Science.gov

Sample records for mass spectrometry supercritical

  1. Supercritical fluid extraction as a preparation method for mass spectrometry of dried blood spots.

    PubMed

    Matsubara, Atsuki; Izumi, Yoshihiro; Nishiumi, Shin; Suzuki, Makoto; Azuma, Takeshi; Fukusaki, Eiichiro; Bamba, Takeshi; Yoshida, Masaru

    2014-10-15

    The potential of supercritical fluid extraction (SFE) as a preparation method for mass spectrometry of dried blood spots (DBS) was examined. SFE is generally used for the extraction of hydrophobic compounds, but hydrophilic metabolites such as amino acids, amines, and nucleic-acid-related metabolites could be extracted by adding a low level of methanol as a modifier. Under the optimized conditions, over 200 metabolites were detected from a dried serum spot, of which over 160 metabolites could be analyzed stably (RSD <20%). These results show that SFE is an effective extraction method of metabolites with a wide range of polarity in DBS. PMID:25178194

  2. Coal liquefaction process streams characterization and evaluation. Characterization of coal-derived materials by field desorption mass spectrometry, two-dimensional nuclear magnetic resonance, supercritical fluid extraction, and supercritical fluid chromatography/mass spectrometry

    SciTech Connect

    Campbell, J.A.; Linehan, J.C.; Robins, W.H.

    1992-07-01

    Under contract from the DOE , and in association with CONSOL Inc., Battelle, Pacific Northwest Laboratory (PNL) evaluated four principal and several complementary techniques for the analysis of non-distillable direct coal liquefaction materials in support of process development. Field desorption mass spectrometry (FDMS) and nuclear magnetic resonance (NMR) spectroscopic methods were examined for potential usefulness as techniques to elucidate the chemical structure of residual (nondistillable) direct coal liquefaction derived materials. Supercritical fluid extraction (SFE) and supercritical fluid chromatography/mass spectrometry (SFC/MS) were evaluated for effectiveness in compound-class separation and identification of residual materials. Liquid chromatography (including microcolumn) separation techniques, gas chromatography/mass spectrometry (GC/MS), mass spectrometry/mass spectrometry (MS/MS), and GC/Fourier transform infrared (FTIR) spectroscopy methods were applied to supercritical fluid extracts. The full report authored by the PNL researchers is presented here. The following assessment briefly highlights the major findings of the project, and evaluates the potential of the methods for application to coal liquefaction materials. These results will be incorporated by CONSOL into a general overview of the application of novel analytical techniques to coal-derived materials at the conclusion of CONSOL`s contract.

  3. Fast separation of triterpenoid saponins using supercritical fluid chromatography coupled with single quadrupole mass spectrometry.

    PubMed

    Huang, Yang; Zhang, Tingting; Zhou, Haibo; Feng, Ying; Fan, Chunlin; Chen, Weijia; Crommen, Jacques; Jiang, Zhengjin

    2016-03-20

    Triterpenoid saponins (TSs) are the most important components of some traditional Chinese medicines (TCMs) and have exhibited valuable pharmacological properties. In this study, a rapid and efficient method was developed for the separation of kudinosides, stauntosides and ginsenosides using supercritical fluid chromatography coupled with single quadrupole mass spectrometry (SFC-MS). The separation conditions for the selected TSs were carefully optimized after the initial screening of eight stationary phases. The best compromise for all compounds in terms of chromatographic performance and MS sensitivity was obtained when water (5-10%) and formic acid (0.05%) were added to the supercritical carbon dioxide/MeOH mobile phase. Beside the composition of the mobile phase, the nature of the make-up solvent for interfacing SFC with MS was also evaluated. Compared to reversed phase liquid chromatography, the SFC approach showed higher resolution and shorter running time. The developed SFC-MS methods were successfully applied to the separation and identification of TSs present in Ilex latifolia Thunb., Panax quinquefolius L. and Panax ginseng C.A. Meyer. These results suggest that this SFC-MS approach could be employed as a useful tool for the quality assessment of natural products containing TSs as active components. PMID:26773536

  4. High-throughput simultaneous analysis of pesticides by supercritical fluid chromatography/tandem mass spectrometry.

    PubMed

    Ishibashi, Megumi; Ando, Takashi; Sakai, Miho; Matsubara, Atsuki; Uchikata, Takato; Fukusaki, Eiichiro; Bamba, Takeshi

    2012-11-30

    Combination techniques such as gas chromatography/mass spectrometry (GC/MS) and liquid chromatography/mass spectrometry (LC/MS) are commonly used for pesticide residue analysis, but there is no reported method for the simultaneous analysis of multiple pesticides in a sample using a single instrument. Supercritical fluid chromatography (SFC) offers high resolution at high flow rates and various separation modes and hence may aid the rapid simultaneous analysis of pesticide. We developed an SFC/MS/MS method and analyzed 17 pesticides with a wide range of polarities (logP(ow)=-4.6 to 7.05) and molecular weights (112.1-888.6) within 11min using a polar-embedded reversed-phase column. To the best of our knowledge, there is no previous report on the SFC analysis of a wide variety of compounds, including highly hydrophilic ones. By SFC, diquat dibromide (logP(ow)=-4.6), together with cypermethrin (logP(ow)=6.6) and tralomethrin (logP(ow)=5.05), could be detected in the presence of various other pesticides using a single mobile phase. SFC/MS allows for the rapid and simultaneous analysis of low concentrations (ng/L levels) of pesticides that typically need to be analyzed by GC/MS and LC/MS separately. PMID:23102524

  5. MEASUREMENT OF PYRETHROID RESIDUES IN ENVIRONMENTAL AND FOOD SAMPLES BY ENHANCED SOLVENT EXTRACTION/SUPERCRITICAL FLUID EXTRACTION COUPLED WITH GAS CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY

    EPA Science Inventory

    The abstract summarizes pyrethorid methods development research. It provides a summary of sample preparation and analytical techniques such as supercritical fluid extraction, enhance solvent extraction, gas chromatography and tandem mass spectrometry.

  6. Analysis of fifteen estrogen metabolites using packed column supercritical fluid chromatography-mass spectrometry.

    PubMed

    Xu, Xia; Roman, John M; Veenstra, Timothy D; Van Anda, Jennifer; Ziegler, Regina G; Issaq, Haleem J

    2006-03-01

    Packed column supercritical fluid chromatography with tandem mass spectrometry was used for the separation of estrone, estradiol, estriol, 16-epiestriol, 17-epiestriol, 16-ketoestradiol, 16alpha-hydroxyestrone, 2-methoxyestrone, 4-methoxyestrone, 2-hydroxyestrone-3-methyl ether, 2-methoxyestradiol, 4-methoxyestradiol, 2-hydroxyestrone, 4-hydroxyestrone, and 2-hydroxyestradiol. A gradient of methanol in carbon dioxide (0-30% methanol in 15 min, 2% change/min) at a flow rate of 2 mL/min and cyanopropyl silica column connected in series with a diol column, both 2.1 mm i.d. x 150 mm long, packed with 5-mum spherical silica-based particles, resulted in the separation and quantification of all 15 estrogens in less than 10 min. The limit of detection (LOD) and limit of quantitation (LOQ) of this pSFC MS/MS method was determined to be 0.5 (S/N = 3), and 5 pg, respectively. Compared with RP-HPLC MS analysis of the same mixture in terms of speed of analysis and sensitivity, pSFC MS is much faster, 10 versus 70 min, with comparable LOD and LOQ. PMID:16503607

  7. Enantioselective simultaneous analysis of selected pharmaceuticals in environmental samples by ultrahigh performance supercritical fluid based chromatography tandem mass spectrometry.

    PubMed

    Camacho-Muñoz, Dolores; Kasprzyk-Hordern, Barbara; Thomas, Kevin V

    2016-08-31

    In order to assess the true impact of each single enantiomer of pharmacologically active compounds (PACs) in the environment, highly efficient, fast and sensitive analytical methods are needed. For the first time this paper focuses on the use of ultrahigh performance supercritical fluid based chromatography coupled to a triple quadrupole mass spectrometer to develop multi-residue enantioselective methods for chiral PACs in environmental matrices. This technique exploits the advantages of supercritical fluid chromatography, ultrahigh performance liquid chromatography and mass spectrometry. Two coated modified 2.5 μm-polysaccharide-based chiral stationary phases were investigated: an amylose tris-3,5-dimethylphenylcarbamate column and a cellulose tris-3-chloro-4-methylphenylcarbamate column. The effect of different chromatographic variables on chiral recognition is highlighted. This novel approach resulted in the baseline resolution of 13 enantiomers PACs (aminorex, carprofen, chloramphenicol, 3-N-dechloroethylifosfamide, flurbiprofen, 2-hydroxyibuprofen, ifosfamide, imazalil, naproxen, ofloxacin, omeprazole, praziquantel and tetramisole) and partial resolution of 2 enantiomers PACs (ibuprofen and indoprofen) under fast-gradient conditions (<10 min analysis time). The overall performance of the methods was satisfactory. The applicability of the methods was tested on influent and effluent wastewater samples. To the best of our knowledge, this is the first feasibility study on the simultaneous separation of chemically diverse chiral PACs in environmental matrices using ultrahigh performance supercritical fluid based chromatography coupled with tandem mass spectrometry. PMID:27506366

  8. Development and evaluation of supercritical fluid chromatography/mass spectrometry for polar and high-molecular-weight coal components: Technical progress report, October 1, 1986-September 30, 1987

    SciTech Connect

    Chess, E.K.; Kalinoski, H.T.; Smith, R.D.

    1988-02-01

    This program, Development and Evaluation of Supercritical Fluid Chromatography/Mass Spectrometry for Polar and High-Molecular-Weight Coal Components, is aimed at the development of new analytical technologies for the characterization of previously intractable complex mixtures. The specific goals of this program are twofold: (1) to develop and evaluate a combined high-resolution, capillary column, supercritical fluid chromatograph/high-performance mass spectrometer (SFC/MS) that is capable of analyzing high-molecular-weight materials, such as polar and heavy-end components found in coal conversion processes; and (2) to use this system to develop and evaluate analytical technology applicable to coal process development technology. Studies have been conducted to characterize the performance of the supercritical fluid chromatograph-mass spectrometer interface, and several modifications have been made to the probe, ion source, and associated hardware to improve performance and operator safety. Methods have been developed that allow the mass calibration of the magnetic sector mass spectrometer to 1400 daltons using desorption chemical ionization. Methodologies have been improved for fabricating capillary columns with bonded, crosslinked stationary phases suitable for use with polar fluids. Coal-derived materials and fossil-fuel-derived sediments have been investigated with supercritical fluid chromatograph/mass spectrometry and supercritical fluid extraction/mass spectrometry. Microbore packed columns coupled to a modified mass spectrometer interface allowed the chemical class fractionation of relatively polar complex mixtures derived from coal liquefaction. 6 refs., 12 figs.

  9. High-Throughput Analysis of Sucrose Fatty Acid Esters by Supercritical Fluid Chromatography/Tandem Mass Spectrometry

    PubMed Central

    Hori, Katsuhito; Tsumura, Kazunobu; Fukusaki, Eiichiro; Bamba, Takeshi

    2014-01-01

    Supercritical fluid chromatography (SFC) coupled with triple quadrupole mass spectrometry was applied to the profiling of sucrose fatty acid esters (SEs). The SFC conditions (column and modifier gradient) were optimized for the effective separation of SEs. In the column test, a silica gel reversed-phase column was selected. Then, the method was used for the detailed characterization of commercial SEs and the successful analysis of SEs containing different fatty acids. The present method allowed for fast and high-resolution separation of monoesters to tetra-esters within a shorter time (15 min) as compared to the conventional high-performance liquid chromatography. The applicability of our method for the analysis of SEs was thus demonstrated. PMID:26819875

  10. Supercritical fluid extraction of isoflavones from biological samples with ultra-fast high-performance liquid chromatography/mass spectrometry.

    PubMed

    Klejdus, Borivoj; Lojková, Lea; Lapcík, Oldrich; Koblovská, Radka; Moravcová, Jitka; Kubán, Vlastimil

    2005-08-01

    An efficient method of modifier addition for supercritical fluid extraction (SFE) of polar isoflavones was developed and yielded extraordinarily high recoveries. To find the optimal extraction conditions, a temperature and pressure optimization and modifier impact study was performed in naturally contaminated and spiked samples. Ultra-fast high-performance liquid chromatography/mass spectrometry (HPLC/MS) was used for the determination of isoflavones on an Atlantis dC18 high-speed reversed phase chromatographic column (20 x 2.1 mm, 3 microm particle size). A newly elaborated supercritical fluid extraction (SFE) procedure allowed more accurate (< 5%) and precise (< 4-7%) determination of isoflavones in biological materials. The HPLC/MS method significantly reduced analysis time with simultaneous improvement of sensitivity and detection limits. The on-column limits of detection LOD (S/N = 3) for isoflavone glycosides (daidzin, genistin, glycitin, ononin, and sissotrin) were 1.3-3.6 fmol and 0.2-1.0 fmol for aglycones (daidzein, glycitein, genistein, formononetin, and biochanin A), respectively. PMID:16138685

  11. Supercritical fluid chromatography coupled with in-source atmospheric pressure ionization hydrogen/deuterium exchange mass spectrometry for compound speciation.

    PubMed

    Cho, Yunju; Choi, Man-Ho; Kim, Byungjoo; Kim, Sunghwan

    2016-04-29

    An experimental setup for the speciation of compounds by hydrogen/deuterium exchange (HDX) with atmospheric pressure ionization while performing chromatographic separation is presented. The proposed experimental setup combines the high performance supercritical fluid chromatography (SFC) system that can be readily used as an inlet for mass spectrometry (MS) and atmospheric pressure photo ionization (APPI) or atmospheric pressure chemical ionization (APCI) HDX. This combination overcomes the limitation of an approach using conventional liquid chromatography (LC) by minimizing the amount of deuterium solvents used for separation. In the SFC separation, supercritical CO2 was used as a major component of the mobile phase, and methanol was used as a minor co-solvent. By using deuterated methanol (CH3OD), AP HDX was achieved during SFC separation. To prove the concept, thirty one nitrogen- and/or oxygen-containing standard compounds were analyzed by SFC-AP HDX MS. The compounds were successfully speciated from the obtained SFC-MS spectra. The exchange ions were observed with as low as 1% of CH3OD in the mobile phase, and separation could be performed within approximately 20min using approximately 0.24 mL of CH3OD. The results showed that SFC separation and APPI/APCI HDX could be successfully performed using the suggested method. PMID:27020885

  12. Hyphenation of supercritical fluid chromatography and two-dimensional gas chromatography-mass spectrometry for group type separations.

    PubMed

    Potgieter, H; van der Westhuizen, R; Rohwer, E; Malan, D

    2013-06-14

    The Fischer-Tropsch (FT) process produces a variety of compounds over a wide carbon number range and the synthetic crude oil produced by this process is rich in highly valuable olefins and oxygenates, which crude oil only contains at trace levels. The characterization of these products is very challenging even when using comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometry (GC×GC-TOF-MS). The separation between cyclic paraffins and olefins is especially difficult since they elute in similar positions on the GC×GC chromatogram and since they have identical molecular masses with indistinguishable fragmentation patterns. Previously, a high performance liquid chromatography (HPLC) fractionation procedure was used prior to GC×GC-TOF-MS analysis to distinguish between alkenes and alkanes, both cyclic and non-cyclic, however, there was co-elution of the solvents used in the HPLC fractionation procedure, and the volatile components in the gasoline sample and the dilution introduced by the off-line fractionation procedure made it very difficult to investigate components present at very low concentrations. The hyphenation of supercritical fluid chromatography (SFC) to GC×GC is less complicated and the removal of the supercritical CO2 can be easily achieved without any loss of the volatile sample components, eliminating the introduction of co-eluting solvents as well as the dilution effect. This paper describes the on-line hyphenation of SFC to a GC×GC system in order to comprehensively characterize the chemical groups (saturates, unsaturates, oxygenates and aromatics) in an FT sample. PMID:23647609

  13. Mass spectrometry.

    NASA Technical Reports Server (NTRS)

    Burlingame, A. L.; Johanson, G. A.

    1972-01-01

    Review of the current state of mass spectrometry, indicating its unique importance for advanced scientific research. Mass spectrometry applications in computer techniques, gas chromatography, ion cyclotron resonance, molecular fragmentation and ionization, and isotope labeling are covered. Details are given on mass spectrometry applications in bio-organic chemistry and biomedical research. As the subjects of these applications are indicated alkaloids, carbohydrates, lipids, terpenes, quinones, nucleic acid components, peptides, antibiotics, and human and animal metabolisms. Particular attention is given to the mass spectra of organo-inorganic compounds, inorganic mass spectrometry, surface phenomena such as secondary ion and electron emission, and elemental and isotope analysis. Further topics include mass spectrometry in organic geochemistry, applications in geochronology and cosmochemistry, and organic mass spectrometry.

  14. Quantification of tocopherols and tocotrienols in soybean oil by supercritical-fluid chromatography coupled to high-resolution mass spectrometry.

    PubMed

    Méjean, Marie; Brunelle, Alain; Touboul, David

    2015-07-01

    For the most effective analytical strategies, development and validation include optimization of such analytical variables as resolution, detectability, sensitivity, simplicity, cost effectiveness, flexibility, and speed. However, other aspects concerning operator safety and environmental impact are not considered at the same level. The result has been many unintended negative effects of analytical methods developed to investigate different kinds of sample, especially hydrophobic compounds that generate a large amount of chemical waste and have a strong negative environmental impact. In this context, quantification of tocopherols and tocotrienols, i.e. the vitamin E family, is usually achieved by normal-phase liquid chromatography using large volumes of toxic organic solvents, or reversed-phase liquid chromatography using a high percentage of methanol for elution. We propose here a "greener" analytical strategy, including the hyphenation of supercritical-fluid chromatography, using CO2 and ethanol as mobile phase, NH2 as stationary phase, and mass spectrometry for the detection and quantification of vitamin E congeners in soybean oil. An atmospheric-pressure photoionization (APPI) source seemed significantly more sensitive and robust than electrospray or atmospheric-pressure chemical ionization (APCI). This method led to shortened analysis time (less than 5 min) and was revealed to be as sensitive as more traditional approaches, with limits of detection and quantification in the tens of μg L(-1). PMID:25822159

  15. SFC-APLI-(TOF)MS: Hyphenation of Supercritical Fluid Chromatography to Atmospheric Pressure Laser Ionization Mass Spectrometry.

    PubMed

    Klink, Dennis; Schmitz, Oliver Johannes

    2016-01-01

    Atmospheric-pressure laser ionization mass spectrometry (APLI-MS) is a powerful method for the analysis of polycyclic aromatic hydrocarbon (PAH) molecules, which are ionized in a selective and highly sensitive way via resonance-enhanced multiphoton ionization. APLI was presented in 2005 and has been hyphenated successfully to chromatographic separation techniques like high performance liquid chromatography (HPLC) and gas chromatography (GC). In order to expand the portfolio of chromatographic couplings to APLI, a new hyphenation setup of APLI and supercritical-fluid chromatography (SFC) was constructed and aim of this work. Here, we demonstrate the first hyphenation of SFC and APLI in a simple designed way with respect to different optimization steps to ensure a sensitive analysis. The new setup permits qualitative and quantitative determination of native and also more polar PAH molecules. As a result of the altered ambient characteristics within the source enclosure, the quantification of 1-hydroxypyrene (1-HP) in human urine is possible without prior derivatization. The limit of detection for 1-HP by SFC-APLI-TOF(MS) was found to be 0.5 μg L(-1), which is lower than the 1-HP concentrations found in exposed persons. PMID:26633261

  16. Development and evaluation of supercritical fluid chromatography/mass spectrometry for polar and high-molecular-weight coal components. Technical progress report

    SciTech Connect

    Chess, E.K.; Smith, R.D.

    1986-01-01

    This Technical Progress Report reviews the technical progress made over the first 18 months of the program. Our goals include the design, development, and evaluation of a combined capillary column supercritical fluid chromatograph/high-performance mass spectrometer capable of analyzing high-molecular-weight polar materials and evaluating the system's potential for application in coal conversion process monitoring. The program includes not only the development and evaluation of the required instrumentation, but the development of polar fluids and compatible chromatographic stationary phases needed for efficient separation and analysis of polar and high-molecular-weight compounds. A new chromatograph/mass spectrometer interface and new mass spectrometer ion source have been designed, constructed, and evaluated using low-polarity supercritical fluids such as pentane. Results from the evaluations have been used to modify the instrumentation to improve performance. The design and fabrication of capillary flow restrictors from fused silica tubing has been explored. Research has also been conducted toward advancing the technology of fabricating high-performance chromatographic columns suitable for use with polar supercritical fluids. Results to date support our initial belief that high-resolution supercritical fluid chromatography (SFC)/high-performance mass spectrometry (MS) will provide a significantly enhanced analytical capability for broad classes of previously intractable fuel components. 10 refs., 13 figs.

  17. Analysis of polar urinary metabolites for metabolic phenotyping using supercritical fluid chromatography and mass spectrometry.

    PubMed

    Sen, Arundhuti; Knappy, Christopher; Lewis, Matthew R; Plumb, Robert S; Wilson, Ian D; Nicholson, Jeremy K; Smith, Norman W

    2016-06-01

    Supercritical fluid chromatography (SFC) is frequently used for the analysis and separation of non-polar metabolites, but remains relatively underutilised for the study of polar molecules, even those which pose difficulties with established reversed-phase (RP) or hydrophilic interaction liquid chromatographic (HILIC) methodologies. Here, we present a fast SFC-MS method for the analysis of medium and high-polarity (-7≤cLogP≤2) compounds, designed for implementation in a high-throughput metabonomics setting. Sixty polar analytes were first screened to identify those most suitable for inclusion in chromatographic test mixtures; then, a multi-dimensional method development study was conducted to determine the optimal choice of stationary phase, modifier additive and temperature for the separation of such analytes using SFC. The test mixtures were separated on a total of twelve different column chemistries at three different temperatures, using CO2-methanol-based mobile phases containing a variety of polar additives. Chromatographic performance was evaluated with a particular emphasis on peak capacity, overall resolution, peak distribution and repeatability. The results suggest that a new generation of stationary phases, specifically designed for improved robustness in mixed CO2-methanol mobile phases, can improve peak shape, peak capacity and resolution for all classes of polar analytes. A significant enhancement in chromatographic performance was observed for these urinary metabolites on the majority of the stationary phases when polar additives such as ammonium salts (formate, acetate and hydroxide) were included in the organic modifier, and the use of water or alkylamine additives was found to be beneficial for specific subsets of polar analytes. The utility of these findings was confirmed by the separation of a mixture of polar metabolites in human urine using an optimised 7min gradient SFC method, where the use of the recommended column and co

  18. Analysis of basic compounds by supercritical fluid chromatography: attempts to improve peak shape and maintain mass spectrometry compatibility.

    PubMed

    Grand-Guillaume Perrenoud, Alexandre; Boccard, Julien; Veuthey, Jean-Luc; Guillarme, Davy

    2012-11-01

    While neutral and acidic compounds are well separated by supercritical fluid chromatography (SFC), basic analytes are more challenging to separate and often problems occur with their peak shapes. Two different methods were explored in the present paper to reduce these problems and maintain compatibility with mass spectrometry (MS). Five different, commercially available 2-ethylpyridine (2-EP) stationary phases were tested without a mobile phase additive using 92 pharmaceutical compounds with basic properties. The kinetic performances of the 5 columns were nearly identical, but the peak shapes of the basic drugs were strongly affected by the stationary phase. The PrincetonSFC 2-EP and Zymor Pegasus 2-EP phases clearly outperformed the other stationary phases, with 77% and 69% of the compounds having Gaussian peaks (and asymmetries between 0.8 and 1.4), respectively. Comparatively, the Waters Viridis Silica 2-EP, Waters Viridis BEH 2-EP and ES industries GreenSep 2-EP phases provided only 52%, 44% and 22% of the compounds with Gaussian peaks, respectively. These differences were attributed to the significant dissimilarities in their silica matrix properties. An alternative strategy was also performed with a hybrid silica stationary phase, Viridis BEH, using 20mM ammonium hydroxide in the mobile phase, which was a mixture of CO(2) and MeOH. With these conditions, 81% of the peaks observed for the basic analytes were Gaussian; however, this value dropped to 17% and 10% in the absence of additive and in the presence of 20mM formic acid, respectively. Finally, the use of a hybrid bare silica stationary phase in the presence of 20mM ammonium hydroxide is quite an interesting solution as this system is compatible with both ultra high performance SFC (UHPSFC) columns packed with sub-2 μm particles and with MS detection. The overall applicability of this system was demonstrated with various mixtures of basic drugs. PMID:22999421

  19. The coupling of supercritical fluid chromatography and field ionization time-of-flight high-resolution mass spectrometry for rapid and quantitative analysis of petroleum middle distillates.

    PubMed

    Qian, Kuangnan; Diehl, John W; Dechert, Gary J; DiSanzo, Frank P

    2004-01-01

    We report the first coupling of supercritical fluid chromatography (SFC) with field ionization time-of-flight high-resolution mass spectrometry (FI-ToF HRMS), in parallel with ultraviolet (UV) detection and flame ionization detection (FID), for rapid and quantitative analysis of petroleum middle distillates. SFC separates petroleum middle distillates into saturates and 1- to 3-ring aromatics. FI generates molecular ions for hydrocarbon species eluted from the SFC. The high resolution and exact mass measurements by ToF mass spectrometry provide elemental compositions of the molecules in the petroleum product. The amounts of saturates and aromatic ring types were quantified using the parallel SFC-FID assisted by SFC-UV. With a proper carbon-number calibration, the detailed composition of the petroleum middle distillate was rapidly determined. PMID:15103095

  20. FastTrack to supercritical fluid chromatographic purification: Implementation of a walk-up analytical supercritical fluid chromatography/mass spectrometry screening system in the medicinal chemistry laboratory.

    PubMed

    Aurigemma, Christine; Farrell, William

    2010-09-24

    Medicinal chemists often depend on analytical instrumentation for reaction monitoring and product confirmation at all stages of pharmaceutical discovery and development. To obtain pure compounds for biological assays, the removal of side products and final compounds through purification is often necessary. Prior to purification, chemists often utilize open-access analytical LC/MS instruments because mass confirmation is fast and reliable, and the chromatographic separation of most sample constituents is sufficient. Supercritical fluid chromatography (SFC) is often used as an orthogonal technique to HPLC or when isolation of the free base of a compound is desired. In laboratories where SFC is the predominant technique for analysis and purification of compounds, a reasonable approach for quickly determining suitable purification conditions is to screen the sample against different columns. This can be a bottleneck to the purification process. To commission SFC for open-access use, a walk-up analytical SFC/MS screening system was implemented in the medicinal chemistry laboratory. Each sample is automatically screened through six column/method conditions, and on-demand data processing occurs for the chromatographers after each screening method is complete. This paper highlights the "FastTrack" approach to expediting samples through purification. PMID:20728893

  1. Mass spectrometry

    SciTech Connect

    Burlingame, A.L.; Baillie, T.A.; Derrick, P.J.

    1986-04-01

    It is the intention of the review to bring together in one source the direction of major developments in mass spectrometry and to illustrate these by citing key contributions from both fundamental and applied research. The Review is intended to provide the reader with a sense of the main currents, their breadth and depth, and probable future directions. It is also intended to provide the reader with a glimpse of the diverse discoveries and results that underpin the eventual development of new methods and instruments - the keys to obtaining new insights in all the physical, chemical, and biological sciences which depend on mass spectrometry at various levels of sophistication. Focal points for future interdisciplinary synergism might be selective quantitative derivatization of large peptides, which would convey properties that direct fragmentation providing specific sequence information, or optimization of LCMS for biooligomer sequencing and mixture analysis, or the perfect way to control or enhance the internal energy of ions of any size, or many others. 1669 references.

  2. Analysis of glucuronide and sulfate steroids in urine by ultra-high-performance supercritical-fluid chromatography hyphenated tandem mass spectrometry.

    PubMed

    Doué, Mickael; Dervilly-Pinel, Gaud; Pouponneau, Karinne; Monteau, Fabrice; Le Bizec, Bruno

    2015-06-01

    Profiling conjugated urinary steroids to detect anabolic-steroid misuse is recognized as an efficient analytical strategy in both chemical-food-safety and anti-doping fields. The relevance and robustness of such profiling rely on the analysis of glucuronide and sulfate steroids, which is expected to have properties including accuracy, specificity, sensitivity, and, if possible, rapidity. In this context, the ability of ultra-high-performance supercritical-fluid chromatography (UHPSFC) hyphenated tandem mass spectrometry (MS-MS) to provide reliable and accurate phase II analysis of steroids was assessed. Four stationary phases with sub-2 μm particles (BEH, BEH 2-ethyl-pyridine, HSS C18 SB, and CSH fluorophenyl) were screened for their capacity to separate several conjugated steroid isomers. Analytical conditions including stationary phase, modifier composition and percentage, back pressure, column temperature, and composition and flow rate of make-up solvent were investigated to improve the separation and/or the sensitivity. Thus, an analytical procedure enabling the analysis of eight glucuronide and 12 sulfate steroids by two different methods in 12 and 15 min, respectively, was optimized. The two procedures were evaluated, and UHPSFC-MS-MS analysis revealed its ability to provide sensitive (limits of quantification: 0.1 ng mL(-1) and 0.5 ng mL(-1) for sulfate and glucuronide steroids, respectively) and reliable quantitative performance (R(2) > 0.995, RSD < 20%, and bias < 30%) through the use of suitable labeled internal standards. Comparison with UHPLC-MS-MS was performed, and UHPSFC-MS-MS obtained better performance in terms of sensitivity. Finally, as a proof of concept, this so-called green technology was used in a chemical-food-safety context to profile steroid conjugates in urine samples from bovines treated with estradiol. Graphical Abstract Glucuronide and sulfate steroids analysis in urine by ultra-high performance supercritical fluid

  3. Rapid characterization of commercial polysorbate 80 by ultra-high performance supercritical fluid chromatography combined with quadrupole time-of-flight mass spectrometry.

    PubMed

    Pan, Jinheng; Ji, Yu; Du, Zhenxia; Zhang, Jianwen

    2016-09-23

    Polysorbate 80, as a nonionic surfactant, is widely used in the food, personal care, and pharmaceutical industries due to the advantages of high surface activity, low toxicity, etc. In fact, the products of polysorbate 80 are complex mixtures of oligomers. In this work, a novel and fast method was developed to characterize the commercial polysorbate 80 by ultra-high performance supercritical fluid chromatography (UHPSFC) combined with quadrupole time-of-flight mass spectrometry (QTOF-MS). Some crucial parameters, such as temperature, back pressure and flow rate were optimized. UHPSFC could distinguish n-mer from (n-1)-mer and (n+1)-mer in the same series, which provided the high separation resolution needed for quantitative determination of each oligomer in same series. It was not achieved in previous studies. Furthermore, the characteristic ion fragments were found in MS/MS experiment and used to identify different series. The results revealed that main components of this nonionic surfactant comprise polyethylene oxide (PEO), PEO-monooleate, PEO-isosorbide, PEO-isosorbide monooleate, PEO-isosorbide dioleate, PEO-sorbitan, PEO-sorbitan monooleate, PEO-sorbitan dioleate and PEO-sorbitan trioleate, etc. The separation was performed using BEH stationary phase, so the relationship between molecular structure of these oligomers and chromatographic retention behavior in supercritical fluid chromatography were also investigated for first time. The whole analytical process only takes 8min for one sample. Therefore, UHPSFC-QTOF-MS is a simple, novel and efficient tool to analyze polysorbate 80. PMID:27578407

  4. A fast and sensitive method for the separation of carotenoids using ultra-high performance supercritical fluid chromatography-mass spectrometry.

    PubMed

    Jumaah, Firas; Plaza, Merichel; Abrahamsson, Victor; Turner, Charlotta; Sandahl, Margareta

    2016-08-01

    In this study, a rapid and sensitive ultra-high performance supercritical fluid chromatography-mass spectrometry (UHPSFC-MS) method has been developed and partially validated for the separation of carotenoids within less than 6 min. Six columns of orthogonal selectivity were examined, and the best separation was obtained by using a 1-aminoanthracene (1-AA) column. The length of polyene chain as well as the number of hydroxyl groups in the structure of the studied carotenoids determines their differences in the physiochemical properties and thus the separation that is achieved on this column. All of the investigated carotenoids were baseline separated with resolution values greater than 1.5. The effects of gradient program, back pressure, and column temperature were studied with respect to chromatographic properties such as retention and selectivity. Electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) were compared in both positive and negative mode, using both direct infusion and hyphenated with UHPSFC. The ESI in positive mode provided the highest response. The coefficient of determination (R (2)) for all calibration curves were greater than 0.998. Limit of detection (LOD) was in the range of 2.6 and 25.2 ng/mL for α-carotene and astaxanthin, respectively, whereas limit of quantification (LOQ) was in the range of 7.8 and 58.0 ng/mL for α-carotene and astaxanthin, respectively. Repeatability and intermediate precision of the developed UHPSFC-MS method were determined and found to be RSD < 3 % and RSD < 6 %, respectively. The method was applied in order to determine carotenoids in supercritical fluid extracts of microalgae and rosehip. Graphical Abstract Ultra-high performance supercritical fluid chromatography-a rapid separation method for the analysis of carotenoids in rosehip and microalgae samples. PMID:27349917

  5. Supercritical fluid chromatography-tandem mass spectrometry for fast bioanalysis of R/S-warfarin in human plasma.

    PubMed

    Coe, Roger A; Rathe, Jonathan O; Lee, Jean W

    2006-11-16

    Chiral separation for the analysis of enantiomers in biological fluids by HPLC often takes relatively long chromatography time compared to achiral analysis. The advantage of fast mass transfer in packed-column supercritical fluid chromatography (pSFC) and the high-flow compatibility of APCI-MS/MS were applied to develop a fast bioanalytical method for R/S-warfarin in human plasma. Presented here are the main challenges encountered during method development of a semi-automated liquid extraction SFC-MS/MS method. The selection of internal standard, robustness of the SFC equipment, and carryover issues are discussed. The method has high-throughput: the chromatography time is at least two-fold faster than the our fastest previous method; and the liquid/liquid extraction time of 96 samples is less than 20 min using a Tecan Genesis RSP 100 pipetting station and a Tomtec Quadra-96 workstation. The standard curve range was 13.6-2500 ng/ml. Precision of QC concentrations from four validation runs was 7.0% for R-warfarin and 6.0% C.V. for S-warfarin; and the bias was 3.7 and 3.2% R.E., respectively. The method is sensitive, accurate, selective and robust, and was applied to a drug-interaction clinical study with rapid turnaround of sample analysis. PMID:16875793

  6. Rapid chiral separation of atenolol, metoprolol, propranolol and the zwitterionic metoprolol acid using supercritical fluid chromatography-tandem mass spectrometry - Application to wetland microcosms.

    PubMed

    Svan, Alfred; Hedeland, Mikael; Arvidsson, Torbjörn; Jasper, Justin T; Sedlak, David L; Pettersson, Curt E

    2015-08-28

    A method for enantiomeric separation of the three β-blocking agents atenolol, metoprolol, propranolol and the zwitterionic metoprolol acid, a major metabolite of both metoprolol and in environmental matrices also atenolol, has been developed. By use of supercritical fluid chromatography and the polysaccharide-based Chiralpak(®) IB-3, all four compounds were simultaneously enantiomerically separated (Rs>1.5) within 8min. Detection was performed using tandem mass spectrometry, and to avoid isobaric interference between the co-eluting metoprolol and metoprolol acid, the achiral column Acquity(®) UPC(2) BEH 2-EP was attached ahead of to the chiral column. Carbon dioxide with 18% methanol containing 0.5% (v/v) of the additives trifluoroacetic acid and ammonia in a 2:1 molar ratio were used as mobile phase. A post column make-up flow (0.3mL/min) of methanol containing 0.1% (v/v) formic acid was used to enhance the positive electrospray ionization. Detection was carried out using a triple quadrupole mass spectrometer operating in the selected reaction monitoring mode, using one transition per analyte and internal standard. The method was successfully applied for monitoring the enantiomeric fraction change over time in a laboratory scale wetland degradation study. It showed good precision, recovery, sensitivity and low effect of the sample matrix. PMID:26228849

  7. Quantification of the neurotransmitters melatonin and N-acetyl-serotonin in human serum by supercritical fluid chromatography coupled with tandem mass spectrometry.

    PubMed

    Wolrab, Denise; Frühauf, Peter; Gerner, Christopher

    2016-09-21

    The aim of this study was developing a supercritical fluid chromatography tandem mass spectrometry (SFC-MS/MS) method and an ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method, for the analysis of N-acetyl-serotonin (NAS) and melatonin (Mel) in human serum, and to compare the performance of these methods. Deuterated isotopologues of the neurotransmitters were synthesized and evaluated for suitability as internal standards in sample preparation. Liquid-liquid extraction was selected as sample preparation procedure. With chloroform, the best extraction solvent tested, an extraction yield of 48 ± 2% for N-acetyl-serotonin and 101 ± 10% for melatonin was achieved. SFC separation was accomplished within 3 min on a BEH stationary phase, employing isocratic elution with 90% carbon dioxide and 0.1% formic acid as well as 0.05% ammonium formate in methanol. For the 4 min UHPLC gradient separation with 0.1% formic acid in water and methanol, respectively, a Kinetex XB-C18 was used as stationary phase. Both chromatographic techniques were optimized regarding mobile phase composition, additives to the mobile phase and column temperature. Multiple reaction monitoring (MRM) analysis was used for quantification of the metabolites. Both methods were validated regarding retention time stability, LOD, LOQ, repeatability and reproducibility of quantification, process efficiency, extraction recovery and matrix effects. LOD and LOQ were 0.017 and 0.05 pg μL(-1) for NAS and 0.006 and 0.018 pg μL(-1) for Mel in SFC-MS/MS compared to 0.028 and 0.1 pg μL(-1) for NAS and 0.006 and 0.017 pg μL(-1) for Mel in UHPLC-MS/MS. PMID:27590559

  8. Simultaneous determination of 17 disperse dyes in textile by ultra-high performance supercritical fluid chromatography combined with tandem mass spectrometry.

    PubMed

    Zhou, Ying; Du, Zhenxia; Zhang, Yun

    2014-09-01

    A simple, highly sensitive and fast procedure for the control of 17 allergenic and prohibited disperse dyes in textile products was optimized. The method was based on ultrasound assisted extraction of textile samples with 10 mL of methanol under controlled conditions (30 min, 70°C). The extracts were analyzed by the ultra-high performance supercritical fluid chromatography (UHPSFC) system coupled with triple quadrupole tandem mass spectrometry (MS/MS). Four stationary phases (BEH, BEH 2-ethyl-pyridine, HSS C18 SB and CSH fluorophenyl) were screened as well as analytical conditions (modifier percentage, backpressure and column temperature) were investigated to improve the separation. All 17 disperse dyes were simultaneously separated and determined by UHPSFC-MS/MS in 5 min. The dyes were monitored via the ESI(+) ionization method and quantified by 3-channel multiple reaction monitoring (MRM). The calibrations were performed and good linear relationship (R≥0.99) was observed within the concentration range of 2-50 μg mL(-1). Satisfactory recoveries (70.55-103.03%) of all the disperse dyes spiked with standards at different levels were demonstrated. This is the first report on the simultaneous analysis of disperse dyes using UHPSFC-MS/MS. PMID:24913864

  9. Stereoselective analysis of novel chiral fungicide pyrisoxazole in cucumber, tomato and soil under different application methods with supercritical fluid chromatography/tandem mass spectrometry.

    PubMed

    Pan, Xinglu; Dong, Fengshou; Xu, Jun; Liu, Xingang; Chen, Zenglong; Zheng, Yongquan

    2016-07-01

    Various new chiral pesticides have been registered and used in crop yields. However, few studies have focused on the environmental behavior of such new registered chiral compounds on the stereoisomer level. In this study, an effective and sensitive chiral analytical method was first developed to detect pyrisoxazole stereoisomers and then further applied to investigate the stereoselective dissipation in vegetables and soil using supercritical fluid chromatography/tandem triple quadrupole mass spectrometry. Optimal separation condition was achieved with IA column using CO2/MeOH (75:25) as mobile phase at 2.0 mL/min in 5 min, 35 °C and 2400 psi. The average recoveries in all of the matrices at four spiking levels ranged from 84.0% to 105.6%. Significant stereoselective dissipation was observed in cucumber and tomato under both application modes. (-) Pyrisoxazole A and (-) pyrisoxazole B were preferentially degraded in cucumber under foliar spraying mode. In contrast, (+) pyrisoxazole A and (-) pyrisoxazole B were preferentially degraded in cucumber under soil irrigation mode. (-) Pyrisoxazole A and (-) pyrisoxazole B were degraded faster than their antipodes in tomato under both application modes. However, no significant stereoselectivity was observed in soil. The results of this study could help facilitate more accurate risk assessments of pyrisoxazole. PMID:26970041

  10. Characterization via liquid chromatography coupled to diode array detector and tandem mass spectrometry of supercritical fluid antioxidant extracts of Spirulina platensis microalga.

    PubMed

    Mendiola, Jose A; Marín, Francisco R; Hernández, S Francisco; Arredondo, Bertha O; Señoráns, F Javier; Ibañez, Elena; Reglero, Guillermo

    2005-06-01

    Spirulina platensis microalga has been extracted on a pilot scale plant using supercritical fluid extraction (SFE) under various extraction conditions. The extraction yield and the antioxidant activity of the extracts were evaluated in order to select those extracts with both the highest antioxidant capacity and a good extraction yield. These extracts were characterized using LC coupled to diode array detection (DAD) and LC coupled to mass spectrometry (MS) with two different interfaces, atmospheric pressure chemical ionization (APCI) and electrospray (ESI) which allowed us to perform tandem MS by using an ion trap analyzer. The best extraction conditions were as follows: CO2 with 10% of modifier (ethanol) as extraction solvent, 55 degrees C (extraction temperature) and 220 bar (extraction pressure). Fractionation was achieved by cascade depressurization providing two extracts with different activity and chemical composition. Several compounds have been identified in the extracts, corresponding to different carotenoids previously identified in Spirulina platensis microalga along with chlorophyll a and some degradation products. Also, the structure of some phenolic compounds could be tentatively identified. The antioxidant activity of the extracts could be attributed to some of the above mentioned compounds. PMID:16013830

  11. MASS SPECTROMETRY

    DOEpatents

    Nier, A.O.C.

    1959-08-25

    A voltage switching apparatus is described for use with a mass spectrometer in the concentratron analysis of several components of a gas mixture. The system automatically varies the voltage on the accelerating electrode of the mass spectrometer through a program of voltages which corresponds to the particular gas components under analysis. Automatic operation may be discontinued at any time to permit the operator to manually select any desired predetermined accelerating voltage. Further, the system may be manually adjusted to vary the accelerating voltage over a wide range.

  12. Ultra-high performance supercritical fluid chromatography coupled with quadrupole-time-of-flight mass spectrometry as a performing tool for bioactive analysis.

    PubMed

    Grand-Guillaume Perrenoud, Alexandre; Guillarme, Davy; Boccard, Julien; Veuthey, Jean-Luc; Barron, Denis; Moco, Sofia

    2016-06-10

    Secondary metabolites are an almost unlimited reservoir of potential bioactive compounds. In view of the wide chemical space covered by natural compounds, their comprehensive analysis requires multiple cutting-edge approaches. This study evaluates the applicability of ultra-high performance supercritical fluid chromatography coupled to quadrupole-time-of-flight mass spectrometry (UHPSFC-QqToF-MS) as an analytical strategy for plant metabolites profiling. Versatility of this analytical platform was first assessed using 120 highly diverse natural compounds (according to lipophilicity, hydrogen bond capability, acid-base properties, molecular mass and chemical structure) that were screened on a set of 15 rationally chosen stationary phase chemistries. UHPSFC-QqToF-MS provides a suitable analytical solution for 88% of the tested compounds. Three stationary phases (Diol, not endcapped C18 and 2-EP) were highlighted as particularly polyvalent, since they allow suitable elution of 101 out of 120 natural compounds. The systematic evaluation of retention and selectivity of natural compounds further underlined the suitability of these three columns for the separation of natural compounds. This reduced set of key stationary phases constitutes a basis for untargeted scouting analysis and method development. Even if they were less versatile, stationary phases such as endcapped T3C18, polar P-PFP, were nevertheless found to provide extended selectivity for specific natural molecules sub-classes. Finally, the identified polyvalent conditions were successfully applied for the analysis of complex polar and non-polar plant extracts. These first experimental hits demonstrate the full applicability and potential of UHPSFC-QqToF-MS for plant metabolite profiling. PMID:27156735

  13. MASS SPECTROMETRY

    DOEpatents

    Friedman, L.

    1962-01-01

    method is described for operating a mass spectrometer to improve its resolution qualities and to extend its period of use substantially between cleanings. In this method, a small amount of a beta emitting gas such as hydrogen titride or carbon-14 methane is added to the sample being supplied to the spectrometer for investigation. The additive establishes leakage paths on the surface of the non-conducting film accumulating within the vacuum chamber of the spectrometer, thereby reducing the effect of an accumulated static charge on the electrostatic and magnetic fields established within the instrument. (AEC)

  14. Fast and sensitive supercritical fluid chromatography - tandem mass spectrometry multi-class screening method for the determination of doping agents in urine.

    PubMed

    Nováková, Lucie; Desfontaine, Vincent; Ponzetto, Federico; Nicoli, Raul; Saugy, Martial; Veuthey, Jean-Luc; Guillarme, Davy

    2016-04-01

    This study shows the possibility offered by modern ultra-high performance supercritical fluid chromatography combined with tandem mass spectrometry in doping control analysis. A high throughput screening method was developed for 100 substances belonging to the challenging classes of anabolic agents, hormones and metabolic modulators, synthetic cannabinoids and glucocorticoids, which should be detected at low concentrations in urine. To selectively extract these doping agents from urine, a supported liquid extraction procedure was implemented in a 48-well plate format. At the tested concentration levels ranging from 0.5 to 5 ng/mL, the recoveries were better than 70% for 48-68% of the compounds and higher than 50% for 83-87% of the tested substances. Due to the numerous interferences related to isomers of steroids and ions produced by the loss of water in the electrospray source, the choice of SFC separation conditions was very challenging. After careful optimization, a Diol stationary phase was employed. The total analysis time for the screening assay was only 8 min, and interferences as well as susceptibility to matrix effect (ME) were minimized. With the developed method, about 70% of the compounds had relative ME within the range ±20%, at a concentration of 1 and 5 ng/mL. Finally, limits of detection achieved with the above-described strategy including 5-fold preconcentration were below 0.1 ng/mL for the majority of the tested compounds. Therefore, LODs were systematically better than the minimum required performance levels established by the World anti-doping agency, except for very few metabolites. PMID:26995645

  15. Response surface methodology for the enantioseparation of dinotefuran and its chiral metabolite in bee products and environmental samples by supercritical fluid chromatography/tandem mass spectrometry.

    PubMed

    Chen, Zenglong; Dong, Fengshou; Li, Shasha; Zheng, Zuntao; Xu, Yongwei; Xu, Jun; Liu, Xingang; Zheng, Yongquan

    2015-09-01

    Tracing the enantiomers of dinotefuran and its metabolite in bee products and relevant environmental matrices is vital because of the high toxicity of their racemates to bees. In this study, a statistical optimization strategy using three-dimensional response surface methodology for the enantioseparation of dinotefuran and its metabolite UF was developed by a novel supercritical fluid chromatography/tandem mass spectrometry (SFC-MS/MS) technique. After direct evaluation of the chromatographic variables - co-solvent content, mobile phase flow rate, automated backpressure regulator pressure (ABPR), and column temperature - involved in the separation mechanism and assessment of the interactions among these variables, the optimal SFC-MS/MS working conditions were selected as a CO2/2% formic acid-methanol mobile phase, 1.9mL/min flow rate, 2009.8psi ABPR, and 26.0°C column temperature using an amylose tris-(3,5-dimethylphenylcarbamate) chiral stationary phase under electrospray ionization positive mode. Baseline resolution, favorable retention, and high sensitivity of the two pairs of enantiomers were achieved in pollen, honey, water, and soil matrices within 4.5min. Additionally, the parameters affecting the dispersive solid-phase extraction procedure, such as the type and content of extractant or purification sorbents, were systematically screened to obtain better extraction yields of the enantiomers. Mean recoveries were between 78.3% and 100.2% with relative standard deviations lower than 8.0% in all matrices. The limits of quantification ranged from 1.0μg/kg to 12.5μg/kg for the dinotefuran and UF enantiomers. Furthermore, the developed method was effectively applied to authentic samples from a market, an irrigation canal, and a trial field, and the enantioselective dissipation of dinotefuran and UF in soil was demonstrated. PMID:26243706

  16. A rapid method for the separation of vitamin D and its metabolites by ultra-high performance supercritical fluid chromatography-mass spectrometry.

    PubMed

    Jumaah, Firas; Larsson, Sara; Essén, Sofia; Cunico, Larissa P; Holm, Cecilia; Turner, Charlotta; Sandahl, Margareta

    2016-04-01

    In this study, a new supercritical fluid chromatography-mass spectrometry (SFC-MS) method has been developed for the separation of nine vitamin D metabolites within less than eight minutes. This is the first study of analysis of vitamin D and its metabolites carried out by SFC-MS. Six columns of orthogonal selectivity were examined, and the best separation was obtained by using a 1-aminoanthracene (1-AA) column. The number and the position of hydroxyl groups in the structure of the studied compounds as well as the number of unsaturated bonds determine the physiochemical properties and, thus the separation of vitamin D metabolites that is achieved on this column. All D2 and the D3 forms were baseline separated with resolution values>1.5. The effects of pressure, temperature, flow rate and different gradient modes were studied. Electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) were compared in positive mode, both by direct infusion and after SFC separation. The results showed that the sensitivity in APCI(+) was higher than in ESI(+) using direct infusion. In contrast, the sensitivity in APCI(+) was 6-fold lower than in ESI(+) after SFC separation. The SFC-MS method was validated between 10 and 500ng/mL for all analytes with coefficient of determination (R(2))≥0.999 for all calibration curves. The limits of detection (LOD) were found to range between 0.39 and 5.98ng/mL for 24,25-dihydroxyvitamin D3 (24,25(OH)2D3) and 1-hydroxyvitamin D2 (1OHD2), respectively. To show its potential, the method was applied to human plasma samples from healthy individuals. Vitamin D3 (D3), 25-hydroxyvitamin D3 (25OHD3) and 24,25(OH)2D3 were determined in plasma samples and the concentrations were 6.6±3.0ng/mL, 23.8±9.2ng/mL and 5.4±2.7ng/mL, respectively. PMID:26931428

  17. Fourier Transform Mass Spectrometry

    PubMed Central

    Scigelova, Michaela; Hornshaw, Martin; Giannakopulos, Anastassios; Makarov, Alexander

    2011-01-01

    This article provides an introduction to Fourier transform-based mass spectrometry. The key performance characteristics of Fourier transform-based mass spectrometry, mass accuracy and resolution, are presented in the view of how they impact the interpretation of measurements in proteomic applications. The theory and principles of operation of two types of mass analyzer, Fourier transform ion cyclotron resonance and Orbitrap, are described. Major benefits as well as limitations of Fourier transform-based mass spectrometry technology are discussed in the context of practical sample analysis, and illustrated with examples included as figures in this text and in the accompanying slide set. Comparisons highlighting the performance differences between the two mass analyzers are made where deemed useful in assisting the user with choosing the most appropriate technology for an application. Recent developments of these high-performing mass spectrometers are mentioned to provide a future outlook. PMID:21742802

  18. Fourier Transform Mass Spectrometry.

    ERIC Educational Resources Information Center

    Gross, Michael L.; Rempel, Don L.

    1984-01-01

    Discusses the nature of Fourier transform mass spectrometry and its unique combination of high mass resolution, high upper mass limit, and multichannel advantage. Examines its operation, capabilities and limitations, applications (ion storage, ion manipulation, ion chemistry), and future applications and developments. (JN)

  19. Mass Spectrometry for the Masses

    ERIC Educational Resources Information Center

    Persinger, Jared D.; Hoops, Geoffrey, C.; Samide, Michael J.

    2004-01-01

    A simple, qualitative experiment is developed for implementation, where the gas chromatography-mass spectrometry (GC-MS) plays an important role, into the laboratory curriculum of a chemistry course designed for nonscience majors. This laboratory experiment is well suited for the students as it helps them to determine the validity of their…

  20. Detection of related substances in polyene phosphatidyl choline extracted from soybean and in its commercial capsule by comprehensive supercritical fluid chromatography with mass spectrometry compared with HPLC with evaporative light scattering detection.

    PubMed

    Jiang, Qikun; Liu, Wanjun; Li, Xiaoting; Zhang, Tianhong; Wang, Yongjun; Liu, Xiaohong

    2016-01-01

    Supercritical fluid chromatography with tandem mass spectrometry was used to comprehensively profile polyene phosphatidyl choline (PPC) extracted from soybean. We achieved an efficient chromatographic analysis using a BEH-2EP column (3 × 100 mm(2) , 1.7 μm) with a mobile phase consisting of CO2 and a cosolvent in gradient combination at a flow rate of 1.0 mL/min. The cosolvent consisted of methanol, acetonitrile, and water (containing 10 mM ammonium acetate and 0.2% formic acid). The total single-run time was 7 min. We used this method to accurately detect ten different phospholipids (PLs) during extraction. The limits of quantification for phosphatidyl choline, lyso-phosphatidylcholine (LPC), phosphatidic acid (PA), sphingomyelin, phosphatidyl glycerol, phosphatidyl inositol (PI), cholesterol, cardiolipin, phosphatidyl serine, and phosphatidyl ethanolamine (PE) were 20.6, 19.52, 1.21, 2.38, 0.50, 2.28, 54.3, 0.60, 0.65, and 4.85 ng/mL, respectively. However, adopting the high-performance liquid chromatography with evaporative light scattering detection method issued by the China Food and Drug Administration, only PA, LPC, PE, PI, and PPC could be analyzed accurately, and the limits of quantification were 33.89, 60.5, 30.3, 10.9, and 61.79 μg/mL, respectively. The total single-run time was at the least 20 min. Consequently, the supercritical fluid chromatography with tandem mass spectrometry method was more suitable for the analysis of related PLs. PMID:26614404

  1. Development and evaluation of supercritical fluid chromatography/mass spectrometry for polar and high-molecular-weight coal components: Technical progress report for the period October 1, 1985 - September 30, 1986

    SciTech Connect

    Chess, E.K.; Kalinoski, H.T.; Wright, B.W.; Smith, R.D.

    1987-02-01

    Technical progress toward the programmatic goals of developing and evaluating SFC/MS for the analysis of higher-molecular-weight compounds was made in the following areas: Studies have been conducted to characterize the requirements for and to facilitate the transfer of thermal energy to the capillary flow restrictor region. Such studies have resulted in a new interface probe design which allows better transport of higher molecular weight, less volatile compounds decreasing the mass discrimination at the supercritical fluid chromatograph mass spectrometer interface region. Calibration of the magnetic sector mass spectrometer to 1400 daltons has been developed. A digital syringe pump controller, interfaced to an Apple IIe computer allows much finer and more reproducible control of the pressure (density) of the supercritical fluid mobile phase. Nonpolar supercritical fluid mobile phases have been modified by the addition of small amounts of polar fluids to create fluids with higher solvating powers than, but with similar operating parameters. An in-depth knowledge of the fluid behavior is required for successful utilization of these modified fluids. Polar-modified fluids have been used with three types of supercritical fluid introduction to the mass spectrometer: direct fluid injection, supercritical fluid chromatography, and supercritical fluid extraction. Capillary columns evaluated for stability indicated that our present methods for preparing columns are sufficient, for many of the stationary phase and supercritical fluid combinations tested, to create columns that can be used successfully with supercritical fluid chromatography. 9 refs., 11 figs.

  2. Forensic Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Hoffmann, William D.; Jackson, Glen P.

    2015-07-01

    Developments in forensic mass spectrometry tend to follow, rather than lead, the developments in other disciplines. Examples of techniques having forensic potential born independently of forensic applications include ambient ionization, imaging mass spectrometry, isotope ratio mass spectrometry, portable mass spectrometers, and hyphenated chromatography-mass spectrometry instruments, to name a few. Forensic science has the potential to benefit enormously from developments that are funded by other means, if only the infrastructure and personnel existed to adopt, validate, and implement the new technologies into casework. Perhaps one unique area in which forensic science is at the cutting edge is in the area of chemometrics and the determination of likelihood ratios for the evaluation of the weight of evidence. Such statistical techniques have been developed most extensively for ignitable-liquid residue analyses and isotope ratio analysis. This review attempts to capture the trends, motivating forces, and likely impact of developing areas of forensic mass spectrometry, with the caveat that none of this research is likely to have any real impact in the forensic community unless: (a) The instruments developed are turned into robust black boxes with red and green lights for positives and negatives, respectively, or (b) there are PhD graduates in the workforce who can help adopt these sophisticated techniques.

  3. Forensic Mass Spectrometry.

    PubMed

    Hoffmann, William D; Jackson, Glen P

    2015-01-01

    Developments in forensic mass spectrometry tend to follow, rather than lead, the developments in other disciplines. Examples of techniques having forensic potential born independently of forensic applications include ambient ionization, imaging mass spectrometry, isotope ratio mass spectrometry, portable mass spectrometers, and hyphenated chromatography-mass spectrometry instruments, to name a few. Forensic science has the potential to benefit enormously from developments that are funded by other means, if only the infrastructure and personnel existed to adopt, validate, and implement the new technologies into casework. Perhaps one unique area in which forensic science is at the cutting edge is in the area of chemometrics and the determination of likelihood ratios for the evaluation of the weight of evidence. Such statistical techniques have been developed most extensively for ignitable-liquid residue analyses and isotope ratio analysis. This review attempts to capture the trends, motivating forces, and likely impact of developing areas of forensic mass spectrometry, with the caveat that none of this research is likely to have any real impact in the forensic community unless: (a) The instruments developed are turned into robust black boxes with red and green lights for positives and negatives, respectively, or (b) there are PhD graduates in the workforce who can help adopt these sophisticated techniques. PMID:26070716

  4. Ambient ionization mass spectrometry

    NASA Astrophysics Data System (ADS)

    Lebedev, A. T.

    2015-07-01

    Ambient ionization mass spectrometry emerged as a new scientific discipline only about ten years ago. A considerable body of information has been reported since that time. Keeping the sensitivity, performance and informativity of classical mass spectrometry methods, the new approach made it possible to eliminate laborious sample preparation procedures and triggered the development of miniaturized instruments to work directly in the field. The review concerns the theoretical foundations and design of ambient ionization methods. Their advantages and drawbacks, as well as prospects for application in chemistry, biology, medicine, environmetal analysis, etc., are discussed. The bibliography includes 194 references.

  5. Separation and determination of diversiform phytosterols in food materials using supercritical carbon dioxide extraction and ultraperformance liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry.

    PubMed

    Lu, Baiyi; Zhang, Ying; Wu, Xiaoqin; Shi, Jiayi

    2007-04-01

    This paper presents at first time that the ultra-performance liquid chromatographic atmospheric pressure chemical ionization mass spectrometer (UPLC-APCI-MS) was used as an efficient method for the identification and quantification of diversiform phytosterols in food materials. The sample preparation consisted of extraction by supercritical carbon dioxide fluid extraction (SCE) and saponification by refluxing with ethanolic KOH, and then the non-saponificable fraction was extracted with petroleum ether. This fraction was subjected to solid phase extraction (SPE) on silica gel cartridge and then the sterols were eluted with hexane-ethyl acetate. Sterols were separated on an Acquity UPLC BEH C18 column (100 mm x 1.0 mm, 1.7 microm particle size) with a gradient of methanol/water (1% acetonitrile) at a flow of 0.1 mL min(-1). The determination was performed in selective ion monitoring mode. The quality parameter of the developed method was established using 6-ketocholestanol as internal standard. Limits of quantification (LOQ) were 0.1754, 0.0341, 0.0500, 0.0205, 0.0225, 0.3674, 0.0241, 0.0272, 0.0076 microg L(-1) and 0.1525 microg mL(-1) for 6-ketocholestanol, desmosterol, ergosterol, cholesterol, lanosterol, cholestanol, campesterol, stigmasterol, beta-sitosterol, and stigmastanol, respectively. The intra- and inter-day determination precision for the 10 phytosterols were less than 5 and 6% in relative standard deviations, and their recoveries were located in the range of 94-107%. The developed approach has been applied successfully for efficient determination of diversiform phytosterols in food materials, including corn, sesame, oat and peanut. PMID:17386793

  6. Analytical mass spectrometry

    SciTech Connect

    Not Available

    1990-01-01

    This 43rd Annual Summer Symposium on Analytical Chemistry was held July 24--27, 1990 at Oak Ridge, TN and contained sessions on the following topics: Fundamentals of Analytical Mass Spectrometry (MS), MS in the National Laboratories, Lasers and Fourier Transform Methods, Future of MS, New Ionization and LC/MS Methods, and an extra session. (WET)

  7. Analytical mass spectrometry. Abstracts

    SciTech Connect

    Not Available

    1990-12-31

    This 43rd Annual Summer Symposium on Analytical Chemistry was held July 24--27, 1990 at Oak Ridge, TN and contained sessions on the following topics: Fundamentals of Analytical Mass Spectrometry (MS), MS in the National Laboratories, Lasers and Fourier Transform Methods, Future of MS, New Ionization and LC/MS Methods, and an extra session. (WET)

  8. Ion mobility spectrometry after supercritical fluid chromatography

    SciTech Connect

    Morrissey, M.A.

    1988-01-01

    In this work, a Fourier transform ion mobility spectrometer (FT-IMS) was constructed and evaluated as a detector for supercritical fluid chromatography (SFC). The FT-IMS provides both quantitative and qualitative data of a wide range of compounds, selective and nonselective modes of chromatographic detection, and it is compatible with a wide range of SFC mobile phases. Drift spectra are presented for a number of samples, including polymers, lipids, herbicides, antibiotics, and pharmaceuticals. The unique properties of supercritical fluids made it possible to introduce these compounds into the spectrometer. While the drift spectra presented are generally simple, showing only a quasi-molecular ion, a few are surprising complex. Examples of selective and non-selective detection demonstrate the usefulness of the detector. Examples are presented for fish oil concentrate, bacon grease extract, soil extract, and polymer mixtures. In the case of Triton X-100, a non-ionic surfactant, the FT-IMS was able to selectively detect individual oligomers in the polymer mixture. In the case of a polydimethylsilicone mixture the detector isolated a contaminant in the mixture.

  9. Biological Cluster Mass Spectrometry

    PubMed Central

    Winograd, Nicholas; Garrison, Barbara J.

    2010-01-01

    This article reviews the new physics and new applications of secondary ion mass spectrometry using cluster ion probes. These probes, particularly C60, exhibit enhanced molecular desorption with improved sensitivity owing to the unique nature of the energy-deposition process. In addition, these projectiles are capable of eroding molecular solids while retaining the molecular specificity of mass spectrometry. When the beams are microfocused to a spot on the sample, bioimaging experiments in two and three dimensions are feasible. We describe emerging theoretical models that allow the energy-deposition process to be understood on an atomic and molecular basis. Moreover, experiments on model systems are described that allow protocols for imaging on biological materials to be implemented. Finally, we present recent applications of imaging to biological tissue and single cells to illustrate the future directions of this methodology. PMID:20055679

  10. MASS SPECTROMETRY IN ENVIRONMENTAL SCIENCES

    EPA Science Inventory

    This review covers applications of mass spectrometry to the environmental sciences. From the early applications of mass spectrometry to environmental research in the 1960s and 1970s, mass spectrometry has played an important role in aiding our understanding of environmental poll...

  11. "Magic" Ionization Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Trimpin, Sarah

    2016-01-01

    The systematic study of the temperature and pressure dependence of matrix-assisted ionization (MAI) led us to the discovery of the seemingly impossible, initially explained by some reviewers as either sleight of hand or the misinterpretation by an overzealous young scientist of results reported many years before and having little utility. The "magic" that we were attempting to report was that with matrix assistance, molecules, at least as large as bovine serum albumin (66 kDa), are lifted into the gas phase as multiply charged ions simply by exposure of the matrix:analyte sample to the vacuum of a mass spectrometer. Applied heat, a laser, or voltages are not necessary to achieve charge states and ion abundances only previously observed with electrospray ionization (ESI). The fundamentals of how solid phase volatile or nonvolatile compounds are converted to gas-phase ions without added energy currently involves speculation providing a great opportunity to rethink mechanistic understanding of ionization processes used in mass spectrometry. Improved understanding of the mechanism(s) of these processes and their connection to ESI and matrix-assisted laser desorption/ionization may provide opportunities to further develop new ionization strategies for traditional and yet unforeseen applications of mass spectrometry. This Critical Insights article covers developments leading to the discovery of a seemingly magic ionization process that is simple to use, fast, sensitive, robust, and can be directly applied to surface characterization using portable or high performance mass spectrometers.

  12. "Magic" Ionization Mass Spectrometry.

    PubMed

    Trimpin, Sarah

    2016-01-01

    The systematic study of the temperature and pressure dependence of matrix-assisted ionization (MAI) led us to the discovery of the seemingly impossible, initially explained by some reviewers as either sleight of hand or the misinterpretation by an overzealous young scientist of results reported many years before and having little utility. The “magic” that we were attempting to report was that with matrix assistance, molecules, at least as large as bovine serum albumin (66 kDa), are lifted into the gas phase as multiply charged ions simply by exposure of the matrix:analyte sample to the vacuum of a mass spectrometer. Applied heat, a laser, or voltages are not necessary to achieve charge states and ion abundances only previously observed with electrospray ionization (ESI). The fundamentals of how solid phase volatile or nonvolatile compounds are converted to gas-phase ions without added energy currently involves speculation providing a great opportunity to rethink mechanistic understanding of ionization processes used in mass spectrometry. Improved understanding of the mechanism(s) of these processes and their connection to ESI and matrix-assisted laser desorption/ionization may provide opportunities to further develop new ionization strategies for traditional and yet unforeseen applications of mass spectrometry. This Critical Insights article covers developments leading to the discovery of a seemingly magic ionization process that is simple to use, fast, sensitive, robust, and can be directly applied to surface characterization using portable or high performance mass spectrometers. PMID:26486514

  13. Quantitative biomedical mass spectrometry

    NASA Astrophysics Data System (ADS)

    de Leenheer, Andrép; Thienpont, Linda M.

    1992-09-01

    The scope of this contribution is an illustration of the capabilities of isotope dilution mass spectrometry (IDMS) for quantification of target substances in the biomedical field. After a brief discussion of the general principles of quantitative MS in biological samples, special attention will be paid to new technological developments or trends in IDMS from selected examples from the literature. The final section will deal with the use of IDMS for accuracy assessment in clinical chemistry. Methodological aspects considered crucial for avoiding sources of error will be discussed.

  14. Bioaffinity Mass Spectrometry Screening.

    PubMed

    Yang, Ben; Feng, Yun Jiang; Vu, Hoan; McCormick, Brendan; Rowley, Jessica; Pedro, Liliana; Crowther, Gregory J; Van Voorhis, Wesley C; Forster, Paul I; Quinn, Ronald J

    2016-02-01

    Electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICR-MS or ESI-FTMS) was used to screen 192 natural product extracts and a 659-member natural product-based fragment library for bindings to a potential malaria drug target, Plasmodium falciparum Rab11a (PfRab11a, PF13_0119). One natural product extract and 11 fragments showed binding activity. A new natural product, arborside E, was identified from the active extract of Psydrax montigena as a weak binder. Its binding activity and inhibitory activity against PfRab11a were confirmed by ESI-FTMS titration experiments and an orthogonal enzyme assay. PMID:26773071

  15. Single event mass spectrometry

    DOEpatents

    Conzemius, Robert J.

    1990-01-16

    A means and method for single event time of flight mass spectrometry for analysis of specimen materials. The method of the invention includes pulsing an ion source imposing at least one pulsed ion onto the specimen to produce a corresponding emission of at least one electrically charged particle. The emitted particle is then dissociated into a charged ion component and an uncharged neutral component. The ion and neutral components are then detected. The time of flight of the components are recorded and can be used to analyze the predecessor of the components, and therefore the specimen material. When more than one ion particle is emitted from the specimen per single ion impact, the single event time of flight mass spectrometer described here furnis This invention was made with Government support under Contract No. W-7405-ENG82 awarded by the Department of Energy. The Government has certain rights in the invention.

  16. Unstable simple volatiles and gas chromatography-tandem mass spectrometry analysis of essential oil from the roots bark of Oplopanax horridus extracted by supercritical fluid extraction.

    PubMed

    Shao, Li; Bao, Mei-Hua; Ouyang, Dong-Sheng; Wang, Chong-Zhi; Yuan, Chun-Su; Zhou, Hong-Hao; Huang, Wei-Hua

    2014-01-01

    Volatile oil from the root bark of Oplopanax horridus is regarded to be responsible for the clinical uses of the title plant as a respiratory stimulant and expectorant. Therefore, a supercritical fluid extraction method was first employed to extract the volatile oil from the roots bark of O. horridus, which was subsequently analyzed by GC/MS. Forty-eight volatile compounds were identified by GC/MS analysis, including (S,E)-nerolidol (52.5%), τ-cadinol (21.6%) and S-falcarinol (3.6%). Accordingly, the volatile oil (100 g) was subjected to chromatographic separation and purification. As a result, the three compounds, (E)-nerolidol (2 g), τ-cadinol (62 mg) and S-falcarinol (21 mg), were isolated and purified from the volatile oil, the structures of which were unambiguously elucidated by detailed spectroscopic analysis including 1D- and 2D-NMR techniques. PMID:25438081

  17. Isotope dilution mass spectrometry

    NASA Astrophysics Data System (ADS)

    Heumann, Klaus G.

    1992-09-01

    In the past isotope dilution mass spectrometry (IDMS) has usually been applied using the formation of positive thermal ions of metals. Especially in calibrating other analytical methods and for the certification of standard reference materials this type of IDMS became a routine method. Today, the progress in this field lies in the determination of ultra trace amounts of elements, e.g. of heavy metals in Antarctic ice and in aerosols in remote areas down to the sub-pg g-1 and sub-pg m-3 levels respectively, in the analysis of uranium and thorium at concentrations of a few pg g-1 in sputter targets for the production of micro- electronic devices or in the determination of sub-picogram amounts of230Th in corals for geochemical age determinations and of226Ra in rock samples. During the last few years negative thermal ionization IDMS has become a frequently used method. The determination of very small amounts of selenium and technetium as well as of other transition metals such as vanadium, chromium, molybdenum and tungsten are important examples in this field. Also the measurement of silicon in connection with a re-determination of Avogadro's number and osmium analyses for geological age determinations by the Re/Os method are of special interest. Inductively-coupled plasma mass spectrometry is increasingly being used for multi-element analyses by the isotope dilution technique. Determinations of heavy metals in samples of marine origin are representative examples for this type of multi-element analysis by IDMS. Gas chromatography-mass spectrometry systems have also been successfully applied after chelation of metals (for example Pt determination in clinical samples) or for the determination of volatile element species in the environment, e.g. dimethyl sulfide. However, IDMS--specially at low concentration levels in the environment--seems likely to be one of the most powerful analytical methods for speciation in the future. This has been shown, up to now, for species of

  18. Development of a methodology for the simultaneous determination of inorganic and organolead compounds using supercritical fluid extraction followed by gas chromatography-mass spectrometry and its application to environmental matrices.

    PubMed

    Zúñiga, M C; Jover, E; Arancibia, V; Bayona, J M

    2009-12-15

    A method for the extraction of triethyl lead (TEL(+)), trimethyl lead (TML(+)), and Pb(2+) from sand was developed using supercritical modified CO(2)-CH(3)OH extraction and in situ complexation with sodium diethyldithiocarbamate (NaDDTC) using a 2(5) factorial exploratory design is described. The screened variables were (i) pressure (69-193 bar), (ii) temperature (40-150 degrees C), (iii) ligand amount (0-100 mg), (iv) methanol volume (0.0-0.5 mL) and (v) static time (0-45 min). The optimum extraction conditions found were as follow: pressure, 193 bar; temperature, 40 degrees C; amount of NaDDTC, 100 mg; methanol volume, 0.5 mL; static time 45 min; and CO(2) flow rate, 1 mL min(-1). Under these conditions the following recoveries were obtained (TML(+) 97+/-2%, TEL(+) 70+/-5%, and Pb(2+) 100+/-4%). The presence of NaDDTC is not necessary for the extraction of TML(+) and TEL(+), but it is a very significative parameter for Pb(2+). A second experimental design 2(2)+star for temperature and pressure was realized, but the results were not better than those of the first model. SFE extract derivatization was achieved with pentylmagnesium bromide, and target analyte determination was carried out by gas chromatography-mass spectrometry. Detection limits in the full-scan mode were 4, 10, and 39 pg as lead for TMPeL, TEPeL and PbPe(4), respectively. The method was validated with urban dust containing TML(+) (CRM 605. Pb 7.9 +/-1.2 microg kg(-1)) and river sediment containing inorganic lead (GBW08301. Pb 79.0+/-12.0 mg kg(-1)) as reference materials. The proposed method was applied to lead analysis in sand collected from an oil-polluted beach in Chile. PMID:19836512

  19. Simultaneous quantitation of the diastereoisomers of scholarisine and 19-epischolarisine, vallesamine, and picrinine in rat plasma by supercritical fluid chromatography with tandem mass spectrometry and its application to a pharmacokinetic study.

    PubMed

    Yang, Zhichao; Sun, Lingxia; Liang, Chunsu; Xu, Yongwei; Cao, Jianming; Yang, Yan; Gu, Jingkai

    2016-07-01

    Dengtaiye tablet has been used to treat chronic bronchitis cough. Scholarisine, 19-epischolarisine, vallesamine, and picrinine are the representative constituents of Dengtaiye. A rapid and sensitive assay based on supercritical fluid chromatography with tandem mass spectrometry has been developed and validated for the determination of the diastereoisomers of scholarisine and 19-epischolarisine, vallesamine, and picrinine in rat plasma using lamotrigine as internal standard. The analysis in a run time of only 6 min was performed on an ACQUITY UPC(2) Trefoil(TM) BEH 2-EP column (3.0 × 150 mm, 2.5 μm) at 50ºC. The mobile phase consisting of carbon dioxide and methanol (2 mM ammonium formate) was performed as follows: 15% methanol (2 mM ammonium formate) maintained at 0-2 min, 15-19% methanol (2 mM ammonium formate) at 2-4 min, 19-15% methanol (2 mM ammonium formate) at 4-6 min. The flow rate was 1.50 mL/min. The assay was linear over the concentration ranges 50-10000 pg/mL for scholarisine, 19-epischolarisine, vallesamine, and picrinine with corresponding lower limits of quantitation of 50 pg/mL. Intra- and interday precisions were in the range 1.42-12.85% with accuracies in the range -11.71-2.48%. The method was successfully applied to a pharmacokinetic study involving a single oral administration of 108 mg/kg Dengtaiye tablet to rats. PMID:27161345

  20. Nanopore Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Bush, Joseph; Mihovilovic, Mirna; Maulbetsch, William; Frenchette, Layne; Moon, Wooyoung; Pruitt, Cole; Bazemore-Walker, Carthene; Weber, Peter; Stein, Derek

    2013-03-01

    We report on the design, construction, and characterization of a nanopore-based ion source for mass spectrometry. Our goal is to field-extract ions directly from solution into the high vacuum to enable unit collection efficiency and temporal resolution of sequential ion emissions for DNA sequencing. The ion source features a capillary whose tip, measuring tens to hundreds of nanometers in inner diameter, is situated in the vacuum ~ 1.5 cm away from an extractor electrode. The capillary was filled with conductive solution and voltage-biased relative to the extractor. Applied voltages of hundreds of volts extracted tens to hundreds of nA of current from the tip. A mass analysis of the extracted ions showed primarily singly charged clusters comprising the cation or anion solvated by several solvent molecules. Our interpretation of these results, based on the works of Taylor and of de la Mora, is that the applied electric stresses distort the fluid meniscus into a Taylor cone, where electric fields reach ~ 1V/nm and induce significant ion evaporation. Accordingly, the abundances of extracted ionic clusters resemble a Boltzmann distribution. This work was supported by NIH grant NHGRI 1R21HG005100-01.

  1. Biomedical accelerator mass spectrometry

    NASA Astrophysics Data System (ADS)

    Freeman, Stewart P. H. T.; Vogel, John S.

    1995-05-01

    Ultrasensitive SIMS with accelerator based spectrometers has recently begun to be applied to biomedical problems. Certain very long-lived radioisotopes of very low natural abundances can be used to trace metabolism at environmental dose levels ( [greater-or-equal, slanted] z mol in mg samples). 14C in particular can be employed to label a myriad of compounds. Competing technologies typically require super environmental doses that can perturb the system under investigation, followed by uncertain extrapolation to the low dose regime. 41Ca and 26Al are also used as elemental tracers. Given the sensitivity of the accelerator method, care must be taken to avoid contamination of the mass spectrometer and the apparatus employed in prior sample handling including chemical separation. This infant field comprises the efforts of a dozen accelerator laboratories. The Center for Accelerator Mass Spectrometry has been particularly active. In addition to collaborating with groups further afield, we are researching the kinematics and binding of genotoxins in-house, and we support innovative uses of our capability in the disciplines of chemistry, pharmacology, nutrition and physiology within the University of California. The field can be expected to grow further given the numerous potential applications and the efforts of several groups and companies to integrate more the accelerator technology into biomedical research programs; the development of miniaturized accelerator systems and ion sources capable of interfacing to conventional HPLC and GMC, etc. apparatus for complementary chemical analysis is anticipated for biomedical laboratories.

  2. Development and optimization of ultra-high performance supercritical fluid chromatography mass spectrometry method for high-throughput determination of tocopherols and tocotrienols in human serum.

    PubMed

    Pilařová, Veronika; Gottvald, Tomáš; Svoboda, Pavel; Novák, Ondřej; Benešová, Karolína; Běláková, Sylvie; Nováková, Lucie

    2016-08-31

    The goal of this study was to develop an effective supercritical fluid chromatography method using single quadrupole MS for analysis of all isomeric forms of vitamin E. Finally, two fast and effective methods, the high resolution one and the high speed one, for the determination of 8 vitamin E isomers in human serum were developed. Rapid high-throughput liquid-liquid extraction was selected as a sample preparation step. Sample pretreatment of 100 μL human serum was consisted of protein precipitation with 200 μL ethanol and liquid-liquid extraction by 400 μL hexane/dichloromethane (80/20, v/v). The separation was performed on BEH 2-EP (3.0 × 100 mm, 1.7 μm) stationary phase, using isocratic elution with carbon dioxide and 10 mM ammonium formate in methanol in the ratio 98:2 for high resolution method with run time 4.5 min and in the ratio 95:5 for high speed method, where the run time was 2.5 min. The method development included optimization of key parameters: the choice of the suitable stationary phase and the composition of mobile phase, where an influence of various modifiers, their ratio and additives were tested, and optimization of fine tunning parameters including BPR pressure, flow-rate and column temperature. Quantification of all isomeric forms was performed using SIM (single ion monitoring) experiments in ESI positive ion mode. Both high speed and high resolution chromatographic methods were validated in terms of precision, accuracy, range, linearity, LOD, LOQ and matrix effects using the same LLE procedure. The high resolution method provided more sensitive results (LOD: 0.017-0.083 μg mL(-1)) and better linearity (r(2) > 0.9930) than the high speed one (LOD: 0.083-0.25 μg mL(-1), r(2) > 0.9877) at the cost of double time of analysis. PMID:27506367

  3. Ion mobility-mass spectrometry.

    PubMed

    Kanu, Abu B; Dwivedi, Prabha; Tam, Maggie; Matz, Laura; Hill, Herbert H

    2008-01-01

    This review article compares and contrasts various types of ion mobility-mass spectrometers available today and describes their advantages for application to a wide range of analytes. Ion mobility spectrometry (IMS), when coupled with mass spectrometry, offers value-added data not possible from mass spectra alone. Separation of isomers, isobars, and conformers; reduction of chemical noise; and measurement of ion size are possible with the addition of ion mobility cells to mass spectrometers. In addition, structurally similar ions and ions of the same charge state can be separated into families of ions which appear along a unique mass-mobility correlation line. This review describes the four methods of ion mobility separation currently used with mass spectrometry. They are (1) drift-time ion mobility spectrometry (DTIMS), (2) aspiration ion mobility spectrometry (AIMS), (3) differential-mobility spectrometry (DMS) which is also called field-asymmetric waveform ion mobility spectrometry (FAIMS) and (4) traveling-wave ion mobility spectrometry (TWIMS). DTIMS provides the highest IMS resolving power and is the only IMS method which can directly measure collision cross-sections. AIMS is a low resolution mobility separation method but can monitor ions in a continuous manner. DMS and FAIMS offer continuous-ion monitoring capability as well as orthogonal ion mobility separation in which high-separation selectivity can be achieved. TWIMS is a novel method of IMS with a low resolving power but has good sensitivity and is well intergrated into a commercial mass spectrometer. One hundred and sixty references on ion mobility-mass spectrometry (IMMS) are provided. PMID:18200615

  4. Linear electric field mass spectrometry

    DOEpatents

    McComas, D.J.; Nordholt, J.E.

    1992-12-01

    A mass spectrometer and methods for mass spectrometry are described. The apparatus is compact and of low weight and has a low power requirement, making it suitable for use on a space satellite and as a portable detector for the presence of substances. High mass resolution measurements are made by timing ions moving through a gridless cylindrically symmetric linear electric field. 8 figs.

  5. Linear electric field mass spectrometry

    DOEpatents

    McComas, David J.; Nordholt, Jane E.

    1992-01-01

    A mass spectrometer and methods for mass spectrometry. The apparatus is compact and of low weight and has a low power requirement, making it suitable for use on a space satellite and as a portable detector for the presence of substances. High mass resolution measurements are made by timing ions moving through a gridless cylindrically symmetric linear electric field.

  6. Mass spectrometry. [in organic chemistry

    NASA Technical Reports Server (NTRS)

    Burlingame, A. L.; Shackleton, C. H. L.; Howe, I.; Chizhov, O. S.

    1978-01-01

    A review of mass spectrometry in organic chemistry is given, dealing with advances in instrumentation and computer techniques, selected topics in gas-phase ion chemistry, and applications in such fields as biomedicine, natural-product studies, and environmental pollution analysis. Innovative techniques and instrumentation are discussed, along with chromatographic-mass spectrometric on-line computer techniques, mass spectral interpretation and management techniques, and such topics in gas-phase ion chemistry as electron-impact ionization and decomposition, photoionization, field ionization and desorption, high-pressure mass spectrometry, ion cyclotron resonance, and isomerization reactions of organic ions. Applications of mass spectrometry are examined with respect to bio-oligomers and their constituents, biomedically important substances, microbiology, environmental organic analysis, and organic geochemistry.

  7. Instrumentation for mass spectrometry: 1997

    SciTech Connect

    McLuckey, S.A.

    1997-08-01

    All mass spectrometry experiments involve the manipulation of material, an interface with the mass spectrometer, ionization, ion manipulation/analysis, detection and data collection/reduction. Each of these elements involve instrumentation. The wide range of species now amenable to mass spectrometry and the diverse areas of physical science in which it plays a role have led to a seemingly unlimited array of instrumental combinations. However, only a limited number of mass analyzers, and their combinations, dominate. The dominant analyzers include time-of-flight, Fourier transform ion cyclotron resonance, the Paul trap, the mass filter, and the sector mass spectrometer. Why there are so few (or so many, depending upon one`s point of view) can be understood upon consideration of a set of mass analyzer figures of merit. These include mass resolution, mass accuracy, mass range, dynamic range, abundance sensitivity, precision, efficiency, speed, MS{sup n} capability, compatibility with the ionizer, cost, and size. The most appropriate form of mass spectrometry is determined by the priorities of the particular measurement placed on the various mass analyzer characteristics and the relative strengths of the analyzers in meeting the requirements. Each of the analyzer types has a unique set of figures of merit that makes it optimally suited for particular applications. This paper discusses these figures of merit, provides data illustrating recent developments for each analyzer type, and gives the figures of merit of each type of analyzer as they stand in 1997. 101 refs., 24 figs.

  8. Digital Imaging Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Bamberger, Casimir; Renz, Uwe; Bamberger, Andreas

    2011-06-01

    Methods to visualize the two-dimensional (2D) distribution of molecules by mass spectrometric imaging evolve rapidly and yield novel applications in biology, medicine, and material surface sciences. Most mass spectrometric imagers acquire high mass resolution spectra spot-by-spot and thereby scan the object's surface. Thus, imaging is slow and image reconstruction remains cumbersome. Here we describe an imaging mass spectrometer that exploits the true imaging capabilities by ion optical means for the time of flight mass separation. The mass spectrometer is equipped with the ASIC Timepix chip as an array detector to acquire the position, mass, and intensity of ions that are imaged by matrix-assisted laser desorption/ionization (MALDI) directly from the target sample onto the detector. This imaging mass spectrometer has a spatial resolving power at the specimen of (84 ± 35) μm with a mass resolution of 45 and locates atoms or organic compounds on a surface area up to ~2 cm2. Extended laser spots of ~5 mm2 on structured specimens allows parallel imaging of selected masses. The digital imaging mass spectrometer proves high hit-multiplicity, straightforward image reconstruction, and potential for high-speed readout at 4 kHz or more. This device demonstrates a simple way of true image acquisition like a digital photographic camera. The technology may enable a fast analysis of biomolecular samples in near future.

  9. Ion Trap Mass Spectrometry

    SciTech Connect

    Eiden, Greg C.

    2005-09-01

    This chapter describes research conducted in a few research groups in the 1990s in which RF quadrupole ion trap mass spectrometers were coupled to a powerful atomic ion source, the inductively coupled plasma used in conventional ICP-MS instruments. Major section titles for this chapter are: RF Quadrupole Ion Traps Features of RF Quadrupole Ion Trap Mass Spectrometers Selective Ion Trapping methods Inductively Coupled Plasma Source Ion Trap Mass Spectrometers

  10. Symposium on accelerator mass spectrometry

    SciTech Connect

    1981-01-01

    The area of accelerator mass spectrometry has expanded considerably over the past few years and established itself as an independent and interdisciplinary research field. Three years have passed since the first meeting was held at Rochester. A Symposium on Accelerator Mass Spectrometry was held at Argonne on May 11-13, 1981. In attendance were 96 scientists of whom 26 were from outside the United States. The present proceedings document the program and excitement of the field. Papers are arranged according to the original program. A few papers not presented at the meeting have been added to complete the information on the status of accelerator mass spectrometry. Individual papers were prepared separately for the data base.

  11. Mass spectrometry for biomarker development

    SciTech Connect

    Wu, Chaochao; Liu, Tao; Baker, Erin Shammel; Rodland, Karin D.; Smith, Richard D.

    2015-06-19

    Biomarkers potentially play a crucial role in early disease diagnosis, prognosis and targeted therapy. In the past decade, mass spectrometry based proteomics has become increasingly important in biomarker development due to large advances in technology and associated methods. This chapter mainly focuses on the application of broad (e.g. shotgun) proteomics in biomarker discovery and the utility of targeted proteomics in biomarker verification and validation. A range of mass spectrometry methodologies are discussed emphasizing their efficacy in the different stages in biomarker development, with a particular emphasis on blood biomarker development.

  12. Ion Mobility Spectrometry (IMS) and Mass Spectrometry

    SciTech Connect

    Shvartsburg, Alexandre A.

    2010-04-20

    In a media of finite viscosity, the Coulomb force of external electric field moves ions with some terminal speed. This dynamics is controlled by “mobility” - a property of the interaction potential between ions and media molecules. This fact has been used to separate and characterize gas-phase ions in various modes of ion mobility spectrometry (IMS) developed since 1970. Commercial IMS devices were introduced in 1980-s for field detection of volatile traces such as explosives and chemical warfare agents. Coupling to soft-ionization sources, mass spectrometry (MS), and chromatographic methods in 1990-s had allowed IMS to handle complex samples, enabling new applications in biological and environmental analyses, nanoscience, and other areas. Since 2003, the introduction of commercial systems by major instrument vendors started bringing the IMS/MS capability to broad user community. The other major development of last decade has been the differential IMS or “field asymmetric waveform IMS” (FAIMS) that employs asymmetric time-dependent electric field to sort ions not by mobility itself, but by the difference between its values in strong and weak electric fields. Coupling of FAIMS to conventional IMS and stacking of conventional IMS stages have enabled two-dimensional separations that dramatically expand the power of ion mobility methods.

  13. Mass spectrometry of large complexes.

    PubMed

    Bich, Claudia; Zenobi, Renato

    2009-10-01

    Mass spectrometry is becoming a more and more powerful tool for investigating protein complexes. Recent developments, based on different ionization techniques, electrospray, desorption/ionization and others are contributing to the usefulness of MS to describe the organization and structure of large non-covalent assemblies. PMID:19782560

  14. Electrospray Ionization Mass Spectrometry

    SciTech Connect

    Kelly, Ryan T.; Marginean, Ioan; Tang, Keqi

    2014-06-13

    Electrospray Ionization (ESI) is a process whereby gas phase ions are created from molecules in solution. As a solution exits a narrow tube in the presence of a strong electric field, an aerosol of charged droplets are is formed that produces gas phase ions as they it desolvates. ESI-MS comprises the creation of ions by ESI and the determination of their mass to charge ratio (m/z) by MS.

  15. Accelerator mass spectrometry

    SciTech Connect

    Vogel, J.S.; Turteltaub, K.W.; Finkel, R.; Nelson, D.E.

    1995-06-01

    Accelerator mass spectroscopy (AMS) can be used for efficient detection of long-lived isotopes at part-per-quadrillion sensitivities with good precision. In this article we present an overview of AMS and its recent use in archaeology, geochemistry and biomolecular tracing. All AMS systems use cesium sputter ion sources to produce negative ions from a small button of a solid sample containing the element of interest, such as graphite, metal halide, or metal oxide, often mixed with a metal powder as binder and thermal conductor. Experience shows that both natural and biomedical samples are compatible in a single AMS system, but few other AMS sites make routine {sup 14}C measurements for both dating and tracing. AMS is, in one sense, just `a very sensitive decay counter`, but if AMS sensitivity is creatively coupled to analytical chemistry of certain isotopes, whole new areas of geosciences, archaeology, and life sciences can be explored. 29 refs., 2 figs., 1 tab.

  16. Ambient Ionization Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Huang, Min-Zong; Yuan, Cheng-Hui; Cheng, Sy-Chyi; Cho, Yi-Tzu; Shiea, Jentaie

    2010-07-01

    Mass spectrometric ionization methods that operate under ambient conditions and require minimal or no sample pretreatment have attracted much attention in such fields as biomedicine, food safety, antiterrorism, pharmaceuticals, and environmental pollution. These technologies usually involve separate ionization and sample-introduction events, allowing independent control over each set of conditions. Ionization is typically performed under ambient conditions through use of existing electrospray ionization (ESI) or atmospheric pressure chemical ionization (APCI) techniques. Rapid analyses of gas, liquid, and solid samples are possible with the adoption of various sample-introduction methods. This review sorts different ambient ionization techniques into two main subcategories, primarily on the basis of the ionization processes, that are further differentiated in terms of the approach used for sampling.

  17. MASS SPECTROMETRY-BASED METABOLOMICS

    PubMed Central

    Dettmer, Katja; Aronov, Pavel A.; Hammock, Bruce D.

    2007-01-01

    This review presents an overview of the dynamically developing field of mass spectrometry-based metabolomics. Metabolomics aims at the comprehensive and quantitative analysis of wide arrays of metabolites in biological samples. These numerous analytes have very diverse physico-chemical properties and occur at different abundance levels. Consequently, comprehensive metabolomics investigations are primarily a challenge for analytical chemistry and specifically mass spectrometry has vast potential as a tool for this type of investigation. Metabolomics require special approaches for sample preparation, separation, and mass spectrometric analysis. Current examples of those approaches are described in this review. It primarily focuses on metabolic fingerprinting, a technique that analyzes all detectable analytes in a given sample with subsequent classification of samples and identification of differentially expressed metabolites, which define the sample classes. To perform this complex task, data analysis tools, metabolite libraries, and databases are required. Therefore, recent advances in metabolomics bioinformatics are also discussed. PMID:16921475

  18. Mass spectrometry and renal calculi

    PubMed Central

    Purcarea, VL; Sisu, I; Sisu, E

    2010-01-01

    The present review represents a concise and complete survey of the literature covering 2004–2009, concerning the mass spectrometric techniques involved in the structural investigation of renal calculi. After a short presentation of the fundamental mass spectrometric techniques (MALDI–TOF, QTOF, MS–MS) as well as hyphenated methods (GC–MS, LC–MS, CE–MS), an extensive study of the urinary proteome analysis as well as the detection and quantification by mass spectrometry of toxins, drugs and metabolites from renal calculi is presented. PMID:20968197

  19. Mass spectrometry of aerospace materials

    NASA Technical Reports Server (NTRS)

    Colony, J. A.

    1976-01-01

    Mass spectrometry is used for chemical analysis of aerospace materials and contaminants. Years of analytical aerospace experience have resulted in the development of specialized techniques of sampling and analysis which are required in order to optimize results. This work has resulted in the evolution of a hybrid method of indexing mass spectra which include both the largest peaks and the structurally significant peaks in a concise format. With this system, a library of mass spectra of aerospace materials was assembled, including the materials responsible for 80 to 90 percent of the contamination problems at Goddard Space Flight Center during the past several years.

  20. Imaging Mass Spectrometry in Neuroscience

    PubMed Central

    2013-01-01

    Imaging mass spectrometry is an emerging technique of great potential for investigating the chemical architecture in biological matrices. Although the potential for studying neurobiological systems is evident, the relevance of the technique for application in neuroscience is still in its infancy. In the present Review, a principal overview of the different approaches, including matrix assisted laser desorption ionization and secondary ion mass spectrometry, is provided with particular focus on their strengths and limitations for studying different neurochemical species in situ and in vitro. The potential of the various approaches is discussed based on both fundamental and biomedical neuroscience research. This Review aims to serve as a general guide to familiarize the neuroscience community and other biomedical researchers with the technique, highlighting its great potential and suitability for comprehensive and specific chemical imaging. PMID:23530951

  1. Glycosaminoglycan Glycomics Using Mass Spectrometry*

    PubMed Central

    Zaia, Joseph

    2013-01-01

    The fact that sulfated glycosaminoglycans (GAGs) are necessary for the functioning of all animal physiological systems drives the need to understand their biology. This understanding is limited, however, by the heterogeneous nature of GAG chains and their dynamic spatial and temporal expression patterns. GAGs have a regulated structure overlaid by heterogeneity but lack the detail necessary to build structure/function relationships. In order to provide this information, we need glycomics platforms that are sensitive, robust, high throughput, and information rich. This review summarizes progress on mass-spectrometry-based GAG glycomics methods. The areas covered include disaccharide analysis, oligosaccharide profiling, and tandem mass spectrometric sequencing. PMID:23325770

  2. Mass spectrometry. [review of techniques

    NASA Technical Reports Server (NTRS)

    Burlingame, A. L.; Kimble, B. J.; Derrick, P. J.

    1976-01-01

    Advances in mass spectrometry (MS) and its applications over the past decade are reviewed in depth, with annotated literature references. New instrumentation and techniques surveyed include: modulated-beam MS, chromatographic MS on-line computer techniques, digital computer-compatible quadrupole MS, selected ion monitoring (mass fragmentography), and computer-aided management of MS data and interpretation. Areas of application surveyed include: organic MS and electron impact MS, field ionization kinetics, appearance potentials, translational energy release, studies of metastable species, photoionization, calculations of molecular orbitals, chemical kinetics, field desorption MS, high pressure MS, ion cyclotron resonance, biochemistry, medical/clinical chemistry, pharmacology, and environmental chemistry and pollution studies.

  3. A mass spectrometry primer for mass spectrometry imaging

    PubMed Central

    Rubakhin, Stanislav S.; Sweedler, Jonathan V.

    2011-01-01

    Mass spectrometry imaging (MSI), a rapidly growing subfield of chemical imaging, employs mass spectrometry (MS) technologies to create single- and multi-dimensional localization maps for a variety of atoms and molecules. Complimentary to other imaging approaches, MSI provides high chemical specificity and broad analyte coverage. This powerful analytical toolset is capable of measuring the distribution of many classes of inorganics, metabolites, proteins and pharmaceuticals in chemically and structurally complex biological specimens in vivo, in vitro, and in situ. The MSI approaches highlighted in this Methods in Molecular Biology volume provide flexibility of detection, characterization, and identification of multiple known and unknown analytes. The goal of this chapter is to introduce investigators who may be unfamiliar with MS to the basic principles of the mass spectrometric approaches as used in MSI. In addition to guidelines for choosing the most suitable MSI method for specific investigations, cross-references are provided to the chapters in this volume that describe the appropriate experimental protocols. PMID:20680583

  4. Electrophoresis-mass spectrometry probe

    DOEpatents

    Andresen, B.D.; Fought, E.R.

    1987-11-10

    The invention involves a new technique for the separation of complex mixtures of chemicals, which utilizes a unique interface probe for conventional mass spectrometers which allows the electrophoretically separated compounds to be analyzed in real-time by a mass spectrometer. This new chemical analysis interface, which couples electrophoresis with mass spectrometry, allows complex mixtures to be analyzed very rapidly, with much greater specificity, and with greater sensitivity. The interface or probe provides a means whereby large and/or polar molecules in complex mixtures to be completely characterized. The preferred embodiment of the probe utilizes a double capillary tip which allows the probe tip to be continually wetted by the buffer, which provides for increased heat dissipation, and results in a continually operating interface which is more durable and electronically stable than the illustrated single capillary tip probe interface. 8 figs.

  5. Electrophoresis-mass spectrometry probe

    DOEpatents

    Andresen, Brian D.; Fought, Eric R.

    1987-01-01

    The invention involves a new technique for the separation of complex mixtures of chemicals, which utilizes a unique interface probe for conventional mass spectrometers which allows the electrophoretically separated compounds to be analyzed in real-time by a mass spectrometer. This new chemical analysis interface, which couples electrophoresis with mass spectrometry, allows complex mixtures to be analyzed very rapidly, with much greater specificity, and with greater sensitivity. The interface or probe provides a means whereby large and/or polar molecules in complex mixtures to be completely characterized. The preferred embodiment of the probe utilizes a double capillary tip which allows the probe tip to be continually wetted by the buffer, which provides for increased heat dissipation, and results in a continually operating interface which is more durable and electronically stable than the illustrated single capillary tip probe interface.

  6. Plasma mass spectrometry as a detector for chemical speciation studies.

    PubMed

    Tomlinson, M J; Lin, L; Caruso, J A

    1995-03-01

    Inductively coupled plasma mass spectrometry (ICP-MS), when coupled with the unique separating power of various chromatographic techniques, allows the detection of various elements at ultra-trace levels. The investigation of various toxic elements of environmental concern coupling relatively recent techniques, such as supercritical fluid chromatography (SFC) and capillary zone electrophoresis (CZE), to ICP-MS, is discussed. Comparisons have been made with detection limits obtained by using the flame ionization detector. The conventional technique of liquid chromatography for the speciation of vanadium, chromium and nickel is also discussed. PMID:7741220

  7. Neuroscience and Accelerator Mass Spectrometry

    SciTech Connect

    Palmblad, M N; Buchholz, B A; Hillegonds, D J; Vogel, J S

    2004-08-02

    Accelerator mass spectrometry (AMS) is a mass spectrometric method for quantifying rare isotopes. It has had great impact in geochronology and archaeology and is now being applied in biomedicine. AMS measures radioisotopes such as {sup 3}H, {sup 14}C, {sup 26}Al, {sup 36}Cl and {sup 41}Ca, with zepto- or attomole sensitivity and high precision and throughput, enabling safe human pharmacokinetic studies involving: microgram doses, agents having low bioavailability, or toxicology studies where administered doses must be kept low (<1 {micro}g/kg). It is used to study long-term pharmacokinetics, to identify biomolecular interactions, to determine chronic and low-dose effects or molecular targets of neurotoxic substances, to quantify transport across the blood-brain barrier and to resolve molecular turnover rates in the human brain on the timescale of decades. We will here review how AMS is applied in neurotoxicology and neuroscience.

  8. The life sciences mass spectrometry research unit.

    PubMed

    Hopfgartner, Gérard; Varesio, Emmanuel

    2012-01-01

    The Life Sciences Mass Spectrometry (LSMS) research unit focuses on the development of novel analytical workflows based on innovative mass spectrometric and software tools for the analysis of low molecular weight compounds, peptides and proteins in complex biological matrices. The present article summarizes some of the recent work of the unit: i) the application of matrix-assisted laser desorption/ionization (MALDI) for mass spectrometry imaging (MSI) of drug of abuse in hair, ii) the use of high resolution mass spectrometry for simultaneous qualitative/quantitative analysis in drug metabolism and metabolomics, and iii) the absolute quantitation of proteins by mass spectrometry using the selected reaction monitoring mode. PMID:22867547

  9. MASS SPECTROMETRY OF FATTY ALDEHYDES

    PubMed Central

    Berdyshev, Evgeny V.

    2011-01-01

    Fatty aldehydes are important components of the cellular lipidome. Significant interest has been developed towards the analysis of the short chain α,β-unsaturated and hydroxylated aldehydes formed as a result of oxidation of polyunsaturated fatty acids. Multiple gas chromatography-mass spectrometry (GC/MS) and subsequently liquid chromatography-mass spectrometry (LC/MS) approaches have been developed to identify and quantify short-chain as well as long-chain fatty aldehydes. Due to the ability to non-enzymaticaly form Schiff bases with amino groups of proteins, lipids, and with DNA guanidine, free aldehydes are viewed as a marker or metric of fatty acid oxidation and not the part of intracellular signaling pathways which has significantly limited the overall attention this group of molecules have received. This review provides an overview of current GC/MS and LC/MS approaches of fatty aldehyde analysis as well as discusses technical challenges standing in the way of free fatty aldehyde quantitation. PMID:21930240

  10. Counting Molecules by Desorption Ionization and Mass Spectrometry/Mass Spectrometry.

    ERIC Educational Resources Information Center

    Cooks, R. G.; Busch, K. L.

    1982-01-01

    Discusses two newer methods in mass spectrometry and shows how they can increase signal and signal-to-noise ratios, respectively. The first method, desorption ionization (DI), increases sensitivity while the second method, mass spectrometry/mass spectrometry (MS/MS), increases specificity. Together, the two methods offer improved analytical…

  11. Nanotip Ambient Ionization Mass Spectrometry.

    PubMed

    Zhou, Zhenpeng; Lee, Jae Kyoo; Kim, Samuel C; Zare, Richard N

    2016-05-17

    A method called nanotip ambient ionization mass spectrometry (NAIMS) is described, which applies high voltage between a tungsten nanotip and a metal plate to generate a plasma in which ionized analytes on the surface of the metal plate are directed to the inlet and analyzed by a mass spectrometer. The dependence of signal intensity is investigated as a function of the tip-to-plate distance, the tip size, the voltage applied at the tip, and the current. These parameters are separately optimized to achieve sensitivity or high spatial resolution. A partially observable Markov decision process is used to achieve a stabilized plasma as well as high ionization efficiency. As a proof of concept, the NAIMS technique has been applied to phenanthrene and caffeine samples for which the limits of detection were determined to be 0.14 fmol for phenanthrene and 4 amol for caffeine and to a printed caffeine pattern for which a spatial resolution of 8 ± 2 μm, and the best resolution of 5 μm, was demonstrated. The limitations of NAIMS are also discussed. PMID:27087600

  12. Developments in ion mobility spectrometry-mass spectrometry.

    PubMed

    Collins, D C; Lee, M L

    2002-01-01

    Ion mobility spectrometry (IMS) has been used for over 30 years as a sensitive detector of organic compounds. The following is a brief review of IMS and its principles with an emphasis on its usage when coupled to mass spectrometry. Since its inception, IMS has been interfaced with quadrupole, time-of-flight, and Fourier-transform ion cyclotron resonance mass spectrometry. These hybrid instruments have been employed for the analysis of a variety of target analytes, including biomolecules, explosives, chemical warfare degradation products, and illicit drugs. PMID:11939214

  13. Inorganic trace analysis by mass spectrometry

    NASA Astrophysics Data System (ADS)

    Becker, Johanna Sabine; Dietze, Hans-Joachim

    1998-10-01

    Mass spectrometric methods for the trace analysis of inorganic materials with their ability to provide a very sensitive multielemental analysis have been established for the determination of trace and ultratrace elements in high-purity materials (metals, semiconductors and insulators), in different technical samples (e.g. alloys, pure chemicals, ceramics, thin films, ion-implanted semiconductors), in environmental samples (waters, soils, biological and medical materials) and geological samples. Whereas such techniques as spark source mass spectrometry (SSMS), laser ionization mass spectrometry (LIMS), laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), glow discharge mass spectrometry (GDMS), secondary ion mass spectrometry (SIMS) and inductively coupled plasma mass spectrometry (ICP-MS) have multielemental capability, other methods such as thermal ionization mass spectrometry (TIMS), accelerator mass spectrometry (AMS) and resonance ionization mass spectrometry (RIMS) have been used for sensitive mono- or oligoelemental ultratrace analysis (and precise determination of isotopic ratios) in solid samples. The limits of detection for chemical elements using these mass spectrometric techniques are in the low ng g -1 concentration range. The quantification of the analytical results of mass spectrometric methods is sometimes difficult due to a lack of matrix-fitted multielement standard reference materials (SRMs) for many solid samples. Therefore, owing to the simple quantification procedure of the aqueous solution, inductively coupled plasma mass spectrometry (ICP-MS) is being increasingly used for the characterization of solid samples after sample dissolution. ICP-MS is often combined with special sample introduction equipment (e.g. flow injection, hydride generation, high performance liquid chromatography (HPLC) or electrothermal vaporization) or an off-line matrix separation and enrichment of trace impurities (especially for characterization of

  14. Characterization of microbial siderophores by mass spectrometry.

    PubMed

    Pluháček, Tomáš; Lemr, Karel; Ghosh, Dipankar; Milde, David; Novák, Jiří; Havlíček, Vladimír

    2016-01-01

    Siderophores play important roles in microbial iron piracy, and are applied as infectious disease biomarkers and novel pharmaceutical drugs. Inductively coupled plasma and molecular mass spectrometry (ICP-MS) combined with high resolution separations allow characterization of siderophores in complex samples taking advantages of mass defect data filtering, tandem mass spectrometry, and iron-containing compound quantitation. The enrichment approaches used in siderophore analysis and current ICP-MS technologies are reviewed. The recent tools for fast dereplication of secondary metabolites and their databases are reported. This review on siderophores is concluded with their recent medical, biochemical, geochemical, and agricultural applications in mass spectrometry context. PMID:25980644

  15. Broadband Analysis of Bioagents by Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Fenselau, Catherine; Wynne, Colin; Edwards, Nathan

    Mass spectrometry was first reported to provide analysis of intact metabolite biomarkers from whole cells in 1975.1 Since then advances in ionization techniques have extended our capabilities to polar lipids and, eventually, to proteins.2, 3 Mass spectrometry provides a broadband detection system, which, however, has great specificity. Bioinformatics plays an important role in providing flexible and rapid characterization of species, based on protein and peptide mass spectra collected in the field.

  16. Methods for recalibration of mass spectrometry data

    DOEpatents

    Tolmachev, Aleksey V.; Smith, Richard D.

    2009-03-03

    Disclosed are methods for recalibrating mass spectrometry data that provide improvement in both mass accuracy and precision by adjusting for experimental variance in parameters that have a substantial impact on mass measurement accuracy. Optimal coefficients are determined using correlated pairs of mass values compiled by matching sets of measured and putative mass values that minimize overall effective mass error and mass error spread. Coefficients are subsequently used to correct mass values for peaks detected in the measured dataset, providing recalibration thereof. Sub-ppm mass measurement accuracy has been demonstrated on a complex fungal proteome after recalibration, providing improved confidence for peptide identifications.

  17. Plasma Desorption Mass Spectrometry: Coming of Age.

    ERIC Educational Resources Information Center

    Cotter, Robert J.

    1988-01-01

    Discusses the history and development of Plasma Desorption Mass Spectrometry to determine molecular weights and structures of proteins and polymers. Outlines theory, instrumentation, and sample preparation commonly used. Gives several examples of resulting spectra. (ML)

  18. Laser ablation inductively coupled plasma mass spectrometry

    SciTech Connect

    Durrant, S.F.

    1996-07-01

    Laser ablation for solid sample introduction to inductively coupled plasma mass spectrometry for bulk and spatially-resolved elemental analysis is briefly reviewed. {copyright} {ital 1996 American Institute of Physics.}

  19. Mass transfer in supercritical fluids instancing selected fluids in supercritical carbon dioxide

    NASA Astrophysics Data System (ADS)

    Hu, Miao; Benning, Rainer; Delgado, Antonio; Ertunc, Oezguer

    The research interests lie in a deeper understanding of the mechanisms of diffusion and nucle-ation of organic solutes in near-and supercritical state of a solvent, which count as important means of mass transfer in the process engineering industry. The use of supercritical fluids in industrial processes, such as extraction and particle handling, has become a more and more popular method. Take a closer look at the two processes one would find that there are obviously two sub-processes involved in each of the process, namely the diffusion/nucleation as well as a phase transition procedure. Because of the operational limitations in the practice, this phase transition can-not be neglected. So it is also included in the theoretical approach. Classically to deduce conclusions from experiment results, mathematical/physical models outlining property changes and summarizing characteristics of the two processes are expected. In order to become an insight of these phenomena from the origin, and also to serve as a fundamental attribute for the numerical simulation later, the theories of statistical thermodynamics are adopted here as a proper means to describe the behaviors of the two processes. As the diffusion coefficients of the samples in our case are only of an order of approx. 10-8m2s-1, it can be assumed that the processes are in equilibrium (local changes are neglectably small), a model can be built on a general macroscopic approach for equilibrium systems, namely the Boltzmann-Gibbs distri-bution. And some rather general methods e.g. linear response theory can be applied. But as the transfer phenomena are genuinely not equilibrium systems, from this aspect a model can also be built based on the microscopic description -the kinetic theory of the behaviors of the particles of this non-equilibrium system. The characteristics under compensated gravity are also to be considered in the models. The differences and constraints between the models are to be compared and

  20. Mass Spectrometry in the Home and Garden

    NASA Astrophysics Data System (ADS)

    Pulliam, Christopher J.; Bain, Ryan M.; Wiley, Joshua S.; Ouyang, Zheng; Cooks, R. Graham

    2015-02-01

    Identification of active components in a variety of chemical products used directly by consumers is described at both trace and bulk levels using mass spectrometry. The combination of external ambient ionization with a portable mass spectrometer capable of tandem mass spectrometry provides high chemical specificity and sensitivity as well as allowing on-site monitoring. These experiments were done using a custom-built portable ion trap mass spectrometer in combination with the ambient ionization methods of paper spray, leaf spray, and low temperature plasma ionization. Bactericides, garden chemicals, air fresheners, and other products were examined. Herbicide applied to suburban lawns was detected in situ on single leaves 5 d after application.

  1. Microorganism characterization by single particle mass spectrometry.

    PubMed

    Russell, Scott C

    2009-01-01

    In recent years a major effort by several groups has been undertaken to identify bacteria by mass spectrometry at the single cell level. The intent of this review is to highlight the recent progress made in the application of single particle mass spectrometry to the analysis of microorganisms. A large portion of the review highlights improvements in the ionization and mass analysis of bio-aerosols, or particles that contain biologically relevant molecules such as peptides or proteins. While these are not direct applications to bacteria, the results have been central to a progression toward single cell mass spectrometry. Developments in single particle matrix-assisted laser desorption/ionization (MALDI) are summarized. Recent applications of aerosol laser desorption/ionization (LDI) to the analysis of single microorganisms are highlighted. Successful applications of off-line and on-the-fly aerosol MALDI to microorganism detection are discussed. Limitations to current approaches and necessary future achievements are also addressed. PMID:18949817

  2. Mass Spectrometry of Intact Membrane Protein Complexes

    PubMed Central

    Laganowsky, Arthur; Reading, Eamonn; Hopper, Jonathan T.S.; Robinson, Carol V.

    2014-01-01

    Mass spectrometry of intact soluble protein complexes has emerged as a powerful technique to study the stoichiometry, structure-function and dynamics of protein assemblies. Recent developments have extended this technique to the study of membrane protein complexes where it has already revealed subunit stoichiometries and specific phospholipid interactions. Here, we describe a protocol for mass spectrometry of membrane protein complexes. The protocol begins with preparation of the membrane protein complex enabling not only the direct assessment of stoichiometry, delipidation, and quality of the target complex, but also evaluation of the purification strategy. A detailed list of compatible non-ionic detergents is included, along with a protocol for screening detergents to find an optimal one for mass spectrometry, biochemical and structural studies. This protocol also covers the preparation of lipids for protein-lipid binding studies and includes detailed settings for a Q-ToF mass spectrometer after introduction of complexes from gold-coated nanoflow capillaries. PMID:23471109

  3. Analytical aspects of hydrogen exchange mass spectrometry

    PubMed Central

    Engen, John R.; Wales, Thomas E.

    2016-01-01

    The analytical aspects of measuring hydrogen exchange by mass spectrometry are reviewed. The nature of analytical selectivity in hydrogen exchange is described followed by review of the analytical tools required to accomplish fragmentation, separation, and the mass spectrometry measurements under restrictive exchange quench conditions. In contrast to analytical quantitation that relies on measurements of peak intensity or area, quantitation in hydrogen exchange mass spectrometry depends on measuring a mass change with respect to an undeuterated or deuterated control, resulting in a value between zero and the maximum amount of deuterium that could be incorporated. Reliable quantitation is a function of experimental fidelity and to achieve high measurement reproducibility, a large number of experimental variables must be controlled during sample preparation and analysis. The method also reports on important qualitative aspects of the sample, including conformational heterogeneity and population dynamics. PMID:26048552

  4. STRUCTURAL CHARACTERIZATION OF SULFONATED AZO DYES USING LIQUID SECONDARY ION MASS SPECTROMETRY/TANDEM MASS SPECTROMETRY

    EPA Science Inventory

    Eight monosulfonated and disulfonated azo dyes were analyzed using liquid secondary ion mass spectrometry/tandem mass spectrometry, in the negative ion mode, under low-energy conditions (110-150 eV). any structurally characteristic fragment ions were obtained, several of which ha...

  5. Mass spectrometry and the environmental sciences

    NASA Astrophysics Data System (ADS)

    Hites, Ronald A.

    1992-09-01

    Research in environmental mass spectrometry focuses on two broad areas: development of new methods for a wide range of pollutants; and using existing methods to understand the fate of pollutants in nature. This paper will present examples of both types of research. In some environmental settings it is important to have rapid analytical turnaround, which suggests that samples should be analyzed in the field rather than in a remote laboratory. Thus, there has been considerable interest in "fieldable" mass spectrometers. Volatile and water soluble analytes can be introduced into a mass spectrometer by passing the water sample over a semi-permeable membrane. The analytes of interest pass through the membrane, but the water does not. This method may be useful in situations that require a continuous readout of concentration. Like mass spectrometrists everywhere, environmental scientists have explored the many facets of liquid chromatographic mass spectrometry. Work in our laboratory has centered on continuous flow fast atom bombardment (CF-FAB) as the LCMS interface. In addition, flow injection analysis is possible using CF-FAB. By avoiding chromatographic separation, the throughput of the analytical system is increased. Frequently, tandem mass spectrometry is necessary to unscramble the chemical signals produced by this technique. Electron capture negative ionization mass spectrometry can achieve sensitivities of a few attomoles for selected compounds; furthermore, the technique can be remarkably specific. These features make it ideal for the analysis of highly chlorinated environmental contaminants such as chlorinated dioxins. Such an application will be presented in detail.

  6. Mass spectrometry in natural product chemistry.

    PubMed

    Clayton, E; Hill, H C; Reed, R I

    1966-01-01

    Some mass spectrometric techniques are described which seem applicable to investigating problems in natural product chemistry. One example is of a sample of 5 mcg of a compound being identified by comparison with an authentic sample of prostaglandin derivative. Compared were mass, ion content, and structure. In the prostaglandin/unknown substance comparison, high-resolution mass spectrometry resolved a quandary: apparent additional ions present in the unknown substance were shown to be an impurity. PMID:12262324

  7. Capillary electrophoresis electrospray ionization mass spectrometry interface

    SciTech Connect

    Smith, R.D.; Severs, J.C.

    1999-11-30

    The present invention is an interface between a capillary electrophoresis separation capillary end and an electrospray ionization mass spectrometry emitter capillary end, for transporting an analyte sample from a capillary electrophoresis separation capillary to a electrospray ionization mass spectrometry emitter capillary. The interface of the present invention has: (a) a charge transfer fitting enclosing both of the capillary electrophoresis capillary end and the electrospray ionization mass spectrometry emitter capillary end; (b) a reservoir containing an electrolyte surrounding the charge transfer fitting; and (c) an electrode immersed into the electrolyte, the electrode closing a capillary electrophoresis circuit and providing charge transfer across the charge transfer fitting while avoiding substantial bulk fluid transfer across the charge transfer fitting. Advantages of the present invention have been demonstrated as effective in providing high sensitivity and efficient analyses.

  8. Capillary electrophoresis electrospray ionization mass spectrometry interface

    DOEpatents

    Smith, Richard D.; Severs, Joanne C.

    1999-01-01

    The present invention is an interface between a capillary electrophoresis separation capillary end and an electrospray ionization mass spectrometry emitter capillary end, for transporting an anolyte sample from a capillary electrophoresis separation capillary to a electrospray ionization mass spectrometry emitter capillary. The interface of the present invention has: (a) a charge transfer fitting enclosing both of the capillary electrophoresis capillary end and the electrospray ionization mass spectrometry emitter capillary end; (b) a reservoir containing an electrolyte surrounding the charge transfer fitting; and (c) an electrode immersed into the electrolyte, the electrode closing a capillary electrophoresis circuit and providing charge transfer across the charge transfer fitting while avoiding substantial bulk fluid transfer across the charge transfer fitting. Advantages of the present invention have been demonstrated as effective in providing high sensitivity and efficient analyses.

  9. Transition of Iodine Analysis to Accelerator Mass Spectrometry

    SciTech Connect

    Watrous, Matthew George; Adamic, Mary Louise; Olson, John Eric; Baeck, D. L.; Fox, R. V.; Hahn, P. A.; Jenson, D. D.; Lister, T. E.

    2015-09-01

    The goal of the project, New Paradigms for Isotope Ratio Mass Spectrometry: Raising the Scientific Profile and Improved Performance for Accelerator Mass Spectrometry (AMS) and Thermal Ionization Mass Spectrometry (TIMS), is to ensure that the ongoing isotope ratio determination capability within the U.S. Department of Energy complex is the world’s best for application to nonproliferation. This report spells out the progress of Task 4, Transition of TIMS to AMS for Iodine Analysis, of the larger project. The subtasks under Task 4 and the accomplishments throughout the three year project life cycle are presented in this report. Progress was made in optimization of chemical extraction, determination of a detection limit for 127Iodine, production of standard materials for AMS analysis quality assurance, facilitation of knowledge exchange with respect to analyzing iodine on an AMS, cross comparison with a world-leading AMS laboratory, supercritical fluid extraction of iodine for AMS analysis and electrodeposition of seawater as a direct method of preparation for iodine analysis by AMS--all with the goal of minimizing the time required to stand up an AMS capability for iodine analysis of exposed air filters at INL. An effective extraction method has been developed and demonstrated for iodine analysis of exposed air filters. Innovative techniques to accomplish the cathode preparation for AMS analysis were developed and demonstrated and published. The known gap of a lack of available materials for reference standards in the analysis of iodine by AMS was filled by the preparation of homogenous materials that were calibrated against NIST materials. A minimum limit on the amount of abundant isotope in a sample was determined for AMS analysis. The knowledge exchange occurred with fantastic success. Scientists engaged the international AMS community at conferences, as well as in their laboratories for collaborative work. The supercritical fluid extraction work has positive

  10. Ultraviolet femtosecond laser ionization mass spectrometry.

    PubMed

    Imasaka, Totaro

    2008-01-01

    For this study, multiphoton ionization/mass spectrometry using an ultraviolet (UV) femtosecond laser was employed for the trace analysis of organic compounds. Some of the molecules, such as dioxins, contain several chlorine atoms and have short excited-state lifetimes due to a "heavy atom" effect. A UV femtosecond laser is, then, useful for efficient resonance excitation and subsequent ionization. A technique of multiphoton ionization using an extremely short laser pulse (e.g., <10 fs), referred to as "impulsive ionization," may have a potential for use in fragmentation-free ionization, thus providing information on molecular weight in mass spectrometry. PMID:18302290

  11. Analysis of Electroblotted Proteins by Mass Spectrometry

    PubMed Central

    Luque-Garcia, Jose L.; Neubert, Thomas A.

    2015-01-01

    Summary Identification of proteins by mass spectrometry is crucial for better understanding of many biological, biochemical, and biomedical processes. Here we describe two methods for the identification of electroblotted proteins by on-membrane digestion prior to analysis by mass spectrometry. These on-membrane methods take approximately half the time of in-gel digestion and provide better digestion efficiency, due to the better accessibility of the protease to the proteins adsorbed onto the nitrocellulose, and better protein sequence coverage, especially for membrane proteins where large and hydrophobic peptides are commonly present. PMID:26139272

  12. Mass spectrometry for pectin structure analysis.

    PubMed

    Ralet, Marie-Christine; Lerouge, Patrice; Quéméner, Bernard

    2009-09-28

    Pectin are extremely complex biopolymers made up of different structural domains. Enzymatic degradation followed by purification and structural analysis of the degradation products proved to be efficient tools for the understanding of pectin fine structure, including covalent interactions between pectic structural domains or with other cell wall polysaccharides. Due to its high sensitivity, high throughput and capacity to analyze mixtures, mass spectrometry has gained more and more importance as a tool for oligosaccharides structural characterization in the past 10 years. This review will focus on the combined use of mass spectrometry and enzymatic digestion for pectins structural characterization. PMID:19058795

  13. Development of Gas Chromatographic Mass Spectrometry.

    PubMed

    Hites, Ronald A

    2016-07-19

    Gas chromatographic mass spectrometry is now widely used for the quantitation and identification of organic compounds in almost any imaginable sample. These applications include the measurement of chlorinated dioxins in soil samples, the identification of illicit drugs in human blood, and the quantitation of accelerants in arson investigations, to name just a few. How did GC/MS get so popular? It turns out that it required parallel developments in mass spectrometry, gas chromatography, and computing and that no one person "invented" the technique. This Perspective traces this history from the 1950s until today. PMID:27384908

  14. Fast Atom Bombardment Mass Spectrometry.

    ERIC Educational Resources Information Center

    Rinehart, Kenneth L., Jr.

    1982-01-01

    Discusses reactions and characteristics of fast atom bombardment (FAB) mass spectroscopy in which samples are ionized in a condensed state by bombardment with xenon or argon atoms, yielding positive/negative secondary ions. Includes applications of FAB to structural problems and considers future developments using the technique. (Author/JN)

  15. Targeted quantitation of proteins by mass spectrometry.

    PubMed

    Liebler, Daniel C; Zimmerman, Lisa J

    2013-06-01

    Quantitative measurement of proteins is one of the most fundamental analytical tasks in a biochemistry laboratory, but widely used immunochemical methods often have limited specificity and high measurement variation. In this review, we discuss applications of multiple-reaction monitoring (MRM) mass spectrometry, which allows sensitive, precise quantitative analyses of peptides and the proteins from which they are derived. Systematic development of MRM assays is permitted by databases of peptide mass spectra and sequences, software tools for analysis design and data analysis, and rapid evolution of tandem mass spectrometer technology. Key advantages of MRM assays are the ability to target specific peptide sequences, including variants and modified forms, and the capacity for multiplexing that allows analysis of dozens to hundreds of peptides. Different quantitative standardization methods provide options that balance precision, sensitivity, and assay cost. Targeted protein quantitation by MRM and related mass spectrometry methods can advance biochemistry by transforming approaches to protein measurement. PMID:23517332

  16. Mass spectrometry in the home and garden.

    PubMed

    Pulliam, Christopher J; Bain, Ryan M; Wiley, Joshua S; Ouyang, Zheng; Cooks, R Graham

    2015-02-01

    Identification of active components in a variety of chemical products used directly by consumers is described at both trace and bulk levels using mass spectrometry. The combination of external ambient ionization with a portable mass spectrometer capable of tandem mass spectrometry provides high chemical specificity and sensitivity as well as allowing on-site monitoring. These experiments were done using a custom-built portable ion trap mass spectrometer in combination with the ambient ionization methods of paper spray, leaf spray, and low temperature plasma ionization. Bactericides, garden chemicals, air fresheners, and other products were examined. Herbicide applied to suburban lawns was detected in situ on single leaves 5 d after application. PMID:25510934

  17. Continuous Simultaneous Detection in Mass Spectrometry

    SciTech Connect

    Schilling, G. D.; Andrade, Francisco J.; Barnes IV., James H.; Sperline, Roger P.; Denton, M. Bonner; Barinaga, Charles J.; Koppenaal, David W.; Hieftje, Gary M.

    2007-10-15

    In mass spectrometry, several advantages can be derived when multiple mass-to-charge values are detected simultaneously. One such advantage is an improved duty cycle, which leads to superior limits of detection, better precision, shorter analysis times, and reduced sample sizes. A second advantage is the ability to reduce correlated noise by taking the ratio of two or more simultaneously collected signals, enabling greatly enhanced isotope ratio data. A final advantage is the elimination of spectral skew, leading to more accurate transient signal analysis. Here, these advantages are demonstrated by means of a novel Faraday-strip array detector coupled to a Mattauch-Herzog mass spectrograph. The same system is used to monitor elemental fractionation phenomena in laser ablation inductively coupled plasma mass spectrometry.

  18. Atmospheric pressure femtosecond laser imaging mass spectrometry

    NASA Astrophysics Data System (ADS)

    Coello, Yves; Gunaratne, Tissa C.; Dantus, Marcos

    2009-02-01

    We present a novel imaging mass spectrometry technique that uses femtosecond laser pulses to directly ionize the sample. The method offers significant advantages over current techniques by eliminating the need of a laser-absorbing sample matrix, being suitable for atmospheric pressure sampling, and by providing 10μm resolution, as demonstrated here with a chemical image of vegetable cell walls.

  19. Accelerator mass spectrometry with heavy ions

    NASA Astrophysics Data System (ADS)

    Haberstock, Günther; Heinzl, Johann; Korschinek, Gunther; Morinaga, Haruhiko; Nolte, Eckehart; Ratzinger, Ulrich; Kato, Kazuo; Wolf, Manfred

    1986-11-01

    Accelerator mass spectrometry measurements with fully stripped 36Cl ions have been performed at the Munich accelerator laboratory in order to date groundwaters and palaeontological samples, to study anthropogenic 36Cl produced through nuclear tests and to determine the fast neutron flux of the Hiroshima A-bomb.

  20. Nanostructure-initiator mass spectrometry biometrics

    DOEpatents

    Leclerc, Marion; Bowen, Benjamin; Northen, Trent

    2015-09-08

    Several embodiments described herein are drawn to methods of identifying an analyte on a subject's skin, methods of generating a fingerprint, methods of determining a physiological change in a subject, methods of diagnosing health status of a subject, and assay systems for detecting an analyte and generating a fingerprint, by nanostructure-initiator mass spectrometry (NIMS).

  1. Pyrolysis Mass Spectrometry of Complex Organic Materials.

    ERIC Educational Resources Information Center

    Meuzelaar, Henk L. C.; And Others

    1984-01-01

    Illustrates the state of the art in pyrolysis mass spectrometry techniques through applications in: (1) structural determination and quality control of synthetic polymers; (2) quantitative analysis of polymer mixtures; (3) classification and structural characterization of fossil organic matter; and (4) nonsupervised numerical extraction of…

  2. Introduction to mass spectrometry-based proteomics.

    PubMed

    Matthiesen, Rune; Bunkenborg, Jakob

    2013-01-01

    Mass spectrometry has been widely applied to study biomolecules and one rapidly developing field is the global analysis of proteins, proteomics. Understanding and handling mass spectrometry data is a multifaceted task that requires many decisions to be made to get the most comprehensive information from an experiment. Later chapters in this book deal in-depth with various aspects of the process and how different tools can be applied to the many analytical challenges. This introductory chapter is intended as a basic introduction to mass spectrometry (MS)-based proteomics to set the scene for newcomers and give pointers to reference material. There are many applications of mass spectrometry in proteomics and each application is associated with some analytical choices, instrumental limitations and data processing steps that depend on the aim of the study and means of conducting it. Different aspects of the proteome can be explored by choosing the right combination of sample preparation, MS instrumentation and data processing. This chapter gives an outline for some of these commonly used setups and some of the key concepts, many of which are explored in greater depth in later chapters. PMID:23666720

  3. Optimization Of A Mass Spectrometry Process

    SciTech Connect

    Lopes, Jose; Alegria, F. Correa; Redondo, Luis; Barradas, N. P.; Alves, E.; Rocha, Jorge

    2011-06-01

    In this paper we present and discuss a system developed in order to optimize the mass spectrometry process of an ion implanter. The system uses a PC to control and display the mass spectrum. The operator interacts with the I/O board, that interfaces with the computer and the ion implanter by a LabVIEW code. Experimental results are shown and the capabilities of the system are discussed.

  4. Mass transfer in countercurrent packed columns: Application to supercritical CO[sub 2] extraction of terpenes

    SciTech Connect

    Simoes, P.C.; Matos, H.A.; Carmelo, P.J.; Gomes de Azevedo, E.; Nunes da Ponte, M. . Faculdade de Ciencias e Tecnologia)

    1995-02-01

    Supercritical fluid extraction (SFE) is an alternative separation method to more conventional processes such as liquid extraction and distillation. However, up to now, few works have been devoted to the investigation of the efficiency of countercurrent packed columns under supercritical conditions from a mass transfer point of view. Mass transfer in a countercurrent column, filled with structured gauze packing, was measured for the separation of a mixture of terpenes (d-limonene/1,8-cineole) by supercritical carbon dioxide, at 313 and 318 K and pressures up to 9 MPa. The extraction efficiency was determined in terms of the overall mass transfer coefficient. Operating lines for this process had an appreciable curvature due to a high miscibility of the two contacting phases. The real slope of these lines had to be estimated. Available mass transfer models for packed columns predicted efficiencies diverging to a great extent from the experimental results.

  5. Application of mass spectrometry for metabolite identification.

    PubMed

    Ma, Shuguang; Chowdhury, Swapan K; Alton, Kevin B

    2006-06-01

    Metabolism studies play a pivotal role in drug discovery and development. Characterization of metabolic "hot-spots" as well as reactive and pharmacologically active metabolites is critical to designing new drug candidates with improved metabolic stability, toxicological profile and efficacy. Metabolite identification in the preclinical species used for safety evaluation is required in order to determine whether human metabolites have been adequately tested during non-clinical safety assessment. From an instrumental standpoint, high performance liquid chromatography (HPLC) coupled with mass spectrometry (MS) dominates all analytical tools used for metabolite identification. The general strategies employed for metabolite identification in both drug discovery and drug development settings together with sample preparation techniques are reviewed herein. These include a discussion of the various ionization methods, mass analyzers, and tandem mass spectrometry (MS/MS) techniques that are used for structural characterization in a modern drug metabolism laboratory. Mass spectrometry-based techniques, such as stable isotope labeling, on-line H/D exchange, accurate mass measurement to enhance metabolite identification and recent improvements in data acquisition and processing for accelerating metabolite identification are also described. Rounding out this review, we offer additional thoughts about the potential of alternative and less frequently used techniques such as LC-NMR/MS, CRIMS and ICPMS. PMID:16787159

  6. Space Applications of Mass Spectrometry. Chapter 31

    NASA Technical Reports Server (NTRS)

    Hoffman, John H.; Griffin, Timothy P.; Limero, Thomas; Arkin, C. Richard

    2010-01-01

    Mass spectrometers have been involved in essentially all aspects of space exploration. This chapter outlines some of these many uses. Mass spectrometers have not only helped to expand our knowledge and understanding of the world and solar system around us, they have helped to put man safely in space and expand our frontier. Mass spectrometry continues to prove to be a very reliable, robust, and flexible analytical instrument, ensuring that its use will continue to help aid our investigation of the universe and this small planet that we call home.

  7. The ultrasonic-enhanced factor of mass-transfer coefficient in the supercritical carbon dioxide extraction

    NASA Astrophysics Data System (ADS)

    Luo, Benyi; Lu, Yigang

    2008-10-01

    Based on several hypotheses about the process of supercritical carbon dioxide extraction, the onflow around the solute granule is figured out by the Navier-Stocks equation. In combination with the Higbie’s solute infiltration model, the link between the mass-transfer coefficient and the velocity of flow is found. The mass-transfer coefficient with the ultrasonical effect is compared with that without the ultrasonical effect, and then a new parameter named the ultrasonic-enhanced factor of mass-transfer coefficient is brought forward, which describes the mathematical model of the supercritical carbon dioxide extraction process enhanced by ultrasonic. The model gives out the relationships among the ultrasonical power, the ultrasonical frequency, the radius of solute granule and the ultrasonic-enhanced factor of mass-transfer coefficient. The results calculated by this model fit well with the experimental data, including the extraction of Coix Lacryma-jobi Seed Oil (CLSO) and Coix Lacryma-jobi Seed Ester (CLSE) from coix seeds and the extraction of Eicosapentaenoic Acid (EPA) and Docosahexaenoic Acid (DHA) from the alga by means of the ultrasonic-enhanced supercritical carbon dioxide extraction (USFE) and the supercritical carbon dioxide extraction (SFE) respectively. This proves the rationality of the ultrasonic-enhanced factor model. The model provides a theoretical basis for the application of ultrasonic-enhanced supercritical fluid extraction technique.

  8. Evolution of Orbitrap Mass Spectrometry Instrumentation

    NASA Astrophysics Data System (ADS)

    Eliuk, Shannon; Makarov, Alexander

    2015-07-01

    We discuss the evolution of OrbitrapTM mass spectrometry (MS) from its birth in the late 1990s to its current role as one of the most prominent techniques for MS. The Orbitrap mass analyzer is the first high-performance mass analyzer that employs trapping of ions in electrostatic fields. Tight integration with the ion injection process enables the high-resolution, mass accuracy, and sensitivity that have become essential for addressing analytical needs in numerous areas of research, as well as in routine analysis. We examine three major families of instruments (related to the LTQ Orbitrap, Q Exactive, and Orbitrap Fusion mass spectrometers) in the context of their historical development over the past ten eventful years. We discuss as well future trends and perspectives of Orbitrap MS. We illustrate the compelling potential of Orbitrap-based mass spectrometers as (ultra) high-resolution platforms, not only for high-end proteomic applications, but also for routine targeted analysis.

  9. Nuclear applications of inorganic mass spectrometry.

    PubMed

    De Laeter, John

    2010-01-01

    There are several basic characteristics of mass spectrometry that are not always fully appreciated by the science community. These characteristics include the distinction between relative and absolute isotope abundances, and the influence of isotope fractionation on the accuracy of isotopic measurements. These characteristics can be illustrated in the field of nuclear physics with reference to the measurement of nuclear parameters, which involve the use of enriched isotopes, and to test models of s-, r-, and p-process nucleosynthesis. The power of isotope-dilution mass spectrometry (IDMS) to measure trace elements in primitive meteorites to produce accurate Solar System abundances has been essential to the development of nuclear astrophysics. The variety of mass spectrometric instrumentation used to measure the isotopic composition of elements has sometimes been accompanied by a lack of implementation of basic mass spectrometric protocols which are applicable to all instruments. These metrological protocols are especially important in atomic weight determinations, but must also be carefully observed in cases where the anomalies might be very small, such as in studies of the daughter products of extinct radionuclides to decipher events in the early history of the Solar System. There are occasions in which misleading conclusions have been drawn from isotopic data derived from mass spectrometers where such protocols have been ignored. It is important to choose the mass spectrometer instrument most appropriate to the proposed experiment. The importance of the integrative nature of mass spectrometric measurements has been demonstrated by experiments in which long, double beta decay and geochronological decay half-lives have been measured as an alternative to costly radioactive-counting experiments. This characteristic is also illustrated in the measurement of spontaneous fission yields, which have accumulated over long periods of time. Mass spectrometry is also a

  10. Linking Mass Spectrometry with Toxicology for Emerging Water Contaminants

    EPA Science Inventory

    This overview presentation will discuss the benefits of combining mass spectrometry with toxicology. These benefits will be described for 3 main areas: (1) Toxicity assays used to test new environmental contaminants previously identified using mass spectrometry, such that furth...

  11. Laser-desorption mass spectrometry/mass spectrometry and the mechanism of desorption ionization

    SciTech Connect

    Zakett, D.; Schoen, A.E.; Cooks, R.G.; Hemberger, P.H.

    1981-03-11

    This paper reports sucrose mass spectra obtained by combining laser desorption with mass spectrometry/mass spectrometry. Remarkable similarities in fragmentation behavior with secondary ion mass spectra (SIMS) provide evidence for mechanistic similarities between SIMS and laser desorption (LD). Attachment of alkali metals to organic molecules (cationization) is a common feature of desorption ionization. This process also occurs during laser desorption of involatile compounds which further indicates the existence of underlying similarities between LD and SIMS. Steady ion currents (several thousand ions per laser pulse) of cationized sucrose are obtained for relatively long periods (minutes).

  12. High resolution laser mass spectrometry bioimaging.

    PubMed

    Murray, Kermit K; Seneviratne, Chinthaka A; Ghorai, Suman

    2016-07-15

    Mass spectrometry imaging (MSI) was introduced more than five decades ago with secondary ion mass spectrometry (SIMS) and a decade later with laser desorption/ionization (LDI) mass spectrometry (MS). Large biomolecule imaging by matrix-assisted laser desorption/ionization (MALDI) was developed in the 1990s and ambient laser MS a decade ago. Although SIMS has been capable of imaging with a moderate mass range at sub-micrometer lateral resolution from its inception, laser MS requires additional effort to achieve a lateral resolution of 10μm or below which is required to image at the size scale of single mammalian cells. This review covers untargeted large biomolecule MSI using lasers for desorption/ionization or laser desorption and post-ionization. These methods include laser microprobe (LDI) MSI, MALDI MSI, laser ambient and atmospheric pressure MSI, and near-field laser ablation MS. Novel approaches to improving lateral resolution are discussed, including oversampling, beam shaping, transmission geometry, reflective and through-hole objectives, microscope mode, and near-field optics. PMID:26972785

  13. Mass Spectrometry Imaging under Ambient Conditions

    PubMed Central

    Wu, Chunping; Dill, Allison L.; Eberlin, Livia S.; Cooks, R. Graham; Ifa, Demian R.

    2012-01-01

    Mass spectrometry imaging (MSI) has emerged as an important tool in the last decade and it is beginning to show potential to provide new information in many fields owing to its unique ability to acquire molecularly specific images and to provide multiplexed information, without the need for labeling or staining. In MSI, the chemical identity of molecules present on a surface is investigated as a function of spatial distribution. In addition to now standard methods involving MSI in vacuum, recently developed ambient ionization techniques allow MSI to be performed under atmospheric pressure on untreated samples outside the mass spectrometer. Here we review recent developments and applications of MSI emphasizing the ambient ionization techniques of desorption electrospray ionization (DESI), laser ablation electrospray ionization (LAESI), probe electrospray ionization (PESI), desorption atmospheric pressure photoionization (DAPPI), femtosecond laser desorption ionization (fs-LDI), laser electrospray mass spectrometry (LEMS), infrared laser ablation metastable-induced chemical ionization (IR-LAMICI), liquid microjunction surface sampling probe mass spectrometry (LMJ-SSP MS), nanospray desorption electrospray ionization (nano-DESI), and plasma sources such as the low temperature plasma (LTP) probe and laser ablation coupled to flowing atmospheric-pressure afterglow (LA-FAPA). Included are discussions of some of the features of ambient MSI including the ability to implement chemical reactions with the goal of providing high abundance ions characteristic of specific compounds of interest and the use of tandem mass spectrometry to either map the distribution of targeted molecules with high specificity or to provide additional MS information in the structural identification of compounds. We also describe the role of bioinformatics in acquiring and interpreting the chemical and spatial information obtained through MSI, especially in biological applications for tissue

  14. Choosing between high-resolution mass spectrometry and mass spectrometry/mass spectrometry: Environmental applications

    SciTech Connect

    Charles, M.J. ); Tondeur, Y. )

    1990-12-01

    Selectivity in environmental analyses requires the use of fractionation techniques and HRMS or MS/MS to eliminate specific and nonspecific interferences. In the analysis of TCDDs and TCDFs, HRMS is the method of choice when specific interferences arising from compounds with molecular or fragment ions can be separated from TCDD and TCDF ions at a resolving power of 10,000. In cases where HRMS does not provide adequate selectivity at this resolving power, MS/MS is needed. Analyses on a pulp and paper effluent extract show that MS/MS was able to substantially eliminate interferences due to the presence of methyl and ethyl tetrachlorinated dibenzofurans that were not removed by HRMS at resolving powers of 10,000 and 18,000. Nonspecific interferences may also be present due to coelution of compounds that cause changes in the response of the mass spectrometer and are best eliminated by fractionation techniques or by altering conditions of analyses.

  15. Laser-Cooling-Assisted Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Schneider, Christian; Schowalter, Steven J.; Chen, Kuang; Sullivan, Scott T.; Hudson, Eric R.

    2014-09-01

    Mass spectrometry is used in a wide range of scientific disciplines including proteomics, pharmaceutics, forensics, and fundamental physics and chemistry. Given this ubiquity, there is a worldwide effort to improve the efficiency and resolution of mass spectrometers. However, the performance of all techniques is ultimately limited by the initial phase-space distribution of the molecules being analyzed. Here, we dramatically reduce the width of this initial phase-space distribution by sympathetically cooling the input molecules with laser-cooled, cotrapped atomic ions, improving both the mass resolution and detection efficiency of a time-of-flight mass spectrometer by over an order of magnitude. Detailed molecular-dynamics simulations verify the technique and aid with evaluating its effectiveness. This technique appears to be applicable to other types of mass spectrometers.

  16. Mass spectrometry in Chronic Kidney Disease research

    PubMed Central

    Merchant, Michael L.

    2010-01-01

    Proteomics has evolved into an invaluable tool for biomedical research and for research on renal diseases. A central player in the proteomic revolution is the mass spectrometer and its application to analyze biological samples. Our need to understand both the identity of proteins and their abundance has led to improvements in mass spectrometers and their ability to analyze complex tryptic peptide mixtures with high sensitivity and high mass accuracy in a high throughput fashion (such as the LTQ-Orbitrap). It should not be surprising that this occurred coincident with dramatic improvements in our understanding chronic kidney disease (CKD), the mechanisms through which CKD progresses and the development of candidate CKD biomarkers. This review attempts to present a basic framework for the operational components of mass spectrometers, basic insight into how they are used in renal research and a discussion of CKD research that was driven by mass spectrometry. PMID:21044768

  17. Storage-Ring Mass Spectrometry in Japan

    NASA Astrophysics Data System (ADS)

    Suzaki, Fumi; Yamaguchi, Takayuki

    Atomic masses are a fundamental ground-state property of nuclei, reflecting a wide variety of structures and dynamics among nucleons. High-precision mass values of short-lived, in particular neutron-rich, nuclei are a key issue toward full understanding of astrophysical nucleosynthesis, as well as nuclear shell evolution far from stability. Beyond the precision mass measurements performed at worldwide ion-trap facilities, a new method of storage-ring mass spectrometry is now being developed at the RIKEN RI Beam Factory in Japan. Combined with the highest intensities of intermediate-energy radioactive ion beams currently available through in-flight separation of uranium fission products, the present method will enable us to measure the masses of extremely neutron-rich, rare species located on the r-process pathway, with a tiny yield (as low as ~1 counts/day).

  18. Biological particle analysis by mass spectrometry

    NASA Technical Reports Server (NTRS)

    Vilker, V. L.; Platz, R. M.

    1983-01-01

    An instrument that analyzes the chemical composition of biological particles in aerosol or hydrosol form was developed. Efforts were directed toward the acquisition of mass spectra from aerosols of biomolecules and bacteria. The filament ion source was installed on the particle analysis by mass spectrometry system. Modifications of the vacuum system improved the sensitivity of the mass spectrometer. After the modifications were incorporated, detailed mass spectra of simple compounds from the three major classes of biomolecules, proteins, nucleic acids, and carbohydrates were obtained. A method of generating bacterial aerosols was developed. The aerosols generated were collected and examined in the scanning electron microscope to insure that the bacteria delivered to the mass spectrometer were intact and free from debris.

  19. Antibodies as means for selective mass spectrometry.

    PubMed

    Boström, Tove; Takanen, Jenny Ottosson; Hober, Sophia

    2016-05-15

    For protein analysis of biological samples, two major strategies are used today; mass spectrometry (MS) and antibody-based methods. Each strategy offers advantages and drawbacks. However, combining the two using an immunoenrichment step with MS analysis brings together the benefits of each method resulting in increased sensitivity, faster analysis and possibility of higher degrees of multiplexing. The immunoenrichment can be performed either on protein or peptide level and quantification standards can be added in order to enable determination of the absolute protein concentration in the sample. The combination of immunoenrichment and MS holds great promise for the future in both proteomics and clinical diagnostics. This review describes different setups of immunoenrichment coupled to mass spectrometry and how these can be utilized in various applications. PMID:26565067

  20. Mass spectrometry imaging for biomedical applications

    PubMed Central

    Liu, Jiangjiang; Ouyang, Zheng

    2013-01-01

    The development of mass spectrometry imaging technologies is of significant current research interest. Mass spectrometry potentially is capable of providing highly specific information about the distribution of chemical compounds on tissues at highly sensitive levels. The required in-situ analysis for the tissue imaging forced MS analysis being performed off the traditional conditions optimized in pharmaceutical applications with intense sample preparation. This critical review seeks to present an overview of the current status of the MS imaging with different sampling ionization methods and to discuss the 3D imaging and quantitative imaging capabilities needed to be further developed, the importance of the multi-modal imaging, and a balance between the pursuit of the high imaging resolution and the practical application of MS imaging in biomedicine. PMID:23539099

  1. Spatial neuroproteomics using imaging mass spectrometry.

    PubMed

    Hanrieder, Jörg; Malmberg, Per; Ewing, Andrew G

    2015-07-01

    The nervous system constitutes arguably the most complicated and least understood cellular network in the human body. This consequently manifests itself in the fact that the molecular bases of neurodegenerative diseases remain unknown. The limited understanding of neurobiological mechanisms relates directly to the lack of appropriate bioanalytical technologies that allow highly resolved, sensitive, specific and comprehensive molecular imaging in complex biological matrices. Imaging mass spectrometry (IMS) is an emerging technique for molecular imaging. The technique is characterized by its high chemical specificity allowing comprehensive, spatial protein and peptide profiling in situ. Imaging MS represents therefore a powerful approach for investigation of spatio-temporal protein and peptide regulations in CNS derived tissue and cells. This review aims to provide a concise overview of major developments and applications concerning imaging mass spectrometry based protein and peptide profiling in neurobiological and biomedical research. This article is part of a Special Issue entitled: Neuroproteomics: Applications in Neuroscience and Neurology. PMID:25582083

  2. Biomarker Signature Discovery from Mass Spectrometry Data.

    PubMed

    Kong, Ao; Gupta, Chinmaya; Ferrari, Mauro; Agostini, Marco; Bedin, Chiara; Bouamrani, Ali; Tasciotti, Ennio; Azencott, Robert

    2014-01-01

    Mass spectrometry based high throughput proteomics are used for protein analysis and clinical diagnosis. Many machine learning methods have been used to construct classifiers based on mass spectrometry data, for discrimination between cancer stages. However, the classifiers generated by machine learning such as SVM techniques typically lack biological interpretability. We present an innovative technique for automated discovery of signatures optimized to characterize various cancer stages. We validate our signature discovery algorithm on one new colorectal cancer MALDI-TOF data set, and two well-known ovarian cancer SELDI-TOF data sets. In all of these cases, our signature based classifiers performed either better or at least as well as four benchmark machine learning algorithms including SVM and KNN. Moreover, our optimized signatures automatically select smaller sets of key biomarkers than the black-boxes generated by machine learning, and are much easier to interpret. PMID:26356346

  3. High-sensitivity mass spectrometry with a tandem accelerator

    SciTech Connect

    Henning, W.

    1983-01-01

    The characteristic features of accelerator mass spectrometry are discussed. A short overview is given of the current status of mass spectrometry with high-energy (MeV/nucleon) heavy-ion accelerators. Emphasis is placed on studies with tandem accelerators and on future mass spectrometry of heavier isotopes with the new generation of higher-voltage tandems.

  4. A Mass Spectrometry Proteomics Data Management Platform*

    PubMed Central

    Sharma, Vagisha; Eng, Jimmy K.; MacCoss, Michael J.; Riffle, Michael

    2012-01-01

    Mass spectrometry-based proteomics is increasingly being used in biomedical research. These experiments typically generate a large volume of highly complex data, and the volume and complexity are only increasing with time. There exist many software pipelines for analyzing these data (each typically with its own file formats), and as technology improves, these file formats change and new formats are developed. Files produced from these myriad software programs may accumulate on hard disks or tape drives over time, with older files being rendered progressively more obsolete and unusable with each successive technical advancement and data format change. Although initiatives exist to standardize the file formats used in proteomics, they do not address the core failings of a file-based data management system: (1) files are typically poorly annotated experimentally, (2) files are “organically” distributed across laboratory file systems in an ad hoc manner, (3) files formats become obsolete, and (4) searching the data and comparing and contrasting results across separate experiments is very inefficient (if possible at all). Here we present a relational database architecture and accompanying web application dubbed Mass Spectrometry Data Platform that is designed to address the failings of the file-based mass spectrometry data management approach. The database is designed such that the output of disparate software pipelines may be imported into a core set of unified tables, with these core tables being extended to support data generated by specific pipelines. Because the data are unified, they may be queried, viewed, and compared across multiple experiments using a common web interface. Mass Spectrometry Data Platform is open source and freely available at http://code.google.com/p/msdapl/. PMID:22611296

  5. Monolithic multinozzle emitters for nanoelectrospray mass spectrometry

    DOEpatents

    Wang, Daojing; Yang, Peidong; Kim, Woong; Fan, Rong

    2011-09-20

    Novel and significantly simplified procedures for fabrication of fully integrated nanoelectrospray emitters have been described. For nanofabricated monolithic multinozzle emitters (NM.sup.2 emitters), a bottom up approach using silicon nanowires on a silicon sliver is used. For microfabricated monolithic multinozzle emitters (M.sup.3 emitters), a top down approach using MEMS techniques on silicon wafers is used. The emitters have performance comparable to that of commercially-available silica capillary emitters for nanoelectrospray mass spectrometry.

  6. Mass Spectrometry in Plant-omics.

    PubMed

    Gemperline, Erin; Keller, Caitlin; Li, Lingjun

    2016-04-01

    Plant-omics is rapidly becoming an important field of study in the scientific community due to the urgent need to address many of the most important questions facing humanity today with regard to agriculture, medicine, biofuels, environmental decontamination, ecological sustainability, etc. High-performance mass spectrometry is a dominant tool for interrogating the metabolomes, peptidomes, and proteomes of a diversity of plant species under various conditions, revealing key insights into the functions and mechanisms of plant biochemistry. PMID:26889688

  7. Dissecting SUMO Dynamics by Mass Spectrometry.

    PubMed

    Drabikowski, Krzysztof; Dadlez, Michał

    2016-01-01

    Protein modification by SUMO proteins is one of the key posttranslational modifications in eukaryotes. Here, we describe a workflow to analyze SUMO dynamics in response to different stimuli, purify SUMO conjugates, and analyze the changes in SUMOylation level in organisms, tissues, or cell culture. We present a protocol for lysis in denaturing conditions that is compatible with downstream IMAC and antibody affinity purification, followed by mass spectrometry and data analysis. PMID:27613044

  8. Advances in Mass Spectrometry for Lipidomics

    NASA Astrophysics Data System (ADS)

    Blanksby, Stephen J.; Mitchell, Todd W.

    2010-07-01

    Recent expansion in research in the field of lipidomics has been driven by the development of new mass spectrometric tools and protocols for the identification and quantification of molecular lipids in complex matrices. Although there are similarities between the field of lipidomics and the allied field of mass spectrometry (e.g., proteomics), lipids present some unique advantages and challenges for mass spectrometric analysis. The application of electrospray ionization to crude lipid extracts without prior fractionation—the so-called shotgun approach—is one such example, as it has perhaps been more successfully applied in lipidomics than in any other discipline. Conversely, the diverse molecular structure of lipids means that collision-induced dissociation alone may be limited in providing unique descriptions of complex lipid structures, and the development of additional, complementary tools for ion activation and analysis is required to overcome these challenges. In this article, we discuss the state of the art in lipid mass spectrometry and highlight several areas in which current approaches are deficient and further innovation is required.

  9. Mass spectrometry imaging: Towards a lipid microscope?

    PubMed

    Touboul, David; Brunelle, Alain; Laprévote, Olivier

    2011-01-01

    Biological imaging techniques are the most efficient way to locally measure the variation of different parameters on tissue sections. These analyses are gaining increasing interest since 20 years and allow observing extremely complex biological phenomena at lower and lower time and resolution scale. Nevertheless, most of them only target very few compounds of interest, which are chosen a priori, due to their low resolution power and sensitivity. New chemical imaging technique has to be introduced in order to overcome these limitations, leading to more informative and sensitive analyses for biologists and physicians. Two major mass spectrometry methods can be efficiently used to generate the distribution of biological compounds over a tissue section. Matrix-Assisted Laser Desorption/Ionisation-Mass Spectrometry (MALDI-MS) needs the co-crystallization of the sample with a matrix before to be irradiated by a laser, whereas the analyte is directly desorbed by a primary ion bombardment for Secondary Ion Mass Spectrometry (SIMS) experiments. In both cases, energy used for desorption/ionization is locally deposited -some tens of microns for the laser and some hundreds of nanometers for the ion beam- meaning that small areas over the surface sample can be separately analyzed. Step by step analysis allows spectrum acquisitions over the tissue sections and the data are treated by modern informatics software in order to create ion density maps, i.e., the intensity plot of one specific ion versus the (x,y) position. Main advantages of SIMS and MALDI compared to other chemical imaging techniques lie in the simultaneous acquisition of a large number of biological compounds in mixture with an excellent sensitivity obtained by Time-of-Flight (ToF) mass analyzer. Moreover, data treatment is done a posteriori, due to the fact that no compound is selectively marked, and let us access to the localization of different lipid classes in only one complete acquisition. PMID:20570708

  10. Uncoiling collagen: a multidimensional mass spectrometry study.

    PubMed

    Simon, H J; van Agthoven, M A; Lam, P Y; Floris, F; Chiron, L; Delsuc, M-A; Rolando, C; Barrow, M P; O'Connor, P B

    2016-01-01

    Mass spectrometry can be used to determine structural information about ions by activating precursors and analysing the resulting series of fragments. Two-dimensional Fourier transform ion cyclotron resonance mass spectrometry (2D FT-ICR MS) is a technique that correlates the mass-to-charge (m/z) ratio of fragment and precursor ions in a single spectrum. 2D FT-ICR MS records the fragmentation of all ions in a sample without the need for isolation. To analyse specific precursors, horizontal cross-sections of the spectrum (fragment ion scans) are taken, providing an alternative to conventional tandem mass spectrometry (MS/MS) experiments. In this work, 2D FT-ICR MS has been used to study the tryptic digest of type I collagen, a large protein. Fragment ion scans have been extracted from the 2D FT-ICR MS spectrum for precursor m/z ratios: 951.81, 850.41, 634.34, and 659.34, and 2D FT-ICR MS spectra are compared with a set of 1D MS/MS spectra using different fragmentation methods. The results show that two-dimensional mass spectrometry excells at MS/MS of complex mixtures, simplifying spectra by eliminating contaminant peaks, and aiding the identification of species in the sample. Currently, with desktop computers, 2D FT-ICR MS is limited by data processing power, a limitation which should be alleviated using cluster parallel computing. In order to explore 2D FT-ICR MS for collagen, with reasonable computing time, the resolution in the fragment ion dimension is limited to 256k data points (compared to 4M data points in 1D MS/MS spectra), but the vertical precursor ion dimension has 4096 lines, so the total data set is 1G data points (4 Gbytes). The fragment ion coverage obtained with a blind, unoptimized 2D FT-ICR MS experiment was lower than conventional MS/MS, but MS/MS information is obtained for all ions in the sample regardless of selection and isolation. Finally, although all 2D FT-ICR MS peak assignments were made with the aid of 1D FT-ICR MS data, these results

  11. Computational mass spectrometry for small molecules

    PubMed Central

    2013-01-01

    The identification of small molecules from mass spectrometry (MS) data remains a major challenge in the interpretation of MS data. This review covers the computational aspects of identifying small molecules, from the identification of a compound searching a reference spectral library, to the structural elucidation of unknowns. In detail, we describe the basic principles and pitfalls of searching mass spectral reference libraries. Determining the molecular formula of the compound can serve as a basis for subsequent structural elucidation; consequently, we cover different methods for molecular formula identification, focussing on isotope pattern analysis. We then discuss automated methods to deal with mass spectra of compounds that are not present in spectral libraries, and provide an insight into de novo analysis of fragmentation spectra using fragmentation trees. In addition, this review shortly covers the reconstruction of metabolic networks using MS data. Finally, we list available software for different steps of the analysis pipeline. PMID:23453222

  12. Alpha spectrometry applications with mass separated samples.

    PubMed

    Dion, M P; Eiden, Gregory C; Farmer, Orville T; Liezers, Martin; Robinson, John W

    2016-01-01

    (241)Am has been deposited using a novel technique that employs a commercial inductively coupled plasma mass spectrometer. This work presents results of high-resolution alpha spectrometry on the (241)Am samples using a small area passivated implanted planar silicon detector. We have also investigated the mass-based separation capability by developing a (238)Pu sample, present as a minor constituent in a (244)Pu standard, and performed subsequent radiometric counting. With this new sample development method, the (241)Am samples achieved the intrinsic energy resolution of the detector used for these measurements. There was no detectable trace of any other isotopes contained in the (238)Pu implant demonstrating the mass-based separation (or enhancement) attainable with this technique. PMID:26583262

  13. Analysis of Glycosaminoglycans Using Mass Spectrometry

    PubMed Central

    Staples, Gregory O.; Zaia, Joseph

    2015-01-01

    The glycosaminoglycans (GAGs) are linear polysaccharides expressed on animal cell surfaces and in extracellular matrices. Their biosynthesis is under complex control and confers a domain structure that is essential to their ability to bind to protein partners. Key to understanding the functions of GAGs are methods to determine accurately and rapidly patterns of sulfation, acetylation and uronic acid epimerization that correlate with protein binding or other biological activities. Mass spectrometry (MS) is particularly suitable for the analysis of GAGs for biomedical purposes. Using modern ionization techniques it is possible to accurately determine molecular weights of GAG oligosaccharides and their distributions within a mixture. Methods for direct interfacing with liquid chromatography have been developed to permit online mass spectrometric analysis of GAGs. New tandem mass spectrometric methods for fine structure determination of GAGs are emerging. This review summarizes MS-based approaches for analysis of GAGs, including tissue extraction and chromatographic methods compatible with LC/MS and tandem MS. PMID:25705143

  14. Desorption electrospray ionisation mass spectrometry and tandem mass spectrometry of low molecular weight synthetic polymers.

    PubMed

    Jackson, Anthony T; Williams, Jonathan P; Scrivens, James H

    2006-01-01

    A range of low molecular weight synthetic polymers has been characterised by means of desorption electrospray ionisation (DESI) combined with both mass spectrometry (MS) and tandem mass spectrometry (MS/MS). Accurate mass experiments were used to aid the structural determination of some of the oligomeric materials. The polymers analysed were poly(ethylene glycol) (PEG), polypropylene glycol (PPG), poly(methyl methacrylate) (PMMA) and poly(alpha-methyl styrene). An application of the technique for characterisation of a polymer used as part of an active ingredient in a pharmaceutical tablet is described. The mass spectra and tandem mass spectra of all of the polymers were obtained in seconds, indicating the sensitivity of the technique. PMID:16912984

  15. Membrane composition analysis by imaging mass spectrometry

    SciTech Connect

    Boxer, S G; Kraft, M L; Longo, M; Hutcheon, I D; Weber, P K

    2006-03-29

    Membranes on solid supports offer an ideal format for imaging. Secondary ion mass spectrometry (SIMS) can be used to obtain composition information on membrane-associated components. Using the NanoSIMS50, images of composition variations in membrane domains can be obtained with a lateral resolution better than 100 nm. By suitable calibration, these variations in composition can be translated into a quantitative analysis of the membrane composition. Progress towards imaging small phase-separated lipid domains, membrane-associated proteins and natural biological membranes will be described.

  16. Study of CPP Mechanisms by Mass Spectrometry.

    PubMed

    Sagan, Sandrine; Bechara, Chérine; Burlina, Fabienne

    2015-01-01

    Studying the mechanisms of entry of cell-penetrating peptides (CPPs) requires reliable methods to measure their cellular uptake efficiency, monitor their metabolic stability, and identify their intracellular localization. We describe here a protocol based on the direct detection of peptides by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS), which allows the absolute quantification of the intact internalized species and the analysis of their intracellular degradation. This protocol can be easily applied to the simultaneous quantification of different species, for example mixtures of CPPs. PMID:26202265

  17. Quantification of diacylglycerol by mass spectrometry.

    PubMed

    vom Dorp, Katharina; Dombrink, Isabel; Dörmann, Peter

    2013-01-01

    Diacylglycerol (DAG) is an important intermediate of lipid metabolism and a component of phospholipase C signal transduction. Quantification of DAG in plant membranes represents a challenging task because of its low abundance. DAG can be measured by direct infusion mass spectrometry (MS) on a quadrupole time-of-flight mass spectrometer after purification from the crude plant lipid extract via solid-phase extraction on silica columns. Different internal standards are employed to compensate for the dependence of the MS and MS/MS signals on the chain length and the presence of double bonds in the acyl moieties. Thus, using a combination of single MS and MS/MS experiments, quantitative results for the different molecular species of DAGs from Arabidopsis can be obtained. PMID:23681522

  18. Mass Spectrometry for Rapid Characterization of Microorganisms

    NASA Astrophysics Data System (ADS)

    Demirev, Plamen A.; Fenselau, Catherine

    2008-07-01

    Advances in instrumentation, proteomics, and bioinformatics have contributed to the successful applications of mass spectrometry (MS) for detection, identification, and classification of microorganisms. These MS applications are based on the detection of organism-specific biomarker molecules, which allow differentiation between organisms to be made. Intact proteins, their proteolytic peptides, and nonribosomal peptides have been successfully utilized as biomarkers. Sequence-specific fragments for biomarkers are generated by tandem MS of intact proteins or proteolytic peptides, obtained after, for instance, microwave-assisted acid hydrolysis. In combination with proteome database searching, individual biomarker proteins are unambiguously identified from their tandem mass spectra, and from there the source microorganism is also identified. Such top-down or bottom-up proteomics approaches permit rapid, sensitive, and confident characterization of individual microorganisms in mixtures and are reviewed here. Examples of MS-based functional assays for detection of targeted microorganisms, e.g., Bacillus anthracis, in environmental or clinically relevant backgrounds are also reviewed.

  19. Protein Sequencing with Tandem Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Ziady, Assem G.; Kinter, Michael

    The recent introduction of electrospray ionization techniques that are suitable for peptides and whole proteins has allowed for the design of mass spectrometric protocols that provide accurate sequence information for proteins. The advantages gained by these approaches over traditional Edman Degradation sequencing include faster analysis and femtomole, sometimes attomole, sensitivity. The ability to efficiently identify proteins has allowed investigators to conduct studies on their differential expression or modification in response to various treatments or disease states. In this chapter, we discuss the use of electrospray tandem mass spectrometry, a technique whereby protein-derived peptides are subjected to fragmentation in the gas phase, revealing sequence information for the protein. This powerful technique has been instrumental for the study of proteins and markers associated with various disorders, including heart disease, cancer, and cystic fibrosis. We use the study of protein expression in cystic fibrosis as an example.

  20. Accelerator mass spectrometry: Proceedings of the fourth international symposium on accelerator mass spectrometry

    SciTech Connect

    Gove, H.E.; Litherland, A.E.; Elmore, D.

    1987-01-01

    This report is a volume of the journal Nuclear Instruments and Methods in Physics Research B: Beam Interactions with Materials and Atoms. This particular volume is concerned with accelerator mass spectrometry. The sections of this issue are: Advances in AMS techniques; Archaeology and ecology; Glaciology and climatology; Cosmochemistry and in situ production; Ocean and atmospheric sciences; Hydrology and geology; Astrophysics, nuclear physics and lasers.

  1. Mass Spectrometry on Future Mars Landers

    NASA Technical Reports Server (NTRS)

    Brinckerhoff, W. B.; Mahaffy, P. R.

    2011-01-01

    Mass spectrometry investigations on the 2011 Mars Science Laboratory (MSL) and the 2018 ExoMars missions will address core science objectives related to the potential habitability of their landing site environments and more generally the near-surface organic inventory of Mars. The analysis of complex solid samples by mass spectrometry is a well-known approach that can provide a broad and sensitive survey of organic and inorganic compounds as well as supportive data for mineralogical analysis. The science value of such compositional information is maximized when one appreciates the particular opportunities and limitations of in situ analysis with resource-constrained instrumentation in the context of a complete science payload and applied to materials found in a particular environment. The Sample Analysis at Mars (SAM) investigation on MSL and the Mars Organic Molecule Analyzer (MOMA) investigation on ExoMars will thus benefit from and inform broad-based analog field site work linked to the Mars environments where such analysis will occur.

  2. Secondary Ion Mass Spectrometry of Environmental Aerosols

    SciTech Connect

    Gaspar, Daniel J.; Cliff, John B.

    2010-08-01

    Atmospheric particles influence many aspects of climate, air quality and human health. Understanding the composition, chemistry and behavior of atmospheric aerosols is a key remaining challenge in improving climate models. Furthermore, particles may be traced back to a particular source based on composition, stable isotope ratios, or the presence of particular surface chemistries. Finally, the characterization of atmospheric particles in the workplace plays an important role in understanding the potential for exposure and environmental and human health effects to engineered and natural nanoscale particles. Secondary ion mass spectrometry (SIMS) is a useful tool in determining any of several aspects of the structure, composition and chemistry of these particles. Often used in conjunction with other surface analysis and electron microscopy methods, SIMS has been used to determine or confirm reactions on and in particles, the presence of particular organic species on the surface of atmospheric aerosols and several other interesting and relevant findings. Various versions of SIMS instruments – dynamic SIMS, time of flight secondary ion mass spectrometry or TOF-SIMS, nanoSIMS – have been used to determine specific aspects of aerosol structure and chemistry. This article describes the strengths of each type of SIMS instrument in the characterization of aerosols, along with guidance on sample preparation, specific characterization specific to the particular information sought in the analysis. Examples and guidance are given for each type of SIMS analysis.

  3. [Application of mass spectrometry in mycobacteria].

    PubMed

    Alcaide, Fernando; Palop-Borrás, Begoña; Domingo, Diego; Tudó, Griselda

    2016-06-01

    To date, more than 170 species of mycobacteria have been described, of which more than one third may be pathogenic to humans, representing a significant workload for microbiology laboratories. These species must be identified in clinical practice, which has long been a major problem due to the shortcomings of conventional (phenotypic) methods and the limitations and complexity of modern methods largely based on molecular biology techniques. The aim of this review was to briefly describe different aspects related to the use of MALDI-TOF (matrix-assisted laser desorption ionization time-of-flight) mass spectrometry (MS) for the identification of mycobacteria. Several difficulties are encountered with the use of this methodology in these microorganisms mainly due to the high pathogenicity of some mycobacteria and the peculiar structure of their cell wall, requiring inactivation and special protein extraction protocols. We also analysed other relevant aspects such as culture media, the reference methods employed (gold standard) in the final identification of the different species, the cut-off used to accept data as valid, and the databases of the different mass spectrometry systems available. MS has revolutionized diagnosis in modern microbiology; however, specific improvements are needed to consolidate the use of this technology in mycobacteriology. PMID:27389290

  4. Spatial Autocorrelation in Mass Spectrometry Imaging.

    PubMed

    Cassese, Alberto; Ellis, Shane R; Ogrinc Potočnik, Nina; Burgermeister, Elke; Ebert, Matthias; Walch, Axel; van den Maagdenberg, Arn M J M; McDonnell, Liam A; Heeren, Ron M A; Balluff, Benjamin

    2016-06-01

    Mass spectrometry imaging (MSI) is a powerful molecular imaging technique. In microprobe MSI, images are created through a grid-wise interrogation of individual spots by mass spectrometry across a surface. Classical statistical tests for within-sample comparisons fail as close-by measurement spots violate the assumption of independence of these tests, which can lead to an increased false-discovery rate. For spatial data, this effect is referred to as spatial autocorrelation. In this study, we investigated spatial autocorrelation in three different matrix-assisted laser desorption/ionization MSI data sets. These data sets cover different molecular classes (metabolites/drugs, lipids, and proteins) and different spatial resolutions ranging from 20 to 100 μm. Significant spatial autocorrelation was detected in all three data sets and found to increase with decreasing pixel size. To enable statistical testing for differences in mass signal intensities between regions of interest within MSI data sets, we propose the use of Conditional Autoregressive (CAR) models. We show that, by accounting for spatial autocorrelation, discovery rates (i.e., the ratio between the features identified and the total number of features) could be reduced between 21% and 69%. The reliability of this approach was validated by control mass signals based on prior knowledge. In light of the advent of larger MSI data sets based on either an increased spatial resolution or 3D data sets, accounting for effects due to spatial autocorrelation becomes even more indispensable. Here, we propose a generic and easily applicable workflow to enable within-sample statistical comparisons. PMID:27180608

  5. SUPER-CRITICAL GROWTH OF MASSIVE BLACK HOLES FROM STELLAR-MASS SEEDS

    SciTech Connect

    Madau, Piero; Haardt, Francesco; Dotti, Massimo

    2014-04-01

    We consider super-critical accretion with angular momentum onto stellar-mass black holes as a possible mechanism for growing billion-solar-mass black holes from light seeds at early times. We use the radiatively inefficient ''slim disk'' solution—advective, optically thick flows that generalize the standard geometrically thin disk model—to show how mildly super-Eddington intermittent accretion may significantly ease the problem of assembling the first massive black holes when the universe was less than 0.8 Gyr old. Because of the low radiative efficiencies of slim disks around non-rotating as well as rapidly rotating black holes, the mass e-folding timescale in this regime is nearly independent of the spin parameter. The conditions that may lead to super-critical growth in the early universe are briefly discussed.

  6. Neutral particle mass spectrometry with nanomechanical systems

    PubMed Central

    Sage, Eric; Brenac, Ariel; Alava, Thomas; Morel, Robert; Dupré, Cécilia; Hanay, Mehmet Selim; Roukes, Michael L.; Duraffourg, Laurent; Masselon, Christophe; Hentz, Sébastien

    2015-01-01

    Current approaches to mass spectrometry (MS) require ionization of the analytes of interest. For high-mass species, the resulting charge state distribution can be complex and difficult to interpret correctly. Here, using a setup comprising both conventional time-of-flight MS (TOF-MS) and nano-electromechanical systems-based MS (NEMS-MS) in situ, we show directly that NEMS-MS analysis is insensitive to charge state: the spectrum consists of a single peak whatever the species’ charge state, making it significantly clearer than existing MS analysis. In subsequent tests, all the charged particles are electrostatically removed from the beam, and unlike TOF-MS, NEMS-MS can still measure masses. This demonstrates the possibility to measure mass spectra for neutral particles. Thus, it is possible to envisage MS-based studies of analytes that are incompatible with current ionization techniques and the way is now open for the development of cutting-edge system architectures with unique analytical capability. PMID:25753929

  7. Crux: rapid open source protein tandem mass spectrometry analysis.

    PubMed

    McIlwain, Sean; Tamura, Kaipo; Kertesz-Farkas, Attila; Grant, Charles E; Diament, Benjamin; Frewen, Barbara; Howbert, J Jeffry; Hoopmann, Michael R; Käll, Lukas; Eng, Jimmy K; MacCoss, Michael J; Noble, William Stafford

    2014-10-01

    Efficiently and accurately analyzing big protein tandem mass spectrometry data sets requires robust software that incorporates state-of-the-art computational, machine learning, and statistical methods. The Crux mass spectrometry analysis software toolkit ( http://cruxtoolkit.sourceforge.net ) is an open source project that aims to provide users with a cross-platform suite of analysis tools for interpreting protein mass spectrometry data. PMID:25182276

  8. Multinozzle Emitter Arrays for Nanoelectrospray Mass Spectrometry

    SciTech Connect

    Mao, Pan; Wang, Hung-Ta; Yang, Peidong; Wang, Daojing

    2011-06-16

    Mass spectrometry (MS) is the enabling technology for proteomics and metabolomics. However, dramatic improvements in both sensitivity and throughput are still required to achieve routine MS-based single cell proteomics and metabolomics. Here, we report the silicon-based monolithic multinozzle emitter array (MEA), and demonstrate its proof-of-principle applications in high-sensitivity and high-throughput nanoelectrospray mass spectrometry. Our MEA consists of 96 identical 10-nozzle emitters in a circular array on a 3-inch silicon chip. The geometry and configuration of the emitters, the dimension and number of the nozzles, and the micropillar arrays embedded in the main channel, can be systematically and precisely controlled during the microfabrication process. Combining electrostatic simulation and experimental testing, we demonstrated that sharpened-end geometry at the stem of the individual multinozzle emitter significantly enhanced the electric fields at its protruding nozzle tips, enabling sequential nanoelectrospray for the high-density emitter array. We showed that electrospray current of the multinozzle emitter at a given total flow rate was approximately proportional to the square root of the number of its spraying-nozzles, suggesting the capability of high MS sensitivity for multinozzle emitters. Using a conventional Z-spray mass spectrometer, we demonstrated reproducible MS detection of peptides and proteins for serial MEA emitters, achieving sensitivity and stability comparable to the commercial capillary emitters. Our robust silicon-based MEA chip opens up the possibility of a fully-integrated microfluidic system for ultrahigh-sensitivity and ultrahigh-throughput proteomics and metabolomics.

  9. Laser Microprobe Mass Spectrometry 1: Basic Principles and Performance Characteristics.

    ERIC Educational Resources Information Center

    Denoyer, Eric; And Others

    1982-01-01

    Describes the historical development, performance characteristics (sample requirements, analysis time, ionization characteristics, speciation capabilities, and figures of merit), and applications of laser microprobe mass spectrometry. (JN)

  10. New analytical scheme for regular old ordinary mass spectrometry

    SciTech Connect

    Lewis, T.M.; Russell, D.

    1994-12-31

    A unified scheme was developed to define the composition, improve detection and qualitative identification of water soluble organics in heavy oil retort. Elements of the scheme included gas chromatography-mass spectrometry (GC-MS), high resolution mass spectrometry (HRMS), hybrid mass spectrometry-mass spectrometry (EB-TOF) with electron impact (EI) and fast atom bombardment (FAB) ionization and a computerized library search program. As part of the development of the process, each element of the analytical scheme was applied to complex samples of aqueous organic materials extracted from heavy oil retorts. Preliminary investigations have indicated that the heavy oil retort contains hundreds of compounds in ppm/ppb concentrations.

  11. Feature extraction and dimensionality reduction for mass spectrometry data.

    PubMed

    Liu, Yihui

    2009-09-01

    Mass spectrometry is being used to generate protein profiles from human serum, and proteomic data obtained from mass spectrometry have attracted great interest for the detection of early stage cancer. However, high dimensional mass spectrometry data cause considerable challenges. In this paper we propose a feature extraction algorithm based on wavelet analysis for high dimensional mass spectrometry data. A set of wavelet detail coefficients at different scale is used to detect the transient changes of mass spectrometry data. The experiments are performed on 2 datasets. A highly competitive accuracy, compared with the best performance of other kinds of classification models, is achieved. Experimental results show that the wavelet detail coefficients are efficient way to characterize features of high dimensional mass spectra and reduce the dimensionality of high dimensional mass spectra. PMID:19646687

  12. Characterisation of DEFB107 by mass spectrometry

    NASA Astrophysics Data System (ADS)

    McCullough, Bryan J.; Eastwood, Hayden; Clark, Dave J.; Polfer, Nick C.; Campopiano, Dominic J.; Dorin, Julia A.; Maxwell, Alison; Langley, Ross J.; Govan, John R. W.; Bernstein, Summer L.; Bowers, Michael T.; Barran, Perdita E.

    2006-05-01

    Mammalian defensins are small endogenous cationic proteins which form a class of antimicrobial peptides that is part of the innate immune response of all mammalian species [R. Lehrer, Nat. Rev. Microbiol. 2 (9) (2004) 727; T. Ganz, R.I. Lehrer, Curr. Opin. Immunol. 6 (4) (1994) 584] [1] and [2]. We have developed mass spectrometry based strategies for characterising the structure-activity relationship of defensins [D.J. Campopiano, D.J. Clarke, N.C. Polfer, P.E. Barran, R.J. Langley, J.R.W. Govan, A. Maxwell, J.R. Dorin, J. Biol. Chem. 279 (47) (2004) 48671; P.E. Barran, N.C. Polfer, D.J. Campopiano, D.J. Clarke, P.R.R. Langridge-Smith, R.J. Langley, J.R.W. Govan, A. Maxwell, J.R. Dorin, R.P. Millar, M.T. Bowers, Int. J. Mass Spectrom. 240 (2005) 273] [3] and [4], and here we present data obtained from a five cysteine containing [beta]-defensin, DEFB107. The synthetic product of this human defensin exists with a glutathione capping group, its oxidation state and disulphide connectivity have been determined via accurate mass measurements and peptide mass mapping respectively, and despite possessing three disulphide bridges, it does not fit the [beta]-defensin canonical motif. With the use of molecular modelling, we have generated candidate geometries to discern the influence of disulphide bridging on the overall tertiary structure of DEFB107. These are compared with experimental results from ion mobility measurements. Defensins display activity against a wide variety of pathogens including both gram-negative and gram-positive bacteria. Their mechanism of mode of action is unknown, but is believed to involve defensin aggregation at cell surfaces, followed by cell permeabilisation and hence deathE To probe this mechanism, the localisation of DEFB107 in synthetic vesicles was studied using H/D exchange and mass spectrometry. The results obtained are used to analyse the antimicrobial activity of DEFB107.

  13. Laser Ablation Inductively Coupled Plasma Mass Spectrometry

    PubMed Central

    Hutchinson, Robert W.; McLachlin, Katherine M.; Riquelme, Paloma; Haarer, Jan; Broichhausen, Christiane; Ritter, Uwe; Geissler, Edward K.; Hutchinson, James A.

    2015-01-01

    ABSTRACT New analytical techniques for multiparametric characterisation of individual cells are likely to reveal important information about the heterogeneity of immunological responses at the single-cell level. In this proof-of-principle study, laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was applied to the problem of concurrently detecting 24 lineage and activation markers expressed by human leucocytes. This approach was sufficiently sensitive and specific to identify subpopulations of isolated T, B, and natural killer cells. Leucocyte subsets were also accurately detected within unfractionated peripheral blood mononuclear cells preparations. Accordingly, we judge LA-ICP-MS to be a suitable method for assessing expression of multiple tissue antigens in solid-phase biological specimens, such as tissue sections, cytospins, or cells grown on slides. These results augur well for future development of LA-ICP-MS–based bioimaging instruments for general users. PMID:27500232

  14. Mass Spectrometry Methodology in Lipid Analysis

    PubMed Central

    Li, Lin; Han, Juanjuan; Wang, Zhenpeng; Liu, Jian’an; Wei, Jinchao; Xiong, Shaoxiang; Zhao, Zhenwen

    2014-01-01

    Lipidomics is an emerging field, where the structures, functions and dynamic changes of lipids in cells, tissues or body fluids are investigated. Due to the vital roles of lipids in human physiological and pathological processes, lipidomics is attracting more and more attentions. However, because of the diversity and complexity of lipids, lipid analysis is still full of challenges. The recent development of methods for lipid extraction and analysis and the combination with bioinformatics technology greatly push forward the study of lipidomics. Among them, mass spectrometry (MS) is the most important technology for lipid analysis. In this review, the methodology based on MS for lipid analysis was introduced. It is believed that along with the rapid development of MS and its further applications to lipid analysis, more functional lipids will be identified as biomarkers and therapeutic targets and for the study of the mechanisms of disease. PMID:24921707

  15. Quantitative mass spectrometry of urinary biomarkers

    PubMed Central

    Jerebtsova, Marina; Nekhai, Sergei

    2015-01-01

    The effectiveness of treatment of renal diseases is limited because the lack of diagnostic, prognostic and therapeutic markers. Despite the more than a decade of intensive investigation of urinary biomarkers, no new clinical biomarkers were approved. This is in part because the early expectations toward proteomics in biomarkers discovery were significantly higher than the capability of technology at the time. However, during the last decade, proteomic technology has made dramatic progress in both the hardware and software methods. In this review we are discussing modern quantitative methods of mass-spectrometry and providing several examples of their applications for discovery and validation of renal disease biomarkers. We are optimistic about future prospects for the development of novel of specific clinical urinary biomarkers. PMID:25984422

  16. Recent trends in inorganic mass spectrometry

    SciTech Connect

    Smith, D.H.; Barshick, C.M.; Duckworth, D.C.; Riciputi, L.R.

    1996-10-01

    The field of inorganic mass spectrometry has seen substantial change in the author`s professional lifetime (over 30 years). Techniques in their infancy 30 years ago have matured; some have almost disappeared. New and previously unthought of techniques have come into being; some of these, such as ICP-MS, are reasonably mature now, while others have some distance to go before they can be so considered. Most of these new areas provide fertile fields for researchers, both in the development of new analytical techniques and by allowing fundamental studies to be undertaken that were previously difficult, impossible, or completely unforeseen. As full coverage of the field is manifestly impossible within the framework of this paper, only those areas with which the author has personal contact will be discussed. Most of the work originated in his own laboratory, but that of other laboratories is covered where it seemed appropriate.

  17. In situ secondary ion mass spectrometry analysis

    SciTech Connect

    Groenewold, G.S.; Applehans, A.D.; Ingram, J.C.; Delmore, J.E.; Dahl, D.A.

    1993-01-01

    The direct detection of tributyl phosphate (TBP) on rocks using molecular beam surface analysis [MBSA or in situ secondary ion mass spectrometry (SIMS)] is demonstrated. Quantities as low as 250 ng were detected on basalt and sandstone with little or no sample preparation. Detection of TBP on soil has proven to be more problematic and requires further study. Ethylenediaminetetraacetic acid (EDTA) is more difficult to detect because it is very reactive with surfaces of interest. Nevertheless, it is possible to detect EDTA if the acidity of the surface is controlled. The detection of EDTA-metal complexes is currently an open question, but evidence is presented for the detection of ions arising from a EDTA-lead complex. Carboxylic acids (i.e., citric, ascorbic, malic, succinic, malonic, and oxalic) give characteristic SIM spectra, but their detection on sample surfaces awaits evaluation.

  18. [Application of mass spectrometry in mycology].

    PubMed

    Quiles Melero, Inmaculada; Peláez, Teresa; Rezusta López, Antonio; Garcia-Rodríguez, Julio

    2016-06-01

    MALDI-TOF (matrix-assisted laser desorption ionization time-of-flight) mass spectrometry (MS) is becoming an essential tool in most microbiology laboratories. At present, by using a characteristic fungal profile obtained from whole cells or through simple extraction protocols, MALDI-TOF MS allows the identification of pathogenic fungi with a high performance potential. This methodology decreases the laboratory turnaround time, optimizing the detection of mycoses. This article describes the state-of-the-art of the use of MALDI-TOF MS for the detection of human clinical fungal pathogens in the laboratory and discusses the future applications of this technology, which will further improve routine mycological diagnosis. PMID:27389289

  19. China's food safety regulation and mass spectrometry.

    PubMed

    Chu, Xiaogang; Zhang, Feng; Nie, Xuemei; Wang, Wenzhi; Feng, Feng

    2011-01-01

    Food safety is essential to people's health and people's livelihood. To ensure that food safety is an important current strategy of the governments, both regulation and standardization are important support for implementing this strategic initiative effectively. The status and prospects of China's food laws, regulations, and standards system are introduced. China now has established a complete law regime providing a sound foundation and good environment for keeping the health of people, maintaining the order of social economy and promoting the international trade of food. At the same time, it is undoubtedly important to strengthen standardization and improve the food safety standards system. In the administration of food safety, mass spectrometry is becoming more and more important and many analytical methods developed in China are based on its application. PMID:21643903

  20. Electrostatic-spray ionization mass spectrometry.

    PubMed

    Qiao, Liang; Sartor, Romain; Gasilova, Natalia; Lu, Yu; Tobolkina, Elena; Liu, Baohong; Girault, Hubert H

    2012-09-01

    An electrostatic-spray ionization (ESTASI) method has been used for mass spectrometry (MS) analysis of samples deposited in or on an insulating substrate. The ionization is induced by a capacitive coupling between an electrode and the sample. In practice, a metallic electrode is placed close to but not in direct contact with the sample. Upon application of a high voltage pulse to the electrode, an electrostatic charging of the sample occurs leading to a bipolar spray pulse. When the voltage is positive, the bipolar spray pulse consists first of cations and then of anions. This method has been applied to a wide range of geometries to emit ions from samples in a silica capillary, in a disposable pipet tip, in a polymer microchannel, or from samples deposited as droplets on a polymer plate. Fractions from capillary electrophoresis were collected on a polymer plate for ESTASI MS analysis. PMID:22876737

  1. Forensic applications of ambient ionization mass spectrometry.

    PubMed

    Ifa, Demian R; Jackson, Ayanna U; Paglia, Giuseppe; Cooks, R Graham

    2009-08-01

    This review highlights and critically assesses forensic applications in the developing field of ambient ionization mass spectrometry. Ambient ionization methods permit the ionization of samples outside the mass spectrometer in the ordinary atmosphere, with minimal sample preparation. Several ambient ionization methods have been created since 2004 and they utilize different mechanisms to create ions for mass-spectrometric analysis. Forensic applications of these techniques--to the analysis of toxic industrial compounds, chemical warfare agents, illicit drugs and formulations, explosives, foodstuff, inks, fingerprints, and skin--are reviewed. The minimal sample pretreatment needed is illustrated with examples of analysis from complex matrices (e.g., food) on various substrates (e.g., paper). The low limits of detection achieved by most of the ambient ionization methods for compounds of forensic interest readily offer qualitative confirmation of chemical identity; in some cases quantitative data are also available. The forensic applications of ambient ionization methods are a growing research field and there are still many types of applications which remain to be explored, particularly those involving on-site analysis. Aspects of ambient ionization currently undergoing rapid development include molecular imaging and increased detection specificity through simultaneous chemical reaction and ionization by addition of appropriate chemical reagents. PMID:19241065

  2. Atmospheric-pressure Penning ionization mass spectrometry.

    PubMed

    Hiraoka, Kenzo; Fujimaki, Susumu; Kambara, Shizuka; Furuya, Hiroko; Okazaki, Shigemitsu

    2004-01-01

    A preliminary study on the atmospheric-pressure Penning ionization (APP(e)I) of gaseous organic compounds with Ar* has been made. The metastable argon atoms (Ar*: 11.55 eV for (3)P(2) and 11.72 eV for (3)P(0)) were generated by the negative-mode corona discharge of atmospheric-pressure argon gas. By applying a high positive voltage (+500 to +1000 V) to the stainless steel capillary for the sample introduction (0.1 mm i.d., 0.3 mm o.d.), strong ion signals could be obtained. The ions formed were sampled through an orifice into the vacuum and mass-analyzed by an orthogonal time-of-flight mass spectrometer. The major ions formed by APP(e)I are found to be molecular-related ions for alkanes, aromatics, and oxygen-containing compounds. Because only the molecules with ionization energies less than the internal energy of Ar* are ionized, the present method will be a selective and highly sensitive interface for gas chromatography/mass spectrometry. PMID:15384154

  3. Visualizing nanoparticle dissolution by imaging mass spectrometry.

    PubMed

    Szakal, Christopher; Ugelow, Melissa S; Gorham, Justin M; Konicek, Andrew R; Holbrook, R David

    2014-04-01

    We demonstrate the ability to visualize nanoparticle dissolution while simultaneously providing chemical signatures that differentiate between citrate-capped silver nanoparticles (AgNPs), AgNPs forced into dissolution via exposure to UV radiation, silver nitrate (AgNO3), and AgNO3/citrate deposited from aqueous solutions and suspensions. We utilize recently developed inkjet printing (IJP) protocols to deposit the different solutions/suspensions as NP aggregates and soluble species, which separate onto surfaces in situ, and collect mass spectral imaging data via time-of-flight secondary ion mass spectrometry (TOF-SIMS). Resulting 2D Ag(+) chemical images provide the ability to distinguish between the different Ag-containing starting materials and, when coupled with mass spectral peak ratios, provide information-rich data sets for quick and reproducible visualization of NP-based aqueous constituents. When compared to other measurements aimed at studying NP dissolution, the IJP-TOF-SIMS approach offers valuable information that can potentially help in understanding the complex equilibria in NP-containing solutions and suspensions, including NP dissolution kinetics and extent of overall dissolution. PMID:24611464

  4. Advances in imaging secondary ion mass spectrometry for biological samples

    SciTech Connect

    Boxer, Steven G.; Kraft, Mary L.; Weber, Peter K.

    2008-12-16

    Imaging mass spectrometry combines the power of mass spectrometry to identify complex molecules based on mass with sample imaging. Recent advances in secondary ion mass spectrometry have improved sensitivity and spatial resolution, so that these methods have the potential to bridge between high-resolution structures obtained by X-ray crystallography and cyro-electron microscopy and ultrastructure visualized by conventional light microscopy. Following background information on the method and instrumentation, we address the key issue of sample preparation. Because mass spectrometry is performed in high vacuum, it is essential to preserve the lateral organization of the sample while removing bulk water, and this has been a major barrier for applications to biological systems. Furthermore, recent applications of imaging mass spectrometry to cell biology, microbial communities, and biosynthetic pathways are summarized briefly, and studies of biological membrane organization are described in greater depth.

  5. Advances in imaging secondary ion mass spectrometry for biological samples

    DOE PAGESBeta

    Boxer, Steven G.; Kraft, Mary L.; Weber, Peter K.

    2008-12-16

    Imaging mass spectrometry combines the power of mass spectrometry to identify complex molecules based on mass with sample imaging. Recent advances in secondary ion mass spectrometry have improved sensitivity and spatial resolution, so that these methods have the potential to bridge between high-resolution structures obtained by X-ray crystallography and cyro-electron microscopy and ultrastructure visualized by conventional light microscopy. Following background information on the method and instrumentation, we address the key issue of sample preparation. Because mass spectrometry is performed in high vacuum, it is essential to preserve the lateral organization of the sample while removing bulk water, and this hasmore » been a major barrier for applications to biological systems. Furthermore, recent applications of imaging mass spectrometry to cell biology, microbial communities, and biosynthetic pathways are summarized briefly, and studies of biological membrane organization are described in greater depth.« less

  6. Mass Spectrometry of Acoustically Levitated Droplets

    PubMed Central

    Westphall, Michael S.; Jorabchi, Kaveh; Smith, Lloyd M.

    2008-01-01

    Containerless sample handling techniques such as acoustic levitation offer potential advantages for mass spectrometry, by eliminating surfaces where undesired adsorption/desorption processes can occur. In addition, they provide a unique opportunity to study fundamental aspects of the ionization process as well as phenomena occurring at the air–droplet interface. Realizing these advantages is contingent, however, upon being able to effectively interface levitated droplets with a mass spectrometer, a challenging task that is addressed in this report. We have employed a newly developed charge and matrix-assisted laser desorption/ionization (CALDI) technique to obtain mass spectra from a 5-μL acoustically levitated droplet containing peptides and an ionic matrix. A four-ring electrostatic lens is used in conjunction with a corona needle to produce bursts of corona ions and to direct those ions toward the droplet, resulting in droplet charging. Analyte ions are produced from the droplet by a 337-nm laser pulse and detected by an atmospheric sampling mass spectrometer. The ion generation and extraction cycle is repeated at 20 Hz, the maximum operating frequency of the laser employed. It is shown in delayed ion extraction experiments that both positive and negative ions are produced, behavior similar to that observed for atmospheric pressure matrix-assisted laser absorption/ionization. No ion signal is observed in the absence of droplet charging. It is likely, although not yet proven, that the role of the droplet charging is to increase the strength of the electric field at the surface of the droplet, reducing chargere combination after ion desorption. PMID:18582090

  7. Mass spectrometry of acoustically levitated droplets.

    PubMed

    Westphall, Michael S; Jorabchi, Kaveh; Smith, Lloyd M

    2008-08-01

    Containerless sample handling techniques such as acoustic levitation offer potential advantages for mass spectrometry, by eliminating surfaces where undesired adsorption/desorption processes can occur. In addition, they provide a unique opportunity to study fundamental aspects of the ionization process as well as phenomena occurring at the air-droplet interface. Realizing these advantages is contingent, however, upon being able to effectively interface levitated droplets with a mass spectrometer, a challenging task that is addressed in this report. We have employed a newly developed charge and matrix-assisted laser desorption/ionization (CALDI) technique to obtain mass spectra from a 5-microL acoustically levitated droplet containing peptides and an ionic matrix. A four-ring electrostatic lens is used in conjunction with a corona needle to produce bursts of corona ions and to direct those ions toward the droplet, resulting in droplet charging. Analyte ions are produced from the droplet by a 337-nm laser pulse and detected by an atmospheric sampling mass spectrometer. The ion generation and extraction cycle is repeated at 20 Hz, the maximum operating frequency of the laser employed. It is shown in delayed ion extraction experiments that both positive and negative ions are produced, behavior similar to that observed for atmospheric pressure matrix-assisted laser absorption/ionization. No ion signal is observed in the absence of droplet charging. It is likely, although not yet proven, that the role of the droplet charging is to increase the strength of the electric field at the surface of the droplet, reducing charge recombination after ion desorption. PMID:18582090

  8. Single-protein nanomechanical mass spectrometry in real time

    PubMed Central

    Hanay, M.S.; Kelber, S.; Naik, A.K.; Chi, D.; Hentz, S.; Bullard, E.C.; Colinet, E.; Duraffourg, L.; Roukes, M.L.

    2012-01-01

    Nanoelectromechanical systems (NEMS) resonators can detect mass with exceptional sensitivity. Previously, mass spectra from several hundred adsorption events were assembled in NEMS-based mass spectrometry using statistical analysis. Here, we report the first realization of single-molecule NEMS-based mass spectrometry in real time. As each molecule in the sample adsorbs upon the NEMS resonator, its mass and the position-of-adsorption are determined by continuously tracking two driven vibrational modes of the device. We demonstrate the potential of multimode NEMS-based mass spectrometry by analyzing IgM antibody complexes in real-time. NEMS-MS is a unique and promising new form of mass spectrometry: it can resolve neutral species, provides resolving power that increases markedly for very large masses, and allows acquisition of spectra, molecule-by-molecule, in real-time. PMID:22922541

  9. Compressed sensing in imaging mass spectrometry

    NASA Astrophysics Data System (ADS)

    Bartels, Andreas; Dülk, Patrick; Trede, Dennis; Alexandrov, Theodore; Maaß, Peter

    2013-12-01

    Imaging mass spectrometry (IMS) is a technique of analytical chemistry for spatially resolved, label-free and multipurpose analysis of biological samples that is able to detect the spatial distribution of hundreds of molecules in one experiment. The hyperspectral IMS data is typically generated by a mass spectrometer analyzing the surface of the sample. In this paper, we propose a compressed sensing approach to IMS which potentially allows for faster data acquisition by collecting only a part of the pixels in the hyperspectral image and reconstructing the full image from this data. We present an integrative approach to perform both peak-picking spectra and denoising m/z-images simultaneously, whereas the state of the art data analysis methods solve these problems separately. We provide a proof of the robustness of the recovery of both the spectra and individual channels of the hyperspectral image and propose an algorithm to solve our optimization problem which is based on proximal mappings. The paper concludes with the numerical reconstruction results for an IMS dataset of a rat brain coronal section.

  10. Multidimensional mass spectrometry-based shotgun lipidomics.

    PubMed

    Wang, Miao; Han, Xianlin

    2014-01-01

    Multidimensional mass spectrometry-based shotgun lipidomics (MDMS-SL) has become a foundational analytical technology platform among current lipidomics practices due to its high efficiency, sensitivity, and reproducibility, as well as its broad coverage. This platform has been broadly used to determine the altered content and/or composition of lipid classes, subclasses, and individual molecular species induced by diseases, genetic manipulations, drug treatments, and aging, among others. Herein, we briefly discuss the principles underlying this technology and present a protocol for routine analysis of many of the lipid classes and subclasses covered by MDMS-SL directly from lipid extracts of biological samples. In particular, lipid sample preparation from a variety of biological materials, which is one of the key components of MDMS-SL, is described in detail. The protocol for mass spectrometric analysis can readily be expanded for analysis of other lipid classes not mentioned as long as appropriate sample preparation is conducted, and should aid researchers in the field to better understand and manage the technology for analysis of cellular lipidomes. PMID:25270931

  11. US Food and Drug Administration Perspectives on Clinical Mass Spectrometry.

    PubMed

    Lathrop, Julia Tait; Jeffery, Douglas A; Shea, Yvonne R; Scholl, Peter F; Chan, Maria M

    2016-01-01

    Mass spectrometry-based in vitro diagnostic devices that measure proteins and peptides are underutilized in clinical practice, and none has been cleared or approved by the Food and Drug Administration (FDA) for marketing or for use in clinical trials. One way to increase their utilization is through enhanced interactions between the FDA and the clinical mass spectrometry community to improve the validation and regulatory review of these devices. As a reference point from which to develop these interactions, this article surveys the FDA's regulation of mass spectrometry-based devices, explains how the FDA uses guidance documents and standards in the review process, and describes the FDA's previous outreach to stakeholders. Here we also discuss how further communication and collaboration with the clinical mass spectrometry communities can identify opportunities for the FDA to provide help in the development of mass spectrometry-based devices and enhance their entry into the clinic. PMID:26553791

  12. Applications of Mass Spectrometry to Lipids and Membranes

    PubMed Central

    Harkewicz, Richard; Dennis, Edward A.

    2012-01-01

    Lipidomics, a major part of metabolomics, constitutes the detailed analysis and global characterization, both spatial and temporal, of the structure and function of lipids (the lipidome) within a living system. As with proteomics, mass spectrometry has earned a central analytical role in lipidomics, and this role will continue to grow with technological developments. Currently, there exist two mass spectrometry-based lipidomics approaches, one based on a division of lipids into categories and classes prior to analysis, the “comprehensive lipidomics analysis by separation simplification” (CLASS), and the other in which all lipid species are analyzed together without prior separation, shotgun. In exploring the lipidome of various living systems, novel lipids are being discovered, and mass spectrometry is helping characterize their chemical structure. Deuterium exchange mass spectrometry (DXMS) is being used to investigate the association of lipids and membranes with proteins and enzymes, and imaging mass spectrometry (IMS) is being applied to the in situ analysis of lipids in tissues. PMID:21469951

  13. Mass transfer in SCW extraction molecular diffusion and mass transfer coefficients of ketones and alkenes in sub- and supercritical water

    SciTech Connect

    Goemans, M.G.E.; Gloyna, E.F.

    1996-10-01

    The potential of sub- and supercritical water as extraction solvents has been demonstrated for the (reactive) extraction of coals, used car tires, organic species from residual aqueous solutions, and class selective extraction of organic pollutants with different polarities from solids. In addition, the potential of extraction of coal with supercritical aqueous solutions has been studied. However, physical transport in water at elevated temperature and pressures- and their impact on heterogenous reactions and (reactive) extraction -are not adequately understood. This situation is largely due to the limited data that is available for diffusion in high temperature, high pressure water mixture. Only the molecular diffusion of Iodine ions and hydroquinone in near-critical subcritical water and the self diffusion of coefficient of compressed supercritical water have been reported. In this paper, we present molecular diffusion coefficients of benzophenone, acetone, naphthalene, and anthracene in water at infinite dilution. Pressures ranged from 250 to 500 bar at temperatures ranging from 50{degrees}C to 500{degrees}C resulting in water densities ranging from 1000 to 150 kg/m{sup 3}. Diffusion coefficients were determined by the Taylor-Aris dispersion technique. The effects of increased diffusion on the mass transfer coefficients for emulsions and packed beds were quantified. Molecular division coefficients were 10 to 20 times faster in supercritical water than in water at ambient conditions. Experimental results were correlated with hydrodynamic and kinetic theory. This study and results to be published elsewhere show that diffusion-limited conditions are much more likely to be encountered in supercritical water than is commonly acknowledged.

  14. Glycosaminoglycan Characterization by Electrospray Ionization Mass Spectrometry Including Fourier Transform Mass Spectrometry

    PubMed Central

    Laremore, Tatiana N.; Leach, Franklin E.; Solakyildirim, Kemal; Amster, I. Jonathan; Linhardt, Robert J.

    2011-01-01

    Electrospray ionization mass spectrometry (ESI MS) is a versatile analytical technique in glycomics of glycosaminoglycans (GAGs). Combined with enzymology, ESI MS is used for assessing changes in disaccharide composition of GAGs biosynthesized under different environmental or physiological conditions. ESI coupled with high-resolution mass analyzers such as a Fourier transform mass spectrometer (FTMS) permits accurate mass measurement of large oligosaccharides and intact GAGs as well as structural characterization of GAG oligosaccharides using information-rich fragmentation methods such as electron detachment dissociation. The first part of this chapter describes methods for disaccharide compositional profiling using ESI MS and the second part is dedicated to FTMS and tandem MS methods of GAG compositional and structural analysis. PMID:20816475

  15. Illustrating the Concepts of Isotopes and Mass Spectrometry in Introductory Courses: A MALDI-TOF Mass Spectrometry Laboratory Experiment

    ERIC Educational Resources Information Center

    Dopke, Nancy Carter; Lovett, Timothy Neal

    2007-01-01

    Mass spectrometry is a widely used and versatile tool for scientists in many different fields. Soft ionization techniques such as matrix-assisted laser desorption/ionization (MALDI) allow for the analysis of biomolecules, polymers, and clusters. This article describes a MALDI mass spectrometry experiment designed for students in introductory…

  16. Accurate on-line mass flow measurements in supercritical fluid chromatography.

    PubMed

    Tarafder, Abhijit; Vajda, Péter; Guiochon, Georges

    2013-12-13

    This work demonstrates the possible advantages and the challenges of accurate on-line measurements of the CO2 mass flow rate during supercritical fluid chromatography (SFC) operations. Only the mass flow rate is constant along the column in SFC. The volume flow rate is not. The critical importance of accurate measurements of mass flow rates for the achievement of reproducible data and the serious difficulties encountered in supercritical fluid chromatography for its assessment were discussed earlier based on the physical properties of carbon dioxide. In this report, we experimentally demonstrate the problems encountered when performing mass flow rate measurements and the gain that can possibly be achieved by acquiring reproducible data using a Coriolis flow meter. The results obtained show how the use of a highly accurate mass flow meter permits, besides the determination of accurate values of the mass flow rate, a systematic, constant diagnosis of the correct operation of the instrument and the monitoring of the condition of the carbon dioxide pump. PMID:24210558

  17. Identification of Unknown Contaminants in Water Samples from ISS Employing Liquid Chromatography/Mass Spectrometry/Mass Spectrometry

    NASA Technical Reports Server (NTRS)

    Rutz, Jeffrey A.; Schultz, John R.

    2008-01-01

    Mass Spectrometry/Mass Spectrometry (MS/MS) is a powerful technique for identifying unknown organic compounds. For non-volatile or thermally unstable unknowns dissolved in liquids, liquid chromatography/mass spectrometry/mass spectrometry (LC/MS/MS) is often the variety of MS/MS used for the identification. One type of LC/MS/MS that is rapidly becoming popular is time-of-flight (TOF) mass spectrometry. This technique is now in use at the Johnson Space Center for identification of unknown nonvolatile organics in water samples from the space program. An example of the successful identification of one unknown is reviewed in detail in this paper. The advantages of time-of-flight instrumentation are demonstrated through this example as well as the strategy employed in using time-of-flight data to identify unknowns.

  18. Signatures for Mass Spectrometry Data Quality

    PubMed Central

    2014-01-01

    Ensuring data quality and proper instrument functionality is a prerequisite for scientific investigation. Manual quality assurance is time-consuming and subjective. Metrics for describing liquid chromatography mass spectrometry (LC–MS) data have been developed; however, the wide variety of LC–MS instruments and configurations precludes applying a simple cutoff. Using 1150 manually classified quality control (QC) data sets, we trained logistic regression classification models to predict whether a data set is in or out of control. Model parameters were optimized by minimizing a loss function that accounts for the trade-off between false positive and false negative errors. The classifier models detected bad data sets with high sensitivity while maintaining high specificity. Moreover, the composite classifier was dramatically more specific than single metrics. Finally, we evaluated the performance of the classifier on a separate validation set where it performed comparably to the results for the testing/training data sets. By presenting the methods and software used to create the classifier, other groups can create a classifier for their specific QC regimen, which is highly variable lab-to-lab. In total, this manuscript presents 3400 LC–MS data sets for the same QC sample (whole cell lysate of Shewanella oneidensis), deposited to the ProteomeXchange with identifiers PXD000320–PXD000324. PMID:24611607

  19. Laser-induced electron capture mass spectrometry

    PubMed

    Wang; Giese

    2000-02-15

    Two techniques are reported for detection of electrophorederivatized compounds by laser-induced electron capture time-of-flight mass spectrometry (LI-EC-TOF-MS). In both cases, a nitrogen laser is used to induce the electron capture. The analyte is deposited in a matrix consisting of a compound with a low ionization potential such as benzo[ghi]perylene in the first technique, where the electron for electron capture apparently comes from this matrix. In the second technique, the analyte is deposited on a silver surface in the absence of matrix. It seems that "monoenergetic" ions instantly desorb from the target surface in the latter case, since the peak width in the continuous extraction mode essentially matches the pulse width of the laser (4 ns). Ten picomoles of 3-O-(pentafluorobenzyl)-alpha-estradiol were detected at a S/N > or = 50, where the spot size of the laser was approximately 0.25% of the sample spot. It is attractive that simple conditions can enable sensitive detection of electrophores on routine TOF-MS equipment. The technique can be anticipated to broaden the range of analytes in both polarity and size that can be detected by EC-MS relative to the range for GC/EC-MS. PMID:10701262

  20. Secondary Ion Mass Spectrometry SIMS XI

    NASA Astrophysics Data System (ADS)

    Gillen, G.; Lareau, R.; Bennett, J.; Stevie, F.

    2003-05-01

    This volume contains 252 contributions presented as plenary, invited and contributed poster and oral presentations at the 11th International Conference on Secondary Ion Mass Spectrometry (SIMS XI) held at the Hilton Hotel, Walt Disney World Village, Orlando, Florida, 7 12 September, 1997. The book covers a diverse range of research, reflecting the rapid growth in advanced semiconductor characterization, ultra shallow depth profiling, TOF-SIMS and the new areas in which SIMS techniques are being used, for example in biological sciences and organic surface characterization. Papers are presented under the following categories: Isotopic SIMS Biological SIMS Semiconductor Characterization Techniques and Applications Ultra Shallow Depth Profiling Depth Profiling Fundamental/Modelling and Diffusion Sputter-Induced Topography Fundamentals of Molecular Desorption Organic Materials Practical TOF-SIMS Polyatomic Primary Ions Materials/Surface Analysis Postionization Instrumentation Geological SIMS Imaging Fundamentals of Sputtering Ion Formation and Cluster Formation Quantitative Analysis Environmental/Particle Characterization Related Techniques These proceedings provide an invaluable source of reference for both newcomers to the field and experienced SIMS users.

  1. MSSimulator: Simulation of mass spectrometry data.

    PubMed

    Bielow, Chris; Aiche, Stephan; Andreotti, Sandro; Reinert, Knut

    2011-07-01

    Mass spectrometry coupled to liquid chromatography (LC-MS and LC-MS/MS) is commonly used to analyze the protein content of biological samples in large scale studies, enabling quantitation and identification of proteins and peptides using a wide range of experimental protocols, algorithms, and statistical models to analyze the data. Currently it is difficult to compare the plethora of algorithms for these tasks. So far, curated benchmark data exists for peptide identification algorithms but data that represents a ground truth for the evaluation of LC-MS data is limited. Hence there have been attempts to simulate such data in a controlled fashion to evaluate and compare algorithms. We present MSSimulator, a simulation software for LC-MS and LC-MS/MS experiments. Starting from a list of proteins from a FASTA file, the simulation will perform in-silico digestion, retention time prediction, ionization filtering, and raw signal simulation (including MS/MS), while providing many options to change the properties of the resulting data like elution profile shape, resolution and sampling rate. Several protocols for SILAC, iTRAQ or MS(E) are available, in addition to the usual label-free approach, making MSSimulator the most comprehensive simulator for LC-MS and LC-MS/MS data. PMID:21526843

  2. Mass Spectrometry of Nanoparticles is Different

    NASA Astrophysics Data System (ADS)

    Liang, C.-K.; Eller, M. J.; Verkhoturov, S. V.; Schweikert, Emile A.

    2015-08-01

    Secondary ion mass spectrometry, SIMS, is a method of choice for the characterization of nanoparticles, NPs. For NPs with large surface-to-volume ratios, heterogeneity is a concern. Assays should thus be on individual nano-objects rather than an ensemble of NPs; however, this may be difficult or impossible. This limitation can be side-stepped by probing a large number of dispersed NPs one-by-one and recording the emission from each NP separately. A large collection of NPs will likely contain subsets of like-NPs. The experimental approach is to disperse the NPs and hit an individual NP with a single massive cluster (e.g., C-60, Au-400). At impact energies of ~1 keV/atom, they generate notable secondary ion (SI) emission. Examination of small NPs (≤20 nm in diameter) shows that the SI emission is size-dependent and impacts are not all equivalent. Accurate identification of the type of impact is key for qualitative assays of core or outer shell composition. For quantitative assays, the concept of effective impacts is introduced. Selection of co-emitted ejecta combined with rejection (anticoincidence) of substrate ions allows refining chemical information within the projectile interaction volume. Last, to maximize the SI signal, small NPs (≤5 nm in diameter) can be examined in the transmission mode where the SI yields are enhanced ~10-fold over those in the (conventional) reflection direction. Future endeavors should focus on schemes acquiring SIs, electrons, and photons concurrently.

  3. Cytotoxicity Test and Mass Spectrometry of IPMC

    NASA Astrophysics Data System (ADS)

    Takashima, Kazuto; Kamamichi, Norihiro; Yagi, Tohru; Asaka, Kinji; Mukai, Toshiharu

    Ionic polymer-metal composite (IPMC) is a promising material in biomedical actuators and sensors because IPMC is soft and flexible, leading to the safety of the device itself. The purpose of this study is to investigate the biocompatibility of IPMC by in vitro experiments, in order to evaluate the applicability in biomedical fields. In addition to an IPMC specimen prepared by the conventional “impregnation-reduction method” using cationic gold complexes and reducing agents, two specimens were prepared by processes in addition to that used for the conventional IPMC specimen. One specimen was reduced in Na2SO3 solution and another specimen was cleaned in H2O2 solution. Colony-forming test using Chinese hamster V79 cells shows high cytotoxicity of all IPMC specimens. Examination of direct inlet mass spectrometry (DI-MS) revealed that the peak intensity of gold complex (particularly, m/z=180) was different from that of Nafion film. Monitoring the peak at m/z=180 showed a remnant with the structure of phenanthroline in IPMC specimens which were not cleaned in H2O2 solution.

  4. Mass spectrometry of atmospheric pressure plasmas

    NASA Astrophysics Data System (ADS)

    Große-Kreul, S.; Hübner, S.; Schneider, S.; Ellerweg, D.; von Keudell, A.; Matejčík, S.; Benedikt, J.

    2015-08-01

    Atmospheric pressure non-equilibrium plasmas (APPs) are effective source of radicals, metastables and a variety of ions and photons, ranging into the vacuum UV spectral region. A detailed study of these species is important to understand and tune desired effects during the interaction of APPs with solid or liquid materials in industrial or medical applications. In this contribution, the opportunities and challenges of mass spectrometry for detection of neutrals and ions from APPs, fundamental physical phenomena related to the sampling process and their impact on the measured densities of neutrals and fluxes of ions, will be discussed. It is shown that the measurement of stable neutrals and radicals requires a proper experimental design to reduce the beam-to-background ratio, to have little beam distortion during expansion into vacuum and to carefully set the electron energy in the ionizer to avoid radical formation through dissociative ionization. The measured ion composition depends sensitively on the degree of impurities present in the feed gas as well as on the setting of the ion optics used for extraction of ions from the expanding neutral-ion mixture. The determination of the ion energy is presented as a method to show that the analyzed ions are originating from the atmospheric pressure plasma.

  5. Femtosecond laser ablation elemental mass spectrometry.

    PubMed

    Hergenröder, Roland; Samek, Ota; Hommes, Vanja

    2006-01-01

    Laser ablation mass spectrometry (LA-MS) has always been an interesting method for the elemental analysis of solid samples. Chemical analysis with a laser requires small amounts of material. Depending on the analytical detection system, subpicogram quantities may be sufficient. In addition, a focused laser beam permits the spatial characterization of heterogeneity in solid samples typically with micrometer resolution in terms of lateral and depth dimensions. With the advent of high-energy, ultra-short pulse lasers, new possibilities arise. The task of this review is to discuss the principle differences between the ablation process of short (>1 ps) and ultra-short (<1 ps) pulses. Based on the timescales and the energy balance of the process that underlies an ablation event, it will be shown that ultra-short pulses are less thermal and cause less collateral damages than longer pulses. The confinement of the pulse energy to the focal region guarantees a better spatial resolution in all dimensions and improves the analytical figures of merit (e.g., fractionation). Applications that demonstrate these features and that will be presented are in-depth profiling of multi-layer samples and the elemental analysis of biological materials. PMID:16477613

  6. Detection of Gunshot Residues Using Mass Spectrometry

    PubMed Central

    Blanes, Lucas; Cole, Nerida; Doble, Philip; Roux, Claude

    2014-01-01

    In recent years, forensic scientists have become increasingly interested in the detection and interpretation of organic gunshot residues (OGSR) due to the increasing use of lead- and heavy metal-free ammunition. This has also been prompted by the identification of gunshot residue- (GSR-) like particles in environmental and occupational samples. Various techniques have been investigated for their ability to detect OGSR. Mass spectrometry (MS) coupled to a chromatographic system is a powerful tool due to its high selectivity and sensitivity. Further, modern MS instruments can detect and identify a number of explosives and additives which may require different ionization techniques. Finally, MS has been applied to the analysis of both OGSR and inorganic gunshot residue (IGSR), although the “gold standard” for analysis is scanning electron microscopy with energy dispersive X-ray microscopy (SEM-EDX). This review presents an overview of the technical attributes of currently available MS and ionization techniques and their reported applications to GSR analysis. PMID:24977168

  7. Tandem mass spectrometry: analysis of complex mixtures

    SciTech Connect

    Singleton, K.E.

    1985-01-01

    Applications of tandem mass spectrometry (MS/MS) for the analysis of complex mixtures results in increased specificity and selectivity by using a variety of reagent gases in both negative and positive ion modes. Natural isotopic abundance ratios were examined in both simple and complex mixtures using parent, daughter and neutral loss scans. MS/MS was also used to discover new compounds. Daughter scans were used to identify seven new alkaloids in a cactus species. Three of these alkaloids were novel compounds, and included the first simple, fully aromatic isoquinoline alkaloids reported in Cactaceae. MS/MS was used to characterize the chemical reaction products of coal in studies designed to probe its macromolecular structure. Negative ion chemical ionization was utilized to study reaction products resulting from the oxidation of coal. Possible structural units in the precursor coal were predicted based on the reaction products identified, aliphatic and aromatic acids and their anhydrides. The MS/MS method was also used to characterize reaction products resulting from coal liquefaction and/or extraction. These studies illustrate the types of problems for which MS/MS is useful. Emphasis has been placed on characterization of complex mixtures by selecting experimental parameters which enhance the information obtained. The value of using MS/MS in conjunction with other analytical techniques as well as the chemical pretreatment is demonstrated.

  8. Accelerator Mass Spectrometry in Laboratory Nuclear Astrophysics

    NASA Astrophysics Data System (ADS)

    Nusair, O.; Bauder, W.; Gyürky, G.; Paul, M.; Collon, P.; Fülöp, Zs; Greene, J.; Kinoshita, N.; Palchan, T.; Pardo, R.; Rehm, K. E.; Scott, R.; Vondrasek, R.

    2016-01-01

    The extreme sensitivity and discrimination power of accelerator mass spectrometry (AMS) allows for the search and the detection of rare nuclides either in natural samples or produced in the laboratory. At Argonne National Laboratory, we are developing an AMS setup aimed in particular at the detection of medium and heavy nuclides, relying on the high ion energy achievable with the ATLAS superconducting linear accelerator and on gas-filled magnet isobaric separation. The setup was recently used for the detection of the 146Sm p-process nuclide and for a new determination of the 146Sm half-life (68.7 My). AMS plays an important role in the measurement of stellar nuclear reaction cross sections by the activation method, extending thus the technique to the study of production of long-lived radionuclides. Preliminary measurements of the 147Sm(γ,n)146Sm are described. A measurement of the 142Nd(α,γ)146Sm and 142Nd(α,n)145Sm reactions is in preparation. A new laser-ablation method for the feeding of the Electron Cyclotron Resonance (ECR) ion source is described.

  9. Mass spectrometry of Natural Products: Current, Emerging and Future Technologies

    PubMed Central

    Bouslimani, Amina; Sanchez, Laura M; Garg, Neha; Dorrestein, Pieter C

    2014-01-01

    Although mass spectrometry is a century old technology, we are entering into an exciting time for the analysis of molecular information directly from complex biological systems. In this viewpoint article, we highlight emerging mass spectrometric methods and tools used by the natural product community and give a perspective of future directions where the mass spectrometry field is migrating towards over the next decade. PMID:24801551

  10. Imaging mass spectrometry in biological tissues by laser ablation inductively coupled plasma mass spectrometry.

    PubMed

    Becker, J S; Becker, J Su; Zoriy, M V; Dobrowolska, J; Matucsh, A

    2007-01-01

    Of all the inorganic mass spectrometric techniques, laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) plays a key role as a powerful and sensitive microanalytical technique enabling multi- element trace analysis and isotope ratio measurements at trace and ultratrace level. LA-ICP-MS was used to produce images of detailed regionally-specific element distribution in 20 microm thin sections of different parts of the human brain. The quantitative determination of copper, zinc, lead and uranium distribution in thin slices of human brain samples was performed using matrix-matched laboratory standards via external calibration procedures. Imaging mass spectrometry provides new information on the spatially inhomogeneous element distribution in thin sections of human tissues, for example, of different brain regions (the insular region) or brain tumor tissues. The detection limits obtained for Cu, Zn, Pb and U were in the ng g(-1) range. Possible strategies of LA-ICP-MS in brain research and life sciences include the elemental imaging of thin slices of brain tissue or applications in proteome analysis by combination with matrix-assisted laser desorption/ionization MS to study phospho- and metal- containing proteins will be discussed. PMID:17885277

  11. Determination of sulfonamides by packed column supercritical fluid chromatography with atmospheric pressure chemical ionisation mass spectrometric detection.

    PubMed

    Dost, K; Jones, D C; Davidson, G

    2000-07-01

    Sulfonamide antibiotics are widely used to prevent bacterial infections in livestock, and residues are commonly found in milk and meat. Packed column supercritical fluid chromatography (pSFC) with detection using ultra violet (UV) and atmospheric pressure chemical ionisation (APCI) mass spectrometry (MS) provides a versatile method for the detection and quantification of six major sulfonamides. The APCI mass spectra for all the sulfonamides consisted of protonated molecules at low cone voltages. Increasing the cone voltage led to informative fragmentation patterns, which provided structural information for identification purposes. The pSFC-APCI-MS technique was shown to be linear (r2 > or = 0.999) over the concentration range 0.1-50 micrograms ml-1 using total ion current. The precision and the accuracy of the system and validation of sample preparation are acceptable, with RSD < 2% and relative error 8%. Selected ion monitoring gave detection limits as follows: sulfadiazine 41, sulfamethoxazole 45, sulfamerazine 47, sulfamethizole 59, sulfamethazine 181 and sulfadimethoxine 96 micrograms l-1, which are lower than the amounts permitted in milk products. The APCI pSFC-MS system was shown to have a high degree of reproducibility. The technique was then applied to determine the above sulfonamides in milk. The results obtained show that there are no matrix effects from the milk and that the detection limits remained as stated for the standard solutions. PMID:10984919

  12. Mass transfer enhancement in supercritical fluids extraction by means of power ultrasound.

    PubMed

    Riera, E; Golás, Y; Blanco, A; Gallego, J A; Blasco, M; Mulet, A

    2004-05-01

    The use of high-intensity ultrasound represents an efficient manner of producing small scale agitation, enhancing mass transfer on supercritical fluids (SF) extraction processes. In this way, a supercritical CO(2) extraction of oil from particulate almonds using power ultrasound was studied. To examine the effect of the acoustic waves all experiments were performed with and without ultrasound. A power ultrasonic transducer for a working frequency of about 20 kHz was constructed and installed inside a high-pressure 5 l SF extractor. The experimental tests were carried out with CO(2) at 280 bar and 55 degrees C. Grounded almonds with an oil content of about 55%, in an amount of 1500 g were deposited inside the SF reactor where the solvent was introduced at a flow rate of 20 kg/h. The results show that the kinetics and the extraction yield of the oil were enhanced by 30% and 20% respectively, when a power of about 50 W was applied to the transducer. The average time of each extraction process was of about 8 h and 30 min. In addition, the transducer was also used as a sensitive probe capable to detect the phase behavior of supercritical fluids when it was driven with low power signals. PMID:15081988

  13. Membrane introduction mass spectrometry: trends and applications.

    PubMed

    Johnson, R C; Cooks, R G; Allen, T M; Cisper, M E; Hemberger, P H

    2000-01-01

    Recent advances in membrane introduction mass spectrometry (MIMS) are reviewed. On-line monitoring is treated by focusing on critical variables, including the nature and dimensions of the membrane, and the analyte vapor pressure, diffusivity, and solubility in the membrane barrier. Sample introduction by MIMS is applied in (i) on-line monitoring of chemical and biological reactors, (ii) analysis of volatile organic compounds in environmental matrices, including air, water and soil, and (iii) in more fundamental studies, such as measurements of thermochemical properties, reaction mechanisms, and kinetics. New semipermeable membranes are discussed, including those consisting of thin polymers, low vapor pressure liquids, and zeolites. These membranes have been used to monitor polar compounds, selectively differentiate compounds through affinity-binding, and provide isomer differentiation based on molecular size. Measurements at high spatial resolution, for example, using silicone-capped hypodermic needle inlets, are also covered, as is electrically driven sampling through microporous membranes. Other variations on the basic MIMS experiment include analyte preconcentration through cryotrapping (CT-MIMS) or trapping in the membrane (trap-and-release), as well as differential thermal release methods and reverse phase (i.e., organic solvent) MIMS. Method limitations center on semivolatile compounds and complex mixture analysis, and novel solutions are discussed. Semivolatile compounds have been monitored with thermally assisted desorption, ultrathin membranes and derivatization techniques. Taking advantage of the differences in time of membrane permeation, mixtures of structurally similar compounds have been differentiated by using sample modulation techniques and by temperature-programmed desorption from a membrane interface. Selective ionization techniques that increase instrument sensitivity towards polar compounds are also described, and comparisons are made with

  14. Foreword: Collision and reaction cell techniques in atomic mass spectrometry

    SciTech Connect

    Koppenaal, David W.; Eiden, Greg C.

    2004-01-01

    This contribution is a guest editorial statement and technical assessment for a special issue of the Royal Society of Chemistry journal entitled Journal of Analytical Atomic Spectrometry (JAAS). The editorial introduces the subject area of collision and reaction cells in atomic mass spectrometry, reviews current literature and commercial instrumentation trends, and previews four perspective and numerous research articles contained in the special journal issue.

  15. Electron Transfer Dissociation Mass Spectrometry of Hemoglobin on Clinical Samples

    NASA Astrophysics Data System (ADS)

    Coelho Graça, Didia; Lescuyer, Pierre; Clerici, Lorella; Tsybin, Yury O.; Hartmer, Ralf; Meyer, Markus; Samii, Kaveh; Hochstrasser, Denis F.; Scherl, Alexander

    2012-10-01

    A mass spectrometry-based assay combining the specificity of selected reaction monitoring and the protein ion activation capabilities of electron transfer dissociation was developed and employed for the rapid identification of hemoglobin variants from whole blood without previous proteolytic cleavage. The analysis was performed in a robust ion trap mass spectrometer operating at nominal mass accuracy and resolution. Subtle differences in globin sequences, resulting with mass shifts of about one Da, can be unambiguously identified. These results suggest that mass spectrometry analysis of entire proteins using electron transfer dissociation can be employed on clinical samples in a workflow compatible with diagnostic applications.

  16. Applications of Hadamard transform to gas chromatography/mass spectrometry and liquid chromatography/mass spectrometry.

    PubMed

    Lin, Cheng-Huang; Kaneta, Takashi; Chen, Hung-Ming; Chen, Wen-Xiong; Chang, Hung-Wei; Liu, Ju-Tsung

    2008-08-01

    Successful application of the Hadamard transform (HT) technique to gas chromatography/mass spectrometry (GC/MS) and liquid chromatography/mass spectrometry (LC/MS) is described. Novel sample injection devices were developed to achieve multiple sample injections in both GC and LC instruments. Air pressure was controlled by an electromagnetic valve in GC, while a syringe pump and Tee connector were employed for the injection device in LC. Two well-known, abused drugs, 3,4-methylenedioxy-N-methylamphetamine (MDMA) and N, N-dimethyltryptamine (DMT), were employed as model samples. Both of the injection devices permitted precise successive injections, resulting in clearly modulated chromatograms encoded by Hadamard matrices. After inverse Hadamard transformation of the encoded chromatogram, the signal-to-noise (S/N) ratios of the signals were substantially improved compared with those expected from theoretical values. The S/N ratios were enhanced approximately 10-fold in HT-GC/MS and 6.8 in HT-LC/MS, using the matrices of 1023 and 511, respectively. The HT-GC/MS was successfully applied to the determination of MDMA in the urine sample of a suspect. PMID:18570388

  17. Ambient mass spectrometry imaging: plasma assisted laser desorption ionization mass spectrometry imaging and its applications.

    PubMed

    Feng, Baosheng; Zhang, Jialing; Chang, Cuilan; Li, Liping; Li, Min; Xiong, Xingchuang; Guo, Chengan; Tang, Fei; Bai, Yu; Liu, Huwei

    2014-05-01

    Mass spectrometry imaging (MSI) has been widely used in many research areas for the advantages of providing informative molecular distribution with high specificity. Among the recent progress, ambient MSI has attracted increasing interests owing to its characteristics of ambient, in situ, and nonpretreatment analysis. Here, we are presenting the ambient MSI for traditional Chinese medicines (TCMs) and authentication of work of art and documents using plasma assisted laser desorption ionization mass spectrometry (PALDI-MS). Compared with current ambient MSI methods, an excellent average resolution of 60 μm × 60 μm pixel size was achieved using this system. The feasibility of PALDI-based MSI was confirmed by seal imaging, and its authentication applications were demonstrated by imaging of printed Chinese characters. Imaging of the Radix Scutellariae slice showed that the two active components, baicalein and wogonin, mainly were distributed in the epidermis of the root, which proposed an approach for distinguishing TCMs' origins and the distribution of active components of TCMs and exploring the environmental effects of plant growth. PALDI-MS imaging provides a strong complement for the MSI strategy with the enhanced spatial resolution, which is promising in many research fields, such as artwork identification, TCMs' and botanic research, pharmaceutical applications, etc. PMID:24670045

  18. imzML: Imaging Mass Spectrometry Markup Language: A common data format for mass spectrometry imaging.

    PubMed

    Römpp, Andreas; Schramm, Thorsten; Hester, Alfons; Klinkert, Ivo; Both, Jean-Pierre; Heeren, Ron M A; Stöckli, Markus; Spengler, Bernhard

    2011-01-01

    Imaging mass spectrometry is the method of scanning a sample of interest and generating an "image" of the intensity distribution of a specific analyte. The data sets consist of a large number of mass spectra which are usually acquired with identical settings. Existing data formats are not sufficient to describe an MS imaging experiment completely. The data format imzML was developed to allow the flexible and efficient exchange of MS imaging data between different instruments and data analysis software.For this purpose, the MS imaging data is divided in two separate files. The mass spectral data is stored in a binary file to ensure efficient storage. All metadata (e.g., instrumental parameters, sample details) are stored in an XML file which is based on the standard data format mzML developed by HUPO-PSI. The original mzML controlled vocabulary was extended to include specific parameters of imaging mass spectrometry (such as x/y position and spatial resolution). The two files (XML and binary) are connected by offset values in the XML file and are unambiguously linked by a universally unique identifier. The resulting datasets are comparable in size to the raw data and the separate metadata file allows flexible handling of large datasets.Several imaging MS software tools already support imzML. This allows choosing from a (growing) number of processing tools. One is no longer limited to proprietary software, but is able to use the processing software which is best suited for a specific question or application. On the other hand, measurements from different instruments can be compared within one software application using identical settings for data processing. All necessary information for evaluating and implementing imzML can be found at http://www.imzML.org . PMID:21063949

  19. Application of Lithium Attachment Mass Spectrometry for Knudsen Evaporation and Chemical Ionisation Mass Spectrometry (KEMS, CIMS)

    NASA Astrophysics Data System (ADS)

    Bannan, T.; Booth, M.; Benyezzar, M.; Bacak, A.; Alfarra, M. R. R.; Topping, D. O.; Percival, C.

    2015-12-01

    Lithium ion attachment mass spectrometry provides a non-specific, non-fragmenting and sensitive method for detection of volatile species in the gas phase. The design, manufacture, and results from lithium ion attachment ionisation sources for two mass spectrometry systems are presented. Trace gas analysis is investigated using a modified Chemical Ionization Mass Spectrometer (CIMS) and vapour pressure (VP) measurements using a modified Knudsen Effusion Mass Spectrometer (KEMS) are presented. The Li+ modified CIMS provided limits of detection of 4 ppt for acetone, 0.2 ppt for formic acid, 15 ppt for nitric acid and 120 ppt from ammonia. Despite improvements, the problem of burnout remained persistent. The Li+ CIMS would unlikely be suitable for field or aircraft work, but could be appropriate for certain lab applications. The KEMS currently utilizes an electron impact (EI) ionisation source which provides a highly sensitive source, with the drawback of fragmentation of ionized molecules (Booth et al., 2009). Using Li+ KEMS the VP of samples can be measured without fragmentation and can therefore be used to identify VPs of individual components in mixtures. The validity of using Li+ for determining the VP of mixtures was tested by making single component VP measurements, which showed good agreement with EI measurements of Poly ethylene glycol (PEG) 3 and PEG 4, both when individually measured and when mixed. The Li+ KEMS was then used to investigate a system of atmospheric relevance, α-pinene secondary organic aerosol, generated in a reaction chamber (Alfarra et al., 2012). The VPs of the individual components from this generated sample are within the range we expect for compounds capable of partitioning between the particle and gas phase of an aerosol (0.1-10-5 Pa). Li+ source has a calculated sensitivity approximately 75 times less than that of EI, but the lack of fragmentation using the Li+ source is a significant advantage.

  20. Application of Lithium Attachment Mass Spectrometry for Knudsen Evaporation and Chemical Ionisation Mass Spectrometry (KEMS, CIMS)

    NASA Astrophysics Data System (ADS)

    Bannan, Thomas; Booth, A. Murray; Alfarra, Rami; Bacak, Asan; Pericval, Carl

    2016-04-01

    Lithium ion attachment mass spectrometry provides a non-specific, non-fragmenting and sensitive method for detection of volatile species in the gas phase. The design, manufacture, and results from lithium ion attachment ionisation sources for two mass spectrometry systems are presented. Trace gas analysis is investigated using a modified Chemical Ionization Mass Spectrometer (CIMS) and vapour pressure (VP) measurements using a modified Knudsen Effusion Mass Spectrometer (KEMS) are presented. The Li+ modified CIMS provided limits of detection of 4 ppt for acetone, 0.2 ppt for formic acid, 15 ppt for nitric acid and 120 ppt from ammonia. Despite improvements, the problem of burnout remained persistent. The Li+ CIMS would unlikely be suitable for field or aircraft work, but could be appropriate for certain lab applications. The KEMS currently utilizes an electron impact (EI) ionisation source which provides a highly sensitive source, with the drawback of fragmentation of ionized molecules (Booth et al., 2009). Using Li+ KEMS the VP of samples can be measured without fragmentation and can therefore be used to identify VPs of individual components in mixtures. The validity of using Li+ for determining the VP of mixtures was tested by making single component VP measurements, which showed good agreement with EI measurements of Poly ethylene glycol (PEG) 3 and PEG 4, both when individually measured and when mixed. The Li+ KEMS was then used to investigate a system of atmospheric relevance, α-pinene secondary organic aerosol, generated in a reaction chamber (Alfarra et al., 2012). The VPs of the individual components from this generated sample are within the range we expect for compounds capable of partitioning between the particle and gas phase of an aerosol (0.1-10-5 Pa). Li+ source has a calculated sensitivity approximately 75 times less than that of EI, but the lack of fragmentation using the Li+ source is a significant advantage.

  1. DIRECT-DEPOSITION INFRARED SPECTROMETRY WITH GAS AND SUPERCRITICAL FLUID CHROMATOGRAPHY

    EPA Science Inventory

    A direct-deposition Fourier transform infrared (FT-IR) system has been evaluated for applicability to gas chromatography (GC) and supercritical fluid chromatography (SFC) of environmental analytes. A 100-um i.d. fused-silica transfer line was used for GC, and a 50-um transfer lin...

  2. The clinical utility of mass spectrometry based protein assays.

    PubMed

    Lassman, Michael E; McAvoy, Thomas; Chappell, Derek L; Lee, Anita Y; Zhao, Xuemei X; Laterza, Omar F

    2016-08-01

    Reports of mass spectrometry based assays for peptides and proteins have become increasingly common in the literature. The growing interest of mass spectrometry for use in clinical laboratories has been primarily driven by the inherent selectivity of the platform relative to more traditional platforms such as immunoassays. However, the adoption of mass spectrometry for peptide and protein analysis in the clinic has been relatively slow compared its adoption in non-clinical laboratories such as in biomarker discovery efforts or within laboratories that support pharmaceutical and academic research. Here, we review some of the successful reports of MS based assays for human proteins in multiple stages of assay research, and describe how and why the platform was employed in order to demonstrate where and when mass spectrometry based assays will have value in the future. PMID:27259466

  3. Laser mass spectrometry for DNA sequencing, disease diagnosis, and fingerprinting

    NASA Astrophysics Data System (ADS)

    Chen, C. H. Winston; Taranenko, N. I.; Zhu, Y. F.; Chung, C. N.; Allman, S. L.

    1997-05-01

    Since laser mass spectrometry has the potential for achieving very fast DNA analysis, we recently applied it to DNA sequencing, DNA typing for fingerprinting, and DNA screening for disease diagnosis. Two different approaches for sequencing DNA have been successfully demonstrated. One is to sequence DNA with DNA ladders produced from Sanger's enzymatic method. The other is to do direct sequencing without DNA ladders. The need for quick DNA typing for identification purposes is critical for forensic application. Our preliminary results indicate laser mass spectrometry can possible be used for rapid DNA fingerprinting applications at a much lower cost than gel electrophoresis. Population screening for certain genetic disease can be a very efficient step to reducing medical costs through prevention. Since laser mass spectrometry can provide very fast DNA analysis, we applied laser mass spectrometry to disease diagnosis. Clinical samples with both base deletion and point mutation have been tested with complete success.

  4. Quantification of hydroxyacetone and glycolaldehyde using chemical ionization mass spectrometry

    NASA Astrophysics Data System (ADS)

    Spencer, K. M.; Beaver, M. R.; St. Clair, J. M.; Crounse, J. D.; Paulot, F.; Wennberg, P. O.

    2011-08-01

    Chemical ionization mass spectrometry (CIMS) enables online, fast, in situ detection and quantification of hydroxyacetone and glycolaldehyde. Two different CIMS approaches are demonstrated employing the strengths of single quadrupole mass spectrometry and triple quadrupole (tandem) mass spectrometry. Both methods are capable of the measurement of hydroxyacetone, an analyte with minimal isobaric interferences. Tandem mass spectrometry provides direct separation of the isobaric compounds glycolaldehyde and acetic acid using distinct, collision-induced dissociation daughter ions. Measurement of hydroxyacetone and glycolaldehyde by these methods was demonstrated during the ARCTAS-CARB 2008 campaign and the BEARPEX 2009 campaign. Enhancement ratios of these compounds in ambient biomass burning plumes are reported for the ARCTAS-CARB campaign. BEARPEX observations are compared to simple photochemical box model predictions of biogenic volatile organic compound oxidation at the site.

  5. Recent applications of mass spectrometry in forensic toxicology

    NASA Astrophysics Data System (ADS)

    Foltz, Rodger L.

    1992-09-01

    This review encompasses applications of mass spectrometry reported during the years 1989, 1990 and 1991 for the analysis of cannabinoids, cocaine, opiates, amphetamines, lysergic acid diethylamide (LSD), and their metabolites in physiological specimens.

  6. The use of elemental mass spectrometry in phosphoproteomic applications.

    PubMed

    Maes, Evelyne; Tirez, Kristof; Baggerman, Geert; Valkenborg, Dirk; Schoofs, Liliane; Encinar, Jorge Ruiz; Mertens, Inge

    2016-01-01

    Reversible phosphorylation is one of the most important post-translational modifications in mammalian cells. Because this molecular switch is an important mechanism that diversifies and regulates proteins in cellular processes, knowledge about the extent and quantity of phosphorylation is very important to understand the complex cellular interplay. Although phosphoproteomics strategies are applied worldwide, they mainly include only molecular mass spectrometry (like MALDI or ESI)-based experiments. Although identification and relative quantification of phosphopeptides is straightforward with these techniques, absolute quantification is more complex and usually requires for specific isotopically phosphopeptide standards. However, the use of elemental mass spectrometry, and in particular inductively coupled plasma mass spectrometry (ICP-MS), in phosphoproteomics-based experiments, allow one to absolutely quantify phosphopeptides. Here, these phosphoproteomic applications with ICP-MS as elemental detector are reviewed. Pioneering work and recent developments in the field are both described. Additionally, the advantage of the parallel use of molecular and elemental mass spectrometry is stressed. PMID:25139451

  7. Laser mass spectrometry for DNA sequencing, disease diagnosis, and fingerprinting

    SciTech Connect

    Winston Chen, C.H.; Taranenko, N.I.; Zhu, Y.F.; Chung, C.N.; Allman, S.L.

    1997-03-01

    Since laser mass spectrometry has the potential for achieving very fast DNA analysis, the authors recently applied it to DNA sequencing, DNA typing for fingerprinting, and DNA screening for disease diagnosis. Two different approaches for sequencing DNA have been successfully demonstrated. One is to sequence DNA with DNA ladders produced from Snager`s enzymatic method. The other is to do direct sequencing without DNA ladders. The need for quick DNA typing for identification purposes is critical for forensic application. The preliminary results indicate laser mass spectrometry can possibly be used for rapid DNA fingerprinting applications at a much lower cost than gel electrophoresis. Population screening for certain genetic disease can be a very efficient step to reducing medical costs through prevention. Since laser mass spectrometry can provide very fast DNA analysis, the authors applied laser mass spectrometry to disease diagnosis. Clinical samples with both base deletion and point mutation have been tested with complete success.

  8. Environmental Mass Spectrometry: Emerging Contaminants and Current Issues (2010 Review)

    EPA Science Inventory

    This biennial review covers developments in environmental mass spectrometry for emerging environmental contaminants over the period of 2008-2009. A few significant references that appeared between January and February 2010 are also included. Analytical Chemistry’s current polic...

  9. Mass Spectrometry of Membrane Proteins: A Focus on Aquaporins

    PubMed Central

    Schey, Kevin L.; Grey, Angus C.; Nicklay, Joshua J.

    2015-01-01

    Membrane proteins are abundant, critically important biomolecules that conduct essential functions in all cells and are the targets of a significant number of therapeutic drugs. However, the analysis of their expression, modification, protein–protein interactions, and structure by mass spectrometry has lagged behind similar studies of soluble proteins. Here we review the limitations to analysis of integral membrane and membrane-associated proteins and highlight advances in sample preparation and mass spectrometry methods that have led to the successful analysis of this protein class. Advances in the analysis of membrane protein posttranslational modification, protein–protein interaction, protein structure, and tissue distributions by imaging mass spectrometry are discussed. Furthermore, we focus our discussion on the application of mass spectrometry for the analysis of aquaporins as a prototypical integral membrane protein and how advances in analytical methods have revealed new biological insights into the structure and function of this family of proteins. PMID:23394619

  10. Process for increasing ionic charge in mass spectrometry

    SciTech Connect

    McLuckey, Scott A; He, Min

    2009-06-23

    Processes and apparatus are described for the analysis of molecules or fragments thereof, which are capable of carrying multiple charges, by reacting the multiply charged molecules or fragments thereof with other ions using mass spectrometry.

  11. Photodissociation mass spectrometry: New tools for characterization of biological molecules

    PubMed Central

    Brodbelt, Jennifer S.

    2014-01-01

    Photodissociation mass spectrometry combines the ability to activate and fragment ions using photons with the sensitive detection of the resulting product ions by mass spectrometry. The resulting combination affords a versatile tool for characterization of biological molecules. The scope and breadth of photodissociation mass spectrometry have increased substantially over the past decade as new research groups have entered the field and developed a number of innovative applications that illustrate the ability of photodissociation to produce rich fragmentation patterns, to cleave bonds selectively, and to target specific molecules based on incorporation of chromophores. This review focuses on many of the key developments in photodissociation mass spectrometry over the past decade with a particular emphasis on its applications to biological molecules. PMID:24481009

  12. Molecular Beam Mass Spectrometry (MBMS) (Revised) (Fact Sheet)

    SciTech Connect

    Not Available

    2011-07-01

    This fact sheet provides information about Molecular Beam Mass Spectrometry (MBMS) capabilities and applications at NREL's National Bioenergy Center. NREL has six MBMS systems that researchers and industry partners can use to understand thermochemical biomass conversion and biomass composition recalcitrance.

  13. Desorption electrospray ionization-mass spectrometry of proteins

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Desorption electrospray ionization-mass spectrometry (DESI-MS) was evaluated for the detection of proteins ranging in molecular mass from 12 to 66 kDa. Proteins were uniformly deposited on a solid surface without pretreatment and analyzed with a DESI source coupled to a quadrupole ion trap mass spec...

  14. THE APPLICATION OF MASS SPECTROMETRY TO THE STUDY OF MICROORGANISMS

    EPA Science Inventory

    The purpose of this research project is to use state-of-the-art mass spectrometric techniques, such as electrospray ionization (ESI) and matrix assisted laser desorption ionization (MALDI) mass spectrometry (MS), to provide "protein mass fingerprinting" and protein sequencing i...

  15. Growing massive black holes through supercritical accretion of stellar-mass seeds

    NASA Astrophysics Data System (ADS)

    Lupi, A.; Haardt, F.; Dotti, M.; Fiacconi, D.; Mayer, L.; Madau, P.

    2016-03-01

    The rapid assembly of the massive black holes that power the luminous quasars observed at z ˜ 6-7 remains a puzzle. Various direct collapse models have been proposed to head-start black hole growth from initial seeds with masses ˜105 M⊙, which can then reach a billion solar mass while accreting at the Eddington limit. Here, we propose an alternative scenario based on radiatively inefficient supercritical accretion of stellar-mass holes embedded in the gaseous circumnuclear discs (CNDs) expected to exist in the cores of high-redshift galaxies. Our sub-pc resolution hydrodynamical simulations show that stellar-mass holes orbiting within the central 100 pc of the CND bind to very high density gas clumps that arise from the fragmentation of the surrounding gas. Owing to the large reservoir of dense cold gas available, a stellar-mass black hole allowed to grow at super-Eddington rates according to the `slim-disc' solution can increase its mass by three orders of magnitudes within a few million years. These findings are supported by simulations run with two different hydro codes, RAMSES based on the Adaptive Mesh Refinement technique and GIZMO based on a new Lagrangian Godunov-type method, and with similar, but not identical, sub-grid recipes for star formation, supernova feedback, black hole accretion and feedback. The low radiative efficiency of supercritical accretion flows are instrumental to the rapid mass growth of our black holes, as they imply modest radiative heating of the surrounding nuclear environment.

  16. Mass spectrometry-based imaging of metabolites and proteins.

    PubMed

    Peukert, Manuela; Becker, Michael; Matros, Andrea; Mock, Hans-Peter

    2014-01-01

    Imaging techniques based on mass spectrometry (MS) have become powerful approaches to decipher the spatial distribution of metabolites and proteins. MS imaging (MSI) mostly relies on matrix-assisted laser desorption/ionization coupled to MS detection, but desorption electrospray ionization is also frequently used. Here we describe our current protocols for MALDI-MSI of seed sections and for root tissue. Detailed procedures for cryo-sectioning, matrix application, image capture, mass spectrometry measurement and data analysis are given. PMID:24136526

  17. Subcellular analysis by laser ablation electrospray ionization mass spectrometry

    DOEpatents

    Vertes, Akos; Stolee, Jessica A; Shrestha, Bindesh

    2014-12-02

    In various embodiments, a method of laser ablation electrospray ionization mass spectrometry (LAESI-MS) may generally comprise micro-dissecting a cell comprising at least one of a cell wall and a cell membrane to expose at least one subcellular component therein, ablating the at least one subcellular component by an infrared laser pulse to form an ablation plume, intercepting the ablation plume by an electrospray plume to form ions, and detecting the ions by mass spectrometry.

  18. Determination of nitrofuran and chloramphenicol residues by high resolution mass spectrometry versus tandem quadrupole mass spectrometry.

    PubMed

    Kaufmann, A; Butcher, P; Maden, K; Walker, S; Widmer, M

    2015-03-01

    An ultra-high performance liquid chromatography based method, coupled to high resolution mass spectrometry (UHPLC-HRMS), was developed to permit the detection and quantification of various nitrofuran and chloramphenicol residues in a number of animal based food products. This method is based on the hydrolysis of covalently bound metabolites and derivatization with 2-nitrobenzaldehyde. Clean-up is achieved by a liquid/liquid and a reversed phase/solid phase extraction. Not only are the four conventional nitrofurans (nitrofurantoin, furazolidone, nitrofurazone and furaltadone) detected, but also nifursol, nitrovin and nifuroxazide. Furthermore, an underivatizable nitrofuran (nifurpirinol) and another banned drug (chloramphenicol) can be quantified as well. The compounds are detected in the form of their precursor ions, [M+H](+) and [M-H](-), respectively. The mass resolving power of 70,000 FWHM, and the applied mass window ensure sufficient selectivity and sensitivity. Confirmation is obtained by monitoring the HRMS resolved product ions which were derived from the unit-mass resolved precursor ions. The multiplexing capability of the utilized Orbitrap instrument provides not only highly selective, but also sensitive confirmatory signals. This method has been validated according to the CD 2002/657/EC for the following matrices: muscle, liver, kidney, fish, honey, eggs and milk. PMID:25682427

  19. Accelerator mass spectrometry analysis of aroma compound absorption in plastic packaging materials

    NASA Astrophysics Data System (ADS)

    Stenström, Kristina; Erlandsson, Bengt; Hellborg, Ragnar; Wiebert, Anders; Skog, Göran; Nielsen, Tim

    1994-05-01

    Absorption of aroma compounds in plastic packaging materials may affect the taste of the packaged food and it may also change the quality of the packaging material. A method to determine the aroma compound absorption in polymers by accelerator mass spectrometry (AMS) is being developed at the Lund Pelletron AMS facility. The high sensitivity of the AMS method makes it possible to study these phenomena under realistic conditions. As a first test low density polyethylene exposed to 14C-doped ethyl acetate is examined. After converting the polymer samples with the absorbed aroma compounds to graphite, the {14C }/{13C } ratio of the samples is measured by the AMS system and the degree of aroma compound absorption is established. The results are compared with those obtained by supercritical fluid extraction coupled to gas chromatography (SFE-GC).

  20. Water chemical ionization mass spectrometry of aldehydes, ketones esters, and carboxylic acids

    SciTech Connect

    Hawthorne, S.B.; Miller, D.J.

    1986-11-01

    Chemical ionization mass spectrometry (CI) of aliphatic and aromatic carbonyl compounds using water as the reagent gas provides intense pseudomolecular ions and class-specific fragmentation patterns that can be used to identify aliphatic aldehydes, ketones, carboxylic acids, and esters. The length of ester acyl and alkyl groups can easily be determined on the basis of loss of alcohols from the protonated parent. Water CI provides for an approximately 200:1 selectivity of carbonyl species over alkanes. No reagent ions are detected above 55 amu, allowing species as small as acetone, propanal, acetic acid, and methyl formate to be identified. When deuterate water was used as the reagent, only the carboxylic acids and ..beta..-diketones showed significant H/D exchange. The use of water CI to identify carbonyl compounds in a wastewater from the supercritical water extraction of lignite coal, in lemon oil, and in whiskey volatiles is discussed.

  1. NCBI Peptidome: a new repository for mass spectrometry proteomics data

    PubMed Central

    Ji, Li; Barrett, Tanya; Ayanbule, Oluwabukunmi; Troup, Dennis B.; Rudnev, Dmitry; Muertter, Rolf N.; Tomashevsky, Maxim; Soboleva, Alexandra; Slotta, Douglas J.

    2010-01-01

    Peptidome is a public repository that archives and freely distributes tandem mass spectrometry peptide and protein identification data generated by the scientific community. Data from all stages of a mass spectrometry experiment are captured, including original mass spectra files, experimental metadata and conclusion-level results. The submission process is facilitated through acceptance of data in commonly used open formats, and all submissions undergo syntactic validation and curation in an effort to uphold data integrity and quality. Peptidome is not restricted to specific organisms, instruments or experiment types; data from any tandem mass spectrometry experiment from any species are accepted. In addition to data storage, web-based interfaces are available to help users query, browse and explore individual peptides, proteins or entire Samples and Studies. Results are integrated and linked with other NCBI resources to ensure dissemination of the information beyond the mass spectroscopy proteomics community. Peptidome is freely accessible at http://www.ncbi.nlm.nih.gov/peptidome. PMID:19942688

  2. Secondary Ion Mass Spectrometry Imaging of Dictyostelium discoideum Aggregation Streams

    SciTech Connect

    Debord, J. Daniel; Smith, Donald F.; Anderton, Christopher R.; Heeren, Ronald M.; Pasa-Tolic, Ljiljana; Gomer, Richard H.; Fernandez-Lima, Francisco A.

    2014-06-09

    High resolution imaging mass spectrometry could become a valuable tool for cell and developmental biology, but both, high spatial and mass spectral resolution are needed to enable this. In this report, we employed Bi3 bombardment time-of-flight (Bi3 ToF-SIMS) and C60 bombardment Fourier transform ion cyclotron resonance secondary ion mass spectrometry (C60 FTICR-SIMS) to image Dictyostelium discoideum aggregation streams. Nearly 300 lipid species were identified from the aggregation streams. High resolution mass spectrometry imaging (FTICR-SIMS) enabled the generation of multiple molecular ion maps at the nominal mass level and provided good coverage for fatty acyls, prenol lipids, and sterol lipids. The comparison of Bi3 ToF-SIMS and C60 FTICR-SIMS suggested that while the first provides fast, high spatial resolution molecular ion images, the chemical complexity of biological samples warrants the use of high resolution analyzers for accurate ion identification.

  3. Mass spectrometry imaging and profiling of single cells

    PubMed Central

    Lanni, Eric J.; Rubakhin, Stanislav S.; Sweedler, Jonathan V.

    2012-01-01

    Mass spectrometry imaging and profiling of individual cells and subcellular structures provide unique analytical capabilities for biological and biomedical research, including determination of the biochemical heterogeneity of cellular populations and intracellular localization of pharmaceuticals. Two mass spectrometry technologies—secondary ion mass spectrometry (SIMS) and matrix assisted laser desorption ionization mass spectrometry (MALDI MS)—are most often used in micro-bioanalytical investigations. Recent advances in ion probe technologies have increased the dynamic range and sensitivity of analyte detection by SIMS, allowing two- and three-dimensional localization of analytes in a variety of cells. SIMS operating in the mass spectrometry imaging (MSI) mode can routinely reach spatial resolutions at the submicron level; therefore, it is frequently used in studies of the chemical composition of subcellular structures. MALDI MS offers a large mass range and high sensitivity of analyte detection. It has been successfully applied in a variety of single-cell and organelle profiling studies. Innovative instrumentation such as scanning microprobe MALDI and mass microscope spectrometers enable new subcellular MSI measurements. Other approaches for MS-based chemical imaging and profiling include those based on near-field laser ablation and inductively-coupled plasma MS analysis, which offer complementary capabilities for subcellular chemical imaging and profiling. PMID:22498881

  4. Analytical techniques in biomedical stable isotope applications: (isotope ratio) mass spectrometry or infrared spectrometry?

    PubMed

    Stellaard, Frans; Elzinga, Henk

    2005-12-01

    An overview is presented of biomedical applications of stable isotopes in general, but mainly focused on the activities of the Center for Liver, Digestive and Metabolic Diseases of the University Medical Center Groningen. The aims of metabolic studies in the areas of glucose, fat, cholesterol and protein metabolism are briefly explained, as well as the principle of breath testing and the techniques to study body composition and energy expenditure. Much attention is paid to the analytical considerations based upon metabolite concentrations, sample size restrictions, the availability of stable isotope labelled substrates and dose requirements in relation to compound-specific isotope analysis. The instrumental advantages and limitations of the generally used techniques gas chromatography/reaction/isotope ratio mass spectrometry and gas chromatography/mass spectrometry are described as well as the novelties of the recently commercialised liquid chromatography/combustion/isotope ratio mass spectrometry. The present use and future perspective of infrared (IR) spectrometry for clinical and biomedical stable isotope applications are reviewed. In this respect, the analytical demands on IR spectrometry are discussed to enable replacement of isotope ratio mass spectrometry by IR spectrometry, in particular, for the purpose of compound-specific isotope ratio analysis in biological matrices. PMID:16543190

  5. Schottky Mass Spectrometry on 152Sm Projectile Fragments*

    NASA Astrophysics Data System (ADS)

    Yan, X. L.; Litvinov, Yu. A.; Bosch, F.; Brandau, C.; Chen, L.; Geissel, H.; Knöbel, R.; Kozhuharov, C.; Kurcewicz, J.; Litvinov, S. A.; Münzenberg, G.; Nociforo, C.; Nolden, F.; Plass, W. R.; Sanjari, M. S.; Scheidenberger, C.; Steck, M.; Sun, B.; Tu, X. L.; Wang, M.; Weick, H.; Winckler, N.; Winkler, M.; Xu, H. S.; Zhang, Y. H.; Zhou, X. H.

    Direct mass measurements of neutron-deficient 152Sm projectile fragments were conducted at the FRS-ESR facility at GSI by employing the time-resolved Schottky Mass Spectrometry. 311 different nuclides were identified by means of their revolution frequencies. Charge-dependent systematic differences between the fitted mass values and the literature mass values are observed in the data analysis. The origin of this systematic deviation is still under discussion. The latest progress on the data analysis is presented.

  6. DETERMINATION OF ELEMENTAL COMPOSITIONS BY HIGH RESOLUTION MASS SPECTROMETRY WITHOUT MASS CALIBRANTS

    EPA Science Inventory

    Widely applicable mass calibrants, including perfluorokerosene, are available for gas-phase introduction of analytes ionized by electron impact (EI) prior to analysis using high resolution mass spectrometry. Unfortunately, no all-purpose calibrants are available for recently dev...

  7. Incorporating Biological Mass Spectrometry into Undergraduate Teaching Labs, Part 2: Peptide Identification via Molecular Mass Determination

    ERIC Educational Resources Information Center

    Arnquist, Isaac J.; Beussman, Douglas J.

    2009-01-01

    Mass spectrometry has become a routine analytical tool in the undergraduate curriculum in the form of GC-MS. While relatively few undergraduate programs have incorporated biological mass spectrometry into their programs, the importance of these techniques, as demonstrated by their recognition with the 2002 Nobel Prize, will hopefully lead to…

  8. A Developmental History of Polymer Mass Spectrometry

    ERIC Educational Resources Information Center

    Vergne, Matthew J.; Hercules, David M.; Lattimer, Robert P.

    2007-01-01

    The history of the development of mass spectroscopic methods used to characterize polymers is discussed. The continued improvements in methods and instrumentation will offer new and better ways for the mass spectral characterization of polymers and mass spectroscopy (MS) should be recognized as a complementary polymer characterization method along…

  9. NEGATIVE-ION MASS SPECTROMETRY OF SULFONYLUREA HERBICIDES

    EPA Science Inventory

    Sulfonylurea herbicides have been studied using neg-ion desorption chem.-ionization (DCI) mass spectrometry (MS) and DCI-MS/MS techniques. Both {M-H]- and M.- ions were obsd. in the DCI mass spectra. The collisonally activated dissocn. (CAD) spectra were characteristic of the str...

  10. Desorption electrospray ionization mass spectrometry of intact bacteria

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Desorption electrospray ionization (DESI) mass spectrometry (MS) was used to differentiate 7 bacterial species based on their measured DESI-mass spectral profile. Both Gram positive and Gram negative bacteria were tested and included Escherichia coli, Staphyloccocus aureus, Enterococcus sp., Bordete...

  11. Mass spectrometry and hyphenated instruments in food analysis

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Mass spectrometry (MS) has come a long way since the record of the first mass spectra of a simple low molecular weight substance by J.J. Thomson in 1912. Especially over the past decades, MS has been the subject of many developments. Particularly, the hyphenation of MS to gas chromatography (GC) a...

  12. Analysis of intact bacteria using rapid evaporative ionisation mass spectrometry.

    PubMed

    Strittmatter, Nicole; Jones, Emrys A; Veselkov, Kirill A; Rebec, Monica; Bundy, Jacob G; Takats, Zoltan

    2013-07-14

    An identification system for microorganisms based on recently developed rapid evaporative ionisation mass spectrometry (REIMS) is presented. Nine bacterial species cultured on various growth media were correctly identified to family-, genus-, and species-level based on their different mass spectral fingerprints using a cross-validated maximum margin criterion model. PMID:23736664

  13. Mass Spectrometry-Based Tissue Imaging of Small Molecules

    PubMed Central

    Ferguson, Carly N.; Fowler, Joseph W.M.; Waxer, Jonathan F.; Gatti, Richard A.; Loo, Joseph A.

    2014-01-01

    Mass spectrometry imaging (MSI) of tissue samples is a promising analytical tool that has quickly become associated with biomedical and pharmacokinetic studies. It eliminates several labor-intensive protocols associated with more classical imaging techniques, and provides accurate, histological data at a rapid pace. Because mass spectrometry is used as the readout, MSI can be applied to almost any molecule, especially those that are biologically relevant. Many examples of its utility in the study of peptides and proteins have been reported; here we discuss its value in the mass range of small molecules. We explore its success and potential in the analysis of lipids, medicinals, and metal-based compounds by featuring representative studies from mass spectrometry imaging laboratories around the globe. PMID:24952187

  14. Use of mass spectrometry for imaging metabolites in plants

    SciTech Connect

    Lee, Young-Jin; Perdian, David; Song, Zhihong; Yeung, Edward; Nikolau, Basil

    2012-03-27

    We discuss and illustrate recent advances that have been made to image the distribution of metabolites among cells and tissues of plants using different mass spectrometry technologies. These technologies include matrix-assisted laser desorption ionization, desorption electrospray ionization, and secondary ion mass spectrometry. These are relatively new technological applications of mass spectrometry and they are providing highly spatially resolved data concerning the cellular distribution of metabolites. We discuss the advantages and limitations of each of these mass spectrometric methods, and provide a description of the technical barriers that are currently limiting the technology to the level of single-cell resolution. However, we anticipate that advances in the next few years will increase the resolving power of the technology to provide unprecedented data on the distribution of metabolites at the subcellular level, which will increase our ability to decipher new knowledge concerning the spatial organization of metabolic processes in plants.

  15. Use of Mass spectrometry for imaging metabolites in plants

    SciTech Connect

    Lee, Young Jin; Perdian, David C.; Song, Zhihong; Yeung, Edward S.; Nikolau, Basil

    2012-03-27

    We discuss and illustrate recent advances that have been made to image the distribution of metabolites among cells and tissues of plants using different mass spectrometry technologies. These technologies include matrix-assisted laser desorption ionization, desorption electrospray ionization, and secondary ion mass spectrometry. These are relatively new technological applications of mass spectrometry and they are providing highly spatially resolved data concerning the cellular distribution of metabolites. We discuss the advantages and limitations of each of these mass spectrometric methods, and provide a description of the technical barriers that are currently limiting the technology to the level of single-cell resolution. However, we anticipate that advances in the next few years will increase the resolving power of the technology to provide unprecedented data on the distribution of metabolites at the subcellular level, which will increase our ability to decipher new knowledge concerning the spatial organization of metabolic processes in plants.

  16. Direct analysis of samples by mass spectrometry: From elements to bio-molecules using laser ablation inductively couple plasma mass spectrometry and laser desorption/ionization mass spectrometry

    SciTech Connect

    Perdian, David C.

    2009-01-01

    Mass spectrometric methods that are able to analyze solid samples or biological materials with little or no sample preparation are invaluable to science as well as society. Fundamental research that has discovered experimental and instrumental parameters that inhibit fractionation effects that occur during the quantification of elemental species in solid samples by laser ablation inductively coupled plasma mass spectrometry is described. Research that determines the effectiveness of novel laser desorption/ionization mass spectrometric methods for the molecular analysis of biological tissues at atmospheric pressure and at high spatial resolution is also described. A spatial resolution is achieved that is able to analyze samples at the single cell level.

  17. Modeling of mass transfer of Phospholipids in separation process with supercritical CO2 fluid by RBF artificial neural networks

    Technology Transfer Automated Retrieval System (TEKTRAN)

    An artificial Radial Basis Function (RBF) neural network model was developed for the prediction of mass transfer of the phospholipids from canola meal in supercritical CO2 fluid. The RBF kind of artificial neural networks (ANN) with orthogonal least squares (OLS) learning algorithm were used for mod...

  18. Laser electrospray mass spectrometry of adsorbed molecules at atmospheric pressure

    NASA Astrophysics Data System (ADS)

    Brady, John J.; Judge, Elizabeth J.; Simon, Kuriakose; Levis, Robert J.

    2010-02-01

    Atmospheric pressure mass analysis of solid phase biomolecules is performed using laser electrospray mass spectrometry (LEMS). A non-resonant femtosecond duration laser pulse vaporizes native samples at atmospheric pressure for subsequent electrospray ionization and transfer into a mass spectrometer. LEMS was used to detect a complex molecule (irinotecan HCl), a complex mixture (cold medicine formulation with active ingredients: acetaminophen, dextromethorphan HBr and doxylamine succinate), and a biological building block (deoxyguanosine) deposited on steel surfaces without a matrix molecule.

  19. Integrating Mass Spectrometry of Intact Protein Complexes into Structural Proteomics

    PubMed Central

    Hyung, Suk-Joon; Ruotolo, Brandon T.

    2013-01-01

    Summary Mass spectrometry analysis of intact protein complexes has emerged as an established technology for assessing the composition and connectivity within dynamic, heterogeneous multiprotein complexes at low concentrations and in the context of mixtures. As this technology continues to move forward, one of the main challenges is to integrate the information content of such intact protein complex measurements with other mass spectrometry approaches in structural biology. Methods such as H/D exchange, oxidative foot-printing, chemical cross-linking, affinity purification, and ion mobility separation add complementary information that allows access to every level of protein structure and organization. Here, we survey the structural information that can be retrieved by such experiments, demonstrate the applicability of integrative mass spectrometry approaches in structural proteomics, and look to the future to explore upcoming innovations in this rapidly-advancing area. PMID:22611037

  20. Laser desorption mass spectrometry for biomolecule detection and its applications

    NASA Astrophysics Data System (ADS)

    Winston Chen, C. H.; Sammartano, L. J.; Isola, N. R.; Allman, S. L.

    2001-08-01

    During the past few years, we developed and used laser desorption mass spectrometry for biomolecule detections. Matrix-assisted laser desorption/ionization (MALDI) was successfully used to detect DNA fragments with the size larger than 3000 base pairs. It was also successfully used to sequence DNA with both enzymatic and chemical degradation methods to produce DNA ladders. We also developed MALDI with fragmentation for direct DNA sequencing for short DNA probes. Since laser desorption mass spectrometry for DNA detection has the advantages of fast speed and no need of labeling, it has a great potential for molecular diagnosis for disease and person identification by DNA fingerprinting. We applied laser desorption mass spectrometry to succeed in the diagnosis of cystic fibrosis and several other nerve degenerative diseases such as Huntington's disease. We also succeeded in demonstrating DNA typing for forensic applications.

  1. Ion mobility–mass spectrometry for structural proteomics

    PubMed Central

    Zhong, Yueyang; Hyung, Suk-Joon; Ruotolo, Brandon T

    2012-01-01

    Ion mobility coupled to mass spectrometry has been an important tool in the fields of chemical physics and analytical chemistry for decades, but its potential for interrogating the structure of proteins and multiprotein complexes has only recently begun to be realized. Today, ion mobility– mass spectrometry is often applied to the structural elucidation of protein assemblies that have failed high-throughput crystallization or NMR spectroscopy screens. Here, we highlight the technology, approaches and data that have led to this dramatic shift in use, including emerging trends such as the integration of ion mobility–mass spectrometry data with more classical (e.g., ‘bottom-up’) proteomics approaches for the rapid structural characterization of protein networks. PMID:22292823

  2. Mass Spectrometry Analysis of Pseudomonas aeruginosa Treated with Azithromycin

    NASA Astrophysics Data System (ADS)

    Phelan, Vanessa V.; Fang, Jinshu; Dorrestein, Pieter C.

    2015-06-01

    In microbiology, changes in specialized metabolite production (cell-to-cell signaling metabolites, virulence factors, and natural products) are measured using phenotypic assays. However, advances in mass spectrometry-based techniques including imaging mass spectrometry (IMS) now allow researchers to directly visualize the production of specialized metabolites from microbial colony biofilms. In this study, a combination of IMS and liquid chromatography-tandem mass spectrometry (LC-MS/MS) was used to visualize the effect of the macrolide antibiotic azithromycin (AZM) on colony biofilms of Pseudomonas aeruginosa. Although previous research suggested that AZM may inhibit cell-to-cell signaling of P. aeruginosa and thereby reduce pathogenicity, we observed no clear decrease in specialized metabolite production.

  3. Mass Spectrometry Analysis of Pseudomonas aeruginosa Treated With Azithromycin

    PubMed Central

    Phelan, Vanessa V.; Fang, Jinshu; Dorrestein, Pieter C.

    2015-01-01

    In microbiology, changes in specialized metabolite production (cell-to-cell signaling metabolites, virulence factors and natural products) are measured using phenotypic assays. However, advances in mass spectrometry based techniques including imaging mass spectrometry (IMS) now allow researchers to directly visualize the production of specialized metabolites from microbial colony biofilms. In this study, a combination of IMS and liquid chromatography-tandem mass spectrometry (LC-MS/MS) was used to visualize the effect of the macrolide antibiotic azithromycin (AZM) on colony biofilms of Pseudomonas aeruginosa. While previous research suggested that AZM may inhibit cell-to-cell signaling of P. aeruginosa and thereby reducing pathogenicity, we observed no clear decrease in specialized metabolite production. PMID:25801585

  4. Automated protein-ligand interaction screening by mass spectrometry.

    PubMed

    Maple, Hannah J; Garlish, Rachel A; Rigau-Roca, Laura; Porter, John; Whitcombe, Ian; Prosser, Christine E; Kennedy, Jeff; Henry, Alistair J; Taylor, Richard J; Crump, Matthew P; Crosby, John

    2012-01-26

    Identifying protein-ligand binding interactions is a key step during early-stage drug discovery. Existing screening techniques are often associated with drawbacks such as low throughput, high sample consumption, and dynamic range limitations. The increasing use of fragment-based drug discovery (FBDD) demands that these techniques also detect very weak interactions (mM K(D) values). This paper presents the development and validation of a fully automated screen by mass spectrometry, capable of detecting fragment binding into the millimolar K(D) range. Low sample consumption, high throughput, and wide dynamic range make this a highly attractive, orthogonal approach. The method was applied to screen 157 compounds in 6 h against the anti-apoptotic protein target Bcl-x(L). Mass spectrometry results were validated using STD-NMR, HSQC-NMR, and ITC experiments. Agreement between techniques suggests that mass spectrometry offers a powerful, complementary approach for screening. PMID:22148839

  5. Laser desorption mass spectrometry for DNA analysis and sequencing

    SciTech Connect

    Chen, C.H.; Taranenko, N.I.; Tang, K.; Allman, S.L.

    1995-03-01

    Laser desorption mass spectrometry has been considered as a potential new method for fast DNA sequencing. Our approach is to use matrix-assisted laser desorption to produce parent ions of DNA segments and a time-of-flight mass spectrometer to identify the sizes of DNA segments. Thus, the approach is similar to gel electrophoresis sequencing using Sanger`s enzymatic method. However, gel, radioactive tagging, and dye labeling are not required. In addition, the sequencing process can possibly be finished within a few hundred microseconds instead of hours and days. In order to use mass spectrometry for fast DNA sequencing, the following three criteria need to be satisfied. They are (1) detection of large DNA segments, (2) sensitivity reaching the femtomole region, and (3) mass resolution good enough to separate DNA segments of a single nucleotide difference. It has been very difficult to detect large DNA segments by mass spectrometry before due to the fragile chemical properties of DNA and low detection sensitivity of DNA ions. We discovered several new matrices to increase the production of DNA ions. By innovative design of a mass spectrometer, we can increase the ion energy up to 45 KeV to enhance the detection sensitivity. Recently, we succeeded in detecting a DNA segment with 500 nucleotides. The sensitivity was 100 femtomole. Thus, we have fulfilled two key criteria for using mass spectrometry for fast DNA sequencing. The major effort in the near future is to improve the resolution. Different approaches are being pursued. When high resolution of mass spectrometry can be achieved and automation of sample preparation is developed, the sequencing speed to reach 500 megabases per year can be feasible.

  6. Microbeam titanium isotopic analysis by resonance ionization mass spectrometry

    SciTech Connect

    Spiegel, D.R.; Davis, A.M.; Clayton, R.N. . Enrico Fermi Inst.); Pellin, M.J.; Calaway, W.F.; Burnett, J.W.; Coon, S.R.; Young, C.E.; Gruen, D.M. )

    1991-01-01

    The importance of isotopic anomalies in refractory inclusions in meteorites is well established. Measurements of the anomalies using conventional mass spectrometry are often rendered difficult, however, by isobarically interfering isotopes: for example, {sup 48}Ti and {sup 48}Ca. Resonance ionization mass spectrometry (RIMS) can substantially reduce isobaric interferences in a number of systems. We have employed RIMS for the in situ detection of Ti atoms sputtered from pure Ti metal and from several terrestrial oxides containing both Ti and Ca. Tunable lasers were employed to resonantly ionize neutral Ti atoms. We have chosen Ti specifically because of the importance of Ti isotopic anomalies in cosmochemistry.

  7. Mass spectrometry and inhomogeneous ion optics

    NASA Technical Reports Server (NTRS)

    White, F. A.

    1973-01-01

    Work done in several areas to advance the state of the art of magnetic mass spectrometers is described. The calculations and data necessary for the design of inhomogeneous field mass spectrometers, and the calculation of ion trajectories through such fields are presented. The development and testing of solid state ion detection devices providing the capability of counting single ions is discussed. New techniques in the preparation and operation of thermal-ionization ion sources are described. Data obtained on the concentrations of copper in rainfall and uranium in air samples using the improved thermal ionization techniques are presented. The design of a closed system static mass spectrometer for isotopic analyses is discussed. A summary of instrumental aspects of a four-stage mass spectrometer comprising two electrostatic and two 90 deg. magnetic lenses with a 122-cm radius used to study the interaction of ions with solids is presented.

  8. Determination of water content using mass spectrometry

    NASA Technical Reports Server (NTRS)

    Wood, G. M.; Upchurch, B. T.; Hughes, D. B.

    1975-01-01

    Mass spectrometer is used to measure small quantities of water present in different materials. System has been applied in measuring water and gases desorbed from microcircuitry insulation, can also be used with foods, polymeric materials, and organic solvents.

  9. Tropopsheric Aerosol Chemistry via Aerosol Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Worsnop, Douglas

    2008-03-01

    A broad overview of size resolved aerosol chemistry in urban, rural and remote regions is evolving from deployment of aerosol mass spectrometers (AMS) throughout the northern hemisphere. Using thermal vaporization and electron impact ionization as universal detector of non-refractory inorganic and organic composition, the accumulation of AMS results represent a library of mass spectral signatures of aerosol chemistry. For organics in particular, mass spectral factor analysis provides a procedure for classifying (and simplifying) complex mixtures composed of the hundreds or thousands of individual compounds. Correlations with parallel gas and aerosol measurements (e.g. GC/MS, HNMR, FTIR) supply additional chemical information needed to interpret mass spectra. The challenge is to separate primary and secondary; anthropogenic, biogenic and biomass burning sources - and subsequent - transformations of aerosol chemistry and microphysics.

  10. Structurally selective imaging mass spectrometry by imaging ion mobility-mass spectrometry.

    PubMed

    McLean, John A; Fenn, Larissa S; Enders, Jeffrey R

    2010-01-01

    This chapter describes the utility of structurally based separations combined with imaging mass spectrometry (MS) by ion mobility-MS (IM-MS) approaches. The unique capabilities of combining rapid (mus-ms) IM separations with imaging MS are detailed for an audience ranging from new to potential practitioners in IM-MS technology. Importantly, imaging IM-MS provides the ability to rapidly separate and elucidate various types of endogenous and exogenous biomolecules (e.g., nucleotides, carbohydrates, peptides, and lipids), including isobaric species. Drift tube and traveling wave IM-MS instrumentation are described and specific protocols are presented for calculating ion-neutral collision cross sections (i.e., apparent ion surface area or structure) from experimentally obtained IM-MS data. Special emphasis is placed on the use of imaging IM-MS for the analysis of samples in life sciences research (e.g., thin tissue sections), including selective imaging for peptide/protein and lipid distributions. Future directions for rapid and multiplexed imaging IM-MS/MS are detailed. PMID:20680602

  11. Ion microprobe mass spectrometry using sputtering atomization and resonance ionization

    SciTech Connect

    Donohue, D.L.; Christie, W.H.; Goeringer, D.E.

    1985-01-01

    Resonance ionization mass spectrometry (RIMS) has recently been developed into a useful technique for isotope ratio measurements. Studies performed in our laboratory (1-6) have been reported for a variety of elements using thermal vaporization sources to produce the atom reservoir for laser-induced resonance ionization. A commercial ion microprobe mass analyzer (IMMA) has been interfaced with a tunable pulsed dye laser for carrying out resonance ionization mass spectrometry of sputtered atoms. The IMMA instrument has many advantages for this work, including a micro-focused primary ion beam (2 ..mu..m in diameter) of selected mass, complete sample manipulation and viewing capability, and a double-focusing mass spectrometer for separation and detection of the secondary or laser-generated ions. Data were obtained demonstrating the number and type of ions formed along with optical spectral information showing the wavelengths at which resonance ionization occurs. 7 refs.

  12. Structure Determination of Natural Products by Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Biemann, Klaus

    2015-07-01

    I review laboratory research on the development of mass spectrometric methodology for the determination of the structure of natural products of biological and medical interest, which I conducted from 1958 to the end of the twentieth century. The methodology was developed by converting small peptides to their corresponding polyamino alcohols to make them amenable to mass spectrometry, thereby making it applicable to whole proteins. The structures of alkaloids were determined by analyzing the fragmentation of a known alkaloid and then using the results to deduce the structures of related compounds. Heparin-like structures were investigated by determining their molecular weights from the mass of protonated molecular ions of complexes with highly basic, synthetic peptides. Mass spectrometry was also employed in the analysis of lunar material returned by the Apollo missions. A miniaturized gas chromatograph mass spectrometer was sent to Mars on board of the two Viking 1976 spacecrafts.

  13. Structure Determination of Natural Products by Mass Spectrometry.

    PubMed

    Biemann, Klaus

    2015-01-01

    I review laboratory research on the development of mass spectrometric methodology for the determination of the structure of natural products of biological and medical interest, which I conducted from 1958 to the end of the twentieth century. The methodology was developed by converting small peptides to their corresponding polyamino alcohols to make them amenable to mass spectrometry, thereby making it applicable to whole proteins. The structures of alkaloids were determined by analyzing the fragmentation of a known alkaloid and then using the results to deduce the structures of related compounds. Heparin-like structures were investigated by determining their molecular weights from the mass of protonated molecular ions of complexes with highly basic, synthetic peptides. Mass spectrometry was also employed in the analysis of lunar material returned by the Apollo missions. A miniaturized gas chromatograph mass spectrometer was sent to Mars on board of the two Viking 1976 spacecrafts. PMID:26161970

  14. Mass Spectrometry Imaging, an Emerging Technology in Neuropsychopharmacology

    PubMed Central

    Shariatgorji, Mohammadreza; Svenningsson, Per; Andrén, Per E

    2014-01-01

    Mass spectrometry imaging is a powerful tool for directly determining the distribution of proteins, peptides, lipids, neurotransmitters, metabolites and drugs in neural tissue sections in situ. Molecule-specific imaging can be achieved using various ionization techniques that are suited to different applications but which all yield data with high mass accuracies and spatial resolutions. The ability to simultaneously obtain images showing the distributions of chemical species ranging from metal ions to macromolecules makes it possible to explore the chemical organization of a sample and to correlate the results obtained with specific anatomical features. The imaging of biomolecules has provided new insights into multiple neurological diseases, including Parkinson's and Alzheimer's disease. Mass spectrometry imaging can also be used in conjunction with other imaging techniques in order to identify correlations between changes in the distribution of important chemical species and other changes in the properties of the tissue. Here we review the applications of mass spectrometry imaging in neuroscience research and discuss its potential. The results presented demonstrate that mass spectrometry imaging is a useful experimental method with diverse applications in neuroscience. PMID:23966069

  15. Perspectives and retrospectives in mass spectrometry: one view.

    PubMed

    Cooks, R Graham; Ifa, Demian R; Sharma, Gautam; Tadjimukhamedov, Fatkhulla Kh; Ouyang, Zheng

    2010-01-01

    Mass spectrometry benefits from a flexible definition which equates it with many aspects of the science of matter in the ionized state. The field continues to expand rapidly, not only to encompass larger and more complex molecules through more powerful instruments, but simultaneously towards in-situ measurements made using smaller, more flexible and just-sufficiently-powerful instruments. The senior author has been fortunate to work in mass spectrometry from 1967 to the present and has been involved in a wide range of efforts which have covered analytical, biological, organic, instrumental and physical aspects of the subject. This effort has been made in the company of a remarkable set of colleagues. From this vantage, it is possible to look both backwards and forwards in this prospective and retrospective piece. This presentation involves a personal look at places, people, instruments, and concepts engaged in along a path through Mass Spectrometry. The journey goes from Natal, South Africa, via Cambridge, UK, through Kansas and on to Purdue University, in the great state of Indiana. It starts with natural products chemistry and moves to the physical chemistry of fragmentation and energy partitioning on to complex mixture analysis by tandem mass spectrometry and hence to the concepts of thermochemical determination by the kinetic method, preparation of materials by ion soft landing, the possible role of amino acid clusters in the origin of homochiral life, and the elaboration of a set of ambient ionization methods for chemical analysis performed using samples in their native state. Special attention is given to novel concepts and instrumentation and to the emerging areas of ambient ionization, molecular imaging and miniature mass spectrometers. Personal mass spectrometers appear to be just over the horizon as is the large-scale use of mass spectrometry in field-based analysis, including point-of-care medical diagnostics. PMID:20530836

  16. The analysis of beta-agonists by packed-column supercritical fluid chromatography with ultra-violet and atmospheric pressure chemical ionisation mass spectrometric detection.

    PubMed

    Jones, D C; Dost, K; Davidson, G; George, M W

    1999-06-01

    Packed-column supercritical fluid chromatography (pSFC) using ultra-violet (UV) and atmospheric pressure chemical ionisation (APCI) mass spectrometry (MS) provides a versatile method for the identification and quantification of beta-agonists. We have achieved good separation of clenbuterol, salbutamol, terbutaline and fenoterol with good resolution and reasonable retention times using a high concentration of methanol modifier in the supercritical CO2, together with small amounts of both acidic (trifluoroacetic acid, TFAA) and basic (triethylamine, TEA, or diethylamine, DEA) additives. APCI-MS gave unambiguous identification of the 4 analytes, and increasing cone voltage provided informative fragmentation patterns. The pSFC-MS technique was shown to be linear (R2 > or = 0.996) over the concentration range 1-50 micrograms ml-1. Single ion monitoring (SIM) gave detection limits (on-column) of 2.5 ng (clenbuterol), 0.83 ng (terbutaline), 7.6 ng (salbutamol) and 2.7 ng (fenoterol). The pSFC-MS system was shown to be reproducible within a day, between days, and between restrictors. Analysis of milk samples 'spiked' with beta-agonists showed that the matrix caused no interference, with detection limits of approximately 500 micrograms l-1 of beta-agonists. More dilute solutions could be analysed by pre-concentration before the SFC stage. PMID:10736867

  17. Electrospray and tandem mass spectrometry in biochemistry.

    PubMed Central

    Griffiths, W J; Jonsson, A P; Liu, S; Rai, D K; Wang, Y

    2001-01-01

    Over the last 20 years, biological MS has changed out of all recognition. This is primarily due to the development in the 1980s of 'soft ionization' methods that permit the ionization and vaporization of large, polar, and thermally labile biomolecules. These developments in ionization mode have driven the design and manufacture of smaller and cheaper mass analysers, making the mass spectrometer a routine instrument in the biochemistry laboratory today. In the present review the revolutionary 'soft ionization' methods will be discussed with particular reference to electrospray. The mass analysis of ions will be described, and the concept of tandem MS introduced. Where appropriate, examples of the application of MS in biochemistry will be provided. Although the present review will concentrate on the MS of peptides/proteins and lipids, all classes of biomolecules can be analysed, and much excellent work has been done in the fields of carbohydrate and nucleic acid biochemistry. PMID:11311115

  18. A New Accelerator-Based Mass Spectrometry.

    ERIC Educational Resources Information Center

    Gove, H. E.

    1983-01-01

    Tandem electrostatic accelerators produce beams of positive ions which are used to penetrate atomic nuclei in a target, inducing nuclear reactions whose study elucidates varied properties of the nucleus. Uses of the system, which acts like a mass spectrometer, are discussed. These include radiocarbon dating measurements. (JN)

  19. ALTERNATIVE IONIZATION METHODS FOR PARTICLE MASS SPECTROMETRY

    EPA Science Inventory

    The objective of this project is to enhance the capabilities of a real-time airborne particle mass spectrometer by implementing matrix-independent methods for sample ionization. The enhancements should result in improved sensitivity for trace substances and, more importantly, per...

  20. Characterization of plant materials by pyrolysis-field ionization mass spectrometry: high-resolution mass spectrometry, time-resolved high-resolution mass spectrometry, and Curie-point pyrolysis-gas chromatography/mass spectrometry of spruce needles

    SciTech Connect

    Schulten, H.F.; Simmleit, N.; Mueller, R.

    1989-02-01

    In the course of a forest damage research project spruce needles are analyzed, without pretreatment except drying and milling, by in-source pyrolysis-field ionization mass spectrometry. The mass signals are assigned by using high-resolution mass measurements and thermal degradation products identified by Curie-point pyrolysis-gas chromatography. It is demonstrated that the thermal degradation products characterize the main chemical constituents of spruce needs such as polysaccharides and lignin. Furthermore, thermostable constituents such as lipids, steroids, and flavons are detected. The thermal degradation process is studied by temperature-programmed microfurnace pyrolysis in combination with time-resolved high-resolution mass spectrometry. The integrated interpretation of results achieved by the presented methods can be applied for the universal characterization of complex and in particular nonsoluble, polydisperse biological and geochemical materials.

  1. Investigation of protein-ligand interactions by mass spectrometry.

    PubMed

    Sinz, Andrea

    2007-04-01

    The rate of drug discovery is greatly dependent on the development and improvement of rapid and reliable analytical methods that allow screening for protein-ligand interactions. The solution-based methods for investigating protein-ligand interactions by mass spectrometry (MS), which are discussed in this paper, are hydrogen/deuterium exchange of protein backbone amide hydrogens, and photoaffinity labeling. Moreover, MS analysis of intact noncovalent protein-ligand complexes is described. Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) with its ultra-high resolution and excellent mass accuracy is also considered herein as it is gaining increasing popularity for a mass spectrometric investigation of protein-ligand interactions. PMID:17299828

  2. A new derivative for oxosteroid analysis by mass spectrometry

    PubMed Central

    Rigdova, K.; Wang, Y.; Ward, M.; Griffiths, W.J.

    2014-01-01

    Here we report a new method for oxosteroid identification utilizing “tandem mass tag hydrazine” (TMTH) carbonyl-reactive derivatisation reagent. TMTH is a reagent with a chargeable tertiary amino group attached through a linker to a carbonyl-reactive hydrazine group. Thirty oxosteroids were analysed after derivatisation with TMTH by electrospray ionization mass spectrometry (ESI-MS) and were found to give high ion-currents compared to underivatised molecules. ESI-tandem mass spectrometry (MS/MS) analysis of the derivatives yielded characteristic fragmentation patterns with specific mass reporter ions derived from the TMT group. A shotgun ESI-MS method incorporating TMTH derivatisation was applied to a urine sample. PMID:24525129

  3. Absorption Mode FT-ICR Mass Spectrometry Imaging

    SciTech Connect

    Smith, Donald F.; Kilgour, David P.; Konijnenburg, Marco; O'Connor, Peter B.; Heeren, Ronald M.

    2013-12-03

    Fourier transform ion cyclotron resonance mass spectrometry offers the highest mass resolving power for molecular imaging experiments. This high mass resolving power ensures that closely spaced peaks at the same nominal mass are resolved for proper image generation. Typically higher magnetic fields are used to increase mass resolving power. However, a gain in mass resolving power can also be realized by phase correction of the data for absorption mode display. In addition to mass resolving power, absorption mode offers higher mass accuracy and signal-to-noise ratio over the conventional magnitude mode. Here we present the first use of absorption mode for Fourier transform ion cyclotron resonance mass spectrometry imaging. The Autophaser algorithm is used to phase correct each spectrum (pixel) in the image and then these parameters are used by the Chameleon work-flow based data processing software to generate absorption mode ?Datacubes? for image and spectral viewing. Absorption mode reveals new mass and spatial features that are not resolved in magnitude mode and results in improved selected ion image contrast.

  4. High-accuracy mass spectrometry for fundamental studies.

    PubMed

    Kluge, H-Jürgen

    2010-01-01

    Mass spectrometry for fundamental studies in metrology and atomic, nuclear and particle physics requires extreme sensitivity and efficiency as well as ultimate resolving power and accuracy. An overview will be given on the global status of high-accuracy mass spectrometry for fundamental physics and metrology. Three quite different examples of modern mass spectrometric experiments in physics are presented: (i) the retardation spectrometer KATRIN at the Forschungszentrum Karlsruhe, employing electrostatic filtering in combination with magnetic-adiabatic collimation-the biggest mass spectrometer for determining the smallest mass, i.e. the mass of the electron anti-neutrino, (ii) the Experimental Cooler-Storage Ring at GSI-a mass spectrometer of medium size, relative to other accelerators, for determining medium-heavy masses and (iii) the Penning trap facility, SHIPTRAP, at GSI-the smallest mass spectrometer for determining the heaviest masses, those of super-heavy elements. Finally, a short view into the future will address the GSI project HITRAP at GSI for fundamental studies with highly-charged ions. PMID:20530821

  5. May the Best Molecule Win: Competition ESI Mass Spectrometry

    PubMed Central

    Laughlin, Sarah; Wilson, W. David

    2015-01-01

    Electrospray ionization mass spectrometry has become invaluable in the characterization of macromolecular biological systems such as nucleic acids and proteins. Recent advances in the field of mass spectrometry and the soft conditions characteristic of electrospray ionization allow for the investigation of non-covalent interactions among large biomolecules and ligands. Modulation of genetic processes through the use of small molecule inhibitors with the DNA minor groove is gaining attention as a potential therapeutic approach. In this review, we discuss the development of a competition method using electrospray ionization mass spectrometry to probe the interactions of multiple DNA sequences with libraries of minor groove binding molecules. Such an approach acts as a high-throughput screening method to determine important information including the stoichiometry, binding mode, cooperativity, and relative binding affinity. In addition to small molecule-DNA complexes, we highlight other applications in which competition mass spectrometry has been used. A competitive approach to simultaneously investigate complex interactions promises to be a powerful tool in the discovery of small molecule inhibitors with high specificity and for specific, important DNA sequences. PMID:26501262

  6. Quantitative matrix-assisted laser desorption/ionization mass spectrometry

    PubMed Central

    Roder, Heinrich; Hunsucker, Stephen W.

    2008-01-01

    This review summarizes the essential characteristics of matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectrometry (TOF MS), especially as they relate to its applications in quantitative analysis. Approaches to quantification by MALDI-TOF MS are presented and published applications are critically reviewed. PMID:19106161

  7. Mass spectrometry-based detection of protein acetylation

    PubMed Central

    Li, Yu; Silva, Jeffrey C.; Skinner, Mary E.; Lombard, David B.

    2014-01-01

    Summary Improved sample preparation techniques and increasingly sensitive mass spectrometry (MS) analysis have revolutionized the study of protein post-translational modifications (PTMs). Here, we describe a general approach for immunopurification and MS-based identification of acetylated proteins in biological samples. This approach is useful characterizing changes in the acetylome in response to biological interventions (1). PMID:24014401

  8. MASS SPECTROMETRY OF INDIVIDUAL AEROSOL PARTICLES. (R823980)

    EPA Science Inventory

    Typically, in real-time aerosol mass spectrometry (RTAMS), individual airborne particles
    are ablated and ionized with a single focused laser pulse. This technique yields information that
    permits bulk characterization of the particle, but information about the particle's sur...

  9. On-Line Synthesis and Analysis by Mass Spectrometry

    ERIC Educational Resources Information Center

    Bain, Ryan M.; Pulliam, Christopher J.; Raab, Shannon A.; Cooks, R. Graham

    2015-01-01

    In this laboratory experiment, students learn how to use ESI to accelerate chemical synthesis and to couple it with on-line mass spectrometry for structural analysis. The Hantzsch synthesis of symmetric 1,4-dihydropyridines is a classic example of a one-pot reaction in which multiple intermediates can serve to indicate the progress of the reaction…

  10. MICELLAR ELECTROKINETIC CHROMATOGRAPHY-MASS SPECTROMETRY (R823292)

    EPA Science Inventory

    The combination of micellar electrokinetic chromatography (MEKC) with mass spectrometry (MS) is very attractive for the direct identification of analyte molecules, for the possibility of selectivity enhancement, and for the structure confirmation and analysis in a MS-MS mode. The...

  11. Coming to a hospital near you: mass spectrometry imaging

    ScienceCinema

    Bowen, Ben

    2014-06-24

    Berkeley Lab's Ben Bowen discusses "Coming to a hospital near you: mass spectrometry imaging" in this Oct. 28, 2013 talk, which is part of a Science at the Theater event entitled Eight Big Ideas. Go here to watch the entire event with all 8 speakers.

  12. Utility of mass spectrometry in the diagnosis of prion diseases

    Technology Transfer Automated Retrieval System (TEKTRAN)

    We developed a sensitive mass spectrometry-based method of quantitating the prions present in a variety of mammalian species. Calibration curves relating the area ratios of the selected analyte peptides and their oxidized analogs to their homologous stable isotope labeled internal standards were pre...

  13. Diagnosing Prion Diseases: Mass Spectrometry-Based Approaches

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Mass spectrometry is an established means of quantitating the prions present in infected hamsters. Calibration curves relating the area ratios of the selected analyte peptides and their oxidized analogs to stable isotope labeled internal standards were prepared. The limit of detection (LOD) and limi...

  14. Mass Spectrometry Based Identifications of LMW Glutenin Subunits

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Tandem mass spectrometry (MS/MS) is routinely used to identify wheat endosperm proteins. In this method, peptide fragmentation patterns generated by MS/MS are identified using a ‘search engine’ to compare the spectra to those generated in silico from protein sequence databases. Trypsin is a commonly...

  15. Quantification of hydroxyacetone and glycolaldehyde using chemical ionization mass spectrometry

    NASA Astrophysics Data System (ADS)

    St. Clair, J. M.; Spencer, K. M.; Beaver, M. R.; Crounse, J. D.; Paulot, F.; Wennberg, P. O.

    2014-04-01

    Chemical ionization mass spectrometry (CIMS) enables online, rapid, in situ detection and quantification of hydroxyacetone and glycolaldehyde. Two different CIMS approaches are demonstrated employing the strengths of single quadrupole mass spectrometry and triple quadrupole (tandem) mass spectrometry. Both methods are generally capable of the measurement of hydroxyacetone, an analyte with known but minimal isobaric interferences. Tandem mass spectrometry provides direct separation of the isobaric compounds glycolaldehyde and acetic acid using distinct, collision-induced dissociation daughter ions. The single quadrupole CIMS measurement of glycolaldehyde was demonstrated during the ARCTAS-CARB (Arctic Research of the Composition of the Troposphere from Aircraft and Satellites - California Air Resources Board) 2008 campaign, while triple quadrupole CIMS measurements of glycolaldehyde and hydroxyacetone were demonstrated during the BEARPEX (Biosphere Effects on Aerosols and Photochemistry Experiment) 2009 campaign. Enhancement ratios of glycolaldehyde in ambient biomass-burning plumes are reported for the ARCTAS-CARB campaign. BEARPEX observations are compared to simple photochemical box model predictions of biogenic volatile organic compound oxidation at the site.

  16. Colloquium: 100 years of mass spectrometry: Perspectives and future trends

    NASA Astrophysics Data System (ADS)

    Maher, Simon; Jjunju, Fred P. M.; Taylor, Stephen

    2015-01-01

    Mass spectrometry (MS) is widely regarded as the most sensitive and specific general purpose analytical technique. More than a century has passed for MS since the ground-breaking work of Nobel laureate Sir Joseph John Thomson in 1913. This Colloquium aims to (1) give an historical overview of the major instrumentation achievements that have driven mass spectrometry forward in the past century, including those leading up to the initial work of Thomson, (2) provide the nonspecialist with an introduction to MS, and (3) highlight some key applications of MS and explore the current and future trends. Because of the vastness of the subject area and quality of the manifold research efforts that have been undertaken over the last 100 years, which have contributed to the foundations and subsequent advances in mass spectrometry, it should be understood that not all of the key contributions may have been included in this Colloquium. Mass spectrometry has embraced a multitude of scientific disciplines and to recognize all of the achievements is an impossible task, such has been the diverse impact of this invaluable technique. Scientific progress is usually made via the cumulative effort of a large number of researchers; the achievements reported herein are only a representation of that effort.

  17. Analysis of proteins using DIGE and MALDI mass spectrometry

    EPA Science Inventory

    In this work the sensitivity of the quantitative proteomics approach 2D-DIGE/MS (twoDimensional Difference Gel Electrophoresis / Mass Spectrometry) was tested by detecting decreasing amounts of a specific protein at the low picomole and sub-picomole range. Sensitivity of the 2D-D...

  18. Multiple parallel mass spectrometry for lipid and vitamin D analysis

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Liquid chromatography (LC) coupled to mass spectrometry (MS) has become the method of choice for analysis of complex lipid samples. Two types of ionization sources have emerged as the most commonly used to couple LC to MS: atmospheric pressure chemical ionization (APCI) and electrospray ionization ...

  19. Liquid Chromatography-Mass Spectrometry-based Quantitative Proteomics

    SciTech Connect

    Xie, Fang; Liu, Tao; Qian, Weijun; Petyuk, Vladislav A.; Smith, Richard D.

    2011-07-22

    Liquid chromatography-mass spectrometry (LC-MS)-based quantitative proteomics has become increasingly applied for a broad range of biological applications due to growing capabilities for broad proteome coverage and good accuracy in quantification. Herein, we review the current LC-MS-based quantification methods with respect to their advantages and limitations, and highlight their potential applications.

  20. Probing the hydrophobic effect of noncovalent complexes by mass spectrometry.

    PubMed

    Bich, Claudia; Baer, Samuel; Jecklin, Matthias C; Zenobi, Renato

    2010-02-01

    The study of noncovalent interactions by mass spectrometry has become an active field of research in recent years. The role of the different noncovalent intermolecular forces is not yet fully understood since they tend to be modulated upon transfer into the gas phase. The hydrophobic effect, which plays a major role in protein folding, adhesion of lipid bilayers, etc., is absent in the gas phase. Here, noncovalent complexes with different types of interaction forces were investigated by mass spectrometry and compared with the complex present in solution. Creatine kinase (CK), glutathione S-transferase (GST), ribonuclease S (RNase S), and leucine zipper (LZ), which have dissociation constants in the nM range, were studied by native nanoelectrospray mass spectrometry (nanoESI-MS) and matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) combined with chemical cross-linking (XL). Complexes interacting with hydrogen bonds survived the transfer into gas phase intact and were observed by nanoESI-MS. Complexes that are bound largely by the hydrophobic effect in solution were not detected or only at very low intensity. Complexes with mixed polar and hydrophobic interactions were detected by nanoESI-MS, most likely due to the contribution from polar interactions. All noncovalent complexes could easily be studied by XL MALDI-MS, which demonstrates that the noncovalently bound complexes are conserved, and a real "snap-shot" of the situation in solution can be obtained. PMID:19931466

  1. Specialized Gas Chromatography--Mass Spectrometry Systems for Clinical Chemistry.

    ERIC Educational Resources Information Center

    Gochman, Nathan; And Others

    1979-01-01

    A discussion of the basic design and characteristics of gas chromatography-mass spectrometry systems used in clinical chemistry. A comparison of three specific systems: the Vitek Olfax IIA, Hewlett-Packard HP5992, and Du Pont DP-102 are included. (BB)

  2. DMS-prefiltered mass spectrometry for the detection of biomarkers

    NASA Astrophysics Data System (ADS)

    Coy, Stephen L.; Krylov, Evgeny V.; Nazarov, Erkinjon G.

    2008-04-01

    Technologies based on Differential Mobility Spectrometry (DMS) are ideally matched to rapid, sensitive, and selective detection of chemicals like biomarkers. Biomarkers linked to exposure to radiation, exposure to CWA's, exposure to toxic materials (TICs and TIMs) and to specific diseases are being examined in a number of laboratories. Screening for these types of exposure can be improved in accuracy and greatly speeded up by using DMS-MS instead of slower techniques like LC-MS and GC-MS. We have performed an extensive series of tests with nanospray-DMS-mass spectroscopy and standalone nanospray-DMS obtaining extensive information on chemistry and detectivity. DMS-MS systems implemented with low-resolution, low-cost, portable mass-spectrometry systems are very promising. Lowresolution mass spectrometry alone would be inadequate for the task, but with DMS pre-filtration to suppress interferences, can be quite effective, even for quantitative measurement. Bio-fluids and digests are well suited to ionization by electrospray and detection by mass-spectrometry, but signals from critical markers are overwhelmed by chemical noise from unrelated species, making essential quantitative analysis impossible. Sionex and collaborators have presented data using DMS to suppress chemical noise, allowing detection of cancer biomarkers in 10,000-fold excess of normal products 1,2. In addition, a linear dynamic range of approximately 2,000 has been demonstrated with accurate quantitation 3. We will review the range of possible applications and present new data on DMS-MS biomarker detection.

  3. Coming to a hospital near you: mass spectrometry imaging

    SciTech Connect

    Bowen, Ben

    2013-10-31

    Berkeley Lab's Ben Bowen discusses "Coming to a hospital near you: mass spectrometry imaging" in this Oct. 28, 2013 talk, which is part of a Science at the Theater event entitled Eight Big Ideas. Go here to watch the entire event with all 8 speakers.

  4. Laser Mass Spectrometry in Planetary Science

    SciTech Connect

    Wurz, P.; Whitby, J. A.; Managadze, G. G.

    2009-06-16

    Knowing the chemical, elemental, and isotopic composition of planetary objects allows the study of their origin and evolution within the context of our solar system. Exploration plans in planetary research of several space agencies consider landing spacecraft for future missions. Although there have been successful landers in the past, more landers are foreseen for Mars and its moons, Venus, the jovian moons, and asteroids. Furthermore, a mass spectrometer on a landed spacecraft can assist in the sample selection in a sample-return mission and provide mineralogical context, or identify possible toxic soils on Mars for manned Mars exploration. Given the resources available on landed spacecraft mass spectrometers, as well as any other instrument, have to be highly miniaturised.

  5. Accelerator mass spectrometry as a bioanalytical tool for nutritional research

    SciTech Connect

    Vogel, J.S.; Turteltaub, K.W.

    1997-09-01

    Accelerator Mass Spectrometry is a mass spectrometric method of detecting long-lived radioisotopes without regard to their decay products or half-life. The technique is normally applied to geochronology, but recently has been developed for bioanalytical tracing. AMS detects isotope concentrations to parts per quadrillion, quantifying labeled biochemicals to attomole levels in milligram- sized samples. Its advantages over non-isotopeic and stable isotope labeling methods are reviewed and examples of analytical integrity, sensitivity, specificity, and applicability are provided.

  6. Statistical design of mass spectrometry calibration procedures

    SciTech Connect

    Bayne, C.K.

    1996-11-01

    The main objective of this task was to agree on calibration procedures to estimate the system parameters (i.e., dead-time correction, ion-counting conversion efficiency, and detector efficiency factors) for SAL`s new Finnigan MAT-262 mass spectrometer. SAL will use this mass spectrometer in a clean-laboratory which was opened in December 1995 to measure uranium and plutonium isotopes on environmental samples. The Finnigan MAT-262 mass spectrometer has a multi-detector system with seven Faraday cup detectors and one ion- counter for the measurement of very small signals (e.g. 10{sup -17} Ampere range). ORNL has made preliminary estimates of the system parameters based on SAL`s experimental data measured in late 1994 when the Finnigan instrument was relatively new. SAL generated additional data in 1995 to verify the calibration procedures for estimating the dead-time correction factor, the ion-counting conversion factor and the Faraday cup detector efficiency factors. The system parameters estimated on the present data will have to be reestablished when the Finnigan MAT-262 is moved-to the new clean- laboratory. Different methods will be used to analyzed environmental samples than the current measurement methods being used. For example, the environmental samples will be electroplated on a single filament rather than using the current two filament system. An outline of the calibration standard operating procedure (SOP) is included.

  7. Application of Laser Mass Spectrometry to Art and Archaeology

    NASA Technical Reports Server (NTRS)

    Gulian, Lase Lisa E.; Callahan, Michael P.; Muliadi, Sarah; Owens, Shawn; McGovern, Patrick E.; Schmidt, Catherine M.; Trentelman, Karen A.; deVries, Mattanjah S.

    2011-01-01

    REMPI laser mass spectrometry is a combination of resonance enhanced multiphoton ionization spectroscopy and time of flight mass spectrometry, This technique enables the collection of mass specific optical spectra as well as of optically selected mass spectra. Analytes are jet-cooled by entrainment in a molecular beam, and this low temperature gas phase analysis has the benefit of excellent vibronic resolution. Utilizing this method, mass spectrometric analysis of historically relevant samples can be simplified and improved; Optical selection of targets eliminates the need for chromatography while knowledge of a target's gas phase spectroscopy allows for facile differentiation of molecules that are in the aqueous phase considered spectroscopically indistinguishable. These two factors allow smaller sample sizes than commercial MS instruments, which in turn will require less damage to objects of antiquity. We have explored methods to optimize REMPI laser mass spectrometry as an analytical tool to archaeology using theobromine and caffeine as molecular markers in Mesoamerican pottery, and are expanding this approach to the field of art to examine laccaic acid in shellacs.

  8. On the structural denaturation of biological analytes in trapped ion mobility spectrometry - mass spectrometry.

    PubMed

    Liu, Fanny C; Kirk, Samuel R; Bleiholder, Christian

    2016-06-01

    Key to native ion mobility/mass spectrometry is to prevent the structural denaturation of biological molecules in the gas phase. Here, we systematically assess structural changes induced in the protein ubiquitin during a trapped ion mobility spectrometry (TIMS) experiment. Our analysis shows that the extent of structural denaturation induced in ubiquitin ions is largely proportional to the amount of translational kinetic energy an ion gains from the applied electric field between two collisions with buffer gas particles. We then minimize the efficiency of the structural denaturation of ubiquitin ions in the gas phase during a TIMS experiment. The resulting "soft" TIMS spectra of ubiquitin are found largely identical to those observed on "soft" elevated-pressure ion mobility drift tubes and the corresponding calibrated cross sections are consistent with structures reported from NMR experiments for the native and A-state of ubiquitin. Thus, our analysis reveals that TIMS is useful for native ion mobility/mass spectrometry analysis. PMID:26998732

  9. MASS SPECTROMETRY IMAGING FOR DRUGS AND METABOLITES

    PubMed Central

    Greer, Tyler; Sturm, Robert; Li, Lingjun

    2011-01-01

    Mass spectrometric imaging (MSI) is a powerful analytical technique that provides two- and three-dimensional spatial maps of multiple compounds in a single experiment. This technique has been routinely applied to protein, peptide, and lipid molecules with much less research reporting small molecule distributions, especially pharmaceutical drugs. This review’s main focus is to provide readers with an up-to-date description of the substrates and compounds that have been analyzed for drug and metabolite composition using MSI technology. Additionally, ionization techniques, sample preparation, and instrumentation developments are discussed. PMID:21515430

  10. Hands-on Electrospray Ionization-Mass Spectrometry for Upper-Level Undergraduate and Graduate Students

    ERIC Educational Resources Information Center

    Stock, Naomi L.; March, Raymond E.

    2014-01-01

    Electrospray ionization-mass spectrometry (ESI-MS) is a powerful technique for the detection, identification, and quantification of organic compounds. As mass spectrometers have become more user-friendly and affordable, many students--often with little experience in mass spectrometry--find themselves needing to incorporate mass spectrometry into…

  11. Tandem mass spectrometry for sequencing proanthocyanidins.

    PubMed

    Li, Hui-Jing; Deinzer, Max L

    2007-02-15

    Proanthocyanidins (PAs) are a group of bioflavonoids consisting of oligomers based on catechin monomeric units. These polyphenolic compounds are widely distributed in higher plants and are an integral part of the human diet. A sensitive LC-tandem mass spectrometric (LC/ESI-MS(n)) method in the positive ion mode for sequencing these ubiquitous and highly beneficial antioxidants is described. The hydroxylation patterns and interflavanoid linkage for A- and B-type PAs were determined by fragment ions derived from a retro-Diels-Alder (RDA) fission, heterocyclic ring fission (HRF), a novel benzofuran-forming (BFF) fission described here for the first time, and a quinone methide (QM) fission. The subunit sequence of the PAs was determined by diagnostic ions derived from HRF/RDA fission, HRF/BFF fission, and RDA/HRF fission together with QM fission. A total of 26 PAs were reliably sequenced by the newly established tandem mass spectrometric protocol. It is shown that the protocol based on a combination of these different fragmentation patterns allows for uniquely identifying PA oligomers. PMID:17297981

  12. Environmental applications for the analysis of chlorinated dibenzo-p-dioxins and dibenzofurans using mass spectrometry/mass spectrometry

    SciTech Connect

    Reiner, E.J.; Schellenberg, D.H.; Taguchi, V.Y. )

    1991-01-01

    A mass spectrometry/mass spectrometry-multiple reaction monitoring (MS/MS-MRM) technique for the analysis of all tetra- through octachlorinated dibenzo-p-dioxins (Cl{sub x}DD, x = 4-8) and dibenzofurans (Cl{sub x}DF, x = 4-8) has been developed at the Ministry of the Environment (MOE) utilizing a triple quadrupole mass spectrometer. Optimization of instrumental parameters using the analyte of interest in a direct insertion probe (DIP) resulted in sensitivities approaching those obtainable by high-resolution mass spectrometric (HRMS) methods. All congeners of dioxins and furans were detected in the femtogram range. Results on selected samples indicated that for some matrices, fewer chemical interferences were observed by MS/MS than by HRMS. The technique used to optimize the instrument for chlorinated dibenzo-p-dioxins (CDDs) and chlorinated dibenzofurans (CDFs) analysis is adaptable to other analytes.

  13. Direct coupling of packed column supercritical fluid chromatography to continuous corona discharge ion mobility spectrometry.

    PubMed

    Rahmanian, A; Ghaziaskar, H S; Khayamian, T

    2013-01-11

    In this study, packed column supercritical fluid chromatography (SFC) was directly coupled to a continuous corona discharge (CD) ion mobility spectrometer (IMS) with several modifications. The main advantage of the developed detector is its capability to introduce full column effluent up to 2000 mL min(-1) CO(2) gas directly into the IMS cell relative to 40 mL min(-1) CO(2) gas as a maximum tolerance, reported for the previous IMS detectors. This achievement was made possible because of using corona discharge instead of (63)Ni as an ionization source and locating the inlet and outlet of the CO(2) gas in the counter electrode of the CD in opposite direction. In addition, a heated interface was placed between back pressure regulator (BPR) and the IMS cell to heat the output of the BPR for introducing sample as the gas phase into the IMS cell. Furthermore, a make-up methanol flow was introduced between the column outlet and BPR to provide a more uniform flow through the BPR and also to prevent freezing and deposition of the analytes in the BPR. The performance of the SFC-CD-IMS was evaluated by analysis of testosterone, medroxyprogesterone, caffeine, and theophylline as test compounds and figures of merit for these compounds have been calculated. PMID:23261285

  14. Complete Hexose Isomer Identification with Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Nagy, Gabe; Pohl, Nicola L. B.

    2015-04-01

    The first analytical method is presented for the identification and absolute configuration determination of all 24 aldohexose and 2-ketohexose isomers, including the D and L enantiomers for allose, altrose, galactose, glucose, gulose, idose, mannose, talose, fructose, psicose, sorbose, and tagatose. Two unique fixed ligand kinetic method combinations were discovered to create significant enough energetic differences to achieve chiral discrimination among all 24 hexoses. Each of these 24 hexoses yields unique ratios of a specific pair of fragment ions that allows for simultaneous determination of identification and absolute configuration. This mass spectrometric-based methodology can be readily employed for accurate identification of any isolated monosaccharide from an unknown biological source. This work provides a key step towards the goal of complete de novo carbohydrate analysis.

  15. Developments in Noble Gas mass spectrometry

    NASA Astrophysics Data System (ADS)

    Hamilton, D.; Schwieters, J. B.; Lloyd, N. S.

    2010-12-01

    D. HAMILTON*, J.B. SCHWIETERS, D. TUTTAS, M. KRUMMEN, M. DEERBERG, N.S. LLOYD1 1Thermo Fisher Scientific, Hanna-Kunath-Str. 11, 28199 Bremen, Germany (*correspondence: Doug.Hamilton@ThermoFisher.com) Recent advances in ion optics and electronic design have added features to the new range of Noble Gas mass spectrometers from Thermo Fisher Scientific that will enable the scientific community to resolve a number of existing analytical limitations. The first development relates to detector technology. Because instrument transmission and ion source efficiency can be very high, detector noise can be the limiting factor for ultra-small sample analysis. Faraday cup detectors are the detectors of choice for high accuracy and high precision isotope ratio measurements because of their unmatched stability and linearity and because of the electronic cross calibration network available to precisely and accurately cross calibrate the multiple Faraday detector channels against each other. Today, most IOMS systems are equipped with current amplifiers using a 1011 Ohm resistor coupled to the feedback loop of a high stability and temperature-stabilized operational amplifier. In this paper we will describe our latest investigations in Faraday cup measurements utilising 1012 & 1013 resistors for signal intensities in the range of 1 pA to 1 fA. The second development relates to a new beam deflection technology added to the ARGUS VI mass spectrometer that enables a fixed collector array to be given some of the properties of a mechanically adjustable array. This enables multidynamic multicollector measurements to be taken utilising a fixed array thus enabling the end user to perform vital detector crosscalibrations “in run”. Lastly we will describe early results on a new high resolution platform and the capabilities of this platform to finally deal with certain isotopic interferences in both the Argon and Neon spectra.

  16. Resonant Laser Ionization Mass Spectrometry: An Alternative to AMS?

    SciTech Connect

    Wendt, Klaus; Trautmann, N.; Bushaw, Bruce A.

    2001-02-15

    Resonant laser ionization mass spectrometry (RIMS) has developed into a versatile experimental method particularly concerning applications for highly selective ultratrace analaysis. Apart from providing nearly complete isobaric suspression and high overall efficiency, the possibolility for combining optical isotpic selectivity with that of hte mass spectrometer leads to remarkable specifications. The widespread analytical potential and applicability of different techniques based on resonant laser ionization is demonstrated in investigations on stable and radioactive ultratrace isotopes with the focus on applications which require high selectivity, concerning, e.g., the noble gas isotopes, 81,85KR, PU isotopes, 89,90SR, 99Tc and 41Ca. Selective ultratrace determination of these radioisotopes proved access to a variety of fundamental research problems in environmental sciences, geo- and cosmochemistry, archaeology, and biomedicine, which previously were often an exclusive domain for accelerator mass spectrometry (AMS).

  17. Recent developments in Penning-trap mass spectrometry

    NASA Astrophysics Data System (ADS)

    Block, M.

    2016-06-01

    Penning-trap mass spectrometry provides atomic masses with the highest precision. At accelerator-based on-line facilities it is applied to investigate exotic radionuclides in the context of tests of fundamental symmetries, nuclear structure studies, and nuclear astrophysics research. Recent progress in slowing down radioactive ion-beams in buffer-gas cells in combination with advanced ion-manipulation techniques has paved the way to reach nuclides ever-more far from stability. In this endeavor many efforts are underway to increase the sensitivity, the efficiency, and the precision of Penning-trap mass spectrometry. In this article some recent experimental developments are addressed with the focus on the phase-imaging ion-cyclotron-resonance technique and the Fourier transform ion-cyclotron-resonance technique.

  18. Determination of 135Cs by accelerator mass spectrometry

    NASA Astrophysics Data System (ADS)

    MacDonald, C. M.; Charles, C. R. J.; Zhao, X.-L.; Kieser, W. E.; Cornett, R. J.; Litherland, A. E.

    2015-10-01

    The ratio of anthropogenic 135Cs and 137Cs isotopes is characteristic of a uranium fission source. This research evaluates the technique of isotope dilution (yield tracing) for the purpose of quantifying 135Cs by accelerator mass spectrometry with on-line isobar separation. Interferences from Ba, Zn2, and isotopes of equal mass to charge ratios were successfully suppressed. However, some sample crosstalk from source contamination remains. The transmission and di-fluoride ionization efficiencies of Cs isotopes were found to be 8 × 10-3 and 1.7 × 10-7 respectively. This quantification of 135Cs using yield tracing by accelerator mass spectrometry shows promise for future environmental sample analysis once the issues of sample crosstalk and low efficiency can be resolved.

  19. Identification of metabolites of hexazinone by mass spectrometry.

    PubMed

    Reiser, R W; Belasco, I J; Rhodes, R C

    1983-11-01

    The metabolites of hexazinone [3-cyclohexyl-6-(dimethylamino)-1-methyl-1,3,5-triazine-2,4(1H,3H)-dione ] obtained in the rat and in plants were identified by mass spectrometry. Rat urine metabolites were identified from direct probe spectra obtained on metabolites separated by thin-layer chromatography. Sugarcane metabolites were identified by gas chromatography mass spectrometry of the trimethylsilyl derivatives. The major metabolic routes were found to be hydroxylation of the cyclohexyl group and demethylation. All identifications were confirmed by synthesis and direct comparison of chromatographic data and mass spectra. Hexazinone is metabolized quickly and extensively in the biological systems studied, and is relatively nonpersistent in the environment. PMID:6661503

  20. LILBID-mass spectrometry of the mitochondrial preprotein translocase TOM

    NASA Astrophysics Data System (ADS)

    Mager, Frauke; Sokolova, Lucie; Lintzel, Julia; Brutschy, Bernhard; Nussberger, Stephan

    2010-11-01

    In the present work we applied a novel mass spectrometry method termed laser-induced liquid bead ion desorption mass spectrometry (LILBID-MS) to the outer mitochondrial membrane protein translocon TOM to analyze its subunit composition and stoichiometry. With TOM core complex, purified at high pH, we demonstrate that a TOM core complex of Neurospora crassa is composed of at least two Tom40 and Tom22 molecules, respectively, and more than five small Tom subunits between 5.5 and 6.4 kDa. We show that the multiprotein complex has a total molecular mass higher than 170 depending on the number of Tom5, Tom6 and Tom7 molecules bound.

  1. Advances in structure elucidation of small molecules using mass spectrometry

    PubMed Central

    Fiehn, Oliver

    2010-01-01

    The structural elucidation of small molecules using mass spectrometry plays an important role in modern life sciences and bioanalytical approaches. This review covers different soft and hard ionization techniques and figures of merit for modern mass spectrometers, such as mass resolving power, mass accuracy, isotopic abundance accuracy, accurate mass multiple-stage MS(n) capability, as well as hybrid mass spectrometric and orthogonal chromatographic approaches. The latter part discusses mass spectral data handling strategies, which includes background and noise subtraction, adduct formation and detection, charge state determination, accurate mass measurements, elemental composition determinations, and complex data-dependent setups with ion maps and ion trees. The importance of mass spectral library search algorithms for tandem mass spectra and multiple-stage MS(n) mass spectra as well as mass spectral tree libraries that combine multiple-stage mass spectra are outlined. The successive chapter discusses mass spectral fragmentation pathways, biotransformation reactions and drug metabolism studies, the mass spectral simulation and generation of in silico mass spectra, expert systems for mass spectral interpretation, and the use of computational chemistry to explain gas-phase phenomena. A single chapter discusses data handling for hyphenated approaches including mass spectral deconvolution for clean mass spectra, cheminformatics approaches and structure retention relationships, and retention index predictions for gas and liquid chromatography. The last section reviews the current state of electronic data sharing of mass spectra and discusses the importance of software development for the advancement of structure elucidation of small molecules. Electronic supplementary material The online version of this article (doi:10.1007/s12566-010-0015-9) contains supplementary material, which is available to authorized users. PMID:21289855

  2. Precise atomic mass measurements by deflection mass spectrometry

    NASA Astrophysics Data System (ADS)

    Barber, R. C.; Sharma, K. S.

    2003-05-01

    Since its inception nearly 90 years ago by J.J. Thomson, the precise determination of atomic masses by the classical technique of deflecting charged particles in electric and magnetic fields has provided a large body of data on naturally occurring nuclides. Currently, such measurements on stable nuclides have frequently achieved a precision of better than two parts in 10 9 of the mass. A review of the technique, together with a brief summary of the important historical developments in the field of precise atomic mass measurements, will be given. The more recent contributions to this field by the deflection mass spectrometer at the University of Manitoba will be provided as illustrations of the culmination of the techniques used and the applications that have been studied. A brief comparison between this and newer techniques using Penning traps will be presented.

  3. POTAMOS mass spectrometry calculator: computer aided mass spectrometry to the post-translational modifications of proteins. A focus on histones.

    PubMed

    Vlachopanos, A; Soupsana, E; Politou, A S; Papamokos, G V

    2014-12-01

    Mass spectrometry is a widely used technique for protein identification and it has also become the method of choice in order to detect and characterize the post-translational modifications (PTMs) of proteins. Many software tools have been developed to deal with this complication. In this paper we introduce a new, free and user friendly online software tool, named POTAMOS Mass Spectrometry Calculator, which was developed in the open source application framework Ruby on Rails. It can provide calculated mass spectrometry data in a time saving manner, independently of instrumentation. In this web application we have focused on a well known protein family of histones whose PTMs are believed to play a crucial role in gene regulation, as suggested by the so called "histone code" hypothesis. The PTMs implemented in this software are: methylations of arginines and lysines, acetylations of lysines and phosphorylations of serines and threonines. The application is able to calculate the kind, the number and the combinations of the possible PTMs corresponding to a given peptide sequence and a given mass along with the full set of the unique primary structures produced by the possible distributions along the amino acid sequence. It can also calculate the masses and charges of a fragmented histone variant, which carries predefined modifications already implemented. Additional functionality is provided by the calculation of the masses of fragments produced upon protein cleavage by the proteolytic enzymes that are most widely used in proteomics studies. PMID:25450216

  4. Trends in biochemical and biomedical applications of mass spectrometry

    NASA Astrophysics Data System (ADS)

    Gelpi, Emilio

    1992-09-01

    This review attempts an in-depth evaluation of progress and achievements made since the last 11th International Mass Spectrometry Conference in the application of mass spectrometric techniques to biochemistry and biomedicine. For this purpose, scientific contributions in this field at major international meetings have been monitored, together with an extensive appraisal of literature data covering the period from 1988 to 1991. A bibliometric evaluation of the MEDLINE database for this period provides a total of almost 4000 entries for mass spectrometry. This allows a detailed study of literature and geographical sources of the most frequent applications, of disciplines where mass spectrometry is most active and of types of sample and instrumentation most commonly used. In this regard major efforts according to number of publications (over 100 literature reports) are concentrated in countries like Canada, France, Germany, Italy, Japan, Sweden, UK and the USA. Also, most of the work using mass spectrometry in biochemistry and biomedicine is centred on studies on biotransformation, metabolism, pharmacology, pharmacokinetics and toxicology, which have been carried out on samples of blood, urine, plasma and tissue, by order of frequency of use. Human and animal studies appear to be evenly distributed in terms of the number of reports published in the literature in which the authors make use of experimental animals or describe work on human samples. Along these lines, special attention is given to the real usefulness of mass spectrometry (MS) technology in routine medical practice. Thus the review concentrates on evaluating the progress made in disease diagnosis and overall patient care. As regards prevailing techniques, GCMS continues to be the mainstay of the state of the art methods for multicomponent analysis, stable isotope tracer studies and metabolic profiling, while HPLC--MS and tandem MS are becoming increasingly important in biomedical research. However

  5. Microscale mass spectrometry systems, devices and related methods

    DOEpatents

    Ramsey, John Michael

    2016-06-21

    Mass spectrometry systems or assemblies therefore include an ionizer that includes at least one planar conductor, a mass analyzer with a planar electrode assembly, and a detector comprising at least one planar conductor. The ionizer, the mass analyzer and the detector are attached together in a compact stack assembly. The stack assembly has a perimeter that bounds an area that is between about 0.01 mm.sup.2 to about 25 cm.sup.2 and the stack assembly has a thickness that is between about 0.1 mm to about 25 mm.

  6. Small system for tritium accelerator mass spectrometry

    DOEpatents

    Roberts, M.L.; Davis, J.C.

    1993-02-23

    Apparatus for ionizing and accelerating a sample containing isotopes of hydrogen and detecting the ratios of hydrogen isotopes contained in the sample is disclosed. An ion source generates a substantially linear ion beam including ions of tritium from the sample. A radio-frequency quadrupole accelerator is directly coupled to and axially aligned with the source at an angle of substantially zero degrees. The accelerator accelerates species of the sample having different mass to different energy levels along the same axis as the ion beam. A spectrometer is used to detect the concentration of tritium ions in the sample. In one form of the invention, an energy loss spectrometer is used which includes a foil to block the passage of hydrogen, deuterium and [sup 3]He ions, and a surface barrier or scintillation detector to detect the concentration of tritium ions. In another form of the invention, a combined momentum/energy loss spectrometer is used which includes a magnet to separate the ion beams, with Faraday cups to measure the hydrogen and deuterium and a surface barrier or scintillation detector for the tritium ions.

  7. Small system for tritium accelerator mass spectrometry

    DOEpatents

    Roberts, Mark L.; Davis, Jay C.

    1993-01-01

    Apparatus for ionizing and accelerating a sample containing isotopes of hydrogen and detecting the ratios of hydrogen isotopes contained in the sample is disclosed. An ion source generates a substantially linear ion beam including ions of tritium from the sample. A radio-frequency quadrupole accelerator is directly coupled to and axially aligned with the source at an angle of substantially zero degrees. The accelerator accelerates species of the sample having different mass to different energy levels along the same axis as the ion beam. A spectrometer is used to detect the concentration of tritium ions in the sample. In one form of the invention, an energy loss spectrometer is used which includes a foil to block the passage of hydrogen, deuterium and .sup.3 He ions, and a surface barrier or scintillation detector to detect the concentration of tritium ions. In another form of the invention, a combined momentum/energy loss spectrometer is used which includes a magnet to separate the ion beams, with Faraday cups to measure the hydrogen and deuterium and a surface barrier or scintillation detector for the tritium ions.

  8. Data Analysis Methods for Synthetic Polymer Mass Spectrometry: Autocorrelation

    PubMed Central

    Wallace, William E.; Guttman, Charles M.

    2002-01-01

    Autocorrelation is shown to be useful in describing the periodic patterns found in high- resolution mass spectra of synthetic polymers. Examples of this usefulness are described for a simple linear homopolymer to demonstrate the method fundamentals, a condensation polymer to demonstrate its utility in understanding complex spectra with multiple repeating patterns on different mass scales, and a condensation copolymer to demonstrate how it can elegantly and efficiently reveal unexpected phenomena. It is shown that using autocorrelation to determine where the signal devolves into noise can be useful in determining molecular mass distributions of synthetic polymers, a primary focus of the NIST synthetic polymer mass spectrometry effort. The appendices describe some of the effects of transformation from time to mass space when time-of-flight mass separation is used, as well as the effects of non-trivial baselines on the autocorrelation function.

  9. Chemically assisted laser ablation ICP mass spectrometry.

    PubMed

    Hirata, Takafumi

    2003-01-15

    A new laser ablation technique combined with a chemical evaporation reaction has been developed for elemental ratio analysis of solid samples using an inductively coupled plasma mass spectrometer (ICPMS). Using a chemically assisted laser ablation (CIA) technique developed in this study, analytical repeatability of the elemental ratio measurement was successively improved. To evaluate the reliability of the CLA-ICPMS technique, Pb/U isotopic ratios were determined for zircon samples that have previously been analyzed by other techniques. Conventional laser ablation for Pb/U shows a serious elemental fractionation during ablation mainly due to the large difference in elemental volatility between Pb and U. In the case of Pb/U ratio measurement, a Freon R-134a gas (1,1,1,2-tetrafluoroethane) was introduced into the laser cell as a fluorination reactant. The Freon gas introduced into the laser cell reacts with the ablated sample U, and refractory U compounds are converted to a volatile U fluoride compound (UF6) under the high-temperature condition at the ablation site. This avoids the redeposition of U around the ablation pits. Although not all the U is reacted with Freon, formation of volatile UF compounds improves the transmission efficiency of U. Typical precision of the 206Pb/238U ratio measurement is 3-5% (2sigma) for NIST SRM 610 and Nancy 91500 zircon standard, and the U-Pb age data obtained here show good agreement within analytical uncertainties with the previously reported values. Since the observed Pb/U ratio for solid samples is relatively insensitive to laser power and ablation time, optimization of ablation conditions or acquisition parameters no longer needs to be performed on a sample-to-sample basis. PMID:12553756

  10. Electrospray Ionization Mass Spectrometry of hexanitrohexaazaisowurtzitane (CL-20)

    SciTech Connect

    Campbell, James A.; Szecsody, Jim E.; Devary, Brooks J.; Valenzuela, Blandina R.

    2007-09-03

    Hexanitrohexaazaisowurtzitane, (C6H6N12O12, MW 438) {CL-20}, is a high-energy propellent that has been recently developed and successfully tested (Nielsen et al. 1998). CL-20 releases more energy on ignition and is more stable to accidental detonation than currently used energetic materials. It is expected to replace many of the energetic materials currently being used by the Department of Defense (DoD). The EPA method 8330 (EPA 1997) for the analysis of explosives and metabolites in soils calls for the use of UV/Vis detection. High performance liquid chromatography has been used to quantify CL-20 and precursor concentration (Bazaki et al. 1998`) at relatively high concentrations. Fourier transform infrared (FTIR) spectroscopy has been used to identify different crystal forms of CL-20 (4 isomers; Kim et al. 1998). Campbell et al. (1997) utilized particle beam mass spectrometry for the analysis of enzymatic degradation of explosives. Introduction and recent improvements of ionization techniques such as electrospray (ES) have allowed the mass spectrometer to become more widely used in liquid chromatography. Schilling(1996) also examined explosive components and metabolites using electrospray (ES) and atmospheric pressure chemical ionization (APCI) liquid chromatography/mass spectrometry (LC/MS). Schilling’s results showed that compared to thermospray LC/MS, APCI and ES were more sensitive than thermospray by at least an order of magnitude. 1,3,5-trinitro-1,3,5-triazacyclohexane (RDX), 10 nitroso-RDX metabolites, and other munitions in ground water have been analyzed using solid phase extraction and isotope dilution liquid chromatography-APCI mass spectrometry (Cassada et al. 1999). The method detection limits indicate that nitramine and nitroaromatic compounds can be routinely determined in ground water samples using electrospray LC/MS with concentration techniques utilizing solid-phase extraction. Miller et al. (1996) studied nitrated explosives with mobile phase

  11. Optimization of Whole-Body Zebrafish Sectioning Methods for Mass Spectrometry Imaging

    EPA Science Inventory

    Mass spectrometry imaging methods and protocols have become widely adapted to a variety of tissues and species. However, the mass spectrometry imaging literature contains minimal information on whole-body cryosection preparation for the zebrafish (Danio rerio), a model organism ...

  12. "EMERGING" POLLUTANTS, MASS SPECTROMETRY, AND COMMUNICATING SCIENCE: PHARMACEUTICALS IN THE ENVIRONMENT

    EPA Science Inventory

    A foundation for Environmental Science - Mass Spectrometry: Historically fundamental to amassing our understanding of environmental processes and chemical pollution is the realm of mass spectrometry - the mainstay of analytical chemistry - the workhorse that supplies much of the...

  13. Advances in 193 nm excimer lasers for mass spectrometry applications

    NASA Astrophysics Data System (ADS)

    Delmdahl, Ralph; Esser, Hans-Gerd; Bonati, Guido

    2016-03-01

    Ongoing progress in mass analysis applications such as laser ablation inductively coupled mass spectrometry of solid samples and ultraviolet photoionization mediated sequencing of peptides and proteins is to a large extent driven by ultrashort wavelength excimer lasers at 193 nm. This paper will introduce the latest improvements achieved in the development of compact high repetition rate excimer lasers and elaborate on the impact on mass spectrometry instrumentation. Various performance and lifetime measurements obtained in a long-term endurance test over the course of 18 months will be shown and discussed in view of the laser source requirements of different mass spectrometry tasks. These sampling type applications are served by excimer lasers delivering pulsed 193 nm output of several mJ as well as fast repetition rates which are already approaching one Kilohertz. In order to open up the pathway from the laboratory to broader market industrial use, sufficient component lifetimes and long-term stable performance behavior have to be ensured. The obtained long-term results which will be presented are based on diverse 193 nm excimer laser tube improvements aiming at e.g. optimizing the gas flow dynamics and have extended the operational life the laser tube for the first time over several billion pulses even under high duty-cycle conditions.

  14. Identification of carbohydrate anomers using ion mobility-mass spectrometry

    NASA Astrophysics Data System (ADS)

    Hofmann, J.; Hahm, H. S.; Seeberger, P. H.; Pagel, K.

    2015-10-01

    Carbohydrates are ubiquitous biological polymers that are important in a broad range of biological processes. However, owing to their branched structures and the presence of stereogenic centres at each glycosidic linkage between monomers, carbohydrates are harder to characterize than are peptides and oligonucleotides. Methods such as nuclear magnetic resonance spectroscopy can be used to characterize glycosidic linkages, but this technique requires milligram amounts of material and cannot detect small amounts of coexisting isomers. Mass spectrometry, on the other hand, can provide information on carbohydrate composition and connectivity for even small amounts of sample, but it cannot be used to distinguish between stereoisomers. Here, we demonstrate that ion mobility-mass spectrometry--a method that separates molecules according to their mass, charge, size, and shape--can unambiguously identify carbohydrate linkage-isomers and stereoisomers. We analysed six synthetic carbohydrate isomers that differ in composition, connectivity, or configuration. Our data show that coexisting carbohydrate isomers can be identified, and relative concentrations of the minor isomer as low as 0.1 per cent can be detected. In addition, the analysis is rapid, and requires no derivatization and only small amounts of sample. These results indicate that ion mobility-mass spectrometry is an effective tool for the analysis of complex carbohydrates. This method could have an impact on the field of carbohydrate synthesis similar to that of the advent of high-performance liquid chromatography on the field of peptide assembly in the late 1970s.

  15. New Types of Ionization Sources for Mass Spectrometry

    SciTech Connect

    2008-12-01

    The purpose of this Cooperative Research and Development Agreement (CRADA) between UT-Battelle (Contractor) and MDS Sciex (Participant) and ESA, Inc. (Participant) is to research, develop and apply new types of ionization sources and sampling/inlet systems for analytical mass spectrometry making use of the Participants state-of-the-art atmospheric sampling mass spectrometry electrochemical cell technology instrumentation and ancillary equipment. The two overriding goals of this research project are: to understand the relationship among the various instrumental components and operational parameters of the various ion sources and inlet systems under study, the chemical nature of the gases, solvents, and analytes in use, and the nature and abundances of the ions ultimately observed in the mass spectrometer; and to develop new and better analytical and fundamental applications of these ion sources and inlet systems or alternative sources and inlets coupled with mass spectrometry on the basis of the fundamental understanding obtained in Goal 1. The end results of this work are expected to be: (1) an expanded utility for the ion sources and inlet systems under study (such as the analysis of new types of analytes) and the control or alteration of the ionic species observed in the gas-phase; (2) enhanced instrument performance as judged by operational figures-of-merit such as dynamic range, detection limits, susceptibility to matrix signal suppression and sensitivity; and (3) novel applications (such as surface sampling with electrospray) in both applied and fundamental studies. The research projects outlined herein build upon work initiated under the previous CRADA between the Contractor and MDS Sciex on ion sources and inlet systems for mass spectrometry. Specific ion source and inlet systems for exploration of the fundamental properties and practical implementation of these principles are given.

  16. Characterization of a novel diclofenac metabolite in human urine by capillary gas chromatography-negative chemical ionization mass spectrometry.

    PubMed

    Blum, W; Faigle, J W; Pfaar, U; Sallmann, A

    1996-10-25

    A sensitive analytical method was developed to characterize diclofenac metabolites in small amounts of body fluids. Desalted and lyophilized urine samples were extracted with supercritical carbon dioxide directly or after acidic hydrolysis. The extracts were derivatized with N-tert.-butyldimethylsilyl-N-methyltrifluoroacetamide. The derivatives were separated by capillary gas chromatography and identified by negative chemical ionization mass spectrometry. Full mass spectra were obtained at a level of 1.10(-9) g/ml. With direct extraction, the metabolites could be analysed in one step as open-chained acids and as (cyclic) oxindoles. By acidic hydrolysis the conjugates were transformed to the oxindoles. With both methods, a new main metabolite, [2-[2,6-dichloro-4-hydroxy-3-methoxyphenyl)amino]phenyl]acetic acid, was identified The mechanism of its formation is discussed. PMID:8953166

  17. Application of Mass Spectrometry in the Synthesis and Characterization of Metal Nanoclusters.

    PubMed

    Lu, Yizhong; Chen, Wei

    2015-11-01

    In recent years, mass spectrometry has been widely used in the characterization of metal nanoclusters. In this Feature, we first give an introductory tutorial on mass spectrometry and then highlight the versatile applications of mass spectrometry in accurately analyzing core size, atom-level composition, charge states, etc. of metal nanoclusters and size evolution during synthesis. Finally, some perspectives on the future applications of mass spectrometry in nanocluster research are given. PMID:26086315

  18. Negative thermal ion mass spectrometry of oxygen in phosphates

    NASA Astrophysics Data System (ADS)

    Holmden, C.; Papanastassiou, D. A.; Wasserburg, G. J.

    1997-06-01

    A novel technique for the precise measurement of oxygen isotopes by negative thermal ion mass spectrometry (NTIMS) is presented. The technique is ideally suited to the analysis of oxygen isotopes in phosphates which form intense P03 ion beams. Since P is monoisotopic, the mass spectrum for P0 3- at 79, 80, and 81 corresponds to 1660, 170, and 180. Natural and synthetic phosphates are converted and loaded on the mass spectrometer filament as Ag 3PO 4 precipitated directly from ammoniacal solution. To lower the work function of the filament, BaCl, is added in a 1:1 molar ratio of PO 4:Ba. Using these procedures, Br - mass interference (at 79 and 81 amu) is eliminated for typical analyses. Experiments with 180-enriched water show less than 1 % O-exchange between sample PO 4 and adsorbed water, and there is no O-exchange with trace OZ present in the mass spectrometer source chamber. The ionization efficiency of PO 4, as P0 3- is >10% compared to 0.01% for both conventional dual inlet Gas Isotope Ratio Mass Spectrometry (GIRMS) and secondary ion mass spectrometry (SIMS). Therefore, NTIMS offers exceptional sensitivity enabling routine and precise oxygen isotope analysis of sub-microgram samples of PO 4, (<21 nmoles equivalent CO 2 gas) without need for lengthy chemical pre-treatment reproducibility of the sample. Overall external precision is ±1%c (2σ) for 18O/16 O and 170/15O with of instrumental isotope fractionation (calculated from 18O/16O of ±0.5%c amu -1. Small phosphate samples including single mineral grains from meteorites, or apatite microfossils, can be analyzed by this technique.

  19. The Use of Gas Chromatography and Mass Spectrometry to Introduce General Chemistry Students to Percent Mass and Atomic Mass Calculations

    ERIC Educational Resources Information Center

    Pfennig, Brian W.; Schaefer, Amy K.

    2011-01-01

    A general chemistry laboratory experiment is described that introduces students to instrumental analysis using gas chromatography-mass spectrometry (GC-MS), while simultaneously reinforcing the concepts of mass percent and the calculation of atomic mass. Working in small groups, students use the GC to separate and quantify the percent composition…

  20. Fourier Transform Mass Spectrometry: The Transformation of Modern Environmental Analyses

    PubMed Central

    Lim, Lucy; Yan, Fangzhi; Bach, Stephen; Pihakari, Katianna; Klein, David

    2016-01-01

    Unknown compounds in environmental samples are difficult to identify using standard mass spectrometric methods. Fourier transform mass spectrometry (FTMS) has revolutionized how environmental analyses are performed. With its unsurpassed mass accuracy, high resolution and sensitivity, researchers now have a tool for difficult and complex environmental analyses. Two features of FTMS are responsible for changing the face of how complex analyses are accomplished. First is the ability to quickly and with high mass accuracy determine the presence of unknown chemical residues in samples. For years, the field has been limited by mass spectrometric methods that were based on knowing what compounds of interest were. Secondly, by utilizing the high resolution capabilities coupled with the low detection limits of FTMS, analysts also could dilute the sample sufficiently to minimize the ionization changes from varied matrices. PMID:26784175

  1. Fourier Transform Mass Spectrometry: The Transformation of Modern Environmental Analyses.

    PubMed

    Lim, Lucy; Yan, Fangzhi; Bach, Stephen; Pihakari, Katianna; Klein, David

    2016-01-01

    Unknown compounds in environmental samples are difficult to identify using standard mass spectrometric methods. Fourier transform mass spectrometry (FTMS) has revolutionized how environmental analyses are performed. With its unsurpassed mass accuracy, high resolution and sensitivity, researchers now have a tool for difficult and complex environmental analyses. Two features of FTMS are responsible for changing the face of how complex analyses are accomplished. First is the ability to quickly and with high mass accuracy determine the presence of unknown chemical residues in samples. For years, the field has been limited by mass spectrometric methods that were based on knowing what compounds of interest were. Secondly, by utilizing the high resolution capabilities coupled with the low detection limits of FTMS, analysts also could dilute the sample sufficiently to minimize the ionization changes from varied matrices. PMID:26784175

  2. Mass Spectrometry-Based N-Glycomics of Colorectal Cancer

    PubMed Central

    Sethi, Manveen K.; Fanayan, Susan

    2015-01-01

    Colorectal cancer (CRC) is one of the most prevalent cancers worldwide. An increased molecular understanding of the CRC pathology is warranted to gain insights into the underlying molecular and cellular mechanisms of the disease. Altered protein glycosylation patterns are associated with most diseases including malignant transformation. Recent advances in mass spectrometry and bioinformatics have accelerated glycomics research and present a new paradigm for cancer biomarker discovery. Mass spectrometry (MS)-based glycoproteomics and glycomics, therefore, hold considerable promise to improve the discovery of novel biomarkers with utility in disease diagnosis and therapy. This review focuses on the emerging field of glycomics to present a comprehensive review of advances in technologies and their application in studies aimed at discovering novel glycan-based biomarkers. We will also discuss some of the challenges associated with using glycans as biomarkers. PMID:26690136

  3. Applications of liquid chromatography-mass spectrometry for food analysis.

    PubMed

    Di Stefano, Vita; Avellone, Giuseppe; Bongiorno, David; Cunsolo, Vincenzo; Muccilli, Vera; Sforza, Stefano; Dossena, Arnaldo; Drahos, László; Vékey, Károly

    2012-10-12

    HPLC-MS applications in the agrifood sector are among the fastest developing fields in science and industry. The present tutorial mini-review briefly describes this analytical methodology: HPLC, UHPLC, nano-HPLC on one hand, mass spectrometry (MS) and tandem mass spectrometry (MS/MS) on the other hand. Analytical results are grouped together based on the type of chemicals analyzed (lipids, carbohydrates, glycoproteins, vitamins, flavonoids, mycotoxins, pesticides, allergens and food additives). Results are also shown for various types of food (ham, cheese, milk, cereals, olive oil and wines). Although it is not an exhaustive list, it illustrates the main current directions of applications. Finally, one of the most important features, the characterization of food quality (including problems of authentication and adulteration) is discussed, together with a future outlook on future directions. PMID:22560344

  4. Analytical validation of accelerator mass spectrometry for pharmaceutical development

    PubMed Central

    Keck, Bradly D; Ognibene, Ted; Vogel, John S

    2011-01-01

    The validation parameters for pharmaceutical analyses were examined for the accelerator mass spectrometry measurement of 14C/C ratio, independent of chemical separation procedures. The isotope ratio measurement was specific (owing to the 14C label), stable across samples storage conditions for at least 1 year, linear over four orders of magnitude with an analytical range from 0.1 Modern to at least 2000 Modern (instrument specific). Furthermore, accuracy was excellent (between 1 and 3%), while precision expressed as coefficient of variation was between 1 and 6% determined primarily by radiocarbon content and the time spent analyzing a sample. Sensitivity, expressed as LOD and LLOQ was 1 and 10 attomoles of 14C, respectively (which can be expressed as compound equivalents) and for a typical small molecule labeled at 10% incorporated with 14C corresponds to 30 fg equivalents. Accelerator mass spectrometry provides a sensitive, accurate and precise method of measuring drug compounds in biological matrices. PMID:21083256

  5. Current Status and Future Perspectives of Mass Spectrometry Imaging

    PubMed Central

    Nimesh, Surendra; Mohottalage, Susantha; Vincent, Renaud; Kumarathasan, Prem

    2013-01-01

    Mass spectrometry imaging is employed for mapping proteins, lipids and metabolites in biological tissues in a morphological context. Although initially developed as a tool for biomarker discovery by imaging the distribution of protein/peptide in tissue sections, the high sensitivity and molecular specificity of this technique have enabled its application to biomolecules, other than proteins, even in cells, latent finger prints and whole organisms. Relatively simple, with no requirement for labelling, homogenization, extraction or reconstitution, the technique has found a variety of applications in molecular biology, pathology, pharmacology and toxicology. By discriminating the spatial distribution of biomolecules in serial sections of tissues, biomarkers of lesions and the biological responses to stressors or diseases can be better understood in the context of structure and function. In this review, we have discussed the advances in the different aspects of mass spectrometry imaging processes, application towards different disciplines and relevance to the field of toxicology. PMID:23759983

  6. Plasma-based ambient ionization mass spectrometry in bioanalytical sciences.

    PubMed

    Smoluch, Marek; Mielczarek, Przemyslaw; Silberring, Jerzy

    2016-01-01

    Plasma-based ambient ionization mass spectrometry techniques are gaining growing interest due to their specific features, such as the need for little or no sample preparation, its high analysis speed, and the ambient experimental conditions. Samples can be analyzed in gas, liquid, or solid forms. These techniques allow for a wide range of applications, like warfare agent detection, chemical reaction control, mass spectrometry imaging, polymer identification, and food safety monitoring, as well as applications in biomedical science, e.g., drug and pharmaceutical analysis, medical diagnostics, biochemical analysis, etc. Until now, the main drawback of plasma-based techniques is their quantitative aspect, but a lot of efforts have been done to improve this obstacle. PMID:25988731

  7. Mass Spectrometry-Based N-Glycomics of Colorectal Cancer.

    PubMed

    Sethi, Manveen K; Fanayan, Susan

    2015-01-01

    Colorectal cancer (CRC) is one of the most prevalent cancers worldwide. An increased molecular understanding of the CRC pathology is warranted to gain insights into the underlying molecular and cellular mechanisms of the disease. Altered protein glycosylation patterns are associated with most diseases including malignant transformation. Recent advances in mass spectrometry and bioinformatics have accelerated glycomics research and present a new paradigm for cancer biomarker discovery. Mass spectrometry (MS)-based glycoproteomics and glycomics, therefore, hold considerable promise to improve the discovery of novel biomarkers with utility in disease diagnosis and therapy. This review focuses on the emerging field of glycomics to present a comprehensive review of advances in technologies and their application in studies aimed at discovering novel glycan-based biomarkers. We will also discuss some of the challenges associated with using glycans as biomarkers. PMID:26690136

  8. Analysis of tear glucose concentration with electrospray ionization mass spectrometry.

    PubMed

    Taormina, Christopher R; Baca, Justin T; Asher, Sanford A; Grabowski, Joseph J; Finegold, David N

    2007-02-01

    We have developed a mass spectrometry-based method that allows one to accurately determine the glucose concentration of tear fluid. We used a 1 microL micro-capillary to collect tear fluid from the tear meniscus with minimal irritation of the eye. We analyzed the 1 muL volume of collected tear fluid with liquid-chromatography electrospray ionization mass spectrometry with the use of D-glucose-6,6-d2 as an internal standard. Repeated measurements and a recovery experiment on pooled, onion-induced tears showed that the analysis of the glucose in tears was precise (4% relative standard deviation) and provided 100% recovery. We found the tear glucose concentration of one fasting nondiabetic subject to be 13 to 51 microM while the onion-induced tear glucose concentration of a different nondiabetic subject to be 211 to 256 microM. PMID:17084090

  9. Analysis of Tear Glucose Concentration with Electrospray Ionization Mass Spectrometry

    PubMed Central

    Taormina, Christopher R.; Baca, Justin T.; Finegold, David N.; Asher, Sanford A.; Grabowski, Joseph J.

    2007-01-01

    We have developed a mass spectrometry-based method which allows one to accurately determine the glucose concentration of tear fluid. We used a 1 μL micro-capillary to collect tear fluid from the tear meniscus with minimal irritation of the eye. We analyzed the 1 μL volume of collected tear fluid with liquid-chromatography electrospray ionization mass spectrometry with the use of D-glucose-6,6-d2 as an internal standard. Repeated measurements and a recovery experiment on pooled, onion-induced tears showed that the analysis of the glucose in tears was precise (4% relative standard deviation) and provided 100% recovery. We found the tear glucose concentration of one fasting non-diabetic subject to be 13 to 51 μM while the onion-induced tear glucose concentration of a different non-diabetic subject to be 211 to 256 μM. PMID:17084090

  10. Analytical considerations for mass spectrometry profiling in serum biomarker discovery.

    PubMed

    Whiteley, Gordon R; Colantonio, Simona; Sacconi, Andrea; Saul, Richard G

    2009-03-01

    The potential of using mass spectrometry profiling as a diagnostic tool has been demonstrated for a wide variety of diseases. Various cancers and cancer-related diseases have been the focus of much of this work because of both the paucity of good diagnostic markers and the knowledge that early diagnosis is the most powerful weapon in treating cancer. The implementation of mass spectrometry as a routine diagnostic tool has proved to be difficult, however, primarily because of the stringent controls that are required for the method to be reproducible. The method is evolving as a powerful guide to the discovery of biomarkers that could, in turn, be used either individually or in an array or panel of tests for early disease detection. Using proteomic patterns to guide biomarker discovery and the possibility of deployment in the clinical laboratory environment on current instrumentation or in a hybrid technology has the possibility of being the early diagnosis tool that is needed. PMID:19389551

  11. Native Mass Spectrometry in Fragment-Based Drug Discovery.

    PubMed

    Pedro, Liliana; Quinn, Ronald J

    2016-01-01

    The advent of native mass spectrometry (MS) in 1990 led to the development of new mass spectrometry instrumentation and methodologies for the analysis of noncovalent protein-ligand complexes. Native MS has matured to become a fast, simple, highly sensitive and automatable technique with well-established utility for fragment-based drug discovery (FBDD). Native MS has the capability to directly detect weak ligand binding to proteins, to determine stoichiometry, relative or absolute binding affinities and specificities. Native MS can be used to delineate ligand-binding sites, to elucidate mechanisms of cooperativity and to study the thermodynamics of binding. This review highlights key attributes of native MS for FBDD campaigns. PMID:27483215

  12. Investigating quantitation of phosphorylation using MALDI-TOF mass spectrometry

    PubMed Central

    Parker, Laurie; Engel-Hall, Aaron; Drew, Kevin; Steinhardt, George; Helseth, Donald L.; Jabon, David; McMurry, Timothy; Angulo, David S.; Kron, Stephen J.

    2010-01-01

    Despite advances in methods and instrumentation for analysis of phosphopeptides using mass spectrometry, it is still difficult to quantify the extent of phosphorylation of a substrate due to physiochemical differences between unphosphorylated and phosphorylated peptides. Here we report experiments to investigate those differences using MALDI-TOF mass spectrometry for a set of synthetic peptides by creating calibration curves of known input ratios of peptides/phosphopeptides and analyzing their resulting signal intensity ratios. These calibration curves reveal subtleties in sequence-dependent differences for relative desorption/ionization efficiencies that cannot be seen from single-point calibrations. We found that the behaviors were reproducible with a variability of 5–10% for observed phosphopeptide signal. Although these data allow us to begin addressing the issues related to modeling these properties and predicting relative signal strengths for other peptide sequences, it is clear this behavior is highly complex and needs to be further explored. PMID:18064576

  13. Dual Polarity Accurate Mass Calibration for ESI and MALDI Mass Spectrometry Using Maltooligosaccharides

    PubMed Central

    Clowers, Brian H.; Dodds, Eric D.; Seipert, Richard R.; Lebrilla, Carlito B.

    2009-01-01

    In view of the fact that memory effects associated with instrument calibration hinder the use of many m/z and tuning standards, identification of robust, comprehensive, inexpensive, and memory-free calibration standards are of particular interest to the mass spectrometry community. Glucose and its isomers are known to have a residue mass of 162.05282 Da; therefore, both linear and branched forms of poly-hexose oligosaccharides possess well defined masses making them ideal candidates for mass calibration. Using a wide range of maltooligosaccharides (MOS) derived from commercially available beers, ions with m/z ratios from ~500 Da to 2500 Da or more have been observed using Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) and time of flight mass spectrometry (TOF-MS). The mixtures of MOS were further characterized using infrared multiphoton dissociation (IRMPD) and nano-liquid chromatography/mass spectrometry (nano-LC/MS). In addition to providing well defined series of positive and negative calibrant ions using either ESI or MALDI, the MOS are not encumbered by memory effects and are thus well suited mass calibration and instrument tuning standards for carbohydrate analysis. PMID:18655765

  14. Accelerator mass spectrometry for quantitative in vivo tracing

    SciTech Connect

    Vogel, J S

    2005-04-19

    Accelerator mass spectrometry (AMS) counts individual rare, usually radio-, isotopes such as radiocarbon at high efficiency and specificity in milligram-sized samples. AMS traces very low chemical doses ({micro}g) and radiative doses (100 Bq) of isotope labeled compounds in animal models and directly in humans for pharmaceutical, nutritional, or toxicological research. Absorption, metabolism, distribution, binding, and elimination are all quantifiable with high precision after appropriate sample definition.

  15. Characterization of Enterobacteria using MALDI-TOF mass spectrometry.

    PubMed

    Pribil, Patrick; Fenselau, Catherine

    2005-09-15

    A method is proposed for the rapid classification of Gram-negative Enterobacteria using on-slide solubilization and trypsin digestion of proteins, followed by MALDI-TOF MS analysis. Peptides were identified from tryptic digests using microsequencing by tandem mass spectrometry and database searches. Proteins from the outer membrane family (OMP) were consistently identified in the Enterobacteria Escherichia coli, Enterobacter cloacae, Erwinia herbicola, and Salmonella typhimurium. Database searches indicate that these OMP peptides observed are unique to the Enterobacteria order. PMID:16159146

  16. Sheathless interface for coupling capillary electrophoresis with mass spectrometry

    SciTech Connect

    Wang, Chenchen; Tang, Keqi; Smith, Richard D.

    2014-06-17

    A sheathless interface for coupling capillary electrophoresis (CE) with mass spectrometry is disclosed. The sheathless interface includes a separation capillary for performing CE separation and an emitter capillary for electrospray ionization. A portion of the emitter capillary is porous or, alternatively, is coated to form an electrically conductive surface. A section of the emitter capillary is disposed within the separation capillary, forming a joint. A metal tube, containing a conductive liquid, encloses the joint.

  17. Proposal on dynamic correction method for resonance ionization mass spectrometry

    NASA Astrophysics Data System (ADS)

    Noto, Takuma; Tomita, Hideki; Richter, Sven; Schneider, Fabian; Wendt, Klaus; Iguchi, Tetsuo; Kawarabayashi, Jun

    2013-04-01

    For high precision and accuracy in isotopic ratio measurement of transuranic elements using laser ablation assisted resonance ionization mass spectrometry, a dynamic correction method based on correlation of ion signals with energy and timing of each laser pulse was proposed. The feasibility of this dynamic correction method was investigated through the use of a programmable electronics device for fast acquisition of the energy and timing of each laser pulse.

  18. Computational and Statistical Analysis of Protein Mass Spectrometry Data

    PubMed Central

    Noble, William Stafford; MacCoss, Michael J.

    2012-01-01

    High-throughput proteomics experiments involving tandem mass spectrometry produce large volumes of complex data that require sophisticated computational analyses. As such, the field offers many challenges for computational biologists. In this article, we briefly introduce some of the core computational and statistical problems in the field and then describe a variety of outstanding problems that readers of PLoS Computational Biology might be able to help solve. PMID:22291580

  19. Quality management in clinical application of mass spectrometry measurement systems.

    PubMed

    Vogeser, Michael; Seger, Christoph

    2016-09-01

    Thanks to highly specific analyte detection and potentially complete compensation for matrix variables based on the principle of stable isotope derivative internal standardisation, mass spectrometry methods allow the development of diagnostic tests of outstanding analytical quality. However, these features per se do not guarantee reliability of tests. A wide range of factors can introduce analytical errors and inaccuracy due to the extreme complexity of the methods involved. Furthermore, it can be expected that the application patterns of MS methods in diagnostic laboratories will change substantially during the coming years - with presumably less specialised laboratories implementing mass spectrometry. Introduction of highly automated test solutions by manufacturers will require some trade-off between operation convenience, sample throughput and analytical performance. Structured and careful quality and risk management is therefore crucial to translate the analytical power of mass spectrometry into actionable and reliable results for individual patients' care and to maintain the degree of reliability that is expected from MS methods in clinical pathology. This reflection review discusses whether particular quality assurance tools have to be applied for MS-based diagnostic tests and whether these tools are different from those applied for optical- and affinity-based standard tests. Both pre-implementation strategies and surveillance of assays with assessment of metadata in routine testing are addressed. The release of the CLSI guideline C62-A in 2014 was a substantial achievement in this context because it addresses a wide spectrum of relevant issues in quality assurance of mass spectrometry-based clinical tests. However, the translation of this best practice document into individual laboratory settings is likely to be heterogeneous. PMID:27400682

  20. Charge Prediction of Lipid Fragments in Mass Spectrometry

    SciTech Connect

    Schrom, Brian T.; Kangas, Lars J.; Ginovska, Bojana; Metz, Thomas O.; Miller, John H.

    2011-12-18

    An artificial neural network is developed for predicting which fragment is charged and which fragment is neutral for lipid fragment pairs produced from a liquid chromatography tandem mass spectrometry simulation process. This charge predictor is integrated into software developed at PNNL for in silico spectra generation and identification of metabolites known as Met ISIS. To test the effect of including charge prediction in Met ISIS, 46 lipids are used which show a reduction in false positive identifications when the charge predictor is utilized.

  1. Fast liquid chromatography/multiple-stage mass spectrometry of coccidiostats.

    PubMed

    Martínez-Villalba, Anna; Moyano, Encarnación; Galceran, Maria T

    2009-05-01

    Drugs that are used as medicines and also as growth promoters in veterinary care are considered as emerging environmental contaminants and in recent years concern about their potential risk to ecosystems and human health has risen. In this paper we used a method based on liquid chromatography/electrospray tandem mass spectrometry to analyze eight coccidiostatic compounds: diclazuril, dinitrocarbanilide (the main metabolite of nicarbazin), robenidine, lasalocid, monensin, salinomycin, maduramicin and nasarin. Multiple-stage mass spectrometry (MSn) based on the precursor ions [M+Na]+ (polyether ionophores), [M+H]+ (robenidine) and [M-H]- (diclazuril and dinitrocarbanilide) was used to study the fragmentation of these compounds. MSn data and genealogical relationships were used to propose a tentative assignment of the different fragment ions. Loss of water, decarboxylations, ketone beta-cleavages and rearrangement of cyclic ethers and amide groups were some of the fragmentations observed for these compounds. Liquid chromatography with a sub-2 microm particle size column was coupled to tandem mass spectrometry (LC/MS/MS) allowing the separation of these compounds in less than 7 min. Method detection limits ranging from 11 to 71 ng L(-1) and run-to-run values in terms of relative standard deviation (RSD) (up to 12%) were obtained. PMID:19308967

  2. Significant advancement of mass spectrometry imaging for food chemistry.

    PubMed

    Yoshimura, Yukihiro; Goto-Inoue, Naoko; Moriyama, Tatsuya; Zaima, Nobuhiro

    2016-11-01

    Food contains various compounds that have an impact on our daily lives. Many technologies have been established to analyze these molecules of interest in foods. However, the analysis of the spatial distribution of these compounds in foods using conventional technology, such as high-performance liquid chromatography-mass spectrometry or gas chromatography-mass spectrometry is difficult. Matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI) is considered an ideal complementary approach. MALDI-MSI is a two-dimensional MALDI-MS technology that can detect compounds in a tissue section without extraction, purification, separation, or labeling. MALDI-MSI can be used to visualize the spatial distribution of chemical compounds or biomolecules in foods. Although the methodology of MALDI-MSI in food science is not yet fully established, the versatility of MALDI-MSI is expected to open a new frontier in food science. Herein, we describe the principles and applications of MALDI-MSI in food science and related fields. PMID:27211639

  3. Applications of supercritical fluids.

    PubMed

    Brunner, Gerd

    2010-01-01

    This review discusses supercritical fluids in industrial and near-to-industry applications. Supercritical fluids are flexible tools for processing materials. Supercritical fluids have been applied to mass-transfer processes, phase-transition processes, reactive systems, materials-related processes, and nanostructured materials. Some applications are already at industrial capacity, whereas others remain under development. In addition to extraction, application areas include impregnation and cleaning, multistage countercurrent separation, particle formation, coating, and reactive systems such as hydrogenation, biomass gasification, and supercritical water oxidation. Polymers are modified with supercritical fluids, and colloids and emulsions as well as nanostructured materials exhibit interesting phenomena when in contact with supercritical fluids that can be industrially exploited. For these applications to succeed, the properties of supercritical fluids in combination with the materials processed must be clearly determined and fundamental knowledge of the complex behavior must be made readily available. PMID:22432584

  4. Characterization of individual particles in gaseous media by mass spectrometry

    NASA Technical Reports Server (NTRS)

    Sinha, M. P.

    1990-01-01

    An introduction is given to a system for particle analysis by mass spectrometry (PAMS) which employs particle-beam techniques to measure mass spectra on a continuous real-time basis. The system is applied to particles of both organic and inorganic compounds, and the measurements give the chemical characteristics of particles in mixtures and indicate source apportionment. The PAMS system can be used for process control and studying heterogeneous/catalytic reactions in particles, and can be fitted to study the real-time attributes of PAMS.

  5. Tissue MALDI Mass Spectrometry Imaging (MALDI MSI) of Peptides.

    PubMed

    Beine, Birte; Diehl, Hanna C; Meyer, Helmut E; Henkel, Corinna

    2016-01-01

    Matrix assisted laser desorption/ionization mass spectrometry imaging (MALDI MSI) is a technique to visualize molecular features of tissues based on mass detection. This chapter focuses on MALDI MSI of peptides and provides detailed operational instructions for sample preparation of cryoconserved and formalin-fixed paraffin-embedded (FFPE) tissue. Besides sample preparation we provide protocols for the MALDI measurement, tissue staining, and data analysis. On-tissue digestion and matrix application are described for two different commercially available and commonly used spraying devices: the SunCollect (SunChrom) and the ImagePrep (Bruker Daltonik GmbH). PMID:26700046

  6. High Resolution Double-Focusing Isotope Ratio Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Radke, J.; Deerberg, M.; Hilkert, A.; Schlüter, H.-J.; Schwieters, J.

    2012-04-01

    In recent years isotope ratio mass spectrometry has extended to the capability of quantifying very small isotope signatures related with low abundances and simultaneously detecting molecular masses such as isotopomers and isotopologues containing clumped isotopes. Some of those applications are limited by molecular interferences like different gas molecules with the same nominal mass, e.g. Ar/O2, adducts of the same molecule or of different molecules, and very small isotope abundances. The Thermo Scientific MAT 253 ULTRA is the next generation of high precision gas isotope ratio mass spectrometry, which combines a 10 KV gas ionization source (Thermo Scientific MAT 253) with a double focusing multi-collector mass analyzer (Thermo Scientific Neptune) and reduces those limitations by measuring isotope ratios on a larger dynamic range with high precision. Small ion beam requirements and high sensitivity are achieved by signal-to-noise improvements through enhanced ion beam amplification in faraday cups and ion counters. Interfering backgrounds, e.g. interfering isotopologues or isobaric ions of contaminants, are dramatically decreased by a dynamic range increase combined with high evacuation leading to undisturbed ion transmission through the double-focusing analyser. Furthermore, automated gain calibration for mathematical baseline corrections, switchable detector arrays, ion source control, analyser focusing and full data export is controlled under Isodat data control. New reference/sample strategies are under investigation besides incorporation of the continuous-flow technique and its versatile inlet devices. We are presenting first results and applications of the MAT 253 Ultra.

  7. Measurement of the 135Cs half-life with accelerator mass spectrometry and inductively coupled plasma mass spectrometry

    NASA Astrophysics Data System (ADS)

    MacDonald, C. M.; Cornett, R. J.; Charles, C. R. J.; Zhao, X. L.; Kieser, W. E.

    2016-01-01

    The isotope 135Cs is quoted as having a half-life of 2.3 Myr. However, there are three published values ranging from 1.8 to 3 Myr. This research reviews previous measurements and reports a new measurement of the half-life using newly developed accelerator mass spectrometry (AMS) and inductively coupled plasma mass spectrometry (ICPMS) techniques along with β and γ radiometric analysis. The half-life was determined to be (1.6 ±0.6 ) ×106 yr by AMS and (1.3 ±0.2 ) ×106 yr by ICPMS with 95% confidence. The two values agree with each other but differ from the accepted value by ˜40 % .

  8. Two-dimensional liquid chromatography/mass spectrometry/mass spectrometry separation of water-soluble metabolites.

    PubMed

    Fairchild, Jacob N; Horvath, Krisztian; Gooding, Jessica R; Campagna, Shawn R; Guiochon, Georges

    2010-12-24

    Off-line two-dimensional liquid chromatography with tandem mass spectrometry detection (2D-LC/MS-MS) was used to separate a set of metabolomic species. Water-soluble metabolites were extracted from Escherichia coli and Saccharomyces cerevisae cultures and were immediately analyzed using strong cation exchange (SCX)-hydrophilic interaction chromatography (HILIC). Metabolite mixtures are well-suited for multidimensional chromatography as the range of components varies widely with respect to polarity and chemical makeup. Some currently used methods employ two different separations for the detection of positively and negatively ionized metabolites by mass spectrometry. Here we developed a single set of chromatographic conditions for both ionization modes and were able to detect a total of 141 extracted metabolite species, with an overall peak capacity of ca. 2500. We show that a single two-dimensional separation method is sufficient and practical when a pair or more of unidimensional separations are used in metabolomics. PMID:21094946

  9. The use of gas chromatography-mass spectrometry/combustion/isotope ratio mass spectrometry to demonstrate progesterone treatment in bovines.

    PubMed

    Janssens, Geert; Mangelinckx, Sven; Courtheyn, Dirk; De Kimpe, Norbert; Matthijs, Bert; Le Bizec, Bruno

    2016-06-01

    Currently, no analytical method is available to demonstrate progesterone administration in biological samples collected in rearing animals, and therefore, tracking the abuse of this popular growth promoter is arduous. In this study, a method is presented to reveal progesterone (PG) treatment on the basis of carbon isotope measurement of 5β-pregnane-3α, 20α-diol (BAA-PD), a major PG metabolite excreted in bovine urine, by gas chromatography-mass spectrometry/combustion/isotope ratio mass spectrometry (GC-MS/C/IRMS). 5-Androstene-3β,17α-diol (AEdiol) is used as endogenous reference compound. Intermediate precisions (n=11) of 0.56‰ and 0.68‰ have been determined for AEdiol and BAA-PD, respectively. The analytical method was used for the very first time to successfully differentiate urine samples collected in treated and untreated animals. PMID:27157423

  10. Neuropeptide Signaling in Crustaceans Probed by Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Liang, Zhidan

    Neuropeptides are one of the most diverse classes of signaling molecules whose identities and functions are not yet fully understood. They have been implicated in the regulation of a wide range of physiological processes, including feeding-related and motivated behaviors, and also environmental adaptations. In this work, improved mass spectrometry-based analytical platforms were developed and applied to the crustacean systems to characterize signaling molecules. This dissertation begins with a review of mass spectrometry-based neuropeptide studies from both temporal- and spatial-domains. This review is then followed by several chapters detailing a few research projects related to the crustacean neuropeptidomic characterization and comparative analysis. The neuropeptidome of crayfish, Orconectes rusticus is characterized for the first time using mass spectrometry-based tools. In vivo microdialysis sampling technique offers the capability of direct sampling from extracellular space in a time-resolved manner. It is used to investigate the secreted neuropeptide and neurotransmitter content in Jonah crab, Cancer borealis, in this work. A new quantitation strategy using alternative mass spectrometry data acquisition approach is developed and applied for the first time to quantify neuropeptides. Coupling of this method with microdialysis enables the study of neuropeptide dynamics concurrent with different behaviors. Proof-of-principle experiments validating this approach have been carried out in Jonah crab, Cancer borealis to study feeding- and circadian rhythm-related neuropeptide changes using micoridialysis in a time-resolved manner. This permits a close correlation between behavioral and neurochemical changes, providing potential candidates for future validation of regulatory roles. In addition to providing spatial information, mass spectrometry imaging (MSI) technique enables the characterization of signaling molecules while preserving the temporal resolution. A

  11. Lipidomics by Supercritical Fluid Chromatography.

    PubMed

    Laboureur, Laurent; Ollero, Mario; Touboul, David

    2015-01-01

    This review enlightens the role of supercritical fluid chromatography (SFC) in the field of lipid analysis. SFC has been popular in the late 1980s and 1990s before almost disappearing due to the commercial success of liquid chromatography (LC). It is only 20 years later that a regain of interest appeared when new commercial instruments were introduced. As SFC is fully compatible with the injection of extracts in pure organic solvent, this technique is perfectly suitable for lipid analysis and can be coupled with either highly universal (UV or evaporative light scattering) or highly specific (mass spectrometry) detection methods. A short history of the use of supercritical fluids as mobile phase for the separation oflipids will be introduced first. Then, the advantages and drawbacks of SFC are discussed for each class of lipids (fatty acyls, glycerolipids, glycerophospholipids, sphingolipids, sterols, prenols, polyketides) defined by the LIPID MAPS consortium. PMID:26090714

  12. Lipidomics by Supercritical Fluid Chromatography

    PubMed Central

    Laboureur, Laurent; Ollero, Mario; Touboul, David

    2015-01-01

    This review enlightens the role of supercritical fluid chromatography (SFC) in the field of lipid analysis. SFC has been popular in the late 1980s and 1990s before almost disappearing due to the commercial success of liquid chromatography (LC). It is only 20 years later that a regain of interest appeared when new commercial instruments were introduced. As SFC is fully compatible with the injection of extracts in pure organic solvent, this technique is perfectly suitable for lipid analysis and can be coupled with either highly universal (UV or evaporative light scattering) or highly specific (mass spectrometry) detection methods. A short history of the use of supercritical fluids as mobile phase for the separation oflipids will be introduced first. Then, the advantages and drawbacks of SFC are discussed for each class of lipids (fatty acyls, glycerolipids, glycerophospholipids, sphingolipids, sterols, prenols, polyketides) defined by the LIPID MAPS consortium. PMID:26090714

  13. Tandem mass spectrometry and ion mobility mass spectrometry for the analysis of molecular sequence and architecture of hyperbranched glycopolymers

    PubMed Central

    Liu, Xiumin; Cool, Lydia R.; Lin, Kenneth; Kasko, Andrea M.; Wesdemiotis, Chrys

    2015-01-01

    Multidimensional mass spectrometry techniques, combining matrix-assisted laser desorption/ionization (MALDI) or electrospray ionization (ESI) with tandem mass spectrometry (MS2), multistage mass spectrometry (MSn) or ion mobility mass spectrometry (IM-MS), have been employed to gain precise structural insight on the compositions, sequences and architectures of small oligomers of a hyperbranched glycopolymer, prepared by atom transfer radical copolymerization of an acrylate monomer (A) and an acrylate inimer (B), both carrying mannose ester pendants. The MS data confirmed the incorporation of multiple inimer repeat units, which ultimately lead to the hyperbranched material. The various possible structures of n-mers with the same composition were subsequently elucidated based on MS2 and MSn studies. The characteristic elimination of bromomethane molecule provided definitive information about the comonomer connectivity in the copolymeric AB2 trimer and A2B2 tetramer, identifying as present only one of the three possible trimeric isomers (viz. sequence BBA) and only two of the six possible tetrameric isomers (viz. sequences BBA2 and BABA). Complementary IM-MS studies confirmed that only one of the tetrameric structures is formed. Comparison of the experimentally determined collision cross-section of the detected isomer with those predicted by molecular simulations for the two possible sequences ascertained BBA2 as the predominant tetrameric architecture. The multidimensional MS approaches presented provide connectivity information at the atomic level without requiring high product purity (due to the dispersive nature of MS) and, hence, should be particularly useful for the microstructure characterization of novel glycopolymers and other types of complex copolymers. PMID:25519163

  14. Emerging mass spectrometry techniques for the direct analysis of microbial colonies

    PubMed Central

    Fang, Jinshu; Dorrestein, Pieter C.

    2014-01-01

    One of the emerging areas in microbiology is detecting specialized metabolites produced by microbial colonies and communities with mass spectrometry. In this review/perspective, we illustrate the emerging mass spectrometry methodologies that enable the interrogation of specialized metabolites directly from microbial colonies. Mass spectrometry techniques such as imaging mass spectrometry and real-time mass spectrometry allow two and three dimensional visualization of the distribution of metabolites, often with minimal sample pretreatment. The speed in which molecules are captured using these methods requires the development of new molecular visualization tools such as molecular networking. Together, these tools are beginning to provide unprecedented insight into the chemical world that microbes experience. PMID:25064218

  15. Resonance enhanced multiphoton ionization/secondary neutral mass spectrometry and cesium attachment secondary ion mass spectrometry of bronze : a comparison.

    SciTech Connect

    McCann, M. P.; Calaway, W. F.; Pellin, M. J.; Veryovkin, I. V.; Constantinides, I.; Adriaens, A.; Adams, F.; Materials Science Division; Sam Houston State Univ.; Univ. of Antwerp

    2002-05-01

    Archaeologists have considerable interests in ancient bronzes. They want to know how these alloys were produced and how they corroded with time. Modern bronzes, with compositions very close to that of some ancient bronzes, have been produced and two methods were examined to characterize one of these modern bronzes. Analysis of this modern bronze using resonance enhanced multiphoton ionization/secondary neutral mass spectrometry (REMPI/SNMS) is examined in detail and compared to cesium attachment secondary ion mass spectrometry (CsAMS) results. Both REMPI/SNMS and CsAMS were used to quantify the composition of Fe, Ni and Mn in a modern quaternary bronze designed to serve as a certified reference material for an ancient bronze. Both methods exhibit reduced matrix effects when compared to secondary ion mass spectrometry (SIMS) and thus quantification should be simplified. It was found that when relative sensitivity factors obtained from a standard bronze material are used to calibrate the instruments, the REMPI/SNMS measurements yield results that were more sensitive and more accurate.

  16. Plutonium measurements by accelerator mass spectrometry at LLNL

    SciTech Connect

    McAninch, J E; Hamilton, T F; Broan, T A; Jokela, T A; Knezovich, T J; Ognibene, T J; Proctor, I D; Roberts, M L; Southon, J R; Vogel, J S; Sideras-Haddad, E

    1999-10-26

    Mass spectrometric methods provide sensitive, routine, and cost-effective analyses of long-lived radionuclides. Here the authors report on the status of work at Lawrence Livermore National Laboratory (LLNL) to develop a capability for actinide measurements by accelerator mass spectrometry (AMS) to take advantage of the high potential of AMS for rejection of interferences. This work demonstrates that the LLNL AMS spectrometer is well-suited for providing high sensitivity, robust, high throughput measurements of plutonium concentrations and isotope ratios. Present backgrounds are {approximately}2 x 10{sup 7}atoms per sample for environmental samples prepared using standard alpha spectrometry protocols. Recent measurements of {sup 239+240}Pu and {sup 241}Pu activities and {sup 240}Pu/{sup 239}Pu isotope ratios in IAEA reference materials agree well with IAEA reference values and with alpha spectrometry and recently published ICP-MS results. Ongoing upgrades of the AMS spectrometer are expected to reduce backgrounds below 1 x 10{sup 6} atoms per sample while allowing simplifications of the sample preparation chemistry. These simplifications will lead to lower per-sample costs, higher throughput, faster turn around and, ultimately, to larger and more robust data sets.

  17. LESA FAIMS Mass Spectrometry for the Spatial Profiling of Proteins from Tissue.

    PubMed

    Griffiths, Rian L; Creese, Andrew J; Race, Alan M; Bunch, Josephine; Cooper, Helen J

    2016-07-01

    We have shown previously that coupling of high field asymmetric waveform ion mobility spectrometry (FAIMS), also known as differential ion mobility, with liquid extraction surface analysis (LESA) mass spectrometry of tissue results in significant improvements in the resulting protein mass spectra. Here, we demonstrate LESA FAIMS mass spectrometry imaging of proteins in sections of mouse brain and liver tissue. The results are compared with LESA mass spectrometry images obtained in the absence of FAIMS. The results show that the number of different protein species detected can be significantly increased by incorporating FAIMS into the workflow. A total of 34 proteins were detected by LESA FAIMS mass spectrometry imaging of mouse brain, of which 26 were unique to FAIMS, compared with 15 proteins (7 unique) detected by LESA mass spectrometry imaging. A number of proteins were identified including α-globin, 6.8 kDa mitochondrial proteolipid, macrophage migration inhibitory factor, ubiquitin, β-thymosin 4, and calmodulin. A total of 40 species were detected by LESA FAIMS mass spectrometry imaging of mouse liver, of which 29 were unique to FAIMS, compared with 24 proteins (13 unique) detected by LESA mass spectrometry imaging. The spatial distributions of proteins identified in both LESA mass spectrometry imaging and LESA FAIMS mass spectrometry imaging were in good agreement indicating that FAIMS is a suitable tool for inclusion in mass spectrometry imaging workflows. PMID:27228471

  18. Lipidomic mass spectrometry and its application in neuroscience

    PubMed Central

    Enriquez-Algeciras, Mabel; Bhattacharya, Sanjoy K

    2013-01-01

    Central and peripheral nervous systems are lipid rich tissues. Lipids, in the context of lipid-protein complexes, surround neurons and provide electrical insulation for transmission of signals allowing neurons to remain embedded within a conducting environment. Lipids play a key role in vesicle formation and fusion in synapses. They provide means of rapid signaling, cell motility and migration for astrocytes and other cell types that surround and play supporting roles neurons. Unlike many other signaling molecules, lipids are capable of multiple signaling events based on the different fragments generated from a single precursor during each event. Lipidomics, until recently suffered from two major disadvantages: (1) level of expertise required an overwhelming amount of chemical detail to correctly identify a vast number of different lipids which could be close in their chemical reactivity; and (2) high amount of purified compounds needed by analytical techniques to determine their structures. Advances in mass spectrometry have enabled overcoming these two limitations. Mass spectrometry offers a great degree of simplicity in identification and quantification of lipids directly extracted from complex biological mixtures. Mass spectrometers can be regarded to as mass analyzers. There are those that separate and analyze the product ion fragments in space (spatial) and those which separate product ions in time in the same space (temporal). Databases and standardized instrument parameters have further aided the capabilities of the spatial instruments while recent advances in bioinformatics have made the identification and quantification possible using temporal instruments. PMID:24340133

  19. Surface Ionization and Soft Landing Techniques in Mass Spectrometry

    SciTech Connect

    Futrell, Jean H.; Laskin, Julia

    2010-04-01

    The advent of soft ionization techniques, notably electrospray and laser desorption ionization methods, has extended mass spectrometric methods to large molecules and molecular complexes. This both greatly expands appli¬cations of mass spectrometry and makes the activation and dissociation of complex ions an integral part of large molecule mass spectrometry. A corollary of the much greater number of internal degrees of freedom and high density of states associated with molecular complexity is that internal energies much higher than the dissociation energies for competing fragmentation processes are required for observable fragmentation in time scales sampled by mass spectrometers. This article describes the kinetics of surface-induced dissociation (SID), a particularly efficient activation method for complex ions. Two very important characteristics of SID are very rapid, sub-picosecond activation and precise control of ion internal energy by varying ion collision energy. The nature of the surface plays an important role in SID, determining both efficiency and mechanism of ion activation. Surface composition and morphology strongly influence the relative importance of competing reactions of SID, ion capture (soft-landing), surface reaction and neutralization. The important features of SID and ion soft-landing are described briefly in this review and more fully in the recommended reading list.

  20. Ultratrace Analysis of Uranium and Plutonium By Mass Spectrometry

    SciTech Connect

    Wacker, John F.; Wogman, Ned A.; Olsen, Khris B.; Petersen, Steven L.; Farmer, O T.; Kelley, James M.; Eiden, Greg C.; Maiti, Tapas C.

    2003-01-01

    At the Pacific Northwest National Laboratory (PNNL), we have developed highly sensitive methods to analyze uranium and plutonium in environmental samples. The development of an ultratrace analysis capability for measuring uranium and plutonium has arisen from a need to detect and characterize environmental samples for signatures associated with nuclear industry processes. Our most sensitive well-developed methodologies employ thermal ionization mass spectrometry (TIMS), however, recent advances in inductively coupled plasma mass spectrometry (ICP-MS) have shown considerable promise for use in detecting uranium and plutonium at ultratrace levels. The work at PNNL has included the development of both chemical separation and purification techniques, as well as the development of mass spectrometric instrumentation and techniques. At the heart of our methodology for TIMS analysis is a procedure that utilizes 100-microliter-volumes of analyte for chemical processing to purify, separate, and load actinide elements into resin beads for subsequent mass spectrometric analysis. The resin bead technique has been combined with a thorough knowledge of the physicochemistry of thermal ion emission to achieve femtogram detection limits for the TIMS analysis of plutonium in environmental samples.

  1. Study of coal structure using secondary ion mass spectrometry

    SciTech Connect

    Tingey, G.L.; Lytle, J.M.; Baer, D.R.; Thomas, M.T.

    1980-12-01

    Secondary-ion Mass Spectrometry (SIMS) is examined as a tool for studying the chemical structure of coal. SIMS has potential for analysis of coal because of the following characteristics: sensitivity to chemical structure; high sensitivity to all masses; application to solids; excellent depth resolution; and reasonable spatial resolution. SIMS spectra of solid coals show differences with respect to coal rank, the spectra of high rank coal being similar to that of graphite, and the spectra of low rank coal being similar to that of wood. Some functional group analysis is also possible using SIMS. Low rank coals show a larger peak at 15 amu indicating more methyl groups than found in the higher rank coals. Fragments with two and three carbon atoms have also been examined; much larger fragments are undoubtedly present but were not evaluated in this study. Examination of these groups, which are expected to contain valuable information on coal structure, is planned for future work. It has been observed that mineral atoms present in the coal have large secondary ion yields which complicate the interpretation of the spectra. Studies on mineral-free coals and model compounds are therefore recommended to facilitate determination of organic coal structure. In addition, mass spectrometry with much greater mass resolution will aid in distinguishing between various ion species.

  2. Exploring the high-mass components of humic acid by laser desorption ionization mass spectrometry.

    PubMed

    Chilom, Gabriela; Chilom, Ovidiu; Rice, James A

    2008-05-01

    Leonardite and Elliot soil humic acids have been analyzed by laser desorption ionization mass spectrometry (LDI MS) in the m/z 4000-200,000 range. Positive ion mass spectra for each humic acid obtained under optimum conditions showed a broad high-mass distribution between m/z 20,000 and 80,000. The dependence of the mass distribution on instrumental parameters and solution conditions was used to investigate the nature of the high-mass peaks from humic acid spectra. Our data suggests that macromolecular ions and humic acid aggregates have the same probability of occurrence while cluster ion formation has a low probability of occurrence. PMID:18421699

  3. Ion-molecule adduct formation in tandem mass spectrometry.

    PubMed

    Alechaga, Élida; Moyano, Encarnación; Galceran, Maria Teresa

    2016-02-01

    Nowadays most LC-MS methods rely on tandem mass spectrometry not only for quantitation and confirmation of compounds by multiple reaction monitoring (MRM), but also for the identification of unknowns from their product ion spectra. However, gas-phase reactions between charged and neutral species inside the mass analyzer can occur, yielding product ions at m/z values higher than that of the precursor ion, or at m/z values difficult to explain by logical losses, which complicate mass spectral interpretation. In this work, the formation of adduct ions in the mass analyzer was studied using several mass spectrometers with different mass analyzers (ion trap, triple quadrupole, and quadrupole-Orbitrap). Heterocyclic amines (AαC, MeAαC, Trp-P-1, and Trp-P-2), photo-initiators (BP and THBP), and pharmaceuticals (phenacetin and levamisole) were selected as model compounds and infused in LCQ Classic, TSQ Quantum Ultra AM, and Q-Exactive Orbitrap (ThermoFisher Scientific) mass spectrometers using electrospray as ionization method. The generation of ion-molecule adducts depended on the compound and also on the instrument employed. Adducts with neutral organic solvents (methanol and acetonitrile) were only observed in the ion trap instrument (LCQ Classic), because of the ionization source on-axis configuration and the lack of gas-phase barriers, which allowed inertial entrance of the neutrals into the analyzer. Adduct formation (only with water) in the triple quadrupole instruments was less abundant than in the ion trap and quadrupole-Orbitrap mass spectrometers, because of the lower residence time of the reactive product ions in the mass analyzer. The moisture level of the CID and/or damper gas had a great effect in beam-like mass analyzers such as triple quadrupole, but not in trap-like mass analyzers, probably because of the long residence time that allowed adduct formation even with very low concentrations of water inside the mass spectrometer. PMID:26700446

  4. Intact MicroRNA Analysis Using High Resolution Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Kullolli, Majlinda; Knouf, Emily; Arampatzidou, Maria; Tewari, Muneesh; Pitteri, Sharon J.

    2014-01-01

    MicroRNAs (miRNAs) are small single-stranded non-coding RNAs that post-transcriptionally regulate gene expression, and play key roles in the regulation of a variety of cellular processes and in disease. New tools to analyze miRNAs will add understanding of the physiological origins and biological functions of this class of molecules. In this study, we investigate the utility of high resolution mass spectrometry for the analysis of miRNAs through proof-of-concept experiments. We demonstrate the ability of mass spectrometry to resolve and separate miRNAs and corresponding 3' variants in mixtures. The mass accuracy of the monoisotopic deprotonated peaks from various miRNAs is in the low ppm range. We compare fragmentation of miRNA by collision-induced dissociation (CID) and by higher-energy collisional dissociation (HCD) which yields similar sequence coverage from both methods but additional fragmentation by HCD versus CID. We measure the linear dynamic range, limit of detection, and limit of quantitation of miRNA loaded onto a C18 column. Lastly, we explore the use of data-dependent acquisition of MS/MS spectra of miRNA during online LC-MS and demonstrate that multiple charge states can be fragmented, yielding nearly full sequence coverage of miRNA on a chromatographic time scale. We conclude that high resolution mass spectrometry allows the separation and measurement of miRNAs in mixtures and a standard LC-MS setup can be adapted for online analysis of these molecules.

  5. Constraining Anthropogenic and Biogenic Emissions Using Chemical Ionization Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Spencer, Kathleen M.

    Numerous gas-phase anthropogenic and biogenic compounds are emitted into the atmosphere. These gases undergo oxidation to form other gas-phase species and particulate matter. Whether directly or indirectly, primary pollutants, secondary gas-phase products, and particulate matter all pose health and environmental risks. In this work, ambient measurements conducted using chemical ionization mass spectrometry are used as a tool for investigating regional air quality. Ambient measurements of peroxynitric acid (HO2NO2) were conducted in Mexico City. A method of inferring the rate of ozone production, PO3, is developed based on observations of HO2NO 2, NO, and NO2. Comparison of this observationally based PO3 to a highly constrained photochemical box model indicates that regulations aimed at reducing ozone levels in Mexico City by reducing NOx concentrations may be effective at higher NO x levels than predicted using accepted photochemistry. Measurements of SO2 and particulate sulfate were conducted over the Los Angeles basin in 2008 and are compared to measurements made in 2002. A large decrease in SO2 concentration and a change in spatial distribution are observed. Nevertheless, only a modest reduction in sulfate concentration is observed at ground sites within the basin. Possible explanations for these trends are investigated. Two techniques, single and triple quadrupole chemical ionization mass spectrometry, were used to quantify ambient concentrations of biogenic oxidation products, hydroxyacetone and glycolaldehyde. The use of these techniques demonstrates the advantage of triple quadrupole mass spectrometry for separation of mass analogues, provided the collision-induced daughter ions are sufficiently distinct. Enhancement ratios of hydroxyacetone and glycolaldehyde in Californian biomass burning plumes are presented as are concentrations of these compounds at a rural ground site downwind of Sacramento.

  6. Probing Bunyavirus N protein oligomerisation using mass spectrometry

    PubMed Central

    Shepherd, Dale A; Ariza, Antonio; Edwards, Thomas A; Barr, John N; Stonehouse, Nicola J; Ashcroft, Alison E

    2014-01-01

    RATIONALE Bunyaviruses have become a major threat to both humans and livestock in Europe and the Americas. The nucleocapsid (N) protein of these viruses is key to the replication cycle and knowledge of the N oligomerisation state is central to understanding the viral lifecycle and for development of therapeutic strategies. METHODS Bunyamwera virus and Schmallenberg virus N proteins (BUNV-N and SBV-N) were expressed recombinantly in E. coli as hexahistidine-SUMO-tagged fusions, and the tag removed subsequently. Noncovalent nano-electrospray ionisation mass spectrometry was conducted in the presence and absence of short RNA oligonucleotides. Instrumental conditions were optimised for the transmission of intact protein complexes into the gas phase. The resulting protein-protein and protein-RNA complexes were identified and their stoichiometries verified by their mass. Collision-induced dissociation tandem mass spectrometry was used in cases of ambiguity. RESULTS Both BUNV-N and SBV-N proteins reassembled into N-RNA complexes in the presence of RNA; however, SBV-N formed a wider range of complexes with varying oligomeric states. The N:RNA oligomers observed were consistent with a model of assembly via stepwise addition of N proteins. Furthermore, upon mixing the two proteins in the presence of RNA no heteromeric complexes were observed, thus revealing insights into the specificity of oligomerisation. CONCLUSIONS Noncovalent mass spectrometry has provided the first detailed analysis of the co-populated oligomeric species formed by these important viral proteins and revealed insights into their assembly pathways. Using this technique has also enabled comparisons to be made between the two N proteins. PMID:24573811

  7. Comparison of thermal ionization mass spectrometry and Multiple Collector Inductively Coupled Plasma Mass Spectrometry for cesium isotope ratio measurements

    NASA Astrophysics Data System (ADS)

    Isnard, H.; Granet, M.; Caussignac, C.; Ducarme, E.; Nonell, A.; Tran, B.; Chartier, F.

    2009-11-01

    In the nuclear domain, precise and accurate isotopic composition determination of elements in spent nuclear fuels is mandatory to validate neutron calculation codes and for nuclear waste disposal. The present study presents the results obtained on Cs isotope ratio by mass spectrometric measurements. Natural cesium is monoisotopic ( 133Cs) whereas cesium in spent fuels has 4 isotopes ( 133Cs, 134Cs, 135Cs, and 137Cs). As no standard reference material is available to evaluate the accuracy of Cs isotopic measurements, a comparison of cesium isotopic composition in spent nuclear fuels has been performed between Thermal Ionization Mass Spectrometry (TIMS) and a new method involving Multiple Collector Inductively Coupled Plasma Mass Spectrometry (MC-ICPMS) measurements. For TIMS measurements, isotopic fractionation has been evaluated by studying the behavior of cesium isotope ratios ( 133Cs/ 137Cs and 135Cs/ 137Cs) during the analyses. For MC-ICPMS measurements, the mass bias effects have been corrected with an external mass bias correction using elements (Eu and Sb) close to cesium masses. The results obtained by the two techniques show good agreement: relative difference on 133Cs/ 137Cs and 135Cs/ 137Cs ratios for two nuclear samples, analyzed after chemical separation, ranges from 0.2% to 0.5% depending on the choice of reference value for mass bias correction by MC-ICPMS. Finally the quantification of the 135Cs/ 238U ratio by the isotope dilution technique is presented in the case of a MOx (mixed oxide) spent fuel sample. Evaluation of the global uncertainties shows that this ratio could be defined at an uncertainty of 0.5% ( k = 2). The intercomparison between two independent mass spectrometric techniques is fundamental for the evaluation of uncertainty when no isotopic standard is available.

  8. Apparatus for studying premixed laminar flames using mass spectrometry and fiber-optic spectrometry

    NASA Astrophysics Data System (ADS)

    Olsson, Jim O.; Andersson, Lars L.; Lenner, Magnus; Simonson, Margaret

    1990-03-01

    An integrated flat-flame/ microprobe sampling quadrupole mass spectrometer system, complemented by optical spectrometry based on optical fibers, is presented. The short microprobe sampling line (total 25 cm) is directly connected to an open ion source closely flanked by two nude cryopumps (900 l/s) yielding a background pressure of 10-9 Torr and a sampling pressure of about 10-5 Torr. Due to this improved microprobe system, mass spectrometry can be used for analysis of stable species (including fuel, O2, H2O, CO2, CO, and Ar) with less disturbance of the sample than with a conventional microprobe with a back pressure of about 1 Torr. Optical spectrometry is used for the study of emission from important radical species (such as C2, CH, and OH). The system is proposed as a complement to more conventional flat-flame/MBMS systems in which the sampling cone can effect the experimental system. Details are provided concerning the configuration of the whole system ranging from gas delivery to data evaluation. Test data are presented for a 16% methanol/68% oxygen/16% argon flame studied at a pressure of 40 Torr, to elucidate the special features of this system.

  9. Accelerator mass spectrometry at the University of North Texas

    NASA Astrophysics Data System (ADS)

    Anthony, J. M.; Matteson, S.; McDaniel, F. D.; Duggan, J. L.

    1989-04-01

    An accelerator mass spectrometry system designed for analysis of electronic materials is being developed and installed on the University of North Texas 3 MV tandem accelerator (National Electrostatics Corporation 9-SDH). High-resolution magnetic (40° deflection, {M}/{ΔM ≈ 350}, maximum mass-energy product 69 MeVu) and electro static (45 ° deflection, E/ q of 4.8 MeV, {E}/{ΔE}≈ 730 ) analysis, coupled with a 1.5 m time-of-flight path and total energy detection (surface barrier detector) forms the basis of the detection system. In order to provide stable element detection capability at the parts-per-trillion level in electronic materials (Si, GaAs, HgCdTe), a custom ion source, incorporating mass analysis of the sputtering beam, ultraclean slits, low cross-contamination and UHV capability, is being constructed.

  10. Mass spectrometry technology at the Jet Propulsion Laboratory (JPL)

    NASA Technical Reports Server (NTRS)

    Giffin, C. E.

    1985-01-01

    Recent developments in the field of mass spectrometry taking place at the Caltech Jet Propulsion Laboratory are highlighted. The pertinent research and development is aimed at producing an ultrahigh sensitivity mass spectrograph for both spaceflight and terrestrial applications. The unique aspect of the JPL developed technology is an integrating focal plane ion detector that obviates the need for spectral scanning since all ions over a wide mass range are monitored simultaneously. The ion detector utilizes electro-optical technology and is therefore referred to as an Electro-Optical Ion Detector (EOID). A technical description of the JPL MS/EOID, some of the current applications, and its potential benefits for internal contamination analysis are discussed.

  11. Revealing Higher Order Protein Structure Using Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Chait, Brian T.; Cadene, Martine; Olinares, Paul Dominic; Rout, Michael P.; Shi, Yi

    2016-04-01

    The development of rapid, sensitive, and accurate mass spectrometric methods for measuring peptides, proteins, and even intact protein assemblies has made mass spectrometry (MS) an extraordinarily enabling tool for structural biology. Here, we provide a personal perspective of the increasingly useful role that mass spectrometric techniques are exerting during the elucidation of higher order protein structures. Areas covered in this brief perspective include MS as an enabling tool for the high resolution structural biologist, for compositional analysis of endogenous protein complexes, for stoichiometry determination, as well as for integrated approaches for the structural elucidation of protein complexes. We conclude with a vision for the future role of MS-based techniques in the development of a multi-scale molecular microscope.

  12. Revealing Higher Order Protein Structure Using Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Chait, Brian T.; Cadene, Martine; Olinares, Paul Dominic; Rout, Michael P.; Shi, Yi

    2016-06-01

    The development of rapid, sensitive, and accurate mass spectrometric methods for measuring peptides, proteins, and even intact protein assemblies has made mass spectrometry (MS) an extraordinarily enabling tool for structural biology. Here, we provide a personal perspective of the increasingly useful role that mass spectrometric techniques are exerting during the elucidation of higher order protein structures. Areas covered in this brief perspective include MS as an enabling tool for the high resolution structural biologist, for compositional analysis of endogenous protein complexes, for stoichiometry determination, as well as for integrated approaches for the structural elucidation of protein complexes. We conclude with a vision for the future role of MS-based techniques in the development of a multi-scale molecular microscope.

  13. Revealing Higher Order Protein Structure Using Mass Spectrometry.

    PubMed

    Chait, Brian T; Cadene, Martine; Olinares, Paul Dominic; Rout, Michael P; Shi, Yi

    2016-06-01

    The development of rapid, sensitive, and accurate mass spectrometric methods for measuring peptides, proteins, and even intact protein assemblies has made mass spectrometry (MS) an extraordinarily enabling tool for structural biology. Here, we provide a personal perspective of the increasingly useful role that mass spectrometric techniques are exerting during the elucidation of higher order protein structures. Areas covered in this brief perspective include MS as an enabling tool for the high resolution structural biologist, for compositional analysis of endogenous protein complexes, for stoichiometry determination, as well as for integrated approaches for the structural elucidation of protein complexes. We conclude with a vision for the future role of MS-based techniques in the development of a multi-scale molecular microscope. Graphical Abstract ᅟ. PMID:27080007

  14. Analysis of methaqualone in biological matrices by micellar electrokinetic capillary chromatography. Comparison with gas chromatography-mass spectrometry.

    PubMed

    Plaut, O; Girod, C; Staub, C

    1998-04-01

    The analysis of methaqualone (MTQ) in biological matrices by capillary electrophoresis (CE) is described. This methods uses liquid-liquid extraction and micellar electrokinetic capillary chromatography (MECC), an operation mode of CE. Separations are made using a 25 cm long capillary and a borate/phosphate buffer at pH 8.2. Using gas chromatography with mass spectrometry detection (GC-MS) as reference method, MTQ has been analyzed in urine, blood, gastric content and hair. For hair analysis, supercritical fluid extraction was compared with liquid-liquid extraction. Linearity was established in urine and blood between 0.25 and 10.0 micrograms/ml. MTQ recovery from blood was estimated at 60%. The limit of detection of this method in urine is about 0.10 microgram/ml. Drawbacks and advantages of MECC over GC-MS are discussed. PMID:9627981

  15. Identification and quantification of cannabinoids in Cannabis sativa L. plants by high performance liquid chromatography-mass spectrometry.

    PubMed

    Aizpurua-Olaizola, Oier; Omar, Jone; Navarro, Patricia; Olivares, Maitane; Etxebarria, Nestor; Usobiaga, Aresatz

    2014-11-01

    High performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) has been successfully applied to cannabis plant extracts in order to identify cannabinoid compounds after their quantitative isolation by means of supercritical fluid extraction (SFE). MS conditions were optimized by means of a central composite design (CCD) approach, and the analysis method was fully validated. Six major cannabinoids [tetrahydrocannabinolic acid (THCA), tetrahydrocannabinol (THC), cannabidiol (CBD), tetrahydrocannabivarin (THCV), cannabigerol (CBG), and cannabinol (CBN)] were quantified (RSD < 10%), and seven more cannabinoids were identified and verified by means of a liquid chromatograph coupled to a quadrupole-time-of-flight (Q-ToF) detector. Finally, based on the distribution of the analyzed cannabinoids in 30 Cannabis sativa L. plant varieties and the principal component analysis (PCA) of the resulting data, a clear difference was observed between outdoor and indoor grown plants, which was attributed to a higher concentration of THC, CBN, and CBD in outdoor grown plants. PMID:25338935

  16. Advanced analytical techniques for the extraction and characterization of plant-derived essential oils by gas chromatography with mass spectrometry.

    PubMed

    Waseem, Rabia; Low, Kah Hin

    2015-02-01

    In recent years, essential oils have received a growing interest because of the positive health effects of their novel characteristics such as antibacterial, antifungal, and antioxidant activities. For the extraction of plant-derived essential oils, there is the need of advanced analytical techniques and innovative methodologies. An exhaustive study of hydrodistillation, supercritical fluid extraction, ultrasound- and microwave-assisted extraction, solid-phase microextraction, pressurized liquid extraction, pressurized hot water extraction, liquid-liquid extraction, liquid-phase microextraction, matrix solid-phase dispersion, and gas chromatography (one- and two-dimensional) hyphenated with mass spectrometry for the extraction through various plant species and analysis of essential oils has been provided in this review. Essential oils are composed of mainly terpenes and terpenoids with low-molecular-weight aromatic and aliphatic constituents that are particularly important for public health. PMID:25403494

  17. Two-Dimensional Aperture Coding for Magnetic Sector Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Russell, Zachary E.; Chen, Evan X.; Amsden, Jason J.; Wolter, Scott D.; Danell, Ryan M.; Parker, Charles B.; Stoner, Brian R.; Gehm, Michael E.; Brady, David J.; Glass, Jeffrey T.

    2015-02-01

    In mass spectrometer design, there has been a historic belief that there exists a fundamental trade-off between instrument size, throughput, and resolution. When miniaturizing a traditional system, performance loss in either resolution or throughput would be expected. However, in optical spectroscopy, both one-dimensional (1D) and two-dimensional (2D) aperture coding have been used for many years to break a similar trade-off. To provide a viable path to miniaturization for harsh environment field applications, we are investigating similar concepts in sector mass spectrometry. Recently, we demonstrated the viability of 1D aperture coding and here we provide a first investigation of 2D coding. In coded optical spectroscopy, 2D coding is preferred because of increased measurement diversity for improved conditioning and robustness of the result. To investigate its viability in mass spectrometry, analytes of argon, acetone, and ethanol were detected using a custom 90-degree magnetic sector mass spectrometer incorporating 2D coded apertures. We developed a mathematical forward model and reconstruction algorithm to successfully reconstruct the mass spectra from the 2D spatially coded ion positions. This 2D coding enabled a 3.5× throughput increase with minimal decrease in resolution. Several challenges were overcome in the mass spectrometer design to enable this coding, including the need for large uniform ion flux, a wide gap magnetic sector that maintains field uniformity, and a high resolution 2D detection system for ion imaging. Furthermore, micro-fabricated 2D coded apertures incorporating support structures were developed to provide a viable design that allowed ion transmission through the open elements of the code.

  18. Two-dimensional aperture coding for magnetic sector mass spectrometry.

    PubMed

    Russell, Zachary E; Chen, Evan X; Amsden, Jason J; Wolter, Scott D; Danell, Ryan M; Parker, Charles B; Stoner, Brian R; Gehm, Michael E; Brady, David J; Glass, Jeffrey T

    2015-02-01

    In mass spectrometer design, there has been a historic belief that there exists a fundamental trade-off between instrument size, throughput, and resolution. When miniaturizing a traditional system, performance loss in either resolution or throughput would be expected. However, in optical spectroscopy, both one-dimensional (1D) and two-dimensional (2D) aperture coding have been used for many years to break a similar trade-off. To provide a viable path to miniaturization for harsh environment field applications, we are investigating similar concepts in sector mass spectrometry. Recently, we demonstrated the viability of 1D aperture coding and here we provide a first investigation of 2D coding. In coded optical spectroscopy, 2D coding is preferred because of increased measurement diversity for improved conditioning and robustness of the result. To investigate its viability in mass spectrometry, analytes of argon, acetone, and ethanol were detected using a custom 90-degree magnetic sector mass spectrometer incorporating 2D coded apertures. We developed a mathematical forward model and reconstruction algorithm to successfully reconstruct the mass spectra from the 2D spatially coded ion positions. This 2D coding enabled a 3.5× throughput increase with minimal decrease in resolution. Several challenges were overcome in the mass spectrometer design to enable this coding, including the need for large uniform ion flux, a wide gap magnetic sector that maintains field uniformity, and a high resolution 2D detection system for ion imaging. Furthermore, micro-fabricated 2D coded apertures incorporating support structures were developed to provide a viable design that allowed ion transmission through the open elements of the code. PMID:25510933

  19. Identification of Fatty Acids, Phospholipids, and Their Oxidation Products Using Matrix-Assisted Laser Desorption Ionization Mass Spectrometry and Electrospray Ionization Mass Spectrometry

    ERIC Educational Resources Information Center

    Harmon, Christopher W.; Mang, Stephen A.; Greaves, John; Finlayson-Pitts, Barbara J.

    2010-01-01

    Electrospray ionization mass spectrometry (ESI-MS) and matrix-assisted laser desorption ionization mass spectrometry (MALDI-MS) have found increasing application in the analysis of biological samples. Using these techniques to solve problems in analytical chemistry should be an essential component of the training of undergraduate chemists. We…

  20. The role of mass spectrometry in atomic weight determinations.

    PubMed

    De Laeter, John R

    2009-01-01

    The 1914 Nobel Prize for Chemistry was awarded to Theodore Richards, whose work provided an insight into the history of the birth and evolution of matter as embedded in the atomic weights. However, the secret to unlocking the hieroglyphics contained in the atomic weights is revealed by a study of the relative abundances of the isotopes. A consistent set of internationally accepted atomic weights has been a goal of the scientific community for over a century. Atomic weights were originally determined by chemical stoichiometry--the so-called "Harvard Method," but this methodology has now been superseded by the "physical method," in which the isotopic composition and atomic masses of the isotopes comprising an element are used to calculate the atomic weight with far greater accuracy than before. The role of mass spectrometry in atomic weight determinations was initiated by the discovery of isotopes by Thomson, and established by the pioneering work of Aston, Dempster, and Nier using sophisticated mass spectrographs. The advent of the sector field mass spectrometer in 1947, revolutionized the application of mass spectrometry for both solids and gases to other fields of science including atomic weights. Subsequently, technological advances in mass spectrometry have enabled atomic masses to be determined with an accuracy better than one part in 10(7), whilst the absolute isotopic composition of many elements has been determined to produce accurate values of their atomic weights. Conversely, those same technological developments have revealed significant variations in the isotope abundances of many elements caused by a variety of physiochemical mechanisms in natural materials. Although these variations were initially seen as an impediment to the accuracy with which atomic weights could be determined, it was quickly realized that nature had provided a new tool to investigate physiochemical and biogeochemical mechanisms in nature, which could be exploited by precise and

  1. Uncovering biologically significant lipid isomers with liquid chromatography, ion mobility spectrometry and mass spectrometry.

    PubMed

    Kyle, Jennifer E; Zhang, Xing; Weitz, Karl K; Monroe, Matthew E; Ibrahim, Yehia M; Moore, Ronald J; Cha, Jeeyeon; Sun, Xiaofei; Lovelace, Erica S; Wagoner, Jessica; Polyak, Stephen J; Metz, Thomas O; Dey, Sudhansu K; Smith, Richard D; Burnum-Johnson, Kristin E; Baker, Erin S

    2016-02-15

    Understanding how biological molecules are generated, metabolized and eliminated in living systems is important for interpreting processes such as immune response and disease pathology. While genomic and proteomic studies have provided vast amounts of information over the last several decades, interest in lipidomics has also grown due to improved analytical technologies revealing altered lipid metabolism in type 2 diabetes, cancer, and lipid storage disease. Mass spectrometry (MS) measurements are currently the dominant approach for characterizing the lipidome by providing detailed information on the spatial and temporal composition of lipids. However, interpreting lipids' biological roles is challenging due to the existence of numerous structural and stereoisomers (i.e. distinct acyl chain and double-bond positions), which are often unresolvable using present approaches. Here we show that combining liquid chromatography (LC) and structurally-based ion mobility spectrometry (IMS) measurement with MS analyses distinguishes lipid isomers and allows insight into biological and disease processes. PMID:26734689

  2. Rapid Analysis of Isobaric Exogenous Metabolites by Differential Mobility Spectrometry Mass Spectrometry

    SciTech Connect

    Parson, Whitney B; Schneider, Bradley B; Kertesz, Vilmos; Corr, Jay; Covey, Thomas R.; Van Berkel, Gary J

    2011-01-01

    The direct separation of isobaric glucuronide metabolites from propranolol dosed tissue extracts by differential mobility spectrometry mass spectrometry (DMS-MS) with the use of a polar gas-phase chemical modifier was demonstrated. The DMS gas-phase separation was able to resolve the isobaric metabolites with separation times on the order of ms instead of mins to hrs typically required when using pre-ionization chromatographic separation methods. Direct separation of isobaric metabolites from the complex tissue extract was validated using standards as well as implementing an HPLC separation prior to the DMS-MS analysis to pre-separate the species of interest. The ability to separate isobaric exogenous metabolites directly from a complex tissue extract is expected to facilitate the drug development process by increasing analytical throughput without the requirement for pre-ionization cleanup or separation strategies.

  3. Uncovering biologically significant lipid isomers with liquid chromatography, ion mobility spectrometry and mass spectrometry

    SciTech Connect

    Kyle, Jennifer E.; Zhang, Xing; Weitz, Karl K.; Monroe, Matthew E.; Ibrahim, Yehia M.; Moore, Ronald J.; Cha, Jeeyeon; Sun, Xiaofei; Lovelace, Erica S.; Wagoner, Jessica; Polyak, Stephen J.; Metz, Thomas O.; Dey, Sudhansu K.; Smith, Richard D.; Burnum-Johnson, Kristin E.; Baker, Erin S.

    2016-01-01

    Understanding how biological molecules are generated, metabolized and eliminated in living systems is important for interpreting processes such as immune response and disease pathology. While genomic and proteomic studies have provided vast amounts of information over the last several decades, interest in lipidomics has also grown due to improved analytical technologies revealing altered lipid metabolism in type 2 diabetes, cancer, and lipid storage disease. Liquid chromatography and mass spectrometry (LC-MS) measurements are currently the dominant approach for characterizing the lipidome by providing detailed information on the spatial and temporal composition of lipids. However, interpreting lipids’ biological roles is challenging due to the existence of numerous structural and stereoisomers (i.e. distinct acyl chain and double-bond positions), which are unresolvable using present LC-MS approaches. Here we show that combining structurally-based ion mobility spectrometry (IMS) with LC-MS measurements distinguishes lipid isomers and allows insight into biological and disease processes.

  4. Resonance ionization mass spectrometry for isotopic abundance measurements

    NASA Technical Reports Server (NTRS)

    Miller, C. M.

    1986-01-01

    Resonance ionization mass spectrometry (RIMS) is a relatively new laser-based technique for the determination of isotopic abundances. The resonance ionization process depends upon the stepwise absorption of photons from the laser, promoting atoms of the element of interest through progressively higher electronic states until an ion is formed. Sensitivity arises from the efficiency of the resonant absorption process when coupled with the power available from commercial laser sources. Selectivity derives naturally from the distinct electronic structure of different elements. This isobaric discrimination has provided the major impetus for development of the technique. Resonance ionization mass spectrometry was used for analysis of the isotopic abundances of the rare earth lutetium. Isobaric interferences from ytterbium severely effect the ability to measure small amounts of the neutron-deficient Lu isotopes by conventional mass spectrometric techniques. Resonance ionization for lutetium is performed using a continuous-wave laser operating at 452 nm, through a sequential two-photon process, with one photon exciting the intermediate resonance and the second photon causing ionization. Ion yields for microgram-sized quantities of lutetium lie between 10(6) and 10(7) ions per second, at overall ionization efficiencies approaching 10(-4). Discrimination factors against ytterbium greater than 10(6) have been measured. Resonance ionization for technetium is also being explored, again in response to an isobaric interference, molybdenum. Because of the relatively high ionization potential for Tc, three-photon, two-color RIMS processes are being developed.

  5. Atmospheric pressure infrared MALDI imaging mass spectrometry for plant metabolomics.

    PubMed

    Li, Yue; Shrestha, Bindesh; Vertes, Akos

    2008-01-15

    The utility of atmospheric pressure infrared MALDI mass spectrometry (AP IR-MALDI) was assessed for plant metabolomics studies. Tissue sections from plant organs, including flowers, ovaries, aggregate fruits, fruits, leaves, tubers, bulbs, and seeds were studied in both positive and negative ion modes. For leaves, single laser pulses sampled the cuticle and upper epidermal cells, whereas multiple pulses were demonstrated to ablate some mesophyll layers. Tandem mass spectra were obtained with collision-activated dissociation to aid with the identification of some observed ions. In the positive mode, most ions were produced as potassium, proton, or sometimes sodium ion adducts, whereas proton loss was dominant in the negative ion mode. Over 50 small metabolites and various lipids were detected in the spectra including, for example, 7 of the 10 intermediates in the citric acid cycle. Key components of the glycolysis pathway occurring in the plant cytosol were found along with intermediates of phospholipid biosynthesis and reactants or products of amino acid, nucleotide, oligosaccharide, and flavonoid biosynthesis. AP IR-MALDI mass spectrometry was used to follow the fluid transport driven by transpiration and image the spatial distributions of several metabolites in a white lily (Lilium candidum) flower petal. PMID:18088102

  6. Accelerator mass spectrometry for measurement of long-lived radioisotopes

    SciTech Connect

    Elmore, D.; Phillips, F.M.

    1987-05-01

    Particle accelerators, such as those built for research in nuclear physics, can also be used together with magnetic and electrostatic mass analyzers to measure rare isotopes at very low abundance ratios. All molecular ions can be eliminated when accelerated to energies of millions of electron volts. Some atomic isobars can be eliminated with the use of negative ions; others can be separated at high energies by measuring their rate of energy loss in a detector. The long-lived radioisotopes /sup 10/Be, /sup 14/C, /sup 26/Al, /sup 36/Cl, and /sup 129/I can now be measured in small natural samples having isotopic abundances in the range 10/sup -12/ to 10/sup -15/ and as few as 10/sup 5/ atoms. In the past few years, research applications of accelerator mass spectrometry have been concentrated in the earth sciences (climatology, cosmochemistry, environmental chemistry, geochronology, glaciology, hydrology, igneous petrogenesis, minerals exploration, sedimentology, and volcanology), in anthropology and archaeology (radiocarbon dating), and in physics (searches for exotic particles and measurement of half-lives). In addition, accelerator mass spectrometry may become an important tool for the materials and biological sciences. 98 references, 4 figures, 2 tables.

  7. Direct and Convenient Mass Spectrometry Sampling with Ambient Flame Ionization

    PubMed Central

    Liu, Xiao-Pan; Wang, Hao-Yang; Zhang, Jun-Ting; Wu, Meng-Xi; Qi, Wan-Shu; Zhu, Hui; Guo, Yin-Long

    2015-01-01

    Recent innovations in ambient ionization technology for the direct analysis of various samples in their native environment facilitate the development and applications of mass spectrometry in natural science. Presented here is a novel, convenient and flame-based ambient ionization method for mass spectrometric analysis of organic compounds, termed as the ambient flame ionization (AFI) ion source. The key features of AFI ion source were no requirement of (high) voltages, laser beams and spray gases, but just using small size of n-butane flame (height approximately 1 cm, about 500 oC) to accomplish the rapid desorption and ionization for direct analysis of gaseous-, liquid- and solid-phase organic compounds, as well as real-world samples. This method has high sensitivity with a limit of detection of 1 picogram for propyphenazone, which allows consuming trace amount of samples. Compared to previous ionization methods, this ion source device is extremely simple, maintain-free, low-cost, user–friendly so that even an ordinary lighter (with n-butane as fuel) can achieve efficient ionization. A new orientation to mass spectrometry ion source exploitation might emerge from such a convenient, easy and inexpensive AFI ion source. PMID:26582511

  8. Direct and Convenient Mass Spectrometry Sampling with Ambient Flame Ionization.

    PubMed

    Liu, Xiao-Pan; Wang, Hao-Yang; Zhang, Jun-Ting; Wu, Meng-Xi; Qi, Wan-Shu; Zhu, Hui; Guo, Yin-Long

    2015-01-01

    Recent innovations in ambient ionization technology for the direct analysis of various samples in their native environment facilitate the development and applications of mass spectrometry in natural science. Presented here is a novel, convenient and flame-based ambient ionization method for mass spectrometric analysis of organic compounds, termed as the ambient flame ionization (AFI) ion source. The key features of AFI ion source were no requirement of (high) voltages, laser beams and spray gases, but just using small size of n-butane flame (height approximately 1 cm, about 500 (o)C) to accomplish the rapid desorption and ionization for direct analysis of gaseous-, liquid- and solid-phase organic compounds, as well as real-world samples. This method has high sensitivity with a limit of detection of 1 picogram for propyphenazone, which allows consuming trace amount of samples. Compared to previous ionization methods, this ion source device is extremely simple, maintain-free, low-cost, user-friendly so that even an ordinary lighter (with n-butane as fuel) can achieve efficient ionization. A new orientation to mass spectrometry ion source exploitation might emerge from such a convenient, easy and inexpensive AFI ion source. PMID:26582511

  9. Direct and Convenient Mass Spectrometry Sampling with Ambient Flame Ionization

    NASA Astrophysics Data System (ADS)

    Liu, Xiao-Pan; Wang, Hao-Yang; Zhang, Jun-Ting; Wu, Meng-Xi; Qi, Wan-Shu; Zhu, Hui; Guo, Yin-Long

    2015-11-01

    Recent innovations in ambient ionization technology for the direct analysis of various samples in their native environment facilitate the development and applications of mass spectrometry in natural science. Presented here is a novel, convenient and flame-based ambient ionization method for mass spectrometric analysis of organic compounds, termed as the ambient flame ionization (AFI) ion source. The key features of AFI ion source were no requirement of (high) voltages, laser beams and spray gases, but just using small size of n-butane flame (height approximately 1 cm, about 500 oC) to accomplish the rapid desorption and ionization for direct analysis of gaseous-, liquid- and solid-phase organic compounds, as well as real-world samples. This method has high sensitivity with a limit of detection of 1 picogram for propyphenazone, which allows consuming trace amount of samples. Compared to previous ionization methods, this ion source device is extremely simple, maintain-free, low-cost, user-friendly so that even an ordinary lighter (with n-butane as fuel) can achieve efficient ionization. A new orientation to mass spectrometry ion source exploitation might emerge from such a convenient, easy and inexpensive AFI ion source.

  10. Laser desorption mass spectrometry for point mutation detection

    SciTech Connect

    Taranenko, N.I.; Chung, C.N.; Zhu, Y.F.

    1996-12-31

    A point mutation can be associated with the pathogenesis of inherited or acquired diseases. Laser desorption mass spectrometry coupled with allele specific polymerase chain reaction (PCR) was first used for point mutation detection. G551D is one of several mutations of the cystic fibrosis transmembrane conductance regulator (CFTR) gene present in 1-3% of the mutant CFTR alleles in most European populations. In this work, two different approaches were pursued to detect G551D point mutation in the cystic fibrosis gene. The strategy is to amplify the desired region of DNA template by PCR using two primers that overlap one base at the site of the point mutation and which vary in size. If the two primers based on the normal sequence match the target DNA sequence, a normal PCR product will be produced. However, if the alternately sized primers that match the mutant sequence recognize the target DNA, an abnormal PCR product will be produced. Thus, the mass spectrometer can be used to identify patients that are homozygous normal, heterozygous for a mutation or homozygous abnormal at a mutation site. Another approach to identify similar mutations is the use of sequence specific restriction enzymes which respond to changes in the DNA sequence. Mass spectrometry is used to detect the length of the restriction fragments by digestion of a PCR generated target fragment. 21 refs., 10 figs., 2 tabs.

  11. Laser desorption mass spectrometry for point mutation detection

    SciTech Connect

    Taranenko, N.I.; Chung, C.N.; Zhu, Y.F.

    1996-10-01

    A point mutation can be associated with the pathogenesis of inherited or acquired diseases. Laser desorption mass spectrometry coupled with allele specific polymerase chain reaction (PCR) was first used for point mutation detection. G551D is one of several mutations of the cystic fibrosis transmembrane conductance regulator (CFTR) gene present in 1-3% of the mutant CFTR alleles in most European populations. In this work, two different approaches were pursued to detect G551D point mutation in the cystic fibrosis gene. The strategy is to amplify the desired region of DNA template by PCR using two primers that overlap one base at the site of the point mutation and which vary in size. If the two primers based on the normal sequence match the target DNA sequence, a normal PCR product will be produced. However, if the alternately sized primers that match the mutant sequence recognize the target DNA, an abnormal PCR product will be produced. Thus, the mass spectrometer can be used to identify patients that are homozygous normal, heterozygous for a mutation or homozygous abnormal at a mutation site. Another approach to identify similar mutations is the use of sequence specific restriction enzymes which respond to changes in the DNA sequence. Mass spectrometry is used to detect the length of the restriction fragments generated by digestion of a PCR generated target fragment. 21 refs., 10 figs., 2 tabs.

  12. Capillary zone electrophoresis-mass spectrometry of peptides and proteins

    SciTech Connect

    Loo, J.A.; Udseth, H.R.; Smith, R.D.

    1989-05-01

    Capillary zone electrophoresis (CZE) is attracting extensive attention as a fast, high resolution analytical and micro-preparative separations technique for systems of biological interest. In zone electrophoresis, a column is filled with a single electrolyte having a specific conductivity. The mixture of substances to be separated is applied as a narrow band to the head of a buffer filled column in a band whose width is much less than the length of the column and at a concentration too low to affect the buffer conductivity. An electric field is then applied across the length of the column and the individual substances migrate and separate according to their net electrophoretic velocities. Zone electrophoresis carried out in small diameter (<100 ..mu..m) fused silica capillaries is a relatively new approach to the high resolution separation of aqueous samples. Very small volume samples (picoliter range) with separation efficiencies on the order of 10/sup 6/ theoretical plates for amino acids have been achieved. The method can be further enhanced by the dynamic combination of detection sensitivity and selectivity offered by mass spectrometry (MS). The on-line marriage of mass spectrometry to CZE is accomplished by an atmospheric pressure electrospray ionization source interface. Our research efforts have demonstrated that proteins with MW's greater than 100 kDa can be analyzed using a conventional quadrupole mass spectrometer with an upper m/z limit of only 1700. 6 refs.

  13. Future Directions of Structural Mass Spectrometry using Hydroxyl Radical Footprinting

    SciTech Connect

    J Kiselar; M Chance

    2011-12-31

    Hydroxyl radical protein footprinting coupled to mass spectrometry has been developed over the last decade and has matured to a powerful method for analyzing protein structure and dynamics. It has been successfully applied in the analysis of protein structure, protein folding, protein dynamics, and protein-protein and protein-DNA interactions. Using synchrotron radiolysis, exposure of proteins to a 'white' X-ray beam for milliseconds provides sufficient oxidative modification to surface amino acid side chains, which can be easily detected and quantified by mass spectrometry. Thus, conformational changes in proteins or protein complexes can be examined using a time-resolved approach, which would be a valuable method for the study of macromolecular dynamics. In this review, we describe a new application of hydroxyl radical protein footprinting to probe the time evolution of the calcium-dependent conformational changes of gelsolin on the millisecond timescale. The data suggest a cooperative transition as multiple sites in different molecular subdomains have similar rates of conformational change. These findings demonstrate that time-resolved protein footprinting is suitable for studies of protein dynamics that occur over periods ranging from milliseconds to seconds. In this review, we also show how the structural resolution and sensitivity of the technology can be improved as well. The hydroxyl radical varies in its reactivity to different side chains by over two orders of magnitude, thus oxidation of amino acid side chains of lower reactivity are more rarely observed in such experiments. Here we demonstrate that the selected reaction monitoring (SRM)-based method can be utilized for quantification of oxidized species, improving the signal-to-noise ratio. This expansion of the set of oxidized residues of lower reactivity will improve the overall structural resolution of the technique. This approach is also suggested as a basis for developing hypothesis

  14. Characterization of HOCl using atmospheric pressure ionization mass spectrometry

    SciTech Connect

    Caldwell, T.E.; Foster, K.L.; Benter, T.; Langer, S.; Hemminger, J.C.; Finlayson-Pitts, B.J.

    1999-10-14

    HOCl is an important intermediate in stratospheric and tropospheric chemistry. Although it can be readily measured in laboratory systems at low pressures ({le}20 Torr) using conventional electron impact ionization mass spectrometry, there is a need for a measurement technique that can operate at higher pressures, up to 1 atm in air. One such technique seeing increasing use is atmospheric pressure ionization mass spectrometry (API-MS). The authors report here studies of the API-MS of {approximately}0.5--50 ppm HOCl at a total pressure of 1 atm and room temperature. Major peaks from the ion-adducts with Cl{sup {minus}} and OCI{sup {minus}} were observed. The Br{sup {minus}} adduct of HOCl can also be generated using bromoform in the discharge region of the ion source. At the lower range of HOCl concentrations studied in air, the O{sub 2}{sup {minus}} adduct and small parent peaks assigned to HOCl{sup {minus}} were observed. The species present as minor impurities in the HOCl source (Cl{sub 2}, Cl{sub 2}O and HCl) can be readily distinguished through identification of the parent ion for Cl{sub 2}, or as their adducts with Cl{sup {minus}} and Br{sup {minus}} for Cl{sub 2}O and HCI. The identification of HOCl was confirmed using electron impact ionization time-of-flight mass spectrometry (El-MS). HOCl was quantified using EI-MS to measure the Cl{sub 2} generated when the HOCl reacted heterogeneously on a water-ice/HCl surface and independently by photolysis of the HOCl to generate atomic chlorine, which was trapped using propene and measured as chloroacetone. The implications for the use of API-MS for measuring HOCl in laboratory systems and in ambient air are discussed.

  15. Using isotope dilution mass spectrometry to determine aqueous trichloroacetic acid

    SciTech Connect

    Norwood, D.L.; Christman, R.F.; Johnson, J.D.; Hass, J.R.

    1986-01-01

    The development, verification, and application of a method based on isotope-dilution gas chromatography-mass spectrometry to determine aqueous trichloroacetic acid (TCAA) at the micrograms per litre level are described. The simultaneous determination of aqueous chloroform is also demonstrated. Trichloroacetic acid is shown to be a significant by-product of the chlorination of raw waters in the laboratory and to constitute a large fraction of the total organic halide (TOX) formed. Analysis of finished-water samples indicated that TCAA, like trihalomethanes is ubiquitous. Positive correlations exist between the levels of TCAA in laboratory-chlorinated raw waters and in finished waters and measured TOX.

  16. Hydrogen exchange mass spectrometry: Are we out of the quicksand?

    PubMed Central

    Iacob, Roxana E.; Engen, John R.

    2012-01-01

    Although the use of hydrogen exchange (HX) mass spectrometry (MS) to study proteins and protein conformation is now over 20 years old, the perception lingers that it still has “issues”. Is this method, in fact, still in the quicksand with many remaining obstacles to overcome? We do not think so. This critical insight addresses the “issues” and explores several broad questions including: have the limitations of HX MS been surmounted and has HX MS achieved “indispensable” status in the pantheon of protein structural analysis tools. PMID:22476891

  17. Separation of steroid isomers by ion mobility mass spectrometry.

    PubMed

    Ahonen, Linda; Fasciotti, Maíra; Gennäs, Gustav Boije Af; Kotiaho, Tapio; Daroda, Romeu J; Eberlin, Marcos; Kostiainen, Risto

    2013-10-01

    Ion mobility mass spectrometry performed in a compact traveling wave cell (TWIM-MS) is shown to provide a reliable, fast and repeatable method to separate derivatized steroid isomers. Three steroid isomer pairs were analyzed in their native form and as their p-toluenesulfonyl isocyanate derivatives. The native steroids were separated from each other, but no separation could be attained for the isomers. The derivatized steroid isomers were, however, properly separated by TWIM-MS with peak-to-peak resolutions close to or as high as baseline resolution (Rp-p=0.77-1.08). PMID:23992881

  18. Application of accelerator mass spectrometry in aluminum metabolism studies

    NASA Astrophysics Data System (ADS)

    Meirav, O.; Sutton, R. A. L.; Fink, D.; Middleton, R.; Klein, J.; Walker, V. R.; Halabe, A.; Vetterli, D.; Johnson, R. R.

    1990-12-01

    The recent recognition that aluminum causes toxicity in uremie patients and may be associated with Alzheimer's disease has stimulated many studies of its biochemical effects. However, such studies were hampered by the lack of a suitable tracer. In a novel experiment, we have applied the new technique of accelerator mass spectrometry to investigate aluminum kinetics in rats, using as a marker the long-lived isotope 26Al. We present the first aluminum kinetic model for a biological system. The results clearly demonstrate the advantage this technique holds for isotope tracer studies in animals as well as in humans.

  19. Mass spectrometry cancer data classification using wavelets and genetic algorithm.

    PubMed

    Nguyen, Thanh; Nahavandi, Saeid; Creighton, Douglas; Khosravi, Abbas

    2015-12-21

    This paper introduces a hybrid feature extraction method applied to mass spectrometry (MS) data for cancer classification. Haar wavelets are employed to transform MS data into orthogonal wavelet coefficients. The most prominent discriminant wavelets are then selected by genetic algorithm (GA) to form feature sets. The combination of wavelets and GA yields highly distinct feature sets that serve as inputs to classification algorithms. Experimental results show the robustness and significant dominance of the wavelet-GA against competitive methods. The proposed method therefore can be applied to cancer classification models that are useful as real clinical decision support systems for medical practitioners. PMID:26611346

  20. Biomedical Mass Spectrometry in Today's and Tomorrow's Clinical Microbiology Laboratories

    PubMed Central

    Welker, Martin; Erhard, Marcel; Chatellier, Sonia

    2012-01-01

    Clinical microbiology is a conservative laboratory exercise where base technologies introduced in the 19th century remained essentially unaltered. High-tech mass spectrometry (MS) has changed that. Within a few years following its adaptation to microbiological diagnostics, MS has been introduced, embraced, and broadly accepted by clinical microbiology laboratories throughout the world as an innovative tool for definitive bacterial species identification. Herein, we review the current state of the art with respect to this exciting new technology and discuss potential future applications. PMID:22357505

  1. Biomedical mass spectrometry in today's and tomorrow's clinical microbiology laboratories.

    PubMed

    van Belkum, Alex; Welker, Martin; Erhard, Marcel; Chatellier, Sonia

    2012-05-01

    Clinical microbiology is a conservative laboratory exercise where base technologies introduced in the 19th century remained essentially unaltered. High-tech mass spectrometry (MS) has changed that. Within a few years following its adaptation to microbiological diagnostics, MS has been introduced, embraced, and broadly accepted by clinical microbiology laboratories throughout the world as an innovative tool for definitive bacterial species identification. Herein, we review the current state of the art with respect to this exciting new technology and discuss potential future applications. PMID:22357505

  2. Fission Yield Measurements by Inductively Coupled Plasma Mass-Spectrometry

    SciTech Connect

    Irina Glagolenko; Bruce Hilton; Jeffrey Giglio; Daniel Cummings; Karl Grimm; Richard McKnight

    2009-11-01

    Correct prediction of the fission products inventory in irradiated nuclear fuels is essential for accurate estimation of fuel burnup, establishing proper requirements for spent fuel transportation and storage, materials accountability and nuclear forensics. Such prediction is impossible without accurate knowledge of neutron induced fission yields. Unfortunately, the accuracy of the fission yields reported in the ENDF/B-VII.0 library is not uniform across all of the data and much of the improvement is desired for certain isotopes and fission products. We discuss our measurements of cumulative fission yields in nuclear fuels irradiated in thermal and fast reactor spectra using Inductively Coupled Plasma Mass Spectrometry.

  3. Small sample Accelerator Mass Spectrometry for biomedical applications

    NASA Astrophysics Data System (ADS)

    Salehpour, M.; Håkansson, K.; Possnert, G.

    2015-10-01

    The Accelerator Mass Spectrometry activities at Uppsala University include a group dedicated to the biomedical applications, involving natural level samples, as well as 14C-labeled substances requiring separate handling and preparation. For most applications sufficient sample amounts are available but many applications are limited to samples sizes in the μg-range. We have developed a preparation procedure for small samples biomedical applications, where a few μg C can be analyzed, albeit with compromised precision. The latest results for the small sample AMS method are shown and some of the biomedical activities at our laboratory are presented.

  4. Vaporization Studies of Olivine via Knudsen Effusion Mass Spectrometry

    NASA Technical Reports Server (NTRS)

    Costa, G. C. C.; Jacobson, N. S.

    2014-01-01

    Olivine is the major mineral in the Earth's upper mantle occurring predominantly in igneous rocks and has been identified in meteorites, asteroids, the Moon and Mars. Among many other important applications in planetary and materials sciences, the thermodynamic properties of vapor species from olivine are crucial as input parameters in computational modelling of the atmospheres of hot, rocky exoplanets (lava planets). There are several weight loss studies of olivine vaporization in the literature and one Knudsen Effusion Mass Spectrometry (KEMS) study. In this study, we examine a forsterite-rich olivine (93% forsterite and 7% fayalite, Fo93Fa7) with KEMS to further understand its vaporization and thermodynamic properties.

  5. Laser desorption postionization mass spectrometry imaging of biological targets.

    PubMed

    Akhmetov, Artem; Bhardwaj, Chhavi; Hanley, Luke

    2015-01-01

    Laser desorption photoionization mass spectrometry (LDPI-MS) utilizes two separate light sources for desorption and photoionization of species from a solid surface. This technique has been applied to study a wide variety of molecular analytes in biological systems, but is not yet available in commercial instruments. For this reason, a generalized protocol is presented here for the use of LDPI-MS imaging to detect small molecules within intact biological samples. Examples are provided here for LDPI-MS imaging of an antibiotic within a tooth root canal and a metabolite within a coculture bacterial biofilm. PMID:25361678

  6. Fluorescence preselection of bioaerosol for single-particle mass spectrometry.

    PubMed

    Stowers, M A; van Wuijckhuijse, A L; Marijnissen, J C M; Kientz, Ch E; Ciach, T

    2006-11-20

    We have designed, constructed, and tested a system that pre-selects the biological fraction of airborne particles from the overall aerosol. The preselection is based on fluorescence emission excited by a continuous 266 nm laser beam. This beam is one of two cw beams used to measure the aerodynamic particle size of sampled particles. The intention in our system is that single particles, based on size and fluorescence emission, can be selected and further examined for chemical composition by mass spectrometry. PMID:17086265

  7. Study of projectile fragmentation reaction with isochronous mass spectrometry

    NASA Astrophysics Data System (ADS)

    Tu, X. L.; Mei, B.; Zhang, Y. H.; Xu, H. S.; Litvinov, Yu A.; Huang, W. J.; Podolyak, Z.; Kelic-Heil, A.; Zhang, W.; Litvinov, S. A.; Blaum, K.; Zhou, X. H.; Shuai, P.; Wang, M.; Gao, B. S.; Chen, X. C.; Yuan, Y. J.; Xia, J. W.; Yang, J. C.; Hu, Z. G.; Ma, X. W.; Sun, B. H.; Yan, X. L.; Mao, R. S.; Sun, Z. Y.; Xiao, G. Q.; Xu, X.; Walker, P. M.; Yamaguchi, T.; Bosch, F.; Winckler, N.; Chen, R. J.; Xing, Y. M.; Fu, C. Y.; Liu, D. W.; Zeng, Q.; Ge, Z.; Sun, Y.; Zhao, H. W.; Zhao, T. C.

    2015-11-01

    Relative yields of fragments following the 78Kr projectile fragmentation in a beryllium target were measured in a storage ring by using isochronous mass spectrometry (IMS). Odd-even staggering of the relative fragment yields is observed and can be explained by the odd-even staggering of the particle-emission threshold energies. IMS is a complementary technique to γ-ray spectroscopy for measuring isomeric ratios, in particular for nuclides with long lifetimes. It was found that the isomeric yield ratios in 53Fe are almost constant for different longitudinal momenta.

  8. Semitransparent nanostructured films for imaging mass spectrometry and optical microscopy.

    PubMed

    Forsythe, Jay G; Broussard, Joshua A; Lawrie, Jenifer L; Kliman, Michal; Jiao, Yang; Weiss, Sharon M; Webb, Donna J; McLean, John A

    2012-12-18

    Semitransparent porous silicon substrates have been developed for pairing nanostructure-initiator mass spectrometry (NIMS) imaging with traditional optical-based microscopy techniques. Substrates were optimized to generate the largest NIMS signal while maintaining sufficient transparency to allow visible light to pass through for optical microscopy. Using these substrates, both phase-contrast and NIMS images of phospholipids from a scratch-wounded cell monolayer were obtained. NIMS images were generated using a spatial resolution of 14 μm. Coupled with further improvements in spatial resolution, this approach may allow for the localization of intact biological molecules within cells without the need for labeling. PMID:23146026

  9. Pore-scale supercritical CO2 dissolution and mass transfer under imbibition conditions

    NASA Astrophysics Data System (ADS)

    Chang, Chun; Zhou, Quanlin; Kneafsey, Timothy J.; Oostrom, Mart; Wietsma, Thomas W.; Yu, Qingchun

    2016-06-01

    In modeling of geological carbon storage, dissolution of supercritical CO2 (scCO2) is often assumed to be instantaneous with equilibrium phase partitioning. In contrast, recent core-scale imbibition experiments have shown a prolonged depletion of residual scCO2 by dissolution, implying a non-equilibrium mechanism. In this study, eight pore-scale scCO2 dissolution experiments in a 2D heterogeneous, sandstone-analog micromodel were conducted at supercritical conditions (9 MPa and 40 °C). The micromodel was first saturated with deionized (DI) water and drained by injecting scCO2 to establish a stable scCO2 saturation. DI water was then injected at constant flow rates after scCO2 drainage was completed. High resolution time-lapse images of scCO2 and water distributions were obtained during imbibition and dissolution, aided by a scCO2-soluble fluorescent dye introduced with scCO2 during drainage. These images were used to estimate scCO2 saturations and scCO2 depletion rates. Experimental results show that (1) a time-independent, varying number of water-flow channels are created during imbibition and later dominant dissolution by the random nature of water flow at the micromodel inlet, and (2) a time-dependent number of water-flow channels are created by coupled imbibition and dissolution following completion of dominant imbibition. The number of water-flow paths, constant or transient in nature, greatly affects the overall depletion rate of scCO2 by dissolution. The average mass fraction of dissolved CO2 (dsCO2) in water effluent varies from 0.38% to 2.72% of CO2 solubility, indicating non-equilibrium scCO2 dissolution in the millimeter-scale pore network. In general, the transient depletion rate decreases as trapped, discontinuous scCO2 bubbles and clusters within water-flow paths dissolve, then remains low with dissolution of large bypassed scCO2 clusters at their interfaces with longitudinal water flow, and finally increases with coupled transverse water flow and

  10. Linked Gas Chromatography/Fourier Transform Infrared Spectrometry/Fourier Transform Mass Spectrometry For Mixture Analysis

    NASA Astrophysics Data System (ADS)

    Laude, David A., Jr.; Johlman, Carolyn; Wilkins, Charles L.

    1985-12-01

    During the past few years it has been demonstrated that linkage of multiple spectrometry systems with gas chromatography (GC) offers significant advantages for structural analysis of mixture components as they are sepa-rated. In the work to be described, a Fourier transform mass spectrometer (FTMS) has been linked in parallel with a Fourier transform infrared (FTIR) spectrometer for concurrent analysis of GC eluants from a fused silica capillary column. This system provides FTIR, electron impact, and chemical ionization mass spectral analysis of each mixture component as it emerges from the GC. Furthermore, mass measurement accuracy in the low ppm range in the absence of calibrant is made possible by the FTMS. Effective use of the com-plementary information obtained is shown to produce more reliable analytical performance than for any individual measurement.

  11. Characterization of polymer decomposition products by laser desorption mass spectrometry

    NASA Technical Reports Server (NTRS)

    Pallix, Joan B.; Lincoln, Kenneth A.; Miglionico, Charles J.; Roybal, Robert E.; Stein, Charles; Shively, Jon H.

    1993-01-01

    Laser desorption mass spectrometry has been used to characterize the ash-like substances formed on the surfaces of polymer matrix composites (PMC's) during exposure on LDEF. In an effort to minimize fragmentation, material was removed from the sample surfaces by laser desorption and desorbed neutrals were ionized by electron impact. Ions were detected in a time-of-flight mass analyzer which allows the entire mass spectrum to be collected for each laser shot. The method is ideal for these studies because only a small amount of ash is available for analysis. Three sets of samples were studied including C/polysulfone, C/polyimide and C/phenolic. Each set contains leading and trailing edge LDEF samples and their respective controls. In each case, the mass spectrum of the ash shows a number of high mass peaks which can be assigned to fragments of the associated polymer. These high mass peaks are not observed in the spectra of the control samples. In general, the results indicate that the ash is formed from decomposition of the polymer matrix.

  12. Incorporating Biological Mass Spectrometry into Undergraduate Teaching Labs, Part 1: Identifying Proteins Based on Molecular Mass

    ERIC Educational Resources Information Center

    Arnquist, Isaac J.; Beussman, Douglas J.

    2007-01-01

    Biological mass spectrometry is an important analytical technique in drug discovery, proteomics, and research at the biology-chemistry interface. Currently, few hands-on opportunities exist for undergraduate students to learn about this technique. With the 2002 Nobel Prize being awarded, in part, for the development of biological mass…

  13. Enantioseparation and determination of isofenphos-methyl enantiomers in wheat, corn, peanut and soil with Supercritical fluid chromatography/tandem mass spectrometric method.

    PubMed

    Chen, Xixi; Dong, Fengshou; Xu, Jun; Liu, Xingang; Chen, Zenglong; Liu, Na; Zheng, Yongquan

    2016-03-15

    Supercritical fluid chromatography/tandem mass spectrometry (SFC-MS/MS) is an effective tool in separation science which uses the nontoxic CO2 fluid for better control of analyte retention. Also the technology of a postcolumn additive to complement MS/MS ensure the high-selectivity determination. In this paper, a green and sensitive analytical method was developed for the enantioselective separation and determination of isofenphos-methyl enantiomers in foodstuff and soil by SFC-MS/MS. The enantioseparation was performed within 3.50min using Chiralpak IA-3 column with CO2/isopropanol (90:10, v/v) as the mobile phase at 2.2mL/min flow rate. The postcolumn compensation technology provided with 0.1% formic acid/methanol greatly improved the ionization efficiency of mass spectrometry. Column temperature, auto back pressure regulator pressure, and flow rate of compensation solvent were optimized to 30°C, 2200psi, and 0.1mL/min, respectively. The QuEChERs method was adopted in this study, which mean recoveries of isofenphos-methyl enantiomers ranged from 75.7% to 111.4%, with relative standard deviations less than 11.3% at three concentration levels in all matrices. The limits of detection for both enantiomers varied from 0.02μg/kg to 0.15μg/kg, while the limit of quantification did not exceed 0.50μg/kg. The proposed method was then successfully applied to analyze authentic samples, confirming that it was a versatile strategy for the analysis of isofenphos-methyl enantiomers in food and environmental matrices. PMID:26894851

  14. Single Cell Proteomics with Ultra-High Sensitivity Mass Spectrometry

    SciTech Connect

    Frank, M

    2005-02-16

    This project was a joint LDRD project between PAT, CMS and NAI with the objective to develop an instrument that analyzes the biochemical composition of single cells in real-time using bioaerosol mass spectrometry (BAMS) combined with advanced laser desorption and ionization techniques. Applications include both biological defense, fundamental cell biology and biomedical research. BAMS analyzes the biochemical composition of single, micrometer-sized particles (such as bacterial cells or spores) that can be directly sampled from air or a suspension. BAMS is based on an earlier development of aerosol time of flight mass spectrometry (ATOFMS) by members of our collaboration [1,2]. Briefly, in ATOFMS and BAMS aerosol particles are sucked directly from the atmosphere into vacuum through a series of small orifices. As the particles approach the ion source region of the mass spectrometer, they cross and scatter light from two CW laser beams separated by a known distance. The timing of the two bursts of scattered light created by each ''tracked'' particle reveals the speed, location and size of the particle. This information then enables the firing of a high-intensity laser such that the resulting laser pulse desorbs and ionizes molecules from the tracked particle just as it reaches the center of the ion source region. The full spectrum of ions is then measured using a time-of-flight mass spectrometer. The ability to rapidly analyze individual particles is clearly applicable to the rapid detection of aerosolized biological warfare agents so long as agent particles can be made to produce mass spectra that are distinct from the spectra of harmless background particles. The pattern of ions formed is determined by the properties of the laser pulse, the particle, and, in aerosol matrix-assisted laser desorption/ionization (MALDI), also the MALDI matrix used. As a result, it is critical that the properties of the laser pulses used for desorption and ionization be carefully chosen

  15. IDENTIFICATION OF DYES BY THERMOSPRAY IONIZATION AND MASS SPECTROMETRY/MASS SPECTROMETRY

    EPA Science Inventory

    The identification of ionic dyestuffs by thermospray ionization and MS/MS using a triple quadrupole mass spectrometer is reported. Basic Red 14 is shown to contain three major constituents, with ions at m/z 344, 291 and 346, respectively, identified by collision activated dissoci...

  16. Nitrogen incorporation in Titan's tholins inferred by high resolution orbitrap mass spectrometry and gas chromatography-mass spectrometry

    NASA Astrophysics Data System (ADS)

    Gautier, Thomas; Carrasco, Nathalie; Schmitz-Afonso, Isabelle; Touboul, David; Szopa, Cyril; Buch, Arnaud; Pernot, Pascal

    2014-10-01

    Influx of solar photons and heavy charged particles from Saturn's magnetosphere on Titan's atmosphere - mainly comprised of methane and nitrogen - induce an intense organic photochemistry which leads to the formation of a large amount of aerosols in suspension in the atmosphere. In order to infer the role of nitrogen in aerosol formation processes we produced laboratory analogs of Titan's aerosols. In this work, we compare the composition of different analogs by using high resolution mass spectrometry and propose an additional study using gas-chromatography coupled to mass-spectrometry for a new kind of analog produced by polymerization of cryogenically trapped gaseous neutral species. The comparison of these materials emphasizes the importance of ion chemistry processes for the inclusion of nitrogen in molecules constituting Titan's tholins. A statistical approach is also used for the treatment of high resolution mass spectra of these highly complex organic materials. This method allows distinguishing molecular families that can be reconstructed by an ideal copolymer. We investigate several copolymer reconstructions, and we suggest that an HCN (or CH3CN)/C2H4 based copolymer agrees well with the polymeric structure of tholins produced with 5% of methane in nitrogen.

  17. Testing and Validation of Computational Methods for Mass Spectrometry.

    PubMed

    Gatto, Laurent; Hansen, Kasper D; Hoopmann, Michael R; Hermjakob, Henning; Kohlbacher, Oliver; Beyer, Andreas

    2016-03-01

    High-throughput methods based on mass spectrometry (proteomics, metabolomics, lipidomics, etc.) produce a wealth of data that cannot be analyzed without computational methods. The impact of the choice of method on the overall result of a biological study is often underappreciated, but different methods can result in very different biological findings. It is thus essential to evaluate and compare the correctness and relative performance of computational methods. The volume of the data as well as the complexity of the algorithms render unbiased comparisons challenging. This paper discusses some problems and challenges in testing and validation of computational methods. We discuss the different types of data (simulated and experimental validation data) as well as different metrics to compare methods. We also introduce a new public repository for mass spectrometric reference data sets ( http://compms.org/RefData ) that contains a collection of publicly available data sets for performance evaluation for a wide range of different methods. PMID:26549429

  18. Mass Spectrometry of Protein Complexes: From Origins to Applications

    NASA Astrophysics Data System (ADS)

    Mehmood, Shahid; Allison, Timothy M.; Robinson, Carol V.

    2015-04-01

    Now routine is the ability to investigate soluble and membrane protein complexes in the gas phase of a mass spectrometer while preserving folded structure and ligand-binding properties. Several recent transformative developments have occurred to arrive at this point. These include advances in mass spectrometry instrumentation, particularly with respect to resolution; the ability to study intact membrane protein complexes released from detergent micelles; and the use of protein unfolding in the gas phase to obtain stability parameters. Together, these discoveries are providing unprecedented information on the compositional heterogeneity of biomacromolecules, the unfolding trajectories of multidomain proteins, and the stability imparted by ligand binding to both soluble and membrane-embedded protein complexes. We review these recent breakthroughs, highlighting the challenges that had to be overcome and the physicochemical insight that can now be gained from studying proteins and their assemblies in the gas phase.

  19. Rapid authentication of Gastrodiae rhizoma by direct ionization mass spectrometry.

    PubMed

    Wong, Ho-Yi; Hu, Bin; So, Pui-Kin; Chan, Chi-On; Mok, Daniel Kam-Wah; Xin, Gui-Zhong; Li, Ping; Yao, Zhong-Ping

    2016-09-28

    In this study, direct ionization mass spectrometry (DI-MS) for rapid authentication of Gastrodiae rhizoma (known as Tianma in Chinese), a popular herbal medicine, has been developed. This method is rapid, simple and allows direct generation of characteristic mass spectra from the raw herbal medicines with the application of some solvents and a high voltage. The acquired DI-MS spectra showed that gastrodin, parishin B/parishin C and parishin, the major active components of Gastrodiae rhizoma, could be found only in genuine Gastrodiae rhizoma samples, but not in counterfeit samples, thus allowing rapid authentication of Gastrodiae rhizoma. Moreover, wild and cultivated Gastrodiae rhizoma could be classified and Gastrodiae rhizoma from different geographical locations could be differentiated based on their different intensity ratios of characteristic ions or principal component analysis (PCA). This method is simple, rapid, reproducible, and can be extended to analyze other herbal medicines. PMID:27619090

  20. Mass spectrometry. [in organic ion and biorganic chemistry and medicine

    NASA Technical Reports Server (NTRS)

    Burlingame, A. L.; Cox, R. E.; Derrick, P. J.

    1974-01-01

    Review of the present status of mass spectrometry in the light of pertinent recent publications spanning the period from December 1971 to January 1974. Following an initial survey of techniques, instruments, and computer applications, a sharp distinction is made between the chemistry of organic (radical-)ions and analytical applications in biorganic chemistry and medicine. The emphasis is on the chemistry of organic (radical-)ions at the expense of inorganic, organometallic, and surface ion chemistry. Biochemistry and medicine are chosen because of their contemporary importance and because of the stupendous contributions of mass spectroscopy to these fields in the past two years. In the review of gas-phase organic ion chemistry, special attention is given to studies making significant contributions to the understanding of ion chemistry.

  1. Isotope ratio mass spectrometry - history and terminology in brief.

    PubMed

    Flenker, Ulrich

    2012-12-01

    The history of isotope ratio mass spectrometry (IRMS) is briefly described. It is shown that the fundamental design of isotope ratio mass spectrometers has not changed since the 1940s. The basic findings concerning the natural variation of isotope abundances even date back to the 1930s. Recent improvements in the methodology mainly concern online coupling and analytical peripherals. The nature of isotopic scales necessitates a specific terminology which is unfamiliar to many analysts. However, corresponding guidelines exist that should be adopted by the anti-doping community. Currently, steroids represent the only group of compounds routinely analyzed by IRMS in doping-control. Suggestions are made in respect to a harmonized terminology concerning the nature and origins of steroids. PMID:22972693

  2. [Application of bio-mass spectrometry in cellular signal transduction].

    PubMed

    Zhang, Xue-Min; Wei, Kai-Hua; Yang, Song-Cheng

    2002-09-01

    The quickly developing techniques of biological mass spectrometry (bio-MS) in recent years realized the high throughput identification of proteins by determining the accurate mass values of trypsin digested peptides and the randomly selected peptide sequence tags, and have been successfully used in the studies of protein interactions and post-translational modification such as the phosphorylation. Compared to the conventional approaches, the above techniques can identify all the phosphorylated proteins (including their phosphorylated amino acid sites) involved in a multi-signal pathway in a single experiment, and they have been developed into a hot-spot of proteomics. The three strategies for the application of bio-MS in the above fields are briefly reviewed. PMID:12198553

  3. Perspectives on the future of analytical mass spectrometry

    SciTech Connect

    Basic, C.; Freeman, J.A.; Yost, R.A. )

    1990-11-01

    Unlike the secrecy of the early scientists of Oak Ridge, the free exchange of ideas between scientists at the 43rd Annual Summer Symposium on Analytical Chemistry led to the open discussion of new areas of instrumental development, new interfacing techniques, and increasingly challenging analytical problems. Chief among these challenges is the search for improved methods of analysis of high molecular weight species as questions of biochemical concern enter the realm of analytical MS (mass spectrometry). Furthermore, increasing attention is being focused on the use of chemical reactions in both the gas and solution phases to enhance the analytical capabilities of MS. By highlighting the interests of young mass spectrometrists, the symposium organizers succeeded not only in presenting the future areas of research in analytical MS but in introducing the people who will be pursuing these directives.

  4. Conditioning of ion sources for mass spectrometry of plasmas

    SciTech Connect

    Dylla, H.F.; Blanchard, W.R.

    1983-02-01

    Mass spectrometry is a useful diagnostic technique for monitoring plasma species and plasma-surface interactions. In order to maximize the sensitivity of measurements of hydrogen-fueled fusion plasmas or hydrogen-based discharge cleaning and etching plasmas, the ion sources of mass spectrometers are operated at or near the high pressure limit of 10/sup -4/ Torr (10/sup -2/ Pa). Such high ambient pressures of hydrogen give rise to high background levels of residual gases such as H/sub 2/O, CO, and CH/sub 4/, due to surface reactions on the ion source electrodes. For a commonly used ion source configuration, the residual gas production is a linear function of the ambient H/sub 2/ pressure. Hydrogen conditioning can reduce the absolute residual gas levels. Steady-state residual gas production is observed in a conditioned ion source, which is related to a balance of diffusion and sorption on the electrode surfaces.

  5. Characterization of glycosphingolipids by direct inlet chemical ionization mass spectrometry.

    PubMed

    Ariga, T; Murata, T; Oshima, M; Maezawa, M; Miyatake, T

    1980-09-01

    Permethylated derivatives of cerebrosides and ceramide di-, tri-, tetra-, and penta-hexosides were analyzed by the direct inlet ammonia chemical ionization (CI) mass spectrometry. In the CI mass spectra, the fragment ions produced by the loss of methanol from the protonated molecular ion were observed in all of the glycosphingolipids. Other fragment ions due to the cleavage of glycosidic moiety were major ones under the CI conditions. These ions provide information on the molecular species of glycosphingolipids and the sugar sequence of their oligosaccharides. Glycosphingolipids with hydroxy fatty acids could also be differentiated from those with nonhydroxy fatty acids by comparing the intensities of characteristic fragment ions. The CI method should be particularly useful in structural studies of glycosphingolipids from natural sources. PMID:7441059

  6. Deblurring molecular images using desorption electrospray ionization mass spectrometry

    PubMed Central

    Parry, R. Mitchell; Galhena, Asiri S.; Fernandez, Facundo M.; Wang, May D.

    2016-01-01

    Traditional imaging techniques for studying the spatial distribution of biological molecules such as proteins, metabolites, and lipids, require the a priori selection of a handful of target molecules. Imaging mass spectrometry provides a means to analyze thousands of molecules at a time within a tissue sample, adding spatial detail to proteomic, metabolomic, and lipidomic studies. Compared to traditional microscopic images, mass spectrometric images have reduced spatial resolution and require a destructive acquisition process. In order to increase spatial detail, we propose a constrained acquisition path and signal degradation model enabling the use of a general image deblurring algorithm. Our analysis shows the potential of this approach and supports prior observations that the effect of the sprayer focuses on a central region much smaller than the extent of the spray. PMID:19963935

  7. Probing protein stabilization by glycerol using electrospray mass spectrometry.

    PubMed

    Grandori, R; Matecko, I; Mayr, P; Müller, N

    2001-08-01

    This study shows that electrospray ionization mass spectrometry (ESI-MS), combined with a heated turbo ion-spray interface, allows monitoring protein stabilization by glycerol in solution. Measurements obtained with the two proteins lysozyme and cytochrome c are presented. The observed mass-to-charge (m/z) distributions reveal the stabilizing effect of the additive on the protein conformations against temperature and acid-induced unfolding, as well as against denaturation by acetonitrile. The data obtained with lysozyme allow detection of minor conformational changes upon glycerol addition to the native protein, and suggest that the protein structure in the presence of the additive is slightly compressed compared with its state in water. This result corroborates previous evidence obtained by nuclear magnetic resonance. It is also shown that analysis of the m/z distributions obtained by ESI-MS can lead to detection of partially folded and partially populated states in protein samples. PMID:11523091

  8. Field gas chromatography-mass spectrometry for fast analysis.

    PubMed

    Makas, Alexei L; Troshkov, Mikhail L

    2004-02-01

    The objective of this presentation is to demonstrate the original device and procedure for fast gas chromatography-mass spectrometry (GC-MS) analysis of gaseous and liquid samples and to discuss its features and capabilities. The concept was developed in order to expand the range of compounds suitable for GC separation and to reduce the time of analysis. Field GC-MS, consisting of original "concentrator-thermodesorber" (CTD) unit, multiple module GC system and compact magnetic mass spectrometer with powerful two-stage vacuum system and multicollector ion detector, is represented. The whole weight of the device is 90 kg. Power consumption is 250 W. The device and analytical procedures allow high speed screening of toxic substances in air and extracts within 100 s per sample. The examples of applications are described, including fast screening of tributyl phosphate (TBP) in air at low ppt level at the rate 1 sample/min. PMID:14698236

  9. Accessing natural product biosynthetic processes by mass spectrometry.

    PubMed

    Bumpus, Stefanie B; Kelleher, Neil L

    2008-10-01

    Two important classes of natural products are made by nonribosomal peptide synthetases (NRPSs) and polyketide synthases (PKSs). With most biosynthetic intermediates covalently tethered during biogenesis, protein mass spectrometry (MS) has proven invaluable for their interrogation. New mass spectrometric assay formats (such as selective cofactor ejection and proteomics style LC-MS) are showcased here in the context of functional insights into new breeds of NRPS/PKS enzymes, including the first characterization of an 'iterative' PKS, the biosynthesis of the enediyne antitumor antibiotics, the study of a new strategy for PKS initiation via a GNAT-like mechanism, and the analysis of branching strategies in the so-called 'AT-less' NRPS/PKS hybrid systems. The future of MS analysis of NRPS and PKS biosynthetic pathways lies in adoption and development of methods that continue bridging enzymology with proteomics as both fields continue their post-genomic acceleration. PMID:18706516

  10. A quantum sensor for high-performance mass spectrometry

    NASA Astrophysics Data System (ADS)

    Rodríguez, D.

    2012-06-01

    A novel device, called quantum sensor, has been conceived to measure the mass of a single ion with ultimate accuracy and unprecedented sensitivity while the ion is stored and cooled in a trap. The quantum sensor consists of a single calcium ion as sensor, which is laser cooled to mK temperatures and stored in a second trap connected to the trap for the ion under study by a common endcap. The cyclotron motion of the ion under investigation is transformed into axial motion along the magnetic field lines and coupled to the sensor ion by the image current induced in the common endcap. The axial motion of the sensor ion in turn is monitored spatially resolved by its fluorescence light. In this way the detection of phonons can be upgraded to a detection of photons. This device will allow one to overcome recent limitations in high-precision mass spectrometry.

  11. Profiling Signaling Peptides in Single Mammalian Cells Using Mass Spectrometry

    PubMed Central

    Rubakhin, Stanislav S.; Churchill, James D.; Greenough, William T.; Sweedler, Jonathan V.

    2008-01-01

    The peptide content of individual mammalian cells is profiled using matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectrometry. Both enzymatic and non-enzymatic procedures, including a glycerol cell stabilization method, are reported for the isolation of individual mammalian cells in a manner compatible with MALDI MS measurements. Guided microdeposition of MALDI matrix allows samples to be created with suitable analyte-to-matrix ratios. More than fifteen peptides are observed in individual rat intermediate pituitary cells. The combination of accurate mass data, expected cleavages by proteolytic enzymes, and post-source decay sequencing allows identification of fourteen of these peptides as pro-opiomelanocortin prohormone-derived molecules. These protocols permit the classification of individual mammalian cells by peptide profile, the elucidation of cell-specific prohormone processing, and the discovery of new signaling peptides on a cell-to-cell basis in a wide variety of mammalian cell types. PMID:17037931

  12. Sequencing of Oligourea Foldamers by Tandem Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Bathany, Katell; Owens, Neil W.; Guichard, Gilles; Schmitter, Jean-Marie

    2013-03-01

    This study is focused on sequence analysis of peptidomimetic helical oligoureas by means of tandem mass spectrometry, to build a basis for de novo sequencing for future high-throughput combinatorial library screening of oligourea foldamers. After the evaluation of MS/MS spectra obtained for model compounds with either MALDI or ESI sources, we found that the MALDI-TOF-TOF instrument gave more satisfactory results. MS/MS spectra of oligoureas generated by decay of singly charged precursor ions show major ion series corresponding to fragmentation across both CO-NH and N'H-CO urea bonds. Oligourea backbones fragment to produce a pattern of a, x, b, and y type fragment ions. De novo decoding of spectral information is facilitated by the occurrence of low mass reporter ions, representative of constitutive monomers, in an analogous manner to the use of immonium ions for peptide sequencing.

  13. Identification of Secreted Candida Proteins Using Mass Spectrometry.

    PubMed

    Gómez-Molero, Emilia; Dekker, Henk L; de Boer, Albert D; de Groot, Piet W J

    2016-01-01

    Analysis of fungal secretomes using mass spectrometry is a useful technique in cell biology. Knowledge of the secretome of a human fungal pathogen may yield important information of host-pathogen interactions and may be useful for identifying vaccines candidates or diagnostic markers for antifungal strategies. In this chapter, with a main focus on sample preparation aspects, we describe the methodology that we apply for gel-independent batch identification and quantification of proteins that are secreted during growth in liquid cultures. Using these techniques with Candida and other yeast species, the majority of the identified proteins are classical secretory proteins and cell wall proteins containing N-terminal signal peptides for secretion, although dependent on sample preparation quality and the mass spectrometric analysis also usually, a number of nonsecretory proteins are identified. PMID:26519067

  14. Mass Spectrometry for Planetary Probes: Past, Present and Future

    NASA Technical Reports Server (NTRS)

    Niemann, Hasso B.; Harpold, Dan N.; Jamieson, Brian G.; Mahaffy, Paul R.

    2005-01-01

    Atmospheric entry probes present a unique opportunity for performing quantitative analysis of extra-terrestrial atmospheres in cases where remote sensing alone may not be sufficient and measurements with balloons or aircraft is not practical. An entry probe can provide a complete vertical profile of atmospheric parameters including chemical composition, which cannot be obtained with most other techniques. There are, however, unique challenges associated with building instruments for an entry probe, as compared to orbiters, landers, or rovers. Conditions during atmospheric entry are extreme, there are inherent time constraints due to the short duration of the experiment, and the instrument experiences rapid environmental changes in temperature and pressure as it descends. In addition, there are resource limitations, i.e. mass, power, size and bandwidth. Finally, the demands on the instrument design are determined in large part by conditions (pressure, temperature, composition) unique to the particular body under study, and as a result there is no one-size-fits-all instrument for an atmospheric probe. Many of these requirements can be more easily met by miniaturizing the probe instrument. Our experience building mass spectrometers for atmospheric entry probes leads us to believe that the time is right for a fundamental change in the way spaceflight mass spectrometers are built. The emergence over the past twenty years of Micro-electro- mechanical Systems (MEMS), utilizing lithographic semiconductor fabrication techniques to produce instrument systems in miniature, holds great promise for application to spaceflight mass spectrometry. A highly miniaturized, high performance and low-power mass spectrometer would be an enormous benefit to future entry probe missions, allowing, for example, parallel measurements (e.g., multiple simultaneous gas chromatographic analyses and direct atmospheric leaks.) Such an instrument would also enable mass spectrometry on board small

  15. Charge detection mass spectrometry: Instrumentation & applications to viruses

    NASA Astrophysics Data System (ADS)

    Pierson, Elizabeth E.

    For over three decades, electrospray ionization (ESI) has been used to ionize non-covalent complexes and subsequently transfer the intact ion into the gas phase for mass spectrometry (MS) analysis. ESI generates a distribution of multiple charged ions, resulting in an m/z spectrum comprised of a series of peaks, known as a charge state envelope. To obtain mass information, the number of charges for each peak must be deduced. For smaller biological analytes like peptides, the charge states are sufficiently resolved and this process is straightforward. For macromolecular complexes exceeding ~100 kDa, this process is complicated by the broadening and shifting of charge states due to incomplete desolvation, salt adduction, and inherent mass heterogeneity. As the analyte mass approaches the MDa regime, the m/z spectrum is often comprised of a broad distribution of unresolved charge states. In such cases, mass determination is precluded. Charge detection mass spectrometry (CDMS) is an emerging MS technique for determining the masses of heterogeneous, macromolecular complexes. In CDMS, the m/z and z of single ions are measured concurrently so that mass is easily calculated. With this approach, deconvolution of an m/z spectrum is unnecessary. This measurement is carried out by passing macroions through a conductive cylinder. The induced image charge on the cylindrical detector provides information about m/z and z: the m/z is related to its time-of-flight through the detector, and the z is related to the intensity of the image charge. We have applied CDMS to study the self-assembly of virus capsids. Late-stage intermediates in the assembly of hepatitis B virus, a devastating human pathogen, have been identified. This is the first time that such intermediates have been detected and represent a significant advancement towards understanding virus capsid assembly. CDMS has also been used to identify oversized, non-icosahedral polymorphs in the assembly of woodchuck hepatitis

  16. Mass Spectrometry of Atmospheric Pressure Surface Wave Discharges

    NASA Astrophysics Data System (ADS)

    Ridenti, M. A.; Souza-Corrêa, J. A.; Amorim, J.

    2016-05-01

    By applying mass spectrometry techniques, we carried out measurements of ionic mass spectrum and their energy distribution in order to investigate an atmospheric argon discharge by using a surfatron surface-wave device. The mass and energy distribution measurements were performed with fixed flow rate (2.5 SLM) of pure argon gas (99.999%) and different Ar-O2 gas mixture compositions (99-1, 98-2 and 97-3). The mass spectra and energy distributions were recorded for Ar+, O+, O+ 2, N+ and N2 +. The axial distribution profiles of ionic mass and their energy were obtained for different experimental conditions as a function of the plasma length. The results showed that the peak of the positive ion energy distributions shifted to higher energies and also that the distribution width increased as the distance between the sampling orifice and the launcher gap was increased. It was also found that under certain experimental conditions the ion flux of atomic species were higher than the ion flux of their diatomic counterpart. The motivation of this study was to obtain a better understanding of a surface wave discharge in atmospheric pressure that may play a key role on new second generation biofuel technologies.

  17. High Resolution Mass Spectrometry of Polyfluorinated Polyether-Based Formulation

    NASA Astrophysics Data System (ADS)

    Dimzon, Ian Ken; Trier, Xenia; Frömel, Tobias; Helmus, Rick; Knepper, Thomas P.; de Voogt, Pim

    2016-02-01

    High resolution mass spectrometry (HRMS) was successfully applied to elucidate the structure of a polyfluorinated polyether (PFPE)-based formulation. The mass spectrum generated from direct injection into the MS was examined by identifying the different repeating units manually and with the aid of an instrument data processor. Highly accurate mass spectral data enabled the calculation of higher-order mass defects. The different plots of MW and the nth-order mass defects (up to n = 3) could aid in assessing the structure of the different repeating units and estimating their absolute and relative number per molecule. The three major repeating units were -C2H4O-, -C2F4O-, and -CF2O-. Tandem MS was used to identify the end groups that appeared to be phosphates, as well as the possible distribution of the repeating units. Reversed-phase HPLC separated of the polymer molecules on the basis of number of nonpolar repeating units. The elucidated structure resembles the structure in the published manufacturer technical data. This analytical approach to the characterization of a PFPE-based formulation can serve as a guide in analyzing not just other PFPE-based formulations but also other fluorinated and non-fluorinated polymers. The information from MS is essential in studying the physico-chemical properties of PFPEs and can help in assessing the risks they pose to the environment and to human health.

  18. Aerodynamic mass spectrometry interfacing of microdevices without electrospray tips.

    PubMed

    Grym, Jakub; Otevrel, Marek; Foret, Frantisek

    2006-10-01

    A new concept for electrospray coupling of microfluidic devices with mass spectrometry was developed. The sampling orifice of the time-of-flight mass spectrometer was modified with an external adapter assisting in formation and transport of the electrosprayed plume from the multichannel polycarbonate microdevice. The compact disk sized microdevice was designed with radial channels extending to the circumference of the disk. The electrospray exit ports were formed by the channel openings on the surface of the disk rim. No additional tips at the channel exits were used. Electrospray was initiated directly from the channel openings by applying high voltage between sample wells and the entrance of the external adapter. The formation of the spatially unstable droplet at the electrospray openings was eliminated by air suction provided by a pump connected to the external adapter. Compared with the air intake through the original mass spectrometer sampling orifice, more than an order of magnitude higher flow rate was achieved for efficient transport of the electrospray plume into the mass spectrometer. Additional experiments with electric potentials applied between the entrance sections of the external adapter and the mass spectrometer indicated that the air flow was the dominant transport mechanism. Basic properties of the system were tested using mathematical modeling and characterized using ESI/TOF-MS measurements of peptide and protein samples. PMID:17102844

  19. Electrospray Ionization Tandem Mass Spectrometry of Ammonium Cationized Polyethers

    NASA Astrophysics Data System (ADS)

    Nasioudis, Andreas; Heeren, Ron M. A.; van Doormalen, Irene; de Wijs-Rot, Nicolette; van den Brink, Oscar F.

    2011-05-01

    Quaternary ammonium salts (Quats) and amines are known to facilitate the MS analysis of high molar mass polyethers by forming low charge state adduct ions. The formation, stability, and behavior upon collision-induced dissociation (CID) of adduct ions of polyethers with a variety of Quats and amines were studied by electrospray ionization quadrupole time-of-flight, quadrupole ion trap, and linear ion trap tandem mass spectrometry (MS/MS). The linear ion trap instrument was part of an Orbitrap hybrid mass spectrometer that allowed accurate mass MS/MS measurements. The Quats and amines studied were of different degree of substitution, structure, and size. The stability of the adduct ions was related to the structure of the cation, especially the amine's degree of substitution. CID of singly/doubly charged primary and tertiary ammonium cationized polymers resulted in the neutral loss of the amine followed by fragmentation of the protonated product ions. The latter reveals information about the monomer unit, polymer sequence, and endgroup structure. In addition, the detection of product ions retaining the ammonium ion was observed. The predominant process in the CID of singly charged quaternary ammonium cationized polymers was cation detachment, whereas their doubly charged adduct ions provided the same information as the primary and tertiary ammonium cationized adduct ions. This study shows the potential of specific amines as tools for the structural elucidation of high molar mass polyethers.

  20. Membranoproliferative glomerulonephritis: the role for laser microdissection and mass spectrometry.

    PubMed

    Jain, Deepika; Green, Jamie A; Bastacky, Sheldon; Theis, Jason D; Sethi, Sanjeev

    2014-02-01

    Monoclonal gammopathy is increasingly recognized as a common cause of membranoproliferative glomerulonephritis (MPGN); however, establishing this diagnosis can be challenging. We report the case of a 58-year-old asymptomatic woman who presented with proteinuria with protein excretion of 5,000mg/d, microscopic hematuria, and normal kidney function. Kidney biopsy was consistent with MPGN pattern of injury. Immunofluorescence studies were positive for nonspecific segmental immunoglobulin M (IgM) and C3 staining. Electron microscopy showed subendothelial, subepithelial, and mesangial electron-dense deposits. The workup excluded an infectious or autoimmune disease, but IgG κ monoclonal protein was detected in serum at a concentration of 0.4mg/dL. Because there was a mismatch between the serum monoclonal protein (IgG κ) and immunofluorescence staining pattern (nonspecific IgM, no light chain restriction), laser microdissection and mass spectrometry were performed on the kidney biopsy tissue. This identified the deposits as monoclonal IgG κ, thereby leading to the diagnosis of monoclonal gammopathy-associated MPGN. Our case emphasizes the importance of searching for an underlying cause of MPGN, reviews the technique of laser microdissection-mass spectrometry, and highlights its application as a pathology tool for the evaluation of monoclonal gammopathy-related glomerulonephritis. PMID:24145022

  1. Bio-Aerosol Detection Using Mass Spectrometry: Public Health Applications

    SciTech Connect

    Ludvigson, L D

    2004-03-05

    I recently spent a summer as an intern at the Lawrence Livermore National Laboratory. I worked on a project involving the real-time, reagentless, single cell detection of aerosolized pathogens using a novel mass spectrometry approach called Bio-Aerosol Mass Spectrometry (BAMS). Based upon preliminary results showing the differentiation capabilities of BAMS, I would like to explore the development and use of this novel detection system in the context of both environmental and clinical sample pathogen detection. I would also like to explore the broader public health applications that a system such as BAMS might have in terms of infectious disease prevention and control. In order to appreciate the potential of this instrument, I will demonstrate the need for better pathogen detection methods, and outline the instrumentation, data analysis and preliminary results that lead me toward a desire to explore this technology further. I will also discuss potential experiments for the future along with possible problems that may be encountered along the way.

  2. Use of Tritium Accelerator Mass Spectrometry for Tree Ring Analysis

    PubMed Central

    LOVE, ADAM H.; HUNT, JAMES R.; ROBERTS, MARK L.; SOUTHON, JOHN R.; CHIARAPPA - ZUCCA, MARINA L.; DINGLEY, KAREN H.

    2010-01-01

    Public concerns over the health effects associated with low-level and long-term exposure to tritium released from industrial point sources have generated the demand for better methods to evaluate historical tritium exposure levels for these communities. The cellulose of trees accurately reflects the tritium concentration in the source water and may contain the only historical record of tritium exposure. The tritium activity in the annual rings of a tree was measured using accelerator mass spectrometry to reconstruct historical annual averages of tritium exposure. Milligram-sized samples of the annual tree rings from a Tamarix located at the Nevada Test Site are used for validation of this methodology. The salt cedar was chosen since it had a single source of tritiated water that was well-characterized as it varied over time. The decay-corrected tritium activity of the water in which the salt cedar grew closely agrees with the organically bound tritium activity in its annual rings. This demonstrates that the milligram-sized samples used in tritium accelerator mass spectrometry are suited for reconstructing anthropogenic tritium levels in the environment. PMID:12144257

  3. Data-independent microbial metabolomics with ambient ionization mass spectrometry.

    PubMed

    Rath, Christopher M; Yang, Jane Y; Alexandrov, Theodore; Dorrestein, Pieter C

    2013-08-01

    Atmospheric ionization methods are ideally suited for prolonged MS/MS analysis. Data-independent MS/MS is a complementary technique for analysis of biological samples as compared to data-dependent analysis. Here, we pair data-independent MS/MS with the ambient ionization method nanospray desorption electrospray ionization (nanoDESI) for untargeted analysis of bacterial metabolites. Proof-of-principle data and analysis are illustrated by sampling Bacillus subtilis and Pseudomonas aeruginosa directly from Petri dishes. We found that this technique enables facile comparisons between strains via MS and MS/MS plots which can be translated to chemically informative molecular maps through MS/MS networking. The development of novel techniques to characterize microbial metabolites allows rapid and efficient analysis of metabolic exchange factors. This is motivated by our desire to develop novel techniques to explore the role of interspecies interactions in the environment, health, and disease. This is a contribution to honor Professor Catherine C. Fenselau in receiving the prestigious ASMS Award for a Distinguished Contribution in Mass Spectrometry for her pioneering work on microbial mass spectrometry. PMID:23568029

  4. Mass spectrometry-based proteomics: existing capabilities and future directions

    SciTech Connect

    Angel, Thomas E.; Aryal, Uma K.; Hengel, Shawna M.; Baker, Erin Shammel; Kelly, Ryan T.; Robinson, Errol W.; Smith, Richard D.

    2012-05-21

    Mass spectrometry-based proteomics provides a means for identification, characterization, and quantification of biomolecules that are integral components of the processes essential for life. Characterization of proteins present in a biological system at the proteome and sub-proteomes (e.g., the phosphoproteome, proteoglycome, or degradome/peptidome) levels provides a foundation for understanding fundamental aspects as well as potentially a range of translational applications. Emerging technologies such as ion mobility separations coupled with mass spectrometry and microchip-based - proteome measurements combined with continued enhancement of MS instrumentation and separation techniques, such as reversed phase liquid chromatography and potentially capillary electrophoresis, show great promise for both broad undirected as well as targeted measurements and will be critical for e.g., the proteome-wide characterization of post translational modifications and identification, or the verification, and validation of potential biomarkers of disease. MS-based proteomics is also increasingly demonstrating great potential for contributing to our understanding of the dynamics, reactions, and roles proteins and peptides play advancing our understanding of biology on a system wide level for a wide range of applications, from investigations of microbial communities, bioremediation, and human health and disease states alike.

  5. Use of tritium accelerator mass spectrometry for tree ring analysis.

    PubMed

    Love, Adam H; Hunt, James R; Roberts, Mark L; Southon, John R; Chiarapp-Zucca, Marina L; Dingley, Karen H

    2002-07-01

    Public concerns over the health effects associated with low-level and long-term exposure to tritium released from industrial point sources have generated the demand for better methods to evaluate historical tritium exposure levels for these communities. The cellulose of trees accurately reflects the tritium concentration in the source water and may contain the only historical record of tritium exposure. The tritium activity in the annual rings of a tree was measured using accelerator mass spectrometry to reconstruct historical annual averages of tritium exposure. Milligram-sized samples of the annual tree rings from a Tamarix located at the Nevada Test Site are used for validation of this methodology. The salt cedar was chosen since it had a single source of tritiated water that was well-characterized as it varied over time. The decay-corrected tritium activity of the water in which the salt cedar grew closely agrees with the organically bound tritium activity in its annual rings. This demonstrates that the milligram-sized samples used in tritium accelerator mass spectrometry are suited for reconstructing anthropogenic tritium levels in the environment. PMID:12144257

  6. Data-Independent Microbial Metabolomics with Ambient Ionization Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Rath, Christopher M.; Yang, Jane Y.; Alexandrov, Theodore; Dorrestein, Pieter C.

    2013-08-01

    Atmospheric ionization methods are ideally suited for prolonged MS/MS analysis. Data-independent MS/MS is a complementary technique for analysis of biological samples as compared to data-dependent analysis. Here, we pair data-independent MS/MS with the ambient ionization method nanospray desorption electrospray ionization (nanoDESI) for untargeted analysis of bacterial metabolites. Proof-of-principle data and analysis are illustrated by sampling Bacillus subtilis and Pseudomonas aeruginosa directly from Petri dishes. We found that this technique enables facile comparisons between strains via MS and MS/MS plots which can be translated to chemically informative molecular maps through MS/MS networking. The development of novel techniques to characterize microbial metabolites allows rapid and efficient analysis of metabolic exchange factors. This is motivated by our desire to develop novel techniques to explore the role of interspecies interactions in the environment, health, and disease. This is a contribution to honor Professor Catherine C. Fenselau in receiving the prestigious ASMS Award for a Distinguished Contribution in Mass Spectrometry for her pioneering work on microbial mass spectrometry.

  7. NMR and mass spectrometry of phosphorus in wetlands

    USGS Publications Warehouse

    El-Rifai, H.; Heerboth, M.; Gedris, T.E.; Newman, S.; Orem, W.; Cooper, W.T.

    2008-01-01

    There is at present little information on the long-term stability of phosphorus sequestered in wetlands. Phosphorus sequestered during high loading periods may be relatively unstable and easily remobilized following changes in nutrient status or hydrological regime, but the chemical forms of sequestered phosphorus that do remobilize are largely unknown at this time. A lack of suitable analytical techniques has contributed to this dearth of knowledge regarding the stability of soil organic phosphorus. We analysed phosphorus in soils from the 'head' of Rescue Strand tree island and an adjacent marsh in the Florida Everglades by 31P nuclear magnetic resonance (NMR) spectroscopy and high-resolution mass spectrometry. Tree islands are important areas of biodiversity within the Everglades and offer a unique opportunity to study phosphorus sequestration because they are exposed to large phosphorus loads and appear to be natural nutrient sinks. The 31P NMR profiling of extracts from surface and sediment samples in the tree island indicates that phosphorus input to Rescue Strand tree island soils is mostly in the form of inorganic ortho-phosphate and is either refractory when deposited or rapidly recycled by the native vegetation into a stable phosphorus pool largely resistant to re-utilization by plants or microbes. Mass spectrometry revealed the presence of inositol hexakisphosphate, a common organic monophosphate ester not previously observed in Everglades' soils. ?? 2008 The Authors.

  8. High-resolution mass spectrometry for detecting Acetylcholine in Arabidopsis

    PubMed Central

    Murata, Jun; Watanabe, Takehiro; Sugahara, Kohtaro; Yamagaki, Tohru; Takahashi, Toshio

    2015-01-01

    Acetylcholine (ACh) was first identified a century ago, and has long been known as a neurotransmitter in animals. However, it has been shown recently that the occurrence of ACh is widespread among various non-animal species including higher plants. Although previous reports suggest that various plant species are capable of responding to exogenously applied ACh, the molecular basis for ACh biosynthesis and regulatory mechanisms mediated by endogenous ACh are largely unclear. This is partly because of the lack of conclusive data on the occurrence and the tissue specificity of ACh in plants. To this end, we performed various analyses including liquid chromatography electro-chemical detection (LC-ECD), liquid chromatography tandem mass spectrometry (LC-MS/MS) analysis. The results, together with electrospray ionization-orbitrap Fourier transform mass spectrometry (ESI-orbitrap FT-MS) analysis provide strong evidence that ACh exists in Arabidopsis thaliana tissues. The results also showed that the level of ACh is highest in seed, followed by root and cotyledon. Moreover, exogenously applied ACh inhibited the elongation of Arabidopsis root hairs. These results collectively indicate that ACh exists primarily in seed and root in Arabidopsis seedlings, and plays a pivotal role during the initial stages of seedling development by controlling root hair elongation in Arabidopsis. PMID:26237653

  9. Detection of gaseous organophosphorus compounds using secondary ion mass spectrometry

    SciTech Connect

    Groenewold, G.S.; Todd, P.J.

    1985-04-01

    Molecular secondary ion mass spectrometry (SIMS) has been investigated for sensitivity and selectivity in the analysis of gaseous organophosphorus compounds. Abundant analyte ions were observed when the gaseous organophosphorus compounds were admitted into the secondary ion source, where a matrix was under primary ion bombardment. The best matrix for the detection of dimethyl methylphosphonate (DMMP), trimethyl phosphate (TMP), and diisopropyl methylphosphonate (DIMP) was determined to be polyphosphoric acid. The abundance of secondary analyte ions was observed to be linear with the introduction rate of gaseous analyte. The introduction rate necessary to produce a 3:1 signal-to-noise ratio in the intensity of secondary protonated molecular ions from DMMP was estimated to be 4 x 10/sup -11/ mols/sup -1/. Substantially more analyte fragmentation is observed by using SIMS than by using methane chemical ionization mass spectrometry. Ten compounds representative of other compound classes were investigated in the same manner as the organic phosphonates; characteristic secondary protonated molecular ions were detected from amines only.

  10. Mass Spectrometry Imaging for Dissecting Steroid Intracrinology within Target Tissues

    PubMed Central

    Cobice, Diego F.; Mackay, C. Logan; Goodwin, Richard J. A.; McBride, Andrew; Langridge-Smith, Patrick R.; Webster, Scott P.; Walker, Brian R.; Andrew, Ruth

    2015-01-01

    Steroid concentrations within tissues are modulated by intracellular enzymes. Such ‘steroid intracrinology’ influences hormone-dependent cancers and obesity, and provides targets for pharmacological inhibition. However, no high resolution methods exist to quantify steroids within target tissues. We developed mass spectrometry imaging (MSI), combining matrix assisted laser desorption ionization with on-tissue derivatization with Girard T and Fourier Transform Ion Cyclotron Resonance Mass Spectrometry, to quantify substrate and product (11-dehydrocorticosterone and corticosterone) of the glucocorticoid-amplifying enzyme 11β-HSD1. Regional steroid distribution was imaged at 150-200μm resolution in rat adrenal gland and mouse brain sections, and confirmed with collision induced dissociation/liquid extraction surface analysis. In brains of mice with 11β-HSD1 deficiency or inhibition, MSI quantified changes in sub-regional corticosterone/11-dehydrocorticosterone ratio, distribution of inhibitor, and accumulation of the alternative 11β-HSD1 substrate, 7-ketocholesterol. MSI data correlated well with LC-MS/MS in whole brain homogenates. MSI with derivatization is a powerful new tool to investigate steroid biology within tissues. PMID:24134553

  11. Sequence analysis of styrenic copolymers by tandem mass spectrometry.

    PubMed

    Yol, Aleer M; Janoski, Jonathan; Quirk, Roderic P; Wesdemiotis, Chrys

    2014-10-01

    Styrene and smaller molar amounts of either m-dimethylsilylstyrene (m-DMSS) or p-dimethylsilylstyrene (p-DMSS) were copolymerized under living anionic polymerization conditions, and the compositions, architectures, and sequences of the resulting copolymers were characterized by matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS) and tandem mass spectrometry (MS(2)). MS analysis revealed that linear copolymer chains containing phenyl-Si(CH3)2H pendants were the major product for both DMSS comonomers. In addition, two-armed architectures with phenyl-Si(CH3)2-benzyl branches were detected as minor products. The comonomer sequence in the linear chains was established by MS(2) experiments on lithiated oligomers, based on the DMSS content of fragments generated by backbone C-C bond scissions and with the help of reference MS(2) spectra obtained from a polystyrene homopolymer and polystyrene end-capped with a p-DMSS block. The MS(2) data provided conclusive evidence that copolymerization of styrene/DMSS mixtures leads to chains with a rather random distribution of the silylated comonomer when m-DMSS is used, but to chains with tapered block structures, with the silylated units near the initiator, when p-DMSS is used. Hence, MS(2) fragmentation patterns permit not only differentiation of the sequences generated in the synthesis, but also the determination of specific comonomer locations along the polymer chain. PMID:25181590

  12. Quantitation of DNA adducts by stable isotope dilution mass spectrometry

    PubMed Central

    Tretyakova, Natalia; Goggin, Melissa; Janis, Gregory

    2012-01-01

    Exposure to endogenous and exogenous chemicals can lead to the formation of structurally modified DNA bases (DNA adducts). If not repaired, these nucleobase lesions can cause polymerase errors during DNA replication, leading to heritable mutations potentially contributing to the development of cancer. Due to their critical role in cancer initiation, DNA adducts represent mechanism-based biomarkers of carcinogen exposure, and their quantitation is particularly useful for cancer risk assessment. DNA adducts are also valuable in mechanistic studies linking tumorigenic effects of environmental and industrial carcinogens to specific electrophilic species generated from their metabolism. While multiple experimental methodologies have been developed for DNA adduct analysis in biological samples – including immunoassay, HPLC, and 32P-postlabeling – isotope dilution high performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS) generally has superior selectivity, sensitivity, accuracy, and reproducibility. As typical DNA adducts concentrations in biological samples are between 0.01 – 10 adducts per 108 normal nucleotides, ultrasensitive HPLC-ESI-MS/MS methodologies are required for their analysis. Recent developments in analytical separations and biological mass spectrometry – especially nanoflow HPLC, nanospray ionization MS, chip-MS, and high resolution MS – have pushed the limits of analytical HPLC-ESI-MS/MS methodologies for DNA adducts, allowing researchers to accurately measure their concentrations in biological samples from patients treated with DNA alkylating drugs and in populations exposed to carcinogens from urban air, drinking water, cooked food, alcohol, and cigarette smoke. PMID:22827593

  13. Analysis of hazardous biological material by MALDI mass spectrometry

    SciTech Connect

    KL Wahl; KH Jarman; NB Valentine; MT Kingsley; CE Petersen; ST Cebula; AJ Saenz

    2000-03-21

    Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-MS) has become a valuable tool for analyzing microorganisms. The speed with which data can be obtained from MALDI-MS makes this a potentially important tool for biological health hazard monitoring and forensic applications. The excitement in the mass spectrometry community in this potential field of application is evident by the expanding list of research laboratories pursuing development of MALDI-MS for bacterial identification. Numerous research groups have demonstrated the ability to obtain unique MALDI-MS spectra from intact bacterial cells and bacterial cell extracts. The ability to differentiate strains of the same species has been investigated. Reproducibility of MALDI-MS spectra from bacterial species under carefully controlled experimental conditions has also been demonstrated. Wang et al. have reported on interlaboratory reproducibility of the MALDI-MS analysis of several bacterial species. However, there are still issues that need to be addressed, including the careful control of experimental parameters for reproducible spectra and selection of optimal experimental parameters such as solvent and matrix.

  14. High Resolution MALDI Imaging Mass Spectrometry of Retinal Tissue Lipids

    NASA Astrophysics Data System (ADS)

    Anderson, David M. G.; Ablonczy, Zsolt; Koutalos, Yiannis; Spraggins, Jeffrey; Crouch, Rosalie K.; Caprioli, Richard M.; Schey, Kevin L.

    2014-08-01

    Matrix assisted laser desorption ionization imaging mass spectrometry (MALDI IMS) has the ability to provide an enormous amount of information on the abundances and spatial distributions of molecules within biological tissues. The rapid progress in the development of this technology significantly improves our ability to analyze smaller and smaller areas and features within tissues. The mammalian eye has evolved over millions of years to become an essential asset for survival, providing important sensory input of an organism's surroundings. The highly complex sensory retina of the eye is comprised of numerous cell types organized into specific layers with varying dimensions, the thinnest of which is the 10 μm retinal pigment epithelium (RPE). This single cell layer and the photoreceptor layer contain the complex biochemical machinery required to convert photons of light into electrical signals that are transported to the brain by axons of retinal ganglion cells. Diseases of the retina, including age-related macular degeneration (AMD), retinitis pigmentosa, and diabetic retinopathy, occur when the functions of these cells are interrupted by molecular processes that are not fully understood. In this report, we demonstrate the use of high spatial resolution MALDI IMS and FT-ICR tandem mass spectrometry in the Abca4 -/- knockout mouse model of Stargardt disease, a juvenile onset form of macular degeneration. The spatial distributions and identity of lipid and retinoid metabolites are shown to be unique to specific retinal cell layers.

  15. Increasing Protein Charge State When Using Laser Electrospray Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Karki, Santosh; Flanigan, Paul M.; Perez, Johnny J.; Archer, Jieutonne J.; Levis, Robert J.

    2015-05-01

    Femtosecond (fs) laser vaporization is used to transfer cytochrome c, myoglobin, lysozyme, and ubiquitin from the condensed phase into an electrospray (ES) plume consisting of a mixture of a supercharging reagent, m-nitrobenzyl alcohol ( m-NBA), and trifluoroacetic acid (TFA), acetic acid (AA), or formic acid (FA). Interaction of acid-sensitive proteins like cytochrome c and myoglobin with the highly charged ES droplets resulted in a shift to higher charge states in comparison with acid-stable proteins like lysozyme and ubiquitin. Laser electrospray mass spectrometry (LEMS) measurements showed an increase in both the average charge states (Zavg) and the charge state with maximum intensity (Zmode) for acid-sensitive proteins compared with conventional electrospray ionization mass spectrometry (ESI-MS) under equivalent solvent conditions. A marked increase in ion abundance of higher charge states was observed for LEMS in comparison with conventional electrospray for cytochrome c (ranging from 19+ to 21+ versus 13+ to 16+) and myoglobin (ranging from 19+ to 26+ versus 18+ to 21+) using an ES solution containing m-NBA and TFA. LEMS measurements as a function of electrospray flow rate yielded increasing charge states with decreasing flow rates for cytochrome c and myoglobin.

  16. Computational Methods for Protein Identification from Mass Spectrometry Data

    PubMed Central

    McHugh, Leo; Arthur, Jonathan W

    2008-01-01

    Protein identification using mass spectrometry is an indispensable computational tool in the life sciences. A dramatic increase in the use of proteomic strategies to understand the biology of living systems generates an ongoing need for more effective, efficient, and accurate computational methods for protein identification. A wide range of computational methods, each with various implementations, are available to complement different proteomic approaches. A solid knowledge of the range of algorithms available and, more critically, the accuracy and effectiveness of these techniques is essential to ensure as many of the proteins as possible, within any particular experiment, are correctly identified. Here, we undertake a systematic review of the currently available methods and algorithms for interpreting, managing, and analyzing biological data associated with protein identification. We summarize the advances in computational solutions as they have responded to corresponding advances in mass spectrometry hardware. The evolution of scoring algorithms and metrics for automated protein identification are also discussed with a focus on the relative performance of different techniques. We also consider the relative advantages and limitations of different techniques in particular biological contexts. Finally, we present our perspective on future developments in the area of computational protein identification by considering the most recent literature on new and promising approaches to the problem as well as identifying areas yet to be explored and the potential application of methods from other areas of computational biology. PMID:18463710

  17. Multiphoton ionization mass spectrometry of nitrated polycyclic aromatic hydrocarbons.

    PubMed

    Tang, Yuanyuan; Imasaka, Tomoko; Yamamoto, Shigekazu; Imasaka, Totaro

    2015-08-01

    In order to suppress the fragmentation and improve the sensitivity for determination of nitrated polycyclic aromatic hydrocarbons (NPAHs), the mechanism of multiphoton ionization was studied for the following representative NPAHs, 9-nitroanthracene, 3-nitrofluoranthene, and 1-nitropyrene. The analytes were extracted from the PM2.5 on the sampling filter ultrasonically, and were measured using gas chromatography/multiphoton ionization/time-of-flight mass spectrometry with a femtosecond tunable laser in the range from 267 to 405 nm. As a result, a molecular ion was observed as the major ion and fragmentation was suppressed at wavelengths longer than 345 nm. Furthermore, the detection limit measured at 345 nm was measured to be the subpicogram level. The organic compounds were extracted from a 2.19 mg sample of particulate matter 2.5 (PM2.5), and the extract was subjected to multiphoton ionization mass spectrometry after gas chromatograph separation. The background signals were drastically suppressed at 345 nm, and the target NPAHs, including 9-nitroanthracene and 1-nitropyrene, were detected, and their concentrations were determined to be 5 and 3 pg/m(3), respectively. PMID:26048831

  18. Unexpected Analyte Oxidation during Desorption Electrospray Ionization - Mass Spectrometry

    SciTech Connect

    Pasilis, Sofie P; Kertesz, Vilmos; Van Berkel, Gary J

    2008-01-01

    During the analysis of surface spotted analytes using desorption electrospray ionization mass spectrometry (DESI-MS), abundant ions are sometimes observed that appear to be the result of oxygen addition reactions. In this investigation, the effect of sample aging, the ambient lab environment, spray voltage, analyte surface concentration, and surface type on this oxidative modification of spotted analytes, exemplified by tamoxifen and reserpine, during analysis by desorption electrospray ionization mass spectrometry was studied. Simple exposure of the samples to air and to ambient lighting increased the extent of oxidation. Increased spray voltage lead also to increased analyte oxidation, possibly as a result of oxidative species formed electrochemically at the emitter electrode or in the gas - phase by discharge processes. These oxidative species are carried by the spray and impinge on and react with the sampled analyte during desorption/ionization. The relative abundance of oxidized species was more significant for analysis of deposited analyte having a relatively low surface concentration. Increasing spray solvent flow rate and addition of hydroquinone as a redox buffer to the spray solvent were found to decrease, but not entirely eliminate, analyte oxidation during analysis. The major parameters that both minimize and maximize analyte oxidation were identified and DESI-MS operational recommendations to avoid these unwanted reactions are suggested.

  19. Colors for molecular masses: fusion of spectroscopy and mass spectrometry for identification of biomolecules.

    PubMed

    Kopysov, Vladimir; Makarov, Alexander; Boyarkin, Oleg V

    2015-01-01

    We present an approach that integrates ultraviolet (UV) photofragmentation spectroscopy of cold ions with high-resolution Orbitrap mass spectrometry (MS) and uses mathematical analysis of the recorded 2D data arrays for structural identification of biomolecules. The synergy of the two orthogonal techniques makes these arrays unique fingerprints of molecular ions, enabling their reliable identifications. Using preliminary created libraries of fingerprints, the UV-MS approach was successfully applied for quantitative identification of exact isobaric molecules in their mixtures, which is one of the challenging cases for mass spectrometry. We also demonstrate how the UV and fragmentation mass spectra of unknown chemical components of a mixture can be recovered from its fingerprint even without a use of library. PMID:25844804

  20. Charge Detection Mass Spectrometry with Almost Perfect Charge Accuracy.

    PubMed

    Keifer, David Z; Shinholt, Deven L; Jarrold, Martin F

    2015-10-20

    Charge detection mass spectrometry (CDMS) is a single-particle technique where the masses of individual ions are determined from simultaneous measurement of each ion's mass-to-charge ratio (m/z) and charge. CDMS has many desirable features: it has no upper mass limit, no mass discrimination, and it can analyze complex mixtures. However, the charge is measured directly, and the poor accuracy of the charge measurement has severely limited the mass resolution achievable with CDMS. Since the charge is quantized, it needs to be measured with sufficient accuracy to assign each ion to its correct charge state. This goal has now been largely achieved. By reducing the pressure to extend the trapping time and by implementing a novel analysis method that improves the signal-to-noise ratio and compensates for imperfections in the charge measurement, the uncertainty has been reduced to less than 0.20 e rmsd (root-mean-square deviation). With this unprecedented precision peaks due to different charge states are resolved in the charge spectrum. Further improvement can be achieved by quantizing the charge (rounding the measured charge to the nearest integer) and culling ions with measured charges midway between the integral values. After ions with charges more than one standard deviation from the mean are culled, the fraction of ions assigned to the wrong charge state is estimated to be 6.4 × 10(-5) (i.e., less than 1 in 15 000). Since almost all remaining ions are assigned to their correct charge state, the uncertainty in the mass is now almost entirely limited by the uncertainty in the m/z measurement. PMID:26418830

  1. Resolution of time-of-flight mass spectrometers evaluated for secondary neutral mass spectrometry

    NASA Astrophysics Data System (ADS)

    Kato, Makoto; Mogami, Akinori; Naito, Motohiro; Ichimura, Shingo; Shimizu, Hazime

    1988-09-01

    Mass resolution of a time-of-flight mass spectrometer with a two-stage electrostatic reflector is calculated for secondary neutral mass spectrometry. The instrument parameters are optimized for energy and space focusing: correcting the flight time difference due to the energy width ΔE of sputtered particles and the spatial width Δs of an ionizing laser beam. The effect of Δs can be compensated by applying an acceleration field to the ionizing region, and the maximum resolution becomes about 1000 for ΔE=10 eV and Δs=1.0 mm.

  2. High-Sensitivity Ion Mobility Spectrometry/Mass Spectrometry Using Electrodynamic Ion Funnel Interfaces

    PubMed Central

    Tang, Keqi; Shvartsburg, Alexandre A.; Lee, Hak-No; Prior, David C.; Buschbach, Michael A.; Li, Fumin; Tolmachev, Aleksey; Anderson, Gordon A.; Smith, Richard D.

    2007-01-01

    The utility of ion mobility spectrometry (IMS) for separation of mixtures and structural characterization of ions has been demonstrated extensively, including in the biological and nanoscience contexts. A major attraction of IMS is its speed, several orders of magnitude greater than that of condensed-phase separations. Nonetheless, IMS combined with mass spectrometry (MS) has remained a niche technique, substantially because of limited sensitivity resulting from ion losses at the IMS-MS junction. We have developed a new electrospray ionization (ESI)-IMS-QToF MS instrument that incorporates electrodynamic ion funnels at both front ESI-IMS and rear IMS-QToF interfaces. The front funnel is of the novel “hourglass” design that efficiently accumulates ions and pulses them into the IMS drift tubes. Even for drift tubes of two meter length, ion transmission through IMS and on to QToF is essentially lossless across the range of ion masses relevant to most applications. The RF ion focusing at the IMS terminus does not degrade IMS resolving power, which exceeds 100 (for singly-charged ions) and is close to the theoretical limit. The overall sensitivity of present ESI-IMS-MS system is comparable to that of commercial ESI-MS, which should make IMS-MS suitable for analyses of complex mixtures with ultra-high sensitivity and exceptional throughput. PMID:15889926

  3. High-Sensitivity Ion Mobility Spectrometry/Mass Spectrometry Using Electrodynamic Ion Funnel Interfaces

    SciTech Connect

    Tang, Keqi; Shvartsburg, Alexandre A.; Lee, Hak-No; Prior, David C.; Buschbach, Michael A.; Li, Fumin; Tolmachev, Aleksey V.; Anderson, Gordon A.; Smith, Richard D.

    2005-05-15

    The utility of ion mobility spectrometry (IMS) for separation of mixtures and structural characterization of ions has been demonstrated extensively, including in the biological and nanoscience contexts. A major attraction of IMS is its speed, several orders of magnitude above that of condensed-phase separations. Nonetheless, IMS combined with mass spectrometry (MS) has remained a niche technique, substantially due to limited sensitivity resulting from ion losses at the IMS-MS junction. We have developed a new electrospray ionization (ESI)-IMS-QToF MS instrument that incorporates electrodynamic ion funnels at both front ESI-IMS and back IMS-QToF interfaces. The front funnel is of the novel ''hourglass'' design that efficiently accumulates ions and pulses them into the IMS drift tubes. Even for drift tubes of two meter length, ion transmission through IMS and on to QToF is essentially lossless across the range of ion masses relevant to most applications. The RF ion focusing at IMS terminus does not degrade IMS resolving power, which exceeds 100 (for singly-charged ions) and is close to the theoretical limit. The overall sensitivity of present ESI-IMS-MS system is shown to be comparable to that of commercial ESI-MS, which should make IMS-MS suitable for analyses of complex mixtures with ultra-high sensitivity and exceptional throughput.

  4. Combining ion mobility spectrometry, mass spectrometry, and photoelectron spectroscopy in a high-transmission instrument.

    PubMed

    Vonderach, Matthias; Ehrler, Oli T; Weis, Patrick; Kappes, Manfred M

    2011-02-01

    We have developed a novel instrument that combines ion mobility spectrometry, mass spectro-metry, and photoelectron spectroscopy. The instrument couples an electrospray ion source, a high-transmission ion mobility cell based on ion funnels, a quadrupole mass filter, and a time-of-flight (magnetic bottle) photoelectron spectrometer operated with a pulsed detachment laser. We show that the instrument can resolve highly structured anion arrival time distributions and at the same time provide corresponding photoelectron spectra-using the DNA oligonucleotide ion [dC(6) - 5H](5-) as a test case. For this multianion we find at least four different, noninterconverting isomers (conformers) simultaneously present in the gas phase at room temperature. For each of these we record well-resolved and remarkably different photoelectron spectra at each of three different detachment laser wavelengths. Two-dimensional ion mobility/electron binding energy plots can be acquired with an automated data collection procedure. We expect that this kind of instrument will significantly improve the capabilities for structure determination of (bio)molecular anions in the gas phase. PMID:21214198

  5. Non-target screening of veterinary drugs using tandem mass spectrometry on SmartMass.

    PubMed

    Xia, Bing; Liu, Xin; Gu, Yu-Cheng; Zhang, Zhao-Hui; Wang, Hai-Yan; Ding, Li-Sheng; Zhou, Yan

    2013-05-01

    Non-target screening of veterinary drugs using tandem mass spectrometric data was performed on the SmartMass platform. This newly developed software uses the characteristic fragmentation patterns (CFP) to identify chemicals, especially those containing particular substructures. A mixture of 17 sulfonamides was separated by ultra performance liquid chromatography (UPLC), and SmartMass was used to process the tandem mass spectrometry (MS/MS) data acquired on an Orbitrap mass spectrometer. The data were automatically extracted, and each sulfonamide was recognized and analyzed with a prebuilt analysis rule. By using this software, over 98% of the false candidate structures were eliminated, and all the correct structures were found within the top 10 of the ranking lists. Furthermore, SmartMass could also be used to identify slightly modified contraband drugs and metabolites with simple prebuilt rules. PMID:23532781

  6. Non-Target Screening of Veterinary Drugs Using Tandem Mass Spectrometry on SmartMass

    NASA Astrophysics Data System (ADS)

    Xia, Bing; Liu, Xin; Gu, Yu-Cheng; Zhang, Zhao-Hui; Wang, Hai-Yan; Ding, Li-Sheng; Zhou, Yan

    2013-05-01

    Non-target screening of veterinary drugs using tandem mass spectrometric data was performed on the SmartMass platform. This newly developed software uses the characteristic fragmentation patterns (CFP) to identify chemicals, especially those containing particular substructures. A mixture of 17 sulfonamides was separated by ultra performance liquid chromatography (UPLC), and SmartMass was used to process the tandem mass spectrometry (MS/MS) data acquired on an Orbitrap mass spectrometer. The data were automatically extracted, and each sulfonamide was recognized and analyzed with a prebuilt analysis rule. By using this software, over 98 % of the false candidate structures were eliminated, and all the correct structures were found within the top 10 of the ranking lists. Furthermore, SmartMass could also be used to identify slightly modified contraband drugs and metabolites with simple prebuilt rules. [Figure not available: see fulltext.

  7. Direct Analysis in Real Time (DART) of an Organothiophosphate at Ultrahigh Resolution by Fourier Transform Ion Cyclotron Resonance Mass Spectrometry and Tandem Mass Spectrometry

    PubMed Central

    Prokai, Laszlo; Stevens, Stanley M.

    2016-01-01

    Direct analysis in real time (DART) is a recently developed ambient ionization technique for mass spectrometry to enable rapid and sensitive analyses with little or no sample preparation. After swab-based field sampling, the organothiophosphate malathion was analyzed using DART-Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry (MS) and tandem mass spectrometry (MS/MS). Mass resolution was documented to be over 800,000 in full-scan MS mode and over 1,000,000 for an MS/MS product ion produced by collision-induced dissociation of the protonated analyte. Mass measurement accuracy below 1 ppm was obtained for all DART-generated ions that belonged to the test compound in the mass spectra acquired using only external mass calibration. This high mass measurement accuracy, achievable at present only through FTMS, was required for unequivocal identification of the corresponding molecular formulae. PMID:26784186

  8. Direct Analysis in Real Time (DART) of an Organothiophosphate at Ultrahigh Resolution by Fourier Transform Ion Cyclotron Resonance Mass Spectrometry and Tandem Mass Spectrometry.

    PubMed

    Prokai, Laszlo; Stevens, Stanley M

    2016-01-01

    Direct analysis in real time (DART) is a recently developed ambient ionization technique for mass spectrometry to enable rapid and sensitive analyses with little or no sample preparation. After swab-based field sampling, the organothiophosphate malathion was analyzed using DART-Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry (MS) and tandem mass spectrometry (MS/MS). Mass resolution was documented to be over 800,000 in full-scan MS mode and over 1,000,000 for an MS/MS product ion produced by collision-induced dissociation of the protonated analyte. Mass measurement accuracy below 1 ppm was obtained for all DART-generated ions that belonged to the test compound in the mass spectra acquired using only external mass calibration. This high mass measurement accuracy, achievable at present only through FTMS, was required for unequivocal identification of the corresponding molecular formulae. PMID:26784186

  9. Preparation of single cells for imaging mass spectrometry.

    PubMed

    Berman, Elena S F; Fortson, Susan L; Kulp, Kristen S

    2010-01-01

    Characterizing the molecular contents of individual cells is critical for understanding fundamental mechanisms of biological processes. Imaging mass spectrometry (IMS) of biological systems has been steadily gaining popularity for its ability to create precise chemical images of biological samples, thereby revealing new biological insights and improving understanding of disease. In order to acquire mass spectral images from single cells that contain relevant molecular information, samples must be prepared such that cell-culture components, especially salts, are eliminated from the cell surface and that the cell contents are accessible to the mass spectrometer. We have demonstrated a cellular preparation technique for IMS that preserves the basic morphology of cultured cells, allows mass spectrometric chemical profiling of cytosol, and removes the majority of the interfering species derived from the cellular growth medium. Using this protocol, we achieve high-quality, reproducible IMS images from three diverse cell types: MCF7 human breast cancer cells, Madin-Darby canine kidney (MDCK) cells, and NIH/3T3 mouse fibroblasts. This preparation method allows rapid and routine IMS analysis of cultured cells, making possible a wide variety of experiments to further scientific understanding of molecular processes within individual cells. PMID:20680596

  10. Inductively Coupled Plasma Zoom-Time-of-Flight Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Dennis, Elise A.; Ray, Steven J.; Enke, Christie G.; Hieftje, Gary M.

    2016-03-01

    A zoom-time-of-flight mass spectrometer has been coupled to an inductively coupled plasma (ICP) ionization source. Zoom-time-of-flight mass spectrometry (zoom-TOFMS) combines two complementary types of velocity-based mass separation. Specifically, zoom-TOFMS alternates between conventional, constant-energy acceleration (CEA) TOFMS and energy-focused, constant-momentum acceleration (CMA) (zoom) TOFMS. The CMA mode provides a mass-resolution enhancement of 1.5-1.7× over CEA-TOFMS in the current, 35-cm ICP-zoom-TOFMS instrument geometry. The maximum resolving power (full-width at half-maximum) for the ICP-zoom-TOFMS instrument is 1200 for CEA-TOFMS and 1900 for CMA-TOFMS. The CMA mode yields detection limits of between 0.02 and 0.8 ppt, depending upon the repetition rate and integration time—compared with single ppt detection limits for CEA-TOFMS. Isotope-ratio precision is shot-noise limited at approximately 0.2% relative-standard deviation (RSD) for both CEA- and CMA-TOFMS at a 10 kHz repetition rate and an integration time of 3-5 min. When the repetition rate is increased to 43.5 kHz for CMA, the shot-noise limited, zoom-mode isotope-ratio precision is improved to 0.09% RSD for the same integration time.

  11. Protein open-access liquid chromatography/mass spectrometry.

    PubMed

    White, Wendy L; Wagner, Craig D; Hall, John T; Chaney, Erin E; George, Bindu; Hofmann, Karen; Miller, Luke A D; Williams, Jon D

    2005-01-01

    Each year increasing numbers of proteins are submitted for routine characterization by liquid chromatography/mass spectrometry (LC/MS). This paper reports a solution that transforms routine LC/MS analysis of proteins into a fully automated process that significantly reduces analyst intervention. The solution developed, protein open-access (OA) LC/MS, consists of web-enabled sample submission and registration, automated data processing, data interpretation, and report generation. Sample submissions and results are recorded in a LIMS that utilizes an Oracle database. The protein sequence is captured during the sample submission process, stored in the database, and utilized to determine the theoretical protein molecular weight. This calculated mass is used to set the parameters for transformation of the mass-to-charge spectra to the mass domain and evaluate the presence or absence of the desired protein. Three protein OA-LC/MS instruments have been deployed in our facility to support protein characterization, purification, and modification efforts. PMID:15609371

  12. Laser desorption lamp ionization source for ion trap mass spectrometry.

    PubMed

    Wu, Qinghao; Zare, Richard N

    2015-01-01

    A two-step laser desorption lamp ionization source coupled to an ion trap mass spectrometer (LDLI-ITMS) has been constructed and characterized. The pulsed infrared (IR) output of an Nd:YAG laser (1064 nm) is directed to a target inside a chamber evacuated to ~15 Pa causing desorption of molecules from the target's surface. The desorbed molecules are ionized by a vacuum ultraviolet (VUV) lamp (filled with xenon, major wavelength at 148 nm). The resulting ions are stored and detected in a three-dimensional quadrupole ion trap modified from a Finnigan Mat LCQ mass spectrometer operated at a pressure of ≥ 0.004 Pa. The limit of detection for desorbed coronene molecules is 1.5 pmol, which is about two orders of magnitude more sensitive than laser desorption laser ionization mass spectrometry using a fluorine excimer laser (157 nm) as the ionization source. The mass spectrum of four standard aromatic compounds (pyrene, coronene, rubrene and 1,4,8,11,15,18,22,25-octabutoxy-29H,31H-phthalocyanine (OPC)) shows that parent ions dominate. By increasing the infrared laser power, this instrument is capable of detecting inorganic compounds. PMID:25601688

  13. Feature selection and machine learning with mass spectrometry data.

    PubMed

    Datta, Susmita

    2013-01-01

    Mass spectrometry has been used in biochemical research for a long time. However, its potential of discovering proteomic biomarkers using protein mass spectra aroused tremendous interest in last few years. In spite of its potential of biomarker discovery, it is recognized that identification of meaningful proteomic features from mass spectra needs careful evaluation. Hence, extracting meaningful feature(s) and discriminating the samples based on these features is still an open area of research. Several research groups are actively involved in making the process as perfect as possible. In this chapter, we provide a review of major contributions toward feature selection and classification of proteomic mass spectra involving MALDI-TOF and SELDI-TOF technology. Moreover, in this updated version of the chapter, we advocate the use of an adaptive ensemble classifier to classify such complex data. No single classification algorithm tends to work well on all data. Also, the performance depends on the performance criteria used to judge several classifiers. Adaptive ensemble classifier which is constructed combining several good classifiers and optimized against an array of performance measures tends to have better predictive performance on the test samples. PMID:23666729

  14. Accelerator Mass Spectrometry of 129I towards its lower limits

    NASA Astrophysics Data System (ADS)

    Vockenhuber, Christof; Casacuberta, Nuria; Christl, Marcus; Synal, Hans-Arno

    2015-10-01

    We present the performance of Accelerator Mass Spectrometry (AMS) of 129I using the low energy facility TANDY of the Laboratory of Ion Beam Physics at ETH Zurich, Switzerland. Running the tandem accelerator at 300 kV in combination with helium as a stripper gas we obtain high transmission of >50% trough the accelerator for 129I ions in charge state 2+, molecules at mass 129 are sufficiently suppressed at appropriate stripper-gas pressures. While the high-energy spectrometer provides excellent suppression of the stable isotope 127I, mass-to-charge state (m/q) interferences are significantly reduced in 2+, allowing for measurements essentially free of background from other masses (isotopes and m/q interferences). The main challenge in the AMS of 129I comes from cross talk between samples in the ion source. With sufficient care low-level samples (129I/127I < 10-13) can be well measured, e.g. Woodward iodine was measured to 129I/127I = (3.4 ± 0.3) × 10-14, demonstrating that low-energy AMS of 129I provides both high overall efficiency and very low background.

  15. Method for predicting peptide detection in mass spectrometry

    DOEpatents

    Kangas, Lars [West Richland, WA; Smith, Richard D [Richland, WA; Petritis, Konstantinos [Richland, WA

    2010-07-13

    A method of predicting whether a peptide present in a biological sample will be detected by analysis with a mass spectrometer. The method uses at least one mass spectrometer to perform repeated analysis of a sample containing peptides from proteins with known amino acids. The method then generates a data set of peptides identified as contained within the sample by the repeated analysis. The method then calculates the probability that a specific peptide in the data set was detected in the repeated analysis. The method then creates a plurality of vectors, where each vector has a plurality of dimensions, and each dimension represents a property of one or more of the amino acids present in each peptide and adjacent peptides in the data set. Using these vectors, the method then generates an algorithm from the plurality of vectors and the calculated probabilities that specific peptides in the data set were detected in the repeated analysis. The algorithm is thus capable of calculating the probability that a hypothetical peptide represented as a vector will be detected by a mass spectrometry based proteomic platform, given that the peptide is present in a sample introduced into a mass spectrometer.

  16. The role of mass spectrometry in medicinal plant research.

    PubMed

    Héthelyi, E; Tétényi, P; Dabi, E; Dános, B

    1987-11-01

    In phytochemical and chemotaxonomic research work mass spectrometry plays an outstandingly important role. Using gas chromatography/mass spectrometry (GC/MS) we established the chemotaxa of Tanacetum vulgare L. Chemotypes with essential oils containing 60-90% of artemisia ketone, carveol, dihydrocarvone, myrtenol, umbellulone, terpinen-4-ol, davanone, and Tagetes species containing various essential oils can be clearly distinguished by their spectra; we examined many variations of Tagetes erecta, T. lucida, T. minuta, T. patula and T. tenuifolia. We have identified alpha-beta-pinene-, 1,8-cineol-, linalool-, camphor-, nerol-, geraniol- and gamma-gurjonene as components of Achillea distans L. Injecting the essential oil direct from the oil-secreting organs of T. minuta plants we identified using GC/MS 6-10 and 16% eugenol from the involucral bract and hypsophyll, respectively, as well as beta-ocimene, dihydrotagetone, tagetone, Z- and E-ocimenones. In the course of studies on essential fatty acids Borago officinalis and Lappula squarrosa were selected from 70 species of the family Boraginaceae to obtain seed oil as a source of gamma-linolenic acid, and for the PG synthesis we isolated several grams of gamma-linolenic acid, as well as C18:4, i.e. octadecatetraenic acid, from L. squarrosa on the basis of the mass spectra. From the seed oil of Aquilegia vulgaris C18:3 (5) from the oil of Limnanthes dougloasii C20:1 (5) and from the seed oils of Delphinium consolida and of Tropaeolum species (T. majus, T. minus, T. peregrinum) C20:1 (11) fatty acids were identified on the basis of spectra. PMID:2962668

  17. Proteogenomic analysis of Mycobacterium tuberculosis by high resolution mass spectrometry.

    PubMed

    Kelkar, Dhanashree S; Kumar, Dhirendra; Kumar, Praveen; Balakrishnan, Lavanya; Muthusamy, Babylakshmi; Yadav, Amit Kumar; Shrivastava, Priyanka; Marimuthu, Arivusudar; Anand, Sridhar; Sundaram, Hema; Kingsbury, Reena; Harsha, H C; Nair, Bipin; Prasad, T S Keshava; Chauhan, Devendra Singh; Katoch, Kiran; Katoch, Vishwa Mohan; Kumar, Prahlad; Chaerkady, Raghothama; Ramachandran, Srinivasan; Dash, Debasis; Pandey, Akhilesh

    2011-12-01

    The genome sequencing of H37Rv strain of Mycobacterium tuberculosis was completed in 1998 followed by the whole genome sequencing of a clinical isolate, CDC1551 in 2002. Since then, the genomic sequences of a number of other strains have become available making it one of the better studied pathogenic bacterial species at the genomic level. However, annotation of its genome remains challenging because of high GC content and dissimilarity to other model prokaryotes. To this end, we carried out an in-depth proteogenomic analysis of the M. tuberculosis H37Rv strain using Fourier transform mass spectrometry with high resolution at both MS and tandem MS levels. In all, we identified 3176 proteins from Mycobacterium tuberculosis representing ~80% of its total predicted gene count. In addition to protein database search, we carried out a genome database search, which led to identification of ~250 novel peptides. Based on these novel genome search-specific peptides, we discovered 41 novel protein coding genes in the H37Rv genome. Using peptide evidence and alternative gene prediction tools, we also corrected 79 gene models. Finally, mass spectrometric data from N terminus-derived peptides confirmed 727 existing annotations for translational start sites while correcting those for 33 proteins. We report creation of a high confidence set of protein coding regions in Mycobacterium tuberculosis genome obtained by high resolution tandem mass-spectrometry at both precursor and fragment detection steps for the first time. This proteogenomic approach should be generally applicable to other organisms whose genomes have already been sequenced for obtaining a more accurate catalogue of protein-coding genes. PMID:21969609

  18. Quantitative liquid chromatography/mass spectrometry/mass spectrometry warfarin assay for in vitro cytochrome P450 studies.

    PubMed

    Zhang, Z Y; King, B M; Wong, Y N

    2001-11-01

    A sensitive assay using high-performance liquid chromatography tandem mass spectrometry (MS/MS) has been established for the quantitative analysis of cytochrome P450 form-specific activities using warfarin as a probe substrate. Four metabolites, 6-, 7-, 8-, and 10-hydroxywarfarin, were chromatographically resolved within 10 min using gradient mobile phases. The mass spectrometry was operated under negative ionization mode. The MS/MS product ion spectra of warfarin and the metabolites were generated using collision-activated dissociation and interpreted. The abundant product ions of the metabolites were selected for quantification applying multiple reaction monitoring. Quantification was based on a quadratic or power curve of the peak area ratio of the metabolite over the internal standard against the respective concentration of the metabolite. This assay has been validated from 2 to 1000 nM for 10-hydroxywarfarin and from 2 to 5000 nM for 6-, 7-, and 8-hydroxywarfarin and successfully applied to evaluate cytochrome P450-mediated drug-drug interactions in vitro using human hepatocytes and liver microsomal preparations. PMID:11673893

  19. Characterization of methyl methacrylate oligomers using secondary ion mass spectrometry, APCI mass spectrometry and molecular orbital theory

    NASA Astrophysics Data System (ADS)

    Takeuchi, T.; Iwai, K.; Momoji, K.; Miyamoto, I.; Saiki, K.; Hashimoto, K.

    2003-01-01

    The ionization efficiency and fragmentation mechanism of methyl methacrylate (MMA) oligomers (3-mer˜8-mer) were investigated by using secondary ion mass spectrometry (SIMS) and APCI mass spectrometry (APCI-MS). Protonation and fragmentation mechanisms of MMA oligomers were clarified by using molecular orbital (MO) methods. MMA oligomers were synthesized in anionic polymerization, and the oligomers were fractionated into 3-mer˜8-mer using gel permeation chromatography (GPC). In SIMS of MMA oligomers (3-mer˜8-mer), [MH] +, [MH-CH 3OH] +, [MH-methyl formate] + and [MH-2CH 3OH-methyl formate] + appeared. The peak intensities of adduct ions [M+Li] +, [M+Na] + and [M+K] + increased with the increase of the polymerization degree. The optimized geometries and H +, Li +, Na + and K + affinities of MMA monomer (1-mer), dimer (2-mer), and trimer (3-mer) were calculated using the PM3 and ab initio MO methods. The calculated H +, Li +, Na + and K + affinities increased in order of 1-mer, 2-mer and 3-mer of MMA.

  20. On-site analysis of old deposited chemical warfare agents by combined use of ion mobility spectrometry and mass spectrometry

    SciTech Connect

    Stach, J.; Adler, J.; Brodacki, M.; Doering, H.R.; Flachowsky, J.; Loudon, A.

    1995-12-31

    The factory site of an old mustard gas plant was investigated with on-site analysis methods. Using ion mobility spectrometry and mass spectrometry a lot of degradation products of mustard gas could be detected. Sulfur mustard was found in one soil sample and in ceramic material of a bunker used for storage of the produced warfare agents. Concentrations of the mustard gas are in the sub ppb level. The results of ion mobility and mass spectrometry agreed in 95 % of the investigated samples.