    SciTech Connect

    Ford, Richard J.

    2015-08-17

    A large capacity purification plant and fluid handling system has been constructed for the SNO+ neutrino and double-beta decay experiment, located 6800 feet underground at SNOLAB, Canada. SNO+ is a refurbishment of the SNO detector to fill the acrylic vessel with liquid scintillator based on Linear Alkylbenzene (LAB) and 2 g/L PPO, and also has a phase to load natural tellurium into the scintillator for a double-beta decay experiment with {sup 130}Te. The plant includes processes multi-stage dual-stream distillation, column water extraction, steam stripping, and functionalized silica gel adsorption columns. The plant also includes systems for preparing the scintillator with PPO and metal-loading the scintillator for double-beta decay exposure. We review the basis of design, the purification principles, specifications for the plant, and the construction and installations. The construction and commissioning status is updated.

  6. A scintillator purification plant and fluid handling system for SNO+

    NASA Astrophysics Data System (ADS)

    Ford, Richard J.

    2015-08-01

    A large capacity purification plant and fluid handling system has been constructed for the SNO+ neutrino and double-beta decay experiment, located 6800 feet underground at SNOLAB, Canada. SNO+ is a refurbishment of the SNO detector to fill the acrylic vessel with liquid scintillator based on Linear Alkylbenzene (LAB) and 2 g/L PPO, and also has a phase to load natural tellurium into the scintillator for a double-beta decay experiment with 130Te. The plant includes processes multi-stage dual-stream distillation, column water extraction, steam stripping, and functionalized silica gel adsorption columns. The plant also includes systems for preparing the scintillator with PPO and metal-loading the scintillator for double-beta decay exposure. We review the basis of design, the purification principles, specifications for the plant, and the construction and installations. The construction and commissioning status is updated.

  7. Boron loaded scintillator

    SciTech Connect

    Bell, Zane William; Brown, Gilbert Morris; Maya, Leon; Sloop, Jr., Frederick Victor; Sloop, Jr., Frederick Victor

    2009-10-20

    A scintillating composition for detecting neutrons and other radiation comprises a phenyl containing silicone rubber with carborane units and at least one phosphor molecule. The carbonate units can either be a carborane molecule dispersed in the rubber with the aid of a compatibilization agent or can be covalently bound to the silicone.

  8. Polysiloxane scintillator composition

    DOEpatents

    Walker, J.K.

    1992-05-05

    A plastic scintillator useful for detecting ionizing radiation comprising a matrix which comprises an optically transparent polysiloxane having incorporated therein at least one ionizing radiation-hard fluor capable of converting electromagnetic energy produced in the polysiloxane upon absorption of ionizing radiation to detectable light.

  9. SCINTILLATION EXPOSURE RATE DETECTOR

    DOEpatents

    Spears, W.G.

    1960-11-01

    A radiation detector for gamma and x rays is described. The detector comprises a scintillation crystal disposed between a tantalum shield and the input of a photomultiplier tube, the crystal and the shield cooperating so that their combined response to a given quantity of radiation at various energy levels is substantially constant.

  10. Polysiloxane scintillator composition

    DOEpatents

    Walker, James K.

    1992-01-01

    A plastic scintillator useful for detecting ionizing radiation comprising a matrix which comprises an optically transparent polysiloxane having incorporated therein at least one ionizing radiation-hard fluor capable of converting electromagnetic energy produced in the polysiloxane upon absorption of ionizing radiation to detectable light.

  11. Scintillator requirements for medical imaging

    SciTech Connect

    Moses, William W.

    1999-09-01

    Scintillating materials are used in a variety of medical imaging devices. This paper presents a description of four medical imaging modalities that make extensive use of scintillators: planar x-ray imaging, x-ray computed tomography (x-ray CT), SPECT (single photon emission computed tomography) and PET (positron emission tomography). The discussion concentrates on a description of the underlying physical principles by which the four modalities operate. The scintillator requirements for these systems are enumerated and the compromises that are made in order to maximize imaging performance utilizing existing scintillating materials are discussed, as is the potential for improving imaging performance by improving scintillator properties.

  12. Scintillator Waveguide For Sensing Radiation

    DOEpatents

    Bliss, Mary; Craig, Richard A.; Reeder; Paul L.

    2003-04-22

    The present invention is an apparatus for detecting ionizing radiation, having: a waveguide having a first end and a second end, the waveguide formed of a scintillator material wherein the therapeutic ionizing radiation isotropically generates scintillation light signals within the waveguide. This apparatus provides a measure of radiation dose. The apparatus may be modified to permit making a measure of location of radiation dose. Specifically, the scintillation material is segmented into a plurality of segments; and a connecting cable for each of the plurality of segments is used for conducting scintillation signals to a scintillation detector.

  13. Pyrolysis characteristics and pyrolysis products separation for recycling organic materials from waste liquid crystal display panels.

    PubMed

    Wang, Ruixue; Xu, Zhenming

    2016-01-25

    Waste liquid crystal display (LCD) panels mainly contain inorganic materials (glass substrate with indium-tin oxide film), and organic materials (polarizing film and liquid crystal). The organic materials should be removed beforehand since the organic matters would hinder the indium recycling process. In the present study, pyrolysis process is used to remove the organic materials and recycle acetic as well as and triphenyl phosphate (TPP) from waste LCD panels in an environmental friendly way. Several highlights of this study are summarized as follows: (i) Pyrolysis characteristics and pyrolysis kinetics analysis are conducted which is significant to get a better understanding of the pyrolysis process. (ii) Optimum design is developed by applying Box-Behnken Design (BBD) under response surface methodology (RSM) for engineering application which is significant to guide the further industrial recycling process. The oil yield could reach 70.53 wt% and the residue rate could reach 14.05 wt% when the pyrolysis temperature is 570 °C, nitrogen flow rate is 6 L min(-1) and the particle size is 0.5 mm. (iii) Furthermore, acetic acid and TPP are recycled, and then separated by rotary evaporation, which could reduce the consumption of fossil energy for producing acetic acid, and be reused in electronics manufacturing industry. PMID:26444486

  14. Chromatographic behavior of small organic compounds in low-temperature high-performance liquid chromatography using liquid carbon dioxide as the mobile phase.

    PubMed

    Motono, Tomohiro; Nagai, Takashi; Kitagawa, Shinya; Ohtani, Hajime

    2015-07-01

    Low-temperature high-performance liquid chromatography, in which a loop injector, column, and detection cell were refrigerated at -35ºC, using liquid carbon dioxide as the mobile phase was developed. Small organic compounds (polyaromatic hydrocarbons, alkylbenzenes, and quinones) were separated by low-temperature high-performance liquid chromatography at temperatures from -35 to -5ºC. The combination of liquid carbon dioxide mobile phase with an octadecyl-silica (C18 ) column provided reversed phase mode separation, and a bare silica-gel column resulted in normal phase mode separation. In both the cases, nonlinear behavior at approximately -15ºC was found in the relationship between the temperature and the retention factors of the analytes (van't Hoff plots). In contrast to general trends in high-performance liquid chromatography, the decrease in temperature enhanced the separation efficiency of both the columns. PMID:25917311

  15. Reflectance of polytetrafluoroethylene for xenon scintillation light

    SciTech Connect

    Silva, C.; Pinto da Cunha, J.; Pereira, A.; Chepel, V.; Lopes, M. I.; Solovov, V.; Neves, F.

    2010-03-15

    Gaseous and liquid xenon particle detectors are being used in a number of applications including dark matter search and neutrino-less double beta decay experiments. Polytetrafluoroethylene (PTFE) is often used in these detectors both as electrical insulator and as a light reflector to improve the efficiency of detection of scintillation photons. However, xenon emits in the vacuum ultraviolet (VUV) wavelength region ({lambda}{approx_equal}175 nm) where the reflecting properties of PTFE are not sufficiently known. In this work, we report on measurements of PTFE reflectance, including its angular distribution, for the xenon scintillation light. Various samples of PTFE, manufactured by different processes (extruded, expanded, skived, and pressed) have been studied. The data were interpreted with a physical model comprising both specular and diffuse reflections. The reflectance obtained for these samples ranges from about 47% to 66% for VUV light. Other fluoropolymers, namely, ethylene tetrafluoroethylene (ETFE), fluorinated ethylene propylene (FEP), and perfluoro-alkoxyalkane (PFA) were also measured.

  16. Reflectance of polytetrafluoroethylene for xenon scintillation light

    NASA Astrophysics Data System (ADS)

    Silva, C.; Pinto da Cunha, J.; Pereira, A.; Chepel, V.; Lopes, M. I.; Solovov, V.; Neves, F.

    2010-03-01

    Gaseous and liquid xenon particle detectors are being used in a number of applications including dark matter search and neutrino-less double beta decay experiments. Polytetrafluoroethylene (PTFE) is often used in these detectors both as electrical insulator and as a light reflector to improve the efficiency of detection of scintillation photons. However, xenon emits in the vacuum ultraviolet (VUV) wavelength region (λ ≃175 nm) where the reflecting properties of PTFE are not sufficiently known. In this work, we report on measurements of PTFE reflectance, including its angular distribution, for the xenon scintillation light. Various samples of PTFE, manufactured by different processes (extruded, expanded, skived, and pressed) have been studied. The data were interpreted with a physical model comprising both specular and diffuse reflections. The reflectance obtained for these samples ranges from about 47% to 66% for VUV light. Other fluoropolymers, namely, ethylene tetrafluoroethylene (ETFE), fluorinated ethylene propylene (FEP), and perfluoro-alkoxyalkane (PFA) were also measured.

  17. Assessment of survivability of liquid water and organic materials through modeling of large-scale impacts

    NASA Astrophysics Data System (ADS)

    Blank, Jennifer

    Comets, estimated to contain up to 25 wt.% organic material as both ices and more complex, refractory compounds, have been proposed as a vehicle for the delivery of organic compounds to the early Earth and other rocky planets. Successful delivery requires that some of the organic materials survive the extreme temperatures associated with impact, but the response of organic compounds to impact (shock) processing under these conditions is unknown. Several researchers have explored organic-delivery scenarios computationally and experimentally. Here, I will summarize work that addresses the issue of impact delivery and focus on current efforts to track the phase-state of water during a modeled comet-earth collision over a range of impact angles. On the basis of model results generated using a three-dimensional shock physics code (GEODYN), I will infer survivability of organic compounds and liquid water in a range of impact scenarios for comet-Earth and asteroid-Earth collisions. These results will be described in the context of the flux of astromaterials, and organic matter in particular, to young planets.

  18. Self-organized assemblies of colloidal particles obtained from an aligned chromonic liquid crystal dispersion.

    PubMed

    Zimmermann, Natalie; Jünnemann-Held, Gisela; Collings, Peter J; Kitzerow, Heinz-S

    2015-02-28

    The behavior of mono-disperse colloidal particles in a chromonic liquid crystal was investigated. Poly(methyl methacrylate) spherical particles with three different functionalizations, with and without surface charges, were utilized in the nematic and columnar phases of disodium cromoglycate solutions. The nematic phase was completely aligned parallel to the glass substrates by a simple rubbing technique, and the columnar phase showed regions of similar alignment. The behavior of the colloidal particles in the chromonic liquid crystal depended critically on the functionality, with bromine functionalized particles not dispersing at all, and cationic trimethylammonium and epoxy functionalized particles dispersing well in the isotropic phase of the liquid crystal. At the transition to the nematic and especially the columnar phase, the colloidal particles were expelled into the remaining isotropic phase. Since the columnar phase grew in parallel ribbons, the colloidal particles ended up in chain-like assemblies. Such behavior opens the possibility of producing patterned assemblies of colloidal particles by taking advantage of the self-organized structure of chromonic liquid crystals. PMID:25589441

  19. Ionic Liquids Beyond Simple Solvents: Glimpses at the State of the Art in Organic Chemistry

    PubMed Central

    Kuchenbuch, Andrea

    2015-01-01

    Abstract Within the last 25 years ionic liquids have written a tremendous success story, which is documented in a nearly uncountable amount of original research papers, reviews, and numerous applications in research and industry. These days, ionic liquids can be considered as a mature class of compounds for many different applications. Frequently, they are used as neoteric solvents for chemical tansformations, and the number of reviews on this field of research is huge. In this focused review, though, we are trying to evaluate the state of the art of ionic liquid chemistry beyond using them simply as solvents for chemical transformations. It is not meant to be a comprehensive overview on the topic; the choice of emphasis and examples rather refects the authors’ personal view on the field. We are especially highlighting fields in which we believe the most fundamental developments within the next five years will take place: biomass processing, (chiral) ionic liquids from natural sources, biotransformations, and organic synthesis. PMID:27308192

  20. The electro-structural behaviour of yarn-like carbon nanotube fibres immersed in organic liquids

    NASA Astrophysics Data System (ADS)

    Terrones, Jeronimo; Windle, Alan H.; Elliott, James A.

    2014-10-01

    Yarn-like carbon nanotube (CNT) fibres are a hierarchically-structured material with a variety of promising applications such as high performance composites, sensors and actuators, smart textiles, and energy storage and transmission. However, in order to fully realize these possibilities, a more detailed understanding of their interactions with the environment is required. In this work, we describe a simplified representation of the hierarchical structure of the fibres from which several mathematical models are constructed to explain electro-structural interactions of fibres with organic liquids. A balance between the elastic and surface energies of the CNT bundle network in different media allows the determination of the maximum lengths that open junctions can sustain before collapsing to minimize the surface energy. This characteristic length correlates well with the increase of fibre resistance upon immersion in organic liquids. We also study the effect of charge accumulation in open interbundle junctions and derive expressions to describe experimental data on the non-ohmic electrical behaviour of fibres immersed in polar liquids. Our analyses suggest that the non-ohmic behaviour is caused by progressively shorter junctions collapsing as the voltage is increased. Since our models are not based on any property unique to carbon nanotubes, they should also be useful to describe other hierarchical structures.

  1. Neutron spectroscopy with scintillation detectors using wavelets

    NASA Astrophysics Data System (ADS)

    Hartman, Jessica

    The purpose of this research was to study neutron spectroscopy using the EJ-299-33A plastic scintillator. This scintillator material provided a novel means of detection for fast neutrons, without the disadvantages of traditional liquid scintillation materials. EJ-299-33A provided a more durable option to these materials, making it less likely to be damaged during handling. Unlike liquid scintillators, this plastic scintillator was manufactured from a non-toxic material, making it safer to use, as well as easier to design detectors. The material was also manufactured with inherent pulse shape discrimination abilities, making it suitable for use in neutron detection. The neutron spectral unfolding technique was developed in two stages. Initial detector response function modeling was carried out through the use of the MCNPX Monte Carlo code. The response functions were developed for a monoenergetic neutron flux. Wavelets were then applied to smooth the response function. The spectral unfolding technique was applied through polynomial fitting and optimization techniques in MATLAB. Verification of the unfolding technique was carried out through the use of experimentally determined response functions. These were measured on the neutron source based on the Van de Graff accelerator at the University of Kentucky. This machine provided a range of monoenergetic neutron beams between 0.1 MeV and 24 MeV, making it possible to measure the set of response functions of the EJ-299-33A plastic scintillator detector to neutrons of specific energies. The response of a plutonium-beryllium (PuBe) source was measured using the source available at the University of Nevada, Las Vegas. The neutron spectrum reconstruction was carried out using the experimentally measured response functions. Experimental data was collected in the list mode of the waveform digitizer. Post processing of this data focused on the pulse shape discrimination analysis of the recorded response functions to remove the

  2. Cross-correlation measurements with the EJ-299-33 plastic scintillator

    NASA Astrophysics Data System (ADS)

    Bourne, Mark M.; Whaley, Jeff; Dolan, Jennifer L.; Polack, John K.; Flaska, Marek; Clarke, Shaun D.; Tomanin, Alice; Peerani, Paolo; Pozzi, Sara A.

    2015-06-01

    New organic-plastic scintillation compositions have demonstrated pulse-shape discrimination (PSD) of neutrons and gamma rays. We present cross-correlation measurements of 252Cf and mixed uranium-plutonium oxide (MOX) with the EJ-299-33 plastic scintillator. For comparison, equivalent measurements were performed with an EJ-309 liquid scintillator. Offline, digital PSD was applied to each detector. These measurements show that EJ-299-33 sacrifices a factor of 5 in neutron-neutron efficiency relative to EJ-309, but could still utilize the difference in neutron-neutron efficiency and neutron single-to-double ratio to distinguish 252Cf from MOX. These measurements were modeled with MCNPX-PoliMi, and MPPost was used to convert the detailed collision history into simulated cross-correlation distributions. MCNPX-PoliMi predicted the measured 252Cf cross-correlation distribution for EJ-309 to within 10%. Greater photon uncertainty in the MOX sample led to larger discrepancy in the simulated MOX cross-correlation distribution. The modeled EJ-299-33 plastic also gives reasonable agreement with measured cross-correlation distributions, although the MCNPX-PoliMi model appears to under-predict the neutron detection efficiency.

  3. New metal-organic nanomaterials synthesized by laser irradiation of organic liquids

    SciTech Connect

    Kuzmin, Stanislav L.; Wesolowski, Michal J.; Duley, Walter W.

    2014-03-31

    A new type of metal-organic composition consisting of clusters of nanoparticles has been synthesised by laser irradiation of metallocene/benzene solutions. The metallocene molecules in this reaction become the source of the metal. Exposure to high-energy femtosecond laser pulses dehydrogenate benzene molecules and initiate the high-temperature high-pressure conditions that results in the synthesis of new materials. Irradiation experiments have been carried out on ferrocene/benzene and on other solutions. With ferrocene the synthesis of a new compound has been confirmed by X-ray powder diffraction as the peaks detected do not correspond to any known substance in the Crystallography Open Database. Theoretical simulation of the periodic structure of this new carbide predicts that it has hexagonal symmetry and a unit cell with a = 3.2A and c =2.8A. The exact structure is still uncertain but may be determined from scanning tunneling microscope (STM) studies.

  4. Direct Observation of Self-Organized Water-Containing Structures in the Liquid Phase and Their Influence on 5-(Hydroxymethyl)furfural Formation in Ionic Liquids.

    PubMed

    Kashin, Alexey S; Galkin, Konstantin I; Khokhlova, Elena A; Ananikov, Valentine P

    2016-02-01

    Water-containing organic solutions are widespread reaction media in organic synthesis and catalysis. This type of multicomponent liquid system has a number of unique properties because of the tendency for water to self-organize in mixtures with other liquids. The characterization of these water domains is a challenging task because of their soft and dynamic nature. In the present study, the morphology and dynamics of micrometer- and nanometer-scale water-containing compartments in ionic liquids were directly observed by electron microscopy. A variety of morphologies, including isolated droplets, dense structures, aggregates, and 2D meshworks, have been experimentally detected and studied. Using the developed method, the impact of water on the acid-catalyzed biomass conversion reaction was studied at the microscopic level. The process that produced nanostructured domains in solution led to better yields and higher selectivities compared with reactions involving the bulk system. PMID:26754786

  5. LABORATORY INVESTIGATION OF RESIDUAL LIQUID ORGANICS FROM SPILLS, LEAKS, AND THE DISPOSAL OF HAZARDOUS WASTES IN GROUNDWATER

    EPA Science Inventory

    Organic liquids that are essentially immiscible with water migrate through the subsurface through the influence of capillary, viscous and buoyancy forces. Four experimental methods were employed. First, quantitative displacement experiments using short soil columns; second, add...

  6. LABORATORY INVESTIGATION OF RESIDUAL LIQUID ORGANICS FROM SPILLS, LEAKS, AND THE DISPOSAL OF HAZARDOUS WASTES IN GROUNDWATER

    EPA Science Inventory

    Organic liquids that are essentially immiscible with water migrate through the subsurface through the influence of capillary, viscous and buoyancy forces. our experimental methods were employed. irst, quantitative displacement experiments using short soil columns; second, additio...

  7. Aza-crown ether complex cation ionic liquids: preparation and applications in organic reactions.

    PubMed

    Song, Yingying; Cheng, Chen; Jing, Huanwang

    2014-09-26

    Aza-crown ether complex cation ionic liquids (aCECILs) were devised, fabricated, and characterized by using NMR spectroscopy, MS, thermogravimetric differential thermal analysis (TG-DTA), elemental analysis and physical properties. These new and room-temperature ILs were utilized as catalysts in various organic reactions, such as the cycloaddition reaction of CO2 to epoxides, esterification of acetic acid and alcohols, the condensation reaction of aniline and propylene carbonate, and Friedel-Crafts alkylation of indole with aldehydes were investigated carefully. In these reactions, the ionic liquid exhibited cooperative catalytic activity between the anion and cation. In addition, the aza-[18-C-6HK][HSO4]2 was the best acidic catalyst in the reactions of esterification and Friedel-Crafts alkylation under mild reaction conditions. PMID:25154312

  8. Photogeneration and enhanced charge transport in aligned smectic liquid crystalline organic semiconductor

    NASA Astrophysics Data System (ADS)

    Paul, Sanjoy; Ellman, Brett; Tripathi, Suvagata; Twieg, Robert J.

    2015-10-01

    Liquid crystalline organic semiconductors are emerging candidates for applications in electronic and photonic devices. One of the most attractive aspects of such materials is the potential, in principle, to easily control and manipulate the molecular alignment of the semiconductor over large length scales. Here, we explore the consequences of alignment in a model smectic liquid crystalline semiconductor, and find that the photogeneration efficiency is a strong function of incident polarization in aligned samples. A straightforward theory shows that such behavior is a general feature of aligned materials, regardless of the details of photophysics. Furthermore, we uncover tentative evidence that the mobility of aligned samples is substantially enhanced. Both of these phenomena are of significant technological importance.

  9. Photogeneration and enhanced charge transport in aligned smectic liquid crystalline organic semiconductor

    SciTech Connect

    Paul, Sanjoy; Ellman, Brett; Tripathi, Suvagata; Twieg, Robert J.

    2015-10-07

    Liquid crystalline organic semiconductors are emerging candidates for applications in electronic and photonic devices. One of the most attractive aspects of such materials is the potential, in principle, to easily control and manipulate the molecular alignment of the semiconductor over large length scales. Here, we explore the consequences of alignment in a model smectic liquid crystalline semiconductor, and find that the photogeneration efficiency is a strong function of incident polarization in aligned samples. A straightforward theory shows that such behavior is a general feature of aligned materials, regardless of the details of photophysics. Furthermore, we uncover tentative evidence that the mobility of aligned samples is substantially enhanced. Both of these phenomena are of significant technological importance.

  10. CO2-binding Organic Liquids, an Integrated Acid Gas Capture System

    SciTech Connect

    Heldebrant, David J; Koech, Phillip K; Rainbolt, James E; Zheng, Feng

    2011-04-01

    Amine systems are effective for CO2 capture, but they are still inefficient because the solvent regeneration energy is largely defined by the amount of water in the process. Most amines form heat-stable salts with SO2 and COS resulting in parasitic solvent loss and degradation. Stripping the CO2-rich solvent is energy intensive it requires temperatures above 100 °C due to the high specific heat and heat of vaporization of water. CO2-capture processes could be much more energy efficient in a water free amine process. In addition, if the capture-material is chemically compatible with other acid gases, less solvent would be lost to heat-stable salts and the process economics would be further improved. One such system that can address these concerns is Binding Organic Liquids (BOLs), a class of switchable ionic liquids.

  11. Nature-inspired light-harvesting liquid crystalline porphyrins for organic photovoltaics

    SciTech Connect

    Li, Lanfang; Kang, Shin-Woong; Harden, John; Sun, Qingjiang; Zhou, Xiaoli; Dai, Liming; Jakli, Antal; Kumar, Satyendra; Li, Quan

    2008-12-22

    A new class of nanoscale light-harvesting discotic liquid crystalline porphyrins, with the same basic structure of the best photoreceptor in nature (chlorophyll), was synthesized. These materials can be exceptionally aligned into a highly ordered architecture in which the columns formed by intermolecular {pi}-{pi} stacking are spontaneously perpendicular to the substrate. The homeotropic alignment, well confirmed by synchrotron X-ray diffraction, could not only provide the most efficient pathway for hole conduction along the columnar axis crossing the device thickness, but also offer the largest area to the incident light for optimized light harvesting. Their preliminary photocurrent generation and photovoltaic performances were also demonstrated. The results provide new and efficient pathways to the development of organic photovoltaics by using homeotropically aligned liquid crystal thin films.

  12. Self-organization processes and topological defects in nanolayers in a nematic liquid crystal

    SciTech Connect

    Chuvyrov, A. N.; Girfanova, F. M. Mal'tsev, I. S.

    2008-05-15

    Atomic force microscopy is used to study the self-organization processes that occur during the formation of topological defects in nanomolecular layers in a nematic liquid crystal with the homeotropic orientation of its molecules with respect to the substrate. In this case, a smectic monolayer with a thickness of one molecule length (about 2.2 nm) forms on the substrate, and a nanomolecular layer of a nematic liquid crystal forms above this monolayer. In such virtually two-dimensional layers, numerous different nanoclusters, namely, hut structures, pyramids, raft structures with symmetry C{sub nm} (where n = 2, 4, 5, 6, 7, ?, {infinity}), cones, and nanopools, form [1]. They have a regular shape close to the geometry of solid crystals. Modulated linear structures and topological point defects appear spontaneously in the nanopools and raft structures.

  13. Ionic liquid assisted hydrothermal fabrication of hierarchically organized γ-AlOOH hollow sphere

    SciTech Connect

    Tang, Zhe; Liu, Yunqi; Li, Guangci; Hu, Xiaofu; Liu, Chenguang

    2012-11-15

    Highlights: ► The γ-AlOOH hollow spheres were synthesized via an ionic liquid-assisted hydrothermal treatment. ► Ionic liquid plays an important role in the morphology of the product. ► Ionic liquid can be easily removed from the product and reused in next experiment. ► A “aggregation–solution–recrystallization” formation mechanism may occur in the system. -- Abstract: Hierarchically organized γ-AlOOH hollow spheres with nanoflake-like porous surface texture have been successfully synthesized via an ionic liquid-assisted hydrothermal synthesis method in citric acid monohydrate (CAMs). It was found that ionic liquid [bmim]{sup +}Cl{sup −} played an important role in the morphology of the product due to its strong interactions with reaction particles. The samples were characterized by X-ray Diffraction (XRD), Fourier Transform Infrared Spectroscopy (FT-IR), Scanning Electron Microscope (SEM) and Transmission Electron Microscopy (TEM). The results show that the product has narrow particle size distribution (500–900 nm particle diameter range), high specific surface area (240.5 m{sup 2}/g) and large pore volume (0.61 cm{sup 3}/g). The corresponding γ-Al{sub 2}O{sub 3} hollow spheres can be obtained by calcining it at 550 °C for 3 h. The proposed formation mechanism and other influencing factors of the γ-AlOOH hollow sphere material, such as reaction temperature, reaction duration, CAMs and urea, have also been investigated.

  14. Study of nanostructural organization of ionic liquids by electron paramagnetic resonance spectroscopy.

    PubMed

    Merunka, Dalibor; Peric, Mirna; Peric, Miroslav

    2015-02-19

    The X-band electron paramagnetic resonance spectroscopy (EPR) of a stable, spherical nitroxide spin probe, perdeuterated 2,2,6,6-tetramethyl-4-oxopiperidine-1-oxyl (pDTO) has been used to study the nanostructural organization of a series of 1-alkyl-3-methylimidazolium tetrafluoroborate ionic liquids (ILs) with alkyl chain lengths from two to eight carbons. By employing nonlinear least-squares fitting of the EPR spectra, we have obtained values of the rotational correlation time and hyperfine coupling splitting of pDTO to high precision. The rotational correlation time of pDTO in ILs and squalane, a viscous alkane, can be fit very well to a power law functionality with a singular temperature, which often describes a number of physical quantities measured in supercooled liquids. The viscosity of the ILs and squalane, taken from the literature, can also be fit to the same power law expression, which means that the rotational correlation times and the ionic liquid viscosities have similar functional dependence on temperature. The apparent activation energy of both the rotational correlation time of pDTO and the viscous flow of ILs and squalane increases with decreasing temperature; in other words, they exhibit strong non-Arrhenius behavior. The rotational correlation time of pDTO as a function of η/T, where η is the shear viscosity and T is the temperature, is well described by the Stokes-Einstein-Debye (SED) law, while the hydrodynamic probe radii are solvent dependent and are smaller than the geometric radius of the probe. The temperature dependence of hyperfine coupling splitting is the same in all four ionic liquids. The value of the hyperfine coupling splitting starts decreasing with increasing alkyl chain length in the ionic liquids in which the number of carbons in the alkyl chain is greater than four. This decrease together with the decrease in the hydrodynamic radius of the probe indicates a possible existence of nonpolar nanodomains. PMID:25594422

  15. Self-organization of jets in electrospinning from free liquid surface: A generalized approach

    NASA Astrophysics Data System (ADS)

    Lukas, David; Sarkar, Arindam; Pokorny, Pavel

    2008-04-01

    Electrospinning has enabled creation of excellent materials for a great number of applications. Previously, it was based on less productive capillary spinners. The present study is based on recent efforts to elevate electrospinning technology to an industrial level by simultaneously provoking innumerable polymeric jets from a sufficiently large liquid surface to increase productivity. Particularly, it deals with electrospinning from free surface of conductive liquids and validates a formulated hypothesis that explains self-organization of jets on one-dimensional free liquid surfaces in terms of electrohydrodynamic instability of surface waves. Here, it is shown how the hypothesis, based on a profound analysis of a dispersion law, explains that above a certain critical value of applied electric field intensity/field strength the system starts to be self-organized in mesocopic scale due to the mechanism of the "fastest forming instability." The mechanism plays a key role in selecting a particular wave with a characteristic wavelength whose amplitude boundlessly grows faster than the others. The fastest growing stationary wave, according to the hypothesis, marks the onset of electrospinning from a free liquid surface with its jets originating from the wave crests. Singularity of this approach lies in predicting critical values of the phenomenon, viz., critical field strength and corresponding critical interjet distance. The critical field strength, will, thereafter, be used in defining a unique dimensionless electrospinning number. It will, subsequently, be shown how the critical interjet distance, i.e., the maximal distance between the neighboring jets, simply depends on the capillary length. The capillary length represents a latent characteristic spatial scale of the system. The theory also predicts interjet distance for field strengths above the critical value. The said prediction is universally applicable for all conductive liquids if it is expressed in terms of

  16. Liquid- and Ice-Phase Kinetics of Singlet Molecular Oxygen with Organic Pollutants

    NASA Astrophysics Data System (ADS)

    Bower, J. P.; Anastasio, C.

    2012-12-01

    Singlet molecular oxygen (1O2*), a reactive state of dissolved oxygen, is formed from a sensitizer chromophore that absorbs light and transfers energy to ground-state O2. The chemistry of 1O2* has been studied predominantly in surface waters and aqueous atmospheric drops, where 1O2* can be an important sink for electron-rich pollutants. In our recent work we have shown that 1O2* concentrations can be enhanced by several orders of magnitude on ice compared to in identical, but unfrozen, aqueous solutions. The goal of this work is to assess the potential importance of 1O2* to the decay of organic pollutants on ice in order to better understand pollutant cycling in the cryosphere. Using 549 nm radiation we illuminated liquid and bulk ice samples containing a 1O2* sensitizer (Rose Bengal), salt (NaCl), and an organic pollutant at a controlled temperature. Organic species were chosen to represent several chemical classes, including furans (furfuryl alcohol), phenols (bisphenol A), and amino acids (tryptophan). During illumination the decay of the pollutant was measured to determine the rate constant for loss by reaction with 1O2*. In all cases we observe enhanced loss of pollutants on ice relative to liquid samples. We will discuss how the magnitude of the ice-phase enhancement depends on the different pollutant classes, their aqueous solubility, and freezing point depression.

  17. Organics Produced by Irradiation of Frozen and Liquid HCN Solutions: Implications for Chemical Evolution Studies

    NASA Astrophysics Data System (ADS)

    Colín-García, M.; Negrón-Mendoza, A.; Ramos-Bernal, S.

    2009-04-01

    Hydrogen cyanide (HCN), an important precursor of organic compounds, is widely present in extraterrestrial environments. HCN is also readily synthesized in prebiotic simulation experiments. To gain insight into the radiation chemistry of one of the most important and highly versatile constituents of cometary ices, we examined the behavior of over-irradiated frozen and liquid HCN solutions under ionizing radiation. The samples were exposed to gamma radiation at a dose range from 0 up to 419 kGy. Ultraviolet spectroscopy and gas chromatography were used to follow the process. The analyses confirmed that gamma-ray irradiation of liquid HCN solutions generates several organic products. Many of them are essential to life; we verified the presence of carboxylic acids (some of them members of the Krebs cycle) as well as free amino acids and urea. These are the first studies to reveal the presence of these compounds in experiments performed at low temperatures and bulk irradiation. Organic material was produced even at low temperatures and low radiation doses. This work strongly supports the presumption that, as a parent molecule, HCN played a central essential role in the process of chemical evolution on early Earth, comets, and other extraterrestrial environments.

  18. Composite scintillator screen

    DOEpatents

    Zeman, Herbert D.

    1994-01-01

    A scintillator screen for an X-ray system includes a substrate of low-Z material and bodies of a high-Z material embedded within the substrate. By preselecting the size of the bodies embedded within the substrate, the spacial separation of the bodies and the thickness of the screen, the sensitivity of the screen to X-rays within a predetermined energy range can be predicted.

  19. A scintillating fission detector for neutron flux measurements

    SciTech Connect

    Stange, Sy; Esch, Ernst I; Burgett, Eric A; May, Iain; Muenchausen, Ross E; Taw, Felicia; Tovesson, Fredrik K

    2010-01-01

    Neutron flux monitors are commonly used for a variety of nuclear physics applications. A scintillating neutron detector, consisting of a liquid scintillator loaded with fissionable material, has been developed, characterized, and tested in the beam line at the Los Alamos Neutron Science Center, and shows a significant improvement in neutron sensitivity compared with a conventional fission chamber. Recent research on nanocomposite-based scintillators for gamma-ray detection indicates that this approach can be extended to load nanoparticles of fissionable material into a scintillating matrix, with up to three orders of magnitude higher loading than typical fission chambers. This will result in a rugged, cost-efficient detector with high efficiency, a short signal rise time, and the ability to be used in low neutron-flux environments. Initial efforts to utilize the luminescence of uranyl oxide to eliminate the need for wavelength-shifting dyes were unsuccessful. Excitation of uranyl compounds has been reported at wavelengths ranging from 266 nm to 532 nm. However, neither the 300 nm emission of toluene, nor the 350 nm emission of PPO, nor the 410 nm emission of POPOP resulted in significant excitation of and emission by uranyl oxide. As indicated by UV/visible spectroscopy, light emitted at these wavelengths was absorbed by the colored solution. {sup 235}U remains the most attractive candidate for a fissionable scintillator, due to its high fission cross-section and lack of a threshold fission energy, but all solutions containing molecular uranium compounds will be colored, most more highly than the U{sup 6+} compounds used here. Research is therefore continuing toward the fabrication of uranium nanoparticles, in which, due to Rayleigh scattering, the coloration should be less pronounced. The characterization of the thorium-loaded liquid scintillator and the fabrication of the 100 mL detectors for use at LANSCE demonstrated the feasibility of loading fissionable

  20. Spatially resolved charge transport study in discotic liquid crystalline organic semiconductors

    NASA Astrophysics Data System (ADS)

    Paul, Sanjoy; Semyonov, Alexander; Dawson, Nathan J.; Singer, Kenneth D.; Twieg, Robert J.; Ellman, Brett

    Spatially resolved time-of-flight photogeneration and mobility have been measured on a discotic liquid crystalline organic semiconductor using scanning time-of-flight microscopy (STOFm). STOFm simultaneously obtains time-of-flight transients and polarized transmittance across the sample. Various shapes in time-of-flight transients were observed and extracted charge transport parameters such as photogeneration efficiency, mobility, and trapping show significant spatial variation. In some cases these can be linked to electrode surface inhomogeneities. Detailed measurement methodology, experimental results and challenges in their analysis will be discussed.

  1. Nanophosphor composite scintillators comprising a polymer matrix

    DOEpatents

    Muenchausen, Ross Edward; Mckigney, Edward Allen; Gilbertson, Robert David

    2010-11-16

    An improved nanophosphor composite comprises surface modified nanophosphor particles in a solid matrix. The nanophosphor particle surface is modified with an organic ligand, or by covalently bonding a polymeric or polymeric precursor material. The surface modified nanophosphor particle is essentially charge neutral, thereby preventing agglomeration of the nanophosphor particles during formation of the composite material. The improved nanophosphor composite may be used in any conventional scintillator application, including in a radiation detector.

  2. One-step synthesis of layered yttrium hydroxides in immiscible liquid-liquid systems: Intercalation of sterically-bulky hydrophobic organic anions and doping of europium ions

    NASA Astrophysics Data System (ADS)

    Watanabe, Mebae; Fujihara, Shinobu

    2014-02-01

    Inorganic-organic layered rare-earth compounds were synthesized on the basis of a biphasic liquid-liquid system in one pot. Layered yttrium hydroxides (LYHs) were chosen as a host material for the intercalation of hydrophobic organic guest anions such as benzoate, sebacate, or laurate. In a typical synthesis, an organic phase dissolving carboxylic acid was placed in contact with an equal amount of an aqueous phase dissolving yttrium nitrate n-hydrate and urea. At elevated temperatures up to 80 °C, urea was hydrolyzed to release hydroxyl anions which were used to form yttrium hydroxide layers. LYHs were then precipitated with the intercalation of carboxylate anions delivered from the organic phase under the distribution law. The structure and the morphology of the LYHs could be modulated by the intercalated anions. Doped with Eu3+ ions, the LYHs exhibited red photoluminescence which was enhanced by the intercalated anions due to the antenna effect.

  3. Aqueous liquid feed organic fuel cell using solid polymer electrolyte membrane

    NASA Technical Reports Server (NTRS)

    Surampudi, Subbarao (Inventor); Narayanan, Sekharipuram R. (Inventor); Vamos, Eugene (Inventor); Frank, Harvey A. (Inventor); Halpert, Gerald (Inventor); Olah, George A. (Inventor); Prakash, G. K. Surya (Inventor)

    1997-01-01

    A liquid organic fuel cell is provided which employs a solid electrolyte membrane. An organic fuel, such as a methanol/water mixture, is circulated past an anode of a cell while oxygen or air is circulated past a cathode of the cell. The cell solid electrolyte membrane is preferably fabricated from Nafion.TM.. Additionally, a method for improving the performance of carbon electrode structures for use in organic fuel cells is provided wherein a high surface-area carbon particle/Teflon.TM.-binder structure is immersed within a Nafion.TM./methanol bath to impregnate the electrode with Nafion.TM.. A method for fabricating an anode for use in a organic fuel cell is described wherein metal alloys are deposited onto the electrode in an electro-deposition solution containing perfluorooctanesulfonic acid. A fuel additive containing perfluorooctanesulfonic acid for use with fuel cells employing a sulfuric acid electrolyte is also disclosed. New organic fuels, namely, trimethoxymethane, dimethoxymethane, and trioxane are also described for use with either conventional or improved fuel cells.

  4. A scintillator purification system for the Borexino solar neutrino detector

    NASA Astrophysics Data System (ADS)

    Benziger, J.; Cadonati, L.; Calaprice, F.; Chen, M.; Corsi, A.; Dalnoki-Veress, F.; Fernholz, R.; Ford, R.; Galbiati, C.; Goretti, A.; Harding, E.; Ianni, Aldo; Ianni, Andrea; Kidner, S.; Leung, M.; Loeser, F.; McCarty, K.; McKinsey, D.; Nelson, A.; Pocar, A.; Salvo, C.; Schimizzi, D.; Shutt, T.; Sonnenschein, A.

    2008-03-01

    Purification of the 278 tons of liquid scintillator and 889 tons of buffer shielding for the Borexino solar neutrino detector is performed with a system that combines distillation, water extraction, gas stripping, and filtration. This paper describes the principles of operation, design, and construction of that purification system, and reviews the requirements and methods to achieve system cleanliness and leak-tightness.

  5. New scintillator and waveshifter materials

    SciTech Connect

    Zheng, H.; Baumbaugh, B.; Gerig, A.; Marchant, J.; Reynolds, K.; Ruchti, R.; Warchol, J; Wayne, M. Hurlbut, C. Kauffman, J. Pla-Dalmau, A.

    1998-11-01

    Experimental applications requiring fast timing and/or high efficiency position and energy measurements typically use scintillation materials. Scintillators utilized for triggering, tracking, and calorimetry in colliding beam detectors are vulnerable to the high radiation fields associated with such experiments. We have begun an investigation of several fluorescent dyes which might lead to fast, efficient, and radiation resistant scintillators. Preliminary results of spectral analysis and efficiency are presented. {copyright} {ital 1998 American Institute of Physics.}

  6. Lunar components in Lunping scintillations

    SciTech Connect

    Koster, J.R.; Lue, H.Y.; Wu, Hsi-Shu; Huang, Yinn-Nien

    1993-08-01

    The authors report on an anlysis of a 14 year data set of ionospheric scintillation data for 136 MHz signals transmitted from a Japanese satellite. They use a lunar age superposition method to analyze this data, breaking the data into blocks by seasons of the year. They observe a number of different scintillation types in the record, as well as impacts of lunar tides on the time record. They attempt to provide an origin for the different scintillation types.

  7. Mass transfer from nonaqueous phase organic liquids in water-saturated porous media

    SciTech Connect

    Geller, J.T. ); Hunt, J.R. )

    1993-04-01

    The widespread production and use of industrial solvents and liquid petroleum products have provided ample opportunity for subsurface contamination from leaking underground storage tanks and pipelines, hazardous waste sites, and surface spills. The aqueous solubility of these organic liquid contaminants is low enough for them to exist in the subsurface as nonaqueous phase liquids (NAPLs) but large enough to seriously degrade water quality. In this paper, results from measuring the complete dissolution of trapped NAPLs and developing a model are discussed. The NAPL saturation is modeled as discrete spheres that are initially uniform in size. From the experimental data, ganglia size and the cross-sectional area of the NAPL region are obtained by fitting the model to the data and assuming a fixed initial NAPL saturation. This two-parameter model, when combined with known magnitudes of residual saturation and relative permeability functions represented experimental observations of (1) increasing aqueous concentration during initial water flooding as the mass transfer zone is established, (2) a quasi-steady effluent concentration as the mass transfer zone propagates downstream, and (3) the decline in effluent concentration as the NAPL-containing region shrinks to less than the length of the mass transfer zone. The experimental data and modeling effort illustrate mechanisms that limit the remediation of NAPL-contaminated aquifers. There is a complex dependency of groundwater contaminant concentration on flow velocity.

  8. Nondisruptive Dissolution of Hyperpolarized (129)Xe into Viscous Aqueous and Organic Liquid Crystalline Environments.

    PubMed

    Truxal, Ashley E; Slack, Clancy C; Gomes, Muller D; Vassiliou, Christophoros C; Wemmer, David E; Pines, Alexander

    2016-04-01

    Studies of hyperpolarized xenon-129 (hp-(129)Xe) in media such as liquid crystals and cell suspensions are in demand for applications ranging from biomedical imaging to materials engineering but have been hindered by the inability to bubble Xe through the desired media as a result of viscosity or perturbations caused by bubbles. Herein a device is reported that can be reliably used to dissolve hp-(129)Xe into viscous aqueous and organic samples without bubbling. This method is robust, requires small sample volumes (<60 μL), is compatible with existing NMR hardware, and is made from readily available materials. Experiments show that Xe can be introduced into viscous and aligned media without disrupting molecular order. We detected dissolved xenon in an aqueous liquid crystal that is disrupted by the shear forces of bubbling, and we observed liquid-crystal phase transitions in (MBBA). This tool allows an entirely new class of samples to be investigated by hyperpolarized-gas NMR spectroscopy. PMID:26954536

  9. Apparatus and methods for determining gas saturation and porosity of a formation penetrated by a gas filled or liquid filled borehole

    SciTech Connect

    Wilson, Robert D.

    2001-03-27

    Methods and apparatus are disclosed for determining gas saturation, liquid saturation, porosity and density of earth formations penetrated by a well borehole. Determinations are made from measures of fast neutron and inelastic scatter gamma radiation induced by a pulsed, fast neutron source. The system preferably uses two detectors axially spaced from the neutron source. One detector is preferably a scintillation detector responsive to gamma radiation, and a second detector is preferably an organic scintillator responsive to both neutron and gamma radiation. The system can be operated in cased boreholes which are filled with either gas or liquid. Techniques for correcting all measurements for borehole conditions are disclosed.

  10. OPTIMIZED DETERMINATION OF TRACE JET FUEL VOLATILE ORGANIC COMPOUNDS IN HUMAN BLOOD USING IN-FIELD LIQUID-LIQUID EXTRACTION WITH SUBSEQUENT LABORATORY GAS CHROMATOGRAPHIC-MASS SPECTROMETRIC ANALYSIS AND ON-COLUMN LARGE VOLUME INJECTION

    EPA Science Inventory

    A practical and sensitive method to assess volatile organic compounds (VOCs) from JP-8 jet fuel in human whole blood was developed by modifying previously established liquid-liquid extraction procedures, optimizing extraction times, solvent volume, specific sample processing te...

  11. Statistical analysis of scintillation data

    SciTech Connect

    Chua, S.; Noonan, J.P.; Basu, S.

    1981-09-01

    The Nakagami-m distribution has traditionally been used successfully to model the probability characteristics of ionospheric scintillations at UHF. This report investigates the distribution properties of scintillation data in the L-band range. Specifically, the appropriateness of the Nakagami-m and lognormal distributions is tested. Briefly the results confirm that the Nakagami-m is appropriate for UHF but not for L-band scintillations. The lognormal provides a better fit to the distribution of L-band scintillations and is an adequate model allowing for an error of + or - 0.1 or smaller in predicted probability with a sample size of 256.

  12. Detecting dark matter with scintillating bubble chambers

    NASA Astrophysics Data System (ADS)

    Zhang, Jianjie; Dahl, C. Eric; Jin, Miaotianzi; Baxter, Daniel

    2016-03-01

    Threshold based direct WIMP dark matter detectors such as the superheated bubble chambers developed by the PICO experiment have demonstrated excellent electron-recoil and alpha discrimination, excellent scalability, ease of change of target fluid, and low cost. However, the nuclear-recoil like backgrounds have been a limiting factor in their dark matter sensitivity. We present a new type of detector, the scintillating bubble chamber, which reads out the scintillation pulse of the scattering events as well as the pressure, temperature, acoustic traces, and bubble images as a conventional bubble chamber does. The event energy provides additional handle to discriminate against the nuclear-recoil like backgrounds. Liquid xenon is chosen as the target fluid in our prototyping detector for its high scintillation yield and suitable vapor pressure which simplifies detector complexity. The detector can be used as an R&D tool to study the backgrounds present in the current PICO bubble chambers or as a prototype for standalone dark matter detectors in the future. Supported by DOE Grant DE-SC0012161.

  13. Evaluating the Molecular Interaction of Organic Liquid Mixtures Using Near-Infrared Spectroscopy.

    PubMed

    Xiong, Zhixin; Pfeifer, Frank; Siesler, Heinz W

    2016-04-01

    The near-infrared transmission spectra of two organic liquid three-component systems of variable compositions were investigated in detail. To evaluate the interaction of the different components in the two systems the experimental spectra of the pure components were compared to mathematically constructed "pure component" spectra. Though usually the correlation coefficient (CC) and Manhattan distance (MD) are used to measure the similarity of spectra, in the present investigations principal component analysis (PCA) was found to be a more effective tool to investigate the difference between these spectra and derive parameters characterizing the interaction between the different components. Thus, PC scores for the two types of spectra established some distinct patterns which clearly expressed their differences. For a three-dimensional coordinate system of selected principal components, the Euclidean distances between the mathematically constructed and the experimental spectra of the pure components were calculated. Finally, the mean values of the distances for each component provided indices to rank the interaction of the components in the mixtures. Thus, the results offer a convenient approach that can quantitatively evaluate the molecular interactions of the individual components in organic liquid mixtures by various spectroscopies. PMID:26928223

  14. Macrophages Sequester Clofazimine in an Intracellular Liquid Crystal-Like Supramolecular Organization

    PubMed Central

    Baik, Jason; Rosania, Gus R.

    2012-01-01

    Clofazimine is a poorly-soluble but orally-bioavailable small molecule drug that massively accumulates in macrophages when administered over prolonged periods of time. To determine whether crystal-like drug inclusions (CLDIs) that form in subcellular spaces correspond to pure clofazimine crystals, macrophages of clofazimine-fed mice were elicited with an intraperitoneal thioglycollate injection. Inside these cells, CLDIs appeared uniform in size and shape, but were sensitive to illumination. Once removed from cells, CLDIs were unstable. Unlike pure clofazimine crystals, isolated CLDIs placed in distilled water burst into small birefringent globules, which aggregated into larger clusters. Also unlike pure clofazimine crystals, CLDIs fragmented when heated, and disintegrated in alkaline media. In contrast to all other organelles, CLDIs were relatively resistant to sonication and trypsin digestion, which facilitated their biochemical isolation. The powder x-ray diffraction pattern obtained from isolated CLDIs was consistent with the diffraction pattern of liquid crystals and inconsistent with the expected molecular diffraction pattern of solid, three dimensional crystals. Observed with the transmission electron microscope (TEM), CLDIs were bounded by an atypical double-layered membrane, approximately 20 nanometers thick. CLDIs were polymorphic, but generally exhibited an internal multilayered organization, comprised of stacks of membranes 5 to 15 nanometers thick. Deep-etch, freeze-fracture electron microscopy of unfixed snap-frozen tissue samples confirmed this supramolecular organization. These results suggest that clofazimine accumulates in macrophages by forming a membrane-bound, multilayered, liquid crystal-like, semi-synthetic cytoplasmic structure. PMID:23071814

  15. Marangoni Convection in Evaporating Organic Liquid Droplets on a Nonwetting Substrate.

    PubMed

    Chandramohan, Aditya; Dash, Susmita; Weibel, Justin A; Chen, Xuemei; Garimella, Suresh V

    2016-05-17

    We quantitatively characterize the flow field inside organic liquid droplets evaporating on a nonwetting substrate. A mushroom-structured surface yields the desired nonwetting behavior with methanol droplets, while use of a cooled substrate (5-15 °C) slows the rate of evaporation to allow quasi-static particle image velocimetry. Visualization reveals a toroidal vortex within the droplet that is characteristic of surface tension-driven flow; we demonstrate by means of a scaling analysis that this recirculating flow is Marangoni convection. The velocities in the droplet are on the order of 10-45 mm/s. Thus, unlike in the case of evaporation on wetting substrates where Marangoni convection can be ignored for the purpose of estimating the evaporation rate, advection due to the surface tension-driven flow plays a dominant role in the heat transfer within an evaporating droplet on a nonwetting substrate because of the large height-to-radius aspect ratio of the droplet. We formulate a reduced-order model that includes advective transport within the droplet for prediction of organic liquid droplet evaporation on a nonwetting substrate and confirm that the predicted temperature differential across the height of the droplet matches experiments. PMID:27119436

  16. The response of scintillators to heavy ions: 1, Plastics

    SciTech Connect

    McMahan, M.A.

    1987-10-01

    The response of various scintillator detectors to ions of A = 1-84 and energies E/A = 5 to 30 MeV have been measured, and are found to be linear above an energy of 100 MeV. Results are presented for a typical organic plastic scintillator including parametrizations of the data as a function of Z, A, and energy. These results can be used by anyone using scintillators as heavy ion detectors, with one calibration point giving a normalization that allows use of the whole set of curves. The response functions are compared to previous parametrizations at lower energies and discussed in terms of the theory of delta-ray formation in the scintillator.

  17. Silica scintillating materials prepared by sol-gel methods

    SciTech Connect

    Werst, D.W.; Sauer, M.C. Jr.; Cromack, K.R.; Lin, Y.; Tartakovsky, E.A.; Trifunac, A.D.

    1993-12-31

    Silica was investigated as a rad-hard alternative to organic polymer hosts for organic scintillators. Silica sol-gels were prepared by hydrolysis of tetramethoxysilane in alcohol solutions. organic dyes were incorporated into the gels by dissolving in methanol at the sol stage of gel formation. The silica sol-gel matrix is very rad-hard. The radiation stability of silica scintillators prepared by this method is dye-limited. Transient radioluminescence was measured following excitation with 30 ps pulses of 20 MeV electrons.

  18. Liquid-phase adsorption of organic compounds by granular activated carbon and activated carbon fibers

    SciTech Connect

    Lin, S.H.; Hsu, F.M.

    1995-06-01

    Liquid-phase adsorption of organic compounds by granular activated carbon (GAC) and activated carbon fibers (ACFs) is investigated. Acetone, isopropyl alcohol (IPA), phenol, and tetrahydrofuran (THF) were employed as the model compounds for the present study. It is observed from the experimental results that adsorption of organic compounds by GAC and ACF is influenced by the BET (Brunauer-Emmett-Teller) surface area of adsorbent and the molecular weight, polarity, and solubility of the adsorbate. The adsorption characteristics of GAC and ACFs were found to differ rather significantly. In terms of the adsorption capacity of organic compounds, the time to reach equilibrium adsorption, and the time for complete desorption, ACFs have been observed to be considerably better than GAC. For the organic compounds tested here, the GAC adsorptions were shown to be represented well by the Langmuir isotherm while the ACF adsorption could be adequately described by the Langmuir or the Freundlich isotherm. Column adsorption tests indicated that the exhausted ACFs can be effectively regenerated by static in situ thermal desorption at 150 C, but the same regeneration conditions do not do as well for the exhausted GAC.

  19. Organic solvents for pharmaceutical parenterals and embolic liquids: a review of toxicity data.

    PubMed

    Mottu, F; Laurent, A; Rufenacht, D A; Doelker, E

    2000-01-01

    Non-aqueous solvents have long been used in subcutaneous or intramuscular pharmaceutical formulations to dissolve water-insoluble drugs. In recent years, the need for these vehicles was increased since the drug discovery process has yielded many poorly water-soluble drugs. Besides, preparations containing embolic materials dissolved in undiluted non-aqueous water-miscible solvents have been proposed for the intravascular treatment of aneurysms, arteriovenous malformations, or tumors. These organic solvents, regarded as chemically and biologically inert, may show pharmacological and toxicological effects. Therefore, knowledge of tolerance and activity of non-aqueous solvents is essential before they can be administered, especially when given undiluted. This paper focuses on thirteen organic solvents reported as possible vehicles for injectable products and details toxicological data when they have been administered intravascularly. These solvents can be subdivided into three groups according to their description in the literature either for intravenous pharmaceutical parenterals or for intravascular embolic liquids: well-documented organic solvents (propylene glycol, polyethylene glycols, ethanol), solvents described in specific applications (dimethyl sulfoxide, N-methyl-2-pyrrolidone, glycofurol, Solketal, glycerol formal, acetone), and solvents not reported in intravascular applications but potentially useful (tetrahydrofurfuryl alcohol, diglyme, dimethyl isosorbide, ethyl lactate). This review of the literature shows that toxicity data on intravascular organic solvents are insufficient because they concern solvents diluted with water and because of the lack of comparative evaluation using the same methodologies. PMID:11107838

  20. Organic solvents induce the formation of oil-in-ionic liquid microemulsion aggregations.

    PubMed

    Gao, Yanan; Li, Na; Zhang, Shaohua; Zheng, Liqiang; Li, Xinwei; Dong, Bin; Yu, Li

    2009-02-01

    The role of four organic solvents in the formation process of 1-butyl-3-methylimidazolium tetrafluoroborate (bmimBF4) based ionic liquid (IL) microemulsions is investigated. The results showed that the addition of Triton X-100 remarkably decreased the conductivity of bmimBF4. The added organic solvents provided a strong apolar environment for the hydrophobic tails of Triton X-100 and caused the surfactant molecules to aggregate into the interfacial film of oil-in-bmimBF4 (O/IL) microemulsions. As a result, the conductivities of the solutions were initially increased because the insulative Triton X-100 molecules were assembled, which corresponded to increasing the concentration of continuous bmimBF4 solutions. The hydrophobic interaction between the dispersed organic solvents and the hydrophobic tails of Triton X-100 may be the driving force for the formation of O/IL microemulsions. The droplets of O/IL microemulsions were successively swollen by organic solvents, and a bicontinuous IL-containing microemulsion was observed by freeze-fracture transmission electron microscopy for the first time. The current study can help in further understanding the ILs-containing microemulsions and thereby improve microemulsion theory. PMID:19138136