Science.gov

Sample records for multi-channel high time

  1. A multi-channel high time resolution detector for high content imaging

    NASA Astrophysics Data System (ADS)

    Lapington, J. S.; Fraser, G. W.; Miller, G. M.; Ashton, T. J. R.; Jarron, P.; Despeisse, M.; Powolny, F.; Howorth, J.; Milnes, J.

    2009-10-01

    Medical imaging has long benefited from advances in photon counting detectors arising from space and particle physics. We describe a microchannel plate-based detector system for high content (multi-parametric) analysis, specifically designed to provide a step change in performance and throughput for measurements in imaged live cells and tissue for the 'omics'. The detector system integrates multi-channel, high time resolution, photon counting capability into a single miniaturized detector with integrated ASIC electronics, comprising a fast, low power amplifier discriminator and TDC for every channel of the discrete pixel electronic readout, and achieving a pixel density improvement of order two magnitudes compared with current comparable devices. The device combines high performance, easy reconfigurability, and economy within a compact footprint. We present simulations and preliminary measurements in the context of our ultimate goals of 20 ps time resolution with multi-channel parallel analysis (1024 channels).

  2. A high-throughput, multi-channel photon-counting detector with picosecond timing

    NASA Astrophysics Data System (ADS)

    Lapington, J. S.; Fraser, G. W.; Miller, G. M.; Ashton, T. J. R.; Jarron, P.; Despeisse, M.; Powolny, F.; Howorth, J.; Milnes, J.

    2009-06-01

    High-throughput photon counting with high time resolution is a niche application area where vacuum tubes can still outperform solid-state devices. Applications in the life sciences utilizing time-resolved spectroscopies, particularly in the growing field of proteomics, will benefit greatly from performance enhancements in event timing and detector throughput. The HiContent project is a collaboration between the University of Leicester Space Research Centre, the Microelectronics Group at CERN, Photek Ltd., and end-users at the Gray Cancer Institute and the University of Manchester. The goal is to develop a detector system specifically designed for optical proteomics, capable of high content (multi-parametric) analysis at high throughput. The HiContent detector system is being developed to exploit this niche market. It combines multi-channel, high time resolution photon counting in a single miniaturized detector system with integrated electronics. The combination of enabling technologies; small pore microchannel plate devices with very high time resolution, and high-speed multi-channel ASIC electronics developed for the LHC at CERN, provides the necessary building blocks for a high-throughput detector system with up to 1024 parallel counting channels and 20 ps time resolution. We describe the detector and electronic design, discuss the current status of the HiContent project and present the results from a 64-channel prototype system. In the absence of an operational detector, we present measurements of the electronics performance using a pulse generator to simulate detector events. Event timing results from the NINO high-speed front-end ASIC captured using a fast digital oscilloscope are compared with data taken with the proposed electronic configuration which uses the multi-channel HPTDC timing ASIC.

  3. Real-time system design environment for multi-channel high-speed data acquisition system and pattern recognition

    SciTech Connect

    Crosetto, Dario B.

    1999-06-17

    The Design Real-Time 2.0 software environment provides the user with a set of tools to create a real-time fully programmable system which can sustain a rate of several MHz from multi-channel inputs, can extend processing time in a pipeline stage and can provide a result within a few hundred ns. The tool set allows the user to (a) create applications of different sizes with different throughput and filtering algorithms; (b) select the processor speed, internal bus width, lookup tables, number of input and output result bits for each set of data received at each channel for each algorithm execution; (c) simulate a specific parallel-processing system for a given algorithm on different sets of data; (d) monitor the system in real time via an RS232 interface; (e) create a hardware component (FPGA or ASIC) by means of interfacing to the Electronic Design Automation (EDA) tools. The advantage of these tools is that of allowing simulation, before construction, of an entire programmable high-speed data acquisition and processing system, and selection of the processor speed, bus width and real-time algorithm which is most cost effective for a specific application where general-purpose processors fail in speed and performance. Benefits derived from the use of the novel architecture and cost comparisons with respect to similar designs are also provided.

  4. High transformer ratio of multi-channel dielectric wakefield structures

    NASA Astrophysics Data System (ADS)

    Shchelkunov, Sergey V.; Marshall, Thomas C.; Sotnikov, Gennadij V.; Hirshfield, Jay L.

    2016-09-01

    Dielectric wakefield (DWA) accelerator concepts are receiving attention on account of their promising performance, mechanical simplicity, and anticipated low cost. Interest in DWA physics directed toward an advanced high-gradient accelerator has been enhanced by a finding that some dielectrics can withstand very high fields (>1 GV/m) for the short times during the passage of charged bunches along dielectric-lined channels. In a two-channel structure, a drive bunch train propagates in a first channel, and in the second adjacent channel where a high gradient wakefield develops, a witness bunch is accelerated. Compared with single-channel DWA's, a two-beam accelerator delivers a high transformer ratio, and thereby reduces the number of drive beam sections needed to achieve a given final test beam energy. An overview of multi-channel DWA structures will be given, with an emphasis on two-channel structures, presenting their advantages and drawbacks, and potential impact on the field. Studies aimed to examine charging rate and charge distribution in a thin walled dielectric wakefield accelerator from a passing charge bunch and the physics of conductivity and discharge phenomena in dielectric materials useful for such accelerator applications are presented in a separate paper in the EAAC-2015 conference proceedings.

  5. A high speed direct digital frequency synthesizer based on multi-channel structure

    NASA Astrophysics Data System (ADS)

    Ling, Yuan; Qiang, Zhang; Yin, Shi

    2015-06-01

    This paper presents a direct digital frequency synthesizer (DDFS) for high speed application based on multi-channel structure. This DDFS has phase resolution of 32 bits and magnitude resolution of 12 bits. In order to ensure the high speed and high resolution at the same time, the multi-channel sampling technique is used and a 12 bits linear digital-to-analog converter is implemented. The chip is fabricated in TSMC 130 nm CMOS technology with active area of 0.89 × 0.98 mm2 and total power consumption of 300 mW at a single 1.2 V supply voltage. The maximum operating speed is up to 2.0 GHz at room temperature.

  6. Development of a Multi-Channel, High Frequency QRS Electrocardiograph

    NASA Technical Reports Server (NTRS)

    DePalma, Jude L.

    2003-01-01

    With the advent of the ISS era and the potential requirement for increased cardiovascular monitoring of crewmembers during extended EVAs, NASA flight surgeons would stand to benefit from an evolving technology that allows for a more rapid diagnosis of myocardial ischemia compared to standard electrocardiography. Similarly, during the astronaut selection process, NASA flight surgeons and other physicians would also stand to benefit from a completely noninvasive technology that, either at rest or during maximal exercise tests, is more sensitive than standard ECG in identifying the presence of ischemia. Perhaps most importantly, practicing cardiologists and emergency medicine physicians could greatly benefit from such a device as it could augment (or even replace) standard electrocardiography in settings where the rapid diagnosis of myocardial ischemia (or the lack thereof) is required for proper clinical decision-making. A multi-channel, high-frequency QRS electrocardiograph is currently under development in the Life Sciences Research Laboratories at JSC. Specifically the project consisted of writing software code, some of which contained specially-designed digital filters, which will be incorporated into an existing commercial software program that is already designed to collect, plot and analyze conventional 12-lead ECG signals on a desktop, portable or palm PC. The software will derive the high-frequency QRS signals, which will be analyzed (in numerous ways) and plotted alongside of the conventional ECG signals, giving the PC-viewing clinician advanced diagnostic information that has never been available previously in all 12 ECG leads simultaneously. After the hardware and software for the advanced digital ECG monitor have been fully integrated, plans are to use the monitor to begin clinical studies both on healthy subjects and on patients with known coronary artery disease in both the outpatient and hospital settings. The ultimate goal is to get the technology

  7. Multi-channel holographic birfurcative neural network system for real-time adaptive EOS data analysis

    NASA Technical Reports Server (NTRS)

    Liu, Hua-Kuang; Diep, J.; Huang, K.

    1991-01-01

    Viewgraphs on multi-channel holographic bifurcative neural network system for real-time adaptive Earth Observing System (EOS) data analysis are presented. The objective is to research and develop an optical bifurcating neuromorphic pattern recognition system for making optical data array comparisons and to evaluate the use of the system for EOS data classification, reduction, analysis, and other applications.

  8. Multi-channel data acquisition system with absolute time synchronization

    NASA Astrophysics Data System (ADS)

    Włodarczyk, Przemysław; Pustelny, Szymon; Budker, Dmitry; Lipiński, Marcin

    2014-11-01

    We present a low-cost, stand-alone global-time-synchronized data acquisition system. Our prototype allows recording up to four analog signals with a 16-bit resolution in variable ranges and a maximum sampling rate of 1000 S/s. The system simultaneously acquires readouts of external sensors e.g. magnetometer or thermometer. A complete data set, including a header containing timestamp, is stored on a Secure Digital (SD) card or transmitted to a computer using Universal Serial Bus (USB). The estimated time accuracy of the data acquisition is better than ±200 ns. The device is intended for use in a global network of optical magnetometers (the Global Network of Optical Magnetometers for Exotic physics - GNOME), which aims to search for signals heralding physics beyond the Standard Model, that can be generated by ordinary spin coupling to exotic particles or anomalous spin interactions.

  9. Continuous flow real-time PCR device using multi-channel fluorescence excitation and detection.

    PubMed

    Hatch, Andrew C; Ray, Tathagata; Lintecum, Kelly; Youngbull, Cody

    2014-02-01

    High throughput automation is greatly enhanced using techniques that employ conveyor belt strategies with un-interrupted streams of flow. We have developed a 'conveyor belt' analog for high throughput real-time quantitative Polymerase Chain Reaction (qPCR) using droplet emulsion technology. We developed a low power, portable device that employs LED and fiber optic fluorescence excitation in conjunction with a continuous flow thermal cycler to achieve multi-channel fluorescence detection for real-time fluorescence measurements. Continuously streaming fluid plugs or droplets pass through tubing wrapped around a two-temperature zone thermal block with each wrap of tubing fluorescently coupled to a 64-channel multi-anode PMT. This work demonstrates real-time qPCR of 0.1-10 μL droplets or fluid plugs over a range of 7 orders of magnitude concentration from 1 × 10(1) to 1 × 10(7). The real-time qPCR analysis allows dynamic range quantification as high as 1 × 10(7) copies per 10 μL reaction, with PCR efficiencies within the range of 90-110% based on serial dilution assays and a limit of detection of 10 copies per rxn. The combined functionality of continuous flow, low power thermal cycling, high throughput sample processing, and real-time qPCR improves the rates at which biological or environmental samples can be continuously sampled and analyzed. PMID:24297040

  10. Device for modular input high-speed multi-channel digitizing of electrical data

    DOEpatents

    VanDeusen, A.L.; Crist, C.E.

    1995-09-26

    A multi-channel high-speed digitizer module converts a plurality of analog signals to digital signals (digitizing) and stores the signals in a memory device. The analog input channels are digitized simultaneously at high speed with a relatively large number of on-board memory data points per channel. The module provides an automated calibration based upon a single voltage reference source. Low signal noise at such a high density and sample rate is accomplished by ensuring the A/D converters are clocked at the same point in the noise cycle each time so that synchronous noise sampling occurs. This sampling process, in conjunction with an automated calibration, yields signal noise levels well below the noise level present on the analog reference voltages. 1 fig.

  11. Device for modular input high-speed multi-channel digitizing of electrical data

    DOEpatents

    VanDeusen, Alan L.; Crist, Charles E.

    1995-09-26

    A multi-channel high-speed digitizer module converts a plurality of analog signals to digital signals (digitizing) and stores the signals in a memory device. The analog input channels are digitized simultaneously at high speed with a relatively large number of on-board memory data points per channel. The module provides an automated calibration based upon a single voltage reference source. Low signal noise at such a high density and sample rate is accomplished by ensuring the A/D converters are clocked at the same point in the noise cycle each time so that synchronous noise sampling occurs. This sampling process, in conjunction with an automated calibration, yields signal noise levels well below the noise level present on the analog reference voltages.

  12. Self-adaptive method for high frequency multi-channel analysis of surface wave method

    Technology Transfer Automated Retrieval System (TEKTRAN)

    When the high frequency multi-channel analysis of surface waves (MASW) method is conducted to explore soil properties in the vadose zone, existing rules for selecting the near offset and spread lengths cannot satisfy the requirements of planar dominant Rayleigh waves for all frequencies of interest ...

  13. B0 mapping with multi-channel RF coils at high field.

    PubMed

    Robinson, Simon; Jovicich, Jorge

    2011-10-01

    Mapping the static magnetic field via the phase evolution over gradient echo scans acquired at two or more echo times is an established method. A number of possibilities exist, however, for combining phase data from multi-channel coils, denoising and thresholding field maps for high field applications. Three methods for combining phase images when no body/volume coil is available are tested: (i) Hermitian product, (ii) phase-matching over channels, and (iii) a new approach based on calculating separate field maps for each channel. The separate channel method is shown to yield field maps with higher signal-to-noise ratio than the Hermitian product and phase-matching methods and fewer unwrapping errors at low signal-to-noise ratio. Separate channel combination also allows unreliable voxels to be identified via the standard deviation over channels, which is found to be the most effective means of denoising field maps. Tests were performed using multichannel coils with between 8 and 32 channels at 3 T, 4 T, and 7 T. For application in the correction of distortions in echo-planar images, a formulation is proposed for reducing the local gradient of field maps to eliminate signal pile-up or swapping artifacts. Field maps calculated using these techniques, implemented in a freely available MATLAB toolbox, provide the basis for an effective correction for echo-planar imaging distortions at high fields. PMID:21608027

  14. Photonic-assisted multi-channel compressive sampling based on effective time delay pattern.

    PubMed

    Liang, Yunhua; Chen, Minghua; Chen, Hongwei; Lei, Cheng; Li, Pengxiao; Xie, Shizhong

    2013-11-01

    In this paper, a photonic-assisted multi-channel compressive sampling scheme is proposed with one pseudo-random binary sequence (PRBS) source and Wavelength Division Multiplexing-based time delay. Meanwhile, the restricted isometry property of sensing matrix determined by the optimized time delay pattern is analyzed. In experiment, a four-channel photonic-assisted system with 5-GHz bandwidth was set up, where four-channel PRBS signals were generated by adding fiber-induced constant time delays to four-wavelength modulated PRBS signal, and a signal composed of twenty tones was recovered faithfully with four analog-to-digital converters (ADCs) with only 120-MHz-bandwidth. PMID:24216795

  15. The dynamic time-over-threshold method for multi-channel APD based gamma-ray detectors

    NASA Astrophysics Data System (ADS)

    Orita, T.; Shimazoe, K.; Takahashi, H.

    2015-03-01

    t- Recent advances in manufacturing technology have enabled the use of multi-channel pixelated detectors in gamma-ray imaging applications. When obtaining gamma-ray measurements, it is important to obtain pulse height information in order to avoid unnecessary events such as scattering. However, as the number of channels increases, more electronics are needed to process each channel's signal, and the corresponding increases in circuit size and power consumption can result in practical problems. The time-over-threshold (ToT) method, which has recently become popular in the medical field, is a signal processing technique that can effectively avoid such problems. However, ToT suffers from poor linearity and its dynamic range is limited. We therefore propose a new ToT technique called the dynamic time-over-threshold (dToT) method [4]. A new signal processing system using dToT and CR-RC shaping demonstrated much better linearity than that of a conventional ToT. Using a test circuit with a new Gd3Al2Ga3O12 (GAGG) scintillator and an avalanche photodiode, the pulse height spectra of 137Cs and 22Na sources were measured with high linearity. Based on these results, we designed a new application-specific integrated circuit (ASIC) for this multi-channel dToT system, measured the spectra of a 22Na source, and investigated the linearity of the system.

  16. Boresonic testing utilizing multi-channel C-scan imaging in real time

    SciTech Connect

    Porter, J.P.; Morrison, J.W.

    1994-12-31

    Boreside nondestructive inspection techniques capable of detecting small, yet potentially dangerous flaws in turbine/generator rotors have been developed and utilized for several years. Test methods have ranged from simple hand scanning to very complex computer driven data acquisition systems. Under the direction of Northeast Inspection Services, Inc., an automated computer controlled ultrasonic recording apparatus (ACCURA) system has been developed, evaluated by EPRI, and utilized in the field to perform boresonic tests. The system provides real time multi-channel C-scan imaging of ultrasonic reflectors. Numerical data table files are stored in ASCII format for use in engineering analyses for flaw evaluation and lifetime prediction. A number of applications ranging from turbine rotor tests for detection of near bore indications to peripheral circumferential crack detection in generator rotors are described to illustrate the versatility of the system. The sensitivity and detection reliability of the system are also discussed.

  17. Low-cost high performance distributed data storage for multi-channel observations

    NASA Astrophysics Data System (ADS)

    Liu, Ying-bo; Wang, Feng; Deng, Hui; Ji, Kai-fan; Dai, Wei; Wei, Shou-lin; Liang, Bo; Zhang, Xiao-li

    2015-10-01

    The New Vacuum Solar Telescope (NVST) is a 1-m solar telescope that aims to observe the fine structures in both the photosphere and the chromosphere of the Sun. The observational data acquired simultaneously from one channel for the chromosphere and two channels for the photosphere bring great challenges to the data storage of NVST. The multi-channel instruments of NVST, including scientific cameras and multi-band spectrometers, generate at least 3 terabytes data per day and require high access performance while storing massive short-exposure images. It is worth studying and implementing a storage system for NVST which would balance the data availability, access performance and the cost of development. In this paper, we build a distributed data storage system (DDSS) for NVST and then deeply evaluate the availability of real-time data storage on a distributed computing environment. The experimental results show that two factors, i.e., the number of concurrent read/write and the file size, are critically important for improving the performance of data access on a distributed environment. Referring to these two factors, three strategies for storing FITS files are presented and implemented to ensure the access performance of the DDSS under conditions of multi-host write and read simultaneously. The real applications of the DDSS proves that the system is capable of meeting the requirements of NVST real-time high performance observational data storage. Our study on the DDSS is the first attempt for modern astronomical telescope systems to store real-time observational data on a low-cost distributed system. The research results and corresponding techniques of the DDSS provide a new option for designing real-time massive astronomical data storage system and will be a reference for future astronomical data storage.

  18. High Speed, Multi-Channel, Thermal Instrument Development in Support of HyspIRI-TIR

    NASA Technical Reports Server (NTRS)

    Johnson, William R.; Hook, Simon J.; Foote, Marc; Eng, Bjorn T.; Jau, Bruno

    2011-01-01

    The Jet Propulsion Laboratory is currently developing an end-to-end instrument which will provide a proof of concept prototype vehicle for a high data rate, multi-channel, thermal instrument in support of the Hyperspectral Infrared Imager (HyspIRI)-Thermal Infrared (TIR) space mission. HyspIRI mission was recommended by the National Research Council Decadal Survey (DS). The HyspIRI mission includes a visible shortwave infrared (SWIR) pushboom spectrometer and a multispectral whiskbroom thermal infrared (TIR) imager. The prototype testbed instrument addressed in this effort will only support the TIR. Data from the HyspIRI mission will be used to address key science questions related to the Solid Earth and Carbon Cycle and Ecosystems focus areas of the NASA Science Mission Directorate. Current designs for the HyspIRI-TIR space borne imager utilize eight spectral bands delineated with filters. The system will have 60m ground resolution, 200mK NEDT, 0.5C absolute temperature resolution with a 5-day repeat from LEO orbit. The prototype instrument will use mercury cadmium telluride (MCT) technology at the focal plane array in time delay integration mode. A custom read out integrated circuit (ROIC) will provide the high speed readout hence high data rates needed for the 5 day repeat. The current HyspIRI requirements dictate a ground knowledge measurement of 30m, so the prototype instrument will tackle this problem with a newly developed interferometeric metrology system. This will provide an absolute measurement of the scanning mirror to an order of magnitude better than conventional optical encoders. This will minimize the reliance on ground control points hence minimizing postprocessing (e.g. geo-rectification computations).

  19. Development of a multi-channel time-domain fluorescence mammograph

    NASA Astrophysics Data System (ADS)

    Hagen, A.; Steinkellner, O.; Grosenick, D.; Möller, M.; Ziegler, R.; Nielsen, T.; Lauritsen, K.; Macdonald, R.; Rinneberg, H.

    2007-02-01

    We developed an eight-channel scanning time-domain fluorescence mammograph capable of imaging the distribution of a non-specific fluorescent contrast agent in the female breast, besides imaging intrinsic absorption and scattering properties of healthy breast tissue and tumors. The apparatus is based on the PTB multi-channel laser pulse mammograph, originally designed for measurements of absorption and scattering coefficients at four selected wavelengths (λ = 652 nm, 684 nm, 797nm, and 830 nm). It was upgraded for time-resolved detection of fluorescence, excited at 735 nm by a ps diode laser with 10 mW output power and detected at wavelengths λ >= 780 nm. Cooled PMTs with GaAs photocathodes are used to detect laser and fluorescence photons at five positions in transmission and three positions in reflection. Measurements are performed with the breast being slightly compressed between two parallel glass plates. The transmitting and receiving fiber bundles are scanned synchronously over the breast in steps of typically 2.5 mm. At each scan position, distributions of times of flight of laser photons are measured by time-correlated single photon counting at eight detector positions, followed by measurements of distributions of times of arrival of fluorescence photons. The performance of the fluorescence mammograph was investigated by using breast-like phantoms with a fluorescent inhomogeneity with dye enrichment varying between 2:1 and 10:1 over background values.

  20. High-throughput hyperpolarized 13C metabolic investigations using a multi-channel acquisition system

    NASA Astrophysics Data System (ADS)

    Lee, Jaehyuk; Ramirez, Marc S.; Walker, Christopher M.; Chen, Yunyun; Yi, Stacey; Sandulache, Vlad C.; Lai, Stephen Y.; Bankson, James A.

    2015-11-01

    Magnetic resonance imaging and spectroscopy of hyperpolarized (HP) compounds such as [1-13C]-pyruvate have shown tremendous potential for offering new insight into disease and response to therapy. New applications of this technology in clinical research and care will require extensive validation in cells and animal models, a process that may be limited by the high cost and modest throughput associated with dynamic nuclear polarization. Relatively wide spectral separation between [1-13C]-pyruvate and its chemical endpoints in vivo are conducive to simultaneous multi-sample measurements, even in the presence of a suboptimal global shim. Multi-channel acquisitions could conserve costs and accelerate experiments by allowing acquisition from multiple independent samples following a single dissolution. Unfortunately, many existing preclinical MRI systems are equipped with only a single channel for broadband acquisitions. In this work, we examine the feasibility of this concept using a broadband multi-channel digital receiver extension and detector arrays that allow concurrent measurement of dynamic spectroscopic data from ex vivo enzyme phantoms, in vitro anaplastic thyroid carcinoma cells, and in vivo in tumor-bearing mice. Throughput and the cost of consumables were improved by up to a factor of four. These preliminary results demonstrate the potential for efficient multi-sample studies employing hyperpolarized agents.

  1. Image reconstruction of multi-channel photoacoustic and laser-ultrasound data using reverse time migration

    NASA Astrophysics Data System (ADS)

    Johnson, Jami L.; Shragge, Jeffrey; van Wijk, Kasper

    2015-03-01

    We propose a new reconstruction algorithm for photoacoustic and laser-ultrasound imaging based on reverse time migration (RTM), a time reversal imaging algorithm originally developed for exploration seismology. RTM inherently handles strong velocity heterogeneity and complex propagation paths. A successful RTM analysis with appropriate handling of boundary conditions results in enhanced signal-to-noise, accurately located structures, and minimal artifacts. A laser-ultrasound experiment begins with a source wave field generated at the surface that propagates through the sample. Acoustic scatterers in the propagation path give rise to a scattered wave field, which travels to the surface and is recorded by acoustic detectors. To reconstruct the laser-ultrasound image, a synthetic source function is forward propagated and cross-correlated with the time-reversed and back-propagated recorded (scattered) wave field to image the scatterers at the correct location. Conversely, photoacoustic waves are generated by chromophores within the sample and propagate "one-way" to the detection surface. We utilize the velocity model validated by the laser-ultrasound reconstruction to accurately reconstruct the photoacoustic image with RTM. This approach is first validated with simulations, where inclusions behave both as a photoacoustic source and an acoustic scatterer. Subsequently, we demonstrate the capabilities of RTM with tissue phantom experiments using an all-optical, multi-channel acquisition geometry.

  2. Time-varying bispectral analysis of visually evoked multi-channel EEG

    NASA Astrophysics Data System (ADS)

    Chandran, Vinod

    2012-12-01

    Theoretical foundations of higher order spectral analysis are revisited to examine the use of time-varying bicoherence on non-stationary signals using a classical short-time Fourier approach. A methodology is developed to apply this to evoked EEG responses where a stimulus-locked time reference is available. Short-time windowed ensembles of the response at the same offset from the reference are considered as ergodic cyclostationary processes within a non-stationary random process. Bicoherence can be estimated reliably with known levels at which it is significantly different from zero and can be tracked as a function of offset from the stimulus. When this methodology is applied to multi-channel EEG, it is possible to obtain information about phase synchronization at different regions of the brain as the neural response develops. The methodology is applied to analyze evoked EEG response to flash visual stimulii to the left and right eye separately. The EEG electrode array is segmented based on bicoherence evolution with time using the mean absolute difference as a measure of dissimilarity. Segment maps confirm the importance of the occipital region in visual processing and demonstrate a link between the frontal and occipital regions during the response. Maps are constructed using bicoherence at bifrequencies that include the alpha band frequency of 8Hz as well as 4 and 20Hz. Differences are observed between responses from the left eye and the right eye, and also between subjects. The methodology shows potential as a neurological functional imaging technique that can be further developed for diagnosis and monitoring using scalp EEG which is less invasive and less expensive than magnetic resonance imaging.

  3. Modelling Temporal Stability of EPI Time Series Using Magnitude Images Acquired with Multi-Channel Receiver Coils

    PubMed Central

    Hutton, Chloe; Balteau, Evelyne; Lutti, Antoine; Josephs, Oliver; Weiskopf, Nikolaus

    2012-01-01

    In 2001, Krueger and Glover introduced a model describing the temporal SNR (tSNR) of an EPI time series as a function of image SNR (SNR0). This model has been used to study physiological noise in fMRI, to optimize fMRI acquisition parameters, and to estimate maximum attainable tSNR for a given set of MR image acquisition and processing parameters. In its current form, this noise model requires the accurate estimation of image SNR. For multi-channel receiver coils, this is not straightforward because it requires export and reconstruction of large amounts of k-space raw data and detailed, custom-made image reconstruction methods. Here we present a simple extension to the model that allows characterization of the temporal noise properties of EPI time series acquired with multi-channel receiver coils, and reconstructed with standard root-sum-of-squares combination, without the need for raw data or custom-made image reconstruction. The proposed extended model includes an additional parameter κ which reflects the impact of noise correlations between receiver channels on the data and scales an apparent image SNR (SNR′0) measured directly from root-sum-of-squares reconstructed magnitude images so that κ = SNR′0/SNR0 (under the condition of SNR0>50 and number of channels ≤32). Using Monte Carlo simulations we show that the extended model parameters can be estimated with high accuracy. The estimation of the parameter κ was validated using an independent measure of the actual SNR0 for non-accelerated phantom data acquired at 3T with a 32-channel receiver coil. We also demonstrate that compared to the original model the extended model results in an improved fit to human task-free non-accelerated fMRI data acquired at 7T with a 24-channel receiver coil. In particular, the extended model improves the prediction of low to medium tSNR values and so can play an important role in the optimization of high-resolution fMRI experiments at lower SNR levels. PMID:23284874

  4. A sophisticated, multi-channel data acquisition and processing system for high frequency noise research

    NASA Technical Reports Server (NTRS)

    Hall, David G.; Bridges, James

    1992-01-01

    A sophisticated, multi-channel computerized data acquisition and processing system was developed at the NASA LeRC for use in noise experiments. This technology, which is available for transfer to industry, provides a convenient, cost-effective alternative to analog tape recording for high frequency acoustic measurements. This system provides 32-channel acquisition of microphone signals with an analysis bandwidth up to 100 kHz per channel. Cost was minimized through the use of off-the-shelf components. Requirements to allow for future expansion were met by choosing equipment which adheres to established industry standards for hardware and software. Data processing capabilities include narrow band and 1/3 octave spectral analysis, compensation for microphone frequency response/directivity, and correction of acoustic data to standard day conditions. The system was used successfully in a major wind tunnel test program at NASA LeRC to acquire and analyze jet noise data in support of the High Speed Civil Transport (HSCT) program.

  5. Silicon Photomultiplier-Based Multi-Channel Gamma Ray Detector Using the Dynamic Time-Over-Threshold Method

    NASA Astrophysics Data System (ADS)

    Nakamura, Y.; Shimazoe, K.; Takahashi, H.

    2016-02-01

    Silicon photomultipliers (SiPMs), which are a relatively new type of photon detector, have received more attention in the fields of nuclear medicine and high-energy physics because of their compactness and high gain up to 106. In this work, a SiPM-based multi-channel gamma ray detector with individual read out based on the dynamic time-over-threshold (dToT) method is implemented and demonstrated as an elemental material for large-area gamma ray imager applications. The detector consists of 64 channels of KETEK SiPM PM6660 (6 × 6 mm2 containing 10,000 micro-cells of 60 × 60 μm2) coupled to an 8 × 8 array of high-energy resolution Gd3(Al,Ga)5O12(Ce) (HR-GAGG) crystals (10 × 10 × 10 mm3) segmented by a 1 mm thick BaSO4 reflector. To produce a digital pulse containing linear energy information, the dToT-based read-out circuit consists of a CR-RC shaping amplifier (2.2 μs) and comparator with a feedback component. By modelling the pulse of the SiPM, the light output, and the CR-RC shaping amplifier, the integral-non-linearity (INL) was numerically calculated in terms of the delay time and the time constant of dynamic threshold movement. The experimental results of the averaged INL and energy resolution were 5.8±1.6% and the full-width-at-half-maximum (FWHM) of 7.4±0.9% at 662 keV, respectively. The 64-channel single-mode detector module was successfully implemented, demonstrating potential for its use as an elemental material for large-area gamma ray imaging applications.

  6. Development of the Physical Structure of a Multi-Channel GNSS Signal Detector for Autonomous Coordination and Time Support of Artificial Earth Satellites

    NASA Astrophysics Data System (ADS)

    Shkol'nyi, V. N.; Suntsov, S. B.; Karaban, V. M.; Dmitriev, V. D.; Sheerman, F. I.

    2015-11-01

    Physical structure of a multi-channel detector of signals of global navigation satellite systems for autonomous coordination and time support of spacecrafts independent from the terrestrial infrastructure is analyzed. The parameters of multi-channel detector components are determined by mathematical modeling to achieve worldclass tactical and technical specifications. Technologies based on domestic 0.15 μm GaAs pHEMT (Closed JSC "Mikran," Tomsk) and 0.18 μm SiGe BiCMOS (JSC Research Institute of Molecular Electronics and "Mikron" Plant, Zelenograd) are taken for subsequent practical implementation in monolithic chip components of a navigation detector.

  7. RF/microwave system high-fidelity modeling and simulation: application to airborne multi-channel receiver system for angle of arrival estimation

    NASA Astrophysics Data System (ADS)

    Wu, Chen; Rajan, Sreeraman; Young, Anne; O'Regan, Christina

    2014-06-01

    In this paper, a high-fidelity RF modeling and simulation framework is demonstrated to model an airborne multi-channel receiver system that is used to estimate the angle of arrival (AoA) of received signals from a stationary emitter. The framework is based on System Tool Kit (STK®), Matlab and SystemVue®. The SystemVue-based multi-channel receiver estimates the AoA of incoming signals using adjacent channel amplitude and phase comparisons, and it estimates the Doppler frequency shift of the aircraft by processing the transmitted and received signals. The estimated AoA and Doppler frequency are compared with the ground-truth data provided by STK to validate the efficacy of the modeling process. Unlike other current RF electronic warfare simulation frameworks, the received signal described herein is formed using the received power, the propagation delay and the transmitted waveform, and does not require information such as Doppler frequency shift or radial velocity of the moving platform from the scenario; hence, the simulation is more computationally efficient. In addition, to further reduce the overall modeling and simulation time, since the high-fidelity model computation is costly, the high-fidelity electronic system model is evoked only when the received power is higher than a predetermined threshold.

  8. High repetition rate multi-channel source of high-power rf-modulated pulses

    NASA Astrophysics Data System (ADS)

    Ulmaskulov, M. R.; Pedos, M. S.; Rukin, S. N.; Sharypov, K. A.; Shpak, V. G.; Shunailov, S. A.; Yalandin, M. I.; Romanchenko, I. V.; Rostov, V. V.

    2015-07-01

    This paper presents the results of testing a high voltage pulse generator based on parallel gyromagnetic nonlinear transmission lines filled with saturable ferrite. The generator is capable of producing almost identical stable rf-modulated nanosecond high voltage pulses in each of the two, or four, parallel output channels. The output voltage amplitude in each channel can reach -285 or -180 kV, respectively, with a rf modulation depth of up to 60%. Drive pulses were produced as the packets of duration 1-5 s at a pulse repetition frequency of 800 Hz using a driver equipped with all-solid-state switches. Splitting the driver pulse provided electric field strengths in the channels which were below the breakdown field strength of the transmission lines. As a result, the use of nonlinear transmission lines of reduced diameter made it possible to increase the center frequency of the excited rf oscillations to ˜2 GHz.

  9. Multi-channel time-reversal receivers for multi and 1-bit implementations

    DOEpatents

    Candy, James V.; Chambers, David H.; Guidry, Brian L.; Poggio, Andrew J.; Robbins, Christopher L.

    2008-12-09

    A communication system for transmitting a signal through a channel medium comprising digitizing the signal, time-reversing the digitized signal, and transmitting the signal through the channel medium. In one embodiment a transmitter is adapted to transmit the signal, a multiplicity of receivers are adapted to receive the signal, a digitizer digitizes the signal, and a time-reversal signal processor is adapted to time-reverse the digitized signal. An embodiment of the present invention includes multi bit implementations. Another embodiment of the present invention includes 1-bit implementations. Another embodiment of the present invention includes a multiplicity of receivers used in the step of transmitting the signal through the channel medium.

  10. Delay Times From Clustered Multi-Channel Cross Correlation and Simulated Annealing

    NASA Astrophysics Data System (ADS)

    Creager, K. C.; Sambridge, M. S.

    2004-12-01

    Several techniques exist to estimate relative delay times of seismic phases based on the assumption that the waveforms observed at several stations can be expressed as a common waveform that has been time shifted and distorted by random uncorrelated noise. We explore the more general problem of estimating the relative delay times for regional or even global distributions of seismometers in cases where waveforms vary systematically across the array. The estimation of relative delay times is formulated as a global optimization of the weighted sum of squares of cross correlations of each seismogram pair evaluated at the corresponding difference in their relative delay times. As there are many local minima in this penalty function, a simulated annealing algorithm is used to obtain a solution. The weights depend strongly on the separation distance among seismogram pairs as well as a measure of the similarity of waveforms. Thus, seismograph pairs that are physically close to each other and have similar waveforms are expected to be well aligned while those with dissimilar waveforms or large separation distances are severely down-weighted and thus need not be well aligned. As a result noisy seismograms, which are not similar to other seismograms, are down-weighted so they do not adversely effect the relative delay times of other seismograms. Finally, natural clusters of seismograms are determined from the weight matrix. Examples of aligning a few hundred P and PKP waveforms from a broadband global array and from a mixed broadband and short-period continental-scale array will be shown. While this method has applications in many situations, it may be especially useful for arrays such as the EarthScope Bigfoot Array.

  11. Multi-channel seismic reflection database for the northern Gulf of California, a highly-sedimented oblique rift

    NASA Astrophysics Data System (ADS)

    Steckler, M. S.; Haxby, W.; Persaud, P.; Stock, J.; Martín-Barajas, A.; Diebold, J.; Gonzalez-Fernandez, A.; Mountain, G. S.

    2003-04-01

    A multi-channel seismic reflection database has been developed to give access to high-resolution MCS data collected in the northern Gulf of California in May-June 1999. This data set consists of 3500 km of high-resolution MCS data acquired by the LDEO portable 48-channel MCS system using a 600-m streamer, a 1-ms sampling interval, and CDP spacing of 6.25/12.5 m on board the B/O Ulloa, the 28-m research vessel of CICESE. The resulting images have vertical resolution on the scale of meters to depths of up to 2 km below the seafloor. In addition, 48 sonobuoys recorded to 7 sec TWTT provided refraction velocities to greater depths. The northern Gulf of California is a transitional region between the oceanic ridge transform system of the central and southern Gulf and the continental San Andreas fault system of southern California. This data images the active deformation associated with the plate boundary zone in the northern Gulf of California. Multiple parallel rifts are simultaneously active in this wide complex zone of regional extension overprinted by shearing and a high sediment influx. The public-access database makes the cruise results, which is in a US MARGINS Program focus area, available to the broader geoscience community. The database includes navigation, final stacks and images for 80 seismic lines and 48 sonobuoys. The database may be accessed with MapApp, a downloadable Java application. Java applets offer many advantages over static or scripted web pages; they permit dynamic local interaction with data sets and limit time-consuming interaction with a remote server. MapApp displays the seismic lines on a map, and provides a viewer for inspecting images of the lines. Users may select a line from a list, or by clicking on the map. Once a line is selected, a user may load the image into the viewer, or download navigation, image or SEG-Y files. The viewer includes capability to zoom in and out, scroll, stretch or shrink horizontally, reverse direction, and

  12. Taipei's Use of a Multi-Channel Mass Risk Communication Program to Rapidly Reverse an Epidemic of Highly Communicable Disease

    PubMed Central

    Yen, Muh-Yong; Wu, Tsung-Shu Joseph; Chiu, Allen Wen-Hsiang; Wong, Wing-Wai; Wang, Po-En; Chan, Ta-Chien; King, Chwan-Chuen

    2009-01-01

    Background In September 2007, an outbreak of acute hemorrhagic conjunctivitis (AHC) occurred in Keelung City and spread to Taipei City. In response to the epidemic, a new crisis management program was implemented and tested in Taipei. Methodology and Principal Findings Having noticed that transmission surged on weekends during the Keelung epidemic, Taipei City launched a multi-channel mass risk communications program that included short message service (SMS) messages sent directly to approximately 2.2 million Taipei residents on Friday, October 12th, 2007. The public was told to keep symptomatic students from schools and was provided guidelines for preventing the spread of the disease at home. Epidemiological characteristics of Taipei's outbreak were analyzed from 461 sampled AHC cases. Median time from exposure to onset of the disease was 1 day. This was significantly shorter for cases occurring in family clusters than in class clusters (mean±SD: 2.6±3.2 vs. 4.39±4.82 days, p = 0.03), as well as for cases occurring in larger family clusters as opposed to smaller ones (1.2±1.7 days vs. 3.9±4.0 days, p<0.01). Taipei's program had a significant impact on patient compliance. Home confinement of symptomatic children increased from 10% to 60% (p<0.05) and helped curb the spread of AHC. Taipei experienced a rapid decrease in AHC cases between the Friday of the SMS announcement and the following Monday, October 15, (0.70% vs. 0.36%). By October 26, AHC cases reduced to 0.01%. The success of this risk communication program in Taipei (as compared to Keelung) is further reflected through rapid improvements in three epidemic indicators: (1) significantly lower crude attack rates (1.95% vs. 14.92%, p<0.001), (2) a short epidemic period of AHC (13 vs. 34 days), and (3) a quick drop in risk level (1∼2 weeks) in Taipei districts that border Keelung (the original domestic epicenter). Conclusions and Significance The timely launch of this systematic, communication

  13. Investigation of verbal and visual working memory by multi-channel time-resolved functional near-infrared spectroscopy

    NASA Astrophysics Data System (ADS)

    Contini, D.; Caffini, M.; Re, R.; Zucchelli, L.; Spinelli, L.; Basso Moro, S.; Bisconti, S.; Ferrari, M.; Quaresima, V.; Cutini, S.; Torricelli, A.

    2013-03-01

    Working memory (WM) is fundamental for a number of cognitive processes, such as comprehension, reasoning and learning. WM allows the short-term maintenance and manipulation of the information selected by attentional processes. The goal of this study was to examine by time-resolved fNIRS neural correlates of the verbal and visual WM during forward and backward digit span (DF and DB, respectively) tasks, and symbol span (SS) task. A neural dissociation was hypothesised between the maintenance and manipulation processes. In particular, a dorsolateral/ventrolateral prefrontal cortex (DLPFC/VLPFC) recruitment was expected during the DB task, whilst a lateralised involvement of Brodmann Area (BA) 10 was expected during the execution of the DF task. Thirteen subjects were monitored by a multi-channel, dual-wavelength (690 and 829 nm) time-resolved fNIRS system during 3 minutes long DF and DB tasks and 4 minutes long SS task. The participants' mean memory span was calculated for each task: DF: 6.46+/-1.05 digits; DB: 5.62+/-1.26 digits; SS: 4.69+/-1.32 symbols. No correlation was found between the span level and the heart rate data (measured by pulse oximeter). As expected, DB elicited a broad activated area, in the bilateral VLPFC and the right DLPFC, whereas a more localised activation was observed over the right hemisphere during either DF (BA 10) or SS (BA 10 and 44). The robust involvement of the DLPFC during DB, compared to DF, is compatible with previous findings and with the key role of the central executive subserving in manipulating processes.

  14. High-speed, multi-channel detector readout electronics for fast radiation detectors

    SciTech Connect

    Hennig, Wolfgang

    2012-06-22

    In this project, we are developing a high speed digital spectrometer that a) captures detector waveforms at rates up to 500 MSPS b) has upgraded event data acquisition with additional data buffers for zero dead time operation c) moves energy calculations to the FPGA to increase spectrometer throughput in fast scintillator applications d) uses a streamlined architecture and high speed data interface for even faster readout to the host PC These features are in addition to the standard functions in our existing spectrometers such as digitization, programmable trigger and energy filters, pileup inspection, data acquisition with energy and time stamps, MCA histograms, and run statistics. In Phase I, we upgraded one of our existing spectrometer designs to demonstrate the key principle of fast waveform capture using a 500 MSPS, 12 bit ADC and a Xilinx Virtex-4 FPGA. This upgraded spectrometer, named P500, performed well in initial tests of energy resolution, pulse shape analysis, and timing measurements, thus achieving item (a) above. In Phase II, we are revising the P500 to build a commercial prototype with the improvements listed in items (b)-(d). As described in the previous report, two devices were built to pursue this goal, named the Pixie-500 and the Pixie-500 Express. The Pixie-500 has only minor improvements from the Phase I prototype and is intended as an early commercial product (its production and part of its development were funded outside the SBIR). It also allows testing of the ADC performance in real applications.The Pixie-500 Express (or Pixie-500e) includes all of the improvements (b)-(d). At the end of Phase II of the project, we have tested and debugged the hardware, firmware and software of the Pixie-500 Express prototype boards delivered 12/3/2010. This proved substantially more complex than anticipated. At the time of writing, all hardware bugs have been fixed, the PCI Express interface is working, the SDRAM has been successfully tested and the SHARC

  15. A Multi-Channel Method for Retrieving Surface Temperature for High-Emissivity Surfaces from Hyperspectral Thermal Infrared Images.

    PubMed

    Zhong, Xinke; Labed, Jelila; Zhou, Guoqing; Shao, Kun; Li, Zhao-Liang

    2015-01-01

    The surface temperature (ST) of high-emissivity surfaces is an important parameter in climate systems. The empirical methods for retrieving ST for high-emissivity surfaces from hyperspectral thermal infrared (HypTIR) images require spectrally continuous channel data. This paper aims to develop a multi-channel method for retrieving ST for high-emissivity surfaces from space-borne HypTIR data. With an assumption of land surface emissivity (LSE) of 1, ST is proposed as a function of 10 brightness temperatures measured at the top of atmosphere by a radiometer having a spectral interval of 800-1200 cm(-1) and a spectral sampling frequency of 0.25 cm(-1). We have analyzed the sensitivity of the proposed method to spectral sampling frequency and instrumental noise, and evaluated the proposed method using satellite data. The results indicated that the parameters in the developed function are dependent on the spectral sampling frequency and that ST of high-emissivity surfaces can be accurately retrieved by the proposed method if appropriate values are used for each spectral sampling frequency. The results also showed that the accuracy of the retrieved ST is of the order of magnitude of the instrumental noise and that the root mean square error (RMSE) of the ST retrieved from satellite data is 0.43 K in comparison with the AVHRR SST product. PMID:26061199

  16. A Multi-Channel Method for Retrieving Surface Temperature for High-Emissivity Surfaces from Hyperspectral Thermal Infrared Images

    PubMed Central

    Zhong, Xinke; Labed, Jelila; Zhou, Guoqing; Shao, Kun; Li, Zhao-Liang

    2015-01-01

    The surface temperature (ST) of high-emissivity surfaces is an important parameter in climate systems. The empirical methods for retrieving ST for high-emissivity surfaces from hyperspectral thermal infrared (HypTIR) images require spectrally continuous channel data. This paper aims to develop a multi-channel method for retrieving ST for high-emissivity surfaces from space-borne HypTIR data. With an assumption of land surface emissivity (LSE) of 1, ST is proposed as a function of 10 brightness temperatures measured at the top of atmosphere by a radiometer having a spectral interval of 800–1200 cm−1 and a spectral sampling frequency of 0.25 cm−1. We have analyzed the sensitivity of the proposed method to spectral sampling frequency and instrumental noise, and evaluated the proposed method using satellite data. The results indicated that the parameters in the developed function are dependent on the spectral sampling frequency and that ST of high-emissivity surfaces can be accurately retrieved by the proposed method if appropriate values are used for each spectral sampling frequency. The results also showed that the accuracy of the retrieved ST is of the order of magnitude of the instrumental noise and that the root mean square error (RMSE) of the ST retrieved from satellite data is 0.43 K in comparison with the AVHRR SST product. PMID:26061199

  17. Highly Sensitive Multi-Channel IDC Sensor Array for Low Concentration Taste Detection

    PubMed Central

    Khan, Md. Rajibur Rahaman; Kang, Shin-Won

    2015-01-01

    In this study, we designed and developed an interdigitated capacitor (IDC)-based taste sensor array to detect different taste substances. The designed taste sensing array has four IDC sensing elements. The four IDC taste sensing elements of the array are fabricated by incorporating four different types of lipids into the polymer, dioctyl phenylphosphonate (DOPP) and tetrahydrofuran (THF) to make the respective dielectric materials that are individually placed onto an interdigitated electrode (IDE) via spin coating. When the dielectric material of an IDC sensing element comes into contact with a taste substance, its dielectric properties change with the capacitance of the IDC sensing element; this, in turn, changes the voltage across the IDC, as well as the output voltage of each channel of the system. In order to assess the effectiveness of the sensing system, four taste substances, namely sourness (HCl), saltiness (NaCl), sweetness (glucose) and bitterness (quinine-HCl), were tested. The IDC taste sensor array had rapid response and recovery times of about 12.9 s and 13.39 s, respectively, with highly stable response properties. The response property of the proposed IDC taste sensor array was linear, and its correlation coefficient R2 was about 0.9958 over the dynamic range of the taste sensor array as the taste substance concentration was varied from 1 μM to 1 M. The proposed IDC taste sensor array has several other advantages, such as real-time monitoring capabilities, high sensitivity 45.78 mV/decade, good reproducibility with a standard deviation of about 0.029 and compactness, and the circuitry is based on readily available and inexpensive electronic components. The proposed IDC taste sensor array was compared with the potentiometric taste sensor with respect to sensitivity, dynamic range width, linearity and response time. We found that the proposed IDC sensor array has better performance. Finally, principal component analysis (PCA) was applied to

  18. High speed, multi-channel, user programmable digital data acquisition system.

    SciTech Connect

    Sabourov, Konstantin; Hennig, Wolfgang; Walby, Mark

    2013-11-18

    As applications for radiation detection become more demanding, and in turn improvements are made in the technology of radiation detection, there is a need for high speed digital detector readout electronics matching these improvements. Specifically, full control over the on-line processing resources of modern digital electronics is desirable so that researchers can develop custom algorithms for special applications.In the proposed effort, the 500 MHz digital readout electronics previously developed by our company will be redesigned to allow user access to the on-line processing resources. In Phase I, the division of online processing into vendor and user firmware sections has been studied on existing hardware. In Phase II, the hardware will be upgraded to better facilitate the division, and the firmware will be restructured into a robust vendor logic block (providing standard functions such as host I/O, on-board memory I/O, energy computation, MCA spectra, timestamps, waveform capture, run statistics, and triggering and timing) and a user logic block for custom algorithms (with templates and examples for frequently used functions). Investigating several options to divide online processing, it was determined that the most promising approach is to “partition” a single FPGA integrated circuit into a vendor and user section, which is supported in newer devices. The analog front end of the existing electronics proved suitable for most applications, in particular high rate measurements with germanium detectors. The design architecture for new electronics was developed, combining one of the new FPGA device with the analog front end.

  19. High speed multi-channel optical sampling technique for analog-to-digital converters

    NASA Astrophysics Data System (ADS)

    Noman, Mohammad; Donkor, Eric; Hayduk, Michael J.; Bussjager, Rebecca J.

    2005-05-01

    We describe the design and implementation of an eight channel optical sampling technique for analog-to-digital (A/D) converters. A single mode-locked laser source with a pulse reprtition rate of 250 MHz is used to generate eight highly synchronized smapling clocks each running at 500 MHz. The basic sampling circuit consistes of a reversed-biased photodiode which operates as a very fast optoelectronic switch. Actuating the photodiode ON and OFF with mode-locked laser pulses produce sampled RF signals. In the implementation of this A/D architecture, the optical clocks are delayed relative to each other using fixed passive delay lines. The time-shifted clock signals allow for sampling different phases of the input RF signal resulting in an aggregate sampling rate of 4 Gigasamples/sec (GSPS). We shall show the optical clock setup necessary in order to achieve a 4 BSPS rate. We shall also present sampling results for input RF signals with frequencies ranging from 10 to 500. Interleaving of the sampled RF output from different sampling channels will also be demonstrated.

  20. Multi-channel analysis of surface waves MASW of models with high shear-wave velocity contrast

    USGS Publications Warehouse

    Ivanov, J.; Miller, R.D.; Peterie, S.; Zeng, C.; Xia, J.; Schwenk, T.

    2011-01-01

    We use the multi-channel analysis of surface waves MASW method to analyze synthetic seismic data calculated using models with high shear-wave velocity Vs contrast. The MASW dispersion-curve images of the Rayleigh wave are obtained using various sets of source-offset and spread-size configurations from the synthetic seismic data and compared with the theoretically calculated fundamental- and higher-mode dispersion-curves. Such tests showed that most of the dispersion-curve images are dominated by higher-mode energy at the low frequencies, especially when analyzing data from long receiver offsets and thus significantly divert from numerically expected dispersion-curve trends, which can lead to significant Vs overestimation. Further analysis showed that using data with relatively short spread lengths and source offsets can image the desired fundamental-mode of the Rayleigh wave that matches the numerically expected dispersion-curve pattern. As a result, it was concluded that it might be possible to avoid higher-mode contamination at low frequencies at sites with high Vs contrast by appropriate selection of spread size and seismic source offset. ?? 2011 Society of Exploration Geophysicists.

  1. High-Speed, Multi-Channel Serial ADC LVDS Interface for Xilinx Virtex-5 FPGA

    NASA Technical Reports Server (NTRS)

    Taylor, Gregory H.

    2012-01-01

    Analog-to-digital converters (ADCs) are used in scientific and communications instruments on all spacecraft. As data rates get higher, and as the transition is made from parallel ADC designs to high-speed, serial, low-voltage differential signaling (LVDS) designs, the need will arise to interface these in field programmable gate arrays (FPGAs). As Xilinx has released the radiation-hardened version of the Virtex-5, this will likely be used in future missions. High-speed serial ADCs send data at very high rates. A de-serializer instantiated in the fabric of the FPGA could not keep up with these high data rates. The Virtex-5 contains primitives designed specifically for high-speed, source-synchronous de-serialization, but as supported by Xilinx, can only support bitwidths of 10. Supporting bit-widths of 12 or more requires the use of the primitives in an undocumented configuration, a non-trivial task. A new SystemVerilog design was written that is simpler and uses fewer hardware resources than the reference design described in Xilinx Application Note XAPP866. It has been shown to work in a Xilinx XC5VSX24OT connected to a MAXIM MAX1438 12-bit ADC using a 50-MHz sample clock. The design can be replicated in the FPGA for multiple ADCs (four instantiations were used for a total of 28 channels).

  2. Multi-channel electronic and vibrational dynamics in polyatomic resonant high-order harmonic generation

    PubMed Central

    Ferré, A.; Boguslavskiy, A. E.; Dagan, M.; Blanchet, V.; Bruner, B. D.; Burgy, F.; Camper, A.; Descamps, D.; Fabre, B.; Fedorov, N.; Gaudin, J.; Geoffroy, G.; Mikosch, J.; Patchkovskii, S.; Petit, S.; Ruchon, T.; Soifer, H.; Staedter, D.; Wilkinson, I.; Stolow, A.; Dudovich, N.; Mairesse, Y.

    2015-01-01

    High-order harmonic generation in polyatomic molecules generally involves multiple channels of ionization. Their relative contribution can be strongly influenced by the presence of resonances, whose assignment remains a major challenge for high-harmonic spectroscopy. Here we present a multi-modal approach for the investigation of unaligned polyatomic molecules, using SF6 as an example. We combine methods from extreme-ultraviolet spectroscopy, above-threshold ionization and attosecond metrology. Fragment-resolved above-threshold ionization measurements reveal that strong-field ionization opens at least three channels. A shape resonance in one of them is found to dominate the signal in the 20–26 eV range. This resonance induces a phase jump in the harmonic emission, a switch in the polarization state and different dynamical responses to molecular vibrations. This study demonstrates a method for extending high-harmonic spectroscopy to polyatomic molecules, where complex attosecond dynamics are expected. PMID:25608712

  3. Multi-channel electronic and vibrational dynamics in polyatomic resonant high-order harmonic generation.

    PubMed

    Ferré, A; Boguslavskiy, A E; Dagan, M; Blanchet, V; Bruner, B D; Burgy, F; Camper, A; Descamps, D; Fabre, B; Fedorov, N; Gaudin, J; Geoffroy, G; Mikosch, J; Patchkovskii, S; Petit, S; Ruchon, T; Soifer, H; Staedter, D; Wilkinson, I; Stolow, A; Dudovich, N; Mairesse, Y

    2015-01-01

    High-order harmonic generation in polyatomic molecules generally involves multiple channels of ionization. Their relative contribution can be strongly influenced by the presence of resonances, whose assignment remains a major challenge for high-harmonic spectroscopy. Here we present a multi-modal approach for the investigation of unaligned polyatomic molecules, using SF6 as an example. We combine methods from extreme-ultraviolet spectroscopy, above-threshold ionization and attosecond metrology. Fragment-resolved above-threshold ionization measurements reveal that strong-field ionization opens at least three channels. A shape resonance in one of them is found to dominate the signal in the 20-26 eV range. This resonance induces a phase jump in the harmonic emission, a switch in the polarization state and different dynamical responses to molecular vibrations. This study demonstrates a method for extending high-harmonic spectroscopy to polyatomic molecules, where complex attosecond dynamics are expected. PMID:25608712

  4. Metallic contaminant detection system using multi-channel high Tc SQUIDs

    NASA Astrophysics Data System (ADS)

    Tanaka, Saburo; Kitamura, Yoshihiro; Hatsukade, Yoshimi; Ohtani, Takeyoshi; Suzuki, Shuichi

    2012-10-01

    We have developed the magnetic metallic contaminant detectors using multiple high Tc SQUID gradiometers for industrial products. Finding ultra-small metallic contaminants is a big issue for manufacturers producing commercial products. The quality of industrial products such as lithium ion batteries can deteriorate by the inclusion of tiny metallic contaminants. When the contamination does occur, the manufacturer of the product suffers a great loss to recall the tainted products. Metallic particles with outer dimension less than 50 μm cannot be detected by a conventional X-ray imaging. Therefore a high sensitive detection system for small foreign matters is required. However, in most of the cases, the matrix of an active material coated sheet electrode is magnetized and the magnetic signal from the matrix is large enough to mask the signal from contaminants. Thus we have developed a detection system based on a SQUID gradiometer and a horizontal magnetization to date. For practical use, we should increase the detection width of the system by employing multiple sensors. We successfully realized an eight-channel high-Tc SQUID gradiometer system for inspection of sheet electrodes of a lithium ion battery with width of at least 60 to 70 mm. Eight planar SQUID gradiometers were mounted with a separation of 9.0 mm. As a result, small iron particles of less than 50 μm were successfully measured. This result suggests that the system is a promising tool for the detection of contaminants in a lithium ion battery.

  5. Design of a Multi-Channel Ultra-High Resolution Superconducting Gamma-Ray Spectrometer

    SciTech Connect

    Friedrich, S; Terracol, S F; Miyazaki, T; Drury, O B; Ali, Z A; Cunningham, M F; Niedermayr, T R; Barbee Jr., T W; Batteux, J D; Labov, S E

    2004-11-29

    Superconducting Gamma-ray microcalorimeters operated at temperatures around {approx}0.1 K offer an order of magnitude improvement in energy resolution over conventional high-purity Germanium spectrometers. The calorimeters consist of a {approx}1 mm{sup 3} superconducting or insulating absorber and a sensitive thermistor, which are weakly coupled to a cold bath. Gamma-ray capture increases the absorber temperature in proportion to the Gamma-ray energy, this is measured by the thermistor, and both subsequently cool back down to the base temperature through the weak link. We are developing ultra-high-resolution Gamma-ray spectrometers based on Sn absorbers and superconducting Mo/Cu multilayer thermistors for nuclear non-proliferation applications. They have achieved an energy resolution between 60 and 90 eV for Gamma-rays up to 100 keV. We also build two-stage adiabatic demagnetization refrigerators for user-friendly detector operation at 0.1 K. We present recent results on the performance of single pixel Gamma-ray spectrometers, and discuss the design of a large detector array for increased sensitivity.

  6. A new computer-controlled multi-channel high voltage supply system for GRACE instrumentation

    NASA Astrophysics Data System (ADS)

    Manna, A.; Chakrabarti, S.; Mukhopadhayay, P. K.

    2002-03-01

    The high energy gamma ray telescopes being set up by the Bhabha Atomic Research Institute Centre (BARC) at Mt. Abu, Rajasthan, as part of the GRACE project, require a very large number (~ 1000) of programmable high voltage power supplies for biasing photomultiplier tubes for the detection and characterization of the atmospheric Cerenkov events. These HV supplies need to be very compact, lightweight and rugged, as they will be mounted on the base of the moving telescope. This paper describes the design aspects of the overall HV system and the performance of the prototype HV modules developed for such applications. In the new design, the inverter switching frequency of the HV supplies has been increased threefold as compared to the earlier design, and surface mounted devices have been used to achieve overall size and weight reductions. The system consists of multiple HV modules, each containing 16 independently programmable HV supplies. Each HV module has an on-board micro-controller for doing control and supervisory functions and is interconnected via a serial 12C bus. The HV supplies have built in over voltage/current, thermal overload protections with output voltage readback and adjustable slew rate control facilities.

  7. TARGET: A multi-channel digitizer chip for very-high-energy gamma-ray telescopes

    SciTech Connect

    Bechtol, K.; Funk, S.; Okumura, A.; Ruckman, L.; Simons, A.; Tajima, H.; Vandenbroucke, J.; Varner, G.; /Hawaii U.

    2011-08-11

    The next-generation very-high-energy (VHE) gamma-ray observatory, the Cherenkov Telescope Array, will feature dozens of imaging atmospheric Cherenkov telescopes (IACTs), each with thousands of pixels of photosensors. To be affordable and reliable, reading out such a mega-channel array requires event recording technology that is highly integrated and modular, with a low cost per channel. We present the design and performance of a chip targeted to this application: the TeV Array Readout with GSa/s sampling and Event Trigger (TARGET). This application-specific integrated circuit (ASIC) has 16 parallel input channels, a 4096-sample buffer for each channel, adjustable input termination, self-trigger functionality, and tight window-selected readout. We report the performance of TARGET in terms of sampling frequency, power consumption, dynamic range, current-mode gain, analog bandwidth, and cross talk. The large number of channels per chip allows a low cost per channel ($10 to $20 including front-end and back-end electronics but not including photosensors) to be achieved with a TARGET-based IACT readout system. In addition to basic performance parameters of the TARGET chip itself, we present a camera module prototype as well as a second-generation chip (TARGET 2), both of which have been produced.

  8. Multi-Channel Microstrip Transceiver Arrays Using Harmonics for High Field MR Imaging in Humans

    PubMed Central

    Wu, Bing; Wang, Chunsheng; Lu, Jonathan; Pang, Yong; Nelson, Sarah J; Vigneron, Daniel B; Zhang, Xiaoliang

    2012-01-01

    RF transceiver array design using primary and higher order harmonics for in-vivo parallel MR imaging and spectroscopic imaging is proposed. The improved electromagnetic decoupling performance, unique magnetic field distributions and high-frequency operation capabilities of higher-order harmonics of resonators would benefit transceiver arrays for parallel MRI, especially for ultrahigh field parallel MRI. To demonstrate this technique, microstrip transceiver arrays using first and second harmonic resonators were developed for human head parallel imaging at 7T. Phantom and human head images were acquired and evaluated using the GRAPPA reconstruction algorithm. The higher-order harmonic transceiver array design technique was also assessed numerically using FDTD simulation. Compared with regular primary-resonance transceiver designs, the proposed higher-order harmonic technique provided an improved g-factor and increased decoupling among resonant elements without using dedicated decoupling circuits, which would potentially lead to a better parallel imaging performance and ultimately faster and higher quality imaging. The proposed technique is particularly suitable for densely spaced transceiver array design where the increased mutual inductance among the elements becomes problematic. In addition, it also provides a simple approach to readily upgrade the channels of a conventional primary resonator microstrip array to a larger number for faster imaging. PMID:21878410

  9. Generation of multi-channel high-speed physical random numbers originated from two chaotic signals of mutually coupled semiconductor lasers

    NASA Astrophysics Data System (ADS)

    Tang, X.; Wu, Z. M.; Wu, J. G.; Deng, T.; Fan, L.; Zhong, Z. Q.; Chen, J. J.; Xia, G. Q.

    2015-01-01

    We propose and experimentally demonstrate a novel technique to generate multi-channel high-speed physical random numbers (PRNs) by taking two chaotic signal outputs from mutually coupled semiconductor lasers (MC-SLs) as entropy sources. First, through controlling the operation parameters of the MC-SL system, two time-delay signature (TDS) suppressed chaotic signals can be obtained. Next, each of these two chaotic signals is sampled by an 8 bit analog-to-digital converter (ADC) with a sampling rate of 10 GHz, and then a bitwise exclusive-OR (XOR) operation on the corresponding bits in samples of the chaotic signal and its time delayed signal is implemented to obtain 8 bit XOR data. Furthermore, through selecting the five least significant bits (LSBs) of 8 bit XOR data to form 5 bit Boolean sequences, two sets of PRN streams with a rate up to 50 Gbits s-1 are generated and successfully pass the NIST statistical tests. Finally, merging these two sets of 50 Gbits s-1 PRN streams by an interleaving operation, another set of the 100 Gbits s-1 PRN stream, which meets all the quality criteria of NIST statistical tests, is also acquired.

  10. Improvements of Travel-time Tomography Models from Joint Inversion of Multi-channel and Wide-angle Seismic Data

    NASA Astrophysics Data System (ADS)

    Begović, Slaven; Ranero, César; Sallarès, Valentí; Meléndez, Adrià; Grevemeyer, Ingo

    2016-04-01

    Commonly multichannel seismic reflection (MCS) and wide-angle seismic (WAS) data are modeled and interpreted with different approaches. Conventional travel-time tomography models using solely WAS data lack the resolution to define the model properties and, particularly, the geometry of geologic boundaries (reflectors) with the required accuracy, specially in the shallow complex upper geological layers. We plan to mitigate this issue by combining these two different data sets, specifically taking advantage of the high redundancy of multichannel seismic (MCS) data, integrated with wide-angle seismic (WAS) data into a common inversion scheme to obtain higher-resolution velocity models (Vp), decrease Vp uncertainty and improve the geometry of reflectors. To do so, we have adapted the tomo2d and tomo3d joint refraction and reflection travel time tomography codes (Korenaga et al, 2000; Meléndez et al, 2015) to deal with streamer data and MCS acquisition geometries. The scheme results in a joint travel-time tomographic inversion based on integrated travel-time information from refracted and reflected phases from WAS data and reflected identified in the MCS common depth point (CDP) or shot gathers. To illustrate the advantages of a common inversion approach we have compared the modeling results for synthetic data sets using two different travel-time inversion strategies: We have produced seismic velocity models and reflector geometries following typical refraction and reflection travel-time tomographic strategy modeling just WAS data with a typical acquisition geometry (one OBS each 10 km). Second, we performed joint inversion of two types of seismic data sets, integrating two coincident data sets consisting of MCS data collected with a 8 km-long streamer and the WAS data into a common inversion scheme. Our synthetic results of the joint inversion indicate a 5-10 times smaller ray travel-time misfit in the deeper parts of the model, compared to models obtained using just

  11. Timing Performance of a MCP Photon Detector Read Out with Multi-Channel Electronics for the Torch System

    NASA Astrophysics Data System (ADS)

    Castillo García, L.; Fopma, J. M.; Forty, R.; Frei, C.; Gao, R.; Gys, T.; Harnew, N.; Piedigrossi, D.

    2014-06-01

    As part of the R&D phase of the (Time Of internally Reflected Cherenkov light) TORCH project, 8×8 pad micro-channel plate photon detectors are being characterized. Multichannel electronics based on fast amplifier discriminator and time digitization conversion ASICs are used to read out and time the charge signals from single photoelectrons. The MCP performance is investigated with a 20ps pulsed blue laser diode. A time resolution of 90ps is achieved. Timing properties are obtained at modest MCP gain, without time walk correction and no fine calibration of the time-to-digital converter circuit. The reference time is provided by a single-channel MCP photon detector coupled to a Constant Fraction Discriminator. Photoelectron detection efficiencies and back-scattering effect are discussed together with the laser source influence on the timing performance.

  12. Implementation of a real-time multi-channel gateway server in ubiquitous integrated biotelemetry system for emergency care (UIBSEC).

    PubMed

    Cheon, Gyeongwoo; Shin, Il Hyung; Jung, Min Yang; Kim, Hee Chan

    2009-01-01

    We developed a gateway server to support various types of bio-signal monitoring devices for ubiquitous emergency healthcare in a reliable, effective, and scalable way. The server provides multiple channels supporting real-time N-to-N client connections. We applied our system to four types of health monitoring devices including a 12-channel electrocardiograph (ECG), oxygen saturation (SpO(2)), and medical imaging devices (a ultrasonograph and a digital skin microscope). Different types of telecommunication networks were tested: WIBRO, CDMA, wireless LAN, and wired internet. We measured the performance of our system in terms of the transmission rate and the number of simultaneous connections. The results show that the proposed network communication strategy can be successfully applied to the ubiquitous emergency healthcare service by providing a fast rate enough for real-time video transmission and multiple connections among patients and medical personnel. PMID:19964662

  13. Fast, multi-channel real-time processing of signals with microsecond latency using graphics processing units

    NASA Astrophysics Data System (ADS)

    Rath, N.; Kato, S.; Levesque, J. P.; Mauel, M. E.; Navratil, G. A.; Peng, Q.

    2014-04-01

    Fast, digital signal processing (DSP) has many applications. Typical hardware options for performing DSP are field-programmable gate arrays (FPGAs), application-specific integrated DSP chips, or general purpose personal computer systems. This paper presents a novel DSP platform that has been developed for feedback control on the HBT-EP tokamak device. The system runs all signal processing exclusively on a Graphics Processing Unit (GPU) to achieve real-time performance with latencies below 8 μs. Signals are transferred into and out of the GPU using PCI Express peer-to-peer direct-memory-access transfers without involvement of the central processing unit or host memory. Tests were performed on the feedback control system of the HBT-EP tokamak using forty 16-bit floating point inputs and outputs each and a sampling rate of up to 250 kHz. Signals were digitized by a D-TACQ ACQ196 module, processing done on an NVIDIA GTX 580 GPU programmed in CUDA, and analog output was generated by D-TACQ AO32CPCI modules.

  14. Fast, multi-channel real-time processing of signals with microsecond latency using graphics processing units.

    PubMed

    Rath, N; Kato, S; Levesque, J P; Mauel, M E; Navratil, G A; Peng, Q

    2014-04-01

    Fast, digital signal processing (DSP) has many applications. Typical hardware options for performing DSP are field-programmable gate arrays (FPGAs), application-specific integrated DSP chips, or general purpose personal computer systems. This paper presents a novel DSP platform that has been developed for feedback control on the HBT-EP tokamak device. The system runs all signal processing exclusively on a Graphics Processing Unit (GPU) to achieve real-time performance with latencies below 8 μs. Signals are transferred into and out of the GPU using PCI Express peer-to-peer direct-memory-access transfers without involvement of the central processing unit or host memory. Tests were performed on the feedback control system of the HBT-EP tokamak using forty 16-bit floating point inputs and outputs each and a sampling rate of up to 250 kHz. Signals were digitized by a D-TACQ ACQ196 module, processing done on an NVIDIA GTX 580 GPU programmed in CUDA, and analog output was generated by D-TACQ AO32CPCI modules. PMID:24784666

  15. Fast, multi-channel real-time processing of signals with microsecond latency using graphics processing units

    SciTech Connect

    Rath, N. Levesque, J. P.; Mauel, M. E.; Navratil, G. A.; Peng, Q.; Kato, S.

    2014-04-15

    Fast, digital signal processing (DSP) has many applications. Typical hardware options for performing DSP are field-programmable gate arrays (FPGAs), application-specific integrated DSP chips, or general purpose personal computer systems. This paper presents a novel DSP platform that has been developed for feedback control on the HBT-EP tokamak device. The system runs all signal processing exclusively on a Graphics Processing Unit (GPU) to achieve real-time performance with latencies below 8 μs. Signals are transferred into and out of the GPU using PCI Express peer-to-peer direct-memory-access transfers without involvement of the central processing unit or host memory. Tests were performed on the feedback control system of the HBT-EP tokamak using forty 16-bit floating point inputs and outputs each and a sampling rate of up to 250 kHz. Signals were digitized by a D-TACQ ACQ196 module, processing done on an NVIDIA GTX 580 GPU programmed in CUDA, and analog output was generated by D-TACQ AO32CPCI modules.

  16. Mapping of calf muscle oxygenation and haemoglobin content during dynamic plantar flexion exercise by multi-channel time-resolved near-infrared spectroscopy

    NASA Astrophysics Data System (ADS)

    Torricelli, Alessandro; Quaresima, Valentina; Pifferi, Antonio; Biscotti, Giovanni; Spinelli, Lorenzo; Taroni, Paola; Ferrari, Marco; Cubeddu, Rinaldo

    2004-03-01

    A compact and fast multi-channel time-resolved near-infrared spectroscopy system for tissue oximetry was developed. It employs semiconductor laser and fibre optics for delivery of optical signals. Photons are collected by eight 1 mm fibres and detected by a multianode photomultiplier. A time-correlated single photon counting board is used for the parallel acquisition of time-resolved reflectance curves. Estimate of the reduced scattering coefficient is achieved by fitting with a standard model of diffusion theory, while the modified Lambert-Beer law is used to assess the absorption coefficient. In vivo measurements were performed on five healthy volunteers to monitor spatial changes in calf muscle (medial and lateral gastrocnemius; MG, LG) oxygen saturation (SmO2) and total haemoglobin concentration (tHb) during dynamic plantar flexion exercise performed at 50% of the maximal voluntary contraction. At rest SmO2 was 73.0 ± 0.9 and 70.5 ± 1.7% in MG and LG, respectively (P = 0.045). At the end of the exercise, SmO2 decreased (69.1 ± 1.8 and 63.8 ± 2.1% in MG and LG, respectively; P < 0.01). The LG desaturation was greater than the MG desaturation (P < 0.02). These results strengthen the role of time-resolved near-infrared spectroscopy as a powerful tool for investigating the spatial and temporal features of muscle SmO2 and tHb.

  17. MULTI-CHANNEL PULSE HEIGHT ANALYZER

    DOEpatents

    Boyer, K.; Johnstone, C.W.

    1958-11-25

    An improved multi-channel pulse height analyzer of the type where the device translates the amplitude of each pulse into a time duration electrical quantity which is utilized to control the length of a train of pulses forwarded to a scaler is described. The final state of the scaler for any one train of pulses selects the appropriate channel in a magnetic memory in which an additional count of one is placed. The improvement consists of a storage feature for storing a signal pulse so that in many instances when two signal pulses occur in rapid succession, the second pulse is preserved and processed at a later time.

  18. A low power Multi-Channel Analyzer

    SciTech Connect

    Anderson, G.A.; Brackenbush, L.W.

    1993-06-01

    The instrumentation used in nuclear spectroscopy is generally large, is not portable, and requires a lot of power. Key components of these counting systems are the computer and the Multi-Channel Analyzer (MCA). To assist in performing measurements requiring portable systems, a small, very low power MCA has been developed at Pacific Northwest Laboratory (PNL). This MCA is interfaced with a Hewlett Packard palm top computer for portable applications. The MCA can also be connected to an IBM/PC for data storage and analysis. In addition, a real-time time display mode allows the user to view the spectra as they are collected.

  19. A multi-channel gel electrophoresis and continuous fraction collection apparatus for high throughput protein separation and characterization

    SciTech Connect

    Choi, Megan; Nordmeyer, Robert A.; Cornell, Earl; Dong, Ming; Biggin, Mark D.; Jin, Jian

    2009-10-02

    To facilitate a direct interface between protein separation by PAGE and protein identification by mass spectrometry, we developed a multichannel system that continuously collects fractions as protein bands migrate off the bottom of gel electrophoresis columns. The device was constructed using several short linear gel columns, each of a different percent acrylamide, to achieve a separation power similar to that of a long gradient gel. A Counter Free-Flow elution technique then allows continuous and simultaneous fraction collection from multiple channels at low cost. We demonstrate that rapid, high-resolution separation of a complex protein mixture can be achieved on this system using SDS-PAGE. In a 2.5 h electrophoresis run, for example, each sample was separated and eluted into 48-96 fractions over a mass range of 10-150 kDa; sample recovery rates were 50percent or higher; each channel was loaded with up to 0.3 mg of protein in 0.4 mL; and a purified band was eluted in two to three fractions (200 L/fraction). Similar results were obtained when running native gel electrophoresis, but protein aggregation limited the loading capacity to about 50 g per channel and reduced resolution.

  20. Web-based multi-channel analyzer

    DOEpatents

    Gritzo, Russ E.

    2003-12-23

    The present invention provides an improved multi-channel analyzer designed to conveniently gather, process, and distribute spectrographic pulse data. The multi-channel analyzer may operate on a computer system having memory, a processor, and the capability to connect to a network and to receive digitized spectrographic pulses. The multi-channel analyzer may have a software module integrated with a general-purpose operating system that may receive digitized spectrographic pulses for at least 10,000 pulses per second. The multi-channel analyzer may further have a user-level software module that may receive user-specified controls dictating the operation of the multi-channel analyzer, making the multi-channel analyzer customizable by the end-user. The user-level software may further categorize and conveniently distribute spectrographic pulse data employing non-proprietary, standard communication protocols and formats.

  1. Handling Deafness Problem of Scheduled Multi-Channel Polling MACs

    NASA Astrophysics Data System (ADS)

    Jiang, Fulong; Liu, Hao; Shi, Longxing

    Combining scheduled channel polling with channel diversity is a promising way for a MAC protocol to achieve high energy efficiency and performance under both light and heavy traffic conditions. However, the deafness problem may cancel out the benefit of channel diversity. In this paper, we first investigate the deafness problem of scheduled multi-channel polling MACs with experiments. Then we propose and evaluate two schemes to handle the deafness problem. Our experiment shows that deafness is a significant reason for performance degradation in scheduled multi-channel polling MACs. A proper scheme should be chosen depending on the traffic pattern and the design objective.

  2. An integrated analog O/E/O link for multi-channel laser neurons

    NASA Astrophysics Data System (ADS)

    Nahmias, Mitchell A.; Tait, Alexander N.; Tolias, Leonidas; Chang, Matthew P.; Ferreira de Lima, Thomas; Shastri, Bhavin J.; Prucnal, Paul R.

    2016-04-01

    We demonstrate an analog O/E/O electronic link to allow integrated laser neurons to accept many distinguishable, high bandwidth input signals simultaneously. This device utilizes wavelength division multiplexing to achieve multi-channel fan-in, a photodetector to sum signals together, and a laser cavity to perform a nonlinear operation. Its speed outpaces accelerated-time neuromorphic electronics, and it represents a viable direction towards scalable networking approaches.

  3. Multi-channel polarized thermal emitter

    DOEpatents

    Lee, Jae-Hwang; Ho, Kai-Ming; Constant, Kristen P

    2013-07-16

    A multi-channel polarized thermal emitter (PTE) is presented. The multi-channel PTE can emit polarized thermal radiation without using a polarizer at normal emergence. The multi-channel PTE consists of two layers of metallic gratings on a monolithic and homogeneous metallic plate. It can be fabricated by a low-cost soft lithography technique called two-polymer microtransfer molding. The spectral positions of the mid-infrared (MIR) radiation peaks can be tuned by changing the periodicity of the gratings and the spectral separation between peaks are tuned by changing the mutual angle between the orientations of the two gratings.

  4. Coherent state transfer through a multi-channel quantum network: Natural versus controlled evolution passage

    NASA Astrophysics Data System (ADS)

    Chen, Bing; Li, Yong

    2016-04-01

    Quantum state transfer (QST) is an important task in quantum information processing. In this study, we describe two approaches for the high-fidelity transfer of a quantum state between two opposite quantum dots attached to a multi-channel quantum network. First, we demonstrate that a high-efficiency QST can be achieved with the coherent time evolution of a quantum system without any external control. Second, we present an approach that uses an alternative mechanism for a high-fidelity QST. By adiabatically varying tunnel couplings, it is possible to implement the complete transmission of a quantum state based on this quantum mechanical mechanism.

  5. Multi-channel electric aerosol spectrometer

    NASA Astrophysics Data System (ADS)

    Mirme, A.; Noppel, M.; Peil, I.; Salm, J.; Tamm, E.; Tammet, H.

    Multi-channel electric mobility spectrometry is a most efficient technique for the rapid measurement of an unstable aerosol particle size spectrum. The measuring range of the spectrometer from 10 microns to 10 microns is achieved by applying diffusional and field charging mechanisms simultaneously. On-line data processing is carried out with a microcomputer. Experimental calibration ensures correctness of measurement.

  6. Multi-channel lock-in amplifier assisted femtosecond time-resolved fluorescence non-collinear optical parametric amplification spectroscopy with efficient rejection of superfluorescence background

    NASA Astrophysics Data System (ADS)

    Mao, Pengcheng; Wang, Zhuan; Dang, Wei; Weng, Yuxiang

    2015-12-01

    Superfluorescence appears as an intense background in femtosecond time-resolved fluorescence noncollinear optical parametric amplification spectroscopy, which severely interferes the reliable acquisition of the time-resolved fluorescence spectra especially for an optically dilute sample. Superfluorescence originates from the optical amplification of the vacuum quantum noise, which would be inevitably concomitant with the amplified fluorescence photons during the optical parametric amplification process. Here, we report the development of a femtosecond time-resolved fluorescence non-collinear optical parametric amplification spectrometer assisted with a 32-channel lock-in amplifier for efficient rejection of the superfluorescence background. With this spectrometer, the superfluorescence background signal can be significantly reduced to 1/300-1/100 when the seeding fluorescence is modulated. An integrated 32-bundle optical fiber is used as a linear array light receiver connected to 32 photodiodes in one-to-one mode, and the photodiodes are further coupled to a home-built 32-channel synchronous digital lock-in amplifier. As an implementation, time-resolved fluorescence spectra for rhodamine 6G dye in ethanol solution at an optically dilute concentration of 10-5M excited at 510 nm with an excitation intensity of 70 nJ/pulse have been successfully recorded, and the detection limit at a pump intensity of 60 μJ/pulse was determined as about 13 photons/pulse. Concentration dependent redshift starting at 30 ps after the excitation in time-resolved fluorescence spectra of this dye has also been observed, which can be attributed to the formation of the excimer at a higher concentration, while the blueshift in the earlier time within 10 ps is attributed to the solvation process.

  7. Multi-channel lock-in amplifier assisted femtosecond time-resolved fluorescence non-collinear optical parametric amplification spectroscopy with efficient rejection of superfluorescence background

    SciTech Connect

    Mao, Pengcheng; Wang, Zhuan; Dang, Wei; Weng, Yuxiang

    2015-12-15

    Superfluorescence appears as an intense background in femtosecond time-resolved fluorescence noncollinear optical parametric amplification spectroscopy, which severely interferes the reliable acquisition of the time-resolved fluorescence spectra especially for an optically dilute sample. Superfluorescence originates from the optical amplification of the vacuum quantum noise, which would be inevitably concomitant with the amplified fluorescence photons during the optical parametric amplification process. Here, we report the development of a femtosecond time-resolved fluorescence non-collinear optical parametric amplification spectrometer assisted with a 32-channel lock-in amplifier for efficient rejection of the superfluorescence background. With this spectrometer, the superfluorescence background signal can be significantly reduced to 1/300–1/100 when the seeding fluorescence is modulated. An integrated 32-bundle optical fiber is used as a linear array light receiver connected to 32 photodiodes in one-to-one mode, and the photodiodes are further coupled to a home-built 32-channel synchronous digital lock-in amplifier. As an implementation, time-resolved fluorescence spectra for rhodamine 6G dye in ethanol solution at an optically dilute concentration of 10{sup −5}M excited at 510 nm with an excitation intensity of 70 nJ/pulse have been successfully recorded, and the detection limit at a pump intensity of 60 μJ/pulse was determined as about 13 photons/pulse. Concentration dependent redshift starting at 30 ps after the excitation in time-resolved fluorescence spectra of this dye has also been observed, which can be attributed to the formation of the excimer at a higher concentration, while the blueshift in the earlier time within 10 ps is attributed to the solvation process.

  8. Multi-channel lock-in amplifier assisted femtosecond time-resolved fluorescence non-collinear optical parametric amplification spectroscopy with efficient rejection of superfluorescence background.

    PubMed

    Mao, Pengcheng; Wang, Zhuan; Dang, Wei; Weng, Yuxiang

    2015-12-01

    Superfluorescence appears as an intense background in femtosecond time-resolved fluorescence noncollinear optical parametric amplification spectroscopy, which severely interferes the reliable acquisition of the time-resolved fluorescence spectra especially for an optically dilute sample. Superfluorescence originates from the optical amplification of the vacuum quantum noise, which would be inevitably concomitant with the amplified fluorescence photons during the optical parametric amplification process. Here, we report the development of a femtosecond time-resolved fluorescence non-collinear optical parametric amplification spectrometer assisted with a 32-channel lock-in amplifier for efficient rejection of the superfluorescence background. With this spectrometer, the superfluorescence background signal can be significantly reduced to 1/300-1/100 when the seeding fluorescence is modulated. An integrated 32-bundle optical fiber is used as a linear array light receiver connected to 32 photodiodes in one-to-one mode, and the photodiodes are further coupled to a home-built 32-channel synchronous digital lock-in amplifier. As an implementation, time-resolved fluorescence spectra for rhodamine 6G dye in ethanol solution at an optically dilute concentration of 10(-5)M excited at 510 nm with an excitation intensity of 70 nJ/pulse have been successfully recorded, and the detection limit at a pump intensity of 60 μJ/pulse was determined as about 13 photons/pulse. Concentration dependent redshift starting at 30 ps after the excitation in time-resolved fluorescence spectra of this dye has also been observed, which can be attributed to the formation of the excimer at a higher concentration, while the blueshift in the earlier time within 10 ps is attributed to the solvation process. PMID:26724012

  9. Time-resolved multi-channel optical system for assessment of brain oxygenation and perfusion by monitoring of diffuse reflectance and fluorescence

    NASA Astrophysics Data System (ADS)

    Milej, D.; Gerega, A.; Kacprzak, M.; Sawosz, P.; Weigl, W.; Maniewski, R.; Liebert, A.

    2014-03-01

    Time-resolved near-infrared spectroscopy is an optical technique which can be applied in tissue oxygenation assessment. In the last decade this method is extensively tested as a potential clinical tool for noninvasive human brain function monitoring and imaging. In the present paper we show construction of an instrument which allows for: (i) estimation of changes in brain tissue oxygenation using two-wavelength spectroscopy approach and (ii) brain perfusion assessment with the use of single-wavelength reflectometry or fluorescence measurements combined with ICG-bolus tracking. A signal processing algorithm based on statistical moments of measured distributions of times of flight of photons is implemented. This data analysis method allows for separation of signals originating from extra- and intracerebral tissue compartments. In this paper we present compact and easily reconfigurable system which can be applied in different types of time-resolved experiments: two-wavelength measurements at 687 and 832 nm, single wavelength reflectance measurements at 760 nm (which is at maximum of ICG absorption spectrum) or fluorescence measurements with excitation at 760 nm. Details of the instrument construction and results of its technical tests are shown. Furthermore, results of in-vivo measurements obtained for various modes of operation of the system are presented.

  10. Solving non-Markovian open quantum systems with multi-channel reservoir coupling

    SciTech Connect

    Broadbent, Curtis J.; Jing, Jun; Yu, Ting; Eberly, Joseph H.

    2012-08-15

    We extend the non-Markovian quantum state diffusion (QSD) equation to open quantum systems which exhibit multi-channel coupling to a harmonic oscillator reservoir. Open quantum systems which have multi-channel reservoir coupling are those in which canonical transformation of reservoir modes cannot reduce the number of reservoir operators appearing in the interaction Hamiltonian to one. We show that the non-Markovian QSD equation for multi-channel reservoir coupling can, in some cases, lead to an exact master equation which we derive. We then derive the exact master equation for the three-level system in a vee-type configuration which has multi-channel reservoir coupling and give the analytical solution. Finally, we examine the evolution of the three-level vee-type system with generalized Ornstein-Uhlenbeck reservoir correlations numerically. - Highlights: Black-Right-Pointing-Pointer The concept of multi-channel vs. single-channel reservoir coupling is rigorously defined. Black-Right-Pointing-Pointer The non-Markovian quantum state diffusion equation for arbitrary multi-channel reservoir coupling is derived. Black-Right-Pointing-Pointer An exact time-local master equation is derived under certain conditions. Black-Right-Pointing-Pointer The analytical solution to the three-level system in a vee-type configuration is found. Black-Right-Pointing-Pointer The evolution of the three-level system under generalized Ornstein-Uhlenbeck noise is plotted for many parameter regimes.

  11. Hand Motion Classification Using a Multi-Channel Surface Electromyography Sensor

    PubMed Central

    Tang, Xueyan; Liu, Yunhui; Lv, Congyi; Sun, Dong

    2012-01-01

    The human hand has multiple degrees of freedom (DOF) for achieving high-dexterity motions. Identifying and replicating human hand motions are necessary to perform precise and delicate operations in many applications, such as haptic applications. Surface electromyography (sEMG) sensors are a low-cost method for identifying hand motions, in addition to the conventional methods that use data gloves and vision detection. The identification of multiple hand motions is challenging because the error rate typically increases significantly with the addition of more hand motions. Thus, the current study proposes two new methods for feature extraction to solve the problem above. The first method is the extraction of the energy ratio features in the time-domain, which are robust and invariant to motion forces and speeds for the same gesture. The second method is the extraction of the concordance correlation features that describe the relationship between every two channels of the multi-channel sEMG sensor system. The concordance correlation features of a multi-channel sEMG sensor system were shown to provide a vast amount of useful information for identification. Furthermore, a new cascaded-structure classifier is also proposed, in which 11 types of hand gestures can be identified accurately using the newly defined features. Experimental results show that the success rate for the identification of the 11 gestures is significantly high. PMID:22438703

  12. Multi-channeled single chain variable fragment (scFv) based microfluidic device for explosives detection.

    PubMed

    Charles, Paul T; Davis, Jasmine; Adams, André A; Anderson, George P; Liu, Jinny L; Deschamps, Jeffrey R; Kusterbeck, Anne W

    2015-11-01

    The development of explosives detection technologies has increased significantly over the years as environmental and national security agencies implement tighter pollution control measures and methods for improving homeland security. 2, 4, 6-Trinitrotoluene (TNT), known primarily as a component in munitions, has been targeted for both its toxicity and carcinogenic properties that if present at high concentrations can be a detriment to both humans, marine and plant ecosystems. Enabling end users with environmental detection and monitoring systems capable of providing real-time, qualitative and quantitative chemical analysis of these toxic compounds would be extremely beneficial. Reported herein is the development of a multi-channeled microfluidic device immobilized with single chain fragment variable (scFv) recombinant proteins specific for the explosive, TNT. Fluorescence displacement immunoassays performed under constant flow demonstrated trace level sensitivity and specificity for TNT. The utility of three multi-channeled devices immobilized with either (1) scFv recombinant protein, (2) biotinylated-scFv (bt-scFv) and (3) monoclonal anti-TNT (whole IgG molecule) were investigated and compared. Fluorescence dose response curves, crossreactivity measurements and limits of detection (LOD) for TNT were determined. Fluorescence displacement immunoassays for TNT in natural seawater demonstrated detection limits at sub-parts-per-billion levels (0.5 ppb) utilizing the microfluidic device with immobilized bt-scFv. PMID:26452845

  13. Multi-channel compact optical zoom module by using microlenses

    NASA Astrophysics Data System (ADS)

    Liao, Wei-Hsiang; Su, Guo-Dung J.

    2015-09-01

    In this paper, we propose a multi-channel imaging system, which combines the principles of an insect's compound eye and optical zoom. We use the distance between two aspherical lenses to achieve zoom effect. In order to shrink the thickness of the system, we use the multi-channel structure which consists of curved micolens array. With this architecture, we can achieve the same effect like lens group. Each partial image passes through each channel separately and is stitched together at the image sensor. In our design, the thickness is 6.57 mm (wide), 6.25 mm (mid), 6.4 mm (tele) and the effective focal length is 2.2 mm( wide), 2.97 mm (mid), 4.04 mm (tele). Zoom ratio is close to 2 times. The size of image sensor is 6 mm in diameter. Due to the advance in microlens fabrication of microlens, this design has the potential to bed used inside mobile phone camera in future.

  14. Single and Multi-Channel Carbon-based Quantum Dragons

    NASA Astrophysics Data System (ADS)

    Inkoom, Godfred; Abdurazakov, Omadillo; Novotny, Mark

    2015-03-01

    In the coherent regime for electrical conductance measurements, two semi-infinite leads are connected to a finite nanostructure, and the nano-device conductance is calculated using the Landauer formula. Any channel k that has transmission for electrons with energy E, \\calTk (E) =1 contributes the conductance quantum G0 = 2e2 / h . Any nano-device with at least one \\calTk (E) =1 is called a quantum dragon. The transmission probability \\calTk (E) can be obtained from the solution of the time-independent Schrödinger equation. Uniform leads connected to armchair single-walled carbon nanotubes (SWCNTs) have calT (E) =1, while when connected to zigzag SWCNT the calT (E) is less than unity. Appropriately dimerized leads connected to zigzag SWCNTs are quantum dragons, while when connected to armchair SWCNTs calT (E) is less than unity. We have generalized the matrix method and mapping methods of in order to investigate SWCNTs that can be multi-channel quantum dragons. For example, one can use armchair SWCNT leads to connect to an armchair SWCNT to try to produce a multi-channel quantum dragon. Supported in part by NSF Grant DMR-1206233.

  15. Anomaly Detection using Multi-channel FLAC for Supporting Diagnosis of ECG

    NASA Astrophysics Data System (ADS)

    Ye, Jiaxing; Kobayashi, Takumi; Murakawa, Masahiro; Higuchi, Tetsuya; Otsu, Nobuyuki

    In this paper, we propose an approach for abnormality detection in multi-channel ECG signals. This system serves as front end to detect the irregular sections in ECG signals, where symptoms may be observed. Thereby, the doctor can focus on only the detected suspected symptom sections, ignoring the disease-free parts. Hence the workload of the inspection by the doctors is significantly reduced and the diagnosis efficiency can be sharply improved. For extracting the predominant characteristics of multi-channel ECG signals, we propose multi-channel Fourier local auto-correlations (m-FLAC) features on multi-channel complex spectrograms. The method characterizes the amplitude and phase information as well as temporal dynamics of the multi-channel ECG signal. At the anomaly detection stage, we employ complex subspace method for statistically modeling the normal (healthy) ECG patterns as in one-class learning. Then, we investigate the input ECG signals by measuring its deviation distance to the trained subspace. The ECG sections with disordered spectral distributions can be effectively discerned based on such distance metric. To validate the proposed approach, we conducted experiments on ECG dataset. The experimental results demonstrated the effectiveness of the proposed approach including promising performance and high efficiency, compared to conventional methods.

  16. Innovative RF Design Unites Benefits of Multiplexed and Multi-Channel System

    NASA Astrophysics Data System (ADS)

    Mavrič, Uroš

    2004-11-01

    The main advantages of the implemented innovative RF design are reproducibility, accuracy, low measurement uncertainty, and compact design. They were achieved by implementing the direct RF sampling and the completely new, patent pending technological approach of quasi-crossbar multiplexing and associated measurement method. The innovative quasi-crossbar switch matrix unites the benefits of both the multi-channel and the multiplexed system and at the same time compensates the disadvantages of the two. We achieve reproducibility and good "beam vs. current" dependence, which are multiplexed system characteristics and, using a multi-channel approach, we ensure a broader band of operation.

  17. Tunable multi-channel terahertz wave power splitter

    NASA Astrophysics Data System (ADS)

    Jiu-Sheng, Li; Han, Liu; Le, Zhang

    2015-12-01

    The combination of terahertz technology and photonic crystal provides a new approach to realize compact terahertz wave devices. Relying on a conventional photonic crystal waveguide and photonic crystal surface-mode waveguides, a tunable multi-channel terahertz-wave power splitter is proposed. The mechanism of such a power splitter is further theoretically analyzed and numerically investigated with the aid of the plane-wave-expansion method and the finite-difference time-domain method. With an appropriate design, the proposed device can split the input terahertz wave energy equally into six output ports at the frequency of 0.6 THz. When changing the external magnetic field, the input terahertz wave can be equally divided into four output ports with the aid of a magnetic-sensitive material. Furthermore, the present device is very compact and the total size is of 4.4×6.0 mm2.

  18. Multi-Channel Capacitive Sensor Arrays.

    PubMed

    Wang, Bingnan; Long, Jiang; Teo, Koon Hoo

    2016-01-01

    In this paper, multi-channel capacitive sensor arrays based on microstrip band-stop filters are studied. The sensor arrays can be used to detect the proximity of objects at different positions and directions. Each capacitive sensing structure in the array is connected to an inductive element to form resonance at different frequencies. The resonances are designed to be isolated in the frequency spectrum, such that the change in one channel does not affect resonances at other channels. The inductive element associated with each capacitive sensor can be surface-mounted inductors, integrated microstrip inductors or metamaterial-inspired structures. We show that by using metamaterial split-ring structures coupled to a microstrip line, the quality factor of each resonance can be greatly improved compared to conventional surface-mounted or microstrip meander inductors. With such a microstrip-coupled split-ring design, more sensing elements can be integrated in the same frequency spectrum, and the sensitivity can be greatly improved. PMID:26821023

  19. Multi-Channel Capacitive Sensor Arrays

    PubMed Central

    Wang, Bingnan; Long, Jiang; Teo, Koon Hoo

    2016-01-01

    In this paper, multi-channel capacitive sensor arrays based on microstrip band-stop filters are studied. The sensor arrays can be used to detect the proximity of objects at different positions and directions. Each capacitive sensing structure in the array is connected to an inductive element to form resonance at different frequencies. The resonances are designed to be isolated in the frequency spectrum, such that the change in one channel does not affect resonances at other channels. The inductive element associated with each capacitive sensor can be surface-mounted inductors, integrated microstrip inductors or metamaterial-inspired structures. We show that by using metamaterial split-ring structures coupled to a microstrip line, the quality factor of each resonance can be greatly improved compared to conventional surface-mounted or microstrip meander inductors. With such a microstrip-coupled split-ring design, more sensing elements can be integrated in the same frequency spectrum, and the sensitivity can be greatly improved. PMID:26821023

  20. Designing Multi-Channel Web Frameworks for Cultural Tourism Applications: The MUSE Case Study.

    ERIC Educational Resources Information Center

    Garzotto, Franca; Salmon, Tullio; Pigozzi, Massimiliano

    A framework for the design of multi-channel (MC) applications in the cultural tourism domain is presented. Several heterogeneous interface devices are supported including location-sensitive mobile units, on-site stationary devices, and personalized CDs that extend the on-site experience beyond the visit time thanks to personal memories gathered…

  1. Integrative analysis of T cell motility from multi-channel microscopy data using TIAM.

    PubMed

    Mayya, Viveka; Neiswanger, Willie; Medina, Ricardo; Wiggins, Chris H; Dustin, Michael L

    2015-01-01

    Integrative analytical approaches are needed to study and understand T cell motility as it is a highly coordinated and complex process. Several computational algorithms and tools are available to track motile cells in time-lapse microscopy images. In contrast, there has only been limited effort towards the development of tools that take advantage of multi-channel microscopy data and facilitate integrative analysis of cell-motility. We have implemented algorithms for detecting, tracking, and analyzing cell motility from multi-channel time-lapse microscopy data. We have integrated these into a MATLAB-based toolset we call TIAM (Tool for Integrative Analysis of Motility). The cells are detected by a hybrid approach involving edge detection and Hough transforms from transmitted light images. Cells are tracked using a modified nearest-neighbor association followed by an optimization routine to join shorter segments. Cell positions are used to perform local segmentation for extracting features from transmitted light, reflection and fluorescence channels and associating them with cells and cell-tracks to facilitate integrative analysis. We found that TIAM accurately captures the motility behavior of T cells and performed better than DYNAMIK, Icy, Imaris, and Volocity in detecting and tracking motile T cells. Extraction of cell-associated features from reflection and fluorescence channels was also accurate with less than 10% median error in measurements. Finally, we obtained novel insights into T cell motility that were critically dependent on the unique capabilities of TIAM. We found that 1) the CD45RO subset of human CD8 T cells moved faster and exhibited an increased propensity to attach to the substratum during CCL21-driven chemokinesis when compared to the CD45RA subset; and 2) attachment area and arrest coefficient during antigen-induced motility of the CD45A subset is correlated with surface density of integrin LFA1 at the contact. PMID:25445324

  2. Satellite rainfall monitoring over Africa for food security, using multi-channel MSG data

    NASA Astrophysics Data System (ADS)

    Chadwick, R.; Grimes, D.; Saunders, R.; Blackmore, T.; Francis, P.

    2009-04-01

    Near real-time rainfall estimates are crucial in sub-Saharan Africa for a variety of humanitarian and agricultural purposes. However, for economic and infrastructural reasons, regularly reporting rain-gauges are sparse and precipitation radar networks extremely rare. Satellite rainfall estimates, particularly from geostationary satellites such as Meteosat Second Generation (MSG), present one method of filling this information gap, as they produce data at high temporal and spatial resolution. An algorithm has been developed to produce rainfall estimates for Africa from multi-channel MSG data. The algorithm is calibrated using precipitation radar data collected in Niamey, Niger as part of the African Monsoon Multidisciplinary Analyses (AMMA) project in 2006, and is based on an algorithm used operationally over Europe by the UK Met Office. Contingency tables are used to establish a statistical relationship between multi-channel MSG data and probability of rainfall at several different rain-rate magnitudes as sensed by the radar. Rain-rate estimates can then be produced at a variety of spatial and temporal scales, with MSG scan length (15 minutes) and pixel size (3-4km) as the lower limit. Results will be presented of a validation of this algorithm over the Sahel region of Africa. Rainfall estimates from this algorithm, processed for 2004, will be validated against gridded rain-gauge data at a 0.5 degree and 10 day timescale suitable for drought monitoring purposes. A comparison will also be made against rainfall estimates from the TAMSAT algorithm, which uses single channel IR data from MSG, and has been shown to perform well in the Sahel region.

  3. From Complex B1 Mapping to Local SAR Estimation for Human Brain MR Imaging Using Multi-channel Transceiver Coil at 7T

    PubMed Central

    Zhang, Xiaotong; Schmitter, Sebastian; Van de Moortel, Pierre-François; Liu, Jiaen

    2014-01-01

    Elevated Specific Absorption Rate (SAR) associated with increased main magnetic field strength remains as a major safety concern in ultra-high-field (UHF) Magnetic Resonance Imaging (MRI) applications. The calculation of local SAR requires the knowledge of the electric field induced by radiofrequency (RF) excitation, and the local electrical properties of tissues. Since electric field distribution cannot be directly mapped in conventional MR measurements, SAR estimation is usually performed using numerical model-based electromagnetic simulations which, however, are highly time consuming and cannot account for the specific anatomy and tissue properties of the subject undergoing a scan. In the present study, starting from the measurable RF magnetic fields (B1) in MRI, we conducted a series of mathematical deduction to estimate the local, voxel-wise and subject-specific SAR for each single coil element using a multi-channel transceiver array coil. We first evaluated the feasibility of this approach in numerical simulations including two different human head models. We further conducted experimental study in a physical phantom and in two human subjects at 7T using a multi-channel transceiver head coil. Accuracy of the results is discussed in the context of predicting local SAR in the human brain at UHF MRI using multi-channel RF transmission. PMID:23508259

  4. Spectrally shaped DP-16QAM super-channel transmission with multi-channel digital back-propagation.

    PubMed

    Maher, Robert; Xu, Tianhua; Galdino, Lidia; Sato, Masaki; Alvarado, Alex; Shi, Kai; Savory, Seb J; Thomsen, Benn C; Killey, Robert I; Bayvel, Polina

    2015-01-01

    The achievable transmission capacity of conventional optical fibre communication systems is limited by nonlinear distortions due to the Kerr effect and the difficulty in modulating the optical field to effectively use the available fibre bandwidth. In order to achieve a high information spectral density (ISD), while simultaneously maintaining transmission reach, multi-channel fibre nonlinearity compensation and spectrally efficient data encoding must be utilised. In this work, we use a single coherent super-receiver to simultaneously receive a DP-16QAM super-channel, consisting of seven spectrally shaped 10GBd sub-carriers spaced at the Nyquist frequency. Effective nonlinearity mitigation is achieved using multi-channel digital back-propagation (MC-DBP) and this technique is combined with an optimised forward error correction implementation to demonstrate a record gain in transmission reach of 85%; increasing the maximum transmission distance from 3190 km to 5890 km, with an ISD of 6.60 b/s/Hz. In addition, this report outlines for the first time, the sensitivity of MC-DBP gain to linear transmission line impairments and defines a trade-off between performance and complexity. PMID:25645457

  5. Spectrally Shaped DP-16QAM Super-Channel Transmission with Multi-Channel Digital Back-Propagation

    PubMed Central

    Maher, Robert; Xu, Tianhua; Galdino, Lidia; Sato, Masaki; Alvarado, Alex; Shi, Kai; Savory, Seb J.; Thomsen, Benn C.; Killey, Robert I.; Bayvel, Polina

    2015-01-01

    The achievable transmission capacity of conventional optical fibre communication systems is limited by nonlinear distortions due to the Kerr effect and the difficulty in modulating the optical field to effectively use the available fibre bandwidth. In order to achieve a high information spectral density (ISD), while simultaneously maintaining transmission reach, multi-channel fibre nonlinearity compensation and spectrally efficient data encoding must be utilised. In this work, we use a single coherent super-receiver to simultaneously receive a DP-16QAM super-channel, consisting of seven spectrally shaped 10GBd sub-carriers spaced at the Nyquist frequency. Effective nonlinearity mitigation is achieved using multi-channel digital back-propagation (MC-DBP) and this technique is combined with an optimised forward error correction implementation to demonstrate a record gain in transmission reach of 85%; increasing the maximum transmission distance from 3190 km to 5890 km, with an ISD of 6.60 b/s/Hz. In addition, this report outlines for the first time, the sensitivity of MC-DBP gain to linear transmission line impairments and defines a trade-off between performance and complexity. PMID:25645457

  6. Multi-channel amplitude analyzer for x-ray investigations

    NASA Astrophysics Data System (ADS)

    Karetnikov, M. D.; Klimov, A. I.; Zaitsev, V. I.

    2005-07-01

    The suggested device is implemented as one-module instrument including: a spectrometric amplifier providing superposition rejection, basic level restoration, track-and-hold functions, a precision ADC completed with the buffer memory; high-voltage power supply for X-ray detector; hardware interface with PC. All this resulted in a compact, functionally completed instrument for X-ray analysis. The device is a convenient instrument for X-ray fluorescent analysis, radiation diffraction studies, determination of element composition of a substance, customs and forensic expertise, medical diagnostics, testing of food products for presence of heavy elements, and other studies associated with X-ray applications. The functional diagram of the multi-channel amplitude analyzer is given in Fig. 1. The control circuit includes programmable logic device (PLD) EPM7128AETC100-lO manufactured by Altera Corporation, high performance C8051A021 processor by Cygnal Integrated Products and AS7C3256-12TC static memory by Cypress.

  7. FPGA-based multi-channel fluorescence lifetime analysis of Fourier multiplexed frequency-sweeping lifetime imaging

    PubMed Central

    Zhao, Ming; Li, Yu; Peng, Leilei

    2014-01-01

    We report a fast non-iterative lifetime data analysis method for the Fourier multiplexed frequency-sweeping confocal FLIM (Fm-FLIM) system [ Opt. Express22, 10221 ( 2014)24921725]. The new method, named R-method, allows fast multi-channel lifetime image analysis in the system’s FPGA data processing board. Experimental tests proved that the performance of the R-method is equivalent to that of single-exponential iterative fitting, and its sensitivity is well suited for time-lapse FLIM-FRET imaging of live cells, for example cyclic adenosine monophosphate (cAMP) level imaging with GFP-Epac-mCherry sensors. With the R-method and its FPGA implementation, multi-channel lifetime images can now be generated in real time on the multi-channel frequency-sweeping FLIM system, and live readout of FRET sensors can be performed during time-lapse imaging. PMID:25321778

  8. Dynamic multi-channel TMS with reconfigurable coil.

    PubMed

    Jiang, Ruoli; Jansen, Ben H; Sheth, Bhavin R; Chen, Ji

    2013-05-01

    Investigations of the causal involvement of particular brain areas and interconnections in behavior require an external stimulation system with reasonable spatio-temporal resolution. Current transcranial magnetic stimulation (TMS) technology is limited to stimulating a single brain area once in a given trial. Here, we present a feasibility study for a novel TMS system based on multi-channel reconfigurable coils. With this hardware, researchers will be able to stimulate multiple brain sites in any temporal order in a trial. The system employs a wire-mesh coil, constructed using x- and y-directional wires. By varying the current direction and/or strength on each wire, we can configure the proposed mesh-wire coil into a standard loop coil and figure-eight coil of varying size. This provides maximum flexibility to the experimenter in that the location and extent of stimulation on the brain surface can be modified depending on experimental requirement. Moreover, one can dynamically and automatically modify the site(s) of stimulation several times within the span of seconds. By pre-storing various sequences of excitation patterns inside a control unit, one can explore the effect of dynamic TMS on behavior, in associative learning, and as rehabilitative therapy. Here, we present a computer simulation and bench experiments that show the feasibility of the dynamically-reconfigurable coil. PMID:23193321

  9. Direct Hydrocarbon Detection Using Multi-channel Transient Electromagnetics

    NASA Astrophysics Data System (ADS)

    Hobbs, B. A.; Ziolkowski, A. M.; Wright, D. A.

    We present a transient electromagnetic method for the detection of hydrocarbons and for monitoring their movement within a reservoir. Replacement of brine by gas or oil can cause a change in electrical resistivity of a porous rock of as much as 4 orders of magnitude. Seismic methods on the other hand are generally poor at detecting fluid content because the fluid content of a media has only a slight effect on its acoustic impedance. The data presented in this paper were collected as part of two Multi-channel Transient ElectroMagnetic (MTEM) surveys carried out in 1994 and 1996 over an underground gas storage reservoir at St. Illiers la Ville in France. The reservoir is a 30% porosity sandstone anticline about 30m thick at a depth of around 700m. In the summer gas is pumped in and the gas-water contact falls; in the winter gas is extracted and the gas- water contact rises. The position of the contact is known from constant monitoring at over 40 wells. The surveys had two objectives: first, to attempt to detect the reservoir directly from the data; second, to detect the movement of the gas water contact be- tween the 2 survey times. A recent breakthrough in the understanding of the system has allowed both these objectives to be achieved.

  10. Investigating neuronal activity by SPYCODE multi-channel data analyzer.

    PubMed

    Bologna, Luca Leonardo; Pasquale, Valentina; Garofalo, Matteo; Gandolfo, Mauro; Baljon, Pieter Laurens; Maccione, Alessandro; Martinoia, Sergio; Chiappalone, Michela

    2010-08-01

    Multi-channel acquisition from neuronal networks, either in vivo or in vitro, is becoming a standard in modern neuroscience in order to infer how cell assemblies communicate. In spite of the large diffusion of micro-electrode-array-based systems, researchers usually find it difficult to manage the huge quantity of data routinely recorded during the experimental sessions. In fact, many of the available open-source toolboxes still lack two fundamental requirements for treating multi-channel recordings: (i) a rich repertoire of algorithms for extracting information both at a single channel and at the whole network level; (ii) the capability of autonomously repeating the same set of computational operations to 'multiple' recording streams (also from different experiments) and without a manual intervention. The software package we are proposing, named SPYCODE, was mainly developed to respond to the above constraints and generally to offer the scientific community a 'smart' tool for multi-channel data processing. PMID:20554151

  11. Superchannel transmission system based on multi-channel equalization.

    PubMed

    Zeng, Tao

    2013-06-17

    We proposed a new method for superchannel transmission based on the newly proposed multi-channel equalization technique. This method allows us to realize tight channel spacing (equal to the baud rate) without using frequency-locked lasers and complex spectral shaping techniques at the transmitter. The inter-channel interference originated from the tight channel spacing is removed at the receiver by joint equalization of multiple adjacent channels. When the channel spacing is equal to the baud rate, our simulation results show that, with conventional oversample ratio (2 samples per symbol), realistic laser frequency offset and laser linewidth, the proposed multi-channel-equalization based method can achieve better performance than the traditional method using spectral shaping plus single channel equalization, although at the expense of a moderate increase in DSP complexity. The paper also gives a simple method to process the data after conventional chromatic dispersion compensation, which enables subsequent multi-channel equalization for long-haul transmissions. PMID:23787667

  12. Quasiclassical theory of disordered multi-channel Majorana quantum wires

    NASA Astrophysics Data System (ADS)

    Neven, Patrick; Bagrets, Dmitry; Altland, Alexander

    2013-05-01

    Multi-channel spin-orbit quantum wires, when subjected to a magnetic field and proximity coupled to an s-wave superconductor, may support Majorana states. We study what happens to these systems in the presence of disorder. Inspired by the widely established theoretical methods of mesoscopic superconductivity, we develop á la Eilenberger a quasiclassical approach to topological nanowires valid in the limit of strong spin-orbit coupling. We find that the ‘Majorana number’ {\\cal M} , distinguishing between the state with Majorana fermions (symmetry class B) and no Majorana fermions (class D), is given by the product of two Pfaffians of gapped quasiclassical Green's functions fixed by the right and left terminals connected to the wire. A numerical solution of the Eilenberger equations reveals that the class D disordered quantum wires are prone to the formation of the zero-energy anomaly (class D impurity spectral peak) in the local density of states that shares the key features of the Majorana peak. In this way, we confirm the robustness of our previous conclusions (Bagrets and Altland 2012 Phys. Rev. Lett. 109 227005) on a more restrictive system setup. Generally speaking, we find that the quasiclassical approach provides a highly efficient means to address disordered class D superconductors both in the presence and in the absence of topological structures.

  13. Multi channel FM reflection profiler for buried pipeline surveying

    SciTech Connect

    Schock, S.G.; LeBlanc, L.R.

    1996-12-31

    A towed multi-channel FM acoustic reflection profiler has been developed for locating and generating images of buried objects. One significant application of this sonar is buried pipeline surveying. The multi-channel reflection profiler uses 16 line arrays mounted in a towed vehicle to determine the position and burial depth of an 18 inch steel pipe filled with concrete buried under 1.5 meters of sand. This sonar will allow a survey vessel to continuously track a buried pipeline providing a continuous record of pipe burial depth and position.

  14. A multi-channel readout electronics system for GEM and MICROMEGAS

    NASA Astrophysics Data System (ADS)

    Deng, Z.; Li, Y. L.; Gong, G. H.; Gong, H.; Luo, J.; Liu, Y. N.

    2009-11-01

    A multi-channel readout electronics system for GEM and MICROMEGAS has been developed. It consists of a front-end ASIC, a multi-channel ADC and a FPGA to sample the signal waveforms in real time. The gain of the front-end ASIC can be programmable from 1 mV/fC to 19 mV/fC and the output pulse width can be adjusted from 200 ns to 800 ns. The ENC is measured to be below 2000 e for Cin < 20 pF and below 5000 e for Cin < 60 pF. Detailed circuit performance and test results with detectors will be described in this paper.

  15. An Efficient VLSI Architecture for Multi-Channel Spike Sorting Using a Generalized Hebbian Algorithm

    PubMed Central

    Chen, Ying-Lun; Hwang, Wen-Jyi; Ke, Chi-En

    2015-01-01

    A novel VLSI architecture for multi-channel online spike sorting is presented in this paper. In the architecture, the spike detection is based on nonlinear energy operator (NEO), and the feature extraction is carried out by the generalized Hebbian algorithm (GHA). To lower the power consumption and area costs of the circuits, all of the channels share the same core for spike detection and feature extraction operations. Each channel has dedicated buffers for storing the detected spikes and the principal components of that channel. The proposed circuit also contains a clock gating system supplying the clock to only the buffers of channels currently using the computation core to further reduce the power consumption. The architecture has been implemented by an application-specific integrated circuit (ASIC) with 90-nm technology. Comparisons to the existing works show that the proposed architecture has lower power consumption and hardware area costs for real-time multi-channel spike detection and feature extraction. PMID:26287193

  16. Long-Term Drought Forecasting based on Climate Signals using Multi-Channel

    NASA Astrophysics Data System (ADS)

    Cui, H.; Singh, V. P.; Tang, Q.; Ge, Q.

    2015-12-01

    Drought is an insidious natural hazard, which may cause severe damage both in natural environment and human society. Timely drought forecasting enables civil protection authorities and public to take actions to reduce the risk of droughts. Thus drought forecasting plays an important role in setting out drought mitigation strategy. Analysis of the dominant oscillations of droughts and large-scale climate indices has shown that climate indices, such as the El Niño Southern Oscillation (ENSO), are significant indicators of drought occurrences in southern United States. It suggests that the climate indices may be used in drought forecasting at a long lead time. In this study, the multi-channel entropy spectral analysis (MCESA) was developed to incorporate the ENSO climate signals to entropy approach for long-term drought forecasting. To focus on the lack of surface water, drought was quantified by standardized streamflow index (SSI) in this study. SSI time series turned out to be stationary and highly autocorrelated, which showed significant 12-month periodicity. As a result, SSI was successfully forecasted using MCESA with ENSO as an indicator for lead times of 4-6 years. The drought forecasting was more reliable for the stations in humid areas than arid areas. Comparison from the retrospective drought forecasts with or without ENSO showed that inclusion of ENSO climate signals reduced the forecasting errors. The forecasts under El Nino (La Nina) condition reduced (increased) drought severity, making the forecasts more accurate.

  17. Partial flow compensation by transverse bypass configuration in multi-channel cryogenic compact heat exchanger

    NASA Astrophysics Data System (ADS)

    Jung, Jeheon; Hwang, Gyuwan; Baek, Seungwhan; Jeong, Sangkwon; Rowe, Andrew M.

    2012-01-01

    High-performance multi-channel heat exchangers are vulnerable to small defects such as ill-manufacture or contamination in flow channels. Even slight flow mal-distribution may result in drastic reduction of their thermal performance. In order to accommodate such performance reduction in multi-channel heat exchangers, transverse bypass structure among the channels of hot stream or cold stream is proposed. Since transverse bypass structure enables voluntary flow re-distribution among the channels, detrimental effect of flow defects can be partially reduced and flow mal-distribution can be locally relieved. The lower the flow resistance of transverse bypass is, the more substantial the flow re-distribution is and the larger its effect can be. Quantitative analysis and experimental verification on the effect of transverse bypass is carried out, and the results are presented in this paper.

  18. Development and demonstration of a multi-channel spheroidal focusing device for neutron beams

    NASA Astrophysics Data System (ADS)

    Hayashida, H.; Soyama, K.; Yamazaki, D.; Maruyama, R.; Yamamura, K.

    2014-07-01

    A multi-channel neutron focusing mirror is a compact device that can effectively enhance neutron intensity because the multi-channel structure can cover a large divergence of a neutron beam. In this study, we attempted to develop a compact multi-channel spheroidal (MS) neutron focusing device for two-dimensional focusing. A prototype of the MS mirror consists of three spheroidal mirrors of different diameters. The mirrors are fabricated through the copper plating method without supermirror coating and are aligned coaxially using ring-shaped spacers. The MS mirror was demonstrated at beam line 10 NOBORU port at J-PARC, which provides neutron beams with time-of-flight spectra. A gain factor of 6 in neutron intensity was obtained over wavelengths greater than 0.5 nm, and an imaging test with sample scanning could be performed with an exposure time of 10 s. A Gd-patterned standard sample was employed and a 2D image with a spatial resolution of 200 μm was successfully obtained.

  19. A New, Scalable and Low Cost Multi-Channel Monitoring System for Polymer Electrolyte Fuel Cells.

    PubMed

    Calderón, Antonio José; González, Isaías; Calderón, Manuel; Segura, Francisca; Andújar, José Manuel

    2016-01-01

    In this work a new, scalable and low cost multi-channel monitoring system for Polymer Electrolyte Fuel Cells (PEFCs) has been designed, constructed and experimentally validated. This developed monitoring system performs non-intrusive voltage measurement of each individual cell of a PEFC stack and it is scalable, in the sense that it is capable to carry out measurements in stacks from 1 to 120 cells (from watts to kilowatts). The developed system comprises two main subsystems: hardware devoted to data acquisition (DAQ) and software devoted to real-time monitoring. The DAQ subsystem is based on the low-cost open-source platform Arduino and the real-time monitoring subsystem has been developed using the high-level graphical language NI LabVIEW. Such integration can be considered a novelty in scientific literature for PEFC monitoring systems. An original amplifying and multiplexing board has been designed to increase the Arduino input port availability. Data storage and real-time monitoring have been performed with an easy-to-use interface. Graphical and numerical visualization allows a continuous tracking of cell voltage. Scalability, flexibility, easy-to-use, versatility and low cost are the main features of the proposed approach. The system is described and experimental results are presented. These results demonstrate its suitability to monitor the voltage in a PEFC at cell level. PMID:27005630

  20. A New, Scalable and Low Cost Multi-Channel Monitoring System for Polymer Electrolyte Fuel Cells

    PubMed Central

    Calderón, Antonio José; González, Isaías; Calderón, Manuel; Segura, Francisca; Andújar, José Manuel

    2016-01-01

    In this work a new, scalable and low cost multi-channel monitoring system for Polymer Electrolyte Fuel Cells (PEFCs) has been designed, constructed and experimentally validated. This developed monitoring system performs non-intrusive voltage measurement of each individual cell of a PEFC stack and it is scalable, in the sense that it is capable to carry out measurements in stacks from 1 to 120 cells (from watts to kilowatts). The developed system comprises two main subsystems: hardware devoted to data acquisition (DAQ) and software devoted to real-time monitoring. The DAQ subsystem is based on the low-cost open-source platform Arduino and the real-time monitoring subsystem has been developed using the high-level graphical language NI LabVIEW. Such integration can be considered a novelty in scientific literature for PEFC monitoring systems. An original amplifying and multiplexing board has been designed to increase the Arduino input port availability. Data storage and real-time monitoring have been performed with an easy-to-use interface. Graphical and numerical visualization allows a continuous tracking of cell voltage. Scalability, flexibility, easy-to-use, versatility and low cost are the main features of the proposed approach. The system is described and experimental results are presented. These results demonstrate its suitability to monitor the voltage in a PEFC at cell level. PMID:27005630

  1. Recent advances in Multi-Channel Algebraic Scattering

    SciTech Connect

    Karataglidis, S.; Fraser, P. R.; Amos, K.; Canton, L.; Pisent, G.; Svenne, J. P.; Knijff, D. van der

    2011-10-28

    For coupled-channel descriptions of low-energy nucleon-induced interactions involving nuclei with particle-unstable exited states, it is necessary to include the widths of the target states. How those widths may affect the elastic scattering cross sections is examined within the framework of the Multi-Channel Algebraic Scattering (MCAS) method.

  2. Instructional Design in Multi-Channel Learning System.

    ERIC Educational Resources Information Center

    Mukhopadhyay, Marmar; Parhar, Madhu

    2001-01-01

    Discusses instructional design and explains the multi-channel learning environment which was developed to allow the use of various media to provide alternative learning paths to accommodate differences in learning styles and media preferences. Highlights include taxonomies of learning; social aspects of learning; self-learning in distance…

  3. Design and application of multi-channel simultaneous detection system for well-earth potential

    NASA Astrophysics Data System (ADS)

    Lei, Shao; Jun, Lin; Wei, Jianrong; Sui, Yangyi; Wu, Ziyu

    2007-07-01

    Well-earth ERT (electrical resistance tomography) technology is an important geophysical exploration method which studies the location distribution of remaining oil. Based on virtual instrument technology, the author designs a set of multi-channel simultaneous detection system. It adopts multi-channel simultaneous sampling, bipolar and differential inputs, analog LPF (low pass filter), FIR digital filter, and linear accumulated digital averaging method or techniques to suppress electromagnetic noise and improve SNR (signal-to-noise ratio); uses digital signal process method to remove the overshoot, avoided huge errors and improved accuracy of measurement; adopts feedback compensative method to exclude the influence of SP(spontaneous potential) and cover a wide dynamic measurable scope; spectrum analysis method is used for judging all electrodes earthing situation correctly; the USB2.0 technique is used to solve the problem of bulky multi-channel data transmission to achieve high-speed data transmission between hardware and PC. The Liao He oilfield survey results show that the system is characterized with high efficiency, portable and strong antijiamming capability.

  4. Fast screening of rice knockout mutants by multi-channel microchip electrophoresis.

    PubMed

    Nan, He; Lee, Sang-Won; Kang, Seong Ho

    2012-08-15

    A multi-channel microchip electrophoresis (MC-ME) system with a laser-induced fluorescence detector was developed for the fast simultaneous detection of rice knockout mutants in genetically modified (GM) rice. In addition, three parallel separation channels were fabricated on a glass microchip to investigate the possibility of high-throughput screening of amplified-polymerase chain reaction products representing wild-type rice and mutants. The MC-ME system was developed to simultaneously record data on all channels using specifically designed electrodes for an even distribution of electric fields, an expanded laser beam for excitation, a 10× objective lens to capture emissions, and a charge coupled device camera for detection. Under a programmed electric field strength and a sieving gel matrix of 0.7% poly(ethylene oxide) (M(r)=8,000,000), T-DNA-inserted rice mutants, two standard wild-type rice lines, and six rice knockout mutants were analyzed within 4 min using three parallel channels on the microchip. Compared to conventional microchip electrophoresis, the MC-ME method is a valid and practical way to effectively analyze multiple samples in parallel for the identification of GM rice without any loss of resolving power or reproducibility. The MC-ME method was more than 15 times faster than traditional slab gel electrophoresis and proved to be a powerful tool for high-throughput screening of GM rice with high sensitivity, efficiency, and reproducibility. PMID:22841075

  5. Theory and simulation of multi-channel interference (MCI) widely tunable lasers.

    PubMed

    Chen, Quanan; Lu, Qiaoyin; Guo, Weihua

    2015-07-13

    A novel design of an InP-based monolithic widely tunable laser, multi-channel interference (MCI) laser, is proposed and presented for the first time. The device is comprised of a gain section, a common phase section and a multi-channel interference section. The multi-channel interference section contains a 1x8 splitter based on cascaded 1 × 2 multi-mode interferometers (MMIs) and eight arms with unequal length difference. The rear part of each arm is integrated with a one-port multi-mode interference reflector (MIR). Mode selection of the MCI laser is realized by the constructive interference of the lights reflected back by the eight arms. Through optimizing the arm length difference, a tuning range of more than 40 nm covering the whole C band, a threshold current around 11.5 mA and an side-mode-suppression-ratio (SMSR) up to 48 dB have been predicted for this widely tunable laser. Detailed design principle and numerical simulation results are presented. PMID:26191863

  6. The multi-channel cochlear implant and the relief of severe-to-profound deafness.

    PubMed

    Clark, Graeme

    2012-05-01

    This personal reflection outlines the discoveries at the University of Melbourne leading to the multi-channel cochlear implant, and its development industrially by Cochlear Limited. My earlier experimental electrophysiological research demonstrated temporal coding occurred for only low frequencies, i.e. below 200-500 pulses/second. I was able to confirm these findings perceptually in behaviourally conditioned animals. In addition, these studies showed that temporal discrimination occurred across spatial coding channels. These experimental results correlated with the later conscious experience for electrical stimulation in my implant patients. In addition, the mid-to-high frequencies were coded in part by place of stimulation using bipolar and monopolar stimulation to restrict current spread. Furthermore, place of stimulation had the qualities of sharpness and dullness, and was also experienced as vowels. Owing to the limitation in coding speech with a physiological model due to the overlap of electrical current leading to unpredictable variations in loudness, a speech coding strategy that extracted the most important speech features for transmission through an electro-neural 'bottle-neck' to the brain was explored. Our inaugural strategy, discovered in 1978, extracted the second formant for place of stimulation, voicing for rate of stimulation, and sound pressure for current level. This was the first coding strategy to provide open-set speech understanding, as shown by standard audiological tests, and it became the first clinically successful interface between the world and human consciousness. This strategy was improved with place coding for the third formant or high-frequency spectrum, and then the spectral maxima. In 1989, I operated on our first patient to receive a bilateral implant, and in 1990, the first with a bimodal processor. The psychophysics and speech perception for these showed that the stimuli from each side could be fused into a single image, and

  7. Content-Based Multi-Channel Network Coding Algorithm in the Millimeter-Wave Sensor Network.

    PubMed

    Lin, Kai; Wang, Di; Hu, Long

    2016-01-01

    With the development of wireless technology, the widespread use of 5G is already an irreversible trend, and millimeter-wave sensor networks are becoming more and more common. However, due to the high degree of complexity and bandwidth bottlenecks, the millimeter-wave sensor network still faces numerous problems. In this paper, we propose a novel content-based multi-channel network coding algorithm, which uses the functions of data fusion, multi-channel and network coding to improve the data transmission; the algorithm is referred to as content-based multi-channel network coding (CMNC). The CMNC algorithm provides a fusion-driven model based on the Dempster-Shafer (D-S) evidence theory to classify the sensor nodes into different classes according to the data content. By using the result of the classification, the CMNC algorithm also provides the channel assignment strategy and uses network coding to further improve the quality of data transmission in the millimeter-wave sensor network. Extensive simulations are carried out and compared to other methods. Our simulation results show that the proposed CMNC algorithm can effectively improve the quality of data transmission and has better performance than the compared methods. PMID:27376302

  8. Content-Based Multi-Channel Network Coding Algorithm in the Millimeter-Wave Sensor Network

    PubMed Central

    Lin, Kai; Wang, Di; Hu, Long

    2016-01-01

    With the development of wireless technology, the widespread use of 5G is already an irreversible trend, and millimeter-wave sensor networks are becoming more and more common. However, due to the high degree of complexity and bandwidth bottlenecks, the millimeter-wave sensor network still faces numerous problems. In this paper, we propose a novel content-based multi-channel network coding algorithm, which uses the functions of data fusion, multi-channel and network coding to improve the data transmission; the algorithm is referred to as content-based multi-channel network coding (CMNC). The CMNC algorithm provides a fusion-driven model based on the Dempster-Shafer (D-S) evidence theory to classify the sensor nodes into different classes according to the data content. By using the result of the classification, the CMNC algorithm also provides the channel assignment strategy and uses network coding to further improve the quality of data transmission in the millimeter-wave sensor network. Extensive simulations are carried out and compared to other methods. Our simulation results show that the proposed CMNC algorithm can effectively improve the quality of data transmission and has better performance than the compared methods. PMID:27376302

  9. A compact multi-channel fluorescence sensor with ambient light suppression

    NASA Astrophysics Data System (ADS)

    Egly, Dominik; Geörg, Daniel; Rädle, Matthias; Beuermann, Thomas

    2012-03-01

    A multi-channel fluorescence sensor has been developed for process monitoring and fluorescence diagnostics. It comprises a fiber-optic set-up with an immersion probe and an intensity-modulated high power ultraviolet light-emitting diode as a light source for fluorescence excitation. By applying an electronic lock-in procedure, fluorescence signals are selectively detectable at ambient light levels of 1000 000 times higher intensity. The sensor was designed to be compact, low cost and easily adaptable to a wide field of application. The set-up was used to simultaneously monitor three important metabolic fluorophores: NAD(P)H, flavins and porphyrins during the cultivation of a baker's yeast. Moreover, the accumulation and degradation kinetics of protoporphyrin IX induced by 5-aminolevulinic acid on the skin could be recorded by the sensor. The detection limit for protoporphyrin IX was determined to be 4 × 10-11 mol L-1. The linear signal amplification of the sensor and time courses of fluorescence signals monitored during yeast fermentations were validated using a commercial CCD spectrometer. The robust and flexible set-up of the fiber-optic measurement system promises easy implementation of this non-invasive analytical tool to fluorescence monitoring and diagnostics in R&D and production.

  10. Enabling Technology for the Exploration of the Arctic Ocean - Multi Channel Seismic Reflection data acquisition

    NASA Astrophysics Data System (ADS)

    Coakley, B.; Anderson, R.; Chayes, D. N.; Goemmer, S.; Oursler, M.

    2009-12-01

    Great advances in mapping the Arctic Ocean have recently been made through the relatively routine acquisition of multibeam data from icebreakers operating on various cruise. The USCGC Healy, the German icebreaker Polarstern, the Canadian icebreaker Amundsen and the Swedish icebreaker Oden all routinely collect multibeam data, even while in heavy ice pack. This increase in data has substantially improved our knowledge of the form of the Arctic Ocean seafloor. Unfortunately, it is not possible to routinely collect Multi Channel Seismic Reflection (MCS) data while underway in the ice pack. Our inability to simply collect these data restricts how we understand many of the features that segment the basin by depriving us of the historical information that can be obtained by imaging the stratigraphy. Without these data, scientific ocean drilling, the ultimate ground truth for Marine Geology, cannot be done. The technology and expertise to collect MCS must be adapted for the particular circumstances of the Arctic Ocean. While MCS data have been collected in the Arctic Ocean, the procedures have relied on icebreakers towing equipment. Since icebreakers follow the path of least resistance through the pack, data are acquired in locations that are not scientifically optimal and rarely in the relatively straight lines necessary for optimal processing. Towing in the ice pack is also difficult, inefficient and puts this equipment at substantial risk of crushing or loss. While icebreakers are one means to collect these data, it is time to conduct a systematic evaluation of the costs and benefits of different platforms for MCS data acquisition. This evaluation should enable collection of high-quality data set at selected locations to solve scientific problems. Substantial uncertainties exist about the relative capabilities, costs and limitations for acquisition of MCS data from various platforms in the Arctic Ocean. For example; - Is it possible to collect multi-channel seismic

  11. Multi-channel photon migration study in visible Chinese human muscle for optical detection of deep vein thrombosis

    NASA Astrophysics Data System (ADS)

    Sun, Yunlong; Li, Ting

    2016-03-01

    Deep vein thrombosis (DVT) always induced venous thrombosis. Most cases of venous thrombosis were induced by deep vein thrombosis (DVT), with high incidence rate of >60% in >60 years old people. Near-infrared spectroscopy (NIRS) were reported recently to be an intriguing and potential technique in detecting DVT in clinics. However, the photon transport is still unclear, which is crucial for the image reconstruction of the updated development called as NIRS-based DVT imager. Here we employed the Monte Carlo simulation software for 3D voxelized media (MCVM) and the Visible Chinese Human (VCH) model, which segmentation is finest in the world, to simulate multi-channel photon migration in calf muscle. And the image reconstruction of DVT hemodynamic distribution was achieved. This study, for the first time, provides the most realistic 3-D multichannel photon migration for NIRS study on DVT, and explored the image reconstruction for furtherly developing a NIRS-based DVT imager.

  12. Retrieving Land Surface Temperature from Hyperspectral Thermal Infrared Data Using a Multi-Channel Method

    PubMed Central

    Zhong, Xinke; Huo, Xing; Ren, Chao; Labed, Jelila; Li, Zhao-Liang

    2016-01-01

    Land Surface Temperature (LST) is a key parameter in climate systems. The methods for retrieving LST from hyperspectral thermal infrared data either require accurate atmospheric profile data or require thousands of continuous channels. We aim to retrieve LST for natural land surfaces from hyperspectral thermal infrared data using an adapted multi-channel method taking Land Surface Emissivity (LSE) properly into consideration. In the adapted method, LST can be retrieved by a linear function of 36 brightness temperatures at Top of Atmosphere (TOA) using channels where LSE has high values. We evaluated the adapted method using simulation data at nadir and satellite data near nadir. The Root Mean Square Error (RMSE) of the LST retrieved from the simulation data is 0.90 K. Compared with an LST product from the Spinning Enhanced Visible and Infrared Imager (SEVIRI) on Meteosat, the error in the LST retrieved from the Infared Atmospheric Sounding Interferometer (IASI) is approximately 1.6 K. The adapted method can be used for the near-real-time production of an LST product and to provide the physical method to simultaneously retrieve atmospheric profiles, LST, and LSE with a first-guess LST value. The limitations of the adapted method are that it requires the minimum LSE in the spectral interval of 800–950 cm−1 larger than 0.95 and it has not been extended for off-nadir measurements. PMID:27187408

  13. Retrieving Land Surface Temperature from Hyperspectral Thermal Infrared Data Using a Multi-Channel Method.

    PubMed

    Zhong, Xinke; Huo, Xing; Ren, Chao; Labed, Jelila; Li, Zhao-Liang

    2016-01-01

    Land Surface Temperature (LST) is a key parameter in climate systems. The methods for retrieving LST from hyperspectral thermal infrared data either require accurate atmospheric profile data or require thousands of continuous channels. We aim to retrieve LST for natural land surfaces from hyperspectral thermal infrared data using an adapted multi-channel method taking Land Surface Emissivity (LSE) properly into consideration. In the adapted method, LST can be retrieved by a linear function of 36 brightness temperatures at Top of Atmosphere (TOA) using channels where LSE has high values. We evaluated the adapted method using simulation data at nadir and satellite data near nadir. The Root Mean Square Error (RMSE) of the LST retrieved from the simulation data is 0.90 K. Compared with an LST product from the Spinning Enhanced Visible and Infrared Imager (SEVIRI) on Meteosat, the error in the LST retrieved from the Infared Atmospheric Sounding Interferometer (IASI) is approximately 1.6 K. The adapted method can be used for the near-real-time production of an LST product and to provide the physical method to simultaneously retrieve atmospheric profiles, LST, and LSE with a first-guess LST value. The limitations of the adapted method are that it requires the minimum LSE in the spectral interval of 800-950 cm(-1) larger than 0.95 and it has not been extended for off-nadir measurements. PMID:27187408

  14. Multi-channel medical imaging system

    DOEpatents

    Frangioni, John V.

    2016-05-03

    A medical imaging system provides simultaneous rendering of visible light and fluorescent images. The system may employ dyes in a small-molecule form that remain in a subject's blood stream for several minutes, allowing real-time imaging of the subject's circulatory system superimposed upon a conventional, visible light image of the subject. The system may provide an excitation light source to excite the fluorescent substance and a visible light source for general illumination within the same optical guide used to capture images. The system may be configured for use in open surgical procedures by providing an operating area that is closed to ambient light. The systems described herein provide two or more diagnostic imaging channels for capture of multiple, concurrent diagnostic images and may be used where a visible light image may be usefully supplemented by two or more images that are independently marked for functional interest.

  15. Multi-channel medical imaging system

    DOEpatents

    Frangioni, John V

    2013-12-31

    A medical imaging system provides simultaneous rendering of visible light and fluorescent images. The system may employ dyes in a small-molecule form that remain in the subject's blood stream for several minutes, allowing real-time imaging of the subject's circulatory system superimposed upon a conventional, visible light image of the subject. The system may provide an excitation light source to excite the fluorescent substance and a visible light source for general illumination within the same optical guide used to capture images. The system may be configured for use in open surgical procedures by providing an operating area that is closed to ambient light. The systems described herein provide two or more diagnostic imaging channels for capture of multiple, concurrent diagnostic images and may be used where a visible light image may be usefully supplemented by two or more images that are independently marked for functional interest.

  16. MULTI-CHANNEL ELECTRIC PULSE HEIGHT ANALYZER

    DOEpatents

    Gallagher, J.D. et al.

    1960-11-22

    An apparatus is given for converting binary information into coded decimal form comprising means, in combination with a binary adder, a live memory and a source of bigit pulses, for synchronizing the bigit pulses and the adder output pulses; a source of digit pulses synchronized with every fourth bigit pulse; means for generating a conversion pulse in response to the time coincidence of the adder output pulse and a digit pulse: means having a delay equal to two bigit pulse periods coupling the adder output with the memory; means for promptly impressing said conversion pulse on the input of said memory: and means having a delay equal to one bigit pulse period for again impressing the conversion pulse on the input of the memory whereby a fourth bigit adder pulse results in the insertion into the memory of second, third and fourth bigits.

  17. Optical-network-connected multi-channel 96-GHz-band distributed radar system

    NASA Astrophysics Data System (ADS)

    Kanno, Atsushi; Kuri, Toshiaki; Kawanishi, Tetsuya

    2015-05-01

    The millimeter-wave (MMW) radar is a promising candidate for high-precision imaging because of its short wavelength and broad range of available bandwidths. In particular in the frequency range of 92-100 GHz, which is regulated for radiolocation, an atmospheric attenuation coefficient less than 1 dB/km limits the imaging range. Therefore, a combination of MMW radar and distributed antenna system directly connected to optical fiber networks can realize both high-precision imaging and large-area surveillance. In this paper, we demonstrate a multi-channel MMW frequency-modulated continuous-wave distributed radar system connected to an analog radio-over-fiber network.

  18. Multi-channel optical pyrometer for sub-nanosecond temperature measurements at NDCX-I/II

    SciTech Connect

    Ni, P.A.; Bieniosek, F.M.; Waldron, W.L.

    2011-04-13

    We present a detailed technical description of a fast multi-channel pyrometer designed for warm-dense-matter (WDM) experiments with intense heavy ion beams at the neutralized-drift-compression-experiment linear accelerator (NDCX-I/II) at Lawrence Berkeley National Laboratory (LBNL). The unique features of the described instrument are its sub-nanosecond temporal resolution (100 ps rise-time) and a broad range, 1,500 K - 12,000 K of measurable brightness temperatures in the visible and near-infrared regions of the spectrum. The working scheme, calibration procedure, experimental data obtained with the pyrometer and future applications are presented.

  19. Advances in 3D soil mapping and water content estimation using multi-channel ground-penetrating radar

    NASA Astrophysics Data System (ADS)

    Moysey, S. M.

    2011-12-01

    Multi-channel ground-penetrating radar systems have recently become widely available, thereby opening new possibilities for shallow imaging of the subsurface. One advantage of these systems is that they can significantly reduce survey times by simultaneously collecting multiple lines of GPR reflection data. As a result, it is becoming more practical to complete 3D surveys - particularly in situations where the subsurface undergoes rapid changes, e.g., when monitoring infiltration and redistribution of water in soils. While 3D and 4D surveys can provide a degree of clarity that significantly improves interpretation of the subsurface, an even more powerful feature of the new multi-channel systems for hydrologists is their ability to collect data using multiple antenna offsets. Central mid-point (CMP) surveys have been widely used to estimate radar wave velocities, which can be related to water contents, by sequentially increasing the distance, i.e., offset, between the source and receiver antennas. This process is highly labor intensive using single-channel systems and therefore such surveys are often only performed at a few locations at any given site. In contrast, with multi-channel GPR systems it is possible to physically arrange an array of antennas at different offsets, such that a CMP-style survey is performed at every point along a radar transect. It is then possible to process this data to obtain detailed maps of wave velocity with a horizontal resolution on the order of centimeters. In this talk I review concepts underlying multi-channel GPR imaging with an emphasis on multi-offset profiling for water content estimation. Numerical simulations are used to provide examples that illustrate situations where multi-offset GPR profiling is likely to be successful, with an emphasis on considering how issues like noise, soil heterogeneity, vertical variations in water content and weak reflection returns affect algorithms for automated analysis of the data. Overall

  20. A Novel GBM Saliency Detection Model Using Multi-Channel MRI

    PubMed Central

    Banerjee, Subhashis; Mitra, Sushmita; Shankar, B. Uma; Hayashi, Yoichi

    2016-01-01

    The automatic computerized detection of regions of interest (ROI) is an important step in the process of medical image processing and analysis. The reasons are many, and include an increasing amount of available medical imaging data, existence of inter-observer and inter-scanner variability, and to improve the accuracy in automatic detection in order to assist doctors in diagnosing faster and on time. A novel algorithm, based on visual saliency, is developed here for the identification of tumor regions from MR images of the brain. The GBM saliency detection model is designed by taking cue from the concept of visual saliency in natural scenes. A visually salient region is typically rare in an image, and contains highly discriminating information, with attention getting immediately focused upon it. Although color is typically considered as the most important feature in a bottom-up saliency detection model, we circumvent this issue in the inherently gray scale MR framework. We develop a novel pseudo-coloring scheme, based on the three MRI sequences, viz. FLAIR, T2 and T1C (contrast enhanced with Gadolinium). A bottom-up strategy, based on a new pseudo-color distance and spatial distance between image patches, is defined for highlighting the salient regions in the image. This multi-channel representation of the image and saliency detection model help in automatically and quickly isolating the tumor region, for subsequent delineation, as is necessary in medical diagnosis. The effectiveness of the proposed model is evaluated on MRI of 80 subjects from the BRATS database in terms of the saliency map values. Using ground truth of the tumor regions for both high- and low- grade gliomas, the results are compared with four highly referred saliency detection models from literature. In all cases the AUC scores from the ROC analysis are found to be more than 0.999 ± 0.001 over different tumor grades, sizes and positions. PMID:26752735

  1. Multi-channel analysis of passive surface waves based on cross-correlations

    NASA Astrophysics Data System (ADS)

    Cheng, F.; Xia, J.; Xu, Z.; Hu, Y.

    2015-12-01

    Traditional active seismic survey can no longer be properly applied in highly populated urban areas due to restrictions in modern civilian life styles. Passive seismic methods, however, have gained much more attention from the engineering geophysics community because of their environmental friendly and deeper investigation depth. Due to extracting signal from noise has never been as comfortable as that in active seismic survey, how to make it more efficiently and accurately has been emphasized. We propose a multi-channel analysis of passive surface waves (MAPW) based on long noise sequences cross-correlations to meet the demand for increasing investigation depth by acquiring surface-wave data at a relative low-frequency range (1 Hz ≤ f ≤ 10 Hz) in urban areas. We utilize seismic interferometry to produce common virtual source gathers from one-hour-long noise records and do dispersion measurements by using the classic passive multi-channel analysis of surface waves (PMASW). We used synthetic tests to demonstrate the advantages of MAPW for various noise distributions. Results show that our method has the superiority of maximizing the analysis accuracy. Finally, we used two field data applications to demonstrate the advantages of our MAPW over the classic PMASW on isolating azimuth of the predominant noise sources and the effectivity of combined survey of active multi-channel analysis of surface waves (MASW) and MAPW. We suggest, for the field operation using MAPW, that a parallel receiver line which is close to a main road or river, if any, with one or two hours noise observation will be an effective means for an unbiased dispersion image. Keywords: passive seismic method, MAPW, MASW, cross-correlation, directional noise source, spatial-aliasing effects, inversion

  2. Multi-Channel Adjustable DC Power Supply with Single Transformer Based on Spectral Separation

    NASA Astrophysics Data System (ADS)

    Benfeng, Zhang; Huafeng, Li; Sunan, Li

    2014-01-01

    To meet the need of multi-channel DC power supply to activate multiple macro fiber composite (MFC) material simultaneously, a novel multi-channel adjustable DC supply using single-input single-output transformer based on spectral separation is proposed. A hybrid signal containing multiple frequency bands is boosted to obtain a high-voltage signal without bands change. Several frequency selection circuits are then used to separate individual signals in different frequency band from the high-voltage signal. Finally, these signals are rectified and filtered respectively to obtain multiple channel DC voltages. The feasibility of the proposed scheme is analyzed theoretically and verified by simulation. The hybrid signal containing multiple frequency bands is constructed by MCU (Micro Control Unit) and boosted using push-pull boost circuit. Low-pass, band-pass and high-pass frequency selection circuits are used to obtain the individual high-voltage signal in different frequency bands, and the amplitude frequency response characteristics of these filters are simulated using PSpice. Experimental results prove that each part of the scheme runs reliable and the output is stable and adjustable.

  3. Multi-channel fiber photometry for population neuronal activity recording

    PubMed Central

    Guo, Qingchun; Zhou, Jingfeng; Feng, Qiru; Lin, Rui; Gong, Hui; Luo, Qingming; Zeng, Shaoqun; Luo, Minmin; Fu, Ling

    2015-01-01

    Fiber photometry has become increasingly popular among neuroscientists as a convenient tool for the recording of genetically defined neuronal population in behaving animals. Here, we report the development of the multi-channel fiber photometry system to simultaneously monitor neural activities in several brain areas of an animal or in different animals. In this system, a galvano-mirror modulates and cyclically couples the excitation light to individual multimode optical fiber bundles. A single photodetector collects excited light and the configuration of fiber bundle assembly and the scanner determines the total channel number. We demonstrated that the system exhibited negligible crosstalk between channels and optical signals could be sampled simultaneously with a sample rate of at least 100 Hz for each channel, which is sufficient for recording calcium signals. Using this system, we successfully recorded GCaMP6 fluorescent signals from the bilateral barrel cortices of a head-restrained mouse in a dual-channel mode, and the orbitofrontal cortices of multiple freely moving mice in a triple-channel mode. The multi-channel fiber photometry system would be a valuable tool for simultaneous recordings of population activities in different brain areas of a given animal and different interacting individuals. PMID:26504642

  4. A duple watermarking strategy for multi-channel quantum images

    NASA Astrophysics Data System (ADS)

    Yan, Fei; Iliyasu, Abdullah M.; Sun, Bo; Venegas-Andraca, Salvador E.; Dong, Fangyan; Hirota, Kaoru

    2015-05-01

    Utilizing a stockpile of efficient transformations consisting of channel of interest, channel swapping, and quantum Fourier transforms, a duple watermarking strategy on multi-channel quantum images is proposed. It embeds the watermark image both into the spatial domain and the frequency domain of the multi-channel quantum carrier image, while also providing a quantum measurement-based algorithm to generate an unknown key that is used to protect the color information, which accompanies another key that is mainly used to scramble the spatial content of the watermark image in order to further safeguard the copyright of the carrier image. Simulation-based experiments using a watermark logo and nine building images as watermark image and carrier images, respectively, offer a duple protection for the copyright of carrier images in terms of the visible quality of the watermarked images. The proposed stratagem advances available literature in the quantum watermarking research field and sets the stage for the applications aimed at quantum data protection.

  5. A wireless multi-channel bioimpedance measurement system for personalized healthcare and lifestyle.

    PubMed

    Ramos, Javier; Ausín, José Luis; Lorido, Antonio Manuel; Redondo, Francisco; Duque-Carrillo, Juan Francisco

    2013-01-01

    Miniaturized, noninvasive, wearable sensors constitute a fundamental prerequisite for pervasive, predictive, and preventive healthcare systems. In this sense, this paper presents the design, realization, and evaluation of a wireless multi-channel measurement system based on a cost-effective high-performance integrated circuit for electrical bioimpedance (EBI) measurements in the frequency range from 1 kHz to 1 MHz. The resulting on-chip spectrometer provides high measuring EBI capabilities and together with a low-cost, commercially available radio frequency transceiver device. It provides reliable wireless communication, constitutes the basic node to build EBI wireless sensor networks (EBI-WSNs). The proposed EBI-WSN behaves as a high-performance wireless multi-channel EBI spectrometer, where the number of channels is completely scalable and independently configurable to satisfy specific measurement requirements of each individual. A prototype of the EBI node leads to a very small printed circuit board of approximately 8 cm2 including chip-antenna, which can operate several years on one 3-V coin cell battery and make it suitable for long-term preventive healthcare monitoring. PMID:23739358

  6. Multi-channel seismic reflection measurements in the Eurasian Basin, Arctic Ocean, from U.S. ice station Fram-IV

    NASA Astrophysics Data System (ADS)

    Kristoffersen, Yngve; Husebye, Eystein S.

    1985-04-01

    We present the first multi-channel seismic reflection data ever collected from the Eurasian Basin of the Arctic Ocean. The 200 km data set was acquired by a 20 channel sonobuoy array deployed at U.S. ice drift station FRAM-IV and operated for 34 days about 370 km north of Svalbard in April-May 1982. Cross array drift and ice floe rotation which may constitute the most serious obstacle to the advantage of multi-channel data acquisition did only occur to a minor degree during the experiment and render most of the data set suitable for processing using common mid-point binning. A 0.7-1.4 s (two-way traveltime) thick sedimentary section has been deposited over oceanic crust of mid-Oligocene age below the Barents Abyssal Plain. In the deepest part, sediments are infilling topographic lows which indicate predominantly turbidite deposition. Erosional truncations are only locally present in the central part of the section. Conformable bedforms deposited over gentle basement highs indicate a relatively stable bottom current regime since mid-Oligocene time. Thus the establishment of a deep water connection between the Arctic Ocean and lower latitude water masses appear to have had only minor effect on Eurasian Basin bottom current circulation. Extensive submarine slide scars on the north slope of Yermak Plateau show that mass waste have been a sediment source to the Barents Abyssal Plain.

  7. Multi-channel transimpedance measurement of a planar electromagnetic sensor array

    NASA Astrophysics Data System (ADS)

    Chen, Dixiang; Xie, Ruifang; Zhou, Weihong; Hu, Hengjiang; Pan, Mengchun

    2015-02-01

    Planar electromagnetic sensor arrays have advantages such as nice coherence, fast response speed and high sensitivity, which can be used for micro damage inspection of crucial parts in equipment, and the key point in improving the inspection performance is to achieve a precise measurement of multi-channel transimpedances (the inductive voltages divided by the exciting current of the sensor). The principle and characteristics of planar electromagnetic sensor arrays are introduced in this paper, and a digital lock-in impedance measurement algorithm was investigated, with which the interference and noise in inductive voltage signals can be restrained effectively and the amplitude and phase of the transimpedance can be obtained with good repeatability. An eight channel impedance measurement system was established based on a field programmable gate array and utilized to inspect the micro damage in metal materials, and the experimental data were analyzed. The experimental results show that the impedance measurement has excellent repeatability when the sensor array is placed in air, and the maximum measurement error of the complete transimpedance measurement system is lower than 10%. A micro crack with a size of 1 mm (length) × 0.1 mm (width) × 1 mm (depth) can be detected through the measurement of multi-channel transimpedance in the planar electromagnetic sensor array.

  8. Generation and detection of broadband multi-channel orbital angular momentum by micrometer-scale meta-reflectarray.

    PubMed

    Liu, Jinpeng; Min, Changjun; Lei, Ting; Du, Luping; Yuan, Yangsheng; Wei, Shibiao; Wang, Yiping; Yuan, X-C

    2016-01-11

    We theoretically demonstrate the generation and detection of broadband multi-channel Orbital Angular Momentum(OAM) by a micrometer-scale meta-reflectarray. The meta-reflectarray composed of patterned silicon bars on a silver ground plane can be designed to realize phase modulation and work as chip-level OAM devices. Compared to traditional methods of OAM generation and detection, our approach shows superiorities of very compact structure size, broadband working wavelength (1250-1750 nm), high diffraction efficiency (~70%), simultaneously handling multiplex OAMs, and tunable reflection angle (0-45°). These fascinating advantages provides great potential applications in photonic integrated devices and systems for high-capacity and multi-channel OAM communication. PMID:26832252

  9. Ground moving target indication via multi-channel airborne SAR

    NASA Astrophysics Data System (ADS)

    Vu, Duc; Guo, Bin; Xu, Luzhou; Li, Jian

    2011-06-01

    We consider moving target detection and velocity estimation for multi-channel synthetic aperture radar (SAR) based ground moving target indication (GMTI). Via forming velocity versus cross-range images, we show that small moving targets can be detected even in the presence of strong stationary ground clutter. Furthermore, the velocities of the moving targets can be estimated, and the misplaced moving targets can be placed back to their original locations based on the estimated velocities. An iterative adaptive approach (IAA), which is robust and user parameter free, is used to form velocity versus cross-range images for each range bin of interest. Moreover, we discuss calibration techniques to combat near-field coupling problems encountered in practical systems. Furthermore, we present a sparse signal recovery approach for stationary clutter cancellation. We conclude by demonstrating the effectiveness of our approaches by using the Air Force Research Laboratory (AFRL) publicly-released Gotcha airborne SAR based GMTI data set.

  10. Multi-channel detector readout method and integrated circuit

    DOEpatents

    Moses, William W.; Beuville, Eric; Pedrali-Noy, Marzio

    2004-05-18

    An integrated circuit which provides multi-channel detector readout from a detector array. The circuit receives multiple signals from the elements of a detector array and compares the sampled amplitudes of these signals against a noise-floor threshold and against one another. A digital signal is generated which corresponds to the location of the highest of these signal amplitudes which exceeds the noise floor threshold. The digital signal is received by a multiplexing circuit which outputs an analog signal corresponding the highest of the input signal amplitudes. In addition a digital control section provides for programmatic control of the multiplexer circuit, amplifier gain, amplifier reset, masking selection, and test circuit functionality on each input thereof.

  11. Multi-channel detector readout method and integrated circuit

    DOEpatents

    Moses, William W.; Beuville, Eric; Pedrali-Noy, Marzio

    2006-12-12

    An integrated circuit which provides multi-channel detector readout from a detector array. The circuit receives multiple signals from the elements of a detector array and compares the sampled amplitudes of these signals against a noise-floor threshold and against one another. A digital signal is generated which corresponds to the location of the highest of these signal amplitudes which exceeds the noise floor threshold. The digital signal is received by a multiplexing circuit which outputs an analog signal corresponding the highest of the input signal amplitudes. In addition a digital control section provides for programmatic control of the multiplexer circuit, amplifier gain, amplifier reset, masking selection, and test circuit functionality on each input thereof.

  12. A calibration method of the multi-channel imaging lidar

    NASA Astrophysics Data System (ADS)

    Xu, Weiming; Liu, Jun; Shu, Rong

    2014-06-01

    We design a kind of imaging LiDAR with sixteen channels, which consists of a fiber laser source, dual scanning galvanometers, range measurement circuits and information processing circuits etc. The image LiDAR provides sixteen range measurements for one laser shot and the distance accuracy of each channel is about 4cm. This paper provides a calibrate method to correct point cloud images captured with the multi-channel LiDAR. The method needs to construct different slanted planes to cover the imaging field, and establish precise plane equations in the known ground coordinates, then fit planes with point clouds data and calculate correction parameters of all channels through the error model. The image accuracy is better than 5cm processed by this calibration method.

  13. Improving virtual channel discrimination in a multi-channel context.

    PubMed

    Srinivasan, Arthi G; Shannon, Robert V; Landsberger, David M

    2012-04-01

    Improving spectral resolution in cochlear implants is key to improving performance in difficult listening conditions (e.g. speech in noise, music, etc.). Current focusing might reduce channel interaction, thereby increasing spectral resolution. Previous studies have shown that combining current steering and current focusing reduces spread of excitation and improves virtual channel discrimination in a single-channel context. It is unclear whether the single-channel benefits from current focusing extend to a multi-channel context, in which the physical and perceptual interference of multiple stimulated channels might overwhelm the benefits of improved spectral resolution. In this study, signal discrimination was measured with and without current focusing, in the presence of competing stimuli on nearby electrodes. Results showed that signal discrimination was consistently better with current focusing than without, regardless of the amplitude of the competing stimuli. Therefore, combining current steering and current focusing may provide more effective spectral cues than are currently available. PMID:22616092

  14. Analysis of motion disambiguation using multi-channel circular SAR

    NASA Astrophysics Data System (ADS)

    Fasih, Ahmed R.; Rossler, Carl W.; Ash, Joshua N.; Moses, Randolph L.

    2010-04-01

    Combining moving target indication (MTI) radar with synthetic aperture radar (SAR) is of great interest to radar specialists, in terms of improving multiple-target tracking in large, urban scenes. A major obstacle to such a merger are ambiguities induced by mution. Using statistical bounds we quantify the improvement of moving target localization with multi-channel SAR over single-channel SAR and the more traditional MTI technique of displaced phase center array (DPCA) processing. We show that the potential for substantial improvements in localization performance is borne out by practical estimators based on sparse reconstruction algorithms, whose performance approach statistical bounds, even under clutter. We also outline a parallelization scheme for the nonquadratic regularized sparse reconstruction technique to utilize clusters for processing large datasets.

  15. Multi-channel access technology based on wavelength division multiplexing in wireless UV communication mesh network

    NASA Astrophysics Data System (ADS)

    Zhao, Tai-fei; Zhang, Ai-li; Xue, Rong-li

    2013-05-01

    In this paper, the multi-channel access technology of wavelength division multiplexing (WDM) in the wireless ultraviolet (UV) scattering communication is studied. A multi-interface and multi-channel device is deployed in each UV transceiver node. The band-pass filter is configured in the receiving node so as to realize the multi-channel access by use of the UV WDM technology. Both the UV communication node model and the UV channel model are established. Three types of UV no-line-of-sight (NLOS) multi-channel communications are simulated in the mesh topologies with NS2. The results show that the UV multi-channel access technology can increase network throughput effectively with using WDM.

  16. An Efficient, Highly Flexible Multi-Channel Digital Downconverter Architecture

    NASA Technical Reports Server (NTRS)

    Goodhart, Charles E.; Soriano, Melissa A.; Navarro, Robert; Trinh, Joseph T.; Sigman, Elliott H.

    2013-01-01

    In this innovation, a digital downconverter has been created that produces a large (16 or greater) number of output channels of smaller bandwidths. Additionally, this design has the flexibility to tune each channel independently to anywhere in the input bandwidth to cover a wide range of output bandwidths (from 32 MHz down to 1 kHz). Both the flexibility in channel frequency selection and the more than four orders of magnitude range in output bandwidths (decimation rates from 32 to 640,000) presented significant challenges to be solved. The solution involved breaking the digital downconversion process into a two-stage process. The first stage is a 2 oversampled filter bank that divides the whole input bandwidth as a real input signal into seven overlapping, contiguous channels represented with complex samples. Using the symmetry of the sine and cosine functions in a similar way to that of an FFT (fast Fourier transform), this downconversion is very efficient and gives seven channels fixed in frequency. An arbitrary number of smaller bandwidth channels can be formed from second-stage downconverters placed after the first stage of downconversion. Because of the overlapping of the first stage, there is no gap in coverage of the entire input bandwidth. The input to any of the second-stage downconverting channels has a multiplexer that chooses one of the seven wideband channels from the first stage. These second-stage downconverters take up fewer resources because they operate at lower bandwidths than doing the entire downconversion process from the input bandwidth for each independent channel. These second-stage downconverters are each independent with fine frequency control tuning, providing extreme flexibility in positioning the center frequency of a downconverted channel. Finally, these second-stage downconverters have flexible decimation factors over four orders of magnitude The algorithm was developed to run in an FPGA (field programmable gate array) at input data sampling rates of up to 1,280 MHz. The current implementation takes a 1,280-MHz real input, and first breaks it up into seven 160-MHz complex channels, each spaced 80 MHz apart. The eighth channel at baseband was not required for this implementation, and led to more optimization. Afterwards, 16 second stage narrow band channels with independently tunable center frequencies and bandwidth settings are implemented A future implementation in a larger Xilinx FPGA will hold up to 32 independent second-stage channels.

  17. Non-cross talk multi-channel photomultiplier using guided electron multipliers

    DOEpatents

    Gomez, J.; Majewski, S.; Weisenberger, A.G.

    1995-09-26

    An improved multi-channel electron multiplier is provided that exhibits zero cross-talk and high rate operation. Resistive material input and output masks are employed to control divergence of electrons. Electron multiplication takes place in closed channels. Several embodiments are provided for these channels including a continuous resistive emissive multiplier and a discrete resistive multiplier with discrete dynode chains interspaced with resistive layers-masks. Both basic embodiments provide high gain multiplication of electrons without accumulating surface charges while containing electrons to their proper channels to eliminate cross-talk. The invention can be for example applied to improve the performance of ion mass spectrometers, positron emission tomography devices, in DNA sequencing and other beta radiography applications and in many applications in particle physics. 28 figs.

  18. Non cross talk multi-channel photomultiplier using guided electron multipliers

    DOEpatents

    Gomez, Javier; Majewski, Stanislaw; Weisenberger, Andrew G.

    1995-01-01

    An improved multi-channel electron multiplier is provided that exhibits zero cross-talk and high rate operation. Resistive material input and output masks are employed to control divergence of electrons. Electron multiplication takes place in closed channels. Several embodiments are provided for these channels including a continuous resistive emissive multiplier and a discrete resistive multiplier with discrete dynode chains interspaced with resistive layers-masks. Both basic embodiments provide high gain multiplication of electrons without accumulating surface charges while containing electrons to their proper channels to eliminate cross-talk. The invention can be for example applied to improve the performance of ion mass spectrometers, positron emission tomography devices, in DNA sequencing and other beta radiography applications and in many applications in particle physics.

  19. Multi-channel PMMA microfluidic biosensor with integrated IDUAs for electrochemical detection

    PubMed Central

    Wongkaew, Nongnoot; He, Peng; Kurth, Vanessa; Surareungchai, Werasak; Baeumner, Antje J.

    2013-01-01

    A novel multi-channel poly(methyl methacrylate) (PMMA) microfluidic biosensor with interdigitated ultramicroelectrode arrays (IDUAs) for electrochemical detection was developed. The focus of the development was a simple fabrication procedure and the realization of a reliable large IDUA that can provide detection simultaneously to several microchannels. As proof of concept, five microchannels are positioned over a large single IDUA where the channels are parallel with the length of electrode finger. The IDUAs were fabricated on the PMMA cover piece and bonded to a PMMA substrate containing the microfluidic channels using UV/ozone-assisted thermal bonding. Conditions of device fabrication were optimized realizing a rugged large IDUA within a bonded PMMA device. Gold adhesion to the PMMA, protective coatings and pressure during bonding were optimized. Its electrochemical performance was studied using amperometric detection of potassium ferri and ferro hexacyanide. Cumulative signals within the same chip showed very good linearity over a range of 0 - 38 μM (R2 = 0.98) and a limit of detection of 3.48 μM. The bonding of the device was optimized so that no cross-talk between the channels was observed which otherwise would have resulted in unreliable electrochemical responses. The highly reproducible signals achieved were comparable to those obtained with separate single-channel devices. Subsequently, the multi-channel microfluidic chip was applied to a model bioanalytical detection strategy, i.e. the quantification of specific nucleic acid sequences using a sandwich approach. Here probe-coated paramagnetic beads and probe-tagged liposomes entrapping ferri/ferro hexacyanide as the redox marker were used to bind to a single stranded DNA sequence. Flow rates of the non-ionic detergent n-octyl-β-D-glucopyranoside (OG) for liposome lysis were optimized and the detection of the target sequences was carried out coulometrically within 250 s and with a limit of detection of 12

  20. Design and performance of a fiber array coupled multi-channel photon counting, 3D imaging, airborne lidar system

    NASA Astrophysics Data System (ADS)

    Huang, Genghua; Shu, Rong; Hou, Libing; Li, Ming

    2014-06-01

    Photon counting lidar has an ultra-high sensitivity which can be hundreds even thousands of times higher than the linear detection lidar. It can significantly increase the system's capability of detection rang and imaging density, saving size and power consumings in airborne or space-borne applications. Based on Geiger-mode Si avalanche photodiodes (Si-APD), a prototype photon counting lidar which used 8 APDs coupled with a 1×8-pixel fiber array has been made in June, 2011. The experiments with static objects showed that the photon counting lidar could operate in strong solar background with 0.04 receiving photoelectrons on average. Limited by less counting times in moving platforms, the probability of detection and the 3D imaging density would be lower than that in static platforms. In this paper, a latest fiber array coupled multi-channel photon counting, 3D imaging, airborne lidar system is introduced. The correlation range receiver algorithm of photon counting 3D imaging is improved for airborne signal photon events extraction and noise filter. The 3D imaging experiments in the helicopter shows that the false alarm rate is less than 6×10-7, and the correct rate is better than 99.9% with 4 received photoelectrons and 0.7MHz system noise on average.

  1. Multi-channel quantum dragons from rectangular nanotubes with even-odd structure

    NASA Astrophysics Data System (ADS)

    Inkoom, Godfred; Novotny, Mark

    Recently, a large class of nanostructures called quantum dragons have been discovered theoretically. Quantum dragons are nanostuctures with correlated disorder but have an electron transmission probability  (E) =1 for all energies E when connected to idealized leads. Hence for a single channel, the electrical conductance for a two-probe measurement should give the quantum of conductance Go =2e2/h . The time independent Schrödinger equation for the single band tight binding model is solved exactly to obtain  (E) . We have generalized the matrix method and the mapping methods of in order to study multi-channel quantum dragons for rectangular nanotubes with even-odd structure. The studies may be relevant for experimental rectangular nanotubes, such as MgO, copper phthalocyanine or some types of graphyne.. Supported in part by NSF Grant DMR-1206233.

  2. [Optical multi-channel detection and analysis on solar ultra-violet irradiance spectrum].

    PubMed

    Zhao, Xiao-yan; He, Jie; Zuo, Hao-yi; Liang, Hui-min; Yang, Jing-guo

    2007-05-01

    The present paper reports a new type of ultraviolet CCD optical multi-channel analyzer and its application to detecting solar ultraviolet irradiance spectrum. Spectral detecting range of 200-1 100 nm, spectral resolution of 0.1 nm and detecting sensitivity of 0.02 lx were reached in this instrument. The solar spectra of UVB and UVA were measured in real time in Chengdu area. The measurement results have good correlation with the detection using normal solar ultraviolet irradiance detector. Primary analysis on the detection results of solar spectra in UVB and UVA indicated that in the morning and in the afternoon the irradiance of solar ultraviolet is smaller than that at noon, and reverse correlation holds for the change of SZA (Solar Zenith Angle). In different wavelength interval of UVA and UVB, generally, the radiation flux of long wavelength is greater than that of short. Clouds and aerosols in the atmosphere have important influence on ultraviolet irradiance. PMID:17655086

  3. The multi-channel laser focusing transceiver system and analysis of the image quality

    NASA Astrophysics Data System (ADS)

    Sui, Xin; Sun, Hongri; Yang, Kun; Qu, Zhou; Zhang, Bo; Cui, Yihan

    2015-10-01

    This paper has investigated and designed a multi-channel laser focusing transceiver system based on the combination of the laser technology, the space technology and the modern photoelectric detection technology which has the feather of wide wave band, non-chromatic aberration and high quality of image quality etc. The system could be synchronized and can change the distance of detection in a particular direction and obtain the image of atmospheric echo signals at different distances. In this paper we established a multi-channel and variable range laser focusing transceiver system that consists of a single-channel laser focusing transmitter system and a dual-channel receiving telescope system. The three channels of the system depend on the same reference axis. We propose a new method that is capable to improve the laser focusing transceiver system performance. The method is implemented by using parabolic reflector design in the primary and secondary mirror of the variable range laser focusing transmitter system, dual-channel off-axis design in the receiver system and simultaneous imaging design in the different regions of the same CCD target surface of the subsequent imaging system. The detection by two channels using off-axis design would be convenient for computing follow up information. On the base of theoretical basis of the reflective double mirror system and the theory Gaussian beam propagation, this paper calculates the actual converging sot size of the transmitter system and analyzes the wavefront aberration the defocus incidence. The oblique incidence will introduce the certain astigmatism and a small amount of coma and the defocus incidence will produce the certain coma and a small amount of spherical aberration and astigmatism. Finally, an experimental multi-channel laser focusing transceiver system was established and the image quality of the transceiver system on the base of wavefront aberrations, the spot diagram and the MTF curve of some fields is

  4. Estimation of black carbon content for biomass burning aerosols from multi-channel Raman lidar data

    NASA Astrophysics Data System (ADS)

    Talianu, Camelia; Marmureanu, Luminita; Nicolae, Doina

    2015-04-01

    Biomass burning due to natural processes (forest fires) or anthropical activities (agriculture, thermal power stations, domestic heating) is an important source of aerosols with a high content of carbon components (black carbon and organic carbon). Multi-channel Raman lidars provide information on the spectral dependence of the backscatter and extinction coefficients, embedding information on the black carbon content. Aerosols with a high content of black carbon have large extinction coefficients and small backscatter coefficients (strong absorption), while aerosols with high content of organic carbon have large backscatter coefficients (weak absorption). This paper presents a method based on radiative calculations to estimate the black carbon content of biomass burning aerosols from 3b+2a+1d lidar signals. Data is collected at Magurele, Romania, at the cross-road of air masses coming from Ukraine, Russia and Greece, where burning events are frequent during both cold and hot seasons. Aerosols are transported in the free troposphere, generally in the 2-4 km altitude range, and reaches the lidar location after 2-3 days. Optical data are collected between 2011-2012 by a multi-channel Raman lidar and follows the quality assurance program of EARLINET. Radiative calculations are made with libRadTran, an open source radiative model developed by ESA. Validation of the retrievals is made by comparison to a co-located C-ToF Aerosol Mass Spectrometer. Keywords: Lidar, aerosols, biomass burning, radiative model, black carbon Acknowledgment: This work has been supported by grants of the Romanian National Authority for Scientific Research, Programme for Research- Space Technology and Advanced Research - STAR, project no. 39/2012 - SIAFIM, and by Romanian Partnerships in priority areas PNII implemented with MEN-UEFISCDI support, project no. 309/2014 - MOBBE

  5. Multi-channel wireless mapping of gastrointestinal serosal slow wave propagation

    PubMed Central

    Paskaranandavadivel, Niranchan; Wang, Rui; Sathar, Shameer; O’Grady, Gregory; Cheng, Leo K; Farajidavar, Aydin

    2015-01-01

    Background High-resolution (HR) extracellular mapping allows accurate profiling of normal and dysrhythmic slow wave patterns. A current limitation is that cables traverse the abdominal wall or a natural orifice, risking discomfort, dislodgement or infection. Wireless approaches offer advantages, but a multi-channel system is required, capable of recording slow waves and mapping propagation with high fidelity. Methods A novel multi-channel (n=7) wireless mapping system was developed and compared to a wired commercial system. Slow wave signals were recorded from the porcine gastric and intestinal serosa in-vivo. Signals were simultaneously acquired using both systems, and were filtered and processed to map activation wavefronts. For validation, the frequency and amplitude of detected events were compared, together with the speed and direction of mapped wavefronts. Key Results The wireless device achieved comparable signal quality to the reference device, and slow wave frequencies were identical. Amplitudes of the acquired gastric and intestinal slow wave signals were consistent between the devices. During normal propagation, spatiotemporal mapping remained accurate in the wireless system, however, during ectopic dysrhythmic pacemaking, the lower sampling resolution of the wireless device led to reduced accuracy in spatiotemporal mapping. Conclusions and Inferences A novel multichannel wireless device is presented for mapping slow wave activity. The device achieved high quality signals, and has the potential to facilitate chronic monitoring studies and clinical translation of spatiotemporal mapping. The current implementation may be applied to detect normal patterns and dysrhythmia onset, but HR mapping with finely spaced arrays currently remains necessary to accurately define dysrhythmic patterns. PMID:25599978

  6. Self-aligned multi-channel silicon nanowire field-effect transistors

    NASA Astrophysics Data System (ADS)

    Zhu, Hao; Li, Qiliang; Yuan, Hui; Baumgart, Helmut; Ioannou, Dimitris E.; Richter, Curt A.

    2012-12-01

    Si nanowire field effect transistors (SiNW FETs) with multiple nanowire channels and different gate lengths have been fabricated by using a directed assembly approach combined with a standard photolithographic process. The electrical characteristics of SiNW FETs containing different numbers of nanowire channels were measured and compared. The multi-channel SiNW FETs show excellent performance: small subthreshold slope (≈75 mV/dec), large ON/OFF ratio (≈108), good break-down voltage (>30 V) and good carrier mobility (μp ≈ 100 cm2 V-1s-1). These excellent device properties were achieved by using a clean self-alignment process and an improved device structure with Schottky barriers at the source and drain contacts. Such high-performance multi-nanowire FETs are attractive for logic, memory, and sensor applications.

  7. Spectrally resolved multi-channel contributions to the harmonic emission in N2

    NASA Astrophysics Data System (ADS)

    Diveki, Z.; Camper, A.; Haessler, S.; Auguste, T.; Ruchon, T.; Carré, B.; Salières, P.; Guichard, R.; Caillat, J.; Maquet, A.; Taïeb, R.

    2012-02-01

    When generated in molecules, high-order harmonics can be emitted through different ionization channels. The coherent and ultrafast electron dynamics occurring in the ion during the generation process is directly imprinted in the harmonic signal, i.e. in its amplitude and spectral phase. In aligned N2 molecules, we find evidence for a fast variation of this phase as a function of the harmonic order when varying the driving laser intensity. Basing our analysis on a three-step model, we find that this phase variation is a signature of transitions from a single- to a multi-channel regime. In particular, we show that significant nuclear dynamics may occur in the ionization channels on the attosecond timescale, affecting both the amplitude and the phase of the harmonic signal.

  8. Analysis of reconfigurable multi-channel wavelength add drop multiplexer for intelligent optical networks

    NASA Astrophysics Data System (ADS)

    Ponmalar, S.; Sundaravadivelu, S.

    2011-07-01

    This paper presents design of an electro-optically tunable polymer multi-channel wavelength add drop multiplexer (WADM). The proposed WADM with trapezoidal waveguide geometry and poled electro-optical polymer material in the waveguide cores enables the wavelength tuning speed of WADM as 7.5 ps at the resonance wavelength of 1550 nm and coupling length of 1.5 mm. The device can be electro-optically tuned to add/drop multiple channels. Transmission spectra of the device with varying device parameters are simulated. The proposed WADM with high speed, small size and varying tuning capability makes this device, an important element in faster provisioning and routing of light paths in intelligent optical network.

  9. Quick measurement of continuous absorption spectrum in ion beam pulse radiolysis: Application of optical multi-channel detector into transient species observation

    NASA Astrophysics Data System (ADS)

    Iwamatsu, Kazuhiro; Muroya, Yusa; Yamashita, Shinichi; Kimura, Atsushi; Taguchi, Mitsumasa; Katsumura, Yosuke

    2016-02-01

    A quick measurement system of a continuous absorption spectrum covering a wide range from 200 to 950 nm was constructed by employing an optical multi-channel detector. Ion beam pulse radiolysis with 12.5 MeV/u He, 18.3 MeV/u C and 17.5 MeV/u Ne ions were performed with the measurement system. Transient absorption spectrum of (S C N) 2 • - was clearly observed in KSCN aqueous solutions within a few minutes in spite of their very small absorbance, demonstrating high sensitivity of 0.001-0.003 in absorbance in the range from 260 to 660 nm as well as short measurement time of a few minutes. Two different absorption peaks attributed to Br2 • - and Br3 - were observed simultaneously in NaBr aqueous solutions, showing powerfulness of the measurement system in overviewing chemical kinetics under ion beam irradiation especially in not well investigated chemical systems.

  10. Biomimetic Micropatterned Multi-channel Nerve Guides by Templated Electrospinning

    PubMed Central

    Jeffries, Eric; Wang, Yadong

    2012-01-01

    This report describes a new approach for fabricating micro-channels within three-dimensional electrospun constructs. These key features serve to mimic the fascicular architecture and fibrous extracellular matrix found in native nerve. Both electrospun fibers and multi-channeled structure nerve guides have become areas of increasing interest for their beneficial roles in nerve repair. However, to the best of our knowledge, this is the first report of a guide that incorporates both. Multiple parallel channels provide a greater number of defined paths and increased surface area compared to cylindrical guides. Additionally, the fibrous nature of electrospun fibers permits better mass transport than solid-walled constructs. The flexible fabrication scheme allows tailoring of nerve guide parameters such as channel diameters ranging from 33-176μm and various wall thicknesses. Channel and fiber structures were assessed by optical and electron microscope images. Geometric calculations estimated a porosity of over 85% for these guides with 16% or less from the channels. In vitro culture with Schwann cells demonstrated cellular infiltration into channels with restricted migration between fibers. Finally, cell proliferation and survival throughout the guide indicates that this design warrants future in vivo examination. PMID:22179932

  11. A multi-channel fiber optic proximity sensor

    NASA Astrophysics Data System (ADS)

    Kim, Byeong Kwon; Joo, Ki-Nam

    2016-03-01

    In this investigation, we propose an efficient multi-channel optical proximity sensor based on the spectrally-resolved interferometric principle. This sensor consists of a single optical source, a spectrometer and fiber optic components such as an optical circulator, a coarse wavelength division multiplexer (CWDM) and fiber optic probes. A spectrometer is used to detect the spectral interferograms of the measuring probes according to their own spectral bandwidths and the interference signals can be separated by the spectral filtering by a CWDM. The principle of the proposed sensor system was verified with feasibility experiments with the home-built 4 channel sensor system. The measuring range of each channel was 1 mm and the resolution was a few tens of nanometers determined by the deviation of linear motions. The stability of the sensor was less than 30 nm. With the aid of a broadband source and a spectrometer, the measurement channel can be extended further by using a suitable CWDM.

  12. Sequential injection chromatography with a miniaturized multi-channel fiber optic detector for separation and quantification of propranolol and hydrochlorothiazide

    PubMed Central

    2011-01-01

    Background Sequential injection chromatography (SIC) is a new alternative separation technology. It has some advantages over high performance liquid chromatography (HPLC) regarding simplicity, inexpensiveness, portability, ease of use, maintenance requirement and operation time. In contrast, SIC has had suffered from some limitations. Results The current work involves four achievements. (a) One of the limitations of SIC has been overcome. A higher pressure resistant selection valve with additional ports was installed in an SIC system. This development allows propelling solution without showing solution leakage. (b) A new inexpensive rapid and green method for the separation and quantification of propranolol (PRP) and hydrochlorothiazide (HTZ) in their formulations was optimized and validated. (c) A miniaturized multi-channel fiber optic detector was coupled with the newly developed SIC system to detect PRP and HTZ at 270 and 290 nm, respectively. This issue enhanced the sensitivity rather than using a single-channel detector. (d) A comparative study on the efficiency of the SIC method with that of previous HPLC methods was conducted. Conclusions Besides the benefits of the instrumentation of SIC, the proposed method is rapider and more reagent-saving than previous HPLC methods. The total volume of consumed reagents and sample was 4.04 mL. The sample frequency was 22 samples/h. Other such analytical characters of the SIC method as resolution, peak symmetry, numbers of theoretical plates, linearity range, accuracy, precision and limits of detection and quantification recorded comparable results. PMID:21658210

  13. Stacked, filtered multi-channel X-ray diode array

    NASA Astrophysics Data System (ADS)

    MacNeil, L. P.; Dutra, E. C.; Compton, S. M.; Jacoby, B. A.; Raphaelian, M. L.

    2015-08-01

    There are many types of X-ray diodes that are used for X-ray flux or spectroscopic measurements and for estimating the spectral shape of the VUV to soft X-ray spectrum. However, a need arose for a low cost, robust X-ray diode to use for experiments in hostile environments on multiple platforms, and for experiments that utilize forces that may destroy the diode(s). Since the typical proposed use required a small size with a minimal single line-of-sight, a parallel array could not be used. So, a stacked, filtered multi-channel X-ray diode array was developed, called the MiniXRD. To achieve significant cost savings while maintaining robustness and ease of field setup, repair, and replacement, we designed the system to be modular. The filters were manufactured in-house and cover the range from 450 eV to 5000 eV. To achieve the line-of-sight accuracy needed, we developed mounts and laser alignment techniques. We modeled and tested elements of the diode design at NSTec Livermore Operations (NSTec / LO) to determine temporal response and dynamic range, leading to diode shape and circuitry changes to optimize impedance and charge storage. We fielded individual and stacked systems at several national facilities as ancillary `ride-along' diagnostics to test and improve the design usability. We present the MiniXRD system performance which supports consideration as a viable low-cost alternative for multiple-channel low-energy X-ray measurements. This diode array is currently at Technical Readiness Level (TRL) 6.

  14. Demonstration of a multi-channel, low-profile wire gauge for tracing wave development and detonation turning in explosives

    SciTech Connect

    Skidmore, Bradley E; Novak, Alan M; Zucker, Jonathan M; Parker, Jr, Gary R; Dickson, Peter; Foley, Timothy J; Trebs, Adam A

    2010-01-01

    The multi-channel low-profile wire gauge is a device which measures high pressure wave position via the continuous variation in length of a conductor in conjunction with a fiducial, allowing in situ measurement of wave front curvature during wave development. The gauge's low profile ({approx}250 {micro}m) and high resolution measurements (up to 0.5 nanoseconds) make it minimally intrusive and highly responsive, with a typically wave position accuracy of {+-}1 mm. Gauge construction and data analysis methods are described and waveforms are presented for Detasheet and N-9 explosives.

  15. Life-threatening false alarm rejection in ICU: using the rule-based and multi-channel information fusion method.

    PubMed

    Liu, Chengyu; Zhao, Lina; Tang, Hong; Li, Qiao; Wei, Shoushui; Li, Jianqing

    2016-08-01

    False alarm (FA) rates as high as 86% have been reported in intensive care unit monitors. High FA rates decrease quality of care by slowing staff response times while increasing patient burdens and stresses. In this study, we proposed a rule-based and multi-channel information fusion method for accurately classifying the true or false alarms for five life-threatening arrhythmias: asystole (ASY), extreme bradycardia (EBR), extreme tachycardia (ETC), ventricular tachycardia (VTA) and ventricular flutter/fibrillation (VFB). The proposed method consisted of five steps: (1) signal pre-processing, (2) feature detection and validation, (3) true/false alarm determination for each channel, (4) 'real-time' true/false alarm determination and (5) 'retrospective' true/false alarm determination (if needed). Up to four signal channels, that is, two electrocardiogram signals, one arterial blood pressure and/or one photoplethysmogram signal were included in the analysis. Two events were set for the method validation: event 1 for 'real-time' and event 2 for 'retrospective' alarm classification. The results showed that 100% true positive ratio (i.e. sensitivity) on the training set were obtained for ASY, EBR, ETC and VFB types, and 94% for VTA type, accompanied by the corresponding true negative ratio (i.e. specificity) results of 93%, 81%, 78%, 85% and 50% respectively, resulting in the score values of 96.50, 90.70, 88.89, 92.31 and 64.90, as well as with a final score of 80.57 for event 1 and 79.12 for event 2. For the test set, the proposed method obtained the score of 88.73 for ASY, 77.78 for EBR, 89.92 for ETC, 67.74 for VFB and 61.04 for VTA types, with the final score of 71.68 for event 1 and 75.91 for event 2. PMID:27454710

  16. A new multi-channel SAR-GMTI algorithm based on frequency STAP and FrFT

    NASA Astrophysics Data System (ADS)

    Wei, Jun; Yuan, Yunneng; Sun, Jingping; Liu, Shujun; Mao, Shiyi

    2007-11-01

    A SAR-GMTI algorithm based on space-time adaptive processing (STAP) in frequency domain by multi-channel SAR is proposed. The paper deduces the theoretical formula of the clutter suppression in-depth based on frequency STAP and finds that the output is a chirp signal and similar to the input signal of the moving targets before suppressed, so FrFT is chosen to detect them and estimate their moving parameters. The analyses in theory and simulator results show that our new algorithm is effective.

  17. Application of multi-channel photoelastic imaging technology in array type ultrasonic nondestructive testing

    NASA Astrophysics Data System (ADS)

    Fan, Zhen-zhong; Bi, Chao

    2015-08-01

    With the rapid development of modern nondestructive testing technologies, ultrasonic phased array and Ultrasonic array testing technology has been used widely, at the same time the propagation process of ultrasonic in the material becomes more and more complex. In order to make the ultrasonic propagation path become visible and researchers can observe the acoustic field directly, considering the properties of the ultrasonic as a stress wave, according to the theory of polarized light interference, a multi-channel dynamic photoelastic imaging system is developed successfully. The system can generate many kinds of focusing ultrasonic fields in optical specimen by controlling the ultrasonic transmission delay time of each equipment channel, and the system has the ability to simulate the acoustic field's focusing process of the ultrasonic phased array. The image shot by CCD camera reflects the propagation process of the acoustic field in the specimen, and the dynamic video is formed under control of the timing circuit, and the system has the ability to save the captured image in the computer.

  18. Design and implementation of the parallel processing system of multi-channel polarization images

    NASA Astrophysics Data System (ADS)

    Li, Zhi-yong; Huang, Qin-chao

    2013-08-01

    Compared with traditional optical intensity image processing, polarization images processing has two main problems. One is that the amount of data is larger. The other is that processing tasks is more complex. To resolve these problems, the parallel processing system of multi-channel polarization images is designed by the multi-DSP technique. It contains a communication control unit (CCU) and a data processing array (DPA). CCU controls communications inside and outside the system. Its logics are designed by a FPGA chip. DPA is made up of four Digital Signal Processor (DSP) chips, which are interlinked by the loose coupling method. DPA implements processing tasks including images registration and images synthesis by parallel processing methods. The polarization images parallel processing model is designed on multi levels including the system task, the algorithm and the operation. Its program is designed by the assemble language. While the polarization image resolution is 782x582 pixels, the pixel data length is 12 bits in the experiment. After it received 3 channels of polarization image simultaneously, this system implements parallel task to acquire the target polarization characteristics. Experimental results show that this system has good real-time and reliability. The processing time of images registration is 293.343ms while the registration accuracy achieves 0.5 pixel. The processing time of images synthesis is 3.199ms.

  19. A Multi-Channel, Flex-Rigid ECoG Microelectrode Array for Visual Cortical Interfacing

    PubMed Central

    Tolstosheeva, Elena; Gordillo-González, Víctor; Biefeld, Volker; Kempen, Ludger; Mandon, Sunita; Kreiter, Andreas K.; Lang, Walter

    2015-01-01

    High-density electrocortical (ECoG) microelectrode arrays are promising signal-acquisition platforms for brain-computer interfaces envisioned, e.g., as high-performance communication solutions for paralyzed persons. We propose a multi-channel microelectrode array capable of recording ECoG field potentials with high spatial resolution. The proposed array is of a 150 mm2 total recording area; it has 124 circular electrodes (100, 300 and 500 μm in diameter) situated on the edges of concentric hexagons (min. 0.8 mm interdistance) and a skull-facing reference electrode (2.5 mm2 surface area). The array is processed as a free-standing device to enable monolithic integration of a rigid interposer, designed for soldering of fine-pitch SMD-connectors on a minimal assembly area. Electrochemical characterization revealed distinct impedance spectral bands for the 100, 300 and 500 μm-type electrodes, and for the array's own reference. Epidural recordings from the primary visual cortex (V1) of an awake Rhesus macaque showed natural electrophysiological signals and clear responses to standard visual stimulation. The ECoG electrodes of larger surface area recorded signals with greater spectral power in the gamma band, while the skull-facing reference electrode provided higher average gamma power spectral density (γPSD) than the common average referencing technique. PMID:25569757

  20. Automated Interval velocity picking for Atlantic Multi-Channel Seismic Data

    NASA Astrophysics Data System (ADS)

    Singh, Vishwajit

    2016-04-01

    This paper described the challenge in developing and testing a fully automated routine for measuring interval velocities from multi-channel seismic data. Various approaches are employed for generating an interactive algorithm picking interval velocity for continuous 1000-5000 normal moveout (NMO) corrected gather and replacing the interpreter's effort for manual picking the coherent reflections. The detailed steps and pitfalls for picking the interval velocities from seismic reflection time measurements are describe in these approaches. Key ingredients these approaches utilized for velocity analysis stage are semblance grid and starting model of interval velocity. Basin-Hopping optimization is employed for convergence of the misfit function toward local minima. SLiding-Overlapping Window (SLOW) algorithm are designed to mitigate the non-linearity and ill- possessedness of root-mean-square velocity. Synthetic data case studies addresses the performance of the velocity picker generating models perfectly fitting the semblance peaks. A similar linear relationship between average depth and reflection time for synthetic model and estimated models proposed picked interval velocities as the starting model for the full waveform inversion to project more accurate velocity structure of the subsurface. The challenges can be categorized as (1) building accurate starting model for projecting more accurate velocity structure of the subsurface, (2) improving the computational cost of algorithm by pre-calculating semblance grid to make auto picking more feasible.

  1. Objective research and application of multi-channel human meridian impedance dynamic testing system

    NASA Astrophysics Data System (ADS)

    Li, Bo; Zhang, Jun; Jiao, Jianling

    2008-10-01

    This paper is an in-depth study on the basis of the passed summary of relevant technologies. Multi-channel ring electrode has been developed to point impedance testing of the human body for the first time. Here, we build such a system, which bases on the hardware platform of AT89C52 combined with M82C54-2, besides, the integrated software development tools micro-soft visual c++ and the technical advantages such as multi-threading, databases, serial communication and the characteristics of real-time supported by Windows XP are used in here too. Except for the point impedance testing of the human body, the conductive volume of the human meridian and infrared-photoelectric absorption properties of physical quantities can also be detected by such an on-site data acquisition, analysis, display, record and communicate with the PC portable System. Currently, the system was being in the testing phase, we have collected some real data of human body with this vehicle, whose results are expected to be more satisfactory in the near future.

  2. Design Study of a Multi-channel Array Particle Spectrometer for Space Missions

    NASA Astrophysics Data System (ADS)

    Trindade, Andreia; Assis, P.; Brogueira, P.; Gonçalves, P.; Keating, A.; Pimenta, M.; Rodrigues, P.; Trindade, A.

    In this work, a novel particle spectrometer is proposed to fulfil the need to map the space radiation environment for future space missions and to provide more accurate scientific data. The concept of the instrument brings together new radiation-hard technologies, for the photo-sensors and scintillating materials that will improve the quality of the data, while taking into account the limited resources such as mass, power and accommodation, allocated for space radiation monitors. The Multi-channel Array Particle Spectrometer (MAPS), can measure fluxes and energy dis-tributions of protons, ions, electrons and gammas in a wide energy range based on the 3D reconstruction of the particle track through the detector and its deposited energy in the active volume. It consists on a 8 x 8 segmented scintillator block built from 3.2 x 3.2 x 20 mm3 indi-vidual LYSO:Ce rods that are readout at both ends by two 64 pixel Silicon Photo-Multipliers (SiPMs) matrices, a new generation of high gain (105-106) avalanche photodiodes working in controlled Geiger mode, that collect the scintillating light produced by the interactions of the charged particles in the crystals. Each SiPM matrix is readout by a 64 channel mixed sig-nal analog-digital ASIC, offering both particle identification and particle counting capabilities. Power cycling design of the ASIC allows to activate the particle identification block only during a pre-determined time slice, keeping the total power budget of less than 1 mW/channel. An on-board FPGA sorts the serialized data from the two ASICs and computes the trigger primitives in real-time and in an event-by-event basis. Whenever a charged particle crosses the segmented volume of the detector, the XY coordinates, given by the pixelized crystal positions, and the deposited energy in each crystal is recorded. The double readout scheme allows to compute the light collection asymmetry between both ends of the crystal and to use that information to record the

  3. Multi-channel purge and trap system coupled with ion chromatography for the determination of alkylamines in cosmetics.

    PubMed

    Zhong, Zhixiong; Li, Gongke; Luo, Zhibin; Zhu, Binghui

    2012-02-17

    A new multi-channel purge and trap system coupled with ion chromatography for the determination of six alkylamines in cosmetics was developed. The proposed method, based on purge and trap of the volatile alkylamines, involved in a miniaturization and multi-channel integration of classical steam distillation and a simple approach for routine labs. The procedure was rapidly achieved within 10 min and the matrix interferences could be effectively eliminated. Sample pretreatment frequency was higher than 40 h(-1). The linear ranges were 0.1-15 mg L(-1) and the detection limits varied from 0.023 to 0.038 mg L(-1). This method was successfully utilized to determine the amounts of alkylamines in cosmetics with recoveries ranging from 80.3 to 105.5% and the relative standard deviations (RSDs) ranging from 0.78 to 7.5%. It was proved to be accurate, time-saving, and suitable for the determination of large numbers of cosmetics in a short time. PMID:22244166

  4. A low-offset analogue front-end IC for multi-channel physiological signal acquisition.

    PubMed

    Zhang, Jinyong; Wang, Lei; Yu, Li; Yang, Yabei; Zhang, Yuanting; Li, Bin

    2009-01-01

    This paper describes a low-offset analogue front-end (AFE) integrated circuit (IC) for multi-channel physiological signal acquisitions. The mixed signal IC consists of low-offset gain programmable instrumentation amplifiers (GPIAs), high sensitive current-to-voltage converters (I-V converters), reference and an 8-bit analogue-to-digital converter (ADC). The IC offered adjustable gains that were elaborated for various physiological signal acquisitions. The conditional signals were quantized by ADC that offered an optimal solution for portable applications. The circuit was fabricated in SMIC 0.18-mum mixed-signal CMOS technology, and core area of the whole IC measured 1.36 mm(2). The post-annotated simulations suggested that the system achieved a common-mode-rejection-ration (CMRR) of 142 dB, the adjustable gain from 31.6 dB to 76.5 dB, and the offset voltage less than 80 microV. The 8-bit ADC exhibited less than 0.8 LSB DNL and 1.1 LSB INL. Power dissipation of each channel and the ADC were approximately 348 microW and 1.65 mW under a 1.8 V single supply voltage, respectively. It is suitable for a wide range of high precision biomedical applications. PMID:19964636

  5. Non-local Atlas-guided Multi-channel Forest Learning for Human Brain Labeling

    PubMed Central

    Ma, Guangkai; Gao, Yaozong; Wu, Guorong; Wu, Ligang; Shen, Dinggang

    2015-01-01

    Labeling MR brain images into anatomically meaningful regions is important in many quantitative brain researches. In many existing label fusion methods, appearance information is widely used. Meanwhile, recent progress in computer vision suggests that the context feature is very useful in identifying an object from a complex scene. In light of this, we propose a novel learning-based label fusion method by using both low-level appearance features (computed from the target image) and high-level context features (computed from warped atlases or tentative labeling maps of the target image). In particular, we employ a multi-channel random forest to learn the nonlinear relationship between these hybrid features and the target labels (i.e., corresponding to certain anatomical structures). Moreover, to accommodate the high inter-subject variations, we further extend our learning-based label fusion to a multi-atlas scenario, i.e., we train a random forest for each atlas and then obtain the final labeling result according to the consensus of all atlases. We have comprehensively evaluated our method on both LONI-LBPA40 and IXI datasets, and achieved the highest labeling accuracy, compared to the state-of-the-art methods in the literature. PMID:26942235

  6. Scalable Geiger/APD/PIN multi-channel sensing platform

    NASA Astrophysics Data System (ADS)

    Buckley, Steve; Bellis, Stephen; Wilcock, Reuben; Mathewson, Alan; Jackson, J. Carlton

    2006-02-01

    Previous generation low light detection platforms have been based on the photomultiplier tube (PMT) or the silicon single photon counting module (SPCM) from Perkin Elmer1. A new generation of silicon CMOS compatible photon counting sensors are being developed offering high quantum efficiency, low operating voltage, high levels of robustness and compatibility with CMOS processing for integration into large format imaging arrays. This latest generation yields a new detector for emerging applications which demand photon counting performance providing high performance and flexibility not possible to date. We describe a 4-channel photon detection platform, which allows the use of 4 separate photon counting detectors in either free space or fibre-coupled mode. The platform is scalable up to 16 channels with plug in modules allowing active quenching or Peltier cooling as required. A graphical user interface allows feedback and control of all device parameters. We show a novel ability to integrate separate detection modules to extend the dynamic range of the system. This allows a PIN or APD mode detector to be used alongside sensitive photon counting detectors. An advanced FPGA and microcontroller interface has been designed which allows simultaneous time binning of counting rates and readout of the analog signals when used with linear detectors. This new architecture will be discussed, presenting a full characterization of count rate, quantum efficiency, time binning and sensitivity across the broad spectrum of light flux applicable to PIN diodes, APDs and Geiger-mode photon counting sensors.

  7. A Radiation Hard Multi-Channel Digitizer ASIC for Operation in the Harsh Jovian Environment

    NASA Technical Reports Server (NTRS)

    Aslam, Shahid; Aslam, S.; Akturk, A.; Quilligan, G.

    2011-01-01

    ultimately impact the surface of Europa after the mission is completed. The current JEO mission concept includes a range of instruments on the payload, to monitor dynamic phenomena (such as Io's volcanoes and Jupiters atmosphere), map the Jovian magnetosphere and its interactions with the Galilean satellites, and characterize water oceans beneath the ice shells of Europa and Ganymede. The payload includes a low mass (3.7 Kg) and low power (< 5 W) Thermal Instrument (TI) concept for measuring possible warm thermal anomalies on Europa s cold surface caused by recent (< 10,000 years) eruptive activity. Regions of anomalously high heat flow will be identified by thermal mapping using a nadir pointing, push-broom filter radiometer that provides far-IR imagery in two broad band spectral wavelength regions, 8-20 m and 20-100 m, for surface temperature measurements with better than a 2 K accuracy and a spatial resolution of 250 m/pixel obtained from a 100 Km orbit. The temperature accuracy permits a search for elevated temperatures when combined with albedo information. The spatial resolution is sufficient to resolve Europa's larger cracks and ridge axial valleys. In order to accomplish the thermal mapping, the TI uses sensitive thermopile arrays that are readout by a custom designed low-noise Multi-Channel Digitizer (MCD) ASIC that resides very close to the thermopile linear array outputs. Both the thermopile array and the MCD ASIC will need to show full functionality within the harsh Jovian radiation environment, operating at cryogenic temperatures, typically 150 K to 170 K. In the following, a radiation mitigation strategy together with a low risk Radiation-Hardened-By-Design (RHBD) methodology using commercial foundry processes is given for the design and manufacture of a MCD ASIC that will meet this challenge.

  8. A multi-channel biomimetic neuroprosthesis to support treadmill gait training in stroke patients.

    PubMed

    Chia, Noelia; Ambrosini, Emilia; Baccinelli, Walter; Nardone, Antonio; Monticone, Marco; Ferrigno, Giancarlo; Pedrocchi, Alessandra; Ferrante, Simona

    2015-08-01

    This study presents an innovative multi-channel neuroprosthesis that induces a biomimetic activation of the main lower-limb muscles during treadmill gait training to be used in the rehabilitation of stroke patients. The electrostimulation strategy replicates the physiological muscle synergies used by healthy subjects to walk on a treadmill at their self-selected speed. This strategy is mapped to the current gait sub-phases, which are identified in real time by a custom algorithm. This algorithm divides the gait cycle into six sub-phases, based on two inertial sensors placed laterally on the shanks. Therefore, the pre-defined stimulation profiles are expanded or stretched based on the actual gait pattern of each single subject. A preliminary experimental protocol, involving 10 healthy volunteers, was carried out to extract the muscle synergies and validate the gait-detection algorithm, which were afterwards used in the development of the neuroprosthesis. The feasibility of the neuroprosthesis was tested on one healthy subject who simulated different gait patterns, and a chronic stroke patient. The results showed the correct functioning of the system. A pilot study of the neurorehabilitation treatment for stroke patients is currently being carried out. PMID:26737943

  9. Audio representations of multi-channel EEG: a new tool for diagnosis of brain disorders

    PubMed Central

    Vialatte, François B; Dauwels, Justin; Musha, Toshimitsu; Cichocki, Andrzej

    2012-01-01

    Objective: The objective of this paper is to develop audio representations of electroencephalographic (EEG) multichannel signals, useful for medical practitioners and neuroscientists. The fundamental question explored in this paper is whether clinically valuable information contained in the EEG, not available from the conventional graphical EEG representation, might become apparent through audio representations. Methods and Materials: Music scores are generated from sparse time-frequency maps of EEG signals. Specifically, EEG signals of patients with mild cognitive impairment (MCI) and (healthy) control subjects are considered. Statistical differences in the audio representations of MCI patients and control subjects are assessed through mathematical complexity indexes as well as a perception test; in the latter, participants try to distinguish between audio sequences from MCI patients and control subjects. Results: Several characteristics of the audio sequences, including sample entropy, number of notes, and synchrony, are significantly different in MCI patients and control subjects (Mann-Whitney p < 0.01). Moreover, the participants of the perception test were able to accurately classify the audio sequences (89% correctly classified). Conclusions: The proposed audio representation of multi-channel EEG signals helps to understand the complex structure of EEG. Promising results were obtained on a clinical EEG data set. PMID:23383399

  10. Centralized Routing and Scheduling Using Multi-Channel System Single Transceiver in 802.16d

    NASA Astrophysics Data System (ADS)

    Al-Hemyari, A.; Noordin, N. K.; Ng, Chee Kyun; Ismail, A.; Khatun, S.

    This paper proposes a cross-layer optimized strategy that reduces the effect of interferences from neighboring nodes within a mesh networks. This cross-layer design relies on the routing information in network layer and the scheduling table in medium access control (MAC) layer. A proposed routing algorithm in network layer is exploited to find the best route for all subscriber stations (SS). Also, a proposed centralized scheduling algorithm in MAC layer is exploited to assign a time slot for each possible node transmission. The cross-layer optimized strategy is using multi-channel single transceiver and single channel single transceiver systems for WiMAX mesh networks (WMNs). Each node in WMN has a transceiver that can be tuned to any available channel for eliminating the secondary interference. Among the considered parameters in the performance analysis are interference from the neighboring nodes, hop count to the base station (BS), number of children per node, slot reuse, load balancing, quality of services (QoS), and node identifier (ID). Results show that the proposed algorithms significantly improve the system performance in terms of length of scheduling, channel utilization ratio (CUR), system throughput, and average end to end transmission delay.

  11. Implementation of a miniature sized, battery powered electrophysiological signal-generator for testing multi-channel recording equipments.

    PubMed

    Máthé, Kálmán; Tóth, Attila; Petykó, Zoltán; Szabó, Imre; Czurkó, András

    2007-09-15

    Testing electrophysiological recording equipments is an important task in multi-channel extracellular in vivo electrophysiology. In this paper, a miniature, battery powered multi-channel electrophysiological signal-generator (ESG) is described that was designed for this purpose. The device is based on a Xilinx CPLD (Complex Programmable Logic Device) and it is powered by a 3V lithium coin battery. It is a useful tool for calibration and testing the performance, quality and parameters of the recording equipments used for acquiring EEG, field potentials, ECG, EMG, and multiple unit activity. The device is ideally suited to identify instances when errors interfere with the proper recording, and repair of wiring or service of the equipment is needed. Two versions of the device are described; one is for 16 (ESG16), and another is for 32 channels (ESG32). Both versions provide amplitude and time calibration, as well as cross-talk and CMRR (common mode rejection ratio) testing for the recording equipment. PMID:17624440

  12. Multi-channel pulser for the SLC thermionic electron source

    SciTech Connect

    Browne, M.J.; Clendenin, J.E.; Corredoura, P.L.; Jobe, R.K.; Koontz, R.F.; Sodja, J.

    1985-01-01

    A new pulser developed for the SLC thermionic gun has been operational since September 1984. It consists of two planar triode amplifiers with a common output triode driving the gun cathode to produce two independent pulses of up to 9A with a 3 nsec FWHM pulse width. Three long-pulse amplifiers are also connected to the cathode to produce pulses with widths controllable between 100 nsec and 1.6 ..mu..sec. Each amplifier has independent timing and amplitude control through a fiber optic link to the high voltage plane of the gun cathode-grid structure. The pulser and its operating characteristics are described. 15 refs., 3 figs.

  13. The application of elastomeric connector for multi-channel electrophysiological recordings.

    PubMed

    Szabó, Imre; Máthé, Kálmán; Tóth, Attila; Hernádi, István; Czurkó, András

    2002-02-15

    Interest in recording multi-channel electrophysiological data from behaving animals is rapidly growing, and many laboratories tend to record a large number of EEG and/or multi-unit channels, despite the limitation of the size of the headpiece that a small behaving animal can carry. A common drawback of these experiments, therefore, is the relatively large size of even the smallest, commercially available, high-density micro-connectors for the headset. To overcome this problem, we suggest the application of elastomeric or silicone inter-rubber connectors, that are widely used in electronics. The elastomeric or "zebra" connector consists of alternating thin strips of layered electrically conductive and non-conductive materials. The conductive strips provide electrical connections between uninsulated contact surfaces of printed circuit boards such as the connector plate of the micro-drive, that holds the brain electrode wires, and the preamplifier board of the recording system. In the present paper, we provide technical details of the design of this type of connector-sets and discuss common issues arising from their use. By comparing the applicability of two designs, we aim to demonstrate the simplicity, reliability and durability of the elastomeric inter-rubber connectors in electrophysiological experiments on freely moving laboratory animals. PMID:11850041

  14. A multi-channel telemetry system for brain microstimulation in freely roaming animals.

    PubMed

    Xu, Shaohua; Talwar, Sanjiv K; Hawley, Emerson S; Li, Lei; Chapin, John K

    2004-02-15

    A system is described that enables an experimenter to remotely deliver electrical pulse train stimuli to multiple different locations in the brains of freely moving rats. The system consists of two separate components: a transmitter base station that is controlled by a PC operator, and a receiver-microprocessor integrated pack worn on the back of the animals and which connects to suitably implanted brain locations. The backpack is small and light so that small animal subjects can easily carry it. Under remote command from the PC the backpack can be configured to provide biphasic pulse trains of arbitrarily specified parameters. A feature of the system is that it generates precise brain-stimulation behavioral effects using the direct constant-voltage TTL output of the backpack microprocessor. The system performs with high fidelity even in complex environments over a distance of about 300 m. Rat self-stimulation tests showed that this system produced the same behavioral responses as a conventional constant-current stimulator. This system enables a variety of multi-channel brain stimulation experiments in freely moving animals. We have employed it to develop a new animal behavior model ("virtual" conditioning) for the neurophysiological study of spatial learning, in which a rat can be accurately guided to navigate various terrains. PMID:14757345

  15. Monitoring of ion implantation in microelectronics production environment using multi-channel reflectometry

    NASA Astrophysics Data System (ADS)

    Ebersbach, Peter; Urbanowicz, Adam M.; Likhachev, Dmitry; Hartig, Carsten

    2016-03-01

    Optical metrology techniques such as ellipsometry and reflectometry are very powerful for routine process monitoring and control in the modern semiconductor manufacturing industry. However, both methods rely on optical modeling therefore, the optical properties of all materials in the stack need to be characterized a priori or determined during characterization. Some processes such as ion implantation and subsequent annealing produce slight variations in material properties within wafer, wafer-to-wafer, and lot-to-lot; such variation can degrade the dimensional measurement accuracy for both unpatterned optical measurements as well as patterned (2D and 3D) scatterometry measurements. These variations can be accounted for if the optical model of the structure under investigation allows one to extract not just dimensional but also material information already residing within the optical spectra. This paper focuses on modeling of ion implanted and annealed poly Si stacks typically used in high-k technology. Monitoring of ion implantation is often a blind spot in mass production due to capability issues and other limitations of common methods. Typically, the ion implantation dose can be controlled by research-grade ellipsometers with extended infrared range. We demonstrate that multi-channel spectroscopic reflectometry can also be used for ion implant monitoring in the mass-production environment. Our findings are applicable across all technology nodes.

  16. Automated Filtering of Common Mode Artifacts in Multi-Channel Physiological Recordings

    PubMed Central

    Kelly, John W.; Siewiorek, Daniel P.; Smailagic, Asim; Wang, Wei

    2014-01-01

    The removal of spatially correlated noise is an important step in processing multi-channel recordings. Here, a technique termed the adaptive common average reference (ACAR) is presented as an effective and simple method for removing this noise. The ACAR is based on a combination of the well-known common average reference (CAR) and an adaptive noise canceling (ANC) filter. In a convergent process, the CAR provides a reference to an ANC filter, which in turn provides feedback to enhance the CAR. This method was effective on both simulated and real data, outperforming the standard CAR when the amplitude or polarity of the noise changes across channels. In many cases the ACAR even outperformed independent component analysis (ICA). On 16 channels of simulated data the ACAR was able to attenuate up to approximately 290 dB of noise and could improve signal quality if the original SNR was as high as 5 dB. With an original SNR of 0 dB, the ACAR improved signal quality with only two data channels and performance improved as the number of channels increased. It also performed well under many different conditions for the structure of the noise and signals. Analysis of contaminated electrocorticographic (ECoG) recordings further showed the effectiveness of the ACAR. PMID:23708770

  17. Salt Plug Formation Caused by Decreased River Discharge in a Multi-channel Estuary.

    PubMed

    Shaha, Dinesh Chandra; Cho, Yang-Ki

    2016-01-01

    Freshwater input to estuaries may be greatly altered by the river barrages required to meet human needs for drinking water and irrigation and prevent salt water intrusion. Prior studies have examined the salt plugs associated with evaporation and salt outwelling from tidal salt flats in single-channel estuaries. In this work, we discovered a new type of salt plug formation in the multi-channel Pasur River Estuary (PRE) caused by decreasing river discharges resulting from an upstream barrage. The formation of a salt plug in response to changes in river discharge was investigated using a conductivity-temperature-depth (CTD) recorder during spring and neap tides in the dry and wet seasons in 2014. An exportation of saline water from the Shibsa River Estuary (SRE) to the PRE through the Chunkhuri Channel occurred during the dry season, and a salt plug was created and persisted from December to June near Chalna in the PRE. A discharge-induced, relatively high water level in the PRE during the wet season exerted hydrostatic pressure towards the SRE from the PRE and thereby prevented the intrusion of salt water from the SRE to the PRE. PMID:27255892

  18. Salt Plug Formation Caused by Decreased River Discharge in a Multi-channel Estuary

    NASA Astrophysics Data System (ADS)

    Shaha, Dinesh Chandra; Cho, Yang-Ki

    2016-06-01

    Freshwater input to estuaries may be greatly altered by the river barrages required to meet human needs for drinking water and irrigation and prevent salt water intrusion. Prior studies have examined the salt plugs associated with evaporation and salt outwelling from tidal salt flats in single-channel estuaries. In this work, we discovered a new type of salt plug formation in the multi-channel Pasur River Estuary (PRE) caused by decreasing river discharges resulting from an upstream barrage. The formation of a salt plug in response to changes in river discharge was investigated using a conductivity-temperature-depth (CTD) recorder during spring and neap tides in the dry and wet seasons in 2014. An exportation of saline water from the Shibsa River Estuary (SRE) to the PRE through the Chunkhuri Channel occurred during the dry season, and a salt plug was created and persisted from December to June near Chalna in the PRE. A discharge-induced, relatively high water level in the PRE during the wet season exerted hydrostatic pressure towards the SRE from the PRE and thereby prevented the intrusion of salt water from the SRE to the PRE.

  19. Subjective evaluation of auralizations created from multi-channel anechoic recordings of a talker in motion

    NASA Astrophysics Data System (ADS)

    Vigeant, Michelle C.; Wang, Lily M.

    2005-04-01

    A high degree of speech intelligibility is very important in educational environments. When designing such spaces, like classrooms, auralizations can be used to subjectively assess the degree of speech intelligibility and clarity. Auralizations are most commonly made by convolving the impulse response (IR) of an omni-directional source with a single channel anechoic speech recording. This paper explores the idea of using multi-channel recordings to create the auralizations, using a female talker in motion. An omni-directional source is split into quadrants and the IR is calculated for each section. These IR's are convolved with the appropriate channel of the anechoic recording and then the four auralizations are mixed to create one final auralization. The auralizations were made using four-channel anechoic recordings of a person walking on a platform while talking. Subjective tests were conducted to determine the ease with which subjects could identify the direction of the movement of the source in rooms with varying amounts of absorption. This method can be used to create more realistic classroom auralizations, as teachers typically move around the room as they teach. [Work supported by the National Science Foundation.

  20. Salt Plug Formation Caused by Decreased River Discharge in a Multi-channel Estuary

    PubMed Central

    Shaha, Dinesh Chandra; Cho, Yang-Ki

    2016-01-01

    Freshwater input to estuaries may be greatly altered by the river barrages required to meet human needs for drinking water and irrigation and prevent salt water intrusion. Prior studies have examined the salt plugs associated with evaporation and salt outwelling from tidal salt flats in single-channel estuaries. In this work, we discovered a new type of salt plug formation in the multi-channel Pasur River Estuary (PRE) caused by decreasing river discharges resulting from an upstream barrage. The formation of a salt plug in response to changes in river discharge was investigated using a conductivity-temperature-depth (CTD) recorder during spring and neap tides in the dry and wet seasons in 2014. An exportation of saline water from the Shibsa River Estuary (SRE) to the PRE through the Chunkhuri Channel occurred during the dry season, and a salt plug was created and persisted from December to June near Chalna in the PRE. A discharge-induced, relatively high water level in the PRE during the wet season exerted hydrostatic pressure towards the SRE from the PRE and thereby prevented the intrusion of salt water from the SRE to the PRE. PMID:27255892

  1. 802.11s based multi-radio multi-channel mesh networking for fractionated spacecraft

    NASA Astrophysics Data System (ADS)

    Michel, Tony; Thapa, Bishal; Taylor, Steve

    802.11s is a new IEEE standard for mesh networking. It defines the protocols needed to build mobile ad hoc networks that operate over 802.11a, b, g and n waveforms running on inexpensive, and high performance commercial WiFi stations. We have developed a new capability to add to the 802.11s that uses multiple directional radio links that can operate simultaneously within a single mesh node. This is the basis of our multi-channel multi-radio mesh network used in the DARPA F6 program called F6Net. We have developed an analysis and emulation facility that lets us model the F6Net and evaluate the performance in a real world experimentation setup. This paper presents an “ Over-the-Air” experimentation testbed that uses standard Commercial Off-The-Shelf (COTS) 2.4GHz WiFi dongles in an indoor environment, and a shared-code simulation testbed that uses hardware simulated drivers within NS3's channel simulation facility to test 80211s network. To the best of our knowledge, this is the first work that provides a comprehensive evaluation platform with a full-fledged COTS hardware/software prototype to evaluate 802.11s network. Furthermore, we explain the design and development of multi-radio mesh extension for 802.11s that yields a robust and scalable mesh network suitable for clusters of LEO satellites.

  2. Electrical properties of flexible multi-channel Si nanowire field-effect transistors depending on the number of Si nanowires.

    PubMed

    Kim, Do Hoon; Lee, Su Jeong; Lee, Sang Hoon; Myoung, Jae-Min

    2016-05-25

    Flexible multi-channel Si nanowire (NW) field-effect transistors (FETs) were investigated to determine the effect of the number of Si NWs. The Langmuir-Blodgett method was applied for the formation of well-aligned Si NW monolayers, and an ion-gel with a high dielectric constant was used as a gate insulator in a top-gate TFT structure to secure flexibility. Like typical nanoelectronic devices, the drain current changed with the number of Si NWs. However, unlike previous reports, the mobility of the multi-channel Si NW FETs increased from 42.8 to 124.6 cm(2) V(-1) s(-1) as the number of Si NWs was increased from 1 to 58. To verify the feasibility of our approach, the electrical performance of the TFTs fabricated on a flexible polyimide (PI) substrate was analyzed in respect of the bending strain (0.08-1.51%) and bending cycle (up to 12 000 cycles). As the number of Si NWs was increased, the trade-off between electrical and mechanical properties during bending tests was confirmed, and the appropriate number of Si NWs was optimized for a flexible FET with excellent performance. PMID:27149060

  3. Development of a multi-channel readout ASIC for a fast neutron spectrometer based on GEM-TPC

    NASA Astrophysics Data System (ADS)

    He, Li; Deng, Zhi; Liu, Yi-Nong; Li, Yu-Lan

    2014-10-01

    A multi-channel front-end ASIC has been developed for a fast neutron spectrometer based on Gas Electron Multiplier (GEM)-Time Projection Chamber (TPC). Charge Amplifier and Shaping Amplifier for GEM (CASAGEM) integrates 16+1 channels: 16 channels for anodes and 1 channel for cathode. The gain and the shaping time are adjustable from 2 to 40 mV/fC and from 20 to 80 ns, respectively. The prototype ASIC is fabricated in 0.35 μm CMOS process. An evaluation Print Circuit Board (PCB) was also developed for chip tests. In total 20 chips have been tested. The integrated nonlinearity is less than 1%. The equivalent noise electrons is less than 2000e when the input capacitor is 50 pF. The time jitter is less than 1 ns. The design and the test results are presented in the paper.

  4. An Adaptive Multi-Channel Spectroellipsometer for Ecological Monitoring

    NASA Astrophysics Data System (ADS)

    Mkrtchyan, F. A.; Kovalev, V. I.; Klimov, V. V.

    2011-09-01

    The creation of multichannel polarization optical instrumentation and use of spectroellipsometric technology are very important for the real-time ecological control of aquatic environment. Spectroellipsometric devices give us high precision of measurements. This report is aimed to describe: •A technology of combined use of spectroellipsometry and algorithms of identification and recognition that allowed the creation of a standard integral complex of instrumental, algorithmic, modular and software tools for the collection and processing of data on the aquatic environment quality with forecasting and decision - making functions. •A compact measuring - information multichannel spectroellipsometric system (device) for monitoring the quality of aquatic environment, that is based on the combined use of spectroellipsometry and training, classification, and identification algorithms. This spectroellipsometric system will differ from modern foreign analogues by the use of a new and very promising method of ellipsometric measurements, an original element base of polarization optics and a complex mathematical approach to estimating the quality of a water object subjected to anthropogenic influence.Unlike foreign analogues, the system has no rotating polarization elements. This allows one to increase the signal-to-noise ratio and the long-term stability of measurements, to simplify and reduce the price of multichannel spectroellipsometers. The system will be trainable to the recognition of the pollutants of aquatic environment. A spectroellipsometer in laboratories of V.A. Kotelnikov's Institute of Radioengineering and Electronics, Russian Academy of Sciences is designed for in-situ real time measurements of spectra of ellipsometric parameters Psi and Delta with consequent changeover to spectra of transmitted and reflected signal from water media in frames of used physical model of water environment.

  5. A Multi-Channel Approach for Collaborative Web-Based Learning

    ERIC Educational Resources Information Center

    Azeta, A. A.

    2008-01-01

    This paper describes an architectural framework and a prototype implementation of a web-based multi-channel e-Learning application that allows students, lecturers and the research communities to collaborate irrespective of the communication device a user is carrying. The application was developed based on the concept of "right once run on any…

  6. Retrievals on Tropical small scale humidity variability from multi-channel microwave radiometer

    NASA Astrophysics Data System (ADS)

    Zhang, Jianhao; Zuidema, Paquita; Turner, David

    2016-04-01

    Small-scale atmospheric humidity structure is important to many atmospheric process studies. In the Tropics especially, convection is sensitive to small variations in humidity. High temporal-resolution humidity profiles and spatially-resolved humidity fields are valuable for understanding the relationship of convection to tropical humidity, such as at convectively-induced cold pools and as part of the shallow-to-deep cloud transition. Radiosondes can provide high resolution vertical profiles of temperature and humidity, but are relatively infrequent. Microwave radiometers (MWR) are able to profile and scan autonomously and output measurements frequently (~1 Hz). To date, few assessments of microwave humidity profiling in the Tropics have been undertaken. Löhnert et al. (2009) provide one evaluation for Darwin, Australia. We build on this using four months of data from the equatorial Indian Ocean, at Gan Island, collected from University of Miami's (UM) multi-channel radiometer during the Dynamics of Madden-Julian Oscillation (DYNAMO) field campaign. Liquid Water Path (LWP) and Water Vapor Path (WVP) are physically retrieved using the MWR RETrieval (MWRRET) algorithm (Turner et al., 2007b), and humidity profiles in the tropics are retrieved using the Integrated Profiling Technique (Löhnert et al., 2004). Tropical temperature variability is weak and a climatological temperature profile is assumed, with humidity information drawn from five channels between 22 to 30 GHz. Scanning measurements were coordinated with the scanning pattern of NCAR's S-Pol-Ka radar. An analysis of the humidity information content gathered from both the profiling and scanning measurements will be presented.

  7. Simple charge division readouts for imaging scintillator arrays using a multi-channel PMT

    SciTech Connect

    Siegel, S.; Silverman, R.W.; Shao, Y.; Cherry, S.R.

    1996-06-01

    Three simple charge division circuits were assembled and tested as 2-D position encoding readouts for multi-channel photomultiplier tubes (MC-PMT). They were evaluated with an 8 x 8 array of individual scintillators (2 x 2 x 10 mm BGO) coupled to a 64 channel MC-PMT (Philips XP1722) via 25 cm long, 2 mm diameter, double clad, optical fibers (Kuraray). This type of gamma-ray imaging detector has many potential applications in medical and industrial imaging. Though independent channel readout would allow for the discrimination of scatter within the array, and higher count rates, it would also require an excessive amount of supporting electronics. This is especially true for systems comprised of many MC-PMTs. In this study, the number of channels being read out was reduced from 64 to 4 using three different simple resistor networks. These circuits take advantage of the discretized nature of the scintillator array, the low interchannel crosstalk of the MC-PMT and low input impedance current-sensitive preamplifiers. For each circuit, the scintillator identification accuracy was compared. The identification accuracy as a function of deposited energy was also determined by exposure to various gamma-ray emitters. It was found that the preamplifier circuit noise contributed the most to the degradation of the detector`s spatial response so several low noise op amps were evaluated. It was also determined that keeping the preamplifier input impedance small was necessary for accurate positioning. The coincidence timing resolution of the detector (15 ns) is only slightly degraded by the readout circuit.

  8. Measurement of mode coupling distribution along a few-mode fiber using a synchronous multi-channel OTDR.

    PubMed

    Nakazawa, Masataka; Yoshida, Masato; Hirooka, Toshihiko

    2014-12-15

    We describe the nondestructive measurement of mode coupling along a few-mode fiber using a synchronous multi-channel optical time-domain reflectometer (OTDR). By installing a few-mode fiber (FMF) coupler made with a phase mask method, we excite the LP01 mode in an FMF under the test as an input mode, and then we detect backward Rayleigh scattered LP11a or LP11b modes, which were generated as a result of the mode coupling through the coupler. The mode coupling distribution between the LP01 and LP11a,b modes along the test FMF was successfully measured with a 10-m spatial resolution by obtaining the ratio between the backscattered LP01 mode and LP11a or LP11b. The value of the mode coupling obtained with the present method agreed well with that obtained with the conventional transmission method. PMID:25607078

  9. The SRI24 Multi-Channel Atlas of Normal Adult Human Brain Structure

    PubMed Central

    Rohlfing, Torsten; Zahr, Natalie M.; Sullivan, Edith V.; Pfefferbaum, Adolf

    2010-01-01

    This paper describes the SRI24 atlas, a new standard reference system of normal human brain anatomy, that was created using template-free population registration of high-resolution magnetic resonance images acquired at 3T in a group of 24 normal control subjects. The atlas comprises anatomical channels (T1, T2, and proton density weighted), diffusion-related channels (fractional anisotropy, mean diffusivity, longitudinal diffusivity, mean diffusion-weighted image), tissue channels (CSF probability, gray matter probability, white matter probability, tissue labels), and two cortical parcellation maps. The SRI24 atlas enables multi-channel atlas-to-subject image registration. It is uniquely versatile in that it is equally suited for the two fundamentally different atlas applications: label propagation and spatial normalization. Label propagation, herein demonstrated using DTI fiber tracking, is enabled by the increased sharpness of the SRI24 atlas compared with other available atlases. Spatial normalization, herein demonstrated using data from a young-old group comparison study, is enabled by its unbiased average population shape property. For both propagation and normalization, we also report the results of quantitative comparisons with seven other published atlases: Colin27, MNI152, ICBM452 (warp5 and air12), and LPBA40 (SPM5, FLIRT, AIR). Our results suggest that the SRI24 atlas, although based on 3T MR data, allows equally accurate spatial normalization of data acquired at 1.5T as the comparison atlases, all of which are based on 1.5T data. Furthermore, the SRI24 atlas is as suitable for label propagation as the comparison atlases and detailed enough to allow delineation of anatomical structures for this purpose directly in the atlas. PMID:20017133

  10. Multi-Channel Seismic Images of the Mariana Forearc: EW0202 Initial Results

    NASA Astrophysics Data System (ADS)

    Oakley, A. J.; Goodliffe, A. M.; Taylor, B.; Moore, G. F.; Fryer, P.

    2002-12-01

    During the Spring of 2002, the Mariana Subduction Factory was surveyed using multi-channel seismics (MCS) as the first major phase of a US-Japanese collaborative NSF-MARGINS funded project. The resulting geophysical transects extend from the Pacific Plate to the West Mariana remnant arc. For details of this survey, including the results from the back-arc, refer to Taylor et al. (this session). The incoming Pacific Plate and its accompanying seamounts are deformed by plate flexure, resulting in extension of the upper crust as it enters the subduction zone. The resultant trench parallel faults dominate the bathymetry and MCS data. Beneath the forearc, in the southern transects near Saipan, the subducting slab is imaged to a distance of 50-60 km arcward. In addition to ubiquitous trench parallel normal faulting, a N-S transect of the forearc clearly shows normal faults perpendicular to the trench resulting from N-S extension. On the east side of the Mariana Ridge, thick sediment packages extend into the forearc. Directly east of Saipan and Tinian, a large, deeply scouring slide mass is imaged. Several serpentine mud volcanoes (Big Blue, Turquoise and Celestial) were imaged on the Mariana Forearc. Deep horizontal reflectors (likely original forearc crust) are imaged under the flanks of some of these seamounts. A possible "throat" reflector is resolved on multiple profiles at the summit of Big Blue, the northern-most seamount in the study area. The flanks of Turquoise seamount terminate in toe thrusts that represent uplift and rotation of surrounding sediments as the volcano grows outward. These thrusts form a basal ridge around the seamount similar to that previously noted encircling Conical Seamount. Furthermore, MCS data has revealed that some forearc highs previously thought to be fault blocks are in actuality mud volcanoes.

  11. Smart multi-channel two-dimensional micro-gas chromatography for rapid workplace hazardous volatile organic compounds measurement.

    PubMed

    Liu, Jing; Seo, Jung Hwan; Li, Yubo; Chen, Di; Kurabayashi, Katsuo; Fan, Xudong

    2013-03-01

    We developed a novel smart multi-channel two-dimensional (2-D) micro-gas chromatography (μGC) architecture that shows promise to significantly improve 2-D μGC performance. In the smart μGC design, a non-destructive on-column gas detector and a flow routing system are installed between the first dimensional separation column and multiple second dimensional separation columns. The effluent from the first dimensional column is monitored in real-time and decision is then made to route the effluent to one of the second dimensional columns for further separation. As compared to the conventional 2-D μGC, the greatest benefit of the smart multi-channel 2-D μGC architecture is the enhanced separation capability of the second dimensional column and hence the overall 2-D GC performance. All the second dimensional columns are independent of each other, and their coating, length, flow rate and temperature can be customized for best separation results. In particular, there is no more constraint on the upper limit of the second dimensional column length and separation time in our architecture. Such flexibility is critical when long second dimensional separation is needed for optimal gas analysis. In addition, the smart μGC is advantageous in terms of elimination of the power intensive thermal modulator, higher peak amplitude enhancement, simplified 2-D chromatogram re-construction and potential scalability to higher dimensional separation. In this paper, we first constructed a complete smart 1 × 2 channel 2-D μGC system, along with an algorithm for automated control/operation of the system. We then characterized and optimized this μGC system, and finally employed it in two important applications that highlight its uniqueness and advantages, i.e., analysis of 31 workplace hazardous volatile organic compounds, and rapid detection and identification of target gas analytes from interference background. PMID:23303462

  12. The detection and location of low magnitude earthquakes in northern Norway using multi-channel waveform correlation at regional distances

    NASA Astrophysics Data System (ADS)

    Gibbons, Steven J.; Bøttger Sørensen, Mathilde; Harris, David B.; Ringdal, Frode

    2007-03-01

    A fortuitous sequence of closely spaced earthquakes in the Rana region of northern Norway, during 2005, has provided an ideal natural laboratory for investigating event detectability using waveform correlation over networks and arrays at regional distances. A small number of events between magnitude 2.0 and 3.5 were recorded with a high SNR by the Fennoscandian IMS seismic arrays at distances over 600 km and three of these events, including the largest on 24 June, displayed remarkable waveform similarity even at relatively high frequencies. In an effort to detect occurrences of smaller earthquakes in the immediate geographical vicinity of the 24 June event, a multi-channel correlation detector for the NORSAR array was run for the whole calender year 2005 using the signal from the master event as a template. A total of 32 detections were made and all but 2 of these coincided with independent correlation detections using the other Nordic IMS array stations; very few correspond to signals detectable using traditional energy detectors. Permanent and temporary stations of the Norwegian National Seismic Network (NNSN) at far closer epicentral distances have confirmed that all but one of the correlation detections at NORSAR in fact correspond to real events. The closest stations at distances of approximately 10 km can confirm that the smallest of these events have magnitudes down to 0.5 which represents a detection threshold reduction of over 1.5 for the large-aperture NORSAR array and over 1.0 for the almost equidistant regional ARCES array. The incompleteness of the local network recordings precludes a comprehensive double-difference location for the full set of events. However, stable double-difference relative locations can be obtained for eight of the events using only the Lg phase recorded at the array stations. All events appear to be separated by less than 0.5 km. Clear peaks were observed in the NORSAR correlation coefficient traces during the coda of some of the

  13. Single and Multi-channel Quantum Dragons from Rectangular Nanotubes

    NASA Astrophysics Data System (ADS)

    Li, Zhou; Novotny, Mark

    2015-03-01

    Recently quantum dragons have been discovered theoretically. Quantum dragons are nanostructures with correlated disorder that permit energy-independent total quantum transmission of electrons. Hence the electrical conductance G in a two-terminal measurement should be the conductance quantum G0 = 2e2 / h . The single-band tight banding model is used. An example of a single-channel quantum dragon is a rectangular nanotube with disorder along the direction z of the electron propagation. Quantum dragons are obtained by solving the time-independent Schrödinger equation to obtain the electrical transmission calT as a function of the incoming electron energy E. A quantum dragon has calT (E) =1 for all energies. This work generalizes the solution of the time-independent Schrödinger equation to the case of more than one open channel, and applies the method to nanotubes formed from rectangular lattices. One can envision such single-walled rectangular nanotubes for iron starting from free-standing single-atom-thick Fe membranes which have recently been obtained experimentally. Supported in part by NSF Grant DMR-1206233.

  14. Multi-channel Kalman filters for active noise control.

    PubMed

    van Ophem, S; Berkhoff, A P

    2013-04-01

    By formulating the feed-forward broadband active noise control problem as a state estimation problem it is possible to achieve a faster rate of convergence than the filtered reference least mean squares algorithm and possibly also a better tracking performance. A multiple input/multiple output Kalman algorithm is derived to perform this state estimation. To make the algorithm more suitable for real-time applications, the Kalman filter is written in a fast array form and the secondary path state matrices are implemented in output normal form. The resulting filter implementation is tested in simulations and in real-time experiments. It was found that for a constant primary path the filter has a fast rate of convergence and is able to track changes in the frequency spectrum. For a forgetting factor equal to unity the system is robust but the filter is unable to track rapid changes in the primary path. A forgetting factor lower than 1 gives a significantly improved tracking performance but leads to a numerical instability for the fast array form of the algorithm. PMID:23556580

  15. Multi-channel Scaler Cards Improve Data Collection

    NASA Technical Reports Server (NTRS)

    2004-01-01

    Scientists interested in exploring the intricacies and dynamics of Earth's climate and ecosystems continually need smaller, lighter instrumentation that can be placed onboard various sensing platforms, such as Unmanned Aerial Vehicles (UAVs). Responding to a need for improved data collection for remote atmospheric measurement systems, ASRC Aerospace Corporation, of Greenbelt, Maryland, developed a series of low-power, highly integrated, multichannel scaler (MCS) cards. The cards were designed to meet the needs of NASA's ground-based and airborne Light Detection and Ranging (LIDAR) photoncounting programs. They can rapidly collect thousands of data points during a continuous scan of the atmosphere.

  16. A multi-channel tunable source for atomic sensors

    NASA Astrophysics Data System (ADS)

    Bigelow, Matthew S.; Roberts, Tony D.; McNeil, Shirley A.; Hawthorne, Todd; Battle, Phil

    2015-09-01

    We have designed and completed initial testing on a laser source suitable for atomic interferometry from compact, robust, integrated components. Our design is enabled by capitalizing on robust, well-commercialized, low-noise telecom components with high reliability and declining costs which will help to drive the widespread deployment of this system. The key innovation is the combination of current telecom-based fiber laser and modulator technology with periodicallypoled waveguide technology to produce tunable laser light at rubidium D1 and D2 wavelengths (and expandable to other alkalis) using second harmonic generation (SHG). Unlike direct-diode sources, this source is immune to feedback at the Rb line eliminating the need for bulky high-power isolators in the system. In addition, the source has GHz-level frequency agility and in our experiments was found to only be limited by the agility of our RF generator. As a proof-of principle, the source was scanned through the Doppler-broadened Rb D2 absorption line. With this technology, multiple channels can be independently tuned to produce the fields needed for addressing atomic states in atom interferometers and clocks. Thus, this technology could be useful in the development cold-atom inertial sensors and gyroscopes.

  17. Multi-channel millimeter wave image registration and segmentation for concealed object detection

    NASA Astrophysics Data System (ADS)

    Lee, Dong-Su; Yeom, Seokwon; Son, Jung-Young; Kim, Shin-Hwan

    2010-04-01

    We address an image registration and segmentation method to detect concealed objects captured by passive millimeter wave (MMW) imaging. Passive MMW imaging can create interpretable imagery on the objects concealed under clothing. Due to the penetrating property of the MMW imaging, the MMW imaging system is often employed for the security and defense system. In this paper, we utilize a multi-channel PMMW imaging system operating at the 8 mm regime with linear polarization. Image registration and segmentation are performed to detect concealed objects under clothing. The registration is preceded to align different channel images by means of geometric feature extraction and a matching process. The Linde-Buzo-Gray (LBG) vector quantization with multi-channel information is adopted to segment the concealed object from the body area. In the experiment, the automated image registration and segmentation are performed with various concealed objects including a metal axe and a liquid container.

  18. Characterizing phantom arteries with multi-channel laser ultrasonics and photo-acoustics.

    PubMed

    Johnson, Jami L; van Wijk, Kasper; Sabick, Michelle

    2014-03-01

    Multi-channel photo-acoustic and laser ultrasonic waves are used to sense the characteristics of proxies for healthy and diseased vessels. The acquisition system is non-contacting and non-invasive with a pulsed laser source and a laser vibrometer detector. As the wave signatures of our targets are typically low in amplitude, we exploit multi-channel acquisition and processing techniques. These are commonly used in seismology to improve the signal-to-noise ratio of data. We identify vessel proxies with a diameter on the order of 1 mm, at a depth of 18 mm. Variations in scattered and photo-acoustic signatures are related to differences in vessel wall properties and content. The methods described have the potential to improve imaging and better inform interventions for atherosclerotic vessels, such as the carotid artery. PMID:24412169

  19. Method of multi-channel data readout and acquisition

    DOEpatents

    Degtiarenko, Pavel V.; Popov, Vladimir E.

    2010-06-15

    A method for dealing with the problem of simultaneous continuous readout of large number of data channels from the set of multiple sensors in instances where the use of multiple amplitude-to-digital converters is not practical or causes undesirable extra noise and distortion in the data. The new method uses sensor front-end s and subsequent electronics to transform the analog input signals and encode them into a series of short pulses that can be transmitted to a long distance via a high frequency transmission line without information loss. Upon arrival at a destination data decoder and analyzer device, the series of short pulses can be decoded and transformed back, to obtain, store, and utilize the sensor information with the required accuracy.

  20. A robotic multi-channel platform for interstitial photodynamic therapy

    NASA Astrophysics Data System (ADS)

    Sharikova, Anna V.; Finlay, Jarod C.; Dimofte, Andreea; Zhu, Timothy C.

    2013-03-01

    A custom-made robotic multichannel platform for interstitial photodynamic therapy (PDT) and diffuse optical tomography (DOT) was developed and tested in a phantom experiment. The system, which was compatible with the operating room (OR) environment, had 16 channels for independent positioning of light sources and/or isotropic detectors in separate catheters. Each channel's motor had an optical encoder for position feedback, with resolution of 0.05 mm, and a maximum speed of 5 cm/s. Automatic calibration of detector positions was implemented using an optical diode beam that defined the starting position of each motor, and by means of feedback algorithms controlling individual channels. As a result, the accuracy of zero position of 0.1 mm for all channels was achieved. We have also employed scanning procedures where detectors automatically covered the appropriate range around source positions. Thus, total scan time for a typical optical properties (OP) measurement throughout the phantom was about 1.5 minutes with point sources. The OP were determined based on the measured light fluence rates. These enhancements allow a tremendous improvement of treatment quality for a bulk tumor compared to the systems employed in previous clinical trials.

  1. Avian embryo monitoring during incubation using multi-channel diffuse speckle contrast analysis.

    PubMed

    Yeo, Chaebeom; Park, Hyun-Cheol; Lee, Kijoon; Song, Cheol

    2016-01-01

    Determining the survival rate of avian embryos during incubation is essential for cost-saving in the poultry industry. A multi-channel diffuse speckle contrast analysis (DSCA) system, comprising four optical fiber channels, is proposed to achieve noninvasive in vivo measurements of deep tissue flow. The system was able to monitor chick embryo vital signs over the entire incubation period. Moreover, it proved useful in distinguishing between chick embryos in healthy and weakened conditions. PMID:26819820

  2. Multi-Channel Electronically Scanned Cryogenic Pressure Sensor And Method For Making Same

    NASA Technical Reports Server (NTRS)

    Chapman, John J. (Inventor); Hopson, Purnell, Jr. (Inventor); Holloway, Nancy M. (Inventor)

    2001-01-01

    A miniature, multi-channel, electronically scanned pressure measuring device uses electrostatically bonded silicon dies in a multi-element array. These dies are bonded at specific sites on a glass, pre-patterned substrate. Thermal data is multiplexed and recorded on each individual pressure measuring diaphragm. The device functions in a cryogenic environment without the need of heaters to keep the sensor at constant temperatures.

  3. Avian embryo monitoring during incubation using multi-channel diffuse speckle contrast analysis

    PubMed Central

    Yeo, Chaebeom; Park, Hyun-cheol; Lee, Kijoon; Song, Cheol

    2015-01-01

    Determining the survival rate of avian embryos during incubation is essential for cost-saving in the poultry industry. A multi-channel diffuse speckle contrast analysis (DSCA) system, comprising four optical fiber channels, is proposed to achieve noninvasive in vivo measurements of deep tissue flow. The system was able to monitor chick embryo vital signs over the entire incubation period. Moreover, it proved useful in distinguishing between chick embryos in healthy and weakened conditions. PMID:26819820

  4. Estimating neugebauer primaries for multi-channel spectral printing modeling

    NASA Astrophysics Data System (ADS)

    Slavuj, Radovan; Coppel, Ludovic G.; Olen, Melissa; Hardeberg, Jon Yngve

    2014-02-01

    Multichannel printer modeling has been an active area of research in the field of spectral printing. The most commonly used models for characterization of such systems are the spectral Neugebauer (SN) and its extensions. This work addresses issues that can arise during calibration and testing of the SN model when modelling a 7-colorant printer. Since most substrates are limited in their capacity to take in large amount of ink, it is not always possible to print all colorant combinations necessary to determine the Neugebauer primaries (NP). A common solution is to estimate the nonprintable Neugebauer primaries from the single colorant primaries using the Kubelka-Munk (KM) optical model. In this work we test whether a better estimate can be obtained using general radiative transfer theory, which better represents the angular variation of the reflectance from highly absorbing media, and takes surface scattering into account. For this purpose we use the DORT2002 model. We conclude DORT2002 does not offer significant improvements over KM in the estimation of the NPs, but a significant improvement is obtained when using a simple surface scattering model. When the estimated primaries are used as inputs to the SN model instead of measured ones, it is found the SN model performs the same or better in terms of color difference and spectral error. If the mixed measured and estimated primaries are used as inputs to the SN model, it performs better than using either measured or estimated.

  5. The SRI24 Multi-Channel Brain Atlas

    PubMed Central

    Rohlfing, Torsten; Zahr, Natalie M.; Sullivan, Edith V.; Pfefferbaum, Adolf

    2009-01-01

    We present a new standard atlas of the human brain based on magnetic resonance images. The atlas was generated using unbiased population registration from high-resolution images obtained by multichannel-coil acquisition at 3T in a group of 24 normal subjects. The final atlas comprises three anatomical channels (T1-weighted, early and late spin echo), three diffusion-related channels (fractional anisotropy, mean diffusivity, diffusion-weighted image), and three tissue probability maps (CSF, gray matter, white matter). The atlas is dynamic in that it is implicitly represented by nonrigid transformations between the 24 subject images, as well as distortion-correction alignments between the image channels in each subject. The atlas can, therefore, be generated at essentially arbitrary image resolutions and orientations (e.g., AC/PC aligned), without compounding interpolation artifacts. We demonstrate in this paper two different applications of the atlas: (a) region definition by label propagation in a fiber tracking study is enabled by the increased sharpness of our atlas compared with other available atlases, and (b) spatial normalization is enabled by its average shape property. In summary, our atlas has unique features and will be made available to the scientific community as a resource and reference system for future imaging-based studies of the human brain. PMID:19183706

  6. PMT connectors for multi-channel film waveguides

    NASA Astrophysics Data System (ADS)

    Hatakeyama, Yutaka; Imamura, Saburo; Kobayashi, Junya; Takahara, Hideyuki

    2009-02-01

    Intensive research on optical interconnections has attracted considerable attention for high-end router and server applications. A polymer film waveguide is expected to be applied to an optical circuit board in an optical interconnection. The film waveguide requires a conventional connector if it is to be employed as a practical optical circuit board. This paper describes the MT connector used with polymer film waveguide (PMT connector), which is compatible with the MT connector used with optical fiber. This connector can be attached to a film waveguide by passive alignment, and is used to connect waveguides. When the connector was equipped with an epoxy resin film waveguide, the insertion and connection losses were less than 1.4 and 0.5 dB, respectively. These losses are sufficiently small to meet the basic requirement for optical circuit boards, so we were able to fabricate a flexible optical circuit board with PMT connectors. This paper also describes the application of a film waveguide with PMT connectors to an optical front plane system.

  7. Progress in multi-channel image fusion for face image matching

    NASA Astrophysics Data System (ADS)

    DelMarco, Stephen

    2013-05-01

    Fusion techniques have proven to be very useful for many signal and image processing applications including image recognition, image registration, and biometric matching. Along with standard fusion techniques, hypercomplex image processing techniques have been developed recently. These techniques represent a form of image fusion in which several image components are combined to form a multi-channel image. The multi-channel imagery may be processed using hypercomplex transforms, such as the hypercomplex Fourier transform, for image matching and registration. In this paper we investigate performance of multi-channel image fusion for face image matching. We use 3-D color face imagery and investigate fusion of various combinations of grayscale intensity, color, and range information. We conduct a theoretical investigation to identify conditions under which matchers using image channel fusion provide superior matching performance relative to matchers fusing single channel image matching results. We present numerical performance results in the form of Receiver Operating Characteristics curves quantifying matching performance for verification hypothesis testing problems.

  8. Load-Adaptive Practical Multi-Channel Communications in Wireless Sensor Networks

    PubMed Central

    Islam, Md. Shariful; Alam, Muhammad Mahbub; Hong, Choong Seon; Lee, Sungwon

    2010-01-01

    In recent years, a significant number of sensor node prototypes have been designed that provide communications in multiple channels. This multi-channel feature can be effectively exploited to increase the overall capacity and performance of wireless sensor networks (WSNs). In this paper, we present a multi-channel communications system for WSNs that is referred to as load-adaptive practical multi-channel communications (LPMC). LPMC estimates the active load of a channel at the sink since it has a more comprehensive view of the network behavior, and dynamically adds or removes channels based on the estimated load. LPMC updates the routing path to balance the loads of the channels. The nodes in a path use the same channel; therefore, they do not need to switch channels to receive or forward packets. LPMC has been evaluated through extensive simulations, and the results demonstrate that it can effectively increase the delivery ratio, network throughput, and channel utilization, and that it can decrease the end-to-end delay and energy consumption. PMID:22163685

  9. Load-adaptive practical multi-channel communications in wireless sensor networks.

    PubMed

    Islam, Md Shariful; Alam, Muhammad Mahbub; Hong, Choong Seon; Lee, Sungwon

    2010-01-01

    In recent years, a significant number of sensor node prototypes have been designed that provide communications in multiple channels. This multi-channel feature can be effectively exploited to increase the overall capacity and performance of wireless sensor networks (WSNs). In this paper, we present a multi-channel communications system for WSNs that is referred to as load-adaptive practical multi-channel communications (LPMC). LPMC estimates the active load of a channel at the sink since it has a more comprehensive view of the network behavior, and dynamically adds or removes channels based on the estimated load. LPMC updates the routing path to balance the loads of the channels. The nodes in a path use the same channel; therefore, they do not need to switch channels to receive or forward packets. LPMC has been evaluated through extensive simulations, and the results demonstrate that it can effectively increase the delivery ratio, network throughput, and channel utilization, and that it can decrease the end-to-end delay and energy consumption. PMID:22163685

  10. Development of refined MCNPX-PARET multi-channel model for transient analysis in research reactors

    SciTech Connect

    Kalcheva, S.; Koonen, E.; Olson, A. P.

    2012-07-01

    Reactivity insertion transients are often analyzed (RELAP, PARET) using a two-channel model, representing the hot assembly with specified power distribution and an average assembly representing the remainder of the core. For the analysis of protected by the reactor safety system transients and zero reactivity feedback coefficients this approximation proves to give adequate results. However, a more refined multi-channel model representing the various assemblies, coupled through the reactivity feedback effects to the whole reactor core is needed for the analysis of unprotected transients with excluded over power and period trips. In the present paper a detailed multi-channel PARET model has been developed which describes the reactor core in different clusters representing typical BR2 fuel assemblies. The distribution of power and reactivity feedback in each cluster of the reactor core is obtained from a best-estimate MCNPX calculation using the whole core geometry model of the BR2 reactor. The sensitivity of the reactor response to power, temperature and energy distributions is studied for protected and unprotected reactivity insertion transients, with zero and non-zero reactivity feedback coefficients. The detailed multi-channel model is compared vs. simplified fewer-channel models. The sensitivities of transient characteristics derived from the different models are tested on a few reactivity insertion transients with reactivity feedback from coolant temperature and density change. (authors)

  11. The multi-channel cochlear implant: past, present and future perspectives.

    PubMed

    Clark, Graeme

    2009-01-01

    Initial research demonstrated that only low frequencies could be mimicked with rate of electrical stimulation, and thus multi-channel rather than single-channel stimulation was required for the place coding of the mid-high speech frequencies. Place coding of mid-high frequencies was best achieved with electrodes inside the cochlea. Furthermore, correct biomechanical properties of a multiple electrode bundle were required for it to pass around the cochlear spiral to the speech frequency region. Biological studies showed too that intra-cochlear electrodes could be used with minimal trauma, safe electrical stimulus parameters, and methods to prevent inner ear infection and meningitis. The crucial discoveries for coding speech with electrical stimulation have been based on the discovery of: 1) the fact the brain processes frequency information along spatial and temporal channels, and 2) that the first patient experienced vowels when stimulating different electrodes that corresponded to the place of excitation for single formant vowels in people with normal hearing. The inaugural and subsequent speech processing strategies extracted frequencies of special importance for speech intelligibility, and transmitted the information along place coding channels. The voicing frequency and/or amplitude, was coded as temporal information across these spatial channels. As a result a great majority of severely-to-profoundly deaf people with previous hearing can not only communicate when electrical stimulation is combined with lipreading, but with electrical stimulation alone. In addition, the benefits of binaural hearing with bilateral cochlear implants or an implant in one ear and hearing aid in the other ear have been realized. Related psychophysical research has discovered the basic perceptual skills that process the complex patterns of brain excitation that underlie speech recognition both in the one ear as well as bilateral implants.In addition the development of the perceptual

  12. Nonlocal atlas-guided multi-channel forest learning for human brain labeling

    PubMed Central

    Ma, Guangkai; Gao, Yaozong; Wu, Guorong; Wu, Ligang; Shen, Dinggang

    2016-01-01

    Purpose: It is important for many quantitative brain studies to label meaningful anatomical regions in MR brain images. However, due to high complexity of brain structures and ambiguous boundaries between different anatomical regions, the anatomical labeling of MR brain images is still quite a challenging task. In many existing label fusion methods, appearance information is widely used. However, since local anatomy in the human brain is often complex, the appearance information alone is limited in characterizing each image point, especially for identifying the same anatomical structure across different subjects. Recent progress in computer vision suggests that the context features can be very useful in identifying an object from a complex scene. In light of this, the authors propose a novel learning-based label fusion method by using both low-level appearance features (computed from the target image) and high-level context features (computed from warped atlases or tentative labeling maps of the target image). Methods: In particular, the authors employ a multi-channel random forest to learn the nonlinear relationship between these hybrid features and target labels (i.e., corresponding to certain anatomical structures). Specifically, at each of the iterations, the random forest will output tentative labeling maps of the target image, from which the authors compute spatial label context features and then use in combination with original appearance features of the target image to refine the labeling. Moreover, to accommodate the high inter-subject variations, the authors further extend their learning-based label fusion to a multi-atlas scenario, i.e., they train a random forest for each atlas and then obtain the final labeling result according to the consensus of results from all atlases. Results: The authors have comprehensively evaluated their method on both public LONI_LBPA40 and IXI datasets. To quantitatively evaluate the labeling accuracy, the authors use the

  13. Corona discharge radical emission spectroscopy: a multi-channel detector with nose-type function for discrimination analysis.

    PubMed

    Tian, Yunfei; Wu, Peng; Wu, Xi; Jiang, Xiaoming; Xu, Kailai; Hou, Xiandeng

    2013-04-21

    A simple and economical multi-channel optical sensor using corona discharge radical emission spectroscopy is developed and explored as an optical nose for discrimination analysis of volatile organic compounds, wines, and even isomers. PMID:23471437

  14. The Use of Continuous Wavelet Transform Based on the Fast Fourier Transform in the Analysis of Multi-channel Electrogastrography Recordings.

    PubMed

    Komorowski, Dariusz; Pietraszek, Stanislaw

    2016-01-01

    This paper presents the analysis of multi-channel electrogastrographic (EGG) signals using the continuous wavelet transform based on the fast Fourier transform (CWTFT). The EGG analysis was based on the determination of the several signal parameters such as dominant frequency (DF), dominant power (DP) and index of normogastria (NI). The use of continuous wavelet transform (CWT) allows for better visible localization of the frequency components in the analyzed signals, than commonly used short-time Fourier transform (STFT). Such an analysis is possible by means of a variable width window, which corresponds to the scale time of observation (analysis). Wavelet analysis allows using long time windows when we need more precise low-frequency information, and shorter when we need high frequency information. Since the classic CWT transform requires considerable computing power and time, especially while applying it to the analysis of long signals, the authors used the CWT analysis based on the fast Fourier transform (FFT). The CWT was obtained using properties of the circular convolution to improve the speed of calculation. This method allows to obtain results for relatively long records of EGG in a fairly short time, much faster than using the classical methods based on running spectrum analysis (RSA). In this study authors indicate the possibility of a parametric analysis of EGG signals using continuous wavelet transform which is the completely new solution. The results obtained with the described method are shown in the example of an analysis of four-channel EGG recordings, performed for a non-caloric meal. PMID:26573647

  15. Multi-channel programmable power supply with temperature compensation for silicon sensors

    NASA Astrophysics Data System (ADS)

    Shukla, R. A.; Achanta, V. G.; Dugad, S. R.; Freeman, J.; Garde, C. S.; Gupta, S. K.; Khandekar, P. D.; Kurup, A. M.; Lokhandwala, S. S.; Los, S.; Prabhu, S. S.; Rakshe, P. S.

    2016-01-01

    Silicon Photo-Multipliers (SiPMs) are increasingly becoming popular for discrete photon counting applications due to the wealth of advantages they offer over conventional photo-detectors such as photo-multiplier tubes and hybrid photo-diodes. SiPMs are used in variety of applications ranging from high energy physics and nuclear physics experiments to medical diagnostics. The gain of a SiPM is directly proportional to the difference between applied and breakdown voltage of the device. However, the breakdown voltage depends critically on the ambient temperature and has a large temperature co-efficient in the range of 40-60 mV/°C resulting in a typical gain variation of 3%-5%/°C [Dinu et al., in IEEE Nuclear Science Symposium, Medical Imaging Conference and 17th Room Temperature Semiconductor Detector Workshop (IEEE, 2010), p. 215]. We plan to use the SiPM as a replacement for PMT in the cosmic ray experiment (GRAPES-3) at Ooty [Gupta et al., Nucl. Instrum. Methods Phys. Res., Sect. A 540, 311 (2005)]. There the SiPMs will be operated in an outdoor environment subjected to temperature variation of about 15 °C over a day. A gain variation of more than 50% was observed for such large variations in the temperature. To stabilize the gain of the SiPM under such operating conditions, a low-cost, multi-channel programmable power supply (0-90 V) was designed that simultaneously provides the bias voltage to 16 SiPMs. The programmable power supply (PPS) was designed to automatically adjust the operating voltage for each channel with a built-in closed loop temperature feedback mechanism. The PPS provides bias voltage with a precision of 6 mV and measures the load current with a precision of 1 nA. Using this PPS, a gain stability of 0.5% for SiPM (Hamamatsu, S10931-050P) has been demonstrated over a wide temperature range of 15 °C. The design methodology of the PPS system, its validation, and the results of the tests carried out on the SiPM is presented in this article. The

  16. Simulation-Based Validation for Four-Dimensional Multi-Channel Ultrasound Current Source Density Imaging

    PubMed Central

    Wang, Zhaohui; Witte, Russell S.

    2015-01-01

    Ultrasound current source density imaging (UCSDI), which has application to the heart and brain, exploits the acoustoelectric (AE) effect and Ohm's law to detect and map an electrical current distribution. In this study, we describe 4-D UCSDI simulations of a dipole field for comparison and validation with bench-top experiments. The simulations consider the properties of the ultrasound pulse as it passes through a conductive medium, the electric field of the injected dipole, and the lead field of the detectors. In the simulation, the lead fields of detectors and electric field of the dipole were calculated by the finite element (FE) method, and the convolution and correlation in the computation of the detected AE voltage signal were accelerated using 3-D fast Fourier transforms. In the bench-top experiment, an electric dipole was produced in a bath of 0.9% NaCl solution containing two electrodes, which injected an ac pulse (200 Hz, 3 cycles) ranging from 0 to 140 mA. Stimulating and recording electrodes were placed in a custom electrode chamber made on a rapid prototype printer. Each electrode could be positioned anywhere on an x-y grid (5 mm spacing) and individually adjusted in the depth direction for precise control of the geometry of the current sources and detecting electrodes. A 1-MHz ultrasound beam was pulsed and focused through a plastic film to modulate the current distribution inside the saline-filled tank. AE signals were simultaneously detected at a sampling frequency of 15 MHz on multiple recording electrodes. A single recording electrode is sufficient to form volume images of the current flow and electric potentials. The AE potential is sensitive to the distance from the dipole, but is less sensitive to the angle between the detector and the dipole. Multi-channel UCSDI potentially improves 4-D mapping of bioelectric sources in the body at high spatial resolution, which is especially important for diagnosing and guiding treatment of cardiac and

  17. Simulation-based validation for four- dimensional multi-channel ultrasound current source density imaging.

    PubMed

    Wang, Zhaohui; Witte, Russell S

    2014-03-01

    Ultrasound current source density imaging (UCSDI), which has application to the heart and brain, exploits the acoustoelectric (AE) effect and Ohm's law to detect and map an electrical current distribution. In this study, we describe 4-D UCSDI simulations of a dipole field for comparison and validation with bench-top experiments. The simulations consider the properties of the ultrasound pulse as it passes through a conductive medium, the electric field of the injected dipole, and the lead field of the detectors. In the simulation, the lead fields of detectors and electric field of the dipole were calculated by the finite element (FE) method, and the convolution and correlation in the computation of the detected AE voltage signal were accelerated using 3-D fast Fourier transforms. In the bench-top experiment, an electric dipole was produced in a bath of 0.9% NaCl solution containing two electrodes, which injected an ac pulse (200 Hz, 3 cycles) ranging from 0 to 140 mA. Stimulating and recording electrodes were placed in a custom electrode chamber made on a rapid prototype printer. Each electrode could be positioned anywhere on an x-y grid (5 mm spacing) and individually adjusted in the depth direction for precise control of the geometry of the current sources and detecting electrodes. A 1-MHz ultrasound beam was pulsed and focused through a plastic film to modulate the current distribution inside the saline-filled tank. AE signals were simultaneously detected at a sampling frequency of 15 MHz on multiple recording electrodes. A single recording electrode is sufficient to form volume images of the current flow and electric potentials. The AE potential is sensitive to the distance from the dipole, but is less sensitive to the angle between the detector and the dipole. Multi-channel UCSDI potentially improves 4-D mapping of bioelectric sources in the body at high spatial resolution, which is especially important for diagnosing and guiding treatment of cardiac and

  18. Multi-channel programmable power supply with temperature compensation for silicon sensors.

    PubMed

    Shukla, R A; Achanta, V G; Dugad, S R; Freeman, J; Garde, C S; Gupta, S K; Khandekar, P D; Kurup, A M; Lokhandwala, S S; Los, S; Prabhu, S S; Rakshe, P S

    2016-01-01

    Silicon Photo-Multipliers (SiPMs) are increasingly becoming popular for discrete photon counting applications due to the wealth of advantages they offer over conventional photo-detectors such as photo-multiplier tubes and hybrid photo-diodes. SiPMs are used in variety of applications ranging from high energy physics and nuclear physics experiments to medical diagnostics. The gain of a SiPM is directly proportional to the difference between applied and breakdown voltage of the device. However, the breakdown voltage depends critically on the ambient temperature and has a large temperature co-efficient in the range of 40-60 mV/°C resulting in a typical gain variation of 3%-5%/°C [Dinu et al., in IEEE Nuclear Science Symposium, Medical Imaging Conference and 17th Room Temperature Semiconductor Detector Workshop (IEEE, 2010), p. 215]. We plan to use the SiPM as a replacement for PMT in the cosmic ray experiment (GRAPES-3) at Ooty [Gupta et al., Nucl. Instrum. Methods Phys. Res., Sect. A 540, 311 (2005)]. There the SiPMs will be operated in an outdoor environment subjected to temperature variation of about 15 °C over a day. A gain variation of more than 50% was observed for such large variations in the temperature. To stabilize the gain of the SiPM under such operating conditions, a low-cost, multi-channel programmable power supply (0-90 V) was designed that simultaneously provides the bias voltage to 16 SiPMs. The programmable power supply (PPS) was designed to automatically adjust the operating voltage for each channel with a built-in closed loop temperature feedback mechanism. The PPS provides bias voltage with a precision of 6 mV and measures the load current with a precision of 1 nA. Using this PPS, a gain stability of 0.5% for SiPM (Hamamatsu, S10931-050P) has been demonstrated over a wide temperature range of 15 °C. The design methodology of the PPS system, its validation, and the results of the tests carried out on the SiPM is presented in this

  19. Note: Design principles of a linear array multi-channel effusive metal-vapor atom source

    SciTech Connect

    Jana, B.; Majumder, A.; Thakur, K. B.; Das, A. K.

    2013-10-15

    Atomic beams can easily be produced by allowing atoms to effuse through a channel. In an earlier investigation [A. Majumder et al., Vacuum 83, 989 (2009)], we had designed, fabricated, and characterized an effusive metal-vapor source using collinear-array of multi-channel. In this note, we describe the theoretical basis of designing the source. Atom density in atomic beam has been estimated using a set of analytical expressions for long-channel operated in transparent mode. Parametric studies on aspect ratio of channel, inter-channel separation, beam width, and vertical distance from the source are carried out. They are useful in providing physical picture and optimizing design parameters.

  20. Note: An underwater multi-channel plasma array for water sterilization

    NASA Astrophysics Data System (ADS)

    Yang, Y.; Kim, H.; Starikovskiy, A.; Cho, Y. I.; Fridman, A.

    2011-09-01

    A simple yet effective method to generate multi-channel plasma array in water is presented in this paper. Thin circular metal disks sandwiched between dielectric layers were used, allowing the production of large-volume underwater plasma array with higher stability. The system can be further scaled up by stacking multiple metal disks, making it suitable for large-scale industrial water treatment. Generation of UV and reactive species was identified by optical emission spectroscopy. Sterilization experiments were performed. Results show that the device was effective in deactivating E. coli in water over a wide range of initial concentrations ranging from 104 to 108 CFU/ml.

  1. Pre-experiment testing of the Multi Channel Systems 16-channel preamplifier CPA16

    SciTech Connect

    Patin, J B; Stoyer, M A; Moody, K J; Friensehner, A V

    2003-11-03

    The 16-channel preamplifier model CPA16 from Multi Channel Systems was studied. The CPA16 preamplifier/amplifier module is a candidate to be used as the preamplifiers and amplifiers for the focal plane detectors of the Mass Analyzer of Super Heavy Atoms (MASHA). The equipment used to test the CPA16, the results of testing the CPA16 with a pulser, a mixed {sup 229}Th/{sup 148}Gd source and a {sup 252}Cf source, and a summary of the results will be presented.

  2. The Crustal Structure of the Northern South China Sea continental margin revealed by Multi-Channel Seismic Reflection and Ocean Bottom Seismometer Observations

    NASA Astrophysics Data System (ADS)

    Wang, Hao; Chao Huang, I.; Shine Liu, Char; Chang, Emmy T. Y.

    2015-04-01

    The South China Sea (SCS) is an ideal place to examine the nature of continental rifting, break-up, and the onset of seafloor spreading. Being mostly inactive today, the SCS basin is measured to get spreading in the early Oligocene and to generate a series of syn-rift structures on the margins, therefore, to know the crustal structures of continental margin can help us to understand the evolution of the SCS. In this study, we use multi-channel seismic (MCS) reflection data to reveal the upper crustal structures and ocean bottom seismometer (OBS) data to probe the lower crustal structures. Accompanying the MCS experiments with active sources, 39 OBS stations were deployed along 2 NW-SE trending profiles in the northern SCS. The eastern profile is located southeast of Dongsha atoll, while the western profile extends from the Zhu II depression to the NW sub-basin of SCS. For construction crustal velocity models, we extract shallow velocity structure from the MCS profile data, then we conduct travel-time tomographic inversion on OBS data to derive 2D velocity models. Finally, forward modeling using RAYINVR is subsequently applied to refine the velocity models. Both MCS profiles show that the basement has been offset by normal faults and thick sediments are deposited in the grabens. Many volcanic bodies are observed in the eastern profile, but few appear in the western profile. The OBS velocity model of the eastern profile reveals that the crustal thickness decreases gradually toward the oceanic basin. However the continental crust thins abruptly from continental slope toward the NW sub-basin. A high velocity layer (>7km/s) in the lower crust can be identified in the eastern profile, but not in the western profile. This high velocity layer has been interpreted to be underplating material, however, another possibility is that it might be serpentinized upper mantle, which frequently found in necking zones and COTs zones.

  3. Development of a Multi-Channel Dielectric Resonator Oscillator for Space Communication Applications

    NASA Astrophysics Data System (ADS)

    Dennis, M. S.; Mysoor, N. R.; Cook, B. M.

    2005-08-01

    A novel multi-channel dielectric resonator oscillator (DRO) for Advanced Transponder use is developed for deep-space communication applications. The Advanced Transponder receives a 7.2-GHz (X-band) uplink signal and generates an 8.4-GHz (X-band) coherent or non-coherent downlink signal. The Advanced Transponder architecture incorporates two miniature DROs. These DROs are used in receiver and exciter frequency synthesis phase-locked loops (PLLs) in the Advanced Transponder. The DRO is capable of tuning over 27 Deep Space Network (DSN) X-band uplink channels (30 MHz). The DROs are designed with custom monolithic microwave integrated-circuit (MMIC) negative-resistance voltage-controlled oscillator chips. The receiver DRO design demonstrated a free-running single-sideband phase noise of -107 dBc/Hz at 100 kHz off the carrier frequency, a tuning linearity of +/- 3 percent over the channel locking range, and output power of +10 dBm +/-1 dB. Advantages of the multi-channel DRO include in-flight selection of transponder channel frequency, the enabling of novel mission operations techniques, frequency agility, and a single transponder design that will serve many missions and simplify hardware sparing strategies.

  4. Robust detection of multiple sclerosis lesions from intensity-normalized multi-channel MRI

    NASA Astrophysics Data System (ADS)

    Karpate, Yogesh; Commowick, Olivier; Barillot, Christian

    2015-03-01

    Multiple sclerosis (MS) is a disease with heterogeneous evolution among the patients. Quantitative analysis of longitudinal Magnetic Resonance Images (MRI) provides a spatial analysis of the brain tissues which may lead to the discovery of biomarkers of disease evolution. Better understanding of the disease will lead to a better discovery of pathogenic mechanisms, allowing for patient-adapted therapeutic strategies. To characterize MS lesions, we propose a novel paradigm to detect white matter lesions based on a statistical framework. It aims at studying the benefits of using multi-channel MRI to detect statistically significant differences between each individual MS patient and a database of control subjects. This framework consists in two components. First, intensity standardization is conducted to minimize the inter-subject intensity difference arising from variability of the acquisition process and different scanners. The intensity normalization maps parameters obtained using a robust Gaussian Mixture Model (GMM) estimation not affected by the presence of MS lesions. The second part studies the comparison of multi-channel MRI of MS patients with respect to an atlas built from the control subjects, thereby allowing us to look for differences in normal appearing white matter, in and around the lesions of each patient. Experimental results demonstrate that our technique accurately detects significant differences in lesions consequently improving the results of MS lesion detection.

  5. Multi-Channel neurodegenerative pattern analysis and its application in Alzheimer's disease characterization

    PubMed Central

    Liu, Sidong; Cai, Weidong; Wen, Lingfeng; Feng, David Dagan; Pujol, Sonia; Kikinis, Ron; Fulham, Michael J.; Eberl, Stefan; ADNI

    2014-01-01

    Neuroimaging has played an important role in non-invasive diagnosis and differentiation of neurodegenerative disorders, such as Alzheimer's disease and Mild Cognitive Impairment. Various features have been extracted from the neuroimaging data to characterize the disorders, and these features can be roughly divided into global and local features. Recent studies show a tendency of using local features in disease characterization, since they are capable of identifying the subtle disease-specific patterns associated with the effects of the disease on human brain. However, problems arise if the neuroimaging database involved multiple disorders or progressive disorders, as disorders of different types or at different progressive stages might exhibit different degenerative patterns. It is difficult for the researchers to reach consensus on what brain regions could effectively distinguish multiple disorders or multiple progression stages. In this study we proposed a Multi-Channel pattern analysis approach to identify the most discriminative local brain metabolism features for neurodegenerative disorder characterization. We compared our method to global methods and other pattern analysis methods based on clinical expertise or statistics tests. The preliminary results suggested that the proposed Multi-Channel pattern analysis method outperformed other approaches in Alzheimer's disease characterization, and meanwhile provided important insights into the underlying pathology of Alzheimer's disease and Mild Cognitive Impairment. PMID:24933011

  6. Multi-channel NIRS of the primary motor cortex to discriminate hand from foot activity

    NASA Astrophysics Data System (ADS)

    Koenraadt, K. L. M.; Duysens, J.; Smeenk, M.; Keijsers, N. L. W.

    2012-08-01

    The poor spatial resolution of near-infrared spectroscopy (NIRS) makes it difficult to distinguish two closely located cortical areas from each other. Here, a combination of multi-channel NIRS and a centre of gravity (CoG) approach (widely accepted in the field of transcranial magnetic stimulation; TMS) was used to discriminate between closely located cortical areas activated during hand and foot movements. Similarly, the possibility of separating the more anteriorly represented discrete movements from rhythmic movements was studied. Thirteen healthy right-handed subjects performed rhythmic or discrete (‘task’) hand or foot (‘extremity’) tapping. Hemodynamic responses were measured using an 8-channel NIRS setup. For oxyhemoglobin (OHb) and deoxyhemoglobin (HHb), a CoG was determined for each condition using the mean hemodynamic responses and the coordinates of the channels. Significant hemodynamic responses were found for hand and foot movements. Based on the HHb responses, the NIRS-CoG of hand movements was located 0.6 cm more laterally compared to the NIRS-CoG of foot movements. For OHb responses no difference in NIRS-CoG was found for ‘extremity’ nor for ‘task’. This is the first NIRS study showing hemodynamic responses for isolated foot movements. Furthermore, HHb responses have the potential to be used in multi-channel NIRS experiments requiring differential activation of motor cortex areas linked to either hand or foot movements.

  7. Application of a multi-channel system for continuous monitoring and an early warning system.

    PubMed

    Lee, J H; Song, C H; Kim, B C; Gu, M B

    2006-01-01

    A multi-channel continuous toxicity monitoring system developed in our laboratory, based on two-stage mini-bioreactors, was successfully implemented in the form of computer-based data acquisition. The multi-channel system consists of a series of a two-stage minibioreactor systems connected by a fiber optic probe to a luminometer, and uses genetically engineered bioluminescent bacteria for the detection of the potential toxicity from the soluble chemicals. This system can be stably and continuously operated due to the separation of the culture reactor from the test reactor and accomplish easy and long-term monitoring without system shut down by abrupt inflows of severe polluting chemicals. Four different recombinant bioluminescent bacteria were used in different channels so that the modes of the samples toxicities can be reasonably identified and evaluated based upon the response signature of each channel. The bioluminescent signatures were delivered from four channels by switching one at once, while the data is automatically logged to an IBM compatible computer. We also achieved the enhancement of the system through the manipulation of the dilution rate and the use of thermo-lux fusion strains. Finally, this system is now being implemented to a drinking water reservoir and river for remote sensing as an early warning system. PMID:16722085

  8. Using multi-channel level sets to measure the cytoplasmic localization of HCMV pUL97 in GFP-B-gal fusion constructs.

    PubMed

    Held, Christian; Webel, Rike; Palmisano, Ralf; Hutterer, Corina; Marschall, Manfred; Wittenberg, Thomas

    2014-04-01

    Human cytomegalovirus UL97-encoded protein kinase (pUL97) phosphorylates cellular and viral proteins and is critical for viral replication. To quantify the efficiency of nuclear translocation and to elucidate the role of putative nuclear localization signal (NLS) elements, immunofluorescence analysis of different pUL97 expression constructs was performed. Since manual quantitation of respective expression levels lacks objectivity and reproducibility, and is time-consuming as well, a computer-based model is established. This model enables objective quantitation of the degree of cytoplasmic localization λ. To determine the degree of cytoplasmic localization of different pUL97-GFP-β-gal fusion proteins automatically, a multi-channel segmentation of the nucleus and cytoplasm of transfected HeLa cells is performed in DAPI and GFP micrographs. A watershed transform-based segmentation scheme is used for the segmentation of the cell nuclei. Subsequently, the cytoplasm is segmented using a fast marching level set method. Based on the segmentation of cell nuclei and cytoplasm, λ can be determined for each HeLa cell by quantitation of the ratio of average signal intensity outside and inside the nucleus. The degree of cytoplasmic localization of an individual construct is then determined by evaluating the average and standard deviation of λ for the corresponding HeLa cells. Evaluation demonstrates that nuclear transport of pUL97 is a multilayered mechanism resulting in different efficiencies of nuclear translocation between a small and a large isoform and objective quantitation of the cytoplasmic localization is possible with a high accuracy (96.7% and 94.3%). PMID:24445057

  9. Linear and nonlinear analyses of multi-channel mechanomyographic recordings reveal heterogeneous activation of wrist extensors in presence of delayed onset muscle soreness.

    PubMed

    Madeleine, Pascal; Hansen, Ernst A; Samani, Afshin

    2014-12-01

    In this study, we applied multi-channel mechanomyographic (MMG) recordings in combination with linear and nonlinear analyses to investigate muscular and musculotendinous effects of high intensity eccentric exercise. Twelve accelerometers arranged in a 3 × 4 matrix over the dominant elbow muscles were used to detect MMG activity in 12 healthy participants. Delayed onset muscle soreness was induced by repetitive high intensity eccentric contractions of the wrist extensor muscles. Average rectified values (ARV) as well as percentage of recurrence (%REC) and percentage of determinism (%DET) extracted from recurrence quantification analysis were computed from data obtained during static-dynamic contractions performed before exercise, immediately after exercise, and in presence of muscle soreness. A linear mixed model was used for the statistical analysis. The ARV, %REC, and %DET maps revealed heterogeneous MMG activity over the wrist extensor muscles before, immediately after, and in presence of muscle soreness (P<0.01). The ARVs were higher while the %REC and %DET were lower in presence of muscle soreness compared with before exercise (P<0.05). The study provides new key information on linear and nonlinear analyses of multi-channel MMG recordings of the wrist extensor muscles following eccentric exercise that results in muscle soreness. Recurrence quantification analysis can be suggested as a tool for detection of MMG changes in presence of muscle soreness. PMID:25277830

  10. Calculation of BER in multi-channel silicon optical interconnects: comparative analysis of strip and photonic crystal waveguides

    NASA Astrophysics Data System (ADS)

    You, Jie; Lavdas, Spyros; Panoiu, Nicolae C.

    2016-05-01

    We present an effective approach to evaluate the performance of multi-channel silicon (Si) photonic systems. The system is composed of strip Si photonic waveguides (Si-PhWs) with uniform cross-section or photonic-crystal (PhC) Si waveguides (Si-PhCWs), combined with a set of direct-detection receivers. Moreover, the optical field in each channel is the superposition of a continuous-wave nonreturn-to-zero ON-OFF keying modulated signal and a white Gaussian noise. In order to characterize the optical signal propagation in the waveguides, an accurate mathematical model describing all relevant linear and nonlinear optical effects and its linearized version is employed. In addition, two semi-analytical methods, time- and frequency-domain Karhunen-Loève series expansion, are used to assess the system bit-error-rate (BER). Our analysis reveals that Si-PhCWs provide similar performance as Si-PhWs, but for 100× shorter length. Importantly, much worse BER is achieved in Si-PhCWs when one operates in slow-light regime, due to the enhanced linear and nonlinear effects.

  11. A Multi-Channel Opto-Electronic Sensor to Accurately Monitor Heart Rate against Motion Artefact during Exercise

    PubMed Central

    Alzahrani, Abdullah; Hu, Sijung; Azorin-Peris, Vicente; Barrett, Laura; Esliger, Dale; Hayes, Matthew; Akbare, Shafique; Achart, Jérôme; Kuoch, Sylvain

    2015-01-01

    This study presents the use of a multi-channel opto-electronic sensor (OEPS) to effectively monitor critical physiological parameters whilst preventing motion artefact as increasingly demanded by personal healthcare. The aim of this work was to study how to capture the heart rate (HR) efficiently through a well-constructed OEPS and a 3-axis accelerometer with wireless communication. A protocol was designed to incorporate sitting, standing, walking, running and cycling. The datasets collected from these activities were processed to elaborate sport physiological effects. t-test, Bland-Altman Agreement (BAA), and correlation to evaluate the performance of the OEPS were used against Polar and Mio-Alpha HR monitors. No differences in the HR were found between OEPS, and either Polar or Mio-Alpha (both p > 0.05); a strong correlation was found between Polar and OEPS (r: 0.96, p < 0.001); the bias of BAA 0.85 bpm, the standard deviation (SD) 9.20 bpm, and the limits of agreement (LOA) from −17.18 bpm to +18.88 bpm. For the Mio-Alpha and OEPS, a strong correlation was found (r: 0.96, p < 0.001); the bias of BAA 1.63 bpm, SD 8.62 bpm, LOA from −15.27 bpm to +18.58 bpm. These results demonstrate the OEPS to be capable of carrying out real time and remote monitoring of heart rate. PMID:26473860

  12. Do you see what I hear: experiments in multi-channel sound and 3D visualization for network monitoring?

    NASA Astrophysics Data System (ADS)

    Ballora, Mark; Hall, David L.

    2010-04-01

    Detection of intrusions is a continuing problem in network security. Due to the large volumes of data recorded in Web server logs, analysis is typically forensic, taking place only after a problem has occurred. This paper describes a novel method of representing Web log information through multi-channel sound, while simultaneously visualizing network activity using a 3-D immersive environment. We are exploring the detection of intrusion signatures and patterns, utilizing human aural and visual pattern recognition ability to detect intrusions as they occur. IP addresses and return codes are mapped to an informative and unobtrusive listening environment to act as a situational sound track of Web traffic. Web log data is parsed and formatted using Python, then read as a data array by the synthesis language SuperCollider [1], which renders it as a sonification. This can be done either for the study of pre-existing data sets or in monitoring Web traffic in real time. Components rendered aurally include IP address, geographical information, and server Return Codes. Users can interact with the data, speeding or slowing the speed of representation (for pre-existing data sets) or "mixing" sound components to optimize intelligibility for tracking suspicious activity.

  13. A multi-channel opto-electronic sensor to accurately monitor heart rate against motion artefact during exercise.

    PubMed

    Alzahrani, Abdullah; Hu, Sijung; Azorin-Peris, Vicente; Barrett, Laura; Esliger, Dale; Hayes, Matthew; Akbare, Shafique; Achart, Jérôme; Kuoch, Sylvain

    2015-01-01

    This study presents the use of a multi-channel opto-electronic sensor (OEPS) to effectively monitor critical physiological parameters whilst preventing motion artefact as increasingly demanded by personal healthcare. The aim of this work was to study how to capture the heart rate (HR) efficiently through a well-constructed OEPS and a 3-axis accelerometer with wireless communication. A protocol was designed to incorporate sitting, standing, walking, running and cycling. The datasets collected from these activities were processed to elaborate sport physiological effects. t-test, Bland-Altman Agreement (BAA), and correlation to evaluate the performance of the OEPS were used against Polar and Mio-Alpha HR monitors. No differences in the HR were found between OEPS, and either Polar or Mio-Alpha (both p > 0.05); a strong correlation was found between Polar and OEPS (r: 0.96, p < 0.001); the bias of BAA 0.85 bpm, the standard deviation (SD) 9.20 bpm, and the limits of agreement (LOA) from -17.18 bpm to +18.88 bpm. For the Mio-Alpha and OEPS, a strong correlation was found (r: 0.96, p < 0.001); the bias of BAA 1.63 bpm, SD 8.62 bpm, LOA from -15.27 bpm to +18.58 bpm. These results demonstrate the OEPS to be capable of carrying out real time and remote monitoring of heart rate. PMID:26473860

  14. High resolution time interval meter

    DOEpatents

    Martin, A.D.

    1986-05-09

    Method and apparatus are provided for measuring the time interval between two events to a higher resolution than reliability available from conventional circuits and component. An internal clock pulse is provided at a frequency compatible with conventional component operating frequencies for reliable operation. Lumped constant delay circuits are provided for generating outputs at delay intervals corresponding to the desired high resolution. An initiation START pulse is input to generate first high resolution data. A termination STOP pulse is input to generate second high resolution data. Internal counters count at the low frequency internal clock pulse rate between the START and STOP pulses. The first and second high resolution data are logically combined to directly provide high resolution data to one counter and correct the count in the low resolution counter to obtain a high resolution time interval measurement.

  15. Passive multi-channel analysis of surface waves with cross-correlations and beamforming. Application to a sea dike

    NASA Astrophysics Data System (ADS)

    Le Feuvre, M.; Joubert, A.; Leparoux, D.; Côte, P.

    2015-03-01

    We introduce the use of cross-correlations in the passive multi-channel analysis of surface waves (MASW), and report an improvement in the determination of subsurface shear velocities from ambient seismic noise. Velocities are measured from phase-shifts that are also related to the source location. Consequently, the accuracy with which velocities can be inferred depends on the ability of the array to locate noise sources. The computation of cross-correlations for each receiver pair allows increasing the effective spatial sampling of the array. For this reason, we show that beamforming is more efficient with cross-correlated signals. Consequently, MASW performed with cross-correlations produces a dispersion diagram where aliasing is reduced and signal-to-noise ratio increased. The proposed method is validated with synthetic records. It is then applied on passive recordings obtained on top of a sea dike at high tide, where sea waves were acting as continuous seismic sources. Surface wave velocities that favorably compare with hammer shot measurements are inferred.

  16. Implementation of the multi-channel monolith reactor in an optimisation procedure for heterogeneous oxidation catalysts based on genetic algorithms.

    PubMed

    Breuer, Christian; Lucas, Martin; Schütze, Frank-Walter; Claus, Peter

    2007-01-01

    A multi-criteria optimisation procedure based on genetic algorithms is carried out in search of advanced heterogeneous catalysts for total oxidation. Simple but flexible software routines have been created to be applied within a search space of more then 150,000 individuals. The general catalyst design includes mono-, bi- and trimetallic compositions assembled out of 49 different metals and depleted on an Al2O3 support in up to nine amount levels. As an efficient tool for high-throughput screening and perfectly matched to the requirements of heterogeneous gas phase catalysis - especially for applications technically run in honeycomb structures - the multi-channel monolith reactor is implemented to evaluate the catalyst performances. Out of a multi-component feed-gas, the conversion rates of carbon monoxide (CO) and a model hydrocarbon (HC) are monitored in parallel. In combination with further restrictions to preparation and pre-treatment a primary screening can be conducted, promising to provide results close to technically applied catalysts. Presented are the resulting performances of the optimisation process for the first catalyst generations and the prospect of its auto-adaptation to specified optimisation goals. PMID:17266517

  17. An online multi-channel SSVEP-based brain-computer interface using a canonical correlation analysis method

    NASA Astrophysics Data System (ADS)

    Bin, Guangyu; Gao, Xiaorong; Yan, Zheng; Hong, Bo; Gao, Shangkai

    2009-08-01

    In recent years, there has been increasing interest in using steady-state visual evoked potential (SSVEP) in brain-computer interface (BCI) systems. However, several aspects of current SSVEP-based BCI systems need improvement, specifically in relation to speed, user variation and ease of use. With these improvements in mind, this paper presents an online multi-channel SSVEP-based BCI system using a canonical correlation analysis (CCA) method for extraction of frequency information associated with the SSVEP. The key parameters, channel location, window length and the number of harmonics, are investigated using offline data, and the result used to guide the design of the online system. An SSVEP-based BCI system with six targets, which use nine channel locations in the occipital and parietal lobes, a window length of 2 s and the first harmonic, is used for online testing on 12 subjects. The results show that the proposed BCI system has a high performance, achieving an average accuracy of 95.3% and an information transfer rate of 58 ± 9.6 bit min-1. The positive characteristics of the proposed system are that channel selection and parameter optimization are not required, the possible use of harmonic frequencies, low user variation and easy setup.

  18. BioSigPlot: an opensource tool for the visualization of multi-channel biomedical signals with Matlab.

    PubMed

    Boudet, Samuel; Peyrodie, Laurent; Gallois, Philippe; de l'Aulnoit, Denis Houzé; Cao, Hua; Forzy, Gérard

    2013-01-01

    This paper presents a Matlab-based software (MathWorks inc.) called BioSigPlot for the visualization of multi-channel biomedical signals, particularly for the EEG. This tool is designed for researchers on both engineering and medicine who have to collaborate to visualize and analyze signals. It aims to provide a highly customizable interface for signal processing experimentation in order to plot several kinds of signals while integrating the common tools for physician. The main advantages compared to other existing programs are the multi-dataset displaying, the synchronization with video and the online processing. On top of that, this program uses object oriented programming, so that the interface can be controlled by both graphic controls and command lines. It can be used as EEGlab plug-in but, since it is not limited to EEG, it would be distributed separately. BioSigPlot is distributed free of charge (http://biosigplot.sourceforge.net), under the terms of GNU Public License for non-commercial use and open source development. PMID:24110098

  19. Turbulent mixing of plasma and electrolyte in the multi-channel discharge between a droplet and electrolyte

    NASA Astrophysics Data System (ADS)

    Kayumov, R. R.; Gaysin, Al F.; Son, E. E.; Gaysin, Az F.; Gaysin, F. M.

    2010-12-01

    The multi-channel discharge between an electrolyte cathode and an electrolyte anode is of significant scientific and practical importance. The physical properties and characteristics of these types of discharges at atmospheric pressure have not yet been studied. This paper is devoted to the study of the multi-channel discharge between an electrolyte droplet cathode and an electrolyte cell anode. The experiments were carried out in the current range of 0.01-1.5 A and the voltage range of 50-1300 V. The flow rate of the droplet forming electrolyte was 0.2 g s-1. A NaCl solution was used as electrolyte.

  20. All-optical multi-channel wavelength conversion of Nyquist 16 QAM signal using a silicon waveguide.

    PubMed

    Long, Yun; Liu, Jun; Hu, Xiao; Wang, Andong; Zhou, Linjie; Zou, Kaiheng; Zhu, Yixiao; Zhang, Fan; Wang, Jian

    2015-12-01

    We experimentally demonstrate on-chip all-optical multi-channel wavelength conversion of Nyquist 16 ary quadrature amplitude modulation (16 QAM) signal in a silicon waveguide. The measured optical signal-to-noise ratio (OSNR) penalties of wavelength conversion are ∼2  dB. The observed constellations of converted idlers indicate favorable performance of silicon-waveguide-based multi-channel wavelength conversion. We also experimentally study and compare the phase-conjugated wavelength conversion by degenerate four-wave mixing (FWM) and transparent wavelength conversion by non-degenerate FWM in the silicon waveguide. PMID:26625029

  1. Telephone speech enhancement for hearing-impaired listeners using multi-channel compression

    NASA Astrophysics Data System (ADS)

    Natarajan, Harikrishna P.; Krishnamurthy, Ashok K.; Feth, Lawrence L.

    2002-05-01

    Elderly listeners with sensorineural hearing impairment usually have difficulty with telephone communication if they do not use a hearing aid or telephone amplifier. In many cases, these devices may not be readily available or maybe uncomfortable to use. We describe here an alternative strategy to enhance the speech by pre-processing the signal before sending it over the telephone line. The pre-processing is based on a multi-channel compression algorithm that modifies the critical band spectrum of the speech signal to bring it within the dynamic hearing range of the listener, while also compensating for the effects of the telephone line. We describe the algorithm and the results of a simulation study in which the Articulation Index (AI) is used to measure the intelligibility enhancement, and the Glasberg, Moore and Stone (1999) model is used to simulate the effects of the hearing loss.

  2. Scalable screen-size enlargement by multi-channel viewing-zone scanning holography.

    PubMed

    Takaki, Yasuhiro; Nakaoka, Mitsuki

    2016-08-01

    Viewing-zone scanning holographic displays can enlarge both the screen size and the viewing zone. However, limitations exist in the screen size enlargement process even if the viewing zone is effectively enlarged. This study proposes a multi-channel viewing-zone scanning holographic display comprising multiple projection systems and a planar scanner to enable the scalable enlargement of the screen size. Each projection system produces an enlarged image of the screen of a MEMS spatial light modulator. The multiple enlarged images produced by the multiple projection systems are seamlessly tiled on the planar scanner. This screen size enlargement process reduces the viewing zones of the projection systems, which are horizontally scanned by the planar scanner comprising a rotating off-axis lens and a vertical diffuser to enlarge the viewing zone. A screen size of 7.4 in. and a viewing-zone angle of 43.0° are demonstrated. PMID:27505840

  3. A method of multi-channel reference signals acquiring in broadband ANC

    NASA Astrophysics Data System (ADS)

    Ma, Ling-Kun; Huang, Jian-Guo; Zhang, Li-Jie

    2008-09-01

    In a flank array on an unmanned underwater vehicle (UUV), self-generated noise which has broadband and colored spectrum property in frequency and spatial domain is the main factor affecting the performance of weak signal detection, so the technique of adaptive noise cancellation (ANC) as well as physical denoising and active noise cancellation are often used in practice. Because ANC is based on correlations, improvements in performance come from better correlation between reference signals and primary signals. Taking full advantage of the characteristics of flank arrays and the characteristics of information obtained from hydrophones, a new method for reference signal acquisition for adaptive noise cancellation is proposed, in which the multi-channel reference signals are obtained by accurate delaying for a given direction of arrival (DOA) and differencing between adjacent outputs of array elements. The validity of the proposed method was verified through system modeling simulations and lake experiments which showed good performance with little additional computational burden.

  4. Non-locally regularized segmentation of multiple sclerosis lesion from multi-channel MRI data

    PubMed Central

    Gao, Jingjing; Li, Chunming; Feng, Chaolu; Xie, Mei; Yin, Yilong; Davatzikos, Christos

    2015-01-01

    Segmentation of multiple sclerosis (MS) lesion is important for many neuroimaging studies. In this paper, we propose a novel algorithm for automatic segmentation of MS lesions from multi-channel MR images (T1W, T2W and FLAIR images). The proposed method is an extension of Li et al.'s algorithm in [1], which only segments the normal tissues from T1W images. The proposed method is aimed to segment MS lesions, while normal tissues are also segmented and bias field is estimated to handle intensity inhomogeneities in the images. Another contribution of this paper is the introduction of a nonlocal means technique to achieve spatially regularized segmentation, which overcomes the influence of noise. Experimental results have demonstrated the effectiveness and advantages of the proposed algorithm. PMID:24948583

  5. MS lesion segmentation using a multi-channel patch-based approach with spatial consistency

    NASA Astrophysics Data System (ADS)

    Mechrez, Roey; Goldberger, Jacob; Greenspan, Hayit

    2015-03-01

    This paper presents an automatic method for segmentation of Multiple Sclerosis (MS) in Magnetic Resonance Images (MRI) of the brain. The approach is based on similarities between multi-channel patches (T1, T2 and FLAIR). An MS lesion patch database is built using training images for which the label maps are known. For each patch in the testing image, k similar patches are retrieved from the database. The matching labels for these k patches are then combined to produce an initial segmentation map for the test case. Finally a novel iterative patch-based label refinement process based on the initial segmentation map is performed to ensure spatial consistency of the detected lesions. A leave-one-out evaluation is done for each testing image in the MS lesion segmentation challenge of MICCAI 2008. Results are shown to compete with the state-of-the-art methods on the MICCAI 2008 challenge.

  6. Design of a multi-channel free space optical interconnection component

    NASA Astrophysics Data System (ADS)

    Jia, Da-Gong; Zhang, Pei-Song; Jing, Wen-Cai; Tan, Jun; Zhang, Hong-Xia; Zhang, Yi-Mo

    2008-11-01

    A multi-channel free space optical interconnection component, fiber optic rotary joint, was designed using a Dove prism. When the Dove prism is rotated an angle of α around the longitudinal axis, the image rotates an angle of 2 α. The optical interconnection component consists of the signal transmission system, Dove prim and driving mechanism. The planetary gears are used to achieve the speed ratio of 2:1 between the total optical interconnection component and the Dove prism. The C-lenses are employed to couple different optical signals in the signal transmission system. The coupling loss between the receiving fiber of stationary part and the transmitting fiber of rotary part is measured.

  7. Multi-channel multi-carrier generation using multi-wavelength frequency shifting recirculating loop.

    PubMed

    Li, Xinying; Yu, Jianjun; Dong, Ze; Zhang, Junwen; Shao, Yufeng; Chi, Nan

    2012-09-24

    We propose and experimentally demonstrate a novel scheme to generate optical frequency-locked multi-channel multi-carriers (MCMC), using a recirculating frequency shifter (RFS) loop based on multi-wavelength frequency shifting single side band (MWFS-SSB) modulation. In this scheme, optical subcarriers with multiple wavelengths can be generated each round. Furthermore, the generated MCMC are frequency- and phase-locked within each channel, and therefore can be effectively used for WDM superchannel. Dual-wavelength frequency shifting SSB modulation is carried out with dual-wavelength optical seed source in our experimental demonstration. Using this scheme, we successfully generate dual-channel multi-carriers, and one channel has 28 subcarriers while the other has 29 ones with 25-GHz subcarrier spacing. We also experimentally demonstrate that this kind of source can be used to carry 50-Gb/s optical polarization-division-multiplexing quadrature phase shift keying (PDM-QPSK) signal. PMID:23037333

  8. Signal Detection of Multi-Channel Capillary Electrophoresis Chip Based on CCD

    NASA Astrophysics Data System (ADS)

    Lv, Hongfeng; Yan, Weiping; Yang, Xiaobo; Li, Jiechao; Zhu, Jieying

    2012-12-01

    A kind of multi-channel capillary electrophoresis (CE) chip signal detection system based on CCD was developed. The output signal of the CCD sensor was processed by a series of pre-processing circuits and ADC, and then it was collected by the Field Programmable Gate Array (FPGA) chip which communicated with a host computer. The core in FPGA was designed to control the signal flow of the CCD and transfer the data to PC based on a Nios II embedded soft-processor. The application of PC was used to store the data and demonstrate the curve. The measurement of the fluorescent signals for different concentration Rhodamine B dyes is presented and the comparison with other detection systems is also discussed.

  9. Multi-channel optical sensor-array for measuring ballistocardiograms and respiratory activity in bed.

    PubMed

    Brüser, Christoph; Kerekes, Anna; Winter, Stefan; Leonhardt, Steffen

    2012-01-01

    Our work covers improvements in sensors and signal processing for unobtrusive, long-term monitoring of cardiac (and respiratory) rhythms using only non-invasive vibration sensors. We describe a system for the unobtrusive monitoring of vital signs by means of an array of novel optical ballistocardiography (BCG) sensors placed underneath a regular bed mattress. Furthermore, we analyze the systems spatial sensitivity and present proof-of-concept results comparing our system to a more conventional BCG system based on a single electromechanical-film (EMFi) sensor. Our preliminary results suggest that the proposed optical multi-channel system could have the potential to reduce beat-to-beat heart rate estimation errors, as well as enable the analysis of more complex breathing patterns. PMID:23367061

  10. Scale-Free Brain Quartet: Artistic Filtering of Multi-Channel Brainwave Music

    PubMed Central

    Wu, Dan; Li, Chaoyi; Yao, Dezhong

    2013-01-01

    To listen to the brain activities as a piece of music, we proposed the scale-free brainwave music (SFBM) technology, which translated scalp EEGs into music notes according to the power law of both EEG and music. In the present study, the methodology was extended for deriving a quartet from multi-channel EEGs with artistic beat and tonality filtering. EEG data from multiple electrodes were first translated into MIDI sequences by SFBM, respectively. Then, these sequences were processed by a beat filter which adjusted the duration of notes in terms of the characteristic frequency. And the sequences were further filtered from atonal to tonal according to a key defined by the analysis of the original music pieces. Resting EEGs with eyes closed and open of 40 subjects were utilized for music generation. The results revealed that the scale-free exponents of the music before and after filtering were different: the filtered music showed larger variety between the eyes-closed (EC) and eyes-open (EO) conditions, and the pitch scale exponents of the filtered music were closer to 1 and thus it was more approximate to the classical music. Furthermore, the tempo of the filtered music with eyes closed was significantly slower than that with eyes open. With the original materials obtained from multi-channel EEGs, and a little creative filtering following the composition process of a potential artist, the resulted brainwave quartet opened a new window to look into the brain in an audible musical way. In fact, as the artistic beat and tonal filters were derived from the brainwaves, the filtered music maintained the essential properties of the brain activities in a more musical style. It might harmonically distinguish the different states of the brain activities, and therefore it provided a method to analyze EEGs from a relaxed audio perspective. PMID:23717527