Sample records for narrow time interval

  1. Sample size planning for composite reliability coefficients: accuracy in parameter estimation via narrow confidence intervals.

    PubMed

    Terry, Leann; Kelley, Ken

    2012-11-01

    Composite measures play an important role in psychology and related disciplines. Composite measures almost always have error. Correspondingly, it is important to understand the reliability of the scores from any particular composite measure. However, the point estimates of the reliability of composite measures are fallible and thus all such point estimates should be accompanied by a confidence interval. When confidence intervals are wide, there is much uncertainty in the population value of the reliability coefficient. Given the importance of reporting confidence intervals for estimates of reliability, coupled with the undesirability of wide confidence intervals, we develop methods that allow researchers to plan sample size in order to obtain narrow confidence intervals for population reliability coefficients. We first discuss composite reliability coefficients and then provide a discussion on confidence interval formation for the corresponding population value. Using the accuracy in parameter estimation approach, we develop two methods to obtain accurate estimates of reliability by planning sample size. The first method provides a way to plan sample size so that the expected confidence interval width for the population reliability coefficient is sufficiently narrow. The second method ensures that the confidence interval width will be sufficiently narrow with some desired degree of assurance (e.g., 99% assurance that the 95% confidence interval for the population reliability coefficient will be less than W units wide). The effectiveness of our methods was verified with Monte Carlo simulation studies. We demonstrate how to easily implement the methods with easy-to-use and freely available software. ©2011 The British Psychological Society.

  2. Accuracy in parameter estimation for targeted effects in structural equation modeling: sample size planning for narrow confidence intervals.

    PubMed

    Lai, Keke; Kelley, Ken

    2011-06-01

    In addition to evaluating a structural equation model (SEM) as a whole, often the model parameters are of interest and confidence intervals for those parameters are formed. Given a model with a good overall fit, it is entirely possible for the targeted effects of interest to have very wide confidence intervals, thus giving little information about the magnitude of the population targeted effects. With the goal of obtaining sufficiently narrow confidence intervals for the model parameters of interest, sample size planning methods for SEM are developed from the accuracy in parameter estimation approach. One method plans for the sample size so that the expected confidence interval width is sufficiently narrow. An extended procedure ensures that the obtained confidence interval will be no wider than desired, with some specified degree of assurance. A Monte Carlo simulation study was conducted that verified the effectiveness of the procedures in realistic situations. The methods developed have been implemented in the MBESS package in R so that they can be easily applied by researchers. © 2011 American Psychological Association

  3. VARIABLE TIME-INTERVAL GENERATOR

    DOEpatents

    Gross, J.E.

    1959-10-31

    This patent relates to a pulse generator and more particularly to a time interval generator wherein the time interval between pulses is precisely determined. The variable time generator comprises two oscillators with one having a variable frequency output and the other a fixed frequency output. A frequency divider is connected to the variable oscillator for dividing its frequency by a selected factor and a counter is used for counting the periods of the fixed oscillator occurring during a cycle of the divided frequency of the variable oscillator. This defines the period of the variable oscillator in terms of that of the fixed oscillator. A circuit is provided for selecting as a time interval a predetermined number of periods of the variable oscillator. The output of the generator consists of a first pulse produced by a trigger circuit at the start of the time interval and a second pulse marking the end of the time interval produced by the same trigger circuit.

  4. TIME-INTERVAL MEASURING DEVICE

    DOEpatents

    Gross, J.E.

    1958-04-15

    An electronic device for measuring the time interval between two control pulses is presented. The device incorporates part of a previous approach for time measurement, in that pulses from a constant-frequency oscillator are counted during the interval between the control pulses. To reduce the possible error in counting caused by the operation of the counter gating circuit at various points in the pulse cycle, the described device provides means for successively delaying the pulses for a fraction of the pulse period so that a final delay of one period is obtained and means for counting the pulses before and after each stage of delay during the time interval whereby a plurality of totals is obtained which may be averaged and multplied by the pulse period to obtain an accurate time- Interval measurement.

  5. Time interval measurement device based on surface acoustic wave filter excitation, providing 1 ps precision and stability.

    PubMed

    Panek, Petr; Prochazka, Ivan

    2007-09-01

    This article deals with the time interval measurement device, which is based on a surface acoustic wave (SAW) filter as a time interpolator. The operating principle is based on the fact that a transversal SAW filter excited by a short pulse can generate a finite signal with highly suppressed spectra outside a narrow frequency band. If the responses to two excitations are sampled at clock ticks, they can be precisely reconstructed from a finite number of samples and then compared so as to determine the time interval between the two excitations. We have designed and constructed a two-channel time interval measurement device which allows independent timing of two events and evaluation of the time interval between them. The device has been constructed using commercially available components. The experimental results proved the concept. We have assessed the single-shot time interval measurement precision of 1.3 ps rms that corresponds to the time of arrival precision of 0.9 ps rms in each channel. The temperature drift of the measured time interval on temperature is lower than 0.5 ps/K, and the long term stability is better than +/-0.2 ps/h. These are to our knowledge the best values reported for the time interval measurement device. The results are in good agreement with the error budget based on the theoretical analysis.

  6. Detection of abnormal item based on time intervals for recommender systems.

    PubMed

    Gao, Min; Yuan, Quan; Ling, Bin; Xiong, Qingyu

    2014-01-01

    With the rapid development of e-business, personalized recommendation has become core competence for enterprises to gain profits and improve customer satisfaction. Although collaborative filtering is the most successful approach for building a recommender system, it suffers from "shilling" attacks. In recent years, the research on shilling attacks has been greatly improved. However, the approaches suffer from serious problem in attack model dependency and high computational cost. To solve the problem, an approach for the detection of abnormal item is proposed in this paper. In the paper, two common features of all attack models are analyzed at first. A revised bottom-up discretized approach is then proposed based on time intervals and the features for the detection. The distributions of ratings in different time intervals are compared to detect anomaly based on the calculation of chi square distribution (χ(2)). We evaluated our approach on four types of items which are defined according to the life cycles of these items. The experimental results show that the proposed approach achieves a high detection rate with low computational cost when the number of attack profiles is more than 15. It improves the efficiency in shilling attacks detection by narrowing down the suspicious users.

  7. Intact interval timing in circadian CLOCK mutants.

    PubMed

    Cordes, Sara; Gallistel, C R

    2008-08-28

    While progress has been made in determining the molecular basis for the circadian clock, the mechanism by which mammalian brains time intervals measured in seconds to minutes remains a mystery. An obvious question is whether the interval-timing mechanism shares molecular machinery with the circadian timing mechanism. In the current study, we trained circadian CLOCK +/- and -/- mutant male mice in a peak-interval procedure with 10 and 20-s criteria. The mutant mice were more active than their wild-type littermates, but there were no reliable deficits in the accuracy or precision of their timing as compared with wild-type littermates. This suggests that expression of the CLOCK protein is not necessary for normal interval timing.

  8. Intact Interval Timing in Circadian CLOCK Mutants

    PubMed Central

    Cordes, Sara; Gallistel, C. R.

    2008-01-01

    While progress has been made in determining the molecular basis for the circadian clock, the mechanism by which mammalian brains time intervals measured in seconds to minutes remains a mystery. An obvious question is whether the interval timing mechanism shares molecular machinery with the circadian timing mechanism. In the current study, we trained circadian CLOCK +/− and −/− mutant male mice in a peak-interval procedure with 10 and 20-s criteria. The mutant mice were more active than their wild-type littermates, but there were no reliable deficits in the accuracy or precision of their timing as compared with wild-type littermates. This suggests that expression of the CLOCK protein is not necessary for normal interval timing. PMID:18602902

  9. Fast transfer of crossmodal time interval training.

    PubMed

    Chen, Lihan; Zhou, Xiaolin

    2014-06-01

    Sub-second time perception is essential for many important sensory and perceptual tasks including speech perception, motion perception, motor coordination, and crossmodal interaction. This study investigates to what extent the ability to discriminate sub-second time intervals acquired in one sensory modality can be transferred to another modality. To this end, we used perceptual classification of visual Ternus display (Ternus in Psychol Forsch 7:81-136, 1926) to implicitly measure participants' interval perception in pre- and posttests and implemented an intra- or crossmodal sub-second interval discrimination training protocol in between the tests. The Ternus display elicited either an "element motion" or a "group motion" percept, depending on the inter-stimulus interval between the two visual frames. The training protocol required participants to explicitly compare the interval length between a pair of visual, auditory, or tactile stimuli with a standard interval or to implicitly perceive the length of visual, auditory, or tactile intervals by completing a non-temporal task (discrimination of auditory pitch or tactile intensity). Results showed that after fast explicit training of interval discrimination (about 15 min), participants improved their ability to categorize the visual apparent motion in Ternus displays, although the training benefits were mild for visual timing training. However, the benefits were absent for implicit interval training protocols. This finding suggests that the timing ability in one modality can be rapidly acquired and used to improve timing-related performance in another modality and that there may exist a central clock for sub-second temporal processing, although modality-specific perceptual properties may constrain the functioning of this clock.

  10. Department of Defense Precise Time and Time Interval program improvement plan

    NASA Technical Reports Server (NTRS)

    Bowser, J. R.

    1981-01-01

    The United States Naval Observatory is responsible for ensuring uniformity in precise time and time interval operations including measurements, the establishment of overall DOD requirements for time and time interval, and the accomplishment of objectives requiring precise time and time interval with minimum cost. An overview of the objectives, the approach to the problem, the schedule, and a status report, including significant findings relative to organizational relationships, current directives, principal PTTI users, and future requirements as currently identified by the users are presented.

  11. Extended Endoscopic Endonasal Resection of a Suprasellar and Third Ventricular Retrochiasmatic Craniopharyngioma with a Narrow Pituitary Gland-Optic Chiasm Interval: Techniques to Optimize Resection.

    PubMed

    Kenning, Tyler J; Pinheiro-Neto, Carlos D

    2018-04-01

    The extended endoscopic endonasal approach can be utilized to surgically treat pathology within the suprasellar space. This relies on a sufficient corridor and interval between the superior aspect of the pituitary gland and the optic chiasm. Tumors located in the retrochiasmatic space and within the third ventricle, however, may not have a widened interval through which to work. With mass effect on the superior and posterior aspect of the optic chiasm, the corridor between the chiasm and the pituitary gland might even be further narrowed. This may negate the possibility of utilizing the endoscopic endonasal approach for the management of pathology in this location. We present a case of a retrochiasmatic craniopharyngioma with a narrow resection corridor that was treated with the extended endoscopic approach and we review techniques to potentially overcome this limitation. The link to the video can be found at: https://youtu.be/ogRZj-aBqeQ .

  12. High resolution time interval meter

    DOEpatents

    Martin, A.D.

    1986-05-09

    Method and apparatus are provided for measuring the time interval between two events to a higher resolution than reliability available from conventional circuits and component. An internal clock pulse is provided at a frequency compatible with conventional component operating frequencies for reliable operation. Lumped constant delay circuits are provided for generating outputs at delay intervals corresponding to the desired high resolution. An initiation START pulse is input to generate first high resolution data. A termination STOP pulse is input to generate second high resolution data. Internal counters count at the low frequency internal clock pulse rate between the START and STOP pulses. The first and second high resolution data are logically combined to directly provide high resolution data to one counter and correct the count in the low resolution counter to obtain a high resolution time interval measurement.

  13. Recurrence time statistics for finite size intervals

    NASA Astrophysics Data System (ADS)

    Altmann, Eduardo G.; da Silva, Elton C.; Caldas, Iberê L.

    2004-12-01

    We investigate the statistics of recurrences to finite size intervals for chaotic dynamical systems. We find that the typical distribution presents an exponential decay for almost all recurrence times except for a few short times affected by a kind of memory effect. We interpret this effect as being related to the unstable periodic orbits inside the interval. Although it is restricted to a few short times it changes the whole distribution of recurrences. We show that for systems with strong mixing properties the exponential decay converges to the Poissonian statistics when the width of the interval goes to zero. However, we alert that special attention to the size of the interval is required in order to guarantee that the short time memory effect is negligible when one is interested in numerically or experimentally calculated Poincaré recurrence time statistics.

  14. Use of precision time and time interval (PTTI)

    NASA Technical Reports Server (NTRS)

    Taylor, J. D.

    1974-01-01

    A review of range time synchronization methods are discussed as an important aspect of range operations. The overall capabilities of various missile ranges to determine precise time of day by synchronizing to available references and applying this time point to instrumentation for time interval measurements are described.

  15. The Anaesthetic-ECT Time Interval in Electroconvulsive Therapy Practice--Is It Time to Time?

    PubMed

    Gálvez, Verònica; Hadzi-Pavlovic, Dusan; Wark, Harry; Harper, Simon; Leyden, John; Loo, Colleen K

    2016-01-01

    Because most common intravenous anaesthetics used in ECT have anticonvulsant properties, their plasma-brain concentration at the time of seizure induction might affect seizure expression. The quality of ECT seizure expression has been repeatedly associated with efficacy outcomes. The time interval between the anaesthetic bolus injection and the ECT stimulus (anaesthetic-ECT time interval) will determine the anaesthetic plasma-brain concentration when the ECT stimulus is administered. The aim of this study was to examine the effect of the anaesthetic-ECT time interval on ECT seizure quality and duration. The anaesthetic-ECT time interval was recorded in 771 ECT sessions (84 patients). Right unilateral brief pulse ECT was applied. Anaesthesia given was propofol (1-2 mg/kg) and succinylcholine (0.5-1.0 mg/kg). Seizure quality indices (slow wave onset, amplitude, regularity, stereotypy and post-ictal suppression) and duration were rated through a structured rating scale by a single blinded trained rater. Linear Mixed Effects Models analysed the effect of the anaesthetic-ECT time interval on seizure quality indices, controlling for propofol dose (mg), ECT charge (mC), ECT session number, days between ECT, age (years), initial seizure threshold (mC) and concurrent medication. Longer anaesthetic-ECT time intervals lead to significantly higher quality seizures (p < 0.001 for amplitude, regularity, stereotypy and post-ictal suppression). These results suggest that the anaesthetic-ECT time interval is an important factor to consider in ECT practice. This time interval should be extended to as long as practically possible to facilitate the production of better quality seizures. Close collaboration between the anaesthetist and the psychiatrist is essential. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Interval Timing Accuracy and Scalar Timing in C57BL/6 Mice

    PubMed Central

    Buhusi, Catalin V.; Aziz, Dyana; Winslow, David; Carter, Rickey E.; Swearingen, Joshua E.; Buhusi, Mona C.

    2010-01-01

    In many species, interval timing behavior is accurate—appropriate estimated durations—and scalar—errors vary linearly with estimated durations. While accuracy has been previously examined, scalar timing has not been yet clearly demonstrated in house mice (Mus musculus), raising concerns about mouse models of human disease. We estimated timing accuracy and precision in C57BL/6 mice, the most used background strain for genetic models of human disease, in a peak-interval procedure with multiple intervals. Both when timing two intervals (Experiment 1) or three intervals (Experiment 2), C57BL/6 mice demonstrated varying degrees of timing accuracy. Importantly, both at individual and group level, their precision varied linearly with the subjective estimated duration. Further evidence for scalar timing was obtained using an intraclass correlation statistic. This is the first report of consistent, reliable scalar timing in a sizable sample of house mice, thus validating the PI procedure as a valuable technique, the intraclass correlation statistic as a powerful test of the scalar property, and the C57BL/6 strain as a suitable background for behavioral investigations of genetically engineered mice modeling disorders of interval timing. PMID:19824777

  17. Linkage Disequilibrium Mapping in Domestic Dog Breeds Narrows the Progressive Rod-Cone Degeneration (prcd) Interval and Identifies Ancestral Disease Transmitting Chromosome

    PubMed Central

    Goldstein, Orly; Zangerl, Barbara; Pearce-Kelling, Sue; Sidjanin, Duska J.; Kijas, James W.; Felix, Jeanette; Acland, Gregory M; Aguirre, Gustavo D.

    2014-01-01

    Canine progressive rod-cone degeneration (prcd) is a retinal disease previously mapped to a broad, gene-rich centromeric region of canine chromosome 9. As allelic disorders are present in multiple breeds, we used linkage disequilibrium (LD) to narrow the ∼6.4 Mb interval candidate region. Multiple dog breeds, each representing genetically isolated populations, were typed for SNPs and other polymorphisms identified from BACs. The candidate region was initially localized to a 1.5 Mb zero recombination interval between growth factor receptor-bound protein 2 (GRB2) and SEC14-like 1 (SEC14L). A fine-scale haplotype of the region was developed which reduced the LD interval to 106 Kb, and identified a conserved haplotype of 98 polymorphisms present in all prcd-affected chromosomes from 14 different dog breeds. The findings strongly suggest that a common ancestor transmitted the prcd disease allele to many of the modern dog breeds, and demonstrate the power of LD approach in the canine model. PMID:16859891

  18. Automatic Identification of Systolic Time Intervals in Seismocardiogram

    PubMed Central

    Shafiq, Ghufran; Tatinati, Sivanagaraja; Ang, Wei Tech; Veluvolu, Kalyana C.

    2016-01-01

    Continuous and non-invasive monitoring of hemodynamic parameters through unobtrusive wearable sensors can potentially aid in early detection of cardiac abnormalities, and provides a viable solution for long-term follow-up of patients with chronic cardiovascular diseases without disrupting the daily life activities. Electrocardiogram (ECG) and siesmocardiogram (SCG) signals can be readily acquired from light-weight electrodes and accelerometers respectively, which can be employed to derive systolic time intervals (STI). For this purpose, automated and accurate annotation of the relevant peaks in these signals is required, which is challenging due to the inter-subject morphological variability and noise prone nature of SCG signal. In this paper, an approach is proposed to automatically annotate the desired peaks in SCG signal that are related to STI by utilizing the information of peak detected in the sliding template to narrow-down the search for the desired peak in actual SCG signal. Experimental validation of this approach performed in conventional/controlled supine and realistic/challenging seated conditions, containing over 5600 heart beat cycles shows good performance and robustness of the proposed approach in noisy conditions. Automated measurement of STI in wearable configuration can provide a quantified cardiac health index for long-term monitoring of patients, elderly people at risk and health-enthusiasts. PMID:27874050

  19. Automatic Identification of Systolic Time Intervals in Seismocardiogram

    NASA Astrophysics Data System (ADS)

    Shafiq, Ghufran; Tatinati, Sivanagaraja; Ang, Wei Tech; Veluvolu, Kalyana C.

    2016-11-01

    Continuous and non-invasive monitoring of hemodynamic parameters through unobtrusive wearable sensors can potentially aid in early detection of cardiac abnormalities, and provides a viable solution for long-term follow-up of patients with chronic cardiovascular diseases without disrupting the daily life activities. Electrocardiogram (ECG) and siesmocardiogram (SCG) signals can be readily acquired from light-weight electrodes and accelerometers respectively, which can be employed to derive systolic time intervals (STI). For this purpose, automated and accurate annotation of the relevant peaks in these signals is required, which is challenging due to the inter-subject morphological variability and noise prone nature of SCG signal. In this paper, an approach is proposed to automatically annotate the desired peaks in SCG signal that are related to STI by utilizing the information of peak detected in the sliding template to narrow-down the search for the desired peak in actual SCG signal. Experimental validation of this approach performed in conventional/controlled supine and realistic/challenging seated conditions, containing over 5600 heart beat cycles shows good performance and robustness of the proposed approach in noisy conditions. Automated measurement of STI in wearable configuration can provide a quantified cardiac health index for long-term monitoring of patients, elderly people at risk and health-enthusiasts.

  20. Versatile all-digital time interval measuring system

    NASA Astrophysics Data System (ADS)

    Vyhlidal, David; Cech, Miroslav

    2011-06-01

    This paper describes a design and performance of a versatile all-digital time interval measuring system. The measurement method is based on an interpolation principle. In this principle the time interval is first roughly digitized by a coarse counter driven by a high stability reference clock and the fractions between the clock periods are measured by two Time-to-Digital Converter chips TDC-GPX manufactured by Acam messelectronic. Control circuits allow programmable customization of the system to satisfy many applications such as laser range finding, event counting, or time-of-flight measurements in various physics experiments. The system has two reference clocks inputs and two independent channels for measuring start and stop events. Only one 40 MHz reference is required for the measurement. The second reference can be, for example, 1 PPS (Pulse per Second) signal from a GPS (Global Positioning System) to time tag events. Time intervals are measured using the highest resolution mode of the TDC-GPX chips. The resolution of each chip is software programmable and is PLL (Phase Locked Loop) stabilized against temperature and voltage variations. The system can achieve a timing resolution better than 15 ps rms with up to 90 kHz repetition rate. The time interval measurement range is from 0 ps up to 1 second. The power consumption of the whole system is 18 W including an embedded computer board and an LCD (Liquid Crystal Display) screen. The embedded computer controls the whole system, collects and evaluates measurement data and with the display provides a user interface. The system is implemented using commercially available components.

  1. High resolution time interval counter

    DOEpatents

    Condreva, Kenneth J.

    1994-01-01

    A high resolution counter circuit measures the time interval between the occurrence of an initial and a subsequent electrical pulse to two nanoseconds resolution using an eight megahertz clock. The circuit includes a main counter for receiving electrical pulses and generating a binary word--a measure of the number of eight megahertz clock pulses occurring between the signals. A pair of first and second pulse stretchers receive the signal and generate a pair of output signals whose widths are approximately sixty-four times the time between the receipt of the signals by the respective pulse stretchers and the receipt by the respective pulse stretchers of a second subsequent clock pulse. Output signals are thereafter supplied to a pair of start and stop counters operable to generate a pair of binary output words representative of the measure of the width of the pulses to a resolution of two nanoseconds. Errors associated with the pulse stretchers are corrected by providing calibration data to both stretcher circuits, and recording start and stop counter values. Stretched initial and subsequent signals are combined with autocalibration data and supplied to an arithmetic logic unit to determine the time interval in nanoseconds between the pair of electrical pulses being measured.

  2. High resolution time interval counter

    DOEpatents

    Condreva, K.J.

    1994-07-26

    A high resolution counter circuit measures the time interval between the occurrence of an initial and a subsequent electrical pulse to two nanoseconds resolution using an eight megahertz clock. The circuit includes a main counter for receiving electrical pulses and generating a binary word--a measure of the number of eight megahertz clock pulses occurring between the signals. A pair of first and second pulse stretchers receive the signal and generate a pair of output signals whose widths are approximately sixty-four times the time between the receipt of the signals by the respective pulse stretchers and the receipt by the respective pulse stretchers of a second subsequent clock pulse. Output signals are thereafter supplied to a pair of start and stop counters operable to generate a pair of binary output words representative of the measure of the width of the pulses to a resolution of two nanoseconds. Errors associated with the pulse stretchers are corrected by providing calibration data to both stretcher circuits, and recording start and stop counter values. Stretched initial and subsequent signals are combined with autocalibration data and supplied to an arithmetic logic unit to determine the time interval in nanoseconds between the pair of electrical pulses being measured. 3 figs.

  3. A model of interval timing by neural integration.

    PubMed

    Simen, Patrick; Balci, Fuat; de Souza, Laura; Cohen, Jonathan D; Holmes, Philip

    2011-06-22

    We show that simple assumptions about neural processing lead to a model of interval timing as a temporal integration process, in which a noisy firing-rate representation of time rises linearly on average toward a response threshold over the course of an interval. Our assumptions include: that neural spike trains are approximately independent Poisson processes, that correlations among them can be largely cancelled by balancing excitation and inhibition, that neural populations can act as integrators, and that the objective of timed behavior is maximal accuracy and minimal variance. The model accounts for a variety of physiological and behavioral findings in rodents, monkeys, and humans, including ramping firing rates between the onset of reward-predicting cues and the receipt of delayed rewards, and universally scale-invariant response time distributions in interval timing tasks. It furthermore makes specific, well-supported predictions about the skewness of these distributions, a feature of timing data that is usually ignored. The model also incorporates a rapid (potentially one-shot) duration-learning procedure. Human behavioral data support the learning rule's predictions regarding learning speed in sequences of timed responses. These results suggest that simple, integration-based models should play as prominent a role in interval timing theory as they do in theories of perceptual decision making, and that a common neural mechanism may underlie both types of behavior.

  4. A model of interval timing by neural integration

    PubMed Central

    Simen, Patrick; Balci, Fuat; deSouza, Laura; Cohen, Jonathan D.; Holmes, Philip

    2011-01-01

    We show that simple assumptions about neural processing lead to a model of interval timing as a temporal integration process, in which a noisy firing-rate representation of time rises linearly on average toward a response threshold over the course of an interval. Our assumptions include: that neural spike trains are approximately independent Poisson processes; that correlations among them can be largely cancelled by balancing excitation and inhibition; that neural populations can act as integrators; and that the objective of timed behavior is maximal accuracy and minimal variance. The model accounts for a variety of physiological and behavioral findings in rodents, monkeys and humans, including ramping firing rates between the onset of reward-predicting cues and the receipt of delayed rewards, and universally scale-invariant response time distributions in interval timing tasks. It furthermore makes specific, well-supported predictions about the skewness of these distributions, a feature of timing data that is usually ignored. The model also incorporates a rapid (potentially one-shot) duration-learning procedure. Human behavioral data support the learning rule’s predictions regarding learning speed in sequences of timed responses. These results suggest that simple, integration-based models should play as prominent a role in interval timing theory as they do in theories of perceptual decision making, and that a common neural mechanism may underlie both types of behavior. PMID:21697374

  5. It's time to fear! Interval timing in odor fear conditioning in rats

    PubMed Central

    Shionoya, Kiseko; Hegoburu, Chloé; Brown, Bruce L.; Sullivan, Regina M.; Doyère, Valérie; Mouly, Anne-Marie

    2013-01-01

    Time perception is crucial to goal attainment in humans and other animals, and interval timing also guides fundamental animal behaviors. Accumulating evidence has made it clear that in associative learning, temporal relations between events are encoded, and a few studies suggest this temporal learning occurs very rapidly. Most of these studies, however, have used methodologies that do not permit investigating the emergence of this temporal learning. In the present study we monitored respiration, ultrasonic vocalization (USV) and freezing behavior in rats in order to perform fine-grain analysis of fear responses during odor fear conditioning. In this paradigm an initially neutral odor (the conditioned stimulus, CS) predicted the arrival of an aversive unconditioned stimulus (US, footshock) at a fixed 20-s time interval. We first investigated the development of a temporal pattern of responding related to CS-US interval duration. The data showed that during acquisition with odor-shock pairings, a temporal response pattern of respiration rate was observed. Changing the CS-US interval duration from 20-s to 30-s resulted in a shift of the temporal response pattern appropriate to the new duration thus demonstrating that the pattern reflected the learning of the CS-US interval. A temporal pattern was also observed during a retention test 24 h later for both respiration and freezing measures, suggesting that the animals had stored the interval duration in long-term memory. We then investigated the role of intra-amygdalar dopaminergic transmission in interval timing. For this purpose, the D1 dopaminergic receptors antagonist SCH23390 was infused in the basolateral amygdala before conditioning. This resulted in an alteration of timing behavior, as reflected in differential temporal patterns between groups observed in a 24 h retention test off drug. The present data suggest that D1 receptor dopaminergic transmission within the amygdala is involved in temporal processing. PMID

  6. The Behavioral Economics of Choice and Interval Timing

    PubMed Central

    Jozefowiez, J.; Staddon, J. E. R.; Cerutti, D. T.

    2009-01-01

    We propose a simple behavioral economic model (BEM) describing how reinforcement and interval timing interact. The model assumes a Weber-law-compliant logarithmic representation of time. Associated with each represented time value are the payoffs that have been obtained for each possible response. At a given real time, the response with the highest payoff is emitted. The model accounts for a wide range of data from procedures such as simple bisection, metacognition in animals, economic effects in free-operant psychophysical procedures and paradoxical choice in double-bisection procedures. Although it assumes logarithmic time representation, it can also account for data from the time-left procedure usually cited in support of linear time representation. It encounters some difficulties in complex free-operant choice procedures, such as concurrent mixed fixed-interval schedules as well as some of the data on double bisection, that may involve additional processes. Overall, BEM provides a theoretical framework for understanding how reinforcement and interval timing work together to determine choice between temporally differentiated reinforcers. PMID:19618985

  7. Specifying real-time systems with interval logic

    NASA Technical Reports Server (NTRS)

    Rushby, John

    1988-01-01

    Pure temporal logic makes no reference to time. An interval temporal logic and an extension to that logic which includes real time constraints are described. The application of this logic by giving a specification for the well-known lift (elevator) example is demonstrated. It is shown how interval logic can be extended to include a notion of process. How the specification language and verification environment of EHDM could be enhanced to support this logic is described. A specification of the alternating bit protocol in this extended version of the specification language of EHDM is given.

  8. Single-channel autocorrelation functions: the effects of time interval omission.

    PubMed Central

    Ball, F G; Sansom, M S

    1988-01-01

    We present a general mathematical framework for analyzing the dynamic aspects of single channel kinetics incorporating time interval omission. An algorithm for computing model autocorrelation functions, incorporating time interval omission, is described. We show, under quite general conditions, that the form of these autocorrelations is identical to that which would be obtained if time interval omission was absent. We also show, again under quite general conditions, that zero correlations are necessarily a consequence of the underlying gating mechanism and not an artefact of time interval omission. The theory is illustrated by a numerical study of an allosteric model for the gating mechanism of the locust muscle glutamate receptor-channel. PMID:2455553

  9. Interresponse Time Structures in Variable-Ratio and Variable-Interval Schedules

    ERIC Educational Resources Information Center

    Bowers, Matthew T.; Hill, Jade; Palya, William L.

    2008-01-01

    The interresponse-time structures of pigeon key pecking were examined under variable-ratio, variable-interval, and variable-interval plus linear feedback schedules. Whereas the variable-ratio and variable-interval plus linear feedback schedules generally resulted in a distinct group of short interresponse times and a broad distribution of longer…

  10. Learned Interval Time Facilitates Associate Memory Retrieval

    ERIC Educational Resources Information Center

    van de Ven, Vincent; Kochs, Sarah; Smulders, Fren; De Weerd, Peter

    2017-01-01

    The extent to which time is represented in memory remains underinvestigated. We designed a time paired associate task (TPAT) in which participants implicitly learned cue-time-target associations between cue-target pairs and specific cue-target intervals. During subsequent memory testing, participants showed increased accuracy of identifying…

  11. Sunspot Time Series: Passive and Active Intervals

    NASA Astrophysics Data System (ADS)

    Zięba, S.; Nieckarz, Z.

    2014-07-01

    Solar activity slowly and irregularly decreases from the first spotless day (FSD) in the declining phase of the old sunspot cycle and systematically, but also in an irregular way, increases to the new cycle maximum after the last spotless day (LSD). The time interval between the first and the last spotless day can be called the passive interval (PI), while the time interval from the last spotless day to the first one after the new cycle maximum is the related active interval (AI). Minima of solar cycles are inside PIs, while maxima are inside AIs. In this article, we study the properties of passive and active intervals to determine the relation between them. We have found that some properties of PIs, and related AIs, differ significantly between two group of solar cycles; this has allowed us to classify Cycles 8 - 15 as passive cycles, and Cycles 17 - 23 as active ones. We conclude that the solar activity in the PI declining phase (a descending phase of the previous cycle) determines the strength of the approaching maximum in the case of active cycles, while the activity of the PI rising phase (a phase of the ongoing cycle early growth) determines the strength of passive cycles. This can have implications for solar dynamo models. Our approach indicates the important role of solar activity during the declining and the rising phases of the solar-cycle minimum.

  12. The Time Is Up: Compression of Visual Time Interval Estimations of Bimodal Aperiodic Patterns

    PubMed Central

    Duarte, Fabiola; Lemus, Luis

    2017-01-01

    The ability to estimate time intervals subserves many of our behaviors and perceptual experiences. However, it is not clear how aperiodic (AP) stimuli affect our perception of time intervals across sensory modalities. To address this question, we evaluated the human capacity to discriminate between two acoustic (A), visual (V) or audiovisual (AV) time intervals of trains of scattered pulses. We first measured the periodicity of those stimuli and then sought for correlations with the accuracy and reaction times (RTs) of the subjects. We found that, for all time intervals tested in our experiment, the visual system consistently perceived AP stimuli as being shorter than the periodic (P) ones. In contrast, such a compression phenomenon was not apparent during auditory trials. Our conclusions are: first, the subjects exposed to P stimuli are more likely to measure their durations accurately. Second, perceptual time compression occurs for AP visual stimuli. Lastly, AV discriminations are determined by A dominance rather than by AV enhancement. PMID:28848406

  13. Monitoring molecular interactions using photon arrival-time interval distribution analysis

    DOEpatents

    Laurence, Ted A [Livermore, CA; Weiss, Shimon [Los Angels, CA

    2009-10-06

    A method for analyzing/monitoring the properties of species that are labeled with fluorophores. A detector is used to detect photons emitted from species that are labeled with one or more fluorophores and located in a confocal detection volume. The arrival time of each of the photons is determined. The interval of time between various photon pairs is then determined to provide photon pair intervals. The number of photons that have arrival times within the photon pair intervals is also determined. The photon pair intervals are then used in combination with the corresponding counts of intervening photons to analyze properties and interactions of the molecules including brightness, concentration, coincidence and transit time. The method can be used for analyzing single photon streams and multiple photon streams.

  14. Interval timing in genetically modified mice: a simple paradigm

    PubMed Central

    Balci, F.; Papachristos, E. B.; Gallistel, C. R.; Brunner, D.; Gibson, J.; Shumyatsky, G. P.

    2009-01-01

    We describe a behavioral screen for the quantitative study of interval timing and interval memory in mice. Mice learn to switch from a short-latency feeding station to a long-latency station when the short latency has passed without a feeding. The psychometric function is the cumulative distribution of switch latencies. Its median measures timing accuracy and its interquartile interval measures timing precision. Next, using this behavioral paradigm, we have examined mice with a gene knockout of the receptor for gastrin-releasing peptide that show enhanced (i.e. prolonged) freezing in fear conditioning. We have tested the hypothesis that the mutants freeze longer because they are more uncertain than wild types about when to expect the electric shock. The knockouts however show normal accuracy and precision in timing, so we have rejected this alternative hypothesis. Last, we conduct the pharmacological validation of our behavioral screen using D-amphetamine and methamphetamine. We suggest including the analysis of interval timing and temporal memory in tests of genetically modified mice for learning and memory and argue that our paradigm allows this to be done simply and efficiently. PMID:17696995

  15. Interval timing in genetically modified mice: a simple paradigm.

    PubMed

    Balci, F; Papachristos, E B; Gallistel, C R; Brunner, D; Gibson, J; Shumyatsky, G P

    2008-04-01

    We describe a behavioral screen for the quantitative study of interval timing and interval memory in mice. Mice learn to switch from a short-latency feeding station to a long-latency station when the short latency has passed without a feeding. The psychometric function is the cumulative distribution of switch latencies. Its median measures timing accuracy and its interquartile interval measures timing precision. Next, using this behavioral paradigm, we have examined mice with a gene knockout of the receptor for gastrin-releasing peptide that show enhanced (i.e. prolonged) freezing in fear conditioning. We have tested the hypothesis that the mutants freeze longer because they are more uncertain than wild types about when to expect the electric shock. The knockouts however show normal accuracy and precision in timing, so we have rejected this alternative hypothesis. Last, we conduct the pharmacological validation of our behavioral screen using d-amphetamine and methamphetamine. We suggest including the analysis of interval timing and temporal memory in tests of genetically modified mice for learning and memory and argue that our paradigm allows this to be done simply and efficiently.

  16. Bayesian analyses of time-interval data for environmental radiation monitoring.

    PubMed

    Luo, Peng; Sharp, Julia L; DeVol, Timothy A

    2013-01-01

    Time-interval (time difference between two consecutive pulses) analysis based on the principles of Bayesian inference was investigated for online radiation monitoring. Using experimental and simulated data, Bayesian analysis of time-interval data [Bayesian (ti)] was compared with Bayesian and a conventional frequentist analysis of counts in a fixed count time [Bayesian (cnt) and single interval test (SIT), respectively]. The performances of the three methods were compared in terms of average run length (ARL) and detection probability for several simulated detection scenarios. Experimental data were acquired with a DGF-4C system in list mode. Simulated data were obtained using Monte Carlo techniques to obtain a random sampling of the Poisson distribution. All statistical algorithms were developed using the R Project for statistical computing. Bayesian analysis of time-interval information provided a similar detection probability as Bayesian analysis of count information, but the authors were able to make a decision with fewer pulses at relatively higher radiation levels. In addition, for the cases with very short presence of the source (< count time), time-interval information is more sensitive to detect a change than count information since the source data is averaged by the background data over the entire count time. The relationships of the source time, change points, and modifications to the Bayesian approach for increasing detection probability are presented.

  17. Ratio-based lengths of intervals to improve fuzzy time series forecasting.

    PubMed

    Huarng, Kunhuang; Yu, Tiffany Hui-Kuang

    2006-04-01

    The objective of this study is to explore ways of determining the useful lengths of intervals in fuzzy time series. It is suggested that ratios, instead of equal lengths of intervals, can more properly represent the intervals among observations. Ratio-based lengths of intervals are, therefore, proposed to improve fuzzy time series forecasting. Algebraic growth data, such as enrollments and the stock index, and exponential growth data, such as inventory demand, are chosen as the forecasting targets, before forecasting based on the various lengths of intervals is performed. Furthermore, sensitivity analyses are also carried out for various percentiles. The ratio-based lengths of intervals are found to outperform the effective lengths of intervals, as well as the arbitrary ones in regard to the different statistical measures. The empirical analysis suggests that the ratio-based lengths of intervals can also be used to improve fuzzy time series forecasting.

  18. Modeling stream fish distributions using interval-censored detection times.

    PubMed

    Ferreira, Mário; Filipe, Ana Filipa; Bardos, David C; Magalhães, Maria Filomena; Beja, Pedro

    2016-08-01

    Controlling for imperfect detection is important for developing species distribution models (SDMs). Occupancy-detection models based on the time needed to detect a species can be used to address this problem, but this is hindered when times to detection are not known precisely. Here, we extend the time-to-detection model to deal with detections recorded in time intervals and illustrate the method using a case study on stream fish distribution modeling. We collected electrofishing samples of six fish species across a Mediterranean watershed in Northeast Portugal. Based on a Bayesian hierarchical framework, we modeled the probability of water presence in stream channels, and the probability of species occupancy conditional on water presence, in relation to environmental and spatial variables. We also modeled time-to-first detection conditional on occupancy in relation to local factors, using modified interval-censored exponential survival models. Posterior distributions of occupancy probabilities derived from the models were used to produce species distribution maps. Simulations indicated that the modified time-to-detection model provided unbiased parameter estimates despite interval-censoring. There was a tendency for spatial variation in detection rates to be primarily influenced by depth and, to a lesser extent, stream width. Species occupancies were consistently affected by stream order, elevation, and annual precipitation. Bayesian P-values and AUCs indicated that all models had adequate fit and high discrimination ability, respectively. Mapping of predicted occupancy probabilities showed widespread distribution by most species, but uncertainty was generally higher in tributaries and upper reaches. The interval-censored time-to-detection model provides a practical solution to model occupancy-detection when detections are recorded in time intervals. This modeling framework is useful for developing SDMs while controlling for variation in detection rates, as it

  19. Atomic temporal interval relations in branching time: calculation and application

    NASA Astrophysics Data System (ADS)

    Anger, Frank D.; Ladkin, Peter B.; Rodriguez, Rita V.

    1991-03-01

    A practical method of reasoning about intervals in a branching-time model which is dense, unbounded, future-branching, without rejoining branches is presented. The discussion is based on heuristic constraint- propagation techniques using the relation algebra of binary temporal relations among the intervals over the branching-time model. This technique has been applied with success to models of intervals over linear time by Allen and others, and is of cubic-time complexity. To extend it to branding-time models, it is necessary to calculate compositions of the relations; thus, the table of compositions for the 'atomic' relations is computed, enabling the rapid determination of the composition of arbitrary relations, expressed as disjunctions or unions of the atomic relations.

  20. Time-measurement-regulating peptide PIN may alter a timer conformation of Time Interval Measuring Enzyme (TIME).

    PubMed

    Ti, Xiaonan; Tani, Naoki; Isobe, Minoru; Kai, Hidenori

    2006-05-01

    The TIME (Time Interval Measuring Enzyme) ATPase measures time intervals in accordance with diapause development, which indispensably requires cold for resumption of embryonic development in the silkworm (Bombyx mori). The PIN (Peptidyl Inhibitory Needle) peptide regulates the time measurement function of TIME. In the present study we investigated the interaction between TIME and PIN in order to address the mechanism of diapause development. When TIME was isolated from eggs later than 12 days after oviposition, transient bursts of ATPase activity occurred 18h after isolation of TIME, and the younger the eggs and pupal ovaries from which TIME was isolated, the earlier the bursts of ATPase activity appeared. However, no interval-timer activation of ATPase occurred in ovaries earlier than 6 days after pupation. Similar patterns of ATPase activity occurred in test tubes after mixing TIME with PIN. The shorter the time PIN was mixed with TIME, the earlier the ATPase activity appeared. The timer may be built into the protein conformation of TIME, and PIN (which is present in ovaries beginning 6 days after pupation) appears able to alter this timer conformation through pupal stages to laid eggs. We discuss the possible mechanism of diapause development in relation to the timer mechanism of TIME.

  1. Proceedings of the Fourth Precise Time and Time Interval Planning Meeting

    NASA Technical Reports Server (NTRS)

    Acrivos, H. N. (Compiler); Wardrip, S. C. (Compiler)

    1972-01-01

    The proceedings of a conference on Precise Time and Time Interval Planning are presented. The subjects discussed include the following: (1) satellite timing techniques, precision frequency sources, and very long baseline interferometry, (2) frequency stabilities and communications, and (3) very low frequency and ultrahigh frequency propagation and use. Emphasis is placed on the accuracy of time discrimination obtained with time measuring equipment and specific applications of time measurement to military operations and civilian research projects.

  2. The Behavioral Economics of Choice and Interval Timing

    ERIC Educational Resources Information Center

    Jozefowiez, J.; Staddon, J. E. R.; Cerutti, D. T.

    2009-01-01

    The authors propose a simple behavioral economic model (BEM) describing how reinforcement and interval timing interact. The model assumes a Weber-law-compliant logarithmic representation of time. Associated with each represented time value are the payoffs that have been obtained for each possible response. At a given real time, the response with…

  3. The diagnostic value of narrow-band imaging for early and invasive lung cancer: a meta-analysis.

    PubMed

    Zhu, Juanjuan; Li, Wei; Zhou, Jihong; Chen, Yuqing; Zhao, Chenling; Zhang, Ting; Peng, Wenjia; Wang, Xiaojing

    2017-07-01

    This study aimed to compare the ability of narrow-band imaging to detect early and invasive lung cancer with that of conventional pathological analysis and white-light bronchoscopy. We searched the PubMed, EMBASE, Sinomed, and China National Knowledge Infrastructure databases for relevant studies. Meta-disc software was used to perform data analysis, meta-regression analysis, sensitivity analysis, and heterogeneity testing, and STATA software was used to determine if publication bias was present, as well as to calculate the relative risks for the sensitivity and specificity of narrow-band imaging vs those of white-light bronchoscopy for the detection of early and invasive lung cancer. A random-effects model was used to assess the diagnostic efficacy of the above modalities in cases in which a high degree of between-study heterogeneity was noted with respect to their diagnostic efficacies. The database search identified six studies including 578 patients. The pooled sensitivity and specificity of narrow-band imaging were 86% (95% confidence interval: 83-88%) and 81% (95% confidence interval: 77-84%), respectively, and the pooled sensitivity and specificity of white-light bronchoscopy were 70% (95% confidence interval: 66-74%) and 66% (95% confidence interval: 62-70%), respectively. The pooled relative risks for the sensitivity and specificity of narrow-band imaging vs the sensitivity and specificity of white-light bronchoscopy for the detection of early and invasive lung cancer were 1.33 (95% confidence interval: 1.07-1.67) and 1.09 (95% confidence interval: 0.84-1.42), respectively, and sensitivity analysis showed that narrow-band imaging exhibited good diagnostic efficacy with respect to detecting early and invasive lung cancer and that the results of the study were stable. Narrow-band imaging was superior to white light bronchoscopy with respect to detecting early and invasive lung cancer; however, the specificities of the two modalities did not differ

  4. Assessment of cardiac time intervals using high temporal resolution real-time spiral phase contrast with UNFOLDed-SENSE.

    PubMed

    Kowalik, Grzegorz T; Knight, Daniel S; Steeden, Jennifer A; Tann, Oliver; Odille, Freddy; Atkinson, David; Taylor, Andrew; Muthurangu, Vivek

    2015-02-01

    To develop a real-time phase contrast MR sequence with high enough temporal resolution to assess cardiac time intervals. The sequence utilized spiral trajectories with an acquisition strategy that allowed a combination of temporal encoding (Unaliasing by fourier-encoding the overlaps using the temporal dimension; UNFOLD) and parallel imaging (Sensitivity encoding; SENSE) to be used (UNFOLDed-SENSE). An in silico experiment was performed to determine the optimum UNFOLD filter. In vitro experiments were carried out to validate the accuracy of time intervals calculation and peak mean velocity quantification. In addition, 15 healthy volunteers were imaged with the new sequence, and cardiac time intervals were compared to reference standard Doppler echocardiography measures. For comparison, in silico, in vitro, and in vivo experiments were also carried out using sliding window reconstructions. The in vitro experiments demonstrated good agreement between real-time spiral UNFOLDed-SENSE phase contrast MR and the reference standard measurements of velocity and time intervals. The protocol was successfully performed in all volunteers. Subsequent measurement of time intervals produced values in keeping with literature values and good agreement with the gold standard echocardiography. Importantly, the proposed UNFOLDed-SENSE sequence outperformed the sliding window reconstructions. Cardiac time intervals can be successfully assessed with UNFOLDed-SENSE real-time spiral phase contrast. Real-time MR assessment of cardiac time intervals may be beneficial in assessment of patients with cardiac conditions such as diastolic dysfunction. © 2014 Wiley Periodicals, Inc.

  5. The Narrow-Line Region of Narrow-Line Seyfert 1 Galaxies

    NASA Astrophysics Data System (ADS)

    Rodríguez-Ardila, A.; Binette, Luc; Pastoriza, Miriani G.; Donzelli, Carlos J.

    2000-08-01

    This work studies the optical emission-line properties and physical conditions of the narrow-line region (NLR) of seven narrow-line Seyfert 1 galaxies (NLS1's) for which high signal-to-noise ratio spectroscopic observations were available. The resolution is 340 km s-1 (at Hα) over the wavelength interval 3700-9500 Å, enabling us to separate the broad and narrow components of the permitted emission lines. Our results show that the flux carried out by the narrow component of Hβ is, on average, 50% of the total line flux. As a result, the [O III] λ5007/Hβ ratio emitted in the NLR varies from 1 to 5, instead of the universally adopted value of 10. This has strong implications for the required spectral energy distribution that ionizes the NLR gas. Photoionization models that consider a NLR composed of a combination of matter-bounded and ionization-bounded clouds are successful at explaining the low [O III] λ5007/Hβ ratio and the weakness of low-ionization lines of NLS1's. Variation of the relative proportion of these two type of clouds nicely reproduces the dispersion of narrow-line ratios found among the NLS1 sample. Assuming similar physical model parameters of both NLS1's and the normal Seyfert 1 galaxy NGC 5548, we show that the observed differences of emission-line ratios between these two groups of galaxies can be explained, to a first approximation, in terms of the shape of the input ionizing continuum. Narrow emission-line ratios of NLS1's are better reproduced by a steep power-law continuum in the EUV-soft X-ray region, with spectral index α~-2. Flatter spectral indices (α~-1.5) match the observed line ratios of NGC 5548 but are unable to provide a good match to the NLS1 ratios. This result is consistent with ROSAT observations of NLS1's, which show that these objects are characterized by steeper power-law indices than those of Seyfert 1 galaxies with strong broad optical lines. Based on observations made at CASLEO. Complejo Astronómico El Leoncito

  6. Computer-aided diagnosis of colorectal polyp histology by using a real-time image recognition system and narrow-band imaging magnifying colonoscopy.

    PubMed

    Kominami, Yoko; Yoshida, Shigeto; Tanaka, Shinji; Sanomura, Yoji; Hirakawa, Tsubasa; Raytchev, Bisser; Tamaki, Toru; Koide, Tetsusi; Kaneda, Kazufumi; Chayama, Kazuaki

    2016-03-01

    It is necessary to establish cost-effective examinations and treatments for diminutive colorectal tumors that consider the treatment risk and surveillance interval after treatment. The Preservation and Incorporation of Valuable Endoscopic Innovations (PIVI) committee of the American Society for Gastrointestinal Endoscopy published a statement recommending the establishment of endoscopic techniques that practice the resect and discard strategy. The aims of this study were to evaluate whether our newly developed real-time image recognition system can predict histologic diagnoses of colorectal lesions depicted on narrow-band imaging and to satisfy some problems with the PIVI recommendations. We enrolled 41 patients who had undergone endoscopic resection of 118 colorectal lesions (45 nonneoplastic lesions and 73 neoplastic lesions). We compared the results of real-time image recognition system analysis with that of narrow-band imaging diagnosis and evaluated the correlation between image analysis and the pathological results. Concordance between the endoscopic diagnosis and diagnosis by a real-time image recognition system with a support vector machine output value was 97.5% (115/118). Accuracy between the histologic findings of diminutive colorectal lesions (polyps) and diagnosis by a real-time image recognition system with a support vector machine output value was 93.2% (sensitivity, 93.0%; specificity, 93.3%; positive predictive value (PPV), 93.0%; and negative predictive value, 93.3%). Although further investigation is necessary to establish our computer-aided diagnosis system, this real-time image recognition system may satisfy the PIVI recommendations and be useful for predicting the histology of colorectal tumors. Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  7. MEASUREMENT OF TIME INTERVALS FOR TIME CORRELATED RADIOACTIVE DECAY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lindeman, H.; Mornel, E.; Galil, U.

    1960-11-01

    The distribution of time intervals between successive counts was measured for radioactive decay in the thorium series. The measurements showed that the classical Marsden-Barratt law does not apply to this case of timecorrelated decay. They appeared, however, to be in agreement with the theory of Lindeman-Rosen, taking into account the fact that the counter receives only the radiation emitted in a solid angle near to 2 pi . (auth)

  8. Outcome-Dependent Sampling with Interval-Censored Failure Time Data

    PubMed Central

    Zhou, Qingning; Cai, Jianwen; Zhou, Haibo

    2017-01-01

    Summary Epidemiologic studies and disease prevention trials often seek to relate an exposure variable to a failure time that suffers from interval-censoring. When the failure rate is low and the time intervals are wide, a large cohort is often required so as to yield reliable precision on the exposure-failure-time relationship. However, large cohort studies with simple random sampling could be prohibitive for investigators with a limited budget, especially when the exposure variables are expensive to obtain. Alternative cost-effective sampling designs and inference procedures are therefore desirable. We propose an outcome-dependent sampling (ODS) design with interval-censored failure time data, where we enrich the observed sample by selectively including certain more informative failure subjects. We develop a novel sieve semiparametric maximum empirical likelihood approach for fitting the proportional hazards model to data from the proposed interval-censoring ODS design. This approach employs the empirical likelihood and sieve methods to deal with the infinite-dimensional nuisance parameters, which greatly reduces the dimensionality of the estimation problem and eases the computation difficulty. The consistency and asymptotic normality of the resulting regression parameter estimator are established. The results from our extensive simulation study show that the proposed design and method works well for practical situations and is more efficient than the alternative designs and competing approaches. An example from the Atherosclerosis Risk in Communities (ARIC) study is provided for illustration. PMID:28771664

  9. Systolic time interval data acquisition system. Specialized cardiovascular studies

    NASA Technical Reports Server (NTRS)

    Baker, J. T.

    1976-01-01

    The development of a data acquisition system for noninvasive measurement of systolic time intervals is described. R-R interval from the ECG determines instantaneous heart rate prior to the beat to be measured. Total electromechanical systole (Q-S2) is measured from the onset of the ECG Q-wave to the onset of the second heart sound (S2). Ejection time (ET or LVET) is measured from the onset of carotid upstroke to the incisure. Pre-ejection period (PEP) is computed by subtracting ET from Q-S2. PEP/ET ratio is computed directly.

  10. The 26th Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting

    NASA Technical Reports Server (NTRS)

    Sydnor, Richard (Editor)

    1995-01-01

    This document is a compilation of technical papers presented at the 26th Annual PTTI Applications and Planning Meeting. Papers are in the following categories: (1) Recent developments in rubidium, cesium, and hydrogen-based frequency standards, and in cryogenic and trapped-ion technology; (2) International and transnational applications of Precise Time and Time Interval technology with emphasis on satellite laser tracking, GLONASS timing, intercomparison of national time scales and international telecommunications; (3) Applications of Precise Time and Time Interval technology to the telecommunications, power distribution, platform positioning, and geophysical survey industries; (4) Applications of PTTI technology to evolving military communications and navigation systems; and (5) Dissemination of precise time and frequency by means of GPS, GLONASS, MILSTAR, LORAN, and synchronous communications satellites.

  11. Interval timing under a behavioral microscope: Dissociating motivational and timing processes in fixed-interval performance.

    PubMed

    Daniels, Carter W; Sanabria, Federico

    2017-03-01

    The distribution of latencies and interresponse times (IRTs) of rats was compared between two fixed-interval (FI) schedules of food reinforcement (FI 30 s and FI 90 s), and between two levels of food deprivation. Computational modeling revealed that latencies and IRTs were well described by mixture probability distributions embodying two-state Markov chains. Analysis of these models revealed that only a subset of latencies is sensitive to the periodicity of reinforcement, and prefeeding only reduces the size of this subset. The distribution of IRTs suggests that behavior in FI schedules is organized in bouts that lengthen and ramp up in frequency with proximity to reinforcement. Prefeeding slowed down the lengthening of bouts and increased the time between bouts. When concatenated, latency and IRT models adequately reproduced sigmoidal FI response functions. These findings suggest that behavior in FI schedules fluctuates in and out of schedule control; an account of such fluctuation suggests that timing and motivation are dissociable components of FI performance. These mixture-distribution models also provide novel insights on the motivational, associative, and timing processes expressed in FI performance. These processes may be obscured, however, when performance in timing tasks is analyzed in terms of mean response rates.

  12. Optical timing receiver for the NASA laser ranging system. Part 2: High precision time interval digitizer

    NASA Technical Reports Server (NTRS)

    Leskovar, B.; Turko, B.

    1977-01-01

    The development of a high precision time interval digitizer is described. The time digitizer is a 10 psec resolution stop watch covering a range of up to 340 msec. The measured time interval is determined as a separation between leading edges of a pair of pulses applied externally to the start input and the stop input of the digitizer. Employing an interpolation techniques and a 50 MHz high precision master oscillator, the equivalent of a 100 GHz clock frequency standard is achieved. Absolute accuracy and stability of the digitizer are determined by the external 50 MHz master oscillator, which serves as a standard time marker. The start and stop pulses are fast 1 nsec rise time signals, according to the Nuclear Instrument means of tunnel diode discriminators. Firing level of the discriminator define start and stop points between which the time interval is digitized.

  13. Fixed-interval matching-to-sample: intermatching time and intermatching error runs1

    PubMed Central

    Nelson, Thomas D.

    1978-01-01

    Four pigeons were trained on a matching-to-sample task in which reinforcers followed either the first matching response (fixed interval) or the fifth matching response (tandem fixed-interval fixed-ratio) that occurred 80 seconds or longer after the last reinforcement. Relative frequency distributions of the matching-to-sample responses that concluded intermatching times and runs of mismatches (intermatching error runs) were computed for the final matching responses directly followed by grain access and also for the three matching responses immediately preceding the final match. Comparison of these two distributions showed that the fixed-interval schedule arranged for the preferential reinforcement of matches concluding relatively extended intermatching times and runs of mismatches. Differences in matching accuracy and rate during the fixed interval, compared to the tandem fixed-interval fixed-ratio, suggested that reinforcers following matches concluding various intermatching times and runs of mismatches influenced the rate and accuracy of the last few matches before grain access, but did not control rate and accuracy throughout the entire fixed-interval period. PMID:16812032

  14. Analysis of single ion channel data incorporating time-interval omission and sampling

    PubMed Central

    The, Yu-Kai; Timmer, Jens

    2005-01-01

    Hidden Markov models are widely used to describe single channel currents from patch-clamp experiments. The inevitable anti-aliasing filter limits the time resolution of the measurements and therefore the standard hidden Markov model is not adequate anymore. The notion of time-interval omission has been introduced where brief events are not detected. The developed, exact solutions to this problem do not take into account that the measured intervals are limited by the sampling time. In this case the dead-time that specifies the minimal detectable interval length is not defined unambiguously. We show that a wrong choice of the dead-time leads to considerably biased estimates and present the appropriate equations to describe sampled data. PMID:16849220

  15. Factors influencing pre-hospital care time intervals in Iran: a qualitative study.

    PubMed

    Khorasani-Zavareh, Davoud; Mohammadi, Reza; Bohm, Katarina

    2018-06-23

    Pre-hospital time management provides better access to victims of road traffic crashes (RTCs) and can help minimize preventable deaths, injuries and disabilities. While most studies have been focused on measuring various time intervals in the pre-hospital phase, to our best knowledge there is no study exploring the barriers and facilitators that affects these various intervals qualitatively. The present study aimed to explore factors affecting various time intervals relating to road traffic incidents in the pre-hospital phase and provides suggestions for improvements in Iran. The study was conducted during 2013-2014 at both the national and local level in Iran. Overall, 18 face-to-face interviews with emergency medical services (EMS) personnel were used for data collection. Qualitative content analysis was employed to analyze the data. The most important barriers in relation to pre-hospital intervals were related to the manner of cooperation by members of the public with the EMS and their involvement at the crash scene, as well as to pre-hospital system factors, including the number and location of EMS facilities, type and number of ambulances and manpower. These factors usually affect how rapidly the EMS can arrive at the scene of the crash and how quickly victims can be transferred to hospital. These two categories have six main themes: notification interval; activation interval; response interval; on-scene interval; transport interval; and delivery interval. Despite more focus on physical resources, cooperation from members of the public needs to be taken in account in order to achieve better pre-hospital management of the various intervals, possibly through the use of public education campaigns.

  16. Interval Timing Is Preserved Despite Circadian Desynchrony in Rats: Constant Light and Heavy Water Studies.

    PubMed

    Petersen, Christian C; Mistlberger, Ralph E

    2017-08-01

    The mechanisms that enable mammals to time events that recur at 24-h intervals (circadian timing) and at arbitrary intervals in the seconds-to-minutes range (interval timing) are thought to be distinct at the computational and neurobiological levels. Recent evidence that disruption of circadian rhythmicity by constant light (LL) abolishes interval timing in mice challenges this assumption and suggests a critical role for circadian clocks in short interval timing. We sought to confirm and extend this finding by examining interval timing in rats in which circadian rhythmicity was disrupted by long-term exposure to LL or by chronic intake of 25% D 2 O. Adult, male Sprague-Dawley rats were housed in a light-dark (LD) cycle or in LL until free-running circadian rhythmicity was markedly disrupted or abolished. The rats were then trained and tested on 15- and 30-sec peak-interval procedures, with water restriction used to motivate task performance. Interval timing was found to be unimpaired in LL rats, but a weak circadian activity rhythm was apparently rescued by the training procedure, possibly due to binge feeding that occurred during the 15-min water access period that followed training each day. A second group of rats in LL were therefore restricted to 6 daily meals scheduled at 4-h intervals. Despite a complete absence of circadian rhythmicity in this group, interval timing was again unaffected. To eliminate all possible temporal cues, we tested a third group of rats in LL by using a pseudo-randomized schedule. Again, interval timing remained accurate. Finally, rats tested in LD received 25% D 2 O in place of drinking water. This markedly lengthened the circadian period and caused a failure of LD entrainment but did not disrupt interval timing. These results indicate that interval timing in rats is resistant to disruption by manipulations of circadian timekeeping previously shown to impair interval timing in mice.

  17. Reaction time in pilots during intervals of high sustained g.

    PubMed

    Truszczynski, Olaf; Lewkowicz, Rafal; Wojtkowiak, Mieczyslaw; Biernacki, Marcin P

    2014-11-01

    An important problem for pilots is visual disturbances occurring under +Gz acceleration. Assessment of the degree of intensification of these disturbances is generally accepted as the acceleration tolerance level (ATL) criterion determined in human centrifuges. The aim of this research was to evaluate the visual-motor responses of pilots during rapidly increasing acceleration contained in cyclic intervals of +6 Gz to the maximum ATL. The study involved 40 male pilots ages 32-41 yr. The task was a quick and faultless response to the light stimuli presented on a light bar during exposure to acceleration until reaching the ATL. Simple response time (SRT) measurements were performed using a visual-motor analysis system throughout the exposures which allowed assessment of a pilot's ATL. There were 29 pilots who tolerated the initial phase of interval acceleration and achieved +6 Gz, completing the test at ATL. Relative to the control measurements, the obtained results indicate a significant effect of the applied acceleration on response time. SRT during +6 Gz exposure was not significantly longer compared with the reaction time between each of the intervals. SRT and erroneous reactions indicated no statistically significant differences between the "lower" and "higher" ATL groups. SRT measurements over the +6-Gz exposure intervals did not vary between "lower" and "higher" ATL groups and, therefore, are not useful in predicting pilot performance. The gradual exposure to the maximum value of +6 Gz with exposure to the first three intervals on the +6-Gz plateau effectively differentiated pilots.

  18. Why noise is useful in functional and neural mechanisms of interval timing?

    PubMed Central

    2013-01-01

    Background The ability to estimate durations in the seconds-to-minutes range - interval timing - is essential for survival, adaptation and its impairment leads to severe cognitive and/or motor dysfunctions. The response rate near a memorized duration has a Gaussian shape centered on the to-be-timed interval (criterion time). The width of the Gaussian-like distribution of responses increases linearly with the criterion time, i.e., interval timing obeys the scalar property. Results We presented analytical and numerical results based on the striatal beat frequency (SBF) model showing that parameter variability (noise) mimics behavioral data. A key functional block of the SBF model is the set of oscillators that provide the time base for the entire timing network. The implementation of the oscillators block as simplified phase (cosine) oscillators has the additional advantage that is analytically tractable. We also checked numerically that the scalar property emerges in the presence of memory variability by using biophysically realistic Morris-Lecar oscillators. First, we predicted analytically and tested numerically that in a noise-free SBF model the output function could be approximated by a Gaussian. However, in a noise-free SBF model the width of the Gaussian envelope is independent of the criterion time, which violates the scalar property. We showed analytically and verified numerically that small fluctuations of the memorized criterion time leads to scalar property of interval timing. Conclusions Noise is ubiquitous in the form of small fluctuations of intrinsic frequencies of the neural oscillators, the errors in recording/retrieving stored information related to criterion time, fluctuation in neurotransmitters’ concentration, etc. Our model suggests that the biological noise plays an essential functional role in the SBF interval timing. PMID:23924391

  19. More accurate, calibrated bootstrap confidence intervals for correlating two autocorrelated climate time series

    NASA Astrophysics Data System (ADS)

    Olafsdottir, Kristin B.; Mudelsee, Manfred

    2013-04-01

    Estimation of the Pearson's correlation coefficient between two time series to evaluate the influences of one time depended variable on another is one of the most often used statistical method in climate sciences. Various methods are used to estimate confidence interval to support the correlation point estimate. Many of them make strong mathematical assumptions regarding distributional shape and serial correlation, which are rarely met. More robust statistical methods are needed to increase the accuracy of the confidence intervals. Bootstrap confidence intervals are estimated in the Fortran 90 program PearsonT (Mudelsee, 2003), where the main intention was to get an accurate confidence interval for correlation coefficient between two time series by taking the serial dependence of the process that generated the data into account. However, Monte Carlo experiments show that the coverage accuracy for smaller data sizes can be improved. Here we adapt the PearsonT program into a new version called PearsonT3, by calibrating the confidence interval to increase the coverage accuracy. Calibration is a bootstrap resampling technique, which basically performs a second bootstrap loop or resamples from the bootstrap resamples. It offers, like the non-calibrated bootstrap confidence intervals, robustness against the data distribution. Pairwise moving block bootstrap is used to preserve the serial correlation of both time series. The calibration is applied to standard error based bootstrap Student's t confidence intervals. The performances of the calibrated confidence intervals are examined with Monte Carlo simulations, and compared with the performances of confidence intervals without calibration, that is, PearsonT. The coverage accuracy is evidently better for the calibrated confidence intervals where the coverage error is acceptably small (i.e., within a few percentage points) already for data sizes as small as 20. One form of climate time series is output from numerical models

  20. Time-variant random interval natural frequency analysis of structures

    NASA Astrophysics Data System (ADS)

    Wu, Binhua; Wu, Di; Gao, Wei; Song, Chongmin

    2018-02-01

    This paper presents a new robust method namely, unified interval Chebyshev-based random perturbation method, to tackle hybrid random interval structural natural frequency problem. In the proposed approach, random perturbation method is implemented to furnish the statistical features (i.e., mean and standard deviation) and Chebyshev surrogate model strategy is incorporated to formulate the statistical information of natural frequency with regards to the interval inputs. The comprehensive analysis framework combines the superiority of both methods in a way that computational cost is dramatically reduced. This presented method is thus capable of investigating the day-to-day based time-variant natural frequency of structures accurately and efficiently under concrete intrinsic creep effect with probabilistic and interval uncertain variables. The extreme bounds of the mean and standard deviation of natural frequency are captured through the embedded optimization strategy within the analysis procedure. Three particularly motivated numerical examples with progressive relationship in perspective of both structure type and uncertainty variables are demonstrated to justify the computational applicability, accuracy and efficiency of the proposed method.

  1. Interval Timing Deficits Assessed by Time Reproduction Dual Tasks as Cognitive Endophenotypes for Attention-Deficit/Hyperactivity Disorder

    PubMed Central

    Hwang-Gu, Shoou-Lian; Gau, Susan Shur-Fen

    2015-01-01

    The literature has suggested timing processing as a potential endophenotype for attention deficit/hyperactivity disorder (ADHD); however, whether the subjective internal clock speed presented by verbal estimation and limited attention capacity presented by time reproduction could be endophenotypes for ADHD is still unknown. We assessed 223 youths with DSM-IV ADHD (age range: 10-17 years), 105 unaffected siblings, and 84 typically developing (TD) youths using psychiatric interviews, intelligence tests, verbal estimation and time reproduction tasks (single task and simple and difficult dual tasks) at 5-second, 12-second, and 17-second intervals. We found that youths with ADHD tended to overestimate time in verbal estimation more than their unaffected siblings and TD youths, implying that fast subjective internal clock speed might be a characteristic of ADHD, rather than an endophenotype for ADHD. Youths with ADHD and their unaffected siblings were less precise in time reproduction dual tasks than TD youths. The magnitude of estimated errors in time reproduction was greater in youths with ADHD and their unaffected siblings than in TD youths, with an increased time interval at the 17-second interval and with increased task demands on both simple and difficult dual tasks versus the single task. Increased impaired time reproduction in dual tasks with increased intervals and task demands were shown in youths with ADHD and their unaffected siblings, suggesting that time reproduction deficits explained by limited attention capacity might be a useful endophenotype of ADHD. PMID:25992899

  2. Investigations of timing during the schedule and reinforcement intervals with wheel-running reinforcement.

    PubMed

    Belke, Terry W; Christie-Fougere, Melissa M

    2006-11-01

    Across two experiments, a peak procedure was used to assess the timing of the onset and offset of an opportunity to run as a reinforcer. The first experiment investigated the effect of reinforcer duration on temporal discrimination of the onset of the reinforcement interval. Three male Wistar rats were exposed to fixed-interval (FI) 30-s schedules of wheel-running reinforcement and the duration of the opportunity to run was varied across values of 15, 30, and 60s. Each session consisted of 50 reinforcers and 10 probe trials. Results showed that as reinforcer duration increased, the percentage of postreinforcement pauses longer than the 30-s schedule interval increased. On probe trials, peak response rates occurred near the time of reinforcer delivery and peak times varied with reinforcer duration. In a second experiment, seven female Long-Evans rats were exposed to FI 30-s schedules leading to 30-s opportunities to run. Timing of the onset and offset of the reinforcement period was assessed by probe trials during the schedule interval and during the reinforcement interval in separate conditions. The results provided evidence of timing of the onset, but not the offset of the wheel-running reinforcement period. Further research is required to assess if timing occurs during a wheel-running reinforcement period.

  3. Infinite time interval backward stochastic differential equations with continuous coefficients.

    PubMed

    Zong, Zhaojun; Hu, Feng

    2016-01-01

    In this paper, we study the existence theorem for [Formula: see text] [Formula: see text] solutions to a class of 1-dimensional infinite time interval backward stochastic differential equations (BSDEs) under the conditions that the coefficients are continuous and have linear growths. We also obtain the existence of a minimal solution. Furthermore, we study the existence and uniqueness theorem for [Formula: see text] [Formula: see text] solutions of infinite time interval BSDEs with non-uniformly Lipschitz coefficients. It should be pointed out that the assumptions of this result is weaker than that of Theorem 3.1 in Zong (Turkish J Math 37:704-718, 2013).

  4. Searching for Variability of NV Intrinsic Narrow Absorption Line Systems

    NASA Astrophysics Data System (ADS)

    Rodruck, Michael; Charlton, Jane; Ganguly, Rajib

    2018-01-01

    The majority of quasar absorption line systems with NV detected are found within the associated region (within 5000 km/s of the quasar redshift) and many/most are believed to be related to the quasar accretion disk wind or outflows. The most definite evidence that these NV absorbers are "intrinsic" is partial covering of the quasar continuum source and/or broad line region. Over 75 quasars containing NV narrow absorption lines have observations obtained at different times with the Keck/HIRES and the VLT/UVES spectrographs at high resolution. The interval between these observations range from months to a decade in the quasar rest frame. While variability is common for intrinsic broad and mini-broad absorption lines, intrinsic narrow absorption lines have been found to be less likely to vary, though systematic studies with large, high quality datasets have been limited. The variability timescales are useful for deriving gas densities and thus the distances from the central engines. This is important in mapping the quasar surroundings, understanding the accretion disk wind mechanism, and assessing the effect the wind has on the galaxy surroundings. We report on the results of a systematic study of variability of NV NALs, exploiting the overlap of targets for observations in the archives of Keck and VLT, and discuss the consequences for interpretation of the origin of intrinsic narrow absorption lines.

  5. Sleep-dependent consolidation benefits fast transfer of time interval training.

    PubMed

    Chen, Lihan; Guo, Lu; Bao, Ming

    2017-03-01

    Previous study has shown that short training (15 min) for explicitly discriminating temporal intervals between two paired auditory beeps, or between two paired tactile taps, can significantly improve observers' ability to classify the perceptual states of visual Ternus apparent motion while the training of task-irrelevant sensory properties did not help to improve visual timing (Chen and Zhou in Exp Brain Res 232(6):1855-1864, 2014). The present study examined the role of 'consolidation' after training of temporal task-irrelevant properties, or whether a pure delay (i.e., blank consolidation) following pretest of the target task would give rise to improved ability of visual interval timing, typified in visual Ternus display. A procedure of pretest-training-posttest was adopted, with the probe of discriminating Ternus apparent motion. The extended implicit training of timing in which the time intervals between paired auditory beeps or paired tactile taps were manipulated but the task was discrimination of the auditory pitches or tactile intensities, did not lead to the training benefits (Exps 1 and 3); however, a delay of 24 h after implicit training of timing, including solving 'Sudoku puzzles,' made the otherwise absent training benefits observable (Exps 2, 4, 5 and 6). The above improvements in performance were not due to a practice effect of Ternus motion (Exp 7). A general 'blank' consolidation period of 24 h also made improvements of visual timing observable (Exp 8). Taken together, the current findings indicated that sleep-dependent consolidation imposed a general effect, by potentially triggering and maintaining neuroplastic changes in the intrinsic (timing) network to enhance the ability of time perception.

  6. Evaluating Protocol Lifecycle Time Intervals in HIV/AIDS Clinical Trials

    PubMed Central

    Schouten, Jeffrey T.; Dixon, Dennis; Varghese, Suresh; Cope, Marie T.; Marci, Joe; Kagan, Jonathan M.

    2014-01-01

    Background Identifying efficacious interventions for the prevention and treatment of human diseases depends on the efficient development and implementation of controlled clinical trials. Essential to reducing the time and burden of completing the clinical trial lifecycle is determining which aspects take the longest, delay other stages, and may lead to better resource utilization without diminishing scientific quality, safety, or the protection of human subjects. Purpose In this study we modeled time-to-event data to explore relationships between clinical trial protocol development and implementation times, as well as identify potential correlates of prolonged development and implementation. Methods We obtained time interval and participant accrual data from 111 interventional clinical trials initiated between 2006 and 2011 by NIH’s HIV/AIDS Clinical Trials Networks. We determined the time (in days) required to complete defined phases of clinical trial protocol development and implementation. Kaplan-Meier estimates were used to assess the rates at which protocols reached specified terminal events, stratified by study purpose (therapeutic, prevention) and phase group (pilot/phase I, phase II, and phase III/ IV). We also examined several potential correlates to prolonged development and implementation intervals. Results Even though phase grouping did not determine development or implementation times of either therapeutic or prevention studies, overall we observed wide variation in protocol development times. Moreover, we detected a trend toward phase III/IV therapeutic protocols exhibiting longer developmental (median 2 ½ years) and implementation times (>3years). We also found that protocols exceeding the median number of days for completing the development interval had significantly longer implementation. Limitations The use of a relatively small set of protocols may have limited our ability to detect differences across phase groupings. Some timing effects

  7. Reduction of timing jitter and intensity noise in normal-dispersion passively mode-locked fiber lasers by narrow band-pass filtering.

    PubMed

    Qin, Peng; Song, Youjian; Kim, Hyoji; Shin, Junho; Kwon, Dohyeon; Hu, Minglie; Wang, Chingyue; Kim, Jungwon

    2014-11-17

    Fiber lasers mode-locked with normal cavity dispersion have recently attracted great attention due to large output pulse energy and femtosecond pulse duration. Here we accurately characterized the timing jitter of normal-dispersion fiber lasers using a balanced cross-correlation method. The timing jitter characterization experiments show that the timing jitter of normal-dispersion mode-locked fiber lasers can be significantly reduced by using narrow band-pass filtering (e.g., 7-nm bandwidth filtering in this work). We further identify that the timing jitter of the fiber laser is confined in a limited range, which is almost independent of cavity dispersion map due to the amplifier-similariton formation by insertion of the narrow bandpass filter. The lowest observed timing jitter reaches 0.57 fs (rms) integrated from 10 kHz to 10 MHz Fourier frequency. The rms relative intensity noise (RIN) is also reduced from 0.37% to 0.02% (integrated from 1 kHz to 5 MHz Fourier frequency) by the insertion of narrow band-pass filter.

  8. Introduction to Sample Size Choice for Confidence Intervals Based on "t" Statistics

    ERIC Educational Resources Information Center

    Liu, Xiaofeng Steven; Loudermilk, Brandon; Simpson, Thomas

    2014-01-01

    Sample size can be chosen to achieve a specified width in a confidence interval. The probability of obtaining a narrow width given that the confidence interval includes the population parameter is defined as the power of the confidence interval, a concept unfamiliar to many practitioners. This article shows how to utilize the Statistical Analysis…

  9. [Estimation of the atrioventricular time interval by pulse Doppler in the normal fetal heart].

    PubMed

    Hamela-Olkowska, Anita; Dangel, Joanna

    2009-08-01

    To assess normative values of the fetal atrioventricular (AV) time interval by pulse-wave Doppler methods on 5-chamber view. Fetal echocardiography exams were performed using Acuson Sequoia 512 in 140 singleton fetuses at 18 to 40 weeks of gestation with sinus rhythm and normal cardiac and extracardiac anatomy. Pulsed Doppler derived AV intervals were measured from left ventricular inflow/outflow view using transabdominal convex 3.5-6 MHz probe. The values of AV time interval ranged from 100 to 150 ms (mean 123 +/- 11.2). The AV interval was negatively correlated with the heart rhythm (p<0.001). Fetal heart rate decreased as gestation progressed (p<0.001). Thus, the AV intervals increased with the age of gestation (p=0.007). However, in the same subgroup of the fetal heart rate there was no relation between AV intervals and gestational age. Therefore, the AV intervals showed only the heart rate dependence. The 95th percentiles of AV intervals according to FHR ranged from 135 to 148 ms. 1. The AV interval duration was negatively correlated with the heart rhythm. 2. Measurement of AV time interval is easy to perform and has a good reproducibility. It may be used for the fetal heart block screening in anti-Ro and anti-La positive pregnancies. 3. Normative values established in the study may help obstetricians in assessing fetal abnormalities of the AV conduction.

  10. Dissociations between interval timing and intertemporal choice following administration of fluoxetine, cocaine, or methamphetamine

    PubMed Central

    Heilbronner, Sarah R.; Meck, Warren. H.

    2014-01-01

    The goal of our study was to characterize the relationship between intertemporal choice and interval timing, including determining how drugs that modulate brain serotonin and dopamine levels influence these two processes. In Experiment 1, rats were tested on a standard 40-s peak-interval procedure following administration of fluoxetine (3, 5, or 8 mg/kg) or vehicle to assess basic effects on interval timing. In Experiment 2, rats were tested in a novel behavioral paradigm intended to simultaneously examine interval timing and impulsivity. Rats performed a variant of the bi-peak procedure using 10-s and 40-s target durations with an additional “defection” lever that provided the possibility of a small, immediate reward. Timing functions remained relatively intact, and ‘patience’ across subjects correlated with peak times, indicating a negative relationship between ‘patience’ and clock speed. We next examined the effects of fluoxetine (5 mg/kg), cocaine (15 mg/kg), or methamphetamine (1 mg/kg) on task performance. Fluoxetine reduced impulsivity as measured by defection time without corresponding changes in clock speed. In contrast, cocaine and methamphetamine both increased impulsivity and clock speed. Thus, variations in timing may mediate intertemporal choice via dopaminergic inputs. However, a separate, serotonergic system can affect intertemporal choice without affecting interval timing directly. PMID:24135569

  11. Fault detection for discrete-time LPV systems using interval observers

    NASA Astrophysics Data System (ADS)

    Zhang, Zhi-Hui; Yang, Guang-Hong

    2017-10-01

    This paper is concerned with the fault detection (FD) problem for discrete-time linear parameter-varying systems subject to bounded disturbances. A parameter-dependent FD interval observer is designed based on parameter-dependent Lyapunov and slack matrices. The design method is presented by translating the parameter-dependent linear matrix inequalities (LMIs) into finite ones. In contrast to the existing results based on parameter-independent and diagonal Lyapunov matrices, the derived disturbance attenuation, fault sensitivity and nonnegative conditions lead to less conservative LMI characterisations. Furthermore, without the need to design the residual evaluation functions and thresholds, the residual intervals generated by the interval observers are used directly for FD decision. Finally, simulation results are presented for showing the effectiveness and superiority of the proposed method.

  12. New precession expressions, valid for long time intervals

    NASA Astrophysics Data System (ADS)

    Vondrák, J.; Capitaine, N.; Wallace, P.

    2011-10-01

    Context. The present IAU model of precession, like its predecessors, is given as a set of polynomial approximations of various precession parameters intended for high-accuracy applications over a limited time span. Earlier comparisons with numerical integrations have shown that this model is valid only for a few centuries around the basic epoch, J2000.0, while for more distant epochs it rapidly diverges from the numerical solution. In our preceding studies we also obtained preliminary developments for the precessional contribution to the motion of the equator: coordinates X,Y of the precessing pole and precession parameters ψA,ωA, suitable for use over long time intervals. Aims: The goal of the present paper is to obtain upgraded developments for various sets of precession angles that would fit modern observations near J2000.0 and at the same time fit numerical integration of the motions of solar system bodies on scales of several thousand centuries. Methods: We used the IAU 2006 solutions to represent the precession of the ecliptic and of the equator close to J2000.0 and, for more distant epochs, a numerical integration using the Mercury 6 package and solutions by Laskar et al. (1993, A&A, 270, 522) with upgraded initial conditions and constants to represent the ecliptic, and general precession and obliquity, respectively. From them, different precession parameters were calculated in the interval ± 200 millennia from J2000.0, and analytical expressions are found that provide a good fit for the whole interval. Results: Series for the various precessional parameters, comprising a cubic polynomial plus from 8 to 14 periodic terms, are derived that allow precession to be computed with an accuracy comparable to IAU 2006 around the central epoch J2000.0, a few arcseconds throughout the historical period, and a few tenths of a degree at the ends of the ± 200 millennia time span. Computer algorithms are provided that compute the ecliptic and mean equator poles and the

  13. Measuring the EMS patient access time interval and the impact of responding to high-rise buildings.

    PubMed

    Morrison, Laurie J; Angelini, Mark P; Vermeulen, Marian J; Schwartz, Brian

    2005-01-01

    To measure the patient access time interval and characterize its contribution to the total emergency medical services (EMS) response time interval; to compare the patient access time intervals for patients located three or more floors above ground with those less than three floors above or below ground, and specifically in the apartment subgroup; and to identify barriers that significantly impede EMS access to patients in high-rise apartments. An observational study of all patients treated by an emergency medical technician paramedics (EMT-P) crew was conducted using a trained independent observer to collect time intervals and identify potential barriers to access. Of 118 observed calls, 25 (21%) originated from patients three or more floors above ground. The overall median and 90th percentile (95% confidence interval) patient access time intervals were 1.61 (1.27, 1.91) and 3.47 (3.08, 4.05) minutes, respectively. The median interval was 2.73 (2.22, 3.03) minutes among calls from patients located three or more stories above ground compared with 1.25 (1.07, 1.55) minutes among those at lower levels. The patient access time interval represented 23.5% of the total EMS response time interval among calls originating less than three floors above or below ground and 32.2% of those located three or more stories above ground. The most frequently encountered barriers to access included security code entry requirements, lack of directional signs, and inability to fit the stretcher into the elevator. The patient access time interval is significantly long and represents a substantial component of the total EMS response time interval, especially among ambulance calls originating three or more floors above ground. A number of barriers appear to contribute to delayed paramedic access.

  14. Estimation of postmortem interval based on colony development time for Anoplolepsis longipes (Hymenoptera: Formicidae).

    PubMed

    Goff, M L; Win, B H

    1997-11-01

    The postmortem interval for a set of human remains discovered inside a metal tool box was estimated using the development time required for a stratiomyid fly (Diptera: Stratiomyidae), Hermetia illucens, in combination with the time required to establish a colony of the ant Anoplolepsis longipes (Hymenoptera: Formicidae) capable of producing alate (winged) reproductives. This analysis resulted in a postmortem interval estimate of 14 + months, with a period of 14-18 months being the most probable time interval. The victim had been missing for approximately 18 months.

  15. The 22nd Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting

    NASA Technical Reports Server (NTRS)

    Sydnor, Richard L. (Editor)

    1990-01-01

    Papers presented at the 22nd Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting are compiled. The following subject areas are covered: Rb, Cs, and H-based frequency standards and cryogenic and trapped-ion technology; satellite laser tracking networks, GLONASS timing, intercomparison of national time scales and international telecommunications; telecommunications, power distribution, platform positioning, and geophysical survey industries; military communications and navigation systems; and dissemination of precise time and frequency by means of GPS, GLONASS, MILSTAR, LORAN, and synchronous communication satellites.

  16. Probing interval timing with scalp-recorded electroencephalography (EEG).

    PubMed

    Ng, Kwun Kei; Penney, Trevor B

    2014-01-01

    Humans, and other animals, are able to easily learn the durations of events and the temporal relationships among them in spite of the absence of a dedicated sensory organ for time. This chapter summarizes the investigation of timing and time perception using scalp-recorded electroencephalography (EEG), a non-invasive technique that measures brain electrical potentials on a millisecond time scale. Over the past several decades, much has been learned about interval timing through the examination of the characteristic features of averaged EEG signals (i.e., event-related potentials, ERPs) elicited in timing paradigms. For example, the mismatch negativity (MMN) and omission potential (OP) have been used to study implicit and explicit timing, respectively, the P300 has been used to investigate temporal memory updating, and the contingent negative variation (CNV) has been used as an index of temporal decision making. In sum, EEG measures provide biomarkers of temporal processing that allow researchers to probe the cognitive and neural substrates underlying time perception.

  17. Dynamic response analysis of structure under time-variant interval process model

    NASA Astrophysics Data System (ADS)

    Xia, Baizhan; Qin, Yuan; Yu, Dejie; Jiang, Chao

    2016-10-01

    Due to the aggressiveness of the environmental factor, the variation of the dynamic load, the degeneration of the material property and the wear of the machine surface, parameters related with the structure are distinctly time-variant. Typical model for time-variant uncertainties is the random process model which is constructed on the basis of a large number of samples. In this work, we propose a time-variant interval process model which can be effectively used to deal with time-variant uncertainties with limit information. And then two methods are presented for the dynamic response analysis of the structure under the time-variant interval process model. The first one is the direct Monte Carlo method (DMCM) whose computational burden is relative high. The second one is the Monte Carlo method based on the Chebyshev polynomial expansion (MCM-CPE) whose computational efficiency is high. In MCM-CPE, the dynamic response of the structure is approximated by the Chebyshev polynomials which can be efficiently calculated, and then the variational range of the dynamic response is estimated according to the samples yielded by the Monte Carlo method. To solve the dependency phenomenon of the interval operation, the affine arithmetic is integrated into the Chebyshev polynomial expansion. The computational effectiveness and efficiency of MCM-CPE is verified by two numerical examples, including a spring-mass-damper system and a shell structure.

  18. Motor and Executive Control in Repetitive Timing of Brief Intervals

    ERIC Educational Resources Information Center

    Holm, Linus; Ullen, Fredrik; Madison, Guy

    2013-01-01

    We investigated the causal role of executive control functions in the production of brief time intervals by means of a concurrent task paradigm. To isolate the influence of executive functions on timing from motor coordination effects, we dissociated executive load from the number of effectors used in the dual task situation. In 3 experiments,…

  19. Semiparametric regression analysis of failure time data with dependent interval censoring.

    PubMed

    Chen, Chyong-Mei; Shen, Pao-Sheng

    2017-09-20

    Interval-censored failure-time data arise when subjects are examined or observed periodically such that the failure time of interest is not examined exactly but only known to be bracketed between two adjacent observation times. The commonly used approaches assume that the examination times and the failure time are independent or conditionally independent given covariates. In many practical applications, patients who are already in poor health or have a weak immune system before treatment usually tend to visit physicians more often after treatment than those with better health or immune system. In this situation, the visiting rate is positively correlated with the risk of failure due to the health status, which results in dependent interval-censored data. While some measurable factors affecting health status such as age, gender, and physical symptom can be included in the covariates, some health-related latent variables cannot be observed or measured. To deal with dependent interval censoring involving unobserved latent variable, we characterize the visiting/examination process as recurrent event process and propose a joint frailty model to account for the association of the failure time and visiting process. A shared gamma frailty is incorporated into the Cox model and proportional intensity model for the failure time and visiting process, respectively, in a multiplicative way. We propose a semiparametric maximum likelihood approach for estimating model parameters and show the asymptotic properties, including consistency and weak convergence. Extensive simulation studies are conducted and a data set of bladder cancer is analyzed for illustrative purposes. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  20. Neural activity related to discrimination and vocal production of consonant and dissonant musical intervals.

    PubMed

    González-García, Nadia; González, Martha A; Rendón, Pablo L

    2016-07-15

    Relationships between musical pitches are described as either consonant, when associated with a pleasant and harmonious sensation, or dissonant, when associated with an inharmonious feeling. The accurate singing of musical intervals requires communication between auditory feedback processing and vocal motor control (i.e. audio-vocal integration) to ensure that each note is produced correctly. The objective of this study is to investigate the neural mechanisms through which trained musicians produce consonant and dissonant intervals. We utilized 4 musical intervals (specifically, an octave, a major seventh, a fifth, and a tritone) as the main stimuli for auditory discrimination testing, and we used the same interval tasks to assess vocal accuracy in a group of musicians (11 subjects, all female vocal students at conservatory level). The intervals were chosen so as to test for differences in recognition and production of consonant and dissonant intervals, as well as narrow and wide intervals. The subjects were studied using fMRI during performance of the interval tasks; the control condition consisted of passive listening. Singing dissonant intervals as opposed to singing consonant intervals led to an increase in activation in several regions, most notably the primary auditory cortex, the primary somatosensory cortex, the amygdala, the left putamen, and the right insula. Singing wide intervals as opposed to singing narrow intervals resulted in the activation of the right anterior insula. Moreover, we also observed a correlation between singing in tune and brain activity in the premotor cortex, and a positive correlation between training and activation of primary somatosensory cortex, primary motor cortex, and premotor cortex during singing. When singing dissonant intervals, a higher degree of training correlated with the right thalamus and the left putamen. Our results indicate that singing dissonant intervals requires greater involvement of neural mechanisms

  1. Proceedings of the Eleventh Annual Precise Time and Time Interval (PTTI) Application and Planning Meeting. [conference

    NASA Technical Reports Server (NTRS)

    Wardrip, S. C. (Editor)

    1979-01-01

    Thirty eight papers are presented addressing various aspects of precise time and time interval applications. Areas discussed include: past accomplishments; state of the art systems; new and useful applications, procedures, and techniques; and fruitful directions for research efforts.

  2. Broad- versus Narrow-Spectrum Oral Antibiotic Transition and Outcomes in Health Care-associated Pneumonia.

    PubMed

    Buckel, Whitney R; Stenehjem, Edward; Sorensen, Jeff; Dean, Nathan; Webb, Brandon

    2017-02-01

    Guidelines recommend a switch from intravenous to oral antibiotics once patients who are hospitalized with pneumonia achieve clinical stability. However, little evidence guides the selection of an oral antibiotic for patients with health care-associated pneumonia, especially where no microbiological diagnosis is made. To compare outcomes between patients who were transitioned to broad- versus narrow-spectrum oral antibiotics after initially receiving broad-spectrum intravenous antibiotic coverage. We performed a secondary analysis of an existing database of adults with community-onset pneumonia admitted to seven Utah hospitals. We identified 220 inpatients with microbiology-negative health care-associated pneumonia from 2010 to 2012. After excluding inpatient deaths and treatment failures, 173 patients remained in which broad-spectrum intravenous antibiotics were transitioned to an oral regimen. We classified oral regimens as broad-spectrum (fluoroquinolone) versus narrow-spectrum (usually a β-lactam). We compared demographic and clinical characteristics between groups. Using a multivariable regression model, we adjusted outcomes by severity (electronically calculated CURB-65), comorbidity (Charlson Index), time to clinical stability, and length of intravenous therapy. Age, severity, comorbidity, length of intravenous therapy, and clinical response were similar between the two groups. Observed 30-day readmission (11.9 vs. 21.4%; P = 0.26) and 30-day all-cause mortality (2.3 vs. 5.3%; P = 0.68) were also similar between the narrow and broad oral antibiotic groups. In multivariable analysis, we found no statistically significant differences for adjusted odds of 30-day readmission (adjusted odds ratio, 0.56; 95% confidence interval, 0.06-5.2; P = 0.61) or 30-day all-cause mortality (adjusted odds ratio, 0.55; 95% confidence interval, 0.19-1.6; P = 0.26) between narrow and broad oral antibiotic groups. On the basis of analysis of a limited number of patients

  3. Real-Time Optical Biopsy of Colon Polyps With Narrow Band Imaging in Community Practice Does Not Yet Meet Key Thresholds for Clinical Decisions

    PubMed Central

    LADABAUM, URI; FIORITTO, ANN; MITANI, AYA; DESAI, MANISHA; KIM, JANE P.; REX, DOUGLAS K.; IMPERIALE, THOMAS; GUNARATNAM, NARESH

    2017-01-01

    BACKGROUND & AIMS Accurate optical analysis of colorectal polyps (optical biopsy) could prevent unnecessary polypectomies or allow a “resect and discard” strategy with surveillance intervals determined based on the results of the optical biopsy; this could be less expensive than histopathologic analysis of polyps. We prospectively evaluated real-time optical biopsy analysis of polyps with narrow band imaging (NBI) by community-based gastroenterologists. METHODS We first analyzed a computerized module to train gastroenterologists (N = 13) in optical biopsy skills using photographs of polyps. Then we evaluated a practice-based learning program for these gastroenterologists (n = 12) that included real-time optical analysis of polyps in vivo, comparison of optical biopsy predictions to histopathologic analysis, and ongoing feedback on performance. RESULTS Twelve of 13 subjects identified adenomas with >90% accuracy at the end of the computer study, and 3 of 12 subjects did so with accuracy ≥90% in the in vivo study. Learning curves showed considerable variation among batches of polyps. For diminutive rectosigmoid polyps assessed with high confidence at the end of the study, adenomas were identified with mean (95% confidence interval [CI]) accuracy, sensitivity, specificity, and negative predictive values of 81% (73%–89%), 85% (74%–96%), 78% (66%–92%), and 91% (86%–97%), respectively. The adjusted odds ratio for high confidence as a predictor of accuracy was 1.8 (95% CI, 1.3–2.5). The agreement between surveillance recommendations informed by high-confidence NBI analysis of diminutive polyps and results from histopathologic analysis of all polyps was 80% (95% CI, 77%–82%). CONCLUSIONS In an evaluation of real-time optical biopsy analysis of polyps with NBI, only 25% of gastroenterologists assessed polyps with ≥90% accuracy. The negative predictive value for identification of adenomas, but not the surveillance interval agreement, met the American

  4. Improved confidence intervals when the sample is counted an integer times longer than the blank.

    PubMed

    Potter, William Edward; Strzelczyk, Jadwiga Jodi

    2011-05-01

    Past computer solutions for confidence intervals in paired counting are extended to the case where the ratio of the sample count time to the blank count time is taken to be an integer, IRR. Previously, confidence intervals have been named Neyman-Pearson confidence intervals; more correctly they should have been named Neyman confidence intervals or simply confidence intervals. The technique utilized mimics a technique used by Pearson and Hartley to tabulate confidence intervals for the expected value of the discrete Poisson and Binomial distributions. The blank count and the contribution of the sample to the gross count are assumed to be Poisson distributed. The expected value of the blank count, in the sample count time, is assumed known. The net count, OC, is taken to be the gross count minus the product of IRR with the blank count. The probability density function (PDF) for the net count can be determined in a straightforward manner.

  5. The 25th Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting

    NASA Technical Reports Server (NTRS)

    Sydnor, Richard L. (Editor)

    1994-01-01

    Papers in the following categories are presented: recent developments in rubidium, cesium, and hydrogen-based frequency standards, and in cryogenic and trapped-ion technology; international and transnational applications of precise time and time interval (PTTI) technology with emphasis on satellite laser tracking networks, GLONASS timing, intercomparison of national time scales and international telecommunication; applications of PTTI technology to the telecommunications, power distribution, platform positioning, and geophysical survey industries; application of PTTI technology to evolving military communications and navigation systems; and dissemination of precise time and frequency by means of GPS, GLONASS, MILSTAR, LORAN, and synchronous communications satellites.

  6. Changes in crash risk following re-timing of traffic signal change intervals.

    PubMed

    Retting, Richard A; Chapline, Janella F; Williams, Allan F

    2002-03-01

    More than I million motor vehicle crashes occur annually at signalized intersections in the USA. The principal method used to prevent crashes associated with routine changes in signal indications is employment of a traffic signal change interval--a brief yellow and all-red period that follows the green indication. No universal practice exists for selecting the duration of change intervals, and little is known about the influence of the duration of the change interval on crash risk. The purpose of this study was to estimate potential crash effects of modifying the duration of traffic signal change intervals to conform with values associated with a proposed recommended practice published by the Institute of Transportation Engineers. A sample of 122 intersections was identified and randomly assigned to experimental and control groups. Of 51 eligible experimental sites, 40 (78%) needed signal timing changes. For the 3-year period following implementation of signal timing changes, there was an 8% reduction in reportable crashes at experimental sites relative to those occurring at control sites (P = 0.08). For injury crashes, a 12% reduction at experimental sites relative to those occurring at control sites was found (P = 0.03). Pedestrian and bicycle crashes at experimental sites decreased 37% (P = 0.03) relative to controls. Given these results and the relatively low cost of re-timing traffic signals, modifying the duration of traffic signal change intervals to conform with values associated with the Institute of Transportation Engineers' proposed recommended practice should be strongly considered by transportation agencies to reduce the frequency of urban motor vehicle crashes.

  7. Quantification of transuranic elements by time interval correlation spectroscopy of the detected neutrons

    PubMed

    Baeten; Bruggeman; Paepen; Carchon

    2000-03-01

    The non-destructive quantification of transuranic elements in nuclear waste management or in safeguards verifications is commonly performed by passive neutron assay techniques. To minimise the number of unknown sample-dependent parameters, Neutron Multiplicity Counting (NMC) is applied. We developed a new NMC-technique, called Time Interval Correlation Spectroscopy (TICS), which is based on the measurement of Rossi-alpha time interval distributions. Compared to other NMC-techniques, TICS offers several advantages.

  8. Systolic and diastolic time intervals in pulsus alternans - Significance of alternating isovolumic relaxation

    NASA Technical Reports Server (NTRS)

    Spodick, D. H.; Quarry, V. M.; Khan, A. H.

    1974-01-01

    Systolic and diastolic time intervals in 14 cardiac patients with pulsus alternans revealed significant alternation of preinjection period (PEP), isovolumic contraction time (IVCT), left ventricular ejection time (LVET), ejection time index (ETI), PEP/LVET, and carotid dD/dt with better functional values in the strong beats. Cycle length, duration of electromechanical systole (EMS) and total diastole, i.e., isovolumic relaxation period (IRP) and diastolic filling period (DFP) occurred in 7 out of 8 patients. These diastolic intervals alternated reciprocally such that the IRP of the strong beats encroached upon the DFP of the next (weak) beats.

  9. Reducing the width of confidence intervals for the difference between two population means by inverting adaptive tests.

    PubMed

    O'Gorman, Thomas W

    2018-05-01

    In the last decade, it has been shown that an adaptive testing method could be used, along with the Robbins-Monro search procedure, to obtain confidence intervals that are often narrower than traditional confidence intervals. However, these confidence interval limits require a great deal of computation and some familiarity with stochastic search methods. We propose a method for estimating the limits of confidence intervals that uses only a few tests of significance. We compare these limits to those obtained by a lengthy Robbins-Monro stochastic search and find that the proposed method is nearly as accurate as the Robbins-Monro search. Adaptive confidence intervals that are produced by the proposed method are often narrower than traditional confidence intervals when the distributions are long-tailed, skewed, or bimodal. Moreover, the proposed method of estimating confidence interval limits is easy to understand, because it is based solely on the p-values from a few tests of significance.

  10. 27th Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting

    NASA Technical Reports Server (NTRS)

    Sydnor, Richard L. (Editor)

    1996-01-01

    This document is a compilation of technical papers presented at the 27th Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting, held November 29 - December 1, 1995 at San Diego, CA. Papers are in the following categories: Recent developments in rubidium, cesium, and hydrogen-based frequency standards; and in cryogenic and trapped-ion technology; International and transnational applications of PTTI technology with emphasis on satellite laser tracking, GLONASS timing, intercomparison of national time scales and international telecommunications; Applications of PTTI technology to the telecommunications, power distribution, platform positioning, and geophysical survey industries; Applications of PTTI technology to evolving military communications and navigation systems; and Dissemination of precise time and frequency by means of Global Positioning System (GPS), Global Satellite Navigation System (GLONASS), MILSTAR, LORAN, and synchronous communications satellites.

  11. Characterization of Cardiac Time Intervals in Healthy Bonnet Macaques (Macaca radiata) by Using an Electronic Stethoscope

    PubMed Central

    Kamran, Haroon; Salciccioli, Louis; Pushilin, Sergei; Kumar, Paraag; Carter, John; Kuo, John; Novotney, Carol; Lazar, Jason M

    2011-01-01

    Nonhuman primates are used frequently in cardiovascular research. Cardiac time intervals derived by phonocardiography have long been used to assess left ventricular function. Electronic stethoscopes are simple low-cost systems that display heart sound signals. We assessed the use of an electronic stethoscope to measure cardiac time intervals in 48 healthy bonnet macaques (age, 8 ± 5 y) based on recorded heart sounds. Technically adequate recordings were obtained from all animals and required 1.5 ± 1.3 min. The following cardiac time intervals were determined by simultaneously recording acoustic and single-lead electrocardiographic data: electromechanical activation time (QS1), electromechanical systole (QS2), the time interval between the first and second heart sounds (S1S2), and the time interval between the second and first sounds (S2S1). QS2 was correlated with heart rate, mean arterial pressure, diastolic blood pressure, and left ventricular ejection time determined by using echocardiography. S1S2 correlated with heart rate, mean arterial pressure, diastolic blood pressure, left ventricular ejection time, and age. S2S1 correlated with heart rate, mean arterial pressure, diastolic blood pressure, systolic blood pressure, and left ventricular ejection time. QS1 did not correlate with any anthropometric or echocardiographic parameter. The relation S1S2/S2S1 correlated with systolic blood pressure. On multivariate analyses, heart rate was the only independent predictor of QS2, S1S2, and S2S1. In conclusion, determination of cardiac time intervals is feasible and reproducible by using an electrical stethoscope in nonhuman primates. Heart rate is a major determinant of QS2, S1S2, and S2S1 but not QS1; regression equations for reference values for cardiac time intervals in bonnet macaques are provided. PMID:21439218

  12. [Influence of age on systolic and diastolic time intervals in normal individuals].

    PubMed

    Soares-Costa, J T; Soares-Costa, T J; Santos, A J; Monteiro, A J

    1991-12-01

    To evaluate the influence of age (I) on the left ventricle (VE) systolic time intervals, the S2O interval, the pulse transmission time (TTP) and the relative amplitude of the a wave (Aa%) of the apexcardiogram (ACG) of normal individuals. 202 subjects considered as normal by clinical and electrocardiographic examinations were studied. Their age (I) was 38 +/- 13 years (average +/- 1 SD), being 125 male and 77 female. The electrocardiogram (ECG), phonocardiogram, ACG and carotid arterial pulse tracing (PC) were simultaneously recorded. The following intervals were determined: Electromechanical (IEM)--from the onset of QRS complex of the ECG to the ascending branch of the great wave of the ACG (A point); mechanical systole (SM)--from the A point of the ACG to the beginning of first high frequency vibration of the aortic component of the second heart sound (S2); ejection period (FE)--from the beginning of the anacrotic branch of the PC to the nadir of its dicrotic notch (ID); isovolumic contraction time (FIS)--subtracting FE duration to the SM duration; S2O interval--since S2 to the O point (nadir) of the ACG; Aa%--relation percentage expressed between a wave amplitude and total amplitude of the ACG; pulse transmission time--since S2 to ID. Statistically significant correlations (p less than 0.05) between I (years expressed) and the previously mentioned variables were investigated. It was possible to verify: a) the IEM and FIS intervals were not significantly correlated with I; b) the FE had a linear, positive and significant correlation with I (r = 0.222); c) the correlations between FE and heart rate (FC) were not significantly different between the considered age groups (14-34, 35-49, 50-69 years); d) the S2O interval had a linear, negative and significant correlation with FC (r = -0.196), and a linear, positive and significant correlation with I (r = 0.392); e) multiple regression equation between S2O, I and FC was: S2O = 70 - 0.36 x FC + 0.55 x I; f) the Aa% had

  13. Relationship between cutoff frequency and accuracy in time-interval photon statistics applied to oscillating signals

    NASA Astrophysics Data System (ADS)

    Rebolledo, M. A.; Martinez-Betorz, J. A.

    1989-04-01

    In this paper the accuracy in the determination of the period of an oscillating signal, when obtained from the photon statistics time-interval probability, is studied as a function of the precision (the inverse of the cutoff frequency of the photon counting system) with which time intervals are measured. The results are obtained by means of an experiment with a square-wave signal, where the Fourier or square-wave transforms of the time-interval probability are measured. It is found that for values of the frequency of the signal near the cutoff frequency the errors in the period are small.

  14. System implications of the ambulance arrival-to-patient contact interval on response interval compliance.

    PubMed

    Campbell, J P; Gratton, M C; Salomone, J A; Lindholm, D J; Watson, W A

    1994-01-01

    In some emergency medical services (EMS) system designs, response time intervals are mandated with monetary penalties for noncompliance. These times are set with the goal of providing rapid, definitive patient care. The time interval of vehicle at scene-to-patient access (VSPA) has been measured, but its effect on response time interval compliance has not been determined. To determine the effect of the VSPA interval on the mandated code 1 (< 9 min) and code 2 (< 13 min) response time interval compliance in an urban, public-utility model system. A prospective, observational study used independent third-party riders to collect the VSPA interval for emergency life-threatening (code 1) and emergency nonlife-threatening (code 2) calls. The VSPA interval was added to the 9-1-1 call-to-dispatch and vehicle dispatch-to-scene intervals to determine the total time interval from call received until paramedic access to the patient (9-1-1 call-to-patient access). Compliance with the mandated response time intervals was determined using the traditional time intervals (9-1-1 call-to-scene) plus the VSPA time intervals (9-1-1 call-to-patient access). Chi-square was used to determine statistical significance. Of the 216 observed calls, 198 were matched to the traditional time intervals. Sixty-three were code 1, and 135 were code 2. Of the code 1 calls, 90.5% were compliant using 9-1-1 call-to-scene intervals dropping to 63.5% using 9-1-1 call-to-patient access intervals (p < 0.0005). Of the code 2 calls, 94.1% were compliant using 9-1-1 call-to-scene intervals. Compliance decreased to 83.7% using 9-1-1 call-to-patient access intervals (p = 0.012). The addition of the VSPA interval to the traditional time intervals impacts system response time compliance. Using 9-1-1 call-to-scene compliance as a basis for measuring system performance underestimates the time for the delivery of definitive care. This must be considered when response time interval compliances are defined.

  15. Design of time interval generator based on hybrid counting method

    NASA Astrophysics Data System (ADS)

    Yao, Yuan; Wang, Zhaoqi; Lu, Houbing; Chen, Lian; Jin, Ge

    2016-10-01

    Time Interval Generators (TIGs) are frequently used for the characterizations or timing operations of instruments in particle physics experiments. Though some "off-the-shelf" TIGs can be employed, the necessity of a custom test system or control system makes the TIGs, being implemented in a programmable device desirable. Nowadays, the feasibility of using Field Programmable Gate Arrays (FPGAs) to implement particle physics instrumentation has been validated in the design of Time-to-Digital Converters (TDCs) for precise time measurement. The FPGA-TDC technique is based on the architectures of Tapped Delay Line (TDL), whose delay cells are down to few tens of picosecond. In this case, FPGA-based TIGs with high delay step are preferable allowing the implementation of customized particle physics instrumentations and other utilities on the same FPGA device. A hybrid counting method for designing TIGs with both high resolution and wide range is presented in this paper. The combination of two different counting methods realizing an integratable TIG is described in detail. A specially designed multiplexer for tap selection is emphatically introduced. The special structure of the multiplexer is devised for minimizing the different additional delays caused by the unpredictable routings from different taps to the output. A Kintex-7 FPGA is used for the hybrid counting-based implementation of a TIG, providing a resolution up to 11 ps and an interval range up to 8 s.

  16. Automatic, time-interval traffic counts for recreation area management planning

    Treesearch

    D. L. Erickson; C. J. Liu; H. K. Cordell

    1980-01-01

    Automatic, time-interval recorders were used to count directional vehicular traffic on a multiple entry/exit road network in the Red River Gorge Geological Area, Daniel Boone National Forest. Hourly counts of entering and exiting traffic differed according to recorder location, but an aggregated distribution showed a delayed peak in exiting traffic thought to be...

  17. Efficiency of time-lapse intervals and simple baits for camera surveys of wild pigs

    USGS Publications Warehouse

    Williams, B.L.; Holtfreter, R.W.; Ditchkoff, S.S.; Grand, J.B.

    2011-01-01

    Growing concerns surrounding established and expanding populations of wild pigs (Sus scrofa) have created the need for rapid and accurate surveys of these populations. We conducted surveys of a portion of the wild pig population on Fort Benning, Georgia, to determine if a longer time-lapse interval than had been previously used in surveys of wild pigs would generate similar detection results. We concurrently examined whether use of soured corn at camera sites affected the time necessary for pigs to locate a new camera site or the time pigs remained at a site. Our results suggest that a 9-min time-lapse interval generated dependable detection results for pigs and that soured corn neither attracted pigs to a site any quicker than plain, dry, whole-kernel corn, nor held them at a site longer. Maximization of time-lapse interval should decrease data and processing loads, and use of a simple, available bait should decrease cost and effort associated with more complicated baits; combination of these concepts should increase efficiency of wild pig surveys. ?? 2011 The Wildlife Society.

  18. Time intervals in the treatment of fractured femurs as indicators of the quality of trauma systems.

    PubMed

    Matityahu, Amir; Elliott, Iain; Marmor, Meir; Caldwell, Amber; Coughlin, Richard; Gosselin, Richard A

    2014-01-01

    To investigate the use of time intervals in the treatment of fractured femurs as indicators of the quality of trauma systems. Time intervals from injury to admission, admission to surgery and surgery to discharge for patients with isolated femur fractures in four low- and middle-income countries were compared with the corresponding values from one German hospital, an Israeli hospital and the National Trauma Data Bank of the United States of America by means of Student's t-tests. The correlations between the time intervals recorded in a country and that country's expenditure on health and gross domestic product (GDP) were also evaluated using Pearson's product moment correlation coefficient. Relative to patients from high-income countries, those from low- and middle-income countries were significantly more likely to be male and to have been treated by open femoral nailing, and their intervals from injury to admission, admission to surgery and surgery to discharge were significantly longer. Strong negative correlations were detected between the interval from injury to admission and government expenditure on health, and between the interval from admission to surgery and the per capita values for total expenditure on health, government expenditure on health and GDP. Strong positive correlations were detected between the interval from surgery to discharge and general government expenditure on health. The time intervals for the treatment of femur fractures are relatively long in low- and middle-income countries, can easily be measured, and are highly correlated with accessible and quantifiable country data on health and economics.

  19. Estimation of sojourn time in chronic disease screening without data on interval cases.

    PubMed

    Chen, T H; Kuo, H S; Yen, M F; Lai, M S; Tabar, L; Duffy, S W

    2000-03-01

    Estimation of the sojourn time on the preclinical detectable period in disease screening or transition rates for the natural history of chronic disease usually rely on interval cases (diagnosed between screens). However, to ascertain such cases might be difficult in developing countries due to incomplete registration systems and difficulties in follow-up. To overcome this problem, we propose three Markov models to estimate parameters without using interval cases. A three-state Markov model, a five-state Markov model related to regional lymph node spread, and a five-state Markov model pertaining to tumor size are applied to data on breast cancer screening in female relatives of breast cancer cases in Taiwan. Results based on a three-state Markov model give mean sojourn time (MST) 1.90 (95% CI: 1.18-4.86) years for this high-risk group. Validation of these models on the basis of data on breast cancer screening in the age groups 50-59 and 60-69 years from the Swedish Two-County Trial shows the estimates from a three-state Markov model that does not use interval cases are very close to those from previous Markov models taking interval cancers into account. For the five-state Markov model, a reparameterized procedure using auxiliary information on clinically detected cancers is performed to estimate relevant parameters. A good fit of internal and external validation demonstrates the feasibility of using these models to estimate parameters that have previously required interval cancers. This method can be applied to other screening data in which there are no data on interval cases.

  20. Association of narrow angles with anterior chamber area and volume measured with anterior-segment optical coherence tomography.

    PubMed

    Wu, Ren-Yi; Nongpiur, Monisha E; He, Ming-Guang; Sakata, Lisandro M; Friedman, David S; Chan, Yiong-Huak; Lavanya, Raghavan; Wong, Tien-Yin; Aung, Tin

    2011-05-01

    To describe the measurement of anterior chamber area and anterior chamber volume by anterior-segment optical coherence tomography and to investigate the association of these parameters with the presence of narrow angles. This was a cross-sectional study of subjects aged at least 50 years without ophthalmic symptoms recruited from a community clinic. All participants underwent standardized ocular examination and anterior-segment optical coherence tomography. Customized software was used to measure anterior chamber area (cross-sectional area bounded by the corneal endothelium, anterior surface of iris, and lens within the pupil) and anterior chamber volume (calculated by rotating the anterior chamber area 360° around a vertical axis through the midpoint of the anterior chamber area). An eye was considered to have narrow angles if the posterior pigmented trabecular meshwork was not visible for at least 180° on gonioscopy with the eye in the primary position. A total of 1922 subjects were included in the final analyses, 317 (16.5%) of whom had narrow angles. Mean anterior chamber area (15.6 vs 21.1 mm(2); P < .001) and anterior chamber volume (97.6 vs 142.1 mm(3); P < .001) were smaller in eyes with narrow angles compared with those in eyes without narrow angles. After adjusting for age, sex, anterior chamber depth, axial length, and pupil size, smaller anterior chamber area (odds ratio, 53.2; 95% confidence interval, 27.1-104.5) and anterior chamber volume (odds ratio, 40.2; 95% confidence interval, 21.5-75.2) were significantly associated with the presence of narrow angles. Smaller anterior chamber area and anterior chamber volume were independently associated with narrow angles in Singaporeans, even after controlling for other known ocular risk factors.

  1. Interval Training

    MedlinePlus

    Healthy Lifestyle Fitness Interval training can help you get the most out of your workout. By Mayo Clinic Staff Are you ready to shake ... spending more time at the gym? Consider aerobic interval training. Once the domain of elite athletes, interval training ...

  2. New Estimates of Intergenerational Time Intervals for the Calculation of Age and Origins of Mutations

    PubMed Central

    Tremblay, Marc; Vézina, Hélène

    2000-01-01

    Summary Intergenerational time intervals are frequently used in human population-genetics studies concerned with the ages and origins of mutations. In most cases, mean intervals of 20 or 25 years are used, regardless of the demographic characteristics of the population under study. Although these characteristics may vary from prehistoric to historical times, we suggest that this value is probably too low, and that the ages of some mutations may have been underestimated. Analyses were performed by using the BALSAC Population Register (Quebec, Canada), from which several intergenerational comparisons can be made. Family reconstitutions were used to measure interval lengths and variations in descending lineages. Various parameters were considered, such as spouse age at marriage, parental age, and reproduction levels. Mother-child and father-child intervals were compared. Intergenerational male and female intervals were also analyzed in 100 extended ascending genealogies. Results showed that a mean value of 30 years is a better estimate of intergenerational intervals than 20 or 25 years. As marked differences between male and female interval length were observed, specific values are proposed for mtDNA, autosomal, X-chromosomal, and Y-chromosomal loci. The applicability of these results for age estimates of mutations is discussed. PMID:10677323

  3. Proceedings of the Thirteenth Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting

    NASA Technical Reports Server (NTRS)

    Wardrip, S. C.

    1982-01-01

    Proceedings of an annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting are summarized. A transparent view of the state-of-the-art, an opportunity to express needs, a view of important future trends, and a review of relevant past accomplishments were considered for PTTI managers, systems engineers, and program planner. Specific aims were: to provide PTTI users with new and useful applications, procedures, and techniques; to allow the PTTI researcher to better assess fruitful directions for research efforts.

  4. Reliability and failure modes of narrow implant systems.

    PubMed

    Hirata, Ronaldo; Bonfante, Estevam A; Anchieta, Rodolfo B; Machado, Lucas S; Freitas, Gileade; Fardin, Vinicius P; Tovar, Nick; Coelho, Paulo G

    2016-09-01

    Narrow implants are indicated in areas of limited bone width or when grafting is nonviable. However, the reduction of implant diameter may compromise their performance. This study evaluated the reliability of several narrow implant systems under fatigue, after restored with single-unit crowns. Narrow implant systems were divided (n = 18 each), as follows: Astra (ASC); BioHorizons (BSC); Straumann Roxolid (SNC), Intra-Lock (IMC), and Intra-Lock one-piece abutment (ILO). Maxillary central incisor crowns were cemented and subjected to step-stress accelerated life testing in water. Use level probability Weibull curves and reliability for a mission of 100,000 cycles at 130- and 180-N loads (90 % two-sided confidence intervals) were calculated. Scanning electron microscopy was used for fractography. Reliability for 100,000 cycles at 130 N was ∼99 % in group ASC, ∼99 % in BSC, ∼96 % in SNC, ∼99 % in IMC, and ∼100 % in ILO. At 180 N, reliability of ∼34 % resulted for the ASC group, ∼91 % for BSC, ∼53 % for SNC, ∼70 % for IMC, and ∼99 % for ILO. Abutment screw fracture was the main failure mode for all groups. Reliability was not different between systems for 100,000 cycles at the 130-N load. A significant decrease was observed at the 180-N load for ASC, SNC, and IMC, whereas it was maintained for BSC and ILO. The investigated narrow implants presented mechanical performance under fatigue that suggests their safe use as single crowns in the anterior region.

  5. [Bioequivalence and generics of index drugs with narrow therapeutic margins].

    PubMed

    Le Corre, Pascal

    2010-02-01

    The market share of generic drugs in France is quite low compared to that in other European countries. Because the scientific aspects of bioequivalence that govern the use of generics are sometimes described ambiguously in the literature, they are not always perceived clearly by health professionals. This lack of clarity may be an obstacle to their use. Two drugs are considered bioequivalent if the upper and lower limits of the 90% confidence interval (90% CI) of the generic-to-brand ratio for the area under the curve (AUC) and for the maximum plasma concentration (Cmax) are included in the [-20%, +25%] interval. This interval applies to the 90% CI of the ratios of the AUC (or Cmax) and not directly to the ratio of their values. Hence, it is wrong to consider that there is a -20% to + 25% variation in the AUC (and thus in the bioavailability) between a generic and a brand-name drug. This mistake can sometimes be seen in the medical literature, however, with incorrect extrapolations. The bioequivalence is defined for a generic in relation to a brand-name drug. Consequently, two different generics of the same proprietary drug do not automatically meet the criteria for bioequivalence. Their interchangeability can present problems, especially for drugs with a narrow therapeutic index, that is, those that have a<2-fold difference between the minimum toxic concentration and minimum effective concentration in blood. More restrictive criteria have been proposed for narrow therapeutic index drugs, but there is currently no international consensus on the subject. Determining individual bioequivalence would require modified study protocols to guaranty the interchangeability of the brand-name and generic drugs so that a patient taking one formulation could change to another that would provide the same efficacy and safety. Some antiepileptic drugs have biopharmaceutical and pharmacokinetic properties inducing high levels of intraindividual variability, which can cause problems

  6. Dynamic Parameters Variability: Time Interval Interference on Ground Reaction Force During Running.

    PubMed

    Pennone, Juliana; Mezêncio, Bruno; Amadio, Alberto C; Serrão, Júlio C

    2016-04-01

    The aim of this study was to determine the effect of the time between measures on ground reaction force running variability; 15 healthy men (age = 23.8 ± 3.7 years; weight = 72.8 ± 7.7 kg; height 174.3 ± 8.4 cm) performed two trials of running 45 minutes at 9 km/hr at intervals of seven days. The ground reaction forces were recorded every 5 minutes. The coefficients of variation of indicative parameters of the ground reaction forces for each condition were compared. The coefficients of variations of the ground reaction forces curve analyzed between intervals and sessions were 21.9% and 21.48%, respectively. There was no significant difference for the ground reaction forces parameters Fy1, tFy1, TC1, Imp50, Fy2, and tFy2 between intervals and sessions. Although the ground reaction forces variables present a natural variability, this variability in intervals and in sessions remained consistent, ensuring a high reliability in repeated measures designs. © The Author(s) 2016.

  7. Narrow-band generation in random distributed feedback fiber laser.

    PubMed

    Sugavanam, Srikanth; Tarasov, Nikita; Shu, Xuewen; Churkin, Dmitry V

    2013-07-15

    Narrow-band emission of spectral width down to ~0.05 nm line-width is achieved in the random distributed feedback fiber laser employing narrow-band fiber Bragg grating or fiber Fabry-Perot interferometer filters. The observed line-width is ~10 times less than line-width of other demonstrated up to date random distributed feedback fiber lasers. The random DFB laser with Fabry-Perot interferometer filter provides simultaneously multi-wavelength and narrow-band (within each line) generation with possibility of further wavelength tuning.

  8. Adaptation to visual or auditory time intervals modulates the perception of visual apparent motion

    PubMed Central

    Zhang, Huihui; Chen, Lihan; Zhou, Xiaolin

    2012-01-01

    It is debated whether sub-second timing is subserved by a centralized mechanism or by the intrinsic properties of task-related neural activity in specific modalities (Ivry and Schlerf, 2008). By using a temporal adaptation task, we investigated whether adapting to different time intervals conveyed through stimuli in different modalities (i.e., frames of a visual Ternus display, visual blinking discs, or auditory beeps) would affect the subsequent implicit perception of visual timing, i.e., inter-stimulus interval (ISI) between two frames in a Ternus display. The Ternus display can induce two percepts of apparent motion (AM), depending on the ISI between the two frames: “element motion” for short ISIs, in which the endmost disc is seen as moving back and forth while the middle disc at the overlapping or central position remains stationary; “group motion” for longer ISIs, in which both discs appear to move in a manner of lateral displacement as a whole. In Experiment 1, participants adapted to either the typical “element motion” (ISI = 50 ms) or the typical “group motion” (ISI = 200 ms). In Experiments 2 and 3, participants adapted to a time interval of 50 or 200 ms through observing a series of two paired blinking discs at the center of the screen (Experiment 2) or hearing a sequence of two paired beeps (with pitch 1000 Hz). In Experiment 4, participants adapted to sequences of paired beeps with either low pitches (500 Hz) or high pitches (5000 Hz). After adaptation in each trial, participants were presented with a Ternus probe in which the ISI between the two frames was equal to the transitional threshold of the two types of motions, as determined by a pretest. Results showed that adapting to the short time interval in all the situations led to more reports of “group motion” in the subsequent Ternus probes; adapting to the long time interval, however, caused no aftereffect for visual adaptation but significantly more reports of group motion for

  9. Proceedings of the 7th Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting

    NASA Technical Reports Server (NTRS)

    1975-01-01

    The Proceedings contain the papers presented at the Seventh Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting and the edited record of the discussion period following each paper. This meeting provided a forum to promote more effective, efficient, economical and skillful applications of PTTI technology to the many problem areas to which PTTI offers solutions. Specifically the purpose of the meeting is to: disseminate, coordinate, and exchange practical information associated with precise time and frequency; acquaint systems engineers, technicians and managers with precise time and frequency technology and its applications; and review present and future requirements for PTTI.

  10. Regression analysis of case K interval-censored failure time data in the presence of informative censoring.

    PubMed

    Wang, Peijie; Zhao, Hui; Sun, Jianguo

    2016-12-01

    Interval-censored failure time data occur in many fields such as demography, economics, medical research, and reliability and many inference procedures on them have been developed (Sun, 2006; Chen, Sun, and Peace, 2012). However, most of the existing approaches assume that the mechanism that yields interval censoring is independent of the failure time of interest and it is clear that this may not be true in practice (Zhang et al., 2007; Ma, Hu, and Sun, 2015). In this article, we consider regression analysis of case K interval-censored failure time data when the censoring mechanism may be related to the failure time of interest. For the problem, an estimated sieve maximum-likelihood approach is proposed for the data arising from the proportional hazards frailty model and for estimation, a two-step procedure is presented. In the addition, the asymptotic properties of the proposed estimators of regression parameters are established and an extensive simulation study suggests that the method works well. Finally, we apply the method to a set of real interval-censored data that motivated this study. © 2016, The International Biometric Society.

  11. An Efficient Interval Type-2 Fuzzy CMAC for Chaos Time-Series Prediction and Synchronization.

    PubMed

    Lee, Ching-Hung; Chang, Feng-Yu; Lin, Chih-Min

    2014-03-01

    This paper aims to propose a more efficient control algorithm for chaos time-series prediction and synchronization. A novel type-2 fuzzy cerebellar model articulation controller (T2FCMAC) is proposed. In some special cases, this T2FCMAC can be reduced to an interval type-2 fuzzy neural network, a fuzzy neural network, and a fuzzy cerebellar model articulation controller (CMAC). So, this T2FCMAC is a more generalized network with better learning ability, thus, it is used for the chaos time-series prediction and synchronization. Moreover, this T2FCMAC realizes the un-normalized interval type-2 fuzzy logic system based on the structure of the CMAC. It can provide better capabilities for handling uncertainty and more design degree of freedom than traditional type-1 fuzzy CMAC. Unlike most of the interval type-2 fuzzy system, the type-reduction of T2FCMAC is bypassed due to the property of un-normalized interval type-2 fuzzy logic system. This causes T2FCMAC to have lower computational complexity and is more practical. For chaos time-series prediction and synchronization applications, the training architectures with corresponding convergence analyses and optimal learning rates based on Lyapunov stability approach are introduced. Finally, two illustrated examples are presented to demonstrate the performance of the proposed T2FCMAC.

  12. Effects of time interval between primary melanoma excision and sentinel node biopsy on positivity rate and survival.

    PubMed

    Oude Ophuis, Charlotte M C; van Akkooi, Alexander C J; Rutkowski, Piotr; Voit, Christiane A; Stepniak, Joanna; Erler, Nicole S; Eggermont, Alexander M M; Wouters, Michel W J M; Grünhagen, Dirk J; Verhoef, Cornelis Kees

    2016-11-01

    Sentinel node biopsy (SNB) is essential for adequate melanoma staging. Most melanoma guidelines advocate to perform wide local excision and SNB as soon as possible, causing time pressure. To investigate the role of time interval between melanoma diagnosis and SNB on sentinel node (SN) positivity and survival. This is a retrospective observational study concerning a cohort of melanoma patients from four European Organization for Research and Treatment of Cancer Melanoma Group tertiary referral centres from 1997 to 2013. A total of 4124 melanoma patients underwent SNB. Patients were selected if date of diagnosis and follow-up (FU) information were available, and SNB was performed in <180 d. A total of 3546 patients were included. Multivariable logistic regression and Cox regression analyses were performed to investigate how baseline characteristics and time interval until SNB are related to positivity rate, disease-free survival (DFS) and melanoma-specific survival (MSS). Median time interval was 43 d (interquartile range [IQR] 29-60 d), and 705 (19.9%) of 3546 patients had a positive SN. Sentinel node positivity was equal for early surgery (≤43 d) versus late surgery (>43 d): 19.7% versus 20.1% (p = 0.771). Median FU was 50 months (IQR 24-84 months). Sentinel node metastasis (hazard ratio [HR] 3.17, 95% confidence interval [95% CI] 2.53-3.97), ulceration (HR 1.99, 95% CI 1.58-2.51), Breslow thickness (HR 1.06, 95% CI 1.04-1.08), and male gender (HR 1.58, 95% CI 1.26-1.98) (all p < 0.00001) were independently associated with worse MSS and DFS; time interval was not. No effect of time interval between melanoma diagnosis and SNB on 5-year survival or SN positivity rate was found for a time interval of up to 3 months. This information can be used to counsel patients and remove strict time limits from melanoma guidelines. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Is Perceptual Narrowing Too Narrow?

    ERIC Educational Resources Information Center

    Cashon, Cara H.; Denicola, Christopher A.

    2011-01-01

    There is a growing list of examples illustrating that infants are transitioning from having earlier abilities that appear more "universal," "broadly tuned," or "unconstrained" to having later abilities that appear more "specialized," "narrowly tuned," or "constrained." Perceptual narrowing, a well-known phenomenon related to face, speech, and…

  14. [Study on the acquiring data time and intervals for measuring performance of air cleaner on formaldehyde].

    PubMed

    Tang, Zhigang; Wang, Guifang; Xu, Dongqun; Han, Keqin; Li, Yunpu; Zhang, Aijun; Dong, Xiaoyan

    2004-09-01

    The measuring time and measuring intervals to evaluate different type of air cleaner performance to remove formaldehyde were provided. The natural decay measurement and formaldehyde removal measurement were conducted in 1.5 m3 and 30 m3 test chamber. The natural decay rate was determined by acquiring formaldehyde concentration data at 15 minute intervals for 2.5 hours. The measured decay rate was determined by acquiring formaldehyde concentration data at 5 minute intervals for 1.2 hours. When the wind power of air cleaner is smaller than 30 m3/h or measuring performance of no wind power air clearing product, the 1.5 m3 test chamber can be used. Both the natural decay rate and the measured decay rate are determined by acquiring formaldehyde concentration data at 8 minute intervals for 64 minutes. There were different measuring time and measuring intervals to evaluate different type of air cleaner performance to remove formaldehyde.

  15. Linear time-dependent reference intervals where there is measurement error in the time variable-a parametric approach.

    PubMed

    Gillard, Jonathan

    2015-12-01

    This article re-examines parametric methods for the calculation of time specific reference intervals where there is measurement error present in the time covariate. Previous published work has commonly been based on the standard ordinary least squares approach, weighted where appropriate. In fact, this is an incorrect method when there are measurement errors present, and in this article, we show that the use of this approach may, in certain cases, lead to referral patterns that may vary with different values of the covariate. Thus, it would not be the case that all patients are treated equally; some subjects would be more likely to be referred than others, hence violating the principle of equal treatment required by the International Federation for Clinical Chemistry. We show, by using measurement error models, that reference intervals are produced that satisfy the requirement for equal treatment for all subjects. © The Author(s) 2011.

  16. Reconditioning of Cassini Narrow-Angle Camera

    NASA Image and Video Library

    2002-07-23

    These five images of single stars, taken at different times with the narrow-angle camera on NASA Cassini spacecraft, show the effects of haze collecting on the camera optics, then successful removal of the haze by warming treatments.

  17. A new variable interval schedule with constant hazard rate and finite time range.

    PubMed

    Bugallo, Mehdi; Machado, Armando; Vasconcelos, Marco

    2018-05-27

    We propose a new variable interval (VI) schedule that achieves constant probability of reinforcement in time while using a bounded range of intervals. By sampling each trial duration from a uniform distribution ranging from 0 to 2 T seconds, and then applying a reinforcement rule that depends linearly on trial duration, the schedule alternates reinforced and unreinforced trials, each less than 2 T seconds, while preserving a constant hazard function. © 2018 Society for the Experimental Analysis of Behavior.

  18. Correlates of daily leisure-time physical activity in a community sample: Narrow personality traits and practical barriers.

    PubMed

    Gallagher, Patrick; Yancy, William S; Denissen, Jaap J A; Kühnel, Anja; Voils, Corrine I

    2013-12-01

    Previous studies examining correlates of leisure time physical activity (LTPA) have identified personality factors that are correlated with LTPA and practical factors that impede LTPA. The purpose of the present study was to test how several narrow traits predict daily reports of LTPA and to test whether traits that predict LTPA moderate the effects of practical barriers. 1192 participants completed baseline measures of personality, then reported their LTPA and several situational and environmental factors daily for 25 days. We used generalized estimating equations to measure how personality traits, practical barriers, and interactions between these factors affected (1) the odds of engaging in LTPA and (2) the duration of daily LTPA. Higher standing on Activity and Discipline and lower standing on Assertiveness predicted greater odds of engaging in LTPA and longer duration of LTPA, and higher standing on Aesthetics predicted shorter duration of LTPA. Poor weather conditions and less leisure time were associated with less LTPA, and effects of these barriers were generally greater among participants 30 and older. In participants older than 30, poor weather was associated with less LTPA among those with lower standing on Activity but was not associated with LTPA among those high in Activity. Despite Discipline's overall positive association with LTPA, less leisure time and less routineness were greater barriers for those high in Discipline. Assessing narrow personality traits could help target LTPA interventions to individual patients' needs and could help identify important new personality dynamics that affect LTPA.

  19. Narrow Escape of Interacting Diffusing Particles

    NASA Astrophysics Data System (ADS)

    Agranov, Tal; Meerson, Baruch

    2018-03-01

    The narrow escape problem deals with the calculation of the mean escape time (MET) of a Brownian particle from a bounded domain through a small hole on the domain's boundary. Here we develop a formalism which allows us to evaluate the nonescape probability of a gas of diffusing particles that may interact with each other. In some cases the nonescape probability allows us to evaluate the MET of the first particle. The formalism is based on the fluctuating hydrodynamics and the recently developed macroscopic fluctuation theory. We also uncover an unexpected connection between the narrow escape of interacting particles and thermal runaway in chemical reactors.

  20. Proceedings of the 30th Annual Precise Time and Time Interval (PTTI) Systems and Applications Meeting

    NASA Technical Reports Server (NTRS)

    Breakiron, Lee A. (Editor)

    1999-01-01

    This document is a compilation of technical papers presented at the 30th Annual Precise Time and Time Interval (PTTI) Systems and Applications Meeting held 1-3 December 1998 at the Hyatt Regency Hotel at Reston Town Center, Reston, Virginia. Papers are in the following categories: 1) Recent developments in rubidium, cesium, and hydrogen-based atomic frequency standards, and in trapped-ion and space clock technology; 2) National and international applications of PTTI technology with emphasis on GPS and GLONASS timing, atomic time scales, and telecommunications; 3) Applications of PTTI technology to evolving military navigation and communication systems; geodesy; aviation; and pulsars; and 4) Dissemination of precise time and frequency by means of GPS, geosynchronous communication satellites, computer networks, WAAS, and LORAN.

  1. Robust stability of interval bidirectional associative memory neural network with time delays.

    PubMed

    Liao, Xiaofeng; Wong, Kwok-wo

    2004-04-01

    In this paper, the conventional bidirectional associative memory (BAM) neural network with signal transmission delay is intervalized in order to study the bounded effect of deviations in network parameters and external perturbations. The resultant model is referred to as a novel interval dynamic BAM (IDBAM) model. By combining a number of different Lyapunov functionals with the Razumikhin technique, some sufficient conditions for the existence of unique equilibrium and robust stability are derived. These results are fairly general and can be verified easily. To go further, we extend our investigation to the time-varying delay case. Some robust stability criteria for BAM with perturbations of time-varying delays are derived. Besides, our approach for the analysis allows us to consider several different types of activation functions, including piecewise linear sigmoids with bounded activations as well as the usual C1-smooth sigmoids. We believe that the results obtained have leading significance in the design and application of BAM neural networks.

  2. Chronic Treatment with Haloperidol Induces Deficits in Working Memory and Feedback Effects of Interval Timing

    ERIC Educational Resources Information Center

    Lustig, C.; Meck, W.H.

    2005-01-01

    Normal participants (n=5) having no experience with antipsychotic drugs and medicated participants (n=5) with clinical experience with chronic low doses of haloperidol (3-10mg/day for 2-4 months) in the treatment of neuroses were evaluated for the effects of inter-trial interval (ITI) feedback on a discrete-trials peak-interval timing procedure.…

  3. Timing in a Variable Interval Procedure: Evidence for a Memory Singularity

    PubMed Central

    Matell, Matthew S.; Kim, Jung S.; Hartshorne, Loryn

    2013-01-01

    Rats were trained in either a 30s peak-interval procedure, or a 15–45s variable interval peak procedure with a uniform distribution (Exp 1) or a ramping probability distribution (Exp 2). Rats in all groups showed peak shaped response functions centered around 30s, with the uniform group having an earlier and broader peak response function and rats in the ramping group having a later peak function as compared to the single duration group. The changes in these mean functions, as well as the statistics from single trial analyses, can be better captured by a model of timing in which memory is represented by a single, average, delay to reinforcement compared to one in which all durations are stored as a distribution, such as the complete memory model of Scalar Expectancy Theory or a simple associative model. PMID:24012783

  4. Echolocating Big Brown Bats, Eptesicus fuscus, Modulate Pulse Intervals to Overcome Range Ambiguity in Cluttered Surroundings

    PubMed Central

    Wheeler, Alyssa R.; Fulton, Kara A.; Gaudette, Jason E.; Simmons, Ryan A.; Matsuo, Ikuo; Simmons, James A.

    2016-01-01

    Big brown bats (Eptesicus fuscus) emit trains of brief, wideband frequency-modulated (FM) echolocation sounds and use echoes of these sounds to orient, find insects, and guide flight through vegetation. They are observed to emit sounds that alternate between short and long inter-pulse intervals (IPIs), forming sonar sound groups. The occurrence of these strobe groups has been linked to flight in cluttered acoustic environments, but how exactly bats use sonar sound groups to orient and navigate is still a mystery. Here, the production of sound groups during clutter navigation was examined. Controlled flight experiments were conducted where the proximity of the nearest obstacles was systematically decreased while the extended scene was kept constant. Four bats flew along a corridor of varying widths (100, 70, and 40 cm) bounded by rows of vertically hanging plastic chains while in-flight echolocation calls were recorded. Bats shortened their IPIs for more rapid spatial sampling and also grouped their sounds more tightly when flying in narrower corridors. Bats emitted echolocation calls with progressively shorter IPIs over the course of a flight, and began their flights by emitting shorter starting IPI calls when clutter was denser. The percentage of sound groups containing 3 or more calls increased with increasing clutter proximity. Moreover, IPI sequences having internal structure become more pronounced when corridor width narrows. A novel metric for analyzing the temporal organization of sound sequences was developed, and the results indicate that the time interval between echolocation calls depends heavily on the preceding time interval. The occurrence of specific IPI patterns were dependent upon clutter, which suggests that sonar sound grouping may be an adaptive strategy for coping with pulse-echo ambiguity in cluttered surroundings. PMID:27445723

  5. Computing Role Assignments of Proper Interval Graphs in Polynomial Time

    NASA Astrophysics Data System (ADS)

    Heggernes, Pinar; van't Hof, Pim; Paulusma, Daniël

    A homomorphism from a graph G to a graph R is locally surjective if its restriction to the neighborhood of each vertex of G is surjective. Such a homomorphism is also called an R-role assignment of G. Role assignments have applications in distributed computing, social network theory, and topological graph theory. The Role Assignment problem has as input a pair of graphs (G,R) and asks whether G has an R-role assignment. This problem is NP-complete already on input pairs (G,R) where R is a path on three vertices. So far, the only known non-trivial tractable case consists of input pairs (G,R) where G is a tree. We present a polynomial time algorithm that solves Role Assignment on all input pairs (G,R) where G is a proper interval graph. Thus we identify the first graph class other than trees on which the problem is tractable. As a complementary result, we show that the problem is Graph Isomorphism-hard on chordal graphs, a superclass of proper interval graphs and trees.

  6. Experimental study on occupant evacuation in narrow seat aisle

    NASA Astrophysics Data System (ADS)

    Huang, Shenshi; Lu, Shouxiang; Lo, Siuming; Li, Changhai; Guo, Yafei

    2018-07-01

    Narrow seat aisle is an important area in the train car interior due to the large passenger population, however evacuation therein has not gained enough concerns. In this experimental study, the occupant evacuation of the narrow seat aisle area is investigated, with the aisle width of 0.4-0.6 m and the evacuation direction of forward and backward. The evacuation behaviors are analyzed based on the video record, and the discussion is carried out in the aspect of evacuation time, crowdedness, evacuation order, and aisle conflicts. The result shows that with the increasing aisle width, total evacuation time and the average specific evacuation rate decrease. The aisle is crowded for some time, with a large linear occupant densities. The evacuation order of each occupant is mainly related to the seat position. Moreover, it is found that the aisle conflicts can be well described by Burstedde's model. This study gives a useful benchmark for evacuation simulation of narrow seat aisle, and provides reference to safety design of seat area in train cars.

  7. Normal reference intervals and the effects of time and feeding on serum bile acid concentrations in llamas.

    PubMed

    Andreasen, C B; Pearson, E G; Smith, B B; Gerros, T C; Lassen, E D

    1998-04-01

    Fifty clinically healthy llamas, 0.5-13 years of age (22 intact males, 10 neutered males, 18 females), with no biochemical evidence of liver disease or hematologic abnormalities, were selected to establish serum bile acid reference intervals. Serum samples submitted to the clinical pathology laboratory were analyzed using a colorimetric enzymatic assay to establish bile acid reference intervals. A nonparametric distribution of llama bile acid concentrations was 1-23 micromol/liter for llamas >1 year of age and 10-44 micromol/liter for llamas < or = 1 year of age. A significant difference was found between these 2 age groups. No correlation was detected between gender and bile acid concentrations. The reference intervals were 1.1-22.9 micromol/liter for llamas >1 year of age and 1.8-49.8 micromol/liter for llamas < or = 1 year of age. Additionally, a separate group of 10 healthy adult llamas (5 males, 5 females, 5-11 years of age) without biochemical or hematologic abnormalities was selected to assess the effects of feeding and time intervals on serum bile acid concentrations. These 10 llamas were provided fresh water and hay ad libitum, and serum samples were obtained via an indwelling jugular catheter hourly for 11 hours. Llamas were then kept from food overnight (12 hours), and subsequent samples were taken prior to feeding (fasting baseline time, 23 hours after trial initiation) and postprandially at 0.5, 1, 2, 4, and 8 hours. In feeding trials, there was no consistent interaction between bile acid concentrations and time, feeding, or 12-hour fasting. Prior feeding or time of day did not result in serum bile acid concentrations outside the reference interval, but concentrations from individual llamas varied within this interval over time.

  8. The interval between prothrombin time tests and the quality of oral anticoagulants treatment in patients with chronic atrial fibrillation.

    PubMed

    Shalev, Varda; Rogowski, Ori; Shimron, Orit; Sheinberg, Bracha; Shapira, Itzhak; Seligsohn, Uri; Berliner, Shlomo; Misgav, Mudi

    2007-01-01

    The incidence of stroke in patients with atrial fibrillation (AF) can be significantly reduced with warfarin therapy especially if optimally controlled. To evaluate the effect of the interval between consecutive prothrombin time measurements on the time in therapeutic range (INR 2-3) in a cohort of patients with AF on chronic warfarin treatment in the community. All INR measurements available from a relatively large cohort of patients with chronic AF were reviewed and the mean interval between consecutive INR tests of each patient was correlated with the time in therapeutic range (TTR). Altogether 251,916 INR measurements performed in 4408 patients over a period of seven years were reviewed. Sixty percent of patients had their INR measured on average every 2 to 3 weeks and most others were followed at intervals of 4 weeks or longer. A small proportion (3.6%) had their INR measured on average every week. A significant decline in the time in therapeutic range was observed as the intervals between tests increased. At one to three weeks interval the TTR was 48%, at 4 weeks interval 45% and at 5 weeks 41% (P<0.0005). A five percent increment in TTR was observed if more tests were performed at multiplications of exactly 7 days (43% vs 48% P<0.0001). A better control with an increase in the TTR was observed in patients with atrial fibrillation if prothrombin time tests are performed at regular intervals of no longer than 3 weeks.

  9. A flexible model for multivariate interval-censored survival times with complex correlation structure.

    PubMed

    Falcaro, Milena; Pickles, Andrew

    2007-02-10

    We focus on the analysis of multivariate survival times with highly structured interdependency and subject to interval censoring. Such data are common in developmental genetics and genetic epidemiology. We propose a flexible mixed probit model that deals naturally with complex but uninformative censoring. The recorded ages of onset are treated as possibly censored ordinal outcomes with the interval censoring mechanism seen as arising from a coarsened measurement of a continuous variable observed as falling between subject-specific thresholds. This bypasses the requirement for the failure times to be observed as falling into non-overlapping intervals. The assumption of a normal age-of-onset distribution of the standard probit model is relaxed by embedding within it a multivariate Box-Cox transformation whose parameters are jointly estimated with the other parameters of the model. Complex decompositions of the underlying multivariate normal covariance matrix of the transformed ages of onset become possible. The new methodology is here applied to a multivariate study of the ages of first use of tobacco and first consumption of alcohol without parental permission in twins. The proposed model allows estimation of the genetic and environmental effects that are shared by both of these risk behaviours as well as those that are specific. 2006 John Wiley & Sons, Ltd.

  10. RISMA: A Rule-based Interval State Machine Algorithm for Alerts Generation, Performance Analysis and Monitoring Real-Time Data Processing

    NASA Astrophysics Data System (ADS)

    Laban, Shaban; El-Desouky, Aly

    2013-04-01

    The monitoring of real-time systems is a challenging and complicated process. So, there is a continuous need to improve the monitoring process through the use of new intelligent techniques and algorithms for detecting exceptions, anomalous behaviours and generating the necessary alerts during the workflow monitoring of such systems. The interval-based or period-based theorems have been discussed, analysed, and used by many researches in Artificial Intelligence (AI), philosophy, and linguistics. As explained by Allen, there are 13 relations between any two intervals. Also, there have also been many studies of interval-based temporal reasoning and logics over the past decades. Interval-based theorems can be used for monitoring real-time interval-based data processing. However, increasing the number of processed intervals makes the implementation of such theorems a complex and time consuming process as the relationships between such intervals are increasing exponentially. To overcome the previous problem, this paper presents a Rule-based Interval State Machine Algorithm (RISMA) for processing, monitoring, and analysing the behaviour of interval-based data, received from real-time sensors. The proposed intelligent algorithm uses the Interval State Machine (ISM) approach to model any number of interval-based data into well-defined states as well as inferring them. An interval-based state transition model and methodology are presented to identify the relationships between the different states of the proposed algorithm. By using such model, the unlimited number of relationships between similar large numbers of intervals can be reduced to only 18 direct relationships using the proposed well-defined states. For testing the proposed algorithm, necessary inference rules and code have been designed and applied to the continuous data received in near real-time from the stations of International Monitoring System (IMS) by the International Data Centre (IDC) of the Preparatory

  11. Precise time and time interval applications to electric power systems

    NASA Technical Reports Server (NTRS)

    Wilson, Robert E.

    1992-01-01

    There are many applications of precise time and time interval (frequency) in operating modern electric power systems. Many generators and customer loads are operated in parallel. The reliable transfer of electrical power to the consumer partly depends on measuring power system frequency consistently in many locations. The internal oscillators in the widely dispersed frequency measuring units must be syntonized. Elaborate protection and control systems guard the high voltage equipment from short and open circuits. For the highest reliability of electric service, engineers need to study all control system operations. Precise timekeeping networks aid in the analysis of power system operations by synchronizing the clocks on recording instruments. Utility engineers want to reproduce events that caused loss of service to customers. Precise timekeeping networks can synchronize protective relay test-sets. For dependable electrical service, all generators and large motors must remain close to speed synchronism. The stable response of a power system to perturbations is critical to continuity of electrical service. Research shows that measurement of the power system state vector can aid in the monitoring and control of system stability. If power system operators know that a lightning storm is approaching a critical transmission line or transformer, they can modify operating strategies. Knowledge of the location of a short circuit fault can speed the re-energizing of a transmission line. One fault location technique requires clocks synchronized to one microsecond. Current research seeks to find out if one microsecond timekeeping can aid and improve power system control and operation.

  12. Method for shaping and aiming narrow beams. [sonar mapping and target identification

    NASA Technical Reports Server (NTRS)

    Heyser, R. C. (Inventor)

    1981-01-01

    A sonar method and apparatus is discribed which utilizes a linear frequency chirp in a transmitter/receiver having a correlator to synthesize a narrow beamwidth pattern from otherwise broadbeam transducers when there is relative velocity between the transmitter/receiver and the target. The chirp is so produced in a generator in bandwidth, B, and time, T, as to produce a time bandwidth product, TB, that is increased for a narrower angle. A replica of the chirp produced in a generator is time delayed and Doppler shifted for use as a reference in the receiver for correlation of received chirps from targets. This reference is Doppler shifted to select targets preferentially, thereby to not only synthesize a narrow beam but also aim the beam in azimuth and elevation.

  13. CMOS direct time interval measurement of long-lived luminescence lifetimes.

    PubMed

    Yao, Lei; Yung, Ka Yi; Cheung, Maurice C; Chodavarapu, Vamsy P; Bright, Frank V

    2011-01-01

    We describe a Complementary Metal-Oxide Semiconductor (CMOS) Direct Time Interval Measurement (DTIM) Integrated Circuit (IC) to detect the decay (fall) time of the luminescence emission when analyte-sensitive luminophores are excited with an optical pulse. The CMOS DTIM IC includes 14 × 14 phototransistor array, transimpedance amplifier, regulated gain amplifier, fall time detector, and time-to-digital convertor. We examined the DTIM system to measure the emission lifetime of oxygen-sensitive luminophores tris(4,7-diphenyl-1, 10-phenanthroline) ruthenium(II) ([Ru(dpp)(3)](2+)) encapsulated in sol-gel derived xerogel thin-films. The DTIM system fabricated using TSMC 0.35 μm process functions to detect lifetimes from 4 μs to 14.4 μs but can be tuned to detect longer lifetimes. The system provides 8-bit digital output proportional to lifetimes and consumes 4.5 mW of power with 3.3 V DC supply. The CMOS system provides a useful platform for the development of reliable, robust, and miniaturized optical chemical sensors.

  14. Transient overexpression of striatal D2 receptors impairs operant motivation and interval timing.

    PubMed

    Drew, Michael R; Simpson, Eleanor H; Kellendonk, Christoph; Herzberg, William G; Lipatova, Olga; Fairhurst, Stephen; Kandel, Eric R; Malapani, Chara; Balsam, Peter D

    2007-07-18

    The striatum receives prominent dopaminergic innervation that is integral to appetitive learning, performance, and motivation. Signaling through the dopamine D2 receptor is critical for all of these processes. For instance, drugs with high affinity for the D2 receptor potently alter timing of operant responses and modulate motivation. Recently, in an attempt to model a genetic abnormality encountered in schizophrenia, mice were generated that reversibly overexpress D2 receptors specifically in the striatum (Kellendonk et al., 2006). These mice have impairments in working memory and behavioral flexibility, components of the cognitive symptoms of schizophrenia, that are not rescued when D2 overexpression is reversed in the adult. Here we report that overexpression of striatal D2 receptors also profoundly affects operant performance, a potential index of negative symptoms. Mice overexpressing D2 exhibited impairments in the ability to time food rewards in an operant interval timing task and reduced motivation to lever press for food reward in both the operant timing task and a progressive ratio schedule of reinforcement. The motivational deficit, but not the timing deficit, was rescued in adult mice by reversing D2 overexpression with doxycycline. These results suggest that early D2 overexpression alters the organization of interval timing circuits and confirms that striatal D2 signaling in the adult regulates motivational process. Moreover, overexpression of D2 under pathological conditions such as schizophrenia and Parkinson's disease could give rise to motivational and timing deficits.

  15. Heuristic algorithms for the minmax regret flow-shop problem with interval processing times.

    PubMed

    Ćwik, Michał; Józefczyk, Jerzy

    2018-01-01

    An uncertain version of the permutation flow-shop with unlimited buffers and the makespan as a criterion is considered. The investigated parametric uncertainty is represented by given interval-valued processing times. The maximum regret is used for the evaluation of uncertainty. Consequently, the minmax regret discrete optimization problem is solved. Due to its high complexity, two relaxations are applied to simplify the optimization procedure. First of all, a greedy procedure is used for calculating the criterion's value, as such calculation is NP-hard problem itself. Moreover, the lower bound is used instead of solving the internal deterministic flow-shop. The constructive heuristic algorithm is applied for the relaxed optimization problem. The algorithm is compared with previously elaborated other heuristic algorithms basing on the evolutionary and the middle interval approaches. The conducted computational experiments showed the advantage of the constructive heuristic algorithm with regards to both the criterion and the time of computations. The Wilcoxon paired-rank statistical test confirmed this conclusion.

  16. Online evolution reconstruction from a single measurement record with random time intervals for quantum communication

    NASA Astrophysics Data System (ADS)

    Zhou, Hua; Su, Yang; Wang, Rong; Zhu, Yong; Shen, Huiping; Pu, Tao; Wu, Chuanxin; Zhao, Jiyong; Zhang, Baofu; Xu, Zhiyong

    2017-10-01

    Online reconstruction of a time-variant quantum state from the encoding/decoding results of quantum communication is addressed by developing a method of evolution reconstruction from a single measurement record with random time intervals. A time-variant two-dimensional state is reconstructed on the basis of recovering its expectation value functions of three nonorthogonal projectors from a random single measurement record, which is composed from the discarded qubits of the six-state protocol. The simulated results prove that our method is robust to typical metro quantum channels. Our work extends the Fourier-based method of evolution reconstruction from the version for a regular single measurement record with equal time intervals to a unified one, which can be applied to arbitrary single measurement records. The proposed protocol of evolution reconstruction runs concurrently with the one of quantum communication, which can facilitate the online quantum tomography.

  17. A review of statistical issues with progression-free survival as an interval-censored time-to-event endpoint.

    PubMed

    Sun, Xing; Li, Xiaoyun; Chen, Cong; Song, Yang

    2013-01-01

    Frequent rise of interval-censored time-to-event data in randomized clinical trials (e.g., progression-free survival [PFS] in oncology) challenges statistical researchers in the pharmaceutical industry in various ways. These challenges exist in both trial design and data analysis. Conventional statistical methods treating intervals as fixed points, which are generally practiced by pharmaceutical industry, sometimes yield inferior or even flawed analysis results in extreme cases for interval-censored data. In this article, we examine the limitation of these standard methods under typical clinical trial settings and further review and compare several existing nonparametric likelihood-based methods for interval-censored data, methods that are more sophisticated but robust. Trial design issues involved with interval-censored data comprise another topic to be explored in this article. Unlike right-censored survival data, expected sample size or power for a trial with interval-censored data relies heavily on the parametric distribution of the baseline survival function as well as the frequency of assessments. There can be substantial power loss in trials with interval-censored data if the assessments are very infrequent. Such an additional dependency controverts many fundamental assumptions and principles in conventional survival trial designs, especially the group sequential design (e.g., the concept of information fraction). In this article, we discuss these fundamental changes and available tools to work around their impacts. Although progression-free survival is often used as a discussion point in the article, the general conclusions are equally applicable to other interval-censored time-to-event endpoints.

  18. Properties of Asymmetric Detrended Fluctuation Analysis in the time series of RR intervals

    NASA Astrophysics Data System (ADS)

    Piskorski, J.; Kosmider, M.; Mieszkowski, D.; Krauze, T.; Wykretowicz, A.; Guzik, P.

    2018-02-01

    Heart rate asymmetry is a phenomenon by which the accelerations and decelerations of heart rate behave differently, and this difference is consistent and unidirectional, i.e. in most of the analyzed recordings the inequalities have the same directions. So far, it has been established for variance and runs based types of descriptors of RR intervals time series. In this paper we apply the newly developed method of Asymmetric Detrended Fluctuation Analysis, which so far has mainly been used with economic time series, to the set of 420 stationary 30 min time series of RR intervals from young, healthy individuals aged between 20 and 40. This asymmetric approach introduces separate scaling exponents for rising and falling trends. We systematically study the presence of asymmetry in both global and local versions of this method. In this study global means "applying to the whole time series" and local means "applying to windows jumping along the recording". It is found that the correlation structure of the fluctuations left over after detrending in physiological time series shows strong asymmetric features in both magnitude, with α+ <α-, where α+ is related to heart rate decelerations and α- to heart rate accelerations, and the proportion of the signal in which the above inequality holds. A very similar effect is observed if asymmetric noise is added to a symmetric self-affine function. No such phenomena are observed in the same physiological data after shuffling or with a group of symmetric synthetic time series.

  19. Indication of multiscaling in the volatility return intervals of stock markets

    NASA Astrophysics Data System (ADS)

    Wang, Fengzhong; Yamasaki, Kazuko; Havlin, Shlomo; Stanley, H. Eugene

    2008-01-01

    The distribution of the return intervals τ between price volatilities above a threshold height q for financial records has been approximated by a scaling behavior. To explore how accurate is the scaling and therefore understand the underlined nonlinear mechanism, we investigate intraday data sets of 500 stocks which consist of Standard & Poor’s 500 index. We show that the cumulative distribution of return intervals has systematic deviations from scaling. We support this finding by studying the m -th moment μm≡⟨(τ/⟨τ⟩)m⟩1/m , which show a certain trend with the mean interval ⟨τ⟩ . We generate surrogate records using the Schreiber method, and find that their cumulative distributions almost collapse to a single curve and moments are almost constant for most ranges of ⟨τ⟩ . Those substantial differences suggest that nonlinear correlations in the original volatility sequence account for the deviations from a single scaling law. We also find that the original and surrogate records exhibit slight tendencies for short and long ⟨τ⟩ , due to the discreteness and finite size effects of the records, respectively. To avoid as possible those effects for testing the multiscaling behavior, we investigate the moments in the range 10<⟨τ⟩≤100 , and find that the exponent α from the power law fitting μm˜⟨τ⟩α has a narrow distribution around α≠0 which depends on m for the 500 stocks. The distribution of α for the surrogate records are very narrow and centered around α=0 . This suggests that the return interval distribution exhibits multiscaling behavior due to the nonlinear correlations in the original volatility.

  20. Quantifying the impact of time-varying baseline risk adjustment in the self-controlled risk interval design.

    PubMed

    Li, Lingling; Kulldorff, Martin; Russek-Cohen, Estelle; Kawai, Alison Tse; Hua, Wei

    2015-12-01

    The self-controlled risk interval design is commonly used to assess the association between an acute exposure and an adverse event of interest, implicitly adjusting for fixed, non-time-varying covariates. Explicit adjustment needs to be made for time-varying covariates, for example, age in young children. It can be performed via either a fixed or random adjustment. The random-adjustment approach can provide valid point and interval estimates but requires access to individual-level data for an unexposed baseline sample. The fixed-adjustment approach does not have this requirement and will provide a valid point estimate but may underestimate the variance. We conducted a comprehensive simulation study to evaluate their performance. We designed the simulation study using empirical data from the Food and Drug Administration-sponsored Mini-Sentinel Post-licensure Rapid Immunization Safety Monitoring Rotavirus Vaccines and Intussusception study in children 5-36.9 weeks of age. The time-varying confounder is age. We considered a variety of design parameters including sample size, relative risk, time-varying baseline risks, and risk interval length. The random-adjustment approach has very good performance in almost all considered settings. The fixed-adjustment approach can be used as a good alternative when the number of events used to estimate the time-varying baseline risks is at least the number of events used to estimate the relative risk, which is almost always the case. We successfully identified settings in which the fixed-adjustment approach can be used as a good alternative and provided guidelines on the selection and implementation of appropriate analyses for the self-controlled risk interval design. Copyright © 2015 John Wiley & Sons, Ltd.

  1. Confidence intervals for distinguishing ordinal and disordinal interactions in multiple regression.

    PubMed

    Lee, Sunbok; Lei, Man-Kit; Brody, Gene H

    2015-06-01

    Distinguishing between ordinal and disordinal interaction in multiple regression is useful in testing many interesting theoretical hypotheses. Because the distinction is made based on the location of a crossover point of 2 simple regression lines, confidence intervals of the crossover point can be used to distinguish ordinal and disordinal interactions. This study examined 2 factors that need to be considered in constructing confidence intervals of the crossover point: (a) the assumption about the sampling distribution of the crossover point, and (b) the possibility of abnormally wide confidence intervals for the crossover point. A Monte Carlo simulation study was conducted to compare 6 different methods for constructing confidence intervals of the crossover point in terms of the coverage rate, the proportion of true values that fall to the left or right of the confidence intervals, and the average width of the confidence intervals. The methods include the reparameterization, delta, Fieller, basic bootstrap, percentile bootstrap, and bias-corrected accelerated bootstrap methods. The results of our Monte Carlo simulation study suggest that statistical inference using confidence intervals to distinguish ordinal and disordinal interaction requires sample sizes more than 500 to be able to provide sufficiently narrow confidence intervals to identify the location of the crossover point. (c) 2015 APA, all rights reserved).

  2. Importance of the Time Interval between Bowel Preparation and Colonoscopy in Determining the Quality of Bowel Preparation for Full-Dose Polyethylene Glycol Preparation

    PubMed Central

    Kim, Tae Kyung; Kim, Hyung Wook; Kim, Su Jin; Ha, Jong Kun; Jang, Hyung Ha; Hong, Young Mi; Park, Su Bum; Choi, Cheol Woong; Kang, Dae Hwan

    2014-01-01

    Background/Aims The quality of bowel preparation (QBP) is the important factor in performing a successful colonoscopy. Several factors influencing QBP have been reported; however, some factors, such as the optimal preparation-to-colonoscopy time interval, remain controversial. This study aimed to determine the factors influencing QBP and the optimal time interval for full-dose polyethylene glycol (PEG) preparation. Methods A total of 165 patients who underwent colonoscopy from June 2012 to August 2012 were prospectively evaluated. The QBP was assessed using the Ottawa Bowel Preparation Scale (Ottawa) score according to several factors influencing the QBP were analyzed. Results Colonoscopies with a time interval of 5 to 6 hours had the best Ottawa score in all parts of the colon. Patients with time intervals of 6 hours or less had the better QBP than those with time intervals of more than 6 hours (p=0.046). In the multivariate analysis, the time interval (odds ratio, 1.897; 95% confidence interval, 1.006 to 3.577; p=0.048) was the only significant contributor to a satisfactory bowel preparation. Conclusions The optimal time was 5 to 6 hours for the full-dose PEG method, and the time interval was the only significant contributor to a satisfactory bowel preparation. PMID:25368750

  3. Single photon detection and timing in the Lunar Laser Ranging Experiment.

    NASA Technical Reports Server (NTRS)

    Poultney, S. K.

    1972-01-01

    The goals of the Lunar Laser Ranging Experiment lead to the need for the measurement of a 2.5 sec time interval to an accuracy of a nanosecond or better. The systems analysis which included practical retroreflector arrays, available laser systems, and large telescopes led to the necessity of single photon detection. Operation under all background illumination conditions required auxiliary range gates and extremely narrow spectral and spatial filters in addition to the effective gate provided by the time resolution. Nanosecond timing precision at relatively high detection efficiency was obtained using the RCA C31000F photomultiplier and Ortec 270 constant fraction of pulse-height timing discriminator. The timing accuracy over the 2.5 sec interval was obtained using a digital interval with analog vernier ends. Both precision and accuracy are currently checked internally using a triggerable, nanosecond light pulser. Future measurements using sub-nanosecond laser pulses will be limited by the time resolution of single photon detectors.

  4. Theoretical implications of quantitative properties of interval timing and probability estimation in mouse and rat.

    PubMed

    Kheifets, Aaron; Freestone, David; Gallistel, C R

    2017-07-01

    In three experiments with mice ( Mus musculus ) and rats (Rattus norvigicus), we used a switch paradigm to measure quantitative properties of the interval-timing mechanism. We found that: 1) Rodents adjusted the precision of their timed switches in response to changes in the interval between the short and long feed latencies (the temporal goalposts). 2) The variability in the timing of the switch response was reduced or unchanged in the face of large trial-to-trial random variability in the short and long feed latencies. 3) The adjustment in the distribution of switch latencies in response to changes in the relative frequency of short and long trials was sensitive to the asymmetry in the Kullback-Leibler divergence. The three results suggest that durations are represented with adjustable precision, that they are timed by multiple timers, and that there is a trial-by-trial (episodic) record of feed latencies in memory. © 2017 Society for the Experimental Analysis of Behavior.

  5. Proceedings of the 8th Precise Time and Time Interval (PTTI) Applications and Planning Meeting

    NASA Technical Reports Server (NTRS)

    1977-01-01

    The Proceedings contain the papers presented at the Eight Annual Precise Time and Tme Interval PTTI Applications and Planning Meeting. The edited record of the discussions following the papers and the panel discussions are also included. This meeting provided a forum for the exchange of information on precise time and frequency technology among members of the scientific community and persons with program applications. The 282 registered attendees came from various U.S. Government agencies, private industry, universities and a number of foreign countries were represented. In this meeting, papers were presented that emphasized: (1) definitions and international regulations of precise time sources and users, (2) the scientific foundations of Hydrogen Maser standards, the current developments in this field and the application experience, and (3) how to measure the stability performance properties of precise standards. As in the previous meetings, update and new papers were presented on system applications with past, present and future requirements identified.

  6. An Integrated Theory of Prospective Time Interval Estimation: The Role of Cognition, Attention, and Learning

    ERIC Educational Resources Information Center

    Taatgen, Niels A.; van Rijn, Hedderik; Anderson, John

    2007-01-01

    A theory of prospective time perception is introduced and incorporated as a module in an integrated theory of cognition, thereby extending existing theories and allowing predictions about attention and learning. First, a time perception module is established by fitting existing datasets (interval estimation and bisection and impact of secondary…

  7. Confidence Intervals for Error Rates Observed in Coded Communications Systems

    NASA Astrophysics Data System (ADS)

    Hamkins, J.

    2015-05-01

    We present methods to compute confidence intervals for the codeword error rate (CWER) and bit error rate (BER) of a coded communications link. We review several methods to compute exact and approximate confidence intervals for the CWER, and specifically consider the situation in which the true CWER is so low that only a handful, if any, codeword errors are able to be simulated. In doing so, we answer the question of how long an error-free simulation must be run in order to certify that a given CWER requirement is met with a given level of confidence, and discuss the bias introduced by aborting a simulation after observing the first codeword error. Next, we turn to the lesser studied problem of determining confidence intervals for the BER of coded systems. Since bit errors in systems that use coding or higher-order modulation do not occur independently, blind application of a method that assumes independence leads to inappropriately narrow confidence intervals. We present a new method to compute the confidence interval properly, using the first and second sample moments of the number of bit errors per codeword. This is the first method we know of to compute a confidence interval for the BER of a coded or higher-order modulation system.

  8. Interval stability for complex systems

    NASA Astrophysics Data System (ADS)

    Klinshov, Vladimir V.; Kirillov, Sergey; Kurths, Jürgen; Nekorkin, Vladimir I.

    2018-04-01

    Stability of dynamical systems against strong perturbations is an important problem of nonlinear dynamics relevant to many applications in various areas. Here, we develop a novel concept of interval stability, referring to the behavior of the perturbed system during a finite time interval. Based on this concept, we suggest new measures of stability, namely interval basin stability (IBS) and interval stability threshold (IST). IBS characterizes the likelihood that the perturbed system returns to the stable regime (attractor) in a given time. IST provides the minimal magnitude of the perturbation capable to disrupt the stable regime for a given interval of time. The suggested measures provide important information about the system susceptibility to external perturbations which may be useful for practical applications. Moreover, from a theoretical viewpoint the interval stability measures are shown to bridge the gap between linear and asymptotic stability. We also suggest numerical algorithms for quantification of the interval stability characteristics and demonstrate their potential for several dynamical systems of various nature, such as power grids and neural networks.

  9. Effect of Variations in IRU Integration Time Interval On Accuracy of Aqua Attitude Estimation

    NASA Technical Reports Server (NTRS)

    Natanson, G. A.; Tracewell, Dave

    2003-01-01

    During Aqua launch support, attitude analysts noticed several anomalies in Onboard Computer (OBC) rates and in rates computed by the ground Attitude Determination System (ADS). These included: 1) periodic jumps in the OBC pitch rate every 2 minutes; 2) spikes in ADS pitch rate every 4 minutes; 3) close agreement between pitch rates computed by ADS and those derived from telemetered OBC quaternions (in contrast to the step-wise pattern observed for telemetered OBC rates); 4) spikes of +/- 10 milliseconds in telemetered IRU integration time every 4 minutes (despite the fact that telemetered time tags of any two sequential IRU measurements were always 1 second apart from each other). An analysis presented in the paper explains this anomalous behavior by a small average offset of about 0.5 +/- 0.05 microsec in the time interval between two sequential accumulated angle measurements. It is shown that errors in the estimated pitch angle due to neglecting the aforementioned variations in the integration time interval by the OBC is within +/- 2 arcseconds. Ground attitude solutions are found to be accurate enough to see the effect of the variations on the accuracy of the estimated pitch angle.

  10. Implementation of an evidence-based order set to impact initial antibiotic time intervals in adult febrile neutropenia.

    PubMed

    Best, Janie T; Frith, Karen; Anderson, Faye; Rapp, Carla Gene; Rioux, Lisa; Ciccarello, Christina

    2011-11-01

    To evaluate the impact of the implementation of a standardized order set on the time interval in initiation of antibiotic therapy for adult patients with cancer and febrile neutropenia. Practice change. The oncology unit of an urban hospital in the south-eastern United States. Adult patients with cancer and febrile neutropenia admitted six months prior to (n = 30) or during the three months following (n = 23) implementation of the order set. Literature regarding febrile neutropenia, use of order sets, and change process was reviewed. In addition, a retrospective and concurrent chart review was conducted for adult patients admitted with febrile neutropenia. Time intervals were analyzed using SPSS® software, version 18. Initial antibiotic times, order-set use, and length of stay. An overall reduction in time intervals for initiation of antibiotic therapy was observed for presentation (t = 2.25; degrees of freedom [df] = 37; p = 0.031) and order (t = 2.67; df = 40.17; p = 0.012) to antibiotic administration, with an order-set usage of 31% in the inpatient unit and 71% in the emergency department. Findings in the presence of low order-set usage suggest that staff education and placement of the order-set antibiotics in unit-based medication dispensing machines helped reduce time intervals for initial antibiotic therapy. The use of an evidence-based approach to nursing care is essential to achieving the best outcomes for patients with febrile neutropenia. Incorporation of current evidence into an order set to guide clinical practice and comprehensive nurse, pharmacy, and physician education are needed for the successful implementation of evidence-based practice changes.

  11. Effective data validation of high-frequency data: time-point-, time-interval-, and trend-based methods.

    PubMed

    Horn, W; Miksch, S; Egghart, G; Popow, C; Paky, F

    1997-09-01

    Real-time systems for monitoring and therapy planning, which receive their data from on-line monitoring equipment and computer-based patient records, require reliable data. Data validation has to utilize and combine a set of fast methods to detect, eliminate, and repair faulty data, which may lead to life-threatening conclusions. The strength of data validation results from the combination of numerical and knowledge-based methods applied to both continuously-assessed high-frequency data and discontinuously-assessed data. Dealing with high-frequency data, examining single measurements is not sufficient. It is essential to take into account the behavior of parameters over time. We present time-point-, time-interval-, and trend-based methods for validation and repair. These are complemented by time-independent methods for determining an overall reliability of measurements. The data validation benefits from the temporal data-abstraction process, which provides automatically derived qualitative values and patterns. The temporal abstraction is oriented on a context-sensitive and expectation-guided principle. Additional knowledge derived from domain experts forms an essential part for all of these methods. The methods are applied in the field of artificial ventilation of newborn infants. Examples from the real-time monitoring and therapy-planning system VIE-VENT illustrate the usefulness and effectiveness of the methods.

  12. Atomic Dynamics in Simple Liquid: de Gennes Narrowing Revisited

    NASA Astrophysics Data System (ADS)

    Wu, Bin; Iwashita, Takuya; Egami, Takeshi

    2018-03-01

    The de Gennes narrowing phenomenon is frequently observed by neutron or x -ray scattering measurements of the dynamics of complex systems, such as liquids, proteins, colloids, and polymers. The characteristic slowing down of dynamics in the vicinity of the maximum of the total scattering intensity is commonly attributed to enhanced cooperativity. In this Letter, we present an alternative view on its origin through the examination of the time-dependent pair correlation function, the van Hove correlation function, for a model liquid in two, three, and four dimensions. We find that the relaxation time increases monotonically with distance and the dependence on distance varies with dimension. We propose a heuristic explanation of this dependence based on a simple geometrical model. This finding sheds new light on the interpretation of the de Gennes narrowing phenomenon and the α -relaxation time.

  13. Narrow band gap amorphous silicon semiconductors

    DOEpatents

    Madan, A.; Mahan, A.H.

    1985-01-10

    Disclosed is a narrow band gap amorphous silicon semiconductor comprising an alloy of amorphous silicon and a band gap narrowing element selected from the group consisting of Sn, Ge, and Pb, with an electron donor dopant selected from the group consisting of P, As, Sb, Bi and N. The process for producing the narrow band gap amorphous silicon semiconductor comprises the steps of forming an alloy comprising amorphous silicon and at least one of the aforesaid band gap narrowing elements in amount sufficient to narrow the band gap of the silicon semiconductor alloy below that of amorphous silicon, and also utilizing sufficient amounts of the aforesaid electron donor dopant to maintain the amorphous silicon alloy as an n-type semiconductor.

  14. Time between the first and second operations for staged total knee arthroplasties when the interval is determined by the patient.

    PubMed

    Ishii, Yoshinori; Noguchi, Hideo; Takeda, Mitsuhiro; Sato, Junko; Toyabe, Shin-Ichi

    2014-01-01

    The purpose of this study was to evaluate the interval between the first and second operations for staged total knee arthroplasties (TKAs) in patients with bilateral knee osteoarthritis. Depending on satisfactory preoperative health status, the patients determined the timing of the second operation. We also analysed correlations between the interval and patient characteristics. Eighty-six patients with bilateral knee osteoarthritis were analysed. The mean follow-up time from the first TKA was 96 months. The side of the first TKA was chosen by the patients. The timing of the second TKA was determined by the patients, depending on their perceived ability to tolerate the additional pain and limitations to activities of daily living. The median interval between the first and second operations was 12.5 months, with a range of 2 to 113 months. In 43 (50%) patients, the interval was <12 months. There was no difference in the interval between females and males (p=0.861), and no correlation between the interval and body mass index or age. There was weak correlation between the year of the first TKA and the interval (R=-0.251, p=0.020), with the interval getting significantly shorter as the years progressed (p=0.032). The median interval between the first and second operations in patients who underwent staged TKAs for bilateral knee osteoarthritis was about 1 year. The results of the current study may help patients and physicians to plan effective treatment strategies for staged TKAs. Level II. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. A Narrow Quantitative Trait Locus in C. elegans Coordinately Affects Longevity, Thermotolerance, and Resistance to Paraquat

    PubMed Central

    Vertino, Anthony; Ayyadevara, Srinivas; Thaden, John J.; Reis, Robert J. Shmookler

    2011-01-01

    By linkage mapping of quantitative trait loci, we previously identified at least 11 natural genetic variants that significantly modulate Caenorhabditis elegans life-span (LS), many of which would have eluded discovery by knock-down or mutation screens. A region on chromosome IV between markers stP13 and stP35 had striking effects on longevity in three inter-strain crosses (each P < 10−9). In order to define the limits of that interval, we have now constructed two independent lines by marker-based selection during 20 backcross generations, isolating the stP13–stP35 interval from strain Bergerac-BO in a CL2a background. These congenic lines differed significantly from CL2a in LS, assayed in two environments (each P < 0.001). We then screened for exchange of flanking markers to isolate recombinants that partition this region, because fine-mapping the boundaries for overlapping heteroallelic spans can greatly narrow the implicated interval. Recombinants carrying the CL2a allele at stP35 were consistently long-lived compared to those retaining the Bergerac-BO allele (P < 0.001), and more resistant to temperature elevation and paraquat (each ∼1.7-fold, P < 0.0001), but gained little protection from ultraviolet or peroxide stresses. Two rounds of recombinant screening, followed by fine-mapping of break-points and survival testing, narrowed the interval to 0.18 Mb (13.35–13.53 Mb) containing 26 putative genes and six small-nuclear RNAs – a manageable number of targets for functional assessment. PMID:22303358

  16. Effect of insertion method and postinsertion time interval prior to force application on the removal torque of orthodontic miniscrews.

    PubMed

    Sharifi, Maryam; Ghassemi, Amirreza; Bayani, Shahin

    2015-01-01

    Success of orthodontic miniscrews in providing stable anchorage is dependent on their stability. The purpose of this study was to assess the effect of insertion method and postinsertion time interval on the removal torque of miniscrews as an indicator of their stability. Seventy-two miniscrews (Jeil Medical) were inserted into the femoral bones of three male German Shepherd dogs and assigned to nine groups of eight miniscrews. Three insertion methods, including hand-driven, motor-driven with 5.0-Ncm insertion torque, and motor-driven with 20.0-Ncm insertion torque, were tested. Three time intervals of 0, 2, and 6 weeks between miniscrew insertion and removal were tested as well. Removal torque values were measured in newton centimeters by a removal torque tester (IMADA). Data were analyzed by one-way analysis of variance (ANOVA) followed by the Bonferroni post hoc test at a .05 level of significance. A miniscrew survival rate of 93% was observed in this study. The highest mean value of removal torque among the three postinsertion intervals (2.4 ± 0.59 Ncm) was obtained immediately after miniscrew insertion with a statistically significant difference from the other two time intervals (P < .001). Insertion were observed in this regard (P = .46). The stability of miniscrews was not affected by the insertion method. However, of the postinsertion time intervals, the highest removal torque values were obtained immediately after insertion.

  17. Time interval between infective endocarditis first symptoms and diagnosis: relationship to infective endocarditis characteristics, microorganisms and prognosis.

    PubMed

    N'Guyen, Yohan; Duval, Xavier; Revest, Matthieu; Saada, Matthieu; Erpelding, Marie-Line; Selton-Suty, Christine; Bouchiat, Coralie; Delahaye, François; Chirouze, Catherine; Alla, François; Strady, Christophe; Hoen, Bruno

    2017-03-01

    To analyze the characteristics and outcome of infective endocarditis (IE) according to the time interval between IE first symptoms and diagnosis. Among the IE cases of a French population-based epidemiological survey, patients having early-diagnosed IE (diagnosis of IE within 1 month of first symptoms) were compared with those having late-diagnosed IE (diagnosis of IE more than 1 month after first symptoms). Among the 486 definite-IE, 124 (25%) had late-diagnosed IE whereas others had early-diagnosed IE. Early-diagnosed IE were independently associated with female gender (OR = 1.8; 95% CI [1.0-3.0]), prosthetic valve (OR= 2.6; 95% CI [1.4-5.0]) and staphylococci as causative pathogen (OR = 3.7; 95% CI [2.2-6.2]). Cardiac surgery theoretical indication rates were not different between early and late-diagnosed IE (56.3% vs 58.9%), whereas valve surgery performance was lower in early-diagnosed IE (41% vs 53%; p = .03). In-hospital mortality rates were higher in early-diagnosed IE than in late-diagnosed IE (25.1% vs 16.1%; p < .001). The time interval between IE first symptoms and diagnosis is closely related to the IE clinical presentation, patient characteristics and causative microorganism. Better prognosis reported in late-diagnosed IE may be related to a higher rate of valvular surgery. KEY MESSAGES Infective endocarditis, which time interval between first symptoms and diagnosis was less than one month, were mainly due to Staphylococcus aureus in France. Staphylococcus aureus infective endocarditis were associated with septic shock, transient ischemic attack or stroke and higher mortality rates than infective endocarditis due to other bacteria or infective endocarditis, which time interval between first symptoms and diagnosis was more than one month. Infective endocarditis, which time interval between first symptoms and diagnosis was more than one month, were accounting for one quarter of all infective endocarditis in our study and were

  18. A 4.2 ps Time-Interval RMS Resolution Time-to-Digital Converter Using a Bin Decimation Method in an UltraScale FPGA

    NASA Astrophysics Data System (ADS)

    Wang, Yonggang; Liu, Chong

    2016-10-01

    The common solution for a field programmable gate array (FPGA)-based time-to-digital converter (TDC) is constructing a tapped delay line (TDL) for time interpolation to yield a sub-clock time resolution. The granularity and uniformity of the delay elements of TDL determine the TDC time resolution. In this paper, we propose a dual-sampling TDL architecture and a bin decimation method that could make the delay elements as small and uniform as possible, so that the implemented TDCs can achieve a high time resolution beyond the intrinsic cell delay. Two identical full hardware-based TDCs were implemented in a Xilinx UltraScale FPGA for performance evaluation. For fixed time intervals in the range from 0 to 440 ns, the average time-interval RMS resolution is measured by the two TDCs with 4.2 ps, thus the timestamp resolution of single TDC is derived as 2.97 ps. The maximum hit rate of the TDC is as high as half the system clock rate of FPGA, namely 250 MHz in our demo prototype. Because the conventional online bin-by-bin calibration is not needed, the implementation of the proposed TDC is straightforward and relatively resource-saving.

  19. Fatigue Behavior and Modeling of Additively Manufactured Ti-6Al-4V Including Interlayer Time Interval Effects

    NASA Astrophysics Data System (ADS)

    Torries, Brian; Shamsaei, Nima

    2017-12-01

    The effects of different cooling rates, as achieved by varying the interlayer time interval, on the fatigue behavior of additively manufactured Ti-6Al-4V specimens were investigated and modeled via a microstructure-sensitive fatigue model. Comparisons are made between two sets of specimens fabricated via Laser Engineered Net Shaping (LENS™), with variance in interlayer time interval accomplished by depositing either one or two specimens per print operation. Fully reversed, strain-controlled fatigue tests were conducted, with fractography following specimen failure. A microstructure-sensitive fatigue model was calibrated to model the fatigue behavior of both sets of specimens and was found to be capable of correctly predicting the longer fatigue lives of the single-built specimens and the reduced scatter of the double-built specimens; all data points fell within the predicted upper and lower bounds of fatigue life. The time interval effects and the ability to be modeled are important to consider when producing test specimens that are smaller than the production part (i.e., property-performance relationships).

  20. Conventional and Ambulatory Blood Pressure as Predictors of Retinal Arteriolar Narrowing

    PubMed Central

    Wei, Fang-Fei; Zhang, Zhen-Yu; Thijs, Lutgarde; Yang, Wen-Yi; Jacobs, Lotte; Cauwenberghs, Nicholas; Gu, Yu-Mei; Kuznetsova, Tatiana; Allegaert, Karel; Verhamme, Peter; Li, Yan; Struijker-Boudier, Harry A.J.

    2016-01-01

    At variance with the long established paradigm that retinal arteriolar narrowing trails hypertension, several longitudinal studies, all based on conventional blood pressure (CBP) measurement, proposed that retinal arteriolar narrowing indicates heightened microvascular resistance and precedes hypertension. In 783 randomly recruited Flemish (mean age, 38.2 years; 51.3% women), we investigated to what extent CBP and daytime (10 am to 8 pm) ambulatory blood pressure (ABP) measured at baseline (1989–2008) predicted the central retinal arteriolar equivalent (CRAE) in retinal photographs obtained at follow-up (2008–2015). Systolic/diastolic hypertension thresholds were 140/90 mm Hg for CBP and 135/85 mm Hg for ABP. In multivariable-adjusted models including both baseline CBP and ABP, CRAE after 10.3 years (median) of follow-up was unrelated to CBP (P≥0.14), whereas ABP predicted CRAE narrowing (P≤0.011). Per 1-SD increment in systolic/diastolic blood pressure, the association sizes were −0.95 µm (95% confidence interval, −2.20 to 0.30)/−0.75 µm (−1.93 to 0.42) for CBP and −1.76 µm (−2.95 to −0.58)/−1.48 µm (−2.61 to −0.34) for ABP. Patients with ambulatory hypertension at baseline (17.0%) had smaller CRAE (146.5 versus 152.6 µm; P<0.001) at follow-up. CRAE was not different (P≥0.31) between true normotension (normal CBP and ABP; prevalence, 77.6%) and white-coat hypertension (elevated CBP and normal ABP, 5.4%) and between masked hypertension (normal CBP and elevated ABP, 10.2%) and hypertension (elevated CBP and ABP, 6.8%). In conclusion, the paradigm that retinal arteriolar narrowing precedes hypertension can be explained by the limitations of CBP measurement, including nonidentification of masked and white-coat hypertension. PMID:27324224

  1. Conventional and Ambulatory Blood Pressure as Predictors of Retinal Arteriolar Narrowing.

    PubMed

    Wei, Fang-Fei; Zhang, Zhen-Yu; Thijs, Lutgarde; Yang, Wen-Yi; Jacobs, Lotte; Cauwenberghs, Nicholas; Gu, Yu-Mei; Kuznetsova, Tatiana; Allegaert, Karel; Verhamme, Peter; Li, Yan; Struijker-Boudier, Harry A J; Staessen, Jan A

    2016-08-01

    At variance with the long established paradigm that retinal arteriolar narrowing trails hypertension, several longitudinal studies, all based on conventional blood pressure (CBP) measurement, proposed that retinal arteriolar narrowing indicates heightened microvascular resistance and precedes hypertension. In 783 randomly recruited Flemish (mean age, 38.2 years; 51.3% women), we investigated to what extent CBP and daytime (10 am to 8 pm) ambulatory blood pressure (ABP) measured at baseline (1989-2008) predicted the central retinal arteriolar equivalent (CRAE) in retinal photographs obtained at follow-up (2008-2015). Systolic/diastolic hypertension thresholds were 140/90 mm Hg for CBP and 135/85 mm Hg for ABP. In multivariable-adjusted models including both baseline CBP and ABP, CRAE after 10.3 years (median) of follow-up was unrelated to CBP (P≥0.14), whereas ABP predicted CRAE narrowing (P≤0.011). Per 1-SD increment in systolic/diastolic blood pressure, the association sizes were -0.95 µm (95% confidence interval, -2.20 to 0.30)/-0.75 µm (-1.93 to 0.42) for CBP and -1.76 µm (-2.95 to -0.58)/-1.48 µm (-2.61 to -0.34) for ABP. Patients with ambulatory hypertension at baseline (17.0%) had smaller CRAE (146.5 versus 152.6 µm; P<0.001) at follow-up. CRAE was not different (P≥0.31) between true normotension (normal CBP and ABP; prevalence, 77.6%) and white-coat hypertension (elevated CBP and normal ABP, 5.4%) and between masked hypertension (normal CBP and elevated ABP, 10.2%) and hypertension (elevated CBP and ABP, 6.8%). In conclusion, the paradigm that retinal arteriolar narrowing precedes hypertension can be explained by the limitations of CBP measurement, including nonidentification of masked and white-coat hypertension. © 2016 The Authors.

  2. Atomic Dynamics in Simple Liquid: de Gennes Narrowing Revisited

    DOE PAGES

    Wu, Bin; Iwashita, Takuya; Egami, Takeshi

    2018-03-27

    The de Gennes narrowing phenomenon is frequently observed by neutron or x-ray scattering measurements of the dynamics of complex systems, such as liquids, proteins, colloids, and polymers. The characteristic slowing down of dynamics in the vicinity of the maximum of the total scattering intensity is commonly attributed to enhanced cooperativity. In this Letter, we present an alternative view on its origin through the examination of the time-dependent pair correlation function, the van Hove correlation function, for a model liquid in two, three, and four dimensions. We find that the relaxation time increases monotonically with distance and the dependence on distancemore » varies with dimension. We propose a heuristic explanation of this dependence based on a simple geometrical model. Furthermore, this finding sheds new light on the interpretation of the de Gennes narrowing phenomenon and the α-relaxation time.« less

  3. Atomic Dynamics in Simple Liquid: de Gennes Narrowing Revisited

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Bin; Iwashita, Takuya; Egami, Takeshi

    The de Gennes narrowing phenomenon is frequently observed by neutron or x-ray scattering measurements of the dynamics of complex systems, such as liquids, proteins, colloids, and polymers. The characteristic slowing down of dynamics in the vicinity of the maximum of the total scattering intensity is commonly attributed to enhanced cooperativity. In this Letter, we present an alternative view on its origin through the examination of the time-dependent pair correlation function, the van Hove correlation function, for a model liquid in two, three, and four dimensions. We find that the relaxation time increases monotonically with distance and the dependence on distancemore » varies with dimension. We propose a heuristic explanation of this dependence based on a simple geometrical model. Furthermore, this finding sheds new light on the interpretation of the de Gennes narrowing phenomenon and the α-relaxation time.« less

  4. Determining diabetic retinopathy screening interval based on time from no retinopathy to laser therapy.

    PubMed

    Hughes, Daniel; Nair, Sunil; Harvey, John N

    2017-12-01

    Objectives To determine the necessary screening interval for retinopathy in diabetic patients with no retinopathy based on time to laser therapy and to assess long-term visual outcome following screening. Methods In a population-based community screening programme in North Wales, 2917 patients were followed until death or for approximately 12 years. At screening, 2493 had no retinopathy; 424 had mostly minor degrees of non-proliferative retinopathy. Data on timing of first laser therapy and visual outcome following screening were obtained from local hospitals and ophthalmology units. Results Survival analysis showed that very few of the no retinopathy at screening group required laser therapy in the early years compared with the non-proliferative retinopathy group ( p < 0.001). After two years, <0.1% of the no retinopathy at screening group required laser therapy, and at three years 0.2% (cumulative), lower rates of treatment than have been suggested by analyses of sight-threatening retinopathy determined photographically. At follow-up (mean 7.8 ± 4.6 years), mild to moderate visual impairment in one or both eyes due to diabetic retinopathy was more common in those with retinopathy at screening (26% vs. 5%, p < 0.001), but blindness due to diabetes occurred in only 1 in 1000. Conclusions Optimum screening intervals should be determined from time to active treatment. Based on requirement for laser therapy, the screening interval for diabetic patients with no retinopathy can be extended to two to three years. Patients who attend for retinal screening and treatment who have no or non-proliferative retinopathy now have a very low risk of eventual blindness from diabetes.

  5. In situ evaluation of surface roughness and micromorphology of temporary soft denture liner materials at different time intervals.

    PubMed

    Araújo, Célio U; Basting, Roberta T

    2018-03-01

    To perform an in situ evaluation of surface roughness and micromorphology of two soft liner materials for dentures at different time intervals. The surface roughness of materials may influence the adhesion of micro-organisms and inflammation of the mucosal tissues. The in situ evaluation of surface roughness and the micromorphology of soft liner materials over the course of time may present results different from those of in vitro studies, considering the constant presence of saliva and food, the changes in temperature and the pH level in the oral cavity. Forty-eight rectangular specimens of each of the two soft liner materials were fabricated: a silicone-based material (Mucopren Soft) and an acrylic resin-based material (Trusoft). The specimens were placed in the dentures of 12 participants (n = 12), and the materials were evaluated for surface roughness and micromorphology at different time intervals: 0, 7, 30 and 60 days. Roughness (Ra) was evaluated by means of a roughness tester. Surface micromorphology was evaluated by scanning electron microscopy. Analysis of variance for randomised block design and Tukey's test showed that surface roughness values were lower in the groups using the silicone-based material at all the time intervals (P < .0001). The average surface roughness was higher at time interval 0 than at the other intervals, for both materials (P < .0001). The surface micromorphology showed that the silicone material presented a more regular and smoother surface than the acrylic resin-based material. The surface roughness of acrylic resin-based and silicone-based denture soft liner materials decreased after 7 days of evaluation, leading to a smoother surface over time. The silicone-based material showed lower roughness values and a smoother surface than the acrylic resin-based material, thereby making it preferred when selecting more appropriate material, due its tendency to promote less biofilm build-up. © 2017 John Wiley & Sons A/S and The

  6. Thirty Meter Telescope narrow-field infrared adaptive optics system real-time controller prototyping results

    NASA Astrophysics Data System (ADS)

    Smith, Malcolm; Kerley, Dan; Chapin, Edward L.; Dunn, Jennifer; Herriot, Glen; Véran, Jean-Pierre; Boyer, Corinne; Ellerbroek, Brent; Gilles, Luc; Wang, Lianqi

    2016-07-01

    Prototyping and benchmarking was performed for the Real-Time Controller (RTC) of the Narrow Field InfraRed Adaptive Optics System (NFIRAOS). To perform wavefront correction, NFIRAOS utilizes two deformable mirrors (DM) and one tip/tilt stage (TTS). The RTC receives wavefront information from six Laser Guide Star (LGS) Shack- Hartmann WaveFront Sensors (WFS), one high-order Natural Guide Star Pyramid WaveFront Sensor (PWFS) and multiple low-order instrument detectors. The RTC uses this information to determine the commands to send to the wavefront correctors. NFIRAOS is the first light AO system for the Thirty Meter Telescope (TMT). The prototyping was performed using dual-socket high performance Linux servers with the real-time (PREEMPT_RT) patch and demonstrated the viability of a commercial off-the-shelf (COTS) hardware approach to large scale AO reconstruction. In particular, a large custom matrix vector multiplication (MVM) was benchmarked which met the required latency requirements. In addition all major inter-machine communication was verified to be adequate using 10Gb and 40Gb Ethernet. The results of this prototyping has enabled a CPU-based NFIRAOS RTC design to proceed with confidence and that COTS hardware can be used to meet the demanding performance requirements.

  7. Central tendency effects in time interval reproduction in autism

    PubMed Central

    Karaminis, Themelis; Cicchini, Guido Marco; Neil, Louise; Cappagli, Giulia; Aagten-Murphy, David; Burr, David; Pellicano, Elizabeth

    2016-01-01

    Central tendency, the tendency of judgements of quantities (lengths, durations etc.) to gravitate towards their mean, is one of the most robust perceptual effects. A Bayesian account has recently suggested that central tendency reflects the integration of noisy sensory estimates with prior knowledge representations of a mean stimulus, serving to improve performance. The process is flexible, so prior knowledge is weighted more heavily when sensory estimates are imprecise, requiring more integration to reduce noise. In this study we measure central tendency in autism to evaluate a recent theoretical hypothesis suggesting that autistic perception relies less on prior knowledge representations than typical perception. If true, autistic children should show reduced central tendency than theoretically predicted from their temporal resolution. We tested autistic and age- and ability-matched typical children in two child-friendly tasks: (1) a time interval reproduction task, measuring central tendency in the temporal domain; and (2) a time discrimination task, assessing temporal resolution. Central tendency reduced with age in typical development, while temporal resolution improved. Autistic children performed far worse in temporal discrimination than the matched controls. Computational simulations suggested that central tendency was much less in autistic children than predicted by theoretical modelling, given their poor temporal resolution. PMID:27349722

  8. Effect of collection-maturation interval time and pregnancy status of donor mares on oocyte developmental competence in horse cloning.

    PubMed

    Gambini, A; Andrés, G; Jarazo, J; Javier, J; Karlanian, F; Florencia, K; De Stéfano, A; Salamone, D F

    2014-02-01

    The current limitations for obtaining ovaries from slaughterhouses and the low efficiency of in vivo follicular aspiration necessitate a complete understanding of the variables that affect oocyte developmental competence in the equine. For this reason, we assessed the effect on equine oocyte meiotic competence and the subsequent in vitro cloned embryo development of 1) the time interval between ovary collection and the onset of oocyte in vitro maturation (collection-maturation interval time) and 2) the pregnancy status of the donor mares. To define the collection-maturation interval time, collected oocytes were classified according to the slaughtering time and the pregnancy status of the mare. Maturation rate was recorded and some matured oocytes of each group were used to reconstruct zona free cloned embryos. Nuclear maturation rates were lower when the collection-maturation interval time exceeded 10 h as compared to 4 h (32/83 vs. 76/136, respectively; P = 0.0128) and when the donor mare was pregnant as compared to nonpregnant (53/146 vs. 177/329, respectively; P = 0.0004). Low rates of cleaved embryos were observed when the collection-maturation interval time exceeded 10 h as compared to 6 to 10 h (11/27 vs. 33/44, respectively; P = 0.0056), but the pregnancy status of donor mares did not affect cloned equine blastocyst development (3/49 vs. 1/27 for blastocyst rates of nonpregnant and pregnant groups, respectively; P = 1.00). These results indicate that, to apply assisted reproductive technologies in horses, oocytes should be harvested within approximately 10 h after ovary collection. Also, even though ovaries from pregnant mares are a potential source of oocytes, they should be processed at the end of the collection routine due to the lower collection and maturation rate in this group.

  9. Temporal intensity interferometry for characterization of very narrow spectral lines

    NASA Astrophysics Data System (ADS)

    Tan, P. K.; Kurtsiefer, C.

    2017-08-01

    Some stellar objects exhibit very narrow spectral lines in the visible range additional to their blackbody radiation. Natural lasing has been suggested as a mechanism to explain narrow lines in Wolf-Rayet stars. However, the spectral resolution of conventional astronomical spectrographs is still about two orders of magnitude too low to test this hypothesis. We want to resolve the linewidth of narrow spectral emissions in starlight. A combination of spectral filtering with single-photon-level temporal correlation measurements breaks the resolution limit of wavelength-dispersing spectrographs by moving the linewidth measurement into the time domain. We demonstrate in a laboratory experiment that temporal intensity interferometry can determine a 20-MHz-wide linewidth of Doppler-broadened laser light and identify a coherent laser light contribution in a blackbody radiation background.

  10. Is high-intensity interval training a time-efficient exercise strategy to improve health and fitness?

    PubMed

    Gillen, Jenna B; Gibala, Martin J

    2014-03-01

    Growing research suggests that high-intensity interval training (HIIT) is a time-efficient exercise strategy to improve cardiorespiratory and metabolic health. "All out" HIIT models such as Wingate-type exercise are particularly effective, but this type of training may not be safe, tolerable or practical for many individuals. Recent studies, however, have revealed the potential for other models of HIIT, which may be more feasible but are still time-efficient, to stimulate adaptations similar to more demanding low-volume HIIT models and high-volume endurance-type training. As little as 3 HIIT sessions per week, involving ≤10 min of intense exercise within a time commitment of ≤30 min per session, including warm-up, recovery between intervals and cool down, has been shown to improve aerobic capacity, skeletal muscle oxidative capacity, exercise tolerance and markers of disease risk after only a few weeks in both healthy individuals and people with cardiometabolic disorders. Additional research is warranted, as studies conducted have been relatively short-term, with a limited number of measurements performed on small groups of subjects. However, given that "lack of time" remains one of the most commonly cited barriers to regular exercise participation, low-volume HIIT is a time-efficient exercise strategy that warrants consideration by health practitioners and fitness professionals.

  11. Simple estimation procedures for regression analysis of interval-censored failure time data under the proportional hazards model.

    PubMed

    Sun, Jianguo; Feng, Yanqin; Zhao, Hui

    2015-01-01

    Interval-censored failure time data occur in many fields including epidemiological and medical studies as well as financial and sociological studies, and many authors have investigated their analysis (Sun, The statistical analysis of interval-censored failure time data, 2006; Zhang, Stat Modeling 9:321-343, 2009). In particular, a number of procedures have been developed for regression analysis of interval-censored data arising from the proportional hazards model (Finkelstein, Biometrics 42:845-854, 1986; Huang, Ann Stat 24:540-568, 1996; Pan, Biometrics 56:199-203, 2000). For most of these procedures, however, one drawback is that they involve estimation of both regression parameters and baseline cumulative hazard function. In this paper, we propose two simple estimation approaches that do not need estimation of the baseline cumulative hazard function. The asymptotic properties of the resulting estimates are given, and an extensive simulation study is conducted and indicates that they work well for practical situations.

  12. Fluctuations in time intervals of financial data from the view point of the Gini index

    NASA Astrophysics Data System (ADS)

    Sazuka, Naoya; Inoue, Jun-ichi

    2007-09-01

    We propose an approach to explain fluctuations in time intervals of financial markets data from the view-point of the Gini index. We show the explicit form of the Gini index for a Weibull distribution: A good candidate to describe the first passage time of foreign exchange rate. The analytical expression of the Gini index compares well with the value obtained from empirical data.

  13. Poststimulation time interval-dependent effects of motor cortex anodal tDCS on reaction-time task performance.

    PubMed

    Molero-Chamizo, Andrés; Alameda Bailén, José R; Garrido Béjar, Tamara; García López, Macarena; Jaén Rodríguez, Inmaculada; Gutiérrez Lérida, Carolina; Pérez Panal, Silvia; González Ángel, Gloria; Lemus Corchero, Laura; Ruiz Vega, María J; Nitsche, Michael A; Rivera-Urbina, Guadalupe N

    2018-02-01

    Anodal transcranial direct current stimulation (tDCS) induces long-term potentiation-like plasticity, which is associated with long-lasting effects on different cognitive, emotional, and motor performances. Specifically, tDCS applied over the motor cortex is considered to improve reaction time in simple and complex tasks. The timing of tDCS relative to task performance could determine the efficacy of tDCS to modulate performance. The aim of this study was to compare the effects of a single session of anodal tDCS (1.5 mA, for 15 min) applied over the left primary motor cortex (M1) versus sham stimulation on performance of a go/no-go simple reaction-time task carried out at three different time points after tDCS-namely, 0, 30, or 60 min after stimulation. Performance zero min after anodal tDCS was improved during the whole course of the task. Performance 30 min after anodal tDCS was improved only in the last block of the reaction-time task. Performance 60 min after anodal tDCS was not significantly different throughout the entire task. These findings suggest that the motor cortex excitability changes induced by tDCS can improve motor responses, and these effects critically depend on the time interval between stimulation and task performance.

  14. An Efficient Format for Nearly Constant-Time Access to Arbitrary Time Intervals in Large Trace Files

    DOE PAGES

    Chan, Anthony; Gropp, William; Lusk, Ewing

    2008-01-01

    A powerful method to aid in understanding the performance of parallel applications uses log or trace files containing time-stamped events and states (pairs of events). These trace files can be very large, often hundreds or even thousands of megabytes. Because of the cost of accessing and displaying such files, other methods are often used that reduce the size of the tracefiles at the cost of sacrificing detail or other information. This paper describes a hierarchical trace file format that provides for display of an arbitrary time window in a time independent of the total size of the file and roughlymore » proportional to the number of events within the time window. This format eliminates the need to sacrifice data to achieve a smaller trace file size (since storage is inexpensive, it is necessary only to make efficient use of bandwidth to that storage). The format can be used to organize a trace file or to create a separate file of annotations that may be used with conventional trace files. We present an analysis of the time to access all of the events relevant to an interval of time and we describe experiments demonstrating the performance of this file format.« less

  15. An Assessment of Fixed Interval Timing in Free-Flying Honey Bees (Apis mellifera ligustica): An Analysis of Individual Performance

    PubMed Central

    Craig, David Philip Arthur; Varnon, Christopher A.; Sokolowski, Michel B. C.; Wells, Harrington; Abramson, Charles I.

    2014-01-01

    Interval timing is a key element of foraging theory, models of predator avoidance, and competitive interactions. Although interval timing is well documented in vertebrate species, it is virtually unstudied in invertebrates. In the present experiment, we used free-flying honey bees (Apis mellifera ligustica) as a model for timing behaviors. Subjects were trained to enter a hole in an automated artificial flower to receive a nectar reinforcer (i.e. reward). Responses were continuously reinforced prior to exposure to either a fixed interval (FI) 15-sec, FI 30-sec, FI 60-sec, or FI 120-sec reinforcement schedule. We measured response rate and post-reinforcement pause within each fixed interval trial between reinforcers. Honey bees responded at higher frequencies earlier in the fixed interval suggesting subject responding did not come under traditional forms of temporal control. Response rates were lower during FI conditions compared to performance on continuous reinforcement schedules, and responding was more resistant to extinction when previously reinforced on FI schedules. However, no “scalloped” or “break-and-run” patterns of group or individual responses reinforced on FI schedules were observed; no traditional evidence of temporal control was found. Finally, longer FI schedules eventually caused all subjects to cease returning to the operant chamber indicating subjects did not tolerate the longer FI schedules. PMID:24983960

  16. Distinguishing synchronous and time-varying synergies using point process interval statistics: motor primitives in frog and rat

    PubMed Central

    Hart, Corey B.; Giszter, Simon F.

    2013-01-01

    We present and apply a method that uses point process statistics to discriminate the forms of synergies in motor pattern data, prior to explicit synergy extraction. The method uses electromyogram (EMG) pulse peak timing or onset timing. Peak timing is preferable in complex patterns where pulse onsets may be overlapping. An interval statistic derived from the point processes of EMG peak timings distinguishes time-varying synergies from synchronous synergies (SS). Model data shows that the statistic is robust for most conditions. Its application to both frog hindlimb EMG and rat locomotion hindlimb EMG show data from these preparations is clearly most consistent with synchronous synergy models (p < 0.001). Additional direct tests of pulse and interval relations in frog data further bolster the support for synchronous synergy mechanisms in these data. Our method and analyses support separated control of rhythm and pattern of motor primitives, with the low level execution primitives comprising pulsed SS in both frog and rat, and both episodic and rhythmic behaviors. PMID:23675341

  17. Eliminating livelock by assigning the same priority state to each message that is input into a flushable routing system during N time intervals

    DOEpatents

    Faber, V.

    1994-11-29

    Livelock-free message routing is provided in a network of interconnected nodes that is flushable in time T. An input message processor generates sequences of at least N time intervals, each of duration T. An input register provides for receiving and holding each input message, where the message is assigned a priority state p during an nth one of the N time intervals. At each of the network nodes a message processor reads the assigned priority state and awards priority to messages with priority state (p-1) during an nth time interval and to messages with priority state p during an (n+1) th time interval. The messages that are awarded priority are output on an output path toward the addressed output message processor. Thus, no message remains in the network for a time longer than T. 4 figures.

  18. Eliminating livelock by assigning the same priority state to each message that is inputted into a flushable routing system during N time intervals

    DOEpatents

    Faber, Vance

    1994-01-01

    Livelock-free message routing is provided in a network of interconnected nodes that is flushable in time T. An input message processor generates sequences of at least N time intervals, each of duration T. An input register provides for receiving and holding each input message, where the message is assigned a priority state p during an nth one of the N time intervals. At each of the network nodes a message processor reads the assigned priority state and awards priority to messages with priority state (p-1) during an nth time interval and to messages with priority state p during an (n+1) th time interval. The messages that are awarded priority are output on an output path toward the addressed output message processor. Thus, no message remains in the network for a time longer than T.

  19. Considerations for Time Sampling Interval Durations in the Measurement of Young Children's Classroom Engagement

    ERIC Educational Resources Information Center

    Zakszeski, Brittany N.; Hojnoski, Robin L.; Wood, Brenna K.

    2017-01-01

    Classroom engagement is important to young children's academic and social development. Accurate methods of capturing this behavior are needed to inform and evaluate intervention efforts. This study compared the accuracy of interval durations (i.e., 5 s, 10 s, 15 s, 20 s, 30 s, and 60 s) of momentary time sampling (MTS) in approximating the…

  20. The time lag and interval of discharge with a spring actuated fuel injection pump

    NASA Technical Reports Server (NTRS)

    Matthews, Robertson; Gardiner, A W

    1923-01-01

    Discussed here is research on a spring activated fuel pump for solid or airless injection with small, high speed internal combustion engines. The pump characteristics under investigation were the interval of fuel injection in terms of degrees of crank travel and in absolute time, the lag between the time the injection pump plunger begins its stroke and the appearance of the jet at the orifice, and the manner in which the fuel spray builds up to a maximum when the fuel valve is opened, and then diminishes.

  1. Model for the respiratory modulation of the heart beat-to-beat time interval series

    NASA Astrophysics Data System (ADS)

    Capurro, Alberto; Diambra, Luis; Malta, C. P.

    2005-09-01

    In this study we present a model for the respiratory modulation of the heart beat-to-beat interval series. The model consists of a set of differential equations used to simulate the membrane potential of a single rabbit sinoatrial node cell, excited with a periodic input signal with added correlated noise. This signal, which simulates the input from the autonomous nervous system to the sinoatrial node, was included in the pacemaker equations as a modulation of the iNaK current pump and the potassium current iK. We focus at modeling the heart beat-to-beat time interval series from normal subjects during meditation of the Kundalini Yoga and Chi techniques. The analysis of the experimental data indicates that while the embedding of pre-meditation and control cases have a roughly circular shape, it acquires a polygonal shape during meditation, triangular for the Kundalini Yoga data and quadrangular in the case of Chi data. The model was used to assess the waveshape of the respiratory signals needed to reproduce the trajectory of the experimental data in the phase space. The embedding of the Chi data could be reproduced using a periodic signal obtained by smoothing a square wave. In the case of Kundalini Yoga data, the embedding was reproduced with a periodic signal obtained by smoothing a triangular wave having a rising branch of longer duration than the decreasing branch. Our study provides an estimation of the respiratory signal using only the heart beat-to-beat time interval series.

  2. Effects of varied doses of psilocybin on time interval reproduction in human subjects.

    PubMed

    Wackermann, Jirí; Wittmann, Marc; Hasler, Felix; Vollenweider, Franz X

    2008-04-11

    Action of a hallucinogenic substance, psilocybin, on internal time representation was investigated in two double-blind, placebo-controlled studies: Experiment 1 with 12 subjects and graded doses, and Experiment 2 with 9 subjects and a very low dose. The task consisted in repeated reproductions of time intervals in the range from 1.5 to 5s. The effects were assessed by parameter kappa of the 'dual klepsydra' model of internal time representation, fitted to individual response data and intra-individually normalized with respect to initial values. The estimates kappa were in the same order of magnitude as in earlier studies. In both experiments, kappa was significantly increased by psilocybin at 90 min from the drug intake, indicating a higher loss rate of the internal duration representation. These findings are tentatively linked to qualitative alterations of subjective time in altered states of consciousness.

  3. Summarizing the incidence of adverse events using volcano plots and time intervals.

    PubMed

    Zink, Richard C; Wolfinger, Russell D; Mann, Geoffrey

    2013-01-01

    Adverse event incidence analyses are a critical component for describing the safety profile of any new intervention. The results typically are presented in lengthy summary tables. For therapeutic areas where patients have frequent adverse events, analysis and interpretation are made more difficult by the sheer number and variety of events that occur. Understanding the risk in these instances becomes even more crucial. We describe a space-saving graphical summary that overcomes the limitations of traditional presentations of adverse events and improves interpretability of the safety profile. We present incidence analyses of adverse events graphically using volcano plots to highlight treatment differences. Data from a clinical trial of patients experiencing an aneurysmal subarachnoid hemorrhage are used for illustration. Adjustments for multiplicity are illustrated. Color is used to indicate the treatment with higher incidence; bubble size represents the total number of events that occur in the treatment arms combined. Adjustments for multiple comparisons are displayed in a manner to indicate clearly those events for which the difference between treatment arms is statistically significant. Furthermore, adverse events can be displayed by time intervals, with multiple volcano plots or animation to appreciate changes in adverse event risk over time. Such presentations can emphasize early differences across treatments that may resolve later or highlight events for which treatment differences may become more substantial with longer follow-up. Treatment arms are compared in a pairwise fashion. Volcano plots are space-saving tools that emphasize important differences between the adverse event profiles of two treatment arms. They can incorporate multiplicity adjustments in a manner that is straightforward to interpret and, by using time intervals, can illustrate how adverse event risk changes over the course of a clinical trial.

  4. Eliciting interval beliefs: An experimental study

    PubMed Central

    Peeters, Ronald; Wolk, Leonard

    2017-01-01

    In this paper we study the interval scoring rule as a mechanism to elicit subjective beliefs under varying degrees of uncertainty. In our experiment, subjects forecast the termination time of a time series to be generated from a given but unknown stochastic process. Subjects gradually learn more about the underlying process over time and hence the true distribution over termination times. We conduct two treatments, one with a high and one with a low volatility process. We find that elicited intervals are better when subjects are facing a low volatility process. In this treatment, participants learn to position their intervals almost optimally over the course of the experiment. This is in contrast with the high volatility treatment, where subjects, over the course of the experiment, learn to optimize the location of their intervals but fail to provide the optimal length. PMID:28380020

  5. Narrow field electromagnetic sensor system and method

    DOEpatents

    McEwan, Thomas E.

    1996-01-01

    A narrow field electromagnetic sensor system and method of sensing a characteristic of an object provide the capability to realize a characteristic of an object such as density, thickness, or presence, for any desired coordinate position on the object. One application is imaging. The sensor can also be used as an obstruction detector or an electronic trip wire with a narrow field without the disadvantages of impaired performance when exposed to dirt, snow, rain, or sunlight. The sensor employs a transmitter for transmitting a sequence of electromagnetic signals in response to a transmit timing signal, a receiver for sampling only the initial direct RF path of the electromagnetic signal while excluding all other electromagnetic signals in response to a receive timing signal, and a signal processor for processing the sampled direct RF path electromagnetic signal and providing an indication of the characteristic of an object. Usually, the electromagnetic signal is a short RF burst and the obstruction must provide a substantially complete eclipse of the direct RF path. By employing time-of-flight techniques, a timing circuit controls the receiver to sample only the initial direct RF path of the electromagnetic signal while not sampling indirect path electromagnetic signals. The sensor system also incorporates circuitry for ultra-wideband spread spectrum operation that reduces interference to and from other RF services while allowing co-location of multiple electronic sensors without the need for frequency assignments.

  6. Narrow field electromagnetic sensor system and method

    DOEpatents

    McEwan, T.E.

    1996-11-19

    A narrow field electromagnetic sensor system and method of sensing a characteristic of an object provide the capability to realize a characteristic of an object such as density, thickness, or presence, for any desired coordinate position on the object. One application is imaging. The sensor can also be used as an obstruction detector or an electronic trip wire with a narrow field without the disadvantages of impaired performance when exposed to dirt, snow, rain, or sunlight. The sensor employs a transmitter for transmitting a sequence of electromagnetic signals in response to a transmit timing signal, a receiver for sampling only the initial direct RF path of the electromagnetic signal while excluding all other electromagnetic signals in response to a receive timing signal, and a signal processor for processing the sampled direct RF path electromagnetic signal and providing an indication of the characteristic of an object. Usually, the electromagnetic signal is a short RF burst and the obstruction must provide a substantially complete eclipse of the direct RF path. By employing time-of-flight techniques, a timing circuit controls the receiver to sample only the initial direct RF path of the electromagnetic signal while not sampling indirect path electromagnetic signals. The sensor system also incorporates circuitry for ultra-wideband spread spectrum operation that reduces interference to and from other RF services while allowing co-location of multiple electronic sensors without the need for frequency assignments. 12 figs.

  7. Rapid water transportation through narrow one-dimensional channels by restricted hydrogen bonds.

    PubMed

    Ohba, Tomonori; Kaneko, Katsumi; Endo, Morinobu; Hata, Kenji; Kanoh, Hirofumi

    2013-01-29

    Water plays an important role in controlling chemical reactions and bioactivities. For example, water transportation through water channels in a biomembrane is a key factor in bioactivities. However, molecular-level mechanisms of water transportation are as yet unknown. Here, we investigate water transportation through narrow and wide one-dimensional (1D) channels on the basis of water-vapor adsorption rates and those determined by molecular dynamics simulations. We observed that water in narrow 1D channels was transported 3-5 times faster than that in wide 1D channels, although the narrow 1D channels provide fewer free nanospaces for water transportation. This rapid transportation is attributed to the formation of fewer hydrogen bonds between water molecules adsorbed in narrow 1D channels. The water-transportation mechanism provides the possibility of rapid communication through 1D channels and will be useful in controlling reactions and activities in water systems.

  8. Swimming performance in juvenile shortnose sturgeon (Acipenser brevirostrum): the influence of time interval and velocity increments on critical swimming tests

    PubMed Central

    Kieffer, James D.

    2017-01-01

    Abstract The most utilized method to measure swimming performance of fishes has been the critical swimming speed (UCrit) test. In this test, the fish is forced to swim against an incrementally increasing flow of water until fatigue. Before the water velocity is increased, the fish swims at the water velocity for a specific, pre-arranged time interval. The magnitude of the velocity increments and the time interval for each swimming period can vary across studies making the comparison between and within species difficult. This issue has been acknowledged in the literature, however, little empirical evidence exists that tests the importance of velocity and time increments on swimming performance in fish. A practical application for fish performance is through the design of fishways that enable fish to bypass anthropogenic structures (e.g. dams) that block migration routes, which is one of the causes of world-wide decline in sturgeon populations. While fishways will improve sturgeon conservation, they need to be specifically designed to accommodate the swimming capabilities specific for sturgeons, and it is possible that current swimming methodologies have under-estimated the swimming performance of sturgeons. The present study assessed the UCrit of shortnose sturgeon using modified UCrit to determine the importance of velocity increment (5 and 10 cm s−1) and time (5, 15 and 30 min) intervals on swimming performance. UCrit was found to be influenced by both time interval and water velocity. UCrit was generally lower in sturgeon when they were swum using 5cm s−1 compared with 10 cm s−1 increments. Velocity increment influences the UCrit more than time interval. Overall, researchers must consider the impacts of using particular swimming criteria when designing their experiments. PMID:28835841

  9. Cryogenic Detectors (Narrow Field Instruments)

    NASA Astrophysics Data System (ADS)

    Hoevers, H.; Verhoeve, P.

    Two cryogenic imaging spectrometer arrays are currently considered as focal plane instruments for XEUS. The narrow field imager 1 (NFI 1) will cover the energy range from 0.05 to 3 keV with an energy resolution of 2 eV, or better, at 500 eV. A second narrow field imager (NFI 2) covers the energy range from 1 to 15 keV with an energy resolution of 2 eV (at 1 keV) and 5 eV (at 7 keV), creating some overlap with part of the NFI 1 energy window. Both narrow field imagers have a 0.5 arcmin field of view. Their imaging capabilities are matched to the XEUS optics of 2 to 5 arcsec leading to 1 arcsec pixels. The detector arrays will be cooled by a closed cycle system comprising a mechanical cooler with a base temperature of 2.5 K and either a low temperature 3He sorption pump providing the very low temperature stage and/or an Adiabatic Demagnetization Refrigerator (ADR). The ADR cooler is explicitly needed to cool the NFI 2 array. The narrow field imager 1} Currently a 48 times 48 element array of superconducting tunnel junctions (STJ) is envisaged. Its operating temperature is in the range between 30 and 350 mK. Small, single Ta STJs (20-50 mum on a side) have shown 3.5 eV (FWHM) resolution at E = 525 eV and small arrays have been successfully demonstrated (6 times 6 pixels), or are currently tested (10 times 12 pixels). Alternatively, a prototype Distributed Read-Out Imaging Device (DROID), consisting of a linear superconducting Ta absorber of 20 times 100 mum2, including a 20 times 20 mum STJ for readout at either end, has shown a measured energy resolution of 2.4 eV (FWHM) at E = 500 eV. Simulations involving the diffusion properties as well as loss and tunnel rates have shown that the performance can be further improved by slight modifications in the geometry, and that the size of the DROIDS can be increased to 0.5-1.0 mm without loss in energy resolution. The relatively large areas and good energy resolution compared to single STJs make DROIDS good candidates for the

  10. Evaluation of the Trail Making Test and interval timing as measures of cognition in healthy adults: comparisons by age, education, and gender.

    PubMed

    Płotek, Włodzimierz; Łyskawa, Wojciech; Kluzik, Anna; Grześkowiak, Małgorzata; Podlewski, Roland; Żaba, Zbigniew; Drobnik, Leon

    2014-02-03

    Human cognitive functioning can be assessed using different methods of testing. Age, level of education, and gender may influence the results of cognitive tests. The well-known Trail Making Test (TMT), which is often used to measure the frontal lobe function, and the experimental test of Interval Timing (IT) were compared. The methods used in IT included reproduction of auditory and visual stimuli, with the subsequent production of the time intervals of 1-, 2-, 5-, and 7-seconds durations with no pattern. Subjects included 64 healthy adult volunteers aged 18-63 (33 women, 31 men). Comparisons were made based on age, education, and gender. TMT was performed quickly and was influenced by age, education, and gender. All reproduced visual and produced intervals were shortened and the reproduction of auditory stimuli was more complex. Age, education, and gender have more pronounced impact on the cognitive test than on the interval timing test. The reproduction of the short auditory stimuli was more accurate in comparison to other modalities used in the IT test. The interval timing, when compared to the TMT, offers an interesting possibility of testing. Further studies are necessary to confirm the initial observation.

  11. Pressure Fluctuation Characteristics of Narrow Gauge Train Running Through Tunnel

    NASA Astrophysics Data System (ADS)

    Suzuki, Masahiro; Sakuma, Yutaka

    Pressure fluctuations on the sides of narrow (1067 mm) gauge trains running in tunnels are measured for the first time to investigate the aerodynamic force acting on the trains. The present measurements are compared with earlier measurements obtained with the Shinkansen trains. The results are as follows: (1) The aerodynamic force, which stems from pressure fluctuations on the sides of cars, puts the energy into the vibration of the car body running through a tunnel. (2) While the pressure fluctuations appear only on one of the two sides of the trains running in double-track tunnels, the fluctuations in opposite phase on both sides in single-track tunnels. (3) The on-track test data of the narrow gauge trains show the same tendency as those of the Shinkansen trains, although it is suggested that the pressure fluctuations develop faster along the narrow gauge trains than the Shinkansen trains.

  12. High-intensity Interval Training in Different Exercise Modes: Lessons from Time to Exhaustion.

    PubMed

    Sousa, Ana Catarina; Fernandes, Ricardo J; Boas, Joao Paulo Vilas; Figueiredo, Pedro

    2018-06-20

    To provide information for high-intensity interval training (HIIT) load, we compared the temporal variables of VO 2 response at, and after, a time sustained at the exercise intensity corresponding to VO 2max (Tlim) in different exercise modes. Forty-five trained male swimmers (11), rowers (13), runners (10) and cyclists (11) completed an incremental protocol to determine the velocity (vVO 2max ) or power (wVO 2max ) at VO 2max and a square wave exercise from rest to 100% of vVO 2max /wVO 2max . The temporal variables of VO 2 response were examined using a breath-by-breath gas analyzer. VO 2 responses were not different between exercise modes, except for the percentage of VO 2max at 50% of Tlim, which was ~6% higher in rowing compared to cycling (97.70±2.90 vs 92.40±5.69%, p =0.013). During the recovery period, both swimmers and rowers evidenced higher percentages of VO 2max compared to cyclists at 30 s (65.1±10.4 and 65.7±5.6 vs 52.7±5.6%) and 60 s (41.7±10.8 and 38.4±5.4 vs 30.4±1.8%) time periods, all for p< 0.01. Furthermore, swimmers presented higher time values to reach 50% VO 2max compared to runners and cyclists (51.1±15.6 vs 38.1±6.7 and 33.8±4.7%; p <0.001). When training at 100% of VO 2max intensity, fixed intervals for HIIT could be set freely. However, recovery periods based on time or intensity are exercise-mode dependent. © Georg Thieme Verlag KG Stuttgart · New York.

  13. Variable frame rate transmission - A review of methodology and application to narrow-band LPC speech coding

    NASA Astrophysics Data System (ADS)

    Viswanathan, V. R.; Makhoul, J.; Schwartz, R. M.; Huggins, A. W. F.

    1982-04-01

    The variable frame rate (VFR) transmission methodology developed, implemented, and tested in the years 1973-1978 for efficiently transmitting linear predictive coding (LPC) vocoder parameters extracted from the input speech at a fixed frame rate is reviewed. With the VFR method, parameters are transmitted only when their values have changed sufficiently over the interval since their preceding transmission. Two distinct approaches to automatic implementation of the VFR method are discussed. The first bases the transmission decisions on comparisons between the parameter values of the present frame and the last transmitted frame. The second, which is based on a functional perceptual model of speech, compares the parameter values of all the frames that lie in the interval between the present frame and the last transmitted frame against a linear model of parameter variation over that interval. Also considered is the application of VFR transmission to the design of narrow-band LPC speech coders with average bit rates of 2000-2400 bts/s.

  14. Event-triggered fault detection for a class of discrete-time linear systems using interval observers.

    PubMed

    Zhang, Zhi-Hui; Yang, Guang-Hong

    2017-05-01

    This paper provides a novel event-triggered fault detection (FD) scheme for discrete-time linear systems. First, an event-triggered interval observer is proposed to generate the upper and lower residuals by taking into account the influence of the disturbances and the event error. Second, the robustness of the residual interval against the disturbances and the fault sensitivity are improved by introducing l 1 and H ∞ performances. Third, dilated linear matrix inequalities are used to decouple the Lyapunov matrices from the system matrices. The nonnegative conditions for the estimation error variables are presented with the aid of the slack matrix variables. This technique allows considering a more general Lyapunov function. Furthermore, the FD decision scheme is proposed by monitoring whether the zero value belongs to the residual interval. It is shown that the information communication burden is reduced by designing the event-triggering mechanism, while the FD performance can still be guaranteed. Finally, simulation results demonstrate the effectiveness of the proposed method. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  15. Narrow-headed garter snake (Thamnophis rufipunctatus)

    USGS Publications Warehouse

    Nowak, Erika M.

    2006-01-01

    The narrow-headed garter snake is a harmless, nonvenomous snake that is distinguished by its elongated, triangular-shaped head and the red or dark spots on its olive to tan body. Today, the narrow-headed garter snake is a species of special concern in the United States because of its decline over much of its historic range. Arizona's Oak Creek has historically contained the largest population of narrow-headed garter snakes in the United States. The U.S. Geological Survey (USGS) and the Arizona Game and Fish Department jointly funded research by USGS scientists in Oak Creek to shed light on the factors causing declining population numbers. The research resulted in better understanding of the snake's habitat needs, winter and summer range, and dietary habits. Based on the research findings, the U.S. Forest Service has developed recommendations that visitors and local residents can adopt to help slow the decline of the narrow-headed garter snake in Oak Creek.

  16. Deficits in Interval Timing Measured by the Dual-Task Paradigm among Children and Adolescents with Attention-Deficit/Hyperactivity Disorder

    ERIC Educational Resources Information Center

    Hwang, Shoou-Lian; Gau, Susan Shur-Fen; Hsu, Wen-Yau; Wu, Yu-Yu

    2010-01-01

    Background: The underlying mechanism of time perception deficit in long time intervals in attention-deficit/hyperactivity disorder (ADHD) is still unclear. This study used the time reproduction dual task to explore the role of the attentional resource in time perception deficits among children and adolescents with ADHD. Methods: Participants…

  17. Continuous-time interval model identification of blood glucose dynamics for type 1 diabetes

    NASA Astrophysics Data System (ADS)

    Kirchsteiger, Harald; Johansson, Rolf; Renard, Eric; del Re, Luigi

    2014-07-01

    While good physiological models of the glucose metabolism in type 1 diabetic patients are well known, their parameterisation is difficult. The high intra-patient variability observed is a further major obstacle. This holds for data-based models too, so that no good patient-specific models are available. Against this background, this paper proposes the use of interval models to cover the different metabolic conditions. The control-oriented models contain a carbohydrate and insulin sensitivity factor to be used for insulin bolus calculators directly. Available clinical measurements were sampled on an irregular schedule which prompts the use of continuous-time identification, also for the direct estimation of the clinically interpretable factors mentioned above. An identification method is derived and applied to real data from 28 diabetic patients. Model estimation was done on a clinical data-set, whereas validation results shown were done on an out-of-clinic, everyday life data-set. The results show that the interval model approach allows a much more regular estimation of the parameters and avoids physiologically incompatible parameter estimates.

  18. Effect of hyperoxia during the rest periods of interval training on perceptual recovery and oxygen re-saturation time.

    PubMed

    Peeling, Peter; Andersson, Ramon

    2011-01-01

    The effect of hyperoxic gas supplementation on the recovery time of oxygen saturation levels (S(a)O(2)), and its effect on perceptual recovery were assessed. Seven national-level kayak athletes completed two laboratory-based ergometer sessions of 6 × 3-min maximal aerobic intervals, with 2 min recovery between repetitions. During each recovery period, athletes either inhaled a hyperoxic gas (99.5 ± 0.2 % F(I)O(2)) or were given no external supplementation (control). Mean power output, stroke rate, heart rate, and ratings of perceived exertion were collected during each interval repetition, and the intensity was matched between trials. During each 2-min recovery period, post-exercise haemoglobin saturation levels were measured via pulse oximetry (S(p)O(2)), and the time taken for the S(p)O(2) to return to pre-exercise values was recorded. Subsequently, a rating of perceived recovery quality was collected. There were no differences in the levels of post-exercise de-saturation between the hyperoxic and control trials (P < 0.05), although the recovery time of S(p)O(2) was significantly faster in the hyperoxic trial (P < 0.05). There was no influence of oxygen supplementation on the athletes' perception of recovery quality. Hyperoxic gas supplementation during the recovery periods between high-intensity intervals substantially improves the recovery time of S(p)O(2) with no likely influence on recovery perception.

  19. Comparative evaluation of nickel discharge from brackets in artificial saliva at different time intervals.

    PubMed

    Jithesh, C; Venkataramana, V; Penumatsa, Narendravarma; Reddy, S N; Poornima, K Y; Rajasigamani, K

    2015-08-01

    To determine and compare the potential difference of nickel release from three different orthodontic brackets, in different artificial pH, in different time intervals. Twenty-seven samples of three different orthodontic brackets were selected and grouped as 1, 2, and 3. Each group was divided into three subgroups depending on the type of orthodontic brackets, salivary pH and the time interval. The Nickel release from each subgroup were analyzed by using inductively coupled plasma-Atomic Emission Spectrophotometer (Perkin Elmer, Optima 2100 DV, USA) model. Quantitative analysis of nickel was performed three times, and the mean value was used as result. ANOVA (F-test) was used to test the significant difference among the groups at 0.05 level of significance (P < 0.05). The descriptive method of statistics was used to calculate the mean, standard deviation, minimum and maximum. SPSS 18 software ((SPSS.Ltd, Quarry bay, Hong Kong, PASW-statistics 18) was used to analyze the study. The analysis shows a significant difference between three groups. The study shows that the nickel releases from the recycled stainless steel brackets have the highest at all 4.2 pH except in 120 h. The study result shows that the nickel release from the recycled stainless steel brackets is highest. Metal slot ceramic bracket release significantly less nickel. So, recycled stainless steel brackets should not be used for nickel allergic patients. Metal slot ceramic brackets are advisable.

  20. Comparative evaluation of nickel discharge from brackets in artificial saliva at different time intervals

    PubMed Central

    Jithesh, C.; Venkataramana, V.; Penumatsa, Narendravarma; Reddy, S. N.; Poornima, K. Y.; Rajasigamani, K.

    2015-01-01

    Objectives: To determine and compare the potential difference of nickel release from three different orthodontic brackets, in different artificial pH, in different time intervals. Materials and Methods: Twenty-seven samples of three different orthodontic brackets were selected and grouped as 1, 2, and 3. Each group was divided into three subgroups depending on the type of orthodontic brackets, salivary pH and the time interval. The Nickel release from each subgroup were analyzed by using inductively coupled plasma-Atomic Emission Spectrophotometer (Perkin Elmer, Optima 2100 DV, USA) model. Quantitative analysis of nickel was performed three times, and the mean value was used as result. ANOVA (F-test) was used to test the significant difference among the groups at 0.05 level of significance (P < 0.05). The descriptive method of statistics was used to calculate the mean, standard deviation, minimum and maximum. SPSS 18 software ((SPSS.Ltd, Quarry bay, Hong Kong, PASW-statistics 18) was used to analyze the study. Result: The analysis shows a significant difference between three groups. The study shows that the nickel releases from the recycled stainless steel brackets have the highest at all 4.2 pH except in 120 h. Conclusion: The study result shows that the nickel release from the recycled stainless steel brackets is highest. Metal slot ceramic bracket release significantly less nickel. So, recycled stainless steel brackets should not be used for nickel allergic patients. Metal slot ceramic brackets are advisable. PMID:26538924

  1. Transitioning to a narrow path: the impact of fear of falling in older adults.

    PubMed

    Dunlap, Pamela; Perera, Subashan; VanSwearingen, Jessie M; Wert, David; Brach, Jennifer S

    2012-01-01

    Everyday ambulation requires navigation of variable terrain, transitions from wide to narrow pathways, and avoiding obstacles. While the effect of age on the transition to a narrow path has been examined briefly, little is known about the impact of fear of falling on gait during the transition to a narrow path. The purpose was to examine the effect of age and fear of falling on gait during transition to a narrow path. In 31 young, mean age=25.3 years, and 30 older adults, mean age=79.6 years, step length, step time, step width and gait speed were examined during usual and transition to narrow pathway using an instrumented walkway. During the transition to narrow walk condition, fearful older adults compared to young had a wider step width (0.06 m vs 0.04 m) prior to the narrow path and took shorter steps (0.53 m vs 0.72 m; p<0.001). Compared to non-fearful older adults, fearful older adults walked slower and took shorter steps during narrow path walking (gait speed: 1.1m/s vs 0.82 m/s; p=0.01; step length: 0.60 m vs 0.47 m; p=0.03). In young and non-fearful older adults narrow path gait was similar to usual gait. Whereas older adults who were fearful, walked slower (0.82 m/s vs 0.91 m/s; p=0.001) and took shorter steps (0.44 m vs 0.53 m; p=0.004) during narrow path walking compared to usual walking. Changes in gait characteristics with transitioning to a narrow pathway were greater for fear of falling than for age. Copyright © 2011 Elsevier B.V. All rights reserved.

  2. Time interval between cover crop termination and planting influences corn seedling disease, plant growth, and yield

    USDA-ARS?s Scientific Manuscript database

    Experiments were established in controlled and field environment to evaluate the effect of time intervals between cereal rye cover crop termination and corn planting on corn seedling disease, corn growth, and grain yield in 2014 and 2015. Rye termination dates ranged from 25 days before planting (DB...

  3. On solving wave equations on fixed bounded intervals involving Robin boundary conditions with time-dependent coefficients

    NASA Astrophysics Data System (ADS)

    van Horssen, Wim T.; Wang, Yandong; Cao, Guohua

    2018-06-01

    In this paper, it is shown how characteristic coordinates, or equivalently how the well-known formula of d'Alembert, can be used to solve initial-boundary value problems for wave equations on fixed, bounded intervals involving Robin type of boundary conditions with time-dependent coefficients. A Robin boundary condition is a condition that specifies a linear combination of the dependent variable and its first order space-derivative on a boundary of the interval. Analytical methods, such as the method of separation of variables (SOV) or the Laplace transform method, are not applicable to those types of problems. The obtained analytical results by applying the proposed method, are in complete agreement with those obtained by using the numerical, finite difference method. For problems with time-independent coefficients in the Robin boundary condition(s), the results of the proposed method also completely agree with those as for instance obtained by the method of separation of variables, or by the finite difference method.

  4. Extended Versus Narrow-spectrum Antibiotics in the Management of Uncomplicated Appendicitis in Children: A Propensity-matched Comparative Effectiveness Study.

    PubMed

    Cameron, Danielle B; Melvin, Patrice; Graham, Dionne A; Glass, Charity C; Serres, Stephanie K; Kronman, Matthew P; Saito, Jacqueline M; Rangel, Shawn J

    2018-07-01

    The aim of this study was to compare the effectiveness of extended versus narrow spectrum antibiotics in preventing surgical site infections (SSIs) and hospital revisits in children with uncomplicated appendicitis. There is a paucity of high-quality evidence in the pediatric literature comparing the effectiveness of extended versus narrow-spectrum antibiotics in the prevention of SSIs associated with uncomplicated appendicitis. Clinical data from the ACS NSQIP-Pediatric Appendectomy Pilot Project were merged with antibiotic utilization data from the Pediatric Health Information System database for patients undergoing appendectomy for uncomplicated appendicitis at 17 hospitals from January 1, 2013 to June 30, 2015. Patients who received piperacillin/tazobactam (extended spectrum) were compared with those who received either cefoxitin or ceftriaxone with metronidazole (narrow spectrum) after propensity matching on demographic and severity characteristics. Study outcomes were 30-day SSI and hospital revisit rates. Of the 1389 patients included, 39.1% received piperacillin/tazobactam (range by hospital: 0% to 100%), and the remainder received narrow-spectrum agents. No differences in demographics or severity characteristics were found between groups following matching. In the matched analysis, the rates of SSI were similar between groups [extended spectrum: 2.4% vs narrow spectrum 1.8% (odds ratio, OR: 1.05, 95% confidence interval, 95% CI 0.34-3.26)], as was the rate of revisits [extended spectrum: 7.9% vs narrow spectrum 5.1% (OR: 1.46, 95% CI 0.75-2.87)]. Use of extended-spectrum antibiotics was not associated with lower rates of SSI or hospital revisits when compared with narrow-spectrum antibiotics in children with uncomplicated appendicitis. Our results challenge the routine use of extended-spectrum antibiotics observed at many hospitals, particularly given the increasing incidence of antibiotic-resistant organisms.

  5. Statistical Parameter Study of the Time Interval Distribution for Nonparalyzable, Paralyzable, and Hybrid Dead Time Models

    NASA Astrophysics Data System (ADS)

    Syam, Nur Syamsi; Maeng, Seongjin; Kim, Myo Gwang; Lim, Soo Yeon; Lee, Sang Hoon

    2018-05-01

    A large dead time of a Geiger Mueller (GM) detector may cause a large count loss in radiation measurements and consequently may cause distortion of the Poisson statistic of radiation events into a new distribution. The new distribution will have different statistical parameters compared to the original distribution. Therefore, the variance, skewness, and excess kurtosis in association with the observed count rate of the time interval distribution for well-known nonparalyzable, paralyzable, and nonparalyzable-paralyzable hybrid dead time models of a Geiger Mueller detector were studied using Monte Carlo simulation (GMSIM). These parameters were then compared with the statistical parameters of a perfect detector to observe the change in the distribution. The results show that the behaviors of the statistical parameters for the three dead time models were different. The values of the skewness and the excess kurtosis of the nonparalyzable model are equal or very close to those of the perfect detector, which are ≅2 for skewness, and ≅6 for excess kurtosis, while the statistical parameters in the paralyzable and hybrid model obtain minimum values that occur around the maximum observed count rates. The different trends of the three models resulting from the GMSIM simulation can be used to distinguish the dead time behavior of a GM counter; i.e. whether the GM counter can be described best by using the nonparalyzable, paralyzable, or hybrid model. In a future study, these statistical parameters need to be analyzed further to determine the possibility of using them to determine a dead time for each model, particularly for paralyzable and hybrid models.

  6. Alternative approach for management of an electrical storm in Brugada syndrome:Importance of primary ablation within a narrow time window.

    PubMed

    Talib, Ahmed Karim; Yui, Yoshiaki; Kaneshiro, Takashi; Sekiguchi, Yukio; Nogami, Akihiko; Aonuma, Kazutaka

    2016-06-01

    Placement of an implantable cardioverter-defibrillator (ICD) is the only powerful treatment modality for Brugada syndrome in patients presenting with ventricular fibrillation (VF). For those whose first presentation is an electrical storm, pharmacologic therapy is typically used to control VF followed by ICD implantation. We report an alternative approach whereby, before ICD implantation, emergency catheter ablation of the VF-triggering premature ventricular contraction (PVC) resulted in long-term VF-free survival. The results suggest that, because VF triggers appear in a narrow time window, ablation of the culprit PVCs that initiate VF before the index PVCs subside is a reasonable alternative approach.

  7. Return Intervals Approach to Financial Fluctuations

    NASA Astrophysics Data System (ADS)

    Wang, Fengzhong; Yamasaki, Kazuko; Havlin, Shlomo; Stanley, H. Eugene

    Financial fluctuations play a key role for financial markets studies. A new approach focusing on properties of return intervals can help to get better understanding of the fluctuations. A return interval is defined as the time between two successive volatilities above a given threshold. We review recent studies and analyze the 1000 most traded stocks in the US stock markets. We find that the distribution of the return intervals has a well approximated scaling over a wide range of thresholds. The scaling is also valid for various time windows from one minute up to one trading day. Moreover, these results are universal for stocks of different countries, commodities, interest rates as well as currencies. Further analysis shows some systematic deviations from a scaling law, which are due to the nonlinear correlations in the volatility sequence. We also examine the memory in return intervals for different time scales, which are related to the long-term correlations in the volatility. Furthermore, we test two popular models, FIGARCH and fractional Brownian motion (fBm). Both models can catch the memory effect but only fBm shows a good scaling in the return interval distribution.

  8. Droplet squeezing through a narrow constriction: Minimum impulse and critical velocity

    NASA Astrophysics Data System (ADS)

    Zhang, Zhifeng; Drapaca, Corina; Chen, Xiaolin; Xu, Jie

    2017-07-01

    Models of a droplet passing through narrow constrictions have wide applications in science and engineering. In this paper, we report our findings on the minimum impulse (momentum change) of pushing a droplet through a narrow circular constriction. The existence of this minimum impulse is mathematically derived and numerically verified. The minimum impulse happens at a critical velocity when the time-averaged Young-Laplace pressure balances the total minor pressure loss in the constriction. Finally, numerical simulations are conducted to verify these concepts. These results could be relevant to problems of energy optimization and studies of chemical and biomedical systems.

  9. Comment on “Based on interval type-2 adaptive fuzzy H∞ tracking controller for SISO time-delay nonlinear systems”

    NASA Astrophysics Data System (ADS)

    Pan, Yongping; Huang, Daoping

    2011-03-01

    In this comment, we point out the inappropriateness of Theorem 1 in the article [Tsung-Chih Lin, Mehdi Roopaei. Based on interval type-2 adaptive fuzzy H∞ tracking controller for SISO time-delay nonlinear systems. Commun Nonlinear Sci Numer Simulat 2010;15:4065-75]. For solving this problem, some formular mistakes are corrected and novel parameter adaptive laws of interval type-2 fuzzy neural network system are given.

  10. Reference intervals for selected serum biochemistry analytes in cheetahs Acinonyx jubatus.

    PubMed

    Hudson-Lamb, Gavin C; Schoeman, Johan P; Hooijberg, Emma H; Heinrich, Sonja K; Tordiffe, Adrian S W

    2016-02-26

    Published haematologic and serum biochemistry reference intervals are very scarce for captive cheetahs and even more for free-ranging cheetahs. The current study was performed to establish reference intervals for selected serum biochemistry analytes in cheetahs. Baseline serum biochemistry analytes were analysed from 66 healthy Namibian cheetahs. Samples were collected from 30 captive cheetahs at the AfriCat Foundation and 36 free-ranging cheetahs from central Namibia. The effects of captivity-status, age, sex and haemolysis score on the tested serum analytes were investigated. The biochemistry analytes that were measured were sodium, potassium, magnesium, chloride, urea and creatinine. The 90% confidence interval of the reference limits was obtained using the non-parametric bootstrap method. Reference intervals were preferentially determined by the non-parametric method and were as follows: sodium (128 mmol/L - 166 mmol/L), potassium (3.9 mmol/L - 5.2 mmol/L), magnesium (0.8 mmol/L - 1.2 mmol/L), chloride (97 mmol/L - 130 mmol/L), urea (8.2 mmol/L - 25.1 mmol/L) and creatinine (88 µmol/L - 288 µmol/L). Reference intervals from the current study were compared with International Species Information System values for cheetahs and found to be narrower. Moreover, age, sex and haemolysis score had no significant effect on the serum analytes in this study. Separate reference intervals for captive and free-ranging cheetahs were also determined. Captive cheetahs had higher urea values, most likely due to dietary factors. This study is the first to establish reference intervals for serum biochemistry analytes in cheetahs according to international guidelines. These results can be used for future health and disease assessments in both captive and free-ranging cheetahs.

  11. Narrow Networks on the Individual Marketplace in 2017.

    PubMed

    Polski, Daniel; Weiner, Janet; Zhang, Yuehan

    2017-09-01

    This Issue Brief describes the breadth of physician networks on the ACA marketplaces in 2017. We find that the overall rate of narrow networks is 21%, which is a decline since 2014 (31%) and 2016 (25%). Narrow networks are concentrated in plans sold on state-based marketplaces, at 42%, compared to 10% of plans on federally-facilitated marketplaces. Issuers that have traditionally offered Medicaid coverage have the highest prevalence of narrow network plans at 36%, with regional/local plans and provider-based plans close behind at 27% and 30%. We also find large differences in narrow networks by state and by plan type.

  12. Methods for estimating confidence intervals in interrupted time series analyses of health interventions.

    PubMed

    Zhang, Fang; Wagner, Anita K; Soumerai, Stephen B; Ross-Degnan, Dennis

    2009-02-01

    Interrupted time series (ITS) is a strong quasi-experimental research design, which is increasingly applied to estimate the effects of health services and policy interventions. We describe and illustrate two methods for estimating confidence intervals (CIs) around absolute and relative changes in outcomes calculated from segmented regression parameter estimates. We used multivariate delta and bootstrapping methods (BMs) to construct CIs around relative changes in level and trend, and around absolute changes in outcome based on segmented linear regression analyses of time series data corrected for autocorrelated errors. Using previously published time series data, we estimated CIs around the effect of prescription alerts for interacting medications with warfarin on the rate of prescriptions per 10,000 warfarin users per month. Both the multivariate delta method (MDM) and the BM produced similar results. BM is preferred for calculating CIs of relative changes in outcomes of time series studies, because it does not require large sample sizes when parameter estimates are obtained correctly from the model. Caution is needed when sample size is small.

  13. The Tacoma Narrows Bridge Collapse on Film and Video

    ERIC Educational Resources Information Center

    Olson, Don; Hook, Joseph; Doescher, Russell; Wolf, Steven

    2015-01-01

    This month marks the 75th anniversary of the Tacoma Narrows Bridge collapse. During a gale on Nov. 7, 1940, the bridge exhibited remarkable oscillations before collapsing spectacularly (Figs. 1-5). Physicists over the years have spent a great deal of time and energy studying this event. By using open-source analysis tools and digitized footage of…

  14. Collaborative derivation of reference intervals for major clinical laboratory tests in Japan.

    PubMed

    Ichihara, Kiyoshi; Yomamoto, Yoshikazu; Hotta, Taeko; Hosogaya, Shigemi; Miyachi, Hayato; Itoh, Yoshihisa; Ishibashi, Midori; Kang, Dongchon

    2016-05-01

    Three multicentre studies of reference intervals were conducted recently in Japan. The Committee on Common Reference Intervals of the Japan Society of Clinical Chemistry sought to establish common reference intervals for 40 laboratory tests which were measured in common in the three studies and regarded as well harmonized in Japan. The study protocols were comparable with recruitment mostly from hospital workers with body mass index ≤28 and no medications. Age and sex distributions were made equal to obtain a final data size of 6345 individuals. Between-subgroup differences were expressed as the SD ratio (between-subgroup SD divided by SD representing the reference interval). Between-study differences were all within acceptable levels, and thus the three datasets were merged. By adopting SD ratio ≥0.50 as a guide, sex-specific reference intervals were necessary for 12 assays. Age-specific reference intervals for females partitioned at age 45 were required for five analytes. The reference intervals derived by the parametric method resulted in appreciable narrowing of the ranges by applying the latent abnormal values exclusion method in 10 items which were closely associated with prevalent disorders among healthy individuals. Sex- and age-related profiles of reference values, derived from individuals with no abnormal results in major tests, showed peculiar patterns specific to each analyte. Common reference intervals for nationwide use were developed for 40 major tests, based on three multicentre studies by advanced statistical methods. Sex- and age-related profiles of reference values are of great relevance not only for interpreting test results, but for applying clinical decision limits specified in various clinical guidelines. © The Author(s) 2015.

  15. Emotional Modulation of Interval Timing and Time Perception

    PubMed Central

    Lake, Jessica I.; LaBar, Kevin S.; Meck, Warren H.

    2017-01-01

    Like other senses, our perception of time is not veridical, but rather, is modulated by changes in environmental context. Anecdotal experiences suggest that emotions can be powerful modulators of time perception; nevertheless, the functional and neural mechanisms underlying emotion-induced temporal distortions remain unclear. Widely accepted pacemaker-accumulator models of time perception suggest that changes in arousal and attention have unique influences on temporal judgments and contribute to emotional distortions of time perception. However, such models conflict with current views of arousal and attention suggesting that current models of time perception do not adequately explain the variability in emotion-induced temporal distortions. Instead, findings provide support for a new perspective of emotion-induced temporal distortions that emphasizes both the unique and interactive influences of arousal and attention on time perception over time. Using this framework, we discuss plausible functional and neural mechanisms of emotion-induced temporal distortions and how these temporal distortions may have important implications for our understanding of how emotions modulate our perceptual experiences in service of adaptive responding to biologically relevant stimuli. PMID:26972824

  16. Constraining the Time Interval for the Origin of Life on Earth.

    PubMed

    Pearce, Ben K D; Tupper, Andrew S; Pudritz, Ralph E; Higgs, Paul G

    2018-03-01

    Estimates of the time at which life arose on Earth make use of two types of evidence. First, astrophysical and geophysical studies provide a timescale for the formation of Earth and the Moon, for large impact events on early Earth, and for the cooling of the early magma ocean. From this evidence, we can deduce a habitability boundary, which is the earliest point at which Earth became habitable. Second, biosignatures in geological samples, including microfossils, stromatolites, and chemical isotope ratios, provide evidence for when life was actually present. From these observations we can deduce a biosignature boundary, which is the earliest point at which there is clear evidence that life existed. Studies with molecular phylogenetics and records of the changing level of oxygen in the atmosphere give additional information that helps to determine the biosignature boundary. Here, we review the data from a wide range of disciplines to summarize current information on the timings of these two boundaries. The habitability boundary could be as early as 4.5 Ga, the earliest possible estimate of the time at which Earth had a stable crust and hydrosphere, or as late as 3.9 Ga, the end of the period of heavy meteorite bombardment. The lack of consensus on whether there was a late heavy meteorite bombardment that was significant enough to prevent life is the largest uncertainty in estimating the time of the habitability boundary. The biosignature boundary is more closely constrained. Evidence from carbon isotope ratios and stromatolite fossils both point to a time close to 3.7 Ga. Life must have emerged in the interval between these two boundaries. The time taken for life to appear could, therefore, be within 200 Myr or as long as 800 Myr. Key Words: Origin of life-Astrobiology-Habitability-Biosignatures-Geochemistry-Early Earth. Astrobiology 18, 343-364.

  17. Narrow band imaging combined with water immersion technique in the diagnosis of celiac disease.

    PubMed

    Valitutti, Francesco; Oliva, Salvatore; Iorfida, Donatella; Aloi, Marina; Gatti, Silvia; Trovato, Chiara Maria; Montuori, Monica; Tiberti, Antonio; Cucchiara, Salvatore; Di Nardo, Giovanni

    2014-12-01

    The "multiple-biopsy" approach both in duodenum and bulb is the best strategy to confirm the diagnosis of celiac disease; however, this increases the invasiveness of the procedure itself and is time-consuming. To evaluate the diagnostic yield of a single biopsy guided by narrow-band imaging combined with water immersion technique in paediatric patients. Prospective assessment of the diagnostic accuracy of narrow-band imaging/water immersion technique-driven biopsy approach versus standard protocol in suspected celiac disease. The experimental approach correctly diagnosed 35/40 children with celiac disease, with an overall diagnostic sensitivity of 87.5% (95% CI: 77.3-97.7). An altered pattern of narrow-band imaging/water immersion technique endoscopic visualization was significantly associated with villous atrophy at guided biopsy (Spearman Rho 0.637, p<0.001). Concordance of narrow-band imaging/water immersion technique endoscopic assessments was high between two operators (K: 0.884). The experimental protocol was highly timesaving compared to the standard protocol. An altered narrow-band imaging/water immersion technique pattern coupled with high anti-transglutaminase antibodies could allow a single guided biopsy to diagnose celiac disease. When no altered mucosal pattern is visible even by narrow-band imaging/water immersion technique, multiple bulbar and duodenal biopsies should be obtained. Copyright © 2014. Published by Elsevier Ltd.

  18. Spectral narrowing and spin echo for localized carriers with heavy-tailed L evy distribution of hopping times

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yue, Z.; Mkhitaryan, Vagharsh; Raikh, M. E.

    2016-02-02

    We study analytically the free induction decay and the spin echo decay originating from the localized carriers moving between the sites which host random magnetic fields. Due to disorder in the site positions and energies, the on-site residence times, , are widely spread according to the L evy distribution. The power-law tail ∝ τ -1-∝ in the distribution of does not affect the conventional spectral narrowing for α > 2, but leads to a dramatic acceleration of the free induction decay in the domain 2 > α > 1. The next abrupt acceleration of the decay takes place as becomesmore » smaller than 1. In the latter domain the decay does not follow a simple-exponent law. To capture the behavior of the average spin in this domain, we solve the evolution equation for the average spin using the approach different from the conventional approach based on the Laplace transform. Unlike the free induction decay, the tail in the distribution of the residence times leads to the slow decay of the spin echo. The echo is dominated by realizations of the carrier motion for which the number of sites, visited by the carrier, is minimal.« less

  19. Using Stochastic Approximation Techniques to Efficiently Construct Confidence Intervals for Heritability.

    PubMed

    Schweiger, Regev; Fisher, Eyal; Rahmani, Elior; Shenhav, Liat; Rosset, Saharon; Halperin, Eran

    2018-06-22

    Estimation of heritability is an important task in genetics. The use of linear mixed models (LMMs) to determine narrow-sense single-nucleotide polymorphism (SNP)-heritability and related quantities has received much recent attention, due of its ability to account for variants with small effect sizes. Typically, heritability estimation under LMMs uses the restricted maximum likelihood (REML) approach. The common way to report the uncertainty in REML estimation uses standard errors (SEs), which rely on asymptotic properties. However, these assumptions are often violated because of the bounded parameter space, statistical dependencies, and limited sample size, leading to biased estimates and inflated or deflated confidence intervals (CIs). In addition, for larger data sets (e.g., tens of thousands of individuals), the construction of SEs itself may require considerable time, as it requires expensive matrix inversions and multiplications. Here, we present FIESTA (Fast confidence IntErvals using STochastic Approximation), a method for constructing accurate CIs. FIESTA is based on parametric bootstrap sampling, and, therefore, avoids unjustified assumptions on the distribution of the heritability estimator. FIESTA uses stochastic approximation techniques, which accelerate the construction of CIs by several orders of magnitude, compared with previous approaches as well as to the analytical approximation used by SEs. FIESTA builds accurate CIs rapidly, for example, requiring only several seconds for data sets of tens of thousands of individuals, making FIESTA a very fast solution to the problem of building accurate CIs for heritability for all data set sizes.

  20. Ring resonator based narrow-linewidth semiconductor lasers

    NASA Technical Reports Server (NTRS)

    Ksendzov, Alexander (Inventor)

    2005-01-01

    The present invention is a method and apparatus for using ring resonators to produce narrow linewidth hybrid semiconductor lasers. According to one embodiment of the present invention, the narrow linewidths are produced by combining the semiconductor gain chip with a narrow pass band external feedback element. The semi conductor laser is produced using a ring resonator which, combined with a Bragg grating, acts as the external feedback element. According to another embodiment of the present invention, the proposed integrated optics ring resonator is based on plasma enhanced chemical vapor deposition (PECVD) SiO.sub.2 /SiON/SiO.sub.2 waveguide technology.

  1. Fine-mapping and initial characterization of QT interval loci in African Americans.

    PubMed

    Avery, Christy L; Sethupathy, Praveen; Buyske, Steven; He, Qianchuan; Lin, Dan-Yu; Arking, Dan E; Carty, Cara L; Duggan, David; Fesinmeyer, Megan D; Hindorff, Lucia A; Jeff, Janina M; Klein, Liviu; Patton, Kristen K; Peters, Ulrike; Shohet, Ralph V; Sotoodehnia, Nona; Young, Alicia M; Kooperberg, Charles; Haiman, Christopher A; Mohlke, Karen L; Whitsel, Eric A; North, Kari E

    2012-01-01

    The QT interval (QT) is heritable and its prolongation is a risk factor for ventricular tachyarrhythmias and sudden death. Most genetic studies of QT have examined European ancestral populations; however, the increased genetic diversity in African Americans provides opportunities to narrow association signals and identify population-specific variants. We therefore evaluated 6,670 SNPs spanning eleven previously identified QT loci in 8,644 African American participants from two Population Architecture using Genomics and Epidemiology (PAGE) studies: the Atherosclerosis Risk in Communities study and Women's Health Initiative Clinical Trial. Of the fifteen known independent QT variants at the eleven previously identified loci, six were significantly associated with QT in African American populations (P≤1.20×10(-4)): ATP1B1, PLN1, KCNQ1, NDRG4, and two NOS1AP independent signals. We also identified three population-specific signals significantly associated with QT in African Americans (P≤1.37×10(-5)): one at NOS1AP and two at ATP1B1. Linkage disequilibrium (LD) patterns in African Americans assisted in narrowing the region likely to contain the functional variants for several loci. For example, African American LD patterns showed that 0 SNPs were in LD with NOS1AP signal rs12143842, compared with European LD patterns that indicated 87 SNPs, which spanned 114.2 Kb, were in LD with rs12143842. Finally, bioinformatic-based characterization of the nine African American signals pointed to functional candidates located exclusively within non-coding regions, including predicted binding sites for transcription factors such as TBX5, which has been implicated in cardiac structure and conductance. In this detailed evaluation of QT loci, we identified several African Americans SNPs that better define the association with QT and successfully narrowed intervals surrounding established loci. These results demonstrate that the same loci influence variation in QT across multiple

  2. Fine-Mapping and Initial Characterization of QT Interval Loci in African Americans

    PubMed Central

    Avery, Christy L.; Sethupathy, Praveen; Buyske, Steven; He, Qianchuan; Lin, Dan-Yu; Arking, Dan E.; Carty, Cara L.; Duggan, David; Fesinmeyer, Megan D.; Hindorff, Lucia A.; Jeff, Janina M.; Klein, Liviu; Patton, Kristen K.; Peters, Ulrike; Shohet, Ralph V.; Sotoodehnia, Nona; Young, Alicia M.; Kooperberg, Charles; Haiman, Christopher A.; Mohlke, Karen L.; Whitsel, Eric A.; North, Kari E.

    2012-01-01

    The QT interval (QT) is heritable and its prolongation is a risk factor for ventricular tachyarrhythmias and sudden death. Most genetic studies of QT have examined European ancestral populations; however, the increased genetic diversity in African Americans provides opportunities to narrow association signals and identify population-specific variants. We therefore evaluated 6,670 SNPs spanning eleven previously identified QT loci in 8,644 African American participants from two Population Architecture using Genomics and Epidemiology (PAGE) studies: the Atherosclerosis Risk in Communities study and Women's Health Initiative Clinical Trial. Of the fifteen known independent QT variants at the eleven previously identified loci, six were significantly associated with QT in African American populations (P≤1.20×10−4): ATP1B1, PLN1, KCNQ1, NDRG4, and two NOS1AP independent signals. We also identified three population-specific signals significantly associated with QT in African Americans (P≤1.37×10−5): one at NOS1AP and two at ATP1B1. Linkage disequilibrium (LD) patterns in African Americans assisted in narrowing the region likely to contain the functional variants for several loci. For example, African American LD patterns showed that 0 SNPs were in LD with NOS1AP signal rs12143842, compared with European LD patterns that indicated 87 SNPs, which spanned 114.2 Kb, were in LD with rs12143842. Finally, bioinformatic-based characterization of the nine African American signals pointed to functional candidates located exclusively within non-coding regions, including predicted binding sites for transcription factors such as TBX5, which has been implicated in cardiac structure and conductance. In this detailed evaluation of QT loci, we identified several African Americans SNPs that better define the association with QT and successfully narrowed intervals surrounding established loci. These results demonstrate that the same loci influence variation in QT across multiple

  3. Reasoning about real-time systems with temporal interval logic constraints on multi-state automata

    NASA Technical Reports Server (NTRS)

    Gabrielian, Armen

    1991-01-01

    Models of real-time systems using a single paradigm often turn out to be inadequate, whether the paradigm is based on states, rules, event sequences, or logic. A model-based approach to reasoning about real-time systems is presented in which a temporal interval logic called TIL is employed to define constraints on a new type of high level automata. The combination, called hierarchical multi-state (HMS) machines, can be used to model formally a real-time system, a dynamic set of requirements, the environment, heuristic knowledge about planning-related problem solving, and the computational states of the reasoning mechanism. In this framework, mathematical techniques were developed for: (1) proving the correctness of a representation; (2) planning of concurrent tasks to achieve goals; and (3) scheduling of plans to satisfy complex temporal constraints. HMS machines allow reasoning about a real-time system from a model of how truth arises instead of merely depending of what is true in a system.

  4. Representation of time interval entrained by periodic stimuli in the visual thalamus of pigeons

    PubMed Central

    Wang, Shu-Rong

    2017-01-01

    Animals use the temporal information from previously experienced periodic events to instruct their future behaviors. The retina and cortex are involved in such behavior, but it remains largely unknown how the thalamus, transferring visual information from the retina to the cortex, processes the periodic temporal patterns. Here we report that the luminance cells in the nucleus dorsolateralis anterior thalami (DLA) of pigeons exhibited oscillatory activities in a temporal pattern identical to the rhythmic luminance changes of repetitive light/dark (LD) stimuli with durations in the seconds-to-minutes range. Particularly, after LD stimulation, the DLA cells retained the entrained oscillatory activities with an interval closely matching the duration of the LD cycle. Furthermore, the post-stimulus oscillatory activities of the DLA cells were sustained without feedback inputs from the pallium (equivalent to the mammalian cortex). Our study suggests that the experience-dependent representation of time interval in the brain might not be confined to the pallial/cortical level, but may occur as early as at the thalamic level. PMID:29284554

  5. Most suitable mother wavelet for the analysis of fractal properties of stride interval time series via the average wavelet coefficient

    PubMed Central

    Zhang, Zhenwei; VanSwearingen, Jessie; Brach, Jennifer S.; Perera, Subashan

    2016-01-01

    Human gait is a complex interaction of many nonlinear systems and stride intervals exhibit self-similarity over long time scales that can be modeled as a fractal process. The scaling exponent represents the fractal degree and can be interpreted as a biomarker of relative diseases. The previous study showed that the average wavelet method provides the most accurate results to estimate this scaling exponent when applied to stride interval time series. The purpose of this paper is to determine the most suitable mother wavelet for the average wavelet method. This paper presents a comparative numerical analysis of sixteen mother wavelets using simulated and real fractal signals. Simulated fractal signals were generated under varying signal lengths and scaling exponents that indicate a range of physiologically conceivable fractal signals. The five candidates were chosen due to their good performance on the mean square error test for both short and long signals. Next, we comparatively analyzed these five mother wavelets for physiologically relevant stride time series lengths. Our analysis showed that the symlet 2 mother wavelet provides a low mean square error and low variance for long time intervals and relatively low errors for short signal lengths. It can be considered as the most suitable mother function without the burden of considering the signal length. PMID:27960102

  6. Ocular Biometrics of Myopic Eyes With Narrow Angles.

    PubMed

    Chong, Gabriel T; Wen, Joanne C; Su, Daniel Hsien-Wen; Stinnett, Sandra; Asrani, Sanjay

    2016-02-01

    The purpose of this study was to compare the ocular biometrics between myopic patients with and without narrow angles. Patients with a stable myopic refraction (myopia worse than -1.00 D spherical equivalent) were prospectively recruited. Angle status was assessed using gonioscopy and biometric measurements were performed using an anterior segment optical coherence tomography and an IOLMaster. A total of 29 patients (58 eyes) were enrolled with 13 patients (26 eyes) classified as having narrow angles and 16 patients (32 eyes) classified as having open angles. Baseline demographics of age, sex, and ethnicity did not differ significantly between the 2 groups. The patients with narrow angles were on average older than those with open angles but the difference did not reach statistical significance (P=0.12). The central anterior chamber depth was significantly less in the eyes with narrow angles (P=0.05). However, the average lens thickness, although greater in the eyes with narrow angles, did not reach statistical significance (P=0.10). Refractive error, axial lengths, and iris thicknesses did not differ significantly between the 2 groups (P=0.32, 0.47, 0.15). Narrow angles can occur in myopic eyes. Routine gonioscopy is therefore recommended for all patients regardless of refractive error.

  7. Intramyocardial arterial narrowing in dogs with subaortic stenosis.

    PubMed

    Falk, T; Jönsson, L; Pedersen, H D

    2004-09-01

    Earlier studies have described intramyocardial arterial narrowing based on hyperplasia and hypertrophy of the vessel wall in dogs with subaortic stenosis (SAS). In theory, such changes might increase the risk of sudden death, as they seem to do in heart disease in other species. This retrospective pathological study describes and quantifies intramyocardial arterial narrowing in 44 dogs with naturally occurring SAS and in eight control dogs. The majority of the dogs with SAS died suddenly (n=27); nine had died or been euthanased with signs of heart failure and eight were euthanased without clinical signs. Dogs with SAS had significantly narrower intramyocardial arteries (P<0.001) and more myocardial fibrosis (P<0.001) than control dogs. Male dogs and those with more severe hypertrophy had more vessel narrowing (P=0.02 and P=0.02, respectively), whereas dogs with dilated hearts had slightly less pronounced arterial thickening (P=0.01). Arterial narrowing was not related to age, but fibrosis increased with age (P=0.047). Dogs that died suddenly did not have a greater number of arterial changes than other dogs with SAS. This study suggests that most dogs with SAS have intramyocardial arterial narrowing and that the risk of dying suddenly is not significantly related to the overall degree of vessel obliteration.

  8. The influence of pretreatment characteristics and radiotherapy parameters on time interval to development of radiation-associated meningioma.

    PubMed

    Paulino, Arnold C; Ahmed, Irfan M; Mai, Wei Y; Teh, Bin S

    2009-12-01

    To identify pretreatment characteristics and radiotherapy parameters which may influence time interval to development of radiation-associated meningioma (RAM). A Medline/PUBMED search of articles dealing with RAM yielded 66 studies between 1981 and 2006. Factors analyzed included patient age and gender, type of initial tumor treated, radiotherapy (RT) dose and volume, and time interval from RT to development of RAM. A total of 143 patients with a median age at RT of 12 years form the basis of this report. The most common initial tumors or conditions treated with RT were medulloblastoma (n = 27), pituitary adenoma (n = 20), acute lymphoblastic leukemia (n = 20), low-grade astrocytoma (n = 19), and tinea capitis (n = 14). In the 116 patients whose RT fields were known, 55 (47.4%) had a portion of the brain treated, whereas 32 (27.6%) and 29 (25.0%) had craniospinal and whole-brain fields. The median time from RT to develop a RAM or latent time (LT) was 19 years (range, 1-63 years). Male gender (p = 0.001), initial diagnosis of leukemia (p = 0.001), and use of whole brain or craniospinal field (p time to develop a RAM was related to gender, initial tumor type, radiotherapy volume, and radiotherapy dose.

  9. The influence of age on gait parameters during the transition from a wide to a narrow pathway.

    PubMed

    Shkuratova, Nataliya; Taylor, Nicholas

    2008-06-01

    The ability to negotiate pathways of different widths is a prerequisite of daily living. However, only a few studies have investigated changes in gait parameters in response to walking on narrow pathways. The aim of this study is to examine the influence of age on gait adjustments during the transition from a wide to a narrow pathway. Two-group repeated measures design. Gait Laboratory. Twenty healthy older participants (mean [M] = 74.3 years, Standard deviation [SD] = 7.2 years); 20 healthy young participants (M = 26.6 years, SD = 6.1 years). Making the transition from walking on a wide pathway (68 cm) to walking on a narrow pathway (15 cm). Step length, step time, step width, double support time and base of support. Healthy older participants were able to make the transition from a wide to a narrow pathway successfully. There was only one significant interaction, between age and base of support (p < 0.003). Older adults decreased their base of support only when negotiating the transition step, while young participants started decreasing their base of support prior to the negotiation of transition step (p < 0.01). Adjustments to the transition from a wide to a narrow pathway are largely unaffected by normal ageing. Difficulties in making the transition to a narrow pathway during walking should not be attributed to normal age-related changes. (c) 2008 John Wiley & Sons, Ltd.

  10. Timing fungicide application intervals based on airborne Erysiphe necator concentrations

    USDA-ARS?s Scientific Manuscript database

    Management of grape powdery mildew (Erysiphe necator) and other polycyclic diseases relies on numerous fungicide applications that follow a calendar or model-based application intervals, both of which assume that inoculum is always present. Quantitative molecular assays have been previously develope...

  11. Narrow-linewidth Q-switched random distributed feedback fiber laser.

    PubMed

    Xu, Jiangming; Ye, Jun; Xiao, Hu; Leng, Jinyong; Wu, Jian; Zhang, Hanwei; Zhou, Pu

    2016-08-22

    A narrow-linewidth Q-switched random fiber laser (RFL) based on a half-opened cavity, which is realized by narrow-linewidth fiber Bragg grating (FBG) and a section of 3 km passive fiber, has been proposed and experimentally investigated. The narrow-linewidth lasing is generated by the spectral filtering of three FBGs with linewidth of 1.21 nm, 0.56 nm, and 0.12 nm, respectively. The Q switching of the distributed cavity is achieved by placing an acousto-optical modulator (AOM) between the FBG and the passive fiber. The maximal output powers of the narrow-linewidth RFLs with the three different FBGs are 0.54 W, 0.27 W, and 0.08 W, respectively. Furthermore, the repetition rates of the output pulses are 500 kHz, and the pulse durations are about 500 ns. The corresponding pulse energies are about 1.08 μJ, 0.54 μJ, and 0.16 μJ, accordingly. The linewidth of FBG can influence the output characteristics in full scale. The narrower the FBG, the higher the pump threshold; the lower the output power at the same pump level, the more serious the linewidth broadening; and thus the higher the proportion of the CW-ground exists in the output pulse trains. Thanks to the assistance of the band-pass filter (BPF), the proportion of the CW-ground of narrow-linewidth Q-switched RFL under the relative high-pump-low-output condition can be reduced effectively. The experimental results indicate that it is challenging to demonstrate a narrow-linewidth Q-switched RFL with high quality output. But further power scaling and linewidth narrowing is possible in the case of operating parameters, optimization efforts, and a more powerful pump source. To the best of our knowledge, this is the first demonstration of narrow-linewidth generation in a Q-switched RFL.

  12. Discovery of a narrow line quasar

    NASA Technical Reports Server (NTRS)

    Stocke, J.; Liebert, J.; Maccacaro, T.; Griffiths, R. E.; Steiner, J. E.

    1982-01-01

    A stellar object is reported which, while having X-ray and optical luminosities typical of quasars, has narrow permitted and forbidden emission lines over the observed spectral range. The narrow-line spectrum is high-excitation, the Balmer lines seem to be recombinational, and a redder optical spectrum than that of most quasars is exhibited, despite detection as a weak radio source. The object does not conform to the relationships between H-beta parameters and X-ray flux previously claimed for a large sample of the active galactic nuclei. Because reddish quasars with narrow lines, such as the object identified, may not be found by the standard techniques for the discovery of quasars, the object may be a prototype of a new class of quasars analogous to high-luminosity Seyfert type 2 galaxies. It is suggested that these objects cannot comprise more than 10% of all quasars.

  13. Infants Experience Perceptual Narrowing for Nonprimate Faces

    ERIC Educational Resources Information Center

    Simpson, Elizabeth A.; Varga, Krisztina; Frick, Janet E.; Fragaszy, Dorothy

    2011-01-01

    Perceptual narrowing--a phenomenon in which perception is broad from birth, but narrows as a function of experience--has previously been tested with primate faces. In the first 6 months of life, infants can discriminate among individual human and monkey faces. Though the ability to discriminate monkey faces is lost after about 9 months, infants…

  14. Delay-Dependent Stability Criterion for Bidirectional Associative Memory Neural Networks with Interval Time-Varying Delays

    NASA Astrophysics Data System (ADS)

    Park, Ju H.; Kwon, O. M.

    In the letter, the global asymptotic stability of bidirectional associative memory (BAM) neural networks with delays is investigated. The delay is assumed to be time-varying and belongs to a given interval. A novel stability criterion for the stability is presented based on the Lyapunov method. The criterion is represented in terms of linear matrix inequality (LMI), which can be solved easily by various optimization algorithms. Two numerical examples are illustrated to show the effectiveness of our new result.

  15. Narrow Networks On The Health Insurance Marketplaces: Prevalence, Pricing, And The Cost Of Network Breadth.

    PubMed

    Dafny, Leemore S; Hendel, Igal; Marone, Victoria; Ody, Christopher

    2017-09-01

    Anecdotal reports and systematic research highlight the prevalence of narrow-network plans on the Affordable Care Act's health insurance Marketplaces. At the same time, Marketplace premiums in the period 2014-16 were much lower than projected by the Congressional Budget Office in 2009. Using detailed data on the breadth of both hospital and physician networks, we studied the prevalence of narrow networks and quantified the association between network breadth and premiums. Controlling for many potentially confounding factors, we found that a plan with narrow physician and hospital networks was 16 percent cheaper than a plan with broad networks for both, and that narrowing the breadth of just one type of network was associated with a 6-9 percent decrease in premiums. Narrow-network plans also have a sizable impact on federal outlays, as they depress the premium of the second-lowest-price silver plan, to which subsidy amounts are linked. Holding all else constant, we estimate that federal subsidies would have been 10.8 percent higher in 2014 had Marketplaces required all plans to offer broad provider networks. Narrow networks are a promising source of potential savings for other segments of the commercial insurance market. Project HOPE—The People-to-People Health Foundation, Inc.

  16. The Influence of Pretreatment Characteristics and Radiotherapy Parameters on Time Interval to Development of Radiation-Associated Meningioma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paulino, Arnold C., E-mail: apaulino@tmhs.or; Ahmed, Irfan M.; Mai, Wei Y.

    2009-12-01

    Purpose: To identify pretreatment characteristics and radiotherapy parameters which may influence time interval to development of radiation-associated meningioma (RAM). Methods and Materials: A Medline/PUBMED search of articles dealing with RAM yielded 66 studies between 1981 and 2006. Factors analyzed included patient age and gender, type of initial tumor treated, radiotherapy (RT) dose and volume, and time interval from RT to development of RAM. Results: A total of 143 patients with a median age at RT of 12 years form the basis of this report. The most common initial tumors or conditions treated with RT were medulloblastoma (n = 27), pituitarymore » adenoma (n = 20), acute lymphoblastic leukemia (n = 20), low-grade astrocytoma (n = 19), and tinea capitis (n = 14). In the 116 patients whose RT fields were known, 55 (47.4%) had a portion of the brain treated, whereas 32 (27.6%) and 29 (25.0%) had craniospinal and whole-brain fields. The median time from RT to develop a RAM or latent time (LT) was 19 years (range, 1-63 years). Male gender (p = 0.001), initial diagnosis of leukemia (p = 0.001), and use of whole brain or craniospinal field (p <= 0.0001) were associated with a shorter LT, whereas patients who received lower doses of RT had a longer LT (p < 0.0001). Conclusions: The latent time to develop a RAM was related to gender, initial tumor type, radiotherapy volume, and radiotherapy dose.« less

  17. Effect of the time interval between fusion and activation on epigenetic reprogramming and development of bovine somatic cell nuclear transfer embryos.

    PubMed

    Liu, Jun; Wang, Yongsheng; Su, Jianmin; Wang, Lijun; Li, Ruizhe; Li, Qian; Wu, Yongyan; Hua, Song; Quan, Fusheng; Guo, Zekun; Zhang, Yong

    2013-04-01

    Previous studies have shown that the time interval between fusion and activation (FA interval) play an important role in nuclear remodeling and in vitro development of somatic cell nuclear transfer (SCNT) embryos. However, the effects of FA interval on the epigenetic reprogramming and in vivo developmental competence of SCNT embryos remain unknown. In the present study, the effects of different FA intervals (0 h, 2 h, and 4 h) on the epigenetic reprogramming and developmental competence of bovine SCNT embryos were assessed. The results demonstrated that H3 lysine 9 (H3K9ac) levels decreased rapidly after fusion in all three groups. H3K9ac was practically undetectable 2 h after fusion in the 2-h and 4-h FA interval groups. However, H3K9ac was still evidently detectable in the 0-h FA interval group. The H3K9ac levels increased 10 h after fusion in all three groups, but were higher in the 2-h and 4-h FA interval groups than that in the 0-h FA interval group. The methylation levels of the satellite I region in day-7 blastocysts derived from the 2-h or 4-h FA interval groups was similar to that of in vitro fertilization blastocysts and is significantly lower than that of the 0-h FA interval group. SCNT embryos derived from 2-h FA interval group showed higher developmental competence than those from the 0-h and 4-h FA interval groups in terms of cleavage rate, blastocyst formation rate, apoptosis index, and pregnancy and calving rates. Hence, the FA interval is an important factor influencing the epigenetic reprogramming and developmental competence of bovine SCNT embryos.

  18. Impact of heart disease and calibration interval on accuracy of pulse transit time-based blood pressure estimation.

    PubMed

    Ding, Xiaorong; Zhang, Yuanting; Tsang, Hon Ki

    2016-02-01

    Continuous blood pressure (BP) measurement without a cuff is advantageous for the early detection and prevention of hypertension. The pulse transit time (PTT) method has proven to be promising for continuous cuffless BP measurement. However, the problem of accuracy is one of the most challenging aspects before the large-scale clinical application of this method. Since PTT-based BP estimation relies primarily on the relationship between PTT and BP under certain assumptions, estimation accuracy will be affected by cardiovascular disorders that impair this relationship and by the calibration frequency, which may violate these assumptions. This study sought to examine the impact of heart disease and the calibration interval on the accuracy of PTT-based BP estimation. The accuracy of a PTT-BP algorithm was investigated in 37 healthy subjects and 48 patients with heart disease at different calibration intervals, namely 15 min, 2 weeks, and 1 month after initial calibration. The results showed that the overall accuracy of systolic BP estimation was significantly lower in subjects with heart disease than in healthy subjects, but diastolic BP estimation was more accurate in patients than in healthy subjects. The accuracy of systolic and diastolic BP estimation becomes less reliable with longer calibration intervals. These findings demonstrate that both heart disease and the calibration interval can influence the accuracy of PTT-based BP estimation and should be taken into consideration to improve estimation accuracy.

  19. Fourth-grade children's dietary recall accuracy is influenced by retention interval (target period and interview time).

    PubMed

    Baxter, Suzanne Domel; Hardin, James W; Guinn, Caroline H; Royer, Julie A; Mackelprang, Alyssa J; Smith, Albert F

    2009-05-01

    For a 24-hour dietary recall, two possible target periods are the prior 24 hours (24 hours immediately preceding the interview time) and previous day (midnight to midnight of the day before the interview), and three possible interview times are morning, afternoon, and evening. Target period and interview time determine the retention interval (elapsed time between to-be-reported meals and the interview), which, along with intervening meals, can influence reporting accuracy. The effects of target period and interview time on children's accuracy for reporting school meals during 24-hour dietary recalls were investigated. DESIGN AND SUBJECTS/SETTING: During the 2004-2005, 2005-2006, and 2006-2007 school years in Columbia, SC, each of 374 randomly selected fourth-grade children (96% African American) was observed eating two consecutive school meals (breakfast and lunch) and interviewed to obtain a 24-hour dietary recall using one of six conditions defined by crossing two target periods with three interview times. Each condition had 62 or 64 children (half boys). Accuracy for reporting school meals was quantified by calculating rates for omissions (food items observed eaten but unreported) and intrusions (food items reported eaten but unobserved); a measure of total inaccuracy combined errors for reporting food items and amounts. For each accuracy measure, analysis of variance was conducted with target period, interview time, their interaction, sex, interviewer, and school year in the model. There was a target-period effect and a target-period by interview-time interaction on omission rates, intrusion rates, and total inaccuracy (six P values <0.004). For prior-24-hour recalls compared to previous-day recalls, and for prior-24-hour recalls in the afternoon and evening compared to previous-day recalls in the afternoon and evening, omission rates were better by one third, intrusion rates were better by one half, and total inaccuracy was better by one third. To enhance

  20. Adaptive Changes After 2 Weeks of 10-s Sprint Interval Training With Various Recovery Times.

    PubMed

    Olek, Robert A; Kujach, Sylwester; Ziemann, Ewa; Ziolkowski, Wieslaw; Waz, Piotr; Laskowski, Radoslaw

    2018-01-01

    Purpose: The aim of this study was to compare the effect of applying two different rest recovery times in a 10-s sprint interval training session on aerobic and anaerobic capacities as well as skeletal muscle enzyme activities. Methods: Fourteen physically active but not highly trained male subjects (mean maximal oxygen uptake 50.5 ± 1.0 mlO 2 ·kg -1 ·min -1 ) participated in the study. The training protocol involved a series of 10-s sprints separated by either 1-min (SIT10:1) or 4-min (SIT10:4) of recovery. The number of sprints progressed from four to six over six sessions separated by 1-2 days rest. Pre and post intervention anthropometric measurements, assessment of aerobic, anaerobic capacity and muscle biopsy were performed. In the muscle samples maximal activities of citrate synthase (CS), 3-hydroxyacylCoA dehydrogenase (HADH), carnitine palmitoyl-transferase (CPT), malate dehydrogenase (MDH), and its mitochondrial form (mMDH), as well as lactate dehydrogenase (LDH) were determined. Analysis of variance was performed to determine changes between conditions. Results: Maximal oxygen uptake improved significantly in both training groups, by 13.6% in SIT10:1 and 11.9% in SIT10:4, with no difference between groups. Wingate anaerobic test results indicated main effect of time for total work, peak power output and mean power output, which increased significantly and similarly in both groups. Significant differences between training groups were observed for end power output, which increased by 10.8% in SIT10:1, but remained unchanged in SIT10:4. Both training protocols induced similar increase in CS activity (main effect of time p < 0.05), but no other enzymes. Conclusion: Sprint interval training protocols induce metabolic adaptation over a short period of time, and the reduced recovery between bouts may attenuate fatigue during maximal exercise.

  1. The application of the analog signal to discrete time interval converter to the signal conditioner power supplies

    NASA Technical Reports Server (NTRS)

    Schoenfeld, A. D.; Yu, Y.

    1973-01-01

    The Analog Signal to Discrete Time Interval Converter microminiaturized module was utilized to control the signal conditioner power supplies. The multi-loop control provides outstanding static and dynamic performance characteristics, exceeding those generally associated with single-loop regulators. Eight converter boards, each containing three independent dc to dc converter, were built, tested, and delivered.

  2. Voter model with non-Poissonian interevent intervals

    NASA Astrophysics Data System (ADS)

    Takaguchi, Taro; Masuda, Naoki

    2011-09-01

    Recent analysis of social communications among humans has revealed that the interval between interactions for a pair of individuals and for an individual often follows a long-tail distribution. We investigate the effect of such a non-Poissonian nature of human behavior on dynamics of opinion formation. We use a variant of the voter model and numerically compare the time to consensus of all the voters with different distributions of interevent intervals and different networks. Compared with the exponential distribution of interevent intervals (i.e., the standard voter model), the power-law distribution of interevent intervals slows down consensus on the ring. This is because of the memory effect; in the power-law case, the expected time until the next update event on a link is large if the link has not had an update event for a long time. On the complete graph, the consensus time in the power-law case is close to that in the exponential case. Regular graphs bridge these two results such that the slowing down of the consensus in the power-law case as compared to the exponential case is less pronounced as the degree increases.

  3. Narrow-Line Seyfert 1 Galaxies

    NASA Technical Reports Server (NTRS)

    Leighly, Karen M.

    2000-01-01

    The primary work during this year has been the analysis and interpretation of our HST spectra from two extreme Narrow-line Seyfert 1 galaxies (NLS1s) Infrared Astronomy Satellite (IRAS) 13224-3809 and 1H 0707-495. This work has been presented as an invited talk at the workshop entitled "Observational and theoretical progress in the Study of Narrow-line Seyfert 1 Galaxies" held in Bad Honnef, Germany December 8-11, as a contributed talk at the January 2000 AAS meeting in Atlanta, Georgia, and as a contributed talk at the workshop "Probing the Physics of Active Galactic Nuclei by Multiwavelength Monitoring" held at Goddard Space Flight Center June 20-22, 2000.

  4. Assessing the Impact of Different Measurement Time Intervals on Observed Long-Term Wind Speed Trends

    NASA Astrophysics Data System (ADS)

    Azorin-Molina, C.; Vicente-Serrano, S. M.; McVicar, T.; Jerez, S.; Revuelto, J.; López Moreno, J. I.

    2014-12-01

    During the last two decades climate studies have reported a tendency toward a decline in measured near-surface wind speed in some regions of Europe, North America, Asia and Australia. This weakening in observed wind speed has been recently termed "global stilling", showing a worldwide average trend of -0.140 m s-1 dec-1 during last 50-years. The precise cause of the "global stilling" remains largely uncertain and has been hypothetically attributed to several factors, mainly related to: (i) an increasing surface roughness (i.e. forest growth, land use changes, and urbanization); (ii) a slowdown in large-scale atmospheric circulation; (iii) instrumental drifts and technological improvements, maintenance, and shifts in measurements sites and calibration issues; (iv) sunlight dimming due to air pollution; and (v) astronomical changes. This study proposed a novel investigation aimed at analyzing how different measurement time intervals used to calculate a wind speed series can affect the sign and magnitude of long-term wind speed trends. For instance, National Weather Services across the globe estimate daily average wind speed using different time intervals and formulae that may affect the trend results. Firstly, we carried out a comprehensive review of wind studies reporting the sign and magnitude of wind speed trend and the sampling intervals used. Secondly, we analyzed near-surface wind speed trends recorded at 59 land-based stations across Spain comparing monthly mean wind speed series obtained from: (a) daily mean wind speed data averaged from standard 10-min mean observations at 0000, 0700, 1300 and 1800 UTC; and (b) average wind speed of 24 hourly measurements (i.e., wind run measurements) from 0000 to 2400 UTC. Thirdly and finally, we quantified the impact of anemometer drift (i.e. bearing malfunction) by presenting preliminary results (1-year of paired measurements) from a comparison of one new anemometer sensor against one malfunctioned anenometer sensor due

  5. Effects of cooling interval and MnO2, TiO2, CdO, NiO additions on spheluritic willemite crystals

    NASA Astrophysics Data System (ADS)

    Coşkun, Nihal Derin; Uz, Veli; Issi, Ali; Genç, Soner; Çakı, Münevver

    2017-01-01

    Macro crystal production in crystal glaze systems is a very important topic in ceramic art and science. In this study, crystal growth was obtained in two different firing regimes. Recipes were prepared by adding MnO, TiO, NiO and CdO into the frit. The first firing regime, which is used in artistic ceramics, has a 100 °C cooling temperature interval. The second regime that has a 580 °C cooling temperature interval, was determined by DTA analysis. Then, the development of crystals was compared between these two firing regimes. According to the results, spheluritic willemite crystals up to three cm in the glazes doped MnO2 have been obtained by cooling it in a wide cooling interval. Larger willemite crystals were not formed in the narrow cooling temperature interval. It was determined that larger crystals can be produced by cooling at wide cooling temperature intervals and holding at lower temperature which involves nucleating the temperature of the crystal.

  6. Thirty Meter Telescope (TMT) Narrow Field Infrared Adaptive Optics System (NFIRAOS) real-time controller preliminary architecture

    NASA Astrophysics Data System (ADS)

    Kerley, Dan; Smith, Malcolm; Dunn, Jennifer; Herriot, Glen; Véran, Jean-Pierre; Boyer, Corinne; Ellerbroek, Brent; Gilles, Luc; Wang, Lianqi

    2016-08-01

    The Narrow Field Infrared Adaptive Optics System (NFIRAOS) is the first light Adaptive Optics (AO) system for the Thirty Meter Telescope (TMT). A critical component of NFIRAOS is the Real-Time Controller (RTC) subsystem which provides real-time wavefront correction by processing wavefront information to compute Deformable Mirror (DM) and Tip/Tilt Stage (TTS) commands. The National Research Council of Canada - Herzberg (NRC-H), in conjunction with TMT, has developed a preliminary design for the NFIRAOS RTC. The preliminary architecture for the RTC is comprised of several Linux-based servers. These servers are assigned various roles including: the High-Order Processing (HOP) servers, the Wavefront Corrector Controller (WCC) server, the Telemetry Engineering Display (TED) server, the Persistent Telemetry Storage (PTS) server, and additional testing and spare servers. There are up to six HOP servers that accept high-order wavefront pixels, and perform parallelized pixel processing and wavefront reconstruction to produce wavefront corrector error vectors. The WCC server performs low-order mode processing, and synchronizes and aggregates the high-order wavefront corrector error vectors from the HOP servers to generate wavefront corrector commands. The Telemetry Engineering Display (TED) server is the RTC interface to TMT and other subsystems. The TED server receives all external commands and dispatches them to the rest of the RTC servers and is responsible for aggregating several offloading and telemetry values that are reported to other subsystems within NFIRAOS and TMT. The TED server also provides the engineering GUIs and real-time displays. The Persistent Telemetry Storage (PTS) server contains fault tolerant data storage that receives and stores telemetry data, including data for Point-Spread Function Reconstruction (PSFR).

  7. Confidence intervals for the population mean tailored to small sample sizes, with applications to survey sampling.

    PubMed

    Rosenblum, Michael A; Laan, Mark J van der

    2009-01-07

    The validity of standard confidence intervals constructed in survey sampling is based on the central limit theorem. For small sample sizes, the central limit theorem may give a poor approximation, resulting in confidence intervals that are misleading. We discuss this issue and propose methods for constructing confidence intervals for the population mean tailored to small sample sizes. We present a simple approach for constructing confidence intervals for the population mean based on tail bounds for the sample mean that are correct for all sample sizes. Bernstein's inequality provides one such tail bound. The resulting confidence intervals have guaranteed coverage probability under much weaker assumptions than are required for standard methods. A drawback of this approach, as we show, is that these confidence intervals are often quite wide. In response to this, we present a method for constructing much narrower confidence intervals, which are better suited for practical applications, and that are still more robust than confidence intervals based on standard methods, when dealing with small sample sizes. We show how to extend our approaches to much more general estimation problems than estimating the sample mean. We describe how these methods can be used to obtain more reliable confidence intervals in survey sampling. As a concrete example, we construct confidence intervals using our methods for the number of violent deaths between March 2003 and July 2006 in Iraq, based on data from the study "Mortality after the 2003 invasion of Iraq: A cross sectional cluster sample survey," by Burnham et al. (2006).

  8. 2. Photocopied July 1971 from photostat Jordan Narrows Folder #1, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. Photocopied July 1971 from photostat Jordan Narrows Folder #1, Engineering Department, Utah Power and Light Co., Salt Lake City, Utah. JORDAN NARROWS STATION. PLAN AND SECTION. - Salt Lake City Water & Electrical Power Company, Jordan Narrows Hydroelectric Plant, Jordan River, Riverton, Salt Lake County, UT

  9. The X-ray spectrum and time variability of narrow emission line galaxies

    NASA Technical Reports Server (NTRS)

    Mushotzky, R.

    1981-01-01

    X-ray spectral and temporal observations are reported for six narrow emission line galaxies (NELGs), all of which are fitted by power-law X-ray spectra of energy slope 0.8 and have column densities in the line of sight greater than 1 x 10 to the 22nd atoms/sq cm. Three of the objects, NGC 526a, NGC 2110 and MCG-5-23-16 are variable in their X-ray flux, and the latter two, along with NGC 5506 and NGC 7582, showed detectable variability in at least one observation. The measured X-ray properties of these NELGs, which also included NGC 2992, strongly resemble those of previously-measured type 1 Seyferts of the same X-ray luminosity and lead to the conclusion of great similarity between the NELGs and low-luminosity type 1 Seyferts. The implications of these observations for the optical line-emitting region structure of these galaxies are discussed.

  10. Mice plan decision strategies based on previously learned time intervals, locations, and probabilities

    PubMed Central

    Tosun, Tuğçe; Gür, Ezgi; Balcı, Fuat

    2016-01-01

    Animals can shape their timed behaviors based on experienced probabilistic relations in a nearly optimal fashion. On the other hand, it is not clear if they adopt these timed decisions by making computations based on previously learnt task parameters (time intervals, locations, and probabilities) or if they gradually develop their decisions based on trial and error. To address this question, we tested mice in the timed-switching task, which required them to anticipate when (after a short or long delay) and at which of the two delay locations a reward would be presented. The probability of short trials differed between test groups in two experiments. Critically, we first trained mice on relevant task parameters by signaling the active trial with a discriminative stimulus and delivered the corresponding reward after the associated delay without any response requirement (without inducing switching behavior). During the test phase, both options were presented simultaneously to characterize the emergence and temporal characteristics of the switching behavior. Mice exhibited timed-switching behavior starting from the first few test trials, and their performance remained stable throughout testing in the majority of the conditions. Furthermore, as the probability of the short trial increased, mice waited longer before switching from the short to long location (experiment 1). These behavioral adjustments were in directions predicted by reward maximization. These results suggest that rather than gradually adjusting their time-dependent choice behavior, mice abruptly adopted temporal decision strategies by directly integrating their previous knowledge of task parameters into their timed behavior, supporting the model-based representational account of temporal risk assessment. PMID:26733674

  11. Measurement of trained speech patterns in stuttering: interjudge and intrajudge agreement of experts by means of modified time-interval analysis.

    PubMed

    Alpermann, Anke; Huber, Walter; Natke, Ulrich; Willmes, Klaus

    2010-09-01

    Improved fluency after stuttering therapy is usually measured by the percentage of stuttered syllables. However, outcome studies rarely evaluate the use of trained speech patterns that speakers use to manage stuttering. This study investigated whether the modified time interval analysis can distinguish between trained speech patterns, fluent speech, and stuttered speech. Seventeen German experts on stuttering judged a speech sample on two occasions. Speakers of the sample were stuttering adults, who were not undergoing therapy, as well as participants in a fluency shaping and a stuttering modification therapy. Results showed satisfactory inter-judge and intra-judge agreement above 80%. Intervals with trained speech patterns were identified as consistently as stuttered and fluent intervals. We discuss limitations of the study, as well as implications of our findings for the development of training for identification of trained speech patterns and future outcome studies. The reader will be able to (a) explain different methods to measure the use of trained speech patterns, (b) evaluate whether German experts are able to discriminate intervals with trained speech patterns reliably from fluent and stuttered intervals and (c) describe how the measurement of trained speech patterns can contribute to outcome studies.

  12. Initial Systolic Time Interval (ISTI) as a Predictor of Intradialytic Hypotension (IDH)

    NASA Astrophysics Data System (ADS)

    Biesheuvel, J. D.; Vervloet, M. G.; Verdaasdonk, R. M.; Meijer, J. H.

    2013-04-01

    In haemodialysis treatment the clearance and volume control by the kidneys of a patient are partially replaced by intermittent haemodialysis. Because this artificial process is performed on a limited time scale, unphysiological imbalances in the fluid compartments of the body occur, that can lead to intradialytic hypotensions (IDH). An IDH endangers the efficacy of the haemodialysis session and is associated with dismal clinical endpoints, including mortality. A diagnostic method that predicts the occurrence of these drops in blood pressure could facilitate timely measures for the prevention of IDH. The present study investigates whether the Initial Systolic Time Interval (ISTI) can provide such a diagnostic method. The ISTI is defined as the time difference between the R-peak in the electrocardiogram (ECG) and the C-wave in the impedance cardiogram (ICG) and is considered to be a non-invasive assessment of the time delay between the electrical and mechanical activity of the heart. This time delay has previously been found to depend on autonomic nervous function as well as preload of the heart. Therefore, it can be expected that ISTI may predict an imminent IDH caused by a low circulating blood volume. This ongoing observational clinical study investigates the relationship between changes in ISTI and subsequent drops in blood pressure during haemodialysis. A registration of a complicated dialysis showed a significant correlation between a drop in blood pressure, a decrease in relative blood volume and a substantial increase in ISTI. An uncomplicated dialysis, in which also a considerable amount of fluid was removed, showed no correlations. Both, blood pressure and ISTI remained stable. In conclusion, the preliminary results of the present study show a substantial response of ISTI to haemodynamic instability, indicating an application in optimization and individualisation of the dialysis process.

  13. Intercalibration of radioisotopic and astrochronologic time scales for the Cenomanian-Turonian boundary interval, western interior Basin, USA

    USGS Publications Warehouse

    Meyers, S.R.; Siewert, S.E.; Singer, B.S.; Sageman, B.B.; Condon, D.J.; Obradovich, J.D.; Jicha, B.R.; Sawyer, D.A.

    2012-01-01

    We develop an intercalibrated astrochronologic and radioisotopic time scale for the Cenomanian-Turonian boundary (CTB) interval near the Global Stratotype Section and Point in Colorado, USA, where orbitally influenced rhythmic strata host bentonites that contain sanidine and zircon suitable for 40Ar/ 39Ar and U-Pb dating. Paired 40Ar/ 39Ar and U-Pb ages are determined from four bentonites that span the Vascoceras diartianum to Pseudaspidoceras flexuosum ammonite biozones, utilizing both newly collected material and legacy sanidine samples of J. Obradovich. Comparison of the 40Ar/ 39Ar and U-Pb results underscores the strengths and limitations of each system, and supports an astronomically calibrated Fish Canyon sanidine standard age of 28.201 Ma. The radioisotopic data and published astrochronology are employed to develop a new CTB time scale, using two statistical approaches: (1) a simple integration that yields a CTB age of 93.89 ?? 0.14 Ma (2??; total radioisotopic uncertainty), and (2) a Bayesian intercalibration that explicitly accounts for orbital time scale uncertainty, and yields a CTB age of 93.90 ?? 0.15 Ma (95% credible interval; total radioisotopic and orbital time scale uncertainty). Both approaches firmly anchor the floating orbital time scale, and the Bayesian technique yields astronomically recalibrated radioisotopic ages for individual bentonites, with analytical uncertainties at the permil level of resolution, and total uncertainties below 2???. Using our new results, the duration between the Cenomanian-Turonian and the Cretaceous-Paleogene boundaries is 27.94 ?? 0.16 Ma, with an uncertainty of less than one-half of a long eccentricity cycle. ?? 2012 Geological Society of America.

  14. An enhanced narrow-band imaging method for the microvessel detection

    NASA Astrophysics Data System (ADS)

    Yu, Feng; Song, Enmin; Liu, Hong; Wan, Youming; Zhu, Jun; Hung, Chih-Cheng

    2018-02-01

    A medical endoscope system combined with the narrow-band imaging (NBI), has been shown to be a superior diagnostic tool for early cancer detection. The NBI can reveal the morphologic changes of microvessels in the superficial cancer. In order to improve the conspicuousness of microvessel texture, we propose an enhanced NBI method to improve the conspicuousness of endoscopic images. To obtain the more conspicuous narrow-band images, we use the edge operator to extract the edge information of the narrow-band blue and green images, and give a weight to the extracted edges. Then, the weighted edges are fused with the narrow-band blue and green images. Finally, the displayed endoscopic images are reconstructed with the enhanced narrow-band images. In addition, we evaluate the performance of enhanced narrow-band images with different edge operators. Experimental results indicate that the Sobel and Canny operators achieve the best performance of all. Compared with traditional NBI method of Olympus company, our proposed method has more conspicuous texture of microvessel.

  15. A Comparison of Momentary Time Sampling and Partial-Interval Recording for Assessment of Effects of Social Skills Training

    ERIC Educational Resources Information Center

    Radley, Keith C.; O'Handley, Roderick D.; Labrot, Zachary C.

    2015-01-01

    Assessment in social skills training often utilizes procedures such as partial-interval recording (PIR) and momentary time sampling (MTS) to estimate changes in duration in social engagements due to intervention. Although previous research suggests PIR to be more inaccurate than MTS in estimating levels of behavior, treatment analysis decisions…

  16. Acquisition and visualization techniques for narrow spectral color imaging.

    PubMed

    Neumann, László; García, Rafael; Basa, János; Hegedüs, Ramón

    2013-06-01

    This paper introduces a new approach in narrow-band imaging (NBI). Existing NBI techniques generate images by selecting discrete bands over the full visible spectrum or an even wider spectral range. In contrast, here we perform the sampling with filters covering a tight spectral window. This image acquisition method, named narrow spectral imaging, can be particularly useful when optical information is only available within a narrow spectral window, such as in the case of deep-water transmittance, which constitutes the principal motivation of this work. In this study we demonstrate the potential of the proposed photographic technique on nonunderwater scenes recorded under controlled conditions. To this end three multilayer narrow bandpass filters were employed, which transmit at 440, 456, and 470 nm bluish wavelengths, respectively. Since the differences among the images captured in such a narrow spectral window can be extremely small, both image acquisition and visualization require a novel approach. First, high-bit-depth images were acquired with multilayer narrow-band filters either placed in front of the illumination or mounted on the camera lens. Second, a color-mapping method is proposed, using which the input data can be transformed onto the entire display color gamut with a continuous and perceptually nearly uniform mapping, while ensuring optimally high information content for human perception.

  17. Associations between narrow angle and adult anthropometry: the Liwan Eye Study.

    PubMed

    Jiang, Yuzhen; He, Mingguang; Friedman, David S; Khawaja, Anthony P; Lee, Pak Sang; Nolan, Winifred P; Yin, Qiuxia; Foster, Paul J

    2014-06-01

    To assess the associations between narrow angle and adult anthropometry. Chinese adults aged 50 years and older were recruited from a population-based survey in the Liwan District of Guangzhou, China. Narrow angle was defined as the posterior trabecular meshwork not visible under static gonioscopy in at least three quadrants (i.e. a circumference of at least 270°). Logistic regression models were used to examine the associations between narrow angle and anthropomorphic measures (height, weight and body mass index, BMI). Among the 912 participants, lower weight, shorter height, and lower BMI were significantly associated with narrower angle width (tests for trend: mean angle width in degrees vs weight p < 0.001; vs height p < 0.001; vs BMI p = 0.012). In univariate analyses, shorter height, lower weight and lower BMI were all significantly associated with greater odds of narrow angle. The crude association between height and narrow angle was largely attributable to a stronger association with age and sex. Lower BMI and weight remained significantly associated with narrow angle after adjustment for height, age, sex, axial ocular biometric measures and education. In analyses stratified by sex, the association between BMI and narrow angle was only observed in women. Lower BMI and weight were associated with significantly greater odds of narrow angle after adjusting for age, education, axial ocular biometric measures and height. The odds of narrow angle increased 7% per 1 unit decrease in BMI. This association was most evident in women.

  18. Optically trapped atomic resonant devices for narrow linewidth spectral imaging

    NASA Astrophysics Data System (ADS)

    Qian, Lipeng

    absorption and fluorescence. The optimum resolution of the fluorescent image is predicted by simulation. Radiation trapping is also shown to be useful for the generation of ultra-narrow linewidth light from an atomic vapor flash lamp. A 2 nanosecond, high voltage pulse is used to excite low pressure mercury vapor mixed with noble gases, producing high intensity emission at the mercury resonant line at 253.7 nm. With a nanosecond pumping time and high electrical current, the radiation intensity of the mercury discharge is increased significantly compared to a normal glow discharge lamp, while simultaneously suppressing the formation of an arc discharge. By avoiding the arc discharge, discrete spectral lines of mercury were kept at narrow bandwidth. Due to radiation trapping, the emission linewidth from the nanosecond mercury lamp decreases with time and produces ultra-narrow linewidth emission 100 ns after of the excitation, this linewidth is verified by absorption measurements through low pressure mercury absorption filter. The lamp is used along with mercury absorption filters for spectroscopic applications, including Filtered Rayleigh Scattering with different CO2 pressures and Raman scattering from methanol.

  19. CI2 for creating and comparing confidence-intervals for time-series bivariate plots.

    PubMed

    Mullineaux, David R

    2017-02-01

    Currently no method exists for calculating and comparing the confidence-intervals (CI) for the time-series of a bivariate plot. The study's aim was to develop 'CI2' as a method to calculate the CI on time-series bivariate plots, and to identify if the CI between two bivariate time-series overlap. The test data were the knee and ankle angles from 10 healthy participants running on a motorised standard-treadmill and non-motorised curved-treadmill. For a recommended 10+ trials, CI2 involved calculating 95% confidence-ellipses at each time-point, then taking as the CI the points on the ellipses that were perpendicular to the direction vector between the means of two adjacent time-points. Consecutive pairs of CI created convex quadrilaterals, and any overlap of these quadrilaterals at the same time or ±1 frame as a time-lag calculated using cross-correlations, indicated where the two time-series differed. CI2 showed no group differences between left and right legs on both treadmills, but the same legs between treadmills for all participants showed differences of less knee extension on the curved-treadmill before heel-strike. To improve and standardise the use of CI2 it is recommended to remove outlier time-series, use 95% confidence-ellipses, and scale the ellipse by the fixed Chi-square value as opposed to the sample-size dependent F-value. For practical use, and to aid in standardisation or future development of CI2, Matlab code is provided. CI2 provides an effective method to quantify the CI of bivariate plots, and to explore the differences in CI between two bivariate time-series. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Hot Wax Sweeps Debris From Narrow Passages

    NASA Technical Reports Server (NTRS)

    Ricklefs, Steven K.

    1990-01-01

    Safe and effective technique for removal of debris and contaminants from narrow passages involves entrainment of undesired material in thermoplastic casting material. Semisolid wax slightly below melting temperature pushed along passage by pressurized nitrogen to remove debris. Devised to clean out fuel passages in main combustion chamber of Space Shuttle main engine. Also applied to narrow, intricate passages in internal-combustion-engine blocks, carburetors, injection molds, and other complicated parts.

  1. Systolic time interval v heart rate regression equations using atropine: reproducibility studies.

    PubMed Central

    Kelman, A W; Sumner, D J; Whiting, B

    1981-01-01

    1. Systolic time intervals (STI) were recorded in six normal male subjects over a period of 3 weeks. On one day per week, each subject received incremental doses of atropine intravenously to increase heart rate, allowing the determination of individual STI v HR regression equations. On the other days STI were recorded with the subjects resting, in the supine position. 2. There were highly significant regression relationships between heart rate and both LVET and QS2, but not between heart rate and PEP. 3. The regression relationships showed little intra-subject variability, but a large degree of inter-subject variability: they proved adequate to correct the STI for the daily fluctuations in heart rate. 4. Administration of small doses of atropine intravenously provides a satisfactory and convenient method of deriving individual STI v HR regression equations which can be applied over a period of weeks. PMID:7248136

  2. Systolic time interval v heart rate regression equations using atropine: reproducibility studies.

    PubMed

    Kelman, A W; Sumner, D J; Whiting, B

    1981-07-01

    1. Systolic time intervals (STI) were recorded in six normal male subjects over a period of 3 weeks. On one day per week, each subject received incremental doses of atropine intravenously to increase heart rate, allowing the determination of individual STI v HR regression equations. On the other days STI were recorded with the subjects resting, in the supine position. 2. There were highly significant regression relationships between heart rate and both LVET and QS2, but not between heart rate and PEP. 3. The regression relationships showed little intra-subject variability, but a large degree of inter-subject variability: they proved adequate to correct the STI for the daily fluctuations in heart rate. 4. Administration of small doses of atropine intravenously provides a satisfactory and convenient method of deriving individual STI v HR regression equations which can be applied over a period of weeks.

  3. Fracture strength and probability of survival of narrow and extra-narrow dental implants after fatigue testing: In vitro and in silico analysis.

    PubMed

    Bordin, Dimorvan; Bergamo, Edmara T P; Fardin, Vinicius P; Coelho, Paulo G; Bonfante, Estevam A

    2017-07-01

    To assess the probability of survival (reliability) and failure modes of narrow implants with different diameters. For fatigue testing, 42 implants with the same macrogeometry and internal conical connection were divided, according to diameter, as follows: narrow (Ø3.3×10mm) and extra-narrow (Ø2.9×10mm) (21 per group). Identical abutments were torqued to the implants and standardized maxillary incisor crowns were cemented and subjected to step-stress accelerated life testing (SSALT) in water. The use-level probability Weibull curves, and reliability for a mission of 50,000 and 100,000 cycles at 50N, 100, 150 and 180N were calculated. For the finite element analysis (FEA), two virtual models, simulating the samples tested in fatigue, were constructed. Loading at 50N and 100N were applied 30° off-axis at the crown. The von-Mises stress was calculated for implant and abutment. The beta (β) values were: 0.67 for narrow and 1.32 for extra-narrow implants, indicating that failure rates did not increase with fatigue in the former, but more likely were associated with damage accumulation and wear-out failures in the latter. Both groups showed high reliability (up to 97.5%) at 50 and 100N. A decreased reliability was observed for both groups at 150 and 180N (ranging from 0 to 82.3%), but no significant difference was observed between groups. Failure predominantly involved abutment fracture for both groups. FEA at 50N-load, Ø3.3mm showed higher von-Mises stress for abutment (7.75%) and implant (2%) when compared to the Ø2.9mm. There was no significant difference between narrow and extra-narrow implants regarding probability of survival. The failure mode was similar for both groups, restricted to abutment fracture. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Associations between Narrow Angle and Adult Anthropometry: The Liwan Eye Study

    PubMed Central

    Jiang, Yuzhen; He, Mingguang; Friedman, David S.; Khawaja, Anthony P.; Lee, Pak Sang; Nolan, Winifred P.; Yin, Qiuxia; Foster, Paul J.

    2015-01-01

    Purpose To assess the associations between narrow angle and adult anthropometry. Methods Chinese adults aged 50 years and older were recruited from a population-based survey in the Liwan District of Guangzhou, China. Narrow angle was defined as the posterior trabecular meshwork not visible under static gonioscopy in at least three quadrants (i.e. a circumference of at least 270°). Logistic regression models were used to examine the associations between narrow angle and anthropomorphic measures (height, weight and body mass index, BMI). Results Among the 912 participants, lower weight, shorter height, and lower BMI were significantly associated with narrower angle width (tests for trend: mean angle width in degrees vs weight p<0.001; vs height p<0.001; vs BMI p = 0.012). In univariate analyses, shorter height, lower weight and lower BMI were all significantly associated with greater odds of narrow angle. The crude association between height and narrow angle was largely attributable to a stronger association with age and sex. Lower BMI and weight remained significantly associated with narrow angle after adjustment for height, age, sex, axial ocular biometric measures and education. In analyses stratified by sex, the association between BMI and narrow angle was only observed in women. Conclusion Lower BMI and weight were associated with significantly greater odds of narrow angle after adjusting for age, education, axial ocular biometric measures and height. The odds of narrow angle increased 7% per 1 unit decrease in BMI. This association was most evident in women. PMID:24707840

  5. Cavity mode-width spectroscopy with widely tunable ultra narrow laser.

    PubMed

    Cygan, Agata; Lisak, Daniel; Morzyński, Piotr; Bober, Marcin; Zawada, Michał; Pazderski, Eugeniusz; Ciuryło, Roman

    2013-12-02

    We explore a cavity-enhanced spectroscopic technique based on determination of the absorbtion coefficient from direct measurement of spectral width of the mode of the optical cavity filled with absorbing medium. This technique called here the cavity mode-width spectroscopy (CMWS) is complementary to the cavity ring-down spectroscopy (CRDS). While both these techniques use information on interaction time of the light with the cavity to determine absorption coefficient, the CMWS does not require to measure very fast signals at high absorption conditions. Instead the CMWS method require a very narrow line width laser with precise frequency control. As an example a spectral line shape of P7 Q6 O₂ line from the B-band was measured with use of an ultra narrow laser system based on two phase-locked external cavity diode lasers (ECDL) having tunability of ± 20 GHz at wavelength range of 687 to 693 nm.

  6. On-line registration of femtosecond time intervals based on polarization properties of femtosecond stimulated photon echo generated on exciton states

    NASA Astrophysics Data System (ADS)

    Bakhodurov, A. U.; Vashourin, N. S.; Vinogradov, E. A.; Gazizov, K. Sh.; Kompanets, V. O.; Popov, I. I.; Putilin, S. E.; Chekalin, S. V.

    2017-10-01

    This paper reflects the results of the research on the character of the dependence of the non-Faraday rotation of the femtosecond stimulated photon echo polarization plane on the time interval between the second and third exciting pulses, discretely varying from 180 to 900 fs in increments 180 fs. The time interval between the first and second pulses was equal to zero. The echo signal was formed at room temperature on exciton states localized on the surface defects of a thin three-layer textured ZnO/Si(P)/Si(B) film in the presence of a homogeneous magnetic field of 0.25 mT applied longitudinally to the optical excitation axis. The qualitative coincidence of the investigated dependence with the theoretical prediction of the investigated effect for gaseous medium is shown.

  7. Ultra-thin narrow-band, complementary narrow-band, and dual-band metamaterial absorbers for applications in the THz regime

    NASA Astrophysics Data System (ADS)

    Astorino, Maria Denise; Frezza, Fabrizio; Tedeschi, Nicola

    2017-02-01

    In this paper, ultra-thin narrow-band, complementary narrow-band, and dual-band metamaterial absorbers (MMAs), exploiting the same electric ring resonator configuration, are investigated at normal and oblique incidence for both transverse electric (TE) and transverse magnetic (TM) polarizations, and with different physical properties in the THz regime. In the analysis of the ultra-thin narrow-band MMA, the limit of applicability of the transmission line model has been overcome with the introduction of a capacitance which considers the z component of the electric field. These absorbing structures have shown a wide angular response and a polarization-insensitive behavior due to the introduction of a conducting ground plane and to the four-fold rotational symmetry of the resonant elements around the propagation axis. We have adopted a retrieval procedure to extract the effective electromagnetic parameters of the proposed MMAs and we have compared the simulated and analytical results through the interference theory.

  8. Estimating the Time Interval Between Exposure to the World Trade Center Disaster and Incident Diagnoses of Obstructive Airway Disease

    PubMed Central

    Glaser, Michelle S.; Webber, Mayris P.; Zeig-Owens, Rachel; Weakley, Jessica; Liu, Xiaoxue; Ye, Fen; Cohen, Hillel W.; Aldrich, Thomas K.; Kelly, Kerry J.; Nolan, Anna; Weiden, Michael D.; Prezant, David J.; Hall, Charles B.

    2014-01-01

    Respiratory disorders are associated with occupational and environmental exposures. The latency period between exposure and disease onset remains uncertain. The World Trade Center (WTC) disaster presents a unique opportunity to describe the latency period for obstructive airway disease (OAD) diagnoses. This prospective cohort study of New York City firefighters compared the timing and incidence of physician-diagnosed OAD relative to WTC exposure. Exposure was categorized by WTC arrival time as high (on the morning of September 11, 2001), moderate (after noon on September 11, 2001, or on September 12, 2001), or low (during September 13–24, 2001). We modeled relative rates and 95% confidence intervals of OAD incidence by exposure over the first 5 years after September 11, 2001, estimating the times of change in the relative rate with change point models. We observed a change point at 15 months after September 11, 2001. Before 15 months, the relative rate for the high- versus low-exposure group was 3.96 (95% confidence interval: 2.51, 6.26) and thereafter, it was 1.76 (95% confidence interval: 1.26, 2.46). Incident OAD was associated with WTC exposure for at least 5 years after September 11, 2001. There were higher rates of new-onset OAD among the high-exposure group during the first 15 months and, to a lesser extent, throughout follow-up. This difference in relative rate by exposure occurred despite full and free access to health care for all WTC-exposed firefighters, demonstrating the persistence of WTC-associated OAD risk. PMID:24980522

  9. Statistical regularities in the return intervals of volatility

    NASA Astrophysics Data System (ADS)

    Wang, F.; Weber, P.; Yamasaki, K.; Havlin, S.; Stanley, H. E.

    2007-01-01

    We discuss recent results concerning statistical regularities in the return intervals of volatility in financial markets. In particular, we show how the analysis of volatility return intervals, defined as the time between two volatilities larger than a given threshold, can help to get a better understanding of the behavior of financial time series. We find scaling in the distribution of return intervals for thresholds ranging over a factor of 25, from 0.6 to 15 standard deviations, and also for various time windows from one minute up to 390 min (an entire trading day). Moreover, these results are universal for different stocks, commodities, interest rates as well as currencies. We also analyze the memory in the return intervals which relates to the memory in the volatility and find two scaling regimes, ℓ<ℓ* with α1=0.64±0.02 and ℓ> ℓ* with α2=0.92±0.04; these exponent values are similar to results of Liu et al. for the volatility. As an application, we use the scaling and memory properties of the return intervals to suggest a possibly useful method for estimating risk.

  10. Taylor dispersion of colloidal particles in narrow channels

    NASA Astrophysics Data System (ADS)

    Sané, Jimaan; Padding, Johan T.; Louis, Ard A.

    2015-09-01

    We use a mesoscopic particle-based simulation technique to study the classic convection-diffusion problem of Taylor dispersion for colloidal discs in confined flow. When the disc diameter becomes non-negligible compared to the diameter of the pipe, there are important corrections to the original Taylor picture. For example, the colloids can flow more rapidly than the underlying fluid, and their Taylor dispersion coefficient is decreased. For narrow pipes, there are also further hydrodynamic wall effects. The long-time tails in the velocity autocorrelation functions are altered by the Poiseuille flow.

  11. Ultra-narrow EIA spectra of 85Rb atom in a degenerate Zeeman multiplet system

    NASA Astrophysics Data System (ADS)

    Rehman, Hafeez Ur; Qureshi, Muhammad Mohsin; Noh, Heung-Ryoul; Kim, Jin-Tae

    2015-05-01

    Ultra-narrow EIA spectral features of thermal 85Rb atom with respect to coupling Rabi frequencies in a degenerate Zeeman multiplet system have been unraveled in the cases of same (σ+ -σ+ , π ∥ π) and orthogonal (σ+ -σ- , π ⊥ π)polarization configurations. The EIA signals with subnatural linewidth of ~ 100 kHz even in the cases of same circular and linear polarizations of coupling and probe laser have been obtained for the first time theoretically and experimentally. In weak coupling power limit of orthogonal polarization configurations, time-dependent transfer of coherence plays major role in the splitting of the EIA spectra while in strong coupling power, Mollow triplet-like mechanism due to strong power bring into broad split feature. The experimental ultra-narrow EIA features using one laser combined with an AOM match well with simulated spectra obtained by using generalized time-dependent optical Bloch equations.

  12. Consequences of narrow cyclotron emission from Hercules X-1

    NASA Technical Reports Server (NTRS)

    Weaver, R. P.

    1978-01-01

    The implications of the recent observations of a narrow cyclotron line in the hard X-ray spectrum of Hercules X-1 are studied. A Monte Carlo code is used to simulate the X-ray transfer of an intrinsically narrow feature at approximately 56 keV through an opaque, cold magnetospheric shell. The results of this study indicate that if a narrow line can be emitted by the source region, then only about 10% of the photons remain in a narrow feature after scattering through the shell. The remaining photons are scattered into a broad feature (FWHM approximately 30 keV) that peaks near 20 keV. Thus, these calculations indicate that the intrinsic source luminosity of the cyclotron line is at least an order of magnitude greater than the observed luminosity.

  13. [Age- and sex-specific reference intervals for 10 health examination items: mega-data from a Japanese Health Service Association].

    PubMed

    Suka, Machi; Yoshida, Katsumi; Kawai, Tadashi; Aoki, Yoshikazu; Yamane, Noriyuki; Yamauchi, Kuniaki

    2005-07-01

    To determine age- and sex-specific reference intervals for 10 health examination items in Japanese adults. Health examination data were accumulated from 24 different prefectural health service associations affiliated with the Japan Association of Health Service. Those who were non-smokers, drank less than 7 days/week, and had a body mass index of 18.5-24.9kg/m2 were sampled as a reference population (n = 737,538; 224,947 men and 512,591 women). After classified by age and sex, reference intervals for 10 health examination items (systolic blood pressure, diastolic blood pressure, total cholesterol, triglyceride, glucose, uric acid, AST, ALT, gamma-GT, and hemoglobin) were estimated using the parametric and nonparametric methods. In every item except for hemoglobin, men had higher reference intervals than women. Systolic blood pressure, total cholesterol, and glucose showed an upward trend in values with increasing age. Hemoglobin showed a downward trend in values with increasing age. Triglyceride, ALT, and gamma-GT reached a peak in middle age. Overall, parametric estimates showed narrower reference intervals than non-parametric estimates. Reference intervals vary with age and sex. Age- and sex-specific reference intervals may contribute to better assessment of health examination data.

  14. Optic for an endoscope/borescope having high resolution and narrow field of view

    DOEpatents

    Stone, Gary F.; Trebes, James E.

    2003-10-28

    An optic having optimized high spatial resolution, minimal nonlinear magnification distortion while at the same time having a limited chromatic focal shift or chromatic aberrations. The optic located at the distal end of an endoscopic inspection tool permits a high resolution, narrow field of view image for medical diagnostic applications, compared to conventional optics for endoscopic instruments which provide a wide field of view, low resolution image. The image coverage is over a narrow (<20 degrees) field of view with very low optical distortion (<5% pin cushion or barrel distortion. The optic is also optimized for best color correction as well as to aid medical diagnostics.

  15. A novel implementation of homodyne time interval analysis method for primary vibration calibration

    NASA Astrophysics Data System (ADS)

    Sun, Qiao; Zhou, Ling; Cai, Chenguang; Hu, Hongbo

    2011-12-01

    In this paper, the shortcomings and their causes of the conventional homodyne time interval analysis (TIA) method is described with respect to its software algorithm and hardware implementation, based on which a simplified TIA method is proposed with the help of virtual instrument technology. Equipped with an ordinary Michelson interferometer and dual channel synchronous data acquisition card, the primary vibration calibration system using the simplified method can perform measurements of complex sensitivity of accelerometers accurately, meeting the uncertainty requirements laid down in pertaining ISO standard. The validity and accuracy of the simplified TIA method is verified by simulation and comparison experiments with its performance analyzed. This simplified method is recommended to apply in national metrology institute of developing countries and industrial primary vibration calibration labs for its simplified algorithm and low requirements on hardware.

  16. Real-time hydraulic interval state estimation for water transport networks: a case study

    NASA Astrophysics Data System (ADS)

    Vrachimis, Stelios G.; Eliades, Demetrios G.; Polycarpou, Marios M.

    2018-03-01

    Hydraulic state estimation in water distribution networks is the task of estimating water flows and pressures in the pipes and nodes of the network based on some sensor measurements. This requires a model of the network as well as knowledge of demand outflow and tank water levels. Due to modeling and measurement uncertainty, standard state estimation may result in inaccurate hydraulic estimates without any measure of the estimation error. This paper describes a methodology for generating hydraulic state bounding estimates based on interval bounds on the parametric and measurement uncertainties. The estimation error bounds provided by this method can be applied to determine the existence of unaccounted-for water in water distribution networks. As a case study, the method is applied to a modified transport network in Cyprus, using actual data in real time.

  17. SUPRATHERMAL ELECTRON STRAHL WIDTHS IN THE PRESENCE OF NARROW-BAND WHISTLER WAVES IN THE SOLAR WIND

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kajdič, P.; Alexandrova, O.; Maksimovic, M.

    2016-12-20

    We perform the first statistical study of the effects of the interaction of suprathermal electrons with narrow-band whistler mode waves in the solar wind (SW). We show that this interaction does occur and that it is associated with enhanced widths of the so-called strahl component. The latter is directed along the interplanetary magnetic field away from the Sun. We do the study by comparing the strahl pitch angle widths in the SW at 1 AU in the absence of large scale discontinuities and transient structures, such as interplanetary shocks, interplanetary coronal mass ejections, stream interaction regions, etc. during times whenmore » the whistler mode waves were present and when they were absent. This is done by using the data from two Cluster instruments: Spatio Temporal Analysis of Field Fluctuations experiment (STAFF) data in the frequency range between ∼0.1 and ∼200 Hz were used for determining the wave properties and Plasma Electron And Current Experiment (PEACE) data sets at 12 central energies between ∼57 eV (equivalent to ∼10 typical electron thermal energies in the SW, E{sub T}) and ∼676 eV (∼113 E{sub T}) for pitch angle measurements. Statistical analysis shows that, during the intervals with the whistler waves, the strahl component on average exhibits pitch angle widths between 2° and 12° larger than during the intervals when these waves are not present. The largest difference is obtained for the electron central energy of ∼344 eV (∼57 ET).« less

  18. The Structure of A Pacific Narrow Cold Frontal Rainband

    NASA Technical Reports Server (NTRS)

    Jorgensen, David P.; Pu, Zhaoxia; Persson, Ola; Tao, Wei-Kuo; Starr, David OC. (Technical Monitor)

    2002-01-01

    A NOAA P-3 instrumented aircraft observed an intense, fast-moving narrow cold frontal Farmhand as it approached the Pacific Northwest coast on 19 February 2001 during the Pacific Coastal Jets Experiment. Pseudo-dual-Doppler analyses performed on the airborne Doppler radar data while the frontal system was well offshore indicated that a narrow ribbon of very high radar reflectively convective cores characterized the Farmhand at low levels with echo tops to approximately 4-5 km. The NCFR exhibited gaps in its narrow ribbon of high reflectively, probably as a result of hydrodynamic instability all no its advancing cold pool leading edge. In contrast to some earlier studies of cold frontal rainbands, density current theory described well the motion of the overall front. The character of the updraft structure associated with the heavy rainfall at its leading edge varied across the gap region. The vertical shear of the cross-frontal low-level ambient flow exerted a strong influence on the updraft character, consistent with theoretical arguments developed for squall lines describing the balance of vorticity at the leading edge. In short regions south of the gaps the vertical wind shear was strongest with the updrafts and rain shafts more intense, narrower, and more erect or even downshear tilted. North of the gaps the wind shear weakened with less intense Dihedrals which tilted upshear with a broader band of rainfall. Simulations using a nonhydrostatic mesoscale nested grid model are used to investigate the gap regions, particularly the balance of cold pool induced to pre-frontal ambient shears at the leading edge. Observations confirm the model results that the updraft character depends on the balance of vorticity at the leading edge. Downshear-tilted updrafts imply that convection south of the gap regions would weaken with time relative to the frontal segments north of the gaps since inflow air would be affected by passage through the heavy rain region before ascent

  19. High-intensity interval training: Modulating interval duration in overweight/obese men.

    PubMed

    Smith-Ryan, Abbie E; Melvin, Malia N; Wingfield, Hailee L

    2015-05-01

    High-intensity interval training (HIIT) is a time-efficient strategy shown to induce various cardiovascular and metabolic adaptations. Little is known about the optimal tolerable combination of intensity and volume necessary for adaptations, especially in clinical populations. In a randomized controlled pilot design, we evaluated the effects of two types of interval training protocols, varying in intensity and interval duration, on clinical outcomes in overweight/obese men. Twenty-five men [body mass index (BMI) > 25 kg · m(2)] completed baseline body composition measures: fat mass (FM), lean mass (LM) and percent body fat (%BF) and fasting blood glucose, lipids and insulin (IN). A graded exercise cycling test was completed for peak oxygen consumption (VO2peak) and power output (PO). Participants were randomly assigned to high-intensity short interval (1MIN-HIIT), high-intensity interval (2MIN-HIIT) or control groups. 1MIN-HIIT and 2MIN-HIIT completed 3 weeks of cycling interval training, 3 days/week, consisting of either 10 × 1 min bouts at 90% PO with 1 min rests (1MIN-HIIT) or 5 × 2 min bouts with 1 min rests at undulating intensities (80%-100%) (2MIN-HIIT). There were no significant training effects on FM (Δ1.06 ± 1.25 kg) or %BF (Δ1.13% ± 1.88%), compared to CON. Increases in LM were not significant but increased by 1.7 kg and 2.1 kg for 1MIN and 2MIN-HIIT groups, respectively. Increases in VO2peak were also not significant for 1MIN (3.4 ml·kg(-1) · min(-1)) or 2MIN groups (2.7 ml · kg(-1) · min(-1)). IN sensitivity (HOMA-IR) improved for both training groups (Δ-2.78 ± 3.48 units; p < 0.05) compared to CON. HIIT may be an effective short-term strategy to improve cardiorespiratory fitness and IN sensitivity in overweight males.

  20. High-intensity interval training: Modulating interval duration in overweight/obese men

    PubMed Central

    Smith-Ryan, Abbie E.; Melvin, Malia N.; Wingfield, Hailee L.

    2015-01-01

    Introduction High-intensity interval training (HIIT) is a time-efficient strategy shown to induce various cardiovascular and metabolic adaptations. Little is known about the optimal tolerable combination of intensity and volume necessary for adaptations, especially in clinical populations. Objectives In a randomized controlled pilot design, we evaluated the effects of two types of interval training protocols, varying in intensity and interval duration, on clinical outcomes in overweight/obese men. Methods Twenty-five men [body mass index (BMI) > 25 kg·m2] completed baseline body composition measures: fat mass (FM), lean mass (LM) and percent body fat (%BF) and fasting blood glucose, lipids and insulin (IN). A graded exercise cycling test was completed for peak oxygen consumption (VO2peak) and power output (PO). Participants were randomly assigned to high-intensity short interval (1MIN-HIIT), high-intensity interval (2MIN-HIIT) or control groups. 1MIN-HIIT and 2MIN-HIIT completed 3 weeks of cycling interval training, 3 days/week, consisting of either 10 × 1 min bouts at 90% PO with 1 min rests (1MIN-HIIT) or 5 × 2 min bouts with 1 min rests at undulating intensities (80%–100%) (2MIN-HIIT). Results There were no significant training effects on FM (Δ1.06 ± 1.25 kg) or %BF (Δ1.13% ± 1.88%), compared to CON. Increases in LM were not significant but increased by 1.7 kg and 2.1 kg for 1MIN and 2MIN-HIIT groups, respectively. Increases in VO2peak were also not significant for 1MIN (3.4 ml·kg−1·min−1) or 2MIN groups (2.7 ml·kg−1·min−1). IN sensitivity (HOMA-IR) improved for both training groups (Δ −2.78 ± 3.48 units; p < 0.05) compared to CON. Conclusion HIIT may be an effective short-term strategy to improve cardiorespiratory fitness and IN sensitivity in overweight males. PMID:25913937

  1. Military Applicability of Interval Training for Health and Performance.

    PubMed

    Gibala, Martin J; Gagnon, Patrick J; Nindl, Bradley C

    2015-11-01

    Militaries from around the globe have predominantly used endurance training as their primary mode of aerobic physical conditioning, with historical emphasis placed on the long distance run. In contrast to this traditional exercise approach to training, interval training is characterized by brief, intermittent bouts of intense exercise, separated by periods of lower intensity exercise or rest for recovery. Although hardly a novel concept, research over the past decade has shed new light on the potency of interval training to elicit physiological adaptations in a time-efficient manner. This work has largely focused on the benefits of low-volume interval training, which involves a relatively small total amount of exercise, as compared with the traditional high-volume approach to training historically favored by militaries. Studies that have directly compared interval and moderate-intensity continuous training have shown similar improvements in cardiorespiratory fitness and the capacity for aerobic energy metabolism, despite large differences in total exercise and training time commitment. Interval training can also be applied in a calisthenics manner to improve cardiorespiratory fitness and strength, and this approach could easily be incorporated into a military conditioning environment. Although interval training can elicit physiological changes in men and women, the potential for sex-specific adaptations in the adaptive response to interval training warrants further investigation. Additional work is needed to clarify adaptations occurring over the longer term; however, interval training deserves consideration from a military applicability standpoint as a time-efficient training strategy to enhance soldier health and performance. There is value for military leaders in identifying strategies that reduce the time required for exercise, but nonetheless provide an effective training stimulus.

  2. Effect of Time Interval Between Tumescent Local Anesthesia Infiltration and Start of Surgery on Operative Field Visibility in Hand Surgery Without Tourniquet.

    PubMed

    Bashir, Muhammad Mustehsan; Qayyum, Rehan; Saleem, Muhammad Hammad; Siddique, Kashif; Khan, Farid Ahmad

    2015-08-01

    To determine the optimal time interval between tumescent local anesthesia infiltration and the start of hand surgery without a tourniquet for improved operative field visibility. Patients aged 16 to 60 years who needed contracture release and tendon repair in the hand were enrolled from the outpatient clinic. Patients were randomized to 10-, 15-, or 25-minute intervals between tumescent anesthetic solution infiltration (0.18% lidocaine and 1:221,000 epinephrine) and the start of surgery. The end point of tumescence anesthetic infiltration was pale and firm skin. The surgical team was blinded to the time of anesthetic infiltration. At the completion of the procedure, the surgeon and the first assistant rated the operative field visibility as excellent, fair, or poor. We used logistic regression models without and with adjustment for confounding variables. Of the 75 patients enrolled in the study, 59 (79%) were males, 7 were randomized to 10-minute time intervals (further randomization was stopped after interim analysis found consistently poor operative field visibility), and 34 were randomized to the each of the 15- and 25-minute groups. Patients who were randomized to the 25-minute delay group had 29 times higher odds of having an excellent operative visual field than those randomized to the 15-minute delay group. After adjusting for age, sex, amount of tumescent solution infiltration, and duration of operation, the odds ratio remained highly significant. We found that an interval of 25 minutes provides vastly superior operative field visibility; 10-minute delay had the poorest results. Therapeutic I. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  3. Retention of sequential drug discriminations under fixed-interval schedules for long time periods without training.

    PubMed

    Li, Mi; McMillan, Donald E

    2003-08-22

    The experiments showed that sequential drug discriminations can be learned and retained under a fixed-interval (FI) schedule for more than 18 months without additional training under a complex three-choice procedure. Pigeons were trained to discriminate among 5 mg/kg pentobarbital, 2 mg/kg D-amphetamine, and saline. After responding stabilized, dose-response curves were determined for other drugs. Subsequently, pentobarbital was replaced with 5 mg/kg morphine as a training drug, and D-amphetamine was replaced with 30 mg/kg caffeine. After the pigeons learned these new discriminations, dose-response curves were redetermined. Initially, chlordiazepoxide substituted for pentobarbital, cocaine substituted for D-amphetamine, and nicotine partially substituted for D-amphetamine. Morphine, Delta9-tetrahydrocannabinol, and caffeine did not substitute for either drug. After retraining with morphine and caffeine, responding occurred on the pentobarbital/morphine key after pentobarbital, chlordiazepoxide and morphine and on the D-amphetamine/caffeine key after D-amphetamine, cocaine and caffeine. After nicotine and Delta9-tetrahyrdocannabinol, responding occurred on the saline key. These data show that drug discriminations learned under fixed-interval schedules are retained for long time periods, even when discrimination training with other drugs occurs during the retention period.

  4. QSO Narrow [OIII] Line Width and Host Galaxy Luminosity

    NASA Astrophysics Data System (ADS)

    Bonning, E. W.; Shields, G. A.; Salviander, S.

    2004-05-01

    Established correlations between galaxy bulge luminosity L, black hole mass MBH, and stellar velocity dispersion sigma in galaxies suggest a close relationship between the growth of supermassive black holes and their host galaxies. Measurements of the MBH - sigma relationship as a function of cosmic time may shed light on the origin of this relationship. One approach is to derive MBH and sigma from the widths of QSO broad and narrow lines, respectively (Shields et al. 2003, ApJ, 583, 124; Nelson 2000, ApJ, 544, L91). We investigate the utility of using the velocity of the narrow line emitting gas as a surrogate for stellar velocity dispersion in QSOs by examining host magnitudes and [OIII] line widths for low redshift QSOs. For our limited range of L, the increase in sigma with L predicted by the Faber-Jackson relation is substantially obscured by scatter. However, sigma([O III]) is consistent in the mean with host galaxy luminosity. EWB is a NASA GSRP fellow. GAS and SS are supported under Texas Advanced Research Program grant 003658-0177-2001 and NSF grant AST-0098594.

  5. Cox model with interval-censored covariate in cohort studies.

    PubMed

    Ahn, Soohyun; Lim, Johan; Paik, Myunghee Cho; Sacco, Ralph L; Elkind, Mitchell S

    2018-05-18

    In cohort studies the outcome is often time to a particular event, and subjects are followed at regular intervals. Periodic visits may also monitor a secondary irreversible event influencing the event of primary interest, and a significant proportion of subjects develop the secondary event over the period of follow-up. The status of the secondary event serves as a time-varying covariate, but is recorded only at the times of the scheduled visits, generating incomplete time-varying covariates. While information on a typical time-varying covariate is missing for entire follow-up period except the visiting times, the status of the secondary event are unavailable only between visits where the status has changed, thus interval-censored. One may view interval-censored covariate of the secondary event status as missing time-varying covariates, yet missingness is partial since partial information is provided throughout the follow-up period. Current practice of using the latest observed status produces biased estimators, and the existing missing covariate techniques cannot accommodate the special feature of missingness due to interval censoring. To handle interval-censored covariates in the Cox proportional hazards model, we propose an available-data estimator, a doubly robust-type estimator as well as the maximum likelihood estimator via EM algorithm and present their asymptotic properties. We also present practical approaches that are valid. We demonstrate the proposed methods using our motivating example from the Northern Manhattan Study. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Design, Construction, Demonstration and Delivery of an Automated Narrow Gap Welding System.

    DTIC Science & Technology

    1982-06-29

    DESIGN, CONSTRUCTION, DEMONSTRATION AND DELIVERY OF WE DA4I &NARROW GAP CONTRACT NO. NOOGOO-81-C-E923 TO DAVID TAYLOR NAVAL RESEARCH AND DEVELOPMENT...the automated * Narrow Gap welding process, is the narrow (3/8 - inch), square-butt joint *design. This narrow joint greatly reduces the volume of weld...AD-i45 495 DESIGN CONSTRUCTION DEMONSTRATION AiND DELIVERY OF RN 1/j AUrOMATED NARROW GAP WELDING SYSTEMI() CRC AUTOMATIC WELDING CO HOUSTON TX 29

  7. Ongoing behavior predicts perceptual report of interval duration

    PubMed Central

    Gouvêa, Thiago S.; Monteiro, Tiago; Soares, Sofia; Atallah, Bassam V.; Paton, Joseph J.

    2014-01-01

    The ability to estimate the passage of time is essential for adaptive behavior in complex environments. Yet, it is not known how the brain encodes time over the durations necessary to explain animal behavior. Under temporally structured reinforcement schedules, animals tend to develop temporally structured behavior, and interval timing has been suggested to be accomplished by learning sequences of behavioral states. If this is true, trial to trial fluctuations in behavioral sequences should be predictive of fluctuations in time estimation. We trained rodents in an duration categorization task while continuously monitoring their behavior with a high speed camera. Animals developed highly reproducible behavioral sequences during the interval being timed. Moreover, those sequences were often predictive of perceptual report from early in the trial, providing support to the idea that animals may use learned behavioral patterns to estimate the duration of time intervals. To better resolve the issue, we propose that continuous and simultaneous behavioral and neural monitoring will enable identification of neural activity related to time perception that is not explained by ongoing behavior. PMID:24672473

  8. Bayesian Face Recognition and Perceptual Narrowing in Face-Space

    PubMed Central

    Balas, Benjamin

    2012-01-01

    During the first year of life, infants’ face recognition abilities are subject to “perceptual narrowing,” the end result of which is that observers lose the ability to distinguish previously discriminable faces (e.g. other-race faces) from one another. Perceptual narrowing has been reported for faces of different species and different races, in developing humans and primates. Though the phenomenon is highly robust and replicable, there have been few efforts to model the emergence of perceptual narrowing as a function of the accumulation of experience with faces during infancy. The goal of the current study is to examine how perceptual narrowing might manifest as statistical estimation in “face space,” a geometric framework for describing face recognition that has been successfully applied to adult face perception. Here, I use a computer vision algorithm for Bayesian face recognition to study how the acquisition of experience in face space and the presence of race categories affect performance for own and other-race faces. Perceptual narrowing follows from the establishment of distinct race categories, suggesting that the acquisition of category boundaries for race is a key computational mechanism in developing face expertise. PMID:22709406

  9. Intermittent Drug Dosing Intervals Guided by the Operational Multiple Dosing Half Lives for Predictable Plasma Accumulation and Fluctuation

    PubMed Central

    Grover, Anita; Benet, Leslie Z.

    2013-01-01

    Intermittent drug dosing intervals are usually initially guided by the terminal pharmacokinetic half life and are dependent on drug formulation. For chronic multiple dosing and for extended release dosage forms, the terminal half life often does not predict the plasma drug accumulation or fluctuation observed. We define and advance applications for the operational multiple dosing half lives for drug accumulation and fluctuation after multiple oral dosing at steady-state. Using Monte Carlo simulation, our results predict a way to maximize the operational multiple dosing half lives relative to the terminal half life by using a first-order absorption rate constant close to the terminal elimination rate constant in the design of extended release dosage forms. In this way, drugs that may be eliminated early in the development pipeline due to a relatively short half life can be formulated to be dosed at intervals three times the terminal half life, maximizing compliance, while maintaining tight plasma concentration accumulation and fluctuation ranges. We also present situations in which the operational multiple dosing half lives will be especially relevant in the determination of dosing intervals, including for drugs that follow a direct PKPD model and have a narrow therapeutic index, as the rate of concentration decrease after chronic multiple dosing (that is not the terminal half life) can be determined via simulation. These principles are illustrated with case studies on valproic acid, diazepam, and anti-hypertensives. PMID:21499748

  10. Parametric Dynamic Load Prediction of a Narrow Gauge Rocket Sled

    DTIC Science & Technology

    2006-12-01

    Monorail λ Compared to Sled Tests.......................................................... 11 Figure 2.1 Application of Vertical λ to a Narrow Gauge sled...Three distinct sled configurations are used: monorail , dual rail wide gauge, and dual rail narrow gauge. Of the three, the narrow gauge...weight and the resulting value was termed λ. Monorail λ factor loading was first documented by Mixon (1971) where a few measured data points were

  11. Effects of short-time preheating on ice growth in antifreeze polypeptides solutions in a narrow space

    NASA Astrophysics Data System (ADS)

    Miyamoto, T.; Nishi, N.; Waku, T.; Tanaka, N.; Hagiwara, Y.

    2018-03-01

    We conducted experiments on the unidirectional freezing of solutions of winter flounder antifreeze protein or of a polypeptide which was based on twelve amino-acid residues of this protein. The temperature in the solutions and ice was measured with a small thermocouple. The interface temperature was defined as the temperature at the tip of the serrated or pectinate interface. The interface temperature of these solutions was lower than that of pure water. To vary this supercooling activity of these solutes, we preheated the solutions and cooled them before conducting identical experiments. It was found that short-time preheating caused further decreases in the interface temperature and interface velocities. Furthermore, the inclined interfaces and the narrow liquid regions inside the ice area became wider. To investigate the reasons for these changes, we measured aggregates of the solutes in the solutions. These aggregates were found to become larger as a result of preheating. Thus, it can be concluded that these large aggregates attenuated the ice growth by their interaction with ice. Finally, we carried out similar measurements by using pH-adjusted solutions of the protein to produce aggregates without preheating, and obtained similar supercooling enhancement by the aggregates. Thus, the effects of thermal denaturation on the supercooling were not significant in the preheating.

  12. Observer Error when Measuring Safety-Related Behavior: Momentary Time Sampling versus Whole-Interval Recording

    ERIC Educational Resources Information Center

    Taylor, Matthew A.; Skourides, Andreas; Alvero, Alicia M.

    2012-01-01

    Interval recording procedures are used by persons who collect data through observation to estimate the cumulative occurrence and nonoccurrence of behavior/events. Although interval recording procedures can increase the efficiency of observational data collection, they can also induce error from the observer. In the present study, 50 observers were…

  13. Narrowing beam-walking is a clinically feasible approach for assessing balance ability in lower-limb prosthesis users.

    PubMed

    Sawers, Andrew; Hafner, Brian J

    2018-05-08

    Challenging clinical balance tests are needed to expose balance deficits in lower-limb prost-hesis users. This study examined whether narrowing beam-walking could overcome conceptual and practical limitations identified in fixed-width beam-walking. Cross-sectional. Unilateral lower-limb prosthesis users. Participants walked 10 times along a low, narrowing beam. Performance was quantified using the normalized distance walked. Heuristic rules were applied to determine whether the narrowing beam task was "too easy," "too hard," or "appropriately challenging" for each participant. Linear regression and Bland-Altman plots were used to determine whether combinations of the first 5 trials could predict participants' stable beam-walking performance. Forty unilateral lower-limb prosthesis users participated. Narrowing beam-walking was appropriately challenging for 98% of participants. Performance stabilized for 93% of participants within 5 trials, while 62% were stable across all trials. The mean of trials 3-5 accurately predicted stable performance. A clinical narrowing beam-walking test is likely to challenge a range of lower-limb prosthesis users, have minimal administrative burden, and exhibit no floor or ceiling effects. Narrowing beam-walking is therefore a clinically viable method to evaluate lower-limb prosthesis users' balance ability, but requires psychometric testing before it is used to assess fall risk.

  14. A study of intensity, fatigue and precision in two specific interval trainings in young tennis players: high-intensity interval training versus intermittent interval training

    PubMed Central

    Suárez Rodríguez, David; del Valle Soto, Miguel

    2017-01-01

    Background The aim of this study is to find the differences between two specific interval exercises. We begin with the hypothesis that the use of microintervals of work and rest allow for greater intensity of play and a reduction in fatigue. Methods Thirteen competition-level male tennis players took part in two interval training exercises comprising nine 2 min series, which consisted of hitting the ball with cross-court forehand and backhand shots, behind the service box. One was a high-intensity interval training (HIIT), made up of periods of continuous work lasting 2 min, and the other was intermittent interval training (IIT), this time with intermittent 2 min intervals, alternating periods of work with rest periods. Average heart rate (HR) and lactate levels were registered in order to observe the physiological intensity of the two exercises, along with the Borg Scale results for perceived exertion and the number of shots and errors in order to determine the intensity achieved and the degree of fatigue throughout the exercise. Results There were no significant differences in the average heart rate, lactate or the Borg Scale. Significant differences were registered, on the other hand, with a greater number of shots in the first two HIIT series (series 1 p>0.009; series 2 p>0.056), but not in the third. The number of errors was significantly lower in all the IIT series (series 1 p<0.035; series 2 p<0.010; series 3 p<0.001). Conclusion Our study suggests that high-intensity intermittent training allows for greater intensity of play in relation to the real time spent on the exercise, reduced fatigue levels and the maintaining of greater precision in specific tennis-related exercises. PMID:29021912

  15. A Variable Oscillator Underlies the Measurement of Time Intervals in the Rostral Medial Prefrontal Cortex during Classical Eyeblink Conditioning in Rabbits.

    PubMed

    Caro-Martín, C Rocío; Leal-Campanario, Rocío; Sánchez-Campusano, Raudel; Delgado-García, José M; Gruart, Agnès

    2015-11-04

    We were interested in determining whether rostral medial prefrontal cortex (rmPFC) neurons participate in the measurement of conditioned stimulus-unconditioned stimulus (CS-US) time intervals during classical eyeblink conditioning. Rabbits were conditioned with a delay paradigm consisting of a tone as CS. The CS started 50, 250, 500, 1000, or 2000 ms before and coterminated with an air puff (100 ms) directed at the cornea as the US. Eyelid movements were recorded with the magnetic search coil technique and the EMG activity of the orbicularis oculi muscle. Firing activities of rmPFC neurons were recorded across conditioning sessions. Reflex and conditioned eyelid responses presented a dominant oscillatory frequency of ≈12 Hz. The firing rate of each recorded neuron presented a single peak of activity with a frequency dependent on the CS-US interval (i.e., ≈12 Hz for 250 ms, ≈6 Hz for 500 ms, and≈3 Hz for 1000 ms). Interestingly, rmPFC neurons presented their dominant firing peaks at three precise times evenly distributed with respect to CS start and also depending on the duration of the CS-US interval (only for intervals of 250, 500, and 1000 ms). No significant neural responses were recorded at very short (50 ms) or long (2000 ms) CS-US intervals. rmPFC neurons seem not to encode the oscillatory properties characterizing conditioned eyelid responses in rabbits, but are probably involved in the determination of CS-US intervals of an intermediate range (250-1000 ms). We propose that a variable oscillator underlies the generation of working memories in rabbits. The way in which brains generate working memories (those used for the transient processing and storage of newly acquired information) is still an intriguing question. Here, we report that the firing activities of neurons located in the rostromedial prefrontal cortex recorded in alert behaving rabbits are controlled by a dynamic oscillator. This oscillator generated firing frequencies in a variable band

  16. Confirmation of Romer's Gap as a low oxygen interval constraining the timing of initial arthropod and vertebrate terrestrialization

    PubMed Central

    Ward, Peter; Labandeira, Conrad; Laurin, Michel; Berner, Robert A.

    2006-01-01

    The first terrestrialization of species that evolved from previously aquatic taxa was a seminal event in evolutionary history. For vertebrates, one of the most important terrestrialized groups, this event was interrupted by a time interval known as Romer's Gap, for which, until recently, few fossils were known. Here, we argue that geochronologic range data of terrestrial arthropods show a pattern similar to that of vertebrates. Thus, Romer's Gap is real, occupied an interval from 360 million years before present (MYBP) to 345 MYBP, and occurred when environmental conditions were unfavorable for air-breathing, terrestrial animals. These model results suggest that atmospheric oxygen levels were the major driver of successful terrestrialization, and a low-oxygen interval accounts for Romer's Gap. Results also show that terrestrialization among members of arthropod and vertebrate clades occurred in two distinct phases. The first phase was a 65-million-year (My) interval from 425 to 360 MYBP, representing an earlier, prolonged event of complete arthropod terrestrialization of smaller-sized forms (425–385 MYBP) and a subsequent, modest, and briefer event of incipient terrestrialization of larger-sized, aquatic vertebrates (385–360 MYBP). The second phase began at 345 MYBP, characterized by numerous new terrestrial species emerging in both major clades. The first and second terrestrialization phases bracket Romer's Gap, which represents a depauperate spectrum of major arthropod and vertebrate taxa before a major Late Paleozoic colonization of terrestrial habitats. PMID:17065318

  17. Pulse stretcher for narrow pulses

    NASA Technical Reports Server (NTRS)

    Lindsey, R. S., Jr. (Inventor)

    1974-01-01

    A pulse stretcher for narrow pulses is presented. The stretcher is composed of an analog section for processing each arriving analog pulse and a digital section with logic for providing command signals to the gates and switches in the analog section.

  18. Hematology and biochemistry reference intervals for Ontario commercial nursing pigs close to the time of weaning

    PubMed Central

    Perri, Amanda M.; O’Sullivan, Terri L.; Harding, John C.S.; Wood, R. Darren; Friendship, Robert M.

    2017-01-01

    The evaluation of pig hematology and biochemistry parameters is rarely done largely due to the costs associated with laboratory testing and labor, and the limited availability of reference intervals needed for interpretation. Within-herd and between-herd biological variation of these values also make it difficult to establish reference intervals. Regardless, baseline reference intervals are important to aid veterinarians in the interpretation of blood parameters for the diagnosis and treatment of diseased swine. The objective of this research was to provide reference intervals for hematology and biochemistry parameters of 3-week-old commercial nursing piglets in Ontario. A total of 1032 pigs lacking clinical signs of disease from 20 swine farms were sampled for hematology and iron panel evaluation, with biochemistry analysis performed on a subset of 189 randomly selected pigs. The 95% reference interval, mean, median, range, and 90% confidence intervals were calculated for each parameter. PMID:28373729

  19. Interval sampling methods and measurement error: a computer simulation.

    PubMed

    Wirth, Oliver; Slaven, James; Taylor, Matthew A

    2014-01-01

    A simulation study was conducted to provide a more thorough account of measurement error associated with interval sampling methods. A computer program simulated the application of momentary time sampling, partial-interval recording, and whole-interval recording methods on target events randomly distributed across an observation period. The simulation yielded measures of error for multiple combinations of observation period, interval duration, event duration, and cumulative event duration. The simulations were conducted up to 100 times to yield measures of error variability. Although the present simulation confirmed some previously reported characteristics of interval sampling methods, it also revealed many new findings that pertain to each method's inherent strengths and weaknesses. The analysis and resulting error tables can help guide the selection of the most appropriate sampling method for observation-based behavioral assessments. © Society for the Experimental Analysis of Behavior.

  20. Steering Dynamics of Tilting Narrow Track Vehicle with Passive Front Wheel Design

    NASA Astrophysics Data System (ADS)

    TAN, Jeffrey Too Chuan; ARAKAWA, Hiroki; SUDA, Yoshihiro

    2016-09-01

    In recent years, narrow track vehicle has been emerged as a potential candidate for the next generation of urban transportation system, which is greener and space effective. Vehicle body tilting has been a symbolic characteristic of such vehicle, with the purpose to maintain its stability with the narrow track body. However, the coordination between active steering and vehicle tilting requires considerable driving skill in order to achieve effective stability. In this work, we propose an alternative steering method with a passive front wheel that mechanically follows the vehicle body tilting. The objective of this paper is to investigate the steering dynamics of the vehicle under various design parameters of the passive front wheel. Modeling of a three-wheel tilting narrow track vehicle and multibody dynamics simulations were conducted to study the effects of two important front wheel design parameters, i.e. caster angle and trail toward the vehicle steering dynamics in steering response time, turning radius, steering stability and resiliency towards external disturbance. From the results of the simulation studies, we have verified the relationships of these two front wheel design parameters toward the vehicle steering dynamics.

  1. The Association between End-of-Life Care and the Time Interval between Provision of a Do-Not-Resuscitate Consent and Death in Cancer Patients in Korea.

    PubMed

    Baek, Sun Kyung; Chang, Hye Jung; Byun, Ja Min; Han, Jae Joon; Heo, Dae Seog

    2017-04-01

    We explored the relationship between the use of each medical intervention and the length of time between do-not-resuscitate (DNR) consent and death in Korea. A total of 295 terminal cancer patients participated in this retrospective study. Invasive interventions (e.g., cardiopulmonary resuscitation, intubation, and hemodialysis), less invasive interventions (e.g., transfusion, antibiotic use, inotropic use, and laboratory tests), and the time interval between the DNR order and death were evaluated. The subjects were divided into three groups based on the amount of time between DNR consent and death (G1, time interval ≤ 1 day; G2, time interval > 1 day to ≤ 3 days; and G3, time interval > 3 days). In general, there were fewer transfusions and laboratory tests near death. Invasive interventions tended to be implemented only in the G1 group. There was also less inotrope use and fewer laboratory tests in the G3 group than G1 and G2. Moreover, the G3 group received fewer less invasive interventions than those in G1 (odds ratio [OR], 0.16; 95% confidence interval [CI], 0.03 to 0.84; 3 days before death, and OR, 0.16; 95% CI, 0.04 to 0.59; the day before death). The frequency of less invasive interventions both 1 and 3 days before death was significantly lower for the G3 group than the G1 (p ≤ 0.001) and G2 group compared to G1 (p=0.001). Earlier attainment of DNR permission was associated with reduced use of medical intervention. Thus, physicians should discuss death with terminal cancer patients at the earliest practical time to prevent unnecessary and uncomfortable procedures and reduce health care costs.

  2. Active linewidth-narrowing of a mid-infrared quantum cascade laser without optical reference.

    PubMed

    Tombez, L; Schilt, S; Hofstetter, D; Südmeyer, T

    2013-12-01

    We report on a technique for frequency noise reduction and linewidth-narrowing of a distributed-feedback mid-IR quantum cascade laser (QCL) that does not involve any optical frequency reference. The voltage fluctuations across the QCL are sensed, amplified and fed back to the temperature of the QCL at a fast rate using a near-IR laser illuminating the top of the QCL chip. A locking bandwidth of 300 kHz and a reduction of the frequency noise power spectral density by a factor of 10 with respect to the free-running laser are achieved. From 2 MHz for the free-running QCL, the linewidth is narrowed below 700 kHz (10 ms observation time).

  3. Modeling Pharmacological Clock and Memory Patterns of Interval Timing in a Striatal Beat-Frequency Model with Realistic, Noisy Neurons

    PubMed Central

    Oprisan, Sorinel A.; Buhusi, Catalin V.

    2011-01-01

    In most species, the capability of perceiving and using the passage of time in the seconds-to-minutes range (interval timing) is not only accurate but also scalar: errors in time estimation are linearly related to the estimated duration. The ubiquity of scalar timing extends over behavioral, lesion, and pharmacological manipulations. For example, in mammals, dopaminergic drugs induce an immediate, scalar change in the perceived time (clock pattern), whereas cholinergic drugs induce a gradual, scalar change in perceived time (memory pattern). How do these properties emerge from unreliable, noisy neurons firing in the milliseconds range? Neurobiological information relative to the brain circuits involved in interval timing provide support for an striatal beat frequency (SBF) model, in which time is coded by the coincidental activation of striatal spiny neurons by cortical neural oscillators. While biologically plausible, the impracticality of perfect oscillators, or their lack thereof, questions this mechanism in a brain with noisy neurons. We explored the computational mechanisms required for the clock and memory patterns in an SBF model with biophysically realistic and noisy Morris–Lecar neurons (SBF–ML). Under the assumption that dopaminergic drugs modulate the firing frequency of cortical oscillators, and that cholinergic drugs modulate the memory representation of the criterion time, we show that our SBF–ML model can reproduce the pharmacological clock and memory patterns observed in the literature. Numerical results also indicate that parameter variability (noise) – which is ubiquitous in the form of small fluctuations in the intrinsic frequencies of neural oscillators within and between trials, and in the errors in recording/retrieving stored information related to criterion time – seems to be critical for the time-scale invariance of the clock and memory patterns. PMID:21977014

  4. An interval model updating strategy using interval response surface models

    NASA Astrophysics Data System (ADS)

    Fang, Sheng-En; Zhang, Qiu-Hu; Ren, Wei-Xin

    2015-08-01

    Stochastic model updating provides an effective way of handling uncertainties existing in real-world structures. In general, probabilistic theories, fuzzy mathematics or interval analyses are involved in the solution of inverse problems. However in practice, probability distributions or membership functions of structural parameters are often unavailable due to insufficient information of a structure. At this moment an interval model updating procedure shows its superiority in the aspect of problem simplification since only the upper and lower bounds of parameters and responses are sought. To this end, this study develops a new concept of interval response surface models for the purpose of efficiently implementing the interval model updating procedure. The frequent interval overestimation due to the use of interval arithmetic can be maximally avoided leading to accurate estimation of parameter intervals. Meanwhile, the establishment of an interval inverse problem is highly simplified, accompanied by a saving of computational costs. By this means a relatively simple and cost-efficient interval updating process can be achieved. Lastly, the feasibility and reliability of the developed method have been verified against a numerical mass-spring system and also against a set of experimentally tested steel plates.

  5. Polarization-maintaining reflection-mode THz time-domain spectroscopy of a polyimide based ultra-thin narrow-band metamaterial absorber.

    PubMed

    Astorino, Maria Denise; Fastampa, Renato; Frezza, Fabrizio; Maiolo, Luca; Marrani, Marco; Missori, Mauro; Muzi, Marco; Tedeschi, Nicola; Veroli, Andrea

    2018-01-31

    This paper reports the design, the microfabrication and the experimental characterization of an ultra-thin narrow-band metamaterial absorber at terahertz frequencies. The metamaterial device is composed of a highly flexible polyimide spacer included between a top electric ring resonator with a four-fold rotational symmetry and a bottom ground plane that avoids misalignment problems. Its performance has been experimentally demonstrated by a custom polarization-maintaining reflection-mode terahertz time-domain spectroscopy system properly designed in order to reach a collimated configuration of the terahertz beam. The dependence of the spectral characteristics of this metamaterial absorber has been evaluated on the azimuthal angle under oblique incidence. The obtained absorbance levels are comprised between 67% and 74% at 1.092 THz and the polarization insensitivity has been verified in transverse electric polarization. This offers potential prospects in terahertz imaging, in terahertz stealth technology, in substance identification, and in non-planar applications. The proposed compact experimental set-up can be applied to investigate arbitrary polarization-sensitive terahertz devices under oblique incidence, allowing for a wide reproducibility of the measurements.

  6. Comparison of Scheimpflug imaging and spectral domain anterior segment optical coherence tomography for detection of narrow anterior chamber angles.

    PubMed

    Grewal, D S; Brar, G S; Jain, R; Grewal, S P S

    2011-05-01

    To compare the performance of anterior chamber volume (ACV) and anterior chamber depth (ACD) obtained using Scheimpflug imaging with angle opening distance (AOD500) and trabecular-iris space area (TISA500) obtained using spectral domain anterior segment optical coherence tomography (SD-ASOCT) in detecting narrow angles classified using gonioscopy. In this prospective, cross-sectional observational study, 265 eyes of 265 consecutive patients underwent sequential Scheimpflug imaging, SD-ASOCT imaging, and gonioscopy. Correlations between gonioscopy grading, ACV, ACD, AOD500, and TISA500 were evaluated. Area under receiver operating characteristic curve (AUC), sensitivity, specificity, and likelihood ratios (LRs) were calculated to assess the performance of ACV, ACD, AOD500, and TISA500 in detecting narrow angles (defined as Shaffer grade ≤1 in all quadrants). SD-ASOCT images were obtained at the nasal and temporal quadrants only. Twenty-eight eyes (10.6%) were classified as narrow angles on gonioscopy. ACV correlated with gonioscopy grading (P<0.001) for temporal (r=0.204), superior (r=0.251), nasal (r=0.213), and inferior (r=0.236) quadrants. ACV correlated with TISA500 for nasal (r=0.135, P=0.029) and temporal (P=0.160, P=0.009) quadrants and also with AOD500 for nasal (r=0.498, P<0.001) and temporal (r=0.517, P<0.001) quadrants. For detection of narrow angles, ACV (AUC=0.935; 95% confidence interval (CI) =0.898-0.961) performed similar to ACD (AUC=0.88, P=0.06) and significantly better than AOD500 nasal (AUC=0.761, P=0.001), AOD500 temporal (AUC=0.808, P<0.001), TISA500 nasal (AUC=0.756, P<0.001), and TISA500 temporal (AUC=0.738, P<0.001). Using a cutoff of 113 mm(3), ACV had 90% sensitivity and 88% specificity for detecting narrow angles. Positive and negative LRs for ACV were 8.63 (95% CI=7.4-10.0) and 0.11 (95% CI=0.03-0.4), respectively. ACV measurements using Scheimpflug imaging outperformed AOD500 and TISA500 using SD-ASOCT for detecting narrow angles.

  7. Comparison of Scheimpflug imaging and spectral domain anterior segment optical coherence tomography for detection of narrow anterior chamber angles

    PubMed Central

    Grewal, D S; Brar, G S; Jain, R; Grewal, S P S

    2011-01-01

    Purpose To compare the performance of anterior chamber volume (ACV) and anterior chamber depth (ACD) obtained using Scheimpflug imaging with angle opening distance (AOD500) and trabecular-iris space area (TISA500) obtained using spectral domain anterior segment optical coherence tomography (SD-ASOCT) in detecting narrow angles classified using gonioscopy. Methods In this prospective, cross-sectional observational study, 265 eyes of 265 consecutive patients underwent sequential Scheimpflug imaging, SD-ASOCT imaging, and gonioscopy. Correlations between gonioscopy grading, ACV, ACD, AOD500, and TISA500 were evaluated. Area under receiver operating characteristic curve (AUC), sensitivity, specificity, and likelihood ratios (LRs) were calculated to assess the performance of ACV, ACD, AOD500, and TISA500 in detecting narrow angles (defined as Shaffer grade ≤1 in all quadrants). SD-ASOCT images were obtained at the nasal and temporal quadrants only. Results Twenty-eight eyes (10.6%) were classified as narrow angles on gonioscopy. ACV correlated with gonioscopy grading (P<0.001) for temporal (r=0.204), superior (r=0.251), nasal (r=0.213), and inferior (r=0.236) quadrants. ACV correlated with TISA500 for nasal (r=0.135, P=0.029) and temporal (P=0.160, P=0.009) quadrants and also with AOD500 for nasal (r=0.498, P<0.001) and temporal (r=0.517, P<0.001) quadrants. For detection of narrow angles, ACV (AUC=0.935; 95% confidence interval (CI) =0.898–0.961) performed similar to ACD (AUC=0.88, P=0.06) and significantly better than AOD500 nasal (AUC=0.761, P=0.001), AOD500 temporal (AUC=0.808, P<0.001), TISA500 nasal (AUC=0.756, P<0.001), and TISA500 temporal (AUC=0.738, P<0.001). Using a cutoff of 113 mm3, ACV had 90% sensitivity and 88% specificity for detecting narrow angles. Positive and negative LRs for ACV were 8.63 (95% CI=7.4–10.0) and 0.11 (95% CI=0.03–0.4), respectively. Conclusions ACV measurements using Scheimpflug imaging outperformed AOD500 and TISA500 using

  8. A numerical approach to 14C wiggle-match dating of organic deposits: best fits and confidence intervals

    NASA Astrophysics Data System (ADS)

    Blaauw, Maarten; Heuvelink, Gerard B. M.; Mauquoy, Dmitri; van der Plicht, Johannes; van Geel, Bas

    2003-06-01

    14C wiggle-match dating (WMD) of peat deposits uses the non-linear relationship between 14C age and calendar age to match the shape of a sequence of closely spaced peat 14C dates with the 14C calibration curve. A numerical approach to WMD enables the quantitative assessment of various possible wiggle-match solutions and of calendar year confidence intervals for sequences of 14C dates. We assess the assumptions, advantages, and limitations of the method. Several case-studies show that WMD results in more precise chronologies than when individual 14C dates are calibrated. WMD is most successful during periods with major excursions in the 14C calibration curve (e.g., in one case WMD could narrow down confidence intervals from 230 to 36 yr).

  9. Intertrial interval duration and learning in autistic children.

    PubMed Central

    Koegel, R L; Dunlap, G; Dyer, K

    1980-01-01

    This study investigated the influence of intertrial interval duration on the performance of autistic children during teaching situations. The children were taught under the same conditions existing in their regular programs, except that the length of time between trials was systematically manipulated. With both multiple baseline and repeated reversal designs, two lengths of intertrial interval were employed; short intervals with the SD for any given trial presented approximately one second following the reinforcer for the previous trial versus long intervals with the SD presented four or more seconds following the reinforcer for the previous trial. The results showed that: (1) the short intertrial intervals always produced higher levels of correct responding than the long intervals; and (2) there were improving trends in performance and rapid acquisition with the short intertrial intervals, in contrast to minimal or no change with the long intervals. The results are discussed in terms of utilizing information about child and task characteristics in terms of selecting optimal intervals. The data suggest that manipulations made between trials have a large influence on autistic children's learning. PMID:7364701

  10. A tale of seven narrow spikes and a long trough: constraining the timing of the percolation of H II bubbles at the tail end of reionization with ULAS J1120+0641

    NASA Astrophysics Data System (ADS)

    Chardin, Jonathan; Haehnelt, Martin G.; Bosman, Sarah E. I.; Puchwein, Ewald

    2018-01-01

    High signal-to-noise observations of the Ly α forest transmissivity in the z = 7.085 quasi-stellar object (QSO) ULAS J1120+0641 show seven narrow transmission spikes followed by a long 240 cMpc h-1 trough. Here, we use radiative transfer simulations of cosmic reionization previously calibrated to match a wider range of Ly α forest data to show that the occurrence of seven transmission spikes in the narrow redshift range z = 5.85-6.1 is very sensitive to the exact timing of reionization. Occurrence of the spikes requires the most underdense regions of the intergalactic medium to be already fully ionized. The rapid onset of a long trough at z = 6.12 requires a strong decrease of the photoionization rate Γ at z ≳ 6.1 in this line of sight, consistent with the end of percolation at this redshift. The narrow range of reionization histories that we previously found to be consistent with a wider range of Ly α forest data have a reasonable probability of showing seven spikes and the mock absorption spectra provide an excellent match to the spikes and the trough in the observed spectrum of ULAS J1120+0641. Larger samples of high signal-to-noise searches for rare Ly α transmission spikes at z > 5.8 should therefore provide important further insights into the exact timing of the percolation of H II bubbles at the tail end of reionization.

  11. Effect of postmortem time interval on in vitro culture potential of goat skin tissues stored at room temperature.

    PubMed

    Singh, Mahipal; Ma, Xiaoling; Sharma, Anil

    2012-09-01

    Animal cloning using somatic cell nuclear transfer technology has renewed the interest in postmortem tissue storage, since these tissues can be used to reintroduce the lost genes back into the breeding pool in animal agriculture, preserve the genetic diversity, and revive the endangered species. However, for successful cloning of animals, integrity of nuclear DNA is essential. Cell viability and their potential to in vitro culture ensure nuclear integrity. The aim of this study was to determine the limits of postmortem time interval within which live cells can be recovered from goat skin tissues. To test the postmortem tissue storage limits, we cultured 2-3 mm(2) skin pieces (n = 70) from the ears of three breeds of goats (n = 7) after 0, 2, 4, and 6 days of postmortem storage at 24°C. After 10 days of culture, outgrowth of fibroblast-like cells (>50 cells) around the explants was scored. All the explants irrespective of breed displayed outgrowth of cells on the dish containing fresh tissues (i.e., day 0 of storage). However, the number of explants exhibiting outgrowth reduced with increasing time interval. Only 53.85 % explants displayed outgrowth after 2 days of tissue storage. The number of explants displaying outgrowth was much smaller after 4 (16.67 %) and 6 days (13.3 %) of storage. In general, the number of outgrowing cells per explant, on a given day, also decreased with increasing postmortem storage time interval. To test the differences between cell cultures, we established secondary cultures from one of the goats exhibiting outgrowth of cells after 6 days of tissue storage and compared them to similar cells from fresh tissues. Comparison of both the cell lines revealed similar cell morphology and growth curves and had doubling times of 23.04 and 22.56 h, respectively. These results suggest that live cells can be recovered from goat (and perhaps other animal) tissues stored at room temperature even after 6 days of their death with comparable growth

  12. The narrow pentaquark

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Diakonov, Dmitri

    2007-02-27

    The experimental status of the pentaquark searches is briefly reviewed. Recent null results by the CLAS collaboration are commented, and new strong evidence of a very narrow {theta}+ resonance by the DIANA collaboration is presented. On the theory side, I revisit the argument against the existence of the pentaquark - that of Callan and Klebanov - and show that actually a strong resonance is predicted in that approach, however its width is grossly overestimated. A recent calculation gives 2 MeV for the pentaquark width, and this number is probably still an upper bound.

  13. A novel interval type-2 fractional order fuzzy PID controller: Design, performance evaluation, and its optimal time domain tuning.

    PubMed

    Kumar, Anupam; Kumar, Vijay

    2017-05-01

    In this paper, a novel concept of an interval type-2 fractional order fuzzy PID (IT2FO-FPID) controller, which requires fractional order integrator and fractional order differentiator, is proposed. The incorporation of Takagi-Sugeno-Kang (TSK) type interval type-2 fuzzy logic controller (IT2FLC) with fractional controller of PID-type is investigated for time response measure due to both unit step response and unit load disturbance. The resulting IT2FO-FPID controller is examined on different delayed linear and nonlinear benchmark plants followed by robustness analysis. In order to design this controller, fractional order integrator-differentiator operators are considered as design variables including input-output scaling factors. A new hybridized algorithm named as artificial bee colony-genetic algorithm (ABC-GA) is used to optimize the parameters of the controller while minimizing weighted sum of integral of time absolute error (ITAE) and integral of square of control output (ISCO). To assess the comparative performance of the IT2FO-FPID, authors compared it against existing controllers, i.e., interval type-2 fuzzy PID (IT2-FPID), type-1 fractional order fuzzy PID (T1FO-FPID), type-1 fuzzy PID (T1-FPID), and conventional PID controllers. Furthermore, to show the effectiveness of the proposed controller, the perturbed processes along with the larger dead time are tested. Moreover, the proposed controllers are also implemented on multi input multi output (MIMO), coupled, and highly complex nonlinear two-link robot manipulator system in presence of un-modeled dynamics. Finally, the simulation results explicitly indicate that the performance of the proposed IT2FO-FPID controller is superior to its conventional counterparts in most of the cases. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  14. Online Doppler Effect Elimination Based on Unequal Time Interval Sampling for Wayside Acoustic Bearing Fault Detecting System

    PubMed Central

    Ouyang, Kesai; Lu, Siliang; Zhang, Shangbin; Zhang, Haibin; He, Qingbo; Kong, Fanrang

    2015-01-01

    The railway occupies a fairly important position in transportation due to its high speed and strong transportation capability. As a consequence, it is a key issue to guarantee continuous running and transportation safety of trains. Meanwhile, time consumption of the diagnosis procedure is of extreme importance for the detecting system. However, most of the current adopted techniques in the wayside acoustic defective bearing detector system (ADBD) are offline strategies, which means that the signal is analyzed after the sampling process. This would result in unavoidable time latency. Besides, the acquired acoustic signal would be corrupted by the Doppler effect because of high relative speed between the train and the data acquisition system (DAS). Thus, it is difficult to effectively diagnose the bearing defects immediately. In this paper, a new strategy called online Doppler effect elimination (ODEE) is proposed to remove the Doppler distortion online by the introduced unequal interval sampling scheme. The steps of proposed strategy are as follows: The essential parameters are acquired in advance. Then, the introduced unequal time interval sampling strategy is used to restore the Doppler distortion signal, and the amplitude of the signal is demodulated as well. Thus, the restored Doppler-free signal is obtained online. The proposed ODEE method has been employed in simulation analysis. Ultimately, the ODEE method is implemented in the embedded system for fault diagnosis of the train bearing. The results are in good accordance with the bearing defects, which verifies the good performance of the proposed strategy. PMID:26343657

  15. Assessment of the relationship between a narrow fragmented QRS complex and coronary slow flow.

    PubMed

    Cakmak, Huseyin Altug; Aslan, Serkan; Gul, Mehmet; Kalkan, Ali Kemal; Ozturk, Derya; Celik, Omer; Tasbulak, Omer; Satilmisoglu, Muhammet Hulusi

    2015-01-01

    The coronary slow flow (CSF) phenomenon is a delayed antegrade progression of contrast agent to the distal branch of a coronary artery in the absence of obstructive coronary artery disease (CAD). A narrow fragmented QRS (fQRS) has been reported as a significant predictor of sudden cardiac death in patients with idiopathic dilated cardiomyopathy. The present study aimed to investigate the relationship between a narrow fQRS on the admission electrocardiogram (ECG) and CSF on coronary angiography. This study included 165 consecutive patients (112 CSF, 53 controls) who underwent first-time diagnostic conventional coronary angiography for suspected CAD. Coronary flow was quantified by thrombolysis in myocardial infarction (TIMI) frame count (TFC). The patients were divided into two groups according to the presence or absence of a narrow fQRS complex on the admission ECG. Forty four patients were in the fQRS group (mean age, 52.97 ± 3.13 years). There was no difference between the two groups with respect to age, gender, body mass index, family history, hyperlipidemia, hypertension, or diabetes mellitus. The extent of CSF was significantly greater in the fQRS group compared to the non-fragmented group (p < 0.001). A significant correlation was also found between mean TFC values and fQRS (p < 0.001). On multivariate analysis, only CSF (p = 0.03) was a significant independent predictor for narrow fQRS, after adjustment for other parameters. The narrow fQRS is a simple, inexpensive, and readily available noninvasive ECG parameter that may be a new potential indicator of myocardial damage in patients with CSF.

  16. Time-interval for integration of stabilizing haptic and visual information in subjects balancing under static and dynamic conditions

    PubMed Central

    Honeine, Jean-Louis; Schieppati, Marco

    2014-01-01

    Maintaining equilibrium is basically a sensorimotor integration task. The central nervous system (CNS) continually and selectively weights and rapidly integrates sensory inputs from multiple sources, and coordinates multiple outputs. The weighting process is based on the availability and accuracy of afferent signals at a given instant, on the time-period required to process each input, and possibly on the plasticity of the relevant pathways. The likelihood that sensory inflow changes while balancing under static or dynamic conditions is high, because subjects can pass from a dark to a well-lit environment or from a tactile-guided stabilization to loss of haptic inflow. This review article presents recent data on the temporal events accompanying sensory transition, on which basic information is fragmentary. The processing time from sensory shift to reaching a new steady state includes the time to (a) subtract or integrate sensory inputs; (b) move from allocentric to egocentric reference or vice versa; and (c) adjust the calibration of motor activity in time and amplitude to the new sensory set. We present examples of processes of integration of posture-stabilizing information, and of the respective sensorimotor time-intervals while allowing or occluding vision or adding or subtracting tactile information. These intervals are short, in the order of 1–2 s for different postural conditions, modalities and deliberate or passive shift. They are just longer for haptic than visual shift, just shorter on withdrawal than on addition of stabilizing input, and on deliberate than unexpected mode. The delays are the shortest (for haptic shift) in blind subjects. Since automatic balance stabilization may be vulnerable to sensory-integration delays and to interference from concurrent cognitive tasks in patients with sensorimotor problems, insight into the processing time for balance control represents a critical step in the design of new balance- and locomotion training devices

  17. Galaxy properties from J-PAS narrow-band photometry

    NASA Astrophysics Data System (ADS)

    Mejía-Narváez, A.; Bruzual, G.; Magris, C. G.; Alcaniz, J. S.; Benítez, N.; Carneiro, S.; Cenarro, A. J.; Cristóbal-Hornillos, D.; Dupke, R.; Ederoclite, A.; Marín-Franch, A.; de Oliveira, C. Mendes; Moles, M.; Sodre, L.; Taylor, K.; Varela, J.; Ramió, H. Vázquez

    2017-11-01

    We study the consistency of the physical properties of galaxies retrieved from spectral energy distribution (SED) fitting as a function of spectral resolution and signal-to-noise ratio (SNR). Using a selection of physically motivated star formation histories, we set up a control sample of mock galaxy spectra representing observations of the local Universe in high-resolution spectroscopy, and in 56 narrow-band and 5 broad-band photometry. We fit the SEDs at these spectral resolutions and compute their corresponding stellar mass, the mass- and luminosity-weighted age and metallicity, and the dust extinction. We study the biases, correlations and degeneracies affecting the retrieved parameters and explore the role of the spectral resolution and the SNR in regulating these degeneracies. We find that narrow-band photometry and spectroscopy yield similar trends in the physical properties derived, the former being considerably more precise. Using a galaxy sample from the Sloan Digital Sky Survey (SDSS), we compare more realistically the results obtained from high-resolution and narrow-band SEDs (synthesized from the same SDSS spectra) following the same spectral fitting procedures. We use results from the literature as a benchmark to our spectroscopic estimates and show that the prior probability distribution functions, commonly adopted in parametric methods, may introduce biases not accounted for in a Bayesian framework. We conclude that narrow-band photometry yields the same trend in the age-metallicity relation in the literature, provided it is affected by the same biases as spectroscopy, albeit the precision achieved with the latter is generally twice as large as with the narrow-band, at SNR values typical of the different kinds of data.

  18. Variations in rupture process with recurrence interval in a repeated small earthquake

    USGS Publications Warehouse

    Vidale, J.E.; Ellsworth, W.L.; Cole, A.; Marone, Chris

    1994-01-01

    In theory and in laboratory experiments, friction on sliding surfaces such as rock, glass and metal increases with time since the previous episode of slip. This time dependence is a central pillar of the friction laws widely used to model earthquake phenomena. On natural faults, other properties, such as rupture velocity, porosity and fluid pressure, may also vary with the recurrence interval. Eighteen repetitions of the same small earthquake, separated by intervals ranging from a few days to several years, allow us to test these laboratory predictions in situ. The events with the longest time since the previous earthquake tend to have about 15% larger seismic moment than those with the shortest intervals, although this trend is weak. In addition, the rupture durations of the events with the longest recurrence intervals are more than a factor of two shorter than for the events with the shortest intervals. Both decreased duration and increased friction are consistent with progressive fault healing during the time of stationary contact.In theory and in laboratory experiments, friction on sliding surfaces such as rock, glass and metal increases with time since the previous episode of slip. This time dependence is a central pillar of the friction laws widely used to model earthquake phenomena. On natural faults, other properties, such as rupture velocity, porosity and fluid pressure, may also vary with the recurrence interval. Eighteen repetitions of the same small earthquake, separated by intervals ranging from a few days to several years, allow us to test these laboratory predictions in situ. The events with the longest time since the previous earthquake tend to have about 15% larger seismic moment than those with the shortest intervals, although this trend is weak. In addition, the rupture durations of the events with the longest recurrence intervals are more than a factor of two shorter than for the events with the shortest intervals. Both decreased duration and

  19. Binary Interval Search: a scalable algorithm for counting interval intersections.

    PubMed

    Layer, Ryan M; Skadron, Kevin; Robins, Gabriel; Hall, Ira M; Quinlan, Aaron R

    2013-01-01

    The comparison of diverse genomic datasets is fundamental to understand genome biology. Researchers must explore many large datasets of genome intervals (e.g. genes, sequence alignments) to place their experimental results in a broader context and to make new discoveries. Relationships between genomic datasets are typically measured by identifying intervals that intersect, that is, they overlap and thus share a common genome interval. Given the continued advances in DNA sequencing technologies, efficient methods for measuring statistically significant relationships between many sets of genomic features are crucial for future discovery. We introduce the Binary Interval Search (BITS) algorithm, a novel and scalable approach to interval set intersection. We demonstrate that BITS outperforms existing methods at counting interval intersections. Moreover, we show that BITS is intrinsically suited to parallel computing architectures, such as graphics processing units by illustrating its utility for efficient Monte Carlo simulations measuring the significance of relationships between sets of genomic intervals. https://github.com/arq5x/bits.

  20. The Effect of Divided Attention on Emotion-Induced Memory Narrowing

    PubMed Central

    Steinmetz, Katherine R. Mickley; Waring, Jill D.; Kensinger, Elizabeth A.

    2014-01-01

    Individuals are more likely to remember emotional than neutral information, but this benefit does not always extend to the surrounding background information. This memory narrowing is theorized to be linked to the availability of attentional resources at encoding. In contrast to the predictions of this theoretical account, altering participants’ attentional resources at encoding, by dividing attention, did not affect the emotion-induced memory narrowing. Attention was divided using three separate manipulations: a digit ordering task (Experiment 1), an arithmetic task (Experiment 2), and an auditory discrimination task (Experiment 3). Across all three experiments, divided attention decreased memory across-the-board but did not affect the degree of memory narrowing. These findings suggest that theories to explain memory narrowing must be expanded to include other potential mechanisms beyond limitations of attentional resources. PMID:24295041

  1. The effect of divided attention on emotion-induced memory narrowing.

    PubMed

    Mickley Steinmetz, Katherine R; Waring, Jill D; Kensinger, Elizabeth A

    2014-01-01

    Individuals are more likely to remember emotional than neutral information, but this benefit does not always extend to the surrounding background information. This memory narrowing is theorised to be linked to the availability of attentional resources at encoding. In contrast to the predictions of this theoretical account, altering participants' attentional resources at encoding by dividing attention did not affect emotion-induced memory narrowing. Attention was divided using three separate manipulations: a digit ordering task (Experiment 1), an arithmetic task (Experiment 2) and an auditory discrimination task (Experiment 3). Across all three experiments, divided attention decreased memory across the board but did not affect the degree of memory narrowing. These findings suggest that theories to explain memory narrowing must be expanded to include other potential mechanisms beyond the limitations of attentional resources.

  2. Linewidth narrowing for 31Phosphorus MRI of cell membranes

    NASA Astrophysics Data System (ADS)

    Barrett, Sean; Frey, Merideth; Madri, Joseph; Michaud, Michael

    2011-03-01

    Most 31 P Magnetic Resonance Spectroscopy studies of tissues try to avoid contamination by a relatively large, but broad, spectral feature attributed to cell membrane phospholipids. MRI using this broad 31 P membrane spectrum is not even attempted, since the spatial resolution and signal-to-noise would be poor, relative to conventional MRI using the narrow 1 H water spectrum. This long-standing barrier has been overcome by a novel pulse sequence, recently discovered in fundamental quantum computation research, which narrows the broad 31 P spectrum by ~ 1000 × . Applying time-dependent gradients in synch with a repeating pulse block enables a new route to high spatial resolution, 3D 31 P MRI of the soft solid components of cells and tissues. So far, intact and sectioned samples of ex vivo fixed mouse organs have been imaged, with (sub-mm)3 voxels. Extending the reach of MRI to broad spectra in natural and artificial tissues opens a new window into cells, enabling progress in biomedical research. W.J. Thoma et al., J. MR 61, 141 (1985); E.J. Murphy et al., MR Med 12, 282 (1989); R. McNamara et al., NMR Biomed 7, 237 (1994).

  3. Measurement of Trained Speech Patterns in Stuttering: Interjudge and Intrajudge Agreement of Experts by Means of Modified Time-Interval Analysis

    ERIC Educational Resources Information Center

    Alpermann, Anke; Huber, Walter; Natke, Ulrich; Willmes, Klaus

    2010-01-01

    Improved fluency after stuttering therapy is usually measured by the percentage of stuttered syllables. However, outcome studies rarely evaluate the use of trained speech patterns that speakers use to manage stuttering. This study investigated whether the modified time interval analysis can distinguish between trained speech patterns, fluent…

  4. Method of high precision interval measurement in pulse laser ranging system

    NASA Astrophysics Data System (ADS)

    Wang, Zhen; Lv, Xin-yuan; Mao, Jin-jin; Liu, Wei; Yang, Dong

    2013-09-01

    Laser ranging is suitable for laser system, for it has the advantage of high measuring precision, fast measuring speed,no cooperative targets and strong resistance to electromagnetic interference,the measuremen of laser ranging is the key paremeters affecting the performance of the whole system.The precision of the pulsed laser ranging system was decided by the precision of the time interval measurement, the principle structure of laser ranging system was introduced, and a method of high precision time interval measurement in pulse laser ranging system was established in this paper.Based on the analysis of the factors which affected the precision of range measure,the pulse rising edges discriminator was adopted to produce timing mark for the start-stop time discrimination,and the TDC-GP2 high precision interval measurement system based on TMS320F2812 DSP was designed to improve the measurement precision.Experimental results indicate that the time interval measurement method in this paper can obtain higher range accuracy. Compared with the traditional time interval measurement system,the method simplifies the system design and reduce the influence of bad weather conditions,furthermore,it satisfies the requirements of low costs and miniaturization.

  5. Bayesian Face Recognition and Perceptual Narrowing in Face-Space

    ERIC Educational Resources Information Center

    Balas, Benjamin

    2012-01-01

    During the first year of life, infants' face recognition abilities are subject to "perceptual narrowing", the end result of which is that observers lose the ability to distinguish previously discriminable faces (e.g. other-race faces) from one another. Perceptual narrowing has been reported for faces of different species and different races, in…

  6. Brain response during the M170 time interval is sensitive to socially relevant information.

    PubMed

    Arviv, Oshrit; Goldstein, Abraham; Weeting, Janine C; Becker, Eni S; Lange, Wolf-Gero; Gilboa-Schechtman, Eva

    2015-11-01

    Deciphering the social meaning of facial displays is a highly complex neurological process. The M170, an event related field component of MEG recording, like its EEG counterpart N170, was repeatedly shown to be associated with structural encoding of faces. However, the scope of information encoded during the M170 time window is still being debated. We investigated the neuronal origin of facial processing of integrated social rank cues (SRCs) and emotional facial expressions (EFEs) during the M170 time interval. Participants viewed integrated facial displays of emotion (happy, angry, neutral) and SRCs (indicated by upward, downward, or straight head tilts). We found that the activity during the M170 time window is sensitive to both EFEs and SRCs. Specifically, highly prominent activation was observed in response to SRC connoting dominance as compared to submissive or egalitarian head cues. Interestingly, the processing of EFEs and SRCs appeared to rely on different circuitry. Our findings suggest that vertical head tilts are processed not only for their sheer structural variance, but as social information. Exploring the temporal unfolding and brain localization of non-verbal cues processing may assist in understanding the functioning of the social rank biobehavioral system. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Differential Changes in Myocardial Performance Index and Its Time Intervals in Donors and Recipients of Twin-to-Twin Transfusion Syndrome before and after Laser Therapy.

    PubMed

    Ortiz, Javier U; Torres, Ximena; Eixarch, Elisenda; Bennasar, Mar; Cruz-Lemini, Monica; Gómez, Olga; Lobmaier, Silvia M; Martínez, Josep M; Gratacós, Eduard; Crispi, Fatima

    2018-01-19

    To evaluate left myocardial performance index (MPI) and time intervals in fetuses with twin-to-twin transfusion syndrome (TTTS) before and after laser surgery. Fifty-one fetal pairs with TTTS and 47 uncomplicated monochorionic twin pairs were included. Left ventricular isovolumetric contraction time (ICT), ejection time (ET), and isovolumetric relaxation time (IRT) were measured using conventional Doppler. Recipients showed prolonged ICT (46 ± 12 vs. 31 ± 8 vs. 30 ± 5 ms; p < 0.001) and IRT (51 ± 9 vs. 43 ± 8 vs. 43 ± 5 ms; p < 0.001) and higher MPI (0.57 ± 0.12 vs. 0.47 ± 0.09 vs. 0.44 ± 0.05; p < 0.001) than donors and controls. Donors showed shorter ET than recipients and controls (157 ± 12 vs. 169 ± 10 vs. 168 ± 10 ms; p < 0.001) and higher MPI than controls (0.47 ± 0.09 vs. 0.44 ± 0.05; p = 0.006). Preoperative MPI changes were observed in all TTTS stages. Time intervals partially improved after surgery. Donor and recipient twins had higher MPI due to different changes in the time intervals, possibly reflecting the state of hypovolemia in the donor and hypervolemia and pressure overload in the recipient. © 2018 S. Karger AG, Basel.

  8. Asymptotic analysis of the narrow escape problem in dendritic spine shaped domain: three dimensions

    NASA Astrophysics Data System (ADS)

    Li, Xiaofei; Lee, Hyundae; Wang, Yuliang

    2017-08-01

    This paper deals with the three-dimensional narrow escape problem in a dendritic spine shaped domain, which is composed of a relatively big head and a thin neck. The narrow escape problem is to compute the mean first passage time of Brownian particles traveling from inside the head to the end of the neck. The original model is to solve a mixed Dirichlet-Neumann boundary value problem for the Poisson equation in the composite domain, and is computationally challenging. In this paper we seek to transfer the original problem to a mixed Robin-Neumann boundary value problem by dropping the thin neck part, and rigorously derive the asymptotic expansion of the mean first passage time with high order terms. This study is a nontrivial three-dimensional generalization of the work in Li (2014 J. Phys. A: Math. Theor. 47 505202), where a two-dimensional analogue domain is considered.

  9. Spectral of electrocardiographic RR intervals to indicate atrial fibrillation

    NASA Astrophysics Data System (ADS)

    Nuryani, Nuryani; Satrio Nugroho, Anto

    2017-11-01

    Atrial fibrillation is a serious heart diseases, which is associated on the risk of death, and thus an early detection of atrial fibrillation is necessary. We have investigated spectral pattern of electrocardiogram in relation to atrial fibrillation. The utilized feature of electrocardiogram is RR interval. RR interval is the time interval between a two-consecutive R peaks. A series of RR intervals in a time segment is converted to a signal with a frequency domain. The frequency components are investigated to find the components which significantly associate to atrial fibrillation. A segment is defined as atrial fibrillation or normal segments by considering a defined number of atrial fibrillation RR in the segment. Using clinical data of 23 patients with atrial fibrillation, we find that the frequency components could be used to indicate atrial fibrillation.

  10. Very narrow excited Ωc baryons

    NASA Astrophysics Data System (ADS)

    Karliner, Marek; Rosner, Jonathan L.

    2017-06-01

    Recently, LHCb reported the discovery of five extremely narrow excited Ωc baryons decaying into Ξc+K-. We interpret these baryons as bound states of a c quark and a P -wave s s diquark. For such a system, there are exactly five possible combinations of spin and orbital angular momentum. The narrowness of the states could be a signal that it is hard to pull apart the two s quarks in a diquark. We predict two of spin 1 /2 , two of spin 3 /2 , and one of spin 5 /2 , all with negative parity. Of the five states, two can decay in S -wave, and three can decay in D -wave. Some of the D -wave states might be narrower than the S -wave states. We discuss the relations among the five masses expected in the quark model and the likely spin assignments, and we compare them with the data. A similar pattern is expected for negative-parity excited Ωb states. An alternative interpretation is noted in which the heaviest two states are 2 S excitations with JP=1 /2+ and 3 /2+, while the lightest three are those with JP=3 /2- , 3 /2- , 5 /2- , expected to decay via D -waves. In this case, we expect JP=1 /2- Ωc states around 2904 and 2978 MeV.

  11. Overconfidence in Interval Estimates

    ERIC Educational Resources Information Center

    Soll, Jack B.; Klayman, Joshua

    2004-01-01

    Judges were asked to make numerical estimates (e.g., "In what year was the first flight of a hot air balloon?"). Judges provided high and low estimates such that they were X% sure that the correct answer lay between them. They exhibited substantial overconfidence: The correct answer fell inside their intervals much less than X% of the time. This…

  12. Binary Interval Search: a scalable algorithm for counting interval intersections

    PubMed Central

    Layer, Ryan M.; Skadron, Kevin; Robins, Gabriel; Hall, Ira M.; Quinlan, Aaron R.

    2013-01-01

    Motivation: The comparison of diverse genomic datasets is fundamental to understand genome biology. Researchers must explore many large datasets of genome intervals (e.g. genes, sequence alignments) to place their experimental results in a broader context and to make new discoveries. Relationships between genomic datasets are typically measured by identifying intervals that intersect, that is, they overlap and thus share a common genome interval. Given the continued advances in DNA sequencing technologies, efficient methods for measuring statistically significant relationships between many sets of genomic features are crucial for future discovery. Results: We introduce the Binary Interval Search (BITS) algorithm, a novel and scalable approach to interval set intersection. We demonstrate that BITS outperforms existing methods at counting interval intersections. Moreover, we show that BITS is intrinsically suited to parallel computing architectures, such as graphics processing units by illustrating its utility for efficient Monte Carlo simulations measuring the significance of relationships between sets of genomic intervals. Availability: https://github.com/arq5x/bits. Contact: arq5x@virginia.edu Supplementary information: Supplementary data are available at Bioinformatics online. PMID:23129298

  13. Hydrographic surveys of four narrows within the Namakan reservoir system, Voyageurs National Park, Minnesota, 2011

    USGS Publications Warehouse

    Densmore, Brenda K.; Strauch, Kellan R.; Ziegeweid, Jeffrey R.

    2013-01-01

    The U.S. Geological Survey performed multibeam echosounder hydrographic surveys of four narrows in the Namakan reservoir system in August 2011, in cooperation with the International Joint Commission and Environment Canada. The data-collection effort was completed to provide updated and detailed hydrographic data to Environment Canada for inclusion in a Hydrologic Engineering Centers River Analysis System hydraulic model. The Namakan reservoir system is composed of Namakan, Kabetogama, Sand Point, Crane, and Little Vermilion Lakes. Water elevations in the Namakan reservoir system are regulated according to rule curves, or guidelines for water-level management based on the time of year, established by the International Joint Commission. Water levels are monitored by established gages on Crane Lake and the outlet of Namakan Lake at Kettle Falls, but water elevations throughout the system may deviate from these measured values by as much as 0.3 meters, according to lake managers and residents. Deviations from expected water elevations may be caused by between-lake constrictions (narrows). According to the 2000 Rule Curve Assessment Workgroup, hydrologic models of the reservoir system are needed to better understand the system and to evaluate the recent changes made to rule curves in 2000. Hydrographic surveys were performed using a RESON SeaBat™7125 multibeam echosounder system. Surveys were completed at Namakan Narrows, Harrison Narrows, King Williams Narrows, and Little Vermilion Narrows. Hydrographic survey data were processed using Caris HIPSTM and SIPSTM software that interpolated a combined uncertainty and bathymetric estimator (CUBE) surface. Quality of the survey results was evaluated in relation to standards set by the International Hydrographic Organization (IHO) for describing the uncertainty of hydrographic surveys. More than 90 percent of the surveyed areas at the four narrows have resulting bed elevations that meet the IHO “Special Order” quality

  14. The influence of interpregnancy interval on infant mortality.

    PubMed

    McKinney, David; House, Melissa; Chen, Aimin; Muglia, Louis; DeFranco, Emily

    2017-03-01

    In Ohio, the infant mortality rate is above the national average and the black infant mortality rate is more than twice the white infant mortality rate. Having a short interpregnancy interval has been shown to correlate with preterm birth and low birthweight, but the effect of short interpregnancy interval on infant mortality is less well established. We sought to quantify the population impact of interpregnancy interval on the risk of infant mortality. This was a statewide population-based retrospective cohort study of all births (n = 1,131,070) and infant mortalities (n = 8152) using linked Ohio birth and infant death records from January 2007 through September 2014. For this study we analyzed 5 interpregnancy interval categories: 0-<6, 6-<12, 12-<24, 24-<60, and ≥60 months. The primary outcome for this study was infant mortality. During the study period, 3701 infant mortalities were linked to a live birth certificate with an interpregnancy interval available. We calculated the frequency and relative risk of infant mortality for each interval compared to a referent interval of 12-<24 months. Stratified analyses by maternal race were also performed. Adjusted risks were estimated after accounting for statistically significant and biologically plausible confounding variables. Adjusted relative risk was utilized to calculate the attributable risk percent of short interpregnancy intervals on infant mortality. Short interpregnancy intervals were common in Ohio during the study period. Of all multiparous births, 20.5% followed an interval of <12 months. The overall infant mortality rate during this time was 7.2 per 1000 live births (6.0 for white mothers and 13.1 for black mothers). Infant mortalities occurred more frequently for births following short intervals of 0-<6 months (9.2 per 1000) and 6-<12 months (7.1 per 1000) compared to 12-<24 months (5.6 per 1000) (P < .001 and <.001). The highest risk for infant mortality followed interpregnancy intervals of 0

  15. RR-Interval variance of electrocardiogram for atrial fibrillation detection

    NASA Astrophysics Data System (ADS)

    Nuryani, N.; Solikhah, M.; Nugoho, A. S.; Afdala, A.; Anzihory, E.

    2016-11-01

    Atrial fibrillation is a serious heart problem originated from the upper chamber of the heart. The common indication of atrial fibrillation is irregularity of R peak-to-R-peak time interval, which is shortly called RR interval. The irregularity could be represented using variance or spread of RR interval. This article presents a system to detect atrial fibrillation using variances. Using clinical data of patients with atrial fibrillation attack, it is shown that the variance of electrocardiographic RR interval are higher during atrial fibrillation, compared to the normal one. Utilizing a simple detection technique and variances of RR intervals, we find a good performance of atrial fibrillation detection.

  16. Respiratory variation of systolic and diastolic time intervals within radial arterial waveform: a comparison with dynamic preload index.

    PubMed

    Park, Ji Hyun; Hwang, Gyu-Sam

    2016-08-01

    A blood pressure (BP) waveform contains various pieces of information related to respiratory variation. Systolic time interval (STI) reflects myocardial performance, and diastolic time interval (DTI) represents diastolic filling. This study examined whether respiratory variations of STI and DTI within radial arterial waveform are comparable to dynamic indices. During liver transplantation, digitally recorded BP waveform and stroke volume variation (SVV) were retrospectively analyzed. Beat-to-beat STI and DTI were extracted within each BP waveform, which were separated by dicrotic notch. Systolic time variation (STV) was calculated by the average of 3 consecutive respiratory cycles: [(STImax- STImin)/STImean]. Similar formula was used for diastolic time variation (DTV) and pulse pressure variation (PPV). Receiver operating characteristic analysis with area under the curve (AUC) was used to assess thresholds predictive of SVV ≥12% and PPV ≥12%. STV and DTV showed significant correlations with SVV (r= 0.78 and r= 0.67, respectively) and PPV (r= 0.69 and r= 0.69, respectively). Receiver operating characteristic curves demonstrated that STV ≥11% identified to predict SVV ≥12% with 85.7% sensitivity and 89.3% specificity (AUC = 0.935; P< .001). DTV ≥11% identified to predict SVV ≥12% with 71.4% sensitivity and 85.7% specificity (AUC = 0.829; P< .001). STV ≥12% and DTV ≥11% identified to predict PPV ≥12% with an AUC of 0.881 and 0.885, respectively. Respiratory variations of STI and DTI derived from radial arterial contour have a potential to predict hemodynamic response as a surrogate for SVV or PPV. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Pigeons' Choices between Fixed-Interval and Random-Interval Schedules: Utility of Variability?

    ERIC Educational Resources Information Center

    Andrzejewski, Matthew E.; Cardinal, Claudia D.; Field, Douglas P.; Flannery, Barbara A.; Johnson, Michael; Bailey, Kathleen; Hineline, Philip N.

    2005-01-01

    Pigeons' choosing between fixed-interval and random-interval schedules of reinforcement was investigated in three experiments using a discrete-trial procedure. In all three experiments, the random-interval schedule was generated by sampling a probability distribution at an interval (and in multiples of the interval) equal to that of the…

  18. MK-801 and memantine act differently on short-term memory tested with different time-intervals in the Morris water maze test.

    PubMed

    Duda, Weronika; Wesierska, Malgorzata; Ostaszewski, Pawel; Vales, Karel; Nekovarova, Tereza; Stuchlik, Ales

    2016-09-15

    N-methyl-d-aspartate receptors (NMDARs) play a crucial role in spatial memory formation. In neuropharmacological studies their functioning strongly depends on testing conditions and the dosage of NMDAR antagonists. The aim of this study was to assess the immediate effects of NMDAR block by (+)MK-801 or memantine on short-term allothetic memory. Memory was tested in a working memory version of the Morris water maze test. In our version of the test, rats underwent one day of training with 8 trials, and then three experimental days when rats were injected intraperitoneally with low- 5 (MeL), high - 20 (MeH) mg/kg memantine, 0.1mg/kg MK-801 or 1ml/kg saline (SAL) 30min before testing, for three consecutive days. On each experimental day there was just one acquisition and one test trial, with an inter-trial interval of 5 or 15min. During training the hidden platform was relocated after each trial and during the experiment after each day. The follow-up effect was assessed on day 9. Intact rats improved their spatial memory across the one training day. With a 5min interval MeH rats had longer latency then all rats during retrieval. With a 15min interval the MeH rats presented worse working memory measured as retrieval minus acquisition trial for path than SAL and MeL and for latency than MeL rats. MK-801 rats had longer latency than SAL during retrieval. Thus, the high dose of memantine, contrary to low dose of MK-801 disrupts short-term memory independent on the time interval between acquisition and retrieval. This shows that short-term memory tested in a working memory version of water maze is sensitive to several parameters: i.e., NMDA receptor antagonist type, dosage and the time interval between learning and testing. Copyright © 2016. Published by Elsevier B.V.

  19. Finding Intervals of Abrupt Change in Earth Science Data

    NASA Astrophysics Data System (ADS)

    Zhou, X.; Shekhar, S.; Liess, S.

    2011-12-01

    In earth science data (e.g., climate data), it is often observed that a persistently abrupt change in value occurs in a certain time-period or spatial interval. For example, abrupt climate change is defined as an unusually large shift of precipitation, temperature, etc, that occurs during a relatively short time period. A similar pattern can also be found in geographical space, representing a sharp transition of the environment (e.g., vegetation between different ecological zones). Identifying such intervals of change from earth science datasets is a crucial step for understanding and attributing the underlying phenomenon. However, inconsistencies in these noisy datasets can obstruct the major change trend, and more importantly can complicate the search of the beginning and end points of the interval of change. Also, the large volume of data makes it challenging to process the dataset reasonably fast. In earth science data (e.g., climate data), it is often observed that a persistently abrupt change in value occurs in a certain time-period or spatial interval. For example, abrupt climate change is defined as an unusually large shift of precipitation, temperature, etc, that occurs during a relatively short time period. A similar change pattern can also be found in geographical space, representing a sharp transition of the environment (e.g., vegetation between different ecological zones). Identifying such intervals of change from earth science datasets is a crucial step for understanding and attributing the underlying phenomenon. However, inconsistencies in these noisy datasets can obstruct the major change trend, and more importantly can complicate the search of the beginning and end points of the interval of change. Also, the large volume of data makes it challenging to process the dataset fast. In this work, we analyze earth science data using a novel, automated data mining approach to identify spatial/temporal intervals of persistent, abrupt change. We first

  20. Fluctuations of healthy and unhealthy heartbeat intervals

    NASA Astrophysics Data System (ADS)

    Lan, Boon Leong; Toda, Mikito

    2013-04-01

    We show that the RR-interval fluctuations, defined as the difference between successive natural-logarithm of the RR interval, for healthy, congestive-heart-failure (CHF) and atrial-fibrillation (AF) subjects are well modeled by non-Gaussian stable distributions. Our results suggest that healthy or unhealthy RR-interval fluctuation can generally be modeled as a sum of a large number of independent physiological effects which are identically distributed with infinite variance. Furthermore, we show for the first time that one indicator —the scale parameter of the stable distribution— is sufficient to robustly distinguish the three groups of subjects. The scale parameters for healthy subjects are smaller than those for AF subjects but larger than those for CHF subjects —this ordering suggests that the scale parameter could be used to objectively quantify the severity of CHF and AF over time and also serve as an early warning signal for a healthy person when it approaches either boundary of the healthy range.

  1. Bandwidth-narrowed Bragg gratings inscribed in double-cladding fiber by femtosecond laser.

    PubMed

    Shi, Jiawei; Li, Yuhua; Liu, Shuhui; Wang, Haiyan; Liu, Ningliang; Lu, Peixiang

    2011-01-31

    Bragg gratings with the bandwidth(FWHM) narrowed up to 79 pm were inscribed in double-cladding fiber with femtosecond radiation and a phase mask followed by an annealing treatment. With the annealing temperature below a critical value, the bandwidth of Bragg gratings induced by Type I-IR and Type II-IR index change was narrowed without the reduction of reflectivity. The bandwidth narrowing is due to the profile transformation of the refractive index modulation caused by the annealing treatment. This mechanism was verified by comparing bandwidth narrowing processes of FBGs written with different power densities.

  2. 3. Photocopied July 1971 from Photo 741, Jordan Narrows Folder ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. Photocopied July 1971 from Photo 741, Jordan Narrows Folder #1, Engineering Department, Utah Power and Light Co., Salt Lake City, Utah. INTERIOR VIEW, JULY 2, 1909. - Salt Lake City Water & Electrical Power Company, Jordan Narrows Hydroelectric Plant, Jordan River, Riverton, Salt Lake County, UT

  3. Optimal Measurement Interval for Emergency Department Crowding Estimation Tools.

    PubMed

    Wang, Hao; Ojha, Rohit P; Robinson, Richard D; Jackson, Bradford E; Shaikh, Sajid A; Cowden, Chad D; Shyamanand, Rath; Leuck, JoAnna; Schrader, Chet D; Zenarosa, Nestor R

    2017-11-01

    Emergency department (ED) crowding is a barrier to timely care. Several crowding estimation tools have been developed to facilitate early identification of and intervention for crowding. Nevertheless, the ideal frequency is unclear for measuring ED crowding by using these tools. Short intervals may be resource intensive, whereas long ones may not be suitable for early identification. Therefore, we aim to assess whether outcomes vary by measurement interval for 4 crowding estimation tools. Our eligible population included all patients between July 1, 2015, and June 30, 2016, who were admitted to the JPS Health Network ED, which serves an urban population. We generated 1-, 2-, 3-, and 4-hour ED crowding scores for each patient, using 4 crowding estimation tools (National Emergency Department Overcrowding Scale [NEDOCS], Severely Overcrowded, Overcrowded, and Not Overcrowded Estimation Tool [SONET], Emergency Department Work Index [EDWIN], and ED Occupancy Rate). Our outcomes of interest included ED length of stay (minutes) and left without being seen or eloped within 4 hours. We used accelerated failure time models to estimate interval-specific time ratios and corresponding 95% confidence limits for length of stay, in which the 1-hour interval was the reference. In addition, we used binomial regression with a log link to estimate risk ratios (RRs) and corresponding confidence limit for left without being seen. Our study population comprised 117,442 patients. The time ratios for length of stay were similar across intervals for each crowding estimation tool (time ratio=1.37 to 1.30 for NEDOCS, 1.44 to 1.37 for SONET, 1.32 to 1.27 for EDWIN, and 1.28 to 1.23 for ED Occupancy Rate). The RRs of left without being seen differences were also similar across intervals for each tool (RR=2.92 to 2.56 for NEDOCS, 3.61 to 3.36 for SONET, 2.65 to 2.40 for EDWIN, and 2.44 to 2.14 for ED Occupancy Rate). Our findings suggest limited variation in length of stay or left without being

  4. A 3.9 ps Time-Interval RMS Precision Time-to-Digital Converter Using a Dual-Sampling Method in an UltraScale FPGA

    NASA Astrophysics Data System (ADS)

    Wang, Yonggang; Liu, Chong

    2016-10-01

    Field programmable gate arrays (FPGAs) manufactured with more advanced processing technology have faster carry chains and smaller delay elements, which are favorable for the design of tapped delay line (TDL)-style time-to-digital converters (TDCs) in FPGA. However, new challenges are posed in using them to implement TDCs with a high time precision. In this paper, we propose a bin realignment method and a dual-sampling method for TDC implementation in a Xilinx UltraScale FPGA. The former realigns the disordered time delay taps so that the TDC precision can approach the limit of its delay granularity, while the latter doubles the number of taps in the delay line so that the TDC precision beyond the cell delay limitation can be expected. Two TDC channels were implemented in a Kintex UltraScale FPGA, and the effectiveness of the new methods was evaluated. For fixed time intervals in the range from 0 to 440 ns, the average RMS precision measured by the two TDC channels reaches 5.8 ps using the bin realignment, and it further improves to 3.9 ps by using the dual-sampling method. The time precision has a 5.6% variation in the measured temperature range. Every part of the TDC, including dual-sampling, encoding, and on-line calibration, could run at a 500 MHz clock frequency. The system measurement dead time is only 4 ns.

  5. The effects of morphine on fixed-interval patterning and temporal discrimination.

    PubMed Central

    Odum, A L; Schaal, D W

    2000-01-01

    Changes produced by drugs in response patterns under fixed-interval schedules of reinforcement have been interpreted to result from changes in temporal discrimination. To examine this possibility, this experiment determined the effects of morphine on the response patterning of 4 pigeons during a fixed-interval 1-min schedule of food delivery with interpolated temporal discrimination trials. Twenty of the 50 total intervals were interrupted by choice trials. Pecks to one key color produced food if the interval was interrupted after a short time (after 2 or 4.64 s). Pecks to another key color produced food if the interval was interrupted after a long time (after 24.99 or 58 s). Morphine (1.0 to 10.0 mg/kg) decreased the index of curvature (a measure of response patterning) during fixed intervals and accuracy during temporal discrimination trials. Accuracy was equally disrupted following short and long sample durations. Although morphine disrupted temporal discrimination in the context of a fixed-interval schedule, these effects are inconsistent with interpretations of the disruption of response patterning as a selective overestimation of elapsed time. The effects of morphine may be related to the effects of more conventional external stimuli on response patterning. PMID:11029024

  6. 1. Photocopied July 1971 from Photo 745, Jordan Narrows Folder ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. Photocopied July 1971 from Photo 745, Jordan Narrows Folder #1, Engineering Department, Utah Power and Light Co., Salt Lake City, Utah. JORDAN STATION, JULY 2, 1909. GENERAL VIEW. - Salt Lake City Water & Electrical Power Company, Jordan Narrows Hydroelectric Plant, Jordan River, Riverton, Salt Lake County, UT

  7. Decreased airway narrowing and smooth muscle contraction in hyperresponsive pigs.

    PubMed

    Turner, Debra J; Noble, Peter B; Lucas, Matthew P; Mitchell, Howard W

    2002-10-01

    Increased smooth muscle contractility or reduced smooth muscle mechanical loads could account for the excessive airway narrowing and hyperresponsiveness seen in asthma. These mechanisms were investigated by using an allergen-induced porcine model of airway hyperresponsiveness. Airway narrowing to electric field stimulation was measured in isolated bronchial segments, over a range of transmural pressures (0-20 cmH(2)O). Contractile responses to ACh were measured in bronchial segments and in isolated tracheal smooth muscle strips isolated from control and test (ovalbumin sensitized and challenged) pigs. Test airways narrowed less than controls (P < 0.0001). Test pigs showed reduced contractility to ACh, both in isolated bronchi (P < 0.01) and smooth muscle strips (P < 0.01). Thus isolated airways from pigs exhibiting airway hyperresponsiveness in vivo are hyporesponsive in vitro. The decreased narrowing in bronchi from hyperresponsive pigs may be related to decreased smooth muscle contractility. These data suggest that mechanisms external to the airway wall may be important to the hyperresponsive nature of sensitized lungs.

  8. Photovoltaic measurement of bandgap narrowing in moderately doped silicon

    NASA Astrophysics Data System (ADS)

    del Alamo, Jesus A.; Swanson, Richard M.; Lietoila, Arto

    1983-05-01

    Solar cells have been fabricated on n-type and p-type moderately doped Si. The shrinkage of the Si bandgap has been obtained by measuring the internal quantum efficiency in the near infrared spectrum ( hv = 1.00-1.25 eV) around the fundamental absorption edge. The results agree with previous optical measurements of bandgap narrowing in Si. It is postulated that this optically-determined bandgap narrowing is the rigid shrinkage of the forbidden gap due to many-body effects. The "device bandgap narrowing" obtained by measuring the pn product in bipolar devices leads to discrepant values because (i) the density of states in the conduction and valence band is modified due to the potential fluctuations originated in the variations in local impurity density, and (ii) the influence of Fermi-Dirac statistics.

  9. Effect of palady and cup feeding on premature neonates' weight gain and reaching full oral feeding time interval.

    PubMed

    Marofi, Maryam; Abedini, Fatemeh; Mohammadizadeh, Majid; Talakoub, Sedigheh

    2016-01-01

    Premature neonates' feeding is of great importance due to its effective role in their growth. These neonates should reach an independent oral nutrition stage before being discharged from the Neonatal Intensive care Unit. Therefore, the researcher decided to conduct a study on the effect of palady and cup feeding on premature neonates' weight gain and their reaching full oral feeding time interval. This is a clinical trial with a quantitative design conducted on 69 premature infants (gestational age between 29 and 32 weeks) who were assigned to cup (n = 34) and palady (n = 35) feeding groups through random allocation. The first feeding was administrated either by cup or palady method in each shift within seven sequential days (total of 21 cup and palady feedings). Then, the rest of feeding was administrated by gavage. Mean hospitalization time (cup = 39.01 and palady = 30.4; P < 0.001) and mean time interval to reach full oral feeding (cup = 33.7 and palady = 24.1; P < 0.001) were significantly lower in palady group compared to cup group. Mean weight changes of neonates 7 weeks after the intervention compared to those in the beginning of the intervention were significantly more in palady group compared to the cup group (cup = 146.7 and palady = 198.8; P < 0.001). The neonates in palady group reached full oral feeding earlier than those of cup group. Subjects' weight gain was also higher in palady group compared to the cup group. Premature neonates with over 30 weeks of gestational age and physiological stability can be fed by palady.

  10. Evaluation of the Effects of Light Intensity and Time Interval After the Start of Scotophase on the Female Flight Propensity of Asian Gypsy Moth (Lepidoptera: Erebidae).

    PubMed

    Chen, Fang; Shi, Juan; Keena, Melody

    2016-04-01

    Asian gypsy moth, Lymantria dispar L. (Lepidoptera: Erebidae), females are capable of flight, but little is known about what causes the variation in flight propensity that has been observed. The female flight propensity and capability of Asian gypsy moth from seven geographic populations (three from China, two from Russia, one from Japan, and one from Korea) were compared under all combinations of three light intensities (0.05, 0.10, and 0.40 lux) and during three time intervals after the start of scotophase. A total of 567 females were flight tested. Female flight propensity, time to initiate walking, fanning, and flying, and duration of fanning differed significantly among geographic populations. Females were less likely to voluntarily fly during the 0-1-h time interval after the start of scotophase than during the later time intervals (1-2 and 2-3 h), suggesting that the light intensity cue has to occur at the correct time after the expected start of scotophase for flight initiation. Light intensity did not significantly affect the proportion of females that voluntarily flew, but did impact the timing of the walking and fanning preflight behaviors. The interaction between light intensity and time interval after the start of scotophase had a significant effect on the proportion of females that fanned. The proportion of females with sustained flight capability varied among the populations evaluated. These results may aid in determining the risk of Asian gypsy moth dispersal, but further work is needed to assess other factors that play a role in flight propensity. Published by Oxford University Press on behalf of Entomological Society of America 2016. This work is written by US Government employees and is in the public domain in the US.

  11. The effects of narrow and elevated path walking on aperture crossing.

    PubMed

    Hackney, Amy L; Cinelli, Michael E; Denomme, Luke T; Frank, James S

    2015-06-01

    The study investigated the impact that action capabilities have on identifying possibilities for action, particularly how postural threat influences the passability of apertures. To do this, the ability to maintain balance was challenged by manipulating the level of postural threat while walking. First, participants walked along a 7m path and passed through two vertical obstacles spaced 1.1-1.5×the shoulder width apart during normal walking. Next, postural threat was manipulated by having participants complete the task either walking on a narrow, ground level path or on an elevated/narrow path. Despite a decrease in walking speed as well as an increase in trunk sway in both the narrow and elevated/narrow walking conditions, the passability of apertures was only affected when the consequence of instability was greatest. In the elevated/narrow walking condition, individuals maintained a larger critical point (rotated their shoulders for larger aperture widths) compared to normal walking. However, this effect was not observed for the narrow path walking suggesting that the level of postural threat was not enough to impose similar changes to the critical point. Therefore, it appears that manipulating action capabilities by increasing postural threat does indeed influence aperture crossing behavior, however the consequence associated with instability must be high before both gait characteristics and the critical point are affected. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Perfect narrow band absorber for sensing applications.

    PubMed

    Luo, Shiwen; Zhao, Jun; Zuo, Duluo; Wang, Xinbing

    2016-05-02

    We design and numerically investigate a perfect narrow band absorber based on a metal-metal-dielectric-metal structure which consists of periodic metallic nanoribbon arrays. The absorber presents an ultra narrow absorption band of 1.11 nm with a nearly perfect absorption of over 99.9% in the infrared region. For oblique incidence, the absorber shows an absorption more than 95% for a wide range of incident angles from 0 to 50°. Structure parameters to the influence of the performance are investigated. The structure shows high sensing performance with a high sensitivity of 1170 nm/RIU and a large figure of merit of 1054. The proposed structure has great potential as a biosensor.

  13. A Precise Visual Method for Narrow Butt Detection in Specular Reflection Workpiece Welding

    PubMed Central

    Zeng, Jinle; Chang, Baohua; Du, Dong; Hong, Yuxiang; Chang, Shuhe; Zou, Yirong

    2016-01-01

    During the complex path workpiece welding, it is important to keep the welding torch aligned with the groove center using a visual seam detection method, so that the deviation between the torch and the groove can be corrected automatically. However, when detecting the narrow butt of a specular reflection workpiece, the existing methods may fail because of the extremely small groove width and the poor imaging quality. This paper proposes a novel detection method to solve these issues. We design a uniform surface light source to get high signal-to-noise ratio images against the specular reflection effect, and a double-line laser light source is used to obtain the workpiece surface equation relative to the torch. Two light sources are switched on alternately and the camera is synchronized to capture images when each light is on; then the position and pose between the torch and the groove can be obtained nearly at the same time. Experimental results show that our method can detect the groove effectively and efficiently during the welding process. The image resolution is 12.5 μm and the processing time is less than 10 ms per frame. This indicates our method can be applied to real-time narrow butt detection during high-speed welding process. PMID:27649173

  14. A Precise Visual Method for Narrow Butt Detection in Specular Reflection Workpiece Welding.

    PubMed

    Zeng, Jinle; Chang, Baohua; Du, Dong; Hong, Yuxiang; Chang, Shuhe; Zou, Yirong

    2016-09-13

    During the complex path workpiece welding, it is important to keep the welding torch aligned with the groove center using a visual seam detection method, so that the deviation between the torch and the groove can be corrected automatically. However, when detecting the narrow butt of a specular reflection workpiece, the existing methods may fail because of the extremely small groove width and the poor imaging quality. This paper proposes a novel detection method to solve these issues. We design a uniform surface light source to get high signal-to-noise ratio images against the specular reflection effect, and a double-line laser light source is used to obtain the workpiece surface equation relative to the torch. Two light sources are switched on alternately and the camera is synchronized to capture images when each light is on; then the position and pose between the torch and the groove can be obtained nearly at the same time. Experimental results show that our method can detect the groove effectively and efficiently during the welding process. The image resolution is 12.5 μm and the processing time is less than 10 ms per frame. This indicates our method can be applied to real-time narrow butt detection during high-speed welding process.

  15. Distortion of time interval reproduction in an epileptic patient with a focal lesion in the right anterior insular/inferior frontal cortices.

    PubMed

    Monfort, Vincent; Pfeuty, Micha; Klein, Madelyne; Collé, Steffie; Brissart, Hélène; Jonas, Jacques; Maillard, Louis

    2014-11-01

    This case report on an epileptic patient suffering from a focal lesion at the junction of the right anterior insular cortex (AIC) and the adjacent inferior frontal cortex (IFC) provides the first evidence that damage to this brain region impairs temporal performance in a visual time reproduction task in which participants had to reproduce the presentation duration (3, 5 and 7s) of emotionally-neutral and -negative pictures. Strikingly, as compared to a group of healthy subjects, the AIC/IFC case considerably overestimated reproduction times despite normal variability. The effect was obtained in all duration and emotion conditions. Such a distortion in time reproduction was not observed in four other epileptic patients without insular or inferior frontal damage. Importantly, the absolute extent of temporal over-reproduction increased in proportion to the magnitude of the target durations, which concurs with the scalar property of interval timing, and points to an impairment of time-specific rather than of non temporal (such as motor) mechanisms. Our data suggest that the disability in temporal reproduction of the AIC/IFC case would result from a distorted memory representation of the encoded duration, occurring during the process of storage and/or of recovery from memory and leading to a deviation of the temporal judgment during the reproduction task. These findings support the recent proposal that the anterior insular/inferior frontal cortices would be involved in time interval representation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Polyp detection rates using magnification with narrow band imaging and white light.

    PubMed

    Gilani, Nooman; Stipho, Sally; Panetta, James D; Petre, Sorin; Young, Michele A; Ramirez, Francisco C

    2015-05-16

    To compare the yield of adenomas between narrow band imaging and white light when using high definition/magnification. This prospective, non-randomized comparative study was performed at the endoscopy unit of veteran affairs medical center in Phoenix, Arizona. Consecutive patients undergoing first average risk colorectal cancer screening colonoscopy were selected. Two experienced gastroenterologists performed all the procedures that were blinded to each other's findings. Demographic details were recorded. Data are presented as mean ± SEM. Proportional data were compared using the χ(2) test and means were compared using the Student's t test. Tandem colonoscopy was performed in a sequential and segmental fashion using one of 3 strategies: white light followed by narrow band imaging [Group A: white light (WL) → narrow band imaging (NBI)]; narrow band imaging followed by white light (Group B: NBI → WL) and, white light followed by white light (Group C: WL → WL). Detection rate of missed polyps and adenomas were evaluated in all three groups. Three hundred patients were studied (100 in each Group). Although the total time for the colonoscopy was similar in the 3 groups (23.8 ± 0.7, 22.2 ± 0.5 and 24.1 ± 0.7 min for Groups A, B and C, respectively), it reached statistical significance between Groups B and C (P < 0.05). The cecal intubation time in Groups B and C was longer than for Group A (6.5 ± 0.4 min and 6.5 ± 0.4 min vs 4.9 ± 0.3 min; P < 0.05). The withdrawal time for Groups A and C was longer than Group B (18.9 ± 0.7 min and 17.6 ± 0.6 min vs 15.7 ± 0.4 min; P < 0.05). Overall miss rate for polyps and adenomas detected in three groups during the second look was 18% and 17%, respectively (P = NS). Detection rate for polyps and adenomas after first look with white light was similar irrespective of the light used during the second look (WL → WL: 13.7% for polyps, 12.6% for adenomas; WL → NBI: 14.2% for polyps, 11.3% for adenomas). Miss rate of

  17. Overconfidence in Interval Estimates: What Does Expertise Buy You?

    ERIC Educational Resources Information Center

    McKenzie, Craig R. M.; Liersch, Michael J.; Yaniv, Ilan

    2008-01-01

    People's 90% subjective confidence intervals typically contain the true value about 50% of the time, indicating extreme overconfidence. Previous results have been mixed regarding whether experts are as overconfident as novices. Experiment 1 examined interval estimates from information technology (IT) professionals and UC San Diego (UCSD) students…

  18. A Vision-Aided 3D Path Teaching Method before Narrow Butt Joint Welding.

    PubMed

    Zeng, Jinle; Chang, Baohua; Du, Dong; Peng, Guodong; Chang, Shuhe; Hong, Yuxiang; Wang, Li; Shan, Jiguo

    2017-05-11

    For better welding quality, accurate path teaching for actuators must be achieved before welding. Due to machining errors, assembly errors, deformations, etc., the actual groove position may be different from the predetermined path. Therefore, it is significant to recognize the actual groove position using machine vision methods and perform an accurate path teaching process. However, during the teaching process of a narrow butt joint, the existing machine vision methods may fail because of poor adaptability, low resolution, and lack of 3D information. This paper proposes a 3D path teaching method for narrow butt joint welding. This method obtains two kinds of visual information nearly at the same time, namely 2D pixel coordinates of the groove in uniform lighting condition and 3D point cloud data of the workpiece surface in cross-line laser lighting condition. The 3D position and pose between the welding torch and groove can be calculated after information fusion. The image resolution can reach 12.5 μm. Experiments are carried out at an actuator speed of 2300 mm/min and groove width of less than 0.1 mm. The results show that this method is suitable for groove recognition before narrow butt joint welding and can be applied in path teaching fields of 3D complex components.

  19. Influence of the narrow {111} planes on axial and planar ion channeling.

    PubMed

    Motapothula, M; Dang, Z Y; Venkatesan, T; Breese, M B H; Rana, M A; Osman, A

    2012-05-11

    We report channeling patterns where clearly resolved effects of the narrow {111} planes are observed in axial and planar alignments for 2 MeV protons passing through a 55 nm [001] silicon membrane. At certain axes, such as <213> and <314>, the offset in atomic rows forming the narrow {111} planes results in shielding from the large potential at the wide {111} planes, producing a region of shallow, asymmetric potential from which axial channeling patterns have no plane of symmetry. At small tilts from such axes, different behavior is observed from the wide and narrow {111} planes. At planar alignment, distinctive channeling effects due to the narrow planes are observed. As a consequence of the shallow potential well at the narrow planes, incident protons suffer dechanneled trajectories which are excluded from channeling within the wide planes, resulting in an anomalously large scattered beam at {111} alignment.

  20. The Effects of Interval Duration on Temporal Tracking and Alternation Learning

    ERIC Educational Resources Information Center

    Ludvig, Elliot A.; Staddon, John E. R.

    2005-01-01

    On cyclic-interval reinforcement schedules, animals typically show a postreinforcement pause that is a function of the immediately preceding time interval ("temporal tracking"). Animals, however, do not track single-alternation schedules--when two different intervals are presented in strict alternation on successive trials. In this experiment,…

  1. Time Interval From Breast-Conserving Surgery to Breast Irradiation in Early Stage Node-Negative Breast Cancer: 17-Year Follow-Up Results and Patterns of Recurrence

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vujovic, Olga, E-mail: olga.vujovic@lhsc.on.ca; Yu, Edward; Cherian, Anil

    Purpose: A retrospectivechart review was conducted to determine whether the time interval from breast-conserving surgery to breast irradiation (surgery-radiation therapy interval) in early stage node-negative breast cancer had any detrimental effects on recurrence rates. Methods and Materials: There were 566 patients with T1 to T3, N0 breast cancer treated with breast-conserving surgery and breast irradiation and without adjuvant systemic treatment between 1985 and 1992. The surgery-to-radiation therapy intervals used for analysis were 0 to 8 weeks (201 patients), >8 to 12 weeks (233 patients), >12 to 16 weeks (91 patients), and >16 weeks (41 patients). Kaplan-Meier estimates of time to local recurrence, disease-free survival, distantmore » disease-free survival, cause-specific survival, and overall survival rates were calculated. Results: Median follow-up was 17.4 years. Patients in all 4 time intervals were similar in terms of characteristics and pathologic features. There were no statistically significant differences among the 4 time groups in local recurrence (P=.67) or disease-free survival (P=.82). The local recurrence rates at 5, 10, and 15 years were 4.9%, 11.5%, and 15.0%, respectively. The distant disease relapse rates at 5, 10, and 15 years were 10.6%, 15.4%, and 18.5%, respectively. The disease-free failure rates at 5, 10, and 15 years were 20%, 32.3%, and 39.8%, respectively. Cause-specific survival rates at 5, 10, and 15 years were 92%, 84.6%, and 79.8%, respectively. The overall survival rates at 5, 10, and 15 years were 89.3%, 79.2%, and 66.9%, respectively. Conclusions: Surgery-radiation therapy intervals up to 16 weeks from breast-conserving surgery are not associated with any increased risk of recurrence in early stage node-negative breast cancer. There is a steady local recurrence rate of 1% per year with adjuvant radiation alone.« less

  2. Comparison of the health-related quality of life in patients with narrow gastric tube and whole stomach reconstruction after oncologic esophagectomy: a prospective randomized study.

    PubMed

    Zhang, M; Wu, Q C; Li, Q; Jiang, Y J; Zhang, C; Chen, D

    2013-01-01

    To compare the health-related quality of life in patients with narrow gastric tube and whole stomach reconstructions after oncologic esophagectomy. In a prospective randomized single-center study from 2007 to 2008, 104 patients underwent esophagectomy for cancer. To assess health-related quality of life, the questionnaire (European Organization for Research and Treatment of Cancer Quality of Life Questionnaire Core 30 and the Oesophagus-Specific Quality of Life Questionnaire 18) was administered at 3 weeks, 6 months, 1 year, and 2 years after surgery. The perioperative complication rate was 26.9% in narrow gastric tube group and 48.1% in whole stomach group (P = 0.31). At the time of 3 weeks after surgery, the reflux and dyspnea scores were higher in whole stomach group than in narrow gastric tube group, which meant that the patients in whole stomach group suffered more severe problem. At the time of 6 months and 1 year after surgery, the reflux scores were lower in narrow gastric tube group than in whole stomach group, which revealed that there were less problems of reflux in the patients of narrow gastric tube group; meanwhile, the score of physical function scale in narrow gastric tube group was higher conversely, which suggested that the patients gain a better status in physical function. Nausea and vomiting is the only notable symptom that was worse in whole stomach group at the time of 2 years after surgery, which suggested that patients in whole stomach group suffered more severe nausea and vomiting. Narrow gastric tube reconstruction may be a good alternative choice for patients undergoing oncologic esophagectomy in view of better health-related quality of life after the surgery.

  3. Programming with Intervals

    NASA Astrophysics Data System (ADS)

    Matsakis, Nicholas D.; Gross, Thomas R.

    Intervals are a new, higher-level primitive for parallel programming with which programmers directly construct the program schedule. Programs using intervals can be statically analyzed to ensure that they do not deadlock or contain data races. In this paper, we demonstrate the flexibility of intervals by showing how to use them to emulate common parallel control-flow constructs like barriers and signals, as well as higher-level patterns such as bounded-buffer producer-consumer. We have implemented intervals as a publicly available library for Java and Scala.

  4. Narrow Angle movie

    NASA Technical Reports Server (NTRS)

    1999-01-01

    This brief three-frame movie of the Moon was made from three Cassini narrow-angle images as the spacecraft passed by the Moon on the way to its closest approach with Earth on August 17, 1999. The purpose of this particular set of images was to calibrate the spectral response of the narrow-angle camera and to test its 'on-chip summing mode' data compression technique in flight. From left to right, they show the Moon in the green, blue and ultraviolet regions of the spectrum in 40, 60 and 80 millisecond exposures, respectively. All three images have been scaled so that the brightness of Crisium basin, the dark circular region in the upper right, is the same in each image. The spatial scale in the blue and ultraviolet images is 1.4 miles per pixel (2.3 kilometers). The original scale in the green image (which was captured in the usual manner and then reduced in size by 2x2 pixel summing within the camera system) was 2.8 miles per pixel (4.6 kilometers). It has been enlarged for display to the same scale as the other two. The imaging data were processed and released by the Cassini Imaging Central Laboratory for Operations (CICLOPS) at the University of Arizona's Lunar and Planetary Laboratory, Tucson, AZ.

    Photo Credit: NASA/JPL/Cassini Imaging Team/University of Arizona

    Cassini, launched in 1997, is a joint mission of NASA, the European Space Agency and Italian Space Agency. The mission is managed by NASA's Jet Propulsion Laboratory, Pasadena, CA, for NASA's Office of Space Science, Washington DC. JPL is a division of the California Institute of Technology, Pasadena, CA.

  5. A new algorithm for segmentation of cardiac quiescent phases and cardiac time intervals using seismocardiography

    NASA Astrophysics Data System (ADS)

    Jafari Tadi, Mojtaba; Koivisto, Tero; Pänkäälä, Mikko; Paasio, Ari; Knuutila, Timo; Teräs, Mika; Hänninen, Pekka

    2015-03-01

    Systolic time intervals (STI) have significant diagnostic values for a clinical assessment of the left ventricle in adults. This study was conducted to explore the feasibility of using seismocardiography (SCG) to measure the systolic timings of the cardiac cycle accurately. An algorithm was developed for the automatic localization of the cardiac events (e.g. the opening and closing moments of the aortic and mitral valves). Synchronously acquired SCG and electrocardiography (ECG) enabled an accurate beat to beat estimation of the electromechanical systole (QS2), pre-ejection period (PEP) index and left ventricular ejection time (LVET) index. The performance of the algorithm was evaluated on a healthy test group with no evidence of cardiovascular disease (CVD). STI values were corrected based on Weissler's regression method in order to assess the correlation between the heart rate and STIs. One can see from the results that STIs correlate poorly with the heart rate (HR) on this test group. An algorithm was developed to visualize the quiescent phases of the cardiac cycle. A color map displaying the magnitude of SCG accelerations for multiple heartbeats visualizes the average cardiac motions and thereby helps to identify quiescent phases. High correlation between the heart rate and the duration of the cardiac quiescent phases was observed.

  6. Simultaneous determination of radionuclides separable into natural decay series by use of time-interval analysis.

    PubMed

    Hashimoto, Tetsuo; Sanada, Yukihisa; Uezu, Yasuhiro

    2004-05-01

    A delayed coincidence method, time-interval analysis (TIA), has been applied to successive alpha- alpha decay events on the millisecond time-scale. Such decay events are part of the (220)Rn-->(216)Po ( T(1/2) 145 ms) (Th-series) and (219)Rn-->(215)Po ( T(1/2) 1.78 ms) (Ac-series). By using TIA in addition to measurement of (226)Ra (U-series) from alpha-spectrometry by liquid scintillation counting (LSC), two natural decay series could be identified and separated. The TIA detection efficiency was improved by using the pulse-shape discrimination technique (PSD) to reject beta-pulses, by solvent extraction of Ra combined with simple chemical separation, and by purging the scintillation solution with dry N(2) gas. The U- and Th-series together with the Ac-series were determined, respectively, from alpha spectra and TIA carried out immediately after Ra-extraction. Using the (221)Fr-->(217)At ( T(1/2) 32.3 ms) decay process as a tracer, overall yields were estimated from application of TIA to the (225)Ra (Np-decay series) at the time of maximum growth. The present method has proven useful for simultaneous determination of three radioactive decay series in environmental samples.

  7. Rapid trench initiated recrystallization and stagnation in narrow Cu interconnect lines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O'Brien, Brendan B.; Rizzolo, Michael; Prestowitz, Luke C.

    2015-10-26

    Understanding and ultimately controlling the self-annealing of Cu in narrow interconnect lines has remained a top priority in order to continue down-scaling of back-end of the line interconnects. Recently, it was hypothesized that a bottom-up microstructural transformation process in narrow interconnect features competes with the surface-initiated overburden transformation. Here, a set of transmission electron microscopy images which captures the grain coarsening process in 48 nm lines in a time resolved manner is presented, supporting such a process. Grain size measurements taken from these images have demonstrated that the Cu microstructural transformation in 48 nm interconnect lines stagnates after only 1.5 h atmore » room temperature. This stubborn metastable structure remains stagnant, even after aggressive elevated temperature anneals, suggesting that a limited internal energy source such as dislocation content is driving the transformation. As indicated by the extremely low defect density found in 48 nm trenches, a rapid recrystallization process driven by annihilation of defects in the trenches appears to give way to a metastable microstructure in the trenches.« less

  8. Narrowing the Gap in Outcomes: Early Years (0-5 Years)

    ERIC Educational Resources Information Center

    Springate, Ian; Atkinson, Mary; Straw, Suzanne; Lamont, Emily; Grayson, Hilary

    2008-01-01

    This report was commissioned by the Local Government Association (LGA) to inform the Department for Children, Schools and Families (DCSF) and LGA work on "Narrowing the Gap." It focuses on early years' provision and presents findings from a review of the best evidence on narrowing the gap in outcomes across the five Every Child Matters…

  9. Very narrow band model calculations of atmospheric fluxes and cooling rates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bernstein, L.S.; Berk, A.; Acharya, P.K.

    1996-10-15

    A new very narrow band model (VNBM) approach has been developed and incorporated into the MODTRAN atmospheric transmittance-radiance code. The VNBM includes a computational spectral resolution of 1 cm{sup {minus}1}, a single-line Voigt equivalent width formalism that is based on the Rodgers-Williams approximation and accounts for the finite spectral width of the interval, explicit consideration of line tails, a statistical line overlap correction, a new sublayer integration approach that treats the effect of the sublayer temperature gradient on the path radiance, and the Curtis-Godson (CG) approximation for inhomogeneous paths. A modified procedure for determining the line density parameter 1/d ismore » introduced, which reduces its magnitude. This results in a partial correction of the VNBM tendency to overestimate the interval equivalent widths. The standard two parameter CG approximation is used for H{sub 2}O and CO{sub 2}, while the Goody three parameter CG approximation is used for O{sub 3}. Atmospheric flux and cooling rate predictions using a research version of MODTRAN, MODR, are presented for H{sub 2}O (with and without the continuum), CO{sub 2}, and O{sub 3} for several model atmospheres. The effect of doubling the CO{sub 2} concentration is also considered. These calculations are compared to line-by-line (LBL) model calculations using the AER, GLA, GFDL, and GISS codes. The MODR predictions fall within the spread of the LBL results. The effects of decreasing the band model spectral resolution are illustrated using CO{sub 2} cooling rate and flux calculations. 36 refs., 18 figs., 1 tab.« less

  10. Peripapillary Schisis in Glaucoma Patients With Narrow Angles and Increased Intraocular Pressure

    PubMed Central

    Kahook, Malik Y.; Noecker, Robert J.; Ishikawa, Hiroshi; Wollstein, Gadi; Kagemann, Larry; Wojtkowski, Maciej; Duker, Jay S.; Srinivasan, Vivek J.; Fujimoto, James G.; Schuman, Joel S.

    2007-01-01

    PURPOSE To describe two cases of peripapillary retinal schisis in patients with glaucoma without evidence of optic nerve pits, pseudopits, or X-linked retinoschisis. DESIGN Two observational case reports and literature review. METHODS Imaging of the peripapillary nerve fiber layer and schisis cavities was completed in two patients, and one patient was followed over time. RESULTS The first patient, diagnosed with narrow angle glaucoma, was noted to have peripapillary schisis in the right eye with matching changes on visual field and optical coherence tomographic (OCT) results. Follow-up examination revealed that the schisis disappeared in the right eye while appearing in the left. The findings were verified with high-speed ultra-high-resolution OCT performed in both eyes. The second case involved a patient with anatomically narrow angles, high intraocular pressure (IOP), and peripapillary schisis extending into the macula. CONCLUSIONS Peripapillary retinoschisis may represent a unique sequelae of intraocular fluctuations in patients with uncontrolled glaucoma. Further studies are needed to better understand this disease process. PMID:17386284

  11. The Influence of Interpregnancy Interval on Infant Mortality

    PubMed Central

    MCKINNEY, David; HOUSE, Melissa; CHEN, Aimin; MUGLIA, Louis; DEFRANCO, Emily

    2017-01-01

    Background In Ohio the infant mortality rate is above the national average and the black infant mortality rate is more than twice the white infant mortality rate. Having a short interpregnancy interval has been shown to correlate with preterm birth and low birth weight, but the effect of short interpregnancy interval on infant mortality is less well established. Objective To quantify the population impact of interpregnancy interval on the risk of infant mortality. Study Design This was a statewide population-based retrospective cohort study of all births (n=1,131,070) and infant mortalities (n=8,152) using linked Ohio birth and infant death records from 1/2007 through 9/2014. For this study we analyzed 5 interpregnancy interval categories: 0 to < 6 months, 6 to < 12 months, 12 to < 24 months, 24 to < 60 months, and ≥ 60 months. The primary outcome for this study was infant mortality. During the study period, 3701 infant mortalities were linked to a live birth certificate with an interpregnancy interval available. We calculated the frequency and relative risk (RR) of infant mortality for each interval compared to a referent interval of 12 to < 24 months. Stratified analyses by maternal race were also performed. Adjusted risks were estimated after accounting for statistically significant and biologically plausible confounding variables. Adjusted relative risk was utilized to calculate the attributable risk percent of short interpregnancy intervals on infant mortality. Results Short interpregnancy intervals were common in Ohio during the study period. 20.5% of all multiparous births followed an interval of < 12 months. The overall infant mortality rate during this time was 7.2 per 1000 live births (6.0 for white mothers and 13.1 for black mothers). Infant mortalities occurred more frequently for births that occurred following short intervals of 0 to < 6 months (9.2 per 1000) and 6 to < 12 months (7.1 per 1000) compared to 12 to < 24 months (5.6 per 1000), (p= <0

  12. Event- and interval-based measurement of stuttering: a review.

    PubMed

    Valente, Ana Rita S; Jesus, Luis M T; Hall, Andreia; Leahy, Margaret

    2015-01-01

    Event- and interval-based measurements are two different ways of computing frequency of stuttering. Interval-based methodology emerged as an alternative measure to overcome problems associated with reproducibility in the event-based methodology. No review has been made to study the effect of methodological factors in interval-based absolute reliability data or to compute the agreement between the two methodologies in terms of inter-judge, intra-judge and accuracy (i.e., correspondence between raters' scores and an established criterion). To provide a review related to reproducibility of event-based and time-interval measurement, and to verify the effect of methodological factors (training, experience, interval duration, sample presentation order and judgment conditions) on agreement of time-interval measurement; in addition, to determine if it is possible to quantify the agreement between the two methodologies The first two authors searched for articles on ERIC, MEDLINE, PubMed, B-on, CENTRAL and Dissertation Abstracts during January-February 2013 and retrieved 495 articles. Forty-eight articles were selected for review. Content tables were constructed with the main findings. Articles related to event-based measurements revealed values of inter- and intra-judge greater than 0.70 and agreement percentages beyond 80%. The articles related to time-interval measures revealed that, in general, judges with more experience with stuttering presented significantly higher levels of intra- and inter-judge agreement. Inter- and intra-judge values were beyond the references for high reproducibility values for both methodologies. Accuracy (regarding the closeness of raters' judgements with an established criterion), intra- and inter-judge agreement were higher for trained groups when compared with non-trained groups. Sample presentation order and audio/video conditions did not result in differences in inter- or intra-judge results. A duration of 5 s for an interval appears to be

  13. Spectrally narrowed lasing of a self-injection KrF excimer laser

    NASA Astrophysics Data System (ADS)

    Shimada, Yasuhiro; Wani, Koichi; Miki, Tadaaki; Kawahara, Hidehito; Mimasu, Mutsumi; Ogata, Yoshiro

    1990-08-01

    Spectrally nantwed lasing of a KrF excimer laser has teen ahieved by a self-injection technique using abeam splitter for power extraction aixi intravity etalons for spectral-narrowing. The laser cavity is divithi into an amplifying branch aix! a spectralnarrowing branch. The spectral bandwidth was narrowed to <3pm FWHM with air-sed etalons placed in the spectral-narrowing branch. A laser propagation model was intrOdUced for describing the laser intensity traveling in the laser cavity. The calculated intensityincident onthe intracavityetalons wassmaller thanthat in theconventional Fabry-Perotcavity withplane-parallel mirrors.

  14. Inconsistencies in Numerical Simulations of Dynamical Systems Using Interval Arithmetic

    NASA Astrophysics Data System (ADS)

    Nepomuceno, Erivelton G.; Peixoto, Márcia L. C.; Martins, Samir A. M.; Rodrigues, Heitor M.; Perc, Matjaž

    Over the past few decades, interval arithmetic has been attracting widespread interest from the scientific community. With the expansion of computing power, scientific computing is encountering a noteworthy shift from floating-point arithmetic toward increased use of interval arithmetic. Notwithstanding the significant reliability of interval arithmetic, this paper presents a theoretical inconsistency in a simulation of dynamical systems using a well-known implementation of arithmetic interval. We have observed that two natural interval extensions present an empty intersection during a finite time range, which is contrary to the fundamental theorem of interval analysis. We have proposed a procedure to at least partially overcome this problem, based on the union of the two generated pseudo-orbits. This paper also shows a successful case of interval arithmetic application in the reduction of interval width size on the simulation of discrete map. The implications of our findings on the reliability of scientific computing using interval arithmetic have been properly addressed using two numerical examples.

  15. Effect of selected water temperatures used in Mycoplasma gallisepticum vaccine reconstitution on titer at selected time intervals.

    PubMed

    Branton, S L; Leigh, S A; Roush, W B; Purswell, J L; Olanrewaju, H A; Collier, S D

    2008-06-01

    Numerous methods are currently used throughout the poultry industry for the administration of vaccines. Each utilizes water for vaccine reconstitution and/or administration, including two of the three commercially available live Mycoplasma gallisepticum (MG) vaccines. Selected water temperatures were used to reconstitute and/or dilute the three commercially available live MG vaccines. Water temperatures included 4 C, 22 C (room temperature), and 32 C, and titer (color change units) was recorded at four time intervals, at point of reconstitution (time 0), 15, 30, and 60 min postreconstitution of the vaccines (time periods 15, 30, and 60, respectively). Results for F strain MG (FMG) vaccine showed significant decreases in titer from time 0 to time 15 for the 22 C and 32 C water temperatures but no significant decrease for any time period for FMG reconstituted with 4 C water. For 6/85 strain MG no significant difference in titer was noted for any of four time periods within any of the three water temperatures. For ts-11 strain MG a significant decrease was observed in titer at each of the four postdilution time periods when diluted with 32 C water. There was no significant decrease in titer at any time period for ts-11 MG vaccine when diluted with either 4 C or 22 C water.

  16. Interval Exercise Therapy for Type 2 Diabetes.

    PubMed

    Hamasaki, Hidetaka

    2018-01-01

    Regular exercise improves glycemic control and reduces cardiovascular risk and mortality in patients with type 2 diabetes. Continuous moderate- to high-intensity exercise has been recommended to manage type 2 diabetes; however, only approximately 30% of diabetic patients achieve the recommended levels of physical activity. The reasons for not engaging in regular exercise vary; however, one of the common reasons is lack of time. Recently, the effectiveness of shortduration interval exercise such as high-intensity interval training and interval walking has been observed. Thus, the author aimed to summarize the current knowledge and discuss recent literature regarding the effects of interval exercise therapy in type 2 diabetes. The author searched the English literature on interval training and type 2 diabetes using Pub- Med. A total of 8 studies met the criteria. Interval exercise is feasible and effective in obtaining glycemic control in patients with type 2 diabetes. It may also improve body composition, insulin sensitivity, aerobic capacity, and oxidative stress more effectively than continuous exercise. As a novel exercise therapy, interval training appears to be effective in managing type 2 diabetes. However, the safety and efficacy of this exercise modality in patients with progressed diabetic complications or a history of cardiovascular disease and in extremely older individuals remain unknown. Additionally, there is considerable heterogeneity in exercise interventions (intensity and duration) between clinical studies. Further studies are needed. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  17. A narrow band pattern-matching model of vowel perception

    NASA Astrophysics Data System (ADS)

    Hillenbrand, James M.; Houde, Robert A.

    2003-02-01

    The purpose of this paper is to propose and evaluate a new model of vowel perception which assumes that vowel identity is recognized by a template-matching process involving the comparison of narrow band input spectra with a set of smoothed spectral-shape templates that are learned through ordinary exposure to speech. In the present simulation of this process, the input spectra are computed over a sufficiently long window to resolve individual harmonics of voiced speech. Prior to template creation and pattern matching, the narrow band spectra are amplitude equalized by a spectrum-level normalization process, and the information-bearing spectral peaks are enhanced by a ``flooring'' procedure that zeroes out spectral values below a threshold function consisting of a center-weighted running average of spectral amplitudes. Templates for each vowel category are created simply by averaging the narrow band spectra of like vowels spoken by a panel of talkers. In the present implementation, separate templates are used for men, women, and children. The pattern matching is implemented with a simple city-block distance measure given by the sum of the channel-by-channel differences between the narrow band input spectrum (level-equalized and floored) and each vowel template. Spectral movement is taken into account by computing the distance measure at several points throughout the course of the vowel. The input spectrum is assigned to the vowel template that results in the smallest difference accumulated over the sequence of spectral slices. The model was evaluated using a large database consisting of 12 vowels in /hVd/ context spoken by 45 men, 48 women, and 46 children. The narrow band model classified vowels in this database with a degree of accuracy (91.4%) approaching that of human listeners.

  18. Pigeons' Memory for Number of Events: Effects of Intertrial Interval and Delay Interval Illumination

    ERIC Educational Resources Information Center

    Hope, Chris; Santi, Angelo

    2004-01-01

    In Experiment 1, pigeons were trained at a 0-s baseline delay to discriminate sequences of light flashes (illumination of the feeder) that varied in number but not time (2f/4s and 8f/4s). During training, the intertrial interval was illuminated by the houselight for Group Light, but it was dark for Group Dark. Testing conducted with dark delay…

  19. Psychophysical basis for consonant musical intervals

    NASA Astrophysics Data System (ADS)

    Resnick, L.

    1981-06-01

    A suggestion is made to explain the acceptance of certain musical intervals as consonant and others as dissonant. The proposed explanation involves the relation between the time required to perceive a definite pitch and the period of a complex tone. If the former time is greater than the latter, the tone is consonant; otherwise it is dissonant. A quantitative examination leads to agreement with empirical data.

  20. An Intervention to Reduce the Time Interval Between Hospital Entry and Emergency Coronary Angiography in Patients with ST-Elevation Myocardial Infarction.

    PubMed

    Karkabi, Basheer; Jaffe, Ronen; Halon, David A; Merdler, Amnon; Khader, Nader; Rubinshtein, Ronen; Goldstein, Jacob; Zafrir, Barak; Zissman, Keren; Ben-Dov, Nissan; Gabrielly, Michael; Fuks, Alex; Shiran, Avinoam; Adawi, Salim; Hellman, Yaron; Shahla, Johny; Halabi, Salim; Flugelman, Moshe Y; Cohen, Shai; Bergman, Irina; Kassem, Sameer; Shapira, Chen

    2017-09-01

    Outcomes of patients with acute ST-elevation myocardial infarction (STEMI) are strongly correlated to the time interval from hospital entry to primary percutaneous coronary intervention (PPCI). Current guidelines recommend a door to balloon time of < 90 minutes. To reduce the time from hospital admission to PPCI and to increase the proportion of patients treated within 90 minutes. In March 2013 the authors launched a seven-component intervention program:  Direct patient evacuation by out-of-hospital emergency medical services to the coronary intensive care unit or catheterization laboratory Education program for the emergency department staff Dissemination of information regarding the urgency of the PPCI decision Activation of the catheterization team by a single phone call Reimbursement for transportation costs to on-call staff who use their own cars Improvement in the quality of medical records Investigation of failed cases and feedback. During the 14 months prior to the intervention, initiation of catheterization occurred within 90 minutes of hospital arrival in 88/133 patients(65%); during the 18 months following the start of the intervention, the rate was 181/200 (90%) (P < 0.01). The respective mean/median times to treatment were 126/67 minutes and 52/47 minutes (P < 0.01). Intervention also resulted in shortening of the time interval from hospital entry to PPCI on nights and weekends. Following implementation of a comprehensive intervention, the time from hospital admission to PPCI of STEMI patients shortened significantly, as did the proportion of patients treated within 90 minutes of hospital arrival.

  1. Interval Training.

    ERIC Educational Resources Information Center

    President's Council on Physical Fitness and Sports, Washington, DC.

    Regardless of the type of physical activity used, interval training is simply repeated periods of physical stress interspersed with recovery periods during which activity of a reduced intensity is performed. During the recovery periods, the individual usually keeps moving and does not completely recover before the next exercise interval (e.g.,…

  2. Orders on Intervals Over Partially Ordered Sets: Extending Allen's Algebra and Interval Graph Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zapata, Francisco; Kreinovich, Vladik; Joslyn, Cliff A.

    2013-08-01

    To make a decision, we need to compare the values of quantities. In many practical situations, we know the values with interval uncertainty. In such situations, we need to compare intervals. Allen’s algebra describes all possible relations between intervals on the real line, and ordering relations between such intervals are well studied. In this paper, we extend this description to intervals in an arbitrary partially ordered set (poset). In particular, we explicitly describe ordering relations between intervals that generalize relation between points. As auxiliary results, we provide a logical interpretation of the relation between intervals, and extend the results aboutmore » interval graphs to intervals over posets.« less

  3. The extremely narrow-caliber esophagus is a treatment-resistant subphenotype of eosinophilic esophagitis.

    PubMed

    Eluri, Swathi; Runge, Thomas M; Cotton, Cary C; Burk, Caitlin M; Wolf, W Asher; Woosley, John T; Shaheen, Nicholas J; Dellon, Evan S

    2016-06-01

    Some patients with eosinophilic esophagitis (EoE) have an extremely narrow esophagus, but the characteristics of this group have not been extensively described. We aimed to characterize the narrow-caliber phenotype of EoE, determine associated risk factors, and identify differences in treatment response in this subgroup of patients. This retrospective cohort study from 2001 to 2014 included subjects with a new diagnosis of EoE per consensus guidelines. Demographic, endoscopic, histologic, and treatment response data were extracted from medical records. An extremely narrow-caliber esophagus was defined when a neonatal endoscope was required to traverse the esophagus due to the inability to pass an adult endoscope. Patients with and without an extremely narrow-caliber esophagus were compared. Multivariable logistical regression was performed to assess treatment outcomes. Of 513 patients with EoE, 46 (9%) had an extremely narrow-caliber esophagus. These patients were older (33 vs 22 years; P < .01), had longer symptom duration (11 vs 3 years; P < .01), more dysphagia (98% vs 66%; P < .01), and food impactions (53% vs 31%; P < .01). Dilation was more common with extreme narrowing (69% vs 17%; P < .01). Patients with a narrow-caliber esophagus were more refractory to steroid treatment, with lower symptom (56% vs 85%), endoscopic (52% vs 76%), and histologic (33% vs 63%) responses (P < .01 for all), and these differences persisted after multivariate analysis. The extremely narrow-caliber esophagus is a more treatment-resistant subphenotype of EoE and is characterized by longer symptom duration and the need for multiple dilations. Recognition of an extremely narrow-caliber esophagus at diagnosis of EoE can provide important prognostic information. Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  4. How Does the Narrowing of Eligibility Criteria Affect Enrollment in Part C Early Intervention?

    ERIC Educational Resources Information Center

    Elbaum, Batya; Celimli-Aksoy, Seniz; Marshall, Jennifer T.; Berkovits, Michelle D.

    2017-01-01

    In recent years, many states have narrowed their eligibility criteria for participation in the IDEA Part C early intervention (EI) program for infants and toddlers with or at risk for developmental delays. However, there is scant research on the effects of such a policy change on the population of children served or on the timing of children's…

  5. 76 FR 60733 - Drawbridge Operation Regulations; Narrow Bay, Smith Point, NY

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-30

    ... Operation Regulations; Narrow Bay, Smith Point, NY AGENCY: Coast Guard, DHS. ACTION: Notice of temporary... deviation from the regulation governing the operation of the Smith Point Bridge, 6.1, across Narrow Bay, between Smith Point and Fire Island, New York. The deviation is necessary to facilitate bridge...

  6. Interval Graph Limits

    PubMed Central

    Diaconis, Persi; Holmes, Susan; Janson, Svante

    2015-01-01

    We work out a graph limit theory for dense interval graphs. The theory developed departs from the usual description of a graph limit as a symmetric function W (x, y) on the unit square, with x and y uniform on the interval (0, 1). Instead, we fix a W and change the underlying distribution of the coordinates x and y. We find choices such that our limits are continuous. Connections to random interval graphs are given, including some examples. We also show a continuity result for the chromatic number and clique number of interval graphs. Some results on uniqueness of the limit description are given for general graph limits. PMID:26405368

  7. Transition to complete synchronization and global intermittent synchronization in an array of time-delay systems.

    PubMed

    Suresh, R; Senthilkumar, D V; Lakshmanan, M; Kurths, J

    2012-07-01

    We report the nature of transitions from the nonsynchronous to a complete synchronization (CS) state in arrays of time-delay systems, where the systems are coupled with instantaneous diffusive coupling. We demonstrate that the transition to CS occurs distinctly for different coupling configurations. In particular, for unidirectional coupling, locally (microscopically) synchronization transition occurs in a very narrow range of coupling strength but for a global one (macroscopically) it occurs sequentially in a broad range of coupling strength preceded by an intermittent synchronization. On the other hand, in the case of mutual coupling, a very large value of coupling strength is required for local synchronization and, consequently, all the local subsystems synchronize immediately for the same value of the coupling strength and, hence, globally, synchronization also occurs in a narrow range of the coupling strength. In the transition regime, we observe a type of synchronization transition where long intervals of high-quality synchronization which are interrupted at irregular times by intermittent chaotic bursts simultaneously in all the systems and which we designate as global intermittent synchronization. We also relate our synchronization transition results to the above specific types using unstable periodic orbit theory. The above studies are carried out in a well-known piecewise linear time-delay system.

  8. Electronic structure descriptor for the discovery of narrow-band red-emitting phosphors

    DOE PAGES

    Wang, Zhenbin; Chu, Iek -Heng; Zhou, Fei; ...

    2016-05-09

    Narrow-band red-emitting phosphors are a critical component of phosphor-converted light-emitting diodes for highly efficient illumination-grade lighting. In this work, we report the discovery of a quantitative descriptor for narrow-band Eu 2+-activated emission identified through a comparison of the electronic structures of known narrow-band and broad-band phosphors. We find that a narrow emission bandwidth is characterized by a large splitting of more than 0.1 eV between the two highest Eu 2+ 4 f 7 bands. By incorporating this descriptor in a high-throughput first-principles screening of 2259 nitride compounds, we identify five promising new nitride hosts for Eu 2+-activated red-emitting phosphors thatmore » are predicted to exhibit good chemical stability, thermal quenching resistance, and quantum efficiency, as well as narrow-band emission. Lastly, our findings provide important insights into the emission characteristics of rare-earth activators in phosphor hosts and a general strategy to the discovery of phosphors with a desired emission peak and bandwidth.« less

  9. Electronic structure descriptor for the discovery of narrow-band red-emitting phosphors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Zhenbin; Chu, Iek -Heng; Zhou, Fei

    Narrow-band red-emitting phosphors are a critical component of phosphor-converted light-emitting diodes for highly efficient illumination-grade lighting. In this work, we report the discovery of a quantitative descriptor for narrow-band Eu 2+-activated emission identified through a comparison of the electronic structures of known narrow-band and broad-band phosphors. We find that a narrow emission bandwidth is characterized by a large splitting of more than 0.1 eV between the two highest Eu 2+ 4 f 7 bands. By incorporating this descriptor in a high-throughput first-principles screening of 2259 nitride compounds, we identify five promising new nitride hosts for Eu 2+-activated red-emitting phosphors thatmore » are predicted to exhibit good chemical stability, thermal quenching resistance, and quantum efficiency, as well as narrow-band emission. Lastly, our findings provide important insights into the emission characteristics of rare-earth activators in phosphor hosts and a general strategy to the discovery of phosphors with a desired emission peak and bandwidth.« less

  10. Multipoint Pacing versus conventional ICD in Patients with a Narrow QRS complex (MPP Narrow QRS trial): study protocol for a pilot randomized controlled trial.

    PubMed

    Gasparini, Maurizio; Galimberti, Paola; Bragato, Renato; Ghio, Stefano; Raineri, Claudia; Landolina, Maurizio; Chieffo, Enrico; Lunati, Maurizio; Mulargia, Ederina; Proclemer, Alessandro; Facchin, Domenico; Rordorf, Roberto; Vicentini, Alessandro; Marcantoni, Lina; Zanon, Francesco; Klersy, Catherine

    2016-12-03

    Despite an intensive search for predictors of the response to cardiac resynchronization therapy (CRT), the QRS duration remains the simplest and most robust predictor of a positive response. QRS duration of ≥ 130 ms is considered to be a prerequisite for CRT; however, some studies have shown that CRT may also be effective in heart failure (HF) patients with a narrow QRS (<130 ms). Since CRT can now be performed by pacing the left ventricle from multiple vectors via a single quadripolar lead, it is possible that multipoint pacing (MPP) might be effective in HF patients with a narrow QRS. This article reports the design of the MPP Narrow QRS trial, a prospective, randomized, multicenter, controlled feasibility study to investigate the efficacy of MPP using two LV pacing vectors in patients with a narrow QRS complex (100-130 ms). Fifty patients with a standard ICD indication will be enrolled and randomized (1:1) to either an MPP group or a Standard ICD group. All patients will undergo a low-dose dobutamine stress echo test and only those with contractile reserve will be included in the study and randomized. The primary endpoint will be the percentage of patients in each group that have reverse remodeling at 12 months, defined as a reduction in left ventricular end-systolic volume (LVESV) of >15% from the baseline. This feasibility study will determine whether MPP improves reverse remodeling, as compared with standard ICD, in HF patients who have a narrow QRS complex (100-130 ms). ClinicalTrials.gov, NCT02402816 . Registered on 25 March 2015.

  11. Mining of hospital laboratory information systems: a model study defining age- and gender-specific reference intervals and trajectories for plasma creatinine in a pediatric population.

    PubMed

    Søeby, Karen; Jensen, Peter Bjødstrup; Werge, Thomas; Sørensen, Steen

    2015-09-01

    The knowledge of physiological fluctuation and variation of even commonly used biochemical quantities in extreme age groups and during development is sparse. This challenges the clinical interpretation and utility of laboratory tests in these age groups. To explore the utility of hospital laboratory data as a source of information, we analyzed enzymatic plasma creatinine as a model analyte in two large pediatric hospital samples. Plasma creatinine measurements from 9700 children aged 0-18 years were obtained from hospital laboratory databases and partitioned into high-resolution gender- and age-groups. Normal probability plots were used to deduce parameters of the normal distributions from healthy creatinine values in the mixed hospital datasets. Furthermore, temporal trajectories were generated from repeated measurements to examine developmental patterns in periods of changing creatinine levels. Creatinine shows great age dependence from birth throughout childhood. We computed and replicated 95% reference intervals in narrow gender and age bins and showed them to be comparable to those determined in healthy population studies. We identified pronounced transitions in creatinine levels at different time points after birth and around the early teens, which challenges the establishment and usefulness of reference intervals in those age groups. The study documents that hospital laboratory data may inform on the developmental aspects of creatinine, on periods with pronounced heterogeneity and valid reference intervals. Furthermore, part of the heterogeneity in creatinine distribution is likely due to differences in biological and chronological age of children and should be considered when using age-specific reference intervals.

  12. SCDU (Spectral Calibration Development Unit) Testbed Narrow Angle Astrometric Performance

    NASA Technical Reports Server (NTRS)

    Wang, Xu; Goullioud, Renaud; Nemati, Bijan; Shao, Michael; Wehmeier, Udo J.; Weilert, Mark A.; Werne, Thomas A.; Wu, Janet P.; Zhai, Chengxing

    2010-01-01

    The most stringent astrometric performance requirements on NASA's SIM(Space Interferometer Mission)-Lite mission will come from the so-called Narrow-Angle (NA) observing scenario, aimed at finding Earth-like exoplanets, where the interferometer chops between the target star and several nearby reference stars multiple times over the course of a single visit. Previously, about 20 pm NA error with various shifts was reported. Since then, investigation has been under way to understand the mechanisms that give rise to these shifts. In this paper we report our findings, the adopted mitigation strategies, and the resulting testbed performance.

  13. Interpregnancy interval and risk of autistic disorder.

    PubMed

    Gunnes, Nina; Surén, Pål; Bresnahan, Michaeline; Hornig, Mady; Lie, Kari Kveim; Lipkin, W Ian; Magnus, Per; Nilsen, Roy Miodini; Reichborn-Kjennerud, Ted; Schjølberg, Synnve; Susser, Ezra Saul; Øyen, Anne-Siri; Stoltenberg, Camilla

    2013-11-01

    A recent California study reported increased risk of autistic disorder in children conceived within a year after the birth of a sibling. We assessed the association between interpregnancy interval and risk of autistic disorder using nationwide registry data on pairs of singleton full siblings born in Norway. We defined interpregnancy interval as the time from birth of the first-born child to conception of the second-born child in a sibship. The outcome of interest was autistic disorder in the second-born child. Analyses were restricted to sibships in which the second-born child was born in 1990-2004. Odds ratios (ORs) were estimated by fitting ordinary logistic models and logistic generalized additive models. The study sample included 223,476 singleton full-sibling pairs. In sibships with interpregnancy intervals <9 months, 0.25% of the second-born children had autistic disorder, compared with 0.13% in the reference category (≥ 36 months). For interpregnancy intervals shorter than 9 months, the adjusted OR of autistic disorder in the second-born child was 2.18 (95% confidence interval 1.42-3.26). The risk of autistic disorder in the second-born child was also increased for interpregnancy intervals of 9-11 months in the adjusted analysis (OR = 1.71 [95% CI = 1.07-2.64]). Consistent with a previous report from California, interpregnancy intervals shorter than 1 year were associated with increased risk of autistic disorder in the second-born child. A possible explanation is depletion of micronutrients in mothers with closely spaced pregnancies.

  14. Photon time-interval statistics applied to the analysis of laser heterodyne signal with photon counter

    NASA Astrophysics Data System (ADS)

    Liu, Lisheng; Zhang, Heyong; Guo, Jin; Zhao, Shuai; Wang, Tingfeng

    2012-08-01

    In this paper, we report a mathematical derivation of probability density function (PDF) of time-interval between two successive photoelectrons of the laser heterodyne signal, and give a confirmation of the theoretical result by both numerical simulation and an experiment. The PDF curve of the beat signal displays a series of fluctuations, the period and amplitude of which are respectively determined by the beat frequency and the mixing efficiency. The beat frequency is derived from the frequency of fluctuations accordingly when the PDF curve is measured. This frequency measurement method still works while the traditional Fast Fourier Transform (FFT) algorithm hardly derives the correct peak value of the beat frequency in the condition that we detect 80 MHz beat signal with 8 Mcps (counts per-second) photons count rate, and this indicates an advantage of the PDF method.

  15. Setting the Revisit Interval in Primary Care

    PubMed Central

    Schwartz, Lisa M; Woloshin, Steven; Wasson, John H; Renfrew, Roger A; Welch, H Gilbert

    1999-01-01

    OBJECTIVE Although longitudinal care constitutes the bulk of primary care, physicians receive little guidance on the fundamental question of how to time follow-up visits. We sought to identify important predictors of the revisit interval and to describe the variability in how physicians set these intervals when caring for patients with common medical conditions. DESIGN Cross-sectional survey of physicians performed at the end of office visits for consecutive patients with hypertension, angina, diabetes, or musculoskeletal pain. PARTICIPANTS/SETTING One hundred sixty-four patients under the care of 11 primary care physicians in the Dartmouth Primary Care Cooperative Research Network. MEASUREMENTS The main outcome measures were the variability in mean revisit intervals across physicians and the proportion of explained variance by potential determinants of revisit intervals. We assessed the relation between the revisit interval (dependent variable) and three groups of independent variables, patient characteristics (e.g., age, physician perception of patient health), identification of individual physician, and physician characterization of the visit (e.g., routine visit, visit requiring a change in management, or visit occurring on a “hectic” day), using multiple regression that accounted for the natural grouping of patients within physician. MAIN RESULTS Revisit intervals ranged from 1 week to over 1 year. The most common intervals were 12 and 16 weeks. Physicians’ perception of fair-poor health status and visits involving a change in management were most strongly related to shorter revisit intervals. In multivariate analyses, patient characteristics explained about 18% of the variance in revisit intervals, and adding identification of the individual provider doubled the explained variance to about 40%. Physician characterization of the visit increased explained variance to 57%. The average revisit interval adjusted for patient characteristics for each of the 11

  16. A Vision-Aided 3D Path Teaching Method before Narrow Butt Joint Welding

    PubMed Central

    Zeng, Jinle; Chang, Baohua; Du, Dong; Peng, Guodong; Chang, Shuhe; Hong, Yuxiang; Wang, Li; Shan, Jiguo

    2017-01-01

    For better welding quality, accurate path teaching for actuators must be achieved before welding. Due to machining errors, assembly errors, deformations, etc., the actual groove position may be different from the predetermined path. Therefore, it is significant to recognize the actual groove position using machine vision methods and perform an accurate path teaching process. However, during the teaching process of a narrow butt joint, the existing machine vision methods may fail because of poor adaptability, low resolution, and lack of 3D information. This paper proposes a 3D path teaching method for narrow butt joint welding. This method obtains two kinds of visual information nearly at the same time, namely 2D pixel coordinates of the groove in uniform lighting condition and 3D point cloud data of the workpiece surface in cross-line laser lighting condition. The 3D position and pose between the welding torch and groove can be calculated after information fusion. The image resolution can reach 12.5 μm. Experiments are carried out at an actuator speed of 2300 mm/min and groove width of less than 0.1 mm. The results show that this method is suitable for groove recognition before narrow butt joint welding and can be applied in path teaching fields of 3D complex components. PMID:28492481

  17. Narrow-band injection seeding of a terahertz frequency quantum cascade laser: Selection and suppression of longitudinal modes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nong, Hanond, E-mail: Nong.Hanond@rub.de; Markmann, Sergej; Hekmat, Negar

    2014-09-15

    A periodically poled lithium niobate (PPLN) crystal with multiple poling periods is used to generate tunable narrow-bandwidth THz pulses for injection seeding a quantum cascade laser (QCL). We demonstrate that longitudinal modes of the quantum cascade laser close to the gain maximum can be selected or suppressed according to the seed spectrum. The QCL emission spectra obtained by electro-optic sampling from the quantum cascade laser, in the most favorable case, shows high selectivity and amplification of the longitudinal modes that overlap the frequency of the narrow-band seed. Proper selection of the narrow-band THz seed from the PPLN crystal discretely tunesmore » the longitudinal mode emission of the quantum cascade laser. Moreover, the THz wave build-up within the laser cavity is studied as a function of the round-trip time. When the seed frequency is outside the maximum of the gain spectrum the laser emission shifts to the preferential longitudinal mode.« less

  18. Narrow-Band Applications of Communications Satellites.

    ERIC Educational Resources Information Center

    Cowlan, Bert; Horowitz, Andrew

    This paper attempts to describe the advantages of "narrow-band" applications of communications satellites for education. It begins by discussing the general controversy surrounding the use of satellites in education, by placing the concern within the larger context of the general debate over the uses of new technologies in education, and by…

  19. CHARACTERIZATION OF A NARROW SPECTRUM ANTIMICROBIAL THAT EXHIBITS SPECIFIC ACTIVITY AGAINST UROPATHOGENIC BACTERIA

    DTIC Science & Technology

    2017-08-28

    NARROW-SPECTRUM ANTIMICROBIAL THAT EXHIBITS SPECIFIC ACTIVITY AGAINST UROPATHOGENIC BACTERIA by Caitlin M. Barrows Courtney M. Cowell Jennifer...From - To) October 2015 – September 2016 4. TITLE AND SUBTITLE CHARACTERIZATION OF A NARROW-SPECTRUM ANTIMICROBIAL THAT EXHIBITS SPECIFIC ACTIVITY ...objective of the work described in this report is to identify a narrow-spectrum antimicrobial that exhibits targeted activity against uropathogenic

  20. Design, Construction, Demonstration and Delivery of an Automated Narrow Gap Welding System.

    DTIC Science & Technology

    1983-03-31

    evaluated on the Narrow Gap welding system. By using the combinational qas shielding assembly, it is now possible to reduce the gas flow rates to a value...AD-A145 496 DESIGN CONSTRUCTION DEMONSTRATION AND DE IVER OF AN AUTOMATED NARROW GAP WELDING SYSTEM(U) CRC AUTOMATIC WELDING CO HODSTON SX 31 MAR 83...STANDARDS-963 - A CRC REPORT NO. NAV A/W 7 0PHASE 3 REPORT ON SDESIGN, CONSTRUCTION, DEMONSTRATION AND DELIVERY OF AN AUTOMATED NARROW GAP WELDING

  1. Modified Confidence Intervals for the Mean of an Autoregressive Process.

    DTIC Science & Technology

    1985-08-01

    Validity of the method 45 3.6 Theorem 47 4 Derivation of corrections 48 Introduction 48 The zero order pivot 50 4.1 Algorithm 50 CONTENTS The first...of standard confidence intervals. There are several standard methods of setting confidence intervals in simulations, including the regener- ative... method , batch means, and time series methods . We-will focus-s on improved confidence intervals for the mean of an autoregressive process, and as such our

  2. Structure of an energetic narrow discrete arc

    NASA Technical Reports Server (NTRS)

    Mcfadden, J. P.; Carlson, C. W.; Boehm, M. H.

    1990-01-01

    Particle distributions, waves, dc electric fields, and magnetic fields were measured by two sounding rockets at altitudes of 950 and 430 km through an energetic (greater than 5 keV) narrow (about 10 km) stable discrete arc. Although the payloads' magnetic footprints were separated by only 50 km, differences in the arc's structure were observed including the spatial width, peak energy, and characteristic spectra. The energetic electron precipitation included both slowly varying isotropic fluxes that formed an inverted-V energy-time signature and rapidly varying field-aligned fluxes at or below the isotropic spectral peak. The isotropic precipitation had a flux discontinuity inside the arc indicating the arc was present on a boundary between two different magnetospheric plasmas. Dispersive and nondispersive bursts of field-aligned electrons were measured throughout the arc, appearing over broad energy ranges or as monoenergetic beams. Dispersive bursts gave variable source distances less than 8000 km. Plateauing of some of the most intense bursts suggests that waves stabilized these electrons. During the lower altitude arc crossing, the field-aligned component formed a separate inverted-V energy-time signature whose peak energy was half the isotropic peak energy.

  3. Polyp detection rates using magnification with narrow band imaging and white light

    PubMed Central

    Gilani, Nooman; Stipho, Sally; Panetta, James D; Petre, Sorin; Young, Michele A; Ramirez, Francisco C

    2015-01-01

    AIM: To compare the yield of adenomas between narrow band imaging and white light when using high definition/magnification. METHODS: This prospective, non-randomized comparative study was performed at the endoscopy unit of veteran affairs medical center in Phoenix, Arizona. Consecutive patients undergoing first average risk colorectal cancer screening colonoscopy were selected. Two experienced gastroenterologists performed all the procedures that were blinded to each other’s findings. Demographic details were recorded. Data are presented as mean ± SEM. Proportional data were compared using the χ2 test and means were compared using the Student’s t test. Tandem colonoscopy was performed in a sequential and segmental fashion using one of 3 strategies: white light followed by narrow band imaging [Group A: white light (WL) → narrow band imaging (NBI)]; narrow band imaging followed by white light (Group B: NBI → WL) and, white light followed by white light (Group C: WL → WL). Detection rate of missed polyps and adenomas were evaluated in all three groups. RESULTS: Three hundred patients were studied (100 in each Group). Although the total time for the colonoscopy was similar in the 3 groups (23.8 ± 0.7, 22.2 ± 0.5 and 24.1 ± 0.7 min for Groups A, B and C, respectively), it reached statistical significance between Groups B and C (P < 0.05). The cecal intubation time in Groups B and C was longer than for Group A (6.5 ± 0.4 min and 6.5 ± 0.4 min vs 4.9 ± 0.3 min; P < 0.05). The withdrawal time for Groups A and C was longer than Group B (18.9 ± 0.7 min and 17.6 ± 0.6 min vs 15.7 ± 0.4 min; P < 0.05). Overall miss rate for polyps and adenomas detected in three groups during the second look was 18% and 17%, respectively (P = NS). Detection rate for polyps and adenomas after first look with white light was similar irrespective of the light used during the second look (WL → WL: 13.7% for polyps, 12.6% for adenomas; WL → NBI: 14.2% for polyps, 11.3% for

  4. Time Intervals in Sequence Sampling, Not Data Modifications, Have a Major Impact on Estimates of HIV Escape Rates

    PubMed Central

    2018-01-01

    The ability of human immunodeficiency virus (HIV) to avoid recognition by humoral and cellular immunity (viral escape) is well-documented, but the strength of the immune response needed to cause such a viral escape remains poorly quantified. Several previous studies observed a more rapid escape of HIV from CD8 T cell responses in the acute phase of infection compared to chronic infection. The rate of HIV escape was estimated with the help of simple mathematical models, and results were interpreted to suggest that CD8 T cell responses causing escape in acute HIV infection may be more efficient at killing virus-infected cells than responses that cause escape in chronic infection, or alternatively, that early escapes occur in epitopes mutations in which there is minimal fitness cost to the virus. However, these conclusions were challenged on several grounds, including linkage and interference of multiple escape mutations due to a low population size and because of potential issues associated with modifying the data to estimate escape rates. Here we use a sampling method which does not require data modification to show that previous results on the decline of the viral escape rate with time since infection remain unchanged. However, using this method we also show that estimates of the escape rate are highly sensitive to the time interval between measurements, with longer intervals biasing estimates of the escape rate downwards. Our results thus suggest that data modifications for early and late escapes were not the primary reason for the observed decline in the escape rate with time since infection. However, longer sampling periods for escapes in chronic infection strongly influence estimates of the escape rate. More frequent sampling of viral sequences in chronic infection may improve our understanding of factors influencing the rate of HIV escape from CD8 T cell responses. PMID:29495443

  5. Time Intervals in Sequence Sampling, Not Data Modifications, Have a Major Impact on Estimates of HIV Escape Rates.

    PubMed

    Ganusov, Vitaly V

    2018-02-27

    The ability of human immunodeficiency virus (HIV) to avoid recognition by humoral and cellular immunity (viral escape) is well-documented, but the strength of the immune response needed to cause such a viral escape remains poorly quantified. Several previous studies observed a more rapid escape of HIV from CD8 T cell responses in the acute phase of infection compared to chronic infection. The rate of HIV escape was estimated with the help of simple mathematical models, and results were interpreted to suggest that CD8 T cell responses causing escape in acute HIV infection may be more efficient at killing virus-infected cells than responses that cause escape in chronic infection, or alternatively, that early escapes occur in epitopes mutations in which there is minimal fitness cost to the virus. However, these conclusions were challenged on several grounds, including linkage and interference of multiple escape mutations due to a low population size and because of potential issues associated with modifying the data to estimate escape rates. Here we use a sampling method which does not require data modification to show that previous results on the decline of the viral escape rate with time since infection remain unchanged. However, using this method we also show that estimates of the escape rate are highly sensitive to the time interval between measurements, with longer intervals biasing estimates of the escape rate downwards. Our results thus suggest that data modifications for early and late escapes were not the primary reason for the observed decline in the escape rate with time since infection. However, longer sampling periods for escapes in chronic infection strongly influence estimates of the escape rate. More frequent sampling of viral sequences in chronic infection may improve our understanding of factors influencing the rate of HIV escape from CD8 T cell responses.

  6. Narrow-line magneto-optical cooling and trapping of strongly magnetic atoms.

    PubMed

    Berglund, Andrew J; Hanssen, James L; McClelland, Jabez J

    2008-03-21

    Laser cooling on weak transitions is a useful technique for reaching ultracold temperatures in atoms with multiple valence electrons. However, for strongly magnetic atoms a conventional narrow-line magneto-optical trap (MOT) is destabilized by competition between optical and magnetic forces. We overcome this difficulty in Er by developing an unusual narrow-line MOT that balances optical and magnetic forces using laser light tuned to the blue side of a narrow (8 kHz) transition. The trap population is spin polarized with temperatures reaching below 2 muK. Our results constitute an alternative method for laser cooling on weak transitions, applicable to rare-earth-metal and metastable alkaline earth elements.

  7. 78 FR 23845 - Drawbridge Operation Regulations; Narrow Bay, Smith Point, NY

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-23

    ... Operation Regulations; Narrow Bay, Smith Point, NY AGENCY: Coast Guard, DHS. ACTION: Notice of temporary... deviation from the regulation governing the operation of the Smith Point Bridge, mile 6.1, across Narrow Bay, between Smith Point and Fire Island, New York. The deviation is necessary to facilitate the Smith Point...

  8. Ultra-narrow-linewidth Brillouin/erbium fiber laser

    NASA Astrophysics Data System (ADS)

    Chen, Mo; Wang, Chenyu; Wang, Jianfei; Luo, Hong; Meng, Zhou

    2018-02-01

    Ultra-narrow-linewidth lasers are of great interest in many applications, such as precise spectroscopy, optical communications, and sensors. Stimulated Brillouin scattering (SBS), as one of the main nonlinear effects in fibers, is capable of generating narrow-linewidth light emission. We establish a compact Brillouin/erbium fiber laser (BEFL) utilizing 4-m erbium-doped fiber as both the Brillouin gain and linear media. A 360-kHz-linewidth laser diode is injected into the cavity as the Brillouin pump (BP) light and generates Brillouin Stokes lasing light. Both of the phase noise of the BP and BEFL output are measured by a high-accuracy unbalanced Michelson interferometer. It is demonstrated that 53- dB phase noise reduction is achieved after the BP is transferred into Brillouin Stokes emission. The linewidth of the BEFL is indicated at Hz-range by both calculation and experiment.

  9. Variable-Interval Sequenced-Action Camera (VINSAC). Dissemination Document No. 1.

    ERIC Educational Resources Information Center

    Ward, Ted

    The 16 millimeter (mm) Variable-Interval Sequenced-Action Camera (VINSAC) is designed for inexpensive photographic recording of effective teacher instruction and use of instructional materials for teacher education and research purposes. The camera photographs single frames at preselected time intervals (.5 second to 20 seconds) which are…

  10. Chosen interval methods for solving linear interval systems with special type of matrix

    NASA Astrophysics Data System (ADS)

    Szyszka, Barbara

    2013-10-01

    The paper is devoted to chosen direct interval methods for solving linear interval systems with special type of matrix. This kind of matrix: band matrix with a parameter, from finite difference problem is obtained. Such linear systems occur while solving one dimensional wave equation (Partial Differential Equations of hyperbolic type) by using the central difference interval method of the second order. Interval methods are constructed so as the errors of method are enclosed in obtained results, therefore presented linear interval systems contain elements that determining the errors of difference method. The chosen direct algorithms have been applied for solving linear systems because they have no errors of method. All calculations were performed in floating-point interval arithmetic.

  11. A technique for production of nanocrystalline cellulose with a narrow size distribution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bai, Wen; Holbery, James D.; Li, Kaichang

    2009-02-01

    Nanocrystalline cellulose (NCC) was prepared by sulfuric acid hydrolysis of microcrystalline cellulose. A differential centrifugation technique was studied to obtain NCC whiskers with a narrow size distribution. It was shown that the volume of NCC in different fractions had an inverse relationship with relative centrifugal force (RCF). The length of NCC whiskers was also fractionized by differential RCF. The aspect ratio of NCC in different fractions had a relatively narrow range. This technique provides an easy way of producing NCC whiskers with a narrow size distribution.

  12. Ischemic Ventricular Tachycardia Presenting as a Narrow Complex Tachycardia

    PubMed Central

    Page, Stephen P; Watts, Troy; Yeo, Wee Tiong; Mehul, Dhinoja

    2014-01-01

    This report describes a patient presenting with a narrow complex tachycardia in the context of prior myocardial infarction and impaired ventricular function. Electrophysiological studies confirmed ventricular tachycardia and activation and entrainment mapping demonstrated a critical isthmus within an area of scar involving the His-Purkinje system accounting for the narrow QRS morphology. This very rare case shares some similarities with upper septal ventricular tachycardia seen in patients with structurally normal hearts, but to our knowledge has not been seen previously in patients with ischemic heart disease. PMID:25057222

  13. Adverse effects of prohibiting narrow provider networks.

    PubMed

    Howard, David H

    2014-08-14

    Many insurers participating in the new insurance exchanges are controlling costs by offering plans with narrow provider networks. Proposed regulations would promote network adequacy, but a pro-provider stance may not be inherently pro-consumer or even pro-patient.

  14. The Main Ethiopian Rift: a Narrow Rift in a Hot Craton?

    NASA Astrophysics Data System (ADS)

    Gashawbeza, E.; Keranen, K.; Klemperer, S.; Lawrence, J.

    2008-12-01

    The Main Ethiopian Rift (MER) is a classic example of a narrow rift, but a synthesis of our results from the EAGLE (Ethiopia-Afar Geoscientific Lithospheric Experiment Phase I broadband experiment) and from the EBSE experiment (Ethiopia Broadband Seismic Experiment) suggests the MER formed in thin, hot, weak continental lithosphere, in strong contrast with predictions of the Buck model of modes of continental lithospheric extension. Our joint inversion of receiver functions and Rayleigh-wave group velocities yields shear-wave velocities of the lowermost crust and uppermost mantle across the MER and the Ethiopian Plateau that are significantly lower than the equivalent velocities in the Eastern and Western branches of the East African Rift System. The very low shear-wave velocities, high electrical conductivity in the lower-crust, and high shear-wave splitting delay times beneath a very broad region of the MER and the Ethiopian Plateau indicate that the lower-crust is hot and likely contains partial melt. Our S-receiver function data demonstrate shallowing of the lithosphere-asthenosphere boundary from 90 km beneath the northwestern Ethiopian Plateau to 60 km beneath the MER. Although we lack good spatial resolution on the lithosphere-asthenosphere boundary, the region of thinned lithosphere may be intermediate in width between the narrow surface rift (< 100 km) and the broader zone of strain in the lower crust (~ 300 km). The MER developed as a narrow rift at the surface, localized along the Neoproterozoic suture that joined East and West Gondwana. However, a far broader of lower crust and uppermost mantle remains thermally weakened since the Oligocene formation of the flood basalts by the Afar plume head. If the lithosphere- asthenosphere boundary is indeed a strain marker then lithospheric mantle deformation is localized beneath the surface rift. The development of both the Eastern/Western branches of the East African Rift System to the south and of the MER in

  15. Modeling of the spectral evolution in a narrow-linewidth fiber amplifier

    NASA Astrophysics Data System (ADS)

    Liu, Wei; Kuang, Wenjun; Jiang, Man; Xu, Jiangming; Zhou, Pu; Liu, Zejin

    2016-03-01

    Efficient numerical modeling of the spectral evolution in a narrow-linewidth fiber amplifier is presented. By describing the seeds using a statistical model and simulating the amplification process through power balanced equations combined with the nonlinear Schrödinger equations, the spectral evolution of different seeds in the fiber amplifier can be evaluated accurately. The simulation results show that the output spectra are affected by the temporal stability of the seeds and the seeds with constant amplitude in time are beneficial to maintain the linewidth of the seed in the fiber amplifier.

  16. 1/f Noise in Bak-Tang-Wiesenfeld Models on Narrow Stripes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maslov, S.; Tang, C.; Zhang, Y.

    We report our findings of a 1/f power spectrum for the total amount of sand in directed and undirected Bak-Tang-Wiesenfeld models confined to narrow stripes and driven locally. The underlying mechanism for the 1/f noise in these systems is an exponentially long configuration memory giving rise to a very broad distribution of time scales. Both models are solved analytically with the help of an operator algebra to explicitly show the appearance of the long configuration memory. {copyright} {ital 1999} {ital The American Physical Society}

  17. Symptomatic versus inapparent outcome in repeat dengue virus infections is influenced by the time interval between infections and study year.

    PubMed

    Montoya, Magelda; Gresh, Lionel; Mercado, Juan Carlos; Williams, Katherine L; Vargas, Maria José; Gutierrez, Gamaliel; Kuan, Guillermina; Gordon, Aubree; Balmaseda, Angel; Harris, Eva

    2013-01-01

    Four dengue virus serotypes (DENV1-4) circulate globally, causing more human illness than any other arthropod-borne virus. Dengue can present as a range of clinical manifestations from undifferentiated fever to Dengue Fever to severe, life-threatening syndromes. However, most DENV infections are inapparent. Yet, little is known about determinants of inapparent versus symptomatic DENV infection outcome. Here, we analyzed over 2,000 DENV infections from 2004 to 2011 in a prospective pediatric cohort study in Managua, Nicaragua. Symptomatic cases were captured at the study health center, and paired healthy annual samples were examined on a yearly basis using serological methods to identify inapparent DENV infections. Overall, inapparent and symptomatic DENV infections were equally distributed by sex. The mean age of infection was 1.2 years higher for symptomatic DENV infections as compared to inapparent infections. Although inapparent versus symptomatic outcome did not differ by infection number (first, second or third/post-second DENV infections), substantial variation in the proportion of symptomatic DENV infections among all DENV infections was observed across study years. In participants with repeat DENV infections, the time interval between a first inapparent DENV infection and a second inapparent infection was significantly shorter than the interval between a first inapparent and a second symptomatic infection. This difference was not observed in subsequent infections. This result was confirmed using two different serological techniques that measure total anti-DENV antibodies and serotype-specific neutralizing antibodies, respectively. Taken together, these findings show that, in this study, age, study year and time interval between consecutive DENV infections influence inapparent versus symptomatic infection outcome, while sex and infection number had no significant effect. Moreover, these results suggest that the window of cross-protection induced by a first

  18. Magnetic Resonance Fingerprinting with short relaxation intervals.

    PubMed

    Amthor, Thomas; Doneva, Mariya; Koken, Peter; Sommer, Karsten; Meineke, Jakob; Börnert, Peter

    2017-09-01

    The aim of this study was to investigate a technique for improving the performance of Magnetic Resonance Fingerprinting (MRF) in repetitive sampling schemes, in particular for 3D MRF acquisition, by shortening relaxation intervals between MRF pulse train repetitions. A calculation method for MRF dictionaries adapted to short relaxation intervals and non-relaxed initial spin states is presented, based on the concept of stationary fingerprints. The method is applicable to many different k-space sampling schemes in 2D and 3D. For accuracy analysis, T 1 and T 2 values of a phantom are determined by single-slice Cartesian MRF for different relaxation intervals and are compared with quantitative reference measurements. The relevance of slice profile effects is also investigated in this case. To further illustrate the capabilities of the method, an application to in-vivo spiral 3D MRF measurements is demonstrated. The proposed computation method enables accurate parameter estimation even for the shortest relaxation intervals, as investigated for different sampling patterns in 2D and 3D. In 2D Cartesian measurements, we achieved a scan acceleration of more than a factor of two, while maintaining acceptable accuracy: The largest T 1 values of a sample set deviated from their reference values by 0.3% (longest relaxation interval) and 2.4% (shortest relaxation interval). The largest T 2 values showed systematic deviations of up to 10% for all relaxation intervals, which is discussed. The influence of slice profile effects for multislice acquisition is shown to become increasingly relevant for short relaxation intervals. In 3D spiral measurements, a scan time reduction of 36% was achieved, maintaining the quality of in-vivo T1 and T2 maps. Reducing the relaxation interval between MRF sequence repetitions using stationary fingerprint dictionaries is a feasible method to improve the scan efficiency of MRF sequences. The method enables fast implementations of 3D spatially

  19. Interval Estimation of Seismic Hazard Parameters

    NASA Astrophysics Data System (ADS)

    Orlecka-Sikora, Beata; Lasocki, Stanislaw

    2017-03-01

    The paper considers Poisson temporal occurrence of earthquakes and presents a way to integrate uncertainties of the estimates of mean activity rate and magnitude cumulative distribution function in the interval estimation of the most widely used seismic hazard functions, such as the exceedance probability and the mean return period. The proposed algorithm can be used either when the Gutenberg-Richter model of magnitude distribution is accepted or when the nonparametric estimation is in use. When the Gutenberg-Richter model of magnitude distribution is used the interval estimation of its parameters is based on the asymptotic normality of the maximum likelihood estimator. When the nonparametric kernel estimation of magnitude distribution is used, we propose the iterated bias corrected and accelerated method for interval estimation based on the smoothed bootstrap and second-order bootstrap samples. The changes resulted from the integrated approach in the interval estimation of the seismic hazard functions with respect to the approach, which neglects the uncertainty of the mean activity rate estimates have been studied using Monte Carlo simulations and two real dataset examples. The results indicate that the uncertainty of mean activity rate affects significantly the interval estimates of hazard functions only when the product of activity rate and the time period, for which the hazard is estimated, is no more than 5.0. When this product becomes greater than 5.0, the impact of the uncertainty of cumulative distribution function of magnitude dominates the impact of the uncertainty of mean activity rate in the aggregated uncertainty of the hazard functions. Following, the interval estimates with and without inclusion of the uncertainty of mean activity rate converge. The presented algorithm is generic and can be applied also to capture the propagation of uncertainty of estimates, which are parameters of a multiparameter function, onto this function.

  20. The optimized V-V interval determined by interventricular conduction times versus invasive measurement by LVdP/dtMAX.

    PubMed

    van Gelder, Berry M; Meijer, Albert; Bracke, Frank A

    2008-09-01

    We compared the calculated optimal V-V interval derived from intracardiac electrograms (IEGM) with the optimized V-V interval determined by invasive measurement of LVdP/dt(MAX). Thirty-two patients with heart failure (six females, ages 68 +/- 7.8 years) had a CRT device implanted. After implantation of the atrial, right and a left ventricular lead, the optimal V-V interval was calculated using the QuickOpt formula (St. Jude Medical, Sylmar, CA, USA) applied to the respective IEGM recordings (V-V(IEGM)), and also determined by invasive measurement of LVdP/dt(MAX) (V-V(dP/dt)). The optimal V-V(IEGM) and V-V(dP/dt) intervals were 52.7 +/- 18 ms and 24.0 +/- 33 ms, respectively (P = 0.017), without correlation between the two. The baseline LVdP/dt(MAX) was 748 +/- 191 mmHg/s. The mean value of LVdP/dt(MAX) at invasive optimization was 947 +/- 198 mmHg/s, and at the calculated optimal V-V(IEGM) interval 920 +/- 191 mmHg/s (P < 0.0001). In spite of this significant difference, there was a good correlation between both methods (R = 0.991, P < 0.0001). However, a similarly good correlation existed between the maximum value of LVdP/dt(MAX) and LVdP/dt(MAX) at a fixed V-V interval of 0 ms (R = 0.993, P < 0.0001), or LVdP/dt(MAX) at a randomly selected V-V interval between 0 and +80 ms (R = 0.991, P < 0.0001). Optimizing the V-V interval with the IEGM method does not yield better hemodynamic results than simultaneous BiV pacing. Although a good correlation between LVdP/dt(MAX) determined with V-V(IEGM) and V-V(dP/dt) can be constructed, there is no correlation with the optimal settings of V-V interval in the individual patient.

  1. Value of intracochlear electrically evoked auditory brainstem response after cochlear implantation in patients with narrow internal auditory canal.

    PubMed

    Song, Mee Hyun; Bae, Mi Ran; Kim, Hee Nam; Lee, Won-Sang; Yang, Won Sun; Choi, Jae Young

    2010-08-01

    Cochlear implantation in patients with narrow internal auditory canal (IAC) can result in variable outcomes; however, preoperative evaluations have limitations in accurately predicting outcomes. In this study, we analyzed the outcomes of cochlear implantation in patients with narrow IAC and correlated the intracochlear electrically evoked auditory brainstem response (EABR) findings to postoperative performance to determine the prognostic significance of intracochlear EABR. Retrospective case series at a tertiary hospital. Thirteen profoundly deaf patients with narrow IAC who received cochlear implantation from 2002 to 2008 were included in this study. Postoperative performance was evaluated after at least 12 months of follow-up, and postoperative intracochlear EABR was measured to determine its correlation with outcome. The clinical significance of electrically evoked compound action potential (ECAP) was also analyzed. Patients with narrow IAC showed postoperative auditory performances ranging from CAP 0 to 4 after cochlear implantation. Intracochlear EABR measured postoperatively demonstrated prognostic value in the prediction of long-term outcomes, whereas ECAP measurements failed to show a significant correlation with outcome. Consistent with the advantages of intracochlear EABR over extracochlear EABR, this study demonstrates that intracochlear EABR has prognostic significance in predicting long-term outcomes in patients with narrow IAC. Intracochlear EABR measured either intraoperatively or in the early postoperative period may play an important role in deciding whether to continue with auditory rehabilitation using a cochlear implant or to switch to an auditory brainstem implant so as not to miss the optimal timing for language development.

  2. Assessing the Utility of Compound Trait Estimates of Narrow Personality Traits.

    PubMed

    Credé, Marcus; Harms, Peter D; Blacksmith, Nikki; Wood, Dustin

    2016-01-01

    It has been argued that approximations of narrow traits can be made through linear combinations of broad traits such as the Big Five personality traits. Indeed, Hough and Ones ( 2001 ) used a qualitative analysis of scale content to arrive at a taxonomy of how Big Five traits might be combined to approximate various narrow traits. However, the utility of such compound trait approximations has yet to be established beyond specific cases such as integrity and customer service orientation. Using data from the Eugene-Springfield Community Sample (Goldberg, 2008 ), we explore the ability of linear composites of scores on Big Five traits to approximate scores on 127 narrow trait measures from 5 well-known non-Big-Five omnibus measures of personality. Our findings indicate that individuals' standing on more than 30 narrow traits can be well estimated from 3 different types of linear composites of scores on Big Five traits without a substantial sacrifice in criterion validity. We discuss theoretical accounts for why such relationships exist as well as the theoretical and practical implications of these findings for researchers and practitioners.

  3. Grassy Narrows Reserve: Mercury Pollution, Social Disruption, and Natural Resources: A Question of Autonomy.

    ERIC Educational Resources Information Center

    Vecsey, Christopher

    1987-01-01

    Presents chronological socio-economic account of Grassy Narrows Reserve, focusing on the 1962-1970 mercury pollution that poisoned the reserve's river system and on resulting negotiations between the Ojibway people of Grassy Narrows, the government, and the polluting company. Examines the question of Grassy Narrows people gaining autonomy over the…

  4. Maximum likelihood estimation for semiparametric transformation models with interval-censored data

    PubMed Central

    Mao, Lu; Lin, D. Y.

    2016-01-01

    Abstract Interval censoring arises frequently in clinical, epidemiological, financial and sociological studies, where the event or failure of interest is known only to occur within an interval induced by periodic monitoring. We formulate the effects of potentially time-dependent covariates on the interval-censored failure time through a broad class of semiparametric transformation models that encompasses proportional hazards and proportional odds models. We consider nonparametric maximum likelihood estimation for this class of models with an arbitrary number of monitoring times for each subject. We devise an EM-type algorithm that converges stably, even in the presence of time-dependent covariates, and show that the estimators for the regression parameters are consistent, asymptotically normal, and asymptotically efficient with an easily estimated covariance matrix. Finally, we demonstrate the performance of our procedures through simulation studies and application to an HIV/AIDS study conducted in Thailand. PMID:27279656

  5. Einstein-Podolsky-Rosen Entanglement of Narrow-Band Photons from Cold Atoms.

    PubMed

    Lee, Jong-Chan; Park, Kwang-Kyoon; Zhao, Tian-Ming; Kim, Yoon-Ho

    2016-12-16

    Einstein-Podolsky-Rosen (EPR) entanglement introduced in 1935 deals with two particles that are entangled in their positions and momenta. Here we report the first experimental demonstration of EPR position-momentum entanglement of narrow-band photon pairs generated from cold atoms. By using two-photon quantum ghost imaging and ghost interference, we demonstrate explicitly that the narrow-band photon pairs violate the separability criterion, confirming EPR entanglement. We further demonstrate continuous variable EPR steering for positions and momenta of the two photons. Our new source of EPR-entangled narrow-band photons is expected to play an essential role in spatially multiplexed quantum information processing, such as, storage of quantum correlated images, quantum interface involving hyperentangled photons, etc.

  6. Einstein-Podolsky-Rosen Entanglement of Narrow-Band Photons from Cold Atoms

    NASA Astrophysics Data System (ADS)

    Lee, Jong-Chan; Park, Kwang-Kyoon; Zhao, Tian-Ming; Kim, Yoon-Ho

    2016-12-01

    Einstein-Podolsky-Rosen (EPR) entanglement introduced in 1935 deals with two particles that are entangled in their positions and momenta. Here we report the first experimental demonstration of EPR position-momentum entanglement of narrow-band photon pairs generated from cold atoms. By using two-photon quantum ghost imaging and ghost interference, we demonstrate explicitly that the narrow-band photon pairs violate the separability criterion, confirming EPR entanglement. We further demonstrate continuous variable EPR steering for positions and momenta of the two photons. Our new source of EPR-entangled narrow-band photons is expected to play an essential role in spatially multiplexed quantum information processing, such as, storage of quantum correlated images, quantum interface involving hyperentangled photons, etc.

  7. Visualizing single molecules interacting with nuclear pore complexes by narrow-field epifluorescence microscopy

    PubMed Central

    Yang, Weidong; Musser, Siegfried M.

    2008-01-01

    The utility of single molecule fluorescence (SMF) for understanding biological reactions has been amply demonstrated by a diverse series of studies over the last decade. In large part, the molecules of interest have been limited to those within a small focal volume or near a surface to achieve the high sensitivity required for detecting the inherently weak signals arising from individual molecules. Consequently, the investigation of molecular behavior with high time and spatial resolution deep within cells using SMF has remained challenging. Recently, we demonstrated that narrow-field epifluorescence microscopy allows visualization of nucleocytoplasmic transport at the single cargo level. We describe here the methodological approach that yields 2 ms and ∼15 nm resolution for a stationary particle. The spatial resolution for a mobile particle is inherently worse, and depends on how fast the particle is moving. The signal-to-noise ratio is sufficiently high to directly measure the time a single cargo molecule spends interacting with the nuclear pore complex. Particle tracking analysis revealed that cargo molecules randomly diffuse within the nuclear pore complex, exiting as a result of a single rate-limiting step. We expect that narrow-field epifluorescence microscopy will be useful for elucidating other binding and trafficking events within cells. PMID:16879979

  8. Statistical evaluation of time-dependent metabolite concentrations: estimation of post-mortem intervals based on in situ 1H-MRS of the brain.

    PubMed

    Scheurer, Eva; Ith, Michael; Dietrich, Daniel; Kreis, Roland; Hüsler, Jürg; Dirnhofer, Richard; Boesch, Chris

    2005-05-01

    Knowledge of the time interval from death (post-mortem interval, PMI) has an enormous legal, criminological and psychological impact. Aiming to find an objective method for the determination of PMIs in forensic medicine, 1H-MR spectroscopy (1H-MRS) was used in a sheep head model to follow changes in brain metabolite concentrations after death. Following the characterization of newly observed metabolites (Ith et al., Magn. Reson. Med. 2002; 5: 915-920), the full set of acquired spectra was analyzed statistically to provide a quantitative estimation of PMIs with their respective confidence limits. In a first step, analytical mathematical functions are proposed to describe the time courses of 10 metabolites in the decomposing brain up to 3 weeks post-mortem. Subsequently, the inverted functions are used to predict PMIs based on the measured metabolite concentrations. Individual PMIs calculated from five different metabolites are then pooled, being weighted by their inverse variances. The predicted PMIs from all individual examinations in the sheep model are compared with known true times. In addition, four human cases with forensically estimated PMIs are compared with predictions based on single in situ MRS measurements. Interpretation of the individual sheep examinations gave a good correlation up to 250 h post-mortem, demonstrating that the predicted PMIs are consistent with the data used to generate the model. Comparison of the estimated PMIs with the forensically determined PMIs in the four human cases shows an adequate correlation. Current PMI estimations based on forensic methods typically suffer from uncertainties in the order of days to weeks without mathematically defined confidence information. In turn, a single 1H-MRS measurement of brain tissue in situ results in PMIs with defined and favorable confidence intervals in the range of hours, thus offering a quantitative and objective method for the determination of PMIs. Copyright 2004 John Wiley & Sons, Ltd.

  9. Administration of the Phosphodiesterase Type 4 Inhibitor Rolipram into the Amygdala at a Specific Time Interval after Learning Increases Recognition Memory Persistence

    ERIC Educational Resources Information Center

    Werenicz, Aline; Christoff, Raissa R.; Blank, Martina; Jobim, Paulo F. C.; Pedroso, Thiago R.; Reolon, Gustavo K.; Schroder, Nadja; Roesler, Rafael

    2012-01-01

    Here we show that administration of the phosphodiesterase type 4 (PDE4) inhibitor rolipram into the basolateral complex of the amygdala (BLA) at a specific time interval after training enhances memory consolidation and induces memory persistence for novel object recognition (NOR) in rats. Intra-BLA infusion of rolipram immediately, 1.5 h, or 6 h…

  10. Preventive care and recall intervals. Targeting of services in child dental care in Norway.

    PubMed

    Wang, N J; Aspelund, G Ø

    2010-03-01

    Skewed caries distribution has made interesting the use of a high risk strategy in child dental services. The purpose of this study was to describe the preventive dental care given and the recall intervals used for children and adolescents in a low caries risk population, and to study how the time spent for preventive care and the length of intervals were associated with characteristics of the children and factors related to care delivery. Time spent for and type of preventive care, recall intervals, oral health and health behaviour of children and adolescents three to 18 years of age (n = 576) and the preventive services delivered were registered at routine dental examinations in the public dental services. The time used for preventive dental care was on average 22% of the total time used in a course of treatment (7.3 of 33.4 minutes). Less than 15% of the variation in time spent for prevention was explained by oral health, oral health behaviours and other characteristics of the children and the service delivery. The mean (SD) recall intervals were 15.4 (4.6) months and 55% of the children were given intervals equal to or longer than 18 months. Approximately 30% of the variation in the length of the recall intervals was explained by characteristics of the child and the service delivery. The time used for preventive dental care of children in a low risk population was standardized, while the recall intervals to a certain extent were individualized according to dental health and dental health behaviour.

  11. Turboprop and rotary-wing aircraft flight parameter estimation using both narrow-band and broadband passive acoustic signal-processing methods.

    PubMed

    Ferguson, B G; Lo, K W

    2000-10-01

    Flight parameter estimation methods for an airborne acoustic source can be divided into two categories, depending on whether the narrow-band lines or the broadband component of the received signal spectrum is processed to estimate the flight parameters. This paper provides a common framework for the formulation and test of two flight parameter estimation methods: one narrow band, the other broadband. The performances of the two methods are evaluated by applying them to the same acoustic data set, which is recorded by a planar array of passive acoustic sensors during multiple transits of a turboprop fixed-wing aircraft and two types of rotary-wing aircraft. The narrow-band method, which is based on a kinematic model that assumes the source travels in a straight line at constant speed and altitude, requires time-frequency analysis of the acoustic signal received by a single sensor during each aircraft transit. The broadband method is based on the same kinematic model, but requires observing the temporal variation of the differential time of arrival of the acoustic signal at each pair of sensors that comprises the planar array. Generalized cross correlation of each pair of sensor outputs using a cross-spectral phase transform prefilter provides instantaneous estimates of the differential times of arrival of the signal as the acoustic wavefront traverses the array.

  12. Foam relaxation in fractures and narrow channels

    NASA Astrophysics Data System (ADS)

    Lai, Ching-Yao; Rallabandi, Bhargav; Perazzo, Antonio; Stone, Howard A.

    2017-11-01

    Various applications, from foam manufacturing to hydraulic fracturing with foams, involve pressure-driven flow of foams in narrow channels. We report a combined experimental and theoretical study of this problem accounting for the compressible nature of the foam. In particular, in our experiments the foam is initially compressed in one channel and then upon flow into a second channel the compressed foam relaxes as it moves. A plug flow is observed in the tube and the pressure at the entrance of the tube is higher than the exit. We measure the volume collected at the exit of the tube, V, as a function of injection flow rate, tube length and diameter. Two scaling behaviors for V as a function of time are observed depending on whether foam compression is important or not. Our work may relate to foam fracturing, which saves water usage in hydraulic fracturing, more efficient enhanced oil recovery via foam injection, and various materials manufacturing processes involving pressure-driven flow foams.

  13. Cure rate model with interval censored data.

    PubMed

    Kim, Yang-Jin; Jhun, Myoungshic

    2008-01-15

    In cancer trials, a significant fraction of patients can be cured, that is, the disease is completely eliminated, so that it never recurs. In general, treatments are developed to both increase the patients' chances of being cured and prolong the survival time among non-cured patients. A cure rate model represents a combination of cure fraction and survival model, and can be applied to many clinical studies over several types of cancer. In this article, the cure rate model is considered in the interval censored data composed of two time points, which include the event time of interest. Interval censored data commonly occur in the studies of diseases that often progress without symptoms, requiring clinical evaluation for detection (Encyclopedia of Biostatistics. Wiley: New York, 1998; 2090-2095). In our study, an approximate likelihood approach suggested by Goetghebeur and Ryan (Biometrics 2000; 56:1139-1144) is used to derive the likelihood in interval censored data. In addition, a frailty model is introduced to characterize the association between the cure fraction and survival model. In particular, the positive association between the cure fraction and the survival time is incorporated by imposing a common normal frailty effect. The EM algorithm is used to estimate parameters and a multiple imputation based on the profile likelihood is adopted for variance estimation. The approach is applied to the smoking cessation study in which the event of interest is a smoking relapse and several covariates including an intensive care treatment are evaluated to be effective for both the occurrence of relapse and the non-smoking duration. Copyright (c) 2007 John Wiley & Sons, Ltd.

  14. New Madrid seismic zone recurrence intervals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schweig, E.S.; Ellis, M.A.

    1993-03-01

    Frequency-magnitude relations in the New Madrid seismic zone suggest that great earthquakes should occur every 700--1,200 yrs, implying relatively high strain rates. These estimates are supported by some geological and GPS results. Recurrence intervals of this order should have produced about 50 km of strike-slip offset since Miocene time. No subsurface evidence for such large displacements is known within the seismic zone. Moreover, the irregular fault pattern forming a compressive step that one sees today is not compatible with large displacements. There are at least three possible interpretations of the observations of short recurrence intervals and high strain rates, butmore » apparently youthful fault geometry and lack of major post-Miocene deformation. One is that the seismological and geodetic evidence are misleading. A second possibility is that activity in the region is cyclic. That is, the geological and geodetic observations that suggest relatively short recurrence intervals reflect a time of high, but geologically temporary, pore-fluid pressure. Zoback and Zoback have suggested such a model for intraplate seismicity in general. Alternatively, the New Madrid seismic zone is geologically young feature that has been active for only the last few tens of thousands of years. In support of this, observe an irregular fault geometry associated with a unstable compressive step, a series of en echelon and discontinuous lineaments that may define the position of a youthful linking fault, and the general absence of significant post-Eocene faulting or topography.« less

  15. CT demonstration of pharyngeal narrowing in adult obstructive sleep apnea

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bohlman, M.E.; Haponik, E.F.; Smith, P.L.

    Sleep apnea is a major cause of daytime hypersomnolence. Among the proposed etiologies, focal obstruction of the airways at the level of the pharynx has been suggested but not proven. Using computed tomography, the cross-sectional area of the airway can be readily assessed. Thirty-three adults with clinically proven sleep apnea and 12 normal adults underwent systematic computed tomography of the neck. Significant airway narrowing was demonstrated in all the patients with obstructive sleep apnea, whereas no such narrowing was seen in the controls. In 11, the narrowing was at a single level, whereas in 22 patients two or more levelsmore » were affected. This study has shown that a structurally abnormal airway may serve as an anatomic substrate for the development of sleep apnea. On the basis of this evidence, uvulopalatopharyngoplasty has been performed in two patients with relief of symptoms in one.« less

  16. Efficacy of a Novel Narrow Knife with Water Jet Function for Colorectal Endoscopic Submucosal Dissection.

    PubMed

    Yoshida, Naohisa; Toyonaga, Takashi; Murakami, Takaaki; Hirose, Ryohei; Ogiso, Kiyoshi; Inada, Yutaka; Rani, Rafiz Abdul; Naito, Yuji; Kishimoto, Mitsuo; Ohara, Yoshiko; Azuma, Takeshi; Itoh, Yoshito

    2017-01-01

    With respect to the knife's design in colorectal endoscopic submucosal dissection (ESD), diameter, water jet function, and electric power are important because these relate to efficient dissection. In this study, we analyzed a novel, narrow ball tip-typed ESD knife with water jet function (Flush knife BT-S, diameter: 2.2 mm, length: 2000 mm, Fujifilm Co., Tokyo, Japan) compared to a regular diameter knife (Flush knife BT, diameter: 2.6 mm, length: 1800 mm). In laboratory and clinical research, electric power, knife insertion time, vacuum/suction amount with knife in the endoscopic channel, and water jet function were analyzed. We used a knife 2.0 mm long for BT-S and BT knives. The BT-S showed faster mean knife insertion time (sec) and better vacuum amount (ml/min) compared to the BT (insertion time: 16.7 versus 21.6, p < 0.001, vacuum amount: 38.0 versus 14.0, p < 0.01). Additionally, the water jet function of the BT-S was not inferior. In 39 colorectal ESD cases in two institutions, there were mean 4.7 times (range: 1-28) of knife insertion. Suction under knife happened 59% (23/39) and suction of fluid could be done in 100%. Our study showed that the narrow knife allows significantly faster knife insertion, better vacuum function, and effective clinical results.

  17. Smooth DNA transport through a narrowed pore geometry.

    PubMed

    Carson, Spencer; Wilson, James; Aksimentiev, Aleksei; Wanunu, Meni

    2014-11-18

    Voltage-driven transport of double-stranded DNA through nanoscale pores holds much potential for applications in quantitative molecular biology and biotechnology, yet the microscopic details of translocation have proven to be challenging to decipher. Earlier experiments showed strong dependence of transport kinetics on pore size: fast regular transport in large pores (> 5 nm diameter), and slower yet heterogeneous transport time distributions in sub-5 nm pores, which imply a large positional uncertainty of the DNA in the pore as a function of the translocation time. In this work, we show that this anomalous transport is a result of DNA self-interaction, a phenomenon that is strictly pore-diameter dependent. We identify a regime in which DNA transport is regular, producing narrow and well-behaved dwell-time distributions that fit a simple drift-diffusion theory. Furthermore, a systematic study of the dependence of dwell time on DNA length reveals a single power-law scaling of 1.37 in the range of 35-20,000 bp. We highlight the resolution of our nanopore device by discriminating via single pulses 100 and 500 bp fragments in a mixture with >98% accuracy. When coupled to an appropriate sequence labeling method, our observation of smooth DNA translocation can pave the way for high-resolution DNA mapping and sizing applications in genomics.

  18. Smooth DNA Transport through a Narrowed Pore Geometry

    PubMed Central

    Carson, Spencer; Wilson, James; Aksimentiev, Aleksei; Wanunu, Meni

    2014-01-01

    Voltage-driven transport of double-stranded DNA through nanoscale pores holds much potential for applications in quantitative molecular biology and biotechnology, yet the microscopic details of translocation have proven to be challenging to decipher. Earlier experiments showed strong dependence of transport kinetics on pore size: fast regular transport in large pores (> 5 nm diameter), and slower yet heterogeneous transport time distributions in sub-5 nm pores, which imply a large positional uncertainty of the DNA in the pore as a function of the translocation time. In this work, we show that this anomalous transport is a result of DNA self-interaction, a phenomenon that is strictly pore-diameter dependent. We identify a regime in which DNA transport is regular, producing narrow and well-behaved dwell-time distributions that fit a simple drift-diffusion theory. Furthermore, a systematic study of the dependence of dwell time on DNA length reveals a single power-law scaling of 1.37 in the range of 35–20,000 bp. We highlight the resolution of our nanopore device by discriminating via single pulses 100 and 500 bp fragments in a mixture with >98% accuracy. When coupled to an appropriate sequence labeling method, our observation of smooth DNA translocation can pave the way for high-resolution DNA mapping and sizing applications in genomics. PMID:25418307

  19. Narrowing the Achievement Gap: A Case Study of an Urban School

    ERIC Educational Resources Information Center

    Lugo, Rosalinda

    2010-01-01

    The goal of this case study was to identify the cultural norms, practices, and programs of an urban school that narrowed the achievement gap. The reason for identifying these factors in a successful school was to add to the body of literature regarding the achievement gap and what a struggling school was able to do to narrow the gap. This case…

  20. Hybrid neuro-heuristic methodology for simulation and control of dynamic systems over time interval.

    PubMed

    Woźniak, Marcin; Połap, Dawid

    2017-09-01

    Simulation and positioning are very important aspects of computer aided engineering. To process these two, we can apply traditional methods or intelligent techniques. The difference between them is in the way they process information. In the first case, to simulate an object in a particular state of action, we need to perform an entire process to read values of parameters. It is not very convenient for objects for which simulation takes a long time, i.e. when mathematical calculations are complicated. In the second case, an intelligent solution can efficiently help on devoted way of simulation, which enables us to simulate the object only in a situation that is necessary for a development process. We would like to present research results on developed intelligent simulation and control model of electric drive engine vehicle. For a dedicated simulation method based on intelligent computation, where evolutionary strategy is simulating the states of the dynamic model, an intelligent system based on devoted neural network is introduced to control co-working modules while motion is in time interval. Presented experimental results show implemented solution in situation when a vehicle transports things over area with many obstacles, what provokes sudden changes in stability that may lead to destruction of load. Therefore, applied neural network controller prevents the load from destruction by positioning characteristics like pressure, acceleration, and stiffness voltage to absorb the adverse changes of the ground. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Physical inactivity is associated with narrower lumbar intervertebral discs, high fat content of paraspinal muscles and low back pain and disability.

    PubMed

    Teichtahl, Andrew J; Urquhart, Donna M; Wang, Yuanyuan; Wluka, Anita E; O'Sullivan, Richard; Jones, Graeme; Cicuttini, Flavia M

    2015-05-07

    Although physical inactivity has been associated with numerous chronic musculoskeletal complaints, few studies have examined its associations with spinal structures. Moreover, previously reported associations between physical activity and low back pain are conflicting. This study examined the associations between physical inactivity and intervertebral disc height, paraspinal fat content and low back pain and disability. Seventy-two community-based volunteers not selected for low back pain underwent magnetic resonance imaging (MRI) of their lumbosacral spine (L1 to S1) between 2011 and 2012. Physical activity was assessed between 2005 and 2008 by questionnaire, while low back pain and disability were assessed by the Chronic Pain Grade Scale at the time of MRI. Intervertebral disc height and cross-sectional area and fat content of multifidus and erector spinae were assessed from MRI. Lower physical activity levels were associated with a more narrow average intervertebral disc height (β -0.63 mm, 95% confidence interval (CI) -1.17 mm to -0.08 mm, P = 0.026) after adjusting for age, gender and body mass index (BMI). There were no significant associations between physical activity levels and the cross-sectional area of multifidus or erector spinae. Lower levels of physical activity were associated with an increased risk of high fat content in multifidus (odds ratio (OR) 2.7, 95% CI 1.1 to 6.7, P = 0.04) and high-intensity pain/disability (OR = 5.0, 95% CI 1.5 to 16.4, P = 0.008) after adjustment for age, gender and BMI. Physical inactivity is associated with narrower intervertebral discs, high fat content of the multifidus and high-intensity low back pain and disability in a dose-dependent manner among community-based adults. Longitudinal studies will help to determine the cause and effect nature of these associations.

  2. Effects of physical guidance on short-term learning of walking on a narrow beam

    PubMed Central

    Domingo, Antoinette; Ferris, Daniel P.

    2009-01-01

    Physical guidance is often used in rehabilitation when teaching patients to re-learn movements. However, the effects of guidance on motor learning of complex skills, such as walking balance, are not clear. We tested four groups of healthy subjects that practiced walking on a narrow (1.27 cm) or wide (2.5 cm) treadmill-mounted balance beam, with or without physical guidance. Assistance was given by springs attached to a hip belt that applied restoring forces towards beam center. Subjects were evaluated while walking unassisted before and after training by calculating the number of times subjects stepped off of the beam per minute of successful walking on the beam (Failures per Minute). Subjects in Unassisted groups had greater performance improvements in walking balance from pre to post compared to subjects in Assisted groups. During training, Unassisted groups had more Failures per Minute than Assisted groups. Performance improvements were smaller in Narrow Beam groups than in Wide Beam groups. The Unassisted-Wide and Assisted-Narrow groups had similar Failures per Minute during training, but the Unassisted-Wide group had much greater performance gains after training. These results suggest that physical assistance can hinder motor learning of walking balance, assistance appears less detrimental for more difficult tasks, and task-specific dynamics are important to learning independent of error experience. PMID:19674900

  3. Effects of physical guidance on short-term learning of walking on a narrow beam.

    PubMed

    Domingo, Antoinette; Ferris, Daniel P

    2009-11-01

    Physical guidance is often used in rehabilitation when teaching patients to re-learn movements. However, the effects of guidance on motor learning of complex skills, such as walking balance, are not clear. We tested four groups of healthy subjects that practiced walking on a narrow (1.27 cm) or wide (2.5 cm) treadmill-mounted balance beam, with or without physical guidance. Assistance was given by springs attached to a hip belt that applied restoring forces towards beam center. Subjects were evaluated while walking unassisted before and after training by calculating the number of times subjects stepped off of the beam per minute of successful walking on the beam (Failures per Minute). Subjects in Unassisted groups had greater performance improvements in walking balance from pre to post compared to subjects in Assisted groups. During training, Unassisted groups had more Failures per Minute than Assisted groups. Performance improvements were smaller in Narrow Beam groups than in Wide Beam groups. The Unassisted-Wide and Assisted-Narrow groups had similar Failures per Minute during training, but the Unassisted-Wide group had much greater performance gains after training. These results suggest that physical assistance can hinder motor learning of walking balance, assistance appears less detrimental for more difficult tasks, and task-specific dynamics are important to learning independent of error experience.

  4. Constraint-based Attribute and Interval Planning

    NASA Technical Reports Server (NTRS)

    Jonsson, Ari; Frank, Jeremy

    2013-01-01

    In this paper we describe Constraint-based Attribute and Interval Planning (CAIP), a paradigm for representing and reasoning about plans. The paradigm enables the description of planning domains with time, resources, concurrent activities, mutual exclusions among sets of activities, disjunctive preconditions and conditional effects. We provide a theoretical foundation for the paradigm, based on temporal intervals and attributes. We then show how the plans are naturally expressed by networks of constraints, and show that the process of planning maps directly to dynamic constraint reasoning. In addition, we de ne compatibilities, a compact mechanism for describing planning domains. We describe how this framework can incorporate the use of constraint reasoning technology to improve planning. Finally, we describe EUROPA, an implementation of the CAIP framework.

  5. High prevalence of narrow angles among Chinese-American glaucoma and glaucoma suspect patients.

    PubMed

    Seider, Michael I; Pekmezci, Melike; Han, Ying; Sandhu, Simi; Kwok, Shiu Y; Lee, Roland Y; Lin, Shan C

    2009-01-01

    To evaluate the prevalence of gonioscopically narrow angles in a Chinese-American population with glaucoma or glaucoma suspicion. Charts from all Chinese-American patients seen in a comprehensive ophthalmology clinic in the Chinatown district of San Francisco in 2002 were reviewed. One eye from each patient with glaucoma or glaucoma suspicion that met inclusion criteria was included (n=108). Data were collected for sex, age, race (self-declared), refraction (spherical equivalent), intraocular pressure, gonioscopy, and vertical cup-to-disk ratio. Sixty percent (n=65) of Chinese-American eyes with glaucoma or glaucoma suspicion had gonioscopically narrow angles (Shaffer grade < or = 2 in 3 or more quadrants). Those with narrow angles were significantly older (P=0.004) than their open angle counterparts, but the 2 groups did not differ in terms of sex, refraction, intraocular pressure, or cup-to-disk ratio (all, P > or = 0.071). In a multivariate model including age, sex, and refraction as predictors of angle grade (open or narrow), only age was a significant predictor of angle grade (P=0.004). A large proportion of Chinese-Americans in our study population with glaucoma or glaucoma suspicion had gonioscopically narrow angles. In multivariate analysis, patients with narrow angles were older than those with open angles but did not differ from them in terms of sex or refraction. Continued evaluation of angle closure glaucoma risk among Chinese-Americans is needed.

  6. Classification mapping and species identification of salt marshes based on a short-time interval NDVI time-series from HJ-1 optical imagery

    NASA Astrophysics Data System (ADS)

    Sun, Chao; Liu, Yongxue; Zhao, Saishuai; Zhou, Minxi; Yang, Yuhao; Li, Feixue

    2016-03-01

    Salt marshes are seen as the most dynamic and valuable ecosystems in coastal zones, and in these areas, it is crucial to obtain accurate remote sensing information on the spatial distributions of species over time. However, discriminating various types of salt marsh is rather difficult because of their strong spectral similarities. Previous salt marsh mapping studies have focused mainly on high spatial and spectral (i.e., hyperspectral) resolution images combined with auxiliary information; however, the results are often limited to small regions. With a high temporal and moderate spatial resolution, the Chinese HuanJing-1 (HJ-1) satellite optical imagery can be used not only to monitor phenological changes of salt marsh vegetation over short-time intervals, but also to obtain coverage of large areas. Here, we apply HJ-1 satellite imagery to the middle coast of Jiangsu in east China to monitor changes in saltmarsh vegetation cover. First, we constructed a monthly NDVI time-series to classify various types of salt marsh and then we tested the possibility of using compressed time-series continuously, to broaden the applicability of this particular approach. Our principal findings are as follows: (1) the overall accuracy of salt marsh mapping based on the monthly NDVI time-series was 90.3%, which was ∼16.0% higher than the single-phase classification strategy; (2) a compressed time-series, including NDVI from six key months (April, June-September, and November), demonstrated very little reduction (2.3%) in overall accuracy but led to obvious improvements in unstable regions; and (3) a simple rule for Spartina alterniflora identification was established using a scene solely from November, which may provide an effective way for regularly monitoring its distribution.

  7. Search for narrow-width tt(bar) resonances in pp(bar) collisons at sqrt(s)=1.8TeV

    NASA Astrophysics Data System (ADS)

    Jain, Supriya

    2004-03-01

    We present a preliminary result on a search for narrow-width resonances that decay into ttbar pairs using 130 pb^{-1} of lepton plus jets data in ppbar collisions at center of mass energy = 1.8 TeV. No significant deviation from Standard Model prediction is observed. 95% C.L. upper limits on the production cross section of the narrow-width resonance times its branching fraction to ttbar are presented for different resonance masses, M_X. We also exclude the existence of a leptophobic topcolor particle, X, with M_X < 560 GeV/c^2 for a width \\Gamma_X = 0.012 M_X.

  8. Feeding Intervals in Premature Infants ≤1750 g: An Integrative Review.

    PubMed

    Binchy, Áine; Moore, Zena; Patton, Declan

    2018-06-01

    The timely establishment of enteral feeds and a reduction in the number of feeding interruptions are key to achieving optimal nutrition in premature infants. Nutritional guidelines vary widely regarding feeding regimens and there is not a widely accepted consensus on the optimal feeding interval. To critically examine the evidence to determine whether there is a relationship to feeding intervals and feeding outcomes in premature infants. A systematic review of the literature in the following databases: PubMed, CINAHL, Embase and the Cochrane Library. The search strategy used the terms infant premature, low birth weight, enteral feeding, feed tolerance and feed intervals. Search results yielded 10 studies involving 1269 infants (birth weight ≤1750 g). No significant differences in feed intolerance, growth, or incidence of necrotizing enterocolitis were observed. Evidence suggests that infants fed at 2 hourly intervals reached full feeds faster than at 3 hourly intervals, had fewer days on parenteral nutrition, and fewer days in which feedings were withheld. Decrease in the volume of gastric residuals and feeding interruptions were observed in the infants fed at 3 hourly intervals than those who were continuously fed. Reducing the feed interval from 3 to 2 hourly increases nurse workload, yet may improve feeding outcomes by reducing the time to achieve full enteral feeding. Studies varied greatly in the definition and management of feeding intolerance and in how outcomes were measured, analyzed, and reported. The term "intermittent" is used widely but can refer to a 2 or 3 hourly interval.

  9. A Novel Finite-Sum Inequality-Based Method for Robust H∞ Control of Uncertain Discrete-Time Takagi-Sugeno Fuzzy Systems With Interval-Like Time-Varying Delays.

    PubMed

    Zhang, Xian-Ming; Han, Qing-Long; Ge, Xiaohua

    2017-09-22

    This paper is concerned with the problem of robust H∞ control of an uncertain discrete-time Takagi-Sugeno fuzzy system with an interval-like time-varying delay. A novel finite-sum inequality-based method is proposed to provide a tighter estimation on the forward difference of certain Lyapunov functional, leading to a less conservative result. First, an auxiliary vector function is used to establish two finite-sum inequalities, which can produce tighter bounds for the finite-sum terms appearing in the forward difference of the Lyapunov functional. Second, a matrix-based quadratic convex approach is employed to equivalently convert the original matrix inequality including a quadratic polynomial on the time-varying delay into two boundary matrix inequalities, which delivers a less conservative bounded real lemma (BRL) for the resultant closed-loop system. Third, based on the BRL, a novel sufficient condition on the existence of suitable robust H∞ fuzzy controllers is derived. Finally, two numerical examples and a computer-simulated truck-trailer system are provided to show the effectiveness of the obtained results.

  10. A simplified scheme for generating narrow-band mid-ultraviolet laser radiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Almog, G.; Ludwig-Maximilians-Universität, Geschwister-Scholl-Platz 1, 80539 München; Scholz, M., E-mail: Matthias.Scholz@toptica.com

    2015-03-15

    We report on the development and characterization of continuous, narrow-band, and tunable laser systems that use direct second-harmonic generation from blue and green diode lasers with an output power level of up to 11.1 mW in the mid-ultraviolet. One of our laser systems was tuned to the mercury 6{sup 1}S{sub 0} → 6{sup 3}P{sub 1} intercombination line at 253.7 nm. We could perform Doppler-free saturation spectroscopy on this line and were able to lock our laser to the transition frequency on long time scales.

  11. High-resolution endoscopy plus chromoendoscopy or narrow-band imaging in Barrett's esophagus: a prospective randomized crossover study.

    PubMed

    Kara, M A; Peters, F P; Rosmolen, W D; Krishnadath, K K; ten Kate, F J; Fockens, P; Bergman, J J G H

    2005-10-01

    High-resolution endoscopy (HRE) may improve the detection of early neoplasia in Barrett's esophagus. Indigo carmine chromoendoscopy (ICC) and narrow-band imaging (NBI) may be useful techniques to complement HRE. The aim of this study was to compare HRE-ICC with HRE-NBI for the detection of high-grade dysplasia or early cancer (HGD/EC) in patients with Barrett's esophagus. Twenty-eight patients with Barrett's esophagus underwent HRE-ICC and HRE-NBI (separated by 6 - 8 weeks) in a randomized sequence. The two procedures were performed by two different endoscopists, who were blinded to the findings of the other examination. Targeted biopsies were taken from all detected lesions, followed by four-quadrant biopsies at 2-cm intervals. Biopsy evaluation was supervised by a single expert pathologist, who was blinded to the imaging technique used. Fourteen patients were diagnosed with HGD/EC. The sensitivity for HGD/EC was 93 % and 86 % for HRE-ICC and HRE-NBI, respectively. Targeted biopsies had a sensitivity of 79 % with HRE alone. HGD was diagnosed from random biopsies alone in only one patient. ICC and NBI detected a limited number of additional lesions occult to HRE, but these lesions did not alter the sensitivity for identifying patients with HGD/EC. In most patients with high-grade dysplasia or early cancer in Barrett's esophagus, subtle lesions can be identified with high-resolution endoscopy. Indigo carmine chromoendoscopy and narrow-band imaging are comparable as adjuncts to high-resolution endoscopy.

  12. Keeping the Edges Sharp I: Honing the Theory of Narrow Rings

    NASA Astrophysics Data System (ADS)

    Hamilton, Douglas P.; Rimlinger, Thomas; Hahn, Joseph M.

    2016-05-01

    Most of the rings that encircle Saturn, Uranus, and Neptune are very narrow structures with typical radial widths of just a few kilometers. Such extreme sharpness is surprising, as even slightly different orbital periods should allow ring particles to continually jostle one another in collisions that preserve angular momentum whileinexorably draining energy. Sharp edges should blur as rings spread in response to collisions and yet they do not. The generally accepted solution to this dilemma is to bracket each narrow ring with a pair of shepherding satellites that can pump energy back into the ring to replace that lost by collisions. But only a disappointing two of roughly twenty narrow rings actually have known attendant satellites. We present a compelling alternative in which the slight eccentricities and inclinations of narrow ringlets act as internal energy sources that can be tapped to prevent ring spreading. When unattended circular rings dissipate energy they must spread radially in order to preserve angular momentum. By contrast, eccentric or inclined rings have an extra degree of freedom that can be exploited to prevent radial spreading; energy is dissipated while keeping z-component of angular momentum, sqrt(a(1-e^2))cos(i), constant by simply decreasing the overall eccentricity (e) and/or inclination (i) of the entire ring. A real narrow ring moves inward as a unit, circularizes, and drops into the equatorial plane in a process that deters radial spreading for millions or billions of years. Using secular theory with dissipation (Zhang et al. 2013), we show that narrow rings are secular eigenstates in which ellipses are nested with pericenters almost, but not exactly aligned. The misalignment of pericenters is crucial in allowing energy dissipation to be shared evenly across the ring. We predict ring surface densities that are roughly constant across the ring's width, in contrast to profiles expected for shepherded rings. Rimlinger et al. (this meeting

  13. Modified stochastic fragmentation of an interval as an ageing process

    NASA Astrophysics Data System (ADS)

    Fortin, Jean-Yves

    2018-02-01

    We study a stochastic model based on modified fragmentation of a finite interval. The mechanism consists of cutting the interval at a random location and substituting a unique fragment on the right of the cut to regenerate and preserve the interval length. This leads to a set of segments of random sizes, with the accumulation of small fragments near the origin. This model is an example of record dynamics, with the presence of ‘quakes’ and slow dynamics. The fragment size distribution is a universal inverse power law with logarithmic corrections. The exact distribution for the fragment number as function of time is simply related to the unsigned Stirling numbers of the first kind. Two-time correlation functions are defined, and computed exactly. They satisfy scaling relations, and exhibit aging phenomena. In particular, the probability that the same number of fragments is found at two different times t>s is asymptotically equal to [4πlog(s)]-1/2 when s\\gg 1 and the ratio t/s is fixed, in agreement with the numerical simulations. The same process with a reset impedes the aging phenomenon-beyond a typical time scale defined by the reset parameter.

  14. Application of narrow-band television to industrial and commercial communications

    NASA Technical Reports Server (NTRS)

    Embrey, B. C., Jr.; Southworth, G. R.

    1974-01-01

    The development of narrow-band systems for use in space systems is presented. Applications of the technology to future spacecraft requirements are discussed along with narrow-band television's influence in stimulating development within the industry. The transferral of the technology into industrial and commercial communications is described. Major areas included are: (1) medicine; (2) education; (3) remote sensing for traffic control; and (5) weather observation. Applications in data processing, image enhancement, and information retrieval are provided by the combination of the TV camera and the computer.

  15. Timing During Interruptions in Timing

    ERIC Educational Resources Information Center

    Fortin, Claudette; Bedard, Marie-Claude; Champagne, Julie

    2005-01-01

    Duration and location of breaks in time interval production were manipulated in various conditions of stimulus presentation (Experiments 1-4). Produced intervals shortened and then stabilized as break duration lengthened, suggesting that participants used the break as a preparatory period to restart timing as quickly as possible at the end of the…

  16. 78 FR 10130 - Narrow Woven Ribbons With Woven Selvedge From the People's Republic of China: Final Results of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-13

    ... Department selected two respondents for review, Precious Planet Ribbons & Bows Co., Ltd. (``Precious Planet'') and Hubschercorp. On January 24, 2012, Precious Planet timely withdrew its request for an...\\ See Letter from Precious Planet to the Secretary of Commerce, ``Narrow Woven Ribbons With Woven...

  17. Not All Prehospital Time is Equal: Influence of Scene Time on Mortality

    PubMed Central

    Brown, Joshua B.; Rosengart, Matthew R.; Forsythe, Raquel M.; Reynolds, Benjamin R.; Gestring, Mark L.; Hallinan, William M.; Peitzman, Andrew B.; Billiar, Timothy R.; Sperry, Jason L.

    2016-01-01

    Background Trauma is time-sensitive and minimizing prehospital (PH) time is appealing. However, most studies have not linked increasing PH time with worse outcomes, as raw PH times are highly variable. It is unclear whether specific PH time patterns affect outcomes. Our objective was to evaluate the association of PH time interval distribution with mortality. Methods Patients transported by EMS in the Pennsylvania trauma registry 2000-2013 with total prehospital time (TPT)≥20min were included. TPT was divided into three PH time intervals: response, scene, and transport time. The number of minutes in each PH time interval was divided by TPT to determine the relative proportion each interval contributed to TPT. A prolonged interval was defined as any one PH interval contributing ≥50% of TPT. Patients were classified by prolonged PH interval or no prolonged PH interval (all intervals<50% of TPT). Patients were matched for TPT and conditional logistic regression determined the association of mortality with PH time pattern, controlling for confounders. PH interventions were explored as potential mediators, and prehospital triage criteria used identify patients with time-sensitive injuries. Results There were 164,471 patients included. Patients with prolonged scene time had increased odds of mortality (OR 1.21; 95%CI 1.02–1.44, p=0.03). Prolonged response, transport, and no prolonged interval were not associated with mortality. When adjusting for mediators including extrication and PH intubation, prolonged scene time was no longer associated with mortality (OR 1.06; 0.90–1.25, p=0.50). Together these factors mediated 61% of the effect between prolonged scene time and mortality. Mortality remained associated with prolonged scene time in patients with hypotension, penetrating injury, and flail chest. Conclusions Prolonged scene time is associated with increased mortality. PH interventions partially mediate this association. Further study should evaluate whether

  18. Narrow-band filters for the lightning imager

    NASA Astrophysics Data System (ADS)

    Piegari, Angela; Di Sarcina, Ilaria; Grilli, Maria Luisa; Menchini, Francesca; Scaglione, Salvatore; Sytchkova, Anna; Zola, Danilo; Cuevas, Leticia P.

    2017-11-01

    The study of lightning phenomena will be carried out by a dedicated instrument, the lightning imager, that will make use of narrow-band transmission filters for separating the Oxygen emission lines in the clouds, from the background signal. The design, manufacturing and testing of these optical filters will be described here.

  19. Determinants of lens vault and association with narrow angles in patients from Singapore.

    PubMed

    Tan, Gavin S; He, Mingguang; Zhao, Wanting; Sakata, Lisandro M; Li, Jialiang; Nongpiur, Monisha E; Lavanya, Raghavan; Friedman, David S; Aung, Tin

    2012-07-01

    To describe the distribution and determinants of lens vault and to investigate the association of lens vault with narrow angles. Prospective cross-sectional study. Phakic subjects 50 years and older were evaluated at a primary healthcare clinic with gonioscopy, partial laser interferometry, and anterior segment optical coherence tomography (AS-OCT). Narrow angles were defined as posterior trabecular meshwork not visible for ≥2 quadrants on non-indentation gonioscopy. Lens vault was defined as the perpendicular distance between the anterior pole of the crystalline lens and the horizontal line joining the 2 scleral spurs on horizontal AS-OCT scans. Analysis of covariance, multivariate logistic regression, and area under the receiver operating characteristic curves (AUC) were performed. Of the 2047 subjects recruited, 582 were excluded because of poor image quality or inability to locate scleral spurs, leaving 1465 subjects for analysis. Eyes with narrow angles had greater lens vault compared to eyes with open angles (775.6 µm vs 386.5 µm, P < .0001). Women had significantly greater lens vault than men (497.28 µm vs 438.56 µm, P < .001), and lens vault increased significantly with age (P for trend <.001). Adjusted for age and sex, significant associations with greater lens vault were shorter axial length, shallower anterior chamber depth(ACD), higher intraocular pressure, and more hyperopic spherical equivalent (all P < .001). On multivariate analysis, subjects with lens vault >667.6 µm were more likely to have narrow angles (OR 2.201, 95% CI: 1.070-4.526) compared to those with lens vault ≤462.7 µm. The AUC for lens vault (0.816) and ACD (0.822) for detecting narrow angles were similar (P = .582). Lens vault was independently associated with narrow angles and may be useful in screening to detect eyes with narrow angles. Copyright © 2012 Elsevier Inc. All rights reserved.

  20. High Prevalence of Narrow Angles among Chinese-American Glaucoma and Glaucoma Suspect Patients

    PubMed Central

    Seider, Michael I; Pekmezci, Melike; Han, Ying; Sandhu, Simi; Kwok, Shiu Y; Lee, Roland Y; Lin, Shan C

    2009-01-01

    Purpose To evaluate the prevalence of gonioscopically narrow angles in a Chinese-American population with glaucoma or glaucoma suspicion. Patients and Methods Charts from all Chinese-American patients seen in a comprehensive ophthalmology clinic in the Chinatown district of San Francisco in 2002 were reviewed. One eye from each patient with glaucoma or glaucoma suspicion that met inclusion criteria was included (n=108). Data was collected for gender, age, race (self-declared), refraction (spherical equivalent), intraocular pressure (IOP), gonioscopy and vertical cup-to-disk ratio (CDR). Results Sixty percent (n=65) of Chinese-American eyes with glaucoma or glaucoma suspicion had gonioscopically narrow angles (Shaffer grade ≤2 in three or more quadrants). Those with narrow angles were significantly older (P=0.004) than their open angle counterparts, but the two groups did not differ in terms of gender, refraction, IOP or CDR (all, P≥0.071). In a multivariate model including age, gender and refraction as predictors of angle grade (open or narrow), only age was a significant predictor of angle grade (P=0.004). Conclusions A large proportion of Chinese-Americans in our study population with glaucoma or glaucoma suspicion had gonioscopically narrow angles. In multivariate analysis, patients with narrow angles were older than those with open angles but did not differ from them in terms of gender or refraction. Continued evaluation of angle closure glaucoma risk among Chinese-Americans is needed. PMID:19826385

  1. Neural activity underlying motor-action preparation and cognitive narrowing in approach-motivated goal states.

    PubMed

    Gable, Philip A; Threadgill, A Hunter; Adams, David L

    2016-02-01

    High-approach-motivated (pre-goal) positive affect states encourage tenacious goal pursuit and narrow cognitive scope. As such, high approach-motivated states likely enhance the neural correlates of motor-action preparation to aid in goal acquisition. These neural correlates may also relate to the cognitive narrowing associated with high approach-motivated states. In the present study, we investigated motor-action preparation during pre-goal and post-goal states using an index of beta suppression over the motor cortex. The results revealed that beta suppression was greatest in pre-goal positive states, suggesting that higher levels of motor-action preparation occur during high approach-motivated positive states. Furthermore, beta and alpha suppression in the high approach-motivated positive states predicted greater cognitive narrowing. These results suggest that approach-motivated pre-goal states engage the neural substrates of motor-action preparation and cognitive narrowing. Individual differences in motor-action preparation relate to the degree of cognitive narrowing.

  2. A comparative analysis of spectral exponent estimation techniques for 1/fβ processes with applications to the analysis of stride interval time series

    PubMed Central

    Schaefer, Alexander; Brach, Jennifer S.; Perera, Subashan; Sejdić, Ervin

    2013-01-01

    Background The time evolution and complex interactions of many nonlinear systems, such as in the human body, result in fractal types of parameter outcomes that exhibit self similarity over long time scales by a power law in the frequency spectrum S(f) = 1/fβ. The scaling exponent β is thus often interpreted as a “biomarker” of relative health and decline. New Method This paper presents a thorough comparative numerical analysis of fractal characterization techniques with specific consideration given to experimentally measured gait stride interval time series. The ideal fractal signals generated in the numerical analysis are constrained under varying lengths and biases indicative of a range of physiologically conceivable fractal signals. This analysis is to complement previous investigations of fractal characteristics in healthy and pathological gait stride interval time series, with which this study is compared. Results The results of our analysis showed that the averaged wavelet coefficient method consistently yielded the most accurate results. Comparison with Existing Methods: Class dependent methods proved to be unsuitable for physiological time series. Detrended fluctuation analysis as most prevailing method in the literature exhibited large estimation variances. Conclusions The comparative numerical analysis and experimental applications provide a thorough basis for determining an appropriate and robust method for measuring and comparing a physiologically meaningful biomarker, the spectral index β. In consideration of the constraints of application, we note the significant drawbacks of detrended fluctuation analysis and conclude that the averaged wavelet coefficient method can provide reasonable consistency and accuracy for characterizing these fractal time series. PMID:24200509

  3. A comparative analysis of spectral exponent estimation techniques for 1/f(β) processes with applications to the analysis of stride interval time series.

    PubMed

    Schaefer, Alexander; Brach, Jennifer S; Perera, Subashan; Sejdić, Ervin

    2014-01-30

    The time evolution and complex interactions of many nonlinear systems, such as in the human body, result in fractal types of parameter outcomes that exhibit self similarity over long time scales by a power law in the frequency spectrum S(f)=1/f(β). The scaling exponent β is thus often interpreted as a "biomarker" of relative health and decline. This paper presents a thorough comparative numerical analysis of fractal characterization techniques with specific consideration given to experimentally measured gait stride interval time series. The ideal fractal signals generated in the numerical analysis are constrained under varying lengths and biases indicative of a range of physiologically conceivable fractal signals. This analysis is to complement previous investigations of fractal characteristics in healthy and pathological gait stride interval time series, with which this study is compared. The results of our analysis showed that the averaged wavelet coefficient method consistently yielded the most accurate results. Class dependent methods proved to be unsuitable for physiological time series. Detrended fluctuation analysis as most prevailing method in the literature exhibited large estimation variances. The comparative numerical analysis and experimental applications provide a thorough basis for determining an appropriate and robust method for measuring and comparing a physiologically meaningful biomarker, the spectral index β. In consideration of the constraints of application, we note the significant drawbacks of detrended fluctuation analysis and conclude that the averaged wavelet coefficient method can provide reasonable consistency and accuracy for characterizing these fractal time series. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Prevalence of Extracranial Venous Narrowing on Magnetic Resonance Venography Is Similar in People With Multiple Sclerosis, Their Siblings, and Unrelated Healthy Controls: A Blinded, Case-Control Study.

    PubMed

    Martin, Nancy; Traboulsee, Anthony L; Machan, Lindsay; Klass, Darren; Ellchuk, Tasha; Zhao, Yinshan; Knox, Katherine B; Kopriva, David; Lala, Shantilal; Nickel, Darren; Otani, Robert; Perera, Warren R; Rauscher, Alexander; Sadovnick, A Dessa; Szkup, Peter; Li, David K

    2017-05-01

    The study sought to assess and compare the prevalence of narrowing of the major extracranial veins in subjects with multiple sclerosis and controls, and to assess the sensitivity and specificity of magnetic resonance venography (MRV) for describing extracranial venous narrowing as it applies to the chronic cerebrospinal venous insufficiency theory, using catheter venography (CV) as the gold standard. The jugular and azygos veins were assessed with time-of-flight MRV in this assessor-blinded, case-control study of subjects with multiple sclerosis, their unaffected siblings, and unrelated controls. The veins were evaluated by diameter and area, and compared with CV. Collateral vessels were also analyzed for maximal diameter, as a potential indicator of compensatory flow. A high prevalence of extracranial venous narrowing was demonstrated in all study groups, collectively up to 84% by diameter criteria and 90% by area, with no significant difference between the groups when assessed independently (P = .34 and .63, respectively). There was high interobserver variability in the reporting of vessel narrowing (kappa = 0.32), and poor vessel per vessel correlation between narrowing on MRV and CV (kappa = 0.064). Collateral neck veins demonstrated no convincing difference in maximum size or correlation with jugular narrowing. There is a high prevalence of narrowing of the major extracranial veins on MRV in all 3 study groups, with no significant difference between them. These findings do not support the chronic cerebrospinal venous insufficiency theory. Although MRV has shown a high sensitivity for identifying venous narrowing, time-of-flight imaging demonstrates poor interobserver agreement and poor specificity when compared with the gold standard CV. Copyright © 2016 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  5. On computations of variance, covariance and correlation for interval data

    NASA Astrophysics Data System (ADS)

    Kishida, Masako

    2017-02-01

    In many practical situations, the data on which statistical analysis is to be performed is only known with interval uncertainty. Different combinations of values from the interval data usually lead to different values of variance, covariance, and correlation. Hence, it is desirable to compute the endpoints of possible values of these statistics. This problem is, however, NP-hard in general. This paper shows that the problem of computing the endpoints of possible values of these statistics can be rewritten as the problem of computing skewed structured singular values ν, for which there exist feasible (polynomial-time) algorithms that compute reasonably tight bounds in most practical cases. This allows one to find tight intervals of the aforementioned statistics for interval data.

  6. Symptomatic Versus Inapparent Outcome in Repeat Dengue Virus Infections Is Influenced by the Time Interval between Infections and Study Year

    PubMed Central

    Mercado, Juan Carlos; Williams, Katherine L.; Vargas, Maria José; Gutierrez, Gamaliel; Kuan, Guillermina; Gordon, Aubree; Balmaseda, Angel; Harris, Eva

    2013-01-01

    Four dengue virus serotypes (DENV1-4) circulate globally, causing more human illness than any other arthropod-borne virus. Dengue can present as a range of clinical manifestations from undifferentiated fever to Dengue Fever to severe, life-threatening syndromes. However, most DENV infections are inapparent. Yet, little is known about determinants of inapparent versus symptomatic DENV infection outcome. Here, we analyzed over 2,000 DENV infections from 2004 to 2011 in a prospective pediatric cohort study in Managua, Nicaragua. Symptomatic cases were captured at the study health center, and paired healthy annual samples were examined on a yearly basis using serological methods to identify inapparent DENV infections. Overall, inapparent and symptomatic DENV infections were equally distributed by sex. The mean age of infection was 1.2 years higher for symptomatic DENV infections as compared to inapparent infections. Although inapparent versus symptomatic outcome did not differ by infection number (first, second or third/post-second DENV infections), substantial variation in the proportion of symptomatic DENV infections among all DENV infections was observed across study years. In participants with repeat DENV infections, the time interval between a first inapparent DENV infection and a second inapparent infection was significantly shorter than the interval between a first inapparent and a second symptomatic infection. This difference was not observed in subsequent infections. This result was confirmed using two different serological techniques that measure total anti-DENV antibodies and serotype-specific neutralizing antibodies, respectively. Taken together, these findings show that, in this study, age, study year and time interval between consecutive DENV infections influence inapparent versus symptomatic infection outcome, while sex and infection number had no significant effect. Moreover, these results suggest that the window of cross-protection induced by a first

  7. Why Hart found narrow ecospheres--a minor science mystery solved.

    PubMed

    Levenson, Barton Paul

    2015-05-01

    To explain why two NASA computer simulation studies in the 1970s (Hart, 1978 , 1979 ) briefly rocked the subfield of astrobiology and SETI studies by showing very narrow habitable zones (HZs) for solar-type stars. Although other studies later supported wider HZs, it was never clear why the Hart simulations found the narrow limits they did. Investigation of the state of climate studies and radiative transfer models in the period 1960-1970 provides a likely explanation. Hart's findings were in line with earlier results, preventing him from noticing that his radiation model was inadequate.

  8. Perspective: The Case for an Evidence-Based Reference Interval for Serum Magnesium: The Time Has Come.

    PubMed

    Costello, Rebecca B; Elin, Ronald J; Rosanoff, Andrea; Wallace, Taylor C; Guerrero-Romero, Fernando; Hruby, Adela; Lutsey, Pamela L; Nielsen, Forrest H; Rodriguez-Moran, Martha; Song, Yiqing; Van Horn, Linda V

    2016-11-01

    The 2015 Dietary Guidelines Advisory Committee indicated that magnesium was a shortfall nutrient that was underconsumed relative to the Estimated Average Requirement (EAR) for many Americans. Approximately 50% of Americans consume less than the EAR for magnesium, and some age groups consume substantially less. A growing body of literature from animal, epidemiologic, and clinical studies has demonstrated a varied pathologic role for magnesium deficiency that includes electrolyte, neurologic, musculoskeletal, and inflammatory disorders; osteoporosis; hypertension; cardiovascular diseases; metabolic syndrome; and diabetes. Studies have also demonstrated that magnesium deficiency is associated with several chronic diseases and that a reduced risk of these diseases is observed with higher magnesium intake or supplementation. Subclinical magnesium deficiency can exist despite the presentation of a normal status as defined within the current serum magnesium reference interval of 0.75-0.95 mmol/L. This reference interval was derived from data from NHANES I (1974), which was based on the distribution of serum magnesium in a normal population rather than clinical outcomes. What is needed is an evidenced-based serum magnesium reference interval that reflects optimal health and the current food environment and population. We present herein data from an array of scientific studies to support the perspective that subclinical deficiencies in magnesium exist, that they contribute to several chronic diseases, and that adopting a revised serum magnesium reference interval would improve clinical care and public health. © 2016 American Society for Nutrition.

  9. Positional Asphyxia: Death Due to Unusual Head-Down Position in a Narrow Space.

    PubMed

    Chaudhari, Vinod Ashok; Ghodake, Dattatray G; Kharat, Rajesh D

    2016-06-01

    Death due to a head-down position with hyperflexion of the neck is a rare event. A person accidentally falling into a narrow space and remaining in an upside-down position with no timely recovery may experience positional or postural asphyxia. It is a critical condition arising out of particular body positions, leading to mechanical obstruction of respiration. The precipitating factors are intoxication due to alcohol, drugs, obesity, psychiatric illnesses, and injuries. A 30-year-old unmarried woman, weighing 82 kg and with a body mass index of 31.24, was found in a narrow space between the bed and the wall in a naked state and in a head-down position with hyperflexion of the neck. The distribution of lividity was consistent with the position of the body at the scene. Blood was oozing from the mouth and nostrils, and signs of asphyxia were present. The toxicological analyses of viscera, blood, and urine were negative for alcohol, drugs, and poisons. Glucose levels in the blood (86 mg/dL) as well as urine and vitreous humor levels (68 mg/dL) were within normal limits. On microscopic examination, there were no findings of coronary atherosclerosis, whereas the brain and lung were edematous. After meticulous examination, we ruled out sexual assault, autoerotic asphyxia, epilepsy, psychiatric illness, diabetes, toxicity, and coronary artery disease. Death was attributed to the accidental fall of the obese individual being stuck in a narrow space, resulting in positional asphyxia. It is imperative to recognize the precipitating or risk factors before labeling positional asphyxia as a cause of death.

  10. Automated Interval velocity picking for Atlantic Multi-Channel Seismic Data

    NASA Astrophysics Data System (ADS)

    Singh, Vishwajit

    2016-04-01

    This paper described the challenge in developing and testing a fully automated routine for measuring interval velocities from multi-channel seismic data. Various approaches are employed for generating an interactive algorithm picking interval velocity for continuous 1000-5000 normal moveout (NMO) corrected gather and replacing the interpreter's effort for manual picking the coherent reflections. The detailed steps and pitfalls for picking the interval velocities from seismic reflection time measurements are describe in these approaches. Key ingredients these approaches utilized for velocity analysis stage are semblance grid and starting model of interval velocity. Basin-Hopping optimization is employed for convergence of the misfit function toward local minima. SLiding-Overlapping Window (SLOW) algorithm are designed to mitigate the non-linearity and ill- possessedness of root-mean-square velocity. Synthetic data case studies addresses the performance of the velocity picker generating models perfectly fitting the semblance peaks. A similar linear relationship between average depth and reflection time for synthetic model and estimated models proposed picked interval velocities as the starting model for the full waveform inversion to project more accurate velocity structure of the subsurface. The challenges can be categorized as (1) building accurate starting model for projecting more accurate velocity structure of the subsurface, (2) improving the computational cost of algorithm by pre-calculating semblance grid to make auto picking more feasible.

  11. Efficacy of a Novel Narrow Knife with Water Jet Function for Colorectal Endoscopic Submucosal Dissection

    PubMed Central

    Inada, Yutaka; Rani, Rafiz Abdul; Naito, Yuji; Azuma, Takeshi; Itoh, Yoshito

    2017-01-01

    Backgrounds With respect to the knife's design in colorectal endoscopic submucosal dissection (ESD), diameter, water jet function, and electric power are important because these relate to efficient dissection. In this study, we analyzed a novel, narrow ball tip-typed ESD knife with water jet function (Flush knife BT-S, diameter: 2.2 mm, length: 2000 mm, Fujifilm Co., Tokyo, Japan) compared to a regular diameter knife (Flush knife BT, diameter: 2.6 mm, length: 1800 mm). Methods In laboratory and clinical research, electric power, knife insertion time, vacuum/suction amount with knife in the endoscopic channel, and water jet function were analyzed. We used a knife 2.0 mm long for BT-S and BT knives. Results The BT-S showed faster mean knife insertion time (sec) and better vacuum amount (ml/min) compared to the BT (insertion time: 16.7 versus 21.6, p < 0.001, vacuum amount: 38.0 versus 14.0, p < 0.01). Additionally, the water jet function of the BT-S was not inferior. In 39 colorectal ESD cases in two institutions, there were mean 4.7 times (range: 1–28) of knife insertion. Suction under knife happened 59% (23/39) and suction of fluid could be done in 100%. Conclusions Our study showed that the narrow knife allows significantly faster knife insertion, better vacuum function, and effective clinical results. PMID:29081793

  12. Multimodal transport and dispersion of organelles in narrow tubular cells

    NASA Astrophysics Data System (ADS)

    Mogre, Saurabh S.; Koslover, Elena F.

    2018-04-01

    Intracellular components explore the cytoplasm via active motor-driven transport in conjunction with passive diffusion. We model the motion of organelles in narrow tubular cells using analytical techniques and numerical simulations to study the efficiency of different transport modes in achieving various cellular objectives. Our model describes length and time scales over which each transport mode dominates organelle motion, along with various metrics to quantify exploration of intracellular space. For organelles that search for a specific target, we obtain the average capture time for given transport parameters and show that diffusion and active motion contribute to target capture in the biologically relevant regime. Because many organelles have been found to tether to microtubules when not engaged in active motion, we study the interplay between immobilization due to tethering and increased probability of active transport. We derive parameter-dependent conditions under which tethering enhances long-range transport and improves the target capture time. These results shed light on the optimization of intracellular transport machinery and provide experimentally testable predictions for the effects of transport regulation mechanisms such as tethering.

  13. Looking through an adolescent literacy lens at the narrow view of reading.

    PubMed

    Ehren, Barbara J

    2009-04-01

    This commentary is a personal reaction to A. G. Kamhi's (2007) article on the "narrow view" of reading and his suggestion that this view be adopted as a way to address the reading problems of children and adolescents. In this article, I consider the narrow view of reading from an adolescent literacy perspective and discuss the practical implications of adopting this view in the schools. Discussion revolves around the complexities of reading comprehension, comprehension as a teachable set of complex processes, and the speech-language pathologist's role in reading comprehension. Although I acknowledge that the narrow view of reading may have merit, I opine that it may create more problems than it solves.

  14. Periodic, chaotic, and doubled earthquake recurrence intervals on the deep San Andreas Fault

    USGS Publications Warehouse

    Shelly, David R.

    2010-01-01

    Earthquake recurrence histories may provide clues to the timing of future events, but long intervals between large events obscure full recurrence variability. In contrast, small earthquakes occur frequently, and recurrence intervals are quantifiable on a much shorter time scale. In this work, I examine an 8.5-year sequence of more than 900 recurring low-frequency earthquake bursts composing tremor beneath the San Andreas fault near Parkfield, California. These events exhibit tightly clustered recurrence intervals that, at times, oscillate between ~3 and ~6 days, but the patterns sometimes change abruptly. Although the environments of large and low-frequency earthquakes are different, these observations suggest that similar complexity might underlie sequences of large earthquakes.

  15. Hailey-Hailey disease maps to a 5 cM interval on chromosome 3q21-q24.

    PubMed

    Richard, G; Korge, B P; Wright, A R; Mazzanti, C; Harth, W; Annicchiarico-Petruzzelli, M; Compton, J G; Bale, S J

    1995-09-01

    Hailey-Hailey disease (HHD) is a rare autosomal dominant genodermatosis characterized by disturbed keratinocyte adhesion. The disease has recently been mapped to a 14 cM region on chromosome 3q. We have further refined the location of the HHD gene by linkage analysis in six HHD families from Germany and Italy using 11 polymorphic microsatellite markers and found no evidence for genetic heterogeneity. We observed complete cosegregation between HHD and marker D3S1587, with a maximal lod score of 4.54. Detailed haplotype analyses allowed us to narrow the interval containing the HHD locus to 5 cM, flanked by D3S1589 and D3S1290.

  16. Filling the blanks in temporal intervals: the type of filling influences perceived duration and discrimination performance

    PubMed Central

    Horr, Ninja K.; Di Luca, Massimiliano

    2015-01-01

    In this work we investigate how judgments of perceived duration are influenced by the properties of the signals that define the intervals. Participants compared two auditory intervals that could be any combination of the following four types: intervals filled with continuous tones (filled intervals), intervals filled with regularly-timed short tones (isochronous intervals), intervals filled with irregularly-timed short tones (anisochronous intervals), and intervals demarcated by two short tones (empty intervals). Results indicate that the type of intervals to be compared affects discrimination performance and induces distortions in perceived duration. In particular, we find that duration judgments are most precise when comparing two isochronous and two continuous intervals, while the comparison of two anisochronous intervals leads to the worst performance. Moreover, we determined that the magnitude of the distortions in perceived duration (an effect akin to the filled duration illusion) is higher for tone sequences (no matter whether isochronous or anisochronous) than for continuous tones. Further analysis of how duration distortions depend on the type of filling suggests that distortions are not only due to the perceived duration of the two individual intervals, but they may also be due to the comparison of two different filling types. PMID:25717310

  17. Heat Generation on Implant Surface During Abutment Preparation at Different Elapsed Time Intervals.

    PubMed

    Al-Keraidis, Abdullah; Aleisa, Khalil; Al-Dwairi, Ziad Nawaf; Al-Tahawi, Hamdi; Hsu, Ming-Lun; Lynch, Edward; Özcan, Mutlu

    2017-10-01

    The purpose of this study was to evaluate heat generation at the implant surface caused by abutment preparation using a diamond bur in a high-speed dental turbine in vitro at 2 different water-coolant temperatures. Thirty-two titanium-alloy abutments were connected to a titanium-alloy implant embedded in an acrylic resin placed within a water bath at a controlled temperature of 37°C. The specimens were equally distributed into 2 groups (16 each). Group 1: the temperature was maintained at 20 ± 1°C; and group 2: the temperature was maintained at 32 ± 1°C. Each abutment was prepared in the axial plane for 1 minute and in the occlusal plane for 1 minute. The temperature of the heat generated from abutment preparation was recorded and measured at 3 distinct time intervals. Water-coolant temperature (20°C vs 32°C) had a statistically significant effect on the implant's temperature change during preparation of the abutment (P < 0.0001). The use of water-coolant temperature of 20 ± 1°C during preparation of the implant abutment decreased the temperature recorded at the implant surface to 34.46°C, whereas the coolant temperature of 32 ± 1°C increased the implant surface temperature to 40.94°C.

  18. More reliable protein NMR peak assignment via improved 2-interval scheduling.

    PubMed

    Chen, Zhi-Zhong; Lin, Guohui; Rizzi, Romeo; Wen, Jianjun; Xu, Dong; Xu, Ying; Jiang, Tao

    2005-03-01

    Protein NMR peak assignment refers to the process of assigning a group of "spin systems" obtained experimentally to a protein sequence of amino acids. The automation of this process is still an unsolved and challenging problem in NMR protein structure determination. Recently, protein NMR peak assignment has been formulated as an interval scheduling problem (ISP), where a protein sequence P of amino acids is viewed as a discrete time interval I (the amino acids on P one-to-one correspond to the time units of I), each subset S of spin systems that are known to originate from consecutive amino acids from P is viewed as a "job" j(s), the preference of assigning S to a subsequence P of consecutive amino acids on P is viewed as the profit of executing job j(s) in the subinterval of I corresponding to P, and the goal is to maximize the total profit of executing the jobs (on a single machine) during I. The interval scheduling problem is max SNP-hard in general; but in the real practice of protein NMR peak assignment, each job j(s) usually requires at most 10 consecutive time units, and typically the jobs that require one or two consecutive time units are the most difficult to assign/schedule. In order to solve these most difficult assignments, we present an efficient 13/7-approximation algorithm for the special case of the interval scheduling problem where each job takes one or two consecutive time units. Combining this algorithm with a greedy filtering strategy for handling long jobs (i.e., jobs that need more than two consecutive time units), we obtain a new efficient heuristic for protein NMR peak assignment. Our experimental study shows that the new heuristic produces the best peak assignment in most of the cases, compared with the NMR peak assignment algorithms in the recent literature. The above algorithm is also the first approximation algorithm for a nontrivial case of the well-known interval scheduling problem that breaks the ratio 2 barrier.

  19. Cervical spinal canal narrowing in idiopathic syringomyelia.

    PubMed

    Struck, Aaron F; Carr, Carrie M; Shah, Vinil; Hesselink, John R; Haughton, Victor M

    2016-08-01

    The cervical spine in Chiari I patient with syringomyelia has significantly different anteroposterior diameters than it does in Chiari I patients without syringomyelia. We tested the hypothesis that patients with idiopathic syringomyelia (IS) also have abnormal cervical spinal canal diameters. The finding in both groups may relate to the pathogenesis of syringomyelia. Local institutional review boards approved this retrospective study. Patients with IS were compared to age-matched controls with normal sagittal spine MR. All subjects had T1-weighted spin-echo (500/20) and T2-weighted fast spin-echo (2000/90) sagittal cervical spine images at 1.5 T. Readers blinded to demographic data and study hypothesis measured anteroposterior diameters at each cervical level. The spinal canal diameters were compared with a Mann-Whitney U test. The overall difference was assessed with a Friedman test. Seventeen subjects were read by two reviewers to assess inter-rater reliability. Fifty IS patients with 50 age-matched controls were studied. IS subjects had one or more syrinxes varying from 1 to 19 spinal segments. Spinal canal diameters narrowed from C1 to C3 and then enlarged from C5 to C7 in both groups. Diameters from C2 to C4 were narrower in the IS group (p < 0.005) than in controls. The ratio of the C3 to the C7 diameters was also smaller (p = 0.004) in IS than controls. Collectively, the spinal canal diameters in the IS were significantly different from controls (Friedman test p < 0.0001). Patients with IS have abnormally narrow upper and mid cervical spinal canal diameters and greater positive tapering between C3 and C7.

  20. Studying DDT Susceptibility at Discriminating Time Intervals Focusing on Maximum Limit of Exposure Time Survived by DDT Resistant Phlebotomus argentipes (Diptera: Psychodidae): an Investigative Report.

    PubMed

    Rama, Aarti; Kesari, Shreekant; Das, Pradeep; Kumar, Vijay

    2017-07-24

    Extensive application of routine insecticide i.e., dichlorodiphenyltrichloroethane (DDT) to control Phlebotomus argentipes (Diptera: Psychodidae), the proven vector of visceral leishmaniasis in India, had evoked the problem of resistance/tolerance against DDT, eventually nullifying the DDT dependent strategies to control this vector. Because tolerating an hour-long exposure to DDT is not challenging enough for the resistant P. argentipes, estimating susceptibility by exposing sand flies to insecticide for just an hour becomes a trivial and futile task.Therefore, this bioassay study was carried out to investigate the maximum limit of exposure time to which DDT resistant P. argentipes can endure the effect of DDT for their survival. The mortality rate of laboratory-reared DDT resistant strain P. argentipes exposed to DDT was studied at discriminating time intervals of 60 min and it was concluded that highly resistant sand flies could withstand up to 420 min of exposure to this insecticide. Additionally, the lethal time for female P. argentipes was observed to be higher than for males suggesting that they are highly resistant to DDT's toxicity. Our results support the monitoring of tolerance limit with respect to time and hence points towards an urgent need to change the World Health Organization's protocol for susceptibility identification in resistant P. argentipes.

  1. High Interfacial Barriers at Narrow Carbon Nanotube-Water Interfaces.

    PubMed

    Varanasi, Srinivasa Rao; Subramanian, Yashonath; Bhatia, Suresh K

    2018-06-26

    Water displays anomalous fast diffusion in narrow carbon nanotubes (CNTs), a behavior that has been reproduced in both experimental and simulation studies. However, little is reported on the effect of bulk water-CNT interfaces, which is critical to exploiting the fast transport of water across narrow carbon nanotubes in actual applications. Using molecular dynamics simulations, we investigate here the effect of such interfaces on the transport of water across arm-chair CNTs of different diameters. Our results demonstrate that diffusion of water is significantly retarded in narrow CNTs due to bulk regions near the pore entrance. The slowdown of dynamics can be attributed to the presence of large energy barriers at bulk water-CNT interfaces. The presence of such intense barriers at the bulk-CNT interface arises due to the entropy contrast between the bulk and confined regions, with water molecules undergoing high translational and rotational entropy gain on entering from the bulk to the CNT interior. The intensity of such energy barriers decreases with increase in CNT diameter. These results are very important for emerging technological applications of CNTs and other nanoscale materials, such as in nanofluidics, water purification, nanofiltration, and desalination, as well as for biological transport processes.

  2. Photonic bandgap narrowing in conical hollow core Bragg fibers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ozturk, Fahri Emre; Yildirim, Adem; Kanik, Mehmet

    2014-08-18

    We report the photonic bandgap engineering of Bragg fibers by controlling the thickness profile of the fiber during the thermal drawing. Conical hollow core Bragg fibers were produced by thermal drawing under a rapidly alternating load, which was applied by introducing steep changes to the fiber drawing speed. In conventional cylindrical Bragg fibers, light is guided by omnidirectional reflections from interior dielectric mirrors with a single quarter wave stack period. In conical fibers, the diameter reduction introduced a gradient of the quarter wave stack period along the length of the fiber. Therefore, the light guided within the fiber encountered slightlymore » smaller dielectric layer thicknesses at each reflection, resulting in a progressive blueshift of the reflectance spectrum. As the reflectance spectrum shifts, longer wavelengths of the initial bandgap cease to be omnidirectionally reflected and exit through the cladding, which narrows the photonic bandgap. A narrow transmission bandwidth is particularly desirable in hollow waveguide mid-infrared sensing schemes, where broadband light is coupled to the fiber and the analyte vapor is introduced into the hollow core to measure infrared absorption. We carried out sensing simulations using the absorption spectrum of isopropyl alcohol vapor to demonstrate the importance of narrow bandgap fibers in chemical sensing applications.« less

  3. High prevalence of narrow angles among Filipino-American patients.

    PubMed

    Seider, Michael I; Sáles, Christopher S; Lee, Roland Y; Agadzi, Anthony K; Porco, Travis C; Weinreb, Robert N; Lin, Shan C

    2011-03-01

    To determine the prevalence of gonioscopically narrow anterior chamber angles in a Filipino-American clinic population. The records of 122 consecutive, new, self-declared Filipino-American patients examined in a comprehensive ophthalmology clinic in Vallejo, California were reviewed retrospectively. After exclusion, 222 eyes from 112 patients remained for analysis. Data were collected for anterior chamber angle grade as determined by gonioscopy (Shaffer system), age, sex, manifest refraction (spherical equivalent), intraocular pressure, and cup-to-disk ratio. Data from both eyes of patients were included and modeled using standard linear mixed-effects regression. As a comparison, data were also collected from a group of 30 consecutive White patients from the same clinic. After exclusion, 50 eyes from 25 White patients remained for comparison. At least 1 eye of 24% of Filipino-American patients had a narrow anterior chamber angle (Shaffer grade ≤ 2). Filipino-American angle grade significantly decreased with increasingly hyperopic refraction (P=0.007) and larger cup-to-disk ratio (P=0.038). Filipino-American women had significantly decreased angle grades compared with men (P=0.028), but angle grade did not vary by intraocular pressure or age (all, P≥ 0.059). Narrow anterior chamber angles are highly prevalent in Filipino-American patients in our clinic population.

  4. The Radio-Loud Narrow-Line Quasar SDSS J172206.03+565451.6

    NASA Astrophysics Data System (ADS)

    Komossa, Stefanie; Voges, Wolfgang; Adorf, Hans-Martin; Xu, Dawei; Mathur, Smita; Anderson, Scott F.

    2006-03-01

    We report identification of the radio-loud narrow-line quasar SDSS J172206.03+565451.6, which we found in the course of a search for radio-loud narrow-line active galactic nuclei (AGNs). SDSS J172206.03+565451.6 is only about the fourth securely identified radio-loud narrow-line quasar and the second-most radio loud, with a radio index R1.4~100-700. Its black hole mass, MBH~=(2-3)×107 Msolar estimated from Hβ line width and 5100 Å luminosity, is unusually small given its radio loudness, and the combination of mass and radio index puts SDSS J172206.03+565451.6 in a scarcely populated region of MBH-R diagrams. SDSS J172206.03+565451.6 is a classical narrow-line Seyfert 1-type object with FWHMHβ~=1490 km s-1, an intensity ratio of [O III]/Hβ~=0.7, and Fe II emission complexes with Fe II λ4570/Hβ~=0.7. The ionization parameter of its narrow-line region, estimated from the line ratio [O II]/[O III], is similar to Seyferts, and its high ratio of [Ne V]/[Ne III] indicates a strong EUV-to-soft X-ray excess. We advertise the combined usage of [O II]/[O III] and [Ne V]/[Ne III] diagrams as a useful diagnostic tool to estimate ionization parameters and to constrain the EUV-soft X-ray continuum shape relatively independently from other parameters.

  5. Narrow beam neutron dosimetry.

    PubMed

    Ferenci, M Sutton

    2004-01-01

    Organ and effective doses have been estimated for male and female anthropomorphic mathematical models exposed to monoenergetic narrow beams of neutrons with energies from 10(-11) to 1000 MeV. Calculations were performed for anterior-posterior, posterior-anterior, left-lateral and right-lateral irradiation geometries. The beam diameter used in the calculations was 7.62 cm and the phantoms were irradiated at a height of 1 m above the ground. This geometry was chosen to simulate an accidental scenario (a worker walking through the beam) at Flight Path 30 Left (FP30L) of the Weapons Neutron Research (WNR) Facility at Los Alamos National Laboratory. The calculations were carried out using the Monte Carlo transport code MCNPX 2.5c.

  6. Automatic and Robust Delineation of the Fiducial Points of the Seismocardiogram Signal for Non-invasive Estimation of Cardiac Time Intervals.

    PubMed

    Khosrow-Khavar, Farzad; Tavakolian, Kouhyar; Blaber, Andrew; Menon, Carlo

    2016-10-12

    The purpose of this research was to design a delineation algorithm that could detect specific fiducial points of the seismocardiogram (SCG) signal with or without using the electrocardiogram (ECG) R-wave as the reference point. The detected fiducial points were used to estimate cardiac time intervals. Due to complexity and sensitivity of the SCG signal, the algorithm was designed to robustly discard the low-quality cardiac cycles, which are the ones that contain unrecognizable fiducial points. The algorithm was trained on a dataset containing 48,318 manually annotated cardiac cycles. It was then applied to three test datasets: 65 young healthy individuals (dataset 1), 15 individuals above 44 years old (dataset 2), and 25 patients with previous heart conditions (dataset 3). The algorithm accomplished high prediction accuracy with the rootmean- square-error of less than 5 ms for all the test datasets. The algorithm overall mean detection rate per individual recordings (DRI) were 74, 68, and 42 percent for the three test datasets when concurrent ECG and SCG were used. For the standalone SCG case, the mean DRI was 32, 14 and 21 percent. When the proposed algorithm applied to concurrent ECG and SCG signals, the desired fiducial points of the SCG signal were successfully estimated with a high detection rate. For the standalone case, however, the algorithm achieved high prediction accuracy and detection rate for only the young individual dataset. The presented algorithm could be used for accurate and non-invasive estimation of cardiac time intervals.

  7. Narrow-line laser cooling by adiabatic transfer

    NASA Astrophysics Data System (ADS)

    Norcia, Matthew A.; Cline, Julia R. K.; Bartolotta, John P.; Holland, Murray J.; Thompson, James K.

    2018-02-01

    We propose and demonstrate a novel laser cooling mechanism applicable to particles with narrow-linewidth optical transitions. By sweeping the frequency of counter-propagating laser beams in a sawtooth manner, we cause adiabatic transfer back and forth between the ground state and a long-lived optically excited state. The time-ordering of these adiabatic transfers is determined by Doppler shifts, which ensures that the associated photon recoils are in the opposite direction to the particle’s motion. This ultimately leads to a robust cooling mechanism capable of exerting large forces via a weak transition and with reduced reliance on spontaneous emission. We present a simple intuitive model for the resulting frictional force, and directly demonstrate its efficacy for increasing the total phase-space density of an atomic ensemble. We rely on both simulation and experimental studies using the 7.5 kHz linewidth 1S0 to 3P1 transition in 88Sr. The reduced reliance on spontaneous emission may allow this adiabatic sweep method to be a useful tool for cooling particles that lack closed cycling transitions, such as molecules.

  8. Multifactor analysis of multiscaling in volatility return intervals.

    PubMed

    Wang, Fengzhong; Yamasaki, Kazuko; Havlin, Shlomo; Stanley, H Eugene

    2009-01-01

    We study the volatility time series of 1137 most traded stocks in the U.S. stock markets for the two-year period 2001-2002 and analyze their return intervals tau , which are time intervals between volatilities above a given threshold q . We explore the probability density function of tau , P_(q)(tau) , assuming a stretched exponential function, P_(q)(tau) approximately e;(-tau;(gamma)) . We find that the exponent gamma depends on the threshold in the range between q=1 and 6 standard deviations of the volatility. This finding supports the multiscaling nature of the return interval distribution. To better understand the multiscaling origin, we study how gamma depends on four essential factors, capitalization, risk, number of trades, and return. We show that gamma depends on the capitalization, risk, and return but almost does not depend on the number of trades. This suggests that gamma relates to the portfolio selection but not on the market activity. To further characterize the multiscaling of individual stocks, we fit the moments of tau , mu_(m) identical with(tautau);(m);(1m) , in the range of 10intervals demonstrate the temporal structure of volatilities and our findings suggest that their multiscaling features may be helpful for portfolio optimization.

  9. The impact of labor-saving technology on first birth intervals in rural Ethiopia.

    PubMed

    Gibson, Mhairi; Mace, Ruth

    2002-02-01

    Across the developing world labor-saving technologies introduce considerable savings in the time and energy that women allocate to work. Hormonal studies on natural fertility populations indicate that such a reduction in energetic expenditure (rather than improved nutritional status alone) can lead to increased ovarian function. Other qualitative studies have highlighted a link between labor-saving technology and behavioral changes affecting subsequent age at marriage, which may affect fertility. This biodemographic study was designed to investigate whether these physiological and behavioral changes affect fertility at a population level by focusing on a recent water development scheme in Southern Ethiopia. The demographic consequences of a reduction in women's workload following the installation of water points, specifically the variation in length of first birth interval (time lapsed between marriage and first birth), are investigated. First birth interval length is closely associated with lifetime fertility in populations that do not practice contraception, longer intervals being associated with lower fertility. Using life tables and multivariate hazard modeling techniques a number of significant predictors of first birth interval length are identified. Covariates such as age at marriage, season of marriage, village ecology, and access to improved water supply have significant effects on variation in first birth intervals. When entered into models as a time-varying covariate, access to a water tap stand is associated with an immediate reduction in length of first birth intervals.

  10. Dynamic film thickness between bubbles and wall in a narrow channel

    NASA Astrophysics Data System (ADS)

    Ito, Daisuke; Damsohn, Manuel; Prasser, Horst-Michael; Aritomi, Masanori

    2011-09-01

    The present paper describes a novel technique to characterize the behavior of the liquid film between gas bubbles and the wall in a narrow channel. The method is based on the electrical conductance. Two liquid film sensors are installed on both opposite walls in a narrow rectangular channel. The liquid film thickness underneath the gas bubbles is recorded by the first sensor, while the void fraction information is obtained by measuring the conductance between the pair of opposite sensors. Both measurements are taken on a large two-dimensional domain and with a high speed. This makes it possible to obtain the two-dimensional distribution of the dynamic liquid film between the bubbles and the wall. In this study, this method was applied to an air-water flow ranging from bubbly to churn regimes in the narrow channel with a gap width of 1.5 mm.

  11. Inflammatory response of canine gingiva to a chemical retraction agent placed at different time intervals

    PubMed Central

    Ahmadzadeh, Asadallah; Majd, Naim Erfani; Chasteen, Joseph; Kaviani, Azita; Kavoosi, Mohammad Amin

    2014-01-01

    Background: Exposure of the gingival sulcus while controlling hemorrhage is prerequisites for maximizing treatment outcomes of cervical carious lesions and for obtaining quality impressions for the fabrication of indirect restorations with cervical finish lines. Gingival retraction cords saturated with different chemical agents are widely used for this purpose. The aim of this study was to investigate and compare the inflammatory potential of 15.5%ferric sulfate on connective tissue when placed at different times. Materials and Methods: All procedures were performed on three dogs under general anesthesia. Retraction cords saturated with a 15.5% ferric sulfate solution were placed into the gingival sulcus and evaluated after 3 min and 10 min of exposure to the chemical agent. Excisional biopsies of the exposed gingival tissue were then obtained at intervals of 1 h, 24 h, and 7 days. For all specimens, histology evaluation was performed using light microscopy. Data collected from the microscopic images of all tissue specimens were analyzed by using the Wilcoxon Signed Rank and Kruskal-Wallis Tests. P value less than 0.05 was considered as significant. Results: Histopathologic examination of the biopsied gingival tissue revealed that the ferric sulfate solution caused significant tissue changes at the beginning of both the 3-min and 10-min gingival exposure time (P > 0.05). However, the tissue returned to a normal histological appearance by the end of day 7 in all cases (P > 0.05). Conclusion: The results of this study revealed that the biologic effects of 15.5% ferric sulfate solution are clinically acceptable and reliable when gingival exposure times of 3 min and 10 min are used for gingival retraction. PMID:24688565

  12. Minimax confidence intervals in geomagnetism

    NASA Technical Reports Server (NTRS)

    Stark, Philip B.

    1992-01-01

    The present paper uses theory of Donoho (1989) to find lower bounds on the lengths of optimally short fixed-length confidence intervals (minimax confidence intervals) for Gauss coefficients of the field of degree 1-12 using the heat flow constraint. The bounds on optimal minimax intervals are about 40 percent shorter than Backus' intervals: no procedure for producing fixed-length confidence intervals, linear or nonlinear, can give intervals shorter than about 60 percent the length of Backus' in this problem. While both methods rigorously account for the fact that core field models are infinite-dimensional, the application of the techniques to the geomagnetic problem involves approximations and counterfactual assumptions about the data errors, and so these results are likely to be extremely optimistic estimates of the actual uncertainty in Gauss coefficients.

  13. Five-Year Risk of Interval-Invasive Second Breast Cancer

    PubMed Central

    Buist, Diana S. M.; Houssami, Nehmat; Dowling, Emily C.; Halpern, Elkan F.; Gazelle, G. Scott; Lehman, Constance D.; Henderson, Louise M.; Hubbard, Rebecca A.

    2015-01-01

    Background: Earlier detection of second breast cancers after primary breast cancer (PBC) treatment improves survival, yet mammography is less accurate in women with prior breast cancer. The purpose of this study was to examine women presenting clinically with second breast cancers after negative surveillance mammography (interval cancers), and to estimate the five-year risk of interval-invasive second cancers for women with varying risk profiles. Methods: We evaluated a prospective cohort of 15 114 women with 47 717 surveillance mammograms diagnosed with stage 0-II unilateral PBC from 1996 through 2008 at facilities in the Breast Cancer Surveillance Consortium. We used discrete time survival models to estimate the association between odds of an interval-invasive second breast cancer and candidate predictors, including demographic, PBC, and imaging characteristics. All statistical tests were two-sided. Results: The cumulative incidence of second breast cancers after five years was 54.4 per 1000 women, with 325 surveillance-detected and 138 interval-invasive second breast cancers. The five-year risk of interval-invasive second cancer for women with referent category characteristics was 0.60%. For women with the most and least favorable profiles, the five-year risk ranged from 0.07% to 6.11%. Multivariable modeling identified grade II PBC (odds ratio [OR] = 1.95, 95% confidence interval [CI] = 1.15 to 3.31), treatment with lumpectomy without radiation (OR = 3.27, 95% CI = 1.91 to 5.62), interval PBC presentation (OR = 2.01, 95% CI 1.28 to 3.16), and heterogeneously dense breasts on mammography (OR = 1.54, 95% CI = 1.01 to 2.36) as independent predictors of interval-invasive second breast cancers. Conclusions: PBC diagnosis and treatment characteristics contribute to variation in subsequent-interval second breast cancer risk. Consideration of these factors may be useful in developing tailored post-treatment imaging surveillance plans. PMID:25904721

  14. Enhanced tunable narrow-band THz emission from laser-modulated electron beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xiang, D.; Stupakov, G.; /SLAC

    2009-06-19

    We propose and analyze a scheme to generate enhanced narrow-band terahertz (THz) radiation through down-conversion of the frequency of optical lasers using laser-modulated electron beams. In the scheme the electron beam is first energy modulated by two lasers with wave numbers k{sub 1} and k2, respectively. After passing through a dispersion section, the energy modulation is converted to density modulation. Due to the nonlinear conversion process, the beam will have density modulation at wave number k = nk{sub 1} + mk{sub 2}, where n and m are positive or negative integers. By properly choosing the parameters for the lasers andmore » dispersion section, one can generate density modulation at THz frequency in the beam using optical lasers. This density-modulated beam can be used to generate powerful narrow-band THz radiation. Since the THz radiation is in tight synchronization with the lasers, it should provide a high temporal resolution for the optical-pump THz-probe experiments. The central frequency of the THz radiation can be easily tuned by varying the wavelength of the two lasers and the energy chirp of the electron beam. The proposed scheme is in principle able to generate intense narrow-band THz radiation covering the whole THz range and offers a promising way towards the tunable intense narrow-band THz sources.« less

  15. Post-KR Delay Intervals and Mental Practice: A Test of Adams' Closed Loop Theory

    ERIC Educational Resources Information Center

    Bole, Ronald

    1976-01-01

    The present study suggests that post-KR delay interval time or activity in the interval has little to do with learning on a self-paced positioning task, not ruling out that on ballistic tasks or more complex nonballistic tasks that a learner could make use of additional time or strategy. (MB)

  16. Comparison of Cardiorespiratory and Metabolic Responses in Kettlebell High-Intensity Interval Training Versus Sprint Interval Cycling.

    PubMed

    Williams, Brian M; Kraemer, Robert R

    2015-12-01

    The purpose of this study was to determine the effectiveness of a novel exercise protocol we developed for kettlebell high-intensity interval training (KB-HIIT) by comparing the cardiorespiratory and metabolic responses to a standard sprint interval cycling (SIC) exercise protocol. Eight men volunteered for the study and completed 2 preliminary sessions, followed by two 12-minute sessions of KB-HIIT and SIC in a counterbalanced fashion. In the KB-HITT session, 3 circuits of 4 exercises were performed using a Tabata regimen. In the SIC session, three 30-second sprints were performed, with 4 minutes of recovery in between the first 2 sprints and 2.5 minutes of recovery after the last sprint. A within-subjects' design over multiple time points was used to compare oxygen consumption (V[Combining Dot Above]O2), respiratory exchange ratio (RER), tidal volume (TV), breathing frequency (f), minute ventilation (VE), caloric expenditure rate (kcal·min), and heart rate (HR) between the exercise protocols. Additionally, total caloric expenditure was compared. A significant group effect, time effect, and group × time interaction were found for V[Combining Dot Above]O2, RER, and TV, with V[Combining Dot Above]O2 being higher and TV and RER being lower in the KB-HIIT compared with the SIC. Only a significant time effect and group × time interaction were found for f, VE, kcal·min, and HR. Additionally, total caloric expenditure was found to be significantly higher during the KB-HIIT. The results of this study suggest that KB-HIIT may be more attractive and sustainable than SIC and can be effective in stimulating cardiorespiratory and metabolic responses that could improve health and aerobic performance.

  17. The relationship between adjunctive drinking, blood ethanol concentration and plasma corticosterone across fixed-time intervals of food delivery in two inbred mouse strains.

    PubMed

    Ford, Matthew M; Steele, Andrea M; McCracken, Aubrey D; Finn, Deborah A; Grant, Kathleen A

    2013-11-01

    Schedules of intermittent food delivery induce excessive fluid intake, termed schedule-induced polydipsia (SIP), and hypothalamic-pituitary-adrenal (HPA) axis activation is important for the expression and maintenance of this adjunctive behavior. Previous work has focused on examining the relationship between water intake and plasma corticosterone (CORT) in rats at a single or a limited range of fixed time (FT) intervals. However, little remains known regarding SIP and the corresponding stress response (1) across the bitonic function that epitomizes adjunctive behavior, (2) when ethanol is the available fluid, and (3) when a species other than rat or multiple strains are studied. Here we report the findings from ethanol-preferring C57BL/6J (B6) and non-preferring DBA/2J (D2) mice serially exposed to progressively larger FT intervals (0 → 60 min) and given access to either water or a 5% (v/v) ethanol solution. Following 2 weeks of experience with each schedule, blood samples were collected at the conclusion of the last 60-min session to evaluate CORT and the blood ethanol concentration (BEC) achieved. While both strains exhibited a bitonic function of ethanol intake and BEC that peaked at or near a 5-min interval, only D2 mice showed a similar response with water. In contrast, CORT levels rose monotonically with incremental increases in the FT interval regardless of the strain examined or fluid type offered, indicating that glucocorticoid release likely reflects the aversive aspects of increasing intervals between reinforcement rather than engagement in adjunctive behavior. These findings also caution against the use of a single intensity stressor to evaluate the relationship between stress and ethanol intake, as the magnitude of stress appears to affect ethanol consumption in a non-linear fashion. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Effects of temporal laser profile on the emission spectra for underwater laser-induced breakdown spectroscopy: Study by short-interval double pulses with different pulse durations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tamura, Ayaka, E-mail: tamura.ayaka.88m@st.kyoto-u.ac.jp; Matsumoto, Ayumu; Nishi, Naoya

    We investigate the effects of temporal laser profile on the emission spectra of laser ablation plasma in water. We use short-interval (76 ns) double pulses with different pulse durations of the composing two pulses for the irradiation of underwater target. Narrow atomic spectral lines in emission spectra are obtained by the irradiation, where the two pulses are wide enough to be merged into a single-pulse-like temporal profile, while deformed spectra are obtained when the two pulses are fully separated. The behavior of the atomic spectral lines for the different pulse durations is consistent with that of the temporal profiles of themore » optical emission intensities of the plasma. All these results suggest that continuous excitation of the plasma during the laser irradiation for ∼100 ns is a key to obtain narrow emission spectral lines.« less

  19. Association of intraventricular mechanical dyssynchrony with response to cardiac resynchronization therapy in heart failure patients with a narrow QRS complex

    PubMed Central

    van Bommel, Rutger J.; Tanaka, Hidekazu; Delgado, Victoria; Bertini, Matteo; Borleffs, Carel Jan Willem; Ajmone Marsan, Nina; Holzmeister, Johannes; Ruschitzka, Frank; Schalij, Martin J.; Bax, Jeroen J.; Gorcsan, John

    2010-01-01

    Aims Current criteria for cardiac resynchronization therapy (CRT) are restricted to patients with a wide QRS complex (>120 ms). Overall, only 30% of heart failure patients demonstrate a wide QRS complex, leaving the majority of heart failure patients without this treatment option. However, patients with a narrow QRS complex exhibit left ventricular (LV) mechanical dyssynchrony, as assessed with echocardiography. To further elucidate the possible beneficial effect of CRT in heart failure patients with a narrow QRS complex, this two-centre, non-randomized observational study focused on different echocardiographic parameters of LV mechanical dyssynchrony reflecting atrioventricular, interventricular and intraventricular dyssynchrony, and the response to CRT in these patients. Methods and results A total of 123 consecutive heart failure patients with a narrow QRS complex (<120 ms) undergoing CRT was included at two centres. Several widely accepted measures of mechanical dyssynchrony were evaluated: LV filling ratio (LVFT/RR), LV pre-ejection time (LPEI), interventricular mechanical dyssynchrony (IVMD), opposing wall delay (OWD), and anteroseptal posterior wall delay with speckle tracking (ASPWD). Response to CRT was defined as a reduction ≥15% in left ventricular end-systolic volume at 6 months follow-up. Measures of dyssynchrony can frequently be observed in patients with a narrow QRS complex. Nonetheless, for LVFT/RR, LPEI, and IVMD, presence of predefined significant dyssynchrony is <20%. Significant intraventricular dyssynchrony is more widely observed in these patients. With receiver operator characteristic curve analyses, both OWD and ASPWD demonstrated usefulness in predicting response to CRT in narrow QRS patients with a cut-off value of 75 and 107 ms, respectively. Conclusion Mechanical dyssynchrony can be widely observed in heart failure patients with a narrow QRS complex. In particular, intraventricular measures of mechanical dyssynchrony may be useful in

  20. Precise measurement of ultra-narrow laser linewidths using the strong coherent envelope

    NASA Astrophysics Data System (ADS)

    Huang, Shihong; Zhu, Tao; Liu, Min; Huang, Wei

    2017-02-01

    Laser linewidth narrowing down to kHz or even Hz is an important topic in areas like clock synchronization technology, laser radars, quantum optics, and high-precision detection. Conventional decoherence measurement methods like delayed self-heterodyne/homodyne interferometry cannot measure such narrow linewidths accurately. This is because a broadening of the Gaussian spectrum, which hides the laser’s intrinsic Lorentzian linewidth, cannot be avoided. Here, we introduce a new method using the strong coherent envelope to characterize the laser’s intrinsic linewidth through self-coherent detection. This method can eliminate the effect of the broadened Gaussian spectrum induced by the 1/f frequency noise. We analyze, in detail, the relationship between intrinsic laser linewidth, contrast difference with the second peak and the second trough (CDSPST) of the strong coherent envelope, and the length of the delaying fiber. The correct length for the delaying fiber can be chosen by combining the estimated laser linewidth (Δfest) with a specific CDSPST (ΔS) to obtain the accurate laser linewidth (Δf). Our results indicate that this method can be used as an accurate detection tool for measurements of narrow or super-narrow linewidths.