Sample records for narrow bony cochlear

  1. Value of intracochlear electrically evoked auditory brainstem response after cochlear implantation in patients with narrow internal auditory canal.

    PubMed

    Song, Mee Hyun; Bae, Mi Ran; Kim, Hee Nam; Lee, Won-Sang; Yang, Won Sun; Choi, Jae Young

    2010-08-01

    Cochlear implantation in patients with narrow internal auditory canal (IAC) can result in variable outcomes; however, preoperative evaluations have limitations in accurately predicting outcomes. In this study, we analyzed the outcomes of cochlear implantation in patients with narrow IAC and correlated the intracochlear electrically evoked auditory brainstem response (EABR) findings to postoperative performance to determine the prognostic significance of intracochlear EABR. Retrospective case series at a tertiary hospital. Thirteen profoundly deaf patients with narrow IAC who received cochlear implantation from 2002 to 2008 were included in this study. Postoperative performance was evaluated after at least 12 months of follow-up, and postoperative intracochlear EABR was measured to determine its correlation with outcome. The clinical significance of electrically evoked compound action potential (ECAP) was also analyzed. Patients with narrow IAC showed postoperative auditory performances ranging from CAP 0 to 4 after cochlear implantation. Intracochlear EABR measured postoperatively demonstrated prognostic value in the prediction of long-term outcomes, whereas ECAP measurements failed to show a significant correlation with outcome. Consistent with the advantages of intracochlear EABR over extracochlear EABR, this study demonstrates that intracochlear EABR has prognostic significance in predicting long-term outcomes in patients with narrow IAC. Intracochlear EABR measured either intraoperatively or in the early postoperative period may play an important role in deciding whether to continue with auditory rehabilitation using a cochlear implant or to switch to an auditory brainstem implant so as not to miss the optimal timing for language development.

  2. Characteristics and pathogenesis of facial nerve stimulation after cochlear implant surgeries: A single-center retrospective analysis from 1,151 patients.

    PubMed

    Kim, Y R; Yoo, M H; Lee, J Y; Yang, C J; Park, J W; Kang, B C; Kang, W S; Ahn, J H; Chung, J W; Park, H J

    2018-05-29

    Incidence of facial nerve stimulation (FNS) was 2.8% (32 out of 1151) and higher in ears with cochlear anomaly (6.4%, 25 out of 391) than without cochlear anomaly (0.9%, 7 out of 760). FNS occurred at various current levels and locations of electrodes by different mechanisms related to incomplete insertion of electrodes, cochleo-facial dehiscence, and types of cochlear anomalies. FNS at apical electrodes related to cochleo-facial dehiscence with low current levels, and FNS at basal electrodes with high current levels and partial insertion of electrodes. FNS at most electrodes with high current levels was the most common type in patients with a common cavity or narrowing of the bony cochlear nerve canal. Understanding the mechanisms of FNS might provide insight for preventing FNS when performing CI surgeries. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  3. A new computed tomography method to identify meningitis-related cochlear ossification and fibrosis before cochlear implantation.

    PubMed

    Ichikawa, Kazunori; Kashio, Akinori; Mori, Harushi; Ochi, Atushi; Karino, Shotaro; Sakamoto, Takashi; Kakigi, Akinobu; Yamasoba, Tatsuya

    2014-04-01

    To develop a new method to determine the presence of intracochlear ossification and/or fibrosis in cochlear implantation candidates with bilateral profound deafness following meningitis. Diagnostic test assessment. A university hospital. This study involved 15 ears from 13 patients with profound deafness following meningitis who underwent cochlear implantation. These ears showed normal structures, soft tissue, partial bony occlusion, and complete bony occlusion in 4, 3, 2, and 6 ears, respectively. We measured radiodensity in Hounsfield units (HU) using 0.5-mm-thick axial high-resolution computed tomography image slices at 3 different levels in the basal turn, the fenestration, and inferior and ascending segment sites, located along the electrode-insertion path. Pixel-level analysis on the DICOM viewer yielded actual computed tomography values of intracochlear soft tissues by eliminating the partial volume effect. The values were compared with the intraoperative findings. Values for ossification (n = 12) ranged from +547 HU to +1137 HU; for fibrosis (n = 11), from +154 HU to +574 HU; and for fluid (n = 22), from -49 HU to +255 HU. From these values, we developed 2 presets of window width (WW) and window level (WL): (1) WW: 1800, WL: 1100 (200 HU to 2000 HU) and (2) WW: 1500, WL: 1250 (500 HU to 2000 HU). The results using these 2 presets corresponded well to the intraoperative findings. Our new method is easy and feasible for preoperative determination of the presence of cochlear ossification and/or fibrosis that develops following meningitis.

  4. Microanatomy of the cochlear hook

    NASA Astrophysics Data System (ADS)

    Kwan, Changyow Claire; Tan, Xiaodong; Stock, Stuart R.; Soriano, Carmen; Xiao, Xianghui; Richter, Claus-Peter

    2017-09-01

    Communication among humans occurs through coding and decoding of acoustic information. The inner ear or cochlea acts as a frequency analyzer and divides the acoustic signal into small frequency bands, which are processed at different sites along the cochlea. The mechano-electrical conversion is accomplished by the soft tissue structures in the cochlea. While the anatomy for most of the cochlea has been well described, a detailed description of the very high frequency and vulnerable cochlear hook region is missing. To study the cochlear hook, mice cochleae were imaged with synchrotron radiation and high-resolution reconstructions have been made from the tomographic scans. This is the first detailed description of the bony and soft tissues of the hook region of the mammalian cochlea.

  5. Comparative Anatomy of the Bony Labyrinth (Inner Ear) of Placental Mammals

    PubMed Central

    Ekdale, Eric G.

    2013-01-01

    Background Variation is a naturally occurring phenomenon that is observable at all levels of morphology, from anatomical variations of DNA molecules to gross variations between whole organisms. The structure of the otic region is no exception. The present paper documents the broad morphological diversity exhibited by the inner ear region of placental mammals using digital endocasts constructed from high-resolution X-ray computed tomography (CT). Descriptions cover the major placental clades, and linear, angular, and volumetric dimensions are reported. Principal Findings The size of the labyrinth is correlated to the overall body mass of individuals, such that large bodied mammals have absolutely larger labyrinths. The ratio between the average arc radius of curvature of the three semicircular canals and body mass of aquatic species is substantially lower than the ratios of related terrestrial taxa, and the volume percentage of the vestibular apparatus of aquatic mammals tends to be less than that calculated for terrestrial species. Aspects of the bony labyrinth are phylogenetically informative, including vestibular reduction in Cetacea, a tall cochlear spiral in caviomorph rodents, a low position of the plane of the lateral semicircular canal compared to the posterior canal in Cetacea and Carnivora, and a low cochlear aspect ratio in Primatomorpha. Significance The morphological descriptions that are presented add a broad baseline of anatomy of the inner ear across many placental mammal clades, for many of which the structure of the bony labyrinth is largely unknown. The data included here complement the growing body of literature on the physiological and phylogenetic significance of bony labyrinth structures in mammals, and they serve as a source of data for future studies on the evolution and function of the vertebrate ear. PMID:23805251

  6. The Crista Fenestra and Its Impact on the Surgical Approach to the Scala Tympani during Cochlear Implantation.

    PubMed

    Angeli, Roberto D; Lavinsky, Joel; Setogutti, Enio T; Lavinsky, Luiz

    2017-01-01

    The aim of this work was to describe the dimensions of the crista fenestra and determine its presence by means of high-resolution computed tomography (CT) for the purpose of cochlear implantation via the round window approach. A series of 10 adult human temporal bones underwent high-resolution CT scanning and were further dissected for microscopic study of the round window niche. In all of the specimens, the round window membrane was fully visualized after the complete removal of bony overhangs. The crista fenestra was identified as a sharp bony crest located in the anterior and inferior borders of the niche; its area ranged from 0.28 to 0.80 mm2 (mean 0.51 ± 0.18). The proportion of the area occupied by the crista fenestra in the whole circumference of the round window ranged from 23 to 50% (mean 36%). We found a moderate positive correlation between the area of the niche and the dimensions of the crista fenestra (Spearman rho: 0.491). In every case, high-resolution CT scanning was unable to determine the presence of the crista fenestra. The crista fenestra occupies a variable but expressive area within the bony round window niche. Narrower round window niches tended to house smaller crests. The presence of the crista fenestra is an important obstacle to adequate access to the scala tympani. Nevertheless, a high-resolution CT scan provides no additional preoperative information with regard to its presence for the purpose of surgical access to the scala tympani via the round window niche. © 2017 S. Karger AG, Basel.

  7. Predictors of round window accessibility for adult cochlear implantation based on pre-operative CT scan: a prospective observational study.

    PubMed

    Park, Edward; Amoodi, Hosam; Kuthubutheen, Jafri; Chen, Joseph M; Nedzelski, Julian M; Lin, Vincent Y W

    2015-05-28

    Cochlear implantation has become a mainstream treatment option for patients with severe to profound sensorineural hearing loss. During cochlear implant, there are key surgical steps which are influenced by anatomical variations between each patient. The aim of this study is to determine if there are potential predictors of difficulties that may be encountered during the cortical mastoidectomy, facial recess approach and round window access in cochlear implant surgery based upon pre-operative temporal bone CT scan. Fifty seven patients undergoing unilateral cochlear implantation were analyzed. Difficulty with 1) cortical mastoidectomy, 2) facial recess approach, and 3) round window access were scored intra-operatively by the surgeon in a blinded fashion (1 = "easy", 2 = "moderate", 3 = "difficult"). Pre-operative temporal bone CT scans were analyzed for 1) degree of mastoid aeration; 2) location of the sigmoid sinus; 3) height of the tegmen; 4) the presence of air cells in the facial recess, and 5) degree of round window bony overhang. Poor mastoid aeration and lower tegmen position, but not the location of sigmoid sinus, are associated with greater difficulty with the cortical mastoidectomy. Presence of an air cell around the facial nerve was predictive of easier facial recess access. However, the degree of round window bony overhang was not predictive of difficulty associated with round window access. Certain parameters on the pre-operative temporal bone CT scan may be useful in predicting potential difficulties encountered during the key steps involved in cochlear implant surgery.

  8. Cochlear transducer operating point adaptation.

    PubMed

    Zou, Yuan; Zheng, Jiefu; Ren, Tianying; Nuttall, Alfred

    2006-04-01

    The operating point (OP) of outer hair cell (OHC) mechanotransduction can be defined as any shift away from the center position on the transduction function. It is a dc offset that can be described by percentage of the maximum transduction current or as an equivalent dc pressure in the ear canal. The change of OP can be determined from the changes of the second and third harmonics of the cochlear microphonic (CM) following a calibration of its initial value. We found that the initial OP was dependent on sound level and cochlear sensitivity. From CM generated by a lower sound level at 74 dB SPL to avoid saturation and suppression of basal turn cochlear amplification, the OHC OP was at constant 57% of the maximum transduction current (an ear canal pressure of -0.1 Pa). To perturb the OP, a constant force was applied to the bony shell of the cochlea at the 18 kHz best frequency location using a blunt probe. The force applied over the scala tympani induced an OP change as if the organ of Corti moved toward the scala vestibuli (SV) direction. During an application of the constant force, the second harmonic of the CM partially recovered toward the initial level, which could be described by two time constants. Removing the force induced recovery of the second harmonic to its normal level described by a single time constant. The force applied over the SV caused an opposite result. These data indicate an active mechanism for OHC transduction OP.

  9. Recognition and Comprehension of "Narrow Focus" by Young Adults With Prelingual Hearing Loss Using Hearing Aids or Cochlear Implants.

    PubMed

    Segal, Osnat; Kishon-Rabin, Liat

    2017-12-20

    The stressed word in a sentence (narrow focus [NF]) conveys information about the intent of the speaker and is therefore important for processing spoken language and in social interactions. The ability of participants with severe-to-profound prelingual hearing loss to comprehend NF has rarely been investigated. The purpose of this study was to assess the recognition and comprehension of NF by young adults with prelingual hearing loss compared with those of participants with normal hearing (NH). The participants included young adults with hearing aids (HA; n = 10), cochlear implants (CI; n = 12), and NH (n = 18). The test material included the Hebrew Narrow Focus Test (Segal, Kaplan, Patael, & Kishon-Rabin, in press), with 3 subtests, which was used to assess the recognition and comprehension of NF in different contexts. The following results were obtained: (a) CI and HA users successfully recognized the stressed word, with the worst performance for CI; (b) HA and CI comprehended NF less well than NH; and (c) the comprehension of NF was associated with verbal working memory and expressive vocabulary in CI users. Most CI and HA users were able to recognize the stressed word in a sentence but had considerable difficulty understanding it. Different factors may contribute to this difficulty, including the memory load during the task itself and linguistic and pragmatic abilities. https://doi.org/10.23641/asha.5572792.

  10. Cochlear Implantation After Partial or Subtotal Cochleoectomy for Intracochlear Schwannoma Removal-A Technical Report.

    PubMed

    Plontke, Stefan K; Kösling, Sabrina; Rahne, Torsten

    2018-03-01

    To describe the technique for surgical tumor removal, cochlear implant (CI) electrode placement and reconstruction of the surgical defect in patients with intracochlear schwannomas. Retrospective case review. Tertiary referral center. Ten patients (five men, five women, mean age 48 ± 12 yr) with profound or severe to profound hearing loss due to intralabyrinthine schwannomas with intracochlear location. Surgical tumor removal through extended round window approach, partial or subtotal cochleoectomy with or without labyrinthectomy and reconstruction of the surgical defect with cartilage, perichondrium or temporal muscle fascia, and bone pâté. Eight patients received a cochlear implant in the same procedure. Retrospective evaluation of clinical outcome including safety aspects (adverse events) and audiological performance at early follow up in cases of cochlear implantation. The tumor was successfully removed in all cases without macroscopic (operation microscope and endoscope) tumor remnants in the bony labyrinth apart from one case with initial transmodiolar growth. One patient needed revision surgery for labyrinthine fistula. At short-term follow up (3-month post-surgery), good hearing results with the cochlear implant were obtained in all but one patient with a word recognition score of 100% for numbers, and 64 ± 14% for monosyllables (at 65 dB SPL in quiet). Surgical tumor removal and cochlear implantation is a promising treatment strategy in the management of intralabyrinthine schwannoma with intracochlear location, further extending the indication range for cochlear implantation. It is, however, of importance to observe the long-term outcome in these patients and to address challenges like follow up with magnetic resonance imaging.

  11. A novel speech-processing strategy incorporating tonal information for cochlear implants.

    PubMed

    Lan, N; Nie, K B; Gao, S K; Zeng, F G

    2004-05-01

    Good performance in cochlear implant users depends in large part on the ability of a speech processor to effectively decompose speech signals into multiple channels of narrow-band electrical pulses for stimulation of the auditory nerve. Speech processors that extract only envelopes of the narrow-band signals (e.g., the continuous interleaved sampling (CIS) processor) may not provide sufficient information to encode the tonal cues in languages such as Chinese. To improve the performance in cochlear implant users who speak tonal language, we proposed and developed a novel speech-processing strategy, which extracted both the envelopes of the narrow-band signals and the fundamental frequency (F0) of the speech signal, and used them to modulate both the amplitude and the frequency of the electrical pulses delivered to stimulation electrodes. We developed an algorithm to extract the fundatmental frequency and identified the general patterns of pitch variations of four typical tones in Chinese speech. The effectiveness of the extraction algorithm was verified with an artificial neural network that recognized the tonal patterns from the extracted F0 information. We then compared the novel strategy with the envelope-extraction CIS strategy in human subjects with normal hearing. The novel strategy produced significant improvement in perception of Chinese tones, phrases, and sentences. This novel processor with dynamic modulation of both frequency and amplitude is encouraging for the design of a cochlear implant device for sensorineurally deaf patients who speak tonal languages.

  12. Cochlear implantation using a custom guide catheter in fourteen patients with incomplete partition type III.

    PubMed

    Tian, Hao; Wang, Line; Gao, Fenqi; Liang, Wenqi; Peng, Kevin A

    2018-05-22

    Incomplete partition type III (IP-III), also termed X-linked deafness with stapes gusher, is a heterogeneous condition that predominantly affects males; however, females demonstrating the phenotype also exist. The absence of a bony partition between the fundus of the internal auditory canal (IAC) and cochlea predisposes these patients to cerebrospinal fluid leak or electrode passage into the IAC when performing cochlear implantation. We describe a surgeon-fabricated guide catheter, made intraoperatively from a 16-gauge intravenous catheter, that helps avoid electrode passage into the IAC during CI for patients with IP-III. Acceptable cochlear implant outcomes were attainable in IP-III patients, but these patients scored worse than matched CI patients with normal inner ear structures. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  13. The bony labyrinth of the middle Pleistocene Sima de los Huesos hominins (Sierra de Atapuerca, Spain).

    PubMed

    Quam, Rolf; Lorenzo, Carlos; Martínez, Ignacio; Gracia-Téllez, Ana; Arsuaga, Juan Luis

    2016-01-01

    We performed 3D virtual reconstructions based on CT scans to study the bony labyrinth morphology in 14 individuals from the large middle Pleistocene hominin sample from the site of the Sima de los Huesos (SH) in the Sierra de Atapuerca in northern Spain. The Atapuerca (SH) hominins represent early members of the Neandertal clade and provide an opportunity to compare the data with the later in time Neandertals, as well as Pleistocene and recent humans more broadly. The Atapuerca (SH) hominins do not differ from the Neandertals in any of the variables related to the absolute and relative sizes and shape of the semicircular canals. Indeed, the entire Neandertal clade seems to be characterized by a derived pattern of canal proportions, including a relatively small posterior canal and a relatively large lateral canal. In contrast, one of the most distinctive features observed in Neandertals, the low placement of the posterior canal (i.e., high sagittal labyrinthine index), is generally not present in the Atapuerca (SH) hominins. This low placement is considered a derived feature in Neandertals and is correlated with a more vertical orientation of the ampullar line (LSCm < APA), posterior surface of the petrous pyramid (LSCm > PPp), and third part of the facial canal (LSCm < FC3). Some variation is present within the Atapuerca (SH) sample, however, with a few individuals approaching the Neandertal condition more closely. In addition, the cochlear shape index in the Atapuerca (SH) hominins is low, indicating a reduction in the height of the cochlea. Although the phylogenetic polarity of this feature is less clear, the low shape index in the Atapuerca (SH) hominins may be a derived feature. Regardless, cochlear height subsequently increased in Neandertals. In contrast to previous suggestions, the expanded data in the present study indicate no difference across the genus Homo in the angle of inclination of the cochlear basal turn (COs < LSCm). Principal components

  14. Commissural axons of the mouse cochlear nucleus.

    PubMed

    Brown, M Christian; Drottar, Marie; Benson, Thane E; Darrow, Keith

    2013-05-01

    The axons of commissural neurons that project from one cochlear nucleus to the other were studied after labeling with anterograde tracer. Injections were made into the dorsal subdivision of the cochlear nucleus in order to restrict labeling only to the group of commissural neurons that gave off collaterals to, or were located in, this subdivision. The number of labeled commissural axons in each injection was correlated with the number of labeled radiate multipolar neurons, suggesting radiate neurons as the predominant origin of the axons. The radiate commissural axons are thick and myelinated, and they exit the dorsal acoustic stria of the injected cochlear nucleus to cross the brainstem in the dorsal half, near the crossing position of the olivocochlear bundle. They enter the opposite cochlear nucleus via the dorsal and ventral acoustic stria and at its medial border. Reconstructions of single axons demonstrate that terminations are mostly in the core and typically within a single subdivision of the cochlear nucleus. Extents of termination range from narrow to broad along both the dorsoventral (i.e., tonotopic) and the rostrocaudal dimensions. In the electron microscope, labeled swellings form synapses that are symmetric (in that there is little postsynaptic density), a characteristic of inhibitory synapses. Our labeled axons do not appear to include excitatory commissural axons that end in edge regions of the nucleus. Radiate commissural axons could mediate the broadband inhibition observed in responses to contralateral sound, and they may balance input from the two ears with a quick time course. Copyright © 2012 Wiley Periodicals, Inc.

  15. Commissural Axons of the Mouse Cochlear Nucleus

    PubMed Central

    Brown, M. Christian; Drottar, Marie; Benson, Thane E.; Darrow, Keith

    2012-01-01

    The axons of commissural neurons that project from one cochlear nucleus to the other were studied after labeling with anterograde tracer. Injections were made into the dorsal subdivision of the cochlear nucleus in order to restrict labeling only to the group of commissural neurons that gave off collaterals to, or were located in, this subdivision. The number of labeled commissural axons in each injection was correlated with the number of labeled radiate multipolar neurons, suggesting radiate neurons as the predominant origin of the axons. The radiate commissural axons are thick and myelinated, and they exit the dorsal acoustic stria of the injected cochlear nucleus to cross the brainstem in the dorsal half, near the crossing position of the olivocochlear bundle. They enter the opposite cochlear nucleus via the dorsal and ventral acoustic stria and at its medial border. Reconstructions of single axons demonstrate that terminations are mostly in the core and typically within a single subdivision of the cochlear nucleus. Extents of termination range from narrow to broad along both the dorso-ventral (i.e. tonotopic) and rostro-caudal dimensions. In the electron microscope, labeled swellings form synapses that are symmetric (in that there is little postsynaptic density), a characteristic of inhibitory synapses. Our labeled axons do not appear to include excitatory commissural axons that end in edge regions of the nucleus. Radiate commissural axons could mediate the broad-band inhibition observed in responses to contralateral sound, and they may balance input from the two ears on a quick time course. PMID:23124982

  16. Determination of the position of nucleus cochlear implant electrodes in the inner ear.

    PubMed

    Skinner, M W; Ketten, D R; Vannier, M W; Gates, G A; Yoffie, R L; Kalender, W A

    1994-09-01

    Accurate determination of intracochlear electrode position in patients with cochlear implants could provide a basis for detecting migration of the implant and could aid in the selection of stimulation parameters for sound processor programming. New computer algorithms for submillimeter resolution and 3-D reconstruction from spiral computed tomographic (CT) scans now make it possible to accurately determine the position of implanted electrodes within the cochlear canal. The accuracy of these algorithms was tested using an electrode array placed in a phantom model. Measurements of electrode length and interelectrode distance from spiral CT scan reconstructions were in close agreement with those from stereo microscopy. Although apparent electrode width was increased on CT scans due to partial volume averaging, a correction factor was developed for measurements from conventional radiographs and an expanded CT absorption value scale added to detect the presence of platinum electrodes and wires. The length of the cochlear canal was calculated from preoperative spiral CT scans for one patient, and the length of insertion of the electrode array was calculated from her postoperative spiral CT scans. The cross-sectional position of electrodes in relation to the outer bony wall and modiolus was measured and plotted as a function of distance with the electrode width correction applied.

  17. Cochlear Implants.

    ERIC Educational Resources Information Center

    Clark, Catherine; Scott, Larry

    This brochure explains what a cochlear implant is, lists the types of individuals with deafness who may be helped by a cochlear implant, describes the process of evaluating people for cochlear implants, discusses the surgical process for implanting the aid, traces the path of sound through the cochlear implant to the brain, notes the costs of…

  18. Cochlear implantation in patients with bilateral cochlear trauma.

    PubMed

    Serin, Gediz Murat; Derinsu, Ufuk; Sari, Murat; Gergin, Ozgül; Ciprut, Ayça; Akdaş, Ferda; Batman, Cağlar

    2010-01-01

    Temporal bone fracture, which involves the otic capsule, can lead to complete loss of auditory and vestibular functions, whereas the patients without fractures may experience profound sensorineural hearing loss due to cochlear concussion. Cochlear implant is indicated in profound sensorineural hearing loss due to cochlear trauma but who still have an intact auditory nerve. This is a retrospective review study. We report 5 cases of postlingually deafened patients caused by cochlear trauma, who underwent cochlear implantation. Preoperative and postoperative hearing performance will be presented. These patients are cochlear implanted after the cochlear trauma in our department between 2001 and 2006. All patients performed very well with their implants, obtained open-set speech understanding. They all became good telephone users after implantation. Their performance in speech understanding was comparable to standard postlingual adult patients implanted. Cochlear implantation is an effective aural rehabilitation in profound sensorineural hearing loss caused by temporal bone trauma. Preoperative temporal bone computed tomography, magnetic resonance imaging, and promontorium stimulation testing are necessary to make decision for the surgery and to determine the side to be implanted. Surgery could be challenging and complicated because of anatomical irregularity. Moreover, fibrosis and partial or total ossification within the cochlea must be expected. Copyright 2010. Published by Elsevier Inc.

  19. Motion of organ of Corti structures in the gerbil cochlear apex, measured with a commercial optical coherence tomography (OCT) system

    NASA Astrophysics Data System (ADS)

    Ravicz, Michael E.; Cho, Nam-Hyun; Maftoon, Nima; Puria, Sunil

    2018-05-01

    Recent developments in Optical Coherence Tomography (OCT) allow measurements of cochlear motions through the bony cochlear wall without holes at spatial resolutions approaching about 10 µm. Measurements to date have been made with custom OCT systems with long development times. We present measurements made with a commercial OCT system driven by custom software (VibOCT) that facilitates near real-time frequency response measurements. The 905-nm wavelength laser and high-speed (100 kHz) camera provide higher axial resolution (3 µm in air) and temporal resolution than previous studies and a sub-nanometer noise floor in air. We gathered anatomical images of the gerbil cochlear apex in vivo at higher resolution than available previously, sufficient to resolve individual outer hair cells, pillar cells, tunnel of Corti and inner sulcus regions. Images from the 3rd apical turn show a bulging of Reissners membrane in vivo that flattened post-mortem with a concomitant reduction in the distance between the Henson cell border and the stria vascularis wall. Vibrometry of the organ of Corti shows a low-pass characteristic in-vivo and post-mortem with a traveling wave-like phase delay similar to a recent study rather than the sharp tuning seen more basally. This system can provide valuable information on cochlear function, which is also useful for the development of detailed cochlear models of the passive and active gerbil apex.

  20. Effect of cochlear nerve electrocautery on the adult cochlear nucleus.

    PubMed

    Iseli, Claire E; Merwin, William H; Klatt-Cromwell, Cristine; Hutson, Kendall A; Ewend, Matthew G; Adunka, Oliver F; Fitzpatrick, Douglas C; Buchman, Craig A

    2015-04-01

    Electrocauterization and subsequent transection of the cochlear nerve induce greater injury to the cochlear nucleus than sharp transection alone. Some studies show that neurofibromatosis Type 2 (NF2) patients fit with auditory brainstem implants (ABIs) fail to achieve speech perception abilities similar to ABI recipients without NF2. Reasons for these differences remain speculative. One hypothesis posits poorer performance to surgically induced trauma to the cochlear nucleus from electrocautery. Sustained electrosurgical depolarization of the cochlear nerve may cause excitotoxic-induced postsynaptic nuclear injury. Equally plausible is that cautery in the vicinity of the cochlear nucleus induces necrosis. The cochlear nerve was transected in anesthetized adult gerbils sharply with or without bipolar electrocautery at varying intensities. Gerbils were perfused at 1, 3, 5, and 7 days postoperatively; their brainstem and cochleas were embedded in paraffin and sectioned at 10 μm. Alternate sections were stained with flourescent markers for neuronal injury or Nissl substance. In additional experiments, anterograde tracers were applied directly to a sectioned eighth nerve to verify that fluorescent-labeled profiles seen were terminating auditory nerve fibers. Cochlear nerve injury was observed from 72 hours postoperatively and was identical across cases regardless of surgical technique. Postsynaptic cochlear nucleus injury was not seen after distal transection of the nerve. By contrast, proximal transection was associated with trauma to the cochlear nucleus. Distal application of bipolar electrocautery seems safe for the cochlear nucleus. Application near the root entry zone must be used cautiously because this may compromise nuclear viability needed to support ABI stimulation.

  1. An Evaluation of the Surgical Trauma to Intracochlear Structures After Insertion of Cochlear Implant Electrode Arrays: A Comparison by Round Window and Antero-Inferior Cochleostomy Techniques.

    PubMed

    Sikka, Kapil; Kairo, Arvind; Singh, Chirom Amit; Roy, T S; Lalwani, Sanjeev; Kumar, Rakesh; Thakar, Alok; Sharma, Suresh C

    2017-09-01

    To evaluate the extent of intracochlear damage by histologic assessment of cadaveric temporal bones after insertion of cochlear implants by: round window approach and cochleostomy approach. Cochlear implantation was performed by transmastoid facial recess approach in 10 human cadaveric temporal bones. In 5 temporal bones, electrode insertion was acheieved by round window approach and in the remaining 5 bones, by cochleostomy approach. The bones were fixed, decalcified, sectioned and studied histologically. Grading of insertion trauma was assessed. In the round window insertion group, 2 bones had to be excluded from the study: one was damaged during handling with electrode extrusion and another bone did not show any demonstrable identifiable cochlear structure. Out of the 3 temporal bones, a total of 35 sections were examined: 24 demonstrated normal cochlea, 4 had basilar membrane bulging and 7 had fracture of bony spiral lamina. In the cochleostomy group, histology of 2 bones had to be discarded due to lack of any identifiable inner ear structures. Out of the 3 bones studied, 18 sections were examined: only 3 were normal, 4 sections had some bulge in spiral lamina and 11 had fracture of bony spiral lamina. The fracture of spiral lamina and bulge of basement membrane proportion is relatively higher if we perform cochleostomy as compared to round window approach. Therefore, round window insertion is relatively less traumatic as compared to cochleostomy. However, our sample size was very small and a study with a larger sample is required to further validate these findings.

  2. Guideline on cochlear implants.

    PubMed

    Manrique, Manuel; Ramos, Ángel; de Paula Vernetta, Carlos; Gil-Carcedo, Elisa; Lassaleta, Luis; Sanchez-Cuadrado, Isabel; Espinosa, Juan Manuel; Batuecas, Ángel; Cenjor, Carlos; Lavilla, María José; Núñez, Faustino; Cavalle, Laura; Huarte, Alicia

    2018-03-26

    In the last decade numerous hospitals have started to work with patients who are candidates for a cochlear implant (CI) and there have been numerous and relevant advances in the treatment of sensorineural hearing loss that extended the indications for cochlear implants. To provide a guideline on cochlear implants to specialists in otorhinolaryngology, other medical specialities, health authorities and society in general. The Scientific Committees of Otology, Otoneurology and Audiology from the Spanish Society of Otolaryngology and Head and Neck Surgery (SEORL-CCC), in a coordinated and agreed way, performed a review of the current state of CI based on the existing regulations and in the scientific publications referenced in the bibliography of the document drafted. The clinical guideline on cochlear implants provides information on: a) Definition and description of Cochlear Implant; b) Indications for cochlear implants; c) Organizational requirements for a cochlear implant programme. A clinical guideline on cochlear implants has been developed by a Committee of Experts of the SEORL-CCC, to help and guide all the health professionals involved in this field of CI in decision-making to treathearing impairment. Copyright © 2018 Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. Publicado por Elsevier España, S.L.U. All rights reserved.

  3. Malignant pheochromocytoma presenting as incapacitating bony pain.

    PubMed

    Tan, Marilyn; Camargo, Carlos A; Mojtahed, Amirkaveh; Mihm, Fred

    2012-04-01

    Among adrenal incidentalomas, pheochromocytomas are rare. Malignant pheochromocytoma is even less common, and it typically presents with classic hormonal symptoms, such as palpitations, labile blood pressures, and headaches. Bony metastasis usually occurs late in disease, but we report an unusual case of incapacitating bony pain as the initial presentation of malignant pheochromocytoma. Our patient is a 70-year-old woman with neurofibromatosis type 1 and a history of primary hyperparathyroidism, who tested negative for the ret mutation. She came to medical attention with chest pain and palpitations and was incidentally found to have an adrenal mass. Serum and urine testing was consistent with pheochromocytoma. Her blood pressure was easily controlled as she awaited elective adrenalectomy; however, she quickly developed severe, diffuse bony pain. She represented with hypercalcemia, spontaneous fractures, and incapacitating pain that required such high doses of pain medications that she had to be intubated. Further imaging and bone marrow biopsy confirmed metastatic neuroendocrine tumor. She received one round of chemotherapy with no change in her bony pain, which was her primary complaint. Unfortunately, her treatment options were limited by the heavy sedation required for comfort, and in the end, it was her bony pain rather than hormonal symptoms that made her disease untreatable. © 2011 The Authors. Pain Practice © 2011 World Institute of Pain.

  4. The bony cartilaginous unit: the missing graft in septorhinoplasty.

    PubMed

    Sazgar, A A

    2016-08-01

    To achieve the desired nasoseptal refinements in septorhinoplasty, sufficient septal cartilage is needed. There are many cases in which septal cartilage is insufficient, especially in revision surgery. To obtain an optimal outcome, a bony cartilaginous unit is proposed as a versatile graft for various parts of the nose. This bony cartilaginous unit is extracted using the open septorhinoplasty approach in which the bilateral septal flaps are elevated over the entire cartilaginous and bony part; however, the cartilaginous septum and posterior bony part are not separated and are removed as an integrated unit. These bony cartilaginous units can be used as various types of grafts at different sites in the nose. In the present study, the bony cartilaginous units were used as caudal extension grafts, spreader grafts, lateral crural strut grafts, and for the closure of septal perforations. This research has shown the advantage of using septal bone in conjunction with cartilage as an integrated unit to correct external nose and septal deformities, especially in cartilage-depleted patients. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  5. Perilymph sampling from the cochlear apex: a reliable method to obtain higher purity perilymph samples from scala tympani.

    PubMed

    Salt, Alec N; Hale, Shane A; Plonkte, Stefan K R

    2006-05-15

    Measurements of drug levels in the fluids of the inner ear are required to establish kinetic parameters and to determine the influence of specific local delivery protocols. For most substances, this requires cochlear fluids samples to be obtained for analysis. When auditory function is of primary interest, the drug level in the perilymph of scala tympani (ST) is most relevant, since drug in this scala has ready access to the auditory sensory cells. In many prior studies, ST perilymph samples have been obtained from the basal turn, either by aspiration through the round window membrane (RWM) or through an opening in the bony wall. A number of studies have demonstrated that such samples are likely to be contaminated with cerebrospinal fluid (CSF). CSF enters the basal turn of ST through the cochlear aqueduct when the bony capsule is perforated or when fluid is aspirated. The degree of sample contamination has, however, not been widely appreciated. Recent studies have shown that perilymph samples taken through the round window membrane are highly contaminated with CSF, with samples greater than 2microL in volume containing more CSF than perilymph. In spite of this knowledge, many groups continue to sample from the base of the cochlea, as it is a well-established method. We have developed an alternative, technically simple method to increase the proportion of ST perilymph in a fluid sample. The sample is taken from the apex of the cochlea, a site that is distant from the cochlear aqueduct. A previous problem with sampling through a perforation in the bone was that the native perilymph rapidly leaked out driven by CSF pressure and was lost to the middle ear space. We therefore developed a procedure to collect all the fluid that emerged from the perforated apex after perforation. We evaluated the method using a marker ion trimethylphenylammonium (TMPA). TMPA was applied to the perilymph of guinea pigs either by RW irrigation or by microinjection into the apical turn. The

  6. Perilymph Sampling from the Cochlear Apex: A Reliable Method to Obtain Higher Purity Perilymph Samples from Scala Tympani

    PubMed Central

    Salt, Alec N.; Hale, Shane A.; Plontke, Stefan K. R.

    2006-01-01

    Measurements of drug levels in the fluids of the inner ear are required to establish kinetic parameters and to determine the influence of specific local delivery protocols. For most substances, this requires cochlear fluids samples to be obtained for analysis. When auditory function is of primary interest, the drug level in the perilymph of scala tympani (ST) is most relevant, since drug in this scala has ready access to the auditory sensory cells. In many prior studies, ST perilymph samples have been obtained from the basal turn, either by aspiration through the round window membrane (RWM) or through an opening in the bony wall. A number of studies have demonstrated that such samples are likely to be contaminated with cerebrospinal fluid (CSF). CSF enters the basal turn of ST through the cochlear aqueduct when the bony capsule is perforated or when fluid is aspirated. The degree of sample contamination has, however, not been widely appreciated. Recent studies have shown that perilymph samples taken through the round window membrane are highly contaminated with CSF, with samples greater than 2 μL in volume containing more CSF than perilymph. In spite of this knowledge, many groups continue to sample from the base of the cochlea, as it is a well-established method. We have developed an alternative, technically simple method to increase the proportion of ST perilymph in a fluid sample. The sample is taken from the apex of the cochlea, a site that is distant from the cochlear aqueduct. A previous problem with sampling through a perforation in the bone was that the native perilymph rapidly leaked out driven by CSF pressure and was lost to the middle ear space. We therefore developed a procedure to collect all the fluid that emerged from the perforated apex after perforation. We evaluated the method using a marker ion trimethylphenylammonium (TMPA). TMPA was applied to the perilymph of guinea pigs either by RW irrigation or by microinjection into the apical turn. The

  7. Bony Regeneration of the Sella after Transsphenoidal Pituitary Surgery.

    PubMed

    Yahia-Cherif, Mehdi; Delpierre, Isabelle; Hassid, Sergio; De Witte, Olivier

    2016-04-01

    The purpose of this study is to demonstrate the possible bony regrowth of the sella after transsphenoidal surgery without any intraoperative sellar reconstruction. Radiologic findings of the sella were reviewed in patients with pituitary tumors treated by transsphenoidal surgery. In 17 patients who had postoperative cranial computed tomography scans, bony regeneration of the sellar floor was evaluated by comparing immediate and late postoperative scans. The bony opening reduction was measured in transverse and sagittal planes. The median bony opening diameter in the transverse plane was 8.8 mm (interquartile range [IQR] 5.7-11.4) on the first scan and 4.2 mm (IQR 0.8-6.8) on the second scan. In the sagittal plane, it was 4.8 mm (IQR 1.8-6.8) on the first scan and 2.9 mm (IQR 1.6-3.9) on the second scan. These changes occurred in a median time of 36 months (IQR 22-42). There was a statistically significant decrease of the bony opening diameters in both the transverse and sagittal planes (P < 0.0001 and P = 0.0004, respectively). Bone regeneration was observed in 16 of the 17 patients (approximately 94%). There is a natural bony regeneration of the sella after transsphenoidal pituitary surgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Cochlear third window in the scala vestibuli: an animal model.

    PubMed

    Preis, Michal; Attias, Joseph; Hadar, Tuvia; Nageris, Ben I

    2009-08-01

    Pathologic third window has been investigated in both animals and humans, with a third window located in the vestibular apparatus, specifically, dehiscence of the superior semicircular canal, serving as the clinical model. The present study sought to examine the effect of a cochlear third window in the scala vestibuli on the auditory thresholds in fat sand rats that have a unique anatomy of the inner ear that allows for easy surgical access. The experiment included 7 healthy 6-month-old fat sand rats (a total of 10 ears). A pathologic third window was induced by drilling a hole in the bony labyrinth over the scala vestibuli, with preservation of the membranous labyrinth. Auditory brainstem responses to high- and low-frequency acoustic stimuli delivered via air and bone conduction were recorded before and after the procedure. In the preoperative auditory brainstem response recordings, air-conduction thresholds (ACTs) to clicks and tone bursts averaged 9 and 10 dB, respectively, and bone-conduction thresholds averaged 4.5 and 2.9 dB, respectively. Postfenestration ACTs averaged 41 and 42.2 dB, and bone-conduction thresholds averaged 1.1 and 4.3 dB. The change in ACT was statistically significant (p < 0.01). The presence of a cochlear third window in the scala vestibuli affects auditory thresholds by causing a decrease in sensitivity to air-conducted sound stimuli. These findings agree with the theoretical model and clinical findings.

  9. Noise-induced cochlear synaptopathy in rhesus monkeys (Macaca mulatta).

    PubMed

    Valero, M D; Burton, J A; Hauser, S N; Hackett, T A; Ramachandran, R; Liberman, M C

    2017-09-01

    Cochlear synaptopathy can result from various insults, including acoustic trauma, aging, ototoxicity, or chronic conductive hearing loss. For example, moderate noise exposure in mice can destroy up to ∼50% of synapses between auditory nerve fibers (ANFs) and inner hair cells (IHCs) without affecting outer hair cells (OHCs) or thresholds, because the synaptopathy occurs first in high-threshold ANFs. However, the fiber loss likely impairs temporal processing and hearing-in-noise, a classic complaint of those with sensorineural hearing loss. Non-human primates appear to be less vulnerable to noise-induced hair-cell loss than rodents, but their susceptibility to synaptopathy has not been studied. Because establishing a non-human primate model may be important in the development of diagnostics and therapeutics, we examined cochlear innervation and the damaging effects of acoustic overexposure in young adult rhesus macaques. Anesthetized animals were exposed bilaterally to narrow-band noise centered at 2 kHz at various sound-pressure levels for 4 h. Cochlear function was assayed for up to 8 weeks following exposure via auditory brainstem responses (ABRs) and otoacoustic emissions (OAEs). A moderate loss of synaptic connections (mean of 12-27% in the basal half of the cochlea) followed temporary threshold shifts (TTS), despite minimal hair-cell loss. A dramatic loss of synapses (mean of 50-75% in the basal half of the cochlea) was seen on IHCs surviving noise exposures that produced permanent threshold shifts (PTS) and widespread hair-cell loss. Higher noise levels were required to produce PTS in macaques compared to rodents, suggesting that primates are less vulnerable to hair-cell loss. However, the phenomenon of noise-induced cochlear synaptopathy in primates is similar to that seen in rodents. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Waardenburg Syndrome: An Unusual Indication of Cochlear Implantation Experienced in 11 Patients.

    PubMed

    Bayrak, Feda; Çatlı, Tolgahan; Atsal, Görkem; Tokat, Taşkın; Olgun, Levent

    2017-08-01

    The aim of this study was to present the surgical findings of children with Waardenburg syndrome (WS) and investigate speech development after cochlear implantation in this unique group of patients. A retrospective chart review of the patients diagnosed with WS and implanted between 1998 and 2015 was performed. Categories of auditory performance (CAP) test were used to assess the auditory skills of these patients. CAP is a nonlinear hierarchical scale used to rate a child's developing auditory abilities. Preoperative test results and intraoperative surgical findings of these patients have been presented. In total, 1835 cases were implanted a tour institution, and 1210 of these were children. Among these implantees, 11 were diagnosed with WS (0.59% of all implantees). Four of the 11 patients showed incomplete partition type 2bony labyrinth abnormality (Mondini deformity) and all patients showed intraoperative gusher during cochleostomy, which was subsided through routine interventions. No other complications occurred during surgery, and all patients showed satisfactory CAP results in the late postoperative period. Our experiences with cochlear implantation in patients with WS showed that the procedure is safe and effective in this group of patients. Surgeons should be aware of possible labyrinth malformations and intraoperative problems such as gusher in these patients. In long term, auditory performances may exhibit satisfactory results with optimal postoperative educational and supportive measures.

  11. Trends in Cochlear Implants

    PubMed Central

    Zeng, Fan-Gang

    2004-01-01

    More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic aspects of cochlear implants, focusing on their psychophysical, speech, music, and cognitive performance. This report also forecasts clinical and research trends related to presurgical evaluation, fitting protocols, signal processing, and postsurgical rehabilitation in cochlear implants. Finally, a future landscape in amplification is presented that requires a unique, yet complementary, contribution from hearing aids, middle ear implants, and cochlear implants to achieve a total solution to the entire spectrum of hearing loss treatment and management. PMID:15247993

  12. Trends in cochlear implants.

    PubMed

    Zeng, Fan-Gang

    2004-01-01

    More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic aspects of cochlear implants, focusing on their psychophysical, speech, music, and cognitive performance. This report also forecasts clinical and research trends related to presurgical evaluation, fitting protocols, signal processing, and postsurgical rehabilitation in cochlear implants. Finally, a future landscape in amplification is presented that requires a unique, yet complementary, contribution from hearing aids, middle ear implants, and cochlear implants to achieve a total solution to the entire spectrum of hearing loss treatment and management.

  13. Limits on normal cochlear 'third' windows provided by previous investigations of additional sound paths into and out of the cat inner ear.

    PubMed

    Rosowski, John J; Bowers, Peter; Nakajima, Hideko H

    2018-03-01

    While most models of cochlear function assume the presence of only two windows into the mammalian cochlea (the oval and round windows), a position that is generally supported by several lines of data, there is evidence for additional sound paths into and out of the inner ear in normal mammals. In this report we review the existing evidence for and against the 'two-window' hypothesis. We then determine how existing data and inner-ear anatomy restrict transmission of sound through these additional sound pathways in cat by utilizing a well-tested model of the cat inner ear, together with anatomical descriptions of the cat cochlear and vestibular aqueducts (potential additional windows to the cochlea). We conclude: (1) The existing data place limits on the size of the cochlear and vestibular aqueducts in cat and are consistent with small volume-velocities through these ducts during ossicular stimulation of the cochlea, (2) the predicted volume velocities produced by aqueducts with diameters half the size of the bony diameters match the functional data within ±10 dB, and (3) these additional volume velocity paths contribute to the inner ear's response to non-acoustic stimulation and conductive pathology. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Cochlear implant revision surgeries in children.

    PubMed

    Amaral, Maria Stella Arantes do; Reis, Ana Cláudia Mirândola B; Massuda, Eduardo T; Hyppolito, Miguel Angelo

    2018-02-16

    The surgery during which the cochlear implant internal device is implanted is not entirely free of risks and may produce problems that will require revision surgeries. To verify the indications for cochlear implantation revision surgery for the cochlear implant internal device, its effectiveness and its correlation with certain variables related to language and hearing. A retrospective study of patients under 18 years submitted to cochlear implant Surgery from 2004 to 2015 in a public hospital in Brazil. Data collected were: age at the time of implantation, gender, etiology of the hearing loss, audiological and oral language characteristics of each patient before and after Cochlear Implant surgery and any need for surgical revision and the reason for it. Two hundred and sixty-five surgeries were performed in 236 patients. Eight patients received a bilateral cochlear implant and 10 patients required revision surgery. Thirty-two surgeries were necessary for these 10 children (1 bilateral cochlear implant), of which 21 were revision surgeries. In 2 children, cochlear implant removal was necessary, without reimplantation, one with cochlear malformation due to incomplete partition type I and another due to trauma. With respect to the cause for revision surgery, of the 8 children who were successfully reimplanted, four had cochlear calcification following meningitis, one followed trauma, one exhibited a facial nerve malformation, one experienced a failure of the cochlear implant internal device and one revision surgery was necessary because the electrode was twisted. The incidence of the cochlear implant revision surgery was 4.23%. The period following the revision surgeries revealed an improvement in the subject's hearing and language performance, indicating that these surgeries are valid in most cases. Copyright © 2018 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  15. Bony injuries in homicide cases (1994-2014). A retrospective study.

    PubMed

    Flieger, Alexander; Kölzer, Sarah C; Plenzig, Stefanie; Heinbuch, Sara; Kettner, Mattias; Ramsthaler, Frank; Verhoff, Marcel A

    2016-09-01

    Even when human skeletal remains are found in contexts indicative of body disposal after homicide, none of the bones may manifest injuries. When skeletons are incomplete, there are two possibilities, the injured bones are missing or none were injured. This leads to the question how frequently bones are injured during homicide, where the injuries tend to be placed, and whether the frequency of injury is related to the type of homicide. To answer these questions, the postmortem reports from all autopsies performed for homicide victims at the Institute of Legal Medicine at the University Hospital in Frankfurt am Main, Germany, between 1994 and 2014, were retrospectively evaluated for bony injuries discovered during autopsy. In 90 cases, a preliminary postmortem computed tomography (pmCT) examination had been performed. The cases were categorized into the following five groups by type of fatal trauma: blunt force, sharp force, gunshot injury, strangulation, or other. In total, the postmortem reports for 897 homicides (527 male, 370 female) were evaluated. The number of victims per trauma category were sharp force, 309; blunt force, 179; gunshot injury, 242; strangulation, 92; and other, 75. Bony injuries had been reported in 70.9 % of the homicides. The "gunshot" category contained the highest proportion of victims with bony injuries (92.6 %). With 80.4 %, the second-highest proportion of victims with bony injuries was in the "blunt force" category, followed by 66.3 % of victims in the "sharp force" group. In contrast, with 53.3 %, the second-lowest proportion of victims with bony injuries was in the "strangulation" category, which contained a preponderance of female victims, followed by 17.3 % of victims with bony injuries in the "other" category. Bony injuries thus occurred in the majority of homicides. Forensic osteological analysis should, therefore, always be performed on badly decomposed human remains. Where necessary, the additional use of visualization

  16. Cochlear Implants Special Issue Article: Vocal Emotion Recognition by Normal-Hearing Listeners and Cochlear Implant Users

    PubMed Central

    Luo, Xin; Fu, Qian-Jie; Galvin, John J.

    2007-01-01

    The present study investigated the ability of normal-hearing listeners and cochlear implant users to recognize vocal emotions. Sentences were produced by 1 male and 1 female talker according to 5 target emotions: angry, anxious, happy, sad, and neutral. Overall amplitude differences between the stimuli were either preserved or normalized. In experiment 1, vocal emotion recognition was measured in normal-hearing and cochlear implant listeners; cochlear implant subjects were tested using their clinically assigned processors. When overall amplitude cues were preserved, normal-hearing listeners achieved near-perfect performance, whereas listeners with cochlear implant recognized less than half of the target emotions. Removing the overall amplitude cues significantly worsened mean normal-hearing and cochlear implant performance. In experiment 2, vocal emotion recognition was measured in listeners with cochlear implant as a function of the number of channels (from 1 to 8) and envelope filter cutoff frequency (50 vs 400 Hz) in experimental speech processors. In experiment 3, vocal emotion recognition was measured in normal-hearing listeners as a function of the number of channels (from 1 to 16) and envelope filter cutoff frequency (50 vs 500 Hz) in acoustic cochlear implant simulations. Results from experiments 2 and 3 showed that both cochlear implant and normal-hearing performance significantly improved as the number of channels or the envelope filter cutoff frequency was increased. The results suggest that spectral, temporal, and overall amplitude cues each contribute to vocal emotion recognition. The poorer cochlear implant performance is most likely attributable to the lack of salient pitch cues and the limited functional spectral resolution. PMID:18003871

  17. Physiopathology of the Cochlear Microcirculation

    PubMed Central

    Shi, Xiaorui

    2011-01-01

    Normal blood supply to the cochlea is critically important for establishing the endocochlear potential and sustaining production of endolymph. Abnormal cochlear microcirculation has long been considered an etiologic factor in noise-induced hearing loss, age-related hearing loss (presbycusis), sudden hearing loss or vestibular function, and Meniere's disease. Knowledge of the mechanisms underlying the pathophysiology of cochlear microcirculation is of fundamental clinical importance. A better understanding of cochlear blood flow (CoBF) will enable more effective management of hearing disorders resulting from aberrant blood flow. This review focuses on recent discoveries and findings related to the physiopathology of the cochlear microvasculature. PMID:21875658

  18. Evaluation of the three-dimensional bony coverage before and after rotational acetabular osteotomy.

    PubMed

    Tanaka, Takeyuki; Moro, Toru; Takatori, Yoshio; Oshima, Hirofumi; Ito, Hideya; Sugita, Naohiko; Mitsuishi, Mamoru; Tanaka, Sakae

    2018-02-26

    Rotational acetabular osteotomy is a type of pelvic osteotomy that involves rotation of the acetabular bone to improve the bony coverage of the femoral head for patients with acetabular dysplasia. Favourable post-operative long-term outcomes have been reported in previous studies. However, there is a paucity of published data regarding three-dimensional bony coverage. The present study investigated the three-dimensional bony coverage of the acetabulum covering the femoral head in hips before and after rotational acetabular osteotomy and in normal hips. The computed tomography data of 40 hip joints (12 joints before and after rotational acetabular osteotomy; 16 normal joints) were analyzed. The three-dimensional bony coverage of each joint was evaluated using original software. The post-operative bony coverage improved significantly compared with pre-operative values. In particular, the anterolateral aspect of the acetabulum tended to be dysplastic in patients with acetabular dysplasia compared to those with normal hip joints. However, greater bony coverage at the anterolateral aspect was obtained after rotational acetabular osteotomy. Meanwhile, the results of the present study may indicate that the bony coverage in the anterior aspect may be excessive. Three-dimensional analysis indicated that rotational acetabular osteotomy achieved favorable bony coverage. Further investigations are necessary to determine the ideal bony coverage after rotational acetabular osteotomy.

  19. A true minimally invasive approach for cochlear implantation: high accuracy in cranial base navigation through flat-panel-based volume computed tomography.

    PubMed

    Majdani, Omid; Bartling, Soenke H; Leinung, Martin; Stöver, Timo; Lenarz, Minoo; Dullin, Christian; Lenarz, Thomas

    2008-02-01

    High-precision intraoperative navigation using high-resolution flat-panel volume computed tomography makes feasible the possibility of minimally invasive cochlear implant surgery, including cochleostomy. Conventional cochlear implant surgery is typically performed via mastoidectomy with facial recess to identify and avoid damage to vital anatomic landmarks. To accomplish this procedure via a minimally invasive approach--without performing mastoidectomy--in a precise fashion, image-guided technology is necessary. With such an approach, surgical time and expertise may be reduced, and hearing preservation may be improved. Flat-panel volume computed tomography was used to scan 4 human temporal bones. A drilling channel was planned preoperatively from the mastoid surface to the round window niche, providing a margin of safety to all functional important structures (e.g., facial nerve, chorda tympani, incus). Postoperatively, computed tomographic imaging and conventional surgical exploration of the drilled route to the cochlea were performed. All 4 specimens showed a cochleostomy located at the scala tympani anterior inferior to the round window. The chorda tympani was damaged in 1 specimen--this was preoperatively planned as a narrow facial recess was encountered. Using flat-panel volume computed tomography for image-guided surgical navigation, we were able to perform minimally invasive cochlear implant surgery defined as a narrow, single-channel mastoidotomy with cochleostomy. Although this finding is preliminary, it is technologically achievable.

  20. Physiopathology of the cochlear microcirculation.

    PubMed

    Shi, Xiaorui

    2011-12-01

    Normal blood supply to the cochlea is critically important for establishing the endocochlear potential and sustaining production of endolymph. Abnormal cochlear microcirculation has long been considered an etiologic factor in noise-induced hearing loss, age-related hearing loss (presbycusis), sudden hearing loss or vestibular function, and Meniere's disease. Knowledge of the mechanisms underlying the pathophysiology of cochlear microcirculation is of fundamental clinical importance. A better understanding of cochlear blood flow (CoBF) will enable more effective management of hearing disorders resulting from aberrant blood flow. This review focuses on recent discoveries and findings related to the physiopathology of the cochlear microvasculature. Published by Elsevier B.V.

  1. Challenging aspects of contemporary cochlear implant electrode array design.

    PubMed

    Mistrík, Pavel; Jolly, Claude; Sieber, Daniel; Hochmair, Ingeborg

    2017-12-01

    A design comparison of current perimodiolar and lateral wall electrode arrays of the cochlear implant (CI) is provided. The focus is on functional features such as acoustic frequency coverage and tonotopic mapping, battery consumption and dynamic range. A traumacity of their insertion is also evaluated. Review of up-to-date literature. Perimodiolar electrode arrays are positioned in the basal turn of the cochlea near the modiolus. They are designed to initiate the action potential in the proximity to the neural soma located in spiral ganglion. On the other hand, lateral wall electrode arrays can be inserted deeper inside the cochlea, as they are located along the lateral wall and such insertion trajectory is less traumatic. This class of arrays targets primarily surviving neural peripheral processes. Due to their larger insertion depth, lateral wall arrays can deliver lower acoustic frequencies in manner better corresponding to cochlear tonotopicity. In fact, spiral ganglion sections containing auditory nerve fibres tuned to low acoustic frequencies are located deeper than 1 and half turn inside the cochlea. For this reason, a significant frequency mismatch might be occurring for apical electrodes in perimodiolar arrays, detrimental to speech perception. Tonal languages such as Mandarin might be therefore better treated with lateral wall arrays. On the other hand, closer proximity to target tissue results in lower psychophysical threshold levels for perimodiolar arrays. However, the maximal comfort level is also lower, paradoxically resulting in narrower dynamic range than that of lateral wall arrays. Battery consumption is comparable for both types of arrays. Lateral wall arrays are less likely to cause trauma to cochlear structures. As the current trend in cochlear implantation is the maximal protection of residual acoustic hearing, the lateral wall arrays seem more suitable for hearing preservation CI surgeries. Future development could focus on combining the

  2. Cochlear implant in Hong Kong Cantonese.

    PubMed

    Tang, S O; Luk, W S; Lau, C C; So, K W; Wong, C M; Yiu, M L; Kwok, C L

    1990-11-01

    Cochlear implant surgery was performed in four Cantonese-speaking postlingually deaf Chinese adults, using the House/3M single channel device. This article outlines the methodology, including preoperative assessment and postoperative rehabilitation; and explains the necessary modifications in speech and audiologic work-up in Cantonese-speaking patients. Salient features of Cantonese phonetics, especially its tonal characteristics, are described. The findings of the study are presented. The results of the cochlear implant would suggest a performance superior to that of the hearing aid. Furthermore, the cochlear implant is able to detect tonal cues. This quality of the cochlear implant may prove to be a valuable asset to a tonal language-speaking cochlear implantee.

  3. Altered vesicular glutamate transporter distributions in the mouse cochlear nucleus following cochlear insult

    PubMed Central

    Heeringa, Amarins N.; Stefanescu, Roxana A.; Raphael, Yehoash; Shore, Susan E.

    2015-01-01

    Vesicular glutamate transporters 1 and 2 (VGLUT1 and VGLUT2) have distinct distributions in the cochlear nucleus that correspond to the sources of the labeled terminals. VGLUT1 is mainly associated with terminals of auditory nerve fibers, whereas VGLUT2 is mainly associated with glutamatergic terminals deriving from other sources that project to the cochlear nucleus (CN), including somatosensory and vestibular terminals. Previous studies in guinea pig have shown that cochlear damage results in a decrease of VGLUT1-labeled puncta and an increase in VGLUT2-labeled puncta. This indicates cross-modal compensation that is of potential importance in somatic tinnitus. To examine whether this effect is consistent across species and to provide a background for future studies, using transgenesis, the current study examines VGLUT expression profiles upon cochlear insult by intracochlear kanamycin injections in the mouse. Intracochlear kanamycin injections abolished ipsilateral ABR responses in all animals and reduced ipsilateral spiral ganglion neuron densities in animals that were sacrificed after four weeks, but not in animals that were sacrificed after three weeks. In all unilaterally deafened animals, VGLUT1 density was decreased in CN regions that receive auditory nerve fiber terminals, i.e. in the deep layer of the dorsal cochlear nucleus (DCN), in the interstitial region where the auditory nerve enters the CN, and in the magnocellular region of the antero- and posteroventral CN. In contrast, density of VGLUT2 expression was upregulated in the fusiform cell layer of the DCN and in the granule cell lamina, which are known to receive somatosensory and vestibular terminals. These results show that a cochlear insult induces cross-modal compensation in the cochlear nucleus of the mouse, confirming previous findings in guinea pig, and that these changes are not dependent on the occurrence of spiral ganglion neuron degeneration. PMID:26705736

  4. Altered vesicular glutamate transporter distributions in the mouse cochlear nucleus following cochlear insult.

    PubMed

    Heeringa, A N; Stefanescu, R A; Raphael, Y; Shore, S E

    2016-02-19

    Vesicular glutamate transporters 1 and 2 (VGLUT1 and VGLUT2) have distinct distributions in the cochlear nucleus that correspond to sources of the labeled terminals. VGLUT1 is mainly associated with terminals of auditory nerve fibers, whereas VGLUT2 is mainly associated with glutamatergic terminals deriving from other sources that project to the cochlear nucleus (CN), including somatosensory and vestibular terminals. Previous studies in guinea pig have shown that cochlear damage results in a decrease of VGLUT1-labeled puncta and an increase in VGLUT2-labeled puncta. This indicates cross-modal compensation that is of potential importance in somatic tinnitus. To examine whether this effect is consistent across species and to provide a background for future studies, using transgenesis, the current study examines VGLUT expression profiles upon cochlear insult by intracochlear kanamycin injections in the mouse. Intracochlear kanamycin injections abolished ipsilateral ABR responses in all animals and reduced ipsilateral spiral ganglion neuron densities in animals that were sacrificed after four weeks, but not in animals that were sacrificed after three weeks. In all unilaterally deafened animals, VGLUT1 density was decreased in CN regions that receive auditory nerve fiber terminals, i.e., in the deep layer of the dorsal cochlear nucleus (DCN), in the interstitial region where the auditory nerve enters the CN, and in the magnocellular region of the antero- and posteroventral CN. In contrast, density of VGLUT2 expression was upregulated in the fusiform cell layer of the DCN and in the granule cell lamina, which are known to receive somatosensory and vestibular terminals. These results show that a cochlear insult induces cross-modal compensation in the cochlear nucleus of the mouse, confirming previous findings in guinea pig, and that these changes are not dependent on the occurrence of spiral ganglion neuron degeneration. Copyright © 2015 IBRO. Published by Elsevier Ltd

  5. Cochlear implants in Waardenburg syndrome.

    PubMed

    Cullen, Robert D; Zdanski, Carlton; Roush, Patricia; Brown, Carolyn; Teagle, Holly; Pillsbury, Harold C; Buchman, Craig

    2006-07-01

    Waardenburg syndrome is an autosomal-dominant syndrome characterized by dystopia canthorum, hyperplasia of the eyebrows, heterochromia irides, a white forelock, and sensorineural hearing loss in 20% to 55% of patients. This patient population accounts for approximately 2% of congenitally deaf children. The purpose of this retrospective case review was to describe the outcomes for those children with Waardenburg syndrome who have undergone cochlear implantation. Pediatric cochlear implant recipients with documented evidence of Waardenburg syndrome underwent retrospective case review. All patients received their cochlear implants at the study institution followed by outpatient auditory habilitation. Charts were reviewed for etiology and duration of deafness, age at time of cochlear implantation, perioperative complications, duration of use, and performance outcomes. Results of standard tests batteries for speech perception and production administered as a part of the patients' auditory habilitation were reviewed. Seven patients with Waardenburg syndrome and cochlear implants were identified. The average age at implantation was 37 months (range, 18-64 months) and the average duration of use was 69 months (range, 12-143 months). All of these patients are active users of their devices and perform very well after implantation. There were no major complications in this small group of patients. Children with congenital sensorineural hearing loss without other comorbidities (e.g., developmental delay, inner ear malformations) perform well when they receive cochlear implantation and auditory habilitation. Patients with Waardenburg syndrome can be expected to have above-average performance after cochlear implantation.

  6. Serotonin projection patterns to the cochlear nucleus.

    PubMed

    Thompson, A M; Thompson, G C

    2001-07-13

    The cochlear nucleus is well known as an obligatory relay center for primary auditory nerve fibers. Perhaps not so well known is the neural input to the cochlear nucleus from cells containing serotonin that reside near the midline in the midbrain raphe region. Although the specific locations of the main, if not sole, sources of serotonin within the dorsal cochlear nucleus subdivision are known to be the dorsal and median raphe nuclei, sources of serotonin located within other cochlear nucleus subdivisions are not currently known. Anterograde tract tracing was used to label fibers originating from the dorsal and median raphe nuclei while fluorescence immunohistochemistry was used to simultaneously label specific serotonin fibers in cat. Biotinylated dextran amine was injected into the dorsal and median raphe nuclei and was visualized with Texas Red, while serotonin was visualized with fluorescein. Thus, double-labeled fibers were unequivocally identified as serotoninergic and originating from one of the labeled neurons within the dorsal and median raphe nuclei. Double-labeled fiber segments, typically of fine caliber with oval varicosities, were observed in many areas of the cochlear nucleus. They were found in the molecular layer of the dorsal cochlear nucleus, in the small cell cap region, and in the granule cell and external regions of the cochlear nuclei, bilaterally, of all cats. However, the density of these double-labeled fiber segments varied considerably depending upon the exact region in which they were found. Fiber segments were most dense in the dorsal cochlear nucleus (especially in the molecular layer) and the large spherical cell area of the anteroventral cochlear nucleus; they were moderately dense in the small cell cap region; and fiber segments were least dense in the octopus and multipolar cell regions of the posteroventral cochlear nucleus. Because of the presence of labeled fiber segments in subdivisions of the cochlear nucleus other than the

  7. Sound-direction identification with bilateral cochlear implants.

    PubMed

    Neuman, Arlene C; Haravon, Anita; Sislian, Nicole; Waltzman, Susan B

    2007-02-01

    The purpose of this study was to compare the accuracy of sound-direction identification in the horizontal plane by bilateral cochlear implant users when localization was measured with pink noise and with speech stimuli. Eight adults who were bilateral users of Nucleus 24 Contour devices participated in the study. All had received implants in both ears in a single surgery. Sound-direction identification was measured in a large classroom by using a nine-loudspeaker array. Localization was tested in three listening conditions (bilateral cochlear implants, left cochlear implant, and right cochlear implant), using two different stimuli (a speech stimulus and pink noise bursts) in a repeated-measures design. Sound-direction identification accuracy was significantly better when using two implants than when using a single implant. The mean root-mean-square error was 29 degrees for the bilateral condition, 54 degrees for the left cochlear implant, and 46.5 degrees for the right cochlear implant condition. Unilateral accuracy was similar for right cochlear implant and left cochlear implant performance. Sound-direction identification performance was similar for speech and pink noise stimuli. The data obtained in this study add to the growing body of evidence that sound-direction identification with bilateral cochlear implants is better than with a single implant. The similarity in localization performance obtained with the speech and pink noise supports the use of either stimulus for measuring sound-direction identification.

  8. Evaluation of the tripolar electrode stimulation method by numerical analysis and animal experiments for cochlear implants.

    PubMed

    Miyoshi, S; Sakajiri, M; Ifukube, T; Matsushima, J

    1997-01-01

    We have proposed the Tripolar Electrode Stimulation Method (TESM) which may enable us to narrow the stimulation region and to move continuously the stimulation site for the cochlear implants. We evaluated whether or not TESM works according to a theory based on numerical analysis using the auditory nerve fiber model. In this simulation, the sum of the excited model fibers were compared with the compound actions potentials obtained from animal experiments. As a result, this experiment showed that TESM could narrow a stimulation region by controlling the sum of the currents emitted from the electrodes on both sides, and continuously move a stimulation site by changing the ratio of the currents emitted from the electrodes on both sides.

  9. Cochlear implants and medical tourism.

    PubMed

    McKinnon, Brian J; Bhatt, Nishant

    2010-09-01

    To compare the costs of medical tourism in cochlear implant surgery performed in India as compared to the United States. In addition, the cost savings of obtaining cochlear implant surgery in India were compare d to those of other surgical interventions obtained as a medical tourist. Searches were conducted on Medline and Google using the search terms: 'medical tourism', 'medical offshoring', 'medical outsourcing', 'cochlear implants' and 'cochlear implantation'. The information regarding cost of medical treatment was obtained from personal communication with individuals familiar with India's cochlear implantation medical tourism industry. The range of cost depended on length of stay as well as the device chosen. Generally the cost, inclusive of travel, surgery and device, was in the range of $21,000-30,000, as compared to a cost range of $40,000-$60,000 in the US. With the escalating cost of healthcare in the United States, it is not surprising that some patients would seek to obtain surgical care overseas at a fraction of the cost. Participants in medical tourism often have financial resources, but lack health insurance coverage. While cardiovascular and orthopedic surgery performed outside the United States in India at centers that cater to medical tourists are often performed at one-quarter to one-third of the cost that would have been paid in the United States, the cost differential for cochlear implants is not nearly as favorable.

  10. Cochlear implants: system design, integration, and evaluation.

    PubMed

    Zeng, Fan-Gang; Rebscher, Stephen; Harrison, William; Sun, Xiaoan; Feng, Haihong

    2008-01-01

    As the most successful neural prosthesis, cochlear implants have provided partial hearing to more than 120000 persons worldwide; half of which being pediatric users who are able to develop nearly normal language. Biomedical engineers have played a central role in the design, integration and evaluation of the cochlear implant system, but the overall success is a result of collaborative work with physiologists, psychologists, physicians, educators, and entrepreneurs. This review presents broad yet in-depth academic and industrial perspectives on the underlying research and ongoing development of cochlear implants. The introduction accounts for major events and advances in cochlear implants, including dynamic interplays among engineers, scientists, physicians, and policy makers. The review takes a system approach to address critical issues in cochlear implant research and development. First, the cochlear implant system design and specifications are laid out. Second, the design goals, principles, and methods of the subsystem components are identified from the external speech processor and radio frequency transmission link to the internal receiver, stimulator and electrode arrays. Third, system integration and functional evaluation are presented with respect to safety, reliability, and challenges facing the present and future cochlear implant designers and users. Finally, issues beyond cochlear implants are discussed to address treatment options for the entire spectrum of hearing impairment as well as to use the cochlear implant as a model to design and evaluate other similar neural prostheses such as vestibular and retinal implants.

  11. Questioning cochlear amplification

    NASA Astrophysics Data System (ADS)

    van der Heijden, Marcel; Versteegh, Corstiaen P. C.

    2015-12-01

    Thirty years ago it was hypothesized that motile processes inject mechanical energy into cochlear traveling waves. This mechanical amplification, alternatively described as negative damping, is invoked to explain both the sensitivity and the nonlinear compression of cochlear responses. There is a recent trend to present cochlear amplification as an established fact, even though the evidence is at most circumstantial and several thorny problems have remained unresolved. We analyze several of these issues, and present new basilar membrane recordings that allowed us to quantify cochlear energy flow. Specifically, we address the following questions: (1) Does auditory sensitivity require narrowband amplification? (2) Has the "RC problem" (lowpass filtering of outer hair cell receptor potential) been resolved? (3) Can OHC motility improve auditory sensitivity? (4) Is there a net power gain between neighboring locations on the basilar membrane? The analyses indicate that mechanical amplification in the cochlea is neither necessary nor useful, and that realizing it by known forms of motility would reduce sensitivity rather than enhance it. Finally, our experimental data show that the peaking of the traveling wave is realized by focusing the acoustic energy rather than amplifying it. (Abbreviations. BM: basilar membrane; CF: characteristic frequency; IHC: inner hair cell; ME: middle ear; MT; mechanotransducer; OHC: outer hair cell; SPL: sound pressure level.)

  12. Cochlear microphonic broad tuning curves

    NASA Astrophysics Data System (ADS)

    Ayat, Mohammad; Teal, Paul D.; Searchfield, Grant D.; Razali, Najwani

    2015-12-01

    It is known that the cochlear microphonic voltage exhibits much broader tuning than does the basilar membrane motion. The most commonly used explanation for this is that when an electrode is inserted at a particular point inside the scala media, the microphonic potentials of neighbouring hair cells have different phases, leading to cancelation at the electrodes location. In situ recording of functioning outer hair cells (OHCs) for investigating this hypothesis is exceptionally difficult. Therefore, to investigate the discrepancy between the tuning curves of the basilar membrane and those of the cochlear microphonic, and the effect of phase cancellation of adjacent hair cells on the broadness of the cochlear microphonic tuning curves, we use an electromechanical model of the cochlea to devise an experiment. We explore the effect of adjacent hair cells (i.e., longitudinal phase cancellation) on the broadness of the cochlear microphonic tuning curves in different locations. The results of the experiment indicate that active longitudinal coupling (i.e., coupling with active adjacent outer hair cells) only slightly changes the broadness of the CM tuning curves. The results also demonstrate that there is a π phase difference between the potentials produced by the hair bundle and the soma near the place associated with the characteristic frequency based on place-frequency maps (i.e., the best place). We suggest that the transversal phase cancellation (caused by the phase difference between the hair bundle and the soma) plays a far more important role than longitudinal phase cancellation in the broadness of the cochlear microphonic tuning curves. Moreover, by increasing the modelled longitudinal resistance resulting the cochlear microphonic curves exhibiting sharper tuning. The results of the simulations suggest that the passive network of the organ of Corti determines the phase difference between the hair bundle and soma, and hence determines the sharpness of the

  13. Parental expectations and outcomes of pediatric cochlear implantation.

    PubMed

    Piazza, Elizabeth; Kandathil, Cherian; Carron, Jeffrey D

    2009-10-01

    Cochlear implants have been used with increasing frequency over the past twenty years, including very young patients. To determine if parents are satisfied with their children's performance after cochlear implantation. Survey mailed to parents of children receiving cochlear implants. 31 questionnaires were returned out of 69 mailed (45 %). The vast majority of responding parents felt that their children benefited substantially from cochlear implant surgery. Cochlear implantation is effective in helping children develop auditory-oral communication skills. Access to auditory/oral communication programs in this state remains an obstacle in postoperative habilitation.

  14. Cochlear Implants:System Design, Integration and Evaluation

    PubMed Central

    Rebscher, Stephen; Harrison, William V.; Sun, Xiaoan; Feng, Haihong

    2009-01-01

    As the most successful neural prosthesis, cochlear implants have provided partial hearing to more than 120,000 persons worldwide; half of which being pediatric users who are able to develop nearly normal language. Biomedical engineers have played a central role in the design, integration and evaluation of the cochlear implant system, but the overall success is a result of collaborative work with physiologists, psychologists, physicians, educators, and entrepreneurs. This review presents broad yet in-depth academic and industrial perspectives on the underlying research and ongoing development of cochlear implants. The introduction accounts for major events and advances in cochlear implants, including dynamic interplays among engineers, scientists, physicians, and policy makers. The review takes a system approach to address critical issues from design and specifications to integration and evaluation. First, the cochlear implant system design and specifications are laid out. Second, the design goals, principles, and methods of the subsystem components are identified from the external speech processor and radio frequency transmission link to the internal receiver, stimulator and electrode arrays. Third, system integration and functional evaluation are presented with respect to safety, reliability, and challenges facing the present and future cochlear implant designers and users. Finally, issues beyond cochlear implants are discussed to address treatment options for the entire spectrum of hearing impairment as well as to use the cochlear implant as a model to design and evaluate other similar neural prostheses such as vestibular and retinal implants. PMID:19946565

  15. Importance of cochlear health for implant function.

    PubMed

    Pfingst, Bryan E; Zhou, Ning; Colesa, Deborah J; Watts, Melissa M; Strahl, Stefan B; Garadat, Soha N; Schvartz-Leyzac, Kara C; Budenz, Cameron L; Raphael, Yehoash; Zwolan, Teresa A

    2015-04-01

    Amazing progress has been made in providing useful hearing to hearing-impaired individuals using cochlear implants, but challenges remain. One such challenge is understanding the effects of partial degeneration of the auditory nerve, the target of cochlear implant stimulation. Here we review studies from our human and animal laboratories aimed at characterizing the health of the implanted cochlea and the auditory nerve. We use the data on cochlear and neural health to guide rehabilitation strategies. The data also motivate the development of tissue-engineering procedures to preserve or build a healthy cochlea and improve performance obtained by cochlear implant recipients or eventually replace the need for a cochlear implant. This article is part of a Special Issue entitled . Copyright © 2014 Elsevier B.V. All rights reserved.

  16. [Cochlear implantation through the middle fossa approach].

    PubMed

    Szyfter, W; Colletti, V; Pruszewicz, A; Kopeć, T; Szymiec, E; Kawczyński, M; Karlik, M

    2001-01-01

    The inner part of cochlear implant is inserted into inner ear during surgery through mastoid and middle ear. It is a classical method, used in the majority cochlear centers in the world. This is not a suitable method in case of chronic otitis media and middle ear malformation. In these cases Colletti proposed the middle fossa approach and cochlear implant insertion omitting middle ear structures. In patient with bilateral chronic otitis media underwent a few ears operations without obtaining dry postoperative cavity. Cochlear implantation through the middle fossa approach was performed in this patient. The bone fenster was cut, temporal lobe was bent and petrosus pyramid upper surface was exposed. When the superficial petrosal greater nerve, facial nerve and arcuate eminence were localised, the cochlear was open in the basal turn and electrode were inserted. The patient achieves good results in the postoperative speech rehabilitation. It confirmed Colletti tesis that deeper electrode insertion in the cochlear implantation through the middle fossa approach enable use of low and middle frequencies, which are very important in speech understanding.

  17. Disorders of cochlear blood flow.

    PubMed

    Nakashima, Tsutomu; Naganawa, Shinji; Sone, Michihiko; Tominaga, Mitsuo; Hayashi, Hideo; Yamamoto, Hiroshi; Liu, Xiuli; Nuttall, Alfred L

    2003-09-01

    The cochlea is principally supplied from the inner ear artery (labyrinthine artery), which is usually a branch of the anterior inferior cerebellar artery. Cochlear blood flow is a function of cochlear perfusion pressure, which is calculated as the difference between mean arterial blood pressure and inner ear fluid pressure. Many otologic disorders such as noise-induced hearing loss, endolymphatic hydrops and presbycusis are suspected of being related to alterations in cochlear blood flow. However, the human cochlea is not easily accessible for investigation because this delicate sensory organ is hidden deep in the temporal bone. In patients with sensorineural hearing loss, magnetic resonance imaging, laser-Doppler flowmetry and ultrasonography have been used to investigate the status of cochlear blood flow. There have been many reports of hearing loss that were considered to be caused by blood flow disturbance in the cochlea. However, direct evidence of blood flow disturbance in the cochlea is still lacking in most of the cases.

  18. Progress in Cochlear Physiology after Békésy

    PubMed Central

    Guinan, John J.; Salt, Alec; Cheatham, Mary Ann

    2012-01-01

    In the fifty years since Békésy was awarded the Nobel Prize, cochlear physiology has blossomed. Many topics that are now current are things Békésy could not have imagined. In this review we start by describing progress in understanding the origin of cochlear gross potentials, particularly the cochlear microphonic, an area in which Békésy had extensive experience. We then review progress in areas of cochlear physiology that were mostly unknown to Békésy, including: (1) stereocilia mechano-electrical transduction, force production, and response amplification, (2) outer hair cell (OHC) somatic motility and its molecular basis in prestin, (3) cochlear amplification and related micromechanics, including the evidence that prestin is the main motor for cochlear amplification, (4) the influence of the tectorial membrane, (5) cochlear micromechanics and the mechanical drives to inner hair cell stereocilia, (6) otoacoustic emissions, and (7) olivocochlear efferents and their influence on cochlear physiology. We then return to a subject that Békésy knew well: cochlear fluids and standing currents, as well as our present understanding of energy dependence on the lateral wall of the cochlea. Finally, we touch on cochlear pathologies including noise damage and aging, with an emphasis on where the field might go in the future. PMID:22633944

  19. Bony eminence on the middle cranial fossa corresponding to the temporomandibular joint.

    PubMed

    Tsunoda, Atsunobu; Sumi, Takuro; Shirakura, Satoshi; Kishimoto, Seiji; Akita, Keiichi

    2007-07-01

    We report a nameless bony eminence over the temporomandibular joint (TMJ) and its possible clinical significance. Forty-two half heads of 21 UK Caucasian cadavers (61-95 years old, mean 84.3 +/- 8.2 years, male:female = 11:10) were used to investigate the surface of the middle cranial fossa (MCF) over the TMJ. The thickness of the bony roof of the glenoid fossa was also measured. A bony eminence over the glenoid fossa was observed in half of the specimens. Some showed a complete oval bulge, which completely reflected the contour of the glenoid fossa. The others showed a bony bulge, which partially reflected that contour. The mean (+/-SD) thickness of the bone in the roof of glenoid fossa was 1.5 +/- 1.2 mm. The mean bony thickness of specimens showing the eminence was 0.8 +/- 0.5 mm, whereas it was 2.3 +/- 1.2 mm in specimens without an eminence. These differences were statistically significant (P < 0.01). The osteological features we describe may be relevant to certain clinical problems. Traumatic dislocation of mandibular condyle, for example, might relate to a weakness of the glenoid fossa. Copyright 2006 Wiley-Liss, Inc.

  20. Drug delivery into the cochlear apex: Improved control to sequentially affect finely spaced regions along the entire length of the cochlear spiral.

    PubMed

    Lichtenhan, J T; Hartsock, J; Dornhoffer, J R; Donovan, K M; Salt, A N

    2016-11-01

    Administering pharmaceuticals to the scala tympani of the inner ear is a common approach to study cochlear physiology and mechanics. We present here a novel method for in vivo drug delivery in a controlled manner to sealed ears. Injections of ototoxic solutions were applied from a pipette sealed into a fenestra in the cochlear apex, progressively driving solutions along the length of scala tympani toward the cochlear aqueduct at the base. Drugs can be delivered rapidly or slowly. In this report we focus on slow delivery in which the injection rate is automatically adjusted to account for varying cross sectional area of the scala tympani, therefore driving a solution front at uniform rate. Objective measurements originating from finely spaced, low- to high-characteristic cochlear frequency places were sequentially affected. Comparison with existing methods(s): Controlled administration of pharmaceuticals into the cochlear apex overcomes a number of serious limitations of previously established methods such as cochlear perfusions with an injection pipette in the cochlear base: The drug concentration achieved is more precisely controlled, drug concentrations remain in scala tympani and are not rapidly washed out by cerebrospinal fluid flow, and the entire length of the cochlear spiral can be treated quickly or slowly with time. Controlled administration of solutions into the cochlear apex can be a powerful approach to sequentially effect objective measurements originating from finely spaced cochlear regions and allows, for the first time, the spatial origin of CAPs to be objectively defined. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Drug delivery into the cochlear apex: Improved control to sequentially affect finely spaced regions along the entire length of the cochlear spiral

    PubMed Central

    Lichtenhan, JT; Hartsock, J; Dornhoffer, JR; Donovan, KM; Salt, AN

    2016-01-01

    Background Administering pharmaceuticals to the scala tympani of the inner ear is a common approach to study cochlear physiology and mechanics. We present here a novel method for in vivo drug delivery in a controlled manner to sealed ears. New method Injections of ototoxic solutions were applied from a pipette sealed into a fenestra in the cochlear apex, progressively driving solutions along the length of scala tympani toward the cochlear aqueduct at the base. Drugs can be delivered rapidly or slowly. In this report we focus on slow delivery in which the injection rate is automatically adjusted to account for varying cross sectional area of the scala tympani, therefore driving a solution front at uniform rate. Results Objective measurements originating from finely spaced, low- to high-characteristic cochlear frequency places were sequentially affected. Comparison with existing methods(s): Controlled administration of pharmaceuticals into the cochlear apex overcomes a number of serious limitations of previously established methods such as cochlear perfusions with an injection pipette in the cochlear base: The drug concentration achieved is more precisely controlled, drug concentrations remain in scala tympani and are not rapidly washed out by cerebrospinal fluid flow, and the entire length of the cochlear spiral can be treated quickly or slowly with time. Conclusions Controlled administration of solutions into the cochlear apex can be a powerful approach to sequentially effect objective measurements originating from finely spaced cochlear regions and allows, for the first time, the spatial origin of CAPs to be objectively defined. PMID:27506463

  2. Fgf10 is required for specification of non-sensory regions of the cochlear epithelium

    PubMed Central

    Urness, Lisa D.; Wang, Xiaofen; Shibata, Shumei; Ohyama, Takahiro; Mansour, Suzanne L.

    2015-01-01

    The vertebrate inner ear is a morphologically complex sensory organ comprised of two compartments, the dorsal vestibular apparatus and the ventral cochlear duct, required for motion and sound detection, respectively. Fgf10, in addition to Fgf3, is necessary for the earliest stage of otic placode induction, but continued expression of Fgf10 in the developing otic epithelium, including the prosensory domain and later in Kolliker’s organ, suggests additional roles for this gene during morphogenesis of the labyrinth. While loss of Fgf10 was implicated previously in semicircular canal agenesis, we show that Fgf10−/+ embryos also exhibit a reduction or absence of the posterior semicircular canal, revealing a dosage-sensitive requirement for FGF10 in vestibular development. In addition, we show that Fgf10−/− embryos have previously unappreciated defects of cochlear morphogenesis, including a somewhat shortened duct, and, surprisingly, a substantially narrower duct. The mutant cochlear epithelium lacks Reissner’s membrane and a large portion of the outer sulcus--two non-contiguous, non-sensory domains. Marker gene analyses revealed effects on Reissner’s membrane as early as E12.5–E13.5 and on the outer sulcus by E15.5, stages when Fgf10 is expressed in close proximity to Fgfr2b, but these effects were not accompanied by changes in epithelial cell proliferation or death. These data indicate a dual role for Fgf10 in cochlear development: to regulate outgrowth of the duct and subsequently as a bidirectional signal that sequentially specifies Reissner’s membrane and outer sulcus non-sensory domains. These findings may help to explain the hearing loss sometimes observed in LADD syndrome subjects with FGF10 mutations. PMID:25624266

  3. One-Step Preservation and Decalcification of Bony Tissue for Molecular Profiling.

    PubMed

    Mueller, Claudius; Harpole, Michael G; Espina, Virginia

    2017-01-01

    Bone metastasis from primary cancer sites creates diagnostic and therapeutic challenges. Calcified bone is difficult to biopsy due to tissue hardness and patient discomfort, thus limiting the frequency and availability of bone/bone marrow biopsy material for molecular profiling. In addition, bony tissue must be demineralized (decalcified) prior to histomorphologic analysis. Decalcification processes rely on three main principles: (a) solubility of calcium salts in an acid, such as formic or nitric acid; (b) calcium chelation with ethylenediaminetetraacetic acid (EDTA); or (c) ion-exchange resins in a weak acid. A major roadblock in molecular profiling of bony tissue has been the lack of a suitable demineralization process that preserves histomorphology of calcified and soft tissue elements while also preserving phosphoproteins and nucleic acids. In this chapter, we describe general issues relevant to specimen collection and preservation of osseous tissue for molecular profiling. We provide two protocols: (a) one-step preservation of tissue histomorphology and proteins and posttranslational modifications, with simultaneous decalcification of bony tissue, and (b) ethanol-based tissue processing for TheraLin-fixed bony tissue.

  4. Phylogenetic classification of bony fishes.

    PubMed

    Betancur-R, Ricardo; Wiley, Edward O; Arratia, Gloria; Acero, Arturo; Bailly, Nicolas; Miya, Masaki; Lecointre, Guillaume; Ortí, Guillermo

    2017-07-06

    Fish classifications, as those of most other taxonomic groups, are being transformed drastically as new molecular phylogenies provide support for natural groups that were unanticipated by previous studies. A brief review of the main criteria used by ichthyologists to define their classifications during the last 50 years, however, reveals slow progress towards using an explicit phylogenetic framework. Instead, the trend has been to rely, in varying degrees, on deep-rooted anatomical concepts and authority, often mixing taxa with explicit phylogenetic support with arbitrary groupings. Two leading sources in ichthyology frequently used for fish classifications (JS Nelson's volumes of Fishes of the World and W. Eschmeyer's Catalog of Fishes) fail to adopt a global phylogenetic framework despite much recent progress made towards the resolution of the fish Tree of Life. The first explicit phylogenetic classification of bony fishes was published in 2013, based on a comprehensive molecular phylogeny ( www.deepfin.org ). We here update the first version of that classification by incorporating the most recent phylogenetic results. The updated classification presented here is based on phylogenies inferred using molecular and genomic data for nearly 2000 fishes. A total of 72 orders (and 79 suborders) are recognized in this version, compared with 66 orders in version 1. The phylogeny resolves placement of 410 families, or ~80% of the total of 514 families of bony fishes currently recognized. The ordinal status of 30 percomorph families included in this study, however, remains uncertain (incertae sedis in the series Carangaria, Ovalentaria, or Eupercaria). Comments to support taxonomic decisions and comparisons with conflicting taxonomic groups proposed by others are presented. We also highlight cases were morphological support exist for the groups being classified. This version of the phylogenetic classification of bony fishes is substantially improved, providing resolution

  5. Quantification of solute entry into cochlear perilymph through the round window membrane.

    PubMed

    Salt, A N; Ma, Y

    2001-04-01

    The administration of drugs to the inner ear via the round window membrane is becoming more widely used for both clinical and experimental purposes. The actual drug levels achieved in different regions of the inner ear by this method have not been established. The present study has made use of simulations of solute movements in the cochlear fluids to describe the distribution of a marker solute in the guinea pig cochlear fluid spaces. Simulation parameters were derived from experimental measurements using a marker ion, trimethylphenylammonium (TMPA). The distribution of this ion in the cochlea was monitored without volume disturbance using TMPA-selective microelectrodes sealed into the first and second turns of scala tympani (ST). TMPA was applied to perilymph by irrigation of the intact round window membrane with 2 mM solution. At the end of a 90 min application period, TMPA in the first turn, 1.4 mm from the base of ST, reached an average concentration of 330 microM (standard deviation (S.D.) 147 microM, n = 8). TMPA in the second turn, 7.5 mm from the base of ST reached a concentration of 15 microM (S.D. 33 microM, n = 5). The measured time courses of TMPA concentration change were interpreted using the Washington University Cochlear Fluids Simulator (V 1.4), a public-domain program available on the internet at http ://oto.wustl.edu/cochlea/. Simulations with parameters producing concentration time courses comparable to those measured were: (1) round window permeability: 1.9 x 10(-80 cm/s; (2) ST clearance half-time: 60 min; (3) longitudinal perilymph flow rate: 4.4 nl/min, directed from base to apex. Solute concentrations in apical regions of the cochlea were found to be determined primarily by the rate at which the solute diffuses, balanced by the rate of clearance of the solute from perilymph. Longitudinal perilymph flow was not an important factor in solute distribution unless the bony otic capsule was perforated, which rapidly caused substantial changes to

  6. What Does Music Sound Like for a Cochlear Implant User?

    PubMed

    Jiam, Nicole T; Caldwell, Meredith T; Limb, Charles J

    2017-09-01

    Cochlear implant research and product development over the past 40 years have been heavily focused on speech comprehension with little emphasis on music listening and enjoyment. The relatively little understanding of how music sounds in a cochlear implant user stands in stark contrast to the overall degree of importance the public places on music and quality of life. The purpose of this article is to describe what music sounds like to cochlear implant users, using a combination of existing research studies and listener descriptions. We examined the published literature on music perception in cochlear implant users, particularly postlingual cochlear implant users, with an emphasis on the primary elements of music and recorded music. Additionally, we administered an informal survey to cochlear implant users to gather first-hand descriptions of music listening experience and satisfaction from the cochlear implant population. Limitations in cochlear implant technology lead to a music listening experience that is significantly distorted compared with that of normal hearing listeners. On the basis of many studies and sources, we describe how music is frequently perceived as out-of-tune, dissonant, indistinct, emotionless, and weak in bass frequencies, especially for postlingual cochlear implant users-which may in part explain why music enjoyment and participation levels are lower after implantation. Additionally, cochlear implant users report difficulty in specific musical contexts based on factors including but not limited to genre, presence of lyrics, timbres (woodwinds, brass, instrument families), and complexity of the perceived music. Future research and cochlear implant development should target these areas as parameters for improvement in cochlear implant-mediated music perception.

  7. Melodic contour identification by cochlear implant listeners.

    PubMed

    Galvin, John J; Fu, Qian-Jie; Nogaki, Geraldine

    2007-06-01

    While the cochlear implant provides many deaf patients with good speech understanding in quiet, music perception and appreciation with the cochlear implant remains a major challenge for most cochlear implant users. The present study investigated whether a closed-set melodic contour identification (MCI) task could be used to quantify cochlear implant users' ability to recognize musical melodies and whether MCI performance could be improved with moderate auditory training. The present study also compared MCI performance with familiar melody identification (FMI) performance, with and without MCI training. For the MCI task, test stimuli were melodic contours composed of 5 notes of equal duration whose frequencies corresponded to musical intervals. The interval between successive notes in each contour was varied between 1 and 5 semitones; the "root note" of the contours was also varied (A3, A4, and A5). Nine distinct musical patterns were generated for each interval and root note condition, resulting in a total of 135 musical contours. The identification of these melodic contours was measured in 11 cochlear implant users. FMI was also evaluated in the same subjects; recognition of 12 familiar melodies was tested with and without rhythm cues. MCI was also trained in 6 subjects, using custom software and melodic contours presented in a different frequency range from that used for testing. Results showed that MCI recognition performance was highly variable among cochlear implant users, ranging from 14% to 91% correct. For most subjects, MCI performance improved as the number of semitones between successive notes was increased; performance was slightly lower for the A3 root note condition. Mean FMI performance was 58% correct when rhythm cues were preserved and 29% correct when rhythm cues were removed. Statistical analyses revealed no significant correlation between MCI performance and FMI performance (with or without rhythmic cues). However, MCI performance was

  8. Cochlear Implantation in Older Adults

    PubMed Central

    Lin, Frank R.; Chien, Wade W.; Li, Lingsheng; Niparko, John K.; Francis, Howard W.

    2012-01-01

    Cochlear implants allow individuals with severe-to-profound hearing loss access to sound and spoken language. The number of older adults in the United States who are potential candidates for cochlear implantation is approximately 150,000 and will continue to increase with the aging of the population. Should cochlear implantation (CI) be routinely recommended for these older adults, and do these individuals benefit from CI? We reviewed our 12 year experience with cochlear implantation in adults ≥60 years (n = 445) at Johns Hopkins to investigate the impact of CI on speech understanding and to identify factors associated with speech performance. Complete data on speech outcomes at baseline and 1 year post-CI were available for 83 individuals. Our results demonstrate that cochlear implantation in adults ≥60 years consistently improved speech understanding scores with a mean increase of 60. 0% (S. D. 24. 1) on HINT sentences in quiet . The magnitude of the gain in speech scores was negatively associated with age at implantation such that for every increasing year of age at CI the gain in speech scores was 1. 3 percentage points less (95% CI: 0. 6 – 1. 9) after adjusting for age at hearing loss onset. Conversely, individuals with higher pre-CI speech scores (HINT scores between 40–60%) had significantly greater post-CI speech scores by a mean of 10. 0 percentage points (95% CI: 0. 4 – 19. 6) than those with lower pre-CI speech scores (HINT <40%) after adjusting for age at CI and age at hearing loss onset. These results suggest that older adult CI candidates who are younger at implantation and with higher preoperative speech scores obtain the highest speech understanding scores after cochlear implantation with possible implications for current Medicare policy. Finally, we provide an extended discussion of the epidemiology and impact of hearing loss in older adults. Future research of CI in older adults should expand beyond simple speech outcomes to take into

  9. New Criteria of Indication and Selection of Patients to Cochlear Implant

    PubMed Central

    Sampaio, André L. L.; Araújo, Mercêdes F. S.; Oliveira, Carlos A. C. P.

    2011-01-01

    Numerous changes continue to occur in cochlear implant candidacy. In general, these have been accompanied by concomitant and satisfactory changes in surgical techniques. Together, this has advanced the utility and safety of cochlear implantation. Most devices are now approved for use in patients with severe to profound unilateral hearing loss rather then the prior requirement of a bilateral profound loss. Furthermore, studies have begun utilizing short electrode arrays for shallow insertion in patients with considerable low-frequency residual hearing. This technique will allow the recipient to continue to use acoustically amplified hearing for the low frequencies simultaneously with a cochlear implant for the high frequencies. The advances in design of, and indications for, cochlear implants have been matched by improvements in surgical techniques and decrease in complications. The resulting improvements in safety and efficacy have further encouraged the use of these devices. This paper will review the new concepts in the candidacy of cochlear implant. Medline data base was used to search articles dealing with the following topics: cochlear implant in younger children, cochlear implant and hearing preservation, cochlear implant for unilateral deafness and tinnitus, genetic hearing loss and cochlear implant, bilateral cochlear implant, neuropathy and cochlear implant and neural plasticity, and the selection of patients for cochlear implant. PMID:22013448

  10. Remote programming of cochlear implants: a telecommunications model.

    PubMed

    McElveen, John T; Blackburn, Erin L; Green, J Douglas; McLear, Patrick W; Thimsen, Donald J; Wilson, Blake S

    2010-09-01

    Evaluate the effectiveness of remote programming for cochlear implants. Retrospective review of the cochlear implant performance for patients who had undergone mapping and programming of their cochlear implant via remote connection through the Internet. Postoperative Hearing in Noise Test and Consonant/Nucleus/Consonant word scores for 7 patients who had undergone remote mapping and programming of their cochlear implant were compared with the mean scores of 7 patients who had been programmed by the same audiologist over a 12-month period. Times required for remote and direct programming were also compared. The quality of the Internet connection was assessed using standardized measures. Remote programming was performed via a virtual private network with a separate software program used for video and audio linkage. All 7 patients were programmed successfully via remote connectivity. No untoward patient experiences were encountered. No statistically significant differences could be found in comparing postoperative Hearing in Noise Test and Consonant/Nucleus/Consonant word scores for patients who had undergone remote programming versus a similar group of patients who had their cochlear implant programmed directly. Remote programming did not require a significantly longer programming time for the audiologist with these 7 patients. Remote programming of a cochlear implant can be performed safely without any deterioration in the quality of the programming. This ability to remotely program cochlear implant patients gives the potential to extend cochlear implantation to underserved areas in the United States and elsewhere.

  11. Prevention of Noise Damage to Cochlear Synapses

    DTIC Science & Technology

    2015-10-01

    AWARD NUMBER: W81XWH-14-1-0494 TITLE: Prevention of Noise Damage to Cochlear Synapses PRINCIPAL INVESTIGATOR: Steven Green CONTRACTING...to Cochlear Synapses 5a. CONTRACT NUMBER 5b. GRANT NUMBER W81XWH-14-1-0494 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Steven Green 5d. PROJECT...ABSTRACT Noise-induced synaptopathy is the result of excitotoxic trauma to cochlear synapses due to glutamate released from the hair cells. Excitotoxic

  12. Musical ear syndrome in adult cochlear implant patients.

    PubMed

    Low, W-K; Tham, C A; D'Souza, V-D; Teng, S-W

    2013-09-01

    Except for a single case report, musical ear syndrome in cochlear implantees has not been studied. We aimed to study the prevalence and nature of musical ear syndrome among adult cochlear implant patients, as well as the effect on their emotional well-being. STUDY DESIGN, PATIENTS AND INTERVENTION: A cross-sectional survey of patients aged 18 years and above who had received cochlear implants for profound hearing loss between 1997 and 2010. Of the 82 patients studied, 18 (22 per cent) were found to have experienced musical ear syndrome. Seven and 11 patients had musical ear syndrome prior to and after cochlear implantation, respectively. The character of musical ear syndrome symptoms was described as instrumental music (n = 2), singing (6) or both (10). Fourteen patients reported an adverse emotional effect, with three expressing ‘intolerance’. In this study, 22 per cent of cochlear implantees experienced musical ear syndrome. These symptoms affected patients’ emotional state, but most coped well. Musical ear syndrome can occur prior to and after cochlear implantation.

  13. Cochlear Implants

    MedlinePlus

    ... newsroom@entnet.org . A cochlear implant is an electronic device that restores partial hearing to individuals with ... An internal component that consists of a small electronic device that is surgically implanted under the skin ...

  14. Intraoperative cochlear nerve mapping with the mobile cochlear nerve compound action potential tracer in vestibular schwannoma surgery.

    PubMed

    Watanabe, Nobuyuki; Ishii, Takuya; Fujitsu, Kazuhiko; Kaku, Shogo; Ichikawa, Teruo; Miyahara, Kosuke; Okada, Tomu; Tanino, Shin; Uriu, Yasuhiro; Murayama, Yuichi

    2018-05-18

    OBJECTIVE The authors describe the usefulness and limitations of the cochlear nerve compound action potential (CNAP) mobile tracer (MCT) that they developed to aid in cochlear nerve mapping during vestibular schwannoma surgery (VSS) for hearing preservation. METHODS This MCT device requires no more than 2 seconds for stable placement on the nerve to obtain the CNAP and thus is able to trace the cochlear nerve instantaneously. Simultaneous bipolar and monopolar recording is possible. The authors present the outcomes of 18 consecutive patients who underwent preoperative useful hearing (defined as class I or II of the Gardner-Robertson classification system) and underwent hearing-preservation VSS with the use of the MCT. Mapping was considered successful when it was possible to detect and trace the cochlear nerve. RESULTS Mapping of the cochlear nerve was successful in 13 of 18 patients (72.2%), and useful hearing was preserved in 11 patients (61.1%). Among 8 patients with large tumors (Koos grade 3 or 4), the rate of successful mapping was 62.5% (5 patients). The rate of hearing preservation in patients with large tumors was 50% (4 patients). CONCLUSIONS In addition to microsurgical presumption of the arrangement of each nerve, frequent probing on and around an unidentified nerve and comparison of each waveform are advisable with the use of both more sensitive monopolar and more location-specific bipolar MCT. MCT proved to be useful in cochlear nerve mapping and may consequently be helpful in hearing preservation. The authors discuss some limitations and problems with this device.

  15. Response Properties of Cochlear Nucleus Neurons in Monkeys

    PubMed Central

    Roth, G. Linn; Recio, A.

    2009-01-01

    Much of what is known about how the cochlear nuclei participate in mammalian hearing comes from studies of non-primate mammalian species. To determine to what extent the cochlear nuclei of primates resemble those of other mammalian orders, we have recorded responses to sound in three primate species: marmosets, Cynomolgus macaques, and squirrel monkeys. These recordings show that the same types of temporal firing patterns are found in primates that have been described in other mammals. Responses to tones of neurons in the ventral cochlear nucleus have similar tuning, latencies, post-stimulus time and interspike interval histograms as those recorded in non-primate cochlear nucleus neurons. In the dorsal cochlear nucleus, too, responses were similar. From these results it is evident that insights gained from non-primate studies can be applied to the peripheral auditory system of primates. PMID:19531377

  16. Deafblind People's Experiences of Cochlear Implantation

    ERIC Educational Resources Information Center

    Soper, Janet

    2006-01-01

    Cochlear implants are electronic devices that create the sensation of hearing in those who cannot obtain any benefit from conventional hearing aids. This article examines the experience of cochlear implantation in a select group of individuals with acquired deafblindness, focusing on three key themes: access to communication, information and…

  17. Musical experience sharpens human cochlear tuning.

    PubMed

    Bidelman, Gavin M; Nelms, Caitlin; Bhagat, Shaum P

    2016-05-01

    The mammalian cochlea functions as a filter bank that performs a spectral, Fourier-like decomposition on the acoustic signal. While tuning can be compromised (e.g., broadened with hearing impairment), whether or not human cochlear frequency resolution can be sharpened through experiential factors (e.g., training or learning) has not yet been established. Previous studies have demonstrated sharper psychophysical tuning curves in trained musicians compared to nonmusicians, implying superior peripheral tuning. However, these findings are based on perceptual masking paradigms, and reflect engagement of the entire auditory system rather than cochlear tuning, per se. Here, by directly mapping physiological tuning curves from stimulus frequency otoacoustic emissions (SFOAEs)-cochlear emitted sounds-we show that estimates of human cochlear tuning in a high-frequency cochlear region (4 kHz) is further sharpened (by a factor of 1.5×) in musicians and improves with the number of years of their auditory training. These findings were corroborated by measurements of psychophysical tuning curves (PTCs) derived via simultaneous masking, which similarly showed sharper tuning in musicians. Comparisons between SFOAE and PTCs revealed closer correspondence between physiological and behavioral curves in musicians, indicating that tuning is also more consistent between different levels of auditory processing in trained ears. Our findings demonstrate an experience-dependent enhancement in the resolving power of the cochlear sensory epithelium and the spectral resolution of human hearing and provide a peripheral account for the auditory perceptual benefits observed in musicians. Both local and feedback (e.g., medial olivocochlear efferent) mechanisms are discussed as potential mechanisms for experience-dependent tuning. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. [Cochlear implantation in patients with Waardenburg syndrome type II].

    PubMed

    Wan, Liangcai; Guo, Menghe; Chen, Shuaijun; Liu, Shuangriu; Chen, Hao; Gong, Jian

    2010-05-01

    To describe the multi-channel cochlear implantation in patients with Waardenburg syndrome including surgeries, pre and postoperative hearing assessments as well as outcomes of speech recognition. Multi-channel cochlear implantation surgeries have been performed in 12 cases with Waardenburg syndrome type II in our department from 2000 to 2008. All the patients received multi-channel cochlear implantation through transmastoid facial recess approach. The postoperative outcomes of 12 cases were compared with 12 cases with no inner ear malformation as a control group. The electrodes were totally inserted into the cochlear successfully, there was no facial paralysis and cerebrospinal fluid leakage occurred after operation. The hearing threshold in this series were similar to that of the normal cochlear implantation. After more than half a year of speech rehabilitation, the abilities of speech discrimination and spoken language of all the patients were improved compared with that of preoperation. Multi-channel cochlear implantation could be performed in the cases with Waardenburg syndrome, preoperative hearing and images assessments should be done.

  19. The impact of cochlear fine structure on hearing thresholds and DPOAE levels

    NASA Astrophysics Data System (ADS)

    Lee, Jungmee; Long, Glenis; Talmadge, Carrick L.

    2004-05-01

    Although otoacoustic emissions (OAE) are used as clinical and research tools, the correlation between OAE behavioral estimates of hearing status is not large. In normal-hearing individuals, the level of OAEs can vary as much as 30 dB when the frequency is changed less than 5%. These pseudoperiodic variations of OAE level with frequency are known as fine structure. Hearing thresholds measured with high-frequency resolution reveals a similar (up to 15 dB) fine structure. We examine the impact of OAE and threshold fine structures on the prediction of auditory thresholds from OAE levels. Distortion product otoacoustic emissions (DPOAEs) were measured with sweeping primary tones. Psychoacoustic detection thresholds were measured using pure tones, sweep tones, FM tones, and narrow-band noise. Sweep DPOAE and narrow-band threshold estimates provide estimates that are less influenced by cochlear fine structure and should lead to a higher correlation between OAE levels and psychoacoustic thresholds. [Research supported by PSC CUNY, NIDCD, National Institute on Disability and Rehabilitation Research in U.S. Department of Education, and The Ministry of Education in Korea.

  20. Influence of Bony Defects on Preoperative Shoulder Function in Recurrent Anteroinferior Shoulder Instability.

    PubMed

    Wolke, Julia; Herrmann, Diem Anh; Krannich, Alexander; Scheibel, Markus

    2016-05-01

    Recurrent anteroinferior shoulder dislocations are often associated with bony glenoid and humeral defects. The influence of those bony lesions on the postoperative outcomes after arthroscopic shoulder stabilization procedures has been the subject of many studies. Little is known about the influence of those lesions on preoperative function. To evaluate the influence of glenoid and humeral bony defects on preoperative shoulder function in recurrent anteroinferior shoulder instability. Cross-sectional study; Level of evidence, 3. Included in the study were 90 patients (70 men, 20 women; mean age, 27.1 years; 24 patients with prior failed stabilization) with posttraumatic recurrent anteroinferior shoulder instability who underwent preoperative computed tomography (CT) of both shoulders. The glenoid index was used to measure glenoid defect on a 3-dimensional CT. Humeral head defect was measured on a 2-dimensional CT with evaluation of the Hill-Sachs quotient, product, sum, and difference. Preoperative evaluation also included the Rowe score, Constant score, Walch-Duplay score, Melbourne Instability Shoulder Score (MISS), Western Ontario Shoulder Instability Index (WOSI), and Subjective Shoulder Value (SSV). There was a weak but significant correlation of the Hill-Sachs quotient and the glenoid index with the Rowe score (P = .03, r = -0.22 and P = .03, r = 0.23, respectively). Furthermore, the Hill-Sachs product significantly correlated with the WOSI (P = .02); in particular, the physical symptoms subscore showed a significant correlation (P = .04). The glenoid index showed a significant correlation with the SSV (P < .01). No significant correlation was found between the Walch-Duplay score, Constant score, or MISS and bony defects. The results of this study show that objective and subjective scoring systems correlate significantly with the clinical condition of patients with recurrent shoulder instability and associated bony defects. It is recommended that clinicians

  1. Local cochlear damage reduces local nonlinearity and decreases generator-type cochlear emissions while increasing reflector-type emissions.

    PubMed

    Dong, Wei; Olson, Elizabeth S

    2010-03-01

    Distortion product otoacoustic emissions (DPOAEs) originate in cochlear nonlinearity and emerge into the ear canal as an apparent sum of emission types, one of which (generator) travels directly out and the other (reflector) travels out following linear reflection. The present study explores intracochlear sources of DPOAEs via simultaneous ear canal and intracochlear pressure measurements in gerbils. A locally damaged cochlea was produced with reduced local intracochlear nonlinearity and significant elevation of the compound action potential thresholds at frequencies represented within the damaged region. In the DPOAE the comparison of healthy to locally damaged cochleae showed the following: (1) In the broad frequency region corresponding to the locally damaged best frequency, DPOAEs evoked by wider f(2)/f(1) stimuli decreased, consistent with the reduction in local nonlinearity. (2) DPOAEs evoked by narrow f(2)/f(1) stimuli often had a bimodal change, decreasing in a lower frequency band and increasing in a band just adjacent and higher, and the DPOAE phase-vs-frequency slope steepened. These changes confirm the complex nature of the DPOAE.

  2. [The development of musicality in children after cochlear implantation].

    PubMed

    Zheng, Yan; Liu, Bo; Dong, Ruijuan; Xu, Tianqiu; Chen, Jing; Chen, Xuejing; Zhong, Yan; Meng, Chao; Wang, Hong; Chen, Xueqing

    2014-08-01

    The purpose of this study is to analyze the development of musicality in children after cochlear implantation, and provide a clinical database for the evaluation of their musicality. Twenty-six children with cochlear implants (CI group) participated in this research. They received cochlear implants at the age of 11 to 68 months with a mean of 35.6 months. Seventy-six infants as a control group aged from 1 to 24 months with a mean of 6.1 months participated in this study, whose hearing were considered normal by passing the case history collection, high-risk registers for hearing loss and hearing screening using DPOAE. The music and young children with CIs: Musicality Rating Scale was used to evaluate their musicality. The evaluation was performed before cochlear implantation and 1, 3, 6, 9, 12, 24 months after cochlear implantation for children with cochlear implants. The evaluation was also performed at 1, 3, 6, 9, 12, 24 months for children with normal hearing. The mean scores of musicality showed significant improvements with time of CI use for CI group (P<0.05). The mean scores of musicality also showed significant improvements with time for control group (P<0.05). There were no significant differences in mean scores between CI group and control group at 1, 3, 6, 9, 12 months of hearing age by rank sum test (P>0.05). Significant difference was noted between the two groups at 24 months (P<0.05). The musicality of children with cochlear implants improved significantly with time after cochlear implantation. The most rapid growth was found in the first year after cochlear implantation.

  3. The cochlear CRF signaling systems and their mechanisms of action in modulating cochlear sensitivity and protection against trauma

    PubMed Central

    Graham, Christine E.; Basappa, Johnvesly; Turcan, Sevin; Vetter, Douglas E.

    2011-01-01

    A key requirement for encoding the auditory environment is the ability to dynamically alter cochlear sensitivity. However, merely attaining a steady state of maximal sensitivity is not a viable solution since the sensory cells and ganglion cells of the cochlea are prone to damage following exposure to loud sound. Most often, such damage is via initial metabolic insult that can lead to cellular death. Thus, establishing the highest sensitivity must be balanced with protection against cellular metabolic damage that can lead to loss of hair cells and ganglion cells, resulting in loss of frequency representation. While feedback mechanisms are known to exist in the cochlea that alter sensitivity, they respond only after stimulus encoding, allowing potentially damaging sounds to impact the inner ear at times coincident with increased sensitivity. Thus, questions remain concerning the endogenous signaling systems involved in dynamic modulation of cochlear sensitivity and protection against metabolic stress. Understanding endogenous signaling systems involved in cochlear protection may lead to new strategies and therapies for prevention of cochlear damage and consequent hearing loss. We have recently discovered a novel cochlear signaling system that is molecularly equivalent to the classic hypothalamic-pituitary-adrenal (HPA) axis. This cochlear HPA-equivalent system functions to balance auditory sensitivity and susceptibility to noise-induced hearing loss, and also protects against cellular metabolic insults resulting from exposures to ototoxic drugs. We review the anatomy, physiology, and cellular signaling of this system, and compare it to similar signaling in other organs/tissues of the body. PMID:21909974

  4. Single-unit labeling of medial olivocochlear neurons: the cochlear frequency map for efferent axons.

    PubMed

    Brown, M Christian

    2014-06-01

    Medial olivocochlear (MOC) neurons are efferent neurons that project axons from the brain to the cochlea. Their action on outer hair cells reduces the gain of the "cochlear amplifier," which shifts the dynamic range of hearing and reduces the effects of noise masking. The MOC effects in one ear can be elicited by sound in that ipsilateral ear or by sound in the contralateral ear. To study how MOC neurons project onto the cochlea to mediate these effects, single-unit labeling in guinea pigs was used to study the mapping of MOC neurons for neurons responsive to ipsilateral sound vs. those responsive to contralateral sound. MOC neurons were sharply tuned to sound frequency with a well-defined characteristic frequency (CF). However, their labeled termination spans in the organ of Corti ranged from narrow to broad, innervating between 14 and 69 outer hair cells per axon in a "patchy" pattern. For units responsive to ipsilateral sound, the midpoint of innervation was mapped according to CF in a relationship generally similar to, but with more variability than, that of auditory-nerve fibers. Thus, based on CF mappings, most of the MOC terminations miss outer hair cells involved in the cochlear amplifier for their CF, which are located more basally. Compared with ipsilaterally responsive neurons, contralaterally responsive neurons had an apical offset in termination and a larger span of innervation (an average of 10.41% cochlear distance), suggesting that when contralateral sound activates the MOC reflex, the actions are different than those for ipsilateral sound. Copyright © 2014 the American Physiological Society.

  5. Single-unit labeling of medial olivocochlear neurons: the cochlear frequency map for efferent axons

    PubMed Central

    2014-01-01

    Medial olivocochlear (MOC) neurons are efferent neurons that project axons from the brain to the cochlea. Their action on outer hair cells reduces the gain of the “cochlear amplifier,” which shifts the dynamic range of hearing and reduces the effects of noise masking. The MOC effects in one ear can be elicited by sound in that ipsilateral ear or by sound in the contralateral ear. To study how MOC neurons project onto the cochlea to mediate these effects, single-unit labeling in guinea pigs was used to study the mapping of MOC neurons for neurons responsive to ipsilateral sound vs. those responsive to contralateral sound. MOC neurons were sharply tuned to sound frequency with a well-defined characteristic frequency (CF). However, their labeled termination spans in the organ of Corti ranged from narrow to broad, innervating between 14 and 69 outer hair cells per axon in a “patchy” pattern. For units responsive to ipsilateral sound, the midpoint of innervation was mapped according to CF in a relationship generally similar to, but with more variability than, that of auditory-nerve fibers. Thus, based on CF mappings, most of the MOC terminations miss outer hair cells involved in the cochlear amplifier for their CF, which are located more basally. Compared with ipsilaterally responsive neurons, contralaterally responsive neurons had an apical offset in termination and a larger span of innervation (an average of 10.41% cochlear distance), suggesting that when contralateral sound activates the MOC reflex, the actions are different than those for ipsilateral sound. PMID:24598524

  6. Loudness growth observed under partially tripolar stimulation: model and data from cochlear implant listeners.

    PubMed

    Litvak, Leonid M; Spahr, Anthony J; Emadi, Gulam

    2007-08-01

    Most cochlear implant strategies utilize monopolar stimulation, likely inducing relatively broad activation of the auditory neurons. The spread of activity may be narrowed with a tripolar stimulation scheme, wherein compensating current of opposite polarity is simultaneously delivered to two adjacent electrodes. In this study, a model and cochlear implant subjects were used to examine loudness growth for varying amounts of tripolar compensation, parameterized by a coefficient sigma, ranging from 0 (monopolar) to 1 (full tripolar). In both the model and the subjects, current required for threshold activation could be approximated by I(sigma)=Ithr(0)(1-sigmaK), with fitted constants Ithr(0) and K. Three of the subjects had a "positioner," intended to place their electrode arrays closer to their neural tissue. The values of K were smaller for the positioner users and for a "close" electrode-to-tissue distance in the model. Above threshold, equal-loudness contours for some subjects deviated significantly from a linear scale-up of the threshold approximations. The patterns of deviation were similar to those observed in the model for conditions in which most of the neurons near the center electrode were excited.

  7. Airway Obstruction and the Unilateral Cleft Lip and Palate Deformity: Contributions by the Bony Septum.

    PubMed

    Friel, Michael T; Starbuck, John M; Ghoneima, Ahmed M; Murage, Kariuki; Kula, Katherine S; Tholpady, Sunil; Havlik, Robert J; Flores, Roberto L

    2015-07-01

    Patients with unilateral cleft lip and palate (CLP) deformities commonly develop nasal airway obstruction, necessitating septoplasty at the time of definitive rhinoplasty. We assessed the contribution of the bony septum to airway obstruction using computed tomography (CT) and cone beam CT (CBCT). A 2-year retrospective review of all subjects with unilateral CLP who underwent CBCT imaging (n = 22) and age-matched controls (n = 9) who underwent CT imaging was conducted. Control CT scans were used to determine the segment of nasal septum comprised almost entirely of bone. The CBCT of the nasal airway was assessed using Dolphin software to determine the contribution of the bony septum to septal deviation and airway obstruction. The nasal septum posterior to the midpoint between anterior and posterior nasal spine is comprised of 96% bone. The nasal airway associated with this posterior bony segment was 43.1% (P < 0.001) larger by volume on the non-cleft side in patients with unilateral CLP. The average septal deviation within the posterior bony segment was 5.4 mm, accounting for 74.4% of the maximal deviation within the nasal airway. The average airway stenosis within the posterior bony nasal airway was 0.45 mm (0-2.2 mm). In patients with unilateral CLP, the bony nasal septum can demonstrate significant deviation and airway stenosis. Surgeons should consider a bony septoplasty in their treatment algorithm in unilateral CLP patients who have reached skeletal maturity.

  8. Evaluating cochlear implant trauma to the scala vestibuli.

    PubMed

    Adunka, O; Kiefer, J; Unkelbach, M H; Radeloff, A; Gstoettner, W

    2005-04-01

    Placement of cochlear implant electrodes into the scala vestibuli may be intentional, e.g. in case of blocked scala tympani or unintentional as a result of trauma to the basilar membrane or erroneous location of the cochieostomy. The aim of this study was to evaluate the morphological consequences and cochlear trauma after implantation of different cochlear implant electrode arrays in the scala vestibuli. Human temporal bone study with histological and radiological evaluation. Twelve human cadaver temporal bones were implanted with different cochlear implant electrodes. Implanted bones were processed using a special method to section undecalcified bone. Cochlear trauma and intracochlear positions. All implanted electrodes were implanted into the scala vestibuli using a special approach that allows direct scala vestibuli insertions. Fractures of the osseous spiral lamina were evaluated in some bones in the basal cochlear regions. In most electrodes, delicate structures of the organ of Corti were left intact, however, Reissner's membrane was destroyed in all specimens and the electrode lay upon the tectorial membrane. In some bones the organ of Corti was destroyed. Scala vestibuli insertions did not cause severe trauma to osseous or neural structures, thus preserving the basis for electrostimulation of the cochlea. However, destruction of Reissner's membrane and impact on the Organ of Corti can be assumed to destroy residual hearing.

  9. The influence of cochlear shape on low-frequency hearing.

    PubMed

    Manoussaki, Daphne; Chadwick, Richard S; Ketten, Darlene R; Arruda, Julie; Dimitriadis, Emilios K; O'Malley, Jen T

    2008-04-22

    The conventional theory about the snail shell shape of the mammalian cochlea is that it evolved essentially and perhaps solely to conserve space inside the skull. Recently, a theory proposed that the spiral's graded curvature enhances the cochlea's mechanical response to low frequencies. This article provides a multispecies analysis of cochlear shape to test this theory and demonstrates that the ratio of the radii of curvature from the outermost and innermost turns of the cochlear spiral is a significant cochlear feature that correlates strongly with low-frequency hearing limits. The ratio, which is a measure of curvature gradient, is a reflection of the ability of cochlear curvature to focus acoustic energy at the outer wall of the cochlear canal as the wave propagates toward the apex of the cochlea.

  10. Cochlear implants in children implanted in Jordan: A parental overview.

    PubMed

    Alkhamra, Rana A

    2015-07-01

    Exploring the perspective of parents on the cochlear implant process in Jordan. Sixty parents of deaf children were surveyed on the information gathering process prior to cochlear implant surgery, and their implant outcome expectations post-surgery. Whether child or parent characteristics may impact parents' post-surgical expectations was explored. Although parents used a variety of information sources when considering a cochlear implant, the ear, nose and throat doctor comprised their major source of information (60%). Parents received a range of information prior to cochlear implant but agreed (93.3%) on the need for a multidisciplinary team approach. Post-surgically, parents' expected major developments in the areas of spoken language (97%), and auditory skills (100%). Receiving education in mainstream schools (92%) was expected too. Parents perceived the cochlear implant decision as the best decision they can make for their child (98.3%). A significant correlation was found between parents contentment with the cochlear implant decision and expecting developments in the area of reading and writing (r=0.7). Child's age at implantation and age at hearing loss diagnosis significantly affected parents' post-implant outcome expectations (p<0.05). Despite the general satisfaction from the information quantity and quality prior to cochlear implant, parents agree on the need for a comprehensive multidisciplinary team approach during the different stages of the cochlear implant process. Parents' education about cochlear implants prior to the surgery can affect their post-surgical outcome expectations. The parental perspective presented in this study can help professionals develop better understanding of parents' needs and expectations and henceforth improve their services and support during the different stages of the cochlear implant process. Copyright © 2015. Published by Elsevier Ireland Ltd.

  11. Mammalian spontaneous otoacoustic emissions are amplitude-stabilized cochlear standing waves.

    PubMed

    Shera, Christopher A

    2003-07-01

    Mammalian spontaneous otoacoustic emissions (SOAEs) have been suggested to arise by three different mechanisms. The local-oscillator model, dating back to the work of Thomas Gold, supposes that SOAEs arise through the local, autonomous oscillation of some cellular constituent of the organ of Corti (e.g., the "active process" underlying the cochlear amplifier). Two other models, by contrast, both suppose that SOAEs are a global collective phenomenon--cochlear standing waves created by multiple internal reflection--but differ on the nature of the proposed power source: Whereas the "passive" standing-wave model supposes that SOAEs are biological noise, passively amplified by cochlear standing-wave resonances acting as narrow-band nonlinear filters, the "active" standing-wave model supposes that standing-wave amplitudes are actively maintained by coherent wave amplification within the cochlea. Quantitative tests of key predictions that distinguish the local-oscillator and global standing-wave models are presented and shown to support the global standing-wave model. In addition to predicting the existence of multiple emissions with a characteristic minimum frequency spacing, the global standing-wave model accurately predicts the mean value of this spacing, its standard deviation, and its power-law dependence on SOAE frequency. Furthermore, the global standing-wave model accounts for the magnitude, sign, and frequency dependence of changes in SOAE frequency that result from modulations in middle-ear stiffness. Although some of these SOAE characteristics may be replicable through artful ad hoc adjustment of local-oscillator models, they all arise quite naturally in the standing-wave framework. Finally, the statistics of SOAE time waveforms demonstrate that SOAEs are coherent, amplitude-stabilized signals, as predicted by the active standing-wave model. Taken together, the results imply that SOAEs are amplitude-stabilized standing waves produced by the cochlea acting as a

  12. Electric charge requirements of pediatric cochlear implant recipients enrolled in the Childhood Development After Cochlear Implantation study.

    PubMed

    Zwolan, Teresa A; O'Sullivan, Mary Beth; Fink, Nancy E; Niparko, John K

    2008-02-01

    To evaluate mapping characteristics of children with cochlear implants who are enrolled in the Childhood Development After Cochlear Implantation (CDACI) multicenter study. Longitudinal evaluation during 24 months of speech processor maps of children with cochlear implants prospectively enrolled in the study. Six tertiary referral centers. One hundred eighty-eight children enrolled in the CDACI study who were 5 years old or younger at the time of enrollment. Of these children, 184 received unilateral implants, and 4 received simultaneous bilateral implants. Children attended regular mapping sessions at their implant clinic as part of the study protocol. Maps were examined for each subject at 4 different time intervals: at device activation and 6, 12, and 24 months postactivation. Mean C/M levels (in charge per phase) were compared for 4 different time intervals, for 3 different devices, for 6 different implant centers, and for children with normal and abnormal cochleae. All 3 types of implant devices demonstrate significant increases in C/M levels between device activation and the 24-month appointment. Significant differences in mean C/M levels were noted between devices. Children with cochlear anomalies demonstrate significantly greater C/M levels than children with normal cochleae. The CDACI study has enabled us to evaluate the mapping characteristics of pediatric patients who use 3 different devices and were implanted at a variety of implant centers. Analysis of such data enables us to better understand the mapping characteristics of children with cochlear implants.

  13. The cochlear implant as a tinnitus treatment.

    PubMed

    Vallés-Varela, Héctor; Royo-López, Juan; Carmen-Sampériz, Luis; Sebastián-Cortés, José M; Alfonso-Collado, Ignacio

    2013-01-01

    Tinnitus is a symptom of high prevalence in patients with cochlear pathology. We studied the evolution of tinnitus in patients undergoing unilateral cochlear implantation for treatment of profound hearing loss. This was a longitudinal, retrospective study of patients that underwent unilateral cochlear implantation and who had bilateral tinnitus. Tinnitus was assessed quantitatively and qualitatively before surgery and at 6 and 12 months after surgery. We evaluated 20 patients that underwent unilateral cochlear implantation with a Nucleus(®) CI24RE Contour Advance™ electrode device. During the periods in which the device was in operation, improvement or disappearance of tinnitus was evidenced in the ipsilateral ear in 65% of patients, and in the contralateral ear, in 50%. In periods in which the device was disconnected, improvement or disappearance of tinnitus was found in the ipsilateral ear in 50% of patients, and in the ear contralateral to the implant in 45% of the patients. In 10% of the patients, a new tinnitus appeared in the ipsilateral ear. The patients with profound hearing loss and bilateral tinnitus treated with unilateral cochlear implantation improved in a high percentage of cases, in the ipsilateral ear and in the contralateral ear. Copyright © 2012 Elsevier España, S.L. All rights reserved.

  14. Treatment of oroantral fistulas using bony press-fit technique.

    PubMed

    Er, Nuray; Tuncer, Hakan Yusuf; Karaca, Ciğdem; Copuroğlu, Seçil

    2013-04-01

    The objective of this study was to determine the effectiveness of the bony press-fit technique in closing oroantral communications (OACs) and oroantral fistulas (OAFs) and in identifying potential intraoral donor sites. Ten patients, 4 with OACs and 6 with OAFs, were treated with autogenous bone grafts using the bony press-fit technique. In 9 patients, dental extractions caused OACs or OAFs; in 1 patient, an OAC appeared after cyst enucleation. Donor sites included the chin (3 patients), buccal exostosis (1 patient), maxillary tuberosity (2 patients), ramus (1 patient), and the lateral wall of the maxillary sinus (3 patients). The preoperative evaluation of the patients, surgical technique, and postoperative management were examined. In all 10 patients, a stable press fit of the graft was achieved. Additional fixation methods were not needed. In 2 patients, mucosal dehiscence developed, but healed spontaneously. In 2 patients, dental implant surgery was performed in the grafted area. Treatment of 10 patients with OACs or OAFs was performed, with a 100% success rate. The bony press-fit technique can be used to safely close OACs or OAFs, and it presents some advantages compared with other techniques. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  15. A global patient outcomes registry: Cochlear paediatric implanted recipient observational study (Cochlear(™) P-IROS).

    PubMed

    Sanderson, Georgina; Ariyaratne, Thathya V; Wyss, Josephine; Looi, Valerie

    2014-01-01

    Currently, there is a paucity of data concerning the long-term outcomes, educational placement and quality of life of children implanted with hearing devices from large and representative samples of the population. To address this concern, a large, prospective, multicentre, multinational patient-outcomes registry for paediatric recipients of implantable hearing devices was developed. The benefits of this registry, its approach and methodology are described. The Cochlear(™) Paediatric Implanted Recipient Observational Study (Cochlear P-IROS) is a prospective international patient-outcomes registry for children who are implanted in routine clinical practice with one or more hearing devices. The study aims to collect data on patient comorbidities, device use, auditory performance, quality of life and health-related utilities, across different types of implantable hearing devices from a range of manufacturers. Patients will be evaluated with a set of standardised and non-standardised questionnaires prior to initial device activation (baseline) and at six-monthly follow-up intervals up to 24 months and annually thereafter. The Cochlear P-IROS utilises a secure web interface to administer electronic case report forms to clinicians and families of implanted children. The web interface is currently available in five languages: English, Japanese, Korean, Mandarin and Russian. The interface also provides printable versions of the case report forms translated into 22 local languages for collection of data prior to entry online; additional languages may be added, as required. Participation in the Cochlear P-IROS registry is investigator-driven and voluntary. To date, the Cochlear P-IROS has recruited implant clinics across Australia, China, India, Indonesia, Turkey and Vietnam. The registry also aims to recruit multiple clinics in Cuba, Israel, Japan, Malaysia, Singapore, South Africa, South Korea and Russia. The use of a registry such as the Cochlear P-IROS will generate

  16. Animal model of cochlear third window in the scala vestibuli or scala tympani.

    PubMed

    Attias, Joseph; Preis, Michal; Shemesh, Rafi; Hadar, Tuvia; Nageris, Ben I

    2010-08-01

    The auditory impact of a cochlear third window differs by its location in the scala vestibuli or scala tympani. Pathologic third window has been investigated primarily in the vestibular apparatus of animals and humans. Dehiscence of the superior semicircular canal is the clinical model. Fat sand rats (n = 11) have a unique inner-ear anatomy that allows easy surgical access. A window was drilled in the bony labyrinth over the scala vestibuli in 1 group (12 ears) and over the scala tympani in another (7 ears) while preserving the membranous labyrinth. Auditory brain stem responses to high- and low-frequency stimuli delivered by air and bone conduction were recorded before and after the procedure. Scala vestibuli group: preoperative air-conduction thresholds to clicks and tone-bursts averaged 8.3 and 9.6 dB, respectively, and bone-conduction thresholds, 4.6 and 3.3 dB, respectively; after fenestration, air-conduction thresholds averaged 40.4 and 41.8 dB, respectively, and bone-conduction thresholds, -1 and 5.6 dB, respectively. Scala tympani group: preoperative air-conduction thresholds to clicks and tone-bursts averaged 8.6 dB each, and bone-conduction thresholds, 7.9 dB and 7.1 dB, respectively; after fenestration, air-conduction thresholds averaged 11.4 and 9.3 dB, respectively, and bone-conduction thresholds, 9.3 and 4.2 dB, respectively. The changes in air- (p = 0.0001) and bone-conduction (p = 0.04) thresholds were statistically significant only in the scala vestibuli group. The presence of a cochlear third window over the scala vestibuli, but not over the scala tympani, causes a significant increase in air-conduction auditory thresholds. These results agree with the theoretic model and clinical findings and contribute to our understanding of vestibular dehiscence.

  17. Bony morphology of the hip in professional ballet dancers compared to athletes.

    PubMed

    Mayes, Susan; Ferris, April-Rose; Smith, Peter; Garnham, Andrew; Cook, Jill

    2017-07-01

    To compare hip bony morphology between ballet dancers and a sporting control group and to determine the relationship with hip pain. Thirty-three professional ballet dancers and 33 age- and sex-matched athletes completed questionnaires, including the Copenhagen Hip and Groin Outcome Score (HAGOS), and underwent clinical testing and 3.0-T magnetic resonance imaging to measure acetabular coverage with lateral centre edge angles, femoral head-neck junction concavity with alpha angles at anterior and superior positions, femoral neck-shaft angles, and acetabular version angles. Bony morphological measures fell within normal ranges. Dancers had higher neck-shaft angles (dancers 134.6 ± 4.6°/athletes130.8 ± 4.7°, p = 0.002), lower acetabular version angles (13.5 ± 4.7°/17.1 ± 4.7°, p = 0.003), lower superior alpha angles (38.9 ± 6.9°/46.7 ± 10.6°, p < 0.001), similar anterior alpha angles (43.6 ± 8.1/46 ± 7°, p = 0.2), and similar lateral centre edge angles (28.8 ± 4.6°/30.8 ± 4.5°, p = 0.07) compared to athletes. Abnormal morphology was detected in dancers: 3% acetabular dysplasia (athletes 0), 15% borderline dysplasia (6%), 24% cam morphology (33%), 24% coxa valga (6%), and 21% acetabular retroversion (18%). The HAGOS pain scores correlated moderately with acetabular version (r = -0.43, p = 0.02) in dancers, with no other correlation between pain and morphological parameters in either group. Professional ballet dancers have hip bony morphology that differentiates them from athletes. Hip pain correlated poorly with bony morphology. • Ballet dancers have hip bony morphology that may allow extreme hip motion. • Morphological parameter means fell within normal reference intervals in dancers. • Bony morphology correlates poorly with hip pain. • The risk of hip injury due to abnormal morphology requires prospective studies.

  18. Blunt chest trauma: bony injury in the thorax.

    PubMed

    Zreik, Nasri H; Francis, Irene; Ray, Arun; Rogers, Benedict A; Ricketts, David M

    2016-02-01

    The management of blunt chest trauma is an evolving concept with no clear current guidelines. This article explores the bony injuries associated with this, focusing on rib fractures and flail segments and the themes around investigation and best management.

  19. [Inspecting the cochlear scala tympanic with flexible and semi-flexible micro-endoscope].

    PubMed

    Zhang, Daoxcing; Zhang, Yankun

    2006-02-01

    Flexible and semi-flexible micro-endoscopes were used in cochlear scala tympani inspection , to explore their application in inner ear examination. Fifteen profound hearing loss patients preparing for cochlear implant were included in this study. During the operation, micro-endoscopy was performed after opening the cochlear scala tympani. And 1 mm diameter semi-flexible micro-endoscope could go as deep as 9 mm into the cochlear scala tympani, while 0. 5 mm diameter flexible micro-endoscope could go as deep as 25 mm. The inspecting results were compared with video recording. Using 0.5 mm flexible micro-endoscope, we canould check cochlear scala tympani with depth range of 15-25 mm, but the video imaging was not clear enough to examine the microstructure in the cochlear. With 1 mm diameter semi-flexible micro-endoscope, we could reach 9 mm deep into the cochlear. During the examination, we found 3 cases with calcification deposit in osseous spiral lamina, l case with granulation tissue in the lateral wall of scala tympani, no abnormal findings in the other 11 cases. Inspecting the cochlear scala tympani with 0.5 mm flexible micro-endoscope, even though we can reach the second circuit of the cochlear, it is difficult to find the pathology in the cochlear because of the poor video imaging. With 1 mm semi-flexible micro-endoscope, we can identify the microstructure of the cochlear clearly and find the pathologic changes, but the inserting depth was limited to 9 mm with limitation to examine the whole cochlear.

  20. Music mixing preferences of cochlear implant recipients: a pilot study.

    PubMed

    Buyens, Wim; van Dijk, Bas; Moonen, Marc; Wouters, Jan

    2014-05-01

    Music perception and appraisal are generally poor in cochlear implant recipients. Simple musical structures, lyrics that are easy to follow, and clear rhythm/beat have been reported among the top factors to enhance music enjoyment. The present study investigated the preference for modified relative instrument levels in music with normal-hearing and cochlear implant subjects. In experiment 1, test subjects were given a mixing console and multi-track recordings to determine their most enjoyable audio mix. In experiment 2, a preference rating experiment based on the preferred relative level settings in experiment 1 was performed. Experiment 1 was performed with four postlingually deafened cochlear implant subjects, experiment 2 with ten normal-hearing and ten cochlear implant subjects. A significant difference in preference rating was found between normal-hearing and cochlear implant subjects. The latter preferred an audio mix with larger vocals-to-instruments ratio. In addition, given an audio mix with clear vocals and attenuated instruments, cochlear implant subjects preferred the bass/drum track to be louder than the other instrument tracks. The original audio mix in real-world music might not be suitable for cochlear implant recipients. Modifying the relative instrument level settings potentially improves music enjoyment.

  1. Cochlear Implantation after Bilateral Transverse Temporal Bone Fractures

    PubMed Central

    Shin, Jong-Heon; Park, SooChan; Baek, Sam-Hyun

    2008-01-01

    Patients deafened by a severe head injury are rarely encountered. We report a case of a 65-yr-old man with bilateral transverse temporal bone fractures due to head injury. He underwent cochlear implant and achieved a satisfactory auditory rehabilitation. Imaging studies of temporal bone before performing a cochlear implantation provide important information on a patient with bilateral temporal bone fractures. Cochlear implantations with careful planning in such a patient may be a very effective method for aural rehabilitation. PMID:19434252

  2. Tinnitus after Simultaneous and Sequential Bilateral Cochlear Implantation.

    PubMed

    Ramakers, Geerte G J; Kraaijenga, Véronique J C; Smulders, Yvette E; van Zon, Alice; Stegeman, Inge; Stokroos, Robert J; Free, Rolien H; Frijns, Johan H M; Huinck, Wendy J; Van Zanten, Gijsbert A; Grolman, Wilko

    2017-01-01

    There is an ongoing global discussion on whether or not bilateral cochlear implantation should be standard care for bilateral deafness. Contrary to unilateral cochlear implantation, however, little is known about the effect of bilateral cochlear implantation on tinnitus. To investigate tinnitus outcomes 1 year after bilateral cochlear implantation. Secondarily, to compare tinnitus outcomes between simultaneous and sequential bilateral cochlear implantation and to investigate long-term follow-up (3 years). This study is a secondary analysis as part of a multicenter randomized controlled trial. Thirty-eight postlingually deafened adults were included in the original trial, in which the presence of tinnitus was not an inclusion criterion. All participants received cochlear implants (CIs) because of profound hearing loss. Nineteen participants received bilateral CIs simultaneously and 19 participants received bilateral CIs sequentially with an inter-implant interval of 2 years. The prevalence and severity of tinnitus before and after simultaneous and sequential bilateral cochlear implantation were measured preoperatively and each year after implantation with the Tinnitus Handicap Inventory (THI) and Tinnitus Questionnaire (TQ). The prevalence of preoperative tinnitus was 42% (16/38). One year after bilateral implantation, there was a median difference of -8 (inter-quartile range (IQR): -28 to 4) in THI score and -9 (IQR: -17 to -9) in TQ score in the participants with preoperative tinnitus. Induction of tinnitus occurred in five participants, all in the simultaneous group, in the year after bilateral implantation. Although the preoperative and also the postoperative median THI and TQ scores were higher in the simultaneous group, the median difference scores were equal in both groups. In the simultaneous group, tinnitus scores fluctuated in the 3 years after implantation. In the sequential group, four patients had an additional benefit of the second CI: a total

  3. The development of the Nucleus Freedom Cochlear implant system.

    PubMed

    Patrick, James F; Busby, Peter A; Gibson, Peter J

    2006-12-01

    Cochlear Limited (Cochlear) released the fourth-generation cochlear implant system, Nucleus Freedom, in 2005. Freedom is based on 25 years of experience in cochlear implant research and development and incorporates advances in medicine, implantable materials, electronic technology, and sound coding. This article presents the development of Cochlear's implant systems, with an overview of the first 3 generations, and details of the Freedom system: the CI24RE receiver-stimulator, the Contour Advance electrode, the modular Freedom processor, the available speech coding strategies, the input processing options of Smart Sound to improve the signal before coding as electrical signals, and the programming software. Preliminary results from multicenter studies with the Freedom system are reported, demonstrating better levels of performance compared with the previous systems. The final section presents the most recent implant reliability data, with the early findings at 18 months showing improved reliability of the Freedom implant compared with the earlier Nucleus 3 System. Also reported are some of the findings of Cochlear's collaborative research programs to improve recipient outcomes. Included are studies showing the benefits from bilateral implants, electroacoustic stimulation using an ipsilateral and/or contralateral hearing aid, advanced speech coding, and streamlined speech processor programming.

  4. The Hearing Outcomes of Cochlear Implantation in Waardenburg Syndrome.

    PubMed

    Koyama, Hajime; Kashio, Akinori; Sakata, Aki; Tsutsumiuchi, Katsuhiro; Matsumoto, Yu; Karino, Shotaro; Kakigi, Akinobu; Iwasaki, Shinichi; Yamasoba, Tatsuya

    2016-01-01

    Objectives. This study aimed to determine the feasibility of cochlear implantation for sensorineural hearing loss in patients with Waardenburg syndrome. Method. A retrospective chart review was performed on patients who underwent cochlear implantation at the University of Tokyo Hospital. Clinical classification, genetic mutation, clinical course, preoperative hearing threshold, high-resolution computed tomography of the temporal bone, and postoperative hearing outcome were assessed. Result. Five children with Waardenburg syndrome underwent cochlear implantation. The average age at implantation was 2 years 11 months (ranging from 1 year 9 months to 6 years 3 months). Four patients had congenital profound hearing loss and one patient had progressive hearing loss. Two patients had an inner ear malformation of cochlear incomplete partition type 2. No surgical complication or difficulty was seen in any patient. All patients showed good hearing outcome postoperatively. Conclusion. Cochlear implantation could be a good treatment option for Waardenburg syndrome.

  5. The Hearing Outcomes of Cochlear Implantation in Waardenburg Syndrome

    PubMed Central

    Koyama, Hajime; Kashio, Akinori; Sakata, Aki; Tsutsumiuchi, Katsuhiro; Matsumoto, Yu; Karino, Shotaro; Kakigi, Akinobu; Iwasaki, Shinichi; Yamasoba, Tatsuya

    2016-01-01

    Objectives. This study aimed to determine the feasibility of cochlear implantation for sensorineural hearing loss in patients with Waardenburg syndrome. Method. A retrospective chart review was performed on patients who underwent cochlear implantation at the University of Tokyo Hospital. Clinical classification, genetic mutation, clinical course, preoperative hearing threshold, high-resolution computed tomography of the temporal bone, and postoperative hearing outcome were assessed. Result. Five children with Waardenburg syndrome underwent cochlear implantation. The average age at implantation was 2 years 11 months (ranging from 1 year 9 months to 6 years 3 months). Four patients had congenital profound hearing loss and one patient had progressive hearing loss. Two patients had an inner ear malformation of cochlear incomplete partition type 2. No surgical complication or difficulty was seen in any patient. All patients showed good hearing outcome postoperatively. Conclusion. Cochlear implantation could be a good treatment option for Waardenburg syndrome. PMID:27376080

  6. Radiographic detection of artificial intra-bony defects in the edentulous area.

    PubMed

    Van Assche, N; Jacobs, R; Coucke, W; van Steenberghe, D; Quirynen, M

    2009-03-01

    Since intra-bony pathologies might jeopardize implant outcome, their preoperative detection is crucial. In sixteen human cadaver bloc sections from upper and lower jaws, artificial defects with progressively increasing size (n=7) have been created. From each respective defect, analogue and digital intra-oral radiographs were taken, the latter processed via a periodontal filter and afterwards presented in black-white as well as in colour, resulting in three sets of 7 images per bloc section. Eight observers were asked to diagnosis an eventual defect on randomly presented radiographs, and at another occasion to rank each set based on the defect size. The clinicians were only able to identify a defect, when the junctional area was involved, except for bony pieces with a very homogeneous structure. For longitudinal evaluation of healing bone (e.g. after tooth extraction), colour digital images can be recommended. These observations indicate that intra-oral radiographs are not always reliable for the detection of any intra-bony defect.

  7. Use of suprathreshold stochastic resonance in cochlear implant coding

    NASA Astrophysics Data System (ADS)

    Allingham, David; Stocks, Nigel G.; Morse, Robert P.

    2003-05-01

    In this article we discuss the possible use of a novel form of stochastic resonance, termed suprathreshold stochastic resonance (SSR), to improve signal encoding/transmission in cochlear implants. A model, based on the leaky-integrate-and-fire (LIF) neuron, has been developed from physiological data and use to model information flow in a population of cochlear nerve fibers. It is demonstrated that information flow can, in principle, be enhanced by the SSR effect. Furthermore, SSR was found to enhance information transmission for signal parameters that are commonly encountered in cochlear implants. This, therefore, gives hope that SSR may be implemented in cochlear implants to improve speech comprehension.

  8. In vivo imaging of mammalian cochlear blood flow using fluorescence microendoscopy.

    PubMed

    Monfared, Ashkan; Blevins, Nikolas H; Cheung, Eunice L M; Jung, Juergen C; Popelka, Gerald; Schnitzer, Mark J

    2006-02-01

    We sought to develop techniques for visualizing cochlear blood flow in live mammalian subjects using fluorescence microendoscopy. Inner ear microcirculation appears to be intimately involved in cochlear function. Blood velocity measurements suggest that intense sounds can alter cochlear blood flow. Disruption of cochlear blood flow may be a significant cause of hearing impairment, including sudden sensorineural hearing loss. However, inability to image cochlear blood flow in a nondestructive manner has limited investigation of the role of inner ear microcirculation in hearing function. Present techniques for imaging cochlear microcirculation using intravital light microscopy involve extensive perturbations to cochlear structure, precluding application in human patients. The few previous endoscopy studies of the cochlea have suffered from optical resolution insufficient for visualizing cochlear microvasculature. Fluorescence microendoscopy is an emerging minimally invasive imaging modality that provides micron-scale resolution in tissues inaccessible to light microscopy. In this article, we describe the use of fluorescence microendoscopy in live guinea pigs to image capillary blood flow and movements of individual red blood cells within the basal turn of the cochlea. We anesthetized eight adult guinea pigs and accessed the inner ear through the mastoid bulla. After intravenous injection of fluorescein dye, we made a limited cochleostomy and introduced a compound doublet gradient refractive index endoscope probe 1 mm in diameter into the inner ear. We then imaged cochlear blood flow within individual vessels in an epifluorescence configuration using one-photon fluorescence microendoscopy. We observed single red blood cells passing through individual capillaries in several cochlear structures, including the round window membrane, spiral ligament, osseous spiral lamina, and basilar membrane. Blood flow velocities within inner ear capillaries varied widely, with

  9. Outcomes of cochlear implantation in deaf children of deaf parents: comparative study.

    PubMed

    Hassanzadeh, S

    2012-10-01

    This retrospective study compared the cochlear implantation outcomes of first- and second-generation deaf children. The study group consisted of seven deaf, cochlear-implanted children with deaf parents. An equal number of deaf children with normal-hearing parents were selected by matched sampling as a reference group. Participants were matched based on onset and severity of deafness, duration of deafness, age at cochlear implantation, duration of cochlear implantation, gender, and cochlear implant model. We used the Persian Auditory Perception Test for the Hearing Impaired, the Speech Intelligibility Rating scale, and the Sentence Imitation Test, in order to measure participants' speech perception, speech production and language development, respectively. Both groups of children showed auditory and speech development. However, the second-generation deaf children (i.e. deaf children of deaf parents) exceeded the cochlear implantation performance of the deaf children with hearing parents. This study confirms that second-generation deaf children exceed deaf children of hearing parents in terms of cochlear implantation performance. Encouraging deaf children to communicate in sign language from a very early age, before cochlear implantation, appears to improve their ability to learn spoken language after cochlear implantation.

  10. Prevention and management of cochlear implant infections.

    PubMed

    Gluth, Michael B; Singh, Rajesh; Atlas, Marcus D

    2011-11-01

    Understanding the issues of infection related to an implantable medical device is crucial to all cochlear implant teams. Furthermore, given the risk of central nervous system complications and the relatively high quantity of underlying resource investment associated with cochlear implantation, the stakes of infection are high. The optimal strategies to prevent and manage such infections are still evolving as good-quality prospective data to guide such management decisions are not yet abundant within the medical literature and many recommendations are based on retrospective reviews or anecdotal evidence. We will outline a general strategy to deal with cochlear implant-related infection based on both the authors' experience and the published literature.

  11. Gain and frequency tuning within the mouse cochlear apex

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oghalai, John S.; Raphael, Patrick D.; Gao, Simon

    Normal mammalian hearing requires cochlear outer hair cell active processes that amplify the traveling wave with high gain and sharp tuning, termed cochlear amplification. We have used optical coherence tomography to study cochlear amplification within the apical turn of the mouse cochlea. We measured not only classical basilar membrane vibratory tuning curves but also vibratory responses from the rest of the tissues that compose the organ of Corti. Basilar membrane tuning was sharp in live mice and broad in dead mice, whereas other regions of the organ of Corti demonstrated phase shifts consistent with additional filtering beyond that provided bymore » basilar membrane mechanics. We use these experimental data to support a conceptual framework of how cochlear amplification is tuned within the mouse cochlear apex. We will also study transgenic mice with targeted mutations that affect different biomechanical aspects of the organ of Corti in an effort to localize the underlying processes that produce this additional filtering.« less

  12. [Emotional response to music by postlingually-deafened adult cochlear implant users].

    PubMed

    Wang, Shuo; Dong, Ruijuan; Zhou, Yun; Li, Jing; Qi, Beier; Liu, Bo

    2012-10-01

    To assess the emotional response to music by postlingually-deafened adult cochlear implant users. Munich music questionnaire (MUMU) was used to match the music experience and the motivation of use of music between 12 normal-hearing and 12 cochlear implant subjects. Emotion rating test in Musical Sounds in Cochlear Implants (MuSIC) test battery was used to assess the emotion perception ability for both normal-hearing and cochlear implant subjects. A total of 15 pieces of music phases were used. Responses were given by selecting the rating scales from 1 to 10. "1" represents "very sad" feeling, and "10" represents "very happy feeling. In comparison with normal-hearing subjects, 12 cochlear implant subjects made less active use of music for emotional purpose. The emotion ratings for cochlear implant subjects were similar to normal-hearing subjects, but with large variability. Post-lingually deafened cochlear implant subjects on average performed similarly in emotion rating tasks relative to normal-hearing subjects, but their active use of music for emotional purpose was obviously less than normal-hearing subjects.

  13. Skull base bony lesions: Management nuances; a retrospective analysis from a Tertiary Care Centre

    PubMed Central

    Singh, Amit Kumar; Srivastava, Arun Kumar; Sardhara, Jayesh; Bhaisora, Kamlesh Singh; Das, Kuntal Kanti; Mehrotra, Anant; Sahu, Rabi Narayan; Jaiswal, Awadhesh Kumar; Behari, Sanjay

    2017-01-01

    Background: Skull base lesions are not uncommon, but their management has been challenging for surgeons. There is large no of bony tumors at the skull base which has not been studied in detail as a group. These tumors are difficult not only because of their location but also due to their variability in the involvement of important local structure. Through this retrospective analysis from a Tertiary Care Centre, we are summarizing the details of skull base bony lesions and its management nuances. Materials and Methods: The histopathologically, radiologically, and surgically proven cases of skull base bony tumors or lesions involving bone were analyzed from the neurosurgery, neuropathology record of our Tertiary Care Institute from January 2009 to January 2014. All available preoperative and postoperative details were noted from their case files. The extent of excision was ascertained from operation records and postoperative magnetic resonance imaging if available. Results: We have surgically managed 41 cases of skull base bony tumors. It includes 11 patients of anterior skull base, 13 middle skull base, and 17 posterior skull base bony tumors. The most common bony tumor was chordoma 15 (36.6%), followed by fibrous dysplasia 5 (12.2%), chondrosarcoma (12.2%), and ewings sarcoma-peripheral primitive neuroectodermal tumor (EWS-pPNET) five cases (12.2%) each. There were more malignant lesions (n = 29, 70.7%) at skull base than benign (n = 12, 29.3%) lesions. The surgical approach employed depended on location of tumor and pathology. Total mortality was 8 (20%) of whom 5 patients were of histological proven EWS-pPNET. Conclusions: Bony skull base lesion consists of wide variety of lesions, and requires multispecialty management. The complex lesions required tailored approaches surgery of these lesions. With the advent of microsurgical and endoscopic techniques, and use of navigation better outcomes are being seen, but these lesions require further study for development

  14. Quantitative polarized light microscopy of unstained mammalian cochlear sections

    NASA Astrophysics Data System (ADS)

    Kalwani, Neil M.; Ong, Cheng Ai; Lysaght, Andrew C.; Haward, Simon J.; McKinley, Gareth H.; Stankovic, Konstantina M.

    2013-02-01

    Hearing loss is the most common sensory deficit in the world, and most frequently it originates in the inner ear. Yet, the inner ear has been difficult to access for diagnosis because of its small size, delicate nature, complex three-dimensional anatomy, and encasement in the densest bone in the body. Evolving optical methods are promising to afford cellular diagnosis of pathologic changes in the inner ear. To appropriately interpret results from these emerging technologies, it is important to characterize optical properties of cochlear tissues. Here, we focus on that characterization using quantitative polarized light microscopy (qPLM) applied to unstained cochlear sections of the mouse, a common animal model of human hearing loss. We find that the most birefringent cochlear materials are collagen fibrils and myelin. Retardance of the otic capsule, the spiral ligament, and the basilar membrane are substantially higher than that of other cochlear structures. Retardance of the spiral ligament and the basilar membrane decrease from the cochlear base to the apex, compared with the more uniform retardance of other structures. The intricate structural details revealed by qPLM of unstained cochlear sections ex vivo strongly motivate future application of polarization-sensitive optical coherence tomography to human cochlea in vivo.

  15. Quantitative polarized light microscopy of unstained mammalian cochlear sections

    PubMed Central

    Kalwani, Neil M.; Ong, Cheng Ai; Lysaght, Andrew C.; Haward, Simon J.; McKinley, Gareth H.

    2013-01-01

    Abstract. Hearing loss is the most common sensory deficit in the world, and most frequently it originates in the inner ear. Yet, the inner ear has been difficult to access for diagnosis because of its small size, delicate nature, complex three-dimensional anatomy, and encasement in the densest bone in the body. Evolving optical methods are promising to afford cellular diagnosis of pathologic changes in the inner ear. To appropriately interpret results from these emerging technologies, it is important to characterize optical properties of cochlear tissues. Here, we focus on that characterization using quantitative polarized light microscopy (qPLM) applied to unstained cochlear sections of the mouse, a common animal model of human hearing loss. We find that the most birefringent cochlear materials are collagen fibrils and myelin. Retardance of the otic capsule, the spiral ligament, and the basilar membrane are substantially higher than that of other cochlear structures. Retardance of the spiral ligament and the basilar membrane decrease from the cochlear base to the apex, compared with the more uniform retardance of other structures. The intricate structural details revealed by qPLM of unstained cochlear sections ex vivo strongly motivate future application of polarization-sensitive optical coherence tomography to human cochlea in vivo. PMID:23407909

  16. United Kingdom national paediatric bilateral cochlear implant audit: preliminary results.

    PubMed

    Cullington, Helen; Bele, Devyanee; Brinton, Julie; Lutman, Mark

    2013-11-01

    Prior to 2009, United Kingdom (UK) public funding was mainly only available for children to receive unilateral cochlear implants. In 2009, the National Institute for Health and Care Excellence published guidance for cochlear implantation following their review. According to these guidelines, all suitable children are eligible to have simultaneous bilateral cochlear implants or a sequential bilateral cochlear implant if they had received the first before the guidelines were published. Fifteen UK cochlear implant centres formed a consortium to carry out a multi-centre audit. The audit involves collecting data from simultaneously and sequentially implanted children at four intervals: before bilateral cochlear implants or before the sequential implant, 1, 2, and 3 years after bilateral implants. The measures include localization, speech recognition in quiet and background noise, speech production, listening, vocabulary, parental perception, quality of life, and surgical data including complications. The audit has now passed the 2-year point, and data have been received on 850 children. This article provides a first view of some data received up until March 2012.

  17. Surgical Management of the Pediatric Cochlear Implant Patient.

    ERIC Educational Resources Information Center

    Cohen, Seth M.; Haynes, David S.

    2003-01-01

    This article discusses the surgical management of children receiving cochlear implants. It identifies preoperative considerations to select patients likely to benefit, contraindications, some new surgical techniques, complications, special considerations (otitis media, meningitis, head growth, inner ear malformations, and cochlear obstruction).…

  18. Is the Cochlear Amplifier a Fluid Pump?

    NASA Astrophysics Data System (ADS)

    Karavitaki, K. D.; Mountain, D. C.

    2003-02-01

    We have visualized and quantified the effects of electrically evoked motility of outer hair cells (OHCs) within the organ of Corti using an excised cochlear preparation. We found that OHC motility induces oscillatory fluid flow in the tunnel of Corti (TC) and this flow is present at physiologically relevant frequencies. We also show, using a simple one-dimensional hydromechanical model of the TC, that a fluid wave within the tunnel can travel without significant attenuation for distances larger than the wavelength of the cochlear traveling wave. These results in combination with a recent hypothesis that fluid flow within the tunnel is necessary for cochlear amplification suggest that the function of the OHCs is to act as a fluid pump.

  19. First record of eocene bony fishes and crocodyliforms from Canada's Western Arctic.

    PubMed

    Eberle, Jaelyn J; Gottfried, Michael D; Hutchison, J Howard; Brochu, Christopher A

    2014-01-01

    Discovery of Eocene non-marine vertebrates, including crocodylians, turtles, bony fishes, and mammals in Canada's High Arctic was a critical paleontological contribution of the last century because it indicated that this region of the Arctic had been mild, temperate, and ice-free during the early - middle Eocene (∼53-50 Ma), despite being well above the Arctic Circle. To date, these discoveries have been restricted to Canada's easternmost Arctic - Ellesmere and Axel Heiberg Islands (Nunavut). Although temporally correlative strata crop out over 1,000 km west, on Canada's westernmost Arctic Island - Banks Island, Northwest Territories - they have been interpreted as predominantly marine. We document the first Eocene bony fish and crocodyliform fossils from Banks Island. We describe fossils of bony fishes, including lepisosteid (Atractosteus), esocid (pike), and amiid, and a crocodyliform, from lower - middle Eocene strata of the Cyclic Member, Eureka Sound Formation within Aulavik National Park (∼76°N. paleolat.). Palynology suggests the sediments are late early to middle Eocene in age, and likely spanned the Early Eocene Climatic Optimum (EECO). These fossils extend the geographic range of Eocene Arctic lepisosteids, esocids, amiids, and crocodyliforms west by approximately 40° of longitude or ∼1100 km. The low diversity bony fish fauna, at least at the family level, is essentially identical on Ellesmere and Banks Islands, suggesting a pan-High Arctic bony fish fauna of relatively basal groups around the margin of the Eocene Arctic Ocean. From a paleoclimatic perspective, presence of a crocodyliform, gar and amiid fishes on northern Banks provides further evidence that mild, year-round temperatures extended across the Canadian Arctic during early - middle Eocene time. Additionally, the Banks Island crocodyliform is consistent with the phylogenetic hypothesis of a Paleogene divergence time between the two extant alligatorid lineages Alligator

  20. A prospective study evaluating cochlear implant management skills: development and validation of the Cochlear Implant Management Skills survey.

    PubMed

    Bennett, R J; Jayakody, D M P; Eikelboom, R H; Taljaard, D S; Atlas, M D

    2016-02-01

    To investigate the ability of cochlear implant (CI) recipients to physically handle and care for their hearing implant device(s) and to identify factors that may influence skills. To assess device management skills, a clinical survey was developed and validated on a clinical cohort of CI recipients. Survey development and validation. A prospective convenience cohort design study. Specialist hearing implant clinic. Forty-nine post-lingually deafened, adult CI recipients, at least 12 months postoperative. Survey test-retest reliability, interobserver reliability and responsiveness. Correlations between management skills and participant demographic, audiometric, clinical outcomes and device factors. The Cochlear Implant Management Skills survey was developed, demonstrating high test-retest reliability (0.878), interobserver reliability (0.972) and responsiveness to intervention (skills training) [t(20) = -3.913, P = 0.001]. Cochlear Implant Management Skills survey scores range from 54.69% to 100% (mean: 83.45%, sd: 12.47). No associations were found between handling skills and participant factors. This is the first study to demonstrate a range in cochlear implant device handling skills in CI recipients and offers clinicians and researchers a tool to systematically and objectively identify shortcomings in CI recipients' device handling skills. © 2015 John Wiley & Sons Ltd.

  1. Petrosal anatomy and inner ear structures of the Late Jurassic Henkelotherium (Mammalia, Cladotheria, Dryolestoidea): insight into the early evolution of the ear region in cladotherian mammals

    PubMed Central

    Ruf, Irina; Luo, Zhe-Xi; Wible, John R; Martin, Thomas

    2009-01-01

    The petrosal anatomy and inner ear structure of Jurassic cladotherian mammals represent the ancestral morphological conditions (groundplan) from which modern therian mammals (marsupials and placentals) have evolved. We present the reconstruction of the petrosal and inner ear features of the Late Jurassic dryolestoid mammal Henkelotherium guimarotae from high-resolution computed tomography and three-dimensional imaging analysis. This study of Henkelotherium revealed a combination of derived and primitive features, including: cladotherian apomorphies, such as the promontorial sulcus for the internal carotid artery and reduced lateral trough; trechnotherian characters, such as an enclosed cochlear canaliculus for the perilymphatic duct, post-promontorial tympanic sinus and caudal tympanic process; in addition to plesiomorphic mammalian features, such as the cavum supracochleare and prootic canal. The inner ear of Henkelotherium shows a division between the utricle and saccule, a cochlear canal coiled through at least 270°, a distinctive primary bony lamina for the basilar membrane, and a secondary bony lamina. The development of the primary and secondary bony laminae in the cochlear canal is suggested here to be correlated with the concurrent coiling of the bony canal and membranous duct of the inner ear cochlea, apomorphies of the more inclusive cladotherian clade that also represent the ancestral morphotype of modern therian mammals. Because these features are crucial for high-frequency hearing in extant therian mammals, their early appearance in Late Jurassic cladotherians suggests a more ancient origination for high-frequency hearing in mammalian history than previously thought. PMID:19438763

  2. Cochlear implantation in adults with asymmetric hearing loss.

    PubMed

    Firszt, Jill B; Holden, Laura K; Reeder, Ruth M; Cowdrey, Lisa; King, Sarah

    2012-01-01

    Bilateral severe to profound sensorineural hearing loss is a standard criterion for cochlear implantation. Increasingly, patients are implanted in one ear and continue to use a hearing aid in the nonimplanted ear to improve abilities such as sound localization and speech understanding in noise. Patients with severe to profound hearing loss in one ear and a more moderate hearing loss in the other ear (i.e., asymmetric hearing) are not typically considered candidates for cochlear implantation. Amplification in the poorer ear is often unsuccessful because of limited benefit, restricting the patient to unilateral listening from the better ear alone. The purpose of this study was to determine whether patients with asymmetric hearing loss could benefit from cochlear implantation in the poorer ear with continued use of a hearing aid in the better ear. Ten adults with asymmetric hearing between ears participated. In the poorer ear, all participants met cochlear implant candidacy guidelines; seven had postlingual onset, and three had pre/perilingual onset of severe to profound hearing loss. All had open-set speech recognition in the better-hearing ear. Assessment measures included word and sentence recognition in quiet, sentence recognition in fixed noise (four-talker babble) and in diffuse restaurant noise using an adaptive procedure, localization of word stimuli, and a hearing handicap scale. Participants were evaluated preimplant with hearing aids and postimplant with the implant alone, the hearing aid alone in the better ear, and bimodally (the implant and hearing aid in combination). Postlingual participants were evaluated at 6 mo postimplant, and pre/perilingual participants were evaluated at 6 and 12 mo postimplant. Data analysis compared the following results: (1) the poorer-hearing ear preimplant (with hearing aid) and postimplant (with cochlear implant); (2) the device(s) used for everyday listening pre- and postimplant; and (3) the hearing aid-alone and bimodal

  3. Cochlear Implantation in Adults with Asymmetric Hearing Loss

    PubMed Central

    Firszt, Jill B.; Holden, Laura K.; Reeder, Ruth M.; Cowdrey, Lisa; King, Sarah

    2012-01-01

    Objective Bilateral severe-to-profound sensorineural hearing loss is a standard criterion for cochlear implantation. Increasingly, patients are implanted in one ear and continue to use a hearing aid in the non-implanted ear to improve abilities such as sound localization and speech understanding in noise. Patients with severe-to-profound hearing loss in one ear and a more moderate hearing loss in the other ear (i.e., asymmetric hearing) are not typically considered candidates for cochlear implantation. Amplification in the poorer ear is often unsuccessful due to limited benefit, restricting the patient to unilateral listening from the better ear alone. The purpose of this study was to determine if patients with asymmetric hearing loss could benefit from cochlear implantation in the poorer ear with continued use of a hearing aid in the better ear. Design Ten adults with asymmetric hearing between ears participated. In the poorer ear, all participants met cochlear implant candidacy guidelines; seven had postlingual onset and three had pre/perilingual onset of severe-to-profound hearing loss. All had open-set speech recognition in the better hearing ear. Assessment measures included word and sentence recognition in quiet, sentence recognition in fixed noise (four-talker babble) and in diffuse restaurant noise using an adaptive procedure, localization of word stimuli and a hearing handicap scale. Participants were evaluated pre-implant with hearing aids and post-implant with the implant alone, the hearing aid alone in the better ear and bimodally (the implant and hearing aid in combination). Postlingual participants were evaluated at six months post-implant and pre/perilingual participants were evaluated at six and 12 months post-implant. Data analysis compared results 1) of the poorer hearing ear pre-implant (with hearing aid) and post-implant (with cochlear implant), 2) with the device(s) used for everyday listening pre- and post-implant and, 3) between the hearing

  4. The Relationship between Cochlear Implants and Deaf Identity

    ERIC Educational Resources Information Center

    Chapman, Madeline; Dammeyer, Jesper

    2017-01-01

    The degree to which individuals with cochlear implants (CIs) experience communication difficulties has implications for social participation and identity development. However, few studies have examined the relationship between cochlear implantation, identity, and social participation. Using data from a Danish national survey of deaf adults, the…

  5. [Inconformity between soft tissue defect and bony defect in incomplete cleft palate].

    PubMed

    Zhou, Xia; Ma, Lian

    2014-12-01

    To evaluate the inconformity between soft tissue defect and bony defect by observing the cleft extent of palate with complete secondary palate bony cleft in incomplete cleft palate patient. The patients with incomplete cleft palate treated in Hospital of Stomatology Peking University from July 2012 to June 2013 were reviewed, of which 75 cases with complete secondary palate bony cleft were selected in this study. The CT scan and intraoral photograph were taken before operation. The patients were classified as four types according to the extent of soft tissue defect. Type 1: soft tissue defect reached incisive foremen region, Type 2 was hard and soft cleft palate, Type 3 soft cleft palate and Type 4 submucous cleft palate. Type 1 was defined as conformity group (CG). The other three types were defined as inconformity group (ICG) and divided into three subgroups (ICG-I), (ICG-II) and (ICG-III). Fifty-seven patients were in ICG group, and the rate of inconformity was 76% (57/75). The percentage of ICG-I, ICG-II and ICG-III was 47% (27/57), 23% (13/57) and 30% (17/57), respevtively. There are different types of soft tissue deformity with complete secondary palate bony cleft. The inconformity between soft tissue and hard tissue defect exits in 3/4 of isolated cleft palate patients.

  6. Verbal Working Memory in Children With Cochlear Implants

    PubMed Central

    Caldwell-Tarr, Amanda; Low, Keri E.; Lowenstein, Joanna H.

    2017-01-01

    Purpose Verbal working memory in children with cochlear implants and children with normal hearing was examined. Participants Ninety-three fourth graders (47 with normal hearing, 46 with cochlear implants) participated, all of whom were in a longitudinal study and had working memory assessed 2 years earlier. Method A dual-component model of working memory was adopted, and a serial recall task measured storage and processing. Potential predictor variables were phonological awareness, vocabulary knowledge, nonverbal IQ, and several treatment variables. Potential dependent functions were literacy, expressive language, and speech-in-noise recognition. Results Children with cochlear implants showed deficits in storage and processing, similar in size to those at second grade. Predictors of verbal working memory differed across groups: Phonological awareness explained the most variance in children with normal hearing; vocabulary explained the most variance in children with cochlear implants. Treatment variables explained little of the variance. Where potentially dependent functions were concerned, verbal working memory accounted for little variance once the variance explained by other predictors was removed. Conclusions The verbal working memory deficits of children with cochlear implants arise due to signal degradation, which limits their abilities to acquire phonological awareness. That hinders their abilities to store items using a phonological code. PMID:29075747

  7. [Ultrastructure of granulocytes of bony fishes (orders Salmoniformes, Cypriniformes, Perciformes)].

    PubMed

    Flerova, E A; Balabanova, L V

    2013-01-01

    Analysis of data on utrastructure of granulocytes of freshwater and marine bony fish of orders Salmoniformes, Cypriniformes, and Perciformes showed that in all studied species there were revealed two types of granulocytes - neutrophils and eosinophils. The exception was the bluefish Pomatomus saltatrix L. whose pronephros hemopoietic tissue was found to contain one type of the granulocytic line - neutrophils. The identification parameters of granular leukocytes are specific granules filling the cytoplasm. The main form of specific granules in neutrophils of bony fish of various phylogenetic groups is an elongated granule with different distribution of fibrils or a granule that has crystalloid formed from fibrils. The main form of eosinophil granules - large, electron-dense, homogenous.

  8. Bony defect of palate and vomer in submucous cleft palate patients.

    PubMed

    Ren, S; Ma, L; Zhou, X; Sun, Z

    2015-01-01

    The aim of this study was to visualize bony defects of the palate and vomer in submucous cleft palate patients (SMCP) by three-dimensional (3D) computed tomography (CT) reconstruction and to classify the range of bony defects. Forty-eight consecutive non-operated SMCP patients were included. Diagnosis was based on the presence of at least one of three classical signs of SMCP: bifid uvula, a translucent zone in the midline of the soft palate, and a palpable 'V' notch on the posterior border of the bony palate. Patients were imaged using spiral CT. 3D reconstruction models were created of the palate and vomer. The sagittal extent of the bony cleft in SMCP was classified into four types: type I, no V-shaped hard palate cleft (8.3%); type II, cleft involving the partial palate (43.8%); type III, cleft involving the complete palate and extending to the incisive foramen (43.8%); type IV, cleft involving the complete palate and the alveolar bone (4.2%). The extent of the vomer defect was classified into three types: type A, vomer completely fused with the palate (8.3%); type B, vomer partially fused with the palate (43.8%); type C, vomer not fused with the palate up to the incisive foramen (47.9%). Significant variability in hard palate defects in SMCP is the rule rather than the exception. The association of velopharyngeal insufficiency with anatomical malformations may be complex. Copyright © 2014 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  9. Cochlear implantation for single-sided deafness and tinnitus suppression.

    PubMed

    Holder, Jourdan T; O'Connell, Brendan; Hedley-Williams, Andrea; Wanna, George

    To quantify the potential effectiveness of cochlear implantation for tinnitus suppression in patients with single-sided deafness using the Tinnitus Handicap Inventory. The study included 12 patients with unilateral tinnitus who were undergoing cochlear implantation for single-sided deafness. The Tinnitus Handicap Inventory was administered at the patient's cochlear implant candidacy evaluation appointment prior to implantation and every cochlear implant follow-up appointment, except activation, following implantation. Patient demographics and speech recognition scores were also retrospectively recorded using the electronic medical record. A significant reduction was found when comparing Tinnitus Handicap Inventory score preoperatively (61.2±27.5) to the Tinnitus Handicap Inventory score after three months of cochlear implant use (24.6±28.2, p=0.004) and the Tinnitus Handicap Inventory score beyond 6months of CI use (13.3±18.9, p=0.008). Further, 45% of patients reported total tinnitus suppression. Mean CNC word recognition score improved from 2.9% (SD 9.4) pre-operatively to 40.8% (SD 31.7) by 6months post-activation, which was significantly improved from pre-operative scores (p=0.008). The present data is in agreement with previously published studies that have shown an improvement in tinnitus following cochlear implantation for the large majority of patients with single-sided deafness. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. DIAGNOSTIC CRITERIA FOR PROLIFERATIVE THYROID LESIONS IN BONY FISHES

    EPA Science Inventory

    Thyroid proliferative lesions are rather common in bony fishes but disagreement exists in the fish pathology community concerning diagnostic criteria for hyperplastic versus neoplastic lesions. To simplify the diagnosis of proliferative thyroid lesions and to reduce confusion reg...

  11. Spoken language development in children following cochlear implantation.

    PubMed

    Niparko, John K; Tobey, Emily A; Thal, Donna J; Eisenberg, Laurie S; Wang, Nae-Yuh; Quittner, Alexandra L; Fink, Nancy E

    2010-04-21

    Cochlear implantation is a surgical alternative to traditional amplification (hearing aids) that can facilitate spoken language development in young children with severe to profound sensorineural hearing loss (SNHL). To prospectively assess spoken language acquisition following cochlear implantation in young children. Prospective, longitudinal, and multidimensional assessment of spoken language development over a 3-year period in children who underwent cochlear implantation before 5 years of age (n = 188) from 6 US centers and hearing children of similar ages (n = 97) from 2 preschools recruited between November 2002 and December 2004. Follow-up completed between November 2005 and May 2008. Performance on measures of spoken language comprehension and expression (Reynell Developmental Language Scales). Children undergoing cochlear implantation showed greater improvement in spoken language performance (10.4; 95% confidence interval [CI], 9.6-11.2 points per year in comprehension; 8.4; 95% CI, 7.8-9.0 in expression) than would be predicted by their preimplantation baseline scores (5.4; 95% CI, 4.1-6.7, comprehension; 5.8; 95% CI, 4.6-7.0, expression), although mean scores were not restored to age-appropriate levels after 3 years. Younger age at cochlear implantation was associated with significantly steeper rate increases in comprehension (1.1; 95% CI, 0.5-1.7 points per year younger) and expression (1.0; 95% CI, 0.6-1.5 points per year younger). Similarly, each 1-year shorter history of hearing deficit was associated with steeper rate increases in comprehension (0.8; 95% CI, 0.2-1.2 points per year shorter) and expression (0.6; 95% CI, 0.2-1.0 points per year shorter). In multivariable analyses, greater residual hearing prior to cochlear implantation, higher ratings of parent-child interactions, and higher socioeconomic status were associated with greater rates of improvement in comprehension and expression. The use of cochlear implants in young children was

  12. Voice emotion perception and production in cochlear implant users.

    PubMed

    Jiam, N T; Caldwell, M; Deroche, M L; Chatterjee, M; Limb, C J

    2017-09-01

    Voice emotion is a fundamental component of human social interaction and social development. Unfortunately, cochlear implant users are often forced to interface with highly degraded prosodic cues as a result of device constraints in extraction, processing, and transmission. As such, individuals with cochlear implants frequently demonstrate significant difficulty in recognizing voice emotions in comparison to their normal hearing counterparts. Cochlear implant-mediated perception and production of voice emotion is an important but relatively understudied area of research. However, a rich understanding of the voice emotion auditory processing offers opportunities to improve upon CI biomedical design and to develop training programs benefiting CI performance. In this review, we will address the issues, current literature, and future directions for improved voice emotion processing in cochlear implant users. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. fMRI as a Preimplant Objective Tool to Predict Postimplant Oral Language Outcomes in Children with Cochlear Implants.

    PubMed

    Deshpande, Aniruddha K; Tan, Lirong; Lu, Long J; Altaye, Mekibib; Holland, Scott K

    2016-01-01

    Despite the positive effects of cochlear implantation, postimplant variability in speech perception and oral language outcomes is still difficult to predict. The aim of this study was to identify neuroimaging biomarkers of postimplant speech perception and oral language performance in children with hearing loss who receive a cochlear implant. The authors hypothesized positive correlations between blood oxygen level-dependent functional magnetic resonance imaging (fMRI) activation in brain regions related to auditory language processing and attention and scores on the Clinical Evaluation of Language Fundamentals-Preschool, Second Edition (CELF-P2) and the Early Speech Perception Test for Profoundly Hearing-Impaired Children (ESP), in children with congenital hearing loss. Eleven children with congenital hearing loss were recruited for the present study based on referral for clinical MRI and other inclusion criteria. All participants were <24 months at fMRI scanning and <36 months at first implantation. A silent background fMRI acquisition method was performed to acquire fMRI during auditory stimulation. A voxel-based analysis technique was utilized to generate z maps showing significant contrast in brain activation between auditory stimulation conditions (spoken narratives and narrow band noise). CELF-P2 and ESP were administered 2 years after implantation. Because most participants reached a ceiling on ESP, a voxel-wise regression analysis was performed between preimplant fMRI activation and postimplant CELF-P2 scores alone. Age at implantation and preimplant hearing thresholds were controlled in this regression analysis. Four brain regions were found to be significantly correlated with CELF-P2 scores. These clusters of positive correlation encompassed the temporo-parieto-occipital junction, areas in the prefrontal cortex and the cingulate gyrus. For the story versus silence contrast, CELF-P2 core language score demonstrated significant positive correlation with

  14. Modelling cochlear mechanics.

    PubMed

    Ni, Guangjian; Elliott, Stephen J; Ayat, Mohammad; Teal, Paul D

    2014-01-01

    The cochlea plays a crucial role in mammal hearing. The basic function of the cochlea is to map sounds of different frequencies onto corresponding characteristic positions on the basilar membrane (BM). Sounds enter the fluid-filled cochlea and cause deflection of the BM due to pressure differences between the cochlear fluid chambers. These deflections travel along the cochlea, increasing in amplitude, until a frequency-dependent characteristic position and then decay away rapidly. The hair cells can detect these deflections and encode them as neural signals. Modelling the mechanics of the cochlea is of help in interpreting experimental observations and also can provide predictions of the results of experiments that cannot currently be performed due to technical limitations. This paper focuses on reviewing the numerical modelling of the mechanical and electrical processes in the cochlea, which include fluid coupling, micromechanics, the cochlear amplifier, nonlinearity, and electrical coupling.

  15. Modelling Cochlear Mechanics

    PubMed Central

    Elliott, Stephen J.; Teal, Paul D.

    2014-01-01

    The cochlea plays a crucial role in mammal hearing. The basic function of the cochlea is to map sounds of different frequencies onto corresponding characteristic positions on the basilar membrane (BM). Sounds enter the fluid-filled cochlea and cause deflection of the BM due to pressure differences between the cochlear fluid chambers. These deflections travel along the cochlea, increasing in amplitude, until a frequency-dependent characteristic position and then decay away rapidly. The hair cells can detect these deflections and encode them as neural signals. Modelling the mechanics of the cochlea is of help in interpreting experimental observations and also can provide predictions of the results of experiments that cannot currently be performed due to technical limitations. This paper focuses on reviewing the numerical modelling of the mechanical and electrical processes in the cochlea, which include fluid coupling, micromechanics, the cochlear amplifier, nonlinearity, and electrical coupling. PMID:25136555

  16. Cochlear Patency After Transmastoid Labyrinthectomy for Ménière's Syndrome.

    PubMed

    Sargent, Eric W; Liao, Eric; Gonda, Roger L

    2016-08-01

    Labyrinthectomy is considered the "gold standard" in the treatment of intractable vertigo attacks because of Ménière's Disease (MD) but sacrifices all residual hearing. Interest in auditory rehabilitation has lead to cochlear implantation in some patients. Concern remains that the cochlear lumen may fill with tissue or bone after surgery. This study sought to determine the incidence of obliteration of the cochlea after transmastoid labyrinthectomy. Retrospective observational study. Tertiary referral center. Eighteen patients with intractable vertigo from MD who underwent surgery. Transmastoid labyrinthectomy between 2008 and 2013. Cochleas were imaged with unenhanced, heavily T2-weighted magnetic resonance imaging (MRI). Presence of symmetrical cochlear fluid signals on MRI. There was no loss of fluid signal in the cochleas of operated ear compared with the contralateral, unoperated ear in any subject an average of 3 years (standard deviation [SD]: 1.2) after surgery. Five of 18 patients had the vestibule blocked with bone wax at the time of surgery. Blocking the vestibule with bone wax did not change the cochlear fluid signal. The risk of cochlear obstruction after labyrinthectomy for MD is very low. The significance of this finding is that patients with MD who undergo labyrinthectomy will likely remain candidates for cochlear implantation in the labyrinthectomized ear long after surgery if this becomes needed. Immediate cochlear implantation or placement of a cochlear lumen keeper during labyrinthectomy for MD is probably not necessary.

  17. International classification of reliability for implanted cochlear implant receiver stimulators.

    PubMed

    Battmer, Rolf-Dieter; Backous, Douglas D; Balkany, Thomas J; Briggs, Robert J S; Gantz, Bruce J; van Hasselt, Andrew; Kim, Chong Sun; Kubo, Takeshi; Lenarz, Thomas; Pillsbury, Harold C; O'Donoghue, Gerard M

    2010-10-01

    To design an international standard to be used when reporting reliability of the implanted components of cochlear implant systems to appropriate governmental authorities, cochlear implant (CI) centers, and for journal editors in evaluating manuscripts involving cochlear implant reliability. The International Consensus Group for Cochlear Implant Reliability Reporting was assembled to unify ongoing efforts in the United States, Europe, Asia, and Australia to create a consistent and comprehensive classification system for the implanted components of CI systems across manufacturers. All members of the consensus group are from tertiary referral cochlear implant centers. None. A clinically relevant classification scheme adapted from principles of ISO standard 5841-2:2000 originally designed for reporting reliability of cardiac pacemakers, pulse generators, or leads. Standard definitions for device failure, survival time, clinical benefit, reduced clinical benefit, and specification were generated. Time intervals for reporting back to implant centers for devices tested to be "out of specification," categorization of explanted devices, the method of cumulative survival reporting, and content of reliability reports to be issued by manufacturers was agreed upon by all members. The methodology for calculating Cumulative survival was adapted from ISO standard 5841-2:2000. The International Consensus Group on Cochlear Implant Device Reliability Reporting recommends compliance to this new standard in reporting reliability of implanted CI components by all manufacturers of CIs and the adoption of this standard as a minimal reporting guideline for editors of journals publishing cochlear implant research results.

  18. DIAGNOSTIC CRITERIA FOR PROLIFERATIVE THYROID LESIONS IN BONY FISHES

    EPA Science Inventory

    Criteria for distinguishing hyperplastic thyroid lesions from thyroid neoplasia in bony fishes have long been debated by scientists. Confusion exists because the thyroid tissue in most teleosts is unencapsulated, is occasionally found in ectopic sites, and is frequently predispos...

  19. Bilateral cochlear implantation in a patient with bilateral temporal bone fractures.

    PubMed

    Chung, Jae Ho; Shin, Myung Chul; Min, Hyun Jung; Park, Chul Won; Lee, Seung Hwan

    2011-01-01

    With the emphasis on bilateral hearing nowadays, bilateral cochlear implantation has been tried out for bilateral aural rehabilitation. Bilateral sensorineural hearing loss caused by head trauma can get help from cochlear implantation. We present the case of a 44-year-old man with bilateral otic capsule violating temporal bone fractures due to head trauma. The patient demonstrated much improved audiometric and psychoacoustic performance after bilateral cochlear implantation. We believe bilateral cochlear implantation in such patient can be a very effective tool for rehabilitation. Copyright © 2011 Elsevier Inc. All rights reserved.

  20. Scala vestibuli cochlear implantation in patients with partially ossified cochleas.

    PubMed

    Berrettini, Stefano; Forli, Francesca; Neri, Emanuele; Segnini, Giovanni; Franceschini, Stefano Sellari

    2002-11-01

    Partial cochlear obstruction is a relatively common finding in candidates for cochlear implants and frequently involves the inferior segment of the scala tympani in the basal turn of the cochlea. In such patients, the scala vestibuli is often patent and offers an alternative site for implantation. The current report describes two patients with such partial obstruction of the inferior segment of the basal cochlear turn, caused in one case by systemic vasculitis (Takayasu's disease) and in the other by obliterative otosclerosis. A scala vestibuli implantation allowed for complete insertion of the electrode array. No problems were encountered during the surgical procedures and the good post-operative hearing and communicative outcomes achieved were similar to those reported in patients without cochlear ossification. The importance of accurate pre-operative radiological study of the inner ear is underscored, to disclose the presence and define the features of the cochlear ossification and ultimately to properly plan the surgical approach.

  1. Modulation of Mcl-1 expression reduces age-related cochlear degeneration

    PubMed Central

    Yang, Wei Ping; Xu, Yang; Guo, Wei Wei; Liu, Hui Zhan; Hu, Bo Hua

    2013-01-01

    Mcl-1 is an anti-apoptotic member of the Bcl-2 family that modulates apoptosis-related signaling pathways and promotes cell survival. We have previously demonstrated a reduction of Mcl-1 expression in aging cochleae. To investigate whether restoring Mcl-1 expression would reduce aging-related cochlear degeneration, we developed a rat model of Mcl-1 overexpression. A plasmid encoding human Mcl-1/enhanced green fluorescent protein was applied to the round window of the cochlea. This in vivo treatment transfected both the sensory and supporting cells of the cochlear sensory epithelium and enhanced Mcl-1 expression at both the mRNA and the protein level. The upregulation of Mcl-1 expression reduced the progression of age-related cochlear dysfunction and sensory cell death. Furthermore, the transfection of Mcl-1 exerted its protective effect by suppressing cochlear apoptosis at the mitochondrial level. This study demonstrates that the genetic modulation of Mcl-1 expression reduces the progression of age-related cochlear degeneration. PMID:23790646

  2. Cochlear dysfunction in hyperuricemia: otoacoustic emission analysis.

    PubMed

    Hamed, Sherifa A; El-Attar, Amal M

    2010-01-01

    The objective of this study is to provide evidence that primary hyperuricemia is associated with cochlear dysfunction as other metabolic diseases that interfere with cell metabolism. Cochlear function was evaluated in 25 subjects with asymptomatic hyperuricemia using routine diagnostic audiometry along with transient evoked and distortion product otoacoustic emissions (TEOAE and DPOAE, respectively). To support the notion that vascular compromise was a significant underlying factor for such cochlear dysfunction, we assessed vascular anatomical and functional states through measuring the common carotid artery intima-media thickness and flow velocity of the basal intracranial vessels. Compared with control subjects, reduced response levels of TEOAEs (P < .01) and amplitudes of DPOAEs (P < .001) were detected at higher frequencies. The reduced DPOAE levels at 5 kHz and TEOAEs at 4 kHz correlated significantly with uric acid (P < .05; P < .01), patients' age (P < .06; P < .05), duration since diagnosis of hyperuricemia (P < .05; P < .001), common carotid artery intima-media thickness (P < .05), mean flow velocities of middle cerebral arteries (P < .05), and vertebral arteries (P < .01). Multivariate analysis showed that the abnormalities at higher frequencies were significantly correlated with the duration and degree of hyperuricemia. These data suggest that subclinical changes in cochlear function are associated with hyperuricemia. They support the usefulness of otoacoustic emissions in early detection of cochlear dysfunction. It is possible that hyperuricemia could be accompanied by increased stiffness and/or compromise of blood supply of the outer hair cells, which will impair their electromotile response. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  3. Observations on the bony bridging of the jugular foramen in man.

    PubMed

    Dodo, Y

    1986-02-01

    The anatomical nature and pattern of incidence of bony bridging of the jugular foramen was investigated using 64 fetal crania aged nine months to term and 222 adult crania of Japanese. In addition, the region of the jugular foramen of an adult cadaver was carefully dissected in order to clarify the relationship between the cranial nerves passing through the jugular foramen and the intrajugular processes of the jugular foramen. The general conclusions concerning the anatomical nature of the bony bridging of the jugular foramen were as follows. (1) The intrajugular process of the temporal bone is situated posterior to the triangular depression (as described in Gray's Anatomy) of the petrous part. (2) The bony bridging of the jugular foramen is established by the contact of the intrajugular process of the temporal bone with the bony process of the occipital bone projecting either from just above the hypoglossal canal (Type I) or from posterior to the hypoglossal canal (Type III). (3) If both the processes of the occipital bone reach the intrajugular process of the temporal bone simultaneously, the jugular foramen is divided into three compartments. (4) In the case of Type I bridging, the anteromedial compartment transmits the glossopharyngeal nerve, while the posterolateral compartment gives passage to the vagus nerve, the accessory nerve and the internal jugular vein. (5) In the case of Type II bridging, the anteromedial compartment contains the glossopharyngeal, vagus and accessory nerves, and the posterolateral compartment transmits the internal jugular vein. (6) When tripartite division of the jugular foramen occurs, the anteromedial compartment transmits the glossopharyngeal nerve, the middle compartment contains the vagus and accessory nerves, and the posterolateral compartment transmits the internal jugular vein. Concerning the pattern of incidence of jugular foramen bridging in the Japanese fetal and adult cranial series, this is similar to that of the bony

  4. Observations on the bony bridging of the jugular foramen in man.

    PubMed Central

    Dodo, Y

    1986-01-01

    The anatomical nature and pattern of incidence of bony bridging of the jugular foramen was investigated using 64 fetal crania aged nine months to term and 222 adult crania of Japanese. In addition, the region of the jugular foramen of an adult cadaver was carefully dissected in order to clarify the relationship between the cranial nerves passing through the jugular foramen and the intrajugular processes of the jugular foramen. The general conclusions concerning the anatomical nature of the bony bridging of the jugular foramen were as follows. (1) The intrajugular process of the temporal bone is situated posterior to the triangular depression (as described in Gray's Anatomy) of the petrous part. (2) The bony bridging of the jugular foramen is established by the contact of the intrajugular process of the temporal bone with the bony process of the occipital bone projecting either from just above the hypoglossal canal (Type I) or from posterior to the hypoglossal canal (Type III). (3) If both the processes of the occipital bone reach the intrajugular process of the temporal bone simultaneously, the jugular foramen is divided into three compartments. (4) In the case of Type I bridging, the anteromedial compartment transmits the glossopharyngeal nerve, while the posterolateral compartment gives passage to the vagus nerve, the accessory nerve and the internal jugular vein. (5) In the case of Type II bridging, the anteromedial compartment contains the glossopharyngeal, vagus and accessory nerves, and the posterolateral compartment transmits the internal jugular vein. (6) When tripartite division of the jugular foramen occurs, the anteromedial compartment transmits the glossopharyngeal nerve, the middle compartment contains the vagus and accessory nerves, and the posterolateral compartment transmits the internal jugular vein. Concerning the pattern of incidence of jugular foramen bridging in the Japanese fetal and adult cranial series, this is similar to that of the bony

  5. Music activities and responses of young cochlear implant recipients.

    PubMed

    van Besouw, Rachel M; Grasmeder, Mary L; Hamilton, Mary E; Baumann, Sarah E

    2011-05-01

    The development of auditory receptive skills and spoken language is often delayed in children who use cochlear implants, which may affect their appreciation of and responses to music. This in turn may be interpreted as disinterest in music. A questionnaire was developed to determine whether differences in exposure and responses to music exist between young cochlear implant recipients and their normally hearing peers. The questionnaire was developed by a multidisciplinary team and distributed to parents of preschool children with normal hearing and to parents of preschool children who had been implanted at least one year prior. The cochlear implant group comprised 23 children and was gender and age matched (within ±2 months) to a group of children with normal hearing. Young cochlear implant recipients receive similar exposure to audiovisual music media, parental singing and musical instruments at home. However, the data suggest that they receive less exposure to children's music presented without visual stimuli. Parents also reported less sophisticated responses to music for this group. The findings of this study have important implications concerning the provision of age-appropriate music habilitation materials and activities for young cochlear implant recipients.

  6. Current Research with Cochlear Implants at Arizona State University

    PubMed Central

    Dorman, Michael F.; Spahr, Anthony; Gifford, Rene H.; Cook, Sarah; Zhang, Ting; Loiselle, Louise; Yost, William; Cardy, Lara; Whittingham, JoAnne; Schramm, David

    2013-01-01

    In this article we review, and discuss the clinical implications of, five projects currently underway in the Cochlear Implant Laboratory at Arizona State University. The projects are (1) norming the AzBio sentence test, (2) comparing the performance of bilateral and bimodal cochlear implant (CI) patients in realistic listening environments, (3) accounting for the benefit provided to bimodal patients by low-frequency acoustic stimulation, (4) assessing localization by bilateral hearing aid patients and the implications of that work for hearing preservation patients, and (5) studying heart rate variability as a possible measure for quantifying the stress of listening via an implant. The long-term goals of the laboratory are to improve the performance of patients fit with cochlear implants and to understand the mechanisms, physiological or electronic, that underlie changes in performance. We began our work with cochlear implant patients in the mid-1980s and received our first grant from the National Institutes of Health (NIH) for work with implanted patients in 1989. Since that date our work with cochlear implant patients has been funded continuously by the NIH. In this report we describe some of the research currently being conducted in our laboratory. PMID:22668760

  7. Working memory in Farsi-speaking children with normal development and cochlear implant.

    PubMed

    Soleymani, Zahra; Amidfar, Meysam; Dadgar, Hooshang; Jalaie, Shohre

    2014-04-01

    Working memory has an important role in language acquisition and development of cognition skills. The ability of encoding, storage and retrieval of phonological codes, as activities of working memory, acquired by audition sense. Children with cochlear implant experience a period that they are not able to perceive sounds. In order to assess the effect of hearing on working memory, we investigated working memory as a cognition skill in children with normal development and cochlear implant. Fifty students with normal hearing and 50 students with cochlear implant aged 5-7 years participated in this study. Children educated in the preschool, the first and second grades. Children with normal development were matched based on age, gender, and grade of education with cochlear implant. Two components of working memory including phonological loop and central executive were compared between two groups. Phonological loop assessed by nonword repetition task and forward digit span. To assess central executive component backward digit span was used. The developmental trend was studied in children with normal development and cochlear implant as well. The effect of age at implantation in children with cochlear implants on components of working memory was investigated. There are significant differences between children with normal development and cochlear implant in all tasks that assess working memory (p < 0.001). The children's age at implantation was negatively correlated with all tasks (p < 0.001). In contrast, duration of usage of cochlear implant set was positively correlated with all tasks (p < 0.001). The comparison of working memory between different grades showed significant differences both in children with normal development and in children with cochlear implant (p < 0.05). These results implied that children with cochlear implant may experience difficulties in working memory. Therefore, these children have problems in encoding, practicing, and repeating phonological

  8. Verbal Working Memory in Children with Cochlear Implants

    ERIC Educational Resources Information Center

    Nittrouer, Susan; Caldwell-Tarr, Amanda; Low, Keri E.; Lowenstein, Joanna H.

    2017-01-01

    Purpose: Verbal working memory in children with cochlear implants and children with normal hearing was examined. Participants: Ninety-three fourth graders (47 with normal hearing, 46 with cochlear implants) participated, all of whom were in a longitudinal study and had working memory assessed 2 years earlier. Method: A dual-component model of…

  9. Quality-of-life benefit from cochlear implantation in the elderly.

    PubMed

    Vermeire, Katrien; Brokx, Jan P L; Wuyts, Floris L; Cochet, Ellen; Hofkens, Anouk; Van de Heyning, Paul H

    2005-03-01

    To compare the audiologic results of geriatric patients receiving cochlear implants with younger age groups and to evaluate the quality of life after cochlear implantation in the geriatric population by means of validated quality-of-life questionnaires. Cross-sectional study involving 89 postlingually deafened cochlear implant subjects. Tertiary referral center. A total of 89 postlingually deafened patients were included in the study, among which were 25 patients who were aged 70 years or older. All patients received a cochlear implant. Subjects were implanted with either the Laura, Nucleus 24, or Med-el Combi 40+ cochlear implant systems implementing the SPEAK, ACE, CIS, or CIS+ coding strategies. Speech recognition was determined by means of phonetically balanced monosyllabic word lists. The Hearing Handicap Inventory for Adults, the Glasgow Benefit Inventory, and the scale for the prediction of hearing disability in sensorineural hearing loss were used to quantify the quality of life. Mean audiologic performance for the three groups increased significantly after implantation (p < 0.001). Postoperative audiologic performance of the geriatric population led to useful hearing, but these scores were significantly lower than for the younger age groups (p = 0.002). However, the quality-of-life outcomes for the geriatric group were similar to those of the younger age groups (p = 0.411 for the Hearing Handicap Inventory for Adults; p = 0.886 for the Glasgow Benefit Inventory). The results of this study prove that cochlear implantation in the elderly provides improvements in quality of life and speech understanding, similar to those for younger adult cochlear implant recipients.

  10. Symmetric Electrode Spanning Narrows the Excitation Patterns of Partial Tripolar Stimuli in Cochlear Implants.

    PubMed

    Luo, Xin; Wu, Ching-Chih

    2016-12-01

    In cochlear implants (CIs), standard partial tripolar (pTP) mode reduces current spread by returning a fraction of the current to two adjacent flanking electrodes within the cochlea. Symmetric electrode spanning (i.e., separating both the apical and basal return electrodes from the main electrode by one electrode) has been shown to increase the pitch of pTP stimuli, when the ratio of intracochlear return current was fixed. To explain the pitch increase caused by symmetric spanning in pTP mode, this study measured the electrical potentials of both standard and symmetrically spanned pTP stimuli on a main electrode EL8 in five CI ears using electrical field imaging (EFI). In addition, the spatial profiles of evoked compound action potentials (ECAP) and the psychophysical forward masking (PFM) patterns were also measured for both stimuli. The EFI, ECAP, and PFM patterns of a given stimulus differed in shape details, reflecting the different levels of auditory processing and different ratios of intracochlear return current across the measurement methods. Compared to the standard pTP stimuli, the symmetrically spanned pTP stimuli significantly reduced the areas under the curves of the normalized EFI and PFM patterns, without shifting the pattern peaks and centroids (both around EL8). The more focused excitation patterns with symmetric spanning may have caused the previously reported pitch increase, due to an interaction between pitch and timbre perception. Being able to reduce the spread of excitation, pTP mode symmetric spanning is a promising stimulation strategy that may further increase spectral resolution and frequency selectivity with CIs.

  11. Blood flow to the promontory in cochlear otosclerosis.

    PubMed

    Nakashima, T; Sone, M; Fujii, H; Teranishi, M; Yamamoto, H; Otake, H; Sugiura, M; Naganawa, S

    2006-04-01

    To investigate Schwartze sign with measurements of blood flow to the promontory in patients with cochlear otosclerosis. Prospective clinical study. Tertiary referral centre. Five patients with cochlear otosclerosis and five control subjects. Significant decalcification around the cochlea was observed by computed tomography (CT) in patients with cochlear otosclerosis. However, no recognizable lesion was observed at the oval window in two patients. One patient had mixed hearing loss and four patients had sensorineural hearing loss without an air-bone gap. The relationship between CT findings and the presence or absence of Schwartze sign was investigated. Blood flow to the promontory was measured through the tympanic membrane using laser speckle flowgraphy and laser Doppler flowmetry. The Schwartze sign correlated significantly with otosclerotic lesions invading the promontory. Patients with otosclerosis exhibited elevated and pulsating blood flow to the promontory with the Schwartze sign. Computed tomography demonstrated that cochlear otosclerosis can exist without the oval window lesion. Schwartze sign can be used as a sign of the otosclerotic invasion to the promontory. The reddening of the Schwartze sign is likely due to increased blood flow.

  12. Challenges in Improving Cochlear Implant Performance and Accessibility.

    PubMed

    Zeng, Fan-Gang

    2017-08-01

    Here I identify two gaps in cochlear implants that have been limiting their performance and acceptance. First, cochlear implant performance has remained largely unchanged, despite the number of publications tripling per decade in the last 30 years. Little has been done so far to address a fundamental limitation in the electrode-to-neuron interface, with the electrode size being a thousand times larger than the neuron diameter while the number of electrodes being a thousand times less. Both the small number and the large size of electrodes produce broad spatial activation and poor frequency resolution that limit current cochlear implant performance. Second, a similarly rapid growth in cochlear implant volume has not produced an expected decrease in unit price in the same period. The high cost contributes to low market penetration rate, which is about 20% in developed countries and less than 1% in developing countries. I will discuss changes needed in both research strategy and business practice to close the gap between prosthetic and normal hearing as well as that between haves and have-nots.

  13. Cochlear implantation in Waardenburg syndrome: The Indian scenario.

    PubMed

    Deka, Ramesh Chandra; Sikka, Kapil; Chaturvedy, Gaurav; Singh, Chirom Amit; Venkat Karthikeyan, C; Kumar, Rakesh; Agarwal, Shivani

    2010-10-01

    Children with Waardenburg syndrome (WS) exhibiting normal inner ear anatomy, like those included in our cohort, derive significant benefit from cochlear implantation and results are comparable to those reported for the general population of implanted children. The patient population of WS accounts for approximately 2% of congenitally deaf children. The purpose of this retrospective case review was to describe the outcomes for those children with WS who have undergone cochlear implantation. On retrospective chart review, there were four cases with WS who underwent cochlear implantation. These cases were assessed for age at implantation, clinical and radiological features, operative and perioperative course, and performance outcomes. Auditory perception and speech production ability were evaluated using categories of auditory performance (CAP), meaningful auditory integration scales (MAIS), and speech intelligibility rating (SIR) during the follow-up period. In this group of children with WS, with a minimum follow-up of 12 months, the CAP score ranged from 3 to 5, MAIS from 25 to 30, and SIR was 3. These scores are comparable with those of other cochlear implantees.

  14. The benefits of remote microphone technology for adults with cochlear implants.

    PubMed

    Fitzpatrick, Elizabeth M; Séguin, Christiane; Schramm, David R; Armstrong, Shelly; Chénier, Josée

    2009-10-01

    Cochlear implantation has become a standard practice for adults with severe to profound hearing loss who demonstrate limited benefit from hearing aids. Despite the substantial auditory benefits provided by cochlear implants, many adults experience difficulty understanding speech in noisy environments and in other challenging listening conditions such as television. Remote microphone technology may provide some benefit in these situations; however, little is known about whether these systems are effective in improving speech understanding in difficult acoustic environments for this population. This study was undertaken with adult cochlear implant recipients to assess the potential benefits of remote microphone technology. The objectives were to examine the measurable and perceived benefit of remote microphone devices during television viewing and to assess the benefits of a frequency-modulated system for speech understanding in noise. Fifteen adult unilateral cochlear implant users were fit with remote microphone devices in a clinical environment. The study used a combination of direct measurements and patient perceptions to assess speech understanding with and without remote microphone technology. The direct measures involved a within-subject repeated-measures design. Direct measures of patients' speech understanding during television viewing were collected using their cochlear implant alone and with their implant device coupled to an assistive listening device. Questionnaires were administered to document patients' perceptions of benefits during the television-listening tasks. Speech recognition tests of open-set sentences in noise with and without remote microphone technology were also administered. Participants showed improved speech understanding for television listening when using remote microphone devices coupled to their cochlear implant compared with a cochlear implant alone. This benefit was documented both when listening to news and talk show recordings

  15. Multichannel cochlear implantation in the scala vestibuli.

    PubMed

    Lin, Karen; Marrinan, Michelle S; Waltzman, Susan B; Roland, J Thomas

    2006-08-01

    Sensorineural hearing loss resulting from otosclerosis, meningitis, chronic otitis media, autoimmune ear disease, and trauma can be associated with partial or total obstruction of the cochlear scalae. Multichannel cochlear implantation may be difficult in a cochlea with an obstructed scala tympani. The purpose of this study is to determine the safety and efficacy of scala tympani electrode insertion. Retrospective chart review. Academic medical center. Eight children and adults with profound sensorineural hearing loss who underwent cochlear implantation with known scala vestibuli electrode array insertion were subjects for this study. Eight study subjects underwent implantation: five with the Nucleus 24RCS (Contour) device and three with the Nucleus 24M device. Imaging findings, operative findings, and age-appropriate speech perception testing. All patients had full electrode insertion. Various obstructive patterns on computed tomography and magnetic resonance imaging were found, and there was a range of speech perception results. All but one patient improved based on age-appropriate monosyllabic word and sentence tests. Scala vestibuli multielectrode insertion is a viable alternative when scala tympani insertion is not possible because of abnormal anatomy or anatomical changes secondary to disease or previous implantation. We will also present an algorithm of options for decision making for implantation when encountering cochlear obstruction and difficult electrode insertion.

  16. Parents' Views on Changing Communication after Cochlear Implantation

    ERIC Educational Resources Information Center

    Watson, Linda M.; Hardie, Tim; Archbold, Sue M.; Wheeler, Alexandra

    2008-01-01

    We sent questionnaires to families of all 288 children who had received cochlear implants at one center in the United Kingdom at least 5 years previously. Thus, it was a large, unselected group. We received 142 replies and 119 indicated that the child and family had changed their communication approach following cochlear implantation. In 113 cases…

  17. Auditory cortical responses in patients with cochlear implants

    PubMed Central

    Burdo, S; Razza, S; Di Berardino, F; Tognola, G

    2006-01-01

    Summary Currently, the most commonly used electrophysiological tests for cochlear implant evaluation are Averaged Electrical Voltages (AEV), Electrical Advisory Brainstem Responses (EABR) and Neural Response Telemetry (NRT). The present paper focuses on the study of acoustic auditory cortical responses, or slow vertex responses, which are not widely used due to the difficulty in recording, especially in young children. Aims of this study were validation of slow vertex responses and their possible applications in monitoring postimplant results, particularly restoration of hearing and auditory maturation. In practice, the use of tone-bursts, also through hearing aids or cochlear implants, as in slow vertex responses, allows many more frequencies to be investigated and louder intensities to be reached than with other tests based on a click as stimulus. Study design focused on latencies of N1 and P2 slow vertex response peaks in cochlear implants. The study population comprised 45 implant recipients (aged 2 to 70 years), divided into 5 different homogeneous groups according to chronological age, age at onset of deafness, and age at implantation. For each subject, slow vertex responses and free-field auditory responses (PTAS) were recorded for tone-bursts at 500 and 2000 Hz before cochlear implant surgery (using hearing aid amplification) and during scheduled sessions at 3rd and 12th month after implant activation. Results showed that N1 and P2 latencies decreased in all groups starting from 3rd through 12th month after activation. Subjects implanted before school age or at least before age 8 yrs showed the widest latency changes. All subjects showed a reduction in the gap between subjective thresholds (obtained with free field auditory responses) and objective thresholds (obtained with slow vertex responses), obtained in presurgery stage and after cochlear implant. In conclusion, a natural evolution of neurophysiological cortical activities of the auditory pathway

  18. Cochlear Implants and Psychiatric Assessments: a Norrie Disease Case Report.

    PubMed

    Jacques, Denis; Dubois, Thomas; Zdanowicz, Nicolas; Gilain, Chantal; Garin, Pierre

    2017-09-01

    It is important to perform psychiatric assessments of adult patients who are candidates for cochlear implants both to screen them for psychiatric disorders and to assess their understanding and compliance with the procedure. Deafness is a factor of difficulty for conducting in-depth psychiatric interviews, but concomitant blindness may make it impossible. After a description of Norrie disease, a rare disease in which blindness and deafness may occur together, we propose a case report of a patient suffering from the disease and who consulted in view of a cochlear implant. Early information on cochlear implants appears to be necessary before total deafness occurs in patients suffering from Norrie disease. An inventory of digital communication tools that can be used by the patient is also highly valuable. Research should be supported for a more systematic use of psychiatric assessments prior to cochlear implants. In the special case of Norrie disease, we recommend early screening for mental retardation and related psychotic disorders and, depending on the patient's level of understanding, preventive information on the benefits and limits of cochlear implants before total deafness occurs.

  19. Meningitis following cochlear implantation: pathomechanisms, clinical symptoms, conservative and surgical treatments.

    PubMed

    Arnold, W; Bredberg, G; Gstöttner, W; Helms, J; Hildmann, H; Kiratzidis, T; Müller, J; Ramsden, R T; Roland, P; Walterspiel, J N

    2002-01-01

    Pneumococcal otogenic meningitis is a rare postsurgical complication that can develop following stapedectomy or after cochlear implantation. The bacterial infection can be fatal in some instances. A recent increase in the incidence of otogenic meningitis among cochlear implant wearers is of concern. The majority of meningitis cases are associated with a 2-component electrode manufactured by one cochlear implant company. The device with the added 'positioner' component has been withdrawn from the market (FDA Public Health Web Notification: Cochlear Implant Recipients may be at Greater Risk for Meningitis, Updated: August 29, 2002, www.fda.gov/cdrh/safety/cochlear.html). Not all cases have been subsequent to otitis media and symptoms have developed from less than 24 h up to a few years after implantation. The purpose of this paper is to review and discuss the pathogenesis, pathology/bacteriology and to elaborate on some clinical features of otogenic meningitis in implanted children and adults. Essential aspects of surgery, electrode design, and cochleostomy seal are discussed. Conclusions are drawn from the available data and recommendations are made for good practice in cochlear implantation and follow-up. Copyright 2002 S. Karger AG, Basel

  20. Early Vocabulary Development in Children with Bilateral Cochlear Implants

    ERIC Educational Resources Information Center

    Välimaa, Taina; Kunnari, Sari; Laukkanen-Nevala, Päivi; Lonka, Eila

    2018-01-01

    Background: Children with unilateral cochlear implants (CIs) may have delayed vocabulary development for an extended period after implantation. Bilateral cochlear implantation is reported to be associated with improved sound localization and enhanced speech perception in noise. This study proposed that bilateral implantation might also promote…

  1. Systemic immunity influences hearing preservation in cochlear implantation.

    PubMed

    Souter, Melanie; Eastwood, Hayden; Marovic, Paul; Kel, Gordana; Wongprasartsuk, Sarin; Ryan, Allen F; O'Leary, Stephen John

    2012-06-01

    To determine whether a systemic immune response influences hearing thresholds and tissue response after cochlear implantation of hearing guinea pigs. Guinea pigs were inoculated with sterile antigen (Keyhole limpet hemocyanin) 3 weeks before cochlear implantation. Pure-tone auditory brainstem response thresholds were performed before implantation and 1 and 4 weeks later. Dexamethasone phosphate 20% was adsorbed onto a hyaluronic acid carboxymethylcellulose sponge and was applied to the round window for 30 minutes before electrode insertion. Normal saline was used for controls. Cochlear histology was performed at 4 weeks after implantation to assess the tissue response to implantation. To control for the effect of keyhole limpet hemocyanin priming, a group of unprimed animals underwent cochlear implantation with a saline-soaked pledget applied to the round window. Keyhole limpet hemocyanin priming had no significant detrimental effect on thresholds without implantation. Thresholds were elevated after implantation across all frequencies tested (2-32 kHz) in primed animals but only at higher frequencies (4-32 kHz) in unprimed controls. In primed animals, dexamethasone treatment significantly reduced threshold shifts at 2 and 8 kHz. Keyhole limpet hemocyanin led to the more frequent observation of lymphocytes in the tissue response to the implant. Systemic immune activation at the time of cochlear implantation broadened the range of frequencies experiencing elevated thresholds after implantation. Local dexamethasone provides partial protection against this hearing loss, but the degree and extent of protection are less compared to previous studies with unprimed animals.

  2. Variation analysis of transcriptome changes reveals cochlear genes and their associated functions in cochlear susceptibility to acoustic overstimulation.

    PubMed

    Yang, Shuzhi; Cai, Qunfeng; Bard, Jonathan; Jamison, Jennifer; Wang, Jianmin; Yang, Weiping; Hu, Bo Hua

    2015-12-01

    Individual variation in the susceptibility of the auditory system to acoustic overstimulation has been well-documented at both the functional and structural levels. However, the molecular mechanism responsible for this variation is unclear. The current investigation was designed to examine the variation patterns of cochlear gene expression using RNA-seq data and to identify the genes with expression variation that increased following acoustic trauma. This study revealed that the constitutive expressions of cochlear genes displayed diverse levels of gene-specific variation. These variation patterns were altered by acoustic trauma; approximately one-third of the examined genes displayed marked increases in their expression variation. Bioinformatics analyses revealed that the genes that exhibited increased variation were functionally related to cell death, biomolecule metabolism, and membrane function. In contrast, the stable genes were primarily related to basic cellular processes, including protein and macromolecular syntheses and transport. There was no functional overlap between the stable and variable genes. Importantly, we demonstrated that glutamate metabolism is related to the variation in the functional response of the cochlea to acoustic overstimulation. Taken together, the results indicate that our analyses of the individual variations in transcriptome changes of cochlear genes provide important information for the identification of genes that potentially contribute to the generation of individual variation in cochlear responses to acoustic overstimulation. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Cochlear Implants (For Parents)

    MedlinePlus

    ... nerve, and send it to the brain. The cochlear implant package is made up of: a receiver-stimulator that contains all of the electronic circuits that control the flow of electrical pulses into the ear an antenna ...

  4. The cochlear size of bats and rodents derived from MRI images and histology.

    PubMed

    Hsiao, Chun Jen; Jen, Philip Hung-Sun; Wu, Chung Hsin

    2015-05-27

    From the evolutionary perspective, the ear of each animal species is built for effective processing of the biologically relevant signals used for communication and acoustically guided orientation. Because the sound pulses used by echolocating bats for orientation and rodents for communication are quite different, the basic design of the mammalian auditory system commonly shared by echolocating bats must be specialized in some manner to effectively process their species-specific sounds. The present study examines the difference in the cochlea of these animal species using MRI images and histological techniques. We report here that, although all these animal species share a similar cochlear structure, they vary in their cochlear size and turns. Bats using constant frequency-frequency-modulated pulses (CF-FM bats) and frequency-modulated pulses (FM bats) for echolocation have a larger cochlear size and more cochlear turns than rodents (mice and rats). However, CF-FM bats have the largest cochlear size and most cochlear turns. This difference in cochlear size and turns of these animal species is discussed in relation to their biologically relevant sounds and acoustic behavior.

  5. A software tool for analyzing multichannel cochlear implant signals.

    PubMed

    Lai, Wai Kong; Bögli, Hans; Dillier, Norbert

    2003-10-01

    A useful and convenient means to analyze the radio frequency (RF) signals being sent by a speech processor to a cochlear implant would be to actually capture and display them with appropriate software. This is particularly useful for development or diagnostic purposes. sCILab (Swiss Cochlear Implant Laboratory) is such a PC-based software tool intended for the Nucleus family of Multichannel Cochlear Implants. Its graphical user interface provides a convenient and intuitive means for visualizing and analyzing the signals encoding speech information. Both numerical and graphic displays are available for detailed examination of the captured CI signals, as well as an acoustic simulation of these CI signals. sCILab has been used in the design and verification of new speech coding strategies, and has also been applied as an analytical tool in studies of how different parameter settings of existing speech coding strategies affect speech perception. As a diagnostic tool, it is also useful for troubleshooting problems with the external equipment of the cochlear implant systems.

  6. Congenitally deafblind children and cochlear implants: effects on communication.

    PubMed

    Dammeyer, Jesper

    2009-01-01

    There has been much research conducted demonstrating the positive benefits of cochlear implantation (CI) in children who are deaf. Research on CI in children who are both deaf and blind, however, is lacking. The purpose of this article is to present a study of five congenitally deafblind children who received cochlear implants between 2.2 and 4.2 years of age. Ratings of video observations were used to measure the children's early communication development with and without the use of their cochlear implants. In addition, parental interviews were used to assess the benefits parents perceived regarding their children's cochlear implants. Two examples are included in this article to illustrate the parents' perspectives about CI in their deafblind children. Benefits of CI in this cohort of children included improved attention and emotional response as well as greater use of objects in interaction with adults. The best overall outcome of CI is not spoken language but better communication.

  7. Libyan cochlear implant programme: achievements, difficulties, and future goals

    PubMed Central

    Salamat, Ali; Esriti, Anwer; Ehtuish, Asia; El-Ogbi, Samya

    2011-01-01

    Cochlear implantation has become established worldwide as a safe and effective method of auditory rehabilitation of selected severely and profound deaf children and adults. Over 100,000 patients have received cochlear implants worldwide with the paediatric population proving to be the main beneficiaries. The Libyan cochlear implant programme was set up in 2004. Data relating to the patients who received cochlear implantation at Tripoli Medical Centre between October 2007 and February 2010 were analysed. Implant operations were performed on 37 patients. All patients received Med-El SONATATI100 devices. Thirty-four (91.9%) of these patients were children, whilst three (8.1%) were adults. Combined, congenital hearing loss (56.8%) and perinatal/neonatal (29.7%) were the two main aetiological factors in children. Seventeen patients (45.9%) had a positive family history of deafness. Sixteen patients (43.2%) were born to blood-related parents. The overall rate of minor and major complications was 16.2%, which is comparable to previous studies. PMID:21694783

  8. Libyan cochlear implant programme: achievements, difficulties, and future goals.

    PubMed

    Salamat, Ali; Esriti, Anwer; Ehtuish, Asia; El-Ogbi, Samya

    2011-01-01

    Cochlear implantation has become established worldwide as a safe and effective method of auditory rehabilitation of selected severely and profound deaf children and adults. Over 100,000 patients have received cochlear implants worldwide with the paediatric population proving to be the main beneficiaries. The Libyan cochlear implant programme was set up in 2004. Data relating to the patients who received cochlear implantation at Tripoli Medical Centre between October 2007 and February 2010 were analysed. Implant operations were performed on 37 patients. All patients received Med-El SONATA(TI) (100) devices. Thirty-four (91.9%) of these patients were children, whilst three (8.1%) were adults. Combined, congenital hearing loss (56.8%) and perinatal/neonatal (29.7%) were the two main aetiological factors in children. Seventeen patients (45.9%) had a positive family history of deafness. Sixteen patients (43.2%) were born to blood-related parents. The overall rate of minor and major complications was 16.2%, which is comparable to previous studies.

  9. Tinnitus and Sleep Difficulties After Cochlear Implantation.

    PubMed

    Pierzycki, Robert H; Edmondson-Jones, Mark; Dawes, Piers; Munro, Kevin J; Moore, David R; Kitterick, Pádraig T

    To estimate and compare the prevalence of and associations between tinnitus and sleep difficulties in a sample of UK adult cochlear implant users and those identified as potential candidates for cochlear implantation. The study was conducted using the UK Biobank resource, a population-based cohort of 40- to 69-year olds. Self-report data on hearing, tinnitus, sleep difficulties, and demographic variables were collected from cochlear implant users (n = 194) and individuals identified as potential candidates for cochlear implantation (n = 211). These "candidates" were selected based on (i) impaired hearing sensitivity, inferred from self-reported hearing aid use and (ii) impaired hearing function, inferred from an inability to report words accurately at negative signal to noise ratios on an unaided closed-set test of speech perception. Data on tinnitus (presence, persistence, and related distress) and on sleep difficulties were analyzed using logistic regression models controlling for gender, age, deprivation, and neuroticism. The prevalence of tinnitus was similar among implant users (50%) and candidates (52%; p = 0.39). However, implant users were less likely to report that their tinnitus was distressing at its worst (41%) compared with candidates (63%; p = 0.02). The logistic regression model suggested that this difference between the two groups could be explained by the fact that tinnitus was less persistent in implant users (46%) compared with candidates (72%; p < 0.001). Self-reported difficulties with sleep were similar among implant users (75%) and candidates (82%; p = 0.28), but participants with tinnitus were more likely to report sleep difficulties than those without (p < 0.001). The prevalence of sleep difficulties was not related to tinnitus persistence (p = 0.28) or the extent to which tinnitus was distressing (p = 0.55). The lack of association between tinnitus persistence and sleep difficulties is compatible with the notion that tinnitus is suppressed

  10. Microphone directionality, pre-emphasis filter, and wind noise in cochlear implants.

    PubMed

    Chung, King; McKibben, Nicholas

    2011-10-01

    Wind noise can be a nuisance or a debilitating masker for cochlear implant users in outdoor environments. Previous studies indicated that wind noise at the microphone/hearing aid output had high levels of low-frequency energy and the amount of noise generated is related to the microphone directionality. Currently, cochlear implants only offer either directional microphones or omnidirectional microphones for users at-large. As all cochlear implants utilize pre-emphasis filters to reduce low-frequency energy before the signal is encoded, effective wind noise reduction algorithms for hearing aids might not be applicable for cochlear implants. The purposes of this study were to investigate the effect of microphone directionality on speech recognition and perceived sound quality of cochlear implant users in wind noise and to derive effective wind noise reduction strategies for cochlear implants. A repeated-measure design was used to examine the effects of spectral and temporal masking created by wind noise recorded through directional and omnidirectional microphones and the effects of pre-emphasis filters on cochlear implant performance. A digital hearing aid was programmed to have linear amplification and relatively flat in-situ frequency responses for the directional and omnidirectional modes. The hearing aid output was then recorded from 0 to 360° at flow velocities of 4.5 and 13.5 m/sec in a quiet wind tunnel. Sixteen postlingually deafened adult cochlear implant listeners who reported to be able to communicate on the phone with friends and family without text messages participated in the study. Cochlear implant users listened to speech in wind noise recorded at locations that the directional and omnidirectional microphones yielded the lowest noise levels. Cochlear implant listeners repeated the sentences and rated the sound quality of the testing materials. Spectral and temporal characteristics of flow noise, as well as speech and/or noise characteristics before

  11. Exploring the Language and Literacy Outcomes of Pediatric Cochlear Implant Users

    PubMed Central

    Spencer, Linda J.; Barker, Brittan A.; Tomblin, J. Bruce

    2011-01-01

    Objective The principal goal of this study was to investigate the relationship between language and literacy (i.e., reading and writing) skills in pediatric cochlear implant users. A peripheral objective was to identify the children's skills that were in need of remediation and subsequently to provide suggestions for remedial programming. It was predicted that the robust language skills often associated with children who have cochlear implant experience would facilitate the development of literacy skills. It was further proposed that the language and literacy skills of pediatric cochlear implant users would approximate the language and literacy skills of children with normal hearing. Design Sixteen pediatric cochlear implant users' language and literacy skills were evaluated and then compared with a reference group of 16 age-matched, normal-hearing children. All 32 participants were educated in mainstream classes within the public school system in the Midwest. The “Sentence Formulation” and “Concepts and Directions” subtests of the Clinical Evaluation of Language Fundamentals-3 test were used to evaluate receptive and expressive language skills. Reading comprehension was evaluated with the “Paragraph Comprehension” subtest of the Woodcock Reading Mastery Test. Performance measures for the writing analyses included productivity, complexity and grammaticality measures. Results Children with cochlear implants performed within 1 SD of the normal-hearing, age-matched children on measures of language comprehension, reading comprehension and writing accuracy. However, the children with cochlear implants performed significantly poorer than the children with normal hearing on the expressive “Sentence Formulation” subtest. The cochlear implant users also produced fewer words on the written narrative task than did the normal-hearing children, although there was not a significant difference between groups with respect to total words per clause. Furthermore

  12. Effects of platelet-rich fibrin on healing of intra-bony defects treated with anorganic bovine bone mineral.

    PubMed

    Sezgin, Yasemin; Uraz, Ahu; Taner, I Levent; Çulhaoğlu, Rana

    2017-01-26

    Anorganic bovine bone mineral (ABBM) is extensively used in the treatment of intra-bony defects. Platelet-rich fibrin (PRF) is a new-generation platelet concentrate with a simplified technique. Although certain studies have reported the use of PRF in the treatment of intra-bony defects, to date, none of them have evaluated its additive effects with ABBM. Therefore, a randomised, split-mouth clinical trial was conducted to compare healing of intra-bony defects treated with an ABBM-PRF combination with healing of those treated with ABBM alone. By using a split-mouth design, 15 paired intra-bony defects were randomly treated with either ABBM alone (control group) or ABBM-PRF combination (test group). Following clinical parameters and radiographical measurements were recorded at baseline and 6 months after treatment: plaque index (PI), gingival index (GI), probing depth (PD), gingival recession (GR), clinical attachment level (CAL), vertical bone loss, depth of defect and defect angle. Preoperative clinical and radiographical measurements were similar for the test and control groups. Statistically significant reductions in GI, PD, CAL, vertical bone loss, depth of intra-bony defect and widening of defect angle were detected after treatment in both groups. With respect to inter-group analysis, gain in CAL was significantly greater in the test group than in the control group, whereas no inter-group differences were observed in any other parameter. The results of this study indicate that both therapies are effective in the treatment of intra-bony defects.

  13. CAT & MAUS: A novel system for true dynamic motion measurement of underlying bony structures with compensation for soft tissue movement.

    PubMed

    Jia, Rui; Monk, Paul; Murray, David; Noble, J Alison; Mellon, Stephen

    2017-09-06

    Optoelectronic motion capture systems are widely employed to measure the movement of human joints. However, there can be a significant discrepancy between the data obtained by a motion capture system (MCS) and the actual movement of underlying bony structures, which is attributed to soft tissue artefact. In this paper, a computer-aided tracking and motion analysis with ultrasound (CAT & MAUS) system with an augmented globally optimal registration algorithm is presented to dynamically track the underlying bony structure during movement. The augmented registration part of CAT & MAUS was validated with a high system accuracy of 80%. The Euclidean distance between the marker-based bony landmark and the bony landmark tracked by CAT & MAUS was calculated to quantify the measurement error of an MCS caused by soft tissue artefact during movement. The average Euclidean distance between the target bony landmark measured by each of the CAT & MAUS system and the MCS alone varied from 8.32mm to 16.87mm in gait. This indicates the discrepancy between the MCS measured bony landmark and the actual underlying bony landmark. Moreover, Procrustes analysis was applied to demonstrate that CAT & MAUS reduces the deformation of the body segment shape modeled by markers during motion. The augmented CAT & MAUS system shows its potential to dynamically detect and locate actual underlying bony landmarks, which reduces the MCS measurement error caused by soft tissue artefact during movement. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Scanning Electrochemical Microscopy as a Novel Proximity Sensor for Atraumatic Cochlear Implant Insertion

    PubMed Central

    Velmurugan, J.; Mirkin, M. V.; Svirsky, M. A.; Lalwani, A. K.; Llinas, R. R.

    2014-01-01

    A growing number of minimally invasive surgical and diagnostic procedures require the insertion of an optical, mechanical, or electronic device in narrow spaces inside a human body. In such procedures, precise motion control is essential to avoid damage to the patient’s tissues and/or the device itself. A typical example is the insertion of a cochlear implant which should ideally be done with minimum physical contact between the moving device and the cochlear canal walls or the basilar membrane. Because optical monitoring is not possible, alternative techniques for sub millimeter-scale distance control can be very useful for such procedures. The first requirement for distance control is distance sensing. We developed a novel approach to distance sensing based on the principles of scanning electrochemical microscopy (SECM). The SECM signal, i.e., the diffusion current to a microelectrode, is very sensitive to the distance between the probe surface and any electrically insulating object present in its proximity. With several amperometric microprobes fabricated on the surface of an insertable device, one can monitor the distances between different parts of the moving implant and the surrounding tissues. Unlike typical SECM experiments, in which a disk-shaped tip approaches a relatively smooth sample, complex geometries of the mobile device and its surroundings make distance sensing challenging. Additional issues include the possibility of electrode surface contamination in biological fluids and the requirement for a biologically compatible redox mediator. PMID:24845292

  15. Cochlear implantation in autistic children with profound sensorineural hearing loss.

    PubMed

    Lachowska, Magdalena; Pastuszka, Agnieszka; Łukaszewicz-Moszyńska, Zuzanna; Mikołajewska, Lidia; Niemczyk, Kazimierz

    2016-11-19

    Cochlear implants have become the method of choice for the treatment of severe-to-profound hearing loss in both children and adults. Its benefits are well documented in the pediatric and adult population. Also deaf children with additional needs, including autism, have been covered by this treatment. The aim of this study was to assess the benefits from cochlear implantation in deafened children with autism as the only additional disability. This study analyzes data of six children. The follow-up time was at least 43 months. The following data were analyzed: medical history, reaction to music and sound, Ling's six sounds test, onomatopoeic word test, reaction to spoken child's name, response to requests, questionnaire given to parents, sound processor fitting sessions and data. After cochlear implantation each child presented other communication skills. In some children, the symptoms of speech understanding were observed. No increased hyperactivity associated with daily use cochlear implant was observed. The study showed that in autistic children the perception is very important for a child's sense of security and makes contact with parents easier. Our study showed that oral communication is not likely to be a realistic goal in children with cochlear implants and autism. The implantation results showed benefits that varied among those children. The traditional methods of evaluating the results of cochlear implantation in children with autism are usually insufficient to fully assess the functional benefits. These benefits should be assessed in a more comprehensive manner taking into account the limitations of communication resulting from the essence of autism. It is important that we share knowledge about these complex children with cochlear implants. Copyright © 2016 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  16. [Applied anatomy of scala tympani inlet related to cochlear implantation].

    PubMed

    Zou, Tuanming; Guo, Menghe; Zhang, Hongzheng; Shu, Fan; Xie, Nanping

    2012-06-01

    To investigate the related parameters of the temporal bone structure for determining the position of implanting electrode into the scala tympani in cochlear implantation surgery through the facial recess and epitympanum approach. In a surgical simulation experiment, 20 human temporal bones were studied and measured to determine the related parameters of the temporal bone structure. The distance 5.91∓0.29 mm between the short process of the incus and the round window niche, 2.11∓0.18 mm between the stapes and the round window niche, 6.70∓0.19 mm between the facial nerve in the perpendicular paragraph and the round window niche, 2.22∓0.21 mm from the pyramidal eminence to the round window, and 2.16∓0.14 mm between the stapes and the round window. The minimal distance between the implanting electrode and the vestibular window was 2.12∓0.19 mm. The distance between the cochleariform process and the round window niche was 3.79∓0.17 mm. The position of the cochlear electrode array insertion into the second cochlear turn was 2.25∓0.13 mm under the stapes. The location of the cochlear electrode array insertion into the second cochlear turn was 2.28∓0.20 mm inferior to the pyramidal eminence. These parameters provide a reference value to determine the different positions of cochlear electrode array insertion into the scale tympani in different patients.

  17. [Cost Analysis of Cochlear Implantation in Adults].

    PubMed

    Raths, S; Lenarz, T; Lesinski-Schiedat, A; Flessa, S

    2016-04-01

    The number of implantation of cochlear implants has steadily risen in recent years. Reasons for this are an extension of indication criteria, demographic change, increased quality of life needs and greater acceptance. The consequences are rising expenditure for statutory health insurance (SHI) for cochlear implantation. A detailed calculation of lifetime costs from SHI's perspective for postlingually deafened adolescents and adults is essential in estimating future cost developments. Calculations are based on accounting data from the Hannover Medical School. With regard to further life expectancy, average costs of preoperative diagnosis, surgery, rehabilitation, follow-ups, processor upgrades and electrical maintenance were discounted to their present value at age of implantation. There is an inverse relation between cost of unilateral cochlear implantation and age of initial implantation. From SHI's perspective, the intervention costs between 36,001 and 68,970 € ($ 42,504-$ 81,429). The largest cost components are initial implantation and processor upgrades. Compared to the UK the cost of cochlear implantation in Germany seems to be significantly lower. In particular the costs of, rehabilitation and maintenance in Germany cause only a small percentage of total costs. Also, the costs during the first year of treatment seem comparatively low. With regard to future spending of SHI due to implant innovations and associated extension of indication, increasing cost may be suspected. © Georg Thieme Verlag KG Stuttgart · New York.

  18. Cochlear Implantation in Siblings With Refsum's Disease.

    PubMed

    Stähr, Kerstin; Kuechler, Alma; Gencik, Martin; Arnolds, Judith; Dendy, Meaghan; Lang, Stephan; Arweiler-Harbeck, Diana

    2017-08-01

    Whether the origin of severe hearing loss in Refsum's syndrome is caused by cochlear impairment or retrocochlear degeneration remains unclear. This case report aims to investigate hearing performance before and after cochlear implantation to shed light on this question. Also, identification of new mutations causing Refsum's syndrome would be helpful in generating additional means of diagnosis. A family of 4 individuals was subjected to genetic testing. Two siblings (56 and 61 years old) suffered from severe hearing and vision loss and received bilateral cochlear implants. Genetic analysis, audiological outcome, and clinical examinations were performed. One new mutation in the PHYH gene (c.768del63bp) causing Refsum's disease was found. Preoperative distortion product otoacoustic emissions (DPAOEs) were absent. Postoperative speech perception in Freiburger speech test was 100% for bisyllabic words and 85% (patient No. 1) and 65% (patient No. 2), respectively, for monosyllabic words. Five years after implantation, speech perception remained stable for bisyllabic words but showed decreasing capabilities for monosyllabic words. A new mutation causing Refsum's disease is presented. Cochlear implantation in case of severe hearing loss leads to an improvement in speech perception and should be recommended for patients with Refsum's disease, especially when the hearing loss is combined with a severe loss of vision. Decrease of speech perception in the long-term follow-up could indicate an additional retrocochlear degeneration.

  19. Impact of Bony Stress Injuries on Professional Basketball Performance

    PubMed Central

    Khan, Moin; Madden, Kim; Rogowski, Joseph P.; Stotts, Jeff; Burrus, Matthew Tyrrell; Samani, Marisa; Sikka, Robby Singh; Bedi, Asheesh

    2017-01-01

    Objectives: Players in the National Basketball Association (NBA) subject their lower extremities to significant repetitive loading during the season as well as during off-season training. Little is known about the incidence and impact of lower extremity bony stress injuries in these athletes. Methods: Using the player injury database maintained by the NBA Players’ Association, all bony stress injuries from 1992 to May 2016 were identified. Those not involving the lower extremity were excluded from the study. Stress fractures and stress reactions were grouped together. Number of games missed due to the injury as well as player statistics including points per game (ppg), assists per game (apg), steals per game (spg), and blocks per game (bpg) were collected from two years prior to the injury to two years after the injury. Results: 76 lower extremity bony stress injuries were identified involving 75 different NBA players with an average player age of 25.4 ± 4.1 years. 55.3% (42/76) involved the foot, 21.1% (16/76) involved the ankle or fibula, 17.1% (13/76) involved the tibia, and 6.6% (5/76) involved either the knee or patella. The majority of injuries occurred in season 82.9% (63/76) with half of the injuries occurring within the first 6 weeks of the season. 38.2% (29/76) of these injuries were managed surgically. An average of 25.1 ± 21.3 games were missed. 19.7% (15/76) of patients who sustained a stress fracture also had a subsequent injury. 29.2% (21/76) of players were not able to return to professional basketball after the season in which the injury was sustained; however, those who were able to return to the same level of play did not see a significant change in performance as measured by ppg, apg, spg, or bpg when comparing the season prior to the injury and either one or two years after the injury. Stress injuries to the foot carried the worst prognosis, 57.1% (12/21) of those unable to return to professional basketball sustained such an injury

  20. The importance of electrically evoked stapedial reflex in cochlear implant.

    PubMed

    Andrade, Kelly Cristina Lira de; Leal, Mariana de Carvalho; Muniz, Lilian Ferreira; Menezes, Pedro de Lemos; Albuquerque, Katia Maria Gomes de; Carnaúba, Aline Tenório Lins

    2014-01-01

    The most important stage in fitting a cochlear implant is the identification of its dynamic range. The use of objective measures, in particular the electrically elicited stapedius reflex, may provide suitable assistence for initial fitting of cochlear implant, especially in children or adult with multiple disorders, because they provide specific values that serve as the basis of early cochlear implant programming. Verify through a review the use of the electrically elicited stapedius reflex threshold during the activation and mapping process of cochlear implant. Bibliographical search on the Pubmed and Bireme plataforms, and also on Medline, LILACS and SciELO databases, with standard searches until September 2012, using specific keywords. For the selection and evaluation of scientific studies found in the search, criterias have been established, considering the following aspects: author, year/location, grade of recommendation/level of evidence, purpose, sample, age, mean age in years, evaluative testing, results and conclusion. Among 7,304 articles found, 7,080 were excluded from the title, 152 from the abstract, 17 from the article reading, 43 were repeated and 12 were selected for the study. The electrically elicited stapedius reflex may support when programming the cochlear implant, especially in patients with inconsistent responses.

  1. Serving Deaf Students Who Have Cochlear Implants. PEPNet Tipsheet

    ERIC Educational Resources Information Center

    Searls, J. Matt, Comp.

    2010-01-01

    Cochlear implants (CIs) are complex electronic devices surgically implanted under the skin behind the ear. These devices utilize electrodes placed in the inner ear (the cochlea) to stimulate the auditory nerve of individuals with significant permanent hearing loss. Cochlear implants may not be suitable for everyone. They are designed to provide…

  2. The Modified Rambo Transcanal Approach for Cochlear Implantation in CHARGE Syndrome.

    PubMed

    Wick, Cameron C; Moore, Amy M; Killeen, Daniel E; Isaacson, Brandon

    2017-10-01

    CHARGE syndrome is associated with a variety of temporal bone anomalies and deafness. The lack of surgical landmarks and facial nerve irregularities make cochlear implantation in this population a challenging endeavor. This study aims to describe a safe and efficacious transcanal approach for cochlear implantation that obviates the need to perform a mastoidectomy and facial recess. Three children with profound hearing loss secondary to CHARGE syndrome. Transcanal cochlear implantation with closure of the ear canal via a modified Rambo meatoplasty. Retrospective chart review of temporal bone anomalies associated with CHARGE syndrome, technical nuances of this transcanal approach, and cochlear implant outcomes. The mean patient age was 2.5 years (range 1.5-3.8 yr). Two were male and two were left ears. All patients had a hypoplastic mastoid, semicircular canal aplasia, and had some degree of cochlear dysplasia. A full cochlear implant insertion was achieved in all cases, even in the presence of grossly abnormal middle ear and facial nerve anatomy. There were no intraoperative or postoperative complications. The mean follow-up was 12.4 months (range, 3.9-25.2 mo). All three patients use their device daily. Their guardians report improved vocalization and environmental awareness. The modified Rambo transcanal approach provides a safe corridor for cochlear implantation in patients with CHARGE syndrome. This approach minimizes the anatomical variations associated with the syndrome and may reduce the risk of electrode extrusion. Implant outcomes in this patient population remain highly variable based on the patient's global cognitive capacity.

  3. Music Perception of Cochlear Implant Recipients with Implications for Music Instruction: A Review of Literature

    PubMed Central

    Hsiao, Feilin; Gfeller, Kate

    2013-01-01

    This review of literature presents a systematic analysis of the capabilities and limitations of cochlear implant recipients regarding music perception. Specifically, it a) analyzes individual components of music (e.g., rhythm, timbre, and pitch) as they interface with the technical characteristics of cochlear implants and the perceptual abilities of cochlear implant recipients; and b) describes accommodations for music instruction that support successful participation of children with cochlear implants. This article consolidates research studies from various disciplines (audiology, hearing science, speech-language pathology, cochlear implants, and music therapy) to provide practical recommendations for educators in fostering the musical growth of children with cochlear implants. PMID:23469365

  4. Taxonomic Knowledge of Children with and without Cochlear Implants

    ERIC Educational Resources Information Center

    Lund, Emily; Dinsmoor, Jessica

    2016-01-01

    Purpose: The purpose of this study was to compare the taxonomic vocabulary knowledge and organization of children with cochlear implants to (a) children with normal hearing matched for age, and (b) children matched for vocabulary development. Method: Ten children with cochlear implants, 10 age-matched children with normal hearing, and 10…

  5. Comparisons between detection threshold and loudness perception for individual cochlear implant channels

    PubMed Central

    Bierer, Julie Arenberg; Nye, Amberly D

    2014-01-01

    Objective The objective of the present study, performed in cochlear implant listeners, was to examine how the level of current required to detect single-channel electrical pulse trains relates to loudness perception on the same channel. The working hypothesis was that channels with relatively high thresholds, when measured with a focused current pattern, interface poorly to the auditory nerve. For such channels a smaller dynamic range between perceptual threshold and the most comfortable loudness would result, in part, from a greater sensitivity to changes in electrical field spread compared to low-threshold channels. The narrower range of comfortable listening levels may have important implications for speech perception. Design Data were collected from eight, adult cochlear implant listeners implanted with the HiRes90k cochlear implant (Advanced Bionics Corp.). The partial tripolar (pTP) electrode configuration, consisting of one intracochlear active electrode, two flanking electrodes carrying a fraction (σ) of the return current, and an extracochlear ground, was used for stimulation. Single-channel detection thresholds and most comfortable listening levels were acquired using the most focused pTP configuration possible (σ ≥ 0.8) to identify three channels for further testing – those with the highest, median, and lowest thresholds – for each subject. Threshold, equal-loudness contours (at 50% of the monopolar dynamic range), and loudness growth functions were measured for each of these three test channels using various partial tripolar fractions. Results For all test channels, thresholds increased as the electrode configuration became more focused. The rate of increase with the focusing parameter σ was greatest for the high-threshold channel compared to the median- and low-threshold channels. The 50% equal-loudness contours exhibited similar rates of increase in level across test channels and subjects. Additionally, test channels with the highest

  6. Cochlear pathology in chronic suppurative otitis media.

    PubMed

    Walby, A P; Barrera, A; Schuknecht, H F

    1983-01-01

    Chronic suppurative otitis media (COM) is reported to cause elevation of bone-conduction thresholds either by damage to cochlear sensorineural structures or by alteration in the mechanics of sound transmission in the ear. A retrospective study was made of the medical records of 87 patients with unilateral uncomplicated COM to document that abnormality in bone conduction does exist. In a separate study the cochlear pathology in 12 pairs of temporal bones with unilateral COM was studied by light microscopy. Infected ears showed higher than normal mean bone-conduction thresholds by amounts ranging from 1 dB at 500 Hz to 9.5 dB at 4,000 Hz. The temporal bones showed no greater loss of specialized sensorineural structures in infected ears than in normal control ears. Because there is no evidence that COM caused destruction of hair cells or cochlear neurons, alteration in the mechanics of sound transmission becomes a more plausible explanation for the hearing losses.

  7. First Record of Eocene Bony Fishes and Crocodyliforms from Canada’s Western Arctic

    PubMed Central

    Eberle, Jaelyn J.; Gottfried, Michael D.; Hutchison, J. Howard; Brochu, Christopher A.

    2014-01-01

    Background Discovery of Eocene non-marine vertebrates, including crocodylians, turtles, bony fishes, and mammals in Canada’s High Arctic was a critical paleontological contribution of the last century because it indicated that this region of the Arctic had been mild, temperate, and ice-free during the early – middle Eocene (∼53–50 Ma), despite being well above the Arctic Circle. To date, these discoveries have been restricted to Canada’s easternmost Arctic – Ellesmere and Axel Heiberg Islands (Nunavut). Although temporally correlative strata crop out over 1,000 km west, on Canada’s westernmost Arctic Island – Banks Island, Northwest Territories – they have been interpreted as predominantly marine. We document the first Eocene bony fish and crocodyliform fossils from Banks Island. Principal Findings We describe fossils of bony fishes, including lepisosteid (Atractosteus), esocid (pike), and amiid, and a crocodyliform, from lower – middle Eocene strata of the Cyclic Member, Eureka Sound Formation within Aulavik National Park (∼76°N. paleolat.). Palynology suggests the sediments are late early to middle Eocene in age, and likely spanned the Early Eocene Climatic Optimum (EECO). Conclusions/Significance These fossils extend the geographic range of Eocene Arctic lepisosteids, esocids, amiids, and crocodyliforms west by approximately 40° of longitude or ∼1100 km. The low diversity bony fish fauna, at least at the family level, is essentially identical on Ellesmere and Banks Islands, suggesting a pan-High Arctic bony fish fauna of relatively basal groups around the margin of the Eocene Arctic Ocean. From a paleoclimatic perspective, presence of a crocodyliform, gar and amiid fishes on northern Banks provides further evidence that mild, year-round temperatures extended across the Canadian Arctic during early – middle Eocene time. Additionally, the Banks Island crocodyliform is consistent with the phylogenetic hypothesis of a Paleogene divergence

  8. Cochlear blood flow and speech perception ability in cochlear implant users.

    PubMed

    Nakashima, Tsutomu; Hattori, Taku; Sone, Michihiko; Asahi, Kiyomitsu; Matsuda, Naoko; Teranishi, Masaaki; Yoshida, Tadao; Kato, Ken; Sato, Eisuke

    2012-02-01

    The effect of cochlear blood flow (CBF) on speech perception ability in cochlear implant (CI) users has not been reported. We investigated various factors influencing speech perception including CBF in CI users. Eighty-two patients who received CI surgery at an academic hospital. CBF was measured during CI surgery using laser Doppler flowmetry. The speech perception level was measured after a sufficient interval after CI surgery. Multivariate analysis was used to evaluate the influences of age, duration of deafness, sex, cause of deafness, and CBF on the speech perception level. CBF decreased significantly with age but was not related to the speech perception level. In patients with congenital hearing loss, the speech perception level was significantly worse in children who received a CI at 3 years of age than in those who received a CI at 2 years of age or younger. Duration of deafness before CI surgery had deteriorative effects on the speech perception level. CBF may be associated with progression of hearing loss. However, measuring CBF during CI surgery is not useful for predicting postoperative speech perception.

  9. Auditory Cortex Basal Activity Modulates Cochlear Responses in Chinchillas

    PubMed Central

    León, Alex; Elgueda, Diego; Silva, María A.; Hamamé, Carlos M.; Delano, Paul H.

    2012-01-01

    Background The auditory efferent system has unique neuroanatomical pathways that connect the cerebral cortex with sensory receptor cells. Pyramidal neurons located in layers V and VI of the primary auditory cortex constitute descending projections to the thalamus, inferior colliculus, and even directly to the superior olivary complex and to the cochlear nucleus. Efferent pathways are connected to the cochlear receptor by the olivocochlear system, which innervates outer hair cells and auditory nerve fibers. The functional role of the cortico-olivocochlear efferent system remains debated. We hypothesized that auditory cortex basal activity modulates cochlear and auditory-nerve afferent responses through the efferent system. Methodology/Principal Findings Cochlear microphonics (CM), auditory-nerve compound action potentials (CAP) and auditory cortex evoked potentials (ACEP) were recorded in twenty anesthetized chinchillas, before, during and after auditory cortex deactivation by two methods: lidocaine microinjections or cortical cooling with cryoloops. Auditory cortex deactivation induced a transient reduction in ACEP amplitudes in fifteen animals (deactivation experiments) and a permanent reduction in five chinchillas (lesion experiments). We found significant changes in the amplitude of CM in both types of experiments, being the most common effect a CM decrease found in fifteen animals. Concomitantly to CM amplitude changes, we found CAP increases in seven chinchillas and CAP reductions in thirteen animals. Although ACEP amplitudes were completely recovered after ninety minutes in deactivation experiments, only partial recovery was observed in the magnitudes of cochlear responses. Conclusions/Significance These results show that blocking ongoing auditory cortex activity modulates CM and CAP responses, demonstrating that cortico-olivocochlear circuits regulate auditory nerve and cochlear responses through a basal efferent tone. The diversity of the obtained effects

  10. Noise alters hair-bundle mechanics at the cochlear apex

    NASA Astrophysics Data System (ADS)

    Strimbu, C. Elliott; Fridberger, Anders

    2015-12-01

    Exposure to loud sounds can lead to both permanent and short term changes in auditory sensitivity. Permanent hearing loss is often associated with gross changes in cochlear morphology including the loss of hair cells and auditory nerve fibers while the mechanisms of short term threshold shifts are much less well understood and may vary at different locations across the cochlea. Previous reports suggest that exposure to loud sounds leads to a decrease in the cochlear microphonic potential and in the stiffness of the organ of Corti. Because the cochlear microphonic reflects changes in the membrane potential of the hair cells, this suggests that hair-bundle motion should be reversibly altered following exposure to loud sounds. Using an in vitro preparation of the guinea pig temporal bone we investigate changes in the micro-mechanical response near the cochlear apex following a brief (up to 10 - 20 minutes) exposure to loud (˜ 120 dB) tones near the best frequency at this location. We use time-resolved confocal imaging to record the motion of outer hair cell bundles before and after acoustic overstimulation. We have also recorded larger-scale structural views of the organ of Corti before and after exposure to the loud sound. Conventional electrophysiological techniques are used measure the cochlear microphonic potential. As has been previously reported, following acoustic overexposure the cochlear microphonic declines in value and typically recovers on the order of 30 - 60 minutes. Hair-bundle trajectories are affected following the loud sound and typically recover on a somewhat faster time scale than the microphonic potential, although the results vary considerably across preparations. Preliminary results also suggest reversible changes in the hair cell's resting potential following the loud sound.

  11. Emotion Understanding in Deaf Children with a Cochlear Implant

    ERIC Educational Resources Information Center

    Wiefferink, Carin H.; Rieffe, Carolien; Ketelaar, Lizet; De Raeve, Leo; Frijns, Johan H. M.

    2013-01-01

    It is still largely unknown how receiving a cochlear implant affects the emotion understanding in deaf children. We examined indices for emotion understanding and their associations with communication skills in children aged 2.5-5 years, both hearing children (n = 52) and deaf children with a cochlear implant (n = 57). 2 aspects of emotion…

  12. Relationships among Professionals' Knowledge, Experience, and Expectations Regarding Cochlear Implants

    ERIC Educational Resources Information Center

    Ben-Itzhak, D.; Most, T.; Weisel, A.

    2005-01-01

    The present study examined the relationships between teachers' and communication clinicians' self-reported knowledge on cochlear implants and their expectations of CIs. The authors also explored these professionals' views regarding the child's communication mode, educational setting, and social options following cochlear implantation. The…

  13. Should children who use cochlear implants wear hearing aids in the opposite ear?

    PubMed

    Ching, T Y; Psarros, C; Hill, M; Dillon, H; Incerti, P

    2001-10-01

    The aim of this study was to investigate 1) whether a hearing aid needs to be adjusted differently depending on whether a child wears a cochlear implant or another hearing aid in the contralateral ear; 2) whether the use of a hearing aid and a cochlear implant in opposite ears leads to binaural interference; and 3) whether the use of a hearing aid and a cochlear implant in opposite ears leads to binaural benefits in speech perception, localization, and communicative functioning in real life. Sixteen children participated in this study. All children used a Nucleus 22 or Nucleus 24 cochlear implant system programmed with the SPEAK strategy in one ear. The hearing aid amplification requirements in the nonimplanted ear of these children were determined using two procedures. A paired comparison technique was used to identify the frequency response that was best for speech intelligibility in quiet, and a loudness balancing technique was used to match the loudness of speech in the ear with a hearing aid to that with a cochlear implant. Eleven of the 16 children participated in the investigation of binaural effects. Performance in speech perception, localization, and communicative functioning was assessed under four aided conditions: cochlear implant with hearing aid as worn, cochlear implant alone, hearing aid alone, and cochlear implant with hearing aid adjusted according to individual requirements. Fifteen of the 16 children whose amplification requirements were determined preferred a hearing aid frequency response that was within +/-6 dB/octave of the NAL-RP prescription. On average, the children required 6 dB more gain than prescribed to balance the loudness of the implanted ear for a speech signal presented at 65 dB SPL. For all 11 children whose performance was evaluated for investigating binaural effects, there was no indication of significantly poorer performance under bilaterally aided conditions compared with unilaterally aided conditions. On average, there were

  14. Auditory Mechanics of the Tectorial Membrane and the Cochlear Spiral

    PubMed Central

    Gavara, Núria; Manoussaki, Daphne; Chadwick, Richard S.

    2012-01-01

    Purpose of review This review is timely and relevant since new experimental and theoretical findings suggest that cochlear mechanics from the nanoscale to the macroscale are affected by mechanical properties of the tectorial membrane and the spiral shape. Recent findings Main tectorial membrane themes covered are i) composition and morphology, ii) nanoscale mechanical interactions with the outer hair cell bundle, iii) macroscale longitudinal coupling, iv) fluid interaction with inner hair cell bundles, v) macroscale dynamics and waves. Main cochlear spiral themes are macroscale low-frequency energy focusing and microscale organ of Corti shear gain. Implications Findings from new experimental and theoretical models reveal exquisite sensitivity of cochlear mechanical performance to tectorial membrane structural organization, mechanics, and its positioning with respect to hair bundles. The cochlear spiral geometry is a major determinant of low frequency hearing. Suggestions are made for future research directions. PMID:21785353

  15. [Pre-operation evaluation and intra-operation management of cochlear implantation].

    PubMed

    Zhang, Dao-xing; Hu, Bao-hua; Xiao, Yu-li; Shi, Bo-ning

    2004-10-01

    To summarize pre-operation evaluation experiences in cochlear implantation. Performing auditory evaluation and image analysis seriously in 158 severe hearing loss or total deaf cases before cochlear implantation, comparing their performance with the findings during and post operation. Among the total 158 cases, 116 cases with normal structure, 42 cases with the abnormal findings of the inner or middle ear. Stapedial gusher happened in 6 cases, 1 case was not predicted before operation. Except 1 case with serious malformation, the findings of other 157 cases in operation were consistent with the pre-operation evaluation. We helped all patients reconstruct auditory conduction with cochlear implantation, and the average hearing level up to 37.6 dB SPL. Performing image analysis seriously before operation and planning for operation according to HRCT can do great help to cochlear implantation. The operation under the HRCT instruction has less complications.

  16. Round-window delivery of neurotrophin 3 regenerates cochlear synapses after acoustic overexposure.

    PubMed

    Suzuki, Jun; Corfas, Gabriel; Liberman, M Charles

    2016-04-25

    In acquired sensorineural hearing loss, such as that produced by noise or aging, there can be massive loss of the synaptic connections between cochlear sensory cells and primary sensory neurons, without loss of the sensory cells themselves. Because the cell bodies and central projections of these cochlear neurons survive for months to years, there is a long therapeutic window in which to re-establish functional connections and improve hearing ability. Here we show in noise-exposed mice that local delivery of neurotrophin-3 (NT-3) to the round window niche, 24 hours after an exposure that causes an immediate loss of up to 50% loss of synapses in the cochlear basal region, can regenerate pre- and post-synaptic elements at the hair cell / cochlear nerve interface. This synaptic regeneration, as documented by confocal microscopy of immunostained cochlear sensory epithelia, was coupled with a corresponding functional recovery, as seen in the suprathreshold amplitude of auditory brainstem response Wave 1. Cochlear delivery of neurotrophins in humans is likely achievable as an office procedure via transtympanic injection, making our results highly significant in a translational context.

  17. PROPOSED DIAGNOSTIC CRITERIA FOR PROLIFERATIVE THYROID LESIONS IN BONY FISHES

    EPA Science Inventory

    Distinguishing hyperplastic lesions from neoplasia in the thyroid of bony fishes has been debated by scientists for about one hundred years. As early as the first decade of the last century, the histological interpretation of some of the striking proliferative lesions observed in...

  18. DIAGNOSTIC CRITERIA FOR PROLIFERATIVE THYROID LESIONS IN BONY FISHES II

    EPA Science Inventory

    Thyroid proliferative lesions are rather common in bony fishes but diagnostic terminology and criteria for these lesions are inconsistent in the literature. The diagnosis of proliferative thyroid lesions is especially challenging in fish due to the fact that the thyroid is not a ...

  19. Music Therapy for Preschool Cochlear Implant Recipients

    PubMed Central

    Gfeller, Kate; Driscoll, Virginia; Kenworthy, Maura; Van Voorst, Tanya

    2010-01-01

    This paper provides research and clinical information relevant to music therapy for preschool children who use cochlear implants (CI). It consolidates information from various disciplinary sources regarding (a) cochlear implantation of young prelingually-deaf children (~age 2-5), (b) patterns of auditory and speech-language development, and (c) research regarding music perception of children with CIs. This information serves as a foundation for the final portion of the article, which describes typical music therapy goals and examples of interventions suitable for preschool children. PMID:23904691

  20. Ion flow in cochlear hair cells and the regulation of hearing sensitivity.

    PubMed

    Patuzzi, Robert

    2011-10-01

    This paper discusses how ion transport proteins in the hair cells of the mammalian cochlea work to produce a sensitive but stable hearing organ. The transport proteins in the inner and outer hair cells are summarized (including their current voltage characteristics), and the roles of these proteins in determining intracellular Ca(2+), membrane potential, and ultimately cochlear sensitivity are discussed. The paper also discusses the role of the Ca(2+) sequestration sacs in outer hair cells in the autoregulation of hair cell membrane potential and cochlear gain, and how the underdamped control of Ca(2+) within these sacs may produce the observed slow oscillations in cochlear sensitivity and otoacoustic emissions after cochlear perturbations, including perilymphatic perfusions and prolonged low-frequency tones. The relative insensitivity of cochlear gain to short-term changes in the endocochlear potential is also discussed. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Imaging cochlear soft tissue displacement with coherent x-rays

    NASA Astrophysics Data System (ADS)

    Rau, Christoph; Richter, Claus-Peter

    2015-10-01

    At present, imaging of cochlear mechanics at mid-cochlear turns has not been accomplished. Although challenging, this appears possible with partially coherent hard x-rays. The present study shows results from stroboscopic x-ray imaging of a test object at audio frequencies. The vibration amplitudes were quantified. In a different set of experiments, an intact and calcified gerbil temporal bone was used to determine displacements of the reticular lamina, tectorial membrane, and Reissner’s membrane with the Lucas and Kanade video flow algorithm. The experiments validated high frequency x-ray imaging and imaging in a calcified cochlea. The present work is key for future imaging of cochlear micromechanics at a high spatial resolution.

  2. Effects of residual hearing on cochlear implant outcomes in children: A systematic-review.

    PubMed

    Chiossi, Julia Santos Costa; Hyppolito, Miguel Angelo

    2017-09-01

    to investigate if preoperative residual hearing in prelingually deafened children can interfere on cochlear implant indication and outcomes. a systematic-review was conducted in five international databases up to November-2016, to locate articles that evaluated cochlear implantation in children with some degree of preoperative residual hearing. Outcomes were auditory, language and cognition performances after cochlear implant. The quality of the studies was assessed and classified according to the Oxford Levels of Evidence table - 2011. Risk of biases were also described. From the 30 articles reviewed, two types of questions were identified: (a) what are the benefits of cochlear implantation in children with residual hearing? (b) is the preoperative residual hearing a predictor of cochlear implant outcome? Studies ranged from 04 to 188 subjects, evaluating populations between 1.8 and 10.3 years old. The definition of residual hearing varied between studies. The majority of articles (n = 22) evaluated speech perception as the outcome and 14 also assessed language and speech production. There is evidence that cochlear implant is beneficial to children with residual hearing. Preoperative residual hearing seems to be valuable to predict speech perception outcomes after cochlear implantation, even though the mechanism of how it happens is not clear. More extensive researches must be conducted in order to make recommendations and to set prognosis for cochlear implants based on children preoperative residual hearing. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Management of segmental bony defects: the role of osteoconductive orthobiologics.

    PubMed

    McKee, Michael D

    2006-01-01

    Our knowledge about, and the availability of, orthobiologic materials has increased exponentially in the last decade. Although previously confined to the experimental or animal-model realm, several orthobiologics have been shown to be useful in a variety of clinical situations. As surgical techniques in vascular anastomosis, soft-tissue coverage, limb salvage, and fracture stabilization have improved, the size and frequency of bony defects (commensurate with the severity of the initial injury) have increased, as well. Because all methods of managing segmental bony defects have drawbacks, a need remains for a readily available, void-filling, inexpensive bone substitute. Such a bone substitute fulfills a permissive role in allowing new bone to grow into a given defect. Such potential osteoconductive materials include ceramics, calcium sulfate or calcium phosphate compounds, hydroxyapatite, deproteinized bone, corals, and recently developed polymers. Some materials that have osteoinductive properties, such as demineralized bone matrix, also display prominent osteoconductive properties.

  4. Visualization and contractile activity of cochlear pericytes in the capillaries of the spiral ligament.

    PubMed

    Dai, Min; Nuttall, Alfred; Yang, Yue; Shi, Xiaorui

    2009-08-01

    Pericytes, mural cells located on microvessels, are considered to play an important role in the formation of the vasculature and the regulation of local blood flow in some organs. Little is known about the physiology of cochlear pericytes. In order to investigate the function of cochlear pericytes, we developed a method to visualize cochlear pericytes using diaminofluorescein-2 diacetate (DAF-2DA) and intravital fluorescence microscopy. This method can permit the study of the effect of vasoactive agents on pericytes under the in vivo and normal physiological condition. The specificity of the labeling method was verified by the immunofluorescence labeling of pericyte maker proteins such as desmin, neural proteoglycan (NG2), and thymocyte differentiation antigen 1 (Thy-1). Superfused K(+) and Ca(2+) to the cochlear lateral wall resulted in localized constriction of capillaries at pericyte locations both in vivo and in vitro, while there was no obvious change in cochlear capillary diameters with application of the adrenergic neurotransmitter noradrenaline. The method could be an effective way to visualize cochlear pericytes and microvessels and study lateral wall vascular physiology. Moreover, we demonstrate for the first time that cochlear pericytes have contractility, which may be important for regulation of cochlear blood flow.

  5. Improving speech perception in noise for children with cochlear implants.

    PubMed

    Gifford, René H; Olund, Amy P; Dejong, Melissa

    2011-10-01

    Current cochlear implant recipients are achieving increasingly higher levels of speech recognition; however, the presence of background noise continues to significantly degrade speech understanding for even the best performers. Newer generation Nucleus cochlear implant sound processors can be programmed with SmartSound strategies that have been shown to improve speech understanding in noise for adult cochlear implant recipients. The applicability of these strategies for use in children, however, is not fully understood nor widely accepted. To assess speech perception for pediatric cochlear implant recipients in the presence of a realistic restaurant simulation generated by an eight-loudspeaker (R-SPACE™) array in order to determine whether Nucleus sound processor SmartSound strategies yield improved sentence recognition in noise for children who learn language through the implant. Single subject, repeated measures design. Twenty-two experimental subjects with cochlear implants (mean age 11.1 yr) and 25 control subjects with normal hearing (mean age 9.6 yr) participated in this prospective study. Speech reception thresholds (SRT) in semidiffuse restaurant noise originating from an eight-loudspeaker array were assessed with the experimental subjects' everyday program incorporating Adaptive Dynamic Range Optimization (ADRO) as well as with the addition of Autosensitivity control (ASC). Adaptive SRTs with the Hearing In Noise Test (HINT) sentences were obtained for all 22 experimental subjects, and performance-in percent correct-was assessed in a fixed +6 dB SNR (signal-to-noise ratio) for a six-subject subset. Statistical analysis using a repeated-measures analysis of variance (ANOVA) evaluated the effects of the SmartSound setting on the SRT in noise. The primary findings mirrored those reported previously with adult cochlear implant recipients in that the addition of ASC to ADRO significantly improved speech recognition in noise for pediatric cochlear implant

  6. Congenitally Deafblind Children and Cochlear Implants: Effects on Communication

    ERIC Educational Resources Information Center

    Dammeyer, Jesper

    2009-01-01

    There has been much research conducted demonstrating the positive benefits of cochlear implantation (CI) in children who are deaf. Research on CI in children who are both deaf and blind, however, is lacking. The purpose of this article is to present a study of five congenitally deafblind children who received cochlear implants between 2.2 and 4.2…

  7. Reduction in spread of excitation from current focusing at multiple cochlear locations in cochlear implant users.

    PubMed

    Padilla, Monica; Landsberger, David M

    2016-03-01

    Channel interaction from a broad spread of excitation is likely to be a limiting factor in performance by cochlear implant users. Although partial tripolar stimulation has been shown to reduce spread of excitation, the magnitude of the reduction is highly variable across subjects. Because the reduction in spread of excitation is typically only measured at one electrode for a given subject, the degree of variability across cochlear locations is unknown. The first goal of the present study was to determine if the reduction in spread of excitation observed from partial tripolar current focusing systematically varies across the cochlea. The second goal was to measure the variability in reduction of spread of excitation relative to monopolar stimulation across the cochlea. The third goal was to expand upon previous results that suggest that scaling of verbal descriptors can be used to predict the reduction in spread of excitation, by increasing the limited number of sites previously evaluated and verify the relationships remain with the larger dataset. The spread of excitation for monopolar and partial tripolar stimulation was measured at 5 cochlear locations using a psychophysical forward masking task. Results of the present study suggest that although partial tripolar stimulation typically reduces spread of excitation, the degree of reduction in spread of excitation was found to be highly variable and no effect of cochlear location was found. Additionally, subjective scaling of certain verbal descriptors (Clean/Dirty, Pure/Noisy) correlated with the reduction in spread of excitation suggesting sound quality scaling might be used as a quick clinical estimate of channels providing a reduction in spread of excitation. This quick scaling technique might help clinicians determine which patients would be most likely to benefit from a focused strategy. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Reduction in Spread of Excitation from Current Focusing at Multiple Cochlear Locations in Cochlear Implant Users

    PubMed Central

    Padilla, Monica; Landsberger, David M.

    2016-01-01

    Channel interaction from a broad spread of excitation is likely to be a limiting factor in performance by cochlear implant users. Although partial tripolar stimulation has been shown to reduce spread of excitation, the magnitude of the reduction is highly variable across subjects. Because the reduction in spread of excitation is typically only measured at one electrode for a given subject, the degree of variability across cochlear locations is unknown. The first goal of the present study was to determine if the reduction in spread of excitation observed from partial tripolar current focusing systematically varies across the cochlea. The second goal was to measure the variability in reduction of spread of excitation relative to monopolar stimulation across the cochlea. The third goal was to expand upon previous results that suggest that scaling of verbal descriptors can be used to predict the reduction in spread of excitation, by increasing the limited number of sites previously evaluated and verify the relationships remain with the larger dataset. The spread of excitation for monopolar and partial tripolar stimulation was measured at 5 cochlear locations using a psychophysical forward masking task. Results of the present study suggest that although partial tripolar stimulation typically reduces spread of excitation, the degree of reduction in spread of excitation was found to be highly variable and no effect of cochlear location was found. Additionally, subjective scaling of certain verbal descriptors (Clean/Dirty, Pure/Noisy) correlated with the reduction in spread of excitation suggesting sound quality scaling might be used as a quick clinical estimate of channels providing a reduction in spread of excitation. This quick scaling technique might help clinicians determine which patients would be most likely to benefit from a focused strategy. PMID:26778546

  9. Barriers to pediatric cochlear implantation: A parental survey.

    PubMed

    Yang, Charles Q; Reilly, Brian K; Preciado, Diego A

    2018-01-01

    This study aims to (1) determine barriers in the pediatric cochlear implantation process specific to publicly insured patients, wherein delayed implantation has been reported, and (2) compare the perceived barriers between publicly and privately insured patients. Tertiary care cochlear implantation center at academic pediatric hospital. Cross-sectional survey, retrospective chart review. The validated, 39 item Barriers to Care Questionnaire was administered to the parents of 80 recipients of cochlear implantation by two surgeons between 2013 and 2016. Survey results and diagnosis to implant interval were compared based on public or private insurance status. Two-tailed Mann-Whitney and Fisher's exact test was used for statistical analysis. Of 110 cochlear implants, 27 of 80 (34%) English-speaking parents completed the survey. 15 were privately insured and 12 were publicly insured. 23 of 27 respondents received cochlear implantation for pre-lingual sensorineural hearing loss. Publicly insured patients had significantly longer median time from diagnosis to implant than privately insured (19 vs. 8 mo, p = 0.01). The three worst scoring barrier categories for privately insured families in order were Pragmatics, Expectations, and Marginalization, whereas for publicly insured families it was Pragmatics, Skills, and Expectations. The worst scoring question for privately insured patients was "Having to take time off work". For the publicly insured, it was "Lack of communication." Privately insured patients reported more barriers on the Barriers to Care Questionnaire than publicly insured patients did. Although pragmatics was the worst-scoring barrier category for both groups, difficulties found on the survey ranked differently for each group. This information can help providers address disparities and access barriers for vulnerable patients. Published by Elsevier B.V.

  10. Self-reports about tinnitus and about cochlear implants.

    PubMed

    Noble, W

    2000-08-01

    Analyze literature on self-report outcomes in two areas of audiological rehabilitation: 1) tinnitus and 2) cochlear implant hearing aids. 1) Tinnitus: survey of features in the development of self-report approaches and of formal scales used in assessment of tinnitus disability and handicaps. 2) Cochlear implants: summary of the literature using self-report approaches to cochlear implant experience that indicates points of theoretical significance. 1) Major features of tinnitus are: a) disabilities such as interference with and distortion of normal auditory perception; b) handicaps such as emotional distress, interference with sleep, and with personal and social life. Nonauditory factors-chronic depression, high self-focused attention-mediate the degree of experienced tinnitus handicap. 2) People with prelingual loss of hearing report that a cochlear implant primarily enables improved detection and discrimination of environmental sound; those with postlingual loss find that an implant in addition provides improved speech recognition. 1) Coping with tinnitus is influenced by the personal resources that can be brought to bear on the experience, highlighting a general point that any rehabilitation outcome is not only a matter of acoustical solutions. By the same token, tinnitus can be easier to cope with if its "psychoacoustic presence" can be diminished by some form of masking. 2) Cochlear implants fitted in childhood that do not provide meaningful input signals in real-world settings may be rejected in adolescence. 3) "Hearing," as a capacity, does not have a fixed worth. Different circumstances mean it will be taken as desirable or as delivering torment (extreme tinnitus, e.g.). Its value will also vary depending on the extent of a person's access to spoken language (aiding in very early childhood, e.g.).

  11. Audiological outcomes of cochlear implantation in Waardenburg Syndrome

    PubMed Central

    Magalhães, Ana Tereza de Matos; Samuel, Paola Angélica; Goffi-Gomez, Maria Valeria Schimdt; Tsuji, Robinson Koji; Brito, Rubens; Bento, Ricardo Ferreira

    2013-01-01

    Summary Introduction: The most relevant clinical symptom in Waardenburg syndrome is profound bilateral sensorioneural hearing loss. Aim: To characterize and describe hearing outcomes after cochlear implantation in patients with Waardenburg syndrome to improve preoperative expectations. Method: This was an observational and retrospective study of a series of cases. Children who were diagnosed with Waardenburg syndrome and who received a multichannel cochlear implant between March 1999 and July 2012 were included in the study. Intraoperative neural response telemetry, hearing evaluation, speech perception, and speech production data before and after surgery were assessed. Results: During this period, 806 patients received a cochlear implant and 10 of these (1.2%) were diagnosed with Waardenburg syndrome. Eight of the children received a Nucleus 24® implant and 1 child and 1 adult received a DigiSonic SP implant. The mean age at implantation was 44 months among the children. The average duration of use of a cochlear implant at the time of the study was 43 months. Intraoperative neural responses were present in all cases. Patients who could use the speech processor effectively had a pure tone average of 31 dB in free-field conditions. In addition, the MUSS and MAIS questionnaires revealed improvements in speech perception and production. Four patients did not have a good outcome, which might have been associated with ineffective use of the speech processor. Conclusion: Despite the heterogeneity of the group, patients with Waardenburg syndrome who received cochlear implants were found to have hearing thresholds that allowed access to speech sounds. However, patients who received early intervention and rehabilitation showed better evolution of auditory perception. PMID:25992025

  12. Audiological outcomes of cochlear implantation in Waardenburg Syndrome.

    PubMed

    Magalhães, Ana Tereza de Matos; Samuel, Paola Angélica; Goffi-Gomez, Maria Valeria Schimdt; Tsuji, Robinson Koji; Brito, Rubens; Bento, Ricardo Ferreira

    2013-07-01

     The most relevant clinical symptom in Waardenburg syndrome is profound bilateral sensorioneural hearing loss.  To characterize and describe hearing outcomes after cochlear implantation in patients with Waardenburg syndrome to improve preoperative expectations.  This was an observational and retrospective study of a series of cases. Children who were diagnosed with Waardenburg syndrome and who received a multichannel cochlear implant between March 1999 and July 2012 were included in the study. Intraoperative neural response telemetry, hearing evaluation, speech perception, and speech production data before and after surgery were assessed.  During this period, 806 patients received a cochlear implant and 10 of these (1.2%) were diagnosed with Waardenburg syndrome. Eight of the children received a Nucleus 24(®) implant and 1 child and 1 adult received a DigiSonic SP implant. The mean age at implantation was 44 months among the children. The average duration of use of a cochlear implant at the time of the study was 43 months. Intraoperative neural responses were present in all cases. Patients who could use the speech processor effectively had a pure tone average of 31 dB in free-field conditions. In addition, the MUSS and MAIS questionnaires revealed improvements in speech perception and production. Four patients did not have a good outcome, which might have been associated with ineffective use of the speech processor.  Despite the heterogeneity of the group, patients with Waardenburg syndrome who received cochlear implants were found to have hearing thresholds that allowed access to speech sounds. However, patients who received early intervention and rehabilitation showed better evolution of auditory perception.

  13. Single and Multiple Microphone Noise Reduction Strategies in Cochlear Implants

    PubMed Central

    Azimi, Behnam; Hu, Yi; Friedland, David R.

    2012-01-01

    To restore hearing sensation, cochlear implants deliver electrical pulses to the auditory nerve by relying on sophisticated signal processing algorithms that convert acoustic inputs to electrical stimuli. Although individuals fitted with cochlear implants perform well in quiet, in the presence of background noise, the speech intelligibility of cochlear implant listeners is more susceptible to background noise than that of normal hearing listeners. Traditionally, to increase performance in noise, single-microphone noise reduction strategies have been used. More recently, a number of approaches have suggested that speech intelligibility in noise can be improved further by making use of two or more microphones, instead. Processing strategies based on multiple microphones can better exploit the spatial diversity of speech and noise because such strategies rely mostly on spatial information about the relative position of competing sound sources. In this article, we identify and elucidate the most significant theoretical aspects that underpin single- and multi-microphone noise reduction strategies for cochlear implants. More analytically, we focus on strategies of both types that have been shown to be promising for use in current-generation implant devices. We present data from past and more recent studies, and furthermore we outline the direction that future research in the area of noise reduction for cochlear implants could follow. PMID:22923425

  14. Noise-induced cochlear synaptopathy: Past findings and future studies.

    PubMed

    Kobel, Megan; Le Prell, Colleen G; Liu, Jennifer; Hawks, John W; Bao, Jianxin

    2017-06-01

    For decades, we have presumed the death of hair cells and spiral ganglion neurons are the main cause of hearing loss and difficulties understanding speech in noise, but new findings suggest synapse loss may be the key contributor. Specifically, recent preclinical studies suggest that the synapses between inner hair cells and spiral ganglion neurons with low spontaneous rates and high thresholds are the most vulnerable subcellular structures, with respect to insults during aging and noise exposure. This cochlear synaptopathy can be "hidden" because this synaptic loss can occur without permanent hearing threshold shifts. This new discovery of synaptic loss opens doors to new research directions. Here, we review a number of recent studies and make suggestions in two critical future research directions. First, based on solid evidence of cochlear synaptopathy in animal models, it is time to apply molecular approaches to identify the underlying molecular mechanisms; improved understanding is necessary for developing rational, effective therapies against this cochlear synaptopathy. Second, in human studies, the data supporting cochlear synaptopathy are indirect although rapid progress has been made. To fully identify changes in function that are directly related this hidden synaptic damage, we argue that a battery of tests including both electrophysiological and behavior tests should be combined for diagnosis of "hidden hearing loss" in clinical studies. This new approach may provide a direct link between cochlear synaptopathy and perceptual difficulties. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Cochlear Implantation, Enhancements, Transhumanism and Posthumanism: Some Human Questions.

    PubMed

    Lee, Joseph

    2016-02-01

    Biomedical engineering technologies such as brain-machine interfaces and neuroprosthetics are advancements which assist human beings in varied ways. There are exciting yet speculative visions of how the neurosciences and bioengineering may influence human nature. However, these could be preparing a possible pathway towards an enhanced and even posthuman future. This article seeks to investigate several ethical themes and wider questions of enhancement, transhumanism and posthumanism. Four themes of interest are: autonomy, identity, futures, and community. Three larger questions can be asked: will everyone be enhanced? Will we be "human" if we are not, one day, transhuman? Should we be enhanced or not? The article proceeds by concentrating on a widespread and sometimes controversial application: the cochlear implant, an auditory prosthesis implanted into Deaf patients. Cochlear implantation and its reception in both the deaf and hearing communities have a distinctive moral discourse, which can offer surprising insights. The paper begins with several points about the enhancement of human beings, transhumanism's reach beyond the human, and posthuman aspirations. Next it focuses on cochlear implants on two sides. Firstly, a shorter consideration of what technologies may do to humans in a transhumanist world. Secondly, a deeper analysis of cochlear implantation's unique socio-political movement, its ethical explanations and cultural experiences linked with pediatric cochlear implantation-and how those wary of being thrust towards posthumanism could marshal such ideas by analogy. As transhumanism approaches, the issues and questions merit continuing intense analysis.

  16. Classification and Current Management of Inner Ear Malformations.

    PubMed

    Sennaroğlu, Levent; Bajin, Münir Demir

    2017-09-29

    Morphologically congenital sensorineural hearing loss can be investigated under two categories. The majority of congenital hearing loss causes (80%) are membranous malformations. Here, the pathology involves inner ear hair cells. There is no gross bony abnormality and, therefore, in these cases high-resolution computerized tomography and magnetic resonance imaging of the temporal bone reveal normal findings. The remaining 20% have various malformations involving the bony labyrinth and, therefore, can be radiologically demonstrated by computerized tomography and magnetic resonance imaging. The latter group involves surgical challenges as well as problems in decision-making. Some cases may be managed by a hearing aid, others need cochlear implantation, and some cases are candidates for an auditory brainstem implantation (ABI). During cochlear implantation, there may be facial nerve abnormalities, cerebrospinal fluid leakage, electrode misplacement or difficulty in finding the cochlea itself. During surgery for inner ear malformations, the surgeon must be ready to modify the surgical approach or choose special electrodes for surgery. In the present review article, inner ear malformations are classified according to the differences observed in the cochlea. Hearing and language outcomes after various implantation methods are closely related to the status of the cochlear nerve, and a practical classification of the cochlear nerve deficiency is also provided.

  17. Pelvic widening to alleviate the mechanical component of constipation in a patient with severe caudal regression and extremely narrow pelvis.

    PubMed

    Sathya, Chethan; Ertresvaag, Kjetil; Wright, James; Azzie, Georges

    2013-05-01

    Constipation in children is a commonly encountered problem with a broad variety of causes. Constipation caused by a narrow pelvis has, to our knowledge, not been reported in the human literature. Retrospective review of patient chart, in depth follow-up appointment with the patient and review of literature. A 15 year old girl with sacral agenesis and significant co-morbidities was referred for consideration of cecostomy tube placement to manage her constipation. Digital rectal exam revealed a very narrow pelvic outlet and CT scan confirmed abnormal configuration of the bony pelvis. Discussions with orthopaedic colleagues concluded that bilateral pelvic osteotomies to widen her pelvis may relieve her constipation. The procedure was uneventful and radiologic follow-up confirmed widening of the pelvic outlet and increased pelvic volume. Her stooling pattern improved postoperatively and she was satisfied with the result on follow up at one year. Although previously described only in the veterinary literature, surgical widening of a narrow pelvis can be considered for the management of constipation in the rare patient with appropriate physical and radiologic findings. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. Negotiating Reassurance: Parents' Narratives on Follow-Up after Cochlear Implantation

    ERIC Educational Resources Information Center

    Bruin, Marieke; Ohna, Stein Erik

    2015-01-01

    This study presents an analysis of parental experiences on follow-up after cochlear implantation. Data were constructed in semi-structured, individual interviews with the parents of 14 children who use cochlear implants. Drawing on narrative analysis, the study explores parental responses to insecurity concerning children's learning and…

  19. Selective deletion of cochlear hair cells causes rapid age-dependent changes in spiral ganglion and cochlear nucleus neurons.

    PubMed

    Tong, Ling; Strong, Melissa K; Kaur, Tejbeer; Juiz, Jose M; Oesterle, Elizabeth C; Hume, Clifford; Warchol, Mark E; Palmiter, Richard D; Rubel, Edwin W

    2015-05-20

    During nervous system development, critical periods are usually defined as early periods during which manipulations dramatically change neuronal structure or function, whereas the same manipulations in mature animals have little or no effect on the same property. Neurons in the ventral cochlear nucleus (CN) are dependent on excitatory afferent input for survival during a critical period of development. Cochlear removal in young mammals and birds results in rapid death of target neurons in the CN. Cochlear removal in older animals results in little or no neuron death. However, the extent to which hair-cell-specific afferent activity prevents neuronal death in the neonatal brain is unknown. We further explore this phenomenon using a new mouse model that allows temporal control of cochlear hair cell deletion. Hair cells express the human diphtheria toxin (DT) receptor behind the Pou4f3 promoter. Injections of DT resulted in nearly complete loss of organ of Corti hair cells within 1 week of injection regardless of the age of injection. Injection of DT did not influence surrounding supporting cells directly in the sensory epithelium or spiral ganglion neurons (SGNs). Loss of hair cells in neonates resulted in rapid and profound neuronal loss in the ventral CN, but not when hair cells were eliminated at a more mature age. In addition, normal survival of SGNs was dependent on hair cell integrity early in development and less so in mature animals. This defines a previously undocumented critical period for SGN survival. Copyright © 2015 the authors 0270-6474/15/357878-14$15.00/0.

  20. Evaluation of pediatric cochlear implant care throughout Europe: Is European pediatric cochlear implant care performed according to guidelines?

    PubMed

    Bruijnzeel, Hanneke; Bezdjian, Aren; Lesinski-Schiedat, Anke; Illg, Angelika; Tzifa, Konstance; Monteiro, Luisa; Volpe, Antonio Della; Grolman, Wilko; Topsakal, Vedat

    2017-11-01

    International guidelines indicate that children with profound hearing loss should receive a cochlear implant (CI) soon after diagnosis in order to optimize speech and language rehabilitation. Although prompt rehabilitation is encouraged by current guidelines, delays in cochlear implantation are still present. This study investigated whether European countries establish timely pediatric CI care based on epidemiological, commercial, and clinical data. An estimation of the number of pediatric CI candidates in European countries was performed and compared to epidemiological (Euro-CIU), commercial (Cochlear ® ), and clinical (institutional) age-at-implantation data. The ages at implantation of pediatric patients in eight countries (the Netherlands, Belgium, Germany, the United Kingdom, France, Turkey, Portugal, and Italy) between 2005 and 2015 were evaluated. From 2010 onwards, over 30% of the pediatric CI candidates were implanted before 24 months of age. Northern European institutions implanted children on average around 12 months of age, whereas southern European institutions implanted children after 18 months of age. The Netherlands and Germany implanted earliest (between 6 and 11 months). Implemented newborn hearing screening programs and reimbursement rates of CIs vary greatly within Europe due to local, social, financial, and political differences. However, internationally accepted recommendations are applicable to this heterogeneous European CI practice. Although consensus on early pediatric cochlear implantation exists, this study identified marked delays in European care. Regardless of the great heterogeneity in European practice, reasons for latency should be identified on a national level and possibilities to prevent avoidable future implantation delays should be explored to provide national recommendations.

  1. Effects of cochlear ablation on choline acetyltransferase activity in the rat cochlear nucleus and superior olive.

    PubMed

    Jin, Yong-Ming; Godfrey, Donald A; Sun, Yizhe

    2005-07-01

    Using microdissection and quantitative microassay, choline acetyltransferase (ChAT) activity was mapped in the cochlear nucleus (CN) and in the source nuclei of the olivocochlear bundle, the lateral superior olive and ventral nucleus of the trapezoid body. In control rats, gradients of ChAT activity were found within the major subdivisions of the CN and in the lateral superior olive. These gradients correlated with the known tonotopic organizations, with higher activities corresponding to locations representing higher sound frequencies. No gradient was found in the ventral nucleus of the trapezoid body. In rats surviving 7 days or 1 or 2 months after cochlear ablation, ChAT activity was increased 1 month after ablation in the anteroventral CN by 30-50% in most parts of the lesion-side and by 40% in the contralateral ventromedial part. ChAT activity in the lesion-side posteroventral CN was increased by approximately 40-50% at all survival times. Little change was found in the dorsal CN. Decreases of ChAT activity were also found ipsilaterally in the lateral superior olive and bilaterally in the ventral nucleus of the trapezoid body. Our results suggest that cholinergic neurons are involved in plasticity within the CN and superior olive following cochlear lesions. Copyright 2005 Wiley-Liss, Inc.

  2. [The contribution of different cochlear insertion region to Mandarin speech perception in users of cochlear implant].

    PubMed

    Qi, Beier; Liu, Bo; Liu, Sha; Liu, Haihong; Dong, Ruijuan; Zhang, Ning; Gong, Shusheng

    2011-05-01

    To study the effect of cochlear electrode coverage and different insertion region on speech recognition, especially tone perception of cochlear implant users whose native language is Mandarin Chinese. Setting seven test conditions by fitting software. All conditions were created by switching on/off respective channels in order to simulate different insertion position. Then Mandarin CI users received 4 Speech tests, including Vowel Identification test, Consonant Identification test, Tone Identification test-male speaker, Mandarin HINT test (SRS) in quiet and noise. To all test conditions: the average score of vowel identification was significantly different, from 56% to 91% (Rank sum test, P < 0.05). The average score of consonant identification was significantly different, from 72% to 85% (ANOVNA, P < 0.05). The average score of Tone identification was not significantly different (ANOVNA, P > 0.05). However the more channels activated, the higher scores obtained, from 68% to 81%. This study shows that there is a correlation between insertion depth and speech recognition. Because all parts of the basement membrane can help CI users to improve their speech recognition ability, it is very important to enhance verbal communication ability and social interaction ability of CI users by increasing insertion depth and actively stimulating the top region of cochlear.

  3. Labyrinthectomy with cochlear implantation.

    PubMed

    Zwolan, T A; Shepard, N T; Niparko, J K

    1993-05-01

    Numerous reports indicate that the cochlea remains responsive to electrical stimulation following labyrinthectomy. We report a case of a 47-year-old woman with a severe to profound sensorineural hearing loss from birth, who developed episodic vertigo with symptoms suggestive of delayed onset endolymphatic hydrops. Following 8 months of failed medical and vestibular rehabilitation management, a right-sided labyrinthectomy combined with cochlear implantation was performed without complication. Postoperatively the patient was free of vertigo. Attempts to activate the patient's device between 4 to 12 weeks after surgery were unsuccessful as stimulation of the electrodes resulted in discomfort. However, all 20 electrodes elicited comfortable hearing sensations 16 weeks postsurgery. One year after the successful activation, the patient demonstrated improved sound awareness and speech recognition with the implant when compared with preoperative performance with a hearing aid. This case study suggests that electrical detection thresholds with prosthetic stimulation may be unstable in the recently labyrinthectomized ear but supports and extends prior observations of preserved cochlear responsiveness after labyrinthectomy.

  4. Challenges in Optimizing Oral Communication in Children with Cochlear Implants.

    ERIC Educational Resources Information Center

    Ertmer, David J.

    2002-01-01

    This article introduces a forum that provides information for assisting speech-language pathologists and audiologists in fulfilling their professional responsibilities in a variety of settings to children with hearing impairments who have cochlear implants. A preview of the following articles on services for children with cochlear implants is…

  5. Betahistine metabolites, aminoethylpyridine, and hydroxyethylpyridine increase cochlear blood flow in guinea pigs in vivo.

    PubMed

    Bertlich, Mattis; Ihler, Fritz; Sharaf, Kariem; Weiss, Bernhard G; Strupp, Michael; Canis, Martin

    2014-10-01

    Betahistine is a histamine-like drug that is used in the treatment of Ménière's disease. It is commonly believed that betahistine increases cochlear blood flow and thus decreases the endolymphatic hydrops that is the cause of Ménière's. Despite common clinical use, there is little understanding of the kinetics or effects of its metabolites. This study investigated the effect of the betahistine metabolites aminoethylpyridine, hydroxyethylpyridine, and pyridylacetic acid on cochlear microcirculation. Guinea pigs were randomly assigned to one of the groups: placebo, betahistine, or equimolar amounts of aminoethylpyridine, hydroxyethylpyridine, or pyridylacetic acid. Cochlear blood flow and mean arterial pressure were recorded for three minutes before and 15 minutes after treatment. Thirty Dunkin-Hartley guinea pigs assigned to one of five groups with six guinea pigs per group. Betahistine, aminoethylpyridine, and hydroxyethylpyridine caused a significant increase in cochlear blood flow in comparison to placebo. The effect seen under aminoethylpyridin was greatest. The group treated with pyridylacetic acid showed no significant effect on cochlear blood flow. Aminoethylpyridine and hydroxyethylpyridine are, like betahistine, able to increase cochlear blood flow significantly. The effect of aminoethylpyridine was greatest. Pyridylacetic acid had no effect on cochlear microcirculation.

  6. Use of Neural Response Telemetry for Pediatric Cochlear Implants: Current Practice.

    PubMed

    Almosnino, Galit; Anne, Samantha; Schwartz, Seth R

    2018-06-01

    Evaluate usage trends of neural response telemetry (NRT) in cochlear implant centers across the nation and assess reported benefits of intraoperative NRT for pediatric cochlear implant recipients. Survey. All US cochlear implant centers (n = 110). A 15-question multiple-choice survey was distributed electronically to all centers. The survey captured demographic information of all centers, practice patterns surrounding the use of NRT, and the extent to which intraoperative NRT is of benefit. Thirty-two invited participants (29%) completed the survey. A majority of participants reported practicing in an academic center (66%), followed by a hospital setting (19%) and private practice (16%). Seventy-two percent of survey participants reported using NRT for pediatric cochlear implant recipients. Sixty-three percent felt it improved the ability to program at initial activation, and 50% of participants felt that NRT improves satisfaction at initial activation. This study suggests that a majority of surgeons use intraoperative NRT for pediatric cochlear implantation as an additional measure to ensure appropriate electrode placement and improve device activation. Larger studies are needed to better establish the relationship between intraoperative NRT and postoperative outcomes and justify the additional costs associated with intraoperative NRT.

  7. Effects of a Word-Learning Training on Children With Cochlear Implants

    PubMed Central

    Lund, Emily

    2014-01-01

    Preschool children with hearing loss who use cochlear implants demonstrate vocabulary delays when compared to their peers without hearing loss. These delays may be a result of deficient word-learning abilities; children with cochlear implants perform more poorly on rapid word-learning tasks than children with normal hearing. This study explored the malleability of rapid word learning of preschoolers with cochlear implants by evaluating the effects of a word-learning training on rapid word learning. A single-subject, multiple probe design across participants measured the impact of the training on children’s rapid word-learning performance. Participants included 5 preschool children with cochlear implants who had an expressive lexicon of less than 150 words. An investigator guided children to identify, repeat, and learn about unknown sets of words in 2-weekly sessions across 10 weeks. The probe measure, a rapid word-learning task with a different set of words than those taught during training, was collected in the baseline, training, and maintenance conditions. All participants improved their receptive rapid word-learning performance in the training condition. The functional relation indicates that the receptive rapid word-learning performance of children with cochlear implants is malleable. PMID:23981321

  8. Spectral-Temporal Modulated Ripple Discrimination by Children With Cochlear Implants.

    PubMed

    Landsberger, David M; Padilla, Monica; Martinez, Amy S; Eisenberg, Laurie S

    A postlingually implanted adult typically develops hearing with an intact auditory system, followed by periods of deafness (or near deafness) and adaptation to the implant. For an early implanted child whose brain is highly plastic, the auditory system matures with consistent input from a cochlear implant. It is likely that the auditory system of early implanted cochlear implant users is fundamentally different than postlingually implanted adults. The purpose of this study is to compare the basic psychophysical capabilities and limitations of these two populations on a spectral resolution task to determine potential effects of early deprivation and plasticity. Performance on a spectral resolution task (Spectral-temporally Modulated Ripple Test [SMRT]) was measured for 20 bilaterally implanted, prelingually deafened children (between 5 and 13 years of age) and 20 hearing children within the same age range. Additionally, 15 bilaterally implanted, postlingually deafened adults, and 10 hearing adults were tested on the same task. Cochlear implant users (adults and children) were tested bilaterally, and with each ear alone. Hearing listeners (adults and children) were tested with the unprocessed SMRT and with a vocoded version that simulates an 8-channel cochlear implant. For children with normal hearing, a positive correlation was found between age and SMRT score for both the unprocessed and vocoded versions. Older hearing children performed similarly to hearing adults in both the unprocessed and vocoded test conditions. However, for children with cochlear implants, no significant relationship was found between SMRT score and chronological age, age at implantation, or years of implant experience. Performance by children with cochlear implants was poorer than performance by cochlear implanted adults. It was also found that children implanted sequentially tended to have better scores with the first implant compared with the second implant. This difference was not

  9. Surgical evaluation of candidates for cochlear implants

    NASA Technical Reports Server (NTRS)

    Black, F. O.; Lilly, D. J.; Fowler, L. P.; Stypulkowski, P. H.

    1987-01-01

    The customary presentation of surgical procedures to patients in the United States consists of discussions on alternative treatment methods, risks of the procedure(s) under consideration, and potential benefits for the patient. Because the contents of the normal speech signal have not been defined in a way that permits a surgeon systematically to provide alternative auditory signals to a deaf patient, the burden is placed on the surgeon to make an arbitrary selection of candidates and available devices for cochlear prosthetic implantation. In an attempt to obtain some information regarding the ability of a deaf patient to use electrical signals to detect and understand speech, the Good Samaritan Hospital and Neurological Sciences Institute cochlear implant team has routinely performed tympanotomies using local anesthesia and has positioned temporary electrodes onto the round windows of implant candidates. The purpose of this paper is to review our experience with this procedure and to provide some observations that may be useful in a comprehensive preoperative evaluation for totally deaf patients who are being considered for cochlear implantation.

  10. Implications of Minimizing Trauma During Conventional Cochlear Implantation

    PubMed Central

    Carlson, Matthew L.; Driscoll, Colin L. W.; Gifford, René H.; Service, Geoffrey J.; Tombers, Nicole M.; Hughes-Borst, Becky J.; Neff, Brian A.; Beatty, Charles W.

    2014-01-01

    Objective To describe the relationship between implantation-associated trauma and postoperative speech perception scores among adult and pediatric patients undergoing cochlear implantation using conventional length electrodes and minimally traumatic surgical techniques. Study Design Retrospective chart review (2002–2010). Setting Tertiary academic referral center. Patients All subjects with significant preoperative low-frequency hearing (≤70 dB HL at 250 Hz) who underwent cochlear implantation with a newer generation implant electrode (Nucleus Contour Advance, Advanced Bionics HR90K [1J and Helix], and Med El Sonata standard H array) were reviewed. Intervention(s) Preimplant and postimplant audiometric thresholds and speech recognition scores were recorded using the electronic medical record. Main Outcome Measure(s) Postimplantation pure tone threshold shifts were used as a surrogate measure for extent of intracochlear injury and correlated with postoperative speech perception scores. Results Between 2002 and 2010, 703 cochlear implant (CI) operations were performed. Data from 126 implants were included in the analysis. The mean preoperative low-frequency pure-tone average was 55.4 dB HL. Hearing preservation was observed in 55% of patients. Patients with hearing preservation were found to have significantly higher postoperative speech perception performance in the cochlear implantation-only condition than those who lost all residual hearing. Conclusion Conservation of acoustic hearing after conventional length cochlear implantation is unpredictable but remains a realistic goal. The combination of improved technology and refined surgical technique may allow for conservation of some residual hearing in more than 50% of patients. Germane to the conventional length CI recipient with substantial hearing loss, minimizing trauma allows for improved speech perception in the electric condition. These findings support the use of minimally traumatic techniques in all CI

  11. Using Flanagan's phase vocoder to improve cochlear implant performance

    NASA Astrophysics Data System (ADS)

    Zeng, Fan-Gang

    2004-10-01

    The cochlear implant has restored partial hearing to more than 100000 deaf people worldwide, allowing the average user to talk on the telephone in quiet environment. However, significant difficulty still remains for speech recognition in noise, music perception, and tonal language understanding. This difficulty may be related to speech processing strategies in current cochlear implants that emphasized the extraction and encoding of the temporal envelope while ignoring the temporal fine structure in speech sounds. A novel strategy was developed based on Flanagan's phase vocoder [Flanagan and Golden, Bell Syst. Tech. 45, 1493-1509 (1966)], in which frequency modulation was extracted from the temporal fine structure and then added to amplitude modulation in the current cochlear implants. Acoustic simulation results showed that amplitude and frequency modulation contributed complementarily to speech perception with amplitude modulation contributing mainly to intelligibility whereas frequency modulation contributed to speaker identification and auditory grouping. The results also showed that the novel strategy significantly improved cochlear implant performance under realistic listening situations. Overall, the present result demonstrated that Flanagan's classic work on phase vocoder still shed insight on current problems of both theoretical and practical importance. [Work supported by NIH.

  12. Realization of Complex Onsets by Pediatric Users of Cochlear Implants

    ERIC Educational Resources Information Center

    Chin, Steven B.

    2006-01-01

    This study examined variations in English complex onset realizations by children who use cochlear implants. Data consisted of 227 productions of two-segment onset clusters from 12 children. In general, onset cluster realizations of children with cochlear implants did not differ markedly from those reported for children with normal hearing: null…

  13. Evaluating the Feasibility of Using Remote Technology for Cochlear Implants

    ERIC Educational Resources Information Center

    Goehring, Jenny L.; Hughes, Michelle L.; Baudhuin, Jacquelyn L.

    2012-01-01

    The use of remote technology to provide cochlear implant services has gained popularity in recent years. This article contains a review of research evaluating the feasibility of remote service delivery for recipients of cochlear implants. To date, published studies have determined that speech-processor programming levels and other objective tests…

  14. Bony Pelvis Dimensions in Women With and Without Stress Urinary Incontinence

    PubMed Central

    Berger, Mitchell B.; Doumouchtsis, Stergios K.; DeLancey, John O.

    2012-01-01

    AIMS To test the null hypothesis that bony pelvis dimensions are similar in women with and without stress urinary incontinence, both in the postpartum and midlife periods. METHODS Secondary analyses were performed of two case-control studies comparing women with stress urinary incontinence to asymptomatic controls. One study examined primiparas in the first 9–12 months postpartum; the other study involved middle-aged women. Stress urinary incontinence was confirmed by full-bladder stress test. All subjects underwent pelvic magnetic resonance imaging. The interspinous and intertuberous diameters, subpubic angle and sacrococcygeal joint-to-the inferior pubic point distance were measured from the images independently by two authors. RESULTS In the young cohorts, we compared primiparas with de novo postpartum stress urinary incontinence to both continent primiparas and nulliparas. Postpartum stress urinary incontinence is associated with a wider subpubic angle. There is also a trend towards wider interspinous and intertuberous diameters in the stress-incontinent primiparas as compared to the continent cohorts, although this did not reach statistical significance with our sample sizes. By contrast, no significant differences in bony pelvis dimensions were identified when comparing middle-aged women with stress urinary incontinence and their continent controls. CONCLUSIONS Bony pelvis dimensions are different in women with stress urinary incontinence than in matched continent controls. However, these differences are only identified in young primiparas in the postpartum period, not in middle-aged women. PMID:22674676

  15. Response of cochlear blood flow to prostaglandin E1 applied topically to the round window.

    PubMed

    Tominaga, Mitsuo; Yamamoto, Hiroshi; Sone, Michihiko; Teranishi, Masa-aki; Nakashima, Tsutomu

    2006-03-01

    The increase in cochlear blood flow (CBF) after administration of prostaglandin E1 (PGE1) to the round window depends on increased blood flow through the anterior inferior cerebellar artery (AICA). To evaluate the response of CBF to PGE1 applied topically to the round window, and to investigate the origin of blood flow changes after this topical application. The response of CBF to topically applied PGE1 was measured by placing the tip of a laser Doppler probe on the bony wall of the basal turn of the cochlea after the middle ear mucosa over the cochlea had been removed in guinea pigs and rats. In rats, the CBF response to PGE1 administration was investigated after occlusion of the AICA or stapedial artery. CBF increased following PGE1 administration in both guinea pigs and rats. In rats, CBF increased from 100% to 132%+/-10% (mean+/-SD) after the topical application of 0.5 microl of a 0.014% PGE1 solution. CBF decreased after occlusion of the AICA or stapedial artery but did not increase after PGE1 administration during occlusion of the AICA. The CBF response to PGE1 administration was similar before and after occlusion of the stapedial artery.

  16. Comparison of carina-based versus bony anatomy-based registration for setup verification in esophageal cancer radiotherapy.

    PubMed

    Machiels, Mélanie; Jin, Peng; van Gurp, Christianne H; van Hooft, Jeanin E; Alderliesten, Tanja; Hulshof, Maarten C C M

    2018-03-21

    To investigate the feasibility and geometric accuracy of carina-based registration for CBCT-guided setup verification in esophageal cancer IGRT, compared with current practice bony anatomy-based registration. Included were 24 esophageal cancer patients with 65 implanted fiducial markers, visible on planning CTs and follow-up CBCTs. All available CBCT scans (n = 236) were rigidly registered to the planning CT with respect to the bony anatomy and the carina. Target coverage was visually inspected and marker position variation was quantified relative to both registration approaches; the variation of systematic (Σ) and random errors (σ) was estimated. Automatic carina-based registration was feasible in 94.9% of the CBCT scans, with an adequate target coverage in 91.1% compared to 100% after bony anatomy-based registration. Overall, Σ (σ) in the LR/CC/AP direction was 2.9(2.4)/4.1(2.4)/2.2(1.8) mm using the bony anatomy registration compared to 3.3(3.0)/3.6(2.6)/3.9(3.1) mm for the carina. Mid-thoracic placed markers showed a non-significant but smaller Σ in CC and AP direction when using the carina-based registration. Compared with a bony anatomy-based registration, carina-based registration for esophageal cancer IGRT results in inadequate target coverage in 8.9% of cases. Furthermore, large Σ and σ, requiring larger anisotropic margins, were seen after carina-based registration. Only for tumors entirely confined to the mid-thoracic region the carina-based registration might be slightly favorable.

  17. Cochlear perfusion with a viscous fluid.

    PubMed

    Wang, Yi; Olson, Elizabeth S

    2016-07-01

    The flow of viscous fluid in the cochlea induces shear forces, which could provide benefit in clinical practice, for example to guide cochlear implant insertion or produce static pressure to the cochlear partition or wall. From a research standpoint, studying the effects of a viscous fluid in the cochlea provides data for better understanding cochlear fluid mechanics. However, cochlear perfusion with a viscous fluid may damage the cochlea. In this work we studied the physiological and anatomical effects of perfusing the cochlea with a viscous fluid. Gerbil cochleae were perfused at a rate of 2.4 μL/min with artificial perilymph (AP) and sodium hyaluronate (Healon, HA) in four different concentrations (0.0625%, 0.125%, 0.25%, 0.5%). The different HA concentrations were applied either sequentially in the same cochlea or individually in different cochleae. The perfusion fluid entered from the round window and was withdrawn from basal scala vestibuli, in order to perfuse the entire perilymphatic space. Compound action potentials (CAP) were measured after each perfusion. After perfusion with increasing concentrations of HA in the order of increasing viscosity, the CAP thresholds generally increased. The threshold elevation after AP and 0.0625% HA perfusion was small or almost zero, and the 0.125% HA was a borderline case, while the higher concentrations significantly elevated CAP thresholds. Histology of the cochleae perfused with the 0.0625% HA showed an intact Reissner's membrane (RM), while in cochleae perfused with 0.125% and 0.25% HA RM was torn. Thus, the CAP threshold elevation was likely due to the broken RM, likely caused by the shear stress produced by the flow of the viscous fluid. Our results and analysis indicate that the cochlea can sustain, without a significant CAP threshold shift, up to a 1.5 Pa shear stress. Beside these finding, in the 0.125% and 0.25% HA perfusion cases, a temporary CAP threshold shift was observed, perhaps due to the presence and

  18. Cochlear perfusion with a viscous fluid

    PubMed Central

    Wang, Yi; Olson, Elizabeth S.

    2016-01-01

    The flow of viscous fluid in the cochlea induces shear forces, which could provide benefit in clinical practice, for example to guide cochlear implant insertion or produce static pressure to the cochlear partition or wall. From a research standpoint, studying the effects of a viscous fluid in the cochlea provides data for better understanding cochlear fluid mechanics. However, cochlear perfusion with a viscous fluid may damage the cochlea. In this work we studied the physiological and anatomical effects of perfusing the cochlea with a viscous fluid. Gerbil cochleae were perfused at a rate of 2.4 μL/min with artificial perilymph (AP) and sodium hyaluronate (Healon, HA) in four different concentrations (0.0625%, 0.125%, 0.25%, 0.5%). The different HA concentrations were applied either sequentially in the same cochlea or individually in different cochleae. The perfusion fluid entered from the round window and was withdrawnfrom basal scala vestibuli, in order to perfuse the entire perilymphatic space. Compound action potentials (CAP) were measured after each perfusion. After perfusion with increasing concentrations of HA in the order of increasing viscosity, the CAP thresholds generally increased. The threshold elevation after AP and 0.0625% HA perfusion was small or almost zero, and the 0.125% HA was a borderline case, while the higher concentrations significantly elevated CAP thresholds. Histology of the cochleae perfused with the 0.0625% HA showed an intact Reissner’s membrane, while in cochleae perfused with 0.125% and 0.25% HA Reissner’s membrane (RM) was torn. Thus, the CAP threshold elevation was likely due to the broken of RM, which likely caused by the shear stress produced by the flow of the viscous fluid. Our results and analysis indicate that the cochlea can sustain, without a significant CAP threshold shift, up to a 1.5 Pa shear stress. Beside these finding, in the 0.125% and 0.25% HA perfusion cases, a temporary CAP threshold shift was observed

  19. Cochlear implants and ex vivo BDNF gene therapy protect spiral ganglion neurons.

    PubMed

    Rejali, Darius; Lee, Valerie A; Abrashkin, Karen A; Humayun, Nousheen; Swiderski, Donald L; Raphael, Yehoash

    2007-06-01

    Spiral ganglion neurons often degenerate in the deaf ear, compromising the function of cochlear implants. Cochlear implant function can be improved by good preservation of the spiral ganglion neurons, which are the target of electrical stimulation by the implant. Brain derived neurotrophic factor (BDNF) has previously been shown to enhance spiral ganglion survival in experimentally deafened ears. Providing enhanced levels of BDNF in human ears may be accomplished by one of several different methods. The goal of these experiments was to test a modified design of the cochlear implant electrode that includes a coating of fibroblast cells transduced by a viral vector with a BDNF gene insert. To accomplish this type of ex vivo gene transfer, we transduced guinea pig fibroblasts with an adenovirus with a BDNF gene cassette insert, and determined that these cells secreted BDNF. We then attached BDNF-secreting cells to the cochlear implant electrode via an agarose gel, and implanted the electrode in the scala tympani. We determined that the BDNF expressing electrodes were able to preserve significantly more spiral ganglion neurons in the basal turns of the cochlea after 48 days of implantation when compared to control electrodes. This protective effect decreased in the higher cochlear turns. The data demonstrate the feasibility of combining cochlear implant therapy with ex vivo gene transfer for enhancing spiral ganglion neuron survival.

  20. Is there a best side for cochlear implants in post-lingual patients?

    PubMed

    Amaral, Maria Stella Arantes do; Damico, Thiago A; Gonçales, Alina S; Reis, Ana C M B; Isaac, Myriam de Lima; Massuda, Eduardo T; Hyppolito, Miguel Angelo

    2017-07-29

    Cochlear Implant is a sensory prosthesis capable of restoring hearing in patients with severe or profound bilateral sensorineural hearing loss. To evaluate if there is a better side to be implanted in post-lingual patients. Retrospective longitudinal study. Participants were 40 subjects, of both sex, mean age of 47 years, with post-lingual hearing loss, users of unilateral cochlear implant for more than 12 months and less than 24 months, with asymmetric auditor reserve between the ears (difference of 10dBNA, In at least one of the frequencies with a response, between the ears), divided into two groups. Group A was composed of individuals with cochlear implant in the ear with better auditory reserve and Group B with auditory reserve lower in relation to the contralateral side. There was no statistical difference for the tonal auditory threshold before and after cochlear implant. A better speech perception in pre-cochlear implant tests was present in B (20%), but the final results are similar in both groups. The cochlear implant in the ear with the worst auditory residue favors a bimodal hearing, which would allow the binaural summation, without compromising the improvement of the audiometric threshold and the speech perception. Copyright © 2017 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  1. Spatiotemporal expression of Ezh2 in the developing mouse cochlear sensory epithelium.

    PubMed

    Chen, Yan; Li, Wenyan; Li, Wen; Chai, Renjie; Li, Huawei

    2016-09-01

    The enhancer of zeste 2 polycomb repressive complex 2 subunit (Ezh2) is a histone-lysine Nmethyltransferase enzyme that participates in DNA methylation. Ezh2 has also been reported to play crucial roles in stem cell proliferation and differentiation. However, the detailed expression profile of Ezh2 during mouse cochlear development has not been investigated. Here, we examined the spatiotemporal expression of Ezh2 in the cochlea during embryonic and postnatal development. Ezh2 expression began to be observed in the whole otocyst nuclei at embryonic day 9.5 (E9.5). At E12.5, Ezh2 was expressed in the nuclei of the cochlear prosensory epithelium. At E13.5 and E15.5, Ezh2 was expressed from the apical to the basal turns in the nuclei of the differentiating cochlear epithelium. At postnatal day (P) 0 and 7, the Ezh2 expression was located in the nuclei of the cochlear epithelium in all three turns and could be clearly seen in outer and inner hair cells, supporting cells, the stria vascularis, and spiral ganglion cells. Ezh2 continued to be expressed in the cochlear epithelium of adult mice. Our results provide the basic Ezh2 expression pattern and might be useful for further investigating the detailed role of Ezh2 during cochlear development.

  2. Benefit and predictive factors for speech perception outcomes in pediatric bilateral cochlear implant recipients.

    PubMed

    Chang, Young-Soo; Hong, Sung Hwa; Kim, Eun Yeon; Choi, Ji Eun; Chung, Won-Ho; Cho, Yang-Sun; Moon, Il Joon

    2018-05-18

    Despite recent advancement in the prediction of cochlear implant outcome, the benefit of bilateral procedures compared to bimodal stimulation and how we predict speech perception outcomes of sequential bilateral cochlear implant based on bimodal auditory performance in children remain unclear. This investigation was performed: (1) to determine the benefit of sequential bilateral cochlear implant and (2) to identify the associated factors for the outcome of sequential bilateral cochlear implant. Observational and retrospective study. We retrospectively analyzed 29 patients with sequential cochlear implant following bimodal-fitting condition. Audiological evaluations were performed; the categories of auditory performance scores, speech perception with monosyllable and disyllables words, and the Korean version of Ling. Audiological evaluations were performed before sequential cochlear implant with the bimodal fitting condition (CI1+HA) and one year after the sequential cochlear implant with bilateral cochlear implant condition (CI1+CI2). The good Performance Group (GP) was defined as follows; 90% or higher in monosyllable and bisyllable tests with auditory-only condition or 20% or higher improvement of the scores with CI1+CI2. Age at first implantation, inter-implant interval, categories of auditory performance score, and various comorbidities were analyzed by logistic regression analysis. Compared to the CI1+HA, CI1+CI2 provided significant benefit in categories of auditory performance, speech perception, and Korean version of Ling results. Preoperative categories of auditory performance scores were the only associated factor for being GP (odds ratio=4.38, 95% confidence interval - 95%=1.07-17.93, p=0.04). The children with limited language development in bimodal condition should be considered as the sequential bilateral cochlear implant and preoperative categories of auditory performance score could be used as the predictor in speech perception after sequential

  3. Music training improves pitch perception in prelingually deafened children with cochlear implants.

    PubMed

    Chen, Joshua Kuang-Chao; Chuang, Ann Yi Chiun; McMahon, Catherine; Hsieh, Jen-Chuen; Tung, Tao-Hsin; Li, Lieber Po-Hung

    2010-04-01

    The comparatively poor music appreciation in patients with cochlear implants might be ascribed to an inadequate exposure to music; however, the effect of training on music perception in prelingually deafened children with cochlear implants remains unknown. This study aimed to investigate whether previous musical education improves pitch perception ability in these children. Twenty-seven children with congenital/prelingual deafness of profound degree were studied. Test stimuli consisted of 2 sequential piano tones, ranging from C (256 Hz) to B (495 Hz). Children were asked to identify the pitch relationship between the 2 tones (same, higher, or lower). Effects of musical training duration, pitch-interval size, current age, age of implantation, gender, and type of cochlear implant on accuracy of pitch perception were evaluated. The duration of musical training positively correlated with the correct rate of pitch perception. Pitch perception performance was better in children who had a cochlear implant and were older than 6 years than in those who were aged < or =6 years (ie, preschool). Effect of pitch-interval size was insignificant on pitch perception, and there was no correlation between pitch perception and the age of implantation, gender, or type of cochlear implant. Musical training seems to improve pitch perception ability in prelingually deafened children with a cochlear implant. Auditory plasticity might play an important role in such enhancement. This suggests that incorporation of a structured training program on music perception early in life and as part of the postoperative rehabilitation program for prelingually deafened children with cochlear implants would be beneficial. A longitudinal study is needed to show whether improvement of music performance in these children is measurable by use of auditory evoked potentials.

  4. Auditory Speech Perception Development in Relation to Patient's Age with Cochlear Implant

    PubMed Central

    Ciscare, Grace Kelly Seixas; Mantello, Erika Barioni; Fortunato-Queiroz, Carla Aparecida Urzedo; Hyppolito, Miguel Angelo; Reis, Ana Cláudia Mirândola Barbosa dos

    2017-01-01

    Introduction  A cochlear implant in adolescent patients with pre-lingual deafness is still a debatable issue. Objective  The objective of this study is to analyze and compare the development of auditory speech perception in children with pre-lingual auditory impairment submitted to cochlear implant, in different age groups in the first year after implantation. Method  This is a retrospective study, documentary research, in which we analyzed 78 reports of children with severe bilateral sensorineural hearing loss, unilateral cochlear implant users of both sexes. They were divided into three groups: G1, 22 infants aged less than 42 months; G2, 28 infants aged between 43 to 83 months; and G3, 28 older than 84 months. We collected medical record data to characterize the patients, auditory thresholds with cochlear implants, assessment of speech perception, and auditory skills. Results  There was no statistical difference in the association of the results among groups G1, G2, and G3 with sex, caregiver education level, city of residence, and speech perception level. There was a moderate correlation between age and hearing aid use time, age and cochlear implants use time. There was a strong correlation between age and the age cochlear implants was performed, hearing aid use time and age CI was performed. Conclusion  There was no statistical difference in the speech perception in relation to the patient's age when cochlear implant was performed. There were statistically significant differences for the variables of auditory deprivation time between G3 - G1 and G2 - G1 and hearing aid use time between G3 - G2 and G3 - G1. PMID:28680487

  5. [Reliable fixation of cochlear implant electrode mountings in children and adults--initial experiences with a new titanium clip].

    PubMed

    Müller, J; Schön, F; Helms, J

    1998-04-01

    There is a reported 1% incidence of delayed migration of extrusions of the electrode arrays out of the cochlea. A titanium clip to fix the electrode array of the MED EL Combi 40 Cochlear Implant System is described. The clip is designed and shaped in a double U configuration. The clip material allows easy adaption to the individual anatomical situation. The clip is fixed to a bony bridge at the incus bar and fixes the electrode in a plane parallel to the chorda facial angle. It is closed around the electrode similarly to a stapes piston around the incus. Additional tests which examined the possible risk of damaging the electrode carrier and clinical findings are described. The clip was used in 23 cases with a follow-up period up to 1 year. No signs for dislocation of the electrode were found. In one revision case the clip was covered with a thin mucosal layer. The electrode array showed no signs of damage. Intraoperative findings confirmed the experimental tests on the electrode fixation. The titanium clip facilitates safe and quick fixation of the electrode array and prevents dislocation. its flexibility and shape minimizes the risk of damage.

  6. Primary malignant tumours of the bony pelvis: US-guided high intensity focused ultrasound ablation.

    PubMed

    Wang, Yang; Wang, Wei; Tang, Jie

    2013-11-01

    The aim of this review is to evaluate the value of ultrasound (US)-guided high intensity focused ultrasound (HIFU) ablation in the treatment of primary malignant tumours of the bony pelvis. Eleven patients with primary malignant tumours of the bony pelvis received US-guided HIFU ablation. The maximum tumour size ranged from 5.6 to 25.0 cm (median 10.5 cm). Treatment was curative in four patients and palliative in seven patients. During follow-up, the effectiveness of HIFU ablation was assessed by contrast-enhanced magnetic resonance (MR). Significant coagulative necrosis was obtained in all patients after scheduled HIFU ablations; the volume ablation ratio was 86.7% ± 12.5% (range 65-100%). Complete tumour necrosis was achieved in all patients receiving curative HIFU ablation. No major complications were encountered. No patients died of local tumour progression during follow-up. US-guided HIFU ablation may be a safe and effective minimally invasive technique for the local treatment of primary malignant tumours of the bony pelvis.

  7. Visualization of spiral ganglion neurites within the scala tympani with a cochlear implant in situ

    PubMed Central

    Chikar, Jennifer A.; Batts, Shelley A.; Pfingst, Bryan E.; Raphael, Yehoash

    2009-01-01

    Current cochlear histology methods do not allow in situ processing of cochlear implants. The metal components of the implant preclude standard embedding and mid-modiolar sectioning, and whole mounts do not have the spatial resolution needed to view the implant within the scala tympani. One focus of recent auditory research is the regeneration of structures within the cochlea, particularly the ganglion cells and their processes, and there are multiple potential benefits to cochlear implant users from this work. To facilitate experimental investigations of auditory nerve regeneration performed in conjunction with cochlear implantation, it is critical to visualize the cochlear tissue and the implant together to determine if the nerve has made contact with the implant. This paper presents a novel histological technique that enables simultaneous visualization of the in situ cochlear implant and neurofilament – labeled nerve processes within the scala tympani, and the spatial relationship between them. PMID:19428528

  8. Visualization of spiral ganglion neurites within the scala tympani with a cochlear implant in situ.

    PubMed

    Chikar, Jennifer A; Batts, Shelley A; Pfingst, Bryan E; Raphael, Yehoash

    2009-05-15

    Current cochlear histology methods do not allow in situ processing of cochlear implants. The metal components of the implant preclude standard embedding and mid-modiolar sectioning, and whole mounts do not have the spatial resolution needed to view the implant within the scala tympani. One focus of recent auditory research is the regeneration of structures within the cochlea, particularly the ganglion cells and their processes, and there are multiple potential benefits to cochlear implant users from this work. To facilitate experimental investigations of auditory nerve regeneration performed in conjunction with cochlear implantation, it is critical to visualize the cochlear tissue and the implant together to determine if the nerve has made contact with the implant. This paper presents a novel histological technique that enables simultaneous visualization of the in situ cochlear implant and neurofilament-labeled nerve processes within the scala tympani, and the spatial relationship between them.

  9. Topics in Modeling of Cochlear Dynamics: Computation, Response and Stability Analysis

    NASA Astrophysics Data System (ADS)

    Filo, Maurice G.

    This thesis touches upon several topics in cochlear modeling. Throughout the literature, mathematical models of the cochlea vary according to the degree of biological realism to be incorporated. This thesis casts the cochlear model as a continuous space-time dynamical system using operator language. This framework encompasses a wider class of cochlear models and makes the dynamics more transparent and easier to analyze before applying any numerical method to discretize space. In fact, several numerical methods are investigated to study the computational efficiency of the finite dimensional realizations in space. Furthermore, we study the effects of the active gain perturbations on the stability of the linearized dynamics. The stability analysis is used to explain possible mechanisms underlying spontaneous otoacoustic emissions and tinnitus. Dynamic Mode Decomposition (DMD) is introduced as a useful tool to analyze the response of nonlinear cochlear models. Cochlear response features are illustrated using DMD which has the advantage of explicitly revealing the spatial modes of vibrations occurring in the Basilar Membrane (BM). Finally, we address the dynamic estimation problem of BM vibrations using Extended Kalman Filters (EKF). Due to the limitations of noninvasive sensing schemes, such algorithms are inevitable to estimate the dynamic behavior of a living cochlea.

  10. 1. GENERAL VIEW FROM BONY PILE LOOKING SOUTH. WASH HOUSE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. GENERAL VIEW FROM BONY PILE LOOKING SOUTH. WASH HOUSE IN LEFT BACKGROUND. TIPPLE AND CLEANING PLANT TO RIGHT. IN CENTER IS A TANK USED FOR TREATING MINE REFUSE AND ACID RUNOFF. - Eureka No. 40, Tipple & Cleaning Plant, East of State Route 56, north of Little Paint Creek, Scalp Level, Cambria County, PA

  11. Close-field electroporation gene delivery using the cochlear implant electrode array enhances the bionic ear.

    PubMed

    Pinyon, Jeremy L; Tadros, Sherif F; Froud, Kristina E; Y Wong, Ann C; Tompson, Isabella T; Crawford, Edward N; Ko, Myungseo; Morris, Renée; Klugmann, Matthias; Housley, Gary D

    2014-04-23

    The cochlear implant is the most successful bionic prosthesis and has transformed the lives of people with profound hearing loss. However, the performance of the "bionic ear" is still largely constrained by the neural interface itself. Current spread inherent to broad monopolar stimulation of the spiral ganglion neuron somata obviates the intrinsic tonotopic mapping of the cochlear nerve. We show in the guinea pig that neurotrophin gene therapy integrated into the cochlear implant improves its performance by stimulating spiral ganglion neurite regeneration. We used the cochlear implant electrode array for novel "close-field" electroporation to transduce mesenchymal cells lining the cochlear perilymphatic canals with a naked complementary DNA gene construct driving expression of brain-derived neurotrophic factor (BDNF) and a green fluorescent protein (GFP) reporter. The focusing of electric fields by particular cochlear implant electrode configurations led to surprisingly efficient gene delivery to adjacent mesenchymal cells. The resulting BDNF expression stimulated regeneration of spiral ganglion neurites, which had atrophied 2 weeks after ototoxic treatment, in a bilateral sensorineural deafness model. In this model, delivery of a control GFP-only vector failed to restore neuron structure, with atrophied neurons indistinguishable from unimplanted cochleae. With BDNF therapy, the regenerated spiral ganglion neurites extended close to the cochlear implant electrodes, with localized ectopic branching. This neural remodeling enabled bipolar stimulation via the cochlear implant array, with low stimulus thresholds and expanded dynamic range of the cochlear nerve, determined via electrically evoked auditory brainstem responses. This development may broadly improve neural interfaces and extend molecular medicine applications.

  12. Evidence of across-channel processing for spectral-ripple discrimination in cochlear implant listeners.

    PubMed

    Won, Jong Ho; Jones, Gary L; Drennan, Ward R; Jameyson, Elyse M; Rubinstein, Jay T

    2011-10-01

    Spectral-ripple discrimination has been used widely for psychoacoustical studies in normal-hearing, hearing-impaired, and cochlear implant listeners. The present study investigated the perceptual mechanism for spectral-ripple discrimination in cochlear implant listeners. The main goal of this study was to determine whether cochlear implant listeners use a local intensity cue or global spectral shape for spectral-ripple discrimination. The effect of electrode separation on spectral-ripple discrimination was also evaluated. Results showed that it is highly unlikely that cochlear implant listeners depend on a local intensity cue for spectral-ripple discrimination. A phenomenological model of spectral-ripple discrimination, as an "ideal observer," showed that a perceptual mechanism based on discrimination of a single intensity difference cannot account for performance of cochlear implant listeners. Spectral modulation depth and electrode separation were found to significantly affect spectral-ripple discrimination. The evidence supports the hypothesis that spectral-ripple discrimination involves integrating information from multiple channels. © 2011 Acoustical Society of America

  13. Some considerations concerning cochlear implantation in IFACF-ORL

    PubMed Central

    Hainarosie, M; Zainea, V; Serban, S; Georgescu, MG; Hainarosie, R; Marinescu, A; Georgescu, G

    2014-01-01

    The article analyzes the patients who have received a cochlear implant at “Prof. Dr. Dorin Hociota” Institute of Phonoaudiology and Functional ENT Surgery, Bucharest, over a period of 13 years, from the beginning of this program in the year 2000. It presents the types of devices used, the particularities of the patients, the surgical techniques and the outcome, critically analyzing the complications encountered. The authors’ comments on the selection of patient protocol, surgical intraoperative challenges and cochlear implant technologies and capabilities are presented. PMID:25870683

  14. Association between scapula bony morphology and snapping scapula syndrome.

    PubMed

    Spiegl, Ulrich J; Petri, Maximilian; Smith, Sean W; Ho, Charles P; Millett, Peter J

    2015-08-01

    Scapular incongruity has been described as a contributing factor to the development of snapping scapula syndrome (SSS). The purpose of this retrospective case-control study was to determine the association between scapula bony morphology on magnetic resonance imaging (MRI) and the diagnosis of SSS. Bony morphologies of the scapula were evaluated on MRI scans of 26 patients with SSS and 19 patients with non-SSS pathologies. The medial scapula corpus angle (MSCA) was measured on axial MRI sequences. Scapulae were categorized as straight, S shaped, or concave. Two independent observers performed the measurements. Interobserver and intraobserver agreements of MSCA measurements were determined with intraclass correlation coefficients. Axial scapula bony morphology identified 28 scapulae of the straight type, 14 S-shaped scapulae, and 5 concave scapulae. All 5 concave scapulae had confirmed SSS. Measurement of the MSCA showed excellent interobserver agreement of 0.80 (95% confidence interval [CI], 0.67 to 0.89) and intraobserver agreement of 0.70 (95% CI, 0.52 to 0.82). There were significant differences in the mean MSCAs between shoulders with SSS (14.4° ± 19.3°) and non-SSS shoulders (-3.3° ± 15.3°, P = .001). The odds ratio was 8.4 (95% CI, 2.2 to 31.8) for positive MSCA and SSS. The scapulothoracic distance was significantly decreased in the SSS group (14.9 ± 5.8 mm) compared with the non-SSS patients (24.0 ± 6.7 mm, P < .001). Anterior angulation of the medial scapula in the axial plane was associated with SSS. Patients with a concave-shaped scapula and a positive MSCA have a 12-fold increased risk of SSS. The MSCA may prove helpful in determining the location and amount of scapular resection needed for patients with SSS. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  15. Protective role of hydrogen sulfide against noise-induced cochlear damage: a chronic intracochlear infusion model.

    PubMed

    Li, Xu; Mao, Xiao-Bo; Hei, Ren-Yi; Zhang, Zhi-Bin; Wen, Li-Ting; Zhang, Peng-Zhi; Qiu, Jian-Hua; Qiao, Li

    2011-01-01

    A reduction in cochlear blood flow plays an essential role in noise-induced hearing loss (NIHL). The timely regulation of cochlear perfusion determines the progression and prognosis of NIHL. Hydrogen sulfide (H(2)S) has attracted increasing interest as a vasodilator in cardiovascular systems. This study identified the role of H(2)S in cochlear blood flow regulation and noise protection. The gene and protein expression of the H(2)S synthetase cystathionine-γ-lyase (CSE) in the rat cochlea was examined using immunofluorescence and real-time PCR. Cochlear CSE mRNA levels varied according to the duration of noise exposure. A chronic intracochlear infusion model was built and artificial perilymph (AP), NaHS or DL-propargylglycine (PPG) were locally administered. Local sodium hydrosulfide (NaHS) significantly increased cochlear perfusion post-noise exposure. Cochlear morphological damage and hearing loss were alleviated in the NaHS group as measured by conventional auditory brainstem response (ABR), cochlear scanning electron microscope (SEM) and outer hair cell (OHC) count. The highest percentage of OHC loss occurred in the PPG group. Our results suggest that H(2)S plays an important role in the regulation of cochlear blood flow and the protection against noise. Further studies may identify a new preventive and therapeutic perspective on NIHL and other blood supply-related inner ear diseases.

  16. Outcomes and special considerations of cochlear implantation in waardenburg syndrome.

    PubMed

    Kontorinis, Georgios; Lenarz, Thomas; Giourgas, Alexandros; Durisin, Martin; Lesinski-Schiedat, Anke

    2011-08-01

    The objective of this study was a state-of-the-art analysis of cochlear implantation in patients with Waardenburg syndrome (WS). Twenty-five patients with WS treated with cochlear implants in our department from 1990 to 2010. The 25 patients with WS underwent 35 cochlear implantations. Hearing outcome was evaluated using HSM sentence test in 65 dB in quiet, Freiburg Monosyllabic Test, and categories of auditory performance for children and compared with that of a control group. Anatomic abnormalities of the inner ear were examined using magnetic resonance imaging and computed tomography of the temporal bones. The mean follow-up time was 8.3 years (range, 0.3-18.3 yr). The majority achieved favorable postimplantation performance with mean HSM scores of 75.3% (range, 22.6%-99%) and Freiburg Monosyllabic Test scores of 67.8% (range, 14%-95%). However, in 4 cases, the results were less satisfactory. The comparison with the control group did not reveal any statistical significance (p = 0.56). In 6 patients (24%), behavioral disorders caused temporary difficulties during the rehabilitation procedure. Except of isolated large vestibule in 1 patient, the radiological assessment of the 50 temporal bones did not reveal any temporal bone abnormalities. Most patients with WS performed well with cochlear implants. However, WS is related to behavioral disorders that may cause temporary rehabilitation difficulties. Finally, temporal bone malformations that could affect cochlear implantation are notcharacteristic of WS.

  17. Salicylate enables cochlear arachidonic-acid-sensitive NMDA receptor responses.

    PubMed

    Ruel, Jérôme; Chabbert, Christian; Nouvian, Régis; Bendris, Rim; Eybalin, Michel; Leger, Claude Louis; Bourien, Jérôme; Mersel, Marcel; Puel, Jean-Luc

    2008-07-16

    Currently, many millions of people treated for various ailments receive high doses of salicylate. Consequently, understanding the mechanisms by which salicylate induces tinnitus is an important issue for the research community. Behavioral testing in rats have shown that tinnitus induced by salicylate or mefenamate (both cyclooxygenase blockers) are mediated by cochlear NMDA receptors. Here we report that the synapses between the sensory inner hair cells and the dendrites of the cochlear spiral ganglion neurons express NMDA receptors. Patch-clamp recordings and two-photon calcium imaging demonstrated that salicylate and arachidonate (a substrate of cyclooxygenase) enabled the calcium flux and the neural excitatory effects of NMDA on cochlear spiral ganglion neurons. Salicylate also increased the arachidonate content of the whole cochlea in vivo. Single-unit recordings of auditory nerve fibers in adult guinea pig confirmed the neural excitatory effect of salicylate and the blockade of this effect by NMDA antagonist. These results suggest that salicylate inhibits cochlear cyclooxygenase, which increased levels of arachidonate. The increased levels of arachidonate then act on NMDA receptors to enable NMDA responses to glutamate that inner hair cells spontaneously release. This new pharmacological profile of salicylate provides a molecular mechanism for the generation of tinnitus at the periphery of the auditory system.

  18. Vocal singing by prelingually-deafened children with cochlear implants.

    PubMed

    Xu, Li; Zhou, Ning; Chen, Xiuwu; Li, Yongxin; Schultz, Heather M; Zhao, Xiaoyan; Han, Demin

    2009-09-01

    The coarse pitch information in cochlear implants might hinder the development of singing in prelingually-deafened pediatric users. In the present study, seven prelingually-deafened children with cochlear implants (5.4-12.3 years old) sang one song that was the most familiar to him or her. The control group consisted of 14 normal-hearing children (4.1-8.0 years old). The fundamental frequencies (F0) of each note in the recorded songs were extracted. The following five metrics were computed based on the reference music scores: (1) F0 contour direction of the adjacent notes, (2) F0 compression ratio of the entire song, (3) mean deviation of the normalized F0 across the notes, (4) mean deviation of the pitch intervals, and (5) standard deviation of the note duration differences. Children with cochlear implants showed significantly poorer performance in the pitch-based assessments than the normal-hearing children. No significant differences were seen between the two groups in the rhythm-based measure. Prelingually-deafened children with cochlear implants have significant deficits in singing due to their inability to manipulate pitch in the correct directions and to produce accurate pitch height. Future studies with a large sample size are warranted in order to account for the large variability in singing performance.

  19. Ultrasound Produces Extensive Brain Activation via a Cochlear Pathway.

    PubMed

    Guo, Hongsun; Hamilton, Mark; Offutt, Sarah J; Gloeckner, Cory D; Li, Tianqi; Kim, Yohan; Legon, Wynn; Alford, Jamu K; Lim, Hubert H

    2018-06-06

    Ultrasound (US) can noninvasively activate intact brain circuits, making it a promising neuromodulation technique. However, little is known about the underlying mechanism. Here, we apply transcranial US and perform brain mapping studies in guinea pigs using extracellular electrophysiology. We find that US elicits extensive activation across cortical and subcortical brain regions. However, transection of the auditory nerves or removal of cochlear fluids eliminates the US-induced activity, revealing an indirect auditory mechanism for US neural activation. Our findings indicate that US activates the ascending auditory system through a cochlear pathway, which can activate other non-auditory regions through cross-modal projections. This cochlear pathway mechanism challenges the idea that US can directly activate neurons in the intact brain, suggesting that future US stimulation studies will need to control for this effect to reach reliable conclusions. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. Restudy of malformations of the internal auditory meatus, cochlear nerve canal and cochlear nerve.

    PubMed

    Li, Youjin; Yang, Jun; Liu, Jinfen; Wu, Hao

    2015-07-01

    The present study aims to restudy the correlation between the internal auditory meatus (IAM), the cochlear nerve canal (CNC), the cochlear nerve (CN) and inner ear malformations. In this retrospective study design, the abnormal diameter of the IAM, CNC and CN in patients with any kind of inner ear malformations was evaluated using multi-slice spiral computed tomography (MSCT) (37 patients) and magnetic resonance imaging (MRI) (18 patients). Of 37 MSCT-diagnosed patients, 2 had IAM atresia, 11 IAM stenosis, 22 enlarged IAM, and 2 normal IAM with an abnormal CN. MRI diagnoses of 18 patients revealed 8 cases of aplastic CN, 6 hypoplastic CN, and 4 normal CN. CNC stenosis was associated with CN hypoplasia (P < 0.001). Patients with absent or stenotic IAM had less CN development than those with normal or enlarged IAM (P = 0.001). We propose a modification of the existing classification systems with a view to distinguishing malformations of the IAM, CNC and CN.

  1. Cochlear implantation in chronic demyelinating inflammatory polyneuropathy.

    PubMed

    Mowry, Sarah E; King, Sarah

    2017-03-01

    To describe a case of chronic inflammatory demyelinating polyneuropathy (CDIP) with bilateral sudden sensorineural hearing loss who subsequently benefited from unilateral cochlear implantation. case history review and review of the literature for the terms CDIP, hearing loss, cochleovestibular dysfunction, and cochlear implantation. A 49-year-old woman presented with bilateral rapidly progressive sensorineural hearing loss (SNHL) 1 month after an upper respiratory tract infection. Hearing loss was not responsive to high-dose steroids and there were no other laboratory abnormalities or physical findings. Within 1 month, she developed ascending motor palsy, requiring long-term ventilator support. This neurologic condition was diagnosed as CDIP and she was successfully treated with plasmapheresis and intravenous immunoglobulin. Her hearing never recovered. At the time of cochlear implant, she had no response at the limits of the audiometer and obtained 0% on AzBio testing. No ABR could be recorded preoperatively. She underwent uneventful cochlear implantation with a perimodilar electrode. One year after activation, she had a PTA of 20 dB and 40% on AzBio sentence testing. Her eABR demonstrated a neuropathy pattern. Only two other cases of CDIP associated with dysfunction of the eighth nerve have been described, and neither had documented profound hearing loss. Severe SNHL associated with CDIP is rare. Although this patient has good access to sound, speech discrimination is poor at 1-year post implantation. This outcome may be due to incomplete recovery of myelination of the eighth nerve. Other possibilities include loss of peripheral nerve fibers due to the initial viral upper respiratory infection, which may lead to less neural substrate to stimulate.

  2. Bony increased-offset reversed shoulder arthroplasty: minimizing scapular impingement while maximizing glenoid fixation.

    PubMed

    Boileau, Pascal; Moineau, Grégory; Roussanne, Yannick; O'Shea, Kieran

    2011-09-01

    Scapular notching, prosthetic instability, limited shoulder rotation and loss of shoulder contour are associated with conventional medialized design reverse shoulder arthroplasty. Prosthetic (ie, metallic) lateralization increases torque at the baseplate-glenoid interface potentially leading to failure. We asked whether bony lateralization of reverse shoulder arthroplasty would avoid the problems caused by humeral medialization without increasing torque or shear force applied to the glenoid component. We prospectively followed 42 patients with rotator cuff deficiency treated with bony increased-offset reverse shoulder arthroplasty. A cylinder of autologous cancellous bone graft, harvested from the humeral head, was placed between the reamed glenoid surface and baseplate. Graft and baseplate fixation was achieved using a lengthened central peg (25 mm) and four screws. Patients underwent clinical, radiographic, and CT assessment at a minimum of 2 years after surgery. The humeral graft incorporated completely in 98% of cases (41 of 42) and partially in one. At a mean of 28 months postoperatively, no graft resorption, glenoid loosening, or postoperative instability was observed. Inferior scapular notching occurred in 19% (eight of 42). The absolute Constant-Murley score improved from 31 to 67. Thirty-six patients (86%) were able to internally rotate sufficiently to reach their back over the sacrum. Grafting of the glenoid surface during reverse shoulder arthroplasty effectively creates a long-necked scapula, providing the benefits of lateralization. Bony increased-offset reverse shoulder arthroplasty is associated with low rates of inferior scapular notching, improved shoulder rotation, no prosthetic instability and improved shoulder contour. In contrast to metallic lateralization, bony lateralization has the advantage of maintaining the prosthetic center of rotation at the prosthesis-bone interface, thus minimizing torque on the glenoid component. Level IV

  3. Hearing rehabilitation with a binaural cochlear implant in a patient with Erdheim-Chester disease.

    PubMed

    Querat, Charlotte; Thai-Van, Hung; Durand, Denis Vital; Cotton, François; Gallego, Stéphane; Truy, Eric

    2015-09-01

    Erdheim-Chester disease (ECD) is a rare non-Langerhans form of histiocytosis. This paper reports an exceptional case of bilateral neural involvement, responsible for profound hearing loss. Bilateral cochlear implantation was performed. We present a 57-year-old man affected by ECD with profound bilateral hearing loss. The patient underwent cochlear implantation with a binaural Digisonic(®) cochlear implant, 7 years after the initial diagnosis. Speech intelligibility rose to a plateau after about 6 months of cochlear implant use. The average outcome of speech intelligibility over time was 55% for dissyllabic words without lip reading, and 70% for sentences. Perception score decreased before the patient died from ECD. A description of the ECD and its otological manifestations is presented. This paper reports the effective hearing rehabilitation of profound bilateral hearing loss by the means of a binaural Digisonic(®) cochlear implant.

  4. An Electromechanical Model for the Cochlear Microphonic

    NASA Astrophysics Data System (ADS)

    Teal, Paul D.; Lineton, Ben; Elliott, Stephen J.

    2011-11-01

    The first of the many electrical signals generated in the ear, nerves and brain as a response to a sound incident on the ear is the cochlear microphonic (CM). The CM is generated by the hair cells of the cochlea, primarily the outer hairs cells. The potentials of this signal are a nonlinear filtered version of the acoustic pressure at the tympanic membrane. The CM signal has been used very little in recent years for clinical audiology and audiological research. This is because of uncertainty in interpreting the CM signal as a diagnostic measure, and also because of the difficulty of obtaining the signal, which has usually required the use of a transtympanic electrode. There are however, several potential clinical and research applications for acquisition of the CM. To promote understanding of the CM, and potential clinical application, a model is presented which can account for the generation of the cochlear microphonic signal. The model incorporates micro-mechanical and macro-mechanical aspects of previously published models of the basilar membrane and reticular lamina, as well as cochlear fluid mechanics, piezoelectric activity and capacitance of the outer hair cells. It also models the electrical coupling of signals along the scalae.

  5. Children with Cochlear Implants in Australia: Educational Settings, Supports, and Outcomes

    ERIC Educational Resources Information Center

    Punch, Renee; Hyde, Merv

    2010-01-01

    This Australian study examined the communication, academic, and social outcomes of pediatric cochlear implantation from the perspectives of teachers working with children with cochlear implants. The children were aged from 1 to 18 years and attended a range of educational settings in early intervention, primary, and secondary schooling. One…

  6. Benefits and Risks of Cochlear Implants

    MedlinePlus

    ... The cochlear implant stimulates the nerves directly with electrical currents. Although this stimulation appears to be safe, the long term effect of these electrical currents on the nerves is unknown. May not ...

  7. Sequential Bilateral Cochlear Implantation in a Patient with Bilateral Meniere’s Disease

    PubMed Central

    Holden, Laura K.; Neely, J. Gail; Gotter, Brenda D.; Mispagel, Karen M.; Firszt, Jill B.

    2012-01-01

    This case study describes a 45 year old female with bilateral, profound sensorineural hearing loss due to Meniere’s disease. She received her first cochlear implant in the right ear in 2008 and the second cochlear implant in the left ear in 2010. The case study examines the enhancement to speech recognition, particularly in noise, provided by bilateral cochlear implants. Speech recognition tests were administered prior to obtaining the second implant and at a number of test intervals following activation of the second device. Speech recognition in quiet and noise as well as localization abilities were assessed in several conditions to determine bilateral benefit and performance differences between ears. The results of the speech recognition testing indicated a substantial improvement in the patient’s ability to understand speech in noise and her ability to localize sound when using bilateral cochlear implants compared to using a unilateral implant or an implant and a hearing aid. In addition, the patient reported considerable improvement in her ability to communicate in daily life when using bilateral implants versus a unilateral implant. This case suggests that cochlear implantation is a viable option for patients who have lost their hearing to Meniere’s disease even when a number of medical treatments and surgical interventions have been performed to control vertigo. In the case presented, bilateral cochlear implantation was necessary for this patient to communicate successfully at home and at work. PMID:22463939

  8. Preventing hearing damage using topical dexamethasone during reversible cochlear ischemia: an animal model.

    PubMed

    Morawski, Krzysztof; Telischi, Fred F; Bohorquez, Jorge; Niemczyk, Kazimierz

    2009-09-01

    Local application of dexamethasone to the round window (RW) niche prevents cochlear damage caused by local reversible ischemia. Cochlear ischemia induced by internal auditory artery (IAA) compression/stretching is thought to cause postoperative sensory hearing loss after attempted hearing preservation removal of acoustic neuroma tumors. Dexamethasone administered to the RW niche traveling through the membrane to the cochlear fluids may prevent ischemic damage. Ten young albino rabbits were used for this study. Ischemic episodes were induced by compressing the IAA. Laser Doppler cochlear blood flow was measured using a probe positioned at the RW niche. Transtympanic electrocochleography was measured at 4, 8, and 12 kHz. In 5 test ears, dexamethasone was administered topically at the RW for approximately 50 minutes before the IAA compressions, whereas in 5 control ears, saline was applied in the same way. Each ear underwent one 10-minute IAA compression with a 60-minute postischemic period of transtympanic electrocochleography monitoring. In both control- and dexamethasone-treated ears, ischemic episodes measured by Laser Doppler cochlear blood flow were comparable. Fifty minutes after IAA decompression, in dexamethasone-pretreated ears, cochlear microphonic and compound action potential amplitudes at all test frequencies were 10 to 15% less reduced than those in control ears. Compound action potential latencies in dexamethasone-pretreated ears resulted in shorter latency delay than in control ears. The RW seems to be an efficacious route for the administration of dexamethasone into the inner ear. Dexamethasone showed a protective effect on cochlear function after local ischemia. Transtympanic electrocochleography was found to be a sufficient and effective tool in monitoring hearing.

  9. 3D optical coherence tomography image registration for guiding cochlear implant insertion

    NASA Astrophysics Data System (ADS)

    Cheon, Gyeong-Woo; Jeong, Hyun-Woo; Chalasani, Preetham; Chien, Wade W.; Iordachita, Iulian; Taylor, Russell; Niparko, John; Kang, Jin U.

    2014-03-01

    In cochlear implant surgery, an electrode array is inserted into the cochlear canal to restore hearing to a person who is profoundly deaf or significantly hearing impaired. One critical part of the procedure is the insertion of the electrode array, which looks like a thin wire, into the cochlear canal. Although X-ray or computed tomography (CT) could be used as a reference to evaluate the pathway of the whole electrode array, there is no way to depict the intra-cochlear canal and basal turn intra-operatively to help guide insertion of the electrode array. Optical coherent tomography (OCT) is a highly effective way of visualizing internal structures of cochlea. Swept source OCT (SSOCT) having center wavelength of 1.3 micron and 2D Galvonometer mirrors was used to achieve 7-mm depth 3-D imaging. Graphics processing unit (GPU), OpenGL, C++ and C# were integrated for real-time volumetric rendering simultaneously. The 3D volume images taken by the OCT system were assembled and registered which could be used to guide a cochlear implant. We performed a feasibility study using both dry and wet temporal bones and the result is presented.

  10. Trunk dental tissue evolved independently from underlying dermal bony plates but is associated with surface bones in living odontode-bearing catfish

    PubMed Central

    2017-01-01

    Although oral dental tissue is a vertebrate attribute, trunk dental tissue evolved in several extinct vertebrate lineages but is rare among living species. The question of which processes trigger dental-tissue formation in the trunk remains open, and would shed light on odontogenesis evolution. Extra-oral dental structures (odontodes) in the trunk are associated with underlying dermal bony plates, leading us to ask whether the formation of trunk bony plates is necessary for trunk odontodes to emerge. To address this question, we focus on Loricarioidei: an extant, highly diverse group of catfish whose species all have odontodes. We examined the location and cover of odontodes and trunk dermal bony plates for all six loricarioid families and 17 non-loricarioid catfish families for comparison. We inferred the phylogeny of Loricarioidei using a new 10-gene dataset, eight time-calibration points, and noise-reduction techniques. Based on this phylogeny, we reconstructed the ancestral states of odontode and bony plate cover, and find that trunk odontodes emerged before dermal bony plates in Loricarioidei. Yet we discovered that when bony plates are absent, other surface bones are always associated with odontodes, suggesting a link between osteogenic and odontogenic developmental pathways, and indicating a remarkable trunk odontogenic potential in Loricarioidei. PMID:29046381

  11. Acute hyperfibrinogenemia impairs cochlear blood flow and hearing function in guinea pigs in vivo.

    PubMed

    Ihler, Fritz; Strieth, Sebastian; Pieri, Nicos; Göhring, Peter; Canis, Martin

    2012-03-01

    Impairment of microcirculation is a possible cause of sudden sensorineural hearing loss (SSNHL). Fibrinogen is known as a risk factor for both microvascular dysfunction and SSNHL. Therefore, the aim of this study was to investigate the effect of elevated serum levels of fibrinogen on cochlear blood flow and hearing function in vivo. One group of guinea pigs received two consecutive injections of 100 mg fibrinogen while a control group received equimolar doses of albumin. Measurements of cochlear microcirculation by intravital microscopy and of hearing thresholds by auditory brainstem response (ABR) recordings were carried out before, after first and after second injection. Ten healthy guinea pigs were randomly assigned to a treatment group or a control group of five animals each. Serum fibrinogen levels were elevated after the first and second injections of fibrinogen compared to basal values and control group respectively. Increasing levels of fibrinogen were paralleled by decreasing cochlear blood flow as well as increasing hearing thresholds. Hearing threshold correlated negatively with cochlear blood flow. The effect of microcirculatory impairment on hearing function could be explained by a malfunction of the cochlear amplifier. Further investigation is needed to quantify cochlear potentials under elevated serum fibrinogen levels.

  12. Modeling and segmentation of intra-cochlear anatomy in conventional CT

    NASA Astrophysics Data System (ADS)

    Noble, Jack H.; Rutherford, Robert B.; Labadie, Robert F.; Majdani, Omid; Dawant, Benoit M.

    2010-03-01

    Cochlear implant surgery is a procedure performed to treat profound hearing loss. Since the cochlea is not visible in surgery, the physician uses anatomical landmarks to estimate the pose of the cochlea. Research has indicated that implanting the electrode in a particular cavity of the cochlea, the scala tympani, results in better hearing restoration. The success of the scala tympani implantation is largely dependent on the point of entry and angle of electrode insertion. Errors can occur due to the imprecise nature of landmark-based, manual navigation as well as inter-patient variations between scala tympani and the anatomical landmarks. In this work, we use point distribution models of the intra-cochlear anatomy to study the inter-patient variations between the cochlea and the typical anatomic landmarks, and we implement an active shape model technique to automatically localize intra-cochlear anatomy in conventional CT images, where intra-cochlear structures are not visible. This fully automatic segmentation could aid the surgeon to choose the point of entry and angle of approach to maximize the likelihood of scala tympani insertion, resulting in more substantial hearing restoration.

  13. Evaluation of a cochlear-implant processing strategy incorporating phantom stimulation and asymmetric pulses

    PubMed Central

    Monstrey, Jolijn; Deeks, John M.; Macherey, Olivier

    2014-01-01

    Objective To evaluate a speech-processing strategy in which the lowest frequency channel is conveyed using an asymmetric pulse shape and “phantom stimulation”, where current is injected into one intra-cochlear electrode and where the return current is shared between an intra-cochlear and an extra-cochlear electrode. This strategy is expected to provide more selective excitation of the cochlear apex, compared to a standard strategy where the lowest-frequency channel is conveyed by symmetric pulses in monopolar mode. In both strategies all other channels were conveyed by monopolar stimulation. Design Within-subjects comparison between the two strategies. Four experiments: (1) discrimination between the strategies, controlling for loudness differences, (2) consonant identification, (3) recognition of lowpass-filtered sentences in quiet, (4) sentence recognition in the presence of a competing speaker. Study sample Eight users of the Advanced Bionics CII/Hi-Res 90k cochlear implant. Results Listeners could easily discriminate between the two strategies but no consistent differences in performance were observed. Conclusions The proposed method does not improve speech perception, at least in the short term. PMID:25358027

  14. Evaluation of a cochlear-implant processing strategy incorporating phantom stimulation and asymmetric pulses.

    PubMed

    Carlyon, Robert P; Monstrey, Jolijn; Deeks, John M; Macherey, Olivier

    2014-12-01

    To evaluate a speech-processing strategy in which the lowest frequency channel is conveyed using an asymmetric pulse shape and "phantom stimulation", where current is injected into one intra-cochlear electrode and where the return current is shared between an intra-cochlear and an extra-cochlear electrode. This strategy is expected to provide more selective excitation of the cochlear apex, compared to a standard strategy where the lowest-frequency channel is conveyed by symmetric pulses in monopolar mode. In both strategies all other channels were conveyed by monopolar stimulation. Within-subjects comparison between the two strategies. Four experiments: (1) discrimination between the strategies, controlling for loudness differences, (2) consonant identification, (3) recognition of lowpass-filtered sentences in quiet, (4) sentence recognition in the presence of a competing speaker. Eight users of the Advanced Bionics CII/Hi-Res 90k cochlear implant. Listeners could easily discriminate between the two strategies but no consistent differences in performance were observed. The proposed method does not improve speech perception, at least in the short term.

  15. Speech Intelligibility and Prosody Production in Children with Cochlear Implants

    PubMed Central

    Chin, Steven B.; Bergeson, Tonya R.; Phan, Jennifer

    2012-01-01

    Objectives The purpose of the current study was to examine the relation between speech intelligibility and prosody production in children who use cochlear implants. Methods The Beginner's Intelligibility Test (BIT) and Prosodic Utterance Production (PUP) task were administered to 15 children who use cochlear implants and 10 children with normal hearing. Adult listeners with normal hearing judged the intelligibility of the words in the BIT sentences, identified the PUP sentences as one of four grammatical or emotional moods (i.e., declarative, interrogative, happy, or sad), and rated the PUP sentences according to how well they thought the child conveyed the designated mood. Results Percent correct scores were higher for intelligibility than for prosody and higher for children with normal hearing than for children with cochlear implants. Declarative sentences were most readily identified and received the highest ratings by adult listeners; interrogative sentences were least readily identified and received the lowest ratings. Correlations between intelligibility and all mood identification and rating scores except declarative were not significant. Discussion The findings suggest that the development of speech intelligibility progresses ahead of prosody in both children with cochlear implants and children with normal hearing; however, children with normal hearing still perform better than children with cochlear implants on measures of intelligibility and prosody even after accounting for hearing age. Problems with interrogative intonation may be related to more general restrictions on rising intonation, and the correlation results indicate that intelligibility and sentence intonation may be relatively dissociated at these ages. PMID:22717120

  16. Spelling in Written Stories by School-Age Children with Cochlear Implants

    ERIC Educational Resources Information Center

    Straley, Sara G.; Werfel, Krystal L.; Hendricks, Alison Eisel

    2016-01-01

    This study evaluated the spelling of 3rd to 6th grade children with cochlear implants in written stories. Spelling was analysed using traditional correct/incorrect scoring as well as the Spelling Sensitivity Score, which provides linguistic information about spelling attempts. Children with cochlear implants spelled 86 per cent of words in stories…

  17. Ethnic Differences in Bony Hip Morphology in a Cohort of 445 Professional Male Soccer Players.

    PubMed

    Mosler, Andrea B; Crossley, Kay M; Waarsing, Jan H; Jomaah, Nabil; Weir, Adam; Hölmich, Per; Agricola, Rintje

    2016-11-01

    Participation in high-impact athletic activities has recently been associated with a higher prevalence of cam deformity. Bony hip morphology has also emerged as an important factor in the development of hip osteoarthritis. However, it is unknown whether bony morphology differs between ethnicities in athletes participating in high-impact sports. To investigate whether the prevalence of specific bony hip morphological abnormalities differed between professional male soccer players of diverse ethnic backgrounds. Cross-sectional study; Level of evidence, 3. Professional male soccer players from an entire league attending preparticipation screening were invited to participate in this study. Ethnicity was registered, and standardized radiographs of anteroposterior pelvic and Dunn views were obtained. Cam and pincer deformity, and acetabular dysplasia were quantified using the alpha angle, triangular index, and lateral center-edge angle (LCEA). Regression analyses with generalized estimating equations were used to determine prevalence differences in bony hip morphology. A total of 445 male soccer players (890 hips; mean age ± SD, 25 ± 4.9 years) participated in the study, representing the following ethnic groups: Arabic (59%), black (24%), Persian (7%), white (6%), East Asian (2%), and other (2%). The prevalence of cam deformity (alpha angle >60°) ranged from 57.5% to 71.7% across 4 of the groups, but East Asians had a significantly lower prevalence (18.8%; P ≤ .032). A large cam deformity (alpha angle >78°) was more prevalent in white (33.3%) compared with black soccer players (17.8%; P = .041) and was absent in East Asian players. Pincer deformity (LCEA >40°) was uncommon (3%) in all ethnicities. The prevalence of acetabular dysplasia (LCEA <20°) ranged from 8.0% to 16.7%, apart from the white group, in which prevalence was only 1.9% (P = .03). The prevalence of a cam deformity and acetabular dysplasia differed between ethnicities in this cohort of professional

  18. Lack of financial barriers to pediatric cochlear implantation: impact of socioeconomic status on access and outcomes.

    PubMed

    Chang, David T; Ko, Alvin B; Murray, Gail S; Arnold, James E; Megerian, Cliff A

    2010-07-01

    (1) To analyze if socioeconomic status influences access to cochlear implantation in an environment with adequate Medicaid reimbursement. (2) To determine the impact of socioeconomic status on outcomes after unilateral cochlear implantation. Retrospective cohort study. University Hospitals Case Medical Center and Rainbow Babies and Children's Hospital (tertiary referral center), Cleveland, Ohio. Pediatric patients (age range, newborn to 18 years) who received unilateral cochlear implantation during the period 1996 to 2008. Access to cochlear implantation after referral to a cochlear implant center, postoperative complications, compliance with follow-up appointments, and access to sequential bilateral cochlear implantation. A total of 133 pediatric patients were included in this study; 64 were Medicaid-insured patients and 69 were privately insured patients. There was no statistical difference in the odds of initial cochlear implantation, age at referral, or age at implantation between the 2 groups. The odds of prelingual Medicaid-insured patients receiving sequential bilateral cochlear implantation was less than half that of the privately insured group (odds ratio [OR], 0.43; P = .03). The odds of complications in Medicaid-insured children were almost 5-fold greater than the odds for privately insured children (OR, 4.6; P = .03). There were 10 complications in 51 Medicaid-insured patients (19.6%) as opposed to 3 in 61 privately insured patients (4.9%). Medicaid-insured patients missed substantially more follow-up appointments overall (35% vs 23%) and more consecutive visits (1.9 vs 1.1) compared with privately insured patients. In an environment with adequate Medicaid reimbursement, eligible children have equal access to cochlear implantation, regardless of socioeconomic background. However, lower socioeconomic background is associated with higher rates of postoperative complications, worse follow-up compliance, and lower rates of sequential bilateral implantation

  19. Bilateral cochlear implantation in the ferret: A novel animal model for behavioral studies

    PubMed Central

    Hartley, Douglas E.H.; Vongpaisal, Tara; Xu, Jin; Shepherd, Robert K.; King, Andrew J.; Isaiah, Amal

    2010-01-01

    Bilateral cochlear implantation has recently been introduced with the aim of improving both speech perception in background noise and sound localization. Although evidence suggests that binaural perception is possible with two cochlear implants, results in humans are variable. To explore potential contributing factors to these variable outcomes, we have developed a behavioral animal model of bilateral cochlear implantation in a novel species, the ferret. Although ferrets are ideally suited to psychophysical and physiological assessments of binaural hearing, cochlear implantation has not been previously described in this species. This paper describes the techniques of deafening with aminoglycoside administration, surgical implantation of an intracochlear array and chronic intracochlear electrical stimulation with monitoring for electrode integrity and efficacy of stimulation. Experiments have been presented elsewhere to show that the model can be used to study behavioral and electrophysiological measures of binaural hearing in chronically implanted animals. This paper demonstrates that cochlear implantation and chronic intracochlear electrical stimulation are both safe and effective in ferrets, opening up the possibility of using this model to study potential protective effects of bilateral cochlear implantation on the developing central auditory pathway. Since ferrets can be used to assess psychophysical and physiological aspects of hearing along with the structure of the auditory pathway in the same animals, we anticipate that this model will help develop novel neuroprosthetic therapies for use in humans. PMID:20576507

  20. Cochlear Implant Using Neural Prosthetics

    NASA Astrophysics Data System (ADS)

    Gupta, Shweta; Singh, Shashi kumar; Dubey, Pratik Kumar

    2012-10-01

    This research is based on neural prosthetic device. The oldest and most widely used of these electrical, and often computerized, devices is the cochlear implant, which has provided hearing to thousands of congenitally deaf people in this country. Recently, the use of the cochlear implant is expanding to the elderly, who frequently suffer major hearing loss. More cutting edge are artificial retinas, which are helping dozens of blind people see, and ìsmartî artificial arms and legs that amputees can maneuver by thoughts alone, and that feel more like real limbs.Research, which curiosity led to explore frog legs dancing during thunderstorms, a snail shapedorgan in the inner ear, and how various eye cells react to light, have fostered an understanding of how to ìtalkî to the nervous system. That understanding combined with the miniaturization of electronics and enhanced computer processing has enabled prosthetic devices that often can bridge the gap in nerve signaling that is caused by disease or injury.

  1. Using Evoked Potentials to Match Interaural Electrode Pairs with Bilateral Cochlear Implants

    PubMed Central

    Delgutte, Bertrand

    2007-01-01

    Bilateral cochlear implantation seeks to restore the advantages of binaural hearing to the profoundly deaf by providing binaural cues normally important for accurate sound localization and speech reception in noise. Psychophysical observations suggest that a key issue for the implementation of a successful binaural prosthesis is the ability to match the cochlear positions of stimulation channels in each ear. We used a cat model of bilateral cochlear implants with eight-electrode arrays implanted in each cochlea to develop and test a noninvasive method based on evoked potentials for matching interaural electrodes. The arrays allowed the cochlear location of stimulation to be independently varied in each ear. The binaural interaction component (BIC) of the electrically evoked auditory brainstem response (EABR) was used as an assay of binaural processing. BIC amplitude peaked for interaural electrode pairs at the same relative cochlear position and dropped with increasing cochlear separation in either direction. To test the hypothesis that BIC amplitude peaks when electrodes from the two sides activate maximally overlapping neural populations, we measured multiunit neural activity along the tonotopic gradient of the inferior colliculus (IC) with 16-channel recording probes and determined the spatial pattern of IC activation for each stimulating electrode. We found that the interaural electrode pairings that produced the best aligned IC activation patterns were also those that yielded maximum BIC amplitude. These results suggest that EABR measurements may provide a method for assigning frequency–channel mappings in bilateral implant recipients, such as pediatric patients, for which psychophysical measures of pitch ranking or binaural fusion are unavailable. PMID:17225976

  2. Using evoked potentials to match interaural electrode pairs with bilateral cochlear implants.

    PubMed

    Smith, Zachary M; Delgutte, Bertrand

    2007-03-01

    Bilateral cochlear implantation seeks to restore the advantages of binaural hearing to the profoundly deaf by providing binaural cues normally important for accurate sound localization and speech reception in noise. Psychophysical observations suggest that a key issue for the implementation of a successful binaural prosthesis is the ability to match the cochlear positions of stimulation channels in each ear. We used a cat model of bilateral cochlear implants with eight-electrode arrays implanted in each cochlea to develop and test a noninvasive method based on evoked potentials for matching interaural electrodes. The arrays allowed the cochlear location of stimulation to be independently varied in each ear. The binaural interaction component (BIC) of the electrically evoked auditory brainstem response (EABR) was used as an assay of binaural processing. BIC amplitude peaked for interaural electrode pairs at the same relative cochlear position and dropped with increasing cochlear separation in either direction. To test the hypothesis that BIC amplitude peaks when electrodes from the two sides activate maximally overlapping neural populations, we measured multiunit neural activity along the tonotopic gradient of the inferior colliculus (IC) with 16-channel recording probes and determined the spatial pattern of IC activation for each stimulating electrode. We found that the interaural electrode pairings that produced the best aligned IC activation patterns were also those that yielded maximum BIC amplitude. These results suggest that EABR measurements may provide a method for assigning frequency-channel mappings in bilateral implant recipients, such as pediatric patients, for which psychophysical measures of pitch ranking or binaural fusion are unavailable.

  3. Development and evaluation of the Nurotron 26-electrode cochlear implant system.

    PubMed

    Zeng, Fan-Gang; Rebscher, Stephen J; Fu, Qian-Jie; Chen, Hongbin; Sun, Xiaoan; Yin, Li; Ping, Lichuan; Feng, Haihong; Yang, Shiming; Gong, Shusheng; Yang, Beibei; Kang, Hou-Yong; Gao, Na; Chi, Fanglu

    2015-04-01

    Although the cochlear implant has been widely acknowledged as the most successful neural prosthesis, only a fraction of hearing-impaired people who can potentially benefit from a cochlear implant have actually received one due to its limited awareness, accessibility, and affordability. To help overcome these limitations, a 26-electrode cochlear implant has been developed to receive China's Food and Drug Administration (CFDA) approval in 2011 and Conformité Européenne (CE) Marking in 2012. The present article describes design philosophy, system specification, and technical verification of the Nurotron device, which includes advanced digital signal processing and 4 current sources with multiple amplitude resolutions that not only are compatible with perceptual capability but also allow interleaved or simultaneous stimulation. The article also presents 3-year longitudinal evaluation data from 60 human subjects who have received the Nurotron device. The objective measures show that electrode impedance decreased within the first month of device use, but was stable until a slight increase at the end of two years. The subjective loudness measures show that electric stimulation threshold was stable while the maximal comfort level increased over the 3 years. Mandarin sentence recognition increased from the pre-surgical 0%-correct score to a plateau of about 80% correct with 6-month use of the device. Both indirect and direct comparisons indicate indistinguishable performance differences between the Nurotron system and other commercially available devices. The present 26-electrode cochlear implant has already helped to lower the price of cochlear implantation in China and will likely contribute to increased cochlear implant access and success in the rest of the world. This article is part of a Special Issue entitled . Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.

  4. Evidence of across-channel processing for spectral-ripple discrimination in cochlear implant listeners a

    PubMed Central

    Ho Won, Jong; Jones, Gary L.; Drennan, Ward R.; Jameyson, Elyse M.; Rubinstein, Jay T.

    2011-01-01

    Spectral-ripple discrimination has been used widely for psychoacoustical studies in normal-hearing, hearing-impaired, and cochlear implant listeners. The present study investigated the perceptual mechanism for spectral-ripple discrimination in cochlear implant listeners. The main goal of this study was to determine whether cochlear implant listeners use a local intensity cue or global spectral shape for spectral-ripple discrimination. The effect of electrode separation on spectral-ripple discrimination was also evaluated. Results showed that it is highly unlikely that cochlear implant listeners depend on a local intensity cue for spectral-ripple discrimination. A phenomenological model of spectral-ripple discrimination, as an “ideal observer,” showed that a perceptual mechanism based on discrimination of a single intensity difference cannot account for performance of cochlear implant listeners. Spectral modulation depth and electrode separation were found to significantly affect spectral-ripple discrimination. The evidence supports the hypothesis that spectral-ripple discrimination involves integrating information from multiple channels. PMID:21973363

  5. Histaminergic H3-Heteroreceptors as a Potential Mediator of Betahistine-Induced Increase in Cochlear Blood Flow.

    PubMed

    Bertlich, Mattis; Ihler, Friedrich; Freytag, Saskia; Weiss, Bernhard G; Strupp, Michael; Canis, Martin

    2015-01-01

    Betahistine is a histamine-like drug that is considered beneficial in Ménière's disease by increasing cochlear blood flow. Acting as an agonist at the histamine H1-receptor and as an inverse agonist at the H3-receptor, these receptors as well as the adrenergic α2-receptor were investigated for betahistine effects on cochlear blood flow. A total of 54 Dunkin-Hartley guinea pigs were randomly assigned to one of nine groups treated with a selection of H1-, H3- or α2-selective agonists and antagonists together with betahistine. Cochlear blood flow and mean arterial pressure were recorded for 3 min before and 15 min after infusion. Blockage of the H3- or α2-receptors caused a suppression of betahistine-mediated typical changes in cochlear blood flow or blood pressure. Activation of H3-receptors caused a drop in cochlear blood flow and blood pressure. H1-receptors showed no involvement in betahistine-mediated changes of cochlear blood flow. Betahistine most likely affects cochlear blood flow through histaminergic H3-heteroreceptors. © 2015 S. Karger AG, Basel.

  6. Fingolimod (FTY-720) is Capable of Reversing Tumor Necrosis Factor Induced Decreases in Cochlear Blood Flow.

    PubMed

    Bertlich, Mattis; Ihler, Friedrich; Weiss, Bernhard G; Freytag, Saskia; Jakob, Mark; Strupp, Michael; Pellkofer, Hannah; Canis, Martin

    2017-09-01

    The potential of Fingolimod (FTY-720), a sphingosine-1-phosphate analogue, to revoke the changes in cochlear blood flow induced by tumor necrosis factor (TNF) was investigated. Impairment of cochlear blood flow has often been considered as the common final pathway of various inner ear pathologies. TNF, an ubiquitous cytokine, plays a major role in these pathologies, reducing cochlear blood flow via sphingosine-1-phosphate-signaling. Fifteen Dunkin-Hartley guinea pigs were randomly assigned to one of three groups (placebo/placebo, TNF/placebo, TNF/FTY-720). Cochlear microcirculation was quantified over 60 minutes by in vivo fluorescence microscopy before and after topical application of placebo or TNF (5 ng/ml) and after subsequent application of placebo or FTY-720 (200 μg/ml). Treatment with TNF led to a significant decrease of cochlear blood flow.Following this, application of placebo caused no significant changes while application of FTY-720 caused a significant rise in cochlear blood flow. FTY-720 is capable of reversing changes in cochlear blood flow induced by application of TNF. This makes FTY-720 a valid candidate for potential treatment of numerous inner ear pathologies.

  7. Effects of central nervous system residua on cochlear implant results in children deafened by meningitis.

    PubMed

    Francis, Howard W; Pulsifer, Margaret B; Chinnici, Jill; Nutt, Robert; Venick, Holly S; Yeagle, Jennifer D; Niparko, John K

    2004-05-01

    This study explored factors associated with speech recognition outcomes in postmeningitic deafness (PMD). The results of cochlear implantation may vary in children with PMD because of sequelae that extend beyond the auditory periphery. To determine which factors might be most determinative of outcome of cochlear implantation in children with PMD. Retrospective chart review. A referral center for pediatric cochlear implantation and rehabilitation. Thirty children with cochlear implants who were deafened by meningitis were matched with subjects who were deafened by other causes based on the age at diagnosis, age at cochlear implantation, age at which hearing aids were first used, and method of communication used at home or in the classroom. Speech perception performance within the first 2 years after cochlear implantation and its relationship with presurgical cognitive measures and medical history. There was no difference in the overall cognitive or postoperative speech perception performance between the children with PMD and those deafened by other causes. The presence of postmeningitic hydrocephalus, however, posed greater challenges to the rehabilitation process, as indicated by significantly smaller gains in speech perception and a predilection for behavioral problems. By comparison, cochlear scarring and incomplete electrode insertion had no impact on speech perception results. Although the results demonstrated no significant delay in cognitive or speech perception performance in the PMD group, central nervous system residua, when present, can impede the acquisition of speech perception with a cochlear implant. Central effects associated with PMD may thus impact language learning potential; cognitive and behavioral therapy should be considered in rehabilitative planning and in establishing expectations of outcome.

  8. Bringing Hearing to the Deaf--Cochlear Implants: a Technical and Personal Account

    NASA Astrophysics Data System (ADS)

    Shipsey, Ian

    2006-04-01

    Cochlear implants are the first device to successfully restore neural function. They have instigated a popular but controversial revolution in the treatment of deafness, and they serve as a model for research in neuroscience and biomedical engineering. In this talk the physiology of natural hearing will be reviewed from the perspective of a physicist, and the function of cochlear implants will be described in the context of historical treatments, electrical engineering, psychophysics, clinical evaluation of efficacy and personal experience. The social implications of cochlear implantation and the future outlook for auditory prostheses will also be discussed.

  9. Nijmegen Cochlear Implant Questionnaire (NCIQ): translation, cultural adaptation, and application in adults with cochlear implants.

    PubMed

    Santos, Nathália Porfírio Dos; Couto, Maria Inês Vieira; Martinho-Carvalho, Ana Claudia

    2017-12-11

    Cross-cultural adaptation and translation of the Nijmegen Cochlear Implant Questionnaire (NCIQ) into Brazilian Portuguese and analysis of quality of life (QoL) results in adults with cochlear implant (CI). The NCIQ instrument was translated into Brazilian Portuguese and culturally adapted. After that, a cross-sectional and clinical QoL evaluation was conducted with a group of 24 adults with CI. The questionnaire title in Brazilian Portuguese is 'Questionário Nijmegen de Implantes Cocleares' (NCIQ-P). The version of the NCIQ questionnaire translated into Brazilian Portuguese presented good internal consistency (0.78). The social and physical domains presented the highest scores, with the basic and advanced sound perception subdomains achieving the highest scores. No correlation between gender and time of device use was found for the questionnaire domains and subdomains. The cross-cultural adaptation and translation of the NCIQ into Brazilian Portuguese suggests that this instrument is reliable and useful for clinical and research purposes in Brazilian adults with CI.

  10. Psychometric validity of the Cochlear Implant Function Index (CIFI): a quality of life assessment tool for adult cochlear implant users.

    PubMed

    Coelho, Daniel H; Hammerschlag, Paul E; Bat-Chava, Yael; Kohan, Darius

    2009-06-01

    The Cochlear Implant Function Index (CIFI) is created to assess adult cochlear implant (CI) auditory effectiveness in real world situations. Our objective is to evaluate the CIFI as a reliable psychometric tool to assess 1) reliance on visual assistance, 2) telephone use, 3) communication at work, 4) 'hearing' in noise, 5) in groups, and 6) in large room settings. Based upon Guttman scaling properties, the CIFI elicits implanted respondent's functional level with auditory independence from Level 1 (still requiring signing) to level 4 (without any help beyond CI). A blinded, retrospective questionnaire is anonymously answered by cochlear implant recipients. CI centers of tertiary care medical centers, CI support group, and an interactive web page of a hearing and speech center in a large metropolitan region. 245 respondents from a varied adult CI population implanted for one month to 19 years prior to answering the questionnaire. An assessment tool of CI function. A coefficient of reproducibility (CR) for the Guttman scale format equal or greater than 0.90, indicating good scalability. CR in the CIFI was above 0.90. Effective scalability and mean scores from 2.5 to 3.5 for the six areas examined (1.00-4.00) were achieved. The psychometric properties of this user friendly survey demonstrate consistently good scalability. Based on these findings, the CIFI provides a validated tool that can be used for systematic comparisons between groups of patients or for follow-up outcomes in patients who use cochlear implants. Further study is indicated to correlate CIFI scores with sound and speech perception scores. Copyright 2009 John Wiley & Sons, Ltd.

  11. Cyborgization: Deaf Education for Young Children in the Cochlear Implantation Era

    ERIC Educational Resources Information Center

    Valente, Joseph Michael

    2011-01-01

    The author, who was raised oral deaf himself, recounts a visit to a school for young deaf children and discovers that young d/Deaf children and their rights are subverted by the cochlear implantation empire. The hypercapitalist, techno-manic times of cochlear implantation has wreaked havoc to the lives of not only young children with deafness but…

  12. Educational Interpreters: Meeting the Communication Needs of Children with Cochlear Implants

    ERIC Educational Resources Information Center

    Melton, Julie; Higbee, Renee

    2013-01-01

    Since the early 1990s, when the U.S. Food and Drug Administration approved cochlear implants for deaf and hard of hearing children, the number of children who have cochlear implants has increased in mainstream settings. Recent research suggests that these students, like their deaf and hard of hearing peers without implants who use sign language,…

  13. The scala vestibuli for cochlear implantation. An anatomic study.

    PubMed

    Gulya, A J; Steenerson, R L

    1996-02-01

    Traditionally, cochlear implantation has used the scala tympani (ST) for electrode insertion. When faced with ST ossification, the surgeon may elect to drill out the cochlea to accomplish partial electrode insertion. Theoretically, another option in this situation is to insert the electrode into the scala vestibuli (SV). To determine whether or not the dimensions of the SV are sufficient to accommodate an electrode array so as to assess the feasibility of SV cochlear implantation. The study of 20 normal human temporal bones, comparing the maximum diameter and surface area of the ST with those of the combined SV and scala media. The dimensions of the SV and scala media were comparable to those of the ST and appeared sufficient to accommodate a cochlear implant electrode array. It appears that the combination of SV and scala media is a viable alternative route for electrode insertion, at least on the basis of anatomic dimensions, in those cases in which the ST is obliterated.

  14. Long latency auditory evoked potentials in children with cochlear implants: systematic review.

    PubMed

    Silva, Liliane Aparecida Fagundes; Couto, Maria Inês Vieira; Matas, Carla Gentile; Carvalho, Ana Claudia Martinho de

    2013-11-25

    The aim of this study was to analyze the findings on Cortical Auditory Evoked Potentials in children with cochlear implant through a systematic literature review. After formulation of research question and search of studies in four data bases with the following descriptors: electrophysiology (eletrofisiologia), cochlear implantation (implante coclear), child (criança), neuronal plasticity (plasticidade neuronal) and audiology (audiologia), were selected articles (original and complete) published between 2002 and 2013 in Brazilian Portuguese or English. A total of 208 studies were found; however, only 13 contemplated the established criteria and were further analyzed; was made data extraction for analysis of methodology and content of the studies. The results described suggest rapid changes in P1 component of Cortical Auditory Evoked Potentials in children with cochlear implants. Although there are few studies on the theme, cochlear implant has been shown to produce effective changes in central auditory path ways especially in children implanted before 3 years and 6 months of age.

  15. A phone-assistive device based on Bluetooth technology for cochlear implant users.

    PubMed

    Qian, Haifeng; Loizou, Philipos C; Dorman, Michael F

    2003-09-01

    Hearing-impaired people, and particularly hearing-aid and cochlear-implant users, often have difficulty communicating over the telephone. The intelligibility of telephone speech is considerably lower than the intelligibility of face-to-face speech. This is partly because of lack of visual cues, limited telephone bandwidth, and background noise. In addition, cellphones may cause interference with the hearing aid or cochlear implant. To address these problems that hearing-impaired people experience with telephones, this paper proposes a wireless phone adapter that can be used to route the audio signal directly to the hearing aid or cochlear implant processor. This adapter is based on Bluetooth technology. The favorable features of this new wireless technology make the adapter superior to traditional assistive listening devices. A hardware prototype was built and software programs were written to implement the headset profile in the Bluetooth specification. Three cochlear implant users were tested with the proposed phone-adapter and reported good speech quality.

  16. Intracochlear pressure measurements in scala media inform models of cochlear mechanics

    NASA Astrophysics Data System (ADS)

    Kale, Sushrut; Olson, Elizabeth S.

    2015-12-01

    In the classic view of cochlear mechanics, the cochlea is comprised of two identical fluid chambers separated by the cochlear partition (CP). In this view the traveling wave pressures in the two chambers mirror each other; they are equal in magnitude and opposite in phase. A fast pressure mode adds approximately uniformly. More recent models of cochlear mechanics take into account the structural complexity of the CP and the resulting additional mechanical modes would lead to distinct (non-symmetric) patterns of pressure and motion on the two sides of the CP. However, there was little to no physiological data that explored these predictions. To this aim, we measured intracochlear fluid pressure in scala media (SM), including measurements close to the sensory tissue, using miniaturized pressure sensors (˜ 80 μm outer diameter). Measurements were made in-vivo from the basal cochlear turn in gerbils. SM pressure was measured at two longitudinal locations in different preparations. In a subset of the experiments SM and ST (scala tympani) pressures were measured at the same longitudinal location. Traveling wave pressures were observed in both SM and ST, and showed the relative phase predicted by the classical theory. In addition, SM pressure showed spatial variations that had not been observed in ST, which points to a relatively complex CP motion on the SM side. These data both underscore the first-order validity of the classic cochlear traveling wave model, and open a new view to CP mechanics.

  17. Morphoscopic analysis of experimentally produced bony wounds from low-velocity ballistic impact.

    PubMed

    Kieser, Jules A; Tahere, Joy; Agnew, Caitlin; Kieser, David C; Duncan, Warwick; Swain, Michael V; Reeves, Matthew T

    2011-12-01

    Understanding how bone behaves when subjected to ballistic impact is of critical importance for forensic questions, such as the reconstruction of shooting events. Yet the literature addressing microscopic anatomical features of gunshot wounds to different types of bone is sparse. Moreover, a biomechanical framework for describing how the complex architecture of bone affects its failure during such impact is lacking. The aim of this study was to examine the morphological features associated with experimental gunshot wounds in slaughtered pig ribs. We shot the 4th rib of 12 adult pigs with .22 mm subsonic bullets at close range (5 cm) and examined resultant wounds under the light microscope, scanning electron microscope SEM and micro tomograph μCT. In all cases there was a narrow shot channel followed by spall region, with evidence of plastic deformation with burnishing of the surface bone in the former, and brittle fracture around and through individual Haversian systems in the latter. In all but one case, the entrance wounds were characterized by superficially fractured cortical bone in the form of a well-defined collar, while the exit wounds showed delamination of the periosteum. Inorganic residue was evident in all cases, with electron energy dispersive spectroscopy EDS confirming the presence of carbon, phosphate, lead and calcium. This material appeared to be especially concentrated within the fractured bony collar at the entrance. We conclude that gunshot wounds in flat bones may be morphologically divided into a thin burnished zone at the entry site, and a fracture zone at the exit.

  18. Timing Discrepancies of Early Intervention Hearing Services in Urban and Rural Cochlear Implant Recipients

    PubMed Central

    Bush, Matthew L.; Burton, Mary; Loan, Ashley; Shinn, Jennifer B.

    2013-01-01

    Objective The purpose of this study was to examine the timing of early intervention diagnostic and therapeutic services in cochlear implant recipients from rural and urban areas. Study design Retrospective case series review Setting Tertiary referral center Patients Cochlear implant recipients from a single comprehensive hearing institute born with severe congenital sensorineural hearing loss were examined. Timing of diagnostic and therapeutic services was examined. Intervention(s) Diagnosis, amplification, and eventual cochlear implantation for all patients in the study Main outcome measure(s) Time points of definitive diagnosis, amplification, and cochlear implantation for children from urban and rural regions were examined. Correlation analysis of distance to testing center and timing of services was also assessed. Results 40 children born with congenital hearing loss were included in the study and were diagnosed at a median age of 13 weeks after birth. Children from rural regions obtained amplification at a median age of 47.7 weeks after birth, while urban children were amplified at 26 weeks after birth. Cochlear implantation was performed at a median age of 182 weeks after birth in those from rural areas and at 104 weeks after birth in urban-dwelling patients. A linear relationship was identified between distance to the implant center and timing of hearing aid amplification (r=0.5, p=0.033) and cochlear implantation (r=0.5, p=0.016). Conclusions Children residing outside of metro areas may be at higher risk of delayed rehabilitative services and cochlear implantation than those residing in urban areas that may be closer in proximity to tertiary care centers. PMID:24136305

  19. Interaction of tinnitus suppression and hearing ability after cochlear implantation.

    PubMed

    Wang, Qian; Li, Jia-Nan; Lei, Guan-Xiong; Chen, Dai-Shi; Wang, Wei-Ze; Chen, Ai-Ting; Mong, Meng-Di; Li, Sun; Jiao, Qing-Shan; Yang, Shi-Ming

    2017-10-01

    To study the postoperative impact of cochlear implants (CIs) on tinnitus, as well as the impact of tinnitus on speech recognition with CI switched on. Fifty-two postlingual deafened CI recipients (21 males and 31 females) were assessed using an established Tinnitus Characteristics Questionnaire and Tinnitus Handicap Inventory (THI) before and after cochlear implantation. The tinnitus loudness was investigated when CI was switched on and off in CI recipients with persistent tinnitus. The relation between tinnitus loudness and recipients' satisfaction of cochlear implantation was analyzed by the visual analogue scale (VAS) score. With CI 'OFF', 42 CI recipients experienced tinnitus postimplant ipsilaterally and 44 contralaterally. Tinnitus was totally suppressed ipsilateral to the CI with CI 'ON' in 42.9%, partially suppressed in 42.9%, unchanged in 11.9% and aggravated in 2.4%. Tinnitus was totally suppressed contralaterally with CI 'ON' in 31.8% of CI recipients, partially suppressed in 47.7%, unchanged in 20.5%. Pearson correlation analysis showed that tinnitus loudness and the results of cochlear implant patients satisfaction was negatively correlated (r = .674, p < .001). The study suggests six-month CI activation can be effective for suppressing tinnitus. The tinnitus loudness may affect patients' satisfaction with the use of CI.

  20. Cochlear implants and spoken language processing abilities: review and assessment of the literature.

    PubMed

    Peterson, Nathaniel R; Pisoni, David B; Miyamoto, Richard T

    2010-01-01

    Cochlear implants (CIs) process sounds electronically and then transmit electric stimulation to the cochlea of individuals with sensorineural deafness, restoring some sensation of auditory perception. Many congenitally deaf CI recipients achieve a high degree of accuracy in speech perception and develop near-normal language skills. Post-lingually deafened implant recipients often regain the ability to understand and use spoken language with or without the aid of visual input (i.e. lip reading). However, there is wide variation in individual outcomes following cochlear implantation, and some CI recipients never develop useable speech and oral language skills. The causes of this enormous variation in outcomes are only partly understood at the present time. The variables most strongly associated with language outcomes are age at implantation and mode of communication in rehabilitation. Thus, some of the more important factors determining success of cochlear implantation are broadly related to neural plasticity that appears to be transiently present in deaf individuals. In this article we review the expected outcomes of cochlear implantation, potential predictors of those outcomes, the basic science regarding critical and sensitive periods, and several new research directions in the field of cochlear implantation.

  1. Clinical outcomes of scala vestibuli cochlear implantation in children with partial labyrinthine ossification.

    PubMed

    Lin, Yung-Song

    2009-03-01

    Cochlear implantation via the scala vestibuli is a viable approach in those with ossification in the scala tympani. With extended cochlear implant experience, there is no significant difference in the mapping parameters and auditory performance between those implanted via scala vestibuli and via scala tympani. To assess the clinical outcomes of cochlear implantation via scala vestibuli. In a cohort follow-up study, 11 prelingually deafened children who received cochlear implantation between age 3 and 10 years through the scala vestibuli served as participants. The mapping parameters (i.e. comfortable level (C), threshold level (T), dynamic range) and auditory performance of each participant were evaluated following initial cochlear implant stimulation, then at 3 month intervals for 2 years, then semi-annually. The follow-up period lasted for 9 years 9 months on average, with a minimum of 8 years 3 months. The clinical results of the mapping parameters and auditory performance of children implanted via the scala vestibuli were comparative to those who were implanted via the scala tympani. No balance problem was reported by any of these patients. One child exhibited residual low frequency hearing after implantation.

  2. Auditory Speech Perception Tests in Relation to the Coding Strategy in Cochlear Implant.

    PubMed

    Bazon, Aline Cristine; Mantello, Erika Barioni; Gonçales, Alina Sanches; Isaac, Myriam de Lima; Hyppolito, Miguel Angelo; Reis, Ana Cláudia Mirândola Barbosa

    2016-07-01

    The objective of the evaluation of auditory perception of cochlear implant users is to determine how the acoustic signal is processed, leading to the recognition and understanding of sound. To investigate the differences in the process of auditory speech perception in individuals with postlingual hearing loss wearing a cochlear implant, using two different speech coding strategies, and to analyze speech perception and handicap perception in relation to the strategy used. This study is prospective cross-sectional cohort study of a descriptive character. We selected ten cochlear implant users that were characterized by hearing threshold by the application of speech perception tests and of the Hearing Handicap Inventory for Adults. There was no significant difference when comparing the variables subject age, age at acquisition of hearing loss, etiology, time of hearing deprivation, time of cochlear implant use and mean hearing threshold with the cochlear implant with the shift in speech coding strategy. There was no relationship between lack of handicap perception and improvement in speech perception in both speech coding strategies used. There was no significant difference between the strategies evaluated and no relation was observed between them and the variables studied.

  3. Pediatric Cochlear Implants: An Overview of the Alternatives in Education and Rehabilitation.

    ERIC Educational Resources Information Center

    Barnes, Judith M., Ed.; And Others

    This collection of 10 papers is intended as a resource book integrating information on pediatric cochlear implants for educators, parents, implant teams, and rehabilitation specialists. The papers focus on the importance of providing an oral educational environment to maximize cochlear implant success. An introduction notes controversies in the…

  4. The contribution of short-term memory capacity to reading ability in adolescents with cochlear implants.

    PubMed

    Edwards, Lindsey; Aitkenhead, Lynne; Langdon, Dawn

    2016-11-01

    This study aimed to establish the relationship between short-term memory capacity and reading skills in adolescents with cochlear implants. A between-groups design compared a group of young people with cochlear implants with a group of hearing peers on measures of reading, and auditory and visual short-term memory capacity. The groups were matched for non-verbal IQ and age. The adolescents with cochlear implants were recruited from the Cochlear Implant Programme at a specialist children's hospital. The hearing participants were recruited from the same schools as those attended by the implanted adolescents. Participants were 18 cochlear implant users and 14 hearing controls, aged between 12 and 18 years. All used English as their main language and had no significant learning disability or neuro-developmental disorder. Short-term memory capacity was assessed in the auditory modality using Forward and Reverse Digit Span from the WISC IV UK, and visually using Forward and Reverse Memory from the Leiter-R. Individual word reading, reading comprehension and pseudoword decoding were assessed using the WIAT II UK. A series of ANOVAs revealed that the adolescents with cochlear implants had significantly poorer auditory short-term memory capacity and reading skills (on all measures) compared with their hearing peers. However, when Forward Digit Span was entered into the analyses as a covariate, none of the differences remained statistically significant. Deficits in immediate auditory memory persist into adolescence in deaf children with cochlear implants. Short-term auditory memory capacity is an important neurocognitive process in the development of reading skills after cochlear implantation in childhood that remains evident in later adolescence. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. Developmental Effects of Family Environment on Outcomes in Pediatric Cochlear Implant Recipients

    PubMed Central

    Holt, Rachael Frush; Beer, Jessica; Kronenberger, William G.; Pisoni, David B.

    2012-01-01

    Objective To examine and compare the family environment of preschool- and school-age children with cochlear implants and assess its influence on children’s executive function and spoken language skills. Study Design Retrospective between-subjects design. Setting Outpatient research laboratory. Patients Prelingually deaf children with cochlear implants and no additional disabilities, and their families. Intervention(s) Cochlear implantation and speech-language therapy. Main Outcome Measures Parents completed the Family Environment Scale and the Behavior Rating Inventory of Executive Function (or the preschool version). Children were tested using the Peabody Picture Vocabulary Test-4 and either the Preschool Language Scales-4 or the Clinical Evaluation of Language Fundamentals–4. Results The family environments of children with cochlear implants differed from normative data obtained from hearing children, but average scores were within one standard deviation of norms on all subscales. Families of school-age children reported higher levels of control than those of preschool-age children. Preschool-age children had fewer problems with emotional control when families reported higher levels of support and lower levels of conflict. School-age children had fewer problems with inhibition but more problems with shifting of attention when families reported lower levels of conflict. School-age children’s receptive vocabularies were enhanced by families with lower levels of control and higher levels of organization. Conclusions Family environment and its relation to language skills and executive function development differed across the age groups in this sample of children with cochlear implants. Because family dynamics is one developmental/environmental factor that can be altered with therapy and education, the present results have important clinical implications for family-based interventions for deaf children with cochlear implants. PMID:23151776

  6. The relationship between the lizard eye and associated bony features: a cautionary note for interpreting fossil activity patterns.

    PubMed

    Hall, Margaret I

    2009-06-01

    Activity pattern, the time of day when an animal is active, is associated with ecology. There are two major activity patterns: diurnal (awake during the day in a photopic environment) and nocturnal (awake at night in a scotopic environment). Lizards exhibit characteristic eye shapes associated with activity pattern, with scotopic-adapted lizard eyes optimized for visual sensitivity with large corneal diameters relative to their eye axial lengths, and photopic-adapted lizards optimized for visual acuity, with larger axial lengths of the eye relative to their corneal diameters. This study: (1) quantifies the relationship between the lizard eye and its associated bony anatomy (the orbit, sclerotic ring, and associated skull widths); (2) investigates how activity pattern is reflected in that bony anatomy; and (3) determines if it is possible to reliably interpret activity pattern for a lizard that does not have the soft tissue available for study, specifically, for a fossil. Knowledge of extinct lizards' activity patterns would be useful in making paleoecological interpretations. Here, 96 scotopic- and photopic-adapted lizard species are analyzed in a phylogenetic context. Although there is a close relationship between the lepidosaur eye and associated bony anatomy, based on these data activity pattern cannot be reliably interpreted for bony-only specimens, such as a fossil, possibly because of the limited ossification of the lepidosaur skull. Caution should be exercised when utilizing lizard bony anatomy to interpret light-level adaptation, either for a fossil lizard or as part of an extant phylogenetic bracket to interpret other extinct animals with sclerotic rings, such as dinosaurs. (c) 2009 Wiley-Liss, Inc.

  7. The cost and analysis of nonuse of cochlear implants.

    PubMed

    Raine, Christopher H; Summerfield, Quentin; Strachan, David R; Martin, Jane M; Totten, Catherine

    2008-02-01

    Analysis of the cost implications and reasons for nonuse of cochlear implants in an established cochlear implant unit. Clinical data were analyzed retrospectively to construct a table of cochlear implant use over time to identify nonuse and to suggest the reasons for this. Yorkshire Cochlear Implant Service is a tertiary referral center. Three hundred forty consecutively implanted patients from 1990 to 2005. Life table analysis showed that most children used their implant (p = 0.7 during 11 yr). However, 11 of 155 children and 2 of 185 adults became nonusers during the period of study. The 11 children stopped because of age at implant, educational placement, and family support. Two adults stopped because of psychological issues and inability to adapt to the signal. Surgical and implant costs have initial impact, with subsequent years' costs reflecting programming issues and maintenance. When considering nonuse, there are 2 effects: first, no more costs are incurred, and second, no more years of use are accumulated. Thus, nonuse reduces both costs and years. Costs of gaining a year of use as a function of time showed that there was little financial impact from the 11 children nonusers. As a ratio of "no nonuse" and observed "nonuse" in children, the ratio is 1.07 by 13 years of implantation (7%). The adult group was too few to analyze. The nonuse added 7% to the average cost. Retrospective audit identifies that patient selection by a multidisciplinary team is crucial to reducing nonuse.

  8. [DPOAE in tinnitus patients with cochlear hearing loss considering hyperacusis and misophonia].

    PubMed

    Sztuka, Aleksandra; Pośpiech, Lucyna; Gawron, Wojciech; Dudek, Krzysztof

    2006-01-01

    The most probable place generating tinnitus in auditory pathway are outer hair cells (OHC) inside cochlea. To asses their activity otoacoustic emission is used. The goal of the investigation was estimation the features of otoemission DPOAE in groups with tinnitus patients with cochlear hearing loss, estimation of diagnostic value of DPOAE parameters for analysis of function of the cochlea in investigated patients emphasizing DPOAE parameters most useful in localizing tinnitus generators and estimation of hypothetic influence of hyperacusis and misophony on parameters of DPOAE in tinnitus patients with cochlear hearing loss. The material of the study were 42 tinnitus patients with cochlear hearing loss. In the control group there were 21 patients without tinnitus with the same type of hearing loss. Then tinnitus patients were divided into three subgroups--with hyperacusis, misophony and without both of them, based on audiologic findings. after taking view on tinnitus and physical examination in all the patients pure tone and impedance audiometry, supratreshold tests, ABR and audiometric average and discomfort level were evaluated. Then otoemission DPOAE was measured in three procedures. First the amplitudes of two points per octave were assessed, in second--"fine structure" method-- 16-20 points per octave (f2/f1 = 1.2, L1 = L2 = 70 dB). Third procedure included recording of growth rate function in three series for input tones of value f2 = 2002, 4004, 6006 Hz (f2/f1= 1.22) and levels L1=L2, growing by degrees of 5dB in each series. DPOAE amplitudes in recording of 2 points per octave and fine structure method are very valuable parameters for estimation of cochlear function in tinnitus patients with cochlear hearing loss. Decreasing of DPOAE amplitudes in patients with cochlear hearing loss and tinnitus suggests significant role of OHC pathology, unbalanced by IHC injury in generation of tinnitus in patients with hearing loss of cochlear localization. DPOAE fine

  9. Comparison of intelligence quotients of first- and second-generation deaf children with cochlear implants.

    PubMed

    Amraei, K; Amirsalari, S; Ajalloueyan, M

    2017-01-01

    Hearing impairment is a common type of sensory loss in children. Studies indicate that children with hearing impairment are deficient in social, cognitive and communication skills. This study compared the intelligence quotients of first- and second-generation deaf children with cochlear implants. This research is causal-comparative. All 15 deaf children investigated had deaf parents and were selected from Baqiyatallah Cochlear Implant Center. The 15 children with cochlear implants were paired with similar children with hearing parents using purposive sampling. The findings show that the Hotelling trace of multivariate analysis of variance (F = 6.78, p < 0.01, η P 2  = 0.73) was significant. The tests of between-subjects effects for second-generation children was significantly higher than for first-generation children for all intelligence scales except knowledge. It can be assumed that second-generation children joined their family in the use of sign language as the primary experience before a cochlear implant. The use of sign language before cochlear implants is recommended. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  10. The Tree of Life and a New Classification of Bony Fishes

    PubMed Central

    Betancur-R., Ricardo; Broughton, Richard E.; Wiley, Edward O.; Carpenter, Kent; López, J. Andrés; Li, Chenhong; Holcroft, Nancy I.; Arcila, Dahiana; Sanciangco, Millicent; Cureton II, James C; Zhang, Feifei; Buser, Thaddaeus; Campbell, Matthew A.; Ballesteros, Jesus A; Roa-Varon, Adela; Willis, Stuart; Borden, W. Calvin; Rowley, Thaine; Reneau, Paulette C.; Hough, Daniel J.; Lu, Guoqing; Grande, Terry; Arratia, Gloria; Ortí, Guillermo

    2013-01-01

    The tree of life of fishes is in a state of flux because we still lack a comprehensive phylogeny that includes all major groups. The situation is most critical for a large clade of spiny-finned fishes, traditionally referred to as percomorphs, whose uncertain relationships have plagued ichthyologists for over a century. Most of what we know about the higher-level relationships among fish lineages has been based on morphology, but rapid influx of molecular studies is changing many established systematic concepts. We report a comprehensive molecular phylogeny for bony fishes that includes representatives of all major lineages. DNA sequence data for 21 molecular markers (one mitochondrial and 20 nuclear genes) were collected for 1410 bony fish taxa, plus four tetrapod species and two chondrichthyan outgroups (total 1416 terminals). Bony fish diversity is represented by 1093 genera, 369 families, and all traditionally recognized orders. The maximum likelihood tree provides unprecedented resolution and high bootstrap support for most backbone nodes, defining for the first time a global phylogeny of fishes. The general structure of the tree is in agreement with expectations from previous morphological and molecular studies, but significant new clades arise. Most interestingly, the high degree of uncertainty among percomorphs is now resolved into nine well-supported supraordinal groups. The order Perciformes, considered by many a polyphyletic taxonomic waste basket, is defined for the first time as a monophyletic group in the global phylogeny. A new classification that reflects our phylogenetic hypothesis is proposed to facilitate communication about the newly found structure of the tree of life of fishes. Finally, the molecular phylogeny is calibrated using 60 fossil constraints to produce a comprehensive time tree. The new time-calibrated phylogeny will provide the basis for and stimulate new comparative studies to better understand the evolution of the amazing

  11. The Role of MRI in Diagnosing Neurovascular Compression of the Cochlear Nerve Resulting in Typewriter Tinnitus.

    PubMed

    Bae, Y J; Jeon, Y J; Choi, B S; Koo, J-W; Song, J-J

    2017-06-01

    Typewriter tinnitus, a symptom characterized by paroxysmal attacks of staccato sounds, has been thought to be caused by neurovascular compression of the cochlear nerve, but the correlation between radiologic evidence of neurovascular compression of the cochlear nerve and symptom presentation has not been thoroughly investigated. The purpose of this study was to examine whether radiologic evidence of neurovascular compression of the cochlear nerve is pathognomonic in typewriter tinnitus. Fifteen carbamazepine-responding patients with typewriter tinnitus and 8 control subjects were evaluated with a 3D T2-weighted volume isotropic turbo spin-echo acquisition sequence. Groups 1 (16 symptomatic sides), 2 (14 asymptomatic sides), and 3 (16 control sides) were compared with regard to the anatomic relation between the vascular loop and the internal auditory canal and the presence of neurovascular compression of the cochlear nerve with/without angulation/indentation. The anatomic location of the vascular loop was not significantly different among the 3 groups (all, P > .05). Meanwhile, neurovascular compression of the cochlear nerve on MR imaging was significantly higher in group 1 than in group 3 ( P = .032). However, considerable false-positive (no symptoms with neurovascular compression of the cochlear nerve on MR imaging) and false-negative (typewriter tinnitus without demonstrable neurovascular compression of the cochlear nerve) findings were also observed. Neurovascular compression of the cochlear nerve was more frequently detected on the symptomatic side of patients with typewriter tinnitus compared with the asymptomatic side of these patients or on both sides of control subjects on MR imaging. However, considering false-positive and false-negative findings, meticulous history-taking and the response to the initial carbamazepine trial should be regarded as more reliable diagnostic clues than radiologic evidence of neurovascular compression of the cochlear nerve.

  12. Phase contrast tomography of the mouse cochlea at microfocus x-ray sources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bartels, Matthias; Krenkel, Martin; Hernandez, Victor H.

    2013-08-19

    We present phase contrast x-ray tomography of functional soft tissue within the bony cochlear capsule of mice, carried out at laboratory microfocus sources with well-matched source, detector, geometry, and reconstruction algorithms at spatial resolutions down to 2 μm. Contrast, data quality and resolution enable the visualization of thin membranes and nerve fibers as well as automated segmentation of surrounding bone. By complementing synchrotron radiation imaging techniques, a broad range of biomedical applications becomes possible as demonstrated for optogenetic cochlear implant research.

  13. Cochlear implant challenges encountered in tuberculous otitis media.

    PubMed

    Chen, Cheng-Fang; Liu, Zhao-Hui; Xie, Jing; Ma, Xiao-Bo; Li, Yi; Gong, Shu-Sheng

    2012-05-01

    Tuberculous otitis media (TOM) is rare in ENT department, and is frequently misdiagnosed as otitis media. Thus early systemic treatment is very important for TOM. We reported a case report with TOM to highlight development of the disease and difficulties in clinical treatment in late stage of TOM. Implantation of ossified and eroded cochlea poses many unique challenges to both the surgeon and programming team. With thorough preparation and complete knowledge about characters of specific issues, implantation would be performed successfully, and patients with ossified cochlear could benefit from cochlear implantation. Copyright © 2012 Hainan Medical College. Published by Elsevier B.V. All rights reserved.

  14. Supporting skill acquisition in cochlear implant surgery through virtual reality simulation.

    PubMed

    Copson, Bridget; Wijewickrema, Sudanthi; Zhou, Yun; Piromchai, Patorn; Briggs, Robert; Bailey, James; Kennedy, Gregor; O'Leary, Stephen

    2017-03-01

    To evaluate the effectiveness of a virtual reality (VR) temporal bone simulator in training cochlear implant surgery. We compared the performance of 12 otolaryngology registrars conducting simulated cochlear implant surgery before (pre-test) and after (post-tests) receiving training on a VR temporal bone surgery simulator with automated performance feedback. The post-test tasks were two temporal bones, one that was a mirror image of the temporal bone used as a pre-test and the other, a novel temporal bone. Participant performances were assessed by an otologist with a validated cochlear implant competency assessment tool. Structural damage was derived from an automatically generated simulator metric and compared between time points. Wilcoxon signed-rank test showed that there was a significant improvement with a large effect size in the total performance scores between the pre-test (PT) and both the first and second post-tests (PT1, PT2) (PT-PT1: P = 0.007, r = 0.78, PT-PT2: P = 0.005, r = 0.82). The results of the study indicate that VR simulation with automated guidance can effectively be used to train surgeons in training complex temporal bone surgeries such as cochlear implantation.

  15. Mandarin Chinese Tone Identification in Cochlear Implants: Predictions from Acoustic Models

    PubMed Central

    Morton, Kenneth D.; Torrione, Peter A.; Throckmorton, Chandra S.; Collins, Leslie M.

    2015-01-01

    It has been established that current cochlear implants do not supply adequate spectral information for perception of tonal languages. Comprehension of a tonal language, such as Mandarin Chinese, requires recognition of lexical tones. New strategies of cochlear stimulation such as variable stimulation rate and current steering may provide the means of delivering more spectral information and thus may provide the auditory fine structure required for tone recognition. Several cochlear implant signal processing strategies are examined in this study, the continuous interleaved sampling (CIS) algorithm, the frequency amplitude modulation encoding (FAME) algorithm, and the multiple carrier frequency algorithm (MCFA). These strategies provide different types and amounts of spectral information. Pattern recognition techniques can be applied to data from Mandarin Chinese tone recognition tasks using acoustic models as a means of testing the abilities of these algorithms to transmit the changes in fundamental frequency indicative of the four lexical tones. The ability of processed Mandarin Chinese tones to be correctly classified may predict trends in the effectiveness of different signal processing algorithms in cochlear implants. The proposed techniques can predict trends in performance of the signal processing techniques in quiet conditions but fail to do so in noise. PMID:18706497

  16. Spatial channel interactions in cochlear implants

    NASA Astrophysics Data System (ADS)

    Tang, Qing; Benítez, Raul; Zeng, Fan-Gang

    2011-08-01

    The modern multi-channel cochlear implant is widely considered to be the most successful neural prosthesis owing to its ability to restore partial hearing to post-lingually deafened adults and to allow essentially normal language development in pre-lingually deafened children. However, the implant performance varies greatly in individuals and is still limited in background noise, tonal language understanding, and music perception. One main cause for the individual variability and the limited performance in cochlear implants is spatial channel interaction from the stimulating electrodes to the auditory nerve and brain. Here we systematically examined spatial channel interactions at the physical, physiological, and perceptual levels in the same five modern cochlear implant subjects. The physical interaction was examined using an electric field imaging technique, which measured the voltage distribution as a function of the electrode position in the cochlea in response to the stimulation of a single electrode. The physiological interaction was examined by recording electrically evoked compound action potentials as a function of the electrode position in response to the stimulation of the same single electrode position. The perceptual interactions were characterized by changes in detection threshold as well as loudness summation in response to in-phase or out-of-phase dual-electrode stimulation. To minimize potentially confounding effects of temporal factors on spatial channel interactions, stimulus rates were limited to 100 Hz or less in all measurements. Several quantitative channel interaction indexes were developed to define and compare the width, slope and symmetry of the spatial excitation patterns derived from these physical, physiological and perceptual measures. The electric field imaging data revealed a broad but uniformly asymmetrical intracochlear electric field pattern, with the apical side producing a wider half-width and shallower slope than the basal

  17. [Cochlear implant in children: rational, indications and cost/efficacy].

    PubMed

    Martini, A; Bovo, R; Trevisi, P; Forli, F; Berrettini, S

    2013-06-01

    A cochlear implant (CI) is a partially implanted electronic device that can help to provide a sense of sound and support speech to severely to profoundly hearing impaired patients. It is constituted by an external portion, that usually sits behind the ear and an internal portion surgically placed under the skin. The external components include a microphone connected to a speech processor that selects and arranges sounds pucked up by the microphone. This is connected to a transmitter coil, worn on the side of the head, which transmits data to an internal receiver coil placed under the skin. The received data are delivered to an array of electrodes that are surgically implanted within the cochlea. The primary neural targets of the electrodes are the spiral ganglion cells which innervate fibers of the auditory nerve. When the electrodes are activated by the signal, they send a current along the auditory nerve and auditory pathways to the auditory cortex. Children and adults who are profoundly or severely hearing impaired can be fitted with cochlear implants. According to the Food and Drug Administration, approximately 188,000 people worldwide have received implants. In Italy it is extimated that there are about 6-7000 implanted patients, with an average of 700 CI surgeries per year. Cochlear implantation, followed by intensive postimplantation speech therapy, can help young children to acquire speech, language, and social skills. Early implantation provides exposure to sounds that can be helpful during the critical period when children learn speech and language skills. In 2000, the Food and Drug Administration lowered the age of eligibility to 12 months for one type of CI. With regard to the results after cochlear implantation in relation to early implantation, better linguistic results are reported in children implanted before 12 months of life, even if no sufficient data exist regarding the relation between this advantage and the duration of implant use and how long

  18. Deep brain stimulation with a pre-existing cochlear implant: Surgical technique and outcome.

    PubMed

    Eddelman, Daniel; Wewel, Joshua; Wiet, R Mark; Metman, Leo V; Sani, Sepehr

    2017-01-01

    Patients with previously implanted cranial devices pose a special challenge in deep brain stimulation (DBS) surgery. We report the implantation of bilateral DBS leads in a patient with a cochlear implant. Technical nuances and long-term interdevice functionality are presented. A 70-year-old patient with advancing Parkinson's disease and a previously placed cochlear implant for sensorineural hearing loss was referred for placement of bilateral DBS in the subthalamic nucleus (STN). Prior to DBS, the patient underwent surgical removal of the subgaleal cochlear magnet, followed by stereotactic MRI, frame placement, stereotactic computed tomography (CT), and merging of imaging studies. This technique allowed for successful computational merging, MRI-guided targeting, and lead implantation with acceptable accuracy. Formal testing and programming of both the devices were successful without electrical interference. Successful DBS implantation with high resolution MRI-guided targeting is technically feasible in patients with previously implanted cochlear implants by following proper precautions.

  19. Changing patterns of peanut agglutinin labelling in the dorsal cochlear nucleus correspond to axonal ingrowth.

    PubMed Central

    Riggs, G H; Schweitzer, L

    1994-01-01

    Various studies have suggested that glycoconjugates may influence connectivity and lamination in the developing central nervous system and may function as barriers to neuritic extension. It has been proposed that the peanut agglutinin lectin labels a glycoconjugate subserving a barrier function. We chose to investigate the distribution of this peanut-agglutinin-labelled glycoconjugate in the dorsal cochlear nucleus of the developing hamster since the development of the dorsal cochlear nucleus is well characterised and its axons obey laminar boundaries. The distribution of peanut agglutinin label throughout the cochlear nucleus delineated zones that cochlear axons fail to invade. In the dorsal cochlear nucleus, laminar differences were reduced on postnatal d 13 and virtually disappearing by postnatal d 23. Label in the molecular layer dissipated as axons and dendrites grew into this layer. These patterns of peanut agglutinin binding correspond to axonal ingrowth and are consistent with a barrier function for glycoconjugates in the molecular layer. Images Fig. 1 Fig. 2 Fig. 4 PMID:7961144

  20. Cochlear implantation in adults: a systematic review and meta-analysis.

    PubMed

    Gaylor, James M; Raman, Gowri; Chung, Mei; Lee, Jounghee; Rao, Madhumathi; Lau, Joseph; Poe, Dennis S

    2013-03-01

    Sensorineural hearing loss is the third leading cause of years lived with disability worldwide. Cochlear implants may provide a viable alternative to hearing aids for this type of hearing loss. The Coverage and Analysis Group at the Centers for Medicare & Medicaid Services was interested in an evaluation of recently published literature on this topic. In addition, this meta-analysis is to our knowledge the first to evaluate quality-of-life (QOL) outcomes in adults with cochlear implants. To evaluate the communication-related outcomes and health-related QOL outcomes after unilateral or bilateral cochlear implantation in adults with sensorineural hearing loss. MEDLINE, Cochrane Central Register of Controlled Trials, Scopus, and previous reports from January 1, 2004, through May 31, 2012. Published studies of adult patients undergoing unilateral or bilateral procedures with multichannel cochlear implants and assessments using open-set sentence tests, multisyllable word tests, or QOL measures. Five researchers extracted information on population characteristics, outcomes of interest, and study design and assessed the studies for risk of bias. Discrepancies were resolved by consensus. A total of 42 studies met the inclusion criteria. Most unilateral implant studies showed a statistically significant improvement in mean speech scores as measured by open-set sentence or multisyllable word tests; meta-analysis revealed a significant improvement in QOL after unilateral implantation. Results from studies assessing bilateral implantation showed improvement in communication-related outcomes compared with unilateral implantation and additional improvements in sound localization compared with unilateral device use or implantation only. Based on a few studies, the QOL outcomes varied across tests after bilateral implantation. Unilateral cochlear implants provide improved hearing and significantly improve QOL, and improvements in sound localization are noted for bilateral

  1. Hepatocyte nuclear factor-4 alpha in noise-induced cochlear neuropathy.

    PubMed

    Groth, Jane Bjerg; Kao, Shyan-Yuan; Briët, Martijn C; Stankovic, Konstantina M

    2016-12-01

    Noise-induced hearing loss (NIHL) is a problem of profound clinical significance and growing magnitude. Alarmingly, even moderate noise levels, previously assumed to cause only temporary shifts in auditory thresholds ("temporary" NIHL), are now known to cause cochlear synaptopathy and subsequent neuropathy. To uncover molecular mechanisms of this neuropathy, a network analysis of genes reported to have significantly altered expression after temporary threshold shift-inducing noise exposure was performed. The transcription factor Hepatocyte Nuclear Factor-4 alpha (HNF4α), which had not previously been studied in the context of cochlear response to noise, was identified as a hub of a top-ranking network. Hnf4α expression and localization using quantitative RT-PCR and in situ hybridization, respectively, were described in adolescent and adult mice exposed to neuropathic noise levels in adolescence. Isoforms α3 and α12 in the cochlea were also identified. At every age examined, Hnf4α mRNA expression in the cochlear apex was similar to expression in the base. Hnf4α expression was evident in select cochlear cells, including spiral ganglion neurons (SGNs) and hair cells, and was significantly upregulated from 6 to 70 weeks of age, especially in SGNs. This age-related Hnf4α upregulation was inhibited by neuropathic noise exposure in adolescence. Hnf4α silencing with shRNA transfection into auditory neuroblast cells (VOT-33) reduced cell viability, as measured with the MTT assay, suggesting that Hnf4α may be involved in SGN survival. Our results motivate future studies of HNF4α in cochlear pathophysiology, especially because HNF4α mutations and polymorphisms are associated with human diseases that may include hearing loss. © 2016 Wiley Periodicals, Inc. Develop Neurobiol 76: 1374-1386, 2016. © 2016 Wiley Periodicals, Inc.

  2. Factors contributing to communication skills development in cochlear implanted children.

    PubMed

    Ostojić, Sanja; Djoković, Sanja; Radić-šestić, Marina; Nikolić, Mina; Mikić, Branka; Mirić, Danica

    2015-08-01

    Over the last 10 years more than 300 persons received cochlear implant in Serbia and more than 90% of the recipients were children under 10 years of age. The program of cochlear implantation includes postoperative rehabilitation in which cognitive, integrative and developmental methods are used. The study was conducted to reveal factors affecting communication performance (CP) of cochlear implanted (Cl) children. Special attention was focused on the influence of the duration and intensity of rehabilitation and hearing age on further development of communication skills. A group of 30 CI children (13 boys and 17 girls) aged 2 to 5 years was enrolled in the study. All of the children had average intelligence and no other developmental disorder. They lived in families and attended rehabilitative seances 3 to 5 times a week. Their parents/caregivers answered structured questionnaire about functioning after pediatric cochlear implantation (FAPCI) and the results were the subject of detailed statistical analysis. Analysis of variance did not show any difference between the boys and the girls regarding FAPCI achievements (F(1, 28) = 2.909; p = 0.099) and age aberration in CP score (F(1,28) = 0.114, p = 0.738). Correlation analysis showed a statistically significant difference in FAPCI scores related to hearing age and duration of rehabilitation. Regression analysis (enter method) showed that model consisting of indipendent variables significantly contributed to prediction of overall FAPCI scores and Adjusted R2 value could explain 32% difference in communication skills of participants in this study. Communication skills of CI children evaluated by FAPCI are falling behind normatives for normal hearing children 18.6 months on the average. Hearing age, duration and intensity of rehabilitation have positive predictive value for communication skills development. Later identification of hearing loss and later cochlear implantation lead to delayed development of communication

  3. The intensity-pitch relation revisited: monopolar versus bipolar cochlear stimulation.

    PubMed

    Arnoldner, Christoph; Riss, Dominik; Kaider, Alexandra; Mair, Alois; Wagenblast, Jens; Baumgartner, Wolf-Dieter; Gstöttner, Wolfgang; Hamzavi, Jafar-Sasan

    2008-09-01

    The very high speech perception scores now being achieved with cochlear implants have led to demands for similar levels of achievement in music perception and perception in noisy environments. One of the crucial factors in these fields is pitch perception. The aim of the present study was to investigate the extent to which pitch perception is influenced by the intensity of the stimulus, through the use of different stimulation modes (monopolar, bipolar) and different electrodes (lateral and perimodiolar). Sixteen postlingually deafened patients with an average implant use of 3.1 years were included in this study. All patients were using a Cochlear (CI24M, CI24R, CI24RE) cochlear implant. Subjects were asked to compare the pitch of an intensity-constant reference tone with the pitch of a test tone of varying intensity. The test was repeated for apical, mediocochlear, and basal channel locations, and also for monopolar and bipolar stimulation. It was found that in monopolar stimulation 87.5% and in bipolar stimulation 85.7% of the patients perceived a clear pitch change with changing intensity of the stimulus (Spearman correlation coefficients r < -0.3 or r > 0.3, respectively). A total of 73.1% of these patients perceived lower pitches with increasing intensity, 26.9% reported the opposite effect. No statistically significant difference in the intensity-pitch correlation could be found between mono- and bipolar stimulation. Neither the mean dynamic range nor the type of electrode used was found to be related to the correlation coefficient. Although the majority of today's cochlear implant recipients perform well and the intensity-pitch relation in cochlear implant recipients is still poorly understood, rising demands on speech-coding strategies may soon make a compensation of the pitch shifts desirable. Although the results of our study tend to argue against a peripheral mechanism, the exact origin of this phenomenon remains unclear.

  4. Simultaneous Communication Supports Learning in Noise by Cochlear Implant Users

    PubMed Central

    Blom, Helen C.; Marschark, Marc; Machmer, Elizabeth

    2017-01-01

    Objectives This study sought to evaluate the potential of using spoken language and signing together (simultaneous communication, SimCom, sign-supported speech) as a means of improving speech recognition, comprehension, and learning by cochlear implant users in noisy contexts. Methods Forty eight college students who were active cochlear implant users, watched videos of three short presentations, the text versions of which were standardized at the 8th grade reading level. One passage was presented in spoken language only, one was presented in spoken language with multi-talker babble background noise, and one was presented via simultaneous communication with the same background noise. Following each passage, participants responded to 10 (standardized) open-ended questions designed to assess comprehension. Indicators of participants’ spoken language and sign language skills were obtained via self-reports and objective assessments. Results When spoken materials were accompanied by signs, scores were significantly higher than when materials were spoken in noise without signs. Participants’ receptive spoken language skills significantly predicted scores in all three conditions; neither their receptive sign skills nor age of implantation predicted performance. Discussion Students who are cochlear implant users typically rely solely on spoken language in the classroom. The present results, however, suggest that there are potential benefits of simultaneous communication for such learners in noisy settings. For those cochlear implant users who know sign language, the redundancy of speech and signs potentially can offset the reduced fidelity of spoken language in noise. Conclusion Accompanying spoken language with signs can benefit learners who are cochlear implant users in noisy situations such as classroom settings. Factors associated with such benefits, such as receptive skills in signed and spoken modalities, classroom acoustics, and material difficulty need to be

  5. Minimally-Invasive, Image-Guided Cochlear Implantation Surgery: First report of clinical implementation

    PubMed Central

    Labadie, Robert F; Balachandran, Ramya; Noble, Jack H; Blachon, Grégoire S; Mitchell, Jason E; Reda, Fitsum A; Dawant, Benoit M; Fitzpatrick, J Michael

    2015-01-01

    OBJECTIVE Minimally-invasive image-guided approach to cochlear implantation (CI) involves drilling a narrow, linear tunnel to the cochlea. Reported herein is the first clinical implementation of this approach. STUDY DESIGN Prospective, cohort study. METHODS On preoperative CT, a safe linear trajectory through the facial recess targeting the scala tympani was planned. Intraoperatively, fiducial markers were bone-implanted, a second CT was acquired, and the trajectory was transferred from preoperative to intraoperative CT. A customized microstereotactic frame was rapidly designed and constructed to constrain a surgical drill along the desired trajectory. Following sterilization, the frame was employed to drill the tunnel to the middle ear. After lifting a tympanomeatal flap and performing a cochleostomy, the electrode array was threaded through the drilled tunnel and into the cochlea. RESULTS Eight of nine patients were successfully implanted using the proposed approach with six insertions completely within scala tympani. Traditional mastoidectomy was performed on one patient following difficulty threading the electrode array via the narrow tunnel. Other difficulties encountered included use of the back-up implant when an electrode was dislodged during threading via the tunnel, tip fold-over, and facial nerve paresis (House-Brackmann II/VII at 12 months) secondary to heat during drilling. Average time of intervention was 182±36 minutes. CONCLUSION Minimally-invasive, image-guided CI is clinically achievable. Further clinical study is necessary to address technological difficulties during drilling and insertion and to assess potential benefits including decreased time of intervention, standardization of surgical intervention, and decreased tissue dissection potentially leading to shorter recovery and earlier implant activation. PMID:24272427

  6. Prevention and management of vascular complications in middle ear and cochlear implant surgery.

    PubMed

    Di Lella, Filippo; Falcioni, Maurizio; Piccinini, Silvia; Iaccarino, Ilaria; Bacciu, Andrea; Pasanisi, Enrico; Cerasti, Davide; Vincenti, Vincenzo

    2017-11-01

    The objective of this study is to illustrate prevention strategies and management of vascular complications from the jugular bulb (JB) and internal carotid artery (ICA) during middle ear surgery or cochlear implantation. The study design is retrospective case series. The setting is tertiary referral university hospital. Patients were included if presented pre- or intraoperative evidence of high-risk anatomical anomalies of ICA or JB during middle ear or cochlear implant surgery, intraoperative vascular injury, or revision surgery after the previous iatrogenic vascular lesions. The main outcome measures are surgical outcomes and complications rate. Ten subjects were identified: three underwent cochlear implant surgery and seven underwent middle ear surgery. Among the cochlear implant patients, two presented with anomalies of the JB impeding access to the cochlear lumen and one underwent revision surgery for incorrect positioning of the array in the carotid canal. Subtotal petrosectomy was performed in all cases. Anomalies of the JB were preoperatively identified in two patients with attic and external auditory canal cholesteatoma, respectively. In a patient, a high and dehiscent JB was found during myringoplasty, while another underwent revision surgery after iatrogenic injury of the JB. A dehiscent ICA complicated middle ear effusion in one case, while in another case, a carotid aneurysm determined a cholesterol granuloma. Rupture of a pseudoaneurysm of the ICA occurred in a child during second-stage surgery and required permanent balloon occlusion without neurological complications. Knowledge of normal anatomy and its variants and preoperative imaging are the basis for prevention of vascular complications during middle ear or cochlear implant surgery.

  7. Cochlear implant with a non-removable magnet: preliminary research at 3-T MRI.

    PubMed

    Dubrulle, F; Sufana Iancu, A; Vincent, C; Tourrel, G; Ernst, O

    2013-06-01

    To perform preliminary tests in vitro and with healthy volunteers to determine the 3-T MRI compatibility of a cochlear implant with a non-removable magnet. In the in vitro phase, we tested six implants for temperature changes and internal malfunctioning. We measured the demagnetisation of 65 internal magnets with different tilt angles between the implant's magnetic field (bi) and the main magnetic field (b0). In the in vivo phase, we tested 28 operational implants attached to the scalps of volunteers with the head in three different positions. The study did not find significant temperature changes or electronic malfunction in the implants tested in vitro. We found considerable demagnetisation of the cochlear implant magnets in the in vitro and in vivo testing influenced by the position of the magnet in the main magnetic field. We found that if the bi/b0 angle is <90°, there is no demagnetisation; if the bi/b0 angle is >90°, there is demagnetisation in almost 60 % of the cases. When the angle is around 90°, the risk of demagnetisation is low (6.6 %). The preliminary results on cochlear implants with non-removable magnets indicate the need to maintain the contraindication of passage through 3-T MRI. • Magnetic resonance imaging can affect cochlear implants and vice versa. • Demagnetisation of cochlear implant correlates with the angle between bi and b0. • The position of the head in the MRI influences the demagnetisation. • Three-Tesla MRI for cochlear implants is still contraindicated. • However some future solutions are discussed.

  8. Identification of Pure-Tone Audiologic Thresholds for Pediatric Cochlear Implant Candidacy: A Systematic Review.

    PubMed

    de Kleijn, Jasper L; van Kalmthout, Ludwike W M; van der Vossen, Martijn J B; Vonck, Bernard M D; Topsakal, Vedat; Bruijnzeel, Hanneke

    2018-05-24

    Although current guidelines recommend cochlear implantation only for children with profound hearing impairment (HI) (>90 decibel [dB] hearing level [HL]), studies show that children with severe hearing impairment (>70-90 dB HL) could also benefit from cochlear implantation. To perform a systematic review to identify audiologic thresholds (in dB HL) that could serve as an audiologic candidacy criterion for pediatric cochlear implantation using 4 domains of speech and language development as independent outcome measures (speech production, speech perception, receptive language, and auditory performance). PubMed and Embase databases were searched up to June 28, 2017, to identify studies comparing speech and language development between children who were profoundly deaf using cochlear implants and children with severe hearing loss using hearing aids, because no studies are available directly comparing children with severe HI in both groups. If cochlear implant users with profound HI score better on speech and language tests than those with severe HI who use hearing aids, this outcome could support adjusting cochlear implantation candidacy criteria to lower audiologic thresholds. Literature search, screening, and article selection were performed using a predefined strategy. Article screening was executed independently by 4 authors in 2 pairs; consensus on article inclusion was reached by discussion between these 4 authors. This study is reported according to the Preferred Reporting Items for Systematic Review and Meta-analysis (PRISMA) statement. Title and abstract screening of 2822 articles resulted in selection of 130 articles for full-text review. Twenty-one studies were selected for critical appraisal, resulting in selection of 10 articles for data extraction. Two studies formulated audiologic thresholds (in dB HLs) at which children could qualify for cochlear implantation: (1) at 4-frequency pure-tone average (PTA) thresholds of 80 dB HL or greater based on speech

  9. Effects of sustained release dexamethasone hydrogels in hearing preservation cochlear implantation.

    PubMed

    Honeder, Clemens; Zhu, Chengjing; Schöpper, Hanna; Gausterer, Julia Clara; Walter, Manuel; Landegger, Lukas David; Saidov, Nodir; Riss, Dominik; Plasenzotti, Roberto; Gabor, Franz; Arnoldner, Christoph

    2016-11-01

    It has been shown that glucocorticoids reduce the hearing threshold shifts associated with cochlear implantation. Previous studies evaluated the administration of glucocorticoids immediately before surgery or the repeated pre- or perioperative systemic application of glucocorticoids. The aim of this study was to evaluate the effects of a sustained release dexamethasone hydrogel in hearing preservation cochlear implantation. To address this issue, a guinea pig model of cochlear implantation was used. 30 normal hearing pigmented guinea pigs were randomized into a group receiving a single dose of a dexamethasone/poloxamer407 hydrogel one day prior to surgery, a second group receiving the hydrogel seven days prior to surgery and a control group. A silicone cochlear implant electrode designed for the use in guinea pigs was inserted to a depth of 5 mm through a cochleostomy. Compound action potentials of the auditory nerve (frequency range 0.5-32 kHz) were measured preoperatively, directly postoperatively and on postoperative days 3, 7, 14, 21 and 28. Following the last audiometry, temporal bones were harvested and histologically evaluated. Dexamethasone hydrogel application one day prior to surgery resulted in significantly reduced hearing threshold shifts at low, middle and high frequencies measured at postoperative day 28 (p < 0.05). Application of the hydrogel seven days prior to surgery did not show such an effect. Dexamethasone application one day prior to surgery resulted in increased outer hair cell counts in the cochlear apex and in reduced spiral ganglion cell counts in the basal and middle turn of the cochlea, a finding that was associated with a higher rate of electrode translocation in this group. In this study, we were able to demonstrate functional benefits of a single preoperative intratympanic application of a sustained release dexamethasone hydrogel in a guinea pig model of cochlear implantation. Copyright © 2016 The Authors. Published by Elsevier

  10. Effects of Hearing Preservation on Psychophysical Responses to Cochlear Implant Stimulation

    PubMed Central

    Kang, Stephen Y.; Colesa, Deborah J.; Swiderski, Donald L.; Su, Gina L.; Raphael, Yehoash

    2009-01-01

    Previous studies have shown that residual acoustic hearing supplements cochlear implant function to improve speech recognition in noise as well as perception of music. The current study had two primary objectives. First, we sought to determine how cochlear implantation and electrical stimulation over a time period of 14 to 21 months influence cochlear structures such as hair cells and spiral ganglion neurons. Second, we sought to investigate whether the structures that provide acoustic hearing also affect the perception of electrical stimulation. We compared psychophysical responses to cochlear implant stimulation in two groups of adult guinea pigs. Group I (11 animals) received a cochlear implant in a previously untreated ear, while group II (ten animals) received a cochlear implant in an ear that had been previously infused with neomycin to destroy hearing. Psychophysical thresholds were measured in response to pulse-train and sinusoidal stimuli. Histological analysis of all group I animals and a subset of group II animals was performed. Nine of the 11 group I animals showed survival of the organ of Corti and spiral ganglion neurons adjacent to the electrode array. All group I animals showed survival of these elements in regions apical to the electrode array. Group II animals that were examined histologically showed complete loss of the organ of Corti in regions adjacent and apical to the electrode array and severe spiral ganglion neuron loss, consistent with previous reports for neomycin-treated ears. Behaviorally, group II animals had significantly lower thresholds than group I animals in response to 100 Hz sinusoidal stimuli. However, group I animals had significantly lower thresholds than group II animals in response to pulse-train stimuli (0.02 ms/phase; 156 to 5,000 pps). Additionally, the two groups showed distinct threshold versus pulse rate functions. We hypothesize that the differences in detection thresholds between groups are caused by the

  11. A cochlear implant fabricated using a bulk silicon-surface micromachining process

    NASA Astrophysics Data System (ADS)

    Bell, Tracy Elizabeth

    1999-11-01

    This dissertation presents the design and fabrication of two generations of a silicon microelectrode array for use in a cochlear implant. A cochlear implant is a device that is inserted into the inner ear and uses electrical stimulation to provide sound sensations to the profoundly deaf. The first-generation silicon cochlear implant is a passive device fabricated using silicon microprobe technology developed at the University of Michigan. It contains twenty-two iridium oxide (IrO) stimulating sites that are 250 mum in diameter and spaced at 750 mum intervals. In-vivo recordings were made in guinea pig auditory cortex in response to electrical stimulation with this device, verifying its ability to electrically evoke an auditory response. Auditory thresholds as low as 78 muA were recorded. The second-generation implant is a thirty-two site, four-channel device with on-chip CMOS site-selection circuitry and integrated position sensing. It was fabricated using a novel bulk silicon surface micromachining process which was developed as a part of this dissertation work. While the use of semiconductor technology offers many advantages in fabricating cochlear implants over the methods currently used, it was felt that even further advantages could be gained by developing a new micromachining process which would allow circuitry to be distributed along the full length of the cochlear implant substrate. The new process uses electropolishing of an n+ bulk silicon sacrificial layer to undercut and release n- epitaxial silicon structures from the wafer. An extremely abrupt etch-stop between the n+ and n- silicon is obtained, with no electropolishing taking place in the n-type silicon that is doped lower than 1 x 1017 cm-3 in concentration. Lateral electropolishing rates of up to 50 mum/min were measured using this technique, allowing one millimeter-wide structures to be fully undercut in as little as 10 minutes. The new micromachining process was integrated with a standard p

  12. Cochlear Damages Caused by Vibration Exposure

    PubMed Central

    Moussavi Najarkola, Seyyed Ali; Khavanin, Ali; Mirzaei, Ramazan; Salehnia, Mojdeh; Muhammadnejad, Ahad

    2013-01-01

    Background Many industrial devices have an excessive vibration which can affect human body systems. The effect of vibration on cochlear histology has been as a debatable problem in occupational health and medicine. Objectives Due to limitation present in human studies, the research was conducted to survey the influence of vibration on cochlear histology in an animal model. Materials and Methods Twelve albino rabbits were experimented as: Vibration group (n = 6; exposed to 1.0 m.s-2 r.m.s vertical whole-body vibration at 4 - 8 Hz for 8 hours per day during 5 consecutive days) versus Control group (n = 6; the same rabbits without vibration exposure). After finishing the exposure scenario, all rabbits were killed by CO2 inhalation; their cochleae were extracted and fixed in 10% formaldehyde for 48 hours, decalcified by 10% nitric acid for 24 hours. Specimens were dehydrated, embedded, sectioned 5 µm thick and stained with Hematoxylin and Eosin for light microscopy observations. Results Severely hydropic degenerated and vacuolated inner hair cells (IHCs) were observed in vibration group compared to the control group. Inter and intracellular edema was appeared in supporting cells (SC). Nuclei of outer hair cells (OHCs) seemed to be pyknotic. Slightly thickened basilar membrane (BM) was probably implied to inter cellular edematous. Tectorial Membrane (TM) was not affected pathologically. Conclusions Whole-body vibration could cause cochlear damages in male rabbits, though vibration-induced auditory functional effects might be resulted as subsequent outcome of prolonged high level vibration exposures. PMID:24616783

  13. Age-Dependent Cost-Utility of Pediatric Cochlear Implantation

    PubMed Central

    Semenov, Yevgeniy R.; Yeh, Susan T.; Seshamani, Meena; Wang, Nae-Yuh; Tobey, Emily A.; Eisenberg, Laurie S.; Quittner, Alexandra L.; Frick, Kevin D.; Niparko, John K.

    2013-01-01

    Objective Cochlear implantation has become the mainstay of treatment for children with severe-to-profound sensorineural hearing loss (SNHL). Yet, despite mounting evidence on the clinical benefits of early implantation, little data are available on the long-term societal benefits and comparative effectiveness of this procedure across various ages of implantation--a choice parameter for parents and clinicians with high prognostic value for clinical outcome. As such, the aim of the current study is to evaluate a model of the consequences of the timing of this intervention from a societal economic perspective. Average cost-utility of pediatric cochlear implantation by age at intervention will be analyzed. Design Prospective, longitudinal assessment of health-utility and educational placement outcomes in 175 children recruited from 6 US centers between November 2002 and December 2004, who had severe-to-profound SNHL onset within 1 year of age, underwent cochlear implantation before 5 years of age, and had up to 6 years of post-implant follow-up that ended in November 2008 to December 2011. Costs of care were collected retrospectively and stratified by pre-operative, operative, and post-operative expenditures. Incremental costs and benefits of implantation were compared between the three age groups and relative to a non-implantation baseline. Results Children implanted at <18 months of age gained an average of 10.7 QALYs over their projected lifetime as compared to 9.0 and 8.4 QALYs for those implanted between 18 and 36 months and at >36 months of age, respectively. Medical and surgical complication rates were not significantly different between the 3 age groups. Additionally, mean lifetime costs of implantation were similar between the 3 groups, at approximately $2,000/child/year (77.5 year life expectancy), yielding costs of $14,996, $17,849, and $19,173 per QALY for the youngest, middle, and oldest implant age groups, respectively. Full mainstream classroom

  14. Melorheostosis of the hand with complicating bony spur formation and bursal inflammation: diagnosis and treatment.

    PubMed

    Ameen, S; Nagy, L; Gerich, U; Anderson, S E

    2002-08-01

    A 37-year old woman presented with intolerable pain associated with a slowly growing mass on the dorsum of the right hand. The radiographs were characteristic of melorheostosis involving the third and fourth metacarpals, with a cortical bony projection extending from the base of the third metacarpal eroding slightly into the fourth metacarpal, associated with bursal formation. Magnetic resonance imaging (MRI) demonstrated an inflamed bursal collection adjacent to the spur. This region corresponded to the patient's severe clinical, focal pain. To our knowledge, this is the first case report in which melorheostosis of the hand has been associated with bony spur formation and complicated by an inflamed bursa.

  15. Resistance of Gerbil Auditory Function to Reversible Decrease in Cochlear Blood Flow.

    PubMed

    El Afia, Fahd; Giraudet, Fabrice; Gilain, Laurent; Mom, Thierry; Avan, Paul

    2017-01-01

    The objective was to design in gerbils a model of reversible decrease in cochlear blood flow (CBF) and analyze its influence on cochlear function. In Mongolian gerbils injected with ferromagnetic microbeads, a magnet placed near the porus acusticus allowed CBF to be manipulated. The cochlear microphonic potential (CM) from the basal cochlea was monitored by a round-window electrode. In 13 of the 20 successfully injected gerbils, stable CBF reduction was obtained for 11.5 min on average. The CM was affected only when CBF fell to less than 60% of its baseline, yet remained >40% of its initial level in about 2/3 of such cases. After CBF restoration, CM recovery was fast and usually complete. Reduced CM came with a 35- to 45-dB threshold elevation of neural responses determined by compound action potentials. This method allowing reversible changes of CBF confirms the robustness of cochlear function to decreased CBF. It can be used to study whether a hypovascularized cochlea is abnormally sensitive to stress. © 2017 S. Karger AG, Basel.

  16. Recognition and Comprehension of "Narrow Focus" by Young Adults with Prelingual Hearing Loss Using Hearing Aids or Cochlear Implants

    ERIC Educational Resources Information Center

    Segal, Osnat; Kishon-Rabin, Liat

    2017-01-01

    Purpose: The stressed word in a sentence (narrow focus [NF]) conveys information about the intent of the speaker and is therefore important for processing spoken language and in social interactions. The ability of participants with severe-to-profound prelingual hearing loss to comprehend NF has rarely been investigated. The purpose of this study…

  17. A longitudinal study of the bilateral benefit in children with bilateral cochlear implants.

    PubMed

    Asp, Filip; Mäki-Torkko, Elina; Karltorp, Eva; Harder, Henrik; Hergils, Leif; Eskilsson, Gunnar; Stenfelt, Stefan

    2015-02-01

    To study the development of the bilateral benefit in children using bilateral cochlear implants by measurements of speech recognition and sound localization. Bilateral and unilateral speech recognition in quiet, in multi-source noise, and horizontal sound localization was measured at three occasions during a two-year period, without controlling for age or implant experience. Longitudinal and cross-sectional analyses were performed. Results were compared to cross-sectional data from children with normal hearing. Seventy-eight children aged 5.1-11.9 years, with a mean bilateral cochlear implant experience of 3.3 years and a mean age of 7.8 years, at inclusion in the study. Thirty children with normal hearing aged 4.8-9.0 years provided normative data. For children with cochlear implants, bilateral and unilateral speech recognition in quiet was comparable whereas a bilateral benefit for speech recognition in noise and sound localization was found at all three test occasions. Absolute performance was lower than in children with normal hearing. Early bilateral implantation facilitated sound localization. A bilateral benefit for speech recognition in noise and sound localization continues to exist over time for children with bilateral cochlear implants, but no relative improvement is found after three years of bilateral cochlear implant experience.

  18. Speaker normalization for chinese vowel recognition in cochlear implants.

    PubMed

    Luo, Xin; Fu, Qian-Jie

    2005-07-01

    Because of the limited spectra-temporal resolution associated with cochlear implants, implant patients often have greater difficulty with multitalker speech recognition. The present study investigated whether multitalker speech recognition can be improved by applying speaker normalization techniques to cochlear implant speech processing. Multitalker Chinese vowel recognition was tested with normal-hearing Chinese-speaking subjects listening to a 4-channel cochlear implant simulation, with and without speaker normalization. For each subject, speaker normalization was referenced to the speaker that produced the best recognition performance under conditions without speaker normalization. To match the remaining speakers to this "optimal" output pattern, the overall frequency range of the analysis filter bank was adjusted for each speaker according to the ratio of the mean third formant frequency values between the specific speaker and the reference speaker. Results showed that speaker normalization provided a small but significant improvement in subjects' overall recognition performance. After speaker normalization, subjects' patterns of recognition performance across speakers changed, demonstrating the potential for speaker-dependent effects with the proposed normalization technique.

  19. Examining the communication skills of a young cochlear implant pioneer.

    PubMed

    Connor, Carol McDonald

    2006-01-01

    The purpose of this longitudinal case study was to closely examine one deaf child's experience with a cochlear implant and his speech, language, and communication skills from kindergarten through middle and high school using both developmental and sociocultural frameworks. The target child was one of the first children to receive a cochlear implant in the United States in 1988, when he was 5 years of age. The developmental analysis revealed that prior to receiving a cochlear implant the child demonstrated profound delays in speech and language skill development. His speech and language skills grew slowly during the first 3-4 years following implantation, very rapidly from about 5 through 7 years postimplantation, then slowed to rates that were highly similar to same-age peers with normal hearing. The sociocultural analysis revealed that the child's communicative competence improved; that he used sign language but use of sign language decreased as his oral communication skills improved; that as his oral communication skills improved, the adults talked and directed the topic of conversation less frequently; and that topics became less concrete and more personal over time. The results of this study indicate that we may learn more about how to support children who use cochlear implants by examining what they are saying as well as how they are saying it.

  20. Biohybrid cochlear implants in human neurosensory restoration.

    PubMed

    Roemer, Ariane; Köhl, Ulrike; Majdani, Omid; Klöß, Stephan; Falk, Christine; Haumann, Sabine; Lenarz, Thomas; Kral, Andrej; Warnecke, Athanasia

    2016-10-07

    The success of cochlear implantation may be further improved by minimizing implantation trauma. The physical trauma of implantation and subsequent immunological sequelae can affect residual hearing and the viability of the spiral ganglion. An ideal electrode should therefore decrease post-implantation trauma and provide support to the residual spiral ganglion population. Combining a flexible electrode with cells producing and releasing protective factors could present a potential means to achieve this. Mononuclear cells obtained from bone marrow (BM-MNC) consist of mesenchymal and hematopoietic progenitor cells. They possess the innate capacity to induce repair of traumatized tissue and to modulate immunological reactions. Human bone marrow was obtained from the patients that received treatment with biohybrid electrodes. Autologous mononuclear cells were isolated from bone marrow (BM-MNC) by centrifugation using the Regenlab™ THT-centrifugation tubes. Isolated BM-MNC were characterised using flow cytometry. In addition, the release of cytokines was analysed and their biological effect tested on spiral ganglion neurons isolated from neonatal rats. Fibrin adhesive (Tisseal™) was used for the coating of silicone-based cochlear implant electrode arrays for human use in order to generate biohybrid electrodes. Toxicity of the fibrin adhesive and influence on insertion, as well on the cell coating, was investigated. Furthermore, biohybrid electrodes were implanted in three patients. Human BM-MNC release cytokines, chemokines, and growth factors that exert anti-inflammatory and neuroprotective effects. Using fibrin adhesive as a carrier for BM-MNC, a simple and effective cell coating procedure for cochlear implant electrodes was developed that can be utilised on-site in the operating room for the generation of biohybrid electrodes for intracochlear cell-based drug delivery. A safety study demonstrated the feasibility of autologous progenitor cell transplantation in

  1. Cochlear implantation in the world's largest medical device market: utilization and awareness of cochlear implants in the United States.

    PubMed

    Sorkin, Donna L

    2013-03-01

    Provision of cochlear implants (CIs) for those within the criteria for implantation remains lower in the United States than in some other developed nations. When adults and children are grouped together, the rate of utilization/provision remains low at around 6%. For children, the provision rate is about 50% of those who could benefit from an implant, compared with figures of about 90% for the Flanders part of Belgium, the United Kingdom and other European countries. The probable reasons for this underprovision include: low awareness of the benefits of CIs among the population; low awareness among health-care professionals; the lack of specific referral pathways; some political issues relating to the Deaf Community; and financial issues related to health provision. Such financial issues result in situations which either fail to provide for access to implants or provide too low a level of the necessary funding, especially for low-income individuals covered by public health-care programs such as Medicaid. These issues might be mitigated by adoption and publication of standards for best clinical practices for CI provision, availability of current cost-effectiveness data, and the existence of an organization dedicated to cochlear implantation. Such an organization, the American Cochlear Implant Alliance (ACI Alliance), was recently organized and is described in the paper by Niparko et al. in this Supplement.

  2. Investigation of Notch Signaling during Spontaneous Regeneration of Cochlear Hair Cells

    DTIC Science & Technology

    2016-10-01

    AWARD NUMBER: W81XWH-15-1-0475 TITLE: Investigation of Notch Signaling during Spontaneous Regeneration of Cochlear Hair Cells PRINCIPAL...Sep 2016 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER Investigation of Notch Signaling during Spontaneous Regeneration of Cochlear Hair Cells 5b...inherent to military settings. These noise exposures damage and kill sensory hair cells (HCs) found in the cochlea of the inner ear, resulting in permanent

  3. Pneumatocyst, mimicking a sclerotic bony lesion on magnetic resonance imaging.

    PubMed

    Zarei, Fariba; Iranpour, Pooya

    2010-04-01

    Intravertebral pneumatocyst is an uncommon benign lesion, not related to conditions, such as osteomyelitis and postsurgical state, with only a few cases reported in the literature. The purpose of the study was to report a case of cervical pneumatocyst resembling a sclerotic lesion on magnetic resonance imaging (MRI) and review of literature. The study was designed to be a case report. The patient chosen was a 48-year-old woman with the chief complaint of neck pain and bilateral upper extremity paresthesia of 6 months duration. Neurologic examination and results of routine hematologic and biochemical examination were normal. Cervical spine MRI revealed a low signal bony lesion on T1 and T2 images. Considering the signal characteristics, initial diagnosis of sclerosis was made. Reviewing the cervical X-ray, a round faint lytic lesion was detected. Correlation with cervical computed tomography scan showed the lesion being of air density, compatible with the diagnosis of pneumatocyst. Intraosseous pneumatocyst of cervical spine is a benign finding, which needs no specific treatment; however, it must be included in the differential diagnosis of lucent vertebral lesions seen on conventional radiography and should be differentiated from bony neoplasm and osteomyelitis by its characteristic imaging findings.

  4. Cochlear Implant Outcomes and Genetic Mutations in Children with Ear and Brain Anomalies

    PubMed Central

    Busi, Micol; Rosignoli, Monica; Minazzi, Federica; Trevisi, Patrizia; Aimoni, Claudia; Calzolari, Ferdinando; Martini, Alessandro

    2015-01-01

    Background. Specific clinical conditions could compromise cochlear implantation outcomes and drastically reduce the chance of an acceptable development of perceptual and linguistic capabilities. These conditions should certainly include the presence of inner ear malformations or brain abnormalities. The aims of this work were to study the diagnostic value of high resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in children with sensorineural hearing loss who were candidates for cochlear implants and to analyse the anatomic abnormalities of the ear and brain in patients who underwent cochlear implantation. We also analysed the effects of ear malformations and brain anomalies on the CI outcomes, speculating on their potential role in the management of language developmental disorders. Methods. The present study is a retrospective observational review of cochlear implant outcomes among hearing-impaired children who presented ear and/or brain anomalies at neuroimaging investigations with MRI and HRCT. Furthermore, genetic results from molecular genetic investigations (GJB2/GJB6 and, additionally, in selected cases, SLC26A4 or mitochondrial-DNA mutations) on this study group were herein described. Longitudinal and cross-sectional analysis was conducted using statistical tests. Results. Between January 1, 1996 and April 1, 2012, at the ENT-Audiology Department of the University Hospital of Ferrara, 620 cochlear implantations were performed. There were 426 implanted children at the time of the present study (who were <18 years). Among these, 143 patients (64 females and 79 males) presented ear and/or brain anomalies/lesions/malformations at neuroimaging investigations with MRI and HRCT. The age of the main study group (143 implanted children) ranged from 9 months and 16 years (average = 4.4; median = 3.0). Conclusions. Good outcomes with cochlear implants are possible in patients who present with inner ear or brain abnormalities, even if central

  5. Cochlear Implant Outcomes and Genetic Mutations in Children with Ear and Brain Anomalies.

    PubMed

    Busi, Micol; Rosignoli, Monica; Castiglione, Alessandro; Minazzi, Federica; Trevisi, Patrizia; Aimoni, Claudia; Calzolari, Ferdinando; Granieri, Enrico; Martini, Alessandro

    2015-01-01

    Specific clinical conditions could compromise cochlear implantation outcomes and drastically reduce the chance of an acceptable development of perceptual and linguistic capabilities. These conditions should certainly include the presence of inner ear malformations or brain abnormalities. The aims of this work were to study the diagnostic value of high resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in children with sensorineural hearing loss who were candidates for cochlear implants and to analyse the anatomic abnormalities of the ear and brain in patients who underwent cochlear implantation. We also analysed the effects of ear malformations and brain anomalies on the CI outcomes, speculating on their potential role in the management of language developmental disorders. The present study is a retrospective observational review of cochlear implant outcomes among hearing-impaired children who presented ear and/or brain anomalies at neuroimaging investigations with MRI and HRCT. Furthermore, genetic results from molecular genetic investigations (GJB2/GJB6 and, additionally, in selected cases, SLC26A4 or mitochondrial-DNA mutations) on this study group were herein described. Longitudinal and cross-sectional analysis was conducted using statistical tests. Between January 1, 1996 and April 1, 2012, at the ENT-Audiology Department of the University Hospital of Ferrara, 620 cochlear implantations were performed. There were 426 implanted children at the time of the present study (who were <18 years). Among these, 143 patients (64 females and 79 males) presented ear and/or brain anomalies/lesions/malformations at neuroimaging investigations with MRI and HRCT. The age of the main study group (143 implanted children) ranged from 9 months and 16 years (average = 4.4; median = 3.0). Good outcomes with cochlear implants are possible in patients who present with inner ear or brain abnormalities, even if central nervous system anomalies represent a

  6. Large vestibular aqueduct syndrome: Impedance changes over time with different cochlear implant electrode arrays.

    PubMed

    Powell, Harry R F; Birman, Catherine S

    2015-01-01

    The aim of this study was to assess if large vestibular aqueduct syndrome (LVAS), with the increase in perilymphatic pressure, affects impedance changes over time with different types of Cochlear(®) implant electrode arrays Contour, Straight, and CI 422. To report speech perception outcomes for these cochlear implant recipients. Retrospective case review of impedance levels and categories of auditory performance. Impedance data were collected at switch on, 1 month, 3, 6, 12, and 24 months after cochlear implantation and compared with control (non-LVAS cochlear implant recipient) data for each array type. Forty-seven patients with exclusive LVAS and no other vestibulocochlear abnormalities or other identifiable cause of deafness were eligible for inclusion in the study. In LVAS patients, there was a significant difference in impedance between the three types of device (P < 0.0001). Time since switch on was associated with a decrease in impedance for all three devices (P < 0.0001). The mean impedance reduced between switch on and 1 month and remained relatively constant thereafter. Sound variation with softening of sounds was seen in four CI 422 (Straight Research Array) recipients due to ongoing fluctuations in electrode compliance. For all three array types, there was no significant difference in the mean impedance between the LVAS patients and controls over the first 12 months. In keeping with previous studies cochlear implant recipients with LVAS hear very well through the cochlear implant.

  7. Technological, biological, and acoustical constraints to music perception in cochlear implant users.

    PubMed

    Limb, Charles J; Roy, Alexis T

    2014-02-01

    Despite advances in technology, the ability to perceive music remains limited for many cochlear implant users. This paper reviews the technological, biological, and acoustical constraints that make music an especially challenging stimulus for cochlear implant users, while highlighting recent research efforts to overcome these shortcomings. The limitations of cochlear implant devices, which have been optimized for speech comprehension, become evident when applied to music, particularly with regards to inadequate spectral, fine-temporal, and dynamic range representation. Beyond the impoverished information transmitted by the device itself, both peripheral and central auditory nervous system deficits are seen in the presence of sensorineural hearing loss, such as auditory nerve degeneration and abnormal auditory cortex activation. These technological and biological constraints to effective music perception are further compounded by the complexity of the acoustical features of music itself that require the perceptual integration of varying rhythmic, melodic, harmonic, and timbral elements of sound. Cochlear implant users not only have difficulty perceiving spectral components individually (leading to fundamental disruptions in perception of pitch, melody, and harmony) but also display deficits with higher perceptual integration tasks required for music perception, such as auditory stream segregation. Despite these current limitations, focused musical training programs, new assessment methods, and improvements in the representation and transmission of the complex acoustical features of music through technological innovation offer the potential for significant advancements in cochlear implant-mediated music perception. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Dynamics of cochlear nonlinearity: Automatic gain control or instantaneous damping?

    PubMed

    Altoè, Alessandro; Charaziak, Karolina K; Shera, Christopher A

    2017-12-01

    Measurements of basilar-membrane (BM) motion show that the compressive nonlinearity of cochlear mechanical responses is not an instantaneous phenomenon. For this reason, the cochlear amplifier has been thought to incorporate an automatic gain control (AGC) mechanism characterized by a finite reaction time. This paper studies the effect of instantaneous nonlinear damping on the responses of oscillatory systems. The principal results are that (i) instantaneous nonlinear damping produces a noninstantaneous gain control that differs markedly from typical AGC strategies; (ii) the kinetics of compressive nonlinearity implied by the finite reaction time of an AGC system appear inconsistent with the nonlinear dynamics measured on the gerbil basilar membrane; and (iii) conversely, those nonlinear dynamics can be reproduced using an harmonic oscillator with instantaneous nonlinear damping. Furthermore, existing cochlear models that include instantaneous gain-control mechanisms capture the principal kinetics of BM nonlinearity. Thus, an AGC system with finite reaction time appears neither necessary nor sufficient to explain nonlinear gain control in the cochlea.

  9. Comparison between bilateral cochlear implants and Neurelec Digisonic(®) SP Binaural cochlear implant: speech perception, sound localization and patient self-assessment.

    PubMed

    Bonnard, Damien; Lautissier, Sylvie; Bosset-Audoit, Amélie; Coriat, Géraldine; Beraha, Max; Maunoury, Antoine; Martel, Jacques; Darrouzet, Vincent; Bébéar, Jean-Pierre; Dauman, René

    2013-01-01

    An alternative to bilateral cochlear implantation is offered by the Neurelec Digisonic(®) SP Binaural cochlear implant, which allows stimulation of both cochleae within a single device. The purpose of this prospective study was to compare a group of Neurelec Digisonic(®) SP Binaural implant users (denoted BINAURAL group, n = 7) with a group of bilateral adult cochlear implant users (denoted BILATERAL group, n = 6) in terms of speech perception, sound localization, and self-assessment of health status and hearing disability. Speech perception was assessed using word recognition at 60 dB SPL in quiet and in a 'cocktail party' noise delivered through five loudspeakers in the hemi-sound field facing the patient (signal-to-noise ratio = +10 dB). The sound localization task was to determine the source of a sound stimulus among five speakers positioned between -90° and +90° from midline. Change in health status was assessed using the Glasgow Benefit Inventory and hearing disability was evaluated with the Abbreviated Profile of Hearing Aid Benefit. Speech perception was not statistically different between the two groups, even though there was a trend in favor of the BINAURAL group (mean percent word recognition in the BINAURAL and BILATERAL groups: 70 vs. 56.7% in quiet, 55.7 vs. 43.3% in noise). There was also no significant difference with regard to performance in sound localization and self-assessment of health status and hearing disability. On the basis of the BINAURAL group's performance in hearing tasks involving the detection of interaural differences, implantation with the Neurelec Digisonic(®) SP Binaural implant may be considered to restore effective binaural hearing. Based on these first comparative results, this device seems to provide benefits similar to those of traditional bilateral cochlear implantation, with a new approach to stimulate both auditory nerves. Copyright © 2013 S. Karger AG, Basel.

  10. Hearing Preservation Outcomes With a Mid-Scala Electrode in Cochlear Implantation.

    PubMed

    Hunter, Jacob B; Gifford, René H; Wanna, George B; Labadie, Robert F; Bennett, Marc L; Haynes, David S; Rivas, Alejandro

    2016-03-01

    To evaluate hearing preservation (HP) outcomes in adult cochlear implant recipients with a mid-scala electrode. Tertiary academic center. Adult patients implanted with a mid-scala electrode between May 2013 and July 2015. Cochlear implantation. Age, sex, surgical approach, residual hearing changes post cochlear implantation, HP rates using different published classifications, and speech perception scores. Fifty ears for 47 patients (mean age, 58.2 yr; range, 23-86) were implanted with the electrode. Recognizing that not all patients were true HP candidates and/or underwent generally accepted HP surgical techniques, 39 ears had preoperative low-frequency hearing (audiometric threshold ≤ 85dB HL at 250Hz), 24 preserved acoustic hearing postoperatively (75.0%). Patients who had preserved acoustic hearing were implanted via round window (N = 18), extended round window (N = 4), or via cochleostomy (N = 2) approaches. Mean threshold elevation for low-frequency pure-tone average (125, 250, and 500  Hz) was 20.2  dB after surgery. 43.8% of patients had aidable low-frequency hearing at activation, 30.0% at 6-months postoperatively, and 30.8% 1-year postopera tively. Using a formula outlined by Skarzynski and colleagues, at 6-months postoperatively, 15.0% of patients had complete HP, whereas 40.0% had partial HP. At 1-year, these percentages decreased to 0% and 38.5%, respectively. Age, type of approach, and perioperative steroid use were not correlated with HP outcomes at activation and 6-months postoperatively (p > 0.05). The mid-scala electrode evaluated allows preservation of low-frequency hearing in patients undergoing cochlear implantation at rates and degrees of preservation close to other reports in the cochlear implant literature.

  11. Intracochlear Scala Media Pressure Measurement: Implications for Models of Cochlear Mechanics

    PubMed Central

    Kale, Sushrut S.; Olson, Elizabeth S.

    2015-01-01

    Models of the active cochlea build upon the underlying passive mechanics. Passive cochlear mechanics is based on physical and geometrical properties of the cochlea and the fluid-tissue interaction between the cochlear partition and the surrounding fluid. Although the fluid-tissue interaction between the basilar membrane and the fluid in scala tympani (ST) has been explored in both active and passive cochleae, there was no experimental data on the fluid-tissue interaction on the scala media (SM) side of the partition. To this aim, we measured sound-evoked intracochlear pressure in SM close to the partition using micropressure sensors. All the SM pressure data are from passive cochleae, likely because the SM cochleostomy led to loss of endocochlear potential. Thus, these experiments are studies of passive cochlear mechanics. SM pressure close to the tissue showed a pattern of peaks and notches, which could be explained as an interaction between fast and slow (i.e., traveling wave) pressure modes. In several animals SM and ST pressure were measured in the same cochlea. Similar to previous studies, ST-pressure was dominated by a slow, traveling wave mode at stimulus frequencies in the vicinity of the best frequency of the measurement location, and by a fast mode above best frequency. Antisymmetric pressure between SM and ST supported the classic single-partition cochlear models, or a dual-partition model with tight coupling between partitions. From the SM and ST pressure we calculated slow and fast modes, and from active ST pressure we extrapolated the passive findings to the active case. The passive slow mode estimated from SM and ST data was low-pass in nature, as predicted by cochlear models. PMID:26682824

  12. Visual activity predicts auditory recovery from deafness after adult cochlear implantation.

    PubMed

    Strelnikov, Kuzma; Rouger, Julien; Demonet, Jean-François; Lagleyre, Sebastien; Fraysse, Bernard; Deguine, Olivier; Barone, Pascal

    2013-12-01

    Modern cochlear implantation technologies allow deaf patients to understand auditory speech; however, the implants deliver only a coarse auditory input and patients must use long-term adaptive processes to achieve coherent percepts. In adults with post-lingual deafness, the high progress of speech recovery is observed during the first year after cochlear implantation, but there is a large range of variability in the level of cochlear implant outcomes and the temporal evolution of recovery. It has been proposed that when profoundly deaf subjects receive a cochlear implant, the visual cross-modal reorganization of the brain is deleterious for auditory speech recovery. We tested this hypothesis in post-lingually deaf adults by analysing whether brain activity shortly after implantation correlated with the level of auditory recovery 6 months later. Based on brain activity induced by a speech-processing task, we found strong positive correlations in areas outside the auditory cortex. The highest positive correlations were found in the occipital cortex involved in visual processing, as well as in the posterior-temporal cortex known for audio-visual integration. The other area, which positively correlated with auditory speech recovery, was localized in the left inferior frontal area known for speech processing. Our results demonstrate that the visual modality's functional level is related to the proficiency level of auditory recovery. Based on the positive correlation of visual activity with auditory speech recovery, we suggest that visual modality may facilitate the perception of the word's auditory counterpart in communicative situations. The link demonstrated between visual activity and auditory speech perception indicates that visuoauditory synergy is crucial for cross-modal plasticity and fostering speech-comprehension recovery in adult cochlear-implanted deaf patients.

  13. Cochlear implanted pupils in Scottish schools: 4-year school attainment data (2000-2004).

    PubMed

    Thoutenhoofd, Ernst

    2006-01-01

    The Achievements of Deaf Pupils in Scotland (ADPS) project has been tracking the educational attainment of deaf pupils in Scotland's schools since 2000. At the time of writing, the database contains records for 1,752 deaf pupils (2000-2005). Here 4-year aggregate educational attainment data are reported for a subset of 152 school-aged deaf pupils with cochlear implants notified to the ADPS database between June 2000 and June 2004. The data describe primary and secondary school results in reading, writing, and math for this subgroup, as well as placement and communication characteristics. The educational attainment of the group of deaf pupils with cochlear implants is clearly marked when the deaf pupil population is disaggregated for hearing loss, achieving comparatively higher average attainment in both 5-14 Curriculum National Tests (Mathematics in particular) and Standard Grades. Therefore the gap in performance relative to the national population data is reduced for those deaf pupils, although it still widens at higher levels of achievement for the National Tests. Although most pupils with cochlear implants are placed in the mainstream, there is no pattern of migration toward mainstream schools. Some deaf pupils with cochlear implants moved out of mainstream to other types of placement, and this has implications for health-economic cost-utility assessments of cochlear implantation that favor mainstream education by drawing upon the relative cost of different placement types. These findings suggest that the ADPS program of research can contribute school outcome data as valuable real-life outcome measures in wider assessments of the benefit of cochlear implants to deaf children and deaf young people.

  14. The Role of Organ of Corti Mass in Passive Cochlear Tuning

    PubMed Central

    de La Rochefoucauld, Ombeline; Olson, Elizabeth S.

    2007-01-01

    The mechanism for passive cochlear tuning remains unsettled. Early models considered the organ of Corti complex (OCC) as a succession of spring-mass resonators. Later, traveling wave models showed that passive tuning could arise through the interaction of cochlear fluid mass and OCC stiffness without local resonators. However, including enough OCC mass to produce local resonance enhanced the tuning by slowing and thereby growing the traveling wave as it approached its resonant segment. To decide whether the OCC mass plays a role in tuning, the frequency variation of the wavenumber of the cochlear traveling wave was measured (in vivo, passive cochleae) and compared to theoretical predictions. The experimental wavenumber was found by taking the phase difference of basilar membrane motion between two longitudinally spaced locations and dividing by the distance between them. The theoretical wavenumber was a solution of the dispersion relation of a three-dimensional cochlear model with OCC mass and stiffness as the free parameters. The experimental data were only well fit by a model that included OCC mass. However, as the measurement position moved from a best-frequency place of 40 to 12 kHz, the role of mass was diminished. The notion of local resonance seems to only apply in the very high-frequency region of the cochlea. PMID:17905841

  15. Productivity of lexical categories in French-speaking children with cochlear implants.

    PubMed

    Le Normand, M-T; Ouellet, C; Cohen, H

    2003-11-01

    The productivity of lexical categories was studied longitudinally in a sample of 17 young hearing-impaired French-speaking children with cochlear implants. Age of implantation ranged from 22 months to 76 months. Spontaneous speech samples were collected at six-month intervals over a period of 36 months, starting at the one-word stage. Four general measures of their linguistic production (number of utterances, verbal fluency, vocabulary, and grammatical production) as well as 36 specific lexical categories, according to the CHILDES codes, were computed in terms of tokens, i.e., total number of words. Cochlear-implanted children (CI) were compared to a French database of normally hearing children aged 2-4 compiled by the first author. Follow-up results indicate that, at the two-year post-implantation follow-up, noun, and verb morphology was significantly impaired. At the three-year follow-up, the cochlear-implanted group had recovered on adjectives, determiners and nouns, main verbs, and auxiliaries. The two groups differed significantly in processing locative adverbs, prepositions, pronouns, and verbs (infinitive verb, modal, and modal lexical), but individual variability within the cochlear-implanted group was substantial. Results are discussed in terms of recovery and developmental trends and variability in the acquisition of lexical categories by French children two years and three years post-implantation.

  16. Evidence-based guidelines for recommending cochlear implantation for postlingually deafened adults.

    PubMed

    Leigh, Jaime R; Moran, Michelle; Hollow, Rodney; Dowell, Richard C

    2016-01-01

    Adult selection criteria for cochlear implantation have been developed based on analysis of the post-operative performance of a large group of postlingually deafened adults. Original criteria published in 2004 were reviewed and amended to reflect outcomes currently being achieved by implant recipients. Retrospective review of 12-month post-operative speech perception performance of adults implanted at the Eye and Ear Hospital, Melbourne, Australia. A total of 382 postlingually deafened adults, using a Freedom, Nucleus 5, or CI422 Slim Straight cochlear implant were used to create a comparative set of data. Revised guidelines suggest that adults with postlingual hearing loss can now be considered cochlear implant candidates if they obtain scores of up to 55% for open-set phonemes in quiet in the ear to be implanted. Functional benefit may vary depending on the recipients' contralateral hearing. This study supports the provision of cochlear implants to candidates with significant residual hearing when at least one ear meets the criterion outlined above. Patient-specific counseling is required to ensure the potential to benefit predicted by the current model is acceptable to the individual patient and their family. Counseling regarding functional benefit must take into consideration hearing in the contralateral ear.

  17. Development of micro-electromechanical system (MEMS) cochlear biomodel

    NASA Astrophysics Data System (ADS)

    Ngelayang, Thailis Bounya Anak; Latif, Rhonira

    2015-05-01

    Human cochlear is undeniably one of the most amazing organs in human body. The functional mechanism is very unique in terms of its ability to convert the sound waves in the form of mechanical vibrations into the electrical nerve impulses. It is known that the normal human auditory system can perceive the audible frequency range between 20 Hz to 20 kHz. Scientists have conducted several researches trying to build the artificial basilar membrane in the human cochlea (cochlear biomodel). Micro-electromechanical system (MEMS) is one of the potential inventions that have the ability to mimic the active behavior of the basilar membrane. In this paper, an array of MEMS bridge beams that are mechanically sensitive to the perceived audible frequency has been proposed. An array of bridge bridge beams with 0.5 µm thickness and length varying from 200 µm to 2000 µm have been designed operate within the audible frequency range. In the bridge beams design, aluminium (Al), copper (Cu), tantalum (Ta) and platinum (Pt) have considered as the material for the bridge beam structure. From the finite element (FE) and lumped element (LE) models of the MEMS bridge beams, platinum has been found to be the best material for the cochlear biomodel design, closely mimicking the basilar membrane.

  18. Cochlear implantation in patient with Dandy-walker syndrome.

    PubMed

    de Oliveira, Adriana Kosma Pires; Hamerschmidt, Rogerio; Mocelin, Marcos; Rezende, Rodrigo K

    2012-07-01

     Dandy Walker Syndrome is a congenital abnormality in the central nervous system, characterized by a deficiency in the development of middle cerebelar structures, cystic dilatation of the posterior pit communicating with the fourth ventricle and upward shift of the transverse sinuses, tentorium and dyes. Among the clinical signs are occipital protuberances, a progressive increase of the skull, bowing before the fontanels, papilledema, ataxia, gait disturbances, nystagmus, and intellectual impairment.  To describe a case of female patient, 13 years old with a diagnosis of this syndrome and bilateral hearing loss underwent cochlear implant surgery under local anesthesia and sedation.  CGS, 13 years old female was referred to the Otolaryngological Department of Otolaryngology Institute of Parana with a diagnosis of "Dandy-Walker syndrome" for Otolaryngological evaluation for bilateral hearing loss with no response to the use of hearing aids. Final Comments: The field of cochlear implants is growing rapidly. We believe that the presence of Dandy-Walker syndrome cannot be considered a contraindication to the performance of cochlear implant surgery, and there were no surgical complications due to neurological disorders with very favorable results for the patient who exhibits excellent discrimination. It has less need for lip reading with improvement in speech quality.

  19. High-frequency hearing impairment assessed with cochlear microphonics.

    PubMed

    Zhang, Ming

    2012-09-01

    Cochlear microphonic (CM) measurements may potentially become a supplementary approach to otoacoustic emission (OAE) measurements for assessing low-frequency cochlear functions in the clinic. The objective of this study was to investigate the measurement of CMs in subjects with high-frequency hearing loss. Currently, CMs can be measured using electrocochleography (ECochG or ECoG) techniques. Both CMs and OAEs are cochlear responses, while auditory brainstem responses (ABRs) are not. However, there are inherent limitations associated with OAE measurements such as acoustic noise, which can conceal low-frequency OAEs measured in the clinic. However, CM measurements may not have these limitations. CMs were measured in human subjects using an ear canal electrode. The CMs were compared between the high-frequency hearing loss group and the normal-hearing control group. Distortion product OAEs (DPOAEs) and audiogram were also measured. The DPOAE and audiogram measurements indicate that the subjects were correctly selected for the two groups. Low-frequency CM waveforms (CMWs) can be measured using ear canal electrodes in high-frequency hearing loss subjects. The difference in amplitudes of CMWs between the high-frequency hearing loss group and the normal-hearing group is insignificant at low frequencies but significant at high frequencies.

  20. Cochlear implantation in patient with Dandy-walker syndrome

    PubMed Central

    de Oliveira, Adriana Kosma Pires; Hamerschmidt, Rogerio; Mocelin, Marcos; Rezende, Rodrigo K.

    2012-01-01

    Summary Introduction: Dandy Walker Syndrome is a congenital abnormality in the central nervous system, characterized by a deficiency in the development of middle cerebelar structures, cystic dilatation of the posterior pit communicating with the fourth ventricle and upward shift of the transverse sinuses, tentorium and dyes. Among the clinical signs are occipital protuberances, a progressive increase of the skull, bowing before the fontanels, papilledema, ataxia, gait disturbances, nystagmus, and intellectual impairment. Objectives: To describe a case of female patient, 13 years old with a diagnosis of this syndrome and bilateral hearing loss underwent cochlear implant surgery under local anesthesia and sedation. Case Report: CGS, 13 years old female was referred to the Otolaryngological Department of Otolaryngology Institute of Parana with a diagnosis of “Dandy-Walker syndrome” for Otolaryngological evaluation for bilateral hearing loss with no response to the use of hearing aids. Final Comments: The field of cochlear implants is growing rapidly. We believe that the presence of Dandy-Walker syndrome cannot be considered a contraindication to the performance of cochlear implant surgery, and there were no surgical complications due to neurological disorders with very favorable results for the patient who exhibits excellent discrimination. It has less need for lip reading with improvement in speech quality. PMID:25991966

  1. Intraoperative seizure and cerebrospinal fluid leak during adult cochlear implant surgery.

    PubMed

    Musser, Alexander B; Golub, Justin S; Samy, Ravi N; Phero, James C

    2016-01-01

    To report a rare case of cerebrospinal fluid gusher and subsequent seizure immediately after cochlear implant electrode insertion. After the cochlear implant electrode was inserted, brisk flow of 10 mL of cerebrospinal fluid was seen. The electrode was promptly inserted and the leak was additionally sealed with fascia. Seconds later, the patient had a tonic-clonic seizure lasting 30 seconds. Two additional episodes occurred during the case. Her postoperative course was uneventful with no subsequent seizures. The device has been successfully activated. Intervention & Technique: Postoperative imaging showed correct intracochlear placement of the electrode as well as an incidental enlarged vestibular aqueduct. Neurology consultation including electroencephalogram was unremarkable. To our knowledge, this is the first report of a seizure temporally associated with cochlear implant electrode insertion. The significance and possible casual relationship between these two events is discussed.

  2. Persistent Language Delay versus Late Language Emergence in Children with Early Cochlear Implantation

    ERIC Educational Resources Information Center

    Geers, Ann E.; Nicholas, Johanna; Tobey, Emily; Davidson, Lisa

    2016-01-01

    Purpose: The purpose of the present investigation is to differentiate children using cochlear implants (CIs) who did or did not achieve age-appropriate language scores by mid-elementary grades and to identify risk factors for persistent language delay following early cochlear implantation. Materials and Method: Children receiving unilateral CIs at…

  3. Relationship between auditory perception and vocal production in cochlear implantees: a systematic review.

    PubMed

    Cysneiros, Helena Renata Silva; Leal, Mariana de Carvalho; Lucena, Jonia Alves; Muniz, Lilian Ferreira

    To conduct a systematic review of the scientific literature studying the relationship between vocal production and auditory perception in cochlear implant users. This is an integrative systematic review. The plattforms/databases Bireme, SciELO, Cochrane, Scopus and Web of Science were consulted and the descriptors used were voice, cochlear implant and auditory perception. Original papers published in English, French, Spanish or Portuguese involving the study of vocal production and auditory perception in cochlear implant users were selected and there was no restriction about year of publication of the articles. The studies selected were analyzed according to the author, location, year and publication of the article, as well as for their sample size, type of vocal production and auditory perception assessment and for its major findings and recommendation grade/level of scientific evidence. The results suggest the existence of positive relationship between vocal production and auditory perception in cochlear implant users, and indicate that the deployment time has a positive influence in this relationship. None of the selected studies were rated at level 1 of scientific evidence or grade A of recommendation, which is related to the methodological approach that can go with this subject matter. There is great lack of publications relating auditory perception and speech production in cochlear implant users. This gap is even greater when it comes to the adult population.

  4. Feed-forward and feed-backward amplification model from cochlear cytoarchitecture: an interspecies comparison.

    PubMed

    Yoon, Yong-Jin; Steele, Charles R; Puria, Sunil

    2011-01-05

    The high sensitivity and wide bandwidth of mammalian hearing are thought to derive from an active process involving the somatic and hair-bundle motility of the thousands of outer hair cells uniquely found in mammalian cochleae. To better understand this, a biophysical three-dimensional cochlear fluid model was developed for gerbil, chinchilla, cat, and human, featuring an active "push-pull" cochlear amplifier mechanism based on the cytoarchitecture of the organ of Corti and using the time-averaged Lagrangian method. Cochlear responses are simulated and compared with in vivo physiological measurements for the basilar membrane (BM) velocity, V(BM), frequency tuning of the BM vibration, and Q₁₀ values representing the sharpness of the cochlear tuning curves. The V(BM) simulation results for gerbil and chinchilla are consistent with in vivo cochlea measurements. Simulated mechanical tuning curves based on maintaining a constant V(BM) value agree with neural-tuning threshold measurements better than those based on a constant displacement value, which implies that the inner hair cells are more sensitive to V(BM) than to BM displacement. The Q₁₀ values of the V(BM) tuning curve agree well with those of cochlear neurons across species, and appear to be related in part to the width of the basilar membrane. Copyright © 2011 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  5. Evaluation on health-related quality of life in deaf children with cochlear implant in China.

    PubMed

    Liu, Hong; Liu, Hong-Xiang; Kang, Hou-Yong; Gu, Zheng; Hong, Su-Ling

    2016-09-01

    Previous studies have shown that deaf children benefit considerably from cochlear implants. These improvements are found in areas such as speech perception, speech production, and audiology-verbal performance. Despite the increasing prevalence of cochlear implants in China, few studies have reported on health-related quality of life in children with cochlear implants. The main objective of this study was to explore health-related quality of life on children with cochlear implants in South-west China. A retrospective observational study of 213 CI users in Southwest China between 2010 and 2013. Participants were 213 individuals with bilateral severe-to-profound hearing loss who wore unilateral cochlear implants. The Nijmegen Cochlear Implant Questionnaire and Health Utility Index Mark III were used pre-implantation and 1 year post-implantation. Additionally, 1-year postoperative scores for Mandarin speech perception were compared with preoperative scores. Health-related quality of life improved post-operation with scores on the Nijmegen Cochlear Implant Questionnaire improving significantly in all subdomains, and the Health Utility Index 3 showing a significant improvement in the utility score and the subdomains of ''hearing," ''speech," and "emotion". Additionally, a significant improvement in speech recognition scores was found. No significant correlation was found between increased in quality of life and speech perception scores. Health-related quality of life and speech recognition in prelingual deaf children significantly improved post-operation. The lack of correlation between quality of life and speech perception suggests that when evaluating performance post-implantation in prelingual deaf children and adolescents, measures of both speech perception and quality of life should be used. Copyright © 2016. Published by Elsevier Ireland Ltd.

  6. Fibro-vascular coupling in the control of cochlear blood flow.

    PubMed

    Dai, Min; Shi, Xiaorui

    2011-01-01

    Transduction of sound in the cochlea is metabolically demanding. The lateral wall and hair cells are critically vulnerable to hypoxia, especially at high sound levels, and tight control over cochlear blood flow (CBF) is a physiological necessity. Yet despite the importance of CBF for hearing, consensus on what mechanisms are involved has not been obtained. We report on a local control mechanism for regulating inner ear blood flow involving fibrocyte signaling. Fibrocytes in the super-strial region are spatially distributed near pre-capillaries of the spiral ligament of the albino guinea pig cochlear lateral wall, as demonstrably shown in transmission electron microscope and confocal images. Immunohistochemical techniques reveal the inter-connected fibrocytes to be positive for Na+/K+ ATPase β1 and S100. The connected fibrocytes display more Ca(2+) signaling than other cells in the cochlear lateral wall as indicated by fluorescence of a Ca(2+) sensor, fluo-4. Elevation of Ca(2+) in fibrocytes, induced by photolytic uncaging of the divalent ion chelator o-nitrophenyl EGTA, results in propagation of a Ca(2+) signal to neighboring vascular cells and vasodilation in capillaries. Of more physiological significance, fibrocyte to vascular cell coupled signaling was found to mediate the sound stimulated increase in cochlear blood flow (CBF). Cyclooxygenase-1 (COX-1) was required for capillary dilation. The findings provide the first evidence that signaling between fibrocytes and vascular cells modulates CBF and is a key mechanism for meeting the cellular metabolic demand of increased sound activity.

  7. Changes in Speech Production in an Early Deafened Adult with a Cochlear Implant

    ERIC Educational Resources Information Center

    Wong, Patrick C. M.

    2007-01-01

    Background and Aims: The current study is a first investigation reporting the speech production characteristics of an early deafened adult cochlear implant user after a course of speech-language treatment. Methods and Procedures: The participant is culturally deaf and received the cochlear implant when she was 43 years old. A 24-week ABCABC…

  8. Suppression tuning of distortion-product otoacoustic emissions: Results from cochlear mechanics simulation

    PubMed Central

    Liu, Yi-Wen; Neely, Stephen T.

    2013-01-01

    This paper presents the results of simulating the acoustic suppression of distortion-product otoacoustic emissions (DPOAEs) from a computer model of cochlear mechanics. A tone suppressor was introduced, causing the DPOAE level to decrease, and the decrement was plotted against an increasing suppressor level. Suppression threshold was estimated from the resulting suppression growth functions (SGFs), and suppression tuning curves (STCs) were obtained by plotting the suppression threshold as a function of suppressor frequency. Results show that the slope of SGFs is generally higher for low-frequency suppressors than high-frequency suppressors, resembling those obtained from normal hearing human ears. By comparing responses of normal (100%) vs reduced (50%) outer-hair-cell sensitivities, the model predicts that the tip-to-tail difference of the STCs correlates well with that of intra-cochlear iso-displacement tuning curves. The correlation is poorer, however, between the sharpness of the STCs and that of the intra-cochlear tuning curves. These results agree qualitatively with what was recently reported from normal-hearing and hearing-impaired human subjects, and examination of intra-cochlear model responses can provide the needed insight regarding the interpretation of DPOAE STCs obtained in individual ears. PMID:23363112

  9. A comparison of speech intonation production and perception abilities of Farsi speaking cochlear implanted and normal hearing children.

    PubMed

    Moein, Narges; Khoddami, Seyyedeh Maryam; Shahbodaghi, Mohammad Rahim

    2017-10-01

    Cochlear implant prosthesis facilitates spoken language development and speech comprehension in children with severe-profound hearing loss. However, this prosthesis is limited in encoding information about fundamental frequency and pitch that are essentially for recognition of speech prosody. The purpose of the present study is to investigate the perception and production of intonation in cochlear implant children and comparison with normal hearing children. This study carried out on 25 cochlear implanted children and 50 children with normal hearing. First, using 10 action pictures statements and questions sentences were extracted. Fundamental frequency and pitch changes were identified using Praat software. Then, these sentences were judged by 7 adult listeners. In second stage 20 sentences were played for child and he/she determined whether it was in a question form or statement one. Performance of cochlear implanted children in perception and production of intonation was significantly lower than children with normal hearing. The difference between fundamental frequency and pitch changes in cochlear implanted children and children with normal hearing was significant (P < 0/05). Cochlear implanted children performance in perception and production of intonation has significant correlation with child's age surgery and duration of prosthesis use (P < 0/05). The findings of the current study show that cochlear prostheses have limited application in facilitating the perception and production of intonation in cochlear implanted children. It should be noted that the child's age at the surgery and duration of prosthesis's use is important in reduction of this limitation. According to these findings, speech and language pathologists should consider intervention of intonation in treatment program of cochlear implanted children. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Ozone Prevents Cochlear Damage From Ischemia-Reperfusion Injury in Guinea Pigs.

    PubMed

    Onal, Merih; Elsurer, Cagdas; Selimoglu, Nebil; Yilmaz, Mustafa; Erdogan, Ender; Bengi Celik, Jale; Kal, Oznur; Onal, Ozkan

    2017-08-01

    The cochlea is an end organ, which is metabolically dependent on a nutrient and oxygen supply to maintain its normal physiological function. Cochlear ischemia and reperfusion (IR) injury is considered one of the most important causes of human idiopathic sudden sensorineural hearing loss. The aim of the present study was to study the efficacy of ozone therapy against cochlear damage caused by IR injury and to investigate the potential clinical use of this treatment for sudden deafness. Twenty-eight guinea pigs were randomized into four groups. The sham group (S) (n = 7) was administered physiological saline intraperitoneally (i.p.) for 7 days. The ozone group (O) (n = 7) was administered 1 mg/kg of ozone i.p. for 7 days. In the IR + O group (n = 7), 1 mg/kg of ozone was administered i.p. for 7 days before IR injury. On the eighth day, the IR + O group was subjected to cochlear ischemia for 15 min by occluding the bilateral vertebral artery and vein with a nontraumatic clamp and then reperfusion for 2 h. The IR group was subjected to cochlear IR injury. After the IR procedure, the guinea pigs were sacrificed on the same day. In a general histological evaluation, cochlear and spiral ganglionic tissues were examined with a light microscope, and apoptotic cells were counted by terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL) staining. The apoptotic index (AI) was then calculated. Blood samples were sent for analyses of superoxide dismutase (SOD), glutathione peroxidase (GSH-Px), catalase, malondialdehyde (MDA), the total oxidant score (TOS), and total antioxidant capacity (TAC). Data were evaluated statistically using the Kruskal-Wallis test. The AI was highest in the IR group. The AI of the IR + O group was lower than that of the IR group. The biochemical antioxidant parameters SOD and GSH-Px and the TAC values were highest in the O group and lowest in the IR group. The MDA level and TOS were highest in the IR group and lowest

  11. Cochlear implant: the family's perspective.

    PubMed

    Vieira, Sheila de Souza; Dupas, Giselle; Chiari, Brasilia Maria

    2018-07-01

    To understand the family's experience of a child who uses a cochlear implant (CI). Specifically, to identify the difficulties, changes, and feelings entailed by deafness and the use of the CI; the coping strategies; and to understand the role of the family for the child with a CI. Qualitative research, using Symbolic Interactionism and Straussian Grounded Theory as the theoretical and methodological frameworks, respectively. Data collection instrument: semi-structured interview. A total of 9 families (32 individuals) participated in the study. The children's ages ranged from 6 to 11 years old (mean = 8.9 years old). Their experience is described in the following categories: Having to fight for results, Coping with difficult situations, Recognizing that you are not alone, Learning to overcome, and Having one's life restored by the implant. Cochlear implantation changes the direction of the child and the family's life by restoring the child's opportunity to hear and to obtain good results in her personal, social, and academic development. Even after implantation, the child continues to experience difficulties and requires the family's mobilization in order to be successful. The family is the principal actor in the process of the child's rehabilitation.

  12. Dislocation of cochlear implant magnet as a complication following MRI.

    PubMed

    Murtojärvi, Sarita; Salonen, Jaakko

    According to current best knowledge, an MRI scan can be performed for patients with cochlear implants. The warnings and recommendations of the implant manufacturers must be followed strictly to prevent complications, such as overheating, migration or demagnetization of the magnet in the implant. We report on a case of cochlear implant magnet dislocation as a complication for an MRI scan. The patient had a tight bandage around the head to hold the magnet in place as recommended by the manufacturer, but apparently the bandage was not in the correct place.

  13. Continued Expression of GATA3 Is Necessary for Cochlear Neurosensory Development

    PubMed Central

    Duncan, Jeremy S.; Fritzsch, Bernd

    2013-01-01

    Hair cells of the developing mammalian inner ear are progressively defined through cell fate restriction. This process culminates in the expression of the bHLH transcription factor Atoh1, which is necessary for differentiation of hair cells, but not for their specification. Loss of several genes will disrupt ear morphogenesis or arrest of neurosensory epithelia development. We previously showed in null mutants that the loss of the transcription factor, Gata3, results specifically in the loss of all cochlear neurosensory development. Temporal expression of Gata3 is broad from the otic placode stage through the postnatal ear. It therefore remains unclear at which stage in development Gata3 exerts its effect. To better understand the stage specific effects of Gata3, we investigated the role of Gata3 in cochlear neurosensory specification and differentiation utilizing a LoxP targeted Gata3 line and two Cre lines. Foxg1Cre∶Gata3f/f mice show recombination of Gata3 around E8.5 but continue to develop a cochlear duct without differentiated hair cells and spiral ganglion neurons. qRT-PCR data show that Atoh1 was down-regulated but not absent in the duct whereas other hair cell specific genes such as Pou4f3 were completely absent. In addition, while Sox2 levels were lower in the Foxg1Cre:Gata3f/f cochlea, Eya1 levels remained normal. We conclude that Eya1 is unable to fully upregulate Atoh1 or Pou4f3, and drive differentiation of hair cells without Gata3. Pax2-Cre∶Gata3f/f mice show a delayed recombination of Gata3 in the ear relative to Foxg1Cre:Gata3f/f. These mice exhibited a cochlear duct containing patches of partially differentiated hair cells and developed only few and incorrectly projecting spiral ganglion neurons. Our conditional deletion studies reveal a major role of Gata3 in the signaling of prosensory genes and in the differentiation of cochlear neurosenory cells. We suggest that Gata3 may act in combination with Eya1, Six1, and Sox2 in cochlear prosensory

  14. Exploring views on current and future cochlear implant service delivery: the perspectives of users, parents and professionals at cochlear implant centres and in the community.

    PubMed

    Athalye, Sheetal; Archbold, Sue; Mulla, Imran; Lutman, Mark; Nikolopoulous, Thomas

    2015-09-01

    The objective of this survey was to explore the perceptions of implant users/carers and professionals across the UK about current and future cochlear implant service delivery and the challenges. Data were collected via an online questionnaire consisting of totally 22 questions. The questionnaire contained both open- and close-ended questions. Totally, seven hundred and forty-eight responses were received. In spite of the wide range of respondents, there was a broad consensus of opinion across groups. The majority of participants were satisfied with the service they currently receive, but wanted some changes. They reported their current experience of implant services to be mainly driven by decisions made by the implant team. For the future, they preferred the service to be mainly driven by decisions made jointly by the team and the user and/or parent/carer. The majority of participants wanted the cochlear implant services to be integrated into local audiology and other services such as education. Restrictions on number of candidates funded and political decisions and issues were seen as major challenges. Qualitative analysis of the open-ended responses supported the questionnaire responses. This research highlighted the benefits and limitations of the current cochlear implant service delivery as well as the potential implications for the long term. While respondents were generally happy with the current cochlear implant service provision, they expressed some concerns about the long-term sustainability and management, wanting integration into the local services, and more involvement of parents and users in decisions.

  15. Optoacoustic effect is responsible for laser-induced cochlear responses

    NASA Astrophysics Data System (ADS)

    Kallweit, N.; Baumhoff, P.; Krueger, A.; Tinne, N.; Kral, A.; Ripken, T.; Maier, H.

    2016-06-01

    Optical stimulation of the cochlea with laser light has been suggested as an alternative to conventional treatment of sensorineural hearing loss with cochlear implants. The underlying mechanisms are controversially discussed: The stimulation can either be based on a direct excitation of neurons, or it is a result of an optoacoustic pressure wave acting on the basilar membrane. Animal studies comparing the intra-cochlear optical stimulation of hearing and deafened guinea pigs have indicated that the stimulation requires intact hair cells. Therefore, optoacoustic stimulation seems to be the underlying mechanism. The present study investigates optoacoustic characteristics using pulsed laser stimulation for in vivo experiments on hearing guinea pigs and pressure measurements in water. As a result, in vivo as well as pressure measurements showed corresponding signal shapes. The amplitude of the signal for both measurements depended on the absorption coefficient and on the maximum of the first time-derivative of laser pulse power (velocity of heat deposition). In conclusion, the pressure measurements directly demonstrated that laser light generates acoustic waves, with amplitudes suitable for stimulating the (partially) intact cochlea. These findings corroborate optoacoustic as the basic mechanism of optical intra-cochlear stimulation.

  16. Voice gender identification by cochlear implant users: The role of spectral and temporal resolution

    NASA Astrophysics Data System (ADS)

    Fu, Qian-Jie; Chinchilla, Sherol; Nogaki, Geraldine; Galvin, John J.

    2005-09-01

    The present study explored the relative contributions of spectral and temporal information to voice gender identification by cochlear implant users and normal-hearing subjects. Cochlear implant listeners were tested using their everyday speech processors, while normal-hearing subjects were tested under speech processing conditions that simulated various degrees of spectral resolution, temporal resolution, and spectral mismatch. Voice gender identification was tested for two talker sets. In Talker Set 1, the mean fundamental frequency values of the male and female talkers differed by 100 Hz while in Talker Set 2, the mean values differed by 10 Hz. Cochlear implant listeners achieved higher levels of performance with Talker Set 1, while performance was significantly reduced for Talker Set 2. For normal-hearing listeners, performance was significantly affected by the spectral resolution, for both Talker Sets. With matched speech, temporal cues contributed to voice gender identification only for Talker Set 1 while spectral mismatch significantly reduced performance for both Talker Sets. The performance of cochlear implant listeners was similar to that of normal-hearing subjects listening to 4-8 spectral channels. The results suggest that, because of the reduced spectral resolution, cochlear implant patients may attend strongly to periodicity cues to distinguish voice gender.

  17. Comparison of auditory comprehension skills in children with cochlear implant and typically developing children.

    PubMed

    Mandal, Joyanta Chandra; Kumar, Suman; Roy, Sumit

    2016-12-01

    The main goal of this study was to obtain auditory comprehension skills of native Hindi speaking children with cochlear implant and typically developing children across the age of 3-7 years and compare the scores between two groups. A total of sixty Hindi speaking participants were selected for the study. They were divided into two groups- Group-A consisted of thirty children with normal hearing and Group-B thirty children using cochlear implants. To assess the auditory comprehension skills, Test of auditory comprehension in Hindi (TACH) was used. The participant was required to point to one of three pictures which would best correspond to the stimulus presented. Correct answers were scored as 1 and incorrect answers as 0. TACH was administered on for both groups. Independent t-test was applied and it was found that auditory comprehension scores of children using cochlear implant were significantly poorer than the score of children with normal hearing for all three subtests. Pearson's correlation coefficient revealed poor correlation between the scores of children with normal hearing and children using cochlear implant. The results of this study suggest that children using cochlear implant have poor auditory comprehension skills than children with normal hearing. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  18. The effect of superior canal dehiscence on cochlear potential in response to air-conducted stimuli in chinchilla

    PubMed Central

    Songer, Jocelyn E.; Rosowski, John J.

    2006-01-01

    A superior semicircular canal dehiscence (SCD) is a break or hole in the bony wall of the superior semicircular canal. Patients with SCD syndrome present with a variety of symptoms: some with vestibular symptoms, others with auditory symptoms (including low-frequency conductive hearing loss) and yet others with both. We are interested in whether or not mechanically altering the superior canal by introducing a dehiscence is sufficient to cause the low-frequency conductive hearing loss associated with SCD syndrome. We evaluated the effect of a surgically introduced dehiscence on auditory responses to air-conducted (AC) stimuli in 11 chinchilla ears. Cochlear potential (CP) was recorded at the round-window before and after a dehiscence was introduced. In each ear, a decrease in CP in response to low frequency (<2 kHz) sound stimuli was observed after the introduction of the dehiscence. The dehiscence was then patched with cyanoacrylate glue leading to a reversal of the dehiscence-induced changes in CP. The reversible decrease in auditory sensitivity observed in chinchilla is consistent with the elevated AC thresholds observed in patients with SCD. According to the ‘third-window’ hypothesis the SCD shunts sound-induced stapes velocity away from the cochlea, resulting in decreased auditory sensitivity to AC sounds. The data collected in this study are consistent with predictions of this hypothesis. PMID:16150562

  19. Language, Mental State Vocabulary, and False Belief Understanding in Children with Cochlear Implants

    ERIC Educational Resources Information Center

    Peters, Kimberly; Remmel, Ethan; Richards, Debra

    2009-01-01

    Purpose: This study examined false belief understanding and its predictors in school-age children who are deaf with cochlear implants and who use spoken language. Method: False belief understanding was measured through an explanation-of-action task in 30 children between the ages of 3 and 12 years who used cochlear implants. Children told a…

  20. The Self-Regulation of a Child with Cochlear Implants within a School Environment

    ERIC Educational Resources Information Center

    Patton, Kristin L.

    2013-01-01

    The purpose of this qualitative research, which utilized a narrative design strategy, was to describe the process of self-regulation of a child who has bilateral cochlear implants within the social environment of school. The study investigated the use of self-regulatory strategies by the cochlear implant recipient. It also examined how the child…

  1. American parent perspectives on quality of life in pediatric cochlear implant recipients.

    PubMed

    Kumar, Roshini; Warner-Czyz, Andrea; Silver, Cheryl H; Loy, Betty; Tobey, Emily

    2015-01-01

    Cochlear implantation influences not only communication but also psychosocial outcomes in children with severe to profound hearing loss. Focusing on issues specific to cochlear implantation (e.g., self-reliance, social relations, education, effects of implantation, and supporting the child) may provide a more accurate and relative view of functional status of pediatric cochlear implant (CI) recipients. The present study analyzes parental perspectives of CI-specific health-related quality of life (HRQoL) in children with CIs to determine (a) if parents differentially rate their child's quality of life according to psychosocial domain (e.g., communication, self-reliance, education); (b) if associations exist between quality of life domains specific to cochlear implantation in pediatric implant recipients; and (c) if demographic variables (i.e., chronologic age, age at cochlear implantation, duration of device experience) mediate parent ratings of quality of life in pediatric CI recipients. Parents of 33 children with CIs (mean age, 9.85 years; mean age of CI activation, 2.47 years; mean device experience, 7.47 years) completed a validated condition-specific questionnaire, Children With Cochlear Implants: Parental Perspectives. Parents positively rated most HRQoL domains, although education and effects of implantation received significantly less positive ratings (p < 0.01). Three domains (communication, self-reliance, and well-being) significantly correlated with at least 5 other domains, suggesting that positivity in one domain co-occurs with positivity in other domains. Demographic variables (chronologic age, CI activation age, and duration of CI use) did not correlate significantly with psychosocial outcomes; rather, parents reported positive HRQoL and successful functional use of CI across demographic variables. Parents of children and adolescents with CIs rate overall HRQoL positively across psychosocial domains. Significantly less positive ratings of education

  2. The mammalian bony labyrinth reconsidered, introducing a comprehensive geometric morphometric approach

    PubMed Central

    Gunz, Philipp; Ramsier, Marissa; Kuhrig, Melanie; Hublin, Jean-Jacques; Spoor, Fred

    2012-01-01

    The bony labyrinth in the temporal bone houses the sensory systems of balance and hearing. While the overall structure of the semicircular canals and cochlea is similar across therian mammals, their detailed morphology varies even among closely related groups. As such, the shape of the labyrinth carries valuable functional and phylogenetic information. Here we introduce a new, semilandmark-based three-dimensional geometric morphometric approach to shape analysis of the labyrinth, as a major improvement upon previous metric studies based on linear measurements and angles. We first provide a detailed, step-by-step description of the measurement protocol. Subsequently, we test our approach using a geographically diverse sample of 50 recent modern humans and 30 chimpanzee specimens belonging to Pan troglodytes troglodytes and P. t. verus. Our measurement protocol can be applied to CT scans of different spatial resolutions because it primarily quantifies the midline skeleton of the bony labyrinth. Accurately locating the lumen centre of the semicircular canals and the cochlea is not affected by the partial volume and thresholding effects that can make the comparison of the outer border problematic. After virtually extracting the bony labyrinth from CT scans of the temporal bone, we computed its midline skeleton by thinning the encased volume. On the resulting medial axes of the semicircular canals and cochlea we placed a sequence of semilandmarks. After Procrustes superimposition, the shape coordinates were analysed using multivariate statistics. We found statistically significant shape differences between humans and chimpanzees which corroborate previous analyses of the labyrinth based on traditional measurements. As the geometric relationship among the semilandmark coordinates was preserved throughout the analysis, we were able to quantify and visualize even small-scale shape differences. Notably, our approach made it possible to detect and visualize subtle, yet

  3. Patients reported outcome post-cochlear implantation: how severe is their dizziness?

    PubMed

    Zawawi, Faisal; Alobaid, Faisal; Leroux, Tony; Zeitouni, Anthony G

    2014-01-01

    The reported prevalence of vestibular dysfunction after cochlear implantation (CI) is varies between different scientific papers. The aim of this study is to determine the reported post-implantation outcome in terms of dizziness, and to measure its impact on quality of life using the Dizziness handicap inventory (DHI). This was a prospective questionnaire based study of postoperative cochlear implant patients. The questionnaire assessed the type and onset of dizziness in addition to the DHI. 122 patients were recruited in this study, which is the largest sample size in the literature reported so far. Dizziness was evident in 45.9% of the population post-CI and in 27% pre-CI. The commonest subtype of the dizziness was unsteadiness followed by lightheadedness. The dizziness was mild in most of the patients. Although mild, dizziness is a common complaint post-cochlear implantation. An understanding of symptoms helps counsel patients preoperatively.

  4. Electroacoustic verification of frequency modulation systems in cochlear implant users.

    PubMed

    Fidêncio, Vanessa Luisa Destro; Jacob, Regina Tangerino de Souza; Tanamati, Liége Franzini; Bucuvic, Érika Cristina; Moret, Adriane Lima Mortari

    2017-12-26

    The frequency modulation system is a device that helps to improve speech perception in noise and is considered the most beneficial approach to improve speech recognition in noise in cochlear implant users. According to guidelines, there is a need to perform a check before fitting the frequency modulation system. Although there are recommendations regarding the behavioral tests that should be performed at the fitting of the frequency modulation system to cochlear implant users, there are no published recommendations regarding the electroacoustic test that should be performed. Perform and determine the validity of an electroacoustic verification test for frequency modulation systems coupled to different cochlear implant speech processors. The sample included 40 participants between 5 and 18 year's users of four different models of speech processors. For the electroacoustic evaluation, we used the Audioscan Verifit device with the HA-1 coupler and the listening check devices corresponding to each speech processor model. In cases where the transparency was not achieved, a modification was made in the frequency modulation gain adjustment and we used the Brazilian version of the "Phrases in Noise Test" to evaluate the speech perception in competitive noise. It was observed that there was transparency between the frequency modulation system and the cochlear implant in 85% of the participants evaluated. After adjusting the gain of the frequency modulation receiver in the other participants, the devices showed transparency when the electroacoustic verification test was repeated. It was also observed that patients demonstrated better performance in speech perception in noise after a new adjustment, that is, in these cases; the electroacoustic transparency caused behavioral transparency. The electroacoustic evaluation protocol suggested was effective in evaluation of transparency between the frequency modulation system and the cochlear implant. Performing the adjustment of

  5. [Model oriented assessment of literacy performance in children with cochlear implants].

    PubMed

    Fiori, A; Reichmuth, K; Matulat, P; Schmidt, C M; Dinnesen, A G

    2006-07-01

    Although most hearing-impaired children lag behind normally hearing children in literacy acquisition, this aspect has hardly been addressed in the evaluation of language acquisition after cochlear implantation. The present study investigated written language abilities in 8 school-age children with cochlear implants. Neurolinguistic dual-route-models of written language processing indicate that literacy acquisition leads to the establishment of two distinct reading and writing strategies: a lexical one for the quick processing of known words and a sublexical one for decoding unfamiliar words or nonwords letter by letter. 8 school-aged children were investigated, a very heterogeneous group concerning age of onset of hearing impairment, educational placement, and competences in sign language. However, this range is typical of the group of CI-children. The aim was to investigate if children with cochlear implants are able to establish both strategies or if they need to find a differential and individual access to written language. Performance within the Salzburger Lese-Rechtschreib-Test was evaluated. Individual performance of each subject was analysed. Performance varied substantially ranging from only rudimentary spoken and written language abilities in two children to age-equivalent performance in three of them. Severe qualitative differences in written language processing were shown in the remaining three subjects. Suggestions for remediation were made and a re-test was carried out after 12 months. Their individual profiles of performance are described in detail. The present study stresses the importance of a thorough investigation of written language performance in the evaluation of language acquisition after cochlear implantation. The results draw a very heterogeneous picture of performance. Model-oriented testing and analysis of performance prove to be sensible in at least a subpopulation of children with cochlear implants. Based on a better understanding of

  6. Intracochlear Scala Media Pressure Measurement: Implications for Models of Cochlear Mechanics.

    PubMed

    Kale, Sushrut S; Olson, Elizabeth S

    2015-12-15

    Models of the active cochlea build upon the underlying passive mechanics. Passive cochlear mechanics is based on physical and geometrical properties of the cochlea and the fluid-tissue interaction between the cochlear partition and the surrounding fluid. Although the fluid-tissue interaction between the basilar membrane and the fluid in scala tympani (ST) has been explored in both active and passive cochleae, there was no experimental data on the fluid-tissue interaction on the scala media (SM) side of the partition. To this aim, we measured sound-evoked intracochlear pressure in SM close to the partition using micropressure sensors. All the SM pressure data are from passive cochleae, likely because the SM cochleostomy led to loss of endocochlear potential. Thus, these experiments are studies of passive cochlear mechanics. SM pressure close to the tissue showed a pattern of peaks and notches, which could be explained as an interaction between fast and slow (i.e., traveling wave) pressure modes. In several animals SM and ST pressure were measured in the same cochlea. Similar to previous studies, ST-pressure was dominated by a slow, traveling wave mode at stimulus frequencies in the vicinity of the best frequency of the measurement location, and by a fast mode above best frequency. Antisymmetric pressure between SM and ST supported the classic single-partition cochlear models, or a dual-partition model with tight coupling between partitions. From the SM and ST pressure we calculated slow and fast modes, and from active ST pressure we extrapolated the passive findings to the active case. The passive slow mode estimated from SM and ST data was low-pass in nature, as predicted by cochlear models. Copyright © 2015 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  7. EEG frontal asymmetry related to pleasantness of music perception in healthy children and cochlear implanted users.

    PubMed

    Vecchiato, G; Maglione, A G; Scorpecci, A; Malerba, P; Marsella, P; Di Francesco, G; Vitiello, S; Colosimo, A; Babiloni, Fabio

    2012-01-01

    Interestingly, the international debate about the quality of music fruition for cochlear implanted users does not take into account the hypothesis that bilateral users could perceive music in a more pleasant way with respect to monolateral users. In this scenario, the aim of the present study was to investigate if cerebral signs of pleasantness during music perception in healthy child are similar to those observed in monolateral and in bilateral cochlear implanted users. In fact, previous observations in literature on healthy subjects have indicated that variations of the frontal EEG alpha activity are correlated with the perceived pleasantness of the sensory stimulation received (approach-withdrawal theory). In particular, here we described differences between cortical activities estimated in the alpha frequency band for a healthy child and in patients having a monolateral or a bilateral cochlear implant during the fruition of a musical cartoon. The results of the present analysis showed that the alpha EEG asymmetry patterns observed in a healthy child and that of a bilateral cochlear implanted patient are congruent with the approach-withdrawal theory. Conversely, the scalp topographic distribution of EEG power spectra in the alpha band resulting from the monolateral cochlear user presents a different EEG pattern from the normal and bilateral implanted patients. Such differences could be explained at the light of the approach-withdrawal theory. In fact, the present findings support the hypothesis that a monolateral cochlear implanted user could perceive the music in a less pleasant way when compared to a healthy subject or to a bilateral cochlear user.

  8. Degradation of labial information modifies audiovisual speech perception in cochlear-implanted children.

    PubMed

    Huyse, Aurélie; Berthommier, Frédéric; Leybaert, Jacqueline

    2013-01-01

    The aim of the present study was to examine audiovisual speech integration in cochlear-implanted children and in normally hearing children exposed to degraded auditory stimuli. Previous studies have shown that speech perception in cochlear-implanted users is biased toward the visual modality when audition and vision provide conflicting information. Our main question was whether an experimentally designed degradation of the visual speech cue would increase the importance of audition in the response pattern. The impact of auditory proficiency was also investigated. A group of 31 children with cochlear implants and a group of 31 normally hearing children matched for chronological age were recruited. All children with cochlear implants had profound congenital deafness and had used their implants for at least 2 years. Participants had to perform an /aCa/ consonant-identification task in which stimuli were presented randomly in three conditions: auditory only, visual only, and audiovisual (congruent and incongruent McGurk stimuli). In half of the experiment, the visual speech cue was normal; in the other half (visual reduction) a degraded visual signal was presented, aimed at preventing lipreading of good quality. The normally hearing children received a spectrally reduced speech signal (simulating the input delivered by the cochlear implant). First, performance in visual-only and in congruent audiovisual modalities were decreased, showing that the visual reduction technique used here was efficient at degrading lipreading. Second, in the incongruent audiovisual trials, visual reduction led to a major increase in the number of auditory based responses in both groups. Differences between proficient and nonproficient children were found in both groups, with nonproficient children's responses being more visual and less auditory than those of proficient children. Further analysis revealed that differences between visually clear and visually reduced conditions and between

  9. Bilateral Sequential Cochlear Implantation in Patients With Enlarged Vestibular Aqueduct (EVA) Syndrome.

    PubMed

    Manzoor, Nauman F; Wick, Cameron C; Wahba, Marian; Gupta, Amit; Piper, Robin; Murray, Gail S; Otteson, Todd; Megerian, Cliff A; Semaan, Maroun T

    2016-02-01

    To analyze audiometric outcomes after bilateral cochlear implantation in patients with isolated enlarged vestibular aqueduct (EVA) syndrome and associated incomplete partition (IP) malformations. Secondary objective was to analyze rate of cerebrospinal fluid (CSF) gusher in patients with IP-EVA spectrum deformities and compare this with the existing literature. Retrospective chart review. Thirty-two patients with EVA syndrome who received unilateral or bilateral cochlear implants between June 1999 and January 2014 were identified in the University Hospitals Case Medical Center cochlear implant database. Isolated EVA (IEVA) and Incomplete Partition Type II (IP-II) malformations were identified by reviewing high-resolution computed tomography (HRCT) imaging. Demographic information, age at implantation, surgical details, postimplantation audiometric data including speech reception thresholds (SRT), word, and sentence scores were reviewed and analyzed. Intra- and postoperative complications were analyzed as well and compared with the literature. Seventeen patients (32 implanted ears) had pediatric cochlear implantation for EVA-associated hearing loss. Data from 16 controls (32 implanted ears) were used to compare audiometric and speech outcomes of EVA cohort. Mean age at implantation was 6.8 years for EVA cohort and 6.0 years for controls. There was no statistically significant difference in long-term postoperative SRT, monaurally aided word scores, and binaurally tested word scores between pediatric EVA group and controls. The EVA patients had a long-term mean sentence score of 85.92%. A subset of EVA patients implanted at mean age of 3.18 years (n = 15 ears) had similar audiometric outcomes to another control group with Connexin 26 mutations (n = 20 ears) implanted at a similar age. Further subset analysis revealed no significant differences in age at implantation, SRT, and word scores in patients with IEVA and IP-II malformation. There was no significant

  10. [Audiophonological evaluation of 16 children fitted with cochlear implants for sensorineural hearing loss induced by bacterial meningitis].

    PubMed

    Teissier, N; Doehring, I; Noel-Petroff, N; Elmaleh-Bergès, M; Viala, P; François, M; Faye, A; Van Den Abbeele, T; Lorrot, M

    2013-06-01

    Bacterial meningitis (BM) is the primary etiology of acquired sensorineural hearing loss (SNHL) in children and may compromise language development. Since the 1990 s, cochlear implants (CIs) have become part of the management of children with profound SNHL with encouraging results. The aim of this study was to analyze the audiophonological performance of children before and after cochlear implantation for SNHL following bacterial meningitis. Retrospective study of all children fitted with CIs for bilateral severe to profound SNHL after bacterial meningitis in the Robert-Debré pediatric ENT department between August 1990 and March 2009. Audiophonological performance was assessed using the APCEI profile. Of the 283 children receiving implants during that period, 16 children (6%; 6 boys, 10 girls) underwent CI implantation after bacterial meningitis (Streptococcus pneumoniae in 8 cases, Neisseria meningitidis in 2 cases, and Haemophilus influenzae in 4 cases). The mean time from meningitis to SNHL was 8.3 months (median, 1.5 months; range, 1 day to 13 years). The mean time from meningitis to cochlear implantation was 2 years and 3 months (median, 7 months; range, 1 month to 13 years 3 months). Twelve children (75%) presented partial cochlear and/or vestibular ossification on presurgical CT scan. Three children received bilateral implants. Thirteen children (81%) developed early SNHL in the first 3 months, whereas 3 children developed SNHL more than 10 months after meningitis. As for the benefits of cochlear implantation, 11 children presented near to normal intelligibility and optimal use of their cochlear implant; 5 children presented partial benefits due to neurological sequelae (1), a long delay before implantation (1), technical problems (2), or a social problem in relation to low socioeconomic status (1). After bacterial meningitis, audiological evaluation must be made carefully during the first 3 months to detect early SNHL, but SNHL may also develop several

  11. Predicting social functioning in children with a cochlear implant and in normal-hearing children: the role of emotion regulation.

    PubMed

    Wiefferink, Carin H; Rieffe, Carolien; Ketelaar, Lizet; Frijns, Johan H M

    2012-06-01

    The purpose of the present study was to compare children with a cochlear implant and normal hearing children on aspects of emotion regulation (emotion expression and coping strategies) and social functioning (social competence and externalizing behaviors) and the relation between emotion regulation and social functioning. Participants were 69 children with cochlear implants (CI children) and 67 normal hearing children (NH children) aged 1.5-5 years. Parents answered questionnaires about their children's language skills, social functioning, and emotion regulation. Children also completed simple tasks to measure their emotion regulation abilities. Cochlear implant children had fewer adequate emotion regulation strategies and were less socially competent than normal hearing children. The parents of cochlear implant children did not report fewer externalizing behaviors than those of normal hearing children. While social competence in normal hearing children was strongly related to emotion regulation, cochlear implant children regulated their emotions in ways that were unrelated with social competence. On the other hand, emotion regulation explained externalizing behaviors better in cochlear implant children than in normal hearing children. While better language skills were related to higher social competence in both groups, they were related to fewer externalizing behaviors only in cochlear implant children. Our results indicate that cochlear implant children have less adequate emotion-regulation strategies and less social competence than normal hearing children. Since they received their implants relatively recently, they might eventually catch up with their hearing peers. Longitudinal studies should further explore the development of emotion regulation and social functioning in cochlear implant children. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  12. Cochlear Implants in Children with Hearing Loss: Maternal Expectations and Impact on the Family

    ERIC Educational Resources Information Center

    Zaidman-Zait, Anat; Most, Tova

    2005-01-01

    To facilitate evaluations of cochlear implant candidates and to promote (re)habilitation efficacy and collaboration with families, this study examined the expectations of 35 mothers with typical hearing and their beliefs and difficulties related to their child's hearing loss and current or future cochlear implantation. Questionnaires measured…

  13. Radiology of Osteogenesis Imperfecta, Rickets and Other Bony Fragility States.

    PubMed

    Calder, Alistair D

    2015-01-01

    This section gives an overview of radiological findings in bony fragility states, with a special focus on osteogenesis imperfecta (OI) and rickets. Conventional radiological assessment of bone density is inaccurate and imprecise and only reliably detects severe osteopaenia. However, other aspects of bone structure and morphology can be assessed, and it is possible to distinguish between osteopaenic and osteomalacic states. OI is a heterogeneous group of disorders of type 1 collagen formation and processing that are characterised by varying degrees of bony fragility, with presentations varying from perinatal lethality to asymptomatic. Radiological diagnosis of severe forms is usually straightforward, but that of milder disease may be challenging because specific features are often absent. However, a multidisciplinary approach is usually successful. Features of OI, including Wormian bones, skull base deformities, vertebral involvement and long bone fractures and deformities, are reviewed in this section. Rickets is best defined as a disorder of the growth plate characterised by the impaired apoptosis of hypertrophied chondrocytes. Vitamin D deficiency is a common cause of rickets. The patho-anatomical basis of radiological findings in rickets is reviewed and illustrated. Rickets is frequently accompanied by hyperparathyroidism and osteomalacia. Rickets used to be classified as calciopaenic or phosphopaenic but is now referred to as parathyroid hormone or fibroblast growth factor 23 mediated, respectively [1]. The radiological features of the two forms are reviewed. © 2015 S. Karger AG, Basel.

  14. Electrophysiological evidence for altered visual, but not auditory, selective attention in adolescent cochlear implant users.

    PubMed

    Harris, Jill; Kamke, Marc R

    2014-11-01

    Selective attention fundamentally alters sensory perception, but little is known about the functioning of attention in individuals who use a cochlear implant. This study aimed to investigate visual and auditory attention in adolescent cochlear implant users. Event related potentials were used to investigate the influence of attention on visual and auditory evoked potentials in six cochlear implant users and age-matched normally-hearing children. Participants were presented with streams of alternating visual and auditory stimuli in an oddball paradigm: each modality contained frequently presented 'standard' and infrequent 'deviant' stimuli. Across different blocks attention was directed to either the visual or auditory modality. For the visual stimuli attention boosted the early N1 potential, but this effect was larger for cochlear implant users. Attention was also associated with a later P3 component for the visual deviant stimulus, but there was no difference between groups in the later attention effects. For the auditory stimuli, attention was associated with a decrease in N1 latency as well as a robust P3 for the deviant tone. Importantly, there was no difference between groups in these auditory attention effects. The results suggest that basic mechanisms of auditory attention are largely normal in children who are proficient cochlear implant users, but that visual attention may be altered. Ultimately, a better understanding of how selective attention influences sensory perception in cochlear implant users will be important for optimising habilitation strategies. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  15. Technical survey of the French role in multichannel cochlear implant development.

    PubMed

    Chouard, Claude-Henri

    2015-06-01

    The objective of this review is to remind the ENT community of the essential role of the French teams in the development and finalization of the multi-electrode cochlear implant (MCI), which has deliberately been neglected, and to repair the oblivion into which France was curiously cast at the end of the last century. It aims to underline significant scientific publications from the researchers who played key roles in the development of MCIs. In conclusion, the Parisian team of the ENT Lab in Saint Antoine Hospital in Paris can claim priority for its work in five regards. We were the first: (1) to plot in 1976 a frequency map of the whole length of three living human cochleas; (2) on September 22, 1976, to set up total cochlear implantation in a deaf adult male with eight electrodes; (3) on March 16, 1977, to apply for a patent for an implantable hearing aid in humans; (4) to describe sound signal processing (SSP) for a functional cochlear implant able to supply totally deaf patients with speech discrimination without the help of lip-reading; (5) in 1983, to experimentally demonstrate why it was necessary to place a cochlear implant as early as possible, in case of profound neonatal deafness. An injustice has occurred. These facts will be brought to the knowledge of the scientific community.

  16. A mathematical model of vowel identification by users of cochlear implants

    PubMed Central

    Sagi, Elad; Meyer, Ted A.; Kaiser, Adam R.; Teoh, Su Wooi; Svirsky, Mario A.

    2010-01-01

    A simple mathematical model is presented that predicts vowel identification by cochlear implant users based on these listeners’ resolving power for the mean locations of first, second, and∕or third formant energies along the implanted electrode array. This psychophysically based model provides hypotheses about the mechanism cochlear implant users employ to encode and process the input auditory signal to extract information relevant for identifying steady-state vowels. Using one free parameter, the model predicts most of the patterns of vowel confusions made by users of different cochlear implant devices and stimulation strategies, and who show widely different levels of speech perception (from near chance to near perfect). Furthermore, the model can predict results from the literature, such as Skinner, et al. [(1995). Ann. Otol. Rhinol. Laryngol. 104, 307–311] frequency mapping study, and the general trend in the vowel results of Zeng and Galvin’s [(1999). Ear Hear. 20, 60–74] studies of output electrical dynamic range reduction. The implementation of the model presented here is specific to vowel identification by cochlear implant users, but the framework of the model is more general. Computational models such as the one presented here can be useful for advancing knowledge about speech perception in hearing impaired populations, and for providing a guide for clinical research and clinical practice. PMID:20136228

  17. Benefits of Localization and Speech Perception with Multiple Noise Sources in Listeners with a Short-electrode Cochlear Implant

    PubMed Central

    Dunn, Camille C.; Perreau, Ann; Gantz, Bruce; Tyler, Richard

    2009-01-01

    Background Research suggests that for individuals with significant low-frequency hearing, implantation of a short-electrode cochlear implant may provide benefits of improved speech perception abilities. Because this strategy combines acoustic and electrical hearing within the same ear while at the same time preserving low-frequency residual acoustic hearing in both ears, localization abilities may also be improved. However, very little research has focused on the localization and spatial hearing abilities of users with a short-electrode cochlear implant. Purpose The purpose of this study was to evaluate localization abilities for listeners with a short-electrode cochlear implant who continue to wear hearing aids in both ears. A secondary purpose was to document speech perception abilities using a speech in noise test with spatially-separate noise sources. Research Design Eleven subjects that utilized a short-electrode cochlear implant and bilateral hearing aids were tested on localization and speech perception with multiple noise locations using an eight-loudspeaker array. Performance was assessed across four listening conditions using various combinations of cochlear implant and/or hearing aid use. Results Results for localization showed no significant difference between using bilateral hearing aids and bilateral hearing aids plus the cochlear implant. However, there was a significant difference between the bilateral hearing aid condition and the implant plus use of a contralateral hearing aid for all eleven subjects. Results for speech perception showed a significant benefit when using bilateral hearing aids plus the cochlear implant over use of the implant plus only one hearing aid. Conclusion Combined use of both hearing aids and the cochlear implant show significant benefits for both localization and speech perception in noise for users with a short-electrode cochlear implant. These results emphasize the importance of low-frequency information in two ears for

  18. Benefits of localization and speech perception with multiple noise sources in listeners with a short-electrode cochlear implant.

    PubMed

    Dunn, Camille C; Perreau, Ann; Gantz, Bruce; Tyler, Richard S

    2010-01-01

    Research suggests that for individuals with significant low-frequency hearing, implantation of a short-electrode cochlear implant may provide benefits of improved speech perception abilities. Because this strategy combines acoustic and electrical hearing within the same ear while at the same time preserving low-frequency residual acoustic hearing in both ears, localization abilities may also be improved. However, very little research has focused on the localization and spatial hearing abilities of users with a short-electrode cochlear implant. The purpose of this study was to evaluate localization abilities for listeners with a short-electrode cochlear implant who continue to wear hearing aids in both ears. A secondary purpose was to document speech perception abilities using a speech-in-noise test with spatially separate noise sources. Eleven subjects that utilized a short-electrode cochlear implant and bilateral hearing aids were tested on localization and speech perception with multiple noise locations using an eight-loudspeaker array. Performance was assessed across four listening conditions using various combinations of cochlear implant and/or hearing aid use. Results for localization showed no significant difference between using bilateral hearing aids and bilateral hearing aids plus the cochlear implant. However, there was a significant difference between the bilateral hearing aid condition and the implant plus use of a contralateral hearing aid for all 11 subjects. Results for speech perception showed a significant benefit when using bilateral hearing aids plus the cochlear implant over use of the implant plus only one hearing aid. Combined use of both hearing aids and the cochlear implant show significant benefits for both localization and speech perception in noise for users with a short-electrode cochlear implant. These results emphasize the importance of low-frequency information in two ears for the purpose of localization and speech perception in noise.

  19. Cochlear implant – state of the art

    PubMed Central

    Lenarz, Thomas

    2018-01-01

    Cochlear implants are the treatment of choice for auditory rehabilitation of patients with sensory deafness. They restore the missing function of inner hair cells by transforming the acoustic signal into electrical stimuli for activation of auditory nerve fibers. Due to the very fast technology development, cochlear implants provide open-set speech understanding in the majority of patients including the use of the telephone. Children can achieve a near to normal speech and language development provided their deafness is detected early after onset and implantation is performed quickly thereafter. The diagnostic procedure as well as the surgical technique have been standardized and can be adapted to the individual anatomical and physiological needs both in children and adults. Special cases such as cochlear obliteration might require special measures and re-implantation, which can be done in most cases in a straight forward way. Technology upgrades count for better performance. Future developments will focus on better electrode-nerve interfaces by improving electrode technology. An increased number of electrical contacts as well as the biological treatment with regeneration of the dendrites growing onto the electrode will increase the number of electrical channels. This will give room for improved speech coding strategies in order to create the bionic ear, i.e. to restore the process of natural hearing by means of technology. The robot-assisted surgery will allow for high precision surgery and reliable hearing preservation. Biological therapies will support the bionic ear. Methods are bio-hybrid electrodes, which are coded by stem cells transplanted into the inner ear to enhance auto-production of neurotrophins. Local drug delivery will focus on suppression of trauma reaction and local regeneration. Gene therapy by nanoparticles will hopefully lead to the preservation of residual hearing in patients being affected by genetic hearing loss. Overall the cochlear implant

  20. Ethical considerations in resource allocation in a cochlear implant program.

    PubMed

    Westerberg, Brian D; Pijl, Sipke; McDonald, Michael

    2008-04-01

    To review processes of resource allocation and the ethical considerations relevant to the fair allocation of a limited number of cochlear implants to increasing numbers of potential recipients. Review of relevant considerations. Tertiary referral hospital. Editorial discussion of the ethical issues of resource allocation. Heterogeneity of audiometric thresholds, self-reported disability of hearing loss, age of the potential cochlear implant recipient, cost-effectiveness, access to resources, compliance with follow-up, social support available to the recipient, social consequences of hearing impairment, and other recipient-related factors. In a publicly funded health care system, there will always be a need for decision-making processes for allocation of finite fiscal resources. All candidates for cochlear implantation deserve fair consideration. However, they are a heterogeneous group in terms of needs and expected outcomes consisting of traditional and marginal candidates, with a wide range of benefit from acoustic amplification. We argue that implant programs should thoughtfully prioritize treatment on the basis of need and potential benefit. We reject queuing on the basis of "first-come, first-served" or on the basis of perceived social worth.

  1. Optical coherence tomography as a guide for cochlear implant surgery?

    NASA Astrophysics Data System (ADS)

    Just, T.; Lankenau, E.; Hüttmann, G.; Pau, H. W.

    2008-02-01

    To assess the potential use of optical coherence tomography (OCT) in cochlear implant surgery, OCT was applied in human temporal bones before cochleostomy. The question was whether OCT might provide information about the cochlear topography, especially about the site of the scala tympani. OCT was carried out on human temporal bone preparations, in which the cochleostomy was performed leaving the membranous labyrinth and the fluid-filled inner ear intact. A specially equipped operating microscope with integrated OCT prototype was used. Spectral-domain (SD)-OCT was used for all investigations. On all scans, OCT supplied information about inner ear structures, such as scala tympani, scala vestibuli while the membranous labyrinth was still intact. In the fresh temporal bone the scala media, basilar membrane and the Reissner's membrane were identified. This OCT study clearly documents the possibility to identify inner ear structures, especially the scala tympani without opening its enveloping membranes. These findings may have an impact on cochlear implant surgery, especially as an orientation guide to localize the scala tympani precisely before opening the fluid filled inner ear.

  2. Vocabulary Knowledge of Children With Cochlear Implants: A Meta-Analysis

    PubMed Central

    2016-01-01

    This article employs meta-analysis procedures to evaluate whether children with cochlear implants demonstrate lower spoken-language vocabulary knowledge than peers with normal hearing. Of the 754 articles screened and 52 articles coded, 12 articles met predetermined inclusion criteria (with an additional 5 included for one analysis). Effect sizes were calculated for relevant studies and forest plots were used to compare differences between groups of children with normal hearing and children with cochlear implants. Weighted effect size averages for expressive vocabulary measures (g = −11.99; p < .001) and for receptive vocabulary measures (g = −20.33; p < .001) indicated that children with cochlear implants demonstrate lower vocabulary knowledge than children with normal hearing. Additional analyses confirmed the value of comparing vocabulary knowledge of children with hearing loss to a tightly matched (e.g., socioeconomic status-matched) sample. Age of implantation, duration of implantation, and chronological age at testing were not significantly related to magnitude of weighted effect size. Findings from this analysis represent a first step toward resolving discrepancies in the vocabulary knowledge literature. PMID:26712811

  3. The case for earlier cochlear implantation in postlingually deaf adults.

    PubMed

    Dowell, Richard C

    2016-01-01

    This paper aimed to estimate the difference in speech perception outcomes that may occur due to timing of cochlear implantation in relation to the progression of hearing loss. Data from a large population-based sample of adults with acquired hearing loss using cochlear implants (CIs) was used to estimate the effects of duration of hearing loss, age, and pre-implant auditory skills on outcomes for a hypothetical standard patient. A total of 310 adults with acquired severe/profound bilateral hearing loss who received a CI in Melbourne, Australia between 1994 and 2006 provided the speech perception data and demographic information to derive regression equations for estimating CI outcomes. For a hypothetical CI candidate with progressive sensorineural hearing loss, the estimates of speech perception scores following cochlear implantation are significantly better if implantation occurs relatively soon after onset of severe hearing loss and before the loss of all functional auditory skills. Improved CI outcomes and quality of life benefit may be achieved for adults with progressive severe hearing loss if they are implanted earlier in the progression of the pathology.

  4. Standardization of reliability reporting for cochlear implants: an interim report.

    PubMed

    Backous, Douglas D; Watson, Stacey D

    2007-04-01

    To propose a standard definition of "out of specification" for cochlear implants and a paradigm for inclusion of category C of the ISO standard 5841-2:2000 for reporting in cumulative survival statistics. A standard definition of "out of specification" and consistent reporting by manufacturers of cochlear implants will create a fair and consistent representation of cumulative survival. This will allow discernment of differences between manufacturers for reliability and for detection of trends in reliability between model types from the same manufacturer. Three separate meetings with representatives of the three manufacturers of cochlear implants marketed in the United States were staged over a 13-mo period. Standard questions, created by the authors, were addressed by each representative to determine the current state of device reliability reporting. Results were presented to clinicians at the William House Cochlear Implant study Group and the Implantable devices sub-committee of the American Academy of Otolaryngology (2004, 2005) and at the 8th International Cochlear Implant Conference (2004) for feedback. After assimilation of feedback by all parties, the standard was written and reviewed by representatives from each manufacturer for accuracy of data. A complaint-driven standard was developed. A "cochlear implant" as an internal device placed and skin closed in surgery. An internal device is "out of specification" when one or more technical characteristics is outside the limits of normal function and results in explantation or non-use by the patient." Children will be reported separately from adults, each model of device will be reported on annually, a minimum of 200 devices must be in each model group for Cumulative Survival Reporting (CSR). Confidence limits are set at 95%. Explants will be determined to be "biological" or "technical." Technical explants are included in CSR reports. Devices failing to meet specifications set by the manufacturer, not in use but

  5. Modifying cochlear implant design: advantages of placing a return electrode in the modiolus.

    PubMed

    Ho, Steven Y; Wiet, Richard J; Richter, Claus-Peter

    2004-07-01

    A modiolar return electrode significantly increases the current flow across spiral ganglion cells into the modiolus, and may decrease the cochlear implant's power requirements. Ideal cochlear implants should maximize current flow into the modiolus to stimulate auditory neurons. Previous efforts to facilitate current flow through the modiolus included the fabrication and use of precurved electrodes designed to "hug" the modiolus and silastic positioners designed to place the electrodes closer to the modiolus. In contrast to earlier efforts, this study explores the effects of return electrode placement on current distributions in the modiolus. The effects of return electrode positioning on current flow in the modiolus were studied in a Plexiglas model of the cochlea. Results of model measurements were confirmed by measurements in the modiolus of human temporal bones. The return electrode was placed either within the modiolus, or remotely, outside the temporal bone, simulating contemporary cochlear implant configurations using monopolar stimulation. Cochlear model results clearly show that modiolar current amplitudes can be influenced significantly by the location of the return electrode, being larger when placed into the modiolus. Temporal bone data show similar findings. Voltages recorded in the modiolus are, on average, 2.8 times higher with the return electrode in the modiolus compared with return electrode locations outside the temporal bone. Placing a cochlear implant's return electrode in the modiolus should significantly reduce its power consumption. Reducing power requirements should lead to improved efficiency, safer long-term use, and longer device life.

  6. Communication benefits of bilateral cochlear implantation. Retrospective study in 12-year-old children.

    PubMed

    Guerra-Jiménez, Gloria; Viera Artiles, Jaime; Mateos, Mar; González Aguado, Rocío; Falcón González, Juan Carlos; Borkoski Barreiro, Silvia; Ramos Macías, Angel

    2013-01-01

    Some studies suggest that simultaneous or sequential cochlear implantation in a short period of time offers additional benefits. There is controversy regarding the existence of an age limit after which a second implantation offers less benefit for the acquisition of communication skills. The objectives of this study were to confirm that sequential cochlear implantation offers benefits compared to unilateral implantation and to study whether, at 12 years of age, there are significant differences regarding the age at the time of the second implantation. Descriptive and observational study of a population of 12-year-old children carrying cochlear implants (n=69). A liminal pure tone audiometry and an open-field verbal discrimination test (disyllables, common phrases in an open context, with and without noise) were conducted to evaluate audiological benefits. Verbal discrimination results were better among patients who had been implanted before the age of 2 years, although the differences were not statistically significant (P>.5). Children who had received bilateral cochlear implants before the age of 2 years and with a period less than 4 years between both implants presented better verbal discrimination percentages (P<.05). In our sample, early cochlear implantation with a short period between both implants provided significant benefits regarding intelligibility. There seem to be a specific age and interimplant period, after which the auditory benefit on the first implant becomes reduced. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  7. Pediatric cochlear implants: additional disabilities prevalence, risk factors, and effect on language outcomes.

    PubMed

    Birman, Catherine S; Elliott, Elizabeth J; Gibson, William P R

    2012-10-01

    To determine the prevalence of additional disabilities in a pediatric cochlear population, to identify medical and radiologic conditions associated with additional disabilities, and to identify the effect of additional disabilities on speech perception and language at 12 months postoperatively. Retrospective case review. Tertiary referral center and cochlear implant program. Records were reviewed for children 0 to 16 years old inclusive, who had cochlear implant-related operations over a 12-month period. Diagnostic and rehabilitative. Additional disabilities prevalence; medical history and radiologic abnormalities; and the effect on Categories of Auditory Performance (CAP) score at 12 months postoperatively. Eighty-eight children having 96 operations were identified. The overall prevalence of additional disabilities (including developmental delay, cerebral palsy, visual impairment, autism and attention deficit disorder) was 33%. The main conditions associated with additional disabilities were syndromes and chromosomal abnormalities (87%), jaundice (86%), prematurity (62%), cytomegalovirus (60%), and inner ear abnormalities including cochlea nerve hypoplasia or aplasia (75%) and semicircular canal anomalies (56%). At 12 months postoperatively, almost all (96%) of the children without additional disabilities had a CAP score of 5 or greater (speech), compared with 52% of children with additional disabilities. Children with developmental delay had a median CAP score of 4, at 12 months compared with 6 for those without developmental delay. Additional disabilities are prevalent in approximately a third of pediatric cochlear implant patients. Additional disabilities significantly affect the outcomes of cochlear implants.

  8. Modelling the effect of round window stiffness on residual hearing after cochlear implantation.

    PubMed

    Elliott, Stephen J; Ni, Guangjian; Verschuur, Carl A

    2016-11-01

    Preservation of residual hearing after cochlear implantation is now considered an important goal of surgery. However, studies indicate an average post-operative hearing loss of around 20 dB at low frequencies. One factor which may contribute to post-operative hearing loss, but which has received little attention in the literature to date, is the increased stiffness of the round window, due to the physical presence of the cochlear implant, and to its subsequent thickening or to bone growth around it. A finite element model was used to estimate that there is approximately a 100-fold increase in the round window stiffness due to a cochlear implant passing through it. A lumped element model was then developed to study the effects of this change in stiffness on the acoustic response of the cochlea. As the round window stiffness increases, the effects of the cochlear and vestibular aqueducts become more important. An increase of round window stiffness by a factor of 10 is predicted to have little effect on residual hearing, but increasing this stiffness by a factor of 100 reduces the acoustic sensitivity of the cochlea by about 20 dB, below 1 kHz, in reasonable agreement with the observed loss in residual hearing after implantation. It is also shown that the effect of this stiffening could be reduced by incorporating a small gas bubble within the cochlear implant. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  9. Speech recognition and communication outcomes with cochlear implantation in Usher syndrome type 3.

    PubMed

    Pietola, Laura; Aarnisalo, Antti A; Abdel-Rahman, Akram; Västinsalo, Hanna; Isosomppi, Juha; Löppönen, Heikki; Kentala, Erna; Johansson, Reijo; Valtonen, Hannu; Vasama, Juha-Pekka; Sankila, Eeva-Marja; Jero, Jussi

    2012-01-01

    Usher syndrome Type 3 (USH3) is an autosomal recessive disorder characterized by variable type and degree of progressive sensorineural hearing loss and retinitis pigmentosa. Cochlear implants are widely used among these patients. To evaluate the results and benefits of cochlear implantation in patients with USH3. A nationwide multicenter retrospective review. During the years 1995-2005, in 5 Finnish university hospitals, 19 patients with USH3 received a cochlear implant. Saliva samples were collected to verify the USH3 genotype. Patients answered to 3 questionnaires: Glasgow Benefit Inventory, Glasgow Health Status Inventory, and a self-made questionnaire. Audiological data were collected from patient records. All the patients with USH3 in the study were homozygous for the Finnish major mutation (p.Y176X). Either they had severe sensorineural hearing loss or they were profoundly deaf. The mean preoperative hearing level (pure-tone average, 0.5-4 kHz) was 110 ± 8 dB hearing loss (HL) and the mean aided hearing level was 58 ± 11 dB HL. The postoperative hearing level (34 ± 9 dB HL) and word recognition scores were significantly better than before surgery. According to the Glasgow Benefit Inventory scores and Glasgow Health Status Inventory data related to hearing, the cochlear implantation was beneficial to patients with USH3. Cochlear implantation is beneficial to patients with USH3, and patients learn to use the implant without assistance.

  10. Wired to freedom: Life science, public politics, and the case of Cochlear Implantation.

    PubMed

    Jepsen, Kim Sune; Bertilsson, T Margareta

    2017-02-01

    Cochlear Implantation is now regarded as the most successful medical technology. It carries promises to provide deaf/hearing impaired individuals with a technological sense of hearing and an access to participate on a more equal level in social life. In this article, we explore the adoption of cochlear implantations among Danish users in order to shed more light on their social and political implications. We situate cochlear implantation in a framework of new life science advances, politics, and user experiences. Analytically, we draw upon the notion of social imaginary and explore the social dimension of life science through a notion of public politics adopted from the political theory of John Dewey. We show how cochlear implantation engages different social imaginaries on the collective and individual levels and we suggest that users share an imaginary of being "wired to freedom" that involves new access to social life, continuous communicative challenges, common practices, and experiences. In looking at their lives as "wired to freedom," we hope to promote a wider spectrum of civic participation in the benefit of future life science developments within and beyond the field of Cochlear Implantation. As our empirical observations are largely based in the Scandinavian countries (notably Denmark), we also provide some reflections on the character of the technology-friendly Scandinavian welfare states and the unintended consequences that may follow in the wake of rapid technology implementation of life science in society.

  11. Development of micro-electromechanical system (MEMS) cochlear biomodel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ngelayang, Thailis Bounya Anak; Latif, Rhonira

    Human cochlear is undeniably one of the most amazing organs in human body. The functional mechanism is very unique in terms of its ability to convert the sound waves in the form of mechanical vibrations into the electrical nerve impulses. It is known that the normal human auditory system can perceive the audible frequency range between 20 Hz to 20 kHz. Scientists have conducted several researches trying to build the artificial basilar membrane in the human cochlea (cochlear biomodel). Micro-electromechanical system (MEMS) is one of the potential inventions that have the ability to mimic the active behavior of the basilar membrane. Inmore » this paper, an array of MEMS bridge beams that are mechanically sensitive to the perceived audible frequency has been proposed. An array of bridge bridge beams with 0.5 µm thickness and length varying from 200 µm to 2000 µm have been designed operate within the audible frequency range. In the bridge beams design, aluminium (Al), copper (Cu), tantalum (Ta) and platinum (Pt) have considered as the material for the bridge beam structure. From the finite element (FE) and lumped element (LE) models of the MEMS bridge beams, platinum has been found to be the best material for the cochlear biomodel design, closely mimicking the basilar membrane.« less

  12. Evaluation of Mandarin Chinese Speech Recognition in Adults with Cochlear Implants Using the Spectral Ripple Discrimination Test

    PubMed Central

    Dai, Chuanfu; Zhao, Zeqi; Zhang, Duo; Lei, Guanxiong

    2018-01-01

    Background The aim of this study was to explore the value of the spectral ripple discrimination test in speech recognition evaluation among a deaf (post-lingual) Mandarin-speaking population in China following cochlear implantation. Material/Methods The study included 23 Mandarin-speaking adult subjects with normal hearing (normal-hearing group) and 17 deaf adults who were former Mandarin-speakers, with cochlear implants (cochlear implantation group). The normal-hearing subjects were divided into men (n=10) and women (n=13). The spectral ripple discrimination thresholds between the groups were compared. The correlation between spectral ripple discrimination thresholds and Mandarin speech recognition rates in the cochlear implantation group were studied. Results Spectral ripple discrimination thresholds did not correlate with age (r=−0.19; p=0.22), and there was no significant difference in spectral ripple discrimination thresholds between the male and female groups (p=0.654). Spectral ripple discrimination thresholds of deaf adults with cochlear implants were significantly correlated with monosyllabic recognition rates (r=0.84; p=0.000). Conclusions In a Mandarin Chinese speaking population, spectral ripple discrimination thresholds of normal-hearing individuals were unaffected by both gender and age. Spectral ripple discrimination thresholds were correlated with Mandarin monosyllabic recognition rates of Mandarin-speaking in post-lingual deaf adults with cochlear implants. The spectral ripple discrimination test is a promising method for speech recognition evaluation in adults following cochlear implantation in China. PMID:29806954

  13. Evaluation of Mandarin Chinese Speech Recognition in Adults with Cochlear Implants Using the Spectral Ripple Discrimination Test.

    PubMed

    Dai, Chuanfu; Zhao, Zeqi; Shen, Weidong; Zhang, Duo; Lei, Guanxiong; Qiao, Yuehua; Yang, Shiming

    2018-05-28

    BACKGROUND The aim of this study was to explore the value of the spectral ripple discrimination test in speech recognition evaluation among a deaf (post-lingual) Mandarin-speaking population in China following cochlear implantation. MATERIAL AND METHODS The study included 23 Mandarin-speaking adult subjects with normal hearing (normal-hearing group) and 17 deaf adults who were former Mandarin-speakers, with cochlear implants (cochlear implantation group). The normal-hearing subjects were divided into men (n=10) and women (n=13). The spectral ripple discrimination thresholds between the groups were compared. The correlation between spectral ripple discrimination thresholds and Mandarin speech recognition rates in the cochlear implantation group were studied. RESULTS Spectral ripple discrimination thresholds did not correlate with age (r=-0.19; p=0.22), and there was no significant difference in spectral ripple discrimination thresholds between the male and female groups (p=0.654). Spectral ripple discrimination thresholds of deaf adults with cochlear implants were significantly correlated with monosyllabic recognition rates (r=0.84; p=0.000). CONCLUSIONS In a Mandarin Chinese speaking population, spectral ripple discrimination thresholds of normal-hearing individuals were unaffected by both gender and age. Spectral ripple discrimination thresholds were correlated with Mandarin monosyllabic recognition rates of Mandarin-speaking in post-lingual deaf adults with cochlear implants. The spectral ripple discrimination test is a promising method for speech recognition evaluation in adults following cochlear implantation in China.

  14. Ischemia-reperfusion injury of the cochlea: pharmacological strategies for cochlear protection and implications of glutamate and reactive oxygen species.

    PubMed

    Tabuchi, Keiji; Nishimura, Bungo; Tanaka, Shuho; Hayashi, Kentaro; Hirose, Yuki; Hara, Akira

    2010-06-01

    A large amount of energy produced by active aerobic metabolism is necessary for the cochlea to maintain its function. This makes the cochlea vulnerable to blockade of cochlear blood flow and interruption of the oxygen supply. Although certain forms of human idiopathic sudden sensorineural hearing loss reportedly arise from ischemic injury, the pathological mechanism of cochlear ischemia-reperfusion injury has not been fully elucidated. Recent animal studies have shed light on the mechanisms of cochlear ischemia-reperfusion injury. It will help in the understanding of the pathology of cochlear ischemia-reperfusion injury to classify this injury into ischemic injury and reperfusion injury. Excitotoxicity, mainly observed during the ischemic period, aggravates the injury of primary auditory neurons. On the other hand, oxidative damage induced by hydroxyl radicals and nitric oxide enhances cochlear reperfusion injury. This article briefly summarizes the generation mechanisms of cochlear ischemia-reperfusion injury and potential therapeutic targets that could be developed for the effective management of this injury type.

  15. Fabrication and evaluation of an improved polymer-based cochlear electrode array for atraumatic insertion.

    PubMed

    Gwon, Tae Mok; Min, Kyou Sik; Kim, Jin Ho; Oh, Seung Ha; Lee, Ho Sun; Park, Min-Hyun; Kim, Sung June

    2015-04-01

    An atraumatic cochlear electrode array has become indispensable to high-performance cochlear implants such as electric acoustic stimulation (EAS), wherein the preservation of residual hearing is significant. For an atraumatic implantation, we propose and demonstrate a new improved design of a cochlear electrode array based on liquid crystal polymer (LCP), which can be fabricated by precise batch processes and a thermal lamination process, in contrast to conventional wire-based cochlear electrode arrays. Using a thin-film process of LCP-film-mounted silicon wafer and thermal press lamination, we devise a multi-layered structure with variable layers of LCP films to achieve a sufficient degree of basal rigidity and a flexible tip. A peripheral blind via and self-aligned silicone elastomer molding process can reduce the width of the array. Measuring the insertion and extraction forces in a human scala tympani model, we investigate five human temporal bone insertion trials and record electrically evoked auditory brainstem responses (EABR) acutely in a guinea pig model. The diameters of the finalized electrode arrays are 0.3 mm (tip) and 0.75 mm (base). The insertion force with a displacement of 8 mm from a round window and the maximum extraction force are 2.4 mN and 34.0 mN, respectively. The electrode arrays can be inserted from 360° to 630° without trauma at the basal turn. The EABR data confirm the efficacy of the array. A new design of LCP-based cochlear electrode array for atraumatic implantation is fabricated. Verification indicates that foretells the development of an atraumatic cochlear electrode array and clinical implant.

  16. Gender Categorization in Cochlear Implant Users

    ERIC Educational Resources Information Center

    Massida, Zoe; Marx, Mathieu; Belin, Pascal; James, Christopher; Fraysse, Bernard; Barone, Pascal; Deguine, Olivier

    2013-01-01

    Purpose: In this study, the authors examined the ability of subjects with cochlear implants (CIs) to discriminate voice gender and how this ability evolved as a function of CI experience. Method: The authors presented a continuum of voice samples created by voice morphing, with 9 intermediate acoustic parameter steps between a typical male and a…

  17. Vestibulo-ocular and vestibulospinal function before and after cochlear implant surgery

    NASA Technical Reports Server (NTRS)

    Black, F. O.; Lilly, D. J.; Peterka, R. J.; Fowler, L. P.; Simmons, F. B.

    1987-01-01

    Vestibular function in cochlear implant candidates varies from normal to total absence of function. In patients with intact vestibular function preoperatively, invasion of the otic capsule places residual vestibular function at risk. Speech-processing strategies that result in large amplitude electrical transients or strategies that employ high amplitude broad frequency carrier signals have the potential for disrupting vestibular function. Five patients were tested with and without electrical stimulation via cochlear electrodes. Two patients experienced subjective vestibular effects that were quickly resolved. No long-term vestibular effects were noted for the two types of second generation cochlear implants evaluated. Histopathological findings from another patient, who had electrically generated vestibular reflex responses to intramodiolar electrodes, indicated that responses elicited were a function of several variables including electrode location, stimulus intensity, stimulus amplitude, and stimulus frequency. Differential auditory, vestibulocolic, and vestibulospinal reflexes were demonstrated from the same electrode as a function of stimulus amplitude, frequency, and duration.

  18. Intraoperative Cochlear Implant Device Testing Utilizing an Automated Remote System: A Prospective Pilot Study.

    PubMed

    Lohmann, Amanda R; Carlson, Matthew L; Sladen, Douglas P

    2018-03-01

    Intraoperative cochlear implant device testing provides valuable information regarding device integrity, electrode position, and may assist with determining initial stimulation settings. Manual intraoperative device testing during cochlear implantation requires the time and expertise of a trained audiologist. The purpose of the current study is to investigate the feasibility of using automated remote intraoperative cochlear implant reverse telemetry testing as an alternative to standard testing. Prospective pilot study evaluating intraoperative remote automated impedance and Automatic Neural Response Telemetry (AutoNRT) testing in 34 consecutive cochlear implant surgeries using the Intraoperative Remote Assistant (Cochlear Nucleus CR120). In all cases, remote intraoperative device testing was performed by trained operating room staff. A comparison was made to the "gold standard" of manual testing by an experienced cochlear implant audiologist. Electrode position and absence of tip fold-over was confirmed using plain film x-ray. Automated remote reverse telemetry testing was successfully completed in all patients. Intraoperative x-ray demonstrated normal electrode position without tip fold-over. Average impedance values were significantly higher using standard testing versus CR120 remote testing (standard mean 10.7 kΩ, SD 1.2 vs. CR120 mean 7.5 kΩ, SD 0.7, p < 0.001). There was strong agreement between standard manual testing and remote automated testing with regard to the presence of open or short circuits along the array. There were, however, two cases in which standard testing identified an open circuit, when CR120 testing showed the circuit to be closed. Neural responses were successfully obtained in all patients using both systems. There was no difference in basal electrode responses (standard mean 195.0 μV, SD 14.10 vs. CR120 194.5 μV, SD 14.23; p = 0.7814); however, more favorable (lower μV amplitude) results were obtained with the remote

  19. Encoding and decoding amplitude-modulated cochlear implant stimuli—a point process analysis

    PubMed Central

    Shea-Brown, Eric; Rubinstein, Jay T.

    2010-01-01

    Cochlear implant speech processors stimulate the auditory nerve by delivering amplitude-modulated electrical pulse trains to intracochlear electrodes. Studying how auditory nerve cells encode modulation information is of fundamental importance, therefore, to understanding cochlear implant function and improving speech perception in cochlear implant users. In this paper, we analyze simulated responses of the auditory nerve to amplitude-modulated cochlear implant stimuli using a point process model. First, we quantify the information encoded in the spike trains by testing an ideal observer’s ability to detect amplitude modulation in a two-alternative forced-choice task. We vary the amount of information available to the observer to probe how spike timing and averaged firing rate encode modulation. Second, we construct a neural decoding method that predicts several qualitative trends observed in psychophysical tests of amplitude modulation detection in cochlear implant listeners. We find that modulation information is primarily available in the sequence of spike times. The performance of an ideal observer, however, is inconsistent with observed trends in psychophysical data. Using a neural decoding method that jitters spike times to degrade its temporal resolution and then computes a common measure of phase locking from spike trains of a heterogeneous population of model nerve cells, we predict the correct qualitative dependence of modulation detection thresholds on modulation frequency and stimulus level. The decoder does not predict the observed loss of modulation sensitivity at high carrier pulse rates, but this framework can be applied to future models that better represent auditory nerve responses to high carrier pulse rate stimuli. The supplemental material of this article contains the article’s data in an active, re-usable format. PMID:20177761

  20. Vibration of the organ of Corti within the cochlear apex in mice

    PubMed Central

    Gao, Simon S.; Wang, Rosalie; Raphael, Patrick D.; Moayedi, Yalda; Groves, Andrew K.; Zuo, Jian; Applegate, Brian E.

    2014-01-01

    The tonotopic map of the mammalian cochlea is commonly thought to be determined by the passive mechanical properties of the basilar membrane. The other tissues and cells that make up the organ of Corti also have passive mechanical properties; however, their roles are less well understood. In addition, active forces produced by outer hair cells (OHCs) enhance the vibration of the basilar membrane, termed cochlear amplification. Here, we studied how these biomechanical components interact using optical coherence tomography, which permits vibratory measurements within tissue. We measured not only classical basilar membrane tuning curves, but also vibratory responses from the rest of the organ of Corti within the mouse cochlear apex in vivo. As expected, basilar membrane tuning was sharp in live mice and broad in dead mice. Interestingly, the vibratory response of the region lateral to the OHCs, the “lateral compartment,” demonstrated frequency-dependent phase differences relative to the basilar membrane. This was sharply tuned in both live and dead mice. We then measured basilar membrane and lateral compartment vibration in transgenic mice with targeted alterations in cochlear mechanics. Prestin499/499, Prestin−/−, and TectaC1509G/C1509G mice demonstrated no cochlear amplification but maintained the lateral compartment phase difference. In contrast, SfswapTg/Tg mice maintained cochlear amplification but did not demonstrate the lateral compartment phase difference. These data indicate that the organ of Corti has complex micromechanical vibratory characteristics, with passive, yet sharply tuned, vibratory characteristics associated with the supporting cells. These characteristics may tune OHC force generation to produce the sharp frequency selectivity of mammalian hearing. PMID:24920025

  1. Cochlear implant performance in children deafened by congenital cytomegalovirus-A systematic review.

    PubMed

    Kraaijenga, V J C; Van Houwelingen, F; Van der Horst, S F; Visscher, J; Huisman, J M L; Hollman, E J; Stegeman, I; Smit, A L

    2018-05-16

    Congenital cytomegalovirus (cCMV) infection is a major cause of sensorineural hearing loss in children. The objective of this systematic review was to compare performance in paediatric cochlear implant users with SNHL caused by cCMV compared to non-cCMV implantees. Systematic review SEARCH STRATEGY: PubMed, EMBASE and the Cochrane databases were searched from inception up to 15 May 2017 for children, cochlear implant, performance and their synonyms. Titles, abstracts and full texts were screened for eligibility. Directness of evidence and risk of bias were assessed. From the included studies, study characteristics and outcome data (speech perception, speech production, receptive language and auditory performance of cCMV groups and non-cCMV groups) were extracted. A total of 5280 unique articles were screened of which 28 were eligible for critical appraisal. After critical appraisal, 12 studies remained for data extraction. Seven of 12 studies showed worse performance after cochlear implantation in cCMV children compared to non-cCMV children. Worse performance in cCMV children was attributed to cCMV-related comorbidities in six of these studies. Available data on asymptomatic cCMV children compared to non-cCMV children did not reveal an unfavourable effect on cochlear implant performance. The available evidence reveals that cCMV children often have worse cochlear implant performance compared to non-cCMV children, which can be attributed to cCMV related comorbidities. We urge physicians to take into account the cCMV related comorbidities in the counselling of paediatric CI users deafened by cCMV. © 2018 The Authors. Clinical Otolaryngology Published by John Wiley & Sons Ltd.

  2. Cost-Utility Analysis of Cochlear Implantation in Australian Adults.

    PubMed

    Foteff, Chris; Kennedy, Steven; Milton, Abul Hasnat; Deger, Melike; Payk, Florian; Sanderson, Georgina

    2016-06-01

    Sequential and simultaneous bilateral cochlear implants are emerging as appropriate treatment options for Australian adults with sensory deficits in both cochleae. Current funding of Australian public hospitals does not provide for simultaneous bilateral cochlear implantation (CI) as a separate surgical procedure. Previous cost-effectiveness studies of sequential and simultaneous bilateral CI assumed 100% of unilaterally treated patients' transition to a sequential bilateral CI. This assumption does not place cochlear implantation in the context of the generally treated population. When mutually exclusive treatment options exist, such as unilateral CI, sequential bilateral CI, and simultaneous bilateral CI, the mean costs of the treated populations are weighted in the calculation of incremental cost-utility ratios. The objective was to evaluate the cost-utility of bilateral hearing aids (HAs) compared with unilateral, sequential, and simultaneous bilateral CI in Australian adults with bilateral severe to profound sensorineural hearing loss. Cost-utility analysis of secondary sources input to a Markov model. Australian health care perspective, lifetime horizon with costs and outcomes discounted 5% annually. Bilateral HAs as treatment for bilateral severe to profound sensorineural hearing loss compared with unilateral, sequential, and simultaneous bilateral CI. Incremental costs per quality adjusted life year (AUD/QALY). When compared with bilateral hearing aids the incremental cost-utility ratio for the CI treatment population was AUD11,160/QALY. The incremental cost-utility ratio was weighted according to the number of patients treated unilaterally, sequentially, and simultaneously, as these were mutually exclusive treatment options. No peer-reviewed articles have reported the incremental analysis of cochlear implantation in a continuum of care for surgically treated populations with bilateral severe to profound sensorineural hearing loss. Unilateral, sequential

  3. Cochlear implant outcomes in children with motor developmental delay.

    PubMed

    Amirsalari, Susan; Yousefi, Jaleh; Radfar, Shokofeh; Saburi, Amin; Tavallaie, Seyed Abbas; Hosseini, Mohammad Javad; Noohi, Sima; Hassan Alifard, Mahdieh; Ajallouyean, Mohammad

    2012-01-01

    Multiple handicapped children and children with syndromes and conditions resulting additional disabilities such as cerebral palsy, global developmental delay and autistic spectrum disorder, are now not routinely precluded from receiving a cochlear implant. The primary focus of this study was to determine the effect of cochlear implants on the speech perception and intelligibility of deaf children with and without motor development delay. In a cohort study, we compared cochlear implant outcomes in two groups of deaf children with or without motor developmental delay (MDD). Among 262 children with pre-lingual profound hearing loss, 28 (10%) had a motor delay based on Gross Motor Function Classification (GMFC). Children with severe motor delays (classification scale levels 4 and 5) and cognitive delays were excluded. All children completed the Categories of Auditory Perception Scales (CAP) and Speech Intelligibility Rating (SIR) prior to surgery and 24 months after the device was activated. The mean age for the study population was 4.09 ± 1.86 years. In all 262 patients the mean CAP score after surgery (5.38 ± 0.043) had a marked difference in comparison with the mean score before surgery (0.482 ± 0.018) (P=0.001). The mean CAP score after surgery for MDD children was 5.03, and was 5.77 for normal motor development children (NMD). The mean SIR score after surgery for MDD children was 2.53, and was 2.66 for NMD children. The final results of CAP and SIR did not have significant difference between NMD children versus MDD children (P>0.05). Regarding to the result, we concluded that children with hearing loss and concomitant MDD as an additional disabilities can benefit from cochlear implantation similar to those of NMD. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  4. Jervell and Lange-Nielsen syndrome in cochlear implanted patients: our experience and a review of literature.

    PubMed

    Eftekharian, Ali; Mahani, Mozhgan Hosseinerezai

    2015-09-01

    To share our experience in cochlear implanted patients with Jervell and Lange-Nielsen syndrome (JLNS), to review the literature results and to disclose precautions which have to be taken dealing with these patients. Electrocardiograms (ECG) of 503 children with congenital bilateral profound hearing loss which were cochlear implanted in cochlear implant center of a tertiary hospital were evaluated for long QT syndrome. Clinical reports of the patients with JLNS were evaluated and a review of literature performed. The prevalence of disease was 0.79% (four cases) in our center which is in the range of literature reports (0-2.6%). None of our patients had a history of syncopal attack. Two patients (50%) were born from parents with consanguineous marriage. Considering all precautions their cochlear implant surgeries were done uneventfully. A review of the literature has identified sixteen reports on cochlear implantation in a total of 38 children with JLNS. Similar to our cases none of the authors reported cardiac events during device switch-on. Nine available reports about the outcome of cochlear implantation in these patients indicated good auditory outcome. It is recommended that all congenitally deaf patients have an ECG taken as a part of the evaluation. As auditory stimuli is reported to be a specific trigger, it is prudent to activate the processor with continuous heart monitoring even though there is no reported cardiac event during device switch-on. Cochlear implantation can be performed relatively safely in these patients if necessary precautions have been taken appropriately and their auditory outcome is good. Triggers of the cardiac events should be avoided throughout their life. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  5. Spoken language skills and educational placement in Finnish children with cochlear implants.

    PubMed

    Lonka, Eila; Hasan, Marja; Komulainen, Erkki

    2011-01-01

    This study reports the demographics, and the auditory and spoken language development as well as educational settings, for a total of 164 Finnish children with cochlear implants. Two questionnaires were employed: the first, concerning day care and educational placement, was filled in by professionals for rehabilitation guidance, and the second, evaluating language development (categories of auditory performance, spoken language skills, and main mode of communication), by speech and language therapists in audiology departments. Nearly half of the children were enrolled in normal kindergartens and 43% of school-aged children in mainstream schools. Categories of auditory performance were observed to grow in relation to age at cochlear implantation (p < 0.001) as well as in relation to proportional hearing age (p < 0.001). The composite scores for language development moved to more diversified ones in relation to increasing age at cochlear implantation and proportional hearing age (p < 0.001). Children without additional disorders outperformed those with additional disorders. The results indicate that the most favorable age for cochlear implantation could be earlier than 2. Compared to other children, spoken language evaluation scores of those with additional disabilities were significantly lower; however, these children showed gradual improvements in their auditory perception and language scores. Copyright © 2011 S. Karger AG, Basel.

  6. Pharmacokinetic Properties of Adenosine Amine Congener in Cochlear Perilymph after Systemic Administration.

    PubMed

    Chang, Hao; Telang, Ravindra S; Sreebhavan, Sreevalsan; Tingle, Malcolm; Thorne, Peter R; Vlajkovic, Srdjan M

    2017-01-01

    Noise-induced hearing loss (NIHL) is a global health problem affecting over 5% of the population worldwide. We have shown previously that acute noise-induced cochlear injury can be ameliorated by administration of drugs acting on adenosine receptors in the inner ear, and a selective A 1 adenosine receptor agonist adenosine amine congener (ADAC) has emerged as a potentially effective treatment for cochlear injury and resulting hearing loss. This study investigated pharmacokinetic properties of ADAC in rat perilymph after systemic (intravenous) administration using a newly developed liquid chromatography-tandem mass spectrometry detection method. The method was developed and validated in accordance with the USA FDA guidelines including accuracy, precision, specificity, and linearity. Perilymph was sampled from the apical turn of the cochlea to prevent contamination with the cerebrospinal fluid. ADAC was detected in cochlear perilymph within two minutes following intravenous administration and remained in perilymph above its minimal effective concentration for at least two hours. The pharmacokinetic pattern of ADAC was significantly altered by exposure to noise, suggesting transient changes in permeability of the blood-labyrinth barrier and/or cochlear blood flow. This study supports ADAC development as a potential clinical otological treatment for acute sensorineural hearing loss caused by exposure to traumatic noise.

  7. Pharmacokinetic Properties of Adenosine Amine Congener in Cochlear Perilymph after Systemic Administration

    PubMed Central

    Sreebhavan, Sreevalsan; Thorne, Peter R.

    2017-01-01

    Noise-induced hearing loss (NIHL) is a global health problem affecting over 5% of the population worldwide. We have shown previously that acute noise-induced cochlear injury can be ameliorated by administration of drugs acting on adenosine receptors in the inner ear, and a selective A1 adenosine receptor agonist adenosine amine congener (ADAC) has emerged as a potentially effective treatment for cochlear injury and resulting hearing loss. This study investigated pharmacokinetic properties of ADAC in rat perilymph after systemic (intravenous) administration using a newly developed liquid chromatography-tandem mass spectrometry detection method. The method was developed and validated in accordance with the USA FDA guidelines including accuracy, precision, specificity, and linearity. Perilymph was sampled from the apical turn of the cochlea to prevent contamination with the cerebrospinal fluid. ADAC was detected in cochlear perilymph within two minutes following intravenous administration and remained in perilymph above its minimal effective concentration for at least two hours. The pharmacokinetic pattern of ADAC was significantly altered by exposure to noise, suggesting transient changes in permeability of the blood-labyrinth barrier and/or cochlear blood flow. This study supports ADAC development as a potential clinical otological treatment for acute sensorineural hearing loss caused by exposure to traumatic noise. PMID:28194422

  8. Ear asymmetries in middle-ear, cochlear, and brainstem responses in human infants

    PubMed Central

    Keefe, Douglas H.; Gorga, Michael P.; Jesteadt, Walt; Smith, Lynette M.

    2008-01-01

    In 2004, Sininger and Cone-Wesson examined asymmetries in the signal-to-noise ratio (SNR) of otoacoustic emissions (OAE) in infants, reporting that distortion-product (DP)OAE SNR was larger in the left ear, whereas transient-evoked (TE)OAE SNR was larger in the right. They proposed that cochlear and brainstem asymmetries facilitate development of brain-hemispheric specialization for sound processing. Similarly, in 2006 Sininger and Cone-Wesson described ear asymmetries mainly favoring the right ear in infant auditory brainstem responses (ABRs). The present study analyzed 2640 infant responses to further explore these effects. Ear differences in OAE SNR, signal, and noise were evaluated separately and across frequencies (1.5, 2, 3, and 4 kHz), and ABR asymmetries were compared with cochlear asymmetries. Analyses of ear-canal reflectance and admittance showed that asymmetries in middle-ear functioning did not explain cochlear and brainstem asymmetries. Current results are consistent with earlier studies showing right-ear dominance for TEOAE and ABR. Noise levels were higher in the right ear for OAEs and ABRs, causing ear asymmetries in SNR to differ from those in signal level. No left-ear dominance for DPOAE signal was observed. These results do not support a theory that ear asymmetries in cochlear processing mimic hemispheric brain specialization for auditory processing. PMID:18345839

  9. An easy access to retrieve dental implants displaced into the maxillary sinus: the bony window technique.

    PubMed

    Biglioli, Federico; Chiapasco, Matteo

    2014-12-01

    To present the authors' experience concerning the removal of dental implants displaced in the maxillary sinus via an intraoral approach consisting of the creation of a bony window pedicled to the maxillary sinus membrane. Thirty-six systemically healthy patients, presenting with oral implants displaced into the maxillary sinus, but with no signs of acute or chronic sinusitis, were consecutively treated between 2002 and 2012 via an intraoral approach with the bony window technique. Removal of oral implants from the maxillary sinus was achieved in all patients, and postoperative recovery was uneventful in all of them. Computed tomographies performed after surgery showed no signs of residual sinus infection in all patients and a complete ossification of the bony window margins. Twelve of the 36 treated patients were treated with a sinus grafting procedure 12-18 months after in the same areas previously treated with the bone lid technique. Seventeen implants were placed in the grafted areas 6-9 months later and, after a further waiting period needed for osseointegration, the treated patients were rehabilitated with implant-supported prostheses. The survival rate of implants was 100%, and no complications related to the sinuses and implants were recorded. Results from this study seem to demonstrate that the bony window technique is a safe and easy way to remove oral implants from the maxillary sinus under local anesthesia. The surgical access is hardly visible 6-12 months after surgery, and maxillary sinuses appeared free from residual pathology in all treated patients. Finally, this procedure allows a second-stage sinus grafting procedure via a lateral approach as in a previously untreated maxillary sinus, thus allowing an implant-supported prosthetic restoration. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Music recognition by Japanese children with cochlear implants.

    PubMed

    Nakata, Takayuki; Trehub, Sandra E; Mitani, Chisato; Kanda, Yukihiko; Shibasaki, Atsuko; Schellenberg, E Glenn

    2005-01-01

    Congenitally deaf Japanese children with cochlear implants were tested on their recognition of theme songs from television programs that they watched regularly. The children, who were 4-9 years of age, attempted to identify each song from a closed set of alternatives. Their song identification ability was examined in the context of the original commercial recordings (vocal plus instrumental), the original versions without the words (i.e., karaoke versions), and flute versions of the melody. The children succeeded in identifying the music only from the original versions, and their performance was related to their music listening habits. Children gave favorable appraisals of the music even when they were unable to recognize it. Further research is needed to find means of enhancing cochlear implants users' perception and appreciation of music.

  11. Parametric model of the scala tympani for haptic-rendered cochlear implantation.

    PubMed

    Todd, Catherine; Naghdy, Fazel

    2005-01-01

    A parametric model of the human scala tympani has been designed for use in a haptic-rendered computer simulation of cochlear implant surgery. It will be the first surgical simulator of this kind. A geometric model of the Scala Tympani has been derived from measured data for this purpose. The model is compared with two existing descriptions of the cochlear spiral. A first approximation of the basilar membrane is also produced. The structures are imported into a force-rendering software application for system development.

  12. Considerations for Pediatric Cochlear Implant Recipients With Unilateral or Asymmetric Hearing Loss: Assessment, Device Fitting, and Habilitation.

    PubMed

    Greaver, Laura; Eskridge, Hannah; Teagle, Holly F B

    2017-06-13

    The purpose of this clinical report is to present case studies of children who are nontraditional candidates for cochlear implantation because they have significant residual hearing in 1 ear and to describe outcomes and considerations for their audiological management and habilitation. Case information is presented for 5 children with profound hearing loss in 1 ear and normal or mild-to-moderate hearing loss in the opposite ear and who have undergone unilateral cochlear implantation. Pre- and postoperative assessments were performed per typical clinic routines with modifications described. Postimplant habilitation was customized for each recipient using a combination of traditional methods, newer technologies, and commercial materials. The 5 children included in this report are consistent users of their cochlear implants and demonstrate speech recognition in the implanted ear when isolated from the better hearing ear. Candidacy criteria for cochlear implantation are evolving. Children with single-sided deafness or asymmetric hearing loss who have traditionally not been considered candidates for cochlear implantation should be evaluated on a case-by-case basis. Audiological management of these recipients is not vastly different compared with children who are traditional cochlear implant recipients. Assessment and habilitation techniques must be modified to isolate the implanted ear to obtain accurate results and to provide meaningful therapeutic intervention.

  13. Sensitivity and specificity of cone beam computed tomography in thin bony structures in maxillofacial surgery – A clinical trial.

    PubMed

    Thönissen, P; Ermer, M A; Schmelzeisen, R; Gutwald, R; Metzger, M C; Bittermann, G

    2015-09-01

    Cone-Beam Computed Tomography (CBCT) has become widely used in dentistry and maxillofacial surgery. Accuracy, sensitivity and specificity of thin bony structures below 0.5 mm have been subject of some in vitro studies. This prospective in vivo study investigates the correlation between preoperative CBCT-imaging and intraoperative clinical examination of thin bony structures. We hereby present results from daily clinical routine. A total number of 80 sites in 64 patients has been examined to differentiate between preoperative 3D imaging and clinical measurements on cystic lesions in maxilla and mandible. Different CBCT-devices with a voxel size ranging from 0.08 mm to 0.4 mm were used. Overall-specificity found for detecting thin bony structures of the human jaw is 13.89%, overall sensitivity is 100%, positive predictive value (PPV) is 58.67% and negative predictive value (NPV) is 100%. Image quality is the key to make use of additional information CBCT provides and depends on spatial, temporal and contrast resolution. CBCT does not depict reliably thin bony structures of the jaw, even if high voxel resolution is used. In selected cases using high resolution protocols should be considered despite affecting the patient with higher doses of radiation. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  14. Rate and timing cues associated with the cochlear amplifier: level discrimination based on monaural cross-frequency coincidence detection.

    PubMed

    Heinz, M G; Colburn, H S; Carney, L H

    2001-10-01

    The perceptual significance of the cochlear amplifier was evaluated by predicting level-discrimination performance based on stochastic auditory-nerve (AN) activity. Performance was calculated for three models of processing: the optimal all-information processor (based on discharge times), the optimal rate-place processor (based on discharge counts), and a monaural coincidence-based processor that uses a non-optimal combination of rate and temporal information. An analytical AN model included compressive magnitude and level-dependent-phase responses associated with the cochlear amplifier, and high-, medium-, and low-spontaneous-rate (SR) fibers with characteristic frequencies (CFs) spanning the AN population. The relative contributions of nonlinear magnitude and nonlinear phase responses to level encoding were compared by using four versions of the model, which included and excluded the nonlinear gain and phase responses in all possible combinations. Nonlinear basilar-membrane (BM) phase responses are robustly encoded in near-CF AN fibers at low frequencies. Strongly compressive BM responses at high frequencies near CF interact with the high thresholds of low-SR AN fibers to produce large dynamic ranges. Coincidence performance based on a narrow range of AN CFs was robust across a wide dynamic range at both low and high frequencies, and matched human performance levels. Coincidence performance based on all CFs demonstrated the "near-miss" to Weber's law at low frequencies and the high-frequency "mid-level bump." Monaural coincidence detection is a physiologically realistic mechanism that is extremely general in that it can utilize AN information (average-rate, synchrony, and nonlinear-phase cues) from all SR groups.

  15. Cochlear implantation in children with Jervell and Lange-Nielsen syndrome - a cautionary tale.

    PubMed

    Broomfield, Stephen J; Bruce, Iain A; Henderson, Lise; Ramsden, Richard T; Green, Kevin M J

    2012-08-01

    Jervell and Lange-Nielsen (JLN) syndrome is a rare cause of congenital profound hearing loss associated with a prolonged QT interval on the electrocardiogram. Children presenting for cochlear implantation with this condition may be asymptomatic but are at risk of sudden death. SCREENING AND SUBSEQUENT: careful management is therefore required to ensure a successful outcome. We present our experience of cochlear implantation in children with JLN syndrome, including two who died unexpectedly, and suggest a protocol for management of such cases. Clinical presentation Four cases of cochlear implantation in JLN syndrome are described. None had any previous cardiological family history. Two were diagnosed pre-operatively but, despite appropriate management under a cardiologist, died from cardiac arrest; the first in the perioperative period following reimplantation for infection, and the second unrelated to his cochlear implant surgery. The other two patients were diagnosed only subsequent to their implantation and continue to use their implants successfully. These cases highlight the variation in presentation of JLN syndrome, and the spectrum of disease severity that exists. Our protocol stresses the importance of careful assessment and counselling of parents by an experienced implant team.

  16. Speech and language development in cognitively delayed children with cochlear implants.

    PubMed

    Holt, Rachael Frush; Kirk, Karen Iler

    2005-04-01

    The primary goals of this investigation were to examine the speech and language development of deaf children with cochlear implants and mild cognitive delay and to compare their gains with those of children with cochlear implants who do not have this additional impairment. We retrospectively examined the speech and language development of 69 children with pre-lingual deafness. The experimental group consisted of 19 children with cognitive delays and no other disabilities (mean age at implantation = 38 months). The control group consisted of 50 children who did not have cognitive delays or any other identified disability. The control group was stratified by primary communication mode: half used total communication (mean age at implantation = 32 months) and the other half used oral communication (mean age at implantation = 26 months). Children were tested on a variety of standard speech and language measures and one test of auditory skill development at 6-month intervals. The results from each test were collapsed from blocks of two consecutive 6-month intervals to calculate group mean scores before implantation and at 1-year intervals after implantation. The children with cognitive delays and those without such delays demonstrated significant improvement in their speech and language skills over time on every test administered. Children with cognitive delays had significantly lower scores than typically developing children on two of the three measures of receptive and expressive language and had significantly slower rates of auditory-only sentence recognition development. Finally, there were no significant group differences in auditory skill development based on parental reports or in auditory-only or multimodal word recognition. The results suggest that deaf children with mild cognitive impairments benefit from cochlear implantation. Specifically, improvements are evident in their ability to perceive speech and in their reception and use of language. However, it may

  17. Cortical Plasticity after Cochlear Implantation

    PubMed Central

    Petersen, B.; Gjedde, A.; Wallentin, M.; Vuust, P.

    2013-01-01

    The most dramatic progress in the restoration of hearing takes place in the first months after cochlear implantation. To map the brain activity underlying this process, we used positron emission tomography at three time points: within 14 days, three months, and six months after switch-on. Fifteen recently implanted adult implant recipients listened to running speech or speech-like noise in four sequential PET sessions at each milestone. CI listeners with postlingual hearing loss showed differential activation of left superior temporal gyrus during speech and speech-like stimuli, unlike CI listeners with prelingual hearing loss. Furthermore, Broca's area was activated as an effect of time, but only in CI listeners with postlingual hearing loss. The study demonstrates that adaptation to the cochlear implant is highly related to the history of hearing loss. Speech processing in patients whose hearing loss occurred after the acquisition of language involves brain areas associated with speech comprehension, which is not the case for patients whose hearing loss occurred before the acquisition of language. Finally, the findings confirm the key role of Broca's area in restoration of speech perception, but only in individuals in whom Broca's area has been active prior to the loss of hearing. PMID:24377050

  18. Cochlear compression: perceptual measures and implications for normal and impaired hearing.

    PubMed

    Oxenham, Andrew J; Bacon, Sid P

    2003-10-01

    This article provides a review of recent developments in our understanding of how cochlear nonlinearity affects sound perception and how a loss of the nonlinearity associated with cochlear hearing impairment changes the way sounds are perceived. The response of the healthy mammalian basilar membrane (BM) to sound is sharply tuned, highly nonlinear, and compressive. Damage to the outer hair cells (OHCs) results in changes to all three attributes: in the case of total OHC loss, the response of the BM becomes broadly tuned and linear. Many of the differences in auditory perception and performance between normal-hearing and hearing-impaired listeners can be explained in terms of these changes in BM response. Effects that can be accounted for in this way include poorer audiometric thresholds, loudness recruitment, reduced frequency selectivity, and changes in apparent temporal processing. All these effects can influence the ability of hearing-impaired listeners to perceive speech, especially in complex acoustic backgrounds. A number of behavioral methods have been proposed to estimate cochlear nonlinearity in individual listeners. By separating the effects of cochlear nonlinearity from other aspects of hearing impairment, such methods may contribute towards identifying the different physiological mechanisms responsible for hearing loss in individual patients. This in turn may lead to more accurate diagnoses and more effective hearing-aid fitting for individual patients. A remaining challenge is to devise a behavioral measure that is sufficiently accurate and efficient to be used in a clinical setting.

  19. Cochlear Modeling Using Time-Averaged Lagrangian" Method:. Comparison with VBM, PST, and ZC Measurements

    NASA Astrophysics Data System (ADS)

    Yoon, Y.; Kim, N.; Puria, S.; Steele, C. R.

    2009-02-01

    In this work, basilar membrane velocity (VBM), scala tympani intracochlear pressure (PST), and cochlear input impedances (Zc) for gerbil and chinchilla are implemented using a three-dimensional hydro-dynamic cochlear model using 1) time-averaged Lagrangian, 2) push-pull mechanism in active case, and 3) the complex anatomy of cochlear scalae by micro computed tomography (μCT) scanning and 3-D reconstructions of gerbil and chinchilla temporal bones. The objective of this work is to compare the calculations and the physiological measurements of gerbil and chinchilla cochlear such as VBM (Ren and Nuttall [1]), PST (Olson [2]), and ZC (Decraemer et al. [3], Songer and Rosowski [4], Ruggero et al. [5]) with present model. A WKB asymptotic method combined with Fourier series expansions is used to provide an efficient simulation. VBM and PST simulation results for the gerbil cochlea show good agreement both in the magnitude and the phase for the physiological measurements without larger phase excursion. ZC simulation from the gerbil and chinchilla model show reasonably good agreement with measurement.

  20. Cochlear Implantation in the Very Young Child: Issues Unique to the Under-1 Population

    PubMed Central

    Cosetti, Maura; Roland, J. Thomas

    2010-01-01

    Since the advent of cochlear implantation, candidacy criteria have slowly broadened to include increasingly younger patients. Spurred by evidence demonstrating both perioperative safety and significantly increased speech and language benefit with early auditory intervention, children younger than 12 months of age are now being successfully implanted at many centers. This review highlights the unique challenges involved in cochlear implantation in the very young child, specifically diagnosis and certainty of testing, anesthetic risk, surgical technique, intraoperative testing and postoperative programming, long-term safety, development of receptive and expressive language, and outcomes of speech perception. Overall, the current body of literature indicates that cochlear implantation prior to 1 year of age is both safe and efficacious. PMID:20483813

  1. Bony ankylosis of the facet joint of the cervical spine in rheumatoid arthritis: Its characteristics and relationship to the clinical findings.

    PubMed

    Iizuka, Haku; Iizuka, Yoichi; Okamura, Koichi; Yonemoto, Yukio; Mieda, Tokue; Takagishi, Kenji

    2017-09-01

    The purpose of this study was to clarify the characteristics of bony ankylosis of the facet joint of the cervical spine in rheumatoid arthritis (RA) patients who required cervical spine surgery, and its relationship to the clinical findings. Eighty consecutive RA patients with cervical spine disorder who received initial surgery were reviewed. The occurrence of bony ankylosis of the facet joint of the cervical spine was investigated using computed tomography (CT) before surgery. We also evaluated the severity of neurological symptoms and the plain wrist radiographs taken before surgery; furthermore, we evaluated each patient's medical history for total knee arthroplasty (TKA) or hip arthroplasty (THA). The preoperative CT imaging demonstrated bony ankylosis of the facet joint of the cervical spine in 45 facet levels of 19 cases (BA + group). In all patients, responsible instability or stenosis was demonstrated just caudal or on the cranial side of those bony ankylosis. Before surgery, the BA + group included significantly more patients showing severe cervical myelopathy (p < 0.05), and significantly more cases showing progressed ankylosis in the wrist joint bilaterally (p < 0.01). There were also significantly more patients who received two or more TKA or THA before the cervical spine surgery in the BA + group (p < 0.01). Bony ankylosis of the facet joint of the cervical spine may be a risk factor of instability or stenosis at the adjacent disc level and severe cervical myelopathy. Furthermore, its ankylosis was demonstrated in RA patients with severe destroyed joints.

  2. Allergenicity of bony and cartilaginous fish - molecular and immunological properties.

    PubMed

    Stephen, J N; Sharp, M F; Ruethers, T; Taki, A; Campbell, D E; Lopata, A L

    2017-03-01

    Allergy to bony fish is common and probably increasing world-wide. The major heat-stable pan-fish allergen, parvalbumin (PV), has been identified and characterized for numerous fish species. In contrast, there are very few reports of allergic reactions to cartilaginous fish despite widespread consumption. The molecular basis for this seemingly low clinical cross-reactivity between these two fish groups has not been elucidated. PV consists of two distinct protein lineages, α and β. The α-lineage of this protein is predominant in muscle tissue of cartilaginous fish (Chondrichthyes), while β-PV is abundant in muscle tissue of bony fish (Osteichthyes). The low incidence of allergic reactions to ingested rays and sharks is likely due to the lack of molecular similarity, resulting in reduced immunological cross-reactivity between the two PV lineages. Structurally and physiologically, both protein lineages are very similar; however, the amino acid homology is very low with 47-54%. Furthermore, PV from ancient fish species such as the coelacanth demonstrates 62% sequence homology to leopard shark α-PV and 70% to carp β-PV. This indicates the extent of conservation of the PV isoforms lineages across millennia. This review highlights prevalence data on fish allergy and sensitization to fish, and details the molecular diversity of the two protein lineages of the major fish allergen PV among different fish groups, emphasizing the immunological and clinical differences in allergenicity. © 2017 John Wiley & Sons Ltd.

  3. Cochlear implant magnet retrofit.

    PubMed

    Cohen, N L; Breda, S D; Hoffman, R A

    1988-06-01

    An implantable magnet is now available for patients who have received the standard Nucleus 22-channel cochlear implant and who are not able to wear the headband satisfactorily. This magnet is attached in piggy-back fashion to the previously implanted receiver/stimulator by means of a brief operation under local anesthesia. Two patients have received this magnet retrofit, and are now wearing the headset with greater comfort and satisfaction. It is felt that the availability of this magnet will increase patient compliance in regard to hours of implant usage.

  4. Long-Term Evolution of the Electrical Stimulation Levels for Cochlear Implant Patients

    PubMed Central

    Vargas, Jose Luis; Sainz, Manuel; Roldan, Cristina; de la Torre, Angel

    2012-01-01

    Objectives The stimulation levels programmed in cochlear implant systems are affected by an evolution since the first switch-on of the processor. This study was designed to evaluate the changes in stimulation levels over time and the relationship between post-implantation physiological changes and with the hearing experience provided by the continuous use of the cochlear implant. Methods Sixty-two patients, ranging in age from 4 to 68 years at the moment of implantation participated in this study. All subjects were implanted with the 12 channels COMBI 40+ cochlear implant at San Cecilio University Hospital, Granada, Spain. Hearing loss etiology and progression characteristics varied across subjects. Results The analyzed programming maps show that the stimulation levels suffer a fast evolution during the first weeks after the first switch-on of the processor. Then, the evolution becomes slower and the programming parameters tend to be stable at about 6 months after the first switch-on. The evolution of the stimulation levels implies an increment of the electrical dynamic range, which is increased from 15.4 to 20.7 dB and improves the intensity resolution. A significant increment of the sensitivity to acoustic stimuli is also observed. For some patients, we have also observed transitory changes in the electrode impedances associated to secretory otitis media, which cause important changes in the programming maps. Conclusion We have studied the long-term evolution of the stimulation levels in cochlear implant patients. Our results show the importance of systematic measurements of the electrode impedances before the revision of the programming map. This report also highlights that the evolution of the programming maps is an important factor to be considered in order to determine an adequate calendar fitting of the cochlear implant processor. PMID:23205223

  5. Simultaneous bilateral cochlear implantation in a five-month-old child with Usher syndrome.

    PubMed

    Alsanosi, A A

    2015-09-01

    To report a rare case of simultaneous bilateral cochlear implantation in a five-month-old child with Usher syndrome. Case report. A five-month-old boy with Usher syndrome and congenital profound bilateral deafness underwent simultaneous bilateral cochlear implantation. The decision to perform implantation in such a young child was based on his having a supportive family and the desire to foster his audiological development before his vision deteriorated. The subject experienced easily resolvable intra- and post-operative adverse events, and was first fitted with an externally worn audio processor four weeks after implantation. At 14 months of age, his audiological development was age-appropriate. Simultaneous bilateral cochlear implantation is possible, and even advisable, in children as young as five months old when performed by an experienced implantation team.

  6. Paediatric Cochlear Implantation in Patients with Waardenburg Syndrome

    PubMed Central

    van Nierop, Josephine W.I.; Snabel, Rebecca R.; Langereis, Margreet; Pennings, Ronald J.E.; Admiraal, Ronald J.C.; Mylanus, Emmanuel A.M.; Kunst, Henricus P.M.

    2016-01-01

    Objective To analyse the benefit of cochlear implantation in young deaf children with Waardenburg syndrome (WS) compared to a reference group of young deaf children without additional disabilities. Method A retrospective study was conducted on children with WS who underwent cochlear implantation at the age of 2 years or younger. The post-operative results for speech perception (phonetically balanced standard Dutch consonant-vocal-consonant word lists) and language comprehension (the Reynell Developmental Language Scales, RDLS), expressed as a language quotient (LQ), were compared between the WS group and the reference group by using multiple linear regression analysis. Results A total of 14 children were diagnosed with WS, and 6 of them had additional disabilities. The WS children were implanted at a mean age of 1.6 years and the 48 children of the reference group at a mean age of 1.3 years. The WS children had a mean phoneme score of 80% and a mean LQ of 0.74 at 3 years post-implantation, and these results were comparable to those of the reference group. Only the factor additional disabilities had a significant negative influence on auditory perception and language comprehension. Conclusions Children with WS performed similarly to the reference group in the present study, and these outcomes are in line with the previous literature. Although good counselling about additional disabilities concomitant to the syndrome is relevant, cochlear implantation is a good rehabilitation method for children with WS. PMID:27245679

  7. Paediatric Cochlear Implantation in Patients with Waardenburg Syndrome.

    PubMed

    van Nierop, Josephine W I; Snabel, Rebecca R; Langereis, Margreet; Pennings, Ronald J E; Admiraal, Ronald J C; Mylanus, Emmanuel A M; Kunst, Henricus P M

    2016-01-01

    To analyse the benefit of cochlear implantation in young deaf children with Waardenburg syndrome (WS) compared to a reference group of young deaf children without additional disabilities. A retrospective study was conducted on children with WS who underwent cochlear implantation at the age of 2 years or younger. The post-operative results for speech perception (phonetically balanced standard Dutch consonant-vocal-consonant word lists) and language comprehension (the Reynell Developmental Language Scales, RDLS), expressed as a language quotient (LQ), were compared between the WS group and the reference group by using multiple linear regression analysis. A total of 14 children were diagnosed with WS, and 6 of them had additional disabilities. The WS children were implanted at a mean age of 1.6 years and the 48 children of the reference group at a mean age of 1.3 years. The WS children had a mean phoneme score of 80% and a mean LQ of 0.74 at 3 years post-implantation, and these results were comparable to those of the reference group. Only the factor additional disabilities had a significant negative influence on auditory perception and language comprehension. Children with WS performed similarly to the reference group in the present study, and these outcomes are in line with the previous literature. Although good counselling about additional disabilities concomitant to the syndrome is relevant, cochlear implantation is a good rehabilitation method for children with WS. © 2016 S. Karger AG, Basel.

  8. Auditory Environment across the Life Span of Cochlear Implant Users: Insights from Data Logging

    ERIC Educational Resources Information Center

    Busch, Tobias; Vanpoucke, Filiep; van Wieringen, Astrid

    2017-01-01

    Purpose: We describe the natural auditory environment of people with cochlear implants (CIs), how it changes across the life span, and how it varies between individuals. Method: We performed a retrospective cross-sectional analysis of Cochlear Nucleus 6 CI sound-processor data logs. The logs were obtained from 1,501 people with CIs (ages 0-96…

  9. Searching for Cochlear Implant Information on the Internet Maze: Implications for Parents and Professionals

    ERIC Educational Resources Information Center

    Zaidman-Zait, Anat; Jamieson, Janet R.

    2004-01-01

    The present study has three purposes: (a) to determine who disseminates information on cochlear implants on the Web; (b) to describe a representative sample of Web sites that disseminate information on cochlear implants, with a focus on the content topics and their relevance to parents of deaf children; and (c) to discuss the practical issues of…

  10. A speech processing study using an acoustic model of a multiple-channel cochlear implant

    NASA Astrophysics Data System (ADS)

    Xu, Ying

    1998-10-01

    A cochlear implant is an electronic device designed to provide sound information for adults and children who have bilateral profound hearing loss. The task of representing speech signals as electrical stimuli is central to the design and performance of cochlear implants. Studies have shown that the current speech- processing strategies provide significant benefits to cochlear implant users. However, the evaluation and development of speech-processing strategies have been complicated by hardware limitations and large variability in user performance. To alleviate these problems, an acoustic model of a cochlear implant with the SPEAK strategy is implemented in this study, in which a set of acoustic stimuli whose psychophysical characteristics are as close as possible to those produced by a cochlear implant are presented on normal-hearing subjects. To test the effectiveness and feasibility of this acoustic model, a psychophysical experiment was conducted to match the performance of a normal-hearing listener using model- processed signals to that of a cochlear implant user. Good agreement was found between an implanted patient and an age-matched normal-hearing subject in a dynamic signal discrimination experiment, indicating that this acoustic model is a reasonably good approximation of a cochlear implant with the SPEAK strategy. The acoustic model was then used to examine the potential of the SPEAK strategy in terms of its temporal and frequency encoding of speech. It was hypothesized that better temporal and frequency encoding of speech can be accomplished by higher stimulation rates and a larger number of activated channels. Vowel and consonant recognition tests were conducted on normal-hearing subjects using speech tokens processed by the acoustic model, with different combinations of stimulation rate and number of activated channels. The results showed that vowel recognition was best at 600 pps and 8 activated channels, but further increases in stimulation rate and

  11. Is Perceptual Narrowing Too Narrow?

    ERIC Educational Resources Information Center

    Cashon, Cara H.; Denicola, Christopher A.

    2011-01-01

    There is a growing list of examples illustrating that infants are transitioning from having earlier abilities that appear more "universal," "broadly tuned," or "unconstrained" to having later abilities that appear more "specialized," "narrowly tuned," or "constrained." Perceptual narrowing, a well-known phenomenon related to face, speech, and…

  12. Amplification, Technology, and Cochlear Implants for Infants.

    ERIC Educational Resources Information Center

    Adam, Arlie J.

    1993-01-01

    Early amplification is crucial to efficient habilitation and development of oral communication skills in hearing-impaired infants. Initial evaluation and fitting of amplification is a joint effort by the audiologist, therapist, and parents, whether the child uses traditional hearing aids or cochlear implants, and should be supplemented by a…

  13. The early days of the multi channel cochlear implant: efforts and achievement in France.

    PubMed

    Chouard, C H

    2015-04-01

    On September 10th 2013, the clinical medical research Lasker award winners were rewarded for their work on multichannel cochlear implant. It has been my pleasure to see that such a major topic had caught the attention of the Members of the Jury for this prestigious award. That is why I accepted an invitation to participate in a special issue of Hearing Research devoted to the three winners. Here I highlight four scientific contributions made by the French team in late 1970s and early 1980s to modern multichannel cochlear implant development. 1) Chouard and MacLeod plotted an approximate frequency map of the whole length of the human cochlea, including its "hidden face" corresponding to speech frequencies. Moreover MacLeod suggested a sequential display of electrical stimulation as a function of each electrode, a precursor to today's electrodogram and interleaved stimulation. 2) Chouard performed total cochlear implantation in a deaf adult male with 8 electrically independent electrodes that were evenly distributed along the cochlea. 3) Chouard and MacLeod described in a patent detailed sound signal processing for a functional multichannel cochlear implant and reported speech discrimination without help of lip reading in some totally deafened patients. 4) Chouard experimentally demonstrated in the guinea pig the advantage of early cochlear implantation in treating profound neonatal deafness. This article is part of a Special Issue entitled . Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Two-photon microscopy allows imaging and characterization of cochlear microvasculature in vivo.

    PubMed

    Ihler, Friedrich; Bertlich, Mattis; Weiss, Bernhard; Dietzel, Steffen; Canis, Martin

    2015-01-01

    Impairment of cochlear blood flow has been discussed as factor in the pathophysiology of various inner ear disorders. However, the microscopic study of cochlear microcirculation is limited due to small scale and anatomical constraints. Here, two-photon fluorescence microscopy is applied to visualize cochlear microvessels. Guinea pigs were injected with Fluorescein isothiocyanate- or Texas red-dextrane as plasma marker. Intravital microscopy was performed in four animals and explanted cochleae from four animals were studied. The vascular architecture of the cochlea was visualized up to a depth of 90.0±22.7 μm. Imaging yielded a mean contrast-to-noise ratio (CNR) of 3.3±1.7. Mean diameter in vivo was 16.5±6.0 μm for arterioles and 8.0±2.4 μm for capillaries. In explanted cochleae, the diameter of radiating arterioles and capillaries was measured with 12.2±1.6 μm and 6.6±1.0 μm, respectively. The difference between capillaries and arterioles was statistically significant in both experimental setups (P<0.001 and P=0.022, two-way ANOVA). Measured vessel diameters in vivo and ex vivo were in agreement with published data. We conclude that two-photon fluorescence microscopy allows the investigation of cochlear microvessels and is potentially a valuable tool for inner ear research.

  15. Effect of age at cochlear implantation on auditory and speech development of children with auditory neuropathy spectrum disorder.

    PubMed

    Liu, Yuying; Dong, Ruijuan; Li, Yuling; Xu, Tianqiu; Li, Yongxin; Chen, Xueqing; Gong, Shusheng

    2014-12-01

    To evaluate the auditory and speech abilities in children with auditory neuropathy spectrum disorder (ANSD) after cochlear implantation (CI) and determine the role of age at implantation. Ten children participated in this retrospective case series study. All children had evidence of ANSD. All subjects had no cochlear nerve deficiency on magnetic resonance imaging and had used the cochlear implants for a period of 12-84 months. We divided our children into two groups: children who underwent implantation before 24 months of age and children who underwent implantation after 24 months of age. Their auditory and speech abilities were evaluated using the following: behavioral audiometry, the Categories of Auditory Performance (CAP), the Meaningful Auditory Integration Scale (MAIS), the Infant-Toddler Meaningful Auditory Integration Scale (IT-MAIS), the Standard-Chinese version of the Monosyllabic Lexical Neighborhood Test (LNT), the Multisyllabic Lexical Neighborhood Test (MLNT), the Speech Intelligibility Rating (SIR) and the Meaningful Use of Speech Scale (MUSS). All children showed progress in their auditory and language abilities. The 4-frequency average hearing level (HL) (500Hz, 1000Hz, 2000Hz and 4000Hz) of aided hearing thresholds ranged from 17.5 to 57.5dB HL. All children developed time-related auditory perception and speech skills. Scores of children with ANSD who received cochlear implants before 24 months tended to be better than those of children who received cochlear implants after 24 months. Seven children completed the Mandarin Lexical Neighborhood Test. Approximately half of the children showed improved open-set speech recognition. Cochlear implantation is helpful for children with ANSD and may be a good optional treatment for many ANSD children. In addition, children with ANSD fitted with cochlear implants before 24 months tended to acquire auditory and speech skills better than children fitted with cochlear implants after 24 months. Copyright © 2014

  16. Ethical conflicts in caring for patients with cochlear implants.

    PubMed

    McCormick, Thomas R

    2010-10-01

    Although the use of cochlear implants as a treatment designed to help deaf individuals hear has a relatively brief history, the use of this therapy has given rise to a number of ethical conflicts. This article identifies ethical conflicts in cochlear implantation therapy and shows how ethical principles that are commonly accepted in health care ethics may guide decision making in resolving these issues. Furthermore, clinicians are often confronted with particular cases in which ethical conflicts arise. A useful paradigm for the clinical context, the 4-box method, is offered as a means of organizing the facts of a "case" so that the important facts are considered, and a principled approach to decision making can be used in working toward a resolution.

  17. Otoacoustic Estimates of Cochlear Tuning: Testing Predictions in Macaque

    NASA Astrophysics Data System (ADS)

    Shera, Christopher A.; Bergevin, Christopher; Kalluri, Radha; Mc Laughlin, Myles; Michelet, Pascal; van der Heijden, Marcel; Joris, Philip X.

    2011-11-01

    Otoacoustic estimates of cochlear frequency selectivity suggest substantially sharper tuning in humans. However, the logic and methodology underlying these estimates remain untested by direct measurements in primates. We report measurements of frequency tuning in macaque monkeys, Old-World primates phylogenetically closer to humans than the small laboratory animals often taken as models of human hearing (e.g., cats, guinea pigs, and chinchillas). We find that measurements of tuning obtained directly from individual nerve fibers and indirectly using otoacoustic emissions both indicate that peripheral frequency selectivity in macaques is significantly sharper than in small laboratory animals, matching that inferred for humans at high frequencies. Our results validate the use of otoacoustic emissions for noninvasive measurement of cochlear tuning and corroborate the finding of sharper tuning in humans.

  18. The effect of spectral smearing on the identification of pure F0 intonation contours in vocoder simulations of cochlear implants.

    PubMed

    van de Velde, Daan J; Dritsakis, Giorgos; Frijns, Johan H M; van Heuven, Vincent J; Schiller, Niels O

    2015-03-01

    Performance of cochlear implant (CI) users on linguistic intonation recognition is poorer than that of normal-hearing listeners, due to the limited spectral detail provided by the implant. A higher spectral resolution is provided by narrow rather than by broad filter slopes. The corresponding effect of the filter slope on the identification of linguistic intonation conveyed by pitch movements alone was tested using vocoder simulations. Re-synthesized intonation variants of naturally produced phrases were processed by a 15-channel noise vocoder using a narrow (40 dB/octave) and a broad (20 dB/octave) filter slope. There were three different intonation patterns (rise/fall/rise-fall), differentiated purely by pitch and each associated to a different meaning. In both slope conditions as well as a condition with unprocessed stimuli, 24 normally hearing Dutch adults listened to a phrase, indicating which of two meanings was associated to it (i.e. a counterbalanced selection of two of the three contours). As expected, performance for the unprocessed stimuli was better than for the vocoded stimuli. No overall difference between the filter conditions was found. These results are taken to indicate that neither the narrow (20 dB/octave) nor the shallow (40 dB/octave) slope provide enough spectral detail to identify pure F(0) intonation contours. For users of a certain class of CIs, results could imply that their intonation perception would not benefit from steeper slopes. For them, perception of pitch movements in language requires more extreme filter slopes, more electrodes, and/or additional (phonetic/contextual) cues.

  19. The influence of cochlear implants on behaviour problems in deaf children.

    PubMed

    Jiménez-Romero, Ma Salud

    2015-01-01

    This study seeks to analyse the relationship between behaviour problems in deaf children and their auditory and communication development subsequent to cochlear implantation and to examine the incidence of these problems in comparison to their hearing peers. This study uses an ex post facto prospective design with a sample of 208 Spanish children, of whom 104 were deaf subjects with cochlear implants. The first objective assesses the relationships between behaviour problems, auditory integration, and social and communication skills in the group of deaf children. The second compares the frequency and intensity of behaviour problems of the group of deaf children with their hearing peers. The correlation analysis showed a significant association between the internal index of behaviour problems and auditory integration and communication skills, such that deaf children with greater auditory and communication development had no behaviour problems. When comparing behaviour problems in deaf children versus their hearing peers, behavioural disturbances are significantly more frequent in the former. According to these findings, cochlear implants may not guarantee adequate auditory and communicative development that would normalise the behaviour of deaf children.

  20. Deaf Education: The Impact of Cochlear Implantation?

    ERIC Educational Resources Information Center

    Archbold, Sue; Mayer, Connie

    2012-01-01

    This paper reviews the impact that cochlear implantation has had on the practice of deaf education in terms of educational placement, communication choices, and educational attainments. Although there is variation in outcome, more children with implants are going to mainstream schools, and using spoken language as their primary means of…

  1. Palaeobiology of Hyaenodon exiguus (Hyaenodonta, Mammalia) based on morphometric analysis of the bony labyrinth.

    PubMed

    Pfaff, Cathrin; Nagel, Doris; Gunnell, Gregg; Weber, Gerhard W; Kriwet, Jürgen; Morlo, Michael; Bastl, Katharina

    2017-02-01

    Species of the extinct genus Hyaenodon were among the largest carnivorous mammals from the Late Eocene through Early Miocene in North America, Europe and Asia. The origin, phylogeny and palaeobiology of Hyaenodonta are still ambiguous. Most previous studies focused on teeth and dental function in these highly adapted species, which might be influenced by convergent morphologies. The anatomy of the bony labyrinth in vertebrates is generally quite conservative and, additionally, was used in functional-morphological studies. This study provides the first anatomical description of the bony labyrinth of the extinct European species Hyaenodon exiguus in comparison to selected extant carnivoran taxa discussed from a functional-morphological perspective. Hyaenodon exiguus may have occupied a hyaena-like dietary niche with a semi-arboreal lifestyle, based on the relative height, width and length of the semicircular canals of the inner ear. However, this contradicts previous functional-morphological studies focusing on the diameter of the canals, which presumably represent the signal of locomotion mode. © 2016 Anatomical Society.

  2. Effects of nitric oxide synthase inhibitor on cochlear blood flow.

    PubMed

    Hoshijima, Hideaki; Makimoto, Kazuo; Noi, Osamu; Ohinata, Yoshimitsu; Takenaka, Hiroshi

    2002-09-01

    We observed in rats the changes in cochlear blood flow (CoBF) and cutaneous blood flow of the abdominal wall (AbBF) after the administration of the NO synthase inhibitor, N-nitro-L-arginine-methyl ester (L-NAME). Ten minutes after i.v. infusion of L-NAME (0.2, 1, 5, 10 mg/kg), L-arginine, which is a substrate of NO, was infused (100 mg/kg) i.v. Employing a laser Doppler flowmeter, the changes in blood flow were recorded from the basal turn of the right cochlea or the abdominal wall and blood pressure (BP) was recorded from the left femoral artery simultaneously. Vascular conductance (VC) was calculated from CoBF/mean BP (cochlear VC) or AbBF/mean BP (abdominal VC). The findings in rats generally agreed with those in guinea pigs [Brechtelsbauer et al., Hear. Res. 77 (1994) 38-42]. Intravenous infusion of L-NAME produced a dose-dependent depression of cochlear VC at 0.2 mg/kg (-18.9), 1 mg/kg (-37.9%), 5 mg/kg (-45.8%) and 10 mg/kg (-48.3%). AbBF also decreased after infusion of L-NAME (5 mg/kg) but to a lesser degree (-41.1% in VC) with no significance compared to CoBF (5 mg/kg). Infusion of L-arginine partially reversed the CoBF decrease caused by L-NAME. The group of 0.2 mg/kg infusion of L-NAME showed the largest degree of recovery with L-arginine, while the 10 mg/kg group showed the smallest. The decrease in AbBF did not recover substantially with L-arginine, the degree being less than that of each group in the CoBF experiment. It was suggested that the NO/soluble guanylate cyclase/cGMP system is more active in the cochlear microcirculation. With the round window (RW) application of 1% L-NAME (2 microl), cochlear VC was decreased by 21.6%, which was closest to that of the 0.2 mg/kg group of L-NAME i.v. infusion. The cochlear VC depression after local application of L-NAME did not show any recovery (-0.3%) by RW application of 5% L-arginine (2 microl) 25 min after L-NAME application; a slight gradual increase was observed when a higher concentration (20%) of L

  3. Cued Speech for Enhancing Speech Perception and First Language Development of Children With Cochlear Implants

    PubMed Central

    Leybaert, Jacqueline; LaSasso, Carol J.

    2010-01-01

    Nearly 300 million people worldwide have moderate to profound hearing loss. Hearing impairment, if not adequately managed, has strong socioeconomic and affective impact on individuals. Cochlear implants have become the most effective vehicle for helping profoundly deaf children and adults to understand spoken language, to be sensitive to environmental sounds, and, to some extent, to listen to music. The auditory information delivered by the cochlear implant remains non-optimal for speech perception because it delivers a spectrally degraded signal and lacks some of the fine temporal acoustic structure. In this article, we discuss research revealing the multimodal nature of speech perception in normally-hearing individuals, with important inter-subject variability in the weighting of auditory or visual information. We also discuss how audio-visual training, via Cued Speech, can improve speech perception in cochlear implantees, particularly in noisy contexts. Cued Speech is a system that makes use of visual information from speechreading combined with hand shapes positioned in different places around the face in order to deliver completely unambiguous information about the syllables and the phonemes of spoken language. We support our view that exposure to Cued Speech before or after the implantation could be important in the aural rehabilitation process of cochlear implantees. We describe five lines of research that are converging to support the view that Cued Speech can enhance speech perception in individuals with cochlear implants. PMID:20724357

  4. Breaking the sound barrier: exploring parents' decision-making process of cochlear implants for their children.

    PubMed

    Chang, Pamara F

    2017-08-01

    To understand the dynamic experiences of parents undergoing the decision-making process regarding cochlear implants for their child(ren). Thirty-three parents of d/Deaf children participated in semi-structured interviews. Interviews were digitally recorded, transcribed, and coded using iterative and thematic coding. The results from this study reveal four salient topics related to parents' decision-making process regarding cochlear implantation: 1) factors parents considered when making the decision to get the cochlear implant for their child (e.g., desire to acculturate child into one community), 2) the extent to which parents' communities influence their decision-making (e.g., norms), 3) information sources parents seek and value when decision-making (e.g., parents value other parent's experiences the most compared to medical or online sources), and 4) personal experiences with stigma affecting their decision to not get the cochlear implant for their child. This study provides insights into values and perspectives that can be utilized to improve informed decision-making, when making risky medical decisions with long-term implications. With thorough information provisions, delineation of addressing parents' concerns and encompassing all aspects of the decision (i.e., medical, social and cultural), health professional teams could reduce the uncertainty and anxiety for parents in this decision-making process for cochlear implantation. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Assessing the immunization status of pediatric cochlear implant recipients using a state-maintained immunization registry.

    PubMed

    Ou, Henry; Cleary, Patricia; Sie, Kathleen

    2010-10-01

    To demonstrate the use of a state-maintained database (CHILD Profile) to monitor immunization status of pediatric cochlear implant recipients, and to assess compliance with current vaccination recommendations for cochlear implant users managed at Seattle Children's Hospital. Cross-sectional study. Tertiary academic pediatric hospital. Subjects were 260 patients with cochlear implants managed at Seattle Children's Hospital between July 1, 1995, and May 1, 2008. Patients were stratified by age groups (0-2 years, 2-5 years, 5-10 years, > 10 years). Using a statewide children's immunization registry (CHILD Profile), subjects were assessed with regard to their immunization status for Haemophilus influenzae type B vaccination (HiB), 7-valent pneumococcal conjugate vaccination (PCV-7), and 23-valent pneumococcal polysaccharide vaccine (PPV-23). Two hundred twenty-five of 260 subjects (87%) were registered in CHILD Profile; 126 of 225 (56%) were up to date with CDC recommendations for patients with cochlear implants. PPV-23 was the vaccination most likely to be incomplete. Age was predictive of immunization status only with HiB vaccination. A statewide immunization registry can be used to monitor the immunization status of cochlear implant recipients. Subjects were significantly more likely to be incomplete for PPV-23 than for either PCV-7 or HiB vaccinations. Copyright © 2010 American Academy of Otolaryngology–Head and Neck Surgery Foundation. Published by Mosby, Inc. All rights reserved.

  6. Etanercept prevents decrease of cochlear blood flow dose-dependently caused by tumor necrosis factor alpha.

    PubMed

    Ihler, Friedrich; Sharaf, Kariem; Bertlich, Mattis; Strieth, Sebastian; Reichel, Christoph A; Berghaus, Alexander; Canis, Martin

    2013-07-01

    Tumor necrosis factor alpha (TNF-alpha) is a mediator of inflammation and microcirculation in the cochlea. This study aimed to quantify the effect of a local increase of TNF-alpha and study the effect of its interaction with etanercept on cochlear microcirculation. Cochlear lateral wall vessels were exposed surgically and assessed by intravital microscopy in guinea pigs in vivo. First, 24 animals were randomly distributed into 4 groups of 6 each. Exposed vessels were superfused repeatedly either with 1 of 3 different concentrations of TNF-alpha (5.0, 0.5, and 0.05 ng/mL) or with placebo (0.9% saline solution). Second, 12 animals were randomly distributed into 2 groups of 6 each. Vessels were pretreated with etanercept (1.0 microg/ mL) or placebo (0.9% saline solution), and then treated by repeated superfusion with TNF-alpha (5.0 ng/mL). TNF-alpha was shown to be effective in decreasing cochlear blood flow at a dose of 5.0 ng/mL (p < 0.01, analysis of variance on ranks). Lower concentrations or placebo treatment did not lead to significant changes. After pretreatment with etanercept, TNF-alpha at a dose of 5.0 ng/mL no longer led to a change in cochlear blood flow. The decreasing effect that TNF-alpha has on cochlear blood flow is dose-dependent. Etanercept abrogates this effect.

  7. Design of a Tool Integrating Force Sensing With Automated Insertion in Cochlear Implantation

    PubMed Central

    Schurzig, Daniel; Labadie, Robert F.; Hussong, Andreas; Rau, Thomas S.; Webster, Robert J.

    2012-01-01

    The quality of hearing restored to a deaf patient by a cochlear implant in hearing preservation cochlear implant surgery (and possibly also in routine cochlear implant surgery) is believed to depend on preserving delicate cochlear membranes while accurately inserting an electrode array deep into the spiral cochlea. Membrane rupture forces, and possibly, other indicators of suboptimal placement, are below the threshold detectable by human hands, motivating a force sensing insertion tool. Furthermore, recent studies have shown significant variability in manual insertion forces and velocities that may explain some instances of imperfect placement. Toward addressing this, an automated insertion tool was recently developed by Hussong et al. By following the same insertion tool concept, in this paper, we present mechanical enhancements that improve the surgeon’s interface with the device and make it smaller and lighter. We also present electomechanical design of new components enabling integrated force sensing. The tool is designed to be sufficiently compact and light that it can be mounted to a microstereotactic frame for accurate image-guided preinsertion positioning. The new integrated force sensing system is capable of resolving forces as small as 0.005 N, and we provide experimental illustration of using forces to detect errors in electrode insertion. PMID:23482414

  8. Effect of cochlear implantation on middle ear function: A three-month prospective study.

    PubMed

    Wasson, Joseph D; Campbell, Luke; Chambers, Scott; Hampson, Amy; Briggs, Robert J S; O'Leary, Stephen J

    2018-05-01

    To determine if cochlear implantation has a delayed effect on the middle ear conductive hearing mechanism by measuring laser Doppler vibrometry (LDV) of the tympanic membrane (TM) in both implanted and contralateral control ears preoperatively and 3 months postoperatively, and then comparing the relative change in LDV outcome measures between implanted and control ears. Prospective cohort study. Eleven preoperative adult unilateral cochlear implant recipients in previously unoperated ears with normal anatomy and aerated temporal bones were included in this study. The magnitude and phase angle of umbo velocity transfer function in response to air- conduction (AC) stimulus, and the magnitude of umbo velocity in response to bone- conduction (BC) stimulus were measured in the implant ear and the contralateral control ear preoperatively and 3 months postoperatively and compared. No significant changes in the magnitude or phase angle of TM velocity in response to either AC or BC stimulus were observed in the implanted ear relative to the contralateral control ear 3 months following cochlear implantation. From the results of LDV measurements, it can be said that cochlear implantation has no significant delayed effect on the middle ear conductive mechanism. 4. Laryngoscope, 128:1207-1212, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  9. Cochlear implant surgery in patients more than seventy-nine years old.

    PubMed

    Eshraghi, Adrien A; Rodriguez, Michael; Balkany, Thomas J; Telischi, Fred F; Angeli, Simon; Hodges, Annelle V; Adil, Eelam

    2009-06-01

    To evaluate the surgical complications, auditory performance, and hearing handicap following cochlear implantation in patients greater than 79 years of age. Retrospective trial, tertiary referral center. The study group was comprised of 21 patients implanted after 79 years of age from 1996 through 2006 with follow-ups past their 8th decade. Pre-op evaluation consisted of pure-tone audiometry and speech discrimination scores (Hearing in Noise Test and City University of New York sentence test). The results of these tests were compared to similar tests taken post-op. A validated hearing handicap questionnaire was used to evaluate the outcome. There were no permanent medical or surgical complications. However, two patients developed exacerbations of previous comorbid conditions (i.e., urinary retention and acute delirium). Implanted patients experienced a significant improvement in audiologic performance, post-op pure tone average, and post-op speech scores (P < .001). A majority of them were able to use the phone and reported that the cochlear implant was of great benefit to them. The post-op hearing handicap inventory for the elderly demonstrated a significant decrease of hearing handicap scores. This is the first study to focus on a patient group this advanced in age. With increasing life expectancy, we should begin to stratify risk versus benefit of cochlear implantation in this age group. Cochlear implantation improved audiologic performance and the quality of life in patients older than 79 years old. There were no permanent medical or surgical complications. Chronic pain and temporary vertigo were the most common complications reported in this elderly group. Laryngoscope, 2009.

  10. Persistence, Distribution, and Impact of Distinctly Segmented Microparticles on Cochlear Health following In Vivo Infusion3*

    PubMed Central

    Ross, Astin M.; Rahmani, Sahar; Prieskorn, Diane M.; Dishman, Acacia F; Miller, Josef M.; Lahann, Joerg; Altschuler, Richard A.

    2016-01-01

    Delivery of pharmaceuticals to the cochleae of patients with auditory dysfunction could potentially have many benefits from enhancing auditory nerve survival to protecting remaining sensory cells and their neuronal connections. Treatment would require platforms to enable drug delivery directly to the cochlea and increase the potential efficacy of intervention. Cochlear implant recipients are a specific patient subset that could benefit from local drug delivery as more candidates have residual hearing; and since residual hearing directly contributes to post-implantation hearing outcomes, it requires protection from implant insertion-induced trauma. This study assessed the feasibility of utilizing microparticles for drug delivery into cochlear fluids, testing persistence, distribution, biocompatibility, and drug release characteristics. To allow for delivery of multiple therapeutics, particles were composed of two distinct compartments; one containing polylactide-co-glycolide (PLGA), and one composed of acetal-modified dextran and PLGA. Following in vivo infusion, image analysis revealed microparticle persistence in the cochlea for at least 7 days post-infusion, primarily in the first and second turns. The majority of subjects maintained or had only slight elevation in auditory brainstem response thresholds at 7 days post-infusion compared to pre-infusion baselines. There was only minor to limited loss of cochlear hair cells and negligible immune response based on CD45+ immunolabling. When Piribedil-loaded microparticles were infused, Piribedil was detectable within the cochlear fluids at 7 days post-infusion. These results indicate that segmented microparticles are relatively inert, can persist, release their contents, and be functionally and biologically compatible with cochlear function and therefore are promising vehicles for cochlear drug delivery. PMID:26841263

  11. Intracochlear administration of steroids with a catheter during human cochlear implantation: a safety and feasibility study.

    PubMed

    Prenzler, Nils K; Salcher, Rolf; Timm, Max; Gaertner, Lutz; Lenarz, Thomas; Warnecke, Athanasia

    2018-05-14

    Suppression of foreign body reaction, improvement of electrode-nerve interaction, and preservation of residual hearing are essential research topics in cochlear implantation. Intracochlear pharmaco- or cell-based therapies can open new horizons in this field. Local drug delivery strategies are desirable as higher local concentrations of agents can be realized and side effects can be minimized compared to systemic administrations. When administered locally at accessible, basal parts of the cochlea, drugs reach apical regions later and in much lower concentrations due to poor diffusion patterns in cochlear fluids. Therefore, new devices are needed to warrant rapid distribution of agents into all parts of the cochlea. Five patients received a deep intracochlear injection of triamcinolone with a specifically designed cochlear catheter during cochlear implantation right before inserting a cochlear implant electrode. As a measure for formation of fibrous tissue around the electrode, electrical impedances were measured in the operation room and over 4 months thereafter. No adverse events were observed peri- and postoperatively. The handling of the device was easy. Severe damage to the microstructure of the cochlea was excluded as far as possible by cone beam computed tomography and vestibular testing. A delayed rise of the impedances was seen in the catheter group compared to controls over all regions of the cochlea. A statistical significance, however, was only obtained at the midregion of the cochlea. Consequently, the cochlear catheter is a safe and feasible device for local drug delivery of pharmaceutical agents into deeper regions of the cochlea.

  12. Educational, employment, and social participation of young adult graduates from the paediatric Southern Cochlear Implant Programme, New Zealand.

    PubMed

    Goh, Terence; Bird, Philip; Pearson, John; Mustard, Jill

    2016-01-01

    The purpose of this study is to observe the education and vocational achievements and social participation of cochlear implant recipients as they graduate from a paediatric cochlear implant programme and identify any significant associations that might exist. This study identified 56 patients from the Southern Cochlear Implant Programme (SCIP) who received cochlear implants before the age of 19 (paediatric) and are now over the age of 19 (adult). A questionnaire investigated their education, employment, and identity with the hearing and deaf communities. Also included were the satisfaction with life scale and Hearing Participation Scale (HPS). Subjects ranged in age from 19 to 32. Twenty-six patients responded to the questionnaire, including one non-user. Twenty identified strongly or very strongly with the hearing community. There was weak evidence of a linear association between strong identity with the hearing community and a higher HPS score. No other statistically significant associations were detected. Interestingly, 12 out of 26 participants found employment through family. Positive outcome trends in education and employment were seen in this study although no statistical significance was achieved. There is a strong bias for those who use their cochlear implants regularly, and there are no data available for those who do not use their cochlear implants for comparison as only one non-user completed the survey, despite efforts to include this group. This study shows that there is perceived benefit in implantation for patients who use it regularly but further research is needed with a more diverse group of cochlear implant recipients.

  13. Children's language development after cochlear implantation: a literature review.

    PubMed

    Monteiro, Clarice Gomes; Cordeiro, Ana Augusta de Andrade; Silva, Hilton Justino da; Queiroga, Bianca Arruda Manchester de

    2016-01-01

    review the literature for studies that describe the language development of children after they receive cochlear implants. Literature review on the PubMed, Web of Science, Scopus, and Science Direct databases, tracing the selection and critical analysis stages in the journals found and selected. We selected original articles looking at children with cochlear implants, which mentioned language development after surgery. Case studies, dissertations, books chapters, editorials, and original articles that did not mention aspects of oral communication development, perception of sounds and speech, and other stages of human development, in the title, abstract, or text, were excluded. A protocol was created for this study including the following points: author, year, location, sample, type of study, objectives, methods used, main results, and conclusion. 5,052 articles were found based on the search descriptors and free terms. Of this total, 3,414 were excluded due to the title, 1,245 due to the abstract, and 358 from reading the full text; we selected 35, of which 28 were repeated. In the end, seven articles were analyzed in this review. We conclude that cochlear implant users have slower linguistic and educational development than their peers with normal hearing - though they are better than conventional prostheses users - and they are able to match them over time. There is great variability in the test methodologies, thus reducing the effectiveness and reliability of the results found.

  14. Contribution of Family Environment to Pediatric Cochlear Implant Users' Speech and Language Outcomes: Some Preliminary Findings

    ERIC Educational Resources Information Center

    Holt, Rachael Frush; Beer, Jessica; Kronenberger, William G.; Pisoni, David B.; Lalonde, Kaylah

    2012-01-01

    Purpose: To evaluate the family environments of children with cochlear implants and to examine relationships between family environment and postimplant language development and executive function. Method: Forty-five families of children with cochlear implants completed a self-report family environment questionnaire (Family Environment Scale-Fourth…

  15. Environmental Sound Training in Cochlear Implant Users

    ERIC Educational Resources Information Center

    Shafiro, Valeriy; Sheft, Stanley; Kuvadia, Sejal; Gygi, Brian

    2015-01-01

    Purpose: The study investigated the effect of a short computer-based environmental sound training regimen on the perception of environmental sounds and speech in experienced cochlear implant (CI) patients. Method: Fourteen CI patients with the average of 5 years of CI experience participated. The protocol consisted of 2 pretests, 1 week apart,…

  16. Coupling Active Hair Bundle Mechanics, Fast Adaptation, and Somatic Motility in a Cochlear Model

    PubMed Central

    Meaud, Julien; Grosh, Karl

    2011-01-01

    One of the central questions in the biophysics of the mammalian cochlea is determining the contributions of the two active processes, prestin-based somatic motility and hair bundle (HB) motility, to cochlear amplification. HB force generation is linked to fast adaptation of the transduction current via a calcium-dependent process and somatic force generation is driven by the depolarization caused by the transduction current. In this article, we construct a global mechanical-electrical-acoustical mathematical model of the cochlea based on a three-dimensional fluid representation. The global cochlear model is coupled to linearizations of nonlinear somatic motility and HB activity as well as to the micromechanics of the passive structural and electrical elements of the cochlea. We find that the active HB force alone is not sufficient to power high frequency cochlear amplification. However, somatic motility can overcome resistor-capacitor filtering by the basolateral membrane and deliver sufficient mechanical energy for amplification at basal locations. The results suggest a new theory for high frequency active cochlear mechanics, in which fast adaptation controls the transduction channel sensitivity and thereby the magnitude of the energy delivered by somatic motility. PMID:21641302

  17. A novel perfusion-based method for cochlear implant electrode insertion.

    PubMed

    Kale, Sushrut; Cervantes, Vanessa M; Wu, Mailing R; Pisano, Dominic V; Sheth, Nakul; Olson, Elizabeth S

    2014-08-01

    A cochlear implant (CI) restores partial hearing to profoundly deaf individuals. CI electrodes are inserted manually in the cochlea and surgeons rely on tactile feedback from the implant to determine when to stop the insertion. This manual insertion method results in a large degree of variability in surgical outcomes and intra-cochlear trauma. Additionally, implants often span only the basal turn. In the present study we report on the development of a new method to assist CI electrode insertion. The design objectives are (1) an automated and standardized insertion technique across patients with (2) more apical insertion than is possible by the contemporary methods, while (3) minimizing insertion trauma. The method relies on a viscous fluid flow through the cochlea to carry the electrode array with it. A small cochleostomy (∼100-150 um in diameter) is made in scala vestibuli (SV) and the round window (RW) membrane is opened. A flow of diluted Sodium Hyaluronate (also known as Hyaluronic Acid, (HA)) is set up from the RW to the SV opening using a perfusion pump that sets up a unidirectional flow. Once the flow is established an implant is dropped into the ongoing flow. Here we present a proof-of-concept study where we used this technique to insert silicone implants all the way to the cochlear apex in rats and gerbils. In light-microscopic histology, the implantation occurred without cochlear trauma. To further assess the ototoxicity of the HA perfusion, we measured compound action potential (CAP) thresholds following the perfusion of HA, and found that the CAP thresholds were substantially elevated. Thus, at this point the method is promising, and requires further development to become clinically viable. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Acoustic Analysis of Speech of Cochlear Implantees and Its Implications

    PubMed Central

    Patadia, Rajesh; Govale, Prajakta; Rangasayee, R.; Kirtane, Milind

    2012-01-01

    Objectives Cochlear implantees have improved speech production skills compared with those using hearing aids, as reflected in their acoustic measures. When compared to normal hearing controls, implanted children had fronted vowel space and their /s/ and /∫/ noise frequencies overlapped. Acoustic analysis of speech provides an objective index of perceived differences in speech production which can be precursory in planning therapy. The objective of this study was to compare acoustic characteristics of speech in cochlear implantees with those of normal hearing age matched peers to understand implications. Methods Group 1 consisted of 15 children with prelingual bilateral severe-profound hearing loss (age, 5-11 years; implanted between 4-10 years). Prior to an implant behind the ear, hearing aids were used; prior & post implantation subjects received at least 1 year of aural intervention. Group 2 consisted of 15 normal hearing age matched peers. Sustained productions of vowels and words with selected consonants were recorded. Using Praat software for acoustic analysis, digitized speech tokens were measured for F1, F2, and F3 of vowels; centre frequency (Hz) and energy concentration (dB) in burst; voice onset time (VOT in ms) for stops; centre frequency (Hz) of noise in /s/; rise time (ms) for affricates. A t-test was used to find significant differences between groups. Results Significant differences were found in VOT for /b/, F1 and F2 of /e/, and F3 of /u/. No significant differences were found for centre frequency of burst, energy concentration for stops, centre frequency of noise in /s/, or rise time for affricates. These findings suggest that auditory feedback provided by cochlear implants enable subjects to monitor production of speech sounds. Conclusion Acoustic analysis of speech is an essential method for discerning characteristics which have or have not been improved by cochlear implantation and thus for planning intervention. PMID:22701768

  19. SU-E-J-33: Comparison Between Soft Tissue Alignment and Bony Alignment for Pancreatic Cancer Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Suh, Y; Crane, C; Krishnan, S

    Purpose An IGRT modality for pancreatic cancer treatment with dose escalation at our institution is in-room daily CT imaging. The purpose of this study is to assess the difference between soft tissue alignment and bony alignment for pancreatic tumor localization. Methods Eighteen patients with pancreatic tumors who underwent IMRT treatment with an inspiration breath-hold technique between July 2012 and February 2015 are included in this study. Prior to each treatment, a CT scan was acquired. The CT image guidance started with auto-alignment to either the bony anatomy (vertebral bodies) or fiducials (for the six patients with the stent in/near themore » tumor) and then, when necessary, manual adjustments were made based on soft tissue alignment using clinical software (CT-Assisted Targeting system). The difference between soft tissue alignment and bony/fiducial alignment was evaluated. Results Of all 380 treatments, manual adjustment was made in 225 treatments, ranging from 11% (3 treatments out of 28) to 96% (27 treatments out of 28) per patient. The mean of the difference between soft tissue alignment and bony/fiducial alignment per patient ranged from −3.6 to 0.3 mm, −1.5 to 2.8 mm, and −3.3 to 3.4 mm in the AP, SI, and RL directions, respectively. The maximum difference over all treatments was −9.5, −14.6, and −14.6 mm in the AP, SI, and RL directions, respectively. Conclusion About 60% of the time, manual adjustment based on soft tissue alignment was required. The extent of manual adjustment was usually small but varied significantly from patient to patient. The ultimate goal of the IGRT modality using daily CT imaging is not to fully cover the target but to spare organs-at-risk as much as possible to avoid them moving into higher dose gradients than accepted in the treatment plan. To this end, manual adjustment based on soft tissue alignment is critically important.« less

  20. Effects of Cerebral Blood Flow and Vessel Conditions on Speech Recognition in Patients With Postlingual Adult Cochlear Implant: Predictable Factors for the Efficacy of Cochlear Implant.

    PubMed

    Ishino, Takashi; Ragaee, Mahmoud Ali; Maruhashi, Tatsuya; Kajikawa, Masato; Higashi, Yukihito; Sonoyama, Toru; Takeno, Sachio; Hirakawa, Katsuhiro

    Cochlear implantation (CI) has been the most successful procedure for restoring hearing in a patient with severe and profound hearing loss. However, possibly owing to the variable brain functions of each patient, its performance and the associated patient satisfaction are widely variable. The authors hypothesize that peripheral and cerebral circulation can be assessed by noninvasive and globally available methods, yielding superior presurgical predictive factors of the performance of CI in adult patients with postlingual hearing loss who are scheduled to undergo CI. Twenty-two adult patients with cochlear implants for postlingual hearing loss were evaluated using Doppler sonography measurement of the cervical arteries (reflecting cerebral blood flow), flow-mediated dilation (FMD; reflecting the condition of cerebral arteries), and their pre-/post-CI best score on a monosyllabic discrimination test (pre-/post-CI best monosyllabic discrimination [BMD] score). Correlations between post-CI BMD score and the other factors were examined using univariate analysis and stepwise multiple linear regression analysis. The prediction factors were calculated by examining the receiver-operating characteristic curve between post-CI BMD score and the significantly positively correlated factors. Age and duration of deafness had a moderately negative correlation. The mean velocity of the internal carotid arteries and FMD had a moderate-to-strong positive correlation with the post-CI BMD score in univariate analysis. Stepwise multiple linear regression analysis revealed that only FMD was significantly positively correlated with post-CI BMD score. Analysis of the receiver-operating characteristic curve showed that a FMD cutoff score of 1.8 significantly predicted post-CI BMD score. These data suggest that FMD is a convenient, noninvasive, and widely available tool for predicting the efficacy of cochlear implants. An FMD cutoff score of 1.8 could be a good index for determining whether

  1. Neurotrophins differentially stimulate the growth of cochlear neurites on collagen surfaces and in gels☆

    PubMed Central

    Xie, Joanna; Pak, Kwang; Evans, Amaretta; Kamgar-Parsi, Andy; Fausti, Stephen; Mullen, Lina; Ryan, Allen Frederic

    2013-01-01

    The electrodes of a cochlear implant are located far from the surviving neurons of the spiral ganglion, which results in decreased precision of neural activation compared to the normal ear. If the neurons could be induced to extend neurites toward the implant, it might be possible to stimulate more discrete subpopulations of neurons, and to increase the resolution of the device. However, a major barrier to neurite growth toward a cochlear implant is the fluid filling the scala tympani, which separates the neurons from the electrodes. The goal of this study was to evaluate the growth of cochlear neurites in three-dimensional extracellular matrix molecule gels, and to increase biocompatibility by using fibroblasts stably transfected to produce neurotrophin-3 and brain-derived neurotrophic factor. Spiral ganglion explants from neonatal rats were evaluated in cultures. They were exposed to soluble neurotrophins, cells transfected to secrete neurotrophins, and/or collagen gels. We found that cochlear neurites grew readily on collagen surfaces and in three-dimensional collagen gels. Co-culture with cells producing neurotrophin-3 resulted in increased numbers of neurites, and neurites that were longer than when explants were cultured with control fibroblasts stably transfected with green fluorescent protein. Brain-derived neurotrophic factor-producing cells resulted in a more dramatic increase in the number of neurites, but there was no significant effect on neurite length. It is suggested that extracellular matrix molecule gels and cells transfected to produce neurotrophins offer an opportunity to attract spiral ganglion neurites toward a cochlear implant. PMID:24459465

  2. Auditory steady-state response in cochlear implant patients.

    PubMed

    Torres-Fortuny, Alejandro; Arnaiz-Marquez, Isabel; Hernández-Pérez, Heivet; Eimil-Suárez, Eduardo

    2018-03-19

    Auditory steady state responses to continuous amplitude modulated tones at rates between 70 and 110Hz, have been proposed as a feasible alternative to objective frequency specific audiometry in cochlear implant subjects. The aim of the present study is to obtain physiological thresholds by means of auditory steady-state response in cochlear implant patients (Clarion HiRes 90K), with acoustic stimulation, on free field conditions and to verify its biological origin. 11 subjects comprised the sample. Four amplitude modulated tones of 500, 1000, 2000 and 4000Hz were used as stimuli, using the multiple frequency technique. The recording of auditory steady-state response was also recorded at 0dB HL of intensity, non-specific stimulus and using a masking technique. The study enabled the electrophysiological thresholds to be obtained for each subject of the explored sample. There were no auditory steady-state responses at either 0dB or non-specific stimulus recordings. It was possible to obtain the masking thresholds. A difference was identified between behavioral and electrophysiological thresholds of -6±16, -2±13, 0±22 and -8±18dB at frequencies of 500, 1000, 2000 and 4000Hz respectively. The auditory steady state response seems to be a suitable technique to evaluate the hearing threshold in cochlear implant subjects. Copyright © 2018 Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. Publicado por Elsevier España, S.L.U. All rights reserved.

  3. A Mixed Mode Cochlear Amplifier Including Neural Feedback

    NASA Astrophysics Data System (ADS)

    Flax, Matthew R.; Holmes, W. Harvey

    2011-11-01

    The mixed mode cochlear amplifier (MMCA) model is derived from the physiology of the cochlea. It is comprised of three main elements of the peripheral hearing system: the cochlear mechanics, hair cell motility, and neurophysiology. This model expresses both active compression wave and active traveling wave modes of operation. The inclusion of a neural loop with a time delay, and a new paradigm for the mechanical response of the outer hair cells, are believed to be unique features of the MMCA. These elements combine to form an active feedback loop to constitute the cochlear amplifier, whose input is a passive traveling wave vibration. The result is a cycle-by-cycle amplifier with nonlinear response. This system can assume an infinite number of different operating states. The stable state and the first few amplitude-limited unstable (Hopf-bifurcated) states are significant in describing the operation of the peripheral hearing system. A hierarchy of models can be constructed from this concept, depending on the amount of detail included. The simplest model of the MMCA is a nonlinear delay line resonator. It was found that even this simple MMCA version can explain a large number of hearing phenomena, at least qualitatively. This paper concentrates on explaining the fractional octave shift from the living to postmortem response in terms of the new model. Other mechanical, hair cell and neurological phenomena can also be accounted for by the MMCA, including two-tone suppression behavior, distortion product responses, otoacoustic emissions and neural spontaneous rates.

  4. Ototoxicity of paclitaxel in rat cochlear organotypic cultures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dong, Yang; Center for Hearing and Deafness, University at Buffalo, NY 14214; Ding, Dalian

    Paclitaxel (taxol) is a widely used antineoplastic drug employed alone or in combination to treat many forms of cancer. Paclitaxel blocks microtubule depolymerization thereby stabilizing microtubules and suppressing cell proliferation and other cellular processes. Previous reports indicate that paclitaxel can cause mild to moderate sensorineural hearing loss and some histopathologic changes in the mouse cochlea; however, damage to the neurons and the underlying cell death mechanisms are poorly understood. To evaluate the ototoxicity of paclitaxel in more detail, cochlear organotypic cultures from postnatal day 3 rats were treated with paclitaxel for 24 or 48 h with doses ranging from 1more » to 30 μM. No obvious histopathologies were observed after 24 h treatment with any of the paclitaxel doses employed, but with 48 h treatment, paclitaxel damaged cochlear hair cells in a dose-dependent manner and also damaged auditory nerve fibers and spiral ganglion neurons (SGN) near the base of the cochlea. TUNEL labeling was negative in the organ of Corti, but positive in SGN with karyorrhexis 48 h after 30 μM paclitaxel treatment. In addition, caspase-6, caspase-8 and caspase-9 labeling was present in SGN treated with 30 μM paclitaxel for 48 h. These results suggest that caspase-dependent apoptotic pathways are involved in paclitaxel-induced damage of SGN, but not hair cells in cochlea. - Highlights: • Paclitaxel was toxic to cochlear hair cells and spiral ganglion neurons. • Paclitaxel-induced spiral ganglion degeneration was apoptotic. • Paclitaxel activated caspase-6, -8 and -8 in spiral ganglion neurons.« less

  5. "Sub Specie Boni": The Comfort Zone of Self-Belief--A Dimension in Counseling Offenders.

    ERIC Educational Resources Information Center

    Church, James Lee

    1996-01-01

    Claims that self-defeating behavior is a rational attempt to satisfy early, introjected messages about the type of person one is, arising from a desire for things perceived as good--sub specie boni. Examines the notion of the comfort zone, toxic shame, and therapists' responsibility to nourish acceptable joy. (RJM)

  6. Auditory Learning in Children with Cochlear Implants

    ERIC Educational Resources Information Center

    Mishra, Srikanta K.; Boddupally, Shiva P.; Rayapati, Deeksha

    2015-01-01

    Purpose: The purpose of this study was to examine and characterize the training-induced changes in speech-in-noise perception in children with congenital deafness who have cochlear implants (CIs). Method: Twenty-seven children with congenital deafness who have CIs were studied. Eleven children with CIs were trained on a speech-in-noise task,…

  7. Word Learning in Children following Cochlear Implantation

    ERIC Educational Resources Information Center

    Houston, Derek M.; Carter, Allyson K.; Pisoni, David B.; Kirk, Karen Iler; Ying, Elizabeth A.

    2005-01-01

    An experimental procedure was developed to investigate word-learning skills of children who use cochlear implants (CIs). Using interactive play scenarios, 2- to 5-year olds were presented with sets of objects (Beanie Baby stuffed animals) and words for their names that corresponded to salient perceptual attributes (e.g., "horns" for a goat). Their…

  8. A preliminary study looking at parental emotions following cochlear implantation.

    PubMed

    Anagnostou, Flora; Graham, John; Crocker, Susan

    2007-06-01

    This preliminary research investigated the emotions of parents with cochlear implanted children. The object for the research was first to compare four emotions engendered in parents of deaf children before and after cochlear implantation. Second, to monitor changes in these emotions during a period of up to four years after implantation. Third, to see whether any of the emotions studied was significantly more prominent than the others, and fifth to identify any differences in emotions that were related to the gender of parents. A self-report questionnaire was given to 112 participants of whom 53 replied. There were equal groups of parents in two categories, those with children up to two years after implantation, and those two to four years after implantation. The responses were interpreted using parametric statistics. The results highlight that grief is the strongest emotional condition that parents experience before and up to two years after implantation, alongside family adjustments. Parents of the up to two years after implantation group generally have stronger feelings and are less satisfied than parents in the over two years implanted group. Finally, fathers use denial more than mothers. Considerations for future research and implications for paediatric cochlear implant teams will be discussed. 2007 John Wiley & Sons, Ltd.

  9. Surfers ankle: a bony spur of the talar neck

    PubMed Central

    Brooks, Francis Michael; Williams, Paul; Carpenter, E C

    2009-01-01

    A 27-year-old competitive surfer presented with a history of a painful right ankle. He was able to recall an injury to his right ankle 4–5 years previously, sustained while surfing. The mechanism described was that he had dropped a considerable height during take-off, sustaining an impact injury from the board. He recalled immediate pain and swelling followed by 2–3 weeks of pain and a limp; he continued to surf, albeit with difficulty, despite this. Investigations found him to have a bony spur on the anterolateral part of the talus. This case shows how this injury is similar to those observed in other sports. PMID:21709829

  10. Translabyrinthine vestibular neurectomy and simultaneous cochlear implant for Ménière's disease.

    PubMed

    Canzi, Pietro; Manfrin, Marco; Perotti, Marco; Aprile, Federico; Quaglieri, Silvia; Rebecchi, Elisabetta; Locatelli, Giulia; Benazzo, Marco

    2017-01-01

    Surgical management of Ménière's disease (MD) is recommended in case of medical and intratympanic treatment failures. Translabyrinthine vestibular nerve section has been considered the gold standard for denervation procedures in order to control vertigo attacks, although at the cost of sacrificing residual hearing. To the best of our knowledge, no work has been published with regard to a group of patients submitted to translabyrinthine vestibular neurectomy and simultaneous cochlear implant for MD. The aim of the present study was to assess the effectiveness of translabyrinthine vestibular nerve section and simultaneous cochlear implant in a prospective study. All adult patients (over 18 years of age) with a diagnosis of intractable unilateral definite MD and useless residual hearing function were enrolled after medical and intratympanic treatment failures. Pre- and postoperative otoneurological evaluation concerned: frequency of vertigo attacks, head impulse test and caloric testing, pure tone average and speech perception audiometry in quiet conditions, tinnitus handicap inventory test, functional level scale and rate of vertigo control, dizziness handicap inventory test, and MD patient-oriented severity index. At least 6 months of follow-up were needed to be enrolled in the study. Four patients were included in the study. Translabyrinthine vestibular nerve section and simultaneous cochlear implant seemed to considerably improve the disabling effects of MD, achieving a good control of vestibular symptoms (mean pre/postoperative vertigo attacks per month: 16.5/0), resolving hearing loss (mean pre/postoperative pure tone average in the affected ear: 86.2/32.5 dB), improving the tinnitus (mean pre/postoperative tinnitus handicap inventory test: 77.2/6), and finally increasing the overall quality-of-life parameters. In our preliminary report, translabyrinthine vestibular nerve section and simultaneous cochlear implant showed encouraging results in order to

  11. The effect of topically administered latanoprost on the cochlear blood flow and hearing.

    PubMed

    Jang, Chul Ho; Cho, Yong Beom; Choi, Cheol Hee; Um, Jae-Young; Wang, Pa-Chun; Pak, Sok Cheon

    2013-06-01

    The application of intratympanic latanoprost (PGF2α analog) has been recently used to alleviate vertigo, disequilibrium and to improve hearing in Meniere's disease patients. However, there is no known report on the effect of topically applied latanoprost on hearing and cochlear hemodynamic parameters including cochlear blood flow (CBF) and vascular conductance. Our goal was to assess the influence of topically applied latanoprost on cochlear blood flow (CBF) and hearing. Twenty male Sprague-Dawley rats were randomly divided into the group A, 50 μl of latanoprost (1 ml containing 50 μg, n=10) and group B, 100 μl (1 ml containing 50 μg, n=10). Topical application of latanoprost was performed at the right side, and the left side was applied with phosphate buffered saline (PBS) as a negative control. Five rats at each group were used to measure cochlear blood flow (CBF). And the others at each group were used for hearing test by auditory brainstem response (ABR). After physiological examination, bullas were extracted. The changes of cochlear hair cells were observed by performing the field emission-scanning electron microscopy (FE-SEM). The CBF of both groups was found to be decreased compared to the PBS applied left side. Significant decrement of CBF was observed in group B compared to the group A. Significant elevation of hearing threshold at high frequencies was observed in both groups compared to the PBS applied group. However, inner and outer hair cells were intact. Topically administered latanoprost decreased the CBF and impaired hearing. Based on our findings, additional studies are required to evaluate the side effects of intratympanic latanoprost before its use in clinical practice. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  12. Bilateral and Unilateral Cochlear Implant Users Compared on Speech Perception in Noise

    PubMed Central

    Dunn, Camille C.; Noble, William; Tyler, Richard S.; Kordus, Monika; Gantz, Bruce J.; Ji, Haihong

    2009-01-01

    Objective Compare speech performance in noise with matched bilateral (CICI) and unilateral (CI-Only) cochlear implant users. Design Thirty CICI and 30 CI-Only subjects were tested on a battery of speech perception tests in noise that utilize an 8-loudspeaker array. Results On average, CICI subject's performance with speech in noise was significantly better than the CI-Only subjects. Conclusion The CICI group showed significantly better performance on speech perception in noise compared to the CI-Only subjects, supporting the hypothesis that bilateral cochlear implantation is more beneficial than unilateral implantation. PMID:19858720

  13. Bilateral and unilateral cochlear implant users compared on speech perception in noise.

    PubMed

    Dunn, Camille C; Noble, William; Tyler, Richard S; Kordus, Monika; Gantz, Bruce J; Ji, Haihong

    2010-04-01

    Compare speech performance in noise with matched bilateral cochlear implant (CICI) and unilateral cochlear implant (CI only) users. Thirty CICI and 30 CI-only subjects were tested on a battery of speech perception tests in noise that use an eight-loudspeaker array. On average, CICI subject's performance with speech in noise was significantly better than the CI-only subjects. The CICI group showed significantly better performance on speech perception in noise compared with the CI-only subjects, supporting the hypothesis that CICI is more beneficial than CI only.

  14. “Soft that molds the hard:” Geometric morphometry of lateral atlantoaxial joints focusing on the role of cartilage in changing the contour of bony articular surfaces

    PubMed Central

    Prasad, Prashant Kumar; Salunke, Pravin; Sahni, Daisy; Kalra, Parveen

    2017-01-01

    Purpose: The existing literature on lateral atlantoaxial joints is predominantly on bony facets and is unable to explain various C1-2 motions observed. Geometric morphometry of facets would help us in understanding the role of cartilages in C1-2 biomechanics/kinematics. Objective: Anthropometric measurements (bone and cartilage) of the atlantoaxial joint and to assess the role of cartilages in joint biomechanics. Materials and Methods: The authors studied 10 cadaveric atlantoaxial lateral joints with the articular cartilage in situ and after removing it, using three-dimensional laser scanner. The data were compared using geometric morphometry with emphasis on surface contours of articulating surfaces. Results: The bony inferior articular facet of atlas is concave in both sagittal and coronal plane. The bony superior articular facet of axis is convex in sagittal plane and is concave (laterally) and convex medially in the coronal plane. The bony articulating surfaces were nonconcordant. The articular cartilages of both C1 and C2 are biconvex in both planes and are thicker than the concavities of bony articulating surfaces. Conclusion: The biconvex structure of cartilage converts the surface morphology of C1-C2 bony facets from concave on concavo-convex to convex on convex. This reduces the contact point making the six degrees of freedom of motion possible and also makes the joint gyroscopic. PMID:29403249

  15. Factors influencing the efficacy of round window dexamethasone protection of residual hearing post-cochlear implant surgery.

    PubMed

    Chang, Andrew; Eastwood, Hayden; Sly, David; James, David; Richardson, Rachael; O'Leary, Stephen

    2009-09-01

    To protect hearing in an experimental model of cochlear implantation by the application of dexamethasone to the round window prior to surgery. The present study examined the dosage and timing relationships required to optimise the hearing protection. Dexamethasone or saline (control) was absorbed into a pledget of the carboxymethylcellulose and hyaluronic acid and applied to the round window of the guinea pig prior to cochlear implantation. The treatment groups were 2% w/v dexamethasone for 30, 60 and 120min; 20% dexamethasone applied for 30min. Auditory sensitivity was determined pre-operatively, and at 1 week after surgery, with pure-tone auditory brainstem response audiometry (2-32kHz). Cochlear implantation was performed via a cochleostomy drilled into the basal turn of the cochlea, into which a miniature cochlear implant dummy electrode was inserted using soft-surgery techniques. ABR thresholds were elevated after cochlear implantation, maximally at 32kHz and to a lesser extent at lower frequencies. Thresholds were less elevated after dexamethasone treatment, and the hearing protection improved when 2% dexamethasone was applied to the round window for longer periods of time prior to implantation. The time that dexamethasone need be applied to achieve hearing protection could be reduced by increasing the concentration of steroid, with a 20% application for 30min achieving similar levels of protection to a 60min application of 2% dexamethasone. Hearing protection is improved by increasing the time that dexamethasone is applied to the round window prior to cochlear implantation, and the waiting time can be reduced by increasing the steroid concentration. These results suggest that the diffusion dexamethasone through the cochlea is the prime determinant of the extent of hearing protection.

  16. Improvement in symptoms and cochlear flow with pycnogenol in patients with Meniere's disease and tinnitus.

    PubMed

    Luzzi, R; Belcaro, G; Hu, S; Dugall, M; Hosoi, M; Cacchio, M; Ippolito, E; Corsi, M

    2014-06-01

    The aim of this supplement registry was to evaluate the efficacy of the Pycnogenol® in improving cochlear flow and symptoms in a 6-month follow-up for patients with Meniere's disease (MD), tinnitus and cochlear hypoperfusion. Main signs/symptoms were considered: Spontaneous vertigo, positional vertigo, hearing loss, tinnitus, pressure in the ear, unsteady gait, associated clinical problems, alterations in daily life. All subjects were managed with the best available management (BM); one group used the supplement Pycnogenol (150 mg/day). Cochlear flow and tinnitus were also evaluated. Out of 120 patients incuded in the registry, 55 used Pycnogenol and 52 (controls) were managed only with BM. There was a more significant improvement in all registry items at 3 and 6 months in the Pycnogenol group (P<0.05). The number of lost working days was lower in the Pycnogenol group. At 3 months, 45.4% of subjects using Pycnogenol were completely asymptomatic in comparison with 23.07% of controls. At 6 months 87.3% of the Pycnogenol subjects were asymptomatic compared with 34.6% of controls. Cochlear flow velocity was significantly better (higher flow, higher diastolic component) in the Pycnogenol group (P<0.05). The subjective tinnitus scale decreased in both groups (P<0.05); the decrease was more significant in Pycnogenol subjects (P<0.05) at 3 and 6 months. Symptoms of Meniere's disease, flow at cochlear level and tinnitus improved in Pycnogenol subjects in comparison with best management.

  17. A sustainable model for cochlear implantation in the developing world: perspectives from the Indian subcontinent.

    PubMed

    Sampath Kumar, Raghunandhan; Kameswaran, Mohan

    2018-06-01

    The overall prevalence of deafness in India is 0.2%, but the prevalence in the southern state of Tamil Nadu is much higher (around 0.6%) because of consanguinity. Especially in India, establishing cochlear implantation as a treatment modality for hearing loss has been a daunting task, but in the last decade, the cochlear implantation program has emerged as an unqualified success in many states, with over 20 000 cochlear implantations done till date. Several states are sponsoring free implants to children under the age of 6 years and below poverty line. Nearly 3000 cochlear implantations have been performed in Tamil Nadu under the Chief Minister's Comprehensive Health Insurance Scheme, with the goal to have a 'deafness free Tamil Nadu' by 2025. This scheme covers nearly 40 million people in rural areas. Valuable lessons have been learnt from this social experiment. One of the cornerstones of this scheme is the method to deliver habilitation via satellite centers in rural areas at the doorstep of the patient. The outcomes in peripheral centers were found to be statistically similar to those in the main center and correlated well with duration of habilitation. Opening up satellite centers for habilitation across the state of Tamil Nadu has greatly helped to improve the attendance and outcomes. The Indian model has been hugely successful and has helped start similar cochlear implantation programs in neighboring countries such as Nepal, Sri Lanka and Bangladesh.

  18. Timing and Impact of Hearing Healthcare in Adult Cochlear Implant Recipients: A Rural-Urban Comparison

    PubMed Central

    Hixon, Brian; Chan, Stephen; Adkins, Margaret; Shinn, Jennifer B.; Bush, Matthew L.

    2016-01-01

    Objective The purpose of this study is to compare the timing and impact of hearing healthcare of rural and urban adults with severe hearing loss who use cochlear implants (CI). Study Design Cross-sectional questionnaire study Setting Tertiary referral center Patients Adult cochlear implant recipients. Main Outcome Measures Data collected included county of residence, socioeconomic information, impact of hearing loss on education/employment, and timing of hearing loss treatment. The benefits obtained from cochlear implantation were also evaluated. Results There were 91 participants (32 from urban counties, 26 from moderately rural counties, and 33 for extremely rural counties). Rural participants have a longer commute time to the CI center (p<0.001), lower income (p<0.001) and higher percentage of Medicaid coverage (p=0.004). Compared with urban-metro participants, rural participants with gradually progressive hearing loss had a greater time interval from the onset of hearing loss to obtaining hearing aid amplification (10 years versus 5 years, p=0.04). There was also a greater time interval from onset of hearing loss to the time of cochlear implantation in rural participants (p=0.04). Reported job loss was higher in rural participants than in urban participants (p=0.05). Both groups reported comparable benefit from cochlear implantation. Conclusions Rural CI recipients differ from urban residents in socioeconomic characteristics and may be delayed in timely treatment of hearing loss. Further efforts to expand access to hearing healthcare services may benefit rural adult patients. PMID:27636389

  19. Timing and Impact of Hearing Healthcare in Adult Cochlear Implant Recipients: A Rural-Urban Comparison.

    PubMed

    Hixon, Brian; Chan, Stephen; Adkins, Margaret; Shinn, Jennifer B; Bush, Matthew L

    2016-10-01

    The purpose of this study is to compare the timing and impact of hearing healthcare of rural and urban adults with severe hearing loss who use cochlear implants (CI). Cross-sectional questionnaire study. Tertiary referral center. Adult cochlear implant recipients. Data collected included county of residence, socioeconomic information, impact of hearing loss on education/employment, and timing of hearing loss treatment. The benefits obtained from cochlear implantation were also evaluated. There were 91 participants (32 from urban counties, 26 from moderately rural counties, and 33 for extremely rural counties). Rural participants have a longer commute time to the CI center (p < 0.001), lower income (p < 0.001), and higher percentage of Medicaid coverage (p = 0.004). Compared with urban-metro participants, rural participants with gradually progressive hearing loss had a greater time interval from the onset of hearing loss to obtaining hearing aid amplification (10 yr versus 5 yr, p = 0.04). There was also a greater time interval from onset of hearing loss to the time of cochlear implantation in rural participants (p = 0.04). Reported job loss was higher in rural participants than in urban participants (p = 0.05). Both groups reported comparable benefit from cochlear implantation. Rural CI recipients differ from urban residents in socioeconomic characteristics and may be delayed in timely treatment of hearing loss. Further efforts to expand access to hearing healthcare services may benefit rural adult patients.

  20. Pharmacokinetics of Drug Entry into Cochlear Fluids

    ERIC Educational Resources Information Center

    Salt, Alec N.

    2005-01-01

    The inner ear is exposed to aminoglycosides or other drugs either intentionally or as a side effect of clinical treatments directed at other regions of the body. An understanding of the effects of drugs on the inner ear requires knowledge of the pharmacokinetics of the drug once it reaches the cochlear fluids, specifically how much of it reaches…